WorldWideScience

Sample records for technology assessment volume

  1. Large Deployable Reflector (LDR) system concept and technology definition study. Volume 2: Technology assessment and technology development plan

    Science.gov (United States)

    Agnew, Donald L.; Jones, Peter A.

    1989-01-01

    A study was conducted to define reasonable and representative LDR system concepts for the purpose of defining a technology development program aimed at providing the requisite technological capability necessary to start LDR development by the end of 1991. This volume presents thirteen technology assessments and technology development plans, as well as an overview and summary of the LDR concepts. Twenty-two proposed augmentation projects are described (selected from more than 30 candidates). The five LDR technology areas most in need of supplementary support are: cryogenic cooling; astronaut assembly of the optically precise LDR in space; active segmented primary mirror; dynamic structural control; and primary mirror contamination control. Three broad, time-phased, five-year programs were synthesized from the 22 projects, scheduled, and funding requirements estimated.

  2. Slope excavation quality assessment and excavated volume calculation in hydraulic projects based on laser scanning technology

    Directory of Open Access Journals (Sweden)

    Chao Hu

    2015-04-01

    Full Text Available Slope excavation is one of the most crucial steps in the construction of a hydraulic project. Excavation project quality assessment and excavated volume calculation are critical in construction management. The positioning of excavation projects using traditional instruments is inefficient and may cause error. To improve the efficiency and precision of calculation and assessment, three-dimensional laser scanning technology was used for slope excavation quality assessment. An efficient data acquisition, processing, and management workflow was presented in this study. Based on the quality control indices, including the average gradient, slope toe elevation, and overbreak and underbreak, cross-sectional quality assessment and holistic quality assessment methods were proposed to assess the slope excavation quality with laser-scanned data. An algorithm was also presented to calculate the excavated volume with laser-scanned data. A field application and a laboratory experiment were carried out to verify the feasibility of these methods for excavation quality assessment and excavated volume calculation. The results show that the quality assessment indices can be obtained rapidly and accurately with design parameters and scanned data, and the results of holistic quality assessment are consistent with those of cross-sectional quality assessment. In addition, the time consumption in excavation quality assessment with the laser scanning technology can be reduced by 70%–90%, as compared with the traditional method. The excavated volume calculated with the scanned data only slightly differs from measured data, demonstrating the applicability of the excavated volume calculation method presented in this study.

  3. Solar technology assessment project. Volume 6: Photovoltaic technology assessment

    Science.gov (United States)

    Backus, C. E.

    1981-04-01

    Industrial production of photovoltaic systems and volume of sales are reviewed. Low cost silicon production techniques are reviewed, including the Czochralski process, heat exchange method, edge defined film fed growth, dentritic web growth, and silicon on ceramic process. Semicrystalline silicon, amorphous silicon, and low cost poly-silicon are discussed as well as advanced materials and concentrator systems. Balance of system components beyond those needed to manufacture the solar panels are included. Nontechnical factors are assessed. The 1986 system cost goals are briefly reviewed.

  4. Immobilization of defense high-level waste: an assessment of technological strategies and potential regulatory goals. Volume I

    International Nuclear Information System (INIS)

    1979-06-01

    An investigation was made of the high-level radioactive waste immobilization technology programs in the U.S. and Europe, and of the associated regulatory programs and waste management perspectives in the countries studied. Purpose was to assess the ability of those programs to satisfy DOE waste management needs and U.S. regulatory requirements. This volume includes: introduction, immobilization strategies in the context of waste isolation program needs, high-level waste management as an integrated system, regulatory goals, engineered-barrier characteristics, barrier technology, high-level waste disposal programs, analysis of HLW immobilization technology in the context of policy and regulatory requirements, and waste immobilization program option

  5. An Independent Scientific Assessment of Well Stimulation in California Volume I

    Energy Technology Data Exchange (ETDEWEB)

    Long, Jane C.S. [California Council on Science and Technology, Sacramento, CA (United States); Feinstein, Laura C. [California Council on Science and Technology, Sacramento, CA (United States); Birkholzer, Jens [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Jordan, Preston [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Houseworth, James [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Dobson, Patrick F. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Heberger, Matthew [Pacific Inst., Oakland, CA (United States); Gautier, Donald L. [Dr. Donald Dautier, LLC., Palo Alto, CA (United States)

    2015-01-01

    In 2013, the California Legislature passed Senate Bill 4 (SB 4), setting the framework for regulation of well stimulation technologies in California, including hydraulic fracturing. SB 4 also requires the California Natural Resources Agency to conduct an independent scientific study of well stimulation technologies in California to assess current and potential future practices, including the likelihood that well stimulation technologies could enable extensive new petroleum production in the state, evaluate the impacts of well stimulation technologies and the gaps in data that preclude this understanding, identify risks associated with current practices, and identify alternative practices which might limit these risks. The study is issued in three volumes. This document, Volume I, provides the factual basis describing well stimulation technologies, how and where operators deploy these technologies for oil and gas production in California, and where they might enable production in the future. Volume II discusses how well stimulation affects water, the atmosphere, seismic activity, wildlife and vegetation, traffic, light and noise levels; it will also explore human health hazards, and identify data gaps and alternative practices. Volume III presents case studies to assess environmental issues and qualitative

  6. An Independent Scientific Assessment of Well Stimulation in California Volume II

    Energy Technology Data Exchange (ETDEWEB)

    Long, Jane C.S. [California Council on Science and Technology, Sacramento, CA (United States); Feinstein, Laura C. [California Council on Science and Technology, Sacramento, CA (United States); Bachmann, Corinne E. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Birkholzer, Jens T. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Camarillo, Mary Kay [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Domen, Jeremy K. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Foxall, William [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Houseworth, James [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Jin, Ling [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Jordan, Preston D. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Maddalena, Randy L. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); McKone, Thomas E. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Millstein, Dev E. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Reagan, Matthew T. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sandelin, Whitney L. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Stringfellow, William T. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Varadharajan, Charuleka [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Cooley, Heather [Pacific Inst., Oakland, CA (United States); Donnelly, Kristina [Pacific Inst., Oakland, CA (United States); Heberger, Matthew G. [Pacific Inst., Oakland, CA (United States); Hays, Jake [PSE Healthy Energy, Berkeley, CA (United States); Shonkoff, Seth B.C. [PSE Healthy Energy, Berkeley, CA (United States); Brandt, Adam [Stanford Univ., CA (United States); Englander, Jacob G. [Stanford Univ., CA (United States); Hamdoun, Amro [Univ. of California of San Diego, La Jolla, CA (United States); Nicklisch, Sascha C.T. [Univ. of California of San Diego, La Jolla, CA (United States); Harrison, Robert J. [Univ. of California, San Francisco, CA (United States); Wettstein, Zachary S. [Univ. of California, San Francisco, CA (United States); Banbury, Jenner [California State Univ. Stanislaus, Turlock, CA (United States); Cypher, Brian L. [California State Univ. Stanislaus, Turlock, CA (United States); Phillips, Scott E. [California State Univ. Stanislaus, Turlock, CA (United States)

    2015-07-01

    This study is issued in three volumes. Volume I, issued in January 2015, describes how well stimulation technologies work, how and where operators deploy these technologies for oil and gas production in California, and where they might enable production in the future. Volume II, the present volume, discusses how well stimulation could affect water, atmosphere, seismic activity, wildlife and vegetation, and human health. Volume II reviews available data, and identifies knowledge gaps and alternative practices that could avoid or mitigate these possible impacts. Volume III, also issued in July 2015, presents case studies that assess environmental issues and qualitative risks for specific geographic regions. A final Summary Report summarizes key findings, conclusions and recommendations of all three volumes.

  7. An Independent Scientific Assessment of Well Stimulation in California Volume III

    Energy Technology Data Exchange (ETDEWEB)

    Long, Jane C.S. [California Council on Science and Technology, Sacramento, CA (United States); Feinstein, Laura C. [California Council on Science and Technology, Sacramento, CA (United States); Birkholzer, Jens [California Council on Science and Technology, Sacramento, CA (United States); Foxall, William [California Council on Science and Technology, Sacramento, CA (United States); Houseworth, James [California Council on Science and Technology, Sacramento, CA (United States); Jordan, Preston [California Council on Science and Technology, Sacramento, CA (United States); Lindsey, Nathaniel [California Council on Science and Technology, Sacramento, CA (United States); Maddalena, Randy [California Council on Science and Technology, Sacramento, CA (United States); McKone, Thomas [California Council on Science and Technology, Sacramento, CA (United States); Stringfellow, William [California Council on Science and Technology, Sacramento, CA (United States); Ulrich, Craig [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Heberger, Matthew [Pacific Inst., Oakland, CA (United States); Shonkoff, Seth [PSE Healthy Energy, Berkeley, CA (United States); Brandt, Adam [Stanford Univ., CA (United States); Ferrar, Kyle [The FracTracker Alliance, Oakland, CA (United States); Gautier, Donald [DonGautier LLC., Palo Alto, CA (United States); Phillips, Scott [California State Univ. Stanislaus, Turlock, CA (United States); Greenfield, Ben [Univ. of California, Berkeley, CA (United States); Jerrett, Michael L.B. [Univ. of California, Los Angeles, CA (United States)

    2015-07-01

    This study is issued in three volumes. Volume I, issued in January 2015, describes how well stimulation technologies work, how and where operators deploy these technologies for oil and gas production in California, and where they might enable production in the future. Volume II, issued in July 2015, discusses how well stimulation could affect water, atmosphere, seismic activity, wildlife and vegetation, and human health. Volume II reviews available data, and identifies knowledge gaps and alternative practices that could avoid or mitigate these possible impacts. Volume III, this volume, presents case studies that assess environmental issues and qualitative risks for specific geographic regions. The Summary Report summarizes key findings, conclusions and recommendations of all three volumes.

  8. Oak Ridge K-25 Site Technology Logic Diagram. Volume 2, Technology Logic Diagrams

    Energy Technology Data Exchange (ETDEWEB)

    Fellows, R.L. [ed.

    1993-02-26

    The Oak Ridge K-25 Technology Logic Diagram (TLD), a decision support tool for the K-25 Site, was developed to provide a planning document that relates envirorunental restoration and waste management problems at the Oak Ridge K-25 Site to potential technologies that can remediate these problems. The TLD technique identifies the research necessary to develop these technologies to a state that allows for technology transfer and application to waste management, remedial action, and decontamination and decommissioning activities. The TLD consists of four separate volumes-Vol. 1, Vol. 2, Vol. 3A, and Vol. 3B. Volume 1 provides introductory and overview information about the TLD. This volume, Volume 2, contains logic diagrams with an index. Volume 3 has been divided into two separate volumes to facilitate handling and use.

  9. Hybrid Vehicle Technology Constraints and Application Assessment Study : Volume 1. Summary.

    Science.gov (United States)

    1977-11-01

    This four-volume report presents analyses and assessments of both heat engine/battery- and heat engine/flywheel-powered hybrid vehicles to determine if they could contribute to near-term (1980-1990) reductions in transportation energy consumption und...

  10. Pollutant Assessments Group procedures manual: Volume 2, Technical procedures

    Energy Technology Data Exchange (ETDEWEB)

    1992-03-01

    This is volume 2 of the manuals that describes the technical procedures currently in use by the Pollution Assessments Group. This manual incorporates new developments in hazardous waste assessment technology and administrative policy. Descriptions of the equipment, procedures and operations of such things as radiation detection, soil sampling, radionuclide monitoring, and equipment decontamination are included in this manual. (MB)

  11. Oak Ridge K-25 Site Technology Logic Diagram. Volume 1, Technology evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Fellows, R.L. [ed.

    1993-02-26

    The Oak Ridge K-25 Technology Logic Diagram (TLD), a decision support tool for the K-25 Site, was developed to provide a planning document that relates environmental restoration and waste management problems at the Oak Ridge K-25 Site to potential technologies that can remediate these problems. The TLD technique identifies the research necessary to develop these technologies to a state that allows for technology transfer and application to waste management, remedial action, and decontamination and decommissioning activities. The TLD consists of four separate volumes-Vol. 1, Vol. 2, Vol. 3A, and Vol. 3B. This Volume, Volume 1 provides introductory and overview information about the TLD. Volume 2 contains logic diagrams. Volume 3 has been divided into two separate volumes to facilitate handling and use. This volume is divided into ten chapters. The first chapter is a brief introduction, and the second chapter details the technical approach of the TLD. These categories are the work activities necessary for successful decontamination and decommissioning, waste management, and remedial action of the K-25 Site. The categories are characterization, decontamination, dismantlement, robotics and automation, remedial action, and waste management. Materials disposition is addressed in Chap. 9. The final chapter contains regulatory compliance information concerning waste management, remedial action, and decontamination and decommissioning.

  12. An assessment of thermal destruction technologies for application to Department of Energy mixed wastes

    International Nuclear Information System (INIS)

    1991-08-01

    A study of known operational and emerging thermal treatment technologies was conducted for the Department of Energy's (DOE's) Office of Technology Development (OTD) through the Hazardous Waste Remedial Actions Program (HAZWRAP). This study addressed thermal treatment of mixed wastes (MWs), for which the most comprehensive set of waste has been divided into two volumes. Volume 1 contains the details and results of the technology assessments and comparisons between technologies. This volume (Volume 2) contains the comprehensive data collected on each technology, including descriptions, process and cost data, comments on advantages and deficiencies, types of waste treatable and by-products of these wastes, and reference information. 2 figs

  13. The impact of health technology assessment reports on decision making in Austria.

    Science.gov (United States)

    Zechmeister, Ingrid; Schumacher, Ines

    2012-01-01

    Health technology assessment (HTA) was established in Austria in the 1990s and, since then, it has gained considerable importance. In this study, we aim to analyze whether the HTA reports that have been produced at the Institute for Technology Assessment (ITA) and at the Ludwig Boltzmann Institute for HTA (LBI-HTA) have had an impact on decision making within the Austrian health care system. We selected all reports that were intended for supporting (i) reimbursement/investment or (ii) disinvestment decisions. Eleven full HTA reports and fifty-eight rapid assessments fulfilled the inclusion criteria. We used interview data and administrative data on volumes, tariffs and expenditure of products/services to analyze whether and how reports were in reality used in decision making and what the consequences for health care expenditure and resource distribution have been. Five full HTA reports and fifty-six rapid technology assessments were used for reimbursement decisions. Four full HTA reports and two rapid assessments were used for disinvestment decisions and resulted in reduced volumes and expenditure. Two full HTA reports showed no impact on decision making. Impact was most evident for hospital technologies. HTA has played some role in reducing volumes of over-supplied hospital technologies, resulting in reduced expenditure for several hospital providers. Additionally, it has been increasingly included in prospective planning and reimbursement decisions of late, indicating re-distribution of resources toward evidence-based technologies. However, further factors may have influenced the decisions, and the impact could be considerably increased by systematically incorporating HTA into the decision-making process in Austria.

  14. Technology Audit: Assessment of Innovative Portfolio

    Directory of Open Access Journals (Sweden)

    Kurushina Viktoria

    2016-01-01

    Full Text Available The article discusses the features of the technological audit performing in the companies of oil and gas sector of Russian economy. To measure the innovations quality level the scale was developed based on the Theory of Inventive Problem Solving and the theory of technological structures. Figures of the innovations quantity by levels, volume and quality of the innovative portfolio are offered for assessment the innovative portfolio quality. The method was tested on an example of oil and gas transporting enterprises. The results of the comparative analysis of innovative portfolio are shown.

  15. Y-12 Plant remedial action Technology Logic Diagram: Volume 3, Technology evaluation data sheets: Part A, Remedial action

    International Nuclear Information System (INIS)

    1994-09-01

    The Y-12 Plant Remedial Action Technology Logic Diagram (TLD) was developed to provide a decision-support tool that relates environmental restoration (ER) problems at the Y-12 Plant to potential technologies that can remediate these problems. The TLD identifies the research, development, demonstration, testing, and evaluation needed for sufficient development of these technologies to allow for technology transfer and application to remedial action (RA) activities. The TLD consists of three volumes. Volume 1 contains an overview of the TLD, an explanation of the program-specific responsibilities, a review of identified technologies, and the rankings of remedial technologies. Volume 2 contains the logic linkages among environmental management goals, environmental problems and the various technologies that have the potential to solve these problems. Volume 3 contains the TLD data sheets. This report is Part A of Volume 3 and contains the Remedial Action section

  16. Y-12 Plant remedial action Technology Logic Diagram: Volume 3, Technology evaluation data sheets: Part A, Remedial action

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-09-01

    The Y-12 Plant Remedial Action Technology Logic Diagram (TLD) was developed to provide a decision-support tool that relates environmental restoration (ER) problems at the Y-12 Plant to potential technologies that can remediate these problems. The TLD identifies the research, development, demonstration, testing, and evaluation needed for sufficient development of these technologies to allow for technology transfer and application to remedial action (RA) activities. The TLD consists of three volumes. Volume 1 contains an overview of the TLD, an explanation of the program-specific responsibilities, a review of identified technologies, and the rankings of remedial technologies. Volume 2 contains the logic linkages among environmental management goals, environmental problems and the various technologies that have the potential to solve these problems. Volume 3 contains the TLD data sheets. This report is Part A of Volume 3 and contains the Remedial Action section.

  17. Hybrid Vehicle Technology Constraints and Application Assessment Study : Volume 3. Sections 5 through 9.

    Science.gov (United States)

    1977-11-01

    This four-volume report presents analyses and assessments of both heat engine/battery- and heat engine/flywheel-powered hybrid vehicles to determine if they could contribute to near-term (1980-1990) reductions in transportation energy consumption und...

  18. Hybrid Vehicle Technology Constraints and Application Assessment Study : Volume 2. Sections 1 through 4.

    Science.gov (United States)

    1977-01-01

    This four-volume report presents analyses and assessments of both heat engine/battery- and heat engine/flywheel-powered hybrid vehicles to determine if they could contribute to near-term (1980-1990) reductions in transportation energy consumption und...

  19. Y-12 Plant remedial action Technology Logic Diagram: Volume 3, Technology evaluation data sheets: Part B, Characterization; robotics/automation

    International Nuclear Information System (INIS)

    1994-09-01

    The Y-12 Plant Remedial Action Technology Logic Diagram (TLD) was developed to provide a decision-support tool that relates environmental restoration (ER) problems at the Y-12 Plant to potential technologies that can remediate theses problems. The TLD identifies the research, development, demonstration, testing, and evaluation needed for sufficient development of these technologies to allow for technology transfer and application to remedial action (RA) activities. The TLD consists of three volumes. Volume 1 contains an overview of the TLD, an explanation of the program-specific responsibilities, a review of identified technologies, and the rankings of remedial technologies. Volume 2 contains the logic linkages among environmental management goals, environmental problems, and the various technologies that have the potential to solve these problems. Volume 3 contains the TLD data sheets. This report is Part B of Volume 3 and contains the Characterization and Robotics/Automation sections

  20. Technology and economic assessment of lactic acid production and uses

    Energy Technology Data Exchange (ETDEWEB)

    Datta, R.; Tsai, S.P.

    1996-03-01

    Lactic acid has been an intermediate-volume specialty chemical (world production {approximately}50,000 tons/yr) used in a wide range of food-processing and industrial applications. Potentially, it can become a very large-volume, commodity-chemical intermediate produced from carbohydrates for feedstocks of biodegradable polymers, oxygenated chemicals, environmentally friendly ``green`` solvents, and other intermediates. In the past, efficient and economical technologies for the recovery and purification of lactic acid from fermentation broths and its conversion to the chemical or polymer intermediates had been the key technology impediments and main process cost centers. Development and deployment of novel separations technologies, such as electrodialysis with bipolar membranes, extractive and catalytic distillations, and chemical conversion, can enable low-cost production with continuous processes in large-scale operations. The emerging technologies can use environmentally sound lactic acid processes to produce environmentally useful products, with attractive process economics. These technology advances and recent product and process commercialization strategies are reviewed and assessed.

  1. ASEAN--USAID Buildings Energy Conservation Project final report. Volume 2, Technology

    Energy Technology Data Exchange (ETDEWEB)

    Levine, M.D.; Busch, J.F. [eds.

    1992-06-01

    This volume reports on research in the area of energy conservation technology applied to commercial buildings in the Association of Southeast Asian Nations (ASEAN) region. Unlike Volume I of this series, this volume is a compilation of original technical papers prepared by different authors in the project. In this regard, this volume is much like a technical journal. The papers that follow report on research conducted by both US and ASEAN researchers. The authors representing Indonesia, Malaysia, Philippines, and Thailand, come from a range of positions in the energy arena, including government energy agencies, electric utilities, and universities. As such, they account for a wide range of perspectives on energy problems and the role that technology can play in solving them. This volume is about using energy more intelligently. In some cases, the effort is towards the use of more advanced technologies, such as low-emittance coatings on window glass, thermal energy storage, or cogeneration. In others, the emphasis is towards reclaiming traditional techniques for rendering energy services, but in new contexts such as lighting office buildings with natural light, or cooling buildings of all types with natural ventilation. Used in its broadest sense, the term ``technology`` encompasses all of the topics addressed in this volume. Along with the more customary associations of technology, such as advanced materials and equipment and the analysis of their performance, this volume treats design concepts and techniques, analysis of ``secondary`` impacts from applying technologies (i.e., unintended impacts, or impacts on parties not directly involved in the purchase and use of the technology), and the collection of primary data used for conducting technical analyses.

  2. Technology assessment for the anesthesiologist.

    Science.gov (United States)

    Abenstein, J P

    2006-12-01

    The expense associated with modern heath care in the United States is very high, in excess of 15% of the GDP, continues to grow and has become a significant public policy issue. New technologies, defined as all drugs, devices, procedures, and organizational systems, are major contributors to rising health care costs. The use of health technology assessment tools can assist those in leadership positions in making rational decisions as to which new technologies to adopt. The classical approach is to use data from prospective, randomized, clinical trials that compare the outcomes of those treated with the new technology and the accepted therapy. Using this information and detailed economic data, the cost-effectiveness ratio can be determined. The accepted metrics are either dollars per life year saved or dollars per quality-adjusted life year saved. If the new medical intervention costs less than $50,000 to 80,000 dollars per life year saved, it is considered to be cost-effective and worthy of adoption. This kind of analysis is complex and expensive. In addition, the required information is not always available, limiting the applicability of this approach. Finally, the economic analysis often includes down-stream expense and benefit not relevant from a medical center perspective. Another approach is to focus the analysis to what impacts the medical center. This includes determining whether the technology has received the necessary approvals and has been shown to be effective, to improve health outcomes, to be at least as effective as standard therapy, and to be achievable outside the investigative setting. A fiscal analysis also must be done to determine what will it cost to acquire and operate the technology, what are the anticipated patient volumes and payer mix, and what will be the down-stream consequences to the medical center. If the process concludes that the technology works, makes a positive difference to patient care, and is fiscally and operationally

  3. Technology assessment of future intercity passenger transportation systems. Volume 7: Study recommendations

    Science.gov (United States)

    1976-01-01

    Research and analysis tasks to alleviate negative impacts, to augment positive impacts, or to better understand the impacts produced by the potential introduction of the alternate transportation technologies are identified. The project team's recommendations on research and analysis efforts which have resulted from the technology assessment are provided. Many of the recommendations apply to the future supply of intercity passenger transportation services, categorized by mode. Other recommendations pertain to broad issues in intercity transportation--e.g., finance, regulation, traveler values--that will affect all modes.

  4. Oak Ridge K-25 Site Technology Logic Diagram. Volume 3, Technology evaluation data sheets; Part A, Characterization, decontamination, dismantlement

    Energy Technology Data Exchange (ETDEWEB)

    Fellows, R.L. [ed.

    1993-02-26

    The Oak Ridge K-25 Technology Logic Diagram (TLD), a decision support tool for the K-25 Site, was developed to provide a planning document that relates environmental restoration and waste management problems at the Oak Ridge K-25 Site to potential technologies that can remediate these problems. The TLD technique identifies the research necessary to develop these technologies to a state that allows for technology transfer and application to waste management, remedial action, and decontamination and decommissioning activities. The TLD consists of four separate volumes-Vol. 1, Vol. 2, Vol. 3A, and Vol. 3B. Volume 1 provides introductory and overview information about the TLD. Volume 2 contains logic diagrams. Volume 3 has been divided into two separate volumes to facilitate handling and use. This report is part A of Volume 3 concerning characterization, decontamination, and dismantlement.

  5. Characterization of alternative electric generation technologies for the SPS comparative assessment: volume 2, central-station technologies

    International Nuclear Information System (INIS)

    1980-08-01

    The SPS Concept Development and Evaluation Program includes a comparative assessment. An early first step in the assessment process is the selection and characterization of alternative technologies. This document describes the cost and performance (i.e., technical and environmental) characteristics of six central station energy alternatives: (1) conventional coal-fired powerplant; (2) conventional light water reactor (LWR); (3) combined cycle powerplant with low-Btu gasifiers; (4) liquid metal fast breeder reactor (LMFBR); (5) photovoltaic system without storage; and (6) fusion reactor

  6. Oak Ridge National Laboratory Technology Logic Diagram. Volume 3, Technology evaluation data sheets: Part B, Dismantlement, Remedial action

    Energy Technology Data Exchange (ETDEWEB)

    1993-09-01

    The Oak Ridge National Laboratory Technology Logic Diagram (TLD) was developed to provide a decision support tool that relates environmental restoration (ER) and waste management (WM) problems at Oak Ridge National Laboratory (ORNL) to potential technologies that can remediate these problems. The TLD identifies the research, development, demonstration testing, and evaluation needed to develop these technologies to a state that allows technology transfer and application to decontamination and decommissioning (D&D), remedial action (RA), and WM activities. The TLD consists of three fundamentally separate volumes: Vol. 1, Technology Evaluation; Vol. 2, Technology Logic Diagram and Vol. 3, Technology EvaLuation Data Sheets. Part A of Vols. 1 and 2 focuses on RA. Part B of Vols. 1 and 2 focuses on the D&D of contaminated facilities. Part C of Vols. 1 and 2 focuses on WM. Each part of Vol. 1 contains an overview of the TM, an explanation of the problems facing the volume-specific program, a review of identified technologies, and rankings of technologies applicable to the site. Volume 2 (Pts. A. B. and C) contains the logic linkages among EM goals, environmental problems, and the various technologies that have the potential to solve these problems. Volume 3 (Pts. A. B, and C) contains the TLD data sheets. This volume provides the technology evaluation data sheets (TEDS) for ER/WM activities (D&D, RA and WM) that are referenced by a TEDS code number in Vol. 2 of the TLD. Each of these sheets represents a single logic trace across the TLD. These sheets contain more detail than is given for the technologies in Vol. 2.

