WorldWideScience

Sample records for technology verification tests

  1. VERIFICATION TESTING OF AIR POLLUTION CONTROL TECHNOLOGY QUALITY MANAGEMENT PLAN

    Science.gov (United States)

    This document is the basis for quality assurance for the Air Pollution Control Technology Verification Center (APCT Center) operated under the U.S. Environmental Protection Agency (EPA). It describes the policies, organizational structure, responsibilities, procedures, and qualit...

  2. ENVIRONMENTAL TECHNOLOGY VERIFICATION: TEST/QA PLAN FOR THE VERIFICATION TESTING OF SELECTIVE CATALYTIC REDUCTION CONTROL TECHNOLOGIES FOR HIGHWAY, NONROAD, AND STATIONARY USE DIESEL ENGINES

    Science.gov (United States)

    The U.S. Environmental Protection Agency established the Environmental Technology Verification Program to accelerate the development and commercialization of improved environmental technology through third party verification and reporting of product performance. Research Triangl...

  3. Verification Testing of Air Pollution Control Technology Quality Management Plan Revision 2.3

    Science.gov (United States)

    The Air Pollution Control Technology Verification Center was established in 1995 as part of the EPA’s Environmental Technology Verification Program to accelerate the development and commercialization of improved environmental technologies’ performance.

  4. TEST DESIGN FOR ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) OF ADD-ON NOX CONTROL UTILIZING OZONE INJECTION

    Science.gov (United States)

    The paper discusses the test design for environmental technology verification (ETV) of add-0n nitrogen oxides (NOx) control utilizing ozone injection. (NOTE: ETV is an EPA-established program to enhance domestic and international market acceptance of new or improved commercially...

  5. Environmental Technology Verification: Supplement to Test/QA Plan for Biological and Aerosol Testing of General Ventilation Air Cleaners; Bioaerosol Inactivation Efficiency by HVAC In-Duct Ultraviolet Light Air Cleaners

    Science.gov (United States)

    The Air Pollution Control Technology Verification Center has selected general ventilation air cleaners as a technology area. The Generic Verification Protocol for Biological and Aerosol Testing of General Ventilation Air Cleaners is on the Environmental Technology Verification we...

  6. Environmental technology verification methods

    CSIR Research Space (South Africa)

    Szewczuk, S

    2016-03-01

    Full Text Available Environmental Technology Verification (ETV) is a tool that has been developed in the United States of America, Europe and many other countries around the world to help innovative environmental technologies reach the market. Claims about...

  7. DOE/LLNL verification symposium on technologies for monitoring nuclear tests related to weapons proliferation

    International Nuclear Information System (INIS)

    Nakanishi, K.K.

    1993-01-01

    The rapidly changing world situation has raised concerns regarding the proliferation of nuclear weapons and the ability to monitor a possible clandestine nuclear testing program. To address these issues, Lawrence Livermore National Laboratory's (LLNL) Treaty Verification Program sponsored a symposium funded by the US Department of Energy's (DOE) Office of Arms Control, Division of Systems and Technology. The DOE/LLNL Symposium on Technologies for Monitoring Nuclear Tests Related to Weapons Proliferation was held at the DOE's Nevada Operations Office in Las Vegas, May 6--7,1992. This volume is a collection of several papers presented at the symposium. Several experts in monitoring technology presented invited talks assessing the status of monitoring technology with emphasis on the deficient areas requiring more attention in the future. In addition, several speakers discussed proliferation monitoring technologies being developed by the DOE's weapons laboratories

  8. Performance Testing of Homeland Security Technologies in U.S. EPA's Environmental Technology Verification (ETV) Program

    National Research Council Canada - National Science Library

    Kelly, Thomas J; Hofacre, Kent C; Derringer, Tricia L; Riggs, Karen B; Koglin, Eric N

    2004-01-01

    ... (reports and test plans available at www.epa.gov/etv). In the aftermath of the terrorist attacks of September 11, 2001, the ETV approach has also been employed in performance tests of technologies relevant to homeland security (HS...

  9. Development of the advanced PHWR technology -Verification tests for CANDU advanced fuel-

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Jang Hwan; Suk, Hoh Chun; Jung, Moon Kee; Oh, Duk Joo; Park, Joo Hwan; Shim, Kee Sub; Jang, Suk Kyoo; Jung, Heung Joon; Park, Jin Suk; Jung, Seung Hoh; Jun, Ji Soo; Lee, Yung Wook; Jung, Chang Joon; Byun, Taek Sang; Park, Kwang Suk; Kim, Bok Deuk; Min, Kyung Hoh [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-07-01

    This is the `94 annual report of the CANDU advanced fuel verification test project. This report describes the out-of pile hydraulic tests at CANDU-hot test loop for verification of CANFLEX fuel bundle. It is also describes the reactor thermal-hydraulic analysis for thermal margin and flow stability. The contents in this report are as follows; (1) Out-of pile hydraulic tests for verification of CANFLEX fuel bundle. (a) Pressure drop tests at reactor operation condition (b) Strength test during reload at static condition (c) Impact test during reload at impact load condition (d) Endurance test for verification of fuel integrity during life time (2) Reactor thermal-hydraulic analysis with CANFLEX fuel bundle. (a) Critical channel power sensitivity analysis (b) CANDU-6 channel flow analysis (c) Flow instability analysis. 61 figs, 29 tabs, 21 refs. (Author).

  10. Development of the advanced PHWR technology -Verification tests for CANDU advanced fuel-

    International Nuclear Information System (INIS)

    Jung, Jang Hwan; Suk, Hoh Chun; Jung, Moon Kee; Oh, Duk Joo; Park, Joo Hwan; Shim, Kee Sub; Jang, Suk Kyoo; Jung, Heung Joon; Park, Jin Suk; Jung, Seung Hoh; Jun, Ji Soo; Lee, Yung Wook; Jung, Chang Joon; Byun, Taek Sang; Park, Kwang Suk; Kim, Bok Deuk; Min, Kyung Hoh

    1995-07-01

    This is the '94 annual report of the CANDU advanced fuel verification test project. This report describes the out-of pile hydraulic tests at CANDU-hot test loop for verification of CANFLEX fuel bundle. It is also describes the reactor thermal-hydraulic analysis for thermal margin and flow stability. The contents in this report are as follows; (1) Out-of pile hydraulic tests for verification of CANFLEX fuel bundle. (a) Pressure drop tests at reactor operation condition (b) Strength test during reload at static condition (c) Impact test during reload at impact load condition (d) Endurance test for verification of fuel integrity during life time (2) Reactor thermal-hydraulic analysis with CANFLEX fuel bundle. (a) Critical channel power sensitivity analysis (b) CANDU-6 channel flow analysis (c) Flow instability analysis. 61 figs, 29 tabs, 21 refs. (Author)

  11. AN ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) PERFORMANCE TESTING OF THE INDUSTRIAL TEST SYSTEM, INC. CYANIDE REAGENTSTRIP™ TEST KIT

    Science.gov (United States)

    Cyanide can be present in various forms in water. The cyanide test kit evaluated in this verification study (Industrial Test System, Inc. Cyanide Regent Strip ™ Test Kit) was designed to detect free cyanide in water. This is done by converting cyanide in water to cyanogen...

  12. Development of Out-pile Test Technology for Fuel Assembly Performance Verification

    Energy Technology Data Exchange (ETDEWEB)

    Chun, Tae Hyun; In, W. K.; Oh, D. S. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)] (and others)

    2007-03-15

    Out-pile tests with full scale fuel assembly are to verify the design and to evaluate the performance of the final products. HTL for the hydraulic tests and FAMeCT for mechanical/structural tests were constructed in this project. The maximum operating conditions of HTL are 30 bar, 320 .deg. C, and 500 m3/hr. This facility can perform the pressure drop test, fuel assembly uplift test, and flow induced vibration test. FAMeCT can perform the bending and vibration tests. The verification of the developed facilities were carried out by comparing the reference data of the fuel assembly which was obtained at the Westinghouse Co. The compared data showed a good coincidence within uncertainties. FRETONUS was developed for high temperature and high pressure fretting wear simulator and performance test. A performance test was conducted for 500 hours to check the integrity, endurance, data acquisition capability of the simulator. The technology of turbulent flow analysis and finite element analysis by computation was developed. From the establishments of out-pile test facilities for full scale fuel assembly, the domestic infrastructure for PWR fuel development has been greatly upgraded.

  13. Nuclear test ban verification

    International Nuclear Information System (INIS)

    Chun, Kin-Yip

    1991-07-01

    This report describes verification and its rationale, the basic tasks of seismic verification, the physical basis for earthquake/explosion source discrimination and explosion yield determination, the technical problems pertaining to seismic monitoring of underground nuclear tests, the basic problem-solving strategy deployed by the forensic seismology resarch team at the University of Toronto, and the scientific significance of the team's research. The research carried out at the Univeristy of Toronto has two components: teleseismic verification using P wave recordings from the Yellowknife Seismic Array (YKA), and regional (close-in) verification using high-frequency L g and P n recordings from the Eastern Canada Telemetered Network. Major differences have been found in P was attenuation among the propagation paths connecting the YKA listening post with seven active nuclear explosion testing areas in the world. Significant revisions have been made to previously published P wave attenuation results, leading to more interpretable nuclear explosion source functions. (11 refs., 12 figs.)

  14. ENVIRONMENTAL TECHNOLOGY VERIFICATION, TEST REPORT OF CONTROL OF BIOAEROSOLS IN HVAC SYSTEMS, COLUMBUS INDUSTRIES HIGH EFFICIENCY MINI PLEAT

    Science.gov (United States)

    The U.S. Environmental Protection Agency (EPA) has created the Environmental Technology Verification (ETV) Program to facilitate the deployment of innovative or improved environmental technologies through performance verification and dissemination of information. The goal of the...

  15. Technology Foresight and nuclear test verification: a structured and participatory approach

    Science.gov (United States)

    Noack, Patrick; Gaya-Piqué, Luis; Haralabus, Georgios; Auer, Matthias; Jain, Amit; Grenard, Patrick

    2013-04-01

    As part of its mandate, the CTBTO's nuclear explosion monitoring programme aims to maintain its sustainability, effectiveness and its long-term relevance to the verification regime. As such, the PTS is conducting a Technology Foresight programme of activities to identify technologies, processes, concepts and ideas that may serve said purpose and become applicable within the next 20 years. Through the Technology Foresight activities (online conferences, interviews, surveys, workshops and other) we have involved the wider science community in the fields of seismology, infrasound, hydroacoustics, radionuclide technology, remote sensing and geophysical techniques. We have assembled a catalogue of over 200 items, which incorporate technologies, processes, concepts and ideas which will have direct future relevance to the IMS (International Monitoring System), IDC (International Data Centre) and OSI (On-Site Inspection) activities within the PTS. In order to render this catalogue as applicable and useful as possible for strategy and planning, we have devised a "taxonomy" based on seven categories, against which each technology is assessed through a peer-review mechanism. These categories are: 1. Focus area of the technology in question: identify whether the technology relates to (one or more of the following) improving our understanding of source and source physics; propagation modelling; data acquisition; data transport; data processing; broad modelling concepts; quality assurance and data storage. 2. Current Development Stage of the technology in question. Based on a scale from one to six, this measure is specific to PTS needs and broadly reflects Technology Readiness Levels (TRLs). 3. Impact of the technology on each of the following capabilities: detection, location, characterization, sustainment and confidence building. 4. Development cost: the anticipated monetary cost of validating a prototype (i.e. Development Stage 3) of the technology in question. 5. Time to

  16. CANDU RU fuel manufacturing basic technology development and advanced fuel verification tests

    International Nuclear Information System (INIS)

    Chung, Chang Hwan; Chang, S.K.; Hong, S.D.

    1999-04-01

    A PHWR advanced fuel named the CANFLEX fuel has been developed through a KAERI/AECL joint Program. The KAERI made fuel bundle was tested at the KAERI Hot Test Loop for the performance verification of the bundle design. The major test activities were the fuel bundle cross-flow test, the endurance fretting/vibration test, the freon CHF test, and the fuel bundle heat-up test. KAERI also has developing a more advanced PHWR fuel, the CANFLEX-RU fuel, using recovered uranium to extend fuel burn-up in the CANDU reactors. For the purpose of proving safety of the RU handling techniques and appraising feasibility of the CANFLEX-RU fuel fabrication in near future, a physical, chemical and radiological characterization of the RU powder and pellets was performed. (author). 54 refs., 46 tabs., 62 figs

  17. CANDU RU fuel manufacturing basic technology development and advanced fuel verification tests

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Chang Hwan; Chang, S.K.; Hong, S.D. [and others

    1999-04-01

    A PHWR advanced fuel named the CANFLEX fuel has been developed through a KAERI/AECL joint Program. The KAERI made fuel bundle was tested at the KAERI Hot Test Loop for the performance verification of the bundle design. The major test activities were the fuel bundle cross-flow test, the endurance fretting/vibration test, the freon CHF test, and the fuel bundle heat-up test. KAERI also has developing a more advanced PHWR fuel, the CANFLEX-RU fuel, using recovered uranium to extend fuel burn-up in the CANDU reactors. For the purpose of proving safety of the RU handling techniques and appraising feasibility of the CANFLEX-RU fuel fabrication in near future, a physical, chemical and radiological characterization of the RU powder and pellets was performed. (author). 54 refs., 46 tabs., 62 figs.

  18. Biometric Technologies and Verification Systems

    CERN Document Server

    Vacca, John R

    2007-01-01

    Biometric Technologies and Verification Systems is organized into nine parts composed of 30 chapters, including an extensive glossary of biometric terms and acronyms. It discusses the current state-of-the-art in biometric verification/authentication, identification and system design principles. It also provides a step-by-step discussion of how biometrics works; how biometric data in human beings can be collected and analyzed in a number of ways; how biometrics are currently being used as a method of personal identification in which people are recognized by their own unique corporal or behavior

  19. ENVIRONMENTAL TECHNOLOGY VERIFICATION, TEST REPORT OF CONTROL OF BIOAEROSOLS IN HVAC SYSTEMS, COLUMBUS INDUSTRIES SL-3 RING PANEL

    Science.gov (United States)

    The Environmental Technology Verification report discusses the technology and performance of the High Efficiency Mini Pleat air filter for dust and bioaerosol filtration manufactured by Columbus Industries. The pressure drop across the filter was 142 Pa clean and 283 Pa dust load...

  20. Verification of wet blasting decontamination technology

    International Nuclear Information System (INIS)

    Matsubara, Sachito; Murayama, Kazunari; Yoshida, Hirohisa; Igei, Shigemitsu; Izumida, Tatsuo

    2013-01-01

    Macoho Co., Ltd. participated in the projects of 'Decontamination Verification Test FY 2011 by the Ministry of the Environment' and 'Decontamination Verification Test FY 2011 by the Cabinet Office.' And we tested verification to use a wet blasting technology for decontamination of rubble and roads contaminated by the accident of Fukushima Daiichi Nuclear Power Plant of the Tokyo Electric Power Company. As a results of the verification test, the wet blasting decontamination technology showed that a decontamination rate became 60-80% for concrete paving, interlocking, dense-grated asphalt pavement when applied to the decontamination of the road. When it was applied to rubble decontamination, a decontamination rate was 50-60% for gravel and approximately 90% for concrete and wood. It was thought that Cs-134 and Cs-137 attached to the fine sludge scraped off from a decontamination object and the sludge was found to be separated from abrasives by wet cyclene classification: the activity concentration of the abrasives is 1/30 or less than the sludge. The result shows that the abrasives can be reused without problems when the wet blasting decontamination technology is used. (author)

  1. ENVIRONMENTAL TECHNOLOGY VERIFICATION--TEST REPORT OF MOBILE SOURCE EMISSION CONTROL DEVICES, FLINT HILLS RESOURCES, LP, CCD15010 DIESEL FUEL FORMULATION WITH HITEC4121 ADDITIVE

    Science.gov (United States)

    The U.S. Environmental Protection Agency (EPA) has created the Environmental Technology Verification (ETV) Program to facilitate the deployment of innovative or improved environmental technologies through performance verification and dissemination of information. ETV seeks to ach...

  2. INNOVATIVE TECHNOLOGY VERIFICATION REPORT " ...

    Science.gov (United States)

    The RemediAidTm Total Petroleum Hydrocarbon Starter Kit (RemediAidTm kit) developed by CHEMetries, Inc. (CHEMetrics), and AZUR Environmental Ltd was demonstrated under the U.S. Environmental Protection Agency Superfund Innovative Technology Evaluation Program in June 2000 at the Navy Base Ventura County site in Port Hueneme, California. The purpose of the demonstration was to collect reliable performance and cost data for the RemediAid Tm kit and six other field measurement devices for total petroleum hydrocarbons (TPH) in soil. In addition to assessing ease of device operation, the key objectives of the demonstration included determining the (1) method detection limit, (2) accuracy and precision, (3) effects of interferents and soil moisture content on TPH measurement, (4) sample throughput, and (5) TPH measurement costs for each device. The demonstration involved analysis of both performance evaluation samples and environmental samples collected in five areas contaminated with gasoline, diesel, lubricating oil, or other petroleum products. The performance and cost results for a given field measurement device were compared to those for an off-site laboratory reference method,

  3. ENVIRONMENTAL TECHNOLOGY VERIFICATION, TEST REPORT OF MOBILE SOURCE EMISSIONS CONTROL DEVICES/CLEAN DIESEL TECHNOLOGIES FUEL BORNE CATALYST WITH CLEANAIR SYSTEM'S DIESEL OXIDATION CATALYST

    Science.gov (United States)

    The Environmental Technology Verification report discusses the technology and performance of the Fuel-Borne Catalyst with CleanAir System's Diesel Oxidation Catalyst manufactured by Clean Diesel Technologies, Inc. The technology is a fuel-borne catalyst used in ultra low sulfur d...

  4. ENVIRONMENTAL TECHNOLOGY VERIFICATION, TEST REPORT OF MOBILE SOURCE EMISSIONS CONTROL DEVICES: CLEAN DIESEL TECHNOLOGIES FUEL-BORNE CATALYST WITH MITSUI/PUREARTH CATALYZED WIRE MESH FILTER

    Science.gov (United States)

    The Environmental Technology Verification report discusses the technology and performance of the Fuel-Borne Catalyst with Mitsui/PUREarth Catalyzed Wire Mesh Filter manufactured by Clean Diesel Technologies, Inc. The technology is a platinum/cerium fuel-borne catalyst in commerci...

  5. Environmental Technology Verification Report for Abraxis Ecologenia® 17β-Estradiol (E2) Microplate Enzyme-Linked Immunosorbent Assay (ELISA) Test Kits

    Science.gov (United States)

    This verification test was conducted according to procedures specifiedin the Test/QA Planfor Verification of Enzyme-Linked Immunosorbent Assay (ELISA) Test Kis for the Quantitative Determination of Endocrine Disrupting Compounds (EDCs) in Aqueous Phase Samples. Deviations to the...

  6. Verification of the machinery condition monitoring technology by fault simulation tests

    International Nuclear Information System (INIS)

    Maehara, Takafumi; Watanabe, Yukio; Osaki, Kenji; Higuma, Koji; Nakano, Tomohito

    2009-01-01

    This paper shows the test items and equipments introduced by Japan Nuclear Energy Safety Organization to establish the monitoring technique for machinery conditions. From the result of vertical pump simulation tests, it was confirmed that fault analysis was impossible by measuring the accelerations on both motor and pump column pipes, however, was possible by measuring of pump shaft vibrations. Because hydraulic whirls by bearing wear had significant influences over bearing misalignments and flow rates, the monitoring trends must be done under the same condition (on bearing alignments and flow rates). We have confirmed that malfunctions of vertical pumps can be diagnosed using measured shaft vibration by ultrasonic sensors from outer surface of pump casing on the floor. (author)

  7. Verification tests for CANDU advanced fuel -Development of the advanced CANDU technology-

    International Nuclear Information System (INIS)

    Chung, Jang Hwan; Suk, Ho Cheon; Jeong, Moon Ki; Park, Joo Hwan; Jeong, Heung Joon; Jeon, Ji Soo; Kim, Bok Deuk

    1994-07-01

    This project is underway in cooperation with AECL to develop the CANDU advanced fuel bundle (so-called, CANFLEX) which can enhance reactor safety and fuel economy in comparison with the current CANDU fuel and which can be used with natural uranium, slightly enriched uranium and other advanced fuel cycle. As the final schedule, the advanced fuel will be verified by carrying out a large scale demonstration of the bundle irradiation in a commercial CANDU reactor, and consequently will be used in the existing and future CANDU reactors in Korea. The research activities during this year Out-of-pile hydraulic tests for the prototype of CANFLEX bundle was conducted in the CANDU-hot test loop at KAERI. Thermalhydraulic analysis with the assumption of CANFLEX-NU fuel loaded in Wolsong-1 was performed by using thermalhydraulic code, and the thermal margin and T/H compatibility of CANFLEX bundle with existing fuel for CANDU-6 reactor have been evaluated. (Author)

  8. USE OF PERFLUOROCARBON TRACER (PFT) TECHNOLOGY FOR SUBSURFACE BARRIER INTEGRITY VERIFICATION AT THE WALDO TEST SITE

    Energy Technology Data Exchange (ETDEWEB)

    SULLIVAN,T.; HEISER,J.; SENUM,G.; MILLIAN,L.

    2000-02-27

    Researchers from Brookhaven National Laboratory (BNL) tested perfluorocarbon (PFT) gas tracers on a subsurface barrier with known flaws at the Waldo test facility [operated by Science and Engineering Associates, Inc (SEA)]. The tests involved the use of five unique PFT tracers with a different tracer injected along the interior of each wall of the barrier. A fifth tracer was injected exterior to the barrier to examine the validity of diffusion controlled transport of the PFTs. The PFTs were injected for three days at a nominal flow rate of 15 cm{sup 3}/min and a concentrations in the range of a few hundred ppm. Approximately 65 liters of air laced with tracer was injected for each tracer. The tracers were able to accurately detect the presence of the engineered flaws. Two flaws were detected on the north and east walls and lane flaw was detected on the south and west walls. In addition, one non-engineered flaw at the seam between the north and east walls was also detected. The use of multiple tracers provided independent confirmation of the flaws and permitted a distinction between tracers arriving at a monitoring port after being released from a nearby flaw and non-engineered flaws. The PFTs detected the smallest flaw, 0.5 inches in diameter. Visual inspection of the data showed excellent agreement with the known flaw locations and the relative size of the flaws was accurately estimated.

  9. The construction of environments for development of test and verification technology -The development of advanced instrumentation and control technology-

    International Nuclear Information System (INIS)

    Kwon, Kee Choon; Ham, Chang Shick; Lee, Byung Sun; Kim, Jung Taek; Park, Won Man; Park, Jae Chang; Kim, Jae Hee; Lee, Chang Soo

    1994-07-01

    Several problems were identified in digitalizing the I and C systems of NPPs. A scheme is divided into hardware and software to resolve these problems. Hardware verification and validation analyzed about common mode failure, commercial grade dedication process, electromagnetic competibility. We have reviewed codes and standards to be a consensus criteria among vendor, licenser. Then we have described the software licensing procedures under 10 CFR 50 and 10 CFR 52 in the United States Nuclear Regulatory Commision (NRC) and presented vendor's approaches to scope with the licensing barrier. At last, we have surveyed the technical issues related to developing and licensing the high integrity software for digital I and C systems. (Author)

  10. ENVIRONMENTAL TECHNOLOGY VERIFICATION--TEST REPORT OF MOBILE SOURCE EMISSION CONTROL DEVICES, CUMMINS EMISSION SOLUTIONS AND CUMMINS FILTRATION DIESEL OXIDATION CATALYST AND CLOSED CRANKCASE VENTILATION SYSTEM

    Science.gov (United States)

    The U.S. EPA has created the Environmental Technology Verification (ETV) Program. ETV seeks to provide high-quality, peer-reviewed data on technology performance. The Air Pollution Control Technology (APCT) Verification Center, a center under the ETV Program, is operated by Res...

  11. Testing and Demonstrating Speaker Verification Technology in Iraqi-Arabic as Part of the Iraqi Enrollment Via Voice Authentication Project (IEVAP) in Support of the Global War on Terrorism (GWOT)

    National Research Council Canada - National Science Library

    Withee, Jeffrey W; Pena, Edwin D

    2007-01-01

    This thesis documents the findings of an Iraqi-Arabic language test and concept of operations for speaker verification technology as part of the Iraqi Banking System in support of the Iraqi Enrollment...

  12. AN ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) TESTING OF THREE IMMUNOASSAY TEST KITS FOR ANTHRAX, BOTULINUM TOXIN AND RICIN

    Science.gov (United States)

    Immunoassay test kits are based on immunoassay methods, where specific antibodies are used to detect and measure the contaminants of interest. Immunoassay test kits rely on the reaction of a contaminant or antigen with a selective antibody to give a product that can be measures....

  13. AN ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) TESTING OF TWO HYDROGEN SULFIDE ANALYZERS: HORIBA INSTRUMENTS, INC., APSA-360 AND TELEDYNE-API MODEL 101E

    Science.gov (United States)

    The Environmental Technology Verification (ETV) Program, beginning as an initiative of the U.S. Environmental Protection Agency (EPA) in 1995, verifies the performance of commercially available, innovative technologies that can be used to measure environmental quality. The ETV p...

  14. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, GROUNDWATER SAMPLING TECHNOLOGIES, GEOPROBE INC., PNEUMATIC BLADDER PUMP GW 1400 SERIES

    Science.gov (United States)

    The U.S. Environmental Protection Agency (EPA) design efficient processes for conducting has created the Environmental Technology perfofl1lance tests of innovative technologies. Verification Program (E TV) to facilitate the deployment of innovative or improved environmental techn...

  15. VEG-01: Veggie Hardware Verification Testing

    Science.gov (United States)

    Massa, Gioia; Newsham, Gary; Hummerick, Mary; Morrow, Robert; Wheeler, Raymond

    2013-01-01

    The Veggie plant/vegetable production system is scheduled to fly on ISS at the end of2013. Since much of the technology associated with Veggie has not been previously tested in microgravity, a hardware validation flight was initiated. This test will allow data to be collected about Veggie hardware functionality on ISS, allow crew interactions to be vetted for future improvements, validate the ability of the hardware to grow and sustain plants, and collect data that will be helpful to future Veggie investigators as they develop their payloads. Additionally, food safety data on the lettuce plants grown will be collected to help support the development of a pathway for the crew to safely consume produce grown on orbit. Significant background research has been performed on the Veggie plant growth system, with early tests focusing on the development of the rooting pillow concept, and the selection of fertilizer, rooting medium and plant species. More recent testing has been conducted to integrate the pillow concept into the Veggie hardware and to ensure that adequate water is provided throughout the growth cycle. Seed sanitation protocols have been established for flight, and hardware sanitation between experiments has been studied. Methods for shipping and storage of rooting pillows and the development of crew procedures and crew training videos for plant activities on-orbit have been established. Science verification testing was conducted and lettuce plants were successfully grown in prototype Veggie hardware, microbial samples were taken, plant were harvested, frozen, stored and later analyzed for microbial growth, nutrients, and A TP levels. An additional verification test, prior to the final payload verification testing, is desired to demonstrate similar growth in the flight hardware and also to test a second set of pillows containing zinnia seeds. Issues with root mat water supply are being resolved, with final testing and flight scheduled for later in 2013.

  16. Test/QA Plan for Verification of Cavity Ringdown Spectroscopy Systems for Ammonia Monitoring in Stack Gas

    Science.gov (United States)

    The purpose of the cavity ringdown spectroscopy (CRDS) technology test and quality assurance plan is to specify procedures for a verification test applicable to commercial cavity ringdown spectroscopy technologies. The purpose of the verification test is to evaluate the performa...

  17. Decontamination technology verification test on scraping surface soil on the highway roadside slopes using unmanned scraping machine

    International Nuclear Information System (INIS)

    Fujinaka, Hiroyuki; Kubota, Mitsuru; Shibuya, Susumu; Kasai, Yoshimitsu

    2013-01-01

    The restore the normal life in the contaminated area, reconstruction of the infrastructure is necessary and early decontamination of roads and roadside slopes of highway are required. Decontamination work of roadside slopes is conducted only by hand working so far, but on the high and steep roadside slopes it is desirable to carry out decontamination work by an unmanned scraping machine to reduce working hours and improve safety. In this verification test, decontamination work of the roadside slope of highway, of which area was 20m W x 15m L and divided into two sections, was implemented by the machine or by hand, and working hours and radiation exposure dose were measured. As the results of the test, working hours and radiation exposure dose by the machine were 49% and 63% respectively compared to those by hand. Based on the results, cost and radiation dose for decontamination work on larger slopes were evaluated. Cost by the machine is estimated to be less than that by hand where the area is over 4,000m 2 . It is confirmed that the decontamination work of roadside slopes by the machine can be done more quickly and safely in comparison with hand working. (author)

  18. ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) PROGRAM: GREEN BUILDING TECHNOLOGIES

    Science.gov (United States)

    The U.S. Environmental Protection Agency (EPA) Environmental Technology Verification (ETV) Program evaluates the performance of innovative air, water, pollution prevention and monitoring technologies that have the potential to improve human health and the environment. This techno...

  19. Complementary technologies for verification of excess plutonium

    International Nuclear Information System (INIS)

    Langner, D.G.; Nicholas, N.J.; Ensslin, N.; Fearey, B.L.; Mitchell, D.J.; Marlow, K.W.; Luke, S.J.; Gosnell, T.B.

    1998-01-01

    Three complementary measurement technologies have been identified as candidates for use in the verification of excess plutonium of weapons origin. These technologies: high-resolution gamma-ray spectroscopy, neutron multiplicity counting, and low-resolution gamma-ray spectroscopy, are mature, robust technologies. The high-resolution gamma-ray system, Pu-600, uses the 630--670 keV region of the emitted gamma-ray spectrum to determine the ratio of 240 Pu to 239 Pu. It is useful in verifying the presence of plutonium and the presence of weapons-grade plutonium. Neutron multiplicity counting is well suited for verifying that the plutonium is of a safeguardable quantity and is weapons-quality material, as opposed to residue or waste. In addition, multiplicity counting can independently verify the presence of plutonium by virtue of a measured neutron self-multiplication and can detect the presence of non-plutonium neutron sources. The low-resolution gamma-ray spectroscopic technique is a template method that can provide continuity of knowledge that an item that enters the a verification regime remains under the regime. In the initial verification of an item, multiple regions of the measured low-resolution spectrum form a unique, gamma-radiation-based template for the item that can be used for comparison in subsequent verifications. In this paper the authors discuss these technologies as they relate to the different attributes that could be used in a verification regime

  20. ENVIRONMENTAL TECHNOLOGY VERIFICATION: TEST REPORT OF MOBILE SOURCE EMISSION CONTROL DEVICES--PUREM NORTH AMERICA LLC, PMF GREENTEC 1004205.00.0 DIESEL PARTICULATE FILTER

    Science.gov (United States)

    The U.S. EPA has created the Environmental Technology Verification (ETV) program to provide high quality, peer reviewed data on technology performance to those involved in the design, distribution, financing, permitting, purchase, and use of environmental technologies. The Air Po...

  1. ENVIRONMENTAL TECHNOLOGY VERIFICATION, TEST REPORT OF CONTROL OF BIOAEROSOLS IN HVAC SYSTEMS, FILTRATION GROUP, AEROSTAR FP-98 MINIPLEAT V-BLANK FILTER

    Science.gov (United States)

    The Environmental Technology Verification report discusses the technology and performance of the AeroStar FP-98 Minipleat V-Bank Filter air filter for dust and bioaerosol filtration manufactured by Filtration Group. The pressure drop across the filter was 137 Pa clean and 348 Pa ...

  2. ENVIRONMENTAL TECHNOLOGY VERIFICATION, TEST REPORT OF CONTROL OF BIOAEROSOLS IN HVAC SYSTEMS:AAF INTERNATIONAL, PERFECTPLEAT ULTRA, 175-102-863

    Science.gov (United States)

    The Environmental Technology Verification report discusses the technology and performance of the PerfectPleat Ultra 175-102-863 air filter for dust and bioaerosol filtration manufactured by AAF International. The pressure drop across the filter was 112 Pa clean and 229 Pa dust lo...

  3. Verification tests for CANDU advanced fuel

    International Nuclear Information System (INIS)

    Chung, Chang Hwan; Chang, S.K.; Hong, S.D.

    1997-07-01

    For the development of a CANDU advanced fuel, the CANFLEX-NU fuel bundles were tested under reactor operating conditions at the CANDU-Hot test loop. This report describes test results and test methods in the performance verification tests for the CANFLEX-NU bundle design. The main items described in the report are as follows. - Fuel bundle cross-flow test - Endurance fretting/vibration test - Freon CHF test - Production of technical document. (author). 25 refs., 45 tabs., 46 figs

  4. Technology for bolus verification in proton therapy

    Science.gov (United States)

    Shipulin, K. N.; Mytsin, G. V.; Agapov, A. V.

    2015-01-01

    To ensure the conformal depth-dose distribution of a proton beam within a target volume, complex shaped range shifters (so-called boluses), which account for the heterogeneous structure of patient tissue and organs in the beam path, were calculated and manufactured. The precise manufacturing of proton compensators used for patient treatment is a vital step in quality assurance in proton therapy. In this work a software-hardware complex that verifies the quality and precision of bolus manufacturing at the Medico-Technical Complex (MTC) was developed. The boluses consisted of a positioning system with two photoelectric biosensors. We evaluated 20 boluses used in proton therapy of five patients. A total number of 2562 experimental points were measured, of which only two points had values that differed from the calculated value by more than 0.5 mm. The other data points displayed a deviation within ±0.5 mm from the calculated value. The technology for bolus verification developed in this work can be used for the high precision testing of geometrical parameters of proton compensators in radiotherapy.

  5. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, REMOVAL OF ARSENIC IN DRINKING WATER: PHASE 1-ADI PILOT TEST UNIT NO. 2002-09 WITH MEDIA G2®

    Science.gov (United States)

    Integrity verification testing of the ADI International Inc. Pilot Test Unit No. 2002-09 with MEDIA G2® arsenic adsorption media filter system was conducted at the Hilltown Township Water and Sewer Authority (HTWSA) Well Station No. 1 in Sellersville, Pennsylvania from October 8...

  6. Standardized Definitions for Code Verification Test Problems

    Energy Technology Data Exchange (ETDEWEB)

    Doebling, Scott William [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-09-14

    This document contains standardized definitions for several commonly used code verification test problems. These definitions are intended to contain sufficient information to set up the test problem in a computational physics code. These definitions are intended to be used in conjunction with exact solutions to these problems generated using Exact- Pack, www.github.com/lanl/exactpack.

  7. Enhanced Verification Test Suite for Physics Simulation Codes

    Energy Technology Data Exchange (ETDEWEB)

    Kamm, J R; Brock, J S; Brandon, S T; Cotrell, D L; Johnson, B; Knupp, P; Rider, W; Trucano, T; Weirs, V G

    2008-10-10

    This document discusses problems with which to augment, in quantity and in quality, the existing tri-laboratory suite of verification problems used by Los Alamos National Laboratory (LANL), Lawrence Livermore National Laboratory (LLNL), and Sandia National Laboratories (SNL). The purpose of verification analysis is demonstrate whether the numerical results of the discretization algorithms in physics and engineering simulation codes provide correct solutions of the corresponding continuum equations. The key points of this document are: (1) Verification deals with mathematical correctness of the numerical algorithms in a code, while validation deals with physical correctness of a simulation in a regime of interest. This document is about verification. (2) The current seven-problem Tri-Laboratory Verification Test Suite, which has been used for approximately five years at the DOE WP laboratories, is limited. (3) Both the methodology for and technology used in verification analysis have evolved and been improved since the original test suite was proposed. (4) The proposed test problems are in three basic areas: (a) Hydrodynamics; (b) Transport processes; and (c) Dynamic strength-of-materials. (5) For several of the proposed problems we provide a 'strong sense verification benchmark', consisting of (i) a clear mathematical statement of the problem with sufficient information to run a computer simulation, (ii) an explanation of how the code result and benchmark solution are to be evaluated, and (iii) a description of the acceptance criterion for simulation code results. (6) It is proposed that the set of verification test problems with which any particular code be evaluated include some of the problems described in this document. Analysis of the proposed verification test problems constitutes part of a necessary--but not sufficient--step that builds confidence in physics and engineering simulation codes. More complicated test cases, including physics models of

  8. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, SHARPE MANUFACTURING TITANIUM T1-CG SPRAY GUN

    Science.gov (United States)

    Under EPA’s Environmental Technology Verification program, which provides objective and scientific third party analysis of new technology that can benefit the environment, the pollution prevention capabilities of a high transfer efficiency liquid spray gun was tested. This ...

  9. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, ANEST IWATA CORPORATION W400-LV SPRAY GUN

    Science.gov (United States)

    Under EPA’s Environmental Technology Verification program, which provides objective and scientific third party analysis of new technology that can benefit the environment, the pollution prevention capabilities of a high transfer efficiency liquid spray gun was tested. This ...

  10. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: BIOQUELL, INC. CLARIS C HYDROGEN PEROXIDE GAS GENERATOR

    Science.gov (United States)

    The Environmental Technology Verification report discusses the technology and performance of the Clarus C Hydrogen Peroxide Gas Generator, a biological decontamination device manufactured by BIOQUELL, Inc. The unit was tested by evaluating its ability to decontaminate seven types...

  11. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, REMOVAL OF ARSENIC IN DRINKING WATER: ADI INTERNATIONAL INC. ADI PILOT TEST UNIT NO. 2002-09 WITH MEDIA G2®; PHASE II

    Science.gov (United States)

    Verification testing of the ADI International Inc. Unit No. 2002-09 with MEDIA G2® arsenic adsorption media filter system was conducted at the Hilltown Township Water and Sewer Authority (HTWSA) Well Station No. 1 in Sellersville, Pennsylvania from October 8, 2003 through May 28,...

  12. PORFLOW TESTING AND VERIFICATION DOCUMENT

    International Nuclear Information System (INIS)

    Aleman, S

    2007-01-01

    The PORFLOW software package is a comprehensive mathematical model for simulation of multi-phase fluid flow, heat transfer and mass transport in variably saturated porous and fractured media. PORFLOW can simulate transient or steady-state problems in Cartesian or cylindrical geometry. The porous medium may be anisotropic and heterogeneous and may contain discrete fractures or boreholes with the porous matrix. The theoretical models within the code provide a unified treatment of concepts relevant to fluid flow and transport. The main features of PORFLOW that are relevant to Performance Assessment modeling at the Savannah River National Laboratory (SRNL) include variably saturated flow and transport of parent and progeny radionuclides. This document involves testing a relevant sample of problems in PORFLOW and comparing the outcome of the simulations to analytical solutions or other commercial codes. The testing consists of the following four groups. Group 1: Groundwater Flow; Group 2: Contaminant Transport; Group 3: Numerical Dispersion; and Group 4: Keyword Commands

  13. FLUENT Test and Verification Document

    International Nuclear Information System (INIS)

    LEE, SI

    2006-01-01

    The FLUENT 6 CFD code has been benchmarked for a wide range of simple, classical, and complex physical problems associated with turbulent gas flow, natural convection, and turbulent mixing phenomena. The results validate the application of previous scoping calculations for the Tank 50/Tank 48 vapor space mixing. The benchmarked problems consisted of three groups. The first group was well-defined and classical problems for which analytical solutions exist. The other groups are complex and physical problems for which analytical solutions are difficult to obtain. For these test problems, CFD results were compared and verified through comparisons with experimental results. The benchmarking of the FLUENT 6 code showed that the code predictions are in good agreement with the analytical solutions or experimental test data. The code was shown to be sufficiently accurate to make reliable decisions based on calculated results for those applications that fall within the scope of the benchmarking test cases. For applications that fall outside the range of the benchmarking results, particularly for significantly higher benzene concentrations or for flow geometries not adequately represented by the κ-(var e psilon) turbulence model, further benchmarking work would be required

  14. Advanced Technologies for Design Information Verification

    International Nuclear Information System (INIS)

    Watkins, Michael L.; Sheen, David M.; Rose, Joseph L.; Cumblidge, Stephen E.

    2009-01-01

    This paper discusses several technologies that have the potential to enhance facilities design verification. These approaches have shown promise in addressing the challenges associated with the verification of sub-component geometry and material composition for structures that are not directly accessible for physical inspection. A simple example is a pipe that extends into or through a wall or foundation. Both advanced electromagnetic and acoustic modalities will be discussed. These include advanced radar imaging, transient thermographic imaging, and guided acoustic wave imaging. Examples of current applications are provided. The basic principles and mechanisms of these inspection techniques are presented along with the salient practical features, advantages, and disadvantages of each technique. Other important considerations, such as component geometries, materials, and degree of access are also treated. The importance of, and strategies for, developing valid inspection models are also discussed. Beyond these basic technology adaptation and evaluation issues, important user interface considerations are outlined, along with approaches to quantify the overall performance reliability of the various inspection methods.

  15. Subsurface barrier verification technologies, informal report

    International Nuclear Information System (INIS)

    Heiser, J.H.

    1994-06-01

    One of the more promising remediation options available to the DOE waste management community is subsurface barriers. Some of the uses of subsurface barriers include surrounding and/or containing buried waste, as secondary confinement of underground storage tanks, to direct or contain subsurface contaminant plumes and to restrict remediation methods, such as vacuum extraction, to a limited area. To be most effective the barriers should be continuous and depending on use, have few or no breaches. A breach may be formed through numerous pathways including: discontinuous grout application, from joints between panels and from cracking due to grout curing or wet-dry cycling. The ability to verify barrier integrity is valuable to the DOE, EPA, and commercial sector and will be required to gain full public acceptance of subsurface barriers as either primary or secondary confinement at waste sites. It is recognized that no suitable method exists for the verification of an emplaced barrier's integrity. The large size and deep placement of subsurface barriers makes detection of leaks challenging. This becomes magnified if the permissible leakage from the site is low. Detection of small cracks (fractions of an inch) at depths of 100 feet or more has not been possible using existing surface geophysical techniques. Compounding the problem of locating flaws in a barrier is the fact that no placement technology can guarantee the completeness or integrity of the emplaced barrier. This report summarizes several commonly used or promising technologies that have been or may be applied to in-situ barrier continuity verification

  16. Natural gas production verification tests

    International Nuclear Information System (INIS)

    1992-02-01

    This Environmental Assessment (EA) has been prepared by the Department of Energy (DOE) in compliance with the requirements of the National Environmental Policy Act of 1969. The Department of Energy (DOE) proposes to fund, through a contract with Petroleum Consulting Services, Inc. of Canton, Ohio, the testing of the effectiveness of a non-water based hydraulic fracturing treatment to increase gas recovery from low-pressure, tight, fractured Devonian Shale formations. Although Devonian Shales are found in the Appalachian, Michigan, and Illinois Basins, testing will be done only in the dominant, historical five state area of established production. The objective of this proposed project is to assess the benefits of liquid carbon dioxide (CO 2 )/sand stimulations in the Devonian Shale. In addition, this project would evaluate the potential nondamaging (to the formation) properties of this unique fracturing treatment relative to the clogging or chocking of pores and fractures that act as gas flow paths to the wellbore in the target gas-producing zones of the formation. This liquid CO 2 /sand fracturing process is water-free and is expected to facilitate gas well cleanup, reduce the time required for post-stimulation cleanup, and result in improved production levels in a much shorter time than is currently experienced

  17. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: EXEL INDUSTRIAL AIRMIX SPRAY GUN

    Science.gov (United States)

    The Environmental Technology Verification Program has partnered with Concurrent Technologies Corp. to verify innovative coatings and coating equipment technologies for reducing air emissions. This report describes the performance of EXEL Industrial's Kremlin Airmix high transfer ...

  18. CIT photoheliograph functional verification unit test program

    Science.gov (United States)

    1973-01-01

    Tests of the 2/3-meter photoheliograph functional verification unit FVU were performed with the FVU installed in its Big Bear Solar Observatory vacuum chamber. Interferometric tests were run both in Newtonian (f/3.85) and Gregorian (f/50) configurations. Tests were run in both configurations with optical axis horizontal, vertical, and at 45 deg to attempt to determine any gravity effects on the system. Gravity effects, if present, were masked by scatter in the data associated with the system wavefront error of 0.16 lambda rms ( = 6328A) apparently due to problems in the primary mirror. Tests showed that the redesigned secondary mirror assembly works well.

  19. The Healy Clean Coal Project: Design verification tests

    International Nuclear Information System (INIS)

    Guidetti, R.H.; Sheppard, D.B.; Ubhayakar, S.K.; Weede, J.J.; McCrohan, D.V.; Rosendahl, S.M.

    1993-01-01

    As part of the Healy Clean Coal Project, TRW Inc., the supplier of the advanced slagging coal combustors, has successfully completed design verification tests on the major components of the combustion system at its Southern California test facility. These tests, which included the firing of a full-scale precombustor with a new non-storage direct coal feed system, supported the design of the Healy combustion system and its auxiliaries performed under Phase 1 of the project. Two 350 million BTU/hr combustion systems have been designed and are now ready for fabrication and erection, as part of Phase 2 of the project. These systems, along with a back-end Spray Dryer Absorber system, designed and supplied by Joy Technologies, will be integrated with a Foster Wheeler boiler for the 50 MWe power plant at Healy, Alaska. This paper describes the design verification tests and the current status of the project

  20. Transparencies used in describing the CTBT verification regime and its four monitoring technologies

    International Nuclear Information System (INIS)

    Basham, P.

    1999-01-01

    This presentation includes description of the CTBT verification regime and its four monitoring technologies, (namely, seismic monitoring, hydro acoustic monitoring, infrasound monitoring and radionuclides monitoring) CTBT global verification system, sequence of steps needed for installing an international monitoring system station which includes: site survey, site preparation and construction, equipment procurement and installation, final tests and certification

  1. Consortium for Verification Technology Fellowship Report.

    Energy Technology Data Exchange (ETDEWEB)

    Sadler, Lorraine E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-06-01

    As one recipient of the Consortium for Verification Technology (CVT) Fellowship, I spent eight days as a visiting scientist at the University of Michigan, Department of Nuclear Engineering and Radiological Sciences (NERS). During this time, I participated in multiple department and research group meetings and presentations, met with individual faculty and students, toured multiple laboratories, and taught one-half of a one-unit class on Risk Analysis in Nuclear Arms control (six 1.5 hour lectures). The following report describes some of the interactions that I had during my time as well as a brief discussion of the impact of this fellowship on members of the consortium and on me/my laboratory’s technical knowledge and network.

  2. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: NEW CONDENSATOR, INC.--THE CONDENSATOR DIESEL ENGINE RETROFIT CRANKCASE VENTILATION SYSTEM

    Science.gov (United States)

    EPA's Environmental Technology Verification Program has tested New Condensator Inc.'s Condensator Diesel Engine Retrofit Crankcase Ventilation System. Brake specific fuel consumption (BSFC), the ratio of engine fuel consumption to the engine power output, was evaluated for engine...

  3. ENVIRONMENTAL TECHNOLOGY PROTOCOL VERIFICATION REPORT, EMISSIONS OF VOCS AND ALDEHYDES FROM COMMERCIAL FURNITURE (WITH APPENDICES)

    Science.gov (United States)

    As part of a U.S. Environmental Protection Agency Environmental Technology Verification program, the Research Triangle Institute (RTI) developed a test protocol for measuring volatile organic compounds and aldehydes in a large chamber. RTI convened stakeholders for the commercial...

  4. Environmental Technology Verification Report: Taconic Energy, Inc. TEA Fuel Additive

    Science.gov (United States)

    The Greenhouse Gas Technology Center (GHG Center) is one of six verification organizations operating under EPA’s ETV program. One sector of significant interest to GHG Center stakeholders is transportation - particularly technologies that result in fuel economy improvements. Taco...

  5. ENVIRONMENTAL TECHNOLOGY VERIFICATION PROGRAM: PROTOCOL FOR THE VERIFICATION OF GROUTING MATERIALS FOR INFRASTRUCTURE REHABILITATION AT THE UNIVERSITY OF HOUSTON - CIGMAT

    Science.gov (United States)

    This protocol was developed under the Environmental Protection Agency's Environmental Technology Verification (ETV) Program, and is intended to be used as a guide in preparing laboratory test plans for the purpose of verifying the performance of grouting materials used for infra...

  6. System and Component Software Specification, Run-time Verification and Automatic Test Generation, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The following background technology is described in Part 5: Run-time Verification (RV), White Box Automatic Test Generation (WBATG). Part 5 also describes how WBATG...

  7. Test/QA plan for the verification testing of diesel exhaust catalysts, particulate filters and engine modification control technologies for highway and nonroad use diesel engines

    Science.gov (United States)

    This ETV test/QA plan for heavy-duty diesel engine testing at the Southwest Research Institute’s Department of Emissions Research (DER) describes how the Federal Test Procedure (FTP), as listed in 40 CFR Part 86 for highway engines and 40 CFR Part 89 for nonroad engines, will be ...

  8. Test/QA plan for the verification testing of selective catalytic reduction control technologies for highway, nonroad use heavy-duty diesel engines

    Science.gov (United States)

    This ETV test/QA plan for heavy-duty diesel engine testing at the Southwest Research Institute’s Department of Emissions Research (DER) describes how the Federal Test Procedure (FTP), as listed in 40 CFR Part 86 for highway engines and 40 CFR Part 89 for nonroad engines, will be ...

  9. ANIMAL WASTE IMPACT ON SOURCE WATERSAIDED BY EPA/NSF ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) SOURCE WATER PROTECTION PILOT

    Science.gov (United States)

    The Environmental Technology Verification Program (ETV) was established in 1995 by the U.S. Environmental Protection Agency to encourage the development and commercialization of new environmental technologies through third part testing and reporting of performance data. By ensur...

  10. Fiscal 1997 report of the development of high efficiency waste power generation technology. No.2 volume. Pilot plant verification test; Kokoritsu haikibutsu hatsuden gijutsu kaihatsu (pilot plant jissho shiken). 1997 nendo hokokusho (daini bunsatsu)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    As to a high efficiency waste power generation system using general waste as fuel, the details of the following were described: design/construction management and operational study of pilot plant, design/manufacture/construction of pilot plant, and study of an optimal total system. Concerning the construction management and operational study, the paper described the application for governmental/official inspection procedures and taking inspection, process management of pilot plant, site patrol, safety management, management of trial run of pilot plant, drawing-up of a verification test plan and test run, etc. Relating to the design/manufacture/construction of pilot plant, an outline of the pilot plant was described. The paper also stated points to be considered in design of furnace structure and boiler structure, points to be considered of the verification test, etc. As to the study of an optimal total system, the following were described: survey of waste gasification/slagging power generation technology, basic study on RDF production process, survey of trends of waste power generation technology in the U.S., etc. 52 refs., 149 figs., 121 tabs.

  11. Test/QA Plan For Verification Of Anaerobic Digester For Energy Production And Pollution Prevention

    Science.gov (United States)

    The ETV-ESTE Program conducts third-party verification testing of commercially available technologies that improve the environmental conditions in the U.S. A stakeholder committee of buyers and users of such technologies guided the development of this test on anaerobic digesters...

  12. Testing Conducted for Lithium-Ion Cell and Battery Verification

    Science.gov (United States)

    Reid, Concha M.; Miller, Thomas B.; Manzo, Michelle A.

    2004-01-01

    The NASA Glenn Research Center has been conducting in-house testing in support of NASA's Lithium-Ion Cell Verification Test Program, which is evaluating the performance of lithium-ion cells and batteries for NASA mission operations. The test program is supported by NASA's Office of Aerospace Technology under the NASA Aerospace Flight Battery Systems Program, which serves to bridge the gap between the development of technology advances and the realization of these advances into mission applications. During fiscal year 2003, much of the in-house testing effort focused on the evaluation of a flight battery originally intended for use on the Mars Surveyor Program 2001 Lander. Results of this testing will be compared with the results for similar batteries being tested at the Jet Propulsion Laboratory, the Air Force Research Laboratory, and the Naval Research Laboratory. Ultimately, this work will be used to validate lithium-ion battery technology for future space missions. The Mars Surveyor Program 2001 Lander battery was characterized at several different voltages and temperatures before life-cycle testing was begun. During characterization, the battery displayed excellent capacity and efficiency characteristics across a range of temperatures and charge/discharge conditions. Currently, the battery is undergoing lifecycle testing at 0 C and 40-percent depth of discharge under low-Earth-orbit (LEO) conditions.

  13. Environmental Technology Verification Report for Abraxis Ecologenia® Ethynylestradiol (EE2) Microplate Enzyme-Linked Immunosorbent Assay (ELISA) Test Kits

    Science.gov (United States)

    The EPA's National Risk Management Research Laboratory (NRMRL) and its verification organization partner, Battelle, operate the Advanced Monitoring Systems (AMS) Center under ETV. The AMS Center recently evaluated the performance of the Abraxis Ecologenia Ethynylestradiol (EE2) ...

  14. U.S. ENVIRONMENTAL PROTECTION AGENCY (EPA) ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) PROGRAM: ARSENIC MONITORING TECHNOLOGIES

    Science.gov (United States)

    The U.S. Environmental Protection Agency Environmental Technology Verification (ETV) program evaluates the performance of innovative air, water, pollution prevention and monitoring technologies that have the potential to improve human health and the environment. This technology ...

  15. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT LASER TOUCH AND TECHNOLOGIES, LLC LASER TOUCH MODEL LT-B512

    Science.gov (United States)

    The Environmental Technology Verification report discusses the technology and performance of Laser Touch model LT-B512 targeting device manufactured by Laser Touch and Technologies, LLC, for manual spray painting operations. The relative transfer efficiency (TE) improved an avera...

  16. Environmental Technology Verification Report - Electric Power and Heat Production Using Renewable Biogas at Patterson Farms

    Science.gov (United States)

    The U.S. EPA operates the Environmental Technology Verification program to facilitate the deployment of innovative technologies through performance verification and information dissemination. A technology area of interest is distributed electrical power generation, particularly w...

  17. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: DUST SUPPRESSANT PRODUCTS: SYNTECH PRODUCTS CORPORATION'S PETROTAC

    Science.gov (United States)

    Dust suppressant products used to control particulate emissions from unpaved roads are among the technologies evaluated by the Air Pollution Control Technology (APCT) Verification Center, part of the U.S. Environmental Protection Agency's Environmental Technology Verification (ET...

  18. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: DUST SUPPRESSANT PRODUCTS: SYNTECH PRODUCTS CORPORATION'S TECHSUPPRESS

    Science.gov (United States)

    Dust suppressant products used to control particulate emissions from unpaved roads are among the technologies evaluated by the Air Pollution Control Technology (APCT) Verification Center, part of the U.S. Environmental Protection Agency's Environmental Technology Verification (ET...

  19. Technical workshop on safeguards, verification technologies, and other related experience

    International Nuclear Information System (INIS)

    1998-01-01

    The aim of the Technical Workshop on safeguards was to encourage a clearer understanding of the IAEA Safeguards System, its origins and evolution and the present state of the art. Presentations held by the IAEA officials and outside experts examined as well other components of the non-proliferation regime, the current practices and procedures, and the future prospects. A series of presentations described the characteristics of the interaction between global and regional verification systems and described relevant past and present experience. Prominence given to such state of the art verification technologies as environmental sampling, satellite imaging and monitoring thorough remote and unattended techniques demonstrated, beyond any doubt, the essentially dynamic nature of verification. It is generally acknowledged that there have been major achievements in preventing spread of nuclear weapons, but no verification system can in itself prevent proliferation

  20. Technical workshop on safeguards, verification technologies, and other related experience

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-12-31

    The aim of the Technical Workshop on safeguards was to encourage a clearer understanding of the IAEA Safeguards System, its origins and evolution and the present state of the art. Presentations held by the IAEA officials and outside experts examined as well other components of the non-proliferation regime, the current practices and procedures, and the future prospects. A series of presentations described the characteristics of the interaction between global and regional verification systems and described relevant past and present experience. Prominence given to such state of the art verification technologies as environmental sampling, satellite imaging and monitoring thorough remote and unattended techniques demonstrated, beyond any doubt, the essentially dynamic nature of verification. It is generally acknowledged that there have been major achievements in preventing spread of nuclear weapons, but no verification system can in itself prevent proliferation Refs, figs, tabs

  1. Environmental Technology Verification Report for Abraxis 17β-Estradiol (E2) Magnetic Particle Enzyme-Linked Immunosorbent Assay (ELISA) Test Kits

    Science.gov (United States)

    The EPA's National Risk Management Research Laboratory (NRMRL) and its verification organization partner, Battelle, operate the Advanced Monitoring Systems (AMS) Center under ETV. The AMS Center recently evaluated the performance of the Abraxis 17(beta)-estradiol (E2) magnetic p...

  2. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT - BAGHOUSE FILTRATION PRODUCTS - TETRATEC PTFE TECHNOLOGIES TETRATEX 8005

    Science.gov (United States)

    Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of th...

  3. U.S. ENVIRONMENTAL PROTECTION AGENCY (EPA) ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) PROGRAM: ARSENIC TREATMENT TECHNOLOGIES

    Science.gov (United States)

    The U.S. Environmental Protection Agency (EPA) Environmental Technology Verification (ETV) program evaluates the performance of innovative air, water, pollution prevention and monitoring technologies that have the potential to improve human health and the environment. This techn...

  4. TET-1- A German Microsatellite for Technology On -Orbit Verification

    Science.gov (United States)

    Föckersperger, S.; Lattner, K.; Kaiser, C.; Eckert, S.; Bärwald, W.; Ritzmann, S.; Mühlbauer, P.; Turk, M.; Willemsen, P.

