  1. Effect of steel and teflon infusion catheters on subcutaneous adipose tissue blood flow and infusion counter pressure in humans

    DEFF Research Database (Denmark)

    Højbjerre, Lise; Skov-Jensen, Camilla; Kaastrup, Peter

    2009-01-01

    BACKGROUND: Subcutaneous tissue is an important target for drug deposition or infusion. A local trauma may induce alterations in local microcirculation and diffusion barriers with consequences for drug bioavailability. We examined the influence of infusion catheters' wear time on local...... microcirculation and infusion counter pressure. METHODS: One steel catheter and one Teflon (Dupont, Wilmington, DE) catheter were inserted in subcutaneous, abdominal adipose tissue (SCAAT) in 10 healthy, lean men. The catheters were infused with isotonic saline at a rate of 10 microL/h for 48 h. Another steel...... catheter and a Teflon catheter were inserted contralateral to the previous catheters after 48 h. The infusion counter pressure was measured during a basal infusion rate followed by a bolus infusion. The measurements during a basal rate infusion were repeated after the bolus infusion. Adipose tissue blood...

  2. Malfunctioning and infected tunneled infusion catheters: over-the-wire catheter exchange versus catheter removal and replacement.

    Science.gov (United States)

    Guttmann, David M; Trerotola, Scott O; Clark, Timothy W; Dagli, Mandeep; Shlansky-Goldberg, Richard D; Itkin, Maxim; Soulen, Michael C; Mondschein, Jeffrey I; Stavropoulos, S William

    2011-05-01

    To compare the safety and effectiveness of over-the-wire catheter exchange (catheter-exchange) with catheter removal and replacement (removal-replacement) at a new site for infected or malfunctioning tunneled infusion catheters. Using a quality assurance database, 61 patients with tunneled infusion catheters placed during the period July 2001 to June 2009 were included in this study. Patients receiving hemodialysis catheters were excluded. Catheter-exchange was performed in 25 patients, and same-day removal-replacement was performed in 36 patients. Data collected included demographic information, indication for initial catheter placement and replacement, dwell time for the new catheter, and ultimate fate of the new device. Statistical comparisons between the two cohorts were analyzed using the Kaplan-Meier technique and Fisher exact test. Catheters exchanged over the wire remained functional without infection for a median of 102 days (range, 2-570 days), whereas catheters removed and replaced were functional for a median 238 days (range, 1-292 days, P = .12). After catheter replacement, there were 11 instances of subsequent infection in the catheter-exchange group and 7 instances in the removal-replacement cohort, accounting for infection rates of 4.4 and 2.3 per 1,000 catheter days (P = .049). Patients in the catheter-exchange group had 3.2 greater odds of infection compared with patients in the removal-replacement group. Five malfunction events occurred in each group, accounting for 2.0 and 1.7 malfunctions per 1,000 catheter days in the catheter-exchange and removal-replacement groups (P = .73). Catheter-exchange of tunneled infusion catheters results in a higher infection rate compared with removal-replacement at a new site. The rate of catheter malfunction is not significantly different between the two groups. Catheter-exchange is an alternative for patients with tunneled infusion catheters who have limited venous access, but this technique should not be

  3. Analog experiment of transarterial catheter hyperthermic infusion in vitro

    International Nuclear Information System (INIS)

    Fan Shufeng Li Zheng; Gu Weizhong; Ru Fuming

    2006-01-01

    Objective: To investigate the factors related to the heating effect by transarterial catheter hyperthermic infusion with the evaluation of the feasibility in controlling the tumor temperature. Methods: Infusing 55-68 degree C liquid at the speed of 10-40 ml/min through 6F, 5F or 3F catheter with different length respectively under the similar clinical condition. The liquid temperature at the terminal exit of the catheter was measured with a digital thermometer. The factors related to the liquid temperature at the exit of the catheter were analyzed by multiple regression analysis. Results: The infusion temperature , rate and the catheter length were the main related factors to the liquid temperature at the exit of the catheter as the condition similar in clinical use. When 60-65 degree C liquid was infused at the rate of 20-40 ml/min through 5F catheter with length of 80 cm, the mean and 95% confident interval of the liquid temperature at the catheter exit were (47.55±0.44) degree C and 44.61-48.49 degree C respectively. Conclusions: The liquid temperature at the exit of infusion catheter can be regulated and controlled through adjusting the liquid perfusion temperature and speed. (authors)

  4. Low-angled peripheral intravenous catheter tip placement decreases phlebitis.

    Science.gov (United States)

    Tanabe, Hidenori; Murayama, Ryoko; Yabunaka, Koichi; Oe, Makoto; Takahashi, Toshiaki; Komiyama, Chieko; Sanada, Hiromi

    2016-11-02

    Peripheral intravenous catheters (PIVCs) are frequently removed due to phlebitis. We hypothesized that catheters made of polyurethane, which is more flexible than Teflon, would decrease phlebitis, and that flexibility could be estimated by measuring the catheter-tip angle. Ultrasonography in two groups of patients with different catheter types was then used to compare catheter-tip angles and phlebitis. Observational studies were carried out at a medical ward in a university hospital. Infusion therapy was administered to one group of patients in 2014 using Teflon catheters (control group, n = 200), and to another group of patients in 2015 using polyurethane catheters (investigational group, n = 207). The symptoms were assessed according to a scale developed by the Infusion Nurses Society. Long-axis ultrasonography images taken immediately before catheter removal were used to measure the angle between the central line of the catheter within 2 mm from the distal point and a tangent to the vessel wall. There were no significant differences between the two groups with respect to sex, age, and medical diagnosis. In the control and investigational groups, the rates of phlebitis were 37% (73/200) and 17% (36/207), respectively (pPhlebitis occurred more frequently when the catheter-tip was placed at angle >5.8°. The frequency of phlebitis was lower in the polyurethane, in which the catheter was placed at lower angle, almost parallel to the vessel. Our results will aid in developing new catheters and in improving PIVC-securement techniques.

  5. Stabilization of a percutaneously implanted port catheter system for hepatic artery chemotherapy infusion

    International Nuclear Information System (INIS)

    Shindoh, Noboru; Ozaki, Yutaka; Kyogoku, Shinsuke; Yamana, Daigo; Sumi, Yukiharu; Katayama, Hitoshi

    1999-01-01

    A port catheter system for hepatic artery infusion chemotherapy was implanted percutaneously via the left subclavian artery in 41 patients for treatment of unresectable liver metastases. The catheter tip was inserted into the gastroduodenal artery (GDA), the end hole was occluded with a guidewire fragment, and a side-hole for infusion was positioned at the bifurcation of the proper hepatic artery and the GDA. The GDA was embolized with steel coils around the infusion catheter tip via a transfemoral catheter. This procedure is designed to reduce the incidence of hepatic artery occlusion and infusion catheter dislocation.

  6. Assessment of right liver graft perfusion effectiveness between one and two-catheter infusion methods.

    Science.gov (United States)

    Jung, Bo-Hyun; Hwang, Shin; Ha, Tae-Yong; Song, Gi-Won; Jung, Dong-Hwan; Kim, Ki-Hun; Ahn, Chul-Soo; Moon, Deok-Bog; Park, Gil-Chun; Kang, Sung-Hwa; Yoon, Young-In; Lee, Sung-Gyu

    2014-05-01

    Conventional graft perfusion method using one small-caliber catheter takes a relatively long time for right liver graft perfusion, thus some modification is needed. In this study, we intended to assess the effectiveness of right liver graft perfusion methods through comparison of different infusion catheters. The study consisted of two parts including one bench experiment to obtain data of hydraulic infusion and one clinical trial of 40 cases on graft perfusion with one- versus two-catheter infusion methods. These two graft infusion methods were compared in terms of the perfusion time and washing-out efficiency. At bench experiment, the infusion flow rate and infusion pressure were 3.3 ml/sec and 1.9 cmH20 in one blood transfusion catheter group, and 11.7 ml/sec and 3.1 cmH20 in single transurethral resection of prostate irrigation catheter group, and 6.6 ml/sec and 2.0 cmH20 in two blood transfusion catheters group, respectively. In clinical trial with 40 right liver grafts, two-catheter group had a shorter graft portal perfusion time for the first 2 L of histidine-tryptophan-ketoglutarate (HTK) solution than the conventional one-catheter group (375±25 seconds vs. 662±34 seconds; p=0.001) and a lower rate of incomplete blood washing-out after the initial 2 L portal perfusion (40% vs. 85%; p=0.03). The two-catheter infusion method appears to be more effective than the conventional one-catheter infusion method for right liver graft perfusion at the back table. Large size of right liver grafts seems to be its good indication.

  7. Digital subtraction angiography of inferior gluteal artery through the infusion catheter of chemotherapy for bladder cancer

    International Nuclear Information System (INIS)

    Ishikawa, Satoru; Noguchi, Ryosuke; Kanoh, Shori; Shimazui, Toru; Uchida, Katsunori; Nemoto, Ryosuke; Koiso, Kenkichi

    1987-01-01

    More than fifty patients of invasive bladder cancer had been treated by selective intra-arterial chemotherapy through the inferior or superior gluteal arteries. The distribution of infused drugs had been evaluated by RI-angiography through a thin arterial infusion catheter. This time we performed digital subtraction angiography (DSA) through an infusion catheter in order to know the precise distribution of infused materials in seven patients with locally advanced bladder cancer. Pharmaco-DSA with norepinephrine was also done in four patients. Satisfactory spatial and contrast resolution were gained in four patients and pharmaco-DSA showed better quality. In our experience DSA through intra-arterial infusion catheter was a useful procedure in the evaluation of distribution of infused drugs. (author)

  8. Catheter Occlusion in Home Infusion: The Influence of Needleless Connector Design on Central Catheter Occlusion.

    Science.gov (United States)

    Williams, Ann

    Thrombotic catheter occlusion is a common complication associated with central venous catheters (CVCs). A wide variety of needleless connectors that differ greatly in design and function are available for use with CVCs; however, there are a limited number of studies comparing the catheter occlusion rate associated with differently designed needleless connectors. This retrospective observational study compared occlusion rates associated with a split-septum neutral-displacement needleless connector versus those of a solid-surface neutral-reflux needleless connector in patients undergoing home infusion therapy. The neutral-reflux needleless connector was associated with a significant reduction in occlusion rate and thrombolytic use versus the neutral-displacement needleless connector.

  9. Influence of the catheter-top-position upon the distribution pattern of continuous intra-arterially infused chemotherapeutic agent

    International Nuclear Information System (INIS)

    Ichinohe, Hyobu

    1980-01-01

    The whole body scanning showed the distribution pattern of infused drug in continuous intra-arterially infused chemotherapy by using a gamma camera and infused RI (sup(99m)Tc-MAA) from catheter. I measured the whole body scanning counts without shield (A) and with lead shield (B) on ROI and natural back ground counts (BG). Then I calculated the distribution ratio on ROI as following. [(A-B)/(A-BG)] x 100(%). It was easy to find a certain relation between the catheter-top-position and the distribution ratio. As a result of investigating data, there were about 4 catheter-top-positions in aorta. Case by case, we putted the catheter-top in better position and prevented technical side effects and measured roughly total dose on ROI. (author)

  10. Clinical nursing of pelvic neoplasm treated with infusion chemotherapy by using an anti-reflux arterial port-catheter system

    International Nuclear Information System (INIS)

    Xing Li; Yuan Chanjuan

    2011-01-01

    Objective: To discuss the clinical nursing care for patients with pelvic neoplasm who were treated with infusion chemotherapy by using an anti-reflux arterial port-catheter system. Methods: After the implantation of an anti-reflux arterial port-catheter system was successfully completed, intra-arterial infusion chemotherapy was carried out in 17 patients with pelvic neoplasm and the infusion chemotherapy was repeated for several times. The pre-procedural clinical nursing care was well done and the technique of proper placement was well grasped. The side effects of chemotherapy drugs and complications were dealt with in time. Medical orientation at discharge time included the protection methods for port-catheter system. Results: Seventeen patients received infusion chemotherapy successfully several times (ranged from 3 to 8 times) with a scheduled regular interval time. No severe complications occurred. No catheter leakage nor obvious irritation and compression symptoms of local skin developed during infusion period. Of the 17 patients, 6 had a complete response, 9 achieved a partial response, while the remaining 2 failed to respond. Conclusion: In accordance with characteristics of infusion chemotherapy by using an anti-reflux arterial port-catheter system, the reasonable and effective nursing care is important to guarantee the achievement of a successful performance and a satisfactory therapeutic result. (authors)

  11. Catheter Migration After Implantationan Intrathecal Baclofen Infusion Pump for Severe Spasticity: A Case Report

    Directory of Open Access Journals (Sweden)

    Tung-Chou Li

    2008-09-01

    Full Text Available We report a case of intrathecal baclofen infusion pump implantation complicated by migration of the catheter tip. A 55-year-old man required an intrathecal baclofen infusion for severe spasticity 4 years after a cervical spinal cord injury with incomplete tetraparesis. Twelve months after initial implantation of the device, the patient began to experience a recurrence of trunk tightness and spasticity. Subsequent X-ray and computed tomography evaluations of the catheter system revealed pooling of contrast medium outside of the intrathecal distribution in the lumbar subcutaneous region of the back and therefore migration of the pump catheter tip. At surgical revision, emphasis was placed on minimizing the length of catheter outside of the spine and securing the catheter in the supraspinous fascia with a right-angled anchor. The distance between the anchors and the entry point of the catheter into the supraspinous fascia was also reduced to prevent slipping when the patient bends forward. After surgery, the patient's spasticity improved and, 1 year later, he has experienced no further complications during follow-up, requiring an average baclofen dose of 150 mg/day. Here, we describe several surgical methods intended to secure the intrathecal catheter and prevent catheter migration. Other complications related to catheter failure are also highlighted.

  12. Venipuncture versus peripheral catheter: do infusions alter laboratory results?

    Science.gov (United States)

    Hambleton, Victoria Lerma; Gómez, Ignacio Arribas; Andreu, Francisco A Bernabeu

    2014-01-01

    Our aim was to evaluate the equivalence between analytic parameters from blood samples obtained from a saline solution lock device used for the infusion of drugs and those from venipuncture. In our emergency department, patients bearing a saline solution lock device have blood extracted by venipuncture to avoid possible contamination of the sample. Adults from the emergency department with a saline solution lock device who required laboratory tests were selected as candidates for this cross-sectional observational study. Infusions were halted and flushed with 0.9% saline solution; 2 minutes later, 2 mL of blood was drawn and discarded, and the corresponding laboratory tubes were filled. Immediately after, another sample was withdrawn from the opposite extremity by venipuncture. Both samples were analyzed for hematology, biochemistry, venous blood gases, and coagulation parameters. Concordance was evaluated by use of the intraclass correlation coefficient with its 95% confidence intervals; Bland-Altman plots were used to illustrate the percentage of samples with differences exceeding 2 SDs. The mean differences were also checked to detect those exceeding the laboratory's systematic error. An intraclass correlation coefficient of over 0.9 was achieved for all parameters except for pH, partial pressure of carbon dioxide, and partial pressure of oxygen. Differences of over 2 SDs were found in fewer than 10% of all parameters. None of them exceeded 3 SDs, except for pH and venous blood gases. All parameters showed differences below the laboratory's accepted systematic error except for pH and venous blood gases. Blood samples extracted from a peripheral catheter with or without drug infusions are valid for the analysis of hematology, biochemistry, and coagulation parameters but not for venous blood gases. Nurses should know the benefits of using an existing peripheral catheter for drawing blood samples for laboratory analysis even when infusing commonly used drugs

  13. Prostaglandin synthesis can be inhibited locally by infusion of NSAIDS through microdialysis catheters in human skeletal muscle

    DEFF Research Database (Denmark)

    Mikkelsen, Ulla Ramer; Helmark, Ida Carøe; Kjaer, Michael

    2008-01-01

    of nonsteroidal anti-inflammatory drugs (NSAIDs). However, to study the local role of prostaglandins, the formation of prostaglandins within the tissue must be controlled. Microdialysis enables determination of local concentrations of water-soluble substances within the tissue. In the present study......, the microdialysis method was used to infuse NSAIDs locally into human skeletal muscles producing a local block of prostaglandin formation. In addition, the graded blockade at various distances from the infusion site within the muscle during rest, exercise and recovery was determined. Microdialysis was performed...... in thigh muscles (vastus lateralis muscle) in six healthy men. One of the microdialysis catheters was used to block prostaglandin synthesis by infusion of the NSAID indomethacin. Additional catheters were placed 1 and 4 cm away from the infusion and in the contralateral leg (working control). Following 2 h...

  14. Novel monorail infusion catheter for volumetric coronary blood flow measurement in humans: in vitro validation.

    Science.gov (United States)

    van 't Veer, Marcel; Adjedj, Julien; Wijnbergen, Inge; Tóth, Gabor G; Rutten, Marcel C M; Barbato, Emanuele; van Nunen, Lokien X; Pijls, Nico H J; De Bruyne, Bernard

    2016-08-20

    The aim of this study is to validate a novel monorail infusion catheter for thermodilution-based quantitative coronary flow measurements. Based on the principles of thermodilution, volumetric coronary flow can be determined from the flow rate of a continuous saline infusion, the temperature of saline when it enters the coronary artery, and the temperature of the blood mixed with the saline in the distal part of the coronary artery. In an in vitro set-up of the systemic and coronary circulation at body temperature, coronary flow values were varied from 50-300 ml/min in steps of 50 ml/min. At each coronary flow value, thermodilution-based measurements were performed at infusion rates of 15, 20, and 30 ml/min. Temperatures and pressures were simultaneously measured with a pressure/temperature sensor-tipped guidewire. Agreement of the calculated flow and the measured flow as well as repeatability were assessed. A total of five catheters were tested, with a total of 180 measurements. A strong correlation (ρ=0.976, p<0.0001) and a difference of -6.5±15.5 ml/min were found between measured and calculated flow. The difference between two repeated measures was 0.2%±8.0%. This novel infusion catheter used in combination with a pressure/temperature sensor-tipped guidewire allows accurate and repeatable absolute coronary flow measurements. This opens a window to a better understanding of the coronary microcirculation.

  15. Large-volume paracentesis with indwelling peritoneal catheter and albumin infusion: a community hospital study

    Directory of Open Access Journals (Sweden)

    Daniel K. Martin

    2016-10-01

    Full Text Available Background: The management of ascites can be problematic. This is especially true in patients with diuretic refractory ascites who develop a tense abdomen. This often results in hypotension and decreased venous return with resulting renal failure. In this paper, we further examine the risks and benefits of utilizing an indwelling peritoneal catheter to remove large-volume ascites over a 72-h period while maintaining intravascular volume and preventing renal failure. Methods: We retrospectively reviewed charts and identified 36 consecutive patients undergoing continuous large-volume paracentesis with an indwelling peritoneal catheter. At the time of drain placement, no patients had signs or laboratory parameters suggestive of spontaneous bacterial peritonitis. The patients underwent ascitic fluid removal through an indwelling peritoneal catheter and were supported with scheduled albumin throughout the duration. The catheter was used to remove up to 3 L every 8 h for a maximum of 72 h. Regular laboratory and ascitic fluid testing was performed. All patients had a clinical follow-up within 3 months after the drain placement. Results: An average of 16.5 L was removed over the 72-h time frame of indwelling peritoneal catheter maintenance. The albumin infusion utilized correlated to 12 mg/L removed. The average creatinine trend improved in a statistically significant manner from 1.37 on the day of admission to 1.21 on the day of drain removal. No patients developed renal failure during the hospital course. There were no documented episodes of neutrocytic ascites or bacterial peritonitis throughout the study review. Conclusion: Large-volume peritoneal drainage with an indwelling peritoneal catheter is safe and effective for patients with tense ascites. Concomitant albumin infusion allows for maintenance of renal function, and no increase in infectious complications was noted.

  16. Novel monorail infusion catheter for volumetric coronary blood flow measurement in humans: in vitro validation

    NARCIS (Netherlands)

    van 't Veer, M.; Adjedj, J.; Wijnbergen, I.; Tóth, G.G.; Rutten, M.C.M.; Barbato, E.; van Nunen, L.X.; Pijls, N.H.J.; de Bruyne, B.

    2016-01-01

    AIMS: The aim of this study is to validate a novel monorail infusion catheter for thermodilution-based quantitative coronary flow measurements. METHODS AND RESULTS: Based on the principles of thermodilution, volumetric coronary flow can be determined from the flow rate of a continuous saline

  17. Incidence of phlebitis associated with the use of peripheral IV catheter and following catheter removal

    Directory of Open Access Journals (Sweden)

    Janete de Souza Urbanetto

    Full Text Available ABSTRACT Objective: to investigate the incidence of phlebitis and its association with risk factors when using peripheral IV catheters (PIC and following their removal - (post-infusion phlebitis in hospitalized adults. Method: a cohort study of 171 patients using PIC, totaling 361 punctures. Sociodemographic variables and variables associated with the catheter were collected. Descriptive and analytical statistical analyses were performed. Results: average patient age was 56.96 and 51.5% of the sample population was male. The incidence of phlebitis was 1.25% while using PIC, and 1.38% post-infusion. The incidence of phlebitis while using PIC was associated with the length of time the catheter remained in place, whereas post-infusion phlebitis was associated with puncture in the forearm. Ceftriaxone, Clarithromycin and Oxacillin are associated with post-infusion phlebitis. Conclusions: this study made it possible to investigate the association between risk factors and phlebitis during catheter use and following its removal. The frequency of post-infusion phlebitis was larger than the incidence of phlebitis with the catheter in place, with Phlebitis Grade III and II being the most frequently found in each of these situations, respectively. Aspects related to post-infusion phlebitis can be explained, given the limited number of studies addressing this theme from this perspective.

  18. Superselective intra-arterial infusion via the superficial temporal artery and occipital artery for gingival carcinoma of the mandible. Simultaneous catheter placement to the maxillary artery and facial artery

    International Nuclear Information System (INIS)

    Iwai, Toshinori; Mitsudo, Kenji; Fukui, Takafumi

    2009-01-01

    Superselective intra-arterial infusion via the superficial temporal artery (STA) has become useful for oral cancer. Approaching via the occipital artery (OA) enables superselective intra-arterial infusion when catheter placement via the STA is impossible. Therefore, simultaneous catheter placement via the STA and OA is possible. We report a surgical method of simultaneous catheter placement via the STA and OA to achieve retrograde superselective intra-arterial infusion for gingival carcinoma of the mandible. Preoperatively, three-dimensional computed tomography angiography was performed to identify the route of the external carotid artery and branches such as the STA, OA, maxillary artery, and facial artery (FA). Thirteen patients with mandibular gingival cancer underwent catheter placement via the STA and OA under local anesthesia. Catheter placement via the STA and OA was superselectively successful in all the patients. The mean operating time was 150.8 min. Catheter placed to the FA via the OA was dislocated during the treatment in one patient, and so the catheter was replaced. This method is useful to enable superselective intra-arterial chemotherapy to the whole gingival carcinoma of the mandible from the start of treatment compared with approaching via the STA. (author)

  19. Bilateral transversus abdominis plane (TAP) block with 24 hours ropivacaine infusion via TAP catheters

    DEFF Research Database (Denmark)

    Petersen, Pernille L; Hilsted, Karen L; Dahl, Jørgen B

    2013-01-01

    The analgesic effect of a TAP block has been investigated in various surgical settings. There are however limited information about block level and block duration. Furthermore, there is a lack of information about continuous TAP block after ultrasound-guided posterior TAP blocks.The aim of this d...... of this double-blind randomized study was therefore to investigate the effect of an ultrasound-guided posterior TAP block with 24 hours local anesthetic infusion via a TAP catheter....

  20. Use of monorail PTCA balloon catheter for local drug delivery.

    Science.gov (United States)

    Trehan, Vijay; Nair, Girish M; Gupta, Mohit D

    2007-01-01

    We report the use of monorail coronary balloon as an infusion catheter to give bailout abciximab selectively into the site of stent thrombosis as an adjunct to plain old balloon angioplasty (POBA) in a patient of subacute stent thrombosis of the left anterior descending coronary artery. The balloon component (polyamide material) of the monorail balloon catheter was shaved off the catheter so that abciximab injected through the balloon port of the catheter exited out the shaft of the balloon catheter at the site from where the balloon material was shaved off. We believe that selective infusion with abciximab along with POBA established antegrade flow and relieved the patient's ischemia. In the absence of essential hardware to give intracoronary drugs in an emergency situation, one may employ our technique of infusion through a monorail balloon catheter after shaving the balloon component from the catheter.

  1. Association between continuous peripheral i.v. infusion of 3% sodium chloride injection and phlebitis in adults.

    Science.gov (United States)

    Meng, Lina; Nguyen, Cherwyn M; Patel, Samit; Mlynash, Michael; Caulfield, Anna Finley

    2018-03-01

    One institution's experience with use of peripheral i.v. (PIV) catheters for prolonged infusions of 3% sodium chloride injection at rates up to 100 mL/hr is described. A prospective, observational, 13-month quality assurance project was conducted at an academic medical center to evaluate frequencies of patient and catheter phlebitis among adult inpatients who received both an infusion of 3% sodium chloride injection for a period of ≥4 hours through a dedicated PIV catheter and infusions of routine-care solutions (RCSs) through separate PIV catheters during the same hospital stay. Sixty patients received PIV infusions through a total of 291 catheters during the study period. The majority of patients (78%) received infusions of 3% sodium chloride injection for intracranial hypertension, with 30% receiving such infusions in the intensive care unit. Phlebitis occurred in 28 patients (47%) during infusions of 3% sodium chloride and 26 patients (43%) during RCS infusions ( p = 0.19). Catheter phlebitis occurred in 73 catheters (25%), with no significant difference in the frequencies of catheter phlebitis with infusion of 3% sodium chloride versus RCSs (30% [32 of 106 catheters]) versus 22% [41 of 185 catheters]), p = 0.16). Patient and catheter phlebitis rates were not significantly different with infusions of 3% sodium chloride injection versus RCSs, suggesting that an osmolarity cutoff value of 900 mOsm/L for peripheral infusions of hypertonic saline solutions may not be warranted. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  2. Continuous insulin administration via complex central venous catheter infusion tubing is another risk factor for blood glucose imbalance. A retrospective study.

    Science.gov (United States)

    Maury, Eric; Vitry, Paola; Galbois, Arnauld; Ait-Oufella, Hafid; Baudel, Jean-Luc; Guidet, Bertrand; Offenstadt, Georges

    2012-06-14

    We assessed the potential impact of infusion tubing on blood glucose imbalance in ICU patients given intensive insulin therapy (IIT). We compared the incidence of blood glucose imbalance in patients equipped, in a nonrandomized fashion, with either conventional tubing or with a multiport infusion device. We retrospectively analyzed the nursing files of 35 patients given IIT through the distal line of a double-lumen central venous catheter. A total of 1389 hours of IIT were analyzed for occurrence of hypoglycemic events [defined as arterial blood glucose below 90 mg/dL requiring discontinuation of insulin]. Twenty-one hypoglycemic events were noted (density of incidence 15 for 1000 hours of ITT). In 17 of these 21 events (81%), medication had been administered during the previous hour through the line connected to the distal lumen of the catheter. Conventional tubing use was associated with a higher density of incidence of hypoglycemic events than multiport infusion device use (23 vs. 2 for 1,000 hours of IIT; rate ratio = 11.5; 95% confidence interval, 2.71-48.8; p tubing carrying other medications can lead to the delivery of significant amounts of unscheduled products. Hypoglycaemia observed during IIT could be related to this phenomenon. The use of a multiport infusion device with a limited dead volume could limit hypoglycemia in patients on IIT.

  3. Local Intravascular Drug Delivery: In Vitro Comparison of Three Catheter Systems

    International Nuclear Information System (INIS)

    Alfke, Heiko; Wagner, Hans-Joachim; Calmer, Christian; Klose, Klaus Jochen

    1998-01-01

    Purpose: The aim of this in vitro study was to compare different catheter systems for local drug delivery with respect to the penetration depth of a biotin marker solution delivered into the vessel wall. Methods: Post-mortem carotid arteries from pigs were locally infused with a biotin solution using three different catheter systems. With all catheters (microporous balloon catheter, hydrogel-coated balloon catheter, and spiral balloon catheter) we used the same pressure of 405 kPa (4 atm) and infusion times of 60, 90, and 300 sec. After infusion the arteries were histologically prepared and stained using a biotin-specific method. With a light microscope an observer, blinded to the catheter type, scored the amount of biotin within the vessel wall, measured as staining intensity, and the penetration depth of the biotin. Results: Delivery with the hydrogel-coated balloon catheter was limited to the intima and the innermost parts of the media. The spiral balloon and microporous balloon catheter showed both a deeper penetration and a larger amount of delivered biotin compared with the hydrogel catheter, with a slightly deeper penetration using the microporous catheter. The penetration depth showed a correlation with infusion time for the spiral balloon and microporous catheters, but not for the hydrogel-coated catheter. Conclusion: Different catheter designs lead to different patterns of local drug delivery. The differences in penetration depth and amount of the substance delivered to the vessel wall should be known and might be useful for targeting specific areas within the vessel wall

  4. Heparinization of alimentation solutions administered through peripheral veins in premature infants: a controlled study.

    Science.gov (United States)

    Alpan, G; Eyal, F; Springer, C; Glick, B; Goder, K; Armon, J

    1984-09-01

    A randomized controlled study was done to determine whether the addition of heparin (1 U/mL) to peripheral intravenous alimentation solutions would affect the incidence of phlebitis and duration of patency of intravenous catheters in premature infants. Twenty-two-gauge Teflon catheters were uniformly used. One hundred five catheters infused with heparin were placed in 13 infants, and 122 catheters were placed in the control group of 13 infants. The time, nature, and incidence of complications were noted for each infusion site. Infusion of heparin was found to double the duration of patency of intravenous catheters and to reduce significantly the incidence of phlebitis. No complications related to the administration of heparin were noted. Heparinization of intravenous alimentation solutions should therefore be considered in premature infants as a means of reducing the work load and incidence of complications associated with peripheral lines.

  5. Temperature-controlled irrigated tip radiofrequency catheter ablation

    DEFF Research Database (Denmark)

    Petersen, H H; Chen, X; Pietersen, Adrian

    1998-01-01

    INTRODUCTION: In patients with ventricular tachycardias due to structural heart disease, catheter ablation cures radiofrequency ablation. Irrigated tip radiofrequency ablation using power control and high infusion rates enlarges lesion......: We conclude that temperature-controlled radiofrequency ablation with irrigated tip catheters using low target temperature and low infusion rate enlarges lesion size without increasing the incidence of cratering and reduces coagulum formation of the tip....

  6. [Injection Pressure Evaluation of the New Venous Catheter with Side Holes for Contrast-enhanced CT/MRI].

    Science.gov (United States)

    Fukuda, Junya; Arai, Keisuke; Miyazawa, Hitomi; Kobayashi, Kyouko; Nakamura, Junpei; Suto, Takayuki; Tsushima, Yoshito

    2018-01-01

    The simulation study was conducted for the new venous catheter with side holes of contrast-enhanced computed tomography (CT) and magnetic resonance imaging (MRI) to evaluate the infusion pressure on four contrast media and several injection speeds. All infusion pressure of the new venous catheter with side holes were less than 15 kg/cm 2 as limitation of extension tube and also reduced the infusion pressure by 15% at the maximum compared to the catheter with single hole. The results suggest that the new venous catheter with side holes can reduce the infusion pressure by power injection of contrast-enhanced CT and MRI.

  7. Effect of insulin catheter wear-time on subcutaneous adipose tissue blood flow and insulin absorption in humans

    DEFF Research Database (Denmark)

    Clausen, Trine Schnedler; Kaastrup, Peter; Stallknecht, Bente

    2009-01-01

    blood flow (ATBF) and absorption of the rapid-acting insulin analog insulin aspart over a period of 4 days. METHODS: Teflon insulin catheters (Medtronic, Minneapolis, MN) were inserted into the abdominal SAT of 10 healthy men without diabetes (mean +/- SEM age, 23.0 +/- 1.1 years; body mass index, 22...... +/- 3 min on day 0 to 45 +/- 4 min on day 4 (P = 0.019). Neither peak plasma concentration nor area under the curve of insulin aspart changed significantly. CONCLUSIONS: Insertion of a Teflon insulin catheter into the SAT results in increased ATBF and faster absorption of insulin aspart in a period of 4...

  8. Continuous infusion versus intermittent flushing to prevent loss of function of peripheral intravenous catheters used for drug administration in newborn infants.

    Science.gov (United States)

    Flint, A; McIntosh, D; Davies, M W

    2005-10-19

    The use of peripheral intravenous cannulae is common in newborn babies. Many of them require an intravenous line only for medications and not for fluid. Currently there is little uniformity in methods used to maintain cannula patency. The object of this review was to determine which method was better for maintaining intravenous lines used in neonates for intravenous medication only: intermittent flushing or continuous infusion We searched The Cochrane Central Register of Controlled Trials (CENTRAL, The Cochrane Library, Issue 2, 2004), CINAHL (from 1982 to June 2004) and MEDLINE (from 1966 to June 2004) . Randomised controlled trials comparing continuous infusion to intermittent flushing to maintain patency of intravenous cannulas. Units of randomisation might include individual catheters or individual babies. Three reviewers independently assessed trial quality and extracted data. Two studies were eligible for inclusion. In one study only one of our primary outcomes was available: the duration of cannula patency for the first cannula used per infant was slightly longer in the continuous infusion group, but not significantly so, with a mean difference of -4.3 hours (95% CI -18.2 to 9.7). In the second study, only one of our primary outcomes was available: the mean (SD) number cannulas used per infant in the first 48 hours was less in the intermittent flush group with a mean difference of -0.76 cannulas (95% CI -1.37 to -0.15). No results were available for any of our other primary outcomes: in the published report, results were reported per catheter rather than per infant, a number of infants received more than one intravenous catheter (39 infants received an unknown number of catheters). The overall duration of cannula patency was significantly longer in the intermittent flush group with a mean duration of patency in the intermittent flush group of 2.1 days (SD 1.0) compared with the continuous infusion group where the mean duration of patency was 1.0 days (SD 0

  9. Intravascular (catheter) MR imaging

    International Nuclear Information System (INIS)

    Cohen, A.M.; Hurst, G.C.; Katz, D.E.; Dverk, J.L.; Wiesen, E.J.; Czerski, L.W.; Malaya, R.; Bellon, E.M.

    1989-01-01

    Intravascular MR probes allow excellent spatial resolution and have the potential to detect arterial wall microstructure. Ultrasonic intravascular probes suggest that detailed morphologic information can assist clinical decision making. Catheter MR probes of 2--7 mm outside diameter (OD) were built of copper wire, Teflon, and parts from standard commercial catheters. The probes were connected to the surface coil receiver input of our Picker VISTA 2055HP 1.5-T imaging system. The extant (linear) body coil was used for transmit. Phantoms were constructed of coaxial glass MR tubes, filled with doped water. Watanabe rabbit aorta and human autopsy iliac artery specimens were examined within 4 hours of excision or stored by freezing. In vivo iliac arteries in dogs under general anesthesia were imaged, with percutaneous placement of the probe. Results are presented

  10. Should in-line filters be used in peripheral intravenous catheters to prevent infusion-related phlebitis? A systematic review of randomized controlled trials.

    Science.gov (United States)

    Niël-Weise, Barbara S; Stijnen, Theo; van den Broek, Peterhans J

    2010-06-01

    In this systematic review, we assessed the effect of in-line filters on infusion-related phlebitis associated with peripheral IV catheters. The study was designed as a systematic review and meta-analysis of randomized controlled trials. We used MEDLINE and the Cochrane Controlled Trial Register up to August 10, 2009. Two reviewers independently assessed trial quality and extracted data. Data on phlebitis were combined when appropriate, using a random-effects model. The impact of the risk of phlebitis in the control group (baseline risk) on the effect of in-line filters was studied by using meta-regression based on the bivariate meta-analysis model. The quality of the evidence was determined by using the GRADE (Grading of Recommendations Assessment, Development, and Evaluation) method. Eleven trials (1633 peripheral catheters) were included in this review to compare the effect of in-line filters on the incidence of phlebitis in hospitalized patients. Baseline risks across trials ranged from 23% to 96%. Meta-analysis of all trials showed that in-line filters reduced the risk of infusion-related phlebitis (relative risk, 0.66; 95% confidence interval, 0.43-1.00). This benefit, however, is very uncertain, because the trials had serious methodological shortcomings and meta-analysis revealed marked unexplained statistical heterogeneity (P < 0.0000, I(2) = 90.4%). The estimated benefit did not depend on baseline risk. In-line filters in peripheral IV catheters cannot be recommended routinely, because evidence of their benefit is uncertain.

  11. Catheter indwell time and phlebitis development during peripheral intravenous catheter administration.

    Science.gov (United States)

    Pasalioglu, Kadriye Burcu; Kaya, Hatice

    2014-07-01

    Intravenous catheters have been indispensable tools of modern medicine. Although intravenous applications can be used for a multitude of purposes, these applications may cause complications, some of which have serious effects. Of these complications, the most commonly observed is phlebitis. This study was conducted to determine the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. This study determined the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. The study included a total of 103 individuals who were administered 439 catheters and satisfied the study enrollment criteria at one infectious diseases clinic in Istanbul/Turkey. Data were compiled from Patient Information Forms, Peripheral Intravenous Catheter and Therapy Information Forms, reported grades based on the Visual Infusion Phlebitis Assessment Scale, and Peripheral Intravenous Catheter Nurse Observation Forms. The data were analyzed using SPSS. Results : The mean patient age was 53.75±15.54 (standard deviation) years, and 59.2% of the study participants were men. Phlebitis was detected in 41.2% of peripheral intravenous catheters, and the rate decreased with increased catheter indwell time. Analyses showed that catheter indwell time, antibiotic usage, sex, and catheterization sites were significantly associated with development of phlebitis. The results of this study show that catheters can be used for longer periods of time when administered under optimal conditions and with appropriate surveillance.

  12. A randomized controlled trial of foley catheter, extra-amniotic saline infusion and prostaglandin e2 suppository for labor induction.

    Directory of Open Access Journals (Sweden)

    Mandana Mansour Ghanaie

    2013-06-01

    Full Text Available The aim of this study is to further compare the efficacy of PGE2 suppository, the intracervical foley catheter and extra-amniotic saline infusion in nulliparous women referred for labor induction.Totally 368 nulliparous women with a Bishop score ≤ 4 with singleton gestation, vertex presentation and intact membrane referred for labor induction were randomly assigned to 3 groups; Foley catheter alone, Extra-amniotic saline infusion (EASI and PGE2 suppository. All women received concurrent dilute oxytocine infusion. The change in the Bishop Score, labor progress, various labor endpoints and outcomes of labor were assessed.From 363 women studied after exclusion of 5, 119 were assigned to EASI, 121 to Foley and 118 to PGE2. Patients' demographics did not differ significantly between three groups nor did indication for induction (P = 0.0001. The EASI group had a significant improvement in Bishop Score 6 hours after induction. The mean time to active phase was 357±135min for EASI,457±178 for Foley and 609±238 min for PGE2 group respectively (P < 0.05.rate of spontaneous rupture of membranes was higher in the EASI group (P = 0.0001 and the mean time from the start of induction up to spontaneous rupture of membranes in the EASI group was shorter than other group(P < 0.05. The mean time to vaginal delivery was 14.8±6.1 in EASI group,11.4±4.8 in Foley and 18.9±6.4 in PGE2 group(P < 0.05.there were no differences in Apgar scores, mean neonatal birth weight and neonatal morbidity.Our study showed that pre-induction cervical ripening by EASI with concurrent oxytocin is better than Foley and PGE2 in Bishop score and various labor end point and outcomes.

  13. Insulin compatibility with polymer materials used in external pump infusion systems.

    Science.gov (United States)

    Melberg, S G; Havelund, S; Villumsen, J; Brange, J

    1988-04-01

    In a study designed to mimic actual user conditions for external insulin pump infusion, the insulin quality after passage through the infusion set was assessed by various analytical methods, including high performance liquid chromatography. The two infusion sets tested consisted of, firstly, a polyvinylchloride/rubber syringe and a polyvinylchloride catheter sterilized by gamma irradiation and, secondly, a polyethylene/polypropylene syringe connected to a polyethylene catheter and sterilized by ethylene oxide. The insulin solution delivered through the PVC infusion set showed a reduction of preservative to less than 30% of the initial content and increased formation of chemical transformation products of insulin varying from twice the reference level during the first day to more than three times on the third day. By contrast, the polyethylene/polypropylene infusion system showed only a minor decrease in preservative content and no increase in chemical transformation. These effects were observed irrespective of the brand of insulin and were not affected by increase of the zinc content of the insulin solution. Investigation of the influence of the sterilization methods performed on polyvinylchloride and polyethylene catheters revealed that gamma irradiated polyvinylchloride catheters were markedly harmful to the insulin solution, whereas ethylene oxide sterilization did not influence the chemical stability of insulin.

  14. Outcome of tunneled infusion catheters inserted via the right internal jugular vein

    International Nuclear Information System (INIS)

    Shin, Sung Wook; Do, Young Soo; Choo, Sung Wook; Yoo, Wi Kang; Choo, In Wook; Kim, Jae Hyung

    2003-01-01

    To assess the outcome of tunneled central venous catheter placement via the right internal jugular vein. Between June 2001 and May 2002, 670 consecutive Hickman catheters were placed in 654 patients via the right internal jugular vein. The procedural complications arising and follow-up data obtained from May to July 2002 were evaluated. The technical success rate for catheter placement was 99.9% (669/670). Procedural complications were limited to eight cases (1.2%), including three pneumothoraces, one early migration of the catheter, one clinically unimportant air embolism, one catheter injury, one catheter kinking and one primary malpositioning in the azygos vein. Catheter dwelling time ranged from 1 to 407 (mean 107.1) days. During the follow-up period, 416 catheter were removed for various reasons: treatment had ended (n=334), patients declined treatment or their drug regimen was changed (n=16), late complications arose (n=53), or other circumstances intervened (n=13). Late complications included 44 cases of catheter-related infection (6.6%), five of catheter migration (0.7%), two of catheter occlusion (0.3%), one of thrombophlebitis (0.15%), and one of catheter-related right atrial thrombosis (0.15%). Only one instance of symptomatic venous thrombosis or stenosis was noted, namely the one case of thrombophlebitis. Because the incidence of subsequent symptomatic venous thrombosis or stenosis is lower, the preferred route for tunneled central venous catheter placement is the right internal jugular vein

  15. Combined intra-arterial infusion and radiotherapy for the head and neck tumors, 1

    International Nuclear Information System (INIS)

    Hattori, Takao

    1989-01-01

    A superselective insertion of a long-term retaining infusion catheter via superficial temporal artery was attempted in 77 patients with head and neck cancer treated between February 1984 and April 1988. It was successfully accomplished in 73 patients (95%). In 67 patients receiving the combination of radiotherapy, average durations of the catheter inserted into the maxillary, lingual, and facial arteries were 27, 31, and 29 days, respectively. Continuous arterial infusion chemotherapy was attained through the catheter. Possible complications of catheter insertion were as follows: local infection (5), blood clots inside the catheter (4), change in the tip of the catheter (3), spontaneous removal of the catheter (3), catheter injury (2), bleeding in the inserted area (one), and intimal injury (one). No other severe complications were observed. The superselective insertion of the catheter seemed to be superior to conventional method in view of its safety and accuracy. (Namekawa, K)

  16. Total parenteral alimentation via indwelling umbilical catheters in the newborn period.

    Science.gov (United States)

    Hall, R T; Rhodes, P G

    1976-01-01

    Total parenteral alimentation (TPA) was delivered to 80 infants via indwelling umbilical artery and to 9 via indwelling umbilical venous catheters. The primary indication for catheter placement and maintenance was monitoring of arterial blood gases (umbilical venous catheter tip in left atrium) in a group of sick neonates requiring increased inspired oxygen or assisted ventilation. Results were compared with those from 23 infants who had tunnelled jugular catheters for a variety of chronic medical and surgical problems preventing gastric or intestinal feeding. A mean weight gain was achieved in both groups. Mortality and morbidity rates were similar in both groups. The most common complications were infection and thrombotic phenomena. Metabolic complications were few. It is concluded that infusing TPA solutions via indwelling umbilical catheters presents no greater risk than infusion via tunnelled jugular catheters, and provides a method for supplying adequate caloric intake for growth during the acute stage of illness. PMID:827978

  17. Adjuvant Hepatic Arterial Infusion Chemotherapy After Resection for Pancreatic Cancer Using Coaxial Catheter-Port System Compared with Conventional System

    International Nuclear Information System (INIS)

    Hashimoto, Aya; Tanaka, Toshihiro; Sho, Masayuki; Nishiofuku, Hideyuki; Masada, Tetsuya; Sato, Takeshi; Marugami, Nagaaki; Anai, Hiroshi; Sakaguchi, Hiroshi; Kanno, Masatoshi; Tamamoto, Tetsuro; Hasegawa, Masatoshi; Nakajima, Yoshiyuki; Kichikawa, Kimihiko

    2016-01-01

    PurposePrevious reports have shown the effectiveness of adjuvant hepatic arterial infusion chemotherapy (HAIC) in pancreatic cancer. However, percutaneous catheter placement is technically difficult after pancreatic surgery. The purpose of this study was to evaluate the feasibility and outcome of HAIC using a coaxial technique compared with conventional technique for postoperative pancreatic cancer.Materials and Methods93 consecutive patients who received percutaneous catheter-port system placement after pancreatectomy were enrolled. In 58 patients from March 2006 to August 2010 (Group A), a conventional technique with a 5-Fr indwelling catheter was used and in 35 patients from September 2010 to September 2012 (Group B), a coaxial technique with a 2.7-Fr coaxial catheter was used.ResultsThe overall technical success rates were 97.1 % in Group B and 86.2 % in Group A. In cases with arterial tortuousness and stenosis, the success rate was significantly higher in Group B (91.7 vs. 53.8 %; P = 0.046). Fluoroscopic and total procedure times were significantly shorter in Group B: 14.7 versus 26.7 min (P = 0.001) and 64.8 versus 80.7 min (P = 0.0051), respectively. No differences were seen in the complication rate. The 1 year liver metastasis rates were 9.9 % using the conventional system and 9.1 % using the coaxial system (P = 0.678). The overall median survival time was 44 months. There was no difference in the survival period between two systems (P = 0.312).ConclusionsThe coaxial technique is useful for catheter placement after pancreatectomy, achieving a high success rate and reducing fluoroscopic and procedure times, while maintaining the safety and efficacy for adjuvant HAIC in pancreatic cancer.

  18. Adjuvant Hepatic Arterial Infusion Chemotherapy After Resection for Pancreatic Cancer Using Coaxial Catheter-Port System Compared with Conventional System

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Aya; Tanaka, Toshihiro, E-mail: toshihir@bf6.so-net.ne.jp [Nara Medical University, Department of Radiology (Japan); Sho, Masayuki [Nara Medical University, Department of Surgery (Japan); Nishiofuku, Hideyuki; Masada, Tetsuya; Sato, Takeshi; Marugami, Nagaaki [Nara Medical University, Department of Radiology (Japan); Anai, Hiroshi [Nara City Hospital, Department of Radiology (Japan); Sakaguchi, Hiroshi [Nara Prefectural Western Medical Center, Department of Radiology (Japan); Kanno, Masatoshi [Nara Medical University, Oncology Center (Japan); Tamamoto, Tetsuro; Hasegawa, Masatoshi [Nara Medical University, Department of Radiation Oncology (Japan); Nakajima, Yoshiyuki [Nara Medical University, Department of Surgery (Japan); Kichikawa, Kimihiko [Nara Medical University, Department of Radiology (Japan)

    2016-06-15

    PurposePrevious reports have shown the effectiveness of adjuvant hepatic arterial infusion chemotherapy (HAIC) in pancreatic cancer. However, percutaneous catheter placement is technically difficult after pancreatic surgery. The purpose of this study was to evaluate the feasibility and outcome of HAIC using a coaxial technique compared with conventional technique for postoperative pancreatic cancer.Materials and Methods93 consecutive patients who received percutaneous catheter-port system placement after pancreatectomy were enrolled. In 58 patients from March 2006 to August 2010 (Group A), a conventional technique with a 5-Fr indwelling catheter was used and in 35 patients from September 2010 to September 2012 (Group B), a coaxial technique with a 2.7-Fr coaxial catheter was used.ResultsThe overall technical success rates were 97.1 % in Group B and 86.2 % in Group A. In cases with arterial tortuousness and stenosis, the success rate was significantly higher in Group B (91.7 vs. 53.8 %; P = 0.046). Fluoroscopic and total procedure times were significantly shorter in Group B: 14.7 versus 26.7 min (P = 0.001) and 64.8 versus 80.7 min (P = 0.0051), respectively. No differences were seen in the complication rate. The 1 year liver metastasis rates were 9.9 % using the conventional system and 9.1 % using the coaxial system (P = 0.678). The overall median survival time was 44 months. There was no difference in the survival period between two systems (P = 0.312).ConclusionsThe coaxial technique is useful for catheter placement after pancreatectomy, achieving a high success rate and reducing fluoroscopic and procedure times, while maintaining the safety and efficacy for adjuvant HAIC in pancreatic cancer.

  19. Clinical Application of a New Indwelling Catheter with a Side-Hole and Spirally Arranged Shape-Memory Alloy for Hepatic Arterial Infusion Chemotherapy

    International Nuclear Information System (INIS)

    Yagihashi, Kunihiro; Takizawa, Kenji; Ogawa, Yukihisa; Okamoto, Kyoko; Yoshimatsu, Misako; Fujikawa, Atsuko; Shimamoto, Hiroshi; Nakajima, Yasuo

    2010-01-01

    A new indwelling catheter, G-spiral (GSP), was developed for hepatic arterial infusion chemotherapy (HAIC) by way of an implanted catheter-port system (CPS). Here we evaluated its physical properties and the outcomes of its clinical use. The GSP vessel-fixing power and its ability to follow a guidewire were determined with a vascular in vitro model, and Student t test was used to determine statistical significance (P < 0.05). A retrospective analysis was performed to evaluate the technical success rate and to identify the clinical complications associated with radiologic CPS implantation with GSP in 65 patients with unresectable hepatic tumors. The mean vessel-fixing power of the GSP (14.4 g) significantly differed from that of a GSP with a cut shape-memory alloy (3.3 g). The mean resistance to following the guidewire displayed by the GSP (88.5 g) was significantly less than that for a 5F W-spiral (106.3 g) or 4F Cobra-type angiographic catheter (117.8 g). The CPS was placed successfully in 64 of 65 cases (98.5%). Hepatic artery occlusion was observed in one case. Occlusion, cracking, and infection of CPS were observed in one, two, and one case, respectively. The GSP is a highly useful indwelling catheter that can be used for HAIC.

  20. Tracer studies with aortic infusion result in improper tracer distribution

    International Nuclear Information System (INIS)

    Wisneski, J.A.; Brooks, G.A.; Neese, R.A.; Stanley, W.C.; Morris, D.L.; Gertz, E.W.

    1986-01-01

    It has been suggested that lactate turnover can be accurately assessed by infusing radioactive lactate tracer into the aorta and sampling blood in the vena cava. However, there may be streaming of newly infused tracer in the aorta, resulting in a nonuniform arterial specific activity (SA). Furthermore vena caval blood may not be representative of mixed venous blood. The authors examined this problem in 7 anesthetized dogs with sampling catheters in the pulmonary (PA), carotid (CA), and femoral (FA) arteries, and the superior (SVC) and inferior (IVC) vena cavi. [1- 14 C]lactate was continuously infused into the left ventricle through a catheter introduced through the femoral artery. The same SA (dpm/μmol) was found in the CA and FA, indicating adequate mixing of newly infused tracer with trace. Three dogs showed differences between SVC, IVC and PA, suggesting a mixed venous sample can not be obtained from the VC. When the catheter was moved into the aorta, wide differences in SA appeared between the CA and FA, clearly reflecting streaming of tracer. These differences also appeared in the SVC and IVC. In conclusion, adequate mixing does not occur between tracer and trace in arterial blood with aortic infusion. Further, VC sampling will not give a consistent mixed venous SA. Therefore, for practical reasons, aortic tracer infusion with vena caval sampling will lead to erroneous turnover values

  1. Bupivacaine constant continuous surgical wound infusion versus continuous epidural infusion for post cesarean section pain, randomized placebo-controlled study

    Directory of Open Access Journals (Sweden)

    Hossam A. ELShamaa

    2016-10-01

    Conclusion: The current study demonstrated that bupivacaine administered by continuous epidural infusion provided a significantly lower pain scores with mobilization, and hence better analgesia for post cesarean section pain in the first postoperative day compared to continuous bupivacaine wound infusion through fenestrated catheter using the constant flow PainFusor system.

  2. Prospect of drug distribution to hepatic cancer in intra-arterial infusion chemotherapy. Examination by infusion of sup(81m)Kr and /sup 133/Xe via catheter into hepatic artery

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, Y; Imaoka, S; Matsui, Y; Ishikawa, O; Taniguchi, K [Osaka Prefectural Center for Adult Diseases (Japan)

    1982-04-01

    Cannulation into the hepatic artery under laparotomy was performed to nine patients of non-resectable hepatic cancer (eight of hepatocellular carcinoma, and one of cholangiocellular carcinoma), and injected sup(81m)Kr (Tsub(1/2) = 13 sec.) continuously via catheter into hepatic artery as the model of continuous intra-arterial infusion chemotherapy, and /sup 133/Xe (Tsub(1/2) = 5.3 days) by bolus injection as the model of one-shot ones. During and immediately after injection, sequential scintigrams were carried out and simultaneously images were acquired on a medical computer. Higher radioactivities of both sup(81m)Kr and /sup 133/Xe were observed in tumor than non-tumor region in seven of eight patients of hepatocellular carcinoma. The radioactive ratio of tumor to non-tumor (T/C ratio) was over 1.0 in these cases. This result indicated that there was more arterial blood flow in tumor than non-tumor region, and it could be expected to obtain higher distribution of drugs in tumor on both continuous and one-shot infusion chemotherapy. The pattern of distribution of sup(81m)Kr changed according to positions of patients, and in some cases T/C ratio was higher in other positions than supine position. The most effective position of the intra-arterial infusion chemotherapy could be selected by this method. This technique seems to make it possible to prospect the arrival of drugs to the tumor and presume the effectiveness of intra-arterial infusion chemotherapy.

  3. Induction of labour by balloon catheter with extra-amniotic saline infusion (BCEAS): a randomised comparison with PGE2 vaginal pessaries

    DEFF Research Database (Denmark)

    Lyndrup, J; Nickelsen, Carsten Nahne Amtof; Weber, Tom

    1994-01-01

    OBJECTIVE: A new method for induction of labour--balloon catheter with extra-amniotic saline infusion (BCEAS)--is evaluated in randomised comparison with prostaglandin E2 (PGE2) in vaginal pessaries. STUDY GROUP: One-hundred and nine pregnant women with unfavourable cervices. MAJOR OUTCOME MEASURES......: The efficiency of inducing vaginal delivery and the level of 'disadvantages following induction of labour' (DisFIL scorings). RESULTS: Overall, BCEAS was less efficient inducing vaginal delivery than vaginal PGE2 (P women (P ...) primiparous women group, and particularly in the subgroup of these having very low pelvic scores (Lange score,

  4. Value of Micronester coils in port-catheter implantation for continuous hepatic arterial infusion chemotherapy with fixed catheter tip method

    International Nuclear Information System (INIS)

    Yamagami, Takuji; Kato, Takeharu; Hirota, Tatsuya; Yoshimatsu, Rika; Matsumoto, Tomohiro; Nishimura, Tsunehiko; White, Robert I.

    2008-01-01

    To retrospectively evaluate the use of Micronester coils in port-catheter implantation with the fixed catheter tip method in comparison with other previously used coils. The cohort of this study was 143 consecutive patients with unresectable advanced liver cancer for whom a port-catheter system was percutaneously implanted. In the most recent 32 patients, Micronester coils were used for catheter tip fixation. Details of embolic agents for fixation, persistent blood flow beyond the distal end of the indwelling catheter, and complications were compared between cases without and with Micronester coils. In all, percutaneous port-catheter placement was successful. Mean number of coils used for fixation was 4.2 without Micronester coils vs. 2.5 with Micronester coils. N-butyl cyanoacrylate (NBCA)-Lipiodol was additionally used for catheter tip fixation in 85.6% of 111 procedures without Micronester coils and in 50% of 32 using Micronester coils. The gastroduodenal artery beyond the distal end was not detected at the final examination after any procedure. Catheter dislocation occurred in five and hepatic arterial obstruction or severe stenosis in eight. The number of coils used and necessity of NBCA-Lipiodol could be decreased with usage of Micronester coils without decreasing fixation ability compared to other coils. (orig.)

  5. Nursing care of indwelling catheter thrombolysis for acute thrombosis in the arteriovenous fistula in hemodialysis patients

    International Nuclear Information System (INIS)

    Gao Peizhu; Ding Wenbin; Ming Zhibing; Sun Juyun

    2010-01-01

    Objective: To summarize the experience of the nursing care of indwelling catheter thrombolysis for acute thrombosis in the arteriovenous fistula in eight hemodialysis patients. Methods: After breaking thrombus through indwelling catheter, both bolus injection and micro-pump continuous infusion of urokinase was employed in eight hemodialysis patients with acute thrombosis in the arteriovenous fistula. The necessary nursing measures were carried out to assist the whole therapeutic procedure. Results: All the patients could well cooperate with the procedure of indwelling catheter thrombolysis and urokinase infusion. The reopening rate of the obstructed fistula was 100%. Conclusion: Indwelling catheter thrombolysis with urokinase infusion is a simple, effective and safe treatment for acute thrombosis in the arteriovenous fistula in hemodialysis patients. In order to obtain optimal results, necessary nursing measures must be carried out. (authors)

  6. Krypton 81m infusion studies. Chapter 18

    International Nuclear Information System (INIS)

    Kaplan, E.; Mayron, L.W.; Friedman, A.M.; Gindler, J.E.

    1978-01-01

    A technique is described to give a continuous, constant-rate, intravascular infusion of 81 Krsup(m). Modifications of earlier generators included production of sodium-free 81 Rb, the use of a solution of commercial sterile isotonic non-ionic 5% dextrose-in-water as an eluant, the incorporation of a constant-rate infusion pump, and the miniaturization of the generator column and catheter system. Results are presented of studies of 81 Krsup(m) distribution in dogs, using both intravenous and intra-arterial infusion. (author)

  7. Local Intraarterial Thrombolysis: In Vitro Comparison Between Automatic and Manual Pulse-Spray Infusion

    International Nuclear Information System (INIS)

    Froelich, Jens J.; Freymann, Christina; Hoppe, Martin; Thiel, Thomas; Wagner, H. Joachim; Barth, Klemens H.; Klose, Klaus J.

    1996-01-01

    Purpose: Manual and automatic pulse-spray infusion techniques are compared in vitro to evaluate the efficacy of thrombolysis and the distribution of urokinase and saline solution within thrombus using a pulse-spray catheter. Methods: A pulse-spray catheter was introduced into a human thrombus within a stenotic flow model. Automatic and manual pulsed infusion of urokinase and automatic pulsed infusion of saline solution were compared. To quantify the efficacy of thrombolysis, pressure gradients were recorded proximal and distal to the thrombus and during the course of infusion. Distribution of infused urokinase was assessed radiographically. Results: The fastest and most homogeneous dissolution of the thrombus was achieved with automatic pulsed infusion of urokinase, shown by decreasing transthrombotic pressure gradients (p < 0.001, Wilcoxon, matched pairs). Manual pulsed infusion of urokinase or saline solution resulted in inhomogeneous thrombus dissolution and delayed thrombolysis. Conclusion: Application of automatic pulse-spray injectors seems beneficial for more effective and homogeneous intraarterial pulse-spray thrombolysis when compared with conventional manual pulsed technique

  8. Teflon pastille use in high dose dosimetry; Utilizacao de pastilhas de teflon em dosimetria de doses altas

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Maria Ines [Associacao Educacional Nove de Julho (UNINOVE), Sao Paulo, SP (Brazil); Caldas, Linda V.E., E-mail: miteixeira@ipen.b, E-mail: lcaldas@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-10-26

    This paper study the Teflon, which is used as aglomerant in the confection of dosimetric pastilles, for the viabilization of this material as high dose dosimeter. This paper used the OSL technique for the characterization of dosimetric properties of Teflon. The doses-response curve has been obtained for {sup 60}Co radiation between 100 Gy and 50 kGy, and the OSL answer reproducibility. The preliminary results shown that the Teflon is a material which can be used for high dose dosimetry

  9. Incidence of phlebitis associated with the use of peripheral IV catheter and following catheter removal.

    Science.gov (United States)

    Urbanetto, Janete de Souza; Peixoto, Cibelle Grassmann; May, Tássia Amanda

    2016-08-08

    to investigate the incidence of phlebitis and its association with risk factors when using peripheral IV catheters (PIC) and following their removal - (post-infusion phlebitis) in hospitalized adults. a cohort study of 171 patients using PIC, totaling 361 punctures. Sociodemographic variables and variables associated with the catheter were collected. Descriptive and analytical statistical analyses were performed. average patient age was 56.96 and 51.5% of the sample population was male. The incidence of phlebitis was 1.25% while using PIC, and 1.38% post-infusion. The incidence of phlebitis while using PIC was associated with the length of time the catheter remained in place, whereas post-infusion phlebitis was associated with puncture in the forearm. Ceftriaxone, Clarithromycin and Oxacillin are associated with post-infusion phlebitis. this study made it possible to investigate the association between risk factors and phlebitis during catheter use and following its removal. The frequency of post-infusion phlebitis was larger than the incidence of phlebitis with the catheter in place, with Phlebitis Grade III and II being the most frequently found in each of these situations, respectively. Aspects related to post-infusion phlebitis can be explained, given the limited number of studies addressing this theme from this perspective. investigar a incidência de flebites e a associação de fatores de risco com a sua ocorrência durante o uso e após a retirada do cateter intravenoso periférico - CIP (Flebite pós-infusão) em adultos hospitalizados. estudo de coorte com 171 pacientes com CIP, totalizando 361 punções. Foram coletadas variáveis sociodemográficas e relacionadas ao cateter. Análise estatística descritiva e analítica. dos pacientes, 51,5% eram homens e a média de idade foi de 56,96 anos. A incidência de flebites durante o uso do CIP foi de 1,25% e a pós-infusão foi de 1,38%. Associou-se à flebite durante o uso do CIP ao tempo de permanência do

  10. [Pain control by continuous infusion of morphine using subarachnoid catheter access to the port--a report of a home death case].

    Science.gov (United States)

    Kawagoe, Koh; Matsuura, Shinobu

    2008-12-01

    This is a case of a 50s male with cecal cancer suffering from severe pain caused by osteolytic metastasis to the lumbar vertebra, right iliac bone, and the head of the right femur. The pain was palliated by continuous infusion of morphine using a subarachnoid catheter that had access to the subcutaneous "Port". The maximum dose of morphine used a day was 384 mg, which corresponded to 57,600 mg/day of oral morphine. Sixty eight days after the start of home hospice care, the patient died at home because of diffuse peritonitis caused by intestinal rupture.

  11. [Incidence of phlebitis due to peripherally inserted venous catheters: impact of a catheter management protocol].

    Science.gov (United States)

    Ferrete-Morales, C; Vázquez-Pérez, M A; Sánchez-Berna, M; Gilabert-Cerro, I; Corzo-Delgado, J E; Pineda-Vergara, J A; Vergara-López, S; Gómez-Mateos, J

    2010-01-01

    To assess the impact on the incidence of PPIVC by implementing a catheter management protocol and to determine risk factors for PPIVC development in hospitalized patients. A total of 3978 episodes of venous catheterization were prospectively included from September 2002 to December 2007. A catheter management protocol was implemented during this period of time. The incidence and variables associated to the occurrence of PPIVC were determined. The incidence of PPIVC from 2002 to 2007 was 4.8%, 4.3%, 3.6%, 2.5%, 1.3% and 1.8% (phistory of phlebitis was the only factor independently associated to phlebitis due to peripherally inserted central venous catheters (AOR 3.24; CI at 95% CI= 1.05-9.98, p=0.04). A catheter management protocol decreases the incidence of PPIVC in hospitalized patients. The risk of PPIVC increases for peripherally inserted central venous catheters when the patients have a history of phlebitis and for peripheral venous catheters when amiodarone or cefotaxime are infused. Catheterization of peripheral veins performed during morning shifts is associated with a lower incidence of PPIVC when compared with night shift catheterizations.

  12. Hot Embossing for Whole Teflon Superhydrophobic Surfaces

    Directory of Open Access Journals (Sweden)

    Jie Li

    2018-06-01

    Full Text Available In this paper, we report a simple fabrication process of whole Teflon superhydrophobic surfaces, featuring high-aspect-ratio (>20 nanowire structures, using a hot embossing process. An anodic aluminum oxide (AAO membrane is used as the embossing mold for the fabrication of high-aspect-ratio nanowires directly on a Teflon substrate. First, high-aspect-ratio nanowire structures of Teflon are formed by pressing a fluorinated ethylene propylene (FEP sheet onto a heated AAO membrane at 340 °C, which is above the melting point of FEP. Experimental results show that the heating time and aspect ratios of nanopores in the AAO mold are critical to the fidelity of the hot embossed nanowire structures. It has also been found that during the de-molding step, a large adhesive force between the AAO mold and the molded FEP greatly prolongs the length of nanowires. Contact angle measurements indicate that Teflon nanowires make the surface superhydrophobic. The reliability and robustness of superhydrophobicity is verified by a long-term (~6.5 h underwater turbulent channel flow test. After the first step of hot-embossing the Teflon nanowires, microstructures are further superimposed by repeating the hot embossing process, but this time with microstructured silicon substrates as micromolds and at a temperature lower than the melting temperature of the FEP. The results indicate that the hot embossing process is also an effective way to fabricate hierarchical micro/nanostructures of whole Teflon, which can be useful for applications of Teflon material, such as superhydrophobic surfaces.

  13. Incidence of phlebitis and post-infusion phlebitis in hospitalised adults.

    Science.gov (United States)

    Urbanetto, Janete de Souza; Muniz, Franciele de Oliveira Minuto; Silva, Renata Martins da; Freitas, Ana Paula Christo de; Oliveira, Ana Paula Ribeiro de; Santos, Jessica de Cassia Ramos Dos

    2017-06-29

    to determine the incidence of phlebitis during and after the use of peripheral intravenous catheter (PIC), and analyse the association of this complication with risk factors. cohort study with 165 adult patients admitted to a university hospital in Porto Alegre, totalling 447 accesses, from December 2014 to February 2015. Data were collected on a daily basis and analysed by means of descriptive and analytical statistics. The incidence of phlebitis during PIC was 7.15% and the incidence of post-infusion phlebitis was 22.9%. Phlebitis during catheter use was associated with the use of Amoxicillin + Clavulanic Acid. The grade of post-infusion phlebitis was associated with age and use of Amoxicillin + Clavulanic Acid, Tramadol Hydrochloride, and Amphotericin. The incidence of post-infusion phlebitis proved to be an important indicator to analyse the quality of the healthcare setting.

  14. Study of teflon pads as high doses dosemeters

    International Nuclear Information System (INIS)

    Teixeira, Maria Ines; Caldas, Linda V.E.

    2013-01-01

    The aim of this work is to study the Teflon, which is used as a binder in the manufacture of dosimetric tablets, for the feasibility of this material as high dose dosemeter. In this paper we used the technique of thermally stimulated luminescence (OSL) to characterize the dosimetric properties of Teflon. Teflon samples were exposed to different doses of radiation, using a source of gamma radiation ( 60 Co). It was obtained dose-response curve between 100 Gy to 50 kGy and reproducibility of OSL response. The preliminary results show that Teflon is a useful material to high dose dosimetry

  15. Analysis of fallopian tube recanalization in 37 cases with Foley catheter infusion under pressure through DSA

    International Nuclear Information System (INIS)

    Huang Qiuli; Song Kankan; Wu Anle; Shu Jing

    2000-01-01

    Objective: To investigate the safe, effective, simple and direct method in the re-canalization of fallopian tubal obstruction. Methods: Fallopian tubal obstructive infertility in 37 cases were re-canalized with Foley catheter under pressure infusion through DSA, including primary infertility in 17 cases and secondary infertility in 20 cases. The average infertility term was 4 years. Results: In the 37 cases, 18 cases were treated once, twice in 16 cases, and thrice in 3 cases. The oviduct recanalization rate was 95% (35/37) with one failure and another unsatisfactory. After several times of recanalization in 19 cases, the pelvic cavity adhesion were reduced in 15 cases (79%), no change in 3 cases (16%), and aggravated in one case (5%). Conclusions: This method is simple, cheap, safety, effective and low in X-ray exposure. The authors insist on the pelvic cavity adhesion is still the chief cause of infertility after recanalization and still need other kind of treatment

  16. Intra-arterial and intraportal infusion liver scintigraphy using 99mTc-labeled colloid

    International Nuclear Information System (INIS)

    Inoue, Yusuke; Ohtake, Tohru; Momose, Toshimitsu; Watanabe, Toshiaki; Kosaka, Noboru; Nishikawa, Jun-ichi; Sasaki, Yasuhito; Sawada, Toshio; Muto, Tetsuichiro

    1991-01-01

    Intra-arterial infusion liver scintigraphy was performed in 11 patients with primary or metastatic liver tumor. and intraportal infusion liver scintigraphy was performed in 6 patients for prophylaxis of liver metastasis from colorectal cancer. 99m Tc-Sn colloid or 99m Tc-phytate was administered through the catheter of which tip was placed in the portal vein or the hepatic artery, and then liver image was obtained. When 99m Tc-phytate was infused intra-arterially, significant amount of the infused tracer passed through the liver and we could not get sufficient information to assess the distribution of drug administered through the catheter. On the other hand, intraportal infusion liver scintigraphy using 99m Tc-Sn colloid or 99m Tc-phytate and intra-arterial infusion liver scintigraphy using 99m Tc-Sn colloid revealed heterogenity of liver uptake, tracer uptake in spleen, low uptake area corresponding to the liver tumor and high uptake area around it. The findings will be clinically useful, and these methods are thought to be helpful to confirm the satisfactory drug distribution. (author)

  17. Biliary drainage by teflon endoprosthesis in obstructive jaundice - experiences in 69 patients treated by PTCD or ERCD

    Energy Technology Data Exchange (ETDEWEB)

    Rupp, N; Kramann, B; Gullotta, U; Reiser, M

    1983-02-01

    In 69 patients with extrahepatic biliary obstruction a specially designed teflon tube, the endoprosthesis, was inserted across the ductal stenosis either by percutaneous or by endoscopic route to reduce jaundice. After gaining experience our success rate of stent placement was more than 90%. Compared with catheter drainage the endoprosthesis worked faster and more efficiently, while in palliative treatment the quality of life of the patient improved and secondary cholangitis was prevented. The rate of significant long-term stent obstruction can be tolerated in view of the expected life span of four months as an average in our material.