  7. Hybrid Vehicle Technology Constraints and Application Assessment Study : Volume 4. Sections 10, 11, and Appendix.

    Science.gov (United States)

    1977-01-01

    This four-volume report presents analyses and assessments of both heat engine/battery- and heat engine/flywheel-powered hybrid vehicles to determine if they could contribute to near-term (1980-1990) reductions in transportation energy consumption und...

  8. Fusion Technology 1996. Proceedings. Volume 1 and 2

    International Nuclear Information System (INIS)

    Varandas, C.; Serra, F.

    1997-01-01

    The objective of these proceedings was to provide a platform for the exchange of information on the design, construction and operation of fusion experiments. The technology which is being developed for the next step devices and fusion reactors was also covered. Sections in volume 1 concern (A) first wall, divertors and vacuum systems; (B) plasma heating and control; (C) plasma engineering and control; and (D) experimental systems. The sections in volume 2 deal with (E) magnet and related power supplies; (F) fuel cycle and tritium processing systems; (G) blanket technology/materials; (H) assembly, remote handling and waste management and storage; and (I) safety and environment, and reactor studies

  9. Health Monitoring System Technology Assessments: Cost Benefits Analysis

    Science.gov (United States)

    Kent, Renee M.; Murphy, Dennis A.

    2000-01-01

    The subject of sensor-based structural health monitoring is very diverse and encompasses a wide range of activities including initiatives and innovations involving the development of advanced sensor, signal processing, data analysis, and actuation and control technologies. In addition, it embraces the consideration of the availability of low-cost, high-quality contributing technologies, computational utilities, and hardware and software resources that enable the operational realization of robust health monitoring technologies. This report presents a detailed analysis of the cost benefit and other logistics and operational considerations associated with the implementation and utilization of sensor-based technologies for use in aerospace structure health monitoring. The scope of this volume is to assess the economic impact, from an end-user perspective, implementation health monitoring technologies on three structures. It specifically focuses on evaluating the impact on maintaining and supporting these structures with and without health monitoring capability.

  10. Oak Ridge National Laboratory Technology Logic Diagram. Volume 3, Technology evaluation data sheets: Part C, Robotics/automation, Waste management

    Energy Technology Data Exchange (ETDEWEB)

    1993-09-01

    The Oak Ridge National Laboratory Technology Logic Diagram (TLD) was developed to provide a decision support tool that relates environmental restoration (ER) and waste management (WM) problems at Oak Ridge National Laboratory (ORNL) to potential technologies that can remediate these problems. The TLD identifies the research, development, demonstration testing, and evaluation needed to develop these technologies to a state that allows technology transfer and application to decontamination and decommissioning (D&D), remedial action (RA), and WM activities. The TLD consists of three fundamentally separate volumes: Vol. 1, Technology Evaluation; Vol. 2, Technology Logic Diagram and Vol. 3, Technology EvaLuation Data Sheets. Part A of Vols. 1 and 2 focuses on RA. Part B of Vols. 1 and 2 focuses on the D&D of contaminated facilities. Part C of Vols. 1 and 2 focuses on WM. Each part of Vol. 1 contains an overview of the TM, an explanation of the problems facing the volume-specific program, a review of identified technologies, and rankings of technologies applicable to the site. Volume 2 (Pts. A. B. and C) contains the logic linkages among EM goals, environmental problems, and the various technologies that have the potential to solve these problems. Volume 3 (Pts. A. B, and C) contains the TLD data sheets. This volume provides the technology evaluation data sheets (TEDS) for ER/WM activities (D&D, RA and WM) that are referenced by a TEDS code number in Vol. 2 of the TLD. Each of these sheets represents a single logic trace across the TLD. These sheets contain more detail than is given for the technologies in Vol. 2.

  11. Oak Ridge National Laboratory Technology Logic Diagram. Volume 1, Technology Evaluation: Part B, Remedial Action

    Energy Technology Data Exchange (ETDEWEB)

    1993-09-01

    The Oak Ridge National Laboratory Technology Logic Diagram (TLD) was developed to provide a decision-support tool that relates environmental restoration (ER) and waste management (WM) problems at Oak Ridge National Laboratory (ORNL) to potential technologies that can remediate these problems. The TLD identifies the research, development, demonstration, testing, and evaluation needed to develop these technologies to a state that allows technology transfer and application to decontamination and decommissioning (D&D), remedial action (RA), and WM activities. The TLD consists of three fundamentally separate volumes: Vol. 1 (Technology Evaluation), Vol. 2 (Technology Logic Diagram), and Vol. 3 (Technology Evaluation Data Sheets). Part A of Vols. 1 and 2 focuses on D&D. Part B of Vols. 1 and 2 focuses on RA of contaminated facilities. Part C of Vols. 1 and 2 focuses on WM. Each part of Vol. 1 contains an overview of the TLD, an explanation of the program-specific responsibilities, a review of identified technologies, and the ranking os remedial technologies. Volume 2 (Pts. A, B, and C) contains the logic linkages among EM goals, environmental problems, and the various technologies that have the potential to solve these problems. Volume 3 (Pts. A, B, and C) contains the TLD data sheets. The focus of Vol. 1, Pt. B, is RA, and it has been divided into six chapters. The first chapter is an introduction, which defines problems specific to the ER Program for ORNL. Chapter 2 provides a general overview of the TLD. Chapters 3 through 5 are organized into necessary subelement categories: RA, characterization, and robotics and automation. The final chapter contains regulatory compliance information concerning RA.

  12. Oak Ridge National Laboratory Technology Logic Diagram. Volume 2, Technology Logic Diagram: Part B, Remedial Action

    Energy Technology Data Exchange (ETDEWEB)

    1993-09-01

    The Oak Ridge National Laboratory Technology Logic Diagram (TLD) was developed to provide a decision support tool that relates environmental restoration (ER) and waste management (WM) problems at Oak Ridge National Laboratory (ORNL) to potential technologies that can remediate these problems. The TLD identifies the research, development, demonstration, testing, and evaluation needed to develop these technologies to a state that allows technology transfer and application to decontamination and decommissioning (D&D), remedial action (RA), and WM activities. The TLD consists of three fundamentally separate volumes: Vol. 1 (Technology Evaluation), Vol. 2 (Technology Logic Diagram), and Vol. 3 (Technology Evaluation Data Sheets). Part A of Vols. 1. and 2 focuses on D&D. Part B of Vols. 1 and 2 focuses on the RA of contaminated facilities. Part C of Vols. 1 and 2 focuses on WM. Each part of Vol. 1 contains an overview of the TLD, an explanation of the program-specific responsibilities, a review of identified technologies, and the rankings of remedial technologies. Volume 2 (Pts. A, B, and C) contains the logic linkages among EM goals, environmental problems, and the various technologies that have the potential to solve these problems. Volume 3 (Pts. A, B, and C) contains the TLD data sheets. Remedial action is the focus of Vol. 2, Pt. B, which has been divided into the three necessary subelements of the RA: characterization, RA, and robotics and automation. Each of these sections address general ORNL problems, which are then broken down by problem area/constituents and linked to potential remedial technologies. The diagrams also contain summary information about a technology`s status, its science and technology needs, and its implementation needs.

  13. Oak Ridge K-25 Site Technology Logic Diagram. Volume 3, Technology evaluation data sheets; Part B, Remedial action, robotics/automation, waste management

    Energy Technology Data Exchange (ETDEWEB)

    Fellows, R.L. [ed.

    1993-02-26

    The Oak Ridge K-25 Technology Logic Diagram (TLD), a decision support tool for the K-25 Site, was developed to provide a planning document that relates environmental restoration (ER) and waste management (WN) problems at the Oak Ridge K-25 Site. The TLD technique identifies the research necessary to develop these technologies to a state that allows for technology transfer and application to waste management, remediation, decontamination, and decommissioning activities. The TLD consists of four separate volumes-Vol. 1, Vol. 2, Vol. 3A, and Vol. 3B. Volume 1 provides introductory and overview information about the TLD. Volume 2 contains logic diagrams. Volume 3 has been divided into two separate volumes to facilitate handling and use. This volume 3 B provides the Technology Evaluation Data Sheets (TEDS) for ER/WM activities (Remedial Action Robotics and Automation, Waste Management) that are referenced by a TEDS code number in Vol. 2 of the TLD. Each of these sheets represents a single logic trace across the TLD. These sheets contain more detail than each technology in Vol. 2. The TEDS are arranged alphanumerically by the TEDS code number in the upper right corner of each data sheet. Volume 3 can be used in two ways: (1) technologies that are identified from Vol. 2 can be referenced directly in Vol. 3 by using the TEDS codes, and (2) technologies and general technology areas (alternatives) can be located in the index in the front of this volume.

  14. Coal slurry combustion and technology. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    1983-01-01

    Volume II contains papers presented at the following sessions of the Coal Slurry Combustion and Technology Symposium: (1) bench-scale testing; (2) pilot testing; (3) combustion; and (4) rheology and characterization. Thirty-three papers have been processed for inclusion in the Energy Data Base. (ATT)

  15. Liquid Metal Engineering and Technology. Volume 1

    International Nuclear Information System (INIS)

    1988-01-01

    These proceedings of the fourth international conference on liquid metal engineering and technology volume 1, are devided into 3 sections bearing on: - Apparatus and components for liquid metal (29 papers) - Liquid metal leaks, fires and fumes (10 papers) - Cleaning, decontamination, waste disposal (14 papers) [fr

  16. Current status and future potential for advanced volume reduction technologies

    International Nuclear Information System (INIS)

    Rutland, L.; Naughton, M.D.; Papaiya, N.C.

    1984-01-01

    With escalating costs for disposal of low-level radioactive waste (LLW) from nuclear power plants, and the possibility of unavailability of disposal space, some nuclear power utilities responded by commiting to implementing advanced volume reduction (VR) systems. This paper presents recent experience to implement advanced volume reduction technologies; their performance and typical operating and capital costs. This experience in the light of current economic conditions may enable us to predict the direction that future advanced VR technology commitments is taking

  17. Assessment of left atrial volume and function

    DEFF Research Database (Denmark)

    Kühl, J Tobias; Lønborg, Jacob; Fuchs, Andreas

    2012-01-01

    dynamic LA volume changes. Conversely, cardiac magnetic resonance imaging (CMR) and multi-slice computed tomography (MSCT) appears more appropriate for such measures. We sought to determine the relationship between LA size assessed with TTE and LA size and function assessed with CMR and MSCT. Fifty......-four patients were examined 3 months post myocardial infarction with echocardiography, CMR and MSCT. Left atrial volumes and LA reservoir function were assessed by TTE. LA time-volume curves were determined and LA reservoir function (cyclic change and fractional change), passive emptying function (reservoir...... between CMR and MSCT, with a small to moderate bias in LA(max) (4.9 ± 10.4 ml), CC (3.1 ± 9.1 ml) and reservoir volume (3.4 ± 9.1 ml). TTE underestimates LA(max) with up to 32% compared with CMR and MSCT (P ...

  18. Industrial Sector Technology Use Model (ISTUM): industrial energy use in the United States, 1974-2000. Volume 4. Technology appendix. Final Report

    Energy Technology Data Exchange (ETDEWEB)

    1979-10-01

    Volume IV of the ISTUM documentation gives information on the individual technology specifications, but relates closely with Chapter II of Volume I. The emphasis in that chapter is on providing an overview of where each technology fits into the general-model logic. Volume IV presents the actual cost structure and specification of every technology modeled in ISTUM. The first chapter presents a general overview of the ISTUM technology data base. It includes an explanation of the data base printouts and how the separate-cost building blocks are combined to derive an aggregate-technology cost. The remaining chapters are devoted to documenting the specific-technology cost specifications. Technologies included are: conventional technologies (boiler and non-boiler conventional technologies); fossil-energy technologies (atmospheric fluidized bed combustion, low Btu coal and medium Btu coal gasification); cogeneration (steam, machine drive, and electrolytic service sectors); and solar and geothermal technologies (solar steam, solar space heat, and geothermal steam technologies), and conservation technologies.

  19. Y-12 Plant decontamination and decommissioning technology logic diagram for Building 9201-4. Volume 2: Technology logic diagram

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-09-01

    The Y-12 Plant Decontamination and Decommissioning Technology Logic Diagram for Building 9201-4 (TLD) was developed to provide a decision-support tool that relates decontamination and decommissioning (D and D) problems at Bldg. 9201-4 to potential technologies that can remediate these problems. This TLD identifies the research, development, demonstration, testing, and evaluation needed for sufficient development of these technologies to allow for technology transfer and application to D and D and waste management (WM) activities. It is essential that follow-on engineering studies be conducted to build on the output of this project. These studies will begin by selecting the most promising technologies identified in the TLD and by finding an optimum mix of technologies that will provide a socially acceptable balance between cost and risk. The TLD consists of three fundamentally separate volumes: Vol. 1 (Technology Evaluation), Vol. 2 (Technology Logic Diagram), and Vol. 3 (Technology Evaluation Data Sheets). Volume 2 contains the logic linkages among environmental management goals, environmental problems, and the various technologies that have the potential to solve these problems. Volume 2 has been divided into five sections: Characterization, Decontamination, Dismantlement, Robotics/Automation, and Waste Management. Each section contains logical breakdowns of the Y-12 D and D problems by subject area and identifies technologies that can be reasonably applied to each D and D challenge.

  20. Y-12 Plant decontamination and decommissioning technology logic diagram for Building 9201-4. Volume 2: Technology logic diagram

    International Nuclear Information System (INIS)

    1994-09-01

    The Y-12 Plant Decontamination and Decommissioning Technology Logic Diagram for Building 9201-4 (TLD) was developed to provide a decision-support tool that relates decontamination and decommissioning (D and D) problems at Bldg. 9201-4 to potential technologies that can remediate these problems. This TLD identifies the research, development, demonstration, testing, and evaluation needed for sufficient development of these technologies to allow for technology transfer and application to D and D and waste management (WM) activities. It is essential that follow-on engineering studies be conducted to build on the output of this project. These studies will begin by selecting the most promising technologies identified in the TLD and by finding an optimum mix of technologies that will provide a socially acceptable balance between cost and risk. The TLD consists of three fundamentally separate volumes: Vol. 1 (Technology Evaluation), Vol. 2 (Technology Logic Diagram), and Vol. 3 (Technology Evaluation Data Sheets). Volume 2 contains the logic linkages among environmental management goals, environmental problems, and the various technologies that have the potential to solve these problems. Volume 2 has been divided into five sections: Characterization, Decontamination, Dismantlement, Robotics/Automation, and Waste Management. Each section contains logical breakdowns of the Y-12 D and D problems by subject area and identifies technologies that can be reasonably applied to each D and D challenge

  1. Technology for Space Station Evolution. Volume 3: EVA/Manned Systems/Fluid Management System

    Science.gov (United States)

    1990-01-01

    NASA's Office of Aeronautics and Space Technology (OAST) conducted a workshop on technology for space station evolution 16-19 Jan. 1990 in Dallas, Texas. The purpose of this workshop was to collect and clarify Space Station Freedom technology requirements for evolution and to describe technologies that can potentially fill those requirements. These proceedings are organized into an Executive Summary and Overview and five volumes containing the Technology Discipline Presentations. Volume 3 consists of the technology discipline sections for Extravehicular Activity/Manned Systems and the Fluid Management System. For each technology discipline, there is a Level 3 subsystem description, along with the papers.

  2. Technology 2003: The Fourth National Technology Transfer Conference and Exposition, volume 2

    Science.gov (United States)

    Hackett, Michael (Compiler)

    1994-01-01

    Proceedings from symposia of the Technology 2003 Conference and Exposition, Dec. 7-9, 1993, Anaheim, CA, are presented. Volume 2 features papers on artificial intelligence, CAD&E, computer hardware, computer software, information management, photonics, robotics, test and measurement, video and imaging, and virtual reality/simulation.

  3. Assessing medical technologies in development; a new paradigm of medical technology assessment

    NARCIS (Netherlands)

    Hummel, J. Marjan; van Rossum, Wouter; Verkerke, Gijsbertus Jacob; Rakhorst, Gerhard

    2000-01-01

    Objective: Our study aims to provide a practical contribution to the field of medical technology assessment within a new paradigm. This paradigm indicates the need for more comprehensive technology assessments in the development stage of a new technology. - Method: We introduce a method, based on

  4. Assessing medical technologies in development - A new paradigm of medical technology assessment

    NARCIS (Netherlands)

    Hummel, MJM; van Rossum, W; Verkerke, GJ; Rakhorst, G

    2000-01-01

    Objective: Our study aims to provide a practical contribution to the field of medical technology assessment within a new paradigm. This paradigm indicates the need for more comprehensive technology assessments in the development stage of a new technology. Method: We introduce a method, based on

  5. Low-level radioactive waste from commercial nuclear reactors. Volume 2. Treatment, storage, disposal, and transportation technologies and constraints

    Energy Technology Data Exchange (ETDEWEB)

    Jolley, R.L.; Dole, L.R.; Godbee, H.W.; Kibbey, A.H.; Oyen, L.C.; Robinson, S.M.; Rodgers, B.R.; Tucker, R.F. Jr.

    1986-05-01

    The overall task of this program was to provide an assessment of currently available technology for treating commercial low-level radioactive waste (LLRW), to initiate development of a methodology for choosing one technology for a given application, and to identify research needed to improve current treatment techniques and decision methodology. The resulting report is issued in four volumes. Volume 2 discusses the definition, forms, and sources of LLRW; regulatory constraints affecting treatment, storage, transportation, and disposal; current technologies used for treatment, packaging, storage, transportation, and disposal; and the development of a matrix relating treatment technology to the LLRW stream as an aid for choosing methods for treating the waste. Detailed discussions are presented for most LLRW treatment methods, such as aqueous processes (e.g., filtration, ion exchange); dewatering (e.g., evaporation, centrifugation); sorting/segregation; mechanical treatment (e.g., shredding, baling, compaction); thermal processes (e.g., incineration, vitrification); solidification (e.g., cement, asphalt); and biological treatment.

  6. Low-level radioactive waste from commercial nuclear reactors. Volume 2. Treatment, storage, disposal, and transportation technologies and constraints

    International Nuclear Information System (INIS)

    Jolley, R.L.; Dole, L.R.; Godbee, H.W.; Kibbey, A.H.; Oyen, L.C.; Robinson, S.M.; Rodgers, B.R.; Tucker, R.F. Jr.

    1986-05-01

    The overall task of this program was to provide an assessment of currently available technology for treating commercial low-level radioactive waste (LLRW), to initiate development of a methodology for choosing one technology for a given application, and to identify research needed to improve current treatment techniques and decision methodology. The resulting report is issued in four volumes. Volume 2 discusses the definition, forms, and sources of LLRW; regulatory constraints affecting treatment, storage, transportation, and disposal; current technologies used for treatment, packaging, storage, transportation, and disposal; and the development of a matrix relating treatment technology to the LLRW stream as an aid for choosing methods for treating the waste. Detailed discussions are presented for most LLRW treatment methods, such as aqueous processes (e.g., filtration, ion exchange); dewatering (e.g., evaporation, centrifugation); sorting/segregation; mechanical treatment (e.g., shredding, baling, compaction); thermal processes (e.g., incineration, vitrification); solidification (e.g., cement, asphalt); and biological treatment

  7. Using Technology to Improve Student Learning. NCREL Viewpoints, Volume 12

    Science.gov (United States)

    Gahala, Jan, Ed.

    2004-01-01

    "Viewpoints" is a multimedia package containing two audio CDs and a short, informative booklet. This volume of "Viewpoints" focuses on how technology can help improve student learning. The audio CDs provide the voices, or viewpoints, of various leaders from the education field who work closely with technology issues. Their…

  8. Idaho National Engineering Laboratory Waste Area Groups 1-7 and 10 Technology Logic Diagram. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    O`Brien, M.C.; Meservey, R.H.; Little, M.; Ferguson, J.S.; Gilmore, M.C.

    1993-09-01

    The Idaho National Engineering Laboratory (INEL) Technology Logic Diagram (TLD) was developed to provide a decision support tool that relates Environmental Restoration (ER) and Waste Management (WM) problems at the INEL to potential technologies that can remediate these problems. The TLD identifies the research, development, demonstration, testing, and evaluation needed to develop these technologies to a state that allows technology transfer and application to an environmental restoration need. It is essential that follow-on engineering and system studies be conducted to build on the output of this project. These studies will begin by selecting the most promising technologies identified in this TLD and finding an optimum mix of technologies that will provide a socially acceptable balance between cost and risk to meet the site windows of opportunity. The TLD consists of three separate volumes: Volume I includes the purpose and scope of the TLD, a brief history of the INEL Waste Area Groups, and environmental problems they represent. A description of the TLD, definitions of terms, a description of the technology evaluation process, and a summary of each subelement, is presented. Volume II (this volume) describes the overall layout and development of the TLD in logic diagram format. This section addresses the environmental restoration of contaminated INEL sites. Specific INEL problem areas/contaminants are identified along with technology solutions, the status of the technologies, precise science and technology needs, and implementation requirements. Volume III provides the Technology Evaluation Data Sheets (TEDS) for Environmental Restoration and Waste Management (EM) activities that are referenced by a TEDS codenumber in Volume II. Each of these sheets represents a single logic trace across the TLD. These sheets contain more detail than provided for technologies in Volume II.

  9. Technology transfer package on seismic base isolation - Volume III

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-02-14

    This Technology Transfer Package provides some detailed information for the U.S. Department of Energy (DOE) and its contractors about seismic base isolation. Intended users of this three-volume package are DOE Design and Safety Engineers as well as DOE Facility Managers who are responsible for reducing the effects of natural phenomena hazards (NPH), specifically earthquakes, on their facilities. The package was developed as part of DOE's efforts to study and implement techniques for protecting lives and property from the effects of natural phenomena and to support the International Decade for Natural Disaster Reduction. Volume III contains supporting materials not included in Volumes I and II.

  10. Information technology resources assessment

    Energy Technology Data Exchange (ETDEWEB)

    Stevens, D.F. [ed.

    1992-01-01

    This year`s Information Technology Resources Assessment (ITRA) is something of a departure from traditional practice. Past assessments have concentrated on developments in fundamental technology, particularly with respect to hardware. They form an impressive chronicle of decreasing cycle times, increasing densities, decreasing costs (or, equivalently, increasing capacity and capability per dollar spent), and new system architectures, with a leavening of operating systems and languages. Past assessments have aimed -- and succeeded -- at putting information technology squarely in the spotlight; by contrast, in the first part of this assessment, we would like to move it to the background, and encourage the reader to reflect less on the continuing technological miracles of miniaturization in space and time and more on the second- and third-order implications of some possible workplace applications of these miracles. This Information Technology Resources Assessment is intended to provide a sense of technological direction for planners in projecting the hardware, software, and human resources necessary to support the diverse IT requirements of the various components of the DOE community. It is also intended to provide a sense of our new understanding of the place of IT in our organizations.

  11. Information technology resources assessment

    Energy Technology Data Exchange (ETDEWEB)

    Stevens, D.F. (ed.)

    1992-01-01

    This year's Information Technology Resources Assessment (ITRA) is something of a departure from traditional practice. Past assessments have concentrated on developments in fundamental technology, particularly with respect to hardware. They form an impressive chronicle of decreasing cycle times, increasing densities, decreasing costs (or, equivalently, increasing capacity and capability per dollar spent), and new system architectures, with a leavening of operating systems and languages. Past assessments have aimed -- and succeeded -- at putting information technology squarely in the spotlight; by contrast, in the first part of this assessment, we would like to move it to the background, and encourage the reader to reflect less on the continuing technological miracles of miniaturization in space and time and more on the second- and third-order implications of some possible workplace applications of these miracles. This Information Technology Resources Assessment is intended to provide a sense of technological direction for planners in projecting the hardware, software, and human resources necessary to support the diverse IT requirements of the various components of the DOE community. It is also intended to provide a sense of our new understanding of the place of IT in our organizations.

  12. Technology assessment of thermal treatment technologies using ORWARE

    International Nuclear Information System (INIS)

    Assefa, G.; Eriksson, O.; Frostell, B.

    2005-01-01

    A technology assessment of thermal treatment technologies for wastes was performed in the form of scenarios of chains of technologies. The Swedish assessment tool, ORWARE, was used for the assessment. The scenarios of chains of thermal technologies assessed were gasification with catalytic combustion, gasification with flame combustion, incineration and landfilling. The landfilling scenario was used as a reference for comparison. The technologies were assessed from ecological and economic points of view. The results are presented in terms of global warming potential, acidification potential, eutrophication potential, consumption of primary energy carriers and welfare costs. From the simulations, gasification followed by catalytic combustion with energy recovery in a combined cycle appeared to be the most competitive technology from an ecological point of view. On the other hand, this alternative was more expensive than incineration. A sensitivity analysis was done regarding electricity prices to show which technology wins at what value of the unit price of electricity (SEK/kW h). Within this study, it was possible to make a comparison both between a combined cycle and a Rankine cycle (a system pair) and at the same time between flame combustion and catalytic combustion (a technology pair). To use gasification just as a treatment technology is not more appealing than incineration, but the possibility of combining gasification with a combined cycle is attractive in terms of electricity production. This research was done in connection with an empirical R and D work on both gasification of waste and catalytic combustion of the gasified waste at the Division of Chemical Technology, Royal Institute of Technology (KTH), Sweden

  13. Information and Communication Technologies in Africa Volume 1 ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Volume 1 looks at the introduction, adoption, and utilization of ICTs at the community level. In various contexts – geographical, technological, socioeconomic, cultural, and institutional – the book explores the questions of community participation. It looks at how communities in sub-Saharan Africa have reacted to the changes ...