    2008-08-01

    Due to the high safety standards in the space industry every new product must go through a verification process before qualifying for operation in a space system. Within the verification process the payload undergoes a series of tests which prove that it is in accordance with mission requirements in terms of function, reliability and safety. Important verification components are the qualification for use on the ground as well as the On-Orbit Verification (OOV), i.e. proof that the product is suitable for use under virtual space conditions (on-orbit). Here it is demonstrated that the product functions under conditions which cannot or can only be partially simulated on the ground. The OOV-Program of the DLR serves to bridge the gap between the product tested and qualified on the ground and the utilization of the product in space. Due to regular and short-term availability of flight opportunities industry and research facilities can verify their latest products under space conditions and demonstrate their reliability and marketability. The Technologie-Erprobungs-Tr&äger TET (Technology Experiments Carrier) comprises the core elements of the OOV Program. A programmatic requirement of the OOV Program is that a satellite bus already verified in orbit be used in the first segment of the program. An analysis of suitable satellite buses showed that a realization of the TET satellite bus based on the BIRD satellite bus fulfilled the programmatic requirements best. Kayser-Threde was selected by DLR as Prime Contractor to perform the project together with its major subcontractors Astro- und Feinwerktechnik, Berlin for the platform development and DLR-GSOC for the ground segment development. TET is now designed to be a modular and flexible micro-satellite for any orbit between 450 and 850 km altitude and inclination between 53° and SSO. With an overall mass of 120 kg TET is able to accommodate experiments of up to 50 kg. A multipurpose payload supply systemThere is

  5. Technology verification phase. Dynamic isotope power system. Final report

    International Nuclear Information System (INIS)

    Halsey, D.G.

    1982-01-01

    The Phase I requirements of the Kilowatt Isotope Power System (KIPS) program were to make a detailed Flight System Conceptual Design (FSCD) for an isotope fueled organic Rankine cycle power system and to build and test a Ground Demonstration System (GDS) which simulated as closely as possible the operational characteristics of the FSCD. The activities and results of Phase II, the Technology Verification Phase, of the program are reported. The objectives of this phase were to increase system efficiency to 18.1% by component development, to demonstrate system reliability by a 5000 h endurance test and to update the flight system design. During Phase II, system performance was improved from 15.1% to 16.6%, an endurance test of 2000 h was performed while the flight design analysis was limited to a study of the General Purpose Heat Source, a study of the regenerator manufacturing technique and analysis of the hardness of the system to a laser threat. It was concluded from these tests that the GDS is basically prototypic of a flight design; all components necessary for satisfactory operation were demonstrated successfully at the system level; over 11,000 total h of operation without any component failure attested to the inherent reliability of this type of system; and some further development is required, specifically in the area of performance

  6. Technology verification phase. Dynamic isotope power system. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Halsey, D.G.

    1982-03-10

    The Phase I requirements of the Kilowatt Isotope Power System (KIPS) program were to make a detailed Flight System Conceptual Design (FSCD) for an isotope fueled organic Rankine cycle power system and to build and test a Ground Demonstration System (GDS) which simulated as closely as possible the operational characteristics of the FSCD. The activities and results of Phase II, the Technology Verification Phase, of the program are reported. The objectives of this phase were to increase system efficiency to 18.1% by component development, to demonstrate system reliability by a 5000 h endurance test and to update the flight system design. During Phase II, system performance was improved from 15.1% to 16.6%, an endurance test of 2000 h was performed while the flight design analysis was limited to a study of the General Purpose Heat Source, a study of the regenerator manufacturing technique and analysis of the hardness of the system to a laser threat. It was concluded from these tests that the GDS is basically prototypic of a flight design; all components necessary for satisfactory operation were demonstrated successfully at the system level; over 11,000 total h of operation without any component failure attested to the inherent reliability of this type of system; and some further development is required, specifically in the area of performance. (LCL)

  7. Dynamic Isotope Power System: technology verification phase, program plan, 1 October 1978

    International Nuclear Information System (INIS)

    1979-01-01

    The technology verification phase program plan of the Dynamic Isotope Power System (DIPS) project is presented. DIPS is a project to develop a 0.5 to 2.0 kW power system for spacecraft using an isotope heat source and a closed-cycle Rankine power-system with an organic working fluid. The technology verification phase's purposes are to increase the system efficiency to over 18%, to demonstrate system reliability, and to provide an estimate for flight test scheduling. Progress toward these goals is reported

  8. Environmental Technology Verification: Baghouse Filtration Products--TDC Filter Manufacturing, Inc., SB025 Filtration Media

    Science.gov (United States)

    The U.S. Environmental Protection Agency (EPA) has created the Environmental Technology Verification (ETV) Program to facilitate the deployment of innovative or improved environmental technologies through performance verification and dissemination of information. ETV seeks to ach...

  9. GENERIC VERIFICATION PROTOCOL FOR AQUEOUS CLEANER RECYCLING TECHNOLOGIES

    Science.gov (United States)

    This generic verification protocol has been structured based on a format developed for ETV-MF projects. This document describes the intended approach and explain plans for testing with respect to areas such as test methodology, procedures, parameters, and instrumentation. Also ...

  10. Reliability program plan for the Kilowatt Isotope Power System (KIPS) technology verification phase

    International Nuclear Information System (INIS)

    1978-01-01

    Ths document is an integral part of the Kilowatt Isotope Power System (KIPS) Program Plan. This document defines the KIPS Reliability Program Plan for the Technology Verification Phase. This document delineates the reliability assurance tasks that are to be accomplished by Sundstrand and its suppliers during the design, fabrication and testing of the KIPS

  11. Test/QA Plan for Verification of Radio Frequency Identification (RFID) for Tracking Hazardous Waste Shipments across International Borders

    Science.gov (United States)

    The verification test will be conducted under the auspices of the U.S. Environmental Protection Agency (EPA) through the Environmental Technology Verification (ETV) Program. It will be performed by Battelle, which is managing the ETV Advanced Monitoring Systems (AMS) Center throu...

  12. DIESEL ENGINE RETROFIT TECHNOLOGY VERIFICATION (POSTER)

    Science.gov (United States)

    ETV is presenting a poster at the EPA's 2005 Science Forum from May 16-18, 2005 in Washington, DC. This poster will contain a summary of the performance results realized by the six verified diesel retrofit technologies, as well as potential impacts that could be realized if sigi...

  13. BAGHOUSE FILTRATION PRODUCTS VERIFICATION TESTING, HOW IT BENEFITS THE BOILER BAGHOUSE OPERATOR

    Science.gov (United States)

    The paper describes the Environmental Technology Verification (ETV) Program for baghouse filtration products developed by the Air Pollution Control Technology Verification Center, one of six Centers under the ETV Program, and discusses how it benefits boiler baghouse operators. A...

  14. Development of nuclear thermal hydraulic verification test and evaluation technology - Development of fundamental technique for experiment of natural circulation phenomena in PWR systems

    Energy Technology Data Exchange (ETDEWEB)

    Park, Goon Cherl; Lee, Tae Ho; Kim, Moon Oh; Kim, Hak Joon [Seoul National University, Seoul (Korea)

    2000-04-01

    The dimensional analysis applied two-fluid model of CFX-4,2 were performed. For verification of analysis results, experimental measurement data of two-phase flow parameters in subcooled boiling flow were produced for vertical(0 deg) and inclination (60 deg). And through comparison analysis and experiments the application possibility of various two -phase flow models and the analysis ability of code were evaluated. Measurement technique of bubble velocity in two-phase flow using backscattering standard LDV was investigated from slug to bubbly flow regime. The range of velocity measured is from 0.2 to 1.5 m/s and that of bubble size is from 2 to 20 mm. For local temperature of boiling flow measurement, microthermocouple were manufactured and local liquid and vapor temperatures were measured in pool boiling and boiling flow. 66 refs., 74 figs., 4 tabs. (Author)

  15. Development of evaluation and performance verification technology for radiotherapy radiation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. Y.; Jang, S. Y.; Kim, B. H. and others

    2005-02-15

    No matter how much the importance is emphasized, the exact assessment of the absorbed doses administered to the patients to treat the various diseases such as lately soaring malignant tumors with the radiotherapy practices is the most important factor. In reality, several over-exposed patients from the radiotherapy practice become very serious social issues. Especially, the development of a technology to exactly assess the high doses and high energies (In general, dose administered to the patients with the radiotherapy practices are very huge doses, and they are about three times higher than the lethal doses) generated by the radiation generators and irradiation equipment is a competing issue to be promptly conducted. Over fifty medical centers in Korea operate the radiation generators and irradiation equipment for the radiotherapy practices. However, neither the legal and regulatory systems to implement a quality assurance program are sufficiently stipulated nor qualified personnel who could run a program to maintain the quality assurance and control of those generators and equipment for the radiotherapy practices in the medical facilities are sufficiently employed. To overcome the above deficiencies, a quality assurance program such as those developed in the technically advanced countries should be developed to exactly assess the doses administered to patients with the radiotherapy practices and develop the necessary procedures to maintain the continuing performance of the machine or equipment for the radiotherapy. The QA program and procedures should induce the fluent calibration of the machine or equipment with quality, and definitely establish the safety of patients in the radiotherapy practices. In this study, a methodology for the verification and evaluation of the radiotherapy doses is developed, and several accurate measurements, evaluations of the doses delivered to patients and verification of the performance of the therapy machine and equipment are

  16. Design verification testing for fuel element type CAREM

    International Nuclear Information System (INIS)

    Martin Ghiselli, A.; Bonifacio Pulido, K.; Villabrille, G.; Rozembaum, I.

    2013-01-01

    The hydraulic and hydrodynamic characterization tests are part of the design verification process of a nuclear fuel element prototype and its components. These tests are performed in a low pressure and temperature facility. The tests requires the definition of the simulation parameters for setting the test conditions, the results evaluation to feedback mathematical models, extrapolated the results to reactor conditions and finally to decide the acceptability of the tested prototype. (author)

  17. Sierra/SolidMechanics 4.48 Verification Tests Manual.

    Energy Technology Data Exchange (ETDEWEB)

    Plews, Julia A.; Crane, Nathan K; de Frias, Gabriel Jose; Le, San; Littlewood, David John; Merewether, Mark Thomas; Mosby, Matthew David; Pierson, Kendall H.; Porter, Vicki L.; Shelton, Timothy; Thomas, Jesse David; Tupek, Michael R.; Veilleux, Michael; Xavier, Patrick G.

    2018-03-01

    Presented in this document is a small portion of the tests that exist in the Sierra / SolidMechanics (Sierra / SM) verification test suite. Most of these tests are run nightly with the Sierra / SM code suite, and the results of the test are checked versus the correct analytical result. For each of the tests presented in this document, the test setup, a description of the analytic solution, and comparison of the Sierra / SM code results to the analytic solution is provided. Mesh convergence is also checked on a nightly basis for several of these tests. This document can be used to confirm that a given code capability is verified or referenced as a compilation of example problems. Additional example problems are provided in the Sierra / SM Example Problems Manual. Note, many other verification tests exist in the Sierra / SM test suite, but have not yet been included in this manual.

  18. Environmental Technology Verification: Test Report of Mobile Source Emission Control Devices--Johnson Matthey PCRT2 1000, Version 2, Filter + Diesel Oxidation Catalyst

    Science.gov (United States)

    The Johnson Matthey PCRT2 1000, v.2 system is a partial continuously regenerating technology (PCRT) system that consists of a flow-through partial filter combined with a DOC. The system is designed for low temperature exhaust resulting from intermittent loads from medium and heav...

  19. Verification test of control rod system for HTR-10

    International Nuclear Information System (INIS)

    Zhou Huizhong; Diao Xingzhong; Huang Zhiyong; Cao Li; Yang Nianzu

    2002-01-01

    There are 10 sets of control rods and driving devices in 10 MW High Temperature Gas-cooled Test Reactor (HTR-10). The control rod system is the controlling and shutdown system of HTR-10, which is designed for reactor criticality, operation, and shutdown. In order to guarantee technical feasibility, a series of verification tests were performed, including room temperature test, thermal test, test after control rod system installed in HTR-10, and test of control rod system before HTR-10 first criticality. All the tests data showed that driving devices working well, control rods running smoothly up and down, random position settling well, and exactly position indicating

  20. IMOM Field Test Study and Accuracy Verification

    National Research Council Canada - National Science Library

    Levien, Fred

    1998-01-01

    .... It was desired to obtain flight test data for both TAMPS and IMOM in order to compare their ability to accurately predict the effects of Radar Terrain Masking (RTM). It was initially planned to have NPS compare predictive data from both of these systems and then do analysis of how they compared to actual field test data.

  1. EPFM verification by a large scale test

    International Nuclear Information System (INIS)

    Okamura, H.; Yagawa, G.; Hidaka, T.; Sato, M.; Urabe, Y.; Iida, M.

    1993-01-01

    Step B test was carried out as one of the elastic plastic fracture mechanics (EPFR) study in Japanese PTS integrity research project. In step B test bending load was applied to the large flat specimen with thermal shock. Tensile load was kept constant during the test. Estimated stable crack growth at the deepest point of the crack was 3 times larger than the experimental value in the previous analysis. In order to diminish the difference between them from the point of FEM modeling, more precise FEM mesh was introduced. According to the new analysis, the difference considerably decreased. That is, stable crack growth evaluation was improved by adopting precise FEM model near the crack tip and the difference was almost same order as that in the NKS4-1 test analysis by MPA. 8 refs., 17 figs., 5 tabs

  2. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT - PORTABLE GAS CHROMATOGRAPH ELECTRONIC SENSOR TECHNOLOGY MODEL 4100

    Science.gov (United States)

    The U.S. Environmental Protection Agency, through the Environmental Technology Verification Program, is working to accelerate the acceptance and use of innovative technologies that improve the way the United States manages its environmental problems. As part of this program, the...

  3. Support of Construction and Verification of Out-of-Pile Fuel Assembly Test Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Park, Nam Gyu; Kim, K. T.; Park, J. K. [KNF, Daejeon (Korea, Republic of)] (and others)

    2006-12-15

    Fuel assembly and components should be verified by the out-of-pile test facilities in order to load the developed fuel in reactor. Even though most of the component-wise tests have been performed using the facilities in land, the assembly-wise tests has been depended on the oversees' facility due to the lack of the facilities. KAERI started to construct the assembly-wise mechanical/hydraulic test facilities and KNF, as an end user, is supporting the mechanical/hydraulic test facility construction by using the technologies studied through the fuel development programs. The works performed are as follows: - Test assembly shipping container design and manufacturing support - Fuel handling tool design : Gripper, Upper and lower core simulators for assembly mechanical test facility, Internals for assembly hydraulic test facility - Manufacture of test specimens : skeleton and assembly for preliminary functional verification of assembly mechanical/hydraulic test facilities, two assemblies for the verification of assembly mechanical/hydraulic test facilities, Instrumented rod design and integrity evaluation - Verification of assembly mechanical/hydraulic test facilities : test data evaluation.

  4. Support of Construction and Verification of Out-of-Pile Fuel Assembly Test Facilities

    International Nuclear Information System (INIS)

    Park, Nam Gyu; Kim, K. T.; Park, J. K.

    2006-12-01

    Fuel assembly and components should be verified by the out-of-pile test facilities in order to load the developed fuel in reactor. Even though most of the component-wise tests have been performed using the facilities in land, the assembly-wise tests has been depended on the oversees' facility due to the lack of the facilities. KAERI started to construct the assembly-wise mechanical/hydraulic test facilities and KNF, as an end user, is supporting the mechanical/hydraulic test facility construction by using the technologies studied through the fuel development programs. The works performed are as follows: - Test assembly shipping container design and manufacturing support - Fuel handling tool design : Gripper, Upper and lower core simulators for assembly mechanical test facility, Internals for assembly hydraulic test facility - Manufacture of test specimens : skeleton and assembly for preliminary functional verification of assembly mechanical/hydraulic test facilities, two assemblies for the verification of assembly mechanical/hydraulic test facilities, Instrumented rod design and integrity evaluation - Verification of assembly mechanical/hydraulic test facilities : test data evaluation

  5. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, SWINE WASTE ELECTRIC POWER AND HEAT PRODUCTION--MARTIN MACHINERY INTERNAL COMBUSTION ENGINE

    Science.gov (United States)

    Under EPA’s Environmental Technology Verification program, which provides objective and scientific third party analysis of new technology that can benefit the environment, a combined heat and power system designed by Martin Machinery was evaluated. This paper provides test result...

  6. Application verification research of cloud computing technology in the field of real time aerospace experiment

    Science.gov (United States)

    Wan, Junwei; Chen, Hongyan; Zhao, Jing

    2017-08-01

    According to the requirements of real-time, reliability and safety for aerospace experiment, the single center cloud computing technology application verification platform is constructed. At the IAAS level, the feasibility of the cloud computing technology be applied to the field of aerospace experiment is tested and verified. Based on the analysis of the test results, a preliminary conclusion is obtained: Cloud computing platform can be applied to the aerospace experiment computing intensive business. For I/O intensive business, it is recommended to use the traditional physical machine.

  7. Advanced Communication Technology Satellite (ACTS) multibeam antenna technology verification experiments

    Science.gov (United States)

    Acosta, Roberto J.; Larko, Jeffrey M.; Lagin, Alan R.

    1992-01-01

    The Advanced Communication Technology Satellite (ACTS) is a key to reaching NASA's goal of developing high-risk, advanced communications technology using multiple frequency bands to support the nation's future communication needs. Using the multiple, dynamic hopping spot beams, and advanced on board switching and processing systems, ACTS will open a new era in communications satellite technology. One of the key technologies to be validated as part of the ACTS program is the multibeam antenna with rapidly reconfigurable hopping and fixed spot beam to serve users equipped with small-aperature terminals within the coverage areas. The proposed antenna technology experiments are designed to evaluate in-orbit ACTS multibeam antenna performance (radiation pattern, gain, cross pol levels, etc.).

  8. Current Research on Containment Technologies for Verification Activities: Advanced Tools for Maintaining Continuity of Knowledge

    International Nuclear Information System (INIS)

    Smartt, H.; Kuhn, M.; Krementz, D.

    2015-01-01

    The U.S. National Nuclear Security Administration (NNSA) Office of Non-proliferation and Verification Research and Development currently funds research on advanced containment technologies to support Continuity of Knowledge (CoK) objectives for verification regimes. One effort in this area is the Advanced Tools for Maintaining Continuity of Knowledge (ATCK) project. Recognizing that CoK assurances must withstand potential threats from sophisticated adversaries, and that containment options must therefore keep pace with technology advances, the NNSA research and development on advanced containment tools is an important investment. The two ATCK efforts underway at present address the technical containment requirements for securing access points (loop seals) and protecting defined volumes. Multiple U.S. national laboratories are supporting this project: Sandia National Laboratories (SNL), Savannah River National Laboratory (SRNL), and Oak Ridge National Laboratory (ORNL). SNL and SRNL are developing the ''Ceramic Seal,'' an active loop seal that integrates multiple advanced security capabilities and improved efficiency housed within a small-volume ceramic body. The development includes an associated handheld reader and interface software. Currently at the prototype stage, the Ceramic Seal will undergo a series of tests to determine operational readiness. It will be field tested in a representative verification trial in 2016. ORNL is developing the Whole Volume Containment Seal (WCS), a flexible conductive fabric capable of enclosing various sizes and shapes of monitored items. The WCS includes a distributed impedance measurement system for imaging the fabric surface area and passive tamper-indicating features such as permanent-staining conductive ink. With the expected technology advances from the Ceramic Seal and WCS, the ATCK project takes significant steps in advancing containment technologies to help maintain CoK for various verification

  9. Verification test of an engineering-scale multi-purpose radwaste incinerator

    International Nuclear Information System (INIS)

    Wang Peiyi; Zhou Lianquan; Ma Mingxie; Qiu Mingcai; Yang Liguo; Li Xiaohai; Zhang Xiaobin; Lu Xiaowu; Dong Jingling; Wang Xujin; Li Chuanlian; Yang Baomin

    2002-01-01

    The verification test of an engineering-scale multi-purpose radwaste incinerator was implemented. The test items include performance determination for the system when solid wastes (include resins) or spent oil were incinerating and off gas was cleaning, tracer test for determining decontamination factor and 72 h continuos running test. 500 h tests verify the reliability and feasibility of designs of technological process, main structure, instrument control and system safety. The incineration system ran smoothly, devices and instruments worked stably. The specifications such as capacity, volume reduction factor, carbon remainder in ash and decontamination factor all meet the design requirements

  10. Test-driven verification/validation of model transformations

    Institute of Scientific and Technical Information of China (English)

    László LENGYEL; Hassan CHARAF

    2015-01-01

    Why is it important to verify/validate model transformations? The motivation is to improve the quality of the trans-formations, and therefore the quality of the generated software artifacts. Verified/validated model transformations make it possible to ensure certain properties of the generated software artifacts. In this way, verification/validation methods can guarantee different requirements stated by the actual domain against the generated/modified/optimized software products. For example, a verified/ validated model transformation can ensure the preservation of certain properties during the model-to-model transformation. This paper emphasizes the necessity of methods that make model transformation verified/validated, discusses the different scenarios of model transformation verification and validation, and introduces the principles of a novel test-driven method for verifying/ validating model transformations. We provide a solution that makes it possible to automatically generate test input models for model transformations. Furthermore, we collect and discuss the actual open issues in the field of verification/validation of model transformations.

  11. Formal Verification of Digital Protection Logic and Automatic Testing Software

    Energy Technology Data Exchange (ETDEWEB)

    Cha, S. D.; Ha, J. S.; Seo, J. S. [KAIST, Daejeon (Korea, Republic of)

    2008-06-15

    - Technical aspect {center_dot} It is intended that digital I and C software have safety and reliability. Project results help the software to acquire license. Software verification technique, which results in this project, can be to use for digital NPP(Nuclear power plant) in the future. {center_dot} This research introduces many meaningful results of verification on digital protection logic and suggests I and C software testing strategy. These results apply to verify nuclear fusion device, accelerator, nuclear waste management and nuclear medical device that require dependable software and high-reliable controller. Moreover, These can be used for military, medical or aerospace-related software. - Economical and industrial aspect {center_dot} Since safety of digital I and C software is highly import, It is essential for the software to be verified. But verification and licence acquisition related to digital I and C software face high cost. This project gives economic profit to domestic economy by using introduced verification and testing technique instead of foreign technique. {center_dot} The operation rate of NPP will rise, when NPP safety critical software is verified with intellectual V and V tool. It is expected that these software substitute safety-critical software that wholly depend on foreign. Consequently, the result of this project has high commercial value and the recognition of the software development works will be able to be spread to the industrial circles. - Social and cultural aspect People expect that nuclear power generation contributes to relieving environmental problems because that does not emit more harmful air pollution source than other power generations. To give more trust and expectation about nuclear power generation to our society, we should make people to believe that NPP is highly safe system. In that point of view, we can present high-reliable I and C proofed by intellectual V and V technique as evidence

  12. US monitoring and verification technology: on-site inspection experience and future challenges

    International Nuclear Information System (INIS)

    Gullickson, R.L.; Carlson, D.; Ingraham, J.; Laird, B.

    2013-01-01

    The United States has a long and successful history of cooperation with treaty partners in monitoring and verification. For strategic arms reduction treaties, our collaboration has resulted in the development and application of systems with limited complexity and intrusiveness. As we progress beyond New START (NST) along the 'road to zero', the reduced number of nuclear weapons is likely to require increased confidence in monitoring and verification techniques. This may place increased demands on the technology to verify the presence of a nuclear weapon and even confirm the presence of a certain type. Simultaneously, this technology must include the ability to protect each treaty partner's sensitive nuclear weapons information. Mutual development of this technology by treaty partners offers the best approach for acceptance in treaty negotiations. This same approach of mutual cooperation and development is essential for developing nuclear test monitoring technology in support of the Comprehensive Nuclear Test Ban Treaty (CTBT). Our ability to detect low yield and evasive testing will be enhanced through mutually developed techniques and experiments using laboratory laser experiments and high explosives tests in a variety of locations and geologies. (authors)

  13. Technique for unit testing of safety software verification and validation

    International Nuclear Information System (INIS)

    Li Duo; Zhang Liangju; Feng Junting

    2008-01-01

    The key issue arising from digitalization of the reactor protection system for nuclear power plant is how to carry out verification and validation (V and V), to demonstrate and confirm the software that performs reactor safety functions is safe and reliable. One of the most important processes for software V and V is unit testing, which verifies and validates the software coding based on concept design for consistency, correctness and completeness during software development. The paper shows a preliminary study on the technique for unit testing of safety software V and V, focusing on such aspects as how to confirm test completeness, how to establish test platform, how to develop test cases and how to carry out unit testing. The technique discussed here was successfully used in the work of unit testing on safety software of a digital reactor protection system. (authors)

  14. The concept verification testing of materials science payloads

    Science.gov (United States)

    Griner, C. S.; Johnston, M. H.; Whitaker, A.

    1976-01-01

    The concept Verification Testing (CVT) project at the Marshall Space Flight Center, Alabama, is a developmental activity that supports Shuttle Payload Projects such as Spacelab. It provides an operational 1-g environment for testing NASA and other agency experiment and support systems concepts that may be used in shuttle. A dedicated Materials Science Payload was tested in the General Purpose Laboratory to assess the requirements of a space processing payload on a Spacelab type facility. Physical and functional integration of the experiments into the facility was studied, and the impact of the experiments on the facility (and vice versa) was evaluated. A follow-up test designated CVT Test IVA was also held. The purpose of this test was to repeat Test IV experiments with a crew composed of selected and trained scientists. These personnel were not required to have prior knowledge of the materials science disciplines, but were required to have a basic knowledge of science and the scientific method.

  15. Testing Template and Testing Concept of Operations for Speaker Authentication Technology

    National Research Council Canada - National Science Library

    Sipko, Marek M

    2006-01-01

    This thesis documents the findings of developing a generic testing template and supporting concept of operations for speaker verification technology as part of the Iraqi Enrollment via Voice Authentication Project (IEVAP...

  16. Cassini's Test Methodology for Flight Software Verification and Operations

    Science.gov (United States)

    Wang, Eric; Brown, Jay

    2007-01-01

    The Cassini spacecraft was launched on 15 October 1997 on a Titan IV-B launch vehicle. The spacecraft is comprised of various subsystems, including the Attitude and Articulation Control Subsystem (AACS). The AACS Flight Software (FSW) and its development has been an ongoing effort, from the design, development and finally operations. As planned, major modifications to certain FSW functions were designed, tested, verified and uploaded during the cruise phase of the mission. Each flight software upload involved extensive verification testing. A standardized FSW testing methodology was used to verify the integrity of the flight software. This paper summarizes the flight software testing methodology used for verifying FSW from pre-launch through the prime mission, with an emphasis on flight experience testing during the first 2.5 years of the prime mission (July 2004 through January 2007).

  17. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, ENVIRONMENTAL DECISION SUPPORT SOFTWARE, UNIVERSITY OF TENNESSEE RESEARCH CORPORATION, SPATIAL ANALYSIS AND DECISION ASSISTANCE (SADA)

    Science.gov (United States)

    The U.S. Environmental Protection Agency (EPA) has created the Environmental Technology Verification Program (ETV) to facilitate the deployment of innovative or improved environmental technologies through performance verification and dissemination of information. The goal of the...

  18. Verification test report on a solar heating and hot water system

    Science.gov (United States)

    1978-01-01

    Information is provided on the development, qualification and acceptance verification of commercial solar heating and hot water systems and components. The verification includes the performances, the efficiences and the various methods used, such as similarity, analysis, inspection, test, etc., that are applicable to satisfying the verification requirements.

  19. Universal Verification Methodology Based Register Test Automation Flow.

    Science.gov (United States)

    Woo, Jae Hun; Cho, Yong Kwan; Park, Sun Kyu

    2016-05-01

    In today's SoC design, the number of registers has been increased along with complexity of hardware blocks. Register validation is a time-consuming and error-pron task. Therefore, we need an efficient way to perform verification with less effort in shorter time. In this work, we suggest register test automation flow based UVM (Universal Verification Methodology). UVM provides a standard methodology, called a register model, to facilitate stimulus generation and functional checking of registers. However, it is not easy for designers to create register models for their functional blocks or integrate models in test-bench environment because it requires knowledge of SystemVerilog and UVM libraries. For the creation of register models, many commercial tools support a register model generation from register specification described in IP-XACT, but it is time-consuming to describe register specification in IP-XACT format. For easy creation of register model, we propose spreadsheet-based register template which is translated to IP-XACT description, from which register models can be easily generated using commercial tools. On the other hand, we also automate all the steps involved integrating test-bench and generating test-cases, so that designers may use register model without detailed knowledge of UVM or SystemVerilog. This automation flow involves generating and connecting test-bench components (e.g., driver, checker, bus adaptor, etc.) and writing test sequence for each type of register test-case. With the proposed flow, designers can save considerable amount of time to verify functionality of registers.

  20. CATS Deliverable 5.1 : CATS verification of test matrix and protocol

    OpenAIRE

    Uittenbogaard, J.; Camp, O.M.G.C. op den; Montfort, S. van

    2016-01-01

    This report summarizes the work conducted within work package (WP) 5 "Verification of test matrix and protocol" of the Cyclist AEB testing system (CATS) project. It describes the verification process of the draft CATS test matrix resulting from WP1 and WP2, and the feasibility of meeting requirements set by CATS consortium based on requirements in Euro NCAP AEB protocols regarding accuracy, repeatability and reproducibility using the developed test hardware. For the cases where verification t...

  1. Performance verification tests of JT-60SA CS model coil

    Energy Technology Data Exchange (ETDEWEB)

    Obana, Tetsuhiro, E-mail: obana.tetsuhiro@LHD.nifs.ac.jp [National Institute for Fusion Science, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan); Murakami, Haruyuki [Japan Atomic Energy Agency, 801-1 Mukoyama, Naka, Ibaraki 311-0193 (Japan); Takahata, Kazuya; Hamaguchi, Shinji; Chikaraishi, Hirotaka; Mito, Toshiyuki; Imagawa, Shinsaku [National Institute for Fusion Science, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan); Kizu, Kaname; Natsume, Kyohei; Yoshida, Kiyoshi [Japan Atomic Energy Agency, 801-1 Mukoyama, Naka, Ibaraki 311-0193 (Japan)

    2015-11-15

    Highlights: • The performance of the JT-60SA CS model coil was verified. • The CS model coil comprised a quad-pancake wound with a Nb{sub 3}Sn CIC conductor. • The CS model coil met the design requirements. - Abstract: As a final check of the coil manufacturing method of the JT-60 Super Advanced (JT-60SA) central solenoid (CS), we verified the performance of a CS model coil. The model coil comprised a quad-pancake wound with a Nb{sub 3}Sn cable-in-conduit conductor. Measurements of the critical current, joint resistance, pressure drop, and magnetic field were conducted in the verification tests. In the critical-current measurement, the critical current of the model coil coincided with the estimation derived from a strain of −0.62% for the Nb{sub 3}Sn strands. As a result, critical-current degradation caused by the coil manufacturing process was not observed. The results of the performance verification tests indicate that the model coil met the design requirements. Consequently, the manufacturing process of the JT-60SA CS was established.

  2. Computer Forensic Function Testing: Media Preparation, Write Protection And Verification

    Directory of Open Access Journals (Sweden)

    Yinghua (David Guo

    2010-06-01

    Full Text Available Normal 0 false false false EN-US JA AR-SA The growth in the computer forensic field has created a demand for new software (or increased functionality to existing software and a means to verify that this software is truly forensic i.e. capable of meeting the requirements of the trier of fact. In this work, we review our previous work---a function oriented testing framework for validation and verification of computer forensic tools. This framework consists of three parts: function mapping, requirements specification and reference set development. Through function mapping, we give a scientific and systemical description of the fundamentals of computer forensic discipline, i.e. what functions are needed in the computer forensic investigation process. We focus this paper on the functions of media preparation, write protection and verification. Specifically, we complete the function mapping of these functions and specify their requirements. Based on this work, future work can be conducted to develop corresponding reference sets to test any tools that possess these functions.

  3. Thermal test requirements and their verification by different test methods

    International Nuclear Information System (INIS)

    Droste, B.; Wieser, G.; Probst, U.

    1993-01-01

    The paper discusses the parameters influencing the thermal test conditions for type B-packages. Criteria for different test methods (by analytical as well as by experimental means) will be developed. A comparison of experimental results from fuel oil pool and LPG fire tests will be given. (J.P.N.)

  4. Verification and testing of the RTOS for safety-critical embedded systems

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Na Young [Seoul National University, Seoul (Korea, Republic of); Kim, Jin Hyun; Choi, Jin Young [Korea University, Seoul (Korea, Republic of); Sung, Ah Young; Choi, Byung Ju [Ewha Womans University, Seoul (Korea, Republic of); Lee, Jang Soo [KAERI, Taejon (Korea, Republic of)

    2003-07-01

    Development in Instrumentation and Control (I and C) technology provides more convenience and better performance, thus, adopted in many fields. To adopt newly developed technology, nuclear industry requires rigorous V and V procedure and tests to assure reliable operation. Adoption of digital system requires verification and testing of the OS for licensing. Commercial real-time operating system (RTOS) is targeted to apply to various, unpredictable needs, which makes it difficult to verify. For this reason, simple, application-oriented realtime OS is developed for the nuclear application. In this work, we show how to verify the developed RTOS at each development lifecycle. Commercial formal tool is used in specification and verification of the system. Based on the developed model, software in C language is automatically generated. Tests are performed for two purposes; one is to identify consistency between the verified model and the generated code, the other is to find errors in the generated code. The former assumes that the verified model is correct, and the latter incorrect. Test data are generated separately to satisfy each purpose. After we test the RTOS software, we implement the test board embedded with the developed RTOS and the application software, which simulates the safety critical plant protection function. Testing to identify whether the reliability criteria is satisfied or not is also designed in this work. It results in that the developed RTOS software works well when it is embedded in the system.

  5. Verification and testing of the RTOS for safety-critical embedded systems

    International Nuclear Information System (INIS)

    Lee, Na Young; Kim, Jin Hyun; Choi, Jin Young; Sung, Ah Young; Choi, Byung Ju; Lee, Jang Soo

    2003-01-01

    Development in Instrumentation and Control (I and C) technology provides more convenience and better performance, thus, adopted in many fields. To adopt newly developed technology, nuclear industry requires rigorous V and V procedure and tests to assure reliable operation. Adoption of digital system requires verification and testing of the OS for licensing. Commercial real-time operating system (RTOS) is targeted to apply to various, unpredictable needs, which makes it difficult to verify. For this reason, simple, application-oriented realtime OS is developed for the nuclear application. In this work, we show how to verify the developed RTOS at each development lifecycle. Commercial formal tool is used in specification and verification of the system. Based on the developed model, software in C language is automatically generated. Tests are performed for two purposes; one is to identify consistency between the verified model and the generated code, the other is to find errors in the generated code. The former assumes that the verified model is correct, and the latter incorrect. Test data are generated separately to satisfy each purpose. After we test the RTOS software, we implement the test board embedded with the developed RTOS and the application software, which simulates the safety critical plant protection function. Testing to identify whether the reliability criteria is satisfied or not is also designed in this work. It results in that the developed RTOS software works well when it is embedded in the system

  6. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: MOBILE SOURCE RETROFIT AIR POLLUTION CONTROL DEVICES: CLEAN CLEAR FUEL TECHNOLOGIES, INC.’S, UNIVERSAL FUEL CELL

    Science.gov (United States)

    The U.S. EPA's Office of Research and Development operates the Environmental Technology Verification (ETV) program to facilitate the deployment of innovative technologies through performance verification and information dissemination. Congress funds ETV in response to the belief ...

  7. Verification Testing: Meet User Needs Figure of Merit

    Science.gov (United States)

    Kelly, Bryan W.; Welch, Bryan W.

    2017-01-01

    Verification is the process through which Modeling and Simulation(M&S) software goes to ensure that it has been rigorously tested and debugged for its intended use. Validation confirms that said software accurately models and represents the real world system. Credibility gives an assessment of the development and testing effort that the software has gone through as well as how accurate and reliable test results are. Together, these three components form Verification, Validation, and Credibility(VV&C), the process by which all NASA modeling software is to be tested to ensure that it is ready for implementation. NASA created this process following the CAIB (Columbia Accident Investigation Board) report seeking to understand the reasons the Columbia space shuttle failed during reentry. The reports conclusion was that the accident was fully avoidable, however, among other issues, the necessary data to make an informed decision was not there and the result was complete loss of the shuttle and crew. In an effort to mitigate this problem, NASA put out their Standard for Models and Simulations, currently in version NASA-STD-7009A, in which they detailed their recommendations, requirements and rationale for the different components of VV&C. They did this with the intention that it would allow for people receiving MS software to clearly understand and have data from the past development effort. This in turn would allow the people who had not worked with the MS software before to move forward with greater confidence and efficiency in their work. This particular project looks to perform Verification on several MATLAB (Registered Trademark)(The MathWorks, Inc.) scripts that will be later implemented in a website interface. It seeks to take note and define the limits of operation, the units and significance, and the expected datatype and format of the inputs and outputs of each of the scripts. This is intended to prevent the code from attempting to make incorrect or impossible

  8. 40 CFR 1065.520 - Pre-test verification procedures and pre-test data collection.

    Science.gov (United States)

    2010-07-01

    ... corrective action does not resolve the deficiency, you may request to use the contaminated system as an... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Pre-test verification procedures and pre-test data collection. 1065.520 Section 1065.520 Protection of Environment ENVIRONMENTAL PROTECTION...

  9. Verification Test of Hydraulic Performance for Reactor Coolant Pump

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sang Jun; Kim, Jae Shin; Ryu, In Wan; Ko, Bok Seong; Song, Keun Myung [Samjin Ind. Co., Seoul (Korea, Republic of)

    2010-01-15

    According to this project, basic design for prototype pump and model pump of reactor coolant pump and test facilities has been completed. Basic design for prototype pump to establish structure, dimension and hydraulic performance has been completed and through primary flow analysis by computational fluid dynamics(CFD), flow characteristics and hydraulic performance have been established. This pump was designed with mixed flow pump having the following design requirements; specific velocity(Ns); 1080.9(rpm{center_dot}m{sup 3}/m{center_dot}m), capacity; 3115m{sup 3}/h, total head ; 26.3m, pump speed; 1710rpm, pump efficiency; 77.0%, Impeller out-diameter; 349mm, motor output; 360kw, design pressure; 17MPaG. The features of the pump are leakage free due to no mechanical seal on the pump shaft which insures reactor's safety and law noise level and low vibration due to no cooling fan on the motor which makes eco-friendly product. Model pump size was reduced to 44% of prototype pump for the verification test for hydraulic performance of reactor coolant pump and was designed with mixed flow pump and canned motor having the following design requirements; specific speed(NS); 1060.9(rpm{center_dot}m{sup 3}/m{center_dot}m), capacity; 539.4m{sup 3}/h, total head; 21.0m, pump speed; 3476rpm, pump efficiency; 72.9%, Impeller out-diameter; 154mm, motor output; 55kw, design pressure; 1.0MPaG. The test facilities were designed for verification test of hydraulic performance suitable for pump performance test, homologous test, NPSH test(cavitation), cost down test and pressure pulsation test of inlet and outlet ports. Test tank was designed with testing capacity enabling up to 2000m{sup 3}/h and design pressure 1.0MPaG. Auxiliary pump was designed with centrifugal pump having capacity; 1100m{sup 3}/h, total head; 42.0m, motor output; 190kw

  10. ENVIRONMENTAL TECHNOLOGY VERIFICATION: JOINT (NSF-EPA) VERIFICATION STATEMENT AND REPORT: TRITON SYSTEMS, LLC SOLID BOWL CENTRIFUGE, MODEL TS-5000

    Science.gov (United States)

    Verification testing of the Triton Systems, LLC Solid Bowl Centrifuge Model TS-5000 (TS-5000) was conducted at the Lake Wheeler Road Field Laboratory Swine Educational Unit in Raleigh, North Carolina. The TS-5000 was 48" in diameter and 30" deep, with a bowl capacity of 16 ft3. ...

  11. Software Testing and Verification in Climate Model Development

    Science.gov (United States)

    Clune, Thomas L.; Rood, RIchard B.

    2011-01-01

    Over the past 30 years most climate models have grown from relatively simple representations of a few atmospheric processes to a complex multi-disciplinary system. Computer infrastructure over that period has gone from punch card mainframes to modem parallel clusters. Model implementations have become complex, brittle, and increasingly difficult to extend and maintain. Existing verification processes for model implementations rely almost exclusively upon some combination of detailed analysis of output from full climate simulations and system-level regression tests. In additional to being quite costly in terms of developer time and computing resources, these testing methodologies are limited in terms of the types of defects that can be detected, isolated and diagnosed. Mitigating these weaknesses of coarse-grained testing with finer-grained "unit" tests has been perceived as cumbersome and counter-productive. In the commercial software sector, recent advances in tools and methodology have led to a renaissance for systematic fine-grained testing. We discuss the availability of analogous tools for scientific software and examine benefits that similar testing methodologies could bring to climate modeling software. We describe the unique challenges faced when testing complex numerical algorithms and suggest techniques to minimize and/or eliminate the difficulties.

  12. Technology and testing.

    Science.gov (United States)

    Quellmalz, Edys S; Pellegrino, James W

    2009-01-02

    Large-scale testing of educational outcomes benefits already from technological applications that address logistics such as development, administration, and scoring of tests, as well as reporting of results. Innovative applications of technology also provide rich, authentic tasks that challenge the sorts of integrated knowledge, critical thinking, and problem solving seldom well addressed in paper-based tests. Such tasks can be used on both large-scale and classroom-based assessments. Balanced assessment systems can be developed that integrate curriculum-embedded, benchmark, and summative assessments across classroom, district, state, national, and international levels. We discuss here the potential of technology to launch a new era of integrated, learning-centered assessment systems.

  13. High Performance Electrical Modeling and Simulation Verification Test Suite - Tier I; TOPICAL

    International Nuclear Information System (INIS)

    SCHELLS, REGINA L.; BOGDAN, CAROLYN W.; WIX, STEVEN D.

    2001-01-01

    This document describes the High Performance Electrical Modeling and Simulation (HPEMS) Global Verification Test Suite (VERTS). The VERTS is a regression test suite used for verification of the electrical circuit simulation codes currently being developed by the HPEMS code development team. This document contains descriptions of the Tier I test cases

  14. CATS Deliverable 5.1 : CATS verification of test matrix and protocol

    NARCIS (Netherlands)

    Uittenbogaard, J.; Camp, O.M.G.C. op den; Montfort, S. van

    2016-01-01

    This report summarizes the work conducted within work package (WP) 5 "Verification of test matrix and protocol" of the Cyclist AEB testing system (CATS) project. It describes the verification process of the draft CATS test matrix resulting from WP1 and WP2, and the feasibility of meeting

  15. Recent trends on Software Verification and Validation Testing

    International Nuclear Information System (INIS)

    Kim, Hyungtae; Jeong, Choongheui

    2013-01-01

    Verification and Validation (V and V) include the analysis, evaluation, review, inspection, assessment, and testing of products. Especially testing is an important method to verify and validate software. Software V and V testing covers test planning to execution. IEEE Std. 1012 is a standard on the software V and V. Recently, IEEE Std. 1012-2012 was published. This standard is a major revision to IEEE Std. 1012-2004 which defines only software V and V. It expands the scope of the V and V processes to include system and hardware as well as software. This standard describes the scope of V and V testing according to integrity level. In addition, independent V and V requirement related to software V and V testing in IEEE 7-4.3.2-2010 have been revised. This paper provides a recent trend of software V and V testing by reviewing of IEEE Std. 1012-2012 and IEEE 7-4.3.2-2010. There are no major changes of software V and V testing activities and tasks in IEEE 1012-2012 compared with IEEE 1012-2004. But the positions on the responsibility to perform software V and V testing are changed. In addition IEEE 7-4.3.2-2010 newly describes the positions on responsibility to perform Software V and V Testing. However, the positions of these standards on the V and V testing are different. For integrity level 3 and 4, IEEE 1012-2012 basically requires that V and V organization shall conduct all of V and V testing tasks such as test plan, test design, test case, and test procedure except test execution. If V and V testing is conducted by not V and V but another organization, the results of that testing shall be analyzed by the V and V organization. For safety-related software, IEEE 7-4.3.2-2010 requires that test procedures and reports shall be independently verified by the alternate organization regardless of who writes the procedures and/or conducts the tests

  16. Development of requirements tracking and verification technology for the NPP software

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Chul Hwan; Kim, Jang Yeol; Lee, Jang Soo; Song, Soon Ja; Lee, Dong Young; Kwon, Kee Choon

    1998-12-30

    Searched and analyzed the technology of requirements engineering in the areas of aerospace and defense industry, medical industry and nuclear industry. Summarized the status of tools for the software design and requirements management. Analyzed the software design methodology for the safety software of NPP. Development of the design requirements for the requirements tracking and verification system. Development of the background technology to design the prototype tool for the requirements tracking and verification.

  17. Development of requirements tracking and verification technology for the NPP software

    International Nuclear Information System (INIS)

    Jung, Chul Hwan; Kim, Jang Yeol; Lee, Jang Soo; Song, Soon Ja; Lee, Dong Young; Kwon, Kee Choon

    1998-01-01

    Searched and analyzed the technology of requirements engineering in the areas of aerospace and defense industry, medical industry and nuclear industry. Summarized the status of tools for the software design and requirements management. Analyzed the software design methodology for the safety software of NPP. Development of the design requirements for the requirements tracking and verification system. Development of the background technology to design the prototype tool for the requirements tracking and verification

  18. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, JCH FUEL SOLUTIONS, INC., JCH ENVIRO AUTOMATED FUEL CLEANING AND MAINTENANCE SYSTEM

    Science.gov (United States)

    The verification testing was conducted at the Cl facility in North Las Vegas, NV, on July 17 and 18, 2001. During this period, engine emissions, fuel consumption, and fuel quality were evaluated with contaminated and cleaned fuel.To facilitate this verification, JCH repre...

  19. Sandia technology. Volume 13, number 2 Special issue: verification of arms control treaties

    International Nuclear Information System (INIS)

    1989-01-01

    Nuclear deterrence, a cornerstone of US national security policy, has helped prevent global conflict for over 40 years. The DOE and DoD share responsibility for this vital part of national security. The US will continue to rely on nuclear deterrence for the foreseeable future. In the late 1950s, Sandia developed satellite-borne nuclear burst detection systems to support the treaty banning atmospheric nuclear tests. This activity has continued to expand and diversify. When the Non-Proliferation Treaty was ratified in 1970, we began to develop technologies to protect nuclear materials from falling into unauthorized hands. This program grew and now includes systems for monitoring the movement and storage of nuclear materials, detecting tampering, and transmiting sensitive data securely. In the late 1970s, negotiations to further limit underground nuclear testing were being actively pursued. In less than 18 months, we fielded the National Seismic Station, an unattended observatory for in-country monitoring of nuclear tests. In the mid-l980s, arms-control interest shifted to facility monitoring and on-site inspection. Our Technical On-site Inspection Facility is the national test bed for perimeter and portal monitoring technology and the prototype for the inspection portal that was recently installed in the USSR under the Intermediate-Range Nuclear Forces accord. The articles in the special issue of Sundiu Technology describe some of our current contributions to verification technology. This work supports the US policy to seek realistic arms control agreements while maintaining our national security.

  20. Expose : procedure and results of the joint experiment verification tests

    Science.gov (United States)

    Panitz, C.; Rettberg, P.; Horneck, G.; Rabbow, E.; Baglioni, P.

    The International Space Station will carry the EXPOSE facility accommodated at the universal workplace URM-D located outside the Russian Service Module. The launch will be affected in 2005 and it is planned to stay in space for 1.5 years. The tray like structure will accomodate 2 chemical and 6 biological PI-experiments or experiment systems of the ROSE (Response of Organisms to Space Environment) consortium. EXPOSE will support long-term in situ studies of microbes in artificial meteorites, as well as of microbial communities from special ecological niches, such as endolithic and evaporitic ecosystems. The either vented or sealed experiment pockets will be covered by an optical filter system to control intensity and spectral range of solar UV irradiation. Control of sun exposure will be achieved by the use of individual shutters. To test the compatibility of the different biological systems and their adaptation to the opportunities and constraints of space conditions a profound ground support program has been developed. The procedure and first results of this joint Experiment Verification Tests (EVT) will be presented. The results will be essential for the success of the EXPOSE mission and have been done in parallel with the development and construction of the final hardware design of the facility. The results of the mission will contribute to the understanding of the organic chemistry processes in space, the biological adaptation strategies to extreme conditions, e.g. on early Earth and Mars, and the distribution of life beyond its planet of origin.

  1. Enhanced verification test suite for physics simulation codes

    Energy Technology Data Exchange (ETDEWEB)

    Kamm, James R.; Brock, Jerry S.; Brandon, Scott T.; Cotrell, David L.; Johnson, Bryan; Knupp, Patrick; Rider, William J.; Trucano, Timothy G.; Weirs, V. Gregory

    2008-09-01

    This document discusses problems with which to augment, in quantity and in quality, the existing tri-laboratory suite of verification problems used by Los Alamos National Laboratory (LANL), Lawrence Livermore National Laboratory (LLNL), and Sandia National Laboratories (SNL). The purpose of verification analysis is demonstrate whether the numerical results of the discretization algorithms in physics and engineering simulation codes provide correct solutions of the corresponding continuum equations.

  2. Field test for treatment verification of an in-situ enhanced bioremediation study

    International Nuclear Information System (INIS)

    Taur, C.K.; Chang, S.C.

    1995-01-01

    Due to a leakage from a 12-inch pressurized diesel steel pipe four years ago, an area of approximately 30,000 square meters was contaminated. A pilot study applying the technology of in-situ enhanced bioremediation was conducted. In the study, a field test kit and on-site monitoring equipment were applied for site characterization and treatment verification. Physically, the enhanced bioremediation study consisted of an air extraction and air supply system, and a nutrition supply network. Certain consistent sampling methodology was employed. Progress was verified by daily monitoring and monthly verification. The objective of this study was to evaluate the capabilities of indigenous microorganisms to biodegrade the petroleum hydrocarbons with provision of oxygen and nutrients. Nine extraction wells and eight air sparging wells were installed. The air sparging wells injected the air into geoformation and the extraction wells provided the underground air circulation. The soil samples were obtained monthly for treatment verification by a Minuteman drilling machine with 2.5-foot-long hollow-stem augers. The samples were analyzed on site for TPH-diesel concentration by a field test kit manufactured by HNU-Hanby, Houston, Texas. The analytical results from the field test kit were compared with the results from an environmental laboratory. The TVPH concentrations of the air extracted from the vadose zone by a vacuum blower and the extraction wells were routinely monitored by a Foxboro FID and Cosmos XP-311A combustible air detector. The daily monitoring of TVPH concentrations provided the reliable data for assessing the remedial progress

  3. Manual and automation testing and verification of TEQ [ECI PROPIRETRY

    Science.gov (United States)

    Abhichandra, Ravi; Jasmine Pemeena Priyadarsini, M.

    2017-11-01

    The telecommunication industry has progressed from 1G to 4G and now 5G is gaining prominence. Given the pace of this abrupt transformation, technological obsolescence is becoming a serious issue to deal with. Adding to this fact is that the execution of each technology requires ample investment into network, infrastructure, development etc. As a result, the industry is becoming more dynamic and strategy oriented. It requires professionals who not only can understand technology but also can evaluate the same from a business perspective. The “Information Revolution” and the dramatic advances in telecommunications technology, which has made this possible, currently drive the global economy in large part. As wireless networks become more advanced and far-reaching, we are redefining the notion of connectivity and the possibilities of communications technology. In this paper I test and verify the optical cards and automate this test procedure by using a new in-house technology “TEQ” developed by ECI TELECOM which uses one the optical cards itself to pump traffic of 100gbps.

  4. National Accounts Energy Alliance : Field test and verification of CHP components and systems

    Energy Technology Data Exchange (ETDEWEB)

    Sweetser, R. [Exergy Partners Corporation, Herndon, VA (United States)

    2003-07-01

    Exergy is a consulting firm which specializes in capitalizing on opportunities that result from the nexus of utility deregulation and global climate change in both the construction and energy industries. The firm offers assistance in technical business and market planning, product development and high impact marketing and technology transfer programs. The author discussed National Accounts Energy Alliance (NAEA) program on distributed energy resources (DER) and identified some advantageous areas such as homeland security (less possible terrorist targets to be protected), food safety (protection of food supply and delivery system), reliability, power quality, energy density, grid congestion and energy price. In the future, an essential role in moderating energy prices for commercial buildings will probably be played by distributed generation (DG) and combined heat and power (CHP). The technical merits of these technologies is being investigated by national accounts and utilities partnering with non-profit organizations, the United States Department of Energy (US DOE), state governments and industry. In that light, in 2001 an Alliance program was developed, which allows investors to broaden their knowledge from the application and verification of Advanced Energy Technologies. This program was the result of a synergy between the American Gas Foundation and the Gas Technology Institute (GTI), and it assists investors with their strategic planning. It was proven that a customer-led Energy Technology Test and Verification Program (TA and VP) could be cost-effective and successful. The NAEA activities in five locations were reviewed and discussed. They were: (1) Russell Development, Portland, Oregon; (2) A and P-Waldbaums, Hauppage, New York; (3) HEB, Southern, Texas; (4) Cinemark, Plano, Texas; and McDonald's, Tampa, Florida. 4 tabs., figs.

  5. DKIST enclosure modeling and verification during factory assembly and testing

    Science.gov (United States)

    Larrakoetxea, Ibon; McBride, William; Marshall, Heather K.; Murga, Gaizka

    2014-08-01

    The Daniel K. Inouye Solar Telescope (DKIST, formerly the Advanced Technology Solar Telescope, ATST) is unique as, apart from protecting the telescope and its instrumentation from the weather, it holds the entrance aperture stop and is required to position it with millimeter-level accuracy. The compliance of the Enclosure design with the requirements, as of Final Design Review in January 2012, was supported by mathematical models and other analyses which included structural and mechanical analyses (FEA), control models, ventilation analysis (CFD), thermal models, reliability analysis, etc. During the Enclosure Factory Assembly and Testing the compliance with the requirements has been verified using the real hardware and the models created during the design phase have been revisited. The tests performed during shutter mechanism subsystem (crawler test stand) functional and endurance testing (completed summer 2013) and two comprehensive system-level factory acceptance testing campaigns (FAT#1 in December 2013 and FAT#2 in March 2014) included functional and performance tests on all mechanisms, off-normal mode tests, mechanism wobble tests, creation of the Enclosure pointing map, control system tests, and vibration tests. The comparison of the assumptions used during the design phase with the properties measured during the test campaign provides an interesting reference for future projects.

  6. Project W-030 flammable gas verification monitoring test

    International Nuclear Information System (INIS)

    BARKER, S.A.

    1999-01-01

    This document describes the verification monitoring campaign used to document the ability of the new ventilation system to mitigate flammable gas accumulation under steady state tank conditions. This document reports the results of the monitoring campaign. The ventilation system configuration, process data, and data analysis are presented

  7. The JPSS Ground Project Algorithm Verification, Test and Evaluation System

    Science.gov (United States)

    Vicente, G. A.; Jain, P.; Chander, G.; Nguyen, V. T.; Dixon, V.

    2016-12-01

    The Government Resource for Algorithm Verification, Independent Test, and Evaluation (GRAVITE) is an operational system that provides services to the Suomi National Polar-orbiting Partnership (S-NPP) Mission. It is also a unique environment for Calibration/Validation (Cal/Val) and Data Quality Assessment (DQA) of the Join Polar Satellite System (JPSS) mission data products. GRAVITE provides a fast and direct access to the data and products created by the Interface Data Processing Segment (IDPS), the NASA/NOAA operational system that converts Raw Data Records (RDR's) generated by sensors on the S-NPP into calibrated geo-located Sensor Data Records (SDR's) and generates Mission Unique Products (MUPS). It also facilitates algorithm investigation, integration, checkouts and tuning, instrument and product calibration and data quality support, monitoring and data/products distribution. GRAVITE is the portal for the latest S-NPP and JPSS baselined Processing Coefficient Tables (PCT's) and Look-Up-Tables (LUT's) and hosts a number DQA offline tools that takes advantage of the proximity to the near-real time data flows. It also contains a set of automated and ad-hoc Cal/Val tools used for algorithm analysis and updates, including an instance of the IDPS called GRAVITE Algorithm Development Area (G-ADA), that has the latest installation of the IDPS algorithms running in an identical software and hardware platforms. Two other important GRAVITE component are the Investigator-led Processing System (IPS) and the Investigator Computing Facility (ICF). The IPS is a dedicated environment where authorized users run automated scripts called Product Generation Executables (PGE's) to support Cal/Val and data quality assurance offline. This data-rich and data-driven service holds its own distribution system and allows operators to retrieve science data products. The ICF is a workspace where users can share computing applications and resources and have full access to libraries and

  8. Alpha radioactivity measurement technology with ionized air type measurement. Applicability evaluation to verification of the clearance level

    International Nuclear Information System (INIS)

    Mita, Yutaka; Matsumura, Toshihiro; Yokoyama, Kaoru; Sugitsue, Noritake

    2008-10-01

    The purpose of this test is to evaluate the applicability of the clearance level measuring system by Ionized Air Type Measurement after decontaminated by sulfuric acid sample. In Ningyo-toge Environmental Engineering Center. The equipment and radioactive waste which were contaminated with uranium are generated so much in future dismantling stage. In our plan, some of equipments and radioactive waste are contaminated to a clearance level, and cut down on decommission and disposal expense. This plan needs the alpha-rays measurement technology of the very low level. We think that ionized Air transfer measurement technology is promising as of clearance verification technology. The ionized Air transfer measurement technology applied to the Ionized Air Type Measurement can measure plan radioactivity of a very low level. Moreover, as compared with a direct survey, there is the merit which can be measured in a short time. However ionized Air transfer measurement technology is new technology. Therefore, there is almost no measurement track record. Furthermore, the date about the influence of a background, a detection limit, measurement performance, and reliability is insufficient. So, this measurement test estimated applicability as clearance level verification of an Ionized Air Type Measurement. (author)

  9. The development of advanced instrumentation and control technology -The development of verification and validation technology for instrumentation and control in NPPs-

    International Nuclear Information System (INIS)

    Kwon, Kee Choon; Ham, Chang Sik; Lee, Byung Sun; Kim, Jung Taek; Park, Won Man; Park, Jae Chang; Lee, Jang Soo; Um, Heung Sub; Kim, Jang Yul; Ryoo, Chan Hoh; Joo, Jae Yoon; Song, Soon Ja

    1995-07-01

    We collected and analyzed the domestic/international codes, standards and guidelines to develop high reliable software verification and validation methodology which is satisfied to our real situation. The three major parts of work are performed that is the construction of the frame for high reliable software development environment, establishment of high reliable software development methodology and study for the basic technology related to safety-critical software. These three parts are tightly coupled each other to achieve self-reliable software verification and validation technology for digital I and C in NPPs. The configuration of hardware and software are partly performed using requirements which is developed in first stage for the development of I and C test facility. In hardware part, expanded interface using VXI bus and driving software is completed. The main program for math, modelling and supervisor program for instructions are developed. 27 figs, 22 tabs, 69 refs. (Author)

  10. The development of advanced instrumentation and control technology -The development of verification and validation technology for instrumentation and control in NPPs-

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Kee Choon; Ham, Chang Sik; Lee, Byung Sun; Kim, Jung Taek; Park, Won Man; Park, Jae Chang; Lee, Jang Soo; Um, Heung Sub; Kim, Jang Yul; Ryoo, Chan Hoh; Joo, Jae Yoon; Song, Soon Ja [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-07-01

    We collected and analyzed the domestic/international codes, standards and guidelines to develop high reliable software verification and validation methodology which is satisfied to our real situation. The three major parts of work are performed that is the construction of the frame for high reliable software development environment, establishment of high reliable software development methodology and study for the basic technology related to safety-critical software. These three parts are tightly coupled each other to achieve self-reliable software verification and validation technology for digital I and C in NPPs. The configuration of hardware and software are partly performed using requirements which is developed in first stage for the development of I and C test facility. In hardware part, expanded interface using VXI bus and driving software is completed. The main program for math, modelling and supervisor program for instructions are developed. 27 figs, 22 tabs, 69 refs. (Author).