  18. Intrathecal catheter-syringe adaptor for short-term intrathecal analgesia with an externalized pump: a case report.

    Science.gov (United States)

    Wilkes, Denise; Cook, Michael; Solanki, Daneshvari

    2010-01-01

    In most patients, cancer pain is effectively treated with conservative medical management consisting of oral and/or transdermal analgesics. Cancer patients tend to fail conservative medical management near the end of their life expectancy, thus requiring alternative routes of analgesia such as intravenous, epidural, or intrathecal. The intrathecal route provides the most effective analgesia due to the close proximity of the opioid receptors in the spinal cord. Though there are many techniques that exist for intrathecal drug delivery, complications can limit effectiveness such as infection, bleeding, cerebrospinal fluid (CSF) leaks, post-dural puncture headaches (PDPH), pump and/or catheter malfunctions, or limitations of technical expertise. Therefore, an important goal in palliative cancer pain therapy is to use equipment that is going to have the fewest number of complications and will be the most familiar to the health care providers. We describe the combination of the Medtronic Indura 1P catheter, which has the least catheter-related complications and can be used with any external drug infusion pump. These are regular infusion pumps that the health care workers are familiar with so they can provide excellent and efficient service to the patient. In an operating room, the intrathecal catheter was placed using sterile technique under fluoroscopic guidance. The epidural space was identified with loss of resistance technique. Then the introducer needle (supplied in the Indura 1P catheter kit) was advanced until free-flowing CSF was obtained. The spinal catheter was advanced into the intrathecal space through the introducer needle to lumbar 2-3 level. The catheter was tunneled subcutaneously 10 cm lateral to the catheter exit site. A syringe filling device was inserted into the catheter opening and was secured with silk suture. A luer lock syringe was attached to the syringe filling device and CSF was aspirated. The syringe filling device was capped and later

  19. Incidence of local complications and risk factors associated with peripheral intravenous catheter in neonates

    Directory of Open Access Journals (Sweden)

    Mitzy Tannia Reichembach Danski

    2016-02-01

    Full Text Available Abstract OBJECTIVE To evaluate the incidence of complications related to the use of peripheral intravenous catheter in neonates and identify the associated risk factors. METHOD Prospective cohort study conducted in a Neonatal Intensive Care Unit. Participants were the hospitalized neonates undergoing peripheral intravenous puncture in the period from February to June 2013. RESULTS The incidence of complications was 63.15%, being infiltration/extravasation (69.89%, phlebitis (17.84% and obstruction (12.27%. The risk factors were the presence of infection (p = 0.0192 and weight at the puncture day (p = 0.0093, type of intermittent infusion associated with continuous infusion (p <0.0001, endotracheal intubation (p = 0.0008, infusion of basic plan (p = 0.0027, total parenteral nutrition (P = 0.0002, blood transfusion associated with other infusions (p = 0.0003 and other drugs (p = 0.0004. Higher risk of developing complications in the first 48 hours after puncture. CONCLUSION A high rate of complications related to the use of peripheral intravenous catheter, and risk factors associated with infection, weight, drugs and infused solutions, and type of infusion.

  20. Mixing in the human carotid artery during carotid drug infusion studied with PET

    International Nuclear Information System (INIS)

    Junck, L.; Koeppe, R.A.; Greenberg, H.S.

    1989-01-01

    The safety and efficacy of drug infusion into the carotid artery require adequate mixing of the infused solution with carotid blood. Using positron emission tomography (PET), we studied the mixing of solutions infused into the human carotid artery in seven patients by analyzing the distribution of [15O]H2O infused into the carotid artery and by vein. At four infusion rates ranging from 0.5 to 10 ml/min, the variability in distribution averaged 16.5-17.8% among the pixels in a large volume of interest, without dependence on the infusion rate. The overall correlation between [15O]H2O influx with arterial infusion and [15O]H2O influx with venous injection was 0.78-0.82 at the four infusion rates, with no trend toward higher correlations at the faster infusion rates. The distribution into the anterior, middle, and posterior cerebral artery territories differed from distribution throughout the entire carotid territory by an average of 6.2-9.6% at the four infusion rates, with no trend toward smaller differences at the faster infusion rates. Infusions performed into a vinyl tube simulating the carotid artery indicated that at 0.5 ml/min, the velocity of fluid exiting the catheter makes no apparent contribution to mixing. We conclude that with infusions at the carotid bifurcation, mixing in the human carotid artery is complete or nearly complete over a wide range of infusion rates. The mixing appears to result from the patterns of blood flow within the artery, and not from jet effects at the catheter tip

  1. Predisposing factors to phlebitis in patients with peripheral intravenous catheters: a descriptive study.

    Science.gov (United States)

    Uslusoy, Esin; Mete, Samiye

    2008-04-01

    The purpose of this study was to investigate the predisposing factors in the development of phlebitis in peripheral intravenous (IV) catheterization sites in patients treated with a variety of IV infusion solutions and drugs. Systematic observation of 568 IV sites inserted for fluid infusion and drug administration in 355 patients in the Department of General Surgery of a University Hospital in Turkey. A data collection tool was based on standards established by the Infusion Nurses Society. Patients' infusion sites were monitored every 24 h during treatment and for 48 h after discontinuation of the IV. In contrast to the usual findings in the literature, the authors found that infusion through an infusion pump and insertion of catheters in the veins around the elbow increased the risk of phlebitis. Also, the number of times infusions were started led to an increased rate of phlebitis. However, conflicting results were obtained about the relation between phlebitis, gender, and catheter size. Phlebitis causes sepsis, pain, additional diagnostic investigations, and treatments, and may lead to increased duration of hospitalization, patient's stress level, and financial burden, as well as increasing staff workload. Advanced practice nurses need to be aware of the factors that increase the likelihood of phlebitis and take appropriate measures to prevent it.

  2. SU-C-9A-05: A Medical Physics Approach to the Evaluation of a New Anti-Reflux Catheter

    International Nuclear Information System (INIS)

    Pasciak, A; McElmurray, J

    2014-01-01

    Purpose: The Surefire Infusion System (SIS) is a coaxial microcatheter system with a pliant expanding tip designed to limit retrograde flow of administered intra-arterial embolic agents and resultant non-target embolization (NTE). A recent study suggests that the SIS may achieve relative arterial hypotension downstream to the catheter tip when compared to an end-hole catheter, potentially altering microsphere distribution. We have used a physics based approach to evaluate particulate distribution using both the SIS and standard end-hole microcatheter via a two-step same-day injection of Tc-99m MAA as a microsphere surrogate. Methods: Informed patient consent and IRB approval were obtained. Four patients with primary or secondary liver cancer underwent two sequential low-particulate infusions of Tc-99m MAA on the same day using both the SIS and a conventional end-hole catheter. Radiopharmaceutical dosages of approximately 1:8 were utilized in the first infusion relative to the second to eliminate the effect of residual activity on the images acquired after each step. SPECT imaging was obtained following each infusion, and MAA distribution was analyzed and compared. Archived fluoroscopic images confirmed near-identical catheter position for both infusions. Results: SPECT images from all four patients demonstrate qualitatively increased penetration of MAA distal to the site of infusion using the SIS when compared to a standard end-hole catheter. Quantitative evaluations corroborate these findings with some distal regions receiving between 33% to more than 200% greater relative activity when SIS was used. No appreciable NTE was identified in either patient subset. Conclusion: These preliminary data demonstrate the validity of this dual-infusion technique. Both qualitative and quantitative assessment of SPECT images and comparison with baseline contrast enhanced CT and PET/CT images indicate an improvement in MAA penetration into the target lesion with the SIS. However

  3. Induction of labour by balloon catheter with extra-amniotic saline infusion (BCEAS): a randomised comparison with PGE2 vaginal pessaries

    DEFF Research Database (Denmark)

    Lyndrup, J; Nickelsen, Carsten Nahne Amtoft; Weber, Tom

    1994-01-01

    section followed BCEAS than PGE2 (29% and 10%, respectively; P infectious complications were not recorded following BCEAS. No difference was apparent in the status of the neonates (judging from Apgar scores and umbilical artery pH and SBE). The women, delivering vaginally, commented......OBJECTIVE: A new method for induction of labour--balloon catheter with extra-amniotic saline infusion (BCEAS)--is evaluated in randomised comparison with prostaglandin E2 (PGE2) in vaginal pessaries. STUDY GROUP: One-hundred and nine pregnant women with unfavourable cervices. MAJOR OUTCOME MEASURES......: The efficiency of inducing vaginal delivery and the level of 'disadvantages following induction of labour' (DisFIL scorings). RESULTS: Overall, BCEAS was less efficient inducing vaginal delivery than vaginal PGE2 (P

  4. 21 CFR 870.1210 - Continuous flush catheter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Continuous flush catheter. 870.1210 Section 870.1210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... that permits continuous intravascular flushing at a slow infusion rate for the purpose of eliminating...

  5. Benchmarking the ERG valve tip and MRI Interventions Smart Flow neurocatheter convection-enhanced delivery system's performance in a gel model of the brain: employing infusion protocols proposed for gene therapy for Parkinson's disease

    Science.gov (United States)

    Sillay, Karl; Schomberg, Dominic; Hinchman, Angelica; Kumbier, Lauren; Ross, Chris; Kubota, Ken; Brodsky, Ethan; Miranpuri, Gurwattan

    2012-04-01

    Convection-enhanced delivery (CED) is an advanced infusion technique used to deliver therapeutic agents into the brain. CED has shown promise in recent clinical trials. Independent verification of published parameters is warranted with benchmark testing of published parameters in applicable models such as gel phantoms, ex vivo tissue and in vivo non-human animal models to effectively inform planned and future clinical therapies. In the current study, specific performance characteristics of two CED infusion catheter systems, such as backflow, infusion cloud morphology, volume of distribution (mm3) versus the infused volume (mm3) (Vd/Vi) ratios, rate of infusion (µl min-1) and pressure (mmHg), were examined to ensure published performance standards for the ERG valve-tip (VT) catheter. We tested the hypothesis that the ERG VT catheter with an infusion protocol of a steady 1 µl min-1 functionality is comparable to the newly FDA approved MRI Interventions Smart Flow (SF) catheter with the UCSF infusion protocol in an agarose gel model. In the gel phantom models, no significant difference was found in performance parameters between the VT and SF catheter. We report, for the first time, such benchmark characteristics in CED between these two otherwise similar single-end port VT with stylet and end-port non-stylet infusion systems. Results of the current study in agarose gel models suggest that the performance of the VT catheter is comparable to the SF catheter and warrants further investigation as a tool in the armamentarium of CED techniques for eventual clinical use and application.

  6. An experimental comparative study of radiography, ultrasonography and CT imaging in the IV catheter fragment

    International Nuclear Information System (INIS)

    Kweon, Dae Cheol

    2016-01-01

    The objective of this study was to detect the fragments generated during IV (intravenous) catheter injection of contrast medium and drug administration in a clinical setting and removal was performed by experimentally producing a phantom, and to compare the radiography, ultrasonography, and multi-detector computed tomography (MDCT) imaging and radiation dose. A 1 cm fragment of an 18 gage Teflon® IV catheter with saline was inserted into the IV control line. Radiography, CT, and ultrasonography were performed and radiography and CT dose were calculated. CT and ultrasonography showed an IV catheter fragment clinically and radiography showed no visible difference in the ability to provide a useful image of an IV catheter fragment modality (p >.05). Radiography of effective dose (0.2139 mSv·Gy-1·cm-2) form DAP DAP (0.93 μGy·m2 ), and dose length product (DLP) (201 mGy·cm) to effective dose was calculated as 0.483 mSv. IV catheter fragment were detected of radiography, ultrasonography and CT. These results can be obtained by menas of an excellent IV catheter fragment of detection capability CT. However, CT is followed by radiation exposure. IV catheter fragment confirming the position and information recommend an ultrasonography

  7. Clinical experience with the Monorail balloon catheter for coronary angioplasty.

    Science.gov (United States)

    Finci, L; Meier, B; Roy, P; Steffenino, G; Rutishauser, W

    1988-01-01

    The Monorail balloon catheter is distinctly different from other current balloon catheters: the guidewire passes through the balloon itself, exits the catheter proximal to the balloon, and runs alongside its small shaft (3 French) through the guiding catheter. Monorail coronary angioplasty was attempted in 61 patients on 73 lesions with balloons from 2.0 to 3.7 mm. Angiographic success was obtained in 66 lesions (90%). For 15 lesions, balloon exchanges were needed. In three lesions, the Monorail balloon failed to cross the lesion, while a standard balloon succeeded; two lesions could not be crossed with any balloon. Vessel occlusion occurred in four patients: two had emergency surgery without infarct (one died suddenly 4 days later and one had a stroke 1 day later), one was recanalized with a standard balloon, and one had a myocardial infarct. Continuous infusion of urokinase was used until patient 3 in whom problems with the delivery system led to cardiocerebral air embolization (with complete recovery). No thrombotic complications were observed in the subsequent 58 patients with only a bolus of 10,000 U of heparin. The Monorail balloon facilitates contrast injections and balloon exchanges but appears more difficult to pass through tight lesions. Omission of the previously recommended infusion with a thrombolytic agent proved safe.

  8. ADHESION AND SPREADING OF HUMAN FIBROBLASTS ON SUPERHYDROPHOBIC FEP-TEFLON

    NARCIS (Netherlands)

    BUSSCHER, HJ; STOKROOS, [No Value; GOLVERDINGEN, JG; SCHAKENRAAD, JM

    1991-01-01

    Adhesion and spreading of human fibroblasts was studied on hydrophobized and hydrophilized FEP-Teflon, and compared with adhesion and spreading on untreated FEP-Teflon and Tissue culture polystyrene (TCPS). Superhydrophobic FEP-Teflon was prepared by ion etching followed by oxygen glow-discharge.

  9. Delivery interaction between co-infused medications: an in vitro modeling study of microinfusion.

    Science.gov (United States)

    Tsao, Amy C; Lovich, Mark A; Parker, Michael J; Zheng, Hui; Peterfreund, Robert A

    2013-01-01

    To test the hypothesis that steady-state drug delivery by continuous infusion is predictably affected by a second drug infusion in the same lumen. Clinicians commonly administer two drugs by continuous infusion through one central venous catheter lumen (co-infusion). To limit fluid delivery, low flow rate carriers transport concentrated drug solutions; a method called microinfusion. How microinfusion delivery of one drug is affected by a second drug infusion has not been explored. Two water-soluble dyes, tartrazine and erioglaucine, infused at 3 ml · h(-1), modeled drug delivery through a four stopcock linear manifold and catheter lumen. A pump drove a carrier fluid (10 ml · h(-1)). After tartrazine reached steady-state delivery, erioglaucine entered downstream or upstream of the tartrazine infusion. Quantitative spectrophotometry measured dye delivery. Starting erioglaucine's infusion upstream of tartrazine's entry caused a transient tartrazine bolus (duration 10 min, peak drug delivery 20% higher than target levels). Starting erioglaucine's infusion downstream produced a similar amplitude, briefer, bolus. Stopping the erioglaucine infusion caused a transient reduction in tartrazine delivery. Measured delivery profiles were comparable to prediction models. We confirmed the hypothesis that delivery of one infused drug is transiently affected by starting or stopping a second drug infusion in the same line. The magnitude of the changes can be estimated quantitatively. The clinical impact depends on the drugs being co-infused and patient sensitivity, but could be clinically important; the findings have safety implications for infused medication delivery to critically ill or anesthetized children. We recommend minimizing infusion system dead volumes, connecting the most essential infusion(s) to the main fluid pathway as close as possible to the patient, and recognizing the potential for unintended alterations in delivery when multiple drugs co-infuse. © 2012

  10. Effect of abomasal glucose infusion on splanchnic and whole-body glucose metabolism in periparturient dairy cows

    DEFF Research Database (Denmark)

    Larsen, Mogens; Kristensen, Niels Bastian

    2009-01-01

    Six periparturient Holstein cows fitted with ruminal cannulas and permanent indwelling catheters in the hepatic portal vein, hepatic vein, mesenteric vein, and an artery were used to study the effects of abomasal glucose infusion on splanchnic and whole-body glucose metabolism.......Six periparturient Holstein cows fitted with ruminal cannulas and permanent indwelling catheters in the hepatic portal vein, hepatic vein, mesenteric vein, and an artery were used to study the effects of abomasal glucose infusion on splanchnic and whole-body glucose metabolism....

  11. High dose urokinase for restoration of patency of occluded permanent central venous catheters in hemodialysis patients.

    Science.gov (United States)

    Shavit, L; Lifschitz, M; Plaksin, J; Grenader, T; Slotki, I

    2010-10-01

    Catheter thrombosis is common and results in inadequate dialysis treatment and, frequently, in catheter loss. Since dialysis treatment runs on a strict schedule, occluded catheters need to be restored in a timely and cost effective manner. We present a new shortened protocol of urokinase infusion that allows hemodialysis to be performed within 90 minutes. To chronic hemodialysis patients, who developed complete catheter occlusion, urokinase was infused simultaneously through both lumens of the catheter (125,000 units to each lumen) over 90 minutes. Technical success was defined as restoring blood pump speed to at least 250 ml/min. We determined the average time from catheter placement to first clot event (primary patency PP), recurrent clot event after urokinase treatment (secondary patency SP), catheter salvage rate and cause for removal. 37 catheters developed total thrombosis and urokinase was used to restore patency one or more times (total 47 treatments). Catheter salvage rate was 97 %. The average time of PP was 152 ± 56 days (7 - 784 days). Nine patients (30%) developed recurrent occlusion and the average time of SP was 64 ± 34 days (2 - 364 days). One catheter was removed because of dysfunction due to thrombosis. Other catheters were removed due to infection, fistula maturation or fell out spontaneously. Hemodialysis was performed immediately after treatment with blood speed of 250 ml/min in all patients. Our protocol is highly effective, short, and allows to restore patency of totally occluded central venous catheters with minimal disruption of the dialysis session.

  12. Comparative study of peripherally inserted central venous catheter and traditional central catheter assisted with X-ray

    International Nuclear Information System (INIS)

    Yu Jianchun; Wang Xiurong; Jiang Zhuming

    1999-01-01

    Objective: To study the feasibility, complications, mid- and long-term advantages of peripherally inserted central catheters (PICC) compared with central venous access assisted with X-ray. Methods: From Jan 1997 to Dec 1998, the authors conducted a study in 60 patients with placed PICC lines and 60 patients with central lines. Study variables included tip placement and complication rates. Results: Tere were on significant differences between PICC and CVC in the successful placement 95.0% and 88.3%, t = 1.745, P 0.19; the mean duration 13(6-98) days and 14 (7-104) days, F = 0.049, P = 0.83; the total occlusion rate 6.7% (4/60) and 5.0%(3/60), t = 0.152, P = 0.70. In PICC patients, the occlusion rate was slightly higher in 3 Fr (20-gauge) catheter (3/20, 15.0%) than in 4 Fr(18-gauge) catheters (1/20, 5.0%), t = 1.111, P=0.29. Phlebitis occurred in 5.0% of patients (3/60) and one catheter fracture was happened on the catheter hub junction (1.7%). In 3 catheter tips dislocation cases, the catheter tips were moved to the optional position assisted with X-ray image. In CVC group, pneumothorax happened in 1 case (1.7%). In 4 catheter dislocation cases, the catheters were with drawn. No catheter-related sepsis and hemo-pneumothorax happened in both group patients. Conclusions: Both PICC and CVC can be acceptable in clinical use. PICC assisted with X-ray possesses the advantages of less trauma, accurate localization preventing some possible severe complications of central venous access such as pneumothorax. The new method provides a reliable, effective venous access for mid-and long-term usage in patients receiving a variety of solutions, primarily parenteral alimentation, chemotherapy or antibiotic infusion

  13. Radon daughter plate-out onto Teflon

    Science.gov (United States)

    Morrison, E. S.; Frels, T.; Miller, E. H.; Schnee, R. W.; Street, J.

    2018-01-01

    Radiopure materials for detector components in rare event searches may be contaminated after manufacturing with long-lived 210Pb produced by the decay of atmospheric radon. Charged radon daughters deposited on the surface or implanted in the bulk of detector materials have the potential to cause noticeable backgrounds within dark matter regions of interest. Understanding the mechanics governing these background signals is therefore a paramount concern in dark matter experiments in order to distinguish a real signal from internal detector backgrounds. Teflon (i.e. PTFE) is a specific material of interest because it makes up the walls of the inner detector of many liquid noble detectors such as the LUX-ZEPLIN experiment. The rate of radon daughter plate-out onto Teflon can be orders of magnitude larger than the plate-out rate onto other materials. Mitigation of plate-out onto Teflon and steel by proximity to other materials is demonstrated.

  14. Intracoronary infusion of catecholamines causes focal arrhythmias in pigs.

    Science.gov (United States)

    Doppalapudi, Harish; Jin, Qi; Dosdall, Derek J; Qin, Hao; Walcott, Gregory P; Killingsworth, Cheryl R; Smith, William M; Ideker, Raymond E; Huang, Jian

    2008-09-01

    Acute ischemia causes myriad changes including increased catecholamines. We tested the hypothesis that elevated catecholamines alone are arrhythmogenic. A 504 electrode sock was placed over both ventricles in six open-chest pigs. During control infusion of saline through a catheter in the left anterior descending coronary artery (LAD), no sustained arrhythmias occurred, and the refractory period estimated by the activation recovery interval (ARI) was 175 +/- 14 ms in the LAD bed below the catheter. After infusion of isoproterenol at 0.1 microg/kg/min through the catheter, the ARI in this bed was significantly reduced to 109 +/- 10 ms. A sharp gradient of refractoriness of 43 +/- 10 ms was at the border of the perfused bed. Sustained monomorphic ventricular tachycardia occurred after drug infusion in the perfused bed or near its boundary in all animals with a cycle length of 329 +/- 26 ms and a focal origin. The maximum slope of the ARI restitution curve at the focal origins of the tachyarrhythmias was always <1 (0.62 +/- 0.15). Similar results with a focal arrhythmia origin occurred in two additional pigs in which intramural mapping was performed with 36 plunge needle electrodes in the left ventricular perfused bed. Regional elevation of a catecholamine, which is one of the alterations produced by acute ischemia, can by itself cause tachyarrhythmias. These arrhythmias are closely associated with a shortened refractory period and a large gradient of the spatial distribution of refractoriness but not with a steep restitution curve.

  15. Medication and volume delivery by gravity-driven micro-drip intravenous infusion: potential variations during "wide-open" flow.

    Science.gov (United States)

    Pierce, Eric T; Kumar, Vikram; Zheng, Hui; Peterfreund, Robert A

    2013-03-01

    Gravity-driven micro-drip infusion sets allow control of medication dose delivery by adjusting drops per minute. When the roller clamp is fully open, flow in the drip chamber can be a continuous fluid column rather than discrete, countable, drops. We hypothesized that during this "wide-open" state, drug delivery becomes dependent on factors extrinsic to the micro-drip set and is therefore difficult to predict. We conducted laboratory experiments to characterize volume delivery under various clinically relevant conditions of wide-open flow in an in vitro laboratory model. A micro-drip infusion set, plugged into a bag of normal saline, was connected to a high-flow stopcock at the distal end. Vertically oriented IV catheters (gauges 14-22) were connected to the stopcock. The fluid meniscus height in the bag was fixed (60-120 cm) above the outflow point. The roller clamp on the infusion set was in fully open position for all experiments resulting in a continuous column of fluid in the drip chamber. Fluid volume delivered in 1 minute was measured 4 times with each condition. To model resistive effects of carrier flow, volumetric infusion pumps were used to deliver various flow rates of normal saline through a carrier IV set into which a micro-drip infusion was "piggybacked." We also compared delivery by micro-drip infusion sets from 3 manufacturers. The volume of fluid delivered by gravity-driven infusion under wide-open conditions (continuous fluid column in drip chamber) varied 2.9-fold (95% confidence interval, 2.84-2.96) depending on catheter size and fluid column height. Total model resistance of the micro-drip with stopcock and catheter varied with flow rate. Volume delivered by the piggybacked micro-drip decreased up to 29.7% ± 0.8% (mean ± SE) as the carrier flow increased from 0 to 1998 mL/min. Delivery characteristics of the micro-drip infusion sets from 3 different manufacturers were similar. Laboratory simulation of clinical situations with gravity

  16. Tsukamurella catheter-related bloodstream infection in a pediatric patient with pulmonary hypertension

    Directory of Open Access Journals (Sweden)

    Kristen A. Wendorf

    2010-03-01

    Full Text Available Catheter-related bloodstream infections (CR-BSI are important complications in patients with long-term indwelling central venous catheters. In this report, we present the case of a 14-year-old male with pulmonary hypertension treated with continuous treprostinil infusion, who presented with a CR-BSI caused by a Tsukamurella species. This case highlights the potential for this unusual organism to cause infection in immunocompetent patients.

  17. An Experimental Study on Steel and Teflon Squeeze Film Dampers

    Directory of Open Access Journals (Sweden)

    Asad A. Khalid

    2006-01-01

    Full Text Available In this paper, the vibration analysis on Teflon and steel squeeze film dampers has been carried out. At different frequency ranges, vibration amplitude and the resonance frequency are measured. The eccentricity ratio at resonance speed has been determined. Results show that the vibration amplitude of the steel damper is 10% less at resonance compared with the Teflon damper. On the other hand, saving weight of 36% has been achieved by using the Teflon damper.

  18. Cardiac tamponade in an infant during contrast infusion through central venous catheter for chest computed tomography; Tamponamento cardiaco durante infusao de contraste em acesso venoso central para realizacao de tomografia computadorizada do torax em lactente

    Energy Technology Data Exchange (ETDEWEB)

    Daud, Danilo Felix; Campos, Marcos Menezes Freitas de; Fleury Neto, Augusto de Padua [Hospital Geral de Palmas, TO (Brazil)

    2013-11-15

    Complications from central venous catheterization include infectious conditions, pneumothorax, hemothorax and venous thrombosis. Pericardial effusion with cardiac tamponade hardly occurs, and in infants is generally caused by umbilical catheterization. The authors describe the case of cardiac tamponade occurred in an infant during chest computed tomography with contrast infusion through a central venous catheter inserted into the right internal jugular vein. (author)

  19. Impact of Multislice CT Angiography on Planning of Radiological Catheter Placement for Hepatic Arterial Infusion Chemotherapy

    International Nuclear Information System (INIS)

    Sone, Miyuki; Kato, Kenichi; Hirose, Atsuo; Nakasato, Tatsuhiko; Tomabechi, Makiko; Ehara, Shigeru; Hanari, Takao

    2008-01-01

    The objective of this study was to assess prospectively the role of multislice CT angiography (MSCTA) on planning of radiological catheter placement for hepatic arterial infusion chemotherapy (HAIC). Forty-six patients with malignant liver tumors planned for HAIC were included. In each patient, both MSCTA and intra-arterial digital subtraction angiography (DSA) were performed, except one patient who did not undergo DSA. Comparison of MSCTA and DSA images was performed for the remaining 45 patients. Detectability of anatomical variants of the hepatic artery, course of the celiac trunk, visualization scores of arterial branches and interobserver agreement, presence of arterial stenosis, and technical outcome were evaluated. Anatomical variations of the hepatic artery were detected in 19 of 45 patients (42%) on both modalities. The course of the celiac trunk was different in 12 patients. The visualization scores of celiac arterial branches on MSCTA/DSA were 3.0 ± 0/2.9 ± 0.2 in the celiac trunk, 3.0 ± 0/2.9 ± 0.3 in the common hepatic artery, 2.9 ± 0.2/2.9 ± 0.3 in the proper hepatic artery, 2.9 ± 0.3/2.9 ± 0.4 in the right hepatic artery, 2.8 ± 0.4/2.9 ± 0.4 in the left hepatic artery, 2.9 ± 0.2/2.9 ± 0.3 in the gastroduodenal artery, 2.1 ± 0.8/2.2 ± 0.9 in the right gastric artery, and 2.7 ± 0.8/2.6 ± 0.8 in the left gastric artery. No statistically significant differences exist between the two modalities. Interobserver agreement for MSCTA was equivalent to that for DSA. Two patients showed stenosis of the celiac trunk on both modalities. Based on these imaging findings, technical success was accomplished in all patients. In conclusion, MSCTA is accurate in assessing arterial anatomy and abnormalities. MSCTA can provide adequate information for planning of radiological catheter placement for HAIC

  20. Tumor and liver drug uptake following hepatic artery and portal vein infusion

    International Nuclear Information System (INIS)

    Sigurdson, E.R.; Ridge, J.A.; Kemeny, N.; Daly, J.M.

    1987-01-01

    Anatomic dye injection studies of the blood supply of colorectal hepatic metastases suggest that tumors are supplied predominantly by the hepatic artery. Using 13 N amino acids with dynamic gamma camera imaging in patients with colorectal hepatic metastases, it has been shown that hepatic artery infusion results in a significantly greater nutrient delivery to tumor compared with portal vein infusion. However, direct measurements of drug levels in tumor following hepatic artery and portal vein infusion in humans have not previously been reported. Patients with metastatic colorectal cancer confined to the liver received fluorodeoxyuridine (FUdR) through the hepatic artery or through the portal vein. All patients had previously failed systemic chemotherapy. Five patients with hepatic artery catheters were matched (by age, serum lactic dehydrogenase levels, percent hepatic replacement, and tumor size) with five patients with portal vein catheters. At operation, 3 H-FUdR (1 microCi/kg) and /sup 99m/Tc-macroaggregated albumin (MAA) (6 mCi) were injected into the hepatic artery or portal vein. Liver and tumor biopsies were obtained two and five minutes later. 3 H and /sup 99m/Tc were measured per gram tissue by scintillation and gamma counting. The mean liver levels following hepatic artery infusion (23.9 +/- 11.4 nmol/g) and portal vein infusion (18.4 +/- 14.5 nmol/g) did not differ. However, the mean tumor FUdR level following hepatic artery infusion was 12.4 +/- 12.2 nmol/g, compared with a mean tumor FUdR level following portal vein infusion of 0.8 +/- 0.7 nmol/g (P less than .01). This low level of tumor drug uptake after portal vein infusion of FUdR predicts minimal tumor response to treatment via this route. Thus, regional chemotherapy for established colorectal hepatic metastases should be administered through the hepatic artery

  1. Use of wound soaker catheters for the administration of local anesthetic for post-operative analgesia: 56 cases.

    Science.gov (United States)

    Abelson, Amanda L; McCobb, Emily C; Shaw, Scott; Armitage-Chan, Elizabeth; Wetmore, Lois A; Karas, Alicia Z; Blaze, Cheryl

    2009-11-01

    To describe the administration of local anesthetic through wound soaker catheters for post-operative veterinary patients and to characterize complications. Retrospective study of hospital records. Records of patients in which a wound soaker catheter was placed post-operatively between November 1, 2004 and July 1, 2006 at a veterinary teaching hospital. Records in which a limb amputation was performed between January 1, 2002 and August 1, 2007 and in which a wound soaker catheter was not placed were reviewed for historic control. A total of 56 cases were identified in which a wound soaker catheter was placed post-operatively including 52 dogs, 2 cats, and 2 goats. Twenty canine cases were identified in which limb amputation was performed and no wound soaker catheter was placed. The majority of surgical procedures for which a wound soaker catheter was placed included thoracic limb amputation (46.4%) and pelvic limb amputation (35.7%). Wound soaker catheters remained in place for an average of 1.6 +/- 0.5 days. Feline and caprine patients received intermittent bupivacaine boluses every 6 hours. Canine patients received continuous lidocaine infusions. Complications included disconnection of the catheter from the infusion (7.7%), one seroma, and one suspected lidocaine neurotoxicity. Incisional infections were noted in 3/56 (5.3%) limb amputations with wound soaker catheters placed which was not higher than the incisional infection rate found in the historic control cases 3/20 (15%). Use of the wound soaker catheter was a viable means of providing local analgesia in post-operative veterinary patients. Studies are needed to evaluate efficacy of pain management, and to further investigate techniques for catheter placement and maintenance which may help to optimize the analgesia achieved using this technique.

  2. Hepatic artery infusion (HAI) for hepatic metastases in combination with hepatic resection and hepatic radiation

    International Nuclear Information System (INIS)

    Merrick, H.W.; Dobelbower, R.R.; Ringleint, J.F.; Skeel, R.T.

    1986-01-01

    Renewed interest in hepatic artery infusion has been stimulated by the development of a totally implantable pump which eliminates many of the problems encountered by the external pumps and catheters. As the potential benefit of hepatic artery infusion would be greater if either all gross disease were removed by prior resection, or alternatively, if non-resectable disease were irradiated in conjunction with hepatic artery infusion, the authors initiated a phase I-II trial to evaluate combined modality therapy

  3. Selective cephalic upregulation of p-ERK, CamKII and p-CREB in response to glyceryl trinitrate infusion

    DEFF Research Database (Denmark)

    Ramachandran, Roshni; Pedersen, Sara Hougaard; Amrutkar, Dipak Vasantrao

    2018-01-01

    in the trigeminal and spinothalamic system after infusion of the migraine-provoking substance glyceryltrinitrate. Method A catheter was placed in the femoral vein of rats and one week later glyceryltrinitrate 4 µg/kg/min was infused for 20 min. Protein expression in the dura mater, trigeminal ganglion, nucleus...... glycerytrinitrate infusion ( P ... after glycerytrinitrate infusion with long-lasting expression of phosphorylated extracellular signal-regulated kinases observed in the nucleus caudalis. These activations were not observed at the spinal level....

  4. Successful treatment of massive pulmonary embolism with prolonged catheter-directed thrombolysis.

    LENUS (Irish Health Repository)

    Kelly, Peter

    2012-02-03

    This is a case report of a young woman who presented with an extensive pulmonary embolism and echocardiographic evidence of right ventricular dysfunction. Although hemodynamically stable, the patient\\'s clinical condition failed to improve with standard heparin anticoagulation. Successful local catheter-directed thrombolysis was performed over an extended period of 48 h with regular monitoring of response to therapy by computed tomography-pulmonary angiography and echocardiography. To our knowledge, treatment of a pulmonary embolism by catheter-directed thrombolytic infusion over an extended period of 48 h has not previously been described.

  5. Phlebitis associated with peripheral intravenous catheters in adults admitted to hospital in the Western Brazilian Amazon

    Directory of Open Access Journals (Sweden)

    Sandra Maria Sampaio Enes

    2016-04-01

    Full Text Available Abstract OBJECTIVE To identify the presence of phlebitis and the factors that influence the development of this complication in adult patients admitted to hospital in the western Brazilian Amazon. METHOD Exploratory study with a sample of 122 peripheral intravenous catheters inserted in 122 patients in a medical unit. Variables related to the patient and intravenous therapy were analyzed. For the analysis, we used chi-square tests of Pearson and Fisher exact test, with 5% significance level. RESULTS Complication was the main reason for catheter removal (67.2%, phlebitis was the most frequent complication (31.1%. The mean duration of intravenous therapy use was 8.81 days in continuous and intermittent infusion (61.5%, in 20G catheter (39.3%, inserted in the dorsal hand vein arc (36.9 %, with mean time of usage of 68.4 hours. The type of infusion (p=0.044 and the presence of chronic disease (p=0.005 and infection (p=0.007 affected the development of phlebitis. CONCLUSION There was a high frequency of phlebitis in the sample, being influenced by concomitant use of continuous and intermittent infusion of drugs and solutions, and more frequent in patients with chronic diseases and infection.

  6. Hepatic metabolism of anaesthetized growing pigs during acute portal infusion of volatile fatty acids and hydroxy-methyl butyrate

    DEFF Research Database (Denmark)

    Theil, Peter Kappel; Larsen, Uffe Krogh; Bjerre-Harpøth, Vibeke

    2016-01-01

    ABSTRACT: The objective of the experiment was to study hepatic metabolism during infusion of volatile fatty acids (VFA) differing in amounts and composition or infusion of HMB. Three fasted (20 h) pigs (mean BW ± SE; 58 kg ± 1) were fitted with indwelling catheters in the portal vein, hepatic vein......, respectively, for Inf2 and Inf3, or 65%, 20%, and 10% of acetate, propionate, and butyrate, respectively, for Inf4 and Inf5. In addition, for Inf5, HMB was infused at 2 mmol/h. Statistical analysis included fixed effects of infusion and interaction between infusion and samplings within infusion while...

  7. Thermoluminescent characteristics of diopside-teflon composites for radiation dosimetry

    International Nuclear Information System (INIS)

    Melo, A.P.; Caldas, L.V.E.

    2006-01-01

    Diopside - Teflon composites were been studied in relation to their dosimetric properties for high-dose dosimetry. Diopside from Minas Gerais, Brazil, CaMg(Si 2 O 6 ), was obtained in form of rude mineral with inclusions of quartz. The samples were prepared and only Diopside grains obtained. Pellets of Diopside-Teflon composites were prepared in the proportion of 2(Teflon): 1 (Diopside).The TL response repeatability presented a maximum coefficient of variation of 7.5%. The calibration curve is linear between 0.5 Gy and 1 kGy. TL emission spectra present three emissions of similar intensities at 570 nm, 590 nm and between 610-635 nm. The results suggest that the material presents good characteristics for use as high-dose radiation detectors. (Author)

  8. Deep venous thrombosis in the lower extremity: catheter-directed thrombolysis

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Byung Suk; Kim, En A; Park, Ki Han; Yoon, Kwon Ha; So, Byung Jun; Juhng, Seon Kwan; Won, Jin Jong [School of Medicine, Wonkwang University, Iksan (Korea, Republic of)

    2000-09-01

    To evaluate the efficacy of catheter-directed thrombolysis in treating symptomatic deep venous thrombosis (DVT) in lower limbs. Twenty-six consecutive patients (16 male and 10 female; mean age, 55 years) with lower extremity DVT underwent thrombolytic therapy. The duration of symptoms was 1-90 (mean, 17) days: 20 days or less in 16 cases (acute DVT) and less than 20 days in ten (chronic DVT). Catheter-directed infusions of urokinase were administered via ipsilateral popliteal veins, and angioplasty or stent placement was performed after the thrombolytic procedure. Oral medication of warfarin continued for six months, and for the evaluation of venous patency, follow-up ultrasonography was performed. The total dose of infused urokinase was 1,750,000-10,000,000 (mean 4,84,000) IU, and the total procedural time was 25-115 (mean, 64) hours. Lysis was complete in 16 cases (62%, all acute DVT), partial in five (19%, chronic DVT), and failed in five (19%, chronic DVT). Eight patients with venous stenosis and two with occlusion were treated by means of angioplasty (n=3D4) or Wallstent placement (n=3D6). Minor bleeding occurred in six cases and major complications in two (one of pulmonary embolism, and one of multiorgan failure). Catheter-directed thrombolysis with urokinase is effective for the treatment of DVT in lower limbs. (author)

  9. Deep venous thrombosis in the lower extremity: catheter-directed thrombolysis

    International Nuclear Information System (INIS)

    Roh, Byung Suk; Kim, En A; Park, Ki Han; Yoon, Kwon Ha; So, Byung Jun; Juhng, Seon Kwan; Won, Jin Jong

    2000-01-01

    To evaluate the efficacy of catheter-directed thrombolysis in treating symptomatic deep venous thrombosis (DVT) in lower limbs. Twenty-six consecutive patients (16 male and 10 female; mean age, 55 years) with lower extremity DVT underwent thrombolytic therapy. The duration of symptoms was 1-90 (mean, 17) days: 20 days or less in 16 cases (acute DVT) and less than 20 days in ten (chronic DVT). Catheter-directed infusions of urokinase were administered via ipsilateral popliteal veins, and angioplasty or stent placement was performed after the thrombolytic procedure. Oral medication of warfarin continued for six months, and for the evaluation of venous patency, follow-up ultrasonography was performed. The total dose of infused urokinase was 1,750,000-10,000,000 (mean 4,84,000) IU, and the total procedural time was 25-115 (mean, 64) hours. Lysis was complete in 16 cases (62%, all acute DVT), partial in five (19%, chronic DVT), and failed in five (19%, chronic DVT). Eight patients with venous stenosis and two with occlusion were treated by means of angioplasty (n=3D4) or Wallstent placement (n=3D6). Minor bleeding occurred in six cases and major complications in two (one of pulmonary embolism, and one of multiorgan failure). Catheter-directed thrombolysis with urokinase is effective for the treatment of DVT in lower limbs. (author)

  10. Pulsatile versus steady infusions for hepatic artery chemotherapy

    International Nuclear Information System (INIS)

    Kim, E.E.; Haynie, T.P.; Wright, K.C.; Chaynsangavej, C.; Gianturco, C.; Lamki, L.; Wallace, S.

    1984-01-01

    Hepatic artery chemotherapy for unresectable liver tumors requires an even distribution of the drugs in the tumor or vascular bed. This cannot be determined angiographically because the drugs are infused at a much lower rate than the contrast media. It is easy, however, to determine the quality of the perfusion by injecting a small volume of Tc-99m MAA in one of the side ports while chemotherapeutic agent is being infused at the same rate. Usually this shows a uniform, satisfactory distribution of isotope. Occasionally, however, some areas fail to receive Tc-99m in spite of what appears to be a good position of the catheter tip. Since ''streaming'' of the infused drugs has been blamed for their uneven distribution, the authors decided to compare the usual steady flow infusions with infusions made pulsatile by the addition of a pulsing device (Gianturco Pump) attached to the infusion tubing. Eighty-three patients were studied with steady as well as pulsatile infusions. In 16 of these patients the perfusion pattern was definitely changed by the pulsatile infusion. In one patient the pulsatile mode resulted in an unwanted gastric perfusion. In 5 patients the distribution was improved in one hepatic lobe and in 10 patients it was improved in both lobes. These results show that hepatic artery perfusions can occasionally be improved by pulsing the infusate. However, pulsing can produce the unwanted perfusion of extra-hepatic areas

  11. Successful use of continuous vasodilator infusion to treat critical vasospasm threatening a distal bypass

    OpenAIRE

    Gregory A. Magee, MD, MSc; Anastasia Plotkin, MD; Jeniann A. Yi, MD, MS; Kathryn E. Bowser, MD; David P. Kuwayama, MD, MPA

    2018-01-01

    Vasospasm immediately after lower extremity arterial bypass may represent an uncommon cause of early graft failure. We report a successful case of catheter-directed, intra-arterial continuous vasodilator infusion to salvage a bypass graft threatened by severe, refractory vasospasm after incomplete response to nicardipine, verapamil, and nitroglycerin boluses. A continuous nitroglycerin infusion was administered for 24 hours, by which time the vasospasm resolved. At 12 months postoperatively, ...

  12. A new venous infusion pathway monitoring system.

    Science.gov (United States)

    Maki, Hiromichi; Yonezawa, Yoshiharu; Ogawa, Hidekuni; Ninomiya, Ishio; Sata, Koji; Hamada, Shingo; Caldwell, W Morton

    2007-01-01

    A new infusion catheter pathway monitoring system employing linear integrated circuits and a low-power 8-bit single chip microcomputer has been developed for hospital and home use. The sensor consists of coaxial three-layer conductive tapes wrapped around the polyvinyl chloride infusion tube. The inner tape is the main electrode, which records an AC (alternating current) voltage induced on the patient's body by electrostatic coupling from the normal 100 volt, 60 Hz AC power line wiring field in the patient's room. The outside tape layer is a reference electrode to monitor the AC voltage around the main electrode. The center tape layer is connected to system ground and functions as a shield. The microcomputer calculates the ratio of the induced AC voltages recorded by the main and reference electrodes and if the ratio indicates a detached infusion, alerts the nursing station, via the nurse call system or low transmitting power mobile phone.

  13. Next generation renal denervation: chemical “perivascular” renal denervation with alcohol using a novel drug infusion catheter

    Energy Technology Data Exchange (ETDEWEB)

    Fischell, Tim A. [Borgess Heart Institute, 1521 Gull Road, Kalamazoo, MI, 49008 (United States); Ablative Solutions, 801 Hermosa Way, Menlo Park, CA, 94025 (United States); Fischell, David R.; Ghazarossian, Vartan E. [Ablative Solutions, 801 Hermosa Way, Menlo Park, CA, 94025 (United States); Vega, Félix [Preclinical Consultation, San Francisco, CA (United States); Ebner, Adrian [Clinics, Ascension (Paraguay)

    2015-06-15

    Background/Purpose: We update the pre-clinical and early clinical results using a novel endovascular approach, to perform chemical renal denervation, via peri-adventitial injection of micro-doses of dehydrated alcohol (ethanol–EtOH). Methods/Materials: A novel, three-needle delivery device (Peregrine™) was used to denervate the renal arteries of adult swine (n = 17) and in a first-in-man feasibility study (n = 18). In the pre-clinical testing EtOH was infused bilaterally with one infusion per renal artery into to the perivascular space, using EtOH doses of 0.3 ml/artery (n = 8), and 0.6 ml/artery (n = 9), and with saline sham control (0.4 ml/artery n = 3). Renal parenchymal norepinephrine (NE) concentration (performed blindly), and safety were the primary endpoints. Data from the first-in-man study (n = 18) to evaluate device performance, safety and peri-procedural pain are reported. Results: In the pre-clinical testing renal function was unchanged at 3-month follow-up. Angiography at 90 days (n = 34 arteries) demonstrated normal appearing renal arteries, unchanged from baseline, and without stenosis or other abnormalities. The reductions in mean renal parenchymal NE reductions at 3 months were 68% and 88% at doses of 0.3 and 0.6 ml, respectively (p < 0.001 vs. controls). In the first-in-man study, there was 100% device success, no complications, a mean treatment time of 4.3 ± 3 minutes/artery, and minimal or no patient discomfort during treatment. Angiography at 6-months showed no evidence of renal artery stenosis, and evidence of a reduction of blood pressure from baseline. Conclusion: Perivascular RDN using micro-doses of alcohol is a promising alternative to energy-based systems to achieve dose-dependent, predictable, safe and essentially painless renal denervation. Further clinical evaluation is warranted. Summary: (For annotated table of contents) This paper describes the preclinical results, in a porcine model, and the early first-in-man results, using

  14. Incidence and severity of phlebitis in patients receiving peripherally infused amiodarone.

    Science.gov (United States)

    Boyce, Brenda A Brady; Yee, Barbara Homer

    2012-08-01

    Nurses noted that the rate of phlebitis was high when intravenous amiodarone was infused via a peripheral site. Hospital policy recommends a central vascular catheter, but this method is often not feasible because the drug is administered in emergent situations for short periods. To determine the rate and severity of phlebitis in patients given peripherally infused amiodarone. The literature, policy, and procedures for administration of amiodarone were reviewed; the pharmacy was consulted; and a data collection tool was developed. The tool was pilot tested and revised, and face validation was established. Data were collected during a 6-month period. A convenience sample was used. The study included a total of 12 patients. Each new infusion of intravenous amiodarone was considered a separate occurrence, for a total of 24 infusions. Various grades of phlebitis developed in 8 patients (67%). Phlebitis developed at 12 of the 24 infusion sites (50%). Patients receiving peripherally infused amiodarone are at high risk for phlebitis. This complication may lead to infection, additional medical intervention, delay in treatment, and prolonged hospitalization.

  15. Impact of quality management monitoring and intervention on central venous catheter dysfunction in the outpatient chemotherapy infusion setting.

    Science.gov (United States)

    Bansal, Anu; Binkert, Christoph A; Robinson, Malcolm K; Shulman, Lawrence N; Pellerin, Linda; Davison, Brian

    2008-08-01

    To assess the utility of maintaining and analyzing a quality-management database while investigating a subjectively perceived increase in the incidence of tunneled catheter and port dysfunction in a cohort of oncology outpatients. All 152 patients undergoing lytic therapy (2-4 mg alteplase) of a malfunctioning indwelling central venous catheter (CVC) from January through June 2004 at a single cancer center in the United States were included in a quality-management database. Patients were categorized by time to device failure and the initial method of catheter placement (surgery vs interventional radiology). Data were analyzed after 3 months, and areas of possible improvement were identified and acted upon. Three months of follow-up data were then collected and similarly analyzed. In a 6-month period, 152 patients treated for catheter malfunction received a total of 276 doses of lytic therapy. A 3-month interim analysis revealed a disproportionately high rate (34%) of early catheter malfunction (ECM; <30 days from placement). Postplacement radiographs demonstrated suboptimal catheter positioning in 67% of these patients, all of whom had surgical catheter placement. There was a 50% absolute decrease in the number of patients presenting with catheter malfunction in the period from April through June (P < .001). Evaluation of postplacement radiographs in these patients demonstrated a 50% decrease in the incidence of suboptimal positioning (P < .05). Suboptimal positioning was likely responsible for some, but not all, cases of ECM. Maintenance of a quality-management database is a relatively simple intervention that can have a clear and important impact on the quality and cost of patient care.

  16. Percutaneous implantation of intra-arterial port system for regional drug infusion: results and complications in 110 cases

    International Nuclear Information System (INIS)

    Won, Je Hwan; Lee, Jong Hyuk; Ko, Kyung Hee; Won, Jong Yoon; Park, Sung Il; Lee, Do Yun; Kang, Byung Chul

    2000-01-01

    To investigate the feasibility and complications of a percutaneously implantable port system for regional drug infusion. For intra-arterial drug infusion, a 5.8 or 5-F pediatric venous port system was implanted in 110 patients with hepatocellular carcinoma (n=79), liver metastasis (n=16), gallbladder cancer (n=4), stomach cancer (n=3), pancreatic cancer (n=3), Burger's diseases mellitus (n=2), or lymphoma (n=1). All intra-arterial port implantations were performed percutaneously in an angiographic ward through the common femoral artery (n=98), left subclavian artery (n=10), or left superficial femoral artery (n=2). Complications were evaluated during the follow-up period, which ranged from 21 to 530 (mean, 163) days. The technical success rate for percutaneous implantation of the system was 97.3% (107 of 110 patients). The tips of the port catheter were located in the common hepatic artery (n=34), proper hepatic artery (n=49), right hepatic artery quick resulthepatic artery (n=1), descending aorta at T9 level (n=10), left popliteal artery (n=2), right external iliac artery (n=1), left external iliac artery (n=1), or left deep femoral artery (n=1). Complications were encountered in 24 patients (22.4%), namely chamber site infection (n=7), catheter dislodgement (n=7), catheter occlusion (n=3), migration of coil (n=2), disconnection between chamber and catheter (n=1), kinking of catheter (n=1), arterial occlusion (n=1), necrosis of overlying skin (n=1), and leakage around port chamber (n=1). Outcomes of complications included removal of port systems or cessation of therapy in 12 cases (11.2%), correction of catheter location using a guide wire in five (4.7%), thrombolysis with urokinase in three (2.8%), and straightening using a snare in one (0.9%). In three patients, the port system was used without reintervention. Percutaneous implantation of an intra-arterial port system showed a high technical success rate and a low rate of serious complications. The method may be

  17. Tensile strength decreases and perfusion pressure of 3-holed polyamide epidural catheters increases in long-term epidural infusion.

    Science.gov (United States)

    Kim, Pascal; Meyer, Urs; Schüpfer, Guido; Rukwied, Roman; Konrad, Christoph; Gerber, Helmut

    2011-01-01

    Epidural analgesia is an established method for pain management. The failure rate is 8% to 12% due to technical difficulties (catheter dislocation and/or disconnection; partial or total catheter occlusion) and management. The mechanical properties of the catheters, like tensile strength and flow rate, may also be affected by the analgesic solution and/or the tissue environment. We investigated the tensile strength and perfusion pressure of new (n=20), perioperatively (n=30), and postoperatively (n=73) used epidural catheters (20-gauge, polyamide, closed tip, 3 side holes; Perifix [B. Braun]). To prevent dislocation, epidural catheters were taped (n=5) or fixed by suture (n=68) to the skin. After removal, mechanical properties were assessed by a tensile-testing machine (INSTRON 4500), and perfusion pressure was measured at flow rates of 10, 20, and 40 mL/h. All catheters demonstrated a 2-step force transmission. Initially, a minimal increase of length could be observed at 15 N followed by an elongation of several cm at additional forces (7 N). Breakage occurred in the control group at 23.5±1.5 N compared with 22.4±1.6 N in perioperative and 22.4±1.7 N in postoperative catheters (Ptensile strength, whereas perfusion pressure at clinically used flow rates (10 mL/h) increased significantly from 19±1.3 to 44±72 mm Hg during long-term (≥7 days) epidural analgesia (Ptensile strength or perfusion pressure. Epidural catheter use significantly increases the perfusion pressure and decreases the tensile strength. Copyright © 2011 by American Society of Regional Anesthesia and Pain Medicine

  18. Adductor Canal Block With Continuous Infusion Versus Intermittent Boluses and Morphine Consumption

    DEFF Research Database (Denmark)

    Jaeger, Pia; Baggesgaard, Jonas; Sørensen, Johan K

    2018-01-01

    a randomized, blinded, controlled study, including patients scheduled for total knee arthroplasty with spinal anesthesia. Patients received 0.2% ropivacaine via a catheter in the adductor canal administered as either repeated intermittent boluses (21 mL/3 h) or continuous infusion (7 mL/h). The primary outcome...

  19. Extravasation of parenteral alimentation fluid into the renal pelvis--a complication of central venous catheter in a neonate.

    Science.gov (United States)

    Nadroo, A M; al-Sowailem, A M

    2001-01-01

    Many complications of central venous catheters, which include perforation of the vessel walls and extravasation of the infusate into pericardial, pleural, and peritoneal cavities, have been reported. We report an infant with a central venous catheter in inferior vena cava who experienced extravasation of parenteral alimentation fluid into the right renal pelvis secondary to perforation of the renal vein. To our knowledge, this rare complication has not been reported earlier.

  20. Is Thrombus With Subcutaneous Edema Detected by Ultrasonography Related to Short Peripheral Catheter Failure? A Prospective Observational Study.

    Science.gov (United States)

    Takahashi, Toshiaki; Murayama, Ryoko; Oe, Makoto; Nakagami, Gojiro; Tanabe, Hidenori; Yabunaka, Koichi; Arai, Rika; Komiyama, Chieko; Uchida, Miho; Sanada, Hiromi

    Short peripheral catheter (SPC) failure is an important clinical problem. The purpose of this study was to clarify the relationship between SPC failure and etiologies such as thrombus, subcutaneous edema, and catheter dislodgment using ultrasonography and to explore the risk factors associated with the etiologies. Two hundred catheters that were in use for infusion, excluding chemotherapy, were observed. Risk factors were examined by logistic regression analysis. Sixty catheters were removed as the result of SPC failure. Frequency of thrombus with subcutaneous edema in SPC failure cases was significantly greater than in those cases where therapy was completed without complications (P edema. Results suggest that subsurface skin assessment for catheterization could prevent SPC failure.

  1. Thermoluminescent dosemeters of CaSO4: Dy + Teflon

    International Nuclear Information System (INIS)

    Campos, L.L.

    1989-01-01

    The development of a pellet dosemeter of CaSO 4 : Dy + Teflon at the Dosimetric Materials Production Laboratory - IPEN/Brazilian CNEN-SP is presented. The pellets were produced by cold pressing and sintering a mixture of CaSO 4 : Dy and Teflon powders. The pellet characteristics from the point of view of dosimetry. A filter combination providing an energy independent response from 20 KeV to 1,25 MeV was obtained. The dosemeter consists of three pellets sealed between two thin plastic sheets and placed under plastic and lead filters. The combination of these three filters allows to determine the energy of an unknown source. (author) [pt

  2. Effects of volatile fatty acid supply on their absorption and on water kinetics in the rumen of sheep sustained by intragastric infusions

    NARCIS (Netherlands)

    Lopez, S.; Hovell, F.D.D.; Dijkstra, J.; France, J.

    2003-01-01

    Three sheep fitted with a ruminal cannula and an abomasal catheter were used to study water kinetics and absorption of VFA infused continuously into the rumen. The effects of changing VFA concentrations in the rumen by shifting VFA infusion rates were investigated in an experiment with a 3 x 3 Latin

  3. Simple and robust near-infrared spectroscopic monitoring of indium-tin-oxide (ITO) etching solution using Teflon tubing

    International Nuclear Information System (INIS)

    Nah, Sanghee; Ryu, Kyungtag; Cho, Soohwa; Chung, Hoeil; Namkung, Hankyu

    2006-01-01

    The ability to monitor etching solutions using a spectroscopy directly through existing Teflon lines in electronic industries is highly beneficial and offers many advantages. A monitoring method was developed using near-infrared (NIR) measurements with Teflon tubing as a sample container for the quantification of components in the indium-tin-oxide (ITO) etching solution composed of hydrochloric acid (HCl), acetic acid (CH 3 COOH) and water. Measurements were reproducible and it was possible to use the same calibration model for different Teflon tubings. Even though partial least squares (PLS) calibration performance was slightly degraded for Teflon cells when compared to quartz cells of the similar pathlength, the calibration data correlated well with reference data. The robustness of Teflon-based NIR measurement was evaluated by predicting the spectra of 10 independent samples that were collected using five different Teflon tubes. Although, two Teflon tubes were visually less transparent than the other three, there was no significant variation in the standard error of predictions (SEPs) among the five Teflon tubes. Calibration accuracy was successfully maintained and highly repeatable prediction results were achieved. This study verifies that a Teflon-based NIR measurement is reliable for the monitoring of etching solutions and it can be successfully integrated into on-line process monitoring

  4. [A new port catheter system of aluminum oxide ceramics].

    Science.gov (United States)

    Haindl, H; Schmoll, E; Willmann, G

    1995-03-01

    Implantable port catheter systems are becoming increasingly important, as they often permit out-patient treatment for many indications that would otherwise require hospitalization. Moreover, they also increase the safety/reliability of infusion therapy in critical inpatients. For a variety of reasons, the materials used so far, i.e. steel, titanium and various plastics have not been completely satisfactory. The main disadvantage of metallic systems is the formation of artefacts in tomographic images, while the shortcomings of plastics are mechanical, e.g. chip formation and early membrane failure. Against this background, a port catheter system made of alumina ceramic, which is largely free of the disadvantages of the other materials, was developed. The expected advantages in terms of complication rate and radiological artefacts, were fully confirmed by the evaluation of 160 monitored patients.

  5. A systematic review of extravasation and local tissue injury from administration of vasopressors through peripheral intravenous catheters and central venous catheters.

    Science.gov (United States)

    Loubani, Osama M; Green, Robert S

    2015-06-01

    The aim of this study was to collect and describe all published reports of local tissue injury or extravasation from vasopressor administration via either peripheral intravenous (IV) or central venous catheter. A systematic search of Medline, Embase, and Cochrane databases was performed from inception through January 2014 for reports of adults who received vasopressor intravenously via peripheral IV or central venous catheter for a therapeutic purpose. We included primary studies or case reports of vasopressor administration that resulted in local tissue injury or extravasation of vasopressor solution. Eighty-five articles with 270 patients met all inclusion criteria. A total of 325 separate local tissue injury and extravasation events were identified, with 318 events resulting from peripheral vasopressor administration and 7 events resulting from central administration. There were 204 local tissue injury events from peripheral administration of vasopressors, with an average duration of infusion of 55.9 hours (±68.1), median time of 24 hours, and range of 0.08 to 528 hours. In most of these events (174/204, 85.3%), the infusion site was located distal to the antecubital or popliteal fossae. Published data on tissue injury or extravasation from vasopressor administration via peripheral IVs are derived mainly from case reports. Further study is warranted to clarify the safety of vasopressor administration via peripheral IVs. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Pharmacokinetics and analgesic effect of ropivacaine during continuous epidural infusion for postoperative pain relief

    DEFF Research Database (Denmark)

    Erichsen, C J; Sjövall, J; Kehlet, H

    1996-01-01

    BACKGROUND: The pharmacokinetics and clinical efficacy of ropivacaine (2.5 mg/ml) during a 24-h continuous epidural infusion for postoperative pain relief in 20 patients scheduled for abdominal hysterectomy were characterized using an open-label, increasing-dose design. METHODS: Through an epidural...... catheter inserted at T10-T12, a test dose of 7.5 mg ropivacaine was given 3 min before a bolus dose of 42.5 mg and immediately followed by a 24-h continuous epidural infusion with either 10 or 20 mg/h. Peripheral venous plasma samples were collected up to 48 h after infusion, and urinary excretion...... plasma concentrations of ropivacaine increased markedly and consistently during the 24-h epidural infusion, in contrast to stable unbound concentrations. Both total and unbound plasma concentrations at the end of infusion were proportional to the total dose, although only the latter was proportional...

  7. Percutaneous hepatic arterial catheterization for infusion chemotherapy in treatment of primary hepatoma

    International Nuclear Information System (INIS)

    Juhn, Jae Ryang; Chang, Jae Yong; Cha, Seong Sook; Han, Sang Suk; Bae, Cheol; Kim, Sung Rok; Chae, Yoo Soon

    1984-01-01

    Chemotherapy offers palliative treatment to patient with advanced nonresectable hepatoma. The usefulness of systemic chemotherapy is limited because of serious side reaction and low concentration of drug at tumor. But this problem may be overcome by intraarterial infusion. Nonsurgical percutaneous hepatic arterial catheterization was done in 21 patients with primary hepatoma, and infusion chemotherapy was done in 19 patients who were successful in catheterization. The results were as follows: 1. Selective catheterization of hepatic artery proper, common hepatic artery, and celiac artery were successful in 4, 9 and 4 patients respectively. The success rate of selective catheterization is 80.9% including celiac artery among 21 patients with hepatoma. 2. Simple catheterization method was applied in 14 patients, and catheter exchange and Loop methods were applied in 2 and 1 patient respectively. 3. Complication related to catheterization, such as infection and bleeding on punctured site, intimal injury and dislodgement of catheter were not serious. 4. Drugs were well tolerated without serious toxicity or complication. 5. 3 patients showed objective response and median survival time of treated patients is 2.5 months.

  8. Micrococcus-associated central venous catheter infection in patients with pulmonary arterial hypertension.

    Science.gov (United States)

    Oudiz, Ronald J; Widlitz, Allison; Beckmann, X Joy; Camanga, Daisy; Alfie, Jose; Brundage, Bruce H; Barst, Robyn J

    2004-07-01

    To determine the incidence of catheter-related infection in patients with pulmonary arterial hypertension (PAH) receiving epoprostenol (EPO), and to note an etiologic role for Micrococcus spp, which is rarely reported as a pathogen in the medical literature. Observational study. Two PAH specialty treatment centers, Harbor-UCLA Medical Center (Torrance, CA), and the College of Physicians and Surgeons, Columbia University (New York, NY). A total of 192 patients with PAH receiving continuous therapy with IV EPO. From 1987 to 2000, 192 patients with PAH received infusions of EPO via central venous catheter. Catheter care included regular dressing changes with dry gauze using a sterile procedure, without the use of flushes. Patients were asked to report on known infections and treatments, and symptoms. All infections were verified by a telephone call to the patient, care provider, and microbiology laboratory whenever possible. There were 335,285 catheter days (mean +/- SD, 1,325 +/- 974 catheter days). There were 88 clinical catheter infections with 51 blood culture-positive infections, necessitating catheter removal in 38 instances. The following pathogens were isolated: Staphylococcus aureus (25); Micrococcus spp (14); mixed flora (3); coagulase-negative Staphylococcus spp (2); Corynebacterium spp (2); Serratia marcessens (1); Enterobacter spp (1); Pseudomonas aeruginosa (1); enterococci (1); and unidentified Gram-positive cocci (1). The catheter infection rate was 0.26 per 1,000 catheter days. The use of long-term therapy with continuous EPO appears to be associated with a low incidence of catheter-related infections. Micrococcus spp were the second most common etiologic agent. Caregivers managing patients with PAH must be aware of the risk of catheter infection, as it may contribute to the morbidity and mortality associated with the use of EPO. When isolated, Micrococcus spp should not be viewed as a contaminant, but rather as a true pathogen that may require

  9. Factors Associated with Continuous Low Dose Heparin Infusion for Central Venous Catheter Patency in Critically Ill Children Worldwide

    Science.gov (United States)

    Onyeama, Sara-Jane N; Hanson, Sheila J; Dasgupta, Mahua; Hoffmann, Raymond G; Faustino, Edward Vincent S

    2016-01-01

    Objective To identify patient, hospital and central venous catheter (CVC) factors that may influence the use of low dose heparin infusion (LDHI) for CVC patency in critically ill-children. Design Secondary analysis of an international multicenter observational study. Setting 59 Pediatric Intensive Care Units (PICUs) over four study dates in 2012, involving 7 countries. Patients Children less than 18 years of age with a CVC, admitted to a participating unit and enrolled in the completed PROTRACT study were included. All overflow patients were excluded. Interventions None. Measurements and Main Results Of the 2,484 patients in the PROTRACT study, 1,312 patients had a CVC. 507 of those patients used LDHI. The frequency of LDHI was compared across various patient, hospital and CVC factors using chi-squared, Mann-Whitney and Fisher's exact tests. In the multivariate analysis, age was not a significant factor for LDHI use. Patients with pulmonary hypertension had decreased LDHI use while those with active surgical or trauma diagnoses had increased LDHI use. All central CVC insertion sites were more likely to use LDHI when compared to peripherally inserted CVCs. The Asia-Pacific region showed increased LDHI use, along with community hospitals and smaller ICUs (LDHI in critically ill children. Further study is needed to evaluate the efficacy and persistence of LDHI use. PMID:27362853

  10. Enhancement of the CIGS solar cell's efficiency by anti-reflection coating with teflon AF

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Hong-Sub; Kim, Chan; Rhee, Il-Su [Kyungpook National University, Daegu (Korea, Republic of); Jo, Hyun-Jun; Kim, Dae-Hwan [Daegu Gyeongbuk Institute of Science and Technology, Daegu (Korea, Republic of); Hong, Sung-Wook [Daegu University, Gyeongsan (Korea, Republic of)

    2014-11-15

    An anti-reflection (AR) layer of Teflon AF was deposited on the front surface of a Cu(In,Ga)Se{sub 2} (CIGS) solar cell with a structure of grid/TCO/ZnO/CdS/Cu(In,Ga)Se{sub 2}/Mo/glass by using the spin coating method. This AR layer reduced the front-surface reflection, which resulted in high efficiency for the CIGS solar cell. The thickness of the Teflon AF layer was varied to determine the thickness that gave the highest transmittance of incident light into the active absorber of the CIGS solar cell. The optimum thickness of the Teflon AF layer was found to be 105 nm. CIGS solar cells with a Teflon AF layer of 105 nm were constructed, and their efficiencies were compared with those of solar cells without a Teflon AF layer. The average increase in the relative efficiency of the solar cells was 2.63% due to the inclusion of an anti-reflection layer of Teflon AF.

  11. Effect of abomasal glucose infusion on plasma concentrations of gut peptides in periparturient dairy cows

    DEFF Research Database (Denmark)

    Larsen, Mogens; Relling, A E; Reynolds, C K

    2010-01-01

    Six Holstein cows fitted with ruminal cannulas and permanent indwelling catheters in the portal vein, hepatic vein, mesenteric vein, and an artery were used to study the effects of abomasal glucose infusion on splanchnic plasma concentrations of gut peptides. The experimental design was a randomi...

  12. Effect of abomasal glucose infusion on splanchnic amino acid metabolism in periparturient dairy cows

    DEFF Research Database (Denmark)

    Larsen, Mogens; Kristensen, Niels Bastian

    2009-01-01

    Six Holstein cows fitted with ruminal cannulas and permanent indwelling catheters in the portal vein, hepatic vein, mesenteric vein, and an artery were used to study the effects of abomasal glucose infusion on splanchnic AA metabolism. The experimental design was a split plot, with cow as the whole...

  13. The development of a risk score for unplanned removal of peripherally inserted central catheter in newborns

    Directory of Open Access Journals (Sweden)

    Priscila Costa

    2015-06-01

    Full Text Available OBJECTIVE: to develop a risk score for unplanned removal of peripherally inserted central catheter in newborns.METHOD: prospective cohort study conducted in a neonatal intensive care unit with newborn babies who underwent 524 catheter insertions. The clinical characteristics of the newborn, catheter insertion and intravenous therapy were tested as risk factors for the unplanned removal of catheters using bivariate analysis. The risk score was developed using logistic regression. Accuracy was internally validated based on the area under the Receiver Operating Characteristic curve.RESULTS: the risk score was made up of the following risk factors: transient metabolic disorders; previous insertion of catheter; use of a polyurethane double-lumen catheter; infusion of multiple intravenous solutions through a single-lumen catheter; and tip in a noncentral position. Newborns were classified into three categories of risk of unplanned removal: low (0 to 3 points, moderate (4 to 8 points, and high (≥ 9 points. Accuracy was 0.76.CONCLUSION: the adoption of evidence-based preventative strategies based on the classification and risk factors faced by the newborn is recommended to minimize the occurrence of unplanned removals.

  14. Preoperative chemoradiotherapy using superselective intraarterial infusion via superficial temporal artery for stage III, IV oral cancer

    Energy Technology Data Exchange (ETDEWEB)

    Tohnai, Iwai; Shigetomi, Toshio [Nagoya Univ. (Japan). Graduate School of Medicine; Hayashi, Yasushi [Nagoya Second Red Cross Hospital (Japan)] (and others)

    2002-03-01

    Thirty-eight patients with stage III, IV oral cancer were treated by preoperative chemoradiotherapy using superselective intraarterial infusion via the superficial temporal artery. Radiotherapy (total dose: 40 Gy) and chemotherapy using CBDCA (total dose: 460 mg/m{sup 2}) were performed daily, followed by surgery. Catheter-insertion of 34 patients was done successfully. Four catheter insertions were not done successfully because of the anomaly of the artery such as common trunk of the lingual artery and the facial artery. The clinical effects were CR in 9 patients (26.5%) and PR in 25 (73.5%), and histopathological effects after surgery were grade III, IV in 10 (29.4%), grade IIb in 23 (67.6%), and grade IIa in 2 (5.8%). The 5-year cumulative survival rate was 67.8%. This superselective intra arterial infusion method could be the technique of choice for the treatment of oral cancer. (author)

  15. Preoperative chemoradiotherapy using superselective intraarterial infusion via superficial temporal artery for stage III, IV oral cancer

    International Nuclear Information System (INIS)

    Tohnai, Iwai; Shigetomi, Toshio

    2002-01-01

    Thirty-eight patients with stage III, IV oral cancer were treated by preoperative chemoradiotherapy using superselective intraarterial infusion via the superficial temporal artery. Radiotherapy (total dose: 40 Gy) and chemotherapy using CBDCA (total dose: 460 mg/m 2 ) were performed daily, followed by surgery. Catheter-insertion of 34 patients was done successfully. Four catheter insertions were not done successfully because of the anomaly of the artery such as common trunk of the lingual artery and the facial artery. The clinical effects were CR in 9 patients (26.5%) and PR in 25 (73.5%), and histopathological effects after surgery were grade III, IV in 10 (29.4%), grade IIb in 23 (67.6%), and grade IIa in 2 (5.8%). The 5-year cumulative survival rate was 67.8%. This superselective intra arterial infusion method could be the technique of choice for the treatment of oral cancer. (author)

  16. CaSO4: Dy + Teflon thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Campos, L.L.

    1986-01-01

    A pellet dosemeter of CaSO 4 : Dy + Teflon was developed at IPEN. CaSO 4 : Dy thermoluminescent phosphor, grown in the Dosimetric Materials Production Laboratory was chosen, due to its high sensitivity, ease of preparation and comparatively low cost. Pellets were produced by cold pressing and sintering a mixture of CaSO 4 : Dy and Teflon powders. Extensive work was done to study in detail all CaSO 4 : Dy pellets characteristics from the point of view of dosimetry with the purpose of introducing it in the routine use. A filter combination providing an energy independent response from 20 KeV to 1,25 MeV was obtained. The dosemeter consists of three pellets sealed between two thin plastic sheets and placed under plastic and lead filters. The combination of these tree filters allows the exposure as well as the energy determination of an unknown source. (Author) [pt

  17. Successful treatment of central venous catheter induced superior vena cava syndrome with ultrasound accelerated catheter-directed thrombolysis.

