  1. A model undergraduate research institute for study of emerging non-contact measurement technologies and techniques

    Science.gov (United States)

    Dvonch, Curt; Smith, Christopher; Bourne, Stefanie; Blandino, Joseph R.; Miles, Jonathan J.

    2006-04-01

    The Infrared Development and Thermal Structures Laboratory (IDTSL) is an undergraduate research laboratory in the College of Integrated Science and Technology (CISAT) at James Madison University (JMU) in Harrisonburg, Virginia. During the 1997-98 academic year, Dr. Jonathan Miles established the IDTSL at JMU with the support of a collaborative research grant from the NASA Langley Research Center and with additional support from the College of Integrated Science and Technology at JMU. The IDTSL supports research and development efforts that feature non-contact thermal and mechanical measurements and advance the state of the art. These efforts all entail undergraduate participation intended to significantly enrich their technical education. The IDTSL is funded by major government organizations and the private sector and provides a unique opportunity to undergraduates who wish to participate in projects that push the boundaries of non-contact measurement technologies, and provides a model for effective hands-on, project oriented, student-centered learning that reinforces concepts and skills introduced within the Integrated Science and Technology (ISAT) curriculum. The lab also provides access to advanced topics and emerging measurement technologies; fosters development of teaming and communication skills in an interdisciplinary environment; and avails undergraduates of professional activities including writing papers, presentation at conferences, and participation in summer internships. This paper provides an overview of the Infrared Development and Thermal Structures Laboratory, its functionality, its record of achievements, and the important contribution it has made to the field of non-contact measurement and undergraduate education.

  2. Measurement of Walking Ground Reactions in Real-Life Environments: A Systematic Review of Techniques and Technologies.

    Science.gov (United States)

    Shahabpoor, Erfan; Pavic, Aleksandar

    2017-09-12

    Monitoring natural human gait in real-life environments is essential in many applications, including quantification of disease progression, monitoring the effects of treatment, and monitoring alteration of performance biomarkers in professional sports. Nevertheless, developing reliable and practical techniques and technologies necessary for continuous real-life monitoring of gait is still an open challenge. A systematic review of English-language articles from scientific databases including Scopus, ScienceDirect, Pubmed, IEEE Xplore, EBSCO and MEDLINE were carried out to analyse the 'accuracy' and 'practicality' of the current techniques and technologies for quantitative measurement of the tri-axial walking ground reactions outside the laboratory environment, and to highlight their strengths and shortcomings. In total, 679 relevant abstracts were identified, 54 full-text papers were included in the paper and the quantitative results of 17 papers were used for meta-analysis and comparison. Three classes of methods were reviewed: (1) methods based on measured kinematic data; (2) methods based on measured plantar pressure; and (3) methods based on direct measurement of ground reactions. It was found that all three classes of methods have competitive accuracy levels with methods based on direct measurement of the ground reactions showing highest accuracy while being least practical for long-term real-life measurement. On the other hand, methods that estimate ground reactions using measured body kinematics show highest practicality of the three classes of methods reviewed. Among the most prominent technical and technological challenges are: (1) reducing the size and price of tri-axial load-cells; (2) improving the accuracy of orientation measurement using IMUs; (3) minimizing the number and optimizing the location of required IMUs for kinematic measurement; (4) increasing the durability of pressure insole sensors, and (5) enhancing the robustness and versatility of the

  3. Measurement of Walking Ground Reactions in Real-Life Environments: A Systematic Review of Techniques and Technologies

    Directory of Open Access Journals (Sweden)

    Erfan Shahabpoor

    2017-09-01

    Full Text Available Monitoring natural human gait in real-life environments is essential in many applications, including quantification of disease progression, monitoring the effects of treatment, and monitoring alteration of performance biomarkers in professional sports. Nevertheless, developing reliable and practical techniques and technologies necessary for continuous real-life monitoring of gait is still an open challenge. A systematic review of English-language articles from scientific databases including Scopus, ScienceDirect, Pubmed, IEEE Xplore, EBSCO and MEDLINE were carried out to analyse the ‘accuracy’ and ‘practicality’ of the current techniques and technologies for quantitative measurement of the tri-axial walking ground reactions outside the laboratory environment, and to highlight their strengths and shortcomings. In total, 679 relevant abstracts were identified, 54 full-text papers were included in the paper and the quantitative results of 17 papers were used for meta-analysis and comparison. Three classes of methods were reviewed: (1 methods based on measured kinematic data; (2 methods based on measured plantar pressure; and (3 methods based on direct measurement of ground reactions. It was found that all three classes of methods have competitive accuracy levels with methods based on direct measurement of the ground reactions showing highest accuracy while being least practical for long-term real-life measurement. On the other hand, methods that estimate ground reactions using measured body kinematics show highest practicality of the three classes of methods reviewed. Among the most prominent technical and technological challenges are: (1 reducing the size and price of tri-axial load-cells; (2 improving the accuracy of orientation measurement using IMUs; (3 minimizing the number and optimizing the location of required IMUs for kinematic measurement; (4 increasing the durability of pressure insole sensors, and (5 enhancing the robustness and

  4. A computationally assisted spectroscopic technique to measure secondary electron emission coefficients in technological rf plasmas

    Science.gov (United States)

    Berger, Birk; Schulze, Julian; Daksha, Manaswi; Schuengel, Edmund; Koepke, Mark; Korolov, Ihor; Derzsi, Aranka; Donko, Zoltan

    2016-09-01

    A Computationally Assisted Spectroscopic Technique to measure secondary electron emission coefficients (y-CAST) in capacitive rf plasmas is proposed. This non-intrusive, sensitive diagnostic is based on a combination of Phase Resolved Optical Emission Spectroscopy and PIC simulations. Under most conditions in electropositive plasmas the spatio-temporally resolved electron-impact excitation rate features two distinct maxima adjacent to each electrode at different times within one rf period. One maximum is the consequence of an energy gain of the electrons due to sheath expansion. The second maximum is produced by electrons accelerated towards the plasma bulk by the sheath electric field at the time of maximum voltage drop across the sheath. Due to the different excitation mechanisms the ratio of the intensities of these maxima is very sensitive to y, which allows for its determination via comparing the experimentally measured excitation profiles with corresponding simulation data obtained with various y-coefficients. This diagnostic is tested here in a geometrically symmetric reactor, for stainless steel electrodes and argon gas. An effective secondary electron emission coefficient of y = 0.067+-0.010 is obtained, which is in excellent agreement with previous experimental results.

  5. Optical pulses, lasers, measuring techniques

    CERN Document Server

    Früngel, Frank B A

    1965-01-01

    High Speed Pulse Technology: Volume II: Optical Pulses - Lasers - Measuring Techniques focuses on the theoretical and engineering problems that result from the capacitor discharge technique.This book is organized into three main topics: light flash production from a capacitive energy storage; signal transmission and ranging systems by capacitor discharges and lasers; and impulse measuring technique. This text specifically discusses the air spark under atmospheric conditions, industrial equipment for laser flashing, and claims for light transmitting system. The application of light impulse sign

  6. A technique for measurement of earth station antenna G/T by radio stars and Applications Technology Satellites.

    Science.gov (United States)

    Kochevar, H. J.

    1972-01-01

    A new technique has been developed to accurately measure the G/T of a small aperture antenna using geostationary satellites and the well established radio star method. A large aperture antenna having the capability of accurately measuring its G/T by using a radio star of known power density is used to obtain an accurate G/T to use as a reference. The CNR of both the large and small aperture antennas are then measured using an Applications Technology Satellite (ATS). After normalizing the two C/N ratios to the large antenna system noise temperature the G/T or the gain G of the small aperture antenna can then be determined.

  7. Remote Attitude Measurement Techniques.

    Science.gov (United States)

    1982-12-01

    are other factors which will influence the selection of the communications means. One major factor is the selection of the technology to be used. Aside...electrooptical devices with partitioned focal planes, and the char- acteristics of these techniques influence how the focal planes are partitioned. G. FOCAL...a televison camera). The incident illumination produces a non-uniformity on the scanned side of the sensitive material which can be modeled as an

  8. Process measuring techniques; Prozessmesstechnik

    Energy Technology Data Exchange (ETDEWEB)

    Freudenberger, A.

    2000-07-01

    This introduction into measurement techniques for chemical and process-technical plant in science and industry describes in detail the methods used to measure basic quantities. Most prominent are modern measuring techniques by means of ultrasound, microwaves and the Coriolis effect. Alongside physical and measuring technique fundamentals, the practical applications of measuring devices are described. Calculation examples are given to illustrate the subject matter. The book addresses students of physical engineering, process engineering and environmental engineering at technical schools as well as engineers of other disciplines wishing to familiarize themselves with the subject of process measurement techniques. (orig.) [German] Diese Einfuehrung in die Messtechnik fuer chemische und verfahrens-technische Forschungs- und Produktionsanlagen beschreibt ausfuehrlich die Methoden zur Messung der Basisgroessen. Moderne Messverfahren mit Ultraschall, Mikrowellen und Coriolis-Effekt stehen dabei im Vordergrund. Beruecksichtigung finden sowohl die physikalischen und messtechnischen Grundlagen als auch die praktischen Anwendungen der Geraete. Berechnungsbeispiele dienen der Erlaeuterung und Vertiefung des Stoffes. Angesprochen sind Studenten der Ingenieurstufengaenge Physikalische Technik und Verfahrens- und Umwelttechnik an Fachhochschulen als auch Ingenieure anderer Fachrichtungen, die sich in das Gebiet der Prozessmesstechnik einarbeiten wollen. (orig.)

  9. MEMS Technology Sensors as a More Advantageous Technique for Measuring Foot Plantar Pressure and Balance in Humans

    Directory of Open Access Journals (Sweden)

    Clara Sanz Morère

    2016-01-01

    Full Text Available Locomotor activities are part and parcel of daily human life. During walking or running, feet are subjected to high plantar pressure, leading sometimes to limb problems, pain, or foot ulceration. A current objective in foot plantar pressure measurements is developing sensors that are small in size, lightweight, and energy efficient, while enabling high mobility, particularly for wearable applications. Moreover, improvements in spatial resolution, accuracy, and sensitivity are of interest. Sensors with improved sensing techniques can be applied to a variety of research problems: diagnosing limb problems, footwear design, or injury prevention. This paper reviews commercially available sensors used in foot plantar pressure measurements and proposes the utilization of pressure sensors based on the MEMS (microelectromechanical systems technique. Pressure sensors based on this technique have the capacity to measure pressure with high accuracy and linearity up to high pressure levels. Moreover, being small in size, they are highly suitable for this type of measurement. We present two MEMS sensor models and study their suitability for the intended purpose by performing several experiments. Preliminary results indicate that the sensors are indeed suitable for measuring foot plantar pressure. Importantly, by measuring pressure continuously, they can also be utilized for body balance measurements.

  10. New measurements techniques

    DEFF Research Database (Denmark)

    Torras Rosell, Antoni

    of the pressure encountered by the ‘sensing’ light when traveling through the acoustic field. Far from being a limitation, this integral principle is exploited for sound field visualization using tomography. The most innovative contribution of this PhD project is the applicability of the acousto-optic measuring......Acoustic measurements are traditionally based on transducers, and in particular, the most advanced measurement techniques are nowadays based on transducer arrays. This poses a fundamental problem, namely the influence of the transducer itself on the actual properties of sound when the transducer...... is immersed into the sound field. Typically, this influence is assumed to be negligible when the size of the transducer is small compared to the wavelength of the sound wave, or is rendered negligible by using a transducerbased correction that depends on the frequency. Either solution introduces additional...

  11. A Technique to Measure Focal Length of a Lens with no Bulk Motion using Tunable Optics and Optical MEMS Technology

    CERN Document Server

    Reza, Syed Azer

    2016-01-01

    This paper presents a motion-free technique for characterizing the focal length of any spherical convex or concave lens. The measurement system uses a Gaussian Beam from a Laser Source (LS), an Electronically Controlled Variable Focus Lens (ECVFL), a Digital Micromirror Device (DMD) and a Photo-Detector (PD). As the proposed method does not involve any motion-stages or other moving components, the focal length is measured without requiring any mechanical motion of bulk components. The method requires measuring the spot size of the Gaussian Beam at the DMD plane for various settings of the ECVFL focal length. These beam spot size measurements, are used to estimate the focal length of a lens sample by employing standard polynomial-fitting techniques. Due to the inherent motion-free nature of the proposed setup, the measurements are fast, repeatable, reliable and ideal for use in industrial lens production, manufacturing of imaging systems and sensitive laboratory experiments. Using a DMD and an ECVFL also allow...

  12. Application of indirect stress measurement techniques (non strain gauge based technology) to quantify stress environments in mines

    CSIR Research Space (South Africa)

    Stacey, TR

    2002-03-01

    Full Text Available Reliable values of in situ stress are essential for the valid modelling of mine layouts. Available non-strain gauge methods are reviewed as potential practical techniques for South African mines. From this review it is concluded that the most...

  13. Helium II level measurement techniques

    Science.gov (United States)

    Celik, D.; Hilton, D. K.; Zhang, T.; Van Sciver, S. W.

    2001-05-01

    In this paper, a survey of cryogenic liquid level measurement techniques applicable to superfluid helium (He II) is given. The survey includes both continuous and discrete measurement techniques. A number of different probes and controlling circuits for this purpose have been described in the literature. They fall into one of the following categories: capacitive liquid level gauges, superconducting wire liquid level gauges, thermodynamic (heat transfer-based) liquid level gauges, resistive gauges, ultrasound and transmission line-based level detectors. The present paper reviews these techniques and their suitability for He II service. In addition to these methods, techniques for measuring the total liquid volume and mass gauging are also discussed.

  14. Reflection of an In-service Education Course Programme for Science and Technology Teachers about Alternative Measurement and Assessment Techniques: Trabzon Sample

    Directory of Open Access Journals (Sweden)

    Sibel Er Nas

    2008-12-01

    Full Text Available Abstract- The aim of this study is to investigate the effectiveness of an in-service education course program including alternative measurement and assessment techniques on participant teachers skills and perspectives. Case study was used in this study. The sample of the study consisted of six voluntary science and technology teachers working in Trabzon. Researchers diary, document analysis and semi-structured interviews were used for data collection. Qualitative data analysis was used in this study. Holistic rubric prepared by researcher was used for document analysis. Matris forms including codes were used for interviews analysis. At the end of the study, it was concluded that in-service education course program had positive effects on teachers skills and their perspectives of using alternative assessment techniques in their lessons. In addition, teachers had difficulty in preparing analytic rubrics during the in-service education course period. Recommendations were presented on the arrangement of in-service education course program which include lots of activities and may contribute teachers skills using alternative assessment techniques.

  15. Thermal measurements and inverse techniques

    CERN Document Server

    Orlande, Helcio RB; Maillet, Denis; Cotta, Renato M

    2011-01-01

    With its uncommon presentation of instructional material regarding mathematical modeling, measurements, and solution of inverse problems, Thermal Measurements and Inverse Techniques is a one-stop reference for those dealing with various aspects of heat transfer. Progress in mathematical modeling of complex industrial and environmental systems has enabled numerical simulations of most physical phenomena. In addition, recent advances in thermal instrumentation and heat transfer modeling have improved experimental procedures and indirect measurements for heat transfer research of both natural phe

  16. 3 - Dimensional Body Measurement Technology

    Institute of Scientific and Technical Information of China (English)

    ZHOU Xu-dong; LI Yan-mei

    2002-01-01

    3 - dimensional body measurement technology, the basis of developing high technology in industry, accelerates digital development of aplparel industry. This paper briefly introduces the history of 3 - dimensional body measurement technology, and recounts the principle and primary structure of some types of 3 - dimensional automatic body measurement system. With this understanding, it discusses prospect of 3- dimensional CAD and virtual technology used in apparel industry.

  17. Atmospheric Ice Accretion Measurement Techniques

    Directory of Open Access Journals (Sweden)

    M Virk

    2016-09-01

    Full Text Available Atmospheric icing on structures has proven to be an area of concern in many cold climate geographical regions like arctic and alpine. Difficulties encountered by the communication, construction and power industries in these areas are the subject of intense investigations for researchers from decades. Three main methods of investigation are generally employed by researchers to study atmospheric ice accretion on structures: a continuous field measurements, b lab based simulations using icing wind tunnel & c numerical modelling. This paper presents a brief review study of various techniques to understand and measure the atmospheric ice accretion on structures, anti/de icing techniques and important parameters for numerical modelling of atmospheric ice accretion.

  18. A measurement technique for hydroxyacetone

    Energy Technology Data Exchange (ETDEWEB)

    Klotz, P.J.

    1999-10-04

    Hydroxyacetone (HA) is mainly produced in the atmosphere from oxidation of hydrocarbons of the type, CH{sub 3}(R)C{double{underscore}bond}CH{sub 2}. Tuazon and Atkinson (1990) reported HA yield of 41% from the OH-initiated oxidation of methacrolein in the presence of NOx. Since methacrolein is a major product of isoprene oxidation (Carter and Atkinson, 1996), isoprene, a key biogenic hydrocarbon, is therefore expected to be an important source for HA. Consequently, knowledge of ambient concentration of HA would provide information needed to examine the applicability of isoprene reaction mechanisms developed in laboratory and to assess the contribution of isoprene to photooxidant production. The commonly used GC-FID technique involving cryo-focusing is unsuitable for HA owing to HA's thermal instability. When subjected to a temperature of 100 C for only a few seconds, HA was found to disappear completely. Since HA is highly soluble in water, the authors developed a wet chemical technique similar in principle to the one they reported earlier, namely, derivatization following liquid scrubbing. To increase the sensitivity, they adopted a fluorescence detection scheme based on o-phthaldialdehyde (OPA) chemistry. The technique was deployed in the field during two measurement periods at a NARSTO site located on Long Island, New York. The authors report the principle and the operation of this technique and the results obtained from these field studies.

  19. Developments in luminescence measurement techniques

    DEFF Research Database (Denmark)

    Thomsen, Kristina Jørkov; Bøtter-Jensen, L.; Denby, Phil M.

    2006-01-01

    We report on our continuing investigation and development of new measurement facilities for use in irradiation, optical stimulation and luminescence signal detection; these facilities have potential application to all forms of luminescence-based retrospective dosimetry, and are particularly...... intended for use with the Riso TL/OSL reader. We have investigated the potential of new more powerful blue (455 nm) and green (530nm) LEDs, and of gated counting combined with pulsed stimulation light techniques using conventional LEDs. Measurement of time-resolved OSL has resulted in a method of real......; both types are very stable and reproducible. Other recent developments include the modification of a Riso reader to measure both thermally and optically stimulated electrons (TSE and OSE) from granular or chip phosphors. (c) 2006 Elsevier Ltd. All rights reserved....

  20. A MEASUREMENT TECHNIQUE FOR HYDROXYACETONE.

    Energy Technology Data Exchange (ETDEWEB)

    KLOTZ,P.J.

    1999-10-04

    Hydroxyacetone (HA) is mainly produced in the atmosphere from oxidation of hydrocarbons of the type, CH{sub 3}(R)C=CH{sub 2}. Tuazon and Atkinson (1990) reported HA yield of 41% from the OH-initiated oxidation of methacrolein in the presence of NO{sub x}. Since methacrolein is a major product of isoprene oxidation (Carter and Atkinson, 1996), isoprene, a key biogenic hydrocarbon, is therefore expected to be an important source for HA. Consequently, knowledge of ambient concentration of HA would provide information needed to examine the applicability of isoprene reaction mechanisms developed in laboratory and to assess the contribution of isoprene to photooxidant production. The commonly used GC-FID technique involving cryo-focusing is unsuitable for HA owing to HA's thermal instability. When subjected to a temperature of 100 C for only a few seconds, HA was found to disappear completely. Since HA is highly soluble in water (it's Henry's law constant being {approx}2 x 10{sup 4} M atm{sup -1} at 20 C, Zhou and Lee, unpublished data), we developed a wet chemical technique similar in principle to the one we reported earlier (Lee and Zhou, 1993), namely, based on derivatization following liquid scrubbing. To increase the sensitivity, we adopted a fluorescence detection scheme based on o-phthaldialdehyde (OPA) chemistry. The technique was deployed in the field during two measurement periods at a NARSTO site located on Long Island (LI), New York. We report the principle and the operation of this technique and the results obtained from these field studies.

  1. POSIVA groundwater flow measuring techniques

    Energy Technology Data Exchange (ETDEWEB)

    Oehberg, A. [Saanio and Riekkola Consulting Engineers, Helsinki (Finland); Rouhiainen, P. [PRG-Tec Oy (Finland)

    2000-08-01

    Posiva Oy has carried out site characterisation for the final disposal of spent nuclear fuel in Finland since 1987. To meet the demanding needs to measure the hydraulic parameters in bedrock Posiva launched development of new flowmeter techniques including measuring methods and equipment in co-operation with PRG-Tec Oy. The techniques have been tested and used in the ongoing site investigations in Finland, in the underground Hard Rock Laboratory (HRL) at Aespoe in Sweden and in URL in Canada. The new methods are called difference flow and transverse flow methods. The difference flow method includes two modes, normal and detailed flow logging methods. In the normal mode the flow rate measurement is based on thermal pulse and thermal dilution methods, in the detailed logging mode only on thermal dilution method. The measuring ranges for flow rate with thermal pulse and dilution methods are 0.1-10 ml/min and 2-5000 ml/min, respectively. The difference flow method(normal mode) for small flows (0.1-10 ml/min) is based on measuring the pulse transit time and direction of a thermal pulse in the sensor. For high flows (2-5000 ml/min) the method is based on thermal dilution rate of a sensor. Direction is measured with monitoring thermistors. Inflow or outflow in the test interval is created due to natural or by pumping induced differences between heads in the borehole water and groundwater around the borehole. The single point resistance (and the temperature of borehole water) measurement is carried out simultaneously with the difference flow measurements, both in normal and detailed flow logging modes, while the tool is moving. The result is utilised for checking the exact depth of the tool. As the result a continuous log is obtained from which single fractures can be detected. The transverse flowmeter is able to measure the groundwater flow across a borehole. A special packer system guides the flow through the flow sensors. Four inflatable seals between conventional

  2. Metrology of vibration measurements by laser techniques

    Science.gov (United States)

    von Martens, Hans-Jürgen

    2008-06-01

    Metrology as the art of careful measurement has been understood as uniform methodology for measurements in natural sciences, covering methods for the consistent assessment of experimental data and a corpus of rules regulating application in technology and in trade and industry. The knowledge, methods and tools available for precision measurements can be exploited for measurements at any level of uncertainty in any field of science and technology. A metrological approach to the preparation, execution and evaluation (including expression of uncertainty) of measurements of translational and rotational motion quantities using laser interferometer methods and techniques will be presented. The realization and dissemination of the SI units of motion quantities (vibration and shock) have been based on laser interferometer methods specified in international documentary standards. New and upgraded ISO standards are reviewed with respect to their suitability for ensuring traceable vibration measurements and calibrations in an extended frequency range of 0.4 Hz to higher than 100 kHz. Using adequate vibration exciters to generate sufficient displacement or velocity amplitudes, the upper frequency limits of the laser interferometer methods specified in ISO 16063-11 for frequencies procedures (i.e. measurement uncertainty 0.05 % at frequencies <= 10 kHz, <= 1 % up to 100 kHz).

  3. Superhydrophobic Materials Technology-PVC Bonding Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Hunter, Scott R. [Oak Ridge National Laboratory; Efird, Marty [VeloxFlow, LLC

    2013-05-03

    The purpose of the technology maturation project was to develop an enhanced application technique for applying diatomaceous earth with pinned polysiloxane oil to PVC pipes and materials. The oil infiltration technique is applied as a spray of diluted oil in a solvent onto the superhydrophobic diatomaceous earth substrate. This makes the surface take on the following characteristics: wet-cleanable; anti-biofouling; waterproof; and anti-corrosion. The project involved obtaining input and supplies from VeloxFlow and the development of successful techniques that would quickly result in a commercial license agreement with VeloxFlow and other companies that use PVC materials in a variety of other fields of use.

  4. An acoustic mode measurement technique

    Science.gov (United States)

    Joppa, P. D.

    1984-10-01

    Turbomachinery noise propagates in aircraft jet engine ducts in a complicated manner. Measurement of this propagation is useful both to identify source mechanisms and to design efficient linings. A practical method of making these measurements has been developed, using linear arrays of equally spaced microphones mounted flush with the duct wall. Circumferential or axial arrays are analyzed by spatial Fourier transform, giving sound level as a function of spinning order or axial wavenumber respectively. Complex demodulation is used to acquire data in a modest bandwidth around a high frequency of interest. A joint NASA/Boeing test of the system used 32 microphones in a JT15D turbofan engine inlet. A 400-Hz bandwidth centered at blade passage frequency and at half blade passage frequency was studied. The theoretically predicted modes were clearly seen at blade passage frequency; broadband noise at half blade passage frequency was biased towards modes corotating with the fan. Interference between similar modes was not a significant problem. A lining design study indicated a 15 percent improvement in lining efficiency was possible when mode data were used, for this particular engine. The technique has proven reliable and useful for source diagnostics and lining design.

  5. Wood Technology: Techniques, Processes, and Products

    Science.gov (United States)

    Oatman, Olan

    1975-01-01

    Seven areas of wood technology illustrates applicable techniques, processes, and products for an industrial arts woodworking curriculum. They are: wood lamination; PEG (polyethylene glycol) diffusion processes; wood flour and/or particle molding; production product of industry; WPC (wood-plastic-composition) process; residential construction; and…

  6. Ultrasonic measurements and technologies

    CERN Document Server

    Kočiš, Štefan

    1996-01-01

    An impulse for writing this book has originated from the effort to sum­ marize and publicise the acquired results of a research team at the De­ partment of Automation of the Faculty of Electrical Engineering and In­ formatics, Slovak Technical University in Bratislava. The research team has been involved for a long time with control problems for machine production mechanisms and, in recent (approximately 15) years, its effort was aimed mostly at the control of electrical servosystems of robots. Within this scope, the members of the authors' staff solved the State Re­ search Task Ultrasonic sensing of the position of a robot hand, which was coordinated by the Institute of Technical Cybernetics of the Slovak Academy of Sciences in Bratislava. The problem was solved in a complex way, i.e. from a conceptual de­ sign of the measurement, through the measurement and evaluation sys­ tem, up to connection to the control system of a robot. Compensation of the atmospheric influence on the precision of measurement,...

  7. Granulation techniques and technologies: recent progresses.

    Science.gov (United States)

    Shanmugam, Srinivasan

    2015-01-01

    Granulation, the process of particle enlargement by agglomeration technique, is one of the most significant unit operations in the production of pharmaceutical dosage forms, mostly tablets and capsules. Granulation process transforms fine powders into free-flowing, dust-free granules that are easy to compress. Nevertheless, granulation poses numerous challenges due to high quality requirement of the formed granules in terms of content uniformity and physicochemical properties such as granule size, bulk density, porosity, hardness, moisture, compressibility, etc. together with physical and chemical stability of the drug. Granulation process can be divided into two types: wet granulation that utilize a liquid in the process and dry granulation that requires no liquid. The type of process selection requires thorough knowledge of physicochemical properties of the drug, excipients, required flow and release properties, to name a few. Among currently available technologies, spray drying, roller compaction, high shear mixing, and fluid bed granulation are worth of note. Like any other scientific field, pharmaceutical granulation technology also continues to change, and arrival of novel and innovative technologies are inevitable. This review focuses on the recent progress in the granulation techniques and technologies such as pneumatic dry granulation, reverse wet granulation, steam granulation, moisture-activated dry granulation, thermal adhesion granulation, freeze granulation, and foamed binder or foam granulation. This review gives an overview of these with a short description about each development along with its significance and limitations.

  8. The Technology to Train Techniques in Sports

    Directory of Open Access Journals (Sweden)

    Vladimir E. Afonshin

    2016-03-01

    Full Text Available The training session of technical techniques is proposed to conduct on the playing ground where computer-controlled light emitters create allowed and unallowed light dynamic zones. Each athlete is to be placed in one of the allowed zones and to execute with an implement some techniques directed with his breast on the light guide mark created outside the allowed zone. The athlete holding an implement is not allowed to go out of the permitted area. In the course of the training session unpredictably for an athlete the position, the shape and the area of the permitted and unallowed zones is changed. The athlete’s going into the unallowed zone or performing techniques in the position not-oriented on the guide mark is considered to be an error. If the errors are none, the allowed zone area is reduced and the intensity of the session is increased until the athlete commits an error. By the minimum square of the allowed zone, the maximum speed of its movement that the athlete performing the exercise does not commit any errors, they evaluate the athlete’s technical skill. The proposed technology facilitates in faster mastering the play technique, unlocking the individual technical features and enhancing them at any stage of the professional career. The technology can be used for the technical training of athletes of different professional profiles specializing in football, hockey, handball, basketball and other sports that require implement handling.

  9. Triple-Pulse Integrated Path Differential Absorption Lidar for Carbon Dioxide Measurement - Novel Lidar Technologies and Techniques with Path to Space

    Science.gov (United States)

    Singh, Upendra N.; Refaat, Tamer F.; Petros, Mulugeta

    2017-01-01

    The societal benefits of understanding climate change through identification of global carbon dioxide sources and sinks led to the desired NASA's active sensing of carbon dioxide emissions over nights, days, and seasons (ASCENDS) space-based missions of global carbon dioxide measurements. For more than 15 years, NASA Langley Research Center (LaRC) have developed several carbon dioxide active remote sensors using the differential absorption lidar (DIAL) technique operating at the two-micron wavelength. Currently, an airborne two-micron triple-pulse integrated path differential absorption (IPDA) lidar is under development. This IPDA lidar measures carbon dioxide as well as water vapor, the dominant interfering molecule on carbon dioxide remote sensing. Advancement of this triple-pulse IPDA lidar development is presented.

  10. Surveying techniques in vibration measurement

    Directory of Open Access Journals (Sweden)

    Kuras Przemyslaw

    2015-01-01

    Full Text Available In order to determine the actual dynamic characteristics of engineering structures, it is necessary to perform direct measurements. The paper focuses on the problem of using various devices to measure vibration, with particular emphasis on surveying instruments. The main tool used in this study is the radar interferometer, which has been compared to: robotic total station, GNSS receivers and sensors (accelerometer and encoder. The results of four dynamic experiments are presented. They were performed on: industrial chimney, drilling tower, railway bridge and pedestrian footbridge. The obtained results have been discussed in terms of the requirements imposed by the standard ISO 4866:2010.

  11. Advanced in-flight measurement techniques

    CERN Document Server

    Lawson, Nicholas; Jentink, Henk; Kompenhans, Jürgen

    2013-01-01

    The book presents a synopsis of the main results achieved during the 3 year EU-project "Advanced Inflight Measurement Techniques (AIM)" which applied advanced image based measurement techniques to industrial flight testing. The book is intended to be not only an overview on the AIM activities but also a guide on the application of advanced optical measurement techniques for future flight testing. Furthermore it is a useful guide for engineers in the field of experimental methods and flight testing who face the challenge of a future requirement for the development of highly accurate non-intrusive in-flight measurement techniques.

  12. Measurement Error with Different Computer Vision Techniques

    Science.gov (United States)

    Icasio-Hernández, O.; Curiel-Razo, Y. I.; Almaraz-Cabral, C. C.; Rojas-Ramirez, S. R.; González-Barbosa, J. J.

    2017-09-01

    The goal of this work is to offer a comparative of measurement error for different computer vision techniques for 3D reconstruction and allow a metrological discrimination based on our evaluation results. The present work implements four 3D reconstruction techniques: passive stereoscopy, active stereoscopy, shape from contour and fringe profilometry to find the measurement error and its uncertainty using different gauges. We measured several dimensional and geometric known standards. We compared the results for the techniques, average errors, standard deviations, and uncertainties obtaining a guide to identify the tolerances that each technique can achieve and choose the best.

  13. MEASUREMENT ERROR WITH DIFFERENT COMPUTER VISION TECHNIQUES

    Directory of Open Access Journals (Sweden)

    O. Icasio-Hernández

    2017-09-01

    Full Text Available The goal of this work is to offer a comparative of measurement error for different computer vision techniques for 3D reconstruction and allow a metrological discrimination based on our evaluation results. The present work implements four 3D reconstruction techniques: passive stereoscopy, active stereoscopy, shape from contour and fringe profilometry to find the measurement error and its uncertainty using different gauges. We measured several dimensional and geometric known standards. We compared the results for the techniques, average errors, standard deviations, and uncertainties obtaining a guide to identify the tolerances that each technique can achieve and choose the best.

  14. Track etching technique in membrane technology

    Energy Technology Data Exchange (ETDEWEB)

    Apel, P. E-mail: apel@lnr.jinr.ru

    2001-06-01

    Track membrane (TM) technology is an example of industrial application of track etching technique. Track-etch membranes offer distinct advantages over conventional membranes due to their precisely determined structure. Their pore size, shape and density can be varied in a controllable manner so that a membrane with the required transport and retention characteristics can be produced. The use of heavy ion accelerators made it possible to vary LET of track-forming particles, angle distribution of pore channels and pore lengths. So far the track formation and etching process has been studied in much detail for several polymeric materials. Today we understand determining factors and have numerous empirical data enabling us to manufacture any particular product based on polyethylene terephthalate (PET) or polycarbonate (PC) films. Pore shape can be made cylindrical, conical, funnel-like, or cigar-like at will. A number of modification methods has been developed for creating TMs with special properties and functions. Applications of 'conventional' track membranes can be categorized into three groups: process filtration, cell culture, and laboratory filtration. The use in biology stands out among other areas. Nuclear track pores find diverse applications as model systems and as templates for the synthesis of micro- and nanostructures.

  15. Experimental Techniques for Thermodynamic Measurements of Ceramics

    Science.gov (United States)

    Jacobson, Nathan S.; Putnam, Robert L.; Navrotsky, Alexandra

    1999-01-01

    Experimental techniques for thermodynamic measurements on ceramic materials are reviewed. For total molar quantities, calorimetry is used. Total enthalpies are determined with combustion calorimetry or solution calorimetry. Heat capacities and entropies are determined with drop calorimetry, differential thermal methods, and adiabatic calorimetry . Three major techniques for determining partial molar quantities are discussed. These are gas equilibration techniques, Knudsen cell methods, and electrochemical techniques. Throughout this report, issues unique to ceramics are emphasized. Ceramic materials encompass a wide range of stabilities and this must be considered. In general data at high temperatures is required and the need for inert container materials presents a particular challenge.

  16. Measurement of solid concentration using Terahertz technique

    Institute of Scientific and Technical Information of China (English)

    Liu Yi'an; Huang Zhiyao; Ji Haifeng; Wang Baoliang; Li Haiqing

    2007-01-01

    Terahertz(THz)technique is a new measurement technique that has emerged in recent years. For the measurement of solid concentration, a radiation attenuation method and a phase delay method were developed, which are based on the Beer-Lambert law. Experimental work was carried out on a terahertz time-domain spectroscopy system (THz-TDS). Results obtained verify that the terahertz technique may provide a possible new solution to the problem of solid concentration measurement and the two proposed measurement methods are effective. Experiment results also indicate that the phase delay method is more accurate than the radiation attenuation method and the size of the particles affects the measurement results of both methods.

  17. Multidirectional mobilities: Advanced measurement techniques and applications

    Science.gov (United States)

    Ivarsson, Lars Holger

    Today high noise-and-vibration comfort has become a quality sign of products in sectors such as the automotive industry, aircraft, components, households and manufacturing. Consequently, already in the design phase of products, tools are required to predict the final vibration and noise levels. These tools have to be applicable over a wide frequency range with sufficient accuracy. During recent decades a variety of tools have been developed such as transfer path analysis (TPA), input force estimation, substructuring, coupling by frequency response functions (FRF) and hybrid modelling. While these methods have a well-developed theoretical basis, their application combined with experimental data often suffers from a lack of information concerning rotational DOFs. In order to measure response in all 6 DOFs (including rotation), a sensor has been developed, whose special features are discussed in the thesis. This transducer simplifies the response measurements, although in practice the excitation of moments appears to be more difficult. Several excitation techniques have been developed to enable measurement of multidirectional mobilities. For rapid and simple measurement of the loaded mobility matrix, a MIMO (Multiple Input Multiple Output) technique is used. The technique has been tested and validated on several structures of different complexity. A second technique for measuring the loaded 6-by-6 mobility matrix has been developed. This technique employs a model of the excitation set-up, and with this model the mobility matrix is determined from sequential measurements. Measurements on ``real'' structures show that both techniques give results of similar quality, and both are recommended for practical use. As a further step, a technique for measuring the unloaded mobilities is presented. It employs the measured loaded mobility matrix in order to calculate compensation forces and moments, which are later applied in order to compensate for the loading of the

  18. High-voltage test and measuring techniques

    Energy Technology Data Exchange (ETDEWEB)

    Hauschild, Wolfgang; Lemke, Eberhard

    2014-04-01

    Reflects the unit of both HV testing and measuring technique. Intended as an ''application guide'' for the relevant IEC standards. Refers also to future trends in HV testing and measuring technique. With numerous illustrations. It is the intent of this book to combine high-voltage (HV) engineering with HV testing technique and HV measuring technique. Based on long-term experience gained by the authors as lecturer and researcher as well as member in international organizations, such as IEC and CIGRE, the book will reflect the state of the art as well as the future trends in testing and diagnostics of HV equipment to ensure a reliable generation, transmission and distribution of electrical energy. The book is intended not only for experts but also for students in electrical engineering and high-voltage engineering.

  19. Optical measurement techniques - A push for digitization

    Science.gov (United States)

    Kulkarni, Rishikesh; Rastogi, Pramod

    2016-12-01

    Over the years, optical measurement techniques have been the problem-solving backbone of many engineering applications such as nondestructive testing of materials, measurement of various material properties, structural analysis and experimental mechanics [1-3]. Probably the most important advantage associated with any optical measurement system over other systems is its non-contact type of measurement capability. Apart from their non-contact nature, the optical measurement systems are capable of providing full-field measurements at scales ranging from milli-meters to nano-meters.

  20. Review of air flow measurement techniques

    Energy Technology Data Exchange (ETDEWEB)

    McWilliams, Jennifer

    2002-12-01

    Airflow measurement techniques are necessary to determine the most basic of indoor air quality questions: ''Is there enough fresh air to provide a healthy environment for the occupants of the building?'' This paper outlines airflow measurement techniques, but it does not make recommendations for techniques that should be used. The airflows that will be discussed are those within a room or zone, those between rooms or zones, such as through doorways (open or closed) or passive vents, those between the building and outdoors, and those through mechanical air distribution systems. Techniques that are highlighted include particle streak velocimetry, hot wire anemometry, fan pressurization (measuring flow at a given pressure), tracer gas, acoustic methods for leak size determination, the Delta Q test to determine duct leakage flows, and flow hood measurements. Because tracer gas techniques are widely used to measure airflow, this topic is broken down into sections as follows: decay, pulse injection, constant injection, constant concentration, passive sampling, and single and multiple gas measurements for multiple zones.

  1. Measurement Uncertainties in Science and Technology

    CERN Document Server

    Grabe, Michael

    2005-01-01

    At the turn of the 19th century, Carl Friedrich Gauß founded error calculus by predicting the then unknown position of the planet Ceres. Ever since, error calculus has occupied a place at the heart of science. In this book, Grabe illustrates the breakdown of traditional error calculus in the face of modern measurement techniques. Revising Gauß’ error calculus ab initio, he treats random and unknown systematic errors on an equal footing from the outset. Furthermore, Grabe also proposes what may be called well defined measuring conditions, a prerequisite for defining confidence intervals that are consistent with basic statistical concepts. The resulting measurement uncertainties are as robust and reliable as required by modern-day science, engineering and technology.

  2. VALUATION TECHNIQUES USED IN FAIR VALUE MEASUREMENT

    OpenAIRE

    Cristina-Aurora, BUNEA-BONTAS

    2013-01-01

    Valuation of assets and liabilities involves significant judgements and estimates, especially when fair value measurement is required. Currently, IFRS 13 Fair Value Measurement offers a single and more comprehensive source of guidance that is applied to almost all fair value estimates. When measuring fair value of fixed assets, intangible assets, specified financial assets or liabilities, different valuation techniques may be used: the market approach, the cost approach and the income appr...

  3. A review on creatinine measurement techniques.

    Science.gov (United States)

    Mohabbati-Kalejahi, Elham; Azimirad, Vahid; Bahrami, Manouchehr; Ganbari, Ahmad

    2012-08-15

    This paper reviews the entire recent global tendency for creatinine measurement. Creatinine biosensors involve complex relationships between biology and micro-mechatronics to which the blood is subjected. Comparison between new and old methods shows that new techniques (e.g. Molecular Imprinted Polymers based algorithms) are better than old methods (e.g. Elisa) in terms of stability and linear range. All methods and their details for serum, plasma, urine and blood samples are surveyed. They are categorized into five main algorithms: optical, electrochemical, impedometrical, Ion Selective Field-Effect Transistor (ISFET) based technique and chromatography. Response time, detection limit, linear range and selectivity of reported sensors are discussed. Potentiometric measurement technique has the lowest response time of 4-10 s and the lowest detection limit of 0.28 nmol L(-1) belongs to chromatographic technique. Comparison between various techniques of measurements indicates that the best selectivity belongs to MIP based and chromatographic techniques. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. New optical technique for bulk magnetostriction measurement

    CERN Document Server

    Samata, H; Uchida, T; Abe, S

    2000-01-01

    A new optical technique was applied to the measurement of magnetostriction in bulk samples. This technique utilizes an optical fiber bundle, AC-modulated light and lock-in detection. Deformation of the sample is determined from the ratio of the incident and reflected light intensities. Noise due to the instability of the light source is eliminated by obtaining the ratio of the incident and reflected light intensities, and the noise caused in the detector circuit can be reduced by lock-in detection. The performance of this method was characterized with a series of measurements using a gold film and crystal disks of pure iron and nickel. This technique offers a resolution of 0.5 nm and is sensitive enough to measure magnetostriction as small as 5x10 sup - sup 7 in 1 mm thick samples.

  5. VALUATION TECHNIQUES USED IN FAIR VALUE MEASUREMENT

    Directory of Open Access Journals (Sweden)

    Cristina-Aurora, BUNEA-BONTAS

    2013-12-01

    Full Text Available Valuation of assets and liabilities involves significant judgements and estimates, especially when fair value measurement is required. Currently, IFRS 13 Fair Value Measurement offers a single and more comprehensive source of guidance that is applied to almost all fair value estimates. When measuring fair value of fixed assets, intangible assets, specified financial assets or liabilities, different valuation techniques may be used: the market approach, the cost approach and the income approach. This article reviews these techniques and points out that different valuation practices may provide different results depending on the item being fair valued and on the inputs used. Also it emphasizes that, in particular circumstances, there is the possibility that a certain technique may be more appropriate than other.

  6. Solar Cell Calibration and Measurement Techniques

    Science.gov (United States)

    Bailey, Sheila; Brinker, Dave; Curtis, Henry; Jenkins, Phillip; Scheiman, Dave

    2004-01-01

    The increasing complexity of space solar cells and the increasing international markets for both cells and arrays has resulted in workshops jointly sponsored by NASDA, ESA and NASA. These workshops are designed to obtain international agreement on standardized values for the AMO spectrum and constant, recommend laboratory measurement practices and establish a set of protocols for international comparison of laboratory measurements. A working draft of an ISO standard, WD15387, "Requirements for Measurement and Calibration Procedures for Space Solar Cells" was discussed with a focus on the scope of the document, a definition of primary standard cell, and required error analysis for all measurement techniques. Working groups addressed the issues of Air Mass Zero (AMO) solar constant and spectrum, laboratory measurement techniques, and te international round robin methodology. A summary is presented of the current state of each area and the formulation of the ISO document.

  7. A Survey of Advanced Microwave Frequency Measurement Techniques

    Directory of Open Access Journals (Sweden)

    Anand Swaroop Khare

    2012-06-01

    Full Text Available Microwaves are radio waves with wavelengths ranging from as long as one meter to as short as one millimeter, or equivalently, with frequencies between 300 MHz and 300 GHz. The science of photonics includes the generation, emission, modulation, signal processing, switching, transmission, amplification, detection and sensing of light. Microwave photonics has been introduced for achieving ultra broadband signal processing. Instantaneous Frequency Measurement (IFM receivers play an important role in electronic warfare. Technologies used for signal processing, include conventional direct Radio Frequency (RF techniques, digital techniques, intermediate frequency (IF techniques and photonic techniques. Direct RF techniques suffer an increased loss, high dispersion, and unwanted radiation problems in high frequencies. The systems that use traditional RF techniques can be bulky and often lack the agility required to perform advanced signal processing in rapidly changing environments. In this paper we discussed a survey of Microwave Frequency Measurement Techniques. The microwaves techniques are categorized based upon different approaches. This paper provides the major advancement in the Microwave Frequency MeasurementTechniques research; using these approaches the features and categories in the surveyed existing work.

  8. Comparison of cardiac output measurement techniques

    DEFF Research Database (Denmark)

    Espersen, K; Jensen, E W; Rosenborg, D;

    1995-01-01

    Simultaneously measured cardiac output obtained by thermodilution (TD), transcutaneous suprasternal ultrasonic Doppler (DOP), CO2-rebreathing (CR) and the direct Fick method (FI) were compared in eleven healthy subjects in a supine position (SU), a sitting position (SI), and during sitting exercise...... at a workload of 50 W (EX). The agreements between the techniques, two by two, were expressed as the bias calculated as the averaged differences between the techniques. Precision was expressed as the standard deviation of the bias. The overall agreement (bias +/- precision) between TD, DOP and CR respectively...... and CR, respectively, and TD were 2.5 +/- 2.2 and 2.6 +/- 1.6 l/min. The overall agreement between DOP and CR was 0.1 +/- 1.6 l/min. In conclusion, TD overestimated cardiac output compared to the other techniques and the poor agreement has to be taken into consideration especially in measures of low...

  9. Ionospheric Measurements Using Environmental Sampling Techniques

    Science.gov (United States)

    Bourdeau, R. E.; Jackson, J. E.; Kane, J. A.; Serbu, G. P.

    1960-01-01

    Two rockets were flown to peak altitudes of 220 km in September 1959 to test various methods planned for future measurements of ionization parameters in the ionosphere, exosphere, and interplanetary plasma. The experiments used techniques which sample the ambient environment in the immediate vicinity of the research vehicle. Direct methods were chosen since indirect propagation techniques do not provide the temperatures of charged particles, are insensitive to ion densities, and cannot measure local electron densities under all conditions. Very encouraging results have been obtained from a preliminary analysis of data provided by one of the two flights. A new rf probe technique was successfully used to determine the electron density profile. This was indicated by its agreement with the results of a companion cw propagation experiment, particularly when the probe data were corrected for the effects of the ion sheath which surrounds the vehicle. The characteristics of this sheath were determined directly in flight by an electric field meter which provided the sheath field, and by a Langmuir probe which measured the total potential across the sheath. The electron temperatures deduced from the Langmuir probe data are greater than the neutral gas temperatures previously measured for the same location and season, but these measurements possibly were taken under different atmospheric conditions. Ion densities were calculated from the ion trap data for several altitudes ranging from 130 to 210 km and were found to be within 20 percent of the measured electron densities.

  10. Techniques to Pass on: Technology and Euthanasia

    Science.gov (United States)

    Martin, Brian

    2010-01-01

    Proponents and opponents of euthanasia have argued passionately about whether it should be legalized. In Australia in the mid-1990s, following the world's first legal euthanasia deaths, Dr. Philip Nitschke initiated a different approach: a search for do-it-yourself technological means of dying with dignity. The Australian government has opposed…

  11. Techniques to Pass on: Technology and Euthanasia

    Science.gov (United States)

    Martin, Brian

    2010-01-01

    Proponents and opponents of euthanasia have argued passionately about whether it should be legalized. In Australia in the mid-1990s, following the world's first legal euthanasia deaths, Dr. Philip Nitschke initiated a different approach: a search for do-it-yourself technological means of dying with dignity. The Australian government has opposed…

  12. High-voltage test and measuring techniques

    CERN Document Server

    Hauschild, Wolfgang

    2014-01-01

    It is the intent of this book to combine high-voltage (HV) engineering with HV testing technique and HV measuring technique. Based on long-term experience gained by the authors as lecturer and researcher as well as member in international organizations, such as IEC and CIGRE, the book will reflect the state of the art as well as the future trends in testing and diagnostics of HV equipment to ensure a reliable generation, transmission and distribution of electrical energy. The book is intended not only for experts but also for students in electrical engineering and high-voltage engineering.

  13. Unsteady measurement techniques for turbomachinery flows

    Science.gov (United States)

    Jaffa, Nicholas Andrew

    Accurate unsteady measurements are required for studying the flows in high speed turbomachines, which rely on the interaction between rotating and stationary components. Using statistics of phase locked ensembles simplifies the problem, but accurate frequency response in the 10-100 kHz range significantly limits the applicable techniques. This research advances the state of the art for phase resolved measurement techniques using for high speed turbomachinery flows focusing on the following areas: development, validation, and uncertainty quantification. Four methods were developed and implemented: an unsteady total pressure probe, the multiple overheat hot-wire method, the slanted hot-wire method, and the phase peak yaw hot-wire method. These methods allow for the entire phase locked average flow field to be measured (temperature, pressure, and velocity components, swirl angle, etc.). No trusted reference measurement or representative canonical flow exists for comparison of the phase resolved quantities, making validation challenging. Five different validation exercises were performed to increase the confidence and explore the range of applicability. These exercises relied on checking for consistency with expected flow features, comparing independent measurements, and cross validation with CFD. The combined uncertainties for the measurements were quantified using uncertainty estimates from investigations into the elemental error sources. The frequency response uncertainty of constant temperature hot-wire system was investigated using a novel method of illuminating the wire with a laser pulse. The uncertainty analysis provided estimates for the uncertainty in the measurements as well as showing the sensitivity to various sources of error.

  14. Laser Feedback Technique for Precise Retardation Measurements

    Institute of Scientific and Technical Information of China (English)

    FEI Li-Gang; ZHANG Shu-Lian

    2006-01-01

    @@ A simple and precise retardation measurement based on laser feedback is demonstrated. The measurement principle is based on polarization flipping induced by optical feedback from an external birefringence cavity.The measured wave plate is located in the external cavity. When the length of the external cavity is tuned,the polarization states of laser will flip between two eigenstates, and the position of polarization flipping in one period of intensity modulation will vary with retardation of the wave plate. The duty ratio of two eigenstates is used to determine the retardation. Main advantages of the technique are that it is compact, low cost, fast and flexible. Especially, it is insensitive to a fluctuation of laser intensity and is suitable for on-line measurement. The experimental results have shown that the measurement uncertainty is better than 0.03° in the range 30°-150°.

  15. Pulsed thrust measurements using electromagnetic calibration techniques

    Energy Technology Data Exchange (ETDEWEB)

    Tang Haibin; Shi Chenbo; Zhang Xin' ai; Zhang Zun; Cheng Jiao [School of Astronautics, Beijing University of Aeronautics and Astronautics, Beijing 100191 (China)

    2011-03-15

    A thrust stand for accurately measuring impulse bits, which ranged from 10-1000 {mu}N s using a noncontact electromagnetic calibration technique is described. In particular, a permanent magnet structure was designed to produce a uniform magnetic field, and a multiturn coil was made to produce a calibration force less than 10 mN. The electromagnetic calibration force for pulsed thrust measurements was linear to the coil current and changed less than 2.5% when the distance between the coil and magnet changed 6 mm. A pulsed plasma thruster was first tested on the thrust stand, and afterward five single impulse bits were measured to give a 310 {mu}N s average impulse bit. Uncertainty of the measured impulse bit was analyzed to evaluate the quality of the measurement and was found to be 10 {mu}N s with 95% credibility.

  16. Techniques and technologies to maximize mucosal exposure

    NARCIS (Netherlands)

    Moons, L.M.; Gralnek, I.M.; Siersema, P.D.

    2015-01-01

    Performing high-quality colonoscopy is one of the important goals of gastroenterology practices and requires achieving a high level of bowel cleansing, performing good and safe polypectomy, and detecting all polyps present in the colon. This article summarizes currently available techniques and tech

  17. Techniques to measure testosterone in the elderly.

    Science.gov (United States)

    Klee, G G; Heser, D W

    2000-01-01

    In today's clinical and research settings, there is an unfortunate lack of consistency for the term "measuring testosterone status." This term is often used to refer to a measure of biologic androgen activity rather than the specific measurement of the chemical concentration of the testosterone steroid molecule. Even the measurements of chemical concentrations show considerable methodologic differences. This is true for measurements in elderly men, as well as in other populations, including women. All of the current methods for measuring total testosterone have limitations, especially with regard to low concentrations. In addition, unresolved questions concerning the active form of the hormone preclude definitive determination of which form of testosterone and which other androgen hormones are best suited for measuring androgen activity. When measurement techniques are compared, the numbers correlate with each other but certainly do not represent the same value. There is a need for a consensus as to which forms of hormones should be measured to best assess androgen status, and there is a need to standardize the procedures used to measure these hormones.

  18. Seminar on Detectors and measurements techniques

    Energy Technology Data Exchange (ETDEWEB)

    Holm, E. (ed.) [Risoe National Lab., Roskilde (Denmark)

    2002-07-01

    A Nordic Seminar on detectors and radionuclide measurement techniques was held in Lund, Sweden, May 3-4, 2001. The objective was to highlight recent progress and problems for techniques to study environmental radioactivity. It covered the aspect of detector sample geometry's and methods for evaluation of gamma gamma pulse height distributions. Within the field of alpha-spectrometric techniques gridded ionisation chambers, semiconductor detectors and a general description for analysis of alpha-particle-spectra were presented. Recent development in mass spectrometric techniques, AMS (Accelerator Mass Spectrometry) and ICPMS (Inductively Coupled Plasma mass Spectrometry) for long-lived radionuclides was described. Principles for analysis of beta particle emitters, especially by liquid scintillation were presented. The seminar also covered radiochemistry such advantages and disadvantages between ion exchange, solvent extraction and extraction chromatography. The use of controlled laboratory conditions for discerning the dynamics of accumulation in organisms was demonstrated. Other techniques such as neutron activation were also shown to be useful analytical tool for certain long-lived radionuclides. The results of the intercalibration exercises within the Nordic countries showed the importance of such analytical quality control. (au)

  19. Surface Wear Measurement Using Optical Correlation Technique

    Science.gov (United States)

    Acinger, Kresimir

    1983-12-01

    The coherent optical correlation technique was applied for measuring the surface wear of a tappet (part of car engine), worn by friction with the camshaft. It was found that maximum correlation intensity decays exponentially with the number of wear cycles (i.e. camshaft revolutions). Tappets of the same make have an identical rate of correlation decay. Tappets of different makes have different rates of correlation decay which are in agreement with observed long term wear.

  20. Granulation techniques and technologies: recent progresses

    OpenAIRE

    Srinivasan Shanmugam

    2015-01-01

    Granulation, the process of particle enlargement by agglomeration technique, is one of the most significant unit operations in the production of pharmaceutical dosage forms, mostly tablets and capsules. Granulation process transforms fine powders into free-flowing, dust-free granules that are easy to compress. Nevertheless, granulation poses numerous challenges due to high quality requirement of the formed granules in terms of content uniformity and physicochemical proper...

  1. Single spin measurement using cellular automata techniques

    CERN Document Server

    Perez-Delgado, C A; Cory, D G; Mosca, M; Cappellaro, Paola; Cory, David G.; Mosca, Michele; Perez-Delgado, Carlos A.

    2006-01-01

    We propose an approach for single spin measurement. Our method uses techniques from the theory of quantum cellular automata to correlate a large amount of ancillary spins to the one to be measured. It has the distinct advantage of being efficient, and to a certain extent fault-tolerant. Under ideal conditions, it requires the application of only order of cube root of N steps (each requiring a constant number of rf pulses) to create a system of N correlated spins. It is also fairly robust against pulse errors, imperfect initial polarization of the ancilla spin system, and does not rely on entanglement. We study the scalability of our scheme through numerical simulation.

  2. Can Science and Technology Capacity be Measured?

    CERN Document Server

    Wagner, Caroline S; Dutta, Arindum

    2015-01-01

    The ability of a nation to participate in the global knowledge economy depends to some extent on its capacities in science and technology. In an effort to assess the capacity of different countries in science and technology, this article updates a classification scheme developed by RAND to measure science and technology capacity for 150 countries of the world.

  3. High resolution temperature measurement technique for measuring marine heat flow

    Institute of Scientific and Technical Information of China (English)

    QIN; YangYang; YANG; XiaoQiu; WU; BaoZhen; SUN; ZhaoHua; SHI; XiaoBin

    2013-01-01

    High resolution temperature measurement technique is one of the key techniques for measuring marine heat flow. Basing on Pt1000 platinum resistance which has the characteristics of high accuracy and good stability, we designed a bridge reversal excitation circuit for high resolution temperature measurement. And the deep ocean floor in-situ test results show that: (1) temperature deviation and peak-to-peak resolution of the first version circuit board (V1) are 1.960-1.990 mK and 0.980-0.995 m Kat 1.2-2.7°C, respectively; and temperature deviation and peak-to-peak resolution of the second circuit board (V2) are 2.260mK and 1.130 mK at 1.2-1.3°C, respectively; (2) During the 2012NSFC-IndOcean cruise, seafloor geothermal gradient at Ind2012HF03,-07 and-12 stations (water depth ranges from 3841 to 4541 m) were successfully measured, the values are 59.1,75.1 and 71.6°C/km, respectively. And the measurement errors of geothermal gradient at these three stations are less than 3.0% in terms of the peak-to-peak resolution. These indicate that the high resolution temperature measurement technique based on Pt1000 platinum resistance in this paper can be applied to marine heat flow measurement to obtain high precision geothermal parameters.

  4. Quality Measures for Improving Technology Trees

    Directory of Open Access Journals (Sweden)

    Teemu J. Heinimäki

    2015-01-01

    Full Text Available The quality of technology trees in digital games can be improved by adjusting their structural and quantitative properties. Therefore, there is a demand for recognizing and measuring such properties. Part of the process can be automated; there are properties measurable by computers, and analyses based on the results (and visualizations of them may help to produce significantly better technology trees, even practically without extra workload for humans. In this paper, we introduce useful technology tree properties and novel measuring features implemented into our software tool for manipulating technology trees.

