Sample records for technology verification tests

  1. Battery Technology Life Verification Test Manual Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Jon P. Christophersen

    2012-12-01

    The purpose of this Technology Life Verification Test (TLVT) Manual is to help guide developers in their effort to successfully commercialize advanced energy storage devices such as battery and ultracapacitor technologies. The experimental design and data analysis discussed herein are focused on automotive applications based on the United States Advanced Battery Consortium (USABC) electric vehicle, hybrid electric vehicle, and plug-in hybrid electric vehicle (EV, HEV, and PHEV, respectively) performance targets. However, the methodology can be equally applied to other applications as well. This manual supersedes the February 2005 version of the TLVT Manual (Reference 1). It includes criteria for statistically-based life test matrix designs as well as requirements for test data analysis and reporting. Calendar life modeling and estimation techniques, including a user’s guide to the corresponding software tool is now provided in the Battery Life Estimator (BLE) Manual (Reference 2).

  2. Test/QA Plan for Verification of Leak Detection and Repair Technologies

    Science.gov (United States)

    The purpose of the leak detection and repair (LDAR) test and quality assurance plan is to specify procedures for a verification test applicable to commercial LDAR technologies. The purpose of the verification test is to evaluate the performance of participating technologies in b...

  3. ENVIRONMENTAL TECHNOLOGY VERIFICATION: TEST/QA PLAN FOR THE VERIFICATION TESTING OF SELECTIVE CATALYTIC REDUCTION CONTROL TECHNOLOGIES FOR HIGHWAY, NONROAD, AND STATIONARY USE DIESEL ENGINES

    Science.gov (United States)

    The U.S. Environmental Protection Agency established the Environmental Technology Verification Program to accelerate the development and commercialization of improved environmental technology through third party verification and reporting of product performance. Research Triangl...

  4. TEST DESIGN FOR ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) OF ADD-ON NOX CONTROL UTILIZING OZONE INJECTION

    Science.gov (United States)

    The paper discusses the test design for environmental technology verification (ETV) of add-0n nitrogen oxides (NOx) control utilizing ozone injection. (NOTE: ETV is an EPA-established program to enhance domestic and international market acceptance of new or improved commercially...

  5. Environmental Technology Verification: Supplement to Test/QA Plan for Biological and Aerosol Testing of General Ventilation Air Cleaners; Bioaerosol Inactivation Efficiency by HVAC In-Duct Ultraviolet Light Air Cleaners

    Science.gov (United States)

    The Air Pollution Control Technology Verification Center has selected general ventilation air cleaners as a technology area. The Generic Verification Protocol for Biological and Aerosol Testing of General Ventilation Air Cleaners is on the Environmental Technology Verification we...

  6. Environmental technology verification methods

    CSIR Research Space (South Africa)

    Szewczuk, S

    2016-03-01

    Full Text Available Environmental Technology Verification (ETV) is a tool that has been developed in the United States of America, Europe and many other countries around the world to help innovative environmental technologies reach the market. Claims about...

  7. ENVIRONMENTAL TECHNOLOGY VERIFICATION COATINGS AND COATING EQUIPMENT PROGRAM (ETV CCEP), FINAL TECHNOLOGY APPLICATIONS GROUP TAGNITE--TESTING AND QUALITY ASSURANCE PLAN (T/QAP)

    Science.gov (United States)

    The overall objective of the Environmental Testing and Verification Coatings and Coating Equipment Program is to verify pollution prevention and performance characteristics of coating technologies and make the results of the testing available to prospective coating technology use...

  8. DOE/LLNL verification symposium on technologies for monitoring nuclear tests related to weapons proliferation

    International Nuclear Information System (INIS)

    Nakanishi, K.K.

    1993-01-01

    The rapidly changing world situation has raised concerns regarding the proliferation of nuclear weapons and the ability to monitor a possible clandestine nuclear testing program. To address these issues, Lawrence Livermore National Laboratory's (LLNL) Treaty Verification Program sponsored a symposium funded by the US Department of Energy's (DOE) Office of Arms Control, Division of Systems and Technology. The DOE/LLNL Symposium on Technologies for Monitoring Nuclear Tests Related to Weapons Proliferation was held at the DOE's Nevada Operations Office in Las Vegas, May 6--7,1992. This volume is a collection of several papers presented at the symposium. Several experts in monitoring technology presented invited talks assessing the status of monitoring technology with emphasis on the deficient areas requiring more attention in the future. In addition, several speakers discussed proliferation monitoring technologies being developed by the DOE's weapons laboratories

  9. Software verification and testing

    Science.gov (United States)

    1985-01-01

    General procedures for software verification and validation are provided as a guide for managers, programmers, and analysts involved in software development. The verification and validation procedures described are based primarily on testing techniques. Testing refers to the execution of all or part of a software system for the purpose of detecting errors. Planning, execution, and analysis of tests are outlined in this document. Code reading and static analysis techniques for software verification are also described.

  10. Nuclear test ban verification

    International Nuclear Information System (INIS)

    Chun, Kin-Yip

    1991-07-01

    This report describes verification and its rationale, the basic tasks of seismic verification, the physical basis for earthquake/explosion source discrimination and explosion yield determination, the technical problems pertaining to seismic monitoring of underground nuclear tests, the basic problem-solving strategy deployed by the forensic seismology resarch team at the University of Toronto, and the scientific significance of the team's research. The research carried out at the Univeristy of Toronto has two components: teleseismic verification using P wave recordings from the Yellowknife Seismic Array (YKA), and regional (close-in) verification using high-frequency L g and P n recordings from the Eastern Canada Telemetered Network. Major differences have been found in P was attenuation among the propagation paths connecting the YKA listening post with seven active nuclear explosion testing areas in the world. Significant revisions have been made to previously published P wave attenuation results, leading to more interpretable nuclear explosion source functions. (11 refs., 12 figs.)

  11. Technology Foresight and nuclear test verification: a structured and participatory approach

    Science.gov (United States)

    Noack, Patrick; Gaya-Piqué, Luis; Haralabus, Georgios; Auer, Matthias; Jain, Amit; Grenard, Patrick

    2013-04-01

    As part of its mandate, the CTBTO's nuclear explosion monitoring programme aims to maintain its sustainability, effectiveness and its long-term relevance to the verification regime. As such, the PTS is conducting a Technology Foresight programme of activities to identify technologies, processes, concepts and ideas that may serve said purpose and become applicable within the next 20 years. Through the Technology Foresight activities (online conferences, interviews, surveys, workshops and other) we have involved the wider science community in the fields of seismology, infrasound, hydroacoustics, radionuclide technology, remote sensing and geophysical techniques. We have assembled a catalogue of over 200 items, which incorporate technologies, processes, concepts and ideas which will have direct future relevance to the IMS (International Monitoring System), IDC (International Data Centre) and OSI (On-Site Inspection) activities within the PTS. In order to render this catalogue as applicable and useful as possible for strategy and planning, we have devised a "taxonomy" based on seven categories, against which each technology is assessed through a peer-review mechanism. These categories are: 1. Focus area of the technology in question: identify whether the technology relates to (one or more of the following) improving our understanding of source and source physics; propagation modelling; data acquisition; data transport; data processing; broad modelling concepts; quality assurance and data storage. 2. Current Development Stage of the technology in question. Based on a scale from one to six, this measure is specific to PTS needs and broadly reflects Technology Readiness Levels (TRLs). 3. Impact of the technology on each of the following capabilities: detection, location, characterization, sustainment and confidence building. 4. Development cost: the anticipated monetary cost of validating a prototype (i.e. Development Stage 3) of the technology in question. 5. Time to

  12. CANDU RU fuel manufacturing basic technology development and advanced fuel verification tests

    International Nuclear Information System (INIS)

    Chung, Chang Hwan; Chang, S.K.; Hong, S.D.

    1999-04-01

    A PHWR advanced fuel named the CANFLEX fuel has been developed through a KAERI/AECL joint Program. The KAERI made fuel bundle was tested at the KAERI Hot Test Loop for the performance verification of the bundle design. The major test activities were the fuel bundle cross-flow test, the endurance fretting/vibration test, the freon CHF test, and the fuel bundle heat-up test. KAERI also has developing a more advanced PHWR fuel, the CANFLEX-RU fuel, using recovered uranium to extend fuel burn-up in the CANDU reactors. For the purpose of proving safety of the RU handling techniques and appraising feasibility of the CANFLEX-RU fuel fabrication in near future, a physical, chemical and radiological characterization of the RU powder and pellets was performed. (author). 54 refs., 46 tabs., 62 figs

  13. CANDU RU fuel manufacturing basic technology development and advanced fuel verification tests

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Chang Hwan; Chang, S.K.; Hong, S.D. [and others

    1999-04-01

    A PHWR advanced fuel named the CANFLEX fuel has been developed through a KAERI/AECL joint Program. The KAERI made fuel bundle was tested at the KAERI Hot Test Loop for the performance verification of the bundle design. The major test activities were the fuel bundle cross-flow test, the endurance fretting/vibration test, the freon CHF test, and the fuel bundle heat-up test. KAERI also has developing a more advanced PHWR fuel, the CANFLEX-RU fuel, using recovered uranium to extend fuel burn-up in the CANDU reactors. For the purpose of proving safety of the RU handling techniques and appraising feasibility of the CANFLEX-RU fuel fabrication in near future, a physical, chemical and radiological characterization of the RU powder and pellets was performed. (author). 54 refs., 46 tabs., 62 figs.

  14. Test/QA Plan for Verification of Coliform Detection Technologies for Drinking Water

    Science.gov (United States)

    The coliform detection technologies to be tested use chromatogenic and fluorogenic growth media to detect coliforms and E. coli based on the enzymatic activity of these organisms. The systems consist of single-use sample containers that contain pre-measured reagents and can be u...

  15. Biometric Technologies and Verification Systems

    CERN Document Server

    Vacca, John R

    2007-01-01

    Biometric Technologies and Verification Systems is organized into nine parts composed of 30 chapters, including an extensive glossary of biometric terms and acronyms. It discusses the current state-of-the-art in biometric verification/authentication, identification and system design principles. It also provides a step-by-step discussion of how biometrics works; how biometric data in human beings can be collected and analyzed in a number of ways; how biometrics are currently being used as a method of personal identification in which people are recognized by their own unique corporal or behavior

  16. Verification of wet blasting decontamination technology

    International Nuclear Information System (INIS)

    Matsubara, Sachito; Murayama, Kazunari; Yoshida, Hirohisa; Igei, Shigemitsu; Izumida, Tatsuo

    2013-01-01

    Macoho Co., Ltd. participated in the projects of 'Decontamination Verification Test FY 2011 by the Ministry of the Environment' and 'Decontamination Verification Test FY 2011 by the Cabinet Office.' And we tested verification to use a wet blasting technology for decontamination of rubble and roads contaminated by the accident of Fukushima Daiichi Nuclear Power Plant of the Tokyo Electric Power Company. As a results of the verification test, the wet blasting decontamination technology showed that a decontamination rate became 60-80% for concrete paving, interlocking, dense-grated asphalt pavement when applied to the decontamination of the road. When it was applied to rubble decontamination, a decontamination rate was 50-60% for gravel and approximately 90% for concrete and wood. It was thought that Cs-134 and Cs-137 attached to the fine sludge scraped off from a decontamination object and the sludge was found to be separated from abrasives by wet cyclene classification: the activity concentration of the abrasives is 1/30 or less than the sludge. The result shows that the abrasives can be reused without problems when the wet blasting decontamination technology is used. (author)

  17. ENVIRONMENTAL TECHNOLOGY VERIFICATION--TEST REPORT OF MOBILE SOURCE EMISSION CONTROL DEVICES, FLINT HILLS RESOURCES, LP, CCD15010 DIESEL FUEL FORMULATION WITH HITEC4121 ADDITIVE

    Science.gov (United States)

    The U.S. Environmental Protection Agency (EPA) has created the Environmental Technology Verification (ETV) Program to facilitate the deployment of innovative or improved environmental technologies through performance verification and dissemination of information. ETV seeks to ach...

  18. ENVIRONMENTAL TECHNOLOGY VERIFICATION, TEST REPORT OF MOBILE SOURCE EMISSIONS CONTROL DEVICES/CLEAN DIESEL TECHNOLOGIES FUEL BORNE CATALYST WITH CLEANAIR SYSTEM'S DIESEL OXIDATION CATALYST

    Science.gov (United States)

    The Environmental Technology Verification report discusses the technology and performance of the Fuel-Borne Catalyst with CleanAir System's Diesel Oxidation Catalyst manufactured by Clean Diesel Technologies, Inc. The technology is a fuel-borne catalyst used in ultra low sulfur d...

  19. ENVIRONMENTAL TECHNOLOGY VERIFICATION, TEST REPORT OF MOBILE SOURCE EMISSIONS CONTROL DEVICES: CLEAN DIESEL TECHNOLOGIES FUEL-BORNE CATALYST WITH MITSUI/PUREARTH CATALYZED WIRE MESH FILTER

    Science.gov (United States)

    The Environmental Technology Verification report discusses the technology and performance of the Fuel-Borne Catalyst with Mitsui/PUREarth Catalyzed Wire Mesh Filter manufactured by Clean Diesel Technologies, Inc. The technology is a platinum/cerium fuel-borne catalyst in commerci...

  20. USE OF PERFLUOROCARBON TRACER (PFT) TECHNOLOGY FOR SUBSURFACE BARRIER INTEGRITY VERIFICATION AT THE WALDO TEST SITE.

    Energy Technology Data Exchange (ETDEWEB)

    SULLIVAN,T.

    1999-06-01

    Testing of perfluorocarbon gas tracers (PFT) on a subsurface barrier with known flaws was conducted at the Waldo Test Site operated by Science and Engineering Associates, Inc (SEA). The tests involved the use of five unique PFTs with a different tracer injected along the interior of each wall of the barrier. A fifth tracer was injected exterior to the barrier to examine the validity of diffusion controlled transport of the PFTs. The PFTs were injected for three days at a nominal flow rate of 15 cm{sup 3}/min and concentrations in the range of a few hundred ppm. Approximately 65 liters of air laced with tracer was injected for each tracer. The tracers were able to accurately detect the presence of the engineered flaws. Two flaws were detected on the north and east walls, and one flaw was detected on the south and west walls. In addition, one non-engineered flaw at the seam between the north and east walls was also detected. The use of multiple tracers provided independent confirmation of the flaws and permitted a distinction between tracers arriving at a monitoring port after being released from a nearby flaw and non-engineered flaws. The PFTs detected the smallest flaw, 0.5 inches in diameter. Visual inspection of the data showed excellent agreement with the known flaw locations and the relative size of the flaws was accurately estimated. Simultaneous with the PFT tests, SEA conducted tests with another gas tracer sulfur hexafluoride (SF{sub 6}).

  1. Verification of the machinery condition monitoring technology by fault simulation tests

    International Nuclear Information System (INIS)

    Maehara, Takafumi; Watanabe, Yukio; Osaki, Kenji; Higuma, Koji; Nakano, Tomohito

    2009-01-01

    This paper shows the test items and equipments introduced by Japan Nuclear Energy Safety Organization to establish the monitoring technique for machinery conditions. From the result of vertical pump simulation tests, it was confirmed that fault analysis was impossible by measuring the accelerations on both motor and pump column pipes, however, was possible by measuring of pump shaft vibrations. Because hydraulic whirls by bearing wear had significant influences over bearing misalignments and flow rates, the monitoring trends must be done under the same condition (on bearing alignments and flow rates). We have confirmed that malfunctions of vertical pumps can be diagnosed using measured shaft vibration by ultrasonic sensors from outer surface of pump casing on the floor. (author)

  2. USE OF PERFLUOROCARBON TRACER (PFT) TECHNOLOGY FOR SUBSURFACE BARRIER INTEGRITY VERIFICATION AT THE WALDO TEST SITE

    Energy Technology Data Exchange (ETDEWEB)

    SULLIVAN,T.; HEISER,J.; SENUM,G.; MILLIAN,L.

    2000-02-27

    Researchers from Brookhaven National Laboratory (BNL) tested perfluorocarbon (PFT) gas tracers on a subsurface barrier with known flaws at the Waldo test facility [operated by Science and Engineering Associates, Inc (SEA)]. The tests involved the use of five unique PFT tracers with a different tracer injected along the interior of each wall of the barrier. A fifth tracer was injected exterior to the barrier to examine the validity of diffusion controlled transport of the PFTs. The PFTs were injected for three days at a nominal flow rate of 15 cm{sup 3}/min and a concentrations in the range of a few hundred ppm. Approximately 65 liters of air laced with tracer was injected for each tracer. The tracers were able to accurately detect the presence of the engineered flaws. Two flaws were detected on the north and east walls and lane flaw was detected on the south and west walls. In addition, one non-engineered flaw at the seam between the north and east walls was also detected. The use of multiple tracers provided independent confirmation of the flaws and permitted a distinction between tracers arriving at a monitoring port after being released from a nearby flaw and non-engineered flaws. The PFTs detected the smallest flaw, 0.5 inches in diameter. Visual inspection of the data showed excellent agreement with the known flaw locations and the relative size of the flaws was accurately estimated.

  3. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, PERFORMANCE TEST RESULTS FOR THE A AND A ENVIRONMENTAL SEALS' SEAL ASSIST SYSTEM (SAS), PHASE I--TECHNOLOGY VERIFICATION REPORT

    Science.gov (United States)

    The report presents results of tests determining the efficacy of A&A Environmental Seals, Inc's Seal Assist System (SAS) in preventing natural gas compressor station's compressor rod packing leaks from escaping into the atmosphere. The SAS consists of an Emission Containment Glan...

  4. ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) PROGRAM: FUEL CELLS

    Science.gov (United States)

    The U.S. Environmental Protection Agency (EPA) Environmental Technology Verification (ETV) Program evaluates the performance of innovative air, water, pollution prevention and monitoring technologies that have the potential to improve human health and the environment. This techno...

  5. ENVIRONMENTAL TECHNOLOGY VERIFICATION--TEST REPORT OF MOBILE SOURCE EMISSION CONTROL DEVICES, CUMMINS EMISSION SOLUTIONS AND CUMMINS FILTRATION DIESEL OXIDATION CATALYST AND CLOSED CRANKCASE VENTILATION SYSTEM

    Science.gov (United States)

    The U.S. EPA has created the Environmental Technology Verification (ETV) Program. ETV seeks to provide high-quality, peer-reviewed data on technology performance. The Air Pollution Control Technology (APCT) Verification Center, a center under the ETV Program, is operated by Res...

  6. INNOVATIVE TECHNOLOGY VERIFICATION REPORT XRF ...

    Science.gov (United States)

    The Niton XLt 700 Series (XLt) XRF Services x-ray fluorescence (XRF) analyzer was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation (SITE) Program. The field portion of the demonstration was conducted in January 2005 at the Kennedy Athletic, Recreational and Social Park (KARS) at Kennedy Space Center on Merritt Island, Florida. The demonstration was designed to collect reliable performance and cost data for the XLt analyzer and seven other commercially available XRF instruments for measuring trace elements in soil and sediment. The performance and cost data were evaluated to document the relative performance of each XRF instrument. This innovative technology verification report describes the objectives and the results of that evaluation and serves to verify the performance and cost of the XLt analyzer. Separate reports have been prepared for the other XRF instruments that were evaluated as part of the demonstration. The objectives of the evaluation included determining each XRF instrument’s accuracy, precision, sample throughput, and tendency for matrix effects. To fulfill these objectives, the field demonstration incorporated the analysis of 326 prepared samples of soil and sediment that contained 13 target elements. The prepared samples included blends of environmental samples from nine different sample collection sites as well as spiked samples with certified element concentrations. Accuracy

  7. Testing and Demonstrating Speaker Verification Technology in Iraqi-Arabic as Part of the Iraqi Enrollment Via Voice Authentication Project (IEVAP) in Support of the Global War on Terrorism (GWOT)

    National Research Council Canada - National Science Library

    Withee, Jeffrey W; Pena, Edwin D

    2007-01-01

    This thesis documents the findings of an Iraqi-Arabic language test and concept of operations for speaker verification technology as part of the Iraqi Banking System in support of the Iraqi Enrollment...

  8. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, GROUNDWATER SAMPLING TECHNOLOGIES, GEOPROBE INC., PNEUMATIC BLADDER PUMP GW 1400 SERIES

    Science.gov (United States)

    The U.S. Environmental Protection Agency (EPA) design efficient processes for conducting has created the Environmental Technology perfofl1lance tests of innovative technologies. Verification Program (E TV) to facilitate the deployment of innovative or improved environmental techn...

  9. AN ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) TESTING OF ENZYMATIC TEST KITS FOR WARFARE AGENTS AND PESTICIDES IN DRINKING WATER

    Science.gov (United States)

    Enzymatic test kits, generally designed to be handheld and portable, detect the presence of chemical agents, carbamate pesticides, and/or organophosphate pesticides by relying on the reaction of the cholinesterase enzyme. Under normal conditions, the enzyme reacts as expected wi...

  10. ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) PROGRAM: GREEN BUILDING TECHNOLOGIES

    Science.gov (United States)

    The U.S. Environmental Protection Agency (EPA) Environmental Technology Verification (ETV) Program evaluates the performance of innovative air, water, pollution prevention and monitoring technologies that have the potential to improve human health and the environment. This techno...

  11. Test/QA Plan for Verification of Cavity Ringdown Spectroscopy Systems for Ammonia Monitoring in Stack Gas

    Science.gov (United States)

    The purpose of the cavity ringdown spectroscopy (CRDS) technology test and quality assurance plan is to specify procedures for a verification test applicable to commercial cavity ringdown spectroscopy technologies. The purpose of the verification test is to evaluate the performa...

  12. Integrated testing and verification system for research flight software

    Science.gov (United States)

    Taylor, R. N.

    1979-01-01

    The MUST (Multipurpose User-oriented Software Technology) program is being developed to cut the cost of producing research flight software through a system of software support tools. An integrated verification and testing capability was designed as part of MUST. Documentation, verification and test options are provided with special attention on real-time, multiprocessing issues. The needs of the entire software production cycle were considered, with effective management and reduced lifecycle costs as foremost goals.

  13. GENERIC VERIFICATION PROTOCOL: DISTRIBUTED GENERATION AND COMBINED HEAT AND POWER FIELD TESTING PROTOCOL

    Science.gov (United States)

    This report is a generic verification protocol by which EPA’s Environmental Technology Verification program tests newly developed equipment for distributed generation of electric power, usually micro-turbine generators and internal combustion engine generators. The protocol will ...

  14. ENVIRONMENTAL TECHNOLOGY VERIFICATION: TEST REPORT OF MOBILE SOURCE EMISSION CONTROL DEVICES--PUREM NORTH AMERICA LLC, PMF GREENTEC 1004205.00.0 DIESEL PARTICULATE FILTER

    Science.gov (United States)

    The U.S. EPA has created the Environmental Technology Verification (ETV) program to provide high quality, peer reviewed data on technology performance to those involved in the design, distribution, financing, permitting, purchase, and use of environmental technologies. The Air Po...

  15. Technology for bolus verification in proton therapy

    Science.gov (United States)

    Shipulin, K. N.; Mytsin, G. V.; Agapov, A. V.

    2015-01-01

    To ensure the conformal depth-dose distribution of a proton beam within a target volume, complex shaped range shifters (so-called boluses), which account for the heterogeneous structure of patient tissue and organs in the beam path, were calculated and manufactured. The precise manufacturing of proton compensators used for patient treatment is a vital step in quality assurance in proton therapy. In this work a software-hardware complex that verifies the quality and precision of bolus manufacturing at the Medico-Technical Complex (MTC) was developed. The boluses consisted of a positioning system with two photoelectric biosensors. We evaluated 20 boluses used in proton therapy of five patients. A total number of 2562 experimental points were measured, of which only two points had values that differed from the calculated value by more than 0.5 mm. The other data points displayed a deviation within ±0.5 mm from the calculated value. The technology for bolus verification developed in this work can be used for the high precision testing of geometrical parameters of proton compensators in radiotherapy.

  16. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, REMOVAL OF ARSENIC IN DRINKING WATER: PHASE 1-ADI PILOT TEST UNIT NO. 2002-09 WITH MEDIA G2®

    Science.gov (United States)

    Integrity verification testing of the ADI International Inc. Pilot Test Unit No. 2002-09 with MEDIA G2® arsenic adsorption media filter system was conducted at the Hilltown Township Water and Sewer Authority (HTWSA) Well Station No. 1 in Sellersville, Pennsylvania from October 8...

  17. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, SHARPE MANUFACTURING TITANIUM T1-CG SPRAY GUN

    Science.gov (United States)

    Under EPA’s Environmental Technology Verification program, which provides objective and scientific third party analysis of new technology that can benefit the environment, the pollution prevention capabilities of a high transfer efficiency liquid spray gun was tested. This ...

  18. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, ANEST IWATA CORPORATION W400-LV SPRAY GUN

    Science.gov (United States)

    Under EPA’s Environmental Technology Verification program, which provides objective and scientific third party analysis of new technology that can benefit the environment, the pollution prevention capabilities of a high transfer efficiency liquid spray gun was tested. This ...

  19. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: BIOQUELL, INC. CLARIS C HYDROGEN PEROXIDE GAS GENERATOR

    Science.gov (United States)

    The Environmental Technology Verification report discusses the technology and performance of the Clarus C Hydrogen Peroxide Gas Generator, a biological decontamination device manufactured by BIOQUELL, Inc. The unit was tested by evaluating its ability to decontaminate seven types...

  20. Standardized Definitions for Code Verification Test Problems

    Energy Technology Data Exchange (ETDEWEB)

    Doebling, Scott William [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-09-14

    This document contains standardized definitions for several commonly used code verification test problems. These definitions are intended to contain sufficient information to set up the test problem in a computational physics code. These definitions are intended to be used in conjunction with exact solutions to these problems generated using Exact- Pack, www.github.com/lanl/exactpack.

  1. Enhanced Verification Test Suite for Physics Simulation Codes

    Energy Technology Data Exchange (ETDEWEB)

    Kamm, J R; Brock, J S; Brandon, S T; Cotrell, D L; Johnson, B; Knupp, P; Rider, W; Trucano, T; Weirs, V G

    2008-10-10

    This document discusses problems with which to augment, in quantity and in quality, the existing tri-laboratory suite of verification problems used by Los Alamos National Laboratory (LANL), Lawrence Livermore National Laboratory (LLNL), and Sandia National Laboratories (SNL). The purpose of verification analysis is demonstrate whether the numerical results of the discretization algorithms in physics and engineering simulation codes provide correct solutions of the corresponding continuum equations. The key points of this document are: (1) Verification deals with mathematical correctness of the numerical algorithms in a code, while validation deals with physical correctness of a simulation in a regime of interest. This document is about verification. (2) The current seven-problem Tri-Laboratory Verification Test Suite, which has been used for approximately five years at the DOE WP laboratories, is limited. (3) Both the methodology for and technology used in verification analysis have evolved and been improved since the original test suite was proposed. (4) The proposed test problems are in three basic areas: (a) Hydrodynamics; (b) Transport processes; and (c) Dynamic strength-of-materials. (5) For several of the proposed problems we provide a 'strong sense verification benchmark', consisting of (i) a clear mathematical statement of the problem with sufficient information to run a computer simulation, (ii) an explanation of how the code result and benchmark solution are to be evaluated, and (iii) a description of the acceptance criterion for simulation code results. (6) It is proposed that the set of verification test problems with which any particular code be evaluated include some of the problems described in this document. Analysis of the proposed verification test problems constitutes part of a necessary--but not sufficient--step that builds confidence in physics and engineering simulation codes. More complicated test cases, including physics models of

  2. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, REMOVAL OF ARSENIC IN DRINKING WATER: ADI INTERNATIONAL INC. ADI PILOT TEST UNIT NO. 2002-09 WITH MEDIA G2®; PHASE II

    Science.gov (United States)

    Verification testing of the ADI International Inc. Unit No. 2002-09 with MEDIA G2® arsenic adsorption media filter system was conducted at the Hilltown Township Water and Sewer Authority (HTWSA) Well Station No. 1 in Sellersville, Pennsylvania from October 8, 2003 through May 28,...

  3. Advanced Technologies for Design Information Verification

    Energy Technology Data Exchange (ETDEWEB)

    Watkins, Michael L.; Sheen, David M.; Rose, Joseph L.; Cumblidge, Stephen E.

    2009-07-08

    This paper discusses several technologies that have the potential to enhance facilities design verification. These approaches have shown promise in addressing the challenges associated with the verification of sub-component geometry and material composition for structures that are not directly accessible for physical inspection. A simple example is a pipe that extends into or through a wall or foundation. Both advanced electromagnetic and acoustic modalities will be discussed. These include advanced radar imaging, transient thermographic imaging, and guided acoustic wave imaging. Examples of current applications are provided. The basic principles and mechanisms of these inspection techniques are presented along with the salient practical features, advantages, and disadvantages of each technique. Other important considerations, such as component geometries, materials, and degree of access are also treated. The importance of, and strategies for, developing valid inspection models are also discussed. Beyond these basic technology adaptation and evaluation issues, important user interface considerations are outlined, along with approaches to quantify the overall performance reliability of the various inspection methods.

  4. Subsurface barrier verification technologies, informal report

    International Nuclear Information System (INIS)

    Heiser, J.H.

    1994-06-01

    One of the more promising remediation options available to the DOE waste management community is subsurface barriers. Some of the uses of subsurface barriers include surrounding and/or containing buried waste, as secondary confinement of underground storage tanks, to direct or contain subsurface contaminant plumes and to restrict remediation methods, such as vacuum extraction, to a limited area. To be most effective the barriers should be continuous and depending on use, have few or no breaches. A breach may be formed through numerous pathways including: discontinuous grout application, from joints between panels and from cracking due to grout curing or wet-dry cycling. The ability to verify barrier integrity is valuable to the DOE, EPA, and commercial sector and will be required to gain full public acceptance of subsurface barriers as either primary or secondary confinement at waste sites. It is recognized that no suitable method exists for the verification of an emplaced barrier's integrity. The large size and deep placement of subsurface barriers makes detection of leaks challenging. This becomes magnified if the permissible leakage from the site is low. Detection of small cracks (fractions of an inch) at depths of 100 feet or more has not been possible using existing surface geophysical techniques. Compounding the problem of locating flaws in a barrier is the fact that no placement technology can guarantee the completeness or integrity of the emplaced barrier. This report summarizes several commonly used or promising technologies that have been or may be applied to in-situ barrier continuity verification

  5. Advanced Technologies for Design Information Verification

    International Nuclear Information System (INIS)

    Watkins, Michael L.; Sheen, David M.; Rose, Joseph L.; Cumblidge, Stephen E.

    2009-01-01

    This paper discusses several technologies that have the potential to enhance facilities design verification. These approaches have shown promise in addressing the challenges associated with the verification of sub-component geometry and material composition for structures that are not directly accessible for physical inspection. A simple example is a pipe that extends into or through a wall or foundation. Both advanced electromagnetic and acoustic modalities will be discussed. These include advanced radar imaging, transient thermographic imaging, and guided acoustic wave imaging. Examples of current applications are provided. The basic principles and mechanisms of these inspection techniques are presented along with the salient practical features, advantages, and disadvantages of each technique. Other important considerations, such as component geometries, materials, and degree of access are also treated. The importance of, and strategies for, developing valid inspection models are also discussed. Beyond these basic technology adaptation and evaluation issues, important user interface considerations are outlined, along with approaches to quantify the overall performance reliability of the various inspection methods.

  6. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: EXEL INDUSTRIAL AIRMIX SPRAY GUN

    Science.gov (United States)

    The Environmental Technology Verification Program has partnered with Concurrent Technologies Corp. to verify innovative coatings and coating equipment technologies for reducing air emissions. This report describes the performance of EXEL Industrial's Kremlin Airmix high transfer ...

  7. FLUENT Test and Verification Document

    International Nuclear Information System (INIS)

    LEE, SI

    2006-01-01

    The FLUENT 6 CFD code has been benchmarked for a wide range of simple, classical, and complex physical problems associated with turbulent gas flow, natural convection, and turbulent mixing phenomena. The results validate the application of previous scoping calculations for the Tank 50/Tank 48 vapor space mixing. The benchmarked problems consisted of three groups. The first group was well-defined and classical problems for which analytical solutions exist. The other groups are complex and physical problems for which analytical solutions are difficult to obtain. For these test problems, CFD results were compared and verified through comparisons with experimental results. The benchmarking of the FLUENT 6 code showed that the code predictions are in good agreement with the analytical solutions or experimental test data. The code was shown to be sufficiently accurate to make reliable decisions based on calculated results for those applications that fall within the scope of the benchmarking test cases. For applications that fall outside the range of the benchmarking results, particularly for significantly higher benzene concentrations or for flow geometries not adequately represented by the κ-(var e psilon) turbulence model, further benchmarking work would be required

  8. Natural gas production verification tests

    International Nuclear Information System (INIS)

    1992-02-01

    This Environmental Assessment (EA) has been prepared by the Department of Energy (DOE) in compliance with the requirements of the National Environmental Policy Act of 1969. The Department of Energy (DOE) proposes to fund, through a contract with Petroleum Consulting Services, Inc. of Canton, Ohio, the testing of the effectiveness of a non-water based hydraulic fracturing treatment to increase gas recovery from low-pressure, tight, fractured Devonian Shale formations. Although Devonian Shales are found in the Appalachian, Michigan, and Illinois Basins, testing will be done only in the dominant, historical five state area of established production. The objective of this proposed project is to assess the benefits of liquid carbon dioxide (CO 2 )/sand stimulations in the Devonian Shale. In addition, this project would evaluate the potential nondamaging (to the formation) properties of this unique fracturing treatment relative to the clogging or chocking of pores and fractures that act as gas flow paths to the wellbore in the target gas-producing zones of the formation. This liquid CO 2 /sand fracturing process is water-free and is expected to facilitate gas well cleanup, reduce the time required for post-stimulation cleanup, and result in improved production levels in a much shorter time than is currently experienced

  9. SHINE Vacuum Pump Test Verification

    Energy Technology Data Exchange (ETDEWEB)

    Morgan, Gregg A; Peters, Brent

    2013-09-30

    Normetex pumps used world-wide for tritium service are no longer available. DOE and other researchers worldwide have spent significant funds characterizing this pump. Identification of alternate pumps is required for performance and compatibility with tritium gas. Many of the pumps that could be used to meet the functional performance requirements (e.g. pressure and flow conditions) of the Normetex pump have features that include the use of polymers or oils and greases that are not directly compatible with tritium service. This study assembles a test system to determine the flow characteristics for candidate alternate pumps. These tests are critical to the movement of tritium through the SHINE Tritium Purification System (TPS). The purpose of the pump testing is two-fold: (1) obtain baseline vacuum pump characteristics for an alternate (i.e. ''Normetex replacement'') pump intended for use in tritium service; and (2) verify that low pressure hydrogen gas can be transported over distances up to 300 feet by the candidate pumps. Flow rates and nominal system pressures have been identified for the SHINE Mo-99 production process Tritium Purification System (TPS). To minimize the line sizes for the transfer of low pressure tritium from the Neutron Driver Accelerator System (NDAS) to the primary processing systems in the TPS, a ''booster'' pump has been located near the accelerator in the design. A series of pump tests were performed at various configurations using hydrogen gas (no tritium) to ensure that this concept is practical and maintains adequate flow rates and required pressures. This report summarizes the results of the tests that have been performed using various pump configurations. The current design of the Tritium Purification System requires the ''booster'' pump to discharge to or to be backed by another vacuum pump. Since Normetex pumps are no longer manufactured, a commercially available Edwards

  10. Transparencies used in describing the CTBT verification regime and its four monitoring technologies

    International Nuclear Information System (INIS)

    Basham, P.

    1999-01-01

    This presentation includes description of the CTBT verification regime and its four monitoring technologies, (namely, seismic monitoring, hydro acoustic monitoring, infrasound monitoring and radionuclides monitoring) CTBT global verification system, sequence of steps needed for installing an international monitoring system station which includes: site survey, site preparation and construction, equipment procurement and installation, final tests and certification

  11. CIT photoheliograph functional verification unit test program

    Science.gov (United States)

    1973-01-01

    Tests of the 2/3-meter photoheliograph functional verification unit FVU were performed with the FVU installed in its Big Bear Solar Observatory vacuum chamber. Interferometric tests were run both in Newtonian (f/3.85) and Gregorian (f/50) configurations. Tests were run in both configurations with optical axis horizontal, vertical, and at 45 deg to attempt to determine any gravity effects on the system. Gravity effects, if present, were masked by scatter in the data associated with the system wavefront error of 0.16 lambda rms ( = 6328A) apparently due to problems in the primary mirror. Tests showed that the redesigned secondary mirror assembly works well.

  12. Consortium for Verification Technology Fellowship Report.

    Energy Technology Data Exchange (ETDEWEB)

    Sadler, Lorraine E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-06-01

    As one recipient of the Consortium for Verification Technology (CVT) Fellowship, I spent eight days as a visiting scientist at the University of Michigan, Department of Nuclear Engineering and Radiological Sciences (NERS). During this time, I participated in multiple department and research group meetings and presentations, met with individual faculty and students, toured multiple laboratories, and taught one-half of a one-unit class on Risk Analysis in Nuclear Arms control (six 1.5 hour lectures). The following report describes some of the interactions that I had during my time as well as a brief discussion of the impact of this fellowship on members of the consortium and on me/my laboratory’s technical knowledge and network.

  13. ENVIRONMENTAL TECHNOLOGY PROTOCOL VERIFICATION REPORT, EMISSIONS OF VOCS AND ALDEHYDES FROM COMMERCIAL FURNITURE (WITH APPENDICES)

    Science.gov (United States)

    As part of a U.S. Environmental Protection Agency Environmental Technology Verification program, the Research Triangle Institute (RTI) developed a test protocol for measuring volatile organic compounds and aldehydes in a large chamber. RTI convened stakeholders for the commercial...

  14. ENVIRONMENTAL TECHNOLOGY VERIFICATION: ALLIED PHOTOCHEMICAL KROHNZONE 7014 UV-CURABLE COATING

    Science.gov (United States)

    This Environmental Technology Verification report reports on reasearch done on a UV-curable automotive paint. The paint was tested for thickness, appearance, gloss, salt spray resistance, humidity resistance, adhesion, impact, mandrel bend, MEK rub, and abrasion resistance.

  15. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: NEW CONDENSATOR, INC.--THE CONDENSATOR DIESEL ENGINE RETROFIT CRANKCASE VENTILATION SYSTEM

    Science.gov (United States)

    EPA's Environmental Technology Verification Program has tested New Condensator Inc.'s Condensator Diesel Engine Retrofit Crankcase Ventilation System. Brake specific fuel consumption (BSFC), the ratio of engine fuel consumption to the engine power output, was evaluated for engine...

  16. Environmental Technology Verification Report: Taconic Energy, Inc. TEA Fuel Additive

    Science.gov (United States)

    The Greenhouse Gas Technology Center (GHG Center) is one of six verification organizations operating under EPA’s ETV program. One sector of significant interest to GHG Center stakeholders is transportation - particularly technologies that result in fuel economy improvements. Taco...

  17. ENVIRONMENTAL TECHNOLOGY VERIFICATION PROGRAM: PROTOCOL FOR THE VERIFICATION OF GROUTING MATERIALS FOR INFRASTRUCTURE REHABILITATION AT THE UNIVERSITY OF HOUSTON - CIGMAT

    Science.gov (United States)

    This protocol was developed under the Environmental Protection Agency's Environmental Technology Verification (ETV) Program, and is intended to be used as a guide in preparing laboratory test plans for the purpose of verifying the performance of grouting materials used for infra...

  18. System and Component Software Specification, Run-time Verification and Automatic Test Generation, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The following background technology is described in Part 5: Run-time Verification (RV), White Box Automatic Test Generation (WBATG). Part 5 also describes how WBATG...

  19. Design verification and cold-flow modeling test report

    Energy Technology Data Exchange (ETDEWEB)

    1993-07-01

    This report presents a compilation of the following three test reports prepared by TRW for Alaska Industrial Development and Export Authority (AIDEA) as part of the Healy Clean Coal Project, Phase 1 Design of the TRW Combustor and Auxiliary Systems, which is co-sponsored by the Department of Energy under the Clean Coal Technology 3 Program: (1) Design Verification Test Report, dated April 1993, (2) Combustor Cold Flow Model Report, dated August 28, 1992, (3) Coal Feed System Cold Flow Model Report, October 28, 1992. In this compilation, these three reports are included in one volume consisting of three parts, and TRW proprietary information has been excluded.

  20. Test/QA plan for the verification testing of selective catalytic reduction control technologies for highway, nonroad use heavy-duty diesel engines

    Science.gov (United States)

    This ETV test/QA plan for heavy-duty diesel engine testing at the Southwest Research Institute’s Department of Emissions Research (DER) describes how the Federal Test Procedure (FTP), as listed in 40 CFR Part 86 for highway engines and 40 CFR Part 89 for nonroad engines, will be ...

  1. Test/QA plan for the verification testing of diesel exhaust catalysts, particulate filters and engine modification control technologies for highway and nonroad use diesel engines

    Science.gov (United States)

    This ETV test/QA plan for heavy-duty diesel engine testing at the Southwest Research Institute’s Department of Emissions Research (DER) describes how the Federal Test Procedure (FTP), as listed in 40 CFR Part 86 for highway engines and 40 CFR Part 89 for nonroad engines, will be ...

  2. Fiscal 1997 report of the development of high efficiency waste power generation technology. No.2 volume. Pilot plant verification test; Kokoritsu haikibutsu hatsuden gijutsu kaihatsu (pilot plant jissho shiken). 1997 nendo hokokusho (daini bunsatsu)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    As to a high efficiency waste power generation system using general waste as fuel, the details of the following were described: design/construction management and operational study of pilot plant, design/manufacture/construction of pilot plant, and study of an optimal total system. Concerning the construction management and operational study, the paper described the application for governmental/official inspection procedures and taking inspection, process management of pilot plant, site patrol, safety management, management of trial run of pilot plant, drawing-up of a verification test plan and test run, etc. Relating to the design/manufacture/construction of pilot plant, an outline of the pilot plant was described. The paper also stated points to be considered in design of furnace structure and boiler structure, points to be considered of the verification test, etc. As to the study of an optimal total system, the following were described: survey of waste gasification/slagging power generation technology, basic study on RDF production process, survey of trends of waste power generation technology in the U.S., etc. 52 refs., 149 figs., 121 tabs.

  3. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT LASER TOUCH AND TECHNOLOGIES, LLC LASER TOUCH MODEL LT-B512

    Science.gov (United States)

    The Environmental Technology Verification report discusses the technology and performance of Laser Touch model LT-B512 targeting device manufactured by Laser Touch and Technologies, LLC, for manual spray painting operations. The relative transfer efficiency (TE) improved an avera...

  4. Test/QA Plan For Verification Of Anaerobic Digester For Energy Production And Pollution Prevention

    Science.gov (United States)

    The ETV-ESTE Program conducts third-party verification testing of commercially available technologies that improve the environmental conditions in the U.S. A stakeholder committee of buyers and users of such technologies guided the development of this test on anaerobic digesters...

  5. Testing Conducted for Lithium-Ion Cell and Battery Verification

    Science.gov (United States)

    Reid, Concha M.; Miller, Thomas B.; Manzo, Michelle A.

    2004-01-01

    The NASA Glenn Research Center has been conducting in-house testing in support of NASA's Lithium-Ion Cell Verification Test Program, which is evaluating the performance of lithium-ion cells and batteries for NASA mission operations. The test program is supported by NASA's Office of Aerospace Technology under the NASA Aerospace Flight Battery Systems Program, which serves to bridge the gap between the development of technology advances and the realization of these advances into mission applications. During fiscal year 2003, much of the in-house testing effort focused on the evaluation of a flight battery originally intended for use on the Mars Surveyor Program 2001 Lander. Results of this testing will be compared with the results for similar batteries being tested at the Jet Propulsion Laboratory, the Air Force Research Laboratory, and the Naval Research Laboratory. Ultimately, this work will be used to validate lithium-ion battery technology for future space missions. The Mars Surveyor Program 2001 Lander battery was characterized at several different voltages and temperatures before life-cycle testing was begun. During characterization, the battery displayed excellent capacity and efficiency characteristics across a range of temperatures and charge/discharge conditions. Currently, the battery is undergoing lifecycle testing at 0 C and 40-percent depth of discharge under low-Earth-orbit (LEO) conditions.

  6. Environmental Technology Verification Report - Electric Power and Heat Production Using Renewable Biogas at Patterson Farms

    Science.gov (United States)

    The U.S. EPA operates the Environmental Technology Verification program to facilitate the deployment of innovative technologies through performance verification and information dissemination. A technology area of interest is distributed electrical power generation, particularly w...

  7. Technical workshop on safeguards, verification technologies, and other related experience

    International Nuclear Information System (INIS)

    1998-01-01

    The aim of the Technical Workshop on safeguards was to encourage a clearer understanding of the IAEA Safeguards System, its origins and evolution and the present state of the art. Presentations held by the IAEA officials and outside experts examined as well other components of the non-proliferation regime, the current practices and procedures, and the future prospects. A series of presentations described the characteristics of the interaction between global and regional verification systems and described relevant past and present experience. Prominence given to such state of the art verification technologies as environmental sampling, satellite imaging and monitoring thorough remote and unattended techniques demonstrated, beyond any doubt, the essentially dynamic nature of verification. It is generally acknowledged that there have been major achievements in preventing spread of nuclear weapons, but no verification system can in itself prevent proliferation

  8. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT - BAGHOUSE FILTRATION PRODUCTS - TETRATEC PTFE TECHNOLOGIES TETRATEX 8005

    Science.gov (United States)

    Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of th...

  9. TET-1- A German Microsatellite for Technology On -Orbit Verification

    Science.gov (United States)

    Föckersperger, S.; Lattner, K.; Kaiser, C.; Eckert, S.; Bärwald, W.; Ritzmann, S.; Mühlbauer, P.; Turk, M.; Willemsen, P.

    2008-08-01

    Due to the high safety standards in the space industry every new product must go through a verification process before qualifying for operation in a space system. Within the verification process the payload undergoes a series of tests which prove that it is in accordance with mission requirements in terms of function, reliability and safety. Important verification components are the qualification for use on the ground as well as the On-Orbit Verification (OOV), i.e. proof that the product is suitable for use under virtual space conditions (on-orbit). Here it is demonstrated that the product functions under conditions which cannot or can only be partially simulated on the ground. The OOV-Program of the DLR serves to bridge the gap between the product tested and qualified on the ground and the utilization of the product in space. Due to regular and short-term availability of flight opportunities industry and research facilities can verify their latest products under space conditions and demonstrate their reliability and marketability. The Technologie-Erprobungs-Tr&äger TET (Technology Experiments Carrier) comprises the core elements of the OOV Program. A programmatic requirement of the OOV Program is that a satellite bus already verified in orbit be used in the first segment of the program. An analysis of suitable satellite buses showed that a realization of the TET satellite bus based on the BIRD satellite bus fulfilled the programmatic requirements best. Kayser-Threde was selected by DLR as Prime Contractor to perform the project together with its major subcontractors Astro- und Feinwerktechnik, Berlin for the platform development and DLR-GSOC for the ground segment development. TET is now designed to be a modular and flexible micro-satellite for any orbit between 450 and 850 km altitude and inclination between 53° and SSO. With an overall mass of 120 kg TET is able to accommodate experiments of up to 50 kg. A multipurpose payload supply systemThere is

  10. Technology verification phase. Dynamic isotope power system. Final report

    International Nuclear Information System (INIS)

    Halsey, D.G.

    1982-01-01

    The Phase I requirements of the Kilowatt Isotope Power System (KIPS) program were to make a detailed Flight System Conceptual Design (FSCD) for an isotope fueled organic Rankine cycle power system and to build and test a Ground Demonstration System (GDS) which simulated as closely as possible the operational characteristics of the FSCD. The activities and results of Phase II, the Technology Verification Phase, of the program are reported. The objectives of this phase were to increase system efficiency to 18.1% by component development, to demonstrate system reliability by a 5000 h endurance test and to update the flight system design. During Phase II, system performance was improved from 15.1% to 16.6%, an endurance test of 2000 h was performed while the flight design analysis was limited to a study of the General Purpose Heat Source, a study of the regenerator manufacturing technique and analysis of the hardness of the system to a laser threat. It was concluded from these tests that the GDS is basically prototypic of a flight design; all components necessary for satisfactory operation were demonstrated successfully at the system level; over 11,000 total h of operation without any component failure attested to the inherent reliability of this type of system; and some further development is required, specifically in the area of performance

  11. Technology verification phase. Dynamic isotope power system. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Halsey, D.G.

    1982-03-10

    The Phase I requirements of the Kilowatt Isotope Power System (KIPS) program were to make a detailed Flight System Conceptual Design (FSCD) for an isotope fueled organic Rankine cycle power system and to build and test a Ground Demonstration System (GDS) which simulated as closely as possible the operational characteristics of the FSCD. The activities and results of Phase II, the Technology Verification Phase, of the program are reported. The objectives of this phase were to increase system efficiency to 18.1% by component development, to demonstrate system reliability by a 5000 h endurance test and to update the flight system design. During Phase II, system performance was improved from 15.1% to 16.6%, an endurance test of 2000 h was performed while the flight design analysis was limited to a study of the General Purpose Heat Source, a study of the regenerator manufacturing technique and analysis of the hardness of the system to a laser threat. It was concluded from these tests that the GDS is basically prototypic of a flight design; all components necessary for satisfactory operation were demonstrated successfully at the system level; over 11,000 total h of operation without any component failure attested to the inherent reliability of this type of system; and some further development is required, specifically in the area of performance. (LCL)

  12. Dynamic Isotope Power System: technology verification phase, program plan, 1 October 1978

    International Nuclear Information System (INIS)

    1979-01-01

    The technology verification phase program plan of the Dynamic Isotope Power System (DIPS) project is presented. DIPS is a project to develop a 0.5 to 2.0 kW power system for spacecraft using an isotope heat source and a closed-cycle Rankine power-system with an organic working fluid. The technology verification phase's purposes are to increase the system efficiency to over 18%, to demonstrate system reliability, and to provide an estimate for flight test scheduling. Progress toward these goals is reported

  13. Debris Detector Verification by Hvi-Tests

    Science.gov (United States)

    Bauer, Waldemar; Drolshagen, Gerhard; Vörsmann, Peter; Romberg, Oliver; Putzar, Robin

    impact detection. Considering that the SOLID method could be applied to several S/Cs in different orbits, the spatial coverage in space concerning SD and MM can be significantly increased. In this way the method allows to generate large amount of impact data, which can be used for environmental model validation. This paper focuses on the verification of the SOLID method by Hypervelocity Impact (HVI) tests performed at Fraunhofer EMI. The test set-up as well as achieved results are presented and discussed.

  14. Test/QA Plan for Verification of Radio Frequency Identification (RFID) for Tracking Hazardous Waste Shipments across International Borders

    Science.gov (United States)

    The verification test will be conducted under the auspices of the U.S. Environmental Protection Agency (EPA) through the Environmental Technology Verification (ETV) Program. It will be performed by Battelle, which is managing the ETV Advanced Monitoring Systems (AMS) Center throu...

  15. DIESEL ENGINE RETROFIT TECHNOLOGY VERIFICATION (POSTER)

    Science.gov (United States)

    ETV is presenting a poster at the EPA's 2005 Science Forum from May 16-18, 2005 in Washington, DC. This poster will contain a summary of the performance results realized by the six verified diesel retrofit technologies, as well as potential impacts that could be realized if sigi...

  16. Development of evaluation and performance verification technology for radiotherapy radiation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. Y.; Jang, S. Y.; Kim, B. H. and others

    2005-02-15

    No matter how much the importance is emphasized, the exact assessment of the absorbed doses administered to the patients to treat the various diseases such as lately soaring malignant tumors with the radiotherapy practices is the most important factor. In reality, several over-exposed patients from the radiotherapy practice become very serious social issues. Especially, the development of a technology to exactly assess the high doses and high energies (In general, dose administered to the patients with the radiotherapy practices are very huge doses, and they are about three times higher than the lethal doses) generated by the radiation generators and irradiation equipment is a competing issue to be promptly conducted. Over fifty medical centers in Korea operate the radiation generators and irradiation equipment for the radiotherapy practices. However, neither the legal and regulatory systems to implement a quality assurance program are sufficiently stipulated nor qualified personnel who could run a program to maintain the quality assurance and control of those generators and equipment for the radiotherapy practices in the medical facilities are sufficiently employed. To overcome the above deficiencies, a quality assurance program such as those developed in the technically advanced countries should be developed to exactly assess the doses administered to patients with the radiotherapy practices and develop the necessary procedures to maintain the continuing performance of the machine or equipment for the radiotherapy. The QA program and procedures should induce the fluent calibration of the machine or equipment with quality, and definitely establish the safety of patients in the radiotherapy practices. In this study, a methodology for the verification and evaluation of the radiotherapy doses is developed, and several accurate measurements, evaluations of the doses delivered to patients and verification of the performance of the therapy machine and equipment are

  17. Design verification testing for fuel element type CAREM

    International Nuclear Information System (INIS)

    Martin Ghiselli, A.; Bonifacio Pulido, K.; Villabrille, G.; Rozembaum, I.

    2013-01-01

    The hydraulic and hydrodynamic characterization tests are part of the design verification process of a nuclear fuel element prototype and its components. These tests are performed in a low pressure and temperature facility. The tests requires the definition of the simulation parameters for setting the test conditions, the results evaluation to feedback mathematical models, extrapolated the results to reactor conditions and finally to decide the acceptability of the tested prototype. (author)

  18. Sierra/SolidMechanics 4.48 Verification Tests Manual.

    Energy Technology Data Exchange (ETDEWEB)

    Plews, Julia A.; Crane, Nathan K; de Frias, Gabriel Jose; Le, San; Littlewood, David John; Merewether, Mark Thomas; Mosby, Matthew David; Pierson, Kendall H.; Porter, Vicki L.; Shelton, Timothy; Thomas, Jesse David; Tupek, Michael R.; Veilleux, Michael; Xavier, Patrick G.

    2018-03-01

    Presented in this document is a small portion of the tests that exist in the Sierra / SolidMechanics (Sierra / SM) verification test suite. Most of these tests are run nightly with the Sierra / SM code suite, and the results of the test are checked versus the correct analytical result. For each of the tests presented in this document, the test setup, a description of the analytic solution, and comparison of the Sierra / SM code results to the analytic solution is provided. Mesh convergence is also checked on a nightly basis for several of these tests. This document can be used to confirm that a given code capability is verified or referenced as a compilation of example problems. Additional example problems are provided in the Sierra / SM Example Problems Manual. Note, many other verification tests exist in the Sierra / SM test suite, but have not yet been included in this manual.

  19. Environmental Technology Verification: Test Report of Mobile Source Emission Control Devices--Johnson Matthey PCRT2 1000, Version 2, Filter + Diesel Oxidation Catalyst

    Science.gov (United States)

    The Johnson Matthey PCRT2 1000, v.2 system is a partial continuously regenerating technology (PCRT) system that consists of a flow-through partial filter combined with a DOC. The system is designed for low temperature exhaust resulting from intermittent loads from medium and heav...

  20. Environmental Technology Verification Report and Statement for Baghouse Filtration Products, W. L. Gore & Associates, Inc. 5117 High Durability PPS Laminate Filtration Media (Tested March-April 2012)

    Science.gov (United States)

    Baghouses are air pollution control devices used to control particulate emissions from stationary sources and are among the technologies evaluated by the APCT Center. Baghouses and their accompanying filter media have long been one of the leading particulate control techniques fo...

  1. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, SWINE WASTE ELECTRIC POWER AND HEAT PRODUCTION--MARTIN MACHINERY INTERNAL COMBUSTION ENGINE

    Science.gov (United States)

    Under EPA’s Environmental Technology Verification program, which provides objective and scientific third party analysis of new technology that can benefit the environment, a combined heat and power system designed by Martin Machinery was evaluated. This paper provides test result...

  2. IMOM Field Test Study and Accuracy Verification

    National Research Council Canada - National Science Library

    Levien, Fred

    1998-01-01

    .... It was desired to obtain flight test data for both TAMPS and IMOM in order to compare their ability to accurately predict the effects of Radar Terrain Masking (RTM). It was initially planned to have NPS compare predictive data from both of these systems and then do analysis of how they compared to actual field test data.