  11. Quality Assurance in Environmental Technology Verification (ETV): Analysis and Impact on the EU ETV Pilot Programme Performance

    Science.gov (United States)

    Molenda, Michał; Ratman-Kłosińska, Izabela

    2018-03-01

    Many innovative environmental technologies never reach the market because they are new and cannot demonstrate a successful track record of previous applications. This fact is a serious obstacle on their way to the market. Lack of credible data on the performance of a technology causes mistrust of investors in innovations, especially from public sector, who seek effective solutions however without compromising the technical and financial risks associated with their implementation. Environmental technology verification (ETV) offers a credible, robust and transparent process that results in a third party confirmation of the claims made by the providers about the performance of the novel environmental technologies. Verifications of performance are supported by high quality, independent test data. In that way ETV as a tool helps establish vendor credibility and buyer confidence. Several countries across the world have implemented ETV in the form of national or regional programmes. ETV in the European Union was implemented as a voluntary scheme if a form of a pilot programme. The European Commission launched the Environmental Technology Pilot Programme of the European Union (EU ETV) in 2011. The paper describes the European model of ETV set up and put to operation under the Pilot Programme of Environmental Technologies Verification of the European Union. The goal, objectives, technological scope, involved entities are presented. An attempt has been made to summarise the results of the EU ETV scheme performance available for the period of 2012 when the programme has become fully operational until the first half of 2016. The study was aimed at analysing the overall organisation and efficiency of the EU ETV Pilot Programme. The study was based on the analysis of the documents the operation of the EU ETV system. For this purpose, a relevant statistical analysis of the data on the performance of the EU ETV system provided by the European Commission was carried out.

  12. Achievement report on developing superconductor power applied technologies in fiscal 1999 (2). Research and development of superconductor wire materials, research and development of superconductor power generators, research of total systems, research and development of freezing systems, and verification tests; 1999 nendo chodendo denryoku oyo gijutsu kaihatsu seika hokokusho. 2. Chodendo senzai no kenkyu kaihatsu / chodendo hatsudenki no kenkyu kaihatsu / total system no kenkyu / reito system no kenkyu kaihatsu / jissho shiken

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    With an objective to achieve higher efficiency, higher density, and higher stability in power systems, research and development has been performed on superconductor power generators. This paper summarizes the achievements thereof in fiscal 1999. A verification test was given on the rotor of an ultra high speed responding generator. In a sudden short circuit test using the different phase charging method, no anomalies were found such as quench generation and vibration changes, wherein the healthiness of the generator was verified. In the VVVF actuation test, knowledge was acquired on the actuation method when the ultra high speed responding generator is applied to a combined cycle plant. After the verification test has been completed, the disassembly inspections such as visual check and non-destructive test were performed. With regard to the vacuum leakage found in the rotor under very low temperatures, the causes were presumed and the countermeasures were discussed by observing the weld structures. In the design research, the conception design on the 200-MW pilot generator was reviewed by reflecting the results of the verification tests on the model generator. At the same time, trial design was made on a 600-MW target generator. In summarizing the overall research achievements, the achievements and evaluations were summarized on technological issues that have been allotted to each research member. (NEDO)

  13. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, BAGHOUSE FILTRATION PRODUCTS, TETRATEC PTFE PRODUCTS, TETRATEX 6212 FILTER SAMPLE

    Science.gov (United States)

    Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) Verification Center. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of the size of those particles equal to and smalle...

  14. ENVIORNMENTAL TECHNOLOGY VERIFICATION REPORT: ANEST IWATA CORPORATION LPH400-LV HVLP SPRAY GUN

    Science.gov (United States)

    This Enviornmental Technology Verification reports on the characteristics of a paint spray gun. The research showed that the spray gun provided absolute and relative increases in transfer efficiency over the base line and provided a reduction in the use of paint.

  15. Warm Water Oxidation Verification - Scoping and Stirred Reactor Tests

    Energy Technology Data Exchange (ETDEWEB)

    Braley, Jenifer C.; Sinkov, Sergey I.; Delegard, Calvin H.; Schmidt, Andrew J.

    2011-06-15

    Scoping tests to evaluate the effects of agitation and pH adjustment on simulant sludge agglomeration and uranium metal oxidation at {approx}95 C were performed under Test Instructions(a,b) and as per sections 5.1 and 5.2 of this Test Plan prepared by AREVA. (c) The thermal testing occurred during the week of October 4-9, 2010. The results are reported here. For this testing, two uranium-containing simulant sludge types were evaluated: (1) a full uranium-containing K West (KW) container sludge simulant consisting of nine predominant sludge components; (2) a 50:50 uranium-mole basis mixture of uraninite [U(IV)] and metaschoepite [U(VI)]. This scoping study was conducted in support of the Sludge Treatment Project (STP) Phase 2 technology evaluation for the treatment and packaging of K-Basin sludge. The STP is managed by CH2M Hill Plateau Remediation Company (CHPRC) for the U.S. Department of Energy. Warm water ({approx}95 C) oxidation of sludge, followed by immobilization, has been proposed by AREVA and is one of the alternative flowsheets being considered to convert uranium metal to UO{sub 2} and eliminate H{sub 2} generation during final sludge disposition. Preliminary assessments of warm water oxidation have been conducted, and several issues have been identified that can best be evaluated through laboratory testing. The scoping evaluation documented here was specifically focused on the issue of the potential formation of high strength sludge agglomerates at the proposed 95 C process operating temperature. Prior hydrothermal tests conducted at 185 C produced significant physiochemical changes to genuine sludge, including the formation of monolithic concretions/agglomerates that exhibited shear strengths in excess of 100 kPa (Delegard et al. 2007).

  16. Warm Water Oxidation Verification - Scoping and Stirred Reactor Tests

    International Nuclear Information System (INIS)

    Braley, Jenifer C.; Sinkov, Sergey I.; Delegard, Calvin H.; Schmidt, Andrew J.

    2011-01-01

    Scoping tests to evaluate the effects of agitation and pH adjustment on simulant sludge agglomeration and uranium metal oxidation at ∼95 C were performed under Test Instructions(a,b) and as per sections 5.1 and 5.2 of this Test Plan prepared by AREVA. (c) The thermal testing occurred during the week of October 4-9, 2010. The results are reported here. For this testing, two uranium-containing simulant sludge types were evaluated: (1) a full uranium-containing K West (KW) container sludge simulant consisting of nine predominant sludge components; (2) a 50:50 uranium-mole basis mixture of uraninite (U(IV)) and metaschoepite (U(VI)). This scoping study was conducted in support of the Sludge Treatment Project (STP) Phase 2 technology evaluation for the treatment and packaging of K-Basin sludge. The STP is managed by CH2M Hill Plateau Remediation Company (CHPRC) for the U.S. Department of Energy. Warm water (∼95 C) oxidation of sludge, followed by immobilization, has been proposed by AREVA and is one of the alternative flowsheets being considered to convert uranium metal to UO 2 and eliminate H 2 generation during final sludge disposition. Preliminary assessments of warm water oxidation have been conducted, and several issues have been identified that can best be evaluated through laboratory testing. The scoping evaluation documented here was specifically focused on the issue of the potential formation of high strength sludge agglomerates at the proposed 95 C process operating temperature. Prior hydrothermal tests conducted at 185 C produced significant physiochemical changes to genuine sludge, including the formation of monolithic concretions/agglomerates that exhibited shear strengths in excess of 100 kPa (Delegard et al. 2007).

  17. GENERIC VERIFICATION PROTOCOL FOR DETERMINATION OF EMISSIONS REDUCTIONS FROM SELECTIVE CATALYTIC REDUCTIONS CONTROL TECHNOLOGIES FOR HIGHWAY, NONROAD, AND STATIONARY USE DIESEL ENGINES

    Science.gov (United States)

    The protocol describes the Environmental Technology Verification (ETV) Program's considerations and requirements for verification of emissions reduction provided by selective catalytic reduction (SCR) technologies. The basis of the ETV will be comparison of the emissions and perf...

  18. Environmental Technology Verification: Biological Inactivation Efficiency by HVAC In-Duct Ultraviolet Light Systems--American Ultraviolet Corporation, DC24-6-120 [EPA600etv08005

    Science.gov (United States)

    The Air Pollution Control Technology Verification Center (APCT Center) is operated by RTI International (RTI), in cooperation with EPA's National Risk Management Research Laboratory. The APCT Center conducts verifications of technologies that clean air in ventilation systems, inc...

  19. Integrating software testing and run-time checking in an assertion verification framework

    OpenAIRE

    Mera, E.; López García, Pedro; Hermenegildo, Manuel V.

    2009-01-01

    We have designed and implemented a framework that unifies unit testing and run-time verification (as well as static verification and static debugging). A key contribution of our approach is that a unified assertion language is used for all of these tasks. We first propose methods for compiling runtime checks for (parts of) assertions which cannot be verified at compile-time via program transformation. This transformation allows checking preconditions and postconditions, including conditional...

  20. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: DEVILBISS JGHV-531-46FF HVLP SPRAY GUN

    Science.gov (United States)

    This report presents the results of the verification test of the DeVilbiss JGHV-531-46FF high-volume, low-pressure pressure-feed spray gun, hereafter referred to as the DeVilbiss JGHV, which is designed for use in industrial finishing. The test coating chosen by ITW Industrial Fi...

  1. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, HVLP COATING EQUIPMENT, SHARPE MANUFACTURING COMPANY PLATINUM 2012 HVLP SPRAY GUN

    Science.gov (United States)

    This report presents the results of the verification test of the Sharpe Platinum 2013 high-volume, low-pressure gravity-feed spray gun, hereafter referred to as the Sharpe Platinum, which is designed for use in automotive refinishing. The test coating chosen by Sharpe Manufacturi...

  2. Update on Monitoring Technologies for International Safeguards and Fissile Material Verification

    International Nuclear Information System (INIS)

    Croessmann, C. Dennis; Glidewell, Don D.; Mangan, Dennis L.; Smathers, Douglas C.

    1999-01-01

    Monitoring technologies are playing an increasingly important part in international safeguards and fissile material verification. The developments reduce the time an inspector must spend at a site while assuring continuity of knowledge. Monitoring technologies' continued development has produced new seal systems and integrated video surveillance advances under consideration for Trilateral Initiative use. This paper will present recent developments for monitoring systems at Embalse, Argentina, VNHEF, Sarov, Russian, and Savannah River Site, Aiken, South Carolina

  3. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT - PHYSICAL REMOVAL OF MICROBIOLOGICAL AND PARTICULATE CONTAMINANTS IN DRINKING WATER : SEPARMATIC™ FLUID SYSTEMS DIATOMACEOUS EARTH PRESSURE TYPE FILTER SYSTEM MODEL 12P-2

    Science.gov (United States)

    The verification test of the SeparmaticTM DE Pressure Type Filter System Model 12P-2 was conducted at the UNH Water Treatment Technology Assistance Center (WTTAC) in Durham, New Hampshire. The source water was finished water from the Arthur Rollins Treatment Plant that was pretr...

  4. Independent Verification Survey Report For Zone 1 Of The East Tennessee Technology Park In Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    King, David A.

    2012-01-01

    Oak Ridge Associated Universities (ORAU) conducted in-process inspections and independent verification (IV) surveys in support of DOE's remedial efforts in Zone 1 of East Tennessee Technology Park (ETTP) in Oak Ridge, Tennessee. Inspections concluded that the remediation contractor's soil removal and survey objectives were satisfied and the dynamic verification strategy (DVS) was implemented as designed. Independent verification (IV) activities included gamma walkover surveys and soil sample collection/analysis over multiple exposure units (EUs)

  5. Test/QA plan for the verification testing of alternative or reformulated liquid fuels, fuel additives, fuel emulsions, and lubricants for highway and nonroad use heavy-duty diesel engines

    Science.gov (United States)

    This Environmental Technology Verification Program test/QA plan for heavy-duty diesel engine testing at the Southwest Research Institute’s Department of Emissions Research describes how the Federal Test Procedure (FTP), as listed in 40 CFR Part 86 for highway engines and 40 CFR P...

  6. Stirling cryocooler test results and design model verification

    International Nuclear Information System (INIS)

    Shimko, M.A.; Stacy, W.D.; McCormick, J.A.

    1990-01-01

    This paper reports on progress in developing a long-life Stirling cycle cryocooler for space borne applications. It presents the results from tests on a preliminary breadboard version of the cryocooler used to demonstrate the feasibility of the technology and to validate the regenerator design code used in its development. This machine achieved a cold-end temperature of 65 K while carrying a 1/2 Watt cooling load. The basic machine is a double-acting, flexure-bearing, split Stirling design with linear electromagnetic drives for the expander and compressors. Flat metal diaphragms replace pistons for both sweeping and sealing the machine working volumes. In addition, the double-acting expander couples to a laminar-channel counterflow recuperative heat exchanger for regeneration. A PC compatible design code was developed for this design approach that calculates regenerator loss including heat transfer irreversibilities, pressure drop, and axial conduction in the regenerator walls

  7. Field test plan: Buried waste technologies, Fiscal Year 1995

    International Nuclear Information System (INIS)

    Heard, R.E.; Hyde, R.A.; Engleman, V.S.; Evans, J.D.; Jackson, T.W.

    1995-06-01

    The US Department of Energy, Office of Technology Development, supports the applied research, development, demonstration, testing, and evaluation of a suite of advanced technologies that, when integrated with commercially available baseline technologies, form a comprehensive remediation system for the effective and efficient remediation of buried waste. The Fiscal Year 1995 effort is to deploy and test multiple technologies from four functional areas of buried waste remediation: site characterization, waste characterization, retrieval, and treatment. This document is the basic operational planning document for the deployment and testing of the technologies that support the field testing in Fiscal Year 1995. Discussed in this document are the scope of the tests; purpose and objective of the tests; organization and responsibilities; contingency plans; sequence of activities; sampling and data collection; document control; analytical methods; data reduction, validation, and verification; quality assurance; equipment and instruments; facilities and utilities; health and safety; residuals management; and regulatory management

  8. Verification Test Report for CFAST 3.1.6

    International Nuclear Information System (INIS)

    Vincent, A.M. III

    2002-01-01

    Fire is a significant hazard in most facilities that handle radioactive materials. The severity of fire varies with room arrangement, combustible loading, ventilation and protective system response. The complexity of even simple situations can be unwieldy to solve by hand calculations. Thus, computer simulation of the fire severity has become an important tool in characterizing fire risk. The Savannah River Site (SRS), a Department of Energy facility, has been using the Consolidated Model of Fire Growth and Smoke Transport (CFAST) software to complete such deterministic evaluations to better characterize the nuclear facility fire severity. To fully utilize CFAST at SRS it is necessary to demonstrate that CFAST produces valid analytic solutions over its range of use. This report describes the primary verification exercise that is required to establish that CFAST, and its user interface program FAST, produce valid analytic solutions. This verification exercise may be used to check the fu nctionality of FAST and as a training tool to familiarize users with the software. In addition, the report consolidates the lessons learned by the SRS staff in using FAST and CFAST as fire modeling tools

  9. Verification Test Report for CFAST 3.1.6; TOPICAL

    International Nuclear Information System (INIS)

    Vincent, A.M. III

    2002-01-01

    Fire is a significant hazard in most facilities that handle radioactive materials. The severity of fire varies with room arrangement, combustible loading, ventilation and protective system response. The complexity of even simple situations can be unwieldy to solve by hand calculations. Thus, computer simulation of the fire severity has become an important tool in characterizing fire risk. The Savannah River Site (SRS), a Department of Energy facility, has been using the Consolidated Model of Fire Growth and Smoke Transport (CFAST) software to complete such deterministic evaluations to better characterize the nuclear facility fire severity. To fully utilize CFAST at SRS it is necessary to demonstrate that CFAST produces valid analytic solutions over its range of use. This report describes the primary verification exercise that is required to establish that CFAST, and its user interface program FAST, produce valid analytic solutions. This verification exercise may be used to check the fu nctionality of FAST and as a training tool to familiarize users with the software. In addition, the report consolidates the lessons learned by the SRS staff in using FAST and CFAST as fire modeling tools

  10. Report on results for fiscal 1997 on development of superconducting electric power application technology. Pt. 2. R and D of superconducting wire, R and D of superconducting generator, studies on total system, R and D of refrigeration system, and verification test; 1997 nendo chodendo denryoku oyo gijutsu kaihatsu seika hokokusho. Chodendo senzai no kenkyu kaihatsu, chodendo hatsudenki no kenkyu kaihatsu, total system no kenkyu, reito system no kenkyu kaihatsu, jissho shiken

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-09-01

    This report refers, continuously to the Part 1, to the in-situ verification test of the slow-response type model machine rotor and to the review of the conceptual design of the pilot machine. On the basis of the R and D results of various element technology/partial models obtained before the previous fiscal year, the design, manufacturing and factory test had been conducted for a 70,000kW class slow-response type model machine rotor. This year, an in-situ verification test was performed to complete the test of all planned test items. Using the technological results obtained in the design, manufacturing and test of the 70,000kW class model machine, the conceptual design is being reviewed of the 200,000kW class pilot machine. In the aspect of the functional design, accurate grasping of the thermal load is essential for the purpose of attaining a large capacity for a superconducting generator, as a part of which a thermal load analytical method was planned to be established for a torque tube heat exchanger. The reasonableness of the analysis was verified through a comparison with the factory test result of the 70,000kW class slow-response type rotor, indicating good agreement between the calculation result and the actual measurement, and enabling the result to be obtained that explains dependency of the thermal load on the number of revolution. (NEDO)

  11. Environmental Testing Campaign and Verification of Satellite Deimos-2 at INTA

    Science.gov (United States)

    Hernandez, Daniel; Vazquez, Mercedes; Anon, Manuel; Olivo, Esperanza; Gallego, Pablo; Morillo, Pablo; Parra, Javier; Capraro; Luengo, Mar; Garcia, Beatriz; Villacorta, Pablo

    2014-06-01

    In this paper the environmental test campaign and verification of the DEIMOS-2 (DM2) satellite will be presented and described. DM2 will be ready for launch in 2014.Firstly, a short description of the satellite is presented, including its physical characteristics and intended optical performances. DEIMOS-2 is a LEO satellite for earth observation that will provide high resolution imaging services for agriculture, civil protection, environmental issues, disasters monitoring, climate change, urban planning, cartography, security and intelligence.Then, the verification and test campaign carried out on the SM and FM models at INTA is described; including Mechanical test for the SM and Climatic, Mechanical and Electromagnetic Compatibility tests for the FM. In addition, this paper includes Centre of Gravity and Moment of Inertia measurements for both models, and other verification activities carried out in order to ensure satellite's health during launch and its in orbit performance.

  12. RAPID FREEFORM SHEET METAL FORMING: TECHNOLOGY DEVELOPMENT AND SYSTEM VERIFICATION

    Energy Technology Data Exchange (ETDEWEB)

    Kiridena, Vijitha [Ford Scientific Research Lab., Dearborn, MI (United States); Verma, Ravi [Boeing Research and Technology (BR& T), Seattle, WA (United States); Gutowski, Timothy [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Roth, John [Pennsylvania State Univ., University Park, PA (United States)

    2018-03-31

    The objective of this project is to develop a transformational RApid Freeform sheet metal Forming Technology (RAFFT) in an industrial environment, which has the potential to increase manufacturing energy efficiency up to ten times, at a fraction of the cost of conventional technologies. The RAFFT technology is a flexible and energy-efficient process that eliminates the need for having geometry-specific forming dies. The innovation lies in the idea of using the energy resource at the local deformation area which provides greater formability, process control, and process flexibility relative to traditional methods. Double-Sided Incremental Forming (DSIF), the core technology in RAFFT, is a new concept for sheet metal forming. A blank sheet is clamped around its periphery and gradually deformed into a complex 3D freeform part by two strategically aligned stylus-type tools that follow a pre-described toolpath. The two tools, one on each side of the blank, can form a part with sharp features for both concave and convex shapes. Since deformation happens locally, the forming force at any instant is significantly decreased when compared to traditional methods. The key advantages of DSIF are its high process flexibility, high energy-efficiency, low capital investment, and the elimination of the need for massive amounts of die casting and machining. Additionally, the enhanced formability and process flexibility of DSIF can open up design spaces and result in greater weight savings.

  13. Verification and Uncertainty Reduction of Amchitka Underground Nuclear Testing Models

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed Hassan; Jenny Chapman

    2006-02-01

    The modeling of Amchitka underground nuclear tests conducted in 2002 is verified and uncertainty in model input parameters, as well as predictions, has been reduced using newly collected data obtained by the summer 2004 field expedition of CRESP. Newly collected data that pertain to the groundwater model include magnetotelluric (MT) surveys conducted on the island to determine the subsurface salinity and porosity structure of the subsurface, and bathymetric surveys to determine the bathymetric maps of the areas offshore from the Long Shot and Cannikin Sites. Analysis and interpretation of the MT data yielded information on the location of the transition zone, and porosity profiles showing porosity values decaying with depth. These new data sets are used to verify the original model in terms of model parameters, model structure, and model output verification. In addition, by using the new data along with the existing data (chemistry and head data), the uncertainty in model input and output is decreased by conditioning on all the available data. A Markov Chain Monte Carlo (MCMC) approach is adapted for developing new input parameter distributions conditioned on prior knowledge and new data. The MCMC approach is a form of Bayesian conditioning that is constructed in such a way that it produces samples of the model parameters that eventually converge to a stationary posterior distribution. The Bayesian MCMC approach enhances probabilistic assessment. Instead of simply propagating uncertainty forward from input parameters into model predictions (i.e., traditional Monte Carlo approach), MCMC propagates uncertainty backward from data onto parameters, and then forward from parameters into predictions. Comparisons between new data and the original model, and conditioning on all available data using MCMC method, yield the following results and conclusions: (1) Model structure is verified at Long Shot and Cannikin where the high-resolution bathymetric data collected by CRESP

  14. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: IN-DRAIN TREATMENT DEVICE. HYDRO INTERNATIONAL UP-FLO™ FILTER

    Science.gov (United States)

    Verification testing of the Hydro International Up-Flo™ Filter with one filter module and CPZ Mix™ filter media was conducted at the Penn State Harrisburg Environmental Engineering Laboratory in Middletown, Pennsylvania. The Up-Flo™ Filter is designed as a passive, modular filtr...

  15. An overview of CTBT verification technologies and status of IMS networks

    International Nuclear Information System (INIS)

    Basham, P.

    2002-01-01

    The CTBT history is described in brief. Nuclear test environments and verification regime are presented with illustrations. Geographical location of seismic, hydroacoustic, infrasound and radionuclide monitoring networks are indicated on globe maps. Benefits of the International Monitoring System (IMS) to host countries are listed

  16. Software Verification and Validation Test Report for the HEPA filter Differential Pressure Fan Interlock System

    International Nuclear Information System (INIS)

    ERMI, A.M.

    2000-01-01

    The HEPA Filter Differential Pressure Fan Interlock System PLC ladder logic software was tested using a Software Verification and Validation (VandV) Test Plan as required by the ''Computer Software Quality Assurance Requirements''. The purpose of his document is to report on the results of the software qualification

  17. Two important safety-related verification tests in the design of Qinshan NPP 600 MWe reactor

    International Nuclear Information System (INIS)

    Li Pengzhou; Li Tianyong; Yu Danping; Sun Lei

    2005-01-01

    This paper summarizes two most important verification tests performed in the design of reactor of Qinshan NPP Phase II: seismic qualification test of control rod drive line (CRDL), flow-induced vibration test of reactor internals both in 1:5 scaled model and on-site measurement during heat function testing (HFT). Both qualification tests proved that the structural design of the reactor has large safety margin. (authors)

  18. Development of a Torque Sensor-Based Test Bed for Attitude Control System Verification and Validation

    Science.gov (United States)

    2017-12-30

    AFRL-RV-PS- AFRL-RV-PS- TR-2018-0008 TR-2018-0008 DEVELOPMENT OF A TORQUE SENSOR- BASED TEST BED FOR ATTITUDE CONTROL SYSTEM VERIFICATION AND...Sensor-Based Test Bed for Attitude Control System Verification & Validation 5a. CONTRACT NUMBER FA9453-15-1-0315 5b. GRANT NUMBER 5c. PROGRAM ELEMENT...NUMBER 62601F 6. AUTHOR(S) Norman Fitz-Coy 5d. PROJECT NUMBER 4846 5e. TASK NUMBER PPM00015968 5f. WORK UNIT NUMBER EF125135 7. PERFORMING

  19. Standard practice for verification of constant amplitude dynamic forces in an axial fatigue testing system

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This practice covers procedures for the dynamic verification of cyclic force amplitude control or measurement accuracy during constant amplitude testing in an axial fatigue testing system. It is based on the premise that force verification can be done with the use of a strain gaged elastic element. Use of this practice gives assurance that the accuracies of forces applied by the machine or dynamic force readings from the test machine, at the time of the test, after any user applied correction factors, fall within the limits recommended in Section 9. It does not address static accuracy which must first be addressed using Practices E 4 or equivalent. 1.2 Verification is specific to a particular test machine configuration and specimen. This standard is recommended to be used for each configuration of testing machine and specimen. Where dynamic correction factors are to be applied to test machine force readings in order to meet the accuracy recommended in Section 9, the verification is also specific to the c...

  20. Achievement report on developing superconductor power applied technologies in fiscal 1999 (1). Research and development of superconductor wire materials, research and development of superconductor power generators, research of total systems, research and development of freezing systems, and verification tests; 1999 nendo chodendo denryoku oyo gijutsu kaihatsu seika hokokusho. 1. Chodendo senzai no kenkyu kaihatsu / chodendo hatsudenki no kenkyu kaihatsu / total system no kenkyu / reito system no kenkyu kaihatsu / jissho shiken

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    With an objective to achieve higher efficiency, higher density, and higher stability in power systems, research and development has been performed on superconductor power applied technologies. This paper summarizes the achievements thereof in fiscal 1999. In research and development of the superconductor wire materials, decrease in loss and increase in capacity of the conductors were progressed for the Nb{sub 3}Sn wire material, whereas its mechanical properties and stability were evaluated. In research and development of the superconductor generators, an ultra high speed responding generator was verified of its healthiness in a sudden short circuit test. A linkage test with an operating 77-kV system was performed, wherein verification was given that the superconductor generator can be operated stably against various disturbances. In research and development of the freezing systems, an improved system was structured, which achieved operation of 11,390 hours in a single system as a result of the high reliability of the oil-free structure. In the verification tests, the ultra high speed responding model generator was connect to the freezing system to give such tests as load test, onerous test, actuation test by using the M-G system, and 77-kV system linkage test. The functions, reliability, and durability of the system were verified, and different data were acquired. (NEDO)

  1. Verification test calculations for the Source Term Code Package

    International Nuclear Information System (INIS)

    Denning, R.S.; Wooton, R.O.; Alexander, C.A.; Curtis, L.A.; Cybulskis, P.; Gieseke, J.A.; Jordan, H.; Lee, K.W.; Nicolosi, S.L.

    1986-07-01

    The purpose of this report is to demonstrate the reasonableness of the Source Term Code Package (STCP) results. Hand calculations have been performed spanning a wide variety of phenomena within the context of a single accident sequence, a loss of all ac power with late containment failure, in the Peach Bottom (BWR) plant, and compared with STCP results. The report identifies some of the limitations of the hand calculation effort. The processes involved in a core meltdown accident are complex and coupled. Hand calculations by their nature must deal with gross simplifications of these processes. Their greatest strength is as an indicator that a computer code contains an error, for example that it doesn't satisfy basic conservation laws, rather than in showing the analysis accurately represents reality. Hand calculations are an important element of verification but they do not satisfy the need for code validation. The code validation program for the STCP is a separate effort. In general the hand calculation results show that models used in the STCP codes (e.g., MARCH, TRAP-MELT, VANESA) obey basic conservation laws and produce reasonable results. The degree of agreement and significance of the comparisons differ among the models evaluated. 20 figs., 26 tabs

  2. Eddy current testing using digital technology

    International Nuclear Information System (INIS)

    Houseman, H.E.; Lamb, L.T.; Kitson, B.

    1985-01-01

    Eddy current inspection techniques have been used extensively in industry as an accepted method of non-destructive testing. The application of this technology has proven invaluable for both the control of product quality during the manufacturing process as well as the verification of material integrity throughout the life of a given component. One of the major areas in the power industry where eddy current techniques have been used is for the inspection of installed tubing in various heat exchangers including the steam generators of pressurized water reactor (PWR) nuclear steam supply systems. As increased emphasis is placed upon the operability and safety of these components, test instrumentation has been advanced to improve the efficiency and reliability of inservice inspections. At the same time, plant owners along with manufacturers and inspection service vendors are developing analytical tools for assessing the inspection results. One of the techniques that offers significant potential has been made possible by recent advances in digital technology. The application of digital techniques to the eddy current method offers not only a means to improve the test instrumentation but also an environment whereby other facets of the inservice inspection effort can be enchanced

  3. Design verification of the CANFLEX fuel bundle - quality assurance requirements for mechanical flow testing

    International Nuclear Information System (INIS)

    Alavi, P.; Oldaker, I.E.; Chung, C.H.; Suk, H.C.

    1997-01-01

    As part of the design verification program for the new fuel bundle, a series of out-reactor tests was conducted on the CANFLEX 43-element fuel bundle design. These tests simulated current CANDU 6 reactor normal operating conditions of flow, temperature and pressure. This paper describes the Quality Assurance (QA) Program implemented for the tests that were run at the testing laboratories of Atomic Energy of Canada Limited (AECL) and Korea Atomic energy Research Institute (KAERI). (author)

  4. SNS Target Test Facility for remote handling design and verification

    International Nuclear Information System (INIS)

    Spampinato, P.T.; Graves, V.B.; Schrock, S.L.

    1998-01-01

    The Target Test Facility will be a full-scale prototype of the Spallation Neutron Source Target Station. It will be used to demonstrate remote handling operations on various components of the mercury flow loop and for thermal/hydraulic testing. This paper describes the remote handling aspects of the Target Test Facility. Since the facility will contain approximately 1 cubic meter of mercury for the thermal/hydraulic tests, an enclosure will also be constructed that matches the actual Target Test Cell

  5. The US National Resources Defense Council/Soviet Academy of Sciences Nuclear Test Ban Verification Project

    International Nuclear Information System (INIS)

    Cochran, T.B.

    1989-01-01

    The first week in September 1987 was an extraordinary one for arms control verification. As part of the co-operative Test Ban Verification Project of the Natural Resources Defense Council (NRDC) and the Soviet Academy of Sciences, fourteen American scientists from the Scripps Institution of Oceanography (at the University of California- San Diego), University of Nevada-Reno and the University of Colorado went to the region of the Soviet's principal nuclear test site near Semipalatinsk. Together with their Soviet counterparts from the Institute of Physics of the Earth (IPE) in Moscow, they fired off three large chemical explosions. The purpose of these explosions was to demonstrate the sensitivity of the three seismic stations surrounding the test site, to study the efficiency with which high-frequency seismic waves propagate in the region, and to study differences between chemical explosions, nuclear explosions and earthquakes in order more firmly to establish procedures for verification of a nuclear test ban. This paper presents a review of the results of these experiments, an update on the status of the joint project, and a review of the significance of high frequency seismic data to test ban verification

  6. Use of Radio Frequency Identification (RFID) for Tracking Hazardous Waste Shipments Across International Borders -Test/QA Plan

    Science.gov (United States)

    The Environmental Technology Verification (ETV) – Environmental and Sustainable Technology Evaluations (ESTE) Program conducts third-party verification testing of commercially available technologies that may accomplish environmental program management goals. In this verification...

  7. New Approaches and New Technologies for the Verification of Nuclear Disarmament

    International Nuclear Information System (INIS)

    Keir, David

    2013-01-01

    ESARDA’s New Approaches/Novel Technologies Working group has recently begun to take a great interest in technology for use in arms control verification, in parallel with a focus on Nuclear Safeguards technology. A topic-based meeting of members of the NA/NT Subgroup was hosted at Joint Research Centre (JRC), ITU-Nuclear Security Unit in Ispra (Italy), to further explore the technical issues and opportunities presented by the need for new approaches and technologies in a future verified nuclear weapons dismantlement regime. Nuclear warheads must contain radioactive material and, by their nature, gamma rays and neutrons are likely to penetrate to the outside of the warhead casing and even metal containers. Therefore radiation signatures should be detectable by appropriate pieces of equipment. For this reason, researchers in the field of technical verification of nuclear warhead dismantlement have studied and developed technologies for Non-Destructive Assay (NDA). This paper presents a generic dismantlement pathway for verified nuclear warhead dismantlement, based on the scenario employed by the UK-Norway initiative for their exercise in 2008/9. Using this as a framework the types of measurement challenge likely to be presented to a verifying inspector are discussed. The problem of intrusiveness of measurements in relation to the issue of proliferative release of classified information about the warhead attributes is discussed and the concept of ‘information barriers is introduced as a possible solution to this issue. A list of candidate technologies for use in verification activities, with or without information barriers is then presented and, since most of these are new or novel approaches to the issue, an already-established system for classifying them – in terms of state of development and complexity of use in this context – is proposed. Finally, the concept of capturing this information as a library of ‘data sheets’, designed for periodic review as

  8. Report on results for fiscal 1997 on development of superconducting electric power application technology. Pt. 1. R and D of superconducting wire, R and D of superconducting generator, studies on total system, R and D of refrigeration system, and verification test; 1997 nendo chodendo denryoku oyo gijutsu kaihatsu seika hokokusho. 1. Chodendo senzai no kenkyu kaihatsu, chodendo hatsudenki no kenkyu kaihatsu, total system no kenkyu, reito system no kenkyu kaihatsu, jissho shiken

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-09-01

    This report explains the outline as Part 1. In fiscal 1997, the 10th year of the project, a multi cylindrical rotary model for which an in-situ verification test was finished was brought back to the plant and dismantled for examination, while the in-situ verification test of a slow-response type model machine rotor was conducted in combination with a refrigeration system. In addition, in the research of AC wire materials and oxide based materials, studies were made with a purpose of high characterization and long wire materialization. In the metallic materials, a 10kANbTi conductor was developed while, in oxide-based materials, research was done on performance improvement and wire materialization based on various synthesizing methods. The manufacturing, factory test and in-situ text were conducted for a 70,000kW model machine with the purpose of R and D of a 200,000kW class pilot machine. Examination was made on the test method of the 70,000kW class model machine, operation technology of a superconducting generation system, and the effect of introducing the superconducting generator into a power system. In the conventional refrigeration system, a single unit test was carried out for the liquefaction, liquid storing capacity, etc., of the system. The 70,000kW class model machine was put through a test for confirming the general operation including the refrigeration system. (NEDO)

  9. Development and verification of a reciprocating test rig designed for investigation of piston ring tribology

    DEFF Research Database (Denmark)

    Pedersen, Michael Torben; Imran, Tajammal; Klit, Peder

    2009-01-01

    This paper describes the development and verification of a reciprocating test rig, which was designed to study the piston ring tribology. A crank mechanism is used to generate a reciprocating motion for a moving plate, which acts as the liner. A stationary block acting as the ring package is loaded......, which is suitable for the study of piston ring tribology....

  10. Verification tests for remote controlled inspection system in nuclear power plants

    International Nuclear Information System (INIS)

    Kohno, Tadaaki

    1986-01-01

    Following the increase of nuclear power plants, the total radiation exposure dose accompanying inspection and maintenance works tended to increase. Japan Power Engineering and Inspection Corp. carried out the verification test of a practical power reactor automatic inspection system from November, 1981, to March, 1986, and in this report, the state of having carried out this verification test is described. The objects of the verification test were the equipment which is urgently required for reducing radiation exposure dose, the possibility of realization of which is high, and which is important for ensuring the safety and reliability of plants, that is, an automatic ultrasonic flaw detector for the welded parts of bend pipes, an automatic disassembling and inspection system for control rod driving mechanism, a fuel automatic inspection system, and automatic decontaminating equipments for steam generator water chambers, primary system crud and radioactive gas in coolant. The results of the verification test of these equipments were judged as satisfactory, therefore, the application to actual plants is possible. (Kako, I.)

  11. 9 CFR 381.94 - Contamination with Microorganisms; process control verification criteria and testing; pathogen...

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Contamination with Microorganisms... § 381.94 Contamination with Microorganisms; process control verification criteria and testing; pathogen... maintaining process controls sufficient to prevent fecal contamination. FSIS shall take further action as...

  12. General-Purpose Heat Source development: Safety Verification Test Program. Bullet/fragment test series

    Energy Technology Data Exchange (ETDEWEB)

    George, T.G.; Tate, R.E.; Axler, K.M.

    1985-05-01

    The radioisotope thermoelectric generator (RTG) that will provide power for space missions contains 18 General-Purpose Heat Source (GPHS) modules. Each module contains four /sup 238/PuO/sub 2/-fueled clads and generates 250 W/sub (t)/. Because a launch-pad or post-launch explosion is always possible, we need to determine the ability of GPHS fueled clads within a module to survive fragment impact. The bullet/fragment test series, part of the Safety Verification Test Plan, was designed to provide information on clad response to impact by a compact, high-energy, aluminum-alloy fragment and to establish a threshold value of fragment energy required to breach the iridium cladding. Test results show that a velocity of 555 m/s (1820 ft/s) with an 18-g bullet is at or near the threshold value of fragment velocity that will cause a clad breach. Results also show that an exothermic Ir/Al reaction occurs if aluminum and hot iridium are in contact, a contact that is possible and most damaging to the clad within a narrow velocity range. The observed reactions between the iridium and the aluminum were studied in the laboratory and are reported in the Appendix.

  13. General-Purpose Heat Source Safety Verification Test program: Edge-on flyer plate tests

    International Nuclear Information System (INIS)

    George, T.G.

    1987-03-01

    The radioisotope thermoelectric generator (RTG) that will supply power for the Galileo and Ulysses space missions contains 18 General-Purpose Heat Source (GPHS) modules. The GPHS modules provide power by transmitting the heat of 238 Pu α-decay to an array of thermoelectric elements. Each module contains four 238 PuO 2 -fueled clads and generates 250 W(t). Because the possibility of a launch vehicle explosion always exists, and because such an explosion could generate a field of high-energy fragments, the fueled clads within each GPHS module must survive fragment impact. The edge-on flyer plate tests were included in the Safety Verification Test series to provide information on the module/clad response to the impact of high-energy plate fragments. The test results indicate that the edge-on impact of a 3.2-mm-thick, aluminum-alloy (2219-T87) plate traveling at 915 m/s causes the complete release of fuel from capsules contained within a bare GPHS module, and that the threshold velocity sufficient to cause the breach of a bare, simulant-fueled clad impacted by a 3.5-mm-thick, aluminum-alloy (5052-T0) plate is approximately 140 m/s

  14. Explosion overpressure test series: General-Purpose Heat Source development: Safety Verification Test program

    International Nuclear Information System (INIS)

    Cull, T.A.; George, T.G.; Pavone, D.

    1986-09-01

    The General-Purpose Heat Source (GPHS) is a modular, radioisotope heat source that will be used in radioisotope thermoelectric generators (RTGs) to supply electric power for space missions. The first two uses will be the NASA Galileo and the ESA Ulysses missions. The RTG for these missions will contain 18 GPHS modules, each of which contains four 238 PuO 2 -fueled clads and generates 250 W/sub (t)/. A series of Safety Verification Tests (SVTs) was conducted to assess the ability of the GPHS modules to contain the plutonia in accident environments. Because a launch pad or postlaunch explosion of the Space Transportation System vehicle (space shuttle) is a conceivable accident, the SVT plan included a series of tests that simulated the overpressure exposure the RTG and GPHS modules could experience in such an event. Results of these tests, in which we used depleted UO 2 as a fuel simulant, suggest that exposure to overpressures as high as 15.2 MPa (2200 psi), without subsequent impact, does not result in a release of fuel

  15. HDTS 2017.1 Testing and Verification Document

    Energy Technology Data Exchange (ETDEWEB)

    Whiteside, T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-12-01

    This report is a continuation of the series of Hunter Dose Tracking System (HDTS) Quality Assurance documents including (Foley and Powell, 2010; Dixon, 2012; Whiteside, 2017b). In this report we have created a suite of automated test cases and a system to analyze the results of those tests as well as documented the methodology to ensure the field system performs within specifications. The software test cases cover all of the functions and interactions of functions that are practical to test. With the developed framework, if software defects are discovered, it will be easy to create one or more test cases to reproduce the defect and ensure that code changes correct the defect.

  16. Verification methods for treaties limiting and banning nuclear tests

    International Nuclear Information System (INIS)

    Voloshin, N.P.

    1998-01-01

    Treaty on limitation of underground nuclear weapon tests and treaty on world banning of nuclear tests contribute to and accompany the process of nuclear disarmament. Test ban in three (Moscow treaty of 1963) as well as the Threshold Test Ban up to 1991 was controlled only with national means. But since 1991 nuclear test threshold of 150 kt has been measured with hydrodynamic and tele seismic methods and checked by the inspection. Distinctive feature of this control is that control is that it is bilateral. This conforms to Treaty on limitation of underground nuclear weapon tests signed by two countries - USA and USSR. The inspection at the place of tests requires monitoring of the test site of the party conducting a test and geological information of rock in the area of explosion. In the treaty of the World Nuclear Test Ban the following ways of international control are provided for: - seismologic measurements; - radionuclide measurements; - hydro-acoustics measurements; - infra-sound measurements; - inspection at the place of the tests conduction

  17. A review of technology for verification of waste removal from Hanford Underground Storage Tanks (WHC Issue 30)

    International Nuclear Information System (INIS)

    Thunborg, S.

    1994-09-01

    Remediation of waste from Underground Storage Tanks (UST) at the Hanford Waste storage sites will require removal of all waste to a nearly clean condition. Current requirements are 99% clean. In order to meet remediation legal requirements, a means to remotely verify that the waste has been removed to sufficient level is needed. This report discusses the requirements for verification and reviews major technologies available for inclusion in a verification system. The report presents two operational scenarios for verification of residual waste volume. Thickness verification technologies reviewed are Ultrasonic Sensors, Capacitance Type Sensors, Inductive Sensors, Ground Penetrating Radar, and Magnetometers. Of these technologies Inductive (Metal Detectors) and Ground Penetrating Radar appear to be the most suitable for use as waste thickness sensors

  18. Working Group 2: Future Directions for Safeguards and Verification, Technology, Research and Development

    International Nuclear Information System (INIS)

    Zykov, S.; Blair, D.

    2013-01-01

    For traditional safeguards it was recognized that the hardware presently available is, in general, addressing adequately fundamental IAEA needs, and that further developments should therefore focus mainly on improving efficiencies (i.e. increasing cost economies, reliability, maintainability and user-friendliness, keeping abreast of continual advancements in technologies and of the evolution of verification approaches). Specific technology areas that could benefit from further development include: -) Non-destructive measurement systems (NDA), in particular, gamma-spectroscopy and neutron counting techniques; -) Containment and surveillance tools, such as tamper indicating seals, video-surveillance, surface identification methods, etc.; -) Geophysical methods for design information verification (DIV) and safeguarding of geological repositories; and -) New tools and methods for real-time monitoring. Furthermore, the Working Group acknowledged that a 'building block' (or modular) approach should be adopted towards technology development, enabling equipment to be upgraded efficiently as technologies advance. Concerning non-traditional safeguards, in the area of satellite-based sensors, increased spatial resolution and broadened spectral range were identified as priorities. In the area of wide area surveillance, the development of LIDAR-like tools for atmospheric sensing was discussed from the perspective of both potential benefits and certain limitations. Recognizing the limitations imposed by the human brain in terms of information assessment and analysis, technologies are needed that will enable the more effective utilization of all information, regardless of its format and origin. The paper is followed by the slides of the presentation. (A.C.)

  19. HDTS 2017.0 Testing and verification document

    Energy Technology Data Exchange (ETDEWEB)

    Whiteside, Tad S. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-08-01

    This report is a continuation of the series of Hunter Dose Tracking System (HDTS) Quality Assurance documents including (Foley and Powell, 2010; Dixon, 2012). In this report we have created a suite of automated test cases and a system to analyze the results of those tests as well as documented the methodology to ensure the field system performs within specifications. The software test cases cover all of the functions and interactions of functions that are practical to test. With the developed framework, if software defects are discovered, it will be easy to create one or more test cases to reproduce the defect and ensure that code changes correct the defect. These tests con rm HDTS version 2017.0 performs according to its specifications and documentation and that its performance meets the needs of its users at the Savannah River Site.

  20. Small-scale fixed wing airplane software verification flight test

    Science.gov (United States)

    Miller, Natasha R.

    The increased demand for micro Unmanned Air Vehicles (UAV) driven by military requirements, commercial use, and academia is creating a need for the ability to quickly and accurately conduct low Reynolds Number aircraft design. There exist several open source software programs that are free or inexpensive that can be used for large scale aircraft design, but few software programs target the realm of low Reynolds Number flight. XFLR5 is an open source, free to download, software program that attempts to take into consideration viscous effects that occur at low Reynolds Number in airfoil design, 3D wing design, and 3D airplane design. An off the shelf, remote control airplane was used as a test bed to model in XFLR5 and then compared to flight test collected data. Flight test focused on the stability modes of the 3D plane, specifically the phugoid mode. Design and execution of the flight tests were accomplished for the RC airplane using methodology from full scale military airplane test procedures. Results from flight test were not conclusive in determining the accuracy of the XFLR5 software program. There were several sources of uncertainty that did not allow for a full analysis of the flight test results. An off the shelf drone autopilot was used as a data collection device for flight testing. The precision and accuracy of the autopilot is unknown. Potential future work should investigate flight test methods for small scale UAV flight.

  1. Shaking table test and verification of development of an ...

    Indian Academy of Sciences (India)

    A full-scale multiple degrees of freedom shaking table is tested toverify the energy dissipation of this proposed AIC, including test building without control, with passive control added involving various stiffness ratios and also with synchronic control added involving various stiffness ratios. Shock absorption of displacement ...

  2. Retrofit and verification test of a 30-cm ion thruster

    Science.gov (United States)

    Dulgeroff, C. R.; Poeschel, R. L.

    1980-01-01

    Twenty modifications were found to be necessary and were approved by design review. These design modifications were incorporated in the thruster documents (drawings and procedures) to define the J series thruster. Sixteen of the design revisions were implemented in a 900 series thruster by retrofit modification. A standardized set of test procedures was formulated, and the retrofit J series thruster design was verified by test. Some difficulty was observed with the modification to the ion optics assembly, but the overall effect of the design modification satisfies the design objectives. The thruster was tested over a wide range of operating parameters to demonstrate its capabilities.

  3. Sheath insulator final test report, TFE Verification Program

    International Nuclear Information System (INIS)

    1994-07-01

    The sheath insulator in a thermionic cell has two functions. First, the sheath insulator must electrically isolate the collector form the outer containment sheath tube that is in contact with the reactor liquid metal coolant. Second, The sheath insulator must provide for high uniform thermal conductance between the collector and the reactor coolant to remove away waste heat. The goals of the sheath insulator test program were to demonstrate that suitable ceramic materials and fabrication processes were available, and to validate the performance of the sheath insulator for TFE-VP requirements. This report discusses the objectives of the test program, fabrication development, ex-reactor test program, in-reactor test program, and the insulator seal specifications

  4. Sheath insulator final test report, TFE Verification Program

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-01

    The sheath insulator in a thermionic cell has two functions. First, the sheath insulator must electrically isolate the collector form the outer containment sheath tube that is in contact with the reactor liquid metal coolant. Second, The sheath insulator must provide for high uniform thermal conductance between the collector and the reactor coolant to remove away waste heat. The goals of the sheath insulator test program were to demonstrate that suitable ceramic materials and fabrication processes were available, and to validate the performance of the sheath insulator for TFE-VP requirements. This report discusses the objectives of the test program, fabrication development, ex-reactor test program, in-reactor test program, and the insulator seal specifications.

  5. TEST/QA PLAN FOR THE VERIFICATION TESTING OF ALTERNATIVES OR REFORMULATED LIQUID FUELS, FUEL ADDITIVES, FUEL EMULSONS, AND LUBRICANTS FOR HIGHWAY AND NONROAD USE HEAVY DUTY DIESEL ENGINES AND LIGHT DUTY GASOLINE ENGINES AND VEHICLES

    Science.gov (United States)

    The U.S. Environmental Protection Agency established the Environmental Technology Verification Program to accelerate the development and commercialization of improved environmental technology through third party verification and reporting of product performance. Research Triangl...

  6. Structure-dynamic model verification calculation of PWR 5 tests

    International Nuclear Information System (INIS)

    Engel, R.

    1980-02-01

    Within reactor safety research project RS 16 B of the German Federal Ministry of Research and Technology (BMFT), blowdown experiments are conducted at Battelle Institut e.V. Frankfurt/Main using a model reactor pressure vessel with a height of 11,2 m and internals corresponding to those in a PWR. In the present report the dynamic loading on the pressure vessel internals (upper perforated plate and barrel suspension) during the DWR 5 experiment are calculated by means of a vertical and horizontal dynamic model using the CESHOCK code. The equations of motion are resolved by direct integration. (orig./RW) [de

  7. Independent verification and validation testing of the FLASH computer code, Versiion 3.0

    International Nuclear Information System (INIS)

    Martian, P.; Chung, J.N.

    1992-06-01

    Independent testing of the FLASH computer code, Version 3.0, was conducted to determine if the code is ready for use in hydrological and environmental studies at various Department of Energy sites. This report describes the technical basis, approach, and results of this testing. Verification tests, and validation tests, were used to determine the operational status of the FLASH computer code. These tests were specifically designed to test: correctness of the FORTRAN coding, computational accuracy, and suitability to simulating actual hydrologic conditions. This testing was performed using a structured evaluation protocol which consisted of: blind testing, independent applications, and graduated difficulty of test cases. Both quantitative and qualitative testing was performed through evaluating relative root mean square values and graphical comparisons of the numerical, analytical, and experimental data. Four verification test were used to check the computational accuracy and correctness of the FORTRAN coding, and three validation tests were used to check the suitability to simulating actual conditions. These tests cases ranged in complexity from simple 1-D saturated flow to 2-D variably saturated problems. The verification tests showed excellent quantitative agreement between the FLASH results and analytical solutions. The validation tests showed good qualitative agreement with the experimental data. Based on the results of this testing, it was concluded that the FLASH code is a versatile and powerful two-dimensional analysis tool for fluid flow. In conclusion, all aspects of the code that were tested, except for the unit gradient bottom boundary condition, were found to be fully operational and ready for use in hydrological and environmental studies

  8. ENVIRONMENTAL TECHNOLOGY VERIFICATION: JOINT (NSF-EPA) VERIFICATION STATEMENT AND REPORT HYDRO COMPLIANCE MANAGEMENT, INC. HYDRO-KLEEN FILTRATION SYSTEM, 03/07/WQPC-SWP, SEPTEMBER 2003

    Science.gov (United States)

    Verification testing of the Hydro-Kleen(TM) Filtration System, a catch-basin filter designed to reduce hydrocarbon, sediment, and metals contamination from surface water flows, was conducted at NSF International in Ann Arbor, Michigan. A Hydro-Kleen(TM) system was fitted into a ...

  9. ENVIRONMENTAL TECHNOLOGY VERIFICATION: JOINT (NSF-EPA) VERIFICATION STATEMENT AND REPORT: BROME AGRI SALES, LTD., MAXIMIZER SEPARATOR, MODEL MAX 1016 - 03/01/WQPC-SWP

    Science.gov (United States)

    Verification testing of the Brome Agri Sales Ltd. Maximizer Separator, Model MAX 1016 (Maximizer) was conducted at the Lake Wheeler Road Field Laboratory Swine Educational Unit in Raleigh, North Carolina. The Maximizer is an inclined screen solids separator that can be used to s...

  10. Testing and verification of a novel single-channel IGBT driver circuit

    OpenAIRE

    Lukić, Milan; Ninković, Predrag

    2016-01-01

    This paper presents a novel single-channel IGBT driver circuit together with a procedure for testing and verification. It is based on a specialized integrated circuit with complete range of protective functions. Experiments are performed to test and verify its behaviour. Experimental results are presented in the form of oscilloscope recordings. It is concluded that the new driver circuit is compatible with modern IGBT transistors and power converter demands and that it can be applied in new d...

  11. Target Soil Impact Verification: Experimental Testing and Kayenta Constitutive Modeling.

    Energy Technology Data Exchange (ETDEWEB)

    Broome, Scott Thomas [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Flint, Gregory Mark [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Dewers, Thomas [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Newell, Pania [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-11-01

    This report details experimental testing and constitutive modeling of sandy soil deformation under quasi - static conditions. This is driven by the need to understand constitutive response of soil to target/component behavior upon impact . An experimental and constitutive modeling program was followed to determine elastic - plastic properties and a compressional failure envelope of dry soil . One hydrostatic, one unconfined compressive stress (UCS), nine axisymmetric compression (ACS) , and one uniaxial strain (US) test were conducted at room temperature . Elastic moduli, assuming isotropy, are determined from unload/reload loops and final unloading for all tests pre - failure and increase monotonically with mean stress. Very little modulus degradation was discernable from elastic results even when exposed to mean stresses above 200 MPa . The failure envelope and initial yield surface were determined from peak stresses and observed onset of plastic yielding from all test results. Soil elasto - plastic behavior is described using the Brannon et al. (2009) Kayenta constitutive model. As a validation exercise, the ACS - parameterized Kayenta model is used to predict response of the soil material under uniaxial strain loading. The resulting parameterized and validated Kayenta model is of high quality and suitable for modeling sandy soil deformation under a range of conditions, including that for impact prediction.

  12. EVA Development and Verification Testing at NASA's Neutral Buoyancy Laboratory

    Science.gov (United States)

    Jairala, Juniper C.; Durkin, Robert; Marak, Ralph J.; Sipila, Stepahnie A.; Ney, Zane A.; Parazynski, Scott E.; Thomason, Arthur H.

    2012-01-01

    As an early step in the preparation for future Extravehicular Activities (EVAs), astronauts perform neutral buoyancy testing to develop and verify EVA hardware and operations. Neutral buoyancy demonstrations at NASA Johnson Space Center's Sonny Carter Training Facility to date have primarily evaluated assembly and maintenance tasks associated with several elements of the International Space Station (ISS). With the retirement of the Shuttle, completion of ISS assembly, and introduction of commercial players for human transportation to space, evaluations at the Neutral Buoyancy Laboratory (NBL) will take on a new focus. Test objectives are selected for their criticality, lack of previous testing, or design changes that justify retesting. Assembly tasks investigated are performed using procedures developed by the flight hardware providers and the Mission Operations Directorate (MOD). Orbital Replacement Unit (ORU) maintenance tasks are performed using a more systematic set of procedures, EVA Concept of Operations for the International Space Station (JSC-33408), also developed by the MOD. This paper describes the requirements and process for performing a neutral buoyancy test, including typical hardware and support equipment requirements, personnel and administrative resource requirements, examples of ISS systems and operations that are evaluated, and typical operational objectives that are evaluated.

  13. Verification Test of Automated Robotic Assembly of Space Truss Structures

    Science.gov (United States)

    Rhodes, Marvin D.; Will, Ralph W.; Quach, Cuong C.

    1995-01-01

    A multidisciplinary program has been conducted at the Langley Research Center to develop operational procedures for supervised autonomous assembly of truss structures suitable for large-aperture antennas. The hardware and operations required to assemble a 102-member tetrahedral truss and attach 12 hexagonal panels were developed and evaluated. A brute-force automation approach was used to develop baseline assembly hardware and software techniques. However, as the system matured and operations were proven, upgrades were incorporated and assessed against the baseline test results. These upgrades included the use of distributed microprocessors to control dedicated end-effector operations, machine vision guidance for strut installation, and the use of an expert system-based executive-control program. This paper summarizes the developmental phases of the program, the results of several assembly tests, and a series of proposed enhancements. No problems that would preclude automated in-space assembly or truss structures have been encountered. The test system was developed at a breadboard level and continued development at an enhanced level is warranted.