    Science.gov (United States)

    Dumantepe, Mert; Tarhan, Arif; Ozler, Azmi

    2013-06-01

    Superior vena cava (SVC) syndrome results from obstruction of flow through the vessel either by external compression or thrombosis. External compression by intrathoracic neoplasms is the most common etiology, especially lung cancer and lymphoma. Thrombosis is becoming increasingly common due to the use of indwelling catheters and implantable central venous access devices. Most patients are unresponsive to anticoagulation alone which appears to be effective only in the mildest cases. However, recent advances in catheter-based interventions have led to the development of a variety of minimally invasive endovascular strategies to remove venous thrombus and accepted as an important first-line treatment given its high overall success rate and low morbidity as compared with medical and surgical treatments. Ultrasound accelerated catheter-directed thrombolysis (UACDT) has been developed to rapidly and completely resolve the existing thrombus. This technique integrates high frequency, low intensity ultrasound (US) with standard CDT in order to accelerate clot dissolution, reducing treatment time and the incidence of thrombolysis-related complications. An US wave enhances drug permeation through thrombus by disaggregating the fibrin matrix, exposing additional plasminogen receptor sites to the thrombolytic agent. The US energy affects thrombus in the entire venous segment, increasing the probability of complete thrombus clearing. We report the case of a 56-year-old man who presented with a 5 days history of SVC syndrome symptoms who had been receiving chemotherapy for colon cancer through a right subclavian vein port catheter. The patient successfully treated with UACDT with EkoSonic(®) Mach4e Endovascular device with an overnight infusion. © 2013 Wiley Periodicals, Inc. Copyright © 2013 Wiley Periodicals, Inc.

  18. Delayed vocal fold paralysis after continuous interscalene level brachial plexus block with catheter placement: a case report.

    Science.gov (United States)

    Gollapalli, Lakshman; McKelvey, George; Wang, Hong

    2014-08-01

    We report an incident of delayed onset of true vocal fold paralysis with continuous interscalene brachial plexus block. A 51 year old woman underwent left shoulder manipulation and lysis of adhesions with fluoroscopy and general anesthesia. An interscalene brachial plexus block was performed and a catheter with a continuous infusion pump was placed for postoperative pain control. Following hospital discharge, approximately 8 hours after the initial catheter bolus the patient developed hoarseness, dysphagia, and dyspnea, secondary to left vocal fold palsy. The patient was admitted for observation and the catheter was discontinued with no intubation required. By the next morning, the patient's dysphagia and dyspnea had resolved and her hoarseness improved. Copyright © 2014. Published by Elsevier Inc.

  19. Intraarterial infusion chemotherapy for the treatment of metastatic liver cancer

    International Nuclear Information System (INIS)

    Arai, Yasuaki; Kido, Choichiro

    1987-01-01

    Some techniques of the most recent interventional radiology are very useful for the treatment of metastatic liver cancer and changing the style of hepatic infusion chemotherapy. This report shows our latest results and methods of hepatic infusion chemotherapy for metastatic liver cancer. 1. For the catheter placement, a new catheterization route via the left subclavian artery into the hepatic artery was developed and performed in 132 cases. Superselective catheterization succeeded in 123 cases (93.2 %). This procedure is less invasive than laparotomy and less troublesome than other percutaneous routes. 2. For useful infusion system, an implantable injection port ''Reservoir'' was developed and it was used in 87 cases. This method makes arterial infusion chemotherapy easy, and imploves their quality of life. 3. To acquire adequate drug delivery, arterial redistribution by steel coils was done, and 109 arteries in 80 cases were occluded. This method is very useful to make multiple hepatic artery single and it is important to avoid gasroduodenal complications. 4. Now, using these techniques, the phase II study of 5FU, ADM, MMC combined hepatic infusion in patients with non-resectable metastatic liver cancer is done. Up to this time, such a phase study on arterial infusion chemotherapy was difficult because of technical problems, but these new techniques make it possible. In conclusion, these new methods change the style and conception of hepatic infusion, and these make much progress on the treatment of patients with metastatic liver cancer. (author)

  20. Ultras-stable Physical Vapor Deposited Amorphous Teflon Films with Extreme Fictive Temperature Reduction

    Science.gov (United States)

    McKenna, Gregory; Yoon, Heedong; Koh, Yung; Simon, Sindee

    In the present work, we have produced highly stable amorphous fluoropolymer (Teflon AF® 1600) films to study the calorimetric and relaxation behavior in the deep in the glassy regime. Physical vapor deposition (PVD) was used to produce 110 to 700 nm PVD films with substrate temperature ranging from 0.70 Tg to 0.90 Tg. Fictive temperature (Tf) was measured using Flash DSC with 600 K/s heating and cooling rates. Consistent with prior observations for small molecular weight glasses, large enthalpy overshoots were observed in the stable amorphous Teflon films. The Tf reduction for the stable Teflon films deposited in the vicinity of 0.85 Tg was approximately 70 K compared to the Tgof the rejuvenated system. The relaxation behavior of stable Teflon films was measured using the TTU bubble inflation technique and following Struik's protocol in the temperature range from Tf to Tg. The results show that the relaxation time decreases with increasing aging time implying that devitrification is occurring in this regime.

  1. Effect of time duration of ruminal urea infusions on ruminal ammonia concentrations and portal-drained visceral extraction of arterial urea-N in lactating Holstein cows

    DEFF Research Database (Denmark)

    Røjen, Betina Amdisen; Kristensen, Niels Bastian

    2012-01-01

    investigated. Three Danish Holstein cows fitted with ruminal cannulas and permanent indwelling catheters in major splanchnic blood vessels were randomly allocated to a 3 × 3 Latin square design with 21-d periods. Treatments were ventral ruminal infusion of water for 24h (water INF), 24-h infusion of 15g...

  2. Microfluidic Pumps Containing Teflon [Trademark] AF Diaphragms

    Science.gov (United States)

    Willis, Peter; White, Victor; Grunthaner, Frank; Ikeda, Mike; Mathies, Richard A.

    2009-01-01

    Microfluidic pumps and valves based on pneumatically actuated diaphragms made of Teflon AF polymers are being developed for incorporation into laboratory-on-a-chip devices that must perform well over temperature ranges wider than those of prior diaphragm-based microfluidic pumps and valves. Other potential applications include implanted biomedical microfluidic devices, wherein the biocompatability of Teflon AF polymers would be highly advantageous. These pumps and valves have been demonstrated to function stably after cycling through temperatures from -125 to 120 C. These pumps and valves are intended to be successors to similar prior pumps and valves containing diaphragms made of polydimethylsiloxane (PDMS) [commonly known as silicone rubber]. The PDMS-containing valves ae designed to function stably only within the temperature range from 5 to 80 C. Undesirably, PDMS membranes are somwehat porous and retain water. PDMS is especially unsuitable for use at temperatures below 0 C because the formation of ice crystals increases porosity and introduces microshear.

  3. Catheter Angiography

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Catheter Angiography Catheter angiography uses a catheter, x-ray ... are the limitations of Catheter Angiography? What is Catheter Angiography? Angiography is a minimally invasive medical test ...

  4. Catheter Related Blood Stream Infections In Patients Of The Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Ana Carolina Coimbra de Castro

    2017-07-01

    Full Text Available Objective: To identify the prevalence of bloodstream infection associated with the Catheter related Blood stream infections in patients of the Intensive Care Unit, and the characteristics of its use and handling. Methods: Descriptive and transversal study with a sample of 88 participants. Data were collected through the observational method and the records in the medical records. The absolute and relative frequencies were used for data analysis. Results: 73.86% of the patients had central venous access in the subclavian vein, 100% used double lumen Catheter related Blood stream infections, 0.5% chlorhexidine solution for skin antisepsis, dressing coverage is performed mostly with Sterile gauze and tape, with a daily exchange. The rate of infection related to the use of the Catheter related Blood stream infections was (6.81%. The most infused pharmacological drugs were antimicrobials (69.32%. Conclusion: The study showed that care with central venous accesses is performed according to recommendations for prevention of bloodstream infection related to the use of these devices. The infection rate is close to the standards found in the literature. Key words: Central Venous Catheterization. Hospital Infection. Intensive care unit. Risk factors. Catheter-Related Infection..

  5. Depressed left ventricular performance. Response to volume infusion in patients with sepsis and septic shock

    International Nuclear Information System (INIS)

    Ognibene, F.P.; Parker, M.M.; Natanson, C.; Shelhamer, J.H.; Parrillo, J.E.

    1988-01-01

    Volume infusion, to increase preload and to enhance ventricular performance, is accepted as initial management of septic shock. Recent evidence has demonstrated depressed myocardial function in human septic shock. We analyzed left ventricular performance during volume infusion using serial data from simultaneously obtained pulmonary artery catheter hemodynamic measurements and radionuclide cineangiography. Critically ill control subjects (n = 14), patients with sepsis but without shock (n = 21), and patients with septic shock (n = 21) had prevolume infusion hemodynamic measurements determined and received statistically similar volumes of fluid resulting in similar increases in pulmonary capillary wedge pressure. There was a strong trend (p = 0.004) toward less of a change in left ventricular stroke work index (LVSWI) after volume infusion in patients with sepsis and septic shock compared with control subjects. The LVSWI response after volume infusion was significantly less in patients with septic shock when compared with critically ill control subjects (p less than 0.05). These data demonstrate significantly altered ventricular performance, as measured by LVSWI, in response to volume infusion in patients with septic shock

  6. Specially trained registered nurses can safely manage epidural analgesia infusion in laboring patients.

    Science.gov (United States)

    Charles, Lenore A; Korejwa, Elise; Kent, Donna Curtis; Raniero, Debbie

    2015-06-01

    To discover evidence for defining the registered nurse's (RN's) role in the management of epidural analgesia in the labor and delivery setting. The Labor Epidural Nurse Safety (LENS) study consisted of two parts. The first part was a 10-year retrospective review of the outcomes of 2,568 laboring women for whom epidural catheters had been placed and verified by an anesthesiologist or certified registered nurse anesthetist, then continuous epidural infusion initiated, and basal rate or patient-controlled epidural analgesia (PCEA) dose increased, if needed, within specified parameters by specially trained labor and delivery RNs. The second part compared the outcomes of the neonates born to the 2,568 women in the first part of the study with neonates born to mothers who received PCEA with a continuous infusion initiated and managed exclusively by anesthesiologists and/or certified registered nurse anesthetists at two control sites. Maternal outcomes were quantified by incidences of clinically significant hypotension and sentinel events, such as respiratory distress, cardio/respiratory distress, loss of consciousness, and seizures. Evidence of neonatal outcomes was collected by comparing Apgar scores. No sentinel events occurred, and there was no increase in maternal hypotensive events in the RN-managed group. There were no statistically significant differences in Apgar scores between the experimental and control groups. Specially trained RNs can safely initiate continuous infusions and increase the basal rate of epidural analgesia infusions or PCEA doses administered to laboring women, after insertion and confirmation of correct catheter placement by a qualified anesthesia provider, without adversely affecting maternal and fetal/neonatal outcomes. Copyright © 2015 American Society of PeriAnesthesia Nurses. Published by Elsevier Inc. All rights reserved.

  7. Trap-controlled charge transport in corona-charged Teflon

    International Nuclear Information System (INIS)

    Gross, B.; Giacometti, J.A.; Ferreira, G.F.L.; Moreno A, R.A.

    1980-01-01

    The stability of negatively charged Teflon electrets is discussed. It is stated that it can only be explained by the assumption that the transport of excess charge is trap - controlled rather than mobility - controlled. (I.C.R.) [pt

  8. Urinary catheters

    Science.gov (United States)

    Catheter - urine; Foley catheter; Indwelling catheter; Suprapubic catheters ... stones Blood infections ( septicemia ) Blood in the urine (hematuria) Kidney damage (usually only with long-term, indwelling ...

  9. Transarterial infusion chemotherapy with a combination of gemcitabine and 5-fluorouracil in advanced pancreatic carcinoma

    International Nuclear Information System (INIS)

    Shi Haifeng; Jin Zhengyu; Yang Ning; Liu Wei; Pan Jie; Cai Lixing; Zhao Yupei; Zhou Zhiqiang

    2002-01-01

    Objective: To retrospectively analyze the effectiveness of transarterial infusion chemotherapy of gemcitabine and 5-fluorouracil in advanced pancreatic carcinoma. Methods: Twenty-two patients with advanced pancreatic carcinoma were treated with transarterial infusion chemotherapy. Gemcitabine and 5-fluorouracil was administered to the patients via an interarterial catheter. Then the tumor response rate and clinical benefit were observed. Results: A clinical benefit was obtained in 8 patients (36.4%). The tumor response rate was 13.6%. Median survival for all the patients was 6.1 months. Median time to tumor progression was 2.9 months. Conclusion: Transarterial infusion chemotherapy with a combination of gemcitabine and 5-fluorouracil appears to have good clinical benefit and may prolong the survival time of patients with advanced pancreatic carcinoma

  10. Plastia da valva mitral com a técnica do "Duplo Teflon": resultados de 10 anos Mitral valve repair with "Double Teflon" technique: 10-year results

    Directory of Open Access Journals (Sweden)

    Carlos Manuel de Almeida Brandão

    2007-12-01

    Full Text Available OBJETIVO: O objetivo deste trabalho é apresentar os resultados clínicos tardios da plástica da valva mitral com a técnica do "Duplo Teflon". MÉTODOS: A plástica de "Duplo Teflon" consiste em técnica de reparo mitral com ressecção quadrangular da cúspide posterior, anuloplastia segmentar com plicatura do anel com de fios com "pledgets" sobre uma tira de Teflon, e sutura borda a borda da cúspide. Entre abril de 1994 e dezembro de 2003, 133 pacientes com diagnóstico de insuficiência mitral degenerativa com alongamento ou rotura de cordas da cúspide posterior foram submetidos à plástica com esta técnica. A idade média foi de 60,4 anos e 60,9% eram do sexo feminino. Quanto à avaliação clínica no pré-operatório, 29,3% dos pacientes estavam em classe funcional IV, 55,7% em classe III e 15,0% em classe II. Técnicas associadas de plástica mitral foram utilizadas em 15,2% dos pacientes, sendo a mais comum o encurtamento de cordas. Vinte e seis (19,5% pacientes foram submetidos a operações associadas. RESULTADOS: Houve um (0,75% óbito hospitalar. No período pós-operatório tardio, 95,5% dos sobreviventes estavam em classe funcional I. As taxas linearizadas de tromboembolismo, reoperação e óbito foram 0,9%, 0,3% e 0,6% pacientes/ano, respectivamente. A sobrevida atuarial em 10 anos foi de 94,1% ± 3,6%. As sobrevidas atuariais livre de tromboembolismo e reoperação foram de 97,3 ± 1,5% e 99,2 ± 0,8%, respectivamente. Não houve casos de endocardite ou hemólise. CONCLUSÃO: A plástica da valva mitral com a técnica do "Duplo Teflon" apresenta baixa morbi-mortalidade e boa evolução clínica tardia.OBJECTIVE: The purpose of this paper is to present the late clinical results of mitral valve repair with the "Double Teflon" technique. METHODS: "Double Teflon" technique consists of a quadrangular resection of the posterior leaflet, annulus plication with "pledgetted" stitches over a Teflon patch, and leaflet suture. Between

  11. Observation of the medium-long term efficacy of infusion chemotherapy in middle-terminal stage esophageal carcinomas

    International Nuclear Information System (INIS)

    Song Taimin; Han Xinwei; Wu Gang

    2005-01-01

    Objective: To explore the infusion chemotherapeutic efficacy and clinical application value for patients with middle-terminal stage esophageal carcinomas. Methods: Eighty patients with esophageal squamous carcinoma confirmed with barium meal examination and histopathology were undergone angiography and infusion chemotherapy through catheter in the target artery of the esophageal tumor. Results: Complete relief were acquired in 26 of 80 patients after the infusion, partial relief in 42, no-change in 11 and progress in 1; the overall effective rate was 85%(68/80). The survival rates was 87.5%(70/80), 38.8%(31/80), 21.3%(17/80), 15%(12/80) at 1, 2, 3 and 5 year intervals respectively. The patients of more than 3 years survival were complete symptomlessness after infusion. The survival rate could be improved significantly with infusion as long as necessary. Conclusions: The short-term efficacy with infusion is remarkable and should be the preferable choice, but the medium-long term survival rate is still low. Accomplishment with other therapies is further to be recommended. (authors)

  12. Central venous catheters: detection of catheter complications and therapeutical options

    International Nuclear Information System (INIS)

    Gebauer, B.; Beck, A.; Wagner, H.J.; Vivantes-Kliniken, Hellersdorf und Prenzlauer Berg

    2008-01-01

    For modern medicine central venous catheters play an important role for diagnostic and therapeutic options. Catheter implantation, complication detection and therapy of catheter complications are an increasing demand for the radiologist. The review article provides an overview of different catheter types, their indications, advantages and disadvantages. Catheter malpositions are usually detectable in conventional X-ray. Most malpositions are correctable using interventional-radiological techniques. In addition therapeutical options for thrombotic complications (venous thrombosis, catheter occlusion, fibrin sheath) are discussed. In case of an infectious catheter complication, usually a catheter extraction and re-implantation is necessary

  13. Significant air embolism: A possibility even with collapsible intravenous fluid containers when used with rapid infuser system

    Directory of Open Access Journals (Sweden)

    Deepanjali Pant

    2010-01-01

    Full Text Available Significant venous air embolism may develop acutely during the perioperative period due to a number of causes such as during head and neck surgery, spinal surgery, improper central venous and haemodialysis catheter handling, etc. The current trend of using self collapsible intravenous (IV infusion bags instead of the conventional glass or plastic bottles has several advantages, one of thaem being protection against air embolism. We present a 56-year-old man undergoing kidney transplantation, who developed a near fatal venous air embolism during volume resuscitation with normal saline in collapsible IV bags used with rapid infuser system. To our knowledge, this problem with collapsible infusion bags has not been reported earlier.

  14. Significant air embolism: A possibility even with collapsible intravenous fluid containers when used with rapid infuser system

    Science.gov (United States)

    Pant, Deepanjali; Narani, Krishan Kumar; Sood, Jayashree

    2010-01-01

    Significant venous air embolism may develop acutely during the perioperative period due to a number of causes such as during head and neck surgery, spinal surgery, improper central venous and haemodialysis catheter handling, etc. The current trend of using self collapsible intravenous (IV) infusion bags instead of the conventional glass or plastic bottles has several advantages, one of thaem being protection against air embolism. We present a 56-year-old man undergoing kidney transplantation, who developed a near fatal venous air embolism during volume resuscitation with normal saline in collapsible IV bags used with rapid infuser system. To our knowledge, this problem with collapsible infusion bags has not been reported earlier. PMID:20532073

  15. Catheter Angiography

    Medline Plus

    Full Text Available ... Z Catheter Angiography Catheter angiography uses a catheter, x-ray imaging guidance and an injection of contrast material ... vessels in the body. Angiography is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging ( ...

  16. DETACHMENT OF HUMAN FIBROBLASTS FROM FEP-TEFLON SURFACES

    NARCIS (Netherlands)

    VANKOOTEN, TG; SCHAKENRAAD, JM; VANDERMEI, HC; BUSSCHER, HJ

    1991-01-01

    In this study a comparison is made between the detachment behavior of human fibroblasts adhered to hydrophobic FEP-Teflon (water contact angle 109 degrees) and to hydrophilic glass (water contact angle smaller than 15 degrees) during exposure to a laminar, incrementally loaded flow. Detachment from

  17. Taurolidine lock is superior to heparin lock in the prevention of catheter related bloodstream infections and occlusions.

    Directory of Open Access Journals (Sweden)

    Evelyn D Olthof

    Full Text Available Patients on home parenteral nutrition (HPN are at risk for catheter-related complications; mainly infections and occlusions. We have previously shown in HPN patients presenting with catheter sepsis that catheter locking with taurolidine dramatically reduced re-infections when compared with heparin. Our HPN population therefore switched from heparin to taurolidine in 2008. The aim of the present study was to compare long-term effects of this catheter lock strategy on the occurrence of catheter-related bloodstream infections and occlusions in HPN patients.Data of catheter-related complications were retrospectively collected from 212 patients who received HPN between January 2000 and November 2011, comprising 545 and 200 catheters during catheter lock therapy with heparin and taurolidine, respectively. We evaluated catheter-related bloodstream infection and occlusion incidence rates using Poisson-normal regression analysis. Incidence rate ratios were calculated by dividing incidence rates of heparin by those of taurolidine, adjusting for underlying disease, use of anticoagulants or immune suppressives, frequency of HPN/fluid administration, composition of infusion fluids, and duration of HPN/fluid use before catheter creation.Bloodstream infection incidence rates were 1.1/year for heparin and 0.2/year for taurolidine locked catheters. Occlusion incidence rates were 0.2/year for heparin and 0.1/year for taurolidine locked catheters. Adjusted incidence ratios of heparin compared to taurolidine were 5.9 (95% confidence interval, 3.9-8.7 for bloodstream infections and 1.9 (95% confidence interval, 1.1-3.1 for occlusions.Given that no other procedural changes than the catheter lock strategy were implemented during the observation period, these data strongly suggest that taurolidine decreases catheter-related bloodstream infections and occlusions in HPN patients compared with heparin.

  18. Urinary catheter - infants

    Science.gov (United States)

    Bladder catheter - infants; Foley catheter - infants; Urinary catheter - neonatal ... A urinary catheter is a small, soft tube placed in the bladder. This article addresses urinary catheters in babies. WHY IS ...

  19. "FOLEY CATHETER CERVICAL RIPENING WITH EXTRAAMNIOTIC INFUSION OF SALINE OR CORTICOSTEROIDS: A DOUBLE-BLIND, RANDOMIZED CONTROLLED STUDY"

    Directory of Open Access Journals (Sweden)

    A.Sh. Zafarghandi

    2004-10-01

    Full Text Available Induction of labor is one of the most common procedures during pregnancy. Various methods for cervical ripening and labor induction have been described in the obstetrics literature; but the role of corticosteroids in the process of labor is not entirely understood. This study challenged the possible role of corticosteroids in induction of labor by extra-amniotic injection through an inflated intracervical Foley balloon catheter. This randomized trial was conducted on 44 women with a single pregnancy, intact membranes, and an unfavorable cervix. They were randomly assigned to receive either 20 mg of dexamethasone in saline solution (study group, n=22 or saline solution only (control group, n=22 administered extra-amniotically through an intracervical inflated Foley balloon catheter. Eighteen (81.8% patients in the study group and 20 (90.9% in the control group entered the active phase of labor and were delivered vaginally. The mean time intervals between induction of labor to the active phase and between induction of labor to delivery were significantly shorter in the study group compared with those of the control group (3.3±2.1 hours vs. 9±4.7 hours, P<0.01, 5.7±3.4 hours vs. 6.9±4.7 hours, P<0.01, respectively. There was no maternal or fetal complication in study or control group. The intracervical Foley balloon catheter with extra-amniotic corticosteroids was more efficient in reducing the induction-to-delivery interval for termination of midtrimester pregnancies than the same Foley catheter with saline solution only. Cervical ripening with extra-amniotic corticosteroids possesses the advantages of simplicity, low cost, and lack of systemic or serious side effects.

  20. The Use of Neuraxial Catheters for Postoperative Analgesia in Neonates: A Multicenter Safety Analysis from the Pediatric Regional Anesthesia Network.

    Science.gov (United States)

    Long, Justin B; Joselyn, Anita S; Bhalla, Tarun; Tobias, Joseph D; De Oliveira, Gildasio S; Suresh, Santhanam

    2016-06-01

    Currently, there is limited evidence to support the safety of neuraxial catheters in neonates. Safety concerns have been cited as a major barrier to performing large randomized trials in this population. The main objective of this study is to examine the safety of neuraxial catheters in neonates across multiple institutions. Specifically, we sought to determine the incidence of overall and individual complications encountered when neuraxial catheters were used for postoperative analgesia in neonates. This was an observational study that used the Pediatric Regional Anesthesia Network database. Complications and adverse events were defined by the presence of at least 1 of the following intraoperative and/or postoperative factors: catheter malfunction (dislodgment/occlusion), infection, block abandoned (unable to place), block failure (no evidence of block), vascular (blood aspiration/hematoma), local anesthetic systemic toxicity, excessive motor block, paresthesia, persistent neurologic deficit, and other (e.g., intra-abdominal misplacement, tremors). Additional analyses were performed to identify the use of potentially toxic doses of local anesthetics. The study cohort included 307 neonates with a neuraxial catheter. There were 41 adverse events and complications recorded, resulting in an overall incidence of complications of 13.3% (95% confidence interval, 9.8%-17.4%). Among the complications, catheter malfunction, catheter contamination, and vascular puncture were common. None of the complications resulted in long-term complications and/or sequelae, resulting in an estimated incidence of any serious complications of 0.3% (95% confidence interval, 0.08%-1.8%). There were 120 of 307 patients who received intraoperative and/or postoperative infusions consistent with a potentially toxic local anesthetic dose in neonates. The incidence of potentially toxic local anesthetic infusion rates increased over time (P = 0.008). Neuraxial catheter techniques for intraoperative

  1. Local NSAID infusion inhibits satellite cell proliferation in human skeletal muscle after eccentric exercise

    DEFF Research Database (Denmark)

    Mikkelsen, U R; Langberg, H; Helmark, I C

    2009-01-01

    Despite the widespread consumption of nonsteroidal anti-inflammatory drugs (NSAIDs), the influence of these drugs on muscle satellite cells is not fully understood. The aim of the present study was to investigate the effect of a local NSAID infusion on satellite cells after unaccustomed eccentric...... exercise in vivo in human skeletal muscle. Eight young healthy males performed 200 maximal eccentric contractions with each leg. An NSAID was infused via a microdialysis catheter into the vastus lateralis muscle of one leg (NSAID leg) before, during, and for 4.5 h after exercise, with the other leg working...... cells (CD68(+) or CD16(+) cells) was not significantly increased in either of the legs 8 days after exercise and was unaffected by the NSAID. The main finding in the present study was that the NSAID infusion for 7.5 h during the exercise day suppressed the exercise-induced increase in the number...

  2. Synchrotron Vacuum Ultraviolet Light and Soft X-Ray Radiation Effects on Aluminized Teflon FEP Investigated

    Science.gov (United States)

    Dever, Joyce A.; Townsend, Jacqueline A.; Gaier, James R.; Jalics, Alice I.

    1999-01-01

    Since the Hubble Space Telescope (HST) was deployed in low Earth orbit in April 1990, two servicing missions have been conducted to upgrade its scientific capabilities. Minor cracking of second-surface metalized Teflon FEP (DuPont; fluorinated ethylene propylene) surfaces from multilayer insulation (MLI) was first observed upon close examination of samples with high solar exposure retrieved during the first servicing mission, which was conducted 3.6 years after deployment. During the second HST servicing mission, 6.8 years after deployment, astronaut observations and photographic documentation revealed significant cracks in the Teflon FEP layer of the MLI on both the solar- and anti-solar-facing surfaces of the telescope. NASA Goddard Space Flight Center directed the efforts of the Hubble Space Telescope MLI Failure Review Board, whose goals included identifying the low-Earth-orbit environmental constituent(s) responsible for the cracking and embrittling of Teflon FEP which was observed during the second servicing mission. The NASA Lewis Research Center provided significant support to this effort. Because soft x-ray radiation from solar flares had been considered as a possible cause for the degradation of the mechanical properties of Teflon FEP (ref. 1), the effects of soft xray radiation and vacuum ultraviolet light on Teflon FEP were investigated. In this Lewisled effort, samples of Teflon FEP with a 100-nm layer of vapor-deposited aluminum (VDA) on the backside were exposed to synchrotron radiation of various vacuum ultraviolet and soft x-ray wavelengths between 18 nm (69 eV) and 0.65 nm (1900 eV). Synchrotron radiation exposures were conducted using the National Synchrotron Light Source at Brookhaven National Laboratory. Samples of FEP/VDA were exposed with the FEP surface facing the synchrotron beam. Doses and fluences were compared with those estimated for the 20-yr Hubble Space Telescope mission.

  3. Catheter Angiography

    Medline Plus

    Full Text Available ... of a catheter makes it possible to combine diagnosis and treatment in a single procedure. Catheter angiography ... of a catheter makes it possible to combine diagnosis and treatment in a single procedure. An example ...

  4. Catheter Angiography

    Medline Plus

    Full Text Available ... few millimeters) in the skin where the catheter can be inserted into an artery. The catheter is ... need for surgery. If surgery remains necessary, it can be performed more accurately. Catheter angiography presents a ...

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... resonance imaging (MRI) In catheter angiography, a thin plastic tube, called a catheter , is inserted into an ... The catheter used in angiography is a long plastic tube about as thick as a strand of ...

  6. Comparison of topical administration of clotrimazole through surgically placed versus nonsurgically placed catheters for treatment of nasal aspergillosis in dogs: 60 cases (1990-1996)

    International Nuclear Information System (INIS)

    Mathews, K.G.; Davidson, A.P.; Koblik, P.D.; Richardson, E.F.; Komtebedde, J.; Pappagianis, D.; Hector, R.F.; Kass, P.H.

    1998-01-01

    To examine the clinical response to topical administration of clotrimazole in dogs with nasal aspergillosis, to compare effect of surgically placed versus nonsurgically placed catheters used for administration on outcome, and to examine whether subjective scoring of computed tomographic images can predict outcome. Retrospective case series. 60 dogs with nasal aspergillosis. Information including signalment, history, diagnostics, treatment method, and outcome was retrieved from medical records of dogs with nasal aspergillosis treated between 1990 and 1996 at the University of California School of Veterinary Medicine or cooperating referral practices. Final outcome was determined by telephone conversations with owners and referring veterinarians. Images obtained before treatment were subjectively assessed to develop an algorithm for predicting outcome. Clotrimazole solution (1%) was infused during a 1-hour period via catheters surgically placed in the frontal sinus and nose (27 dogs) and via nonsurgically placed catheters in the nose (18). An additional 15 dogs received 2 to 4 infusions by either route. Topical administration of clotrimazole resulted in resolution of clinical disease in 65% of dogs after 1 treatment and 87% of dogs after one or more treatments. The scoring system correctly classified dogs with unfavorable and favorable responses 71 to 78% and 79 to 93% of the time, respectively. Topical administration of clotrimazole, using either technique, was an effective treatment for nasal aspergillosis in dogs. Use of non-invasive intranasal infusion of clotrimazole eliminated the need for surgical trephination of frontal sinuses in many dogs and was associated with fewer complications

  7. Infusion of butyrate affects plasma glucose, butyrate, and ß-hydroxybutyrate but not plasma insulin in lactating dairy cows

    Science.gov (United States)

    The objective of this research was to investigate the effects on plasma metabolites and rumen measures when butyrate was infused into the rumen or abomasum of lactating cows. Jugular catheters were inserted into 5 ruminally fistulated Holstein cows (94.2 ± 26.3 days in milk [DIM]; 717 ± 45 kg body w...

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a thin plastic ... called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of a catheter makes it ...

  9. First pass effect by infusing 99mTc-human serum albumin into the hepatic artery

    International Nuclear Information System (INIS)

    Ozawa, Takashi; Kimura, Kousaburou; Koyanagi, Yasuhisa

    1988-01-01

    The fundamental principles of intra-arterial infusion chemotherapy are thought to be increased local drug concentration and the ''first-pass'' effect. The concentration in the rest of the body can only be decreased if there is local elimination of the infused drug before reaching the systemic circulation. This is referred to as the ''first-pass'' effect. In the evaluation of ''first-pass'' effect, the uptake of liver after infusing 99m Tc-human serum albumin ( 99m Tc-HSA) in the hepatic artery by injecting the subcutaneously implanted silicon reservoir was compared with that obtained after intravenous administration of 99m Tc-HSA. In order to remove the factor of portal infusion, each count of liver up take had been continued for only 24 seconds after starting the liver uptake. The results are as follows : for 24 cases excepting 6 cases with catheter obstruction, the mean i.a./i.v. ratio was 7.92 ± 3.34 (range 3.25 to 17.25). Although the elimination rate of drugs in the liver varies with each drug, the infusion of intraarterial chemotherapy should be about 8 times more concentrative than intravenous administration on the ''first-pass'' effect. (author)

  10. Phlebitis associated with peripheral intravenous catheters in adults admitted to hospital in the Western Brazilian Amazon.

    Science.gov (United States)

    Enes, Sandra Maria Sampaio; Opitz, Simone Perufo; Faro, André Ricardo Maia da Costa de; Pedreira, Mavilde de Luz Gonçalves

    2016-04-01

    To identify the presence of phlebitis and the factors that influence the development of this complication in adult patients admitted to hospital in the western Brazilian Amazon. Exploratory study with a sample of 122 peripheral intravenous catheters inserted in 122 patients in a medical unit. Variables related to the patient and intravenous therapy were analyzed. For the analysis, we used chi-square tests of Pearson and Fisher exact test, with 5% significance level. Complication was the main reason for catheter removal (67.2%), phlebitis was the most frequent complication (31.1%). The mean duration of intravenous therapy use was 8.81 days in continuous and intermittent infusion (61.5%), in 20G catheter (39.3%), inserted in the dorsal hand vein arc (36.9 %), with mean time of usage of 68.4 hours. The type of infusion (p=0.044) and the presence of chronic disease (p=0.005) and infection (p=0.007) affected the development of phlebitis. There was a high frequency of phlebitis in the sample, being influenced by concomitant use of continuous and intermittent infusion of drugs and solutions, and more frequent in patients with chronic diseases and infection. Identificar a presença de flebite e os fatores que influenciam o desenvolvimento desta complicação em pacientes adultos internados em hospital da Amazônia Ocidental Brasileira. Estudo exploratório, com amostra de 122 cateteres intravenosos periféricos instalados em 122 pacientes de uma unidade de clínica médica. Foram analisadas variáveis relacionadas ao paciente e à terapia intravenosa. Para a análise utilizaram-se os testes de Qui-quadrado de Pearson e Exato de Fisher, com nível de significância de 5%. A complicação foi o principal motivo da retirada do cateter (67,2%), e a flebite a complicação mais frequente (31,1%). O tempo médio de uso de terapia intravenosa foi de 8,81 dias, em infusão contínua e intermitente (61,5%), em cateter calibre 20G (39,3%), inseridos nas veias do arco dorsal da m

  11. Combined conduction and radiation with phase change in teflon slabs

    International Nuclear Information System (INIS)

    Shih, T.M.; Hsu, I.C.; Cunnington, G.R. Jr.

    1986-01-01

    A new approach to investigate, numerically, an one-dimensional Stefan problem with combined radiation and conduction has been developed. This numerical scheme is a modified version of the heat flux method and the scheme tracks the moving phase changing interface by coordinate transformation. The physical problem involves the radiative heating on one side of a Teflon slab; causing the material to melt and sublime as the melt-solid interface recedes. The other side of the Teflon slab is insulated. The results of this numerical scheme has been compared with results reported in the literature; before attempting to use this scheme to predict the experimental data. Satisfactory agreement between numerical results and the results in the literature as well as the experimental data has been obtained in both comparisons

  12. Infraclavicular versus axillary nerve catheters: A retrospective comparison of early catheter failure rate.

    Science.gov (United States)

    Quast, Michaela B; Sviggum, Hans P; Hanson, Andrew C; Stoike, David E; Martin, David P; Niesen, Adam D

    2018-05-01

    Continuous brachial plexus catheters are often used to decrease pain following elbow surgery. This investigation aimed to assess the rate of early failure of infraclavicular (IC) and axillary (AX) nerve catheters following elbow surgery. Retrospective study. Postoperative recovery unit and inpatient hospital floor. 328 patients who received IC or AX nerve catheters and underwent elbow surgery were identified by retrospective query of our institution's database. Data collected included unplanned catheter dislodgement, catheter replacement rate, postoperative pain scores, and opioid administration on postoperative day 1. Catheter failure was defined as unplanned dislodging within 24 h of placement or requirement for catheter replacement and evaluated using a covariate adjusted model. 119 IC catheters and 209 AX catheters were evaluated. There were 8 (6.7%) failed IC catheters versus 13 (6.2%) failed AX catheters. After adjusting for age, BMI, and gender there was no difference in catheter failure rate between IC and AX nerve catheters (p = 0.449). These results suggest that IC and AX nerve catheters do not differ in the rate of early catheter failure, despite differences in anatomic location and catheter placement techniques. Both techniques provided effective postoperative analgesia with median pain scores < 3/10 for patients following elbow surgery. Reasons other than rate of early catheter failure should dictate which approach is performed. Copyright © 2018. Published by Elsevier Inc.

  13. The DSA diagnosis, artery embolization combined with low dose of vasopressin infusion treatment for lower digestive tract hemorrhage

    International Nuclear Information System (INIS)

    Huang Guoxin; Dou Yongchong; Zhang Yanfang; Shen Xinying; Xu Jianmin

    2005-01-01

    Objective: To evaluate the clinical value of digital subtraction angiography (DSA) diagnosis and interventional treatment for lower digestive tract hemorrhage of unknown reasons. Methods: DSA was performed in 32 patients with unknown etiologic lower digestive tract hemorrhage. The locations and causes of hemorrhage were determined by angiography according to the demonstration of contrast medium extravasation, abnormal vasculature and tumor staining. Superselective arterial embolization was performed with retaining catheter of low dose vasopressin infusion for 12 hours of hemostasis. Results: Seventy-five percent of the lesions were identified by DSA with 2 cases of intestinal typhoid, 1 intestinal tuberculosis, 14 cases of vascular malformation and 7 cases of tumor. Hemostasis was succeeded in 20 of 24 patients. The rate of success was 83.3%. Conclusions: DSA and interventional therapy are of great value in diagnosing and treating patients with lower digestive tract hemorrhage of unknown reasons and even those undergone unsuccessful conservative treatment. Low dose vasopressin infusion through retained catheter is safe and efficient after superselective arterial embolization. (authors)

  14. Nylon and teflon scribe effect on NBR to Chemlok 233 and NBR to NBR bond interfaces

    Science.gov (United States)

    Jensen, S. K.

    1990-01-01

    A study was requested by Manufacturing Engineering to determine what effects marking with nylon (6/6) and Teflon scribes may have on subsequent bonding. Witness panel bond specimens were fabricated by the development lab to test both acrylonitrile butadiene rubber (NBR) to Chemlok and NBR to NBR after controlled exposure. The nylon rod used as a scribe tool demonstrates virtually no bond deterioration when used to scribe lines on either the Chemlok to NBR surfaces or the NBR to NBR interface. Lab test results indicate that the nylon rod-exposed samples produce tensile and peel values very similar to the control samples and the Teflon exposed samples produce tensile and peel values much lower than the control samples. Visual observation of the failure surfaces of the tested samples shows that Teflon scribing produces an obvious contamination to the surface and the nylon produces no effect. Photographs of test samples are provided. It is concluded that Teflon stock used as a scribe tool on a Chemlok 233 to NBR surface or an NBR to NBR surface has a detrimental effect on the bond integrity on either of these bond interfaces. Therefore, it is recommended that the nylon rod continue to be used where a scribe line is required in the redesigned solid rocket motor segment insulation layup operations. The use of Teflon scribes should not be considered.

  15. Catheter Angiography

    Medline Plus

    Full Text Available ... lessen your anxiety during the procedure. The area of the groin or arm where the catheter will be inserted is shaved, ... contrast material is injected through the catheter and reaches the blood vessels being studied, several sets of x-rays are taken. Then the catheter is ...

  16. (Mis)placed central venous catheter in the left superior intercostal vein

    International Nuclear Information System (INIS)

    Padovan, Ranka Stern; Paar, Maja Hrabak; Aurer, Igor

    2010-01-01

    Chest X-ray is routinely performed to check the position of the central venous catheter (CVC) inserted through the internal jugular or subclavian vein, while the further evaluation of CVC malfunction is usually performed by contrast venography. In patients with superior vena cava obstruction, the tip of the catheter is often seen in collateral mediastinal venous pathways, rather than in the superior vena cava. In such cases detailed knowledge of thoracic vessel anatomy is necessary to identify the exact location of the catheter. We report a case of 32-year-old female patient with relapsing mediastinal lymphoma and previous superior vena cava obstruction with collateral azygos-hemiazygos venous pathways. The patient had CVC inserted through the left subclavian vein and its position was detected by CT to be in the dilated left superior intercostal vein and accessory hemiazygos vein. Considering that dilated accessory hemiazygos vein can tolerate infusion, the CVC was left in place and the patient had no complaints related to CVC (mal)position. Furthermore, we present anatomical and radiological observations on the azygos-hemiazygos venous system with the special emphasis on the left superior intercostal vein. Non-contrast CT scans can be a valuable imaging tool in the detection of the CVC position, especially in patients with renal insufficiency and contrast media hypersensitivity

  17. Hearing improvement after stapedotomy using teflon loop prosthesis

    International Nuclear Information System (INIS)

    Ahmed, S.; Raza, N.

    2006-01-01

    To assess hearing improvement after stapedotomy for otosclerosis using teflon loop prosthesis. Thirty diagnosed cases of otosclerosis were included in the study. Ear with greater air-bone gap was selected and stapedotomy was done using teflon loop prosthesis (size 4 - 4.5 mm). Mild vertigo occurred during immediate postoperative period, which subsided with Inj. Prochlorperazine. Patients were followed-up postsurgically at one month, two months, four months, six months and one year and postoperative air-bone gap was calculated. Out of 30 cases, there were 24 males and 06 females. The age ranged from 18 to 50 years. Twenty-one (70%) patients had bilateral hearing loss and 09 (30%) had tinnitis also. Pre-operative audiograms showed conductive deafness. Carhart's notch was present in 10 (33.3%) cases. Tympanogram revealed loss of stapedial reflex. Postoperatively good hearing improvement was seen in 56.7% (postoperative air-bone gap closure upto 10 dB), fair improvement in 30% (postoperative air bone gap closure from 11 to 20 dB) and poor results in 10% (postoperative air-bone gap more than 21 dB) cases. One patient developed dead ear. (author)

  18. Case Report of Serratus Plane Catheter for Pain Management in a Patient With Multiple Rib Fractures and an Inferior Scapular Fracture.

    Science.gov (United States)

    Fu, Peter; Weyker, Paul D; Webb, Christopher A J

    2017-03-15

    We placed a superficial serratus anterior plane catheter in an elderly woman with dementia and elevated clotting times who presented with multiple rib fractures after a mechanical fall. She was not a surgical candidate, and treatment consisted of conservative management with physical therapy and pain control. She was not a candidate for a patient-controlled analgesia regimen because of her dementia. Given her elevated international normalized ratio, thoracic epidural and paravertebral analgesia was also contraindicated. We placed an ultrasound-guided serratus anterior plane catheter, allowing titratable continuous infusion in a trauma patient, resulting in excellent analgesia without adverse effects.

  19. Phlebitis risk varies by peripheral venous catheter site and increases after 96 hours: a large multi-centre prospective study.

    Science.gov (United States)

    Cicolini, Giancarlo; Manzoli, Lamberto; Simonetti, Valentina; Flacco, Maria Elena; Comparcini, Dania; Capasso, Lorenzo; Di Baldassarre, Angela; Eltaji Elfarouki, Ghaleb

    2014-11-01

    This multi-centre prospective field study evaluated whether peripheral venous catheter site of insertion influences the risk of catheter-related phlebitis. Potential predictors of phlebitis were also investigated. Millions of patients worldwide use peripheral venous catheters, which frequently cause local complications including phlebitis, infection and obstruction. Although phlebitis predictors have been broadly investigated, uncertainties remain on the potential effect of cannulation anatomical site, duration and the appropriate time for catheter removal. A prospective cohort design was carried out from January-June 2012. The clinical course of each patient who received a new peripheral venous catheter for any cause in five Italian hospitals was followed by trained nurses until catheter removal. The presence of phlebitis was assessed every 24 hours using the Visual Infusion Phlebitis score. Analyses were based upon multilevel mixed-effects regression. The final sample consisted of 1498 patients. The average time for catheters in situ was 65·6 hours and 23·6% of the catheters were in place beyond 96 hours. Overall phlebitis incidence was 15·4%, 94·4% of which were grade 1. The likelihood of phlebitis independently increased with increasing catheter duration, being highest after 96 hours. Compared with patients with catheter placed in the dorsum of the hand (22·8% of the sample), those with the catheter located in the antecubital fossa (34·1%) or forearm were less likely to have a phlebitis of any grade. Antecubital fossa and forearm veins may be preferential sites for peripheral venous cannulation. Our results support Centers for Disease Control and Prevention recommendations to replace catheters in adults no later than 96 hours. A relevant proportion of healthcare personnel did not adhere to such guidelines - more attention to this issue is required. © 2014 John Wiley & Sons Ltd.

  20. Femtosecond laser ablation of polytetrafluoroethylene (Teflon) in ambient air

    International Nuclear Information System (INIS)

    Wang, Z.B.; Hong, M.H.; Lu, Y.F.; Wu, D.J.; Lan, B.; Chong, T.C.

    2003-01-01

    Teflon, polytetrafluorethylene (PTFE), is an important material in bioscience and medical application due to its special characteristics (bio-compatible, nonflammable, antiadhesive, and heat resistant). The advantages of ultrashort laser processing of Teflon include a minimal thermal penetration region and low processing temperatures, precision removal of material, and good-quality feature definition. In this paper, laser processing of PTFE in ambient air by a Ti:sapphire femtosecond laser (780 nm, 110 fs) is investigated. It is found that the pulse number on each irradiated surface area must be large enough for a clear edge definition and the ablated depth increases with the pulse number. The air ionization effect at high laser fluences not only degrades the ablated structures quality but also reduces the ablation efficiency. High quality microstructures are demonstrated with controlling laser fluence below a critical fluence to exclude the air ionization effect. The ablated microstructures show strong adhesion property to liquids and clear edges that are suitable for bio-implantation applications. Theoretical calculation is used to analyze the evolution of the ablated width and depth at various laser fluences

  1. Hubble Space Telescope Metallized Teflon(registered trademark) FEP Thermal Control Materials: On-Orbit Degradation and Post-Retrieval Analysis

    Science.gov (United States)

    Townsend, Jacqueline A.; Hansen, Patricia A.; Dever, J. A.; deGroh, K. K.; Banks, B.; Wang, L.; He, C.

    1988-01-01

    During the Hubble Space Telescope (HST) Second Servicing Mission (SM2), degradation of unsupported Teflon(Registered Trademark) FEP (fluorinated ethylene propylene), used as the outer layer of the multilayer insulation (MLI) blankets, was evident as large cracks on the telescope light shield. A sample of the degraded outer layer was retrieved during the mission and returned to Earth for ground testing and evaluation. The results of the Teflon(Registered Trademark) FEP sample evaluation and additional testing of pristine Teflon(Registered Trademark) FEP led the investigative team to theorize that the HST damage was caused by thermal cycling with deep-layer damage from electron and proton radiation which allowed the propagation of cracks along stress concentrations , and that the damage increased with the combined total dose of electrons, protons, UV and x-rays along with thermal cycling. This paper discusses the testing and evaluation of the retrieved Teflon(Registered Trademark) FEP.

  2. Influence of Teflon substrate on crystallization and enzymatic degradation of polymorphic poly(butylene adipate)

    DEFF Research Database (Denmark)

    Ning, Zhenbo; Nielsen, Ronnie Bo Højstrup; Zhao, Lifen

    2014-01-01

    for PBA beta crystals between neither the oriented nor the non-oriented Teflon films. The enzymatic degradation rate of PBA films was not determined by the epitaxial crystallization, in fact it was still dependent on the polymorphic crystal structure of PBA. The morphological changes of PBA films after...... enzymatic degradation confirmed again that the epitaxial crystallization only occurred for the PBA film with alpha crystal structure which was produced by being sandwiched between oriented Teflon films, and it happened only on the surface of PBA films....

  3. Efficacy of an Intrathecal Multidrug Infusion for Pain Control in Older Adults and in End-Stage Malignancies: A Report of Three Cases

    Directory of Open Access Journals (Sweden)

    Sadegh Abdolmohammadi

    2015-01-01

    Full Text Available The aim of the present study was to explore the effectiveness of an alternative method to manage pain based on a time-limited intrathecal (IT infusion of an analgesic medication mixture. Three patients (69, 64 and 94 years of age with intractable and poorly controlled pain due to bed sores, pelvic metastatic mass, and thoracic vertebra and rib fractures, respectively, were treated. Daily doses of opioids could not be increased due to side effects. An IT catheter (20 G was placed by percutaneous approach in the lumbar area while advancing toward the thoracic region, and was then tunnelled and fixed subcutaneously. It was connected to an external infusion pump with a mixture of bupivacaine 1 mg/mL, naloxone 0.02 ng/mL, ketamine 100 μg/mL, morphine 0.01 mg/mL and clonidine 0.75 μg/mL. The starting rate was 1 mL/h. The pain was mostly controlled at a rate of <1 mL/h. Opioid consumption was reduced dramatically. The catheter was kept in place for one month in the first and third patients, and for six months in the second patient, until his death. Major side effects, such as hypotension, constipation, muscle weakness, sphincter dysfunction, and cognitive or mood deterioration, were not observed with this approach. One patient experienced a urinary tract infection followed by sepsis and meningitis, which was cured by antibiotics. The catheter was removed in this patient. IT infusion with a low-concentration multidrug mixture could be considered as an alternative modality for intractable pain relief in older adults or in malignancies.

  4. Indwelling catheter care

    Science.gov (United States)

    Foley catheter ... You will need to make sure your indwelling catheter is working properly. You will also need to ... not get an infection or skin irritation. Make catheter and skin care part of your daily routine. ...

  5. Analysis of infusion-site reactions in renal transplant recipients receiving peripherally administered rabbit antithymocyte globulin as compared with basiliximab.

    Science.gov (United States)

    Erickson, Abbie L; Roberts, Keri; Malek, Sayeed K; Chandraker, Anil K; Tullius, Stefan G; Gabardi, Steven

    2010-06-01

    Antithymocyte globulin rabbit (r-ATG) has been used for the treatment and prevention of acute rejection in renal transplant recipients (RTR). Current manufacturer recommendations for r-ATG dictate the need for administration through a high-flow vein (central line). Previous studies have shown peripheral administration of r-ATG to be safe; however, these studies suggest the co-administration of heparin and hydrocortisone and did not compare the infusion-site reaction rates to a control group. A retrospective analysis was conducted of adult RTR receiving r-ATG or basiliximab between January 2004 and October 2006. Each agent was administered through a dedicated peripheral line. The primary endpoint was the incidence of infusion-site reactions. Other endpoints included the need to replace the intravenous catheter and the incidence of systemic thrombosis within 1 month of transplantation. During the study period, 152 peripheral infusions of r-ATG and 92 peripheral infusions of basiliximab were administered. No difference in infusion-site reactions was noted between the groups. There was also no difference either in the need for peripheral line replacement or the rates of systemic thrombosis. Peripheral administration of r-ATG is safe and can be infused without concomitant heparin and hydrocortisone. This method of r-ATG infusion was shown to be as safe as peripherally administered basiliximab.

  6. Milrinone via lumbar subarachnoid catheter for vasospasm after aneurysmal subarachnoid hemorrhage.

    Science.gov (United States)

    Sadamasa, Nobutake; Yoshida, Kazumichi; Narumi, Osamu; Chin, Masaki; Yamagata, Sen

    2014-12-01

    Delayed ischemic neurological deficit (DIND) due to symptomatic vasospasm is a major cause of morbidity and mortality after aneurysmal subarachnoid hemorrhage (aSAH). The aim of this study was to elucidate the safety and feasibility of intrathecal milrinone infusion via lumber subarachnoid catheter for prevention of DIND after aSAH. We diagnosed 425 consecutive patients with aSAH who received clipping or coil embolization within 48 h after arrival. Patients with the evidence of vasospasm on CT angiography (CTA) received the milrinone therapy via lumbar subarachnoid catheter. DIND, delayed cerebral infarction (DCI), and modified Rankin scale at 3 months after SAH were used for the assessment of outcome. Of 425 patients, 170 patients (40.0 %) with CTA-proven vasospasm received the milrinone therapy. DIND was observed in 68 patients (16.0 %), DCI in 30 patients (7.1 %), and the overall mortality was 7.2 %. In patients with WFNS grade IV and V aSAH, 26 out of 145 patients (17.9 %) were presented with DIND, 12 (8.3 %) with DCI, and the mortality was 16.0 %. No major complication related to the milrinone injection was observed. Intrathecal milrinone injection via lumbar catheter was safe and feasible, and further randomized prospective studies are needed to confirm the effectiveness of this regimen in the patients with SAH.

  7. Relationship between peripheral insertion site and catheter-related phlebitis in adult hospitalized patients: a systematic review.

    Science.gov (United States)

    Comparcini, Dania; Simonetti, Valentina; Blot, Stijn; Tomietto, Marco; Cicolini, Giancarlo

    2017-01-01

    To explore the relationship between the anatomical site of peripheral venous catheterization and risk of catheter-related phlebitis. Peripheral venous catheterization is frequently associated with phlebitis. Recent guidelines, recommend the use of an upper-extremity site for catheter insertion but no univocal consensus exists on the anatomical site with lower risk of phlebitis. Systematic review. We searched Medline (PubMed) and CINAHL (EBSCOhost) databases until the end of January 2017. We also reviewed the reference lists of retrieved articles and gray literature was excluded. Searches were limited to articles published in English with no restriction imposed to date of publication. The primary outcome was the incidence of phlebitis associated with anatomical site of peripheral catheterization. We included randomized controlled trials and observational studies on adult patients who required a peripheral catheter for the administration of medi- cation, intermittent or continuous fluid infusion. Antecubital fossa veins are associated with lower phlebitis rates, while hands veins are the most risky sites to develop phlebitis. There is no consensus regarding vein in forearm. Choosing the right anatomical site to insert a peripheral venous catheter is important to decrease phlebitis rate. Further studies should compare indwelling time in different anatomical sites with phlebitis rate. A more standardized approach in defining and assessing phlebitis among studies is recommended.

  8. The development and evaluation of a subcutaneous infusion delivery system based on osmotic pump control and gas drive.

    Science.gov (United States)

    Xie, Xiangyang; Yang, Yang; Yang, Yanfang; Li, Zhiping; Zhang, Hui; Chi, Qiang; Cai, Xingshi; Mei, Xingguo

    2016-09-01

    A novel, self-administration drug delivery system for subcutaneous infusion was developed and evaluated. The device includes two main components: an osmotic tablet controlled gas actuator and a syringe catheter system. The sodium carbonate in the osmotic pump tablet will release into the surround citric acid solution and produce CO 2 gas, which will drive the drug solution into subcutaneous tissue. The key formulation factors of the osmotic tablet that would influence the infusion profiles of the device were investigated by single factor exploration. The formulation was optimized via a response surface methodology. With an 18 ± 4 min of lag time, the delivery system was able to infuse at an approximate zero-order up to 5.90 ± 0.37 h with a precision of 9.0% RSD (n = 6). A linear correlation was found for the infusion profile and the fitting equation was Y = 0.014X - 0.004 (r = 0.998). A temperature change of 4 °C was found to modify the flow rate by about 12.0%. In vivo results demonstrated that the present subcutaneous infusion device was similar to the commercial infusion pump, and it could bring a long and constant ampicillin plasma level with minimized fluctuations.

  9. Insulin glulisine compared to insulin aspart and to insulin lispro administered by continuous subcutaneous insulin infusion in patients with type 1 diabetes: a randomized controlled trial

    NARCIS (Netherlands)

    van Bon, Arianne C.; Bode, Bruce W.; Sert-Langeron, Caroline; DeVries, J. Hans; Charpentier, Guillaume

    2011-01-01

    In a previous pilot study comparing insulin glulisine (GLU) with insulin aspart (ASP) administered by continuous subcutaneous insulin infusion (CSII), GLU-treated patients did show a trend toward fewer catheter occlusions compared with ASP-treated patients. Here we performed a randomized open-label,

  10. A randomized trial of automated intermittent ropivacaine administration vs. continuous infusion in an interscalene catheter

    DEFF Research Database (Denmark)

    Oxlund, J; Clausen, A H; Venø, S

    2018-01-01

    . Patients were allocated to either automated intermittent boluses with 16 mg ropivacaine every 2 h combined with patient-controlled administration or to a conventional regimen of continuous infusion of 8 mg/h (4 ml/h) of ropivacaine combined with patient controlled administration (2 ml, lockout time 30 min...

  11. Tracing Fasting Glucose Fluxes with Unstressed Catheter Approach in Streptozotocin Induced Diabetic Rats

    Directory of Open Access Journals (Sweden)

    Shichun Du

    2014-01-01

    Full Text Available Objective. Blood glucose concentrations of type 1 diabetic rats are vulnerable, especially to stress and trauma. The present study aimed to investigate the fasting endogenous glucose production and skeletal muscle glucose uptake of Streptozotocin induced type 1 diabetic rats using an unstressed vein and artery implantation of catheters at the tails of the rats as a platform. Research Design and Methods. Streptozotocin (65 mg·kg−1 was administered to induce type 1 diabetic state. The unstressed approach of catheters of vein and artery at the tails of the rats was established before the isotope tracer injection. Dynamic measurement of fasting endogenous glucose production was assessed by continuously infusing stable isotope [6, 6-2H2] glucose, while skeletal muscle glucose uptake by bolus injecting radioactively labeled [1-14C]-2-deoxy-glucose. Results. Streptozotocin induced type 1 diabetic rats displayed polydipsia, polyphagia, and polyuria along with overt hyperglycemia and hypoinsulinemia. They also had enhanced fasting endogenous glucose production and reduced glucose uptake in skeletal muscle compared to nondiabetic rats. Conclusions. The dual catheters implantation at the tails of the rats together with isotope tracers injection is a save time, unstressed, and feasible approach to explore the glucose metabolism in animal models in vivo.

  12. Recombinant human tripeptidyl peptidase-1 infusion to the monkey CNS: Safety, pharmacokinetics, and distribution

    Energy Technology Data Exchange (ETDEWEB)

    Vuillemenot, Brian R., E-mail: bvuillemenot@bmrn.com [BioMarin Pharmaceutical Inc., Novato, CA (United States); Kennedy, Derek [BioMarin Pharmaceutical Inc., Novato, CA (United States); Reed, Randall P.; Boyd, Robert B. [Northern Biomedical Research, Inc., Muskegon, MI (United States); Butt, Mark T. [Tox Path Specialists, LLC, Hagerstown, MD (United States); Musson, Donald G.; Keve, Steve; Cahayag, Rhea; Tsuruda, Laurie S.; O' Neill, Charles A. [BioMarin Pharmaceutical Inc., Novato, CA (United States)

    2014-05-15

    CLN2 disease is caused by deficiency in tripeptidyl peptidase-1 (TPP1), leading to neurodegeneration and death. The safety, pharmacokinetics (PK), and CNS distribution of recombinant human TPP1 (rhTPP1) were characterized following a single intracerebroventricular (ICV) or intrathecal-lumbar (IT-L) infusion to cynomolgus monkeys. Animals received 0, 5, 14, or 20 mg rhTPP1, ICV, or 14 mg IT-L, in artificial cerebrospinal fluid (aCSF) vehicle. Plasma and CSF were collected for PK analysis. Necropsies occurred at 3, 7, and 14 days post-infusion. CNS tissues were sampled for rhTPP1 distribution. TPP1 infusion was well tolerated and without effect on clinical observations or ECG. A mild increase in CSF white blood cells (WBCs) was detected transiently after ICV infusion. Isolated histological changes related to catheter placement and infusion were observed in ICV treated animals, including vehicle controls. The CSF and plasma exposure profiles were equivalent between animals that received an ICV or IT-L infusion. TPP1 levels peaked at the end of infusion, at which point the enzyme was present in plasma at 0.3% to 0.5% of CSF levels. TPP1 was detected in brain tissues with half-lives of 3–14 days. CNS distribution between ICV and IT-L administration was similar, although ICV resulted in distribution to deep brain structures including the thalamus, midbrain, and striatum. Direct CNS infusion of rhTPP1 was well tolerated with no drug related safety findings. The favorable nonclinical profile of ICV rhTPP1 supports the treatment of CLN2 by direct administration to the CNS. - Highlights: • TPP1 enzyme replacement therapy to the CNS is in development for CLN2 disease. • Toxicology, pharmacokinetics, and CNS distribution were assessed in monkeys. • TPP1 infusion directly to the brain did not result in any safety concerns. • A positive pharmacokinetic and distribution profile resulted from TPP1 infusion. • This study demonstrates the feasibility of ICV administered

  13. Recombinant human tripeptidyl peptidase-1 infusion to the monkey CNS: Safety, pharmacokinetics, and distribution

    International Nuclear Information System (INIS)

    Vuillemenot, Brian R.; Kennedy, Derek; Reed, Randall P.; Boyd, Robert B.; Butt, Mark T.; Musson, Donald G.; Keve, Steve; Cahayag, Rhea; Tsuruda, Laurie S.; O'Neill, Charles A.

    2014-01-01

    CLN2 disease is caused by deficiency in tripeptidyl peptidase-1 (TPP1), leading to neurodegeneration and death. The safety, pharmacokinetics (PK), and CNS distribution of recombinant human TPP1 (rhTPP1) were characterized following a single intracerebroventricular (ICV) or intrathecal-lumbar (IT-L) infusion to cynomolgus monkeys. Animals received 0, 5, 14, or 20 mg rhTPP1, ICV, or 14 mg IT-L, in artificial cerebrospinal fluid (aCSF) vehicle. Plasma and CSF were collected for PK analysis. Necropsies occurred at 3, 7, and 14 days post-infusion. CNS tissues were sampled for rhTPP1 distribution. TPP1 infusion was well tolerated and without effect on clinical observations or ECG. A mild increase in CSF white blood cells (WBCs) was detected transiently after ICV infusion. Isolated histological changes related to catheter placement and infusion were observed in ICV treated animals, including vehicle controls. The CSF and plasma exposure profiles were equivalent between animals that received an ICV or IT-L infusion. TPP1 levels peaked at the end of infusion, at which point the enzyme was present in plasma at 0.3% to 0.5% of CSF levels. TPP1 was detected in brain tissues with half-lives of 3–14 days. CNS distribution between ICV and IT-L administration was similar, although ICV resulted in distribution to deep brain structures including the thalamus, midbrain, and striatum. Direct CNS infusion of rhTPP1 was well tolerated with no drug related safety findings. The favorable nonclinical profile of ICV rhTPP1 supports the treatment of CLN2 by direct administration to the CNS. - Highlights: • TPP1 enzyme replacement therapy to the CNS is in development for CLN2 disease. • Toxicology, pharmacokinetics, and CNS distribution were assessed in monkeys. • TPP1 infusion directly to the brain did not result in any safety concerns. • A positive pharmacokinetic and distribution profile resulted from TPP1 infusion. • This study demonstrates the feasibility of ICV administered

  14. Catheter visualisation in MR tomography: first animal experimental experiences with field inhomogeneity catheters

    International Nuclear Information System (INIS)

    Adam, G.; Glowinski, A.; Neuerburg, J.; Buecker, A.; Vaals, J.J. van; Hurtak, W.; Guenther, R.W.

    1997-01-01

    Purpose: To assess the feasibility of a new developed field inhomogeneity catheter for interventional MR imaging in vivo. Materials and methods: Three different prototypes of a field inhomogeneity catheter were investigated in 6 pigs. The catheters were introduced in Seldinger technique via the femoral vessels over a guide wire on an interventional MR system (Philips Gyroscan NT combined with a C-arm fluoroscopy unit [Philips BV 212[). Catheters were placed in veins and arteries. The catheter position was controlled by a fast gradient echo sequence (Turbo Field Echo [TEF[). Results: Catheters were introduced over a guide wire without complications in all cases. Using the field inhomogeneity concept, catheters were easily visualised in the inferior vena cava and the aorta by the fast gradient echo technique on MR in all cases. Although aortic branches were successfully cannulated, the catheters were not displayed by the TFE technique due to the complex and tortuous anatomy. All animals survived the experiments without complications. Conclusion: MR guided visualisation of a field inhomogeneity catheter is a simple concept which can be realised on each MR scanner and may allow intravascular MR guided interventions in future. (orig.) [de

  15. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Catheter Angiography Catheter angiography ...

  16. Catheter Angiography

    Medline Plus

    Full Text Available ... imaging (MRI) In catheter angiography, a thin plastic tube, called a catheter , is inserted into an artery ... examined, a contrast material is injected through the tube and images are captured using a small dose ...

  17. Catheter Angiography

    Medline Plus

    Full Text Available ... incision in the skin. Once the catheter is guided to the area being examined, a contrast material ... inserted into an artery. The catheter is then guided through the arteries to the area to be ...

  18. Catheter Angiography

    Medline Plus

    Full Text Available ... catheter , is inserted into an artery through a small incision in the skin. Once the catheter is ... the tube and images are captured using a small dose of ionizing radiation ( x-rays ). top of ...

  19. Catheter Angiography

    Medline Plus

    Full Text Available ... it will make the rest of the procedure pain-free. You will not feel the catheter in ... nurse if you notice any bleeding, swelling or pain at the site where the catheter entered the ...

  20. Catheter Angiography

    Medline Plus

    Full Text Available ... should inform the nurse if you notice any bleeding, swelling or pain at the site where the ... Rarely, the catheter punctures the artery, causing internal bleeding. It also is possible that the catheter tip ...

  1. Catheter Angiography

    Medline Plus

    Full Text Available ... an artery through a small incision in the skin. Once the catheter is guided to the area ... small incision (usually a few millimeters) in the skin where the catheter can be inserted into an ...

  2. Catheter Angiography

    Medline Plus

    Full Text Available ... or other procedures such as chemoembolization or selective internal radiation therapy. identify dissection or splitting in the ... days. Rarely, the catheter punctures the artery, causing internal bleeding. It also is possible that the catheter ...

  3. Catheter Angiography

    Medline Plus

    Full Text Available ... is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, ... tumor; this is called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of ...

  4. Catheter Angiography

    Medline Plus

    Full Text Available ... Catheter angiography uses a catheter, x-ray imaging guidance and an injection of contrast material to examine ... removable dental appliances, eye glasses and any metal objects or clothing that might interfere with the x- ...

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... most cases, the kidneys will regain their normal function within five to seven days. Rarely, the catheter ... limitations of Catheter Angiography? Patients with impaired kidney function, especially those who also have diabetes, are not ...

  6. Catheter-related bloodstream infection.

    Science.gov (United States)

    Goede, Matthew R; Coopersmith, Craig M

    2009-04-01

    Catheter-related bloodstream infections (CR-BSIs) are a common, frequently preventable complication of central venous catheterization. CR-BSIs can be prevented by strict attention to insertion and maintenance of central venous catheters and removing unneeded catheters as soon as possible. Antiseptic- or antibiotic-impregnated catheters are also an effective tool to prevent infections. The diagnosis of CR-BSI is made largely based on culture results. CR-BSIs should always be treated with antibiotics, and except in rare circumstances the infected catheter needs to be removed.

  7. Catheter Angiography

    Medline Plus

    Full Text Available ... lies. The catheter used in angiography is a long plastic tube about as thick as a strand of spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ...

  8. Teflon injections in post-prostatectomy incontinence

    DEFF Research Database (Denmark)

    Osther, P J; Røhl, H F

    1988-01-01

    Twenty-five males with post-prostatectomy incontinence due to sphincter damage underwent transperineal or transurethral Teflon injections. The results were classified into three grades: good, moderate, and poor. Good or moderate results were obtained in 24%. No major immediate complications...... or longterm side-effects were observed. This intervention is associated with a minimum of discomfort for the patient and hospitalization can be limited to 48-72 hours. The results are not so good as those obtained in female incontinence, and the procedure cannot be recommended as first choice treatment...... in patients with post-prostatectomy incontinence, but because of the simplicity of the procedure, it is considered to be a valuable alternative in patients not suitable for prosthetic surgery....

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a ... tumor; this is called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of a ...

  10. A central venous catheter coated with benzalkonium chloride for the prevention of catheter-related microbial colonization.

    Science.gov (United States)

    Moss, H A; Tebbs, S E; Faroqui, M H; Herbst, T; Isaac, J L; Brown, J; Elliott, T S

    2000-11-01

    In an attempt to overcome infections associated with central venous catheters, a new antiseptic central venous catheter coated with benzalkonium chloride on the internal and external surfaces has been developed and evaluated in a clinical trial. Patients (235) randomly received either a triple-lumen central venous catheter coated with benzalkonium chloride (117) or a polyurethane non-antiseptic catheter (118). The incidence of microbial colonization of both catheters and retained antiseptic activity of the benzalkonium chloride device following removal were determined. The benzalkonium chloride resulted in a significant reduction of the incidence of microbial colonization on both the internal and external catheter surfaces. The reduction in colonization was detected at both the intradermal (21 benzalkonium chloride catheters vs. 38 controls, P = 0.0016) and distal segments of the antiseptic-coated catheters. Following catheter removal retained activity was demonstrated in benzalkonium chloride catheters which had been in place for up to 12 days. No patients developed adverse reactions to the benzalkonium chloride catheters. The findings demonstrate that the benzalkonium chloride catheter significantly reduced the incidence of catheter-associated colonization.

  11. Clinical usefulness of catheter-drawn blood samples and catheter tip cultures for the diagnosis of catheter-related bloodstream infections in neonatology: A systematic review.

    Science.gov (United States)

    Ferreira, Janita; Camargos, Paulo Augusto Moreira; Clemente, Wanessa Trindade; Romanelli, Roberta Maia de Castro

    2018-01-01

    Neonatal sepsis is the most frequent health care-associated infection in neonatal units. This study aimed to analyze articles on the clinical usefulness of catheter-drawn blood samples and catheter tip cultures for the diagnosis of intravascular catheter-related bloodstream infection (CRBSI) in neonates. A systematic search was performed for studies published from 1987-2017, without language restriction. Observational studies carried out in neonates with CRBSI diagnosed using catheter-drawn blood samples or catheter tip cultures were included. A total of 412 articles were identified in the databases and 10 articles were included. The 7 studies that evaluated central venous catheter tip cultures and cultures of catheter fragments presented sensitivities ranging from 58.5%-100% and specificities ranging from 60%-95.7%. Three studies that evaluated catheter-drawn blood cultures, paired with peripheral blood cultures, reported sensitivity and specificity of 94% and 71% when evaluated for the differential time to positivity. When quantitative evaluation was performed, the sensitivity and specificity were 80% and 99.4%. Most of the studies analyzed cultures from the central venous catheter tip and catheter fragments for the diagnosis of CRBSI in neonatal populations. The results of this review suggest that the analysis of the catheter-drawn blood samples and catheter tip cultures, paired with peripheral blood cultures, are efficient methods for the diagnosis of CRBSI in neonates. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  12. Fluoroscopically guided tunneled trans-caudal epidural catheter technique for opioid-free neonatal epidural analgesia.

    Science.gov (United States)

    Franklin, Andrew D; Hughes, Elisabeth M

    2016-06-01

    Epidural analgesia confers significant perioperative advantages to neonates undergoing surgical procedures but may be very technically challenging to place using a standard interlaminar loss-of-resistance to saline technique given the shallow depth of the epidural space. Thoracic epidural catheters placed via the caudal route may reduce the risk of direct neural injury from needle placement, but often pose higher risks of infection and/or improper positioning if placed without radiographic guidance. We present a detailed method of placing a fluoroscopically guided, tunneled transcaudal epidural catheter, which may reduce both of these risks. The accuracy and precision of this technique often provides adequate analgesia to allow for opioid-free epidural infusions as well as significant reductions in systemic opioids through the perioperative period. Opioid-free analgesia using a regional anesthetic technique allows for earlier extubation and reduced perioperative sedation, which may have a less deleterious neurocognitive effect on the developing brain of the neonate.

  13. Dedicated radial ventriculography pigtail catheter

    Energy Technology Data Exchange (ETDEWEB)

    Vidovich, Mladen I., E-mail: miv@uic.edu

    2013-05-15

    A new dedicated cardiac ventriculography catheter was specifically designed for radial and upper arm arterial access approach. Two catheter configurations have been developed to facilitate retrograde crossing of the aortic valve and to conform to various subclavian, ascending aortic and left ventricular anatomies. The “short” dedicated radial ventriculography catheter is suited for horizontal ascending aortas, obese body habitus, short stature and small ventricular cavities. The “long” dedicated radial ventriculography catheter is suited for vertical ascending aortas, thin body habitus, tall stature and larger ventricular cavities. This new design allows for improved performance, faster and simpler insertion in the left ventricle which can reduce procedure time, radiation exposure and propensity for radial artery spasm due to excessive catheter manipulation. Two different catheter configurations allow for optimal catheter selection in a broad range of patient anatomies. The catheter is exceptionally stable during contrast power injection and provides equivalent cavity opacification to traditional femoral ventriculography catheter designs.