  14. Idaho National Engineering Laboratory Waste Area Groups 1-7 and 10 Technology Logic Diagram. Volume 3

    Energy Technology Data Exchange (ETDEWEB)

    O`Brien, M.C.; Meservey, R.H.; Little, M.; Ferguson, J.S.; Gilmore, M.C.

    1993-09-01

    The Idaho National Engineering Laboratory (INEL) Technology Logic Diagram (TLD) was developed to provide a decision support tool that relates Environmental Restoration (ER) and Waste Management (WM) problems at the INEL to potential technologies that can remediate these problems. The TLD identifies the research, development, demonstration, testing, and evaluation needed to develop these technologies to a state that allows technology transfer and application to an environmental restoration need. It is essential that follow-on engineering and system studies be conducted to build on the output of this project. These studies will begin by selecting the most promising technologies identified in this TLD and finding an optimum mix of technologies that will provide a socially acceptable balance between cost and risk to meet the site windows of opportunity. The TLD consists of three separate volumes: Volume I includes the purpose and scope of the TLD, a brief history of the INEL Waste Area Groups, and environmental problems they represent. A description of the TLD, definitions of terms, a description of the technology evaluation process, and a summary of each subelement, is presented. Volume II describes the overall layout and development of the TLD in logic diagram format. This section addresses the environmental restoration of contaminated INEL sites. Volume III (this volume) provides the Technology Evaluation Data Sheets (TEDS) for Environmental Restoration and Waste Management (EM) activities that are reference by a TEDS code number in Volume II. Each of these sheets represents a single logic trace across the TLD. These sheets contain more detail than provided for technologies in Volume II. Data sheets are arranged alphanumerically by the TEDS code number in the upper right corner of each sheet.

  15. Shredder and incinerator technology for volume reduction of commercial transuranic wastes

    International Nuclear Information System (INIS)

    Oma, K.H.

    1986-06-01

    Pacific Northwest Laboratory (PNL) is evaluating alternatives and developing technology for treatment of radioactive wastes generated during commercial nuclear activities. Transuranic wastes that require volume reduction include spent HEPA filters, sample and analytical cell waste, and general process trash. A review of current technologies for volume reduction of these wastes led to the selection and testing of several low-speed shredder systems and three candidate incineration processes. The incinerators tested were the electrically heated control-led-air, gas-heated controlled-air, and rotary kiln. Equipment tests were conducted using simulated commercial transuranic wastes to provide a data base for the comparison of the various technologies. The electrically driven, low-speed shredder process was selected as the preferred method for size reduction of the wastes prior to incineration. All three incinerators effectively reduced the waste volume. Based on a technical and economic evaluation on the incineration processes, the recommended system for the commercial waste application is the gas-heated controlled-air incinerator with a single stage of shredding for feed pretreatment

  16. Health technology assessment in Finland

    DEFF Research Database (Denmark)

    Mäkelä, Marjukka; Roine, Risto P

    2010-01-01

    Since the 1990s, health policy makers in Finland have been supportive of evidence-based medicine and approaches to implement its results. The Finnish Office for Health Technology Assessment (Finohta) has grown from a small start in 1995 to a medium-sized health technology assessment (HTA) agency,...... findings. The Managed Uptake of Medical Methods program links the hospital districts to agree on introduction of technologies. The Ohtanen database provides Finnish-language summaries of major assessments made in other countries.......Since the 1990s, health policy makers in Finland have been supportive of evidence-based medicine and approaches to implement its results. The Finnish Office for Health Technology Assessment (Finohta) has grown from a small start in 1995 to a medium-sized health technology assessment (HTA) agency......, with special responsibility in providing assessments to underpin national policies in screening. External evaluations enhanced the rapid growth. In the Finnish environment, decision making on health technologies is extremely decentralized, so Finohta has developed some practical tools for implementing HTA...

  17. Risk assessment research and technology assessment

    International Nuclear Information System (INIS)

    Albach, H.; Schade, D.; Sinn, H.

    1991-01-01

    The concepts and approaches for technology assessment, the targets and scientific principles, as well as recognizable deficits and recommendations concerning purposeful strategies for the promotion of this research field require a dialog between those concerned. Conception, deficits, and the necessary measures for risk assessment research and technology assessment were discussed as well as ethical aspects. The problematic nature of using organisms altered through genetic engineering in the open land, traffic and transport, site restoration, nuclear energy, and isotope applications were subjects particularly dealt with. (DG) [de

  18. Information Technology and Literacy Assessment.

    Science.gov (United States)

    Balajthy, Ernest

    2002-01-01

    Compares technology predictions from around 1989 with the technology of 2002. Discusses the place of computer-based assessment today, computer-scored testing, computer-administered formal assessment, Internet-based formal assessment, computerized adaptive tests, placement tests, informal assessment, electronic portfolios, information management,…

  19. Technology Performance Level Assessment Methodology.

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, Jesse D.; Bull, Diana L; Malins, Robert Joseph; Costello, Ronan Patrick; Aurelien Babarit; Kim Nielsen; Claudio Bittencourt Ferreira; Ben Kennedy; Kathryn Dykes; Jochem Weber

    2017-04-01

    The technology performance level (TPL) assessments can be applied at all technology development stages and associated technology readiness levels (TRLs). Even, and particularly, at low TRLs the TPL assessment is very effective as it, holistically, considers a wide range of WEC attributes that determine the techno-economic performance potential of the WEC farm when fully developed for commercial operation. The TPL assessment also highlights potential showstoppers at the earliest possible stage of the WEC technology development. Hence, the TPL assessment identifies the technology independent “performance requirements.” In order to achieve a successful solution, the entirety of the performance requirements within the TPL must be considered because, in the end, all the stakeholder needs must be achieved. The basis for performing a TPL assessment comes from the information provided in a dedicated format, the Technical Submission Form (TSF). The TSF requests information from the WEC developer that is required to answer the questions posed in the TPL assessment document.

  20. Decontamination technology assessment

    International Nuclear Information System (INIS)

    Allen, R.P.; Konzek, G.J.; Schneider, K.R.; Smith, R.I.

    1988-10-01

    This study identifies and technically assesses foreign decontamination and decommissioning (D and D) technology developments that may represent significant improvements over D and D technology currently available or under development in the United States. Technology need areas for nuclear power reactor decommissioning operations were identified and prioritized using the results of past light water reactor (LWR) decommissioning studies to quantitatively evaluate the potential for reducing cost and decommissioning worker radiation dose for each major decommissioning activity. Based on these identified needs, current foreign D and D technologies of potential interest to the US were identified through personal contacts and the collection and review of an extensive body of D and D literature. These technologies were then assessed qualitatively to evaluate their uniqueness, potential for a significant reduction in D and D costs and/or worker radiation dose, development status, and other factors affecting their value and applicability to US needs. 4 refs

  1. Dual-Use Space Technology Transfer Conference and Exhibition. Volume 2

    Science.gov (United States)

    Krishen, Kumar (Compiler)

    1994-01-01

    This is the second volume of papers presented at the Dual-Use Space Technology Transfer Conference and Exhibition held at the Johnson Space Center February 1-3, 1994. Possible technology transfers covered during the conference were in the areas of information access; innovative microwave and optical applications; materials and structures; marketing and barriers; intelligent systems; human factors and habitation; communications and data systems; business process and technology transfer; software engineering; biotechnology and advanced bioinstrumentation; communications signal processing and analysis; medical care; applications derived from control center data systems; human performance evaluation; technology transfer methods; mathematics, modeling, and simulation; propulsion; software analysis and decision tools; systems/processes in human support technology; networks, control centers, and distributed systems; power; rapid development; perception and vision technologies; integrated vehicle health management; automation technologies; advanced avionics; and robotics technologies.

  2. ASSESSMENT OF QUALITY OF INNOVATIVE TECHNOLOGIES

    Directory of Open Access Journals (Sweden)

    Larisa Alexejevna Ismagilova

    2016-12-01

    Full Text Available We consider the topical issue of implementation of innovative technologies in the aircraft engine building industry. In this industry, products with high reliability requirements are developed and mass-produced. These products combine the latest achievements of science and technology. To make a decision on implementation of innovative technologies, a comprehensive assessment is carried out. It affects the efficiency of the innovations realization. In connection with this, the assessment of quality of innovative technologies is a key aspect in the selection of technological processes for their implementation. Problems concerning assessment of the quality of new technologies and processes of production are considered in the suggested method with respect to new positions. The developed method of assessing the quality of innovative technologies stands out for formed system of the qualimetric characteristics ensuring the effectiveness, efficiency, adaptability of innovative technologies and processes. The feature of suggested system of assessment is that it is based on principles of matching and grouping of quality indicators of innovative technologies and the characteristics of technological processes. The indicators are assessed from the standpoint of feasibility, technologies competiveness and commercial demand of products. In this paper, we discuss the example of implementing the approach of assessing the quality of the innovative technology of high-tech products such as turbine aircraft engine.

  3. Decontamination technology assessment

    International Nuclear Information System (INIS)

    Allen, R.P.; Konzek, G.J.; Schneider, K.J.; Smith, R.I.

    1988-01-01

    This study was conducted by the Pacific Northwest Laboratory (PNL) for the U.S. Department of Energy (DOE) to identify and technically assess foreign decontamination and decommissioning (D and D) technology developments that may represent significant improvements over D and D technology currently available or under development in the United States. Technology need areas for nuclear power reactor decommissioning operations were identified and prioritized using the results of past light water rector (LWR) decommissioning studies to quantitatively evaluate the potential for reducing cost and decommissioning worker radiation dose for each major decommissioning activity. Based on these identified needs, current foreign D and D technologies of potential interest to the U.S. were identified through personal contacts and the collection and review of an extensive body of D and D literature. These technologies were then assessed qualitatively to evaluate their uniqueness, potential for a significant reduction in D and D costs and/or worker radiation dose, development status, and other factors affecting their value and applicability to U.S. needs

  4. Airborne radioactive emission control technology. Volume II

    International Nuclear Information System (INIS)

    Skoski, L.; Berlin, R.; Corby, D.; Clancy, J.; Hoopes, G.

    1980-03-01

    This report reviews the current and future control technology for airborne emissions from a wide variety of industries/facilities, including uranium mining and milling, other nuclear fuel cycle facilities, other NRC-licensed and DOE facilities, fossil fuel facilities, selected metal and non-metal extraction industries, and others. Where specific radioactivity control technology is lacking, a description of any existing control technology is given. Future control technology is assessed in terms of improvements to equipment performance and process alterations. A catalogue of investigated research on advanced control technologies is presented

  5. Airborne radioactive emission control technology. Volume III

    International Nuclear Information System (INIS)

    Skoski, L.; Berlin, R.; Corby, D.; Clancy, J.; Hoopes, G.

    1980-03-01

    This report reviews the current and future control technology for airborne emissions from a wide variety of industries/facilities, including uranium mining and milling, other nuclear fuel cycle facilities, other NRC-licensed and DOE facilities, fossil fuel facilities, selected metal and non-metal extraction industries, and others. Where specific radioactivity control technology is lacking, a description of any existing control technology is given. Future control technology is assessed in terms of improvements to equipment performance and process alterations. A catalogue of investigated research on advanced control technologies is presented

  6. Airborne radioactive emission control technology. Volume I

    International Nuclear Information System (INIS)

    Skoski, L.; Berlin, R.; Corby, D.; Clancy, J.; Hoopes, G.

    1980-03-01

    This report reviews the current and future control technology for airborne emissions from a wide variety of industries/facilities, includimg uranium mining and milling, other nuclear fuel cycle facilities, other NRC-licensed and DOE facilities, fossil fuel facilities, selected metal and non-metal extraction industries, and others. Where specific radioactivity control technology is lacking a description of any existing control technology is given. Future control technology is assessed in terms of improvements to equipment performance and process alterations. A catalogue of investigated research on advanced control technologies is presented

  7. Approaches to Assessing Technological Literacy

    Science.gov (United States)

    Pearson, Greg

    2006-01-01

    It is the conclusion of the Committee on Assessing Technological Literacy, a study panel appointed by the National Academy of Engineering and the National Research Council, that very little is known about what children or adults know, can do, and believe about technology. This is because the state of assessment related to technology--or, …

  8. Transuranic and Low-Level Boxed Waste Form Nondestructive Assay Technology Overview and Assessment

    International Nuclear Information System (INIS)

    Becker, G.; Connolly, M.; McIlwain, M.

    1999-01-01

    The Mixed Waste Focus Area (MWFA) identified the need to perform an assessment of the functionality and performance of existing nondestructive assay (NDA) techniques relative to the low-level and transuranic waste inventory packaged in large-volume box-type containers. The primary objectives of this assessment were to: (1) determine the capability of existing boxed waste form NDA technology to comply with applicable waste radiological characterization requirements, (2) determine deficiencies associated with existing boxed waste assay technology implementation strategies, and (3) recommend a path forward for future technology development activities, if required. Based on this assessment, it is recommended that a boxed waste NDA development and demonstration project that expands the existing boxed waste NDA capability to accommodate the indicated deficiency set be implemented. To ensure that technology will be commercially available in a timely fashion, it is recommended this development and demonstration project be directed to the private sector. It is further recommended that the box NDA technology be of an innovative design incorporating sufficient NDA modalities, e.g., passive neutron, gamma, etc., to address the majority of the boxed waste inventory. The overall design should be modular such that subsets of the overall NDA system can be combined in optimal configurations tailored to differing waste types

  9. Low-level radioactive waste from commercial nuclear reactors. Volume 1. Recommendations for technology developments with potential to significantly improve low-level radioactive waste management

    International Nuclear Information System (INIS)

    Rodgers, B.R.; Jolley, R.L.

    1986-02-01

    The overall task of this program was to provide an assessment of currently available technology for treating commercial low-level radioactive waste (LLRW), to initiate development of a methodology for choosing one technology for a given application, and to identify research needed to improve current treatment techniques and decision methodology. The resulting report is issued in four volumes. Volume 1 provides an executive summary and a general introduction to the four-volume set, in addition to recommendations for research and development (R and D) for low-level radioactive waste (LLRW) treatment. Generic, long-range, and/or high-risk programs identified and prioritized as needed R and D in the LLRW field include: (1) systems analysis to develop decision methodology; (2) alternative processes for dismantling, decontaminating, and decommissioning; (3) ion exchange; (4) incinerator technology; (5) disposal technology; (6) demonstration of advanced technologies; (7) technical assistance; (8) below regulatory concern materials; (9) mechanical treatment techniques; (10) monitoring and analysis procedures; (11) radical process improvements; (12) physical, chemical, thermal, and biological processes; (13) fundamental chemistry; (14) interim storage; (15) modeling; and (16) information transfer. The several areas are discussed in detail

  10. Ion exchange technology assessment report

    International Nuclear Information System (INIS)

    Duhn, E.F.

    1992-01-01

    In the execution of its charter, the SRS Ion Exchange Technology Assessment Team has determined that ion exchange (IX) technology has evolved to the point where it should now be considered as a viable alternative to the SRS reference ITP/LW/PH process. The ion exchange media available today offer the ability to design ion exchange processing systems tailored to the unique physical and chemical properties of SRS soluble HLW's. The technical assessment of IX technology and its applicability to the processing of SRS soluble HLW has demonstrated that IX is unquestionably a viable technology. A task team was chartered to evaluate the technology of ion exchange and its potential for replacing the present In-Tank Precipitation and proposed Late Wash processes to remove Cs, Sr, and Pu from soluble salt solutions at the Savannah River Site. This report documents the ion exchange technology assessment and conclusions of the task team

  11. US long distance fiber optic networks: Technology, evolution and advanced concepts. Volume 2: Fiber optic technology and long distance networks

    Science.gov (United States)

    1986-10-01

    The study projects until 2000 the evolution of long distance fiber optic networks in the U.S. Volume 1 is the Executive Summary. Volume 2 focuses on fiber optic components and systems that are directly related to the operation of long-haul networks. Optimistic, pessimistic and most likely scenarios of technology development are presented. The activities of national and regional companies implementing fiber long haul networks are also highlighted, along with an analysis of the market and regulatory forces affecting network evolution. Volume 3 presents advanced fiber optic network concept definitions. Inter-LATA traffic is quantified and forms the basis for the construction of 11-, 15-, 17-, and 23-node networks. Using the technology projections from Volume 2, a financial model identifies cost drivers and determines circuit mile costs between any two LATAs. A comparison of fiber optics with alternative transmission concludes the report.

  12. Technologies for adaptation. Perspectives and practical experiences; Climate change

    Energy Technology Data Exchange (ETDEWEB)

    Christiansen, Lars; Olhoff, A; Traerup, S

    2011-11-15

    The present report is the second volume of the UNEP Risoe Centre Technology Transfer Perspectives Series. The report is related to the global Technology Needs Assessment (TNA) project, financed by the Global Environment Facility (GEF) and implemented by UNEP Risoe Centre. The nine articles in this volume discuss issues like: a) the concepts and context of technologies for adaptation; b) assessments of adaptation technology needs; c) practical experiences from working with technologies for adaptation. (LN)

  13. Automotive Manufacturing Assessment System : Volume 1. Master Product Schedules.

    Science.gov (United States)

    1999-11-01

    Volume I is part of a four volume set documenting areas of research resulting from the development of the Automotive Manufacturing Assessment System (AMAS) for the DOT/Transportation Systems Center. AMAS was designed to assist in the evaluation of in...

  14. ASSESSMENT OF GALLIUM OXIDE TECHNOLOGY

    Science.gov (United States)

    2017-08-01

    AFRL-RY-WP-TR-2017-0167 ASSESSMENT OF GALLIUM OXIDE TECHNOLOGY Burhan Bayraktaroglu Devices for Sensing Branch Aerospace...TITLE AND SUBTITLE ASSESSMENT OF GALLIUM OXIDE TECHNOLOGY 5a. CONTRACT NUMBER In-house 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER N/A 6...report summarizes the current status of the Ga2O3 technology based on published results on theoretical electronic structure, materials growth, and

  15. Depleted Uranium Hexafluoride Management Program. The technology assessment report for the long-term management of depleted uranium hexafluoride. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Zoller, J.N.; Rosen, R.S.; Holliday, M.A. [and others

    1995-06-30

    With the publication of a Request for Recommendations and Advance Notice of Intent in the November 10, 1994 Federal Register, the Department of Energy initiated a program to assess alternative strategies for the long-term management or use of depleted uranium hexafluoride. This Request was made to help ensure that, by seeking as many recommendations as possible, Department management considers reasonable options in the long-range management strategy. The Depleted Uranium Hexafluoride Management Program consists of three major program elements: Engineering Analysis, Cost Analysis, and an Environmental Impact Statement. This Technology Assessment Report is the first part of the Engineering Analysis Project, and assesses recommendations from interested persons, industry, and Government agencies for potential uses for the depleted uranium hexafluoride stored at the gaseous diffusion plants in Paducah, Kentucky, and Portsmouth, Ohio, and at the Oak Ridge Reservation in Tennessee. Technologies that could facilitate the long-term management of this material are also assessed. The purpose of the Technology Assessment Report is to present the results of the evaluation of these recommendations. Department management will decide which recommendations will receive further study and evaluation. These Appendices contain the Federal Register Notice, comments on evaluation factors, independent technical reviewers resumes, independent technical reviewers manual, and technology information packages.

  16. Depleted Uranium Hexafluoride Management Program. The technology assessment report for the long-term management of depleted uranium hexafluoride. Volume 1

    International Nuclear Information System (INIS)

    Zoller, J.N.; Rosen, R.S.; Holliday, M.A.

    1995-01-01

    With the publication of a Request for Recommendations and Advance Notice of Intent in the November 10, 1994 Federal Register, the Department of Energy initiated a program to assess alternative strategies for the long-term management or use of depleted uranium hexafluoride. This Request was made to help ensure that, by seeking as many recommendations as possible, Department management considers reasonable options in the long-range management strategy. The Depleted Uranium Hexafluoride Management Program consists of three major program elements: Engineering Analysis, Cost Analysis, and an Environmental Impact Statement. This Technology Assessment Report is the first part of the Engineering Analysis Project, and assesses recommendations from interested persons, industry, and Government agencies for potential uses for the depleted uranium hexafluoride stored at the gaseous diffusion plants in Paducah, Kentucky, and Portsmouth, Ohio, and at the Oak Ridge Reservation in Tennessee. Technologies that could facilitate the long-term management of this material are also assessed. The purpose of the Technology Assessment Report is to present the results of the evaluation of these recommendations. Department management will decide which recommendations will receive further study and evaluation. These Appendices contain the Federal Register Notice, comments on evaluation factors, independent technical reviewers resumes, independent technical reviewers manual, and technology information packages

  17. Assessing for Technological Literacy

    Science.gov (United States)

    Engstrom, Daniel E.

    2004-01-01

    Designing standards-based assessment is a key component of a quality technology education program. For students to become technologically literate, it is important that the teacher understands how to measure student understandings and abilities in the study of technology. This article is written to help teachers and teacher educators recognize the…

  18. Industrial Sector Technology Use Model (ISTUM): industrial energy use in the United States, 1974-2000. Volume 1. Primary model documentation. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Bohn, Roger E.; Herod, J. Steven; Andrews, Gwen L.; Budzik, Philip M.; Eissenstat, Richard S.; Grossmann, John R.; Reiner, Gary M.; Roschke, Thomas E.; Shulman, Michael J.; Toppen, Timothy R.; Veno, William R.; Violette, Daniel M.; Smolinski, Michael D.; Habel, Deborah; Cook, Alvin E.

    1979-10-01

    ISTUM is designed to predict the commercial market penetration of various energy technologies in the industrial sector out to the year 2000. It is a refinement and further development of Market Oriented Program Planning Study task force in 1977. ISTUM assesses the comparative economic competitiveness of each technology and competes over 100 energy technologies - conventionals, fossil/energy, conservation, cogeneration, solar, and geothermal. A broad overview of the model, the solution of the model, and an in-depth discussion of strength and limitations of the model are provided in Volume I. (MCW)

  19. Assessment of liver volume with spiral computerized tomography scanning: predicting liver volume by age and height

    OpenAIRE

    Madhu Sharma; Abhishek Singh; Shewtank Goel; Setu Satani; Kavita Mudgil

    2016-01-01

    Background: Estimation of liver size has critical clinical implication. Precise knowledge of liver dimensions and volume is prerequisite for clinical assessment of liver disorders. Liver span as measured by palpation and USG is prone to inter-observer variability and poor repeatability. The aim was to assess the normal liver volume of healthy adults using spiral computed tomography scans and to observe its relationship with various body indices. Methods: In this prospective study, all the...

  20. Satellite Power Systems (SPS) concept definition study. Volume 6: SPS technology requirements and verification

    Science.gov (United States)

    Hanley, G.

    1978-01-01

    Volume 6 of the SPS Concept Definition Study is presented and also incorporates results of NASA/MSFC in-house effort. This volume includes a supporting research and technology summary. Other volumes of the final report that provide additional detail are as follows: (1) Executive Summary; (2) SPS System Requirements; (3) SPS Concept Evolution; (4) SPS Point Design Definition; (5) Transportation and Operations Analysis; and Volume 7, SPS Program Plan and Economic Analysis.

  1. Technology transfer package on seismic base isolation - Volume II

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-02-14

    This Technology Transfer Package provides some detailed information for the U.S. Department of Energy (DOE) and its contractors about seismic base isolation. Intended users of this three-volume package are DOE Design and Safety Engineers as well as DOE Facility Managers who are responsible for reducing the effects of natural phenomena hazards (NPH), specifically earthquakes, on their facilities. The package was developed as part of DOE's efforts to study and implement techniques for protecting lives and property from the effects of natural phenomena and to support the International Decade for Natural Disaster Reduction. Volume II contains the proceedings for the Short Course on Seismic Base Isolation held in Berkeley, California, August 10-14, 1992.

  2. Volume reduction technology development for solid wastes from the nuclear fuel cycle

    International Nuclear Information System (INIS)

    Oh, Won Zin; Lee, Kune Woo; Song, Kee Chan; Choi, Wang Kyu; Kim, Young Min

    1998-07-01

    A great deal of solid wastes, which have various physical, chemical, and radiological characteristics, are generated from the nuclear fuel cycle facility as well as radioactive gaseous and liquid wastes. The treatment of the large quantity of solid wastes from the nuclear fuel cycle have great technical, economical and social effects on the domestic policy decision on the nuclear fuel cycle, such as operation and maintenance of the facility, waste disposal, etc. Cement immobilization, super compaction, and electrochemical dissolution were selected as the volume reduction technologies for solid wastes, which will generated from the domestic nuclear fuel cycle facility in the future. And the assessment of annual arisings and the preliminary conceptual design of volume reduction processes were followed. Electrochemical decontamination of α-radionuclides from the spent fuel hulls were experimentally investigated, and showed the successful results. However, β/γ radioactivity did not reduce to the level below which hulls can be classified as the low-level radioactive waste and sent to the disposal site for the shallow land burial. The effects of the various process variables in the electrochemical decontamination were experimentally analysed on the process. (author). 32 refs., 32 tabs., 52 figs

  3. Environmental control implications of generating electric power from coal. Technology status report. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    None

    1976-12-01

    This is the first in a series of reports evaluating environmental control technologies applicable to the coal-to-electricity process. The technologies are described and evaluated from an engineering and cost perspective based upon the best available information obtained from utility experience and development work in progress. Environmental control regulations and the health effects of pollutants are also reviewed. Emphasis is placed primarily upon technologies that are now in use. For SO/sub 2/ control, these include the use of low sulfur coal, cleaned coal, or flue-gas desulfurization systems. Electrostatic precipitators and fabric filters used for the control of particulate matter are analyzed, and combustion modifications for NO/sub x/ control are described. In each area, advanced technologies still in the development stage are described briefly and evaluated on the basis of current knowledge. Fluidized-bed combustion (FBC) is a near-term technology that is discussed extensively in the report. The potential for control of SO/sub 2/ and NO/sub x/ emissions by use of FBC is analyzed, as are the resulting solid waste disposal problems, cost estimates, and its potential applicability to electric utility systems. Volume II presents the detailed technology analyses complete with reference citations. This same material is given in condensed form in Volume I without references. A brief executive summary is also given in Volume I.