  14. Design, analysis, and test verification of advanced encapsulation systems

    Science.gov (United States)

    Garcia, A.; Minning, C.

    1981-01-01

    Thermal, optical, structural, and electrical isolation analyses are decribed. Major factors in the design of terrestrial photovoltaic modules are discussed. Mechanical defects in the different layers of an encapsulation system, it was found, would strongly influence the minimum pottant thickness required for electrical isolation. Structural, optical, and electrical properties, a literature survey indicated, are hevily influenced by the presence of moisture. These items, identified as technology voids, are discussed. Analyses were based upon a 1.2 meter square module using 10.2 cm (4-inch) square cells placed 1.3 mm apart as shown in Figure 2-2. Sizing of the structural support member of a module was determined for a uniform, normal pressure load of 50 psf, corresponding to the pressure difference generated between the front and back surface of a module by a 100 mph wind. Thermal and optical calculations were performed for a wind velocity of 1 meter/sec parallel to the ground and for module tilt (relative to the local horizontal) of 37 deg. Placement of a module in a typical array field is illustrated.

  15. Design, analysis, and test verification of advanced encapsulation systems

    Science.gov (United States)

    Garcia, A.; Minning, C.

    1981-11-01

    Thermal, optical, structural, and electrical isolation analyses are decribed. Major factors in the design of terrestrial photovoltaic modules are discussed. Mechanical defects in the different layers of an encapsulation system, it was found, would strongly influence the minimum pottant thickness required for electrical isolation. Structural, optical, and electrical properties, a literature survey indicated, are hevily influenced by the presence of moisture. These items, identified as technology voids, are discussed. Analyses were based upon a 1.2 meter square module using 10.2 cm (4-inch) square cells placed 1.3 mm apart as shown in Figure 2-2. Sizing of the structural support member of a module was determined for a uniform, normal pressure load of 50 psf, corresponding to the pressure difference generated between the front and back surface of a module by a 100 mph wind. Thermal and optical calculations were performed for a wind velocity of 1 meter/sec parallel to the ground and for module tilt (relative to the local horizontal) of 37 deg. Placement of a module in a typical array field is illustrated.

  16. Research on database realization technology of seismic information system in CTBT verification

    International Nuclear Information System (INIS)

    Zheng Xuefeng; Shen Junyi; Zhang Huimin; Jing Ping; Sun Peng; Zheng Jiangling

    2005-01-01

    Developing CTBT verification technology has become the most important method that makes sure CTBT to be fulfilled conscientiously. The seismic analysis based on seismic information system (SIS) is playing an important rule in this field. Based on GIS, the SIS will be very sufficient and powerful in spatial analysis, topologic analysis and visualization. However, the critical issue to implement the whole system function depends on the performance of SIS DB. Based on the ArcSDE Geodatabase data model, not only have the spatial data and attribute data seamless integrated management been realized with RDBMS ORACLE really, but also the most functions of ORACLE have been reserved. (authors)

  17. CTBT verification-related technologies for peaceful purposes: the French experiences of international cooperation

    International Nuclear Information System (INIS)

    Massinon, B.

    1999-01-01

    The French experience concerning CTBT verification-related technologies for peaceful purposes as well a the international cooperation in this field are presented. Possible objectives and cooperation program needs are cited. French experience in international cooperation is related to seismology and seismic hazards in Bolivia, Madagascar, Nepal and Indonesia and is considered as very constructive, meaning that technical experience is developed, consistent scientific results are obtained, and a considerable yield to the CTBT task is achieved. Large scientific benefits are expected from the CTBTO

  18. Test ban treaty verification with regional data: a review

    International Nuclear Information System (INIS)

    Pomeroy, P.W.; Best, W.J.; McEvilly, T.V.

    1982-01-01

    This paper summarizes the use of regional (Δ ≤ 30 0 ) seismic data in a test ban context for detecting, locating, identifying, and determining the yield of underground nuclear explosions. In many areas of the world (Eastern North America, Africa, Eastern USSR), Lg is the largest amplitude wave recorded on standard seismograph systems and thus is the most appropriate phase for monitoring small magnitude events. Excellent location capability for near-regional events has been demonstrated at the Norwegian small aperture array (NORESS) using Lg and P waves. Lg and other regional phases may contain information on source depth, but such information has not been exploited to date. Fifteen classes of regional discriminants are listed. Most have been tested only on limited data, usually from one geographic region and only one or two recording stations. No systematic analyses have been done to determine the best individual discriminant or combination of them. Preliminary evaluation of the use of Lg for yield determination suggests that regional waves hold promise in this application. Theoretical studies have contributed significantly to the understanding of propagation characteristics of regional waves but further studies are required emphasizing modeling for realistic anisotropic sources. The major conclusion of this study is that a systematic and comparative evaluation of all the proposed regional discriminants is now required, utilizing a common data base derived from all present-day test sites. This evaluation would suggest the optimal discrimination procedure using regional waves, and would also define areas of needed research. Without such an integrated evaluation, it is still possible to speculate, using existing results, on the most promising regional discriminants

  19. Dynamics of railway bridges, analysis and verification by field tests

    Directory of Open Access Journals (Sweden)

    Andersson Andreas

    2015-01-01

    Full Text Available The following paper discusses different aspects of railway bridge dynamics, comprising analysis, modelling procedures and experimental testing. The importance of realistic models is discussed, especially regarding boundary conditions, load distribution and soil-structure interaction. Two theoretical case studies are presented, involving both deterministic and probabilistic assessment of a large number of railway bridges using simplified and computationally efficient models. A total of four experimental case studies are also introduced, illustrating different aspects and phenomena in bridge dynamics. The excitation consists of both ambient vibrations, train induced vibrations, free vibrations after train passages and controlled forced excitation.

  20. Verification test for radiation reduction effect and material integrity on PWR primary system by zinc injection

    Energy Technology Data Exchange (ETDEWEB)

    Kawakami, H.; Nagata, T.; Yamada, M. [Nuclear Power Engineering Corp. (Japan); Kasahara, K.; Tsuruta, T.; Nishimura, T. [Mitsubishi Heavy Industries, Ltd. (Japan); Ishigure, K. [Saitama Inst. of Tech. (Japan)

    2002-07-01

    Zinc injection is known to be an effective method for the reduction of radiation source in the primary water system of a PWR. There is a need to verify the effect of Zn injection operation on radiation source reduction and materials integrity of PWR primary circuit. In order to confirm the effectiveness of Zn injection, verification test as a national program sponsored by Ministry of Economy, Trade and Industry (METI) was started in 1995 for 7-year program, and will be finished by the end of March in 2002. This program consists of irradiation test and material integrity test. Irradiation test as an In-Pile-Test managed by AEAT Plc(UK) was performed using the LVR-15 reactor of NRI Rez in Check Republic. Furthermore, Out-of-Pile-Test using film adding unit was also performed to obtain supplemental data for In-Pile-Test at Takasago Engineering Laboratory of NUPEC. Material Integrity test was planned to perform constant load test, constant strain test and corrosion test at the same time using large scale Loop and slow strain extension rate testing (SSRT) at Takasago Engineering Laboratory of NUPEC. In this paper, the results of the verification test for Zinc program at present are discussed. (authors)

  1. Experimental Verification of an Instrument to Test Flooring Materials

    Science.gov (United States)

    Philip, Rony; Löfgren, Hans, Dr

    2018-02-01

    The focus of this work is to validate the fluid model with different flooring materials and the measurements of an instrument to test flooring materials and its force attenuating capabilities using mathematical models to describe the signature and coefficients of the floor. The main contribution of the present work focus on the development of a mathematical fluid model for floors. The aim of the thesis was to analyze, compare different floor materials and to study the linear dynamics of falling impacts on floors. The impact of the hammer during a fall is captured by an accelerometer and response is collected using a picoscope. The collected data was analyzed using matlab least square method which is coded as per the fluid model. The finding from this thesis showed that the fluid model works with more elastic model but it doesn’t work for rigid materials like wood. The importance of parameters like velocity, mass, energy loss and other coefficients of floor which influences the model during the impact of falling on floors were identified and a standardized testing method was set.

  2. BWR regional instability model and verification on ringhals-1 test

    International Nuclear Information System (INIS)

    Hotta, Akitoshi; Suzawa, Yojiro

    1996-01-01

    Regional instability is known as one type of the coupled neutronic-thermohydraulic phenomena of boiling water reactors (BWRs), where the thermohydraulic density wave propagation mechanism is predominant. Historically, it has been simulated by the three-dimensional time domain code in spite of its significant computing time. On the other hand, there have been proposals to apply the frequency domain models in regional instability considering the subcriticality of the higher neutronic mode. However, their application still remains in corewide instability mainly because of the lack of more detailed methodological and empirical studies. In this study, the current version of the frequency domain model was extended and verified based on actual core regional instability measurement data. The mathematical model LAPUR, the well-known frequency domain stability code, was reviewed from the standpoint of pure thermohydraulics and neutronic-thermohydraulic interaction mechanisms. Based on the ex-core loop test data, the original LAPUR mixed friction and local pressure loss model was modified, taking into account the different dynamic behavior of these two pressure-loss mechanisms. The perturbation term of the two-phase friction multiplier, which is the sum of the derivative of void fraction and subcool enthalpy, was adjusted theoretically. The adequacy of the instability evaluation system was verified based on the Ringhals unit 1 test data, which were supplied to participants of the Organization for Economic Cooperation and Development/Nuclear Energy Agency BWR Stability Benchmark Project

  3. Development and verification test of integral reactor major components

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. I.; Kim, Y. W.; Kim, J. H. and others

    1999-03-01

    The conceptual designs for SG, MCP, CEDM to be installed in the integral reactor SMART were developed. Three-dimensional CAD models for the major components were developed to visualize the design concepts. Once-through helical steam generator was conceptually designed for SMART. Canned motor pump was adopted in the conceptual design of MCP. Linear pulse motor type and ballscrew type CEDM, which have fine control capabilities were studied for adoption in SMART. In parallel with the structural design, the electro-magnetic design was performed for the sizing motors and electro-magnet. Prototypes for the CEDM and MCP sub-assemblies were developed and tested to verify the performance. The impeller design procedure and the computer program to analyze the dynamic characteristics of MCP rotor shaft were developed. The design concepts of SG, MCP, CEDM were also invetigated for the fabricability.

  4. Test and Verification of AES Used for Image Encryption

    Science.gov (United States)

    Zhang, Yong

    2018-03-01

    In this paper, an image encryption program based on AES in cipher block chaining mode was designed with C language. The encryption/decryption speed and security performance of AES based image cryptosystem were tested and used to compare the proposed cryptosystem with some existing image cryptosystems based on chaos. Simulation results show that AES can apply to image encryption, which refutes the widely accepted point of view that AES is not suitable for image encryption. This paper also suggests taking the speed of AES based image encryption as the speed benchmark of image encryption algorithms. And those image encryption algorithms whose speeds are lower than the benchmark should be discarded in practical communications.

  5. Development and verification test of integral reactor major components

    International Nuclear Information System (INIS)

    Kim, J. I.; Kim, Y. W.; Kim, J. H. and others

    1999-03-01

    The conceptual designs for SG, MCP, CEDM to be installed in the integral reactor SMART were developed. Three-dimensional CAD models for the major components were developed to visualize the design concepts. Once-through helical steam generator was conceptually designed for SMART. Canned motor pump was adopted in the conceptual design of MCP. Linear pulse motor type and ballscrew type CEDM, which have fine control capabilities were studied for adoption in SMART. In parallel with the structural design, the electro-magnetic design was performed for the sizing motors and electro-magnet. Prototypes for the CEDM and MCP sub-assemblies were developed and tested to verify the performance. The impeller design procedure and the computer program to analyze the dynamic characteristics of MCP rotor shaft were developed. The design concepts of SG, MCP, CEDM were also invetigated for the fabricability

  6. Shear Ram Verification Test Protocol (VTP) Best Practices

    Energy Technology Data Exchange (ETDEWEB)

    Lindley, Roy A. [Argonne National Lab. (ANL), Argonne, IL (United States); Braun, Joseph C. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2017-01-01

    A blowout preventer (BOP) is a critical component used on subsea oil and gas wells during drilling, completion, and workover operations on the U. S. outer continental shelf (OCS). The purpose of the BOP is to seal oil and gas wells, and in the case of an emergency well-control event, to prevent the uncontrolled release of hydrocarbons. One of the most important components of the BOP is the hydraulically operated blind shear ram (BSR) that shears drilling-related components, such as drill pipes, casings, tubings, and wire-related tools that may have been placed in the well. In addition to shearing these components, the BSR must form a seal to keep hydrocarbons within the well bore, even when under the highest well-fluid pressures expected. The purpose of this document is for Argonne National Laboratory (ANL) to provide an independent view, based on current regulations, and best practices for testing and confirming the operability and suitability of BSRs under realistic (or actual) well conditions.

  7. Finite Element Verification of Non-Homogeneous Strain and Stress Fields during Composite Material Testing

    DEFF Research Database (Denmark)

    Mikkelsen, Lars Pilgaard

    2015-01-01

    Uni-directional glass fiber reinforced polymers play a central role in the task increasing the length of wind turbines blades and thereby lowering the cost of energy from wind turbine installations. During this, optimizing the mechanical performance regarding material stiffness, compression...... strength and fatigue performance is essential. Nevertheless, testing composites includes some challenges regarding stiffness determination using conventional strain gauges and achieving correct material failure unaffected by the gripping region during fatigue testing. Challenges, which in the present study......, has been addressed using the finite element method. During this, a verification of experimental observations, a deeper understanding on the test coupon loading and thereby improved test methods has been achieved....

  8. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, SWINE WASTE ELECTRIC POWER AND HEAT PRODUCTION--CAPSTONE 30KW MICROTURBINE SYSTEM

    Science.gov (United States)

    Under EPA’s Environmental Technology Verification program, which provides objective and scientific third party analysis of new technology that can benefit the environment, a combined heat and power system was evaluated based on the Capstone 30kW Microturbine developed by Cain Ind...

  9. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: RESIDENTIAL ELECTRIC POWER GENERATION USING THE PLUG POWER SU1 FUEL CELL SYSTEM

    Science.gov (United States)

    The Environmental Technology Verification report discusses the technology and performance of the Plug Power SU1 Fuel Cell System manufactured by Plug Power. The SU1 is a proton exchange membrane fuel cell that requires hydrogen (H2) as fuel. H2 is generally not available, so the ...

  10. Testing Dialog-Verification of SIP Phones with Single-Message Denial-of-Service Attacks

    Science.gov (United States)

    Seedorf, Jan; Beckers, Kristian; Huici, Felipe

    The Session Initiation Protocol (SIP) is widely used for signaling in multimedia communications. However, many SIP implementations are still in their infancy and vulnerable to malicious messages. We investigate flaws in the SIP implementations of eight phones, showing that the deficient verification of SIP dialogs further aggravates the problem by making it easier for attacks to succeed. Our results show that the majority of the phones we tested are susceptible to these attacks.

  11. EQ3/6 software test and verification report 9/94

    International Nuclear Information System (INIS)

    Kishi, T.

    1996-02-01

    This document is the Software Test and Verification Report (STVR) for the EQ3/6 suite of codes as stipulated in the Individual Software Plan for Initial Qualification of EQ3/6 (ISP-NF-07, Revision 1, 11/25/92). The software codes, EQPT, EQ3NR, EQ6, and the software library EQLIB constitute the EQ3/6 software package. This software test and verification project for EQ3/6 was started under the requirements of the LLNL Yucca Mountain Project Software Quality Assurance Plan (SQAP), Revision 0, December 14, 1989, but QP 3.2, Revision 2, June 21, 1994 is now the operative controlling procedure. This is a ''V and V'' report in the language of QP 3.2, Revision 2. Because the author of this report does not have a background in geochemistry, other technical sources were consulted in order to acquire some familiarity with geochemisty, the terminology minology involved, and to review comparable computational methods especially, geochemical aqueous speciation-solubility calculations. The software for the EQ3/6 package consists of approximately 47,000 lines of FORTRAN77 source code and nine on platforms ranging from workstations to supercomputers. The physical control of EQ3/6 software package and documentation is on a SUN SPARC station. Walkthroughs of each principal software packages, EQPT, EQ3NR, and EQ6 were conducted in order to understand the computational procedures involved, to determine any commonality in procedures, and then to establish a plan for the test and verification of EQ3/6. It became evident that all three phases depended upon solving an n x n matrix by the Newton-Raphson Method. Thus, a great deal of emphasis on the test and verification of this procedure was carried out on the first code in the software package EQPT

  12. Surface coatings as xenon diffusion barriers on plastic scintillators : Improving Nuclear-Test-Ban Treaty verification

    OpenAIRE

    Bläckberg, Lisa

    2011-01-01

    This thesis investigates the ability of transparent surface coatings to reduce xenon diffusion into plastic scintillators. The motivation for the work is improved radioxenon monitoring equipment, used with in the framework of the verification regime of the Comprehensive Nuclear-Test-Ban Treaty. A large part of the equipment used in this context incorporates plastic scintillators which are in direct contact with the radioactive gas to be detected. One problem with such setup is that radioxenon...

  13. Probabilistic Requirements (Partial) Verification Methods Best Practices Improvement. Variables Acceptance Sampling Calculators: Empirical Testing. Volume 2

    Science.gov (United States)

    Johnson, Kenneth L.; White, K. Preston, Jr.

    2012-01-01

    The NASA Engineering and Safety Center was requested to improve on the Best Practices document produced for the NESC assessment, Verification of Probabilistic Requirements for the Constellation Program, by giving a recommended procedure for using acceptance sampling by variables techniques as an alternative to the potentially resource-intensive acceptance sampling by attributes method given in the document. In this paper, the results of empirical tests intended to assess the accuracy of acceptance sampling plan calculators implemented for six variable distributions are presented.

  14. EQ3/6 software test and verification report 9/94

    Energy Technology Data Exchange (ETDEWEB)

    Kishi, T.

    1996-02-01

    This document is the Software Test and Verification Report (STVR) for the EQ3/6 suite of codes as stipulated in the Individual Software Plan for Initial Qualification of EQ3/6 (ISP-NF-07, Revision 1, 11/25/92). The software codes, EQPT, EQ3NR, EQ6, and the software library EQLIB constitute the EQ3/6 software package. This software test and verification project for EQ3/6 was started under the requirements of the LLNL Yucca Mountain Project Software Quality Assurance Plan (SQAP), Revision 0, December 14, 1989, but QP 3.2, Revision 2, June 21, 1994 is now the operative controlling procedure. This is a ``V and V`` report in the language of QP 3.2, Revision 2. Because the author of this report does not have a background in geochemistry, other technical sources were consulted in order to acquire some familiarity with geochemisty, the terminology minology involved, and to review comparable computational methods especially, geochemical aqueous speciation-solubility calculations. The software for the EQ3/6 package consists of approximately 47,000 lines of FORTRAN77 source code and nine on platforms ranging from workstations to supercomputers. The physical control of EQ3/6 software package and documentation is on a SUN SPARC station. Walkthroughs of each principal software packages, EQPT, EQ3NR, and EQ6 were conducted in order to understand the computational procedures involved, to determine any commonality in procedures, and then to establish a plan for the test and verification of EQ3/6. It became evident that all three phases depended upon solving an n x n matrix by the Newton-Raphson Method. Thus, a great deal of emphasis on the test and verification of this procedure was carried out on the first code in the software package EQPT.

  15. Comprehensive Nuclear-Test-Ban Treaty: Science and Technology 2011 (S and T2011). Announcement

    International Nuclear Information System (INIS)

    2011-01-01

    To build and strengthen its relationship with the broader science community in support of the Treaty, the Preparatory Commission for the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) invites the community to a scientific conference CTBT: Science and Technology 2011 (S and T 2011), to be held from 8 to 10 June 2011 at the Hofburg Palace in Vienna, Austria. The conference goals are: Discuss advances in science and technology relevant to test ban verification; Explore scientific applications of the CTBT verification infrastructure; Encourage partnerships and knowledge exchange between the CTBTO and the broader scientific community.

  16. Benchmark testing and independent verification of the VS2DT computer code

    International Nuclear Information System (INIS)

    McCord, J.T.

    1994-11-01

    The finite difference flow and transport simulator VS2DT was benchmark tested against several other codes which solve the same equations (Richards equation for flow and the Advection-Dispersion equation for transport). The benchmark problems investigated transient two-dimensional flow in a heterogeneous soil profile with a localized water source at the ground surface. The VS2DT code performed as well as or better than all other codes when considering mass balance characteristics and computational speed. It was also rated highly relative to the other codes with regard to ease-of-use. Following the benchmark study, the code was verified against two analytical solutions, one for two-dimensional flow and one for two-dimensional transport. These independent verifications show reasonable agreement with the analytical solutions, and complement the one-dimensional verification problems published in the code's original documentation

  17. Examples of verification knowledge and testing of the secondary students through the worksheet. Suggestions for leisure time activities

    International Nuclear Information System (INIS)

    Chmielewska, E.; Kuruc, J.

    2010-01-01

    In this chapter some examples of verification knowledge and testing of the secondary students through the worksheet as well as suggestions for leisure time activities are presented. Used and recommended literature is included.

  18. Testing and verification of a novel single-channel IGBT driver circuit

    Directory of Open Access Journals (Sweden)

    Lukić Milan

    2016-01-01

    Full Text Available This paper presents a novel single-channel IGBT driver circuit together with a procedure for testing and verification. It is based on a specialized integrated circuit with complete range of protective functions. Experiments are performed to test and verify its behaviour. Experimental results are presented in the form of oscilloscope recordings. It is concluded that the new driver circuit is compatible with modern IGBT transistors and power converter demands and that it can be applied in new designs. It is a part of new 20kW industrial-grade boost converter.

  19. Power Performance Verification of a Wind Farm Using the Friedman's Test.

    Science.gov (United States)

    Hernandez, Wilmar; López-Presa, José Luis; Maldonado-Correa, Jorge L

    2016-06-03

    In this paper, a method of verification of the power performance of a wind farm is presented. This method is based on the Friedman's test, which is a nonparametric statistical inference technique, and it uses the information that is collected by the SCADA system from the sensors embedded in the wind turbines in order to carry out the power performance verification of a wind farm. Here, the guaranteed power curve of the wind turbines is used as one more wind turbine of the wind farm under assessment, and a multiple comparison method is used to investigate differences between pairs of wind turbines with respect to their power performance. The proposed method says whether the power performance of the specific wind farm under assessment differs significantly from what would be expected, and it also allows wind farm owners to know whether their wind farm has either a perfect power performance or an acceptable power performance. Finally, the power performance verification of an actual wind farm is carried out. The results of the application of the proposed method showed that the power performance of the specific wind farm under assessment was acceptable.

  20. Power Performance Verification of a Wind Farm Using the Friedman’s Test

    Science.gov (United States)

    Hernandez, Wilmar; López-Presa, José Luis; Maldonado-Correa, Jorge L.

    2016-01-01

    In this paper, a method of verification of the power performance of a wind farm is presented. This method is based on the Friedman’s test, which is a nonparametric statistical inference technique, and it uses the information that is collected by the SCADA system from the sensors embedded in the wind turbines in order to carry out the power performance verification of a wind farm. Here, the guaranteed power curve of the wind turbines is used as one more wind turbine of the wind farm under assessment, and a multiple comparison method is used to investigate differences between pairs of wind turbines with respect to their power performance. The proposed method says whether the power performance of the specific wind farm under assessment differs significantly from what would be expected, and it also allows wind farm owners to know whether their wind farm has either a perfect power performance or an acceptable power performance. Finally, the power performance verification of an actual wind farm is carried out. The results of the application of the proposed method showed that the power performance of the specific wind farm under assessment was acceptable. PMID:27271628

  1. Power Performance Verification of a Wind Farm Using the Friedman’s Test

    Directory of Open Access Journals (Sweden)

    Wilmar Hernandez

    2016-06-01

    Full Text Available In this paper, a method of verification of the power performance of a wind farm is presented. This method is based on the Friedman’s test, which is a nonparametric statistical inference technique, and it uses the information that is collected by the SCADA system from the sensors embedded in the wind turbines in order to carry out the power performance verification of a wind farm. Here, the guaranteed power curve of the wind turbines is used as one more wind turbine of the wind farm under assessment, and a multiple comparison method is used to investigate differences between pairs of wind turbines with respect to their power performance. The proposed method says whether the power performance of the specific wind farm under assessment differs significantly from what would be expected, and it also allows wind farm owners to know whether their wind farm has either a perfect power performance or an acceptable power performance. Finally, the power performance verification of an actual wind farm is carried out. The results of the application of the proposed method showed that the power performance of the specific wind farm under assessment was acceptable.

  2. Non proliferation regimes undertakings: Benefits and limits of synergies in verification technologies and procedures

    International Nuclear Information System (INIS)

    Richard, M.

    2001-01-01

    Full text: Thirty years ago the NPT was entering into force. Therewith, when a State became party to the NPT, it had, in accordance with article III.1 of the Treaty, an undertaking to conclude a Comprehensive Safeguards agreement with the IAEA and accept safeguards verification on source or special fissionable material in all peaceful nuclear activities within its territories in order to verify that such material is not diverted. This multilateral instrument was the foundation stone of the non-proliferation regime and marked the actual birth of internationally accepted measures to verily compliance with politically stringent agreements. Since that time several important multilateral or bilateral instruments on non-proliferation and disarmament have been negotiated and adopted to curb the development and the acquisition of Weapons of Mass Destruction (WMD) most of them since the middle of the eighties and the collapse of the Soviet Union. Amongst the multilateral instruments are the Convention on the Prohibition of Bacteriological Weapon and Toxin Weapons (1972), the Convention on the Prohibition of Chemical Weapons (1993), the Comprehensive Test Ban Treaty (1996), the Strengthening of the IAEA Safeguards and the Additional Protocol (1997), with some still in negotiation like the Protocol of the Convention on the Prohibition of Bacteriological and Toxin Weapons, and some on which negotiation is still a wish like the Fissile Material Cut-off Treaty. Bilateral disarmament agreements between the United States of America and the Russian Federation such as the INF Treaty, START I and II, the agreements on the elimination of excess defence nuclear material as well as the Trilateral Initiative with the IAEA pave the way to nuclear disarmament with the reduction of both the number of nuclear weapons arsenal and the fissile material inventories. The politically stringent undertakings of States that have become parties to those agreements would not be possible without the

  3. Experimental verification of active IR stealth technology by controlling the surface temperature using a thermoelectric element

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Geon; Han, Kuk Il; Choi, Jun Hyuk; Kim, Tae Kuk [Dept. of Mechanical Engineering, Chung Ang University, Seoul (Korea, Republic of)

    2016-10-15

    In this paper, we propose a technique for IR low-observability that uses an active IR signal tuning through the real time control of the object surface temperature according to the varying background environment. This is achieved by applying the proper object surface temperature obtained to result in the minimum radiance difference between the object and the background. Experimental verification by using the thermoelectric temperature control element shows that the IR radiance contrast between the object and the background can be reduced up to 99% during the night and up to 95% during the day time as compared to the un-tuned original radiance contrast values. The stealth technology demonstrated in this paper may be applied for many military systems needed for the IR stealth performance when a suitable temperature control unit is developed.

  4. Experimental verification of active IR stealth technology by controlling the surface temperature using a thermoelectric element

    International Nuclear Information System (INIS)

    Kim, Dong Geon; Han, Kuk Il; Choi, Jun Hyuk; Kim, Tae Kuk

    2016-01-01

    In this paper, we propose a technique for IR low-observability that uses an active IR signal tuning through the real time control of the object surface temperature according to the varying background environment. This is achieved by applying the proper object surface temperature obtained to result in the minimum radiance difference between the object and the background. Experimental verification by using the thermoelectric temperature control element shows that the IR radiance contrast between the object and the background can be reduced up to 99% during the night and up to 95% during the day time as compared to the un-tuned original radiance contrast values. The stealth technology demonstrated in this paper may be applied for many military systems needed for the IR stealth performance when a suitable temperature control unit is developed

  5. Charpy impact test results on five materials and NIST verification specimens using instrumented 2-mm and 8-mm strikers

    International Nuclear Information System (INIS)

    Nanstad, R.K.; Sokolov, M.A.

    1995-01-01

    The Heavy-Section Steel Irradiation Program at Oak Ridge National Laboratory is involved in two cooperative projects, with international participants, both of which involve Charpy V-notch impact tests with instrumented strikers of 2mm and 8mm radii. Two heats of A 533 grade B class I pressure vessel steel and a low upper-shelf (LUS) submerged-arc (SA) weld were tested on the same Charpy machine, while one heat of a Russian Cr-Mo-V forging steel and a high upper-shelf (HUS) SA weld were tested on two different machines. The number of replicate tests at any one temperature ranged from 2 to 46 specimens. Prior to testing with each striker, verification specimens at the low, high, and super high energy levels from the National Institute of Standards and Technology (NIST) were tested. In the two series of verification tests, the tests with the 2mm striker met the requirements at the low and high energy levels but not at the super high energy. For one plate, the 2mm striker showed somewhat higher average absorbed energies than those for the 8-mm striker at all three test temperatures. For the second plate and the LUS weld, however, the 2mm striker showed somewhat lower energies at both test temperatures. For the Russian forging steel and the HUS weld, tests were conducted over a range of temperatures with tests at one laboratory using the 8mm striker and tests at a second laboratory using the 2mm striker. Lateral expansion was measured for all specimens and the results are compared with the absorbed energy results. The overall results showed generally good agreement (within one standard deviation) in energy measurements by the two strikers. Load-time traces from the instrumented strikers were also compared and used to estimate shear fracture percentage. Four different formulas from the European Structural Integrity Society draft standard for instrumented Charpy test are compared and a new formula is proposed for estimation of percent shear from the force-time trace

  6. Verification testing of the PKI collector at Sandia National Laboratories, Albuquerque, New Mexico

    Science.gov (United States)

    Hauger, J. S.; Pond, S. L.

    1982-07-01

    Verification testing of a solar collector was undertaken prior to its operation as part of an industrial process heat plant at Capitol Concrete Products in Topeka, Kansas. Testing was performed at a control plant installed at Sandia National Laboratory, Albuquerque, New Mexico (SNLA). Early results show that plant performance is even better than anticipated and far in excess of test criteria. Overall plant efficiencies of 65 to 80 percent were typical during hours of good insolation. A number of flaws and imperfections were detected during operability testing, the most important being a problem in elevation drive alignment due to a manufacturing error. All problems were corrected as they occurred and the plant, with over 40 hours of operation, is currently continuing operability testing in a wholly-automatic mode.

  7. Application of software technology to automatic test data analysis

    Science.gov (United States)

    Stagner, J. R.

    1991-01-01

    The verification process for a major software subsystem was partially automated as part of a feasibility demonstration. The methods employed are generally useful and applicable to other types of subsystems. The effort resulted in substantial savings in test engineer analysis time and offers a method for inclusion of automatic verification as a part of regression testing.

  8. SORO post-simulations of Bruce A Unit 4 in-core flux detector verification tests

    Energy Technology Data Exchange (ETDEWEB)

    Braverman, E.; Nainer, O. [Bruce Power, Nuclear Safety Analysis and Support Dept., Toronto, Ontario (Canada)]. E-mail: Evgeny.Braverman@brucepower.com; Ovidiu.Nainer@brucepower.com

    2004-07-01

    During the plant equipment assessment prior to requesting approval for restart of Bruce A Units 3 and 4 it was determined that all in-core flux detectors needed to be replaced. Flux detector verification tests were performed to confirm that the newly installed detectors had been positioned according to design specifications and that their response closely follows the calculated flux shape changes caused by selected reactivity mechanism movements. By comparing the measured and post-simulated RRS and NOP detector responses to various perturbations, it was confirmed that the new detectors are wired and positioned correctly. (author)

  9. Selected Examples of LDRD Projects Supporting Test Ban Treaty Verification and Nonproliferation

    Energy Technology Data Exchange (ETDEWEB)

    Jackson, K. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Al-Ayat, R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Walter, W. R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-02-23

    The Laboratory Directed Research and Development (LDRD) Program at the DOE National Laboratories was established to ensure the scientific and technical vitality of these institutions and to enhance the their ability to respond to evolving missions and anticipate national needs. LDRD allows the Laboratory directors to invest a percentage of their total annual budget in cutting-edge research and development projects within their mission areas. We highlight a selected set of LDRD-funded projects, in chronological order, that have helped provide capabilities, people and infrastructure that contributed greatly to our ability to respond to technical challenges in support of test ban treaty verification and nonproliferation.

  10. Bias associated with delayed verification in test accuracy studies: accuracy of tests for endometrial hyperplasia may be much higher than we think!

    Directory of Open Access Journals (Sweden)

    Coomarasamy Aravinthan

    2004-05-01

    Full Text Available Abstract Background To empirically evaluate bias in estimation of accuracy associated with delay in verification of diagnosis among studies evaluating tests for predicting endometrial hyperplasia. Methods Systematic reviews of all published research on accuracy of miniature endometrial biopsy and endometr ial ultrasonography for diagnosing endometrial hyperplasia identified 27 test accuracy studies (2,982 subjects. Of these, 16 had immediate histological verification of diagnosis while 11 had verification delayed > 24 hrs after testing. The effect of delay in verification of diagnosis on estimates of accuracy was evaluated using meta-regression with diagnostic odds ratio (dOR as the accuracy measure. This analysis was adjusted for study quality and type of test (miniature endometrial biopsy or endometrial ultrasound. Results Compared to studies with immediate verification of diagnosis (dOR 67.2, 95% CI 21.7–208.8, those with delayed verification (dOR 16.2, 95% CI 8.6–30.5 underestimated the diagnostic accuracy by 74% (95% CI 7%–99%; P value = 0.048. Conclusion Among studies of miniature endometrial biopsy and endometrial ultrasound, diagnostic accuracy is considerably underestimated if there is a delay in histological verification of diagnosis.

  11. Standard practices for verification of displacement measuring systems and devices used in material testing machines

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 These practices cover procedures and requirements for the calibration and verification of displacement measuring systems by means of standard calibration devices for static and quasi-static testing machines. This practice is not intended to be complete purchase specifications for testing machines or displacement measuring systems. Displacement measuring systems are not intended to be used for the determination of strain. See Practice E83. 1.2 These procedures apply to the verification of the displacement measuring systems associated with the testing machine, such as a scale, dial, marked or unmarked recorder chart, digital display, etc. In all cases the buyer/owner/user must designate the displacement-measuring system(s) to be verified. 1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems m...

  12. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: HVLP COATING EQUIPMENT, ITW AUTOMOTIVE REFINISHING, DEVILBISS FLG-631-318 HVLP SPRAY GUN

    Science.gov (United States)

    This report presents the results of the verification test of the DeVilbiss FLG-631-318 high-volume, low-pressure gravity-feed spray gun, hereafter referred to as the DeVilbiss FLG, which is designed for use in automotive refinishing. The test coating chosen by ITW Automotive Refi...

  13. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: HVLP COATING EQUIPMENT, ITW AUTOMOTIVE REFINISHING, DEVILBISS GTI-600G, HVLP SPRAY GUN

    Science.gov (United States)

    This report presents the results of the verification test of the DeVilbiss GTi-600G high-volume, low-pressure gravity-feed spray gun, hereafter referred to as the DeVilbiss GTi, which is designed for use in automotive refinishing. The test coating chosen by ITW Automotive Refinis...

  14. Remote sensing and geoinformation technologies in support of nuclear non-proliferation and arms control verification regimes

    Energy Technology Data Exchange (ETDEWEB)

    Niemeyer, Irmgard [Forschungszentrum Juelich GmbH, Institut fuer Energie- und Klimaforschung, IEK-6: Nukleare Entsorgung und Reaktorsicherheit (Germany)

    2013-07-01

    A number of international agreements and export control regimes have been concluded in order to reduce the risk and proliferation of weapons of mass destruction. In order to provide confidence that Member States are complying with the agreed commitments, most of the treaties and agreements include verification provisions. Different types of verification measures exist, e.g. cooperative measures; national technical means; technical monitoring or measurement devices placed at or near sites; on-site inspections; intelligence information; open-source information, such as commercial internet data and satellite imagery. The study reviews the technical progress in the field of satellite imaging sensors and explores the recent advances in satellite imagery processing and geoinformation technologies as to the extraction of significant observables and signatures. Moreover, it discusses how satellite data and geoinformation technologies could be used complementary for confirming information gathered from other systems or sources. The study also aims at presenting the legal and political aspects and the cost benefits of using imagery from both national and commercial satellites in the verification procedure. The study concludes that satellite imagery and geoinformation technologies are expected to enhance the verification efficiency and effectiveness.

  15. Bias associated with delayed verification in test accuracy studies: accuracy of tests for endometrial hyperplasia may be much higher than we think!

    OpenAIRE

    Clark, T Justin; ter Riet, Gerben; Coomarasamy, Aravinthan; Khan, Khalid S

    2004-01-01

    Abstract Background To empirically evaluate bias in estimation of accuracy associated with delay in verification of diagnosis among studies evaluating tests for predicting endometrial hyperplasia. Methods Systematic reviews of all published research on accuracy of miniature endometrial biopsy and endometr ial ultrasonography for diagnosing endometrial hyperplasia identified 27 test accuracy studies (2,982 subjects). Of these, 16 had immediate histological verification of diagnosis while 11 ha...

  16. Verification of FPGA-Signal using the test board which is applied to Safety-related controller

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Youn-Hu; Yoo, Kwanwoo; Lee, Myeongkyun; Yun, Donghwa [SOOSAN ENS, Seoul (Korea, Republic of)

    2016-10-15

    This article aims to provide the verification method for BGA-type FPGA of Programmable Logic Controller (PLC) developed as Safety Class. The logic of FPGA in the control device with Safety Class is the circuit to control overall logic of PLC. Saftety-related PLC must meet the international standard specifications. With this reason, we use V and V according to an international standard in order to secure high reliability and safety. By using this, we are supposed to proceed to a variety of verification courses for extra reliability and safety analysis. In order to have efficient verification of test results, we propose the test using the newly changed BGA socket which can resolve the problems of the conventional socket on this paper. The Verification of processes is divided into verification of Hardware and firmware. That processes are carried out in the unit testing and integration testing. The proposed test method is simple, the effect of cost reductions by batch process. In addition, it is advantageous to measure the signal from the Hi-speed-IC due to its short length of the pins and it was plated with the copper around it. Further, it also to prevent abrasion on the IC ball because it has no direct contact with the PCB. Therefore, it can be actually applied is to the BGA package test and we can easily verify logic as well as easily checking the operation of the designed data.

  17. Verification Test for Ultra-Light Deployment Mechanism for Sectioned Deployable Antenna Reflectors

    Science.gov (United States)

    Zajac, Kai; Schmidt, Tilo; Schiller, Marko; Seifart, Klaus; Schmalbach, Matthias; Scolamiero, Lucio

    2013-09-01

    The ultra-light deployment mechanism (UDM) is based on three carbon fibre reinforced plastics (CFRP) curved tape springs made of carbon fibre / cyanate ester prepregs.In the frame of the activity its space application suitability for the deployment of solid reflector antenna sections was investigated. A projected diameter of the full reflector of 4 m to 7 m and specific mass in the order of magnitude of 2.6kg/m2 was focused for requirement derivation.Extensive verification tests including health checks, environmental and functional tests were carried out with an engineering model to enable representative characterizing of the UDM unit.This paper presents the design and a technical description of the UDM as well as a summary of achieved development status with respect to test results and possible design improvements.

  18. Constrained structural dynamic model verification using free vehicle suspension testing methods

    Science.gov (United States)

    Blair, Mark A.; Vadlamudi, Nagarjuna

    1988-01-01

    Verification of the validity of a spacecraft's structural dynamic math model used in computing ascent (or in the case of the STS, ascent and landing) loads is mandatory. This verification process requires that tests be carried out on both the payload and the math model such that the ensuing correlation may validate the flight loads calculations. To properly achieve this goal, the tests should be performed with the payload in the launch constraint (i.e., held fixed at only the payload-booster interface DOFs). The practical achievement of this set of boundary conditions is quite difficult, especially with larger payloads, such as the 12-ton Hubble Space Telescope. The development of equations in the paper will show that by exciting the payload at its booster interface while it is suspended in the 'free-free' state, a set of transfer functions can be produced that will have minima that are directly related to the fundamental modes of the payload when it is constrained in its launch configuration.

  19. Development of an automated testing system for verification and validation of nuclear data

    International Nuclear Information System (INIS)

    Triplett, B. S.; Anghaie, S.; White, M. C.

    2008-01-01

    Verification and validation of nuclear data is critical to the accuracy of both stochastic and deterministic particle transport codes. In order to effectively test a set of nuclear data, the data must be applied to a wide variety of transport problems. Performing this task in a timely, efficient manner is tedious. The nuclear data team at Los Alamos National Laboratory (LANL) in collaboration with the University of Florida is developing a methodology to automate the process of nuclear data verification and validation. The International Criticality Safety Benchmark Experiment Project (ICSBEP) provides a set of criticality problems that may be used to evaluate nuclear data. This process tests a number of data libraries using cases from the ICSBEP benchmark set to demonstrate how automation of these tasks may reduce errors and increase efficiency. The process is driven by an integrated set of Python scripts. Material and geometry data may be read from an existing code input file to generate a standardized template or the template may be generated directly by the user The user specifies the desired precision and other vital problem parameters. The Python scripts generate input decks for multiple transport codes from these templates, run and monitor individual jobs, and parse the relevant output. This output can then be used to generate reports directly or can be stored into a database for later analysis. This methodology eases the burden on the user by reducing the amount of time and effort required for obtaining and compiling calculation results. (authors)

  20. Evaluation of detector array technology for the verification of advanced intensity-modulated radiotherapy

    Science.gov (United States)

    Hussien, Mohammad

    Purpose: Quality assurance (QA) for intensity modulated radiotherapy (IMRT) has evolved substantially. In recent years, various ionization chamber or diode detector arrays have become commercially available, allowing pre-treatment absolute dose verification with near real-time results. This has led to a wide uptake of this technology to replace point dose and film dosimetry and to facilitate QA streamlining. However, arrays are limited by their spatial resolution giving rise to concerns about their response to clinically relevant deviations. The common factor in all commercial array systems is the reliance on the gamma index (γ) method to provide the quantitative evaluation of the measured dose distribution against the Treatment Planning System (TPS) calculated dose distribution. The mathematical definition of the gamma index presents computational challenges that can cause a variation in the calculation in different systems. The purpose of this thesis was to evaluate the suitability of detector array systems, combined with their implementation of the gamma index, in the verification and dosimetry audit of advanced IMRT. Method: The response of various commercial detector array systems (Delta4®, ArcCHECK®, and the PTW 2D-Array seven29™ and OCTAVIUS II™ phantom combination, Gafchromic® EBT2 and composite EPID measurements) to simulated deliberate changes in clinical IMRT and VMAT plans was evaluated. The variability of the gamma index calculation in the different systems was also evaluated by comparing against a bespoke Matlab-based gamma index analysis software. A novel methodology for using a commercial detector array in a dosimetry audit of rotational radiotherapy was then developed. Comparison was made between measurements using the detector array and those performed using ionization chambers, alanine and radiochromic film. The methodology was developed as part of the development of a national audit of rotational radiotherapy. Ten cancer centres were

  1. Incremental Approach to the Technology of Test Design for Industrial Projects

    Directory of Open Access Journals (Sweden)

    P. D. Drobintsev

    2014-01-01

    Full Text Available The paper presents an approach to effort reduction in developing test suites for industrial software products based on the incremental technology. The main problems to be solved by the incremental technology are full automation design of test scenarios and significant reducing of test explosion. The proposed approach provides solutions to the mentioned problems through joint co-working of a designer and a customer, through the integration of symbolic verification with the automatic generation of test suites; through the usage of an efficient technology with the toolset VRS/TAT.

  2. Achievement report for fiscal 1981 Sunshine Program on development of practical application technologies for photovoltaic power systems. Test production and verification of solar panels (Development of polycrystalline substrate process technologies); 1981 nendo taiyoko hatsuden system jitsuyoka gijutsu kaihatsu seika hokokusho. Taiyo denchi panel jikken seisaku kensho (takessho kiban kotei no gijutsu kaihatsu)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1982-03-01

    Studies are conducted to enlarge the diameter of polycrystalline Si castings and to develop a low-loss slicing method using silicon nitride powder as mold releasing agent. The apparatus for Czochralski's pulling process is improved and tested using SEG (selective epitaxial growth) Si, and now the casting of a 150mm-diameter ingot is feasible. Also, test production of a 94mm-square wafer as specified by NEDO (New Energy and Industrial Technology Development Organization) is successfully carried out. Difficulties in separating the mold releasing agent from the crucible are solved by changing the Si{sub 3}N{sub 4} power solution from PVA (polyvinyl alcohol) to ethyl silicate. The design, manufacture, and installation of the important parts of the system for the mass production of castings are now complete. The crucible is designed to be movable relative to the heater section, and the molten Si is allowed to cool and solidify from the bottom upward. In relation with the development of low-cost wafer manufacturing technologies, low-loss slicing methods are studied. It is concluded that under the current circumstances a multi-blade saw is more promising than the multi-wire saw in view of the damaged slice rate, processing speed, operating cost, and maintainability. (NEDO)

  3. Tensit - a novel probabilistic simulation tool for safety assessments. Tests and verifications using biosphere models

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Jakob; Vahlund, Fredrik; Kautsky, Ulrik

    2004-06-01

    This report documents the verification of a new simulation tool for dose assessment put together in a package under the name Tensit (Technical Nuclide Simulation Tool). The tool is developed to solve differential equation systems describing transport and decay of radionuclides. It is capable of handling both deterministic and probabilistic simulations. The verifications undertaken shows good results. Exceptions exist only where the reference results are unclear. Tensit utilise and connects two separate commercial softwares. The equation solving capability is derived from the Matlab/Simulink software environment to which Tensit adds a library of interconnectable building blocks. Probabilistic simulations are provided through a statistical software named at{sub R}isk that communicates with Matlab/Simulink. More information about these softwares can be found at www.palisade.com and www.mathworks.com. The underlying intention of developing this new tool has been to make available a cost efficient and easy to use means for advanced dose assessment simulations. The mentioned benefits are gained both through the graphical user interface provided by Simulink and at{sub R}isk, and the use of numerical equation solving routines in Matlab. To verify Tensit's numerical correctness, an implementation was done of the biosphere modules for dose assessments used in the earlier safety assessment project SR 97. Acquired probabilistic results for deterministic as well as probabilistic simulations have been compared with documented values. Additional verification has been made both with another simulation tool named AMBER and also against the international test case from PSACOIN named Level 1B. This report documents the models used for verification with equations and parameter values so that the results can be recreated. For a background and a more detailed description of the underlying processes in the models, the reader is referred to the original references. Finally, in the

  4. Tensit - a novel probabilistic simulation tool for safety assessments. Tests and verifications using biosphere models

    International Nuclear Information System (INIS)

    Jones, Jakob; Vahlund, Fredrik; Kautsky, Ulrik

    2004-06-01

    This report documents the verification of a new simulation tool for dose assessment put together in a package under the name Tensit (Technical Nuclide Simulation Tool). The tool is developed to solve differential equation systems describing transport and decay of radionuclides. It is capable of handling both deterministic and probabilistic simulations. The verifications undertaken shows good results. Exceptions exist only where the reference results are unclear. Tensit utilise and connects two separate commercial softwares. The equation solving capability is derived from the Matlab/Simulink software environment to which Tensit adds a library of interconnectable building blocks. Probabilistic simulations are provided through a statistical software named at R isk that communicates with Matlab/Simulink. More information about these softwares can be found at www.palisade.com and www.mathworks.com. The underlying intention of developing this new tool has been to make available a cost efficient and easy to use means for advanced dose assessment simulations. The mentioned benefits are gained both through the graphical user interface provided by Simulink and at R isk, and the use of numerical equation solving routines in Matlab. To verify Tensit's numerical correctness, an implementation was done of the biosphere modules for dose assessments used in the earlier safety assessment project SR 97. Acquired probabilistic results for deterministic as well as probabilistic simulations have been compared with documented values. Additional verification has been made both with another simulation tool named AMBER and also against the international test case from PSACOIN named Level 1B. This report documents the models used for verification with equations and parameter values so that the results can be recreated. For a background and a more detailed description of the underlying processes in the models, the reader is referred to the original references. Finally, in the perspective of

  5. SASSYS-1 computer code verification with EBR-II test data

    International Nuclear Information System (INIS)

    Warinner, D.K.; Dunn, F.E.

    1985-01-01

    The EBR-II natural circulation experiment, XX08 Test 8A, is simulated with the SASSYS-1 computer code and the results for the latter are compared with published data taken during the transient at selected points in the core. The SASSYS-1 results provide transient temperature and flow responses for all points of interest simultaneously during one run, once such basic parameters as pipe sizes, initial core flows, and elevations are specified. The SASSYS-1 simulation results for the EBR-II experiment XX08 Test 8A, conducted in March 1979, are within the published plant data uncertainties and, thereby, serve as a partial verification/validation of the SASSYS-1 code

  6. Integrated verification and testing system (IVTS) for HAL/S programs

    Science.gov (United States)

    Senn, E. H.; Ames, K. R.; Smith, K. A.

    1983-01-01

    The IVTS is a large software system designed to support user-controlled verification analysis and testing activities for programs written in the HAL/S language. The system is composed of a user interface and user command language, analysis tools and an organized data base of host system files. The analysis tools are of four major types: (1) static analysis, (2) symbolic execution, (3) dynamic analysis (testing), and (4) documentation enhancement. The IVTS requires a split HAL/S compiler, divided at the natural separation point between the parser/lexical analyzer phase and the target machine code generator phase. The IVTS uses the internal program form (HALMAT) between these two phases as primary input for the analysis tools. The dynamic analysis component requires some way to 'execute' the object HAL/S program. The execution medium may be an interpretive simulation or an actual host or target machine.

  7. TRAC-PF1 code verification with data from the OTIS test facility

    International Nuclear Information System (INIS)

    Childerson, M.T.; Fujita, R.K.

    1985-01-01

    A computer code (TRAC-PF1/MOD1) developed for predicting transient thermal and hydraulic integral nuclear steam supply system (NSSS) response was benchmarked. Post-small break loss-of-coolant accident (LOCA) data from a scaled, experimental facility, designated the One-Through Integral System (OTIS), were obtained for the Babcock and Wilcox NSSS and compared to TRAC predictions. The OTIS tests provided a challenging small break LOCA data set for TRAC verification. The major phases of a small break LOCA observed in the OTIS tests included pressurizer draining and loop saturation, intermittent reactor coolant system circulation, boiler-condenser mode, and the initial stages of refill. The TRAC code was successful in predicting OTIS loop conditions (system pressures and temperatures) after modification of the steam generator model. In particular, the code predicted both pool and auxiliary-feedwater initiated boiler-condenser mode heat transfer

  8. TRAC-PF1 code verification with data from the OTIS test facility

    International Nuclear Information System (INIS)

    Childerson, M.T.; Fujits, R.K.

    1985-01-01

    A computer code (TRAC-PFI/MODI; denoted as TRAC) developed for predicting transient thermal and hydraulic integral nuclear steam supply system (NSSS) response was benchmarked. Post-small break loss-of-coolant accident (LOCA) data from a scaled, experimental facility, designated the Once-Through Integral Systems (OTIS), were obtained for the Babcock and Wilcox NSSS and compared to TRAC predictions. The OTIS tests provided a challenging small break LOCA data set for TRAC verification. The major phases of a small break LOCA observed in the OTIS tests included pressurizer draining and saturation, intermittent reactor coolant system circulation, boiler-condenser mode and the initial stages of refill. The TRAC code was successful in predicting OTIS loop conditions (system pressures and temperatures) after modification of the steam generator model. In particular, the code predicted both pool- and auxiliary- feedwater initiated boiler-condenser mode heat transfer

  9. Verification test for on-line diagnosis algorithm based on noise analysis

    International Nuclear Information System (INIS)

    Tamaoki, T.; Naito, N.; Tsunoda, T.; Sato, M.; Kameda, A.

    1980-01-01

    An on-line diagnosis algorithm was developed and its verification test was performed using a minicomputer. This algorithm identifies the plant state by analyzing various system noise patterns, such as power spectral densities, coherence functions etc., in three procedure steps. Each obtained noise pattern is examined by using the distances from its reference patterns prepared for various plant states. Then, the plant state is identified by synthesizing each result with an evaluation weight. This weight is determined automatically from the reference noise patterns prior to on-line diagnosis. The test was performed with 50 MW (th) Steam Generator noise data recorded under various controller parameter values. The algorithm performance was evaluated based on a newly devised index. The results obtained with one kind of weight showed the algorithm efficiency under the proper selection of noise patterns. Results for another kind of weight showed the robustness of the algorithm to this selection. (orig.)

  10. Development of Design Concept and Applied Technology for RCP Performance Test Facility

    International Nuclear Information System (INIS)

    Park, Sang Jin; Lee, Jung Ho; Yoon, Seok Ho

    2010-02-01

    Performance test facility for RCP (reactor coolant pump) is essential to verify the performance and reliability of RCP before installation in the nuclear power plant. The development of RCP for new-type reactor and the performance verification of hydraulic revolving body also needs the RCP test facility. The design concept of test loop and the technology of flow rate measurement are investigated in this research

  11. Research on key technology of the verification system of steel rule based on vision measurement

    Science.gov (United States)

    Jia, Siyuan; Wang, Zhong; Liu, Changjie; Fu, Luhua; Li, Yiming; Lu, Ruijun

    2018-01-01

    The steel rule plays an important role in quantity transmission. However, the traditional verification method of steel rule based on manual operation and reading brings about low precision and low efficiency. A machine vison based verification system of steel rule is designed referring to JJG1-1999-Verificaiton Regulation of Steel Rule [1]. What differentiates this system is that it uses a new calibration method of pixel equivalent and decontaminates the surface of steel rule. Experiments show that these two methods fully meet the requirements of the verification system. Measuring results strongly prove that these methods not only meet the precision of verification regulation, but also improve the reliability and efficiency of the verification system.

  12. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT. STORMWATER SOURCE AREA TREATMENT DEVICE. THE TERRE HILL CONCRETE PRODUCTS TERRE KLEEN™ 09

    Science.gov (United States)

    Verification testing of the Terre Hill Concrete Products Terre Kleen™ 09 was conducted on a 1.27 acre portion of the City of Harrisburg, Pennsylvania Department of Public Works facility. The Terre Kleen™ devices combines primary and secondary chambers, baffles, a screen, and incl...

  13. Design verification and acceptance tests of the ASST-A helium refrigeration system

    International Nuclear Information System (INIS)

    Ganni, V.; Apparao, T.V.V.R.

    1993-07-01

    Three similar helium refrigerator systems have been installed at the Superconducting Super Collider Laboratory (SSCL) N15 site; the ASST-A system, which will be used for the accelerator system's full cell string test; the N15-B system, which will be used for string testing in the tunnel; and a third plant, dedicated to magnet testing at the Magnet Testing Laboratory. The ASST-A and N15-B systems will ultimately be a part of the collider's N15 sector station equipment. Each of these three systems has many subsystems, but the design basis for the main refrigerator is the same. Each system has a guaranteed capacity of 2000 W of refrigeration and 20 g/s liquefaction at 4.5K. The testing and design verification of the ASST-A refrigeration system consisted of parametric tests on the compressors and the total system. A summary of the initial performance test data is given in this paper. The tests were conducted for two cases: in the first, all four compressors were operating; in the second, only one compressor in each stage was operating. In each case, tests were conducted in three modes of operation described later on. The process design basis supplied by the manufacturers and used in the design of the main components -- the compressor, and expanders and heat exchangers for the coldbox -- were used to reduce the actual test data using process simulation methodology. In addition, the test results and the process design submitted by the manufacturer were analyzed using exergy analysis. This paper presents both the process and the exergy analyses of the manufacturer's design and the actual test data for Case 1. The process analyses are presented in the form of T-S diagrams. The results of the exergy analyses comparing the exergy losses of each component and the total system for the manufacturer's design and the test data are presented in the tables

  14. Testing the algorithms for automatic identification of errors on the measured quantities of the nuclear power plant. Verification tests

    International Nuclear Information System (INIS)

    Svatek, J.

    1999-12-01

    During the development and implementation of supporting software for the control room and emergency control centre at the Dukovany nuclear power plant it appeared necessary to validate the input quantities in order to assure operating reliability of the software tools. Therefore, the development of software for validation of the measured quantities of the plant data sources was initiated, and the software had to be debugged and verified. The report contains the proposal for and description of the verification tests for testing the algorithms of automatic identification of errors on the observed quantities of the NPP by means of homemade validation software. In particular, the algorithms treated serve the validation of the hot leg temperature at primary circuit loop no. 2 or 4 at the Dukovany-2 reactor unit using data from the URAN and VK3 information systems, recorded during 3 different days. (author)

  15. Inverse transport for the verification of the Comprehensive Nuclear Test Ban Treaty

    Directory of Open Access Journals (Sweden)

    J.-P. Issartel

    2003-01-01

    Full Text Available An international monitoring system is being built as a verification tool for the Comprehensive Test Ban Treaty. Forty stations will measure on a worldwide daily basis the concentration of radioactive noble gases. The paper introduces, by handling preliminary real data, a new approach of backtracking for the identification of sources of passive tracers after positive measurements. When several measurements are available the ambiguity about possible sources is reduced significantly. The approach is validated against ETEX data. A distinction is made between adjoint and inverse transport shown to be, indeed, different though equivalent ideas. As an interesting side result it is shown that, in the passive tracer dispersion equation, the diffusion stemming from a time symmetric turbulence is necessarily a self-adjoint operator, a result easily verified for the usual gradient closure, but more general.

  16. General-purpose heat source safety verification test series: SVT-11 through SVT-13

    International Nuclear Information System (INIS)

    George, T.G.; Pavone, D.