  3. Application verification research of cloud computing technology in the field of real time aerospace experiment

    Science.gov (United States)

    Wan, Junwei; Chen, Hongyan; Zhao, Jing

    2017-08-01

    According to the requirements of real-time, reliability and safety for aerospace experiment, the single center cloud computing technology application verification platform is constructed. At the IAAS level, the feasibility of the cloud computing technology be applied to the field of aerospace experiment is tested and verified. Based on the analysis of the test results, a preliminary conclusion is obtained: Cloud computing platform can be applied to the aerospace experiment computing intensive business. For I/O intensive business, it is recommended to use the traditional physical machine.

  4. Advanced Communication Technology Satellite (ACTS) multibeam antenna technology verification experiments

    Science.gov (United States)

    Acosta, Roberto J.; Larko, Jeffrey M.; Lagin, Alan R.

    1992-01-01

    The Advanced Communication Technology Satellite (ACTS) is a key to reaching NASA's goal of developing high-risk, advanced communications technology using multiple frequency bands to support the nation's future communication needs. Using the multiple, dynamic hopping spot beams, and advanced on board switching and processing systems, ACTS will open a new era in communications satellite technology. One of the key technologies to be validated as part of the ACTS program is the multibeam antenna with rapidly reconfigurable hopping and fixed spot beam to serve users equipped with small-aperature terminals within the coverage areas. The proposed antenna technology experiments are designed to evaluate in-orbit ACTS multibeam antenna performance (radiation pattern, gain, cross pol levels, etc.).

  5. ENVIRONMENTAL TECHNOLOGY VERIFICATION--FUELCELL ENERGY, INC.: DFC 300A MOLTEN CARBONATE FUEL CELL COMBINED HEAT AND POWER SYSTEM

    Science.gov (United States)

    The U.S. EPA operates the Environmental Technology Verification program to facilitate the deployment of innovative technologies through performance verification and information dissemination. A technology area of interest is distributed electrical power generation, particularly w...

  6. A verification system survival probability assessment model test methods

    International Nuclear Information System (INIS)

    Jia Rui; Wu Qiang; Fu Jiwei; Cao Leituan; Zhang Junnan

    2014-01-01

    Subject to the limitations of funding and test conditions, the number of sub-samples of large complex system test less often. Under the single sample conditions, how to make an accurate evaluation of the performance, it is important for reinforcement of complex systems. It will be able to significantly improve the technical maturity of the assessment model, if that can experimental validation and evaluation model. In this paper, a verification system survival probability assessment model test method, the method by the test system sample test results, verify the correctness of the assessment model and a priori information. (authors)

  7. CIVET: Continuous Integration, Verification, Enhancement, and Testing

    Energy Technology Data Exchange (ETDEWEB)

    2016-11-29

    A Git server (GitHub, GitLab, BitBucket) sends event notifications to the Civet server. These are either a " Pull Request" or a "Push" notification. Civet then checks the database to determine what tests need to be run and marks them as ready to run. Civet clients, running on dedicated machines, query the server for available jobs that are ready to run. When a client gets a job it executes the scripts attached to the job and report back to the server the output and exit status. When the client updates the server, the server will also update the Git server with the result of the job, as well as updating the main web page.

  8. Workgroup for Hydraulic laboratory Testing and Verification of Hydroacoustic Instrumentation

    Science.gov (United States)

    Fulford, Janice M.; Armstrong, Brandy N.; Thibodeaux, Kirk G.

    2015-01-01

    An international workgroup was recently formed for hydraulic laboratory testing and verification of hydroacoustic instrumentation used for water velocity measurements. The activities of the workgroup have included one face to face meeting, conference calls and an inter-laboratory exchange of two acoustic meters among participating laboratories. Good agreement was found among four laboratories at higher tow speeds and poorer agreement at the lowest tow speed.

  9. US monitoring and verification technology: on-site inspection experience and future challenges

    International Nuclear Information System (INIS)

    Gullickson, R.L.; Carlson, D.; Ingraham, J.; Laird, B.

    2013-01-01

    The United States has a long and successful history of cooperation with treaty partners in monitoring and verification. For strategic arms reduction treaties, our collaboration has resulted in the development and application of systems with limited complexity and intrusiveness. As we progress beyond New START (NST) along the 'road to zero', the reduced number of nuclear weapons is likely to require increased confidence in monitoring and verification techniques. This may place increased demands on the technology to verify the presence of a nuclear weapon and even confirm the presence of a certain type. Simultaneously, this technology must include the ability to protect each treaty partner's sensitive nuclear weapons information. Mutual development of this technology by treaty partners offers the best approach for acceptance in treaty negotiations. This same approach of mutual cooperation and development is essential for developing nuclear test monitoring technology in support of the Comprehensive Nuclear Test Ban Treaty (CTBT). Our ability to detect low yield and evasive testing will be enhanced through mutually developed techniques and experiments using laboratory laser experiments and high explosives tests in a variety of locations and geologies. (authors)

  10. Task Force Report: Assessment of Nuclear Monitoring and Verification Technologies

    Science.gov (United States)

    2014-01-01

    UNCLASSIFIED  Recommendation:  State/Bureau  of  Arms  Control,  Verification  and  Compliance  ( AVC )  (diplomatic), DOE/National Nuclear Security...Department.     Recommendation:  State/ AVC ,  DOE/NNSA,  and  DoD/Acquisition,  Technology,  and  Logistics  (AT&L)  should  review  current U.S.  facility...agencies, State/ AVC , ASD(NCB), NNSA and NCPC should create  the processes and oversee the following steps:       Establish  a  “White  Team”  whose

  11. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT - BAGHOUSE FILTRATION PRODUCTS - MENARDI-CRISWELL 50-504 FILTER SAMPLE

    Science.gov (United States)

    Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of th...

  12. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT - BAGHOUSE FILTRATION PRODUCTS - STANDARD FILTER CORPORATION PE16ZU FILTER SAMPLE

    Science.gov (United States)

    Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of th...

  13. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT - BAGHOUSE FILTRATION PRODUCTS - INSPEC FIBRES 5512BRF FILTER SAMPLE

    Science.gov (United States)

    Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of th...

  14. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT - BAGHOUSE FILTRATION PRODUCTS - AIR PURATOR CORPORATION HUYGLAS 1405M FILTER SAMPLE

    Science.gov (United States)

    Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of th...

  15. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT - BAGHOUSE FILTRATION PRODUCTS - BHA GROUP, INC. QG061 FILTER SAMPLE

    Science.gov (United States)

    Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of th...

  16. Technique for unit testing of safety software verification and validation

    International Nuclear Information System (INIS)

    Li Duo; Zhang Liangju; Feng Junting

    2008-01-01

    The key issue arising from digitalization of the reactor protection system for nuclear power plant is how to carry out verification and validation (V and V), to demonstrate and confirm the software that performs reactor safety functions is safe and reliable. One of the most important processes for software V and V is unit testing, which verifies and validates the software coding based on concept design for consistency, correctness and completeness during software development. The paper shows a preliminary study on the technique for unit testing of safety software V and V, focusing on such aspects as how to confirm test completeness, how to establish test platform, how to develop test cases and how to carry out unit testing. The technique discussed here was successfully used in the work of unit testing on safety software of a digital reactor protection system. (authors)

  17. The concept verification testing of materials science payloads

    Science.gov (United States)

    Griner, C. S.; Johnston, M. H.; Whitaker, A.

    1976-01-01

    The concept Verification Testing (CVT) project at the Marshall Space Flight Center, Alabama, is a developmental activity that supports Shuttle Payload Projects such as Spacelab. It provides an operational 1-g environment for testing NASA and other agency experiment and support systems concepts that may be used in shuttle. A dedicated Materials Science Payload was tested in the General Purpose Laboratory to assess the requirements of a space processing payload on a Spacelab type facility. Physical and functional integration of the experiments into the facility was studied, and the impact of the experiments on the facility (and vice versa) was evaluated. A follow-up test designated CVT Test IVA was also held. The purpose of this test was to repeat Test IV experiments with a crew composed of selected and trained scientists. These personnel were not required to have prior knowledge of the materials science disciplines, but were required to have a basic knowledge of science and the scientific method.

  18. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT - BAGHOUSE FILTRATION PRODUCTS - ALBANY INTERNATIONAL CORP. INDUSTRIAL PROCESS TECHNOLOGIES PRIMATEX PLUS I FILTER SAMPLE

    Science.gov (United States)

    Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of th...

  19. Cassini's Test Methodology for Flight Software Verification and Operations

    Science.gov (United States)

    Wang, Eric; Brown, Jay

    2007-01-01

    The Cassini spacecraft was launched on 15 October 1997 on a Titan IV-B launch vehicle. The spacecraft is comprised of various subsystems, including the Attitude and Articulation Control Subsystem (AACS). The AACS Flight Software (FSW) and its development has been an ongoing effort, from the design, development and finally operations. As planned, major modifications to certain FSW functions were designed, tested, verified and uploaded during the cruise phase of the mission. Each flight software upload involved extensive verification testing. A standardized FSW testing methodology was used to verify the integrity of the flight software. This paper summarizes the flight software testing methodology used for verifying FSW from pre-launch through the prime mission, with an emphasis on flight experience testing during the first 2.5 years of the prime mission (July 2004 through January 2007).

  20. Integrated testing and verification system for research flight software design document

    Science.gov (United States)

    Taylor, R. N.; Merilatt, R. L.; Osterweil, L. J.

    1979-01-01

    The NASA Langley Research Center is developing the MUST (Multipurpose User-oriented Software Technology) program to cut the cost of producing research flight software through a system of software support tools. The HAL/S language is the primary subject of the design. Boeing Computer Services Company (BCS) has designed an integrated verification and testing capability as part of MUST. Documentation, verification and test options are provided with special attention on real time, multiprocessing issues. The needs of the entire software production cycle have been considered, with effective management and reduced lifecycle costs as foremost goals. Capabilities have been included in the design for static detection of data flow anomalies involving communicating concurrent processes. Some types of ill formed process synchronization and deadlock also are detected statically.

  1. Pilot-scale verification test for Hanford grout

    International Nuclear Information System (INIS)

    Bagaasen, L.M.; Powell, W.J.

    1993-02-01

    The Grout Treatment Facility (GTF) at Hanford, Washington will process the low-level fraction of selected double-shell tank (DST) wastes on the Hanford Site, to produce a cementitious waste form. This facility, which is operated by Westinghouse Hanford Company (Westinghouse Hanford), mixes liquid wastes with cementitious materials and pumps the resulting grout slurry into large [5,300 cubic meters (m 3 )] concrete vaults. Once in the vault, the grout cures to produce a waste form that immobilizes radioactive and hazardous constituents through chemical reactions and/or microencapsulation. Although this disposal scheme has several advantages, pouring grout into large vaults raises concerns about how to handle the heat generated from the exothermic hydration reactions that occur as the grout cures. WHC's current strategy for addressing the problem of hydration heat is to fill the vault in stages and use forced ventilation in the airspace above the grout to speed heat removal. The varying composition of Hanford tank waste requires that each tank be processed in a separate campaign using a grout formulation specifically designed for that waste. The next tank scheduled for treatment is DST 241-AN-106. A four-phase process for developing the grout formulation development process is used to assure that the formulation will meet various processing and waste form requirements. These phases are: (1) laboratory formulation development studies and modeling with simulated wastes, (2) laboratory variability studies with simulated waste, (3) pilot-scale verification tests with simulated wastes, and (4) laboratory verification tests with actual waste. This paper presents an overview of the pilot-scale verification tests conducted as part of the grout formulation development for the 241-AN-106 tank waste. The paper specifically discusses results dealing with (1) the grout slurry critical flow rate and (2) the ability to handle grout hydration heat with forced ventilation

  2. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: MOBILE SOURCE RETROFIT AIR POLLUTION CONTROL DEVICES: CLEAN CLEAR FUEL TECHNOLOGIES, INC.’S, UNIVERSAL FUEL CELL

    Science.gov (United States)

    The U.S. EPA's Office of Research and Development operates the Environmental Technology Verification (ETV) program to facilitate the deployment of innovative technologies through performance verification and information dissemination. Congress funds ETV in response to the belief ...

  3. NASA's Evolutionary Xenon Thruster (NEXT) Component Verification Testing

    Science.gov (United States)

    Herman, Daniel A.; Pinero, Luis R.; Sovey, James S.

    2009-01-01

    Component testing is a critical facet of the comprehensive thruster life validation strategy devised by the NASA s Evolutionary Xenon Thruster (NEXT) program. Component testing to-date has consisted of long-duration high voltage propellant isolator and high-cycle heater life validation testing. The high voltage propellant isolator, a heritage design, will be operated under different environmental condition in the NEXT ion thruster requiring verification testing. The life test of two NEXT isolators was initiated with comparable voltage and pressure conditions with a higher temperature than measured for the NEXT prototype-model thruster. To date the NEXT isolators have accumulated 18,300 h of operation. Measurements indicate a negligible increase in leakage current over the testing duration to date. NEXT 1/2 in. heaters, whose manufacturing and control processes have heritage, were selected for verification testing based upon the change in physical dimensions resulting in a higher operating voltage as well as potential differences in thermal environment. The heater fabrication processes, developed for the International Space Station (ISS) plasma contactor hollow cathode assembly, were utilized with modification of heater dimensions to accommodate a larger cathode. Cyclic testing of five 1/22 in. diameter heaters was initiated to validate these modified fabrication processes while retaining high reliability heaters. To date two of the heaters have been cycled to 10,000 cycles and suspended to preserve hardware. Three of the heaters have been cycled to failure giving a B10 life of 12,615 cycles, approximately 6,000 more cycles than the established qualification B10 life of the ISS plasma contactor heaters.

  4. Computer Forensic Function Testing: Media Preparation, Write Protection And Verification

    Directory of Open Access Journals (Sweden)

    Yinghua (David Guo

    2010-06-01

    Full Text Available Normal 0 false false false EN-US JA AR-SA The growth in the computer forensic field has created a demand for new software (or increased functionality to existing software and a means to verify that this software is truly forensic i.e. capable of meeting the requirements of the trier of fact. In this work, we review our previous work---a function oriented testing framework for validation and verification of computer forensic tools. This framework consists of three parts: function mapping, requirements specification and reference set development. Through function mapping, we give a scientific and systemical description of the fundamentals of computer forensic discipline, i.e. what functions are needed in the computer forensic investigation process. We focus this paper on the functions of media preparation, write protection and verification. Specifically, we complete the function mapping of these functions and specify their requirements. Based on this work, future work can be conducted to develop corresponding reference sets to test any tools that possess these functions.

  5. Integrating Requirements Engineering, Modeling, and Verification Technologies into Software and Systems Engineering

    National Research Council Canada - National Science Library

    Broy, Manfred; Leucker, Martin

    2007-01-01

    The objective of this project is the development of an integrated suite of technologies focusing on end-to-end software development supporting requirements analysis, design, implementation, and verification...

  6. Verification Test of Hydraulic Performance for Reactor Coolant Pump

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sang Jun; Kim, Jae Shin; Ryu, In Wan; Ko, Bok Seong; Song, Keun Myung [Samjin Ind. Co., Seoul (Korea, Republic of)

    2010-01-15

    According to this project, basic design for prototype pump and model pump of reactor coolant pump and test facilities has been completed. Basic design for prototype pump to establish structure, dimension and hydraulic performance has been completed and through primary flow analysis by computational fluid dynamics(CFD), flow characteristics and hydraulic performance have been established. This pump was designed with mixed flow pump having the following design requirements; specific velocity(Ns); 1080.9(rpm{center_dot}m{sup 3}/m{center_dot}m), capacity; 3115m{sup 3}/h, total head ; 26.3m, pump speed; 1710rpm, pump efficiency; 77.0%, Impeller out-diameter; 349mm, motor output; 360kw, design pressure; 17MPaG. The features of the pump are leakage free due to no mechanical seal on the pump shaft which insures reactor's safety and law noise level and low vibration due to no cooling fan on the motor which makes eco-friendly product. Model pump size was reduced to 44% of prototype pump for the verification test for hydraulic performance of reactor coolant pump and was designed with mixed flow pump and canned motor having the following design requirements; specific speed(NS); 1060.9(rpm{center_dot}m{sup 3}/m{center_dot}m), capacity; 539.4m{sup 3}/h, total head; 21.0m, pump speed; 3476rpm, pump efficiency; 72.9%, Impeller out-diameter; 154mm, motor output; 55kw, design pressure; 1.0MPaG. The test facilities were designed for verification test of hydraulic performance suitable for pump performance test, homologous test, NPSH test(cavitation), cost down test and pressure pulsation test of inlet and outlet ports. Test tank was designed with testing capacity enabling up to 2000m{sup 3}/h and design pressure 1.0MPaG. Auxiliary pump was designed with centrifugal pump having capacity; 1100m{sup 3}/h, total head; 42.0m, motor output; 190kw

  7. Technology and testing.

    Science.gov (United States)

    Quellmalz, Edys S; Pellegrino, James W

    2009-01-02

    Large-scale testing of educational outcomes benefits already from technological applications that address logistics such as development, administration, and scoring of tests, as well as reporting of results. Innovative applications of technology also provide rich, authentic tasks that challenge the sorts of integrated knowledge, critical thinking, and problem solving seldom well addressed in paper-based tests. Such tasks can be used on both large-scale and classroom-based assessments. Balanced assessment systems can be developed that integrate curriculum-embedded, benchmark, and summative assessments across classroom, district, state, national, and international levels. We discuss here the potential of technology to launch a new era of integrated, learning-centered assessment systems.

  8. Software Testing and Verification in Climate Model Development

    Science.gov (United States)

    Clune, Thomas L.; Rood, RIchard B.

    2011-01-01

    Over the past 30 years most climate models have grown from relatively simple representations of a few atmospheric processes to a complex multi-disciplinary system. Computer infrastructure over that period has gone from punch card mainframes to modem parallel clusters. Model implementations have become complex, brittle, and increasingly difficult to extend and maintain. Existing verification processes for model implementations rely almost exclusively upon some combination of detailed analysis of output from full climate simulations and system-level regression tests. In additional to being quite costly in terms of developer time and computing resources, these testing methodologies are limited in terms of the types of defects that can be detected, isolated and diagnosed. Mitigating these weaknesses of coarse-grained testing with finer-grained "unit" tests has been perceived as cumbersome and counter-productive. In the commercial software sector, recent advances in tools and methodology have led to a renaissance for systematic fine-grained testing. We discuss the availability of analogous tools for scientific software and examine benefits that similar testing methodologies could bring to climate modeling software. We describe the unique challenges faced when testing complex numerical algorithms and suggest techniques to minimize and/or eliminate the difficulties.

  9. Development of a Torque Sensor-Based Test Bed for Attitude Control System Verification and Validation

    Science.gov (United States)

    2017-12-30

    AFRL-RV-PS- AFRL-RV-PS- TR-2018-0008 TR-2018-0008 DEVELOPMENT OF A TORQUE SENSOR - BASED TEST BED FOR ATTITUDE CONTROL SYSTEM VERIFICATION AND... Sensor -Based Test Bed for Attitude Control System Verification & Validation 5a. CONTRACT NUMBER FA9453-15-1-0315 5b. GRANT NUMBER 5c. PROGRAM ELEMENT...covers the development of a torque sensor for verification and validation (V&V) of spacecraft attitude control actuators. The developed sensor directly

  10. Recent trends on Software Verification and Validation Testing

    International Nuclear Information System (INIS)

    Kim, Hyungtae; Jeong, Choongheui

    2013-01-01

    Verification and Validation (V and V) include the analysis, evaluation, review, inspection, assessment, and testing of products. Especially testing is an important method to verify and validate software. Software V and V testing covers test planning to execution. IEEE Std. 1012 is a standard on the software V and V. Recently, IEEE Std. 1012-2012 was published. This standard is a major revision to IEEE Std. 1012-2004 which defines only software V and V. It expands the scope of the V and V processes to include system and hardware as well as software. This standard describes the scope of V and V testing according to integrity level. In addition, independent V and V requirement related to software V and V testing in IEEE 7-4.3.2-2010 have been revised. This paper provides a recent trend of software V and V testing by reviewing of IEEE Std. 1012-2012 and IEEE 7-4.3.2-2010. There are no major changes of software V and V testing activities and tasks in IEEE 1012-2012 compared with IEEE 1012-2004. But the positions on the responsibility to perform software V and V testing are changed. In addition IEEE 7-4.3.2-2010 newly describes the positions on responsibility to perform Software V and V Testing. However, the positions of these standards on the V and V testing are different. For integrity level 3 and 4, IEEE 1012-2012 basically requires that V and V organization shall conduct all of V and V testing tasks such as test plan, test design, test case, and test procedure except test execution. If V and V testing is conducted by not V and V but another organization, the results of that testing shall be analyzed by the V and V organization. For safety-related software, IEEE 7-4.3.2-2010 requires that test procedures and reports shall be independently verified by the alternate organization regardless of who writes the procedures and/or conducts the tests

  11. Sandia technology. Volume 13, number 2 Special issue: verification of arms control treaties

    International Nuclear Information System (INIS)

    1989-01-01

    Nuclear deterrence, a cornerstone of US national security policy, has helped prevent global conflict for over 40 years. The DOE and DoD share responsibility for this vital part of national security. The US will continue to rely on nuclear deterrence for the foreseeable future. In the late 1950s, Sandia developed satellite-borne nuclear burst detection systems to support the treaty banning atmospheric nuclear tests. This activity has continued to expand and diversify. When the Non-Proliferation Treaty was ratified in 1970, we began to develop technologies to protect nuclear materials from falling into unauthorized hands. This program grew and now includes systems for monitoring the movement and storage of nuclear materials, detecting tampering, and transmiting sensitive data securely. In the late 1970s, negotiations to further limit underground nuclear testing were being actively pursued. In less than 18 months, we fielded the National Seismic Station, an unattended observatory for in-country monitoring of nuclear tests. In the mid-l980s, arms-control interest shifted to facility monitoring and on-site inspection. Our Technical On-site Inspection Facility is the national test bed for perimeter and portal monitoring technology and the prototype for the inspection portal that was recently installed in the USSR under the Intermediate-Range Nuclear Forces accord. The articles in the special issue of Sundiu Technology describe some of our current contributions to verification technology. This work supports the US policy to seek realistic arms control agreements while maintaining our national security.

  12. Sandia technology. Volume 13, number 2 Special issue : verification of arms control treaties.

    Energy Technology Data Exchange (ETDEWEB)

    1989-03-01

    Nuclear deterrence, a cornerstone of US national security policy, has helped prevent global conflict for over 40 years. The DOE and DoD share responsibility for this vital part of national security. The US will continue to rely on nuclear deterrence for the foreseeable future. In the late 1950s, Sandia developed satellite-borne nuclear burst detection systems to support the treaty banning atmospheric nuclear tests. This activity has continued to expand and diversify. When the Non-Proliferation Treaty was ratified in 1970, we began to develop technologies to protect nuclear materials from falling into unauthorized hands. This program grew and now includes systems for monitoring the movement and storage of nuclear materials, detecting tampering, and transmiting sensitive data securely. In the late 1970s, negotiations to further limit underground nuclear testing were being actively pursued. In less than 18 months, we fielded the National Seismic Station, an unattended observatory for in-country monitoring of nuclear tests. In the mid-l980s, arms-control interest shifted to facility monitoring and on-site inspection. Our Technical On-site Inspection Facility is the national test bed for perimeter and portal monitoring technology and the prototype for the inspection portal that was recently installed in the USSR under the Intermediate-Range Nuclear Forces accord. The articles in the special issue of Sundiu Technology describe some of our current contributions to verification technology. This work supports the US policy to seek realistic arms control agreements while maintaining our national security.

  13. Performance Verification of Impact Machines for Testing Plastics

    Science.gov (United States)

    Siewert, T. A.; Vigliotti, D. P.; Dirling, L. B.; McCowan, C. N.

    1999-01-01

    Valid comparison of impact test energies reported by various organizations and over time depends on consistent performance of impact test machines. This paper investigates the influence of various specimen and test parameters on impact energies in the 1 J to 2 J range for both Charpy V-notch and Izod procedures, leading toward the identification of a suitable material for use in a program to verify machine performance. We investigated the influences on the absorbed energy of machine design, test material, specimen cross sectional area, and machine energy range. For comparison to published round robin data on common plastics, this study used some common metallic alloys, including those used in the international verification program for metals impact machines and in informal calibration programs of tensile machines. The alloys that were evaluated include AISI type 4340 steel, and five aluminum alloys: 2014-T6, 2024-T351, 2219-T87, 6061-T6, and 7075-T6. We found that certain metallic alloys have coefficients of variation comparable to those of the best plastics that are reported in the literature. Also, we found that the differences in absorbed energy between two designs of machines are smaller than the differences that can be attributed to the specimens alone.

  14. Expose : procedure and results of the joint experiment verification tests

    Science.gov (United States)

    Panitz, C.; Rettberg, P.; Horneck, G.; Rabbow, E.; Baglioni, P.

    The International Space Station will carry the EXPOSE facility accommodated at the universal workplace URM-D located outside the Russian Service Module. The launch will be affected in 2005 and it is planned to stay in space for 1.5 years. The tray like structure will accomodate 2 chemical and 6 biological PI-experiments or experiment systems of the ROSE (Response of Organisms to Space Environment) consortium. EXPOSE will support long-term in situ studies of microbes in artificial meteorites, as well as of microbial communities from special ecological niches, such as endolithic and evaporitic ecosystems. The either vented or sealed experiment pockets will be covered by an optical filter system to control intensity and spectral range of solar UV irradiation. Control of sun exposure will be achieved by the use of individual shutters. To test the compatibility of the different biological systems and their adaptation to the opportunities and constraints of space conditions a profound ground support program has been developed. The procedure and first results of this joint Experiment Verification Tests (EVT) will be presented. The results will be essential for the success of the EXPOSE mission and have been done in parallel with the development and construction of the final hardware design of the facility. The results of the mission will contribute to the understanding of the organic chemistry processes in space, the biological adaptation strategies to extreme conditions, e.g. on early Earth and Mars, and the distribution of life beyond its planet of origin.

  15. Radio-xenon monitoring technology for CTBT verification

    Energy Technology Data Exchange (ETDEWEB)

    An, J. S.; Yoon, W. K.; Shin, J. S.; Kim, J. S.; Lee, Y. G.; Na, W. W

    1998-03-01

    To help ensure compliance with a comprehensive nuclear test ban treaty (CTBT), it is important that monitoring technologies for detecting covert nuclear testing be available. Monitoring methods are included seismic, hydroacoustic, infra-sound, and radionuclide technologies. Conducting a test underground, underwater, under such condition, gaseous radionuclides detection would be useful method for detecting of nuclear detonation. This report described on as to performance of detecting equipment and detecting principle of radioactive described on as to performance of detecting equipment and detecting principle of radioactive noble gas detection for CTBT. Although the quantity of xenon radionuclides entering the atmosphere from a nuclear detonation may be very large, the combination of dilution in the atmosphere plus radioactive decay requires very sensitive measurements to detect these radionuclides. Furthermore, xenon radionuclides can be enter the atmosphere from sources other than nuclear detonation, including operating nuclear reactors, producing and using medical isotopes and nuclear fuel reprocessing. Since measurement of the activity ratios of xenon radionuclides is important for determine of their origin. (author). 19 refs., 13 tabs., 18 figs

  16. Enhanced verification test suite for physics simulation codes

    Energy Technology Data Exchange (ETDEWEB)

    Kamm, James R.; Brock, Jerry S.; Brandon, Scott T.; Cotrell, David L.; Johnson, Bryan; Knupp, Patrick; Rider, William J.; Trucano, Timothy G.; Weirs, V. Gregory

    2008-09-01

    This document discusses problems with which to augment, in quantity and in quality, the existing tri-laboratory suite of verification problems used by Los Alamos National Laboratory (LANL), Lawrence Livermore National Laboratory (LLNL), and Sandia National Laboratories (SNL). The purpose of verification analysis is demonstrate whether the numerical results of the discretization algorithms in physics and engineering simulation codes provide correct solutions of the corresponding continuum equations.

  17. 76 FR 50164 - Protocol Gas Verification Program and Minimum Competency Requirements for Air Emission Testing...

    Science.gov (United States)

    2011-08-12

    ... in commenting must do so at this time. For further information, please see the information provided...-AQ06 Protocol Gas Verification Program and Minimum Competency Requirements for Air Emission Testing... correct certain portions of the Protocol Gas Verification Program and Minimum Competency Requirements for...

  18. VZLUSAT-1: verification of new materials and technologies for space

    Science.gov (United States)

    Daniel, Vladimir; Urban, Martin; Nentvich, Ondrej; Stehlikova, Veronika

    2016-09-01

    CubeSats are a good opportunity to test new technologies and materials on orbit. These innovations can be later used for improving of properties and life length of Cubesat or other satellites as well. VZLUSAT-1 is a small satellite from the CubeSat family, which will carry a wide scale of payloads with different purposes. The poster is focused on measuring of degradation and properties measurement of new radiation hardened composite material in orbit due to space environment. Material properties changes can be studied by many methods and in many disciplines. One payload measures mechanical changes in dependence on Young's modulus of elasticity which is got from non-destructive testing by mechanical vibrations. The natural frequencies we get using Fast Fourier Transform. The material is tested also by several thermometers which measure heat distribution through the composite, as well as reflectivity in dependence on different coatings. The satellite also will measure the material radiation shielding properties. There are PIN diodes which measure the relative shielding efficiency of composite and how it will change in time in space environment. Last one of material space testing is measurement of outgassing from tested composite material. It could be very dangerous for other parts of satellite, like detectors, when anything was outgassing, for example water steam. There are several humidity sensors which are sensitive to steam and other gases and measures temperatures as well.

  19. Manual and automation testing and verification of TEQ [ECI PROPIRETRY

    Science.gov (United States)

    Abhichandra, Ravi; Jasmine Pemeena Priyadarsini, M.

    2017-11-01

    The telecommunication industry has progressed from 1G to 4G and now 5G is gaining prominence. Given the pace of this abrupt transformation, technological obsolescence is becoming a serious issue to deal with. Adding to this fact is that the execution of each technology requires ample investment into network, infrastructure, development etc. As a result, the industry is becoming more dynamic and strategy oriented. It requires professionals who not only can understand technology but also can evaluate the same from a business perspective. The “Information Revolution” and the dramatic advances in telecommunications technology, which has made this possible, currently drive the global economy in large part. As wireless networks become more advanced and far-reaching, we are redefining the notion of connectivity and the possibilities of communications technology. In this paper I test and verify the optical cards and automate this test procedure by using a new in-house technology “TEQ” developed by ECI TELECOM which uses one the optical cards itself to pump traffic of 100gbps.

  20. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, MIRATECH CORPORATIONM GECO 3001 AIR/FUEL RATIO CONTROLLER

    Science.gov (United States)

    Details on the verification test design, measurement test procedures, and Quality assurance/Quality Control (QA/QC) procedures can be found in the test plan titled Testing and Quality Assurance Plan, MIRATECH Corporation GECO 3100 Air/Fuel Ratio Controller (SRI 2001). It can be d...

  1. Testing Technology: A Sandia technology bulletin

    Energy Technology Data Exchange (ETDEWEB)

    Goetsch, B.; Floyd, H.L.; Doran, L. [eds.

    1994-08-01

    Inside this issue is a farewell to Testing Technology message from technical advisor, Ruth David. Also included are articles on: Testing the I-40 bridge over the Rio Grande, simulated reactor meltdown studies, an inexpensive monitor for testing integrated circuits, testing of antihelicoptor mines, and quality assurance on aircraft inspection.

  2. HVI-Test Setup for Debris Detector Verification

    Science.gov (United States)

    Bauer, Waldemar; Romberg, Oliver; Wiedemann, Carsten; Putzar, Robin; Drolshagen, Gerhard; Vorsmann, Peter

    2013-08-01

    concerning space debris and micrometeoroids. In this way, the SOLID method will allow the generation of a large amount of impact data for environmental model validation. The ground verification of the SOLID method was performed at Fraunhofer EMI. For this purpose, a test model was developed. This paper focuses on the test methodology and development of the Hypervelocity Impact (HVI) test setup, including pretesting at the German Aerospace Centre (DLR), Bremen. Foreseen hardware and software for the automatic damage assessment of the detector after the impact are also presented.

  3. The development of advanced instrumentation and control technology -The development of verification and validation technology for instrumentation and control in NPPs-

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Kee Choon; Ham, Chang Sik; Lee, Byung Sun; Kim, Jung Taek; Park, Won Man; Park, Jae Chang; Lee, Jang Soo; Um, Heung Sub; Kim, Jang Yul; Ryoo, Chan Hoh; Joo, Jae Yoon; Song, Soon Ja [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-07-01

    We collected and analyzed the domestic/international codes, standards and guidelines to develop high reliable software verification and validation methodology which is satisfied to our real situation. The three major parts of work are performed that is the construction of the frame for high reliable software development environment, establishment of high reliable software development methodology and study for the basic technology related to safety-critical software. These three parts are tightly coupled each other to achieve self-reliable software verification and validation technology for digital I and C in NPPs. The configuration of hardware and software are partly performed using requirements which is developed in first stage for the development of I and C test facility. In hardware part, expanded interface using VXI bus and driving software is completed. The main program for math, modelling and supervisor program for instructions are developed. 27 figs, 22 tabs, 69 refs. (Author).

  4. Project W-030 flammable gas verification monitoring test

    International Nuclear Information System (INIS)

    BARKER, S.A.

    1999-01-01

    This document describes the verification monitoring campaign used to document the ability of the new ventilation system to mitigate flammable gas accumulation under steady state tank conditions. This document reports the results of the monitoring campaign. The ventilation system configuration, process data, and data analysis are presented

  5. Quality Assurance in Environmental Technology Verification (ETV): Analysis and Impact on the EU ETV Pilot Programme Performance

    Science.gov (United States)

    Molenda, Michał; Ratman-Kłosińska, Izabela

    2018-03-01

    Many innovative environmental technologies never reach the market because they are new and cannot demonstrate a successful track record of previous applications. This fact is a serious obstacle on their way to the market. Lack of credible data on the performance of a technology causes mistrust of investors in innovations, especially from public sector, who seek effective solutions however without compromising the technical and financial risks associated with their implementation. Environmental technology verification (ETV) offers a credible, robust and transparent process that results in a third party confirmation of the claims made by the providers about the performance of the novel environmental technologies. Verifications of performance are supported by high quality, independent test data. In that way ETV as a tool helps establish vendor credibility and buyer confidence. Several countries across the world have implemented ETV in the form of national or regional programmes. ETV in the European Union was implemented as a voluntary scheme if a form of a pilot programme. The European Commission launched the Environmental Technology Pilot Programme of the European Union (EU ETV) in 2011. The paper describes the European model of ETV set up and put to operation under the Pilot Programme of Environmental Technologies Verification of the European Union. The goal, objectives, technological scope, involved entities are presented. An attempt has been made to summarise the results of the EU ETV scheme performance available for the period of 2012 when the programme has become fully operational until the first half of 2016. The study was aimed at analysing the overall organisation and efficiency of the EU ETV Pilot Programme. The study was based on the analysis of the documents the operation of the EU ETV system. For this purpose, a relevant statistical analysis of the data on the performance of the EU ETV system provided by the European Commission was carried out.

  6. The JPSS Ground Project Algorithm Verification, Test and Evaluation System

    Science.gov (United States)

    Vicente, G. A.; Jain, P.; Chander, G.; Nguyen, V. T.; Dixon, V.

    2016-12-01

    The Government Resource for Algorithm Verification, Independent Test, and Evaluation (GRAVITE) is an operational system that provides services to the Suomi National Polar-orbiting Partnership (S-NPP) Mission. It is also a unique environment for Calibration/Validation (Cal/Val) and Data Quality Assessment (DQA) of the Join Polar Satellite System (JPSS) mission data products. GRAVITE provides a fast and direct access to the data and products created by the Interface Data Processing Segment (IDPS), the NASA/NOAA operational system that converts Raw Data Records (RDR's) generated by sensors on the S-NPP into calibrated geo-located Sensor Data Records (SDR's) and generates Mission Unique Products (MUPS). It also facilitates algorithm investigation, integration, checkouts and tuning, instrument and product calibration and data quality support, monitoring and data/products distribution. GRAVITE is the portal for the latest S-NPP and JPSS baselined Processing Coefficient Tables (PCT's) and Look-Up-Tables (LUT's) and hosts a number DQA offline tools that takes advantage of the proximity to the near-real time data flows. It also contains a set of automated and ad-hoc Cal/Val tools used for algorithm analysis and updates, including an instance of the IDPS called GRAVITE Algorithm Development Area (G-ADA), that has the latest installation of the IDPS algorithms running in an identical software and hardware platforms. Two other important GRAVITE component are the Investigator-led Processing System (IPS) and the Investigator Computing Facility (ICF). The IPS is a dedicated environment where authorized users run automated scripts called Product Generation Executables (PGE's) to support Cal/Val and data quality assurance offline. This data-rich and data-driven service holds its own distribution system and allows operators to retrieve science data products. The ICF is a workspace where users can share computing applications and resources and have full access to libraries and

  7. ENVIORNMENTAL TECHNOLOGY VERIFICATION REPORT: ANEST IWATA CORPORATION LPH400-LV HVLP SPRAY GUN

    Science.gov (United States)

    This Enviornmental Technology Verification reports on the characteristics of a paint spray gun. The research showed that the spray gun provided absolute and relative increases in transfer efficiency over the base line and provided a reduction in the use of paint.

  8. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, BAGHOUSE FILTRATION PRODUCTS, TETRATEC PTFE PRODUCTS, TETRATEX 6212 FILTER SAMPLE

    Science.gov (United States)

    Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) Verification Center. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of the size of those particles equal to and smalle...

  9. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, BAGHOUSE FILTRATION PRODUCTS, BHA GROUP, INC., QP131 FILTER SAMPLE

    Science.gov (United States)

    Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) Verification Center. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of the size of those particles equal to and smalle...

  10. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, BAGHOUSE FILTRATION PRODUCTS, POLYMER GROUP, INC., DURAPEX PET FILTER SAMPLE

    Science.gov (United States)

    Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) Verification Center. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of the size of those particles equal to and smalle...

  11. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT - BAGHOUSE FILTRATION PRODUCTS - W.L. GORE & ASSOCIATES, INC. L4347 FILTER SAMPLE

    Science.gov (United States)

    Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of th...

  12. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT - BAGHOUSE FILTRATION PRODUCTS - BASF CORPORATION AX/BA-14/9-SAXP FILTER SAMPLE

    Science.gov (United States)

    Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of th...

  13. GENERIC VERIFICATION PROTOCOL FOR DETERMINATION OF EMISSIONS REDUCTIONS FROM SELECTIVE CATALYTIC REDUCTIONS CONTROL TECHNOLOGIES FOR HIGHWAY, NONROAD, AND STATIONARY USE DIESEL ENGINES

    Science.gov (United States)

    The protocol describes the Environmental Technology Verification (ETV) Program's considerations and requirements for verification of emissions reduction provided by selective catalytic reduction (SCR) technologies. The basis of the ETV will be comparison of the emissions and perf...

  14. Achievement report on developing superconductor power applied technologies in fiscal 1999 (2). Research and development of superconductor wire materials, research and development of superconductor power generators, research of total systems, research and development of freezing systems, and verification tests; 1999 nendo chodendo denryoku oyo gijutsu kaihatsu seika hokokusho. 2. Chodendo senzai no kenkyu kaihatsu / chodendo hatsudenki no kenkyu kaihatsu / total system no kenkyu / reito system no kenkyu kaihatsu / jissho shiken

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    With an objective to achieve higher efficiency, higher density, and higher stability in power systems, research and development has been performed on superconductor power generators. This paper summarizes the achievements thereof in fiscal 1999. A verification test was given on the rotor of an ultra high speed responding generator. In a sudden short circuit test using the different phase charging method, no anomalies were found such as quench generation and vibration changes, wherein the healthiness of the generator was verified. In the VVVF actuation test, knowledge was acquired on the actuation method when the ultra high speed responding generator is applied to a combined cycle plant. After the verification test has been completed, the disassembly inspections such as visual check and non-destructive test were performed. With regard to the vacuum leakage found in the rotor under very low temperatures, the causes were presumed and the countermeasures were discussed by observing the weld structures. In the design research, the conception design on the 200-MW pilot generator was reviewed by reflecting the results of the verification tests on the model generator. At the same time, trial design was made on a 600-MW target generator. In summarizing the overall research achievements, the achievements and evaluations were summarized on technological issues that have been allotted to each research member. (NEDO)

  15. Update on Monitoring Technologies for International Safeguards and Fissile Material Verification

    International Nuclear Information System (INIS)

    Croessmann, C. Dennis; Glidewell, Don D.; Mangan, Dennis L.; Smathers, Douglas C.

    1999-01-01

    Monitoring technologies are playing an increasingly important part in international safeguards and fissile material verification. The developments reduce the time an inspector must spend at a site while assuring continuity of knowledge. Monitoring technologies' continued development has produced new seal systems and integrated video surveillance advances under consideration for Trilateral Initiative use. This paper will present recent developments for monitoring systems at Embalse, Argentina, VNHEF, Sarov, Russian, and Savannah River Site, Aiken, South Carolina

  16. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, HVLP COATING EQUIPMENT, SHARPE MANUFACTURING COMPANY PLATINUM 2012 HVLP SPRAY GUN

    Science.gov (United States)

    This report presents the results of the verification test of the Sharpe Platinum 2013 high-volume, low-pressure gravity-feed spray gun, hereafter referred to as the Sharpe Platinum, which is designed for use in automotive refinishing. The test coating chosen by Sharpe Manufacturi...

  17. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: DEVILBISS JGHV-531-46FF HVLP SPRAY GUN

    Science.gov (United States)

    This report presents the results of the verification test of the DeVilbiss JGHV-531-46FF high-volume, low-pressure pressure-feed spray gun, hereafter referred to as the DeVilbiss JGHV, which is designed for use in industrial finishing. The test coating chosen by ITW Industrial Fi...

  18. Operational Concept of the NEXTSat-1 for Science Mission and Space Core Technology Verification

    Directory of Open Access Journals (Sweden)

    Goo-Hwan Shin

    2014-03-01

    Full Text Available The next generation small satellite-1 (NEXTSat-1 program has been kicked off in 2012, and it will be launched in 2016 for the science missions and the verification of space core technologies. The payloads for these science missions are the Instrument for the Study of Space Storms (ISSS and NIR Imaging Spectrometer for Star formation history (NISS. The ISSS and the NISS have been developed by Korea Advanced Institute of Science and Technology (KAIST and Korea Astronomy and Space science Institute (KASI respectively. The ISSS detects plasma densities and particle fluxes of 10 MeV energy range near the Earth and the NISS uses spectrometer. In order to verify the spacecraft core technologies in the space, the total of 7 space core technologies (SCT will be applied to the NEXTSat-1 for space verification and those are under development. Thus, the operation modes for the ISSS and the NISS for space science missions and 7 SCTs for technology missions are analyzed for the required operation time during the NEXTSat-1’s mission life time of 2 years. In this paper, the operational concept of the NEXTSat-1’s science missions as well as the verification of space core technologies are presented considering constraints of volume, mass, and power after launch.

  19. Independent Verification Survey Report For Zone 1 Of The East Tennessee Technology Park In Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    King, David A.

    2012-01-01

    Oak Ridge Associated Universities (ORAU) conducted in-process inspections and independent verification (IV) surveys in support of DOE's remedial efforts in Zone 1 of East Tennessee Technology Park (ETTP) in Oak Ridge, Tennessee. Inspections concluded that the remediation contractor's soil removal and survey objectives were satisfied and the dynamic verification strategy (DVS) was implemented as designed. Independent verification (IV) activities included gamma walkover surveys and soil sample collection/analysis over multiple exposure units (EUs)

  20. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT - LEAD IN DUST WIPE MEASUREMENT TECHNOLOGY, PALINTEST, SCANNING ANALYZER , SA-5000 SYSTEM

    Science.gov (United States)

    ETV works in partnership with recognized standards and testing organizations and stakeholder groups consisting of regulators, buyers, and vendor organizations, with the full participation of individual technology developers. The program evaluates the performance of innovative

  1. Developing Reading and Listening Comprehension Tests Based on the Sentence Verification Technique (SVT).

    Science.gov (United States)

    Royer, James M.

    2001-01-01

    Describes a team-based approach for creating Sentence Verification Technique (SVT) tests, a development procedure that allows teachers and other school personnel to develop comprehension tests from curriculum materials in use in their schools. Finds that if tests are based on materials that are appropriate for the population to be tested, the…

  2. Integrating software testing and run-time checking in an assertion verification framework

    OpenAIRE

    Mera, E.; López García, Pedro; Hermenegildo, Manuel V.

    2009-01-01

    We have designed and implemented a framework that unifies unit testing and run-time verification (as well as static verification and static debugging). A key contribution of our approach is that a unified assertion language is used for all of these tasks. We first propose methods for compiling runtime checks for (parts of) assertions which cannot be verified at compile-time via program transformation. This transformation allows checking preconditions and postconditions, including conditional...

  3. Warm Water Oxidation Verification - Scoping and Stirred Reactor Tests

    Energy Technology Data Exchange (ETDEWEB)

    Braley, Jenifer C.; Sinkov, Sergey I.; Delegard, Calvin H.; Schmidt, Andrew J.

    2011-06-15

    Scoping tests to evaluate the effects of agitation and pH adjustment on simulant sludge agglomeration and uranium metal oxidation at {approx}95 C were performed under Test Instructions(a,b) and as per sections 5.1 and 5.2 of this Test Plan prepared by AREVA. (c) The thermal testing occurred during the week of October 4-9, 2010. The results are reported here. For this testing, two uranium-containing simulant sludge types were evaluated: (1) a full uranium-containing K West (KW) container sludge simulant consisting of nine predominant sludge components; (2) a 50:50 uranium-mole basis mixture of uraninite [U(IV)] and metaschoepite [U(VI)]. This scoping study was conducted in support of the Sludge Treatment Project (STP) Phase 2 technology evaluation for the treatment and packaging of K-Basin sludge. The STP is managed by CH2M Hill Plateau Remediation Company (CHPRC) for the U.S. Department of Energy. Warm water ({approx}95 C) oxidation of sludge, followed by immobilization, has been proposed by AREVA and is one of the alternative flowsheets being considered to convert uranium metal to UO{sub 2} and eliminate H{sub 2} generation during final sludge disposition. Preliminary assessments of warm water oxidation have been conducted, and several issues have been identified that can best be evaluated through laboratory testing. The scoping evaluation documented here was specifically focused on the issue of the potential formation of high strength sludge agglomerates at the proposed 95 C process operating temperature. Prior hydrothermal tests conducted at 185 C produced significant physiochemical changes to genuine sludge, including the formation of monolithic concretions/agglomerates that exhibited shear strengths in excess of 100 kPa (Delegard et al. 2007).

  4. Development of a test system for verification and validation of nuclear transport simulations

    Energy Technology Data Exchange (ETDEWEB)

    White, Morgan C [Los Alamos National Laboratory; Triplett, Brian S [GENERAL ELECTRIC; Anghaie, Samim [UNIV OF FL

    2008-01-01

    Verification and validation of nuclear data is critical to the accuracy of both stochastic and deterministic particle transport codes. In order to effectively test a set of nuclear data, the data must be applied to a wide variety of transport problems. Performing this task in a timely, efficient manner is tedious. The nuclear data team at Los Alamos National laboratory in collaboration with the University of Florida has developed a methodology to automate the process of nuclear data verification and validation (V and V). This automated V and V process can efficiently test a number of data libraries using well defined benchmark experiments, such as those in the International Criticality Safety Benchmark Experiment Project (ICSBEP). The process is implemented through an integrated set of Pyton scripts. Material and geometry data are read from an existing medium or given directly by the user to generate a benchmark experiment template file. The user specifies the choice of benchmark templates, codes, and libraries to form a V and V project. The Python scripts generate input decks for multiple transport codes from the templates, run and monitor individual jobs, and parse the relevant output automatically. The output can then be used to generate reports directly or can be stored into a database for later analysis. This methodology eases the burden on the user by reducing the amount of time and effort required for obtaining and compiling calculation results. The resource savings by using this automated methodology could potentially be an enabling technology for more sophisticated data studies, such as nuclear data uncertainty quantification. Once deployed, this tool will allow the nuclear data community to more thoroughly test data libraries leading to higher fidelity data in the future.

  5. Development of a test suite for nuclear data verification and validation

    International Nuclear Information System (INIS)

    Triplett, Brian; Anghaie, Samim; White, Morgan

    2008-01-01

    Verification and validation of nuclear data is critical to the accuracy of both stochastic and deterministic particle transport codes. In order to effectively test a set of nuclear data, the data must be applied to a wide variety of transport problems. Performing this task in a timely, efficient manner is tedious. The nuclear data team at Los Alamos National Laboratory in collaboration with the University of Florida has developed a methodology to automate the process of nuclear data verification and validation (V and V). This automated V and V process can efficiently test a number of data libraries using well defined benchmark experiments, such as those in the International Criticality Safety Benchmark Experiment Project (ICSBEP). The process is implemented through an integrated set of Python scripts. Material and geometry data are read from an existing medium or given directly by the user to generate a benchmark experiment template file. The user specifies the choice of benchmark templates, codes, and libraries to form a V and V project. The Python scripts generate input decks for multiple transport codes from the templates, run and monitor individual jobs, and parse the relevant output automatically. The output can then be used to generate reports directly or can be stored into a database for later analysis. This methodology eases the burden on the user by reducing the amount of time and effort required for obtaining and compiling calculation results. The resource savings by using this automated methodology could potentially be an enabling technology for more sophisticated data studies, such as nuclear data uncertainty quantification. Once deployed, this tool will allow the nuclear data community to more thoroughly test data libraries leading to higher fidelity data in the future. (authors)

  6. Field test plan: Buried waste technologies, Fiscal Year 1995

    International Nuclear Information System (INIS)

    Heard, R.E.; Hyde, R.A.; Engleman, V.S.; Evans, J.D.; Jackson, T.W.

    1995-06-01

    The US Department of Energy, Office of Technology Development, supports the applied research, development, demonstration, testing, and evaluation of a suite of advanced technologies that, when integrated with commercially available baseline technologies, form a comprehensive remediation system for the effective and efficient remediation of buried waste. The Fiscal Year 1995 effort is to deploy and test multiple technologies from four functional areas of buried waste remediation: site characterization, waste characterization, retrieval, and treatment. This document is the basic operational planning document for the deployment and testing of the technologies that support the field testing in Fiscal Year 1995. Discussed in this document are the scope of the tests; purpose and objective of the tests; organization and responsibilities; contingency plans; sequence of activities; sampling and data collection; document control; analytical methods; data reduction, validation, and verification; quality assurance; equipment and instruments; facilities and utilities; health and safety; residuals management; and regulatory management

  7. Test/QA plan for the verification testing of alternative or reformulated liquid fuels, fuel additives, fuel emulsions, and lubricants for highway and nonroad use heavy-duty diesel engines

    Science.gov (United States)

    This Environmental Technology Verification Program test/QA plan for heavy-duty diesel engine testing at the Southwest Research Institute’s Department of Emissions Research describes how the Federal Test Procedure (FTP), as listed in 40 CFR Part 86 for highway engines and 40 CFR P...

  8. Report on results for fiscal 1997 on development of superconducting electric power application technology. Pt. 2. R and D of superconducting wire, R and D of superconducting generator, studies on total system, R and D of refrigeration system, and verification test; 1997 nendo chodendo denryoku oyo gijutsu kaihatsu seika hokokusho. Chodendo senzai no kenkyu kaihatsu, chodendo hatsudenki no kenkyu kaihatsu, total system no kenkyu, reito system no kenkyu kaihatsu, jissho shiken

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-09-01

    This report refers, continuously to the Part 1, to the in-situ verification test of the slow-response type model machine rotor and to the review of the conceptual design of the pilot machine. On the basis of the R and D results of various element technology/partial models obtained before the previous fiscal year, the design, manufacturing and factory test had been conducted for a 70,000kW class slow-response type model machine rotor. This year, an in-situ verification test was performed to complete the test of all planned test items. Using the technological results obtained in the design, manufacturing and test of the 70,000kW class model machine, the conceptual design is being reviewed of the 200,000kW class pilot machine. In the aspect of the functional design, accurate grasping of the thermal load is essential for the purpose of attaining a large capacity for a superconducting generator, as a part of which a thermal load analytical method was planned to be established for a torque tube heat exchanger. The reasonableness of the analysis was verified through a comparison with the factory test result of the 70,000kW class slow-response type rotor, indicating good agreement between the calculation result and the actual measurement, and enabling the result to be obtained that explains dependency of the thermal load on the number of revolution. (NEDO)

  9. RAPID FREEFORM SHEET METAL FORMING: TECHNOLOGY DEVELOPMENT AND SYSTEM VERIFICATION

    Energy Technology Data Exchange (ETDEWEB)

    Kiridena, Vijitha [Ford Scientific Research Lab., Dearborn, MI (United States); Verma, Ravi [Boeing Research and Technology (BR& T), Seattle, WA (United States); Gutowski, Timothy [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Roth, John [Pennsylvania State Univ., University Park, PA (United States)

    2018-03-31

    The objective of this project is to develop a transformational RApid Freeform sheet metal Forming Technology (RAFFT) in an industrial environment, which has the potential to increase manufacturing energy efficiency up to ten times, at a fraction of the cost of conventional technologies. The RAFFT technology is a flexible and energy-efficient process that eliminates the need for having geometry-specific forming dies. The innovation lies in the idea of using the energy resource at the local deformation area which provides greater formability, process control, and process flexibility relative to traditional methods. Double-Sided Incremental Forming (DSIF), the core technology in RAFFT, is a new concept for sheet metal forming. A blank sheet is clamped around its periphery and gradually deformed into a complex 3D freeform part by two strategically aligned stylus-type tools that follow a pre-described toolpath. The two tools, one on each side of the blank, can form a part with sharp features for both concave and convex shapes. Since deformation happens locally, the forming force at any instant is significantly decreased when compared to traditional methods. The key advantages of DSIF are its high process flexibility, high energy-efficiency, low capital investment, and the elimination of the need for massive amounts of die casting and machining. Additionally, the enhanced formability and process flexibility of DSIF can open up design spaces and result in greater weight savings.

  10. Stirling cryocooler test results and design model verification

    International Nuclear Information System (INIS)

    Shimko, M.A.; Stacy, W.D.; McCormick, J.A.

    1990-01-01

    This paper reports on progress in developing a long-life Stirling cycle cryocooler for space borne applications. It presents the results from tests on a preliminary breadboard version of the cryocooler used to demonstrate the feasibility of the technology and to validate the regenerator design code used in its development. This machine achieved a cold-end temperature of 65 K while carrying a 1/2 Watt cooling load. The basic machine is a double-acting, flexure-bearing, split Stirling design with linear electromagnetic drives for the expander and compressors. Flat metal diaphragms replace pistons for both sweeping and sealing the machine working volumes. In addition, the double-acting expander couples to a laminar-channel counterflow recuperative heat exchanger for regeneration. A PC compatible design code was developed for this design approach that calculates regenerator loss including heat transfer irreversibilities, pressure drop, and axial conduction in the regenerator walls

  11. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: IN-DRAIN TREATMENT DEVICE. HYDRO INTERNATIONAL UP-FLO™ FILTER

    Science.gov (United States)

    Verification testing of the Hydro International Up-Flo™ Filter with one filter module and CPZ Mix™ filter media was conducted at the Penn State Harrisburg Environmental Engineering Laboratory in Middletown, Pennsylvania. The Up-Flo™ Filter is designed as a passive, modular filtr...

  12. An overview of CTBT verification technologies and status of IMS networks

    International Nuclear Information System (INIS)

    Basham, P.

    2002-01-01

    The CTBT history is described in brief. Nuclear test environments and verification regime are presented with illustrations. Geographical location of seismic, hydroacoustic, infrasound and radionuclide monitoring networks are indicated on globe maps. Benefits of the International Monitoring System (IMS) to host countries are listed

  13. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: STORMWATER SOURCE AREA TREATMENT DEVICE — BAYSAVER TECHNOLOGIES, INC. BAYSAVER SEPARATION SYSTEM, MODEL 10K

    Science.gov (United States)

    Verification testing of the BaySaver Separation System, Model 10K was conducted on a 10 acre drainage basin near downtown Griffin, Georgia. The system consists of two water tight pre-cast concrete manholes and a high-density polyethylene BaySaver Separator Unit. The BaySaver Mod...