  5. A DGT technique for plutonium bioavailability measurements.

    Science.gov (United States)

    Cusnir, Ruslan; Steinmann, Philipp; Bochud, François; Froidevaux, Pascal

    2014-09-16

    The toxicity of heavy metals in natural waters is strongly dependent on the local chemical environment. Assessing the bioavailability of radionuclides predicts the toxic effects to aquatic biota. The technique of diffusive gradients in thin films (DGT) is largely exploited for bioavailability measurements of trace metals in waters. However, it has not been applied for plutonium speciation measurements yet. This study investigates the use of DGT technique for plutonium bioavailability measurements in chemically different environments. We used a diffusion cell to determine the diffusion coefficients (D) of plutonium in polyacrylamide (PAM) gel and found D in the range of 2.06-2.29 × 10(-6) cm(2) s(-1). It ranged between 1.10 and 2.03 × 10(-6) cm(2) s(-1) in the presence of fulvic acid and in natural waters with low DOM. In the presence of 20 ppm of humic acid of an organic-rich soil, plutonium diffusion was hindered by a factor of 5, with a diffusion coefficient of 0.50 × 10(-6) cm(2) s(-1). We also tested commercially available DGT devices with Chelex resin for plutonium bioavailability measurements in laboratory conditions and the diffusion coefficients agreed with those from the diffusion cell experiments. These findings show that the DGT methodology can be used to investigate the bioaccumulation of the labile plutonium fraction in aquatic biota.

  6. Full-field wafer warpage measurement technique

    Science.gov (United States)

    Hsieh, H. L.; Lee, J. Y.; Huang, Y. G.; Liang, A. J.; Sun, B. Y.

    2017-06-01

    An innovative moiré technique for full-field wafer warpage measurement is proposed in this study. The wafer warpage measurement technique is developed based on moiré method, Talbot effect, scanning profiling method, stroboscopic, instantaneous phase-shift method, as well as four-step phase shift method, high resolution, high stability and full-field measurement capabilities can be easily achieved. According to the proposed full-field optical configuration, a laser beam is expanded into a collimated beam with a 2-inch diameter and projected onto the wafer surface. The beam is reflected by the wafer surface and forms a moiré fringe image after passing two circular gratings, which is then focused and captured on a CCD camera for computation. The corresponding moiré fringes reflected from the wafer surface are obtained by overlapping the images of the measuring grating and the reference grating. The moiré fringes will shift when wafer warpage occurs. The phase of the moiré fringes will change proportionally to the degree of warpage in the wafer, which can be measured by detecting variations in the phase shift of the moiré fringes in each detection points on the surface of the entire wafer. The phase shift variations of each detection points can be calculated via the instantaneous phase-shift method and the four-step phase-shift method. By adding up the phase shift variations of each detection points along the radii of the circular gratings, the warpage value and surface topography of the wafer can be obtained. Experiments show that the proposed method is capable of obtaining test results similar to that of a commercial sensor, as well as performing accurate measurements under high speed rotation of 1500rpm. As compared to current warpage measurement methods such as the beam optical method, confocal microscopy, laser interferometry, shadow moiré method, and structured light method, this proposed technique has the advantage of full-field measurement, high

  7. Innovation in surgical technology and techniques: Challenges and ethical issues.

    Science.gov (United States)

    Geiger, James D; Hirschl, Ronald B

    2015-06-01

    The pace of medical innovation continues to increase. The deployment of new technologies in surgery creates many ethical challenges including how to determine safety of the technology, what is the timing and process for deployment of a new technology, how are patients informed before undergoing a new technology or technique, how are the outcomes of a new technology evaluated and how are the responsibilities of individual patients and society at large balanced. Ethical considerations relevant to the implementation of ECMO and robotic surgery are explored to further discussion of how we can optimize the delicate balance between innovation and regulation.

  8. Thermoluminescence measurement technique using millisecond temperature pulses.

    Science.gov (United States)

    Manfred, Michael E; Gabriel, Nicholas T; Yukihara, Eduardo G; Talghader, Joseph J

    2010-06-01

    A measurement technique, pulsed thermoluminescence, is described which uses short thermal pulses to excite trapped carriers leading to radiative recombination. The pulses are obtained using microstructures with approximately 500 micros thermal time constants. The technique has many of the advantages of pulsed optically stimulated luminescence without the need for optical sources and filters to isolate the luminescent signal. Charge carrier traps in alpha-Al(2)O(3):C particles on microheaters were filled using 205 nm light. Temperature pulses of 10 and 50 ms were applied to the heaters and compared with a standard thermoluminescence curve taken at a ramp rate of 5 K s(-1). This produced curves of intensity verses temperature similar to standard thermoluminescence except shifted to higher temperatures. The luminescence of single particles was read multiple times with negligible loss of population. The lower limit of the duration of useful pulses appears to be limited by particle size and thermal contact between the particle and heater.

  9. Optical Parametric Technology for Methane Measurements

    Science.gov (United States)

    Dawsey, Martha; Numata, Kenji; Wu, Stewart; Riris, Haris

    2015-01-01

    Atmospheric methane (CH4) is the second most important anthropogenic greenhouse gas, with approximately 25 times the radiative forcing of carbon dioxide (CO2) per molecule. Yet, lack of understanding of the processes that control CH4 sources and sinks and its potential release from stored carbon reservoirs contributes significant uncertainty to our knowledge of the interaction between carbon cycle and climate change. At Goddard Space Flight Center (GSFC) we have been developing the technology needed to remotely measure CH4 from orbit. Our concept for a CH4 lidar is a nadir viewing instrument that uses the strong laser echoes from the Earth's surface to measure CH4. The instrument uses a tunable, narrow-frequency light source and photon-sensitive detector to make continuous measurements from orbit, in sunlight and darkness, at all latitudes and can be relatively immune to errors introduced by scattering from clouds and aerosols. Our measurement technique uses Integrated Path Differential Absorption (IPDA), which measures the absorption of laser pulses by a trace gas when tuned to a wavelength coincident with an absorption line. We have already demonstrated ground-based and airborne CH4 detection using Optical Parametric Amplifiers (OPA) at 1651 nm using a laser with approximately 10 microJ/pulse at 5kHz with a narrow linewidth. Next, we will upgrade our OPO system to add several more wavelengths in preparation for our September 2015 airborne campaign, and expect that these upgrades will enable CH4 measurements with 1% precision (10-20 ppb).

  10. Optical parametric technology for methane measurements

    Science.gov (United States)

    Dawsey, Martha; Numata, Kenji; Wu, Stewart; Riris, Haris

    2015-09-01

    Atmospheric methane (CH4) is the second most important anthropogenic greenhouse gas, with approximately 25 times the radiative forcing of carbon dioxide (CO2) per molecule. Yet, lack of understanding of the processes that control CH4 sources and sinks and its potential release from stored carbon reservoirs contributes significant uncertainty to our knowledge of the interaction between carbon cycle and climate change. At Goddard Space Flight Center (GSFC) we have been developing the technology needed to remotely measure CH4 from orbit. Our concept for a CH4 lidar is a nadir viewing instrument that uses the strong laser echoes from the Earth's surface to measure CH4. The instrument uses a tunable, narrow-frequency light source and photon-sensitive detector to make continuous measurements from orbit, in sunlight and darkness, at all latitudes and can be relatively immune to errors introduced by scattering from clouds and aerosols. Our measurement technique uses Integrated Path Differential Absorption (IPDA), which measures the absorption of laser pulses by a trace gas when tuned to a wavelength coincident with an absorption line. We have already demonstrated ground-based and airborne CH4 detection using Optical Parametric Amplifiers (OPA) at 1651 nm using a laser with approximately 10 μJ/pulse at 5kHz with a narrow linewidth. Next, we will upgrade our OPO system to add several more wavelengths in preparation for our September 2015 airborne campaign, and expect that these upgrades will enable CH4 measurements with 1% precision (10-20 ppb).

  11. Disruptive Innovation in Air Measurement Technology: Reality ...

    Science.gov (United States)

    This presentation is a big picture overview on the changing state of air measurement technology in the world, with a focus on the introduction of low-cost sensors into the market place. The presentation discusses how these new technologies may be a case study in disruptive innovation for the air pollution measurement field. The intended audience is primarily those with experience in air pollution measurement methods, but much of the talk is accessible to the general public. This is a keynote presentation on emerging air monitoring technology, to be provided at the AWMA measurements conference in March, 2016.

  12. Progress in automation, robotics and measuring techniques

    CERN Document Server

    Zieliński, Cezary; Kaliczyńska, Małgorzata

    2015-01-01

    This book presents recent progresses in control, automation, robotics, and measuring techniques. It includes contributions of top experts in the fields, focused on both theory and industrial practice. The particular chapters present a deep analysis of a specific technical problem which is in general followed by a numerical analysis and simulation, and results of an implementation for the solution of a real world problem. The presented theoretical results, practical solutions and guidelines will be useful for both researchers working in the area of engineering sciences and for practitioners solving industrial problems.    .

  13. 4. Workshop - Measurement techniques of stationary and transient multiphase flow

    Energy Technology Data Exchange (ETDEWEB)

    Prasser, H.M. (ed.)

    2001-05-01

    In November 2000, the 4th Workshop on Measurement Techniques for Stationary and Transient Multiphase Flows took place in Rossendorf. Three previous workshops of this series were national meetings; this time participants from different countries took part. The programme comprised 14 oral presentations, 9 of which are included in these proceedings in full length. A special highlight of the meeting was the main lecture ''Ultrasonic doppler method for bubbly flow measurement'' of Professor Masanori Aritomi, Dr. Hiroshige Kikura and Dr. Yumiko Suzuki. The workshop again dealt with high-resolution phase distribution and phase velocity measurement techniques based on electrical conductivity, ultrasound, laser light and high-speed cinematography. A number of presentations were dedicated to the application of wire-mesh sensors developed by FZR for different applications used by the Technical Universities of Delft and Munich and the Tokyo Institute of Technology. (orig.)

  14. Uncertainty Analysis Technique for OMEGA Dante Measurements

    Energy Technology Data Exchange (ETDEWEB)

    May, M J; Widmann, K; Sorce, C; Park, H; Schneider, M

    2010-05-07

    The Dante is an 18 channel X-ray filtered diode array which records the spectrally and temporally resolved radiation flux from various targets (e.g. hohlraums, etc.) at X-ray energies between 50 eV to 10 keV. It is a main diagnostics installed on the OMEGA laser facility at the Laboratory for Laser Energetics, University of Rochester. The absolute flux is determined from the photometric calibration of the X-ray diodes, filters and mirrors and an unfold algorithm. Understanding the errors on this absolute measurement is critical for understanding hohlraum energetic physics. We present a new method for quantifying the uncertainties on the determined flux using a Monte-Carlo parameter variation technique. This technique combines the uncertainties in both the unfold algorithm and the error from the absolute calibration of each channel into a one sigma Gaussian error function. One thousand test voltage sets are created using these error functions and processed by the unfold algorithm to produce individual spectra and fluxes. Statistical methods are applied to the resultant set of fluxes to estimate error bars on the measurements.

  15. Alternative techniques for beam halo measurements

    CERN Document Server

    Welsch, CP; Burel, B; Lefèvre, T; Chapman, T; Pilon, MJ

    2006-01-01

    In future high intensity, high energy accelerators it must be ensured that particle losses are minimized, as activation of the vacuum chambers or other components makes maintenance and upgrade work time consuming and costly. It is imperative to have a clear understanding of the mechanisms that can lead to halo formation and to have the possibility to test available theoretical models with an adequate experimental setup. Measurements based on optical transition radiation (OTR) are a well-established technique for measurements of the transverse beam profile. However, in order to be suitable for halo measurements as well, the dynamic range of the final image acquisition system needs to be high, being able to cover at least five orders of magnitude in intensity changes. Here, the performance of a standard acquisition system as it is used in the CLIC test facility (CTF3) is compared to a step-by-step measurement with a small movable photo multiplier tube and an innovative camera system based on charge injection de...

  16. Research of Fuel Flow Measuring and Testing Technologies Based on Ultrasonic Technique%基于超声波技术的燃油流量测试技术研究

    Institute of Scientific and Technical Information of China (English)

    叶迎西; 刘建民; 姜文; 魏炜; 李春景

    2016-01-01

    为满足现代飞机燃油系统模拟试验燃油流量高精度、快速度的测量要求,针对涡轮流量计不能长期保持校准曲线和破坏管路系统的缺陷,提出了超声波测试技术。重点介绍了超声波系统的技术要求、主要功能、工作原理、工作模式和实际测量情况,并结合燃油系统试验进行了对比检验。结果表明:该测试方法满足飞机燃油试验需要,主要设备具有高可靠性、可控性和稳定性,可实现燃油系统的无损测试。%Considering the fact that turbo flowmeter fails to keep steady state for a long time after the calibra-tion and the pipeline system is easily damaged , the ultrasonic testing technique was proposed to meet the re-quirements of accurately and quickly measuring fuel flow rate in modern aircraft fuel test .The ultrasonic sys-tem’ s technical requirements , main functions , working principle , operation mode and the actual testing were expounded .Contrast test of the fuel system shows that , this testing technology can meet requirements of the fu-el flow test, and the main device has high reliability , controllability and stability in realizing the nondestructive measurement of the fuel system .

  17. Measuring the bias of technological change

    OpenAIRE

    Doraszelski, Ulrich; Jaumandreu, Jordi

    2014-01-01

    Technological change can increase the productivity of the various factors of production in equal terms or it can be biased towards a specific factor. We develop an estimator for production functions when productivity is multi-dimensional. We directly assess the bias of technological change by measuring, at the level of the individual firm, how much of it is factor neutral and how much is labor augmenting. Applying our estimator to panel data from Spain, we find that technological change is in...

  18. On Measuring Technological Possibilities by Hypervolumes

    DEFF Research Database (Denmark)

    Asmild, Mette; Hougaard, Jens Leth

    2016-01-01

    Measuring technological possibilities is a somewhat neglected topic in the productivity analysis literature. We discuss existing methods as well as an obvious alternative measure based on hypervolumes. We illustrate the use of a volume-based measure on an empirical case of demolition projects from...

  19. Measurement Science and Technology at 2013

    Science.gov (United States)

    Birch, David J. S.

    2013-01-01

    journal, but also by the readers who can continue to refer to MST knowing that only work of a high standard is published here. Finally I wish to thank the Institute of Physics Publishing team and the whole Editorial Board of Measurement Science and Technology. Their professionalism, expertise and dedication have, together with the fine work of authors and reviewers, led directly to the journal's impact factor (a measure of the average number of times recent papers are referenced by others) rising to its all-time high of 1.494. Impact factor is often taken as an indication of the quality and relevance of recently published research, and although as researchers we develop our own instinct for recognizing journals of high quality, it is gratifying as an Editor to see the data from an independent organization (Thomson ISI) agreeing with my own assessment. In research, as in commerce, competition raises quality and it is especially encouraging that our impact factor is now, for the first time, the highest in the sector of wide-ranging instrumentation and techniques. There simply remains for me to say thank you again for your contribution to Measurement Science and Technology in 2012, and wish you all the very best for a successful 2013! References [1] Adamczyk K et al 2012 Measuring protein dynamics with ultrafast two-dimensional infrared spectroscopy Meas. Sci. Technol. 23 062001 [2] Okubo S and Tanaka H K M 2012 Imaging the density profile of a volcano interior with cosmic-ray muon radiography combined with classical gravimetry Meas. Sci. Technol. 23 042001

  20. Erosive Burning Study Utilizing Ultrasonic Measurement Techniques

    Science.gov (United States)

    Furfaro, James A.

    2003-01-01

    A 6-segment subscale motor was developed to generate a range of internal environments from which multiple propellants could be characterized for erosive burning. The motor test bed was designed to provide a high Mach number, high mass flux environment. Propellant regression rates were monitored for each segment utilizing ultrasonic measurement techniques. These data were obtained for three propellants RSRM, ETM- 03, and Castor@ IVA, which span two propellant types, PBAN (polybutadiene acrylonitrile) and HTPB (hydroxyl terminated polybutadiene). The characterization of these propellants indicates a remarkably similar erosive burning response to the induced flow environment. Propellant burnrates for each type had a conventional response with respect to pressure up to a bulk flow velocity threshold. Each propellant, however, had a unique threshold at which it would experience an increase in observed propellant burn rate. Above the observed threshold each propellant again demonstrated a similar enhanced burn rate response corresponding to the local flow environment.

  1. Remote measurement of corrosion using ultrasonic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, K.M.; Porter, A.M.

    1995-02-01

    Supercritical water oxidation (SCWO) technology has the potential of meeting the US Department of Energy`s treatment requirements for mixed radioactive waste. A major technical constraint of the SCWO process is corrosion. Safe operation of a pilot plant requires monitoring of the corrosion rate of the materials of construction. A method is needed for measurement of the corrosion rate taking place during operation. One approach is to directly measure the change in wall thickness or growth of oxide layer at critical points in the SCWO process. In FY-93, a brief survey of the industry was performed to evaluate nondestructive evaluation (NDE) methods for remote corrosion monitoring in supercritical vessels. As a result of this survey, it was determined that ultrasonic testing (UT) methods would be the most cost-effective and suitable method of achieving this. Therefore, the objective for FY-94 was to prove the feasibility of using UT to monitor corrosion of supercritical vessels remotely during operation without removal of the insulation.

  2. Noble Gas Measurement and Analysis Technique for Monitoring Reprocessing Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Charlton, William S [Univ. of California, Berkeley, CA (United States)

    1999-09-01

    An environmental monitoring technique using analysis of stable noble gas isotopic ratios on-stack at a reprocessing facility was developed. This technique integrates existing technologies to strengthen safeguards at reprocessing facilities. The isotopic ratios are measured using a mass spectrometry system and are compared to a database of calculated isotopic ratios using a Bayesian data analysis method to determine specific fuel parameters (e.g., burnup, fuel type, fuel age, etc.). These inferred parameters can be used by investigators to verify operator declarations. A user-friendly software application (named NOVA) was developed for the application of this technique. NOVA included a Visual Basic user interface coupling a Bayesian data analysis procedure to a reactor physics database (calculated using the Monteburns 3.01 code system). The integrated system (mass spectrometry, reactor modeling, and data analysis) was validated using on-stack measurements during the reprocessing of target fuel from a U.S. production reactor and gas samples from the processing of EBR-II fast breeder reactor driver fuel. These measurements led to an inferred burnup that matched the declared burnup with sufficient accuracy and consistency for most safeguards applications. The NOVA code was also tested using numerous light water reactor measurements from the literature. NOVA was capable of accurately determining spent fuel type, burnup, and fuel age for these experimental results. Work should continue to demonstrate the robustness of this system for production, power, and research reactor fuels.

  3. Donnan membrane technique (DMT) for anion measurement.

    Science.gov (United States)

    Vega, Flora Alonso; Weng, Liping; Temminghoff, Erwin J M; Van Riemsdijk, Willem H

    2010-04-01

    Donnan membrane technique (DMT) is developed and tested for determination of free anion concentrations. Time needed to reach the Donnan membrane equilibrium depends on type of ions and the background. The Donnan membrane equilibrium is reached in 1 day for Cl(-), 1-2 days for NO(3)(-), 1-4 days for SO(4)(2-) and SeO(4)(2-), and 1-14 days for H(2)PO(4)(-) in a background of 2-200 mM KCl or K(2)SO(4). The strongest effect of ionic strength on equilibrium time is found for H(2)PO(4)(-), followed by SO(4)(2-) and SeO(4)(2-), and then by Cl(-) and NO(3)(-). The negatively charged organic particles of fulvic and humic acids do not pass the membrane. Two approaches for the measurement of different anion species of the same element, such as SeO(4)(2-) and HSeO(3)(-), using DMT are proposed and tested. These two approaches are based on transport kinetics or response to ionic strength difference. A transport model that was developed previously for cation DMT is applied in this work to analyze the rate-limiting step in the anion DMT. In the absence of mobile/labile complexes, transport tends to be controlled by diffusion in solution at a low ionic strength, whereas at a higher ionic strength, diffusion in the membrane starts to control the transport.

  4. Application of Sensing Techniques to Cellular Force Measurement

    Directory of Open Access Journals (Sweden)

    James H.-C. Wang

    2010-11-01

    Full Text Available Cell traction forces (CTFs are the forces produced by cells and exerted on extracellular matrix or an underlying substrate. CTFs function to maintain cell shape, enable cell migration, and generate and detect mechanical signals. As such, they play a vital role in many fundamental biological processes, including angiogenesis, inflammation, and wound healing. Therefore, a close examination of CTFs can enable better understanding of the cellular and molecular mechanisms of such processes. To this end, various force-sensing techniques for CTF measurement have been developed over the years. This article will provide a concise review of these sensing techniques and comment on the needs for improved force-sensing technologies for cell mechanics and biology research.

  5. Electromagnetic techniques for industrial plant process measurements and quality control

    Energy Technology Data Exchange (ETDEWEB)

    Bramanti, M. (Consiglio Nazionale delle Ricerche, Pisa (Italy). Ist. di Elaborazione della Informazione)

    1992-04-01

    In recent years, new real time non-destructive measuring techniques have been developed based on the use of miniaturized components capable of generating, amplifying and elaborating microwave signals (within the range of tenths of a volt and hundreds of milliamps). All these techniques for the measurement of typical process parameters or the non-destructive testing of materials are based on the interaction of radiation with the material or system under examination and make use of the most modern types of data acquisition technology. This article surveys the sensors and measuring instruments which make use of electromagnetic radiation to acquire information concerning the properties of an examined material or system based on their interactions with electromagnetic fields. A few applications are illustrated, e.g., the measurement of unburnt coal in power plant fly ash, the measurement of the quantity of solid particles present in fluidized beds and the verification of the properties of dielectric materials. In each case, the optimum degree of resolution of these devices is made evident.

  6. Cognitive Heterogeneous Reconfigurable Optical Networks (CHRON): Enabling Technologies and Techniques

    DEFF Research Database (Denmark)

    Tafur Monroy, Idelfonso; Zibar, Darko; Guerrero Gonzalez, Neil;

    2011-01-01

    We present the approach of cognition applied to heterogeneous optical networks developed in the framework of the EU project CHRON: Cognitive Heterogeneous Reconfigurable Optical Network. We introduce and discuss in particular the technologies and techniques that will enable a cognitive optical ne...

  7. Application of Data Collection Techniques by Human Performance Technology Practitioners

    Science.gov (United States)

    Duan, Minjing

    2011-01-01

    By content-analyzing 22 published cases from a variety of professional and academic books and journals, this study examines the status quo of human performance technology (HPT) practitioners' application of five major data collection techniques in their everyday work: questionnaire, interview, focus group, observation, and document collection. The…

  8. Basic phenomena utilised in aerosol particle measurement techniques; Hiukkasmittaustekniikoiden perusilmioet

    Energy Technology Data Exchange (ETDEWEB)

    Janka, K. [Dekati Oy, Tampere (Finland)

    2006-10-15

    The project deals with development of basic phenomena and mechanism utilised in aerosol particle measurement techniques. The areas under development are: particle-charging techniques, photoelectric charging, particle concentrating using virtual-impactor technique, and optical characterising techniques of particles. Results will be applied on detection techniques of bioaerosol attract, particle emission sensors for diesel exhaust gases, and widening the application areas of existing measurement techniques. (orig.)

  9. Advances in Measurement Technology at NIST's Physical Measurement Laboratory

    Science.gov (United States)

    Dehmer, Joseph

    2014-03-01

    The NIST mission is to promote U.S. innovation and industrial competitiveness by advancing measurement science, standards, and technology. The Physical Measurement Laboratory (PML) has responsibility for maintaining national standards for two dozen physical quantities needed for international trade; and, importantly, it carries out advanced research at the frontiers of measurement science to enable extending innovation into new realms and new markets. This talk will highlight advances being made across several sectors of technology; and it will describe how PML interacts with its many collaborators and clients in industry, government, and academe.

  10. Arts and technology - Mosaic new techniques and procedures

    Science.gov (United States)

    Papiu, G. A.; Suciu, N.

    2017-05-01

    The relationship between art and technique has been along the time one that is inseparable and systematic, artists appealing to various technologies, tools and practices that help them stimulate their imagination. Today there is a new category of artists, coming from a technical or scientific field, that are being 'trapped’ in this ‘game of art”. The mosaic, even if it is an old technique, responded to the social requirements and it evolved over time, being constantly related to aesthetic and artistic thinking, discoveries of science, assimilating permanent new techniques and technologies, diversifying its artistic forms of expression and methods of transposition. Not being bound any more to a religious institution, which was its birth place, today, she migrated to all public spaces. Works of art in public space have become today an active factor in reshaping the urban aesthetic landscape.

  11. Evolution and Future of Torque Measurement Technology

    Directory of Open Access Journals (Sweden)

    Dr. W. Krimmel

    2006-03-01

    Full Text Available The journey to the past of torque measurement technology begins in the 17th century. It takes us from the first incipiencies of torque measurement to the problem of the transfer of the measurement signal from a rotating shaft, which existed for several decades. This task was solved by the integration of high-precise digital measuring amplifiers in the torque sensors, which is expressed by broad application fields, today. The future will appertain to highly dynamic measuring sensors as well as to intelligent torque sensors, which are able to transmit their sensor-specific characteristics to evaluation devices.

  12. Spectroscopic Measurement Techniques for Aerospace Flows

    Science.gov (United States)

    Danehy, Paul M.; Bathel, Brett F.; Johansen, Craig T.; Cutler, Andrew D.; Hurley, Samantha

    2014-01-01

    The conditions that characterize aerospace flows are so varied, that a single diagnostic technique is not sufficient for its measurement. Fluid dynamists use knowledge of similarity to help categorize and focus on different flow conditions. For example, the Reynolds number represents the ratio of inertial to viscous forces in a flow. When the velocity scales, length scales, and gas density are large and the magnitude of the molecular viscosity is low, the Reynolds number becomes large. This corresponds to large scale vehicles (e.g Airbus A380), fast moving objects (e.g. artillery projectiles), vehicles in dense fluids (e.g. submarine in water), or flows with low dynamic viscosity (e.g. skydiver in air). In each of these cases, the inertial forces dominate viscous forces, and unsteady turbulent fluctuations in the flow variables are observed. In contrast, flows with small length scales (e.g. dispersion of micro-particles in a solid rocket nozzle), slow moving objects (e.g. micro aerial vehicles), flows with low density gases (e.g. atmospheric re-entry), or fluids with a large magnitude of viscosity (e.g. engine coolant flow), all have low Reynolds numbers. In these cases, viscous forces become very important and often the flows can be steady and laminar. The Mach number, which is the ratio of the velocity to the speed of sound in the medium, also helps to differentiate types of flows. At very low Mach numbers, acoustic waves travel much faster than the object, and the flow can be assumed to be incompressible (e.g. Cessna 172 aircraft). As the object speed approaches the speed of sound, the gas density can become variable (e.g. flow over wing of Learjet 85). When the object speed is higher than the speed of sound (Ma > 1), the presences of shock waves and other gas dynamic features can become important to the vehicle performance (e.g. SR-71 Blackbird). In the hypersonic flow regime (Ma > 5), large changes in temperature begin to affect flow properties, causing real

  13. Optical metrology techniques for dimensional stability measurements

    NARCIS (Netherlands)

    Ellis, Jonathan David

    2010-01-01

    This thesis work is optical metrology techniques to determine material stability. In addition to displacement interferometry, topics such as periodic nonlinearity, Fabry-Perot interferometry, refractometry, and laser stabilization are covered.

  14. Optical metrology techniques for dimensional stability measurements

    NARCIS (Netherlands)

    Ellis, Jonathan David

    2010-01-01

    This thesis work is optical metrology techniques to determine material stability. In addition to displacement interferometry, topics such as periodic nonlinearity, Fabry-Perot interferometry, refractometry, and laser stabilization are covered.

  15. Wheatstone bridge technique for magnetostriction measurements.

    Science.gov (United States)

    Sullivan, M

    1980-03-01

    A basic Wheatstone bridge, with additional electronic instrumentation, has been used in the measurement of magnetostriction. This method allows a resolution of approximately 10% on measurements of magnetostrictions less than 0.75 parts per million.

  16. Blood Glucose Measurement Using Bioimpedance Technique

    OpenAIRE

    2014-01-01

    Bioimpedance measurement is gaining importance in wide field of bioresearch and biomedical systems due to its noninvasive nature. Noninvasive measurement method is very important to decrease infection and physical injuries which result due to invasive measurement. This paper presents basic principle of bioimpedance along with its application for blood glucose analysis and effect of frequency on impedance measurement. Input from bioimpedance sensor is given to amplifier and signal conditioner ...

  17. Protocol of measurement techniques - Project colored solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    Schueler, A.; Chambrier, E. De; Roecker, Ch.; Scartezzini, J.-L.

    2004-08-15

    This illustrated annual report for the Swiss Federal Office of Energy (SFOE) takes a look at work done at the Swiss Federal Institute of Technology in Lausanne, Switzerland, on multi-layer, thin-film interference coatings for solar collector glazing. The correct combinations of refractive indices and film thickness are discussed. The authors state that corresponding multi-layered thin film stacks will have to be realised experimentally in a controlled and reproducible way. New thin film materials are to be tailored to exhibit optimised optical and ageing properties. The development of these coatings is to be based on various measurement techniques, such as spectro-photometry, measurements of total power throughput by means of a solar simulator, spectroscopic ellipsometry, scanning electron microscopy (SEM), X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS). The paper provides many examples of typical data and explains which film properties can be inferred from each method and thus describes both the function and purpose of the different measurement techniques.

  18. Technique for Measuring Hybrid Electronic Component Reliability

    Energy Technology Data Exchange (ETDEWEB)

    Green, C.C.; Hernandez, C.L.; Hosking, F.M.; Robinson, D.; Rutherford, B.; Uribe, F.

    1999-01-01

    Materials compatibility studies of aged, engineered materials and hardware are critical to understanding and predicting component reliability, particularly for systems with extended stockpile life requirements. Nondestructive testing capabilities for component reliability would significantly enhance lifetime predictions. For example, if the detection of crack propagation through a solder joint can be demonstrated, this technique could be used to develop baseline information to statistically determine solder joint lifelengths. This report will investigate high frequency signal response techniques for nondestructively evaluating the electrical behavior of thick film hybrid transmission lines.

  19. Advanced Failure Determination Measurement Techniques Used in Thermal Fatigue Life Testing of Electronic Packaging

    Science.gov (United States)

    Wallace, A. P.; Cornford, S. L.; Gross, M. A.

    1996-01-01

    Thermal fatigue life testing of various electronic packaging technologies is being performed by the Reliability Technology Group at the Jet Propulsion Laboratory. These testing efforts are in progress to improve uderstanding of the reliability issues associated with low volume packaging technologies for space applications and to develop qualification and acceptance approaches for these technologies. The work described here outlines the electrical failure detection techniques used during testing by documenting the circuits and components used to make these measurements, the sensitivity of the measurements, and the applicability of each specific measurement.

  20. On the theory of SODAR measurement techniques

    DEFF Research Database (Denmark)

    Antoniou, I.; Ejsing Jørgensen, Hans; Bradley, S.

    2003-01-01

    The need for alternative means to measure the wind speed for wind energy purposes has increased with the increase of the size of wind turbines. The cost and the technical difficulties for performing wind speed measurements has also increased with the sizeof the wind turbines, since it is demanded...... of measuring both the wind speed distribution with height and the wind direction. At the same time the SODAR presents a number of serious drawbacks such asthe low number of measurements per time period, the dependence of the ability to measure on the atmospheric conditions and the difficulty of measuring...... that the wind speed has to be measured at the rotor centre of the turbine and the size of both the rotor and the hub height have grown following the increase in the size of the wind turbines. The SODAR (SOundDetection And Ranging) is an alternative to the use of cup anemometers and offers the possibility...

  1. NEEMO 21: Tools, Techniques, Technologies & Training for Science Exploration EVA

    Science.gov (United States)

    Graff, Trevor

    2016-01-01

    The 21st mission of the NASA Extreme Environment Mission Operations (NEEMO) was a highly integrated operational test and evaluation of tools, techniques, technologies, and training for science driven exploration during Extravehicular Activity (EVA).The 16-day mission was conducted from the Aquarius habitat, an underwater laboratory, off the coast of Key Largo, FL. The unique facility, authentic science objectives, and diverse skill-sets of the crew/team facilitate the planning and design for future space exploration.

  2. Spray drying technique: II. Current applications in pharmaceutical technology.

    Science.gov (United States)

    Sollohub, Krzysztof; Cal, Krzysztof

    2010-02-01

    This review presents current applications of spray drying in pharmaceutical technology. The topics discussed include the obtention of excipients and cospray dried composites, methods for increasing the aqueous solubility and bioavailability of active substances, and modified release profiles from spray-dried particles. This review also describes the use of the spray drying technique in the context of biological therapies, such as the spray drying of proteins, inhalable powders, and viable organisms, and the modification of the physical properties of dry plant extracts.

  3. Perspective of remote optical measurement techniques

    OpenAIRE

    Gregorio, Eduard; Rocadenbosch Burillo, Francisco

    2007-01-01

    This article presents an intercomparison between four different ROMTs: differential optical absorption spectroscopy (DOAS), differential absorption LIDAR (DIAL), Fourier transform infrared spectroscopy (FTIR), and tunable diode laser absorption spectroscopy (TDLAS). The main focus is on the TDLAS technique, where the main laser-diode typologies and modulation schemes, namely, wavelength modulation spectroscopy (WMS) and frequency modulation spectroscopy (FMS), are reviewed. At present, new pr...

  4. Donnan Membrane Technique (DMT) for Anion Measurement

    NARCIS (Netherlands)

    Alonso Vega, M.F.; Weng, L.P.; Temminghoff, E.J.M.; Riemsdijk, van W.H.

    2010-01-01

    Donnan membrane technique (DMT) is developed and tested for determination of free anion concentrations. Time needed to reach the Donnan membrane equilibrium depends on type of ions and the background. The Donnan membrane equilibrium is reached in 1 day for Cl-, 1-2 days for NO3-, 1-4 days for SO42-

  5. Review of measurement techniques for the neutron radiative-capture process

    Energy Technology Data Exchange (ETDEWEB)

    Poenitz, W.P.

    1981-07-01

    The experimental techniques applied in measurements of the neutron capture process are reviewed. The emphasis is on measurement techniques used in neutron capture cross section measurements. The activation technique applied mainly in earlier work has still its use in some cases, specifically for measurements of technologically important cross sections (/sup 238/U and /sup 232/Th) with high accuracy. Three major prompt neutron radioactive capture detection techniques have evolved: the total gamma radiation energy detection technique (mainly with large liquid scintillation detectors), the gamma-energy proportional detectors (with proportional counters or Moxon-Rae detectors), and the pulse-height weighting technique. These measurement techniques are generally applicable, however, shortcomings limit the achievable accuracy to a approx. = 5 to 15% uncertainty level.

  6. Advanced computer modeling techniques expand belt conveyor technology

    Energy Technology Data Exchange (ETDEWEB)

    Alspaugh, M.

    1998-07-01

    Increased mining production is continuing to challenge engineers and manufacturers to keep up. The pressure to produce larger and more versatile equipment is increasing. This paper will show some recent major projects in the belt conveyor industry that have pushed the limits of design and engineering technology. Also, it will discuss the systems engineering discipline and advanced computer modeling tools that have helped make these achievements possible. Several examples of technologically advanced designs will be reviewed. However, new technology can sometimes produce increased problems with equipment availability and reliability if not carefully developed. Computer modeling techniques that help one design larger equipment can also compound operational headaches if engineering processes and algorithms are not carefully analyzed every step of the way.

  7. Blood Glucose Measurement Using Bioimpedance Technique

    Directory of Open Access Journals (Sweden)

    D. K. Kamat

    2014-01-01

    Full Text Available Bioimpedance measurement is gaining importance in wide field of bioresearch and biomedical systems due to its noninvasive nature. Noninvasive measurement method is very important to decrease infection and physical injuries which result due to invasive measurement. This paper presents basic principle of bioimpedance along with its application for blood glucose analysis and effect of frequency on impedance measurement. Input from bioimpedance sensor is given to amplifier and signal conditioner AD5933. AD5933 is then interfaced with microcontroller LPC1768 using I2C bus for displaying reading on LCD. Results can also be stored in database using UART interface of LPC1768.

  8. A Wireless Fluid-Level Measurement Technique

    Science.gov (United States)

    Woodard, Stanley E.; Taylor, Bryant D.

    2006-01-01

    This paper presents the application of a recently developed wireless measurement acquisition system to fluid-level measurement. This type of fluid-level measurement system alleviates many shortcomings of fluid-level measurement methods currently being used, including limited applicability of any one fluid-level sensor design. Measurement acquisition shortcomings include the necessity for power to be supplied to each sensor and for the measurement to be extracted from each sensor via a physical connection to the sensor. Another shortcoming is existing measurement systems require that a data channel and signal conditioning electronics be dedicated to each sensor. Use of wires results in other shortcomings such as logistics needed to add or replace sensors, weight, potential for electrical arcing and wire degradations. The fluid level sensor design is a simple passive inductor-capacitor circuit that is not subject to mechanical failure that is possible when float and lever-arm systems are used. Methods are presented for using the sensor in caustic, acidic or cryogenic fluids. Oscillating magnetic fields are used to power the sensor. Once electrically excited, the sensor produces a magnetic field response. The response frequency corresponds to the amount to fluid within the capacitor s electric field. The sensor design can be modified for measuring the level of any fluid or fluent substance that can be stored in a non-conductive reservoir. The interrogation method for discerning changes in the sensor response frequency is also presented.

  9. A Simple Technique for High Resistance Measurement

    Science.gov (United States)

    Aguilar, Horacio Munguia; Landin, Ramon Ochoa

    2012-01-01

    A simple electronic system for the measurement of high values of resistance is shown. This system allows the measurement of resistance in the range of a few megohm up to 10[superscript 9] [omega]. We have used this system for the evaluation of CdS thin film resistance, but other practical uses in the basic physics laboratory are presented.…

  10. A Simple Technique for High Resistance Measurement

    Science.gov (United States)

    Aguilar, Horacio Munguia; Landin, Ramon Ochoa

    2012-01-01

    A simple electronic system for the measurement of high values of resistance is shown. This system allows the measurement of resistance in the range of a few megohm up to 10[superscript 9] [omega]. We have used this system for the evaluation of CdS thin film resistance, but other practical uses in the basic physics laboratory are presented.…

  11. SPEED ROLLER STAND MEASUREMENT SYSTEM CHECKING TECHNIQUE

    OpenAIRE

    Zybtsev, Y.; I. Marmut

    2011-01-01

    The study has shown that the accuracy of brakes checking by inertial stands depends upon the applied methods of measurement of braking parameters (stand slowing down, braking distance, brakes triggering time, current speed) as well as the methods of metrological checking of measuring system canals.

  12. A simple technique for individual picosecond laser pulse duration measurements

    Science.gov (United States)

    Smith, W. L.; Bechtel, J. H.

    1976-01-01

    We describe here a simple nonlinear optic technique for the measurement of the duration of individual picosecond pulses. The accuracy and relative simplicity of the technique increase with the number of pulses measured. An experimental test of the basis of the technique is described.

  13. Diagnostic techniques for measuring suprathermal electron dynamics in plasmas (invited).

    Science.gov (United States)

    Coda, S

    2008-10-01

    Plasmas, both in the laboratory and in space, are often not in thermodynamic equilibrium, and the plasma electron distribution function is accordingly non-Maxwellian. Suprathermal electron tails can be generated by external drives, such as rf waves and electric fields, or internal ones, such as instabilities and magnetic reconnection. The variety and importance of the phenomena in which suprathermal electrons play a significant role explains an enduring interest in diagnostic techniques to investigate their properties and dynamics. X-ray bremsstrahlung emission has been studied in hot magnetized plasmas for well over two decades, flanked progressively by electron-cyclotron emission in geometries favoring the high-energy end of the distribution function (high-field-side, vertical, oblique emission), by electron-cyclotron absorption, by spectroscopic techniques, and at lower temperatures, by Langmuir probes and electrostatic analyzers. Continuous progress in detector technology and in measurement and analysis techniques, increasingly sophisticated layouts (multichannel and tomographic systems, imaging geometries), and highly controlled suprathermal generation methods (e.g., perturbative rf modulation) have all been brought to bear in recent years on an increasingly detailed, although far from complete, understanding of suprathermal electron dynamics.

  14. A Curriculum for Teaching Information Technology Investigative Techniques for Auditors

    Directory of Open Access Journals (Sweden)

    Grover S. Kearns

    2006-12-01

    Full Text Available Recent prosecutions of highly publicized white-collar crimes combined with public outrage have resulted in heightened regulation of financial reporting and greater emphasis on systems of internal control. Because both white-collar and cybercrimes are usually perpetrated through computers, internal and external auditors’ knowledge of information technology (IT is now more vital than ever. However, preserving digital evidence and investigative techniques, which can be essential to fraud examinations, are not skills frequently taught in accounting programs and instruction in the use of computer assisted auditing tools and techniques – applications that might uncover fraudulent activity – is limited. Only a few university-level accounting classes provide instruction in IT investigative techniques. This paper explains why such a course would be beneficial to the program, the college, and the student. Additionally, it presents a proposed curriculum and suggests useful resources for the instructor and student.

  15. Torsional and Bending Vibration Measurement on Rotors Using Laser Technology

    Science.gov (United States)

    MILES, T. J.; LUCAS, M.; HALLIWELL, N. A.; ROTHBERG, S. J.

    1999-09-01

    Based on the principles of laser Doppler velocimetry, the laser torsional vibrometer (LTV) was developed for non-contact measurement of torsional oscillation of rotating shafts, offering significant advantages over conventional techniques. This paper describes comprehensive theory to account for the sensitivity of the LTV's measurements to shaft motion in all degrees of freedom. The optical geometry of the LTV offers inherent immunity to translational motion of the target shaft, either axial or radial. However, its measurements are sensitive to angular lateral vibration of the shaft. The significance of this sensitivity is compared with the instrument noise floor and typical torsional and lateral vibration levels. Optimum alignments of the instrument are then specified to ensure effective immunity to all lateral motion in typical applications. To overcome this problem more reliably, a new technique is proposed permitting unambiguous measurement of pure torsional vibration in situations where use of a single LTV demonstrates unacceptable sensitivity to angular lateral vibrations. Practical application of this technology is demonstrated with torsional vibration measurements from a diesel engine crankshaft. Simultaneously, previously unattained measurements of shaft bending vibration measurements are made. The first bending mode of the crankshaft was identified and its vibration amplitude and damping estimated. This application of laser vibrometry for non-contact measurements of shaft vibration represents a further step forward in the use of this technology for machinery diagnostics.

  16. Applications of Modern Analysis Techniques in Searching back Ancient Art Ceramic Technologies

    Directory of Open Access Journals (Sweden)

    Nguyen Quang Liem

    2011-12-01

    Full Text Available This report highlights the promising applications of modern analysis techniques such as Scanning Electron Microsopy, X-ray fluorescence, X-ray diffraction, Raman scattering spectroscopy, and thermal expansion measurement in searching back the ancient art ceramics technologies.

  17. Apparatus and techniques for measuring bedload

    Science.gov (United States)

    Hubbell, David Wellington

    1964-01-01

    The need for accurate determinations of the total sediment discharge of particles of bedload size has prompted this investigation of available and possible measuring apparatus and procedures. The accuracy of measurements of sediment discharge made with trap-type samplers is affected by the variability of sampler efficiency, by the oscillatory variation of bedload discharge, and by sampler placement. Equations that were developed for determining total discharge from measured bedioad discharge and measured suspended-sediment discharge are simplest if the bedload apparatus measures only the true bedload. Early bedload samplers are generally unsatisfactory. Recently developed or suggested apparatus include various improved samplers of the pressure-difference type, a pumping sampler, a magnetic sampler, acoustical instruments that measure the magnitude of the sound of particle collisions, an ultrasonic bedload sampler designed to measure and integrate electronically the concentration and velocity, and a tiltmeter designed to measure the total sediment discharge from the ground tilt that results from the passage of flow. All the pressure-difference samplers are improvements over early samplers, but none are void of the inherent shortcomings of trap-type apparatus; probably the Sphinx (Dutch) and VUV (Hungarian) samplers are the most satisfactory. The acoustical instruments are capable of measuring only the relative discharge. The ultrasonic sampler and the tiltmeter are not adequate without further development. Some new possible apparatus and means for measuring or aiding in measuring bedload discharge are small pit samplers, ultrasonic sounders, pressure transducers, and photography. A small pit sampler for measuring bedload discharge was designed to provide self-placement and portability ; however, its practicability and efficiency are undetermined. Exploratory films show that by using slowmotion photography the discharge of particles larger than about pea size can be

  18. Advanced Aerodynamic Measurement Technology (Technologies avancees de mesure aerodynamique)

    Science.gov (United States)

    1998-05-01

    19th AIAA Advanced Measurement and Ground Testing Technology Conference, New Orleans, LA, June 17- 20, 1996. 17 Hart , R.C., Balla, R.J. and Herring...Deutsche Forschungsanstalt für Luft- und Raumfahrt Linder Höhe, D-51147 Köln, Germany and F. Grisch, P. Bouchardy Office National d’Etudees et de...trpy) in Du Pont Chroma Clear, (5) Ru(trpy)/Zeolite in GP-197, (6) EuTTA in dope, (7) Ru(bpy) in Du Pont Chroma Clear, (8) Perylenedicarboximide in

  19. Chemonucleolysis technique. New oblique approach requires no measurements.

    Science.gov (United States)

    Romy, M

    1986-01-01

    The author describes a new technique for intradiscal therapy that eliminates the need for measurements. The new technique for entering the lumbar disk for discolysis from the oblique approach is described as simple, accurate and safe.

  20. Altertative trophy measuring techniques for African buffalo

    Directory of Open Access Journals (Sweden)

    S.E. Gandy

    2004-12-01

    Full Text Available The African buffalo is considered the classic African trophy. It is the choice of many hunters who will never go on to hunt any of the other dangerous game animals on the continent. A good trophy is perceived as that of a mature bull with a hardened boss and horn tips that lengthen into sharply pointed hooks. However, indications are that these are the bulls in their breeding prime and there is concern that the continued targeting of these individuals will negatively impact on the population dynamics of the herds, ultimately affecting the sustainability of buffalo hunting. As they age and become postreproductive, the horns broom down, reducing the trophy score under the current measurement systems. A new measuring system is needed that encourages hunters to target the older post-reproductive bulls, instead of those that are still breeding. A random sample of trophies was divided into broomed and non-broomed sub-samples. All key parameters that can be measured in the trophy were measured with a view to identifying the parameters that would allow broomed-down individuals to compete favourably with the non-broomed “classic trophy” in the primary measurement systems, those of Safari Club International and Rowland Ward. An index, created through dividing tip space by the mean of the two individual horn lengths proved to serve the purpose. This factor was then applied to the mean of the SCI and Rowland Ward measurements in the samples. These methods allowed broomed horns to score more points in the record books than non-broomed horns. Boss width and boss space are other possible measurement inclusions that could be considered.

  1. Measuring and Test Equipment through barcode technology

    Energy Technology Data Exchange (ETDEWEB)

    Crockett, J.D.; Carr, C.C.

    1993-06-01

    Over the past several years, the use, trace methodology, and documentation of Measuring and Test Equipment has become a major concern. Current regulations are forcing companies to develop new policies, providing use history and traceability of Measuring and Test Equipment. The US Department of Energy and Environmental Organizations are driving Westinghouse Hanford Company to comply with the more stringent environmental guidelines and recent modifications in Department of Energy Orders. This paper discusses how the Fast Flux Test Facility at Westinghouse Hanford Company overcame these obstacles by using a computerized system through barcode technology.

  2. Waste Measurement Techniques For Lean Companies

    Directory of Open Access Journals (Sweden)

    Maciej Pieńkowski

    2014-12-01

    Full Text Available The paper is dedicated to answer the problem of measuring waste in companies, which are implementing Lean Manufacturing concept. Lack of complex identification, quantification an visualization of waste significantly impedes Lean transformation efforts. This problem can be solved by a careful investigation of Muda, Muri and Mura, which represent the essence of waste in the Toyota Production System. Measuring them facilitates complete and permanent elimination of waste in processes. The paper introduces a suggestion of methodology, which should enable company to quantify and visualize waste at a shop floor level.

  3. Compact Models and Measurement Techniques for High-Speed Interconnects

    CERN Document Server

    Sharma, Rohit

    2012-01-01

    Compact Models and Measurement Techniques for High-Speed Interconnects provides detailed analysis of issues related to high-speed interconnects from the perspective of modeling approaches and measurement techniques. Particular focus is laid on the unified approach (variational method combined with the transverse transmission line technique) to develop efficient compact models for planar interconnects. This book will give a qualitative summary of the various reported modeling techniques and approaches and will help researchers and graduate students with deeper insights into interconnect models in particular and interconnect in general. Time domain and frequency domain measurement techniques and simulation methodology are also explained in this book.

  4. Radar Cross-section Measurement Techniques

    Directory of Open Access Journals (Sweden)

    V.G. Borkar

    2010-03-01

    Full Text Available Radar cross-section (RCS is an important study parameter for defence applications specially dealing with airborne weapon system. The RCS parameter guides the detection range for a target and is therefore studied to understand the effectiveness of a weapon system. It is not only important to understand the RCS characteristics of a target but also to look into the diagnostic mode of study where factors contributing to a particular RCS values are studied. This further opens up subject like RCS suppression and stealth. The paper discusses the RCS principle, control, and need of measurements. Classification of RCS in terms of popular usage is explained with detailed theory of RF imaging and inverse synthetic aperture radar (ISAR. The various types of RCS measurement ranges are explained with brief discussion on outdoor RCS measurement range. The RCS calibration plays a critical role in referencing the measurement to absolute values and has been described.The RCS facility at Reseach Centre Imarat, Hyderabad, is explained with some details of different activities that are carried out including RAM evaluation, scale model testing, and diagnostic imaging.Defence Science Journal, 2010, 60(2, pp.204-212, DOI:http://dx.doi.org/10.14429/dsj.60.341

  5. Techniques for measuring customers’ satisfaction in Banks

    Directory of Open Access Journals (Sweden)

    Elena Lidia MELNIC

    2016-07-01

    Full Text Available The major concern of banks today is to recover and maintain customer trust. Customers need to feel that banks are considering their best interests. Customers are seeking for easy and personalized information. They want to better understand their financial situation and to control it. They want to know both the benefits, as well as the risks. Clients want to work with banks that are concerned about them and about their personal goals. However, only an attractive offer of banks is not the key to success today if is not supported by a superior service culture, that can make notable differentiation in the market. Many banks all over the world are systematically measuring how well they treat customers, identifying the factors shaping satisfaction, and changing operations and marketing as a result. Wise banks measure customer satisfaction regularly because it is one key to customer retention.

  6. Techniques for measuring renal transit time

    Energy Technology Data Exchange (ETDEWEB)

    Russell, C.D. [Div. of Nuclear Medicine, Univ. of Alabama at Birmingham Medical Center, AL (United States)]|[Nuclear Medicine Service, V.A. Medical Center, Birmingham, AL (United States); Japanwalla, M. [Div. of Nuclear Medicine, Univ. of Alabama at Birmingham Medical Center, AL (United States)]|[Nuclear Medicine Service, V.A. Medical Center, Birmingham, AL (United States); Khan, S. [Div. of Nuclear Medicine, Univ. of Alabama at Birmingham Medical Center, AL (United States)]|[Nuclear Medicine Service, V.A. Medical Center, Birmingham, AL (United States); Scott, J.W. [Div. of Nuclear Medicine, Univ. of Alabama at Birmingham Medical Center, AL (United States)]|[Nuclear Medicine Service, V.A. Medical Center, Birmingham, AL (United States); Dubovsky, E.V. [Div. of Nuclear Medicine, Univ. of Alabama at Birmingham Medical Center, AL (United States)]|[Nuclear Medicine Service, V.A. Medical Center, Birmingham, AL (United States)

    1995-12-01

    A variety of techniques have been used for quantitative estimation of renal transit time. We compared different indices of transit time in a group of 30 patients having baseline and ACE inhibitor technetium-99m mercaptoacetyltriglycine (MAG{sub 3}) renography prior to arteriography: Peak time, mean transit time, and the ratio of background-subtracted counts at 20 min to those at 3 min. Each index was calculated from whole-kidney ROI, cortical ROI, and cortical factor (by factor analysis). The strongest correlations between angiographic percent of stenosis and transit time index were observed for the peak time (Spearman {rho}=0.469, n=53) and for the R20/3 (again {rho}=0.469, n=53) using the whole-kidney ROI and using only the baseline data without captopril. (Spearman`s {rho} is simply the correlation coefficient calculated from rank in list, which allows for nonlinear correlation.) Thus simple indices of transit time (whole-kidney peak time and R20/3) correlated as well with the observed pathology as did more complicated methods that required deconvolution, factor analysis, or selection of a cortical ROI. (orig./MG)

  7. Emerging Technologies and Techniques for Wide Area Radiological Survey and Remediation

    Energy Technology Data Exchange (ETDEWEB)

    Sutton, M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Zhao, P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-03-24

    Technologies to survey and decontaminate wide-area contamination and process the subsequent radioactive waste have been developed and implemented following the Chernobyl nuclear power plant release and the breach of a radiological source resulting in contamination in Goiania, Brazil. These civilian examples of radioactive material releases provided some of the first examples of urban radiological remediation. Many emerging technologies have recently been developed and demonstrated in Japan following the release of radioactive cesium isotopes (Cs-134 and Cs-137) from the Fukushima Dai-ichi nuclear power plant in 2011. Information on technologies reported by several Japanese government agencies, such as the Japan Atomic Energy Agency (JAEA), the Ministry of the Environment (MOE) and the National Institute for Environmental Science (NIES), together with academic institutions and industry are summarized and compared to recently developed, deployed and available technologies in the United States. The technologies and techniques presented in this report may be deployed in response to a wide area contamination event in the United States. In some cases, additional research and testing is needed to adequately validate the technology effectiveness over wide areas. Survey techniques can be deployed on the ground or from the air, allowing a range of coverage rates and sensitivities. Survey technologies also include those useful in measuring decontamination progress and mapping contamination. Decontamination technologies and techniques range from non-destructive (e.g., high pressure washing) and minimally destructive (plowing), to fully destructive (surface removal or demolition). Waste minimization techniques can greatly impact the long-term environmental consequences and cost following remediation efforts. Recommendations on technical improvements to address technology gaps are presented together with observations on remediation in Japan.

  8. Solar system exploration - Some thoughts on techniques and technologies

    Science.gov (United States)

    Bekey, Ivan

    1990-01-01

    Some techniques and technologies for proposed interplanetary missions are described. Methods for reducing the effect of zero gravity on humans during missions to Mars and the moon, and the need for launch vehicles with increased lift capability are discussed. The use of nuclear power, liquid oxygen from the moon, and helium 3 as propellants for spacecraft is examined. The development and capabilities of the Shuttle Z vehicle are considered. Attention is given to the Space Station Freedom and Energia. A launch vehicle concept which utilizes the Shuttle Z for a mission to Mars is presented.

  9. POF strain sensor using phase measurement techniques

    Science.gov (United States)

    Poisel, H.

    2008-03-01

    Polymer optical fiber (POF) elongation sensors have been proposed e.g. by Doering as a low-cost alternative to FBG (single mode Fiber Bragg Gratings) sensors targeting the lower sensitivity range. A recently recovered detection system known from laser distance meters turned out to be very sensitive while staying simple and thus offering low cost potential. The approach is based on measuring the phase shift of a (e.g. sinusoidally) modulated light signal guided in a POF under different tensions resulting in different transit times and thus different phase shifts.

  10. Landmine Detection Technologies to TraceExplosive Vapour Detection Techniques

    Directory of Open Access Journals (Sweden)

    J. C. Kapoor

    2007-11-01

    Full Text Available Large quantity of explosive is manufactured worldwide for use in various types of ammunition,arms, and mines, and used in armed conflicts. During manufacturing and usage of the explosiveequipment, some of the explosive residues are released into the environment in the form ofcontaminated effluents, unburnt explosives fumes and vapours. Limited but uncontrolledcontinuous release of trace vapours also takes place when explosive-laden landmines are deployedin the field. One of the major technological challenges in post-war scenario worldwide is thedetection of landmines using these trace vapour signatures and neutralising them safely.  Differenttypes of explosives are utilised as the main charge in antipersonnel and antitank landmines. Inthis paper, an effort has been made to review the techniques so far available based on explosivevapour detection especially to detect the landmines. A comprehensive compilation of relevantinformation on the techniques is presented, and their maturity levels, shortcomings, and difficultiesfaced are highlighted.

  11. Technology development of fabrication techniques for advanced solar dynamic concentrators

    Science.gov (United States)

    Richter, Scott W.

    1991-01-01

    The objective of the advanced concentrator program is to develop the technology that will lead to lightweight, highly reflective, accurate, scaleable, and long lived space solar dynamic concentrators. The advanced concentrator program encompasses new and innovative concepts, fabrication techniques, materials selection, and simulated space environmental testing. Fabrication techniques include methods of fabricating the substrates and coating substrate surfaces to produce high quality optical surfaces, acceptable for further coating with vapor deposited optical films. The selected materials to obtain a high quality optical surface include microsheet glass and Eccocoat EP-3 epoxy, with DC-93-500 selected as a candidate silicone adhesive and levelizing layer. The following procedures are defined: cutting, cleaning, forming, and bonding microsheet glass. Procedures are also defined for surface cleaning, and EP-3 epoxy application. The results and analyses from atomic oxygen and thermal cycling tests are used to determine the effects of orbital conditions in a space environment.

  12. An appraisal of techniques and equipment for cutting force measurement

    Institute of Scientific and Technical Information of China (English)

    AUDY J.