  14. Can catheter-directed thrombolysis be applied to acute lower extremity artery embolism after recent cerebral embolism from atrial fibrillation?

    International Nuclear Information System (INIS)

    Si, T.-G.; Guo, Z.; Hao, X.-S.

    2008-01-01

    Purpose: To assess the feasibility and efficacy of catheter-directed thrombolysis with recombinant tissue plasminogen activator (rt-PA) for acute limb embolism in patients with recent cerebral embolism due to atrial fibrillation. Materials and methods: Eight patients (six men, two women; mean age 63.5 years) with acute embolic occlusion of two left common iliac arteries, four femoral arteries (three left; one right), and two right popliteal arteries were treated. All patients had a history of recent cerebral embolism (mean 6 days, range 5-15 days) and all had a history of atrial fibrillation (duration 5-10 years). Catheter-directed thrombolysis started a few hours (mean 6.2 h; range 3-10 h) after the onset of arterial embolism. Two 5 mg boluses of rt-PA were injected into the proximal clot through a 5 F end-hole catheter and, subsequently, two additional boluses of 5 mg rt-PA were injected into the emboli. In patients with residual emboli, infusion with rt-PA (1 mg/h) was continued. Percutaneous transluminal angioplasty was performed in three patients, and a stent was deployed in one patient. Results: Technical success was achieved in all patients. Clinical success rate was 87.5% (7/8). The one clinical failure was secondary to chronic occlusion of outflow runoff vessels. The mean duration of continuous rt-PA infusion was 3.6 h, the mean total dose of rt-PA administered was 23.6 mg (range 20-28 mg). There was no significant change in stroke scale scores during thrombolysis and no intracerebral haemorrhage was found at computed tomography (CT) after thrombolysis. Minor complications included haematomata at puncture sites (6/8), bleeding around the vascular sheath (2/8), and haematuria (1/8). During the follow-up period of 3-6 months, one patient suffered from recurrent cerebral embolism and died. Conclusions: Catheter-directed thrombolysis with rt-PA is an option for acute lower extremity arterial embolism in patients with recent cerebral embolism and a history of

  15. Can catheter-directed thrombolysis be applied to acute lower extremity artery embolism after recent cerebral embolism from atrial fibrillation?

    Energy Technology Data Exchange (ETDEWEB)

    Si, T.-G. [Department of interventional treatment, Tianjin medical university cancer Hospital and Institution, Tianjin (China); Guo, Z. [Department of interventional treatment, Tianjin medical university cancer Hospital and Institution, Tianjin (China)], E-mail: dr.guozhi@yahoo.com.cn; Hao, X.-S. [Department of interventional treatment, Tianjin medical university cancer Hospital and Institution, Tianjin (China)

    2008-10-15

    Purpose: To assess the feasibility and efficacy of catheter-directed thrombolysis with recombinant tissue plasminogen activator (rt-PA) for acute limb embolism in patients with recent cerebral embolism due to atrial fibrillation. Materials and methods: Eight patients (six men, two women; mean age 63.5 years) with acute embolic occlusion of two left common iliac arteries, four femoral arteries (three left; one right), and two right popliteal arteries were treated. All patients had a history of recent cerebral embolism (mean 6 days, range 5-15 days) and all had a history of atrial fibrillation (duration 5-10 years). Catheter-directed thrombolysis started a few hours (mean 6.2 h; range 3-10 h) after the onset of arterial embolism. Two 5 mg boluses of rt-PA were injected into the proximal clot through a 5 F end-hole catheter and, subsequently, two additional boluses of 5 mg rt-PA were injected into the emboli. In patients with residual emboli, infusion with rt-PA (1 mg/h) was continued. Percutaneous transluminal angioplasty was performed in three patients, and a stent was deployed in one patient. Results: Technical success was achieved in all patients. Clinical success rate was 87.5% (7/8). The one clinical failure was secondary to chronic occlusion of outflow runoff vessels. The mean duration of continuous rt-PA infusion was 3.6 h, the mean total dose of rt-PA administered was 23.6 mg (range 20-28 mg). There was no significant change in stroke scale scores during thrombolysis and no intracerebral haemorrhage was found at computed tomography (CT) after thrombolysis. Minor complications included haematomata at puncture sites (6/8), bleeding around the vascular sheath (2/8), and haematuria (1/8). During the follow-up period of 3-6 months, one patient suffered from recurrent cerebral embolism and died. Conclusions: Catheter-directed thrombolysis with rt-PA is an option for acute lower extremity arterial embolism in patients with recent cerebral embolism and a history of

  16. Comparative evaluation of the effect of silicone and teflon in prevention of epidural fibrosis after laminectomy in rat

    Directory of Open Access Journals (Sweden)

    Sheikh Rezaei A

    2001-08-01

    Full Text Available There are many studies about epidural fibrosis after surgical manipulation of the spine. We have studied formation of the post laminectomy epidural fibrosis after application of two materials (Silicone and Teflon in this report. This expriment is on two groups of rats. Two separated laminectomies were done in each rat, one serving as control while in the other laminectomy spaces Silicone was used in group A and Teflon in group B. Laminectomy spaces were evaluated with gross dissection and histologic studies after 6 weeks. Silicone decreased intermuscular scar, deep scar, dural adhesion and collagen fiber density in epidural space. Teflon decreased dural adhesion and collagen fiber density but did not decrease intermuscular and deep scar formation in epidural space.

  17. Catheter Angiography

    Medline Plus

    Full Text Available ... is injected through the catheter and reaches the blood vessels being studied, several sets of x-rays are taken. Then the catheter is removed and the incision site is closed by applying pressure on the area for approximately 10 to 20 ...

  18. Exercise-mediated vasodilation in human obesity and metabolic syndrome: effect of acute ascorbic acid infusion.

    Science.gov (United States)

    Limberg, Jacqueline K; Kellawan, J Mikhail; Harrell, John W; Johansson, Rebecca E; Eldridge, Marlowe W; Proctor, Lester T; Sebranek, Joshua J; Schrage, William G

    2014-09-15

    We tested the hypothesis that infusion of ascorbic acid (AA), a potent antioxidant, would alter vasodilator responses to exercise in human obesity and metabolic syndrome (MetSyn). Forearm blood flow (FBF, Doppler ultrasound) was measured in lean, obese, and MetSyn adults (n = 39, 32 ± 2 yr). A brachial artery catheter was inserted for blood pressure monitoring and local infusion of AA. FBF was measured during dynamic handgrip exercise (15% maximal effort) with and without AA infusion. To account for group differences in blood pressure and forearm size, and to assess vasodilation, forearm vascular conductance (FVC = FBF/mean arterial blood pressure/lean forearm mass) was calculated. We examined the time to achieve steady-state FVC (mean response time, MRT) and the rise in FVC from rest to steady-state exercise (Δ, exercise - rest) before and during acute AA infusion. The MRT (P = 0.26) and steady-state vasodilator responses to exercise (ΔFVC, P = 0.31) were not different between groups. Intra-arterial infusion of AA resulted in a significant increase in plasma total antioxidant capacity (174 ± 37%). AA infusion did not alter MRT or steady-state FVC in any group (P = 0.90 and P = 0.85, respectively). Interestingly, higher levels of C-reactive protein predicted longer MRT (r = 0.52, P exercise does not alter the time course or magnitude of exercise-mediated vasodilation in groups of young lean, obese, or MetSyn adults. However, systemic inflammation may limit the MRT to exercise, which can be improved with AA. Copyright © 2014 the American Physiological Society.

  19. Qualification of Magnesium/Teflon/Viton Pyrotechnic Composition Used in Rocket Motors Ignition System

    Directory of Open Access Journals (Sweden)

    Luciana de Barros

    2016-04-01

    Full Text Available The application of fluoropolymers in high-energy-release pyrotechnic compositions is common in the space and defense areas. Pyrotechnic compositions of magnesium/Teflon/Viton are widely used in military flares and pyrogen igniters for igniting the solid propellant of a rocket motor. Pyrotechnic components are considered high-risk products as they may cause catastrophic accidents if initiated or ignited inadvertently. To reduce the hazards involved in the handling, storage and transportation of these devices, the magnesium/Teflon/Viton composition was subjected to various sensitivity tests, DSC and had its stability and compatibility tested with other materials. This composition obtained satisfactory results in all the tests, which qualifies it as safe for production, handling, use, storage and transportation.

  20. FACTORS AND COMPLICATIONS AFFECTING CATHETER AND TECHNIQUE SURVIVAL WITH PERMANENT SINGLE-LUMEN DIALYSIS CATHETERS

    NARCIS (Netherlands)

    DEMEESTER, J; VANHOLDER, R; DEROOSE, J; RINGOIR, S

    1994-01-01

    This long-term study on the outcome of permanent silicone single-lumen dialysis catheters consisted of 43 surgically inserted catheters in 33 patients. All catheters were attached to a pressure-pressure single-cannula dialysis system. Technique and catheter survival were 80 and 59% at 1 year, and 63

  1. Changes in plasma calcium and in radiocalcium kinetics after termination of 5-week infusions of synthetic parathyroid peptide in dogs

    International Nuclear Information System (INIS)

    Stevenson, R.W.; Parsons, J.A.; Podbesek, R.D.; Reeve, J.

    1983-01-01

    Nine dogs were infused at constant rates with the synthetic parathyroid peptide hPTH 1-34 (initially sc) to produce consistent hypercalcaemia. Over the final week, the infusions were iv. Radioisotopic tracers were injected iv 30 days (5 dogs) and 2 days (9 dogs) before the infusions were suddenly terminated. In 5 dogs, complete urine collections were obtained via a bladder catheter over 8 h beginning 2 h before stopping the infusions. Cessation of treatment caused small rises in the urinary Ca: creatinine ratio. Plasma calcium levels fell by a mean of 0.44 mmol/l, of which total urine calcium excretion only accounted for 55%. Immediately after the PTH infusions were stopped, consistent but transient increases were seen in the ratio of ''new'' 47 Ca to ''old'' 45 Ca label, suggesting inflow of 40 Ca of high 47 Ca specific activity from a fairly rapidly exchangeable bone pool. These data confirm and extend previous evidence that the immediate response of the calcium equilibrium between bone and bloodstream to rapid changes in plasma PTH concentrations in the supra-physiological ranges is paradoxical relative to the classical later response. (author)

  2. Percutaneous central venous catheters versus peripheral cannulae for delivery of parenteral nutrition in neonates.

    Science.gov (United States)

    Ainsworth, S B; Clerihew, L; McGuire, W

    2007-07-18

    Parenteral nutrition for neonates may be delivered via a short peripheral cannula or a central venous catheter. The latter may either be inserted via the umbilicus or percutaneously. Because of the complications associated with umbilical venous catheter use, many neonatal units prefer to use percutaneously inserted catheters following the initial stabilisation period. The method of parenteral nutrition delivery may affect nutrient input and consequently growth and development. Although potentially more difficult to place, percutaneous central venous catheters may be more stable than peripheral cannulae, and need less frequent replacement. These delivery methods may also be associated with different risks of adverse events, including acquired systemic infection and extravasation injury. To determine the effect of infusion via a percutaneous central venous catheter versus a peripheral cannula on nutrient input, growth and development, and complications including systemic infection, or extravasation injuries in newborn infants who require parenteral nutrition. The standard search strategy of the Cochrane Neonatal Review Group was used. This included searches of the Cochrane Central Register of Controlled Trials (CENTRAL, The Cochrane Library, Issue 1, 2007), MEDLINE (1966 - February 2007), EMBASE (1980 - February 2007), conference proceedings, and previous reviews. Randomised controlled trials that compared the effect of delivering parenteral nutrition via a percutaneous central venous catheter versus a peripheral cannulae in neonates. Data were extracted the data using the standard methods of the Cochrane Neonatal Review Group, with separate evaluation of trial quality and data extraction by each author, and synthesis of data using relative risk, risk difference and mean difference. Four trials eligible for inclusion were found. These trials recruited a total of 368 infants and reported a number of different outcomes. One study showed that the use of a percutaneous

  3. Catheter versus non-catheter angiography in isolated third nerve palsy

    International Nuclear Information System (INIS)

    Lee, A.G.

    2007-01-01

    To discuss the controversies surrounding the indications for catheter angiography versus non-catheter and less invasive angiography techniques (e.g. magnetic resonance angiography (MRA) and computerized tomography angiography (CTA)) in the evaluation of patients with a third nerve palsy. Clinical opinion-perspective and literature review. The patient with an isolated third nerve palsy might have a vasculopathic (and typically benign, self limited course) etiology or a life threatening intracranial posterior communicating artery aneurysm. Although it is clear that non-isolated third nerve palsies require imaging directed at the topographical localization of the clinical findings, the evaluation of the neurologically isolated third nerve palsy remains controversial. The completeness of the external (i.e. somatic) motor dysfunction and the presence or absence of internal (i.e. pupillary) dysfunction are generally used to guide the choice of initial neuroimaging. Advances in MRA and CTA technology have reduced but not eliminated our dependence upon catheter angiography in this setting. A properly performed and interpreted MRA or CTA probably will be able to detect greater than 95 % of aneurysms producing a third nerve palsy. The issues surrounding the use of catheter angiography in third nerve palsy are reviewed. If the clinician is highly confident in the capability, availability, and reliability of the neuroradiologist and of their institutional experience and quality of less invasive non-catheter MRA and CTA and if the risk of aneurysm is low or if the risk of angiography is high (e.g. elderly, renal failure, iodinated contrast allergy, risk of stroke) then MRI and MRA (or CTA) may be a reasonable alternative to catheter angiography. Patients with a moderate or uncertain risk of aneurysm and a lower risk for catheter angiography or if there is a low confidence in the quality or the interpretation of the institutional MRA (or CTA) may still require catheter

  4. Efficacy and safety of rotating pigtail catheter: lower extremity deep vein thrombosis of may-thurner syndrome

    International Nuclear Information System (INIS)

    Kim, Yoon Kyung; Kang, Byung Chul; Gang, Sung Gown

    2004-01-01

    The purpose of this study was to evaluate the efficacy and safety of mechanical fragmentation of iliofemoral deep vein thromboses (DVTs) with a rotating pigtail catheter followed by aspiration thrombectomy. Ten patients (eight females, two males, 56.8 +/- 21.37 years) with iliofemoral DVT underwent treatment for a total of ten affected limbs. Approximately 5-10 min after infusing 400,000-700,000 IU urokinase (UK) into the thrombosed deep veins, the thromboses were fragmented by the mechanical action of the rotating pigtail catheter tip. Following their fragmentation, the fragmented thromboses were aspirated. After completion of the above procedure, a stent was inserted if iliac vein stenosis was demonstrated. We evaluated the total procedure time, volume of thrombolytic agent (urokinase), valvular injury, symptom-free time interval and success rate (primary patency rate). In all 10 patients, the iliofemoral deep vein thrombosis was successfully fragmented and aspirated using the combination method of a rotating pigtail catheter and aspiration thrombectomy (clinical and technical success rate, 100%). The thromboses were declotted by means of a rotating pigtail catheter with an average treatment time of 5.7 minutes. The average duration of the total intervention was 108 min. The mean primary patency was approximately 4 months with no recurrence. The total UK dose was 890,000 IU on average. There were no major complications, such as pulmonary embolism or cerebral hemorrhage, while performing the thrombus-fragmentation procedure using the rotating pigtail catheter. The combination method of a rotating pigtail catheter and aspiration thrombectomy for the treatment of iliofemoral deep vein thrombosis was found to be rapid, safe and effective for accomplishing recanalization in all cases without complication. Therefore, this procedure constitutes a potential treatment option in patients presenting with iliofemoral vein thrombosis

  5. Catheter-directed thrombolysis of below-knee deep venous thrombosis of the lower extremities

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Byung Suk; Sohn, Young Jun; Heo, Eun A; Cho, Hyun Sun; Park, Seong Hoon; Lee, Young Hwan [Wonkwang University Hospital, Iksan (Korea, Republic of)

    2008-02-15

    To evaluate the technical feasibility and clinical efficacy of the use of local thrombolysis for below-knee deep vein thrombosis (DVT). From a population of 41 patients with a lower extremity DVT, the prospective clinical trial included 11 patients (7 female, 4 male, average age 61.4 years) treated with catheter-directed thrombolysis with urokinase for below-knee DVT. After removal of the proximal ilofemoral DVT, additional interventional procedures to remove the residual thrombosis and restore the venous flow from the below-knee vein were performed in cases of continuous occlusion of venous flow from the popliteal and tibial veins. Under ultrasound (US) guidance, catheter-directed thrombolysis with urokinase was performed through the ipsilateral popliteal vein. After administration of oral anticoagulation therapy, CT and venography were performed to identify patency and the presence of a recurrent thrombosis. Successful removal of the thrombus and restoration of venous flow were achieved in all of the patients (100%). Restoration of flow with a residual thrombus occurred in one case. Focal venous stenosis was discovered in four cases. The duration of urokinase infusion was 1-4 days (average 2.36 days), which was considered long. For 15.2 months, the venous lumen of all cases was preserved without a recurrent thrombosis. Catheter-directed thrombolysis is an effective procedure for recanalization of below-knee DVT in patients with a lower extremity DVT.

  6. Catheter-directed thrombolysis of below-knee deep venous thrombosis of the lower extremities

    International Nuclear Information System (INIS)

    Roh, Byung Suk; Sohn, Young Jun; Heo, Eun A; Cho, Hyun Sun; Park, Seong Hoon; Lee, Young Hwan

    2008-01-01

    To evaluate the technical feasibility and clinical efficacy of the use of local thrombolysis for below-knee deep vein thrombosis (DVT). From a population of 41 patients with a lower extremity DVT, the prospective clinical trial included 11 patients (7 female, 4 male, average age 61.4 years) treated with catheter-directed thrombolysis with urokinase for below-knee DVT. After removal of the proximal ilofemoral DVT, additional interventional procedures to remove the residual thrombosis and restore the venous flow from the below-knee vein were performed in cases of continuous occlusion of venous flow from the popliteal and tibial veins. Under ultrasound (US) guidance, catheter-directed thrombolysis with urokinase was performed through the ipsilateral popliteal vein. After administration of oral anticoagulation therapy, CT and venography were performed to identify patency and the presence of a recurrent thrombosis. Successful removal of the thrombus and restoration of venous flow were achieved in all of the patients (100%). Restoration of flow with a residual thrombus occurred in one case. Focal venous stenosis was discovered in four cases. The duration of urokinase infusion was 1-4 days (average 2.36 days), which was considered long. For 15.2 months, the venous lumen of all cases was preserved without a recurrent thrombosis. Catheter-directed thrombolysis is an effective procedure for recanalization of below-knee DVT in patients with a lower extremity DVT

  7. Calculated energy dependence of CaSO4:Dy TL phosphor and phosphor embedded Teflon for X and gamma rays

    International Nuclear Information System (INIS)

    Chang, J.-K.; Nam, Y.-M.; Kim, J.-L.; Chang, S.-Y.; Kim, B.-H.

    2001-01-01

    The energy dependence of a CaSO 4 :Dy TL phosphor for 21 monoenergetic photons of energy ranging from 0.01 to 3 MeV was calculated by using MCNP4A code. The calculation results show good agreement with those of other authors within ± 5% relative error. Calculations and experiments are also performed to determine the energy dependence of CaSO 4 : Dy phosphor with Dy concentrations from 0.01 to 1.5 mol %, and with the compositions of TL-Teflon from 10 to 90 wt %. The calculated energy responses show good agreement with the experiment results within ± 20% relative error except for a concentration lower than 0.1 mol % Dy and the low energy regions of M30 (Eave.=20 keV) and M60 (Eave.=34 keV). For the TL-Teflon mixture, the energy dependence shows an decreasing trend with the increase of Teflon concentration in MCNP calculation but shows no dependence for TL-Teflon mixture proportions in experiment. These differences are due to the non-homogeneous distribution of Dy concentration and the effect of large grain size in the phosphors. The energy dependence of the 30 wt/o CaSO 4 (0.1 mol%;Dy) and 70 wt/o Teflon that is placed behind the filters of plastic, aluminum, copper, tin and lead with a thickness from 0.1 to 2 mm were calculated, respectively

  8. Impact of short-term hemodialysis catheters on the central veins: a catheter venographic study

    Energy Technology Data Exchange (ETDEWEB)

    Oguzkurt, Levent E-mail: loguzkurt@yahoo.com; Tercan, Fahri; Torun, Dilek; Yildirim, Tuelin; Zuemruetdal, Ayseguel; Kizilkilic, Osman

    2004-12-01

    Objective: To determine the incidence of pericatheter sleeve formation, thrombus formation, and stenosis of the central veins in hemodialysis patients with temporary catheters. Methods and material: In this prospective study, 57 patients (40 males, 17 females) with temporary dialysis catheters had catheter venography by pulling back the catheter just before removal. Patient's age range was 25-87 years (mean age, 51 years). The venographic studies were evaluated for pericatheter sleeve formation, thrombus formation, and stenosis of the brachiocephalic vein (BCV) and the superior vena cava (SVC). The IJV could only be evaluated if there was adequate filling during contrast administration. In a subgroup of patients who had had only right IJV or only right SCV catheters, impact of these catheters on the central veins was compared. Results: The catheter location was right internal jugular vein (IJV) in 26 cases, right subclavian vein (SCV) in 27 cases, left IJV in 1 case, and left SCV in 3 cases. Thirty-two patients (56%) had had only one temporary catheter and the rest had had more than one inserted. The mean dwell time for the catheters was 21 days (range 7-59 days). A pericatheter sleeve was detected on venography in 32 (56%) patients and thrombus formation was noted in 16 patients (28%). A total of 41 patients (72%) exhibited pericatheter sleeve and/or thrombus formation. While 19 of the 32 patients (59%) without previous catheterization had a sleeve around the catheter, only 13 (52%) of 25 patients who had had multiple catheters inserted had a sleeve (P>0.05). Of the eight patients (14%) with BCV stenosis, two had >50% stenosis. Only one patient (2%) had mild stenosis of the SVC. Three patients out of 15 (20%) who had diagnostic venography for the IJV had severe stenosis of the vein. Pericatheter sleeve formation was more frequent in women (P<0.05). However, there were no statistical differences with respect to pericatheter sleeve formation, luminal filling

  9. Female urinary stress incontinence treated with Teflon injections

    DEFF Research Database (Denmark)

    Osther, P J; Røhl, H

    1987-01-01

    Twenty-six women with urinary stress incontinence underwent transperineal or transurethral Teflon injections. The results were classified into three grades (good, moderate, and poor). Good or moderate results were obtained in 50%. No major immediate complications or long-term side-effects were...... observed. This intervention is associated with a minimum of discomfort for the patient and hospitalization can be limited to 48-72 h. The procedure can be carried out with good effect on women previously classically operated on without success and it does not prevent subsequent surgical intervention...

  10. Concurrent use of pigtail and loop snare catheters for percutaneous retrieval of dislodged central venous port catheter

    Directory of Open Access Journals (Sweden)

    Ming-Tsung Chuang

    2011-11-01

    Full Text Available The purpose of this study was to report our experience of percutaneous retrieval of dislodged port catheters with concurrent use of pigtail and loop snare catheters. During a 5-year period at our institute (June 2005 to July 2010, a total of 23 dislodged port catheters were retrieved. The interval between port catheter implantation and dislodged catheter retrieval ranged from 43 days to 1,414 days (mean 586.7 days. The time of delayed retrieval ranged from 1 day to 45 days (mean 4.6 days. All dislodged catheters were retrieved with the concurrent use of pigtail and loop snare catheters via femoral venous route. The prevalence of port catheter dislodgement at our institute was 3.4%. All dislodged port catheters were removed successfully with pigtail and loop snare catheters together. No procedure-related complications were encountered, except for transient arrhythmia in two patients, which required no medication. In conclusion, the concurrent use of pigtail and loop snare catheters is a feasible and easy way for percutaneous retrieval of a dislodged central venous port catheter.

  11. Placement of a peripherally inserted central catheter into the azygous vein

    Energy Technology Data Exchange (ETDEWEB)

    Franklin, Iain, E-mail: iain.franklin@health.qld.gov.au; Gilmore, Christopher [The Prince Charles Hospital, Brisbane, Queensland (Australia)

    2015-06-15

    Peripherally inserted central catheters (PICC) are used for a variety of infusion therapies. They are indicated in patients requiring long-term venous access. Incorrect positioning of the insertion of a PICC line is one of the known complications when inserting the device in clinical practice. Radiographers once performing imaging will commonly check if the tip of a PICC has entered the superior vena cava. This case study will report on a lesser known incorrect placement of a PICC line into the azygous vein and how this can be detected on radiographic imaging. This outcome for the patient can be detrimental as it has an increased risk of perforation, thrombus, and fistula formation.

  12. The efficacy of noble metal alloy urinary catheters in reducing catheter-associated urinary tract infection

    Directory of Open Access Journals (Sweden)

    Alanood Ahmed Aljohi

    2016-01-01

    Results: A 90% relative risk reduction in the rate of CAUTI was observed with the noble metal alloy catheter compared to the standard catheter (10 vs. 1 cases, P = 0.006. When considering both catheter-associated asymptomatic bacteriuria and CAUTI, the relative risk reduction was 83% (12 vs. 2 cases, P = 0.005. In addition to CAUTI, the risk of acquiring secondary bacteremia was lower (100% for the patients using noble metal alloy catheters (3 cases in the standard group vs. 0 case in the noble metal alloy catheter group, P = 0.24. No adverse events related to any of the used catheters were recorded. Conclusion: Results from this study revealed that noble metal alloy catheters are safe to use and significantly reduce CAUTI rate in ICU patients after 3 days of use.

  13. Button self-retaining drainage catheter

    International Nuclear Information System (INIS)

    Caridi, James G.; Hawkins, Irvin F.; Akins, E. William; Young, Ronald S.

    1997-01-01

    To help improve patient acceptance of long-term internal/external catheter access to the biliary tract in those with benign biliary obstruction, a simple design allows the catheter end to remain flush with the skin. It consists of a clothes button affixed to the drainage catheter with a wood screw after the catheter has been cut off at the skin exit. This button/screw device has been used successfully in 22 patients over the last 10 years; catheter exchanges were easily accomplished

  14. Disinfection of Biofilms in Tubes with Ultraviolet Light

    DEFF Research Database (Denmark)

    Bak, Jimmy; Begovic, Tanja

    2009-01-01

    Bacterial biofilms on long-term catheters are a major source of infection. We demonstrate here the potential of UVC light emitting diodes (LED) for disinfection purposes in catheter like tubes contaminated with biofilm. We show that UVC Light propagation is possible through teflon tubes using...... to a flow system and biofilms were produced during a three day period. Tubes in lengths of 10 cm (FEP teflon) were contaminated. Tubes for control and for UVC treatment were contaminated in parallel. The control and UVC treated tubes were both filled with a 20 % NaCl solution during the UVC treatment time...

  15. Delayed Migration and Perforation of the Jugular Vein by a Peripherally Inserted Central Catheter

    Directory of Open Access Journals (Sweden)

    Joshua J. Oliver

    2017-10-01

    Full Text Available We report a case of peripherally inserted central catheter (PICC migration and perforation of the left internal jugular vein in a home health setting in an 80-year-old female. A left sided PICC was placed for treatment of diverticulitis following hospital discharge. She complained of sudden onset left sided neck pain immediately after starting an infusion of vancomycin. In the emergency department the injury was identified by portable chest radiograph and computed tomography of her neck. Following removal of the line, she had an uneventful course. Emergency physicians should be aware of this possible PICC line complication.

  16. Infusion cisternography

    International Nuclear Information System (INIS)

    Magnaes, B.; Rootwelt, K.; Sjaastad, O.

    1976-01-01

    A source of error in cerebrospinal fluid (CSF) infusion tests is leakage at the dural puncture site. The addition of a bolus of radionuclide to the infusion fluid was helpful in detecting the existence of leakage as shown by increased infusion pressure in six of eight patients studied with and without scintigraphic evidence of leakage. Comparison of CSF dynamics in 26 patients studied by infusion cisternography and conventional cisternography showed similar patterns, suggesting no alteration of CSF dynamics by the artificial CSF infusion. Combining the two tests, therefore, resulted in simple identification of the leakage and saved the patient time and discomfort

  17. Pharmacokinetics and clinical efficacy of long-term epidural ropivacaine infusion in children

    DEFF Research Database (Denmark)

    Hansen, Tom Giedsing; Ilett, K F; Lim, S I

    2000-01-01

    The clinical efficacy and pharmacokinetics of long-term epidural ropivacaine infusion were investigated in 18 postoperative children aged between 0.3 and 7.3 yr. A lumbar or thoracic epidural catheter was inserted after the anaesthetic induction. Sixty minutes following a bolus dose of ropivacaine...... 1 mg kg-1, 0.2% ropivacaine was infused at a fixed rate of 0.4 mg kg-1 h-1 for a mean of 61.3 h (range 36-96 h). Clinical evaluation comprised hourly recording of pain, sedation, motor block, nausea/vomiting, pruritus-scores, SpO2, pulse and respiratory rates, and recording of non-invasive arterial......) and free (10-56 micrograms litre-1) ropivacaine concentrations were within the range reported to be 'safe' in previous studies in adults. Mean (95% CI) volume of distribution was 3.1 litre kg-1 (2.1-4.2 litre kg-1), total clearance was 8.5 ml kg-1 min-1 (5.8-11.1 ml kg-1 min-1), free clearance was 220 ml...

  18. Daily concurrent chemoradiotherapy using superselective intra-arterial infusion via superficial temporal artery. Preoperative therapy for stage III, IV oral cancer

    International Nuclear Information System (INIS)

    Tohnai, Iwai; Mitsudo, Kenji; Nishiguchi, Hiroaki; Fukui, Takafumi; Yamamoto, Noriyuki; Ueda, Minoru; Fuwa, Nobukazu

    2005-01-01

    Recently, daily concurrent chemoradiotherapy using new superselective intra-arterial infusion via superficial temporal arterial artery is attracting attention. The catheter with curved tip is inserted superselectively to the feeding artery of the tumor via the superficial temporal artery, allowing long-term catheterization. Forty-one patients with stage III, IV oral cancer were treated. Radiotherapy (total dose: 40 Gy/4 weeks) and superselective intra-arterial infusion chemotherapy using docetaxel (total dose: 60 mg/m 2 , 15 mg/m 2 /week) and cisplatin (total dose: 100 mg/m 2 , 5 mg/m 2 /day) were concurrently performed daily, followed by surgery. In 35 patients, intra-arterial infusion was successful (success rate: 85.4%) and no major complication was observed. The clinical effects were complete response (CR) in 29 patients (82.9%), and pathological effects of resected tumor after surgery were pathological CR in 31 (88.6%). This method promises to be a new strategy of choice for the treatment of oral cancer. (author)

  19. Exploring Imperfect Squeezing Flow Measurements in a Teflon Geometry for Semisolid Foods

    NARCIS (Netherlands)

    Terpstra, M.E.J.; Janssen, A.M.; Linden, van der E.

    2007-01-01

    The method of imperfect lubricated squeezing flow in a Teflon¿ geometry has been explored for the characterization of elongational behavior of custard and mayonnaise. Two Newtonian products, one of low (0.07 Pas) and one of high (18 Pas) shear viscosity, were used as references. Measurements of

  20. Exploring relationships of catheter-associated urinary tract infection and blockage in people with long-term indwelling urinary catheters.

    Science.gov (United States)

    Wilde, Mary H; McMahon, James M; Crean, Hugh F; Brasch, Judith

    2017-09-01

    To describe and explore relationships among catheter problems in long-term indwelling urinary catheter users, including excess healthcare use for treating catheter problems. Long-term urinary catheter users experience repeated problems with catheter-related urinary tract infection and blockage of the device, yet little has been reported of the patterns and relationships among relevant catheter variables. Secondary data analysis was conducted from a sample in a randomised clinical trial, using data from the entire sample of 202 persons over 12 months' participation. Descriptive statistics were used to characterise the sample over time. Zero-inflated negative binomial models were employed for logistic regressions to evaluate predictor variables of the presence/absence and frequencies of catheter-related urinary tract infection and blockage. Catheter-related urinary tract infection was marginally associated with catheter blockage. Problems reported at least once per person in the 12 months were as follows: catheter-related urinary tract infection 57%, blockage 34%, accidental dislodgment 28%, sediment 87%, leakage (bypassing) 67%, bladder spasms 59%, kinks/twists 42% and catheter pain 49%. Regression analysis demonstrated that bladder spasms were significantly related to catheter-related urinary tract infection and sediment amount, and catheter leakages were marginally significantly and positively related to catheter-related urinary tract infection. Frequencies of higher levels of sediment and catheter leakage were significantly associated with higher levels of blockage, and being female was associated with fewer blockages. Persons who need help with eating (more disabled) were also more likely to have blockages. Catheter-related urinary tract infection and blockage appear to be related and both are associated with additional healthcare expenditures. More research is needed to better understand how to prevent adverse catheter outcomes and patterns of problems in

  1. Intraileal casein infusion increases plasma concentrations of amino acids in humans: A randomized cross over trial.

    Science.gov (United States)

    Ripken, Dina; van Avesaat, Mark; Troost, Freddy J; Masclee, Ad A; Witkamp, Renger F; Hendriks, Henk F

    2017-02-01

    Activation of the ileal brake by casein induces satiety signals and reduces energy intake. However, adverse effects of intraileal casein administration have not been studied before. These adverse effects may include impaired amino acid digestion, absorption and immune activation. To investigate the effects of intraileal infusion of native casein on plasma amino acid appearance, immune activation and gastrointestinal (GI) symptoms. A randomized single-blind cross over study was performed in 13 healthy subjects (6 male; mean age 26 ± 2.9 years; mean body mass index 22.8 ± 0.4 kg/m -2 ), who were intubated with a naso-ileal feeding catheter. Thirty minutes after intake of a standardized breakfast, participants received an ileal infusion, containing either control (C) consisting of saline, a low-dose (17.2 kcal) casein (LP) or a high-dose (51.7 kcal) of casein (HP) over a period of 90 min. Blood samples were collected for analysis of amino acids (AAs), C-reactive protein (CRP), pro-inflammatory cytokines and oxylipins at regular intervals. Furthermore, GI symptom questionnaires were collected before, during and after ileal infusion. None of the subjects reported any GI symptoms before, during or after ileal infusion of C, LP and HP. Plasma concentrations of all AAs analyzed were significantly increased after infusion of HP as compared to C (p casein, respectively. Ileal casein infusion did not affect plasma concentrations of CRP, IL-6, IL-8, IL-1β and TNF-α. Infusion of HP resulted in a decreased concentration of 11,12-dihydroxyeicosatrienoic acid whereas none of the other oxylipins analyzed were affected. A single intraileal infusion of native casein results in a concentration and time dependent increase of AAs in plasma, suggesting an effective digestion and absorption of AAs present in casein. Also, ileal infusion did not result in immune activation nor in GI symptoms. CLINICALTRIALS.GOV: NCT01509469. Copyright © 2016 The Authors. Published by Elsevier

  2. Infusion Extractor

    Science.gov (United States)

    Chang-Diaz, Franklin R.

    1988-01-01

    Apparatus and method of removing desirable constituents from an infusible material by infusion extraction, where a piston operating in a first chamber draws a solvent into the first chamber where it may be heated, and then moves the heated solvent into a second chamber containing the infusible material, and where infusion extraction takes place. The piston then moves the solvent containing the extract through a filter into the first chamber, leaving the extraction residue in the second chamber.

  3. Local NSAID infusion does not affect protein synthesis and gene expression in human muscle after eccentric exercise

    DEFF Research Database (Denmark)

    Mikkelsen, U R; Schjerling, P; Helmark, Ida Carøe

    2010-01-01

    models, and inhibit the exercise-induced satellite cell proliferation and protein synthesis in humans. However, the cellular mechanisms eliciting these responses remain unknown. Eight healthy male volunteers performed 200 maximal eccentric contractions with each leg. To block prostaglandin synthesis...... locally in the skeletal muscle, indomethacin (NSAID) was infused for 7.5 h via microdialysis catheters into m. vastus lateralis of one leg. Protein synthesis was determined by the incorporation of 1,2-(13)C(2) leucine into muscle protein from 24 to 28 h post-exercise. Furthermore, mRNA expression...... of selected genes was measured in muscle biopsies (5 h and 8 days post-exercise) by real-time reverse transcriptase PCR. Myofibrillar and collagen protein synthesis were unaffected by the local NSAID infusion. Five hours post-exercise, the mRNA expression of cyclooxygenase-2 (COX2) was sixfold higher...

  4. A retrospective study of the hearing results obtained after stapedotomy by the implantation of two Teflon pistons with a different diameter

    NARCIS (Netherlands)

    Grolman, W.; Tange, R. A.; de Bruijn, A. J.; Hart, A. A.; Schouwenburg, P. F.

    1997-01-01

    This study reports the evaluation of hearing results after implantation of a Teflon piston of a different diameter in cases of otosclerosis requiring stapedotomy. By random selection, a Teflon piston with a shaft diameter of 0.3 mm was inserted in 34 cases and a piston with a shaft diameter of 0.4

  5. EFFECT OF TEFLON AND NAFION LOADING AT ANODE IN DIRECT FORMIC ACID FUEL CELL (DFAFC

    Directory of Open Access Journals (Sweden)

    M. S. MASDAR

    2016-08-01

    Full Text Available DFAFC has extensive hydrophilic nature and will cause problems in a limited mass transport in the anode side of electrode. Thus, the microporous layer (MPL of DFAFC needs a different in structure and morphology compared with that of PEMFC and DMFC because it will directly affect the performance. Therefore, in this study, the formulation of anode’s MPL has been investigated by varying the amount of Teflon and Nafion. Different loading of Teflon in MPL and Nafion in catalyst layer, i.e., 0 to 40% in weight, were used to fabricate the anode’s DFAFC. The characteristic of MPLs and anode (MPL with catalyst layer such as surface morphologies and resistivity, i.e., electrical impedance, have been analyzed using field emission scanning electron microscopy (FESEM and contact angle measurements as well as electrochemical impedance spectra (EIS. Meanwhile, the performance of fabricated anode was measured using cyclic voltammetry (CV technique with a half cell of DFAFC. From the result, it was obtained that the optimum content for both Teflon and Nafion on anode’s DFAFC was 20 wt% as shown in a highest electro-activity in electrode. The single cell DFAFC with optimum MEA formulation showed a good performance and hence, it is possible to apply the electricity power for electronic devices.

  6. Peritoneal catheter fixation combined with straight upward tunnel and low implant position to prevent catheter malfunction.

    Science.gov (United States)

    Zhang, Qingyan; Jiang, Chunming; Zhu, Wei; Sun, Cheng; Xia, Yangyang; Tang, Tianfeng; Wan, Cheng; Shao, Qiuyuan; Liu, Jing; Jin, Bo; Zhang, Miao

    2018-03-01

    Catheter malfunction is the main reason for early peritoneal dialysis (PD) technique failure. This study aimed to evaluate the effect of a new surgery technique with catheter fixation to the lower abdominal wall combined with straight upward tunnel and low implant position in reducing catheter malfunction. Patients with end stage renal disease who received PD in our centre from January 2013 to December 2015 were involved in this study. They were randomly divided into three groups according to surgical technique: traditional open surgery group, modified open surgery group and modified open surgery with catheter fixation group. All patients were followed up for six months after surgery. Catheter- related complications were analyzed. A total of 152 patients were involved. Among them, 49 received traditional open surgery (TOS group), 49 received modified open surgery (MOS group), and 54 received modified open surgery with catheter fixation (MOS-F group). During follow-up, no patients (0%) in MOS-F group developed catheter malfunction which was significantly lower than that of the TOS group (0 vs 16.33%, P = 0.002). Although not statistically significant, the incidence of catheter malfunction was lower in MOS-F group than that in MOS group (0 vs 4.08%, P = 0.134). No significant difference was observed in the episodes of infection, bleeding, leakage, inflow or outflow pain, hernia and delayed wound healing among the three groups (all P > 0.05). Catheter fixation combined with straight upward tunnel and low implant position can effectively prevent catheter malfunction in PD catheter placement. © 2016 Asian Pacific Society of Nephrology.

  7. Diuretic Agent and Normal Saline Infusion Technique for Ultrasound-Guided Percutaneous Nephrostomies in Nondilated Pelvicaliceal Systems

    International Nuclear Information System (INIS)

    Yagci, Cemil; Ustuner, Evren; Atman, Ebru Dusunceli; Baltaci, Sumer; Uzun, Caglar; Akyar, Serdar

    2013-01-01

    Percutaneous nephrostomy (PCN) in a nondilated pelvicaliceal system is technically challenging. We describe an effective method to achieve transient dilatation of the pelvicaliceal system via induction of diuresis using infusion of a diuretic agent in normal saline, therefore allowing easier access to the pelvicaliceal system. Under real-time ultrasound guidance, the technique had been tested in 22 nephrostomies with nondilated system (a total of 20 patients with 2 patients having bilateral nephrostomies) during a 5-year period. Patients were given 40 mg of furosemide in 250 ml of normal saline solution intravenously by rapid infusion. As soon as maximum calyceal dilatation of more than 5 mm was observed, which is usually 15 min later after the end of rapid infusion, patients were positioned obliquely, and PCN procedure under ultrasound guidance was performed. The procedure was successful in 19 of the nephrostomies in 17 patients with a success rate of 86.36 % per procedure and 85 % per patient in nondilated pelvicaliceal systems. No major nephrostomy-, drug-, or technique-related complications were encountered. The technique failed to work in three patients due to the presence of double J catheters and preexisting calyceal perforation which avoided transient dilation of the pelvicaliceal system with diuresis. Diuretic infusion in saline is a feasible and effective method for PCN in nondilated pelvicaliceal systems.

  8. Diuretic Agent and Normal Saline Infusion Technique for Ultrasound-Guided Percutaneous Nephrostomies in Nondilated Pelvicaliceal Systems

    Energy Technology Data Exchange (ETDEWEB)

    Yagci, Cemil, E-mail: cemil.yagci@medicine.ankara.edu.tr; Ustuner, Evren, E-mail: evrenustuner@hotmail.com; Atman, Ebru Dusunceli, E-mail: ebrumd2001@yahoo.com [Ankara University, Department of Radiology, School of Medicine (Turkey); Baltaci, Sumer, E-mail: sbaltaci@hotmail.com [Ankara University, Department of Urology, School of Medicine (Turkey); Uzun, Caglar, E-mail: cuzun77@yahoo.com; Akyar, Serdar, E-mail: yusuf.s.akyar@medicine.ankara.edu.tr [Ankara University, Department of Radiology, School of Medicine (Turkey)

    2013-04-15

    Percutaneous nephrostomy (PCN) in a nondilated pelvicaliceal system is technically challenging. We describe an effective method to achieve transient dilatation of the pelvicaliceal system via induction of diuresis using infusion of a diuretic agent in normal saline, therefore allowing easier access to the pelvicaliceal system. Under real-time ultrasound guidance, the technique had been tested in 22 nephrostomies with nondilated system (a total of 20 patients with 2 patients having bilateral nephrostomies) during a 5-year period. Patients were given 40 mg of furosemide in 250 ml of normal saline solution intravenously by rapid infusion. As soon as maximum calyceal dilatation of more than 5 mm was observed, which is usually 15 min later after the end of rapid infusion, patients were positioned obliquely, and PCN procedure under ultrasound guidance was performed. The procedure was successful in 19 of the nephrostomies in 17 patients with a success rate of 86.36 % per procedure and 85 % per patient in nondilated pelvicaliceal systems. No major nephrostomy-, drug-, or technique-related complications were encountered. The technique failed to work in three patients due to the presence of double J catheters and preexisting calyceal perforation which avoided transient dilation of the pelvicaliceal system with diuresis. Diuretic infusion in saline is a feasible and effective method for PCN in nondilated pelvicaliceal systems.

  9. A Simplified Technique of Percutaneous Hepatic Artery Port-Catheter Insertion for the Treatment of Advanced Hepatocellular Carcinoma with Portal Vein Invasion

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Sun Young [Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of); Kim, Ah Hyun; Lee, Do Yun; Lee, Kwang Hun; Won, Jong Yun [Yonsei University College of Medicine, Severance Hospital, Seoul (Korea, Republic of); Kim, Kyung Ah [Inje University Ilsan Paik Hospital, Ilsan (Korea, Republic of)

    2010-12-15

    We assessed the outcomes of a simplified technique for the percutaneous placement of a hepatic artery port-catheter system for chemotherapy infusion in advanced hepatocellular carcinoma with portal vein invasion. From February 2003 to February 2008, percutaneous hepatic artery port-catheter insertion was performed in 122 patients who had hepatocellular carcinoma with portal vein invasion. The arterial access route was the common femoral artery. The tip of the catheter was wedged into the right gastroepiploic artery without an additional fixation device. A side hole was positioned at the distal common hepatic artery to allow the delivery of chemotherapeutic agents into the hepatic arteries. Coil embolization was performed only to redistribute to the hepatic arteries or to prevent the inadvertent delivery of chemotherapeutic agents into extrahepatic arteries. The port chamber was created at either the supra-inguinal or infra-inguinal region. Technical success was achieved in all patients. Proper positioning of the side hole was checked before each scheduled chemotherapy session by port angiography. Catheter-related complications occurred in 19 patients (16%). Revision was achieved in 15 of 18 patients (83%). This simplified method demonstrates excellent technical feasibility, an acceptable range of complications, and is hence recommended for the management of advanced hepatocellular carcinoma with portal vein thrombosis

  10. [The role of the uretral catheter in the development of catheter- related urinary tract infection].

    Science.gov (United States)

    Vasilyev, A O; Govorov, A V; Shiryaev, A A; Pushkar, D Yu

    2017-12-01

    The most common source of nosocomial infection is the urinary tract, especially if they it is drained with a urethral catheter. Catheter-associated urinary tract infections account for at least 80% of all complicated urinary tract infections and are the most common type of hospital-acquired infection. Intestinal microflora plays the leading role in the pathogenesis of catheter-associated urinary tract infections, whereas the most important risk factor for their development is the long duration of urinary catheter drainage. In the case of short-term and intermittent catheterization, routine antibiotic prophylaxis is not required, but if a patient develops clinically significant infection, antibiotic therapy is required followed by definitive therapy based on culture. Urethral catheters coated with antimicrobial substances and anti-inflammatory agents can significantly reduce the adhesion and migration of bacteria, thereby reducing the incidence of urinary tract infections. Despite this, the incidence of catheter-associated infection remains high. We have reviewed recent literature related to catheter-associated urinary tract infections and the best means of preventing this condition.

  11. Epidural blood flow and regression of sensory analgesia during continuous postoperative epidural infusion of bupivacaine

    DEFF Research Database (Denmark)

    Mogensen, T; Højgaard, L; Scott, N B

    1988-01-01

    Epidural blood flow was measured in seven patients undergoing elective abdominal surgery during combined lumbar epidural and general anesthesia. After an initial dose of 20 ml plain bupivacaine 0.5%, a continuous epidural infusion of bupivacaine 0.5% (8 ml/hr) was given for 16 hours...... for postoperative pain relief. The epidural blood flow was measured by a local 133Xe clearance technique in which 15-35 MBq 133Xe diluted in 1 ml saline was injected through the epidural catheter on the day before surgery (no bupivacaine), 30 minutes after the initial dose of bupivacaine on the morning before...... surgery, and 8, 12, and 16 hours later during the continuous infusion. Initial blood flow was 6.0 +/- 0.7 ml/min per 100 g tissue (mean +/- SEM). After epidural bupivacaine, blood flow increased in all seven patients to 7.4 +/- 0.7 ml (P less than 0.02). Initial level of sensory analgesia was T4.5 +/- 0...

  12. Epidural Catheter Breakage In-Situ

    Directory of Open Access Journals (Sweden)

    Geetanjali S Verma

    2014-09-01

    Full Text Available A 45yr old woman diagnosed with dysfunctional uterine bleeding and incisional hernia was planned for total abdominal hysterectomy with bilateral salpingo-oophorectomy and mesh repair under combined spinal and epidural anaesthesia. Using VYGON® epidural catheter with its recommended introducer, the catheter was inserted but it snapped off at 11cm mark while positioning the catheter. After radiological confirmation, the neurosurgeon removed the catheter under general anaesthesia, which was followed by the scheduled surgery.

  13. UV and IR laser radiation's interaction with metal film and teflon surfaces

    Science.gov (United States)

    Fedenev, A. V.; Alekseev, S. B.; Goncharenko, I. M.; Koval', N. N.; Lipatov, E. I.; Orlovskii, V. M.; Shulepov, M. A.; Tarasenko, V. F.

    2003-04-01

    The interaction of Xe ([lambda] [similar] 1.73 [mu]m) and XeCl (0.308 [mu]m) laser radiation with surfaces of metal and TiN-ceramic coatings on glass and steel substrates has been studied. Correlation between parameters of surface erosion versus laser-specific energy was investigated. Monitoring of laser-induced erosion on smooth polished surfaces was performed using optical microscopy. The correlation has been revealed between characteristic zones of thin coatings damaged by irradiation and energy distribution over the laser beam cross section allowing evaluation of defects and adhesion of coatings. The interaction of pulsed periodical CO2 ([lambda] [similar] 10.6 [mu]m), and Xe ([lambda] [similar] 1.73 [mu]m) laser radiation with surfaces of teflon (polytetrafluoroethylene—PTFE) has been studied. Monitoring of erosion track on surfaces was performed through optical microscopy. It has been shown that at pulsed periodical CO2-radiation interaction with teflon the sputtering of polymer with formation of submicron-size particles occurs. Dependencies of particle sizes, form, and sputtering velocity on laser pulse duration and target temperature have been obtained.

  14. Incidence of catheter-related complications in patients with central venous or hemodialysis catheters: a health care claims database analysis.

    Science.gov (United States)

    Napalkov, Pavel; Felici, Diana M; Chu, Laura K; Jacobs, Joan R; Begelman, Susan M

    2013-10-16

    Central venous catheter (CVC) and hemodialysis (HD) catheter usage are associated with complications that occur during catheter insertion, dwell period, and removal. This study aims to identify and describe the incidence rates of catheter-related complications in a large patient population in a United States-based health care claims database after CVC or HD catheter placement. Patients in the i3 InVision DataMart® health care claims database with at least 1 CVC or HD catheter insertion claim were categorized into CVC or HD cohorts using diagnostic and procedural codes from the US Renal Data System, American College of Surgeons, and American Medical Association's Physician Performance Measures. Catheter-related complications were identified using published diagnostic and procedural codes. Incidence rates (IRs)/1000 catheter-days were calculated for complications including catheter-related bloodstream infections (CRBSIs), thrombosis, embolism, intracranial hemorrhage (ICH), major bleeding (MB), and mechanical catheter-related complications (MCRCs). Thirty percent of the CVC cohort and 54% of the HD cohort had catheter placements lasting <90 days. Catheter-related complications occurred most often during the first 90 days of catheter placement. IRs were highest for CRBSIs in both cohorts (4.0 [95% CI, 3.7-4.3] and 5.1 [95% CI, 4.7-5.6], respectively). Other IRs in CVC and HD cohorts, respectively, were thrombosis, 1.3 and 0.8; MCRCs, 0.6 and 0.7; embolism, 0.4 and 0.5; MB, 0.1 and 0.3; and ICH, 0.1 in both cohorts. Patients with cancer at baseline had significantly higher IRs for CRBSIs and thrombosis than non-cancer patients. CVC or HD catheter-related complications were most frequently seen in patients 16 years or younger. The risk of catheter-related complications is highest during the first 90 days of catheter placement in patients with CVCs and HD catheters and in younger patients (≤16 years of age) with HD catheters. Data provided in this study can be applied

  15. [Peripherally inserted central catheter antibiotic therapy for cystic fibrosis patients].

    Science.gov (United States)

    Betegnie, A-L; Cracowski, C; Bedouch, P; Segond, C; Robein-Dobremez, M-J; Pin, I; Allenet, B

    2014-11-01

    Peripherally inserted central catheters (PICC) are more and more used for intravenous antibiotic infusions in cystic fibrosis (CF) patients in the Grenoble area (France). The aim of this study was to assess the use of this technique in this indication. 1. Retrospective evaluation of 102 consecutive PICC insertions over 3years and the incidence of adverse events during the therapy. 2. Prospective evaluation of 12 patient's satisfaction and their nurses over a 3-month period. 3. Comparative analysis of single domiciliary treatment costs using PICC versus peripheral catheter (PC). 102 PICC insertions were attempted in 31 patients. Seven failures and 7 complications occurred during the treatment requiring removal of the PICC, i.e. an overall success rate of 86.2% (88/102). Pain during PICC introduction was 4.2/10 (visual analogical scale). Mean satisfaction levels during therapy were 9.3/10 for patients and 8.7/10 for nurses. Compared with PC, all the patients said that PICC was "more comfortable". Differential costs of treatment with PC and with PICC at home were estimated at 57.15€ and 590.16€ respectively. PICC is an alternative to CP for intravenous antibiotherapy in CF patients, providing better safety and comfort. PICC use should be promoted in this indication. Copyright © 2013 SPLF. Published by Elsevier Masson SAS. All rights reserved.

  16. Experimental measurements and numerical simulation of permittivity and permeability of Teflon in X band

    Directory of Open Access Journals (Sweden)

    Adriano Luiz de Paula

    2011-01-01

    Full Text Available Recognizing the importance of an adequate characterization of radar absorbing materials, and consequently their development, the present study aims to contribute for the establishment and validation of experimental determination and numerical simulation of electromagnetic materials complex permittivity and permeability, using a Teflon® sample. The present paper branches out into two related topics. The first one is concerned about the implementation of a computational modeling to predict the behavior of electromagnetic materials in confined environment by using electromagnetic three-dimensional simulation. The second topic re-examines the Nicolson-Ross-Weir mathematical model to retrieve the constitutive parameters (complex permittivity and permeability of a homogeneous sample (Teflon®, from scattering coefficient measurements. The experimental and simulated results show a good convergence that guarantees the application of the used methodologies for the characterization of different radar absorbing materials samples.

  17. Short-Term Heparin Kinetics during Catheter Ablation of Atrial Fibrillation.

    Science.gov (United States)

    Gabus, Vincent; Rollin, Anne; Maury, Philippe; Forclaz, Andrei; Pascale, Patrizio; Dhutia, Harshil; Bisch, Laurence; Pruvot, Etienne

    2015-10-01

    Percutaneous catheter ablation of atrial fibrillation (CA-AF) is a treatment option for symptomatic drug-refractory atrial fibrillation (AF). CA-AF carries a risk for thromboembolic complications that has been minimized by the use of intraprocedural intravenous unfractionated heparin (UFH). The optimal administration of UFH as well as its kinetics are not well established and need to be precisely determined. A total 102 of consecutive patients suffering from symptomatic drug-refractory AF underwent CA-AF. The mean age was 61 ± 10 years old. After transseptal puncture of the fossa ovalis, weight-adjusted UFH bolus (100 U/kg) was infused. A significant increase in activated clotting time (ACT) was observed from an average value of 100 ± 27 seconds at baseline, to 355 ± 94 seconds at 10 min (T10), to 375 ± 90 seconds at 20 min (T20). Twenty-four patients failed to reach the targeted ACT value of ≥300 seconds at T10 and more than half of these remained with subtherapeutic ACT values at T20. This subset of patients showed similar clinical characteristics and amount of UFH but were more frequently prescribed preprocedural vitamin K1 than the rest of the study population. In a typical intervention setting, UFH displays unexpected slow anticoagulation kinetics in a significant proportion of procedures up to 20 minutes after infusion. These findings support the infusion of UFH before transseptal puncture or any left-sided catheterization with early ACT measurements to identify patients with delayed kinetics. They are in line with recent guidelines to perform CA-AF under therapeutic anticoagulation. © 2015 Wiley Periodicals, Inc.

  18. Metabolic and hemodynamic effects of saline infusion to maintain volemia on temporary abdominal aortic occlusion

    Directory of Open Access Journals (Sweden)

    Fábio Ferreira Amorim

    2002-10-01

    Full Text Available OBJECTIVE: To analyze hemodynamic and metabolic effects of saline solution infusion in the maintenance of blood volume in ischemia-reperfusion syndrome during temporary abdominal aortic occlusion in dogs. METHODS: We studied 20 dogs divided into 2 groups: the ischemia-reperfusion group (IRG, n=10 and the ischemia-reperfusion group with saline solution infusion aiming at maintaining mean pulmonary arterial wedge pressure between 10 and 20 mmHg (IRG-SS, n=10. All animals were anesthetized with sodium thiopental and maintained on spontaneous ventilation. Occlusion of the supraceliac aorta was obtained with inflation of a Fogarty catheter inserted through the femoral artery. After 60 minutes of ischemia, the balloon was deflated, and the animals were observed for another 60 minutes of reperfusion. RESULTS: IRG-SS dogs did not have hemodynamic instability after aortic unclamping, and the mean systemic blood pressure and heart rate were maintained. However, acidosis worsened, which was documented by a greater reduction of arterial pH that occurred especially due to the absence of a respiratory response to metabolic acidosis that was greater with the adoption of this procedure. CONCLUSION: Saline solution infusion to maintain blood volume avoided hemodynamic instability after aortic unclamping. This procedure, however, caused worsening in metabolic acidosis in this experimental model.

  19. Vascular access in neonatology: peripherally inserted central catheter and peripheral venous catheter

    Directory of Open Access Journals (Sweden)

    Marcia Lienemann

    2014-04-01

    The objective of this paper is to present aspects of peripherally inserted central catheter and peripheral venous catheter, highlighting important points in choosing the type of access. For the passage of peripherally inserted central catheter is previously performing specific course necessary, while the primary indication occurs when it is necessary to access the patient's stay for a long period of time. Whereas peripheral venipuncture is the most appropriate in cases of needing an IV line quickly and safely, for the administration of fluids, blood collection, blood transfusion and other.

  20. Emergency coronary angioplasty with stenting using Cordis® diagnostic coronary catheters when there is difficulty in engaging guide catheters and bench evaluation of diagnostic and guide catheters.

    Science.gov (United States)

    Arokiaraj, Mark Christopher

    2018-02-01

    Difficulty in engaging with guide catheters is not uncommon in acute emergencies. We aimed to evaluate the use of Cordis ® INFINITI diagnostic catheters to perform angioplasty in patients in whom the coronaries cannot be engaged using standard guide catheters. In 34 cases of acute coronary syndrome, when difficulty in engagement with two standard guide catheters was encountered with reasonable manipulations, angioplasty was performed using diagnostic catheters. In total, 40 stents were placed by this technique. Pushability and trackability, distal tip flexion and three-point bending tests were performed to evaluate the performance of the guide and diagnostic catheters. Angioplasty was performed easily in a setting where it would have been very difficult to perform. Coronary dissection occurred in one patient, treated by a stent. The stent and dilatation balloons were easily passed through the diagnostic catheters. Pressure tracings were clearly preserved with certain stent delivery systems, and at angioplasty, although there was slightly reduced opacification of the respective artery, the coronary anatomy was sufficiently visualized to perform angioplasty. No periprocedural target lesion complications were seen in any cases. Pushability and trackability tests showed good force transmission along a tortuous path with diagnostic catheters, and balanced force-displacement curves from three-point bending tests and distal tip softness tests. Angioplasty with stenting can be performed safely through 6F Cordis ® infiniti diagnostic catheters when difficulty in engaging guide catheters is encountered. Copyright © 2018 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Intracorporeal knotting of a femoral nerve catheter

    Directory of Open Access Journals (Sweden)

    Ghanem, Mohamed

    2015-01-01

    Full Text Available Peripheral nerve catheters are effective and well-established tools to provide postoperative analgesia to patients undergoing orthopedic surgery. The performance of these techniques is usually considered safe. However, placement of nerve catheters may be associated with a considerable number of side effects and major complications have repeatedly been published. In this work, we report on a patient who underwent total knee replacement with spinal anesthesia and preoperative insertion of femoral and sciatic nerve catheters for postoperative analgesia. During insertion of the femoral catheter, significant resistance was encountered upon retracting the catheter. This occurred due to knotting of the catheter. The catheter had to be removed by operative intervention which has to be considered a major complication. The postoperative course was uneventful. The principles for removal of entrapped peripheral catheters are not well established, may differ from those for neuroaxial catheters, and range from cautious manipulation up to surgical intervention.

  2. Teflon granulomas mimicking cerebellopontine angle tumors following microvascular decompression.

    Science.gov (United States)

    Deep, Nicholas L; Graffeo, Christopher S; Copeland, William R; Link, Michael J; Atkinson, John L; Neff, Brian A; Raghunathan, Aditya; Carlson, Matthew L

    2017-03-01

    To report two patients with a history of microvascular decompression (MVD) for hemifacial spasm who presented with Teflon granulomas (TG) mimicking cerebellopontine angle (CPA) tumors and to perform a systematic review of the English-language literature. Case series at a single tertiary academic referral center and systematic review. Retrospective chart review with analysis of clinical, radiological, and histopathological findings. Systematic review using PubMed, Embase, MEDLINE, and Web of Science databases. Two patients with large skull base TGs mimicking CPA tumors clinically and radiographically were managed at the authors' institution. The first presented 4 years after MVD with asymmetrical sensorineural hearing loss, multiple progressive cranial neuropathies, and brainstem edema due to a growing TG. Reoperation with resection of the granuloma confirmed a foreign-body reaction consisting of multinucleated giant cells containing intracytoplasmic Teflon particles. The second patient presented 11 years after MVD with asymmetrical sensorineural hearing loss and recurrent hemifacial spasm. No growth was noted over 2 years, and the patient has been managed expectantly. Only one prior case of TG after MVD for hemifacial spasm has been reported in the English literature. TG is a rare complication of MVD for hemifacial spasm. The diagnosis should be suspected in patients presenting with a new-onset enhancing mass of the CPA after MVD, even when performed decades earlier. A thorough clinical and surgical history is critical toward establishing an accurate diagnosis to guide management and prevent unnecessary morbidity. Surgical intervention is not required unless progressive neurologic complications ensue. 4 Laryngoscope, 127:715-719, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  3. The feasible study of vasodilators in portal vein targeting infusion for treating portal hypertension

    International Nuclear Information System (INIS)

    Wu Hanping; Liang Huiming; Zheng Chuansheng; Feng Gansheng

    2002-01-01

    Objective: To find out the ideal portal vein tar getting injection routes for portal hypertension treatment. Methods: 28 cirrhotic rat models with portal hypertension induced by CCl 4 were divided into 4 groups: inferior caval vein injection group, portal vein injection group, hepatic artery injection group, spleen injection group. The changes in portal vein pressure (PVP), inferior caval vein pressure (ICVP), mean artery pressure (MAP) and heart rate (HR) were monitored before and after prazosin injection. Results: After intra-portal, intra-hepatic arterial or spleen injection of prazosin, larger decrease in PVP and lesser effects on MAP than intravenous injection had been induced. The effect on HR showed no difference among these four groups. Conclusions: Hepatic artery and spleen prazosin administration have the same advantages on treatment of portal hypertension as those of intra-portal infusion, that is the greater decrease on portal vein pressure, the lesser effects on systemic hemodynamics. Vasodilation drugs for hepatic artery infusion through percutaneous port catheter system by hepatic artery implantation would be an ideal method for portal hypertension treatment

  4. Radiologic placement of Hickman catheters

    International Nuclear Information System (INIS)

    Robertson, L.J.; Mauro, M.A.; Jaques, P.F.

    1988-01-01

    Hickman catheter inserter has previously been predominantly accomplished surgically by means of venous cutdown or percutaneous placement in the operating room. The authors describe their method and results for 55 consecutive percutaneous placements of Hickman catheters in the interventional radiology suite. Complication rates were comparable to those for surgical techniques. Radiologic placement resulted in increased convenience, decreased time and cost of insertion, and super fluoroscopic control of catheter placement and any special manipulations. Modern angiographic materials provide safer access to the subclavian vein than traditional methods. The authors conclude that radiologic placement of Hickman catheters offers significant advantages over traditional surgical placement

  5. Performance of silvered Teflon (trademark) thermal control blankets on spacecraft

    Science.gov (United States)

    Pippin, Gary; Stuckey, Wayne; Hemminger, Carol

    1993-01-01

    Silverized Teflon (Ag/FEP) is a widely used passive thermal control material for space applications. The material has a very low alpha/e ratio (less than 0.1) for low operating temperatures and is fabricated with various FEP thicknesses (as the Teflon thickness increases, the emittance increases). It is low outgassing and, because of its flexibility, can be applied around complex, curved shapes. Ag/FEP has achieved multiyear lifetimes under a variety of exposure conditions. This has been demonstrated by the Long Duration Exposure Facility (LDEF), Solar Max, Spacecraft Charging at High Altitudes (SCATHA), and other flight experiments. Ag/FEP material has been held in place on spacecraft by a variety of methods: mechanical clamping, direct adhesive bonding of tapes and sheets, and by Velcro(TM) tape adhesively bonded to back surfaces. On LDEF, for example, 5-mil blankets held by Velcro(TM) and clamping were used for thermal control over 3- by 4-ft areas on each of 17 trays. Adhesively bonded 2- and 5-mil sheets were used on other LDEF experiments, both for thermal control and as tape to hold other thermal control blankets in place. Performance data over extended time periods are available from a number of flights. The observed effects on optical properties, mechanical properties, and surface chemistry will be summarized in this paper. This leads to a discussion of performance life estimates and other design lessons for Ag/FEP thermal control material.

  6. A prospective randomized trial of Teflon versus polyethylene stents for distal malignant biliary obstruction

    NARCIS (Netherlands)

    van Berkel, A. M.; Boland, C.; Redekop, W. K.; Bergman, J. J.; Groen, A. K.; Tytgat, G. N.; Huibregtse, K.

    1998-01-01

    Clogging of biliary stents continues to be a major clinical problem. Different polymer materials may have different effects on clogging. In vitro studies have shown a direct relation between the frictional coefficient of a polymer and the amount of encrusted material. Teflon appeared to be the best

  7. The effect of ambient ozone and humidity on the performance of nylon and Teflon filters used in ambient air monitoring filter-pack systems

    Science.gov (United States)

    PE Padgett

    2010-01-01

    Nylon and Teflon filter media are frequently used for monitoring ambient air pollutants. These media are subject to many environmental factors that may influence adsorption and retention of particulate and gaseous nitrogenous pollutants. This study evaluated the effects of ozone and humidity on the efficacy of nylon and Teflon filters used in the US dry deposition...

  8. Radiofrequency catheter oblation in atrial flutter

    International Nuclear Information System (INIS)

    Yan Ji; Wang Heping; Xu Jian; Liu Fuyuan; Fan Xizhen; An Chunsheng; Han Xiaoping; Ding Xiaomei; Wang Jiasheng; Gu Tongyuan

    2002-01-01

    Objective: To evaluate the radiofrequency catheter ablation for type I atrial flutter through application of Holo catheter labelling with anatomic imaging localization to ablate the isthmus of IVCTA during complete double-way block. Methods: Eleven cases with type I atrial flutter undergone Holo catheter labelling technique and consecution with conduction time change of coronary venous sinus orifice with-right atrial lower lateral wall pace excitation, were performed with radiofrequency catheter ablation for the isthmus outcoming with complete double-way conduction block. Results: All together 11 cases with 4 of atrial flutter and 7 of sinus rhythm were undergone radiofrequency catheter ablation resulting with double-way conduction block of the isthmus accompanied by prolongation of right atrial conduction time 56.0 ± 2.3 ms and 53.0 ± 4.6 ms respectively. The right atrial excitation appeared to be in clockwise and counter-clockwise of single direction. No recurrence occurred during 3-34 months follow up with only one showing atrial fibrillation. Conclusions: The application of Holo catheter labelling technique with anatomic imaging localization to achieve the double-way conduction block by radiofrequency catheter ablation of TVC-TA isthmus, is a reliable method for treating atrial flutter

  9. The effect of peripherally inserted central catheter (PICC) valve technology on catheter occlusion rates--the 'ELeCTRiC' study.

    Science.gov (United States)

    Johnston, Andrew J; Streater, Carmel T; Noorani, Remy; Crofts, Joanne L; Del Mundo, Aldwin B; Parker, Richard A

    2012-01-01

    Peripherally Inserted Central Catheters (PICCs) are increasingly being used to provide short to medium-term central venous access. The current study was designed to test the hypothesis that PICC valve technology does not influence PICC occlusion rates. Intensive care unit (ICU) patients who required a PICC were randomized to one of three types of dual lumen PICC (open ended non-valved, Groshong valve, PASV valve). PICC occlusions were recorded and managed with a protocol that used urokinase. A total of 102 patients were recruited to the study. The overall risk of occlusion per catheter was 35% (95% CI 26% to 44%). The overall rate of occlusion was 76 occlusions per 1000 catheter days (95% CI 61 to 95). Presence or type of valve did not significantly influence this rate (open-ended non-valved PICC 38% of catheters, 79 occlusions per 1000 catheter days; Groshong 38% of catheters, 60 occlusions per 1000 catheter days; PASV 27% of catheters, 99 occlusions per 1000 catheter days). The dose of urokinase required to treat PICC occlusions did not significantly differ between PICC types. Valved PICCs do not appear to influence PICC occlusion rates.

  10. Hepatic perfusion during hepatic artery infusion chemotherapy: Evaluation with perfusion CT and perfusion scintigraphy

    International Nuclear Information System (INIS)

    Miller, D.L.; Carrasquillo, J.A.; Lutz, R.J.; Chang, A.E.

    1989-01-01

    The standard method for the evaluation of hepatic perfusion during hepatic artery infusion (HAI) chemotherapy is planar hepatic artery perfusion scintigraphy (HAPS). Planar HAPS was performed with 2 mCi of [99mTc] macroaggregated albumin infused at 1 ml/min and compared with single photon emission CT (SPECT) HAPS and with a new study, CT performed during the slow injection of contrast material through the HAI catheter (HAI-CT). Thirteen patients underwent 16 HAI-CT studies, 14 planar HAPS studies, and 9 SPECT HAPS studies. In 13 of 14 studies (93%) HAI-CT and planar HAPS were in complete agreement as to the perfusion pattern of intrahepatic metastases and normal liver. In nine studies where all modalities were performed, the findings identified by HAI-CT and planar HAPS agreed in all cases, whereas the results of two SPECT scans disagreed with the other studies. With respect to perfusion of individual metastases, 14 of 14 HAI-CT studies, 12 of 13 planar HAPS studies, and 9 of 9 SPECT HAPS studies correctly demonstrated the perfusion status of individual lesions as indicated by the pattern of changes in tumor size determined on CT obtained before and after the perfusion studies. Hepatic artery infusion CT was superior for delineation of individual metastases, particularly small lesions, and for the evaluation of nonperfused portions of the liver. Planar HAPS detected extrahepatic perfusion in four patients, and this was not detected by HAI-CT. We conclude that HAI-CT and scintigraphy are complementary techniques. Hepatic artery infusion CT has advantages for the evaluation of intrahepatic perfusion, and planar HAPS is superior to HAI-CT for the detection of extrahepatic perfusion

  11. In vitro analysis of balloon cuffing phenomenon: inherent biophysical properties of catheter material or mechanics of catheter balloon deflation?

    Science.gov (United States)

    Chung, Eric; So, Karina

    2012-06-01

    To investigates the different methods of balloon deflation, types of urinary catheters and exposure to urine media in catheter balloon cuffing. Bardex®, Bard-Lubri-Sil®, Argyle®, Releen® and Biocath® were tested in sterile and E.Coli inoculated urine at 0, 14 and 28 days. Catheter deflation was performed with active deflation; passive deflation; passive auto-deflation; and excision of the balloon inflow channel. Balloon cuffing was assessed objectively by running the deflated balloon over a plate of agar and subjectively by 3 independent observers. Bardex®, Argyle® and Biocath® showed greater degree of catheter balloon cuffing (p deflation was the worst method (p 0.05). Linear regression model analysis confirmed time as the most significant factor. The duration of catheters exposure, different deflation methods and types of catheters tested contributed significantly to catheter balloon cuffing (p < 0.01).