  14. Verification and Uncertainty Reduction of Amchitka Underground Nuclear Testing Models

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed Hassan; Jenny Chapman

    2006-02-01

    The modeling of Amchitka underground nuclear tests conducted in 2002 is verified and uncertainty in model input parameters, as well as predictions, has been reduced using newly collected data obtained by the summer 2004 field expedition of CRESP. Newly collected data that pertain to the groundwater model include magnetotelluric (MT) surveys conducted on the island to determine the subsurface salinity and porosity structure of the subsurface, and bathymetric surveys to determine the bathymetric maps of the areas offshore from the Long Shot and Cannikin Sites. Analysis and interpretation of the MT data yielded information on the location of the transition zone, and porosity profiles showing porosity values decaying with depth. These new data sets are used to verify the original model in terms of model parameters, model structure, and model output verification. In addition, by using the new data along with the existing data (chemistry and head data), the uncertainty in model input and output is decreased by conditioning on all the available data. A Markov Chain Monte Carlo (MCMC) approach is adapted for developing new input parameter distributions conditioned on prior knowledge and new data. The MCMC approach is a form of Bayesian conditioning that is constructed in such a way that it produces samples of the model parameters that eventually converge to a stationary posterior distribution. The Bayesian MCMC approach enhances probabilistic assessment. Instead of simply propagating uncertainty forward from input parameters into model predictions (i.e., traditional Monte Carlo approach), MCMC propagates uncertainty backward from data onto parameters, and then forward from parameters into predictions. Comparisons between new data and the original model, and conditioning on all available data using MCMC method, yield the following results and conclusions: (1) Model structure is verified at Long Shot and Cannikin where the high-resolution bathymetric data collected by CRESP

  15. Software Verification and Validation Test Report for the HEPA filter Differential Pressure Fan Interlock System

    International Nuclear Information System (INIS)

    ERMI, A.M.

    2000-01-01

    The HEPA Filter Differential Pressure Fan Interlock System PLC ladder logic software was tested using a Software Verification and Validation (VandV) Test Plan as required by the ''Computer Software Quality Assurance Requirements''. The purpose of his document is to report on the results of the software qualification

  16. Achievement report on developing superconductor power applied technologies in fiscal 1999 (1). Research and development of superconductor wire materials, research and development of superconductor power generators, research of total systems, research and development of freezing systems, and verification tests; 1999 nendo chodendo denryoku oyo gijutsu kaihatsu seika hokokusho. 1. Chodendo senzai no kenkyu kaihatsu / chodendo hatsudenki no kenkyu kaihatsu / total system no kenkyu / reito system no kenkyu kaihatsu / jissho shiken

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    With an objective to achieve higher efficiency, higher density, and higher stability in power systems, research and development has been performed on superconductor power applied technologies. This paper summarizes the achievements thereof in fiscal 1999. In research and development of the superconductor wire materials, decrease in loss and increase in capacity of the conductors were progressed for the Nb{sub 3}Sn wire material, whereas its mechanical properties and stability were evaluated. In research and development of the superconductor generators, an ultra high speed responding generator was verified of its healthiness in a sudden short circuit test. A linkage test with an operating 77-kV system was performed, wherein verification was given that the superconductor generator can be operated stably against various disturbances. In research and development of the freezing systems, an improved system was structured, which achieved operation of 11,390 hours in a single system as a result of the high reliability of the oil-free structure. In the verification tests, the ultra high speed responding model generator was connect to the freezing system to give such tests as load test, onerous test, actuation test by using the M-G system, and 77-kV system linkage test. The functions, reliability, and durability of the system were verified, and different data were acquired. (NEDO)

  17. Standard practice for verification of constant amplitude dynamic forces in an axial fatigue testing system

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This practice covers procedures for the dynamic verification of cyclic force amplitude control or measurement accuracy during constant amplitude testing in an axial fatigue testing system. It is based on the premise that force verification can be done with the use of a strain gaged elastic element. Use of this practice gives assurance that the accuracies of forces applied by the machine or dynamic force readings from the test machine, at the time of the test, after any user applied correction factors, fall within the limits recommended in Section 9. It does not address static accuracy which must first be addressed using Practices E 4 or equivalent. 1.2 Verification is specific to a particular test machine configuration and specimen. This standard is recommended to be used for each configuration of testing machine and specimen. Where dynamic correction factors are to be applied to test machine force readings in order to meet the accuracy recommended in Section 9, the verification is also specific to the c...

  18. New Approaches and New Technologies for the Verification of Nuclear Disarmament

    International Nuclear Information System (INIS)

    Keir, David

    2013-01-01

    ESARDA’s New Approaches/Novel Technologies Working group has recently begun to take a great interest in technology for use in arms control verification, in parallel with a focus on Nuclear Safeguards technology. A topic-based meeting of members of the NA/NT Subgroup was hosted at Joint Research Centre (JRC), ITU-Nuclear Security Unit in Ispra (Italy), to further explore the technical issues and opportunities presented by the need for new approaches and technologies in a future verified nuclear weapons dismantlement regime. Nuclear warheads must contain radioactive material and, by their nature, gamma rays and neutrons are likely to penetrate to the outside of the warhead casing and even metal containers. Therefore radiation signatures should be detectable by appropriate pieces of equipment. For this reason, researchers in the field of technical verification of nuclear warhead dismantlement have studied and developed technologies for Non-Destructive Assay (NDA). This paper presents a generic dismantlement pathway for verified nuclear warhead dismantlement, based on the scenario employed by the UK-Norway initiative for their exercise in 2008/9. Using this as a framework the types of measurement challenge likely to be presented to a verifying inspector are discussed. The problem of intrusiveness of measurements in relation to the issue of proliferative release of classified information about the warhead attributes is discussed and the concept of ‘information barriers is introduced as a possible solution to this issue. A list of candidate technologies for use in verification activities, with or without information barriers is then presented and, since most of these are new or novel approaches to the issue, an already-established system for classifying them – in terms of state of development and complexity of use in this context – is proposed. Finally, the concept of capturing this information as a library of ‘data sheets’, designed for periodic review as

  19. Technology of pile dynamic testing

    OpenAIRE

    Holeyman, Alain; The 4th International Conference on the Application of Stress-Wave Theory to Piles

    1992-01-01

    Because of the recent larger availability and higher performance of pile testing and monitoring equipment, pile dynamic testing has become part of many present day civil engineering projects. This report covers the past and state-of-the-art technological aspects of pile dynamic testing: testing methods, loading equipment, and measurements, including their acquisition and interpretation. Three major pile dynamic testing methods are distinguished based on means and objectives: high-strain testi...

  20. Use of Radio Frequency Identification (RFID) for Tracking Hazardous Waste Shipments Across International Borders -Test/QA Plan

    Science.gov (United States)

    The Environmental Technology Verification (ETV) – Environmental and Sustainable Technology Evaluations (ESTE) Program conducts third-party verification testing of commercially available technologies that may accomplish environmental program management goals. In this verification...

  1. Status and Application of Spatial Information Technology as a Nuclear Verification Tool

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Seong Youn; Shin, Jang Soo [Korea Institute of Nuclear Non-proliferation And Control, Daejeon (Korea, Republic of)

    2010-05-15

    The spatial information like satellite imagery and GIS data has been widely used for site development planning and monitoring in the area where the access is not allowed with any reason. The IAEA adopts this new method of analysis for enhancing its verification capability and is utilizing to search if there is any undeclared nuclear activities in the nuclear facilities worldwide. The ROK entered the group of the leading countries in the field of space technology with the successful launching of the KompSat I and II, and holds its high position in the IT technology which can draw useful analytic results from the satellite imagery. It implies that the ROK has some potential and related infra required for using the satellite imagery for the purpose of nuclear safeguards. However, we are in the very early stage to apply these advanced techniques to nuclear verification, because we don't have enough work forces enough to deal with these useful tools. It is necessary to review some previous examples about establishing satellite imagery analysis system like the IAEA. In this report, the IAEA's activities related verification using satellite imagery is reviewed and some examples on safeguards application is presented. A way to use satellite images for national inspection also is suggested

  2. Design verification of the CANFLEX fuel bundle - quality assurance requirements for mechanical flow testing

    International Nuclear Information System (INIS)

    Alavi, P.; Oldaker, I.E.; Chung, C.H.; Suk, H.C.

    1997-01-01

    As part of the design verification program for the new fuel bundle, a series of out-reactor tests was conducted on the CANFLEX 43-element fuel bundle design. These tests simulated current CANDU 6 reactor normal operating conditions of flow, temperature and pressure. This paper describes the Quality Assurance (QA) Program implemented for the tests that were run at the testing laboratories of Atomic Energy of Canada Limited (AECL) and Korea Atomic energy Research Institute (KAERI). (author)

  3. Spyder: Critical Technology Demonstration Tests

    Data.gov (United States)

    National Aeronautics and Space Administration — Two technology demonstrations:Task 1 – Sub-orbital hot fire staging with guidance and control utilizing NASA-Ames AVA. Task 2 – Spyder stage 1 static test, nose...

  4. Working Group 2: Future Directions for Safeguards and Verification, Technology, Research and Development

    International Nuclear Information System (INIS)

    Zykov, S.; Blair, D.

    2013-01-01

    For traditional safeguards it was recognized that the hardware presently available is, in general, addressing adequately fundamental IAEA needs, and that further developments should therefore focus mainly on improving efficiencies (i.e. increasing cost economies, reliability, maintainability and user-friendliness, keeping abreast of continual advancements in technologies and of the evolution of verification approaches). Specific technology areas that could benefit from further development include: -) Non-destructive measurement systems (NDA), in particular, gamma-spectroscopy and neutron counting techniques; -) Containment and surveillance tools, such as tamper indicating seals, video-surveillance, surface identification methods, etc.; -) Geophysical methods for design information verification (DIV) and safeguarding of geological repositories; and -) New tools and methods for real-time monitoring. Furthermore, the Working Group acknowledged that a 'building block' (or modular) approach should be adopted towards technology development, enabling equipment to be upgraded efficiently as technologies advance. Concerning non-traditional safeguards, in the area of satellite-based sensors, increased spatial resolution and broadened spectral range were identified as priorities. In the area of wide area surveillance, the development of LIDAR-like tools for atmospheric sensing was discussed from the perspective of both potential benefits and certain limitations. Recognizing the limitations imposed by the human brain in terms of information assessment and analysis, technologies are needed that will enable the more effective utilization of all information, regardless of its format and origin. The paper is followed by the slides of the presentation. (A.C.)

  5. Report on results for fiscal 1997 on development of superconducting electric power application technology. Pt. 1. R and D of superconducting wire, R and D of superconducting generator, studies on total system, R and D of refrigeration system, and verification test; 1997 nendo chodendo denryoku oyo gijutsu kaihatsu seika hokokusho. 1. Chodendo senzai no kenkyu kaihatsu, chodendo hatsudenki no kenkyu kaihatsu, total system no kenkyu, reito system no kenkyu kaihatsu, jissho shiken

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-09-01

    This report explains the outline as Part 1. In fiscal 1997, the 10th year of the project, a multi cylindrical rotary model for which an in-situ verification test was finished was brought back to the plant and dismantled for examination, while the in-situ verification test of a slow-response type model machine rotor was conducted in combination with a refrigeration system. In addition, in the research of AC wire materials and oxide based materials, studies were made with a purpose of high characterization and long wire materialization. In the metallic materials, a 10kANbTi conductor was developed while, in oxide-based materials, research was done on performance improvement and wire materialization based on various synthesizing methods. The manufacturing, factory test and in-situ text were conducted for a 70,000kW model machine with the purpose of R and D of a 200,000kW class pilot machine. Examination was made on the test method of the 70,000kW class model machine, operation technology of a superconducting generation system, and the effect of introducing the superconducting generator into a power system. In the conventional refrigeration system, a single unit test was carried out for the liquefaction, liquid storing capacity, etc., of the system. The 70,000kW class model machine was put through a test for confirming the general operation including the refrigeration system. (NEDO)

  6. Analysis, Test and Verification in The Presence of Variability (Dagstuhl Seminar 13091)

    DEFF Research Database (Denmark)

    2014-01-01

    This report documents the program and the outcomes of Dagstuhl Seminar 13091 “Analysis, Test and Verification in The Presence of Variability”. The seminar had the goal of consolidating and stimulating research on analysis of software models with variability, enabling the design of variability-awa...

  7. 9 CFR 381.94 - Contamination with Microorganisms; process control verification criteria and testing; pathogen...

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Contamination with Microorganisms... § 381.94 Contamination with Microorganisms; process control verification criteria and testing; pathogen... maintaining process controls sufficient to prevent fecal contamination. FSIS shall take further action as...

  8. Development and verification of a reciprocating test rig designed for investigation of piston ring tribology

    DEFF Research Database (Denmark)

    Pedersen, Michael Torben; Imran, Tajammal; Klit, Peder

    2009-01-01

    This paper describes the development and verification of a reciprocating test rig, which was designed to study the piston ring tribology. A crank mechanism is used to generate a reciprocating motion for a moving plate, which acts as the liner. A stationary block acting as the ring package is loaded......, which is suitable for the study of piston ring tribology....

  9. General-Purpose Heat Source Safety Verification Test program: Edge-on flyer plate tests

    International Nuclear Information System (INIS)

    George, T.G.

    1987-03-01

    The radioisotope thermoelectric generator (RTG) that will supply power for the Galileo and Ulysses space missions contains 18 General-Purpose Heat Source (GPHS) modules. The GPHS modules provide power by transmitting the heat of 238 Pu α-decay to an array of thermoelectric elements. Each module contains four 238 PuO 2 -fueled clads and generates 250 W(t). Because the possibility of a launch vehicle explosion always exists, and because such an explosion could generate a field of high-energy fragments, the fueled clads within each GPHS module must survive fragment impact. The edge-on flyer plate tests were included in the Safety Verification Test series to provide information on the module/clad response to the impact of high-energy plate fragments. The test results indicate that the edge-on impact of a 3.2-mm-thick, aluminum-alloy (2219-T87) plate traveling at 915 m/s causes the complete release of fuel from capsules contained within a bare GPHS module, and that the threshold velocity sufficient to cause the breach of a bare, simulant-fueled clad impacted by a 3.5-mm-thick, aluminum-alloy (5052-T0) plate is approximately 140 m/s

  10. General-Purpose Heat Source development: Safety Verification Test Program. Bullet/fragment test series

    Energy Technology Data Exchange (ETDEWEB)

    George, T.G.; Tate, R.E.; Axler, K.M.

    1985-05-01

    The radioisotope thermoelectric generator (RTG) that will provide power for space missions contains 18 General-Purpose Heat Source (GPHS) modules. Each module contains four /sup 238/PuO/sub 2/-fueled clads and generates 250 W/sub (t)/. Because a launch-pad or post-launch explosion is always possible, we need to determine the ability of GPHS fueled clads within a module to survive fragment impact. The bullet/fragment test series, part of the Safety Verification Test Plan, was designed to provide information on clad response to impact by a compact, high-energy, aluminum-alloy fragment and to establish a threshold value of fragment energy required to breach the iridium cladding. Test results show that a velocity of 555 m/s (1820 ft/s) with an 18-g bullet is at or near the threshold value of fragment velocity that will cause a clad breach. Results also show that an exothermic Ir/Al reaction occurs if aluminum and hot iridium are in contact, a contact that is possible and most damaging to the clad within a narrow velocity range. The observed reactions between the iridium and the aluminum were studied in the laboratory and are reported in the Appendix.

  11. General-Purpose Heat Source Safety Verification Test Program: Edge-on flyer plate tests

    Science.gov (United States)

    George, T. G.

    1987-03-01

    The radioisotope thermoelectric generator (RTG) that will supply power for the Galileo and Ulysses space missions contains 18 General-Purpose Heat Source (GPHS) modules. The GPHS modules provide power by transmitting the heat of Pu-238 alpha-decay to an array of thermoelectric elements. Each module contains four Pu-238O2-fueled clads and generates 250 W(t). Because the possibility of a launch vehicle explosion always exists, and because such an explosion could generate a field of high-energy fragments, the fueled clads within each GPHS module must survive fragment impact. The edge-on flyer plate tests were included in the Safety Verification Test series to provide information on the module/clad response to the impact of high-energy plate fragments. The test results indicate that the edge-on impact of a 3.2-mm-thick, aluminum-alloy (2219-T87) plate traveling at 915 m/s causes the complete release of fuel from capsules contained within a bare GPHS module, and that the threshold velocity sufficient to cause the breach of a bare, simulant-fueled clad impacted by a 3.5-mm-thick, aluminum-alloy (5052-TO) plate is approximately 140 m/s.

  12. General-Purpose Heat Source Safety Verification Test program: Edge-on flyer plate tests

    Energy Technology Data Exchange (ETDEWEB)

    George, T.G.

    1987-03-01

    The radioisotope thermoelectric generator (RTG) that will supply power for the Galileo and Ulysses space missions contains 18 General-Purpose Heat Source (GPHS) modules. The GPHS modules provide power by transmitting the heat of STYPu -decay to an array of thermoelectric elements. Each module contains four STYPuO2-fueled clads and generates 250 W(t). Because the possibility of a launch vehicle explosion always exists, and because such an explosion could generate a field of high-energy fragments, the fueled clads within each GPHS module must survive fragment impact. The edge-on flyer plate tests were included in the Safety Verification Test series to provide information on the module/clad response to the impact of high-energy plate fragments. The test results indicate that the edge-on impact of a 3.2-mm-thick, aluminum-alloy (2219-T87) plate traveling at 915 m/s causes the complete release of fuel from capsules contained within a bare GPHS module, and that the threshold velocity sufficient to cause the breach of a bare, simulant-fueled clad impacted by a 3.5-mm-thick, aluminum-alloy (5052-T0) plate is approximately 140 m/s.

  13. Explosion overpressure test series: General-Purpose Heat Source development: Safety Verification Test program

    International Nuclear Information System (INIS)

    Cull, T.A.; George, T.G.; Pavone, D.

    1986-09-01

    The General-Purpose Heat Source (GPHS) is a modular, radioisotope heat source that will be used in radioisotope thermoelectric generators (RTGs) to supply electric power for space missions. The first two uses will be the NASA Galileo and the ESA Ulysses missions. The RTG for these missions will contain 18 GPHS modules, each of which contains four 238 PuO 2 -fueled clads and generates 250 W/sub (t)/. A series of Safety Verification Tests (SVTs) was conducted to assess the ability of the GPHS modules to contain the plutonia in accident environments. Because a launch pad or postlaunch explosion of the Space Transportation System vehicle (space shuttle) is a conceivable accident, the SVT plan included a series of tests that simulated the overpressure exposure the RTG and GPHS modules could experience in such an event. Results of these tests, in which we used depleted UO 2 as a fuel simulant, suggest that exposure to overpressures as high as 15.2 MPa (2200 psi), without subsequent impact, does not result in a release of fuel

  14. HDTS 2017.1 Testing and Verification Document

    Energy Technology Data Exchange (ETDEWEB)

    Whiteside, T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-12-01

    This report is a continuation of the series of Hunter Dose Tracking System (HDTS) Quality Assurance documents including (Foley and Powell, 2010; Dixon, 2012; Whiteside, 2017b). In this report we have created a suite of automated test cases and a system to analyze the results of those tests as well as documented the methodology to ensure the field system performs within specifications. The software test cases cover all of the functions and interactions of functions that are practical to test. With the developed framework, if software defects are discovered, it will be easy to create one or more test cases to reproduce the defect and ensure that code changes correct the defect.

  15. RELAP5-3D Restart and Backup Verification Testing

    Energy Technology Data Exchange (ETDEWEB)

    Mesina, George L. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2013-09-01

    Existing testing methodology for RELAP5-3D employs a set of test cases collected over two decades to test a variety of code features and run on a Linux or Windows platform. However, this set has numerous deficiencies in terms of code coverage, detail of comparison, running time, and testing fidelity of RELAP5-3D restart and backup capabilities. The test suite covers less than three quarters of the lines of code in the relap directory and just over half those in the environmental library. Even in terms of code features, many are not covered. Moreover, the test set runs many problems long past the point necessary to test the relevant features. It requires standard problems to run to completion. This is unnecessary for features can be tested in a short-running problem. For example, many trips and controls can be tested in the first few time steps, as can a number of fluid flow options. The testing system is also inaccurate. For the past decade, the diffem script has been the primary tool for checking that printouts from two different RELAP5-3D executables agree. This tool compares two output files to verify that all characters are the same except for those relating to date, time and a few other excluded items. The variable values printed on the output file are accurate to no more than eight decimal places. Therefore, calculations with errors in decimal places beyond those printed remain undetected. Finally, fidelity of restart is not tested except in the PVM sub-suite and backup is not specifically tested at all. When a restart is made from any midway point of the base-case transient, the restart must produce the same values. When a backup condition occurs, the code repeats advancements with the same time step. A perfect backup can be tested by forcing RELAP5 to perform a backup by falsely setting a backup condition flag at a user-specified-time. Comparison of the calculations of that run and those produced by the same input w/o the spurious condition should be

  16. Verification methods for treaties limiting and banning nuclear tests

    International Nuclear Information System (INIS)

    Voloshin, N.P.

    1998-01-01

    Treaty on limitation of underground nuclear weapon tests and treaty on world banning of nuclear tests contribute to and accompany the process of nuclear disarmament. Test ban in three (Moscow treaty of 1963) as well as the Threshold Test Ban up to 1991 was controlled only with national means. But since 1991 nuclear test threshold of 150 kt has been measured with hydrodynamic and tele seismic methods and checked by the inspection. Distinctive feature of this control is that control is that it is bilateral. This conforms to Treaty on limitation of underground nuclear weapon tests signed by two countries - USA and USSR. The inspection at the place of tests requires monitoring of the test site of the party conducting a test and geological information of rock in the area of explosion. In the treaty of the World Nuclear Test Ban the following ways of international control are provided for: - seismologic measurements; - radionuclide measurements; - hydro-acoustics measurements; - infra-sound measurements; - inspection at the place of the tests conduction

  17. ENVIRONMENTAL TECHNOLOGY VERIFICATION: JOINT (NSF-EPA) VERIFICATION STATEMENT AND REPORT: BROME AGRI SALES, LTD., MAXIMIZER SEPARATOR, MODEL MAX 1016 - 03/01/WQPC-SWP

    Science.gov (United States)

    Verification testing of the Brome Agri Sales Ltd. Maximizer Separator, Model MAX 1016 (Maximizer) was conducted at the Lake Wheeler Road Field Laboratory Swine Educational Unit in Raleigh, North Carolina. The Maximizer is an inclined screen solids separator that can be used to s...

  18. HDTS 2017.0 Testing and verification document

    Energy Technology Data Exchange (ETDEWEB)

    Whiteside, Tad S. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-08-01

    This report is a continuation of the series of Hunter Dose Tracking System (HDTS) Quality Assurance documents including (Foley and Powell, 2010; Dixon, 2012). In this report we have created a suite of automated test cases and a system to analyze the results of those tests as well as documented the methodology to ensure the field system performs within specifications. The software test cases cover all of the functions and interactions of functions that are practical to test. With the developed framework, if software defects are discovered, it will be easy to create one or more test cases to reproduce the defect and ensure that code changes correct the defect. These tests con rm HDTS version 2017.0 performs according to its specifications and documentation and that its performance meets the needs of its users at the Savannah River Site.

  19. Small-scale fixed wing airplane software verification flight test

    Science.gov (United States)

    Miller, Natasha R.

    The increased demand for micro Unmanned Air Vehicles (UAV) driven by military requirements, commercial use, and academia is creating a need for the ability to quickly and accurately conduct low Reynolds Number aircraft design. There exist several open source software programs that are free or inexpensive that can be used for large scale aircraft design, but few software programs target the realm of low Reynolds Number flight. XFLR5 is an open source, free to download, software program that attempts to take into consideration viscous effects that occur at low Reynolds Number in airfoil design, 3D wing design, and 3D airplane design. An off the shelf, remote control airplane was used as a test bed to model in XFLR5 and then compared to flight test collected data. Flight test focused on the stability modes of the 3D plane, specifically the phugoid mode. Design and execution of the flight tests were accomplished for the RC airplane using methodology from full scale military airplane test procedures. Results from flight test were not conclusive in determining the accuracy of the XFLR5 software program. There were several sources of uncertainty that did not allow for a full analysis of the flight test results. An off the shelf drone autopilot was used as a data collection device for flight testing. The precision and accuracy of the autopilot is unknown. Potential future work should investigate flight test methods for small scale UAV flight.

  20. TEST/QA PLAN FOR THE VERIFICATION TESTING OF ALTERNATIVES OR REFORMULATED LIQUID FUELS, FUEL ADDITIVES, FUEL EMULSONS, AND LUBRICANTS FOR HIGHWAY AND NONROAD USE HEAVY DUTY DIESEL ENGINES AND LIGHT DUTY GASOLINE ENGINES AND VEHICLES

    Science.gov (United States)

    The U.S. Environmental Protection Agency established the Environmental Technology Verification Program to accelerate the development and commercialization of improved environmental technology through third party verification and reporting of product performance. Research Triangl...

  1. Shaking table test and verification of development of an ...

    Indian Academy of Sciences (India)

    A full-scale multiple degrees of freedom shaking table is tested toverify the energy dissipation of this proposed AIC, including test building without control, with passive control added involving various stiffness ratios and also with synchronic control added involving various stiffness ratios. Shock absorption of displacement ...

  2. CTBT verification-related technologies for peaceful purposes: the French experiences of international cooperation

    International Nuclear Information System (INIS)

    Massinon, B.

    1999-01-01

    The French experience concerning CTBT verification-related technologies for peaceful purposes as well a the international cooperation in this field are presented. Possible objectives and cooperation program needs are cited. French experience in international cooperation is related to seismology and seismic hazards in Bolivia, Madagascar, Nepal and Indonesia and is considered as very constructive, meaning that technical experience is developed, consistent scientific results are obtained, and a considerable yield to the CTBT task is achieved. Large scientific benefits are expected from the CTBTO

  3. Independent verification and validation testing of the FLASH computer code, Versiion 3.0

    International Nuclear Information System (INIS)

    Martian, P.; Chung, J.N.

    1992-06-01

    Independent testing of the FLASH computer code, Version 3.0, was conducted to determine if the code is ready for use in hydrological and environmental studies at various Department of Energy sites. This report describes the technical basis, approach, and results of this testing. Verification tests, and validation tests, were used to determine the operational status of the FLASH computer code. These tests were specifically designed to test: correctness of the FORTRAN coding, computational accuracy, and suitability to simulating actual hydrologic conditions. This testing was performed using a structured evaluation protocol which consisted of: blind testing, independent applications, and graduated difficulty of test cases. Both quantitative and qualitative testing was performed through evaluating relative root mean square values and graphical comparisons of the numerical, analytical, and experimental data. Four verification test were used to check the computational accuracy and correctness of the FORTRAN coding, and three validation tests were used to check the suitability to simulating actual conditions. These tests cases ranged in complexity from simple 1-D saturated flow to 2-D variably saturated problems. The verification tests showed excellent quantitative agreement between the FLASH results and analytical solutions. The validation tests showed good qualitative agreement with the experimental data. Based on the results of this testing, it was concluded that the FLASH code is a versatile and powerful two-dimensional analysis tool for fluid flow. In conclusion, all aspects of the code that were tested, except for the unit gradient bottom boundary condition, were found to be fully operational and ready for use in hydrological and environmental studies

  4. Structure-dynamic model verification calculation of PWR 5 tests

    International Nuclear Information System (INIS)

    Engel, R.

    1980-02-01

    Within reactor safety research project RS 16 B of the German Federal Ministry of Research and Technology (BMFT), blowdown experiments are conducted at Battelle Institut e.V. Frankfurt/Main using a model reactor pressure vessel with a height of 11,2 m and internals corresponding to those in a PWR. In the present report the dynamic loading on the pressure vessel internals (upper perforated plate and barrel suspension) during the DWR 5 experiment are calculated by means of a vertical and horizontal dynamic model using the CESHOCK code. The equations of motion are resolved by direct integration. (orig./RW) [de

  5. EVA Development and Verification Testing at NASA's Neutral Buoyancy Laboratory

    Science.gov (United States)

    Jairala, Juniper C.; Durkin, Robert; Marak, Ralph J.; Sipila, Stepahnie A.; Ney, Zane A.; Parazynski, Scott E.; Thomason, Arthur H.

    2012-01-01

    As an early step in the preparation for future Extravehicular Activities (EVAs), astronauts perform neutral buoyancy testing to develop and verify EVA hardware and operations. Neutral buoyancy demonstrations at NASA Johnson Space Center's Sonny Carter Training Facility to date have primarily evaluated assembly and maintenance tasks associated with several elements of the International Space Station (ISS). With the retirement of the Shuttle, completion of ISS assembly, and introduction of commercial players for human transportation to space, evaluations at the Neutral Buoyancy Laboratory (NBL) will take on a new focus. Test objectives are selected for their criticality, lack of previous testing, or design changes that justify retesting. Assembly tasks investigated are performed using procedures developed by the flight hardware providers and the Mission Operations Directorate (MOD). Orbital Replacement Unit (ORU) maintenance tasks are performed using a more systematic set of procedures, EVA Concept of Operations for the International Space Station (JSC-33408), also developed by the MOD. This paper describes the requirements and process for performing a neutral buoyancy test, including typical hardware and support equipment requirements, personnel and administrative resource requirements, examples of ISS systems and operations that are evaluated, and typical operational objectives that are evaluated.

  6. Shaking table test and verification of development of an ...

    Indian Academy of Sciences (India)

    ... semi-active hydraulic damper (ASHD) is converted to interaction element (IE) of active interaction control (AIC). Systemic equations of motion, control law and control rulers of this proposed new AIC are studied in this research. A full-scale multiple degrees of freedom shaking table is tested toverify the energy dissipation of ...

  7. Target Soil Impact Verification: Experimental Testing and Kayenta Constitutive Modeling.

    Energy Technology Data Exchange (ETDEWEB)

    Broome, Scott Thomas [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Flint, Gregory Mark [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Dewers, Thomas [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Newell, Pania [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-11-01

    This report details experimental testing and constitutive modeling of sandy soil deformation under quasi - static conditions. This is driven by the need to understand constitutive response of soil to target/component behavior upon impact . An experimental and constitutive modeling program was followed to determine elastic - plastic properties and a compressional failure envelope of dry soil . One hydrostatic, one unconfined compressive stress (UCS), nine axisymmetric compression (ACS) , and one uniaxial strain (US) test were conducted at room temperature . Elastic moduli, assuming isotropy, are determined from unload/reload loops and final unloading for all tests pre - failure and increase monotonically with mean stress. Very little modulus degradation was discernable from elastic results even when exposed to mean stresses above 200 MPa . The failure envelope and initial yield surface were determined from peak stresses and observed onset of plastic yielding from all test results. Soil elasto - plastic behavior is described using the Brannon et al. (2009) Kayenta constitutive model. As a validation exercise, the ACS - parameterized Kayenta model is used to predict response of the soil material under uniaxial strain loading. The resulting parameterized and validated Kayenta model is of high quality and suitable for modeling sandy soil deformation under a range of conditions, including that for impact prediction.

  8. 12{sup th} Verification of the Charpy Impact Test Machine in IMEF

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Woo Seog; Kim, Gil Soo; Choo, Yong Sun; Ahn, Sang Bok [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-05-15

    Neutron radiation embrittlement of reactor vessel steels is one of the key parameters to limit the lifetime of nuclear reactors. The radiation-induced changes in the impact property of ferritic steels in the reactors have to be monitored through surveillance programs. In order to define the resistance to brittle fracture of a material when a crack is present, the Charpy impact test is done by using a pendulum and basic physics to measure the absorbed energy of a notched specimen. A Charpy impact machine is a major apparatus in the IMEF hot cells of KAERI for testing the irradiated materials. In hot cells, the machine and specimens are handled using manipulators, so the machine is able to be verified indirectly. The IMEF has carried out the indirect verification annually, and the results of the 12{sup th} verification test in 2011 are summarized in the paper

  9. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: UTC FUEL CELLS' PC25C POWER PLANT - GAS PROCESSING UNIT PERFORMANCE FOR ANAEROBIC DIGESTER GAS

    Science.gov (United States)

    Under EPA’s Environmental Technology Verification program, which provides objective and scientific third party analysis of new technology that can benefit the environment, a combined heat and power system based on the UTC Fuel Cell's PC25C Fuel Cell Power Plant was evaluated. The...

  10. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT-A AND A ENVIRONMENTAL SEALS, INC., SEAL ASSIST SYSTEM (SAS) PHASE II REPORT

    Science.gov (United States)

    The Environmental Technology Verification report discusses the technology and performance of Seal Assist System (SAS) for natural gas reciprocating compressor rod packing manufactured by A&A Environmental Seals, Inc. The SAS uses a secondary containment gland to collect natural g...

  11. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: RESIDENTIAL ELECTRIC POWER GENERATION USING THE PLUG POWER SU1 FUEL CELL SYSTEM

    Science.gov (United States)

    The Environmental Technology Verification report discusses the technology and performance of the Plug Power SU1 Fuel Cell System manufactured by Plug Power. The SU1 is a proton exchange membrane fuel cell that requires hydrogen (H2) as fuel. H2 is generally not available, so the ...

  12. Test ban treaty verification with regional data: a review

    International Nuclear Information System (INIS)

    Pomeroy, P.W.; Best, W.J.; McEvilly, T.V.

    1982-01-01

    This paper summarizes the use of regional (Δ ≤ 30 0 ) seismic data in a test ban context for detecting, locating, identifying, and determining the yield of underground nuclear explosions. In many areas of the world (Eastern North America, Africa, Eastern USSR), Lg is the largest amplitude wave recorded on standard seismograph systems and thus is the most appropriate phase for monitoring small magnitude events. Excellent location capability for near-regional events has been demonstrated at the Norwegian small aperture array (NORESS) using Lg and P waves. Lg and other regional phases may contain information on source depth, but such information has not been exploited to date. Fifteen classes of regional discriminants are listed. Most have been tested only on limited data, usually from one geographic region and only one or two recording stations. No systematic analyses have been done to determine the best individual discriminant or combination of them. Preliminary evaluation of the use of Lg for yield determination suggests that regional waves hold promise in this application. Theoretical studies have contributed significantly to the understanding of propagation characteristics of regional waves but further studies are required emphasizing modeling for realistic anisotropic sources. The major conclusion of this study is that a systematic and comparative evaluation of all the proposed regional discriminants is now required, utilizing a common data base derived from all present-day test sites. This evaluation would suggest the optimal discrimination procedure using regional waves, and would also define areas of needed research. Without such an integrated evaluation, it is still possible to speculate, using existing results, on the most promising regional discriminants

  13. Development of an object test to dental image verification

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Paula S.S. [Instituto de Pesquisas Energeticas e Nucleares, Comissao Nacional de Energia Nuclear/SP, C.P. 11049-CEP, 05422-970-Sao Paulo (Brazil)], E-mail: psasaki@ipen.br; Potiens, Maria da Penha A. [Instituto de Pesquisas Energeticas e Nucleares, Comissao Nacional de Energia Nuclear/SP, C.P. 11049-CEP, 05422-970-Sao Paulo (Brazil)], E-mail: mppalbu@ipen.br

    2010-04-15

    An object test was developed to verify the dental images best quality in relation to the exposition time. It consists of high purity perforated aluminum plates, with different thickness and dimensions of 3x4 cm. The plates were covered by acrylic, making its total thickness of 3.0 mm. It was irradiated together with the film from 0.1 to 0.5 s. The irradiation of 0.2 s showed the best image, reducing the regular time exposition by 0.3 s.

  14. Experimental Verification of an Instrument to Test Flooring Materials

    Science.gov (United States)

    Philip, Rony; Löfgren, Hans, Dr

    2018-02-01

    The focus of this work is to validate the fluid model with different flooring materials and the measurements of an instrument to test flooring materials and its force attenuating capabilities using mathematical models to describe the signature and coefficients of the floor. The main contribution of the present work focus on the development of a mathematical fluid model for floors. The aim of the thesis was to analyze, compare different floor materials and to study the linear dynamics of falling impacts on floors. The impact of the hammer during a fall is captured by an accelerometer and response is collected using a picoscope. The collected data was analyzed using matlab least square method which is coded as per the fluid model. The finding from this thesis showed that the fluid model works with more elastic model but it doesn’t work for rigid materials like wood. The importance of parameters like velocity, mass, energy loss and other coefficients of floor which influences the model during the impact of falling on floors were identified and a standardized testing method was set.

  15. Test and Verification of AES Used for Image Encryption

    Science.gov (United States)

    Zhang, Yong

    2018-03-01

    In this paper, an image encryption program based on AES in cipher block chaining mode was designed with C language. The encryption/decryption speed and security performance of AES based image cryptosystem were tested and used to compare the proposed cryptosystem with some existing image cryptosystems based on chaos. Simulation results show that AES can apply to image encryption, which refutes the widely accepted point of view that AES is not suitable for image encryption. This paper also suggests taking the speed of AES based image encryption as the speed benchmark of image encryption algorithms. And those image encryption algorithms whose speeds are lower than the benchmark should be discarded in practical communications.

  16. Development and verification test of integral reactor major components

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. I.; Kim, Y. W.; Kim, J. H. and others

    1999-03-01

    The conceptual designs for SG, MCP, CEDM to be installed in the integral reactor SMART were developed. Three-dimensional CAD models for the major components were developed to visualize the design concepts. Once-through helical steam generator was conceptually designed for SMART. Canned motor pump was adopted in the conceptual design of MCP. Linear pulse motor type and ballscrew type CEDM, which have fine control capabilities were studied for adoption in SMART. In parallel with the structural design, the electro-magnetic design was performed for the sizing motors and electro-magnet. Prototypes for the CEDM and MCP sub-assemblies were developed and tested to verify the performance. The impeller design procedure and the computer program to analyze the dynamic characteristics of MCP rotor shaft were developed. The design concepts of SG, MCP, CEDM were also invetigated for the fabricability.

  17. Development and verification test of integral reactor major components

    International Nuclear Information System (INIS)

    Kim, J. I.; Kim, Y. W.; Kim, J. H. and others

    1999-03-01

    The conceptual designs for SG, MCP, CEDM to be installed in the integral reactor SMART were developed. Three-dimensional CAD models for the major components were developed to visualize the design concepts. Once-through helical steam generator was conceptually designed for SMART. Canned motor pump was adopted in the conceptual design of MCP. Linear pulse motor type and ballscrew type CEDM, which have fine control capabilities were studied for adoption in SMART. In parallel with the structural design, the electro-magnetic design was performed for the sizing motors and electro-magnet. Prototypes for the CEDM and MCP sub-assemblies were developed and tested to verify the performance. The impeller design procedure and the computer program to analyze the dynamic characteristics of MCP rotor shaft were developed. The design concepts of SG, MCP, CEDM were also invetigated for the fabricability

  18. Evaluation of detector array technology for the verification of advanced intensity-modulated radiotherapy

    Science.gov (United States)

    Hussien, Mohammad

    Purpose: Quality assurance (QA) for intensity modulated radiotherapy (IMRT) has evolved substantially. In recent years, various ionization chamber or diode detector arrays have become commercially available, allowing pre-treatment absolute dose verification with near real-time results. This has led to a wide uptake of this technology to replace point dose and film dosimetry and to facilitate QA streamlining. However, arrays are limited by their spatial resolution giving rise to concerns about their response to clinically relevant deviations. The common factor in all commercial array systems is the reliance on the gamma index (γ) method to provide the quantitative evaluation of the measured dose distribution against the Treatment Planning System (TPS) calculated dose distribution. The mathematical definition of the gamma index presents computational challenges that can cause a variation in the calculation in different systems. The purpose of this thesis was to evaluate the suitability of detector array systems, combined with their implementation of the gamma index, in the verification and dosimetry audit of advanced IMRT. Method: The response of various commercial detector array systems (Delta4®, ArcCHECK®, and the PTW 2D-Array seven29™ and OCTAVIUS II™ phantom combination, Gafchromic® EBT2 and composite EPID measurements) to simulated deliberate changes in clinical IMRT and VMAT plans was evaluated. The variability of the gamma index calculation in the different systems was also evaluated by comparing against a bespoke Matlab-based gamma index analysis software. A novel methodology for using a commercial detector array in a dosimetry audit of rotational radiotherapy was then developed. Comparison was made between measurements using the detector array and those performed using ionization chambers, alanine and radiochromic film. The methodology was developed as part of the development of a national audit of rotational radiotherapy. Ten cancer centres were

  19. Shear Ram Verification Test Protocol (VTP) Best Practices

    Energy Technology Data Exchange (ETDEWEB)

    Lindley, Roy A. [Argonne National Lab. (ANL), Argonne, IL (United States); Braun, Joseph C. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2017-01-01

    A blowout preventer (BOP) is a critical component used on subsea oil and gas wells during drilling, completion, and workover operations on the U. S. outer continental shelf (OCS). The purpose of the BOP is to seal oil and gas wells, and in the case of an emergency well-control event, to prevent the uncontrolled release of hydrocarbons. One of the most important components of the BOP is the hydraulically operated blind shear ram (BSR) that shears drilling-related components, such as drill pipes, casings, tubings, and wire-related tools that may have been placed in the well. In addition to shearing these components, the BSR must form a seal to keep hydrocarbons within the well bore, even when under the highest well-fluid pressures expected. The purpose of this document is for Argonne National Laboratory (ANL) to provide an independent view, based on current regulations, and best practices for testing and confirming the operability and suitability of BSRs under realistic (or actual) well conditions.

  20. Probabilistic Requirements (Partial) Verification Methods Best Practices Improvement. Variables Acceptance Sampling Calculators: Empirical Testing. Volume 2

    Science.gov (United States)

    Johnson, Kenneth L.; White, K. Preston, Jr.

    2012-01-01

    The NASA Engineering and Safety Center was requested to improve on the Best Practices document produced for the NESC assessment, Verification of Probabilistic Requirements for the Constellation Program, by giving a recommended procedure for using acceptance sampling by variables techniques as an alternative to the potentially resource-intensive acceptance sampling by attributes method given in the document. In this paper, the results of empirical tests intended to assess the accuracy of acceptance sampling plan calculators implemented for six variable distributions are presented.

  1. Comprehensive Nuclear-Test-Ban Treaty: Science and Technology 2011 (S and T2011). Announcement

    International Nuclear Information System (INIS)

    2011-01-01

    To build and strengthen its relationship with the broader science community in support of the Treaty, the Preparatory Commission for the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) invites the community to a scientific conference CTBT: Science and Technology 2011 (S and T 2011), to be held from 8 to 10 June 2011 at the Hofburg Palace in Vienna, Austria. The conference goals are: Discuss advances in science and technology relevant to test ban verification; Explore scientific applications of the CTBT verification infrastructure; Encourage partnerships and knowledge exchange between the CTBTO and the broader scientific community.

  2. Benchmark testing and independent verification of the VS2DT computer code

    International Nuclear Information System (INIS)

    McCord, J.T.

    1994-11-01

    The finite difference flow and transport simulator VS2DT was benchmark tested against several other codes which solve the same equations (Richards equation for flow and the Advection-Dispersion equation for transport). The benchmark problems investigated transient two-dimensional flow in a heterogeneous soil profile with a localized water source at the ground surface. The VS2DT code performed as well as or better than all other codes when considering mass balance characteristics and computational speed. It was also rated highly relative to the other codes with regard to ease-of-use. Following the benchmark study, the code was verified against two analytical solutions, one for two-dimensional flow and one for two-dimensional transport. These independent verifications show reasonable agreement with the analytical solutions, and complement the one-dimensional verification problems published in the code's original documentation

  3. Verification and Validation of Adaptive and Intelligent Systems with Flight Test Results

    Science.gov (United States)

    Burken, John J.; Larson, Richard R.

    2009-01-01

    F-15 IFCS project goals are: a) Demonstrate Control Approaches that can Efficiently Optimize Aircraft Performance in both Normal and Failure Conditions [A] & [B] failures. b) Advance Neural Network-Based Flight Control Technology for New Aerospace Systems Designs with a Pilot in the Loop. Gen II objectives include; a) Implement and Fly a Direct Adaptive Neural Network Based Flight Controller; b) Demonstrate the Ability of the System to Adapt to Simulated System Failures: 1) Suppress Transients Associated with Failure; 2) Re-Establish Sufficient Control and Handling of Vehicle for Safe Recovery. c) Provide Flight Experience for Development of Verification and Validation Processes for Flight Critical Neural Network Software.

  4. Examples of verification knowledge and testing of the secondary students through the worksheet. Suggestions for leisure time activities

    International Nuclear Information System (INIS)

    Chmielewska, E.; Kuruc, J.

    2010-01-01

    In this chapter some examples of verification knowledge and testing of the secondary students through the worksheet as well as suggestions for leisure time activities are presented. Used and recommended literature is included.

  5. Non proliferation regimes undertakings: Benefits and limits of synergies in verification technologies and procedures

    International Nuclear Information System (INIS)

    Richard, M.

    2001-01-01

    Full text: Thirty years ago the NPT was entering into force. Therewith, when a State became party to the NPT, it had, in accordance with article III.1 of the Treaty, an undertaking to conclude a Comprehensive Safeguards agreement with the IAEA and accept safeguards verification on source or special fissionable material in all peaceful nuclear activities within its territories in order to verify that such material is not diverted. This multilateral instrument was the foundation stone of the non-proliferation regime and marked the actual birth of internationally accepted measures to verily compliance with politically stringent agreements. Since that time several important multilateral or bilateral instruments on non-proliferation and disarmament have been negotiated and adopted to curb the development and the acquisition of Weapons of Mass Destruction (WMD) most of them since the middle of the eighties and the collapse of the Soviet Union. Amongst the multilateral instruments are the Convention on the Prohibition of Bacteriological Weapon and Toxin Weapons (1972), the Convention on the Prohibition of Chemical Weapons (1993), the Comprehensive Test Ban Treaty (1996), the Strengthening of the IAEA Safeguards and the Additional Protocol (1997), with some still in negotiation like the Protocol of the Convention on the Prohibition of Bacteriological and Toxin Weapons, and some on which negotiation is still a wish like the Fissile Material Cut-off Treaty. Bilateral disarmament agreements between the United States of America and the Russian Federation such as the INF Treaty, START I and II, the agreements on the elimination of excess defence nuclear material as well as the Trilateral Initiative with the IAEA pave the way to nuclear disarmament with the reduction of both the number of nuclear weapons arsenal and the fissile material inventories. The politically stringent undertakings of States that have become parties to those agreements would not be possible without the

  6. Power Performance Verification of a Wind Farm Using the Friedman's Test.

    Science.gov (United States)

    Hernandez, Wilmar; López-Presa, José Luis; Maldonado-Correa, Jorge L

    2016-06-03

    In this paper, a method of verification of the power performance of a wind farm is presented. This method is based on the Friedman's test, which is a nonparametric statistical inference technique, and it uses the information that is collected by the SCADA system from the sensors embedded in the wind turbines in order to carry out the power performance verification of a wind farm. Here, the guaranteed power curve of the wind turbines is used as one more wind turbine of the wind farm under assessment, and a multiple comparison method is used to investigate differences between pairs of wind turbines with respect to their power performance. The proposed method says whether the power performance of the specific wind farm under assessment differs significantly from what would be expected, and it also allows wind farm owners to know whether their wind farm has either a perfect power performance or an acceptable power performance. Finally, the power performance verification of an actual wind farm is carried out. The results of the application of the proposed method showed that the power performance of the specific wind farm under assessment was acceptable.

  7. Power Performance Verification of a Wind Farm Using the Friedman’s Test

    Science.gov (United States)

    Hernandez, Wilmar; López-Presa, José Luis; Maldonado-Correa, Jorge L.

    2016-01-01

    In this paper, a method of verification of the power performance of a wind farm is presented. This method is based on the Friedman’s test, which is a nonparametric statistical inference technique, and it uses the information that is collected by the SCADA system from the sensors embedded in the wind turbines in order to carry out the power performance verification of a wind farm. Here, the guaranteed power curve of the wind turbines is used as one more wind turbine of the wind farm under assessment, and a multiple comparison method is used to investigate differences between pairs of wind turbines with respect to their power performance. The proposed method says whether the power performance of the specific wind farm under assessment differs significantly from what would be expected, and it also allows wind farm owners to know whether their wind farm has either a perfect power performance or an acceptable power performance. Finally, the power performance verification of an actual wind farm is carried out. The results of the application of the proposed method showed that the power performance of the specific wind farm under assessment was acceptable. PMID:27271628

  8. Power Performance Verification of a Wind Farm Using the Friedman’s Test

    Directory of Open Access Journals (Sweden)

    Wilmar Hernandez

    2016-06-01

    Full Text Available In this paper, a method of verification of the power performance of a wind farm is presented. This method is based on the Friedman’s test, which is a nonparametric statistical inference technique, and it uses the information that is collected by the SCADA system from the sensors embedded in the wind turbines in order to carry out the power performance verification of a wind farm. Here, the guaranteed power curve of the wind turbines is used as one more wind turbine of the wind farm under assessment, and a multiple comparison method is used to investigate differences between pairs of wind turbines with respect to their power performance. The proposed method says whether the power performance of the specific wind farm under assessment differs significantly from what would be expected, and it also allows wind farm owners to know whether their wind farm has either a perfect power performance or an acceptable power performance. Finally, the power performance verification of an actual wind farm is carried out. The results of the application of the proposed method showed that the power performance of the specific wind farm under assessment was acceptable.

  9. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: BAGHOUSE FILTRATION PRODUCTS, BWF AMERICA, INC. GRADE 700 MPS POLYESTER FELT FILTER SAMPLE

    Science.gov (United States)

    Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) Verification Center. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of the size for particles equal to or smaller than...

  10. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: BAGHOUSE FILTRATION PRODUCTS, W.L. GORE & ASSOCIATES, INC. LYSB3 FILTER SAMPLE

    Science.gov (United States)

    Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) Verification Center. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of the size for particles equal to or smaller than...

  11. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, BAGHOUSE FILTRATION PRODUCTS, W.L. GORE & ASSOCIATES, INC., L4427 FILTER SAMPLE

    Science.gov (United States)

    Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) Verification Center. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of the size of those particles equal to and smalle...

  12. Application of software technology to automatic test data analysis

    Science.gov (United States)

    Stagner, J. R.

    1991-01-01

    The verification process for a major software subsystem was partially automated as part of a feasibility demonstration. The methods employed are generally useful and applicable to other types of subsystems. The effort resulted in substantial savings in test engineer analysis time and offers a method for inclusion of automatic verification as a part of regression testing.

  13. Charpy impact test results on five materials and NIST verification specimens using instrumented 2-mm and 8-mm strikers

    International Nuclear Information System (INIS)

    Nanstad, R.K.; Sokolov, M.A.

    1995-01-01

    The Heavy-Section Steel Irradiation Program at Oak Ridge National Laboratory is involved in two cooperative projects, with international participants, both of which involve Charpy V-notch impact tests with instrumented strikers of 2mm and 8mm radii. Two heats of A 533 grade B class I pressure vessel steel and a low upper-shelf (LUS) submerged-arc (SA) weld were tested on the same Charpy machine, while one heat of a Russian Cr-Mo-V forging steel and a high upper-shelf (HUS) SA weld were tested on two different machines. The number of replicate tests at any one temperature ranged from 2 to 46 specimens. Prior to testing with each striker, verification specimens at the low, high, and super high energy levels from the National Institute of Standards and Technology (NIST) were tested. In the two series of verification tests, the tests with the 2mm striker met the requirements at the low and high energy levels but not at the super high energy. For one plate, the 2mm striker showed somewhat higher average absorbed energies than those for the 8-mm striker at all three test temperatures. For the second plate and the LUS weld, however, the 2mm striker showed somewhat lower energies at both test temperatures. For the Russian forging steel and the HUS weld, tests were conducted over a range of temperatures with tests at one laboratory using the 8mm striker and tests at a second laboratory using the 2mm striker. Lateral expansion was measured for all specimens and the results are compared with the absorbed energy results. The overall results showed generally good agreement (within one standard deviation) in energy measurements by the two strikers. Load-time traces from the instrumented strikers were also compared and used to estimate shear fracture percentage. Four different formulas from the European Structural Integrity Society draft standard for instrumented Charpy test are compared and a new formula is proposed for estimation of percent shear from the force-time trace

  14. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: HVLP COATING EQUIPMENT, ITW AUTOMOTIVE REFINISHING, DEVILBISS FLG-631-318 HVLP SPRAY GUN

    Science.gov (United States)

    This report presents the results of the verification test of the DeVilbiss FLG-631-318 high-volume, low-pressure gravity-feed spray gun, hereafter referred to as the DeVilbiss FLG, which is designed for use in automotive refinishing. The test coating chosen by ITW Automotive Refi...

  15. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: HVLP COATING EQUIPMENT, ITW AUTOMOTIVE REFINISHING, DEVILBISS GTI-600G, HVLP SPRAY GUN

    Science.gov (United States)

    This report presents the results of the verification test of the DeVilbiss GTi-600G high-volume, low-pressure gravity-feed spray gun, hereafter referred to as the DeVilbiss GTi, which is designed for use in automotive refinishing. The test coating chosen by ITW Automotive Refinis...

  16. Selected Examples of LDRD Projects Supporting Test Ban Treaty Verification and Nonproliferation

    Energy Technology Data Exchange (ETDEWEB)

    Jackson, K. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Al-Ayat, R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Walter, W. R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-02-23

    The Laboratory Directed Research and Development (LDRD) Program at the DOE National Laboratories was established to ensure the scientific and technical vitality of these institutions and to enhance the their ability to respond to evolving missions and anticipate national needs. LDRD allows the Laboratory directors to invest a percentage of their total annual budget in cutting-edge research and development projects within their mission areas. We highlight a selected set of LDRD-funded projects, in chronological order, that have helped provide capabilities, people and infrastructure that contributed greatly to our ability to respond to technical challenges in support of test ban treaty verification and nonproliferation.

  17. Validation, Verification, and Testing Techniques Throughout the Life Cycle of a Simulation Study

    OpenAIRE

    1994-01-01

    Life cycle validation, verification, and testing (VV&T) is extremely important for the success of a simulation study. This paper surveys current software VV&T techniques and current simulation model VV&T techniques and describes how they can all be applied throughout the life cycle of a simulation study. The processes and credibility assessment stages of the life cycle are described and the applicability of the VV&T techniques for each stage is stated. A glossary is provided to explicitly ...

  18. Bias associated with delayed verification in test accuracy studies: accuracy of tests for endometrial hyperplasia may be much higher than we think!

    Directory of Open Access Journals (Sweden)

    Coomarasamy Aravinthan

    2004-05-01

    Full Text Available Abstract Background To empirically evaluate bias in estimation of accuracy associated with delay in verification of diagnosis among studies evaluating tests for predicting endometrial hyperplasia. Methods Systematic reviews of all published research on accuracy of miniature endometrial biopsy and endometr ial ultrasonography for diagnosing endometrial hyperplasia identified 27 test accuracy studies (2,982 subjects. Of these, 16 had immediate histological verification of diagnosis while 11 had verification delayed > 24 hrs after testing. The effect of delay in verification of diagnosis on estimates of accuracy was evaluated using meta-regression with diagnostic odds ratio (dOR as the accuracy measure. This analysis was adjusted for study quality and type of test (miniature endometrial biopsy or endometrial ultrasound. Results Compared to studies with immediate verification of diagnosis (dOR 67.2, 95% CI 21.7–208.8, those with delayed verification (dOR 16.2, 95% CI 8.6–30.5 underestimated the diagnostic accuracy by 74% (95% CI 7%–99%; P value = 0.048. Conclusion Among studies of miniature endometrial biopsy and endometrial ultrasound, diagnostic accuracy is considerably underestimated if there is a delay in histological verification of diagnosis.

  19. Optical Testing and Verification Methods for the James Webb Space Telescope Integrated Science Instrument Module Element

    Science.gov (United States)

    Antonille, Scott R.; Miskey, Cherie L.; Ohl, Raymond G.; Rohrbach, Scott O.; Aronstein, David L.; Bartoszyk, Andrew E.; Bowers, Charles W.; Cofie, Emmanuel; Collins, Nicholas R.; Comber, Brian J.; hide

    2016-01-01

    NASA's James Webb Space Telescope (JWST) is a 6.6m diameter, segmented, deployable telescope for cryogenic IR space astronomy (40K). The JWST Observatory includes the Optical Telescope Element (OTE) and the Integrated Science Instrument Module (ISIM) that contains four science instruments (SI) and the fine guider. The SIs are mounted to a composite metering structure. The SI and guider units were integrated to the ISIM structure and optically tested at the NASA Goddard Space Flight Center as a suite using the Optical Telescope Element SIMulator (OSIM). OSIM is a full field, cryogenic JWST telescope simulator. SI performance, including alignment and wave front error, were evaluated using OSIM. We describe test and analysis methods for optical performance verification of the ISIM Element, with an emphasis on the processes used to plan and execute the test. The complexity of ISIM and OSIM drove us to develop a software tool for test planning that allows for configuration control of observations, associated scripts, and management of hardware and software limits and constraints, as well as tools for rapid data evaluation, and flexible re-planning in response to the unexpected. As examples of our test and analysis approach, we discuss how factors such as the ground test thermal environment are compensated in alignment. We describe how these innovative methods for test planning and execution and post-test analysis were instrumental in the verification program for the ISIM element, with enough information to allow the reader to consider these innovations and lessons learned in this successful effort in their future testing for other programs.