    1986-05-01

    The General-Purpose Heat Source (GPHS) is a modular component of the radioisotope thermoelectric generator that will provide power for the Galileo and Ulysses (formerly ISPM) space missions. The GPHS provides power by transmitting the heat of 238 Pu α-decay to an array of thermoelectric elements. Because the possibility of an orbital abort always exists, the heat source was designed and constructed to minimize plutonia release in any accident environment. The Safety Verification Test (SVT) series was formulated to evaluate the effectiveness of GPHS plutonia containment after atmospheric reentry and Earth impact. The first two reports (covering SVT-1 through SVT-10) described the results of flat, side-on, and angular module impacts against steel targets at 54 m/s. This report describes flat-on module impacts against concrete and granite targets, at velocities equivalent to or higher than previous SVTs

  17. Achievement report for fiscal 1998 on the development of superconductor power application technology. 2. Research and development of superconducting wire and superconductive power generator, research of total system, research and development of refrigeration system, and verification test; 1998 nendo chodendo denryoku oyo gijutsu kaihatsu seika hokokusho. 2. Chodendo senzai no kenkyu kaihatsu, chodendo hatsudenki no kenkyu kaihatsu, total sytsem no kenkyu, reito system no kenkyu kaihatsu, jissho shiken

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    The slow excitation response type power generator is studied when the rotor and stator of a 70,000kW-class model are combinedly subjected to an on-site verification test, when a good result is obtained. The rotor is disassembled for inspection, and its members are found to be sound without any problem in terms of mechanical strength. The quick excitation response type is studied when a 70,000kW model is experimentally built and subjected to an on-site verification test after a rotation and excitation test in the factory, when the pilot machine concept design is reviewed. In the study of a total system, efforts continue for the review of the model machine test method, improvement on generator design and analytical methods, development of operating methods, and the effect of its introduction into the power system. Since a He-refrigerated system is requested to exhibit high reliability for application to power equipment and to be capable of continuous long-period operation, a system having constituents with their reliability enhanced and an appropriate redundant system is developed, and a verification study is under way which will continue for more than 10,000 hours. Described also is an oil-free low-temperature turbo refrigerator. The latest quick excitation response type rotor is also tested for verification. (NEDO)

  18. BEval: A Plug-in to Extend Atelier B with Current Verification Technologies

    Directory of Open Access Journals (Sweden)

    Valério Medeiros Jr.

    2014-01-01

    Full Text Available This paper presents BEval, an extension of Atelier B to improve automation in the verification activities in the B method or Event-B. It combines a tool for managing and verifying software projects (Atelier B and a model checker/animator (ProB so that the verification conditions generated in the former are evaluated with the latter. In our experiments, the two main verification strategies (manual and automatic showed significant improvement as ProB's evaluator proves complementary to Atelier B built-in provers. We conducted experiments with the B model of a micro-controller instruction set; several verification conditions, that we were not able to discharge automatically or manually with AtelierB's provers, were automatically verified using BEval.

  19. The verification tests of residual radioactivity measurement and assessment techniques for buildings and soils

    International Nuclear Information System (INIS)

    Onozawa, T.; Ishikura, T.; Yoshimura, Yukio; Nakazawa, M.; Makino, S.; Urayama, K.; Kawasaki, S.

    1996-01-01

    According to the standard procedure for decommissioning a commercial nuclear power plant (CNPP) in Japan, controlled areas will be released for unrestricted use before the dismantling of a reactor building. If manual survey and sampling techniques were applied to measurement for unrestricted release on and in the extensive surface of the building, much time and much specialized labor would be required to assess the appropriateness of the releasing. Therefore the authors selected the following three techniques for demonstrating reliability and applicability of the techniques for CNPPs: (1) technique of assessing radioactive concentration distribution on the surface of buildings (ADB); (2) technique of assessing radioactive permeation distribution in the concrete structure of buildings (APB); (3) technique of assessing radioactive concentration distribution in soil (ADS). These tests include the techniques of measuring and assessing very low radioactive concentration distribution on the extensive surfaces of buildings and the soil surrounding of a plant with automatic devices. Technical investigation and preliminary study of the verification tests were started in 1990. In the study, preconditions were clarified for each technique and the performance requirements were set up. Moreover, simulation models have been constructed for several feasible measurement method to assess their performance in terms of both measurement test and simulation analysis. Fundamental tests have been under way using small-scale apparatuses since 1994

  20. Verification test of the SURF and SURFplus models in xRage

    Energy Technology Data Exchange (ETDEWEB)

    Menikoff, Ralph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-05-18

    As a verification test of the SURF and SURFplus models in the xRage code we use a propagating underdriven detonation wave in 1-D. This is about the only test cases for which an accurate solution can be determined based on the theoretical structure of the solution. The solution consists of a steady ZND reaction zone profile joined with a scale invariant rarefaction or Taylor wave and followed by a constant state. The end of the reaction profile and the head of the rarefaction coincide with the sonic CJ state of the detonation wave. The constant state is required to match a rigid wall boundary condition. For a test case, we use PBX 9502 with the same EOS and burn rate as previously used to test the shock detector algorithm utilized by the SURF model. The detonation wave is propagated for 10 μs (slightly under 80mm). As expected, the pointwise errors are largest in the neighborhood of discontinuities; pressure discontinuity at the lead shock front and pressure derivative discontinuities at the head and tail of the rarefaction. As a quantitative measure of the overall accuracy, the L2 norm of the difference of the numerical pressure and the exact solution is used. Results are presented for simulations using both a uniform grid and an adaptive grid that refines the reaction zone.

  1. Production controls (PC) and technical verification testing (TVT). A methodology for the control and tracking of LILW waste package conditioning

    International Nuclear Information System (INIS)

    Leon, A.M.; Nieto, J.L.L.; Garrido, J.G.

    2003-01-01

    As part of its low and intermediate level radioactive waste (LILW) characterisation and acceptance activities, ENRESA has set up a quality control programme that covers the different phases of radioactive waste package production and implies different levels of tracking in generation, assessment of activity and control of the documentation associated therewith. Furthermore, ENRESA has made available the mechanisms required for verification, depending on the results of periodic sampling, of the quality of the end product delivered by the waste producers. Both processes are included within the framework of two programmes of complementary activities: production controls (PC) and technical verification testing (TVT). (orig.)

  2. AXAF-I Low Intensity-Low Temperature (LILT) Testing of the Development Verification Test (DVT) Solar Panel

    Science.gov (United States)

    Alexander, Doug; Edge, Ted; Willowby, Doug

    1998-01-01

    The planned orbit of the AXAF-I spacecraft will subject the spacecraft to both short, less than 30 minutes for solar and less than 2 hours for lunar, and long earth eclipses and lunar eclipses with combined conjunctive duration of up to 3 to 4 hours. Lack of proper Electrical Power System (EPS) conditioning prior to eclipse may cause loss of mission. To avoid this problem, for short eclipses, it is necessary to off-point the solar array prior to or at the beginning of the eclipse to reduce the battery state of charge (SOC). This yields less overcharge during the high charge currents at sun entry. For long lunar eclipses, solar array pointing and load scheduling must be tailored for the profile of the eclipse. The battery SOC, loads, and solar array current-voltage (I-V) must be known or predictable to maintain the bus voltage within acceptable range. To address engineering concerns about the electrical performance of the AXAF-I solar array under Low Intensity and Low Temperature (LILT) conditions, Marshall Space Flight Center (MSFC) engineers undertook special testing of the AXAF-I Development Verification Test (DVT) solar panel in September-November 1997. In the test the DVT test panel was installed in a thermal vacuum chamber with a large view window with a mechanical "flapper door". The DVT test panel was "flash" tested with a Large Area Pulse Solar Simulator (LAPSS) at various fractional sun intensities and panel (solar cell) temperatures. The testing was unique with regards to the large size of the test article and type of testing performed. The test setup, results, and lessons learned from the testing will be presented.

  3. Testing and analysis SDN technology

    Directory of Open Access Journals (Sweden)

    Taher Abdullah

    2014-10-01

    Full Text Available The Software Defined Networking (SDN is currently one of the most promising technologies in mobile backhaul networks based on the OpenFlow protocol. OpenFlow provides a specification to migrate the control logic from a switch into the controller. In this paper we apply Mininet software to verify the OpenFlow protocol messages.

  4. Survey for development feasibility in fiscal 1999 investigation of geothermal development and promotion. Evaluation report on practicability technology survey SWD method (Evaluation report concerning verification test); 1999 nendo chinetsu kaihatsu sokushin chosa no uchi kaihatsu kanosei chosa. Jitsuyoka gijutsu chosa SWD ho hyoka hokokusho (jissho shiken ni kakawaru hyoka hokokusho)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-05-01

    An evaluation test was conducted on SWD (Seismic While Drilling) method as a part of the investigation of geothermal development and promotion. The test was implemented at the time of drilling of N11-MD-3 well in the northeast base area of Busadake, Hokkaido. The test items were such as verification of direct waves propagating from a bit to the surface, identification of signals passing through a fault zone using direct waves and reflected waves, estimation of distance between a fault and a bent zone, and grasping the direction of signal propagation at the time of inclined drilling. As a result of the experiments and studies, following conclusions were obtained. Reflected waves extracted are not necessarily limited to those from a reflection area from which the shape of a fault can be grasped; unless there is a clear reflection area that can be picked up on the surface near a fault, the application of this method is not effective. In an analysis using direct waves, it was possible to obtain an inclined angle of a fault plane from the estimation of velocity structure, propagation route, and assumption of the shape of the fault plane and, therefore, to grasp the shape of the fault. Obtaining reference data is essential for identifying bit signals. (NEDO)

  5. Achievement report for fiscal 1996 on the research and development of superconductor technology to power generation. Pt. 1. Research and development of superconducting wire, generator, total system, and refrigeration system; and verification test; 1996 nendo chodendo denryoku oyo gijutsu kaihatsu seika hokokusho. 1. Chodendo senzai no kenkyu kaihatsu, chodendo hatsudenki no kenkyu kaihatsu, total system no kenkyu, reito system no kenkyu kaihatsu, jissho shiken

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-01

    In the research and development of superconducting wires, studies are conducted to increase the current capacity of NbTi and Nb{sub 3}Sn metal wires and to improve their properties, and to increase the current capacity of oxide materials and improve their performance making full use of the features of each manufacturing method. In the development of superconducting generators, a slow excitation response type is tested for verification, and a good result is attained; and a quick excitation response type is tested for field winding static excitation, and good performance is exhibited. Using the results so far achieved, the 200,000kW class pilot machine concept design is reviewed. In the study of total systems, feasibility is studied of a quench test for the 70,000kW class machine through simulation analyses, etc. In the development of refrigeration systems, efforts are exerted to improve on the conventional type in terms of reliability and to further improve on the improved version in terms of performance and space-saving feature. One of the endeavors involves the development of a He Brayton cycle turbine driven compressor. A multilayer cylindrical rotor is verified in terms of functions, characteristics, reliability and durability, and various data are collected toward the development of a pilot machine. (NEDO)

  6. Verification testing of the compression performance of the HEVC screen content coding extensions

    Science.gov (United States)

    Sullivan, Gary J.; Baroncini, Vittorio A.; Yu, Haoping; Joshi, Rajan L.; Liu, Shan; Xiu, Xiaoyu; Xu, Jizheng

    2017-09-01

    This paper reports on verification testing of the coding performance of the screen content coding (SCC) extensions of the High Efficiency Video Coding (HEVC) standard (Rec. ITU-T H.265 | ISO/IEC 23008-2 MPEG-H Part 2). The coding performance of HEVC screen content model (SCM) reference software is compared with that of the HEVC test model (HM) without the SCC extensions, as well as with the Advanced Video Coding (AVC) joint model (JM) reference software, for both lossy and mathematically lossless compression using All-Intra (AI), Random Access (RA), and Lowdelay B (LB) encoding structures and using similar encoding techniques. Video test sequences in 1920×1080 RGB 4:4:4, YCbCr 4:4:4, and YCbCr 4:2:0 colour sampling formats with 8 bits per sample are tested in two categories: "text and graphics with motion" (TGM) and "mixed" content. For lossless coding, the encodings are evaluated in terms of relative bit-rate savings. For lossy compression, subjective testing was conducted at 4 quality levels for each coding case, and the test results are presented through mean opinion score (MOS) curves. The relative coding performance is also evaluated in terms of Bjøntegaard-delta (BD) bit-rate savings for equal PSNR quality. The perceptual tests and objective metric measurements show a very substantial benefit in coding efficiency for the SCC extensions, and provided consistent results with a high degree of confidence. For TGM video, the estimated bit-rate savings ranged from 60-90% relative to the JM and 40-80% relative to the HM, depending on the AI/RA/LB configuration category and colour sampling format.

  7. Language Testing and Technology: Past and Future.

    Science.gov (United States)

    Chalhoub-Deville, Micheline

    2001-01-01

    Reflects on what has transpired in the second language (L2) testing field in relation to technology and situates developments within the larger language testing, general measurement, and educational contexts. (Author/VWL)

  8. Verification of experimental modal modeling using HDR (Heissdampfreaktor) dynamic test data

    International Nuclear Information System (INIS)

    Srinivasan, M.G.; Kot, C.A.; Hsieh, B.J.

    1983-01-01

    Experimental modal modeling involves the determination of the modal parameters of the model of a structure from recorded input-output data from dynamic tests. Though commercial modal analysis algorithms are being widely used in many industries their ability to identify a set of reliable modal parameters of an as-built nuclear power plant structure has not been systematically verified. This paper describes the effort to verify MODAL-PLUS, a widely used modal analysis code, using recorded data from the dynamic tests performed on the reactor building of the Heissdampfreaktor, situated near Frankfurt, Federal Republic of Germany. In the series of dynamic tests on HDR in 1979, the reactor building was subjected to forced vibrations from different types and levels of dynamic excitations. Two sets of HDR containment building input-output data were chosen for MODAL-PLUS analyses. To reduce the influence of nonlinear behavior on the results, these sets were chosen so that the levels of excitation are relatively low and about the same in the two sets. The attempted verification was only partially successful in that only one modal model, with a limited range of validity, could be synthesized and in that the goodness of fit could be verified only in this limited range

  9. Measuring Software Test Verification for Complex Workpieces based on Virtual Gear Measuring Instrument

    Directory of Open Access Journals (Sweden)

    Yin Peili

    2017-08-01

    Full Text Available Validity and correctness test verification of the measuring software has been a thorny issue hindering the development of Gear Measuring Instrument (GMI. The main reason is that the software itself is difficult to separate from the rest of the measurement system for independent evaluation. This paper presents a Virtual Gear Measuring Instrument (VGMI to independently validate the measuring software. The triangular patch model with accurately controlled precision was taken as the virtual workpiece and a universal collision detection model was established. The whole process simulation of workpiece measurement is implemented by VGMI replacing GMI and the measuring software is tested in the proposed virtual environment. Taking involute profile measurement procedure as an example, the validity of the software is evaluated based on the simulation results; meanwhile, experiments using the same measuring software are carried out on the involute master in a GMI. The experiment results indicate a consistency of tooth profile deviation and calibration results, thus verifying the accuracy of gear measuring system which includes the measurement procedures. It is shown that the VGMI presented can be applied in the validation of measuring software, providing a new ideal platform for testing of complex workpiece-measuring software without calibrated artifacts.

  10. Material integrity verification radar

    International Nuclear Information System (INIS)

    Koppenjan, S.K.

    1999-01-01

    The International Atomic Energy Agency (IAEA) has the need for verification of 'as-built' spent fuel-dry storage containers and other concrete structures. The IAEA has tasked the Special Technologies Laboratory (STL) to fabricate, test, and deploy a stepped-frequency Material Integrity Verification Radar (MIVR) system to nondestructively verify the internal construction of these containers. The MIVR system is based on previously deployed high-frequency, ground penetrating radar (GPR) systems that have been developed by STL for the U.S. Department of Energy (DOE). Whereas GPR technology utilizes microwave radio frequency energy to create subsurface images, MTVR is a variation for which the medium is concrete instead of soil. The purpose is to nondestructively verify the placement of concrete-reinforcing materials, pipes, inner liners, and other attributes of the internal construction. The MIVR system underwent an initial field test on CANDU reactor spent fuel storage canisters at Atomic Energy of Canada Limited (AECL), Chalk River Laboratories, Ontario, Canada, in October 1995. A second field test at the Embalse Nuclear Power Plant in Embalse, Argentina, was completed in May 1996. The DOE GPR also was demonstrated at the site. Data collection and analysis were performed for the Argentine National Board of Nuclear Regulation (ENREN). IAEA and the Brazilian-Argentine Agency for the Control and Accounting of Nuclear Material (ABACC) personnel were present as observers during the test. Reinforcing materials were evident in the color, two-dimensional images produced by the MIVR system. A continuous pattern of reinforcing bars was evident and accurate estimates on the spacing, depth, and size were made. The potential uses for safeguard applications were jointly discussed. The MIVR system, as successfully demonstrated in the two field tests, can be used as a design verification tool for IAEA safeguards. A deployment of MIVR for Design Information Questionnaire (DIQ

  11. SRS environmental technology development field test platform

    International Nuclear Information System (INIS)

    Riha, B.D.; Rossabi, J.; Eddy-Dilek, C.A.

    1995-01-01

    A critical and difficult step in the development and implementation of new technologies for environmental monitoring and characterization is successfully transferring these technologies to industry and government users for routine assessment and compliance activities. The Environmental Sciences Section of the DOE Savannah River Technology Center provides a forum for developers, potential users, and regulatory organizations to evaluate new technologies in comparison with baseline technologies in a well characterized field test bed. The principal objective of this project is to conduct comprehensive, objective field tests of monitoring and characterization technologies that are not currently used in EPA standard methods and evaluate their performance during actual operating conditions against baseline methods. This paper provides an overview of the field test site and a description of some of the technologies demonstrated at the site including their field applications

  12. VERIFICATION TESTING OF EMISSIONS FROM THE COMBUSTION OF A-55 CLEAN FUELS IN A FIRETUBE BOILER

    Science.gov (United States)

    The report gives results of testing three fuels in a small (732 kW) firetube package boiler to determine emissions of carbon monoxide (CO), nitrogen oxide (NO), particulate matter (PM), and total hydrocarbons (THCs). The tests were part of EPA's Environmental Technology Verificat...

  13. Validation and Verification (V and V) Testing on Midscale Flame Resistant (FR) Test Method

    Science.gov (United States)

    2016-12-16

    materials . The results demonstrated that the Midscale test is a quick and cost-effective method for evaluation of FR performance of design features...standard and novel FR materials and design configurations during fire engulfment. Details of the test method and its development can be found in the...employed in the FRACU is a ripstop fabric blend of 65% FR rayon, 25% para- aramid and 10% nylon. The iCVC material is Nylon/Cotton/Nomex. All three

  14. A two-dimensional liquid-filled ionization chamber array prototype for small-field verification: characterization and first clinical tests

    International Nuclear Information System (INIS)

    Brualla-González, Luis; Vicedo, Aurora; Roselló, Joan V; Gómez, Faustino; González-Castaño, Diego M; Gago-Arias, Araceli; Pazos, Antonio; Zapata, Martín; Pardo-Montero, Juan

    2012-01-01

    In this work we present the design, characterization and first clinical tests of an in-house developed two-dimensional liquid-filled ionization chamber prototype for the verification of small radiotherapy fields and treatments containing such small fields as in radiosurgery, which consists of 2 mm × 2 mm pixels arranged on a 16×8 rectangular grid. The ionization medium is isooctane. The characterization of the device included the study of depth, field-size and dose-rate dependences, which are sufficiently moderate for a good operation at therapy radiation levels. However, the detector presents an important anisotropic response, up to ≃ 12% for front versus near-lateral incidence, which can impact the verification of full treatments with different incidences. In such a case, an anisotropy correction factor can be applied. Output factors of small square fields measured with the device show a small systematic over-response, less than 1%, when compared to unshielded diode measurements. An IMRT radiosurgery treatment has been acquired with the liquid-filled ionization chamber device and compared with film dosimetry by using the gamma method, showing good agreement: over 99% passing rates for 1.2% and 1.2 mm for an incidence-per-incidence analysis; 100% passing rates for tolerances 1.8% and 1.8 mm when the whole treatment is analysed and the anisotropy correction factor is applied. The point dose verification for each incidence of the treatment performed with the liquid-filled ionization chamber agrees within 1% with a CC01 ionization chamber. This prototype has shown the utility of this kind of technology for the verification of small fields/treatments. Currently, a larger device covering a 5 cm × 5 cm area is under development. (paper)

  15. Case Study: Test Results of a Tool and Method for In-Flight, Adaptive Control System Verification on a NASA F-15 Flight Research Aircraft

    Science.gov (United States)

    Jacklin, Stephen A.; Schumann, Johann; Guenther, Kurt; Bosworth, John

    2006-01-01

    Adaptive control technologies that incorporate learning algorithms have been proposed to enable autonomous flight control and to maintain vehicle performance in the face of unknown, changing, or poorly defined operating environments [1-2]. At the present time, however, it is unknown how adaptive algorithms can be routinely verified, validated, and certified for use in safety-critical applications. Rigorous methods for adaptive software verification end validation must be developed to ensure that. the control software functions as required and is highly safe and reliable. A large gap appears to exist between the point at which control system designers feel the verification process is complete, and when FAA certification officials agree it is complete. Certification of adaptive flight control software verification is complicated by the use of learning algorithms (e.g., neural networks) and degrees of system non-determinism. Of course, analytical efforts must be made in the verification process to place guarantees on learning algorithm stability, rate of convergence, and convergence accuracy. However, to satisfy FAA certification requirements, it must be demonstrated that the adaptive flight control system is also able to fail and still allow the aircraft to be flown safely or to land, while at the same time providing a means of crew notification of the (impending) failure. It was for this purpose that the NASA Ames Confidence Tool was developed [3]. This paper presents the Confidence Tool as a means of providing in-flight software assurance monitoring of an adaptive flight control system. The paper will present the data obtained from flight testing the tool on a specially modified F-15 aircraft designed to simulate loss of flight control faces.

  16. MO-F-16A-01: Implementation of MPPG TPS Verification Tests On Various Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Smilowitz, J; Bredfeldt, J; Geurts, M; Miller, J [University of Wisconsin, Madison, WI (United States)

    2014-06-15

    Purpose: To demonstrate the implementation of the Medical Physics Practice Guideline (MPPG) for dose calculation and beam parameters verification of treatment planning systems (TPS). Methods: We implemented the draft TPS MPPG for three linacs: Varian Trilogy, TomoHDA and Elekta Infinity. Static and modulated test plans were created. The static fields are different than used in commissioning. Data was collected using ion chambers and diodes in a scanning water tank, Delta4 phantom and a custom phantom. MatLab and Microsoft Excel were used to create analysis tools to compare reference DICOM dose with scan data. This custom code allowed for the interpolation, registration and gamma analysis of arbitrary dose profiles. It will be provided as open source code. IMRT fields were validated with Delta4 registration and comparison tools. The time for each task was recorded. Results: The tests confirmed the strengths, and revealed some limitations, of our TPS. The agreement between calculated and measured dose was reported for all beams. For static fields, percent depth dose and profiles were analyzed with criteria in the draft MPPG. The results reveal areas of slight mismatch with the model (MLC leaf penumbra, buildup region.) For TomoTherapy, the IMRT plan 2%/2 mm gamma analysis revealed poorest agreement in the low dose regions. For one static test plan for all 10MV Trilogy photon beams, the plan generation, scan queue creation, data collection, data analysis and report took 2 hours, excluding tank setup. Conclusions: We have demonstrated the implementation feasibility of the TPS MPPG. This exercise generated an open source tool for dose comparisons between scan data and DICOM dose data. An easily reproducible and efficient infrastructure with streamlined data collection was created for repeatable robust testing of the TPS. The tests revealed minor discrepancies in our models and areas for improvement that are being investigated.

  17. MO-F-16A-01: Implementation of MPPG TPS Verification Tests On Various Accelerators

    International Nuclear Information System (INIS)

    Smilowitz, J; Bredfeldt, J; Geurts, M; Miller, J

    2014-01-01

    Purpose: To demonstrate the implementation of the Medical Physics Practice Guideline (MPPG) for dose calculation and beam parameters verification of treatment planning systems (TPS). Methods: We implemented the draft TPS MPPG for three linacs: Varian Trilogy, TomoHDA and Elekta Infinity. Static and modulated test plans were created. The static fields are different than used in commissioning. Data was collected using ion chambers and diodes in a scanning water tank, Delta4 phantom and a custom phantom. MatLab and Microsoft Excel were used to create analysis tools to compare reference DICOM dose with scan data. This custom code allowed for the interpolation, registration and gamma analysis of arbitrary dose profiles. It will be provided as open source code. IMRT fields were validated with Delta4 registration and comparison tools. The time for each task was recorded. Results: The tests confirmed the strengths, and revealed some limitations, of our TPS. The agreement between calculated and measured dose was reported for all beams. For static fields, percent depth dose and profiles were analyzed with criteria in the draft MPPG. The results reveal areas of slight mismatch with the model (MLC leaf penumbra, buildup region.) For TomoTherapy, the IMRT plan 2%/2 mm gamma analysis revealed poorest agreement in the low dose regions. For one static test plan for all 10MV Trilogy photon beams, the plan generation, scan queue creation, data collection, data analysis and report took 2 hours, excluding tank setup. Conclusions: We have demonstrated the implementation feasibility of the TPS MPPG. This exercise generated an open source tool for dose comparisons between scan data and DICOM dose data. An easily reproducible and efficient infrastructure with streamlined data collection was created for repeatable robust testing of the TPS. The tests revealed minor discrepancies in our models and areas for improvement that are being investigated

  18. Structural identification of short/middle span bridges by rapid impact testing: theory and verification

    International Nuclear Information System (INIS)

    Zhang, Jian; Wu, Z S; Zhang, Q Q; Guo, S L; Xu, D W

    2015-01-01

    A structural strain flexibility identification method by processing the multiple-reference impact testing data is proposed. First, a kind of novel long-gauge fiber optic sensor is developed for structural macro-strain monitoring. Second, the multiple-reference impact testing technology is employed, during which both the impacting force and structural strain responses are measured. The impact testing technology has unique merit because it is able to extract exact structural frequency response functions (FRFs), while other test methods, for instance ambient tests, can only output the FRFs with scaled magnitudes. Most importantly, the originality of the article is that a method of identifying the structural strain flexibility characteristic from the impact test data has been proposed, which is useful for structural static strain prediction and capacity evaluation. Examples of a six meter simple supported beam and a multiple-span continuous beam bridge have successfully verified the effectiveness of the proposed method. (paper)

  19. Structural identification of short/middle span bridges by rapid impact testing: theory and verification

    Science.gov (United States)

    Zhang, Jian; Zhang, Q. Q.; Guo, S. L.; Xu, D. W.; Wu, Z. S.

    2015-06-01

    A structural strain flexibility identification method by processing the multiple-reference impact testing data is proposed. First, a kind of novel long-gauge fiber optic sensor is developed for structural macro-strain monitoring. Second, the multiple-reference impact testing technology is employed, during which both the impacting force and structural strain responses are measured. The impact testing technology has unique merit because it is able to extract exact structural frequency response functions (FRFs), while other test methods, for instance ambient tests, can only output the FRFs with scaled magnitudes. Most importantly, the originality of the article is that a method of identifying the structural strain flexibility characteristic from the impact test data has been proposed, which is useful for structural static strain prediction and capacity evaluation. Examples of a six meter simple supported beam and a multiple-span continuous beam bridge have successfully verified the effectiveness of the proposed method.

  20. Empirical Tests and Preliminary Results with the Krakatoa Tool for Full Static Program Verification

    Directory of Open Access Journals (Sweden)

    Ramírez-de León Edgar Darío

    2014-10-01

    Full Text Available XJML (Ramírez et al., 2012 is a modular external platform for Verification and Validation of Java classes using the Java Modeling Language (JML through contracts written in XML. One problem faced in the XJML development was how to integrate Full Static Program Verification (FSPV. This paper presents the experiments and results that allowed us to define what tool to embed in XJML to execute FSPV.

  1. Battery algorithm verification and development using hardware-in-the-loop testing

    Energy Technology Data Exchange (ETDEWEB)

    He, Yongsheng [General Motors Global Research and Development, 30500 Mound Road, MC 480-106-252, Warren, MI 48090 (United States); Liu, Wei; Koch, Brain J. [General Motors Global Vehicle Engineering, Warren, MI 48090 (United States)

    2010-05-01

    Battery algorithms play a vital role in hybrid electric vehicles (HEVs), plug-in hybrid electric vehicles (PHEVs), extended-range electric vehicles (EREVs), and electric vehicles (EVs). The energy management of hybrid and electric propulsion systems needs to rely on accurate information on the state of the battery in order to determine the optimal electric drive without abusing the battery. In this study, a cell-level hardware-in-the-loop (HIL) system is used to verify and develop state of charge (SOC) and power capability predictions of embedded battery algorithms for various vehicle applications. Two different batteries were selected as representative examples to illustrate the battery algorithm verification and development procedure. One is a lithium-ion battery with a conventional metal oxide cathode, which is a power battery for HEV applications. The other is a lithium-ion battery with an iron phosphate (LiFePO{sub 4}) cathode, which is an energy battery for applications in PHEVs, EREVs, and EVs. The battery cell HIL testing provided valuable data and critical guidance to evaluate the accuracy of the developed battery algorithms, to accelerate battery algorithm future development and improvement, and to reduce hybrid/electric vehicle system development time and costs. (author)

  2. Battery algorithm verification and development using hardware-in-the-loop testing

    Science.gov (United States)

    He, Yongsheng; Liu, Wei; Koch, Brain J.

    Battery algorithms play a vital role in hybrid electric vehicles (HEVs), plug-in hybrid electric vehicles (PHEVs), extended-range electric vehicles (EREVs), and electric vehicles (EVs). The energy management of hybrid and electric propulsion systems needs to rely on accurate information on the state of the battery in order to determine the optimal electric drive without abusing the battery. In this study, a cell-level hardware-in-the-loop (HIL) system is used to verify and develop state of charge (SOC) and power capability predictions of embedded battery algorithms for various vehicle applications. Two different batteries were selected as representative examples to illustrate the battery algorithm verification and development procedure. One is a lithium-ion battery with a conventional metal oxide cathode, which is a power battery for HEV applications. The other is a lithium-ion battery with an iron phosphate (LiFePO 4) cathode, which is an energy battery for applications in PHEVs, EREVs, and EVs. The battery cell HIL testing provided valuable data and critical guidance to evaluate the accuracy of the developed battery algorithms, to accelerate battery algorithm future development and improvement, and to reduce hybrid/electric vehicle system development time and costs.

  3. A framework for nuclear agreement and verification

    International Nuclear Information System (INIS)

    Ali, A.

    1991-01-01

    This chapter assesses the prospects for a nuclear agreement between India and Pakistan. The chapter opens with a review of past and present political environments of the two countries. The discussion proceeds to describe the linkage of global arms control agreements, prospects for verification of a Comprehensive Test Ban Treaty, the role of nuclear power in any agreements, the intrusiveness of verification, and possible post-proliferation agreements. Various monitoring and verification technologies are described (mainly satellite oriented). The chapter concludes with an analysis of the likelihood of persuading India and Pakistan to agree to a nonproliferation arrangement

  4. Development and verification test of integral reactor major components - Development of MCP impeller design, performance prediction code and experimental verification

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Myung Kyoon; Oh, Woo Hyoung; Song, Jae Wook [Korea Advanced Institute of Science and Technology, Taejon (Korea)

    1999-03-01

    The present study is aimed at developing a computational code for design and performance prediction of an axial-flow pump. The proposed performance prediction method is tested against a model axial-flow pump streamline curvature method. The preliminary design is made by using the ideal velocity triangles at inlet and exit and the three dimensional blade shape is calculated by employing the free vortex design method. Then the detailed blading design is carried out by using experimental database of double circular arc cambered hydrofoils. To computationally determine the design incidence, deviation, blade camber, solidity and stagger angle, a number of correlation equations are developed form the experimental database and a theorical formula for the lift coefficient is adopted. A total of 8 equations are solved iteratively using an under-relaxation factor. An experimental measurement is conducted under a non-cavitating condition to obtain the off-design performance curve and also a cavitation test is carried out by reducing the suction pressure. The experimental results are very satisfactorily compared with the predictions by the streamline curvature method. 28 refs., 26 figs., 11 tabs. (Author)

  5. Utterance Verification for Text-Dependent Speaker Recognition

    DEFF Research Database (Denmark)

    Kinnunen, Tomi; Sahidullah, Md; Kukanov, Ivan

    2016-01-01

    Text-dependent automatic speaker verification naturally calls for the simultaneous verification of speaker identity and spoken content. These two tasks can be achieved with automatic speaker verification (ASV) and utterance verification (UV) technologies. While both have been addressed previously...

  6. Verification test of advanced LWR fuel components of Westinghouse type nuclear power plants

    International Nuclear Information System (INIS)

    Kim, Hyung Kyu; Yoon, Kyung Ho; Lee, Young Ho

    2004-08-01

    The purpose of this project is to independently conduct the performance test of the spacer grids and the cladding material of the 16x16 and 17x17 advanced fuels for Westinghouse type plants, and to improve the relevant test technology. Major works and results of the present research are as follows. 1. The design and structural features of the spacer grids were investigated, especially the finally determined I-spring was thoroughly analyzed in the point of the mechanical damage and characteristic. 2. As for the mechanical tests of the space grids, the characterization, the impact and the fretting wear tests were carried out. The block as well as the in-grid tests were conducted for the spring/dimple characterization, from which a simple method was developed that simulated the boundary conditions of the assembled grid straps. The impact tester was modified and improved to accommodate a full size grid assembly. The impact result showed that the grid assembly fulfilled the design criteria. As for the fretting wear tests, a sliding test under the room temperature air/water, a sliding/impact test under the room temperature air and a sliding/impact tests under the high temperature and pressure environments were carried out. To this end, a high temperature and pressure fretting wear tester was newly developed. The wear characteristic and the resistibility of the advanced grid spring/dimple were analyzed in detail. The test results were verified through comparing those with the test results by the Westinghouse company. 3. The properties and performance of the newly adopted material for the cladding, Low Sn Zirlo was investigated by a room and high temperature tensile tests and a corrosion tests under the environments of 360 .deg. C water, 400 steam and 360 .deg. C 70ppm LiOH. Through the present project, all the test equipment and technologies for the fuel components were procured, which will be used for future domestic development of a new fuel

  7. Microelectronic test structures for CMOS technology

    CERN Document Server

    Ketchen, Mark B

    2011-01-01

    Microelectronic Test Structures for CMOS Technology and Products addresses the basic concepts of the design of test structures for incorporation within test-vehicles, scribe-lines, and CMOS products. The role of test structures in the development and monitoring of CMOS technologies and products has become ever more important with the increased cost and complexity of development and manufacturing. In this timely volume, IBM scientists Manjul Bhushan and Mark Ketchen emphasize high speed characterization techniques for digital CMOS circuit applications and bridging between circuit performance an

  8. Some New Verification Test Problems for Multimaterial Diffusion on Meshes that are Non-Aligned with Material Boundaries

    Energy Technology Data Exchange (ETDEWEB)

    Dawes, Alan Sidney [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Malone, Christopher M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Shashkov, Mikhail Jurievich [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-07-07

    In this report a number of new verification test problems for multimaterial diffusion will be shown. Using them we will show that homogenization of multimaterial cells in either Arbitrary Lagrangian Eulerian (ALE) or Eulerian simulations can lead to errors in the energy flow at the interfaces. Results will be presented that show that significant improvements and predictive capability can be gained by using either a surrogate supermesh, such as Thin Mesh in FLAG, or the emerging method based on Static Condensation.

  9. Challenges for effective WMD verification

    International Nuclear Information System (INIS)

    Andemicael, B.

    2006-01-01

    Effective verification is crucial to the fulfillment of the objectives of any disarmament treaty, not least as regards the proliferation of weapons of mass destruction (WMD). The effectiveness of the verification package depends on a number of factors, some inherent in the agreed structure and others related to the type of responses demanded by emerging challenges. The verification systems of three global agencies-the IAEA, the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO, currently the Preparatory Commission), and the Organization for the Prohibition of Chemical Weapons (OPCW)-share similarities in their broad objectives of confidence-building and deterrence by assuring members that rigorous verification would deter or otherwise detect non-compliance. Yet they are up against various constraints and other issues, both internal and external to the treaty regime. These constraints pose major challenges to the effectiveness and reliability of the verification operations. In the nuclear field, the IAEA safeguards process was the first to evolve incrementally from modest Statute beginnings to a robust verification system under the global Treaty on the Non-Proliferation of Nuclear Weapons (NPT). The nuclear non-proliferation regime is now being supplemented by a technology-intensive verification system of the nuclear test-ban treaty (CTBT), a product of over three decades of negotiation. However, there still remain fundamental gaps and loopholes in the regime as a whole, which tend to diminish the combined effectiveness of the IAEA and the CTBT verification capabilities. He three major problems are (a) the lack of universality of membership, essentially because of the absence of three nuclear weapon-capable States-India, Pakistan and Israel-from both the NPT and the CTBT, (b) the changes in US disarmament policy, especially in the nuclear field, and (c) the failure of the Conference on Disarmament to conclude a fissile material cut-off treaty. The world is

  10. Transport Network Technologies – Study and Testing

    DEFF Research Database (Denmark)

    Bozorgebrahimi, K.; Channegowda, M.; Colmenero, A.

    Following on from the theoretical research into Carrier Class Transport Network Technologies (CCTNTs) documented in DJ1.1.1, this report describes the extensive testing performed by JRA1 Task 1. The tests covered EoMPLS, Ethernet OAM, Synchronous Ethernet, PBB-TE, MPLS-TP, OTN and GMPLS...

  11. Design, Fabrication and Test Report on a Verification Capsule (05M-06K) for the Control of a Neutron Irradiation Fluence of Specimens in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Choo, K. N.; Kim, B. G.; Kang, Y. H.; Cho, M. S.; Son, J. M.; Shin, Y. T.; Park, S. J.; Choi, M. H.; Lee, D. S.

    2007-02-15

    As a part of a project for a capsule development and utilization for an irradiation test, a verification capsule (05M-06K) was designed, fabricated and tested for the development of new instrumented capsule technology for a more precise control of the irradiation fluence of a specimen, irrespective of the reactor operation condition. The basic structure of the 05M-06K capsule was based on the 04M-22K mock-up capsule which was successfully designed and out-pile tested to confirm the various key technologies necessary for the fluence control of a specimen. 21 square and round shaped specimens made of STS 304 were inserted into the capsule. The capsule was constructed in 5 stages with specimens and an independent electric heater at each stage. Each of the five specimens which were accommodated in the 1st stage (top) of the capsule can be taken out of the HANARO core during a normal reactor operation. The specimen is extracted by a specimen extraction mechanism using a steel wire. During the out-pile test, the temperatures of the specimens were measured by 12 thermocouples installed in the capsule. The capsule was successfully out-pile tested in a single channel test loop. The obtained results will be used for a safety evaluation of the new irradiation capsule for controlling the irradiation fluence of specimens in HANARO.

  12. Academic Self-Esteem and Perceived Validity of Grades: A Test of Self-Verification Theory.

    Science.gov (United States)

    Okun, Morris A.; Fournet, Lee M.

    1993-01-01

    The hypothesis derived from self-verification theory that semester grade point average would be positively related to perceived validity of grade scores among high self-esteem undergraduates and inversely related for low self-esteem students was not supported in a study with 281 undergraduates. (SLD)

  13. Current Status of Aerosol Generation and Measurement Facilities for the Verification Test of Containment Filtered Venting System in KAERI

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Il; An, Sang Mo; Ha, Kwang Soon; Kim, Hwan Yeol [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    In this study, the design of aerosol generation and measurement systems are explained and present circumstances are also described. In addition, the aerosol test plan is shown. Containment Filtered Venting System (FCVS) is one of the safety features to reduce the amount of released fission product into the environment by depressurizing the containment. Since Chernobyl accident, the regulatory agency in several countries in Europe such as France, Germany, Sweden, etc. have been demanded the installation of the CFVS. Moreover, the feasibility study on the CFVS was also performed in U.S. After the Fukushima accident, there is a need to improve a containment venting or installation of depressurizing facility in Korea. As a part of a Ministry of Trade, Industry and Energy (MOTIE) project, KAERI has been conducted the integrated performance verification test of CFVS. As a part of the test, aerosol generation system and measurement systems were designed to simulate the fission products behavior. To perform the integrated verification test of CFVS, aerosol generation and measurement system was designed and manufactured. The component operating condition is determined to consider the severe accident condition. The test will be performed in normal conditions at first, and will be conducted under severe condition, high pressure and high temperature. Undesirable difficulties which disturb the elaborate test are expected, such as thermophoresis on the pipe, vapor condensation on aerosol, etc.

  14. Verification survey report of the south waste tank farm training/test tower and hazardous waste storage lockers at the West Valley demonstration project, West Valley, New York

    International Nuclear Information System (INIS)

    Weaver, Phyllis C.

    2012-01-01

    A team from ORAU's Independent Environmental Assessment and Verification Program performed verification survey activities on the South Test Tower and four Hazardous Waste Storage Lockers. Scan data collected by ORAU determined that both the alpha and alpha-plus-beta activity was representative of radiological background conditions. The count rate distribution showed no outliers that would be indicative of alpha or alpha-plus-beta count rates in excess of background. It is the opinion of ORAU that independent verification data collected support the site's conclusions that the South Tower and Lockers sufficiently meet the site criteria for release to recycle and reuse

  15. Testing, verification and application of CONTAIN for severe accident analysis of LMFBR-containments

    International Nuclear Information System (INIS)

    Langhans, J.

    1991-01-01

    Severe accident analysis for LMFBR-containments has to consider various phenomena influencing the development of containment loads as pressure and temperatures as well as generation, transport, depletion and release of aerosols and radioactive materials. As most of the different phenomena are linked together their feedback has to be taken into account within the calculation of severe accident consequences. Otherwise no best-estimate results can be assured. Under the sponsorship of the German BMFT the US code CONTAIN is being developed, verified and applied in GRS for future fast breeder reactor concepts. In the first step of verification, the basic calculation models of a containment code have been proven: (i) flow calculation for different flow situations, (ii) heat transfer from and to structures, (iii) coolant evaporation, boiling and condensation, (iv) material properties. In the second step the proof of the interaction of coupled phenomena has been checked. The calculation of integrated containment experiments relating natural convection flow, structure heating and coolant condensation as well as parallel calculation of results obtained with an other code give detailed information on the applicability of CONTAIN. The actual verification status allows the following conclusion: a caucious analyst experienced in containment accident modelling using the proven parts of CONTAIN will obtain results which have the same accuracy as other well optimized and detailed lumped parameter containment codes can achieve. Further code development, additional verification and international exchange of experience and results will assure an adequate code for the application in safety analyses for LMFBRs. (orig.)

  16. Night vision imaging system design, integration and verification in spacecraft vacuum thermal test

    Science.gov (United States)

    Shang, Yonghong; Wang, Jing; Gong, Zhe; Li, Xiyuan; Pei, Yifei; Bai, Tingzhu; Zhen, Haijing

    2015-08-01

    The purposes of spacecraft vacuum thermal test are to characterize the thermal control systems of the spacecraft and its component in its cruise configuration and to allow for early retirement of risks associated with mission-specific and novel thermal designs. The orbit heat flux is simulating by infrared lamp, infrared cage or electric heater. As infrared cage and electric heater do not emit visible light, or infrared lamp just emits limited visible light test, ordinary camera could not operate due to low luminous density in test. Moreover, some special instruments such as satellite-borne infrared sensors are sensitive to visible light and it couldn't compensate light during test. For improving the ability of fine monitoring on spacecraft and exhibition of test progress in condition of ultra-low luminous density, night vision imaging system is designed and integrated by BISEE. System is consist of high-gain image intensifier ICCD camera, assistant luminance system, glare protect system, thermal control system and computer control system. The multi-frame accumulation target detect technology is adopted for high quality image recognition in captive test. Optical system, mechanical system and electrical system are designed and integrated highly adaptable to vacuum environment. Molybdenum/Polyimide thin film electrical heater controls the temperature of ICCD camera. The results of performance validation test shown that system could operate under vacuum thermal environment of 1.33×10-3Pa vacuum degree and 100K shroud temperature in the space environment simulator, and its working temperature is maintains at 5° during two-day test. The night vision imaging system could obtain video quality of 60lp/mm resolving power.

  17. APPLICATION OF STEEL PIPE PILE LOADING TESTS TO DESIGN VERIFICATION OF FOUNDATION OF THE TOKYO GATE BRIDGE

    Science.gov (United States)

    Saitou, Yutaka; Kikuchi, Yoshiaki; Kusakabe, Osamu; Kiyomiya, Osamu; Yoneyama, Haruo; Kawakami, Taiji

    Steel sheet pipe pile foundations with large diameter steel pipe sheet pile were used for the foundation of the main pier of the Tokyo Gateway bridge. However, as for the large diameter steel pipe pile, the bearing mechanism including a pile tip plugging effect is still unclear due to lack of the practical examinations even though loading tests are performed on Trans-Tokyo Bay Highway. In the light of the foregoing problems, static pile loading tests both vertical and horizontal directions, a dynamic loading test, and cone penetration tests we re conducted for determining proper design parameters of the ground for the foundations. Design parameters were determined rationally based on the tests results. Rational design verification was obtained from this research.

  18. Comparison of fingerprint and facial biometric verification technologies for user access and patient identification in a clinical environment

    Science.gov (United States)

    Guo, Bing; Zhang, Yu; Documet, Jorge; Liu, Brent; Lee, Jasper; Shrestha, Rasu; Wang, Kevin; Huang, H. K.

    2007-03-01

    As clinical imaging and informatics systems continue to integrate the healthcare enterprise, the need to prevent patient mis-identification and unauthorized access to clinical data becomes more apparent especially under the Health Insurance Portability and Accountability Act (HIPAA) mandate. Last year, we presented a system to track and verify patients and staff within a clinical environment. This year, we further address the biometric verification component in order to determine which Biometric system is the optimal solution for given applications in the complex clinical environment. We install two biometric identification systems including fingerprint and facial recognition systems at an outpatient imaging facility, Healthcare Consultation Center II (HCCII). We evaluated each solution and documented the advantages and pitfalls of each biometric technology in this clinical environment.

  19. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT - FIELD PORTABLE GAS CHROMATOGRAPH/MASS SPECTROMETER - VIKING INSTRUMENTS CORPORATION

    Science.gov (United States)

    The performance evaluation of innovative and alternative environmental technologies is an integral part of the U.S. Environmental Protection Agency's (EPA) mission. Early efforts focused on evaluation technologies that supported the implementation of the Clean Air and Clean Wate...

  20. Reliability test for reactor internals rejuvenation technology

    International Nuclear Information System (INIS)

    Uchiyama, Junichi

    1998-01-01

    41 transparencies were presented on the subject of 'Reliability test for reactor internals rejuvenation technology'. The items presented give an introduction on the management of plant life in Japan and introduce the Nuclear Power Engineering Corporation (NUPEC). The question of what reliability tests for rejuvenation of reactor internals are is discussed in some detail and an outline of each test is given. Altogether six methods to rejuvenate reactor internals are presented, two of which have already been applied to actual plants. The presentation was supported by many detailed drawings and images

  1. Installation with magnetic suspension of test bodies for measurement of small forces. Verification of equivalence of inertial and gravitational mass

    International Nuclear Information System (INIS)

    Kalebin, S.M.

    1988-01-01

    Torsion installation with magnetic suspension of test bodies for detection of small forces is considered. Installation application for verification of equivalence of inertial and gravitational mass in the case of test body incidence on the Earth (Etvesh experiment) and in the case of their incidene on the Sun (Dicke experiment) is discussed. The total mass of test bodies, produced in the form of cylinders with 3 cm radius, equals 50 kg (one lead body and one copper body); beam radius of test bodies equals 3 cm (the cylinders are tight against one another); ferrite cylinder with 3 cm radius and 10 cm height is used for their suspension in magnetic field. Effect of thermal noise and electromagnetic force disturbances on measurement results is considered. Conducted calculations show that suggested installation enables to improve the accuracy of verifying mentioned equivalence at least by one order and upwards. This suggests that such installation is a matter of interest for experiments on small force detection

  2. Historical hydronuclear testing: Characterization and remediation technologies

    International Nuclear Information System (INIS)

    Shaulis, L.; Wilson, G.; Jacobson, R.

    1997-09-01

    This report examines the most current literature and information available on characterization and remediation technologies that could be used on the Nevada Test Site (NTS) historical hydronuclear test areas. Historical hydronuclear tests use high explosives and a small amount of plutonium. The explosion scatters plutonium within a contained subsurface environment. There is currently a need to characterize these test areas to determine the spatial extent of plutonium in the subsurface and whether geohydrologic processes are transporting the plutonium away from the event site. Three technologies were identified to assist in the characterization of the sites. These technologies are the Pipe Explorer trademark, cone penetrometer, and drilling. If the characterization results indicate that remediation is needed, three remediation technologies were identified that should be appropriate, namely: capping or sealing the surface, in situ grouting, and in situ vitrification. Capping the surface would prevent vertical infiltration of water into the soil column, but would not restrict lateral movement of vadose zone water. Both the in situ grouting and vitrification techniques would attempt to immobilize the radioactive contaminants to restrict or prevent leaching of the radioactive contaminants into the groundwater. In situ grouting uses penetrometers or boreholes to inject the soil below the contaminant zone with low permeability grout. In situ vitrification melts the soil containing contaminants into a solid block. This technique would provide a significantly longer contaminant immobilization, but some research and development would be required to re-engineer existing systems for use at deep soil depths. Currently, equipment can only handle shallow depth vitrification. After existing documentation on the historical hydronuclear tests have been reviewed and the sites have been visited, more specific recommendations will be made

  3. Historical hydronuclear testing: Characterization and remediation technologies

    Energy Technology Data Exchange (ETDEWEB)

    Shaulis, L.; Wilson, G.; Jacobson, R.

    1997-09-01

    This report examines the most current literature and information available on characterization and remediation technologies that could be used on the Nevada Test Site (NTS) historical hydronuclear test areas. Historical hydronuclear tests use high explosives and a small amount of plutonium. The explosion scatters plutonium within a contained subsurface environment. There is currently a need to characterize these test areas to determine the spatial extent of plutonium in the subsurface and whether geohydrologic processes are transporting the plutonium away from the event site. Three technologies were identified to assist in the characterization of the sites. These technologies are the Pipe Explorer{trademark}, cone penetrometer, and drilling. If the characterization results indicate that remediation is needed, three remediation technologies were identified that should be appropriate, namely: capping or sealing the surface, in situ grouting, and in situ vitrification. Capping the surface would prevent vertical infiltration of water into the soil column, but would not restrict lateral movement of vadose zone water. Both the in situ grouting and vitrification techniques would attempt to immobilize the radioactive contaminants to restrict or prevent leaching of the radioactive contaminants into the groundwater. In situ grouting uses penetrometers or boreholes to inject the soil below the contaminant zone with low permeability grout. In situ vitrification melts the soil containing contaminants into a solid block. This technique would provide a significantly longer contaminant immobilization, but some research and development would be required to re-engineer existing systems for use at deep soil depths. Currently, equipment can only handle shallow depth vitrification. After existing documentation on the historical hydronuclear tests have been reviewed and the sites have been visited, more specific recommendations will be made.

  4. Optimized periodic verification testing blended risk and performance-based MOV inservice test program an application of ASME code case OMN-1

    Energy Technology Data Exchange (ETDEWEB)

    Sellers, C.; Fleming, K.; Bidwell, D.; Forbes, P. [and others

    1996-12-01

    This paper presents an application of ASME Code Case OMN-1 to the GL 89-10 Program at the South Texas Project Electric Generating Station (STPEGS). Code Case OMN-1 provides guidance for a performance-based MOV inservice test program that can be used for periodic verification testing and allows consideration of risk insights. Blended probabilistic and deterministic evaluation techniques were used to establish inservice test strategies including both test methods and test frequency. Described in the paper are the methods and criteria for establishing MOV safety significance based on the STPEGS probabilistic safety assessment, deterministic considerations of MOV performance characteristics and performance margins, the expert panel evaluation process, and the development of inservice test strategies. Test strategies include a mix of dynamic and static testing as well as MOV exercising.

  5. Optimized periodic verification testing blended risk and performance-based MOV inservice test program an application of ASME code case OMN-1

    International Nuclear Information System (INIS)

    Sellers, C.; Fleming, K.; Bidwell, D.; Forbes, P.

    1996-01-01

    This paper presents an application of ASME Code Case OMN-1 to the GL 89-10 Program at the South Texas Project Electric Generating Station (STPEGS). Code Case OMN-1 provides guidance for a performance-based MOV inservice test program that can be used for periodic verification testing and allows consideration of risk insights. Blended probabilistic and deterministic evaluation techniques were used to establish inservice test strategies including both test methods and test frequency. Described in the paper are the methods and criteria for establishing MOV safety significance based on the STPEGS probabilistic safety assessment, deterministic considerations of MOV performance characteristics and performance margins, the expert panel evaluation process, and the development of inservice test strategies. Test strategies include a mix of dynamic and static testing as well as MOV exercising

  6. Industrial Arts Test Development, Book III. Resource Items for Graphics Technology, Power Technology, Production Technology.

    Science.gov (United States)

    New York State Education Dept., Albany.

    This booklet is designed to assist teachers in developing examinations for classroom use. It is a collection of 955 objective test questions, mostly multiple choice, for industrial arts students in the three areas of graphics technology, power technology, and production technology. Scoring keys are provided. There are no copyright restrictions,…

  7. Technology transfer metrics: Measurement and verification of data/reusable launch vehicle business analysis

    Science.gov (United States)

    Trivoli, George W.

    1996-01-01

    Congress and the Executive Branch have mandated that all branches of the Federal Government exert a concentrated effort to transfer appropriate government and government contractor-developed technology to the industrial use in the U.S. economy. For many years, NASA has had a formal technology transfer program to transmit information about new technologies developed for space applications into the industrial or commercial sector. Marshall Space Flight Center (MSFC) has been in the forefront of the development of U.S. industrial assistance programs using technologies developed at the Center. During 1992-93, MSFC initiated a technology transfer metrics study. The MSFC study was the first of its kind among the various NASA centers. The metrics study is a continuing process, with periodic updates that reflect on-going technology transfer activities.

  8. Development of advanced-RCCA in PWR (2). Design of advanced-RCCA and verification test

    Energy Technology Data Exchange (ETDEWEB)

    Kitagawa, T.; Naitou, T.; Suzuki, S.; Kawahara, H. [Mitsubishi Heavy Industries Ltd., Kobe (Japan); Tanaka, T. [Kansai Electric Power Co., Inc. (Japan); Kuriyama, H. [Hokkaido Electric Power Co., Inc., Sapporo (Japan); Fujii, S. [Shikoku Electric Power Co., Inc., Takamatsu (Japan); Murakami, S. [Kyusyu Electric Power Co., Inc. (Japan); Murota, M. [Japan Atomic Power Co., Tokyo (Japan)

    2001-07-01

    Advanced-RCCA enhances control rod worth by adopting boron carbide (B{sub 4}C) with enriched {sup 10}B (hybrid structure B{sub 4}C/Ag-In-Cd). In APWR, advanced-RCCA result in the reduction of the number of RCCA. In conventional PWR, large MOX or high burn-up fuel loading could be introduced without the additional RCCAs. The duplex cladding structure with Cr plating on each outside surface increases the reliability against the RCCA-wear and results in reduction of inspection cost (inspection-equipment, and inspection-interval). Design of advanced-RCCA and verification are also discussed. (author)

  9. Burnup verification tests with the FORK measurement system-implementation for burnup credit

    International Nuclear Information System (INIS)

    Ewing, R.I.

    1994-01-01

    Verification measurements may be used to help ensure nuclear criticality safety when burnup credit is applied to spent fuel transport and storage systems. The FORK system measures the passive neutron and gamma-ray emission from spent fuel assemblies while in the storage pool. It was designed at Los Alamos National Laboratory for the International Atomic Energy Agency safeguards program and is well suited to verify burnup and cooling time records at commercial Pressurized Water Reactor (PWR) sites. This report deals with the application of the FORK system to burnup credit operations

  10. Formal Verification -26 ...

    Indian Academy of Sciences (India)

    by testing of the components and successful testing leads to the software being ... Formal verification is based on formal methods which are mathematically based ..... scenario under which a similar error could occur. There are various other ...

  11. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, REMOVAL OF ARSENIC IN DRINKING WATER: WATTS PREMIER M-SERIES M-15,000 REVERSE OSMOSIS TREATMENT SYSTEM

    Science.gov (United States)

    Verification testing of the Watts Premier M-Series M-15,000 RO Treatment System was conducted over a 31-day period from April 26, 2004, through May 26, 2004. This test was conducted at the Coachella Valley Water District (CVWD) Well 7802 in Thermal, California. The source water...

  12. Verification test for three WindCube WLS7 LiDARs at the Høvsøre test site

    DEFF Research Database (Denmark)

    Gottschall, Julia; Courtney, Michael

    The report describes the procedure of testing ground-based WindCube lidars (manufactured by the French company Leosphere) at the Høvsøre test site in comparison to reference sensors mounted at a meteorological mast. Results are presented for three tested units – in detail for unit WLS7-0062, and ......-0062, and in a summary for units WLS7-0064 and WLS7-0066. The verification test covers the evaluation of measured mean wind speeds, wind directions and wind speed standard deviations. The data analysis is basically performed in terms of different kinds of regression analyses.......The report describes the procedure of testing ground-based WindCube lidars (manufactured by the French company Leosphere) at the Høvsøre test site in comparison to reference sensors mounted at a meteorological mast. Results are presented for three tested units – in detail for unit WLS7...

  13. Reliability tests for reactor internals replacement technology

    International Nuclear Information System (INIS)

    Fujimaki, K.; Uchiyama, J.; Ohtsubo, T.