  12. Synthesis of perm-selective membranes by grafting acrylic acid into air-irradiated Teflon-FEP films

    Science.gov (United States)

    Bozzi, Annick; Chapiro, Adolphe

    Grafting acrylic acid into air-irradiated Teflon-FEP films was investigated. Pre-irradiation doses ranged from 0.5 to 10 kGy. Grafting occurred at 45 or 60°C. Homopolymerization inhibitors, ferrous ions or methylene blue, were added to the system. It was found that after completion of the reaction, within 40-100 min, membranes were obtained with very low electric resistivities. The influence of added inhibitors, pre-irradiation dose and grafting temperature was studied. From the results it is concluded that the initiating centers in air-irradiated Teflon-FEP are, on the one hand, peroxides of structure POOP', in which P is a polymeric radical and Pprime; a small fragment, and on the other trapped PO .2 radicals. The latter only react after losing their oxygen. In the presence of polymerization inhibitors, initiation involves a redox process which reduces the overall activation energy.

  13. Synthesis of perm-selective membranes by grafting acrylic acid into air-irradiated Teflon-FEP films

    International Nuclear Information System (INIS)

    Bozzi, Annick; Chapiro, Adolphe

    1988-01-01

    Grafting acrylic acid into air-irradiated Teflon-FEP films was investigated. Pre-irradiation doses ranged from 0.5 to 10 kGy. Grafting occurred at 45 or 60 0 C. Homopolymerization inhibitors, ferrous ions or methylene blue, were added to the system. It was found that after completion of the reaction, within 40-100 min, membranes were obtained with very low electric resistivities. The influence of added inhibitors, pre-irradiation dose and grafting temperature was studied. From the results it is concluded that the initiating centers in air-irradiated Teflon-FEP are, on the one hand, peroxides of structure POOP', in which P is a polymeric radical and P' a small fragment, and on the other hand trapped PO 2 sup(·) radicals. The latter only react after losing their oxygen. In the presence of polymerization inhibitors, initiation involves a redox process which reduces the overall activation energy. (author)

  14. Prevention of catheter-related blood stream infection.

    Science.gov (United States)

    Byrnes, Matthew C; Coopersmith, Craig M

    2007-08-01

    Catheter-related blood stream infections are a morbid complication of central venous catheters. This review will highlight a comprehensive approach demonstrated to prevent catheter-related blood stream infections. Elements of prevention important to inserting a central venous catheter include proper hand hygiene, use of full barrier precautions, appropriate skin preparation with 2% chlorhexidine, and using the subclavian vein as the preferred anatomic site. Rigorous attention needs to be given to dressing care, and there should be daily assessment of the need for central venous catheters, with prompt removal as soon as is practicable. Healthcare workers should be educated routinely on methods to prevent catheter-related blood stream infections. If rates remain higher than benchmark levels despite proper bedside practice, antiseptic or antibiotic-impregnated catheters can also prevent infections effectively. A recent program utilizing these practices in 103 ICUs in Michigan resulted in a 66% decrease in infection rates. There is increasing recognition that a comprehensive strategy to prevent catheter-related blood stream infections can prevent most infections, if not all. This suggests that thousands of infections can potentially be averted if the simple practices outlined herein are followed.

  15. Catheter-directed thrombolytic therapy for thoracic deep vein thrombosis is safe and effective in selected patients with and without cancer

    International Nuclear Information System (INIS)

    Maleux, Geert; Marchal, Pieter; Heye, Sam; Vaninbroukx, Johan; Palmers, Marleen; Verhamme, Peter; Verhaeghe, Raymond

    2010-01-01

    To assess the safety, feasibility and efficacy of catheter-directed thrombolysis for thoracic central venous thrombosis in both cancer and non-cancer patients. A retrospective case series of 68 patients, including 35 with active cancer and 33 without cancer, was analysed. They all received catheter-directed thrombolysis with alteplase or urokinase for symptomatic acute major thoracic vein thrombosis. Substantial clot lysis was obtained in 62 out of 68 patients (91%), the results being 88.6 and 93.8% for cancer and non-cancer patients respectively (P = 0.68). The mean infusion time in patients with and without cancer was 2.11 and 1.84 days respectively (P = 0.3259). Procedure-related complications occurred in two cancer patients (8.6%) and in seven non-cancer patients (21%) (P = 0.18). One cancer patient developed a fatal intracranial bleeding. Additional intervention after successful lysis was performed in cancer (n = 18; 51%) as well as in non-cancer patients (n = 29; 88%). Catheter-directed thrombolysis is a feasible and highly effective interventional procedure with an acceptable safety profile in selected patients with and without cancer for the treatment of symptomatic thoracic central venous thrombosis. In most cases, additional endovascular or surgical procedures are required to restore and maintain vessel patency after successful thrombolysis. (orig.)

  16. Role of Catheter-directed Thrombolysis in Management of Iliofemoral Deep Venous Thrombosis.

    Science.gov (United States)

    Chen, James X; Sudheendra, Deepak; Stavropoulos, S William; Nadolski, Gregory J

    2016-01-01

    The treatment for iliofemoral deep venous thrombosis (DVT) is challenging, as the use of anticoagulation alone can be insufficient for restoring venous patency and thus lead to prolongation of acute symptoms and an increased risk of chronic complications, including venous insufficiency and postthrombotic syndrome (PTS). In these cases, earlier and more complete thrombus removal can ameliorate acute symptoms and reduce long-term sequelae. Endovascular therapies involving the use of pharmacologic, mechanical, and combined pharmacomechanical modalities have been developed to achieve these goals. The most frequently used of these techniques, catheter-directed thrombolysis (CDT), involves the infusion of a thrombolytic agent through a multiple-side-hole catheter placed within the thrombosed vein to achieve high local doses and thereby break down the clot while minimizing systemic thrombolytic agent exposure. Randomized controlled trial results have indicated decreased PTS rates and improved venous patency rates in patients treated with CDT compared with these rates in patients treated with anticoagulation. The use of newer pharmacomechanical techniques, as compared with conventional CDT, reduces procedural times and thrombolytic agent doses and is the subject of ongoing investigations. Endovascular thrombus removal techniques offer a means to improve venous valvular function and decrease the risk of debilitating long-term complications such as PTS and are a promising option for treating patients with iliofemoral DVT. (©)RSNA, 2016.

  17. Usefulness of gram staining of blood collected from total parenteral nutrition catheter for rapid diagnosis of catheter-related sepsis.

    Science.gov (United States)

    Moonens, F; el Alami, S; Van Gossum, A; Struelens, M J; Serruys, E

    1994-01-01

    The accuracy of Gram staining of blood drawn from catheters used to administer total parenteral nutrition was compared with paired quantitative blood cultures for the diagnosis of catheter-related sepsis. Gram staining was positive in 11 of 18 episodes of catheter-related sepsis documented by quantitative culture (sensitivity, 61%) but in none of the 5 episodes of fever unrelated to catheter infection. Thus, this procedure enabled the rapid presumptive diagnosis and guidance of antimicrobial therapy for total parenteral nutrition catheter sepsis, with a positive predictive value of 100% and a negative predictive value of 42%. PMID:7521359

  18. Characteristics of high-purity Teflon vial for 14C measurement in old tree rings

    International Nuclear Information System (INIS)

    Sakurai, H.; Saswaki, Y.; Matsumoto, T.; Aoki, T.; Kato, W.; Gandou, T.; Gunji, S.; Tokanai, F.

    2003-01-01

    14 C concentration in single-year tree rings of an old cedar of ca. 2500 years ago is measured to investigate the 11-yr periodicity of solar activity. Our highly accurate 14 C measuring system is composed of a benzene synthesizer capable of producing a large quantity (10 g) of benzene and a Quantulus 1220 TM liquid scintillation counting system. The accuracy is less than 0.2% for measurements of 14 C concentration. The benzene sample is contained in a high-purity Teflon/copper-counting vial (20 ml) manufactured by Wallac Oy Company. We found a vial with an irregular copper cap for the measurements of 11 tree rings. The behavior of the vial with the irregular cap was investigated. The Teflon sheet inside the cap plays an important role in achieving stable measurement. The rate of volatilization of the benzene was less than 0.35 mg/day for vials with ordinary caps. This results in the volatilization rate of 0.003% for 10.5 g of benzene and hence guarantees measurement at an accuracy of 0.2% for 70 days

  19. [Peripheral intravenous catheter-related phlebitis].

    Science.gov (United States)

    van der Sar-van der Brugge, Simone; Posthuma, E F M Ward

    2011-01-01

    Phlebitis is a very common complication of the use of intravenous catheters. Two patients with an i.v. catheter complicated by thrombophlebitis are described. Patient A was immunocompromised due to chronic lymphatic leukaemia and developed septic thrombophlebitis with positive blood cultures for S. Aureus. Patient B was being treated with flucloxacillin because of an S. Aureus infection and developed chemical phlebitis. Septic phlebitis is rare, but potentially serious. Chemical or mechanical types of thrombophlebitis are usually less severe, but happen very frequently. Risk factors include: female sex, previous episode of phlebitis, insertion at (ventral) forearm, emergency placement and administration of antibiotics. Until recently, routine replacement of peripheral intravenous catheters after 72-96 h was recommended, but randomised controlled trials have not shown any benefit of this routine. A recent Cochrane Review recommends replacement of peripheral intravenous catheters when clinically indicated only.

  20. Selected laboratory evaluations of the whole-water sample-splitting capabilities of a prototype fourteen-liter Teflon churn splitter

    Science.gov (United States)

    Horowitz, A.J.; Smith, J.J.; Elrick, K.A.

    2001-01-01

    A prototype 14-L Teflon? churn splitter was evaluated for whole-water sample-splitting capabilities over a range of sediment concentratons and grain sizes as well as for potential chemical contamination from both organic and inorganic constituents. These evaluations represent a 'best-case' scenario because they were performed in the controlled environment of a laboratory, and used monomineralic silica sand slurries of known concentration made up in deionized water. Further, all splitting was performed by a single operator, and all the requisite concentration analyses were performed by a single laboratory. The prototype Teflon? churn splitter did not appear to supply significant concentrations of either organic or inorganic contaminants at current U.S. Geological Survey (USGS) National Water Quality Laboratory detection and reporting limits when test samples were prepared using current USGS protocols. As with the polyethylene equivalent of the prototype Teflon? churn, the maximum usable whole-water suspended sediment concentration for the prototype churn appears to lie between 1,000 and 10,000 milligrams per liter (mg/L). Further, the maximum grain-size limit appears to lie between 125- and 250-microns (m). Tests to determine the efficacy of the valve baffle indicate that it must be retained to facilitate representative whole-water subsampling.

  1. Teflon/SiO₂ Bilayer Passivation for Improving the Electrical Reliability of Oxide TFTs Fabricated Using a New Two-Photomask Self-Alignment Process.

    Science.gov (United States)

    Fan, Ching-Lin; Shang, Ming-Chi; Li, Bo-Jyun; Lin, Yu-Zuo; Wang, Shea-Jue; Lee, Win-Der; Hung, Bohr-Ran

    2015-04-13

    This study proposes a two-photomask process for fabricating amorphous indium-gallium-zinc oxide (a-IGZO) thin-film transistors (TFTs) that exhibit a self-aligned structure. The fabricated TFTs, which lack etching-stop (ES) layers, have undamaged a-IGZO active layers that facilitate superior performance. In addition, we demonstrate a bilayer passivation method that uses a polytetrafluoroethylene (Teflon) and SiO₂ combination layer for improving the electrical reliability of the fabricated TFTs. Teflon was deposited as a buffer layer through thermal evaporation. The Teflon layer exhibited favorable compatibility with the underlying IGZO channel layer and effectively protected the a-IGZO TFTs from plasma damage during SiO₂ deposition, resulting in a negligible initial performance drop in the a-IGZO TFTs. Compared with passivation-free a-IGZO TFTs, passivated TFTs exhibited superior stability even after 168 h of aging under ambient air at 95% relative humidity.

  2. Fast Surface Temperature Measurement of Teflon Propellant in Pulsed Ablative Discharges Using HgCdTe Photovoltaic Cells (PREPRINT)

    National Research Council Canada - National Science Library

    Antonsen, Erik L; Burton, Rodney L; Reed, Garrett A; Spanjers, Gregory G

    2006-01-01

    ... ablative discharge with Teflon(TradeMark) as the ablated material. Analysis is used to derive a governing equation for detector output voltage for materials with wavelength dependent emissivity...

  3. 21 CFR 868.5120 - Anesthesia conduction catheter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anesthesia conduction catheter. 868.5120 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5120 Anesthesia conduction catheter. (a) Identification. An anesthesia conduction catheter is a flexible tubular device used to inject...

  4. Agile and Bright Intracardiac Catheters

    NARCIS (Netherlands)

    M. Pekař (Martin)

    2017-01-01

    markdownabstractIntracardiac imaging catheters represent unique instruments to diagnose and treat a diseased heart. While there are imminent advances in medical innovation, many of the commercially available imaging catheters are outdated. Some of them have been designed more than 20 years and

  5. Continuous paravertebral infusion of ropivacaine with or without fentanyl for pain relief in unilateral multiple fractured ribs

    Directory of Open Access Journals (Sweden)

    Medha Mohta

    2013-01-01

    Full Text Available Background: Continuous thoracic paravertebral block (TPVB provides effective analgesia for unilateral multiple fractured ribs (MFR. However, prolonged infusion of local anaesthetic (LA in high doses can predispose to risk of LA toxicity, which may be reduced by using safer drugs or drug combinations. This study was conducted to assess efficacy and safety of paravertebral infusion of ropivacaine and adrenaline with or without fentanyl to provide analgesia to patients with unilateral MFR. Methods: Thirty adults, having ≥3 unilateral MFR, with no significant trauma outside chest wall, were studied. All received bolus of 0.5% ropivacaine 0.3 ml/kg through paravertebral catheter, followed by either 0.1-0.2 ml/kg/hr infusion of ropivacaine 0.375% with adrenaline 5 μg/ml in group RA or ropivacaine 0.2% with adrenaline 5 μg/ml and fentanyl 2 μg/ml in group RAF. Rescue analgesia was provided by IV morphine. Results: Statistical analysis was performed using unpaired Student t-test, Chi-square test and repeated measures ANOVA. After TPVB, VAS scores, respiratory rate and PEFR improved in both groups with no significant inter-group differences. Duration of ropivacaine infusion, morphine requirements, length of ICU and hospital stay, incidence of pulmonary complications and opioid-related side-effects were similar in both groups. Ropivacaine requirement was higher in group RA than group RAF. No patient showed signs of LA toxicity. Conclusion: Continuous paravertebral infusion of ropivacaine 0.375% with adrenaline 5 μg/ml at 0.1-0.2 ml/kg/hr provided effective and safe analgesia to patients with unilateral MFR. Addition of fentanyl 2 μg/ml allowed reduction of ropivacaine concentration to 0.2% without decreasing efficacy or increasing opioid-related side-effects.

  6. 21 CFR 876.5030 - Continent ileostomy catheter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Continent ileostomy catheter. 876.5030 Section 876...) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5030 Continent ileostomy catheter. (a) Identification. A continent ileostomy catheter is a flexible tubular device used as a form...

  7. FAQs about Catheter-Associated Urinary Tract Infection

    Science.gov (United States)

    ... do so. o Avoid disconnecting the catheter and drain tube. This helps to pre - vent germs from getting into the catheter tube. o The catheter is secured to the leg to prevent pulling on the ... regularly. The drainage spout should not touch any - thing while emptying ...

  8. The dangers of long-term catheter drainage.

    Science.gov (United States)

    Lowthian, P

    There are many dangers associated with long-term urinary bladder drainage by catheter. For various reasons, the choice of catheter is important, and its initial insertion can be particularly hazardous. All catheterizations should, however, be safer when there is some urine (or other fluid) in the bladder. The appropriate choice of drainage system attached to the catheter can delay bacterial invasion of the bladder. Great care is needed to prevent blockage of the system, particularly when bacteriuria is present. Recent evidence indicates that some bacteria encourage the development of encrustations, so that, in some circumstances, catheters may become blocked within 24 hours. This, together with other considerations, strongly suggests that indwelling catheters should be changed at intervals of not more than 5 days. The practical implications of this are considered, as are the benefits that may accrue. Accidental catheter traction is another danger, and some possible methods of avoiding this are discussed. Finally, the need for a new kind of drainage-bag support is highlighted.

  9. Biological safety evaluation of the modified urinary catheter

    Energy Technology Data Exchange (ETDEWEB)

    Kowalczuk, Dorota, E-mail: dorota.kowalczuk@umlub.pl [Department of Medicinal Chemistry, Medical University of Lublin, Jaczewskiego 4, 20-090 Lublin (Poland); Przekora, Agata; Ginalska, Grazyna [Department of Biochemistry and Biotechnology, Medical University of Lublin, Chodzki 1, 20-093 Lublin (Poland)

    2015-04-01

    The purpose of this study was to evaluate in vitro safety of the novel tosufloxacin (TOS)-treated catheters with the prolonged antimicrobial activity. The test samples of silicone latex catheter were prepared by the immobilization of TOS on chitosan (CHIT)-coated catheter by means of covalent bonds and non-covalent interactions. Each step of the modification process of catheter surface was observed using ATR–Fourier transform infrared spectroscopy. In vitro cytotoxicity of the modified and unmodified catheters was assessed by direct and indirect tests in accordance with ISO standards using green monkey kidney (GMK) cell line. The MTT, lactate dehydrogenase activity (LDH), WST-8, Sulforhodamine B (SRB) test results and microscopic observation clearly indicated that unmodified silicone latex catheters decrease cell metabolic activity, act as a cytotoxic agent causing cell lysis and induce cell death through necrotic or apoptotic process. We suggest that chitosan coat with TOS immobilized limits leaching of harmful agents from silicone latex material, which significantly enhances survivability of GMK cells and therefore is quite a good protection against the cytotoxic effect of this material. - Highlights: • Characterization of the novel antimicrobial urinary catheters • Monitoring of the catheter modification by FTIR analysis • Confirmation of high cytotoxicity of latex-based catheter used in urological practice • Chitosan-coated and tosufloxacin-treated catheter is less toxic than the untreated one. • The proposed surface modification protects cells against latex-induced death.

  10. Reducing catheter-related thrombosis using a risk reduction tool centered on catheter to vessel ratio.

    Science.gov (United States)

    Spencer, Timothy R; Mahoney, Keegan J

    2017-11-01

    In vascular access practices, the internal vessel size is considered important, and a catheter to vessel ratio (CVR) is recommended to assist clinicians in selecting the most appropriate-sized device for the vessel. In 2016, new practice recommendations stated that the CVR can increase from 33 to 45% of the vessels diameter. There has been evidence on larger diameter catheters and increased thrombosis risk in recent literature, while insufficient information established on what relationship to vessel size is appropriate for any intra-vascular device. Earlier references to clinical standards and guidelines did not clearly address vessel size in relation to the area consumed or external catheter diameter. The aim of this manuscript is to present catheter-related thrombosis evidence and develop a standardized process of ultrasound-guided vessel assessment, integrating CVR, Virchow's triad phenomenon and vessel health and preservation strategies, empowering an evidence-based approach to device placement. Through review, calculation and assessment on the areas of the 33 and 45% rule, a preliminary clinical tool was developed to assist clinicians make cognizant decisions when placing intravascular devices relating to target vessel size, focusing on potential reduction in catheter-related thrombosis. Increasing the understanding and utilization of CVRs will lead to a safer, more consistent approach to device placement, with potential thrombosis reduction strategies. The future of evidence-based data relies on the clinician to capture accurate vessel measurements and device-related outcomes. This will lead to a more dependable data pool, driving the relationship of catheter-related thrombosis and vascular assessment.

  11. Effects of gas–wall partitioning in Teflon tubing and instrumentation on time-resolved measurements of gas-phase organic compounds

    Directory of Open Access Journals (Sweden)

    D. Pagonis

    2017-12-01

    Full Text Available Recent studies have demonstrated that organic compounds can partition from the gas phase to the walls in Teflon environmental chambers and that the process can be modeled as absorptive partitioning. Here these studies were extended to investigate gas–wall partitioning of organic compounds in Teflon tubing and inside a proton-transfer-reaction mass spectrometer (PTR-MS used to monitor compound concentrations. Rapid partitioning of C8–C14 2-ketones and C11–C16 1-alkenes was observed for compounds with saturation concentrations (c∗ in the range of 3 × 104 to 1 × 107 µg m−3, causing delays in instrument response to step-function changes in the concentration of compounds being measured. These delays vary proportionally with tubing length and diameter and inversely with flow rate and c∗. The gas–wall partitioning process that occurs in tubing is similar to what occurs in a gas chromatography column, and the measured delay times (analogous to retention times were accurately described using a linear chromatography model where the walls were treated as an equivalent absorbing mass that is consistent with values determined for Teflon environmental chambers. The effect of PTR-MS surfaces on delay times was also quantified and incorporated into the model. The model predicts delays of an hour or more for semivolatile compounds measured under commonly employed conditions. These results and the model can enable better quantitative design of sampling systems, in particular when fast response is needed, such as for rapid transients, aircraft, or eddy covariance measurements. They may also allow estimation of c∗ values for unidentified organic compounds detected by mass spectrometry and could be employed to introduce differences in time series of compounds for use with factor analysis methods. Best practices are suggested for sampling organic compounds through Teflon tubing.

  12. Effects of gas-wall partitioning in Teflon tubing and instrumentation on time-resolved measurements of gas-phase organic compounds

    Science.gov (United States)

    Pagonis, Demetrios; Krechmer, Jordan E.; de Gouw, Joost; Jimenez, Jose L.; Ziemann, Paul J.

    2017-12-01

    Recent studies have demonstrated that organic compounds can partition from the gas phase to the walls in Teflon environmental chambers and that the process can be modeled as absorptive partitioning. Here these studies were extended to investigate gas-wall partitioning of organic compounds in Teflon tubing and inside a proton-transfer-reaction mass spectrometer (PTR-MS) used to monitor compound concentrations. Rapid partitioning of C8-C14 2-ketones and C11-C16 1-alkenes was observed for compounds with saturation concentrations (c∗) in the range of 3 × 104 to 1 × 107 µg m-3, causing delays in instrument response to step-function changes in the concentration of compounds being measured. These delays vary proportionally with tubing length and diameter and inversely with flow rate and c∗. The gas-wall partitioning process that occurs in tubing is similar to what occurs in a gas chromatography column, and the measured delay times (analogous to retention times) were accurately described using a linear chromatography model where the walls were treated as an equivalent absorbing mass that is consistent with values determined for Teflon environmental chambers. The effect of PTR-MS surfaces on delay times was also quantified and incorporated into the model. The model predicts delays of an hour or more for semivolatile compounds measured under commonly employed conditions. These results and the model can enable better quantitative design of sampling systems, in particular when fast response is needed, such as for rapid transients, aircraft, or eddy covariance measurements. They may also allow estimation of c∗ values for unidentified organic compounds detected by mass spectrometry and could be employed to introduce differences in time series of compounds for use with factor analysis methods. Best practices are suggested for sampling organic compounds through Teflon tubing.

  13. Infusion volume control and calculation using metronome and drop counter based intravenous infusion therapy helper.

    Science.gov (United States)

    Park, Kyungnam; Lee, Jangyoung; Kim, Soo-Young; Kim, Jinwoo; Kim, Insoo; Choi, Seung Pill; Jeong, Sikyung; Hong, Sungyoup

    2013-06-01

    This study assessed the method of fluid infusion control using an IntraVenous Infusion Controller (IVIC). Four methods of infusion control (dial flow controller, IV set without correction, IV set with correction and IVIC correction) were used to measure the volume of each technique at two infusion rates. The infused fluid volume with a dial flow controller was significantly larger than other methods. The infused fluid volume was significantly smaller with an IV set without correction over time. Regarding the concordance correlation coefficient (CCC) of infused fluid volume in relation to a target volume, IVIC correction was shown to have the highest level of agreement. The flow rate measured in check mode showed a good agreement with the volume of collected fluid after passing through the IV system. Thus, an IVIC could assist in providing an accurate infusion control. © 2013 Wiley Publishing Asia Pty Ltd.

  14. Adsorption of IgG onto hydrophobic teflon. Differences between the F(ab) and F(c) domains

    NARCIS (Netherlands)

    Vermeer, AWP; Giacomelli, CE; Norde, W

    2001-01-01

    The effect of differences in the degree of hydrophobicity of protein patches/fragments on the adsorption behaviour of the protein is investigated. The adsorption isotherm of a monoclonal mouse anti-human immunoglobulin G (isotype 2b) onto hydrophobic Teflon particles is measured using a depletion

  15. Paravertebral block catheter breakage by electrocautery during thoracic surgery.

    Science.gov (United States)

    Saeki, Noboru; Sugimoto, Yuki; Mori, Yoko; Kato, Takahiro; Miyoshi, Hirotsugu; Nakamura, Ryuji; Koga, Tomomichi

    2017-06-01

    Advantages of thoracic paravertebral analgesia (TPA) include placement of the catheter closer to the surgical field; however, the catheter can become damaged during the operation. We experienced a case of intraoperative TPA catheter breakage that prompted us to perform an experiment to investigate possible causes. A 50-year-old male underwent a thoracoscopic lower lobectomy under general anesthesia with TPA via an intercostal approach. Following surgery, it was discovered that the catheter had become occluded, as well as cut and fused, so we reopened the incision and removed the residual catheter. From that experience, we performed an experiment to examine electrocautery-induced damage in normal (Portex™, Smith's Medical), radiopaque (Perifix SoftTip™, BBraun), and reinforced (Perifix FX™, BBraun) epidural catheters (n = 8 each). Chicken meat was penetrated by each catheter and then cut by electrocautery. In the normal group, breakage occurred in 8 and occlusion in 6 of the catheters, and in the radiopaque group breakage occurred in 8 and occlusion in 7. In contrast, breakage occurred in only 3 and occlusion in none in the reinforced group, with the 5 without breakage remaining connected only by the spring coil. Furthermore, in 7 of the reinforced catheters, electric arc-induced thermal damage was observed at the tip of the catheter. A TPA catheter for thoracic surgery should be inserted via the median approach, or it should be inserted after surgery to avoid catheter damage during surgery.

  16. Spinal canal extension of hyperalimentation catheter without neurologic sequela

    International Nuclear Information System (INIS)

    Glasier, M.; Arkansas Children's Hospital, Little Rock; Hassell, D.R.

    1989-01-01

    An attempt at placement of a left femoral vein hyperalimentation catheter resulted in entrance of the catheter into the spinal canal. Catheter location was documented by injections of nonionic contrast material into the catheter without neurologic sequellae. (orig.)

  17. Teflon/SiO2 Bilayer Passivation for Improving the Electrical Reliability of Oxide TFTs Fabricated Using a New Two-Photomask Self-Alignment Process

    Science.gov (United States)

    Fan, Ching-Lin; Shang, Ming-Chi; Li, Bo-Jyun; Lin, Yu-Zuo; Wang, Shea-Jue; Lee, Win-Der; Hung, Bohr-Ran

    2015-01-01

    This study proposes a two-photomask process for fabricating amorphous indium–gallium–zinc oxide (a-IGZO) thin-film transistors (TFTs) that exhibit a self-aligned structure. The fabricated TFTs, which lack etching-stop (ES) layers, have undamaged a-IGZO active layers that facilitate superior performance. In addition, we demonstrate a bilayer passivation method that uses a polytetrafluoroethylene (Teflon) and SiO2 combination layer for improving the electrical reliability of the fabricated TFTs. Teflon was deposited as a buffer layer through thermal evaporation. The Teflon layer exhibited favorable compatibility with the underlying IGZO channel layer and effectively protected the a-IGZO TFTs from plasma damage during SiO2 deposition, resulting in a negligible initial performance drop in the a-IGZO TFTs. Compared with passivation-free a-IGZO TFTs, passivated TFTs exhibited superior stability even after 168 h of aging under ambient air at 95% relative humidity. PMID:28788026

  18. Teflon/SiO2 Bilayer Passivation for Improving the Electrical Reliability of Oxide TFTs Fabricated Using a New Two-Photomask Self-Alignment Process

    Directory of Open Access Journals (Sweden)

    Ching-Lin Fan

    2015-04-01

    Full Text Available This study proposes a two-photomask process for fabricating amorphous indium–gallium–zinc oxide (a-IGZO thin-film transistors (TFTs that exhibit a self-aligned structure. The fabricated TFTs, which lack etching-stop (ES layers, have undamaged a-IGZO active layers that facilitate superior performance. In addition, we demonstrate a bilayer passivation method that uses a polytetrafluoroethylene (Teflon and SiO2 combination layer for improving the electrical reliability of the fabricated TFTs. Teflon was deposited as a buffer layer through thermal evaporation. The Teflon layer exhibited favorable compatibility with the underlying IGZO channel layer and effectively protected the a-IGZO TFTs from plasma damage during SiO2 deposition, resulting in a negligible initial performance drop in the a-IGZO TFTs. Compared with passivation-free a-IGZO TFTs, passivated TFTs exhibited superior stability even after 168 h of aging under ambient air at 95% relative humidity.

  19. Outpatient unicompartment knee arthroplasty with indwelling femoral nerve catheter.

    Science.gov (United States)

    Dervin, Geoffrey F; Madden, Susan M; Crawford-Newton, Barbara A; Lane, Alan T; Evans, Holly C

    2012-06-01

    Contemporary multimodal anesthesia regimens allow the performance of unicompartment knee arthroplasty (UKA) on an outpatient basis. Our initial pilot experience is presented using a continuous femoral nerve block as an adjunct for 24 patients classified as American Society of Anesthesiology class 1 (14 men, 10 women; median age, 56 years; range, 46-72 years). After minimally invasive UKA, patients documented their pain and oral medication use while at home for the first 5 days. Adverse events, medication adverse effects, and the amount of infused ropivacaine were recorded. Median pain scores for the first 3 days were 1, 2, and 2 (at rest) and 4, 5, and 3 (during physical therapy). Eighteen patients (75%) required less than 4 mg oral hydromorphone/d. Of the 18, 10 (42%) did not require supplemental oral opioids. The median catheter use was 3 days. Our results suggest that with careful patient selection and adequate teaching, continuous femoral nerve blocks may be used as part of a multimodal pain regimen to assist the delivery of outpatient UKA with high patient satisfaction. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. Study of the conductivity induced by radiation in teflon irradiated by X-ray

    International Nuclear Information System (INIS)

    Faria, R.M.

    1980-01-01

    It's measured the X-ray induced currents in teflon FEP which show the following features: a) At the beginning the current increases and reaches a maximum at about 10s, b) It decays slowly during 30 minutes, when a steady state is reached the delayed conductivity was also measured. The sample were 25 μm thick and the irradiated area was 12,5 cm 2 ; the applied field was of the order of 10 4 V/cm and the dose rate of order of 10 2 R/S. It was observed that a new measurement of the induced conductivity does not duplicate the first one, but after a few hours it comes back to the original one. In order to show that the increase and the decrease of the current is not caused by an electric field effect we realized a measurement where we polled the sample intermitently while it was irradiated. The current thus obtained had about the same values of the first measurement, when the voltage was applied all the time during the measurement. The absorption current of a teflon sample which shows after some days the effect of its variation due the variation of the ambiental temperature are measured. (Author) [pt

  1. Repositioning of malpositioned or flipped central venous catheters

    Energy Technology Data Exchange (ETDEWEB)

    Thalhammer, A.; Jacobi, V.; Balzer, J.; Vogl, T.J. [Institute for Diagnostic and Interventional Radiology, Central Radiology Clinic, J.W. Goethe University, Frankfurt am Main (Germany)

    2002-03-01

    Primary misplaced or secondary flipped implanted catheters are located mostly in the right jugular vein. We demonstrate an effective method to replace fix implanted catheters such as Ports, Grochomg or Hickman catheters. Using a femoral venous approach, replacement into the superior vena cava can easily be done with a Sidewinder 1 catheter which is hooked over the misplaced central venous approach. In all our patients the method was successful. The repositioning technique described is simple, fast and has low costs. We can keep sterile conditions and do not need to solve the catheters' fixation. (orig.)

  2. Albumin infusion after reperfusion prevents gut ischemia-reperfusion-induced gut-associated lymphoid tissue atrophy.

    Science.gov (United States)

    Ikezawa, Fumie; Fukatsu, Kazuhiko; Moriya, Tomoyuki; Maeshima, Yoshinori; Okamoto, Koichi; Hara, Etsuko; Hiraide, Hoshio; Compher, Charlene W

    2006-01-01

    Our recent study clarified that gut ischemia-reperfusion (I/R) causes gut-associated lymphoid tissue (GALT) mass atrophy, a possible mechanism for increased morbidity of infectious complications after severe surgical insults. Because albumin administration reportedly reduces hemorrhagic shock-induced lung injury, we hypothesized that albumin treatment prevents GALT atrophy due to gut I/R. Male mice (n = 37) were randomized to albumin, normal saline, and sham groups. All groups underwent jugular vein catheter insertion. The albumin and normal saline groups underwent 75-minute occlusion of the superior mesenteric artery. During gut ischemia, all mice received normal saline infusions at 1.0 mL/h. The albumin group was given 5% bovine serum albumin in normal saline at 1.0 mL/h for 60 minutes after reperfusion, whereas the normal saline group received 0.9% sodium chloride at 1.0 mL/h. The sham group underwent laparotomy only. Mice were killed on day 1 or 7, and the entire small intestine was harvested. GALT lymphocytes were isolated and counted. Their phenotypes (alphabetaTCR, gammadeltaTCR, CD4, CD8, B220) were determined by flow cytometry. On day 1, the gut I/R groups showed significantly lower total lymphocyte and B cell numbers in Peyer's patches and the lamina propria than the sham group. However, the albumin infusion partially but significantly restored these cell numbers. On day 7, there were no significant differences in any of the parameters measured among the 3 groups. Albumin infusion after a gut ischemic insult may maintain gut immunity by preventing GALT atrophy.

  3. CATHETER DURATION AND THE RISK OF SEPSIS IN PREMATURE BABIES WITH UMBILICAL VEIN CATHETERS

    Directory of Open Access Journals (Sweden)

    Hartojo Hartojo

    2012-01-01

    Full Text Available Umbilical catheters are frequently required in the management of severely ill premature babies. The risk of complications may increase with duration of UVC use. Objective: To determine whether the risk of central line-associated bloodstream infections (CLA-BSIs and sepsis remained constant over the duration of umbilical vein catheters (UVCs in high-risk premature neonates. Methods:retrospective analysis. The data were collected from the medical record of high risk premature neonates who had a UVC placed in neonatal care unit of Husada Utama Hospital between April 1st 2008 to April 30th 2011 with purposive sampling. Catheter duration was observed before and after 14 days on placement. Blood and UVC culture was performed to establish the risk of CLA-BSIs and sepsis. Chi-square and logistic regression analysis were performed in the laboratorium data. Result: A total 44 high risk premature babies with UVCs were enrolled (sepsis group: n = 23 and non sepsis group: n = 21. Baseline demographics were similar between the groups. 15 babies in sepsis group have UVCs duration > 14 days, and 8 babies have UVCs 14 days show blood culture performance in 11 babies with positive evidence, UVCs culture performance is negative in 18 babies (p = 0.456. Burkholderia cepacia and Klebsiella pneumonia mostly appeared in blood culture performance. 25% of UVC culture performance shows Pseudomonas aeroginosa. Conclusions: The catheter duration have no significant difference in risk of sepsis in premature babies with Umbilical Vein Catheters.

  4. Obstruction of peritoneal dialysis catheter is associated with catheter type and independent of omentectomy: A comparative data analysis from a transplant surgical and a pediatric surgical department.

    Science.gov (United States)

    Radtke, Josephine; Schild, Raphael; Reismann, Marc; Ridwelski, Robert-Richard; Kempf, Caroline; Nashan, Bjoern; Rothe, Karin; Koch, Martina

    2018-04-01

    Peritoneal dialysis (PD) catheter occlusion is a common complication with up to 36% of catheter obstructions described in the literature. We present a comparison of complications and outcome after implantation of PD catheters in a transplant surgical and a pediatric surgical department. We retrospectively analyzed 154 PD catheters, which were implanted during 2009-2015 by transplant surgeons (TS, University Medical Center Hamburg-Eppendorf, Germany, n=85 catheters) and pediatric surgeons (PS, Charité University Medicine Berlin, Germany, n=69 catheters) in 122 children (median (range) age 3.0 (0.01-17.1) years) for acute (n=65) or chronic (n=89) renal failure. All catheters were one-cuffed or double-cuffed curled catheters, except that straight catheters were implanted into smaller children (n=19) by TS in Hamburg. Patient characteristics and operation technique did not differ between the departments. Peritonitis was the most common complication (33 catheters, 21.4%). Leakage (n=18 catheters, 11.7%) occurred more often in children weighing <10kg (p<0.001). The incidence of obstruction and dysfunction was significantly higher in catheters used in PS than catheters used in TS (30.4% vs. 11.8%, p=0.004). Omentectomy did not reduce the incidence of catheter obstruction (p=1.0). Perforation at the catheter tips was larger and appeared to be rougher in catheters used in PS than the catheters in TS. The type of catheter and presumably the type of perforation at the catheter tip may influence the incidence of peritoneal dialysis catheter obstruction. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Yttrium-90 Resin Microsphere Radioembolization Using an Antireflux Catheter: An Alternative to Traditional Coil Embolization for Nontarget Protection

    International Nuclear Information System (INIS)

    Morshedi, Maud M.; Bauman, Michael; Rose, Steven C.; Kikolski, Steven G.

    2015-01-01

    PurposeSerious complications can result from nontarget embolization during yttrium-90 (Y-90) transarterial radioembolization. Hepatoenteric artery coil embolization has been traditionally performed to prevent nontarget radioembolization. The U.S. Food and Drug Administration–approved Surefire Infusion System (SIS) catheter, designed to prevent reflux, is an alternative to coils. The hypothesis that quantifiable SIS procedural parameters are comparable to coil embolization was tested.MethodsFourteen patients aged 36–79 years with colorectal, neuroendocrine, hepatocellular, and other predominantly bilobar hepatic tumors who underwent resin microsphere Y-90 radioembolization using only the SIS catheter (n = 7) versus only detachable coils (n = 7) for nontarget protection were reviewed retrospectively. Procedure time, fluoroscopy time, contrast dose, radiation dose, and cost were evaluated.ResultsMultivariate analysis identified significant cohort differences in the procedural parameters evaluated (F(10, 3) = 10.39, p = 0.04). Between-group comparisons of the pretreatment planning procedure in the SIS catheter group compared to the coil embolization group demonstrated a significant reduction in procedure time (102.6 vs. 192.1 min, respectively, p = 0.0004), fluoroscopy time (14.3 vs. 49.7 min, respectively, p = 0.0016), and contrast material dose (mean dose of 174.3 vs. 265.0 mL, respectively, p = 0.0098). Procedural parameters were not significantly different between the two groups during subsequent dose delivery procedures. Overall cost of combined first-time radioembolization procedures was significantly less in the SIS group ($4252) compared to retrievable coil embolization ($11,123; p = 0.001).ConclusionThe SIS catheter results in a reduction in procedure time, fluoroscopy time, and contrast material dose and may be an attractive cost-effective alternative to detachable coil embolization for prevention of nontarget radioembolization

  6. Yttrium-90 Resin Microsphere Radioembolization Using an Antireflux Catheter: An Alternative to Traditional Coil Embolization for Nontarget Protection

    Energy Technology Data Exchange (ETDEWEB)

    Morshedi, Maud M., E-mail: maud.morshedi@my.rfums.org; Bauman, Michael, E-mail: mbauman@ucsd.edu; Rose, Steven C., E-mail: scrose@ucsd.edu; Kikolski, Steven G., E-mail: skikolski@gmail.com [University of California San Diego Health Sciences, Radiology Department, University of California San Diego Medical Center (United States)

    2015-04-15

    PurposeSerious complications can result from nontarget embolization during yttrium-90 (Y-90) transarterial radioembolization. Hepatoenteric artery coil embolization has been traditionally performed to prevent nontarget radioembolization. The U.S. Food and Drug Administration–approved Surefire Infusion System (SIS) catheter, designed to prevent reflux, is an alternative to coils. The hypothesis that quantifiable SIS procedural parameters are comparable to coil embolization was tested.MethodsFourteen patients aged 36–79 years with colorectal, neuroendocrine, hepatocellular, and other predominantly bilobar hepatic tumors who underwent resin microsphere Y-90 radioembolization using only the SIS catheter (n = 7) versus only detachable coils (n = 7) for nontarget protection were reviewed retrospectively. Procedure time, fluoroscopy time, contrast dose, radiation dose, and cost were evaluated.ResultsMultivariate analysis identified significant cohort differences in the procedural parameters evaluated (F(10, 3) = 10.39, p = 0.04). Between-group comparisons of the pretreatment planning procedure in the SIS catheter group compared to the coil embolization group demonstrated a significant reduction in procedure time (102.6 vs. 192.1 min, respectively, p = 0.0004), fluoroscopy time (14.3 vs. 49.7 min, respectively, p = 0.0016), and contrast material dose (mean dose of 174.3 vs. 265.0 mL, respectively, p = 0.0098). Procedural parameters were not significantly different between the two groups during subsequent dose delivery procedures. Overall cost of combined first-time radioembolization procedures was significantly less in the SIS group ($4252) compared to retrievable coil embolization ($11,123; p = 0.001).ConclusionThe SIS catheter results in a reduction in procedure time, fluoroscopy time, and contrast material dose and may be an attractive cost-effective alternative to detachable coil embolization for prevention of nontarget radioembolization.

  7. Attitudes Towards Catheter Ablation for Atrial Fibrillation

    DEFF Research Database (Denmark)

    Vadmann, Henrik; Pedersen, Susanne S; Nielsen, Jens Cosedis

    2015-01-01

    BACKGROUND: Catheter ablation for atrial fibrillation (AF) is an important but expensive procedure that is the subject of some debate. Physicians´ attitudes towards catheter ablation may influence promotion and patient acceptance. This is the first study to examine the attitudes of Danish...... cardiologists towards catheter ablation for AF, using a nationwide survey. METHODS AND RESULTS: We developed a purpose-designed questionnaire to evaluate attitudes towards catheter ablation for AF that was sent to all Danish cardiologists (n = 401; response n = 272 (67.8%)). There was no association between...... attitudes towards ablation and the experience or age of the cardiologist with respect to patients with recurrent AF episodes with a duration of 7 days and/or need for cardioversion. The majority (69%) expected a recurrence of AF after catheter ablation in more than 30% of the cases...

  8. Electric field modulation of magnetic anisotropy and microwave absorption properties in Fe50Ni50/Teflon composite films

    Directory of Open Access Journals (Sweden)

    Zhenjun Xia

    2016-05-01

    Full Text Available Fe50Ni50 nanoparticle films with the size about 6 nm were deposited by a high energetic cluster deposition source. An electric field of about 0 - 40 kV was applied on the sample platform when the films were prepared. The field assisted deposition technique can dramatically induce in-plane magnetic anisotropy. To probe the microwave absorption properties, the Fe50Ni50 nanoparticles were deliberately deposited on the dielectric Teflon sheet. Then the laminated Fe50Ni50/Teflon composites were used to do reflection loss scan. The results prove that the application of electric field is an effective avenue to improve the GHz microwave absorption performance of our magnetic nanoparticles films expressed by the movement of reflection loss peak to high GHz region for the composites.

  9. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Catheter Angiography ...

  10. Radiation protection cabin for catheter-directed liver interventions: operator dose assessment

    International Nuclear Information System (INIS)

    Maleux, Geert; Bosmans, Hilde; Bergans, Niki; Bogaerts, Ria

    2016-01-01

    The number and complexity of interventional radiological procedures and in particular catheter-directed liver interventions have increased substantially. The current study investigates the reduction of personal doses when using a dedicated radiation protection cabin (RPC) for these procedures. Operator and assistant doses were assessed for 3 series of 20 chemo-infusion/chemoembolisation interventions, including an equal number of procedures with and without RPC. Whole body doses, finger doses and doses at the level of knees and eyes were evaluated with different types of TLD-100 Harshaw dosemeters. Dosemeters were also attached on the three walls of the RPC. The operator doses were significantly reduced by the RPC, but also without RPC, the doses appear to be limited as a result of thorough optimisation with existing radiation protection tools. The added value of the RPC should thus be determined by the outcome of balancing dose reduction and other aspects such as ergonomic benefits. (authors)

  11. Technique of Peritoneal Catheter Placement under Fluoroscopic Guidance

    International Nuclear Information System (INIS)

    Abdel-Aal, A.K.; Gaddikeri, S.; Saddekni, S.

    2011-01-01

    Peritoneal catheters are mainly used for peritoneal dialysis in patients with end-stage renal disease. Other uses of this catheter include intraperitoneal chemotherapy and gene therapy for ovarian cancer and draining of uncontrolled refractory ascites in patients with liver cirrhosis. Traditionally, surgeons place most of these peritoneal catheters either by laparoscopy or open laparotomy. We detail our percutaneous approach to placing peritoneal catheters using fluoroscopic guidance. We emphasize the use of additional ultrasound guidance, including gray scale and color Doppler ultrasound, to determine the safest puncture site and to guide the initial needle puncture in order to avoid bowel perforation and injury to epigastric artery. We present our experience in placing peritoneal catheters using this technique in 95 patients with various indications. Fluoroscopic guided percutaneous placement of peritoneal catheters is a safe, minimally invasive, and effective alternative to open surgical or laparoscopic placement.

  12. Detection of electrophysiology catheters in noisy fluoroscopy images.

    Science.gov (United States)

    Franken, Erik; Rongen, Peter; van Almsick, Markus; ter Haar Romeny, Bart

    2006-01-01

    Cardiac catheter ablation is a minimally invasive medical procedure to treat patients with heart rhythm disorders. It is useful to know the positions of the catheters and electrodes during the intervention, e.g. for the automatization of cardiac mapping. Our goal is therefore to develop a robust image analysis method that can detect the catheters in X-ray fluoroscopy images. Our method uses steerable tensor voting in combination with a catheter-specific multi-step extraction algorithm. The evaluation on clinical fluoroscopy images shows that especially the extraction of the catheter tip is successful and that the use of tensor voting accounts for a large increase in performance.

  13. The feasibility of inducing mild therapeutic hypothermia after cardiac resuscitation using iced saline infusion via an intraosseous needle.

    Science.gov (United States)

    Mader, Timothy J; Walterscheid, Joshua K; Kellogg, Adam R; Lodding, Cynthia C

    2010-01-01

    This study was done, using a swine model of prolonged ventricular fibrillation out-of-hospital cardiac arrest, to determine the feasibility of inducing therapeutic hypothermia after successful resuscitation by giving an intraosseous infusion of iced saline. This study was IACUC approved. Liter bags of normal saline, after being refrigerated for at least 24h, were placed in an ice filled cooler. Female Yorkshire swine weighing between 27 and 35 kg were sedated and instrumented under general anesthesia. A temperature probe was inserted 10 cm into the esophagus. Ventricular fibrillation was electrically induced and allowed to continue untreated for 10 min. Animals were randomized to one of two resuscitation schemes for the primary study (N=53). One group had central intravenous access for drug delivery and the other had an intraosseous needle inserted into the proximal tibia for drug administration. Animals in which spontaneous circulation was restored were immediately cooled, for this secondary study, by means of a rapid, pump-assisted infusion of 1L of iced saline either through the intraosseous needle (n=8), the central access (n=6), or a peripheral intravenous catheter (n=7) in a systematic, non-randomized fashion. Room, animal, and saline temperatures were recorded at initiation and upon completion of infusion. The data were analyzed descriptively using Stata SE v8.1 for Macintosh. The baseline characteristics of all three groups were mathematically the same. The average ambient room temperature during the experimental sessions was 25.5 degrees C (SD=1.3 degrees C). There were no statistically significant differences between the three groups with regard to saline temperature, rate of infusion, or decrease in core body temperature. The decrease in core temperature for the intraosseous group was 2.8 degrees C (95% CI=1.8, 3.8) over the infusion period. Mild therapeutic hypothermia can be effectively induced in swine after successful resuscitation of prolonged

  14. 81mKr scintigraphic evaluation of hemodynamics in gynecologic malignancies under condition of Angiotensin II-induced hypertension

    International Nuclear Information System (INIS)

    Sumi, Yukiharu; Ozaki, Yutaka; Amemiya, Ken; Kyogoku, Shinsuke; Shirakata, Akihiro; Tamamoto, Fumihiko; Katayama, Hitoshi; Utsuno, Hiroshi; Kubota, Takeyoshi

    1992-01-01

    Transcatheter arterial infusion chemotherapy is one of the most useful therapeutic procedures for gynecologic malignancies. Although several reports have been published about Angiotensin II-induced hypertension chemotherapy and the efficacy of the method, there have been no reports to evaluate an application for gynecologic malignancies. We evaluated the usefulness of the method for gynecologic malignancies demonstrating the changes of hemodynamics of the tumor using 81m Kr scintigraphy. Thirteen patients with pathologically confirmed gynecologic malignancies were evaluated by angiography and continuous infusion of 81m Kr via the catheter with and without Angiotensin II. At first, continuous infusion of 81m Kr was performed under the superselective catheterization of the uterine artery. The radioactivities in the ROI were counted. Then, withdrew the catheter from the uterine artery to the internal iliac artery, and again continuously infused 81m Kr and counted the radioactivities in the same ROI. Finally, keeping the catheter in the internal iliac artery, Angiotensin II and 81m Kr were infused simultaneously. And counted the radioactivities. The radioactivities were highest when the catheter tip was placed in uterine arteries and lowest when the catheter tip was placed in internal iliac arteries. But radioactivities in the ROIs were definitely increased when Angiotensin II was used, even if the catheter tip was keeping in the internal iliac arteries. The optimal catheter position of transcatheter arterial chemotherapy for gynecologic malignancies is at proximal uterine artery. Since Angiotensin II-induced hypertension may increase blood flow of tumors, it seems to have indication for postoperative cases, highly advanced cases and cases with difficulties to perform superselective catheterization. From our experience, we believe chemotherapeutic agents must be administrated via catheter within 3 minutes after infusion of Angiotensin II. (author)

  15. UK Renal Registry 15th annual report: Chapter 8 UK multisite peritoneal dialysis access catheter audit for first PD catheters 2011.

    Science.gov (United States)

    Briggs, Victoria; Pitcher, David; Braddon, Fiona; Fogarty, Damian; Wilkie, Martin

    2013-01-01

    The central paradigm of effective peritoneal dialysis (PD) is an appropriate standard of PD catheter function. The aim of the project was to develop an effective national PD access audit which would identify an 'appropriate standard' of PD catheter function. The UK Renal Registry collected centre specific information on various PD access outcome measures including catheter functionality and post-insertion complications. The first PD access audit covering England, Northern Ireland and Wales was conducted during April to June 2012 looking at incident dialysis patients in 2011. Forty three data collection spreadsheets were returned from a total of 65 centres describing 917 PD catheter placements. The median age of PD patients was 61 years and 61.5% were male. The proportion of patients initiated on PD in comparison to HD was lower in socially deprived areas. There was a relationship between the timing of nephrology referral and the likelihood of surgical assessment regarding PD catheter placement. Patients with diabetes did not have higher rates of PD catheter failure or of early peritonitis. A comparative PD catheter audit has the potential to provide valuable information on an important patient related outcome measure and lead to an improvement in patient experience. There was wide variation between centres of PD catheter use for late presenting patients. Overall patients were more likely to get a PD catheter if they had been known to the service for more than 1 year. The percutaneous insertion technique was associated with a higher early (less than 2 week) peritonitis rate and more catheter flow problems. Copyright © 2013 S. Karger AG, Basel.

  16. Systematic review and meta-analysis: reminder systems to reduce catheter-associated urinary tract infections and urinary catheter use in hospitalized patients.

    Science.gov (United States)

    Meddings, Jennifer; Rogers, Mary A M; Macy, Michelle; Saint, Sanjay

    2010-09-01

    Prolonged catheterization is the primary risk factor for catheter-associated urinary tract infection (CAUTI). Reminder systems are interventions used to prompt the removal of unnecessary urinary catheters. To summarize the effect of urinary catheter reminder systems on the rate of CAUTI, urinary catheter use, and the need for recatheterization, we performed a systematic review and meta-analysis. Studies were identified in MEDLINE, the Cochrane Library, Biosis, the Web of Science, EMBASE, and CINAHL through August 2008. Only interventional studies that used reminders to physicians or nurses that a urinary catheter was in use or stop orders to prompt catheter removal in hospitalized adults were included. A total of 6679 citations were identified; 118 articles were reviewed, and 14 articles met the selection criteria. The rate of CAUTI (episodes per 1000 catheter-days) was reduced by 52% (P SMD) in the duration of catheterization was -1.11 overall (P = 070), including a statistically significant decrease in studies that used a stop order (SMD, -0.30; P = .001) but not in those that used a reminder (SMD, -1.54; P = .071). Recatheterization rates were similar in control and intervention groups. Urinary catheter reminders and stop orders appear to reduce the rate of CAUTI and should be strongly considered to enhance the safety of hospitalized patients.

  17. Steam-deformed Judkins-left guiding catheter with use of the GuideLiner catheter to deliver stents for anomalous right coronary artery

    Directory of Open Access Journals (Sweden)

    Toshiki Kuno

    2015-10-01

    Full Text Available Objective: Percutaneous coronary intervention for anomalous right coronary artery (RCA originating from the left coronary cusp is challenging because of our current inability to coaxially engage the guiding catheter. Methods: We report a case of an 88-year-old woman with non-ST segment elevation myocardial infarction, with an anomalous RCA origin. Using either the Judkins-Left catheter or Amplatz-Left catheter was difficult because of RCA ostium tortuosity. Thus, we used steam to deform the Judkins-Left catheter, but back-up support was insufficient to deliver the stent. Results: We used GuideLiner®, a novel pediatric catheter with rapid exchange/monorail systems, to enhance back-up support. Conclusions: We were able to successfully stent with both the deformed Judkins-Left guiding catheter and GuideLiner® for an anomalous RCA origin.

  18. No evidence of a clinically important effect of adding local infusion analgesia administrated through a catheter in pain treatment after total hip arthroplasty

    DEFF Research Database (Denmark)

    Specht, K.; Leonhardt, Jane Schwartz; Revald, Peter

    2011-01-01

    . Postoperatively, they were treated either with a solution of Ropivacain, Ketorolac, and Adrenaline (LINFA group) or placebo (placebo group) administered through a catheter to the hip 10 and 22 h after surgery. Pain score, opioid consumption, and length of stay (LOS) were evaluated. RESULTS: After adjustment...

  19. Cryo-balloon catheter localization in fluoroscopic images

    Science.gov (United States)

    Kurzendorfer, Tanja; Brost, Alexander; Jakob, Carolin; Mewes, Philip W.; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert

    2013-03-01

    Minimally invasive catheter ablation has become the preferred treatment option for atrial fibrillation. Although the standard ablation procedure involves ablation points set by radio-frequency catheters, cryo-balloon catheters have even been reported to be more advantageous in certain cases. As electro-anatomical mapping systems do not support cryo-balloon ablation procedures, X-ray guidance is needed. However, current methods to provide support for cryo-balloon catheters in fluoroscopically guided ablation procedures rely heavily on manual user interaction. To improve this, we propose a first method for automatic cryo-balloon catheter localization in fluoroscopic images based on a blob detection algorithm. Our method is evaluated on 24 clinical images from 17 patients. The method successfully detected the cryoballoon in 22 out of 24 images, yielding a success rate of 91.6 %. The successful localization achieved an accuracy of 1.00 mm +/- 0.44 mm. Even though our methods currently fails in 8.4 % of the images available, it still offers a significant improvement over manual methods. Furthermore, detecting a landmark point along the cryo-balloon catheter can be a very important step for additional post-processing operations.

  20. Dosimetric equivalence of nonstandard HDR brachytherapy catheter patterns

    International Nuclear Information System (INIS)

    Cunha, J. A. M.; Hsu, I-C.; Pouliot, J.

    2009-01-01

    Purpose: To determine whether alternative high dose rate prostate brachytherapy catheter patterns can result in similar or improved dose distributions while providing better access and reducing trauma. Materials and Methods: Standard prostate cancer high dose rate brachytherapy uses a regular grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. This study used CT datasets with 3 mm slice spacing from ten previously treated patients and digitized new catheters following three hypothetical catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA, and compared with the plan used for treatment. Irrelevant of catheter geometry, a plan must fulfill the RTOG-0321 dose criteria for target dose coverage (V 100 Prostate >90%) and organ-at-risk dose sparing (V 75 Bladder 75 Rectum 125 Urethra <<1 cc). Results: The three nonstandard catheter patterns used 16 nonparallel, straight divergent catheters, with entry points in the perineum. Thirty plans from ten patients with prostate sizes ranging from 26 to 89 cc were optimized. All nonstandard patterns fulfilled the RTOG criteria when the clinical plan did. In some cases, the dose distribution was improved by better sparing the organs-at-risk. Conclusion: Alternative catheter patterns can provide the physician with additional ways to treat patients previously considered unsuited for brachytherapy treatment (pubic arch interference) and facilitate robotic guidance of catheter insertion. In addition, alternative catheter

  1. Catheter ablation of epicardial ventricular tachycardia

    Directory of Open Access Journals (Sweden)

    Takumi Yamada, MD, PhD

    2014-08-01

    Full Text Available Ventricular tachycardias (VTs can usually be treated by endocardial catheter ablation. However, some VTs can arise from the epicardial surface, and their substrate can be altered only by epicardial catheter ablation. There are two approaches to epicardial catheter ablation: transvenous and transthoracic. The transvenous approach through the coronary venous system (CVS has been commonly used because it is easily accessible. However, this approach may be limited by the distribution of the CVS and insufficient radiofrequency energy delivery. Transthoracic epicardial catheter ablation has been developed to overcome these limitations of the transvenous approach. It is a useful supplemental or even preferred strategy to eliminate epicardial VTs in the electrophysiology laboratory. This technique has been applied for scar-related VTs secondary to often non-ischemic cardiomyopathy and sometimes ischemic cardiomyopathy, and idiopathic VTs as the epicardial substrates of these VTs have become increasingly recognized. When endocardial ablation and epicardial ablation through the CVS are unsuccessful, transthoracic epicardial ablation should be the next option. Intrapericardial access is usually obtained through a subxiphoidal pericardial puncture. This approach might not be possible in patients with pericardial adhesions caused by prior cardiac surgery or pericarditis. In such cases, a hybrid procedure involving surgical access with a subxiphoid pericardial window and a limited anterior or lateral thoracotomy might be a feasible and safe method of performing an epicardial catheter ablation in the electrophysiology laboratory. Potential complications associated with this technique include bleeding and collateral damage to the coronary arteries and phrenic nerve. Although the risk of these complications is low, electrophysiologists who attempt epicardial catheter ablation should know the complications associated with this technique, how to minimize their

  2. Catheter Angiography

    Medline Plus

    Full Text Available ... you are pregnant and discuss any recent illnesses, medical conditions, medications you're taking and allergies, especially ... is Catheter Angiography? Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical ...

  3. Catheter Angiography

    Medline Plus

    Full Text Available ... a catheter, x-ray imaging guidance and an injection of contrast material to examine blood vessels in ... technologies and, in most cases, a contrast material injection is needed to produce pictures of blood vessels ...

  4. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... angiogram may be performed in less than an hour; however, it may last several hours. top of ...

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... the American College of Radiology (ACR) and the European Society of Urogenital Radiology note that the available ... will regain their normal function within five to seven days. Rarely, the catheter punctures the artery, causing ...

  6. Catheter Angiography

    Medline Plus

    Full Text Available ... diagnosis and treatment in a single procedure. An example is finding an area of severe arterial narrowing, ... contrast material, your radiologist may advise that you take special medication for 24 hours before catheter angiography ...

  7. Catheter Angiography

    Medline Plus

    Full Text Available ... possible to combine diagnosis and treatment in a single procedure. Catheter angiography produces very detailed, clear and ... possible to combine diagnosis and treatment in a single procedure. An example is finding an area of ...

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... far outweighs the risk. If you have a history of allergy to x-ray contrast material, your ... Angiography (CTA) X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Catheter Angiography Sponsored ...

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... examine blood vessels in key areas of the body for abnormalities such as aneurysms and disease such ... to produce pictures of blood vessels in the body. Angiography is performed using: x-rays with catheters ...

  10. Catheter Angiography

    Medline Plus

    Full Text Available ... rare, and radiology departments are well-equipped to deal with them. There is a small risk that ... standard x-ray contrast. Catheter angiography should be done very cautiously—if at all—in patients who ...

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... atherosclerosis (plaque). The use of a catheter makes it possible to combine diagnosis and treatment in a ... the aorta in the chest or abdomen or its major branches. show the extent and severity of ...

  12. Catheter Angiography

    Medline Plus

    Full Text Available ... 20 minutes (or by using a special closure device). When the examination is complete, you may be ... contrast material, your radiologist may advise that you take special medication for 24 hours before catheter angiography ...

  13. Catheter Angiography

    Medline Plus

    Full Text Available ... rays ). top of page What are some common uses of the procedure? Catheter angiography is used to ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  14. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... and x-rays. Manufacturers of intravenous contrast indicate mothers should not breastfeed their babies for 24-48 ...

  15. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... possible to combine diagnosis and treatment in a single procedure. An example is finding an area of ...

  16. Catheter Angiography

    Medline Plus

    Full Text Available ... Once the catheter is guided to the area being examined, a contrast material is injected through the ... You should inform your physician of any medications being taken and if there are any allergies, especially ...

  17. Percutaneous transfemoral repositioning of malpositioned central venous catheters.

    Science.gov (United States)

    Hartnell, G G; Roizental, M

    1995-04-01

    Central venous catheters inserted by blind surgical placement may not advance into a satisfactory position and may require repositioning. Malpositioning via surgical insertion is common in patients in whom central venous catheters have previously been placed, as these patients are more likely to have central venous thrombosis and distortion of central venous anatomy. This is less of a problem when catheter placement is guided by imaging; however, even when insertion is satisfactory, central venous catheters may become displaced spontaneously after insertion (Fig. 1). Repositioning can be effected by direct manipulation using guidewires or tip-deflecting wires [1, 2], by manipulation via a transfemoral venous approach [3-5], and by injection of contrast material or saline [6]. Limitations of the direct approach include (1) the number and type of maneuvers that can be performed to effect repositioning when anatomy is distorted, (2) difficulty in accessing the catheter, and (3) the risk of introducing infection. Moreover, these patients are often immunosuppressed, and there is a risk of introducing infection by exposing and directly manipulating the venous catheter. Vigorous injection of contrast material or saline may be unsuccessful for the same reasons: It seldom exerts sufficient force to reposition large-caliber central venous catheters and may cause vessel damage or rupture if injection is made into a small or thrombosed vessel. We illustrate several alternative methods for catheter repositioning via a transfemoral venous approach.

  18. A prospective interventional study to examine the effect of a silver alloy and hydrogel-coated catheter on the incidence of catheter-associated urinary tract infection.

    Science.gov (United States)

    Chung, P Hy; Wong, C Wy; Lai, C Kc; Siu, H K; Tsang, D Nc; Yeung, K Y; Ip, D Km; Tam, P Kh

    2017-06-01

    Catheter-associated urinary tract infection is a major hospital-acquired infection. This study aimed to analyse the effect of a silver alloy and hydrogel-coated catheter on the occurrence of catheter-associated urinary tract infection. This was a 1-year prospective study conducted at a single centre in Hong Kong. Adult patients with an indwelling urinary catheter for longer than 24 hours were recruited. The incidence of catheter-associated urinary tract infection in patients with a conventional latex Foley catheter without hydrogel was compared with that in patients with a silver alloy and hydrogel-coated catheter. The most recent definition of urinary tract infection was based on the latest surveillance definition of the National Healthcare Safety Network managed by Centers for Disease Control and Prevention. A total of 306 patients were recruited with a similar ratio between males and females. The mean (standard deviation) age was 81.1 (10.5) years. The total numbers of catheter-days were 4352 and 7474 in the silver-coated and conventional groups, respectively. The incidences of catheter-associated urinary tract infection per 1000 catheter-days were 6.4 and 9.4, respectively (P=0.095). There was a 31% reduction in the incidence of catheter-associated urinary tract infection per 1000 catheter-days in the silver-coated group. Escherichia coli was the most commonly involved pathogen (36.7%) of all cases. Subgroup analysis revealed that the protective effect of silver-coated catheter was more pronounced in long-term users as well as female patients with a respective 48% (P=0.027) and 42% (P=0.108) reduction in incidence of catheter-associated urinary tract infection. The mean catheterisation time per person was the longest in patients using a silver-coated catheter (17.0 days) compared with those using a conventional (10.8 days) or both types of catheter (13.6 days) [P=0.01]. Silver alloy and hydrogel-coated catheters appear to be effective in preventing catheter

  19. Removal of non-deflatable retained foley catheter in the bladder by percutaneous puncture of catheter balloon

    International Nuclear Information System (INIS)

    Yoo, Jae Duk; Kim, Jae Kyu; Park, Jin Gyun; Chung, Hyon De

    1988-01-01

    Nondeflatable Foley catheter in the bladder is an uncommon event. We recently experienced a patient in whom the urologist were unable to remove a Foley catheter with cystoscope due to public bone fractures. The procedure, which was successfully carried out, consists of puncturing the ballon under fluoroscope.

  20. Continuous-infusion adriamycin

    International Nuclear Information System (INIS)

    Benjamin, R.S.; Chawla, S.P.; Ewer, M.S.; Hortobagyi, G.N.

    1986-01-01

    This chapter discusses the diminished cardiotoxicity as well as diminished nausea and vomiting with continuous infusions of adriamycin to patients undergoing radiation therapy, particularly with infusions of 48 hours or longer, and best with 96-hour infusions, the longest duration that has been studied systematically. In breast cancer, data show that more adriamycin is better, but only for a selected subgroup of patients: those with complete remission. The diminished cardiotoxicity makes the use of adriamycin more attractive in the adjuvant situation, where increased safety will decrease the chances of long-term complications and make retreatment easy for cured patients who develop second malignancies

  1. Iatrogenic Bowel Injury at Exchange of Supra-Pubic Catheter

    LENUS (Irish Health Repository)

    Foran, AT

    2018-04-01

    Suprapubic catheter insertion and exchange is a common urological procedure, but it is not without risks and complications. While bowel perforation is a recognised complication at suprapubic catheter insertion, it is not commonly reported at suprapubic catheter exchange. We report our experience of recognition, diagnosis and subsequent successful management of the most important complication related to suprapubic catheters.

  2. Intra-arterial urokinase infusion in the very early stage of cerebral artery occlusion and stenosis at their main trunks

    Energy Technology Data Exchange (ETDEWEB)

    Shizume, Kengo

    1988-02-01

    Eight patients, aged 43 approx. 78 years, with occlusion or stenosis of intracranial cerebral arteries at their main trunks were treated with intraarterial urokinase infusion within 5 hours after onset. Intracranial hemorrhage was excluded and low density area were absent on the first CT examination. Three of eight patients were diagnosed as embolism because of the sudden onset and coexisted atrial fibrillation. Middle cerebral artery (MCA) occlusion was disclosed in 5 cases. MCA stenosis, internal carotid artery (ICA) occlusion and ICA stenosis were revealed in each one case by angiography. 24 approx. 72 x 10/sup 4/ units of urokinase was infused manually into the common or internal carotid artery through the catheter for angiography within 10 approx. 50 minutes. Anticoagulants were not used exept in one case. Four patients were immediately improved after urokinase infusion and discharged without any significant sequelae. Patients with mild or moderate disability due to thrombosis recovered and those with severe symptoms due to embolism scarcely improved. The follow-up CT scans revealed hemorragic infarction in only one case (embolism of MCA), although symptoms did not deteriorate. After infusion of 48 x 10/sup 4/ units of urokinase for 50 minutes, fibrinogen and ..cap alpha../sub 2/-antiplasmin (..cap alpha../sub 2/ AP) decreased to 34 % and 21 % of the original values, respectively. Although the decrease of fibrinogen level is a disadvantage in this therapy, the decrease in the level of ..cap alpha../sub 2/ AP near the clot is probably indispensable for the fibrinolytic effect. If the endothelial damage of ischemic arteries still remain mild and reversible, hemorrhagic complication after reperfusion may rarely take place. It is suggested that intraarterial urokinase infusion is a relatively safe and effective therapy of cerebral artery occlusion and stenosis in strictly selected cases.

  3. The bowed catheter sign: a risk for pericardial tamponade

    Energy Technology Data Exchange (ETDEWEB)

    Towbin, Richard [Phoenix Children' s Hospital, Department of Radiology, Phoenix, AZ (United States)

    2008-03-15

    The use of a central venous catheter (CVC) has become commonplace in the care of children with a wide variety of medical and surgical problems. Complications resulting from the insertion of these catheters are well recognized and can be life-threatening. When a temporary CVC or other catheter is inserted into the central venous system it is secured to the skin with a combination of sutures and sterile dressing. This fixes the catheter in place and does not allow it to retract, thereby putting pressure on the right atrial wall via the catheter tip if it is too long. The probability of wall penetration is increased if a catheter or device is tapered at the point of contact. The purpose of this case report is to present the bowed catheter sign and to review the anatomy of the cavotricuspid isthmus, a possible predisposing factor to cardiac perforation and tamponade. (orig.)

  4. The bowed catheter sign: a risk for pericardial tamponade

    International Nuclear Information System (INIS)

    Towbin, Richard

    2008-01-01

    The use of a central venous catheter (CVC) has become commonplace in the care of children with a wide variety of medical and surgical problems. Complications resulting from the insertion of these catheters are well recognized and can be life-threatening. When a temporary CVC or other catheter is inserted into the central venous system it is secured to the skin with a combination of sutures and sterile dressing. This fixes the catheter in place and does not allow it to retract, thereby putting pressure on the right atrial wall via the catheter tip if it is too long. The probability of wall penetration is increased if a catheter or device is tapered at the point of contact. The purpose of this case report is to present the bowed catheter sign and to review the anatomy of the cavotricuspid isthmus, a possible predisposing factor to cardiac perforation and tamponade. (orig.)

  5. Steam-deformed Judkins-left guiding catheter with use of the GuideLiner(®) catheter to deliver stents for anomalous right coronary artery.

    Science.gov (United States)

    Kuno, Toshiki; Fujisawa, Taishi; Yamazaki, Hiroyuki; Motoda, Hiroyuki; Kodaira, Masaki; Numasawa, Yohei

    2015-01-01

    Percutaneous coronary intervention for anomalous right coronary artery (RCA) originating from the left coronary cusp is challenging because of our current inability to coaxially engage the guiding catheter. We report a case of an 88-year-old woman with non-ST segment elevation myocardial infarction, with an anomalous RCA origin. Using either the Judkins-Left catheter or Amplatz-Left catheter was difficult because of RCA ostium tortuosity. Thus, we used steam to deform the Judkins-Left catheter, but back-up support was insufficient to deliver the stent. We used GuideLiner®, a novel pediatric catheter with rapid exchange/monorail systems, to enhance back-up support. We were able to successfully stent with both the deformed Judkins-Left guiding catheter and GuideLiner® for an anomalous RCA origin.