    2006-01-01

    Current research focussed on the assessment of metal machining process parameters and on the development of adaptive control, shows that machine performance, work-piece and tool material selections, tool life, quality of machined surfaces,the geometry of cutting tool edges, and cutting conditions are closely related to the cutting forces. This information is of great interest to cutting tool manufactures and users alike. Over the years there have been significant developments and improvements in the equipment used to monitor such forces. In 1930 mechanical gauges were replaced by resistance strain gauges, and some 30 years later compact air gauge dynamometers were invented. Since this time intensive research has continued being directed towards developing new approaches to cutting force measurement. The Kistler Company, well-known manufacturer of acceleration and piezoelectrical dynamometers, has worked in this field for more than three decades, and developed very sensitive devices.While leading manufacturing research laboratories are often equipped with this technology, classical electrical strain gauges and other dynamometers of individual designs are still commonly used in industry. The present paper presents data obtained using different techniques of force measurement in metal machining processes. In particular, areas of uncertainties, illustrated through results concerning the turning process, are analysed, leading to an appraisal of the current status of these measurements and their significance.

  13. Tear film measurement by optical reflectometry technique.

    Science.gov (United States)

    Lu, Hui; Wang, Michael R; Wang, Jianhua; Shen, Meixiao

    2014-02-01

    Evaluation of tear film is performed by an optical reflectometer system with alignment guided by a galvanometer scanner. The reflectometer system utilizes optical fibers to deliver illumination light to the tear film and collect the film reflectance as a function of wavelength. Film thickness is determined by best fitting the reflectance-wavelength curve. The spectral reflectance acquisition time is 15 ms, fast enough for detecting film thickness changes. Fast beam alignment of 1 s is achieved by the galvanometer scanner. The reflectometer was first used to evaluate artificial tear film on a model eye with and without a contact lens. The film thickness and thinning rate have been successfully quantified with the minimum measured thickness of about 0.3 μm. Tear films in human eyes, with and without a contact lens, have also been evaluated. A high-contrast spectral reflectance signal from the precontact lens tear film is clearly observed, and the thinning dynamics have been easily recorded from 3.69 to 1.31 μm with lipid layer thickness variation in the range of 41 to 67 nm. The accuracy of the measurement is better than ±0.58% of the film thickness at an estimated tear film refractive index error of ±0.001. The fiber-based reflectometer system is compact and easy to handle.

  14. Techniques for transparent lattice measurement and correction

    Science.gov (United States)

    Cheng, Weixing; Li, Yongjun; Ha, Kiman

    2017-07-01

    A novel method has been successfully demonstrated at NSLS-II to characterize the lattice parameters with gated BPM turn-by-turn (TbT) capability. This method can be used at high current operation. Conventional lattice characterization and tuning are carried out at low current in dedicated machine studies which include beam-based measurement/correction of orbit, tune, dispersion, beta-beat, phase advance, coupling etc. At the NSLS-II storage ring, we observed lattice drifting during beam accumulation in user operation. Coupling and lifetime change while insertion device (ID) gaps are moved. With the new method, dynamical lattice correction is possible to achieve reliable and productive operations. A bunch-by-bunch feedback system excites a small fraction (∼1%) of bunches and gated BPMs are aligned to see those bunch motions. The gated TbT position data are used to characterize the lattice hence correction can be applied. As there are ∼1% of total charges disturbed for a short period of time (several ms), this method is transparent to general user operation. We demonstrated the effectiveness of these tools during high current user operation.

  15. Acoustic measuring techniques for suspended sediment

    Science.gov (United States)

    Gruber, P.; Felix, D.; Storti, G.; Lattuada, M.; Fleckenstein, P.; Deschwanden, F.

    2016-11-01

    Acoustic signals can be used in various ways for suspended sediment monitoring. One possibility which lends itself particularly well in the context of hydropower plants (HPPs), is to use installations for acoustic discharge measurement (ADM). Such installations already exist at waterways of many HPPs. Similar to certain turbidimeters, the attenuation of the forward scattered signal travelling through the water-sediment mixture is correlated with suspended sediment concentration (SSC). This correlation can be based on reference SSCs, e.g. from gravimetric analyses of bottle samples. Without the need of additional sensors and practically maintenance-free, this method is used successfully in the HPP Fieschertal to warn the HPP operator of high SSC to prevent excessive turbine abrasion. Acoustic methods and systems that allow for estimating both SSC and particle size distribution (PSD) are under development. The simultaneous determination of SSC and PSD is not possible using a single frequency. Therefore, multi-frequency approaches are investigated for generally scattered signals. When backscattered signals are used, a stronger frequency dependency can be exploited. However, the reliable simultaneous determination of particle size (and distribution) and concentration is still a major challenge due to a low signal-to-noise ratio and an ill- posed problem of estimating concentration and size from recorded signals. The optimal setup configuration (angles, frequencies) for such a system is not unique and further investigations are recommended.

  16. Ground-based intercomparison of two isoprene measurement techniques

    Directory of Open Access Journals (Sweden)

    E. Leibrock

    2003-01-01

    Full Text Available An informal intercomparison of two isoprene (C5H8 measurement techniques was carried out during Fall of 1998 at a field site located approximately 3 km west of Boulder, Colorado, USA. A new chemical ionization mass spectrometric technique (CIMS was compared to a well-established gas chromatographic technique (GC. The CIMS technique utilized benzene cation chemistry to ionize isoprene. The isoprene levels measured by the CIMS were often larger than those obtained with the GC. The results indicate that the CIMS technique suffered from an anthropogenic interference associated with air masses from the Denver, CO metropolitan area as well as an additional interference occurring in clean conditions. However, the CIMS technique is also demonstrated to be sensitive and fast. Especially after introduction of a tandem mass spectrometric technique, it is therefore a candidate for isoprene measurements in remote environments near isoprene sources.

  17. Comparing techniques for measuring corticosterone in tadpoles

    Institute of Scientific and Technical Information of China (English)

    Pablo BURRACO; Rosa ARRIBAS; Saurabh S KULKARNI; Daniel R BUCHHOLZ; Ivan GOMEZ-MESTRE

    2015-01-01

    Glucocorticoids play a key role in mediating stress responses in vertebrates. Corticosterone (CORT) is the main glu-cocorticoid produced in amphibians, birds, and reptiles, and regulates several metabolic functions. The most common methods for quantifying CORT are competitive binding immunoassays: radioimmunoassay (RIA) and enzyme immunoassay (EIA). RIA has been broadly used since the 1980’s but it requires radioactivity. Commercial EIA kits permit quantifying hormone levels without radioactivity although the requirement for a larger sample volume may be a strong limitation for measurements involving larval amphibians. Here we usedXenopus laevis tadpoles to compare the performance of three commonly used procedures for determination of CORT: RIA on a chloroform extract of whole-body homogenate, EIA on plasma, and EIA on supernatant of whole-body homogenate. We treated tadpoles with exogenous CORT at 0, 25, 50, and 100 nM. RIA could distinguish between 0 and 25 nM, and EIA on plasma between 0 and 50 nM, whereas whole-body homogenate EIA only detected significant differences between 0 and 100 nM. Each procedure presents advantages and disadvantages regarding sensitivity, the use of radioactivity, sample size, handling time, and economic cost. RIA is preferred when studying small-bodied animals from which blood samples cannot be obtained. When CORT level differences are intermediate and blood sampling is possible, EIA on plasma is a good non-radioactive alternative. EIA on whole-body homogenates may be useful to assess qualitative changes in CORT levels when considerable differences are expected. Finally, we discuss our findings in the context of previous studies on CORT in amphibians [Current Zoology 61 (5): 835–845, 2015].

  18. The Sine Method: An Alternative Height Measurement Technique

    Science.gov (United States)

    Don C. Bragg; Lee E. Frelich; Robert T. Leverett; Will Blozan; Dale J. Luthringer

    2011-01-01

    Height is one of the most important dimensions of trees, but few observers are fully aware of the consequences of the misapplication of conventional height measurement techniques. A new approach, the sine method, can improve height measurement by being less sensitive to the requirements of conventional techniques (similar triangles and the tangent method). We studied...

  19. Particle fluence measurements by activation technique for radiation damage studies

    CERN Document Server

    León-Florián, E; Furetta, C; Leroy, Claude

    1995-01-01

    High-level radiation environment can produce radiation damage in detectors and their associate electronic components. The establishment of a correlation between damage, irradiation level and absorbed dose requires a precise measurement of the fluence of particles causing the damage. The activation technique is frequently used for performing particle fluence measurements. A review of this technique is presented.

  20. Equipment for measuring radiation. Part 3. Technique of measuring radiation

    Energy Technology Data Exchange (ETDEWEB)

    Radwanowski, L.J.

    1979-01-01

    Difficulties are noted in measuring the effects of radiation because of the excessively low energy of the measured fields. In nature there are different magnetic-dynamic and magnetic-hydrodynamic generators which are sources of very low intensity which changes in time. The equipment of measurements is examined in the example of one of the generators, underground water current. The apparatus is described in detail for measuring the intensity of the electromagnetic SHF field. Under the underground water currents a change is observed in the intensity of the electromagnetic field. The possibilities are also examined of direct measurement of ultrasonic elastic fluctuations caused by the underground current, as well as the possibility of recording other physical fields (spontaneous polarization, soil temperature). A study was made of the effect of the underground water current on the occurrence of physical, chemical and biological processes: photochemical reactions, reactions of metal oxidation, Golomb effect (change in the rate of sedimentation of argillaceous particles in water under the influence of a biofield), change in air humidity and soil water content, change in intensity of the magnetic field, Hall effect, change in luminescence of certain organisms or the luminophore released by them. Basic plans are presented of certain measurement and recording devices.

  1. Techniques for measuring ammonia in fly ash, mortar, and concrete

    Energy Technology Data Exchange (ETDEWEB)

    Rathbone, R.F. [Kentucky Univ., Lexington, KY (United States). Center for Applied Energy Reseach; Majors, R.K. [Boral Material Technologies, Inc., San Antonio, TX (United States). Engineered Materials

    2003-12-01

    The presence of ammonia in fly ash that is to be used in mortar and concrete is of increasing concern in the U.S., mainly due to the installation of selective catalytic reduction (SCR) DeNOx systems. When the SCR catalyst is new, contamination of the fly ash with ammonia is generally not a concern. However, as the catalyst in the SCR ages and becomes less efficient, the ammonia slip increases and results in a greater amount of ammonium salt being precipitated on the fly ash. The increase in ammonia concentration is compounded by variability that can occur on a day-to-day basis. When marketing ammonia-laden fly ash for use in mortar and concrete it is imperative that the concentration of ammonia is known. However, there currently is no widely accepted or ''standard'' method for ammonia measurement in fly ash. This paper describes two methods that have been developed and used by the University of Kentucky Center for Applied Energy Research and Boral Material Technologies, Inc. One of the methods uses gas detection tubes and can provide an accurate determination within five to ten minutes. Thus it is suitable as a rapid field technique. The other method employs a gas-sensing electrode and requires a longer period of time to complete the measurement. However, this second method can also be used to determine the quantity of ammonia in fresh mortar and concrete. (orig.)

  2. MPPT Technique Based on Current and Temperature Measurements

    Directory of Open Access Journals (Sweden)

    Eduardo Moreira Vicente

    2015-01-01

    Full Text Available This paper presents a new maximum power point tracking (MPPT method based on the measurement of temperature and short-circuit current, in a simple and efficient approach. These measurements, which can precisely define the maximum power point (MPP, have not been used together in other existing techniques. The temperature is measured with a low cost sensor and the solar irradiance is estimated through the relationship of the measured short-circuit current and its reference. Fast tracking speed and stable steady-state operation are advantages of this technique, which presents higher performance when compared to other well-known techniques.

  3. Opto-thermal in-vivo skin hydration measurements - a comparison study of different measurement techniques

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, P; Singh, H; Imhof, R E [Faculty of ESBE, London South Bank University, 103 Borough Road, London SE1 0AA (United Kingdom); Ciortea, L I; Berg, E P [Biox Systems Ltd, 103 Borough Road, London SE1 0AA (United Kingdom); Cui, Y, E-mail: xiaop@lsbu.ac.u [Sunrise Systems Limited, Flint Bridge Business Centre, Ely Road, Waterbeach, Cambridge CB5 9QZ (United Kingdom)

    2010-03-01

    We compared five different skin hydration measurement techniques, namely OTTER, Fingerprint sensors, Corneometer, Nova, and Moisture Checker, in order to understand the correlations between different skin hydration measurement techniques and to understand the repeatability of each technique. The measurements are performed on different in-vivo skin sites from different volunteers and at different hydration levels. The repeatability of different techniques is achieved by measuring the same skin site repeatedly. The correlations between different skin hydration measurement techniques are achieved by plotting results from different techniques against each other. The different skin hydration levels are achieved through the recovery period after a skin immersive hydration.

  4. Performance of Personal Identification System Technique Using Iris Biometrics Technology

    Directory of Open Access Journals (Sweden)

    V.K. Narendira Kumar

    2013-04-01

    Full Text Available The Iris identification as one of the significant techniques of biometric identification systems s and iris recognition algorithm is described. Biometric technology advances intellectual properties are wanted by many unauthorized personnel. As a result many researchers have being searching ways for more secure authentication methods for the user access. Iris recognition uses iris patterns for personnel identification. The system steps are capturing iris patterns; determining the location of iris boundaries; converting the iris boundary to the stretched polar coordinate system; extracting iris code based on texture analysis. The system has been implemented and tested using dataset of number of samples of iris data with different contrast quality. The developed algorithm performs satisfactorily on the images, provides 93% accuracy. Experimental results show that the proposed method has an encouraging performance.

  5. Method for measuring the alignment between information technology strategic planning and actions of information technology governance

    National Research Council Canada - National Science Library

    Silva, Lúcio Melre da; Souza Neto, João

    2014-01-01

    The purpose of this research is to present a method for measuring the degree of alignment between Strategic Planning and Information Technology Management practices and Information Technology Governance...

  6. Method for Measuring the Alignment Between Information Technology Strategic Planning and Actions of Information Technology Governance

    National Research Council Canada - National Science Library

    Lúcio Melre da Silva; João Souza Neto

    2014-01-01

    The purpose of this research is to present a method for measuring the degree of alignment between Strategic Planning and Information Technology Management practices and Information Technology Governance...

  7. Companding technique for high dynamic range measurements using Gafchromic films

    Energy Technology Data Exchange (ETDEWEB)

    Van den Heuvel, Frank; Crijns, Wouter; Defraene, Gilles [Department of Experimental Radiotherapy, Catholic University of Leuven, Leuven, Belgium B-3000 (Belgium)

    2011-12-15

    Purpose: To introduce a methodology to perform dose measurements using Gafchromic films which can span several decades of dose levels. Methods: The technique is based on a rescaling approach using different films irradiated at different dose levels. This is combined with a registration protocol correcting positioning and scaling factors for each film. The methodology is validated using TLD's for out-of-field doses. Furthermore, two examples are provided using the technique to characterize small sized radiosurgery cones and compared with measurements made with a pinpoint chamber. Results: Excellent agreement with TLD, planning systems and measurement was found. The superior resolution of the film technique was apparent. Conclusions: The authors have introduced a new technique allowing users to quantify very low doses in conjunction with commissioning measurements. The use of film also provides 2D information on beam characteristics in high resolution measurements.

  8. Measuring Technology and Mechatronics Automation in Electrical Engineering

    CERN Document Server

    2012-01-01

    Measuring Technology and Mechatronics Automation in Electrical Engineering includes select presentations on measuring technology and mechatronics automation related to electrical engineering, originally presented during the International Conference on Measuring Technology and Mechanatronics Automation (ICMTMA2012). This Fourth ICMTMA, held at Sanya, China, offered a prestigious, international forum for scientists, engineers, and educators to present the state of the art of measuring technology and mechatronics automation research.

  9. Technique for Measuring Body Circumferences and Skinfold Thicknesses.

    Science.gov (United States)

    1984-08-01

    of the tape measure. Technique For ease and accuracy of measurement, male subjects ( persons being measured) should wear swim suits or shorts and female...are now touching the second costo -sternal joint (Figure 3a). There is usually a slight bulge or prominence on the sternum at this level. This

  10. Digital technique for the simultaneous measurement of velocity and temperature.

    Science.gov (United States)

    Keffer, J F; Budny, R S; Kawall, J G

    1978-09-01

    A computer-oriented, hot-wire anemometer technique for the simultaneous measurement of velocity and temperature in heated turbulent flows is described. This technique involves conversion of analogue anemometer voltage signals into digital forms and processing of these latter on a digital computer, in accordance with the anemometer response equations, to obtain instantaneous temperature and velocity. The technique was tested with a heated plane jet and found to be satisfactory.

  11. Full-field laser vibration measurement in NDT techniques

    Science.gov (United States)

    Yue, Kaiduan; Li, Zhongke; Yi, Yaxing; Zhang, Fei

    2008-12-01

    Research of Non Destructive Testing (NDT) methodology has developed rapidly in recent years[1][2]. But it is rarely used for small objects such as Micro-electronic Mechanics System. Due to the small size of the MEMS, the traditional method of contact measurement seriously affects the parameter of the object measured. So a high accuracy non-contact measurement is required for optimization of MEMS designs and improvement of its reliability[3][4]. With recent advances in photonics, electronics, and computer technology, a Non Destructive Testing (NDT) laser time average interferometry is proposed in the paper. Laser interferometry has the advantages of non-contact, high accuracy, full-field and fast speed, so it can be used to detect cracks in MEMS. A time average measurement method of digital speckle pattern interferometry is proposed to measure the vibration mode of the MEMS in the paper. According to the sudden change of amplitude of vibration mode, a crack can be measured. With the speckle average technology, high accuracy phase-shift, continuous phase scanning technology, combined with optical amplification technology, the resolution of the amplitude reaches 1nm, and the resolution of the crack reaches 5μm. The measurement system being full-field, the measuring speed of the measurement system can reach 512*512 points per one minute.

  12. A New Technique for Measuring the Heat Loss Coefficient

    DEFF Research Database (Denmark)

    Svendsen, Sv Aa Højgaard; Rose, Jørgen

    1996-01-01

    To measure the effect of linear cold bridges in building envelope constructions the guarded hot box technique is used. A new method based on a guarded hot plate technique has been proposed and investigated with respect to errors. The results are promising and further development of the method is ...

  13. Measurement techniques for radiological characterization of contaminated sites

    Energy Technology Data Exchange (ETDEWEB)

    Loos, M.

    1996-09-18

    Once the decision is taken to characterize a contaminated site, appropriate measurement techniques must be selected. The choice will depend on the available information, on the nature and extent of the contamination, as well as on available resources (staff and budget). Some techniques are described on the basis of examples of characterization projects (e.g. Olen area in Belgium).

  14. Optical Measurement Techniques for Rocket Engine Testing and Component Applications: Digital Image Correlation and Dynamic Photogrammetry

    Science.gov (United States)

    Gradl, Paul

    2016-01-01

    NASA Marshall Space Flight Center (MSFC) has been advancing dynamic optical measurement systems, primarily Digital Image Correlation, for extreme environment rocket engine test applications. The Digital Image Correlation (DIC) technology is used to track local and full field deformations, displacement vectors and local and global strain measurements. This technology has been evaluated at MSFC through lab testing to full scale hotfire engine testing of the J-2X Upper Stage engine at Stennis Space Center. It has been shown to provide reliable measurement data and has replaced many traditional measurement techniques for NASA applications. NASA and AMRDEC have recently signed agreements for NASA to train and transition the technology to applications for missile and helicopter testing. This presentation will provide an overview and progression of the technology, various testing applications at NASA MSFC, overview of Army-NASA test collaborations and application lessons learned about Digital Image Correlation.

  15. Effects of equipment and technique on peak flow measurements

    Directory of Open Access Journals (Sweden)

    O'Driscoll B Ronan

    2006-06-01

    Full Text Available Abstract Background Different lung function equipment and different respiratory manoeuvres may produce different Peak Expiratory Flow (PEF results. Although the PEF is the most common lung function test, there have been few studies of these effects and no previous study has evaluated both factors in a single group of patients. Methods We studied 36 subjects (PEF range 80–570 l/min. All patients recorded PEF measurements using a short rapid expiration following maximal inspiration (PEF technique or a forced maximal expiration to residual volume (FVC technique. Measurements were made using a Wright's peak flow meter, a turbine spirometer and a Fleisch pneumotachograph spirometer. Results The mean PEF was 8.7% higher when the PEF technique was used (compared with FVC technique, p Conclusion Peak flow measurements are affected by the instruction given and by the device and Peak Flow scale used. Patient management decisions should not be based on PEF measurement made on different instruments.

  16. Measuring elastic constants using non-contact ultrasonic techniques

    Science.gov (United States)

    Edwards, R. S.; Perry, R.; Cleanthous, D.; Backhouse, D. J.; Moore, I. J.; Clough, A. R.; Stone, D. I.

    2012-05-01

    The use of ultrasound for measuring elastic constants and phase transitions is well established. Standard measurements use piezoelectric transducers requiring couplant and contact with the sample. Recently, non-destructive testing (NDT) has seen an increase in the use of non-contact ultrasonic techniques, for example electromagnetic acoustic transducers (EMATs) and laser ultrasound, due to their many benefits. For measurements of single crystals over a range of temperatures non-contact techniques could also bring many benefits. These techniques do not require couplant, and hence do not suffer from breaking of the bond between transducer and sample during thermal cycling, and will potentially lead to a simpler and more adaptable measurement system with lower risk of sample damage. We present recent work adapting EMAT advances from NDT to measurements of single crystals at cryogenic temperatures and illustrate this with measurements of magnetic phase transitions in Gd64Sc36 using both contact and non-contact transducers. We discuss the measurement techniques implemented to overcome noise problems, and a digital pulse-echo-overlap technique, using data analysis in the frequency domain to measure the velocity.

  17. Measuring Diagnostic Stand for Experimental Researches in Technology Machining

    Directory of Open Access Journals (Sweden)

    A. E. Dreval'

    2014-01-01

    Full Text Available The paper reviews applied techniques, methods, and structure of the control and measuring means to conduct experimental and scientific researches of cutting processes. Existing research methods in cutting the metals are divided by features, such as essence of methods, the number of records of physical indicators, the number of studied factors, duration of tests. The groups of methods are briefly characterized.The chair "Tool Engineering and Technologies" of BMSTU developed and made a diagnostic stand of control and measurements for conducting research activities in the field of materials processing technology by cutting to define rational technological decisions, when machining, and carry out an analysis of efficiency and economic feasibility of made decisions. The diagnostic stand contains modern the electronic equipment. Record of measuring parameters is made in real time with a possibility for visual representation of read results and mathematical and statistical processing of measurement results. The stand can be used in research laboratories of machine-building enterprises, laboratories of higher education institutions, and other scientific divisions.The paper presents a justification that the stand is reasonable to use for the following: completion and choice of rational cutting modes, workability assessment of new constructional materials, technical and operational characteristics of the processed surfaces, and operational properties of the cutting tools of various producers, choice of optimum geometrical parameters of the cutting tools and brands of the lubricant cooling technological means, as well as the energy consumption for the chosen machining process. The stand allows us to make an assessment of wear resistance and tribology-technical characteristics of tool materials, as well as an accuracy, rigidity, vibration stability of machines, both new and being in operation.

  18. Error reduction techniques for measuring long synchrotron mirrors

    Energy Technology Data Exchange (ETDEWEB)

    Irick, S.

    1998-07-01

    Many instruments and techniques are used for measuring long mirror surfaces. A Fizeau interferometer may be used to measure mirrors much longer than the interferometer aperture size by using grazing incidence at the mirror surface and analyzing the light reflected from a flat end mirror. Advantages of this technique are data acquisition speed and use of a common instrument. Disadvantages are reduced sampling interval, uncertainty of tangential position, and sagittal/tangential aspect ratio other than unity. Also, deep aspheric surfaces cannot be measured on a Fizeau interferometer without a specially made fringe nulling holographic plate. Other scanning instruments have been developed for measuring height, slope, or curvature profiles of the surface, but lack accuracy for very long scans required for X-ray synchrotron mirrors. The Long Trace Profiler (LTP) was developed specifically for long x-ray mirror measurement, and still outperforms other instruments, especially for aspheres. Thus, this paper focuses on error reduction techniques for the LTP.

  19. An ultrasonic technique for measuring stress in fasteners

    Science.gov (United States)

    Stevens, K. J.; Day, P.; Byron, D.

    1999-12-01

    High temperature bolting alloys are extensively used in the thermal power generation industry as for example, reheat ESV and Governor valve studs. Remnant life assessment methodologies and plant maintenance procedures require the monitoring of the operational stress levels in these fasteners. Some conventional ultrasonic techniques require longitudinal wave measurements to be undertaken when the nut on the bolt is loosened and then re-tightened. Other techniques use a combination of shear waves and longitudinal waves. In this paper, the problems and pitfalls associated with various ultrasonic techniques for measuring stress in bolts, is discussed. An ultrasonic technique developed for measuring the stress in Durehete 1055 bolts is presented. Material from a textured rolled bar has been used as a test bed in the development work. The technique uses shear wave birefringence and compression waves at several frequencies to measure texture, fastener length and the average stress. The technique was developed by making ultrasonic measurements on bolts tensioned in universal testing machines and a hydraulic nut. The ultrasonic measurements of residual stress have been checked against strain gauge measurements. The Durehete bolts have a hollow cylinder geometry of restricted dimensions, which significantly alters compression and shear wave velocities from bulk values and introduces hoop stresses which can be measured by rotating the polarization of the shear wave probe. Modelling of the experimental results has been undertaken using theories for the elastic wave propagation through waveguides. The dispersion equations allow the velocity and length of the fastener to be measured ultrasonically in some situations where the length of the fastener can not be measured directly with a vernier caliper or micrometer and/or where it is undesirable to loosen nuts to take calibration readings of the shear and compression wave velocities.

  20. Measuring the strategic value of information technology investments

    Energy Technology Data Exchange (ETDEWEB)

    Conrad, K.W. [Boeing Computer Services Co., Richland, WA (United States)

    1994-08-01

    Value is often perceived differently by the proponents of new information technologies and those who allocate resources and define priorities. Such differences often become a roadblock to meeting true business needs. Project justifications regularly rely on calculated cost savings, which rarely measure the full benefit of new technologies. In fact, if cost savings provide a complete picture, then the organization is probably just automating routine clerical operations and has abandoned efforts that would provide significant strategic value. Strategic value is not limited to financial calculations, but includes quality, time and risk criteria. This paper describes approaches for measuring strategic value that can provide organizations with proven techniques to improve performance, reengineer processes, benchmark performance against other suppliers, identify outsourcing opportunities, or defend themselves from pressures to outsource. Many organizations respond to tightening budgets by cutting overhead. These measurement approaches can demonstrate how overhead is critical to organizational effectiveness and how cost savings can be found, instead, by measurably improving performance throughout the organization. Finally, the paper describes efforts underway within the Department of Energy and at the Hanford Site to implement the approaches described in this paper.

  1. High impulse voltage and current measurement techniques fundamentals, measuring instruments, measuring methods

    CERN Document Server

    Schon, Klaus

    2013-01-01

    Equipment to be installed in electric power-transmission and distribution systems must pass acceptance tests with standardized high-voltage or high-current test impulses which simulate the stress on the insulation caused by external lightning discharges and switching operations in the grid. High impulse voltages and currents are also used in many other fields of science and engineering for various applications. Therefore, precise impulse-measurement techniques are necessary, either to prevent an over- or understressing of the insulation or to guarantee the effectiveness and quality of the application. The book deals with: principal generator circuits for generating high-voltage and high-current impulses measuring systems and their calibration according to IEC 60060 and IEC 62475 methods of estimating uncertainties of measurement mathematical and experimental basis for characterizing the transfer behavior of spatially extended systems used for measuring fast transients. This book is intended for engineers and ...

  2. Subpixel Target Location Techniques for 3-D Coordinate Measuring System

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The close photogrammetric 3-D coordinate measurement is a new measuring technology in the fields of the coordinate measurement machine (CMM) in recent years. In this method, we usually place some targets on the measured object and take image of targets to determine the object coordinate. The subpixel location of target image plays an important role in high accuracy 3-D coordinate measuring procedure. In this paper, some subpixel location methods are reviewed and some factors which affect location precision are analyzed. Then we propose bilinear interpolation centroid algorithm. The experiments have shown this algorithm can improve accuracy of target centroid by increasing available pixels.

  3. NEEMO 21: Tools, Techniques, Technologies and Training for Science Exploration

    Science.gov (United States)

    Graff, T.; Young, K.; Coan, D.; Merselis, D.; Bellantuono, A.; Dougan, K.; Rodriguez-Lanetty, M.; Nedimyer, K.; Chappell, S.; Beaton, K.; Naids, A.; Hood, A.; Reagan, M.; Rampe, E.; Todd, W.; Poffenberger, J.; Garrison, D.

    2017-01-01

    The 21st mission of the National Aeronautics and Space Administration (NASA) Extreme Environment Mission Operations (NEEMO) was a highly integrated operational field test and evaluation of tools, techniques, technologies, and training for science driven exploration during extravehicular activity (EVA). The mission was conducted in July 2016 from the Aquarius habitat, an underwater laboratory, off the coast of Key Largo in the Florida Keys National Marine Sanctuary. An international crew of eight (comprised of NASA and ESA astronauts, engineers, medical personnel, and habitat technicians) lived and worked in and around Aquarius and its surrounding reef environment for 16 days. The integrated testing (both interior and exterior objectives) conducted from this unique facility continues to support current and future human space exploration endeavors. Expanding on the scientific and operational evaluations conducted during NEEMO 20, the 21st NEEMO mission further incorporated a diverse Science Team comprised of planetary geoscientists from the Astromaterials Research and Exploration Science (ARES/XI) Division from the Johnson Space Center, marine scientists from the Department of Biological Sciences at Florida International University (FIU) Integrative Marine Genomics and Symbiosis (IMaGeS) Lab, and conservationists from the Coral Restoration Foundation. The Science Team worked in close coordination with the long-standing EVA operations, planning, engineering, and research components of NEEMO in all aspects of mission planning, development, and execution.

  4. Genetic technologies to enhance the Sterile Insect Technique (SIT)

    Energy Technology Data Exchange (ETDEWEB)

    Alphey, Luke; Baker, Pam; Condon, George C.; Condon, Kirsty C.; Dafa' alla, Tarig H.; Fu, Guoliang; Jin, Li; Labbe, Genevieve; Morrison, Neil M.; Nimmo, Derric D.; O' Connell, Sinead; Phillips, Caroline E.; Plackett, Andrew; Scaife, Sarah; Woods, Alexander, E-mail: luke.alphey@zoo.ox.ac.u [Oxitec Ltd., Oxford (United Kingdom); Burton, Rosemary S.; Epton, Matthew J.; Gong, Peng [University of Oxford (United Kingdom). Dept. of Zoology

    2006-07-01

    The Sterile Insect Technique (SIT) has been used very successfully against range of pest insects, including various tephritid fruit flies, several moths and a small number of livestock pests. However, modern genetics could potentially provide several improvements that would increase the cost-effectiveness of SIT, and extend the range of suitable species. These include improved identification of released individuals by incorporation of a stable, heritable, genetic marker; built-in sex separation (genetic sexing); reduction of the hazard posed by non-irradiated accidental releases from mass-rearing facility (fail-safe); elimination of the need for sterilization by irradiation (genetic sterilization). We discuss applications of these methods and the state of the art, at the time of this meeting, in developing suitable strains. We have demonstrated, in several key pest species, that the required strains can be constructed by introducing a repressible dominant lethal genetic system, a method known as RIDL(trade mark). Based on field experience with Medfly, incorporation of a genetic sexing system into SIT programs for other tephritids could potentially provide a very significant improvement in cost-effectiveness. We have now been able to make efficient female-lethal strains for Medfly. One advantage of our approach is that it should be possible rapidly to extend this technology to other fruit fly species; indeed we have recently been able also to make genetic sexing strains of Medfly (Anastrepha ludens). (author)

  5. The Evolving Field of Wound Measurement Techniques: A Literature Review.

    Science.gov (United States)

    Khoo, Rachel; Jansen, Shirley

    2016-06-01

    Wound healing is a complex and multifactorial process that requires the involvement of a multidisciplinary approach. Methods of wound measurement have been developed and continually refined with the purpose of ensuring precision in wound measurement and documentation as the primary indicator of healing. This review aims to ascertain the efficacies of current wound area measurement techniques, and to highlight any perceived gaps in the literature so as to develop suggestions for future studies and practice. Med- line, PubMed, CliniKey, and CINAHL were searched using the terms "wound/ulcer measurement techniques," "wound assessment," "digi- tal planimetry," and "structured light." Articles between 2000 and 2014 were selected, and secondary searches were carried out by exam- ining the references of relevant articles. Only papers written in English were included. A universal, standardized method of wound as- sessment has not been established or proposed. At present, techniques range from the simple to the more complex - most of which have char- acteristics that allow for applicability in both rural and urban settings. Techniques covered are: ruler measurements, acetate tracings/contact planimetry, digital planimetry, and structured light devices. Conclu- sion. In reviewing the literature, the precision and reliability of digital planimetry over the more conventional methods of ruler measurements and acetate tracings are consistently demonstrated. The advent and utility of the laser or structured light approach, however, is promising, has only been analyzed by a few, and opens up the scope for further evaluation of this technique.

  6. Blower-door techniques for measuring interzonal leakage

    Energy Technology Data Exchange (ETDEWEB)

    Hult, Erin L.; Sherman, Max H.; Walker, Iain

    2013-01-01

    Abstract The standard blower door test methods, such as ASTM E779, describe how to use a single blower door to determine the total leakage of a single-zone structure such as a detached single-family home. There are no standard test methods for measuring interzonal leakage in a two-zone or multi-zone building envelope such as might be encountered in with an attached garage or in a multifamily building. Some practitioners have been using techniques that involve making multiple measurements with a single blower door as well as combined measurements using multiple blower doors. Even for just two zones there are dozens of combinations of one-door and two-door test protocols that could conceivably be used to determine the interzonal air tightness. We examined many of these two-zone configurations using both simulation and measured data to estimate the accuracy and precision of each technique for realistic measurement scenarios. We also considered the impact of taking measurements at a single pressure versus over multiple pressures. We compared the various techniques and evaluated them for specific uses. Some techniques work better in one leakage regime; some are more sensitive to wind and other noise; some are more suited to determining only a subset of the leakage values. This paper makes recommendations on which techniques to use or not use for various cases and provides data that could be used to develop future test methods.

  7. An intensity-monitoring technique for measuring ellipsometric transients

    NARCIS (Netherlands)

    Droog, J.M.M.; Bootsma, G.A.

    1979-01-01

    Intensity-monitoring techniques make possible the measurement of rapid changes in the ellipsometric parameters. Methods used hitherto have been suitable for measuring slight changes only and require prior knowledge of the Δ and Ψ values for the initial surface. It is shown that larger changes can al

  8. Design techniques for large scale linear measurement systems

    Energy Technology Data Exchange (ETDEWEB)

    Candy, J.V.

    1979-03-01

    Techniques to design measurement schemes for systems modeled by large scale linear time invariant systems, i.e., physical systems modeled by a large number (> 5) of ordinary differential equations, are described. The techniques are based on transforming the physical system model to a coordinate system facilitating the design and then transforming back to the original coordinates. An example of a three-stage, four-species, extraction column used in the reprocessing of spent nuclear fuel elements is presented. The basic ideas are briefly discussed in the case of noisy measurements. An example using a plutonium nitrate storage vessel (reprocessing) with measurement uncertainty is also presented.

  9. Volume Measurement in Solid Objects Using Artificial Vision Technique

    Science.gov (United States)

    Cordova-Fraga, T.; Martinez-Espinosa, J. C.; Bernal, J.; Huerta-Franco, R.; Sosa-Aquino, M.; Vargas-Luna, M.

    2004-09-01

    A simple system using artificial vision technique for measuring the volume of solid objects is described. The system is based on the acquisition of an image sequence of the object while it is rotating on an automated mechanism controlled by a PC. Volumes of different objects such as a sphere, a cylinder and also a carrot were measured. The proposed algorithm was developed in environment LabView 6.1. This technique can be very useful when it is applied to measure the human body for evaluating its body composition.

  10. Optical skin friction measurement technique in hypersonic wind tunnel

    Science.gov (United States)

    Chen, Xing; Yao, Dapeng; Wen, Shuai; Pan, Junjie

    2016-10-01

    Shear-sensitive liquid-crystal coatings (SSLCCs) have an optical characteristic that they are sensitive to the applied shear stress. Based on this, a novel technique is developed to measure the applied shear stress of the model surface regarding both its magnitude and direction in hypersonic flow. The system of optical skin friction measurement are built in China Academy of Aerospace Aerodynamics (CAAA). A series of experiments of hypersonic vehicle is performed in wind tunnel of CAAA. Global skin friction distribution of the model which shows complicated flow structures is discussed, and a brief mechanism analysis and an evaluation on optical measurement technique have been made.

  11. Measurement of thermophysical properties by a pulse-heating technique

    Institute of Scientific and Technical Information of China (English)

    Peng Xiao; Jingmin Dai; Qingwei Wang

    2007-01-01

    A technique is described for the dynamic measurement of selected thermophysical properties of electrically conducting solids in the temperature range from 1100 K to the melting point. Based on rapid resistive self-heating of the specimen from room temperature to any desired high temperature in several seconds by the passage of an electical current pulse through it, this technique measures the pertinent quantities such as current, voltage, randiance temperature, with sub-millisecond time resolution. The pulse-heating technique is applied to strip specimens. The radiance temperature is measured by high-speed pyrometry,normal spectral emissivity of the strips is measured by integrating sphere reflectometry. The normal spectral emissivity results are used to compute the true temperature of the specimens. The heat capacity,electrical resistivity, total hemispherical emissivity are evaluated in the temperature range from 1100 K to the melting point.

  12. Videogrammetric Model Deformation Measurement Technique for Wind Tunnel Applications

    Science.gov (United States)

    Barrows, Danny A.

    2006-01-01

    Videogrammetric measurement technique developments at NASA Langley were driven largely by the need to quantify model deformation at the National Transonic Facility (NTF). This paper summarizes recent wind tunnel applications and issues at the NTF and other NASA Langley facilities including the Transonic Dynamics Tunnel, 31-Inch Mach 10 Tunnel, 8-Ft high Temperature Tunnel, and the 20-Ft Vertical Spin Tunnel. In addition, several adaptations of wind tunnel techniques to non-wind tunnel applications are summarized. These applications include wing deformation measurements on vehicles in flight, determining aerodynamic loads based on optical elastic deformation measurements, measurements on ultra-lightweight and inflatable space structures, and the use of an object-to-image plane scaling technique to support NASA s Space Exploration program.

  13. Analytical techniques for thin films treatise on materials science and technology

    CERN Document Server

    Tu, K N

    1988-01-01

    Treatise on Materials Science and Technology, Volume 27: Analytical Techniques for Thin Films covers a set of analytical techniques developed for thin films and interfaces, all based on scattering and excitation phenomena and theories. The book discusses photon beam and X-ray techniques; electron beam techniques; and ion beam techniques. Materials scientists, materials engineers, chemical engineers, and physicists will find the book invaluable.

  14. A novel in-situ measuring technique for aspheric surface

    Science.gov (United States)

    Zhang, Chuan; Wang, Ping; Chen, Yaolong

    2011-11-01

    In this paper, a novel in-situ surface measuring technique for optical elements with aspheric surface is presented. It is a contact type probe, and can be used for measuring ground surfaces. The theory of this technique develops from coordinate measuring machine (CMM), and the measurement accuracy of this technique is depended on the accuracy of computer numerical controlled (CNC). By installing a special equipment with high accuracy measuring head in main spindle of CNC machine, and moving the probe along the path which is described by a mathematical aspheric expression precisely, we could get relative errors of sag height of any position in this path. With this technique, the repeat positioning error caused by traditional off-line measurement will be avoided. The author also has finished a special software with VC++ 6.0. With this software, the form error of ground work piece could be corrected rapidly. This software can calculate and handle the arrangement automatically with all parameters which are required to input in operation interface. In the correction stage, the software can analyze and process error data and generate a new NC program with corrected data for next grinding stage. After 2 or 3 times measuring and correction, the surface shape error of the aspheric optical element will be less than 1μm. The finished work piece has a very good surface finish and can be polished with high quality.

  15. Improved hand hygiene technique and compliance in healthcare workers using gaming technology.

    Science.gov (United States)

    Higgins, A; Hannan, M M

    2013-05-01

    In 2009, the World Health Organization recommended the use of a 'multi-faceted, multi-modal hand hygiene strategy' (Five Moments for Hand Hygiene) to improve hand hygiene compliance among healthcare workers. As part of this initiative, a training programme was implemented using an automated gaming technology training and audit tool to educate staff on hand hygiene technique in an acute healthcare setting. To determine whether using this automated training programme and audit tool as part of a multi-modal strategy would improve hand hygiene compliance and technique in an acute healthcare setting. A time-series quasi-experimental design was chosen to measure compliance with the Five Moments for Hand Hygiene and handwashing technique. The study was performed from November 2009 to April 2012. An adenosine triphosphate monitoring system was used to measure handwashing technique, and SureWash (Glanta Ltd, Dublin, Ireland), an automated auditing and training unit, was used to provide assistance with staff training and education. Hand hygiene technique and compliance improved significantly over the study period (P hand hygiene programme can encourage staff participation in learning, and ultimately improve hand hygiene compliance and technique in the acute healthcare setting. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  16. Assessing the measurement of airway resistance by the interrupter technique.

    Science.gov (United States)

    Zuriarrain Reyna, Yolanda; López Neyra, Alejandro; Sanz Santiago, Verónica; Almería Gil, Esmeralda; Villa Asensi, José Ramón

    2013-12-01

    Pulmonary function tests allow an objective assessment of the degree of bronchial obstruction in collaborative subjects. The measurement of airway resistance using passive methods is very helpful in non-collaborative subjects. The objective of this study was to assess the applicability of measuring airway resistance by the interrupter technique (Rint) in pediatric subjects, determining its reproducibility, reliability and accuracy versus other techniques to measure airway resistance. Cross-sectional study in healthy children and in children with an obstructive airway disease, all aged 2-18 years old. The Rint was measured using a portable device and results were compared to airway resistance measured by oscillometry and plethysmography. The reproducibility of measurements and the infuence of the different outcome measures (use of mask or mouthpiece, cheek support, or nose clip) were assessed. Valid measurements were obtained in 82.6% of 460 children (47.6% younger than 7 years old). Reproducibility was very good (ICC= 0.9412; p measurements obtained at separate time intervals (0.75 ± 0.3 versus 0.74 ± 0.28; p= 0.435). None of the factors indicated before had an effect on the reproducibility of measurements. Resistance values obtained by plethysmography and oscillometry were higher than those obtained using the Rint, with a positive correlation between them. The higher the degree of airway obstruction, the worse the correlation with plethysmography. The Rint measurement is a plausible and reproducible technique, and has an adequate correlation with the resistance measurements obtained using oscillometry or plethysmography, thus making it useful for non-collaborative patients. In patients with airway obstruction, this technique could underestimate resistance, so it would be a hurdle to use it to follow-up subjects with a moderate to severe obstructive disease or in bronchial challenge tests.

  17. Measurement of Thermal Expansion Coefficients with Holographic Technique

    Institute of Scientific and Technical Information of China (English)

    ZhifengZhang

    1995-01-01

    A simplified mathematical model was created for measurement of thermal expansion coefficients of thin sheet materials with holographic technique.Experimental set-ups corresponding to the mathematical model were designed and built for both tests above room temperature and at low temperatures.A fringe control technique was introduced for low temperature measurements to compensate rigid body movement,THin sheet specimens of silicon and aluminum alloy(7075) were tested with the developed technique.The tested results are in good agreement with reported data and thus verify the validity of the developed technique.The Thermal expansion coefficients of the tested materials ranged from 2.5×10-60C-1 to 23.6×10-6oC-1.

  18. Advanced manufacturing techniques for next generation power FET technology

    OpenAIRE

    2005-01-01

    The development and incorporation of an evaporated airbridge technology into an established power pHEMT device is described. Advantages of this technology over a conventional plated technology are discussed. Use of this technology has resulted in improvements to the process flow in terms of reduced complexity and cycle time. Improvements in uniformity and reduced feature size have enabled the use of an automated visual inspection capability to reliably differentiate good and bad die.

  19. Handbook of microwave component measurements with advanced VNA techniques

    CERN Document Server

    Dunsmore, Joel P

    2012-01-01

    This book provides state-of-the-art coverage for making measurements on RF and Microwave Components, both active and passive. A perfect reference for R&D and Test Engineers, with topics ranging from the best practices for basic measurements, to an in-depth analysis of errors, correction methods, and uncertainty analysis, this book provides everything you need to understand microwave measurements. With primary focus on active and passive measurements using a Vector Network Analyzer, these techniques and analysis are equally applicable to measurements made with Spectrum Analyzers or Noise Figure

  20. Measurement of fuel spray vaporisation by laser techniques

    Science.gov (United States)

    Yule, A. J.; Seng, C. A.; Felton, P. G.; Ungut, A.; Chigier, N. A.

    1980-01-01

    Comparison of fuel spray structures in heated and in cold environments is made by using a new laser tomographic technique and laser anemometry. The tomography technique is shown to give accurate and rapid 'point' measurements of droplet sizes and concentrations. Experimental results show acceleration of droplets to the local gas velocity, preferential vaporisation of the smallest droplets and the dispersion of droplets by the turbulence.

  1. Thermal properties measurements in biodiesel oils using photothermal techniques

    Science.gov (United States)

    Castro, M. P. P.; Andrade, A. A.; Franco, R. W. A.; Miranda, P. C. M. L.; Sthel, M.; Vargas, H.; Constantino, R.; Baesso, M. L.

    2005-08-01

    In this Letter, thermal lens and open cell photoacoustic techniques are used to measure the thermal properties of biodiesel oils. The absolute values of the thermal effusivity, thermal diffusivity, thermal conductivity and the temperature coefficient of the refractive index were determined for samples obtained from soy, castor bean, sunflower and turnip. The results suggest that the employed techniques may be useful as complementary methods for biodiesel certification.

  2. Radioactivity measurements using storage phosphor technology

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Y.T. [NeuTek, Darnestown, MD (United States); Hwang, J. [Advanced Technologies and Labs. International, Rockville, MD (United States); Hutchinson, M.R. [National Institute of Standards and Technology, Gaithersburg, MD (United States)

    1995-10-01

    We propose to apply a recently developed charged particle radiation imaging concept in bio-medical research for fast, cost-effective characterization of radionuclides in contaminated sites and environmental samples. This concept utilizes sensors with storage photostimulable phosphor (SPP) technology as radiation detectors. They exhibit high sensitivity for all types of radiation and the response is linear over a wide dynamic range (>10{sup 5}), essential for quantitative analysis. These new sensors have an Active area of up to 35 cm x 43 cm in size and a spatial resolution as fine as 50 {mu}m. They offer considerable promise as large area detectors for fast characterization of radionuclides with an added ability to locate and identify hot spots. Tests with SPP sensors have found that a single alpha particle effect can be observed and an alpha field of 100 dpm/100 cm{sup 2} or a beta activity of 0.1 dpm/mm{sup 2} or gamma radiation of few {mu}R/hr can all be measured in minutes. Radioactive isotopes can further be identified by energy discrimination which is accomplished by placing different thicknesses of filter material in front of the sensor plate. For areas with possible neutron contamination, the sensors can be coupled to a neutron to charged particle converter screen, such as dysprosium foil to detect neutrons. Our study has shown that this approach can detect a neutron flux of 1 n/cm{sup 2}s or lower, again with only minutes of exposure time. The utilization of these new sensors can significantly reduce the time and cost required for many site characterization and environmental monitoring tasks. The {open_quotes}exposure{close_quotes} time for mapping radioactivity in an environmental sample may be in terms of minutes and offer a positional resolution not obtainable with presently used counting equipment. The resultant digital image will lend itself to ready analysis.

  3. A Quantitative Approach for Measuring Technological Forecasting Capability

    OpenAIRE

    Ayhan, Mustafa Batuhan; Oztemel, Ercan

    2013-01-01

    Successful technological forecasting is important to invest scarce funds to emerging technologies. A generic model to measure the success of forecasting overall technological changes is introduced in this paper, called degree of Technological Forecasting Capability. It measures the success rate of forecasts in manufacturing processes based on four important aspects of a manufacturing system; Flow Time, Quantity/Day, Scrap Ratio, and New Investment Revenue. The proposed approach has been verif...

  4. Improving measurement technology for the design of sustainable cities

    Science.gov (United States)

    Pardyjak, Eric R.; Stoll, Rob

    2017-09-01

    This review identifies and discusses measurement technology gaps that are currently preventing major science leaps from being realized in the study of urban environmental transport processes. These scientific advances are necessary to better understand the links between atmospheric transport processes in the urban environment, human activities, and potential management strategies. We propose that with various improved and targeted measurements, it will be possible to provide technically sound guidance to policy and decision makers for the design of sustainable cities. This review focuses on full-scale in situ and remotely sensed measurements of atmospheric winds, temperature, and humidity in cities and links measurements to current modeling and simulation needs. A key conclusion of this review is that there is a need for urban-specific measurement techniques including measurements of highly-resolved three-dimensional fields at sampling frequencies high enough to capture small-scale turbulence processes yet also capable of covering spatial extents large enough to simultaneously capture key features of urban heterogeneity and boundary layer processes while also supporting the validation of current and emerging modeling capabilities.

  5. Comparison of stress-measuring techniques at the DNA-UTP site, Rodgers Hollow, Kentucky

    Energy Technology Data Exchange (ETDEWEB)

    Finley, R.E.

    1994-12-01

    The Defense Nuclear Agency (DNA) is developing explosives technology through its Underground Technology Program (UTP). Sandia National Laboratories (SNL) has supported the DNA by conducting research to characterize the in situ stress and rock mass deformability at one of the UTP underground sites at Rodgers Hollow, near Louisville, Kentucky on the Fort Knox Military Reservation. The purpose of SNL`s testing was to determine the in situ stress using three different measurement techniques and, if possible, to estimate the rock mass modulus near the underground opening. The three stress-measuring techniques are (1) borehole deformation measurements using overcoring, (2) Anelastic Strain Recovery (ASR) complemented by laboratory ultrasonic and mechanical properties testing, and (3) the in situ flatjack technique using cancellation pressure. Rock mass modulus around the underground opening was estimated using the load deformation history of the flatjack and surrounding rock. Borehole deformation measurements using the overcoring technique probably represent the most reliable method for in situ stress determination in boreholes up to 50 ft (15 m) deep in competent rock around an isolated excavation. The technique is used extensively by the tunneling and mining industries. The ASR technique is also a core-based technique and is used in the petroleum and natural gas industries for characterization of in situ stress from deep boreholes. The flatjack technique has also been used in the tunneling and mining industries, and until recently has been limited to measurement of the stress immediately around the excavation. Results from the flatjack technique must be further analyzed to calculate the in situ stress in the far field.

  6. Ultrasonic Technique for Density Measurement of Liquids in Extreme Conditions

    Directory of Open Access Journals (Sweden)

    Rymantas Kazys

    2015-08-01

    Full Text Available An ultrasonic technique, invariant to temperature changes, for a density measurement of different liquids under in situ extreme conditions is presented. The influence of geometry and material parameters of the measurement system (transducer, waveguide, matching layer on measurement accuracy and reliability is analyzed theoretically along with experimental results. The proposed method is based on measurement of the amplitude of the ultrasonic wave, reflected from the interface of the solid/liquid medium under investigation. In order to enhance sensitivity, the use of a quarter wavelength acoustic matching layer is proposed. Therefore, the sensitivity of the measurement system increases significantly. Density measurements quite often must be performed in extreme conditions at high temperature (up to 220 °C and high pressure. In this case, metal waveguides between piezoelectric transducer and the measured liquid are used in order to protect the conventional transducer from the influence of high temperature and to avoid depolarization. The presented ultrasonic density measurement technique is suitable for density measurement in different materials, including liquids and polymer melts in extreme conditions. A new calibration algorithm was proposed. The metrological evaluation of the measurement method was performed. The expanded measurement uncertainty Uρ = 7.4 × 10−3 g/cm3 (1%.

  7. [The research advance of measuring techniques on corneoscleral constitutive parameters].

    Science.gov (United States)

    Bao, Fangjun; Deng, Manli; Wang, Qinmei

    2015-11-01

    The occurrence and development of myopia and keratoconus is closely related to the changes of scleral and corneal biomechanical properties. The accurate measurement of biomechanical properties for corneoscleral tissure is very important on diagnosis of eye diseases, improvement of ocular operation, ocular biological parameter measurement and invention of ophthalmic instrument. Corneoscleral tissue, composed of bundles of compact and staggered collagen fiber and extracellular matrix, constitute the outer surface of the eyeball. The inhomogeneous distribution of the diameter, gap and amount of collagen fiber, makes its biomechanical characteristics really complex, characterized by nonlinear, viscoelastic, anisotropic, regional variation and age-related variation and etc. With the development of medical diagnostic technology, the importance of the ocular biomechanical property measurement is increasingly recognized. Nevertheless, measuring technology on ocular biomechanics properties are still not well understood by the majority of ophthalmologists. In order to facilitate the researchers to select a suitable measuring platform and method, the development of international corneoscleral biomechanical propertiy measuring technology was reviewed in this article.

  8. Reflectometry techniques for density profile measurements on fusion plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Laviron, C. [Association Euratom-CEA, Centre d`Etudes de Cadarache, 13 - Saint-Paul-lez-Durance (France). Dept. de Recherches sur la Fusion Controlee; Donne, A.J.H. [Associatie Euratom-FOM, Nieuwegein (Netherlands). FOM-Instituut voor Plasmafysica; Manso, M.E. [Instituto Superior Tecnico, Lisbon (Portugal). Lab. de Quimica Organica; Sanchez, J. [EURATOM-CIEMAT for Fusion Association, Madrid (Spain)

    1996-03-01

    Reflectometry applied to the measurement of density profiles on fusion plasmas has been subject to many recent developments. After a brief reminder of the principles of reflectometry, the theoretical accuracy of reflectometry measurements is discussed. The main difficulties limiting the performance, namely the plasma fluctuations and the quality of the transmission lines, are analysed. The different techniques used for reflectometry are then presented. The present status and achievements of actual implementations of these techniques are shown, with an analysis of their respective limitations and merits, as well as foreseen developments. (author). 70 refs.

  9. Measuring Research on County Agricultural Technological Innovation Ability Index

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    Taking the mechanism of technological construction guidance theory and mode which consists of "objective-construction-evaluation-construction-objective" as a starting point, on the basis of county agricultural technological innovation ability and its index definition, this paper researches the constructing system of county agricultural technological innovation ability. Firstly, on the basis of defining county agricultural technological innovation ability and the definition of index, according to the principle of purposefulness, scientificity, systematicness, integration of dynamic state and static state, integration of quantitativeness and qualitativeness and so on, we construct the multi-level measuring system of county agricultural technological innovation ability, including 4 first-level indices, namely technological innovation environment, technological innovation basis, technological innovation ability, and technological innovation efficiency; 15 second-level indices, such as technological policy, technological system mechanism, technological institution construction, ability of innovation subject, ability of industrial expansion, scale merit, technological contribution rate. Moreover, this system has 45 third-level indices. Then, by using unascertained mathematics method and AHM method, we establish the multi-level unascertained composite measuring model of county agricultural technological innovation ability index. Finally, by using the survey data of one county in Hebei Province, and the established county agricultural technological innovation ability index model, we get the county agricultural technological innovation ability index of 0.711 by calculation, that is, the innovation ability is at the intermediate level, namely the modern agricultural sub-stage. The empirical research proves the correctness and applicability of this model.

  10. Infrared Spectroscopy of Explosives Residues: Measurement Techniques and Spectral Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, Mark C.; Bernacki, Bruce E.

    2015-03-11

    Infrared laser spectroscopy of explosives is a promising technique for standoff and non-contact detection applications. However, the interpretation of spectra obtained in typical standoff measurement configurations presents numerous challenges. Understanding the variability in observed spectra from explosives residues and particles is crucial for design and implementation of detection algorithms with high detection confidence and low false alarm probability. We discuss a series of infrared spectroscopic techniques applied toward measuring and interpreting the reflectance spectra obtained from explosives particles and residues. These techniques utilize the high spectral radiance, broad tuning range, rapid wavelength tuning, high scan reproducibility, and low noise of an external cavity quantum cascade laser (ECQCL) system developed at Pacific Northwest National Laboratory. The ECQCL source permits measurements in configurations which would be either impractical or overly time-consuming with broadband, incoherent infrared sources, and enables a combination of rapid measurement speed and high detection sensitivity. The spectroscopic methods employed include standoff hyperspectral reflectance imaging, quantitative measurements of diffuse reflectance spectra, reflection-absorption infrared spectroscopy, microscopic imaging and spectroscopy, and nano-scale imaging and spectroscopy. Measurements of explosives particles and residues reveal important factors affecting observed reflectance spectra, including measurement geometry, substrate on which the explosives are deposited, and morphological effects such as particle shape, size, orientation, and crystal structure.

  11. Swept frequency technique for dispersion measurement of microstrip lines

    Science.gov (United States)

    Lee, Richard Q.

    1987-01-01

    Microstrip lines used in microwave integrated circuits are dispersive. Because a microstrip line is an open structure, the dispersion can not be derived with pure TEM, TE, or TM mode analysis. Dispersion analysis has commonly been done using a spectral domain approach, and dispersion measurement has been made with high Q microstrip ring resonators. Since the dispersion of a microstrip line is fully characterized by the frequency dependent phase velocity of the line, dispersion measurement of microstrip lines requires the measurement of the line wavelength as a function of frequency. In this paper, a swept frequency technique for dispersion measurement is described.

  12. Measurement of moisture in materials. Fundamentals - measuring techniques - applications - standards; Materialfeuchtemessung. Grundlagen - Messverfahren - Applikationen - Normen

    Energy Technology Data Exchange (ETDEWEB)

    Kupfer, K.; Knoechel, R.; Menke, F.; Krus, M.; Koch, W.; Brokmann, T.; Stopp, H.; Kahle, M.; Bachmann, C.; Goeller, A.; Leschnik, W.; Hauenschild, C.; Herrmann, R.; Klein, A.; Neue, J.; Haeupl, P.; Eggers, R.; Sikora, J.; Fechner, H.; Boltze, T.; Hinz, T.; Vogt, O.