  4. SUSTAINABILITY LOGISTICS BASING SCIENCE AND TECHNOLOGY OBJECTIVE DEMONSTRATION; SELECTED TECHNOLOGY ASSESSMENT

    Science.gov (United States)

    2018-03-22

    BASING SCIENCE AND TECHNOLOGY OBJECTIVE – DEMONSTRATION; SELECTED TECHNOLOGY ASSESSMENT by Gregg J. Gildea Paul D. Carpenter Benjamin J...Campbell William F. Harris* Michael A. McCluskey** and José A. Miletti*** *General Dynamics Information Technology Fairfax, VA 22030 **Maneuver...SCIENCE AND TECHNOLOGY OBJECTIVE – DEMONSTRATION; SELECTED TECHNOLOGY ASSESSMENT 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT

  5. Identifying and Assessing Life-Cycle-Related Critical Technology Elements (CTEs) for Technology Readiness Assessments (TRAs)

    National Research Council Canada - National Science Library

    Mandelbaum, Jay

    2006-01-01

    .... Because these technologies are not emphasized in the current Technology Readiness Assessment (TRA) process this document is intended to improve the focus on life-cycle-related technologies in TRAs...

  6. History of the international societies in health technology assessment: International Society for Technology Assessment in Health Care and Health Technology Assessment International.

    Science.gov (United States)

    Banta, David; Jonsson, Egon; Childs, Paul

    2009-07-01

    The International Society for Technology Assessment in Health Care (ISTAHC) was formed in 1985. It grew out of the increasing awareness of the international dimensions of health technology assessment (HTA) and the need for new communication methods at the international level. The main function of ISTAHC was to present an annual conference, which gradually grew in size, and also to generally improve in quality from to year. ISTAHC overextended itself financially early in the first decade of the 2000s and had to cease its existence. A new society, Health Technology Assessment international (HTAi), based on many of the same ideas and people, grew up beginning in the year 2003. The two societies have played a large role in making the field of HTA visible to people around the world and providing a forum for discussion on the methods and role of HTA.

  7. High-power, ultralow-mass solar arrays: FY-77 solar arrays technology readiness assessment report, volume 2

    Science.gov (United States)

    Costogue, E. N.; Young, L. E.; Brandhorst, H. W., Jr.

    1978-01-01

    Development efforts are reported in detail for: (1) a lightweight solar array system for solar electric propulsion; (2) a high efficiency thin silicon solar cell; (3) conceptual design of 200 W/kg solar arrays; (4) fluorocarbon encapsulation for silicon solar cell array; and (5) technology assessment of concentrator solar arrays.

  8. Clean coal technology project to Polk Power Station, Tampa Electric Company, Florida, Volume 1: Report

    International Nuclear Information System (INIS)

    1994-06-01

    Tampa Electric Company proposes to construct and operate a 1,150-MW power station in southwestern Polk County, Florida. The proposed Polk Power Station would require an EPA NPDES permit for a new source and would include a 260-MW IGCC unit as a DOE Clean Coal Technology demonstration project. This EIS document assesses the proposed project and alternatives with respect to environmental impacts. Mitigative measures are also evaluated for the preferred alternative. Included in this Volume I are the following: alternatives including Tampa Electric Companies proposed project (preferred alternative with DOE financial assistance); affected environment; environmental consequences of the alternatives

  9. Assessment of Uncertainty-Based Screening Volumes for NASA Robotic LEO and GEO Conjunction Risk Assessment

    Science.gov (United States)

    Narvet, Steven W.; Frigm, Ryan C.; Hejduk, Matthew D.

    2011-01-01

    Conjunction Assessment operations require screening assets against the space object catalog by placing a pre-determined spatial volume around each asset and predicting when another object will violate that volume. The selection of the screening volume used for each spacecraft is a trade-off between observing all conjunction events that may pose a potential risk to the primary spacecraft and the ability to analyze those predicted events. If the screening volumes are larger, then more conjunctions can be observed and therefore the probability of a missed detection of a high risk conjunction event is small; however, the amount of data which needs to be analyzed increases. This paper characterizes the sensitivity of screening volume size to capturing typical orbit uncertainties and the expected number of conjunction events observed. These sensitivities are quantified in the form of a trade space that allows for selection of appropriate screen-ing volumes to fit the desired concept of operations, system limitations, and tolerable analyst workloads. This analysis will specifically highlight the screening volume determination and selection process for use in the NASA Conjunction Assessment Risk Analysis process but will also provide a general framework for other Owner / Operators faced with similar decisions.

  10. Feasibility study on application of volume acid fracturing technology to tight gas carbonate reservoir development

    Directory of Open Access Journals (Sweden)

    Nianyin Li

    2015-09-01

    Full Text Available How to effectively develop tight-gas carbonate reservoir and achieve high recovery is always a problem for the oil and gas industry. To solve this problem, domestic petroleum engineers use the combination of the successful experiences of North American shale gas pools development by stimulated reservoir volume (SRV fracturing with the research achievements of Chinese tight gas development by acid fracturing to propose volume acid fracturing technology for fractured tight-gas carbonate reservoir, which has achieved a good stimulation effect in the pilot tests. To determine what reservoir conditions are suitable to carry out volume acid fracturing, this paper firstly introduces volume acid fracturing technology by giving the stimulation mechanism and technical ideas, and initially analyzes the feasibility by the comparison of reservoir characteristics of shale gas with tight-gas carbonate. Then, this paper analyzes the validity and limitation of the volume acid fracturing technology via the analyses of control conditions for volume acid fracturing in reservoir fracturing performance, natural fracture, horizontal principal stress difference, orientation of in-situ stress and natural fracture, and gives the solution for the limitation. The study results show that the volume acid fracturing process can be used to greatly improve the flow environment of tight-gas carbonate reservoir and increase production; the incremental or stimulation response is closely related with reservoir fracturing performance, the degree of development of natural fracture, the small intersection angle between hydraulic fracture and natural fracture, the large horizontal principal stress difference is easy to form a narrow fracture zone, and it is disadvantageous to create fracture network, but the degradable fiber diversion technology may largely weaken the disadvantage. The practices indicate that the application of volume acid fracturing process to the tight-gas carbonate

  11. Viability Assessment Volume 1

    International Nuclear Information System (INIS)

    1998-01-01

    Since May 1996, under its draft Civilian Radioactive Waste Management Program Plan (DOE 1996), DOE has been carrying out a 5-year program of work to support the decision in 2001 by the Secretary of Energy on whether or not to recommend the site to the President. Part of this program was to address major unresolved technical issues and to complete an assessment of the viability of the Yucca Mountain site by 1998. Affirming the DOE plans, Congress directed DOE in the 1997 Energy and Water Development Appropriations Act to provide a viability assessment of the Yucca Mountain site to Congress and the President. This Viability Assessment (VA) document is the DOE report to Congress and the President. They are expected to use the VA to make an informed decision about program direction and funding. Drawing on 15 years of scientific investigation and design work at Yucca Mountain, the VA summarizes a large technical basis of field investigations, laboratory tests, models, analyses, and engineering, described in cited references. The VA identifies the major uncertainties relevant to the technical defensibility of DOE analyses and designs, the DOE approach to managing these uncertainties, and the status of work toward the site recommendation and LA. The VA also identifies DOE plans for the remaining work, and the estimated costs of completing an LA and constructing and operating a repository. The attention to uncertainties is important because DOE must evaluate how the repository will perform during the next 10,000 years or longer. Uncertainties exist because of variability in the natural (geologic and hydrologic) systems at Yucca Mountain and because of imperfect scientific understanding of the natural processes that might affect the repository system. This is Volume 1 and it covers, Introduction and Site Characteristics, includes a high-level summary of the results of the VA and some additional background information. (The overview is bound separately.) Section 1 of Volume

  12. Technology transfer package on seismic base isolation - Volume I

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-02-14

    This Technology Transfer Package provides some detailed information for the U.S. Department of Energy (DOE) and its contractors about seismic base isolation. Intended users of this three-volume package are DOE Design and Safety Engineers as well as DOE Facility Managers who are responsible for reducing the effects of natural phenomena hazards (NPH), specifically earthquakes, on their facilities. The package was developed as part of DOE's efforts to study and implement techniques for protecting lives and property from the effects of natural phenomena and to support the International Decade for Natural Disaster Reduction. Volume I contains the proceedings of the Workshop on Seismic Base Isolation for Department of Energy Facilities held in Marina Del Rey, California, May 13-15, 1992.

  13. Validity and reliability of a novel 3D scanner for assessment of the shape and volume of amputees' residual limb models.

    Directory of Open Access Journals (Sweden)

    Elena Seminati

    Full Text Available Objective assessment methods to monitor residual limb volume following lower-limb amputation are required to enhance practitioner-led prosthetic fitting. Computer aided systems, including 3D scanners, present numerous advantages and the recent Artec Eva scanner, based on laser free technology, could potentially be an effective solution for monitoring residual limb volumes.The aim of this study was to assess the validity and reliability of the Artec Eva scanner (practical measurement against a high precision laser 3D scanner (criterion measurement for the determination of residual limb model shape and volume.Three observers completed three repeat assessments of ten residual limb models, using both the scanners. Validity of the Artec Eva scanner was assessed (mean percentage error <2% and Bland-Altman statistics were adopted to assess the agreement between the two scanners. Intra and inter-rater reliability (repeatability coefficient <5% of the Artec Eva scanner was calculated for measuring indices of residual limb model volume and shape (i.e. residual limb cross sectional areas and perimeters.Residual limb model volumes ranged from 885 to 4399 ml. Mean percentage error of the Artec Eva scanner (validity was 1.4% of the criterion volumes. Correlation coefficients between the Artec Eva and the Romer determined variables were higher than 0.9. Volume intra-rater and inter-rater reliability coefficients were 0.5% and 0.7%, respectively. Shape percentage maximal error was 2% at the distal end of the residual limb, with intra-rater reliability coefficients presenting the lowest errors (0.2%, both for cross sectional areas and perimeters of the residual limb models.The Artec Eva scanner is a valid and reliable method for assessing residual limb model shapes and volumes. While the method needs to be tested on human residual limbs and the results compared with the current system used in clinical practice, it has the potential to quantify shape and volume

  14. Establishment of Health Technology Assessment in Iran

    Directory of Open Access Journals (Sweden)

    Shila Doaee

    2012-06-01

    Full Text Available Objective: Health Technology Assessment (HTA aims at informing healthcare policymakers, managers and practitioners of the "clinical consequences, but also the economic, ethical, and other social implications of the diffusion and use of a specific procedure or technique on medical practice". So considering the policy-oriented nature of HTA that calls for a close integration into the functioning and governance of health systems the present study focuses on executive processes and function of the HTA office of Iran.Materials and methods: Data of this review study were collected through documented sources and observations from 2007 to 2010.Results: Health Technology Assessment began its activities as a secretariat in the Deputy of Health in 2007 and it continues as a Health Technology Assessment Office at the Management of Health Technology Assessment, Standardization, and Tariff at the Deputy of curative affairs of MOHME in the beginning of 2010.14 Technology of modern medical equipment and 8 pharmaceutical medicine are assessed, Now many of measures for HTA establishment  such as cooperation National Institute of Health Research (NIHR, Holding scientific committee meetings, Establishing  the  Master's degree of  health technology assessment ,Building capacities for health technology assessment through education in major universities of the country.Conclusion: pay attention to health technology assessment, selection and application of proper technologies in the frameworks of policy-making and managerial strategies and make efforts to develop it with the support of the governmental in Iran is necessary.

  15. Ultrasound automated volume calculation in reproduction and in pregnancy.

    Science.gov (United States)

    Ata, Baris; Tulandi, Togas

    2011-06-01

    To review studies assessing the application of ultrasound automated volume calculation in reproductive medicine. We performed a literature search using the keywords "SonoAVC, sonography-based automated volume calculation, automated ultrasound, 3D ultrasound, antral follicle, follicle volume, follicle monitoring, follicle tracking, in vitro fertilization, controlled ovarian hyperstimulation, embryo volume, embryonic volume, gestational sac, and fetal volume" and conducted the search in PubMed, Medline, EMBASE, and the Cochrane Database of Systematic Reviews. Reference lists of identified reports were manually searched for other relevant publications. Automated volume measurements are in very good agreement with actual volumes of the assessed structures or with other validated measurement methods. The technique seems to provide reliable and highly reproducible results under a variety of conditions. Automated measurements take less time than manual measurements. Ultrasound automated volume calculation is a promising new technology which is already used in daily practice especially for assisted reproduction. Improvements to the technology will undoubtedly render it more effective and increase its use. Copyright © 2011 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  16. Depleted Uranium Hexafluoride Management Program. The technology assessment report for the long-term management of depleted uranium hexafluoride. Volume 2

    International Nuclear Information System (INIS)

    Zoller, J.N.; Rosen, R.S.; Holliday, M.A.

    1995-01-01

    With the publication of a Request for Recommendations and Advance Notice of Intent in the November 10, 1994 Federal Register, the Department of Energy initiated a program to assess alternative strategies for the long-term management or use of depleted uranium hexafluoride. This Request was made to help ensure that, by seeking as many recommendations as possible, Department management considers reasonable options in the long-range management strategy. The Depleted Uranium Hexafluoride Management Program consists of three major program elements: Engineering Analysis, Cost Analysis, and an Environmental Impact Statement. This Technology Assessment Report is the first part of the Engineering Analysis Project, and assesses recommendations from interested persons, industry, and Government agencies for potential uses for the depleted uranium hexafluoride stored at the gaseous diffusion plants in Paducah, Kentucky, and Portsmouth, Ohio, and at the Oak Ridge Reservation in Tennessee. Technologies that could facilitate the long-term management of this material are also assessed. The purpose of the Technology Assessment Report is to present the results of the evaluation of these recommendations. Department management will decide which recommendations will receive further study and evaluation

  17. Depleted Uranium Hexafluoride Management Program. The technology assessment report for the long-term management of depleted uranium hexafluoride. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    Zoller, J.N.; Rosen, R.S.; Holliday, M.A. [and others

    1995-06-30

    With the publication of a Request for Recommendations and Advance Notice of Intent in the November 10, 1994 Federal Register, the Department of Energy initiated a program to assess alternative strategies for the long-term management or use of depleted uranium hexafluoride. This Request was made to help ensure that, by seeking as many recommendations as possible, Department management considers reasonable options in the long-range management strategy. The Depleted Uranium Hexafluoride Management Program consists of three major program elements: Engineering Analysis, Cost Analysis, and an Environmental Impact Statement. This Technology Assessment Report is the first part of the Engineering Analysis Project, and assesses recommendations from interested persons, industry, and Government agencies for potential uses for the depleted uranium hexafluoride stored at the gaseous diffusion plants in Paducah, Kentucky, and Portsmouth, Ohio, and at the Oak Ridge Reservation in Tennessee. Technologies that could facilitate the long-term management of this material are also assessed. The purpose of the Technology Assessment Report is to present the results of the evaluation of these recommendations. Department management will decide which recommendations will receive further study and evaluation.

  18. Superconducting Technology Assessment

    National Research Council Canada - National Science Library

    2005-01-01

    This Superconducting Technology Assessment (STA) has been conducted by the National Security Agency to address the fundamental question of a potential replacement for silicon complementary metal oxide semiconductor (CMOS...

  19. SU-F-207-06: CT-Based Assessment of Tumor Volume in Malignant Pleural Mesothelioma

    International Nuclear Information System (INIS)

    Qayyum, F; Armato, S; Straus, C; Husain, A; Vigneswaran, W; Kindler, H

    2015-01-01

    Purpose: To determine the potential utility of computed tomography (CT) scans in the assessment of physical tumor bulk in malignant pleural mesothelioma patients. Methods: Twenty-eight patients with malignant pleural mesothelioma were used for this study. A CT scan was acquired for each patient prior to surgical resection of the tumor (median time between scan and surgery: 27 days). After surgery, the ex-vivo tumor volume was measured by a pathologist using a water displacement method. Separately, a radiologist identified and outlined the tumor boundary on each CT section that demonstrated tumor. These outlines then were analyzed to determine the total volume of disease present, the number of sections with outlines, and the mean volume of disease per outlined section. Subsets of the initial patient cohort were defined based on these parameters, i.e. cases with at least 30 sections of disease with a mean disease volume of at least 3mL per section. For each subset, the R- squared correlation between CT-based tumor volume and physical ex-vivo tumor volume was calculated. Results: The full cohort of 28 patients yielded a modest correlation between CT-based tumor volume and the ex-vivo tumor volume with an R-squared value of 0.66. In general, as the mean tumor volume per section increased, the correlation of CT-based volume with the physical tumor volume improved substantially. For example, when cases with at least 40 CT sections presenting a mean of at least 2mL of disease per section were evaluated (n=20) the R-squared correlation increased to 0.79. Conclusion: While image-based volumetry for mesothelioma may not generally capture physical tumor volume as accurately as one might expect, there exists a set of conditions in which CT-based volume is highly correlated with the physical tumor volume. SGA receives royalties and licensing fees through the University of Chicago for computer-aided diagnosis technology

  20. SU-F-207-06: CT-Based Assessment of Tumor Volume in Malignant Pleural Mesothelioma

    Energy Technology Data Exchange (ETDEWEB)

    Qayyum, F; Armato, S; Straus, C; Husain, A; Vigneswaran, W; Kindler, H [The University of Chicago, Chicago, IL (United States)

    2015-06-15

    Purpose: To determine the potential utility of computed tomography (CT) scans in the assessment of physical tumor bulk in malignant pleural mesothelioma patients. Methods: Twenty-eight patients with malignant pleural mesothelioma were used for this study. A CT scan was acquired for each patient prior to surgical resection of the tumor (median time between scan and surgery: 27 days). After surgery, the ex-vivo tumor volume was measured by a pathologist using a water displacement method. Separately, a radiologist identified and outlined the tumor boundary on each CT section that demonstrated tumor. These outlines then were analyzed to determine the total volume of disease present, the number of sections with outlines, and the mean volume of disease per outlined section. Subsets of the initial patient cohort were defined based on these parameters, i.e. cases with at least 30 sections of disease with a mean disease volume of at least 3mL per section. For each subset, the R- squared correlation between CT-based tumor volume and physical ex-vivo tumor volume was calculated. Results: The full cohort of 28 patients yielded a modest correlation between CT-based tumor volume and the ex-vivo tumor volume with an R-squared value of 0.66. In general, as the mean tumor volume per section increased, the correlation of CT-based volume with the physical tumor volume improved substantially. For example, when cases with at least 40 CT sections presenting a mean of at least 2mL of disease per section were evaluated (n=20) the R-squared correlation increased to 0.79. Conclusion: While image-based volumetry for mesothelioma may not generally capture physical tumor volume as accurately as one might expect, there exists a set of conditions in which CT-based volume is highly correlated with the physical tumor volume. SGA receives royalties and licensing fees through the University of Chicago for computer-aided diagnosis technology.

  1. Probabilistic risk assessment, Volume I

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    This book contains 158 papers presented at the International Topical Meeting on Probabilistic Risk Assessment held by the American Nuclear Society (ANS) and the European Nuclear Society (ENS) in Port Chester, New York in 1981. The meeting was second in a series of three. The main focus of the meeting was on the safety of light water reactors. The papers discuss safety goals and risk assessment. Quantitative safety goals, risk assessment in non-nuclear technologies, and operational experience and data base are also covered. Included is an address by Dr. Chauncey Starr

  2. Technologies Assessing Limb Bradykinesia in Parkinson's Disease.

    Science.gov (United States)

    Hasan, Hasan; Athauda, Dilan S; Foltynie, Thomas; Noyce, Alastair J

    2017-01-01

    The MDS-UPDRS (Movement Disorders Society - Unified Parkinson's Disease Rating Scale) is the most widely used scale for rating impairment in PD. Subscores measuring bradykinesia have low reliability that can be subject to rater variability. Novel technological tools can be used to overcome such issues. To systematically explore and describe the available technologies for measuring limb bradykinesia in PD that were published between 2006 and 2016. A systematic literature search using PubMed (MEDLINE), IEEE Xplore, Web of Science, Scopus and Engineering Village (Compendex and Inspec) databases was performed to identify relevant technologies published until 18 October 2016. 47 technologies assessing bradykinesia in PD were identified, 17 of which offered home and clinic-based assessment whilst 30 provided clinic-based assessment only. Of the eligible studies, 7 were validated in a PD patient population only, whilst 40 were tested in both PD and healthy control groups. 19 of the 47 technologies assessed bradykinesia only, whereas 28 assessed other parkinsonian features as well. 33 technologies have been described in additional PD-related studies, whereas 14 are not known to have been tested beyond the pilot phase. Technology based tools offer advantages including objective motor assessment and home monitoring of symptoms, and can be used to assess response to intervention in clinical trials or routine care. This review provides an up-to-date repository and synthesis of the current literature regarding technology used for assessing limb bradykinesia in PD. The review also discusses the current trends with regards to technology and discusses future directions in development.

  3. 9th Pacific Basin Nuclear Conference. Nuclear energy, science and technology - Pacific partnership. Proceedings Volume 1

    International Nuclear Information System (INIS)

    1994-04-01

    The theme of the 9th Pacific Basin Nuclear conference held in Sydney from 1-6 May 1994, embraced the use of the atom in energy production and in science and technology. The focus was on selected topics of current and ongoing interest to countries around the Pacific Basin. The two-volume proceedings include both invited and contributed papers. They have been indexed separately. This document, Volume 1 covers the following topics: Pacific partnership; perspectives on nuclear energy, science and technology in Pacific Basin countries; nuclear energy and sustainable development; economics of the power reactors; new power reactor projects; power reactor technology; advanced reactors; radioisotope and radiation technology; biomedical applications

  4. Information Technology Resources Assessment

    Energy Technology Data Exchange (ETDEWEB)

    1993-04-01

    The Information Technology Resources Assessment (ITRA) is being published as a companion document to the Department of Energy (DOE) FY 1994--FY 1998 Information Resources Management Long-Range Plan. This document represents a collaborative effort between the Office of Information Resources Management and the Office of Energy Research that was undertaken to achieve, in part, the Technology Strategic Objective of IRM Vision 21. An integral part of this objective, technology forecasting provides an understanding of the information technology horizon and presents a perspective and focus on technologies of particular interest to DOE program activities. Specifically, this document provides site planners with an overview of the status and use of new information technology for their planning consideration.

  5. Technological and life cycle assessment of organics processing odour control technologies

    Energy Technology Data Exchange (ETDEWEB)

    Bindra, Navin [School of Engineering, University of Guelph, 50 Stone Road East, Guelph, Ontario N1G2W1 (Canada); Dubey, Brajesh, E-mail: bkdubey@civil.iitkgp.ernet.in [School of Engineering, University of Guelph, 50 Stone Road East, Guelph, Ontario N1G2W1 (Canada); Environmental Engineering Division, Department of Civil Engineering, Indian Institute of Technology, Kharagpur, West Bengal 721302 (India); Dutta, Animesh [School of Engineering, University of Guelph, 50 Stone Road East, Guelph, Ontario N1G2W1 (Canada)

    2015-09-15

    As more municipalities and communities across developed world look towards implementing organic waste management programmes or upgrading existing ones, composting facilities are emerging as a popular choice. However, odour from these facilities continues to be one of the most important concerns in terms of cost & effective mitigation. This paper provides a technological and life cycle assessment of some of the different odour control technologies and treatment methods that can be implemented in organics processing facilities. The technological assessment compared biofilters, packed tower wet scrubbers, fine mist wet scrubbers, activated carbon adsorption, thermal oxidization, oxidization chemicals and masking agents. The technologies/treatment methods were evaluated and compared based on a variety of operational, usage and cost parameters. Based on the technological assessment it was found that, biofilters and packed bed wet scrubbers are the most applicable odour control technologies for use in organics processing faculties. A life cycle assessment was then done to compare the environmental impacts of the packed-bed wet scrubber system, organic (wood-chip media) bio-filter and inorganic (synthetic media) bio-filter systems. Twelve impact categories were assessed; cumulative energy demand (CED), climate change, human toxicity, photochemical oxidant formation, metal depletion, fossil depletion, terrestrial acidification, freshwater eutrophication, marine eutrophication, terrestrial eco-toxicity, freshwater eco-toxicity and marine eco-toxicity. The results showed that for all impact categories the synthetic media biofilter had the highest environmental impact, followed by the wood chip media bio-filter system. The packed-bed system had the lowest environmental impact for all categories. - Highlights: • Assessment of odour control technologies for organics processing facilities. • Comparative life cycle assessment of three odour control technologies was conducted

  6. Nuclear proliferation and civilian nuclear power. Report of the Nonproliferation Alternative Systems Assessment Program. Volume IX. Reactor and fuel cycle description

    Energy Technology Data Exchange (ETDEWEB)

    1980-06-01

    The Nonproliferation Alterntive Systems Assessment Program (NASAP) has characterized and assessed various reactor/fuel-cycle systems. Volume IX provides, in summary form, the technical descriptions of the reactor/fuel-cycle systems studied. This includes the status of the system technology, as well as a discussion of the safety, environmental, and licensing needs from a technical perspective. This information was then used in developing the research, development, and demonstration (RD and D) program, including its cost and time frame, to advance the existing technology to the level needed for commercial use. Wherever possible, the cost data are given as ranges to reflect the uncertainties in the estimates.

  7. Nuclear proliferation and civilian nuclear power. Report of the Nonproliferation Alternative Systems Assessment Program. Volume IX. Reactor and fuel cycle description

    International Nuclear Information System (INIS)

    1980-06-01

    The Nonproliferation Alterntive Systems Assessment Program (NASAP) has characterized and assessed various reactor/fuel-cycle systems. Volume IX provides, in summary form, the technical descriptions of the reactor/fuel-cycle systems studied. This includes the status of the system technology, as well as a discussion of the safety, environmental, and licensing needs from a technical perspective. This information was then used in developing the research, development, and demonstration (RD and D) program, including its cost and time frame, to advance the existing technology to the level needed for commercial use. Wherever possible, the cost data are given as ranges to reflect the uncertainties in the estimates

  8. Technology assessment of solar energy utilization

    Science.gov (United States)

    Jaeger, F.