  6. Catheter Associated Urinary Tract Infection Prevention bundle

    Directory of Open Access Journals (Sweden)

    O. Zarkotou

    2017-01-01

    Full Text Available Catheter-associated urinary tract infections (CAUTI are among the most common healthcare-associated infections, and potentially lead to significant morbidity and mortality. Multifaceted infection control strategies implemented as bundles can prevent nosocomial infections associated with invasive devices such as CAUTIs. The components of the CAUTI bundle proposed herein, include appropriate indications for catheterization and recommendations for the procedures of catheter insertion and catheter maintenance and care. Avoiding unnecessary urinary catheter use is the most effective measure for their prevention. To minimize the risk of CAUTI, urinary catheters should be placed only when a clinical valid indication is documented and they should be removed as soon as possible; alternatives to catheterization should also be considered. Aseptic insertion technique, maintenance of closed drainage system and strict adherence to hand hygiene are essential for preventing CAUTI. The successful implementation of the bundle requires education and training for all healthcare professionals and evaluation of surveillance data.

  7. Central venous catheter insertion problem solving using intravenous catheter: technical communication

    Directory of Open Access Journals (Sweden)

    Alemohammad M

    2013-02-01

    Full Text Available Insertion of central venous catheter is an accepted method for hemodynamic monitor-ring, drug and fluid administration, intravenous access, hemodialysis and applying cardiac pace-maker in hospitalized patients. This procedure can be associated with severe complications. The aim of this article is to provide a practical approach to prevent catheter malposition in states that the guide wire will not pass freely.During central venous insertion in internal jugular vein using modified seldinger technique, when after venous insertion, the passage of the guide wire shows difficulties and don’t pass freely, insertion of an intravenous cannula over the wire and re-insertion of the wire can help to prevent malposition of the wire and the catheter. Use of an intravenous cannula over the guide, in situations that the guide wire cannot pass freely among the needle inserted in internal jugular vein, and re-insertion of the guide can probably prevent or reduce the tissue or vascular trauma and the associated complica-tions. This simple maneuver can be helpful in difficult cases especially in cardiac surgery patients who receive high dose heparin and it is necessary to avoid traumatize-tion of carotid artery.

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... story about radiology? Share your patient story here Images × Image Gallery Interventional radiologist performing an angiography exam View ... ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Catheter Angiography Sponsored by Please note ...

  9. Thrombolytic treatment for acute ischemic cerebral stroke: intraarterial urokinase infusion vs. intravenous heparin and urokinase infusion

    International Nuclear Information System (INIS)

    Ko, Gi Young; Suh, Dae Chul; Lee, Jae Hong; Kim, Jun Hyoung; Choi, Choong Gon; Lee, Ho Kyu; Lee, Myoung Chong

    1996-01-01

    To evaluate the efficacy and limitation of intra-arterial urokinase (IAUK) infusion for treatment of acute cerebral stroke. Twenty-seven acute cerebral stroke patients treated with IAUK infusion within six hours of stroke onset were reviewed. All patients showed normal initial brain findings on CT. In 21 patients, urokinase(5-15 x 10 5 IU) was administered through a microcatheter placed into or proximal to occluded segment. Mechanical disruption of thrombus by guidewire was performed in 17 patients. Angiographic and clinical responses and complications after IAUK infusion, were evaluated and the results were compared with those of intravenous heparin(N=19) and urokinase infusion(N=19). Complete or partial angiographic recanalization of occluded segment was found in 18 patients (67%), and neurologic improvement was followed in 14 patients(52%). The degree of improvement on the stroke scale score after IAUK infusion was statistically more significant(p<0.05) than that shown after intravenous heparin and urokinase infusion. Complications after IAUK infusion were large(15%) and small amount intracerebral hemorrhage(15%), contrast leakage into brain parenchyma(11%), and gastrointestinal bleeding(4%). Between the IAVK and the intravenous urokinase infusion group, differences in extent and types of complications were statistically insignificant, but were significantly higher in those two groups than in the intravenous heparin infusion group. IAUK infusion may be effective for the treatment of acute cerebral stroke

  10. Subcutaneous insulin infusion: change in basal infusion rate has no immediate effect on insulin absorption rate

    International Nuclear Information System (INIS)

    Hildebrandt, P.; Birch, K.; Jensen, B.M.; Kuehl, C.

    1986-01-01

    Eight insulin-dependent diabetic patients were simultaneously given subcutaneous infusions (1.12 IU/h each) of 125 I-labeled Actrapid insulin in each side of the abdominal wall. After 24 h of infusion, the size of the infused insulin depots was measured by external counting for 5 h. The basal infusion rate was then doubled in one side and halved in the other for the next 4 h. Finally, 1.12 IU/h of insulin was given in both sides of the abdominal wall for an additional 3 h. The changes in the size of the depots were measured, and the absorption rates for each hour were calculated. During the first 5 h of infusion, the depot size was almost constant (approximately 5 IU) with an absorption rate that equaled the infusion rate. Doubling the infusion rate led to a significant increase in depot size, but the absorption rate remained unchanged for the first 3 h, and only thereafter was a significant increase seen. When the infusion rate was reduced to the initial 1.12 IU/h, the absorption rate remained elevated during the next 3 h. Correspondingly, when the infusion rate was decreased, the depot size also decreased, but the absorption rate remained unchanged for the first 3 h. The results show that a change in the basal insulin infusion rate does not lead to any immediate change in the insulin absorption rate. This should be considered when planning an insulin-infusion program that includes alteration(s) in the basal-rate setting

  11. An epidural catheter removal after recent percutaneous coronary intervention and coronary artery stenting: Epidural catheter and antiaggregation therapy

    Directory of Open Access Journals (Sweden)

    Joksić Nikola

    2016-01-01

    Full Text Available Introduction: Anticoagulation and antiplatelet therapy in the presence of the epidural catheter is still controversial. It is well known that dual antiplatelet therapy is indicated for 12 months after the placement of drug-eluting stents (DES. Removal of an epidural catheter during that period is related to an increased risk of stent occlusion in case of discontinuation of platelet function inhibitors or, on the other hand, increased risk of epidural hematoma associated with neurological deficit if suppressed platelet function is still present. Case Report: Here we present a case of a 63-year-old man who was admitted to Institute for Cardiovascular Diseases Dedinje for elective aortic surgery. Before the induction, an epidural catheter was inserted at the Th10-Th11 epidural space. Uneventful surgery was performed under the combined epidural and general anesthesia. On the 2nd postoperative day, the patient sustained a ST depression myocardial infarction treated with percutaneous coronary intervention with DES placement, while epidural catheter was still in place. Dual antiplatelet therapy with 600mg of clopidogrel, 100 mg of acetilsalicylic acid (ASA and low molecular weight heparin (LMWH were started during the procedure. The next day, clopidogrel (75 mg and ASA (100 mg were continued as well as LMWH. The decision to remove the epidural catheter was made on the 9th postoperative day, after platelet aggregation assays were performed. Six hours after catheter removal the patient again received clopidogrel, ASA and LMWH. There were no signs of epidural hematoma. Conclusion: This case shows that point-of-care testing with platelet aggregation assays may be useful in increasing the margin of safety for epidural catheter removal during dual antiplatelet therapy.

  12. Urethral catheters: can we reduce use?

    NARCIS (Netherlands)

    Broek, P.J. van den; Wille, J.C.; Benthem, B.H.B. van; Perenboom, R.J.M.; Akker-van Marle, M.E. van den; Nielen, A.M.A.

    2011-01-01

    Indwelling urinary catheters are the main cause of healthcare-associated urinary tract infections. It can be expected that reduction of the use of urinary catheters will lead to decreased numbers of urinary tract infection. The efficacy of an intervention programme to improve adherence to

  13. Bacterial Biofilms and Catheters: A Key to Understanding Bacterial Strategies in Catheter-Associated Urinary Tract Infection

    Directory of Open Access Journals (Sweden)

    J Curtis Nickel

    1992-01-01

    Full Text Available Despite major technological improvements in catheter drainage systems, the indwelling Foley catheter remains the most common cause of nosocomial infection in medical practice. By approaching this common complicated urinary tract infection from the perspective of the biofilm strategy bacteria appear to use to overcome obstacles to produce bacteriuria, one appreciates a new understanding of these infections. An adherent biofilm of bacteria in their secretory products ascends the luminal and external surface of the catheter and drainage system from a contaminated drainage spigot or urethral meatus into the bladder. If the intraluminal route of bacterial ascent is delayed by strict sterile closed drainage or addition of internal modifications to the system, the extraluminal or urethral route assumes greater importance in the development of bacteriuria, but takes significantly longer. Bacterial growth within these thick coherent biofilms confers a large measure of relative resistance to antibiotics even though the individual bacterium remains sensitive, thus accounting for the failure of antibiotic therapy. With disruption of the protective mucous layer of the bladder by mechanical irritation, the bacteria colonizing the catheter can adhere to the bladder’s mucosal surface and cause infection. An appreciation of the role of bacterial biofilms in these infections should suggest future directions for research that may ultimately reduce the risk of catheter-associated infection.

  14. Spontaneous rotation of the monorail-type guide extension support catheter during advancement of a curved guiding catheter: the potential hazard of twisting with the coronary guidewire.

    Science.gov (United States)

    Hashimoto, Sho; Takahashi, Akihiko; Yamada, Takeshi; Mizuguchi, Yukio; Taniguchi, Norimasa; Hata, Tetsuya; Nakajima, Shunsuke

    2017-11-20

    The extension support guiding catheter has been used to perform complex percutaneous coronary intervention to increase back-up support for the guiding catheter or to ensure deep intubation for device delivery. However, because of its monorail design, advancement of the stent into the distal extension tubing segment is sometimes problematic. Although this problem is considered due to simple collision of the stent, operators have observed tangling between a monorail extension catheter and coronary guidewire in some patients. To examine movement of the collar of the extension guide catheter during advancement of the guiding catheter, we set up an in vitro model in which the guiding catheter had two curves. Rotation of the extension guide catheter was examined by both fluoroscopic imaging and movement of the hub of the proximal end of the catheter. During advancement in the first curve, the collar moved toward the outer side of the curve of the guiding catheter as the operator pushed the shaft of the extension guiding catheter, which overrode the guidewire. After crossing the first curve, the collar moved again to the outer side of the second curve (the inner side of the first curve) of the mother catheter, and then, another clockwise rotation was observed in the proximal hub. Consequently, the collar and tubing portion of the extension guide catheter rotated 360° around the coronary guidewire, and the monorail extension catheter and guidewire became tangled. There is a potential risk of unintentional twisting with the guidewire during advancement into the curved guiding catheter because of its monorail design.

  15. Thermoluminescent signal fading of encapsulated lif: Mg,Ti detectors in PTFE-Teflon registered trademark

    International Nuclear Information System (INIS)

    Sasho Nikolovski, Sasho; Nikolovska, Lidija; Velevska, Marija; Velev, Velko

    2010-01-01

    Fading is a process when the latent information of a detector is unintentionally lost mainly due to the thermal influence. Thermoluminescent (TL) detectors have different sensitivities as far as the fading effect. Encapsulated TL detectors mounted within shielded filter holders are used during the personal monitoring of occupationally exposed persons in R. Macedonia. PTFE-Teflon registered trademark polymer is an example of encapsulation material that has a temperature resistance and it allows the luminescence signal to pass through. Since the encapsulated TL detectors cannot be submitted to annealing treatment in an oven, another fading reduction method is needed. The TL evaluation method suggested in this work is based on a specific glow-curve region. Irradiations were conducted using 90Sr/90Y source. Post-irradiation fade investigations were conducted for evaluation periods that varied up to 4 months. Two areas of the TL glow-curve were selected with the WimRems software. They correspond to the high and the low fading emission peaks (the lower temperature peaks display a greater degree of thermal fading than the higher temperature peaks). Post-irradiation fade is a contributing factor that affects the response of a thermoluminescent (TL) phosphor as a function of time. PTFE - Polytetrafluoroethylene most well known by the DuPont brand name Teflon registered trademark. (Author)

  16. Continuous Transversus Abdominis Plane Nerve Blocks: Does Varying Local Anesthetic Delivery Method-Automatic Repeated Bolus Versus Continuous Basal Infusion-Influence the Extent of Sensation to Cold?: A Randomized, Triple-Masked, Crossover Study in Volunteers.

    Science.gov (United States)

    Khatibi, Bahareh; Said, Engy T; Sztain, Jacklynn F; Monahan, Amanda M; Gabriel, Rodney A; Furnish, Timothy J; Tran, Johnathan T; Donohue, Michael C; Ilfeld, Brian M

    2017-04-01

    It remains unknown whether continuous or scheduled intermittent bolus local anesthetic administration is preferable for transversus abdominis plane (TAP) catheters. We therefore tested the hypothesis that when using TAP catheters, providing local anesthetic in repeated bolus doses increases the cephalad-caudad cutaneous effects compared with a basal-only infusion. Bilateral TAP catheters (posterior approach) were inserted in 24 healthy volunteers followed by ropivacaine 2 mg/mL administration for a total of 6 hours. The right side was randomly assigned to either a basal infusion (8 mL/h) or bolus doses (24 mL administered every 3 hours for a total of 2 bolus doses) in a double-masked manner. The left side received the alternate treatment. The primary end point was the extent of sensory deficit as measured by cool roller along the axillary line at hour 6 (6 hours after the local anesthetic administration was initiated). Secondary end points included the extent of sensory deficit as measured by cool roller and Von Frey filaments along the axillary line and along a transverse line at the level of the anterior superior iliac spine at hours 0 to 6. Although there were statistically significant differences between treatments within the earlier part of the administration period, by hour 6 the difference in extent of sensory deficit to cold failed to reach statistical significance along the axillary line (mean = 0.9 cm; SD = 6.8; 95% confidence interval -2.0 to 3.8; P = .515) and transverse line (mean = 2.5 cm; SD = 10.1; 95% confidence interval -1.8 to 6.8; P = .244). Although the difference between treatments was statistically significant at various early time points for the horizontal, vertical, and estimated area measurements of both cold and mechanical pressure sensory deficits, no comparison remained statistically significant by hour 6. No evidence was found in this study involving healthy volunteers to support the hypothesis that changing the local anesthetic

  17. Catheter placement for lysis of spontaneous intracerebral hematomas: does a catheter position in the core of the hematoma allow more effective and faster hematoma lysis?

    Science.gov (United States)

    Malinova, Vesna; Schlegel, Anna; Rohde, Veit; Mielke, Dorothee

    2017-07-01

    For the fibrinolytic therapy of intracerebral hematomas (ICH) using recombinant tissue plasminogen activator (rtPA), a catheter position in the core of the hematoma along the largest clot diameter was assumed to be optimal for an effective clot lysis. However, it never had been proven that core position indeed enhances clot lysis if compared with less optimal catheter positions. In this study, the impact of the catheter position on the effectiveness and on the time course of clot lysis was evaluated. We analyzed the catheter position using a relative error calculating the distance perpendicular to the catheter's center in relation to hematoma's diameter and evaluated the relative hematoma volume reduction (RVR). The correlation of the RVR with the catheter position was evaluated. Additionally, we tried to identify patterns of clot lysis with different catheter positions. The patient's outcome at discharge was evaluated using the Glasgow outcome score. A total of 105 patients were included in the study. The mean hematoma volume was 56 ml. The overall RVR was 62.7 %. In 69 patients, a catheter position in the core of the clot was achieved. We found no significant correlation between catheter position and hematoma RVR (linear regression, p = 0.14). Core catheter position leads to more symmetrical hematoma RVR. Faster clot lysis happens in the vicinity of the catheter openings. We found no significant difference in the patient's outcome dependent on the catheter position (linear regression, p = 0.90). The catheter position in the core of the hematoma along its largest diameter does not significantly influence the effectiveness of clot lysis after rtPA application.

  18. Types of urethral catheter for reducing symptomatic urinary tract infections in hospitalised adults requiring short-term catheterisation: multicentre randomised controlled trial and economic evaluation of antimicrobial- and antiseptic-impregnated urethral catheters (the CATHETER trial).

    Science.gov (United States)

    Pickard, R; Lam, T; Maclennan, G; Starr, K; Kilonzo, M; McPherson, G; Gillies, K; McDonald, A; Walton, K; Buckley, B; Glazener, C; Boachie, C; Burr, J; Norrie, J; Vale, L; Grant, A; N'dow, J

    2012-11-01

    Catheter-associated urinary tract infection (CAUTI) is a major preventable cause of harm for patients in hospital and incurs significant costs for health-care providers such as the UK NHS. Many preventative strategies and measures have been introduced to minimise CAUTI risk, including the use of antimicrobial catheters. However, there is considerable uncertainty regarding their usefulness in terms of reducing symptomatic CAUTI, and whether or not they are cost-effective. Do antimicrobial catheters reduce the rate of symptomatic urinary tract infection (UTI) during short-term hospital use and is their use cost-effective for the UK NHS? A pragmatic multicentre UK randomised controlled trial comparing three catheters as they would be used in the UK NHS: antimicrobial-impregnated (nitrofurazone) and antiseptic-coated (silver alloy) catheters with the standard polytetrafluoroethylene (PTFE)-coated catheters. Economic evaluation used a decision model populated with data from the trial. Sensitivity analysis was used to explore uncertainty. Relevant clinical departments in 24 NHS hospitals throughout the UK. Adults requiring temporary urethral catheterisation for a period of between 1 and 14 days as part of their care, predominantly as a result of elective surgery. Eligible participants were randomised 1 : 1 : 1 to one of three types of urethral catheter in order to make the following pragmatic comparisons: nitrofurazone-impregnated silicone catheter compared with standard PTFE-coated latex catheter; and silver alloy-coated hydrogel latex catheter compared with standard PTFE-coated latex catheter. The primary outcome for clinical effectiveness was the incidence of UTI at any time up to 6 weeks post randomisation. This was defined as any symptom reported during catheterisation, up to 3 days or 1 or 2 weeks post catheter removal or 6 weeks post randomisation combined with a prescription of antibiotics, at any of these times, for presumed symptomatic UTI. The primary economic

  19. Catheter Angiography

    Medline Plus

    Full Text Available ... key areas of the body for abnormalities such as aneurysms and disease such as atherosclerosis (plaque). The use of a catheter makes ... including the: brain neck heart chest abdomen (such as the kidneys and liver) pelvis legs and feet ...

  20. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Catheter Angiography? Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical conditions. ...

  1. Radiologic Placement of Tunneled Central Venous Catheters in Pediatric Patients

    International Nuclear Information System (INIS)

    Kim, Eun Ji; Song, Soon Young; Cho, On Koo; Koh, Byung Hee; Kim, Yong Soo; Jeong, Woo Kyoung; Lee, Yong Ho

    2010-01-01

    We evaluated the technical success and complication rates associated with the radiological placement of tunneled central venous catheters in pediatric patients. Between May 1, 2005 and March 31, 2008, a total of 46 tunneled central venous catheters were placed in 34 children (M:F = 22:12; mean age, 9.9 years [9 months to 16.8 years]). All procedures were performed under ultrasonographic and fluoroscopic guidance. Follow-up data were obtained through the retrospective review of the medical records. We used the Kaplan-Meier survival method for the evaluation of survival rate of the catheters. All procedures were technically successful. The observed periprocedural complications included hematoma formation in three patients. The mean catheter life was 189.3 days (total, 8710 days; range, 7-810). Catheters were removed due to death (n=9), the end of treatment (n=8), catheter sepsis (n=4), malfunction (n=8), and accidental removal (n=4). The rate of catheter sepsis and malfunction was 0.459 and 0.919 for every 1000 catheter days, respectively. The expected mean catheter life was 479.6 days as per the Kaplan- Meier analysis. The results suggest that the radiologic placement of a tunneled central venous catheter is an effective technique with a high technical success rate and low complication rate

  2. Radiologic Placement of Tunneled Central Venous Catheters in Pediatric Patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Ji; Song, Soon Young; Cho, On Koo; Koh, Byung Hee; Kim, Yong Soo; Jeong, Woo Kyoung; Lee, Yong Ho [Hanyang University College of Medicine, Seoul (Korea, Republic of)

    2010-08-15

    We evaluated the technical success and complication rates associated with the radiological placement of tunneled central venous catheters in pediatric patients. Between May 1, 2005 and March 31, 2008, a total of 46 tunneled central venous catheters were placed in 34 children (M:F = 22:12; mean age, 9.9 years [9 months to 16.8 years]). All procedures were performed under ultrasonographic and fluoroscopic guidance. Follow-up data were obtained through the retrospective review of the medical records. We used the Kaplan-Meier survival method for the evaluation of survival rate of the catheters. All procedures were technically successful. The observed periprocedural complications included hematoma formation in three patients. The mean catheter life was 189.3 days (total, 8710 days; range, 7-810). Catheters were removed due to death (n=9), the end of treatment (n=8), catheter sepsis (n=4), malfunction (n=8), and accidental removal (n=4). The rate of catheter sepsis and malfunction was 0.459 and 0.919 for every 1000 catheter days, respectively. The expected mean catheter life was 479.6 days as per the Kaplan- Meier analysis. The results suggest that the radiologic placement of a tunneled central venous catheter is an effective technique with a high technical success rate and low complication rate.

  3. Management of Non- Deflating Foley Suprapubic Catheters - A ...

    African Journals Online (AJOL)

    The procedure described uses a 10 ml syringe and needle passed through the lumen of the catheter to puncture the inner surface of the catheter balloon and thus deflate it. Because the catheter balloon does not burst in this procedure there is no risk of balloon fragmentation or subsequent stone formation. The technique is ...

  4. Urethral catheters: can we reduce use?

    Directory of Open Access Journals (Sweden)

    van den Akker-van Marle M Elske

    2011-05-01

    Full Text Available Abstract Background Indwelling urinary catheters are the main cause of healthcare-associated urinary tract infections. It can be expected that reduction of the use of urinary catheters will lead to decreased numbers of urinary tract infection. Methods The efficacy of an intervention programme to improve adherence to recommendations to reduce the use of urethral catheters was studied in a before-after comparison in ten Dutch hospitals. The programme detected barriers and facilitators and each individual facility was supported with developing their own intervention strategy. Outcome was evaluated by the prevalence of catheters, alternatives such as diapers, numbers of urinary tract infections, the percentage of correct indications and the duration of catheterization. The costs of the implementation as well as the catheterization were evaluated. Results Of a population of 16,495 hospitalized patients 3335 patients of whom 2943 were evaluable for the study, had a urethral catheter. The prevalence of urethral catheters decreased insignificantly in neurology (OR 0.93; 95% CI 0.77 - 1.13 and internal medicine wards (OR 0.97; 95% CI 0.83 - 1.13, decreased significantly in surgical wards (OR 0.84; 95% CI 0.75 - 0.96, but increased significantly in intensive care (IC and coronary care (CC units (OR 1.48; 95% CI 1.01 - 2.17. The use of alternatives was limited and remained so after the intervention. Duration of catheterization decreased insignificantly in IC/CC units (ratio after/before 0.95; 95% CI 0.78 - 1.16 and neurology (ratio 0.97; 95% CI 0.80 - 1.18 and significantly in internal medicine (ratio 0.81; 95% CI 0.69 - 0.96 and surgery wards (ratio 0.80; 95% CI 0.71 - 0.90. The percentage of correct indications on the day of inclusion increased from 50 to 67% (p Conclusion Targeted implementation of recommendations from an existing guideline can lead to better adherence and cost savings. Especially, hospitals which use a lot of urethral catheters or

  5. Infusion MR arteriography during hepatic arterial infusion chemotherapy. Evaluation of clinical usefulness

    International Nuclear Information System (INIS)

    Uchino, Minako; Takizawa, Kenji

    2003-01-01

    We developed a new method of infusion MR arteriography (IMRA) via an implantable port system using an infusion pump for the evaluation of drug distribution during hepatic arterial infusion chemotherapy. The purposes of this study were to optimize the method and evaluate its clinical usefulness. We used 3D-T1 turbo field echo (TFE) as the most suitable sequence for IMRA according to the results of a phantom model experiment. We examined 33 cases of liver cancer that had been treated by arterial infusion chemotherapy via the port system. The following investigations were performed: degree of tumor enhancement, intra- and extra- hepatic perfusion abnormality, and related toxicity. The evaluation of images was performed separately by two radiologists. IMRA provided good images of contrast enhancement, to reveal the perfusion patterns. The treatment response rate in the tumor group with well enhancement was higher than that of the group with poor enhancement (p<0.0001). Extrahepatic perfusion was well visualized and was correlated with toxicity (p<0.0001). IMRA is a useful method to evaluate drug perfusion for the optimization of arterial infusion chemotherapy. (author)

  6. An audit of hospital based outpatient infusions and a pilot program of community-based monoclonal antibody infusions.

    LENUS (Irish Health Repository)

    Doran, J-P

    2012-02-01

    INTRODUCTION: Infliximab, a chimeric monoclonal antibody to tumour necrosis factor alpha, is administered as an intravenous infusion requiring a costly hospital day case or inpatient admission. METHODS: An audit of all current therapies given by intravenous infusions in an outpatient setting in St Vincent\\'s University Hospital (SVUH) was undertaken. Furthermore, in conjunction with TCP homecare, we established in a general practise health clinic, the first Irish community infusion centre for the administration of infliximab in August 2006. RESULTS: All outpatient departments indicated that they would favour a centralized hospital infusion unit. There were no adverse events and the mean global satisfaction improved in the community infliximab infusion pilot programme of seven patients. CONCLUSION: This study suggests efficiencies in providing centralized infusion facilities, while the community based infusion of infliximab is feasible and safe in this small cohort and identifies the community infusion unit as a viable and cost efficient alternative for administration of infliximab.

  7. 21 CFR 880.5200 - Intravascular catheter.

    Science.gov (United States)

    2010-04-01

    ... Devices § 880.5200 Intravascular catheter. (a) Identification. An intravascular catheter is a device that consists of a slender tube and any necessary connecting fittings and that is inserted into the patient's vascular system for short term use (less than 30 days) to sample blood, monitor blood pressure, or...

  8. Reducing unnecessary urinary catheter use and other strategies to prevent catheter-associated urinary tract infection: an integrative review.

    Science.gov (United States)

    Meddings, Jennifer; Rogers, Mary A M; Krein, Sarah L; Fakih, Mohamad G; Olmsted, Russell N; Saint, Sanjay

    2014-04-01

    Catheter-associated urinary tract infections (CAUTI) are costly, common and often preventable by reducing unnecessary urinary catheter (UC) use. To summarise interventions to reduce UC use and CAUTIs, we updated a prior systematic review (through October 2012), and a meta-analysis regarding interventions prompting UC removal by reminders or stop orders. A narrative review summarises other CAUTI prevention strategies including aseptic insertion, catheter maintenance, antimicrobial UCs, and bladder bundle implementation. 30 studies were identified and summarised with interventions to prompt removal of UCs, with potential for inclusion in the meta-analyses. By meta-analysis (11 studies), the rate of CAUTI (episodes per 1000 catheter-days) was reduced by 53% (rate ratio 0.47; 95% CI 0.30 to 0.64, pSMD) in catheterisation duration (days) was -1.06 overall (p=0.065) including a statistically significant decrease in stop-order studies (SMD -0.37; pSMD, -1.54; p=0.071). No significant harm from catheter removal strategies is supported. Limited research is available regarding the impact of UC insertion and maintenance technique. A recent randomised controlled trial indicates antimicrobial catheters provide no significant benefit in preventing symptomatic CAUTIs. UC reminders and stop orders appear to reduce CAUTI rates and should be used to improve patient safety. Several evidence-based guidelines have evaluated CAUTI preventive strategies as well as emerging evidence regarding intervention bundles. Implementation strategies are important because reducing UC use involves changing well-established habits.

  9. Polymer multilayers loaded with antifungal β-peptides kill planktonic Candida albicans and reduce formation of fungal biofilms on the surfaces of flexible catheter tubes.

    Science.gov (United States)

    Raman, Namrata; Lee, Myung-Ryul; Palecek, Sean P; Lynn, David M

    2014-10-10

    Candida albicans is the most common fungal pathogen responsible for hospital-acquired infections. Most C. albicans infections are associated with the implantation of medical devices that act as points of entry for the pathogen and as substrates for the growth of fungal biofilms that are notoriously difficult to eliminate by systemic administration of conventional antifungal agents. In this study, we report a fill-and-purge approach to the layer-by-layer fabrication of biocompatible, nanoscale 'polyelectrolyte multilayers' (PEMs) on the luminal surfaces of flexible catheters, and an investigation of this platform for the localized, intraluminal release of a cationic β-peptide-based antifungal agent. We demonstrate that polyethylene catheter tubes with luminal surfaces coated with multilayers ~700nm thick fabricated from poly-l-glutamic acid (PGA) and poly-l-lysine (PLL) can be loaded, post-fabrication, by infusion with β-peptide, and that this approach promotes extended intraluminal release of this agent (over ~4months) when incubated in physiological media. The β-peptide remained potent against intraluminal inoculation of the catheters with C. albicans and substantially reduced the formation of C. albicans biofilms on the inner surfaces of film-coated catheters. Finally, we report that these β-peptide-loaded coatings exhibit antifungal activity under conditions that simulate intermittent catheter use and microbial challenge for at least three weeks. We conclude that β-peptide-loaded PEMs offer a novel and promising approach to kill C. albicans and prevent fungal biofilm formation on surfaces, with the potential to substantially reduce the incidence of device-associated infections in indwelling catheters. β-Peptides comprise a promising new class of antifungal agents that could help address problems associated with the use of conventional antifungal agents. The versatility of the layer-by-layer approach used here thus suggests additional opportunities to

  10. Dose requirements for UVC disinfection of catheter biofilms

    DEFF Research Database (Denmark)

    Bak, Jimmy; Ladefoged, Søren D.; Tvede, Michael

    2009-01-01

    Bacterial biofilms on permanent catheters are the major sources of infection. Exposure to ultraviolet-C (UVC) light has been proposed as a method for disinfecting the inner surface of catheters. Specification of a UVC-based device for in vivo disinfection is based on the knowledge of the required...... doses to kill catheter biofilm. Given these doses and the power of available UVC light sources, calculation of the necessary treatment times is then possible. To determine the required doses, contaminated urinary catheters were used as test samples and UVC treated in vitro. Patient catheters (n = 67......) were collected and cut into segments of equal size and treated with various UVC doses. After treatment, the biofilm was removed by scraping and quantified by counting colony forming units. Percentage killing rates were determined by calculating ratios between UVC-treated samples and controls (no UVC...

  11. Miniaturization of catheter systems for angiography

    International Nuclear Information System (INIS)

    Hawkins, I.F. Jr.; Akins, E.W.

    1988-01-01

    The authors discuss the use of small catheters and needles in angiography and interventional procedures to improve the quality of the procedures and increase the success rate and safety. This philosophy was initially poorly received, both by operators and by industry; however, more recently microtechniques have become more acceptable primarily because of the changing economic climate requiring procedures with shorter or no hospitalization time. Since 1970, the authors have performed well over 10,000 angiographic procedures using 5 French catheters, or smaller. During the last 12 years, they have used almost exclusively 4 French catheters, primarily with standard filming techniques which have resulted in no thrombosed arteries, or significant hematoma formation

  12. Cryoballoon Catheter Ablation in Atrial Fibrillation

    Directory of Open Access Journals (Sweden)

    Cevher Ozcan

    2011-01-01

    Full Text Available Pulmonary vein isolation with catheter ablation is an effective treatment in patients with symptomatic atrial fibrillation refractory or intolerant to antiarrhythmic medications. The cryoballoon catheter was recently approved for this procedure. In this paper, the basics of cryothermal energy ablation are reviewed including its ability of creating homogenous lesion formation, minimal destruction to surrounding vasculature, preserved tissue integrity, and lower risk of thrombus formation. Also summarized here are the publications describing the clinical experience with the cryoballoon catheter ablation in both paroxysmal and persistent atrial fibrillation, its safety and efficacy, and discussions on the technical aspect of the cryoballoon ablation procedure.

  13. Post-ruminal branched-chain amino acid supplementation and intravenous lipopolysaccharide infusion alters blood metabolites, rumen fermentation, and nitrogen balance of beef steers.

    Science.gov (United States)

    Löest, C A; Gilliam, G G; Waggoner, J W; Turner, J L

    2018-04-27

    Steers exposed to an endotoxin may require additional branched-chain AA (BCAA) to support an increase in synthesis of immune proteins. This study evaluated effects of bacterial lipopolysaccharide (LPS) and BCAA supplementation on blood metabolites and N balance of 20 ruminally-cannulated steers (177 ± 4.2 kg BW). The experiment was a randomized block design, with 14-d adaptation to metabolism stalls and diet (DM fed = 1.5% BW) and 6-d collection. Treatments were a 2 × 2 factorial of LPS (0 vs 1.0 to 1.5 μg/kg BW; -LPS vs +LPS) and BCAA (0 vs 35 g/d; -BCAA vs +BCAA). The LPS in 100 mL sterile saline was infused (1 mL/min via i.v. catheter) on d 15. The BCAA in an essential AA solution were abomasally infused (900 mL/d) 3 times daily in equal portions beginning on d 7. Blood, rumen fluid, and rectal temperature were collected on d 15 at h 0, 2, 4, 8, 12, and 24 after LPS infusion. Feces and urine were collected from d 16 to 20. Rectal temperatures were greater for +LPS vs. -LPS steers at 4 h and lower at 8 h after LPS infusion (LPS h, P BCAA than -BCAA steers at 12 h after LPS infusion (BCAA × h, P BCAA, P BCAA than -BCAA steers at 0 h and 24 h after LPS infusion (BCAA × h, P ≤ 0.05). Steers receiving +LPS had lower rumen pH at 8 h, greater total VFA at 8 h, and lower rumen NH3 at 24 h after LPS infusion compared with -LPS steers (LPS × h, P ≤ 0.04). Total tract passage rates, DM, OM, NDF, ADF, and N intake, fecal N, digested N, and retained N were lower (P BCAA vs -BCAA steers. The absence of LPS × BCAA interactions (P ≥ 0.20) for N balance indicated that post-ruminal supplementation of BCAA did not alleviate the negative effects of endotoxin on N utilization by growing steers.

  14. Single-shot pectoral plane (PECs I and PECs II) blocks versus continuous local anaesthetic infusion analgesia or both after non-ambulatory breast-cancer surgery: a prospective, randomised, double-blind trial.

    Science.gov (United States)

    O'Scanaill, P; Keane, S; Wall, V; Flood, G; Buggy, D J

    2018-04-01

    Pectoral plane blocks (PECs) are increasingly used in analgesia for patients undergoing breast surgery, and were recently found to be at least equivalent to single-shot paravertebral anaesthesia. However, there are no data comparing PECs with the popular practice of continuous local anaesthetic wound infusion (LA infusion) analgesia for breast surgery. Therefore, we compared the efficacy and safety of PECs blocks with LA infusion, or a combination of both in patients undergoing non-ambulatory breast-cancer surgery. This single-centre, prospective, randomised, double-blind trial analysed 45 women to receive either PECs blocks [levobupivacaine 0.25%, 10 ml PECs I and levobupivacaine 0.25%, 20 ml PECs II (PECs group); LA infusion catheter (levobupivacaine 0.1% at 10 ml h -1 for 24 h (LA infusion group); or both (PECs and LA infusion)]. The primary outcome measure was area under the curve of the pain verbal rating score whilst moving vs time (AUC) over 24 h. Secondary outcomes included total opioid consumption at 24 h. AUC moving was mean (SD) 71 (34) mm h -1 vs 58 (41) vs 23 (20) in PECs, LA infusion, and both, respectively; P=0.002. AUC at rest was also significantly lower in patients receiving both. The total 24 h opioid consumption [median (25-75%)] was 14 mg (9-26) vs 11 (8-24) vs 9 (5-11); P=0.4. No adverse events were observed. The combination of both pre-incisional PECs blocks and postoperative LA infusion provides better analgesia over 24 h than either technique alone after non-ambulatory breast-cancer surgery. NCT 03024697. Copyright © 2018 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.

  15. [Prevention of catheter-related infection: usefulness and cost-effectiveness of antiseptic catheters in children].

    Science.gov (United States)

    Lenz, Ana M; Vassallo, Juan C; Moreno, Guillermo E; Althabe, María; Gómez, Silvia; Magliola, Ricardo; Casimir, Lidia; Bologna, Rosa; Barretta, Jorge; Ruffa, Pablo

    2010-06-01

    To evaluate the cost-effectiveness of the antiseptic-impregnated catheter compared with conventional catheters in preventing catheter- related blood stream infections (CR-BSI). Cost-effectiveness analysis; clinical trial, experimental, randomized, controlled, prospective, open label. Patients and methods. A 172 patient cohort, under 1-year-old or less than 10 kg, postoperative cardiovascular children with central venous catheters (CVC) admitted to Cardiac Intensive Care Unit (UCI 35) at Hospital Nacional de Pediatría "Prof. Dr. Juan P. Garrahan", since September 2005 to December 2007. Demographic and CVC data were retrieved to compare: age, gender, weight, diagnosis, surgery, CVC days, costs and complications. Intervention. CVC Arrow, double-lumen, > 48 h of duration; intervention group: antiseptic-impregnated CVC vs. control group: CVC without antiseptics (conventional). The incidence of CR-IE (CR-Infected Events: colonization, local infection and/or CRBSI; combined end point) was 27% for antiseptic- impregnated CVC vs. 31% for conventional catheters (p= 0.6) with similar accumulated incidence of CR- BSI: 2.8 vs. 3.3 per 1000 dayscatheter. We found no differences between groups, except in weight: median 4.0 kg (r 2-17) vs. 4.7 kg (r 2-9) p= 0.0002 and age, median 2 months (r 1- 48) vs. 5 months (r 1- 24) p= 0.0019 in antiseptic-impregnated CVC group. These differences, though statistically significant were clinically non relevant. Median cost per patient during intensive care stay in the conventional CVC group was $3.417 (359-9.453) and in the antiseptic-impregnated-CVC group was $4.962 (239-24.532), p= 0.10. The use of antiseptic-impregnated CVC compared with conventional CVC did not decrease CR-BSI in this population. The cost per patients was higher in the antiseptic impregnated CVC group. These results do not support the routine use of this type of CVC in our population.

  16. Bronchial arterial infusion versus bronchial combined pulmonary arterial infusion for pulmonary metastatic tumors

    International Nuclear Information System (INIS)

    Dong Sheng; Dong Weihua; Jia Ningyang; Zhang Dianbo; Xiao Xiangsheng

    2008-01-01

    Objective: To evaluate the pulmonary metastatic tumor response to different ways of transcatheter arterial infusion. Methods: Thirty-five patients with pulmonary metastatic tumors were randomized divided into two groups: 15 patients with 49 lesions treated with bronchial arterial infusion (BAI) and 20 patients with 65 lesions treated with bronchial arterial infusion (BM)combined with pulmonary arterial infusion (PAI). The therapeutic response was assessed by the WHO evaluation criteria. Results: The total effective rate(CR + PR) of BAI was 65.3% (32/49), PAI + BAI was 61.5%(40/65) showing no statistical difference. The median survival time of BAI was 9 mo, BAI + PAI was 11.5 mo, demonstrating no statistical significance. Conclusions: BAI should be the primary treatment for pulmonary metastatic tumor. (authors)

  17. Patency of Femoral Tunneled Hemodialysis Catheters and Factors Predictive of Patency Failure

    International Nuclear Information System (INIS)

    Burton, Kirsteen R.; Guo, Lancia L. Q.; Tan, Kong T.; Simons, Martin E.; Sniderman, Kenneth W.; Kachura, John R.; Beecroft, John R.; Rajan, Dheeraj K.

    2012-01-01

    Purpose: To determine the patency rates of and factors associated with increased risk of patency failure in patients with femoral vein tunneled hemodialysis catheters. Methods: All femoral tunneled catheter insertions from 1996 to 2006 were reviewed, during which time 123 catheters were inserted. Of these, 66 were exchanges. Patients with femoral catheter failure versus those with femoral catheter patency were compared. Confounding factors, such as demographic and procedural factors, were incorporated and assessed using univariate and multivariable Cox proportional hazards regression analyses. Results: Mean catheter primary patency failure time was 96.3 days (SE 17.9 days). Primary patency at 30, 60, 90, and 180 days was 53.8%, 45.4%, 32.1%, and 27.1% respectively. Crude rates of risk of catheter failure did not suggest a benefit for patients receiving catheters introduced from one side versus the other, but more cephalad location of catheter tip was associated with improved patency. Multivariate analysis showed that patients whose catheters were on the left side (p = 0.009), were of increasing age at the time of insertion (p = 0.002) and that those who had diabetes (p = 0.001) were at significantly greater risk of catheter failure. The catheter infection rate was 1.4/1000 catheter days. Conclusion: Patients who were of a more advanced age and had diabetes were at greater risk of femoral catheter failure, whereas those who received femoral catheters from the right side were less at risk of catheter failure.

  18. Radiologically placed tunneled peritoneal catheter in palliation of malignant ascites

    International Nuclear Information System (INIS)

    Akinci, Devrim; Erol, Bekir; Ciftci, Tuerkmen T.; Akhan, Okan

    2011-01-01

    The purpose of this study was to evaluate retrospectively the safety and effectiveness of radiologically placed tunneled peritoneal catheter in palliation of malignant ascites. Between July 2005 and June 2009, 41 tunneled peritoneal catheters were placed under ultrasonographic and fluoroscopic guidance in 40 patients (mean age, 55 years; 22 women) who had symptomatic malignant ascites. No procedure related mortality was observed. Major complication occurred in one patient (2.5%) in the form of serious bacterial peritonitis that necessitated catheter removal. Minor complications such as minor bacterial peritonitis, catheter dislodgement, tunnel infection, and catheter blockage occurred in 11 patients (27.5%). The mean duration of survival after catheter placement was 11.8 weeks. All patients expired of their primary malignancies in the follow-up. Radiologically placed tunneled peritoneal catheter is safe and effective in palliation of symptomatic malignant ascites.

  19. Radiologically placed tunneled peritoneal catheter in palliation of malignant ascites

    Energy Technology Data Exchange (ETDEWEB)

    Akinci, Devrim; Erol, Bekir; Ciftci, Tuerkmen T. [Hacettepe University, Faculty of Medicine, Department of Radiology, 06100 Ankara (Turkey); Akhan, Okan, E-mail: akhano@tr.net [Hacettepe University, Faculty of Medicine, Department of Radiology, 06100 Ankara (Turkey)

    2011-11-15

    The purpose of this study was to evaluate retrospectively the safety and effectiveness of radiologically placed tunneled peritoneal catheter in palliation of malignant ascites. Between July 2005 and June 2009, 41 tunneled peritoneal catheters were placed under ultrasonographic and fluoroscopic guidance in 40 patients (mean age, 55 years; 22 women) who had symptomatic malignant ascites. No procedure related mortality was observed. Major complication occurred in one patient (2.5%) in the form of serious bacterial peritonitis that necessitated catheter removal. Minor complications such as minor bacterial peritonitis, catheter dislodgement, tunnel infection, and catheter blockage occurred in 11 patients (27.5%). The mean duration of survival after catheter placement was 11.8 weeks. All patients expired of their primary malignancies in the follow-up. Radiologically placed tunneled peritoneal catheter is safe and effective in palliation of symptomatic malignant ascites.

  20. Where does the pulmonary artery catheter float: Transesophageal echocardiography evaluation

    Directory of Open Access Journals (Sweden)

    Deepak K Tempe

    2015-01-01

    Full Text Available Background: Pulmonary artery (PA catheter provides a variety of cardiac and hemodynamic parameters. In majority of the patients, the catheter tends to float in the right pulmonary artery (RPA than the left pulmonary artery (LPA. We evaluated the location of PA catheter with the help of transesophageal echocardiography (TEE to know the incidence of its localization. Three views were utilized for this purpose; midesophageal ascending aorta (AA short-axis view, modified mid esophageal aortic valve long-axis view, and modified bicaval view. Methods: We enrolled 135 patients undergoing elective cardiac surgery where both the PA catheter and TEE were to be used; for this prospective observational study. PA catheter was visualized by TEE in the above mentioned views and the degree of clarity of visualization by three views was also noted. Position of the PA catheter was further confirmed by a postoperative chest radiograph. Results: One patient was excluded from the data analysis. PA catheter was visualized in RPA in 129 patients (96% and in LPA in 4 patients (3%. In 1 patient, the catheter was visualized in main PA in the chest radiograph. The midesophageal AA short-axis, modified aortic valve long-axis, and modified bicaval view provided good visualization in 51.45%, 57.4%, and 62.3% patients respectively. Taken together, PA catheter visualization was good in 128 (95.5% patients. Conclusion: We conclude that the PA catheter has a high probability of entering the RPA as compared to LPA (96% vs. 3% and TEE provides good visualization of the catheter in RPA.

  1. Comparison of continuous interscalene block and subacromial infusion of local anesthetic for postoperative analgesia after open shoulder surgery.

    Science.gov (United States)

    Baskan, Semih; Cankaya, Deniz; Unal, Hidayet; Yoldas, Burak; Taspinar, Vildan; Deveci, Alper; Tabak, Yalcin; Baydar, Mustafa

    2017-01-01

    This study compared the efficacy of continuous interscalene block (CISB) and subacromial infusion of local anesthetic (CSIA) for postoperative analgesia after open shoulder surgery. This randomized, prospective, double-blinded, single-center study included 40 adult patients undergoing open shoulder surgery. All patients received a standardized general anesthetic. The patients were separated into group CISB and group CSIA. A loading dose of 40 mL 0.25% bupivacaine was administered and patient-controlled analgesia was applied by catheter with 0.1% bupivacaine 5 mL/h throughout 24 h basal infusion, 2 mL bolus dose, and 20 min knocked time in both groups postoperatively. Visual analog scale (VAS) scores, additional analgesia need, local anesthetic consumption, complications, and side effects were recorded during the first 24 h postoperatively. The range of motion (ROM) score was recorded preoperatively and in the first and third weeks postoperatively. A statistically significant difference was determined between the groups in respect of consumption of local anesthetic, VAS scores, additional analgesia consumption, complications, and side effects, with lower values recorded in the CISB group. There were no significant differences in ROM scoring in the preoperative and postoperative third week between the two groups but there were significant differences in ROM scoring in the postoperative first week, with higher ROM scoring values in the group CISB patients. The results of this study have shown that continuous interscalene infusion of bupivacaine is an effective and safe method of postoperative analgesia after open shoulder surgery.

  2. Central venous catheters: the role of radiology

    International Nuclear Information System (INIS)

    Tan, P.L.; Gibson, M.

    2006-01-01

    The insertion and management of long-term venous catheters have long been the province of anaesthetists, intensive care physicians and surgeons. Radiologists are taking an increasing role in the insertion of central venous catheters (CVCs) because of their familiarity with the imaging equipment and their ability to manipulate catheters and guide-wires. The radiological management of the complications of CVCs has also expanded as a result. This article reviews the role of radiology in central venous access, covering the detection and management of their complications

  3. Magnetic catheter manipulation in the interventional MR imaging environment.

    Science.gov (United States)

    Wilson, Mark W; Martin, Alastair B; Lillaney, Prasheel; Losey, Aaron D; Yee, Erin J; Bernhardt, Anthony; Malba, Vincent; Evans, Lee; Sincic, Ryan; Saeed, Maythem; Arenson, Ronald L; Hetts, Steven W

    2013-06-01

    To evaluate deflection capability of a prototype endovascular catheter, which is remotely magnetically steerable, for use in the interventional magnetic resonance (MR) imaging environment. Copper coils were mounted on the tips of commercially available 2.3-3.0-F microcatheters. The coils were fabricated in a novel manner by plasma vapor deposition of a copper layer followed by laser lithography of the layer into coils. Orthogonal helical (ie, solenoid) and saddle-shaped (ie, Helmholtz) coils were mounted on a single catheter tip. Microcatheters were tested in water bath phantoms in a 1.5-T clinical MR scanner, with variable simultaneous currents applied to the coils. Catheter tip deflection was imaged in the axial plane by using a "real-time" steady-state free precession MR imaging sequence. Degree of deflection and catheter tip orientation were measured for each current application. The catheter tip was clearly visible in the longitudinal and axial planes. Magnetic field artifacts were visible when the orthogonal coils at the catheter tip were energized. Variable amounts of current applied to a single coil demonstrated consistent catheter deflection in all water bath experiments. Changing current polarity reversed the observed direction of deflection, whereas current applied to two different coils resulted in deflection represented by the composite vector of individual coil activations. Microcatheter navigation through the vascular phantom was successful through control of applied current to one or more coils. Controlled catheter deflection is possible with laser lithographed multiaxis coil-tipped catheters in the MR imaging environment. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.

  4. Positioning of nasobiliary tube using magnet-loaded catheters.

    Science.gov (United States)

    Watanabe, Seitaro; Sato, Takamitsu; Kato, Shingo; Hosono, Kunihiro; Kobayashi, Noritoshi; Nakajima, Atsushi; Kubota, Kensuke

    2013-10-01

    In endoscopic nasobiliary drainage (ENBD), repositioning the catheter from the mouth to the nose is complicated. We devised a method using catheters with magnets and verified its utility and safety. We prospectively enrolled 20 patients undergoing ENBD at Yokohama City University Hospital. The procedures were successful in all 20 cases and no case required a change of operators to a senior doctor. The mean time for the procedure was 36.6 seconds. The emetic reflex was induced 0.5 times on average using the magnet method. The mean X-ray exposure time was 29.6 seconds. No complications occurred. The magnet-loaded catheter method for positioning the ENBD catheter before finally leading it through the nose took little time and was performed successfully and safely. Therefore, the magnet method could become the first choice among techniques for ENBD catheter placement. © Georg Thieme Verlag KG Stuttgart · New York.

  5. UVC fluencies for preventative treatment of Pseudomonas aeruginosa contaminated polymer tubes

    DEFF Research Database (Denmark)

    Bak, Jimmy; Ladefoged, Søren D; Begovic, Tanja

    2010-01-01

    Exposing Pseudomonas aeruginosa biofilm grown on the inner surface of Teflon and silicone tubes to UVC light (265 nm) from light emitting diodes (LED) has previously been shown to substantially reduce biofilm growth. Smaller UVC fluencies were required to disinfect Teflon tubes compared to silicone...... tubes. Light propagation enhancement in tubes can be obtained if the refractive index of the intra-luminal saline solution is higher than that of the polymer. This condition is achieved by using Teflon tubes with a low refractive index (1.34) instead of the polymers with a high refractive index (1...... is demonstrated to be a preventative disinfection treatment on tubes made of Teflon, which enhances the UVC light propagation, and on tubes made of a softer material, ethylene vinyl acetate (EVA), which is suitable for catheters but much less suitable for UVC light propagation. Simulating an aseptic breach (~10...

  6. Disinfection of Pseudomonas aeruginosa biofilm contaminated tube lumens with ultraviolet C light emitting diodes

    DEFF Research Database (Denmark)

    Bak, Jimmy; Ladefoged, Søren D; Tvede, Michael

    2010-01-01

    with biofilm was investigated. It was shown that UVC light propagation was possible through both Teflon and catheter tubes (silicone). The disinfection efficiency of the diodes was demonstrated on tubes contaminated artificially with a Pseudomonas aeruginosa biofilm. The tubes were connected to a flow system...... and biofilms were produced during a 3 day period. Tubes in lengths of 10 (Teflon, silicone) and 20 cm (Teflon) were contaminated. Tubes for control and for UVC treatment were contaminated in parallel. Biofilms were sampled from the total inner surface of the tubes. Colony counts on the control samples were...... in the range of 5 x 10(5)-1.3 x 10(9) CFU ml(-1), with disinfection rates in the range 96-100%. The applied UVC doses corresponded to treatment times between 15 and 300 min. Disinfection (100%) was obtained in 10 cm Teflon tubes exposed for 30 min (detection limit...

  7. Disinfection of Pseudomonas aeruginosa biofilm contaminated tube lumens with ultraviolet C light emitting diodes

    DEFF Research Database (Denmark)

    Bak, Jimmy; Ladefoged, S.D.; Tvede, M.

    2010-01-01

    with biofilm was investigated. It was shown that UVC light propagation was possible through both Teflon and catheter tubes ( silicone). The disinfection efficiency of the diodes was demonstrated on tubes contaminated artificially with a Pseudomonas aeruginosa biofilm. The tubes were connected to a flow system...... and biofilms were produced during a 3 day period. Tubes in lengths of 10 ( Teflon, silicone) and 20 cm ( Teflon) were contaminated. Tubes for control and for UVC treatment were contaminated in parallel. Biofilms were sampled from the total inner surface of the tubes. Colony counts on the control samples were...... in the range of 5 x 10(5)-1.3 x 10(9) CFU ml(-1), with disinfection rates in the range 96-100%. The applied UVC doses corresponded to treatment times between 15 and 300 min. Disinfection (100%) was obtained in 10 cm Teflon tubes exposed for 30 min (detection limit...

  8. Intravascular catheter related infections in children admitted on the ...

    African Journals Online (AJOL)

    peripheral venous intravascular catheters uncoated with no antibiotic or antiseptic, was done. Social demographic characteristics, anthropometry, clinical examination including the catheter site were determined at enrollment. The children had their blood, catheter tip and hub samples taken off for culture and sensitivity as ...

  9. Technical note: Measurement of mammary plasma flow in sows by downstream dilution of mammary vein infused para-aminohippuric acid

    DEFF Research Database (Denmark)

    Larsen, Uffe Krogh; Storm, Adam Christian; Theil, Peter Kappel

    2016-01-01

    catheter was surgically implanted in the femoral artery, and another 2 were inserted in the right cranial mammary vein of 8 second- and third-parity sows on d 76 ± 2 SEM of gestation. On the 3rd and 17th days in milk, arterial and venous blood samples were drawn in hourly intervals from 0.5 h before until...... 6.5 h after feeding. The MPF in the right cranial mammary vein was measured by downstream dilution of infused pAH (3.0 mmol/h). Total MPF-pAH was calculated assuming that the measured flow constituted the flow from 5 out of 14 suckled glands on the basis of the anatomical structure of the mammary...

  10. The importance of effective catheter securement.

    Science.gov (United States)

    Fisher, Jayne

    This article examines the importance of securing/fixing indwelling urinary catheters. The Oxford English dictionary interlinks the two words-'secure' and 'fix'-as having the same meaning. To secure the catheter should not be confused with 'support', whereby the weight of the urine drainage bag is supported with the use of velcro straps or a sleeve. The author introduces the need for the concept of this practice to be at the forefront of nurses' minds in all settings, and this is demonstrated through the use of case studies. Current guidance in this area is reviewed, as well as the problems that can arise when catheters are not secured properly and the available products for health professionals to use.

  11. Efficacy of a one-catheter concept for transradial coronary angiography.

    Directory of Open Access Journals (Sweden)

    Christoph Langer

    Full Text Available Transradial coronary angiography (TRC can be performed with a one-catheter approach for the right and left coronary ostium (R/LCO. We investigated the performance of a special diagnostic catheter widely used for the one-catheter-approach, the Tiger (Tiger II, TerumoTM.In a dual center registry we analyzed 1412 TRC-procedures exclusively performed by experienced TRC-operators. We compared the performance of the Tiger with Judkins catheters by retrospectively judging ostial catheter stability during contrast injection, and by measuring contrast use, fluoroscopy time (FT and complication rate.Poor or failed ostial engagement was found in 40.5% in the Tiger group, compared to 46.6% with the use of Judkins catheters (p<0.183. Ostial instability of the Tiger was found more often during engagement of the LCO than the RCO (34.4% vs. 10.8%, p<0.001, whereas it was similar in the LCO and RCO for Judkins catheters (27.4% vs. 26.7%, p = 0.840. TRC-procedures performed with Tiger catheters were associated with less contrast volume (63.48 ± 29.83mL vs. 82.51 ± 56.58mL, p<0.004 and shorter FT than with Judkins catheters. (198.27 ± 194.8sec vs. 326.85 ± 329.70sec. Forearm hematomas occurred less often with the Tiger (1.2% vs. 6.6%, p< 0.02.The Tiger employed as a single catheter in TRC is an effective tool to achieve lower contrast volume and fluoroscopy time at a low complication rate. Unstable engagement affects predominantly the left coronary artery, but its overall frequency is similar for both, the Tiger and Judkins catheters.

  12. pH dependence of the kinetics of interfacial tension changes during protein adsorption from sessile droplets on FEP-Teflon

    NARCIS (Netherlands)

    VanderVegt, W; Norde, W; VanderMei, HC; Busscher, HJ

    Interfacial tension changes during protein adsorption at both the solid-liquid and the liquid-vapor interface were measured simultaneously by ADSA-P from sessile droplets of protein solutions on fluoroethylenepropylene-Teflon. Four globular proteins of similar size, viz. lysozyme, ribonuclease,

  13. Preparation of membranes by radiation grafting of acrylic acid onto Teflon-FEP film

    International Nuclear Information System (INIS)

    Gupta, B.D.

    1991-01-01

    The grafting of acrylic acid on radiation-peroxidised Teflon-FEP film provides an effective technique to prepare ion-exchange membranes. It was found that the grafted membranes have very high degree of swelling in aqueous KOH. The electric resistance of the film decreases considerably by grafting. An electric resistance of 0.2Ω cm 2 was obtained for a graft level beyond 58%. The hydrophilicity of the film was evaluated in terms of contact angle which shows a decreasing trend with the increasing degree of grafting. (author). 8 refs

  14. Investigation of beta ray attenuation in CaSO4:Dy(Tm)-teflon rods

    International Nuclear Information System (INIS)

    Szabo, P.P.

    1990-12-01

    Ultrathin discs were prepared from CaSO 4 :Dy(Tm)-teflon rods by cutting them with a microtom. The effect of cutting was studied experimentally. It was found that the cutting does not affect the TL signal of the discs, so one will be able to irradiate the rod and cut it afterwards which means that this method can be applied in the dosimetry of boundaries or to establish the energy of beta radiation. Depth dose distribution measurements were carried out by irradiating the rods with beta sources. (K.A.) 5 refs.; 6 figs

  15. Pseudoaneurysm embolization and vasopressin infusion for lower gastrointestinal bleeding due to recurrence of urinary bladder carcinoma.

    Science.gov (United States)

    Kakizawa, Hideaki; Toyota, Naoyuki; Mita, Koji; Fujimura, Yoshio; Hieda, Masashi; Hirai, Nobuhiko; Tachikake, Toshihiro; Ito, Katsuhide

    2006-05-01

    We report a case that was successfully treated for massive lower gastrointestinal (LGI) bleeding due to a recurrent urinary bladder carcinoma. Treatment consisted of combination therapy including embolization of an inferior gluteal artery (IGA) pseudoaneurysm and low-dose arterial vasopressin infusion via a sigmoid artery (SA). A 57-year-old man presented with life-threatening sudden, massive LGI bleeding due to an obturator lymph node (LN) metastasis from a urinary bladder carcinoma. Computed tomography showed that the LN recurrence had invaded all the way to the sigmoid colon, and there was a pseudoaneurysm with extravasation inside the recurrence. An angiogram revealed a left IGA pseudoaneurysm. We therefore excluded the pseudoaneurysm by embolization with microcoils. Following this treatment the bleeding decreased, but intermittent LGI bleeding continued. Endoscopic examination showed the tumor with a huge ulcer inside the colonic lumen, and continuous oozing was confirmed. A second angiogram showed no recurrence of the IGA pseudoaneurysm and no apparent findings of bleeding. Then a 3F microcatheter was placed in the SA selectively using a coaxial catheter system, and vasopressin was infused at a rate 0.05 U/min for 12 h. Bleeding completely ceased 2 days later. There were no signs of ischemic gastrointestinal complications. Massive LGI bleeding has not recurred in 5 months.

  16. Acute effects of the glucagon-like peptide-1 receptor agonist, exenatide, on blood pressure and heart rate responses to intraduodenal glucose infusion in type 2 diabetes.

    Science.gov (United States)

    Thazhath, Sony S; Marathe, Chinmay S; Wu, Tongzhi; Chang, Jessica; Khoo, Joan; Kuo, Paul; Checklin, Helen L; Bound, Michelle J; Rigda, Rachael S; Horowitz, Michael; Jones, Karen L; Rayner, Christopher K

    2017-01-01

    To evaluate the effects of the glucagon-like peptide-1 receptor agonist, exenatide, on blood pressure and heart rate during an intraduodenal glucose infusion in type 2 diabetes. Nine subjects with type 2 diabetes were randomised to receive intravenous exenatide or saline control in a crossover design. Glucose (3 kcal min -1 ) was infused via an intraduodenal manometry catheter for 60 min. Blood pressure, heart rate, and the frequency and amplitude of duodenal pressure waves were measured at regular intervals. Gastrointestinal symptoms were monitored using 100 mm visual analogue scales. During intraduodenal glucose infusion (0-60 min), diastolic (p (0-60)  = 0.03) and mean arterial (p (0-60)  = 0.03) blood pressures and heart rate (p (0-60)  = 0.06; p (0-120)  = 0.03)) were higher with exenatide compared to placebo. The increase in the area under the curve for diastolic blood pressure and mean arterial blood pressure was related directly to the suppression of the duodenal motility index with exenatide compared to control (p = 0.007 and 0.04, respectively). In type 2 diabetes, intravenous exenatide increases mean arterial blood pressure and heart rate during an intraduodenal glucose infusion, supporting the need for further research with exenatide for its potential use in postprandial hypotension. © The Author(s) 2016.

  17. Hippocampal infusions of glucose reverse memory deficits produced by co-infusions of a GABA receptor agonist.

    Science.gov (United States)

    Krebs-Kraft, Desiree L; Parent, Marise B

    2008-02-01

    Although septal infusions of glucose typically have positive effects on memory, we have shown repeatedly that this treatment exacerbates memory deficits produced by co-infusions of gamma-aminobutyric acid (GABA) receptor agonists. The present experiments tested whether this negative interaction between glucose and GABA in the medial septum would be observed in the hippocampus, a brain region where glucose typically has positive effects on memory. Specifically, we determined whether hippocampal infusions of glucose would reverse or exacerbate memory deficits produced by hippocampal co-infusions of the GABA receptor agonist muscimol. Fifteen minutes prior to either assessing spontaneous alternation (SA) or continuous multiple trial inhibitory avoidance (CMIA) training, male Sprague-Dawley-derived rats were given bilateral hippocampal infusions of vehicle (phosphate-buffered saline [PBS], 1 microl/2 min), glucose (33 or 50 nmol), muscimol (0.3 or 0.4 microg, SA or 3 microg, CMIA) or muscimol and glucose combined in one solution. The results indicated that hippocampal infusions of muscimol alone decreased SA scores and CMIA retention latencies. More importantly, hippocampal infusions of glucose, at doses that had no effect when infused alone, attenuated (33 nmol) or reversed (50 nmol) the muscimol-induced memory deficits. Thus, although co-infusions of glucose with muscimol into the medial septum impair memory, the present findings show that an opposite effect is observed in the hippocampus. Collectively, these findings suggest that the memory-impairing interaction between glucose and GABA in the medial septum is not a general property of the brain, but rather is brain region-dependent.

  18. Subcutaneous infusion in palliative care: a focus on the neria soft 90 infusion set.

    Science.gov (United States)

    Gabriel, Janice

    2014-11-01

    Subcutaneous administration of medications and/or fluids can play a crucial part in supporting patients at home and thereby avoiding the need for hospitalisation. It is an area of patient care that has received little attention compared with other types of parenteral therapies. However, it is an effective and safe route for continuous administration for individuals requiring palliative care. Technological advancements have led to improved subcutaneous infusion devices, such as fine-gauge cannulae with integral sharps protection, as well as integral hypoallergenic dressings. These design features not only help to increase patient comfort but also minimise the potential for needlestick injuries, as well as providing the health professional with one sterile package containing all of the components needed to establish subcutaneous infusion. However, technological developments alone are insufficient to improve patient outcomes. Knowledge of the individual patient, together with their diagnosis and intended treatment, will influence the choice of subcutaneous infusion device, with the overall aim of minimising the potential for complications and improving comfort. This paper provides an overview of subcutaneous infusion, including the importance of patient assessment and the education and training needs of health professionals, and then focuses on one specific subcutaneous infusion device: the neria soft 90 infusion set.

  19. Feedforward Coordinate Control of a Robotic Cell Injection Catheter.

    Science.gov (United States)

    Cheng, Weyland; Law, Peter K

    2017-08-01

    Remote and robotically actuated catheters are the stepping-stones toward autonomous catheters, where complex intravascular procedures may be performed with minimal intervention from a physician. This article proposes a concept for the positional, feedforward control of a robotically actuated cell injection catheter used for the injection of myogenic or undifferentiated stem cells into the myocardial infarct boundary zones of the left ventricle. The prototype for the catheter system was built upon a needle-based catheter with a single degree of deflection, a 3-D printed handle combined with actuators, and the Arduino microcontroller platform. A bench setup was used to mimic a left ventricle catheter procedure starting from the femoral artery. Using Matlab and the open-source video modeling tool Tracker, the planar coordinates ( y, z) of the catheter position were analyzed, and a feedforward control system was developed based on empirical models. Using the Student's t test with a sample size of 26, it was determined that for both the y- and z-axes, the mean discrepancy between the calibrated and theoretical coordinate values had no significant difference compared to the hypothetical value of µ = 0. The root mean square error of the calibrated coordinates also showed an 88% improvement in the z-axis and 31% improvement in the y-axis compared to the unmodified trial run. This proof of concept investigation leads to the possibility of further developing a feedfoward control system in vivo using catheters with omnidirectional deflection. Feedforward positional control allows for more flexibility in the design of an automated catheter system where problems such as systemic time delay may be a hindrance in instances requiring an immediate reaction.

  20. An intervention to improve the catheter associated urinary tract infection rate in a medical intensive care unit: Direct observation of catheter insertion procedure.

    Science.gov (United States)

    Galiczewski, Janet M; Shurpin, Kathleen M

    2017-06-01

    Healthcare associated infections from indwelling urinary catheters lead to increased patient morbidity and mortality. The purpose of this study was to determine if direct observation of the urinary catheter insertion procedure, as compared to the standard process, decreased catheter utilization and urinary tract infection rates. This case control study was conducted in a medical intensive care unit. During phase I, a retrospective data review was conducted on utilsiation and urinary catheter infection rates when practitioners followed the institution's standard insertion algorithm. During phase II, an intervention of direct observation was added to the standard insertion procedure. The results demonstrated no change in utilization rates, however, CAUTI rates decreased from 2.24 to 0 per 1000 catheter days. The findings from this study may promote changes in clinical practice guidelines leading to a reduction in urinary catheter utilization and infection rates and improved patient outcomes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Femoral venous catheters: a safe alternative for delivering parenteral alimentation.

    Science.gov (United States)

    Friedman, B; Kanter, G; Titus, D

    1994-04-01

    Femoral vein catheterization is an alternative method of obtaining central venous access. Placement of femoral venous catheters (FVCs) is possible in the majority of patients, suitable for most indications, and associated with a low complication rate during insertion. We wished to determine the incidence of infections or other complications resulting when parenteral nutrition was delivered through FVCs. Fifty-two patients were followed from a hospital-wide population including patients in the critical care units. Triple-lumen catheters were placed by using the sterile Seldinger technique, and sites were examined daily for inflammation. Bacteriologic surveillance was accomplished by submitting the catheter tip for semiquantitative cultures. If catheter line sepsis was suspected, blood samples for cultures were drawn through the catheter and peripherally. The rate of occurrence of colonized catheters was 9.6% (five of 52), and catheter sepsis was found in one case (1.9%). Other than inflammation at six (11.5%) of 52 catheter sites, noninfectious complications of FVCs were not found. On the basis of these findings, we consider FVC-delivered parenteral alimentation a safe and effective alternative to other forms of central venous access.

  2. Intrathecal Catheterization and Drug Delivery in Guinea Pigs: A Small-animal Model for Morphine-evoked Granuloma Formation.

    Science.gov (United States)

    Eddinger, Kelly A; Rondon, Eric S; Shubayev, Veronica I; Grafe, Marjorie R; Scadeng, Miriam; Hildebrand, Keith R; Page, Linda M; Malkmus, Shelle A; Steinauer, Joanne J; Yaksh, Tony L

    2016-08-01

    Intrathecal infusion of opioids in dogs, sheep, and humans produces local space-occupying masses. To develop a small-animal model, the authors examined effects of intrathecal catheterization and morphine infusion in guinea pigs. Under isoflurane, polyethylene or polyurethane catheters were advanced from the cisterna magna to the lumbar enlargement. Drugs were delivered as a bolus through the externalized catheter or continuously by subcutaneous minipumps. Hind paw withdrawal to a thermal stimulus was assessed. Spinal histopathology was systematically assessed in a blinded fashion. To assist in determining catheter placement, ex vivo images were obtained using magnetic resonance imaging in several animals. Canine spinal tissue from previous intrathecal morphine studies was analyzed in parallel. (1) Polyethylene (n = 30) and polyurethane (n = 25) catheters were implanted in the lumbar intrathecal space. (2) Bolus intrathecal morphine produced a dose-dependent (20 to 40 μg/10 μl) increase in thermal escape latencies. (3) Absent infusion, a catheter-associated distortion of the spinal cord and a fibrotic investment were noted along the catheter tract (polyethylene > polyurethane). (4) Intrathecal morphine infusion (25 mg/ml/0.5 μl/h for 14 days) resulted in intrathecal masses (fibroblasts, interspersed collagen, lymphocytes, and macrophages) arising from meninges proximal to the catheter tip in both polyethylene- and polyurethane-catheterized animals. This closely resembles mass histopathology from intrathecal morphine canine studies. Continuous intrathecal infusion of morphine leads to pericatheter masses that morphologically resemble those observed in dogs and humans. This small-animal model may be useful for studying spinal drug toxicology in general and the biology of intrathecal granuloma formation in particular.

  3. Totally implantable venous catheters for chemotherapy: experience in 500 patients

    Directory of Open Access Journals (Sweden)

    Nelson Wolosker

    Full Text Available CONTEXT: Totally implantable devices are increasingly being utilized for chemotherapy treatment of oncological patients, although few studies have been done in our environment to analyze the results obtained from the implantation and utilization of such catheters. OBJECTIVE: To study the results obtained from the implantation of totally implantable catheters in patients submitted to chemotherapy. TYPE OF STUDY: Prospective. SETTING: Hospital do Câncer A.C. Camargo, São Paulo, Brazil. METHODS: 519 totally implantable catheters were placed in 500 patients submitted to chemotherapy, with preference for the use of the right external jugular vein. Evaluations were made of the early and late-stage complications and patient evolution until removal of the device, death or the end of the treatment. RESULTS: The prospective analysis showed an average duration of 353 days for the catheters. There were 427 (82.2% catheters with no complications. Among the early complications observed, there were 15 pathway hematomas, 8 cases of thrombophlebitis of the distal stump of the external jugular vein and one case of pocket infection. Among the late-stage complications observed, there were 43 infectious complications (0.23/1000 days of catheter use, 11 obstructions (0.06/1000 days of catheter use and 14 cases of deep vein thrombosis (0.07/1000 days of catheter use. Removal of 101 catheters was performed: 35 due to complications and 66 upon terminating the treatment. A total of 240 patients died while the catheter was functioning and 178 patients are still making use of the catheter. CONCLUSION: The low rate of complications obtained in this study confirms the safety and convenience of the use of totally implantable accesses in patients undergoing prolonged chemotherapy regimes.

  4. Monorail Piccolino catheter: a new rapid exchange/ultralow profile coronary angioplasty system.

    Science.gov (United States)

    Mooney, M R; Douglas, J S; Mooney, J F; Madison, J D; Brandenburg, R O; Fernald, R; Van Tassel, R A

    1990-06-01

    The Monorail Piccolino coronary angioplasty balloon catheter (MBC) was evaluated on 118 patients at two centers. Technical success was achieved in 110 patients (93%). Time for catheter exchange and total fluoroscopy time were significantly lower for the Monorail catheter than with standard equipment (exchange time 97 vs. 170 seconds P less than .05 and fluoroscopy time 17 vs. 88 seconds P less than .001). The advantages of rapid exchange and the ability of utilize 2 Monorail balloon catheters through one 9F guiding catheter for simultaneous inflations allowed for maximal flexibility in treating patients with bifurcation lesions. The double wire approach utilizing one Monorail balloon catheter with a 7F guiding catheter was also technically successful. The Monorail Piccolino balloon catheter has unique features that allow for greater ease of operator use, rapid catheter exchange, and optimal angiographic visualization. It is felt that this catheter design provides distinct advantages over standard angioplasty equipment.