    1997-12-31

    The book deals with fundamentals of moisture measurement, the physical properties of water/solids mixtures, but also reference methods such as the drying closet method, microwave drying, infrared drying, and Karl-Fischer titration. Competent experts present current methods of conductimetry, capacitive measuring techniques, microwave measuring techniques, nuclear resonance measuring techniques, nuclear radiometry techniques, infrared measuring techniques, thermal conductivity measurement techniques and hygrometric techniques. Apart from the physical bases, the authors look at factors of interference, measuring systems, as well as applications. Microwave measuring techniques offer the advantages of non-destructive measurement, independence of salt content, and density compensation. (orig./MM) 260 figs., 19 tabs., 386 refs. [Deutsch] Das Buch behandelt Grundlagen der Feuchtemessung, physikalische Eigenschaften von Wasser-Feststoff-Gemischen, aber auch Referenzverfahren, wie Trockenschrankverfahren, Mikrowellentrocknung, Infrarottrocknung und Karl-Fischer-Titration. Von kompetenten Fachleuten werden die in der Praxis ueblichen Leitfaehigkeitsmessverfahren, kapazitiven Messverfahren, Mikrowellenmessverfahren, Kernresonanzverfahren, Kernstrahlungsverfahren, Infrarot-Messverfahren, Waermeleitfaehigkeitsmessverfahren und hydrometrischen Messverfahren vorgestellt. Es werden sowohl physikalische Grundlagen, Stoergroessen, Messsysteme, aber auch Applikationen behandelt. Mikrowellenmessverfahren bieten Vorteile einer zerstoerungsfreien Messung, der Unabhaengigkeit vom Salzgehalt und Moeglichkeiten der Dichtekompensation. (orig./MM)

  13. The advance and development of damage measurement technique of rock

    Institute of Scientific and Technical Information of China (English)

    YANG Geng-she(杨更社)

    2003-01-01

    The key problem of rock damage mechanics is that determination of the variable of rock damage and the establishment of damage constitutive relation of rock, which is inevitable involved in the measurement problem of rock. In this paper, the measurement technology and method of rock damage are comprehensively narrated, analyzed and studied. On the basis of the narrating the former study, a new method (Computerized Tomography,CT for short) is introduced, which is applied to rock damage measurement. On the other hand, some newest study results and laws in the field are also introduced, which are from some scholars, the author of this paper.

  14. Updates on measurements and modeling techniques for expendable countermeasures

    Science.gov (United States)

    Gignilliat, Robert; Tepfer, Kathleen; Wilson, Rebekah F.; Taczak, Thomas M.

    2016-10-01

    The potential threat of recently-advertised anti-ship missiles has instigated research at the United States (US) Naval Research Laboratory (NRL) into the improvement of measurement techniques for visual band countermeasures. The goal of measurements is the collection of radiometric imagery for use in the building and validation of digital models of expendable countermeasures. This paper will present an overview of measurement requirements unique to the visual band and differences between visual band and infrared (IR) band measurements. A review of the metrics used to characterize signatures in the visible band will be presented and contrasted to those commonly used in IR band measurements. For example, the visual band measurements require higher fidelity characterization of the background, including improved high-transmittance measurements and better characterization of solar conditions to correlate results more closely with changes in the environment. The range of relevant engagement angles has also been expanded to include higher altitude measurements of targets and countermeasures. In addition to the discussion of measurement techniques, a top-level qualitative summary of modeling approaches will be presented. No quantitative results or data will be presented.

  15. Advanced spherical near-field antenna measurement techniques

    DEFF Research Database (Denmark)

    Nielsen, Jeppe Majlund; Pivnenko, Sergey; Breinbjerg, Olav

    2011-01-01

    The DTU-ESA facility has since the 1980es provided highly accurate antenna radiation pattern measurements and gain calibration by use of the probe corrected spherical nearfield technique, both for ESA (the European Space Agency) and other customers and continues to do so. Recent years activities ...

  16. Companding technique for high dynamic range measurements using gafchromic films

    CERN Document Server

    Heuvel, Frank Van den; Defraene, Gilles

    2011-01-01

    We propose a methodology to perform dose measurements using gafchromic films which can span several decades of dose levels. The technique is based on a rescaling approach using different films irradiated at different dose levels. This is combined with a registration protocol correcting positioning and scaling factors for each film.

  17. COMPARISON OF INTERFACIAL SURFACE TENSION AND CAPILLARITY OF MAXILLARY COMPLETE DENTURES, FABRICATED BY CONVENTIONAL CUVETTE TECHNIQUE AND INJECTION MOLDING TECHNOLOGY

    Directory of Open Access Journals (Sweden)

    Kalina Georgieva

    2016-09-01

    Full Text Available Purpose: The purpose of this in vivo study is to register the forces necessary to displace maxillary complete dentures fabricated by compression molding and injection molding techniques on one and the same patient and to compare the interfacial surface tension and capillarity which are achieved by both techniques. Material/Methods: Two maxillary complete dentures are made for each patient (total number of patients is 30 using both technologies. The magnitude of dislodging force is measured by a dynamometer. Results: Mean ± standard deviation for conventional cuvette technique is 17,53N ± 12,11N. Mean ± standard deviation for injection molding technique is 20,73N ± 13,89N. Analysis of variance (ANOVA revealed statistically significant differences in results achieved by conventional cuvette technique and injection molding technology. The results of injection technique were higher than those of compression molding technique (F=123,676, p< 0,001. Conclusions: Based on the results we suggest a standard for dislodging force of maxillary complete dentures fabricated by conventional cuvette technique- 13N, and by injection molding technology-15,5N. These values would guarantee good interfacial surface tension and capillarity. The injection molding technique was found to produce better fitting maxillary complete dentures when compared to compression molding technique. This would ensure better retention, less traumatic manifestations after insertion and higher patient’s comfort and satisfaction.

  18. Doppler lidar wind measurement with the edge technique

    Science.gov (United States)

    Korb, C. Laurence; Gentry, Bruce M.

    1992-01-01

    The edge technique is a new and powerful method for measuring small frequency shifts. Range resolved lidar measurements of winds can be made with high accuracy and high vertical resolution using the edge technique to measure the Doppler shift of an atmospheric backscattered signal from a pulsed laser. The edge technique can be used at near-infrared or visible wavelengths using well developed solid state lasers and detectors with various edge filters. In the edge technique, the laser frequency is located on the steep slope of the spectral response function of a high resolution optical filter. Due to the steep slope of the edge, very small frequency shifts cause large changes in measured signal. The frequency of the outgoing laser pulse is determined by measuring its location on the edge of the filter. This is accomplished by sending a small portion of the beam to the edge detection setup where the incoming light is split into two channels - an edge filter and an energy monitor channel. The energy monitor signal is used to normalize the edge filter signal for magnitude. The laser return backscattered from the atmosphere is collected by a telescope and directed through the edge detection setup to determine its frequency (location on the edge) in a similar manner for each range element. The Doppler shift, and thus the wind, is determined from a differential measurement of the frequency of the outgoing laser pulse and the frequency of the laser return backscattered from the atmosphere. We have conducted simulations of the performance of an edge lidar system using an injection seeded pulsed Nd:YAG laser at 1.06 microns. The central fringe of a Fabry-Perot etalon is used as a high resolution edge filter to measure the shift of the aerosol return.

  19. Accurate Fiber Length Measurement Using Time-of-Flight Technique

    Science.gov (United States)

    Terra, Osama; Hussein, Hatem

    2016-06-01

    Fiber artifacts of very well-measured length are required for the calibration of optical time domain reflectometers (OTDR). In this paper accurate length measurement of different fiber lengths using the time-of-flight technique is performed. A setup is proposed to measure accurately lengths from 1 to 40 km at 1,550 and 1,310 nm using high-speed electro-optic modulator and photodetector. This setup offers traceability to the SI unit of time, the second (and hence to meter by definition), by locking the time interval counter to the Global Positioning System (GPS)-disciplined quartz oscillator. Additionally, the length of a recirculating loop artifact is measured and compared with the measurement made for the same fiber by the National Physical Laboratory of United Kingdom (NPL). Finally, a method is proposed to relatively correct the fiber refractive index to allow accurate fiber length measurement.

  20. Electropyroelectric technique for measurement of the thermal effusivity of liquids

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, R; Moreno, I; Araujo, C [Facultad de Fisica, Universidad Autonoma de Zacatecas, Calz. Solidaridad Esquina Paseo de la Bufa s/n, C. P. 98060, Zacatecas, Zac. (Mexico); Marin, E, E-mail: emarin63@yahoo.e, E-mail: emarinm@ipn.m [Centro de Investigacion en Ciencia Aplicada y TecnologIa Avanzada, Instituto Politecnico Nacional, LegarIa 694, Colonia Irrigacion, C. P. 11500, Mexico D. F. (Mexico)

    2010-06-09

    The photopyroelectric method has been recognized as a reliable and useful tool for the measurement of the thermal properties of condensed matter samples. Usually the photothermal signal is generated using intensity modulated light beams, whose amplitudes are difficult to maintain stable. In this paper we describe a variant of this technique that uses amplitude modulated electrical current as excitation source, via Joule heating of the metal contact on one side of the pyroelectric sensor. The possibilities of this method, called by us the electropyroelectric technique, for thermal effusivity measurements of liquid samples are shown using test samples of distilled water, ethanol and glycerine. The results obtained for this parameter agree well with the values reported in the literature. Our measurement uncertainties are about 3%, a fact that opens several possible applications.

  1. Soil volumetric water content measurements using TDR technique

    Directory of Open Access Journals (Sweden)

    S. Vincenzi

    1996-06-01

    Full Text Available A physical model to measure some hydrological and thermal parameters in soils will to be set up. The vertical profiles of: volumetric water content, matric potential and temperature will be monitored in different soils. The volumetric soil water content is measured by means of the Time Domain Reflectometry (TDR technique. The result of a test to determine experimentally the reproducibility of the volumetric water content measurements is reported together with the methodology and the results of the analysis of the TDR wave forms. The analysis is based on the calculation of the travel time of the TDR signal in the wave guide embedded in the soil.

  2. Application of stereo photogrammetric techniques for measuring African Elephants

    Directory of Open Access Journals (Sweden)

    A. J Hall-Martin

    1979-01-01

    Full Text Available Measurements of shoulder height and back length of African elephants were obtained by means of stereo photogrammetric techniques. A pair of Zeiss UMK 10/1318 cameras, mounted on a steel frame on the back of a vehicle, were used to photograph the elephants in the Addo Elephant National Park, Republic of South Africa. Several modifications of normal photogrammetry procedure applicable to the field situation (eg. control points and the computation of results (eg. relative orientation are briefly mentioned. Six elephants were immobilised after being photographed and the measurements obtained from them agreed within a range of 1 cm-10 cm with the photogrammetric measurements.

  3. High resolution resonant recombination measurements using evaporative cooling technique

    Energy Technology Data Exchange (ETDEWEB)

    Beilmann, C; Lopez-Urrutia, J R Crespo; Mokler, P H; Ullrich, J, E-mail: christian.beilmann@mpi-hd.mpg.d [Max-Planck-Institut fuer Kernphysik, Saupfercheckweg 1, 69117 Heidelberg (Germany)

    2010-09-15

    We report on a method significantly improving the energy resolution of dielectronic recombination (DR) measurements in electron beam ion traps (EBITs). The line width of DR resonances can be reduced to values distinctly smaller than the corresponding space charge width of the uncompensated electron beam. The experimental technique based on forced evaporative cooling is presented together with test measurements demonstrating its high efficiency. The principle for resolution improvement is elucidated and the limiting factors are discussed. This method opens access to high resolution DR measurements at high ion-electron collision energies required for innermost shell DR in highly charged ions (HCI).

  4. Sound Power Estimation by Laser Doppler Vibration Measurement Techniques

    Directory of Open Access Journals (Sweden)

    G.M. Revel

    1998-01-01

    Full Text Available The aim of this paper is to propose simple and quick methods for the determination of the sound power emitted by a vibrating surface, by using non-contact vibration measurement techniques. In order to calculate the acoustic power by vibration data processing, two different approaches are presented. The first is based on the method proposed in the Standard ISO/TR 7849, while the second is based on the superposition theorem. A laser-Doppler scanning vibrometer has been employed for vibration measurements. Laser techniques open up new possibilities in this field because of their high spatial resolution and their non-intrusivity. The technique has been applied here to estimate the acoustic power emitted by a loudspeaker diaphragm. Results have been compared with those from a commercial Boundary Element Method (BEM software and experimentally validated by acoustic intensity measurements. Predicted and experimental results seem to be in agreement (differences lower than 1 dB thus showing that the proposed techniques can be employed as rapid solutions for many practical and industrial applications. Uncertainty sources are addressed and their effect is discussed.

  5. Plasma scattering of electromagnetic radiation theory and measurement techniques

    CERN Document Server

    Froula, Dustin H; Luhmann, Neville C Jr; Sheffield, John

    2011-01-01

    This work presents one of the most powerful methods of plasma diagnosis in exquisite detail to guide researchers in the theory and measurement techniques of light scattering in plasmas. Light scattering in plasmas is essential in the research and development of fusion energy, environmental solutions, and electronics.Referred to as the "Bible" by researchers the work encompasses fusion and industrial applications essential in plasma research. It is the only comprehensive resource specific to the plasma scattering technique. It provides a wide-range of experimental examples and discussion of the

  6. Technology Assessment of Dust Suppression Techniques Applied During Structural Demolition

    Energy Technology Data Exchange (ETDEWEB)

    Boudreaux, J.F.; Ebadian, M.A.; Williams, P.T.; Dua, S.K.

    1998-10-20

    Hanford, Fernald, Savannah River, and other sites are currently reviewing technologies that can be implemented to demolish buildings in a cost-effective manner. In order to demolish a structure properly and, at the same time, minimize the amount of dust generated from a given technology, an evaluation must be conducted to choose the most appropriate dust suppression technology given site-specific conditions. Thus, the purpose of this research, which was carried out at the Hemispheric Center for Environmental Technology (HCET) at Florida International University, was to conduct an experimental study of dust aerosol abatement (dust suppression) methods as applied to nuclear D and D. This experimental study targeted the problem of dust suppression during the demolition of nuclear facilities. The resulting data were employed to assist in the development of mathematical correlations that can be applied to predict dust generation during structural demolition.

  7. Human monitoring, smart health and assisted living techniques and technologies

    CERN Document Server

    Longhi, Sauro; Freddi, Alessandro

    2017-01-01

    This book covers the three main scientific and technological areas critical for improving people's quality of life - namely human monitoring, smart health and assisted living - from both the research and development points of view.

  8. High-sensitive Optical Pulse-Shape Characterization using a Beating-Contrast-Measurement Technique

    CERN Document Server

    Roncin, Vincent; Millaud, Audrey; Cramer, Romain; Jaouën, Yves; Simon, Jean-Claude

    2014-01-01

    Ultrahigh-speed optical transmission technology, such as optical time domain multiplexing or optical signal processing is a key point for increasing the communication capacity. The system performances are strongly related to pulse properties. We present an original method dedicated to short pulse-shape characterization with high repetition rate using standard optical telecommunications equipments. Its principle is based on temporal measurement of the contrast produced by the beating of two delayed optical pulses in a high bandwidth photo detector. This technique returns firstly reliable information on the pulse-shape, such as pulse width, shape and pedestal. Simulation and experimental results evaluate the high-sensitivity and the high-resolution of the technique allowing the measurement of pulse extinction ratio up to 20 dB with typical timing resolution of about 100 fs. The compatibility of the technique with high repetition rate pulse measurement offers an efficient tool for short pulse analysis.

  9. Lower cost air measurement technology – what is on the ...

    Science.gov (United States)

    This presentation is to the MARAMA 2014 annual monitoring meeting and is an invited talk to provide an overview on lower cost air measurement technology. This presentation is to the MARAMA 2014 annual monitoring meeting and is an invited talk to provide an overview on lower cost air measurement technology.

  10. Unit vent airflow measurements using a tracer gas technique

    Energy Technology Data Exchange (ETDEWEB)

    Adams, D.G. [Union Electric Company, Fulton, MO (United States); Lagus, P.L. [Lagus Applied Technology, Inc., San Diego, CA (United States); Fleming, K.M. [NCS Corp., Columbus, OH (United States)

    1997-08-01

    An alternative method for assessing flowrates that does not depend on point measurements of air flow velocity is the constant tracer injection technique. In this method one injects a tracer gas at a constant rate into a duct and measures the resulting concentration downstream of the injection point. A simple equation derived from the conservation of mass allows calculation of the flowrate at the point of injection. Flowrate data obtained using both a pitot tube and a flow measuring station were compared with tracer gas flowrate measurements in the unit vent duct at the Callaway Nuclear Station during late 1995 and early 1996. These data are presented and discussed with an eye toward obtaining precise flowrate data for release rate calculations. The advantages and disadvantages of the technique are also described. In those test situations for which many flowrate combinations are required, or in large area ducts, a tracer flowrate determination requires fewer man-hours than does a conventional traverse-based technique and does not require knowledge of the duct area. 6 refs., 10 figs., 6 tabs.

  11. Measurement of epithermal neutrons by a coherent demodulation technique

    CERN Document Server

    Horiuchi, N; Takahashi, H; Kobayashi, H; Harasawa, S

    2000-01-01

    Epithermal neutrons have been measured using a neutron dosimeter via a coherent demodulation technique. This dosimeter consists of CsI(Tl)-photodiode scintillation detectors, four of which are coupled to neutron-gamma converting foils of various sizes. Neutron-gamma converting foils of In, Au and Co materials were used, each of which has a large capture cross section which peaks in the epithermal neutron energy region. The type of foil was selected according to the material properties that best correspond to the energy of the epithermal neutrons to be measured. In addition, the proposed technique was applied using Au-foils in order to measure the Cd ratio. The validity of the proposed technique was examined using an sup 2 sup 4 sup 1 Am-Be source placed in a testing stack of polyethylene blocks, and the results were compared with the theoretical values calculated by the Monte Carlo calculation. Finally, the dosimeter was applied for measuring epithermal neutrons and the Cd ratio in an experimental beam-tube o...

  12. Minimizing errors in phase change correction measurements for gauge blocks using a spherical contact technique

    Science.gov (United States)

    Stoup, John R.; Faust, Bryon S.; Doiron, Theodore D.

    1998-09-01

    One of the most elusive measurement elements in gage block interferometry is the correction for the phase change on reflection. Techniques used to quantify this correction have improved over the year, but the measurement uncertainty has remained relatively constant because some error sources have proven historically difficult to reduce. The precision engineering division at the National Institute of Standards and Technology has recently developed a measurement technique that can quantify the phase change on reflection correction directly for individual gage blocks and eliminates some of the fundamental problems with historical measurement methods. Since only the top surface of the gage block is used in the measurement, wringing film inconsistencies are eliminated with this technique thereby drastically reducing the measurement uncertainty for the correction. However, block geometry and thermal issues still exist. This paper will describe the methods used to minimize the measurement uncertainty of the phase change on reflection evaluation using a spherical contact technique. The work focuses on gage block surface topography and drift eliminating algorithms for the data collection. The extrapolation of the data to an undeformed condition and the failure of these curves to follow theoretical estimates are also discussed. The wavelength dependence of the correction was directly measured for different gage block materials and manufacturers and the data will be presented.

  13. Objective techniques for psychological assessment, phase 2. [techniques for measuring human performance during space flight stress

    Science.gov (United States)

    Wortz, E. C.; Saur, A. J.; Nowlis, D. P.; Kendall, M. P.

    1974-01-01

    Results are presented of an initial experiment in a research program designed to develop objective techniques for psychological assessment of individuals and groups participating in long-duration space flights. Specifically examined is the rationale for utilizing measures of attention as an objective assessment technique. Subjects participating in the experiment performed various tasks (eg, playing matrix games which appeared on a display screen along with auditory stimuli). The psychophysiological reactions of the subjects were measured and are given. Previous research of various performance and psychophysiological methods of measuring attention is also discussed. The experiment design (independent and dependent variables) and apparatus (computers and display devices) are described and shown. Conclusions and recommendations are presented.

  14. Gamma ray densitometry techniques for measuring of volume fractions

    Energy Technology Data Exchange (ETDEWEB)

    Affonso, Renato Raoni Werneck; Silva, Ademir Xavier da; Salgado, Cesar Marques, E-mail: raoniwa@yahoo.com.br, E-mail: ademir@nuclear.ufrj.br, E-mail: otero@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    Knowledge of the volume fraction in a multiphase flow is of key importance in predicting the performance of many systems and processes. It is therefore an important parameter to characterize such flows. In the context of nuclear techniques, the gamma ray densitometry is promising and this is due to its non-invasive characteristics and very reliable results. It is used in several applications for multiphase flows (water-oil-air), which are employed tools such as: computational fluid dynamics, artificial neural networks and statistical methods of radiation transport, such as the Monte Carlo method. Based on the gamma radiation techniques for measurements of volume fractions, the aim of this paper is to present several techniques developed for this purpose. (author)

  15. A new technique to measure the differential XAFS spectrum

    Science.gov (United States)

    Wu, Min; Zheng, Li-Rong; Chu, Sheng-Qi; Zhou, Ai-Yu; Zhang, Jing; Hu, Tian-Dou

    2016-04-01

    A new technique has been developed for direct measurement of the differential X-ray absorption fine structure (XAFS) spectrum by the energy-modulation method. To acquire the energy-oscillating incident X-ray beam, a piezoelectric actuator is used to control the double-crystal monochromator. A logarithmic converter circuit and a lock-in amplifier are used to extract the modulated signals. The normal and differential XAFS spectra of the Mn K-edge of Li2MnO3 have been collected. The X-ray-absorption near-edge-structure (XANES) spectra verify that the signal-to-noise ratio has been greatly improved by the new technique, and the extended X-ray absorption fine structure (EXAFS) spectra demonstrate that this new technique can efficiently enhance the signals of the backscattering atoms. Supported by NSFC (11175202)

  16. Passive RF component technology materials, techniques, and applications

    CERN Document Server

    Wang, Guoan

    2012-01-01

    Focusing on novel materials and techniques, this pioneering volume provides you with a solid understanding of the design and fabrication of smart RF passive components. You find comprehensive details on LCP, metal materials, ferrite materials, nano materials, high aspect ratio enabled materials, green materials for RFID, and silicon micromachining techniques. Moreover, this practical book offers expert guidance on how to apply these materials and techniques to design a wide range of cutting-edge RF passive components, from MEMS switch based tunable passives and 3D passives, to metamaterial-bas

  17. New developments in the laser-2-focus technique for non-intrusive velocity measurements in gasturbine components

    Science.gov (United States)

    Schodl, Richard; Förster, Wolfgang

    1992-04-01

    Further improvement of aircraft engines with respect to fuel consumption and emission reduction requires costly and difficult investigations which are impossible without modern measuring techniques. The Institute of Propulsion Technology is primarily concerned with investigations on turbomachinery components (e.g. compressors, combustors, turbines), where very often extremely difficult conditions prevail (high flow velocities, complex geometries, rotating flow channels). For this reason non-intrusive measuring techniques play an important role. The Laser-2-Focus technique for non-intrusive velocity measurements developed in the institute has won high regard worldwide. Developments in optics and electronics have resulted in this technique having a considerably greater area of application.

  18. Fourier transform approach in modulation technique of experimental measurements.

    Science.gov (United States)

    Khazimullin, M V; Lebedev, Yu A

    2010-04-01

    An application of Fourier transform approach in modulation technique of experimental studies is considered. This method has obvious advantages compared with traditional lock-in amplifiers technique--simple experimental setup, a quickly available information on all the required harmonics, high speed of data processing using fast Fourier transform algorithm. A computationally simple, fast and accurate Fourier coefficients interpolation (FCI) method has been implemented to obtain a useful information from harmonics of a multimode signal. Our analysis shows that in this case FCI method has a systematical error (bias) of a signal parameters estimation, which became essential for the short data sets. Hence, a new differential Fourier coefficients interpolation (DFCI) method has been suggested, which is less sensitive to a presence of several modes in a signal. The analysis has been confirmed by simulations and measurements of a quartz wedge birefringence by means of the photoelastic modulator. The obtained bias, noise level, and measuring speed are comparable and even better than in lock-in amplifier technique. Moreover, presented DFCI method is expected to be promised candidate for using in actively developing imaging systems based on the modulation technique requiring fast digital signal processing of large data sets.

  19. Immersed in media telepresence theory, measurement & technology

    CERN Document Server

    Lombard, Matthew; Freeman, Jonathan; IJsselsteijn, Wijnand; Schaevitz, Rachel J

    2015-01-01

    Highlights key research currently being undertaken within the field of telepresence, providing the most detailed account of the field to date, advancing our understanding of a fundamental property of all media - the illusion of presence; the sense of "being there" inside a virtual environment, with actual or virtual others. This collection has been put together by leading international scholars from America, Europe, and Asia. Together, they describe the state-of-the-art in presence theory, research and technology design for an advanced academic audience. Immersed in Media provides research t

  20. A new measuring technique of soil thermal inertia

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    Thermal inertia is the function of substance density,heat capacity and heat diffusivity,and is an important parameter for researching the process of surface heat balance using remote sensing technique.In this paper,using soil heat plates,infrared thermometer,data logger and other instruments,by man-controlled changing the solar radiation status on the soil samples,the authors gave a new method to measure soil thermal inertia.Using the continuously surveying data of soil heat flux and infrared radiation temperature,thermal inertia can be calculated easily.Based on the thermal inertia calculation of three soil samples with different water content,good results were abtained by the authors,so this method is feasible.Meanwhile,this measuring technique is also a new attempt.

  1. A new measuring technique of soil thermal inertia

    Institute of Scientific and Technical Information of China (English)

    孙晓敏; 朱治林; 唐新斋; 苏红波; 张仁华

    2000-01-01

    Thermal inertia is the function of substance density, heat capacity and heat diffusivity, and is an important parameter for researching the process of surface heat balance using remote sensing technique. In this paper, using soil heat plates, infrared thermometer, data logger and other instruments, by man-controlled changing the solar radiation status on the soil samples, the authors gave a new method to measure soil thermal inertia. Using the continuously surveying data of soil heat flux and infrared radiation temperature, thermal inertia can be calculated easily. Based on the thermal inertia calculation of three soil samples with different water content, good results were abtained by the authors, so this method is feasible. Meanwhile, this measuring technique is also a new attempt.

  2. Verification of long-term load measurement technique

    DEFF Research Database (Denmark)

    Schmidt Paulsen, Uwe

    The present report is the final effort of tasks carried out under UPWIND WP1B2 transmission and conversion, which describes: 1) results and recommendations developed in the course of developing the long-term load measurement technique 2) the hardware details, type of sensors and location, data...... storage and 3) data analysis technique to verify design load assumptions. The work is carried out under Contract no 019945 (SES6) "UPWIND" within the European Commission The interaction between the mechanical and electrical generator subsystems is described rudimentarily, based primarily on HAWC2...... simulations below stall of the mechanical system with simple generator and gearbox systems. The electrical system simulations were not carried out as intended in DOW[2], but indications of the conditions for establishing the interaction have been described by measurements and by argument, that this might have...

  3. APPLICATION OF NOVEL NEUTRON CORRELATION TECHNIQUES TO NUCLEAR MATERIAL MEASUREMENTS

    Energy Technology Data Exchange (ETDEWEB)

    Sale, K

    2006-06-09

    Confirmation of the fissile mass of a system containing plutonium can be done using neutron multiplicity techniques. This can be accomplished with a detector system that is smaller and less costly than a standard neutron multiplicity counter (NMC). Also the fissile mass of a uranium containing system can be confirmed by passive means. Recent work at Lawrence Livermore National Laboratory has demonstrated that simple slab neutron detectors and a novel approach to data acquisition and analysis can be used to make an accurate measurement of the mass of fissile materials. Purely passive measurement of kilogram quantities of highly enriched uranium (HEU) have also been shown to be feasible. In this paper we discuss calculational tools for assessing the application of these techniques to fissile material transparency regimes. The tools required to adequately model the correlations and their application will be discussed.

  4. 3D interferometric shape measurement technique using coherent fiber bundles

    Science.gov (United States)

    Zhang, Hao; Kuschmierz, Robert; Czarske, Jürgen

    2017-06-01

    In-situ 3-D shape measurements with submicron shape uncertainty of fast rotating objects in a cutting lathe are expected, which can be achieved by simultaneous distance and velocity measurements. Conventional tactile methods, coordinate measurement machines, only support ex-situ measurements. Optical measurement techniques such as triangulation and conoscopic holography offer only the distance, so that the absolute diameter cannot be retrieved directly. In comparison, laser Doppler distance sensors (P-LDD sensor) enable simultaneous and in-situ distance and velocity measurements for monitoring the cutting process in a lathe. In order to achieve shape measurement uncertainties below 1 μm, a P-LDD sensor with a dual camera based scattered light detection has been investigated. Coherent fiber bundles (CFB) are employed to forward the scattered light towards cameras. This enables a compact and passive sensor head in the future. Compared with a photo detector based sensor, the dual camera based sensor allows to decrease the measurement uncertainty by the order of one magnitude. As a result, the total shape uncertainty of absolute 3-D shape measurements can be reduced to about 100 nm.

  5. Selective Chemical-Lithographic Reaction Techniques Using Radiation Technology for Biological Application

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Kwan Woo; Kim, Keo Su; Kim, Hyun Jung; Kim, Hee Suk; Lee, Mi Jin [Sogang University, Seoul (Korea, Republic of)

    2010-05-15

    This report, titled 'selective Chemical-Lithographic Reaction Techniques Using Radiation Technology for Biological Application' contains a research summary, 1) development of selective reaction technology using irradiation of electron beams, 2) preparation of functional surfaces using selective radiation technology on carbon-based nanomaterials, and 3) development of bio-applicable biochips using combinatorial surface modification

  6. Supervision over technological and measurement processes

    Directory of Open Access Journals (Sweden)

    T. Karkoszka

    2011-01-01

    Full Text Available Purpose: of the paper has been an attainment of the thesis: “If there is something we can define, we can measure it. If there is something we can measure, we can analyse that. If there is something we can analyse, we can supervise that. If there is something we can supervise, we can improve that [1]”.Design/methodology/approach: used for the analysis has covered proposition of the supervision over measurement processes system that can be applied in quality assurance.Findings: of analysis are as follows: system of supervision over measurement processes performed (in compliance with real, realised in an organisation processes, can assure the achievement of the accurate and reliable results that, being the base of any feedback in any process, have fundamental meaning in making appropriate decisions.Practical implications: can be applied in case of any organisation, wanting to demonstrate the conformity of processes in the range of requirements that apply to: products, workers, natural environment and others by supervision over measurement equipment.Originality/value: of the presented paper has been obtained by working out the design of supervision over measurement system, also measurement system capability, which should be supplement for supervision over processes system in the assurance of processes and products quality.

  7. Measurement Techniques for Electrothermal-Chemical Gun Diagnostics

    Science.gov (United States)

    1993-12-01

    conductors of a circuit ( Askeland 1985). This technique has been successfully applied to other experimental work including the pressure measurements made in...Fe2O4 ( Askeland 1985). Ferrites are implemented by wrapping the power cords and coaxial data lines of all electronics equipment tightly for several... Askeland , D. R. The Sciece and Engineering of Materials. Prindle, Weber, and Schmidt, 1985. Burden. H. S., and D. D. Shear. "Transient Noise in Electronic

  8. Experimental Methods Using Photogrammetric Techniques for Parachute Canopy Shape Measurements

    Science.gov (United States)

    Jones, Thomas W.; Downey, James M.; Lunsford, Charles B.; Desabrais, Kenneth J.; Noetscher, Gregory

    2007-01-01

    NASA Langley Research Center in partnership with the U.S. Army Natick Soldier Center has collaborated on the development of a payload instrumentation package to record the physical parameters observed during parachute air drop tests. The instrumentation package records a variety of parameters including canopy shape, suspension line loads, payload 3-axis acceleration, and payload velocity. This report discusses the instrumentation design and development process, as well as the photogrammetric measurement technique used to provide shape measurements. The scaled model tests were conducted in the NASA Glenn Plum Brook Space Propulsion Facility, OH.

  9. Measurements of diversity gain and radiation efficiency of the eleven antenna by using different measurement techniques

    DEFF Research Database (Denmark)

    Yang, Jian; Pivnenko, Sergey; Laitinen, Tommi

    2010-01-01

    This paper presents measurement results of diversity gain and radiation efficiency by using three different measurement techniques: reverberation chamber, spherical near-field anechoic chamber, and multi-probe anechoic chamber. The results are measured over a large 2–8 GHz bandwidth which...

  10. Vibration frequency measurement using a local multithreshold technique.

    Science.gov (United States)

    Ferrer, Belen; Espinosa, Julian; Roig, Ana B; Perez, J; Mas, D

    2013-11-01

    In this paper, we demonstrate the use of a video camera for measuring the frequency of small-amplitude vibration movements. The method is based on image acquisition and multilevel thresholding and it only requires a video camera with high enough acquisition rate, not being necessary the use of targets or auxiliary laser beams. Our proposal is accurate and robust. We demonstrate the technique with a pocket camera recording low-resolution videos with AVI-JPEG compression and measuring different objects that vibrate in parallel or perpendicular direction to the optical sensor. Despite the low resolution and the noise, we are able to measure the main vibration modes of a tuning fork, a loudspeaker and a bridge. Results are successfully compared with design parameters and measurements with alternative devices.

  11. Data fusion techniques for incomplete measurement of trajectory

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    This paper focuses on data processing for incomplete measurementof trajectory (IMT) in aerospace mea- surement and control. The IMT means that the principal equipment loses the measured data during some intervals so that trajectory parameters (position, velocity, etc.) cannot be determined independently. Based on a joint model for trajectory estimation with reduced parameter, a fusion way is put forth by making full use of measured data from auxiliary equipment with lower precision. In the superposition intervals of measurement between principal and auxiliary equipment, the technique of diagnosing and estimating system errors is applied to improving the estimate precision of trajectory parameters (TP) and determining the precision after data fusion. In practical test, this method operates so successfully that it can not only provide complete TP but improve their precision remarkably. Meanwhile, this way is also applicable to other problems of incomplete measurement.

  12. A new distensibility technique to measure sphincter of Oddi function

    DEFF Research Database (Denmark)

    Kunwald, Peter; Drewes, Asbjørn Mohr; Kjær, D.;

    2010-01-01

    . Methods The SO probe was constructed to measure eight cross-sectional areas (CSA) along a length of 25 mm inside a saline-filled bag. To validate the technique for profiling the SO, six perspex cylinders with different CSAs were measured nine times to assess reproducibility and accuracy. Key Results...... probe and validating it for measurements in the SO. In order to get a better physiological understanding of the SO the aims were to show the sphincter profile in vivo and motility patterns of SO in pilot studies using volunteers that were experiencing biliary type pain but had normal SO manometry...... Reproducibility and accuracy for these measurements were good. The probe performed well in bench tests and was therefore tested in four humans. The data indicated that it was possible to make distensions in the human SO and that a geometric sphincter profile could be obtained. Conclusions & Inferences The probe...

  13. A study of the river velocity measurement techniques and analysis methods

    Science.gov (United States)

    Chung Yang, Han; Lun Chiang, Jie

    2013-04-01

    Velocity measurement technology can be traced back to the pitot tube velocity measurement method in the 18th century and today's velocity measurement technology use the acoustic and radar technology, with the Doppler principle developed technology advances, in order to develop the measurement method is more suitable for the measurement of velocity, the purpose is to get a more accurate measurement data and with the surface velocity theory, the maximum velocity theory and the indicator theory to obtain the mean velocity. As the main research direction of this article is to review the literature of the velocity measurement techniques and analysis methods, and to explore the applicability of the measurement method of the velocity measurement instruments, and then to describe the advantages and disadvantages of the different mean velocity profiles analysis method. Adequate review of the references of this study will be able to provide a reference for follow-up study of the velocity measurement. Review velocity measurement literature that different velocity measurement is required to follow the different flow conditions measured be upgraded its accuracy, because each flow rate measurement method has its advantages and disadvantages. Traditional velocity instrument can be used at low flow and RiverRAD microwave radar or imaging technology measurement method may be applied in high flow. In the tidal river can use the ADCP to quickly measure river vertical velocity distribution. In addition, urban rivers may be used the CW radar to set up on the bridge, and wide rivers can be used RiverRAD microwave radar to measure the velocities. Review the relevant literature also found that using Ultrasonic Doppler Current Profiler with the Chiu's theory to the velocity of observing automation work can save manpower and resources to improve measurement accuracy, reduce the risk of measurement, but the great variability of river characteristics in Taiwan and a lot of drifting floating

  14. Thermal Warpage Measurement of Electronic Packages by Shadow Moiré with Phase Stepping Technique

    Institute of Scientific and Technical Information of China (English)

    Yinyan Wang

    2011-01-01

    Phase-stepping technique is applied to the analysis of fringe patterns of shadow moiré of electronic packages.Sensitivity of the fringe pattern analysis is demonstrated to be significantly increased. Thermally induced warpage of electronic packages is successfully measured in real-time as the sample is driven through a simulated reflow process.The paper discusses the technique of phase stepping,noise filtering and its application to the shadow moiré method.Applications of the technology are presented.

  15. Malmquist Index, an Alternative Technique for Measuring Credit Institutions Productivity

    Directory of Open Access Journals (Sweden)

    Nicolae Dardac

    2008-03-01

    Full Text Available The present study tackles the banking system’s productivity in a more complex manner, that integrates multiple input, multiple output variables, abdicating from the reductionist perspective of clasical methods, which imposed limits in the number of variables, in the process of productivity measurement and interpretation. The advantage of Malmquist productivity indexes consists both in a quantitative evaluation of the global productivity of a credit institution over a specified period of time, and in the decomposition of productivity, in order to underline how much of its change is due to the catch-up effect, and, respectively, to the implementation of new technologies. The results obtained revealed that credit institutions placed on the first three places in the banking system, according to assets value, maintained constant their productivity level during the analysed period, meanwhile the other institutions in our sample registered a slowly improvement in productivity, determined, mainly, by technological changes.

  16. Training Manual on Food Irradiation Technology and Techniques.

    Science.gov (United States)

    United Nations Food and Agriculture Organization, Rome (Italy).

    This training manual consists of two parts. The first covers general information and outlines various applications of food irradiation technology. The second section details laboratory exercises used to demonstrate the principles of radiation processing and the effects of radiation treatment on certain types of food. The chapters outline…

  17. Novel microstructures and technologies applied in chemical analysis techniques

    NARCIS (Netherlands)

    Spiering, Vincent L.; Spiering, V.L.; van der Moolen, Johannes N.; Burger, Gert-Jan; Burger, G.J.; van den Berg, Albert

    1997-01-01

    Novel glass and silicon microstructures and their application in chemical analysis are presented. The micro technologies comprise (deep) dry etching, thin layer growth and anodic bonding. With this combination it is possible to create high resolution electrically isolating silicon dioxide structures

  18. Development of Technology Readiness Level (TRL) Metrics and Risk Measures

    Energy Technology Data Exchange (ETDEWEB)

    Engel, David W.; Dalton, Angela C.; Anderson, K. K.; Sivaramakrishnan, Chandrika; Lansing, Carina

    2012-10-01

    This is an internal project milestone report to document the CCSI Element 7 team's progress on developing Technology Readiness Level (TRL) metrics and risk measures. In this report, we provide a brief overview of the current technology readiness assessment research, document the development of technology readiness levels (TRLs) specific to carbon capture technologies, describe the risk measures and uncertainty quantification approaches used in our research, and conclude by discussing the next steps that the CCSI Task 7 team aims to accomplish.

  19. Improved Tandem Measurement Techniques for Aerosol Particle Analysis

    Science.gov (United States)

    Rawat, Vivek Kumar

    Non-spherical, chemically inhomogeneous (complex) nanoparticles are encountered in a number of natural and engineered environments, including combustion systems (which produces highly non-spherical aggregates), reactors used in gas-phase materials synthesis of doped or multicomponent materials, and in ambient air. These nanoparticles are often highly diverse in size, composition and shape, and hence require determination of property distribution functions for accurate characterization. This thesis focuses on development of tandem mobility-mass measurement techniques coupled with appropriate data inversion routines to facilitate measurement of two dimensional size-mass distribution functions while correcting for the non-idealities of the instruments. Chapter 1 provides the detailed background and motivation for the studies performed in this thesis. In chapter 2, the development of an inversion routine is described which is employed to determine two dimensional size-mass distribution functions from Differential Mobility Analyzer-Aerosol Particle Mass analyzer tandem measurements. Chapter 3 demonstrates the application of the two dimensional distribution function to compute cumulative mass distribution function and also evaluates the validity of this technique by comparing the calculated total mass concentrations to measured values for a variety of aerosols. In Chapter 4, this tandem measurement technique with the inversion routine is employed to analyze colloidal suspensions. Chapter 5 focuses on application of a transverse modulation ion mobility spectrometer coupled with a mass spectrometer to study the effect of vapor dopants on the mobility shifts of sub 2 nm peptide ion clusters. These mobility shifts are then compared to models based on vapor uptake theories. Finally, in Chapter 6, a conclusion of all the studies performed in this thesis is provided and future avenues of research are discussed.

  20. Technique and experiment of active direct gas pressure measurement in coal roadway

    Energy Technology Data Exchange (ETDEWEB)

    Xue-xi Chen; Shang-quan Ma; Li-ming Qi [North China Institute of Science and Technology, Beijing (China). School of Safety Engineering

    2009-06-15

    An active measurement method and its principle was introduced considering the low success rate, special difficulty, and long measurement time of the direct gas pressure measurement currently used in coal roadways. The technology of drilling, borehole sealing depth, borehole sealing length, sealing control of the measuring process, compensatory computation of gas loss quantity and other key techniques were discussed. Finally, based on the latest instrument the authors developed, a series of experiments of direct gas pressure measurement in the coal roadways of the Jincheng and Tongchuan mine district, were carried out. The experimental results show that active gas pressure measurement technique has advantages as follows: (1) the application scope of direct gas pressure measurement technique is wide and it does not have the restriction of coal hardness, coal seam fissure and other conditions; (2) the measured results are credible, which can be tested by the same gas pressure value acquired from a different borehole in the same place; (3) the measurement process is convenient and quick, it takes about 2 to 3 days to acquire the gas pressure value in a coal seam. 8 refs., 1 fig., 2 tabs.

  1. Technique and experiment of active direct gas pressure measurement in coal roadway

    Institute of Scientific and Technical Information of China (English)

    CHEN Xue-xi; MA Shang-quan; QI Li-ming

    2009-01-01

    An active measurement method and its principle was introduced considering the low success rate, special difficulty, and long measurement time of the direct gas pres-sure measurement currently used in coal roadways. The technology of drilling, borehole sealing depth, borehole sealing length, sealing control of the measuring process, com-pensatory computation of gas loss quantity and other key techniques were discussed. Fi-nally, based on the latest instrument the authors developed, a series of experiments of di-rect gas pressure measurement in the coal roadways of the Jincheng and Tongchuan mine district, were carried out. The experimental results show that active gas pressure measurement technique has advantages as follows: (1) the application scope of direct gas pressure measurement technique is wide and it does not have the restriction of coal hardness, coal seam fissure and other conditions; (2) the measured results are credible, which can be tested by the same gas pressure value acquired from a different borehole in the same place; (3) the measurement process is convenient and quick, it takes about 2 to 3 days to acquire the gas pressure value in a coal seam.

  2. Measuring glioma volumes: A comparison of linear measurement based formulae with the manual image segmentation technique

    Directory of Open Access Journals (Sweden)

    Sanjeev A Sreenivasan

    2016-01-01

    Conclusions: Manual region of interest-based image segmentation is the standard technique for measuring glioma volumes. For routine clinical use, the simple formula v = abc/2 (or the formula for volume of an ellipsoid could be used as alternatives.

  3. Monitoring fugitive methane and natural gas emissions, validation of measurement techniques.

    Science.gov (United States)

    Robinson, Rod; Innocenti, Fabrizio; Gardiner, Tom; Helmore, Jon; Finlayson, Andrew; Connor, Andy

    2017-04-01

    The detection and quantification of fugitive and diffuse methane emissions has become an increasing priority in recent years. As the requirements for routine measurement to support industry initiatives increase there is a growing requirement to assess and validate the performance of fugitive emission measurement technologies. For reported emissions traceability and comparability of measurements is important. This talk will present recent work addressing these needs. Differential Absorption Lidar (DIAL) is a laser based remote sensing technology, able to map the concentration of gases in the atmosphere and determine emission fluxes for fugitive emissions. A description of the technique and its application for determining fugitive emissions of methane from oil and gas operations and waste management sites will be given. As DIAL has gained acceptance as a powerful tool for the measurement and quantification of fugitive emissions, and given the rich data it produces, it is being increasingly used to assess and validate other measurement approaches. In addition, to support the validation of technologies, we have developed a portable controlled release facility able to simulate the emissions from area sources. This has been used to assess and validate techniques which are used to monitor emissions. The development and capabilities of the controlled release facility will be described. This talk will report on recent studies using DIAL and the controlled release facility to validate fugitive emission measurement techniques. This includes side by side comparisons of two DIAL systems, the application of both the DIAL technique and the controlled release facility in a major study carried out in 2015 by South Coast Air Quality Management District (SCAQMD) in which a number of optical techniques were assessed and the development of a prototype method validation approach for techniques used to measure methane emissions from shale gas sites. In conclusion the talk will provide an

  4. Spherical near-field antenna measurements — The most accurate antenna measurement technique

    DEFF Research Database (Denmark)

    Breinbjerg, Olav

    2016-01-01

    The spherical near-field antenna measurement technique combines several advantages and generally constitutes the most accurate technique for experimental characterization of radiation from antennas. This paper/presentation discusses these advantages, briefly reviews the early history and present...... status, and addresses future challenges for spherical near-field antenna measurements; in particular, from the viewpoint of the DTU-ESA Spherical Near-Field Antenna Test Facility....

  5. High-speed railway bridge dynamic measurement based on GB-InSAR technology

    Science.gov (United States)

    Liu, Miao; Ding, Ke-liang; Liu, Xianglei; Song, Zichao

    2015-12-01

    It is an important task to evaluate the safety during the life of bridges using the corresponding vibration parameters. With the advantages of non-contact and high accuracy, the new remote measurement technology of GB-InSAR is suitable to make dynamic measurement for bridges to acquire the vibration parameters. Three key technologies, including stepped frequency-continuous wave technique, synthetic aperture radar and interferometric measurement technique, are introduced in this paper. The GB-InSAR is applied for a high-speed railway bridge to measure of dynamic characteristics with the train passing which can be used to analyze the safety of the monitored bridge. The test results shown that it is an reliable non-contact technique for GB-InSAR to acquire the dynamic vibration parameter for the high-speed railway bridges.

  6. Radiographic measurements of hallux angles: a review of current techniques.

    Science.gov (United States)

    Srivastava, Subodh; Chockalingam, N; El Fakhri, Tarek

    2010-03-01

    Radiographic angles are commonly used in patients with hallux valgus deformity to assess the severity, plan surgery, assess outcome and compare results. Many different manual methods have been used, but are prone to error. More recently computer-assisted methods using software have become available. To review the different methods that have been used to measure radiographic angles in hallux valgus. A general literature search using relevant key words was undertaken using databases such as Medline, Embase, Cinahl and Cochrane Library. REVIEW FINDINGS AND DISCUSSION: The manual methods used are prone to errors. The reliability can be improved by using standardised radiographic technique and measurement technique using specific reference points. Computer-assisted methods using software, might improve reliability of measurements. Further studies are needed to assess if these methods are easy to use, and to compare different software's that are available. Specifically designed software for the foot might further improve the reliability of radiographic measurements in hallux valgus. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  7. Entrance surface dose measurements in mammography using thermoluminescence technique

    Energy Technology Data Exchange (ETDEWEB)

    Rivera, T. [Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada Unidad Legaria del IPM Av. Legaria 694, 11500 Mexico D.F. (Mexico); Vega C, H.R.; Manzanares A, E [Unidad Academica de Estudios Nucleares, Universidad Autonoma de Zacatecas, Apdo. Postal 336, 98000 Zacatecas (Mexico); Azorin, J. [Universidad Autonoma Metropolitana-lztapalapa, Av. San Rafael Atlixco 186, 09340 Mexico D.F. (Mexico); Gonzalez, P.R. [Instituto Nacional de Investigaciones Nucleares, Carretera Mexico Toluca, 52045 Salazar Estado de Mexico (Mexico)

    2007-07-01

    Full text: Of the various techniques that can be used for personnel dosimetry, thermoluminescence dosimetry (TLD) has emerged as a superior technique due to its manifold advantages over other methods of dose estimation. Various phosphors have been therefore investigated regarding their suitability for dosimetry. In this paper, a dosimetry system based on thermally stimulated luminescence (TSL) from zirconium oxide phosphors embedded in polytetrafluorethylene (ZrO{sub 2}+PTFE) was developed for entrance surface doses (ES) measurements in mammography. Small ZrO{sub 2} pellets of 5 mm in diameter and 0.8 mm in thickness were used. The reproducibility of measurements and linearity of ZrO{sub 2} were also studied. The results were compared with those obtained from LiF:Mg,Cu,P usually used for the determination of absorbed dose in mammography. Measurements both per unit air kerma and In vivo were performed using a mammography unit model DMR (General Electric). The results showed that ZrO{sub 2} TLDs can be used for the same X-ray dosimetry applications as LiF:Mg,Cu,P, with each type having the disadvantage of a response dependent on energy, particularly at low energies. These results indicate a considerable potential for use in routine control and In vivo ES measurements in mammography. (Author)

  8. Research on Pipeline Holdup Measurement Technology

    Institute of Scientific and Technical Information of China (English)

    LU; Wen-guang; XU; Zheng; CHENG; Yi-mei; SUI; Hong-zhi; YIN; Hong-he

    2012-01-01

    <正>Some of the nuclear material could be deposited in the pipeline system of the nuclear facilities in the operation process. That kind of nuclear materials in the pipeline are called holdup. The measurement of pipeline holdup is not only important for the nuclear material accounting and control of facilities, but also important for the safe operation of facilities.

  9. New Product Development: Can Technique Substitute for Technology?

    Science.gov (United States)

    Meyers, Barbara E.

    1984-01-01

    Overview of research techniques involved in gathering information on current products that can provide input into new product development highlights consumer purchase and use patterns. Comparison of mail questionnaires, telephone surveys, focus group sessions, and in-person interviews notes type of data, timing, relative costs, and advantages and…

  10. New technology - demonstration of a vector velocity technique

    DEFF Research Database (Denmark)

    Møller Hansen, Peter; Pedersen, Mads M; Hansen, Kristoffer L;

    2011-01-01

    With conventional Doppler ultrasound it is not possible to estimate direction and velocity of blood flow, when the angle of insonation exceeds 60-70°. Transverse oscillation is an angle independent vector velocity technique which is now implemented on a conventional ultrasound scanner. In this pa...

  11. Analog/RF Circuit Design Techniques for Nanometerscale IC Technologies

    NARCIS (Netherlands)

    Nauta, Bram; Annema, Anne-Johan

    2005-01-01

    CMOS evolution introduces several problems in analog design. Gate-leakage mismatch exceeds conventional matching tolerances requiring active cancellation techniques or alternative architectures. One strategy to deal with the use of lower supply voltages is to operate critical parts at higher supply

  12. New Product Development: Can Technique Substitute for Technology?

    Science.gov (United States)

    Meyers, Barbara E.

    1984-01-01

    Overview of research techniques involved in gathering information on current products that can provide input into new product development highlights consumer purchase and use patterns. Comparison of mail questionnaires, telephone surveys, focus group sessions, and in-person interviews notes type of data, timing, relative costs, and advantages and…

  13. Distance-Measuring Technology Using LD for Auto Anti-Collision

    Institute of Scientific and Technical Information of China (English)

    Zhang Xin-bao; Lu Hong; Li Zhu

    2004-01-01

    Auto anti-collision technology is one of the main research subjects of automobiles' safety technology. Aiming at the key technology of Auto anti-collision, measuring the distance from obstacles, based on the theory of phase laser distance ranging, Laser Diode (LD) distance-measuring system for auto anti-collision has been developed to solve the problem of on-line measuring distance technology in middle to long distance utilizing the good characteristics of LD when modulating its optical intensity and adopting typical kinds of filter techniques in this paper. By theoretical analysis, adopting typical kinds of filter techniques can reduce the interference of strong light, so distance-measuring range can be 0.5-100 m in daytime or 1-200 m at night. And more, from theoretical analysis and experiment result, it can guarantee the high measuring resolution which can be less than 24.5 mm, utilizing the method of two Laser Diode optical intensity modulating wavelength and complimenting precise calibration and revision. The idea of LD distance-measuring technology is novel and feasible and this technology can be applied in Auto anti-collision.

  14. Flowing dusty plasma experiments: generation of flow and measurement techniques

    Science.gov (United States)

    Jaiswal, S.; Bandyopadhyay, P.; Sen, A.

    2016-12-01

    A variety of experimental techniques for the generation of subsonic/supersonic dust fluid flows and means of measuring such flow velocities are presented. The experiments have been carried out in a \\Pi -shaped dusty plasma experimental device with micron size kaolin/melamine formaldehyde particles embedded in a background of argon plasma created by a direct current glow discharge. A stationary dust cloud is formed over the cathode region by precisely balancing the pumping speed and gas flow rate. A flow of dust particles/fluid is generated by additional gas injection from a single or dual locations or by altering the dust confining potential. The flow velocity is then estimated by three different techniques, namely, by super particle identification code, particle image velocimetry analysis and the excitation of dust acoustic waves. The results obtained from these three different techniques along with their merits and demerits are discussed. An estimation of the neutral drag force responsible for the generation as well as the attenuation of the dust fluid flow is made. These techniques can be usefully employed in laboratory devices to investigate linear and non-linear collective excitations in a flowing dusty plasma.

  15. Laboratory technique for quantitative thermal emissivity measurements of geological samples

    Indian Academy of Sciences (India)

    George Mathew; Archana Nair; T K Gundu Rao; Kanchan Pande

    2009-08-01

    Thermal infrared spectroscopy is a powerful technique for the compositional analysis of geological materials. The spectral feature in the mid-IR region is diagnostic of the mineralogy and spectral signatures of mixtures of minerals that add linearly, and therefore, can be used as an important tool to determine the mineralogy of rocks in the laboratory and remotely for planetary exploration. The greatest challenge in the emission measurement lies in the measurement of the weak thermal photons emitted from geological materials in a laboratory setup, and accurately records the temperature of the rock sample. The present work pertains to the details of a new Thermal Emission Spectrometer (TES) laboratory that has been developed under the ISRO Planetary Science and Exploration (PLANEX) programme, for emission related mineralogical investigations of planetary surfaces. The focus of the paper is on the acquisition and calibration technique for obtaining emissivity, and the deconvolution procedure to obtain the modal abundances of the thermal emission spectra in the range of 6–25 m using Fourier Transform Infrared (FTIR) spectroscopy. The basic technique is adopted from the work of Ruff et al (1997). This laboratory at the Department of Earth Sciences, IIT-Bombay is currently developing pure end mineral library of mineral particulates (> 65 m), and adding new end members to the existing ASU spectral library. The paper argues the need for considering Lunar Orbiter Thermal Emission Spectrometer (LOTES) for future Indian Moon mission programme (Chandrayan-II) to determine evidences of varied lithologies on the lunar surface.

  16. Aerosol measurement technique: demonstration at CO2 technology centre Mongstad

    NARCIS (Netherlands)

    Cazenove, T. de; Bouma, R.H.B.; Goetheer, E.L.V.; Os, P.J. van; Hamborg, E.S.

    2016-01-01

    There are two main routes for amine emission. The first one is connected to volatile amine emission. The second route is amine emission via aerosols. Recently, it has been observed that under certain conditions and at specific test locations significant aerosol formation and emission can occur. To d

  17. A Comparison of Stellar Elemental Abundance Techniques and Measurements

    CERN Document Server

    Hinkel, Natalie R; Pagano, Michael D; Desch, Steven J; Anbar, Ariel D; Adibekyan, Vardan; Blanco-Cuaresma, Sergi; Carlberg, Joleen K; Mena, Elisa Delgado; Liu, Fan; Nordlander, Thomas; Sousa, Sergio G; Korn, Andreas; Gruyters, Pieter; Heiter, Ulrike; Jofre, Paula; Santos, Nuno C; Soubiran, Caroline

    2016-01-01

    Stellar elemental abundances are important for understanding the fundamental properties of a star or stellar group, such as age and evolutionary history, as well as the composition of an orbiting planet. However, as abundance measurement techniques have progressed, there has been little standardization between individual methods and their comparisons. As a result, different stellar abundance procedures determine measurements that vary beyond quoted error for the same elements within the same stars (Hinkel et al. 2014). The purpose of this paper is to better understand the systematic variations between methods and offer recommendations for producing more accurate results in the future. We have invited a number of participants from around the world (Australia, Portugal, Sweden, Switzerland, and USA) to calculate ten element abundances (C, O, Na, Mg, Al, Si, Fe, Ni, Ba, and Eu) using the same stellar spectra for four stars (HD361, HD10700, HD121504, HD202206). Each group produced measurements for each of the sta...

  18. ONLINE GRINDING WHEEL WEAR COMPENSATION BY IMAGE BASED MEASURING TECHNIQUES

    Institute of Scientific and Technical Information of China (English)

    WAN Daping; HU Dejin; WU Qi; ZHANG Yonghong

    2006-01-01

    Automatic compensation of grinding wheel wear in dry grinding is accomplished by an image based online measurement method. A kind of PC-based charge-coupled device image recognition system is schemed out, which detects the topography changes of the grinding wheel surface. Profile data, which corresponds to the wear and the topography, is measured by using a digital image processing method. The grinding wheel wear is evaluated by analyzing the position deviation of the grinding wheel edge. The online wear compensation is achieved according to the measure results. The precise detection and automatic compensation system is integrated into an open structure CNC curve grinding machine. A practical application is carried out to fulfil the precision curve grinding. The experimental results confirm the benefits of the proposed techniques, and the online detection accuracy is less than 5 μm. The grinding machine provides higher precision according to the in-process grinding wheel error compensation.