  20. Conspray dynamic sleeve piston coal feeder. Phase II. Verification tests. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    1984-01-26

    This report details the performance of Phase II: Verification Tests of the Conspray dynamic sleeve piston coal feeder. The machine performed for 200 hours at 700 psi backpressure, utilizing a 70% to 200 mesh Utah bituminous coal as feedstock. All test work was satisfactorily completed. A post-test inspection was performed. A report of component wear and failures incurred in testing is included as well as suggestions for machine upgrades. The overall conclusion is that the dynamic sleeve piston feeder has proven its ability to operate safely and reliably. When problems have occurred, the machine has demonstrated inherent safety by shutting down without endangering process or personnel. With the recommended improvements incorporated into the feeder, the unit will be ready for installation on a pilot scale coal gasifier. 9 figures, 11 tables.

  1. The nuclear test-ban verification regime: An untapped source for climate change monitoring

    International Nuclear Information System (INIS)

    2008-12-01

    The benefits of a global ban on nuclear testing for international security and for protecting human health and the environment from radioactive fallout are obvious. The relevance of the Comprehensive Nuclear-Test-Ban Treaty (CTBT) for climate change research may not, however, be evident at first glance. The CTBT bans all nuclear explosions on Earth. To monitor compliance with the Treaty, the CTBTO Preparatory Commission for the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO), is establishing a verification regime capable of detecting clandestine nuclear tests. As the only international body operating its own system of monitoring stations that literally spans the globe, the CTBTO is in a unique position to contribute to the UN's efforts in the area of climate knowledge.

  2. Standard practices for verification of displacement measuring systems and devices used in material testing machines

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 These practices cover procedures and requirements for the calibration and verification of displacement measuring systems by means of standard calibration devices for static and quasi-static testing machines. This practice is not intended to be complete purchase specifications for testing machines or displacement measuring systems. Displacement measuring systems are not intended to be used for the determination of strain. See Practice E83. 1.2 These procedures apply to the verification of the displacement measuring systems associated with the testing machine, such as a scale, dial, marked or unmarked recorder chart, digital display, etc. In all cases the buyer/owner/user must designate the displacement-measuring system(s) to be verified. 1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems m...

  3. Process Sensitivity, Performance, and Direct Verification Testing of Adhesive Locking Features

    Science.gov (United States)

    Golden, Johnny L.; Leatherwood, Michael D.; Montoya, Michael D.; Kato, Ken A.; Akers, Ed

    2012-01-01

    during assembly by measuring the dynamic prevailing torque. Adhesive locking features or LLCs are another method of providing redundant locking, but a direct verification method has not been used in aerospace applications to verify proper installation when using LLCs because of concern for damage to the adhesive bond. The reliability of LLCs has also been questioned due to failures observed during testing with coupons for process verification, although the coupon failures have often been attributed to a lack of proper procedures. It is highly desirable to have a direct method of verifying the LLC cure or bond integrity. The purpose of the Phase II test program was to determine if the torque applied during direct verification of an adhesive locking feature degrades that locking feature. This report documents the test program used to investigate the viability of such a direct verification method. Results of the Phase II testing were positive, and additional investigation of direct verification of adhesive locking features is merited.

  4. Bias associated with delayed verification in test accuracy studies: accuracy of tests for endometrial hyperplasia may be much higher than we think!

    OpenAIRE

    Clark, T Justin; ter Riet, Gerben; Coomarasamy, Aravinthan; Khan, Khalid S

    2004-01-01

    Abstract Background To empirically evaluate bias in estimation of accuracy associated with delay in verification of diagnosis among studies evaluating tests for predicting endometrial hyperplasia. Methods Systematic reviews of all published research on accuracy of miniature endometrial biopsy and endometr ial ultrasonography for diagnosing endometrial hyperplasia identified 27 test accuracy studies (2,982 subjects). Of these, 16 had immediate histological verification of diagnosis while 11 ha...

  5. The experimental verification of the condition of the magnetic material caused by different technological processes

    CERN Document Server

    Tumanski, S

    2000-01-01

    The changes of electrical steel parameters caused by different technological processes have been tested using the magnetovision method. The effects of cutting into the strips, stamping the shape, laser scribing, annealing, bending and stressing have been investigated.

  6. The Concept Verification Testing of a materials science payload. [for Spacelab experiment design

    Science.gov (United States)

    Griner, C. S.; Johnston, M. H.; Whitaker, A. F.

    1975-01-01

    The Concept Verification Testing (CVT) project at the Marshall Space Flight Center, Alabama is a developmental activity that supports Shuttle Payload projects such as Spacelab. It provides an operational one-g environment for testing NASA and other agency experiment and support systems concepts that may be used in Shuttle. A dedicated Materials Science Payload was tested in the General Purpose Laboratory (GPL) in December 1974 in order to assess the requirements of a Space Processing payload on a Spacelab type facility. Physical and functional integration of the experiments into the facility was studied, and the impact of the experiments on the facility (and vice versa) was evaluated. The Principal Investigators (PI) who had proposed experiments were onboard and in a consulting status on the ground. The significant results of the week-long simulation will be discussed.

  7. Providing an empirical basis for optimizing the verification and testing phases of software development

    Science.gov (United States)

    Briand, Lionel C.; Basili, Victor R.; Hetmanski, Christopher J.

    1992-01-01

    Applying equal testing and verification effort to all parts of a software system is not very efficient, especially when resources are limited and scheduling is tight. Therefore, one needs to be able to differentiate low/high fault density components so that the testing/verification effort can be concentrated where needed. Such a strategy is expected to detect more faults and thus improve the resulting reliability of the overall system. This paper presents an alternative approach for constructing such models that is intended to fulfill specific software engineering needs (i.e. dealing with partial/incomplete information and creating models that are easy to interpret). Our approach to classification is as follows: (1) to measure the software system to be considered; and (2) to build multivariate stochastic models for prediction. We present experimental results obtained by classifying FORTRAN components developed at the NASA/GSFC into two fault density classes: low and high. Also we evaluate the accuracy of the model and the insights it provides into the software process.

  8. Development of an automated testing system for verification and validation of nuclear data

    International Nuclear Information System (INIS)

    Triplett, B. S.; Anghaie, S.; White, M. C.

    2008-01-01

    Verification and validation of nuclear data is critical to the accuracy of both stochastic and deterministic particle transport codes. In order to effectively test a set of nuclear data, the data must be applied to a wide variety of transport problems. Performing this task in a timely, efficient manner is tedious. The nuclear data team at Los Alamos National Laboratory (LANL) in collaboration with the University of Florida is developing a methodology to automate the process of nuclear data verification and validation. The International Criticality Safety Benchmark Experiment Project (ICSBEP) provides a set of criticality problems that may be used to evaluate nuclear data. This process tests a number of data libraries using cases from the ICSBEP benchmark set to demonstrate how automation of these tasks may reduce errors and increase efficiency. The process is driven by an integrated set of Python scripts. Material and geometry data may be read from an existing code input file to generate a standardized template or the template may be generated directly by the user The user specifies the desired precision and other vital problem parameters. The Python scripts generate input decks for multiple transport codes from these templates, run and monitor individual jobs, and parse the relevant output. This output can then be used to generate reports directly or can be stored into a database for later analysis. This methodology eases the burden on the user by reducing the amount of time and effort required for obtaining and compiling calculation results. (authors)

  9. Verification of cardiac mechanics software: benchmark problems and solutions for testing active and passive material behaviour.

    Science.gov (United States)

    Land, Sander; Gurev, Viatcheslav; Arens, Sander; Augustin, Christoph M; Baron, Lukas; Blake, Robert; Bradley, Chris; Castro, Sebastian; Crozier, Andrew; Favino, Marco; Fastl, Thomas E; Fritz, Thomas; Gao, Hao; Gizzi, Alessio; Griffith, Boyce E; Hurtado, Daniel E; Krause, Rolf; Luo, Xiaoyu; Nash, Martyn P; Pezzuto, Simone; Plank, Gernot; Rossi, Simone; Ruprecht, Daniel; Seemann, Gunnar; Smith, Nicolas P; Sundnes, Joakim; Rice, J Jeremy; Trayanova, Natalia; Wang, Dafang; Jenny Wang, Zhinuo; Niederer, Steven A

    2015-12-08

    Models of cardiac mechanics are increasingly used to investigate cardiac physiology. These models are characterized by a high level of complexity, including the particular anisotropic material properties of biological tissue and the actively contracting material. A large number of independent simulation codes have been developed, but a consistent way of verifying the accuracy and replicability of simulations is lacking. To aid in the verification of current and future cardiac mechanics solvers, this study provides three benchmark problems for cardiac mechanics. These benchmark problems test the ability to accurately simulate pressure-type forces that depend on the deformed objects geometry, anisotropic and spatially varying material properties similar to those seen in the left ventricle and active contractile forces. The benchmark was solved by 11 different groups to generate consensus solutions, with typical differences in higher-resolution solutions at approximately 0.5%, and consistent results between linear, quadratic and cubic finite elements as well as different approaches to simulating incompressible materials. Online tools and solutions are made available to allow these tests to be effectively used in verification of future cardiac mechanics software.

  10. Students' Use of Technological Tools for Verification Purposes in Geometry Problem Solving

    Science.gov (United States)

    Papadopoulos, Ioannis; Dagdilelis, Vassilios

    2008-01-01

    Despite its importance in mathematical problem solving, verification receives rather little attention by the students in classrooms, especially at the primary school level. Under the hypotheses that (a) non-standard tasks create a feeling of uncertainty that stimulates the students to proceed to verification processes and (b) computational…

  11. Research on key technology of the verification system of steel rule based on vision measurement

    Science.gov (United States)

    Jia, Siyuan; Wang, Zhong; Liu, Changjie; Fu, Luhua; Li, Yiming; Lu, Ruijun

    2018-01-01

    The steel rule plays an important role in quantity transmission. However, the traditional verification method of steel rule based on manual operation and reading brings about low precision and low efficiency. A machine vison based verification system of steel rule is designed referring to JJG1-1999-Verificaiton Regulation of Steel Rule [1]. What differentiates this system is that it uses a new calibration method of pixel equivalent and decontaminates the surface of steel rule. Experiments show that these two methods fully meet the requirements of the verification system. Measuring results strongly prove that these methods not only meet the precision of verification regulation, but also improve the reliability and efficiency of the verification system.

  12. Tensit - a novel probabilistic simulation tool for safety assessments. Tests and verifications using biosphere models

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Jakob; Vahlund, Fredrik; Kautsky, Ulrik

    2004-06-01

    This report documents the verification of a new simulation tool for dose assessment put together in a package under the name Tensit (Technical Nuclide Simulation Tool). The tool is developed to solve differential equation systems describing transport and decay of radionuclides. It is capable of handling both deterministic and probabilistic simulations. The verifications undertaken shows good results. Exceptions exist only where the reference results are unclear. Tensit utilise and connects two separate commercial softwares. The equation solving capability is derived from the Matlab/Simulink software environment to which Tensit adds a library of interconnectable building blocks. Probabilistic simulations are provided through a statistical software named at{sub R}isk that communicates with Matlab/Simulink. More information about these softwares can be found at www.palisade.com and www.mathworks.com. The underlying intention of developing this new tool has been to make available a cost efficient and easy to use means for advanced dose assessment simulations. The mentioned benefits are gained both through the graphical user interface provided by Simulink and at{sub R}isk, and the use of numerical equation solving routines in Matlab. To verify Tensit's numerical correctness, an implementation was done of the biosphere modules for dose assessments used in the earlier safety assessment project SR 97. Acquired probabilistic results for deterministic as well as probabilistic simulations have been compared with documented values. Additional verification has been made both with another simulation tool named AMBER and also against the international test case from PSACOIN named Level 1B. This report documents the models used for verification with equations and parameter values so that the results can be recreated. For a background and a more detailed description of the underlying processes in the models, the reader is referred to the original references. Finally, in the

  13. SASSYS-1 computer code verification with EBR-II test data

    International Nuclear Information System (INIS)

    Warinner, D.K.; Dunn, F.E.

    1985-01-01

    The EBR-II natural circulation experiment, XX08 Test 8A, is simulated with the SASSYS-1 computer code and the results for the latter are compared with published data taken during the transient at selected points in the core. The SASSYS-1 results provide transient temperature and flow responses for all points of interest simultaneously during one run, once such basic parameters as pipe sizes, initial core flows, and elevations are specified. The SASSYS-1 simulation results for the EBR-II experiment XX08 Test 8A, conducted in March 1979, are within the published plant data uncertainties and, thereby, serve as a partial verification/validation of the SASSYS-1 code

  14. TRAC-PF1 code verification with data from the OTIS test facility

    International Nuclear Information System (INIS)

    Childerson, M.T.; Fujits, R.K.

    1985-01-01

    A computer code (TRAC-PFI/MODI; denoted as TRAC) developed for predicting transient thermal and hydraulic integral nuclear steam supply system (NSSS) response was benchmarked. Post-small break loss-of-coolant accident (LOCA) data from a scaled, experimental facility, designated the Once-Through Integral Systems (OTIS), were obtained for the Babcock and Wilcox NSSS and compared to TRAC predictions. The OTIS tests provided a challenging small break LOCA data set for TRAC verification. The major phases of a small break LOCA observed in the OTIS tests included pressurizer draining and saturation, intermittent reactor coolant system circulation, boiler-condenser mode and the initial stages of refill. The TRAC code was successful in predicting OTIS loop conditions (system pressures and temperatures) after modification of the steam generator model. In particular, the code predicted both pool- and auxiliary- feedwater initiated boiler-condenser mode heat transfer

  15. Design studies of hydraulic verification test section of windowless target of liquid lead-bismuth eutectic experimental platform

    International Nuclear Information System (INIS)

    Zhu Linglin; Bai Yunqing; Chen Zhao

    2010-01-01

    As one of the key components of the accelerator driven system (ADS), the formation and control of the free surface is one of the key issues in the design of the windowless target which needs the theoretical analysis and experimental verification. FDS team is launching the conceptual design of ADS reactor and is developing the integrative experimental platform of liquid lead-bismuth eutectic technology. The hydraulic verification facility for windowless spallation target is an important part of the platform. In this paper, the aim of the design and major parameters of the facility were described, and the major components and experimental schemes were presented. (authors)

  16. Determination of multi-GNSS pseudo-absolute code biases and verification of receiver tracking technology

    Science.gov (United States)

    Villiger, Arturo; Schaer, Stefan; Dach, Rolf; Prange, Lars; Jäggi, Adrian

    2017-04-01

    It is common to handle code biases in the Global Navigation Satellite System (GNSS) data analysis as conventional differential code biases (DCBs): P1-C1, P1-P2, and P2-C2. Due to the increasing number of signals and systems in conjunction with various tracking modes for the different signals (as defined in RINEX3 format), the number of DCBs would increase drastically and the bookkeeping becomes almost unbearable. The Center for Orbit Determination in Europe (CODE) has thus changed its processing scheme to observable-specific signal biases (OSB). This means that for each observation involved all related satellite and receiver biases are considered. The OSB contributions from various ionosphere analyses (geometry-free linear combination) using different observables and frequencies and from clock analyses (ionosphere-free linear combination) are then combined on normal equation level. By this, one consistent set of OSB values per satellite and receiver can be obtained that contains all information needed for GNSS-related processing. This advanced procedure of code bias handling is now also applied to the IGS (International GNSS Service) MGEX (Multi-GNSS Experiment) procedure at CODE. Results for the biases from the legacy IGS solution as well as the CODE MGEX processing (considering GPS, GLONASS, Galileo, BeiDou, and QZSS) are presented. The consistency with the traditional method is confirmed and the new results are discussed regarding the long-term stability. When processing code data, it is essential to know the true observable types in order to correct for the associated biases. CODE has been verifying the receiver tracking technologies for GPS based on estimated DCB multipliers (for the RINEX 2 case). With the change to OSB, the original verification approach was extended to search for the best fitting observable types based on known OSB values. In essence, a multiplier parameter is estimated for each involved GNSS observable type. This implies that we could

  17. MAGMAsoft simulation applied in verification of technology to produce new range of alloy steel castings

    Directory of Open Access Journals (Sweden)

    A. Gwiżdż

    2010-07-01

    Full Text Available The article presents the results of MAGMAsoft application in simulation of the pouring and solidfication of castings made fromGS20Mn5 steel, basing on some principles adopted in the starting technology. The results of simulation were disclosed in the form of 3Ddrawings, showing the technology of pouring, selected stages of solidification, and porosity in castings made by the examined technology. Using simulation results, some modifications were introduced to the pouring technology, the simulation was repeated, and the results obtained for the technology before and after the modification were compared. Based on the guidelines provided in new technology, the pattern tooling was made. The process of mould preparation was described, along with the process of steel melting and pouring. Castings made by the new technology were X-rayed and subjected to heat treatment according to the newly developed cycle. Together with the main casting, test wedges were poured. Mechanical tests and structure examinations were performed. The results of the tests and investigations were evaluated.

  18. ENVIRONMENTAL TECHNOLOGY VERIFICATION JOINT (NSF-EPA) VERIFICATION STATEMENT AND REPORT, PERFORMANCE OF INDUCTION MIXERS FOR DISINFECTION OF WET WEATHER FLOWS, US FILTER/STRANCO PRODUCTS WATER CHAMP R F SERIES CHEMICAL INDUCTION SYSTEM

    Science.gov (United States)

    The Wet-Weather Flow Technologies Pilot of the EPA's Technology Verification (ETV) Program under a partnership with NSF International has verified the performawnce of the USFilter/Stranco Products chemical induction mixer used for disinfection of wet-weather flows. The USFilter t...

  19. BEval: A Plug-in to Extend Atelier B with Current Verification Technologies

    Directory of Open Access Journals (Sweden)

    Valério Medeiros Jr.

    2014-01-01

    Full Text Available This paper presents BEval, an extension of Atelier B to improve automation in the verification activities in the B method or Event-B. It combines a tool for managing and verifying software projects (Atelier B and a model checker/animator (ProB so that the verification conditions generated in the former are evaluated with the latter. In our experiments, the two main verification strategies (manual and automatic showed significant improvement as ProB's evaluator proves complementary to Atelier B built-in provers. We conducted experiments with the B model of a micro-controller instruction set; several verification conditions, that we were not able to discharge automatically or manually with AtelierB's provers, were automatically verified using BEval.

  20. Inverse transport for the verification of the Comprehensive Nuclear Test Ban Treaty

    Directory of Open Access Journals (Sweden)

    J.-P. Issartel

    2003-01-01

    Full Text Available An international monitoring system is being built as a verification tool for the Comprehensive Test Ban Treaty. Forty stations will measure on a worldwide daily basis the concentration of radioactive noble gases. The paper introduces, by handling preliminary real data, a new approach of backtracking for the identification of sources of passive tracers after positive measurements. When several measurements are available the ambiguity about possible sources is reduced significantly. The approach is validated against ETEX data. A distinction is made between adjoint and inverse transport shown to be, indeed, different though equivalent ideas. As an interesting side result it is shown that, in the passive tracer dispersion equation, the diffusion stemming from a time symmetric turbulence is necessarily a self-adjoint operator, a result easily verified for the usual gradient closure, but more general.

  1. General-purpose heat source safety verification test series: SVT-11 through SVT-13

    International Nuclear Information System (INIS)

    George, T.G.; Pavone, D.

    1986-05-01

    The General-Purpose Heat Source (GPHS) is a modular component of the radioisotope thermoelectric generator that will provide power for the Galileo and Ulysses (formerly ISPM) space missions. The GPHS provides power by transmitting the heat of 238 Pu α-decay to an array of thermoelectric elements. Because the possibility of an orbital abort always exists, the heat source was designed and constructed to minimize plutonia release in any accident environment. The Safety Verification Test (SVT) series was formulated to evaluate the effectiveness of GPHS plutonia containment after atmospheric reentry and Earth impact. The first two reports (covering SVT-1 through SVT-10) described the results of flat, side-on, and angular module impacts against steel targets at 54 m/s. This report describes flat-on module impacts against concrete and granite targets, at velocities equivalent to or higher than previous SVTs

  2. Testing the algorithms for automatic identification of errors on the measured quantities of the nuclear power plant. Verification tests

    International Nuclear Information System (INIS)

    Svatek, J.

    1999-12-01

    During the development and implementation of supporting software for the control room and emergency control centre at the Dukovany nuclear power plant it appeared necessary to validate the input quantities in order to assure operating reliability of the software tools. Therefore, the development of software for validation of the measured quantities of the plant data sources was initiated, and the software had to be debugged and verified. The report contains the proposal for and description of the verification tests for testing the algorithms of automatic identification of errors on the observed quantities of the NPP by means of homemade validation software. In particular, the algorithms treated serve the validation of the hot leg temperature at primary circuit loop no. 2 or 4 at the Dukovany-2 reactor unit using data from the URAN and VK3 information systems, recorded during 3 different days. (author)

  3. Achievement report for fiscal 1998 on the development of superconductor power application technology. 2. Research and development of superconducting wire and superconductive power generator, research of total system, research and development of refrigeration system, and verification test; 1998 nendo chodendo denryoku oyo gijutsu kaihatsu seika hokokusho. 2. Chodendo senzai no kenkyu kaihatsu, chodendo hatsudenki no kenkyu kaihatsu, total sytsem no kenkyu, reito system no kenkyu kaihatsu, jissho shiken

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    The slow excitation response type power generator is studied when the rotor and stator of a 70,000kW-class model are combinedly subjected to an on-site verification test, when a good result is obtained. The rotor is disassembled for inspection, and its members are found to be sound without any problem in terms of mechanical strength. The quick excitation response type is studied when a 70,000kW model is experimentally built and subjected to an on-site verification test after a rotation and excitation test in the factory, when the pilot machine concept design is reviewed. In the study of a total system, efforts continue for the review of the model machine test method, improvement on generator design and analytical methods, development of operating methods, and the effect of its introduction into the power system. Since a He-refrigerated system is requested to exhibit high reliability for application to power equipment and to be capable of continuous long-period operation, a system having constituents with their reliability enhanced and an appropriate redundant system is developed, and a verification study is under way which will continue for more than 10,000 hours. Described also is an oil-free low-temperature turbo refrigerator. The latest quick excitation response type rotor is also tested for verification. (NEDO)

  4. The verification tests of residual radioactivity measurement and assessment techniques for buildings and soils

    International Nuclear Information System (INIS)

    Onozawa, T.; Ishikura, T.; Yoshimura, Yukio; Nakazawa, M.; Makino, S.; Urayama, K.; Kawasaki, S.

    1996-01-01

    According to the standard procedure for decommissioning a commercial nuclear power plant (CNPP) in Japan, controlled areas will be released for unrestricted use before the dismantling of a reactor building. If manual survey and sampling techniques were applied to measurement for unrestricted release on and in the extensive surface of the building, much time and much specialized labor would be required to assess the appropriateness of the releasing. Therefore the authors selected the following three techniques for demonstrating reliability and applicability of the techniques for CNPPs: (1) technique of assessing radioactive concentration distribution on the surface of buildings (ADB); (2) technique of assessing radioactive permeation distribution in the concrete structure of buildings (APB); (3) technique of assessing radioactive concentration distribution in soil (ADS). These tests include the techniques of measuring and assessing very low radioactive concentration distribution on the extensive surfaces of buildings and the soil surrounding of a plant with automatic devices. Technical investigation and preliminary study of the verification tests were started in 1990. In the study, preconditions were clarified for each technique and the performance requirements were set up. Moreover, simulation models have been constructed for several feasible measurement method to assess their performance in terms of both measurement test and simulation analysis. Fundamental tests have been under way using small-scale apparatuses since 1994

  5. Verification test of the SURF and SURFplus models in xRage

    Energy Technology Data Exchange (ETDEWEB)

    Menikoff, Ralph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-05-18

    As a verification test of the SURF and SURFplus models in the xRage code we use a propagating underdriven detonation wave in 1-D. This is about the only test cases for which an accurate solution can be determined based on the theoretical structure of the solution. The solution consists of a steady ZND reaction zone profile joined with a scale invariant rarefaction or Taylor wave and followed by a constant state. The end of the reaction profile and the head of the rarefaction coincide with the sonic CJ state of the detonation wave. The constant state is required to match a rigid wall boundary condition. For a test case, we use PBX 9502 with the same EOS and burn rate as previously used to test the shock detector algorithm utilized by the SURF model. The detonation wave is propagated for 10 μs (slightly under 80mm). As expected, the pointwise errors are largest in the neighborhood of discontinuities; pressure discontinuity at the lead shock front and pressure derivative discontinuities at the head and tail of the rarefaction. As a quantitative measure of the overall accuracy, the L2 norm of the difference of the numerical pressure and the exact solution is used. Results are presented for simulations using both a uniform grid and an adaptive grid that refines the reaction zone.

  6. Achievement report for fiscal 1996 on the research and development of superconductor technology to power generation. Pt. 1. Research and development of superconducting wire, generator, total system, and refrigeration system; and verification test; 1996 nendo chodendo denryoku oyo gijutsu kaihatsu seika hokokusho. 1. Chodendo senzai no kenkyu kaihatsu, chodendo hatsudenki no kenkyu kaihatsu, total system no kenkyu, reito system no kenkyu kaihatsu, jissho shiken

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-01

    In the research and development of superconducting wires, studies are conducted to increase the current capacity of NbTi and Nb{sub 3}Sn metal wires and to improve their properties, and to increase the current capacity of oxide materials and improve their performance making full use of the features of each manufacturing method. In the development of superconducting generators, a slow excitation response type is tested for verification, and a good result is attained; and a quick excitation response type is tested for field winding static excitation, and good performance is exhibited. Using the results so far achieved, the 200,000kW class pilot machine concept design is reviewed. In the study of total systems, feasibility is studied of a quench test for the 70,000kW class machine through simulation analyses, etc. In the development of refrigeration systems, efforts are exerted to improve on the conventional type in terms of reliability and to further improve on the improved version in terms of performance and space-saving feature. One of the endeavors involves the development of a He Brayton cycle turbine driven compressor. A multilayer cylindrical rotor is verified in terms of functions, characteristics, reliability and durability, and various data are collected toward the development of a pilot machine. (NEDO)

  7. Material integrity verification radar

    International Nuclear Information System (INIS)

    Koppenjan, S.K.

    1999-01-01

    The International Atomic Energy Agency (IAEA) has the need for verification of 'as-built' spent fuel-dry storage containers and other concrete structures. The IAEA has tasked the Special Technologies Laboratory (STL) to fabricate, test, and deploy a stepped-frequency Material Integrity Verification Radar (MIVR) system to nondestructively verify the internal construction of these containers. The MIVR system is based on previously deployed high-frequency, ground penetrating radar (GPR) systems that have been developed by STL for the U.S. Department of Energy (DOE). Whereas GPR technology utilizes microwave radio frequency energy to create subsurface images, MTVR is a variation for which the medium is concrete instead of soil. The purpose is to nondestructively verify the placement of concrete-reinforcing materials, pipes, inner liners, and other attributes of the internal construction. The MIVR system underwent an initial field test on CANDU reactor spent fuel storage canisters at Atomic Energy of Canada Limited (AECL), Chalk River Laboratories, Ontario, Canada, in October 1995. A second field test at the Embalse Nuclear Power Plant in Embalse, Argentina, was completed in May 1996. The DOE GPR also was demonstrated at the site. Data collection and analysis were performed for the Argentine National Board of Nuclear Regulation (ENREN). IAEA and the Brazilian-Argentine Agency for the Control and Accounting of Nuclear Material (ABACC) personnel were present as observers during the test. Reinforcing materials were evident in the color, two-dimensional images produced by the MIVR system. A continuous pattern of reinforcing bars was evident and accurate estimates on the spacing, depth, and size were made. The potential uses for safeguard applications were jointly discussed. The MIVR system, as successfully demonstrated in the two field tests, can be used as a design verification tool for IAEA safeguards. A deployment of MIVR for Design Information Questionnaire (DIQ

  8. 78 FR 33132 - Quality Verification for Plate-Type Uranium-Aluminum Fuel Elements for Use in Research and Test...

    Science.gov (United States)

    2013-06-03

    ... Fuel Elements for Use in Research and Test Reactors AGENCY: Nuclear Regulatory Commission. ACTION... Regulatory Guide (RG) 2.3, ``Quality Verification for Plate-Type Uranium-Aluminum Fuel Elements for Use in... assurance program for verifying the quality of plate-type uranium-aluminum fuel elements used in research...

  9. SRS environmental technology development field test platform

    International Nuclear Information System (INIS)

    Riha, B.D.; Rossabi, J.; Eddy-Dilek, C.A.

    1995-01-01

    A critical and difficult step in the development and implementation of new technologies for environmental monitoring and characterization is successfully transferring these technologies to industry and government users for routine assessment and compliance activities. The Environmental Sciences Section of the DOE Savannah River Technology Center provides a forum for developers, potential users, and regulatory organizations to evaluate new technologies in comparison with baseline technologies in a well characterized field test bed. The principal objective of this project is to conduct comprehensive, objective field tests of monitoring and characterization technologies that are not currently used in EPA standard methods and evaluate their performance during actual operating conditions against baseline methods. This paper provides an overview of the field test site and a description of some of the technologies demonstrated at the site including their field applications

  10. AXAF-I Low Intensity-Low Temperature (LILT) Testing of the Development Verification Test (DVT) Solar Panel

    Science.gov (United States)

    Alexander, Doug; Edge, Ted; Willowby, Doug

    1998-01-01

    The planned orbit of the AXAF-I spacecraft will subject the spacecraft to both short, less than 30 minutes for solar and less than 2 hours for lunar, and long earth eclipses and lunar eclipses with combined conjunctive duration of up to 3 to 4 hours. Lack of proper Electrical Power System (EPS) conditioning prior to eclipse may cause loss of mission. To avoid this problem, for short eclipses, it is necessary to off-point the solar array prior to or at the beginning of the eclipse to reduce the battery state of charge (SOC). This yields less overcharge during the high charge currents at sun entry. For long lunar eclipses, solar array pointing and load scheduling must be tailored for the profile of the eclipse. The battery SOC, loads, and solar array current-voltage (I-V) must be known or predictable to maintain the bus voltage within acceptable range. To address engineering concerns about the electrical performance of the AXAF-I solar array under Low Intensity and Low Temperature (LILT) conditions, Marshall Space Flight Center (MSFC) engineers undertook special testing of the AXAF-I Development Verification Test (DVT) solar panel in September-November 1997. In the test the DVT test panel was installed in a thermal vacuum chamber with a large view window with a mechanical "flapper door". The DVT test panel was "flash" tested with a Large Area Pulse Solar Simulator (LAPSS) at various fractional sun intensities and panel (solar cell) temperatures. The testing was unique with regards to the large size of the test article and type of testing performed. The test setup, results, and lessons learned from the testing will be presented.

  11. Translational Environmental Science and Technology (TEST)

    African Journals Online (AJOL)

    TUOYO

    Hence “translational environmental science and technology (TEST)” could be a formal representation of the new emphasis captured as “laboratory bench –to– ecosystem –to– sustainability.” This is arguably a more robust conceptual framework than “technology transfer.” The articulation of TEST as an operative framework ...

  12. Verification testing of the compression performance of the HEVC screen content coding extensions

    Science.gov (United States)

    Sullivan, Gary J.; Baroncini, Vittorio A.; Yu, Haoping; Joshi, Rajan L.; Liu, Shan; Xiu, Xiaoyu; Xu, Jizheng

    2017-09-01

    This paper reports on verification testing of the coding performance of the screen content coding (SCC) extensions of the High Efficiency Video Coding (HEVC) standard (Rec. ITU-T H.265 | ISO/IEC 23008-2 MPEG-H Part 2). The coding performance of HEVC screen content model (SCM) reference software is compared with that of the HEVC test model (HM) without the SCC extensions, as well as with the Advanced Video Coding (AVC) joint model (JM) reference software, for both lossy and mathematically lossless compression using All-Intra (AI), Random Access (RA), and Lowdelay B (LB) encoding structures and using similar encoding techniques. Video test sequences in 1920×1080 RGB 4:4:4, YCbCr 4:4:4, and YCbCr 4:2:0 colour sampling formats with 8 bits per sample are tested in two categories: "text and graphics with motion" (TGM) and "mixed" content. For lossless coding, the encodings are evaluated in terms of relative bit-rate savings. For lossy compression, subjective testing was conducted at 4 quality levels for each coding case, and the test results are presented through mean opinion score (MOS) curves. The relative coding performance is also evaluated in terms of Bjøntegaard-delta (BD) bit-rate savings for equal PSNR quality. The perceptual tests and objective metric measurements show a very substantial benefit in coding efficiency for the SCC extensions, and provided consistent results with a high degree of confidence. For TGM video, the estimated bit-rate savings ranged from 60-90% relative to the JM and 40-80% relative to the HM, depending on the AI/RA/LB configuration category and colour sampling format.

  13. Measuring Software Test Verification for Complex Workpieces based on Virtual Gear Measuring Instrument

    Science.gov (United States)

    Yin, Peili; Wang, Jianhua; Lu, Chunxia

    2017-08-01

    Validity and correctness test verification of the measuring software has been a thorny issue hindering the development of Gear Measuring Instrument (GMI). The main reason is that the software itself is difficult to separate from the rest of the measurement system for independent evaluation. This paper presents a Virtual Gear Measuring Instrument (VGMI) to independently validate the measuring software. The triangular patch model with accurately controlled precision was taken as the virtual workpiece and a universal collision detection model was established. The whole process simulation of workpiece measurement is implemented by VGMI replacing GMI and the measuring software is tested in the proposed virtual environment. Taking involute profile measurement procedure as an example, the validity of the software is evaluated based on the simulation results; meanwhile, experiments using the same measuring software are carried out on the involute master in a GMI. The experiment results indicate a consistency of tooth profile deviation and calibration results, thus verifying the accuracy of gear measuring system which includes the measurement procedures. It is shown that the VGMI presented can be applied in the validation of measuring software, providing a new ideal platform for testing of complex workpiece-measuring software without calibrated artifacts.

  14. The USP Performance Verification Test, Part II: collaborative study of USP's Lot P Prednisone Tablets.

    Science.gov (United States)

    Glasgow, Maria; Dressman, Shawn; Brown, William; Foster, Thomas; Schuber, Stefan; Manning, Ronald G; Wahab, Samir Z; Williams, Roger L; Hauck, Walter W

    2008-05-01

    Periodic performance verification testing (PVT) is used by laboratories to assess and demonstrate proficiency and for other purposes as well. For dissolution, the PVT is specified in the US Pharmacopeia General Chapter Dissolution under the title Apparatus Suitability Test. For Apparatus 1 and 2, USP provides two reference standard tablets for this purpose. For each new lot of these reference standards, USP conducts a collaborative study. For new USP Lot P Prednisone Tablets, 28 collaborating laboratories provided data. The study was conducted with three sets of tablets: Lot O open label, Lot O blinded, and Lot P blinded. The blinded Lot O data were used for apparatus suitability testing. Acceptance limits were determined after dropping data due to failure of apparatus suitability, identification of data as unusual on control charts, or protocol violations. Results yielded acceptance criteria of (47, 82) for Apparatus 1 and (37, 70) for Apparatus 2. Results generally were similar for Lot P compared to results from Lot O except that the average percent dissolved for Lot P is greater than for Lot O with Apparatus 2.

  15. Measuring Software Test Verification for Complex Workpieces based on Virtual Gear Measuring Instrument

    Directory of Open Access Journals (Sweden)

    Yin Peili

    2017-08-01

    Full Text Available Validity and correctness test verification of the measuring software has been a thorny issue hindering the development of Gear Measuring Instrument (GMI. The main reason is that the software itself is difficult to separate from the rest of the measurement system for independent evaluation. This paper presents a Virtual Gear Measuring Instrument (VGMI to independently validate the measuring software. The triangular patch model with accurately controlled precision was taken as the virtual workpiece and a universal collision detection model was established. The whole process simulation of workpiece measurement is implemented by VGMI replacing GMI and the measuring software is tested in the proposed virtual environment. Taking involute profile measurement procedure as an example, the validity of the software is evaluated based on the simulation results; meanwhile, experiments using the same measuring software are carried out on the involute master in a GMI. The experiment results indicate a consistency of tooth profile deviation and calibration results, thus verifying the accuracy of gear measuring system which includes the measurement procedures. It is shown that the VGMI presented can be applied in the validation of measuring software, providing a new ideal platform for testing of complex workpiece-measuring software without calibrated artifacts.

  16. Case Study: Test Results of a Tool and Method for In-Flight, Adaptive Control System Verification on a NASA F-15 Flight Research Aircraft

    Science.gov (United States)

    Jacklin, Stephen A.; Schumann, Johann; Guenther, Kurt; Bosworth, John

    2006-01-01

    Adaptive control technologies that incorporate learning algorithms have been proposed to enable autonomous flight control and to maintain vehicle performance in the face of unknown, changing, or poorly defined operating environments [1-2]. At the present time, however, it is unknown how adaptive algorithms can be routinely verified, validated, and certified for use in safety-critical applications. Rigorous methods for adaptive software verification end validation must be developed to ensure that. the control software functions as required and is highly safe and reliable. A large gap appears to exist between the point at which control system designers feel the verification process is complete, and when FAA certification officials agree it is complete. Certification of adaptive flight control software verification is complicated by the use of learning algorithms (e.g., neural networks) and degrees of system non-determinism. Of course, analytical efforts must be made in the verification process to place guarantees on learning algorithm stability, rate of convergence, and convergence accuracy. However, to satisfy FAA certification requirements, it must be demonstrated that the adaptive flight control system is also able to fail and still allow the aircraft to be flown safely or to land, while at the same time providing a means of crew notification of the (impending) failure. It was for this purpose that the NASA Ames Confidence Tool was developed [3]. This paper presents the Confidence Tool as a means of providing in-flight software assurance monitoring of an adaptive flight control system. The paper will present the data obtained from flight testing the tool on a specially modified F-15 aircraft designed to simulate loss of flight control faces.

  17. A two-dimensional liquid-filled ionization chamber array prototype for small-field verification: characterization and first clinical tests

    Science.gov (United States)

    Brualla-González, Luis; Gómez, Faustino; Vicedo, Aurora; González-Castaño, Diego M.; Gago-Arias, Araceli; Pazos, Antonio; Zapata, Martín; Roselló, Joan V.; Pardo-Montero, Juan

    2012-08-01

    In this work we present the design, characterization and first clinical tests of an in-house developed two-dimensional liquid-filled ionization chamber prototype for the verification of small radiotherapy fields and treatments containing such small fields as in radiosurgery, which consists of 2 mm × 2 mm pixels arranged on a 16×8 rectangular grid. The ionization medium is isooctane. The characterization of the device included the study of depth, field-size and dose-rate dependences, which are sufficiently moderate for a good operation at therapy radiation levels. However, the detector presents an important anisotropic response, up to ≃ 12% for front versus near-lateral incidence, which can impact the verification of full treatments with different incidences. In such a case, an anisotropy correction factor can be applied. Output factors of small square fields measured with the device show a small systematic over-response, less than 1%, when compared to unshielded diode measurements. An IMRT radiosurgery treatment has been acquired with the liquid-filled ionization chamber device and compared with film dosimetry by using the gamma method, showing good agreement: over 99% passing rates for 1.2% and 1.2 mm for an incidence-per-incidence analysis; 100% passing rates for tolerances 1.8% and 1.8 mm when the whole treatment is analysed and the anisotropy correction factor is applied. The point dose verification for each incidence of the treatment performed with the liquid-filled ionization chamber agrees within 1% with a CC01 ionization chamber. This prototype has shown the utility of this kind of technology for the verification of small fields/treatments. Currently, a larger device covering a 5 cm × 5 cm area is under development.

  18. Structural identification of short/middle span bridges by rapid impact testing: theory and verification

    Science.gov (United States)

    Zhang, Jian; Zhang, Q. Q.; Guo, S. L.; Xu, D. W.; Wu, Z. S.

    2015-06-01

    A structural strain flexibility identification method by processing the multiple-reference impact testing data is proposed. First, a kind of novel long-gauge fiber optic sensor is developed for structural macro-strain monitoring. Second, the multiple-reference impact testing technology is employed, during which both the impacting force and structural strain responses are measured. The impact testing technology has unique merit because it is able to extract exact structural frequency response functions (FRFs), while other test methods, for instance ambient tests, can only output the FRFs with scaled magnitudes. Most importantly, the originality of the article is that a method of identifying the structural strain flexibility characteristic from the impact test data has been proposed, which is useful for structural static strain prediction and capacity evaluation. Examples of a six meter simple supported beam and a multiple-span continuous beam bridge have successfully verified the effectiveness of the proposed method.

  19. Electromagnetic compatibility (EMC) standard test chamber upgrade requirements for spacecraft design verification tests

    Science.gov (United States)

    Dyer, Edward F.

    1992-01-01

    In view of the serious performance deficiencies inherent in conventional modular and welded shielding EMC test enclosures, in which multipath reflections and resonant standing waves can damage flight hardware during RF susceptibility tests, NASA-Goddard has undertaken the modification of a 20 x 24 ft modular-shielded enclosure through installation of steel panels to which ferrite tiles will be mounted with epoxy. The internally reflected RF energy will thereby be absorbed, and exterior power-line noise will be reduced. Isolation of power-line filters and control of 60-Hz ground connections will also be undertaken in the course of upgrading.

  20. System and Component Software Specification, Run-time Verification and Automatic Test Generation, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposal is for the creation of a system-level software specification and verification tool. This proposal suggests a major leap-forward in usability of...

  1. Empirical Tests and Preliminary Results with the Krakatoa Tool for Full Static Program Verification

    OpenAIRE

    Ramírez-de León Edgar Darío; Chávez-Bosquez Oscar; Francisco-León Julián Javier

    2014-01-01

    XJML (Ramírez et al., 2012) is a modular external platform for Verification and Validation of Java classes using the Java Modeling Language (JML) through contracts written in XML. One problem faced in the XJML development was how to integrate Full Static Program Verification (FSPV). This paper presents the experiments and results that allowed us to define what tool to embed in XJML to execute FSPV.

  2. Empirical Tests and Preliminary Results with the Krakatoa Tool for Full Static Program Verification

    Directory of Open Access Journals (Sweden)

    Ramírez-de León Edgar Darío

    2014-10-01

    Full Text Available XJML (Ramírez et al., 2012 is a modular external platform for Verification and Validation of Java classes using the Java Modeling Language (JML through contracts written in XML. One problem faced in the XJML development was how to integrate Full Static Program Verification (FSPV. This paper presents the experiments and results that allowed us to define what tool to embed in XJML to execute FSPV.

  3. Research of laser stealth performance test technology

    Science.gov (United States)

    Chen, Zhen-xing; Shi, Sheng-bing; Han, Fu-li; Wu, Yan-lin; Song, Chun-yan

    2014-09-01

    Laser stealth is an important way of photoelectric stealth weapons systems. According to operational principle of laser range finder, we actively explore and study the stealth performance approval testing technology of laser stealth materials, and bring forward and establish the stealth performance field test methods of stealth efficiency evaluation. Through contrastive test of two kinds of materials, the method is correct and effective.

  4. Validation and Verification (V and V) Testing on Midscale Flame Resistant (FR) Test Method

    Science.gov (United States)

    2016-12-16

    person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control ...roughly equally over the body surface, excluding the hands and feet. The F1930 test method requires a minimum of 100 sensors [1]. If copper slug ...copper slug . In fact, though a large number of sensors is employed, a comparison with the total sensor area with typical numbers for body surface area

  5. Development and verification test of integral reactor major components - Development of MCP impeller design, performance prediction code and experimental verification

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Myung Kyoon; Oh, Woo Hyoung; Song, Jae Wook [Korea Advanced Institute of Science and Technology, Taejon (Korea)

    1999-03-01

    The present study is aimed at developing a computational code for design and performance prediction of an axial-flow pump. The proposed performance prediction method is tested against a model axial-flow pump streamline curvature method. The preliminary design is made by using the ideal velocity triangles at inlet and exit and the three dimensional blade shape is calculated by employing the free vortex design method. Then the detailed blading design is carried out by using experimental database of double circular arc cambered hydrofoils. To computationally determine the design incidence, deviation, blade camber, solidity and stagger angle, a number of correlation equations are developed form the experimental database and a theorical formula for the lift coefficient is adopted. A total of 8 equations are solved iteratively using an under-relaxation factor. An experimental measurement is conducted under a non-cavitating condition to obtain the off-design performance curve and also a cavitation test is carried out by reducing the suction pressure. The experimental results are very satisfactorily compared with the predictions by the streamline curvature method. 28 refs., 26 figs., 11 tabs. (Author)

  6. Transport Network Technologies – Study and Testing

    DEFF Research Database (Denmark)

    Bozorgebrahimi, K.; Channegowda, M.; Colmenero, A.

    Following on from the theoretical research into Carrier Class Transport Network Technologies (CCTNTs) documented in DJ1.1.1, this report describes the extensive testing performed by JRA1 Task 1. The tests covered EoMPLS, Ethernet OAM, Synchronous Ethernet, PBB-TE, MPLS-TP, OTN and GMPLS, and the ......Following on from the theoretical research into Carrier Class Transport Network Technologies (CCTNTs) documented in DJ1.1.1, this report describes the extensive testing performed by JRA1 Task 1. The tests covered EoMPLS, Ethernet OAM, Synchronous Ethernet, PBB-TE, MPLS-TP, OTN and GMPLS...

  7. Microelectronic test structures for CMOS technology

    CERN Document Server

    Ketchen, Mark B

    2011-01-01

    Microelectronic Test Structures for CMOS Technology and Products addresses the basic concepts of the design of test structures for incorporation within test-vehicles, scribe-lines, and CMOS products. The role of test structures in the development and monitoring of CMOS technologies and products has become ever more important with the increased cost and complexity of development and manufacturing. In this timely volume, IBM scientists Manjul Bhushan and Mark Ketchen emphasize high speed characterization techniques for digital CMOS circuit applications and bridging between circuit performance an

  8. Verification test of advanced LWR fuel components of Westinghouse type nuclear power plants

    International Nuclear Information System (INIS)

    Kim, Hyung Kyu; Yoon, Kyung Ho; Lee, Young Ho

    2004-08-01

    The purpose of this project is to independently conduct the performance test of the spacer grids and the cladding material of the 16x16 and 17x17 advanced fuels for Westinghouse type plants, and to improve the relevant test technology. Major works and results of the present research are as follows. 1. The design and structural features of the spacer grids were investigated, especially the finally determined I-spring was thoroughly analyzed in the point of the mechanical damage and characteristic. 2. As for the mechanical tests of the space grids, the characterization, the impact and the fretting wear tests were carried out. The block as well as the in-grid tests were conducted for the spring/dimple characterization, from which a simple method was developed that simulated the boundary conditions of the assembled grid straps. The impact tester was modified and improved to accommodate a full size grid assembly. The impact result showed that the grid assembly fulfilled the design criteria. As for the fretting wear tests, a sliding test under the room temperature air/water, a sliding/impact test under the room temperature air and a sliding/impact tests under the high temperature and pressure environments were carried out. To this end, a high temperature and pressure fretting wear tester was newly developed. The wear characteristic and the resistibility of the advanced grid spring/dimple were analyzed in detail. The test results were verified through comparing those with the test results by the Westinghouse company. 3. The properties and performance of the newly adopted material for the cladding, Low Sn Zirlo was investigated by a room and high temperature tensile tests and a corrosion tests under the environments of 360 .deg. C water, 400 steam and 360 .deg. C 70ppm LiOH. Through the present project, all the test equipment and technologies for the fuel components were procured, which will be used for future domestic development of a new fuel

  9. Some New Verification Test Problems for Multimaterial Diffusion on Meshes that are Non-Aligned with Material Boundaries

    Energy Technology Data Exchange (ETDEWEB)

    Dawes, Alan Sidney [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Malone, Christopher M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Shashkov, Mikhail Jurievich [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-07-07

    In this report a number of new verification test problems for multimaterial diffusion will be shown. Using them we will show that homogenization of multimaterial cells in either Arbitrary Lagrangian Eulerian (ALE) or Eulerian simulations can lead to errors in the energy flow at the interfaces. Results will be presented that show that significant improvements and predictive capability can be gained by using either a surrogate supermesh, such as Thin Mesh in FLAG, or the emerging method based on Static Condensation.

  10. Pathfinder Technology Demonstrator: GlobalStar Testing and Results

    Science.gov (United States)

    Kuroda, Vanessa; Limes, Gregory L.; Han, Shi Lei; Hanson, John Eric; Christa, Scott E.

    2016-01-01

    The communications subsystem of a spacecraft is typically a SWaP (size, weight, and power) intensive subsystem in a SWaP constrained environment such as a CubeSat. Use of a satellite-based communication system, such as GlobalStars duplex GSP-1720 radio is a low SWaP potentially game-changing low-cost communication subsystem solution that was evaluated for feasibility for the NASA Pathfinder Technology Demonstrator (PTD) project. The PTD project is a series of 6U CubeSat missions to flight demonstrate and characterize novel small satellite payloads in low Earth orbit. GlobalStar is a low Earth orbit satellite constellation for satellite phone and low-speed data communications, and the GSP-1720 is their single board duplex radio most commonly used in satellite phones and shipment tracking devices. The PTD project tested the GSP-1720 to characterize its viability for flight using NASA GEVS (General Environmental Verification Standard) vibration and thermal vacuum levels, as well as testing the uplink-downlink connectivity, data throughput, and file transfer capabilities. This presentation will present the results of the environmental and capability testing of the GSP-1720 performed at NASA Ames Research Center, as well as the viability for CubeSat use in LEO.

  11. Achievement of VO2max criteria during a continuous graded exercise test and a verification stage performed by college athletes.

    Science.gov (United States)

    Mier, Constance M; Alexander, Ryan P; Mageean, Amanda L

    2012-10-01

    The purpose of this study was to determine the incidence of meeting specific VO2max criteria and to test the effectiveness of a VO2max verification stage in college athletes. Thirty-five subjects completed a continuous graded exercise test (GXT) to volitional exhaustion. The frequency of achieving various respiratory exchange ratio (RER) and age-predicted maximum heart rate (HRmax) criteria and a VO2 plateau within 2 and 2.2 ml·kg(-1)·min(-1) (active recovery, 10 subjects who did not demonstrate a plateau completed a verification stage performed at supramaximal intensity. From the GXT, the number of subjects meeting VO2max plateau was 5 (≤2 ml·kg(-1)·min(-1)) and 7 (≤2.2 ml·kg(-1)·min(-1)), RER criteria 34 (≥1.05), 32 (≥1.10), and 24 (≥1.15), HRmax criteria, 35 (athlete's ability to achieve VO2max plateau and certain RER and HR criteria. The use of a verification stage increases the frequency of VO2max achievement and may be an effective method to improve the accuracy of VO2max measurements in college athletes.

  12. 9 CFR 310.25 - Contamination with microorganisms; process control verification criteria and testing; pathogen...

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Contamination with microorganisms... CERTIFICATION POST-MORTEM INSPECTION § 310.25 Contamination with microorganisms; process control verification... controls sufficient to prevent fecal contamination. FSIS shall take further action as appropriate to ensure...

  13. Current Status of Aerosol Generation and Measurement Facilities for the Verification Test of Containment Filtered Venting System in KAERI

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Il; An, Sang Mo; Ha, Kwang Soon; Kim, Hwan Yeol [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    In this study, the design of aerosol generation and measurement systems are explained and present circumstances are also described. In addition, the aerosol test plan is shown. Containment Filtered Venting System (FCVS) is one of the safety features to reduce the amount of released fission product into the environment by depressurizing the containment. Since Chernobyl accident, the regulatory agency in several countries in Europe such as France, Germany, Sweden, etc. have been demanded the installation of the CFVS. Moreover, the feasibility study on the CFVS was also performed in U.S. After the Fukushima accident, there is a need to improve a containment venting or installation of depressurizing facility in Korea. As a part of a Ministry of Trade, Industry and Energy (MOTIE) project, KAERI has been conducted the integrated performance verification test of CFVS. As a part of the test, aerosol generation system and measurement systems were designed to simulate the fission products behavior. To perform the integrated verification test of CFVS, aerosol generation and measurement system was designed and manufactured. The component operating condition is determined to consider the severe accident condition. The test will be performed in normal conditions at first, and will be conducted under severe condition, high pressure and high temperature. Undesirable difficulties which disturb the elaborate test are expected, such as thermophoresis on the pipe, vapor condensation on aerosol, etc.

  14. Verification test for three WindCube WLS7 LiDARs at the Høvsøre test site

    DEFF Research Database (Denmark)

    Gottschall, Julia; Courtney, Michael

    The report describes the procedure of testing ground-based WindCube lidars (manufactured by the French company Leosphere) at the Høvsøre test site in comparison to reference sensors mounted at a meteorological mast. Results are presented for three tested units – in detail for unit WLS7......-0062, and in a summary for units WLS7-0064 and WLS7-0066. The verification test covers the evaluation of measured mean wind speeds, wind directions and wind speed standard deviations. The data analysis is basically performed in terms of different kinds of regression analyses....

  15. Knowledge Based Systems (KBS) Verification, Validation, Evaluation, and Testing (VVE&T) Bibliography: Topical Categorization

    Science.gov (United States)

    2003-03-01

    Informatics, Universitat de Les Illes Balears , France, July 1994. [11, 14] Knowledge Base Reduction Ginsberg, A., "Knowledge-Base Reduction: A New...Bayberry Street 4000 Central Florida Blvd. Oak Park CA 91301 Orlando FL 32816 3 Technische Universitat Ilmenau 98693 Ilmenau Germany 9. SPONSORING...P., Verification of Multi-Level Rule-Based Expert Systems, Ph.D. Dissertation, Universitat Politecnica de Catalunya, Spain, April 1992. [14] IRS-CBR

  16. Reliability test for reactor internals rejuvenation technology

    International Nuclear Information System (INIS)

    Uchiyama, Junichi

    1998-01-01

    41 transparencies were presented on the subject of 'Reliability test for reactor internals rejuvenation technology'. The items presented give an introduction on the management of plant life in Japan and introduce the Nuclear Power Engineering Corporation (NUPEC). The question of what reliability tests for rejuvenation of reactor internals are is discussed in some detail and an outline of each test is given. Altogether six methods to rejuvenate reactor internals are presented, two of which have already been applied to actual plants. The presentation was supported by many detailed drawings and images

  17. Measurement of a True [Formula: see text]O2max during a Ramp Incremental Test Is Not Confirmed by a Verification Phase.

    Science.gov (United States)

    Murias, Juan M; Pogliaghi, Silvia; Paterson, Donald H

    2018-01-01

    The accuracy of an exhaustive ramp incremental (RI) test to determine maximal oxygen uptake ([Formula: see text]O 2max ) was recently questioned and the utilization of a verification phase proposed as a gold standard. This study compared the oxygen uptake ([Formula: see text]O 2 ) during a RI test to that obtained during a verification phase aimed to confirm attainment of [Formula: see text]O 2max . Sixty-one healthy males [31 older (O) 65 ± 5 yrs; 30 younger (Y) 25 ± 4 yrs] performed a RI test (15-20 W/min for O and 25 W/min for Y). At the end of the RI test, a 5-min recovery period was followed by a verification phase of constant load cycling to fatigue at either 85% ( n = 16) or 105% ( n = 45) of the peak power output obtained from the RI test. The highest [Formula: see text]O 2 after the RI test (39.8 ± 11.5 mL·kg -1 ·min -1 ) and the verification phase (40.1 ± 11.2 mL·kg -1 ·min -1 ) were not different ( p = 0.33) and they were highly correlated ( r = 0.99; p see text]O 2max derived from a RI test, in a large and heterogeneous group of healthy younger and older men naïve to laboratory testing procedures. Moreover, only minor within-individual differences were observed between the maximal [Formula: see text]O 2 elicited during the RI and the verification phase. Thus a verification phase does not add any validation of the determination of a [Formula: see text]O 2max . Therefore, the recommendation that a verification phase should become a gold standard procedure, although initially appealing, is not supported by the experimental data.

  18. Historical hydronuclear testing: Characterization and remediation technologies

    Energy Technology Data Exchange (ETDEWEB)

    Shaulis, L.; Wilson, G.; Jacobson, R.