    2000-01-01

    Structural damage due to aging degradation of LWR reactor internals has been reported in several nuclear plants. NUPEC has started a project to test the reliability of the technology for replacing reactor internals, which was directed at preventive maintenance before damage and repair after damage for the aging degradation. The project has been funded by the Ministry of International Trade and Industry (MITI) of Japan since 1995, and it follows the policy of a report that the MITI has formally issued in April 1996 summarizing the countermeasures to be considered for aging nuclear plants and equipment. This paper gives an outline of the whole test plans and the test results for the BWR reactor internals replacement methods; core shroud, ICM housing, and CRD Housing and stub tube. The test results have shown that the methods were reliable and the structural integrity was appropriate based on the evaluation. (author)

  14. Verification of consumers' experiences and perceptions of genetic discrimination and its impact on utilization of genetic testing.

    Science.gov (United States)

    Barlow-Stewart, Kristine; Taylor, Sandra D; Treloar, Susan A; Stranger, Mark; Otlowski, Margaret

    2009-03-01

    To undertake a systematic process of verification of consumer accounts of alleged genetic discrimination. Verification of incidents reported in life insurance and other contexts that met the criteria of genetic discrimination, and the impact of fear of such treatment, was determined, with consent, through interview, document analysis and where appropriate, direct contact with the third party involved. The process comprised obtaining evidence that the alleged incident was accurately reported and determining whether the decision or action seemed to be justifiable and/or ethical. Reported incidents of genetic discrimination were verified in life insurance access, underwriting and coercion (9), applications for worker's compensation (1) and early release from prison (1) and in two cases of fear of discrimination impacting on access to genetic testing. Relevant conditions were inherited cancer susceptibility (8), Huntington disease (3), hereditary hemochromatosis (1), and polycystic kidney disease (1). In two cases, the reversal of an adverse underwriting decision to standard rate after intervention with insurers by genetics health professionals was verified. The mismatch between consumer and third party accounts in three life insurance incidents involved miscommunication or lack of information provision by financial advisers. These first cases of verified genetic discrimination make it essential for policies and guidelines to be developed and implemented to ensure appropriate use of genetic test results in insurance underwriting, to promote education and training in the financial industry, and to provide support for consumers and health professionals undertaking challenges of adverse decisions.

  15. Virtualization Technology for System of Systems Test and Evaluation

    Science.gov (United States)

    2012-06-01

    Peterson , Tillman, & Hatfield (1972) outlined the capabilities of virtualization in the early days of VM with some guiding principles. The following...Sheikh, based on the work of Balci (1994, 1995), and Balci et al. ( 1996 ), seeks to organize types of tests and to align requirements to the appropriate...Verification, validation, and testing in software engineering (pp. 155–184). Hershey , PA: Idea Group. Adair, R. J., Bayles, R. U., Comeau, L. W

  16. Testing and Performance Verification of a High Bypass Ratio Turbofan Rotor in an Internal Flow Component Test Facility

    Science.gov (United States)

    VanZante, Dale E.; Podboy, Gary G.; Miller, Christopher J.; Thorp, Scott A.

    2009-01-01

    A 1/5 scale model rotor representative of a current technology, high bypass ratio, turbofan engine was installed and tested in the W8 single-stage, high-speed, compressor test facility at NASA Glenn Research Center (GRC). The same fan rotor was tested previously in the GRC 9x15 Low Speed Wind Tunnel as a fan module consisting of the rotor and outlet guide vanes mounted in a flight-like nacelle. The W8 test verified that the aerodynamic performance and detailed flow field of the rotor as installed in W8 were representative of the wind tunnel fan module installation. Modifications to W8 were necessary to ensure that this internal flow facility would have a flow field at the test package that is representative of flow conditions in the wind tunnel installation. Inlet flow conditioning was designed and installed in W8 to lower the fan face turbulence intensity to less than 1.0 percent in order to better match the wind tunnel operating environment. Also, inlet bleed was added to thin the casing boundary layer to be more representative of a flight nacelle boundary layer. On the 100 percent speed operating line the fan pressure rise and mass flow rate agreed with the wind tunnel data to within 1 percent. Detailed hot film surveys of the inlet flow, inlet boundary layer and fan exit flow were compared to results from the wind tunnel. The effect of inlet casing boundary layer thickness on fan performance was quantified. Challenges and lessons learned from testing this high flow, low static pressure rise fan in an internal flow facility are discussed.

  17. Transparency in practice: Evidence from 'verification analyses' issued by the Polish Agency for Health Technology Assessment in 2012-2015.

    Science.gov (United States)

    Ozierański, Piotr; Löblová, Olga; Nicholls, Natalia; Csanádi, Marcell; Kaló, Zoltán; McKee, Martin; King, Lawrence

    2018-01-08

    Transparency is recognised to be a key underpinning of the work of health technology assessment (HTA) agencies, yet it has only recently become a subject of systematic inquiry. We contribute to this research field by considering the Polish Agency for Health Technology Assessment (AHTAPol). We situate the AHTAPol in a broader context by comparing it with the National Institute for Health and Care Excellence (NICE) in England. To this end, we analyse all 332 assessment reports, called verification analyses, that the AHTAPol issued from 2012 to 2015, and a stratified sample of 22 Evidence Review Group reports published by NICE in the same period. Overall, by increasingly presenting its key conclusions in assessment reports, the AHTAPol has reached the transparency standards set out by NICE in transparency of HTA outputs. The AHTAPol is more transparent than NICE in certain aspects of the HTA process, such as providing rationales for redacting assessment reports and providing summaries of expert opinions. Nevertheless, it is less transparent in other areas of the HTA process, such as including information on expert conflicts of interest. Our findings have important implications for understanding HTA in Poland and more broadly. We use them to formulate recommendations for policymakers.

  18. Reliability tests for reactor internals rejuvenation technology

    International Nuclear Information System (INIS)

    Fujimaki, Katsumi; Hitoki, Yoichi; Otsubo, Toru; Uchiyama, Junichi

    1998-01-01

    Structural damage due to aging degradation of LWR reactor internals has been reported in several nuclear plants. NUPEC has started a project to test the reliability of the technology for rejuvenating reactor internals which has been funded by the Ministry of International Trade and Industry (MITI) of Japan since 1995. The project follows the policy of a report that the MITI has formally issued in April 1996 summarizing the countermeasures to be considered for aging nuclear plants and equipment. This paper gives an outline of the test plans and results which are directed at preventive maintenance before damage and repair after damage for reactor internals aging degradation. The test results for the replacement methods of ICM housing and BWR core shroud have shown that the methods were reliable and the structural integrity was appropriate based on the evaluation. (author)

  19. In-Field Performance Testing of the Fork Detector for Quantitative Spent Fuel Verification

    International Nuclear Information System (INIS)

    Gauld, Ian C.; Hu, Jianwei; De Baere, P.; Tobin, Stephen

    2015-01-01

    Expanding spent fuel dry storage activities worldwide are increasing demands on safeguards authorities that perform inspections. The European Atomic Energy Community (EURATOM) and the International Atomic Energy Agency (IAEA) require measurements to verify declarations when spent fuel is transferred to difficult-to-access locations, such as dry storage casks and the repositories planned in Finland and Sweden. EURATOM makes routine use of the Fork detector to obtain gross gamma and total neutron measurements during spent fuel inspections. Data analysis is performed by modules in the integrated Review and Analysis Program (iRAP) software, developed jointly by EURATOM and the IAEA. Under the framework of the US Department of Energy-EURATOM cooperation agreement, a module for automated Fork detector data analysis has been developed by Oak Ridge National Laboratory (ORNL) using the ORIGEN code from the SCALE code system and implemented in iRAP. EURATOM and ORNL recently performed measurements on 30 spent fuel assemblies at the Swedish Central Interim Storage Facility for Spent Nuclear Fuel (Clab), operated by the Swedish Nuclear Fuel and Waste Management Company (SKB). The measured assemblies represent a broad range of fuel characteristics. Neutron count rates for 15 measured pressurized water reactor assemblies are predicted with an average relative standard deviation of 4.6%, and gamma signals are predicted on average within 2.6% of the measurement. The 15 measured boiling water reactor assemblies exhibit slightly larger deviations of 5.2% for the gamma signals and 5.7% for the neutron count rates, compared to measurements. These findings suggest that with improved analysis of the measurement data, existing instruments can provide increased verification of operator declarations of the spent fuel and thereby also provide greater ability to confirm integrity of an assembly. These results support the application of the Fork detector as a fully quantitative spent fuel

  20. In-Field Performance Testing of the Fork Detector for Quantitative Spent Fuel Verification

    Energy Technology Data Exchange (ETDEWEB)

    Gauld, Ian C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hu, Jianwei [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); De Baere, P. [European Commission (Luxembourg). DG Energy, Directorate Nuclear Safeguards; Vaccaro, S. [European Commission (Luxembourg). DG Energy, Directorate Nuclear Safeguards; Schwalbach, P. [European Commission (Luxembourg). DG Energy, Directorate Nuclear Safeguards; Liljenfeldt, Henrik [Swedish Nuclear Fuel and Waste Management Company (Sweden); Tobin, Stephen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-01-01

    Expanding spent fuel dry storage activities worldwide are increasing demands on safeguards authorities that perform inspections. The European Atomic Energy Community (EURATOM) and the International Atomic Energy Agency (IAEA) require measurements to verify declarations when spent fuel is transferred to difficult-to-access locations, such as dry storage casks and the repositories planned in Finland and Sweden. EURATOM makes routine use of the Fork detector to obtain gross gamma and total neutron measurements during spent fuel inspections. Data analysis is performed by modules in the integrated Review and Analysis Program (iRAP) software, developed jointly by EURATOM and the IAEA. Under the framework of the US Department of Energy–EURATOM cooperation agreement, a module for automated Fork detector data analysis has been developed by Oak Ridge National Laboratory (ORNL) using the ORIGEN code from the SCALE code system and implemented in iRAP. EURATOM and ORNL recently performed measurements on 30 spent fuel assemblies at the Swedish Central Interim Storage Facility for Spent Nuclear Fuel (Clab), operated by the Swedish Nuclear Fuel and Waste Management Company (SKB). The measured assemblies represent a broad range of fuel characteristics. Neutron count rates for 15 measured pressurized water reactor assemblies are predicted with an average relative standard deviation of 4.6%, and gamma signals are predicted on average within 2.6% of the measurement. The 15 measured boiling water reactor assemblies exhibit slightly larger deviations of 5.2% for the gamma signals and 5.7% for the neutron count rates, compared to measurements. These findings suggest that with improved analysis of the measurement data, existing instruments can provide increased verification of operator declarations of the spent fuel and thereby also provide greater ability to confirm integrity of an assembly. These results support the application of the Fork detector as a fully quantitative spent fuel

  1. Verification of the HDR-test V44 using the computer program RALOC-MOD1/83

    International Nuclear Information System (INIS)

    Jahn, H.; Pham, T. v.; Weber, G.; Pham, B.T.

    1985-01-01

    RALOC-MOD1/83 was extended by a drainage and sump level modul and several component models to serve as a containment systems code for various LWR types. One such application is to simulate the blowdown in a full pressure containment which is important for the short and long term hydrogen distribution. The post test calculation of the containment standard problem experiment HDR-V44 shows a good agreement, to the test data. The code may be used for short and long term predictions, but it was learned that double containments need the representation of the gap between the inner and outer shell into several zones to achieve a good long-term temperature prediction. The present work completes the development, verification and documentation of RALOC-MOD1. (orig.) [de

  2. 40 CFR 86.1847-01 - Manufacturer in-use verification and in-use confirmatory testing; submittal of information and...

    Science.gov (United States)

    2010-07-01

    ... laboratory equipment calibrations and verifications as prescribed by subpart B of this part or by good... in-use confirmatory testing; submittal of information and maintenance of records. 86.1847-01 Section... confirmatory testing; submittal of information and maintenance of records. (a) The manufacturer who conducts or...

  3. Characteristic test technology for PWR fuel and its components

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Ho; Lee, Chan Bock; Bang, Je Gun; Jung, Yeon Ho; Jeong, Yong Hwan; Park, Sang Yoon; Kim, Kyeng Ho; Nam, Cheol; Baek, Jong Hyuk; Lee, Myung Ho; Choi, Byoung Kwon; Song, Kun Woo; Kang, Ki Won; Kim, Keon Sik; Kim, Jong Hun; Kim, Young Min; Yang, Jae Ho; Song, Kee Nam; Kim, Hyung Kyu; Kang, Heung Seok; Yoon, Kyung Ho; Chun, Tae Hyun; In, Wang Kee; Oh, Dong Seok [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2000-01-01

    Characteristic tests of fuel assembly and its components being developed in the Advanced LWR Fuel Development Project supported by the mid-long term nuclear R and D program are described in this report. Performance verification of fuel and its components by the characteristic tests are essential to their development. Fuel components being developed in the Advanced LWR Fuel Development Project are zirconium alloy cladding, UO{sub 2} and burnable absorber pellets, spacer grid and top and bottom end pieces. Detailed test plans for those fuel components are described in this report, and test procedures of cladding and pellet are also described in the Appendix. Examples of the described tests are in- and out-of- pile corrosion and mechanical tests such as creep and burst tests for the cladding, in-pile capsule and ramp tests for the pellet, mechanical tests such as strength and vibration, and thermal-hydraulic tests such as pressure drop and critical heat flux for the spacer grid and top and bottom end pieces. It is expected that this report could be used as the standard reference for the performance verification tests in the development of LWR fuel and its components. 11 refs., 9 figs., 2 tabs. (Author)

  4. Seismic verification of underground explosions

    International Nuclear Information System (INIS)

    Glenn, L.A.

    1985-06-01

    The first nuclear test agreement, the test moratorium, was made in 1958 and lasted until the Soviet Union unilaterally resumed testing in the atmosphere in 1961. It was followed by the Limited Test Ban Treaty of 1963, which prohibited nuclear tests in the atmosphere, in outer space, and underwater. In 1974 the Threshold Test Ban Treaty (TTBT) was signed, limiting underground tests after March 1976 to a maximum yield of 250 kt. The TTBT was followed by a treaty limiting peaceful nuclear explosions and both the United States and the Soviet Union claim to be abiding by the 150-kt yield limit. A comprehensive test ban treaty (CTBT), prohibiting all testing of nuclear weapons, has also been discussed. However, a verifiable CTBT is a contradiction in terms. No monitoring technology can offer absolute assurance that very-low-yield illicit explosions have not occurred. The verification process, evasion opportunities, and cavity decoupling are discussed in this paper

  5. Satellite Power Systems (SPS) concept definition study. Volume 6: SPS technology requirements and verification

    Science.gov (United States)

    Hanley, G.

    1978-01-01

    Volume 6 of the SPS Concept Definition Study is presented and also incorporates results of NASA/MSFC in-house effort. This volume includes a supporting research and technology summary. Other volumes of the final report that provide additional detail are as follows: (1) Executive Summary; (2) SPS System Requirements; (3) SPS Concept Evolution; (4) SPS Point Design Definition; (5) Transportation and Operations Analysis; and Volume 7, SPS Program Plan and Economic Analysis.

  6. System Verification Through Reliability, Availability, Maintainability (RAM) Analysis & Technology Readiness Levels (TRLs)

    Energy Technology Data Exchange (ETDEWEB)

    Emmanuel Ohene Opare, Jr.; Charles V. Park

    2011-06-01

    The Next Generation Nuclear Plant (NGNP) Project, managed by the Idaho National Laboratory (INL), is authored by the Energy Policy Act of 2005, to research, develop, design, construct, and operate a prototype fourth generation nuclear reactor to meet the needs of the 21st Century. A section in this document proposes that the NGNP will provide heat for process heat applications. As with all large projects developing and deploying new technologies, the NGNP is expected to meet high performance and availability targets relative to current state of the art systems and technology. One requirement for the NGNP is to provide heat for the generation of hydrogen for large scale productions and this process heat application is required to be at least 90% or more available relative to other technologies currently on the market. To reach this goal, a RAM Roadmap was developed highlighting the actions to be taken to ensure that various milestones in system development and maturation concurrently meet required availability requirements. Integral to the RAM Roadmap was the use of a RAM analytical/simulation tool which was used to estimate the availability of the system when deployed based on current design configuration and the maturation level of the system.

  7. Remote communications technology redefines integrity verification and monitoring of low pressure isolation

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2010-01-15

    In 2007, a ship collided with the southeast face of a satellite platform jacket in the North Sea, damaging the 12-inch export riser. Emergency shutdown valves immediately shut-in production from the platform, leaving the pressure in the pipeline at approximately 4 barg. The riser had to be repaired before production could resume. TDW Offshore Services (TDW) was hired to develop a low pressure solution to isolate the damaged section of the pipeline riser from the export pipeline gas inventory. TDW used its range of specialist pipeline pigging, pig tracking and remote communications technology to solve the problem. The solution consisted of a custom-designed TDW pig trap and pigging spread; a high friction pig train furnished with the SmartTrack remote tracking and pressure-monitoring system; a SmartTrack subsea remote tracking and pressure-monitoring system; a SmartTrack topside tracking and monitoring system with radio link to the dive support vessel; and a pipeline isolation ball valve. TDW was able to monitor the downstream pressure of each isolation pig continuously throughout the operation using its innovative technology that sends isolation integrity data by radio link to a dive support vessel through pipe wall communications. The use of remote tracking and pressure monitoring technology enabled TDW to make repairs to the damaged riser while maintaining a continuous flow throughout the duration of the operation. 4 figs.

  8. Off reactor testings. Technological engineering applicative research

    International Nuclear Information System (INIS)

    Doca, Cezar

    2001-01-01

    By the end of year 2000 over 400 nuclear electro-power units were operating world wide, summing up a 350,000 MW total capacity, with a total production of 2,300 TWh, representing 16% of the world's electricity production. Other 36 units, totalizing 28,000 MW, were in construction, while a manifest orientation towards nuclear power development was observed in principal Asian countries like China, India, Japan and Korea. In the same world's trend one find also Romania, the Cernavoda NPP Unit 1 generating electrical energy into the national system beginning with 2 December 1996. Recently, the commercial contract was completed for finishing the Cernavoda NPP Unit 2 and launching it into operation by the end of year 2004. An important role in developing the activity of research and technological engineering, as technical support for manufacturing the CANDU type nuclear fuel and supplying with equipment the Cernavoda units, was played by the Division 7 TAR of the INR Pitesti. Qualification testings were conducted for: - off-reactor CANDU type nuclear fuel; - FARE tools, pressure regulators, explosion proof panels; channel shutting, as well as functional testing for spare pushing facility as a first step in the frame of the qualification tests for the charging/discharging machine (MID) 4 and 5 endings. Testing facilities are described, as well as high pressure hot/cool loops, measuring chains, all of them fulfilling the requirements of quality assurance. The nuclear fuel off-reactor tests were carried out to determine: strength; endurance; impact, pressure fall and wear resistance. For Cernavoda NPP equipment testings were carried out for: the explosion proof panels, pressure regulators, behaviour to vibration and wear of the steam generation tubings, effects of vibration upon different electronic component, channel shutting (for Cernavoda Unit 2), MID operating at 300 and 500 cycles. A number of R and D programs were conducted in the frame of division 7 TAR of INR

  9. Accumulation of operational history through emulation test to meet proven technology requirement for newly developed I and C technology

    International Nuclear Information System (INIS)

    Yeong Cheol, Shin; Sung Kon, Kang; Han Seong, Son

    2006-01-01

    As new advanced digital I and C technology with potential benefits of higher functionality and better cost effectiveness is available in the market, NPP (Nuclear Power Plant) operators are inclined to use the new technology for the construction of new plant and the upgrade of existing plants. However, this new technology poses risks to the NPP operators at the same time. These risks are mainly due to the poor reliability of newly developed technology. KHNP's past experiences with the new equipment shows many cases of reliability problems. And their consequences include unintended plant trips, lowered acceptance of the new digital technology by the plant I and C maintenance crew, and increased licensing burden in answering for questions from the nuclear regulatory body. Considering the fact that the risk of these failures in the nuclear plant operation is far greater than those in other industry, nuclear power plant operators want proven technology for I and C systems. This paper presents an approach for the emulation of operational history through which a newly developed technology becomes a proven technology. One of the essential elements of this approach is the feedback scheme of running the new equipment in emulated environment, gathering equipment failure, and correcting the design(and test bed). The emulation of environment includes normal and abnormal events of the new equipment such as reconfiguration of control system due to power failure, plant operation including full spectrum of credible scenarios in an NPP. Emulation of I and C equipment execution mode includes normal operation, initialization and termination, abnormal operation, hardware maintenance and maintenance of algorithm/software. Plant specific simulator is used to create complete profile of plant operational conditions that I and C equipment is to experience in the real plant. Virtual operating crew technology is developed to run the simulator scenarios without involvement of actual operators

  10. Integration of multidisciplinary technologies for real time target visualization and verification for radiotherapy

    Directory of Open Access Journals (Sweden)

    Chang WC

    2014-06-01

    Full Text Available Wen-Chung Chang,1,* Chin-Sheng Chen,2,* Hung-Chi Tai,3 Chia-Yuan Liu,4,5 Yu-Jen Chen3 1Department of Electrical Engineering, National Taipei University of Technology, Taipei, Taiwan; 2Graduate Institute of Automation Technology, National Taipei University of Technology, Taipei, Taiwan; 3Department of Radiation Oncology, Mackay Memorial Hospital, Taipei, Taiwan; 4Department of Internal Medicine, Mackay Memorial Hospital, Taipei, Taiwan; 5Department of Medicine, Mackay Medical College, New Taipei City, Taiwan  *These authors contributed equally to this work Abstract: The current practice of radiotherapy examines target coverage solely from digitally reconstructed beam's eye view (BEV in a way that is indirectly accessible and that is not in real time. We aimed to visualize treatment targets in real time from each BEV. The image data of phantom or patients from ultrasound (US and computed tomography (CT scans were captured to perform image registration. We integrated US, CT, US/CT image registration, robotic manipulation of US, a radiation treatment planning system, and a linear accelerator to constitute an innovative target visualization system. The performance of this algorithm segmented the target organ in CT images, transformed and reconstructed US images to match each orientation, and generated image registration in real time mode with acceptable accuracy. This image transformation allowed physicians to visualize the CT image-reconstructed target via a US probe outside the BEV that was non-coplanar to the beam's plane. It allowed the physicians to remotely control the US probe that was equipped on a robotic arm to dynamically trace and real time monitor the coverage of the target within the BEV during a simulated beam-on situation. This target visualization system may provide a direct remotely accessible and real time way to visualize, verify, and ensure tumor targeting during radiotherapy. Keywords: ultrasound, computerized tomography

  11. CTBT verification-related technologies for peaceful purposes: Implementation of CTBT in Iran

    International Nuclear Information System (INIS)

    Ghafory-Ashtiany, M.; Hosseinie, Mohammad-Taghi

    1999-01-01

    Based on its strong policy on disarmament and non proliferation, Islamic Republic of Iran considers CTBT as one of the measures towards the safe world and free from nuclear weapons. It is believed that full implementation of this treaty increases international security as well as national security of every state signatory. It is also considered that it has many scientific and technological benefits for sustainable development of the countries. This paper deals with international monitoring system in Iran, including primary and auxiliary seismic stations, infrasound and radionuclides monitoring systems

  12. Engineering Trade-off Considerations Regarding Design-for-Security, Design-for-Verification, and Design-for-Test

    Science.gov (United States)

    Berg, Melanie; Label, Kenneth

    2018-01-01

    The United States government has identified that application specific integrated circuit (ASIC) and field programmable gate array (FPGA) hardware are at risk from a variety of adversary attacks. This finding affects system security and trust. Consequently, processes are being developed for system mitigation and countermeasure application. The scope of this tutorial pertains to potential vulnerabilities and countermeasures within the ASIC/FPGA design cycle. The presentation demonstrates how design practices can affect the risk for the adversary to: change circuitry, steal intellectual property, and listen to data operations. An important portion of the design cycle is assuring the design is working as specified or as expected. This is accomplished by exhaustive testing of the target design. Alternatively, it has been shown that well established schemes for test coverage enhancement (design-for-verification (DFV) and design-for-test (DFT)) can create conduits for adversary accessibility. As a result, it is essential to perform a trade between robust test coverage versus reliable design implementation. The goal of this tutorial is to explain the evolution of design practices; review adversary accessibility points due to DFV and DFT circuitry insertion (back door circuitry); and to describe common engineering trade-off considerations for test versus adversary threats.

  13. Pre-Analysis for Safety-Related Verification Test Using TASS/SMR Code

    Energy Technology Data Exchange (ETDEWEB)

    Ra, I. S.; Kim, H. J.; Jeon, G. H. [ACTS Ltd., Daejeon (Korea, Republic of)

    2010-01-15

    General trends of TASS/SMR simulation were similar to those in both ORNF test and BENNETT test conducted to verify core heat transfer model in TASS/SMR. In high mass flux, however, a CHF location in the analytical result of TASS/SMR was greatly deviated from BENNETT test result. TASS/SMR gave better results in heterogeneous option that in homogeneous option in both KIT test, which was a steady state test with an inlet flow, and GE-LEVEL Swell test, which a transient test without an inlet flow. TASS/SMR simulation for SMD Long and Short test gave a good agreement with the test results in showing a reasonable predictability of critical flow model. But, in the case of Marviken test, the analytical result was not similar to the test result after the timing of vapor generation

  14. Environmental assessment report: Nuclear Test Technology Complex

    International Nuclear Information System (INIS)

    Tonnessen, K.; Tewes, H.A.

    1982-08-01

    The US Department of Energy (USDOE) is planning to construct and operate a structure, designated the Nuclear Test Technology Complex (NTTC), on a site located west of and adjacent to the Lawrence Livermore National Laboratory. The NTTC is designed to house 350 nuclear test program personnel, and will accommodate the needs of the entire staff of the continuing Nuclear Test Program (NTP). The project has three phases: land acquisition, facility construction and facility operation. The purpose of this environmental assessment report is to describe the activities associated with the three phases of the NTTC project and to evaluate potential environmental disruptions. The project site is located in a rural area of southeastern Alameda County, California, where the primary land use is agriculture; however, the County has zoned the area for industrial development. The environmental impacts of the project include surface disturbance, high noise levels, possible increases in site erosion, and decreased air quality. These impacts will occur primarily during the construction phase of the NTTC project and can be mitigated in part by measures proposed in this report

  15. Nuclear cooperation targets global challenges. States back main pillars of the IAEA's work to strengthen nuclear safety, verification and technology transfer

    International Nuclear Information System (INIS)

    2000-01-01

    States meeting at the 44th IAEA General Conference in Vienna have set a challenging agenda for international nuclear cooperation into the 21st century that targets issues of global safety, security, and sustainable development. They adopted resolutions endorsing the Agency's programmes for strengthening activities under its three main pillars of work - nuclear verification, safety, and technology - that are closely linked to major challenges before the world. The document presents the main actions taken during the conference

  16. Reliability Verification of DBE Environment Simulation Test Facility by using Statistics Method

    International Nuclear Information System (INIS)

    Jang, Kyung Nam; Kim, Jong Soeg; Jeong, Sun Chul; Kyung Heum

    2011-01-01

    In the nuclear power plant, all the safety-related equipment including cables under the harsh environment should perform the equipment qualification (EQ) according to the IEEE std 323. There are three types of qualification methods including type testing, operating experience and analysis. In order to environmentally qualify the safety-related equipment using type testing method, not analysis or operation experience method, the representative sample of equipment, including interfaces, should be subjected to a series of tests. Among these tests, Design Basis Events (DBE) environment simulating test is the most important test. DBE simulation test is performed in DBE simulation test chamber according to the postulated DBE conditions including specified high-energy line break (HELB), loss of coolant accident (LOCA), main steam line break (MSLB) and etc, after thermal and radiation aging. Because most DBE conditions have 100% humidity condition, in order to trace temperature and pressure of DBE condition, high temperature steam should be used. During DBE simulation test, if high temperature steam under high pressure inject to the DBE test chamber, the temperature and pressure in test chamber rapidly increase over the target temperature. Therefore, the temperature and pressure in test chamber continue fluctuating during the DBE simulation test to meet target temperature and pressure. We should ensure fairness and accuracy of test result by confirming the performance of DBE environment simulation test facility. In this paper, in order to verify reliability of DBE environment simulation test facility, statistics method is used

  17. Monitoring and verification R and D

    International Nuclear Information System (INIS)

    Pilat, Joseph F.; Budlong-Sylvester, Kory W.; Fearey, Bryan L.

    2011-01-01

    The 2010 Nuclear Posture Review (NPR) report outlined the Administration's approach to promoting the agenda put forward by President Obama in Prague on April 5, 2009. The NPR calls for a national monitoring and verification R and D program to meet future challenges arising from the Administration's nonproliferation, arms control and disarmament agenda. Verification of a follow-on to New START could have to address warheads and possibly components along with delivery capabilities. Deeper cuts and disarmament would need to address all of these elements along with nuclear weapon testing, nuclear material and weapon production facilities, virtual capabilities from old weapon and existing energy programs and undeclared capabilities. We only know how to address some elements of these challenges today, and the requirements may be more rigorous in the context of deeper cuts as well as disarmament. Moreover, there is a critical need for multiple options to sensitive problems and to address other challenges. There will be other verification challenges in a world of deeper cuts and disarmament, some of which we are already facing. At some point, if the reductions process is progressing, uncertainties about past nuclear materials and weapons production will have to be addressed. IAEA safeguards will need to continue to evolve to meet current and future challenges, and to take advantage of new technologies and approaches. Transparency/verification of nuclear and dual-use exports will also have to be addressed, and there will be a need to make nonproliferation measures more watertight and transparent. In this context, and recognizing we will face all of these challenges even if disarmament is not achieved, this paper will explore possible agreements and arrangements; verification challenges; gaps in monitoring and verification technologies and approaches; and the R and D required to address these gaps and other monitoring and verification challenges.

  18. Non-radioactive verification test of ZRF25 radioactive combustible solid waste incinerator

    International Nuclear Information System (INIS)

    Wang Peiyi; Li Xiaohai; Yang Liguo

    2013-01-01

    This paper mainly introduces the construction and test run of ZRF25 radioactive combustible solid waste incinerator, by a series of simulating waste tests, such as 24 h test, 72 h test, 168 h test, making a conclusion that the incinerator runs reliably. In addition, all of the indexes (such as treatment capacity, volume reduction coefficient, clinker ignition loss of incineration ash) meet the requirements of contract and pollution discharging standards. (authors)

  19. Verification of best available technology for the 300 Area Treated Effluent Disposal Facility (310 Facility)

    International Nuclear Information System (INIS)

    Wagner, R.N.

    1994-01-01

    This compilation of Project L-045H reference materials documents that the 300 Area Treated Effluent Disposal Facility (TEDF, also designated the 310 Facility) was designed, built, and will be operated in accordance with the best available technology (BAT) identified in the Engineering Summary Report. The facility is intended for treatment of 300 Area process sewer wastewater. The following unit operations for 300 Area process sewer water treatment are specified as: influent receipt; iron co-precipitation and sludge handling for removal of heavy metals and initial suspended solids; ion exchanged for removal of mercury and other heavy metals; ultraviolet (UV)/peroxide treatment for destruction of organic compounds, cyanide, coliforms, sulfide, and nitrite; and effluent discharge to the Columbia River with pH monitoring/control capability

  20. Development of the SEAtrace{trademark} barrier verification and validation technology. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Dunn, S.D.; Lowry, W.; Walsh, R.; Rao, D.V. [Science and Engineering Associates, Santa Fe, NM (United States); Williams, C. [Sandia National Labs., Albuquerque, NM (United States). Underground Storage Technology Dept.

    1998-08-01

    In-situ barrier emplacement techniques and materials for the containment of high-risk contaminants in soils are currently being developed by the Department of Energy (DOE). Because of their relatively high cost, the barriers are intended to be used in cases where the risk is too great to remove the contaminants, the contaminants are too difficult to remove with current technologies, or the potential movement of the contaminants to the water table is so high that immediate action needs to be taken to reduce health risks. Assessing the integrity of the barrier once it is emplaced, and during its anticipated life, is a very difficult but necessary requirement. Science and Engineering Associates, Inc., (SEA) and Sandia National Laboratories (SNL) have developed a quantitative subsurface barrier assessment system using gaseous tracers in support of the Subsurface Contaminants Focus Area barrier technology program. Called SEAtrace{trademark}, this system integrates an autonomous, multi-point soil vapor sampling and analysis system with a global optimization modeling methodology to locate and size barrier breaches in real time. The methodology for the global optimization code was completed and a prototype code written using simplifying assumptions. Preliminary modeling work to validate the code assumptions were performed using the T2VOC numerical code. A multi-point field sampling system was built to take soil gas samples and analyze for tracer gas concentration. The tracer concentration histories were used in the global optimization code to locate and size barrier breaches. SEAtrace{trademark} was consistently able to detect and locate leaks, even under very adverse conditions. The system was able to locate the leak to within 0.75 m of the actual value, and was able to determine the size of the leak to within 0.15 m.

  1. Development of the SEAtrace trademark barrier verification and validation technology. Final report

    International Nuclear Information System (INIS)

    Dunn, S.D.; Lowry, W.; Walsh, R.; Rao, D.V.; Williams, C.

    1998-08-01

    In-situ barrier emplacement techniques and materials for the containment of high-risk contaminants in soils are currently being developed by the Department of Energy (DOE). Because of their relatively high cost, the barriers are intended to be used in cases where the risk is too great to remove the contaminants, the contaminants are too difficult to remove with current technologies, or the potential movement of the contaminants to the water table is so high that immediate action needs to be taken to reduce health risks. Assessing the integrity of the barrier once it is emplaced, and during its anticipated life, is a very difficult but necessary requirement. Science and Engineering Associates, Inc., (SEA) and Sandia National Laboratories (SNL) have developed a quantitative subsurface barrier assessment system using gaseous tracers in support of the Subsurface Contaminants Focus Area barrier technology program. Called SEAtrace trademark, this system integrates an autonomous, multi-point soil vapor sampling and analysis system with a global optimization modeling methodology to locate and size barrier breaches in real time. The methodology for the global optimization code was completed and a prototype code written using simplifying assumptions. Preliminary modeling work to validate the code assumptions were performed using the T2VOC numerical code. A multi-point field sampling system was built to take soil gas samples and analyze for tracer gas concentration. The tracer concentration histories were used in the global optimization code to locate and size barrier breaches. SEAtrace trademark was consistently able to detect and locate leaks, even under very adverse conditions. The system was able to locate the leak to within 0.75 m of the actual value, and was able to determine the size of the leak to within 0.15 m

  2. FY 1983 report on the results of the verification test on the methanol conversion for oil-fired power plant. Part 1. Verification test on the environmental safety; 1983 nendo sekiyu karyoku hatsudensho metanoru tenkan tou jissho shiken seika hokokusho. Kankyo anzensei jissho shiken (Sono 1)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1984-03-01

    As to the verification test on the environmental safety in the use of methanol as power generation use fuel, the following were summed up: review of the verification test and the interim evaluation, state of implementation of the FY 1983 verification test, study/evaluation of the results of the FY 1983 test, survey of research trends, plan of the FY 1984 verification test, record of the committee, etc. Concerning the interim evaluation, high evaluation was obtained as described below: Testing facilities were constructed as planned at first to make the implementation of various tests possible; Tests were smoothly conducted, and among the acute test using monkey, test on mock flue gas using monkey/rat, test on mutagenicity and test on the effect on aquatic animals, tests using oryzias latipes and abalone on the fatal concentration, avoidance behavior and chronic effect were finished by the end of FY 1983 almost as planned; The long-term inhalation test using monkey and rat/mouse has been smoothly in progress. In the survey of research trends, the paper introduced the outlined literature on the methanol metabolism of monkey, changes in the methanol concentration in blood/urine in the case of drinking methanol by mistake. (NEDO)

  3. State-of-the-art report for the testing and formal verification methods for FBD program

    International Nuclear Information System (INIS)

    Jee, Eun Kyoung; Lee, Jang Soo; Lee, Young Jun; Yoo, Jun Beom

    2011-10-01

    The importance of PLC testing has increased in the nuclear I and C domain. While regulation authorities require both functional and structural testing for safety system software, FBD testing relies only on functional testing and there has been little research on structural testing techniques for FBD programs. We aim to analyze current techniques related to FBD testing and develop a structural testing technique appropriate to FBD programs. We developed structural test coverage criteria applicable to FBD programs, focusing on data paths from input edges to output edges of FBD programs. A data path condition (DPC), under which input data can flow into the output edge, is defined for each data path. We defined basic coverage, input condition coverage and complex condition coverage criteria based on the formal definition of DPC. We also developed a measurement procedure for FBD testing adequacy and a supporting tool prototype

  4. Arms Control and nonproliferation technologies: Technology options and associated measures for monitoring a Comprehensive Test Ban, Second quarter

    Energy Technology Data Exchange (ETDEWEB)

    Casey, Leslie A.

    1994-01-01

    This newsletter contains reprinted papers discussing technology options and associated measures for monitoring a Comprehensive Test Ban Treaty (CTBT). These papers were presented to the Conference on Disarmament (CD) in May and June 1994. An interagency Verification Monitoring Task Force developed the papers. The task force included participants from the Arms Control and Disarmament Agency, the Department of Defense, the Department of Energy, the Intelligence Community, the Department of Interior, and the Department of State. The purpose of this edition of Arms Control and Nonproliferation Technologies is to share these papers with the broad base of stakeholders in a CTBT and to facilitate future technology discussions. The papers in the first group discuss possible technology options for monitoring a CTBT in all environments (underground, underwater, atmosphere, and space). These technologies, along with on-site inspections, would facilitate CTBT monitoring by treaty participants. The papers in the second group present possible associated measures, e.g., information exchanges and transparency measures, that would build confidence among states participating in a CTBT.

  5. Verification of new technologies introduced into the privately-owned port of Higashidori Nuclear Power Station

    International Nuclear Information System (INIS)

    Murano, Sei-ichiro; Ozaki, Tsutomu; Date, Masanao

    2005-01-01

    The privately-owned port of Higashidori Nuclear Power Station introduced the rubble-slopping breakwater as the seawall and the concrete-caisson breakwater (new caisson breakwater) as the outlet seawall. The distribution of wave pressure on the new caisson breakwater was measured by the wave pressure meteor set on it and compared with the results of the hydraulic model tests. The precast concrete armour unit used Acropod. The conditions of new caisson breakwater, measurement of wave pressure, and the optimum conditions of seawall are stated. The new caisson breakwater showed the high dispersive effect of the impact wave force on the surf zone. The construction cost was decreased by reduction of sectional area and the wave dissipating concrete block. There are no problems about the stability of breakwater confirmed by the hydraulic model test. (S.Y.)

  6. Testing of the dual slab verification detector for attended measurements of the BN-350 dry storage casks

    Energy Technology Data Exchange (ETDEWEB)

    Santi, Peter A [Los Alamos National Laboratory; Browne, Michael C [Los Alamos National Laboratory; Williams, Richard B [Los Alamos National Laboratory; Parker, Robert F [Los Alamos National Laboratory

    2009-01-01

    The Dual Slab Verification Detector (DSVD) has been developed and built by Los Alamos National Laboratory in cooperation with the International Atomic Energy Agency (IAEA) as part of the dry storage safeguards system for the spent fuel from the BN-350 fast reactor. The detector consists of two rows of {sup 3}He tubes embedded in a slab of polyethylene which has been designed to be placed on the outer surface of the dry storage cask. The DSVD will be used to perform measurements of the neutron flux emanating from inside the dry storage cask at several locations around each cask to establish a neutron 'fingerprint' that is sensitive to the contents of the cask. The sensitivity of the fingerprinting technique to the removal of specific amount of nuclear material from the cask is determined by the characteristics of the detector that is used to perform the measurements, the characteristics of the spent fuel being measured, and systematic uncertainties that are associated with the dry storage scenario. MCNPX calculations of the BN-350 dry storage asks and layout have shown that the neutron fingerprint verification technique using measurements from the DSVD would be sensitive to both the amount and location of material that is present within an individual cask. To confirm the performance of the neutron fingerprint technique in verifying the presence of BN-350 spent fuel in dry storage, an initial series of measurements have been performed to test the performance and characteristics of the DSVD. Results of these measurements will be presented and compared with MCNPX results.

  7. The design of verification regimes

    International Nuclear Information System (INIS)

    Gallagher, N.W.

    1991-01-01

    Verification of a nuclear agreement requires more than knowledge of relevant technologies and institutional arrangements. It also demands thorough understanding of the nature of verification and the politics of verification design. Arms control efforts have been stymied in the past because key players agreed to verification in principle, only to disagree radically over verification in practice. In this chapter, it is shown that the success and stability of arms control endeavors can be undermined by verification designs which promote unilateral rather than cooperative approaches to security, and which may reduce, rather than enhance, the security of both sides. Drawing on logical analysis and practical lessons from previous superpower verification experience, this chapter summarizes the logic and politics of verification and suggests implications for South Asia. The discussion begins by determining what properties all forms of verification have in common, regardless of the participants or the substance and form of their agreement. Viewing verification as the political process of making decisions regarding the occurrence of cooperation points to four critical components: (1) determination of principles, (2) information gathering, (3) analysis and (4) projection. It is shown that verification arrangements differ primarily in regards to how effectively and by whom these four stages are carried out

  8. Verification of mechanistic-empirical design models for flexible pavements through accelerated pavement testing : technical summary.

    Science.gov (United States)

    2014-08-01

    Midwest States Accelerated Pavement Testing Pooled-Fund Program, financed by the : highway departments of Kansas, Iowa, and Missouri, has supported an accelerated : pavement testing (APT) project to validate several models incorporated in the NCHRP :...

  9. Verification of mechanistic-empirical design models for flexible pavements through accelerated pavement testing.

    Science.gov (United States)

    2014-08-01

    The Midwest States Accelerated Pavement Testing Pooled Fund Program, financed by the highway : departments of Kansas, Iowa, and Missouri, has supported an accelerated pavement testing (APT) project to : validate several models incorporated in the NCH...

  10. Validation of the Information/Communications Technology Literacy Test

    Science.gov (United States)

    2016-10-01

    Technical Report 1360 Validation of the Information /Communications Technology Literacy Test D. Matthew Trippe Human Resources Research...TITLE AND SUBTITLE Validation of the Information /Communications Technology Literacy Test 5a. CONTRACT OR GRANT NUMBER W91WAS-09-D-0013 5b...validate a measure of cyber aptitude, the Information /Communications Technology Literacy Test (ICTL), in predicting trainee performance in Information

  11. Comprehensive Test Ban Treaty (CTBT) Verification research in support of non-proliferation

    International Nuclear Information System (INIS)

    Linger, D.

    1997-01-01

    The Comprehensive Test Ban Treaty (CTBT) prohibits nuclear weapons testing at any yield. The detection and positive identification of any evasive test presents a challenge to the technical community, however. Low yield testing can be masked by normal background seismic noise or permissible chemical explosions for mining or other purposes. Cavity decoupling can reduce the seismic signal from the nuclear explosion by a factor of 50 or more. The combination of decoupling and high explosive masking represents a particular technical challenge for positive identification. To address this problem, a technical program in cooperation with the Kazakhstan National Nuclear Center has been initiated to conduct a series of tests in the Balapan area of the Semipalatinsk Test Site to provide fundamental data on the depth of burial effects on seismic signals emanating from an explosion. If the depth of burial can be positively determined from the characteristics of the seismic waveform, near-surface mining blasts can be distinguished from deep underground evasive nuclear explosions, thus eliminating the capability to easily mask the nuclear event. This paper will briefly describe the basic concepts of some evasive nuclear testing options and discuss the cooperative test program that is being carried out to improve the capability to positively identify such tests. The paper will also discuss possible additional cooperative tests that might be done in 1998 to further improve the identification capability

  12. Research on Digital Output Verification Technology of Electronic DC Current Transformer

    Science.gov (United States)

    Chen, Yuanjie; Wang, Bin; Hu, Haoliang; Xiong, Qianzhu; Yang, Chunyan

    2017-05-01

    Aiming at the error of calibration system when conducting field calibration by electronic DC current transformer’s digital calibration system, an electronic DC current transformer’s digital calibration system based on protocol conversion is proposed and researched. Data frames outputted from merging unit are collected and converted by the system, the digital synchronization is realized by using the synchronous clock device to trigger the second pulse, and it is verified by the virtual instrument design software. The field calibration is conducted to some converter station digital dc current transformer under the rated current of 500A by using the calibration system. By calibrating and analyzing errors, the error is less than 0.075% when tested current is more than 40% of the rated current. According the standard in literature[1], performance of the calibration system is perfect, measured results perfectly meet the requirements of design, and the calibration system has great practical application value.

  13. Lay out, test verification and in orbit performance of HELIOS a temperature control system

    Science.gov (United States)

    Brungs, W.

    1975-01-01

    HELIOS temperature control system is described. The main design features and the impact of interactions between experiment, spacecraft system, and temperature control system requirements on the design are discussed. The major limitations of the thermal design regarding a closer sun approach are given and related to test experience and performance data obtained in orbit. Finally the validity of the test results achieved with prototype and flight spacecraft is evaluated by comparison between test data, orbit temperature predictions and flight data.

  14. Design verification test of instrumented capsule (02F-11K) for nuclear fuel irradiation in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Goo; Sohn, J. M.; Oh, J. M. [and others

    2004-01-01

    An instrumented capsule is being developed to be able to measure fuel characteristics, such as fuel temperature, internal pressure of fuel rod, fuel elongation, and neutron flux, etc., during the irradiation test of nuclear fuel in HANARO. The instrumented capsule for measuring and monitoring fuel centerline temperature and neutron flux was designed and manufactured. The instrumented capsule includes three test fuel rods installed thermocouple to measure fuel centerline temperature and three SPNDs (Self-Powered Neutron Detector) to monitor the neutron flux. Its stability was verified by out-of-pile performance test, and its safety evaluation was also shown that the safety requirements were satisfied. And then, to verify the design of the instrumented capsule in the test hole, it was successfully irradiated in the test hole of HANARO from March 14, 2003 to June 1, 2003 (53.8 full power days at 24 MWth). During irradiation, the centerline temperature of PWR UO{sub 2} fuel pellets fabricated by KEPCO Nuclear Fuel Company and the neutron flux were continuously measured and monitored. The test fuel rods were irradiated at less than 350 W/cm to 5.13 GWD/MTU with fuel centerline peak temperature below 1,375 .deg. C. The structural stability of the capsule was satisfied by the naked eye in service pool of HANARO. The capsule and test fuel rods were dismantled and test fuel rods were examined at the hot cell of IMEF (Irradiated Material Examination Facility)

  15. Experimental study on performance verification tests for coordinate measuring systems with optical distance sensors

    Science.gov (United States)

    Carmignato, Simone

    2009-01-01

    Optical sensors are increasingly used for dimensional and geometrical metrology. However, the lack of international standards for testing optical coordinate measuring systems is currently limiting the traceability of measurements and the easy comparison of different optical systems. This paper presents an experimental investigation on artefacts and procedures for testing coordinate measuring systems equipped with optical distance sensors. The work is aimed at contributing to the standardization of testing methods. The VDI/VDE 2617-6.2:2005 guideline, which is probably the most complete document available at the state of the art for testing systems with optical distance sensors, is examined with specific experiments. Results from the experiments are discussed, with particular reference to the tests used for determining the following characteristics: error of indication for size measurement, probing error and structural resolution. Particular attention is given to the use of artefacts alternative to gauge blocks for determining the error of indication for size measurement.

  16. Test and verification of a reactor protection system application-specific integrated circuit

    International Nuclear Information System (INIS)

    Battle, R.E.; Turner, G.W.; Vandermolen, R.I.; Vitalbo, C.

    1997-01-01

    Application-specific integrated circuits (ASICs) were utilized in the design of nuclear plant safety systems because they have certain advantages over software-based systems and analog-based systems. An advantage they have over software-based systems is that an ASIC design can be simple enough to not include branch statements and also can be thoroughly tested. A circuit card on which an ASIC is mounted can be configured to replace various versions of older analog equipment with fewer design types required. The approach to design and testing of ASICs for safety system applications is discussed in this paper. Included are discussions of the ASIC architecture, how it is structured to assist testing, and of the functional and enhanced circuit testing

  17. Verification of hybrid analysis concept of soil-foundation interaction by field vibration tests - Analytical phase

    International Nuclear Information System (INIS)

    Katayama, I.; Niwa, A.; Kubo, Y.; Penzien, J.

    1987-01-01

    In connection with the previous paper under the same subject, which describes the results obtained by the field vibration tests of five different models, this paper describes the outline of the hybrid analysis code of soil-structure interaction (HASSI) and the results of numerical simulation of the responses obtained at the model 2C in both cases of the forced vibration test and the natural earthquake excitation

  18. Verification of intraspecimen method using constant stress tension test of sensitized alloy 600

    International Nuclear Information System (INIS)

    Lee, Seung Ki; Choi, Hoi Su; Hwang, Il Soon

    2005-01-01

    Stress corrosion cracking (SCC) occurring at the Nibase alloy 600 used in the nuclear power plant SG tubes and CRDM penetration nozzles had been reported after long-term operation in the harsh environment. Intraspecimen method was developed to predict the SCC initiation time statistically. [1] By dividing a test area into a number of smaller regions (intraspecimens) having homogeneous physical and chemical condition each SCC initiation in each intraspecimen could be counted as an independent outcome to provide enough number of statistical data. Earlier work of intraspecimen method had many problems in test method and didn't agree with Weibull statistics which is the theoretical base of intraspecimen method. The test method is improved in this intraspecimen test. To find out the root causes of the problems in earlier work and improve the accuracy of intraspecimen method, two kinds of materials are introduced, which are different in grain size but same in chemical composition. Ni-base alloy 600, heat no. J313 and J323 are used as test materials. Specimens of sensitized Alloy 600 are tested under the condition of constant tensile stress and well defined chemical environment therefore we can easily observe typical intergranular stress corrosion cracking (IGSCC). Material with finer grain (J323) showed the areadependence in agreement with theoretical prediction. But material with coarser grain (J313) did not show any significant area-dependence. While SCC initiates earlier at grain boundaries that are oriented close to normal to the stress axis, crack initiation time showed no correlation with grain boundary misorientation estimated by Electron Back Scattered Diffraction (EBSD). From the SCC initiation tests with two test materials, it is concluded that the number of grains in an intraspecimen, degree of sensitization and uniform stress distribution are important parameters to meet Weibull statistics

  19. Metrology test object for dimensional verification in additive manufacturing of metals for biomedical applications.

    Science.gov (United States)

    Teeter, Matthew G; Kopacz, Alexander J; Nikolov, Hristo N; Holdsworth, David W

    2015-01-01

    Additive manufacturing continues to increase in popularity and is being used in applications such as biomaterial ingrowth that requires sub-millimeter dimensional accuracy. The purpose of this study was to design a metrology test object for determining the capabilities of additive manufacturing systems to produce common objects, with a focus on those relevant to medical applications. The test object was designed with a variety of features of varying dimensions, including holes, cylinders, rectangles, gaps, and lattices. The object was built using selective laser melting, and the produced dimensions were compared to the target dimensions. Location of the test objects on the build plate did not affect dimensions. Features with dimensions less than 0.300 mm did not build or were overbuilt to a minimum of 0.300 mm. The mean difference between target and measured dimensions was less than 0.100 mm in all cases. The test object is applicable to multiple systems and materials, tests the effect of location on the build, uses a minimum of material, and can be measured with a variety of efficient metrology tools (including measuring microscopes and micro-CT). Investigators can use this test object to determine the limits of systems and adjust build parameters to achieve maximum accuracy. © IMechE 2014.

  20. Science and Technology Test Mining: Disruptive Technology Roadmaps

    National Research Council Canada - National Science Library

    Kostoff, Ronald

    2003-01-01

    Disruptive technologies create growth in the industries they penetrate or create entirely new industries through the introduction of products and services that are dramatically cheaper, better, and more convenient...

  1. bcROCsurface: an R package for correcting verification bias in estimation of the ROC surface and its volume for continuous diagnostic tests.

    Science.gov (United States)

    To Duc, Khanh

    2017-11-18

    Receiver operating characteristic (ROC) surface analysis is usually employed to assess the accuracy of a medical diagnostic test when there are three ordered disease status (e.g. non-diseased, intermediate, diseased). In practice, verification bias can occur due to missingness of the true disease status and can lead to a distorted conclusion on diagnostic accuracy. In such situations, bias-corrected inference tools are required. This paper introduce an R package, named bcROCsurface, which provides utility functions for verification bias-corrected ROC surface analysis. The shiny web application of the correction for verification bias in estimation of the ROC surface analysis is also developed. bcROCsurface may become an important tool for the statistical evaluation of three-class diagnostic markers in presence of verification bias. The R package, readme and example data are available on CRAN. The web interface enables users less familiar with R to evaluate the accuracy of diagnostic tests, and can be found at http://khanhtoduc.shinyapps.io/bcROCsurface_shiny/ .

  2. Environmental assessment of general-purpose heat source safety verification testing

    International Nuclear Information System (INIS)

    1995-02-01

    This Environmental Assessment (EA) was prepared to identify and evaluate potential environmental, safety, and health impacts associated with the Proposed Action to test General-Purpose Heat Source (GPHS) Radioisotope Thermoelectric Generator (RTG) assemblies at the Sandia National Laboratories (SNL) 10,000-Foot Sled Track Facility, Albuquerque, New Mexico. RTGs are used to provide a reliable source of electrical power on board some spacecraft when solar power is inadequate during long duration space missions. These units are designed to convert heat from the natural decay of radioisotope fuel into electrical power. Impact test data are required to support DOE's mission to provide radioisotope power systems to NASA and other user agencies. The proposed tests will expand the available safety database regarding RTG performance under postulated accident conditions. Direct observations and measurements of GPHS/RTG performance upon impact with hard, unyielding surfaces are required to verify model predictions and to ensure the continual evolution of the RTG designs that perform safely under varied accident environments. The Proposed Action is to conduct impact testing of RTG sections containing GPHS modules with simulated fuel. End-On and Side-On impact test series are planned

  3. Proceedings of the Joint IAEA/CSNI Specialists' Meeting on Fracture Mechanics Verification by Large-Scale Testing

    International Nuclear Information System (INIS)

    1993-10-01

    This report provides the proceedings of a Specialists' Meeting on Fracture Mechanics Verification by Large-Scale Testing that was held in Oak Ridge, Tennessee, on October 23-25, 1992. The meeting was jointly sponsored by the International Atomic Energy Agency (IAEA) and the Nuclear Energy Agency (NEA) of the Organization for Economic Cooperation and Development. In particular, the International Working Group (IWG) on Life Management of Nuclear Power Plants (LMNPP) was the IAEA sponsor, and the Principal Working Group 3 (PWG-3) (Primary System Component Integrity) of the Committee for the Safety of Nuclear Installations (CSNI) was the NEA's sponsor. This meeting was preceded by two prior international activities that were designed to examine the state-of-the-art in fracture analysis capabilities and emphasized applications to the safety evaluation of nuclear power facilities. The first of those two activities was an IAEA Specialists' Meeting on Fracture Mechanics Verification by Large-Scale Testing that was held at the Staatliche Materialprufungsanstalt (MPA) in Stuttgart, Germany, on May 25-27, 1988; the proceedings of that meeting were published 1991.1 The second activity was the CSNI/PWG-3's Fracture Assessment Group's Project FALSIRE (Fracture Analyses of Large-Scale International Reference Experiments). The proceedings of the FALSIRE workshop that was held in Boston, Massachusetts, U.S.A., on May 8-10, 1990, was recently published by the Oak Ridge National Laboratory (ORNL). Those previous activities identified capabilities and shortcomings of various fracture analysis methods based on analyses of six available large-scale experiments. Different modes of fracture behavior, which ranged from brittle to ductile, were considered. In addition, geometry, size, constraint and multiaxial effects were considered. While generally good predictive capabilities were demonstrated for brittle fracture, issues were identified relative to predicting fracture behavior at higher

  4. Development and verification testing of automation and robotics for assembly of space structures

    Science.gov (United States)

    Rhodes, Marvin D.; Will, Ralph W.; Quach, Cuong C.

    1993-01-01

    A program was initiated within the past several years to develop operational procedures for automated assembly of truss structures suitable for large-aperture antennas. The assembly operations require the use of a robotic manipulator and are based on the principle of supervised autonomy to minimize crew resources. A hardware testbed was established to support development and evaluation testing. A brute-force automation approach was used to develop the baseline assembly hardware and software techniques. As the system matured and an operation was proven, upgrades were incorprated and assessed against the baseline test results. This paper summarizes the developmental phases of the program, the results of several assembly tests, the current status, and a series of proposed developments for additional hardware and software control capability. No problems that would preclude automated in-space assembly of truss structures have been encountered. The current system was developed at a breadboard level and continued development at an enhanced level is warranted.

  5. The Results of the Fourth NACEF Test for the RCCS Verification

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong-Hwan; Bae, Yoon-Yeong; Kim, Chan-Soo; Hong, Seong-Deok; Kim, Eung-Seon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    KAERI has been conducting natural convection tests in the NACEF (Natural Cooling Experimental Facility) to verify the proper functioning of the inherent passive natural cooling in the reactor cavity cooling system (RCCS) in the PMR200, a VHTR under development by the institute. The RCCS is the only ex-vessel passive safety system that should ensure the safety of the PMR200, and its performance needs to be verified. The fourth natural cooling test was conducted in the NACEF facility, the 4/17-scale RCCS mockup of the PMR200. Natural convection cooling by buoyant force formed in the risers at scaled conditions. The heat transfer coefficients at the condition of Pl{sub R} =1 appear rather higher than those estimated from both the mixed and forced correlations. The experimental data obtained from the test will be used for the validation of the system codes such as the GAMMA+ code, which will be in turn used for the reactor design.