  19. Velocity of detonation (VOD measurement techniques - practical approach

    Directory of Open Access Journals (Sweden)

    Aruna Dhanraj Tete

    2013-06-01

    Full Text Available Velocity of Detonation (VOD is an important measure characteristics parameter of explosive material. The performance of explosive invariably depends on the velocity of detonation. The power/ strength of explosive to cause fragmentation of the solid structure determine the efficiency of the Blast performed. It is an established fact that measuring velocity of detonation gives a good indication of the strength and hence the performance of the explosive. In this survey various VOD measurement techniques such as electric, nonelectric and fibre optic have been discussed. To aid the discussion some commercially available VOD meter comparison are also presented. After review of the existing units available commercially and study of their respective merits and demerits, feature of an ideal system is proposed. 

  20. Mapping public regulation measures for photovoltaic technologies

    DEFF Research Database (Denmark)

    Sperling, Karl; Mathiesen, Brian Vad; Hvelplund, Frede

    2011-01-01

    regulation measures to support PV development. Danish PV development is described briefly and the current Danish PV support scheme is presented and discussed in relation to some of the challenges of PV development. It is suggested that while Danish PV development seems ready to exit the demonstration phase...... and to enter the diffusion phase, the current net metering scheme may actually not be appropriate to facilitate such a transition....

  1. Precise measurement technique for the stable acoustic cavitation bubble

    Institute of Scientific and Technical Information of China (English)

    HUANG Wei; CHEN Weizhong; LIU Yanan; GAO Xianxian; JIANG Lian; XU Junfeng; ZHU Yifei

    2005-01-01

    Based on the periodic oscillation of the stable acoustic cavitation bubble, we present a precise measurement technique for the bubble evolution. This technique comprises the lighting engineering of pulsing laser beam whose phase can be digitally shifted, and the long distance microphotographics. We used a laser, an acousto-optic modulator, a pulse generator, and a long distance microscope. The evolution of a levitated bubble can be directly shown by a series of bubble's images at different phases. Numerical simulation in the framework of the Rayleigh-Plesset bubble dynamics well supported the experimental result, and the ambient radius of the bubble, an important parameter related to the mass of the gas inside the bubble, was obtained at the same time.

  2. Repeated High-Precision Gravity and GPS Measurement Techniques

    Science.gov (United States)

    Gettings, P.; Harris, R. N.; Allis, R.; Chapman, D. S.

    2003-12-01

    Repeated high-precision gravity and GPS measurements are becoming a common tool for tracking changes in subsurface reservoirs. Despite this, there is little literature which discusses measurement techniques and the expected errors. Our research has focused on improving measurement techniques to be applied to ground water and geothermal steam reservoirs, including quantifying the minimum error levels with modern equipment. We applied these methods in two studies: ground water monitoring of the southern Salt Lake valley, Utah, USA, and steam monitoring of The Geysers geothermal field, California, USA. Gravity measurements using modern relative high-precision meters, such as Scintrex CG-3Ms or L&R E series, can now be routinely made to an accuracy of 5 μ Gal. Such accuracy requires the use of time series analysis at each station, and non-linear instrument drift functions. Modern computerized meters are capable of internally storing a time series of measurements for each station; older meters can often be fitted to log such data to a field computer. This time series, typically of 10-15 minute duration in our work, can then be analyzed in several ways to produce stable estimates of the gravity reading. In particular, our research has emphasized using a weighted arithmetic average (for long occupations), or a Thiele extrapolation scheme (for shorter station occupations). Instrument drift is removed through a superposition of a linear long-term drift function, and an empirical staircase function formed from differences between repeated station occupations. To achieve high-accuracy GPS measurements while maximizing the number of field stations in a survey, rapid-static measurements are necessary. We have tested the effect of occupation time and processing schemes on the absolute accuracy of the resulting GPS position. Using a post-processing differential method with a fixed (but not necessarily continuous) base station within 15 km, positioning error of <4 cm vertical is

  3. Damage detection technique by measuring laser-based mechanical impedance

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyeonseok; Sohn, Hoon [Department of Civil and Environmental Engineering, Korea Advanced Institute of Science and Technology (Daehak-ro 291, Yuseong-gu, Daejeon 305-701) (Korea, Republic of)

    2014-02-18

    This study proposes a method for measurement of mechanical impedance using noncontact laser ultrasound. The measurement of mechanical impedance has been of great interest in nondestructive testing (NDT) or structural health monitoring (SHM) since mechanical impedance is sensitive even to small-sized structural defects. Conventional impedance measurements, however, have been based on electromechanical impedance (EMI) using contact-type piezoelectric transducers, which show deteriorated performances induced by the effects of a) Curie temperature limitations, b) electromagnetic interference (EMI), c) bonding layers and etc. This study aims to tackle the limitations of conventional EMI measurement by utilizing laser-based mechanical impedance (LMI) measurement. The LMI response, which is equivalent to a steady-state ultrasound response, is generated by shooting the pulse laser beam to the target structure, and is acquired by measuring the out-of-plane velocity using a laser vibrometer. The formation of the LMI response is observed through the thermo-mechanical finite element analysis. The feasibility of applying the LMI technique for damage detection is experimentally verified using a pipe specimen under high temperature environment.

  4. Announcing the 2013 Measurement Science and Technology Outstanding Paper Awards

    Science.gov (United States)

    Foss, John; Dewhurst, Richard; Yacoot, Andrew; Tadigadapa, Srinivas; Peters, Kara

    2014-07-01

    Since 1991, Measurement Science and Technology has awarded a Best Paper prize. The Editorial Board of this journal believe that such a prize is an opportunity to thank authors for submitting their work, and serves as an integral part of the on-going quality review of the journal. The current breadth of topical areas that are covered by MST has made it advisable to expand the recognition of excellent publications. Hence, since 2005 the Editorial Board have presented 'Outstanding Paper Awards'. This year awards were presented in the areas of Fluid Mechanics, Measurement Science, Precision Measurement, Sensors and Sensing Systems, and Optical and Laser-based Techniques. Although the categories mirror subject sections in the journal, the Editorial Board consider articles from all categories in the selection process. 2013 Award Winner—Fluid Mechanics Extraction of skin-friction fields from surface flow visualizations Tianshu Liu Department of Mechanical and Aerospace Engineering, Western Michigan University, Kalamazoo, MI 49008, USA The skin friction or wall shear stress, τ w, for a wall bounded turbulent flow is a quantity of fundamental importance. It is the basis for the wall unit, ν/u τ (kinematic viscosity/friction velocity: [τ w/ρ ]1/2), which establishes the intrinsic length scale in the flow. The selected paper [1] provides a comprehensive review of—and builds upon—prior techniques to obtain τ w values over an area of interest for flow past complex geometries. The quantities that can be measured by optical imaging are shown to be related to the skin friction by the optical flow equation, which in turn is solved numerically as an inverse problem via the variational approach. The paper provides a well defined set of guidelines for other investigators. Detailed examples of skin-friction measurements using luminescent oil films as well as temperature- and pressure-sensitive paints are presented. Quantitative uncertainty estimates are included in the

  5. Experimental measurements of the thermal conductivity of ash deposits: Part 1. Measurement technique

    Energy Technology Data Exchange (ETDEWEB)

    A. L. Robinson; S. G. Buckley; N. Yang; L. L. Baxter

    2000-04-01

    This paper describes a technique developed to make in situ, time-resolved measurements of the effective thermal conductivity of ash deposits formed under conditions that closely replicate those found in the convective pass of a commercial boiler. Since ash deposit thermal conductivity is thought to be strongly dependent on deposit microstructure, the technique is designed to minimize the disturbance of the natural deposit microstructure. Traditional techniques for measuring deposit thermal conductivity generally do not preserve the sample microstructure. Experiments are described that demonstrate the technique, quantify experimental uncertainty, and determine the thermal conductivity of highly porous, unsintered deposits. The average measured conductivity of loose, unsintered deposits is 0.14 {+-} 0.03 W/(m K), approximately midway between rational theoretical limits for deposit thermal conductivity.

  6. An Overview of Optical Character Recognition (OCR) Technology and Techniques.

    Science.gov (United States)

    1978-06-01

    using optico -electric filters. In practice, the choice of preprocessing techniques must necessarily be related to the recognition method. For example...inter- face), Recognition Unit and Operator Communication device. A brief description of each major system component including the Input Sensor follows...accomplish several types of mark- sensor recognition. Together, they are ’ capable of recognizing machine and handprinted data intermixed on the same line. .3

  7. Equipment and Experimental Technique For Temperature Measurements In Deep Boreholes

    Science.gov (United States)

    Khristoforov, A.

    The technique of temperature measurements is highly informative since any dynami- cal processes in the boreholes and in the vicinities are accompanied by thermal effects. Electronics and equipment for remote measurements in the boreholes are briefly dis- cussed in the report. It includes a deep instrument, cable winch and surface recording unit placed onboard a car. The temperature dependent frequency modulated signal is used in deep instrument. A cable of original construction was developed for chute-lift operations. It has a signal and power channel at the same time and play the depth me- ter. The surface recording unit includes power supply for deep instruments, receiver, frequency meter and indicator. A personal computer is used for the measurement nu- merical control. Energy for the electronics is supplied by a car battery. Self sufficiency and high accuracy are specialities of the equipment. Using the technique and equip- ment we made the experimental study of temperature in the boreholes of the East European platform, Middle Asia, West Siberia, Kamchatka and other regions. Most of our temperatures and temperature gradients have been used for mapping.

  8. Disruptive Innovation in Air Measurement Technology: Reality or Hype?

    Science.gov (United States)

    This presentation is a big picture overview on the changing state of air measurement technology in the world, with a focus on the introduction of low-cost sensors into the market place. The presentation discusses how these new technologies may be a case study in disruptive innov...

  9. Disruptive Innovation in Air Measurement Technology: Reality or Hype?

    Science.gov (United States)

    This presentation is a big picture overview on the changing state of air measurement technology in the world, with a focus on the introduction of low-cost sensors into the market place. The presentation discusses how these new technologies may be a case study in disruptive innov...

  10. Technology assessment of applied techniques for exploitation of geothermal energy

    Energy Technology Data Exchange (ETDEWEB)

    1977-04-01

    Studies were made to elucidate the effects of technological development of natural steam and hot water on the general social and industrial environments. These were followed by studies of enhanced methods for the forecasting of these impacts. The studies included assessments of actual conditions and the preparation of regional models, ranging from rural to urban-fringe situations. The economic implications of geothermal development in various regional situations are discussed, and the models developed provide for the integration of new data and their extrapolation to as yet uncertain situations.

  11. A Comparison of Stellar Elemental Abundance Techniques and Measurements

    Science.gov (United States)

    Hinkel, Natalie R.; Young, Patrick A.; Pagano, Michael D.; Desch, Steven J.; Anbar, Ariel D.; Adibekyan, Vardan; Blanco-Cuaresma, Sergi; Carlberg, Joleen K.; Delgado Mena, Elisa; Liu, Fan; Nordlander, Thomas; Sousa, Sergio G.; Korn, Andreas; Gruyters, Pieter; Heiter, Ulrike; Jofré, Paula; Santos, Nuno C.; Soubiran, Caroline

    2016-09-01

    Stellar elemental abundances are important for understanding the fundamental properties of a star or stellar group, such as age and evolutionary history, as well as the composition of an orbiting planet. However, as abundance measurement techniques have progressed, there has been little standardization between individual methods and their comparisons. As a result, different stellar abundance procedures determine measurements that vary beyond the quoted error for the same elements within the same stars. The purpose of this paper is to better understand the systematic variations between methods and offer recommendations for producing more accurate results in the future. We invited a number of participants from around the world (Australia, Portugal, Sweden, Switzerland, and the United States) to calculate 10 element abundances (C, O, Na, Mg, Al, Si, Fe, Ni, Ba, and Eu) using the same stellar spectra for four stars (HD 361, HD 10700, HD 121504, and HD 202206). Each group produced measurements for each star using (1) their own autonomous techniques, (2) standardized stellar parameters, (3) a standardized line list, and (4) both standardized parameters and a line list. We present the resulting stellar parameters, absolute abundances, and a metric of data similarity that quantifies the homogeneity of the data. We conclude that standardization of some kind, particularly stellar parameters, improves the consistency between methods. However, because results did not converge as more free parameters were standardized, it is clear there are inherent issues within the techniques that need to be reconciled. Therefore, we encourage more conversation and transparency within the community such that stellar abundance determinations can be reproducible as well as accurate and precise.

  12. Measurement Technology on 200 Liters Barrels of Radioactive Waste

    Institute of Scientific and Technical Information of China (English)

    BAI; Lei; SHAO; Jie-wen; LIU; Da-ming; LIU; Hong-bin; CHENG; Yi-mei; HE; Li-xia; ZHU; Li-qun

    2012-01-01

    <正>The measurement device on 200 liters barrel of radioactive waste is designed following the rule of orderly measurement automatically, by using the technology of non-destructive to measure the mass of radioactive waste produced from fuel cycle. Device objects as shown in Fig. 1, which consists of the

  13. Advanced Techniques for Power System Identification from Measured Data

    Energy Technology Data Exchange (ETDEWEB)

    Pierre, John W.; Wies, Richard; Trudnowski, Daniel

    2008-11-25

    Time-synchronized measurements provide rich information for estimating a power-system's electromechanical modal properties via advanced signal processing. This information is becoming critical for the improved operational reliability of interconnected grids. A given mode's properties are described by its frequency, damping, and shape. Modal frequencies and damping are useful indicators of power-system stress, usually declining with increased load or reduced grid capacity. Mode shape provides critical information for operational control actions. This project investigated many advanced techniques for power system identification from measured data focusing on mode frequency and damping ratio estimation. Investigators from the three universities coordinated their effort with Pacific Northwest National Laboratory (PNNL). Significant progress was made on developing appropriate techniques for system identification with confidence intervals and testing those techniques on field measured data and through simulation. Experimental data from the western area power system was provided by PNNL and Bonneville Power Administration (BPA) for both ambient conditions and for signal injection tests. Three large-scale tests were conducted for the western area in 2005 and 2006. Measured field PMU (Phasor Measurement Unit) data was provided to the three universities. A 19-machine simulation model was enhanced for testing the system identification algorithms. Extensive simulations were run with this model to test the performance of the algorithms. University of Wyoming researchers participated in four primary activities: (1) Block and adaptive processing techniques for mode estimation from ambient signals and probing signals, (2) confidence interval estimation, (3) probing signal design and injection method analysis, and (4) performance assessment and validation from simulated and field measured data. Subspace based methods have been use to improve previous results from block

  14. International Conference Automation : Challenges in Automation, Robotics and Measurement Techniques

    CERN Document Server

    Zieliński, Cezary; Kaliczyńska, Małgorzata

    2016-01-01

    This book presents the set of papers accepted for presentation at the International Conference Automation, held in Warsaw, 2-4 March of 2016. It presents the research results presented by top experts in the fields of industrial automation, control, robotics and measurement techniques. Each chapter presents a thorough analysis of a specific technical problem which is usually followed by numerical analysis, simulation, and description of results of implementation of the solution of a real world problem. The presented theoretical results, practical solutions and guidelines will be valuable for both researchers working in the area of engineering sciences and for practitioners solving industrial problems. .

  15. Advanced spherical near-field antenna measurement techniques

    DEFF Research Database (Denmark)

    Nielsen, Jeppe Majlund; Pivnenko, Sergey; Breinbjerg, Olav

    2011-01-01

    The DTU-ESA facility has since the 1980es provided highly accurate antenna radiation pattern measurements and gain calibration by use of the probe corrected spherical nearfield technique, both for ESA (the European Space Agency) and other customers and continues to do so. Recent years activities...... and showing the capabilities of each participating facility. A special campaign was carried out with the aim of establishing a reference radiation pattern for the DTU-ESA VAST-12 antenna. The on-ground calibration of the MIRAS space radiometer for ESA's SMOS mission was carried out at the DTU-ESA facility...

  16. Electrical conductivity measurements on silicate melts using the loop technique

    Science.gov (United States)

    Waff, H. S.

    1976-01-01

    A new method is described for measurement of the electrical conductivity of silicate melts under controlled oxygen partial pressure at temperatures to 1550 C. The melt samples are suspended as droplets on platinum-rhodium loops, minimizing iron loss from the melt due to alloying with platinum, and providing maximum surface exposure of the melt to the oxygen-buffering gas atmosphere. The latter provides extremely rapid equilibration of the melt with the imposed oxygen partial pressure. The loop technique involves a minimum of setup time and cost, provides reproducible results to within + or - 5% and is well suited to electrical conductivity studies on silicate melts containing redox cations.

  17. Cerebral blood oxygenation measurements in neonates with optoacoustic technique

    Science.gov (United States)

    Herrmann, Stephen; Petrov, Irene Y.; Petrov, Yuriy; Richardson, C. Joan; Fonseca, Rafael A.; Prough, Donald S.; Esenaliev, Rinat O.

    2017-03-01

    Cerebral hypoxia is a major contributor to neonatal/infant mortality and morbidity including severe neurological complications such as mental retardation, cerebral palsy, motor impairment, and epilepsy. Currently, no technology is capable of accurate monitoring of neonatal cerebral oxygenation. We proposed to use optoacoustics for this application by probing the superior sagittal sinus (SSS), a large central cerebral vein. We developed and built a multi-wavelength, optical parametric oscillator (OPO) and laser diode optoacoustic systems for measurement of SSS blood oxygenation in the reflection mode through open anterior or posterior fontanelles and in the transmission mode through the skull in the occipital area. In this paper we present results of initial tests of the laser diode system for neonatal cerebral oxygenation measurements. First, the system was tested in phantoms simulating neonatal SSS. Then, using the data obtained in the phantoms, we optimized the system's hardware and software and tested it in neonates admitted in the Neonatal Intensive Care Unit. The laser diode system was capable of detecting SSS signals in the reflection mode through the open anterior and posterior fontanelles as well as in the transmission mode through the skull with high signal-to-noise ratio. Using the signals measured at different wavelengths and algorithms developed for oxygenation measurements, the laser diode system provided real-time, continuous oxygenation monitoring with high precision at all these locations.

  18. Comparison of bone density measurement techniques: DXA and Archimedes' principle.

    Science.gov (United States)

    Keenan, M J; Hegsted, M; Jones, K L; Delany, J P; Kime, J C; Melancon, L E; Tulley, R T; Hong, K D

    1997-11-01

    The standard method for determination of density (g/cm3) of bones from small animals has been the application of Archimedes' principle. A recent development has been software for the determination of "density" (g/cm2) of small animal bones with dual-energy X-ray absorptiometry (DXA). We compared Archimedes' principle and DXA (Hologic QDR-2000) in the measurement of the densities of whole and hollowed femurs of 5- to 6-month-old retired female breeder rats. In an attempt to ensure detectable treatment differences, rats were used from a low-vitamin D Holtzman and a supplemental-vitamin D Sprague-Dawley colony. Whole femur densities were higher for supplemental-vitamin D colony rats than for low vitamin D rats using both techniques (Archimedes' principle, p Archimedes' principle than for DXA. Other variables such as femur ash weight and calcium content were also highly correlated to densities with both techniques. Hollowed femur density values were higher than whole femur values with Archimedes' principle but lower with DXA. Colony effects for hollowed femur densities were diminished with Archimedes' principle (p < 0.03) and eliminated with DXA (p < 0.53). Investigation of whole bones is more biologically relevant, and both techniques were effective in detecting differences between whole femurs from low-vitamin D and supplemental-vitamin D colony rats.

  19. Flowing dusty plasma experiments: Generation of flow and measurement techniques

    CERN Document Server

    Jaiswal, S; Sen, A

    2016-01-01

    A variety of experimental techniques for the generation of subsonic/supersonic dust fluid flows and means of measuring such flow velocities are presented. The experiments have been carried out in a $\\Pi-$shaped Dusty Plasma Experimental (DPEx) device with micron size kaolin/Melamine Formaldehyde (MF) particles embedded in a background of Argon plasma created by a direct current (DC) glow discharge. A stationary dust cloud is formed over the cathode region by precisely balancing the pumping speed and gas flow rate. A flow of dust particles/fluid is generated by additional gas injection from a single or dual locations or by altering the dust confining potential. The flow velocity is then estimated by three different techniques, namely, by super Particle Identification (sPIT) code, Particle Image Velocimetry (PIV) analysis and the excitation of Dust Acoustic Waves (DAWs). The results obtained from these three different techniques along with their merits and demerits are discussed. An estimation of the neutral dr...

  20. IR Drop Analysis and Its Reduction Techniques in Deep Submicron Technology

    Directory of Open Access Journals (Sweden)

    Vanpreet Kaur

    2015-01-01

    Full Text Available This paper presents a detailed conceptual analysis of IR Drop effect in deep submicron technologies and its reduction techniques. The IR Drop effect in power/ground network increases rapidly with technology scaling. This affects the timing of the design and hence the desired speed. It is shown that in present day designs, using well known reduction techniques such as wire sizing and decoupling capacitor insertion, may not be sufficient to limit the voltage fluctuations and hence, two more important methods such as selective glitch reduction technique and IR Drop reduction through combinational circuit partitioning are discussed and the issues related to all the techniques are revised.

  1. Improved technique for blood flow velocity measurement using Doppler effect

    Science.gov (United States)

    Valadares Oliveira, Eduardo J.; Nantes Button, Vera L. d. S.; Maia, Joaquim M.; Costa, Eduardo T.

    2002-04-01

    The Doppler velocimeter developed allows to determine the angle between the ultrasonic beam and the velocity vector of the flow, and to calculate the precise blood flow in a vessel. Four piezoelectric transducers constitute the Doppler velocimeter. Three of these transducers are positioned to form an equilateral triangle (base of a pyramid). When these transducers move simultaneously, backward or forward from the initial position, the emitted ultrasonic beams focalize on a position (peak of the pyramid) closer or farther from the transducers faces, according to the depth of the vessel where we intend to measure de flow. The angle between the transducers allows adjusting the height of this pyramid and the position of the focus (where the three beams meet). A forth transducer is used to determine the diameter of the vessel and monitor the position of the Doppler velocimeter relative to the vessel. Simulation results showed that with this technique is possible to accomplish precise measurement of blood flow.

  2. Development of radiation protection and measurement technology

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Si Young; Lee, T. Y.; Kim, J. L.; Kim, B. H.; Lee, B. J.; Chung, K. K.; Lee, K. C.; Chung, R. I.; Han, Y. D.; Kim, J. S.; Lee, H. S.; Kim, C. K.; Yoon, K. S.; Jeong, D. Y.; Yoon, S. C.; Yoon, Y. C.; Lee, S. Y.; Kim, J. S.; Seo, K. W. [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); Kim, J. K.; Lee, J. K. [Hanyang Univ., Seoul (Korea, Republic of)

    1997-07-01

    Reference X-, gamma, beta and neutron radiation fields complying with the ISO and ANSI standards have been established and evaluated to provide a basic technical support in national radiation protection dosimetry program and to provide calibration measurement devices. Personal dose evaluation algorithm has been developed with these reference radiation fields, which comply well with both domestic and the new ANSI N13.11, to evaluate accurate personal dose equivalents. A personal internal dosimetry algorithm which can estimate the intakes of radionuclides from the results of in vivo bioassay and the resulting internal doses has been developed and verified its performance. It was also evaluated to be equality excellent compared with those being used in foreign countries and used to make a computer code for internal dose evaluation which can be run with PC under the Windows environment. A BOMAB phantom for precise calibration of in vivo system has been also designed, fabricated and test-evaluated. Based on the ALARA concept of the optimization principle of radiation protection, a method for estimating the cost for radiation protection has been studied and an objective monetary cost of detriment due to radiation exposure, called {alpha} value ($/man-Sv) has been derived and proposed based on the Korean socio-economic situation and human risk factors to provide basic data for the radiation protection optimization study in Korea. (author). 100 refs., 104 tabs., 69 figs.

  3. Internationalizing undergraduate psychology education: Trends, techniques, and technologies.

    Science.gov (United States)

    Takooshian, Harold; Gielen, Uwe P; Plous, Scott; Rich, Grant J; Velayo, Richard S

    2016-01-01

    How can we best internationalize undergraduate psychology education in the United States and elsewhere? This question is more timely than ever, for at least 2 reasons: Within the United States, educators and students seek greater contact with psychology programs abroad, and outside the United States, psychology is growing apace, with educators and students in other nations often looking to U.S. curricula and practices as models. In this article, we outline international developments in undergraduate psychology education both in the United States and abroad, and analyze the dramatic rise of online courses and Internet-based technologies from an instructional and international point of view. Building on the recommendations of the 2005 APA Working Group on Internationalizing the Undergraduate Psychology Curriculum, we then advance 14 recommendations on internationalizing undergraduate psychology education--for students, faculty, and institutions.

  4. Comparisons between different techniques for measuring mass segregation

    CERN Document Server

    Parker, Richard J

    2015-01-01

    We examine the performance of four different methods which are used to measure mass segregation in star-forming regions: the radial variation of the mass function $\\mathcal{M}_{\\rm MF}$; the minimum spanning tree-based $\\Lambda_{\\rm MSR}$ method; the local surface density $\\Sigma_{\\rm LDR}$ method; and the $\\Omega_{\\rm GSR}$ technique, which isolates groups of stars and determines whether the most massive star in each group is more centrally concentrated than the average star. All four methods have been proposed in the literature as techniques for quantifying mass segregation, yet they routinely produce contradictory results as they do not all measure the same thing. We apply each method to synthetic star-forming regions to determine when and why they have shortcomings. When a star-forming region is smooth and centrally concentrated, all four methods correctly identify mass segregation when it is present. However, if the region is spatially substructured, the $\\Omega_{\\rm GSR}$ method fails because it arbitra...

  5. Atmospheric flow measurements using the PIV and HWA techniques

    Directory of Open Access Journals (Sweden)

    Luciana Bassi Marinho Pires

    2010-08-01

    Full Text Available Alcântara Space Center (ASC is the Brazilian gate to the space where rockets of different sizes are launched. At ASC there is a relative topographical variation, coastal cliff, which modifies the atmospheric boundary layer characteristics and can cause interference for operations of rockets. In the present work, a simplified model (mock-up was studied in a wind tunnel. A scale factor of 1:1000 was used and the atmospheric flow was measured using the hot wire anemometer (HWA and particle image velocimetry (PIV techniques. Using of HWA it was possible to calculate values of average wind speed and fluctuations in a set of points of the section of tests that representing the region of the ASC. Through these measures, other meteorological parameters that represent the atmospheric flow, such as the friction velocity (u*, the roughness length (z0 from the logarithmic profile and the alpha exponent (ɑ of the power law were calculated. With the use of the PIV´s technique, the streamlines and the vorticity fields were obtained and it was noticed that the vorticity generated downwind of the coastal cliff has a strong turbulence (vorticities around 2000 sˉ¹. A rectangular building (simulating the mobile integration tower was inserted at the mock-up and the downwind turbulence was similar to the one generated by the coastal cliff.

  6. Atmospheric NO2 concentration measurements using differential absorption lidar technique

    Science.gov (United States)

    Devara, P. C. S.; Raj, P. Ernest

    1992-02-01

    Using the Differential Absorption Lidar (DIAL) technique, two types of approaches, namely, reflection from retroreflector / topographic target and backscatter from atmosphere, are available for studying remotely the atmospheric NO2 concentration. The Argon ion lidar system at the Indian Institute of Tropical Meteorology (IITM), Pune, India has been used for the measurements by following both the path-averaged and range-resolved approaches. For the former, a topographic target (hill) is used for determining path-averaged surface concentration. In the latter, spectral properties of atmospheric attenuation is used for making range-resolved measurements in the surface layer. The results of the observations collected by following both approaches are presented. The average surface NO2 concentration was found to vary between 0.01 and 0.105 ppm and the range-resolved measurements exhibited higher values suggesting treatment of the lidar data for scattering and extinction effects due to atmospheric aerosols and air molecules, and atmospheric turbulence. Certain modifications that are suggested to the experimental set-up, data acquisition and analysis to improve the measurements are briefly described.

  7. Nonlinear ultrasonic measurements based on cross-correlation filtering techniques

    Science.gov (United States)

    Yee, Andrew; Stewart, Dylan; Bunget, Gheorghe; Kramer, Patrick; Farinholt, Kevin; Friedersdorf, Fritz; Pepi, Marc; Ghoshal, Anindya

    2017-02-01

    Cyclic loading of mechanical components promotes the formation of dislocation dipoles in metals, which can serve as precursors to crack nucleation and ultimately lead to failure. In the laboratory setting, an acoustic nonlinearity parameter has been assessed as an effective indicator for characterizing the progression of fatigue damage precursors. However, the need to use monochromatic waves of medium-to-high acoustic energy has presented a constraint, making it problematic for use in field applications. This paper presents a potential approach for field measurement of acoustic nonlinearity by using general purpose ultrasonic pulser-receivers. Nonlinear ultrasonic measurements during fatigue testing were analyzed by the using contact and immersion pulse-through method. A novel cross-correlation filtering technique was developed to extract the fundamental and higher harmonic waves from the signals. As in the case of the classic harmonic generation, the nonlinearity parameters of the second and third harmonics indicate a strong correlation with fatigue cycles. Consideration was given to potential nonlinearities in the measurement system, and tests have confirmed that measured second harmonic signals exhibit a linear dependence on the input signal strength, further affirming the conclusion that this parameter relates to damage precursor formation from cyclic loading.

  8. Rainbow technique for multi-parameter measurement of absorbing cylinder

    Institute of Scientific and Technical Information of China (English)

    Feihu Song; Chuanlong Xu; Shimin Wang

    2013-01-01

    Rainbow refractometry is widely used to measure the radius and real part of refractive index of a cylinder.However,studies on the detection of imaginary part of the refractive index with rainbow technique were scarce.This paper presents a new method for simultaneously measuring the radius,real and imaginary part of the refractive index of a cylinder,on the basis of the Airy theory and the Bouguer theory.The rainbows produced by the illuminated cylinder at a capillary exit are captured by a CCD camera in a labscale system,and then processed by the proposed method.Experimental results showed that the radius,real and imaginary part of the refractive index can be accurately determined when the SNR (signal to noise ratio) of the ripple structure is sufficiently high.However,the SNR of the ripple structure gradually decreases with decreasing scattering intensity of the cylinder,leading to larger measurement errors of the radius and real part of the refractive index.The relative error of the imaginary part of the refractive index derived from the measurement errors of the radius and real part of the refractive index,is less than 3.4%.

  9. Human factors multi-technique approach to teenage engagement in digital technologies health research

    OpenAIRE

    Lang, Alexandra R; Craven, Michael P; Atkinson, Sarah; Simons, Lucy; Cobb, Sue; Mazzola, Marco

    2016-01-01

    This chapter explores the use of multi-techniques for teenage HCI health research. Through four case studies we present information about adolescents as users of healthcare services and technologies, adolescent personal development and the human factors approaches through which teenagers have been involved in healthcare research projects. In each case study; comprising of the design or evaluation of a new digital technology for supporting health or well-being, the techniques used by researche...

  10. Physical Properties of Liquid Terbium Measured by Levitation Techniques

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    To understand the nature and behavior of rare earth metals in their liquid phases, accurate values of their physical properties are essential.However, to measure their physical properties, the samples should be maintained in liquid phases for prolonged time, and this raises a formidable challenge.This is mainly explained by their high melting temperatures (e.g., 1629 K for Tb), high vapor pressure, and the risk of melt contamination with a crucible or support.An electrostatic levitation furnace alleviated these difficulties and allowed the determination of density, surface tension, and viscosity of several metals above their melting temperature.Here, first, the levitation furnace facility and the noncontact diagnostic procedures were briefly discussed, followed by the explanation of their thermophysical property measurements over wide temperature ranges.The density was obtained using an ultraviolet-based imaging technique that allowed excellent illumination, even at elevated temperatures.Over the 1615 to 1880 K temperature span, the density measurements could be expressed as ρ(T)=7.84×103-0.47 (T-Tm) (kg·m-3) with Tm=1629 K, yielding a volume expansion coefficient α(T) =6.0×10-5 (K-1).In addition, the surface tension and the viscosity could be determined by inducing a drop oscillation to a molten sample.Using this technique, the surface tension data could be expressed as σ(T)=8.93×102-0.10 (T-Tm)(mN·m-1) and those for viscosity as η(T) =0.583 exp [4.1×104/(RT)] (MPa·s) over the 1690 to 1980 K temperature range.

  11. Method and System for Measuring Spinning YarnTension Using Image Measuring Technique

    Institute of Scientific and Technical Information of China (English)

    梅顺齐; 宋志峰; 张智明

    2004-01-01

    A non-contact method and system for measuring spinning yarn tension is developed using an image processing technique and based on the theory of yarn balloon dynamics. The theoretical basis of the measurement is the relationship among yarn tension, balloon shape, and spinning parameters. The yarn tension is determined according to the geometric parameters of the balloon, which are measured from an image of the balloon. The digital image is captured with a CCD sensor, and processed in a computer using a wavelet transform technique. A measuring system is developed, and experiments are carried out. The results show that the proposed non-contact method is effective in the on-line measurement of spinning yarn tension for improving the degree of automation of the spinning machine.

  12. An Operational Technology for Assimilating Lagrangian Data Based on Dynamical Systems Techniques

    Science.gov (United States)

    2016-06-07

    An Operational Technology for Assimilating Lagrangian Data Based on Dynamical Systems Techniques Christopher K. R. T. Jones Department of... technology for assimilating Lagrangian data. This new Lagrangian data assimilation platform is expected to be particularly effective in ocean regions where...COVERED 00-00-2006 to 00-00-2006 4. TITLE AND SUBTITLE An Operational Technology for Assimilating Lagrangian Data Based on Dynamical Systems

  13. Intelligent instruments for process measurement techniques (monitoring of sensors)

    Science.gov (United States)

    Bauer, B.; Hess, H. D.; Kalinski, J. R.; Leisenberg, W.; Marsch, D.

    1984-06-01

    Possibilities to extract redundant information of temperature sensors (resistance thermometers, thermocouples, semiconductor temperature sensors), and to find out which of the suggested redundancies are most suited for self controlled monitoring were investigated. Practical experience with equipment for process measurement techniques shows that sensor failures are five times more frequent than electronic malfunction. For resistance thermometers the measured values of the redundant information source (ac resistance) are too small (relative inductivity change 7 million). The information sources strain gage and propagation of ultrasonic waves are excluded because of physical properties in the sensor materials. Changes in the crystalline structure of thermocouples have the effect that there is no well defined relationship between thermoelectric voltage and the redundant information sources, resistance and coupled current impulses. A correlation of thermovoltage with these redundant values would yield a measurement uncertainty corresponding to more than + or - 50 K. Experiments with negative temperature coefficient sensors show that a failure is proceeded by a change in capacitance of the order of 0.1 pF.

  14. A laser speckle imaging technique for measuring tissue perfusion.

    Science.gov (United States)

    Forrester, Kevin R; Tulip, J; Leonard, C; Stewart, C; Bray, Robert C

    2004-11-01

    Laser Doppler imaging (LDI) has become a standard method for optical measurement of tissue perfusion, but is limited by low resolution and long measurement times. We have developed an analysis technique based on a laser speckle imaging method that generates rapid, high-resolution perfusion images. We have called it laser speckle perfusion imaging (LSPI). This paper investigates LSPI output and compares it to LDI using blood flow models designed to simulate human skin at various levels of pigmentation. Results show that LSPI parameters can be chosen such that the instrumentation exhibits a similar response to changes in red blood cell concentration (0.1%-5%, 200 microL/min) and velocity (0-800 microL/min, 1% concentration) and, given its higher resolution and quicker response time, could provide a significant advantage over LDI for some applications. Differences were observed in the LDI and LSPI response to tissue optical properties. LDI perfusion values increased with increasing tissue absorption, while LSPI perfusion values showed a slight decrease. This dependence is predictable, owing to the perfusion algorithms specific to each instrument, and, if properly compensated for, should not influence each instrument's ability to measure relative changes in tissue perfusion.

  15. Measuring verbal psychotherapeutic techniques – A systematic review of intervention characteristics and measures

    Directory of Open Access Journals (Sweden)

    Antje eGumz

    2015-11-01

    Full Text Available Language is one of the most important tools of psychotherapists. The working mechanisms of verbal therapeutic techniques, however, are still marginally understood. In part, this is due to the lack of a generally acknowledged typology as well as a gold standard for the assess-ment of verbal techniques, which limits the possibility of conducting studies focusing this topic. The present study reviews measures used in clinical research which assess directly ob-servable dimensions of verbal interventions in a reliable manner. All measures were evaluated with respect to their theoretical foundation, research goals, assessment modes, and various psychometric properties. A systematic search in databases (PubMed, PsycInfo, PsycArticles, PSYNDEX, Web of Science, Embase followed by an additional snowballing search cover-ing the years 1940-2013 yielded n=179 publications eligible for review. Within these publica-tions, 34 measures were identified showing great heterogeneity regarding the aspects under study. Only two measures reached the highest psychometric standards and can be recom-mended for clinical use without any reservation. Central problems include deficiencies in the systematization of techniques as well as their partly ambiguous and inconsistent definitions. To promote this field of research, it will be important to achieve a consensus concerning the terminology, conceptions and measures of verbal techniques.

  16. Telemetry Measurement of Selected Biological Signal Using Bluetooth Technology

    Directory of Open Access Journals (Sweden)

    Martin Cerny

    2005-01-01

    Full Text Available This work treats of using the Bluetooth technology in biomedical engineering. The Bluetooth is used for transmission of measured data from pulse oximeter, ECG and monitor of blood pressure. OEM modules realize the devices for pulse oximetry and ECG. Both these realized devices can communicate with computer by Bluetooth technology and standard serial link too. The realized system of measuring devices is very flexible and mobile, because the Bluetooth technology is used and accumulators can supply the realized devices. It is possible to measure other physical values converted to voltage, because the used OEM module for pulse oximetry include A/D converter. The part of this work is software visualisation of measured values to.

  17. Groundwork for the Concept of Technique in Education: Herbert Marcuse and Technological Society

    Science.gov (United States)

    Pierce, Clayton

    2006-01-01

    This article articulates the groundwork for a new understanding of the concept of technique through a critical engagement with Herbert Marcuse's critical theory of technology. To this end, it identifies and engages three expressions of technique in Marcuse's work: mimesis, reified labor, and the happy consciousness. It is argued that this mapping…

  18. Groundwork for the Concept of Technique in Education: Herbert Marcuse and Technological Society

    Science.gov (United States)

    Pierce, Clayton

    2006-01-01

    This article articulates the groundwork for a new understanding of the concept of technique through a critical engagement with Herbert Marcuse's critical theory of technology. To this end, it identifies and engages three expressions of technique in Marcuse's work: mimesis, reified labor, and the happy consciousness. It is argued that this mapping…

  19. Recent advances in automation, robotics and measuring techniques

    CERN Document Server

    Zieliński, Cezary; Kaliczyńska, Małgorzata

    2014-01-01

    This book presents the recent advances and developments in control, automation, robotics, and measuring techniques. It presents contributions of top experts in the fields, focused on both theory and industrial practice. The particular chapters present a deep analysis of a specific technical problem which is in general followed by a numerical analysis and simulation, and results of an implementation for the solution of a real world problem. The book presents the results of the International Conference AUTOMATION 2014 held 26 - 28 March, 2014 in Warsaw, Poland on Automation – Innovations and Future Prospectives The presented theoretical results, practical solutions and guidelines will be useful for both researchers working in the area of engineering sciences and for practitioners solving industrial problems.

  20. Advanced digital modulation: Communication techniques and monolithic GaAs technology

    Science.gov (United States)

    Wilson, S. G.; Oliver, J. D., Jr.; Kot, R. C.; Richards, C. R.

    1983-01-01

    Communications theory and practice are merged with state-of-the-art technology in IC fabrication, especially monolithic GaAs technology, to examine the general feasibility of a number of advanced technology digital transmission systems. Satellite-channel models with (1) superior throughput, perhaps 2 Gbps; (2) attractive weight and cost; and (3) high RF power and spectrum efficiency are discussed. Transmission techniques possessing reasonably simple architectures capable of monolithic fabrication at high speeds were surveyed. This included a review of amplitude/phase shift keying (APSK) techniques and the continuous-phase-modulation (CPM) methods, of which MSK represents the simplest case.

  1. Technological measures of protection in the copyright system

    Directory of Open Access Journals (Sweden)

    Radovanović Sanja

    2011-01-01

    Full Text Available Digital exploitation of works often exceed the limit to which the holder can control the exploitation of their intellectual creations, and the protection provided by legal norms are, in the era of a fast exchange of information, may prove to be insufficiently effective. For these reasons, the rights holders are increasingly opting for preventive care through placement of physical obstacles to the exploitation of copyright works, generic called technological protection measures (known as digital right management (DRM. Simultaneously with the development of the application of these measures flows the process of finding ways to circumvent them. Therefore, the effectiveness of technological measures depends on exactly the question of their legal protection, which now exists in most of modern legal systems. However, in the normative solutions there are differences, which reflect the problems in finding adequate forms of protection. They mostly stem from the fact that the sanctioning of circumvention (or preparatory actions of technological measures put into the question the purpose of copyright protection in general. Hence, in this paper we tried to point out the normative solutions accepted in modern legal systems and practical implications of what they have. Conclusion that arises is that the legal shaping of technological measures is not completed and that further technological developments open new dilemmas.

  2. Blood pressure measurement in hemodialysis: The importance of the measurement technique.

    Science.gov (United States)

    Kubrusly, M; de Oliveira, Claudia Maria Costa; Silva, R P; Pinheiro, M A; Rocha, M B C; Magalhães, R M

    2016-03-01

    Systemic arterial hypertension contributes to the high cardiovascular morbidity in hemodialysis (HD) patients, but the accuracy of blood pressure (BP) measurement in this population has not been well studied. To evaluate the agreement between BP measurement using the routine measurement technique (usual method) and the technique recommended by the VII Joint (standard method). This cross-sectional study enrolled 124 patients in a single center who had undergone dialysis for more than three months and were 18 years of age or older. The BP was verified at the start of dialysis by the nursing team (usual method) and by the researchers (standard method). The agreement between the systolic and diastolic BP (SBP and DBP) measurements was tested by the Bland-Altman analysis. A difference in BP measurement higher than ±5 mm Hg was considered clinically significant. The studied group had a mean age of 53.2 years. The average difference between routine and standard BP measurement was -6 mm Hg for SBP (limits of agreement: -40.1-28 mm Hg; P measured by both methods was observed in 69.4% of the patients for SBP and in 61.3% for DBP. The disagreement between the results of different BP measurement methods in HD patients was significant and the BP was underestimated using the usual BP method. BP measurement standardization should be encouraged to avoid errors in diagnosis and therapy.

  3. Continuous renal replacement therapy. Keeping pace with changes in technology and technique.

    Science.gov (United States)

    Baldwin, Ian

    2002-01-01

    The rapidly changing nature of new technologies and techniques in acute health care means it can be difficult keeping pace. Most facilities, large or small, are usually in continuous evaluation of a new technology. Published reviews and professional group guidelines can assist the process of change for continuous renal replacement therapy (CRRT) technologies and techniques. The current techniques and technologies are a mixed application of old and new technologies providing a combination of convective and diffusive solute clearance methods. There are a variety of anticoagulation approaches. New, purpose-built CRRT machines offer many advantages over old technology but their costs can be prohibitive and users do not always meet them with rapid behavioral change. Reading journal publications and texts, scientific meetings, education and training, Internet web site review/participation, quality improvement activities and an accurate local data base are the keys to keeping pace with changes and identifying whether a benefit can be anticipated and demonstrated. Possible changes for the future of techniques and technologies may be in the areas of modified approaches to continuous therapy with tailored approaches for specific patient care settings. Improved membrane characteristics for wider indications and the bio-artificial kidney are emerging along with blood pump and circuit design improvements, with new machine/operator interfaces.

  4. Noncontacting measurement technologies for space propulsion condition monitoring

    Science.gov (United States)

    Randall, M. R.; Barkhoudarian, S.; Collins, J. J.; Schwartzbart, A.

    1987-01-01

    This paper describes four noncontacting measurement technologies that can be used in a turbopump condition monitoring system. The isotope wear analyzer, fiberoptic deflectometer, brushless torque-meter, and fiberoptic pyrometer can be used to monitor component wear, bearing degradation, instantaneous shaft torque, and turbine blade cracking, respectively. A complete turbopump condition monitoring system including these four technologies could predict remaining component life, thus reducing engine operating costs and increasing reliability.

  5. A new technique for the solution of references problem in oil pollution measurement by UVF technique

    Directory of Open Access Journals (Sweden)

    Kasım Cemal Güven

    2016-09-01

    Full Text Available In this work, the problems of references used for oil pollution measurement by UVF method were discussed. The main problem of this method is that the origin of the reference for pollutant oil is unknown. The proposed solution for this problem was based on sea water sample which was taken from contaminated area, extracted by DCM, the organic phase was distilled, its calibration curve was plotted with this residue oil and measurement was made on its equation. The oil pollution results for the sea water of K0 station by using this equation for 2013 was 15.21 mg/L and for 2014 15.25 mg/L. for the same samples determination of oil pollution by using crude oil references varies between 0.11 and 1.15 various crude oils and using chrysene reference 0.11-0.19 mg/L. These results show that pollution level varied depending on references used. The proposed method more realistically determines the oil pollution level. The proposed technique is the first for oil pollution measurement by UVF.

  6. Trace element measurement in Saliva by NAA and PIXE techniques

    Energy Technology Data Exchange (ETDEWEB)

    Hamidian, M.R.; Vahid Golpayegani, M.; Shojai, S. (Shahid Beheshti Medical Science Univ., Shemiran, Tehran (Iran, Islamic Republic of))

    1993-01-01

    The activity of salivary glands and the chemical and physical properties of saliva, especially in some illnesses in which the activity of salivary glands and the chemical and physical properties alter, sometimes have severe effects on sedimentation and tooth decay. Long-standing investigations have shown the relationship between salivary gland activity and saliva composition in dental carries. Many modern techniques have been employed to measure important elements in saliva. The major elements in saliva include sodium, potassium, calcium, magnesium, chlorine, phosphorus, iodine, and fluorine. It should be pointed out that the amount of minerals changes when the diet changes. The major constituent of saliva is water with a density of 1.007 g/cm[sup 3] in which 0.6% is solid, 0.3% organic material and 0.3% inorganic material. In addition to other effects, the acidity (pH) of saliva has a strong effect on tooth sedimentation. Type of work, degree of stress, and mental condition affect salivary gland activity. When the acidity of salivary fluid in the mouth and consequently over the teeth drops, sedimentation increases. In this paper, the results of trace element measurement in saliva are presented.

  7. Measures of International Manufacturing and Trade of Clean Energy Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Engel-Cox, Jill; Sandor, Debbie; Keyser, David; Mann, Margaret

    2017-05-25

    The technologies that produce clean energy, such as solar photovoltaic panels and lithium ion batteries for electric vehicles, are globally manufactured and traded. As demand and deployment of these technologies grows exponentially, the innovation to reach significant economies of scale and drive down energy production costs becomes less in the technology and more in the manufacturing of the technology. Manufacturing innovations and other manufacturing decisions can reduce costs of labor, materials, equipment, operating costs, and transportation, across all the links in the supply chain. To better understand the manufacturing aspect of the clean energy economy, we have developed key metrics for systematically measuring and benchmarking international manufacturing of clean energy technologies. The metrics are: trade, market size, manufacturing value-added, and manufacturing capacity and production. These metrics were applied to twelve global economies and four representative technologies: wind turbine components, crystalline silicon solar photovoltaic modules, vehicle lithium ion battery cells, and light emitting diode packages for efficient lighting and other consumer products. The results indicated that clean energy technologies are being developed via complex, dynamic, and global supply chains, with individual economies benefiting from different technologies and links in the supply chain, through both domestic manufacturing and global trade.

  8. State-of-the-Art Sensor Technology in Spain: Invasive and Non-Invasive Techniques for Monitoring Respiratory Variables

    Directory of Open Access Journals (Sweden)

    Christian Domingo

    2010-05-01

    Full Text Available The interest in measuring physiological parameters (especially arterial blood gases has grown progressively in parallel to the development of new technologies. Physiological parameters were first measured invasively and at discrete time points; however, it was clearly desirable to measure them continuously and non-invasively. The development of intensive care units promoted the use of ventilators via oral intubation ventilators via oral intubation and mechanical respiratory variables were progressively studied. Later, the knowledge gained in the hospital was applied to out-of-hospital management. In the present paper we review the invasive and non-invasive techniques for monitoring respiratory variables.

  9. A review of hemorheology: Measuring techniques and recent advances

    Science.gov (United States)

    Sousa, Patrícia C.; Pinho, Fernando T.; Alves, Manuel A.; Oliveira, Mónica S. N.

    2016-02-01

    Significant progress has been made over the years on the topic of hemorheology, not only in terms of the development of more accurate and sophisticated techniques, but also in terms of understanding the phenomena associated with blood components, their interactions and impact upon blood properties. The rheological properties of blood are strongly dependent on the interactions and mechanical properties of red blood cells, and a variation of these properties can bring further insight into the human health state and can be an important parameter in clinical diagnosis. In this article, we provide both a reference for hemorheological research and a resource regarding the fundamental concepts in hemorheology. This review is aimed at those starting in the field of hemodynamics, where blood rheology plays a significant role, but also at those in search of the most up-to-date findings (both qualitative and quantitative) in hemorheological measurements and novel techniques used in this context, including technical advances under more extreme conditions such as in large amplitude oscillatory shear flow or under extensional flow, which impose large deformations comparable to those found in the microcirculatory system and in diseased vessels. Given the impressive rate of increase in the available knowledge on blood flow, this review is also intended to identify areas where current knowledge is still incomplete, and which have the potential for new, exciting and useful research. We also discuss the most important parameters that can lead to an alteration of blood rheology, and which as a consequence can have a significant impact on the normal physiological behavior of blood.

  10. Recent Investments by NASA's National Force Measurement Technology Capability

    Science.gov (United States)

    Commo, Sean A.; Ponder, Jonathan D.

    2016-01-01

    The National Force Measurement Technology Capability (NFMTC) is a nationwide partnership established in 2008 and sponsored by NASA's Aeronautics Evaluation and Test Capabilities (AETC) project to maintain and further develop force measurement capabilities. The NFMTC focuses on force measurement in wind tunnels and provides operational support in addition to conducting balance research. Based on force measurement capability challenges, strategic investments into research tasks are designed to meet the experimental requirements of current and future aerospace research programs and projects. This paper highlights recent and force measurement investments into several areas including recapitalizing the strain-gage balance inventory, developing balance best practices, improving calibration and facility capabilities, and researching potential technologies to advance balance capabilities.

  11. Temperature measurements at the National Institute of Standards and Technology

    Science.gov (United States)

    Mangum, B. W.

    The high-precision and high-accuracy measurements involved in the calibrations of various types of thermometers at the National Institute of Standards and Technology (NIST) are described. The responsibilities of the NIST Thermometry Group include not only calibration of the standard instruments of the scales but also the calibration of base-metal and noble-metal thermocouples, industrial platinum resistance thermometers, liquid in-glass thermometers, thermistor thermometers, and digital thermometers. General laboratory thermometer calibrations are described. Also, a Measurement Assurance Program is described which provides a direct assessment of a customer's technological competence in thermometry.

  12. Broadband Lidar Technique for Precision CO2 Measurement

    Science.gov (United States)

    Heaps, William S.

    2008-01-01

    Presented are preliminary experimental results, sensitivity measurements and discuss our new CO2 lidar system under development. The system is employing an erbium-doped fiber amplifier (EDFA), superluminescent light emitting diode (SLED) as a source and our previously developed Fabry-Perot interferometer subsystem as a detector part. Global measurement of carbon dioxide column with the aim of discovering and quantifying unknown sources and sinks has been a high priority for the last decade. The goal of Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) mission is to significantly enhance the understanding of the role of CO2 in the global carbon cycle. The National Academy of Sciences recommended in its decadal survey that NASA put in orbit a CO2 lidar to satisfy this long standing need. Existing passive sensors suffer from two shortcomings. Their measurement precision can be compromised by the path length uncertainties arising from scattering within the atmosphere. Also passive sensors using sunlight cannot observe the column at night. Both of these difficulties can be ameliorated by lidar techniques. Lidar systems present their own set of problems however. Temperature changes in the atmosphere alter the cross section for individual CO2 absorption features while the different atmospheric pressures encountered passing through the atmosphere broaden the absorption lines. Currently proposed lidars require multiple lasers operating at multiple wavelengths simultaneously in order to untangle these effects. The current goal is to develop an ultra precise, inexpensive new lidar system for precise column measurements of CO2 changes in the lower atmosphere that uses a Fabry-Perot interferometer based system as the detector portion of the instrument and replaces the narrow band laser commonly used in lidars with the newly available high power SLED as the source. This approach reduces the number of individual lasers used in the system from three or more

  13. The impact of information technology on productivity using structural equations technique in Iran Behnoush Company

    Directory of Open Access Journals (Sweden)

    Mina Beig

    2012-08-01

    Full Text Available Information technology plays an important role on increasing productivity in many organizations. The primary objective of the present survey is to study the impact of information technology on productivity and find a positive and significant relationship between these two factors. Structural equations technique and LISREL software are used for analysis of the questionnaires distributed among managers and some employees of Iran Behnoush Company. Organizations try to improve their performance by investment in information technology. However, many of the previous studies indicate insignificance of the impact of information technology on productivity of the organizations. The present survey studies the impact of information technology on organizations' productivity through the collected data from the above company. Results confirm existence of a positive relationship between information technology and productivity.

  14. An indirect time-of-flight measurement technique for sub-mm range resolution using impulse photocurrent response

    Science.gov (United States)

    Usui, Takahiro; Yasutomi, Keita; Man, Han San; Takasawa, Taishi; Kagawa, Keiichiro; Kawahito, Shoji

    2014-03-01

    This paper presents a new ToF measurement technique using an impulse photocurrent response. In the proposed technique, a laser with a short pulse width for light source, which can be regarded as an impulse input for a detector. As a result, the range calculation is determined only by photocurrent response of the detector. A test chip fabricated in a 0.11um CIS technology employs a draining-only modulation pixel, which enables a high speed charge modulation. The measurable range measured to be 50 mm within nonlinear error of 5% and the average range resolution of 0.21 mm is achieved.

  15. Diagnostic performance of MRI measurements to assess hindfoot malalignment. An assessment of four measurement techniques

    Energy Technology Data Exchange (ETDEWEB)

    Buck, Florian M.; Hoffmann, Adrienne; Mamisch-Saupe, Nadja; Hodler, Juerg [University Hospital Balgrist and University of Zurich, Radiology, Zuerich (Switzerland); Farshad, Mazda; Espinosa, Norman [University Hospital Balgrist and University of Zurich, Department of Orthopaedic Surgery, Zuerich (Switzerland); Resnick, Donald [University of California San Diego, Department of Radiology, San Diego, CA (United States)

    2013-09-15

    To investigate the ability of coronal non-weight-bearing MR images to discriminate between normal and abnormal hindfoot alignment. Three different measurement techniques (calcaneal axis, medial/lateral calcaneal contour) based on weight-bearing hindfoot alignment radiographs were applied in 49 patients (mean, 48 years; range 21-76 years). Three groups of subjects were enrolled: (1) normal hindfoot alignment (0 -10 valgus); (2) abnormal valgus (>10 ); (3) any degree of varus hindfoot alignment. Hindfoot alignment was then measured on coronal MR images using four different measurement techniques (calcaneal axis, medial/lateral calcaneal contour, sustentaculum tangent). ROC analysis was performed to find the MR measurement with the greatest sensitivity and specificity for discrimination between normal and abnormal hindfoot alignment. The most accurate measurement on MR images to detect abnormal hindfoot valgus was the one using the medial calcaneal contour, reaching a sensitivity/specificity of 86 %/75 % using a cutoff value of >11 valgus. The most accurate measurement on MR images to detect abnormal hindfoot varus was the sustentaculum tangent, reaching a sensitivity/specificity of 91 %/71 % using a cutoff value of <12 valgus. It is possible to suspect abnormal hindfoot alignment on coronal non-weight-bearing MR images. (orig.)

  16. Wireless Sensor for Measuring Pump Efficiency: Small Business Voucher Project with KCF Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Fugate, David L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Energy and Transportation Science Division; Liu, Xiaobing [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Energy and Transportation Science Division; Gehl, Anthony C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Energy and Transportation Science Division; Koopmann, Gary [KCF Technologies, State College, PA (United States)

    2017-01-23

    This document is to fulfill the final report requirements for the Small Business Voucher (SBV) CRADA project with ORNL and KCF Technologies (CRADA/NFE-16-06133). Pumping systems account for nearly 20% of the world’s electrical energy demand and range from 25-50% of the energy usage in many industrial and building power plants. The energy cost is the largest element in the total cost of owning a pump (~40%). In response to a recent DOE mandate for improved pump efficiency pump manufacturers are preparing for the changes that the impending regulations will bring, including design improvements. This mandate also establishes a need for new low cost pump efficiency measurement systems. The standard industry definition of pump efficiency is the mechanical water horsepower delivered divided by the electrical horsepower input to the motor. KCF Technologies has developed a new sensor measurement technique to estimate fluid pump efficiency using a thermodynamic approach. KCF Technologies applied for a SBV grant with ORNL as the research partner. KCF needed a research partner with the proper facilities to demonstrate the efficacy of its wireless sensor unit for measuring pump efficiency. The ORNL Building Technologies Research and Integration Center (BTRIC) test resources were used to test and demonstrate the successful measurement of pump efficiency with the KCF sensor technology. KCF is now working on next steps to commercialize this sensing technology.

  17. Measuring Information Technology Performance: Operational Efficiency and Operational Effectiveness

    Science.gov (United States)

    Moore, Annette G.