    1997-09-01

    This report examines the most current literature and information available on characterization and remediation technologies that could be used on the Nevada Test Site (NTS) historical hydronuclear test areas. Historical hydronuclear tests use high explosives and a small amount of plutonium. The explosion scatters plutonium within a contained subsurface environment. There is currently a need to characterize these test areas to determine the spatial extent of plutonium in the subsurface and whether geohydrologic processes are transporting the plutonium away from the event site. Three technologies were identified to assist in the characterization of the sites. These technologies are the Pipe Explorer{trademark}, cone penetrometer, and drilling. If the characterization results indicate that remediation is needed, three remediation technologies were identified that should be appropriate, namely: capping or sealing the surface, in situ grouting, and in situ vitrification. Capping the surface would prevent vertical infiltration of water into the soil column, but would not restrict lateral movement of vadose zone water. Both the in situ grouting and vitrification techniques would attempt to immobilize the radioactive contaminants to restrict or prevent leaching of the radioactive contaminants into the groundwater. In situ grouting uses penetrometers or boreholes to inject the soil below the contaminant zone with low permeability grout. In situ vitrification melts the soil containing contaminants into a solid block. This technique would provide a significantly longer contaminant immobilization, but some research and development would be required to re-engineer existing systems for use at deep soil depths. Currently, equipment can only handle shallow depth vitrification. After existing documentation on the historical hydronuclear tests have been reviewed and the sites have been visited, more specific recommendations will be made.

  19. Historical hydronuclear testing: Characterization and remediation technologies

    International Nuclear Information System (INIS)

    Shaulis, L.; Wilson, G.; Jacobson, R.

    1997-09-01

    This report examines the most current literature and information available on characterization and remediation technologies that could be used on the Nevada Test Site (NTS) historical hydronuclear test areas. Historical hydronuclear tests use high explosives and a small amount of plutonium. The explosion scatters plutonium within a contained subsurface environment. There is currently a need to characterize these test areas to determine the spatial extent of plutonium in the subsurface and whether geohydrologic processes are transporting the plutonium away from the event site. Three technologies were identified to assist in the characterization of the sites. These technologies are the Pipe Explorer trademark, cone penetrometer, and drilling. If the characterization results indicate that remediation is needed, three remediation technologies were identified that should be appropriate, namely: capping or sealing the surface, in situ grouting, and in situ vitrification. Capping the surface would prevent vertical infiltration of water into the soil column, but would not restrict lateral movement of vadose zone water. Both the in situ grouting and vitrification techniques would attempt to immobilize the radioactive contaminants to restrict or prevent leaching of the radioactive contaminants into the groundwater. In situ grouting uses penetrometers or boreholes to inject the soil below the contaminant zone with low permeability grout. In situ vitrification melts the soil containing contaminants into a solid block. This technique would provide a significantly longer contaminant immobilization, but some research and development would be required to re-engineer existing systems for use at deep soil depths. Currently, equipment can only handle shallow depth vitrification. After existing documentation on the historical hydronuclear tests have been reviewed and the sites have been visited, more specific recommendations will be made

  20. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, REMOVAL OF ARSENIC IN DRINKING WATER: WATTS PREMIER M-SERIES M-15,000 REVERSE OSMOSIS TREATMENT SYSTEM

    Science.gov (United States)

    Verification testing of the Watts Premier M-Series M-15,000 RO Treatment System was conducted over a 31-day period from April 26, 2004, through May 26, 2004. This test was conducted at the Coachella Valley Water District (CVWD) Well 7802 in Thermal, California. The source water...

  1. Optimized periodic verification testing blended risk and performance-based MOV inservice test program an application of ASME code case OMN-1

    Energy Technology Data Exchange (ETDEWEB)

    Sellers, C.; Fleming, K.; Bidwell, D.; Forbes, P. [and others

    1996-12-01

    This paper presents an application of ASME Code Case OMN-1 to the GL 89-10 Program at the South Texas Project Electric Generating Station (STPEGS). Code Case OMN-1 provides guidance for a performance-based MOV inservice test program that can be used for periodic verification testing and allows consideration of risk insights. Blended probabilistic and deterministic evaluation techniques were used to establish inservice test strategies including both test methods and test frequency. Described in the paper are the methods and criteria for establishing MOV safety significance based on the STPEGS probabilistic safety assessment, deterministic considerations of MOV performance characteristics and performance margins, the expert panel evaluation process, and the development of inservice test strategies. Test strategies include a mix of dynamic and static testing as well as MOV exercising.

  2. Optimized periodic verification testing blended risk and performance-based MOV inservice test program an application of ASME code case OMN-1

    International Nuclear Information System (INIS)

    Sellers, C.; Fleming, K.; Bidwell, D.; Forbes, P.

    1996-01-01

    This paper presents an application of ASME Code Case OMN-1 to the GL 89-10 Program at the South Texas Project Electric Generating Station (STPEGS). Code Case OMN-1 provides guidance for a performance-based MOV inservice test program that can be used for periodic verification testing and allows consideration of risk insights. Blended probabilistic and deterministic evaluation techniques were used to establish inservice test strategies including both test methods and test frequency. Described in the paper are the methods and criteria for establishing MOV safety significance based on the STPEGS probabilistic safety assessment, deterministic considerations of MOV performance characteristics and performance margins, the expert panel evaluation process, and the development of inservice test strategies. Test strategies include a mix of dynamic and static testing as well as MOV exercising

  3. Reliability tests for reactor internals replacement technology

    International Nuclear Information System (INIS)

    Fujimaki, K.; Uchiyama, J.; Ohtsubo, T.

    2000-01-01

    Structural damage due to aging degradation of LWR reactor internals has been reported in several nuclear plants. NUPEC has started a project to test the reliability of the technology for replacing reactor internals, which was directed at preventive maintenance before damage and repair after damage for the aging degradation. The project has been funded by the Ministry of International Trade and Industry (MITI) of Japan since 1995, and it follows the policy of a report that the MITI has formally issued in April 1996 summarizing the countermeasures to be considered for aging nuclear plants and equipment. This paper gives an outline of the whole test plans and the test results for the BWR reactor internals replacement methods; core shroud, ICM housing, and CRD Housing and stub tube. The test results have shown that the methods were reliable and the structural integrity was appropriate based on the evaluation. (author)

  4. Burnup verification tests with the FORK measurement system-implementation for burnup credit

    International Nuclear Information System (INIS)

    Ewing, R.I.

    1994-01-01

    Verification measurements may be used to help ensure nuclear criticality safety when burnup credit is applied to spent fuel transport and storage systems. The FORK system measures the passive neutron and gamma-ray emission from spent fuel assemblies while in the storage pool. It was designed at Los Alamos National Laboratory for the International Atomic Energy Agency safeguards program and is well suited to verify burnup and cooling time records at commercial Pressurized Water Reactor (PWR) sites. This report deals with the application of the FORK system to burnup credit operations

  5. Verification of the test stand for microbolometer camera in accredited laboratory

    Science.gov (United States)

    Krupiński, Michal; Bareła, Jaroslaw; Chmielewski, Krzysztof; Kastek, Mariusz

    2017-10-01

    Microbolometer belongs to the group of thermal detectors and consist of temperature sensitive resistor which is exposed to measured radiation flux. Bolometer array employs a pixel structure prepared in silicon technology. The detecting area is defined by a size of thin membrane, usually made of amorphous silicon (a-Si) or vanadium oxide (VOx). FPAs are made of a multitude of detector elements (for example 384 × 288 ), where each individual detector has different sensitivity and offset due to detector-to-detector spread in the FPA fabrication process, and additionally can change with sensor operating temperature, biasing voltage variation or temperature of the observed scene. The difference in sensitivity and offset among detectors (which is called non-uniformity) additionally with its high sensitivity, produces fixed pattern noise (FPN) on produced image. Fixed pattern noise degrades parameters of infrared cameras like sensitivity or NETD. Additionally it degrades image quality, radiometric accuracy and temperature resolution. In order to objectively compare the two infrared cameras ones must measure and compare their parameters on a laboratory test stand. One of the basic parameters for the evaluation of a designed camera is NETD. In order to examine the NETD, parameters such as sensitivity and pixels noise must be measured. To do so, ones should register the output signal from the camera in response to the radiation of black bodies at two different temperatures. The article presets an application and measuring stand for determining the parameters of microbolometers camera. Prepared measurements were compared with the result of the measurements in the Institute of Optoelectronics, MUT on a METS test stand by CI SYSTEM. This test stand consists of IR collimator, IR standard source, rotating wheel with test patterns, a computer with a video grabber card and specialized software. The parameters of thermals cameras were measure according to norms and method described

  6. Reliability tests for reactor internals rejuvenation technology

    International Nuclear Information System (INIS)

    Fujimaki, Katsumi; Hitoki, Yoichi; Otsubo, Toru; Uchiyama, Junichi

    1998-01-01

    Structural damage due to aging degradation of LWR reactor internals has been reported in several nuclear plants. NUPEC has started a project to test the reliability of the technology for rejuvenating reactor internals which has been funded by the Ministry of International Trade and Industry (MITI) of Japan since 1995. The project follows the policy of a report that the MITI has formally issued in April 1996 summarizing the countermeasures to be considered for aging nuclear plants and equipment. This paper gives an outline of the test plans and results which are directed at preventive maintenance before damage and repair after damage for reactor internals aging degradation. The test results for the replacement methods of ICM housing and BWR core shroud have shown that the methods were reliable and the structural integrity was appropriate based on the evaluation. (author)

  7. In-Field Performance Testing of the Fork Detector for Quantitative Spent Fuel Verification

    Energy Technology Data Exchange (ETDEWEB)

    Gauld, Ian C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hu, Jianwei [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); De Baere, P. [European Commission (Luxembourg). DG Energy, Directorate Nuclear Safeguards; Vaccaro, S. [European Commission (Luxembourg). DG Energy, Directorate Nuclear Safeguards; Schwalbach, P. [European Commission (Luxembourg). DG Energy, Directorate Nuclear Safeguards; Liljenfeldt, Henrik [Swedish Nuclear Fuel and Waste Management Company (Sweden); Tobin, Stephen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-01-01

    Expanding spent fuel dry storage activities worldwide are increasing demands on safeguards authorities that perform inspections. The European Atomic Energy Community (EURATOM) and the International Atomic Energy Agency (IAEA) require measurements to verify declarations when spent fuel is transferred to difficult-to-access locations, such as dry storage casks and the repositories planned in Finland and Sweden. EURATOM makes routine use of the Fork detector to obtain gross gamma and total neutron measurements during spent fuel inspections. Data analysis is performed by modules in the integrated Review and Analysis Program (iRAP) software, developed jointly by EURATOM and the IAEA. Under the framework of the US Department of Energy–EURATOM cooperation agreement, a module for automated Fork detector data analysis has been developed by Oak Ridge National Laboratory (ORNL) using the ORIGEN code from the SCALE code system and implemented in iRAP. EURATOM and ORNL recently performed measurements on 30 spent fuel assemblies at the Swedish Central Interim Storage Facility for Spent Nuclear Fuel (Clab), operated by the Swedish Nuclear Fuel and Waste Management Company (SKB). The measured assemblies represent a broad range of fuel characteristics. Neutron count rates for 15 measured pressurized water reactor assemblies are predicted with an average relative standard deviation of 4.6%, and gamma signals are predicted on average within 2.6% of the measurement. The 15 measured boiling water reactor assemblies exhibit slightly larger deviations of 5.2% for the gamma signals and 5.7% for the neutron count rates, compared to measurements. These findings suggest that with improved analysis of the measurement data, existing instruments can provide increased verification of operator declarations of the spent fuel and thereby also provide greater ability to confirm integrity of an assembly. These results support the application of the Fork detector as a fully quantitative spent fuel

  8. Verification of the HDR-test V44 using the computer program RALOC-MOD1/83

    International Nuclear Information System (INIS)

    Jahn, H.; Pham, T. v.; Weber, G.; Pham, B.T.

    1985-01-01

    RALOC-MOD1/83 was extended by a drainage and sump level modul and several component models to serve as a containment systems code for various LWR types. One such application is to simulate the blowdown in a full pressure containment which is important for the short and long term hydrogen distribution. The post test calculation of the containment standard problem experiment HDR-V44 shows a good agreement, to the test data. The code may be used for short and long term predictions, but it was learned that double containments need the representation of the gap between the inner and outer shell into several zones to achieve a good long-term temperature prediction. The present work completes the development, verification and documentation of RALOC-MOD1. (orig.) [de

  9. Requirement Assurance: A Verification Process

    Science.gov (United States)

    Alexander, Michael G.

    2011-01-01

    Requirement Assurance is an act of requirement verification which assures the stakeholder or customer that a product requirement has produced its "as realized product" and has been verified with conclusive evidence. Product requirement verification answers the question, "did the product meet the stated specification, performance, or design documentation?". In order to ensure the system was built correctly, the practicing system engineer must verify each product requirement using verification methods of inspection, analysis, demonstration, or test. The products of these methods are the "verification artifacts" or "closure artifacts" which are the objective evidence needed to prove the product requirements meet the verification success criteria. Institutional direction is given to the System Engineer in NPR 7123.1A NASA Systems Engineering Processes and Requirements with regards to the requirement verification process. In response, the verification methodology offered in this report meets both the institutional process and requirement verification best practices.

  10. Satellite Power Systems (SPS) concept definition study. Volume 6: SPS technology requirements and verification

    Science.gov (United States)

    Hanley, G.

    1978-01-01

    Volume 6 of the SPS Concept Definition Study is presented and also incorporates results of NASA/MSFC in-house effort. This volume includes a supporting research and technology summary. Other volumes of the final report that provide additional detail are as follows: (1) Executive Summary; (2) SPS System Requirements; (3) SPS Concept Evolution; (4) SPS Point Design Definition; (5) Transportation and Operations Analysis; and Volume 7, SPS Program Plan and Economic Analysis.

  11. INNOVATIVE TECHNOLOGY VERIFICATION REPORT "FIELD MEASUREMENT TECHNOLOGIES FOR TOTAL PETROLEUM HYDROCARBONS IN SOIL" DEXSIL CORPORATION PETROFLAG SYSTEM

    Science.gov (United States)

    The PetroFLAGTm System developed by Dexsilo Corporation (Dexsil) was demonstrated under the U.S. Environmental Protection Agency Superfund Innovative Technology Evaluation Program in June 2000 at the Navy Base Ventura County site in Port Hueneme, California. The purpose o...

  12. Accumulation of operational history through emulation test to meet proven technology requirement for newly developed I and C technology

    International Nuclear Information System (INIS)

    Yeong Cheol, Shin; Sung Kon, Kang; Han Seong, Son

    2006-01-01

    As new advanced digital I and C technology with potential benefits of higher functionality and better cost effectiveness is available in the market, NPP (Nuclear Power Plant) operators are inclined to use the new technology for the construction of new plant and the upgrade of existing plants. However, this new technology poses risks to the NPP operators at the same time. These risks are mainly due to the poor reliability of newly developed technology. KHNP's past experiences with the new equipment shows many cases of reliability problems. And their consequences include unintended plant trips, lowered acceptance of the new digital technology by the plant I and C maintenance crew, and increased licensing burden in answering for questions from the nuclear regulatory body. Considering the fact that the risk of these failures in the nuclear plant operation is far greater than those in other industry, nuclear power plant operators want proven technology for I and C systems. This paper presents an approach for the emulation of operational history through which a newly developed technology becomes a proven technology. One of the essential elements of this approach is the feedback scheme of running the new equipment in emulated environment, gathering equipment failure, and correcting the design(and test bed). The emulation of environment includes normal and abnormal events of the new equipment such as reconfiguration of control system due to power failure, plant operation including full spectrum of credible scenarios in an NPP. Emulation of I and C equipment execution mode includes normal operation, initialization and termination, abnormal operation, hardware maintenance and maintenance of algorithm/software. Plant specific simulator is used to create complete profile of plant operational conditions that I and C equipment is to experience in the real plant. Virtual operating crew technology is developed to run the simulator scenarios without involvement of actual operators

  13. Seismic verification of underground explosions

    International Nuclear Information System (INIS)

    Glenn, L.A.

    1985-06-01

    The first nuclear test agreement, the test moratorium, was made in 1958 and lasted until the Soviet Union unilaterally resumed testing in the atmosphere in 1961. It was followed by the Limited Test Ban Treaty of 1963, which prohibited nuclear tests in the atmosphere, in outer space, and underwater. In 1974 the Threshold Test Ban Treaty (TTBT) was signed, limiting underground tests after March 1976 to a maximum yield of 250 kt. The TTBT was followed by a treaty limiting peaceful nuclear explosions and both the United States and the Soviet Union claim to be abiding by the 150-kt yield limit. A comprehensive test ban treaty (CTBT), prohibiting all testing of nuclear weapons, has also been discussed. However, a verifiable CTBT is a contradiction in terms. No monitoring technology can offer absolute assurance that very-low-yield illicit explosions have not occurred. The verification process, evasion opportunities, and cavity decoupling are discussed in this paper

  14. Integration of multidisciplinary technologies for real time target visualization and verification for radiotherapy

    Directory of Open Access Journals (Sweden)

    Chang WC

    2014-06-01

    Full Text Available Wen-Chung Chang,1,* Chin-Sheng Chen,2,* Hung-Chi Tai,3 Chia-Yuan Liu,4,5 Yu-Jen Chen3 1Department of Electrical Engineering, National Taipei University of Technology, Taipei, Taiwan; 2Graduate Institute of Automation Technology, National Taipei University of Technology, Taipei, Taiwan; 3Department of Radiation Oncology, Mackay Memorial Hospital, Taipei, Taiwan; 4Department of Internal Medicine, Mackay Memorial Hospital, Taipei, Taiwan; 5Department of Medicine, Mackay Medical College, New Taipei City, Taiwan  *These authors contributed equally to this work Abstract: The current practice of radiotherapy examines target coverage solely from digitally reconstructed beam's eye view (BEV in a way that is indirectly accessible and that is not in real time. We aimed to visualize treatment targets in real time from each BEV. The image data of phantom or patients from ultrasound (US and computed tomography (CT scans were captured to perform image registration. We integrated US, CT, US/CT image registration, robotic manipulation of US, a radiation treatment planning system, and a linear accelerator to constitute an innovative target visualization system. The performance of this algorithm segmented the target organ in CT images, transformed and reconstructed US images to match each orientation, and generated image registration in real time mode with acceptable accuracy. This image transformation allowed physicians to visualize the CT image-reconstructed target via a US probe outside the BEV that was non-coplanar to the beam's plane. It allowed the physicians to remotely control the US probe that was equipped on a robotic arm to dynamically trace and real time monitor the coverage of the target within the BEV during a simulated beam-on situation. This target visualization system may provide a direct remotely accessible and real time way to visualize, verify, and ensure tumor targeting during radiotherapy. Keywords: ultrasound, computerized tomography

  15. CTBT verification-related technologies for peaceful purposes: Implementation of CTBT in Iran

    International Nuclear Information System (INIS)

    Ghafory-Ashtiany, M.; Hosseinie, Mohammad-Taghi

    1999-01-01

    Based on its strong policy on disarmament and non proliferation, Islamic Republic of Iran considers CTBT as one of the measures towards the safe world and free from nuclear weapons. It is believed that full implementation of this treaty increases international security as well as national security of every state signatory. It is also considered that it has many scientific and technological benefits for sustainable development of the countries. This paper deals with international monitoring system in Iran, including primary and auxiliary seismic stations, infrasound and radionuclides monitoring systems

  16. Nuclear cooperation targets global challenges. States back main pillars of the IAEA's work to strengthen nuclear safety, verification and technology transfer

    International Nuclear Information System (INIS)

    2000-01-01

    States meeting at the 44th IAEA General Conference in Vienna have set a challenging agenda for international nuclear cooperation into the 21st century that targets issues of global safety, security, and sustainable development. They adopted resolutions endorsing the Agency's programmes for strengthening activities under its three main pillars of work - nuclear verification, safety, and technology - that are closely linked to major challenges before the world. The document presents the main actions taken during the conference

  17. Off reactor testings. Technological engineering applicative research

    International Nuclear Information System (INIS)

    Doca, Cezar

    2001-01-01

    By the end of year 2000 over 400 nuclear electro-power units were operating world wide, summing up a 350,000 MW total capacity, with a total production of 2,300 TWh, representing 16% of the world's electricity production. Other 36 units, totalizing 28,000 MW, were in construction, while a manifest orientation towards nuclear power development was observed in principal Asian countries like China, India, Japan and Korea. In the same world's trend one find also Romania, the Cernavoda NPP Unit 1 generating electrical energy into the national system beginning with 2 December 1996. Recently, the commercial contract was completed for finishing the Cernavoda NPP Unit 2 and launching it into operation by the end of year 2004. An important role in developing the activity of research and technological engineering, as technical support for manufacturing the CANDU type nuclear fuel and supplying with equipment the Cernavoda units, was played by the Division 7 TAR of the INR Pitesti. Qualification testings were conducted for: - off-reactor CANDU type nuclear fuel; - FARE tools, pressure regulators, explosion proof panels; channel shutting, as well as functional testing for spare pushing facility as a first step in the frame of the qualification tests for the charging/discharging machine (MID) 4 and 5 endings. Testing facilities are described, as well as high pressure hot/cool loops, measuring chains, all of them fulfilling the requirements of quality assurance. The nuclear fuel off-reactor tests were carried out to determine: strength; endurance; impact, pressure fall and wear resistance. For Cernavoda NPP equipment testings were carried out for: the explosion proof panels, pressure regulators, behaviour to vibration and wear of the steam generation tubings, effects of vibration upon different electronic component, channel shutting (for Cernavoda Unit 2), MID operating at 300 and 500 cycles. A number of R and D programs were conducted in the frame of division 7 TAR of INR

  18. Verification of best available technology for the 300 Area Treated Effluent Disposal Facility (310 Facility)

    International Nuclear Information System (INIS)

    Wagner, R.N.

    1994-01-01

    This compilation of Project L-045H reference materials documents that the 300 Area Treated Effluent Disposal Facility (TEDF, also designated the 310 Facility) was designed, built, and will be operated in accordance with the best available technology (BAT) identified in the Engineering Summary Report. The facility is intended for treatment of 300 Area process sewer wastewater. The following unit operations for 300 Area process sewer water treatment are specified as: influent receipt; iron co-precipitation and sludge handling for removal of heavy metals and initial suspended solids; ion exchanged for removal of mercury and other heavy metals; ultraviolet (UV)/peroxide treatment for destruction of organic compounds, cyanide, coliforms, sulfide, and nitrite; and effluent discharge to the Columbia River with pH monitoring/control capability

  19. Environmental Technology Verification Report for Private Pallet Security Systems, LLC. MultiTrack™ Layered Tracking Systems

    Science.gov (United States)

    This test simulated shipments of hazardous waste contained in polyethylene (poly) drums, metal drums, and corrugated boxes through routine land transportation routes and across international ports of entry in the El Paso/Ciudad Juarez trade area. RFID tags were attached to four ...

  20. Development of the SEAtrace{trademark} barrier verification and validation technology. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Dunn, S.D.; Lowry, W.; Walsh, R.; Rao, D.V. [Science and Engineering Associates, Santa Fe, NM (United States); Williams, C. [Sandia National Labs., Albuquerque, NM (United States). Underground Storage Technology Dept.

    1998-08-01

    In-situ barrier emplacement techniques and materials for the containment of high-risk contaminants in soils are currently being developed by the Department of Energy (DOE). Because of their relatively high cost, the barriers are intended to be used in cases where the risk is too great to remove the contaminants, the contaminants are too difficult to remove with current technologies, or the potential movement of the contaminants to the water table is so high that immediate action needs to be taken to reduce health risks. Assessing the integrity of the barrier once it is emplaced, and during its anticipated life, is a very difficult but necessary requirement. Science and Engineering Associates, Inc., (SEA) and Sandia National Laboratories (SNL) have developed a quantitative subsurface barrier assessment system using gaseous tracers in support of the Subsurface Contaminants Focus Area barrier technology program. Called SEAtrace{trademark}, this system integrates an autonomous, multi-point soil vapor sampling and analysis system with a global optimization modeling methodology to locate and size barrier breaches in real time. The methodology for the global optimization code was completed and a prototype code written using simplifying assumptions. Preliminary modeling work to validate the code assumptions were performed using the T2VOC numerical code. A multi-point field sampling system was built to take soil gas samples and analyze for tracer gas concentration. The tracer concentration histories were used in the global optimization code to locate and size barrier breaches. SEAtrace{trademark} was consistently able to detect and locate leaks, even under very adverse conditions. The system was able to locate the leak to within 0.75 m of the actual value, and was able to determine the size of the leak to within 0.15 m.

  1. Monitoring and verification R&D

    Energy Technology Data Exchange (ETDEWEB)

    Pilat, Joseph F [Los Alamos National Laboratory; Budlong - Sylvester, Kory W [Los Alamos National Laboratory; Fearey, Bryan L [Los Alamos National Laboratory

    2011-01-01

    The 2010 Nuclear Posture Review (NPR) report outlined the Administration's approach to promoting the agenda put forward by President Obama in Prague on April 5, 2009. The NPR calls for a national monitoring and verification R&D program to meet future challenges arising from the Administration's nonproliferation, arms control and disarmament agenda. Verification of a follow-on to New START could have to address warheads and possibly components along with delivery capabilities. Deeper cuts and disarmament would need to address all of these elements along with nuclear weapon testing, nuclear material and weapon production facilities, virtual capabilities from old weapon and existing energy programs and undeclared capabilities. We only know how to address some elements of these challenges today, and the requirements may be more rigorous in the context of deeper cuts as well as disarmament. Moreover, there is a critical need for multiple options to sensitive problems and to address other challenges. There will be other verification challenges in a world of deeper cuts and disarmament, some of which we are already facing. At some point, if the reductions process is progressing, uncertainties about past nuclear materials and weapons production will have to be addressed. IAEA safeguards will need to continue to evolve to meet current and future challenges, and to take advantage of new technologies and approaches. Transparency/verification of nuclear and dual-use exports will also have to be addressed, and there will be a need to make nonproliferation measures more watertight and transparent. In this context, and recognizing we will face all of these challenges even if disarmament is not achieved, this paper will explore possible agreements and arrangements; verification challenges; gaps in monitoring and verification technologies and approaches; and the R&D required to address these gaps and other monitoring and verification challenges.

  2. Monitoring and verification R and D

    International Nuclear Information System (INIS)

    Pilat, Joseph F.; Budlong-Sylvester, Kory W.; Fearey, Bryan L.

    2011-01-01

    The 2010 Nuclear Posture Review (NPR) report outlined the Administration's approach to promoting the agenda put forward by President Obama in Prague on April 5, 2009. The NPR calls for a national monitoring and verification R and D program to meet future challenges arising from the Administration's nonproliferation, arms control and disarmament agenda. Verification of a follow-on to New START could have to address warheads and possibly components along with delivery capabilities. Deeper cuts and disarmament would need to address all of these elements along with nuclear weapon testing, nuclear material and weapon production facilities, virtual capabilities from old weapon and existing energy programs and undeclared capabilities. We only know how to address some elements of these challenges today, and the requirements may be more rigorous in the context of deeper cuts as well as disarmament. Moreover, there is a critical need for multiple options to sensitive problems and to address other challenges. There will be other verification challenges in a world of deeper cuts and disarmament, some of which we are already facing. At some point, if the reductions process is progressing, uncertainties about past nuclear materials and weapons production will have to be addressed. IAEA safeguards will need to continue to evolve to meet current and future challenges, and to take advantage of new technologies and approaches. Transparency/verification of nuclear and dual-use exports will also have to be addressed, and there will be a need to make nonproliferation measures more watertight and transparent. In this context, and recognizing we will face all of these challenges even if disarmament is not achieved, this paper will explore possible agreements and arrangements; verification challenges; gaps in monitoring and verification technologies and approaches; and the R and D required to address these gaps and other monitoring and verification challenges.

  3. Environmental assessment report: Nuclear Test Technology Complex

    International Nuclear Information System (INIS)

    Tonnessen, K.; Tewes, H.A.

    1982-08-01

    The US Department of Energy (USDOE) is planning to construct and operate a structure, designated the Nuclear Test Technology Complex (NTTC), on a site located west of and adjacent to the Lawrence Livermore National Laboratory. The NTTC is designed to house 350 nuclear test program personnel, and will accommodate the needs of the entire staff of the continuing Nuclear Test Program (NTP). The project has three phases: land acquisition, facility construction and facility operation. The purpose of this environmental assessment report is to describe the activities associated with the three phases of the NTTC project and to evaluate potential environmental disruptions. The project site is located in a rural area of southeastern Alameda County, California, where the primary land use is agriculture; however, the County has zoned the area for industrial development. The environmental impacts of the project include surface disturbance, high noise levels, possible increases in site erosion, and decreased air quality. These impacts will occur primarily during the construction phase of the NTTC project and can be mitigated in part by measures proposed in this report

  4. Verification of new technologies introduced into the privately-owned port of Higashidori Nuclear Power Station

    International Nuclear Information System (INIS)

    Murano, Sei-ichiro; Ozaki, Tsutomu; Date, Masanao

    2005-01-01

    The privately-owned port of Higashidori Nuclear Power Station introduced the rubble-slopping breakwater as the seawall and the concrete-caisson breakwater (new caisson breakwater) as the outlet seawall. The distribution of wave pressure on the new caisson breakwater was measured by the wave pressure meteor set on it and compared with the results of the hydraulic model tests. The precast concrete armour unit used Acropod. The conditions of new caisson breakwater, measurement of wave pressure, and the optimum conditions of seawall are stated. The new caisson breakwater showed the high dispersive effect of the impact wave force on the surf zone. The construction cost was decreased by reduction of sectional area and the wave dissipating concrete block. There are no problems about the stability of breakwater confirmed by the hydraulic model test. (S.Y.)

  5. Arms Control and nonproliferation technologies: Technology options and associated measures for monitoring a Comprehensive Test Ban, Second quarter

    Energy Technology Data Exchange (ETDEWEB)

    Casey, Leslie A.

    1994-01-01

    This newsletter contains reprinted papers discussing technology options and associated measures for monitoring a Comprehensive Test Ban Treaty (CTBT). These papers were presented to the Conference on Disarmament (CD) in May and June 1994. An interagency Verification Monitoring Task Force developed the papers. The task force included participants from the Arms Control and Disarmament Agency, the Department of Defense, the Department of Energy, the Intelligence Community, the Department of Interior, and the Department of State. The purpose of this edition of Arms Control and Nonproliferation Technologies is to share these papers with the broad base of stakeholders in a CTBT and to facilitate future technology discussions. The papers in the first group discuss possible technology options for monitoring a CTBT in all environments (underground, underwater, atmosphere, and space). These technologies, along with on-site inspections, would facilitate CTBT monitoring by treaty participants. The papers in the second group present possible associated measures, e.g., information exchanges and transparency measures, that would build confidence among states participating in a CTBT.

  6. Environmental Technology Verification Report for Avante International Technology, Inc., PanaSec Mobile Personnel and Asset Visibility System

    Science.gov (United States)

    Ths test simulated through routine land transportation routes and across international ports of entry in the El Paso/Ciudad Juarez trade area. RFID tags were attached to four of each container type for a total of 12 containers which were loaded onto a standard 53-foot semi-truck...

  7. Research on Digital Output Verification Technology of Electronic DC Current Transformer

    Science.gov (United States)

    Chen, Yuanjie; Wang, Bin; Hu, Haoliang; Xiong, Qianzhu; Yang, Chunyan

    2017-05-01

    Aiming at the error of calibration system when conducting field calibration by electronic DC current transformer’s digital calibration system, an electronic DC current transformer’s digital calibration system based on protocol conversion is proposed and researched. Data frames outputted from merging unit are collected and converted by the system, the digital synchronization is realized by using the synchronous clock device to trigger the second pulse, and it is verified by the virtual instrument design software. The field calibration is conducted to some converter station digital dc current transformer under the rated current of 500A by using the calibration system. By calibrating and analyzing errors, the error is less than 0.075% when tested current is more than 40% of the rated current. According the standard in literature[1], performance of the calibration system is perfect, measured results perfectly meet the requirements of design, and the calibration system has great practical application value.

  8. FY 1983 report on the results of the verification test on the methanol conversion for oil-fired power plant. Part 1. Verification test on the environmental safety; 1983 nendo sekiyu karyoku hatsudensho metanoru tenkan tou jissho shiken seika hokokusho. Kankyo anzensei jissho shiken (Sono 1)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1984-03-01

    As to the verification test on the environmental safety in the use of methanol as power generation use fuel, the following were summed up: review of the verification test and the interim evaluation, state of implementation of the FY 1983 verification test, study/evaluation of the results of the FY 1983 test, survey of research trends, plan of the FY 1984 verification test, record of the committee, etc. Concerning the interim evaluation, high evaluation was obtained as described below: Testing facilities were constructed as planned at first to make the implementation of various tests possible; Tests were smoothly conducted, and among the acute test using monkey, test on mock flue gas using monkey/rat, test on mutagenicity and test on the effect on aquatic animals, tests using oryzias latipes and abalone on the fatal concentration, avoidance behavior and chronic effect were finished by the end of FY 1983 almost as planned; The long-term inhalation test using monkey and rat/mouse has been smoothly in progress. In the survey of research trends, the paper introduced the outlined literature on the methanol metabolism of monkey, changes in the methanol concentration in blood/urine in the case of drinking methanol by mistake. (NEDO)

  9. Science and Technology Test Mining: Disruptive Technology Roadmaps

    Science.gov (United States)

    2003-07-23

    2330, 2002. This paper discusses how peer-to-peer computing is emerging as a disruptive technology for global collaborative solutions. It explains how...8217brand image’ of nation-states on a global plane. The article critiques the notion that new media, especially the internet, are disruptive technologies ...advantage over potential adversaries. The widespread access to a wide variety of modern top of the fine technologies made possible by the globalization of

  10. Testing of the dual slab verification detector for attended measurements of the BN-350 dry storage casks

    Energy Technology Data Exchange (ETDEWEB)

    Santi, Peter A [Los Alamos National Laboratory; Browne, Michael C [Los Alamos National Laboratory; Williams, Richard B [Los Alamos National Laboratory; Parker, Robert F [Los Alamos National Laboratory

    2009-01-01

    The Dual Slab Verification Detector (DSVD) has been developed and built by Los Alamos National Laboratory in cooperation with the International Atomic Energy Agency (IAEA) as part of the dry storage safeguards system for the spent fuel from the BN-350 fast reactor. The detector consists of two rows of {sup 3}He tubes embedded in a slab of polyethylene which has been designed to be placed on the outer surface of the dry storage cask. The DSVD will be used to perform measurements of the neutron flux emanating from inside the dry storage cask at several locations around each cask to establish a neutron 'fingerprint' that is sensitive to the contents of the cask. The sensitivity of the fingerprinting technique to the removal of specific amount of nuclear material from the cask is determined by the characteristics of the detector that is used to perform the measurements, the characteristics of the spent fuel being measured, and systematic uncertainties that are associated with the dry storage scenario. MCNPX calculations of the BN-350 dry storage asks and layout have shown that the neutron fingerprint verification technique using measurements from the DSVD would be sensitive to both the amount and location of material that is present within an individual cask. To confirm the performance of the neutron fingerprint technique in verifying the presence of BN-350 spent fuel in dry storage, an initial series of measurements have been performed to test the performance and characteristics of the DSVD. Results of these measurements will be presented and compared with MCNPX results.

  11. Testing of the dual slab verification detector for attended measurements of the BN-350 dry storage casks

    International Nuclear Information System (INIS)

    Santi, Peter A.; Browne, Michael C.; Williams, Richard B.; Parker, Robert F.

    2009-01-01

    The Dual Slab Verification Detector (DSVD) has been developed and built by Los Alamos National Laboratory in cooperation with the International Atomic Energy Agency (IAEA) as part of the dry storage safeguards system for the spent fuel from the BN-350 fast reactor. The detector consists of two rows of 3 He tubes embedded in a slab of polyethylene which has been designed to be placed on the outer surface of the dry storage cask. The DSVD will be used to perform measurements of the neutron flux emanating from inside the dry storage cask at several locations around each cask to establish a neutron 'fingerprint' that is sensitive to the contents of the cask. The sensitivity of the fingerprinting technique to the removal of specific amount of nuclear material from the cask is determined by the characteristics of the detector that is used to perform the measurements, the characteristics of the spent fuel being measured, and systematic uncertainties that are associated with the dry storage scenario. MCNPX calculations of the BN-350 dry storage asks and layout have shown that the neutron fingerprint verification technique using measurements from the DSVD would be sensitive to both the amount and location of material that is present within an individual cask. To confirm the performance of the neutron fingerprint technique in verifying the presence of BN-350 spent fuel in dry storage, an initial series of measurements have been performed to test the performance and characteristics of the DSVD. Results of these measurements will be presented and compared with MCNPX results.

  12. Future Combat System Spinout 1 Technical Field Test - Establishing and Implementing Models and Simulations System of Systems Verification, Validation and Accreditation Practices, Methodologies and Procedures

    Science.gov (United States)

    2009-11-24

    IV&V Independent Verification and Validation JTRS Joint Tactical Radio System JVMF Joint Variable Message Format LDAP Lightweight Directory Access...Protocol LDIF LDAP Data Interchange Format LSI Lead Systems Integrator LUT Limited User Test MCS Mounted Combat System / Mobility Computer System

  13. Nist Microwave Blackbody: The Design, Testing, and Verification of a Conical Brightness Temperature Source

    Science.gov (United States)

    Houtz, Derek Anderson

    maximized emissivity are fundamental to a well characterized blackbody. The chosen geometry is a microwave absorber coated copper cone. Electromagnetic and thermal simulations are introduced to optimize the design. Experimental verifications of the simulated quantities confirm the predicted performance of the blackbody.

  14. Comprehensive Test Ban Treaty (CTBT) Verification research in support of non-proliferation

    International Nuclear Information System (INIS)

    Linger, D.

    1997-01-01

    The Comprehensive Test Ban Treaty (CTBT) prohibits nuclear weapons testing at any yield. The detection and positive identification of any evasive test presents a challenge to the technical community, however. Low yield testing can be masked by normal background seismic noise or permissible chemical explosions for mining or other purposes. Cavity decoupling can reduce the seismic signal from the nuclear explosion by a factor of 50 or more. The combination of decoupling and high explosive masking represents a particular technical challenge for positive identification. To address this problem, a technical program in cooperation with the Kazakhstan National Nuclear Center has been initiated to conduct a series of tests in the Balapan area of the Semipalatinsk Test Site to provide fundamental data on the depth of burial effects on seismic signals emanating from an explosion. If the depth of burial can be positively determined from the characteristics of the seismic waveform, near-surface mining blasts can be distinguished from deep underground evasive nuclear explosions, thus eliminating the capability to easily mask the nuclear event. This paper will briefly describe the basic concepts of some evasive nuclear testing options and discuss the cooperative test program that is being carried out to improve the capability to positively identify such tests. The paper will also discuss possible additional cooperative tests that might be done in 1998 to further improve the identification capability

  15. Lay out, test verification and in orbit performance of HELIOS a temperature control system

    Science.gov (United States)

    Brungs, W.

    1975-01-01

    HELIOS temperature control system is described. The main design features and the impact of interactions between experiment, spacecraft system, and temperature control system requirements on the design are discussed. The major limitations of the thermal design regarding a closer sun approach are given and related to test experience and performance data obtained in orbit. Finally the validity of the test results achieved with prototype and flight spacecraft is evaluated by comparison between test data, orbit temperature predictions and flight data.

  16. Science and Technology Test Mining: Disruptive Technology Roadmaps

    National Research Council Canada - National Science Library

    Kostoff, Ronald

    2003-01-01

    Disruptive technologies create growth in the industries they penetrate or create entirely new industries through the introduction of products and services that are dramatically cheaper, better, and more convenient...

  17. Applications of aerospace technology in industry: A technology transfer profile, nondestructive testing

    Science.gov (United States)

    1972-01-01

    The development of nondestructive testing procedures by NASA and the transfer of nondestructive testing to technology to civilian industry are discussed. The subjects presented are: (1) an overview of the nondestructive testing field, (2) NASA contributions to the field of nondestructive testing, (3) dissemination of NASA contributions, and (4) a transfer profile. Attachments are included which provide a brief description of common nondestructive testing methods and summarize the technology transfer reports involving NASA generated nondestructive testing technology.

  18. Test and verification of a reactor protection system application-specific integrated circuit

    International Nuclear Information System (INIS)

    Battle, R.E.; Turner, G.W.; Vandermolen, R.I.; Vitalbo, C.

    1997-01-01

    Application-specific integrated circuits (ASICs) were utilized in the design of nuclear plant safety systems because they have certain advantages over software-based systems and analog-based systems. An advantage they have over software-based systems is that an ASIC design can be simple enough to not include branch statements and also can be thoroughly tested. A circuit card on which an ASIC is mounted can be configured to replace various versions of older analog equipment with fewer design types required. The approach to design and testing of ASICs for safety system applications is discussed in this paper. Included are discussions of the ASIC architecture, how it is structured to assist testing, and of the functional and enhanced circuit testing

  19. A Strategy for Automatic Quality Signing and Verification Processes for Hardware and Software Testing

    Directory of Open Access Journals (Sweden)

    Mohammed I. Younis

    2010-01-01

    Circuits in a production line. Comparatively, our result demonstrates that the proposed strategy outperforms the traditional block partitioning strategy with the mutant score of 100% to 90%, respectively, with the same number of test cases.

  20. Finite Element Verification of Non-Homogeneous Strain and Stress Fields during Composite Material Testing

    DEFF Research Database (Denmark)

    Mikkelsen, Lars Pilgaard

    2015-01-01

    strength and fatigue performance is essential. Nevertheless, testing composites includes some challenges regarding stiffness determination using conventional strain gauges and achieving correct material failure unaffected by the gripping region during fatigue testing. Challenges, which in the present study......Uni-directional glass fiber reinforced polymers play a central role in the task increasing the length of wind turbines blades and thereby lowering the cost of energy from wind turbine installations. During this, optimizing the mechanical performance regarding material stiffness, compression...

  1. Metrology test object for dimensional verification in additive manufacturing of metals for biomedical applications.

    Science.gov (United States)

    Teeter, Matthew G; Kopacz, Alexander J; Nikolov, Hristo N; Holdsworth, David W

    2015-01-01

    Additive manufacturing continues to increase in popularity and is being used in applications such as biomaterial ingrowth that requires sub-millimeter dimensional accuracy. The purpose of this study was to design a metrology test object for determining the capabilities of additive manufacturing systems to produce common objects, with a focus on those relevant to medical applications. The test object was designed with a variety of features of varying dimensions, including holes, cylinders, rectangles, gaps, and lattices. The object was built using selective laser melting, and the produced dimensions were compared to the target dimensions. Location of the test objects on the build plate did not affect dimensions. Features with dimensions less than 0.300 mm did not build or were overbuilt to a minimum of 0.300 mm. The mean difference between target and measured dimensions was less than 0.100 mm in all cases. The test object is applicable to multiple systems and materials, tests the effect of location on the build, uses a minimum of material, and can be measured with a variety of efficient metrology tools (including measuring microscopes and micro-CT). Investigators can use this test object to determine the limits of systems and adjust build parameters to achieve maximum accuracy. © IMechE 2014.

  2. CALIBRATION AND TESTING OF SONIC STIMULATION TECHNOLOGIES

    Energy Technology Data Exchange (ETDEWEB)

    Roger Turpening; Wayne Pennington; Christopher Schmidt; Sean Trisch

    2005-03-01

    In conjunction with Baker Atlas Inc. Michigan Technological University devised a system capable of recording the earth motion and pressure due to downhole and surface seismic sources. The essential elements of the system are (1) a borehole test site that will remain constant and is available all the time and for any length of time, (2) a downhole sonde that will itself remain constant and, because of its downhole digitization feature, does not require the wireline or surface recording components to remain constant, and (3) a set of procedures that ensures that the amplitude and frequency parameters of a wide range of sources can be compared with confidence. This system was used to record four seismic sources, three downhole sources and one surface source. A single activation of each of the downhole sources was not seen on time traces above the ambient noise, however, one sweep of the surface source, a small vertical vibrator, was easily seen in a time trace. One of the downhole sources was seen by means of a spike in its spectrum and a second downhole source was clearly seen after correlation and stacking. The surface vibrator produced a peak to peak particle motion signal of approximately 4.5 x 10{sup -5} cm/sec and a peak to peak pressure of approx. 2.5 x 10{sup -7} microPascals at a depth of 1,485 ft. Theoretical advances were made with our partner, Dr. Igor Beresnev at Iowa State University. A theory has been developed to account for the behavior of oil ganglia trapped in pore throats, and their ultimate release through the additional incremental pressure associated with sonic stimulation.

  3. Calibration and Testing of Sonic Stimulation Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Roger M. Turpening; Wayne D.Pennington

    2005-03-31

    In conjunction with Baker Atlas Inc. Michigan Technological University devised a system capable of recording the earth motion and pressure due to downhole and surface seismic sources. The essential elements of the system are 1) a borehole test site that will remain constant and is available all the time and for any length of time, 2) a downhole sonde that will itself remain constant and, because of its downhole digitization feature, does not require the wireline or surface recording components to remain constant, and 3) a set of procedures that ensures that the amplitude and frequency parameters of a wide range of sources can be compared with confidence. This system was used to record four seismic sources, three downhole sources and one surface source. A single activation of each of the downhole sources was not seen on time traces above the ambient noise, however, one sweep of the surface source, a small vertical vibrator, was easily seen in a time trace. One of the downhole sources was seen by means of a spike in its spectrum and a second downhole source was clearly seen after correlation and stacking. The surface vibrator produced a peak to peak particle motion signal of approximately 4.5 X 10-5 cm/sec and a peak to peak pressure of approx. 2.5 X 10-7 microPascals at a depth of 1,485 ft. Theoretical advances were made with our partner, Dr. I. Beresnev at Iowa State University. A theory has been developed to account for the behavior of oil ganglia trapped in pore throats, and their ultimate release through the additional incremental pressure associated with sonic stimulation.

  4. Formal Verification of Circuits and Systems

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    Today formal verification is finding increasing acceptance in some areas, especially model abstraction and functional verification. Other major chal- lenges, like timing verification, remain before this technology can be posed as a complete alternative to simulation. This special issue is devoted to presenting some of the ...

  5. Proceedings of the Joint IAEA/CSNI Specialists' Meeting on Fracture Mechanics Verification by Large-Scale Testing

    International Nuclear Information System (INIS)

    1993-10-01

    This report provides the proceedings of a Specialists' Meeting on Fracture Mechanics Verification by Large-Scale Testing that was held in Oak Ridge, Tennessee, on October 23-25, 1992. The meeting was jointly sponsored by the International Atomic Energy Agency (IAEA) and the Nuclear Energy Agency (NEA) of the Organization for Economic Cooperation and Development. In particular, the International Working Group (IWG) on Life Management of Nuclear Power Plants (LMNPP) was the IAEA sponsor, and the Principal Working Group 3 (PWG-3) (Primary System Component Integrity) of the Committee for the Safety of Nuclear Installations (CSNI) was the NEA's sponsor. This meeting was preceded by two prior international activities that were designed to examine the state-of-the-art in fracture analysis capabilities and emphasized applications to the safety evaluation of nuclear power facilities. The first of those two activities was an IAEA Specialists' Meeting on Fracture Mechanics Verification by Large-Scale Testing that was held at the Staatliche Materialprufungsanstalt (MPA) in Stuttgart, Germany, on May 25-27, 1988; the proceedings of that meeting were published 1991.1 The second activity was the CSNI/PWG-3's Fracture Assessment Group's Project FALSIRE (Fracture Analyses of Large-Scale International Reference Experiments). The proceedings of the FALSIRE workshop that was held in Boston, Massachusetts, U.S.A., on May 8-10, 1990, was recently published by the Oak Ridge National Laboratory (ORNL). Those previous activities identified capabilities and shortcomings of various fracture analysis methods based on analyses of six available large-scale experiments. Different modes of fracture behavior, which ranged from brittle to ductile, were considered. In addition, geometry, size, constraint and multiaxial effects were considered. While generally good predictive capabilities were demonstrated for brittle fracture, issues were identified relative to predicting fracture behavior at higher

  6. Oxygen/hydrogen technology test bed status update

    Science.gov (United States)

    Richards, J. S.

    1988-01-01

    An overview is provided of the Hydrogen/Oxygen Technology Test Bed program. The status of the program, the program direction, plans for testing, and plans for technology implementation within the program are delineated. Test Bed goals and objectives are defined and the current status of the Test Bed engine is provided. A test facility status and a summary of the test facility capabilities are given.

  7. Nuclear Data Verification and Standardization

    Energy Technology Data Exchange (ETDEWEB)

    Karam, Lisa R.; Arif, Muhammad; Thompson, Alan K.

    2011-10-01

    The objective of this interagency program is to provide accurate neutron interaction verification and standardization data for the U.S. Department of Energy Division of Nuclear Physics programs which include astrophysics, radioactive beam studies, and heavy-ion reactions. The measurements made in this program are also useful to other programs that indirectly use the unique properties of the neutron for diagnostic and analytical purposes. These include homeland security, personnel health and safety, nuclear waste disposal, treaty verification, national defense, and nuclear based energy production. The work includes the verification of reference standard cross sections and related neutron data employing the unique facilities and capabilities at NIST and other laboratories as required; leadership and participation in international intercomparisons and collaborations; and the preservation of standard reference deposits. An essential element of the program is critical evaluation of neutron interaction data standards including international coordinations. Data testing of critical data for important applications is included. The program is jointly supported by the Department of Energy and the National Institute of Standards and Technology.

  8. Report on results for fiscal 1996 on development of superconducting electric power application technology. Pt. 2. R and D of superconducting wire, R and D of superconducting generator, studies on total system, R and D of refrigeration system, and verification test; 1996 nendo chodendo denryoku oyo gijutsu kaihatsu seika hokokusho. 2. Chodendo senzai no kenkyu kaihatsu, chodendo hatsudenki no kenkyu kaihatsu, total system no kenkyu, reito system no kenkyu kaihatsu, jissho shiken

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-01

    In fiscal 1996, the initial cooling test and rotary excitation test were conducted for the 70,000kW slow-response type model machine, with the basic characteristics of the rotor verified such as the cooling characteristics, shaft vibration characteristics, mechanical strength, and superconductivity stability, and with the results of the studies explained. The rotor of the 70,000kW slow-response type model was installed in the test site, and the field test was carried out in 1997. For this purpose, research test was performed by the element technology of the model machine and the partial model. The technological development items, trial manufacture and test items were field winding, multi cylindrical rotor and damper. Upon the test results using the element and partial model, the design and manufacturing were implemented of the superconducting generator of a slow-response type excitation method with the output of 70,000kW class. Performed were the basic characteristic test, long-term operation test and severity test on the assumption of abnormality, verifying the characteristics and reliability of the generator as well as obtaining data concerning an excessive electromagnetic force and heat generation. From the test data and the analysis/evaluation results obtained on the model machine, the 200,000kW class pilot machine was reviewed in the conceptual design. (NEDO)

  9. Environmental assessment of general-purpose heat source safety verification testing

    International Nuclear Information System (INIS)

    1995-02-01

    This Environmental Assessment (EA) was prepared to identify and evaluate potential environmental, safety, and health impacts associated with the Proposed Action to test General-Purpose Heat Source (GPHS) Radioisotope Thermoelectric Generator (RTG) assemblies at the Sandia National Laboratories (SNL) 10,000-Foot Sled Track Facility, Albuquerque, New Mexico. RTGs are used to provide a reliable source of electrical power on board some spacecraft when solar power is inadequate during long duration space missions. These units are designed to convert heat from the natural decay of radioisotope fuel into electrical power. Impact test data are required to support DOE's mission to provide radioisotope power systems to NASA and other user agencies. The proposed tests will expand the available safety database regarding RTG performance under postulated accident conditions. Direct observations and measurements of GPHS/RTG performance upon impact with hard, unyielding surfaces are required to verify model predictions and to ensure the continual evolution of the RTG designs that perform safely under varied accident environments. The Proposed Action is to conduct impact testing of RTG sections containing GPHS modules with simulated fuel. End-On and Side-On impact test series are planned

  10. Environmental assessment of general-purpose heat source safety verification testing

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-02-01

    This Environmental Assessment (EA) was prepared to identify and evaluate potential environmental, safety, and health impacts associated with the Proposed Action to test General-Purpose Heat Source (GPHS) Radioisotope Thermoelectric Generator (RTG) assemblies at the Sandia National Laboratories (SNL) 10,000-Foot Sled Track Facility, Albuquerque, New Mexico. RTGs are used to provide a reliable source of electrical power on board some spacecraft when solar power is inadequate during long duration space missions. These units are designed to convert heat from the natural decay of radioisotope fuel into electrical power. Impact test data are required to support DOE`s mission to provide radioisotope power systems to NASA and other user agencies. The proposed tests will expand the available safety database regarding RTG performance under postulated accident conditions. Direct observations and measurements of GPHS/RTG performance upon impact with hard, unyielding surfaces are required to verify model predictions and to ensure the continual evolution of the RTG designs that perform safely under varied accident environments. The Proposed Action is to conduct impact testing of RTG sections containing GPHS modules with simulated fuel. End-On and Side-On impact test series are planned.

  11. Verification of Overall Safety Factors In Deterministic Design Of Model Tested Breakwaters

    DEFF Research Database (Denmark)

    Burcharth, H. F.

    2001-01-01

    The paper deals with concepts of safety implementation in design. An overall safety factor concept is evaluated on the basis of a reliability analysis of a model tested rubble mound breakwater with monolithic super structure. Also discussed are design load identification and failure mode limit...

  12. The test verification of 3D geodetic points and their changes

    Directory of Open Access Journals (Sweden)

    Vincent Jakub

    2007-06-01

    Full Text Available Approaches of congruency checks of 3D point field realisations applying repeated measurements. Investigation of 3D point displacement in various space direction using test procedures. Determination possibilities of 3D point movements and their significance by the confidence ellipsoids and their applications in practice.

  13. User input verification and test driven development in the NJOY21 nuclear data processing code

    Energy Technology Data Exchange (ETDEWEB)

    Trainer, Amelia Jo [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Conlin, Jeremy Lloyd [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); McCartney, Austin Paul [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-08-21

    Before physically-meaningful data can be used in nuclear simulation codes, the data must be interpreted and manipulated by a nuclear data processing code so as to extract the relevant quantities (e.g. cross sections and angular distributions). Perhaps the most popular and widely-trusted of these processing codes is NJOY, which has been developed and improved over the course of 10 major releases since its creation at Los Alamos National Laboratory in the mid-1970’s. The current phase of NJOY development is the creation of NJOY21, which will be a vast improvement from its predecessor, NJOY2016. Designed to be fast, intuitive, accessible, and capable of handling both established and modern formats of nuclear data, NJOY21 will address many issues that many NJOY users face, while remaining functional for those who prefer the existing format. Although early in its development, NJOY21 is quickly providing input validation to check user input. By providing rapid and helpful responses to users while writing input files, NJOY21 will prove to be more intuitive and easy to use than any of its predecessors. Furthermore, during its development, NJOY21 is subject to regular testing, such that its test coverage must strictly increase with the addition of any production code. This thorough testing will allow developers and NJOY users to establish confidence in NJOY21 as it gains functionality. This document serves as a discussion regarding the current state input checking and testing practices of NJOY21.

  14. Aerodynamics and performance verifications of test methods for laboratory fume cupboards.

    Science.gov (United States)

    Tseng, Li-Ching; Huang, Rong Fung; Chen, Chih-Chieh; Chang, Cheng-Ping

    2007-03-01

    The laser-light-sheet-assisted smoke flow visualization technique is performed on a full-size, transparent, commercial grade chemical fume cupboard to diagnose the flow characteristics and to verify the validity of several current containment test methods. The visualized flow patterns identify the recirculation areas that would inevitably exist in the conventional fume cupboards because of the fundamental configurations and structures. The large-scale vortex structures exist around the side walls, the doorsill of the cupboard and in the vicinity of the near-wake region of the manikin. The identified recirculation areas are taken as the 'dangerous' regions where the risk of turbulent dispersion of contaminants may be high. Several existing tracer gas containment test methods (BS 7258:1994, prEN 14175-3:2003 and ANSI/ASHRAE 110:1995) are conducted to verify the effectiveness of these methods in detecting the contaminant leakage. By comparing the results of the flow visualization and the tracer gas tests, it is found that the local recirculation regions are more prone to contaminant leakage because of the complex interaction between the shear layers and the smoke movement through the mechanism of turbulent dispersion. From the point of view of aerodynamics, the present study verifies that the methodology of the prEN 14175-3:2003 protocol can produce more reliable and consistent results because it is based on the region-by-region measurement and encompasses the most area of the entire recirculation zone of the cupboard. A modified test method combined with the region-by-region approach at the presence of the manikin shows substantially different results of the containment. A better performance test method which can describe an operator's exposure and the correlation between flow characteristics and the contaminant leakage properties is therefore suggested.