  6. The Verification of ESF-CCS Integration Test procedure by utilizing Lab view

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jayoung; Lee, Sangseok; Sohn, Kwangyoung [Korea Reliability Technology and System, Daejeon (Korea, Republic of); Lee, Junku; Park, Geunok [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    Since the Fukushima event, especially it is considered to be important to guarantee the safety of plant by mitigating the major accident. ESF-CCS (Engineered Safety Feature-Component Control System) is monitoring all the plant variables and generates the ESF-CCS actuation signals when the plant variables violate the setpoint. Taking a look at the classic design, ESF-CCS is composed of the sub-components such as Minimum Inventory (MI), ESCM (ESF-CCS Soft Control Module), CPM, ITP, Group Controller (GC), Loop Controller (LC), CCG (Control Channel Gate), MTP, CIM (Component Interface Module). By help of Lab view simulation in integration test procedure preparation, the following benefits are attained; - Control logic and design evaluation by Lab view - Eliminating the time-consuming test case design, and determining the 'expected result' with design validation - The reliability upgrade of integration test quality.

  7. User input verification and test driven development in the NJOY21 nuclear data processing code

    Energy Technology Data Exchange (ETDEWEB)

    Trainer, Amelia Jo [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Conlin, Jeremy Lloyd [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); McCartney, Austin Paul [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-08-21

    Before physically-meaningful data can be used in nuclear simulation codes, the data must be interpreted and manipulated by a nuclear data processing code so as to extract the relevant quantities (e.g. cross sections and angular distributions). Perhaps the most popular and widely-trusted of these processing codes is NJOY, which has been developed and improved over the course of 10 major releases since its creation at Los Alamos National Laboratory in the mid-1970’s. The current phase of NJOY development is the creation of NJOY21, which will be a vast improvement from its predecessor, NJOY2016. Designed to be fast, intuitive, accessible, and capable of handling both established and modern formats of nuclear data, NJOY21 will address many issues that many NJOY users face, while remaining functional for those who prefer the existing format. Although early in its development, NJOY21 is quickly providing input validation to check user input. By providing rapid and helpful responses to users while writing input files, NJOY21 will prove to be more intuitive and easy to use than any of its predecessors. Furthermore, during its development, NJOY21 is subject to regular testing, such that its test coverage must strictly increase with the addition of any production code. This thorough testing will allow developers and NJOY users to establish confidence in NJOY21 as it gains functionality. This document serves as a discussion regarding the current state input checking and testing practices of NJOY21.

  8. 9 CFR 310.25 - Contamination with microorganisms; process control verification criteria and testing; pathogen...

    Science.gov (United States)

    2010-01-01

    ... criteria and testing; pathogen reduction standards. (a) Criteria for verifying process control; E. coli... 1 (E.coli) Establishments that slaughter more than one type of livestock or both livestock and... E. coli that is approved as an AOAC Official Method of the AOAC International (formerly the...

  9. Verification of Overall Safety Factors In Deterministic Design Of Model Tested Breakwaters

    DEFF Research Database (Denmark)

    Burcharth, H. F.

    2001-01-01

    The paper deals with concepts of safety implementation in design. An overall safety factor concept is evaluated on the basis of a reliability analysis of a model tested rubble mound breakwater with monolithic super structure. Also discussed are design load identification and failure mode limit...

  10. Verification of hybrid analysis concept of soil-foundation interaction by field vibration tests. Pt. 2

    International Nuclear Information System (INIS)

    Katayama, I.; Niwa, A.; Kubo, Y.; Penzien, J.

    1987-01-01

    The paper describes the outline of the hybrid analysis code for soil-structure interaction (HASSI) and the results of numerical simulation of the responses obtained at the model 2C in both cases of the forced vibration test and the natural earthquake excitation. (orig./HP)

  11. Verification of Emulated Channels in Multi-Probe Based MIMO OTA Testing Setup

    DEFF Research Database (Denmark)

    Fan, Wei; Carreño, Xavier; Nielsen, Jesper Ødum

    2013-01-01

    Standardization work for MIMO OTA testing methods is currently ongoing, where a multi-probe anechoic chamber based solution is an important candidate. In this paper, the probes located on an OTA ring are used to synthesize a plane wave field in the center of the OTA ring. This paper investigates...

  12. Analysis, Test and Verification in The Presence of Variability (Dagstuhl Seminar 13091)

    DEFF Research Database (Denmark)

    2014-01-01

    -aware tool chains. We brought together 46 key researchers from three continents, working on quality assurance challenges that arise from introducing variability, and some who do not work with variability, but that are experts in their respective areas in the broader domain of software analysis or testing...

  13. Verification of the analytical fracture assessments methods by a large scale pressure vessel test

    Energy Technology Data Exchange (ETDEWEB)

    Keinanen, H; Oberg, T; Rintamaa, R; Wallin, K

    1988-12-31

    This document deals with the use of fracture mechanics for the assessment of reactor pressure vessel. Tests have been carried out to verify the analytical fracture assessment methods. The analysis is focused on flaw dimensions and the scatter band of material characteristics. Results are provided and are compared to experimental ones. (TEC).

  14. CALIBRATION AND TESTING OF SONIC STIMULATION TECHNOLOGIES

    Energy Technology Data Exchange (ETDEWEB)

    Roger Turpening; Wayne Pennington; Christopher Schmidt; Sean Trisch

    2005-03-01

    In conjunction with Baker Atlas Inc. Michigan Technological University devised a system capable of recording the earth motion and pressure due to downhole and surface seismic sources. The essential elements of the system are (1) a borehole test site that will remain constant and is available all the time and for any length of time, (2) a downhole sonde that will itself remain constant and, because of its downhole digitization feature, does not require the wireline or surface recording components to remain constant, and (3) a set of procedures that ensures that the amplitude and frequency parameters of a wide range of sources can be compared with confidence. This system was used to record four seismic sources, three downhole sources and one surface source. A single activation of each of the downhole sources was not seen on time traces above the ambient noise, however, one sweep of the surface source, a small vertical vibrator, was easily seen in a time trace. One of the downhole sources was seen by means of a spike in its spectrum and a second downhole source was clearly seen after correlation and stacking. The surface vibrator produced a peak to peak particle motion signal of approximately 4.5 x 10{sup -5} cm/sec and a peak to peak pressure of approx. 2.5 x 10{sup -7} microPascals at a depth of 1,485 ft. Theoretical advances were made with our partner, Dr. Igor Beresnev at Iowa State University. A theory has been developed to account for the behavior of oil ganglia trapped in pore throats, and their ultimate release through the additional incremental pressure associated with sonic stimulation.

  15. Calibration and Testing of Sonic Stimulation Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Roger M. Turpening; Wayne D.Pennington

    2005-03-31

    In conjunction with Baker Atlas Inc. Michigan Technological University devised a system capable of recording the earth motion and pressure due to downhole and surface seismic sources. The essential elements of the system are 1) a borehole test site that will remain constant and is available all the time and for any length of time, 2) a downhole sonde that will itself remain constant and, because of its downhole digitization feature, does not require the wireline or surface recording components to remain constant, and 3) a set of procedures that ensures that the amplitude and frequency parameters of a wide range of sources can be compared with confidence. This system was used to record four seismic sources, three downhole sources and one surface source. A single activation of each of the downhole sources was not seen on time traces above the ambient noise, however, one sweep of the surface source, a small vertical vibrator, was easily seen in a time trace. One of the downhole sources was seen by means of a spike in its spectrum and a second downhole source was clearly seen after correlation and stacking. The surface vibrator produced a peak to peak particle motion signal of approximately 4.5 X 10-5 cm/sec and a peak to peak pressure of approx. 2.5 X 10-7 microPascals at a depth of 1,485 ft. Theoretical advances were made with our partner, Dr. I. Beresnev at Iowa State University. A theory has been developed to account for the behavior of oil ganglia trapped in pore throats, and their ultimate release through the additional incremental pressure associated with sonic stimulation.

  16. Ultrasonic test data acquisition and defect verification of stainless-steel welds at 4000F

    International Nuclear Information System (INIS)

    Mech, S.J.

    1983-01-01

    This paper describes techniques developed to characterize the features found during ultrasonic examination of stainless steel welds which are indicative of defects. Feature inspection technology allows reliable discrimination weld signals and other noise under remote, automatic, high temperature conditions. Ultrasonic feature inspection techniques have been successfully implemented under 400 0 F (200 0 C) flowing sodium pipe welds. The challenge is to develop techniques which find defects, but ignore variations associated with the normal cast type microstructure of the weld zone. This study was directed at gathering data on a welded pipe section with notches used to simulate defects and is an example of computer acquisition and analysis techniques of ultrasonic data. Various analysis methods were compared to find signal analysis algorithms sensitive to these simulated defects

  17. Report on results for fiscal 1996 on development of superconducting electric power application technology. Pt. 2. R and D of superconducting wire, R and D of superconducting generator, studies on total system, R and D of refrigeration system, and verification test; 1996 nendo chodendo denryoku oyo gijutsu kaihatsu seika hokokusho. 2. Chodendo senzai no kenkyu kaihatsu, chodendo hatsudenki no kenkyu kaihatsu, total system no kenkyu, reito system no kenkyu kaihatsu, jissho shiken

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-01

    In fiscal 1996, the initial cooling test and rotary excitation test were conducted for the 70,000kW slow-response type model machine, with the basic characteristics of the rotor verified such as the cooling characteristics, shaft vibration characteristics, mechanical strength, and superconductivity stability, and with the results of the studies explained. The rotor of the 70,000kW slow-response type model was installed in the test site, and the field test was carried out in 1997. For this purpose, research test was performed by the element technology of the model machine and the partial model. The technological development items, trial manufacture and test items were field winding, multi cylindrical rotor and damper. Upon the test results using the element and partial model, the design and manufacturing were implemented of the superconducting generator of a slow-response type excitation method with the output of 70,000kW class. Performed were the basic characteristic test, long-term operation test and severity test on the assumption of abnormality, verifying the characteristics and reliability of the generator as well as obtaining data concerning an excessive electromagnetic force and heat generation. From the test data and the analysis/evaluation results obtained on the model machine, the 200,000kW class pilot machine was reviewed in the conceptual design. (NEDO)

  18. Performance of multihundred-watt fueled-sphere assemblies in the safety verification test

    International Nuclear Information System (INIS)

    Cramer, E.M.

    1975-09-01

    Seven fueled-sphere assemblies equivalent to those proposed for use in multihundred-watt thermoelectric generators were subjected to conditions that simulated the sequential environments produced by an orbital abort and earth impact. The procedures were similar to those in the Safety Sequential Test, and the assemblies differed only in minor dimensional and power level changes. All assemblies met the specifications for flight quality units. Visual examination indicated that all the iridium shells had lost their containment capability; however, rupturing of two shells was not confirmed. Five were obviously ruptured, and the fuel in three was exposed. All iridium fractures were essentially intergranular. A large grain size may have promoted this type of failure. Half of the vent assemblies failed to pass helium at ambient temperature after the test. Failure was because of nonmetallic materials in the vent frits. Release of plutonia per unit area of cracks in a containment shell ruptured by simulated earth impact was determined

  19. Energy Monitoring and Control Systems--Performance Verification and Endurance Test Procedures.

    Science.gov (United States)

    1982-12-01

    EM-; tK2 s) trave h.en loadted in qvstem sit ~rp sm:l , o,1 ti-’.~ -1 rouiitthe factoz’, lest. E.VEF.NT Comnmwid the system to display the status of...contractor correction of all outstanding deficiencies . 163 TEST NO: END-i Page I of 1 OBJECTIVE: To demonstrate EMCS normal mode operation 24 TITLE: Endurance

  20. Performance test and verification of an off-the-shelf automated avian radar tracking system.

    Science.gov (United States)

    May, Roel; Steinheim, Yngve; Kvaløy, Pål; Vang, Roald; Hanssen, Frank

    2017-08-01

    Microwave radar is an important tool for observation of birds in flight and represents a tremendous increase in observation capability in terms of amount of surveillance space that can be covered at relatively low cost. Based on off-the-shelf radar hardware, automated radar tracking systems have been developed for monitoring avian movements. However, radar used as an observation instrument in biological research has its limitations that are important to be aware of when analyzing recorded radar data. This article describes a method for exploring the detection capabilities of a dedicated short-range avian radar system used inside the operational Smøla wind-power plant. The purpose of the testing described was to find the maximum detection range for various sized birds, while controlling for the effects of flight tortuosity, flight orientation relative to the radar and ground clutter. The method was to use a dedicated test target in form of a remotely controlled unmanned aerial vehicle (UAV) with calibrated radar cross section (RCS), which enabled the design of virtually any test flight pattern within the area of interest. The UAV had a detection probability of 0.5 within a range of 2,340 m from the radar. The detection performance obtained by the RCS-calibrated test target (-11 dBm 2 , 0.08 m 2 RCS) was then extrapolated to find the corresponding performance of differently sized birds. Detection range depends on system sensitivity, the environment within which the radar is placed and the spatial distribution of birds. The avian radar under study enables continuous monitoring of bird activity within a maximum range up to 2 km dependent on the size of the birds in question. While small bird species may be detected up to 0.5-1 km, larger species may be detected up to 1.5-2 km distance from the radar.

  1. Verification of dissolution test for doxycycline hyclate in capsules to implement into the pharmacopoeial monograph

    OpenAIRE

    Dobrova, Anna; Golovchenko, Olga; Georgiyants, Victoria

    2018-01-01

    The study of dissolution profiles is important as a cheap and easy supplement to bioequivalence research, and as a variation to such studies. This method is not outlined in the State Pharmacopoeia of Ukraine for the doxycycline capsules. Therefore, according to the current requirements, it was necessary to verify the procedure recommended by the US Pharmacopeia to confirm that this laboratory test will be reproduced correctly, and to use it in our further studies.The aim of our research was t...

  2. Nuclear Data Verification and Standardization

    Energy Technology Data Exchange (ETDEWEB)

    Karam, Lisa R.; Arif, Muhammad; Thompson, Alan K.

    2011-10-01

    The objective of this interagency program is to provide accurate neutron interaction verification and standardization data for the U.S. Department of Energy Division of Nuclear Physics programs which include astrophysics, radioactive beam studies, and heavy-ion reactions. The measurements made in this program are also useful to other programs that indirectly use the unique properties of the neutron for diagnostic and analytical purposes. These include homeland security, personnel health and safety, nuclear waste disposal, treaty verification, national defense, and nuclear based energy production. The work includes the verification of reference standard cross sections and related neutron data employing the unique facilities and capabilities at NIST and other laboratories as required; leadership and participation in international intercomparisons and collaborations; and the preservation of standard reference deposits. An essential element of the program is critical evaluation of neutron interaction data standards including international coordinations. Data testing of critical data for important applications is included. The program is jointly supported by the Department of Energy and the National Institute of Standards and Technology.

  3. Review of waste package verification tests. Semiannual report, April 1985-September 1985

    International Nuclear Information System (INIS)

    Soo, P.

    1986-01-01

    Several studies were completed this period to evaluate experimental and analytical methodologies being used in the DOE waste package program. The first involves a determination of the relevance of the test conditions being used by DOE to characterize waste package component behavior in a salt repository system. Another study focuses on the testing conditions and procedures used to measure radionuclide solubility and colloid formation in repository groundwaters. An attempt was also made to evaluate the adequacy of selected waste package performance codes. However, the latter work was limited by an inability to obtain several codes from DOE. Nevertheless, it was possible to comment briefly on the structures and intents of the codes based on publications in the open literature. The final study involved an experimental program to determine the likelihood of stress-corrosion cracking of austenitic stainless steels and Incoloy 825 in simulated tuff repository environments. Tests for six-month exposure periods in water and air-steam conditions are described. 52 figs., 48 tabs

  4. The Savannah River environmental technology field test platform

    International Nuclear Information System (INIS)

    Rossabi, J.; Riha, B.D.

    1995-01-01

    The principal goal in the development of new technologies for environmental monitoring and characterization is transferring them to organizations and individuals for use in site assessment and compliance monitoring. The Savannah River technology Center (SRTC) has been developing a program to rigorously field test promising environmental technologies that have not undergone EPA equivalency testing. The infrastructure and staff expertise developed as part of the activities of the Savannah River Integrated Demonstration Program allows field testing of technologies without the difficulties of providing remote field support. By providing a well-characterized site and a well-developed infrastructure, technologies are tested in actual field scenarios to determine their appropriate applications in environmental characterization and monitoring activities. The field tests provide regulatory organizations, potential industrial partners, and potential users with the opportunity to evaluate the technology's performance and its utility for implementation in environmental characterization and monitoring programs. This program has resulted in the successful implementation of several new technologies

  5. Verification and Demonstration for Transition of Nonhexavalent Chromium, Low-Volatile Organic Compound (VOC) Alternative Technologies to Replace DOD-P-15328 Wash Primer for Multimetal Applications

    Science.gov (United States)

    2017-09-28

    Technical Report 3. DATES COVERED (From - To) October 2012–September 2017 4. TITLE AND SUBTITLE Verification and Demonstration for Transition of...surfaces to protect against corrosion and improve the adhesion of the subsequent primer to the base metal. The wash primer contains hexavalent chromium (Cr...Adhesion 6 2.3 Dry Tape Adhesion 7 2.4 Pencil Hardness 8 2.5 Chip Resistance Test 8 2.6 Accelerated Corrosion Testing 10 2.7 Outdoor Exposure Testing at

  6. Study on dynamic rod worth measurement method and its test verification

    International Nuclear Information System (INIS)

    Wu Lei; Liu Tongxian; Zhao Wenbo; Li Songling; Yu Yingrui

    2015-01-01

    An advanced rod worth measurement technique, the dynamic rod worth measurement method (DRWM) has been developed. Static Spatial Factors (SSF) and Dynamic Spatial Factor (DSF) were introduced to improve the inverse kinetics method. The three dimensional steady and transient simulations for the measurement process was carried out to calculate the modification factors. The rod worth measurement, test was performed on a research reactor to verify DRWM. The results showed that the DRWM method provided the improved accuracy and could be a replacement of the traditional methods. (authors)

  7. Optical verification tests of the NISP/Euclid grism qualification model

    Science.gov (United States)

    Caillat, Amandine; Costille, Anne; Pascal, Sandrine; Vives, Sébastien; Rossin, Christelle; Sanchez, Patrice; Foulon, Benjamin

    2016-07-01

    The Euclid space mission aims at elucidating dark matter and dark energy mysteries thanks to two scientific instruments: VIS, the visible camera and NISP, the Near Infrared Spectro-Photometer. Millions of galaxies spectra will be recorded thanks to its spectroscopic mode using four grisms developed under LAM (Laboratoire d'Astrophysique de Marseille) responsibility. These dispersive optical components are made of a grating on a prism and include also, specifically for NISP, three other optical functions: spectral filtering, focus adjustment and spectral wavefront correction. Therefore, these optical elements are very challenging to manufacture (four industrial partners work on a single optical component) and to test before integration into NISP. In this paper, first we describe the optical specifications and the manufacturing process. Second, we explain the optical validation tests campaign: optical setups, measurements and data processing procedures used to validate these complex optical components, particularly for transmitted efficiency and wavefront error for which specifications are very stringent. Finally, we present the first results obtained on the grism EQM which manufacturing is on-going and almost finished.

  8. Selection of a leaching test method for waste product conformity verification

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Isabel Sofia R.F.S.; Tello, Clédola Cássia O.; Haucz, Maria Judite A., E-mail: isabel.lopes@cdtn.br, E-mail: tellocc@cdtn.br, E-mail: hauczmj@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    A study on the waste acceptance criteria (WAC) for disposal in a near-surface repository is being implemented by CDTN / CNEN. The acceptance criteria are used to ensure the safety in the repository facility in order to protect the employees, the public and the environment from some possible harmful and dangerous effects of the ionizing radiation. A near-surface repository is intended to be built for disposal of the Brazilian low- and intermediate level wastes. Leaching was the criterion chosen to be studied in this research. It is extremely important for the safety assessment to evaluate the waste form in relation to the radionuclides release, to predict the repository performance in the long term. As in the Brazilian WAC the test to measure the radionuclides leaching is not defined yet, two leaching tests were selected to be performed, the ISO 6961 and the ASTM C1308. The results will be analyzed in order to verify their similarities and differences and also their advantages and disadvantages. Inactive tracers cesium and lead were used as tracers to follow the leaching in both procedures. (author)

  9. Selection of a leaching test method for waste product conformity verification

    International Nuclear Information System (INIS)

    Lopes, Isabel Sofia R.F.S.; Tello, Clédola Cássia O.; Haucz, Maria Judite A.

    2017-01-01

    A study on the waste acceptance criteria (WAC) for disposal in a near-surface repository is being implemented by CDTN / CNEN. The acceptance criteria are used to ensure the safety in the repository facility in order to protect the employees, the public and the environment from some possible harmful and dangerous effects of the ionizing radiation. A near-surface repository is intended to be built for disposal of the Brazilian low- and intermediate level wastes. Leaching was the criterion chosen to be studied in this research. It is extremely important for the safety assessment to evaluate the waste form in relation to the radionuclides release, to predict the repository performance in the long term. As in the Brazilian WAC the test to measure the radionuclides leaching is not defined yet, two leaching tests were selected to be performed, the ISO 6961 and the ASTM C1308. The results will be analyzed in order to verify their similarities and differences and also their advantages and disadvantages. Inactive tracers cesium and lead were used as tracers to follow the leaching in both procedures. (author)

  10. Review of waste package verification tests. Semiannual report, October 1984-March 1985

    International Nuclear Information System (INIS)

    Soo, P.

    1985-07-01

    The potential of WAPPA, a second-generation waste package system code, to meet the needs of the regulatory community is analyzed. The analysis includes an indepth review of WAPPA's individual process models and a review of WAPPA's operation. It is concluded that the code is of limited use to the NRC in the present form. Recommendations for future improvement, usage, and implementation of the code are given. This report also describes the results of a testing program undertaken to determine the chemical environment that will be present near a high-level waste package emplaced in a basalt repository. For this purpose, low carbon 1020 steel (a current BWIP reference container material), synthetic basaltic groundwater and a mixture of bentonite and basalt were exposed, in an autoclave, to expected conditions some period after repository sealing (150 0 C, approx. =10.4 MPa). Parameters measured include changes in gas pressure with time and gas composition, variation in dissolved oxygen (DO), pH and certain ionic concentrations of water in the packing material across an imposed thermal gradient, mineralogic alteration of the basalt/bentonite mixture, and carbon steel corrosion behavior. A second testing program was also initiated to check the likelihood of stress corrosion cracking of austenitic stainless steels and Incoloy 825 which are being considered for use as waste container materials in the tuff repository program. 82 refs., 70 figs., 27 tabs

  11. System Description: Embedding Verification into Microsoft Excel

    OpenAIRE

    Collins, Graham; Dennis, Louise Abigail

    2000-01-01

    The aim of the PROSPER project is to allow the embedding of existing verification technology into applications in such a way that the theorem proving is hidden, or presented to the end user in a natural way. This paper describes a system built to test whether the PROSPER toolkit satisfied this aim. The system combines the toolkit with Microsoft Excel, a popular commercial spreadsheet application.

  12. Reload core safety verification

    International Nuclear Information System (INIS)

    Svetlik, M.; Minarcin, M.

    2003-01-01

    This paper presents a brief look at the process of reload core safety evaluation and verification in Slovak Republic. It gives an overview of experimental verification of selected nuclear parameters in the course of physics testing during reactor start-up. The comparison of IAEA recommendations and testing procedures at Slovak and European nuclear power plants of similar design is included. An introduction of two level criteria for evaluation of tests represents an effort to formulate the relation between safety evaluation and measured values (Authors)

  13. Particularities of Verification Processes for Distributed Informatics Applications

    Directory of Open Access Journals (Sweden)

    Ion IVAN

    2013-01-01

    Full Text Available This paper presents distributed informatics applications and characteristics of their development cycle. It defines the concept of verification and there are identified the differences from software testing. Particularities of the software testing and software verification processes are described. The verification steps and necessary conditions are presented and there are established influence factors of quality verification. Software optimality verification is analyzed and some metrics are defined for the verification process.

  14. Hypervelocity technology carbon/carbon testing

    Science.gov (United States)

    Anselmo, John V.; Kretz, Lawrence O.

    The paper describes the procedures used at the Structures Test Laboratory of the Wright Laboratory's Flight Dynamics Directorate to test a carbon/carbon hot structure representing a typical hypersonic gliding body, and presents the results of tests. The forebody was heated to 1371 C over 13 test runs, using radiant quartz lamps; a vertical shear force of 5.34 kN was introduced to the nose at a stabilized temperature of 816 C. Test data were collected using prototype high-temperature strain gages, in-house-designed high-temperature extensometers, conventional strain gages, and thermocouples. Video footage was taken of all test runs. Test runs were successfully completed up to 1371 C with flight typical thermal gradients at heating rates up to 5.56 C/sec. Results showed that, overall, the termal test control systems performed as predicted and that test temperatures and thermal gradients were achieved to within about 5 percent in most cases.

  15. Verification test for helium panel of cryopump for DIII-D advanced divertor

    International Nuclear Information System (INIS)

    Baxi, C.B.; Laughon, G.J.; Langhorn, A.R.; Schaubel, K.M.; Smith, J.P.; Gootgeld, A.M.; Campbell, G.L.; Menon, M.M.

    1992-01-01

    It is planned to install a cryogenic pump in the lower divertor portion of the DIII-D tokamak with a pumping speed of 50000 ell/s and an exhaust of 2670 Pa-ell/s (20 Torr-ell/s). A coaxial counter flow configuration has been chosen for the helium panel of this cryogenic pump. This paper evaluates cool-down rates and fluid stability of this configuration. A prototypic test was performed at General Atomics (GA) to increase confidence in the design. It was concluded that the helium panel cooldown rate agreed quite well with analytical prediction and was within acceptable limits. The design flow rate proved stable and two-phase pressure drop can be predicted quite accurately

  16. Verification test for helium panel of cryopump for DIII-D advanced divertor

    International Nuclear Information System (INIS)

    Baxi, C.B.; Laughon, G.J.; Langhorn, A.R.; Schaubel, K.M.; Smith, J.P.; Gootgeld, A.M.; Campbell, G.L.; Menon, M.M.

    1991-10-01

    It is planned to install a cryogenic pump in the lower divertor portion of the D3-D tokamak with a pumping speed of 50000 ell/s and an exhaust of 2670 Pa-ell/s (20 Torr-ell s). A coaxial counter flow configuration has been chosen for the helium panel of this cryogenic pump. This paper evaluates cooldown rates and fluid stability of this configuration. A prototypic test was performed at General Atomics (GA) to increase confidence in the design. It was concluded that the helium panel cooldown rate agreed quite well with analytical prediction and was within acceptable limits. The design flow rate proved stable and two-phase pressure drop can be predicted quite accurately. 8 refs., 5 figs., 1 tab

  17. Creep crack growth verification testing in alloy 800H tubular components

    International Nuclear Information System (INIS)

    Hunter, C.P.; Hurst, R.C.

    1992-01-01

    A method for determining the creep crack growth, CCG, and stress rupture behaviour of Alloy 800H tubular components containing longitudinal notches at 800deg C is described. The presence of the notch is found to systematically weaken the tube, the degree of weaking dependent upon the notch length and depth. The creep crack growth rates, determined from a specially adapted potential drop technique are compared with those obtained from conventional compact tension type specimens. Using the stress intensity factor, K 1 , and the C * parameter as the basis of comparison it is found that the latter gives excellent correlation between the specimen and component behaviour. Finally attention is drawn to the potential dangers of predicting the component creep crack growth behaviour from the data obtained using conventional specimens for a structure sensitive material such as Alloy 800H and conversely to the advantages of the component type CCG tests developed in the present work. (orig.)

  18. Verification of maximum impact force for interim storage cask for the Fast Flux Testing Facility

    International Nuclear Information System (INIS)

    Chen, W.W.; Chang, S.J.

    1996-01-01

    The objective of this paper is to perform an impact analysis of the Interim Storage Cask (ISC) of the Fast Flux Test Facility (FFTF) for a 4-ft end drop. The ISC is a concrete cask used to store spent nuclear fuels. The analysis is to justify the impact force calculated by General Atomics (General Atomics, 1994) using the ILMOD computer code. ILMOD determines the maximum force developed by the concrete crushing which occurs when the drop energy has been absorbed. The maximum force, multiplied by the dynamic load factor (DLF), was used to determine the maximum g-level on the cask during a 4-ft end drop accident onto the heavily reinforced FFTF Reactor Service Building's concrete surface. For the analysis, this surface was assumed to be unyielding and the cask absorbed all the drop energy. This conservative assumption simplified the modeling used to qualify the cask's structural integrity for this accident condition

  19. Experimental verification of the CLIC Decelerator with the test Beam Line in the CLIC test facility 3

    CERN Document Server

    Lillestøl, R L; Olvegård, M; Rabiller, A N; Sterbini, G; Adli, E

    2012-01-01

    The Test Beam Line in the CLIC Test Facility 3 is the first prototype of the CLIC drive beam decelerator. The main purpose of the experiment is to demonstrate efficient 12 GHz rf power production and stable transport of an electron drive beam during deceleration. The Test Beam Line consists of a FODO structure with high precision BPMs and quadrupoles mounted on mechanical movers for precisebeam alignment. Nine out of the planned 16 Power Extraction and Transfer Structures have currently been installed and commissioned. We correlate rf power production measurements with the drive beam deceleration measurements, and compare the two measurements to the theoretical predictions. We also discuss the impact of the drive beam bunch length and bunch combination on the measurements.

  20. Report on achievements in fiscal 1999 of energy and environment technology verification project formation assisting project and international joint verification and research project. Verification of discrete power generation system utilizing mini-power generation that utilizes micro gas turbine; 1999 nendo micro gas turbine riyo mini hatsuden wo riyoshita bunsangata hatsuden system no kensho seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    This paper describes the verification test on power generation by using natural gas driven micro gas turbines (rated at 28 kW) in Thailand. The turbine presented excellent result of providing a maximum power generation output of 25 kW, having no efficiency deterioration even at the 50% output point (about 22%). Its exhaust gas emitted under the normal operation is clean. The waste heat is as low as 290 degrees C, which can be used for hot water supply, but may be difficult for steam generation. Under the severe condition for building large power plants in remote areas due to environmental issues and power transmission loss, proliferation of the discrete power generation system in the suburbs of the city of Bangkok draws expectation. This system can be more advantageous than the existing facilities if the end user gas price is 6.7 Bht/m{sup 3} or less. Discussions were given on a hybrid electric vehicle (HEV) bus driven by electric power generated from the gas turbine mounted on the bus. The bus is overwhelmingly superior in the environmental aspect to diesel fueled buses. The HEV bus emits no black smoke at all, and NOx emission is as low as about 1/70. Fuel consumption is less than half (when regenerative braking is used). However, the vehicle body cost is higher by 40%. Smooth operation of the buses requires indispensably deployment of compressed natural gas service stations (to be located at 40-km interval ideally). Assistance is required also on the fund for gas line installations, and civil engineering construction technologies. (NEDO)

  1. Verification of a TRACE EPRTM model on the basis of a scaling calculation of an SBLOCA ROSA test

    International Nuclear Information System (INIS)

    Freixa, J.; Manera, A.

    2011-01-01

    Research highlights: → Verification of a TRACE input deck for the EPR TM generation III PWR. → Scaling simulation of an SBLOCA experiment of the integral test facility ROSA/LSTF. → The EPR TM model was compared with the TRACE results of the ROSA/LSTF model. - Abstract: In cooperation with the Finnish Radiation and Nuclear Safety Authority (STUK), a project has been launched at the Paul Scherrer Institute (PSI) aimed at performing safety evaluations of the Olkiluoto-3 nuclear power plant (NPP), the first EPR TM , a generation III pressurizer water reactor (PWR); with particular emphasis on small-and large-break loss-of-coolant-accidents (SB/LB-LOCAs) and main steam-line breaks. As a first step of this work, the best estimate system code TRACE has been used to develop a model of Olkiluoto-3. In order to test the nodalization, a scaling calculation from the rig of safety assessment (ROSA) test facility has been performed. The ROSA large scale test facility (LSTF) was built to simulate Westinghouse design pressurized water reactors (PWR) with a four-loop configuration. Even though there are differences between the EPR TM and the Westinghouse designs, the number of similarities is large enough to carry out scaling calculations on SBLOCA and LOCA cases from the ROSA facility; as a matter of fact, the main differences are located in the secondary side. Test 6-1 of the ROSA 1 programme, an SBLOCA with the break situated in the upper head of the reactor pressure vessel (RPV), was of special interest since a very good agreement with the experiment was obtained with a TRACE input deck. In order to perform such scaling calculation, the set-points of the secondary relief and safety valves in the EPR TM nodalization had to be changed to those used in the ROSA facility, the break size and the core power had to be scaled by a factor of 60 (according to the core power and core volume) and the pumps coast down had to be adapted to the ones of the test. The calculation showed

  2. Verification of the code ATHLET by post-test analysis of two experiments performed at the CCTF integral test facility

    International Nuclear Information System (INIS)

    Krepper, E.; Schaefer, F.

    2001-03-01

    In the framework of the external validation of the thermohydraulic code ATHLET Mod 1.2 Cycle C, which has been developed by the GRS, post test analyses of two experiments were done, which were performed at the japanese test facility CCTF. The test facility CCTF is a 1:25 volume-scaled model of a 1000 MW pressurized water reactor. The tests simulate a double end break in the cold leg of the PWR with ECC injection into the cold leg and with combined ECC injection into the hot and cold legs. The evaluation of the calculated results shows, that the main phenomena can be calculated in a good agreement with the experiment. Especially the behaviour of the quench front and the core cooling are calculated very well. Applying a two-channel representation of the reactor model the radial behaviour of the quench front could be reproduced. Deviations between calculations and experiment can be observed simulating the emergency injection in the beginning of the transient. Very high condensation rates were calculated and the pressure decrease in this phase of the transient is overestimated. Besides that, the pressurization due to evaporation in the refill phase is underestimated by ATHLET. (orig.) [de

  3. ON-LINE MONITORING OF I&C TRANSMITTERS AND SENSORS FOR CALIBRATION VERIFICATION AND RESPONSE TIME TESTING WAS SUCCESSFULLY IMPLEMENTED AT ATR

    Energy Technology Data Exchange (ETDEWEB)

    Erickson, Phillip A.; O' Hagan, Ryan; Shumaker, Brent; Hashemian, H. M.

    2017-03-01

    The Advanced Test Reactor (ATR) has always had a comprehensive procedure to verify the performance of its critical transmitters and sensors, including RTDs, and pressure, level, and flow transmitters. These transmitters and sensors have been periodically tested for response time and calibration verification to ensure accuracy. With implementation of online monitoring techniques at ATR, the calibration verification and response time testing of these transmitters and sensors are verified remotely, automatically, hands off, include more portions of the system, and can be performed at almost any time during process operations. The work was done under a DOE funded SBIR project carried out by AMS. As a result, ATR is now able to save the manpower that has been spent over the years on manual calibration verification and response time testing of its temperature and pressure sensors and refocus those resources towards more equipment reliability needs. More importantly, implementation of OLM will help enhance the overall availability, safety, and efficiency. Together with equipment reliability programs of ATR, the integration of OLM will also help with I&C aging management goals of the Department of Energy and long-time operation of ATR.

  4. LEGO plot for simultaneous application of multiple quality requirements during trueness verification of quantitative laboratory tests.

    Science.gov (United States)

    Park, Hae-il; Chae, Hyojin; Kim, Myungshin; Lee, Jehoon; Kim, Yonggoo

    2014-03-01

    We developed a two-dimensional plot for viewing trueness that takes into account potential shift and variable quality requirements to verify trueness using certified reference material (CRM). Glucose, total cholesterol (TC), and creatinine levels were determined by two kinds of assay in two levels of a CRM. Available quality requirements were collected, codified, and sorted in an ascending order in the plot's header row. Centering on the mean of measured values from CRM, the "mean ± US CLIA '88 allowable total error" was located in the header of the leftmost and rightmost columns. Twenty points were created in intervening columns as potential shifts. Uncertainties were calculated according to regression between certified values and uncertainties of CRM, and positioned in the corresponding columns. Cells were assigned different colors where column and row intersected based on comparison of the 95% confidence interval of the percentage bias with each quality requirement. A glucose assay failed to meet the highest quality criteria, for which shift of +0.13-0.14 mmol/l was required. A TC assay met the quality requirement and a shift of ±0.03 mmol/l was tolerable. A creatinine assay also met the quality requirement but any shift was not tolerable. The plot provides a systematic view of the trueness of quantitative laboratory tests. © 2014 Wiley Periodicals, Inc.

  5. Development and verification test on remote plasma cutting of large metallic waste

    International Nuclear Information System (INIS)

    Ozawa, Tamotsu; Yamada, Kunitaka; Abe, Tadashi

    1979-01-01

    Plasma cutting is the cutting method to melt and scatter cut objects by generating arc between an electrode in a nozzle and the cut objects and making working gas fed to surround it into high temperature, high speed plasma jet. In case of remote plasma cutting, a torch for the plasma cutting is operated remotely with a manipulator from the outside of a cell. At the time of planning the method of breaking up solid wastes, the type of cutting machines and the method of remote operation of the cutting machines and cut objects were examined. It was decided to adopt plasma cutting machines, because their cutting capability such as materials, thickness and cutting speed is excellent, and the construction and handling are simple. The form of the solid wastes to be cut is not uniform, accordingly the method of manipulator operation was adopted to respond to various forms flexibly. Cut objects are placed on a turntable to change the position successively. In case of remote plasma cutting, the controls of torch speed and gap must be made with a manipulator. The use of light-shielding glasses reduces largely the watchability of cut objects and becomes hindrance in the operation. As for the safety aspect, the suitable gas for cutting, which does not contain hydrogen, must be selected. The tests carried out for two years since November, 1977, are reported in this paper, and most of the problems have been solved. (Kako, I.)

  6. Radball Technology Testing For Hot Cell Characterization

    International Nuclear Information System (INIS)

    Farfan, E.; Jannik, T.

    2010-01-01

    Operations at various U.S. Department of Energy sites have resulted in substantial radiological contamination of tools, equipment, and facilities. It is essential to use remote technologies for characterization and decommissioning to keep worker exposures as low as reasonably achievable in these highly contaminated environments. A significant initial step in planning and implementing D and D of contaminated facilities involves the development of an accurate assessment of the radiological, chemical, and structural conditions inside of the facilities. Collected information describing facility conditions using remote technologies could reduce the conservatism associated with planning initial worker entry (and associated cost).

  7. PCR-based verification of positive rapid diagnostic tests for intestinal protozoa infections with variable test band intensity.

    Science.gov (United States)

    Becker, Sören L; Müller, Ivan; Mertens, Pascal; Herrmann, Mathias; Zondie, Leyli; Beyleveld, Lindsey; Gerber, Markus; du Randt, Rosa; Pühse, Uwe; Walter, Cheryl; Utzinger, Jürg

    2017-10-01

    Stool-based rapid diagnostic tests (RDTs) for pathogenic intestinal protozoa (e.g. Cryptosporidium spp. and Giardia intestinalis) allow for prompt diagnosis and treatment in resource-constrained settings. Such RDTs can improve individual patient management and facilitate population-based screening programmes in areas without microbiological laboratories for confirmatory testing. However, RDTs are difficult to interpret in case of 'trace' results with faint test band intensities and little is known about whether such ambiguous results might indicate 'true' infections. In a longitudinal study conducted in poor neighbourhoods of Port Elizabeth, South Africa, a total of 1428 stool samples from two cohorts of schoolchildren were examined on the spot for Cryptosporidium spp. and G. intestinalis using an RDT (Crypto/Giardia DuoStrip; Coris BioConcept). Overall, 121 samples were positive for G. intestinalis and the RDT suggested presence of cryptosporidiosis in 22 samples. After a storage period of 9-10 months in cohort 1 and 2-3 months in cohort 2, samples were subjected to multiplex PCR (BD Max™ Enteric Parasite Panel, Becton Dickinson). Ninety-three percent (112/121) of RDT-positive samples for G. intestinalis were confirmed by PCR, with a correlation between RDT test band intensity and quantitative pathogen load present in the sample. For Cryptosporidium spp., all positive RDTs had faintly visible lines and these were negative on PCR. The performance of the BD Max™ PCR was nearly identical in both cohorts, despite the prolonged storage at disrupted cold chain conditions in cohort 1. The Crypto/Giardia DuoStrip warrants further validation in communities with a high incidence of diarrhoea. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Laboratory Testing and Performance Verification of the CHARIS Integral Field Spectrograph

    Science.gov (United States)

    Groff, Tyler D.; Chilcote, Jeffrey; Kasdin, N. Jeremy; Galvin, Michael; Loomis, Craig; Carr, Michael A.; Brandt, Timothy; Knapp, Gillian; Limbach, Mary Anne; Guyon, Olivier; hide

    2016-01-01

    delivered to the Subaru telescope in April 2016. This paper is a report on the laboratory performance of the spectrograph, and its current status in the commissioning process so that observers will better understand the instrument capabilities. We will also discuss the lessons learned during the testing process and their impact on future high-contrast imaging spectrographs for wavefront control.

  9. Development of an Autonomous Navigation Technology Test Vehicle

    National Research Council Canada - National Science Library

    Tobler, Chad K

    2004-01-01

    .... In order to continue these research activities at CIMAR, a new Kawasaki Mule All-Terrain Vehicle was chosen to be automated as a test-bed for the purpose of developing and testing autonomous vehicle technologies...

  10. Enraf Series 854 advanced technology gauge (ATG) acceptance test procedure

    International Nuclear Information System (INIS)

    Huber, J.H.

    1996-01-01

    This Acceptance Test Procedure was written to test the Enraf Series 854 Advanced Technology Gauge (ATG) prior to installation in the Tank Farms. The procedure sets various parameters and verifies that the gauge is functional

  11. ITER: a technology test bed for a fusion reactor

    International Nuclear Information System (INIS)

    Huguet, M.; Green, B.J.

    1996-01-01

    The ITER Project aims to establish nuclear fusion as an energy source that has potential safety and environmental advantages, and to develop the technologies required for a fusion reactor. ITER is a collaborative project between the European Union, Japan, the Russian Federation and the United States of America. During the current phase of the Project, an R and D programme of about 850 million dollars is underway to develop the technologies required for ITER. This technological effort should culminate in the construction of the components and systems of the ITER machine and its auxiliaries. The main areas of technological development include the first wall and divertor technology, the blanket technology and tritium breeding, superconducting magnet technology, pulsed power technology and remote handling. ITER is a test bed and an essential step to establish the technology of future fusion reactors. Many of the ITER technologies are of potential interest to other fields and their development is expected to benefit the industries involved. (author)

  12. Projected Impact of Compositional Verification on Current and Future Aviation Safety Risk

    Science.gov (United States)

    Reveley, Mary S.; Withrow, Colleen A.; Leone, Karen M.; Jones, Sharon M.

    2014-01-01

    The projected impact of compositional verification research conducted by the National Aeronautic and Space Administration System-Wide Safety and Assurance Technologies on aviation safety risk was assessed. Software and compositional verification was described. Traditional verification techniques have two major problems: testing at the prototype stage where error discovery can be quite costly and the inability to test for all potential interactions leaving some errors undetected until used by the end user. Increasingly complex and nondeterministic aviation systems are becoming too large for these tools to check and verify. Compositional verification is a "divide and conquer" solution to addressing increasingly larger and more complex systems. A review of compositional verification research being conducted by academia, industry, and Government agencies is provided. Forty-four aviation safety risks in the Biennial NextGen Safety Issues Survey were identified that could be impacted by compositional verification and grouped into five categories: automation design; system complexity; software, flight control, or equipment failure or malfunction; new technology or operations; and verification and validation. One capability, 1 research action, 5 operational improvements, and 13 enablers within the Federal Aviation Administration Joint Planning and Development Office Integrated Work Plan that could be addressed by compositional verification were identified.

  13. Verification of the thermal design of electronic equipment

    Energy Technology Data Exchange (ETDEWEB)

    Hienonen, R.; Karjalainen, M.; Lankinen, R. [VTT Automation, Espoo (Finland). ProTechno

    1997-12-31

    The project `Verification of the thermal design of electronic equipment` studied the methodology to be followed in the verification of thermal design of electronic equipment. This project forms part of the `Cool Electronics` research programme funded by TEKES, the Finnish Technology Development Centre. This project was carried out jointly by VTT Automation, Lappeenranta University of Technology, Nokia Research Center and ABB Industry Oy VSD-Technology. The thermal design of electronic equipment has a significant impact on the cost, reliability, tolerance to different environments, selection of components and materials, and ergonomics of the product. This report describes the method for verification of thermal design. It assesses the goals set for thermal design, environmental requirements, technical implementation of the design, thermal simulation and modelling, and design qualification testing and the measurements needed. The verification method covers all packaging levels of electronic equipment from the system level to the electronic component level. The method described in this report can be used as part of the quality system of a corporation. The report includes information about the measurement and test methods needed in the verification process. Some measurement methods for the temperature, flow and pressure of air are described. (orig.) Published in Finnish VTT Julkaisuja 824. 22 refs.

  14. Nuclear disarmament verification

    International Nuclear Information System (INIS)

    DeVolpi, A.

    1993-01-01

    Arms control treaties, unilateral actions, and cooperative activities -- reflecting the defusing of East-West tensions -- are causing nuclear weapons to be disarmed and dismantled worldwide. In order to provide for future reductions and to build confidence in the permanency of this disarmament, verification procedures and technologies would play an important role. This paper outlines arms-control objectives, treaty organization, and actions that could be undertaken. For the purposes of this Workshop on Verification, nuclear disarmament has been divided into five topical subareas: Converting nuclear-weapons production complexes, Eliminating and monitoring nuclear-weapons delivery systems, Disabling and destroying nuclear warheads, Demilitarizing or non-military utilization of special nuclear materials, and Inhibiting nuclear arms in non-nuclear-weapons states. This paper concludes with an overview of potential methods for verification

  15. Verification and validation of the PLTEMP/ANL code for thermal hydraulic analysis of experimental and test reactors

    International Nuclear Information System (INIS)

    Kalimullah, M.; Olson, A.O.; Feldman, E.E.; Hanan, N.; Dionne, B.

    2012-01-01

    The document compiles in a single volume several verification and validation works done for the PLTEMP/ANL code during the years of its development and improvement. Some works that are available in the open literature are simply referenced at the outset, and are not included in the document. PLTEMP has been used in conversion safety analysis reports of several US and foreign research reactors that have been licensed and converted. A list of such reactors is given. Each chapter of the document deals with the verification or validation of a specific model. The model verification is usually done by comparing the code with hand calculation, Microsoft spreadsheet calculation, or Mathematica calculation. The model validation is done by comparing the code with experimental data or a more validated code like the RELAP5 code.

  16. Verification and Validation of the PLTEMP/ANL Code for Thermal-Hydraulic Analysis of Experimental and Test Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Kalimullah, M. [Argonne National Lab. (ANL), Argonne, IL (United States); Olson, Arne P. [Argonne National Lab. (ANL), Argonne, IL (United States); Feldman, E. E. [Argonne National Lab. (ANL), Argonne, IL (United States); Hanan, N. [Argonne National Lab. (ANL), Argonne, IL (United States); Dionne, B. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-04-07

    The document compiles in a single volume several verification and validation works done for the PLTEMP/ANL code during the years of its development and improvement. Some works that are available in the open literature are simply referenced at the outset, and are not included in the document. PLTEMP has been used in conversion safety analysis reports of several US and foreign research reactors that have been licensed and converted. A list of such reactors is given. Each chapter of the document deals with the verification or validation of a specific model. The model verification is usually done by comparing the code with hand calculation, Microsoft spreadsheet calculation, or Mathematica calculation. The model validation is done by comparing the code with experimental data or a more validated code like the RELAP5 code.

  17. Verification study on technology for preliminary investigation for HLW geological disposal. Part 2. Verification of surface geophysical prospecting through establishing site descriptive models

    International Nuclear Information System (INIS)

    Kondo, Hirofumi; Suzuki, Koichi; Hasegawa, Takuma; Goto, Keiichiro; Yoshimura, Kimitaka; Muramoto, Shigenori

    2012-01-01

    The Yokosuka demonstration and validation project using Yokosuka CRIEPI site has been conducted since FY 2006 as a cooperative research between NUMO (Nuclear Waste Management Organization of Japan) and CRIEPI. The objectives of this project are to examine and to refine the basic methodology of the investigation and assessment of properties of geological environment in the stage of Preliminary Investigation for HLW geological disposal. Within Preliminary Investigation technologies, surface geophysical prospecting is an important means of obtaining information from deep geological environment for planning borehole surveys. In FY 2010, both seismic prospecting (seismic reflection and vertical seismic profiling methods) for obtaining information about geological structure and electromagnetic prospecting (magneto-telluric and time domain electromagnetic methods) for obtaining information about resistivity structure reflecting the distribution of salt water/fresh water boundary to a depth of over several hundred meters were conducted in the Yokosuka CRIEPI site. Through these surveys, the contribution of geophysical prospecting methods in the surface survey stage to improving the reliability of site descriptive models was confirmed. (author)

  18. Verification of Ceramic Structures

    Science.gov (United States)

    Behar-Lafenetre, Stephanie; Cornillon, Laurence; Rancurel, Michael; De Graaf, Dennis; Hartmann, Peter; Coe, Graham; Laine, Benoit

    2012-07-01

    In the framework of the “Mechanical Design and Verification Methodologies for Ceramic Structures” contract [1] awarded by ESA, Thales Alenia Space has investigated literature and practices in affiliated industries to propose a methodological guideline for verification of ceramic spacecraft and instrument structures. It has been written in order to be applicable to most types of ceramic or glass-ceramic materials - typically Cesic®, HBCesic®, Silicon Nitride, Silicon Carbide and ZERODUR®. The proposed guideline describes the activities to be performed at material level in order to cover all the specific aspects of ceramics (Weibull distribution, brittle behaviour, sub-critical crack growth). Elementary tests and their post-processing methods are described, and recommendations for optimization of the test plan are given in order to have a consistent database. The application of this method is shown on an example in a dedicated article [7]. Then the verification activities to be performed at system level are described. This includes classical verification activities based on relevant standard (ECSS Verification [4]), plus specific analytical, testing and inspection features. The analysis methodology takes into account the specific behaviour of ceramic materials, especially the statistical distribution of failures (Weibull) and the method to transfer it from elementary data to a full-scale structure. The demonstration of the efficiency of this method is described in a dedicated article [8]. The verification is completed by classical full-scale testing activities. Indications about proof testing, case of use and implementation are given and specific inspection and protection measures are described. These additional activities are necessary to ensure the required reliability. The aim of the guideline is to describe how to reach the same reliability level as for structures made of more classical materials (metals, composites).

  19. Advanced Test Reactor Safety Basis Upgrade Lessons Learned Relative to Design Basis Verification and Safety Basis Management

    International Nuclear Information System (INIS)

    G. L. Sharp; R. T. McCracken

    2004-01-01

    The Advanced Test Reactor (ATR) is a pressurized light-water reactor with a design thermal power of 250 MW. The principal function of the ATR is to provide a high neutron flux for testing reactor fuels and other materials. The reactor also provides other irradiation services such as radioisotope production. The ATR and its support facilities are located at the Test Reactor Area of the Idaho National Engineering and Environmental Laboratory (INEEL). An audit conducted by the Department of Energy's Office of Independent Oversight and Performance Assurance (DOE OA) raised concerns that design conditions at the ATR were not adequately analyzed in the safety analysis and that legacy design basis management practices had the potential to further impact safe operation of the facility.1 The concerns identified by the audit team, and issues raised during additional reviews performed by ATR safety analysts, were evaluated through the unreviewed safety question process resulting in shutdown of the ATR for more than three months while these concerns were resolved. Past management of the ATR safety basis, relative to facility design basis management and change control, led to concerns that discrepancies in the safety basis may have developed. Although not required by DOE orders or regulations, not performing design basis verification in conjunction with development of the 10 CFR 830 Subpart B upgraded safety basis allowed these potential weaknesses to be carried forward. Configuration management and a clear definition of the existing facility design basis have a direct relation to developing and maintaining a high quality safety basis which properly identifies and mitigates all hazards and postulated accident conditions. These relations and the impact of past safety basis management practices have been reviewed in order to identify lessons learned from the safety basis upgrade process and appropriate actions to resolve possible concerns with respect to the current ATR safety

  20. NEUTRON ALGORITHM VERIFICATION TESTING

    International Nuclear Information System (INIS)

    COWGILL, M.; MOSBY, W.; ARGONNE NATIONAL LABORATORY-WEST

    2000-01-01

    Active well coincidence counter assays have been performed on uranium metal highly enriched in 235 U. The data obtained in the present program, together with highly enriched uranium (HEU) metal data obtained in other programs, have been analyzed using two approaches, the standard approach and an alternative approach developed at BNL. Analysis of the data with the standard approach revealed that the form of the relationship between the measured reals and the 235 U mass varied, being sometimes linear and sometimes a second-order polynomial. In contrast, application of the BNL algorithm, which takes into consideration the totals, consistently yielded linear relationships between the totals-corrected reals and the 235 U mass. The constants in these linear relationships varied with geometric configuration and level of enrichment. This indicates that, when the BNL algorithm is used, calibration curves can be established with fewer data points and with more certainty than if a standard algorithm is used. However, this potential advantage has only been established for assays of HEU metal. In addition, the method is sensitive to the stability of natural background in the measurement facility

  1. Do people embrace praise even when they feel unworthy? A review of critical tests of self-enhancement versus self-verification.

    Science.gov (United States)

    Kwang, Tracy; Swann, William B

    2010-08-01

    Some contemporary theorists contend that the desire for self-enhancement is prepotent and more powerful than rival motives such as self-verification. If so, then even people with negative self-views will embrace positive evaluations. The authors tested this proposition by conducting a meta-analytic review of the relevant literature. The data provided ample evidence of self-enhancement strivings but little evidence of its prepotency. Instead, the evidence suggested that both motives are influential but control different response classes. In addition, other motives may sometimes come into play. For example, when rejection risk is high, people seem to abandon self-verification strivings, apparently in an effort to gratify their desire for communion. However, when rejection risk is low, as is the case in many secure marital relationships, people prefer self-verifying evaluations. The authors conclude that future researchers should broaden the bandwidth of their explanatory frameworks to include motives other than self-enhancement.

  2. Pile Model Tests Using Strain Gauge Technology

    Science.gov (United States)

    Krasiński, Adam; Kusio, Tomasz

    2015-09-01

    Ordinary pile bearing capacity tests are usually carried out to determine the relationship between load and displacement of pile head. The measurement system required in such tests consists of force transducer and three or four displacement gauges. The whole system is installed at the pile head above the ground level. This approach, however, does not give us complete information about the pile-soil interaction. We can only determine the total bearing capacity of the pile, without the knowledge of its distribution into the shaft and base resistances. Much more information can be obtained by carrying out a test of instrumented pile equipped with a system for measuring the distribution of axial force along its core. In the case of pile model tests the use of such measurement is difficult due to small scale of the model. To find a suitable solution for axial force measurement, which could be applied to small scale model piles, we had to take into account the following requirements: - a linear and stable relationship between measured and physical values, - the force measurement accuracy of about 0.1 kN, - the range of measured forces up to 30 kN, - resistance of measuring gauges against aggressive counteraction of concrete mortar and against moisture, - insensitivity to pile bending, - economical factor. These requirements can be fulfilled by strain gauge sensors if an appropriate methodology is used for test preparation (Hoffmann [1]). In this paper, we focus on some aspects of the application of strain gauge sensors for model pile tests. The efficiency of the method is proved on the examples of static load tests carried out on SDP model piles acting as single piles and in a group.

  3. Technology diffusion and diagnostic testing for prostate cancer

    Science.gov (United States)

    Schroeck, Florian R.; Kaufman, Samuel R.; Jacobs, Bruce L.; Skolarus, Ted A.; Miller, David C.; Weizer, Alon Z.; Montgomery, Jeffrey S.; Wei, John T.; Shahinian, Vahakn B.; Hollenbeck, Brent K.

    2013-01-01

    Purpose While the dissemination of robotic prostatectomy and intensity-modulated radiotherapy (IMRT) may fuel increased use of prostatectomy and radiotherapy, these new technologies may also have spillover effects related to diagnostic testing for prostate cancer. Therefore, we examined the association of regional technology penetration with receipt of prostate specific antigen (PSA) testing and prostate biopsy. Methods In this retrospective cohort study, we included 117,857 men age 66 and older from the 5% sample of Medicare beneficiaries living in the Surveillance Epidemiology and End Results (SEER) areas from 2003 – 2007. Regional technology penetration was measured as the number of providers performing robotic prostatectomy or IMRT per population in a healthcare market (i.e., hospital referral region). We assessed the association of technology penetration with rates of PSA testing and prostate biopsy with generalized estimating equations. Results High technology penetration was associated with increased rates of PSA testing (442 versus 425 per 1,000 person-years, pimpact of technology penetration on PSA testing and prostate biopsy was much smaller than the effect of age, race, and comorbidity (e.g., PSA testing rate per 1,000 person-years: 485 versus 373 for men with only one versus 3+ co-morbid conditions, ppenetration was associated with slightly higher rates of PSA testing and no change in prostate biopsy rates. Collectively, our findings temper concerns that adoption of new technology accelerates diagnostic testing for prostate cancer. PMID:23669564

  4. Environmental Technology Verification Report: Pesticide spray drift reduction technologies--Evaluation of the verification protocol for low and high speed wind tunnel testing

    Science.gov (United States)

    Pesticide spray drift is defined as the movement of spray droplets through the air at the time of application or soon thereafter from the target site to any non- or off-target site, excluding pesticide movements by erosion, migration, volatility, or windblown soil particles after...

  5. Demonstration and Field Test of airjacket technology

    Energy Technology Data Exchange (ETDEWEB)

    Faulkner, D.; Fisk, W.J.; Gadgil, A.J.; Sullivan, D.P.