  5. Radiographic signs of non-venous placement of intended central venous catheters in children

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Erin C. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Taylor, George A. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Harvard Medical School, Department of Radiology, Boston, MA (United States)

    2016-02-15

    Central venous catheters (CVCs) are commonly used in children, and inadvertent arterial or extravascular cannulation is rare but has potentially serious complications. To identify the radiographic signs of arterial placement of CVCs. We retrospectively reviewed seven cases of arterially malpositioned CVCs on chest radiograph. These cases were identified through departmental quality-assurance mechanisms and external consultation. Comparison of arterial cases was made with 127 age-matched chest radiographs with CVCs in normal, expected venous location. On each anteroposterior (AP) radiograph we measured the distance of the catheter tip from the right lateral border of the thoracic spine, and the angle of the vertical portion of the catheter relative to the midline. On each lateral radiograph we measured the angle of the vertical portion of each catheter relative to the anterior border of the thoracic spine. When bilateral subclavian catheters were present, the catheter tips were described as crossed, overlapping or uncrossed. On AP radiographs, arterially placed CVCs were more curved to the left, with catheter tip positions located farther to the left of midline than normal venous CVCs. When bilateral, properly placed venous catheters were present, all catheters crossed at the level of the superior vena cava (SVC). When one of the bilateral catheters was in arterial position, neither of the catheters crossed or the inter-catheter crossover distance was exaggerated. On lateral radiographs, there was a marked anterior angulation of the vertical portion of the catheter (mean angle 37 ± 15 standard deviation [SD] in arterial catheters versus 5.9 ± 8.3 SD in normally placed venous catheters). Useful radiographic signs suggestive of unintentional arterial misplacement of vascular catheters include leftward curvature of the vertical portion of the catheter, left-side catheter tip position, lack of catheter crossover on the frontal radiograph, as well as exaggerated

  6. Catheter-Related Sepsis Due to Rhodotorula glutinis

    Science.gov (United States)

    Hsueh, Po-Ren; Teng, Lee-Jene; Ho, Shen-Wu; Luh, Kwen-Tay

    2003-01-01

    We describe a central venous catheter-related (Port-A-Cath; Smiths Industries Medical Systems [SIMS] Deltec, Inc., St. Paul, Minn.) infection caused by Rhodotorula glutinis in a 51-year-old man with nasopharyngeal carcinoma. He was treated with fluconazole for 8 weeks and had the catheter removed. Two isolates of R. glutinis recovered from blood specimens (one obtained via peripheral veins and one via the catheter) before administration of fluconazole and one recovered from the removed catheter 17 days after initiation of fluconazole therapy exhibited high-level resistance to fluconazole (MICs, >256 μg/ml). These three isolates were found to belong to a single clone on the basis of identical antibiotypes determined by the E test (PDM Epsilometer; AB Biodisk, Solna, Sweden) and biotypes determined by API ID32 C (bioMerieux, Marcy I'Etoile, France) and their identical random amplified polymorphic DNA patterns. PMID:12574300

  7. Knee strength retention and analgesia with continuous perineural fentanyl infusion after total knee replacement: randomized controlled trial.

    Science.gov (United States)

    Mangar, Devanand; Karlnoski, Rachel A; Sprenker, Collin J; Downes, Katheryne L; Taffe, Narrene; Wainwright, Robert; Gustke, Kenneth; Bernasek, Thomas L; Camporesi, Enrico

    2014-04-01

    Despite providing adequate pain relief, a femoral nerve block can induce postoperative muscle weakness after total knee arthoplasty (TKA). Fentanyl has been shown to have peripheral effects but has not been used as a perineural infusate alone after TKA. Sixty patients scheduled for TKA were randomized to one of three blinded groups: a continuous 24 h infusion of either fentanyl 3 μg/ml, ropivacaine 0.1%, or 0.9% normal saline through a femoral nerve sheath catheter at 10 ml/h. The main outcome was maximum voluntary isometric contraction (MVIC) in the quadriceps femoris (knee extension), measured by a handheld dynamometer (Nm/kg). Other variables assessed were preoperative and postoperative visual analog scale (VAS) scores, hamstrings MVIC (knee flexion), active range of motion of the operative knee, distance ambulated, incidence of knee buckling, supplemental morphine usage, postoperative side effects, and serum fentanyl levels. Quadriceps MVIC values were significantly greater in the fentanyl group compared to the group that received ropivacaine (median values, 0.08 vs. 0.03 Nm/kg; p = 0.028). The incidence of postoperative knee buckling upon ambulation was higher in the ropivacaine group compared to the fentanyl group, although not statistically significant (40% vs. 15 %, respectively; p = 0.077). VAS scores while ambulating were not significantly different between the fentanyl group and the ropivacaine group (p = 0.270). Postoperative morphine consumption, nausea and vomiting, and resting VAS scores were similar among the three groups. A continuous perineural infusion of fentanyl produced greater strength retention than ropivacaine post-TKA.

  8. Use of asymmetric bidirectional catheters with different curvature radius for catheter ablation of cardiac arrhythmias.

    Science.gov (United States)

    Mantziari, Lilian; Suman-Horduna, Irina; Gujic, Marko; Jones, David G; Wong, Tom; Markides, Vias; Foran, John P; Ernst, Sabine

    2013-06-01

    The impact of recently introduced asymmetric bidirectional ablation catheters on procedural parameters and acute success rates of ablation procedures is unknown. We retrospectively analyzed data regarding ablations using a novel bidirectional catheter in a tertiary cardiac center and compared these in 1:5 ratio with a control group of procedures matched for age, gender, operator, and ablation type. A total of 50 cases and 250 controls of median age 60 (50-68) years were studied. Structural heart disease was equally prevalent in both groups (39%) while history of previous ablations was more common in the study arm (54% vs 30%, P = 0.001). Most of the ablation cases were for atrial fibrillation (46%), followed by atrial tachycardia (28%), supraventricular tachycardia (12%), and ventricular tachycardia (14%). Median procedure duration was 128 (52-147) minutes with the bidirectional, versus 143 (105-200) minutes with the conventional catheter (P = 0.232), and median fluoroscopy time was 17 (10-34) minutes versus 23 (12-39) minutes, respectively (P = 0.988). There was a trend toward a lower procedure duration for the atrial tachycardia ablations, 89 (52-147) minutes versus 130 (100-210) minutes, P = 0.064. The procedure was successfully completed in 96% of the bidirectional versus 84% of the control cases (P = 0.151). A negative correlation was observed between the relative fluoroscopy duration and the case number (r = -0.312, P = 0.028), reflecting the learning curve for the bidirectional catheter. The introduction of the bidirectional catheter resulted in no prolongation of procedure parameters and similar success rates, while there was a trend toward a lower procedure duration for atrial tachycardia ablations. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  9. Periarticular Liposomal Bupivacaine Injection Versus Intra-Articular Bupivacaine Infusion Catheter for Analgesia After Total Knee Arthroplasty: A Double-Blinded, Randomized Controlled Trial.

    Science.gov (United States)

    Smith, Eric B; Kazarian, Gregory S; Maltenfort, Mitchell G; Lonner, Jess H; Sharkey, Peter F; Good, Robert P

    2017-08-16

    Intra-articular bupivacaine hydrochloride (HCl) infusion catheters and periarticular injections of liposomal bupivacaine are often used as postoperative local anesthetics. The purpose of this study was to compare the efficacies of these local anesthetics following total knee arthroplasty. This study was a superiority trial with a randomized, controlled, double-blinded design. Patients were randomly assigned to either delivery of bupivacaine HCl by the ON-Q* Pain Relief System pump (n = 96) or by an injection of Exparel (liposomal bupivacaine) (n = 104). The primary outcome of this study was cumulative narcotic consumption on postoperative days 0 through 3. Narcotic consumption data were collected retrospectively from in-hospital records while patients were in the hospital. Following discharge, narcotic consumption data were gathered from patient surveys, as were secondary outcomes measures. We did not identify greater narcotic use in the ON-Q* group compared with the Exparel group (p = 0.641). The mean difference between the groups was 0.5 morphine equivalent (95% confidence interval [CI] = -1.7 to +2.8), with the ON-Q* group consuming an average 10.4 morphine equivalents (95% CI = 8.7 to 12.0) compared with 10.9 (95% CI = 9.3 to 12.5) in the Exparel group. There were no significant differences between groups with regard to any of the secondary measures of pain with the exception of pain while walking and pain with physical therapy (p = 0.019 and p = 0.010, respectively), both of which showed an approximately 1-point difference in favor of the ON-Q* group on a visual analog scale (VAS). There were also no differences in the postoperative side effects, including nausea, constipation, or vomiting, or in the rates of study-related complications, patient satisfaction, or length of hospital stay. Exparel did not have superior efficacy compared with the ON-Q* Pain Relief System as reflected by narcotic consumption, our primary outcome. There were small significant

  10. Number and location of drainage catheter side holes: in vitro evaluation.

    Science.gov (United States)

    Ballard, D H; Alexander, J S; Weisman, J A; Orchard, M A; Williams, J T; D'Agostino, H B

    2015-09-01

    To evaluate the influence of number and location of catheter shaft side holes regarding drainage efficiency in an in vitro model. Three different drainage catheter models were constructed: open-ended model with no side holes (one catheter), unilateral side hole model (six catheters with one to six unilateral side holes), and bilateral side hole model (six catheters with one to six bilateral side holes). Catheters were inserted into a drainage output-measuring device with a constant-pressure reservoir of water. The volume of water evacuated by each of the catheters at 10-second intervals was measured. A total of five trials were performed for each catheter. Data were analysed using one-way analysis of variance. The open-ended catheter had a mean drainage volume comparable to the unilateral model catheters with three, four, and five side holes. Unilateral model catheters had significant drainage volume increases up to three side holes; unilateral model catheters with more than three side holes had no significant improvement in drainage volume. All bilateral model catheters had significantly higher mean drainage volumes than their unilateral counterparts. There was no significant difference between the mean drainage volume with one, two, or three pairs of bilateral side holes. Further, there was no drainage improvement by adding additional bilateral side holes. The present in vitro study suggests that beyond a critical side hole number threshold, adding more distal side holes does not improve catheter drainage efficiency. These results may be used to enhance catheter design towards improving their drainage efficiency. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  11. Suprapubic catheter care

    Science.gov (United States)

    ... going back into your bladder. Try not to disconnect the catheter more than you need to. Keeping ... Copyright Privacy Accessibility Quality Guidelines Viewers & Players MedlinePlus Connect for EHRs For Developers U.S. National Library of ...

  12. Echocardiographic assessment with right ventricular function improvement following ultrasound-accelerated catheter-directed thrombolytic therapy in submassive pulmonary embolism.

    Science.gov (United States)

    Doheny, Charles; Gonzalez, Lorena; Duchman, Stanley M; Varon, Joseph; Bechara, Carlos F; Cheung, Mathew; Lin, Peter H

    2018-06-01

    Introduction The objective of this study was to evaluate the efficacy of ultrasound-accelerated catheter-directed thrombolytic therapy in patients with submassive pulmonary embolism. Methods Clinical records of 46 patients with submassive pulmonary embolism who underwent ultrasound-accelerated catheter-directed pulmonary thrombolysis using tissue plasminogen activator, from 2007 to 2017, were analyzed. All patients experienced clinical symptoms with computed tomography evidence of pulmonary thrombus burden. Right ventricular dysfunction was present in all patients by echocardiographic finding of right ventricle-to-left ventricle ratio > 0.9. Treatment outcome, procedural complications, right ventricular pressures, and thrombus clearance were evaluated. Follow-up evaluation included echocardiographic assessment of right ventricle-to-left ventricle ratio at one month, six months, and one year. Results Technical success was achieved in all patients ( n = 46, 100%). Our patients received an average of 18.4 ± 4.7 mg of tissue plasminogen activator using ultrasound-accelerated thrombolytic catheter with an average infusion time of 16.5± 5.4 h. Clinical success was achieved in all patients (100%). Significant reduction of mean pulmonary artery pressure occurred following the treatment, which decreased from 36 ± 8 to 21 ± 5 mmHg ( p right ventricular dysfunction based on echocardiographic assessment. The right ventricle-to-left ventricle ratio decreased from 1.32 ± 0.18 to 0.91 ± 0.13 at the time of hospital discharge ( p right ventricular function remained improved at 6 months and 12 months of follow-up, as right ventricle-to-left ventricle ratio were 0.92 ± 0.14 ( p right ventricular function in patients with submassive pulmonary embolism.

  13. Three-Catheter Technique for Ablation of Left-Sided Accessory Pathways in Wolff-Parkinson-White is Less Expensive and Equally Successful When Compared to a Five-Catheter Technique.

    Science.gov (United States)

    Capone, Christine A; Ceresnak, Scott R; Nappo, Lynn; Gates, Gregory J; Schechter, Clyde B; Pass, Robert H

    2015-12-01

    To compare the efficacy, safety, and cost-effectiveness of a three-catheter approach with a conventional five-catheter approach for the mapping and ablation of supraventricular tachycardia in pediatric patients with Wolff-Parkinson-White Syndrome (WPW) and concealed accessory pathways (APs). A retrospective review from 2008 to 2012 of patients less than 21 years with WPW who underwent a three-catheter radiofrequency (RF) ablation of a left-sided AP (ablation, right ventricular [RV] apical, and coronary sinus [CS] decapolar catheters) was performed. The three-catheter group was compared to a control group who underwent a standard five-catheter (ablation, RV apical, CS decapolar, His catheter, and right atrial catheter) ablation for the treatment of left-sided WPW or concealed AP. Demographics, ablation outcomes, and costs were compared between groups. Twenty-eight patients met inclusion criteria with 28 control patients. The groups did not differ in gender, age, weight, or body surface area. Locations of the AP on the mitral annulus were similar between the groups. All patients were ablated via transseptal approach. Note that 28 of 28 in the three-catheter group (100%) and 27 of 28 (96%) controls were acutely successfully ablated (P = 0.31). No complications were encountered. There was no difference in procedural time, time to loss of AP conduction, or number of RF applications. Use of the three-catheter technique resulted in a total savings of $2,465/case, which includes the $680 savings from using fewer catheters as well as the savings from a shortened procedure time. Ablation in patients with WPW and a left-sided AP can be performed using three catheters with similar efficacy and safety while offering significant cost savings compared to a conventional five-catheter approach. © 2015 Wiley Periodicals, Inc.

  14. Balloon-tipped flow-directed catheters

    International Nuclear Information System (INIS)

    Ganz, P.; Swan, H.J.C.; Ganz, W.

    1986-01-01

    Diagnostic catheterization of the right side of the heart with semirigid cardiac catheters requires fluoroscopic guidance and substantial skill. Abnormal positions of the heart chambers and of the great vessels associated with cardiac dilatation or with congenital malformation present difficulties even to experienced laboratory cardiologists. These problems have been largely overcome by the introduction of balloon tipped flow directed catheters, which allow for rapid and relatively safe catheterization of the pulmonary artery without fluoroscopy. It was through the application of these catheters in the intensive care unit that the many pitfalls in the clinical assessment of hemodynamic disturbances became apparent. Although S3 gallop sounds may be useful in the clinical recognition of chronic ventricular failure, their presence or absence has limited predictive value in estimating left ventricular filling pressure in myocardial infarction. Information derived from right heart catheterization is often pivotal in the evaluation of hemodynamic disorders, in directing treatment, and in monitoring the results of therapy in critically ill patients

  15. Translumbar aortography by catheter technique

    International Nuclear Information System (INIS)

    Hagen, B.; Honemeyer, U.; Meier-Duis, H.

    1982-01-01

    400 examinations performed during the last three years by TLA (only catheter technique) were subjected to critical analysis and studied particularly in respect to the rate of complications. We observed 13 complications (3.25%) of moderate severity, including 3 large hematomas (documented by CT), 3 paravasations and 7 dissections, but no fatal complication. Two (0.5%) of these complications had clinical evidence. The advantages of the catheter technique of TLA are described. Injections through rigid metal cannula should be avoided because of the high incidence of complications (mainly the increased risk of dissection). Downstream injection resulted in excellent visualization of peripheral occluding vascular disease. Upstream injection should be preferred to demonstrate the major abdominal arteries as well as supraceliac collateral circulation in the case of high Leriche syndrome. The low or intermediate puncture of the aorta is preferable to facilitate caudad direction of the catheter and to diminish the risk of damaging other vessels or puncturing an organ. (orig.) [de

  16. Assessment of implantable infusion pumps for continuous infusion of human insulin in rats: potential for group housing

    DEFF Research Database (Denmark)

    Jensen, Vivi Flou Hjorth; Molck, Anne-Marie; Martensson, Martin

    2017-01-01

    compound in these studies, and a comparator model of persistent exposure by HI infusion from external pumps has recently been developed to support toxicological evaluation of long-acting insulin analogues. However, this model requires single housing of the animals. Developing an insulin-infusion model...... which allows group housing would therefore greatly improve animal welfare. The aim of the present study was to investigate the suitability of implantable infusion pumps for HI infusion in group-housed rats. Group housing of rats implanted with a battery-driven pump proved to be possible. Intravenous...... infusion of HI lowered blood glucose levels persistently for two weeks, providing a comparator model for use in two-week repeated-dose toxicity studies with new long-acting insulin analogues, which allows group housing, and thereby increasing animal welfare compared with an external infusion model....

  17. Catheter-associated UTI

    Science.gov (United States)

    ... UTI; Health care-associated UTI; Catheter-associated bacteriuria; Hospital acquired-UTI Images Bladder catheterization, female Bladder catheterization, male References Calfee DP. Prevention and control of health care-associated infections. In: Goldman L, Schafer AI, eds. Goldman's Cecil ...

  18. Effective ultraviolet irradiation of platelet concentrates in teflon bags

    International Nuclear Information System (INIS)

    Capon, S.M.; Sacher, R.A.; Deeg, H.J.

    1990-01-01

    Several plastic materials used in blood storage were evaluated for their ability to transmit ultraviolet B (UVB) light. A plastic bag manufactured from sheets of transparent Teflon efficiently (78-86%) transmitted UVB light and was employed in subsequent functional studies of lymphocytes and platelets exposed to UVB light while contained in these bags. In vitro experiments showed a UVB dose-dependent abrogation of lymphocyte responder and stimulator functions, with concurrent preservation of platelet aggregation responses. In a phase I pilot study, UVB-treated platelet concentrates were administered to four bone marrow transplant recipients. Adverse effects attributable to the transfusions were not observed, and patients showed clinically effective transfusion responses. No patient developed lymphocytotoxic HLA or platelet antibodies. These studies suggest that platelets can be effectively irradiated with UVB light in a closed system. However, numerous variables, including container material, volume and composition of contents, steady exposure versus agitation, and exact UV wavelength, must be considered

  19. Selective arterial thrombolysis with urokinase

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jae Hyung; Park, Kil Sun; Chung, Jin Wook; Han, Joon Koo; Kim, Sang Joon [Seoul National University College of Medicine, Seoul (Korea, Republic of); Kim, Dae Young [Choong Buk University College of Medicine, Jeonju (Korea, Republic of)

    1991-07-15

    Seven patients with thrombotic occlusions of the peripheral arteries or grafts were treated with urokinase by direct intraarterial selective infusion. During the infusion, simultaneous heparin infusion was used to reduce the frequency of thrombus formation on the infusion catheter or recurrent thrombosis. In 4 patients in whom a complete thrombolysis occurred, urokinase was infused by a high-dose transthrombus bolus technique followed by continuous infusion. There other patients, in whom thrombolysis was partially accomplished and then surgical thrombectomy was performed, were treated only by continuous urokinase infusion. Small hematomas developed at the infusion catheter entry site in 2 patients, but transfusion or operation was not required. Other significant complications were not found. Our results suggest that selective arterial infusion of urokinase with a transthrombus bolus technique can accomplish a complete arterial thrombolysis without any significant complications.

  20. Selective arterial thrombolysis with urokinase

    International Nuclear Information System (INIS)

    Park, Jae Hyung; Park, Kil Sun; Chung, Jin Wook; Han, Joon Koo; Kim, Sang Joon; Kim, Dae Young

    1991-01-01

    Seven patients with thrombotic occlusions of the peripheral arteries or grafts were treated with urokinase by direct intraarterial selective infusion. During the infusion, simultaneous heparin infusion was used to reduce the frequency of thrombus formation on the infusion catheter or recurrent thrombosis. In 4 patients in whom a complete thrombolysis occurred, urokinase was infused by a high-dose transthrombus bolus technique followed by continuous infusion. There other patients, in whom thrombolysis was partially accomplished and then surgical thrombectomy was performed, were treated only by continuous urokinase infusion. Small hematomas developed at the infusion catheter entry site in 2 patients, but transfusion or operation was not required. Other significant complications were not found. Our results suggest that selective arterial infusion of urokinase with a transthrombus bolus technique can accomplish a complete arterial thrombolysis without any significant complications

  1. A computational fluid dynamics simulation framework for ventricular catheter design optimization.

    Science.gov (United States)

    Weisenberg, Sofy H; TerMaath, Stephanie C; Barbier, Charlotte N; Hill, Judith C; Killeffer, James A

    2017-11-10

    OBJECTIVE Cerebrospinal fluid (CSF) shunts are the primary treatment for patients suffering from hydrocephalus. While proven effective in symptom relief, these shunt systems are plagued by high failure rates and often require repeated revision surgeries to replace malfunctioning components. One of the leading causes of CSF shunt failure is obstruction of the ventricular catheter by aggregations of cells, proteins, blood clots, or fronds of choroid plexus that occlude the catheter's small inlet holes or even the full internal catheter lumen. Such obstructions can disrupt CSF diversion out of the ventricular system or impede it entirely. Previous studies have suggested that altering the catheter's fluid dynamics may help to reduce the likelihood of complete ventricular catheter failure caused by obstruction. However, systematic correlation between a ventricular catheter's design parameters and its performance, specifically its likelihood to become occluded, still remains unknown. Therefore, an automated, open-source computational fluid dynamics (CFD) simulation framework was developed for use in the medical community to determine optimized ventricular catheter designs and to rapidly explore parameter influence for a given flow objective. METHODS The computational framework was developed by coupling a 3D CFD solver and an iterative optimization algorithm and was implemented in a high-performance computing environment. The capabilities of the framework were demonstrated by computing an optimized ventricular catheter design that provides uniform flow rates through the catheter's inlet holes, a common design objective in the literature. The baseline computational model was validated using 3D nuclear imaging to provide flow velocities at the inlet holes and through the catheter. RESULTS The optimized catheter design achieved through use of the automated simulation framework improved significantly on previous attempts to reach a uniform inlet flow rate distribution using

  2. [Recording of ventricular pressure by conventional catheter manometer systems. Efficiency of several combinations of conventional catheters, modern transducers and catheter-flush systems (author's transl)].

    Science.gov (United States)

    Hellige, G

    1976-01-01

    The experimentally in vitro determined dynamic response characteristics of 38 catheter manometer systems were uniform in the worst case to 5 c.p.s. and optimally to 26 c.p.s. Accordingly, some systems are only satisfactory for ordinary pressure recording in cardiac rest, while better systems record dp/dt correct up to moderate inotropic stimulation of the heart. In the frequency range of uniform response (amplitude error less +/- 5%) the phase distortion is also negligible. In clinical application the investigator is often restricted to special type of cardiac catheter. In this case a low compliant transducer yields superior results. In all examined systems the combination with MSD 10 transducers is best, whereas the combination with P 23 Db transducers leads to minimal results. An inadequate system for recording ventricular pressure pulses leads in most cases to overestimations of dp/dtmax. The use of low frequency pass filters to attenuate higher frequency artefacts is, under clinical conditions, not suitable for extending the range of uniform frequency response. The dynamic response of 14 catheter manometer systems with two types of continuous self flush units was determined. The use of the P 37 flush unit in combination with small internal diameter catheters leads to serious error in ordinary pressure recording, due to amplitude distortion of the lower harmonics. The frequency response characteristics of the combination of an Intraflow flush system and MSD 10 transducer was similar to the non-flushing P 23 Db transducer feature.

  3. Delayed post-surgical sepsis from Teflon felt: The diagnostic value of CT scanning, and a reminder for theatre staff

    Directory of Open Access Journals (Sweden)

    D Emby

    2011-05-01

    Full Text Available We report on 2 patients with surgical site infections following the inadvertent use of Teflon felt for haemostasis in elective and emergency surgery. CT scanning was superior to plain radiography in demonstrating the foreign bodies to enable planning of further surgical treatment.

  4. Compatibility of electrolytically produced sodium hypochlorite solutions on long- term implanted dialysis catheters.

    Science.gov (United States)

    Mishkin, G J

    2007-01-01

    More than 20% of the world's population use a catheter for dialysis, despite guidelines limiting their use. Although the structure and design of the catheters differ by manufacturer, the material used in central venous catheters and peritoneal dialysis catheters are the same across manufacturers. Given the long-term use of these catheters in the dialysis population, the good compatibility of the antiseptics and disinfectants used on the catheters is imperative to prevent failure and cracking of the catheter material. Tensile strengths of commercially available catheters were measured after exposure to commonly used disinfectants. The tensile strength was then compared between the catheters by analyzing the displacement vs. force (N) curves produced during the evaluation. A total of 44 catheter lumens were evaluated. The electrolytically produced sodium hypochlorite solution, Alcavis 50/ExSept Plus, was the only solution shown to be compatible with all three catheter materials resulting in a deviation of less than 10% for each of the different catheter types. Electrolytically produced sodium hypochlorite solutions were the only solutions in this study that did not alter the physical properties of any of the catheters after long-term exposure.

  5. The value of percutaneous catheter cholangiography in postoperative diagnostics after biliobiliary and biliodigestive anastomoses; Wertigkeit der perkutanen Kathetercholangiographie in der postoperativen Diagnostik biliodigestiver und biliobiliaerer Anastomosen

    Energy Technology Data Exchange (ETDEWEB)

    Barkhausen, J. [Zentralinstitut fuer Roentgendiagnostik, Universitaetsklinikum Essen (Germany); Bidlingmaier, J. [Zentralinstitut fuer Roentgendiagnostik, Universitaetsklinikum Essen (Germany); Mueller, R.D. [Zentralinstitut fuer Roentgendiagnostik, Universitaetsklinikum Essen (Germany); Langer, R. [Zentralinstitut fuer Roentgendiagnostik, Universitaetsklinikum Essen (Germany)

    1996-09-01

    Aim of study: To examine the relative importance of percutaneous catheter cholangiography in postoperative diagnostics after biliary reconstruction. Methods: 55 patients (33 males, 22 females) were subjected to 101 catheter cholangiographies. 30-50 ml of a water-soluble, iodic contrast medium were administered via an infusion system. Initial examinations were performed between the 3nd and 7th day following operation, while follow-up examinations were executed between the 8th and 145th day after surgery. The position of the catheter, the function of the anastomosis, the filling of the biliary ducts and the discharge of the contrast medium were assessed. Results: 45 examinations were inconspicuous. Drainage obstruction of the contrast medium was observed in 24 cases. Filling defects were observed in 8 examinations. A dislocation of the catheter was encountered in 5 cholangiographies while 19 examinations displayed a bile leak. Conclusion: Percutaneous catheter cholangiographies can be used to detect postoperative complications following biliary reconstruction in an easy, reliable, and cost-effective manner that also does not put too much strain on the patient. Indications for the inplementation of catheter cholangiographies are the occurrence of abdominal complaints, the clinical appearance of a peritonitis, or an increase of the serum bilirubin value. Routine examinations are recommended in conditions following liver transplantations. In addition to this, a cholangiography should be carried out prfor to the removal of the catheter. (orig.) [Deutsch] Fragestellung: Geprueft wird der Stellenwert der perkutanen Kathetercholangiographie in der postoperativen Diagnostik nach Anlage biliobiliaerer und biliodigestiver Anastomosen. Material und Methode: Bei 55 Patienten (33 maennlich, 22 weiblich) wurden 101 Kathetercholangiographien durchgefuehrt. Die Erstuntersuchung erfolgte zwischen dem 3. und 7. postoperativen Tag, Kontrolluntersuchungen zwischen dem 8. und 145. Tag

  6. Percutaneous untying of a knot in a retained Swan-Ganz catheter

    International Nuclear Information System (INIS)

    Bhatti, Waqar A.; Sinha, Sankar; Rowlands, Peter

    2000-01-01

    A patient was referred to us with a tightly knotted Swan-Ganz catheter. The catheter could not be removed by conventional simple methods. We describe a minimally invasive means of removal of the catheter using an Amplatz gooseneck snare and an angioplasty balloon. This allowed the Catheter to be removed without trauma.

  7. Dialysis catheter-related septicaemia--focus on Staphylococcus aureus septicaemia

    DEFF Research Database (Denmark)

    Nielsen, J; Ladefoged, S D; Kolmos, H J

    1998-01-01

    BACKGROUND: Dialysis catheters are a common cause of nosocomial septicaemia in haemodialysis units usually due to staphylococci, of which Staphylococcus aureus is the most pathogenic. In this study, the epidemiology and pathogenesis of dialysis catheter-related infections were studied, and methods...... to infection were measured. After catheter insertion, all patients were screened for nasal carriage of S. aureus, and a culture was taken from the skin overlying the catheter insertion site. Once a week, cultures were taken from the insertion site and from the hub, and aerobic and anaerobic blood cultures were...... drawn from the catheter. If clinical signs of septicaemia occurred, peripheral blood cultures were also performed, when it was possible. RESULTS: The incidence of septicaemia was 49% (21/43) in patients, and 56% of all cases were caused by S. aureus. The mortality was 14% (3/21) and the incidence...

  8. Radiological Tenckhoff catheter insertion for peritoneal dialysis: A cost-effective approach.

    Science.gov (United States)

    Lee, James; Mott, Nigel; Mahmood, Usman; Clouston, John; Summers, Kara; Nicholas, Pauline; Gois, Pedro Henrique França; Ranganathan, Dwarakanathan

    2018-04-01

    Radiological insertion of Tenckhoff catheters can be an alternative option for peritoneal dialysis access creation, as compared to surgical catheter insertion. This study will review the outcomes and complications of radiological Tenckhoff catheter insertion in a metropolitan renal service and compare costs between surgical and radiological insertion. Data were collected prospectively for all patients who had a Tenckhoff catheter insertion for peritoneal dialysis (PD) under radiological guidance at our hospital from May 2014 to November 2016. The type of catheter used and complications, including peri-catheter leak, exit site infection and peritonitis were reviewed. Follow-up data were also collected at points 3, 6 and 12 months from catheter insertion. Costing data were obtained from Queensland Health Electronic Reporting System (QHERS) data, average staff salaries and consumable contract price lists. In the 30-month evaluation period, 70 catheters were inserted. Two patients had an unsuccessful procedure due to the presence of abdominal adhesions. Seven patients had an episode of peri-catheter leak, and four patients had an exit site infection following catheter insertion. Peritonitis was observed in nine patients during the study period. The majority of patients (90%) remained on peritoneal dialysis at 3-month follow-up. The average costs of surgical and radiological insertion were noted to be AUD$7788.34 and AUD$1597.35, respectively. Radiological Tenckhoff catheter insertion for peritoneal dialysis appears to be an attractive and cost-effective option given less waiting periods for the procedure, the relatively low cost of insertion and comparable rates of complications. © 2017 The Royal Australian and New Zealand College of Radiologists.

  9. Comparison of air-charged and water-filled urodynamic pressure measurement catheters.

    Science.gov (United States)

    Cooper, M A; Fletter, P C; Zaszczurynski, P J; Damaser, M S

    2011-03-01

    Catheter systems are utilized to measure pressure for diagnosis of voiding dysfunction. In a clinical setting, patient movement and urodynamic pumps introduce hydrostatic and motion artifacts into measurements. Therefore, complete characterization of a catheter system includes its response to artifacts as well its frequency response. The objective of this study was to compare the response of two disposable clinical catheter systems: water-filled and air-charged, to controlled pressure signals to assess their similarities and differences in pressure transduction. We characterized frequency response using a transient step test, which exposed the catheters to a sudden change in pressure; and a sinusoidal frequency sweep test, which exposed the catheters to a sinusoidal pressure wave from 1 to 30 Hz. The response of the catheters to motion artifacts was tested using a vortex and the response to hydrostatic pressure changes was tested by moving the catheter tips to calibrated heights. Water-filled catheters acted as an underdamped system, resonating at 10.13 ± 1.03 Hz and attenuating signals at frequencies higher than 19 Hz. They demonstrated significant motion and hydrostatic artifacts. Air-charged catheters acted as an overdamped system and attenuated signals at frequencies higher than 3.02 ± 0.13 Hz. They demonstrated significantly less motion and hydrostatic artifacts than water-filled catheters. The transient step and frequency sweep tests gave comparable results. Air-charged and water-filled catheters respond to pressure changes in dramatically different ways. Knowledge of the characteristics of the pressure-measuring system is essential to finding the best match for a specific application. Copyright © 2011 Wiley-Liss, Inc.

  10. Uso de cateteres venosos totalmente implantados para nutrição parenteral: cuidados, tempo de permanência e ocorrência de complicações infecciosas Long-term central venous catheter for total parenteral nutrition: catheter care, permanence period, and incidence of infections

    Directory of Open Access Journals (Sweden)

    Maria do Rosário Del Lama de Unamuno

    2005-04-01

    Full Text Available Cateteres venosos totalmente implantados são utilizados em pacientes com síndrome do intestino curto, para realizar o suporte nutricional parenteral, o qual mantém estes pacientes vivos, pois fornece-lhes nutrientes que são absorvidos pela via digestiva. No entanto, estes cateteres não são isentos de complicações. As infecções relacionadas aos cateteres venosos são as complicações mais temidas e sua incidência varia de 3% a 20%, aumentando em pacientes mais graves. O objetivo do presente estudo é descrever as complicações infecciosas em pacientes recebendo nutrição parenteral por meio de cateteres venosos totalmente implantados. Tais cateteres são utilizados pela Divisão de Nutrição Clínica do Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, para realizar o suporte nutricional parenteral em pacientes submetidos a ressecções extensas de intestino delgado. Foram avaliadas as complicações infecciosas ocorridas com 21 cateteres, implantados em 16 pacientes. O tempo de permanência dos cateteres foi de 768±664,3 dias (mediana 529 dias e a taxa de infecção foi de 0,029 infecções/paciente/ano, resultados que se comparam às taxas de infecção observadas em países desenvolvidos. Concluiu-se que os cuidados observados no manuseio destes cateteres foram de fundamental importância para diminuir a incidência de infecção nestes pacientes.Long-term venous catheters are used for the total parenteral nutrition infusion, which is essential for feeding short-bowel syndrome patients. However, complications are likely to occur. The incidence of catheter related infections ranges from 3 to 20% in hospitalized patients. The Divisão de Nutrição Clínica do Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto, University of São Paulo, Brazil, has been providing nutrition support to short-bowel syndrome patients, using totally implantable venous catheters. This is a

  11. Reducing unnecessary urinary catheter use and other strategies to prevent catheter-associated urinary tract infection: an integrative review

    Science.gov (United States)

    Meddings, Jennifer; Rogers, Mary A M; Krein, Sarah L; Fakih, Mohamad G; Olmsted, Russell N; Saint, Sanjay

    2014-01-01

    Background Catheter-associated urinary tract infections (CAUTI) are costly, common and often preventable by reducing unnecessary urinary catheter (UC) use. Methods To summarise interventions to reduce UC use and CAUTIs, we updated a prior systematic review (through October 2012), and a meta-analysis regarding interventions prompting UC removal by reminders or stop orders. A narrative review summarises other CAUTI prevention strategies including aseptic insertion, catheter maintenance, antimicrobial UCs, and bladder bundle implementation. Results 30 studies were identified and summarised with interventions to prompt removal of UCs, with potential for inclusion in the meta-analyses. By meta-analysis (11 studies), the rate of CAUTI (episodes per 1000 catheter-days) was reduced by 53% (rate ratio 0.47; 95% CI 0.30 to 0.64, p<0.001) using a reminder or stop order, with five studies also including interventions to decrease initial UC placement. The pooled (nine studies) standardised mean difference (SMD) in catheterisation duration (days) was −1.06 overall (p=0.065) including a statistically significant decrease in stop-order studies (SMD −0.37; p<0.001) but not in reminder studies (SMD, −1.54; p=0.071). No significant harm from catheter removal strategies is supported. Limited research is available regarding the impact of UC insertion and maintenance technique. A recent randomised controlled trial indicates antimicrobial catheters provide no significant benefit in preventing symptomatic CAUTIs. Conclusions UC reminders and stop orders appear to reduce CAUTI rates and should be used to improve patient safety. Several evidence-based guidelines have evaluated CAUTI preventive strategies as well as emerging evidence regarding intervention bundles. Implementation strategies are important because reducing UC use involves changing well-established habits. PMID:24077850

  12. Embolization of brain arteriovenous malformations using tracker catheter

    International Nuclear Information System (INIS)

    Kim, Sun Yong; Son, Mi Young; Jang, Jae Chun; Hwang, Mi Soo; Park, Bok Hwan

    1990-01-01

    With the recent advance in micro catheters, steerable guide wires, balloons, embolic materials and digital subtraction angiography (DSA), as well as technical refinements in endovascular surgery, there has been a revolution in therapeutic strategies for cerebral arteriovenous malformations (AVMs). We have performed super selective angiography and embolization with Tracker micro catheter about 12 cases of brain AVMs for therapeutic and preoperative aims. This micro catheter and guide wire provided high selectivity of feeding artery, greater maneuverability and useful for deliver various embolus materials

  13. Adverse effects associated with ethanol catheter lock solutions: a systematic review.

    Science.gov (United States)

    Mermel, Leonard A; Alang, Neha

    2014-10-01

    Antimicrobial lock therapy has been widely utilized internationally for the prevention and management of intravascular catheter-related bloodstream infections. One of the agents commonly utilized for lock therapy is ethanol. However, a systematic review of adverse events associated with ethanol locks has not been published. PubMed was searched to collect articles published from May 2003 through March 2014. The bibliographies of relevant articles were also reviewed. In vitro studies of the mechanical properties of catheters after ethanol immersion have revealed changes predominantly in polyurethane catheters and to a lesser extent in silicone and Carbothane catheters. An elution of polymers from polyurethane and Carbothane catheters has been observed at the ethanol concentrations used in ethanol lock therapy. Ethanol above a concentration of 28% leads to plasma protein precipitation. Ethanol locks were associated with catheter occlusion in 11 studies and independently increased the risk of thrombosis compared with heparin lock in a randomized trial. Six studies noted abnormalities in catheter integrity, including one case leading to catheter embolization. Of note, five of these studies involved silicone catheters. Ethanol lock use was associated with systemic side effects in 10 studies and possible side effects in one additional study. Four studies noted liver function test abnormalities, predominantly transaminase elevation, related to ethanol lock use. However, a prospective study did not find any difference in the risk of doubling the transaminase level above the normal range during use of ethanol locks compared with not using an ethanol lock. The use of ethanol locks has been associated with structural changes in catheters, as well as the elution of molecules from the catheter polymers. Clinical studies have revealed systemic toxicity, increased catheter occlusion and breaches in catheter integrity. © The Author 2014. Published by Oxford University Press on

  14. Potential In Vivo UVC Disinfection of Catheter Lumens: Estimation of the Doses Received by the Blood Flow Outside the Catheter Tip Hole

    DEFF Research Database (Denmark)

    Bak, Jimmy; Jørgensen, Thomas Martini; Helfmann, Jurgen

    2011-01-01

    hole for administration of drugs, bloods or nutrients into the bloodstream. Even if the UVC light is strongly attenuated during its propagation through the catheter tube a fraction of the UVC launched into the catheter will escape through the exit hole and irradiate the blood. We demonstrate......We have demonstrated that it is possible to launch UVC LED light into bacterial contaminated polymer tubes/catheters and disinfect the intraluminal space of these tubes. This can be achieved by UVC treatment of the catheters on a regular basis. Catheters are in the distal end equipped with an exit...... by calculations that very small effective doses are exposed to the blood (ca 10(-4) J m(-2) ). This dosage level is very low compared with UVC doses reported from other therapeutic applications. The very short residence time of the blood constituents in the irradiated volume in front of the exit hole is the main...

  15. The effect of elastic modulus on ablation catheter contact area.

    Science.gov (United States)

    Camp, Jon J; Linte, Cristian A; Rettmann, Maryam E; Sun, Deyu; Packer, Douglas L; Robb, Richard A; Holmes, David R

    2015-02-21

    Cardiac ablation consists of navigating a catheter into the heart and delivering RF energy to electrically isolate tissue regions that generate or propagate arrhythmia. Besides the challenges of accurate and precise targeting of the arrhythmic sites within the beating heart, limited information is currently available to the cardiologist regarding intricate electrode-tissue contact, which directly impacts the quality of produced lesions. Recent advances in ablation catheter design provide intra-procedural estimates of tissue-catheter contact force, but the most direct indicator of lesion quality for any particular energy level and duration is the tissue-catheter contact area, and that is a function of not only force, but catheter pose and material elasticity as well. In this experiment, we have employed real-time ultrasound (US) imaging to determine the complete interaction between the ablation electrode and tissue to accurately estimate contact, which will help to better understand the effect of catheter pose and position relative to the tissue. By simultaneously recording tracked position, force reading and US image of the ablation catheter, the differing material properties of polyvinyl alcohol cryogel [1] phantoms are shown to produce varying amounts of tissue depression and contact area (implying varying lesion quality) for equivalent force readings. We have shown that the elastic modulus significantly affects the surface-contact area between the catheter and tissue at any level of contact force. Thus we provide evidence that a prescribed level of catheter force may not always provide sufficient contact area to produce an effective ablation lesion in the prescribed ablation time.

  16. Strontium-rubidium infusion pump with in-line dosimetry

    International Nuclear Information System (INIS)

    Barker, S.L.; Loberg, M.D.

    1986-01-01

    A strontium-rubidium infusion system is described which consists of: (a) means for generating rubidium 82 in a solution which can be infused into a patient; (b) means for infusing the solution into a patient; (c) means for measuring the radioactivity present in the solution as it is infused into the patient; and (d) means for controlling the means for infusing in response to the amount of radioactivity which has been infused into the patient

  17. SU-F-T-20: Novel Catheter Lumen Recognition Algorithm for Rapid Digitization

    Energy Technology Data Exchange (ETDEWEB)

    Dise, J; McDonald, D; Ashenafi, M; Peng, J; Mart, C; Koch, N; Vanek, K [Medical University of South Carolina, Charleston, SC (United States)

    2016-06-15

    Purpose: Manual catheter recognition remains a time-consuming aspect of high-dose-rate brachytherapy (HDR) treatment planning. In this work, a novel catheter lumen recognition algorithm was created for accurate and rapid digitization. Methods: MatLab v8.5 was used to create the catheter recognition algorithm. Initially, the algorithm searches the patient CT dataset using an intensity based k-means filter designed to locate catheters. Once the catheters have been located, seed points are manually selected to initialize digitization of each catheter. From each seed point, the algorithm searches locally in order to automatically digitize the remaining catheter. This digitization is accomplished by finding pixels with similar image curvature and divergence parameters compared to the seed pixel. Newly digitized pixels are treated as new seed positions, and hessian image analysis is used to direct the algorithm toward neighboring catheter pixels, and to make the algorithm insensitive to adjacent catheters that are unresolvable on CT, air pockets, and high Z artifacts. The algorithm was tested using 11 HDR treatment plans, including the Syed template, tandem and ovoid applicator, and multi-catheter lung brachytherapy. Digitization error was calculated by comparing manually determined catheter positions to those determined by the algorithm. Results: he digitization error was 0.23 mm ± 0.14 mm axially and 0.62 mm ± 0.13 mm longitudinally at the tip. The time of digitization, following initial seed placement was less than 1 second per catheter. The maximum total time required to digitize all tested applicators was 4 minutes (Syed template with 15 needles). Conclusion: This algorithm successfully digitizes HDR catheters for a variety of applicators with or without CT markers. The minimal axial error demonstrates the accuracy of the algorithm, and its insensitivity to image artifacts and challenging catheter positioning. Future work to automatically place initial seed

  18. SU-F-T-20: Novel Catheter Lumen Recognition Algorithm for Rapid Digitization

    International Nuclear Information System (INIS)

    Dise, J; McDonald, D; Ashenafi, M; Peng, J; Mart, C; Koch, N; Vanek, K

    2016-01-01

    Purpose: Manual catheter recognition remains a time-consuming aspect of high-dose-rate brachytherapy (HDR) treatment planning. In this work, a novel catheter lumen recognition algorithm was created for accurate and rapid digitization. Methods: MatLab v8.5 was used to create the catheter recognition algorithm. Initially, the algorithm searches the patient CT dataset using an intensity based k-means filter designed to locate catheters. Once the catheters have been located, seed points are manually selected to initialize digitization of each catheter. From each seed point, the algorithm searches locally in order to automatically digitize the remaining catheter. This digitization is accomplished by finding pixels with similar image curvature and divergence parameters compared to the seed pixel. Newly digitized pixels are treated as new seed positions, and hessian image analysis is used to direct the algorithm toward neighboring catheter pixels, and to make the algorithm insensitive to adjacent catheters that are unresolvable on CT, air pockets, and high Z artifacts. The algorithm was tested using 11 HDR treatment plans, including the Syed template, tandem and ovoid applicator, and multi-catheter lung brachytherapy. Digitization error was calculated by comparing manually determined catheter positions to those determined by the algorithm. Results: he digitization error was 0.23 mm ± 0.14 mm axially and 0.62 mm ± 0.13 mm longitudinally at the tip. The time of digitization, following initial seed placement was less than 1 second per catheter. The maximum total time required to digitize all tested applicators was 4 minutes (Syed template with 15 needles). Conclusion: This algorithm successfully digitizes HDR catheters for a variety of applicators with or without CT markers. The minimal axial error demonstrates the accuracy of the algorithm, and its insensitivity to image artifacts and challenging catheter positioning. Future work to automatically place initial seed

  19. Percutaneous Management of Postoperative Duodenal Stump Leakage with Foley Catheter

    International Nuclear Information System (INIS)

    Oh, Jung Suk; Lee, Hae Giu; Chun, Ho Jong; Choi, Byung Gil; Lee, Sang Hoon; Hahn, Seong Tai; Ohm, Joon Young

    2013-01-01

    Purpose: This study was designed to evaluate retrospectively the safety and efficacy of the percutaneous management of duodenal stump leakage with a Foley catheter after subtotal gastrectomy. Methods: Ten consecutive patients (M:F = 9:1, median age: 64 years) were included in this retrospective study. The duodenal stump leakages were diagnosed in all the patients within a median of 10 days (range, 6–20). At first, the patients underwent percutaneous drainage on the day of or the day after confirmation of the presence of duodenal stump leakage, and then the Foley catheters were replaced at a median of 9 days (range, 6–38) after the percutaneous drainage. Results: Foley catheters were placed successfully in the duodenal lumen of all the patients under a fluoroscopic guide. No complication was observed during and after the procedures in all the patients. All of the patients started a regular diet 1 day after the Foley catheter placement. The patients were discharged at a median of 7 days (range, 5–14) after the Foley catheter placement. The catheters were removed in an outpatient clinic 10–58 days (median, 28) after the Foley catheter placement. Conclusions: Fluoroscopy-guided percutaneous Foley catheter placement may be a safe and effective treatment option for postoperative duodenal stump leakage and may allow for shorter hospital stays, earlier oral intake, and more effective control of leakage sites

  20. The U.S. home infusion market.

    Science.gov (United States)

    Monk-Tutor, M R

    1998-10-01

    Medicare legislation stimulated the development of home care services but also resulted in fragmentation of service components. In the 1980s, prospective pricing and diagnosis-related groups, and resulting pressures to reduce inpatient length of stay, prompted additional growth of the industry. Even so, in 1995 home care represented only 3% of total national expenditures on health care. The annual growth rate of the home infusion industry dropped from 64% in 1982-86 to 24% in 1986-93. While revenue per patient for home infusion is expected to decrease under managed care, an increasing number of patients will support continued market growth. The home infusion market is highly competitive, with only a few large national providers and many small local providers. In 1996, 29% of acute care hospitals provided or were developing a home care program. Community pharmacists' options in the home infusion area include independent services, partnerships, joint ventures, contracts with hospitals, and franchises. The home infusion market is being integrated into alternative sites, such as ambulatory infusion centers (AICs), as providers attempt to diversify to maintain managed care contracts. AICs provide infusion therapy and nursing to noninstitutionalized, nonhome-bound patients. Untapped sources for future growth of the infusion market include long-term-care facilities. More consistent studies of the home care market are needed. Despite slowed growth in recent years, home care has a strong market in the United States.

  1. Mass transfer in fuel cells. [electron microscopy of components, thermal decomposition of Teflon, water transport, and surface tension of KOH solutions

    Science.gov (United States)

    Walker, R. D., Jr.

    1973-01-01

    Results of experiments on electron microscopy of fuel cell components, thermal decomposition of Teflon by thermogravimetry, surface area and pore size distribution measurements, water transport in fuel cells, and surface tension of KOH solutions are described.

  2. Intravascular catheter-related infection – current concepts

    African Journals Online (AJOL)

    2006-08-28

    Aug 28, 2006 ... prevented. ... blood from both the catheter and a peripheral site, may ... Given the important role of cutaneous microflora in the ... valvular heart disease (especially prosthetic valves) and ... be explained by high arterial flow around the catheter, ... vena cava or right atrium via the cephalic and basilar veins of ...

  3. Intrathecal Bupivacaine Monotherapy with a Retrograde Catheter for the Management of Complex Regional Pain Syndrome of the Lower Extremity.

    Science.gov (United States)

    McRoberts, W Porter; Apostol, Catalina; Haleem, Abdul

    2016-01-01

    Complex regional pain syndrome (CRPS) presents a therapeutic challenge due to its many presentations and multifaceted pathophysiology. There is no approved treatment algorithm and clinical interventions are often applied empirically. In cases of CRPS where symptoms are localized to an extremity, a targeted treatment is indicated. We describe the use of intrathecal bupivacaine monotherapy, delivered through a retrograde catheter, in the treatment of CRPS affecting the lower extremity. The patient, a 57-year-old woman with a history of failed foot surgery, was seen in our office after 2 years of ineffective treatments with local blocks and neurolytic procedures. We advanced therapy to moderately invasive procedures with an emphasis on neuromodulation. A combined central and peripheral stimulation technique that initially provided 75% pain relief, failed to provide lasting analgesia. We proceeded with an intrathecal pump implant. Based on the results of dorsal root ganglion (DRG) mapping, L5-S1 was identified as the optimal target for therapy and a retrograde catheter was placed at this level. Various intrathecal medications were tested individually. An intrathecal morphine trial was ineffective (visual analog scale [VAS] 7), while intrathecal clonidine provided excellent pain relief (VAS 0) that was limited by severe side effects. Bupivacaine provided 100% analgesia with tolerable side effects (lower extremity weakness and minor bladder incontinence) and was selected for intrathecal infusion. After 14 months, bupivacaine treatment continued to control pain exacerbations. We conclude that CRPS patients benefit from early identification of the predominant underlying symptoms and a targeted treatment with moderately invasive techniques when less invasive techniques fail. Intrathecal bupivacaine, bupivacaine monotherapy, retrograde catheter, complex regional pain syndrome (CRPS), dual stimulation, dosal root ganglion (DRG) testing.

  4. Early mechanism of action of arterially infused ethanol: an experimental study on the influence of infusion speed

    International Nuclear Information System (INIS)

    Han, Joon Koo

    1988-01-01

    Abdominal aortography and histopathologic examination after absolute ethanol infusion at fast (0.4cc/sec) and slow speed (0.04cc/sec) were performed on 16 rats (2 controls. 7 fast infusion group. 7 slow infusion group). Angiographic and histopathologic findings were correlated and the findings of slow and fast infusion groups were studied. The results are as follows: 1. Histopathologic findings of the fast infusion group revealed wide area of glomerular and tubular collapses, obliteration of the free space between the Bowmann's capsule and glomerulus, sloughing and loss of the endothelium, fresh thrombi attached to the wall, and cleavage of the muscle layer of the arteries. 2. Angiographic findings of the fast infusion group revealed luminal irregularity, early obstruction of the aorta and the renal arteries, and delayed circulation time. 3. Histopathologic findings of the slow infusion group revealed degenerated, coalesced red blood cell packed in the glomeruli, focal areas of severe glomerular and tubular damage on relatively normal background, endothelial and muscular damage of the arteries. 4. Angiographic findings of the slow infusion group revealed focal perfusion defect of the kidney, delayed circulation time, and mild luminal irregularity, but there was no obstruction of the major arteries. 5. In conclusion, author believes that endothelial damage and thrombus formation from the damaged vessel wall, as well as direct cytotoxicity and in situ emboli formation play a significant role in the embolic effect of absolute ethanol.

  5. Tunnel unroofing effectiveness in chronic peritoneal catheter infection

    Directory of Open Access Journals (Sweden)

    Lorena Carranza

    2017-04-01

    Full Text Available Introduction: Chronic catheter infection usually involves external Dacron cuff colonization, without its removal, antibiotic treatment proved ineffective. Catheter unroofing technique has been described as an alternative to peritoneal catheter removal. Material and methods: We analyzed the data from 13 patients retrospectively. Evolution after unroofing was evaluated, considering as treatment failure the appearance of new infection in the hole, tunnel or peritonitis associated to the same germ. Results: Between 1997-2014 years, unroofing was performed on 13 patients. Mean age-rate: 46.2 (IC 95%: 35.9 years – 56.5 years male sex 9, 69.23%. Germs: staphylococcus 7, pseudomona 2, polymicrobial 1, negative culture 3. Nine patiens healed: 69.2%; there was no statistical association among sex, age, microbiological result, previous hemodialysis use, type of catheter, surgical technique or with the surgeon who performed the procedure (p≥ 0.05. Discussion: Catheter removal implies transient transference to hemodialysis and new replacement surgery, although there is few experience with this technique, it could be an acceptable alternative, enabling a group of patients to continue with PD treatment. Conclusion: Unroofing technique proved to be beneficial in 69.2% of the cases (9 patients independently of the type of germ present, representing an acceptable treatment which avoids catheter removal, enabling the procedure to continue, and decreasing the need to employ more aggressive therapies.

  6. Balloon catheter dilatation in esophageal achalasia: long term follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Cheol Yong; Park, Hyun Mee; Kim, So Eun; Lee, Shin Hyung; Kim, Seung Hyeon; Lee, Chang Joon [National Medical Center, Seoul (Korea, Republic of)

    1994-12-15

    To evaluate the clinical efficacy of balloon catheter dilatation in the treatment of esophageal achalasia. Seven patients(three males and four females) with esopha-geal achalasia were treated with balloon catheter dilatation. Balloon catheters of variable sizes were used depending on patient's conditions. The patients were followed up over a period of 12-39 months. Balloon catheter dilatation in esophageal achalasia was successful in all patients without esophageal perforation. All patients were relieved from dysphagia. Recurrence was not found in 5 patients on long term follow-up study, but was seen in 2 patients after 18 and 21 months, respectively. Balloon catheter dilatation was a safe and effective method in the treatment of esophageal achalasia with low recurrence rate of 29% on follow-up study.

  7. Balloon catheter dilatation in esophageal achalasia: long term follow-up

    International Nuclear Information System (INIS)

    Shin, Cheol Yong; Park, Hyun Mee; Kim, So Eun; Lee, Shin Hyung; Kim, Seung Hyeon; Lee, Chang Joon

    1994-01-01

    To evaluate the clinical efficacy of balloon catheter dilatation in the treatment of esophageal achalasia. Seven patients(three males and four females) with esopha-geal achalasia were treated with balloon catheter dilatation. Balloon catheters of variable sizes were used depending on patient's conditions. The patients were followed up over a period of 12-39 months. Balloon catheter dilatation in esophageal achalasia was successful in all patients without esophageal perforation. All patients were relieved from dysphagia. Recurrence was not found in 5 patients on long term follow-up study, but was seen in 2 patients after 18 and 21 months, respectively. Balloon catheter dilatation was a safe and effective method in the treatment of esophageal achalasia with low recurrence rate of 29% on follow-up study

  8. Innovating urinary catheter design: An introduction to the engineering challenge.

    Science.gov (United States)

    Murphy, Cathy

    2018-05-01

    Every day, people around the world rely on intermittent and indwelling urinary catheters to manage bladder dysfunction, but the potential or actual harm caused by these devices is well-recognised. Current catheter designs can cause urinary tract infection and septicaemia, bladder and urethral trauma and indwelling devices frequently become blocked. Furthermore, the devices can severely disrupt users' lives, limiting their daily activities and can be costly to manage for healthcare providers. Despite this, little significant design innovation has taken place in the last 80 years. In this article current catheter designs and their limitations are reviewed, common catheter-associated problems are outlined and areas of design ripe for improvement proposed. The potential to relieve the individual and economic burden of catheter use is high.

  9. The dialysis catheter and infectious peritonitis in intermittent peritoneal dialysis

    DEFF Research Database (Denmark)

    Kolmos, Hans Jørn; Hemmeløff Andersen, Karl Erik; Hansen, Lise

    1984-01-01

    118 episodes of infectious peritonitis registered among 156 patients treated with intermittent peritoneal dialysis over a 5-yr period were analysed with special reference to potential routes of infection associated with the dialysis catheter. Peritonitis was randomly distributed among the patients......, and the change of keeping free of peritonitis declined exponentially with time. The main factor determining the individual number of episodes was the total space of time, in which a patient had been wearing a dialysis catheter, whereas the number of catheter disconnections played no significant role. A relative...... preponderance of cases due to Enterobacteriaceae was noted within the first week after catheter implantation. In contrast with this, peritonitis with skin microorganisms was not associated with the implantation of catheters....

  10. Catheter fracture of intravenous ports and its management.

    Science.gov (United States)

    Wu, Ching-Yang; Fu, Jui-Ying; Feng, Po-Hao; Kao, Tsung-Chi; Yu, Sheng-Yueh; Li, Hao-Jui; Ko, Po-Jen; Hsieh, Hung-Chang

    2011-11-01

    Intravenous ports are widely used for oncology patients. However, catheter fractures may lead to the need for re-intervention. We aimed to identify the risk factors associated with catheter fractures. Between January 1 and December 31, 2006, we retrospectively reviewed the clinical data and plain chest films of 1,505 patients implanted with an intravenous port at Chang Gung Memorial Hospital. Different vascular sites were compared using the chi-square or Fisher's exact test for categorical variables, and the t test was used for continuous variables with normal distribution; P port type Arrow French (Fr.) 8.1 (P port and catheter removal is recommended. Female gender, intravenous port implantation via the subclavian route, and the Arrow Fr. 8.1 port were found to be risk factors. Patients with these risk factors should be monitored closely to avoid catheter fractures.

  11. Two years experience with tunneled dialysis catheters in patients requiring haemodialysis

    International Nuclear Information System (INIS)

    Raheem, A.; Rana, A. I.; Ramzan, M.; Shah, R. A.; Mehmood, S. N.; Naseem, S.

    2014-01-01

    Objective: To look for survival rate and major reasons behind the failure of tunnelled dialysis catheters in patients on haemodialysis. Methods: The retrospective study was conducted at the Department of Interventional Radiology, Shifa International Hospital, Islamabad, and comprised records of 100 consecutive subjects from a list of patients in whom tunnelled cuffed catheters were placed from February 2009 to January 2011 and were followed up for two years. Data was collected on a proforma from the hospital database and medical records of patients. SPSS 19 was used for statistical analysis. Results: Of the total 122 catheters placed in 100 patients, 49(40.16%) were lost to follow-up. Of the remaining 73(59.83%) catheters, 38(52%) had achieved their desired function, while 35(48%) failed to achieve the target duration. Among the reasons of catheter failure, infection was the commonest at 13(37.14%) with infection rate of 0.24 per 1000 catheter days. According to Kaplan Meier analysis, catheter survival rates at 60, 90 and 180 days were 89%, 77% and 64% respectively. Mean effective duration of catheter was 129+-117 days. Conclusion: Tunnelled dialysis catheters can be safely used as vascular access till the maturation of fistula and may be an alternative to Arterio-Venous Fistula or graft for long-term vascular access if indicated. (author)

  12. An experimental study about efficacy of the drain catheters

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Bum Gyu; Nho, Joon Young; Woo, Hyo Cheol; Hwang, Woo Cheol; Park, Choong Ki; Yoon, Jong Sup [Hallym University College of Medicine, Seoul (Korea, Republic of)

    1993-09-15

    Although percutaneous abscess drainage has become and accepted alternative from of therapy for selected patients with abscess, it is well known that there are several factors in the failure of adequate drainage such as pre- and post-procedural management, technique itself, various features of abscess, and selection and application of catheters. Among these factors, we made an experiment about drainage efficacy of commonly used various catheters with different viscosities of water-glycerin solution under the two different pressure gradients. The experimental values of flow rate were very lower than the calculated values. An efficacy of experimental value was 4-14%. Because the inner diameter of fittings and stopcocks was usually smaller than the inner diameter of catheters, these factors also affected the drain efficacy. Finally, we thought that it will be very helpful to the treatment of patient as well as to study about the catheter drainage, if the drain efficacy of individual catheters has been notified.

  13. Vessel bifurcation localization based on intraoperative three-dimensional ultrasound and catheter path for image-guided catheter intervention of oral cancers.

    Science.gov (United States)

    Luan, Kuan; Ohya, Takashi; Liao, Hongen; Kobayashi, Etsuko; Sakuma, Ichiro

    2013-03-01

    We present a method to localize intraoperative target vessel bifurcations under bones for ultrasound (US) image-guided catheter interventions. A catheter path is recorded to acquire skeletons for the target vessel bifurcations that cannot be imaged by intraoperative US. The catheter path is combined with the centerlines of the three-dimensional (3D) US image to construct a preliminary skeleton. Based on the preliminary skeleton, the orientations of target vessels are determined by registration with the preoperative image and the bifurcations were localized by computing the vessel length. An accurate intraoperative vessel skeleton is obtained for correcting the preoperative image to compensate for vessel deformation. A reality check of the proposed method was performed in a phantom experiment. Reasonable results were obtained. The in vivo experiment verified the clinical workflow of the proposed method in an in vivo environment. The accuracy of the centerline length of the vessel for localizing the target artery bifurcation was 2.4mm. These results suggest that the proposed method can allow the catheter tip to stop at the target artery bifurcations and enter into the target arteries. This method can be applied for virtual reality-enhanced image-guided catheter intervention of oral cancers. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. 21 CFR 880.5725 - Infusion pump.

    Science.gov (United States)

    2010-04-01

    ... Infusion pump. (a) Identification. An infusion pump is a device used in a health care facility to pump fluids into a patient in a controlled manner. The device may use a piston pump, a roller pump, or a... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Infusion pump. 880.5725 Section 880.5725 Food and...

  15. Control of intravascular catheters using an array of active steering coils.

    Science.gov (United States)

    Gudino, N; Heilman, J A; Derakhshan, J J; Sunshine, J L; Duerk, J L; Griswold, M A

    2011-07-01

    To extend the concept of deflecting the tip of a catheter with the magnetic force created in an MRI system through the use of an array of independently controllable steering coils located in the catheter tip, and to present methods for visualization of the catheter and/or surrounding areas while the catheter is deflected. An array of steering coils made of 42-gauge wire was built over a 2.5 Fr (0.83 mm) fiber braided microcatheter. Two of the coils were 70 turn axial coils separated by 1 cm, and the third was a 15-turn square side coil that was 2 x 4 mm2. Each coil was driven independently by a pulse width modulation (PWM) current source controlled by a microprocessor that received commands from a MATLAB routine that dynamically set current amplitude and direction for each coil. The catheter was immersed in a water phantom containing 1% Gd-DTPA that was placed at the isocenter of a 1.5 T MRI scanner. Deflections of the catheter tip were measured from image-based data obtained with a real-time radio frequency (RF) spoiled gradient echo sequence (GRE). The small local magnetic fields generated by the steering coils were exploited to generate a hyperintense signal at the catheter tip by using a modified GRE sequence that did not include slice-select rewinding gradients. Imaging and excitation modes were implemented by synchronizing the excitation of the steering coil array with the scanner by ensuring that no current was driven through the coils during the data acquisition window; this allowed visualization of the surrounding tissue while not affecting the desired catheter position. Deflections as large as 2.5 cm were measured when exciting the steering coils sequentially with a 100 mA maximum current per coil. When exciting a single axial coil, the deflection was half this value with 30% higher current. A hyperintense catheter tip useful for catheter tracking was obtained by imaging with the modified GRE sequence. Clear visualization of the areas surrounding the

  16. Fecal containment in bedridden patients: economic impact of 2 commercial bowel catheter systems.

    Science.gov (United States)

    Kowal-Vem, Areta; Poulakidas, Stathis; Barnett, Barbara; Conway, Deborah; Culver, Daniel; Ferrari, Michelle; Potenza, Bruce; Koenig, Michael; Mah, John; Majewski, Mary; Morris, Linda; Powers, Jan; Stokes, Elizabeth; Tan, Michael; Salstrom, Sara-Jane; Zaletel, Cindy; Ambutas, Shirley; Casey, Kathleen; Stein, Jayne; DeSane, Mary; Berry, Kathy; Konz, Elizabeth C; Riemer, Michael R; Cullum, Malford E

    2009-05-01

    Fecal contamination is a major challenge in patients in acute/critical care settings that is associated with increased cost of care and supplies and with development of pressure ulcers, incontinence dermatitis, skin and soft tissue infections, and urinary tract infections. To assess the economic impact of fecal containment in bedridden patients using 2 different indwelling bowel catheters and to compare infection rates between groups. A multicenter, observational study was done at 12 US sites (7 that use catheter A, 5 that use catheter B). Patients were followed from insertion of an indwelling bowel catheter system until the patient left the acute/critical care unit or until 29 days after enrollment, whichever came first. Demographic data, frequency of bedding/dressing changes, incidence of infection, and Braden scores (risk of pressure ulcers) were recorded. The study included 146 bedridden patients (76 with catheter A, 70 with catheter B) who had similar Braden scores at enrollment. The rate of bedding/dressing changes per day differed significantly between groups (1.20 for catheter A vs 1.71 for catheter B; P = .004). According to a formula that accounted for personnel resources and laundry cycle costs, catheter A cost $13.94 less per patient per day to use than did catheter B. Catheter A was less likely than was catheter B to be removed during the observational period (P = .03). Observed infection rates were low. Catheter A may be more cost-effective than catheter B because it requires fewer unscheduled linen changes per patient day.

  17. Vascular Access Procedures

    Science.gov (United States)

    ... the catheter. top of page What are the benefits vs. risks? Benefits A central catheter permits infusion of solutions containing ... products may be given by this route, including antibiotics and blood products. The catheter also may be ...

  18. A pilot study to assess adductor canal catheter tip migration in a cadaver model.

    Science.gov (United States)

    Leng, Jody C; Harrison, T Kyle; Miller, Brett; Howard, Steven K; Conroy, Myles; Udani, Ankeet; Shum, Cynthia; Mariano, Edward R

    2015-04-01

    An adductor canal catheter may facilitate early ambulation after total knee arthroplasty, but there is concern over preoperative placement since intraoperative migration of catheters may occur from surgical manipulation and result in ineffective analgesia. We hypothesized that catheter type and subcutaneous tunneling may influence tip migration for preoperatively inserted adductor canal catheters. In a male unembalmed human cadaver, 20 catheter insertion trials were divided randomly into one of four groups: flexible epidural catheter either tunneled or not tunneled; or rigid stimulating catheter either tunneled or not tunneled. Intraoperative patient manipulation was simulated by five range-of-motion exercises of the knee. Distance and length measurements were performed by a blinded regional anesthesiologist. Changes in catheter tip to nerve distance (p = 0.225) and length of catheter within the adductor canal (p = 0.467) were not different between the four groups. Two of five non-tunneled stimulating catheters (40 %) were dislodged compared to 0/5 in all other groups (p = 0.187). A cadaver model may be useful for assessing migration of regional anesthesia catheters; catheter type and subcutaneous tunneling may not affect migration of adductor canal catheters based on this preliminary study. However, future studies involving a larger sample size, actual patients, and other catheter types are warranted.

  19. Percutaneous catheter drainage of intrapulmonary fluid collection

    International Nuclear Information System (INIS)

    Park, E. D.; Kim, H. J.; Choi, P. Y.; Jung, S. H.

    1994-01-01

    With the success of percutaneous abdominal abscess drainage, attention is now being focused on the use of similar techniques in the thorax. We studied to evaluate the effect of percutaneous drainage in parenchymal fluid collections in the lungs. We performed percutaneous drainage of abscesses and other parenchymal fluid collections of the lungs in 15 patients. All of the procedures were performed under the fluoroscopic guidance with an 18-gauge Seldinger needle and coaxial technique with a 8-10F drainage catheter. Among 10 patients with lung abscess, 8 patients improved by percutaneous catheter drainage. In one patient, drainage was failed by the accidental withdrawal of the catheter before complete drainage. One patient died of sepsis 5 hours after the procedure. Among three patients with complicated bulla, successful drainage was done in two patients, but in the remaining patient, the procedure was failed. In one patient with intrapulmonary bronchogenic cyst, the drainage was not successful due to the thick internal contents. In one patient with traumatic hematoma, after the drainage of old blood clots, the signs of infection disappeared. Overally, of 14 patients excluding one who died, 11 patients improved with percutaneous catheter drainage and three patients did not. There were no major complications during and after the procedure. We conclude that percutaneous catheter drainage is effective and safe procedure for the treatment of parenchymal fluid collections of the lung in patients unresponsive to the medical treatment

  20. Percutaneous catheter drainage of intrapulmonary fluid collection

    Energy Technology Data Exchange (ETDEWEB)

    Park, E. D.; Kim, H. J.; Choi, P. Y.; Jung, S. H. [Gyeongsang National University Hospital, Chinju (Korea, Republic of)

    1994-01-15

    With the success of percutaneous abdominal abscess drainage, attention is now being focused on the use of similar techniques in the thorax. We studied to evaluate the effect of percutaneous drainage in parenchymal fluid collections in the lungs. We performed percutaneous drainage of abscesses and other parenchymal fluid collections of the lungs in 15 patients. All of the procedures were performed under the fluoroscopic guidance with an 18-gauge Seldinger needle and coaxial technique with a 8-10F drainage catheter. Among 10 patients with lung abscess, 8 patients improved by percutaneous catheter drainage. In one patient, drainage was failed by the accidental withdrawal of the catheter before complete drainage. One patient died of sepsis 5 hours after the procedure. Among three patients with complicated bulla, successful drainage was done in two patients, but in the remaining patient, the procedure was failed. In one patient with intrapulmonary bronchogenic cyst, the drainage was not successful due to the thick internal contents. In one patient with traumatic hematoma, after the drainage of old blood clots, the signs of infection disappeared. Overally, of 14 patients excluding one who died, 11 patients improved with percutaneous catheter drainage and three patients did not. There were no major complications during and after the procedure. We conclude that percutaneous catheter drainage is effective and safe procedure for the treatment of parenchymal fluid collections of the lung in patients unresponsive to the medical treatment.

  1. A Comparison of the Effects of Intraosseous and Intravenous 5% Albumin on Infusion Time and Hemodynamic Measures in a Swine Model of Hemorrhagic Shock.