  15. Particularities of Verification Processes for Distributed Informatics Applications

    Directory of Open Access Journals (Sweden)

    Ion IVAN

    2013-01-01

    Full Text Available This paper presents distributed informatics applications and characteristics of their development cycle. It defines the concept of verification and there are identified the differences from software testing. Particularities of the software testing and software verification processes are described. The verification steps and necessary conditions are presented and there are established influence factors of quality verification. Software optimality verification is analyzed and some metrics are defined for the verification process.

  16. Verification test problems for the calculation of probability of loss of assured safety in temperature-dependent systems with multiple weak and strong links.

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Jay Dean (ProStat, Mesa, AZ); Oberkampf, William Louis; Helton, Jon Craig (Arizona State University, Tempe, AZ)

    2006-06-01

    Four verification test problems are presented for checking the conceptual development and computational implementation of calculations to determine the probability of loss of assured safety (PLOAS) in temperature-dependent systems with multiple weak links (WLs) and strong links (SLs). The problems are designed to test results obtained with the following definitions of loss of assured safety: (1) Failure of all SLs before failure of any WL, (2) Failure of any SL before failure of any WL, (3) Failure of all SLs before failure of all WLs, and (4) Failure of any SL before failure of all WLs. The test problems are based on assuming the same failure properties for all links, which results in problems that have the desirable properties of fully exercising the numerical integration procedures required in the evaluation of PLOAS and also possessing simple algebraic representations for PLOAS that can be used for verification of the analysis.

  17. Multi-level slug tests in highly permeable formations: 2. Hydraulic conductivity identification, method verification, and field applications

    Science.gov (United States)

    Zlotnik, V.A.; McGuire, V.L.

    1998-01-01

    Using the developed theory and modified Springer-Gelhar (SG) model, an identification method is proposed for estimating hydraulic conductivity from multi-level slug tests. The computerized algorithm calculates hydraulic conductivity from both monotonic and oscillatory well responses obtained using a double-packer system. Field verification of the method was performed at a specially designed fully penetrating well of 0.1-m diameter with a 10-m screen in a sand and gravel alluvial aquifer (MSEA site, Shelton, Nebraska). During well installation, disturbed core samples were collected every 0.6 m using a split-spoon sampler. Vertical profiles of hydraulic conductivity were produced on the basis of grain-size analysis of the disturbed core samples. These results closely correlate with the vertical profile of horizontal hydraulic conductivity obtained by interpreting multi-level slug test responses using the modified SG model. The identification method was applied to interpret the response from 474 slug tests in 156 locations at the MSEA site. More than 60% of responses were oscillatory. The method produced a good match to experimental data for both oscillatory and monotonic responses using an automated curve matching procedure. The proposed method allowed us to drastically increase the efficiency of each well used for aquifer characterization and to process massive arrays of field data. Recommendations generalizing this experience to massive application of the proposed method are developed.Using the developed theory and modified Springer-Gelhar (SG) model, an identification method is proposed for estimating hydraulic conductivity from multi-level slug tests. The computerized algorithm calculates hydraulic conductivity from both monotonic and oscillatory well responses obtained using a double-packer system. Field verification of the method was performed at a specially designed fully penetrating well of 0.1-m diameter with a 10-m screen in a sand and gravel alluvial

  18. Performance of multihundred-watt fueled-sphere assemblies in the safety verification test

    International Nuclear Information System (INIS)

    Cramer, E.M.

    1975-09-01

    Seven fueled-sphere assemblies equivalent to those proposed for use in multihundred-watt thermoelectric generators were subjected to conditions that simulated the sequential environments produced by an orbital abort and earth impact. The procedures were similar to those in the Safety Sequential Test, and the assemblies differed only in minor dimensional and power level changes. All assemblies met the specifications for flight quality units. Visual examination indicated that all the iridium shells had lost their containment capability; however, rupturing of two shells was not confirmed. Five were obviously ruptured, and the fuel in three was exposed. All iridium fractures were essentially intergranular. A large grain size may have promoted this type of failure. Half of the vent assemblies failed to pass helium at ambient temperature after the test. Failure was because of nonmetallic materials in the vent frits. Release of plutonia per unit area of cracks in a containment shell ruptured by simulated earth impact was determined

  19. Relative Navigation Light Detection and Ranging (LIDAR) Sensor Development Test Objective (DTO) Performance Verification

    Science.gov (United States)

    Dennehy, Cornelius J.

    2013-01-01

    The NASA Engineering and Safety Center (NESC) received a request from the NASA Associate Administrator (AA) for Human Exploration and Operations Mission Directorate (HEOMD), to quantitatively evaluate the individual performance of three light detection and ranging (LIDAR) rendezvous sensors flown as orbiter's development test objective on Space Transportation System (STS)-127, STS-133, STS-134, and STS-135. This document contains the outcome of the NESC assessment.

  20. Verification of dissolution test for doxycycline hyclate in capsules to implement into the pharmacopoeial monograph

    OpenAIRE

    Dobrova, Anna; Golovchenko, Olga; Georgiyants, Victoria

    2018-01-01

    The study of dissolution profiles is important as a cheap and easy supplement to bioequivalence research, and as a variation to such studies. This method is not outlined in the State Pharmacopoeia of Ukraine for the doxycycline capsules. Therefore, according to the current requirements, it was necessary to verify the procedure recommended by the US Pharmacopeia to confirm that this laboratory test will be reproduced correctly, and to use it in our further studies.The aim of our research was t...

  1. Performance test and verification of an off-the-shelf automated avian radar tracking system.

    Science.gov (United States)

    May, Roel; Steinheim, Yngve; Kvaløy, Pål; Vang, Roald; Hanssen, Frank

    2017-08-01

    Microwave radar is an important tool for observation of birds in flight and represents a tremendous increase in observation capability in terms of amount of surveillance space that can be covered at relatively low cost. Based on off-the-shelf radar hardware, automated radar tracking systems have been developed for monitoring avian movements. However, radar used as an observation instrument in biological research has its limitations that are important to be aware of when analyzing recorded radar data. This article describes a method for exploring the detection capabilities of a dedicated short-range avian radar system used inside the operational Smøla wind-power plant. The purpose of the testing described was to find the maximum detection range for various sized birds, while controlling for the effects of flight tortuosity, flight orientation relative to the radar and ground clutter. The method was to use a dedicated test target in form of a remotely controlled unmanned aerial vehicle (UAV) with calibrated radar cross section (RCS), which enabled the design of virtually any test flight pattern within the area of interest. The UAV had a detection probability of 0.5 within a range of 2,340 m from the radar. The detection performance obtained by the RCS-calibrated test target (-11 dBm 2 , 0.08 m 2 RCS) was then extrapolated to find the corresponding performance of differently sized birds. Detection range depends on system sensitivity, the environment within which the radar is placed and the spatial distribution of birds. The avian radar under study enables continuous monitoring of bird activity within a maximum range up to 2 km dependent on the size of the birds in question. While small bird species may be detected up to 0.5-1 km, larger species may be detected up to 1.5-2 km distance from the radar.

  2. Review of waste package verification tests. Semiannual report, April 1985-September 1985

    International Nuclear Information System (INIS)

    Soo, P.

    1986-01-01

    Several studies were completed this period to evaluate experimental and analytical methodologies being used in the DOE waste package program. The first involves a determination of the relevance of the test conditions being used by DOE to characterize waste package component behavior in a salt repository system. Another study focuses on the testing conditions and procedures used to measure radionuclide solubility and colloid formation in repository groundwaters. An attempt was also made to evaluate the adequacy of selected waste package performance codes. However, the latter work was limited by an inability to obtain several codes from DOE. Nevertheless, it was possible to comment briefly on the structures and intents of the codes based on publications in the open literature. The final study involved an experimental program to determine the likelihood of stress-corrosion cracking of austenitic stainless steels and Incoloy 825 in simulated tuff repository environments. Tests for six-month exposure periods in water and air-steam conditions are described. 52 figs., 48 tabs

  3. Hypervelocity technology carbon/carbon testing

    Science.gov (United States)

    Anselmo, John V.; Kretz, Lawrence O.

    The paper describes the procedures used at the Structures Test Laboratory of the Wright Laboratory's Flight Dynamics Directorate to test a carbon/carbon hot structure representing a typical hypersonic gliding body, and presents the results of tests. The forebody was heated to 1371 C over 13 test runs, using radiant quartz lamps; a vertical shear force of 5.34 kN was introduced to the nose at a stabilized temperature of 816 C. Test data were collected using prototype high-temperature strain gages, in-house-designed high-temperature extensometers, conventional strain gages, and thermocouples. Video footage was taken of all test runs. Test runs were successfully completed up to 1371 C with flight typical thermal gradients at heating rates up to 5.56 C/sec. Results showed that, overall, the termal test control systems performed as predicted and that test temperatures and thermal gradients were achieved to within about 5 percent in most cases.

  4. Selection of a leaching test method for waste product conformity verification

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Isabel Sofia R.F.S.; Tello, Clédola Cássia O.; Haucz, Maria Judite A., E-mail: isabel.lopes@cdtn.br, E-mail: tellocc@cdtn.br, E-mail: hauczmj@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    A study on the waste acceptance criteria (WAC) for disposal in a near-surface repository is being implemented by CDTN / CNEN. The acceptance criteria are used to ensure the safety in the repository facility in order to protect the employees, the public and the environment from some possible harmful and dangerous effects of the ionizing radiation. A near-surface repository is intended to be built for disposal of the Brazilian low- and intermediate level wastes. Leaching was the criterion chosen to be studied in this research. It is extremely important for the safety assessment to evaluate the waste form in relation to the radionuclides release, to predict the repository performance in the long term. As in the Brazilian WAC the test to measure the radionuclides leaching is not defined yet, two leaching tests were selected to be performed, the ISO 6961 and the ASTM C1308. The results will be analyzed in order to verify their similarities and differences and also their advantages and disadvantages. Inactive tracers cesium and lead were used as tracers to follow the leaching in both procedures. (author)

  5. Selection of a leaching test method for waste product conformity verification

    International Nuclear Information System (INIS)

    Lopes, Isabel Sofia R.F.S.; Tello, Clédola Cássia O.; Haucz, Maria Judite A.

    2017-01-01

    A study on the waste acceptance criteria (WAC) for disposal in a near-surface repository is being implemented by CDTN / CNEN. The acceptance criteria are used to ensure the safety in the repository facility in order to protect the employees, the public and the environment from some possible harmful and dangerous effects of the ionizing radiation. A near-surface repository is intended to be built for disposal of the Brazilian low- and intermediate level wastes. Leaching was the criterion chosen to be studied in this research. It is extremely important for the safety assessment to evaluate the waste form in relation to the radionuclides release, to predict the repository performance in the long term. As in the Brazilian WAC the test to measure the radionuclides leaching is not defined yet, two leaching tests were selected to be performed, the ISO 6961 and the ASTM C1308. The results will be analyzed in order to verify their similarities and differences and also their advantages and disadvantages. Inactive tracers cesium and lead were used as tracers to follow the leaching in both procedures. (author)

  6. Radball Technology Testing For Hot Cell Characterization

    International Nuclear Information System (INIS)

    Farfan, E.; Jannik, T.

    2010-01-01

    Operations at various U.S. Department of Energy sites have resulted in substantial radiological contamination of tools, equipment, and facilities. It is essential to use remote technologies for characterization and decommissioning to keep worker exposures as low as reasonably achievable in these highly contaminated environments. A significant initial step in planning and implementing D and D of contaminated facilities involves the development of an accurate assessment of the radiological, chemical, and structural conditions inside of the facilities. Collected information describing facility conditions using remote technologies could reduce the conservatism associated with planning initial worker entry (and associated cost).

  7. FFTF [fast flux tests facility] metal fuel pin sodium bond quality verification

    International Nuclear Information System (INIS)

    Pitner, A.L.

    1989-01-01

    The Fast Flux Tests Facility (FFTF) Series III driver fuel design consists of U-10 Zr fuel slugs contained in a ferritic alloy cladding. A liquid-metal, sodium bond between the fuel and cladding is required to prevent unacceptable temperatures during operation. Excessive voiding or porosity in the sodium thermal bond could result in localized fuel melting during irradiation. It is therefore imperative that bond quality be verified during fabrication of these metal fuel pins prior to irradiation. Cladding stripping of two spare metal fuel pins was successfully performed to inspect the quality of the sodium thermal bond and to compare observed defects in the bond with eddy current measurements. Bond quality was found to be generally good, thereby confirming the fabrication process used to bond the fuel and cladding with liquid-metal sodium to be acceptable. Observed porosity distribution in the sodium bond correlated well with eddy current indications

  8. Verification test for helium panel of cryopump for DIII-D advanced divertor

    Energy Technology Data Exchange (ETDEWEB)

    Baxi, C.B.; Laughon, G.J.; Langhorn, A.R.; Schaubel, K.M.; Smith, J.P.; Gootgeld, A.M.; Campbell, G.L. (General Atomics, San Diego, CA (United States)); Menon, M.M. (Oak Ridge National Lab., TN (United States))

    1991-10-01

    It is planned to install a cryogenic pump in the lower divertor portion of the D3-D tokamak with a pumping speed of 50000{ell}/s and an exhaust of 2670 Pa-{ell}/s (20 Torr-{ell}s). A coaxial counter flow configuration has been chosen for the helium panel of this cryogenic pump. This paper evaluates cooldown rates and fluid stability of this configuration. A prototypic test was performed at General Atomics (GA) to increase confidence in the design. It was concluded that the helium panel cooldown rate agreed quite well with analytical prediction and was within acceptable limits. The design flow rate proved stable and two-phase pressure drop can be predicted quite accurately. 8 refs., 5 figs., 1 tab.

  9. Integrated Mecical Model (IMM) 4.0 Verification and Validation (VV) Testing (HRP IWS 2016)

    Science.gov (United States)

    Walton, M; Kerstman, E.; Arellano, J.; Boley, L.; Reyes, D.; Young, M.; Garcia, Y.; Saile, L.; Myers, J.

    2016-01-01

    Timeline, partial treatment, and alternate medications were added to the IMM to improve the fidelity of this model to enhance decision support capabilities. Using standard design reference missions, IMM VV testing compared outputs from the current operational IMM (v3) with those from the model with added functionalities (v4). These new capabilities were examined in a comparative, stepwise approach as follows: a) comparison of the current operational IMM v3 with the enhanced functionality of timeline alone (IMM 4.T), b) comparison of IMM 4.T with the timeline and partial treatment (IMM 4.TPT), and c) comparison of IMM 4.TPT with timeline, partial treatment and alternative medication (IMM 4.0).

  10. Creep crack growth verification testing in alloy 800H tubular components

    International Nuclear Information System (INIS)

    Hunter, C.P.; Hurst, R.C.

    1992-01-01

    A method for determining the creep crack growth, CCG, and stress rupture behaviour of Alloy 800H tubular components containing longitudinal notches at 800deg C is described. The presence of the notch is found to systematically weaken the tube, the degree of weaking dependent upon the notch length and depth. The creep crack growth rates, determined from a specially adapted potential drop technique are compared with those obtained from conventional compact tension type specimens. Using the stress intensity factor, K 1 , and the C * parameter as the basis of comparison it is found that the latter gives excellent correlation between the specimen and component behaviour. Finally attention is drawn to the potential dangers of predicting the component creep crack growth behaviour from the data obtained using conventional specimens for a structure sensitive material such as Alloy 800H and conversely to the advantages of the component type CCG tests developed in the present work. (orig.)

  11. Verification of maximum impact force for interim storage cask for the Fast Flux Testing Facility

    International Nuclear Information System (INIS)

    Chen, W.W.; Chang, S.J.

    1996-01-01

    The objective of this paper is to perform an impact analysis of the Interim Storage Cask (ISC) of the Fast Flux Test Facility (FFTF) for a 4-ft end drop. The ISC is a concrete cask used to store spent nuclear fuels. The analysis is to justify the impact force calculated by General Atomics (General Atomics, 1994) using the ILMOD computer code. ILMOD determines the maximum force developed by the concrete crushing which occurs when the drop energy has been absorbed. The maximum force, multiplied by the dynamic load factor (DLF), was used to determine the maximum g-level on the cask during a 4-ft end drop accident onto the heavily reinforced FFTF Reactor Service Building's concrete surface. For the analysis, this surface was assumed to be unyielding and the cask absorbed all the drop energy. This conservative assumption simplified the modeling used to qualify the cask's structural integrity for this accident condition

  12. PROOF OF CONCEPT TEST OF A UNIQUE GASEOUS PERFLUROCARBON TRACER SYSTEM FOR VERIFICATION AND LONG TERM MONITORING OF CAPS AND COVER SYSTEMS CONDUCTED AT THE SAVANNAH RIVER SITE BENTONITE MAT TEST FACILITY.

    Energy Technology Data Exchange (ETDEWEB)

    HEISER,J.; SULLIVAN,T.; SERRATO,M.

    2002-02-24

    be used as a non-invasive method (if injection ports are emplaced prior to cover emplacement) on new covers or a minimally invasive method on existing covers. PFT verification will be useful at all buried waste sites using a cover system (e.g., treated or untreated chemical waste landfills) including DOE, commercial, and private sector sites. This paper discusses the initial field trial of the PFT cover monitoring system performed at the Savannah River Site (SRS) in FY01. The experiments provided a successful proof-of-principle test of the PFT technology in monitoring caps and covers. An injection and sampling array was installed in the Bentomat test cap at the SRS Caps Test Facility. This system contained 6 feet of sandy soil beneath a 1/2 inch geosynthetic clay liner covered by an HDPE liner which was covered by 2 feet of clayey top soil. PFTs were injected into the sandy soil though a pre-existing system of access pipes below the cap and soil gas samples were taken on top of the cap. Mid-way into the injection period a series of 1 1/2 inch holes were punched into the cap (through the geomembrane) to provide a positive breach in the cap. Data will be presented that shows the initial cap was fairly tight and leak free and that the artificially induced leaks were detectable within two hours of occurrence.

  13. Verification of a TRACE EPRTM model on the basis of a scaling calculation of an SBLOCA ROSA test

    International Nuclear Information System (INIS)

    Freixa, J.; Manera, A.

    2011-01-01

    Research highlights: → Verification of a TRACE input deck for the EPR TM generation III PWR. → Scaling simulation of an SBLOCA experiment of the integral test facility ROSA/LSTF. → The EPR TM model was compared with the TRACE results of the ROSA/LSTF model. - Abstract: In cooperation with the Finnish Radiation and Nuclear Safety Authority (STUK), a project has been launched at the Paul Scherrer Institute (PSI) aimed at performing safety evaluations of the Olkiluoto-3 nuclear power plant (NPP), the first EPR TM , a generation III pressurizer water reactor (PWR); with particular emphasis on small-and large-break loss-of-coolant-accidents (SB/LB-LOCAs) and main steam-line breaks. As a first step of this work, the best estimate system code TRACE has been used to develop a model of Olkiluoto-3. In order to test the nodalization, a scaling calculation from the rig of safety assessment (ROSA) test facility has been performed. The ROSA large scale test facility (LSTF) was built to simulate Westinghouse design pressurized water reactors (PWR) with a four-loop configuration. Even though there are differences between the EPR TM and the Westinghouse designs, the number of similarities is large enough to carry out scaling calculations on SBLOCA and LOCA cases from the ROSA facility; as a matter of fact, the main differences are located in the secondary side. Test 6-1 of the ROSA 1 programme, an SBLOCA with the break situated in the upper head of the reactor pressure vessel (RPV), was of special interest since a very good agreement with the experiment was obtained with a TRACE input deck. In order to perform such scaling calculation, the set-points of the secondary relief and safety valves in the EPR TM nodalization had to be changed to those used in the ROSA facility, the break size and the core power had to be scaled by a factor of 60 (according to the core power and core volume) and the pumps coast down had to be adapted to the ones of the test. The calculation showed

  14. ON-LINE MONITORING OF I&C TRANSMITTERS AND SENSORS FOR CALIBRATION VERIFICATION AND RESPONSE TIME TESTING WAS SUCCESSFULLY IMPLEMENTED AT ATR

    Energy Technology Data Exchange (ETDEWEB)

    Erickson, Phillip A.; O' Hagan, Ryan; Shumaker, Brent; Hashemian, H. M.

    2017-03-01

    The Advanced Test Reactor (ATR) has always had a comprehensive procedure to verify the performance of its critical transmitters and sensors, including RTDs, and pressure, level, and flow transmitters. These transmitters and sensors have been periodically tested for response time and calibration verification to ensure accuracy. With implementation of online monitoring techniques at ATR, the calibration verification and response time testing of these transmitters and sensors are verified remotely, automatically, hands off, include more portions of the system, and can be performed at almost any time during process operations. The work was done under a DOE funded SBIR project carried out by AMS. As a result, ATR is now able to save the manpower that has been spent over the years on manual calibration verification and response time testing of its temperature and pressure sensors and refocus those resources towards more equipment reliability needs. More importantly, implementation of OLM will help enhance the overall availability, safety, and efficiency. Together with equipment reliability programs of ATR, the integration of OLM will also help with I&C aging management goals of the Department of Energy and long-time operation of ATR.

  15. Verification study on technology for preliminary investigation for HLW geological disposal. Part 2. Verification of surface geophysical prospecting through establishing site descriptive models

    International Nuclear Information System (INIS)

    Kondo, Hirofumi; Suzuki, Koichi; Hasegawa, Takuma; Goto, Keiichiro; Yoshimura, Kimitaka; Muramoto, Shigenori

    2012-01-01

    The Yokosuka demonstration and validation project using Yokosuka CRIEPI site has been conducted since FY 2006 as a cooperative research between NUMO (Nuclear Waste Management Organization of Japan) and CRIEPI. The objectives of this project are to examine and to refine the basic methodology of the investigation and assessment of properties of geological environment in the stage of Preliminary Investigation for HLW geological disposal. Within Preliminary Investigation technologies, surface geophysical prospecting is an important means of obtaining information from deep geological environment for planning borehole surveys. In FY 2010, both seismic prospecting (seismic reflection and vertical seismic profiling methods) for obtaining information about geological structure and electromagnetic prospecting (magneto-telluric and time domain electromagnetic methods) for obtaining information about resistivity structure reflecting the distribution of salt water/fresh water boundary to a depth of over several hundred meters were conducted in the Yokosuka CRIEPI site. Through these surveys, the contribution of geophysical prospecting methods in the surface survey stage to improving the reliability of site descriptive models was confirmed. (author)

  16. Nuclear disarmament verification

    Energy Technology Data Exchange (ETDEWEB)

    DeVolpi, A.

    1993-12-31

    Arms control treaties, unilateral actions, and cooperative activities -- reflecting the defusing of East-West tensions -- are causing nuclear weapons to be disarmed and dismantled worldwide. In order to provide for future reductions and to build confidence in the permanency of this disarmament, verification procedures and technologies would play an important role. This paper outlines arms-control objectives, treaty organization, and actions that could be undertaken. For the purposes of this Workshop on Verification, nuclear disarmament has been divided into five topical subareas: Converting nuclear-weapons production complexes, Eliminating and monitoring nuclear-weapons delivery systems, Disabling and destroying nuclear warheads, Demilitarizing or non-military utilization of special nuclear materials, and Inhibiting nuclear arms in non-nuclear-weapons states. This paper concludes with an overview of potential methods for verification.

  17. Nuclear disarmament verification

    International Nuclear Information System (INIS)

    DeVolpi, A.

    1993-01-01

    Arms control treaties, unilateral actions, and cooperative activities -- reflecting the defusing of East-West tensions -- are causing nuclear weapons to be disarmed and dismantled worldwide. In order to provide for future reductions and to build confidence in the permanency of this disarmament, verification procedures and technologies would play an important role. This paper outlines arms-control objectives, treaty organization, and actions that could be undertaken. For the purposes of this Workshop on Verification, nuclear disarmament has been divided into five topical subareas: Converting nuclear-weapons production complexes, Eliminating and monitoring nuclear-weapons delivery systems, Disabling and destroying nuclear warheads, Demilitarizing or non-military utilization of special nuclear materials, and Inhibiting nuclear arms in non-nuclear-weapons states. This paper concludes with an overview of potential methods for verification

  18. ITER: a technology test bed for a fusion reactor

    International Nuclear Information System (INIS)

    Huguet, M.; Green, B.J.

    1996-01-01

    The ITER Project aims to establish nuclear fusion as an energy source that has potential safety and environmental advantages, and to develop the technologies required for a fusion reactor. ITER is a collaborative project between the European Union, Japan, the Russian Federation and the United States of America. During the current phase of the Project, an R and D programme of about 850 million dollars is underway to develop the technologies required for ITER. This technological effort should culminate in the construction of the components and systems of the ITER machine and its auxiliaries. The main areas of technological development include the first wall and divertor technology, the blanket technology and tritium breeding, superconducting magnet technology, pulsed power technology and remote handling. ITER is a test bed and an essential step to establish the technology of future fusion reactors. Many of the ITER technologies are of potential interest to other fields and their development is expected to benefit the industries involved. (author)

  19. Verification Tests and Insulation Design Method of Cold Dielectric Superconducting Cable

    Science.gov (United States)

    Suzuki, Hiroshi; Takahashi, Toshihiro; Okamoto, Tatsuki; Ishii, Noboru; Mukoyama, Shin-Ichi; Kimura, Akio

    A High Temperature Superconducting (HTS) cable has a bulk power transmission capacity as a candidate for the replacement of the aged cable and/or for the increase of the power transmission capacity, and its diameter is prefer to be smaller than inner diameter of the duct for the existing cables. To reduce the diameter of HTS cable, the cold dielectric (CD) type electrical insulation in which a cable core is immersed into liquid nitrogen (LN2) should be adopted, and the thickness of its electrical insulation layer has to be optimized. Since a partial discharge (PD) in the electrical insulation layer of the CD type HTS cable is considered as a major causes for the aging of the insulation layer, PD-free design must be adopted for the CD type HTS cable. This paper describes a design method for the electrical insulation layer of the CD type HTS cable adopting the PD-free design under ac stress, based on the experimental results such as a PD inception stress (PDIE), an impulse breakdown stress, and PD extinction characteristics under ac stress superimposed with an impulse stress. Moreover, the proposed design method was applied to a 500-m HTS cable and was verified by a field test.

  20. [Verification of the double dissociation model of shyness using the implicit association test].

    Science.gov (United States)

    Fujii, Tsutomu; Aikawa, Atsushi

    2013-12-01

    The "double dissociation model" of shyness proposed by Asendorpf, Banse, and Mtücke (2002) was demonstrated in Japan by Aikawa and Fujii (2011). However, the generalizability of the double dissociation model of shyness was uncertain. The present study examined whether the results reported in Aikawa and Fujii (2011) would be replicated. In Study 1, college students (n = 91) completed explicit self-ratings of shyness and other personality scales. In Study 2, forty-eight participants completed IAT (Implicit Association Test) for shyness, and their friends (n = 141) rated those participants on various personality scales. The results revealed that only the explicit self-concept ratings predicted other-rated low praise-seeking behavior, sociable behavior and high rejection-avoidance behavior (controlled shy behavior). Only the implicit self-concept measured by the shyness IAT predicted other-rated high interpersonal tension (spontaneous shy behavior). The results of this study are similar to the findings of the previous research, which supports generalizability of the double dissociation model of shyness.

  1. Formal Methods Specification and Verification Guidebook for Software and Computer Systems. Volume 1; Planning and Technology Insertion

    Science.gov (United States)

    1995-01-01

    The Formal Methods Specification and Verification Guidebook for Software and Computer Systems describes a set of techniques called Formal Methods (FM), and outlines their use in the specification and verification of computer systems and software. Development of increasingly complex systems has created a need for improved specification and verification techniques. NASA's Safety and Mission Quality Office has supported the investigation of techniques such as FM, which are now an accepted method for enhancing the quality of aerospace applications. The guidebook provides information for managers and practitioners who are interested in integrating FM into an existing systems development process. Information includes technical and administrative considerations that must be addressed when establishing the use of FM on a specific project. The guidebook is intended to aid decision makers in the successful application of FM to the development of high-quality systems at reasonable cost. This is the first volume of a planned two-volume set. The current volume focuses on administrative and planning considerations for the successful application of FM.

  2. Application of the microcapsule fabrication technology to magnetic particle testing

    International Nuclear Information System (INIS)

    Ito, Fuyumi; Nishimura, Akihiko; Norimatsu, Takayoshi; Nagai, Keiji

    2010-01-01

    The purpose of the research is to apply the micro capsule technology to the facility maintenance. The micro capsule technology for laser fusion target was developed at the Institute of Laser Engineering Osaka University. We have a plan to apply the fabrication technology of polystyrene micro capsules to the facility maintenance where the magnetic particle testing for complex piping system is investigated. (author)

  3. Verification of a Proposed Clinical Electroacoustic Test Protocol for Personal Digital Modulation Receivers Coupled to Cochlear Implant Sound Processors.

    Science.gov (United States)

    Nair, Erika L; Sousa, Rhonda; Wannagot, Shannon

    Guidelines established by the AAA currently recommend behavioral testing when fitting frequency modulated (FM) systems to individuals with cochlear implants (CIs). A protocol for completing electroacoustic measures has not yet been validated for personal FM systems or digital modulation (DM) systems coupled to CI sound processors. In response, some professionals have used or altered the AAA electroacoustic verification steps for fitting FM systems to hearing aids when fitting FM systems to CI sound processors. More recently steps were outlined in a proposed protocol. The purpose of this research is to review and compare the electroacoustic test measures outlined in a 2013 article by Schafer and colleagues in the Journal of the American Academy of Audiology titled "A Proposed Electroacoustic Test Protocol for Personal FM Receivers Coupled to Cochlear Implant Sound Processors" to the AAA electroacoustic verification steps for fitting FM systems to hearing aids when fitting DM systems to CI users. Electroacoustic measures were conducted on 71 CI sound processors and Phonak Roger DM systems using a proposed protocol and an adapted AAA protocol. Phonak's recommended default receiver gain setting was used for each CI sound processor manufacturer and adjusted if necessary to achieve transparency. Electroacoustic measures were conducted on Cochlear and Advanced Bionics (AB) sound processors. In this study, 28 Cochlear Nucleus 5/CP810 sound processors, 26 Cochlear Nucleus 6/CP910 sound processors, and 17 AB Naida CI Q70 sound processors were coupled in various combinations to Phonak Roger DM dedicated receivers (25 Phonak Roger 14 receivers-Cochlear dedicated receiver-and 9 Phonak Roger 17 receivers-AB dedicated receiver) and 20 Phonak Roger Inspiro transmitters. Employing both the AAA and the Schafer et al protocols, electroacoustic measurements were conducted with the Audioscan Verifit in a clinical setting on 71 CI sound processors and Phonak Roger DM systems to

  4. Development of an Autonomous Navigation Technology Test Vehicle

    National Research Council Canada - National Science Library

    Tobler, Chad K

    2004-01-01

    .... In order to continue these research activities at CIMAR, a new Kawasaki Mule All-Terrain Vehicle was chosen to be automated as a test-bed for the purpose of developing and testing autonomous vehicle technologies...

  5. Laboratory Testing and Performance Verification of the CHARIS Integral Field Spectrograph

    Science.gov (United States)

    Groff, Tyler D.; Chilcote, Jeffrey; Kasdin, N. Jeremy; Galvin, Michael; Loomis, Craig; Carr, Michael A.; Brandt, Timothy; Knapp, Gillian; Limbach, Mary Anne; Guyon, Olivier; hide

    2016-01-01

    delivered to the Subaru telescope in April 2016. This paper is a report on the laboratory performance of the spectrograph, and its current status in the commissioning process so that observers will better understand the instrument capabilities. We will also discuss the lessons learned during the testing process and their impact on future high-contrast imaging spectrographs for wavefront control.

  6. PCR-based verification of positive rapid diagnostic tests for intestinal protozoa infections with variable test band intensity.

    Science.gov (United States)

    Becker, Sören L; Müller, Ivan; Mertens, Pascal; Herrmann, Mathias; Zondie, Leyli; Beyleveld, Lindsey; Gerber, Markus; du Randt, Rosa; Pühse, Uwe; Walter, Cheryl; Utzinger, Jürg

    2017-10-01

    Stool-based rapid diagnostic tests (RDTs) for pathogenic intestinal protozoa (e.g. Cryptosporidium spp. and Giardia intestinalis) allow for prompt diagnosis and treatment in resource-constrained settings. Such RDTs can improve individual patient management and facilitate population-based screening programmes in areas without microbiological laboratories for confirmatory testing. However, RDTs are difficult to interpret in case of 'trace' results with faint test band intensities and little is known about whether such ambiguous results might indicate 'true' infections. In a longitudinal study conducted in poor neighbourhoods of Port Elizabeth, South Africa, a total of 1428 stool samples from two cohorts of schoolchildren were examined on the spot for Cryptosporidium spp. and G. intestinalis using an RDT (Crypto/Giardia DuoStrip; Coris BioConcept). Overall, 121 samples were positive for G. intestinalis and the RDT suggested presence of cryptosporidiosis in 22 samples. After a storage period of 9-10 months in cohort 1 and 2-3 months in cohort 2, samples were subjected to multiplex PCR (BD Max™ Enteric Parasite Panel, Becton Dickinson). Ninety-three percent (112/121) of RDT-positive samples for G. intestinalis were confirmed by PCR, with a correlation between RDT test band intensity and quantitative pathogen load present in the sample. For Cryptosporidium spp., all positive RDTs had faintly visible lines and these were negative on PCR. The performance of the BD Max™ PCR was nearly identical in both cohorts, despite the prolonged storage at disrupted cold chain conditions in cohort 1. The Crypto/Giardia DuoStrip warrants further validation in communities with a high incidence of diarrhoea. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Verification and Validation of the PLTEMP/ANL Code for Thermal-Hydraulic Analysis of Experimental and Test Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Kalimullah, M. [Argonne National Lab. (ANL), Argonne, IL (United States); Olson, Arne P. [Argonne National Lab. (ANL), Argonne, IL (United States); Feldman, E. E. [Argonne National Lab. (ANL), Argonne, IL (United States); Hanan, N. [Argonne National Lab. (ANL), Argonne, IL (United States); Dionne, B. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-04-07

    The document compiles in a single volume several verification and validation works done for the PLTEMP/ANL code during the years of its development and improvement. Some works that are available in the open literature are simply referenced at the outset, and are not included in the document. PLTEMP has been used in conversion safety analysis reports of several US and foreign research reactors that have been licensed and converted. A list of such reactors is given. Each chapter of the document deals with the verification or validation of a specific model. The model verification is usually done by comparing the code with hand calculation, Microsoft spreadsheet calculation, or Mathematica calculation. The model validation is done by comparing the code with experimental data or a more validated code like the RELAP5 code.

  8. 78 FR 23574 - Public Workshop on Marine Technology and Standards

    Science.gov (United States)

    2013-04-19

    ... Material Bilgewater Monitoring Using Advanced Light Scattering Technology Vortex Induced Vibration Design... Verification of Energy Efficiency Design Index Testing and Approval of Ballast Water Treatment Systems... Technology and Standards AGENCY: Coast Guard, DHS. ACTION: Notice. SUMMARY: The American Society of...

  9. MSAP Hardware Verification: Testing Multi-Mission System Architecture Platform Hardware Using Simulation and Bench Test Equipment

    Science.gov (United States)

    Crossin, Kent R.

    2005-01-01

    The Multi-Mission System Architecture Platform (MSAP) project aims to develop a system of hardware and software that will provide the core functionality necessary in many JPL missions and can be tailored to accommodate mission-specific requirements. The MSAP flight hardware is being developed in the Verilog hardware description language, allowing developers to simulate their design before releasing it to a field programmable gate array (FPGA). FPGAs can be updated in a matter of minutes, drastically reducing the time and expense required to produce traditional application-specific integrated circuits. Bench test equipment connected to the FPGAs can then probe and run Tcl scripts on the hardware. The Verilog and Tcl code can be reused or modified with each design. These steps are effective in confirming that the design operates according specifications.

  10. NEUTRON ALGORITHM VERIFICATION TESTING

    Energy Technology Data Exchange (ETDEWEB)

    COWGILL,M.; MOSBY,W.; ARGONNE NATIONAL LABORATORY-WEST

    2000-07-19

    Active well coincidence counter assays have been performed on uranium metal highly enriched in {sup 235}U. The data obtained in the present program, together with highly enriched uranium (HEU) metal data obtained in other programs, have been analyzed using two approaches, the standard approach and an alternative approach developed at BNL. Analysis of the data with the standard approach revealed that the form of the relationship between the measured reals and the {sup 235}U mass varied, being sometimes linear and sometimes a second-order polynomial. In contrast, application of the BNL algorithm, which takes into consideration the totals, consistently yielded linear relationships between the totals-corrected reals and the {sup 235}U mass. The constants in these linear relationships varied with geometric configuration and level of enrichment. This indicates that, when the BNL algorithm is used, calibration curves can be established with fewer data points and with more certainty than if a standard algorithm is used. However, this potential advantage has only been established for assays of HEU metal. In addition, the method is sensitive to the stability of natural background in the measurement facility.

  11. Provenance testing at Michigan Technological University

    Science.gov (United States)

    Robert L. Sajdak

    1970-01-01

    The location of M.T.U. in the Keweenaw Peninsula of Upper Michigan provides some unique advantages and disadvantages in provenance testing and tree improvement research. Extremes in summer and winter temperatures are uncommon because of the moderating effect of Lake Superior. Near the Lake we have about 140 frost-free days while inland the frost-free season is only 80...

  12. [Application of terahertz technology in medical testing and diagnosis].

    Science.gov (United States)

    Qi, Na; Zhang, Zhuo-Yong; Xiang, Yu-Hong

    2013-08-01

    Terahertz science and technology is increasingly emphasized in science and industry, and has progressed significantly in recent years. There is an important aspect of attention in the application of terahertz technology to medicine. The overview of the terahertz characters, terahertz spectroscopy and terahertz imaging technology is introduced. This paper focuses on reviewing the use of and research progress in terahertz spectroscopy and terahertz imaging technology in medical testing and diagnosis. Furthermore, the problems to be solved and development directions of terahertz spectroscopy and terahertz imaging technology are discussed.

  13. Plan for a laser weapon verification research program

    Energy Technology Data Exchange (ETDEWEB)

    Karr, T.J.

    1990-03-01

    Currently there is great interest in the question of how, or even whether, a treaty limiting the development and deployment of laser weapons could be verified. The concept of cooperative laser weapon verification is that each party would place monitoring stations near the other party's declared or suspect laser weapon facilities. The monitoring stations would measure the primary laser observables'' such as power or energy, either directly or by collecting laser radiation scattered from the air or the target, and would verify that the laser is operated within treaty limits. This concept is modeled along the lines of the seismic network recently activated in the USSR as a joint project of the United States Geologic Survey and the Soviet Academy of Sciences. The seismic data, gathered cooperatively, can be used by each party as it wishes, including to support verification of future nuclear test ban treaties. For laser weapon verification the monitoring stations are envisioned as ground-based, and would verify treaty limitations on ground-based laser anti-satellite (ASAT) weapons and on the ground-based development of other laser weapons. They would also contribute to verification of limitations on air-, sea- and space-based laser weapons, and the technology developed for cooperative verification could also be used in national technical means of verification. 2 figs., 4 tabs.

  14. Field test of short-notice random inspections for inventory-change verification at a low-enriched-uranium fuel-fabrication plant

    International Nuclear Information System (INIS)

    Fishbone, L.G.; Moussalli, G.; Naegele, G.

    1995-01-01

    An approach of short-notice random inspections (SNRIs) for inventory-change verification can enhance the effectiveness and efficiency of international safeguards at natural or low-enriched uranium (LEU) fuel fabrication plants. According to this approach, the plant operator declares the contents of nuclear material items before knowing if an inspection will occur to verify them. Additionally, items about which declarations are newly made should remain available for verification for an agreed time. Then a statistical inference can be made from verification results for items verified during SNRIs to the entire populations, i.e. the entire strata, even if inspectors were not present when many items were received or produced. A six-month field test of the feasibility of such SNRIs took place at the Westinghouse Electric Corporation Commercial Nuclear Fuel Division during 1993. Westinghouse personnel made daily declarations about both feed and product items, uranium hexafluoride cylinders and finished fuel assemblies, using a custom-designed computer ''mailbox''. Safeguards inspectors from the IAEA conducted eight SNRIs to verify these declarations. They arrived unannounced at the plant, in most cases immediately after travel from Canada, where the IAEA maintains a regional office. Items from both strata were verified during the SNRIs by meant of nondestructive assay equipment

  15. Review of Artificial Abrasion Test Methods for PV Module Technology

    Energy Technology Data Exchange (ETDEWEB)

    Miller, David C. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Muller, Matt T. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Simpson, Lin J. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-08-01

    This review is intended to identify the method or methods--and the basic details of those methods--that might be used to develop an artificial abrasion test. Methods used in the PV literature were compared with their closest implementation in existing standards. Also, meetings of the International PV Quality Assurance Task Force Task Group 12-3 (TG12-3, which is concerned with coated glass) were used to identify established test methods. Feedback from the group, which included many of the authors from the PV literature, included insights not explored within the literature itself. The combined experience and examples from the literature are intended to provide an assessment of the present industry practices and an informed path forward. Recommendations toward artificial abrasion test methods are then identified based on the experiences in the literature and feedback from the PV community. The review here is strictly focused on abrasion. Assessment methods, including optical performance (e.g., transmittance or reflectance), surface energy, and verification of chemical composition were not examined. Methods of artificially soiling PV modules or other specimens were not examined. The weathering of artificial or naturally soiled specimens (which may ultimately include combined temperature and humidity, thermal cycling and ultraviolet light) were also not examined. A sense of the purpose or application of an abrasion test method within the PV industry should, however, be evident from the literature.

  16. Sharing Year 2000 Testing Information on DOD Information Technology Systems

    National Research Council Canada - National Science Library

    1998-01-01

    The audit objective was to determine whether planning for year 2000 testing is adequate to ensure that mission critical DoD information technology systems will continue to operate properly after the year 2000...

  17. Testing for Nuclear Thermal Propulsion Systems: Identification of Technologies for Effluent Treatment in Test Facilities

    Data.gov (United States)

    National Aeronautics and Space Administration — Key steps to ensure identification of relevant effluent treatment technologies for Nuclear Thermal Propulsion (NTP) testing include the following. 1. Review of...

  18. A survey on the high reliability software verification and validation technology for instrumentation and control in NPP

    International Nuclear Information System (INIS)

    Kwon, Kee Choon; Lee, Chang Soo; Dong, In Sook

    1994-01-01

    This document presents the technical status of the software verification and validation (V and V) efforts to support developing and licensing digital instrumentation and control (I and C) systems in nuclear power plants. We have reviewed codes and standards to be concensus criteria among vendor, licensee and licenser. Then we have described the software licensing procedures under 10 CFR 50 and 10 CFR 52 of the United States cope with the licensing barrier. At last, we have surveyed the technical issues related to developing and licensing the high integrity software for digital I and C systems. These technical issues let us know the development direction of our own software V and V methodology. (Author) 13 refs., 2 figs.,

  19. Experimental inventory verification system

    International Nuclear Information System (INIS)

    Steverson, C.A.; Angerman, M.I.

    1991-01-01

    As Low As Reasonably Achievable (ALARA) goals and Department of Energy (DOE) inventory requirements are frequently in conflict at facilities across the DOE complex. The authors wish, on one hand, to verify the presence of correct amounts of nuclear materials that are in storage or in process; yet on the other hand, we wish to achieve ALARA goals by keeping individual and collective exposures as low as social, technical, economic, practical, and public policy considerations permit. The Experimental Inventory Verification System (EIVSystem) is a computer-based, camera-driven system that utilizes image processing technology to detect change in vault areas. Currently in the test and evaluation phase at Idaho National Engineering Laboratory, this system guards personnel. The EIVSystem continually monitors the vault, providing proof of changed status for objects sorted within the vault. This paper reports that these data could provide the basis for reducing inventory requirements when no change has occurred, thus helping implement ALARA policy; the data will also help describe there target area of an inventory when change has been shown to occur

  20. A 1:8.7 Scale Water Tunnel Verification & Validation Test of an Axial Flow Water Turbine

    Energy Technology Data Exchange (ETDEWEB)

    Fontaine, Arnold A. [Pennsylvania State Univ., University Park, PA (United States); Straka, William A. [Pennsylvania State Univ., University Park, PA (United States); Meyer, Richard S. [Pennsylvania State Univ., University Park, PA (United States); Jonson, Michael L. [Pennsylvania State Univ., University Park, PA (United States)

    2014-09-01

    As interest in waterpower technologies has increased over the last few years, there has been a growing need for a public database of measured data for these devices. This would provide a basic understanding of the technology and means to validate analytic and numerical models. Through collaboration between Sandia National Laboratories, Penn State University Applied Research Laboratory, and University of California, Davis, a new marine hydrokinetic turbine rotor was designed, fabricated at 1:8.7-scale, and experimentally tested to provide an open platform and dataset for further study and development. The water tunnel test of this three-bladed, horizontal-axis rotor recorded power production, blade loading, near-wake characterization, cavitation effects, and noise generation. This report documents the small-scale model test in detail and provides a brief discussion of the rotor design and an initial look at the results with comparison against low-order modeling tools. Detailed geometry and experimental measurements are released to Sandia National Laboratories as a data report addendum.

  1. CTBT integrated verification system evaluation model supplement

    Energy Technology Data Exchange (ETDEWEB)

    EDENBURN,MICHAEL W.; BUNTING,MARCUS; PAYNE JR.,ARTHUR C.; TROST,LAWRENCE C.

    2000-03-02

    Sandia National Laboratories has developed a computer based model called IVSEM (Integrated Verification System Evaluation Model) to estimate the performance of a nuclear detonation monitoring system. The IVSEM project was initiated in June 1994, by Sandia's Monitoring Systems and Technology Center and has been funded by the U.S. Department of Energy's Office of Nonproliferation and National Security (DOE/NN). IVSEM is a simple, ''top-level,'' modeling tool which estimates the performance of a Comprehensive Nuclear Test Ban Treaty (CTBT) monitoring system and can help explore the impact of various sensor system concepts and technology advancements on CTBT monitoring. One of IVSEM's unique features is that it integrates results from the various CTBT sensor technologies (seismic, in sound, radionuclide, and hydroacoustic) and allows the user to investigate synergy among the technologies. Specifically, IVSEM estimates the detection effectiveness (probability of detection), location accuracy, and identification capability of the integrated system and of each technology subsystem individually. The model attempts to accurately estimate the monitoring system's performance at medium interfaces (air-land, air-water) and for some evasive testing methods such as seismic decoupling. The original IVSEM report, CTBT Integrated Verification System Evaluation Model, SAND97-25 18, described version 1.2 of IVSEM. This report describes the changes made to IVSEM version 1.2 and the addition of identification capability estimates that have been incorporated into IVSEM version 2.0.

  2. CTBT integrated verification system evaluation model supplement

    International Nuclear Information System (INIS)

    EDENBURN, MICHAEL W.; BUNTING, MARCUS; PAYNE, ARTHUR C. JR.; TROST, LAWRENCE C.

    2000-01-01

    Sandia National Laboratories has developed a computer based model called IVSEM (Integrated Verification System Evaluation Model) to estimate the performance of a nuclear detonation monitoring system. The IVSEM project was initiated in June 1994, by Sandia's Monitoring Systems and Technology Center and has been funded by the U.S. Department of Energy's Office of Nonproliferation and National Security (DOE/NN). IVSEM is a simple, ''top-level,'' modeling tool which estimates the performance of a Comprehensive Nuclear Test Ban Treaty (CTBT) monitoring system and can help explore the impact of various sensor system concepts and technology advancements on CTBT monitoring. One of IVSEM's unique features is that it integrates results from the various CTBT sensor technologies (seismic, in sound, radionuclide, and hydroacoustic) and allows the user to investigate synergy among the technologies. Specifically, IVSEM estimates the detection effectiveness (probability of detection), location accuracy, and identification capability of the integrated system and of each technology subsystem individually. The model attempts to accurately estimate the monitoring system's performance at medium interfaces (air-land, air-water) and for some evasive testing methods such as seismic decoupling. The original IVSEM report, CTBT Integrated Verification System Evaluation Model, SAND97-25 18, described version 1.2 of IVSEM. This report describes the changes made to IVSEM version 1.2 and the addition of identification capability estimates that have been incorporated into IVSEM version 2.0

  3. Impact of changes in profile measurement technology on QA testing of pavement smoothness : technical report.

    Science.gov (United States)

    2013-03-01

    This project aims to establish the impact of recent changes in profiling technology on TxDOTs implementation of the Departments Item 585 and SP247-011 ride specifications. Of particular importance to this research is verification of the ride st...

  4. ETV Tech Brief: Rapid Fungi and Bacteria Detection Technologies

    Science.gov (United States)

    Technical brief that summarizes the results for Mycometer, Inc. Mycometer®-test and Bactiquant®-test, which are rapid detection technologies for fungi and bacteria. The brief summarizes the results of the verification report and statement.

  5. Systems Approach to Arms Control Verification

    Energy Technology Data Exchange (ETDEWEB)

    Allen, K; Neimeyer, I; Listner, C; Stein, G; Chen, C; Dreicer, M

    2015-05-15

    Using the decades of experience of developing concepts and technologies for verifying bilateral and multilateral arms control agreements, a broad conceptual systems approach is being developed that takes into account varying levels of information and risk. The IAEA has already demonstrated the applicability of a systems approach by implementing safeguards at the State level, with acquisition path analysis as the key element. In order to test whether such an approach could also be implemented for arms control verification, an exercise was conducted in November 2014 at the JRC ITU Ispra. Based on the scenario of a hypothetical treaty between two model nuclear weapons states aimed at capping their nuclear arsenals at existing levels, the goal of this exercise was to explore how to use acquisition path analysis in an arms control context. Our contribution will present the scenario, objectives and results of this exercise, and attempt to define future workshops aimed at further developing verification measures that will deter or detect treaty violations.

  6. PTC test bed upgrades to provide ACSES testing support capabilities at transportation technology center.

    Science.gov (United States)

    2015-06-01

    FRA Task Order 314 upgraded the Positive Train Control (PTC) Test Bed at the Transportation Technology Center to support : testing of PTC systems, components, and related equipment associated with the Advanced Civil Speed Enforcement System : (ACSES)...

  7. Development, evaluation and application of performance-based brake testing technologies field test : executive summary

    Science.gov (United States)

    1999-09-01

    This report presents the results of the field test portion of the Development, Evaluation, and Application of Performance-Based Brake Testing Technologies sponsored by the Federal Highway Administrations (FHWA) Office of Motor Carriers.

  8. Development of in-pile test and evaluation technology

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yung Hwan; Park, Jong Man; Joo, Kee Nam; Park, Duk Keun; Park, Se Jin; Oh, Jong Myung; Kim, Tae Ryong; Park Jin Suk; Lee, Jae Han [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-08-01

    To develop the in-pile test and evaluation technologies using KMRR, basic design of instrumented capsule and auxiliary system for material irradiation test and the related studies are performed. First, reactor and test hole characteristics are summarized, and conceptual design requirements of capsule to KMRR are reviewed. And fundamental principles and criteria for the instrumented capsule design are summarized. Basic design and analysis of instrumented capsule are performed, and design of capsule supporting system are also performed and structural integrity of the system is analyzed. Based on the prior studies, test mock-ups are designed and manufactured, and thermohydraulic and vibration tests are prepared. And, as in-pile test evaluation technologies, KMRR neutron dosimetry and mechanical tests related to material irradiation are investigated. 67 figs, 30 tabs, 41 refs. (Author).

  9. Main technological test loops; Les grandes boucles technologiques

    Energy Technology Data Exchange (ETDEWEB)

    Perthuis, S. de [AREVA Framatome ANP, 92 - Paris La Defense (France); Morey, J.M. [CEA Cadarache, 13 - Saint Paul lez Durance (France); Le Rouzic, J.F. [Electricite de France (EDF), 92 - Clamart (France)

    2005-07-01

    A technological test loop (TL) is a non-radioactive permanent test facility that simulates a part of power reactor. TL are built to help to design or to operate a nuclear reactor, they can be classified into 6 topics according to their purpose: 1) critical flux (allows the determination of the maximal heat flux a fuel rod can release without damage), 2) hydro-mechanics (for measuring pressure drop or flow rate distribution for instance), 3) component performance testing (for instance: valves, servomechanisms...), 4) accidental thermo-hydraulics (for the investigation of coolant loss or secondary circuit failures for instance), 5) helium technology (for investigating the behaviour of materials in presence of high temperature and high pressure helium), and 6) major reactor accidents (mainly for studying the behaviour of corium). The author reviews the technological test loops that are operated by Cea, EdF and Framatome-ANP. About 40 loops are reported. (A.C.)

  10. NDE Technology Development Program for Non-Visual Volumetric Inspection Technology; Sensor Effectiveness Testing Report

    Energy Technology Data Exchange (ETDEWEB)

    Moran, Traci L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Larche, Michael R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Denslow, Kayte M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Glass, Samuel W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-08-31

    The Pacific Northwest National Laboratory (PNNL) located in Richland, Washington, hosted and administered Sensor Effectiveness Testing that allowed four different participants to demonstrate the NDE volumetric inspection technologies that were previously demonstrated during the Technology Screening session. This document provides a Sensor Effectiveness Testing report for the final part of Phase I of a three-phase NDE Technology Development Program designed to identify and mature a system or set of non-visual volumetric NDE technologies for Hanford DST primary liner bottom inspection. Phase I of the program will baseline the performance of current or emerging non-visual volumetric NDE technologies for their ability to detect and characterize primary liner bottom flaws, and identify candidate technologies for adaptation and maturation for Phase II of the program.

  11. Is flow verification necessary

    International Nuclear Information System (INIS)

    Beetle, T.M.

    1986-01-01

    Safeguards test statistics are used in an attempt to detect diversion of special nuclear material. Under assumptions concerning possible manipulation (falsification) of safeguards accounting data, the effects on the statistics due to diversion and data manipulation are described algebraically. A comprehensive set of statistics that is capable of detecting any diversion of material is defined in terms of the algebraic properties of the effects. When the assumptions exclude collusion between persons in two material balance areas, then three sets of accounting statistics are shown to be comprehensive. Two of the sets contain widely known accountancy statistics. One of them does not require physical flow verification - comparisons of operator and inspector data for receipts and shipments. The third set contains a single statistic which does not require physical flow verification. In addition to not requiring technically difficult and expensive flow verification, this single statistic has several advantages over other comprehensive sets of statistics. This algebraic approach as an alternative to flow verification for safeguards accountancy is discussed in this paper

  12. On the safety and performance demonstration tests of Prototype Gen-IV Sodium-Cooled Fast Reactor and validation and verification of computational codes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Bum; Jeong, Ji Young; Lee, Tae Ho; Kim, Sung Kyun; Euh, Dong Jin; Joo, Hyung Kook [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    The design of Prototype Gen-IV Sodium-Cooled Fast Reactor (PGSFR) has been developed and the validation and verification (V and V) activities to demonstrate the system performance and safety are in progress. In this paper, the current status of test activities is described briefly and significant results are discussed. The large-scale sodium thermal-hydraulic test program, Sodium Test Loop for Safety Simulation and Assessment-1 (STELLA-1), produced satisfactory results, which were used for the computer codes V and V, and the performance test results of the model pump in sodium showed good agreement with those in water. The second phase of the STELLA program with the integral effect tests facility, STELLA-2, is in the detailed design stage of the design process. The sodium thermal-hydraulic experiment loop for finned-tube sodium-to-air heat exchanger performance test, the intermediate heat exchanger test facility, and the test facility for the reactor flow distribution are underway. Flow characteristics test in subchannels of a wire-wrapped rod bundle has been carried out for safety analysis in the core and the dynamic characteristic test of upper internal structure has been performed for the seismic analysis model for the PGSFR. The performance tests for control rod assemblies (CRAs) have been conducted for control rod drive mechanism driving parts and drop tests of the CRA under scram condition were performed. Finally, three types of inspection sensors under development for the safe operation of the PGSFR were explained with significant results.