    1998-06-01

    There are approximately 600,000 paint spray workers in the United States applying paints and coatings with some type of sprayer. Approximately 5% of these spray workers are in the South Coast Air Quality Management District (SCAQMD). These spray workers apply paints or other coatings to products such as bridges, houses, automobiles, wood and metal furniture, and other consumer and industrial products. The materials being sprayed include exterior and interior paints, lacquers, primers, shellacs, stains and varnishes. Our experimental findings indicate that the Airjacket does not significantly reduce the exposure of spray workers to paint fumes during HVLP spraying. The difference between ideal and actual spray paint procedures influence the mechanisms driving spray workers exposures to paint fumes and influence the viability of the Airjacket technology. In the ideal procedure, for which the Airjacket was conceived, the spray worker's exposure to paint fumes is due largely to the formation of a recirculating eddy between the spray worker and the object painted. The Airjacket ejects air to diminish and ventilate this eddy. In actual practice, exposures may result largely from directing paint upstream and from the bounce-back of the air/paint jet of the object being painted. The Airjacket, would not be expected to dramatically reduce exposures to paint fumes when the paint is not directed downstream or when the bounce-back of paint on the object creates a cloud of paint aerosols around the spray worker.

  6. Field test of short-notice random inspections for inventory-change verification at a low-enriched-uranium fuel-fabrication plant

    International Nuclear Information System (INIS)

    Fishbone, L.G.; Moussalli, G.; Naegele, G.

    1995-01-01

    An approach of short-notice random inspections (SNRIs) for inventory-change verification can enhance the effectiveness and efficiency of international safeguards at natural or low-enriched uranium (LEU) fuel fabrication plants. According to this approach, the plant operator declares the contents of nuclear material items before knowing if an inspection will occur to verify them. Additionally, items about which declarations are newly made should remain available for verification for an agreed time. Then a statistical inference can be made from verification results for items verified during SNRIs to the entire populations, i.e. the entire strata, even if inspectors were not present when many items were received or produced. A six-month field test of the feasibility of such SNRIs took place at the Westinghouse Electric Corporation Commercial Nuclear Fuel Division during 1993. Westinghouse personnel made daily declarations about both feed and product items, uranium hexafluoride cylinders and finished fuel assemblies, using a custom-designed computer ''mailbox''. Safeguards inspectors from the IAEA conducted eight SNRIs to verify these declarations. They arrived unannounced at the plant, in most cases immediately after travel from Canada, where the IAEA maintains a regional office. Items from both strata were verified during the SNRIs by meant of nondestructive assay equipment

  7. The Savannah River environmental technology field test platform: Phase II

    International Nuclear Information System (INIS)

    Rossabi, J.; Riha, B.D.; May, C.P.; Pemberton, B.E.; Jarosch, T.R.; Eddy-Dilek, C.A.; Looney, B.B.; Raymond, R.

    1995-01-01

    The principal goal in the development of new technologies for environmental monitoring and characterization is transferring them to organizations and individuals for use in site assessment and compliance monitoring. The DOE complex has devised several strategies to facilitate this transfer including joint research projects between private industries and government laboratories or universities (CRADAs), and streamlined licensing procedures. One strategy that has been under-utilized is a planned sequence gradually moving from laboratory development and field demonstration to long term evaluation and onsite use. Industrial partnership and commercial production can be initiated at any step based on the performance, market, user needs, and costs associated with the technology. The Savannah River Technology Center (SRTC) has been developing a program to rigorously field test promising environmental technologies that have not undergone EPA equivalency testing. The infrastructure and staff expertise developed as part of the activities of the Savannah River Integrated Demonstration Program (i.e., wells, available power, conventional baseline characterization and monitoring equipment, shelter structures) allows field testing of technologies without the difficulties of providing remote field support. By providing a well-characterized site and a well-developed infrastructure, technologies can be tested for long periods of time to determine their appropriate applications in environmental characterization and monitoring activities. Situation specific evaluations of the technology following stringent test plans can be made in comparison with simultaneous baseline methods and historical data. This program is designed to help expedite regulatory approval and technology transfer to manufacturers and the user community

  8. New and emerging technologies for genetic toxicity testing.

    Science.gov (United States)

    Lynch, Anthony M; Sasaki, Jennifer C; Elespuru, Rosalie; Jacobson-Kram, David; Thybaud, Véronique; De Boeck, Marlies; Aardema, Marilyn J; Aubrecht, Jiri; Benz, R Daniel; Dertinger, Stephen D; Douglas, George R; White, Paul A; Escobar, Patricia A; Fornace, Albert; Honma, Masamitsu; Naven, Russell T; Rusling, James F; Schiestl, Robert H; Walmsley, Richard M; Yamamura, Eiji; van Benthem, Jan; Kim, James H

    2011-04-01

    The International Life Sciences Institute (ILSI) Health and Environmental Sciences Institute (HESI) Project Committee on the Relevance and Follow-up of Positive Results in In Vitro Genetic Toxicity (IVGT) Testing established an Emerging Technologies and New Strategies Workgroup to review the current State of the Art in genetic toxicology testing. The aim of the workgroup was to identify promising technologies that will improve genotoxicity testing and assessment of in vivo hazard and risk, and that have the potential to help meet the objectives of the IVGT. As part of this initiative, HESI convened a workshop in Washington, DC in May 2008 to discuss mature, maturing, and emerging technologies in genetic toxicology. This article collates the abstracts of the New and Emerging Technologies Workshop together with some additional technologies subsequently considered by the workgroup. Each abstract (available in the online version of the article) includes a section addressed specifically to the strengths, weaknesses, opportunities, and threats associated with the respective technology. Importantly, an overview of the technologies and an indication of how their use might be aligned with the objectives of IVGT are presented. In particular, consideration was given with regard to follow-up testing of positive results in the standard IVGT tests (i.e., Salmonella Ames test, chromosome aberration assay, and mouse lymphoma assay) to add weight of evidence and/or provide mechanism of action for improved genetic toxicity risk assessments in humans. Copyright © 2010 Wiley-Liss, Inc.

  9. A 1:8.7 Scale Water Tunnel Verification & Validation Test of an Axial Flow Water Turbine

    Energy Technology Data Exchange (ETDEWEB)

    Fontaine, Arnold A. [Pennsylvania State Univ., University Park, PA (United States); Straka, William A. [Pennsylvania State Univ., University Park, PA (United States); Meyer, Richard S. [Pennsylvania State Univ., University Park, PA (United States); Jonson, Michael L. [Pennsylvania State Univ., University Park, PA (United States)

    2014-09-01

    As interest in waterpower technologies has increased over the last few years, there has been a growing need for a public database of measured data for these devices. This would provide a basic understanding of the technology and means to validate analytic and numerical models. Through collaboration between Sandia National Laboratories, Penn State University Applied Research Laboratory, and University of California, Davis, a new marine hydrokinetic turbine rotor was designed, fabricated at 1:8.7-scale, and experimentally tested to provide an open platform and dataset for further study and development. The water tunnel test of this three-bladed, horizontal-axis rotor recorded power production, blade loading, near-wake characterization, cavitation effects, and noise generation. This report documents the small-scale model test in detail and provides a brief discussion of the rotor design and an initial look at the results with comparison against low-order modeling tools. Detailed geometry and experimental measurements are released to Sandia National Laboratories as a data report addendum.

  10. Testing for Nuclear Thermal Propulsion Systems: Identification of Technologies for Effluent Treatment in Test Facilities

    Data.gov (United States)

    National Aeronautics and Space Administration — Key steps to ensure identification of relevant effluent treatment technologies for Nuclear Thermal Propulsion (NTP) testing include the following. 1. Review of...

  11. Review of Artificial Abrasion Test Methods for PV Module Technology

    Energy Technology Data Exchange (ETDEWEB)

    Miller, David C. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Muller, Matt T. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Simpson, Lin J. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-08-01

    This review is intended to identify the method or methods--and the basic details of those methods--that might be used to develop an artificial abrasion test. Methods used in the PV literature were compared with their closest implementation in existing standards. Also, meetings of the International PV Quality Assurance Task Force Task Group 12-3 (TG12-3, which is concerned with coated glass) were used to identify established test methods. Feedback from the group, which included many of the authors from the PV literature, included insights not explored within the literature itself. The combined experience and examples from the literature are intended to provide an assessment of the present industry practices and an informed path forward. Recommendations toward artificial abrasion test methods are then identified based on the experiences in the literature and feedback from the PV community. The review here is strictly focused on abrasion. Assessment methods, including optical performance (e.g., transmittance or reflectance), surface energy, and verification of chemical composition were not examined. Methods of artificially soiling PV modules or other specimens were not examined. The weathering of artificial or naturally soiled specimens (which may ultimately include combined temperature and humidity, thermal cycling and ultraviolet light) were also not examined. A sense of the purpose or application of an abrasion test method within the PV industry should, however, be evident from the literature.

  12. Understanding Student Teachers' Behavioural Intention to Use Technology: Technology Acceptance Model (TAM) Validation and Testing

    Science.gov (United States)

    Wong, Kung-Teck; Osman, Rosma bt; Goh, Pauline Swee Choo; Rahmat, Mohd Khairezan

    2013-01-01

    This study sets out to validate and test the Technology Acceptance Model (TAM) in the context of Malaysian student teachers' integration of their technology in teaching and learning. To establish factorial validity, data collected from 302 respondents were tested against the TAM using confirmatory factor analysis (CFA), and structural equation…

  13. Sharing Year 2000 Testing Information on DOD Information Technology Systems

    National Research Council Canada - National Science Library

    1998-01-01

    The audit objective was to determine whether planning for year 2000 testing is adequate to ensure that mission critical DoD information technology systems will continue to operate properly after the year 2000...

  14. Experimental inventory verification system

    International Nuclear Information System (INIS)

    Steverson, C.A.; Angerman, M.I.

    1991-01-01

    As Low As Reasonably Achievable (ALARA) goals and Department of Energy (DOE) inventory requirements are frequently in conflict at facilities across the DOE complex. The authors wish, on one hand, to verify the presence of correct amounts of nuclear materials that are in storage or in process; yet on the other hand, we wish to achieve ALARA goals by keeping individual and collective exposures as low as social, technical, economic, practical, and public policy considerations permit. The Experimental Inventory Verification System (EIVSystem) is a computer-based, camera-driven system that utilizes image processing technology to detect change in vault areas. Currently in the test and evaluation phase at Idaho National Engineering Laboratory, this system guards personnel. The EIVSystem continually monitors the vault, providing proof of changed status for objects sorted within the vault. This paper reports that these data could provide the basis for reducing inventory requirements when no change has occurred, thus helping implement ALARA policy; the data will also help describe there target area of an inventory when change has been shown to occur

  15. CTBT integrated verification system evaluation model supplement

    Energy Technology Data Exchange (ETDEWEB)

    EDENBURN,MICHAEL W.; BUNTING,MARCUS; PAYNE JR.,ARTHUR C.; TROST,LAWRENCE C.

    2000-03-02

    Sandia National Laboratories has developed a computer based model called IVSEM (Integrated Verification System Evaluation Model) to estimate the performance of a nuclear detonation monitoring system. The IVSEM project was initiated in June 1994, by Sandia's Monitoring Systems and Technology Center and has been funded by the U.S. Department of Energy's Office of Nonproliferation and National Security (DOE/NN). IVSEM is a simple, ''top-level,'' modeling tool which estimates the performance of a Comprehensive Nuclear Test Ban Treaty (CTBT) monitoring system and can help explore the impact of various sensor system concepts and technology advancements on CTBT monitoring. One of IVSEM's unique features is that it integrates results from the various CTBT sensor technologies (seismic, in sound, radionuclide, and hydroacoustic) and allows the user to investigate synergy among the technologies. Specifically, IVSEM estimates the detection effectiveness (probability of detection), location accuracy, and identification capability of the integrated system and of each technology subsystem individually. The model attempts to accurately estimate the monitoring system's performance at medium interfaces (air-land, air-water) and for some evasive testing methods such as seismic decoupling. The original IVSEM report, CTBT Integrated Verification System Evaluation Model, SAND97-25 18, described version 1.2 of IVSEM. This report describes the changes made to IVSEM version 1.2 and the addition of identification capability estimates that have been incorporated into IVSEM version 2.0.

  16. CTBT integrated verification system evaluation model supplement

    International Nuclear Information System (INIS)

    EDENBURN, MICHAEL W.; BUNTING, MARCUS; PAYNE, ARTHUR C. JR.; TROST, LAWRENCE C.

    2000-01-01

    Sandia National Laboratories has developed a computer based model called IVSEM (Integrated Verification System Evaluation Model) to estimate the performance of a nuclear detonation monitoring system. The IVSEM project was initiated in June 1994, by Sandia's Monitoring Systems and Technology Center and has been funded by the U.S. Department of Energy's Office of Nonproliferation and National Security (DOE/NN). IVSEM is a simple, ''top-level,'' modeling tool which estimates the performance of a Comprehensive Nuclear Test Ban Treaty (CTBT) monitoring system and can help explore the impact of various sensor system concepts and technology advancements on CTBT monitoring. One of IVSEM's unique features is that it integrates results from the various CTBT sensor technologies (seismic, in sound, radionuclide, and hydroacoustic) and allows the user to investigate synergy among the technologies. Specifically, IVSEM estimates the detection effectiveness (probability of detection), location accuracy, and identification capability of the integrated system and of each technology subsystem individually. The model attempts to accurately estimate the monitoring system's performance at medium interfaces (air-land, air-water) and for some evasive testing methods such as seismic decoupling. The original IVSEM report, CTBT Integrated Verification System Evaluation Model, SAND97-25 18, described version 1.2 of IVSEM. This report describes the changes made to IVSEM version 1.2 and the addition of identification capability estimates that have been incorporated into IVSEM version 2.0

  17. PTC test bed upgrades to provide ACSES testing support capabilities at transportation technology center.

    Science.gov (United States)

    2015-06-01

    FRA Task Order 314 upgraded the Positive Train Control (PTC) Test Bed at the Transportation Technology Center to support : testing of PTC systems, components, and related equipment associated with the Advanced Civil Speed Enforcement System : (ACSES)...

  18. HDL to verification logic translator

    Science.gov (United States)

    Gambles, J. W.; Windley, P. J.

    1992-01-01

    The increasingly higher number of transistors possible in VLSI circuits compounds the difficulty in insuring correct designs. As the number of possible test cases required to exhaustively simulate a circuit design explodes, a better method is required to confirm the absence of design faults. Formal verification methods provide a way to prove, using logic, that a circuit structure correctly implements its specification. Before verification is accepted by VLSI design engineers, the stand alone verification tools that are in use in the research community must be integrated with the CAD tools used by the designers. One problem facing the acceptance of formal verification into circuit design methodology is that the structural circuit descriptions used by the designers are not appropriate for verification work and those required for verification lack some of the features needed for design. We offer a solution to this dilemma: an automatic translation from the designers' HDL models into definitions for the higher-ordered logic (HOL) verification system. The translated definitions become the low level basis of circuit verification which in turn increases the designer's confidence in the correctness of higher level behavioral models.

  19. A survey on the high reliability software verification and validation technology for instrumentation and control in NPP.

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Kee Choon; Lee, Chang Soo; Dong, In Sook [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-01-01

    This document presents the technical status of the software verification and validation (V and V) efforts to support developing and licensing digital instrumentation and control (I and C) systems in nuclear power plants. We have reviewed codes and standards to be concensus criteria among vendor, licensee and licenser. Then we have described the software licensing procedures under 10 CFR 50 and 10 CFR 52 of the United States cope with the licensing barrier. At last, we have surveyed the technical issues related to developing and licensing the high integrity software for digital I and C systems. These technical issues let us know the development direction of our own software V and V methodology. (Author) 13 refs., 2 figs.,.

  20. Technology diffusion and diagnostic testing for prostate cancer.

    Science.gov (United States)

    Schroeck, Florian R; Kaufman, Samuel R; Jacobs, Bruce L; Skolarus, Ted A; Miller, David C; Weizer, Alon Z; Montgomery, Jeffrey S; Wei, John T; Shahinian, Vahakn B; Hollenbeck, Brent K

    2013-11-01

    While the dissemination of robotic prostatectomy and intensity modulated radiotherapy may fuel the increased use of prostatectomy and radiotherapy, these new technologies may also have spillover effects related to diagnostic testing for prostate cancer. Therefore, we examined the association of regional technology penetration with the receipt of prostate specific antigen testing and prostate biopsy. In this retrospective cohort study we included 117,857 men 66 years old or older from the 5% sample of Medicare beneficiaries living in Surveillance, Epidemiology and End Results (SEER) areas from 2003 to 2007. Regional technology penetration was measured as the number of providers performing robotic prostatectomy or intensity modulated radiotherapy per population in a health care market, ie hospital referral region. We assessed the association of technology penetration with the prostate specific antigen testing rate and prostate biopsy using generalized estimating equations. High technology penetration was associated with an increased rate of prostate specific antigen testing (442 vs 425/1,000 person-years, pimpact of technology penetration on prostate specific antigen testing and prostate biopsy was much less than the effect of age, race and comorbidity, eg the prostate specific antigen testing rate per 1,000 person-years was 485 vs 373 for men with only 1 vs 3+ comorbid conditions (ppenetration is associated with a slightly higher rate of prostate specific antigen testing and no change in the prostate biopsy rate. Collectively, our findings temper concerns that adopting new technology accelerates diagnostic testing for prostate cancer. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  1. Development of in-pile test and evaluation technology

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yung Hwan; Park, Jong Man; Joo, Kee Nam; Park, Duk Keun; Park, Se Jin; Oh, Jong Myung; Kim, Tae Ryong; Park Jin Suk; Lee, Jae Han [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-08-01

    To develop the in-pile test and evaluation technologies using KMRR, basic design of instrumented capsule and auxiliary system for material irradiation test and the related studies are performed. First, reactor and test hole characteristics are summarized, and conceptual design requirements of capsule to KMRR are reviewed. And fundamental principles and criteria for the instrumented capsule design are summarized. Basic design and analysis of instrumented capsule are performed, and design of capsule supporting system are also performed and structural integrity of the system is analyzed. Based on the prior studies, test mock-ups are designed and manufactured, and thermohydraulic and vibration tests are prepared. And, as in-pile test evaluation technologies, KMRR neutron dosimetry and mechanical tests related to material irradiation are investigated. 67 figs, 30 tabs, 41 refs. (Author).

  2. Systems Approach to Arms Control Verification

    Energy Technology Data Exchange (ETDEWEB)

    Allen, K; Neimeyer, I; Listner, C; Stein, G; Chen, C; Dreicer, M

    2015-05-15

    Using the decades of experience of developing concepts and technologies for verifying bilateral and multilateral arms control agreements, a broad conceptual systems approach is being developed that takes into account varying levels of information and risk. The IAEA has already demonstrated the applicability of a systems approach by implementing safeguards at the State level, with acquisition path analysis as the key element. In order to test whether such an approach could also be implemented for arms control verification, an exercise was conducted in November 2014 at the JRC ITU Ispra. Based on the scenario of a hypothetical treaty between two model nuclear weapons states aimed at capping their nuclear arsenals at existing levels, the goal of this exercise was to explore how to use acquisition path analysis in an arms control context. Our contribution will present the scenario, objectives and results of this exercise, and attempt to define future workshops aimed at further developing verification measures that will deter or detect treaty violations.

  3. ETV Tech Brief: Rapid Fungi and Bacteria Detection Technologies

    Science.gov (United States)

    Technical brief that summarizes the results for Mycometer, Inc. Mycometer®-test and Bactiquant®-test, which are rapid detection technologies for fungi and bacteria. The brief summarizes the results of the verification report and statement.

  4. On the safety and performance demonstration tests of Prototype Gen-IV Sodium-Cooled Fast Reactor and validation and verification of computational codes

    International Nuclear Information System (INIS)

    Kim, Jong Bum; Jeong, Ji Young; Lee, Tae Ho; Kim, Sung Kyun; Euh, Dong Jin; Joo, Hyung Kook

    2016-01-01

    The design of Prototype Gen-IV Sodium-Cooled Fast Reactor (PGSFR) has been developed and the validation and verification (V and V) activities to demonstrate the system performance and safety are in progress. In this paper, the current status of test activities is described briefly and significant results are discussed. The large-scale sodium thermal-hydraulic test program, Sodium Test Loop for Safety Simulation and Assessment-1 (STELLA-1), produced satisfactory results, which were used for the computer codes V and V, and the performance test results of the model pump in sodium showed good agreement with those in water. The second phase of the STELLA program with the integral effect tests facility, STELLA-2, is in the detailed design stage of the design process. The sodium thermal-hydraulic experiment loop for finned-tube sodium-to-air heat exchanger performance test, the intermediate heat exchanger test facility, and the test facility for the reactor flow distribution are underway. Flow characteristics test in subchannels of a wire-wrapped rod bundle has been carried out for safety analysis in the core and the dynamic characteristic test of upper internal structure has been performed for the seismic analysis model for the PGSFR. The performance tests for control rod assemblies (CRAs) have been conducted for control rod drive mechanism driving parts and drop tests of the CRA under scram condition were performed. Finally, three types of inspection sensors under development for the safe operation of the PGSFR were explained with significant results

  5. On the safety and performance demonstration tests of Prototype Gen-IV Sodium-Cooled Fast Reactor and validation and verification of computational codes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Bum; Jeong, Ji Young; Lee, Tae Ho; Kim, Sung Kyun; Euh, Dong Jin; Joo, Hyung Kook [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    The design of Prototype Gen-IV Sodium-Cooled Fast Reactor (PGSFR) has been developed and the validation and verification (V and V) activities to demonstrate the system performance and safety are in progress. In this paper, the current status of test activities is described briefly and significant results are discussed. The large-scale sodium thermal-hydraulic test program, Sodium Test Loop for Safety Simulation and Assessment-1 (STELLA-1), produced satisfactory results, which were used for the computer codes V and V, and the performance test results of the model pump in sodium showed good agreement with those in water. The second phase of the STELLA program with the integral effect tests facility, STELLA-2, is in the detailed design stage of the design process. The sodium thermal-hydraulic experiment loop for finned-tube sodium-to-air heat exchanger performance test, the intermediate heat exchanger test facility, and the test facility for the reactor flow distribution are underway. Flow characteristics test in subchannels of a wire-wrapped rod bundle has been carried out for safety analysis in the core and the dynamic characteristic test of upper internal structure has been performed for the seismic analysis model for the PGSFR. The performance tests for control rod assemblies (CRAs) have been conducted for control rod drive mechanism driving parts and drop tests of the CRA under scram condition were performed. Finally, three types of inspection sensors under development for the safe operation of the PGSFR were explained with significant results.

  6. The development of flow test technology for PWR fuel assembly

    International Nuclear Information System (INIS)

    Chung, Moon Ki; Cha, Chong Hee; Chung, Chang Hwan; Chun, Se Young; Song, Chul Hwa; Chung, Heung Joon; Won, Soon Yeun; Cho, Yeong Rho; Kim, Bok Deuk

    1988-05-01

    KAERI has an extensive program to develope PWR fuel assembly. In relation to the program, development of flow test technology is needed to evaluate the thermal hydraulic compactibility and mechanical integrity of domestically fabricated nuclear fuels. A high-pressure and high-temperature flow test facility was designed to test domestically fabricated fuel assembly. The test section of the facility has capacity of a 6x6 full length PWR fuel assembly. A flow test rig was designed and installed at Cold Test Loop to carry out model experiments with 5x5 rod assembly under atmosphere pressure to get information about the characteristics of pressure loss of spacer grids and velocity distribution in the subchannels. LDV measuring technology was established using TSI's Laser Dopper Velocimeter 9100-3 System

  7. NDE Technology Development Program for Non-Visual Volumetric Inspection Technology; Sensor Effectiveness Testing Report

    Energy Technology Data Exchange (ETDEWEB)

    Moran, Traci L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Larche, Michael R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Denslow, Kayte M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Glass, Samuel W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-08-31

    The Pacific Northwest National Laboratory (PNNL) located in Richland, Washington, hosted and administered Sensor Effectiveness Testing that allowed four different participants to demonstrate the NDE volumetric inspection technologies that were previously demonstrated during the Technology Screening session. This document provides a Sensor Effectiveness Testing report for the final part of Phase I of a three-phase NDE Technology Development Program designed to identify and mature a system or set of non-visual volumetric NDE technologies for Hanford DST primary liner bottom inspection. Phase I of the program will baseline the performance of current or emerging non-visual volumetric NDE technologies for their ability to detect and characterize primary liner bottom flaws, and identify candidate technologies for adaptation and maturation for Phase II of the program.

  8. Environmental Technology Verification Report. Field Portable Gas Chromatograph/Mass Spectrometer. Viking Instruments Corporation SpectraTrak (Trademark) 672

    National Research Council Canada - National Science Library

    Enfield, Wayne

    1997-01-01

    .... This self-contained, field transportable system, whose design has been adapted from laboratory technology, uses a contained, chromatographic column and accompanying mass spectrometer to provide...

  9. Is flow verification necessary

    International Nuclear Information System (INIS)

    Beetle, T.M.

    1986-01-01

    Safeguards test statistics are used in an attempt to detect diversion of special nuclear material. Under assumptions concerning possible manipulation (falsification) of safeguards accounting data, the effects on the statistics due to diversion and data manipulation are described algebraically. A comprehensive set of statistics that is capable of detecting any diversion of material is defined in terms of the algebraic properties of the effects. When the assumptions exclude collusion between persons in two material balance areas, then three sets of accounting statistics are shown to be comprehensive. Two of the sets contain widely known accountancy statistics. One of them does not require physical flow verification - comparisons of operator and inspector data for receipts and shipments. The third set contains a single statistic which does not require physical flow verification. In addition to not requiring technically difficult and expensive flow verification, this single statistic has several advantages over other comprehensive sets of statistics. This algebraic approach as an alternative to flow verification for safeguards accountancy is discussed in this paper

  10. FY 1981 report on the results of the verification test on the methanol conversion for oil-fired power plant. Verification test on the environmental safety; 1981 nendo sekiyu karyoku hatsudensho metanoru tenkan tou jissho shiken seika hokokusho. Kankyo anzensei jissho shiken

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1982-08-01

    Assuming the use of methanol which is expected to be promising as petroleum substituting fluid fuel, an investigational study was made on the environmental safety, and the FY 1981 results were summed up. In the study/evaluation of the verification test, conducted were the survey of the results of the studies having been made on toxicity of methanol, working-out of a plan for verification test on the environmental safety of methanol, etc. Moreover, for the purpose of grasping effects of methanol and methanol combustion gas on living organisms, the following were carried out: design and a part of the construction work of facilities in which the test is made for breeding monkey/aquatic animal in the methanol environment, test on its effect on aquatic animal, and purchase of a part of the equipment used for test on its effect on rat/mouse. As to the tests, the following were in the planning stage: toxicity test using macaca on high-concentration (acute)/low-concentration (chronic) inhalation of methanol gas, toxicity test on inhalation of formaldehyde as mock combustion flue gas, test on effects of methanol on fish/shellfish in terms of the fatal concentration/repellent behavior/chronic influence/hindrance of multiplication, etc. (NEDO)

  11. Field test of short-notice random inspections for inventory-change verification at a low-enriched-uranium fuel-fabrication plant: Preliminary summary

    International Nuclear Information System (INIS)

    Fishbone, L.G.; Moussalli, G.; Naegele, G.; Ikonomou, P.; Hosoya, M.; Scott, P.; Fager, J.; Sanders, C.; Colwell, D.; Joyner, C.J.

    1994-01-01

    An approach of short-notice random inspections (SNRIs) for inventory-change verification can enhance the effectiveness and efficiency of international safeguards at natural or low-enriched uranium (LEU) fuel fabrication plants. According to this approach, the plant operator declares the contents of nuclear material items before knowing if an inspection will occur to verify them. Additionally, items about which declarations are newly made should remain available for verification for an agreed time. This report details a six-month field test of the feasibility of such SNRIs which took place at the Westinghouse Electric Corporation Commercial Nuclear Fuel Division. Westinghouse personnel made daily declarations about both feed and product items, uranium hexafluoride cylinders and finished fuel assemblies, using a custom-designed computer ''mailbox''. Safeguards inspectors from the IAEA conducted eight SNRIs to verify these declarations. Items from both strata were verified during the SNRIs by means of nondestructive assay equipment. The field test demonstrated the feasibility and practicality of key elements of the SNRI approach for a large LEU fuel fabrication plant

  12. Hybrid microcircuit technology handbook materials, processes, design, testing and production

    CERN Document Server

    Licari, James J

    1998-01-01

    The Hybrid Microcircuit Technology Handbook integrates the many diverse technologies used in the design, fabrication, assembly, and testing of hybrid segments crucial to the success of producing reliable circuits in high yields. Among these are: resistor trimming, wire bonding, die attachment, cleaning, hermetic sealing, and moisture analysis. In addition to thin films, thick films, and assembly processes, important chapters on substrate selections, handling (including electrostatic discharge), failure analysis, and documentation are included. A comprehensive chapter of design guidelines will

  13. Partial Defect Verification of Spent Fuel Assemblies by PDET: Principle and Field Testing in Interim Spent Fuel Storage Facility (CLAB) in Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Ham, Y.S.; Kerr, P.; Sitaraman, S.; Swan, R. [Global Security Directorate, Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Rossa, R. [SCK-CEN, Mol (Belgium); Liljenfeldt, H. [SKB in Oskarshamn (Sweden)

    2015-07-01

    The need for the development of a credible method and instrument for partial defect verification of spent fuel has been emphasized over a few decades in the safeguards communities as the diverted spent fuel pins can be the source of nuclear terrorism or devices. The need is increasingly more important and even urgent as many countries have started to transfer spent fuel to so called 'difficult-to-access' areas such as dry storage casks, reprocessing or geological repositories. Partial defect verification is required by IAEA before spent fuel is placed into 'difficult-to-access' areas. Earlier, Lawrence Livermore National Laboratory (LLNL) has reported the successful development of a new, credible partial defect verification method for pressurized water reactor (PWR) spent fuel assemblies without use of operator data, and further reported the validation experiments using commercial spent fuel assemblies with some missing fuel pins. The method was found to be robust as the method is relatively invariant to the characteristic variations of spent fuel assemblies such as initial fuel enrichment, cooling time, and burn-up. Since then, the PDET system has been designed and prototyped for 17x17 PWR spent fuel assemblies, complete with data acquisition software and acquisition electronics. In this paper, a summary description of the PDET development followed by results of the first successful field testing using the integrated PDET system and actual spent fuel assemblies performed in a commercial spent fuel storage site, known as Central Interim Spent fuel Storage Facility (CLAB) in Sweden will be presented. In addition to partial defect detection initial studies have determined that the tool can be used to verify the operator declared average burnup of the assembly as well as intra-assembly burnup levels. (authors)

  14. Development of modelling algorithm of technological systems by statistical tests

    Science.gov (United States)

    Shemshura, E. A.; Otrokov, A. V.; Chernyh, V. G.

    2018-03-01

    The paper tackles the problem of economic assessment of design efficiency regarding various technological systems at the stage of their operation. The modelling algorithm of a technological system was performed using statistical tests and with account of the reliability index allows estimating the level of machinery technical excellence and defining the efficiency of design reliability against its performance. Economic feasibility of its application shall be determined on the basis of service quality of a technological system with further forecasting of volumes and the range of spare parts supply.

  15. Honeycomb technology materials, design, manufacturing, applications and testing

    CERN Document Server

    Bitzer, Tom

    1997-01-01

    Honeycomb Technology is a guide to honeycomb cores and honeycomb sandwich panels, from the manufacturing methods by which they are produced, to the different types of design, applications for usage and methods of testing the materials. It explains the different types of honeycomb cores available and provides tabulated data of their properties. The author has been involved in the testing and design of honeycomb cores and sandwich panels for nearly 30 years. Honeycomb Technology reflects this by emphasizing a `hands-on' approach and discusses procedures for designing sandwich panels, explaining the necessary equations. Also included is a section on how to design honeycomb energy absorbers and one full chapter discussing honeycomb core and sandwich panel testing. Honeycomb Technology will be of interest to engineers in the aircraft, aerospace and building industries. It will also be of great use to engineering students interested in basic sandwich panel design.

  16. Development of non-destructive testing (NDT) technology in Pakistan

    International Nuclear Information System (INIS)

    Khan, A.A.

    2005-01-01

    Non-Destructive Testing (NDT) techniques are being extensively used to improve and maintain the quality of manufactured goods as well as for proper maintenance of industrial plants and equipment. Typical industries that benefit most include Aerospace, Chemical, Heavy Mechanical Fabrication, Conventional and Nuclear Power Generation, Automobiles, Oil and Gas, Shipbuilding, Foundries, and Armaments, etc. As the name implies, with these techniques an industrial product is inspected mostly for defects in its structure without destroying it. Among the most widely used NDT techniques for the detection of internal defects are Radiographic and Ultrasonic Testing. For surface and just below the surface defects Magnetic Particle Testing, Penetrant Testing and Eddy Current Testing are commonly used. In addition to these, there are some NDT methods which have specific applications. These include Acoustic Emission, Thermal and Infrared Testing, Microwave Testing, Computer Tomography, Strain Gauging, Leak Testing and Holography, etc. This paper describes various phases through which the development of NDT technology passed and its present state of the art. It started with the undertaking of a nuclear technology programme and has matured along with it. As it stands we are fully competent to undertake various essential activities related to this technology, namely, (I) raining and certification of NDT personnel at various levels. (II) revision of NDT services to various industrial sectors including nuclear power during manufacture, fabrication, pre-service inspection (PSI) and in-service inspection (ISI). (author)

  17. New technologies in electromagnetic non-destructive testing

    CERN Document Server

    Huang, Songling

    2016-01-01

    This book introduces novel developments in the field of electromagnetic non-destructive testing and evaluation (NDT/E). The topics include electromagnetic ultrasonic guided wave testing, pulsed eddy current testing, remote field eddy current testing, low frequency eddy current testing, metal magnetic memory testing, and magnetic flux leakage testing. Considering the increasing concern about the safety maintenance of critical structures in various industries and everyday life, these topics presented here will be of particular interest to the readers in the NDT/E field. This book covers both theoretical researches and the engineering applications of the electromagnetic NDT technology. It could serve as a valuable reference for college students and relevant NDT technicians. It is also a useful material for qualification training and higher learning for nondestructive testing professionals.

  18. NASA funding opportunities for optical fabrication and testing technology development

    Science.gov (United States)

    Stahl, H. Philip

    2013-09-01

    NASA requires technologies to fabricate and test optical components to accomplish its highest priority science missions. The NRC ASTRO2010 Decadal Survey states that an advanced large-aperture UVOIR telescope is required to enable the next generation of compelling astrophysics and exo-planet science; and, that present technology is not mature enough to affordably build and launch any potential UVOIR mission concept. The NRC 2012 NASA Space Technology Roadmaps and Priorities Report states that the highest priority technology in which NASA should invest to `Expand our understanding of Earth and the universe' is next generation X-ray and UVOIR telescopes. Each of the Astrophysics division Program Office Annual Technology Reports (PATR) identifies specific technology needs. NASA has a variety of programs to fund enabling technology development: SBIR (Small Business Innovative Research); the ROSES APRA and SAT programs (Research Opportunities in Space and Earth Science; Astrophysics Research and Analysis program; Strategic Astrophysics Technology program); and several Office of the Chief Technologist (OCT) programs.

  19. Real-Time Electronic Tracking of Diarrheal Episodes and Laxative Therapy Enables Verification of Clostridium difficile Clinical Testing Criteria and Reduction of Clostridium difficile Infection Rates.

    Science.gov (United States)

    Truong, Cynthia Y; Gombar, Saurabh; Wilson, Richard; Sundararajan, Gopalakrishnan; Tekic, Natasa; Holubar, Marisa; Shepard, John; Madison, Alexandra; Tompkins, Lucy; Shah, Neil; Deresinski, Stan; Schroeder, Lee F; Banaei, Niaz

    2017-05-01

    Health care-onset health care facility-associated Clostridium difficile infection (HO-CDI) is overdiagnosed for several reasons, including the high prevalence of C. difficile colonization and the inability of hospitals to limit testing to patients with clinically significant diarrhea. We conducted a quasiexperimental study from 22 June 2015 to 30 June 2016 on consecutive inpatients with C. difficile test orders at an academic hospital. Real-time electronic patient data tracking was used by the laboratory to enforce testing criteria (defined as the presence of diarrhea [≥3 unformed stools in 24 h] and absence of laxative intake in the prior 48 h). Outcome measures included C. difficile test utilization, HO-CDI incidence, oral vancomycin utilization, and clinical complications. During the intervention, 7.1% (164) and 9.1% (211) of 2,321 C. difficile test orders were canceled due to absence of diarrhea and receipt of laxative therapy, respectively. C. difficile test utilization decreased upon implementation from an average of 208.8 tests to 143.0 tests per 10,000 patient-days ( P difficile results. Real-time electronic clinical data tracking is an effective tool for verification of C. difficile clinical testing criteria and safe reduction of inflated HO-CDI rates. Copyright © 2017 American Society for Microbiology.

  20. Selected Test Results from the Encell Technology Nickel Iron Battery

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Summer Kamal Rhodes [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Power Sources R& D; Baca, Wes Edmund [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Power Sources R& D; Avedikian, Kristan [Encell Technology, Alachua, FL (United States)

    2014-09-01

    The performance of the Encell Nickel Iron (NiFe) battery was measured. Tests included capacity, capacity as a function of rate, capacity as a function of temperature, charge retention (28-day), efficiency, accelerated life projection, and water refill evaluation. The goal of this work was to evaluate the general performance of the Encell NiFe battery technology for stationary applications and demonstrate the chemistry's capabilities in extreme conditions. Test results have indicated that the Encell NiFe battery technology can provide power levels up to the 6C discharge rate, ampere-hour efficiency above 70%. In summary, the Encell batteries have met performance metrics established by the manufacturer. Long-term cycle tests are not included in this report. A cycle test at elevated temperature was run, funded by the manufacturer, which Encell uses to predict long-term cycling performance, and which passed their prescribed metrics.

  1. Replacement of Hydrochlorofluorocarbon (HCFC) -225 Solvent for Cleaning and Verification Sampling of NASA Propulsion Oxygen Systems Hardware, Ground Support Equipment, and Associated Test Systems

    Science.gov (United States)

    Mitchell, Mark A.; Lowrey, Nikki M.

    2015-01-01

    Since the 1990's, when the Class I Ozone Depleting Substance (ODS) chlorofluorocarbon-113 (CFC-113) was banned, NASA's rocket propulsion test facilities at Marshall Space Flight Center (MSFC) and Stennis Space Center (SSC) have relied upon hydrochlorofluorocarbon-225 (HCFC-225) to safely clean and verify the cleanliness of large scale propulsion oxygen systems. Effective January 1, 2015, the production, import, export, and new use of HCFC-225, a Class II ODS, was prohibited by the Clean Air Act. In 2012 through 2014, leveraging resources from both the NASA Rocket Propulsion Test Program and the Defense Logistics Agency - Aviation Hazardous Minimization and Green Products Branch, test labs at MSFC, SSC, and Johnson Space Center's White Sands Test Facility (WSTF) collaborated to seek out, test, and qualify a replacement for HCFC-225 that is both an effective cleaner and safe for use with oxygen systems. Candidate solvents were selected and a test plan was developed following the guidelines of ASTM G127, Standard Guide for the Selection of Cleaning Agents for Oxygen Systems. Solvents were evaluated for materials compatibility, oxygen compatibility, cleaning effectiveness, and suitability for use in cleanliness verification and field cleaning operations. Two solvents were determined to be acceptable for cleaning oxygen systems and one was chosen for implementation at NASA's rocket propulsion test facilities. The test program and results are summarized. This project also demonstrated the benefits of cross-agency collaboration in a time of limited resources.

  2. Semantic test of a technology management model in family business

    Directory of Open Access Journals (Sweden)

    Guillermo Jesús Larios

    2017-10-01

    Full Text Available This paper assembles family business conceptions from the innovation and technology management perspective, and tests them in the case of a Mexican sugarcane producer. Literature indicates that non-financial objectives, risk aversion and strong controls negatively influence family firms’ innovation outcomes. Based on semantic network analysis, we collected transversal information on the firm’s technology activities, innovation values and organizational flows, which allowed for the identification of an organizational management profile that shapes an innovation style. Although we acknowledge literature consistency in aspects such as family direct influence and control, or the importance of STI partnerships and external knowledge, our findings didn’t identify any concerns about losing control in parts of the family business. This research contributes to the understanding of technology management and organizational elements in an emerging economy’s family firm from a relational perspective. Implications for theory endorsement and characterization of family business innovation and technology management in developing countries are discussed.

  3. Utility advanced turbine systems (ATS) technology readiness testing

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-09-15

    The overall objective of the Advanced Turbine System (ATS) Phase 3 Cooperative Agreement between GE and the US Department of Energy (DOE) is the development of a highly efficient, environmentally superior, and cost-competitive utility ATS for base-load utility-scale power generation, the GE 7H (60 Hz) combined cycle power system, and related 9H (50 Hz) common technology. The major effort will be expended on detail design. Validation of critical components and technologies will be performed, including: hot gas path component testing, sub-scale compressor testing, steam purity test trials, and rotational heat transfer confirmation testing. Processes will be developed to support the manufacture of the first system, which was to have been sited and operated in Phase 4 but will now be sited and operated commercially by GE. This change has resulted from DOE's request to GE for deletion of Phase 4 in favor of a restructured Phase 3 (as Phase 3R) to include full speed, no load (FSNL) testing of the 7H gas turbine. Technology enhancements that are not required for the first machine design but will be critical for future ATS advances in performance, reliability, and costs will be initiated. Long-term tests of materials to confirm design life predictions will continue. A schematic of the GE H machine is shown.

  4. RF and microwave integrated circuit development technology, packaging and testing

    CERN Document Server

    Gamand, Patrice; Kelma, Christophe

    2018-01-01

    RF and Microwave Integrated Circuit Development bridges the gap between existing literature, which focus mainly on the 'front-end' part of a product development (system, architecture, design techniques), by providing the reader with an insight into the 'back-end' part of product development. In addition, the authors provide practical answers and solutions regarding the choice of technology, the packaging solutions and the effects on the performance on the circuit and to the industrial testing strategy. It will also discuss future trends and challenges and includes case studies to illustrate examples. * Offers an overview of the challenges in RF/microwave product design * Provides practical answers to packaging issues and evaluates its effect on the performance of the circuit * Includes industrial testing strategies * Examines relevant RF MIC technologies and the factors which affect the choice of technology for a particular application, e.g. technical performance and cost * Discusses future trends and challen...

  5. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Performance Verification Reports: Final Comprehensive Performance Test Report, P/N: 1356006-1, S.N: 202/A2

    Science.gov (United States)

    Platt, R.

    1998-01-01

    This is the Performance Verification Report. the process specification establishes the requirements for the comprehensive performance test (CPT) and limited performance test (LPT) of the earth observing system advanced microwave sounding unit-A2 (EOS/AMSU-A2), referred to as the unit. The unit is defined on drawing 1356006.

  6. Methods of Software Verification

    Directory of Open Access Journals (Sweden)

    R. E. Gurin

    2015-01-01

    Full Text Available This article is devoted to the problem of software verification (SW. Methods of software verification designed to check the software for compliance with the stated requirements such as correctness, system security and system adaptability to small changes in the environment, portability and compatibility, etc. These are various methods both by the operation process and by the way of achieving result. The article describes the static and dynamic methods of software verification and paid attention to the method of symbolic execution. In its review of static analysis are discussed and described the deductive method, and methods for testing the model. A relevant issue of the pros and cons of a particular method is emphasized. The article considers classification of test techniques for each method. In this paper we present and analyze the characteristics and mechanisms of the static analysis of dependencies, as well as their views, which can reduce the number of false positives in situations where the current state of the program combines two or more states obtained both in different paths of execution and in working with multiple object values. Dependences connect various types of software objects: single variables, the elements of composite variables (structure fields, array elements, the size of the heap areas, the length of lines, the number of initialized array elements in the verification code using static methods. The article pays attention to the identification of dependencies within the framework of the abstract interpretation, as well as gives an overview and analysis of the inference tools.Methods of dynamic analysis such as testing, monitoring and profiling are presented and analyzed. Also some kinds of tools are considered which can be applied to the software when using the methods of dynamic analysis. Based on the work a conclusion is drawn, which describes the most relevant problems of analysis techniques, methods of their solutions and

  7. 2009 Continued Testing of the Orion Atmosphere Revitalization Technology

    Science.gov (United States)

    Button, Amy B.; Swerterlitsch, Jeffrey J.

    2010-01-01

    An amine-based carbon dioxide (CO2) and water vapor sorbent in pressure-swing regenerable beds has been developed by Hamilton Sundstrand and baselined for the Orion Atmosphere Revitalization System (ARS). In three previous years at this conference, reports were presented on extensive Johnson Space Center (JSC) testing of this technology in a sea-level pressure environment, with simulated and real human metabolic loads, in both open and closed-loop configurations. The test article design was iterated a third time before the latest series of such tests, which was performed in the first half of 2009. The new design incorporates a canister configuration modification for overall unit compactness and reduced pressure drop, as well as a new process flow control valve that incorporates both compressed gas purge and dual-end vacuum desorption capabilities. This newest test article is very similar to the flight article designs. Baseline tests of the new unit were performed to compare its performance to that of the previous test articles. Testing of compressed gas purge operations helped refine launchpad operating condition recommendations developed in earlier testing. Operating conditions used in flight program computer models were tested to validate the model projections. Specific operating conditions that were recommended by the JSC test team based on past test results were also tested for validation. The effects of vacuum regeneration line pressure on resulting cabin conditions was studied for high metabolic load periods, and a maximum pressure is recommended

  8. A Study on Test Technology to Diagnose the Power Apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Kim, K H; Kang, Y S; Jeon, Y K; Lee, W Y; Kang, D S; Kyu, H S; Sun, J H; Jo, K H [Korea Electrotechnology Research Institute (Korea, Republic of); Jung, J S; Mun, Y T; Lee, K H; Jung, E H; Kim, J H [Korea Water Resources Corporation (Korea, Republic of)

    1997-02-01

    In this study, we have educated KOWACO(Korea Water Resources Corporation) specialists about the insulation diagnostic technology and trained them the insulation diagnostic test and estimation method of power apparatus. The main results of this study are as follows; A. Education of basic high-voltage engineering. B. Research of insulation characteristic and deterioration mechanism in power apparatus C. Discussion on high-voltage test standard specifications. D. Study on insulation deterioration diagnostics in power apparatus. E. Field testing of insulation diagnosis in power apparatus. F. Engineering of insulation diagnostic testing apparatus to diagnose power apparatus. KOWACO specialists are able to diagnose insulation diagnostic test of power apparatus through this study. As they have instruments to diagnose power apparatus, they can do the test and estimation of the power apparatus insulation diagnosis. (author). refs., figs., tabs.

  9. Heavy Section Steel Technology Program. Part II. Intermediate vessel testing

    International Nuclear Information System (INIS)

    Whitman, G.D.

    1975-01-01

    The testing of the intermediate pressure vessels is a major activity under the Heavy Section Steel Technology Program. A primary objective of these tests is to develop or verify methods of fracture prediction, through the testing of selected structures and materials, in order that a valid basis can be established for evaluating the serviceability and safety of light-water reactor pressure vessels. These vessel tests were planned with sufficiently specific objectives that substantial quantitative weight could be given to the results. Each set of testing conditions was chosen so as to provide specific data by which analytical methods of predicting flaw growth, and in some cases crack arrest, could be evaluated. Every practical effort was made to assure that results would be relevant to some aspect of real reactor pressure vessel performance through careful control of material properties, selection of test temperatures, and design of prepared flaws. 5 references

  10. Infrared detectors and test technology of cryogenic camera

    Science.gov (United States)

    Yang, Xiaole; Liu, Xingxin; Xing, Mailing; Ling, Long

    2016-10-01

    Cryogenic camera which is widely used in deep space detection cools down optical system and support structure by cryogenic refrigeration technology, thereby improving the sensitivity. Discussing the characteristics and design points of infrared detector combined with camera's characteristics. At the same time, cryogenic background test systems of chip and detector assembly are established. Chip test system is based on variable cryogenic and multilayer Dewar, and assembly test system is based on target and background simulator in the thermal vacuum environment. The core of test is to establish cryogenic background. Non-uniformity, ratio of dead pixels and noise of test result are given finally. The establishment of test system supports for the design and calculation of infrared systems.

  11. Swarm Verification

    Science.gov (United States)

    Holzmann, Gerard J.; Joshi, Rajeev; Groce, Alex

    2008-01-01

    Reportedly, supercomputer designer Seymour Cray once said that he would sooner use two strong oxen to plow a field than a thousand chickens. Although this is undoubtedly wise when it comes to plowing a field, it is not so clear for other types of tasks. Model checking problems are of the proverbial "search the needle in a haystack" type. Such problems can often be parallelized easily. Alas, none of the usual divide and conquer methods can be used to parallelize the working of a model checker. Given that it has become easier than ever to gain access to large numbers of computers to perform even routine tasks it is becoming more and more attractive to find alternate ways to use these resources to speed up model checking tasks. This paper describes one such method, called swarm verification.

  12. On the Safety and Performance Demonstration Tests of Prototype Gen-IV Sodium-Cooled Fast Reactor and Validation and Verification of Computational Codes

    Directory of Open Access Journals (Sweden)

    Jong-Bum Kim

    2016-10-01

    Full Text Available The design of Prototype Gen-IV Sodium-Cooled Fast Reactor (PGSFR has been developed and the validation and verification (V&V activities to demonstrate the system performance and safety are in progress. In this paper, the current status of test activities is described briefly and significant results are discussed. The large-scale sodium thermal-hydraulic test program, Sodium Test Loop for Safety Simulation and Assessment-1 (STELLA-1, produced satisfactory results, which were used for the computer codes V&V, and the performance test results of the model pump in sodium showed good agreement with those in water. The second phase of the STELLA program with the integral effect tests facility, STELLA-2, is in the detailed design stage of the design process. The sodium thermal-hydraulic experiment loop for finned-tube sodium-to-air heat exchanger performance test, the intermediate heat exchanger test facility, and the test facility for the reactor flow distribution are underway. Flow characteristics test in subchannels of a wire-wrapped rod bundle has been carried out for safety analysis in the core and the dynamic characteristic test of upper internal structure has been performed for the seismic analysis model for the PGSFR. The performance tests for control rod assemblies (CRAs have been conducted for control rod drive mechanism driving parts and drop tests of the CRA under scram condition were performed. Finally, three types of inspection sensors under development for the safe operation of the PGSFR were explained with significant results.

  13. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT - REMOVAL OF PRECURSORS TO DISINFECTION BY-PRODUCTS IN DRINKING WATER, PCI MEMBRANE SYSTEMS FYNE PROCESS MODEL ROP 1434 WITH AFC-30 NANOFILTRATON AT BARROW, AK - NSF 00/19/EPADW395

    Science.gov (United States)

    Equipment testing and verification of PCI Membrane Systems Inc. Fyne Process nanofiltraton systems Model ROP 1434 equipped with a C10 module containing AFC-30 tubular membranes was conducted from 3/16-5/11/2000 in Barrow, AS. The source water was a moderate alkalinity, moderately...

  14. Verification and Performance Analysis for Embedded Systems

    DEFF Research Database (Denmark)

    Larsen, Kim Guldstrand

    2009-01-01

    This talk provides a thorough tutorial of the UPPAAL tool suite for, modeling, simulation, verification, optimal scheduling, synthesis, testing and performance analysis of embedded and real-time systems.......This talk provides a thorough tutorial of the UPPAAL tool suite for, modeling, simulation, verification, optimal scheduling, synthesis, testing and performance analysis of embedded and real-time systems....

  15. RESRAD-BUILD verification

    International Nuclear Information System (INIS)

    Kamboj, S.; Yu, C.; Biwer, B. M.; Klett, T.

    2002-01-01

    The results generated by the RESRAD-BUILD code (version 3.0) were verified with hand or spreadsheet calculations using equations given in the RESRAD-BUILD manual for different pathways. For verification purposes, different radionuclides--H-3, C-14, Na-22, Al-26, Cl-36, Mn-54, Co-60, Au-195, Ra-226, Ra-228, Th-228, and U-238--were chosen to test all pathways and models. Tritium, Ra-226, and Th-228 were chosen because of the special tritium and radon models in the RESRAD-BUILD code. Other radionuclides were selected to represent a spectrum of radiation types and energies. Verification of the RESRAD-BUILD code was conducted with an initial check of all the input parameters for correctness against their original source documents. Verification of the calculations was performed external to the RESRAD-BUILD code with Microsoft Excel to verify all the major portions of the code. In some cases, RESRAD-BUILD results were compared with those of external codes, such as MCNP (Monte Carlo N-particle) and RESRAD. The verification was conducted on a step-by-step basis and used different test cases as templates. The following types of calculations were investigated: (1) source injection rate, (2) air concentration in the room, (3) air particulate deposition, (4) radon pathway model, (5) tritium model for volume source, (6) external exposure model, (7) different pathway doses, and (8) time dependence of dose. Some minor errors were identified in version 3.0; these errors have been corrected in later versions of the code. Some possible improvements in the code were also identified

  16. Space Environmental Testing of the Electrodynamic Dust Shield Technology

    Science.gov (United States)

    Calle, Carlos I.; Mackey, P. J.; Hogue, M. D.; Johansen, M .R.; Yim, H.; Delaune, P. B.; Clements, J. S.

    2013-01-01

    NASA's exploration missions to Mars and the moon may be jeopardized by dust that will adhere to surfaces of (a) Optical systems, viewports and solar panels, (b) Thermal radiators, (c) Instrumentation, and (d) Spacesuits. We have developed an active dust mitigation technology, the Electrodynamic Dust Shield, a multilayer coating that can remove dust and also prevents its accumulation Extensive testing in simulated laboratory environments and on a reduced gravity flight shows that high dust removal performance can be achieved Long duration exposure to the space environment as part of the MISSE-X payload will validate the technology for lunar missions.

  17. Proceedings of the Joint IAEA/CSNI Specialists` Meeting on Fracture Mechanics Verification by Large-Scale Testing held at Pollard Auditorium, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    Pugh, C.E.; Bass, B.R.; Keeney, J.A. [comps.] [Oak Ridge National Lab., TN (United States)

    1993-10-01

    This report contains 40 papers that were presented at the Joint IAEA/CSNI Specialists` Meeting Fracture Mechanics Verification by Large-Scale Testing held at the Pollard Auditorium, Oak Ridge, Tennessee, during the week of October 26--29, 1992. The papers are printed in the order of their presentation in each session and describe recent large-scale fracture (brittle and/or ductile) experiments, analyses of these experiments, and comparisons between predictions and experimental results. The goal of the meeting was to allow international experts to examine the fracture behavior of various materials and structures under conditions relevant to nuclear reactor components and operating environments. The emphasis was on the ability of various fracture models and analysis methods to predict the wide range of experimental data now available. The individual papers have been cataloged separately.

  18. Verification of in-core thermal and hydraulic analysis code FLOWNET/TRUMP for the high temperature engineering test reactor (HTTR) at JAERI

    International Nuclear Information System (INIS)

    Maruyama, Soh; Sudo, Yukio; Saito, Shinzo; Kiso, Yoshihiro; Hayakawa, Hitoshi

    1989-01-01

    The FLOWNET/TRUMP code consists of a flow network analysis code 'FLOWNET' for calculations of coolant flow distribution and coolant temperature distribution in the core with a thermal conduction analysis code 'TRUMP' for calculation of temperature distribution in solid structures. The verification of FLOWNET/TRUMP was made by the comparison of the analytical results with the results of steady state experiments by the HENDEL multichannel test rig, T1-M, which consisted of twelve simulated fuel rods heated electrically and eleven hexagonal graphite fuel blocks. The T1-M simulated the one fuel column in the core. The analytical results agreed well with the results of the experiment in which the HTTR operating conditions were simulated. (orig.)

  19. Nuclear waste repository transparency technology test bed demonstrations at WIPP

    International Nuclear Information System (INIS)

    Betsill J, David; Elkins, Ned Z.; Wu, Chuan-Fu; Mewhinney, James D.; Aamodt, Paul

    2000-01-01

    Secretary of Energy, Bill Richardson, has stated that one of the nuclear waste legacy issues is ''The challenge of managing the fuel cycle's back end and assuring the safe use of nuclear power.'' Waste management (i.e., the back end) is a domestic and international issue that must be addressed. A key tool in gaining acceptance of nuclear waste repository technologies is transparency. Transparency provides information to outside parties for independent assessment of safety, security, and legitimate use of materials. Transparency is a combination of technologies and processes that apply to all elements of the development, operation, and closure of a repository system. A test bed for nuclear repository transparency technologies has been proposed to develop a broad-based set of concepts and strategies for transparency monitoring of nuclear materials at the back end of the fuel/weapons cycle. WIPP is the world's first complete geologic repository system for nuclear materials at the back end of the cycle. While it is understood that WIPP does not currently require this type of transparency, this repository has been proposed as realistic demonstration site to generate and test ideas, methods, and technologies about what transparency may entail at the back end of the nuclear materials cycle, and which could be applicable to other international repository developments. An integrated set of transparency demonstrations was developed and deployed during the summer, and fall of 1999 as a proof-of-concept of the repository transparency technology concept. These demonstrations also provided valuable experience and insight into the implementation of future transparency technology development and application. These demonstrations included: Container Monitoring Rocky Flats to WIPP; Underground Container Monitoring; Real-Time Radiation and Environmental Monitoring; Integrated level of confidence in the system and information provided. As the world's only operating deep geologic

  20. IFE chamber technology testing program in NIF and chamber development test plan

    International Nuclear Information System (INIS)

    Abdou, M.A.

    1995-01-01

    Issues concerning chamber technology testing program in NIF involving: criteria for evaluation/prioritization of experiments, engineering scaling requirements for test article design and material selection and R and D plan prior to NIF testing were addressed in this paper. In order to maximize the benefits of testing program in NIF, the testing in NIF should provide the experimental data relevant to DEMO design choice or to DEMO design predictive capability by utilizing engineering scaling test article designs. Test plans were developed for 2 promising chamber design concepts. Early testing in non-fusion/non-ignition prior to testing in ignition facility serves a critical role in chamber R and D test plans in order to reduce the risks and costs of the more complex experiments in NIF