    Science.gov (United States)

    Muir, Stacy L; Sheppard, Lance B; Maika-Wilson, Anne; Burgert, James M; Garcia-Blanco, Jose; Johnson, Arthur D; Coyner, Jennifer L

    2016-08-01

    Introduction Obtaining intravenous (IV) access in patients in hemorrhagic shock is often difficult and prolonged. Failed IV attempts delay life-saving treatment. Intraosseous (IO) access may often be obtained faster than IV access. Albumin (5%) is an option for prehospital volume expansion because of the absence of interference with coagulation and platelet function. Hypothesis/Problem There are limited data comparing the performance of IO and IV administered 5% albumin. The aims of this study were to compare the effects of tibial IO (TIO) and IV administration of 500 mL of 5% albumin on infusion time and hemodynamic measurements of heart rate (HR), mean arterial pressure (MAP), cardiac output (CO), and stroke volume (SV) in a swine model of hemorrhagic shock. Sixteen male swine were divided into two groups: TIO and IV. All subjects were anesthetized and a Class III hemorrhage was achieved by exsanguination of 31% of estimated blood volume (EBV) from a femoral artery catheter. Following exsanguination, 500 mL of 5% albumin was administered under pressurized infusion (300 mmHg) by the TIO or IV route and infusion time was recorded. Hemodynamic measurements of HR, MAP, CO, and SV were collected before and after exsanguination and every 20 seconds for 180 seconds during 5% albumin infusion. An independent t-test determined that IV 5% albumin infusion was significantly faster compared to IO (P=.01). Mean infusion time for TIO was seven minutes 35 seconds (SD=two minutes 44 seconds) compared to four minutes 32 seconds (SD=one minute 08 seconds) in the IV group. Multivariate Analysis of Variance was performed on hemodynamic data collected during the 5% albumin infusion. Analyses indicated there were no significant differences between the TIO and IV groups relative to MAP, CO, HR, or SV (P>.05). While significantly longer to infuse 5% albumin by the TIO route, the longer TIO infusion time may be negated as IO devices can be placed more quickly compared to repeated IV

  2. [A Case of HPN, In Which QOL Improvement Was Achieved by Combining Continuous Infusion with Once-Weekly Intermittent Infusion - Contribution of Pharmacists to Health Promotion among Home Patients Receiving Infusion Therapy].

    Science.gov (United States)

    Takeda, Namihiro; Hamana, Tomoko; Oka, Toyoka; Hirohara, Masayoshi; Kushida, Kazuki

    2016-12-01

    Patients receiving parenteral nutrition at home have the following two options: 24-h continuous or intermittent infusion. To date, for patients with impaired glucose tolerance and/or other metabolic disorders or for those with decreased cardiac/ pulmonary/renal function, it is desirable to opt for continuous infusion to minimize the variance in the body's metabolic rate as much as possible. Furthermore, it should be noted that continuous infusion evokes a stronger feeling among patients of being constrained because it restricts their everyday activities. This case witnesses collaborations among the patient's doctor, dispensary's pharmacy, and patient's family. Because ofthe use ofintermittent infusion more or less once per week in addition to continuous infusion, significant improvement in quality of life was achieved, and the patient was able to enjoy taking a short trip. To assist a home patient receiving infusion therapy, it is essential that the pharmacist be equipped with skills to manage risks associated with infusion therapy and have knowledge about insurance to cover incidents concerning infusion fluids or medical materials. It will certainly depend on the degree ofindependence ofpatients and the level ofcare their families can provide; however, should we manage to use a similar medical procedure in at least a few cases in the future, we may be able to contribute to "joie de vivre" in home patients receiving infusion therapy.

  3. Dialysis catheter-related superior vena cava syndrome with patent vena cava: Long term efficacy of unilateral viatorr stent-graft avoiding catheter manipulation

    Energy Technology Data Exchange (ETDEWEB)

    Quaretti, Pietro; Galli, Franco; Maramarco, Lorenzo Paplo; Corti, Riccardo; Leati, Giovanni; Fiorina, Ilaria; Maestri, Marcello [IRCCS Policlinico San Matteo Foundation, Pavia (Italy)

    2014-06-15

    Central venous catheters are the most frequent causes of benign central vein stenosis. We report the case of a 79-year-old woman on hemodialysis through a twin catheter in the right internal jugular vein, presenting with superior vena cava (SVC) syndrome with patent SVC. The clinically driven endovascular therapy was conducted to treat the venous syndrome with a unilateral left brachiocephalic stent-graft without manipulation of the well-functioning catheter. The follow-up was uneventful until death 94 months later.

  4. Dialysis catheter-related superior vena cava syndrome with patent vena cava: Long term efficacy of unilateral viatorr stent-graft avoiding catheter manipulation

    International Nuclear Information System (INIS)

    Quaretti, Pietro; Galli, Franco; Maramarco, Lorenzo Paplo; Corti, Riccardo; Leati, Giovanni; Fiorina, Ilaria; Maestri, Marcello

    2014-01-01

    Central venous catheters are the most frequent causes of benign central vein stenosis. We report the case of a 79-year-old woman on hemodialysis through a twin catheter in the right internal jugular vein, presenting with superior vena cava (SVC) syndrome with patent SVC. The clinically driven endovascular therapy was conducted to treat the venous syndrome with a unilateral left brachiocephalic stent-graft without manipulation of the well-functioning catheter. The follow-up was uneventful until death 94 months later.

  5. Multiple Coaxial Catheter System for Reliable Access in Interventional Stroke Therapy

    International Nuclear Information System (INIS)

    Kulcsar, Zsolt; Yilmaz, Hasan; Bonvin, Christophe; Lovblad, Karl O.; Ruefenacht, Daniel A.

    2010-01-01

    In some patients with acute cerebral vessel occlusion, navigating mechanical thrombectomy systems is difficult due to tortuous anatomy of the aortic arch, carotid arteries, or vertebral arteries. Our purpose was to describe a multiple coaxial catheter system used for mechanical revascularization that helps navigation and manipulations in tortuous vessels. A triple or quadruple coaxial catheter system was built in 28 consecutive cases presenting with acute ischemic stroke. All cases were treated by mechanical thrombectomy with the Penumbra System. In cases of unsuccessful thrombo-aspiration, additional thrombolysis or angioplasty with stent placement was used for improving recanalization. The catheter system consisted of an outermost 8-Fr and an intermediate 6-Fr guiding catheter, containing the inner Penumbra reperfusion catheters. The largest, 4.1-Fr, reperfusion catheter was navigated over a Prowler Select Plus microcatheter. The catheter system provided access to reach the cerebral lesions and provided stability for the mechanically demanding manipulations of thromboaspiration and stent navigation in all cases. Apart from their mechanical role, the specific parts of the system could also provide access to different types of interventions, like carotid stenting through the 8-Fr guiding catheter and intracranial stenting and thrombolysis through the Prowler Select Plus microcatheter. In this series, there were no complications related to the catheter system. In conclusion, building up a triple or quadruple coaxial system proved to be safe and efficient in our experience for the mechanical thrombectomy treatment of acute ischemic stroke.

  6. Septic Thrombophlebitis of the Cephalic Vein Caused by a Peripherally Inserted Venous Catheter

    Directory of Open Access Journals (Sweden)

    M Mirmohammadsadeghi

    2005-07-01

    Full Text Available Septic thrombophlebitis of a vein is a rare but life-threatening complication of an intravascular (IV catheter placed percutaneously in the veins. Most published clinical experiences with IV catheters, mainly in the outpatient settings, have reported very low rates of catheter-related bloodstream infection compared to rates with central venous catheters placed in a subclavian or internal jugular vein. Most of the complications reported with IV catheters have been non-infectious, particularly sterile phlebitis or thrombosis. We report a case of cephalic vein suppurative thrombophlebitis from an intravascular catheter and offer guidelines for diagnosis and management of this complication. Key words: Septic thrombophlebitis, Intravascular catheter, Suppurative thrombophlebitis

  7. Radiologic interventional retrieval of retained central venous catheter fragment in prematurity: case report

    International Nuclear Information System (INIS)

    Park, Jee Won; Jo, Jung Hyun; Park, Byeong Ho

    2007-01-01

    The fracture of a central venous catheter is a rare but potentially serious complication. Moreover, removal of the broken catheter pieces is considerably challenging, especially for premature infants. We report 3 case studies of the percutaneous transcatheter retrieval of broken catheter parts in 3 premature infants. We confirmed the location of the catheter fragments via a DSA venogram with diluted contrast media. Using the minimum amount of contrast, and extreme caution, we made certain no contrast-induced nephrotoxicity of air embolism occurred during catheter manipulation. In addition, when the broken fragment was curled or attached to the cardiac wall, we used a hook-shaped catheter to facilitate the capturing of the catheter with a loopsnare. This report demonstrates the feasibility of removing a retained catheter fragment in a premature infant using a percutaneous transcatheter approach

  8. Infusion-related reactions to infliximab in patients with rheumatoid arthritis in a clinical practice setting: relationship to dose, antihistamine pretreatment, and infusion number.

    Science.gov (United States)

    Wasserman, Michael J; Weber, Deborah A; Guthrie, Judith A; Bykerk, Vivian P; Lee, Peter; Keystone, Edward C

    2004-10-01

    We describe infusion-related reactions to infliximab (during infusion or within 1 hour postinfusion) in patients with active rheumatoid arthritis (RA) treated in a quaternary care center. We followed 113 patients for a mean of 60.6 +/- 28.9 weeks, obtaining 10.5 +/- 4.9 infusions per patient. We observed 1183 infusions resulting in 104 infusion reactions (8.8%). All reactions resolved within several hours following cessation of the infusion and none was serious enough to warrant hospitalization. Reactions included allergic reactions (pruritus, urticaria) in 4.2% of infusions, cardiopulmonary (hypotension, hypertension, tachycardia) in 3.0%, and miscellaneous reactions (headache, nausea, vomiting) in 2.0%. Reactions occurred in 8.0% of 3 mg/kg infusions and in 10.3% of 5 mg/kg infusions. Reactions occurred in 13.2% of infusions that involved antihistamine pretreatment compared to only 7.5% of infusions that involved no pretreatment. At both infliximab doses, there was a similar frequency of infusion reactions in patients pretreated due to a previous infusion (12.6%) compared to those pretreated strictly based on infusion number (14.7%). A number of the reactions involving antihistamine pretreatment may be explained by known side effects of diphenhydramine, including headache, dizziness, nausea, and palpitations. Infusion-related reactions to infliximab were infrequent, rarely severe, and easily manageable. The frequency of reactions was equivalent in patients treated with 3 mg/kg compared to 5 mg/kg. Reactions were significantly more frequent in infusions where patients were pretreated with the antihistamine diphenhydramine, compared to those not involving pretreatment.

  9. Daily concurrent preoperative chemoradiotherapy using superselective intra-arterial infusion via superficial temporal artery for advanced oral cancer. Histological evaluation of metastatic cervical lymph nodes

    International Nuclear Information System (INIS)

    Mitsudo, Kenji; Yamamoto, Noriyuki; Shigetomi, Toshio

    2010-01-01

    Superselective intra-arterial chemotherapy via a superficial temporal artery has become feasible for daily concurrent radiotherapy and chemotherapy in patients with oral cancer. In this study, histopathological effects on metastatic cervical lymph nodes in cases of advanced oral cancer using superselective intra-arterial chemoradiotherapy were evaluated. Thirty-seven oral cancer patients with cervical lymph node metastasis were treated with preoperative chemoradiotherapy using superselective intra-arterial infusion via the superficial temporal artery. The treatment consisted of superselective intra-arterial infusions (docetaxel, total 60 mg/m 2 ; cisplatin, total 100-150 mg/m 2 ) and concurrent radiotherapy (total 40-60 Gy) for 4-6 weeks, followed by surgery. In cases in which the catheter was inserted into the facial artery, grade III or IV (Oboshi-Shimosato classification) in the cervical lymph node metastasis was obtained in 20 (83.3%) of 24 patients. And, forty-six (88.5%) of 52 metastatic lymph nodes showed grade III or IV. This method was an effective regimen for oral cancer with cervical lymph node metastasis. (author)

  10. Catheter Closure Through a Venous Approach of Patent Ductus Arteriosus in Small Pediatric Patients Using Combined Angiographic and Echocardiographic Guidance.

    Science.gov (United States)

    Thanopoulos, Basil Vasilios D; Ninios, Vlassis; Dardas, Petros; Giannopoulos, Andreas; Deleanou, Dan; Iancovici, Silvia

    2016-11-15

    The standard technique of catheter closure of patent ductus arteriosus (PDA) may be associated with arterial complications particularly in small pediatric patients. The aim of this study was to evaluate whether catheter closure of PDA in small children using an exclusive venous approach is a safe and effective alternative to closure with the standard technique. One hundred-twelve patients, aged 2 to 24 months, were randomly assigned in a 1:1 ratio to catheter closure of PDA using the standard technique (group 1) and an exclusive venous approach (group 2), respectively. In group 2, the procedure was guided using hand injections of contrast media through the delivery sheath and 2-dimensional and color Doppler echocardiography. Group 1: the PDA diameter ranged from 2 to 5.5 mm and the device diameter ranged from 4 to 8 mm. The PDA occluders were permanently implanted in all patients. Five losses of the arterial pulses that were restored with intravenous infusion of heparin and recombinant tissue plasminogen activator (rtPA), and 4 groin hematomas were the main complications of the procedure. Group 2: the mean PDA diameter ranged from 2.5 to 6 mm and the device diameter ranged from 3 to 8 mm. The PDA occluders were permanently implanted in all but 2 patients. There were no complications. Complete echocardiographic closure of PDA at 1-month follow-up was observed in all 110 patients. Exclusive transvenous PDA occlusion is an effective and safe technique that prevents the arterial complications of the standard approach in small children. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Extended infusion versus intermittent infusion of imipenem in the treatment of ventilator-associated pneumonia.

    Science.gov (United States)

    Ibrahim, Mohamed M; Tammam, Tarek Fouad; Ebaed, Mohy El Deen; Sarhan, Hatem A; Gad, Gamal F; Hussein, Amal K

    2017-01-01

    Mechanical ventilation support can be the main source of ventilator-associated pneumonia (VAP). VAP is a serious infection that may be associated with dangerous gram-negative bacteria mainly, and it leads to an increase in the mortality in the intensive care unit (ICU). Imipenem is one of the strongest antibiotics now available for treating VAP which is associated with gram-negative and gram-positive bacteria, and it belongs to beta-lactam antibiotic group (carbapenem). This study tried to investigate the efficacy of imipenem against VAP when it was infused within 180 min versus the efficacy when it was infused within 30-60 min. This study was conducted in main ICU in general hospital which consists of surgical and medical beds within 2 years. One hundred and eighty-seven patients were enrolled on it. This study is a retrospective cohort which was conducted within 2 years. The efficacy of imipenem which was administered by intermittent infusion (30-60 min) within first year was compared with the efficacy of imipenem which was administered by extended infusion (180 min) within second year in the field of VAP curing and cost reduction. All data were collected retrospectively from patient medical files and were statistically analyzed by SPSS version 20. The study was designed to measure clinical and cost reduction outcomes, mortality and hospital stay. The results indicated that there is a significant decrease in mortality, number of recurrent infection, and ICU stay length, and the number of mechanical ventilator days was associated with extended imipenem infusion during the second year of the study. The use of imipenem with extended infusion over 3 hours enhances its clinical outcomes in the treatment of VAP.

  12. Foley Catheter versus Vaginal Misoprostol for Labour Induction

    Directory of Open Access Journals (Sweden)

    Nasreen Noor

    2015-01-01

    Full Text Available Objectives. To compare the efficacy and safety of intravaginal misoprostol with transcervical Foley catheter for labour induction. Material and Methods. One hundred and four women with term gestation, with Bishop score < 4, and with various indications for labour induction were randomly divided into two groups. In Group I, 25 μg of misoprostol tablet was placed intravaginally, 4 hourly up to maximum 6 doses. In Group II, Foley catheter 16F was placed through the internal os of the cervix under aseptic condition and then inflated with 50 cc of sterile saline. Statistical analysis was done using SPSS software. Results. The induction to delivery interval was 14.03 ± 7.61 hours versus 18.40 ± 8.02 hours (p<0.01. The rate of vaginal delivery was 76.7% versus 56.8% in misoprostol and transcervical Foley catheter group, respectively. Uterine hyperstimulation was more common with misoprostol. Neonatal outcome was similar in both the groups. Conclusion. Intravaginal misoprostol is associated with a shorter induction to delivery interval as compared to Foley’s catheter and it increases the rate of vaginal delivery in cases of unripe cervix at term. Transcervical Foley catheter is associated with a lower incidence of uterine hyperstimulation during labour.

  13. Understanding Infusion Pumps.

    Science.gov (United States)

    Mandel, Jeff E

    2018-04-01

    Infusion systems are complicated electromechanical systems that are used to deliver anesthetic drugs with moderate precision. Four types of systems are described-gravity feed, in-line piston, peristaltic, and syringe. These systems are subject to a number of failure modes-occlusion, disconnection, siphoning, infiltration, and air bubbles. The relative advantages of the various systems and some of the monitoring capabilities are discussed. A brief example of the use of an infusion system during anesthetic induction is presented. With understanding of the functioning of these systems, users may develop greater comfort.

  14. The use of peridural catheter in the treatment of chronic malignant pain in the abdomen: Case report (peridural catheter in the treatment chronic pain

    Directory of Open Access Journals (Sweden)

    Palibrk Ivan

    2017-01-01

    Full Text Available Introduction: Chronic pain in the abdomen occurs as a consequence of malignancy in these parts of the body, surgical, of radiological and chemotherapy treatments. It may also be as a result of relapse of the basic process. Non-invasive therapy of oral and transdermal analgesic was successful for some time, where necessary applies and epidural catheter. Case Report: The patient had a diagnosis of chronic postoperative pain malignant etiology. He is already used transdermal fentanyl and Nonsteroidal Anti-Inflammatory Drugs, but without success (VAS score 8-10. We increased doses of analgesics, but without success. In order of pain therapy, peridural catheter placed in the level L3 - L4. 5 ml of a solution of 8 ml of 0.25% bupivacaine, 2 ml (100 micrograms of fentanyl and 10 ml of saline was administered every 6 hours through epidural catheter. The former chronic non-invasive treatment of pain did not stop. The first three to five days of pain relief was quite satisfactory in this way. Then the pain intensified but the peridural catheter had to be removed due to local infection. New peridural catheter was placed in the level L2 -L3. Then, 5 ml of the solution: of 8 ml 0,25% bupivacaine, 2 ml (100 micrograms of fentanyl and 10 ml of saline is administered through peridural catheter. Peridural catheter was total used for 45 days. We had a need for more and more frequently administering analgesics through a catheter during use. The patient was using transdermal fentanyl and Nonsteroidal Anti-Inflammatory Drugs, all the time. The patient soon died due to progression of the underlying disease. Conclusion: After long-term administration of opioids, it is necessary to change the type and route of administration of the drug to achieve the success of the therapy. In this case it was the use of analgesics and local anesthetics through the peridural catheter.

  15. Hemodialysis Catheter Heat Transfer for Biofilm Prevention and Treatment.

    Science.gov (United States)

    Richardson, Ian P; Sturtevant, Rachael; Heung, Michael; Solomon, Michael J; Younger, John G; VanEpps, J Scott

    2016-01-01

    Central line-associated bloodstream infections (CLABSIs) are not easily treated, and many catheters (e.g., hemodialysis catheters) are not easily replaced. Biofilms (the source of infection) on catheter surfaces are notoriously difficult to eradicate. We have recently demonstrated that modest elevations of temperature lead to increased staphylococcal susceptibility to vancomycin and significantly soften the biofilm matrix. In this study, using a combination of microbiological, computational, and experimental studies, we demonstrate the efficacy, feasibility, and safety of using heat as an adjuvant treatment for infected hemodialysis catheters. Specifically, we show that treating with heat in the presence of antibiotics led to additive killing of Staphylococcus epidermidis with similar trends seen for Staphylococcus aureus and Klebsiella pneumoniae. The magnitude of temperature elevation required is relatively modest (45-50°C) and similar to that used as an adjuvant to traditional cancer therapy. Using a custom-designed benchtop model of a hemodialysis catheter, positioned with tip in the human vena cava as well as computational fluid dynamic simulations, we demonstrate that these temperature elevations are likely achievable in situ with minimal increased in overall blood temperature.

  16. Infection and natural history of emergency department-placed central venous catheters.

    Science.gov (United States)

    LeMaster, Christopher H; Schuur, Jeremiah D; Pandya, Darshan; Pallin, Daniel J; Silvia, Jennifer; Yokoe, Deborah; Agrawal, Ashish; Hou, Peter C

    2010-11-01

    Central line-associated bloodstream infection (CLABSI, hereafter referred to in this paper as "bloodstream infection") is a leading cause of hospital-acquired infection. To our knowledge, there are no previously published studies designed to determine the rate of bloodstream infection among central venous catheters placed in the emergency department (ED). We design a retrospective chart review methodology to determine bloodstream infection and duration of catheterization for central venous catheters placed in the ED. Using hospital infection control, administrative, and ED billing databases, we identified patients with central venous catheters placed in the ED between January 1, 2007, and December 31, 2008, at one academic, urban ED with an annual census of 57,000. We performed a structured, explicit chart review to determine duration of catheterization and confirm bloodstream infection. We screened 4,251 charts and identified 656 patients with central venous catheters inserted in the ED, 3,622 catheter-days, and 7 bloodstream infections. The rate of bloodstream infection associated with central venous catheters placed in the ED was 1.93 per 1,000 catheter-days (95% confidence interval 0.50 to 3.36). The mean duration of catheterization was 5.5 days (median 4; range 1 to 29 days). Among infected central venous catheters, the mean duration of catheterization was 8.6 days (median 7; range 2 to 19 days). A total of 667 central venous catheters were placed in the internal jugular (392; 59%), subclavian (145; 22%), and femoral (130; 19%) veins. The sensitivity of using ED procedural billing code for identifying ED-placed central venous catheters among patients subsequently admitted to any ICU was 74.9% (95% confidence interval 71.4% to 78.3%). The rate of ED bloodstream infection at our institution is similar to current rates in ICUs. Central venous catheters placed in the ED remain in admitted patients for a substantial period. Copyright © 2010 American College of

  17. Prostate HDR brachytherapy catheter displacement between planning and treatment delivery

    International Nuclear Information System (INIS)

    Whitaker, May; Hruby, George; Lovett, Aimee; Patanjali, Nitya

    2011-01-01

    Background and purpose: HDR brachytherapy is used as a conformal boost for treating prostate cancer. Given the large doses delivered, it is critical that the volume treated matches that planned. Our outpatient protocol comprises two 9 Gy fractions, two weeks apart. We prospectively assessed catheter displacement between CT planning and treatment delivery. Materials and methods: Three fiducial markers and the catheters were implanted under transrectal ultrasound guidance. Metal marker wires were inserted into 4 reference catheters before CT; marker positions relative to each other and to the marker wires were measured from the CT scout. Measurements were repeated immediately prior to treatment delivery using pelvic X-ray with marker wires in the same reference catheters. Measurements from CT scout and film were compared. For displacements of 5 mm or more, indexer positions were adjusted prior to treatment delivery. Results: Results are based on 48 implants, in 25 patients. Median time from planning CT to treatment delivery was 254 min (range 81–367 min). Median catheter displacement was 7.5 mm (range −2.9–23.9 mm), 67% of implants had displacement of 5 mm or greater. Displacements were predominantly caudal. Conclusions: Catheter displacement can occur in the 1–3 h between the planning CT scan and treatment. It is recommended that departments performing HDR prostate brachytherapy verify catheter positions immediately prior to treatment delivery.

  18. Detection of electrophysiology catheters in noisy fluoroscopy images

    NARCIS (Netherlands)

    Franken, E.M.; Rongen, P.M.J.; Almsick, van M.A.; Haar Romenij, ter B.M.

    2006-01-01

    Cardiac catheter ablation is a minimally invasive medical procedure to treat patients with heart rhythm disorders. It is useful to know the positions of the catheters and electrodes during the intervention, e.g. for the automatization of cardiac mapping. Our goal is therefore to develop a robust

  19. Swelling and infusion of tea in tea bags.

    Science.gov (United States)

    Yadav, Geeta U; Joshi, Bhushan S; Patwardhan, Ashwin W; Singh, Gurmeet

    2017-07-01

    The present study deals with swelling and infusion kinetics of tea granules in tea bags. The swelling and infusion kinetics of tea bags differing in tea loading and tea bag shapes were compared with loose tea. Increment in temperature and dipping frequency of tea bag in hot water increased the infusion kinetics of tea bags. Reduction in particle size enhanced the swelling and infusion kinetics of tea in a tea bag. The effects of tea particle size, tea bag dipping rate, loading of tea granules in tea bag and tea bag shapes on infusion kinetics were investigated. Increase in tea loading in tea bags resulted in reduced infusion kinetics. Double chambered tea bag showed the highest swelling (30%) and infusion kinetics (8.30% Gallic acid equivalence) while single chambered tea bags showed the lowest kinetics, amongst the various bags studied. The swelling and infusion kinetics of loose tea was always faster and higher than that of tea bags. It was found that overall effect of percentage filling of tea granules and height of tea bed in a tea bag affects tea infusion kinetics the most. Weibull model was found to be in good agreement with the swelling data.

  20. Development of a force-reflecting robotic platform for cardiac catheter navigation.

    Science.gov (United States)

    Park, Jun Woo; Choi, Jaesoon; Pak, Hui-Nam; Song, Seung Joon; Lee, Jung Chan; Park, Yongdoo; Shin, Seung Min; Sun, Kyung

    2010-11-01

    Electrophysiological catheters are used for both diagnostics and clinical intervention. To facilitate more accurate and precise catheter navigation, robotic cardiac catheter navigation systems have been developed and commercialized. The authors have developed a novel force-reflecting robotic catheter navigation system. The system is a network-based master-slave configuration having a 3-degree of freedom robotic manipulator for operation with a conventional cardiac ablation catheter. The master manipulator implements a haptic user interface device with force feedback using a force or torque signal either measured with a sensor or estimated from the motor current signal in the slave manipulator. The slave manipulator is a robotic motion control platform on which the cardiac ablation catheter is mounted. The catheter motions-forward and backward movements, rolling, and catheter tip bending-are controlled by electromechanical actuators located in the slave manipulator. The control software runs on a real-time operating system-based workstation and implements the master/slave motion synchronization control of the robot system. The master/slave motion synchronization response was assessed with step, sinusoidal, and arbitrarily varying motion commands, and showed satisfactory performance with insignificant steady-state motion error. The current system successfully implemented the motion control function and will undergo safety and performance evaluation by means of animal experiments. Further studies on the force feedback control algorithm and on an active motion catheter with an embedded actuation mechanism are underway. © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  1. Performance evaluation of a robot-assisted catheter operating system with haptic feedback.

    Science.gov (United States)

    Song, Yu; Guo, Shuxiang; Yin, Xuanchun; Zhang, Linshuai; Hirata, Hideyuki; Ishihara, Hidenori; Tamiya, Takashi

    2018-06-20

    In this paper, a novel robot-assisted catheter operating system (RCOS) has been proposed as a method to reduce physical stress and X-ray exposure time to physicians during endovascular procedures. The unique design of this system allows the physician to apply conventional bedside catheterization skills (advance, retreat and rotate) to an input catheter, which is placed at the master side to control another patient catheter placed at the slave side. For this purpose, a magnetorheological (MR) fluids-based master haptic interface has been developed to measure the axial and radial motions of an input catheter, as well as to provide the haptic feedback to the physician during the operation. In order to achieve a quick response of the haptic force in the master haptic interface, a hall sensor-based closed-loop control strategy is employed. In slave side, a catheter manipulator is presented to deliver the patient catheter, according to position commands received from the master haptic interface. The contact forces between the patient catheter and blood vessel system can be measured by designed force sensor unit of catheter manipulator. Four levels of haptic force are provided to make the operator aware of the resistance encountered by the patient catheter during the insertion procedure. The catheter manipulator was evaluated for precision positioning. The time lag from the sensed motion to replicated motion is tested. To verify the efficacy of the proposed haptic feedback method, the evaluation experiments in vitro are carried out. The results demonstrate that the proposed system has the ability to enable decreasing the contact forces between the catheter and vasculature.

  2. Catheter Removal versus Retention in the Management of Catheter-Associated Enterococcal Bloodstream Infections

    Directory of Open Access Journals (Sweden)

    Jonas Marschall

    2013-01-01

    Full Text Available BACKGROUND: Enterococci are an important cause of central venous catheter (CVC-associated bloodstream infections (CA-BSI. It is unclear whether CVC removal is necessary to successfully manage enterococcal CA-BSI.

  3. Cost-effectiveness of a central venous catheter care bundle.

    Directory of Open Access Journals (Sweden)

    Kate A Halton

    Full Text Available BACKGROUND: A bundled approach to central venous catheter care is currently being promoted as an effective way of preventing catheter-related bloodstream infection (CR-BSI. Consumables used in the bundled approach are relatively inexpensive which may lead to the conclusion that the bundle is cost-effective. However, this fails to consider the nontrivial costs of the monitoring and education activities required to implement the bundle, or that alternative strategies are available to prevent CR-BSI. We evaluated the cost-effectiveness of a bundle to prevent CR-BSI in Australian intensive care patients. METHODS AND FINDINGS: A Markov decision model was used to evaluate the cost-effectiveness of the bundle relative to remaining with current practice (a non-bundled approach to catheter care and uncoated catheters, or use of antimicrobial catheters. We assumed the bundle reduced relative risk of CR-BSI to 0.34. Given uncertainty about the cost of the bundle, threshold analyses were used to determine the maximum cost at which the bundle remained cost-effective relative to the other approaches to infection control. Sensitivity analyses explored how this threshold alters under different assumptions about the economic value placed on bed-days and health benefits gained by preventing infection. If clinicians are prepared to use antimicrobial catheters, the bundle is cost-effective if national 18-month implementation costs are below $1.1 million. If antimicrobial catheters are not an option the bundle must cost less than $4.3 million. If decision makers are only interested in obtaining cash-savings for the unit, and place no economic value on either the bed-days or the health benefits gained through preventing infection, these cost thresholds are reduced by two-thirds. CONCLUSIONS: A catheter care bundle has the potential to be cost-effective in the Australian intensive care setting. Rather than anticipating cash-savings from this intervention, decision

  4. More than just a urinary catheter — Haemorrhage control by using a Foley catheter in a penetrating aortic root injury

    Directory of Open Access Journals (Sweden)

    Adel Elmoghrabi

    2016-08-01

    Full Text Available The prevalence of great vessel injuries in thoracic trauma is reported at 0.3–10%, predominantly due to a penetrating mechanism. Thoracic aortic injuries, more specifically those within proximity of the aortic root are challenging to manage and unceasing bleeding hampers adequate visualisation for performing repair. We report a case of a 31-year-old male that presented to the emergency department 1 h after sustaining a stab wound injury within proximity of the left upper sternal border. Vital signs were stable on presentation. Physical examination revealed a 1.5 cm laceration in the 3rd intercostal space. Chest X-ray revealed a small left pneumothorax, FAST scan was negative, and CT of the chest revealed left sided haemopneumothorax and haemopericardium. The patient was emergently transferred to the operating room where median thoracotomy was performed. A significant amount of bleeding was observed originating from a 1 cm laceration of the aortic root. Bleeding was controlled using a Foley catheter after unsuccessful attempts of digital compression, and the laceration was repaired using pledgeted sutures. Postoperative echocardiography and CT scan of the chest revealed normal cardiac functions with resolution of haemopericardium and haemopneumothorax, and the patient was discharged in a stable condition. High index of suspicion should be maintained for injury to the great vessels in patients with penetrating chest injuries, despite apparent haemodynamic stability. In this case, balloon tamponade using a Foley catheter served as a quick and simple technique that resulted in an almost bloodless field, facilitating adequate visualisation for definitive repair. Although the use of this technique has been previously described, this report serves as a reminder that a Foley catheter can be successfully used for balloon catheter tamponade in injuries to the aortic root. Keywords: Aortic root, Injury, Foley's catheter, Balloon catheter, Aorta

  5. CaSO4: Dy + Teflon dosimetric pellets for X, beta and gamma radiation detection

    International Nuclear Information System (INIS)

    Campos, L.L.; Lima, M.F.

    1987-08-01

    CaSO 4 : Dy + TEFLON dosimetric pellets with high sensitivity and low cost for X, beta and gamma radiation monitoring were studied and developed by the Dosimetric Material Production Laboratory of the Radiological Protection Departament and are disposable for sale. The thickness of the pellets are suitable for X, beta and gamma radiation measurements. The dosimetric properties of these pellets were determined and presented in this work. The results show the usefulness of 0,20mm thick pellets for beta radiation monitoring and 0,80mm thick pellets for x and gamma radiation detection. (Author) [pt

  6. Needle catheter duodenostomy: a technique for duodenal alimentation of birds.

    Science.gov (United States)

    Goring, R L; Goldman, A; Kaufman, K J; Roberts, C; Quesenberry, K E; Kollias, G V

    1986-11-01

    A technique for duodenal alimentation (needle catheter duodenostomy) of birds was developed, using the domestic pigeon (Columba livia) as the experimental model. A needle catheter was inserted into the descending duodenum of 5 pigeons and was secured to the body wall and dorsum of each bird. A liquid diet was administered daily (in equal amounts of 0, 4, 8, 12, and 16 hours) for 14 days without adverse effects. On day 15, the catheters were removed, and the birds immediately resumed normal consumption of a pigeon ration and water diet. Although 4 of the 5 birds had minor weight loss, dietary alterations probably could be used on an individual basis to alleviate this problem. After oral alimentation was resumed, the 5 birds exceeded their initial body weight within 7 days. Four weeks after catheter removal, positive-contrast radiographic evaluations indicated that the duodenum of each pigeon appeared normal. Needle catheter duodenostomy was a viable method of alimentation in the domestic pigeon. This technique should be applicable for other avian species requiring bypass of the upper gastrointestinal tract proximal to the region of catheter insertion in the duodenum.

  7. A novel suture method to place and adjust peripheral nerve catheters

    DEFF Research Database (Denmark)

    Rothe, C.; Steen-Hansen, C.; Madsen, M. H.

    2015-01-01

    We have developed a peripheral nerve catheter, attached to a needle, which works like an adjustable suture. We used in-plane ultrasound guidance to place 45 catheters close to the femoral, saphenous, sciatic and distal tibial nerves in cadaver legs. We displaced catheters after their initial...

  8. Infusion's greenfield subsidiary in Poland

    NARCIS (Netherlands)

    Williams, C.; van Eerde, W.; The, D.

    2012-01-01

    The president of Infusion Development Corporation was reviewing the progress of the new subsidiary the company had set up 15 months earlier in Krakow, Poland. The purpose of the subsidiary was to work with other Infusion offices around the world to provide innovative software development services to

  9. Using an indwelling catheter for the domiciliary management of malignant effusions

    Directory of Open Access Journals (Sweden)

    Ramkumar P

    2003-01-01

    Full Text Available Background: Many patients with malignant pleural effusions and ascites require repeated hospital visits for paracentesis. Materials and Methods: Patients and caregivers were taught to drain malignant effusions at home, using an indwelling catheter inserted into the pleural/ peritoneal cavity. The catheter, (ARROW 14 wire gauge with three additional side holes made to prevent blockage was inserted using the Seldenger technique for central venous cannulation and secured with a stitch. A three way stopcock was used to regulate fluid drainage. The caregiver was taught to do biweekly dressings with antiseptic ointment. Results: The catheter has been used in 200 patients over a period of five years. Two patients developed infections in the pleural cavity, which were managed with antibiotics. Two patients needed catheter change because of blockage. Other patients retained the catheter till last follow up or death. The procedure can be carried out as a day case. This article describes practical guidelines for inserting and maintaining the catheter.

  10. Correction of malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance

    International Nuclear Information System (INIS)

    Lee, Seung Ryong; Baek, Kyong Hee; Jung, Gyoo Sik; Huh, Jin Do; Joh, Young Duk; Rim, Hark

    1997-01-01

    To determine the efficacy of correction of a malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance. Between November 1994 and March 1997, we performed 15 manipulations in 12 patients in whom a dual-cuff, straight Tenckhoff peritoneal dialysis catheter had been implanted due to chronic renal failure. The causes of catheter malfunctioning were inadequate drainage of the dialysate(n=14) and painful dialysis(n=1). Under fluoroscopic guidance, adhesiolysis and repositioning of the malfunctioning catheter were performed with an Amplatz Super Stiff guidewire and the stiffener from a biliary drainage catheter. The results of procedures were categorized as either immediate or durable success, this latter being defined as adequate catheter function for at least one month after the procedure. Immediate success was achieved in 14 of 15 procedures (93%), and durable success in 7 of 15(47%). The mean duration of catheter function was 157 (range, 30 to 578) days. After manipulation, abdominal pain developed in eight patients and peritonitis in two, but with conservative treatment, these symptoms improved. The correction of a malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance is an effective means of restoring catheter function and may be an effective alternative to surgical reimplantation of the catheter, or hemodialysis

  11. Correction of malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Ryong; Baek, Kyong Hee; Jung, Gyoo Sik; Huh, Jin Do; Joh, Young Duk; Rim, Hark [Kosin Medical College, Pusan (Korea, Republic of)

    1997-11-01

    To determine the efficacy of correction of a malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance. Between November 1994 and March 1997, we performed 15 manipulations in 12 patients in whom a dual-cuff, straight Tenckhoff peritoneal dialysis catheter had been implanted due to chronic renal failure. The causes of catheter malfunctioning were inadequate drainage of the dialysate(n=14) and painful dialysis(n=1). Under fluoroscopic guidance, adhesiolysis and repositioning of the malfunctioning catheter were performed with an Amplatz Super Stiff guidewire and the stiffener from a biliary drainage catheter. The results of procedures were categorized as either immediate or durable success, this latter being defined as adequate catheter function for at least one month after the procedure. Immediate success was achieved in 14 of 15 procedures (93%), and durable success in 7 of 15(47%). The mean duration of catheter function was 157 (range, 30 to 578) days. After manipulation, abdominal pain developed in eight patients and peritonitis in two, but with conservative treatment, these symptoms improved. The correction of a malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance is an effective means of restoring catheter function and may be an effective alternative to surgical reimplantation of the catheter, or hemodialysis.

  12. Comparison of PIXE and XRF analysis of airborne particulate matter samples collected on Teflon and quartz fibre filters

    Science.gov (United States)

    Chiari, M.; Yubero, E.; Calzolai, G.; Lucarelli, F.; Crespo, J.; Galindo, N.; Nicolás, J. F.; Giannoni, M.; Nava, S.

    2018-02-01

    Within the framework of research projects focusing on the sampling and analysis of airborne particulate matter, Particle Induced X-ray Emission (PIXE) and Energy Dispersive X-ray Fluorescence (ED-XRF) techniques are routinely used in many laboratories throughout the world to determine the elemental concentration of the particulate matter samples. In this work an inter-laboratory comparison of the results obtained from analysing several samples (collected on both Teflon and quartz fibre filters) using both techniques is presented. The samples were analysed by PIXE (in Florence, at the 3 MV Tandetron accelerator of INFN-LABEC laboratory) and by XRF (in Elche, using the ARL Quant'X EDXRF spectrometer with specific conditions optimized for specific groups of elements). The results from the two sets of measurements are in good agreement for all the analysed samples, thus validating the use of the ARL Quant'X EDXRF spectrometer and the selected measurement protocol for the analysis of aerosol samples. Moreover, thanks to the comparison of PIXE and XRF results on Teflon and quartz fibre filters, possible self-absorption effects due to the penetration of the aerosol particles inside the quartz fibre-filters were quantified.

  13. The left atrial catheter: its uses and complications.

    Science.gov (United States)

    Leitman, B S; Naidich, D P; McGuinness, G; McCauley, D I

    1992-11-01

    The authors describe the radiographic appearance of the left atrial catheter, a widely used postsurgical intracardiac device. Recognition of the characteristic appearance of this catheter should be of value in detection of potential complications, including line fracture with resultant retention and/or embolization, infection, prosthetic valve dysfunction, and even cardiac tamponade.

  14. A prototype catheter designed for ultraviolet C disinfection

    DEFF Research Database (Denmark)

    Bak, Jimmy; Begovic, Tanja

    2013-01-01

    UVC light exposure, sampling and plate counting. Findings Two minutes of UVC exposure was sufficient to obtain 4 log10 disinfection for the full-length prototype catheter. This exposure corresponds to ∼40 mJ/cm2 at the catheter tip and indicates that even shorter exposure times can be achieved...

  15. Early catheter removal after radical retropubic prostatectomy: long-term followup.

    Science.gov (United States)

    Koch, Michael O; Nayee, Anish H; Sloan, James; Gardner, Thomas; Wahle, Greg R; Bihrle, Richard; Foster, Richard S

    2003-06-01

    We examine the complication and continence rates with early catheter removal (day 3 or 4) after radical retropubic prostatectomy. A total of 365 patients with localized prostate cancer underwent radical retropubic prostatectomy at Indiana University Hospital with planned urethral catheter removal before discharge home. Low pressure cystograms were performed on postoperative day 3 or 4 to determine if catheter removal was possible. A subset of patients were analyzed using a validated prostate cancer specific questionnaire (University of California, Los Angeles Prostate Cancer Symptom Index) to determine quality of life outcomes. The catheter was removed on postoperative day 3 or 4 in 263 patients (72%). The reasons for leaving the catheter indwelling were significant leak on cystogram or excessive suprapubic drainage (21%), extensive bladder neck reconstruction (1%) and prolonged hospitalization because of an ileus or other complicating factor (6%). Thirteen patients (3.6%) were either unable to void after catheter removal or presented with retention (not associated with hematuria or clots) after hospital discharge, requiring reinsertion of the Foley catheter. A total of 41 patients (11%) had either an early or late complication (excluding incontinence). There were 3 complications (0.8%) that were considered major because they were potentially life threatening or required a return to the operating room. A pelvic abscess developed in 2 patients and a lymphocele in 1, which required percutaneous drainage. After at least 6 months (mean 20.9 months) 140 patients (89.2%) and 14 (8.9%) reported excellent and good continence, respectively. The patient questionnaire demonstrated bother scores to be minimal to no bother for 95% to 98% of patients at 6 and 12 months. This study confirms that it is safe to remove catheters in most patients 3 to 4 days after prostatectomy if a cystogram demonstrates no extravasation. Complication rates and continence rates with this approach

  16. Development of A MEMS Based Manometric Catheter for Diagnosis of Functional Swallowing Disorders

    International Nuclear Information System (INIS)

    Hsu, H Y; Hariz, A J; Omari, T; Teng, M F; Sii, D; Chan, S; Lau, L; Tan, S; Lin, G; Haskard, M; Mulcahy, D; Bakewell, M

    2006-01-01

    Silicon pressure sensors based on micro-electro-mechanical-systems (MEMS) technologies are gaining popularity for applications in bio-medical devices. In this study, a silicon piezo-resistive pressure sensor die is used in a feasibility study of developing a manometric catheter for functional swallowing disorders diagnosis. The function of a manometric catheter is to measure the peak and intrabolus pressures along the esophageal segment during the swallowing action. Previous manometric catheters used the water perfusion technique to measure the pressure changes. This type of catheter is reusable, large in size and the pressure reading is recorded by an external transducer. Current manometric catheters use a solid state pressure sensor on the catheter itself to measure the pressure changes. This type of catheter reduces the discomfort to the patient but it is reusable and is very expensive. We carried out several studies and experiments on the MEMS-based pressure sensor die, and the results show the MEMS-based pressure sensors have a good stability and a good linearity output response, together with the advantage of low excitation biasing voltage and extremely small size. The MEMS-based sensor is the best device to use in the new generation of manometric catheters. The concept of the new MEMS-based manometric catheter consists of a pressure sensing sensor, supporting ring, the catheter tube and a data connector. Laboratory testing shows that the new calibrated catheter is capable of measuring pressure in the range from 0 to 100mmHg and maintaining stable condition on the zero baseline setting when no pressure is applied. In-vivo tests are carried out to compare the new MEMS based catheter with the current version of catheters used in the hospital

  17. Intravenous lipid infusion affects dry matter intake, methane yield, and rumen bacteria structure in late-lactating Holstein cows.

    Science.gov (United States)

    Lamp, Ole; Reyer, Henry; Otten, Winfried; Nürnberg, Gerd; Derno, Michael; Wimmers, Klaus; Metges, Cornelia C; Kuhla, Björn

    2018-03-28

    Increasing the dietary fat content of ruminant diets decreases methane (CH 4 ) production. This effect is caused by the toxic properties of fatty acids on rumen microbial populations, coating of feed particles diminishing the accessibility for microbes, and a reduction in dry matter intake (DMI). The latter effect is caused by postabsorptive long-chain fatty acids eliciting anorexic signaling; however, whether circulating long-chain fatty acids affect rumen CH 4 production alike is unknown. To approach this question, 5 rumen-cannulated Holstein cows in late lactation received 2 jugular catheters and were kept in respiration chambers to measure CH 4 production and DMI for 48 h. In a crossover design, cows were intravenously infused with a 20% lipid emulsion (LIPO) or 0.9% NaCl (CON). The LIPO cows received 2.1 kg of triglycerides/d [0.152 ± 0.007 g of triglycerides/(kg of BW × h) -1 ] consisting of 12.1% palmitic acid, 4.2% stearic acid, 31.1% oleic acid, and 52.7% linoleic acid. Blood and rumen fluid samples were taken hourly during the day. Results showed that LIPO compared with CON infusion increased plasma triglyceride as well as free fatty acid and serotonin concentrations but reduced the proportion of de novo synthesized milk fatty acids (sum of C6 to C16). Daily CH 4 production and DMI were lower, whereas daily CH 4 yield (CH 4 /DMI) was greater in LIPO than CON cows, although CH 4 yield decreased from d 1 to d 2 by 2 to 14% in LIPO-infused cows only. This effect was associated with a higher (acetate + butyrate)/propionate ratio, tending lower propionate concentrations between 24 and 34 h of infusion, reduced relative abundances of genera belonging to Succinivibrio, Ruminococcaceae, and Ruminiclostridium, and greater relative Bacteroidetes genus abundances in the rumen. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  18. ATR FT-IR spectroscopy on Vmh2 hydrophobin self-assembled layers for Teflon membrane bio-functionalization

    International Nuclear Information System (INIS)

    Portaccio, M.; Gravagnuolo, A.M.; Longobardi, S.; Giardina, P.; Rea, I.; De Stefano, L.; Cammarota, M.; Lepore, M.

    2015-01-01

    Graphical abstract: - Highlights: • Hydrophobin self-assembled layers on Teflon in different preparation conditions were investigated. • ATR collection data geometry allowed samples examination without any particular preparation. • Amide content, lipid/amide and carbohydrate/amide ratios of the protein layer were estimated. • Secondary structure of protein was determined for the examined samples. • FT-IR demonstrated to be of extreme relevance in monitoring hydrophobin self-assembled layers preparation. - Abstract: Surface functionalization by layers of hydrophobins, amphiphilic proteins produced by fungi offers a promising and green strategy for fabrication of biomedical and bioanalytical devices. The layering process of the Vmh2 hydrophobin from Pleurotus ostreatus on Teflon membrane has been investigated by Attenuated Total Reflection Fourier Transform Infrared (ATR FT-IR) spectroscopy. In particular, protein layers obtained with hydrophobin purified with two different procedures and in various coating conditions have been examined. The layers have been characterized by quantifying the amide I and amide II band area together with the lipid/amide ratio and carbohydrate/amide ratio. This characterization can be very useful in evaluating the best purification strategy and coating conditions. Moreover the analysis of the secondary structure of the layered protein using the deconvolution procedure of amide I band indicate the prevalent contribution from β-sheet state. The results inferred by infrared spectroscopy have been also confirmed by scanning electron microscopy imaging

  19. ATR FT-IR spectroscopy on Vmh2 hydrophobin self-assembled layers for Teflon membrane bio-functionalization

    Energy Technology Data Exchange (ETDEWEB)

    Portaccio, M., E-mail: marianna.portaccio@unina2.it [Dipartimento di Medicina Sperimentale – Seconda Università di Napoli, Via S.M. di Costantinopoli, 16-80134 Napoli (Italy); Gravagnuolo, A.M., E-mail: alfredomaria.gravagnuolo@unina.it [Dipartimento di Scienze Chimiche, Università “Federico II”, Via Cintia, 21- 80126 Napoli (Italy); Longobardi, S., E-mail: sara.longobardi@unina.it [Dipartimento di Scienze Chimiche, Università “Federico II”, Via Cintia, 21- 80126 Napoli (Italy); Giardina, P., E-mail: paola.giardina@unina.it [Dipartimento di Scienze Chimiche, Università “Federico II”, Via Cintia, 21- 80126 Napoli (Italy); Rea, I., E-mail: ilaria.rea@na.imm.cnr.it [Institute for Microelectronics and Microsystems, CNR, Via P. Castellino, 111-80131 Napoli (Italy); De Stefano, L., E-mail: luca.destefano@na.imm.cnr.it [Institute for Microelectronics and Microsystems, CNR, Via P. Castellino, 111-80131 Napoli (Italy); Cammarota, M., E-mail: marcella.cammarota@unina2.it [Dipartimento di Medicina Sperimentale – Seconda Università di Napoli, Via S.M. di Costantinopoli, 16-80134 Napoli (Italy); Lepore, M., E-mail: maria.lepore@unina2.it [Dipartimento di Medicina Sperimentale – Seconda Università di Napoli, Via S.M. di Costantinopoli, 16-80134 Napoli (Italy)

    2015-10-01

    Graphical abstract: - Highlights: • Hydrophobin self-assembled layers on Teflon in different preparation conditions were investigated. • ATR collection data geometry allowed samples examination without any particular preparation. • Amide content, lipid/amide and carbohydrate/amide ratios of the protein layer were estimated. • Secondary structure of protein was determined for the examined samples. • FT-IR demonstrated to be of extreme relevance in monitoring hydrophobin self-assembled layers preparation. - Abstract: Surface functionalization by layers of hydrophobins, amphiphilic proteins produced by fungi offers a promising and green strategy for fabrication of biomedical and bioanalytical devices. The layering process of the Vmh2 hydrophobin from Pleurotus ostreatus on Teflon membrane has been investigated by Attenuated Total Reflection Fourier Transform Infrared (ATR FT-IR) spectroscopy. In particular, protein layers obtained with hydrophobin purified with two different procedures and in various coating conditions have been examined. The layers have been characterized by quantifying the amide I and amide II band area together with the lipid/amide ratio and carbohydrate/amide ratio. This characterization can be very useful in evaluating the best purification strategy and coating conditions. Moreover the analysis of the secondary structure of the layered protein using the deconvolution procedure of amide I band indicate the prevalent contribution from β-sheet state. The results inferred by infrared spectroscopy have been also confirmed by scanning electron microscopy imaging.

  20. Culture-dependent and -independent investigations of microbial diversity on urinary catheters

    DEFF Research Database (Denmark)

    Xu, Yijuan; Moser, Claus Ernst; Abu Al-Soud, Waleed

    2012-01-01

    Catheter-associated urinary tract infection is caused by bacteria, which ascend the catheter along its external or internal surface to the bladder and subsequently develop into biofilms on the catheter and uroepithelium. Antibiotic-treated bacteria and bacteria residing in biofilm can be difficult...... to culture. In this study we used culture-based and 16S rRNA gene-based culture-independent methods (fingerprinting, cloning, and pyrosequencing) to determine the microbial diversity of biofilms on 24 urinary catheters. Most of the patients were catheterized for...

  1. Urinary catheterization diary – A useful tool in tracking causes of non-deflating Foley catheter

    Directory of Open Access Journals (Sweden)

    C.O. Okorie

    2015-06-01

    Conclusions: Most urinary catheters marketed in developing countries are unidentifiable after unpacking. A catheterization diary is a useful tool for solving catheter-related problems, and its application in health-care facilities should be encouraged. Companies marketing Foley catheters should print the catheter name on both the catheter packaging and on the catheter itself.

  2. Microbiocidal effects of various taurolidine containing catheter lock solutions

    NARCIS (Netherlands)

    Olthof, E.D.; Nijland, R van; Gulich, A.F.; Wanten, G.J.A.

    2015-01-01

    BACKGROUND & AIMS: We have recently shown that a catheter lock solution containing taurolidine dramatically decreases catheter-related bloodstream infections (CRBSI) in patients on home parenteral nutrition (HPN) when compared to heparin. Since several taurolidine formulations are commercially

  3. Effect of abomasal infusion of oligofructose on portal-drained visceral ammonia and urea-nitrogen fluxes in lactating Holstein cows.

    Science.gov (United States)

    Røjen, B A; Larsen, M; Kristensen, N B

    2012-12-01

    The effects of abomasal infusion of oligofructose in lactating dairy cows on the relationship between hindgut fermentation and N metabolism, and its effects on NH(3) absorption and transfer of blood urea-N across the portal-drained viscera versus ruminal epithelia were investigated. Nine lactating Holstein cows fitted with ruminal cannulas and permanent indwelling catheters in major splanchnic blood vessels were used in an unbalanced crossover design with 14-d periods. Treatments were continuous abomasal infusion of water or 1,500 g/d of oligofructose. The same basal diet was fed with both treatments. Eight sample sets of arterial, portal, hepatic, and ruminal vein blood, ruminal fluid, and urine were obtained at 0.5h before the morning feeding and at 0.5, 1.5, 2.5, 3.5, 4.5, 5.5, and 6.5 h after feeding. It was hypothesized that an increased supply of fermentable substrate to the hindgut would increase the uptake of urea-N from blood to the hindgut at the expense of urea-N uptake to the forestomach. The study showed that abomasal oligofructose infusion decreased the total amount of urea-N transferred from the blood to the gut, NH(3) absorption, and arterial blood urea-N concentration. Subsequently, hepatic NH(3) uptake and urea-N production also decreased with oligofructose infusion. Additionally, urea-N concentration in milk and urinary N excretion decreased with oligofructose treatment. The oligofructose infusion did not affect ruminal NH(3) concentrations or any other ruminal variables, nor did it affect ruminal venous - arterial concentration differences for urea-N and NH(3). The oligofructose treatment did not affect milk yield, but did decrease apparent digestibility of OM, N, and starch. Nitrogen excreted in the feces was greater with the oligofructose infusion. In conclusion, the present data suggest that increased hindgut fermentation did not upregulate urea-N transfer to the hindgut at the expense of urea-N uptake by the rumen, and the observed reduction

  4. Empyema and Effusion: Outcome of Image-Guided Small-Bore Catheter Drainage

    International Nuclear Information System (INIS)

    Keeling, A. N.; Leong, S.; Logan, P. M.; Lee, M. J.

    2008-01-01

    Empyema and complicated pleural effusion represent common medical problems. Current treatment options are multiple. The purpose of this study was to access the outcome of image-guided, small-bore catheter drainage of empyema and effusion. We evaluated 93 small-bore catheters in 82 patients with pleural effusion (n = 30) or empyema (n = 52), over a 2-year period. Image guidance was with ultrasound (US; n = 56) and CT (n = 37). All patients were followed clinically, with catheter dwell times, catheter outcome, pleural fluid outcome, reinsertion rates, and need for urokinase or surgery recorded. Ninety-three small-bore chest drains (mean=10.2 Fr; range, 8.2-12.2 Fr) were inserted, with an average dwell time of 7.81 days for empyemas and 7.14 days for effusions (p > 0.05). Elective removal rates (73% empyema vs 86% effusions) and dislodgement rates (12% empyema vs 13% effusions) were similar for both groups. Eight percent of catheters became blocked and 17% necessitated reinsertion in empyemas, with no catheters blocked or requiring reinsertion in effusions (p < 0.05). Thirty-two patients (51%) required urokinase in the empyema group, versus 2 patients (6%) in the effusion group (p < 0.05). All treatment failures, requiring surgery, occurred in the empyema group (19%; n = 12; p < 0.05). In conclusion, noninfected pleural collections are adequately treated with small-bore catheters, however, empyemas have a failure rate of 19%. The threshold for using urokinase and larger-bore catheters should be low in empyema

  5. Hematologic patients' clinical and psychosocial experiences with implanted long-term central venous catheter

    DEFF Research Database (Denmark)

    Møller, Tom; Adamsen, Lis

    2010-01-01

    A significant decrease in catheter-related infections was demonstrated in our earlier randomized controlled trial of central venous catheter (CVC) care in hematologic patients.......A significant decrease in catheter-related infections was demonstrated in our earlier randomized controlled trial of central venous catheter (CVC) care in hematologic patients....

  6. Pharmacokinetics and toxicology of continuously infused nitroimidazoles

    International Nuclear Information System (INIS)

    Eifel, P.J.; Brown, J.M.

    1984-01-01

    The pharmacokinetics and toxicology of misonidazole (MISO) and SR-2508 given by continuous intraperitoneal infusion were studied in female C 3 H mice. The survival (time to death) of animals receiving continuous infusions of SR-2508 and MISO was compared and related to plasma concentration, rate of infusion and total amount of drug delivered. Brain and plasma concentrations were determined by HPLC. For SR-2508, plasma concentration was directly proportional to the infusion rate. However, as the infusion rate of MISO was doubled, the plasma concentration of MISO increased approximately 6-fold, reflecting a substantial increase in the apparent half-life. The brain/plasma concentration ratio in animals infused for up to 6 days with SR-2508 remained constant, at approximately 0.09. At plasma concentrations of 0.08-1.5 mM, animals receiving SR-2508 survived approximately 3 times as long as animals exposed to a comparable plasma concentration of MISO. Even at the lowest infusion rates employed in this study, the survival of mice receiving SR-2508 was much shorter than would have been predicted if the toxicity of these two drugs were solely related to the integral brain exposure. The low brain/plasma concentration ratio of SR-2508 was maintained throughout long continuous exposures

  7. MONITORING TETESAN INFUS BERBASIS MIKROKONTROLER ATMEGA16

    Directory of Open Access Journals (Sweden)

    Ardiyanto Iqbal Nugroho

    2015-09-01

    Penelitian ini menghasilkan suatu alat monitoring tetesan infus yang dapat memberikan informasi mengenai laju kecepatan tetesan dan kondisi cairan pada infus. Sistem yang secara realtime dimonitoring oleh perawat ini dapat mengurangi permasalahan yang timbul karena kelalaian petugas. Sehingga perawat tidak secara manual dalam mengatur kecepatan tetesan infus dan meningkatkan pelayanan kepada pasien.

  8. Determination of 24-hour insulin infusion pattern by an artificial endocrine pancreas for intravenous insulin infusion with a miniature pump

    DEFF Research Database (Denmark)

    Kølendorf, K; Christiansen, J S; Bojsen, J

    1981-01-01

    UNLABELLED: Intravenous insulin infusion with a glucose controlled insulin infusion system (GCIIS) is known to restore glucose homeostasis. A simpler approach to improve blood glucose regulation is preprogrammed intravenous insulin infusion with portable pumps without sensor-mediated feedback. We...... report a study designed to evaluate whether the preprogrammed insulin infusion pattern to be used in the miniature insulin infusion pump (MIIP) could be optimized by concomitant employment of the GCIIS for blood glucose control. Six juvenile-onset insulin-dependent diabetics (mean age 31 yrs) were...... studied. Mean blood glucose (MBG) was 6.2 mmol/l +/- 0.5 (SD) during glucose controlled infusion and 5.3 +/- 0.6 during the combined MIIP + GCIIS-day. The insulin requirements calculated from the s.c. regimen (56 U +/- 10 SD) were identical to the GCIIS-measured (51 U +/- 14) and to the amounts delivered...

  9. Covalent immobilisation of antibodies in Teflon-FEP microfluidic devices for the sensitive quantification of clinically relevant protein biomarkers.

    Science.gov (United States)

    Pivetal, Jeremy; Pereira, Filipa M; Barbosa, Ana I; Castanheira, Ana P; Reis, Nuno M; Edwards, Alexander D

    2017-03-13

    This study reports for the first time the sensitive colorimetric and fluorescence detection of clinically relevant protein biomarkers by sandwich immunoassays using the covalent immobilisation of antibodies onto the fluoropolymer surface inside Teflon®-FEP microfluidic devices. Teflon®-FEP has outstanding optical transparency ideal for high-sensitivity colorimetric and fluorescence bioassays, however this thermoplastic is regarded as chemically inert and very hydrophobic. Covalent immobilisation can offer benefits over passive adsorption to plastic surfaces by allowing better control over antibody density, orientation and analyte binding capacity, and so we tested a range of different and novel covalent immobilisation strategies. We first functionalised the inner surface of a 10-bore, 200 μm internal diameter FEP microcapillary film with high-molecular weight polyvinyl alcohol (PVOH) without changing the outstanding optical transparency of the device delivered by the matched refractive index of FEP and water. Glutaraldehyde immobilisation was compared with the use of photoactivated linkers and NHS-ester crosslinkers for covalently immobilising capture antibodies onto PVOH. Three clinically relevant sandwich ELISAs were tested against the cytokine IL-1β, the myocardial infarct marker cardiac troponin I (cTnI), and the chronic heart failure marker brain natriuretic peptide (BNP). Overall, glutaraldehyde immobilisation was effective for BNP assays, but yielded unacceptable background for IL-1β and cTnI assays caused by direct binding of the biotinylated detection antibody to the modified PVOH surface. We found NHS-ester groups reacted with APTES-treated PVOH coated fluoropolymers. This facilitated a novel method for capture antibody immobilisation onto fluoropolymer devices using a bifunctional NHS-maleimide crosslinker. The density of covalently immobilised capture antibodies achieved using PVOH/APTES/NHS/maleimide approached levels seen with passive adsorption

  10. Efeitos da infusão contínua de propofol ou etomidato sobre variáveis intracranianas em cães Effects of propofol or etomidate intravenous infusion on intracranial variables in dogs

    Directory of Open Access Journals (Sweden)

    D.P. Paula

    2010-04-01

    .2mg/kg/min. The initial measurement (M1 was recorded 30 minutes after the implant of the fiber optic catheter and, after that, every 20 minutes (M2, M3, and M4. The studied parameters were intracranial pressure (ICP, cerebral perfusion pressure (CPP, intracranial temperature (ICT, body temperature (BT, mean arterial pressure (MAP, and heart rate (HR. The propofol and etomidate did not change the studied variables, except the ICT and BT. It was concluded that the continuous infusion of these drugs maintains the cerebral perfusion and autoregulation. Dogs anesthetized with etomidate have adverse effects and body and intracranial temperature decrease.

  11. Minimizing Hemodialysis Catheter Dysfunction: An Ounce of Prevention

    Directory of Open Access Journals (Sweden)

    Timmy Lee

    2012-01-01

    Full Text Available The maintenance of tunneled catheter (TC patency is critical for the provision of adequate hemodialysis in patients who are TC-dependent. TC dysfunction results in the need for costly and inconvenient interventions, and reduced quality of life. Since the introduction of TCs in the late 1980s, heparin catheter lock has been the standard prophylactic regimen for the prevention of TC dysfunction. More recently, alternative catheter locking agents have emerged, and in some cases have shown to be superior to heparin lock with respect to improving TC patency and reducing TC-associated infections. These include citrate, tissue plasminogen activator, and a novel agent containing sodium citrate, methylene blue, methylparaben, and propylparaben. In addition, prophylaxis using oral anticoagulants/antiplatelet agents, including warfarin, aspirin, ticlodipine, as well as the use of modified heparin-coated catheters have also been studied for the prevention of TC dysfunction with variable results. The use of oral anticoagulants and/or antiplatelet agents as primary or secondary prevention of TC dysfunction must be weighed against their potential adverse effects, and should be individualized for each patient.

  12. Clinical study of the Erlanger silver catheter--data management and biometry.

    Science.gov (United States)

    Martus, P; Geis, C; Lugauer, S; Böswald, M; Guggenbichler, J P

    1999-01-01

    The clinical evaluation of venous catheters for catheter-induced infections must conform to a strict biometric methodology. The statistical planning of the study (target population, design, degree of blinding), data management (database design, definition of variables, coding), quality assurance (data inspection at several levels) and the biometric evaluation of the Erlanger silver catheter project are described. The three-step data flow included: 1) primary data from the hospital, 2) relational database, 3) files accessible for statistical evaluation. Two different statistical models were compared: analyzing the first catheter only of a patient in the analysis (independent data) and analyzing several catheters from the same patient (dependent data) by means of the generalized estimating equations (GEE) method. The main result of the study was based on the comparison of both statistical models.

  13. Predicting success of catheter drainage in infected necrotizing pancreatitis

    NARCIS (Netherlands)

    Hollemans, Robbert A.; Bollen, Thomas L.; Van Brunschot, Sandra; Bakker, Olaf J.; Ali, Usama Ahmed; Van Goor, Harry; Boermeester, Marja A.; Gooszen, Hein G.; Besselink, Marc G.; Van Santvoort, Hjalmar C.

    2016-01-01

    Introduction: At least 30% of patients with infected necrotizing pancreatitis are successfully treated with catheter drainage alone. It is currently not possible to predict which patients also need necrosectomy. We evaluated predictive factors for successful catheter drainage. Methods: This was a

  14. Predicting Success of Catheter Drainage in Infected Necrotizing Pancreatitis

    NARCIS (Netherlands)

    Hollemans, R.A.; Bollen, T.L.; Brunschot, S. van; Bakker, O.J.; Ali, U. Ahmed; Goor, H. van; Boermeester, M.A.; Gooszen, H.G.; Besselink, M.G.; Santvoort, H.C. van

    2016-01-01

    INTRODUCTION: At least 30% of patients with infected necrotizing pancreatitis are successfully treated with catheter drainage alone. It is currently not possible to predict which patients also need necrosectomy. We evaluated predictive factors for successful catheter drainage. METHODS: This was a

  15. Qureshi-5 Catheter for Complex Supra- and Abdominal-Aortic Catheterization.

    Science.gov (United States)

    Qureshi, Adnan I; Xiao, WeiGang; Liu, HongLiang

    2015-10-01

    The use of previously described catheter technique was expanded to complex supra- and abdominal- aortic catheterizations. A new (Qureshi 5) catheter with curved shape at the distal end that has two lumens was used. One of lumens can accommodate a 0.035-inch guide wire and the second lumen can accommodate a 0.018-inch guide wire and terminates at the beginning of the distal curve of the first lumen. The manipulation and engagement of the curved distal end catheter was facilitated by rotation and movement of the J-shaped 0.018-inch guide wire extended coaxial and beyond the distal end of catheter. Subsequently, either contrast was injected or a 0.035-inch guide wire advanced into the target artery. The catheters were used in one patient to perform diagnostic cerebral and abdominal angiography through a 6F introducer sheath placed in the right common femoral artery. The catheterization was complex because of severe tortuosity of arch and descending aorta secondary to kyphosis. The left and right internal carotid arteries and left and right vertebral arteries, left renal artery, and superior mesenteric artery were catheterized in patient (fluoroscopy time 19:46 min). No complications were observed in the patient. The Qureshi-5 catheter was successful in complex supra- and abdominal-aortic catheterizations.

  16. Infusing PDA technology into nursing education.

    Science.gov (United States)

    White, Ann; Allen, Patricia; Goodwin, Linda; Breckinridge, Daya; Dowell, Jeffery; Garvy, Ryan

    2005-01-01

    Use of the personal digital assistant (PDA) has been infused into the accelerated baccalaureate program at Duke University to help prepare nursing students for professional practice. The authors provide an overview of the use of PDAs in the classroom, laboratory, and clinical setting. Technical aspects of PDA infusion and steps to ensure regulatory compliance are explored. Benefits of PDA use by both faculty and students in the program and challenges met with the infusion of this technology are also described.

  17. The effect of selective intraarterial infusion of the anticancer agents on cerebral hemodynamics: Concerned with the change of CBF in the non-tumoral tissue. Quantitative evaluation using 123-IMP-SPECT

    International Nuclear Information System (INIS)

    Hirano, Hiroko; Tomura, Noriaki; Kobayashi, Mitsuru; Ohyama, Yoichi; Watarai, Jiro

    1996-01-01

    The effect of intraarterial chemotherapy on cerebral blood flow (CBF) of patients with brain tumor was quantitatively studied by means of single photon emission computed tomography (SPECT). The subjects consisted of twenty patients with brain tumor (2 fibrillary astrocytoma grade II, 9 malignant astrocytoma grade III, 7 glioblastoma grade IV, 1 pineoblastoma grade IV and 1 malignant glioma). In twenty patients, twenty-four intraarterial infusions (IAs) were performed. IA chemotherapy was selectively performed through the Tracker-18 catheter, using nimustine (ACNU) in 22 infusions and tumor necrotizing factor-α (TNF) in 2 infusions. CBF was quantitatively measured by Kuhl's method, using N-isopropyl-p= 123 I=-iodoamphetamine (IMP). All patients underwent a baseline SPECT scan 1-10 days prior to IA chemotherapy, and a scan 1-22 days after IA. The change of CBF before and after IA, particularly in the non-tumoral tissue, was highlighted. CBF in the infused region as well as in the non-infused region variously changed after IA. The mean CBF of the whole brain before IA was 47.8±11.9 (mean±SD, n=24) ml/100 ml/min and than after IA was 49.3±12.4. CBF in the infused region changed (-17-+52%) after IA chemotherapy. In 12 patients whose CBF measurement was performed within 5 days after IA, CBF increased in 6 patients compared with that measured before IA. In 3 patients whose CBF measurement was performed more than 10 days after IA, CBF decreased in all of patients. This result suggested that the increase of CBF may possibly be an early change after IA chemotherapy, and that an augmented cellular metabolism and/or acute inflammatory reaction may explain this early change after IA chemotherapy. (author)

  18. Catheter design optimization for practical intravascular photoacoustic imaging (IVPA) of vulnerable plaques

    Science.gov (United States)

    Iskander-Rizk, Sophinese; Wu, Min; Springeling, Geert; Mastik, Frits; Beurskens, Robert H. S. H.; van der Steen, Antonius F. W.; van Soest, Gijs

    2018-02-01

    Intravascular photoacoustic/ultrasound imaging (IVPA/US) can image the structure and composition of atherosclerotic lesions identifying lipid-rich plaques ex vivo and in vivo. In the literature, multiple IVPA/US catheter designs were presented and validated both in ex-vivo models and preclinical in-vivo situations. Since the catheter is a critical component of the imaging system, we discuss here a catheter design oriented to imaging plaque in a realistic and translatable setting. We present a catheter optimized for light delivery, manageable flush parameters and robustness with reduced mechanical damage risks at the laser/catheter joint interface. We also show capability of imaging within sheath and in water medium.

  19. Peripherally inserted central catheters. Guidewire versus nonguidewire use: a comparative study.

    Science.gov (United States)

    Loughran, S C; Edwards, S; McClure, S

    1992-01-01

    To date, no research articles have been published that explore the practice of using guidewires for placement of peripherally inserted central catheters. The literature contains speculations regarding the pros and cons of guidewire use. However, no studies to date have compared patient outcomes when peripherally inserted central catheter lines are inserted with and without guidewires. To examine the use of guidewires for peripherally inserted central lines, a comparative study was conducted at two acute care facilities, one using guidewires for insertion and one inserting peripherally inserted central catheter lines without guidewires. 109 catheters were studied between January 1, 1990 and January 1, 1991. The primary focus of this study was to examine whether guidewire use places patients at higher risk for catheter-related complications, particularly phlebitis. No significant differences in phlebitis rates between the two study sites were found. Other catheter-related and noncatheter-related complications were similar between the two facilities. The results of this study do not support the belief that guidewire use increases complication rates.

  20. Successful Use of Modified Suprapubic Catheter to Rescue Prostatorectal Fistula

    Directory of Open Access Journals (Sweden)

    Yi-Chun Chiu

    2008-06-01

    Full Text Available Prostatorectal fistula is a complication following radiotherapy. It remains a clinical challenge to treat because most patients experience a poor quality of life. This case report discusses a modified suprapubic catheter for use in a patient with a prostatorectal fistula that developed after radiotherapy for localized prostate cancer. It is an inexpensive, easily available, and more patient-tolerable catheter that improves quality of life. Herein, we describe the development of this catheter.