  13. Power amplifier automatic test system based on LXI bus technology

    Science.gov (United States)

    Li, Yushuang; Chen, Libing; Men, Tao; Yang, Qingfeng; Li, Ning; Nie, Tao

    2017-10-01

    The power amplifier is an important part of the high power digital transceiver module, because of its great demand and diverse measurement indicators, an automatic test system is designed to meet the production requirements of the power amplifiers as the manual test cannot meet the demand of consistency. This paper puts forward the plan of the automatic test system based on LXI bus technology, introduces the hardware and software architecture of the system. The test system has been used for debugging and testing the power amplifiers stably and efficiently, which greatly saves work force and effectively improves productivity.

  14. Testing a Regenerative Carbon Dioxide and Moisture Removal Technology

    Science.gov (United States)

    Barta, Daniel J.; Button, Amy; Sweterlitsch, Jeffrey J.; Curley, Suzanne

    2010-01-01

    The National Aeronautics and Space Administration supported the development of a new vacuum-desorbed regenerative carbon dioxide and humidity control technology for use in short duration human spacecraft. The technology was baselined for use in the Orion Crew Exploration Vehicle s Environmental Control and Life Support System (ECLSS). Termed the Carbon Dioxide And Moisture Removal Amine Swing-bed (CAMRAS), the unit was developed by Hamilton Sundstrand and has undergone extensive testing at Johnson Space Center. The tests were performed to evaluate performance characteristics under range of operating conditions and human loads expected in future spacecraft applications, as part of maturation to increase its readiness for flight. Early tests, conducted at nominal atmospheric pressure, used human metabolic simulators to generate loads, with later tests making us of human test subjects. During these tests many different test cases were performed, involving from 1 to 6 test subjects, with different activity profiles (sleep, nominal and exercise). These tests were conducted within the airlock portion of a human rated test chamber sized to simulate the Orion cabin free air volume. More recently, a test was completed that integrated the CAMRAS with a simulated suit loop using prototype umbilicals and was conducted at reduced atmospheric pressure and elevated oxygen levels. This paper will describe the facilities and procedures used to conduct these and future tests, and provide a summary of findings.

  15. Hybrid microcircuit technology handbook materials, processes, design, testing and production

    CERN Document Server

    Licari, James J

    1998-01-01

    The Hybrid Microcircuit Technology Handbook integrates the many diverse technologies used in the design, fabrication, assembly, and testing of hybrid segments crucial to the success of producing reliable circuits in high yields. Among these are: resistor trimming, wire bonding, die attachment, cleaning, hermetic sealing, and moisture analysis. In addition to thin films, thick films, and assembly processes, important chapters on substrate selections, handling (including electrostatic discharge), failure analysis, and documentation are included. A comprehensive chapter of design guidelines will

  16. Testing of Materials for Rapid Prototyping Fused Deposition Modelling Technology

    OpenAIRE

    L. Novakova-Marcincinova; J. Novak-Marcincin

    2012-01-01

    Paper presents knowledge about types of test in area of materials properties of selected methods of rapid prototyping technologies. In today used rapid prototyping technologies for production of models and final parts are used materials in initial state as solid, liquid or powder material structure. In solid state are used various forms such as pellets, wire or laminates. Basic range materials include paper, nylon, wax, resins, metals and ceramics. In Fused Deposition Mod...

  17. A Formal Approach to the Verification of Networks on Chip

    Directory of Open Access Journals (Sweden)

    Schmaltz Julien

    2009-01-01

    Full Text Available Abstract The current technology allows the integration on a single die of complex systems-on-chip (SoCs that are composed of manufactured blocks (IPs, interconnected through specialized networks on chip (NoCs. IPs have usually been validated by diverse techniques (simulation, test, formal verification and the key problem remains the validation of the communication infrastructure. This paper addresses the formal verification of NoCs by means of a mechanized proof tool, the ACL2 theorem prover. A metamodel for NoCs has been developed and implemented in ACL2. This metamodel satisfies a generic correctness statement. Its verification for a particular NoC instance is reduced to discharging a set of proof obligations for each one of the NoC constituents. The methodology is demonstrated on a realistic and state-of-the-art design, the Spidergon network from STMicroelectronics.

  18. Development of modelling algorithm of technological systems by statistical tests

    Science.gov (United States)

    Shemshura, E. A.; Otrokov, A. V.; Chernyh, V. G.

    2018-03-01

    The paper tackles the problem of economic assessment of design efficiency regarding various technological systems at the stage of their operation. The modelling algorithm of a technological system was performed using statistical tests and with account of the reliability index allows estimating the level of machinery technical excellence and defining the efficiency of design reliability against its performance. Economic feasibility of its application shall be determined on the basis of service quality of a technological system with further forecasting of volumes and the range of spare parts supply.

  19. Honeycomb technology materials, design, manufacturing, applications and testing

    CERN Document Server

    Bitzer, Tom

    1997-01-01

    Honeycomb Technology is a guide to honeycomb cores and honeycomb sandwich panels, from the manufacturing methods by which they are produced, to the different types of design, applications for usage and methods of testing the materials. It explains the different types of honeycomb cores available and provides tabulated data of their properties. The author has been involved in the testing and design of honeycomb cores and sandwich panels for nearly 30 years. Honeycomb Technology reflects this by emphasizing a `hands-on' approach and discusses procedures for designing sandwich panels, explaining the necessary equations. Also included is a section on how to design honeycomb energy absorbers and one full chapter discussing honeycomb core and sandwich panel testing. Honeycomb Technology will be of interest to engineers in the aircraft, aerospace and building industries. It will also be of great use to engineering students interested in basic sandwich panel design.

  20. Partial Defect Verification of Spent Fuel Assemblies by PDET: Principle and Field Testing in Interim Spent Fuel Storage Facility (CLAB) in Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Ham, Y.S.; Kerr, P.; Sitaraman, S.; Swan, R. [Global Security Directorate, Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Rossa, R. [SCK-CEN, Mol (Belgium); Liljenfeldt, H. [SKB in Oskarshamn (Sweden)

    2015-07-01

    The need for the development of a credible method and instrument for partial defect verification of spent fuel has been emphasized over a few decades in the safeguards communities as the diverted spent fuel pins can be the source of nuclear terrorism or devices. The need is increasingly more important and even urgent as many countries have started to transfer spent fuel to so called 'difficult-to-access' areas such as dry storage casks, reprocessing or geological repositories. Partial defect verification is required by IAEA before spent fuel is placed into 'difficult-to-access' areas. Earlier, Lawrence Livermore National Laboratory (LLNL) has reported the successful development of a new, credible partial defect verification method for pressurized water reactor (PWR) spent fuel assemblies without use of operator data, and further reported the validation experiments using commercial spent fuel assemblies with some missing fuel pins. The method was found to be robust as the method is relatively invariant to the characteristic variations of spent fuel assemblies such as initial fuel enrichment, cooling time, and burn-up. Since then, the PDET system has been designed and prototyped for 17x17 PWR spent fuel assemblies, complete with data acquisition software and acquisition electronics. In this paper, a summary description of the PDET development followed by results of the first successful field testing using the integrated PDET system and actual spent fuel assemblies performed in a commercial spent fuel storage site, known as Central Interim Spent fuel Storage Facility (CLAB) in Sweden will be presented. In addition to partial defect detection initial studies have determined that the tool can be used to verify the operator declared average burnup of the assembly as well as intra-assembly burnup levels. (authors)

  1. NASA funding opportunities for optical fabrication and testing technology development

    Science.gov (United States)

    Stahl, H. Philip

    2013-09-01

    NASA requires technologies to fabricate and test optical components to accomplish its highest priority science missions. The NRC ASTRO2010 Decadal Survey states that an advanced large-aperture UVOIR telescope is required to enable the next generation of compelling astrophysics and exo-planet science; and, that present technology is not mature enough to affordably build and launch any potential UVOIR mission concept. The NRC 2012 NASA Space Technology Roadmaps and Priorities Report states that the highest priority technology in which NASA should invest to `Expand our understanding of Earth and the universe' is next generation X-ray and UVOIR telescopes. Each of the Astrophysics division Program Office Annual Technology Reports (PATR) identifies specific technology needs. NASA has a variety of programs to fund enabling technology development: SBIR (Small Business Innovative Research); the ROSES APRA and SAT programs (Research Opportunities in Space and Earth Science; Astrophysics Research and Analysis program; Strategic Astrophysics Technology program); and several Office of the Chief Technologist (OCT) programs.

  2. New technologies in electromagnetic non-destructive testing

    CERN Document Server

    Huang, Songling

    2016-01-01

    This book introduces novel developments in the field of electromagnetic non-destructive testing and evaluation (NDT/E). The topics include electromagnetic ultrasonic guided wave testing, pulsed eddy current testing, remote field eddy current testing, low frequency eddy current testing, metal magnetic memory testing, and magnetic flux leakage testing. Considering the increasing concern about the safety maintenance of critical structures in various industries and everyday life, these topics presented here will be of particular interest to the readers in the NDT/E field. This book covers both theoretical researches and the engineering applications of the electromagnetic NDT technology. It could serve as a valuable reference for college students and relevant NDT technicians. It is also a useful material for qualification training and higher learning for nondestructive testing professionals.

  3. Space Suit Environment Testing of the Orion Atmosphere Revitalization Technology

    Science.gov (United States)

    Button, Amy B.; Sweterlitsch, Jeffrey J.; Cox, Marlon R.

    2010-01-01

    An amine-based carbon dioxide (CO2) and water vapor sorbent in pressure-swing regenerable beds has been developed by Hamilton Sundstrand and baselined for the Orion Atmosphere Revitalization System (ARS). In three previous years at this conference, reports were presented on extensive Johnson Space Center (JSC) testing of this technology. That testing was performed in a sea-level pressure environment with both simulated and real human metabolic loads, and in both open and closed-loop configurations. The Orion ARS is designed to also support space-suited operations in a depressurized cabin, so the next step in developmental testing at JSC was to test the ARS technology in a typical closed space suit-loop environment with low-pressure oxygen inside the process loop and vacuum outside the loop. This was the first instance of low-pressure, high-oxygen, closed-loop testing of the Orion ARS technology, and it was conducted with simulated human metabolic loads in March 2009. The test investigated pressure drops and flow balancing through two different styles of prototype suit umbilical connectors. General swing-bed performance was tested with both umbilical configurations, as well as with a short jumper line installed in place of the umbilicals. Other interesting results include observations on the thermal effects of swing-bed operation in a vacuum environment and a recommendation of cycle time to maintain acceptable suit atmospheric CO2 and moisture levels.

  4. An assessment of nondestructive testing technologies for chemical weapons monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, T.T.

    1993-05-01

    The US Department of Energy (DOE), with the US Army Chemical Research, Development and Engineering Center (CRDEC) under the sponsorship of the Defense Nuclear Agency (DNA), completed testing of Nondestructive Evaluation (NDE) technology on live agent systems. The tests were conducted at Tooele Army Depot during August 1992. The Nondestructive Evaluation systems were tested for potential use in verifying chemical treaty requirements. Five technologies, two neutron and three acoustic, were developed at DOE laboratories. Two systems from the United Kingdom (one neutron and one acoustic) were also included in the field trials. All systems tested showed the ability to distinguish among the VX, GB, and Mustard. Three of the systems (two acoustic and one neutron) were used by On-Site Inspection Agency (OSIA) personnel.

  5. Selected Test Results from the Encell Technology Nickel Iron Battery

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Summer Kamal Rhodes [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Power Sources R& D; Baca, Wes Edmund [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Power Sources R& D; Avedikian, Kristan [Encell Technology, Alachua, FL (United States)

    2014-09-01

    The performance of the Encell Nickel Iron (NiFe) battery was measured. Tests included capacity, capacity as a function of rate, capacity as a function of temperature, charge retention (28-day), efficiency, accelerated life projection, and water refill evaluation. The goal of this work was to evaluate the general performance of the Encell NiFe battery technology for stationary applications and demonstrate the chemistry's capabilities in extreme conditions. Test results have indicated that the Encell NiFe battery technology can provide power levels up to the 6C discharge rate, ampere-hour efficiency above 70%. In summary, the Encell batteries have met performance metrics established by the manufacturer. Long-term cycle tests are not included in this report. A cycle test at elevated temperature was run, funded by the manufacturer, which Encell uses to predict long-term cycling performance, and which passed their prescribed metrics.

  6. Description of a Computer Program Written for Approach and Landing Test Post Flight Data Extraction of Proximity Separation Aerodynamic Coefficients and Aerodynamic Data Base Verification

    Science.gov (United States)

    Homan, D. J.

    1977-01-01

    A computer program written to calculate the proximity aerodynamic force and moment coefficients of the Orbiter/Shuttle Carrier Aircraft (SCA) vehicles based on flight instrumentation is described. The ground reduced aerodynamic coefficients and instrumentation errors (GRACIE) program was developed as a tool to aid in flight test verification of the Orbiter/SCA separation aerodynamic data base. The program calculates the force and moment coefficients of each vehicle in proximity to the other, using the load measurement system data, flight instrumentation data and the vehicle mass properties. The uncertainty in each coefficient is determined, based on the quoted instrumentation accuracies. A subroutine manipulates the Orbiter/747 Carrier Separation Aerodynamic Data Book to calculate a comparable set of predicted coefficients for comparison to the calculated flight test data.

  7. RF and microwave integrated circuit development technology, packaging and testing

    CERN Document Server

    Gamand, Patrice; Kelma, Christophe

    2018-01-01

    RF and Microwave Integrated Circuit Development bridges the gap between existing literature, which focus mainly on the 'front-end' part of a product development (system, architecture, design techniques), by providing the reader with an insight into the 'back-end' part of product development. In addition, the authors provide practical answers and solutions regarding the choice of technology, the packaging solutions and the effects on the performance on the circuit and to the industrial testing strategy. It will also discuss future trends and challenges and includes case studies to illustrate examples. * Offers an overview of the challenges in RF/microwave product design * Provides practical answers to packaging issues and evaluates its effect on the performance of the circuit * Includes industrial testing strategies * Examines relevant RF MIC technologies and the factors which affect the choice of technology for a particular application, e.g. technical performance and cost * Discusses future trends and challen...

  8. Utility advanced turbine systems (ATS) technology readiness testing

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-09-15

    The overall objective of the Advanced Turbine System (ATS) Phase 3 Cooperative Agreement between GE and the US Department of Energy (DOE) is the development of a highly efficient, environmentally superior, and cost-competitive utility ATS for base-load utility-scale power generation, the GE 7H (60 Hz) combined cycle power system, and related 9H (50 Hz) common technology. The major effort will be expended on detail design. Validation of critical components and technologies will be performed, including: hot gas path component testing, sub-scale compressor testing, steam purity test trials, and rotational heat transfer confirmation testing. Processes will be developed to support the manufacture of the first system, which was to have been sited and operated in Phase 4 but will now be sited and operated commercially by GE. This change has resulted from DOE's request to GE for deletion of Phase 4 in favor of a restructured Phase 3 (as Phase 3R) to include full speed, no load (FSNL) testing of the 7H gas turbine. Technology enhancements that are not required for the first machine design but will be critical for future ATS advances in performance, reliability, and costs will be initiated. Long-term tests of materials to confirm design life predictions will continue. A schematic of the GE H machine is shown.

  9. Methods of Software Verification

    Directory of Open Access Journals (Sweden)

    R. E. Gurin

    2015-01-01

    Full Text Available This article is devoted to the problem of software verification (SW. Methods of software verification designed to check the software for compliance with the stated requirements such as correctness, system security and system adaptability to small changes in the environment, portability and compatibility, etc. These are various methods both by the operation process and by the way of achieving result. The article describes the static and dynamic methods of software verification and paid attention to the method of symbolic execution. In its review of static analysis are discussed and described the deductive method, and methods for testing the model. A relevant issue of the pros and cons of a particular method is emphasized. The article considers classification of test techniques for each method. In this paper we present and analyze the characteristics and mechanisms of the static analysis of dependencies, as well as their views, which can reduce the number of false positives in situations where the current state of the program combines two or more states obtained both in different paths of execution and in working with multiple object values. Dependences connect various types of software objects: single variables, the elements of composite variables (structure fields, array elements, the size of the heap areas, the length of lines, the number of initialized array elements in the verification code using static methods. The article pays attention to the identification of dependencies within the framework of the abstract interpretation, as well as gives an overview and analysis of the inference tools.Methods of dynamic analysis such as testing, monitoring and profiling are presented and analyzed. Also some kinds of tools are considered which can be applied to the software when using the methods of dynamic analysis. Based on the work a conclusion is drawn, which describes the most relevant problems of analysis techniques, methods of their solutions and

  10. Replacement of Hydrochlorofluorocarbon (HCFC) -225 Solvent for Cleaning and Verification Sampling of NASA Propulsion Oxygen Systems Hardware, Ground Support Equipment, and Associated Test Systems

    Science.gov (United States)

    Mitchell, Mark A.; Lowrey, Nikki M.

    2015-01-01

    Since the 1990's, when the Class I Ozone Depleting Substance (ODS) chlorofluorocarbon-113 (CFC-113) was banned, NASA's rocket propulsion test facilities at Marshall Space Flight Center (MSFC) and Stennis Space Center (SSC) have relied upon hydrochlorofluorocarbon-225 (HCFC-225) to safely clean and verify the cleanliness of large scale propulsion oxygen systems. Effective January 1, 2015, the production, import, export, and new use of HCFC-225, a Class II ODS, was prohibited by the Clean Air Act. In 2012 through 2014, leveraging resources from both the NASA Rocket Propulsion Test Program and the Defense Logistics Agency - Aviation Hazardous Minimization and Green Products Branch, test labs at MSFC, SSC, and Johnson Space Center's White Sands Test Facility (WSTF) collaborated to seek out, test, and qualify a replacement for HCFC-225 that is both an effective cleaner and safe for use with oxygen systems. Candidate solvents were selected and a test plan was developed following the guidelines of ASTM G127, Standard Guide for the Selection of Cleaning Agents for Oxygen Systems. Solvents were evaluated for materials compatibility, oxygen compatibility, cleaning effectiveness, and suitability for use in cleanliness verification and field cleaning operations. Two solvents were determined to be acceptable for cleaning oxygen systems and one was chosen for implementation at NASA's rocket propulsion test facilities. The test program and results are summarized. This project also demonstrated the benefits of cross-agency collaboration in a time of limited resources.

  11. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Performance Verification Reports: Final Comprehensive Performance Test Report, P/N: 1356006-1, S.N: 202/A2

    Science.gov (United States)

    Platt, R.

    1998-01-01

    This is the Performance Verification Report. the process specification establishes the requirements for the comprehensive performance test (CPT) and limited performance test (LPT) of the earth observing system advanced microwave sounding unit-A2 (EOS/AMSU-A2), referred to as the unit. The unit is defined on drawing 1356006.

  12. 2009 Continued Testing of the Orion Atmosphere Revitalization Technology

    Science.gov (United States)

    Button, Amy B.; Swerterlitsch, Jeffrey J.

    2010-01-01

    An amine-based carbon dioxide (CO2) and water vapor sorbent in pressure-swing regenerable beds has been developed by Hamilton Sundstrand and baselined for the Orion Atmosphere Revitalization System (ARS). In three previous years at this conference, reports were presented on extensive Johnson Space Center (JSC) testing of this technology in a sea-level pressure environment, with simulated and real human metabolic loads, in both open and closed-loop configurations. The test article design was iterated a third time before the latest series of such tests, which was performed in the first half of 2009. The new design incorporates a canister configuration modification for overall unit compactness and reduced pressure drop, as well as a new process flow control valve that incorporates both compressed gas purge and dual-end vacuum desorption capabilities. This newest test article is very similar to the flight article designs. Baseline tests of the new unit were performed to compare its performance to that of the previous test articles. Testing of compressed gas purge operations helped refine launchpad operating condition recommendations developed in earlier testing. Operating conditions used in flight program computer models were tested to validate the model projections. Specific operating conditions that were recommended by the JSC test team based on past test results were also tested for validation. The effects of vacuum regeneration line pressure on resulting cabin conditions was studied for high metabolic load periods, and a maximum pressure is recommended

  13. Heavy Section Steel Technology Program. Part II. Intermediate vessel testing

    International Nuclear Information System (INIS)

    Whitman, G.D.

    1975-01-01

    The testing of the intermediate pressure vessels is a major activity under the Heavy Section Steel Technology Program. A primary objective of these tests is to develop or verify methods of fracture prediction, through the testing of selected structures and materials, in order that a valid basis can be established for evaluating the serviceability and safety of light-water reactor pressure vessels. These vessel tests were planned with sufficiently specific objectives that substantial quantitative weight could be given to the results. Each set of testing conditions was chosen so as to provide specific data by which analytical methods of predicting flaw growth, and in some cases crack arrest, could be evaluated. Every practical effort was made to assure that results would be relevant to some aspect of real reactor pressure vessel performance through careful control of material properties, selection of test temperatures, and design of prepared flaws. 5 references

  14. A Study on Test Technology to Diagnose the Power Apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Kim, K. H.; Kang, Y. S.; Jeon, Y. K.; Lee, W. Y.; Kang, D. S.; Kyu, H. S.; Sun, J. H.; Jo, K. H. [Korea Electrotechnology Research Institute (Korea, Republic of); Jung, J. S.; Mun, Y. T.; Lee, K. H.; Jung, E. H.; Kim, J. H. [Korea Water Resources Corporation (Korea, Republic of)

    1997-02-01

    In this study, we have educated KOWACO(Korea Water Resources Corporation) specialists about the insulation diagnostic technology and trained them the insulation diagnostic test and estimation method of power apparatus. The main results of this study are as follows; A. Education of basic high-voltage engineering. B. Research of insulation characteristic and deterioration mechanism in power apparatus C. Discussion on high-voltage test standard specifications. D. Study on insulation deterioration diagnostics in power apparatus. E. Field testing of insulation diagnosis in power apparatus. F. Engineering of insulation diagnostic testing apparatus to diagnose power apparatus. KOWACO specialists are able to diagnose insulation diagnostic test of power apparatus through this study. As they have instruments to diagnose power apparatus, they can do the test and estimation of the power apparatus insulation diagnosis. (author). refs., figs., tabs.

  15. Trace Contaminant Testing with the Orion Atmosphere Revitalization Technology

    Science.gov (United States)

    Button, Amy B.; Sweterlitsch, Jeffrey J.; Broerman, Craig D.; Campbell, Melissa L.

    2010-01-01

    Every spacecraft atmosphere contains trace contaminants resulting from offgassing by cabin materials and human passengers. An amine-based carbon dioxide (CO2) and water vapor sorbent in pressure-swing regenerable beds has been developed by Hamilton Sundstrand and baselined for the Orion Atmosphere Revitalization System (ARS). Part of the risk mitigation effort for this new technology is the study of how atmospheric trace contaminants will affect and be affected by the technology. One particular area of concern is ammonia, which, in addition to the normal spacecraft sources, can also be offgassed by the amine-based sorbent. In the spring of 2009, tests were performed at Johnson Space Center (JSC) with typical cabin atmosphere levels of five of the most common trace gases, most of which had not yet been tested with this technology. A subscale sample of the sorbent was exposed to each of the chemicals mixed into a stream of moist, CO2-laden air, and the CO2 adsorption capacity of the sorbent was compared before and after the exposure. After these typical-concentration chemicals were proven to have negligible effect on the subscale sample, tests proceeded on a full-scale test article in a sealed chamber with a suite of eleven contaminants. To isolate the effects of various test rig components, several extended-duration tests were run: without injection or scrubbing, with injection and without scrubbing, with injection of both contaminants and metabolic CO2 and water vapor loads and scrubbing by both the test article and dedicated trace contaminant filters, and with the same injections and scrubbing by only the test article. The high-level results of both the subscale and full-scale tests are examined in this paper.

  16. Swarm Verification

    Science.gov (United States)

    Holzmann, Gerard J.; Joshi, Rajeev; Groce, Alex

    2008-01-01

    Reportedly, supercomputer designer Seymour Cray once said that he would sooner use two strong oxen to plow a field than a thousand chickens. Although this is undoubtedly wise when it comes to plowing a field, it is not so clear for other types of tasks. Model checking problems are of the proverbial "search the needle in a haystack" type. Such problems can often be parallelized easily. Alas, none of the usual divide and conquer methods can be used to parallelize the working of a model checker. Given that it has become easier than ever to gain access to large numbers of computers to perform even routine tasks it is becoming more and more attractive to find alternate ways to use these resources to speed up model checking tasks. This paper describes one such method, called swarm verification.

  17. The development of verification and validation technology for instrumentation and control in NPPs - A study on the software development methodology of a highly reliable software

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Yong Rae; Cha, Sung Deok; Lee, Woo Jin; Chae, Hong Seok; Yoon, Kwang Sik; Jeong, Ki Suk [Korea Advanced Institute of Science and Technology,= Taejon (Korea, Republic of)

    1996-07-01

    Nuclear industries have tried to use the digital I and C technology in developing advanced nuclear power plants. However, because the industries did= not establish the highly reliable software development methodologies and standards applied to developing the highly reliable and safe software for digital I and C systems, they were confronted with the difficulties to avoid software common mode failures. To mitigate the difficulties, the highly reliable software development environments and methodologies and validation and verification techniques should be the cornerstone of all digital implementation in nuclear power plants. The objectives of this project is to establish the highly reliable software development methodology to support developing digital instrumentation and control systems in nuclear power plants. In this project, we have investigated the business-oriented and the real-time software development methods and techniques for ensuring safety and reliability of the software. Also we have studied standards related to licensing the software for digital I and C systems. 50 refs., 51 figs. (author)

  18. RESRAD-BUILD verification

    International Nuclear Information System (INIS)

    Kamboj, S.; Yu, C.; Biwer, B. M.; Klett, T.

    2002-01-01

    The results generated by the RESRAD-BUILD code (version 3.0) were verified with hand or spreadsheet calculations using equations given in the RESRAD-BUILD manual for different pathways. For verification purposes, different radionuclides--H-3, C-14, Na-22, Al-26, Cl-36, Mn-54, Co-60, Au-195, Ra-226, Ra-228, Th-228, and U-238--were chosen to test all pathways and models. Tritium, Ra-226, and Th-228 were chosen because of the special tritium and radon models in the RESRAD-BUILD code. Other radionuclides were selected to represent a spectrum of radiation types and energies. Verification of the RESRAD-BUILD code was conducted with an initial check of all the input parameters for correctness against their original source documents. Verification of the calculations was performed external to the RESRAD-BUILD code with Microsoft Excel to verify all the major portions of the code. In some cases, RESRAD-BUILD results were compared with those of external codes, such as MCNP (Monte Carlo N-particle) and RESRAD. The verification was conducted on a step-by-step basis and used different test cases as templates. The following types of calculations were investigated: (1) source injection rate, (2) air concentration in the room, (3) air particulate deposition, (4) radon pathway model, (5) tritium model for volume source, (6) external exposure model, (7) different pathway doses, and (8) time dependence of dose. Some minor errors were identified in version 3.0; these errors have been corrected in later versions of the code. Some possible improvements in the code were also identified

  19. First Human Testing of the Orion Atmosphere Revitalization Technology

    Science.gov (United States)

    Lin, Amy; Sweterlitsch, Jeffrey

    2009-01-01

    An amine-based carbon dioxide (CO2) and water vapor sorbent in pressure-swing regenerable beds has been developed by Hamilton Sundstrand and baselined for the Orion Atmosphere Revitalization System (ARS). In two previous years at this conference, reports were presented on extensive Johnson Space Center (JSC) testing of the technology in a representative environment with simulated human metabolic loads. The next step in developmental testing at JSC was to replace the simulated humans with real humans; this testing was conducted in the spring of 2008. This first instance of human testing of a new Orion ARS technology included several cases in a sealed Orion-equivalent free volume and three cases using emergency breathing masks connected directly to the ARS loop. Significant test results presented in this paper include comparisons between the standard metabolic rates for CO2 and water vapor production published in Orion requirements documents and real-world rate ranges observed with human test subjects. Also included are qualitative assessments of process flow rate and closed-loop pressure-cycling tolerability while using the emergency masks. Recommendations for modifications to the Orion ARS design and operation, based on the test results, conclude the paper.

  20. Tube and column agglutination technology for autocontrol testing.

    Science.gov (United States)

    Courtney, J E; Vincent, J L; Indrikovs, A J

    2001-01-01

    The incidence of positive autocontrol test results with column agglutination technology is a concern. This study investigates the incidence and significance of positive autocontrols in the ID Micro Typing System (gel) and the Gamma ReACT (ReACT). The study encompassed a total of 1021 randomly selected samples from patients and 95 samples from donors collected during 1 month. The autocontrol testing was carried out according to the manufacturer's instructions for the column agglutination tests. The tube method was carried out using low-ionic-strength solution (LISS). The direct antiglobulin test (DAT) was performed using the tube method, and further investigated with elution studies if warranted. Seventy-nine patient's samples (7.74%) had a positive autocontrol: the gel test, 72 (91.13%); ReACT, 21 (26.58%); and the tube method, 27 (34.18%). Of the 79 positive autocontrols, 44 samples had a negative DAT. Of the samples with positive DAT results, only one possessed a clinically significant antibody, anti-D. Moreover, the same sample also tested positive in all three methods. Column agglutination techniques have increased sensitivity for a positive autocontrol beyond the conventional tube method. However, ReACT and gel tests differ significantly in their frequency of positives. Investigation of the significance of a positive autocontrol in column agglutination technology when the conventional tube method is also positive is suggested.

  1. Nuclear waste repository transparency technology test bed demonstrations at WIPP

    International Nuclear Information System (INIS)

    Betsill J, David; Elkins, Ned Z.; Wu, Chuan-Fu; Mewhinney, James D.; Aamodt, Paul

    2000-01-01

    Secretary of Energy, Bill Richardson, has stated that one of the nuclear waste legacy issues is ''The challenge of managing the fuel cycle's back end and assuring the safe use of nuclear power.'' Waste management (i.e., the back end) is a domestic and international issue that must be addressed. A key tool in gaining acceptance of nuclear waste repository technologies is transparency. Transparency provides information to outside parties for independent assessment of safety, security, and legitimate use of materials. Transparency is a combination of technologies and processes that apply to all elements of the development, operation, and closure of a repository system. A test bed for nuclear repository transparency technologies has been proposed to develop a broad-based set of concepts and strategies for transparency monitoring of nuclear materials at the back end of the fuel/weapons cycle. WIPP is the world's first complete geologic repository system for nuclear materials at the back end of the cycle. While it is understood that WIPP does not currently require this type of transparency, this repository has been proposed as realistic demonstration site to generate and test ideas, methods, and technologies about what transparency may entail at the back end of the nuclear materials cycle, and which could be applicable to other international repository developments. An integrated set of transparency demonstrations was developed and deployed during the summer, and fall of 1999 as a proof-of-concept of the repository transparency technology concept. These demonstrations also provided valuable experience and insight into the implementation of future transparency technology development and application. These demonstrations included: Container Monitoring Rocky Flats to WIPP; Underground Container Monitoring; Real-Time Radiation and Environmental Monitoring; Integrated level of confidence in the system and information provided. As the world's only operating deep geologic

  2. Nuclear waste repository transparency technology test bed demonstrations at WIPP

    Energy Technology Data Exchange (ETDEWEB)

    BETSILL,J. DAVID; ELKINS,NED Z.; WU,CHUAN-FU; MEWHINNEY,JAMES D.; AAMODT,PAUL

    2000-01-27

    Secretary of Energy, Bill Richardson, has stated that one of the nuclear waste legacy issues is ``The challenge of managing the fuel cycle's back end and assuring the safe use of nuclear power.'' Waste management (i.e., the back end) is a domestic and international issue that must be addressed. A key tool in gaining acceptance of nuclear waste repository technologies is transparency. Transparency provides information to outside parties for independent assessment of safety, security, and legitimate use of materials. Transparency is a combination of technologies and processes that apply to all elements of the development, operation, and closure of a repository system. A test bed for nuclear repository transparency technologies has been proposed to develop a broad-based set of concepts and strategies for transparency monitoring of nuclear materials at the back end of the fuel/weapons cycle. WIPP is the world's first complete geologic repository system for nuclear materials at the back end of the cycle. While it is understood that WIPP does not currently require this type of transparency, this repository has been proposed as realistic demonstration site to generate and test ideas, methods, and technologies about what transparency may entail at the back end of the nuclear materials cycle, and which could be applicable to other international repository developments. An integrated set of transparency demonstrations was developed and deployed during the summer, and fall of 1999 as a proof-of-concept of the repository transparency technology concept. These demonstrations also provided valuable experience and insight into the implementation of future transparency technology development and application. These demonstrations included: Container Monitoring Rocky Flats to WIPP; Underground Container Monitoring; Real-Time Radiation and Environmental Monitoring; Integrated level of confidence in the system and information provided. As the world's only

  3. On the Safety and Performance Demonstration Tests of Prototype Gen-IV Sodium-Cooled Fast Reactor and Validation and Verification of Computational Codes

    Directory of Open Access Journals (Sweden)

    Jong-Bum Kim

    2016-10-01

    Full Text Available The design of Prototype Gen-IV Sodium-Cooled Fast Reactor (PGSFR has been developed and the validation and verification (V&V activities to demonstrate the system performance and safety are in progress. In this paper, the current status of test activities is described briefly and significant results are discussed. The large-scale sodium thermal-hydraulic test program, Sodium Test Loop for Safety Simulation and Assessment-1 (STELLA-1, produced satisfactory results, which were used for the computer codes V&V, and the performance test results of the model pump in sodium showed good agreement with those in water. The second phase of the STELLA program with the integral effect tests facility, STELLA-2, is in the detailed design stage of the design process. The sodium thermal-hydraulic experiment loop for finned-tube sodium-to-air heat exchanger performance test, the intermediate heat exchanger test facility, and the test facility for the reactor flow distribution are underway. Flow characteristics test in subchannels of a wire-wrapped rod bundle has been carried out for safety analysis in the core and the dynamic characteristic test of upper internal structure has been performed for the seismic analysis model for the PGSFR. The performance tests for control rod assemblies (CRAs have been conducted for control rod drive mechanism driving parts and drop tests of the CRA under scram condition were performed. Finally, three types of inspection sensors under development for the safe operation of the PGSFR were explained with significant results.

  4. Verification of in-core thermal and hydraulic analysis code FLOWNET/TRUMP for the high temperature engineering test reactor (HTTR) at JAERI

    International Nuclear Information System (INIS)

    Maruyama, Soh; Sudo, Yukio; Saito, Shinzo; Kiso, Yoshihiro; Hayakawa, Hitoshi

    1989-01-01

    The FLOWNET/TRUMP code consists of a flow network analysis code 'FLOWNET' for calculations of coolant flow distribution and coolant temperature distribution in the core with a thermal conduction analysis code 'TRUMP' for calculation of temperature distribution in solid structures. The verification of FLOWNET/TRUMP was made by the comparison of the analytical results with the results of steady state experiments by the HENDEL multichannel test rig, T1-M, which consisted of twelve simulated fuel rods heated electrically and eleven hexagonal graphite fuel blocks. The T1-M simulated the one fuel column in the core. The analytical results agreed well with the results of the experiment in which the HTTR operating conditions were simulated. (orig.)

  5. Proceedings of the Joint IAEA/CSNI Specialists` Meeting on Fracture Mechanics Verification by Large-Scale Testing held at Pollard Auditorium, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    Pugh, C.E.; Bass, B.R.; Keeney, J.A. [comps.] [Oak Ridge National Lab., TN (United States)

    1993-10-01

    This report contains 40 papers that were presented at the Joint IAEA/CSNI Specialists` Meeting Fracture Mechanics Verification by Large-Scale Testing held at the Pollard Auditorium, Oak Ridge, Tennessee, during the week of October 26--29, 1992. The papers are printed in the order of their presentation in each session and describe recent large-scale fracture (brittle and/or ductile) experiments, analyses of these experiments, and comparisons between predictions and experimental results. The goal of the meeting was to allow international experts to examine the fracture behavior of various materials and structures under conditions relevant to nuclear reactor components and operating environments. The emphasis was on the ability of various fracture models and analysis methods to predict the wide range of experimental data now available. The individual papers have been cataloged separately.

  6. Utility Advanced Turbine Systems (ATS) technology readiness testing

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-05-01

    The overall objective of the Advanced Turbine System (ATS) Phase 3 Cooperative Agreement between GE and the US Department of Energy (DOE) is the development of the GE 7H and 9H combined cycle power systems. The major effort will be expended on detail design. Validation of critical components and technologies will be performed, including: hot gas path component testing, sub-scale compressor testing, steam purity test trials, and rotational heat transfer confirmation testing. Processes will be developed to support the manufacture of the first system, which was to have been sited and operated in Phase 4 but will now be sited and operated commercially by GE. This change has resulted horn DOE's request to GE for deletion of Phase 4 in favor of a restructured Phase 3 (as Phase 3R) to include fill speed, no load (FSNL) testing of the 7H gas turbine. Technology enhancements that are not required for the first machine design but will be critical for future ATS advances in performance, reliability, and costs will be initiated. Long-term tests of materials to confirm design life predictions will continue. A schematic of the GE H machine is shown.

  7. Skin Testing for Allergic Rhinitis: A Health Technology Assessment.

    Science.gov (United States)

    2016-01-01

    Allergic rhinitis is the most common type of allergy worldwide. The accuracy of skin testing for allergic rhinitis is still debated. This health technology assessment had two objectives: to determine the diagnostic accuracy of skin-prick and intradermal testing in patients with suspected allergic rhinitis and to estimate the costs to the Ontario health system of skin testing for allergic rhinitis. We searched All Ovid MEDLINE, Embase, and Cochrane Database of Systematic Reviews, Database of Abstracts of Reviews of Effects, CRD Health Technology Assessment Database, Cochrane Central Register of Controlled Trials, and NHS Economic Evaluation Database for studies that evaluated the diagnostic accuracy of skin-prick and intradermal testing for allergic rhinitis using nasal provocation as the reference standard. For the clinical evidence review, data extraction and quality assessment were performed using the QUADAS-2 tool. We used the bivariate random-effects model for meta-analysis. For the economic evidence review, we assessed studies using a modified checklist developed by the (United Kingdom) National Institute for Health and Care Excellence. We estimated the annual cost of skin testing for allergic rhinitis in Ontario for 2015 to 2017 using provincial data on testing volumes and costs. We meta-analyzed seven studies with a total of 430 patients that assessed the accuracy of skin-prick testing. The pooled pair of sensitivity and specificity for skin-prick testing was 85% and 77%, respectively. We did not perform a meta-analysis for the diagnostic accuracy of intradermal testing due to the small number of studies (n = 4). Of these, two evaluated the accuracy of intradermal testing in confirming negative skin-prick testing results, with sensitivity ranging from 27% to 50% and specificity ranging from 60% to 100%. The other two studies evaluated the accuracy of intradermal testing as a stand-alone tool for diagnosing allergic rhinitis, with sensitivity ranging from 60

  8. Skin Testing for Allergic Rhinitis: A Health Technology Assessment

    Science.gov (United States)

    Kabali, Conrad; Chan, Brian; Higgins, Caroline; Holubowich, Corinne

    2016-01-01

    Background Allergic rhinitis is the most common type of allergy worldwide. The accuracy of skin testing for allergic rhinitis is still debated. This health technology assessment had two objectives: to determine the diagnostic accuracy of skin-prick and intradermal testing in patients with suspected allergic rhinitis and to estimate the costs to the Ontario health system of skin testing for allergic rhinitis. Methods We searched All Ovid MEDLINE, Embase, and Cochrane Database of Systematic Reviews, Database of Abstracts of Reviews of Effects, CRD Health Technology Assessment Database, Cochrane Central Register of Controlled Trials, and NHS Economic Evaluation Database for studies that evaluated the diagnostic accuracy of skin-prick and intradermal testing for allergic rhinitis using nasal provocation as the reference standard. For the clinical evidence review, data extraction and quality assessment were performed using the QUADAS-2 tool. We used the bivariate random-effects model for meta-analysis. For the economic evidence review, we assessed studies using a modified checklist developed by the (United Kingdom) National Institute for Health and Care Excellence. We estimated the annual cost of skin testing for allergic rhinitis in Ontario for 2015 to 2017 using provincial data on testing volumes and costs. Results We meta-analyzed seven studies with a total of 430 patients that assessed the accuracy of skin-prick testing. The pooled pair of sensitivity and specificity for skin-prick testing was 85% and 77%, respectively. We did not perform a meta-analysis for the diagnostic accuracy of intradermal testing due to the small number of studies (n = 4). Of these, two evaluated the accuracy of intradermal testing in confirming negative skin-prick testing results, with sensitivity ranging from 27% to 50% and specificity ranging from 60% to 100%. The other two studies evaluated the accuracy of intradermal testing as a stand-alone tool for diagnosing allergic rhinitis, with

  9. High-level verification

    CERN Document Server

    Lerner, Sorin; Kundu, Sudipta

    2011-01-01

    Given the growing size and heterogeneity of Systems on Chip (SOC), the design process from initial specification to chip fabrication has become increasingly complex. This growing complexity provides incentive for designers to use high-level languages such as C, SystemC, and SystemVerilog for system-level design. While a major goal of these high-level languages is to enable verification at a higher level of abstraction, allowing early exploration of system-level designs, the focus so far for validation purposes has been on traditional testing techniques such as random testing and scenario-based

  10. Data Exchanges and Verifications Online (DEVO)

    Data.gov (United States)

    Social Security Administration — DEVO is the back-end application for processing SSN verifications and data exchanges. DEVO uses modern technology for parameter driven processing of both batch and...

  11. IFE chamber technology testing program in NIF and chamber development test plan

    International Nuclear Information System (INIS)

    Abdou, M.A.

    1995-01-01

    Issues concerning chamber technology testing program in NIF involving: criteria for evaluation/prioritization of experiments, engineering scaling requirements for test article design and material selection and R and D plan prior to NIF testing were addressed in this paper. In order to maximize the benefits of testing program in NIF, the testing in NIF should provide the experimental data relevant to DEMO design choice or to DEMO design predictive capability by utilizing engineering scaling test article designs. Test plans were developed for 2 promising chamber design concepts. Early testing in non-fusion/non-ignition prior to testing in ignition facility serves a critical role in chamber R and D test plans in order to reduce the risks and costs of the more complex experiments in NIF

  12. Free Flight Rotorcraft Flight Test Vehicle Technology Development

    Science.gov (United States)

    Hodges, W. Todd; Walker, Gregory W.

    1994-01-01

    A rotary wing, unmanned air vehicle (UAV) is being developed as a research tool at the NASA Langley Research Center by the U.S. Army and NASA. This development program is intended to provide the rotorcraft research community an intermediate step between rotorcraft wind tunnel testing and full scale manned flight testing. The technologies under development for this vehicle are: adaptive electronic flight control systems incorporating artificial intelligence (AI) techniques, small-light weight sophisticated sensors, advanced telepresence-telerobotics systems and rotary wing UAV operational procedures. This paper briefly describes the system's requirements and the techniques used to integrate the various technologies to meet these requirements. The paper also discusses the status of the development effort. In addition to the original aeromechanics research mission, the technology development effort has generated a great deal of interest in the UAV community for related spin-off applications, as briefly described at the end of the paper. In some cases the technologies under development in the free flight program are critical to the ability to perform some applications.

  13. Analysis and testing of key technologies of PTN on MAN

    Science.gov (United States)

    Feng, Xiancheng; Chen, Ying; Cui, Wanlong

    2009-08-01

    Broadband connectivity to Internet has quickly become one of the most successful telecom service offerings ever. The meeting and marketplace of the future requires Full-Service Broadband. Full Service Broadband encompasses a unique combination of products and experience that will enable operators and network providers to meet this emerging demand for anywhere access to broadband services, quickly, cost-effectively and with minimal risk. Firstly, the standard of PTN (Packet Transmission Network) are analyzed. Then ,by deep analysis the key technology of PTN on MAN. The key technologies of PTN on MAN can be divided into two group: PBT, PBBREP, RRPP, ERP technology, and Carrier Ethernet with MPLS technology. At the same time, communication each other of MSTP and PTN,T-MPLS and IP/MPLS ,PBT and IP/MPLS are carried out by figures. At last, testing of PTN are analyzed, testing contents mainly include: TDM service function of PTN equipment, long time BER capability of STM-1service, time delay capability of PTN equipment, protection and provisioned backup path function of T-MPLS, Wrapping protection a function of T-MPLS loop network,and OAM functions.

  14. UTILITY ADVANCED TURBINE SYSTEMS (ATS) TECHNOLOGY READINESS TESTING

    Energy Technology Data Exchange (ETDEWEB)

    Unknown

    1999-10-01

    The overall objective of the Advanced Turbine System (ATS) Phase 3 Cooperative Agreement between GE and the U.S. Department of Energy (DOE) is the development of a highly efficient, environmentally superior, and cost-competitive utility ATS for base-load utility-scale power generation, the GE 7H (60 Hz) combined cycle power system, and related 9H (50 Hz) common technology. The major effort will be expended on detail design. Validation of critical components and technologies will be performed, including: hot gas path component testing, sub-scale compressor testing, steam purity test trials, and rotational heat transfer confirmation testing. Processes will be developed to support the manufacture of the first system, which was to have been sited and operated in Phase 4 but will now be sited and operated commercially by GE. This change has resulted from DOE's request to GE for deletion of Phase 4 in favor of a restructured Phase 3 (as Phase 3R) to include full speed, no load (FSNL) testing of the 7H gas turbine. Technology enhancements that are not required for the first machine design but will be critical for future ATS advances in performance, reliability, and costs will be initiated. Long-term tests of materials to confirm design life predictions will continue. A schematic of the GE H machine is shown in Figure 1-1. Information specifically related to 9H production is presented for continuity in H program reporting, but lies outside the ATS program. This report summarizes work accomplished from 4Q98 through 3Q99. The most significant accomplishments are listed.

  15. IMRT plan verification in radiotherapy

    International Nuclear Information System (INIS)

    Vlk, P.

    2006-01-01

    This article describes the procedure for verification of IMRT (Intensity modulated radiation therapy) plan, which is used in the Oncological Institute of St. Elisabeth in Bratislava. It contains basic description of IMRT technology and developing a deployment plan for IMRT planning system CORVUS 6.0, the device Mimic (Multilammelar intensity modulated collimator) and the overall process of verifying the schedule created. The aim of verification is particularly good control of the functions of MIMIC and evaluate the overall reliability of IMRT planning. (author)

  16. Development of tritium technology at the Tritium Systems Test Assembly

    International Nuclear Information System (INIS)

    Anderson, J.L.; Bartlit, J.R.

    1982-01-01

    The Tritium Systems Test Assembly (TSTA) at the Los Alamos National Laboratory is dedicated to the development, demonstration, and interfacing of technologies related to the deuterium-tritium fuel cycle for large scale fusion reactor systems starting with the Fusion Engineering Device (FED) or the International Tokamak Reactor (INTOR). This paper briefly describes the fuel cycle and safety systems at TSTA including the Vacuum Facility, Fuel Cleanup, Isotope Separation, Transfer Pumping, Emergency Tritium Cleanup, Tritium Waste Treatment, Tritium Monitoring, Data Acquisition and Control, Emergency Power and Gas Analysis systems. Discussed in further detail is the experimental program proposed for the startup and testing of these systems

  17. UTILITY ADVANCED TURBINE SYSTEMS(ATS) TECHNOLOGY READINESS TESTING

    Energy Technology Data Exchange (ETDEWEB)

    Kenneth A. Yackly

    2001-06-01

    The following paper provides an overview of GE's H System{trademark} technology, and specifically, the design, development, and test activities associated with the DOE Advanced Turbine Systems (ATS) program. There was intensive effort expended in bringing this revolutionary advanced technology program to commercial reality. In addition to describing the magnitude of performance improvement possible through use of H System{trademark} technology, this paper discusses the technological milestones during the development of the first 9H (50Hz) and 7H (60 Hz) gas turbines. To illustrate the methodical product development strategy used by GE, this paper discusses several technologies that were essential to the introduction of the H System{trademark}. Also included are analyses of the series of comprehensive tests of materials, components and subsystems that necessarily preceded full scale field testing of the H System{trademark}. This paper validates one of the basic premises with which GE started the H System{trademark} development program: exhaustive and elaborate testing programs minimized risk at every step of this process, and increase the probability of success when the H System{trademark} is introduced into commercial service. In 1995, GE, the world leader in gas turbine technology for over half a century, in conjunction with the DOE National Energy Technology Laboratory's ATS program, introduced its new generation of gas turbines. This H System{trademark} technology is the first gas turbine ever to achieve the milestone of 60% fuel efficiency. Because fuel represents the largest individual expense of running a power plant, an efficiency increase of even a single percentage point can substantially reduce operating costs over the life of a typical gas-fired, combined-cycle plant in the 400 to 500 megawatt range. The H System{trademark} is not simply a state-of-the-art gas turbine. It is an advanced, integrated, combined-cycle system in which every

  18. Structural Verification of the First Orbital Wonder of the World - The Structural Testing and Analysis of the International Space Station (ISS)

    Science.gov (United States)

    Zipay, John J.; Bernstein, Karen S.; Bruno, Erica E.; Deloo, Phillipe; Patin, Raymond

    2012-01-01

    The International Space Station (ISS) can be considered one of the structural engineering wonders of the world. On par with the World Trade Center, the Colossus of Rhodes, the Statue of Liberty, the Great Pyramids, the Petronas towers and the Burj Khalifa skyscraper of Dubai, the ambition and scope of the ISS structural design, verification and assembly effort is a truly global success story. With its on-orbit life projected to be from its beginning in 1998 to the year 2020 (and perhaps beyond), all of those who participated in its development can consider themselves part of an historic engineering achievement representing all of humanity. The structural design and verification of the ISS could be the subject of many scholarly papers. Several papers have been written on the structural dynamic characterization of the ISS once it was assembled on-orbit [1], but the ground-based activities required to assure structural integrity and structural life of the individual elements from delivery to orbit through assembly and planned on-orbit operations have never been totally summarized. This paper is intended to give the reader an overview of some of the key decisions made during the structural verification planning for the elements of the U.S. On-Orbit Segment (USOS) as well as to summarize the many structural tests and structural analyses that were performed on its major elements. An effort is made for this paper to be summarily comprehensive, but as with all knowledge capture efforts of this kind, there are bound to be errors of omission. Should the reader discover any of these, please feel free to contact the principal author. The ISS (Figure 1) is composed of pre-integrated truss segments and pressurized elements supplied by NASA, the Russian Federal Space Agency (RSA), the European Space Agency (ESA) and the Japanese Aerospace Exploration Agency (JAXA). Each of these elements was delivered to orbit by a launch vehicle and connected to one another either robotically or

  19. University of Florida Torsion Pendulum for Testing Key LISA Technology

    Science.gov (United States)

    Apple, Stephen; Chilton, Andrew; Olatunde, Taiwo Janet; Hillsberry, Daniel; Parry, Samantha; Ciani, Giacomo; Wass, Peter; Mueller, Guido; Conklin, John

    2018-01-01

    This presentation will describe the design and performance of a new torsion pendulum at the University of Florida used for testing inertial sensors and associated technologies for use in space – based gravitational wave observatories and geodesy missions. In particular this new torsion pendulum facility is testing inertial sensors and associated technology for the upcoming LISA (laser interferometer space antenna) space-based gravitational wave observatory mission. The torsion pendulum apparatus is comprised of a suspended cross bar assembly that has LISA test mass mockups at each of its ends. Two of the test mass mockups are enclosed by capacitive sensors which provide actuation and position sensing. The entire assembly is housed in a vacuum chamber. The pendulum cross-bar converts rotational motion of the test masses about the suspension fiber axis into translational motion. The 22 cm cross bar arm length along with the extremely small torsional spring constant of the suspension fiber results in a near free fall condition in the translational degree-of-freedom orthogonal to both the member and the suspension fiber. The test masses are electrically isolated from the pendulum assembly and their charge is controlled via photoemission using fiber coupled UV LEDS. Position of the test masses is measured using both capacitive and interferometric readout. The broadband sensitivity of the capacitive readout and laser interferometer readout is 30 nm/√Hz and 0.5 nm/√Hz respectively. The performance of the pendulum measured in equivalent acceleration noise acting on a LISA test mass is approximately 3 × 10-13 ms-2/√Hz at 2 mHz. This presentation will also discuss the design and fabrication of a flight-like gravitational reference sensor that will soon be integrated into the torsion pendulum facility. This flight-like GRS will allow for noise performance measurements in a more LISA-like configuration.

  20. Full-Scale Testing of Pipeline Unplugging Technologies - NuVision's Fluidic Wave-Action Technology

    International Nuclear Information System (INIS)

    Gokaltun, S.; McDaniel, D.; Varona, J.; Patel, R.; Awwad, A.; Roelant, D.; Keszler, E.

    2009-01-01

    In this paper, we present a technical evaluation of a pipeline unplugging method that can be used as a feasible tool to clean fouled pipes at Department of Energy (DOE) sites. The unplugging method depends on running water against the plugged section in the pipeline for multiple times and breaking the mechanical bonds of the material that hold the plug together. The working principles of the method are similar to beach erosion since a water wave is generated using the suction and drive mechanisms caused by the system in the pipeline that erodes the plug from one end. The technology tested also is capable of creating an external force on the plug that helps the unplugging process however this characteristic of the technology was not tested during the testing reported in this work. More focus was given to the erosion capability of the technology and how wave characteristics affected that. Results obtained demonstrated that there is a correlation between the suction and drive characteristics of the wave generated in the pipeline with the maximum pressures attained in the plug region, the velocity of the wave prior to colliding with the plug and the erosion. It was found that the technology was most effective in unplugging Phosphate based chemical plugs and Kaolin clay based plugs while it took more time to erode Aluminum based plugs for the same pipeline test layouts. (authors)

  1. Understanding Student Teachers’ Behavioural Intention to Use Technology: Technology Acceptance Model (TAM Validation and Testing

    Directory of Open Access Journals (Sweden)

    Kung-Teck, Wong

    2013-01-01

    Full Text Available This study sets out to validate and test the Technology Acceptance Model (TAM in the context of Malaysian student teachers’ integration of their technology in teaching and learning. To establish factorial validity, data collected from 302 respondents were tested against the TAM using confirmatory factor analysis (CFA, and structural equation modelling (SEM was used for model comparison and hypotheses testing. The goodness-of-fit test of the analysis shows partial support of the applicability of the TAM in a Malaysian context. Overall, the TAM accounted for 37.3% of the variance in intention to use technology among student teachers and of the five hypotheses formulated, four are supported. Perceived usefulness is a significant influence on attitude towards computer use and behavioural intention. Perceived ease of use significantly influences perceived usefulness, and finally, behavioural intention is found to be influenced by attitude towards computer use. The findings of this research contribute to the literature by validating the TAM in the Malaysian context and provide several prominent implications for the research and practice of technology integration development.

  2. Future directions of nuclear verification

    International Nuclear Information System (INIS)

    Blix, H.

    1997-01-01

    Future directions of nuclear verification are discussed including the following topics: verification of non-proliferation commitments; practicalities of strengthening safeguards; new tasks in nuclear verification

  3. UTILITY ADVANCED TURBINE SYSTEMS (ATS) TECHNOLOGY READINESS TESTING

    Energy Technology Data Exchange (ETDEWEB)

    Unknown

    1999-04-01

    The overall objective of the Advanced Turbine System (ATS) Phase 3 Cooperative Agreement between GE and the U.S. Department of Energy (DOE) is the development of the GE 7H and 9H combined cycle power systems. The major effort will be expended on detail design. Validation of critical components and technologies will be performed, including: hot gas path component testing, sub-scale compressor testing, steam purity test trials, and rotational heat transfer conflation testing. Processes will be developed to support the manufacture of the first system, which was to have been sited and operated in Phase 4 but will now be sited and operated commercially by GE. This change has resulted from DOE's request to GE for deletion of Phase 4 in favor of a restructured Phase 3 (as Phase 3R) to include full speed, no load (FSNL) testing of the 7H gas turbine. Technology enhancements that are not required for the first machine design but will be critical for future ATS advances in performance, reliability, and costs will be initiated. Long-term tests of materials to confirm design life predictions will continue. The objective of this task is to design 7H and 9H compressor rotor and stator structures with the goal of achieving high efficiency at lower cost and greater durability by applying proven GE Power Systems (GEPS) heavy-duty use design practices. The designs will be based on the GE Aircraft Engines (GEAE) CF6-80C2 compressor. Transient and steady-state thermo-mechanical stress analyses will be run to ensure compliance with GEPS life standards. Drawings will be prepared for forgings, castings, machining, and instrumentation for full speed, no load (FSNL) tests of the first unit on both 9H and 7H applications.