    2012-01-01

    This dissertation provides a practical approach for measuring operational efficiency and operational effectiveness for IT organizations introducing the ITIL process framework. The intent of the study was to assist Chief Information Officers (CIOs) in explaining the impact of introducing the Information Technology Infrastructure Library (ITIL)…

  18. GHG emission mitigation measures and technologies in the Czech Republic

    Energy Technology Data Exchange (ETDEWEB)

    Tichy, M. [Energy Efficiency Center, Prague (Czech Republic)

    1996-12-31

    The paper presents a short overview of main results in two fields: projection of GHG emission from energy sector in the Czech Republic and assessment of technologies and options for GHG mitigation. The last part presents an overview of measures that were prepared for potential inclusion to the Czech Climate Change Action Plan.

  19. Measuring Information and Communication Technology (ICT) Curriculum Integration

    Science.gov (United States)

    Proctor, Romina M. J.; Watson, Glenice; Finger, Glenn

    2004-01-01

    There is currently a trend toward the development of methodologies to measure Information and Communication Technology (ICT) curriculum integration and its resultant impact on student learning outcomes. Simplistic, negative correlations between numbers of classroom computers and standardized literacy and numeracy test results provide headlines for…

  20. Measuring Information Technology Performance: Operational Efficiency and Operational Effectiveness

    Science.gov (United States)

    Moore, Annette G.

    2012-01-01

    This dissertation provides a practical approach for measuring operational efficiency and operational effectiveness for IT organizations introducing the ITIL process framework. The intent of the study was to assist Chief Information Officers (CIOs) in explaining the impact of introducing the Information Technology Infrastructure Library (ITIL)…

  1. Analytic technique measures aromatics in soil and water

    Energy Technology Data Exchange (ETDEWEB)

    Roy, K.A.

    1990-12-01

    This paper reports on a technique for detecting aromatic compounds in soil and water. The technique traces its roots to a chemical reaction discovered in 1877. The reaction is an organic synthesis process that has been harnessed for the production of high-octane gasoline, synthetic rubber, plastics and synthetic detergents. More than a century later the same chemistry is used as the basis for an analytical technique that quantifies contamination caused by products.

  2. Measuring process performance within healthcare logistics - a decision tool for selecting measuring technologies

    DEFF Research Database (Denmark)

    Feibert, Diana Cordes; Jacobsen, Peter

    2015-01-01

    Performance measurement can support the organization in improving the efficiency and effectiveness of logistical healthcare processes. Selecting the most suitable technologies is important to ensure data validity. A case study of the hospital cleaning process at a public Danish hospital...

  3. Technology and geomorphology: Are improvements in data collection techniques transforming geomorphic science?

    Science.gov (United States)

    Viles, Heather

    2016-10-01

    In recent years technological developments have revolutionized our ability to collect data in geomorphology. Enhanced data collection not only enables us to provide deeper answers to a wider range of fundamental questions about the Earth's surface, but also encourages us to pose new questions. This paper considers in more detail the relationships between science, technology and the development of geomorphological tools and techniques, reviews the spectrum of tools and techniques now available to geomorphologists, and critically assesses what impact 'new technologies' are having on geomorphology. It focuses on the role of technology in biogeomorphology and weathering research, and how it is advancing theoretical, empirical and applied dimensions of these growing sub-fields of geomorphology. Five areas of important technological development are reviewed: remote sensing, dating, geophysical techniques, field and laboratory based analysis and sensing of physical and chemical characteristics, and field and laboratory based analysis of biological properties. There is good evidence that, taken together, technological developments are revolutionizing geomorphology through opening the doors to better cross-scalar investigations, blurring the boundaries between laboratory, field and computer model, and facilitating cross-disciplinary and democratized research.

  4. Relativistic quantum metrology: exploiting relativity to improve quantum measurement technologies.

    Science.gov (United States)

    Ahmadi, Mehdi; Bruschi, David Edward; Sabín, Carlos; Adesso, Gerardo; Fuentes, Ivette

    2014-05-22

    We present a framework for relativistic quantum metrology that is useful for both Earth-based and space-based technologies. Quantum metrology has been so far successfully applied to design precision instruments such as clocks and sensors which outperform classical devices by exploiting quantum properties. There are advanced plans to implement these and other quantum technologies in space, for instance Space-QUEST and Space Optical Clock projects intend to implement quantum communications and quantum clocks at regimes where relativity starts to kick in. However, typical setups do not take into account the effects of relativity on quantum properties. To include and exploit these effects, we introduce techniques for the application of metrology to quantum field theory. Quantum field theory properly incorporates quantum theory and relativity, in particular, at regimes where space-based experiments take place. This framework allows for high precision estimation of parameters that appear in quantum field theory including proper times and accelerations. Indeed, the techniques can be applied to develop a novel generation of relativistic quantum technologies for gravimeters, clocks and sensors. As an example, we present a high precision device which in principle improves the state-of-the-art in quantum accelerometers by exploiting relativistic effects.

  5. Measuring process performance within healthcare logistics - a decision tool for selecting measuring technologies

    DEFF Research Database (Denmark)

    Feibert, Diana Cordes; Jacobsen, Peter

    2015-01-01

    Performance measurement can support the organization in improving the efficiency and effectiveness of logistical healthcare processes. Selecting the most suitable technologies is important to ensure data validity. A case study of the hospital cleaning process at a public Danish hospital...... was conducted. Monitoring tasks and ascertaining quality of work is difficult in such a process. Based on principal-agent theory, a set of decision indicator has been developed, and a decision framework for assessing technologies to enable performance measurement has been proposed....

  6. A New Technique to Backup and Restore DBMS using XML and .NET Technologies

    CERN Document Server

    Kadry, Seifedine; Kassem, Hussam; Hayek, Hassan

    2011-01-01

    In this paper, we proposed a new technique for backing up and restoring different Database Management Systems (DBMS). The technique is enabling to backup and restore a part of or the whole database using a unified interface using ASP.NET and XML technologies. It presents a Web Solution allowing the administrators to do their jobs from everywhere, locally or remotely. To show the importance of our solution, we have taken two case studies, oracle 11g and SQL Server 2008.

  7. PREFACE: The 6th International Symposium on Measurement Techniques for Multiphase Flows

    Science.gov (United States)

    Okamoto, Koji; Murai, Yuichi

    2009-02-01

    Research on multi-phase flows is very important for industrial applications, including power stations, vehicles, engines, food processing, and so on. Also, from the environmental viewpoint, multi-phase flows need to be investigated to overcome global warming. Multi-phase flows originally have non-linear features because they are multi-phased. The interaction between the phases plays a very interesting role in the flows. The non-linear interaction causes the multi-phase flows to be very difficult to understand phenomena. The International Symposium on Measurement Techniques for Multi-phase Flows (ISMTMF) is a unique symposium. The target of the symposium is to exchange the state-of-the-art knowledge on the measurement techniques for non-linear multi-phase flows. Measurement technique is the key technology to understanding non-linear phenomena. The ISMTMF began in 1995 in Nanjing, China. The symposium has continuously been held every two or three years. The ISMTMF-2008 was held in Okinawa, Japan as the 6th symposium of ISMTMF on 15-17 December 2008. Okinawa has a long history as the Ryukyus Kingdom. China and Japan have had cultural and economic exchanges through Okinawa for more than 1000 years. Please enjoy Okinawa and experience its history to enhance our international communication. The present symposium was attended by 124 participants, the program included 107 contributions with 5 plenary lectures, 2 keynote lectures, and 100 oral regular paper presentations. The topics include, besides the ordinary measurement techniques for multiphase flows, acoustic and electric sensors, bubbles and microbubbles, computed tomography, gas-liquid interface, laser-imaging and PIV, oil/coal/drop and spray, solid and powder, spectral and multi-physics. This volume includes the presented papers at ISMTMF-2008. In addition to this volume, ten selected papers will be published in a special issue of Measurement Science and Technology. We would like to express special thanks to all

  8. THE USAGE OF TECHNOLOGIES IN TERRESTRIAL MEASUREMENTS FOR HAZARD MAPS

    Directory of Open Access Journals (Sweden)

    VELE Dan

    2015-06-01

    Full Text Available In the context of natural phenomena (earthquakes, floods, landslides etc. bring economical and social prejudices year by year, watching on them and taking decisions becomes mandatory for reducing the material and human lives loss. Making hazard maps represents a tool used on wide global scale but also particularly in our country. This paper work has the purpose to reveal the interests of certain authors related to the usage of the new technologies of terrestrial measurements (GPS technologies, photogrammetry, cartography and of remote sensing in order to make these hazard maps.

  9. The 1992 NASA Langley Measurement Technology Conference: Measurement Technology for Aerospace Applications in High-Temperature Environments

    Science.gov (United States)

    Singh, Jag J. (Editor); Antcliff, Richard R. (Editor)

    1992-01-01

    An intensive 2-day conference to discuss the current status of measurement technology in the areas of temperature/heat flux, stress/strain, pressure, and flowfield diagnostics for high temperature aerospace applications was held at Langley Research Center, Hampton, Virginia, on April 22 and 23, 1993. Complete texts of the papers presented at the Conference are included in these proceedings.

  10. Gear Damage Detection Integrating Oil Debris and Vibration Measurement Technologies Developed

    Science.gov (United States)

    Gyekeyeski, Andrew L.; Sawicki, Jerzy T.

    2001-01-01

    The development of highly reliable health-monitoring systems is one technology area recommended for reducing the number of helicopter accidents. Helicopter transmission diagnostics are an important part of a helicopter health-monitoring system because helicopters depend on the power train for propulsion, lift, and flight maneuvering. One technique currently being tested for increasing the reliability and decreasing the false alarm rate of current transmission diagnostic tools is the replacement of simple single-sensor limits with multisensor systems integrating different measurement technologies.

  11. Relativistic Quantum Metrology: Exploiting relativity to improve quantum measurement technologies

    CERN Document Server

    Ahmadi, Mehdi; Friis, Nicolai; Sabín, Carlos; Adesso, Gerardo; Fuentes, Ivette

    2013-01-01

    We present a framework for relativistic quantum metrology that is useful for both Earth-based and space-based technologies. Quantum metrology has been so far successfully applied to design precision instruments such as clocks and sensors which outperform classical devices by exploiting quantum properties. There are advanced plans to implement these and other quantum technologies in space, for instance Space-QUEST and Space Optical Clock projects intend to implement quantum communications and quantum clocks at regimes where relativity starts to kick in. However, typical setups do not take into account the effects of relativity on quantum properties. To include and exploit these effects, we introduce techniques for the application of metrology to quantum field theory (QFT). QFT properly incorporates quantum theory and relativity, in particular, at regimes where space-based experiments take place. This framework allows for high precision estimation of parameters that appear in QFT including proper times and acce...

  12. A new bridge technique for neutron tomography and diffraction measurements

    Energy Technology Data Exchange (ETDEWEB)

    Burca, G., E-mail: G.Burca@open.ac.uk [Materials Engineering, Open University, Milton Keynes, MK7 6AA (United Kingdom); James, J.A. [Materials Engineering, Open University, Milton Keynes, MK7 6AA (United Kingdom); Kockelmann, W. [ISIS Facility, STFC, Rutherford Appleton Laboratory, Chilton, OX11 0QX (United Kingdom); Fitzpatrick, M.E. [Materials Engineering, Open University, Milton Keynes, MK7 6AA (United Kingdom); Zhang, S.Y. [ISIS Facility, STFC, Rutherford Appleton Laboratory, Chilton, OX11 0QX (United Kingdom); Hovind, J. [Paul Scherrer Institute (PSI), CH-5232, Villigen (Switzerland); Langh, R. van [Delft University of Technology, Department of Materials Science, Faculty 3mE, Mekelweg 2, 2628 CD Delft (Netherlands); Rijksmuseum Amsterdam, P.O. Box 74888, 1070 DN Amsterdam (Netherlands)

    2011-09-21

    An attractive feature of neutron techniques is the ability to identify hidden materials and structures inside engineering components and objects of art and archaeology. Bearing this in mind we are investigating a new technique, 'Tomography Driven Diffraction' (TDD), that exploits tomography data to guide diffraction experiments on samples with complex structures and shapes. The technique can be used utilising combinations of individual tomography and diffraction instruments, such as NEUTRA (PSI, CH) and ENGIN-X (ISIS, UK), but is also suitable for new combined imaging and diffraction instruments such as the JEEP synchrotron engineering instrument (DIAMOND, UK) and the proposed IMAT neutron imaging and diffraction instrument (ISIS, UK).

  13. A New Technique for the Retrieval of Near Surface Water Vapor Using DIAL Measurements

    Science.gov (United States)

    Ismail, Syed; Kooi, Susan; Ferrare, Richard; Winker, David; Hair, Johnathan; Nehrir, Amin; Notari, Anthony; Hostetler, Chris

    2015-01-01

    Water vapor is one of the most important atmospheric trace gas species and influences radiation, climate, cloud formation, surface evaporation, precipitation, storm development, transport, dynamics, and chemistry. For improvements in NWP (numerical weather prediction) and climate studies, global water vapor measurements with higher accuracy and vertical resolution are needed than are currently available. Current satellite sensors are challenged to characterize the content and distribution of water vapor in the Boundary Layer (BL) and particularly near the first few hundred meters above the surface within the BL. These measurements are critically needed to infer surface evaporation rates in cloud formation and climate studies. The NASA Langley Research Center Lidar Atmospheric Sensing Experiment (LASE) system, which uses the Differential Absorption Lidar (DIAL) technique, has demonstrated the capability to provide high quality water vapor measurements in the BL and across the troposphere. A new retrieval technique is investigated to extend these DIAL water vapor measurements to the surface. This method uses signals from both atmospheric backscattering and the strong surface returns (even over low reflectivity oceanic surfaces) using multiple gain channels to cover the large signal dynamic range. Measurements can be made between broken clouds and in presence of optically thin cirrus. Examples of LASE measurements from a variety of conditions encountered during NASA hurricane field experiments over the Atlantic Ocean are presented. Comparisons of retrieved water vapor profiles from LASE near the surface with dropsonde measurements show very good agreement. This presentation also includes a discussion of the feasibility of developing space-based DIAL capability for high resolution water vapor measurements in the BL and above and an assessment of the technology needed for developing this capability.

  14. Ultrasonic crystallization monitoring technique for simultaneous in-line measurement of liquid and solid phase

    Science.gov (United States)

    Stelzer, T.; Pertig, D.; Ulrich, J.

    2013-01-01

    The mean crystal size, the suspension density and the liquid concentration are the three most important process parameters to quantify the progress of industrial crystallization processes. It will be shown that these parameters can be in-line monitored simultaneously by means of an ultrasonic crystallization monitoring technique (UCM), which will be introduced here in a proof of concept. This process analytical technology (PAT) differs from the known ultrasonic attenuation spectroscopy (UAS). For the UCM the ultrasonic velocity and attenuation were correlated and related to characteristic events during a crystallization process measured at only one frequency (no spectra of frequencies as it is used for UAS). The results shown in this study prepare the ground to establish the UCM as a simple, less complex, robust, universal applicable, inexpensive and, therefore, a winning alternative PAT to monitor and control in-line the solid as well as the liquid phase in the industrial crystallization by means of only one measuring device with two sensors.

  15. High-temperature strain measurement techniques: Current developments and challenges

    Science.gov (United States)

    Lemcoe, M. M.

    1992-01-01

    Since 1987, a very substantial amount of R&D has been conducted in an attempt to develop reliable strain sensors for the measurements of structural strains during ground testing and hypersonic flight, at temperatures up to at least 2000 deg F. Much of the effort has been focused on requirements of the NASP Program. This presentation is limited to the current sensor development work and characterization studies carried out within that program. It is basically an assessment as to where we are now and what remains to be done in the way of technical accomplishments to meet the technical challenges posed by the requirements and constraints established for the NASP Program. The approach for meeting those requirements and constraints has been multi-disciplinary in nature. It was recognized early on that no one sensor could meet all these requirements and constraints, largely because of the large temperature range (cryogenic to at least 2000 deg F) and many other factors, including the most challenging requirement that the sensor system be capable of obtaining valid 'first cycle data'. Present candidate alloys for resistance-type strain gages include Fe-Cr-Al and Pd-Cr. Although they have superior properties regarding withstanding very high temperatures, they exhibit large apparent strains that must either be accounted for or cancelled out by various techniques, including the use of a dual-element, half-bridge dummy gage, or electrical compensation networks. A significant effort is being devoted to developing, refining, and evaluating the effectiveness of those techniques over a broad range in temperature and time. In the quest to obtain first-cycle data, ways must be found to eliminate the need to prestabilize or precondition the strain gage, before it is attached to the test article. It should be noted that present NASP constraints do not permit prestabilization of the sensor, in situ. Gages are currently being 'heat treated' during manufacture in both the wire- and foil

  16. A Methodological Evaluation of Volumetric Measurement Techniques including Three-Dimensional Imaging in Breast Surgery

    Directory of Open Access Journals (Sweden)

    H. Hoeffelin

    2014-01-01

    Full Text Available Breast surgery currently remains very subjective and each intervention depends on the ability and experience of the operator. To date, no objective measurement of this anatomical region can codify surgery. In this light, we wanted to compare and validate a new technique for 3D scanning (LifeViz 3D and its clinical application. We tested the use of the 3D LifeViz system (Quantificare to perform volumetric calculations in various settings (in situ in cadaveric dissection, of control prostheses, and in clinical patients and we compared this system to other techniques (CT scanning and Archimedes’ principle under the same conditions. We were able to identify the benefits (feasibility, safety, portability, and low patient stress and limitations (underestimation of the in situ volume, subjectivity of contouring, and patient selection of the LifeViz 3D system, concluding that the results are comparable with other measurement techniques. The prospects of this technology seem promising in numerous applications in clinical practice to limit the subjectivity of breast surgery.

  17. A methodological evaluation of volumetric measurement techniques including three-dimensional imaging in breast surgery.

    Science.gov (United States)

    Hoeffelin, H; Jacquemin, D; Defaweux, V; Nizet, J L

    2014-01-01

    Breast surgery currently remains very subjective and each intervention depends on the ability and experience of the operator. To date, no objective measurement of this anatomical region can codify surgery. In this light, we wanted to compare and validate a new technique for 3D scanning (LifeViz 3D) and its clinical application. We tested the use of the 3D LifeViz system (Quantificare) to perform volumetric calculations in various settings (in situ in cadaveric dissection, of control prostheses, and in clinical patients) and we compared this system to other techniques (CT scanning and Archimedes' principle) under the same conditions. We were able to identify the benefits (feasibility, safety, portability, and low patient stress) and limitations (underestimation of the in situ volume, subjectivity of contouring, and patient selection) of the LifeViz 3D system, concluding that the results are comparable with other measurement techniques. The prospects of this technology seem promising in numerous applications in clinical practice to limit the subjectivity of breast surgery.

  18. Blood flow rate measurements with indicator techniques revisited

    DEFF Research Database (Denmark)

    Sejrsen, Per; Bülow, Jens

    2009-01-01

    In view of the emerging role, disturbances in regional blood flow rate seem to play in the pathogenesis of the metabolic syndrome; we review the concepts of the classical indicator dilution and washout techniques used for determinations of regional blood flow rate. Prerequisites, assumptions......, necessary precautions for the application of these experimental techniques are emphasized. Special attention has been carried out to elucidate the consequence of a choice of indicators having a large distribution volume in the tissues....

  19. Just-in-Time Teaching Techniques through Web Technologies for Vocational Students' Reading and Writing Abilities

    Science.gov (United States)

    Chantoem, Rewadee; Rattanavich, Saowalak

    2016-01-01

    This research compares the English language achievements of vocational students, their reading and writing abilities, and their attitudes towards learning English taught with just-in-time teaching techniques through web technologies and conventional methods. The experimental and control groups were formed, a randomized true control group…

  20. The Using of the Teaching Methods and Techniques by Science and Technology Teachers and Class Teachers

    Directory of Open Access Journals (Sweden)

    Tohit Gunesa

    2012-04-01

    Full Text Available The purpose of this study is to determine which teaching strategies, techniques and methods are used by teachers in science and technology classes and also to determine the shortcomings they have. A questionnaire was conducted to a total of 95 teachers, 45 of whom were science and technology teachers and 50 of whom were class teachers, and 33 teachers were interviewed. It was found out that the teachers did not have enough information about teaching strategies, methods and techniques and thus were not able to make a precise distinction between them. It was determined that although the teachers were aware that the most convenient teaching technique is experiment technique, they used direct instruction or question and answer technique more and they sometimes used methods and techniques such as laboratory, trip-observation and drama. It was stated that the teachers were not able to implement teaching methods and techniques in which the students could actively participate due to reasons such as insufficient time, intensive curriculum and overcrowded classes. It was also determined that the teachers who were not able to practice different teaching methods although they knew how useful they were needed in-service training.

  1. Advanced radiation measurement techniques in diagnostic radiology and molecular imaging.

    Science.gov (United States)

    Del Guerra, Alberto; Belcari, Nicola; Llacer, Gabriela Llosa; Marcatili, Sara; Moehrs, Sascha; Panetta, Daniele

    2008-01-01

    This paper reports some technological advances recently achieved in the fields of micro-CT and small animal PET instrumentation. It highlights a balance between image-quality improvement and dose reduction. Most of the recent accomplishments in these fields are due to the use of novel imaging sensors such as CMOS-based X-ray detectors and silicon photomultipliers (SiPM). Some of the research projects carried out at the University of Pisa for the development of such advanced radiation imaging technology are also described.

  2. 3D-Laser-Scanning Technique Applied to Bulk Density Measurements of Apollo Lunar Samples

    Science.gov (United States)

    Macke, R. J.; Kent, J. J.; Kiefer, W. S.; Britt, D. T.

    2015-01-01

    In order to better interpret gravimetric data from orbiters such as GRAIL and LRO to understand the subsurface composition and structure of the lunar crust, it is import to have a reliable database of the density and porosity of lunar materials. To this end, we have been surveying these physical properties in both lunar meteorites and Apollo lunar samples. To measure porosity, both grain density and bulk density are required. For bulk density, our group has historically utilized sub-mm bead immersion techniques extensively, though several factors have made this technique problematic for our work with Apollo samples. Samples allocated for measurement are often smaller than optimal for the technique, leading to large error bars. Also, for some samples we were required to use pure alumina beads instead of our usual glass beads. The alumina beads were subject to undesirable static effects, producing unreliable results. Other investigators have tested the use of 3d laser scanners on meteorites for measuring bulk volumes. Early work, though promising, was plagued with difficulties including poor response on dark or reflective surfaces, difficulty reproducing sharp edges, and large processing time for producing shape models. Due to progress in technology, however, laser scanners have improved considerably in recent years. We tested this technique on 27 lunar samples in the Apollo collection using a scanner at NASA Johnson Space Center. We found it to be reliable and more precise than beads, with the added benefit that it involves no direct contact with the sample, enabling the study of particularly friable samples for which bead immersion is not possible

  3. Measuring Public Acceptance of Nuclear Technology with Big data

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Seugkook [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    Surveys can be conducted only on people in specific region and time interval, and it may be misleading to generalize the results to represent the attitude of the public. For example, opinions of a person living in metropolitan area, far from the dangers of nuclear reactors and enjoying cheap electricity produced by the reactors, and a person living in proximity of nuclear power plants, subject to tremendous damage should nuclear meltdown occur, certainly differs for the topic of nuclear generation. To conclude, big data is a useful tool to measure the public acceptance of nuclear technology efficiently (i.e., saves cost, time, and effort of measurement and analysis) and this research was able to provide a case for using big data to analyze public acceptance of nuclear technology. Finally, the analysis identified opinion leaders, which allows target-marketing when policy is executed.

  4. GUIDELESS SPATIAL COORDINATE MEASUREMENT TECHNOLOGY BASED ON CODING POLE

    Institute of Scientific and Technical Information of China (English)

    ZHAO Min; QIU Zongming; QU Jiamin; LIU Hongzhao

    2008-01-01

    A new method of guideless spatial coordinate measurement technology based on coding pole and vision measurement is proposed. Unequal spacing of bar code is adopted to pole, so that the code combination of pole image in measuring field is unique. Holographic characteristics of numeric coding pole are adopted to obtain pole pose and pole probe position by any section of bar code on the pole. Spatial coordinates of measuring points can be obtained by coordinate transform. The contradiction between high resolution and large visual field of image sensor is resolved, thereby providing a new concept for surface shape measurement of large objects with high precision. The measurement principles of the system are expounded and mathematic model is established. The measurement equation is evaluated by simulation experiments and the measurement precision is analyzed. Theoretical analysis and simulation experiments prove that this system is characterized by simple structure and wide measurement range. Therefore it can be used in the 3-dimentional coordinate measurement of large objects.

  5. Technology and Technique Standards for Camera-Acquired Digital Dermatologic Images: A Systematic Review.

    Science.gov (United States)

    Quigley, Elizabeth A; Tokay, Barbara A; Jewell, Sarah T; Marchetti, Michael A; Halpern, Allan C

    2015-08-01

    Photographs are invaluable dermatologic diagnostic, management, research, teaching, and documentation tools. Digital Imaging and Communications in Medicine (DICOM) standards exist for many types of digital medical images, but there are no DICOM standards for camera-acquired dermatologic images to date. To identify and describe existing or proposed technology and technique standards for camera-acquired dermatologic images in the scientific literature. Systematic searches of the PubMed, EMBASE, and Cochrane databases were performed in January 2013 using photography and digital imaging, standardization, and medical specialty and medical illustration search terms and augmented by a gray literature search of 14 websites using Google. Two reviewers independently screened titles of 7371 unique publications, followed by 3 sequential full-text reviews, leading to the selection of 49 publications with the most recent (1985-2013) or detailed description of technology or technique standards related to the acquisition or use of images of skin disease (or related conditions). No universally accepted existing technology or technique standards for camera-based digital images in dermatology were identified. Recommendations are summarized for technology imaging standards, including spatial resolution, color resolution, reproduction (magnification) ratios, postacquisition image processing, color calibration, compression, output, archiving and storage, and security during storage and transmission. Recommendations are also summarized for technique imaging standards, including environmental conditions (lighting, background, and camera position), patient pose and standard view sets, and patient consent, privacy, and confidentiality. Proposed standards for specific-use cases in total body photography, teledermatology, and dermoscopy are described. The literature is replete with descriptions of obtaining photographs of skin disease, but universal imaging standards have not been developed

  6. Systematic and Statistical Errors Associated with Nuclear Decay Constant Measurements Using the Counting Technique

    Science.gov (United States)

    Koltick, David; Wang, Haoyu; Liu, Shih-Chieh; Heim, Jordan; Nistor, Jonathan

    2016-03-01

    Typical nuclear decay constants are measured at the accuracy level of 10-2. There are numerous reasons: tests of unconventional theories, dating of materials, and long term inventory evolution which require decay constants accuracy at a level of 10-4 to 10-5. The statistical and systematic errors associated with precision measurements of decays using the counting technique are presented. Precision requires high count rates, which introduces time dependent dead time and pile-up corrections. An approach to overcome these issues is presented by continuous recording of the detector current. Other systematic corrections include, the time dependent dead time due to background radiation, control of target motion and radiation flight path variation due to environmental conditions, and the time dependent effects caused by scattered events are presented. The incorporation of blind experimental techniques can help make measurement independent of past results. A spectrometer design and data analysis is reviewed that can accomplish these goals. The author would like to thank TechSource, Inc. and Advanced Physics Technologies, LLC. for their support in this work.

  7. WD-XRA technique in multiphase flow measuring

    Energy Technology Data Exchange (ETDEWEB)

    Gogolev, A.S.; Cherepennikov, Yu.M.; Vukolov, A.V. [Tomsk Polytechnic University, Lenin Avenue 30, Tomsk 634050 (Russian Federation); Rezaev, R.O. [Tomsk Polytechnic University, Lenin Avenue 30, Tomsk 634050 (Russian Federation); Nuclear University MEPhI, Kashirskoye Shosse 31, Moscow 115409 (Russian Federation); Stuchebrov, S.G. [Tomsk Polytechnic University, Lenin Avenue 30, Tomsk 634050 (Russian Federation); Hampai, D. [INFN Laboratori Nazionali di Frascati, Via E. Fermi 40, 00044 Frascati (Italy); Dabagov, S.B. [INFN Laboratori Nazionali di Frascati, Via E. Fermi 40, 00044 Frascati (Italy); Nuclear University MEPhI, Kashirskoye Shosse 31, Moscow 115409 (Russian Federation); RAS P.N. Lebedev Physical Institute, Lenin Avenue 53, Moscow 119991 (Russian Federation); Liedl, A.; Polese, C. [INFN Laboratori Nazionali di Frascati, Via E. Fermi 40, 00044 Frascati (Italy)

    2015-07-15

    A new technique to perform the analysis of multiphase fluid flow based on wave dispersive X-ray absorptiometry is suggested. The numerical simulation and comparison of this technique with currently used approaches are provided and a way to increase the luminosity intensity is found that includes the usage the X-ray focusing optics by a bent crystal and a polycapillary semilens. Based on numerical simulation of radiation spectrum the influence of the bent crystal on the luminosity is evaluated and experimentally shown the advantages of using the multicapillary optics.

  8. WD-XRA technique in multiphase flow measuring

    Science.gov (United States)

    Gogolev, A. S.; Cherepennikov, Yu. M.; Vukolov, A. V.; Rezaev, R. O.; Stuchebrov, S. G.; Hampai, D.; Dabagov, S. B.; Liedl, A.; Polese, C.

    2015-07-01

    A new technique to perform the analysis of multiphase fluid flow based on wave dispersive X-ray absorptiometry is suggested. The numerical simulation and comparison of this technique with currently used approaches are provided and a way to increase the luminosity intensity is found that includes the usage the X-ray focusing optics by a bent crystal and a polycapillary semilens. Based on numerical simulation of radiation spectrum the influence of the bent crystal on the luminosity is evaluated and experimentally shown the advantages of using the multicapillary optics.

  9. Development of a real-time aeroperformance analysis technique for the X-29A advanced technology demonstrator

    Science.gov (United States)

    Ray, R. J.; Hicks, J. W.; Alexander, R. I.

    1988-01-01

    The X-29A advanced technology demonstrator has shown the practicality and advantages of the capability to compute and display, in real time, aeroperformance flight results. This capability includes the calculation of the in-flight measured drag polar, lift curve, and aircraft specific excess power. From these elements many other types of aeroperformance measurements can be computed and analyzed. The technique can be used to give an immediate postmaneuver assessment of data quality and maneuver technique, thus increasing the productivity of a flight program. A key element of this new method was the concurrent development of a real-time in-flight net thrust algorithm, based on the simplified gross thrust method. This net thrust algorithm allows for the direct calculation of total aircraft drag.

  10. Research on the development of green chemistry technology assessment techniques: a material reutilization case

    Science.gov (United States)

    Hong, Seokpyo; Ahn, Kilsoo; Kim, Sungjune; Gong, Sungyong

    2015-01-01

    Objectives This study presents a methodology that enables a quantitative assessment of green chemistry technologies. Methods The study carries out a quantitative evaluation of a particular case of material reutilization by calculating the level of “greenness” i.e., the level of compliance with the principles of green chemistry that was achieved by implementing a green chemistry technology. Results The results indicate that the greenness level was enhanced by 42% compared to the pre-improvement level, thus demonstrating the economic feasibility of green chemistry. Conclusions The assessment technique established in this study will serve as a useful reference for setting the direction of industry-level and government-level technological R&D and for evaluating newly developed technologies, which can greatly contribute toward gaining a competitive advantage in the global market. PMID:26206363

  11. Research on the development of green chemistry technology assessment techniques: a material reutilization case.

    Science.gov (United States)

    Hong, Seokpyo; Ahn, Kilsoo; Kim, Sungjune; Gong, Sungyong

    2015-01-01

    This study presents a methodology that enables a quantitative assessment of green chemistry technologies. The study carries out a quantitative evaluation of a particular case of material reutilization by calculating the level of "greenness" i.e., the level of compliance with the principles of green chemistry that was achieved by implementing a green chemistry technology. The results indicate that the greenness level was enhanced by 42% compared to the pre-improvement level, thus demonstrating the economic feasibility of green chemistry. The assessment technique established in this study will serve as a useful reference for setting the direction of industry-level and government-level technological R&D and for evaluating newly developed technologies, which can greatly contribute toward gaining a competitive advantage in the global market.

  12. Viable behavioural and technological energy-saving measures

    Energy Technology Data Exchange (ETDEWEB)

    Poortinga, W. [Centre for Environmental Risk, University of East Anglia, Norwich (United Kingdom); Steg, L. [Department of Psychology, University of Groningen, Groningen (Netherlands)

    2002-07-01

    Both in the natural and social sciences sustainable household consumption has been studied for a long time. However, cooperation between the two has been fairly uncommon. This paper argues that the disciplines should collaborate closely in designing more successful environmental policies on household energy use. It demonstrates how data from the natural and social sciences may be combined to identify energy saving measures that are most likely to be successful, i.e., effective and acceptable (so-called viable energy-saving measures). Moreover, this study examined differences in acceptability of energy-saving measures between various socio-demographic groups. Differences in acceptability of behavioural and technological measures proved attributable not only to levels of environmental concern, but also to differences in income.

  13. Optical Measurement System for Motion Characterization of Surface Mount Technology

    Institute of Scientific and Technical Information of China (English)

    LI Song; AN Bing; ZHANG Tong-jun; XIE Yong-jun

    2006-01-01

    Advanced testing methods for the dynamics of mechanical microdevices are necessary to develop reliable,marketable microelectromechanical systems. A system for measuring the nanometer motions of microscopic structures has been demonstrated. Stop-action images of a target have been obtained with computer microvision,microscopic interferometry,and stroboscopic illuminator. It can be developed for measuring the in-plane-rigid-body motions,surface shapes,out-of-plane motions and deformations of microstructures. A new algorithm of sub-pixel step length correlation template matching is proposed to extract the in-plane displacement from vision images. Hariharan five-step phase-shift interferometry algorithm and unwrapping algorithms are adopted to measure the out-of-plane motions. It is demonstrated that the system can measure the motions of solder wetting in surface mount technology(SMT).

  14. Web Usage Statistics: Measurement Issues and Analytical Techniques.

    Science.gov (United States)

    Bertot, John Carlo; McClure, Charles R.; Moen, William E.; Rubin, Jeffrey

    1997-01-01

    One means of Web use evaluation is through analysis of server-generated log files. Various log file analysis techniques and issues are presented that are related to the interpretation of log file data. Study findings indicate a number of problems; recommendations and areas needing further research are outlined. (AEF)

  15. Free-flight measurement technique in the free-piston high-enthalpy shock tunnel.

    Science.gov (United States)

    Tanno, H; Komuro, T; Sato, K; Fujita, K; Laurence, S J

    2014-04-01

    A novel multi-component force-measurement technique has been developed and implemented at the impulse facility JAXA-HIEST, in which the test model is completely unrestrained during the test and thus experiences free-flight conditions for a period on the order of milliseconds. Advantages over conventional free-flight techniques include the complete absence of aerodynamic interference from a model support system and less variation in model position and attitude during the test itself. A miniature on-board data recorder, which was a key technology for this technique, was also developed in order to acquire and store the measured data. The technique was demonstrated in a HIEST wind-tunnel test campaign in which three-component aerodynamic force measurement was performed on a blunted cone of length 316 mm, total mass 19.75 kg, and moment of inertia 0.152 kgm(2). During the test campaign, axial force, normal forces, and pitching moment coefficients were obtained at angles of attack from 14° to 32° under two conditions: H0 = 4 MJ/kg, P0 = 14 MPa; and H0 = 16 MJ/kg, P0 = 16 MPa. For the first, low-enthalpy condition, the test flow was considered a perfect gas; measurements were thus directly compared with those obtained in a conventional blow-down wind tunnel (JAXA-HWT2) to evaluate the accuracy of the technique. The second test condition was a high-enthalpy condition in which 85% of the oxygen molecules were expected to be dissociated; high-temperature real-gas effects were therefore evaluated by comparison with results obtained in perfect-gas conditions. The precision of the present measurements was evaluated through an uncertainty analysis, which showed the aerodynamic coefficients in the HIEST low enthalpy test agreeing well with those of JAXA-HWT2. The pitching-moment coefficient, however, showed significant differences between low- and high-enthalpy tests. These differences are thought to result from high-temperature real-gas effects.

  16. Landscaping climate change: a mapping technique for understanding science and technology debates on the world wide web

    NARCIS (Netherlands)

    Rogers, R.; Marres, N.

    2000-01-01

    New World Wide Web (web) mapping techniques may inform and ultimately facilitate meaningful participation in current science and technology debates. The technique described here "landscapes" a debate by displaying key "webby" relationships between organizations. "Debate-scaping" plots two organizati

  17. Landscaping climate change: a mapping technique for understanding science and technology debates on the world wide web

    NARCIS (Netherlands)

    Rogers, R.; Marres, N.

    2000-01-01

    New World Wide Web (web) mapping techniques may inform and ultimately facilitate meaningful participation in current science and technology debates. The technique described here "landscapes" a debate by displaying key "webby" relationships between organizations. "Debate-scaping" plots two organizati

  18. Landscaping climate change: a mapping technique for understanding science and technology debates on the world wide web

    NARCIS (Netherlands)

    Rogers, R.; Marres, N.

    2000-01-01

    New World Wide Web (web) mapping techniques may inform and ultimately facilitate meaningful participation in current science and technology debates. The technique described here "landscapes" a debate by displaying key "webby" relationships between organizations. "Debate-scaping" plots two

  19. Evaluation of technological measures to cope with climate change

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, Hiroshi; Moriguchi, Yulchi [National Inst. for Environmental Studies, Onogawa Tsukuba (Japan)

    1993-12-31

    Because the global warming (climate change) is recognized as a highly probable phenomenon in the next century, the countermeasures to cope with this issue is really Important. International discussion Is progressing towards the conclusion of the treaty to stabilize global warming. Therefore, now is the time to take concrete action to reduce the emission to the greenhouse gases (GHG). To find the way to reduce the emission of the GHG, the procedure as next should be taken. (1) Systematic estimation of GHG emission (GHG analysis), (2) Identification of conventional and Innovative technologies, (3) Assessment of individual sectoral technologies, (4) Comprehensive evaluation of countermeasures as a whole. Both in the U.S.A. and Japan, this kind of research have been made independently. Among these processes, the standard methodologies should be established on the GHG analysis, the assessment of individual technologies and the comprehensive evaluation. From such a background, it is important to discuss the way to evaluate technological measures to cope with climate change between the specialist from the U.S.A. and Japan. And still required to search the possibility to establish a joint project between both countries.

  20. Technological Basis and Scientific Returns for Absolutely Accurate Measurements

    Science.gov (United States)

    Dykema, J. A.; Anderson, J.

    2011-12-01

    The 2006 NRC Decadal Survey fostered a new appreciation for societal objectives as a driving motivation for Earth science. Many high-priority societal objectives are dependent on predictions of weather and climate. These predictions are based on numerical models, which derive from approximate representations of well-founded physics and chemistry on space and timescales appropriate to global and regional prediction. These laws of chemistry and physics in turn have a well-defined quantitative relationship with physical measurement units, provided these measurement units are linked to international measurement standards that are the foundation of contemporary measurement science and standards for engineering and commerce. Without this linkage, measurements have an ambiguous relationship to scientific principles that introduces avoidable uncertainty in analyses, predictions, and improved understanding of the Earth system. Since the improvement of climate and weather prediction is fundamentally dependent on the improvement of the representation of physical processes, measurement systems that reduce the ambiguity between physical truth and observations represent an essential component of a national strategy for understanding and living with the Earth system. This paper examines the technological basis and potential science returns of sensors that make measurements that are quantitatively tied on-orbit to international measurement standards, and thus testable to systematic errors. This measurement strategy provides several distinct benefits. First, because of the quantitative relationship between these international measurement standards and fundamental physical constants, measurements of this type accurately capture the true physical and chemical behavior of the climate system and are not subject to adjustment due to excluded measurement physics or instrumental artifacts. In addition, such measurements can be reproduced by scientists anywhere in the world, at any time

  1. Characterization of small antennas for hearing aids by several measurement techniques

    DEFF Research Database (Denmark)

    Pivnenko, Sergey; Zhang, Jiaying; Khatun, Afroza;

    2010-01-01

    Characteristics of electrically small loop antennas were measured by different techniques and the results were compared in-between. The techniques employed were: a single-probe spherical near-field technique, a multi-probe spherical near-field technique, a reverberation chamber, and a Wheeler cap...

  2. Mitigation technologies and measures in energy sector of Kazakstan

    Energy Technology Data Exchange (ETDEWEB)

    Pilifosova, O.; Danchuk, D.; Temertekov, T. [and others

    1996-12-31

    An important commitment in the UN Framework Convention on Climate Change is to conduct mitigation analysis and to communicate climate change measures and policies. In major part reducing CO{sub 2} as well as the other greenhouse gas emissions in Kazakstan, can be a side-product of measures addressed to increasing energy efficiency. Since such measures are very important for the national economy, mitigation strategies in the energy sector of Kazakstan are directly connected with the general national strategy of the energy sector development. This paper outlines the main measures and technologies in energy sector of Kazakstan which can lead to GHG emissions reduction and presents the results of current mitigation assessment. The mitigation analysis is addressed to energy production sector. A baseline and six mitigation scenarios were developed to evaluate the most attractive mitigation options, focusing on specific technologies which have been already included in sustainable energy programs. According to the baseline projection, Kazakstan`s CO{sub 2} emissions will not exceed their 1990 level until 2005. The potential for CO{sub 2} emission reduction is estimated to be about 11 % of the base line emission level by the end of considered period (in 2020). The main mitigation options in the energy production sector in terms of mitigation potential and technical and economical feasibility include rehabilitation of thermal power plants aimed to increasing efficiency, use of nuclear energy and further expansion in the use of hydro energy based on small hydroelectric power plants.

  3. Integration of Machining and Measuring Processes Using On-Machine Measurement Technology

    Institute of Scientific and Technical Information of China (English)

    Myeong; Woo; Cho; Tae; Il; Seo; Dong; Sam; Park

    2002-01-01

    This paper presents an integration methodology for ma chining and measuring processes using OMM (On-Machine Measurement) technology b ased on CAD/CAM/CAI integration concept. OMM uses a CNC machining center as a me asuring station by changing the tools into measuring probes such as touch-type, laser and vision. Although the measurement accuracy is not good compared to tha t of the CMM (Coordinate Measuring Machine), there are distinctive advantages us ing OMM in real situation. In this paper, two topics a...

  4. A Technique for Measuring the Solubilities of Gases in Liquids

    Science.gov (United States)

    1990-12-01

    measured using a mercury manometer referenced to vacuum. To begin the experiment, a pure, dry gas is injected quickly into the system by opening valve...Tbath Vx - v - V 2 - V 3Apfinal Tm where Pb - ambient pressure (mmHg). The ambient pressure is measured using a mercury manometer and the ambient

  5. Children with smoking parents have a higher airway resistance measured by the interruption technique

    NARCIS (Netherlands)

    Kooi, EMW; Vrijlandt, Elianne J.L.E.; Boezen, HM; Duiverman, EJ

    2004-01-01

    Children exposed to environmental tobacco smoke, during or after pregnancy, are known to have decreased lung function. So far this has been measured using spirometry in schoolchildren and invasive techniques in newborns. The interruption technique (Rint) is a noninvasive technique to measure airway

  6. Novel Measurements and Techniques for Outlet Glacier Fjord Ice/Ocean Interactions

    Science.gov (United States)

    Behar, A.; Howat, I. M.; Holland, D. M.; Ahlstrom, A. P.; Larsen, S. H.

    2014-12-01

    Glacier fjord bathymetry and conditions indicate that they play fundamental roles for outlet glacier dynamics and thus knowledge of these parameters is extremely beneficial to upcoming models that predict changes. In particular, the bathymetry of a fjord gives important information about the exchange between fjord waters close to marine-terminating glaciers and the shelf and ocean. Currently, only sparse bathymetric data near the ice fronts are available for the majority of fjords in Greenland. The challenge in obtaining these measurements is that the fjord melange environment is a terrible one for mechanical gear, or ship or any other kind of access. There is hope however, and this work focuses on novel ways of obtaining this data using a multitude of upcoming technologies and techniques that are now being tested and planned. The span of the techniques described include but are not limited to: 1) manned helicopter-based live-reading instruments and deployable/retriavable sensor packages http://www.motionterra.com/fjord/ 2) remote or autonomous unmanned miniature boats (Depth/CTD), and 3) UAV's that either read live data or deploy small sensors that can telemeter their data (ice-flow trackers, image acquisition, etc.). A review of current results obtained at Jakobshavn and Upernavik Glaciers will be given as well as a description of the techniques and hardware used.

  7. Comparison global sensitivity analysis techniques and importance measures in probabilistic safety assessment

    Energy Technology Data Exchange (ETDEWEB)

    Borgonovo, E.; Apostalakis, G. E.; Tarantola, S.; Saltelli, A.

    2001-07-01

    Probabilistic Safety Assessment (PSA) computes the risk of complex technological systems. The core damage frequency (CDF) and the large early release frequency (LERF) are usually the risk metrics of interest in nuclear power plants (NPP). Epistemic uncertainty affects the use of PSA model results. In fact, because of the lack of knowledge in the parameters values, the risk metrics become uncertain and described by epistemic distributions (Apostokalis, 1995). In this paper, we discuss the use of Global Sensitivity Analysis (GSA) techniques for the determination of the parameters that contribute to the uncertainty in R and most. This information cannot be gained through the use of traditional importance measures (IMs), since: (1) IMs are defined for components and basic events and not for parameters, (2) IMs assume the parameters at their nominal values, and are therefore Local Methods. In Section 2 we discuss that, because of epistemic uncertainty, GSA must be performed through the PSA model parameters, and not at the basic event level. in Section 3 we present the definition of the PSA IMs and GSA techniques used in this work. In Section 4 we present the approach to compare PSA IMs results to GSA results, to understand whether uncertainty drivers are also important risk contributors. Results will be discussed for the application of these techniques and the proposed approach to the PSA large loss of coolant accident (LOCA) sequence of a research reactor. (Author) 7 refs.

  8. Adequate Measuring Technology and System of Fission Gas release Behavior from Voloxidation Process

    Energy Technology Data Exchange (ETDEWEB)

    Park, Geun Il; Park, J. J.; Jung, I. H.; Shin, J. M.; Yang, M. S.; Song, K. C

    2006-09-15

    Based on the published literature and an understanding of available hot cell technologies, more accurate measuring methods for each volatile fission product released from voloxidation process were reviewed and selected. The conceptual design of an apparatus for measuring volatile and/or semi-volatile fission products released from spent fuel was prepared. It was identified that on-line measurement techniques can be applied for gamma-emitting fission products, and off-line measurement such as chemical/or neutron activation analysis can applied for analyzing beta-emitting fission gases. Collection methods using appropriate material or solutions were selected to measure the release fraction of beta-emitting gaseous fission products at IMEF M6 hot cell. Especially, the on-line gamma-ray counting system for monitoring of 85Kr and the off-line measuring system of 14C was established. On-line measuring system for obtaining removal ratios of the semi-volatile fission products, mainly gamma-emitting fission products such as Cs, Ru etc., was also developed at IMEF M6 hot cell which was based on by measuring fuel inventory before and after the voloxidation test through gamma measuring technique. The development of this measurement system may enable basic information to be obtained to support design of the off-gas treatment system for the voloxidation process at INL, USA.

  9. Tools and Techniques for Measuring and Improving Grid Performance

    Science.gov (United States)

    Biswas, Rupak; Frumkin, M.; Smith, W.; VanderWijngaart, R.; Wong, P.; Biegel, Bryan (Technical Monitor)

    2001-01-01

    This viewgraph presentation provides information on NASA's geographically dispersed computing resources, and the various methods by which the disparate technologies are integrated within a nationwide computational grid. Many large-scale science and engineering projects are accomplished through the interaction of people, heterogeneous computing resources, information systems and instruments at different locations. The overall goal is to facilitate the routine interactions of these resources to reduce the time spent in design cycles, particularly for NASA's mission critical projects. The IPG (Information Power Grid) seeks to implement NASA's diverse computing resources in a fashion similar to the way in which electric power is made available.

  10. Ultrathin magnetic structures II measurement techniques and novel magnetic properties

    CERN Document Server

    Heinrich, Bretislav

    2006-01-01

    The ability to understand and control the unique properties of interfaces has created an entirely new field of magnetism, with profound impact in technology and serving as the basis for a revolution in electronics. Our understanding of the physics of magnetic nanostructures has also advanced significantly. This rapid development has generated a need for a comprehensive treatment that can serve as an introduction to the field for those entering it from diverse fields, but which will also serve as a timely overview for those already working in this area. The four-volume work Ultra-Thin Magnetic

  11. NASA ATP Force Measurement Technology Capability Strategic Plan

    Science.gov (United States)

    Rhew, Ray D.

    2008-01-01

    The Aeronautics Test Program (ATP) within the National Aeronautics and Space Administration (NASA) Aeronautics Research Mission Directorate (ARMD) initiated a strategic planning effort to re-vitalize the force measurement capability within NASA. The team responsible for developing the plan included members from three NASA Centers (Langley, Ames and Glenn) as well as members from the Air Force s Arnold Engineering and Development Center (AEDC). After visiting and discussing force measurement needs and current capabilities at each participating facility as well as selected force measurement companies, a strategic plan was developed to guide future NASA investments. This paper will provide the details of the strategic plan and include asset management, organization and technology research and development investment priorities as well as efforts to date.

  12. Correlation techniques and measurements of wave-height statistics

    Science.gov (United States)

    Guthart, H.; Taylor, W. C.; Graf, K. A.; Douglas, D. G.

    1972-01-01

    Statistical measurements of wave height fluctuations have been made in a wind wave tank. The power spectral density function of temporal wave height fluctuations evidenced second-harmonic components and an f to the minus 5th power law decay beyond the second harmonic. The observations of second harmonic effects agreed very well with a theoretical prediction. From the wave statistics, surface drift currents were inferred and compared to experimental measurements with satisfactory agreement. Measurements were made of the two dimensional correlation coefficient at 15 deg increments in angle with respect to the wind vector. An estimate of the two-dimensional spatial power spectral density function was also made.

  13. Measuring techniques for autogenous strain of cement paste

    DEFF Research Database (Denmark)

    Lura, Pietro; Jensen, Ole Mejlhede

    2006-01-01

    Volumetric measurement of autogenous strain is frequently performed by placing the fresh cement paste in a rubber membrane submerged in water. The volume change of the cement paste is measured by the amount of water displaced by the submerged sample. Volumetric and linear measurements of autogenous...... of the volumetric method. Water absorption is driven by a lowering of the water activity in the cement paste due to dissolved salts in the pore fluid and to self-desiccation. From the moment of casting, significant water uptake was registered in all experiments. This water uptake influenced the volumetric...... on the same cement pastes....

  14. Measuring techniques for autogenous strain of cement paste

    DEFF Research Database (Denmark)

    Lura, Pietro; Jensen, Ole Mejlhede

    2007-01-01

    Volumetric measurement of autogenous strain is frequently performed by placing the fresh cement paste in a rubber membrane submerged in water. The volume change of the cement paste is measured by the amount of water displaced by the submerged sample. Volumetric and linear measurements of autogenous...... of the volumetric method. Water absorption is driven by a lowering of the water activity in the cement paste due to dissolved salts in the pore fluid and to self-desiccation. From the moment of casting, significant water uptake was registered in all experiments. This water uptake influenced the volumetric...... on the same cement pastes....

  15. Measurements of dimensional accuracy using linear and scanning profile techniques.

    Science.gov (United States)

    Harrison, A; Huggett, R; Zissis, A

    1992-01-01

    Various measurement methods have been described for the determination of dimensional accuracy and stability of denture base materials. This investigation introduces a computerised coordinate measuring machine (CCMM) and compares it with two methods routinely used for assessment of the accuracy of fit of denture base materials. The results demonstrate that the three methods (digital calipers, optical comparator, and CCMM) are acceptable for linear measurement. The CCMM was also used in its scanning mode to define and to quantify the contour changes of the resin bases. The advantages of the CCMM become apparent when two-dimensional changes require assessment.

  16. Technology and education: First approach for measuring temperature with Arduino

    Science.gov (United States)

    Carrillo, Alejandro

    2017-04-01

    This poster session presents some ideas and approaches to understand concepts of thermal equilibrium, temperature and heat in order to bulid a man-nature relationship in a harmonious and responsible manner, emphasizing the interaction between science and technology, without neglecting the relationship of the environment and society, an approach to sustainability. It is proposed the development of practices that involve the use of modern technology, of easy access and low cost to measure temperature. We believe that the Arduino microcontroller and some temperature sensors can open the doors of innovation to carry out such practices. In this work we present some results of simple practices presented to a population of students between the ages of 16 and 17 years old. The practices in this proposal are: Zero law of thermodynamics and the concept of temperature, calibration of thermometers and measurement of temperature for heating and cooling of three different substances under the same physical conditions. Finally the student is asked to make an application that involves measuring of temperature and other physical parameters. Some suggestions are: to determine the temperature at which we take some food, measure the temperature difference at different rooms of a house, housing constructions that favour optimal condition, measure the temperature of different regions, measure of temperature trough different colour filters, solar activity and UV, propose applications to understand current problems such as global warming, etc. It is concluded that the Arduino practices and electrical sensors increase the cultural horizon of the students while awaking their interest to understand their operation, basic physics and its application from a modern perspective.

  17. Sustainable Phosphorus Measures: Strategies and Technologies for Achieving Phosphorus Security

    Directory of Open Access Journals (Sweden)

    Stuart White

    2013-01-01

    Full Text Available Phosphorus underpins the world’s food systems by ensuring soil fertility, maximising crop yields, supporting farmer livelihoods and ultimately food security. Yet increasing concerns around long-term availability and accessibility of the world’s main source of phosphorus—phosphate rock, means there is a need to investigate sustainable measures to buffer the world’s food systems against the long and short-term impacts of global phosphorus scarcity. While the timeline of phosphorus scarcity is contested, there is consensus that more efficient use and recycling of phosphorus is required. While the agricultural sector will be crucial in achieving this, sustainable phosphorus measures in sectors upstream and downstream of agriculture from mine to fork will also need to be addressed. This paper presents a comprehensive classification of all potential phosphorus supply- and demand-side measures to meet long-term phosphorus needs for food production. Examples range from increasing efficiency in the agricultural and mining sector, to technologies for recovering phosphorus from urine and food waste. Such measures are often undertaken in isolation from one another rather than linked in an integrated strategy. This integrated approach will enable scientists and policy-makers to take a systematic approach when identifying potential sustainable phosphorus measures. If a systematic approach is not taken, there is a risk of inappropriate investment in research and implementation of technologies and that will not ultimately ensure sufficient access to phosphorus to produce food in the future. The paper concludes by introducing a framework to assess and compare sustainable phosphorus measures and to determine the least cost options in a given context.

  18. Apt strain measurement technique for impulsive loading applications

    Science.gov (United States)

    Ranjan Nanda, Soumya; Kulkarni, Vinayak; Sahoo, Niranjan

    2017-03-01

    The necessity of precise measurement of strain time history for impulsive loading applications has been addressed in the present investigation. Finite element modeling is initially carried out for a hemispherical test model and stress bar assembly to arrive at an appropriate location for strain measurement. In dynamic calibration experiments, strain measurements are performed using two wire and three wire quarter bride arrangements along with half bridge circuit. Usefulness of these arrangements has been verified by analyzing strain signals in time and frequency domains. Comparison of recovered force time histories proved that the half bridge circuit is the most suitable for such applications. Actual shock tube testing of the instrumented hemispherical test model confirmed the applicability of half bridge circuit for short duration strain measurements.

  19. Advances in bioanalytical techniques to measure steroid hormones in serum.

    Science.gov (United States)

    French, Deborah

    2016-06-01

    Steroid hormones are measured clinically to determine if a patient has a pathological process occurring in the adrenal gland, or other hormone responsive organs. They are very similar in structure making them analytically challenging to measure. Additionally, these hormones have vast concentration differences in human serum adding to the measurement complexity. GC-MS was the gold standard methodology used to measure steroid hormones clinically, followed by radioimmunoassay, but that was replaced by immunoassay due to ease of use. LC-MS/MS has now become a popular alternative owing to simplified sample preparation than for GC-MS and increased specificity and sensitivity over immunoassay. This review will discuss these methodologies and some new developments that could simplify and improve steroid hormone analysis in serum.

  20. Impression technique for a complete-arch prosthesis with multiple implants using additive manufacturing technologies.

    Science.gov (United States)

    Revilla-León, Marta; Sánchez-Rubio, José Luis; Oteo-Calatayud, Jesús; Özcan, Mutlu

    2017-06-01

    This article describes an impression technique for a complete-arch prosthesis supported by multiple implants where additive manufacturing technologies were used to fabricate a splinting framework and a custom tray. The technique presented uses a shim method to control the homogenous splinting acrylic resin and impression material during the procedure, thereby reducing laboratory and chairside time and the number of impression copings and laboratory analogs needed. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  1. Auroral ionospheric and thermospheric measurements using the incoherent scatter technique

    Energy Technology Data Exchange (ETDEWEB)

    Kofman, W. (CEPHAG, St. Martin (France))

    1992-11-01

    The incoherent scatter technique has been applied since 1965 to study the ionosphere and thermosphere in different regions of the Earth. The analysis of the received signal gives access to several ionospheric parameters as a function of height: electron density, electron and ion temperatures and ion velocity. The derivation of these parameters is usually a complicated mathematical procedure that requires a non-linear regression program. A lot of research has been done in the ionospheric and atmospheric science using this technique. In this paper we describe how one derives the ion-neutral collision frequency and the ion composition parameters. It is usually difficult to retrieve these parameters with the incoherent scatter technique; as a result, in the standard data analysis procedure, an ionospheric model is used instead. However the numerical values chosen in the model have an influence on the other derived parameters. For instance the choice of a wrong ion composition leads to erroneous plasma temperatures. It is therefore important to assess by how much the standard procedure deviates from reality. For this reason we compare the ion composition and collision frequency retrieved from a sophisticated analysis scheme with the values that are derived from models under similar geophysical conditions. It is also possible to derive from the observed ionospheric parameters the neutral concentrations, temperatures and winds, by using the energy and momentum equations for the ions and the neutrals. In this paper the different methods and the corresponding assumptions involved in the data analysis are discussed. We describe the influence of the frictional heating, of the vertical neutral wind and of the ionospheric perturbations on the derivation of the neutral atmospheric parameters. Our discussion of the processes involved are drawn from results obtained by Chatanika, Sondrestrom and EISCAT radars.