    1985-11-01

    The general objectives and methods of Technology Assessment (TA) are outlined. Typical analysis steps of a TA for solar energy are reviewed: description of the technology and its further development; identification of impact areas; analysis of boundary conditions and definition of scenarios; market penetration of solar technologies; projection of consequences in areas of impact; and assessment of impacts and identification of options for action.

  9. Drug delivery system innovation and Health Technology Assessment: Upgrading from Clinical to Technological Assessment.

    Science.gov (United States)

    Panzitta, Michele; Bruno, Giorgio; Giovagnoli, Stefano; Mendicino, Francesca R; Ricci, Maurizio

    2015-11-30

    Health Technology Assessment (HTA) is a multidisciplinary health political instrument that evaluates the consequences, mainly clinical and economical, of a health care technology; the HTA aim is to produce and spread information on scientific and technological innovation for health political decision making process. Drug delivery systems (DDS), such as nanocarriers, are technologically complex but they have pivotal relevance in therapeutic innovation. The HTA process, as commonly applied to conventional drug evaluation, should upgrade to a full pharmaceutical assessment, considering the DDS complexity. This is useful to study more in depth the clinical outcome and to broaden its critical assessment toward pharmaceutical issues affecting the patient and not measured by the current clinical evidence approach. We draw out the expertise necessary to perform the pharmaceutical assessment and we propose a format to evaluate the DDS technological topics such as formulation and mechanism of action, physicochemical characteristics, manufacturing process. We integrated the above-mentioned three points in the Evidence Based Medicine approach, which is data source for any HTA process. In this regard, the introduction of a Pharmaceutics Expert figure in the HTA could be fundamental to grant a more detailed evaluation of medicine product characteristics and performances and to help optimizing DDS features to overcome R&D drawbacks. Some aspects of product development, such as manufacturing processes, should be part of the HTA as innovative manufacturing processes allow new products to reach more effectively patient bedside. HTA so upgraded may encourage resource allocating payers to invest in innovative technologies and providers to focus on innovative material properties and manufacturing processes, thus contributing to bring more medicines in therapy in a sustainable manner. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Reliability of Volumetry and Perimetry to Assess Knee Volume.

    Science.gov (United States)

    Nunes, Guilherme S; Yamashitafuji, Igor; Wageck, Bruna; Teixeira, Guilherme Garcia; Karloh, Manuela; de Noronha, Marcos

    2016-08-24

    The treatment of edema after a knee injury is usually 1 of the main objectives during rehabilitation. To assess the success of treatment, 2 methods are commonly used in clinical practice: volumetry and perimetry. To investigate the intra- and interassessor reliability of volumetry and perimetry to assess knee volume. Cross-sectional. Laboratory. 45 healthy participants (26 women) with mean age of 22.4 ± 2.8 y. Knee volume was assessed by 3 assessors (A, B, and C) with 3 methods (lower-limb volumetry [LLV], knee volumetry [KV], and knee perimetry [KP]). Assessor A was the most-experienced assessor, and assessor C, the least experienced. LLV and KV were performed with participants in the orthostatic position, while KP was performed with participants in supine. For the interassessor analysis, the ICC2,1 was high (.82) for KV and very high for LLV (.99) and KP (.99). For the intra-assessor analysis, ICC2,1 ranged from moderate to high for KV (.69-.83) and was very high for LLV (.99) and KP (.97-.99). KV, LLV, and KP are reliable methods, both intra- and interassessor, to measure knee volume.

  11. Employing a Grinding Technology to Assess the Microbial Density for Encapsulated Organisms

    Science.gov (United States)

    Benardini, James N.; Morales, Fabian; Schubert, Wayne W.; Kazarians, Gayane A.; Koukol, Robert C.

    2012-01-01

    Projects that utilize large volumes of nonmetallic materials of planetary protection concern pose a challenge to their bioburden budget, as the most conservative value of 30 spores/cubic cm is typically used. The standard laboratory procedures do not provide any direction into the methodologies to understand the embedded bioburden within such nonmetallic components such as adhesives, insulation, or paint. A tailored, novel, destructive hardware technology employing a household box grater was developed to assess the embedded bioburden within the adhesives, insulation, and paint for the Mars Science Laboratory (MSL) project.

  12. ASSESSMENT OF QUALITY OF INNOVATIVE TECHNOLOGIES

    OpenAIRE

    Larisa Alexejevna Ismagilova; Nadegda Aleksandrovna Sukhova

    2016-01-01

    We consider the topical issue of implementation of innovative technologies in the aircraft engine building industry. In this industry, products with high reliability requirements are developed and mass-produced. These products combine the latest achievements of science and technology. To make a decision on implementation of innovative technologies, a comprehensive assessment is carried out. It affects the efficiency of the innovations realization. In connection with this, the assessment of qu...

  13. Aircraft Battle Damage Assessment and Repair (ABDAR). Volume 1: Executive Summary

    National Research Council Canada - National Science Library

    Dierker, Ron

    2000-01-01

    .... This volume provides an executive summary and describes the overall program goals, the methodology used to develop the ABDAR technology and a demonstration system, and the results of a field test...

  14. Institutionalising health technology assessment: establishing the Medical Technology Assessment Board in India.

    Science.gov (United States)

    Downey, Laura E; Mehndiratta, Abha; Grover, Ashoo; Gauba, Vijay; Sheikh, Kabir; Prinja, Shankar; Singh, Ravinder; Cluzeau, Francoise A; Dabak, Saudamini; Teerawattananon, Yot; Kumar, Sanjiv; Swaminathan, Soumya

    2017-01-01

    India is at crossroads with a commitment by the government to universal health coverage (UHC), driving efficiency and tackling waste across the public healthcare sector. Health technology assessment (HTA) is an important policy reform that can assist policy-makers to tackle inequities and inefficiencies by improving the way in which health resources are allocated towards cost-effective, appropriate and feasible interventions. The equitable and efficient distribution of health budget resources, as well as timely uptake of good value technologies, are critical to strengthen the Indian healthcare system. The government of India is set to establish a Medical Technology Assessment Board to evaluate existing and new health technologies in India, assist choices between comparable technologies for adoption by the healthcare system and improve the way in which priorities for health are set. This initiative aims to introduce a more transparent, inclusive, fair and evidence-based process by which decisions regarding the allocation of health resources are made in India towards the ultimate goal of UHC. In this analysis article, we report on plans and progress of the government of India for the institutionalisation of HTA in the country. Where India is home to one-sixth of the global population, improving the health services that the population receives will have a resounding impact not only for India but also for global health.

  15. Stratified charge rotary engine critical technology enablement. Volume 2: Appendixes

    Science.gov (United States)

    Irion, C. E.; Mount, R. E.

    1992-01-01

    This second volume of appendixes is a companion to Volume 1 of this report which summarizes results of a critical technology enablement effort with the stratified charge rotary engine (SCRE) focusing on a power section of 0.67 liters (40 cu. in.) per rotor in single and two rotor versions. The work is a continuation of prior NASA Contracts NAS3-23056 and NAS3-24628. Technical objectives are multi-fuel capability, including civil and military jet fuel and DF-2, fuel efficiency of 0.355 Lbs/BHP-Hr. at best cruise condition above 50 percent power, altitude capability of up to 10Km (33,000 ft.) cruise, 2000 hour TBO and reduced coolant heat rejection. Critical technologies for SCRE's that have the potential for competitive performance and cost in a representative light-aircraft environment were examined. Objectives were: the development and utilization of advanced analytical tools, i.e. higher speed and enhanced three dimensional combustion modeling; identification of critical technologies; development of improved instrumentation; and to isolate and quantitatively identify the contribution to performance and efficiency of critical components or subsystems. A family of four-stage third-order explicit Runge-Kutta schemes is derived that required only two locations and has desirable stability characteristics. Error control is achieved by embedding a second-order scheme within the four-stage procedure. Certain schemes are identified that are as efficient and accurate as conventional embedded schemes of comparable order and require fewer storage locations.

  16. Data summary of municipal solid waste management alternatives. Volume 3, Appendix A: Mass burn technologies

    Energy Technology Data Exchange (ETDEWEB)

    None

    1992-10-01

    This appendix on Mass Burn Technologies is the first in a series designed to identify, describe and assess the suitability of several currently or potentially available generic technologies for the management of municipal solid waste (MSW). These appendices, which cover eight core thermoconversion, bioconversion and recycling technologies, reflect public domain information gathered from many sources. Representative sources include: professional journal articles, conference proceedings, selected municipality solid waste management plans and subscription technology data bases. The information presented is intended to serve as background information that will facilitate the preparation of the technoeconomic and life cycle mass, energy and environmental analyses that are being developed for each of the technologies. Mass burn has been and continues to be the predominant technology in Europe for the management of MSW. In the United States, the majority of the existing waste-to-energy projects utilize this technology and nearly 90 percent of all currently planned facilities have selected mass burn systems. Mass burning generally refers to the direct feeding and combustion of municipal solid waste in a furnace without any significant waste preprocessing. The only materials typically removed from the waste stream prior to combustion are large bulky objects and potentially hazardous or undesirable wastes. The technology has evolved over the last 100 or so years from simple incineration to the most highly developed and commercially proven process available for both reducing the volume of MSW and for recovering energy in the forms of steam and electricity. In general, mass burn plants are considered to operate reliably with high availability.

  17. Identification and assessment of site treatment plan implementation opportunities for emerging technologies

    International Nuclear Information System (INIS)

    Bernard, E.A.

    1995-01-01

    The Department of Energy (DOE), in response to the 1992 Federal Facility Compliance Act, has prepared Site Treatment Plans (STP) for the approximately 2,000 waste streams identified within its mixed waste inventory Concurrently, emerging mixed waste treatment technologies are in final development. This paper defines a three-phase process to identify and assess implementation opportunities for these emerging technologies within the STP. It highlights the first phase, functional matching of expected treatment capabilities with proposed treatment requirements. Matches are based on treatment type, regulated contaminant and waste matrix type, for both capabilities and requirements. Results identify specific waste streams and volumes that could be treated by each emerging technology. A study for Plasma Hearth Process, Delphi DETOX sm , Supercritical Water Oxidation and Vitrification shows that about 200,000 ml of DOE's mixed waste inventory can potentially be treated by one or more of these emerging technologies. Actual implementations are small fractions of the treatable inventory. Differences between potential and actual implementations must be minimized to accrue optimum benefit from implementation of emerging or alternative treatment technologies. Functional matching is the first phase in identifying and quantifying benefits, addressing technology system and treatment issues, and providing, in part, the basis for STP implementation decisions. DOE, through EM's Office of Technology Development, has funded this work

  18. Assessing the quality of the volume-outcome relationship in uro-oncology.

    Science.gov (United States)

    Mayer, Erik K; Purkayastha, Sanjay; Athanasiou, Thanos; Darzi, Ara; Vale, Justin A

    2009-02-01

    To assess systematically the quality of evidence for the volume-outcome relationship in uro-oncology, and thus facilitate the formulating of health policy within this speciality, as 'Implementation of Improving Outcome Guidance' has led to centralization of uro-oncology based on published studies that have supported a 'higher volume-better outcome' relationship, but improved awareness of methodological drawbacks in health service research has questioned the strength of this proposed volume-outcome relationship. We systematically searched previous relevant reports and extracted all articles from 1980 onwards assessing the volume-outcome relationship for cystectomy, prostatectomy and nephrectomy at the institution and/or surgeon level. Studies were assessed for their methodological quality using a previously validated rating system. Where possible, meta-analytical methods were used to calculate overall differences in outcome measures between low and high volume healthcare providers. In all, 22 studies were included in the final analysis; 19 of these were published in the last 5 years. Only four studies appropriately explored the effect of both the institution and surgeon volume on outcome measures. Mortality and length of stay were the most frequently measured outcomes. The median total quality scores within each of the operation types were 8.5, 9 and 8 for cystectomy, prostatectomy and nephrectomy, respectively (possible maximum score 18). Random-effects modelling showed a higher risk of mortality in low-volume institutions than in higher-volume institutions for both cystectomy and nephrectomy (odds ratio 1.88, 95% confidence interval 1.54-2.29, and 1.28, 1.10-1.49, respectively). The methodological quality of volume-outcome research as applied to cystectomy, prostatectomy and nephrectomy is only modest at best. Accepting several limitations, pooled analysis confirms a higher-volume, lower-mortality relationship for cystectomy and nephrectomy. Future research should

  19. Technology Assessment Need: Review on Attractiveness and Competitiveness

    Science.gov (United States)

    Salwa Sait, Siti; Merlinda Muharam, Farrah; Chin, Thoo Ai; Sulaiman, Zuraidah

    2017-06-01

    Technology assessment is crucial in managing technology for the purpose of technology exploitation. With business environment continuously changing, firms have to address this issue critically as technology is considered one of the important elements to evaluate performance and gain competitive advantage. Missteps in deciding the best technology to be developed, employed or maintained would cost the firm overall value. To fulfil the need of finding the appropriate scale to assess suitable technology, this paper summarizes that technology assessment (TA) should cover two main aspects, namely technology attractiveness and competitiveness. These components are seen capable to link the scale suggested towards evaluation of financial and non-financial performance towards competitive advantage.

  20. What influences the choice of assessment methods in health technology assessments? Statistical analysis of international health technology assessments from 1989 to 2002.

    Science.gov (United States)

    Draborg, Eva; Andersen, Christian Kronborg

    2006-01-01

    Health technology assessment (HTA) has been used as input in decision making worldwide for more than 25 years. However, no uniform definition of HTA or agreement on assessment methods exists, leaving open the question of what influences the choice of assessment methods in HTAs. The objective of this study is to analyze statistically a possible relationship between methods of assessment used in practical HTAs, type of assessed technology, type of assessors, and year of publication. A sample of 433 HTAs published by eleven leading institutions or agencies in nine countries was reviewed and analyzed by multiple logistic regression. The study shows that outsourcing of HTA reports to external partners is associated with a higher likelihood of using assessment methods, such as meta-analysis, surveys, economic evaluations, and randomized controlled trials; and with a lower likelihood of using assessment methods, such as literature reviews and "other methods". The year of publication was statistically related to the inclusion of economic evaluations and shows a decreasing likelihood during the year span. The type of assessed technology was related to economic evaluations with a decreasing likelihood, to surveys, and to "other methods" with a decreasing likelihood when pharmaceuticals were the assessed type of technology. During the period from 1989 to 2002, no major developments in assessment methods used in practical HTAs were shown statistically in a sample of 433 HTAs worldwide. Outsourcing to external assessors has a statistically significant influence on choice of assessment methods.

  1. PACS/IMAC technology assessment

    OpenAIRE

    Schilling, Ronald B.

    1997-01-01

    According to Peter Ogle of Digital Imaging (San Francisco, CA), “Radiologists should help identify common values for the use of information technology in medicine.” Achieving a set of common values often requires a framework for organizing the thought process involved. That is the focus of this article in addressing the subject of picture archiving and communication system (PACS) technology assessment.

  2. A reliable and consistent production technology for high volume compacted graphite iron castings

    Directory of Open Access Journals (Sweden)

    Liu Jincheng

    2014-07-01

    Full Text Available The demands for improved engine performance, fuel economy, durability, and lower emissions provide a continual challenge for engine designers. The use of Compacted Graphite Iron (CGI has been established for successful high volume series production in the passenger vehicle, commercial vehicle and industrial power sectors over the last decade. The increased demand for CGI engine components provides new opportunities for the cast iron foundry industry to establish efficient and robust CGI volume production processes, in China and globally. The production window range for stable CGI is narrow and constantly moving. Therefore, any one step single addition of magnesium alloy and the inoculant cannot ensure a reliable and consistent production process for complicated CGI engine castings. The present paper introduces the SinterCast thermal analysis process control system that provides for the consistent production of CGI with low nodularity and reduced porosity, without risking the formation of flake graphite. The technology is currently being used in high volume Chinese foundry production. The Chinese foundry industry can develop complicated high demand CGI engine castings with the proper process control technology.

  3. Technologies Assessing Limb Bradykinesia in Parkinson’s Disease

    Science.gov (United States)

    Hasan, Hasan; Athauda, Dilan S.; Foltynie, Thomas; Noyce, Alastair J.

    2017-01-01

    Background: The MDS-UPDRS (Movement Disorders Society – Unified Parkinson’s Disease Rating Scale) is the most widely used scale for rating impairment in PD. Subscores measuring bradykinesia have low reliability that can be subject to rater variability. Novel technological tools can be used to overcome such issues. Objective: To systematically explore and describe the available technologies for measuring limb bradykinesia in PD that were published between 2006 and 2016. Methods: A systematic literature search using PubMed (MEDLINE), IEEE Xplore, Web of Science, Scopus and Engineering Village (Compendex and Inspec) databases was performed to identify relevant technologies published until 18 October 2016. Results: 47 technologies assessing bradykinesia in PD were identified, 17 of which offered home and clinic-based assessment whilst 30 provided clinic-based assessment only. Of the eligible studies, 7 were validated in a PD patient population only, whilst 40 were tested in both PD and healthy control groups. 19 of the 47 technologies assessed bradykinesia only, whereas 28 assessed other parkinsonian features as well. 33 technologies have been described in additional PD-related studies, whereas 14 are not known to have been tested beyond the pilot phase. Conclusion: Technology based tools offer advantages including objective motor assessment and home monitoring of symptoms, and can be used to assess response to intervention in clinical trials or routine care. This review provides an up-to-date repository and synthesis of the current literature regarding technology used for assessing limb bradykinesia in PD. The review also discusses the current trends with regards to technology and discusses future directions in development. PMID:28222539

  4. Health technology assessment. Evaluation of biomedical innovative technologies.

    Science.gov (United States)

    Turchetti, Giuseppe; Spadoni, Enza; Geisler, Eliezer Elie

    2010-01-01

    This article describes health technology assessment (HTA) as an evaluation tool that applies systematic methods of inquiry to the generation and use of health technologies and new products. The focus of this article is on the contributions of HTA to the management of the new product development effort in the biomedical organization. Critical success factors (CSFs) are listed, and their role in assessing success is defined and explained. One of the conclusions of this article is that HTA is a powerful tool for managers in the biomedical sector, allowing them to better manage their innovation effort in their continuing struggle for competitiveness and survival.

  5. Health technology assessment (HTA): a brief introduction of history and the current status in the field of cardiology under the economic crisis.

    Science.gov (United States)

    Fanourgiakis, John; Kanoupakis, Emmanuel

    2015-08-01

    In a time of economic recession health technology assessment is an established aid in decision making in many countries in order to identify cost-containment policy options. Moreover, as the volume, complexity, and cost of new medical technology increases, the need for evaluating benefits, risks and costs becomes increasingly important. In recent years there has been a proliferation of health technology assessment initiatives internationally, aimed in introducing rationality in the decision-making process, informing reimbursement, providing clinical guidance on the use of medical technologies across the world in an evidence-based decision-making environment and in pricing decisions. © 2015 Chinese Cochrane Center, West China Hospital of Sichuan University and Wiley Publishing Asia Pty Ltd.

  6. Health technology assessment in India: the potential for improved healthcare decision-making.

    Science.gov (United States)

    Kumar, Mrityunjai; Ebrahim, Shah; Taylor, Fiona C; Chokshi, Maulik; Gabbay, John

    2014-01-01

    Health technology assessment (HTA) is a multidisciplinary approach that uses clinical effectiveness, cost-effectiveness, policy and ethical perspectives to provide evidence upon which rational decisions on the use of health technologies can be made. It can be used for a single stand-alone technology (e.g. a drug, a device), complex interventions (e.g. a rehabilitation service) and can also be applied to individual patient care and to public health. It is a tool for enabling the assessment and comparison of health technologies using the same metric of cost-effectiveness. This process benefits the patient, the health service, the healthcare payer and the technology producer as only technologies that are considered cost-effective are promoted for widespread use. This leads to greater use of effective technologies and greater health gain. The decision-making process in healthcare in India is complex owing to multiplicity of organizations with overlapping mandates. Often the decision-making is not evidence-based and there is no mechanism of bridging the gap between evidence and policy. Elsewhere, HTA is a frequently used tool in informing policy decisions in both resource-rich and resource-poor countries. Despite national organizations producing large volumes of research and clinical guidelines, India has not yet introduced a formal HTA programme. The incremental growth in healthcare products, services, innovation in affordable medical devices and a move towards universal healthcare, needs to be underpinned with an evidencebase which focuses on effectiveness, safety, affordability and acceptability to maximize the benefits that can be gained with a limited healthcare budget. Establishing HTA as a formal process in India, independent of healthcare providers, funders and technology producers, together with a framework for linking HTA to policy-making, would help ensure that the population gets better access to appropriate healthcare in the future. Copyright 2014, NMJI.

  7. Relations between brain volumes, neuropsychological assessment and parental questionnaire in prematurely born children.

    Science.gov (United States)

    Lind, Annika; Haataja, Leena; Rautava, Liisi; Väliaho, Anniina; Lehtonen, Liisa; Lapinleimu, Helena; Parkkola, Riitta; Korkman, Marit

    2010-05-01

    The objective of this study is to assess the relationship between brain volumes at term equivalent age and neuropsychological functions at 5 years of age in very low birth weight (VLBW) children, and to compare the results from a neuropsychological assessment and a parental questionnaire at 5 years of age. The study group included a regional cohort of 97 VLBW children and a control group of 161 children born at term. At term equivalent age, brain magnetic resonance imaging (MRI) was performed on the VLBW children, and analysed for total and regional brain volumes. At 5 years of age, a psychologist assessed the neuropsychological performance with NEPSY II, and parents completed the Five to fifteen (FTF) questionnaire on development and behaviour. The results of the control group were used to give the age-specific reference values. No significant associations were found between the brain volumes and the NEPSY II domains. As for the FTF, significant associations were found between a smaller total brain tissue volume and poorer executive functions, between a smaller cerebellar volume and both poorer executive functions and motor skills, and, surprisingly, between a larger volume of brainstem and poorer language functions. Even after adjustment for total brain tissue volume, the two associations between the cerebellar volume and the FTF domains remained borderline significant (P = 0.05). The NEPSY II domains Executive Functioning, Language and Motor Skills were significantly associated with the corresponding FTF domains. In conclusion, altered brain volumes at term equivalent age appear to affect development still at 5 years of age. The FTF seems to be a good instrument when used in combination with other neuropsychological assessment.

  8. Distributed technologies in California's energy future: A preliminary report. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    Christensen, M.; Craig, P.; McGuire, C.B.; Simmons, M. (eds.)

    1977-09-01

    The chapters in Volume 2 of Distributed Energy Systems in California's Future are: Environmental Impacts of Alternative Energy Technologies for California; Land Use Configurations and the Utilization of Distributive Energy Technology; Land Use Implications of a Dispersed Energy Path; Belief, Behavior, and Technologies as Driving Forces in Transitional Stages--The People Problem in Dispersed Energy Futures; Development of an Energy Attitude Survey; Interventions to Influence Firms Toward the Adoption of ''Soft'' Energy Technology; The Entry of Small Firms into Distributed Technology Energy Industries; Short-Term Matching of Supply and Demand in Electrical Systems with Renewable Sources; Vulnerability of Renewable Energy Systems; and District Heating for California.

  9. Independent Assessment of Technology Characterizations to Support the Biomass Program Annual State-of-Technology Assessments

    Energy Technology Data Exchange (ETDEWEB)

    Yeh, B.

    2011-03-01

    This report discusses an investigation that addressed two thermochemical conversion pathways for the production of liquid fuels and addressed the steps to the process, the technology providers, a method for determining the state of technology and a tool to continuously assess the state of technology. This report summarizes the findings of the investigation as well as recommendations for improvements for future studies.

  10. Technology Assessment and Roadmap for the Emergency Radiation Dose Assessment Program

    International Nuclear Information System (INIS)

    Turteltaub, K W; Hartman-Siantar, C; Easterly, C; Blakely, W

    2005-01-01

    A Joint Interagency Working Group (JIWG) under the auspices of the Department of Homeland Security Office of Research and Development conducted a technology assessment of emergency radiological dose assessment capabilities as part of the overall need for rapid emergency medical response in the event of a radiological terrorist event in the United States. The goal of the evaluation is to identify gaps and recommend general research and development needs to better prepare the Country for mitigating the effects of such an event. Given the capabilities and roles for responding to a radiological event extend across many agencies, a consensus of gaps and suggested development plans was a major goal of this evaluation and road-mapping effort. The working group consisted of experts representing the Departments of Homeland Security, Health and Human Services (Centers for Disease Control and the National Institutes of Health), Food and Drug Administration, Department of Defense and the Department of Energy's National Laboratories (see appendix A for participants). The specific goals of this Technology Assessment and Roadmap were to: (1) Describe the general context for deployment of emergency radiation dose assessment tools following terrorist use of a radiological or nuclear device; (2) Assess current and emerging dose assessment technologies; and (3) Put forward a consensus high-level technology roadmap for interagency research and development in this area. This report provides a summary of the consensus of needs, gaps and recommendations for a research program in the area of radiation dosimetry for early response, followed by a summary of the technologies available and on the near-term horizon. We then present a roadmap for a research program to bring present and emerging near-term technologies to bear on the gaps in radiation dose assessment and triage. Finally we present detailed supporting discussion on the nature of the threats we considered, the status of technology

  11. Technology Assessment and Roadmap for the Emergency Radiation Dose Assessment Program

    Energy Technology Data Exchange (ETDEWEB)

    Turteltaub, K W; Hartman-Siantar, C; Easterly, C; Blakely, W

    2005-10-03

    A Joint Interagency Working Group (JIWG) under the auspices of the Department of Homeland Security Office of Research and Development conducted a technology assessment of emergency radiological dose assessment capabilities as part of the overall need for rapid emergency medical response in the event of a radiological terrorist event in the United States. The goal of the evaluation is to identify gaps and recommend general research and development needs to better prepare the Country for mitigating the effects of such an event. Given the capabilities and roles for responding to a radiological event extend across many agencies, a consensus of gaps and suggested development plans was a major goal of this evaluation and road-mapping effort. The working group consisted of experts representing the Departments of Homeland Security, Health and Human Services (Centers for Disease Control and the National Institutes of Health), Food and Drug Administration, Department of Defense and the Department of Energy's National Laboratories (see appendix A for participants). The specific goals of this Technology Assessment and Roadmap were to: (1) Describe the general context for deployment of emergency radiation dose assessment tools following terrorist use of a radiological or nuclear device; (2) Assess current and emerging dose assessment technologies; and (3) Put forward a consensus high-level technology roadmap for interagency research and development in this area. This report provides a summary of the consensus of needs, gaps and recommendations for a research program in the area of radiation dosimetry for early response, followed by a summary of the technologies available and on the near-term horizon. We then present a roadmap for a research program to bring present and emerging near-term technologies to bear on the gaps in radiation dose assessment and triage. Finally we present detailed supporting discussion on the nature of the threats we considered, the status of

  12. 20 Years of Technology and Language Assessment in "Language Learning & Technology"

    Science.gov (United States)

    Chapelle, Carol A.; Voss, Erik

    2016-01-01

    This review article provides an analysis of the research from the last two decades on the theme of technology and second language assessment. Based on an examination of the assessment scholarship published in "Language Learning & Technology" since its launch in 1997, we analyzed the review articles, research articles, book reviews,…

  13. The economic impact of regional waste disposal on advanced volume reduction technologies

    International Nuclear Information System (INIS)

    McArthur, W.C.; Kniazewycz, B.G.