  4. Design for Verification: Enabling Verification of High Dependability Software-Intensive Systems

    Science.gov (United States)

    Mehlitz, Peter C.; Penix, John; Markosian, Lawrence Z.; Koga, Dennis (Technical Monitor)

    2003-01-01

    Strategies to achieve confidence that high-dependability applications are correctly implemented include testing and automated verification. Testing deals mainly with a limited number of expected execution paths. Verification usually attempts to deal with a larger number of possible execution paths. While the impact of architecture design on testing is well known, its impact on most verification methods is not as well understood. The Design for Verification approach considers verification from the application development perspective, in which system architecture is designed explicitly according to the application's key properties. The D4V-hypothesis is that the same general architecture and design principles that lead to good modularity, extensibility and complexity/functionality ratio can be adapted to overcome some of the constraints on verification tools, such as the production of hand-crafted models and the limits on dynamic and static analysis caused by state space explosion.

  5. Standard practice for verification of testing frame and specimen alignment under tensile and compressive axial force application

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 Included in this practice are methods covering the determination of the amount of bending that occurs during the application of tensile and compressive forces to notched and unnotched test specimens in the elastic range and to plastic strains less than 0.002. These methods are particularly applicable to the force application rates normally used for tension testing, creep testing, and uniaxial fatigue testing.

  6. Integrated testing strategies for toxicity employing new and existing technologies.

    Science.gov (United States)

    Combes, Robert D; Balls, Michael

    2011-07-01

    We have developed individual, integrated testing strategies (ITS) for predicting the toxicity of general chemicals, cosmetics, pharmaceuticals, inhaled chemicals, and nanoparticles. These ITS are based on published schemes developed previously for the risk assessment of chemicals to fulfil the requirements of REACH, which have been updated to take account of the latest developments in advanced in chemico modelling and in vitro technologies. In addition, we propose an ITS for neurotoxicity, based on the same principles, for incorporation in the other ITS. The technologies are deployed in a step-wise manner, as a basis for decision-tree approaches, incorporating weight-of-evidence stages. This means that testing can be stopped at the point where a risk assessment and/or classification can be performed, with labelling in accordance with the requirements of the regulatory authority concerned, rather than following a checklist approach to hazard identification. In addition, the strategies are intelligent, in that they are based on the fundamental premise that there is no hazard in the absence of exposure - which is why pharmacokinetic modelling plays a key role in each ITS. The new technologies include the use of complex, three-dimensional human cell tissue culture systems with in vivo-like structural, physiological and biochemical features, as well as dosing conditions. In this way, problems of inter-species extrapolation and in vitro/in vivo extrapolation are minimised. This is reflected in the ITS placing more emphasis on the use of volunteers at the whole organism testing stage, rather than on existing animal testing, which is the current situation. 2011 FRAME.

  7. Structural testing of the technology integration box beam

    Science.gov (United States)

    Griffin, C. F.

    1992-01-01

    A full-scale section of a transport aircraft wing box was designed, analyzed, fabricated, and tested. The wing box section, which was called the technology integration box beam, contained blade stiffened covers and T-stiffened channel spars constructed using graphite/epoxy materials. Covers, spars, and the aluminum ribs were assembled using mechanical fasteners. The box beam was statically tested for several loading conditions to verify the stiffness and strength characteristics of the composite wing design. Failure of the box beam occurred at 125 percent of design limit load during the combined upbending and torsion ultimate design load test. It appears that the failure initiated at a stiffener runout location in the upper cover which resulted in rupture of the upper cover and portions of both spars.

  8. Pseudoisochromatic test plate colour representation dependence on printing technology

    International Nuclear Information System (INIS)

    Luse, K; Ozolinsh, M; Fomins, S

    2012-01-01

    The aim of the study is to determine best printing technology for creation of colour vision deficiency tests. Valid tests for protanopia and deuteranopia were created from perceived colour matching experiments from printed colour samples by colour deficient individuals. Calibrated EpsonStylus Pro 7800 printer for ink prints and Noritsu HD 3701 digital printer for photographic prints were used. Multispectral imagery (by tunable liquid crystal filters system CRI Nuance Vis 07) data analysis show that in case of ink prints, the measured pixel colour coordinate dispersion (in the CIExy colour diagram) of similar colour arrays is smaller than in case of photographic printing. The print quality in terms of colour coordinate dispersion for printing methods used is much higher than in case of commercially available colour vision deficiency tests.

  9. 77 FR 16868 - Quality Verification for Plate-Type Uranium-Aluminum Fuel Elements for Use in Research and Test...

    Science.gov (United States)

    2012-03-22

    ... Fuel Elements for Use in Research and Test Reactors AGENCY: Nuclear Regulatory Commission. ACTION... Plate-Type Uranium-Aluminum Fuel Elements for Use in Research and Test Reactors.'' This guide describes... plate-type uranium-aluminum fuel elements used in research and test reactors (RTRs). DATES: Submit...

  10. HTGR analytical methods and design verification

    International Nuclear Information System (INIS)

    Neylan, A.J.; Northup, T.E.

    1982-05-01

    Analytical methods for the high-temperature gas-cooled reactor (HTGR) include development, update, verification, documentation, and maintenance of all computer codes for HTGR design and analysis. This paper presents selected nuclear, structural mechanics, seismic, and systems analytical methods related to the HTGR core. This paper also reviews design verification tests in the reactor core, reactor internals, steam generator, and thermal barrier

  11. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Performance Verification Report: Final Comprehensive Performance Test Report, P/N 1331720-2TST, S/N 105/A1

    Science.gov (United States)

    Platt, R.

    1999-01-01

    This is the Performance Verification Report, Final Comprehensive Performance Test (CPT) Report, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A). This specification establishes the requirements for the CPT and Limited Performance Test (LPT) of the AMSU-1A, referred to here in as the unit. The sequence in which the several phases of this test procedure shall take place is shown.

  12. Verification of industrial x-ray machine: MINTs experience

    International Nuclear Information System (INIS)

    Aziz Amat; Saidi Rajab; Eesan Pasupathi; Saipo Bahari Abdul Ratan; Shaharudin Sayuti; Abd Nassir Ibrahim; Abd Razak Hamzah

    2005-01-01

    Radiation and electrical safety of the industrial x-ray equipment required to meet Atomic Energy Licensing Board(AELB) guidelines ( LEM/TEK/42 ) at the time of installation and subsequently a periodic verification should be ensured. The purpose of the guide is to explain the requirements employed in conducting the test on industrial x-ray apparatus and be certified in meeting with our local legislative and regulation. Verification is aimed to provide safety assurance information on electrical requirements and the minimum radiation exposure to the operator. This regulation is introduced on new models imported into the Malaysian market. Since June, 1997, Malaysian Institute for Nuclear Technology Research (MINT) has been approved by AELB to provide verification services to private company, government and corporate body throughout Malaysia. Early January 1997, AELB has made it mandatory that all x-ray equipment for industrial purpose (especially Industrial Radiography) must fulfill certain performance test based on the LEM/TEK/42 guidelines. MINT as the third party verification encourages user to improve maintenance of the equipment. MINT experiences in measuring the performance on intermittent and continuous duty rating single-phase industrial x-ray machine in the year 2004 indicated that all of irradiating apparatus tested pass the test and met the requirements of the guideline. From MINT record, 1997 to 2005 , three x-ray models did not meet the requirement and thus not allowed to be used unless the manufacturers willing to modify it to meet AELB requirement. This verification procedures on electrical and radiation safety on industrial x-ray has significantly improved the the maintenance cultures and safety awareness in the usage of x-ray apparatus in the industrial environment. (Author)

  13. On Masculinities, Technologies and Pain: The Testing of Male Contraceptives Technologies in the Clinic and the Media

    NARCIS (Netherlands)

    Oudshoorn, Nelly E.J.

    1999-01-01

    In the last fifteen years, testing has attracted much attention in science and technology studies. Most researchers have focused almost exclusively on testing in the laboratory, specifically designed test locations, and, for medical technologies, the clinic. What counts as testing has largely been

  14. Test results, Industrial Solar Technology parabolic trough solar collector

    Energy Technology Data Exchange (ETDEWEB)

    Dudley, V.E. [EG and G MSI, Albuquerque, NM (United States); Evans, L.R.; Matthews, C.W. [Sandia National Labs., Albuquerque, NM (United States)

    1995-11-01

    Sandia National Laboratories and Industrial Solar Technology are cost-sharing development of advanced parabolic trough technology. As part of this effort, several configurations of an IST solar collector were tested to determine the collector efficiency and thermal losses with black chrome and black nickel receiver selective coatings, combined with aluminized film and silver film reflectors, using standard Pyrex{reg_sign} and anti-reflective coated Pyrex{reg_sign} glass receiver envelopes. The development effort has been successful, producing an advanced collector with 77% optical efficiency, using silver-film reflectors, a black nickel receiver coating, and a solgel anti-reflective glass receiver envelope. For each receiver configuration, performance equations were empirically derived relating collector efficiency and thermal losses to the operating temperature. Finally, equations were derived showing collector performance as a function of input insolation value, incident angle, and operating temperature.

  15. Parking Space Verification

    DEFF Research Database (Denmark)

    Høg Peter Jensen, Troels; Thomsen Schmidt, Helge; Dyremose Bodin, Niels

    2018-01-01

    With the number of privately owned cars increasing, the issue of locating an available parking space becomes apparant. This paper deals with the verification of vacant parking spaces, by using a vision based system looking over parking areas. In particular the paper proposes a binary classifier...... system, based on a Convolutional Neural Network, that is capable of determining if a parking space is occupied or not. A benchmark database consisting of images captured from different parking areas, under different weather and illumination conditions, has been used to train and test the system...

  16. Independent verification survey report for exposure units Z2-24, Z2-31, Z2-32, AND Z2-36 in zone 2 of the East Tennessee technology park Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    King, David A. [Oak Ridge Inst. for Science and Education (ORISE), Oak Ridge, TN (United States)

    2013-10-01

    The U.S. Department of Energy (DOE) Oak Ridge Office of Environmental Management selected Oak Ridge Associated Universities (ORAU), through the Oak Ridge Institute for Science and Education (ORISE) contract, to perform independent verification (IV) at Zone 2 of the East Tennessee Technology Park (ETTP) in Oak Ridge, Tennessee. ORAU has concluded IV surveys, per the project-specific plan (PSP) (ORAU 2013a) covering exposure units (EUs) Z2-24, -31, -32, and -36. The objective of this effort was to verify the target EUs comply with requirements in the Zone 2 Record of Decision (ROD) (DOE 2005), as implemented by using the dynamic verification strategy presented in the dynamic work plan (DWP) (BJC 2007); and confirm commitments in the DWP were adequately implemented, as verified via IV surveys and soil sampling.

  17. Exploratory battery technology development and testing report for 1989

    Energy Technology Data Exchange (ETDEWEB)

    Magnani, N.J.; Diegle, R.B.; Braithwaite, J.W.; Bush, D.M.; Freese, J.M.; Akhil, A.A.; Lott, S.E.

    1990-12-01

    Sandia National Laboratories, Albuquerque, has been designated as Lead Center for the Exploratory Battery Technology Development and Testing Project, which is sponsored by the US Department of Energy's Office of Energy Storage and Distribution. In this capacity, Sandia is responsible for the engineering development of advanced rechargeable batteries for both mobile and stationary energy storage applications. This report details the technical achievements realized in pursuit of the Lead Center's goals during calendar year 1989. 4 refs., 84 figs., 18 tabs.

  18. Mammalian Toxicology Testing: Problem Definition Study, Technology Changes Impact on Testing Requirements.

    Science.gov (United States)

    1981-01-01

    Ecotoxicology and Env. Safety 1:151-173. 67 TR-477-14-12 FORECAST OF POTENTIAL TECHNOLOGY CHANGES THAT 1AY IMPACT TOXICOLOGICAL TESTING REQUIREMENTS...subjects for many years after exposure. Aside from pharmaceutical compounds, most people are not exposed directly to chemicals, except in occupational

  19. Software verification for nuclear industry

    International Nuclear Information System (INIS)

    Wilburn, N.P.

    1985-08-01

    Why verification of software products throughout the software life cycle is necessary is considered. Concepts of verification, software verification planning, and some verification methodologies for products generated throughout the software life cycle are then discussed

  20. Drive-train dynamics technology - State-of-the-art and design of a test facility for advanced development

    Science.gov (United States)

    Badgley, R. H.; Fleming, D. P.; Smalley, A. J.

    1975-01-01

    A program for the development and verification of drive-train dynamic technology is described along with its basis and the results expected from it. A central feature of this program is a drive-train test facility designed for the testing and development of advanced drive-train components, including shaft systems, dampers, and couplings. Previous efforts in designing flexible dynamic drive-train systems are reviewed, and the present state of the art is briefly summarized. The design of the test facility is discussed with major attention given to the formulation of the test-rig concept, dynamic scaling of model shafts, and the specification of design parameters. Specific efforts envisioned for the test facility are briefly noted, including evaluations of supercritical test shafts, stability thresholds for various sources and types of instabilities that can exist in shaft systems, effects of structural flexibility on the dynamic performance of dampers, and methods for vibration control in two-level and three-level flexible shaft systems.

  1. Three-Dimensional Model Test Verification of the New Cubipod Armoured Western Breakwater for Port of Hanstholm

    DEFF Research Database (Denmark)

    Eldrup, Mads Røge; Andersen, Thomas Lykke

    The present report presents results from a three-dimensional model test study carried out at Aalborg University in January 2018 with the new western breakwater in Port of Hanstholm as proposed by the contractor Aarsleff and their consultant Cowi. The objectives of the model tests were to study th...

  2. Verifying disarmament: scientific, technological and political challenges

    Energy Technology Data Exchange (ETDEWEB)

    Pilat, Joseph R [Los Alamos National Laboratory

    2011-01-25

    There is growing interest in, and hopes for, nuclear disarmament in governments and nongovernmental organizations (NGOs) around the world. If a nuclear-weapon-free world is to be achievable, verification and compliance will be critical. VerifYing disarmament would have unprecedented scientific, technological and political challenges. Verification would have to address warheads, components, materials, testing, facilities, delivery capabilities, virtual capabilities from existing or shutdown nuclear weapon and existing nuclear energy programs and material and weapon production and related capabilities. Moreover, it would likely have far more stringent requirements. The verification of dismantlement or elimination of nuclear warheads and components is widely recognized as the most pressing problem. There has been considerable research and development done in the United States and elsewhere on warhead and dismantlement transparency and verification since the early 1990s. However, we do not today know how to verifY low numbers or zero. We need to develop the needed verification tools and systems approaches that would allow us to meet this complex set of challenges. There is a real opportunity to explore verification options and, given any realistic time frame for disarmament, there is considerable scope to invest resources at the national and international levels to undertake research, development and demonstrations in an effort to address the anticipated and perhaps unanticipated verification challenges of disarmament now andfor the next decades. Cooperative approaches have the greatest possibility for success.

  3. Advanced verification methods for OVI security ink

    Science.gov (United States)

    Coombs, Paul G.; McCaffery, Shaun F.; Markantes, Tom

    2006-02-01

    OVI security ink +, incorporating OVP security pigment* microflakes, enjoys a history of effective document protection. This security feature provides not only first-line recognition by the person on the street, but also facilitates machine-readability. This paper explores the evolution of OVI reader technology from proof-of-concept to miniaturization. Three different instruments have been built to advance the technology of OVI machine verification. A bench-top unit has been constructed which allows users to automatically verify a multitude of different banknotes and OVI images. In addition, high speed modules were fabricated and tested in a state of the art banknote sorting machine. Both units demonstrate the ability of modern optical components to illuminate and collect light reflected from the interference platelets within OVI ink. Electronic hardware and software convert and process the optical information in milliseconds to accurately determine the authenticity of the security feature. Most recently, OVI ink verification hardware has been miniaturized and simplified providing yet another platform for counterfeit protection. These latest devices provide a tool for store clerks and bank tellers to unambiguously determine the validity of banknotes in the time period it takes the cash drawer to be opened.

  4. Verification of ceramic structures

    NARCIS (Netherlands)

    Behar-Lafenetre, S.; Cornillon, L.; Rancurel, M.; Graaf, D. de; Hartmann, P.; Coe, G.; Laine, B.

    2012-01-01

    In the framework of the "Mechanical Design and Verification Methodologies for Ceramic Structures" contract [1] awarded by ESA, Thales Alenia Space has investigated literature and practices in affiliated industries to propose a methodological guideline for verification of ceramic spacecraft and

  5. Verification and disarmament

    International Nuclear Information System (INIS)

    Blix, H.

    1998-01-01

    The main features are described of the IAEA safeguards verification system that non-nuclear weapon states parties of the NPT are obliged to accept. Verification activities/problems in Iraq and North Korea are discussed

  6. Verification and disarmament

    Energy Technology Data Exchange (ETDEWEB)

    Blix, H. [IAEA, Vienna (Austria)

    1998-07-01

    The main features are described of the IAEA safeguards verification system that non-nuclear weapon states parties of the NPT are obliged to accept. Verification activities/problems in Iraq and North Korea are discussed.

  7. Letter report: Evaluation of dryer/calciner technologies for testing

    International Nuclear Information System (INIS)

    Sevigny, G.

    1996-02-01

    This letter report describes some past experiences on the drying and calcination of radioactive materials or corresponding simulants; and the information needed from testing. The report also includes an assessment of informational needs including possible impacts to a full-scale plant. This includes reliability, maintenance, and overall size versus throughput. Much of the material was previously compiled and reported by Mike Elliott of PNL open-quotes Melter Performance Assessmentclose quotes and Larry Eisenstatt of SEG on contract to WHC in a letter to Rod Powell. Also, an annotated bibliography was prepared by Reagan Seymour of WHC. Descriptions of the drying and calciner technologies, development status, advantages and disadvantages of using a WFE or calciner, and recommendations for future testing are discussed in this report

  8. Miniature specimen technology for postirradiation fatigue crack growth testing

    International Nuclear Information System (INIS)

    Mervyn, D.A.; Ermi, A.M.

    1979-01-01

    Current magnetic fusion reactor design concepts require that the fatigue behavior of candidate first wall materials be characterized. Fatigue crack growth may, in fact, be the design limiting factor in these cyclic reactor concepts given the inevitable presence of crack-like flaws in fabricated sheet structures. Miniature specimen technology has been developed to provide the large data base necessary to characterize irradiation effects on the fatigue crack growth behavior. An electrical potential method of measuring crack growth rates is employed on miniature center-cracked-tension specimens (1.27 cm x 2.54 cm x 0.061 cm). Results of a baseline study on 20% cold-worked 316 stainless steel, which was tested in an in-cell prototypic fatigue machine, are presented. The miniature fatigue machine is designed for low cost, on-line, real time testing of irradiated fusion candidate alloys. It will enable large scale characterization and development of candidate first wall alloys

  9. Operational lessons learned in conducting a multi-country collaboration for vaccine safety signal verification and hypothesis testing: The global vaccine safety multi country collaboration initiative.

    Science.gov (United States)

    Guillard-Maure, Christine; Elango, Varalakshmi; Black, Steven; Perez-Vilar, Silvia; Castro, Jose Luis; Bravo-Alcántara, Pamela; Molina-León, Helvert Felipe; Weibel, Daniel; Sturkenboom, Miriam; Zuber, Patrick L F

    2018-01-08

    Timely and effective evaluation of vaccine safety signals for newly developed vaccines introduced in low and middle- income countries (LMICs) is essential. The study tested the development of a global network of hospital-based sentinel sites for vaccine safety signal verification and hypothesis testing. Twenty-six sentinel sites in sixteen countries across all WHO regions participated, and 65% of the sites were from LMIC. We describe the process for the establishment and operationalization of such a network and the lessons learned in conducting a multi-country collaborative initiative. 24 out of the 26 sites successfully contributed data for the global analysis using standardised tools and procedures. Our study successfully confirmed the well-known risk estimates for the outcomes of interest. The main challenges faced by investigators were lack of adequate information in the medical records for case ascertainment and classification, and access to immunization data. The results suggest that sentinel hospitals intending to participate in vaccine safety studies strengthen their systems for discharge diagnosis coding, medical records and linkage to vaccination data. Our study confirms that a multi-country hospital-based network initiative for vaccine safety monitoring is feasible and demonstrates the validity and utility of large collaborative international studies to monitor the safety of new vaccines introduced in LMICs. Copyright © 2017. Published by Elsevier Ltd.

  10. The development of advanced instrumentation and control technology. The development of verification and validation technology for instrumentation and control in NPPs

    International Nuclear Information System (INIS)

    Kwon, Kee Choon; Ham, Chang Shik; Lee, Jang Soo; Kim, Jang Yeol; Song, Soon Ja; Kim, Jung Taek; Park, Won Man; Lee, Dong Young; Eom, Heung Seop; Park, Kee Yong.

    1997-07-01

    We found essential problems followed by digitalizing of instrumentation and control. A scheme is divided into hardware and software to resolve these problems. We have analyzed the hardware V and V methodologies about common mode failure, commercial grade dedication process and electromagnetic compatibility. We have developed several guidelines, the software classification guideline, the quality assurance handbook for the software in digital I and C, the software V and V planning guideline, and the software safety guideline. And then, we have established the integrated environment for the safety-critical software based on the Computer Aided Software Engineering (CASE) tools. We have also surveyed a trend and application case of test facility for establishment of functional requirements. Input/output interface which connects among the host computer and developed target and panel are designed and manufactured using UXI bus. The developed functional test facility is used for test and validate the automatic start-up intelligent control system, the dynamic alarm system, the accident identification system using hidden Markov model, and the intelligent logic tracking system. The result of evaluation of the above systems shows the functional test facility performance is sufficient in normal operating and transient conditions. (author). 24 tabs., 59 figs

  11. Two-Dimensional Model Test Verification of the New Cubipod Armoured Western Breakwater for the Port of Hanstholm

    DEFF Research Database (Denmark)

    Eldrup, Mads Røge; Andersen, Thomas Lykke

    The present report presents results from a two-dimensional model test study carried out at Aalborg University in December 2017 with the proposed trunk section for the new cubipod armoured western breakwater in Port of Hanstholm as proposed by the contractor Aarsleff and their consultant Cowi....... The objectives of the model tests were to study the stability of the armour layer, toe erosion, overtopping and transmission. The scale used for the model tests was 1:44.6. Initially the model was created on a scale 1:47, but model was adapted to 1:44.6 due to a mismatch in density of rented cupipods. Unless...

  12. Technology and testing for the extension of plant life

    International Nuclear Information System (INIS)

    Blumer, U.R.; Edelmann, X.

    1988-01-01

    This paper describes selected portions of a recommended program for the application of equipment-manufacturing-related technology and testing for the extension of life for operating nuclear power plants. It is appropriate to mention that the Swiss nuclear plants, their staffs, and the supporting Swiss nuclear industry are rightfully proud of their record of performance. Plant staffs have been intimately involved in system and equipment design and engineering from the very beginnings of their plants. Maintenance of the plant systems and equipment is referred to as engineering rather than maintenance, because it is viewed as a technical effort and an extension of the original plant and equipment design and construction effort. Care, competence, cleanliness, and attention to detail have been bywords for the Swiss plants. Success has been demonstrated through enviable availability performance. With operation and availability capability already demonstrated, the Swiss are now turning their attention to the extension of plant life. This summary describes some aspects of this work, which is fundamentally based on the application of technology and testing skills developed for equipment manufacture and the original installation of this equipment in the plants, but has been enhanced by research and development (R and D) and an ongoing effort to serve utilities in their maintenance activities

  13. Business of Nuclear Safety Analysis Office, Nuclear Technology Test Center

    International Nuclear Information System (INIS)

    Hayakawa, Masahiko

    1981-01-01

    The Nuclear Technology Test Center established the Nuclear Safety Analysis Office to execute newly the works concerning nuclear safety analysis in addition to the works related to the proving tests of nuclear machinery and equipments. The regulations for the Nuclear Safety Analysis Office concerning its organization, business and others were specially decided, and it started the business formally in August, 1980. It is a most important subject to secure the safety of nuclear facilities in nuclear fuel cycle as the premise of developing atomic energy. In Japan, the strict regulation of safety is executed by the government at each stage of the installation, construction, operation and maintenance of nuclear facilities, based on the responsibility for the security of installers themselves. The Nuclear Safety Analysis Office was established as the special organ to help the safety examination related to the installation of nuclear power stations and others by the government. It improves and puts in order the safety analysis codes required for the cross checking in the safety examination, and carries out safety analysis calculation. It is operated by the cooperation of the Science and Technology Agency and the Agency of Natural Resources and Energy. The purpose of establishment, the operation and the business of the Nuclear Safety Analysis Office, the plan of improving and putting in order of analysis codes, and the state of the similar organs in foreign countries are described. (Kako, I.)

  14. Demonstration plant Neunburg vorm Wald for testing solar hydrogen technologies

    International Nuclear Information System (INIS)

    Szyszka, A.

    1992-01-01

    Demonstration plant Neunburg vorm Wald for testing solar hydrogen technologies. The Solar-Wasserstoff-Bayern GmbH (SWB), an associated company of the associate Bayernwerk AG (share of 60%), BMW INTEC Beteiligungs GmbH, Linde AG, MBB GmbH and Siemens AG (10% of each share) founded at the end of 1986, realizes, operates and supplements a demonstration plant in Neunburg vorm Wald, for which in a commercially feasible dimension important system steps are tested oriented to the practice in their combination with regard to energy management based on hydrogen as energy source. The project is planned for a long term separated into single project phases. The investment volume of about 64 millions estimated in October 1987 is kept well from the present view for phase 1, reaching to the end of 1991. The Federal Ministry for Research and Technology (BMFT) and the Bavarian State Ministry for Economy and Traffic (B ST MWV) support the part width to be subsidized of 35% and 15% respectively. (orig.) [de

  15. Altered gas-exchange at peak exercise in obese adolescents: implications for verification of effort during cardiopulmonary exercise testing.

    Science.gov (United States)

    Marinus, Nastasia; Bervoets, Liene; Massa, Guy; Verboven, Kenneth; Stevens, An; Takken, Tim; Hansen, Dominique

    2017-12-01

    Cardiopulmonary exercise testing is advised ahead of exercise intervention in obese adolescents to assess medical safety of exercise and physical fitness. Optimal validity and reliability of test results are required to identify maximal exercise effort. As fat oxidation during exercise is disturbed in obese individuals, it remains an unresolved methodological issue whether the respiratory gas exchange ratio (RER) is a valid marker for maximal effort during exercise testing in this population. RER during maximal exercise testing (RERpeak), and RER trajectories, was compared between obese and lean adolescents and relationships between RERpeak, RER slope and subject characteristics (age, gender, Body Mass Index [BMI], Tanner stage, physical activity level) were explored. Thirty-four obese (BMI: 35.1±5.1 kg/m²) and 18 lean (BMI: 18.8±1.9 kg/m²) adolescents (aged 12-18 years) performed a maximal cardiopulmonary exercise test on bike, with comparison of oxygen uptake (VO2), heart rate (HR), expiratory volume (VE), carbon dioxide output (VCO2), and cycling power output (W). RERpeak (1.09±0.06 vs. 1.14±0.06 in obese vs. lean adolescents, respectively) and RER slope (0.03±0.01 vs. 0.05±0.01 per 10% increase in VO2, in obese vs. lean adolescents, respectively) was significantly lower in obese adolescents, and independently related to BMI (Pimportant methodological implications for cardiopulmonary exercise testing in this population.

  16. DIESEL ENGINE RETROFIT TECHNOLOGY VERIFICATION

    Science.gov (United States)

    This presentation wil be given at the EPA Science Forum 2005 in Washington, DC. According to recent estimates, there are approximately 7.9 million heavy-duty diesel trucks and buses in use in the United States. Emissions from these vehicles account for substantial portions of t...

  17. CTBT Integrated Verification System Evaluation Model

    Energy Technology Data Exchange (ETDEWEB)

    Edenburn, M.W.; Bunting, M.L.; Payne, A.C. Jr.

    1997-10-01

    Sandia National Laboratories has developed a computer based model called IVSEM (Integrated Verification System Evaluation Model) to estimate the performance of a nuclear detonation monitoring system. The IVSEM project was initiated in June 1994, by Sandia`s Monitoring Systems and Technology Center and has been funded by the US Department of Energy`s Office of Nonproliferation and National Security (DOE/NN). IVSEM is a simple, top-level, modeling tool which estimates the performance of a Comprehensive Nuclear Test Ban Treaty (CTBT) monitoring system and can help explore the impact of various sensor system concepts and technology advancements on CTBT monitoring. One of IVSEM`s unique features is that it integrates results from the various CTBT sensor technologies (seismic, infrasound, radionuclide, and hydroacoustic) and allows the user to investigate synergy among the technologies. Specifically, IVSEM estimates the detection effectiveness (probability of detection) and location accuracy of the integrated system and of each technology subsystem individually. The model attempts to accurately estimate the monitoring system`s performance at medium interfaces (air-land, air-water) and for some evasive testing methods such as seismic decoupling. This report describes version 1.2 of IVSEM.

  18. Towards automatic verification of ladder logic programs

    OpenAIRE

    Zoubek , Bohumir; Roussel , Jean-Marc; Kwiatkowska , Martha

    2003-01-01

    International audience; Control system programs are usually validated by testing prior to their deployment. Unfortunately, testing is not exhaustive and therefore it is possible that a program which passed all the required tests still contains errors. In this paper we apply techniques of automatic verification to a control program written in ladder logic. A model is constructed mechanically from the ladder logic program and subjected to automatic verification against requirements that include...

  19. Fingerprint verification prediction model in hand dermatitis.

    Science.gov (United States)

    Lee, Chew K; Chang, Choong C; Johor, Asmah; Othman, Puwira; Baba, Roshidah

    2015-07-01

    Hand dermatitis associated fingerprint changes is a significant problem and affects fingerprint verification processes. This study was done to develop a clinically useful prediction model for fingerprint verification in patients with hand dermatitis. A case-control study involving 100 patients with hand dermatitis. All patients verified their thumbprints against their identity card. Registered fingerprints were randomized into a model derivation and model validation group. Predictive model was derived using multiple logistic regression. Validation was done using the goodness-of-fit test. The fingerprint verification prediction model consists of a major criterion (fingerprint dystrophy area of ≥ 25%) and two minor criteria (long horizontal lines and long vertical lines). The presence of the major criterion predicts it will almost always fail verification, while presence of both minor criteria and presence of one minor criterion predict high and low risk of fingerprint verification failure, respectively. When none of the criteria are met, the fingerprint almost always passes the verification. The area under the receiver operating characteristic curve was 0.937, and the goodness-of-fit test showed agreement between the observed and expected number (P = 0.26). The derived fingerprint verification failure prediction model is validated and highly discriminatory in predicting risk of fingerprint verification in patients with hand dermatitis. © 2014 The International Society of Dermatology.

  20. Verification of piping response calculations of SMACS code with data from seismic testing of an in-plant piping system

    International Nuclear Information System (INIS)

    Srinivasan, M.G.; Kot, C.A.; Hsieh, B.J.

    1991-09-01

    The objective of this effort was to evaluate the piping analysis part of the SMACS code for estimating the response of realistic piping systems subjected to seismic excitation, given as multiple, independent support acceleration histories. The experimental data from the seismic testing of an in-plant piping system at the HDR Test Facility in Germany were used for this purpose. Of the six different support systems tested, two were selected for the evaluation: one a ''stiff'' configuration containing both struts and snubbers, and the other, a more flexible configuration with no snubbers. Described are the analytical modeling, calculations, and results of the posttest simulation of two sets each for both support configurations, with excitations at 100% and 200/300% of safe-shutdown-earthquake loading. Almost all the calculated peak response quantities were smaller (by different amounts) than the corresponding test measurements. However, pipe displacements and bending stresses were better estimated than the pipe accelerations and support forces. The discrepancies are mainly attributable to the inability of the linear analysis to model the nonlinear behavior of the VKL piping system, characterized by gaps in support connections and the friction at pipe clamps. A similar trend of underestimating test responses was observed in the linear analyses performed by other investigators. 13 refs., 14 figs., 8 tabs

  1. Verification of the both hydrogeological and hydrogeochemical code results by an on-site test in granitic rocks

    Directory of Open Access Journals (Sweden)

    Michal Polák

    2007-01-01

    Full Text Available The project entitled “Methods and tools for the evaluation of the effect of engeneered barriers on distant interactions in the environment of a deep repository facility” deals with the ability to validate the behavior of applied engeneered barriers on hydrodynamic and migration parameters in the water-bearing granite environment of a radioactive waste deep repository facility. A part of the project represents a detailed mapping of the fracture network by means of geophysical and drilling surveys on the test-site (active granite quarry, construction of model objects (about 100 samples with the shape of cylinders, ridges and blocks, and the mineralogical, petrological and geochemical description of granite. All the model objects were subjected to migration and hydrodynamic tests with the use of fluorescein and NaCl as tracers. The tests were performed on samples with simple fractures, injected fractures and with an undisturbed integrity (verified by ultrasonic. The gained hydrodynamic and migration parameters of the model objects were processed with the modeling software NAPSAC and FEFLOW. During the following two years, these results and parameters will be verified (on the test-site by means of a long-term field test including the tuning of the software functionality.

  2. Modeling in the State Flow Environment to Support Launch Vehicle Verification Testing for Mission and Fault Management Algorithms in the NASA Space Launch System

    Science.gov (United States)

    Trevino, Luis; Berg, Peter; England, Dwight; Johnson, Stephen B.

    2016-01-01

    Analysis methods and testing processes are essential activities in the engineering development and verification of the National Aeronautics and Space Administration's (NASA) new Space Launch System (SLS). Central to mission success is reliable verification of the Mission and Fault Management (M&FM) algorithms for the SLS launch vehicle (LV) flight software. This is particularly difficult because M&FM algorithms integrate and operate LV subsystems, which consist of diverse forms of hardware and software themselves, with equally diverse integration from the engineering disciplines of LV subsystems. M&FM operation of SLS requires a changing mix of LV automation. During pre-launch the LV is primarily operated by the Kennedy Space Center (KSC) Ground Systems Development and Operations (GSDO) organization with some LV automation of time-critical functions, and much more autonomous LV operations during ascent that have crucial interactions with the Orion crew capsule, its astronauts, and with mission controllers at the Johnson Space Center. M&FM algorithms must perform all nominal mission commanding via the flight computer to control LV states from pre-launch through disposal and also address failure conditions by initiating autonomous or commanded aborts (crew capsule escape from the failing LV), redundancy management of failing subsystems and components, and safing actions to reduce or prevent threats to ground systems and crew. To address the criticality of the verification testing of these algorithms, the NASA M&FM team has utilized the State Flow environment6 (SFE) with its existing Vehicle Management End-to-End Testbed (VMET) platform which also hosts vendor-supplied physics-based LV subsystem models. The human-derived M&FM algorithms are designed and vetted in Integrated Development Teams composed of design and development disciplines such as Systems Engineering, Flight Software (FSW), Safety and Mission Assurance (S&MA) and major subsystems and vehicle elements

  3. Model tests of a once-through steam generator for land-blocker assessment and THEDA code verification. Final report

    International Nuclear Information System (INIS)

    Carter, H.R.; Childerson, M.T.; Moskal, T.E.

    1983-06-01

    The Babcock and Wilcox Company (B and W) operating Once-Through Steam Generators (OTSGs) have experienced leaking tubes in a region adjacent to the untubed inspection lane. The tube leaks have been attributed to an environmentally-assisted fatigue mechanism with moisture transported up the inspection lane being a major factor in the tube-failure process. B and W has developed a hardware modification (lane blockers) to mitigate the detrimental effects of inspection lane moisture. A 30-tube Laboratory Once-through Steam Generator (Designated OTSGC) was designed, fabricated, and tested. Tests were performed with and without five flat-plate lane blockers installed on tube-support plates (TSPs) 10, 11, 12, 13, and 14. The test results were utilized to determine the effectiveness of lane blockers for eliminating moisture transport to the upper tubesheet in the inspection lanes and to benchmark the predictive capabilities of a three-dimensional steam-generator computer code, THEDA

  4. Interim Letter Report - Verification Survey Results for Activities Performed in March 2009 for the Vitrification Test Facility Warehouse at the West Valley Demonstration Project, Ashford, New York

    Energy Technology Data Exchange (ETDEWEB)

    B.D. Estes

    2009-04-24

    The objective of the verification activities was to provide independent radiological surveys and data for use by the Department of Energy (DOE) to ensure that the building satisfies the requirements for release without radiological controls.

  5. SU-F-T-364: Monte Carlo-Dose Verification of Volumetric Modulated Arc Therapy Plans Using AAPM TG-119 Test Patterns

    International Nuclear Information System (INIS)

    Onizuka, R; Araki, F; Ohno, T; Nakaguchi, Y

    2016-01-01

    Purpose: To investigate the Monte Carlo (MC)-based dose verification for VMAT plans by a treatment planning system (TPS). Methods: The AAPM TG-119 test structure set was used for VMAT plans by the Pinnacle3 (convolution/superposition), using a Synergy radiation head of a 6 MV beam with the Agility MLC. The Synergy was simulated with the EGSnrc/BEAMnrc code, and VMAT dose distributions were calculated with the EGSnrc/DOSXYZnrc code by the same irradiation conditions as TPS. VMAT dose distributions of TPS and MC were compared with those of EBT3 film, by 2-D gamma analysis of ±3%/3 mm criteria with a threshold of 30% of prescribed doses. VMAT dose distributions between TPS and MC were also compared by DVHs and 3-D gamma analysis of ±3%/3 mm criteria with a threshold of 10%, and 3-D passing rates for PTVs and OARs were analyzed. Results: TPS dose distributions differed from those of film, especially for Head & neck. The dose difference between TPS and film results from calculation accuracy for complex motion of MLCs like tongue and groove effect. In contrast, MC dose distributions were in good agreement with those of film. This is because MC can model fully the MLC configuration and accurately reproduce the MLC motion between control points in VMAT plans. D95 of PTV for Prostate, Head & neck, C-shaped, and Multi Target was 97.2%, 98.1%, 101.6%, and 99.7% for TPS and 95.7%, 96.0%, 100.6%, and 99.1% for MC, respectively. Similarly, 3-D gamma passing rates of each PTV for TPS vs. MC were 100%, 89.5%, 99.7%, and 100%, respectively. 3-D passing rates of TPS reduced for complex VMAT fields like Head & neck because MLCs are not modeled completely for TPS. Conclusion: MC-calculated VMAT dose distributions is useful for the 3-D dose verification of VMAT plans by TPS.

  6. SU-F-T-364: Monte Carlo-Dose Verification of Volumetric Modulated Arc Therapy Plans Using AAPM TG-119 Test Patterns

    Energy Technology Data Exchange (ETDEWEB)

    Onizuka, R [Graduate School of Health Sciences, Kumamoto University (Japan); Araki, F; Ohno, T [Faculty of Life Sciences, Kumamoto University (Japan); Nakaguchi, Y [Kumamoto University Hospital (Japan)

    2016-06-15

    Purpose: To investigate the Monte Carlo (MC)-based dose verification for VMAT plans by a treatment planning system (TPS). Methods: The AAPM TG-119 test structure set was used for VMAT plans by the Pinnacle3 (convolution/superposition), using a Synergy radiation head of a 6 MV beam with the Agility MLC. The Synergy was simulated with the EGSnrc/BEAMnrc code, and VMAT dose distributions were calculated with the EGSnrc/DOSXYZnrc code by the same irradiation conditions as TPS. VMAT dose distributions of TPS and MC were compared with those of EBT3 film, by 2-D gamma analysis of ±3%/3 mm criteria with a threshold of 30% of prescribed doses. VMAT dose distributions between TPS and MC were also compared by DVHs and 3-D gamma analysis of ±3%/3 mm criteria with a threshold of 10%, and 3-D passing rates for PTVs and OARs were analyzed. Results: TPS dose distributions differed from those of film, especially for Head & neck. The dose difference between TPS and film results from calculation accuracy for complex motion of MLCs like tongue and groove effect. In contrast, MC dose distributions were in good agreement with those of film. This is because MC can model fully the MLC configuration and accurately reproduce the MLC motion between control points in VMAT plans. D95 of PTV for Prostate, Head & neck, C-shaped, and Multi Target was 97.2%, 98.1%, 101.6%, and 99.7% for TPS and 95.7%, 96.0%, 100.6%, and 99.1% for MC, respectively. Similarly, 3-D gamma passing rates of each PTV for TPS vs. MC were 100%, 89.5%, 99.7%, and 100%, respectively. 3-D passing rates of TPS reduced for complex VMAT fields like Head & neck because MLCs are not modeled completely for TPS. Conclusion: MC-calculated VMAT dose distributions is useful for the 3-D dose verification of VMAT plans by TPS.

  7. Blanket Manufacturing Technologies : Thermomechanical Tests on HCLL Blanket Mocks Up

    International Nuclear Information System (INIS)

    Laffont, G.; Cachon, L.; Taraud, P.; Challet, F.; Rampal, G.; Salavy, J.F.

    2006-01-01

    In the Helium Cooled Lithium Lead (HCLL) Blanket concept, the lithium lead plays the double role of breeder and multiplier material, and the helium is used as coolant. The HCCL Blanket Module are made of steel boxes reinforced by stiffening plates. These stiffening plates form cells in which the breeder is slowly flowing. The power deposited in the breeder material is recovered by the breeder cooling units constituted by 5 parallel cooling plates. All the structures such as first wall, stiffening and cooling plates are cooled by helium. Due to the complex geometry of these parts and the high level of pressure and temperature loading, thermo-mechanical phenomena expected in the '' HCLL blanket concept '' have motivated the present study. The aim of this study, carried out in the frame of EFDA Work program, is to validate the manufacturing technologies of HCLL blanket module by testing small scale mock-up under breeder blanket representative operating conditions.The first step of this experimental program is the design and manufacturing of a relevant test section in the DIADEMO facility, which was recently upgraded with an He cooling loop (pressure of 80 bar, maximum temperature of 500 o C,flow rate of 30 g/s) taking the opportunity of synergies with the gas-cooled fission reactor R-and-D program. The second step will deal with the thermo-mechanical tests. This paper focuses on the program made to support the cooling plate mock up tests which will be carried out on the DIADEMO facility (CEA) by thermo-mechanical calculations in order to define the relevant test conditions and the experimental parameters to be monitored. (author)

  8. Proceedings of the 22nd Annual DoD/DOE Seismic Research Symposium: Planning for Verification of and Compliance with the Comprehensive Nuclear-Test-Ban Treaty (CTBT)

    Energy Technology Data Exchange (ETDEWEB)

    Nichols, James W., LTC [Editor

    2000-09-15

    These proceedings contain papers prepared for the 22nd Annual DoD/DOE Seismic Research Symposium: Planning for Verification of and Compliance with the Comprehensive Nuclear-Test-Ban Treaty (CTBT), held 13-15 September 2000 in New Orleans, Louisiana. These papers represent the combined research related to ground-based nuclear explosion monitoring funded by the National Nuclear Security Administration (NNSA), Defense Threat Reduction Agency (DTRA), Air Force Technical Applications Center (AFTAC), Department of Defense (DoD), US Army Space and Missile Defense Command, Defense Special Weapons Agency (DSWA), and other invited sponsors. The scientific objectives of the research are to improve the United States capability to detect, locate, and identify nuclear explosions. The purpose of the meeting is to provide the sponsoring agencies, as well as potential users, an opportunity to review research accomplished during the preceding year and to discuss areas of investigation for the coming year. For the researchers, it provides a forum for the exchange of scientific information toward achieving program goals, and an opportunity to discuss results and future plans. Paper topics include: seismic regionalization and calibration; detection and location of sources; wave propagation from source to receiver; the nature of seismic sources, including mining practices; hydroacoustic, infrasound, and radionuclide methods; on-site inspection; and data processing.

  9. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Performance Verification Report: Initial Comprehensive Performance Test Report, P/N 1331200-2-IT, S/N 105/A2

    Science.gov (United States)

    Platt, R.

    1999-01-01

    This is the Performance Verification Report, Initial Comprehensive Performance Test Report, P/N 1331200-2-IT, S/N 105/A2, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A). The specification establishes the requirements for the Comprehensive Performance Test (CPT) and Limited Performance Test (LPT) of the Advanced Microwave Sounding, Unit-A2 (AMSU-A2), referred to herein as the unit. The unit is defined on Drawing 1331200. 1.2 Test procedure sequence. The sequence in which the several phases of this test procedure shall take place is shown in Figure 1, but the sequence can be in any order.

  10. Innovative Networking Concepts Tested on the Advanced Communications Technology Satellite

    Science.gov (United States)

    Friedman, Daniel; Gupta, Sonjai; Zhang, Chuanguo; Ephremides, Anthony

    1996-01-01

    This paper describes a program of experiments conducted over the advanced communications technology satellite (ACTS) and the associated TI-VSAT (very small aperture terminal). The experiments were motivated by the commercial potential of low-cost receive only satellite terminals that can operate in a hybrid network environment, and by the desire to demonstrate frame relay technology over satellite networks. The first experiment tested highly adaptive methods of satellite bandwidth allocation in an integrated voice-data service environment. The second involved comparison of forward error correction (FEC) and automatic repeat request (ARQ) methods of error control for satellite communication with emphasis on the advantage that a hybrid architecture provides, especially in the case of multicasts. Finally, the third experiment demonstrated hybrid access to databases and compared the performance of internetworking protocols for interconnecting local area networks (LANs) via satellite. A custom unit termed frame relay access switch (FRACS) was developed by COMSAT Laboratories for these experiments; the preparation and conduct of these experiments involved a total of 20 people from the University of Maryland, the University of Colorado and COMSAT Laboratories, from late 1992 until 1995.

  11. Application of high precision temperature control technology in infrared testing

    Science.gov (United States)

    Cao, Haiyuan; Cheng, Yong; Zhu, Mengzhen; Chu, Hua; Li, Wei

    2017-11-01

    In allusion to the demand of infrared system test, the principle of Infrared target simulator and the function of the temperature control are presented. The key technology of High precision temperature control is discussed, which include temperature gathering, PID control and power drive. The design scheme of temperature gathering is put forward. In order to reduce the measure error, discontinuously current and four-wire connection for the platinum thermal resistance are adopted. A 24-bits AD chip is used to improve the acquisition precision. Fuzzy PID controller is designed because of the large time constant and continuous disturbance of the environment temperature, which result in little overshoot, rapid response, high steady-state accuracy. Double power operational amplifiers are used to drive the TEC. Experiments show that the key performances such as temperature control precision and response speed meet the requirements.

  12. Current status of small specimen technology in Charpy impact testing

    International Nuclear Information System (INIS)

    Kurishita, H.; Kayano, H.; Narui, M.; Yamazaki, M.

    1994-01-01

    The current status of small-scale specimen technology in Charpy impact testing for ferritic steels is presented, with emphasis on the effect of the notch dimensions (notch depth, notch root radius and notch angle) on the upper shelf energy (USE) and ductile-to-brittle transition temperature (DBTT). The USE for miniaturized specimens, normalized by Bb 2 or (Bb) 3/2 (B is the specimen thickness, b the ligament size), is essentially independent of notch geometry and has a linear relationship with the USE of full size specimens, regardless of irradiation and alloy conditions. The DBTT of miniaturized specimens depends strongly on the notch dimensions; this dependence of the DBTT decreases as the DBTT of full size specimens increase due to neutron irradiation or thermal aging. These results may be useful in determining the USE and DBTT for full size specimens from those for miniaturized specimens. ((orig.))

  13. Verification and the safeguards legacy

    International Nuclear Information System (INIS)

    Perricos, Demetrius

    2001-01-01

    A number of inspection or monitoring systems throughout the world over the last decades have been structured drawing upon the IAEA experience of setting up and operating its safeguards system. The first global verification system was born with the creation of the IAEA safeguards system, about 35 years ago. With the conclusion of the NPT in 1968, inspections were to be performed under safeguards agreements, concluded directly between the IAEA and non-nuclear weapon states parties to the Treaty. The IAEA developed the safeguards system within the limitations reflected in the Blue Book (INFCIRC 153), such as limitations of routine access by the inspectors to 'strategic points', including 'key measurement points', and the focusing of verification on declared nuclear material in declared installations. The system, based as it was on nuclear material accountancy. It was expected to detect a diversion of nuclear material with a high probability and within a given time and therefore determine also that there had been no diversion of nuclear material from peaceful purposes. The most vital element of any verification system is the inspector. Technology can assist but cannot replace the inspector in the field. Their experience, knowledge, intuition and initiative are invaluable factors contributing to the success of any inspection regime. The IAEA inspectors are however not part of an international police force that will intervene to prevent a violation taking place. To be credible they should be technically qualified with substantial experience in industry or in research and development before they are recruited. An extensive training program has to make sure that the inspectors retain their professional capabilities and that it provides them with new skills. Over the years, the inspectors and through them the safeguards verification system gained experience in: organization and management of large teams; examination of records and evaluation of material balances

  14. Atmospheric transport modelling related to radionuclide monitoring in support of the comprehensive nuclear-test-ban treaty verification

    International Nuclear Information System (INIS)

    Kalinowski, M.B.

    2001-01-01

    Global monitoring for relevant radionuclides in the atmosphere serves as part of the International Monitoring System to verify compliance with the Comprehensive Nuclear-Test-Ban-Treaty (CTBT). Atmospheric transport modelling can be applied to support these measurements and to get indications for possible source locations of detected relevant anthropogenic nuclides. This paper puts a focus on those issues that are of relevance to the International Data Centre (IDC). Possible methods of atmospheric transport modelling are outlined. The current tentative implementation at the IDC is described here. (orig.) [de

  15. Verification and Performance Analysis for Embedded Systems

    DEFF Research Database (Denmark)

    Larsen, Kim Guldstrand

    2009-01-01

    This talk provides a thorough tutorial of the UPPAAL tool suite for, modeling, simulation, verification, optimal scheduling, synthesis, testing and performance analysis of embedded and real-time systems....

  16. Z-2 Architecture Description and Requirements Verification Results

    Science.gov (United States)

    Graziosi, Dave; Jones, Bobby; Ferl, Jinny; Scarborough, Steve; Hewes, Linda; Ross, Amy; Rhodes, Richard

    2016-01-01

    The Z-2 Prototype Planetary Extravehicular Space Suit Assembly is a continuation of NASA's Z series of spacesuits. The Z-2 is another step in NASA's technology development roadmap leading to human exploration of the Martian surface. The suit was designed for maximum mobility at 8.3 psid, reduced mass, and to have high fidelity life support interfaces. As Z-2 will be man-tested at full vacuum in NASA JSC's Chamber B, it was manufactured as Class II, making it the most flight-like planetary walking suit produced to date. The Z-2 suit architecture is an evolution of previous EVA suits, namely the ISS EMU, Mark III, Rear Entry I-Suit and Z-1 spacesuits. The suit is a hybrid hard and soft multi-bearing, rear entry spacesuit. The hard upper torso (HUT) is an all-composite structure and includes a 2-bearing rolling convolute shoulder with Vernier sizing mechanism, removable suit port interface plate (SIP), elliptical hemispherical helmet and self-don/doff shoulder harness. The hatch is a hybrid aluminum and composite construction with Apollo style gas connectors, custom water pass-thru, removable hatch cage and interfaces to primary and auxiliary life support feed water bags. The suit includes Z-1 style lower arms with cam brackets for Vernier sizing and government furnished equipment (GFE) Phase VI gloves. The lower torso includes a telescopic waist sizing system, waist bearing, rolling convolute waist joint, hard brief, 2 bearing soft hip thigh, Z-1 style legs with ISS EMU style cam brackets for sizing, and conformal walking boots with ankle bearings. The Z-2 Requirements Verification Plan includes the verification of more than 200 individual requirements. The verification methods include test, analysis, inspection, demonstration or a combination of methods. Examples of unmanned requirements include suit leakage, proof pressure testing, operational life, mass, isometric man-loads, sizing adjustment ranges, internal and external interfaces such as in-suit drink bag

  17. BIOMEX Experiment: Ultrastructural Alterations, Molecular Damage and Survival of the Fungus Cryomyces antarcticus after the Experiment Verification Tests

    Science.gov (United States)

    Pacelli, Claudia; Selbmann, Laura; Zucconi, Laura; De Vera, Jean-Pierre; Rabbow, Elke; Horneck, Gerda; de la Torre, Rosa; Onofri, Silvano

    2017-06-01

    The search for traces of extinct or extant life in extraterrestrial environments is one of the main goals for astrobiologists; due to their ability to withstand stress producing conditions, extremophiles are perfect candidates for astrobiological studies. The BIOMEX project aims to test the ability of biomolecules and cell components to preserve their stability under space and Mars-like conditions, while at the same time investigating the survival capability of microorganisms. The experiment has been launched into space and is being exposed on the EXPOSE-R2 payload, outside of the International Space Station (ISS) over a time-span of 1.5 years. Along with a number of other extremophilic microorganisms, the Antarctic cryptoendolithic black fungus Cryomyces antarcticus CCFEE 515 has been included in the experiment. Before launch, dried colonies grown on Lunar and Martian regolith analogues were exposed to vacuum, irradiation and temperature cycles in ground based experiments (EVT1 and EVT2). Cultural and molecular tests revealed that the fungus survived on rock analogues under space and simulated Martian conditions, showing only slight ultra-structural and molecular damage.

  18. Outlines and verifications of the codes used in the safety analysis of High Temperature Engineering Test Reactor (HTTR)

    International Nuclear Information System (INIS)

    Shiina, Yasuaki; Kunitomi, Kazuhiko; Maruyama, Soh; Fujita, Shigeki; Nakagawa, Shigeaki; Iyoku, Tatsuo; Shindoh, Masami; Sudo, Yukio; Hirano, Masashi.

    1990-03-01

    This paper presents brief description of the computer codes used in the safety analysis of High Temperature Engineering Test Reactor. The list of the codes is: 1. BLOOST-J2 2. THYDE-HTGR 3. TAC-NC 4. RATSAM6 5. COMPARE-MOD1 6. GRACE 7. OXIDE-3F 8. FLOWNET/TRUMP. Of described above, 1, 3, 4, 5, 6 and 7 were developed for the multi-hole type gas cooled reactor and improved for HTTR and 2 was originated by THYDE-codes which were developed to treat the transient thermo-hydraulics during LOCA of LWR. Each code adopted the models and properties which yield conservative analytical results. Adequacy of each code was verified by the comparison with the experimental results and/or the analytical results obtained from the other codes which were already proven. (author)

  19. Design of a Kaplan turbine for a wide range of operating head -Curved draft tube design and model test verification-

    Science.gov (United States)

    KO, Pohan; MATSUMOTO, Kiyoshi; OHTAKE, Norio; DING, Hua

    2016-11-01

    As for turbomachine off-design performance improvement is challenging but critical for maximising the performing area. In this paper, a curved draft tube for a medium head Kaplan type hydro turbine is introduced and discussed for its significant effect on expanding operating head range. Without adding any extra structure and working fluid for swirl destruction and damping, a carefully designed outline shape of draft tube with the selected placement of center-piers successfully supresses the growth of turbulence eddy and the transport of the swirl to the outlet. Also, more kinetic energy is recovered and the head lost is improved. Finally, the model test results are also presented. The obvious performance improvement was found in the lower net head area, where the maximum efficiency improvement was measured up to 20% without compromising the best efficiency point. Additionally, this design results in a new draft tube more compact in size and so leads to better construction and manufacturing cost performance for prototype. The draft tube geometry parameter designing process was concerning the best efficiency point together with the off-design points covering various water net heads and discharges. The hydraulic performance and flow behavior was numerically previewed and visualized by solving Reynolds-Averaged Navier-Stokes equations with Shear Stress Transport turbulence model. The simulation was under the assumption of steady-state incompressible turbulence flow inside the flow passage, and the inlet boundary condition was the carefully simulated flow pattern from the runner outlet. For confirmation, the corresponding turbine efficiency performance of the entire operating area was verified by model test.

  20. Initial ACTR retrieval technology evaluation test material recommendations

    International Nuclear Information System (INIS)

    Powell, M.R.

    1996-04-01

    Millions of gallons of radiaoctive waste are contained in underground storage tanks at Hanford (SE Washington). Techniques for retrieving much of this waste from the storage tanks have been developed. Current baseline approach is to use sluice jets for single-shell tanks and mixer pumps for double-shell tanks. The Acquire Commercial Technology for Retrieval (ACTR) effort was initiated to identify potential improvements in or alternatives to the baseline waste retrieval methods. Communications with a variety of vendors are underway to identify improved methods that can be implemented at Hanford with little or no additional development. Commercially available retrieval methods will be evaluated by a combination of testing and system-level cost estimation. Current progress toward developing waste simulants for testing ACTR candidate methods is reported; the simulants are designed to model 4 different types of tank waste. Simulant recipes are given for wet sludge, hardpan/dried sludge,hard saltcake, and soft saltcake. Comparisons of the waste and simulant properties are documented in this report