  2. Continuous measurement of cardiac output using stochastic system identification techniques.

    Science.gov (United States)

    Yelderman, Mark

    2004-01-01

    Indicator dilutions techniques offer the most reliable methods of determining clinical cardiac output because of the elastic nature of the cardiac vessels. A catheter-mounted beating filament affords a simple means of supplying "heat" indicator, but is power and temperature limited because of possible patient injury. A stochastic signal processing method using pseudorandom binary infusion of heat offers a process of enhancing the signal to noise sufficiently to facilitate a computation of cardiac output over a reasonable time period (5 min) with a clinically acceptable error.

  3. A reevaluation of the interrupter technique for airway resistance measurement

    Science.gov (United States)

    Jackson, A. C.; Milhorn, H. T., Jr.; Norman, J. R.

    1974-01-01

    An attempt was made to obtain a better insight into the actual transient response of airway opening pressure (Pao) following rapid occlusion. With this knowledge it was hoped to be able to clarify the reason for the overestimations found by other investigators, and possibly to obtain a more accurate method of estimating alveolar pressure just prior to interruption. This would result in an improved method for estimating airway resistance. Use of an extrapolation method was found to provide an improved correlation between resistances determined by the interruptor technique and those found by the plethysmograph in normal subjects.

  4. A Review of Techniques to Measure Protein Sorption to Soft Contact Lenses.

    Science.gov (United States)

    Hall, Brad; Forrest, James A; Jones, Lyndon

    2017-09-01

    To compare and critically evaluate a variety of techniques to measure the quantity and biological activity of protein sorption to contact lenses over short time periods. A literature review was undertaken investigating the major techniques to measure protein sorption to soft contact lens materials, with specific reference to measuring protein directly on lenses using in situ, ex situ, protein structural, and biological activity techniques. The use of in situ techniques to measure protein quantity provides excellent sensitivity, but many are not directly applicable to contact lenses. Many ex situ techniques struggle to measure all sorbed proteins, and these measurements can have significant signal interference from the lens materials themselves. Techniques measuring the secondary and tertiary structures of sorbed proteins have exhibited only limited success. There are a wide variety of techniques to measure both the amount of protein and the biological activity of protein sorbed to soft contact lens materials. To measure the mass of protein sorbed to soft contact lenses (not just thin films) over short time periods, the method of choice should be I radiolabeling. This technique is sensitive enough to measure small amounts of deposited protein, provided steps are taken to limit and measure any interaction of the iodine tracer with the materials. To measure the protein activity over short time periods, the method of choice should be to measure the biological function of sorbed proteins. This may require new methods or adaptations of existing ones.

  5. OVERVIEW OF WORK PIECE TEMPERATURE MEASUREMENT TECHNIQUES FOR MACHINING OF Ti6Al4V#

    Directory of Open Access Journals (Sweden)

    P.J.T. Conradie

    2012-01-01

    Full Text Available

    ENGLISH ABSTRACT: Ti6Al4V is one of the most widely used titanium alloys in aerospace applications, but its machining remains a challenge. Comprehensive research has been done in the past, mainly investigating tool failure of various materials. Less research has been done to investigate the thermal effect of machining on work piece quality, including fatigue performance. Temperature measurement is considered to be a key enabling technology. This study presents an overview of current temperature measurement techniques for machined and tool surfaces. Two categories of methods were investigated: slower contact, and faster optical methods. Optical fibre two colour pyrometry experiments are reported that demonstrate the technique’s adequate response time. The infrared camera temperature measurement experiments synchronised temperature measurement with visual observation, aimed at mechanism analysis. The results corresponded with the literature.

    AFRIKAANSE OPSOMMING: Ti6Al4V is een van die mees gewilde lugvaart allooie, maar sy masjinering is ’n uitdaging. Bestaande navorsing dek beitelslytasie omvattend. Die termiese effek van masjinering op werkstuk integriteit, insluitend vermoeiingleeftyd, het egter veel minder dekking geniet. Temperatuurmeting wat in hierdie studie ondersoek word, word as ’n sleuteltegnologie beskou. Twee kategorië metodes is ondersoek, nl stadige kontakmetodes en optiese metodes met vinnige respons, wat die meting van oorgangsverskynsels moontlik maak. Eksperimentele werk wat beide optiese vesel tweekleurpirometrie en termiese kamera tegnieke insluit bewys die tegnieke as geskik vir die benodigde navorsing.

  6. Measurement of particle size based on digital imaging technique

    Institute of Scientific and Technical Information of China (English)

    CHEN Hong; TANG Hong-wu; LIU Yun; WANG Hao; LIU Gui-ping

    2013-01-01

    To improve the analysis methods for the measurement of the sediment particle sizes with a wide distribution and of irregular shapes,a sediment particle image measurement,an analysis system,and an extraction algorithm of the optimal threshold based on the gray histogram peak values are proposed.Recording the pixels of the sediment particles by labeling them,the algorithm can effectively separate the sediment particle images from the background images using the equivalent pixel circles with the same diameters to represent the sediment particles.Compared with the laser analyzer for the case of blue plastic sands,the measurement results of the system are shown to be reasonably similar.The errors are mainly due to the small size of the particles and the limitation of the apparatus.The measurement accuracy can be improved by increasing the Charge-Coupled Devices (CCD) camera resolution.The analysis method of the sediment particle images can provide a technical support for the rapid measurement of the sediment particle size and its distribution.

  7. Comparison of transepithelial resistance measurement techniques: Chopsticks vs. Endohm.

    Science.gov (United States)

    Sheller, Rebecca A; Cuevas, Maria E; Todd, Maria C

    2017-01-01

    TER measurements across confluent cellular monolayers provide a useful indication of TJ strength between epithelial and endothelial cells in culture. Having a reliable and accurate method of measuring cell-to-cell adhesion is critical to studies in pathophysiology and cancer metastasis. However, the use of different technical approaches to measure TER has reportedly yielded inconsistent measurements within the same cell lines. In the current study, we compared the peak TER values for the MDCK (canine kidney) and MCF-7 (human breast cancer) epithelial cell lines using two common approaches (Chopstick and Endohm) and two types of polymer inserts (PC and PET). Both cell lines demonstrated a statistically significant difference in the peak TERs obtained using the two different approaches. Further, the MDCK (but not the MCF-7) cells demonstrated a statistically significant difference between the peak TERs when using the same approach but different inserts. Our study indicates the importance of using a single approach when seeking to measure and compare the TER values of cultured cell lines.

  8. Working Group 5: Measurements technology and active experiments

    Science.gov (United States)

    Whipple, E.; Barfield, J. N.; Faelthammar, C.-G.; Feynman, J.; Quinn, J. N.; Roberts, W.; Stone, N.; Taylor, W. L.

    1986-01-01

    Technology issues identified by working groups 5 are listed. (1) New instruments are needed to upgrade the ability to measure plasma properties in space. (2) Facilities should be developed for conducting a broad range of plasma experiments in space. (3) The ability to predict plasma weather within magnetospheres should be improved and a capability to modify plasma weather developed. (4) Methods of control of plasma spacecraft and spacecraft plasma interference should be upgraded. (5) The space station laboratory facilities should be designed with attention to problems of flexibility to allow for future growth. These issues are discussed.

  9. Instrument maintenance of ultrasonic influences parameters measurement in technological processes

    Directory of Open Access Journals (Sweden)

    Tomal V. S.

    2008-04-01

    Full Text Available The contact and non-contact vibration meters for intermittent and continuous control of the vibration amplitude in the ultrasonic technological equipment have been developed. And in order to estimate the cavitation intensity in liquids the authors have developed cavitation activity indicators and cavitation sensitivity meters, allowing to measure the magnitude of the signal level in the range of maximum spectral density of cavitation noise. The developed instruments allow to improve the quality of products, reduce the defect rate and power consumption of equipment by maintaining optimum conditions of the process.

  10. A Cost Estimation Analysis of U.S. Navy Ship Fuel-Savings Techniques and Technologies

    Science.gov (United States)

    2009-09-01

    coastal waters during the present conflict in Iraq have experienced excessive filter usage rates and premature RO membrane failures. New... microfiltration (MF) technology can provide a superior level of filtration in most waters and can be renewed by backflushing techniques developed under an...ONR program. MF can facilitate operation in coastal and littoral waters and will also allow operating the RO plant at higher membrane recoveries

  11. Application of New Techniques, Materials and Technologies in West-East Gas Transportation Pipeline Project

    Institute of Scientific and Technical Information of China (English)

    DongXu

    2004-01-01

    With the application of new techniques, materials and technologies in West-East Gas Transportation Pipeline (WEGTP) project, the design concept of domestic pipeline industrial construction has been updated, speeding up the development and improvement of the strength as a whole in aspects of smelting industry, pipe fabrication, pipeline construction and equipment manufacture, making China's pipeline industry catch up with the trend of development of the world advanced level.

  12. The formation of students’ engineering thinking as a way to create new techniques, technologies, materials

    Science.gov (United States)

    Gilmanshin, Iskander; Gilmanshina, Suriya

    2016-06-01

    Engineering thinking is regarded as the quality of the person, which is stimulating the human need for the creation of new techniques, technologies and materials. Applications in the study of competence approach allows us to consider a professional thinking as one of the core competencies required for successful engineer innovations in mechanical engineering. The author's definition of professional engineering thinking is presented. The ways of its formation at students of technical fields enrolled in university courses are illustrated

  13. Method of pectus excavatum measurement based on structured light technique

    Science.gov (United States)

    Glinkowski, Wojciech; Sitnik, Robert; Witkowski, Marcin; Kocoń, Hanna; Bolewicki, Pawel; Górecki, Andrzej

    2009-07-01

    We present an automatic method for assessment of pectus excavatum severity based on an optical 3-D markerless shape measurement. A four-directional measurement system based on a structured light projection method is built to capture the shape of the body surface of the patients. The system setup is described and typical measurement parameters are given. The automated data analysis path is explained. Their main steps are: normalization of trunk model orientation, cutting the model into slices, analysis of each slice shape, selecting the proper slice for the assessment of pectus excavatum of the patient, and calculating its shape parameter. We develop a new shape parameter (I3ds) that shows high correlation with the computed tomography (CT) Haller index widely used for assessment of pectus excavatum. Clinical results and the evaluation of developed indexes are presented.

  14. A digital coincidence measurement system using FPGA techniques

    Energy Technology Data Exchange (ETDEWEB)

    Zhu Fengming; Hsieh, S.C.; Yen, W.W. [Department of Engineering and System Science, National Tsing Hua University, Hsinchu, 30043, Taiwan (China); Chou, H.P., E-mail: hpc@ess.nthu.edu.tw [Department of Engineering and System Science, National Tsing Hua University, Hsinchu, 30043, Taiwan (China)

    2011-10-01

    A field programmable gate array (FPGA) based digital coincidence system has been developed to use with NaI scintillators for field applications. The analog output signal from the photomultiplier anode is directly transferred into digital signals by pulse height for pulse width conversion. The digital signal contains the energy and timing information of the radiation events. The pulse width is then measured by a vernier type of time-to-digital converter (TDC). The timing information of radiation events is recorded and analyzed by a coincidence unit. Both the TDC unit and the coincidence unit are implemented using a commercial available FPGA board. The measured data is then sent to a personal computer for spectrum display. Efficiency as well as energy calibration has been performed. The system showed a timing resolution about 13 ns and an energy resolution of 12% for 0.511 MeV annihilation gammas; it also successfully demonstrated the background rejection ability through coincidence measurement.

  15. Method of pectus excavatum measurement based on structured light technique.

    Science.gov (United States)

    Glinkowski, Wojciech; Sitnik, Robert; Witkowski, Marcin; Kocoń, Hanna; Bolewicki, Pawel; Górecki, Andrzej

    2009-01-01

    We present an automatic method for assessment of pectus excavatum severity based on an optical 3-D markerless shape measurement. A four-directional measurement system based on a structured light projection method is built to capture the shape of the body surface of the patients. The system setup is described and typical measurement parameters are given. The automated data analysis path is explained. Their main steps are: normalization of trunk model orientation, cutting the model into slices, analysis of each slice shape, selecting the proper slice for the assessment of pectus excavatum of the patient, and calculating its shape parameter. We develop a new shape parameter (I(3ds)) that shows high correlation with the computed tomography (CT) Haller index widely used for assessment of pectus excavatum. Clinical results and the evaluation of developed indexes are presented.

  16. Comparative technique in measurements of Ge detectors effective volumes

    Science.gov (United States)

    Demidova, E. V.; Kirpichnikov, I. V.; Vasenko, A. A.

    1999-01-01

    A simple and quick procedure was proposed for measurements of large coaxial Ge detectors effective volumes. It included a comparison of background spectra collected with several detectors without any shielding in an underground laboratory. Such measurements were performed in Homestake (USA) and Canfranc (Spain) laboratories with several 1 kg and 2 kg detectors. Monte-Carlo calculations confirmed that ratios of numbers of events in continua of the spectra should be either equal or very close to the ratios of the detectors effective volumes.

  17. Impedance technique for measuring dielectrophoretic collection of microbiological particles

    CERN Document Server

    Allsopp, D W E; Brown, A P; Betts, W B

    1999-01-01

    Measurement of the impedance change resulting from the collection of microbiological particles at coplanar electrodes is shown to be an effective and potentially quantitative method of detecting dielectrophoresis. Strong correlations between the frequency-dependent dielectrophoretic collection characteristics measured by impedance change and those observed using an established counting method based on image analysis have been obtained for Escherichia coli. In addition it is shown that the new electrical method can be used to sense dielectrophoretic collection of 19 nm diameter latex beads, particles too small to be resolved by conventional optical detection systems. (author)

  18. Calibration Techniques for Accurate Measurements by Underwater Camera Systems

    Directory of Open Access Journals (Sweden)

    Mark Shortis

    2015-12-01

    Full Text Available Calibration of a camera system is essential to ensure that image measurements result in accurate estimates of locations and dimensions within the object space. In the underwater environment, the calibration must implicitly or explicitly model and compensate for the refractive effects of waterproof housings and the water medium. This paper reviews the different approaches to the calibration of underwater camera systems in theoretical and practical terms. The accuracy, reliability, validation and stability of underwater camera system calibration are also discussed. Samples of results from published reports are provided to demonstrate the range of possible accuracies for the measurements produced by underwater camera systems.

  19. Calibration Techniques for Accurate Measurements by Underwater Camera Systems.

    Science.gov (United States)

    Shortis, Mark

    2015-12-07

    Calibration of a camera system is essential to ensure that image measurements result in accurate estimates of locations and dimensions within the object space. In the underwater environment, the calibration must implicitly or explicitly model and compensate for the refractive effects of waterproof housings and the water medium. This paper reviews the different approaches to the calibration of underwater camera systems in theoretical and practical terms. The accuracy, reliability, validation and stability of underwater camera system calibration are also discussed. Samples of results from published reports are provided to demonstrate the range of possible accuracies for the measurements produced by underwater camera systems.

  20. Usage and applications of Semantic Web techniques and technologies to support chemistry research.

    Science.gov (United States)

    Borkum, Mark I; Frey, Jeremy G

    2014-01-01

    The drug discovery process is now highly dependent on the management, curation and integration of large amounts of potentially useful data. Semantics are necessary in order to interpret the information and derive knowledge. Advances in recent years have mitigated concerns that the lack of robust, usable tools has inhibited the adoption of methodologies based on semantics. THIS PAPER PRESENTS THREE EXAMPLES OF HOW SEMANTIC WEB TECHNIQUES AND TECHNOLOGIES CAN BE USED IN ORDER TO SUPPORT CHEMISTRY RESEARCH: a controlled vocabulary for quantities, units and symbols in physical chemistry; a controlled vocabulary for the classification and labelling of chemical substances and mixtures; and, a database of chemical identifiers. This paper also presents a Web-based service that uses the datasets in order to assist with the completion of risk assessment forms, along with a discussion of the legal implications and value-proposition for the use of such a service. We have introduced the Semantic Web concepts, technologies, and methodologies that can be used to support chemistry research, and have demonstrated the application of those techniques in three areas very relevant to modern chemistry research, generating three new datasets that we offer as exemplars of an extensible portfolio of advanced data integration facilities. We have thereby established the importance of Semantic Web techniques and technologies for meeting Wild's fourth "grand challenge".

  1. Probe technologies for clean sampling and measurement of subglacial lakes.

    Science.gov (United States)

    Mowlem, Matt; Saw, Kevin; Brown, Robin; Waugh, Edward; Cardwell, Christopher L; Wyatt, James; Magiopoulos, Iordanis; Keen, Peter; Campbell, Jon; Rundle, Nicholas; Gkritzalis-Papadopoulos, Athanasios

    2016-01-28

    It is 4 years since the subglacial lake community published its plans for accessing, sampling, measuring and studying the pristine, and hitherto enigmatic and very different, Antarctic subglacial lakes, Vostok, Whillans and Ellsworth. This paper summarizes the contrasting probe technologies designed for each of these subglacial environments and briefly updates how these designs changed or were used differently when compared to previously published plans. A detailed update on the final engineering design and technical aspects of the probe for Subglacial Lake Ellsworth is presented. This probe is designed for clean access, is negatively buoyant (350 kg), 5.2 m long, 200 mm in diameter, approximately cylindrical and consists of five major units: (i) an upper power and communications unit attached to an optical and electrical conducting tether, (ii)-(iv) three water and particle samplers, and (v) a sensors, imaging and instrumentation pack tipped with a miniature sediment corer. To date, only in Subglacial Lake Whillans have instruments been successfully deployed. Probe technologies for Subglacial Lake Vostok (2014/15) and Lake Ellsworth (2012/13) were not deployed for technical reasons, in the case of Lake Ellsworth because hot-water drilling was unable to access the lake during the field season window. Lessons learned and opportunities for probe technologies in future subglacial access missions are discussed.

  2. A new technique for measurements of the urethra pressure profile.

    Science.gov (United States)

    Asmussen, M; Ulmsten, U

    1976-01-01

    A new standardized technique for continuous recording of the urethral pressure profile simultaneously with intravesical pressure has been developed. The pressures were recorded using two micr-transducers enclosed in a thin Dacron catheter. The catheter moved with a constant speed through the urethra with the aid of a specially designed instrument. This instrument is described. Twenty-five healthy women were examined. The patients were divided into two groups: (A) 10 postmenopausal women, and (B) 15 fertile women. The results of the recordings showed that the functional length and the absolute length of the urethra could be reproduced with an error of less than 1 mm. The maximal pressure amplitude was significantly less in group A.

  3. Technique for measuring speed and visual motion sensitivity in lizards

    Directory of Open Access Journals (Sweden)

    Darren Burke

    2008-01-01

    Full Text Available Testing sensory characteristics on herpetological species has been difficult due to a range of properties related to physiology, responsiveness, performance ability, and the type of reinforcer used. Using the Jacky lizard as a model, we outline a successfully established procedure in which to test the visual sensitivity to motion characteristics. We incorporated modifications to traditional operant paradigms by using three video playback systems to deliver random-dot kinematogram motion stimuli coupled with salient computer-animated secondary reinforcers representative of biologically important appetitive stimuli. This procedure has the capacity to test other visual aspects in lizards as well as other nonhuman species using video playback and computer-animation techniques as experimental tools.

  4. MEASURING THE LEANNESS OF SUPPLIERS USING PRINCIPAL COMPONENT ANALYSIS TECHNIQUE

    Directory of Open Access Journals (Sweden)

    Y. Zare Mehrjerdi

    2012-01-01

    Full Text Available

    ENGLISH ABSTRACT: A technique that helps management to reduce costs and improve quality is ‘lean supply chain management’, which focuses on the elimination of all wastes in every stage of the supply chain and is derived from ‘agile production’. This research aims to assess and rank the suppliers in an auto industry, based upon the concept of ‘production leanness’. The focus of this research is on the suppliers of a company called Touse-Omron Naein. We have examined the literature about leanness, and classified its criteria into ten dimensions and 76 factors. A questionnaire was used to collect the data, and the suppliers were ranked using the principal component analysis (PCA technique.

    AFRIKAANSE OPSOMMING: Lenige voorsieningsbestuur (“lean supply chain management” is ’n tegniek wat bestuur in staat stel om koste te verminder en gehalte te verbeter. Dit fokus op die vermindering van vermorsing op elke stadium van die voorsieningsketting en word afgelei van ratse vervaardiging (“agile production”. Hierdie navorsing poog om leweransiers in ’n motorbedryf te beoordeel aan die hand van die konsep van vervaardigingslenigheid (“production leanness”. Die navorsing fokus op leweransiers van ’n maatskappy genaamd Touse-Omron Naein. ’n Literatuurstudie aangaande lenigheid het gelei tot die klassifikasie van kriteria in tien dimensies en 76 faktore. ’n Vraelys is gebruik om die data te versamel en die leweransiers is in rangvolgorde geplaas aan die hand van die PCA-tegniek.

  5. Measuring the Readability of Elementary Algebra Using the Cloze Technique.

    Science.gov (United States)

    Kulm, Gerald

    The relationship to readability of ten variables characterizing structural properties of mathematical prose was investigated in elementary algebra textbooks. Readability was measured by algebra student's responses to two forms of cloze tests. Linear and currilinear correlations were calculated between each structural variable and the cloze test.…

  6. Measuring Student Growth: Techniques and Procedures for Occupational Education.

    Science.gov (United States)

    Erickson, Richard C.; Wentling, Tim L.

    Designed for current and future occupational instructors, counselors, and administrators, the comprehensive measurement text is directed toward all subject areas in occupational education--industrial, business/distributive, home economics, agriculture, health occupations, and personal/public services. It offers necessary guidelines to select,…

  7. An MSc Course Module: Wind Turbine Measurement Techniques

    DEFF Research Database (Denmark)

    Hansen, Kurt Schaldemose; Pedersen, Knud Ole Helgesen

    2005-01-01

    The 2-year MSc in Wind power engineering at the Technical University of Denmark comprises modules from core engineering teaching and from other modules specifically designed to the MSc. This Note outlines the content of such a specific module on the subject of wind turbine measurement. The lectures...

  8. Corruption in Higher Education: Conceptual Approaches and Measurement Techniques

    Science.gov (United States)

    Osipian, Ararat L.

    2007-01-01

    Corruption is a complex and multifaceted phenomenon. Forms of corruption are multiple. Measuring corruption is necessary not only for getting ideas about the scale and scope of the problem, but for making simple comparisons between the countries and conducting comparative analysis of corruption. While the total impact of corruption is indeed…

  9. A simple technique for a.c. conductivity measurements

    Indian Academy of Sciences (India)

    R Padma Suvarna; K Raghavendra Rao; K Subbarangaiah

    2002-12-01

    An inexpensive, indigenous and a simple electronic instrument based on voltage follower, current–to–voltage converter, zero crossing detector and a phase detector has been developed for measurement of a.c. conductivity. Real and imaginary parts of complex impedance are determined for a given sample as a function of frequency and the given sample is represented by a pure electronic model.

  10. A numerical technique to design blast noise mitigation measures

    NARCIS (Netherlands)

    Berg, F. van den; Eerden, F.J.M. van der

    2007-01-01

    Large weapons, such as armor, artillery or demolitions, create a high-energy blast wave. It has a low frequency content, typically between 15 and 125 Hz, and can propagate over large distances. As a result it is a relative important cause for annoyance. Mitigation measures need to be close to the so

  11. A numerical technique to design blast noise mitigation measures

    NARCIS (Netherlands)

    Berg, F. van den; Eerden, F.J.M. van der

    2007-01-01

    Large weapons, such as armor, artillery or demolitions, create a high-energy blast wave. It has a low frequency content, typically between 15 and 125 Hz, and can propagate over large distances. As a result it is a relative important cause for annoyance. Mitigation measures need to be close to the

  12. INSTRUMENTATION DEVELOPMENT, MEASUREMENT AND PERFORMANCE EVALUATION OF ENVIRONMENTAL TECHNOLOGIES

    Energy Technology Data Exchange (ETDEWEB)

    Unknown

    2001-12-31

    Many DOE applications would significantly benefit from the availability of robust and convenient instrumentation for trace-level actinide monitoring and analysis. This project focuses on developing new instrumentation for on-line or at-line monitoring for actinides with isotopic analysis capability. In addition, analytical protocols for a novel concentration method for actinides are being investigated. These efforts focus on demonstrating these techniques using uranium. In addition to its value in the analytical laboratory, the combination of a simple concentration technique with a robust isotopic monitor could provide a powerful method for addressing a number of outstanding DOE needs. Potential applications include monitors for waste water and sewage treatment systems influent and effluent, and the ability to determine the isotopic content of transuranic species in low-activity waste fractions for waste classification and product acceptance. For example, the need for improved monitoring for uranium, plutonium, and americium in treatment plant influent is clearly identified in need RF-ER11. With some additional sample pretreatment, such technology could also impact materials characterization needs by providing on-site isotopic analyses in a system that is smaller and significantly less complex than inductively coupled plasma mass spectrometry (ICP-MS).

  13. The laser measurement technology of combustion flow field

    Science.gov (United States)

    Wang, Mingdong; Wang, Guangyu; Qu, Dongsheng

    2014-07-01

    The parameters of combustion flow field such as temperature, velocity, pressure and mole-fraction are of significant value in engineering application. The laser spectroscopy technology which has the non-contact and non- interference properties has become the most important method and it has more advantages than conventionally contacting measurement. Planar laser induced fluorescence (PLIF/LIF) is provided with high sensibility and resolution. Filtered Rayleigh scattering (FRS) is a good measurement method for complex flow field .Tunable diode laser absorption spectroscopy (TDLAS) is prosperity on development and application. This article introduced the theoretical foundation, technical principle, system structure, merits and shortages. It is helpful for researchers to know about the latest development tendency and do the related research.

  14. Tools and techniques to measure mitophagy using fluorescence microscopy.

    Science.gov (United States)

    Dolman, Nick J; Chambers, Kevin M; Mandavilli, Bhaskar; Batchelor, Robert H; Janes, Michael S

    2013-11-01

    Mitophagy is a specialized form of autophagy that removes damaged mitochondria, thereby maintaining efficient cellular metabolism and reducing cellular stress caused by aberrant oxidative bursts. Deficits in mitophagy underlie several diseases, and a substantial body of research has elucidated key steps in the pathways that lead to and execute autophagic clearance of mitochondria. Many of these studies employ fluorescence microscopy to visualize mitochondrial morphology, mass, and functional state. Studies in this area also examine colocalization/recruitment of accessory factors, components of the autophagic machinery and signaling molecules to mitochondria. In this review, we provide a brief summary of the current understanding about the processes involved in mitophagy followed by a discussion of probes commonly employed and important considerations of the methodologies to study and analyze mitophagy using fluorescence microscopy. Representative data, where appropriate, are provided to highlight the use of key probes to monitor mitophagy. The review will conclude with a consideration of new possibilities for mitophagy research and a discussion of recently developed technologies for this emerging area of cell biology.

  15. A Free-Space Measurement Technique of Terahertz Dielectric Properties

    Science.gov (United States)

    Zhang, Xiansheng; Chang, Tianying; Cui, Hong-Liang; Sun, Zhonglin; Yang, Chuanfa; Yang, Xiuwei; Liu, Lingyu; Fan, Wei

    2017-03-01

    The free-space method for material dielectric characterization in the microwave band is extended to terahertz frequencies. By analyzing the advantages and disadvantages of the relative permittivity of the transmission/reflection method for non-magnetic materials, a fast calculation method using a transmission-only method is proposed. Based on the convergence analysis of the algorithm, a method to estimate the initial value is also proposed. Finally, through measurements of the permittivity of high-density polyethylene, polystyrene, polypropylene, and polymethyl methacrylate in the 325-500 GHz band, we verify the rationality of the algorithm and demonstrate its applicability. Through the combination of the two methods, the terahertz dielectric properties of a majority of flat non-conducting solid materials and non-polar liquid materials can be measured.

  16. Novel technique to measure the polarizability of the nucleon

    Energy Technology Data Exchange (ETDEWEB)

    Yevetska, Olena; Richter, Achim; Schrieder, Gerhard; Watzlawik, Steffen [Institut fuer Kernphysik, Technische Universitaet Darmstadt (Germany); Ahrens, Juergen [Institut fuer Kernphysik, Johannes Gutenberg-Universitaet, Mainz (Germany); Chizhov, Vladimir; Iatsioura, Valeriy; Maev, Evgeniy; Orishchin, Evgeniy; Petrov, Gennadiy; Sergeev, Lev; Smirenin, Yuriy [Petersburg Nuclear Physics Institute, Petersburg (Russian Federation)

    2008-07-01

    At the Superconducting Darmstadt electron linear accelerator S-DALINAC an experiment has been built to measure the electric and magnetic polarizability of the proton and the deuteron by low energy Compton scattering with the aim to determine the energy dependence of the differential cross sections of elastic {gamma}p/{gamma}d scattering at two angles in a model-independent way in the photon energy range 20-100 MeV with a precision < 1%. A narrow collimated bremsstrahlung photon beam enters two high pressure ionisation chambers filled with hydrogen, which act as target as well as detector gas. Two large volume NaI-spectrometers detect the Compton scattered photons under angles of 90 and 130 and serve as triggers for coincidence measurements of the recoiling nucleons in the chambers. First experiments were carried out using electron beams of 60 and 79 MeV, respectively. Results based on pulse shape analysis are presented.

  17. Optical Measurement Techniques for Optical Fiber and Waveguide Devices

    Institute of Scientific and Technical Information of China (English)

    D.Y.; Kim; Y.; Park; N.H.; Seong; Y.C.Youk; J.Y.; Lee; S.; Moon; I.H.; Shin; H.S.; Ryu

    2003-01-01

    We describe three major optical characterization methods for fiber and fiber devices. A simple servo controlled scanning fiber-optic confocal microscope is proposed for determining the refractive index profile of an optical fiber. To measure the chromatic dispersion of a short length fiber a Mach-Zehnder fiber interferometer with a novel interferometric distance meter is introduced. At the end, a tomographic method is demonstrated for determining the 2-D stress profile of a fiber.

  18. Measuring 35S of Aerosol Sulfate: Techniques and First Results

    Science.gov (United States)

    Brothers, L. A.; Dominguez, G.; Bluen, B.; Corbin, A.; Abramian, A.; Thiemens, M. H.

    2007-12-01

    On a global and regional level, the cycling of sulfur in the environment has consequences for air quality, human health, and may contribute to global climate change. Due to its multiple oxidation states, the sulfur cycle is very complex and poorly understood. Stable isotopes are currently used to understand reaction pathways as well as sources and sinks of sulfurous compounds in the environment. Sulfur also has one short lived (τ1/2 ~87 d) radioactive isotope (35S) which is continuously made in the atmosphere by the cosmic ray spallation of argon, is then quickly oxidized to 35SO2 and enters the atmospheric sulfur cycle. The short-lived radioactive nature of this isotope of sulfur provides us with potentially powerful tracer for understanding the time scales at which sulfur is oxidized, deposited, and transported in the atmosphere and the deposition of atmospheric sulfate into rivers and water catchments. However, despite its potential, the use of 35S as a tracer of aerosol chemistry has not been fully exploited, Here we present details of instrumental set up for measuring 35S in aerosol sulfate and some preliminary results of measurements of 35S abundances in aerosols from Riverside (inland) and La Jolla (coastal) CA and discuss the sensitivity and limitations of the measurements in providing insights into day/night aerosol chemistry (Riverside) as well as the uptake of SO2 pollution in coastal environments by sea-salt aerosols. Also, we present preliminary results from measurement of sulfate in river water in Ecuador before and after precipitation events.

  19. A Survey of Advanced Microwave Frequency Measurement Techniques

    OpenAIRE

    Anand Swaroop Khare,

    2012-01-01

    Microwaves are radio waves with wavelengths ranging from as long as one meter to as short as one millimeter, or equivalently, with frequencies between 300 MHz and 300 GHz. The science of photonics includes the generation, emission, modulation, signal processing, switching, transmission, amplification, detection and sensing of light. Microwave photonics has been introduced for achieving ultra broadband signal processing. Instantaneous Frequency Measurement (IFM) receivers play an important ro...

  20. Technique for Performing Dielectric Property Measurements at Microwave Frequencies

    Science.gov (United States)

    Barmatz, Martin B.; Jackson, Henry W.

    2010-01-01

    A paper discusses the need to perform accurate dielectric property measurements on larger sized samples, particularly liquids at microwave frequencies. These types of measurements cannot be obtained using conventional cavity perturbation methods, particularly for liquids or powdered or granulated solids that require a surrounding container. To solve this problem, a model has been developed for the resonant frequency and quality factor of a cylindrical microwave cavity containing concentric cylindrical samples. This model can then be inverted to obtain the real and imaginary dielectric constants of the material of interest. This approach is based on using exact solutions to Maxwell s equations for the resonant properties of a cylindrical microwave cavity and also using the effective electrical conductivity of the cavity walls that is estimated from the measured empty cavity quality factor. This new approach calculates the complex resonant frequency and associated electromagnetic fields for a cylindrical microwave cavity with lossy walls that is loaded with concentric, axially aligned, lossy dielectric cylindrical samples. In this approach, the calculated complex resonant frequency, consisting of real and imaginary parts, is related to the experimentally measured quantities. Because this approach uses Maxwell's equations to determine the perturbed electromagnetic fields in the cavity with the material(s) inserted, one can calculate the expected wall losses using the fields for the loaded cavity rather than just depending on the value of the fields obtained from the empty cavity quality factor. These additional calculations provide a more accurate determination of the complex dielectric constant of the material being studied. The improved approach will be particularly important when working with larger samples or samples with larger dielectric constants that will further perturb the cavity electromagnetic fields. Also, this approach enables the ability to have a

  1. Probing Radiation Damage in Plutonium Alloys with Multiple Measurement Techniques

    Energy Technology Data Exchange (ETDEWEB)

    McCall, S K; Fluss, M J; Chung, B W

    2010-04-21

    A material subjected to radiation damage will usually experience changes in its physical properties. Measuring these changes in the physical properties provides a basis to study radiation damage in a material which is important for a variety of real world applications from reactor materials to semiconducting devices. When investigating radiation damage, the relative sensitivity of any given property can vary considerably based on the concentration and type of damage present as well as external parameters such as the temperature and starting material composition. By measuring multiple physical properties, these differing sensitivities can be leveraged to provide greater insight into the different aspects of radiation damage accumulation, thereby providing a broader understanding of the mechanisms involved. In this report, self-damage from {alpha}-particle decay in Pu is investigated by measuring two different properties: magnetic susceptibility and resistivity. The results suggest that while the first annealing stage obeys second order chemical kinetics, the primary mechanism is not the recombination of vacancy-interstitial close pairs.

  2. A surface wave elastography technique for measuring tissue viscoelastic properties.

    Science.gov (United States)

    Zhang, Xiaoming

    2017-04-01

    A surface wave elastography method is proposed to study the viscoelastic properties of skin by measuring the surface wave speed and attenuation on the skin. Experiments were carried out on porcine skin tissues. The surface wave speed is measured by the change of phase with distance. The wave attenuation is measured by the decay of wave amplitude with distance. The change of viscoelastic properties with temperature was studied at room and body temperatures. The wave speed was 1.83m/s at 22°C but reduced to 1.52m/s at 33°C. The viscoelastic ratio was almost constant from 22°C to 33°C. Fresh and decayed tissues were studied. The wave speed of the decayed tissue increased from 1.83m/s of fresh state to 2.73m/s. The viscoelastic ratio was 0.412/mm at the decayed state compared to 0.215/mm at the fresh state. More tissue samples are needed to study these viscoelastic parameters according to specific applications.

  3. Measuring information technology investment among Canadian academic health sciences centres.

    Science.gov (United States)

    Pederson, Lorraine; Leonard, Kevin

    2005-01-01

    Many recent studies have attempted to accurately measure the expenditure by hospitals in the area of new information technology (IT), for example see Leonard 1998 and Pink et al. 2001. This is usually done as an exercise to compare the healthcare sector with other industries that have had much more success in implementing and leveraging their IT investment (Willcocks 1992; Chan 2000). It is normally hoped that such investigation would help explain some of the differences among the various industries and provide insight into where (and how much) future IT spending should occur in healthcare (Leonard 2004). Herein, we present the results from a study of eight Canadian academic health sciences centres that contributed data in order to analyze the amount of information technology spending in their organizations. Specifically, we focus on one specific indicator: the IT spend ratio. This ratio is defined as the percentage of total IT net costs to total hospital net operating costs, and aims to provide a "relative (or percentage) measure of spending" so as to make the comparisons meaningful. One such comparison shows that hospitals spend only 55% of the amount the financial services sector spends.

  4. Limitations caused by distortion in room impulse response measurements by swept sine technique

    DEFF Research Database (Denmark)

    Stojic, Branko; Ciric, Dejan; Markovic, Milos

    2011-01-01

    by the distortion in room impulse response measurements by swept sine technique are analyzed here by the simulations and measurements. For the investigation, both linear and exponential swept sines are used as an excitation signal. In the simulations, this signal is modified by the nonlinearity model in the time...... of a measured response can be limited in a similar way as in maximum length sequence technique, although the saturation level (maximum dynamic range) is higher for swept sine technique. Thus, swept sine technique is also vulnerable to a certain extent to distortion that limits the quality of measured impulse...

  5. Evaluation of the measurement geometries and data processing algorithms for industrial gamma tomography technology

    Energy Technology Data Exchange (ETDEWEB)

    Lee, N.Y. [Radioisotope Research Division, Korea Atomic Energy Research Institute, P.O. Box 105, Yuseong, Daejeon 305-353 (Korea, Republic of)], E-mail: nayoung4493@gmail.com; Jung, S.H. [Radioisotope Research Division, Korea Atomic Energy Research Institute, P.O. Box 105, Yuseong, Daejeon 305-353 (Korea, Republic of)], E-mail: shjung3@kaeri.re.kr; Kim, J.B. [Radioisotope Research Division, Korea Atomic Energy Research Institute, P.O. Box 105, Yuseong, Daejeon 305-353 (Korea, Republic of)], E-mail: jong@kaeri.re.kr

    2009-07-15

    In this paper, we evaluated the measurement geometries and data processing algorithms for industrial gamma tomography technology. Several phantoms simulating industrial objects were tested in various conditions with the gamma-ray CT system developed in KAERI (Korea Atomic Energy Research Institute). Radiation was measured with lead shielded 24 1x1 in Nal detectors. Regarding the parallel beam geometry, the EM algorithm showed the best resolution among the algebraic reconstruction technique (ART), simultaneous iterative reconstructive technique (SIRT) and expectation maximization (EM). However, the fan beam scanning was more time efficient than the parallel projection for the similar quality of reconstructed image. Future developments of the industrial gamma ray CT will be focused on a large-scale application which is more practical for a diagnosis in the petrochemical industry.

  6. Measurement of pharyngeal sensory cortical processing: technique and physiologic implications

    Directory of Open Access Journals (Sweden)

    Ringelstein E Bernd

    2009-07-01

    Full Text Available Abstract Background Dysphagia is a major complication of different diseases affecting both the central and peripheral nervous system. Pharyngeal sensory impairment is one of the main features of neurogenic dysphagia. Therefore an objective technique to examine the cortical processing of pharyngeal sensory input would be a helpful diagnostic tool in this context. We developed a simple paradigm to perform pneumatic stimulation to both sides of the pharyngeal wall. Whole-head MEG was employed to study changes in cortical activation during this pharyngeal stimulation in nine healthy subjects. Data were analyzed by means of synthetic aperture magnetometry (SAM and the group analysis of individual SAM data was performed using a permutation test. Results Our results revealed bilateral activation of the caudolateral primary somatosensory cortex following sensory pharyngeal stimulation with a slight lateralization to the side of stimulation. Conclusion The method introduced here is simple and easy to perform and might be applicable in the clinical setting. The results are in keeping with previous findings showing bihemispheric involvement in the complex task of sensory pharyngeal processing. They might also explain changes in deglutition after hemispheric strokes. The ipsilaterally lateralized processing is surprising and needs further investigation.

  7. Techniques for Measurement of Nitrate Movement in Soils

    Science.gov (United States)

    Broadbent, F. E.

    1971-01-01

    Contamination of surface and ground waters with nitrate usually involves leaching through soil of nitrate produced by mineralization of soil organic matter, decomposition of animal wastes or plant residues, or derived from fertilizers. Nitrate concentrations in the soil solution may be measured by several chemical procedures or by the nitrate electrode. since nitrate is produced throughout the soil mass it is difficult to identify a source of nitrate contamination by conventional means. This problem can be solved by use of N-15-enriched or N-15-depleted materials as tracers. The latter is particularly attractive because of the negligible possibility of the tracer hazardous to health.

  8. Review of geotechnical measurement techniques for a nuclear waste repository in bedded salt

    Energy Technology Data Exchange (ETDEWEB)

    1979-12-01

    This report presents a description of geotechnical measurement techniques that can provide the data necessary for safe development - i.e., location, design, construction, operation, decommissioning and abandonment - of a radioactive waste repository in bedded salt. Geotechnical data obtained by a diversity of measurement techniques are required during all phases of respository evolution. The techniques discussed in this report are grouped in the following categories: geologic, geophysical and geodetic; rock mechanics; hydrologic, hydrogeologic and water quality; and thermal. The major contribution of the report is the presentation of extensive tables that provide a review of available measurement techniques for each of these categories. The techniques are also discussed in the text to the extent necessary to describe the measurements and associated instruments, and to evaluate the applicability or limitations of the method. More detailed discussions of thermal phenomena, creep laws and geophysical methods are contained in the appendices; references to detailed explanations of measurement techniques and instrumentation are inluded throughout the report.

  9. [In situ temperature measurement by absorption spectroscopy based on time division multiplexing technology].

    Science.gov (United States)

    Lou, Nan-zheng; Li, Ning; Weng, Chun-sheng

    2012-05-01

    Tunable diode laser absorption spectroscopy (TDLAS) technology is a kind of high sensitivity, high selectivity of non contacting gas in situ measurement technique. In the present paper, in situ gas temperature measurement of an open environment was achieved by means of direct scanning multiple characteristic lines of H2O and combined with least-squares algorithm. Through the use of HITRAN spectral database, the boundary effect on the gas temperature and concentration measurements was discussed in detail, and results showed that the combination of scanning multiple characteristic lines and least-squares algorithm can effectively reduce the boundary effect on the gas temperature measurements under the open environment. Experiments using time division multiplexing technology to simultaneously scan 7444.36, 7185.60, 7182.95 and 7447.48 cm(-1), the four characteristic H2O lines, the gas temperature of tubular furnace in the range of 573-973 K was measured under different conditions. The maximum temperature difference between absorption spectrum measurement and thermocouple signal was less than 52.4 K, and the maximum relative error of temperature measurement was 6.8%.

  10. Measuring Technique of Bubble Size Distributions in Dough

    Science.gov (United States)

    Maeda, Tatsurou; Do, Gab-Soo; Sugiyama, Junichi; Oguchi, Kosei; Tsuta, Mizuki

    A novel technique to recognize bubbles in bread dough and analyze their size distribution was developed by using a Micro-Slicer Image Processing System (MSIPS). Samples were taken from the final stage of the mixing process of bread dough which generally consists of four distinctive stages. Also, to investigate the effect of freeze preservation on the size distribution of bubbles, comparisons were made between fresh dough and the dough that had been freeze preserved at .30°C for three months. Bubbles in the dough samples were identified in the images of MSIPS as defocusing spots due to the difference in focal distance created by vacant spaces. In case of the fresh dough, a total of 910 bubbles were recognized and their maximum diameter ranged from 0.4 to 70.5μm with an average of 11.1μm. On the other hand, a total of 1,195 bubbles were recognized from the freeze-preserved sample, and the maximum diameter ranged from 0.9 to 32.7μm with an average of 6.7μm. Small bubbles with maximum diameters less than 10μm comprised approximately 59% and 78% of total bubbles for fresh and freeze-preserved dough samples, respectively. The results indicated that the bubble size of frozen dough is smaller than that of unfrozen one. The proposed method can provide a novel tool to investigate the effects of mixing and preservation treatments on the size, morphology and distribution of bubbles in bread dough.

  11. Ultra-filtration measurement using CT imaging technology

    Energy Technology Data Exchange (ETDEWEB)

    Lu Junfeng [Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, No.2 Beiyitiao Street, Zhongguancun, Haidian District, Beijing, 100190 (China); Lu Wenqiang, E-mail: junfenglu@mail.ipc.ac.c [Graduate University of Chinese Academy of Sciences, No.19A Yuquan Road, Shijingshan District, Beijing, 100049 (China)

    2009-02-01

    As a functional unit in the hemodialysis process, dialyzer captured quite a few medical research interests since 1980s. In the design of dialyzer or in the ongoing hemodialysis process, to estimate the ultra-filtration amount of a dialyzer, the sideway loss of the running blood flow through hollow fibers or filtration channels should be measured. This further leads to the measurement of the blood flow inside the dialyzer. For this measurement, a non-invasive method is highly desired because of the high-dense bundled hollow fibers or packed channels inside the dialyzer. As non-invasive measurement tools, CT (Computed Tomography) technologies were widely used for tissue, bone, and cancerous clinical analyses etc .... Thus, in this paper, a CT system is adopted to predict the blood flow inside a hollow fiber dialyzer. In view of symmetric property of the hollow fiber dialyzer, the largest cutting plane that parallels to the cylindrical dialyzer was analyzed by the CT system dynamically. And then, a noninvasive image analysis method used to predict the ultra-filtration amount is proposed.

  12. Evaluation of open path measuring techniques for petrochemicals NMVOC emissions : DIAL applications in Sweden and Texas

    Energy Technology Data Exchange (ETDEWEB)

    Cuclis, A.; Frisch, L.; Byun, D. [Houston Univ., Houston, TX (United States)

    2003-07-01

    Various emissions factors have been used over the past twenty years to calculate the emissions of volatile organic compounds (VOC) generated by refineries and chemical plants. Emissions inventories in Canada, the United States and Europe are created based on these estimating techniques. Petrochemical facilities have at their disposal the following 4 open path spectroscopic methods for measuring VOCs: Open Path Fourier Transform Infrared (OP-FTIR), Differential Optical Absorption Spectroscopy (DOAS), Tunable Diode Laser Absorption Spectroscopy (TDLAS), and Differential Absorption Light Detection and Ranging (DIAL LIDAR or DIAL). The authors reviewed the 4 open path techniques and evaluated their ability to produce results for the creation of accurate accounting of VOCs in petrochemical facilities. The application of DIAL technology in both Sweden (Scanraff refinery in Lysekil, the largest in Sweden) and Texas (Houston-Gavelston area) to identify emissions was discussed in detail. The capability of creating two- and three-dimensional plots of concentrations and identifying the locations of leaks or hot spots is a major advantage of DIAL, even if it remains an expensive and complicated solution. The advantage of OP-FTIR is to be able to speciate several different compounds in a VOC filled atmosphere. However, a number of interfering compounds are also present adding to the difficulty of proper field operation. Capable of achieving very low detection limits, DOAS is the simplest of the technologies, but it has the disadvantage of identifying fewer compounds than OP-FTIR or DIAL. The most accurate technology for the identification of specific species is TDLAS with its high resolution. The requirement to generally use a separate laser for each component to be measured is a drawback. A separate transmitter and detector, or the use of retro-reflectors to return the signal back to the detector is required for OP-FTIR, DOAS and TDLAS. Reflections from particles in the gas

  13. Technology development for nuclear material measurement and accountability

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Jong Sook; Lee, Byung Doo; Cha, Hong Ryul; Lee, Yong Duk; Choi, Hyung Nae; Nah, Won Woo; Park, Hoh Joon; Lee, Yung Kil [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-12-01

    The measurement techniques for Pu samples and spent fuel assembly were developed in support of the implementation of national inspection responsibility under the Atomic Energy Act promulgated in 1994 and a computer program was also developed to assess the total nuclear material balance by facility declared records. The results of plutonium isotopic determination by gamma-ray spectrometry with high resolution germanium detector with peak analysis codes (FRAM and MGA codes) were approached to within 1% {approx} 2% of error from chemical analysis values by mass spectrometry. A gamma-ray measurement system for underwater spent nuclear fuels was developed and tested successfully. The falsification of facility and state records can be traced with the help of the developed computer code against declared reports submitted by the concerned state. This activity eventually resulted in finding the discrepancy of accountability records. 18 figs, 20 tabs, 27 refs. (Author).

  14. Techniques for Galactic Dust Measurements in the Heliosphere

    CERN Document Server

    Grün, E; Horányi, M; Kissel, J; Krüger, H; Srama, R A; Svedhem, H; Withnell, P; Grün, Eberhard; Landgraf, Markus; Horány, Mihaly; Kissel, Jochen; Krüger, Harald; Srama, Ralf; Withnell, Peter

    1999-01-01

    Galactic interstellar dust (ISD) is the major ingredient in planetary formation. However, information on this important material has been extremely limited. Recently the Ulysses dust detector has identified and measured interstellar dust outside 1.8~AU from the Sun at ecliptic latitudes above $50^{\\circ}$. Inside this distance it could not reliably distinguish interstellar from interplanetary dust. Modeling the Ulysses data suggests that up to 30 % of dust flux with masses above $10^{-16}\\rm kg$ at 1~AU is of interstellar origin. From the Hiten satellite in high eccentric orbit about the Earth there are indications that ISD indeed reaches the Earth's orbit. Two new missions carrying dust detectors, Cassini and Stardust, will greatly increase our observational knowledge. In this paper we briefly review instruments used on these missions and compare their capabilities. The Stardust mission [{\\em Brownlee et al.}, 1996] will analyze the local interstellar dust population by an in-situ chemical analyzer and colle...

  15. Exchange Flow Rate Measurement Technique in Density Different Gases

    Directory of Open Access Journals (Sweden)

    Motoo Fumizawa

    2012-04-01

    Full Text Available Buoyancy-driven exchange flows of helium-air through inclined a narrow tube was investigated. Exchange flows may occur following the opening of a window for ventilation, as well as when a pipe ruptures in a high temperature gas-cooled reactor. The experiment in this paper was carried out in a test chamber filled with helium and the flow was visualized using the smoke wire method. A high-speed camera recorded the flow behavior. The image of the flow was transferred to digital data, and the slow flow velocity, i.e. micro flow rate was measured by PIV software. Numerical simulation was carried out by the code of moving particle method with Lagrange method.

  16. Technique for measuring carbon monoxide uptake in mice

    Energy Technology Data Exchange (ETDEWEB)

    Depledge, M.H.; Collis, C.H.; Chir, B.; Barrett, A.

    1981-04-01

    A new method has been developed for measuring carbon monoxide (CO) uptake in mice. Each animal was placed in a syringe and allowed to rebreathe a mixture of CO and helium (He) for 60 s. CO uptake was detemined from a comparison of CO and He concentrations before and after rebreathing. Weight specific CO uptake increased with body weight in CBA mice weighing between 20 to 35 gr. In larger mice, size dependence was less marked, although a slight fall in CO uptake was observed in older animals. Anaesthesia reduced ventilatory rate and CO uptake to a variable extent. The method is reproducible, non-invasive and does not require anaesthesia; consequently, it can be used to study serial changes in lung function. It is sensitive enough to detect lung damage in CBA mice following 16 Gy total body irradiation. Values of diffusing capacity obtained for mice using this method are consistent with published values.

  17. Diffuse scattering measurements with synchrotron radiation: Instrumentation and techniques

    Energy Technology Data Exchange (ETDEWEB)

    Matsubara, E.; Georgopoulos, P.

    1985-12-01

    The analysis of diffuse scattering from single crystalline specimens in the reflection mode has generally been acknowledged as a very powerful means of obtaining structural information on local atomic arrangements in disordered alloys, intermetallics and ceramics. However, owing to the low intensities encountered and the large number of measurements required for such an analysis, experiments have been extremely time consuming and few have been attempted. Synchrotron radiation makes it possible to conduct such experiments in a matter of hours and much higher quality data can be obtained than in the laboratory. This paper describes the experimental procedures and methods applied to a study of Al-Cu age hardening alloys conducted at the Cornell Synchrotron Source (CHESS). (orig.).

  18. Optical technique for measurement of random water wave surfaces

    Science.gov (United States)

    Sorrell, F. Y.; Withers, A. L.

    1976-01-01

    An optical system using the refraction of a vertical light ray has been developed for measuring the slope of random wind-generated water waves. The basic elements of the system are photovoltaic cells which are connected to individual amplifiers so that when the refracted light beam is incident on a cell, the output of the cell is amplified and then supplied as input to a comparator. The comparator then provides a specified voltage output, independent of the incident light intensity, as long as it is above a designated background value. The comparators are designed to give output voltages comparable with standard TTL. This arrangement provides a high signal from the cell when it experiences incident light, and a low signal when there is only background light, with the high and low signals at TTL voltage levels.

  19. The capacitive sensor for liquid level measurement, fabricated with the inkjet printing technology

    Science.gov (United States)

    Paczesny, Daniel; Tarapata, Grzegorz; Marzecki, Michał; Woyke, Michał; Jachowicz, Ryszard

    2016-11-01

    The paper reports a capacitive multisection sensor for measuring level of various liquids. Presented sensor was fully fabricated with the inkjet printing technology on thin Kapton substrate. The measurement of liquids level based on capacitive sensing is already well known technique, however the novelty of presented sensor is the technology of fabrication that was used, approach to the pattern design which combines analog and digital capacitive section and obtained self-calibration feature of whole system independently on measured liquid type. Fabricated sensor structure has dimension of 210 mm x 12 mm and the thickness approximately of 27 μm. It contains 8 digital-like sections along the sensor and one analog section which allows to fine measurements. The sensor was tested in a vessel during filling and emptying with various liquids. Performed tests exhibited the linearity of the sensor characteristic and the lack of hysteresis. Obtained sensitivity of the sensor prototype was approximately 6.8 pF/mm, but it could be easily modify on the design stage due to the fast prototyping feature of inkjet printing technology. Thanks to the flexibility of the substrate, the sensor structure can be applied to any shape of vessel. Furthermore, the sensor construction is fairly simple and costs in mass production could be extremely low. This type of sensor was design especially for autonomous cleaning and washing robots for large areas operation.

  20. Extensional bundle waveguide techniques for measuring flow of hot fluids.

    Science.gov (United States)

    Lynnworth, Lawrence C; Liu, Yi; Umina, John A

    2005-04-01

    A bundle of acoustically slender metal rods, each thin compared to wavelength, tightly packed within a sheath, and welded closed at each end, provides a dispersion-free waveguide assembly that acts as a thermal buffer between a transducer and the hot fluid medium the flow of which is to be measured. Gas and steam flow applications have ranged up to 600 degrees C. Liquid applications have ranged from cryogenic (-160 degrees C) to 500 degrees C and include intermittent two-phase flows. The individual rods comprising the bundle usually are approximately one millimeter in diameter. The sheath, made of a pipe or tube, typically has an outside diameter of 12.7 to about 33 mm and usually is about 300 mm long. Materials for the sheath and bundle are selected to satisfy requirements of compatibility with the fluid as well as for acoustic properties. Corrosion-resistant alloys such as 316SS and titanium are commonly used. The buffers are used with transducers that are metal-encapsulated and certified for use in hazardous areas. They operate at a frequency in the range of 0.1 to 1 MHz. The radiating end of the buffer is usually flat and perpendicular to the buffer's main axis. In some cases the end of the buffer is stepped or angled. Angling the radiating faces at approximately 2 degrees to overcome beam drift at Mach 0.1 recently contributed to solving a high-temperature high-velocity flow measurement problem. The temperature in this situation was 300 degrees C, and the gas molecular weight was about 95, with pressure 0.9 to 1.1 bar.

  1. Measurement uncertainty on subsurface defects detection using active infrared thermographic technique

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Yoon Jae; Kim [Kongju National University, Cheonan (Korea, Republic of); Choi, Won Jae [Center for Safety Measurements, Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2015-10-15

    Active infrared thermography methods have been known to possess good fault detection capabilities for the detection of defects in materials compared to the conventional passive thermal infrared imaging techniques. However, the reliability of the technique has been under scrutiny. This paper proposes the lock-in thermography technique for the detection and estimation of artificial subsurface defect size and depth with uncertainty measurement.

  2. New technology for transmission measurements in process pipes.

    Science.gov (United States)

    Moss, C E; Favalli, A; Goda, J M; Ianakiev, K D; Lombardi, M; McCluskey, C W; Paffett, M T; Swinhoe, M T

    2013-02-01

    Transmission measurements of radiation through process pipes provide a non-intrusive method of determining the amount of product present in the pipes. The product could be a liquid, a slurry, or a gas, which is the most challenging because of the low density. Traditionally, these techniques have used a radioactive source that has to be replaced periodically. We have developed a transmission technique based on an X-ray tube instead of a decaying source. A notch filter is used to provide a narrow transmission line, and a thin silicon transmission detector is used to monitor the X-ray tube output. The transmitted X-rays are measured with a high-throughput gamma spectrometer that consists of a NaI(Tl) detector and an MCA with precise dead time correction. This spectrometer provides stable transmission measurements with an accuracy of a fraction of a percent. The shielding and collimator are made of machinable tungsten for thermal mechanical stability, as well low-cost, low-weight tungsten powder in polymer castings. We describe two methods of measuring the pipe wall thickness without evacuating the pipe. Our particular application was for enrichment monitors for UF(6) in process pipes. Enrichment monitors that are independent of the plant data require two measurements: a transmission measurement to determine the total amount of uranium in the pipe and a measurement of the 186-keV gamma-ray line to determine the amount of (235)U present. The ratio of these values gives the enrichment. Previous designs used a decaying radioactive source such as (57)Co (122 keV, T(½)=272 days) or (109)Cd (22 keV, T(½)=1.2 years). A major effort was required to access and periodically replace these sources in operating plants. In this report, we describe the use of an X-ray tube, which eliminated the source problem, and other innovations. Then we present data from an enrichment monitor that incorporates these innovations.