    1983-01-01

    Waste volume reduction has received increased emphasis over the past decade as annual operating costs have risen from $250,000/year to $3,500,000 for 1983. Emphasis has been given to developing and designing into new nuclear plants process and DAW volume reduction technologies such as fluidized-bed dryers incinerators, and evaporative-solidification systems. The basis for these systems was originally the correct perception that a crisis would be reached with the, then available, shallow land disposal sites which would increase costs substantially and possible jeopardize power plant operations. With the passage of the Low-Level Waste Policy Act of 1980 and increased emphasis on interim on-site storage of low-level waste, the ''economics of volume reduction'' are susceptible to increased uncertainties. This paper reviews some previous volume reduction economic analyses and evaluates the revised economics based upon the development of regional waste disposal sites, improved waste generation and processing practices, and the increased use of interim on-site storage. Several case studies are presented

  14. A plasma melting technology for volume reduction of noncombustible radioactive waste in Korea

    International Nuclear Information System (INIS)

    Song, Myung Jae; Moon, Young Pyo

    1998-01-01

    In Korea, there is a strong need for the development of radioactive waste volume reduction technology. Korea Electric Power Research Institute (KEPRI) has been searching for ways to reduce the radioactive volume significantly and to produce stable waste forms. In particular, plasma treatment technology has caught KEPR's attention for treating noncombustible radwaste because this technology may far surpass conventional methods. The potential for greater control of temperature, faster reaction times, better control of processing, lower capital costs, greater throughput and more efficient use of energy is there. For the plasma melting study of noncombustible waste, KEPRI has leased a lab scale multipurpose plasma furnace system and performed preliminary tests. Using simulated noncombustible waste based on field survey data from nuclear power plants, lab scale melting experiments have been carried out. The properties of molten slag vary with additives and noncombustible waste materials. KEPRI's current study is focused on finding an optimum composition ratio of various noncombustible wastes for melting, investigating physical properties of molten slag, and obtaining operating parameters for continuous operation. (author)

  15. An Assessment of the Technical Readiness of the Vapor Phase Catalytic Ammonia Removal Process (VPCAR) Technology

    Science.gov (United States)

    Flynn, Michael

    2000-01-01

    This poster provides an assessment of the technical readiness of the Vapor Phase Catalytic Ammonia Removal Process (VPCAR). The VPCAR technology is a fully regenerative water recycling technology designed specifically for applications such as a near term Mars exploration mission. The VPCAR technology is a highly integrated distillation/catalytic oxidation based water processor. It is designed to accept a combined wastewater stream (urine, condensate, and hygiene) and produces potable water in a single process step which requires -no regularly scheduled re-supply or maintenance for a 3 year mission. The technology is designed to be modular and to fit into a volume comparable to a single International Space Station Rack (when sized for a crew of 6). This poster provides a description of the VPCAR technology and a summary of the current performance of the technology. Also provided are the results of two separate NASA sponsored system trade studies which investigated the potential payback of further development of the VPCAR technology.

  16. Proceedings of the environmental technology through industry partnership conference. Volume 1

    International Nuclear Information System (INIS)

    Kothari, V.P.

    1995-10-01

    The overall objective of this conference was to review the latest environmental and waste management technologies being developed under the sponsorship of METC. The focus of this conference was also to address the accomplishments and barriers affecting private sector, and lay the groundwork for future technology development initiatives and opportunities. 26 presentations were presented in: Mixed waste characterization, treatment, and disposal; Contaminant plume containment and remediation; and Decontamination and decommissioning. In addition there were 10 Focus Area presentations, 31 Poster papers covering all Focus Areas, and two panel discussions on: Mixed waste characterization, treatment, and disposal issues; and the application, evaluation, and acceptance of in-situ and ex-situ plume remediation technologies. Volume 1 contains the keynote address, 15 poster papers, 5 papers on mixed waste characterization, treatment, and disposal, and 13 papers on decontamination and decommissioning. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database

  17. Proceedings of the environmental technology through industry partnership conference. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    Kothari, V.P.

    1995-10-01

    The overall objective of this conference was to review the latest environmental and waste management technologies being developed under the sponsorship of METC. The focus of this conference was also to address the accomplishments and barriers affecting private sector, and lay the groundwork for future technology development initiatives and opportunities. 26 presentations were presented in: Mixed waste characterization, treatment, and disposal; Contaminant plume containment and remediation; and Decontamination and decommissioning. In addition there were 10 Focus Area presentations, 31 Poster papers covering all Focus Areas, and two panel discussions on: Mixed waste characterization, treatment, and disposal issues; and the Application, evaluation, and acceptance of in-situ and ex-situ plume remediation technologies. Volume 2 contains 16 papers in a poster session and 8 papers in the contaminant plume containment and remediation and landfill stabilization Focus Areas. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database.

  18. Proceedings of the environmental technology through industry partnership conference. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Kothari, V.P.

    1995-10-01

    The overall objective of this conference was to review the latest environmental and waste management technologies being developed under the sponsorship of METC. The focus of this conference was also to address the accomplishments and barriers affecting private sector, and lay the groundwork for future technology development initiatives and opportunities. 26 presentations were presented in: Mixed waste characterization, treatment, and disposal; Contaminant plume containment and remediation; and Decontamination and decommissioning. In addition there were 10 Focus Area presentations, 31 Poster papers covering all Focus Areas, and two panel discussions on: Mixed waste characterization, treatment, and disposal issues; and the application, evaluation, and acceptance of in-situ and ex-situ plume remediation technologies. Volume 1 contains the keynote address, 15 poster papers, 5 papers on mixed waste characterization, treatment, and disposal, and 13 papers on decontamination and decommissioning. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database.

  19. Assessment of the breast volume by a new simple formula

    Directory of Open Access Journals (Sweden)

    El-Oteify Mahmoud

    2006-01-01

    Full Text Available Background: With the recent introduction of improved techniques for plastic surgery of the breast and increased public awareness toward these procedures, plastic surgeons are continuously trying to improve their methods and results to reach perfection. Assessment of the breast volume is an important issue prior to the use of breast implants in any aesthetic or reconstructive breast surgery. Previous methods to measure breast volume have included use of a simple bra and breast cup size, cumbersome fluid displacement, appliances and approximate visual estimation. Objectives: In this work we have tried to develop an easy method for assessment of the breast volume for both the patient and the the surgeon through a simple mathematical formula. Materials and Methods: Fifty two volunteers were included in this study. For every one, general parameters including age, weight and height were recorded. Local breast measurements and water volume displacement were also recorded. Results: The collected data were statistically correlated. Using the analyzed data, the breast volume was calculated through a simple and direct formula on the basis of the breast circumference. Conclusion: Our method has, as its principle, the use of an accurate and simple formula, which is based only on one measurement. This is easy for both the patient and the plastic surgeon. This equation is not only a significant technical advantage for the surgeon, but also provides a universal standardization of the breast volume.

  20. Social Shaping in Danish Technology Assessment

    DEFF Research Database (Denmark)

    Hansen, Anne Grethe; Clausen, Christian

    2003-01-01

    The term ‘social shaping of technology’ has been used broadly as a response to techno-economic deterministic understandings of the relations between technology and society. Social shaping has brought together analysts from different backgrounds who share a common interest in the role of social an...... in these projects contributed to new insights into the processes of technological change and thus to policy formulation. The social shaping perspective and technology assessment experiences are suggested as important guides to future technology strategies....... and political action for technology change. The authors of this article suggest that the social shaping perspective draws on lessons from technology assessments of earlier decades, lessons about the role of technology debate, participation and democratic control. We suggest that these are important......The term ‘social shaping of technology’ has been used broadly as a response to techno-economic deterministic understandings of the relations between technology and society. Social shaping has brought together analysts from different backgrounds who share a common interest in the role of social...

  1. European utility requirements (EUR) volume 3 assessment for AP1000

    International Nuclear Information System (INIS)

    Saiu, G.; Demetri, K.J.

    2005-01-01

    The EUR (European Utility Requirements) Volume 3 is intended to report the Plant Description, the Compliance Assessment to EUR Volumes 1 and 2, and finally, the Specific Requirements for each specific Nuclear Power Plant Design considered by the EUR. Five subsets of EUR Volume 3, based on EUR Revision B, are already published; all of which are next generation plant designs being developed for Europe beyond 2000. They include : 1) EP1000 - Passive Pressurized Light Water Reactor (3-Loop, 1000 MWe) 2) EPR - Evolutionary Pressurized Light Water Reactor (1500 MWe) 3) BWR90/90+ - Evolutionary Boiling Water Reactor (1400 MWe) 4) ABWR - Evolutionary Boiling Water Reactor (1400 MWe) 5) SWR 1000 - Boiling Water Reactor With Passive Features (1000 MWe) In addition, the following subsets are currently being developed: 1) AP1000 - Passive Pressurized Light Water Reactor (2-Loop, 1117 MWe) 2) VVER AES 92 - Pressurized Water Reactor With Passive Features (1000 MWe) The purpose of this paper is to provide an overview of the program, which started in January 2004 with the EUR group to prepare an EUR Volume 3 Subset for the AP1000 nuclear plant design. The AP1000 EUR compliance assessment, to be performed against EUR Revision C requirements, is an important step for the evaluation of the AP1000 design for application in Europe. The AP1000 compliance assessment is making full use of AP1000 licensing documentation, EPP Phase 2 design activities and EP1000 EUR detailed compliance assessment. As of today, nearly all of the EUR Chapters have been discussed within the EUR Coordination Group. Based on the results of the compliance assessment, it can be stated that the AP1000 design shows a good level of compliance with the EUR Revision C requirements. Nevertheless, the compliance assessment has highlighted areas for where the AP1000 plant deviates from the EUR. The EPP design group has selected the most significant ones for performing detailed studies to quantify the degree of compliance

  2. Assessment of the adequacy of bronchial stenting by flow-volume loops

    Energy Technology Data Exchange (ETDEWEB)

    McLaren, Clare A.; Roebuck, Derek J. [Great Ormond Street Hospital for Children, Department of Radiology, London (United Kingdom); Pigott, Nick; Elliott, Martin J. [Great Ormond Street Hospital for Children, Cardiothoracic Unit, London (United Kingdom); Dunne, Catherine [Great Ormond Street Hospital for Children, Department of Physiotherapy, London (United Kingdom)

    2006-08-15

    Airway compression is a common problem in children with certain forms of congenital heart disease. Although various surgical approaches are available to overcome this form of airway obstruction, internal stenting is necessary in a minority of patients. It can be difficult to assess the success of stenting at the time of the procedure, and the interval to successful extubation is usually used as an outcome measure. Measurement of relevant parameters of respiratory physiology with flow-volume and volume-pressure loops permits immediate quantitative assessment of the adequacy of stenting. A 3-month-old infant who underwent bronchial stenting and physiological assessment at the time of the procedure is described. (orig.)

  3. Assessment of the adequacy of bronchial stenting by flow-volume loops

    International Nuclear Information System (INIS)

    McLaren, Clare A.; Roebuck, Derek J.; Pigott, Nick; Elliott, Martin J.; Dunne, Catherine

    2006-01-01

    Airway compression is a common problem in children with certain forms of congenital heart disease. Although various surgical approaches are available to overcome this form of airway obstruction, internal stenting is necessary in a minority of patients. It can be difficult to assess the success of stenting at the time of the procedure, and the interval to successful extubation is usually used as an outcome measure. Measurement of relevant parameters of respiratory physiology with flow-volume and volume-pressure loops permits immediate quantitative assessment of the adequacy of stenting. A 3-month-old infant who underwent bronchial stenting and physiological assessment at the time of the procedure is described. (orig.)

  4. 10. National Nuclear Science and Technology Congress Proceedings Book, Volume 2

    International Nuclear Information System (INIS)

    2009-01-01

    X. National Nuclear Science and Technologies Congress was held on 6-9 October 2009 in Mugla, Turkey in the course of collaborative organization undertaken by Turkish Atomic Energy Authority, Mugla University and Sitki Kocman Foundation. This second volume of Proceedings Book contains 91 submitted presentations and 51 of them are full texts on applications of basic nuclear sciences, nuclear energy and safety.

  5. Identification and assessment of site treatment plan implementation opportunities for emerging technologies

    Energy Technology Data Exchange (ETDEWEB)

    Bernard, E.A. [Sandia National Labs., Germantown, MD (United States)

    1995-12-31

    The Department of Energy (DOE), in response to the 1992 Federal Facility Compliance Act, has prepared Site Treatment Plans (STP) for the approximately 2,000 waste streams identified within its mixed waste inventory Concurrently, emerging mixed waste treatment technologies are in final development. This paper defines a three-phase process to identify and assess implementation opportunities for these emerging technologies within the STP. It highlights the first phase, functional matching of expected treatment capabilities with proposed treatment requirements. Matches are based on treatment type, regulated contaminant and waste matrix type, for both capabilities and requirements. Results identify specific waste streams and volumes that could be treated by each emerging technology. A study for Plasma Hearth Process, Delphi DETOX{sup sm}, Supercritical Water Oxidation and Vitrification shows that about 200,000 ml of DOE`s mixed waste inventory can potentially be treated by one or more of these emerging technologies. Actual implementations are small fractions of the treatable inventory. Differences between potential and actual implementations must be minimized to accrue optimum benefit from implementation of emerging or alternative treatment technologies. Functional matching is the first phase in identifying and quantifying benefits, addressing technology system and treatment issues, and providing, in part, the basis for STP implementation decisions. DOE, through EM`s Office of Technology Development, has funded this work.

  6. Technology needs assessment for DOE environmental restoration programs

    International Nuclear Information System (INIS)

    Duray, J.R.; Carlson, T.J.; Carpenter, C.E.; Cummins, L.E.; Daub, G.J.

    1992-01-01

    The 'Technology Needs Assessment Final Report' describes current and planned environmental restoration activity, identifies technologies intended to be used or under consideration, and ranks technology deficiencies in the U.S. Department of Energy's environmental restoration program. Included in the ranking are treatment technologies, characterization technologies, and non-technology issues that affect environmental restoration. Data used for the assessment was gathered during interviews in the spring of 1991 with DOE site personnel responsible for the environmental restoration work. (author)

  7. Development of Integrated Assessment Technology of Risk and Performance

    International Nuclear Information System (INIS)

    Yang, Jun Eon; Kang, Dae Il; Kang, Hyun Gook

    2010-04-01

    The main idea and contents are summarized as below 1) Development of new risk/performance assessment system innovating old labor-intensive risk assessment structure - New consolidated risk assessment technology from various hazard(flood, fire, seismic in NPP) - BOP model development for performance monitoring - Consolidated risk/performance management system for consistency and efficiency of NPP 2) Resolution technology for pending issues in PSA - Base technology for PSA of digital I and C system - Base technology for seismic PSA reflecting domestic seismic characteristics and aging effect - Uncertainty reduction technology for level 2 PSA and best estimation of containment failure frequency 3) Next generation risk/performance assessment technology - Human-induced error reduction technology for efficient operation of a NPP

  8. Technical and Technological Skills Assessment in Laparoscopic Surgery

    Science.gov (United States)

    Chang, Avril; Vincent, Charles

    2006-01-01

    Objectives: Surgical appraisal and revalidation are key components of good surgical practice and training. Assessing technical skills in a structured manner is still not widely used. Laparoscopic surgery also requires the surgeon to be competent in technological aspects of the operation. Methods: Checklists for generic, specific technical, and technological skills for laparoscopic cholecystectomies were constructed. Two surgeons with >12 years postgraduate surgical experience assessed each operation blindly and independently on DVD. The technological skills were assessed in the operating room. Results: One hundred operations were analyzed. Eight trainees and 10 consultant surgeons were recruited. No adverse events occurred due to technical or technological skills. Mean interrater reliability was kappa=0.88, P=technical and technological skills between trainee and consultant surgeons were significant, Mann-Whitney P=technical and technological skills can be measured to assess performance of laparoscopic surgeons. This technical and technological assessment tool for laparoscopic surgery seems to have face, content, concurrent, and construct validities and could be modified and applied to any laparoscopic operation. The tool has the possibility of being used in surgical training and appraisal. We aim to modify and apply this tool to advanced laparoscopic operations. PMID:17212881

  9. QuEST: Qualifying Environmentally Sustainable Technologies. Volume 2

    Science.gov (United States)

    Brown, Christina (Editor)

    2007-01-01

    TEERM focuses its validation efforts on technologies that have shown promise in laboratory testing, but lack testing under realistic or field environment. Mature technologies have advantages over those that are still in the developmental stage such as being more likely to be transitioned into a working environment. One way TEERM begins to evaluate the suitability of technologies is through Technology Readiness Levels (TRLs). TRLs are a systematic metric/measurement system that supports assessments of the maturity of a particular technology and the consistent comparison of maturity between different types of technology. TEERM generally works on demonstrating/validating alternatives that fall within TRLs 5-9. In instances where a mature technology does not exist for a particular Agency application, TEERM works with technology development groups and programs such as NASA's Innovative Partnerships Program (IPP). The IPP's purpose is to identify and document available technologies in light of NASA's needs, evaluate and prioritize those technologies, and reach out to find new partners. All TEERM projects involve multiple partners. Partnering reduces duplication of effort that otherwise might occur if individuals worked their problems alone. Partnering also helps reduce individual contributors' shares of the total cost of technology validation. Through collaboration and financial commitment from project stakeholders and third-party sources, it is possible to fully fund expensive demonstration/validation efforts.

  10. Design definition study of a lift/cruise fan technology V/STOL aircraft. Volume 2: Technology aircraft

    Science.gov (United States)

    1975-01-01

    Technology flight vehicles were defined for three different approaches which demonstrate the concept and characteristics of the multipurpose aircraft established for Navy missions. The propulsion system used for the various technology flight vehicles was representative of that established for the multipurpose aircraft. Existing J97-GE100 gas generators were selected based on cost, availability and exhaust characteristics. The LF459 fans were also selected and are compatible with both technology and operational vehicles. To comply with the design guideline safety criteria, it was determined that three gas generators were required to provide engine out safety in the hover flight mode. The final propulsion system established for the technology aircraft was three existing J97 gas generators powering three LF459 fans. Different aircraft candidates were evaluated for application to the three designated design approaches. Each configuration was evaluated on the basis of (1) propulsion system integration, (2) modification required, (3) pilot's visibility, (4) payload volume, and (5) adaptability to compatible location of center-of-gravity/aerodynamic center and thrust center.

  11. Legitimation problems of participatory processes in technology assessment and technology policy.

    Science.gov (United States)

    Saretzki, Thomas

    2012-11-01

    Since James Carroll (1971) made a strong case for "participatory technology", scientists, engineers, policy-makers and the public at large have seen quite a number of different approaches to design and implement participatory processes in technology assessment and technology policy. As these participatory experiments and practices spread over the last two decades, one could easily get the impression that participation turned from a theoretical normative claim to a working practice that goes without saying. Looking beyond the well-known forerunners and considering the ambivalent experiences that have been made under different conditions in various places, however, the "if" and "how" of participation are still contested issues when questions of technology are on the agenda. Legitimation problems indicate that attempts to justify participation in a given case have not been entirely successful in the eyes of relevant groups among the sponsors, participants, organizers or observers. Legitimation problems of participatory processes in technology assessment and technology policy vary considerably, and they do so not only with the two domains and the ways of their interrelation or the specific features of the participatory processes. If we ask whether or not participation is seen as problematic in technology assessment and technology policy-making and in what sense it is being evaluated as problematic, then we find that the answer depends also on the approaches and criteria that have been used to legitimize or delegitimize the call for a specific design of participation.

  12. The Past and the Future of Constructive Technology Assessment

    NARCIS (Netherlands)

    Schot, Johan; Rip, Arie

    1997-01-01

    Constructive technology assessment (CTA) is a member of the family of technology assessment approaches. developed in particular in the Netherlands and Denmark. CTA shifts the focus away from assessing impacts of new technologies to broadening design, development, and implementation processes.

  13. Definition of technology development missions for early Space Station satellite servicing. Volume 2: Technical

    Science.gov (United States)

    Cable, D. A.; Diewald, C. A.; Hills, T. C.; Parmentier, T. J.; Spencer, R. A.; Stone, G. E.

    1984-01-01

    Volume 2 contains the Technical Report of the approach and results of the Phase 2 study. The phase 2 servicing study was initiated in June 1983, and is being reported in this document. The scope of the contract was to: (1) define in detail five selected technology development missions (TDM); (2) conduct a design requirement analysis to refine definitions of satellite servicing requirements at the space station; and (3) develop a technology plan that would identify and schedule prerequisite precursor technology development, associated. STS flight experiments and space station experiments needed to provide onorbit validation of the evolving technology.

  14. Technology and the American Economy. Volume I.

    Science.gov (United States)

    National Commission on Technology, Automation and Economic Progress, Washington, DC.

    Public Law 88-444 asked the Commission to identify, assess, describe, and define aspects of technological change and to recommend specific legislative and administrative steps which should be taken by federal, state, and local governments. The Commission was to concern itself for 1 year with the coming decade. Their examination covered (1) The…

  15. Nuclear proliferation and civilian nuclear power: report of the Nonproliferation Alternative Systems Assessment Program. Volume 1. Program summary

    Energy Technology Data Exchange (ETDEWEB)

    1979-12-01

    This report summarizes the Nonproliferation Alternative Systems Assessment Program (NASAP): its background, its studies, and its results. This introductory chapter traces the growth of the issue of nuclear weapons proliferation and the organization and objectives of NASAP. Chapter 2 summarizes the program's assessments, findings and recommendations. Each of Volumes II-VII reports on an individual assessment (Volume II: Proliferation Resistance; Volume III: Resources and Fuel Cycle Facilities; Volume IV: Commercial Potential; Volume V: Economics and Systems Analysis; Volume VI: Safety and Environmental Considerations for Licensing; Volume VII: International Perspectives). Volume VIII (Advanced Concepts) presents a combined assessment of several less fully developed concepts, and Volume IX (Reactor and Fuel Cycle Descriptions) provides detailed descriptions of the reactor and fuel-cycle systems studied by NASAP.

  16. Nuclear proliferation and civilian nuclear power: report of the Nonproliferation Alternative Systems Assessment Program. Volume 1. Program summary

    International Nuclear Information System (INIS)

    1979-12-01

    This report summarizes the Nonproliferation Alternative Systems Assessment Program (NASAP): its background, its studies, and its results. This introductory chapter traces the growth of the issue of nuclear weapons proliferation and the organization and objectives of NASAP. Chapter 2 summarizes the program's assessments, findings and recommendations. Each of Volumes II-VII reports on an individual assessment (Volume II: Proliferation Resistance; Volume III: Resources and Fuel Cycle Facilities; Volume IV: Commercial Potential; Volume V: Economics and Systems Analysis; Volume VI: Safety and Environmental Considerations for Licensing; Volume VII: International Perspectives). Volume VIII (Advanced Concepts) presents a combined assessment of several less fully developed concepts, and Volume IX (Reactor and Fuel Cycle Descriptions) provides detailed descriptions of the reactor and fuel-cycle systems studied by NASAP

  17. Coal liquefaction: A research and development needs assessment: Final report, Volume II

    Energy Technology Data Exchange (ETDEWEB)

    Schindler, H.D.; Burke, F.P.; Chao, K.C.; Davis, B.H.; Gorbaty, M.L.; Klier, K.; Kruse, C.W.; Larsen, J.W.; Lumpkin, R.E.; McIlwain, M.E.; Wender, I.; Stewart, N.

    1989-03-01

    Volume II of this report on an assessment of research needs for coal liquefaction contains reviews of the five liquefaction technologies---direct, indirect, pyrolysis, coprocessing, and bioconversion. These reviews are not meant to be encyclopedic; several outstanding reviews of liquefaction have appeared in recent years and the reader is referred to these whenever applicable. Instead, these chapters contain reviews of selected topics that serve to support the panel's recommendations or to illustrate recent accomplishments, work in progress, or areas of major research interest. At the beginning of each of these chapters is a brief introduction and a summary of the most important research recommendations brought out during the panel discussions and supported by the material presented in the review. A review of liquefaction developments outside the US is included. 594 refs., 100 figs., 60 tabs.

  18. US long distance fiber optic networks: Technology, evolution and advanced concepts. Volume 3: Advanced networks and economics

    Science.gov (United States)

    1986-10-01

    This study projects until 2000 the evolution of long distance fiber optic networks in the U.S. Volume 1 is the executive Summary. Volume 2 focuses on fiber optic components and systems that are directly related to the operation of long-haul networks. Optimistic, pessimistic and most likely scenarios of technology development are presented. The activities of national and regional companies implementing fiber long haul networks are also highlighted, along with an analysis of the market and regulatory forces affecting network evolution. Volume 3 presents advanced fiber optic network concept definitions. Inter-LATA traffic is quantified and forms the basis for the construction of 11-, 15-, 17-, and 23-node networks. Using the technology projections from Volume 2, a financial model identifies cost drivers and determines circuit mile costs between any two LATAs. A comparison of fiber optics with alternative transmission concludes the report.

  19. SU-E-J-79: Internal Tumor Volume Motion and Volume Size Assessment Using 4D CT Lung Data

    Energy Technology Data Exchange (ETDEWEB)

    Jurkovic, I [University of Texas Health Science Center at San Antonio, San Antonio, TX (United States); Stathakis, S; Li, Y; Patel, A; Vincent, J; Papanikolaou, N; Mavroidis, P [Cancer Therapy and Research Center University of Texas Health Sciences Center at San Antonio, San Antonio, TX (United States)

    2014-06-01

    Purpose: To assess internal tumor volume change through breathing cycle and associated tumor motion using the 4DCT data. Methods: Respiration induced volume change through breathing cycle and associated motion was analyzed for nine patients that were scanned during the different respiratory phases. The examined datasets were the maximum and average intensity projections (MIP and AIP) and the 10 phases of the respiratory cycle. The internal target volume (ITV) was delineated on each of the phases and the planning target volume (PTV) was then created by adding setup margins to the ITV. Tumor motion through the phases was assessed using the acquired 4DCT dataset, which was then used to determine if the margins used for the ITV creation successfully encompassed the tumor in three dimensions. Results: Results showed that GTV motion along the superior inferior axes was the largest in all the cases independent of the tumor location and/or size or the use of abdomen compression. The extent of the tumor motion was found to be connected with the size of the GTV. The smallest GTVs exhibited largest motion vector independent of the tumor location. The motion vector size varied through the phases depending on the tumor size and location and it was smallest for phases 20 and 30. The smaller the volume of the delineated GTV, the greater its volume difference through the different respiratory phases was. The average GTV volume change was largest for the phases 60 and 70. Conclusion: Even if GTV is delineated using both AIP and MIP datasets, its motion extent will exceed the used margins especially for the very small GTV volumes. When the GTV size is less than 10 cc it is recommended to use fusion of the GTVs through all the phases to create the planning ITV.

  20. Oil and gas technology transfer activities and potential in eight major producing states. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    1993-07-01

    In 1990, the Interstate Oil and Gas Compact Commission (the Compact) performed a study that identified the structure and deficiencies of the system by which oil and gas producers receive information about the potential of new technologies and communicate their problems and technology needs back to the research community. The conclusions of that work were that major integrated companies have significantly more and better sources of technology information than independent producers. The majors also have significantly better mechanisms for communicating problems to the research and development (R&D) community. As a consequence, the Compact recommended analyzing potential mechanisms to improve technology transfer channels for independents and to accelerate independents acceptance and use of existing and emerging technologies. Building on this work, the Compact, with a grant from the US Department Energy, has reviewed specific technology transfer organizations in each of eight major oil producing states to identify specific R&D and technology transfer organizations, characterize their existing activities, and identify potential future activities that could be performed to enhance technology transfer to oil and gas producers. The profiles were developed based on information received from organizations,follow-up interviews, site visit and conversations, and participation in their sponsored technology transfer activities. The results of this effort are reported in this volume. In addition, the Compact has also developed a framework for the development of evaluation methodologies to determine the effectiveness of technology transfer programs in performing their intended functions and in achieving desired impacts impacts in the producing community. The results of that work are provided in a separate volume.

  1. Accuracy of renal volume assessment in children by three-dimensional sonography

    International Nuclear Information System (INIS)

    Fritz, G.A.; Riccabona, M.; Bohdal, G.; Quehenberger, F.

    2003-01-01

    Purpose: Prospective evaluation of the accuracy of three-dimensional ultrasound (3DUS) to assess the renal parenchymal volume. Materials and Methods: CT, MRI, 2DUS and 3DUS were used to measure the renal volume in 40 patients (range: neonate to 17 years; mean age: 8.95 years). The 3DUS was determined with a Voluson 730 (Kretztechnik, GE) or an external 3D-system (EchoTech, GE) using electromagnetic positioning sensors attached to conventional 2DUS-equipment. The 2DUS volume was calculated with the ellipsoid equation and the 3DUS volume computed with the system integrated software. For CT and MRI, planimetric analysis was used to determine the renal parenchymal volume, whereby the dilated collecting system of a hydronephrosis was subtracted to obtain the real renal parenchymal volume. The results of 2DUS and 3DUS were compared to the results of CT and MRI, and inter- and intraobserver variabilities were calculated. Results: In 74 of 77 kidneys, the 3DUS study was of diagnostic quality. The accuracy of the 3DUS volumes compared well to the CT and MRI volumes with a mean difference of -1.8 ± 4.6% versus a mean difference of -2.4 ± 15.4% for 2DUS. In normal kidneys, the accuracy was -2.6 ± 4.4% for 3DUS and -3.8 ± 14.7% for 2DUS. In hydronephrosis, the accuracy was +4.0 ± 5.9% and +9.6 ± 21.3%, respectively, indicating that 3DUS is more accurate than 2DUS, particularly in kidneys with a dilated collecting system. Inter- and intraobserver variabilities were ± 7.3% and ± 5.3%. Conclusion: For assessing the renal parenchymal volume in children, 3DUS is feasible and comparable to CT and MRI. (orig.) [de

  2. Nuclear proliferation and civilian nuclear power. Report of the Nonproliferation Alternative Systems Assessment Program. Volume I. Program summary

    International Nuclear Information System (INIS)

    1980-06-01

    This report summarizes the Nonproliferation Alternative Systems Assessment Program (NASAP): its background, its studies, and its results. The introductory chapter traces the growth of the issue of nuclear weapons proliferation and the organization and objectives of NASAP. Chapter 2 summarizes the program's assessments, findings, and recommendations. Each of Volumes II-VII reports on an individual assessment (Volumn II: Proliferation Resistance; Volume III: Resources and Fuel Cycle Facilities; Volume IV: Commercial Potential; Volume V: Economics and Systems Analysis; Volume VI: Safety and Environmental Considerations for Licensing; Volume VII: International Perspectives). Volume VIII (Advanced Concepts) presents a combined assessment of several less fully developed concepts, and Volume IX (Reactor and Fuel Cycle Descriptions) provides detailed descriptions of the reactor and fuel-cycle systems studied by NASAP

  3. Technology assessments in transportation: survey of recent literature

    Energy Technology Data Exchange (ETDEWEB)

    LaBelle, S.J.

    1980-03-01

    A survey and an evaluation of recent studies of transportation systems done in a technology-assessment framework were undertaken as the basis for a detailed statement of work for a US Department of Energy technology assessment of transportation energy-conservation strategies. Several bibliographies were searched and numerous professionals in the field of technology assessment were contacted regarding current work. Detailed abstracts were prepared for studies judged to be sufficiently broad in coverage of impacts assessed, yet detailed in coverage of all or part of the nation's transportation systems. Some studies were rich in data but not comprehensive in their analytical approach; brief abstracts were prepared for these. An explanation of the criteria used to screen the studies, as well as abstracts of 37 reports, are provided in this compendium of transportation-technology-assessment literature.

  4. TECHNOLOGY MANAGEMENT PROCESS FRAMEWORK

    Directory of Open Access Journals (Sweden)

    Ikura Yamamoto

    2012-02-01

    Full Text Available The effective management of technology as a source of competitive advantage is of vital importance for many organizations. It is necessary to understand, communicate and integrate technology strategy with marketing, financial, operations and human resource strategies. This is of particular importance when one considers the increasing cost, pace and complexity of technology developments, combined with shortening product life cycles. A five process model provides a framework within which technology management activities can be understood: identification, selection, acquisition, exploitation and protection. Based on this model, a technology management assessment procedure has been developed, using an ``action research’’ approach. This paper presents an industrial case study describing the first full application of the procedure within a high-volume manufacturing business. The impact of applying the procedure is assessed in terms of benefits to the participating business, together with improvements to the assessment procedure itself, in the context of the action research framework. Keyword: Technology, Strategy, Management, Assessment

  5. 10. National Nuclear Science and Technologies Congress Proceedings Full Texts Volume 1

    International Nuclear Information System (INIS)

    2009-01-01

    X. National Nuclear Science and Technologies Congress was held on 6-9 October 2009 in Mugla, Turkey in the course of collaborative organization undertaken by Turkish Atomic Energy Authority, Mugla University and Sitki Kocman Foundation. This first volume of Proceedings Book contains 75 submitted presentations and 36 of them are full texts on applications of nuclear techniques.

  6. Second interim assessment of the Canadian concept for nuclear fuel waste disposal. Volume 1

    International Nuclear Information System (INIS)

    Wuschke, D.M.; Gillespie, P.A.; Main, D.E.

    1985-07-01

    The nuclear fuel waste disposal concept chosen for development and assessment in Canada involves the isolation of corrosion-resistant containers of waste in a vault located deep in plutonic rock. As the concept and the assessment tools are developed, periodic assessments are performed to permit evaluation of the methodology and provide feedback to those developing the concept. The ultimate goal of these assessments is to predict what impact the disposal system would have on man and the environment if the concept were implemented. The second assessment was performed in 1984 and is documented in the Second Interim assessment of the Canadian Concept for Nuclear Fuel Waste Disposal Volumes 1 to 4. This volume, entitled Summary, is a condensation of Volumes 2, 3 and 4. It briefly describes the Canadian nuclear fuel waste disposal concept, and the methods and results of the second interim pre-closure and post-closure assessments of that concept. 46 refs

  7. Electric and Magnetic Fields (EMF) RAPID Program Engineering Project 8: FINAL REPORT, Evaluation of Field Reduction Technologies, Volume 1 (Report) and Volume 2 (Appendices)

    Energy Technology Data Exchange (ETDEWEB)

    Commonwealth Associates, Inc.; IIT Research Institute

    1997-08-01

    This draft report consists of two volumes. Volume 1, the main body, contains an introducto~ sectionj an overview of magnetic fields sectio~ and field reduction technology evaluation section. Magnetic field reduction methods are evalpated for transmission lines, distribution Iines,sulxtations, building wiring applkmd machinery, and transportation systems. The evaluation considers effectiveness, co% and other ftiors. Volume 2 contains five appendices, Append~ A presents magnetic field shielding information. Appendices B and C present design assumptions and magnetic field plots for transmission and distribution lines, respectively. Appendices D and E present cost estimate details for transmission and distribution limes, respectively.

  8. Spent Nuclear Fuel Alternative Technology Risk Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Perella, V.F.

    1999-11-29

    A Research Reactor Spent Nuclear Fuel Task Team (RRTT) was chartered by the Department of Energy (DOE) Office of Spent Fuel Management with the responsibility to recommend a course of action leading to a final technology selection for the interim management and ultimate disposition of the foreign and domestic aluminum-based research reactor spent nuclear fuel (SNF) under DOE''s jurisdiction. The RRTT evaluated eleven potential SNF management technologies and recommended that two technologies, direct co-disposal and an isotopic dilution alternative, either press and dilute or melt and dilute, be developed in parallel. Based upon that recommendation, the Westinghouse Savannah River Company (WSRC) organized the SNF Alternative Technology Program to further develop the direct co-disposal and melt and dilute technologies and provide a WSRC recommendation to DOE for a preferred SNF alternative management technology. A technology risk assessment was conducted as a first step in this recommendation process to determine if either, or both, of the technologies posed significant risks that would make them unsuitable for further development. This report provides the results of that technology risk assessment.

  9. Spent Nuclear Fuel Alternative Technology Risk Assessment

    International Nuclear Information System (INIS)

    Perella, V.F.

    1999-01-01

    A Research Reactor Spent Nuclear Fuel Task Team (RRTT) was chartered by the Department of Energy (DOE) Office of Spent Fuel Management with the responsibility to recommend a course of action leading to a final technology selection for the interim management and ultimate disposition of the foreign and domestic aluminum-based research reactor spent nuclear fuel (SNF) under DOE''s jurisdiction. The RRTT evaluated eleven potential SNF management technologies and recommended that two technologies, direct co-disposal and an isotopic dilution alternative, either press and dilute or melt and dilute, be developed in parallel. Based upon that recommendation, the Westinghouse Savannah River Company (WSRC) organized the SNF Alternative Technology Program to further develop the direct co-disposal and melt and dilute technologies and provide a WSRC recommendation to DOE for a preferred SNF alternative management technology. A technology risk assessment was conducted as a first step in this recommendation process to determine if either, or both, of the technologies posed significant risks that would make them unsuitable for further development. This report provides the results of that technology risk assessment

  10. Lobar analysis of collapsibility indices to assess functional lung volumes in COPD patients.

    Science.gov (United States)

    Kitano, Mariko; Iwano, Shingo; Hashimoto, Naozumi; Matsuo, Keiji; Hasegawa, Yoshinori; Naganawa, Shinji

    2014-01-01

    We investigated correlations between lung volume collapsibility indices and pulmonary function test (PFT) results and assessed lobar differences in chronic obstructive pulmonary disease (COPD) patients, using paired inspiratory and expiratory three dimensional (3D) computed tomography (CT) images. We retrospectively assessed 28 COPD patients who underwent paired inspiratory and expiratory CT and PFT exams on the same day. A computer-aided diagnostic system calculated total lobar volume and emphysematous lobar volume (ELV). Normal lobar volume (NLV) was determined by subtracting ELV from total lobar volume, both for inspiratory phase (NLVI) and for expiratory phase (NLVE). We also determined lobar collapsibility indices: NLV collapsibility ratio (NLVCR) (%)=(1-NLVE/NLVI)×100%. Associations between lobar volumes and PFT results, and collapsibility indices and PFT results were determined by Pearson correlation analysis. NLVCR values were significantly correlated with PFT results. Forced expiratory volume in 1 second, measured as percent of predicted results (FEV1%P) was significantly correlated with NLVCR values for the lower lobes (Pvolume, measured as percent of predicted (DLCO/VA%P) results were strongly correlated with ELVI for the upper lobes (Ppulmonary function in COPD patients.

  11. Fluid Vessel Quantity using Non-Invasive PZT Technology Flight Volume Measurements Under Zero G Analysis

    Science.gov (United States)

    Garofalo, Anthony A.

    2013-01-01

    The purpose of the project is to perform analysis of data using the Systems Engineering Educational Discovery (SEED) program data from 2011 and 2012 Fluid Vessel Quantity using Non-Invasive PZT Technology flight volume measurements under Zero G conditions (parabolic Plane flight data). Also experimental planning and lab work for future sub-orbital experiments to use the NASA PZT technology for fluid volume measurement. Along with conducting data analysis of flight data, I also did a variety of other tasks. I provided the lab with detailed technical drawings, experimented with 3d printers, made changes to the liquid nitrogen skid schematics, and learned how to weld. I also programmed microcontrollers to interact with various sensors and helped with other things going on around the lab.

  12. Space-reactor electric systems: subsystem technology assessment

    International Nuclear Information System (INIS)

    Anderson, R.V.; Bost, D.; Determan, W.R.

    1983-01-01

    This report documents the subsystem technology assessment. For the purpose of this report, five subsystems were defined for a space reactor electric system, and the report is organized around these subsystems: reactor; shielding; primary heat transport; power conversion and processing; and heat rejection. The purpose of the assessment was to determine the current technology status and the technology potentials for different types of the five subsystems. The cost and schedule needed to develop these potentials were estimated, and sets of development-compatible subsystems were identified

  13. Western oil shale development: a technology assessment. Volume 1. Main report

    Energy Technology Data Exchange (ETDEWEB)

    1981-11-01

    The general goal of this study is to present the prospects of shale oil within the context of (1) environmental constraints, (2) available natural and economic resources, and (3) the characteristics of existing and emerging technology. The objectives are: to review shale oil technologies objectively as a means of supplying domestically produced fuels within environmental, social, economic, and legal/institutional constraints; using available data, analyses, and experienced judgment, to examine the major points of uncertainty regarding potential impacts of oil shale development; to resolve issues where data and analyses are compelling or where conclusions can be reached on judgmental grounds; to specify issues which cannot be resolved on the bases of the data, analyses, and experienced judgment currently available; and when appropriate and feasible, to suggest ways for the removal of existing uncertainties that stand in the way of resolving outstanding issues.

  14. Advancing automation and robotics technology for the Space Station and for the US economy, volume 2

    Science.gov (United States)

    1985-01-01

    In response to Public Law 98-371, dated July 18, 1984, the NASA Advanced Technology Advisory Committee has studied automation and robotics for use in the Space Station. The Technical Report, Volume 2, provides background information on automation and robotics technologies and their potential and documents: the relevant aspects of Space Station design; representative examples of automation and robotics; applications; the state of the technology and advances needed; and considerations for technology transfer to U.S. industry and for space commercialization.

  15. Fiscal 1975 Sunshine Project research report. Technology assessment on hydrogen energy technology. Part 2; 1975 nendo suiso energy gijutsu no technology assessment seika hokokuksho. 2

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1976-03-31

    This research assesses the impact of development of practical hydrogen energy technology on the economy, society and environment in Japan, and proposes some effective countermeasures, the required technical development target and a promising promotion system. The example of technology assessment assuming practical technology several tens years after is hardly found. Hydrogen energy technology is in the first stage among (1) initial planning stage, (2) technical research and development stage, (3) practical technology stage and (4) service operation stage. In the first fiscal year, as the first stage of determination of the communication route between society and technology, study was made on the concrete system image of practical technology. In this fiscal year, study was made entirely on preparation of the scenario for imaging the future economy and society concretely, modifying the planning of the hydrogen energy system. Through comparison of the scenario and system, the meaning and problem of the hydrogen energy technology were clarified. (NEDO)

  16. Third international spent fuel storage technology symposium/workshop: proceedings. Volume 2

    International Nuclear Information System (INIS)

    1986-01-01

    The scope of this meeting comprised dry storage and rod consolidation, emphasizing programs on water reactor fuel with zirconium alloy cladding. Volume 2 contains the papers from the poster session and workshops that were conducted during the meeting. There were 18 poster presentations. Four workshops were held: Fuel Integrity; Storage System Modeling and Analysis; Rod Consolidation Technology; and System Integration and Optimization. Individual papers were processed for inclusion in the Energy Data Base

  17. Third international spent fuel stroage technology symposium/workshop: proceedings. Volume 1

    International Nuclear Information System (INIS)

    1986-01-01

    The scope of this meeting comprised dry storage and rod consolidation, emphasizing programs on water reactor fuel with zirconium alloy cladding. Volume 1 contains the symposium papers, together with the question/answer sessions that followed the presentations. Four sessions were held: Dry Storage System Tests, Demonstrations and Analyses; At-Reactor and Central Storage Facilities; Dry Storage Integrity; and Rod Consolidation Technology and Demonstrations. Individual papers were processed for inclusion in the Energy Data Base

  18. Predicting technology operational availability using technical maturity assessment

    International Nuclear Information System (INIS)

    Kenley, C.R.; Creque, T.R.

    1998-01-01

    A technical maturity assessment method was performed by systems engineers in collaboration with an advisory panel composed of team members from different Department of Energy sites and from different engineering and science disciplines. Various stabilization technologies were assessed annually as to their relative maturity and availability for use in stabilizing nuclear materials. After three years of assessments, several of the technologies are now components of operational systems. A regression analysis of the historical assessments was performed, and it was concluded that the numerical technical maturity score produced by a team of experts can provide a powerful predictor of the time remaining until the operational application of technologies

  19. Viability Assessment of a Repository at Yucca Mountain. Volume 1: Introduction and Site Characteristics

    Energy Technology Data Exchange (ETDEWEB)

    None

    1998-12-01

    This first volume contains an introduction to the viability assessment, including the purpose, scope, waste forms, technical challenges, an historical perspective, regulatory framework, management of the repository, technical components, preparations for the license application, and repository milestones after the assessment. The second part of this first volume addresses characteristics of the Yucca Mountain site.

  20. The contribution of health technology assessment, health needs assessment, and health impact assessment to the assessment and translation of technologies in the field of public health genomics.

    Science.gov (United States)

    Rosenkötter, N; Vondeling, H; Blancquaert, I; Mekel, O C L; Kristensen, F B; Brand, A

    2011-01-01

    The European Union has named genomics as one of the promising research fields for the development of new health technologies. Major concerns with regard to these fields are, on the one hand, the rather slow and limited translation of new knowledge and, on the other hand, missing insights into the impact on public health and health care practice of those technologies that are actually introduced. This paper aims to give an overview of the major assessment instruments in public health [health technology assessment (HTA), health needs assessment (HNA) and health impact assessment (HIA)] which could contribute to the systematic translation and assessment of genomic health applications by focussing at population level and on public health policy making. It is shown to what extent HTA, HNA and HIA contribute to translational research by using the continuum of translational research (T1-T4) in genomic medicine as an analytic framework. The selected assessment methodologies predominantly cover 2 to 4 phases within the T1-T4 system. HTA delivers the most complete set of methodologies when assessing health applications. HNA can be used to prioritize areas where genomic health applications are needed or to identify infrastructural needs. HIA delivers information on the impact of technologies in a wider scope and promotes informed decision making. HTA, HNA and HIA provide a partly overlapping and partly unique set of methodologies and infrastructure for the translation and assessment of genomic health applications. They are broad in scope and go beyond the continuum of T1-T4 translational research regarding policy translation. Copyright © 2010 S. Karger AG, Basel.

  1. Support technologies to cater for rockbursts and falls of ground in the immediate face area, volume 1.

    CSIR Research Space (South Africa)

    Daehnk, A

    2000-03-01

    Full Text Available Final Project Report Support technologies to cater for rockbursts and falls of ground in the immediate face area Volume I A. Daehnke, E. Acheampong, N. Reddy, K.B. Le Bron and A.T. Haile Research agency: CSIR Mining Technology Project number: GAP...

  2. The Contribution of Health Technology Assessment, Health Needs Assessment, and Health Impact Assessment to the Assessment and Translation of Technologies in the Field of Public Health Genomics

    DEFF Research Database (Denmark)

    Rosenkotter, N.; Vondeling, H.; Blancquaert, I.

    2011-01-01

    contribute to the systematic translation and assessment of genomic health applications by focussing at population level and on public health policy making. It is shown to what extent HTA, HNA and HIA contribute to translational research by using the continuum of translational research (T1-T4) in genomic...... into the impact on public health and health care practice of those technologies that are actually introduced. This paper aims to give an overview of the major assessment instruments in public health [ health technology assessment (HTA), health needs assessment (HNA) and health impact assessment (HIA)] which could...... medicine as an analytic framework. The selected assessment methodologies predominantly cover 2 to 4 phases within the T1-T4 system. HTA delivers the most complete set of methodologies when assessing health applications. HNA can be used to prioritize areas where genomic health applications are needed...

  3. Technology assessment and social science research on technology

    International Nuclear Information System (INIS)

    Thienen, V. von

    1983-01-01

    In a first step this bibliography wants to overcome the want of systematic scientific data compilations and evaluations of experiences in studies on technology assessment. It concentrates on the social and political aspects of the development of technologies and the decision on their utilization by presenting titles which have been published in English- and German-speaking countries in the past decade. The bibliography is divided into various chapters and subchapters. The index part contains authors' indexes and publishers' indexes, subject indexes, other bibliographies and selected periodicals. (orig.) With 1647 refs [de

  4. 5. annual clean coal technology conference: powering the next millennium. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-06-01

    The Fifth Annual Clean Coal Technology Conference focuses on presenting strategies and approaches that will enable clean coal technologies to resolve the competing, interrelated demands for power, economic viability, and environmental constraints associated with the use of coal in the post-2000 era. The program addresses the dynamic changes that will result from utility competition and industry restructuring, and to the evolution of markets abroad. Current projections for electricity highlight the preferential role that electric power will have in accomplishing the long-range goals of most nations. Increase demands can be met by utilizing coal in technologies that achieve environmental goals while keeping the cost- per-unit of energy competitive. Results from projects in the DOE Clean Coal Technology Demonstration Program confirm that technology is the pathway to achieving these goals. The industry/government partnership, cemented over the past 10 years, is focused on moving the clean coal technologies into the domestic and international marketplaces. The Fifth Annual Clean Coal Technology Conference provides a forum to discuss these benchmark issues and the essential role and need for these technologies in the post-2000 era. This volume contains technical papers on: advanced coal process systems; advanced industrial systems; advanced cleanup systems; and advanced power generation systems. In addition, there are poster session abstracts. Selected papers from this proceedings have been processed for inclusion in the Energy Science and Technology database.

  5. Technologies for Language Assessment.

    Science.gov (United States)

    Burstein, Jill; And Others

    1996-01-01

    Reviews current and developing technology uses that are relevant to language assessment and discusses examples of recent linguistic applications from the laboratory at the Educational Testing Service. The processes of language test development are described and the functions they serve from the perspective of a large testing organization are…

  6. Fifth DOE symposium on enhanced oil and gas recovery and improved drilling technology. Volume 2. Oil

    Energy Technology Data Exchange (ETDEWEB)

    Linville, B. [ed.

    1979-01-01

    Volume 2 contains papers from the following sessions: residual oil determination; thermal methods; heavy oil-tar sands; technology transfer; and carbon dioxide flooding. Individual papers were processed.

  7. Swedish Technology Teachers' Views on Assessing Student Understandings of Technological Systems

    Science.gov (United States)

    Schooner, Patrick; Klasander, Claes; Hallström, Jonas

    2018-01-01

    Technology education is a new school subject in comparison with other subjects within the Swedish compulsory school system. Research in technology education shows that technology teachers lack experience of and support for assessment in comparison with the long-term experiences that other teachers use in their subjects. This becomes especially…

  8. Sustainability assessment of advanced wastewater treatment technologies

    DEFF Research Database (Denmark)

    Høibye, Linda; Clauson-Kaas, Jes; Wenzel, Henrik

    2007-01-01

    , which includes technical, economic and environmental aspects. The technical and economic assessment is performed on 5 advanced treatment technologies: sand filtration, ozone treatment, UV exclusively for disinfection of pathogenic microorganisms, Membrane Bioreactor (MBR), and UV in combination......As a consequence of the EU Water Framwork Directive, more focus is now on discharges of hazardous substances from wastewater treatment plants and sewers. Thus, many municipalities in Denmark may have to adopt to future advenced treatment technologies. This paper describes a holistic assessment...... with advanced oxidation. The technical assessment is based on 12 hazardous substances comprising heavy metals, organic pollutants, endocrine disruptors as well as pathogenic microorganisms. The environmental assessment is performed by life cycle assessment (LCA) comprising 9 of the specific hazardous substances...