  3. Digital instantaneous frequency measurement technique utilising high-speed ADC’s and FPGA’s

    CSIR Research Space (South Africa)

    Herselman, PL

    2006-02-27

    Full Text Available This paper presents the Digital Instantaneous Frequency Measurement (DIFM) technique, which can measure the carrier frequency of a received waveform within a fraction of a microsecond. The resulting frequency range, resolution and accuracy...

  4. A Novel Technique to Measure Gain Spectrum for Fabry-Pérot Semiconductor Lasers

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    A novel gain measurement technique based on the integration of the measured amplified spontaneous emission spectrum multiplying a phase function over one longitudinal mode interval is proposed for Fabry-Perot semiconductor lasers.

  5. AN OVERVIEW OF POWER DISSIPATION AND CONTROL TECHNIQUES IN CMOS TECHNOLOGY

    Directory of Open Access Journals (Sweden)

    N. B. ROMLI

    2015-03-01

    Full Text Available Total power dissipation in CMOS circuits has become a huge challenging in current semiconductor industry due to the leakage current and the leakage power. The exponential growth of both static and dynamic power dissipations in any CMOS process technology option has increased the cost and efficiency of the system. Technology options are used for the execution specifications and usually it depends on the optimisation and the performance constraints over the chip. This article reviews the relevant researches of the source or power dissipation, the mechanism to reduce the dynamic power dissipation as well as static power dissipation and an overview of various circuit techniques to control them. Important device parameters including voltage threshold and switching capacitance impact to the circuit performance in lowering both dynamic and static power dissipation are presented. The demand for the reduction of power dissipation in CMOS technology shall remain a challenging and active area of research for years to come. Thus, this review shall work as a guideline for the researchers who wish to work on power dissipation and control techniques.

  6. Measurement of Pipe Slope with Laser Scanning Technique

    Energy Technology Data Exchange (ETDEWEB)

    Lee, D. Y.; Jeon, S. S.; Hong, S. J. [FNC Technology Co., Seoul National University, Seoul (Korea, Republic of); Park, S. C. [Enguard Co., Seoul (Korea, Republic of)

    2011-10-15

    U.S. Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 2008-01 which provides recommendation and guidance to nuclear power plants for managing gas intrusion and accumulation in safety systems such as Emergency Core Cooling (ECC), Decay Heat Removal (DHR) and Containment Spray (CS) systems. Following the GL2008-01, Nuclear Energy Institute (NEI) reported NEI 09-10 that gives industry guidance for effective prevention and management of system gas accumulation. The location of gas accumulation is usually a high point of piping systems. The high point of system is easily identified by investigating as-built isometric drawings of the subjected systems. However, the real plant piping configuration such as a slope might be different from as-built drawings. If there is a small slope on pipe which is a horizontal configuration in as-built drawing, gas can be accumulated at the high point in pipes with wrong slope as shown in Fig. 1. This paper demonstrates a feasibility to measure the slope of piping systems by using the laser scanning and presents a simple example

  7. The Kety-Schmidt Technique for Quantitative Perfusion and Oxygen Metabolism Measurements in the MR Environment

    Science.gov (United States)

    Lee, John J.; Powers, William J.; Faulkner, Chad B.; Boyle, Patrick J.; Derdeyn, Colin P.

    2013-01-01

    The Kety-Schmidt technique provides quantitative measurement of whole brain cerebral blood flow (CBF). CBF is measured as the area between the arterial and venous washout curves of a diffusible tracer. Oxygen extraction and metabolism may be calculated from arterial and venous samples. In this report we present a method for performing these measurements in an MR environment. This technique could be useful for validation of MR methods of hemodynamic and metabolic measurements in humans. PMID:22997166

  8. EDITORIAL: Announcing the 2012 Measurement Science and Technology Outstanding Paper Awards Announcing the 2012 Measurement Science and Technology Outstanding Paper Awards

    Science.gov (United States)

    Foss, John; Dewhurst, Richard; Yacoot, Andrew; Regtien, Paul; Peters, Kara

    2013-07-01

    Since 1991, Measurement Science and Technology has awarded a Best Paper prize. The Editorial Board of this journal believes that such a prize is an opportunity to thank authors for submitting their work, and serves as an integral part of the on-going quality review of the journal. The current breadth of topical areas that are covered by MST has made it advisable to expand the recognition of excellent publications. Hence, since 2005 the Editorial Board have presented 'Outstanding Paper Awards'. This year awards were presented in the areas of 'Measurement Science' and 'Fluid Mechanics'. Although the categories mirror subject sections in the journal, the Editorial Board consider articles from all categories in the selection process. 2012 Award Winners—Measurement Science Physical characterization and performance evaluation of an x-ray micro-computed tomography system for dimensional metrology applications J Hiller1, M Maisl2 and L M Reindl3 1 Department of Mechanical Engineering, Technical University of Denmark (DTU), Produktionstorvet, Building 425, 2800 Kgs Lyngby, Denmark 2 Development Center for X-Ray Technology (EZRT), Fraunhofer Institute for Non-Destructive Testing (IZFP), Campus E3 1, 66123 Saarbrücken, Germany 3 Laboratory for Electrical Instrumentation, Institute for Microsystem Technology (IMTEK), University of Freiburg, Georges-Köhler-Allee 103, 79110 Freiburg, Germany This year's award goes to another paper [1] dealing with micro-measurements, using a scientific measurement technique that is both old and traditional. However, it is the advent of modern technology with computational techniques that have offered new insights into the capability of the measurement method. The paper describes an x-ray computed tomography (CT) system. Such systems are increasingly used in production engineering, where non-destructive measurements of the internal geometries of workpieces can be made with high information density. CT offers important alternatives to tactile

  9. Advanced Measurement and Modeling Techniques for Improved SOFC Cathodes

    Energy Technology Data Exchange (ETDEWEB)

    Stuart Adler; L. Dunyushkina; S. Huff; Y. Lu; J. Wilson

    2006-12-31

    The goal of this project was to develop an improved understanding of factors governing performance and degradation of mixed-conducting SOFC cathodes. Two new diagnostic tools were developed to help achieve this goal: (1) microelectrode half-cells for improved isolation of cathode impedance on thin electrolytes, and (2) nonlinear electrochemical impedance spectroscopy (NLEIS), a variant of traditional impedance that allows workers to probe nonlinear rates as a function of frequency. After reporting on the development and efficacy of these tools, this document reports on the use of these and other tools to better understand performance and degradation of cathodes based on the mixed conductor La{sub 1-x}Sr{sub x}CoO{sub 3-{delta}} (LSC) on gadolinia or samaria-doped ceria (GDC or SDC). We describe the use of NLEIS to measure O{sub 2} exchange on thin-film LSC electrodes, and show that O{sub 2} exchange is most likely governed by dissociative adsorption. We also describe parametric studies of porous LSC electrodes using impedance and NLEIS. Our results suggest that O{sub 2} exchange and ion transport co-limit performance under most relevant conditions, but it is O{sub 2} exchange that is most sensitive to processing, and subject to the greatest degradation and sample-to-sample variation. We recommend further work that focuses on electrodes of well-defined or characterized geometry, and probes the details of surface structure, composition, and impurities. Parallel work on primarily electronic conductors (LSM) would also be of benefit to developers, and to improved understanding of surface vs. bulk diffusion.

  10. Intercomparison of techniques for the non-invasive measurement of bone mass

    Energy Technology Data Exchange (ETDEWEB)

    Cohn, S.H.

    1981-01-01

    A variety of methods are presently available for the non-invasive measurement of bone mass of both normal individuals and patients with metabolic disorders. Chief among these methods are radiographic techniques such as radiogrammetry, photon absorptiometry, computer tomography, Compton scattering and neutron activation analysis. In this review, the salient features of the bone measurement techniques are discussed along with their accuracy and precision. The advantages and disadvantages of the various techniques for measuring bone mass are summarized. Where possible, intercomparisons are made of the various techniques.

  11. Opening the black box: measuring hospital information technology capability.

    Science.gov (United States)

    Burke, Darrell E; Menachemi, Nir

    2004-01-01

    Recently, health care investment in information technology (IT) has experienced a significant increase. Paralleling this increase has been an increase in IT capabilities. Despite the interest in and promises of IT in the health care setting, there is a paucity of empirical research that has attempted to define an organizational measure of IT capability. The dearth of research has contributed to the traditional belief that IT is perceived as a "black box," whereby organizational resources enter the box as "inputs" and are somehow transformed into positive outcomes for an organization. However, for positive outcomes to be realized, these outcomes must be measurable. This research uses a stakeholder perspective to develop a theoretically specified measure of IT capability. A latent construct, IT munificence, is proposed using tenets from diffusion of innovation theory and strategic contingency theory. The construct is tested using a sample of 1,545 acute care hospitals located in the United States. IT munificence fits the study data well, supporting the hypothesis that IT munificence represents a strategy of hospital IT capability.

  12. Innovative methodologies and technologies for thermal energy release measurement.

    Science.gov (United States)

    Marotta, Enrica; Peluso, Rosario; Avino, Rosario; Belviso, Pasquale; Caliro, Stefano; Carandente, Antonio; Chiodini, Giovanni; Mangiacapra, Annarita; Petrillo, Zaccaria; Sansivero, Fabio; Vilardo, Giuseppe; Marfe, Barbara

    2016-04-01

    Volcanoes exchange heat, gases and other fluids between the interrior of the Earth and its atmosphere influencing processes both at the surface and above it. This work is devoted to improve the knowledge on the parameters that control the anomalies in heat flux and chemical species emissions associated with the diffuse degassing processes of volcanic and hydrothermal zones. We are studying and developing innovative medium range remote sensing technologies to measure the variations through time of heat flux and chemical emissions in order to boost the definition of the activity state of a volcano and allowing a better assessment of the related hazard and risk mitigation. The current methodologies used to measure heat flux (i.e. CO2 flux or temperature gradient) are either poorly efficient or effective, and are unable to detect short to medium time (days to months) variation trends in the heat flux. Remote sensing of these parameters will allow for measurements faster than already accredited methods therefore it will be both more effective and efficient in case of emergency and it will be used to make quick routine monitoring. We are currently developing a method based on drone-born IR cameras to measure the ground surface temperature that, in a purely conductive regime, is directly correlated to the shallow temperature gradient. The use of flying drones will allow to quickly obtain a mapping of areas with thermal anomalies and a measure of their temperature at distance in the order of hundreds of meters. Further development of remote sensing will be done through the use, on flying drones, of multispectral and/or iperspectral sensors, UV scanners in order to be able to detect the amount of chemical species released in the athmosphere.

  13. Ice Detecting and Measuring Technologies on Power Lines

    Institute of Scientific and Technical Information of China (English)

    Liu Heyun; He Huiyong

    2005-01-01

    Ice detecting and measuring technologies used and developed for high voltage transmission lines are introduced in this paper. The Icing Rate Meter developed by Hydro-Quebec, working with the magnetostriction principle and regulated by an electronic control system is analyzed and the resonant piezoelectric transducers operated by a microprocessor-controlled electronic circuitry is also analyzed in great detail. It shows that the Icing Rate Meter (IRM) developed by Hydro-Quebec can record the occurrence and duration of icing events, but has two limitations: information on changes in the rate of icing within each hour is lost and the amount of time consumed during heating cycles is not taken into account.A resonant piezoelectric ice detector can automatically and distinctly sense ice and water films up to 0.5mm thick. It is a smart ice detection system, which might be used widely.

  14. Measuring Consumer Innovativeness: Identifying Innovators among Consumers of Modern Technologies

    Directory of Open Access Journals (Sweden)

    Jana Filová

    2015-12-01

    Full Text Available The methods currently used in innovation marketing research are focused on the late phases of the innovation process and are usually methodologically complex. This limits their practical impact. The presented work aims to create a simple self-report scale applicable in the initial and late phases of the innovation process, highly modular and suitable for a wide range of research. The main battery of questions was inspired by the adopter categorization by Rogers. The questions determine both (1 general characteristics of innovation adopters and (2 their relationship to a specific innovation. The scale was tested during robust longitudinal online research, thematically focused on users of modern technologies. A representative sample of 4,000 Internet users in the Czech Republic took part in the survey from 2013 to 2015. The result is a new self-report scale measuring consumer innovativeness applicable for prototyping, strategic decisions and effective communication of innovations to consumers.

  15. Simple counting technique for measuring mixtures of two pure beta-emitting radionuclides

    CSIR Research Space (South Africa)

    Van Wyngaardt, WM

    2006-08-01

    Full Text Available A simple counting technique to measure mixtures of two pure beta-emitting radionuclides is described. The method is based on elements of two liquid scintillation techniques that are widely used to measure single-radionuclide solutions, namely...

  16. Measuring free metal ion concentrations in multicomponent solutions using Donnan Membrane Technique

    NARCIS (Netherlands)

    Kalis, E.J.J.; Temminghoff, E.J.M.; Weng, L.P.; Riemsdijk, van W.H.

    2007-01-01

    Among speciation techniques that are able to measure free metal ion concentrations, the Donnan membrane technique (DMT) has the advantage that it can measure many different free metal ion concentrations simultaneously in a multicomponent sample. Even though the DMT has been applied to several system

  17. Measurement of bubble and pellet size distributions: past and current image analysis technology.

    Science.gov (United States)

    Junker, Beth

    2006-08-01

    Measurements of bubble and pellet size distributions are useful for biochemical process optimizations. The accuracy, representation, and simplicity of these measurements improve when the measurement is performed on-line and in situ rather than off-line using a sample. Historical and currently available measurement systems for photographic methods are summarized for bubble and pellet (morphology) measurement applications. Applications to cells, mycelia, and pellets measurements have driven key technological developments that have been applied for bubble measurements. Measurement trade-offs exist to maximize accuracy, extend range, and attain reasonable cycle times. Mathematical characterization of distributions using standard statistical techniques is straightforward, facilitating data presentation and analysis. For the specific application of bubble size distributions, selected bioreactor operating parameters and physicochemical conditions alter distributions. Empirical relationships have been established in some cases where sufficient data have been collected. In addition, parameters and conditions with substantial effects on bubble size distributions were identified and their relative effects quantified. This information was used to guide required accuracy and precision targets for bubble size distribution measurements from newly developed novel on-line and in situ bubble measurement devices.

  18. Development of detector technologies for neutron beta decay measurements

    Science.gov (United States)

    Choi, Jin Ha; Cude-Woods, Chris; Young, Albert; Los Alamos UCN Collaboration Collaboration

    2016-09-01

    In the past year we have developed two detector technologies for neutron beta decay measurements. The first is designed specifically to detect the recoil proton from neutron decay. In particular, the PERKEO III experiments planned for the Institut Laue Langevin require detectors with active area greater than about 600 cm2 area to achieve the targeted statistical sensitivity. We have developed an implementation of transmission foil detectors utilizing free standing foils of roughly 100 nm thickness and 700 cm2 area, coated with LiF converting crystal. These foils are placed in an accelerating electric field geometry to first accelerate the protons to 30 kV and then convert them to an electron shower which can be detected with conventional semiconductor or scintillator detectors. We've also begun development of technology that is designed to detect charged particles from neutron-capture reaction on 10B. The UCNtau experiment at the Los Alamos National Laboratories requires non-magnetic neutron sensors that can be used to measure the density of neutrons in a magnetic trap. We are employing a multilayer surface detector recently developed at Los Alamos for the UCN flux monitoring, adapting it for a compact, 1 cm2 detector and ultralow dark rates. The detector consists of 10B on ZnS scintillating sheet that will be adhered to both faces of an acrylic plate with scintillating optical fibers embedded into it. The optical fibers will be coupled to 2, Hamamatsu micro-PMTs for coincident detection of a neutron event.

  19. Feasibility of automated dropsize distributions from holographic data using digital image processing techniques. [particle diameter measurement technique

    Science.gov (United States)

    Feinstein, S. P.; Girard, M. A.

    1979-01-01

    An automated technique for measuring particle diameters and their spatial coordinates from holographic reconstructions is being developed. Preliminary tests on actual cold-flow holograms of impinging jets indicate that a suitable discriminant algorithm consists of a Fourier-Gaussian noise filter and a contour thresholding technique. This process identifies circular as well as noncircular objects. The desired objects (in this case, circular or possibly ellipsoidal) are then selected automatically from the above set and stored with their parametric representations. From this data, dropsize distributions as a function of spatial coordinates can be generated and combustion effects due to hardware and/or physical variables studied.

  20. Advanced bioimaging technologies in assessment of the quality of bone and scaffold materials. Techniques and applications

    Energy Technology Data Exchange (ETDEWEB)

    Qin Ling; Leung, Kwok Sui (eds.) [Chinese Univ. of Hong Kong (China). Dept. of Orthopaedics and Traumatology; Genant, H.K. [California Univ., San Francisco, CA (United States); Griffith, J.F. [Chinese Univ. of Hong Kong (China). Dept. of Radiology and Organ Imaging

    2007-07-01

    This book provides a perspective on the current status of bioimaging technologies developed to assess the quality of musculoskeletal tissue with an emphasis on bone and cartilage. It offers evaluations of scaffold biomaterials developed for enhancing the repair of musculoskeletal tissues. These bioimaging techniques include micro-CT, nano-CT, pQCT/QCT, MRI, and ultrasound, which provide not only 2-D and 3-D images of the related organs or tissues, but also quantifications of the relevant parameters. The advance bioimaging technologies developed for the above applications are also extended by incorporating imaging contrast-enhancement materials. Thus, this book will provide a unique platform for multidisciplinary collaborations in education and joint R and D among various professions, including biomedical engineering, biomaterials, and basic and clinical medicine. (orig.)

  1. Serum testosterone measurement in men: evaluation of modern immunoassay technologies.

    Science.gov (United States)

    Goncharov, N; Katsya, G; Dobracheva, A; Nizhnik, A; Kolesnikova, G; Todua, T; Lunenfeld, B

    2005-01-01

    Accurate measurement of serum testosterone (T) is essential for proper diagnosis of androgen deficiency. There are now several modern assay technologies, including automated ones, for measurement of T. In this study, we compared analytical performance of five modern immunoassay technologies commonly used for measurement of total T: Vitros ECi (Ortho-Clinical Diagnostics; normal range (n.r.) 4.6-34 nmol/L); Architect (Abbott Laboratories; n.r. 9.7-34 nmol/L); Access (Beckman Coulter; n.r. 5.3-23 nmol/L); Delfia (Perkin-Elmer; n.r. 9.3-34 nmol/L); and manual EIA DRG kits (n.r. 8.3-42 nmol/L), with the classical RIA (3H-T), after extraction (n.r. 11-33 nmol/L), as a reference method. Total T was measured using all above-mentioned methods in serum samples from 100 male patients, aged 16-65 years. Mean T concentrations in these 100 serum samples assayed by all non-isotopic methods were statistically significantly higher than those obtained by RIA. Delfia showed the highest T levels (19.3 nmol/L versus 12.1 nmol/L by RIA) with a positive bias 60-100%. Almost similar results were obtained using Architect, with a positive bias 40-70%. The closest correlation in results was found between Vitros ECi and RIA (12.7 nmol/L versus 12.1 nmol/L). In the studied samples, the median of differences ranged from minimal (-0.4 nmol/L for Vitros ECi) to maximal (-7.25 nmol/L for Delfia). For all non-isotopic methods, with the exception of Vitros ECi, differences in subjects with low T level ( 10 nmol/L). All other methods showed different degrees of dissimilarities with the RIA, especially in the range of low testosterone concentrations, which is of importance in the clinical assessment of women and pubertal boys.

  2. Application of Replica Technique and SEM in Accuracy Measurement of Ceramic Crowns

    Science.gov (United States)

    Trifkovic, B.; Budak, I.; Todorovic, A.; Hodolic, J.; Puskar, T.; Jevremovic, D.; Vukelic, D.

    2012-01-01

    The paper presents a comparative study of the measuring values of the marginal gap related to the ceramic crowns made by dental CAD/CAM system using the replica technique and SEM. The study was conducted using three experimental groups, which consisted of ceramic crowns manufactured by the Cerec CAD/CAM system. The scanning procedure was carried out using three specialized dental 3D digitization systems from the Cerec family - two types of extraoral optical scanning systems and an intraoral optical scanner. Measurements of the marginal gap were carried out using the replica technique and SEM. The comparison of aggregate values of the marginal gap using the replica technique showed a statistically significant difference between the systems. The measured values of marginal gaps of ceramic crowns using the replica technique were significantly lower compared to those measured by SEM. The results indicate that the choice of technique for measuring the accuracy of ceramic crowns influences the final results of investigation.

  3. Comparative study of various techniques for environmental radon, thoron and progeny measurements.

    Science.gov (United States)

    Ramola, R C; Prasad, Mukesh; Rawat, Mukesh; Dangwal, Anoop; Gusain, G S; Mishra, Rosaline; Sahoo, S K; Tokonami, S

    2015-11-01

    Long-term average concentrations of radon, thoron and progeny were measured in normal and high background radiation areas in India using different techniques. Radon, thoron and progeny concentrations were measured using Raduet, Pin-Hole dosimeter, deposition-based CR-39 and deposition-based direct radon/thoron progeny sensor (DRPS/DTPS) detector system. All these techniques were used at a same time inside an individual dwelling. Radon concentration was recorded higher than thoron concentration in Garhwal Homes (NBRA) while thoron concentration was found relatively higher in the houses of Chhatarpur area (HBRA) in Odisha, India. The values measured with the CR-39 detector-based technique were found comparable with the values measured with the LR-115 detector-based technique. The comparisons of results using various techniques and their usefulness in radiation measurements are discussed in detail.

  4. Implementation of the geoethics principal to environmental technologies by Biogeosystem Technique

    Science.gov (United States)

    Batukaev, Abdulmalik; Kalinitchenko, Valery; Minkina, Tatiana; Mandzhieva, Saglara; Sushkova, Svetlana

    2017-04-01

    The uncertainty and degradation of biosphere is a result of outdated industrial technologies. The incorrect principals of the nature resources use paradigm are to be radically changed corresponding to principals of Geoethics. Technological dead-end is linked to Philosophy of Technology. The organic protection and imitation of natural patterns are till now the theoretical base of technology. The technological and social determinism are proposed as the "inevitable" for humankind. One is forced to believe that the only way for humanity is to agree that the outdated way of technical development is the only possibility for humankind to survive. But rough imitation as a method of outdated technological platform is fruitless now. Survival under practice of industrial technology platform now has become extremely dangerous. The challenge for humanity is to overcome the chain of environmental hazards of agronomy, irrigation, industry, and other human activities in biosphere, which awkwardly imitate the natural processes: plowing leads to degradation of soil and greenhouse gases emission; irrigation leads to excessive moistening and degradation of soil, landscape, greenhouse gases emission, loss of freshwater - the global deficit; waste utilization leads to greenhouse gases emission, loss of oxigen and other ecological hazards. The fundamentally new technologies are to be generates for development of biosphere, food and resources renewing. Aristotle told that technique can go beyond nature and implement "what nature can't bring to a finish." To overcome fundamental shortcomings of industrial technologies, incorrect land use we propose the Biogeosystem Technique (BGT*) for biosphere sustainability. The BGT* key point is transcendent approach (not imitating of the natural processes) - new technical solutions for biosphere - soil construction, the fluxes of energy, matter, and water control and biological productivity of terrestrial systems. Intra-soil milling which provides the

  5. 20th International Conference for Students and Young Scientists: Modern Techniques and Technologies (MTT'2014)

    Science.gov (United States)

    2014-10-01

    The active involvement of young researchers in scientific processes and the acquisition of scientific experience by gifted youth currently have a great value for the development of science. One of the research activities of National Research Tomsk Polytechnic University, aimed at the preparing and formation of the next generation of scientists, is the International Conference of Students and Young Scientists ''Modern Techniques and Technologies'', which was held in 2014 for the twentieth time. Great experience in the organization of scientific events has been acquired through years of carrying the conference. There are all the necessary resources for this: a team of organizers - employees of Tomsk Polytechnic University, premises provided with modern office equipment and equipment for demonstration, and leading scientists - professors of TPU, as well as the status of the university as a leading research university in Russia. This way the conference is able to attract world leading scientists for the collaboration. For the previous years the conference proved itself as a major scientific event at international level, which attracts more than 600 students and young scientists from Russia, CIS and other countries. The conference provides oral plenary and section reports. The conference is organized around lectures, where leading Russian and foreign scientists deliver plenary presentations to young audiences. An important indicator of this scientific event is the magnitude of the coverage of scientific fields: energy, heat and power, instrument making, engineering, systems and devices for medical purposes, electromechanics, material science, computer science and control in technical systems, nanotechnologies and nanomaterials, physical methods in science and technology, control and quality management, design and technology of artistic materials processing. The main issues considered by young researchers at the conference were related to the analysis of contemporary

  6. Some Recommended Protection Technologies for Cyber Crime Based on Social Engineering Techniques -- Phishing

    CERN Document Server

    Gharibi, Wajeb

    2012-01-01

    Phishing (password + fishing) is a form of cyber crime based on social engineering and site spoofing techniques. The name of 'phishing' is a conscious misspelling of the word 'fishing' and involves stealing confidential data from a user's computer and subsequently using the data to steal the user's money. In this paper, we study, discuss and propose the phishing attack stages and types, technologies for detection of phishing web pages, and conclude our paper with some important recommendations for preventing phishing for both consumer and company.

  7. Specimen processing during laparoscopic renal surgery: a review of techniques and technologies

    Directory of Open Access Journals (Sweden)

    Saleh Binsaleh

    2014-01-01

    Full Text Available Laparoscopic surgery has well-defined benefits for patients and has become accepted over time as a standard access strategy for the management of benign and malignant urologic diseases. Unlike in open surgery, the surgeon is often faced with the additional challenges of specimen retrieval and extraction at the end of laparoscopic extirpative procedures. This final step often requires significant laparoscopic skill to entrap and safely extract the laparoscopic specimens. Failure to apply safe exit steps at the end of a laparoscopic procedure may lead to significant morbidity. The aim of this review is to explore the different techniques and technologies available for laparoscopic kidney retrieval, entrapment and safe extraction.

  8. Technological review on endoscopic submucosal dissection: available equipment, recent developments and emerging techniques.

    Science.gov (United States)

    Mavrogenis, Georgios; Hochberger, Juergen; Deprez, Pierre; Shafazand, Morteza; Coumaros, Dimitri; Yamamoto, Katsumi

    2017-04-01

    Endoscopic submucosal dissection (ESD) is widely practiced in Japan and the Eastern World and is rapidly expanding in western countries for the management of early malignancies of the upper and lower gastrointestinal tube. In addition, novel therapeutic applications deriving from ESD have emerged including the treatment of achalasia, of submucosal tumors, of diverticula, of strictures and of reflux disease. An ESD procedure necessitates not only skills and specific training, but also familiarization with a vast spectrum of devices (endoscopes, high-frequency generators and their settings, endoknives, hoods, irrigation devices) and techniques (such as countertraction, artificial ulcer closure), that render the procedure faster, more efficient and safer. This technological article gives an overview on current and novel equipment for an ESD and associated techniques.

  9. Marginal adaptation and CAD-CAM technology: A systematic review of restorative material and fabrication techniques.

    Science.gov (United States)

    Papadiochou, Sofia; Pissiotis, Argirios L

    2017-09-27

    The comparative assessment of computer-aided design and computer-aided manufacturing (CAD-CAM) technology and other fabrication techniques pertaining to marginal adaptation should be documented. Limited evidence exists on the effect of restorative material on the performance of a CAD-CAM system relative to marginal adaptation. The purpose of this systematic review was to investigate whether the marginal adaptation of CAD-CAM single crowns, fixed dental prostheses, and implant-retained fixed dental prostheses or their infrastructures differs from that obtained by other fabrication techniques using a similar restorative material and whether it depends on the type of restorative material. An electronic search of English-language literature published between January 1, 2000, and June 30, 2016, was conducted of the Medline/PubMed database. Of the 55 included comparative studies, 28 compared CAD-CAM technology with conventional fabrication techniques, 12 contrasted CAD-CAM technology and copy milling, 4 compared CAD-CAM milling with direct metal laser sintering (DMLS), and 22 investigated the performance of a CAD-CAM system regarding marginal adaptation in restorations/infrastructures produced with different restorative materials. Most of the CAD-CAM restorations/infrastructures were within the clinically acceptable marginal discrepancy (MD) range. The performance of a CAD-CAM system relative to marginal adaptation is influenced by the restorative material. Compared with CAD-CAM, most of the heat-pressed lithium disilicate crowns displayed equal or smaller MD values. Slip-casting crowns exhibited similar or better marginal accuracy than those fabricated with CAD-CAM. Cobalt-chromium and titanium implant infrastructures produced using a CAD-CAM system elicited smaller MD values than zirconia. The majority of cobalt-chromium restorations/infrastructures produced by DMLS displayed better marginal accuracy than those fabricated with the casting technique. Compared with copy

  10. Measurement of Learning Process by Semantic Annotation Technique on Bloom's Taxonomy Vocabulary

    Science.gov (United States)

    Yanchinda, Jirawit; Yodmongkol, Pitipong; Chakpitak, Nopasit

    2016-01-01

    A lack of science and technology knowledge understanding of most rural people who had the highest education at elementary education level more than others level is unsuccessfully transferred appropriate technology knowledge for rural sustainable development. This study provides the measurement of the learning process by on Bloom's Taxonomy…

  11. Application of MEMS Microphone Array Technology to Airframe Noise Measurements

    Science.gov (United States)

    Humphreys, William M., Jr.; Shams, Qamar A.; Graves, Sharon S.; Sealey, Bradley S.; Bartram, Scott M.; Comeaux, Toby

    2005-01-01

    Current generation microphone directional array instrumentation is capable of extracting accurate noise source location and directivity data on a variety of aircraft components, resulting in significant gains in test productivity. However, with this gain in productivity has come the desire to install larger and more complex arrays in a variety of ground test facilities, creating new challenges for the designers of array systems. To overcome these challenges, a research study was initiated to identify and develop hardware and fabrication technologies which could be used to construct an array system exhibiting acceptable measurement performance but at much lower cost and with much simpler installation requirements. This paper describes an effort to fabricate a 128-sensor array using commercially available Micro-Electro-Mechanical System (MEMS) microphones. The MEMS array was used to acquire noise data for an isolated 26%-scale high-fidelity Boeing 777 landing gear in the Virginia Polytechnic Institute and State University Stability Tunnel across a range of Mach numbers. The overall performance of the array was excellent, and major noise sources were successfully identified from the measurements.

  12. Performance Measurements and Technology Demonstration of the VASIMR® VX-200

    Science.gov (United States)

    Longmier, B. W.; Bering, E. A.; Squire, J. P.; Glover, T. W.; Cassady, L. D.; Ilin, A. V.; Carter, M. D.; Olsen, C. S.; McCaskill, G. E.; Chang Díaz, F.

    2010-12-01

    Recent progress is discussed in the development of an advanced RF electric propulsion engine: the VAriable Specific Impulse Magnetoplasma Rocket (VASIMR®) VX-200, a 200 kW flight-technology prototype. This device is the only known industrial application of the physics of the aurora borealis. Results are presented from first stage only and first stage with booster stage experiments that were performed on the VX-200 using between 60 mg/s and 150 mg/s argon propellant. The plasma source is a helicon discharge that uses whistler mode waves near the lower hybrid frequency. The booster stage uses electromagnetic ion cyclotron wave absorption to accelerate the ions. Measurements of ion flux, ion energy, plasma density and potential gradients, and force density profiles taken in the exhaust plume of the VX-200 are made within a 150 cubic meter vacuum chamber and are presented in the context of individual stage and total engine performance. Measurements include detailed pitch angle scans of the accelerated ions and plasma parameter maps of the exhaust plume. An emphasis will be given to our ability to probe wave-particle interactions in the exhaust plume. We are now in a position to conduct more detailed auroral simulation studies and are actively seeking collaborators.

  13. Kalman filtering techniques for reducing variance of digital speckle displacement measurement noise

    Institute of Scientific and Technical Information of China (English)

    Donghui Li; Li Guo

    2006-01-01

    @@ Target dynamics are assumed to be known in measuring digital speckle displacement. Use is made of a simple measurement equation, where measurement noise represents the effect of disturbances introduced in measurement process. From these assumptions, Kalman filter can be designed to reduce variance of measurement noise. An optical and analysis system was set up, by which object motion with constant displacement and constant velocity is experimented with to verify validity of Kalman filtering techniques for reduction of measurement noise variance.

  14. Limitations caused by distortion in room impulse response measurements by swept sine technique

    DEFF Research Database (Denmark)

    Stojic, Branko; Ciric, Dejan; Markovic, Milos

    2011-01-01

    of a measured response can be limited in a similar way as in maximum length sequence technique, although the saturation level (maximum dynamic range) is higher for swept sine technique. Thus, swept sine technique is also vulnerable to a certain extent to distortion that limits the quality of measured impulse......The significance of a room impulse response implies the requirement that its measurement should have a high level of accuracy in certain applications. One of the common problems in a measurement process is nonlinearity leading to the distortion of a room impulse response. Limitations caused...... by the distortion in room impulse response measurements by swept sine technique are analyzed here by the simulations and measurements. For the investigation, both linear and exponential swept sines are used as an excitation signal. In the simulations, this signal is modified by the nonlinearity model in the time...

  15. Measurement of precision oscillator phase noise using the two-oscillator coherent down-conversion technique

    Science.gov (United States)

    Pagnanelli, Christopher J.; Cashin, William F.

    1992-01-01

    The characterization of precision frequency standard phase noise and spurious outputs is addressed, using the two-oscillator coherent downconversion technique. Focus is on techniques for making accurate measurements of phase noise and spurious outputs within 100 KHz of a carrier. Significant sources of measurement error related to hardware design problems and inadequate measurement procedures are discussed: measurement errors resulting from system noise sources, phase-locked loop effects, and system bandwidth limitations. In addition, methods and design considerations for minimizing the effects of such errors are presented. Analytic discussions and results are supplemented with actual test data and measurements made using measurement hardware developed at the Ball Corporation, Efratom Division.

  16. Measuring and Assessing Application-Specific Technology Readiness

    Directory of Open Access Journals (Sweden)

    Antonino Ardilio

    2015-11-01

    Full Text Available Technology readiness is a crucial issue for decision-makers in technology-driven enterprises, determining whether the technology will or won’t be adopted for use in products or as a process technology. We know that, in some cases, lower technology readiness will be accepted by the users; these could be end-users, but, more often, it will be used in companies. The impact of a too early or too late adopted technology can be huge for companies and can even threaten market position or the existence of the company itself. Research institutes and technology developers, in particular application-oriented research organizations, might be also interested in which parameters or technology attributes should be improved or extended, according to the addressed application field, so that the technology fulfils the market-requested functions and a fast diffusion in the market can be achieved. Existing technology readiness models cover the various usages of the technology. In many cases, they assess the technology’s use in across different industries and application fields. However, the requirements in many fields are mostly different and very specific; thus, evaluation at such a high level can’t conclude whether the technology should be considered and adopted in the applications involved. This paper introduces an approach on how to determine and map the application-specific readiness of technology by decomposing both the application and the technology into its requested functions, as well as dynamically mapping the individual technology performance criteria. The applicability of this model will be demonstrated and discussed by a use case in the area of OLED-technology.

  17. ACCENT-BIAFLUX workshop 2005, trace gas and aerosol flux measurement and techniques. Abstract book

    Energy Technology Data Exchange (ETDEWEB)

    Werner, A.; Soerensen, L.L. (eds.)

    2005-04-01

    The woorkshop trace gas and aerosol flux measurement techniques in the second meeting within the Biosphere Atmosphere Exchange of Pollutions (BIAFLUX) group in the EU-network project Atmospheric Composition Change (ACCENT). The goal of the workshop is to obtain an overview of techniques for measurements of gas and aerosol fluxes and to gather the knowledge of uncertainties in flux measurements and calculations. The workshop is funded by ACCENT. The abstract book presents abstracts of 21 oral presentations and 26 poster presentations. (LN)

  18. Techniques and Technology to Revise Content Delivery and Model Critical Thinking in the Neuroscience Classroom.

    Science.gov (United States)

    Illig, Kurt R

    2015-01-01

    Undergraduate neuroscience courses typically involve highly interdisciplinary material, and it is often necessary to use class time to review how principles of chemistry, math and biology apply to neuroscience. Lecturing and Socratic discussion can work well to deliver information to students, but these techniques can lead students to feel more like spectators than participants in a class, and do not actively engage students in the critical analysis and application of experimental evidence. If one goal of undergraduate neuroscience education is to foster critical thinking skills, then the classroom should be a place where students and instructors can work together to develop them. Students learn how to think critically by directly engaging with course material, and by discussing evidence with their peers, but taking classroom time for these activities requires that an instructor find a way to provide course materials outside of class. Using technology as an on-demand provider of course materials can give instructors the freedom to restructure classroom time, allowing students to work together in small groups and to have discussions that foster critical thinking, and allowing the instructor to model these skills. In this paper, I provide a rationale for reducing the use of traditional lectures in favor of more student-centered activities, I present several methods that can be used to deliver course materials outside of class and discuss their use, and I provide a few examples of how these techniques and technologies can help improve learning outcomes.

  19. Science, technique, technology: passages between matter and knowledge in imperial Chinese agriculture.

    Science.gov (United States)

    Bray, Francesca

    2008-09-01

    Many historians today prefer to speak of knowledge and practice rather than science and technology. Here I argue for the value of reinstating the terms science, techniques and technology as tools for a more precise analysis of governmentality and the workings of power. My tactic is to use these three categories and their articulations to highlight flows between matter and ideas in the production and reproduction of knowledge. In any society, agriculture offers a wonderfully rich case of how ideas, material goods and social relations interweave. In China agronomy was a science of state, the basis of legitimate rule. I compare different genres of agronomic treatise to highlight what officials, landowners and peasants respectively contributed to, and expected from, this charged natural knowledge. I ask how new forms of textual and graphic inscription for encoding agronomic knowledge facilitated its dissemination and ask how successful this knowledge proved when rematerialized and tested as concrete artefacts or techniques. I highlight forms of innovation in response to crisis, and outline the overlapping interpretative frameworks within which the material applications of Chinese agricultural science confirmed and extended its truth across space and time.

  20. Managing the Classroom with Technology. On Progress Reports and Online Communications, and How To Manage the Two Different Communication Techniques.

    Science.gov (United States)

    Kasprowicz, Tim

    2002-01-01

    Describes how one teacher bridged the communications gap among teachers, parents, and students through the use of technology in managing his classroom. Discusses progress reports and online communications and how to manage the two different communication techniques. (JOW)

  1. Challenges, Strategies and Techniques for International Training in Technology for Cultural Heritage Conservation

    Science.gov (United States)

    Eppich, R.; Almagro Vidal, A.

    2013-07-01

    , Jordan, Argentina, United Arab Emirates, United States of America and around 20 other countries. These strategies deal with establishing methodologies and guiding principles for the selection of technologies, highlighting successful illustrated examples, levelling uneven educational bases and gaining access to expertise. The authors have developed these strategies and techniques to appeal, engage and succeed with such diverse groups - to encourage the participants to cooperate on a common goal and overcome specific challenges while embracing the technology and thinking critically about its appropriate application for the conservation of cultural heritage in their home countries. Other strategies include setting norms that respect the various cultures and differing levels of technology education, offering voluntary sessions for more advanced and ambitious participants, finding and then adopting natural leaders as co-instructors and offering a mix of sessions including standard lectures combined with field and laboratory exercises and distance learning. This methodology and strategies have proven to be successful as the participants have provided positive evaluations months and/or years after the courses, implemented their own courses using the materials and methods and have established a strong, sustainable network related to this topic.

  2. The development of advanced instrumentation and control technology -The development of digital monitoring technique-

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Jong Sun; Lee, Byung Sun; Han, Sang Joon; Shin, Yong Chul; Kim, Yung Baek; Kim, Dong Hoon; Oh, Yang Kyoon; Suh, Yung; Choi, Chan Duk; Kang, Byung Hun; Hong, Hyung Pyo; Shin, Jee Tae; Moon, Kwon Kee; Lee, Soon Sung; Kim, Sung Hoh; Koo, In Soo; Kim, Dong Wan; Huh, Sub [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-07-01

    A study has been performed for the advanced DSP technology for digital nuclear I and C systems and its prototype, and for the monitoring and diagnosing techniques for the highly-pressurized components in NSSS. In the DSP part, the DSP requirements for NPPs have been induced for the performance of the DSP systems and the functional analysis for Reactor Coolant System (RCS) has been performed as the embodied target system. Total quantities of the I and C signals, signal types, and signal functions were also investigated in Ulchin NPP units 3 and 4. From these basis, the prototype facility was configured for performance validation and algorithm implementation. In order to develop the methods of DSP techniques and algorithms, the current signal validation methods have been studied and analyzed. In the analysis for the communication networks in NPP, the basic technique for the configuration of communication networks and the important considerations for applying to NPPs have been reviewed. Test and experimental facilities have been set up in order to carry out the required tests during research activities on the monitoring techniques for abnormal conditions. Studies were concentrated on methods how to acquire vibration signals from the mechanical structures and equipment including rotating machinery and reactor, and analyses for the characteristics of the signals. Fuzzy logic was evaluated as a good technique to improve the reliability of the monitoring and diagnosing algorithm through the application of the theory such as the automatic pattern recognition algorithm of the vibration spectrum, the alarm detection and diagnosis for collisions of loose parts. 71 figs, 32 tabs, 64 refs. (Author).

  3. Assessment of the sulfur hexafluoride (SF6) tracer technique for measuring enteric methane emissions from cattle.

    Science.gov (United States)

    McGinn, S M; Beauchemin, K A; Iwaasa, A D; McAllister, T A

    2006-01-01

    A commonly used method of measuring enteric methane (CH4) emissions from ruminants is the SF6 tracer technique that measures respired and eructated CH4. However, within the animal, a small proportion of CH4 is produced post-ruminally and some of this may escape through the rectum. The comparison of emissions using a chamber technique that measures all enteric CH4 losses, and the SF6 tracer technique, could give some insight into the magnitude of post-ruminal emission. The objective of our study was to assess the precision and accuracy of the SF6 tracer technique against a chamber technique for cattle fed a range of diets. Using a repeated-measures design, eight beef heifers were offered a high grain or high forage diet for ad libitum or restricted (65% of ad libitum) feed intake to vary the site of digestion within the gastrointestinal tract (n = 24). The SF6 tracer technique underestimated CH4 emissions on average by 4% relative to the chamber technique. This difference was not significant (P > 0.05) and suggests low post-ruminal CH4 emissions. There was a trend for greater accuracy and precision of the SF6 tracer technique when used with cattle fed a high forage diet at a restricted level of intake. The high forage diet corresponds to the conditions of cattle grazing pasture, suggesting the SF6 tracer technique is most reliable for the grazing system.

  4. A comparison of concentration measurement techniques for the estimation of the apparent mass diffusion coefficient

    Directory of Open Access Journals (Sweden)

    L.M. Pereira

    2001-09-01

    Full Text Available In this article we compare two different techniques to measure the concentration of saline solutions for the identification of the apparent mass diffusion coefficient in soils saturated with distilled water. They are the radiation measurement technique and the electrical conductivity measurement technique. These techniques are compared in terms of measured quantities, sensitivity coefficients with respect to unknown parameters and the determinant of the information matrix. The apparent mass diffusion coefficient is estimated by utilizing simulated measurements containing random errors. The Levenberg-Marquardt method of minimization of the least-squares norm is used as the parameter estimation procedure. The effects of the volume of saline solution injected into the column devised for the experiments on the accuracy of the estimated parameters are also addressed in this article.

  5. Technology Development for Radiation Dose Measurement and Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Hwan; Chang, S. Y.; Lee, T. Y. (and others)

    2007-06-15

    The correction factors essential for the operation of In-Vivo counting system were produced and implemented into a field operation for the improvement of accuracy in measurement of the radioactivity inside a human body. The BiDAS2007 code which calculate an internal dose was developed by upgrading the former code prepared in the previous stage of this project. The method of using the multibioassy data, the maximum likelihood function and the Bayesian statistics were established to an internal dose based on the measurement data of radioactivity, intakes and retention of radioactivity in a human body and it can improve the accuracy in estimation of the intakes of radioactivity and the committed effective dose equivalent. In order to solve the problem of low detection efficiency of the conventional Bonner Sphere (BS) to a high energy neutron, the extended BS's were manufactured and the technique for neutron field spectrometry was established. The fast neutron and gamma spectrometry system with a BC501A scintillation detector was also prepared. Several neutron fluence spectra at several nuclear facilities were measured and collected by using the extended BS. The spectrum weighted responses of some neutron monitoring instruments were also derived by using these spectra and the detector response functions. A high efficient TL material for the neutron personal dosimeter was developed. It solved the main problem of low thermal stability and high residual dose of the commercial TLDs and has the sensitivity to neutron and to gamma radiation with 40 and 10 times higher respectively than them.

  6. Introduction of measurement techniques in ultrasonic electronics: Basic principles and recent trends

    Science.gov (United States)

    Mizutani, Koichi; Wakatsuki, Naoto; Ebihara, Tadashi

    2016-07-01

    Measurement — the act of measuring physical properties that we perform — has the potential to contribute to the successful advancement of sciences and society. To open doors in physics and other sciences, various measurement methods and related applications have been developed, and ultrasound has remained a useful probe, power source, and interesting measurement object for the past two centuries. In this paper, we first summarize the basic principles of ultrasound from the viewpoint of measurement techniques for readers who just have started studying or are interested in the field of ultrasonic electronics. Moreover, we also introduce recent studies — ultrasonic properties of materials, measurement techniques, piezoelectric devices, nonlinear acoustics, biomedical ultrasound, and ocean acoustics — and their trends related to measurement techniques in ultrasonic electronics to provide some ideas for related applications.

  7. Measurement of the amplitude and phase transfer functions of an optical modulator using a heterodyne technique

    DEFF Research Database (Denmark)

    Romstad, Francis Pascal; Birkedal, Dan; Mørk, Jesper

    2001-01-01

    We present a new technique that measures the full amplitude and phase transfer curves of the modulator as a function of the applied bias, from which the small signal α-parameter can be calculated. The technique measures the amplitude and phase transfer functions simultaneously and directly......, compared to techniques where a time-consuming data analysis is necessary to calculate the a-parameter and an additional measurement is necessary to estimate the phase. Additionally, the chirp profile for all operation points can be calculated....

  8. Application of Ultrasonic Technique for Measurement of Instantaneous Burn Rate of Solid Propellants .

    Directory of Open Access Journals (Sweden)

    Desh Deepak

    1998-04-01

    Full Text Available The ultrasonic pulse-echo technique has been applied for the measurement of instantaneous burnrate of aluminised composite solid propellants. The tests have been carried out on end-burning 30 mmthick propellant specimens at nearly constant pressure of about 1.9 MPa. Necessary software forpost-test data processing and instantaneous burn rate computations have been developed. The burnrates measured by the ultrasonic technique have been compared with those obtained from ballisticevaluation motor tests on propellant from the same mix. An accuracy of about +- 1 per cent ininstantaneous burn rate measurements and reproducibility of results have been demonstrated byapplying ultrasonic technique.

  9. Study on measurement technique for sodium aerosols based on laser induced breakdown spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ohtaka, Masahiko; Hayashida, Hitoshi [Japan Nuclear Cycle Development Inst., Oarai, Ibaraki (Japan). Oarai Engineering Center

    2003-03-01

    Detection of small-scale sodium leak in its early stage is effective for enhancing fast reactor safety. Feasibility of the measuring technique for sodium aerosols based on LIBS was assessed. The technique is expected to enhance performance on high discrimination for the sodium aerosols with an equivalent detection limit of conventional small sodium leak detectors. Experiments using sodium aerosols were performed in order to design a measuring system and to study on some basic measuring performances. The results show the LIBS technique is feasible as a small sodium leak detector. (author)

  10. Transforming the Narrative of the History of Chinese Technology: East and West in Bertrand Gille’s Histoire des Techniques

    Directory of Open Access Journals (Sweden)

    Yao Dazhi

    2015-05-01

    Full Text Available In his magisterial The History of Techniques, the French historian of technology Bertrand Gille (1920–1980 constructs a Western-centric world history of technology based on a technical systems approach. In doing so, he is forced to deal with the tension between Western-centric approaches and the conventional narrative of the history of Chinese technology. In order to avoid internal contradictions within his world history framework, Gille reconfigures the historical narrative about ancient China’s great inventions, arguing against unidirectional technology transfer and introducing the alternative notions of technological concomitant evolution and technological exchange. While Gille integrates ancient China into the general technological development of the world, he treats China as a blocked technical system and as “the other” in the West’s technological self-perception.

  11. Clean Technologies in Agriculture—How to Prioritise Measures?

    Directory of Open Access Journals (Sweden)

    Deborah Scharfy

    2017-07-01

    Full Text Available As agriculture continues to be under pressure due to its negative environmental impacts, resource-efficiency and the use of clean technologies gain importance. Meanwhile, there is an abundance of technological solutions that help “clean” agriculture’s hotspots, either by reducing inputs, by producing renewable energy or by protecting ecosystems. Decisions about clean technologies remain difficult due to the variety of options, difficulties in cost-benefit calculations, and potential trade-offs in sustainability. We therefore addressed the issue of decision-making regarding clean technologies in agriculture. A multi-criteria decision analysis (MCDA was used to rank the most sustainable technologies. Evaluation of 17 selected clean technologies was based on literature information and expert opinion. Wireless sensor irrigation networks, frequency converters for vacuum pumps and stable air conditioning, PV electricity and drip irrigation were the five technologies with the highest sustainability scores, outperforming the 12 other clean technologies. When all sustainability dimensions and criteria were equally weighted, PV electricity was superseded by variable speed drive technology for irrigation in the top five. This paper shows that MCDAs are a useful method for choosing between sustainable clean technology options. By applying different weighting, the MCDA can reflect the priorities of the decision maker and provide customised results.

  12. Measuring the corrosion rate of steel in concrete – effect of measurement technique, polarisation time and current

    DEFF Research Database (Denmark)

    Nygaard, Peter Vagn; Geiker, Mette Rica

    2012-01-01

    Both on-site investigations and laboratory studies have shown that different corrosion rates are obtained when different commercially available corrosion rate instruments are used. The different electrochemical techniques and the measurement parameters used, i.e. polarisation current and time......, are in some studies considered the main reasons for the variations. This paper presents an experimental study on the quantitative effect of polarisation time and current on the measured polarisation resistance – and thus the corrosion current density – of passively and actively corroding steel. Two...... electrochemical techniques often used in instruments for on-site corrosion rate measurements are investigated. On passively corroding reinforcement the measured polarisation resistance was for both techniques found to be highly affected by the polarisation time and current and no plateaus at either short or long...

  13. Application of data fusion techniques and technologies for wearable health monitoring.

    Science.gov (United States)

    King, Rachel C; Villeneuve, Emma; White, Ruth J; Sherratt, R Simon; Holderbaum, William; Harwin, William S

    2017-02-22

    Technological advances in sensors and communications have enabled discrete integration into everyday objects, both in the home and about the person. Information gathered by monitoring physiological, behavioural, and social aspects of our lives, can be used to achieve a positive impact on quality of life, health, and well-being. Wearable sensors are at the cusp of becoming truly pervasive, and could be woven into the clothes and accessories that we wear such that they become ubiquitous and transparent. To interpret the complex multidimensional information provided by these sensors, data fusion techniques are employed to provide a meaningful representation of the sensor outputs. This paper is intended to provide a short overview of data fusion techniques and algorithms that can be used to interpret wearable sensor data in the context of health monitoring applications. The application of these techniques are then described in the context of healthcare including activity and ambulatory monitoring, gait analysis, fall detection, and biometric monitoring. A snap-shot of current commercially available sensors is also provided, focusing on their sensing capability, and a commentary on the gaps that need to be bridged to bring research to market.

  14. A Novel Power Reduction Technique for Dual-Threshold Domino Logic in Sub-65nm Technology

    Directory of Open Access Journals (Sweden)

    Tarun Kr. Gupta

    2013-03-01

    Full Text Available A novel technique for dual- threshold is proposed and examined with inputs and clock signals combinationin 65nm dual- threshold footerless domino circuit for reduced leakage current. In this technique a p-typeand an n-type leakage controlled transistor (LCTsare introduced between the pull-up and pull-downnetwork and the gate of one is controlled by the source of the other. A high-threshold transistor is used inthe input for reducing gate oxide leakage current which becomes dominant in nanometer technology.Simulations based on 65nm BISM4 model for proposeddomino circuits shows that CLIL (clock low andinput low and CHIH (clock high and input high state is ineffective for lowering leakage current. TheCLIH (clock low input high state is only effective to suppress the leakage at low and high temperatures forwide fan-in domino circuits but for AND gate CHIL (clock high input low state is preferred to reducetheleakage current. The proposed circuit technique forAND2, OR2, OR4 and OR8 circuits reduces the activepower consumption by 39.6% to 57.9% and by 32.4% to40.3% at low and high die temperaturesrespectively when compared to the standard dual-threshold voltage domino logic circuits.

  15. A Novel Power Reduction Technique for Dual-Threshold Domino Logic in Sub-65nm Technology

    Directory of Open Access Journals (Sweden)

    Tarun Kr. Gupta

    2013-02-01

    Full Text Available A novel technique for dual- threshold is proposed and examined with inputs and clock signals combinationin 65nm dual- threshold footerless domino circuit for reduced leakage current. In this technique a p-typeand an n-type leakage controlled transistor (LCTsare introduced between the pull-up and pull-downnetwork and the gate of one is controlled by the source of the other. A high-threshold transistor is used inthe input for reducing gate oxide leakage current which becomes dominant in nanometer technology.Simulations based on 65nm BISM4 model for proposeddomino circuits shows that CLIL (clock low andinput low and CHIH (clock high and input high state is ineffective for lowering leakage current. TheCLIH (clock low input high state is only effective to suppress the leakage at low and high temperatures forwide fan-in domino circuits but for AND gate CHIL (clock high input low state is preferred to reducetheleakage current. The proposed circuit technique forAND2, OR2, OR4 and OR8 circuits reduces the activepower consumption by 39.6% to 57.9% and by 32.4% to40.3% at low and high die temperaturesrespectively when compared to the standard dual-threshold voltage domino logic circuits.

  16. Heterogeneity of inelastic strain during creep of Carrara marble: Microscale strain measurement technique

    Science.gov (United States)

    Quintanilla-Terminel, Alejandra; Evans, Brian

    2016-08-01

    We combined the split cylinder technique with microfabrication technology to observe strain heterogeneities that were produced during high-pressure transient creep of Carrara marble. Samples were patterned with a custom-designed grid of markers spaced 10 µm apart and containing an embedded coordinate system. The microscale strain measurement (MSSM) technique described here allowed us to analyze the local strain distribution with unprecedented detail over large regions. The description of the strain field is a function of the area over which strain is being computed. The scale at which the strain field can be considered homogeneous can provide insight into the deformation processes taking place. At 400-500°C, when twinning production is prolific, we observe highly strained bands that span several grains. One possible cause for the multigrain bands is the need to relieve strain incompatibilities that result when twins impinge on neighboring grains. At 600-700°C, the strain fields are still quite heterogeneous, and local strain varies substantially within grains and near grain boundaries, but the multigrain slip bands are not present. Deformation is concentrated in much smaller areas within grains and along some grain boundaries. The disappearance of the multigrain slip bands occurs when the deformation conditions allow additional slip systems to be activated. At 600°C, when the total strain is varied from 0.11 to 0.36, the spatial scale of the heterogeneity does not vary, but there are increases in the standard deviation of the distribution of local strains normalized by the total strain; thus, we conclude that the microstructure does not achieve a steady state in this strain interval.

  17. Techniques for Down-Sampling a Measured Surface Height Map for Model Validation

    Science.gov (United States)

    Sidick, Erkin

    2012-01-01

    This software allows one to down-sample a measured surface map for model validation, not only without introducing any re-sampling errors, but also eliminating the existing measurement noise and measurement errors. The software tool of the current two new techniques can be used in all optical model validation processes involving large space optical surfaces

  18. A non-Gaussian distribution quantifies distances measured with fluorescence localization techniques

    DEFF Research Database (Denmark)

    Churchman, L.S.; Flyvbjerg, H.; Spudich, J.A.

    2006-01-01

    When single-molecule fluorescence localization techniques are pushed to their lower limits in attempts to measure ever-shorter distances, measurement errors become important to understand. Here we describe the non-Gaussian distribution of measured distances that is the key to proper interpretation...

  19. Measurement of Device Parameters Using Image Recovery Techniques in Large-Scale IC Devices

    Science.gov (United States)

    Scheick, Leif; Edmonds, Larry

    2004-01-01

    Devices that respond to radiation on a cell level will produce histograms showing the relative frequency of cell damage as a function of damage. The measured distribution is the convolution of distributions from radiation responses, measurement noise, and manufacturing parameters. A method of extracting device characteristics and parameters from measured distributions via mathematical and image subtraction techniques is described.

  20. Overview of Photogrammetric Measurement Techniques in Minimally Invasive Surgery Using Endoscopes

    Science.gov (United States)

    Conen, N.; Luhmann, T.

    2017-05-01

    This contribution provides an overview of various photogrammetric measurement techniques in minimally invasive surgery and presents a self-developed prototypical trinocular endoscope for reliable surface measurements. Most of the presented techniques focus on applications regarding laparoscopy, which mean endoscopic operations in the abdominal or pelvic cavities. Since endoscopic operations are very demanding to the surgeon, various assistant systems have been developed. Imaging systems may use photogrammetric techniques in order to perform 3D measurements during operation. The intra-operatively acquired 3D data may be used for analysis, model registration, guidance or documentation. Passive and active techniques have been miniaturised, integrated into endoscopes and investigated by several research groups. The main advantages and disadvantages of several active and passive techniques adapted to laparoscopy are described in this contribution. Additionally, a self-developed trinocular endoscope is described and evaluated.