  9. Sustainability assessment of advanced wastewater treatment technologies

    DEFF Research Database (Denmark)

    Høibye, Linda; Clauson-Kaas, Jes; Wenzel, Henrik

    2008-01-01

    , which includes technical, economical and environmental aspects. The technical and economical assessment is performed on 5 advanced treatment technologies: sand filtration, ozone treatment, UV exclusively for disinfection of pathogenic microorganisms, membrane bioreactor (MBR) and UV in combination......As a consequence of the EU Water Framework Directive more focus is now on discharges of hazardous substances from wastewater treatment plants and sewers. Thus, many municipalities in Denmark may have to adopt to future advanced treatment technologies. This paper describes a holistic assessment...... with advanced oxidation. The technical assessment is based on 12 hazardous substances comprising heavy metals, organic pollutants, endocrine disruptors as well as pathogenic microorganisms. The environmental assessment is performed by life cycle assessment (LCA) comprising 9 of the specific hazardous substances...

  10. Improving tag/seal technologies: the vulnerability assessment component

    International Nuclear Information System (INIS)

    Jones, J.L.

    1996-01-01

    The Department of Energy (DOE), specifically the Office of Nonproliferation and National Security, has sponsored the development of numerous tag and seal technologies for high-security/high-valued applications. One important component in this technology development effort has been the continuous integration of vulnerability assessments. The Idaho National Engineering Laboratory (INEL) has been the lead laboratory for vulnerability assessments of fiber-optic-based tag/seal technologies. This paper presents a brief historical overview and the current status of the DOE high-security tag/seal development program and discusses INEL's adversarial role and assessment philosophy. Verification testing criteria used to define ''successful'' tampering attempts/attacks are discussed. Finally, the advantages of integrating a vulnerability assessment into the development of commercial security tag/seals are presented

  11. Statistical assessment of the learning curves of health technologies.

    Science.gov (United States)

    Ramsay, C R; Grant, A M; Wallace, S A; Garthwaite, P H; Monk, A F; Russell, I T

    2001-01-01

    (1) To describe systematically studies that directly assessed the learning curve effect of health technologies. (2) Systematically to identify 'novel' statistical techniques applied to learning curve data in other fields, such as psychology and manufacturing. (3) To test these statistical techniques in data sets from studies of varying designs to assess health technologies in which learning curve effects are known to exist. METHODS - STUDY SELECTION (HEALTH TECHNOLOGY ASSESSMENT LITERATURE REVIEW): For a study to be included, it had to include a formal analysis of the learning curve of a health technology using a graphical, tabular or statistical technique. METHODS - STUDY SELECTION (NON-HEALTH TECHNOLOGY ASSESSMENT LITERATURE SEARCH): For a study to be included, it had to include a formal assessment of a learning curve using a statistical technique that had not been identified in the previous search. METHODS - DATA SOURCES: Six clinical and 16 non-clinical biomedical databases were searched. A limited amount of handsearching and scanning of reference lists was also undertaken. METHODS - DATA EXTRACTION (HEALTH TECHNOLOGY ASSESSMENT LITERATURE REVIEW): A number of study characteristics were abstracted from the papers such as study design, study size, number of operators and the statistical method used. METHODS - DATA EXTRACTION (NON-HEALTH TECHNOLOGY ASSESSMENT LITERATURE SEARCH): The new statistical techniques identified were categorised into four subgroups of increasing complexity: exploratory data analysis; simple series data analysis; complex data structure analysis, generic techniques. METHODS - TESTING OF STATISTICAL METHODS: Some of the statistical methods identified in the systematic searches for single (simple) operator series data and for multiple (complex) operator series data were illustrated and explored using three data sets. The first was a case series of 190 consecutive laparoscopic fundoplication procedures performed by a single surgeon; the second

  12. Ovarian volume and antral follicle count assessed by MRI and transvaginal ultrasonography: a methodological study.

    Science.gov (United States)

    Leonhardt, Henrik; Gull, Berit; Stener-Victorin, Elisabet; Hellström, Mikael

    2014-03-01

    Ultrasonographic measurements of ovarian volume and antral follicle count are of clinical importance as diagnostic features of polycystic ovarian syndrome (PCOS), and as a parameter in estimation of ovarian follicular reserve in infertility care. To compare two-dimensional (2D)/three-dimensional (3D) transvaginal ultrasonography (TVUS) and magnetic resonance imaging (MRI) for estimation of ovarian volume and antral follicle count, and to assess reproducibility and inter-observer agreement of MRI measurements. Volumes of 172 ovaries in 99 women aged 21-37 years were calculated (length x width x height x 0.523) with conventional 2D TVUS and 2D MRI. Semi-automatic estimates of ovarian volumes were obtained by 3D MRI. Antral follicles were counted manually on 2D MRI and automatically by 3D TVUS (SonoAVC), and stratified according to follicle size. Mean ovarian volume assessed by 2D TVUS (13.1 ± 6.4 mL) was larger than assessed by 2D MRI (9.6 ± 4.1) and 3D MRI (11.4 ± 4.5) (P 0.77. 2D MRI reveals more antral follicles, especially of small size, than 3D TVUS. Ovarian volume estimation by MRI provides smaller volumes than by the reference standard 2D TVUS. Ovarian volume estimation by 3D MRI, allowing independence of non-ellipsoid ovarian shape measurement errors, provides volumes closer to 2D TVUS values than does 2D MRI. Reproducibility and inter-observer agreement of 2D MRI measurements of ovarian volume and total follicle count are good.

  13. Sustaining Innovation: Developing an Instructional Technology Assessment Process

    Science.gov (United States)

    Carmo, Monica Cristina

    2013-01-01

    This case study developed an instructional technology assessment process for the Gevirtz Graduate School of Education (GGSE). The theoretical framework of Adelman and Taylor (2001) guided the development of this instructional technology assessment process and the tools to aid in its facilitation. GGSE faculty, staff, and graduate students…

  14. Radioactive waste package assay facility. Volume 1. Application of assay technology

    International Nuclear Information System (INIS)

    Findlay, D.J.S.; Green, T.H.; Molesworth, T.V.; Staniforth, D.; Strachan, N.R.; Rogers, J.D.; Wise, M.O.; Forrest, K.R.

    1992-01-01

    This report, in three volumes, covers the work carried out by Taylor Woodrow Construction Ltd., and two major sub-contractors: Harwell Laboratory (AEA Technology) and Siemens Plessey Controls Ltd., on the development of a radioactive waste package assay facility, for cemented 500 litre intermediate level waste drums. In volume 1, the reasons for assay are considered together with the various techniques that can be used, and the information that can be obtained. The practical problems associated with the use of the various techniques in an integrated assay facility are identified, and the key parameters defined. Engineering and operational features are examined and provisional designs proposed for facilities at three throughput levels: 15,000, 750 and 30 drums per year respectively. The capital and operating costs for such facilities have been estimated. A number of recommendations are made for further work. 16 refs., 14 figs., 13 tabs

  15. X-ray volume imaging in bladder radiotherapy verification

    International Nuclear Information System (INIS)

    Henry, Ann M.; Stratford, Julia; McCarthy, Claire; Davies, Julie; Sykes, Jonathan R.; Amer, Ali; Marchant, Tom; Cowan, Richard; Wylie, James; Logue, John; Livsey, Jacqueline; Khoo, Vincent S.; Moore, Chris; Price, Pat

    2006-01-01

    Purpose: To assess the clinical utility of X-ray volume imaging (XVI) for verification of bladder radiotherapy and to quantify geometric error in bladder radiotherapy delivery. Methods and Materials: Twenty subjects undergoing conformal bladder radiotherapy were recruited. X-ray volume images and electronic portal images (EPIs) were acquired for the first 5 fractions and then once weekly. X-ray volume images were co-registered with the planning computed tomography scan and clinical target volume coverage assessed in three dimensions (3D). Interfraction bladder volume change was described by quantifying changes in bladder volume with time. Bony setup errors were compared from both XVI and EPI. Results: The bladder boundary was clearly visible on coronal XVI views in nearly all images, allowing accurate 3D treatment verification. In 93.5% of imaged fractions, the clinical target volume was within the planning target volume. Most subjects displayed consistent bladder volumes, but 25% displayed changes that could be predicted from the first three XVIs. Bony setup errors were similar whether calculated from XVI or EPI. Conclusions: Coronal XVI can be used to verify 3D bladder radiotherapy delivery. Image-guided interventions to reduce geographic miss and normal tissue toxicity are feasible with this technology

  16. Guidance on the Technology Performance Level (TPL) Assessment Methodology

    Energy Technology Data Exchange (ETDEWEB)

    Weber, Jochem [National Renewable Energy Lab. (NREL), Golden, CO (United States); Roberts, Jesse D. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Babarit, Aurelien [Ecole Centrale de Nantes (France). Lab. of Research in Hydrodynamics, Energetics and Atmospheric Environment (LHEEA); Costello, Ronan [Wave Venture, Penstraze (United Kingdom); Bull, Diana L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Neilson, Kim [Ramboll, Copenhagen (Denmark); Bittencourt, Claudio [DNV GL, London (United Kingdom); Kennedy, Ben [Wave Venture, Penstraze (United Kingdom); Malins, Robert Joseph [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Dykes, Katherine [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-09-01

    This document presents the revised Technology Performance Level (TPL) assessment methodology. There are three parts to this revised methodology 1) the Stakeholder Needs and Assessment Guidance (this document), 2) the Technical Submission form, 3) the TPL scoring spreadsheet. The TPL assessment is designed to give a technology neutral or agnostic assessment of any wave energy converter technology. The focus of the TPL is on the performance of the technology in meeting the customer’s needs. The original TPL is described in [1, 2] and those references also detail the critical differences in the nature of the TPL when compared to the more widely used technology readiness level (TRL). (Wave energy TRL is described in [3]). The revised TPL is particularly intended to be useful to investors and also to assist technology developers to conduct comprehensive assessments in a way that is meaningful and attractive to investors. The revised TPL assessment methodology has been derived through a structured Systems Engineering approach. This was a formal process which involved analyzing customer and stakeholder needs through the discipline of Systems Engineering. The results of the process confirmed the high level of completeness of the original methodology presented in [1] (as used in the Wave Energy Prize judging) and now add a significantly increased level of detail in the assessment and an improved more investment focused structure. The revised TPL also incorporates the feedback of the Wave Energy Prize judges.

  17. Draft Site Treatment Plan (DSTP), Volumes I and II

    International Nuclear Information System (INIS)

    D'Amelio, J.

    1994-01-01

    Site Treatment Plans (STP) are required for facilities at which the DOE generates or stores mixed waste. This Draft Site Treatment Plan (DSTP) the second step in a three-phase process, identifies the currently preferred options for treating mixed waste at the Savannah River Site (SRS) or for developing treatment technologies where technologies do not exist or need modification. The DSTP reflects site-specific preferred options, developed with the state's input and based on existing available information. To the extent possible, the DSTP identifies specific treatment facilities for treating the mixed waste and proposes schedules. Where the selection of specific treatment facilities is not possible, schedules for alternative activities such as waste characterization and technology assessment are provided. All schedule and cost information presented is preliminary and is subject to change. The DSTP is comprised of two volumes: this Compliance Plan Volume and the Background Volume. This Compliance Plan Volume proposes overall schedules with target dates for achieving compliance with the land disposal restrictions (LDR) of RCRA and procedures for converting the target dates into milestones to be enforced under the Order. The more detailed discussion of the options contained in the Background Volume is provided for informational purposes only

  18. Nuclear proliferation and civilian nuclear power: report of the Nonproliferation Alternative Systems Assessment Program. Volume IX. Reactor and fuel cycle descriptions

    Energy Technology Data Exchange (ETDEWEB)

    1979-12-01

    The Nonproliferation Alternative Systems Assessment Program (NASAP) has characterized and assessed various reactor/fuel-cycle systems. Volume IX provides, in summary form, the technical descriptions of the reactor/fuel-cycle systems studied. This includes the status of the system technology, as well as a discussion of the safety, environmental, and licensing needs from a technical perspective. This information was then used in developing the research, development, and demonstration (RD and D) program, including its cost and time frame, to advance the existing technology to the level needed for commercial use. Wherever possible, the cost data are given as ranges to reflect the uncertainties in the estimates. Volume IX is divided into three sections: Chapter 1, Reactor Systems; Chapter 2, Fuel-Cycle Systems; and the Appendixes. Chapter 1 contains the characterizations of the following 12 reactor types: light-water reactor; heavy-water reactor; water-cooled breeder reactor; high-temperature gas-cooled reactor; gas-cooled fast reactor; liquid-metal fast breeder reactor; spectral-shift-controlled reactor; accelerator-driven reactor; molten-salt reactor; gaseous-core reactor; tokamak fusion-fisson hybrid reactor; and fast mixed-spectrum reactor. Chapter 2 contains similar information developed for fuel-cycle facilities in the following categories: mining and milling; conversion and enrichment; fuel fabrication; spent fuel reprocessing; waste handling and disposal; and transportation of nuclear materials.

  19. Nuclear proliferation and civilian nuclear power: report of the Nonproliferation Alternative Systems Assessment Program. Volume IX. Reactor and fuel cycle descriptions

    International Nuclear Information System (INIS)

    1979-12-01

    The Nonproliferation Alternative Systems Assessment Program (NASAP) has characterized and assessed various reactor/fuel-cycle systems. Volume IX provides, in summary form, the technical descriptions of the reactor/fuel-cycle systems studied. This includes the status of the system technology, as well as a discussion of the safety, environmental, and licensing needs from a technical perspective. This information was then used in developing the research, development, and demonstration (RD and D) program, including its cost and time frame, to advance the existing technology to the level needed for commercial use. Wherever possible, the cost data are given as ranges to reflect the uncertainties in the estimates. Volume IX is divided into three sections: Chapter 1, Reactor Systems; Chapter 2, Fuel-Cycle Systems; and the Appendixes. Chapter 1 contains the characterizations of the following 12 reactor types: light-water reactor; heavy-water reactor; water-cooled breeder reactor; high-temperature gas-cooled reactor; gas-cooled fast reactor; liquid-metal fast breeder reactor; spectral-shift-controlled reactor; accelerator-driven reactor; molten-salt reactor; gaseous-core reactor; tokamak fusion-fisson hybrid reactor; and fast mixed-spectrum reactor. Chapter 2 contains similar information developed for fuel-cycle facilities in the following categories: mining and milling; conversion and enrichment; fuel fabrication; spent fuel reprocessing; waste handling and disposal; and transportation of nuclear materials

  20. Technology and public policy: The process of technology assessment in the federal government

    Science.gov (United States)

    Coates, V. T.

    1975-01-01

    A study was conducted to provide a descriptive and analytical review of the concept of technology assessment and the current status of its applications in the work of the federal executive agencies. The origin of the term technology assessment was examined along with a brief history of its discussion and development since 1966 and some of the factors influencing that development.

  1. Technology assessment of in situ uranium mining

    International Nuclear Information System (INIS)

    Cowan, C.E.

    1981-01-01

    The objective of the PNL portion of the Technology Assessment project is to provide a description of the current in situ uranium mining technology; to evaluate, based on available data, the environmental impacts and, in a limited fashion, the health effects; and to explore the impediments to development and deployment of the in situ uranium mining technology

  2. Technology assessment for Spaceship Two, space tourism, and private spaceflight

    Science.gov (United States)

    Hancock, Randy

    A seven-step technology assessment was conducted to address questions regarding the significance and likely consequences associated with the introduction of Spaceship Two, space tourism, and private spaceflight. Impacts were assessed across four categories: the Role and Functions of Government, Private Industry Factors, Cultural and Societal Impacts, and the Time Frame in which these impacts were anticipated to occur. The technology assessment findings were compared to the results of expert interviews that addressed the sane four categories. The researcher noted that, while there was overwhelming agreement between the technology assessment's primary impacts and the expert interview responses, there were several differences. The technology assessment and interviewees agreed that the federal government would likely be both a regulator and user of private spaceflight. Both agreed that business partnerships would be key in pursuing private spaceflight. There was also consensus that, as market forces come to bear, ticket prices would drop and a larger market and broader passenger demographic would emerge. The technology assessment and experts agreed that an accident, especially one early in the industry's evolution, could be disastrous. Both agreed that private spaceflight can serve as a inspiration to students and be a positive influence in society, and both agreed that the start of passenger flights should take place in the 2010 - 2012 timeframe. Due to the potentially disastrous consequences of an accident, there was agreement between the technology assessment and experts on the value of flight and ground crew training, driven by insurance carriers and federal mandate. Most differences between the technology assessment's findings and the expert interview responses were due to omission, rather than direct disagreement. However, this was not the case in every instance. The most significant difference between the technology assessment and the experts involved the

  3. Technology assessment and technology policy in Europe : New concepts, new goals, new infrastructures

    NARCIS (Netherlands)

    Smits, R.; Leyten, J.; Hertog, P. den

    1995-01-01

    Starting from the observation that the technological potentials are underutilized in economic and in social tems, this article raises the question of what role technology assessment (TA) can play in technology policy to address this problem. The causes of the problem of underutilization are analyzed

  4. Defining the "proven technology" technical criterion in the reactor technology assessment for Malaysia's nuclear power program

    Science.gov (United States)

    Anuar, Nuraslinda; Kahar, Wan Shakirah Wan Abdul; Manan, Jamal Abdul Nasir Abd

    2015-04-01

    Developing countries that are considering the deployment of nuclear power plants (NPPs) in the near future need to perform reactor technology assessment (RTA) in order to select the most suitable reactor design. The International Atomic Energy Agency (IAEA) reported in the Common User Considerations (CUC) document that "proven technology" is one of the most important technical criteria for newcomer countries in performing the RTA. The qualitative description of five desired features for "proven technology" is relatively broad and only provides a general guideline to its characterization. This paper proposes a methodology to define the "proven technology" term according to a specific country's requirements using a three-stage evaluation process. The first evaluation stage screens the available technologies in the market against a predefined minimum Technology Readiness Level (TRL) derived as a condition based on national needs and policy objectives. The result is a list of technology options, which are then assessed in the second evaluation stage against quantitative definitions of CUC desired features for proven technology. The potential technology candidates produced from this evaluation is further narrowed down to obtain a list of proven technology candidates by assessing them against selected risk criteria and the established maximum allowable total score using a scoring matrix. The outcome of this methodology is the proven technology candidates selected using an accurate definition of "proven technology" that fulfills the policy objectives, national needs and risk, and country-specific CUC desired features of the country that performs this assessment. A simplified assessment for Malaysia is carried out to demonstrate and suggest the use of the proposed methodology. In this exercise, ABWR, AP1000, APR1400 and EPR designs assumed the top-ranks of proven technology candidates according to Malaysia's definition of "proven technology".

  5. Design definition study of a life/cruise fan technology V/STOL aircraft. Volume 2, addendum 2: Program risk assessment

    Science.gov (United States)

    1975-01-01

    The results are presented of a risk assessment study conducted on two technology aircraft. The aircraft system components were reviewed and assessed for risk based on: (1) complexity relative to state-of-the-art, (2) manufacturing and qualification testing, (3) availability and delays, and (4) cost/schedule impact. These assessments were based on five risk nomenclatures: low, minor, moderate, high, and extreme. Each aircraft system was assigned an overall risk rating depending upon its contribution to the capability of the aircraft to achieve the performance goals. The slightly lower Sabreliner performance margin is due to the restricted flight envelope, the fixed landing gear, and internal fuel capacity. The Sabreliner with retractable gear and allowed to fly at its best speed and altitude would reflect performance margins similar to the New Airframe. These significant margins, inherent with the MCAIR three gas generator/three fan propulsion system, are major modifiers to risk assessment of both aircraft. The estimated risk and the associated key system and performance areas are tabulated.

  6. Assessment and monitoring of flow limitation and other parameters from flow/volume loops.

    Science.gov (United States)

    Dueck, R

    2000-01-01

    Flow/volume (F/V) spirometry is routinely used for assessing the type and severity of lung disease. Forced vital capacity (FVC) and timed vital capacity (FEV1) provide the best estimates of airflow obstruction in patients with asthma, chronic obstructive pulmonary disease (COPD) and emphysema. Computerized spirometers are now available for early home recognition of asthma exacerbation in high risk patients with severe persistent disease, and for recognition of either infection or rejection in lung transplant patients. Patients with severe COPD may exhibit expiratory flow limitation (EFL) on tidal volume (VT) expiratory F/V (VTF/V) curves, either with or without applying negative expiratory pressure (NEP). EFL results in dynamic hyperinflation and persistently raised alveolar pressure or intrinsic PEEP (PEEPi). Hyperinflation and raised PEEPi greatly enhance dyspnea with exertion through the added work of the threshold load needed to overcome raised pleural pressure. Esophageal (pleural) pressure monitoring may be added to VTF/V loops for assessing the severity of PEEPi: 1) to optimize assisted ventilation by mask or via endotracheal tube with high inspiratory flow rates to lower I:E ratio, and 2) to assess the efficacy of either pressure support ventilation (PSV) or low level extrinsic PEEP in reducing the threshold load of PEEPi. Intraoperative tidal volume F/V loops can also be used to document the efficacy of emphysema lung volume reduction surgery (LVRS) via disappearance of EFL. Finally, the mechanism of ventilatory constraint can be identified with the use of exercise tidal volume F/V loops referenced to maximum F/V loops and static lung volumes. Patients with severe COPD show inspiratory F/V loops approaching 95% of total lung capacity, and flow limitation over the entire expiratory F/V curve during light levels of exercise. Surprisingly, patients with a history of congestive heart failure may lower lung volume towards residual volume during exercise

  7. Patrick Air Force Base integrated resource assessment. Volume 2, Baseline detail

    Energy Technology Data Exchange (ETDEWEB)

    Wahlstrom, R.R.; King, D.A.; Parker, S.A.; Sandusky, W.F.

    1993-08-01

    The US Air Force has tasked the Pacific Northwest Laboratory (PNL), in support of the US Department of Energy (DOE) Federal Energy Management Program (FEMP), to assess energy use at Patrick Air Force Base (AFB). The information obtained from this assessment will be used in identifying energy resource opportunities to reduce overall energy consumption on the base. The primary focus of this report is to assess the current baseline energy consumption at Patrick AFB. It is a comparison report to Volume 1, the Executive Summary, and Volume 3, the Resource Assessment. This assessment requires that information be obtained and characterized for buildings, utilities, energy sources, energy uses, and load profile information to be used to improve the characterization of energy use on the base. The characteristics of electricity, natural gas, and No. 2 fuel oil are analyzed for on-base facilities and housing. The assessment examines basic regional information used to determine energy-use intensity (EUI) values for Patrick AFB facilities by building, fuel type, and energy end use. It also provides a summary of electricity consumption from Florida Power and Light Company (FPL) metered data for 1985-1991. Load profile information obtained from FPL data is presented for the north and south substations for the four seasons of the year, including weekdays and weekends.

  8. INFORMATION AND COMMUNICATION TECHNOLOGIES TRAINING: CRITERIA FOR INTERNAL QUALITY ASSESSMENT

    Directory of Open Access Journals (Sweden)

    Oleg M. Spirin

    2011-02-01

    Full Text Available In the article the concept of information and communication technology training is specified. It is grounded an internal criteria of information and communication technologies training quality assessment based on experience of the organization, carrying out, analysis of experimental work results on quality assessment of designing, working out, efficiency of methodical system of informatics teachers base vocational training introduction in the conditions of credit-modular technology. Indicators and approaches of their assessment to define the criteria degree are resulted. Indicators of criteria "level differentiation", "individualization" and "intensification" of educational process for information and communication technologies training quality assessment are specified.

  9. Muscle blood volume assessment during exercise with Power Doppler Ultrasound

    NARCIS (Netherlands)

    Heres, H.M.; Tchang, B.C.Y.; Schoots, T.; Rutten, M.C.M.; van de Vosse, F.N.; Lopata, R.G.P.

    2016-01-01

    Assessment of perfusion adaptation in muscle during exercise can provide diagnostic information on cardiac and endothelial diseases. Power Doppler Ultrasound (PDUS) is known for its feasibility in the non-invasive measurement of moving blood volume (MBV), a perfusion related parameter. In this

  10. FIELD DEMONSTRATION OF INNOVATIVE CONDITION ASSESSMENT TECHNOLOGIES FOR WATER MAINS: ACOUSTIC PIPE WALL ASSESSMENT, INTERNAL INSPECTION, AND EXTERNAL INSPECTIONVOLUME 1: TECHNICAL REPORT AND VOLUME 2: APPENDICES

    Science.gov (United States)

    Nine pipe wall integrity assessment technologies were demonstrated on a 76-year-old, 2,057-ft-long portion of a cement-lined, 24-in. cast iron water main in Louisville, KY. This activity was part of a series of field demonstrations of innovative leak detection/location and condi...

  11. FY 1974 report on the results of the Sunshine Project. Technology assessment of hydrogen energy technology; 1974 nendo suiso energy gijutsu no technology assessment seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1975-04-30

    This is aimed at studying the relation between the technology development of hydrogen energy and the society. In Chapter 1, a meaning of technology assessment was examined. When applying it to the hydrogen energy technology, the paper presented what content it has. In Chapter 2, the needs for hydrogen energy in society were made clear in comparison with the energy supply/demand structure in Japan and characteristics of hydrogen energy. In Chapter 3, the paper showed what kinds of technology are being developed to meet the needs in this society and arranged viewpoints for evaluating the effectiveness of the technology. In Chapter 4, the paper studied the positioning of hydrogen energy technology in the future society, and presented as examples more than one hydrogen energy/system plans which become the base to describe the impact of the technology on the society. If taking technology assessment as a part of the communication activities between the technology development and the society as did in this study, these system plans are something like the ring for people in each field to talk with. In Chapter 5, the study made from each aspect was arranged. (NEDO)

  12. New Modes of Constructive Technology Assessment for Developing Countries

    DEFF Research Database (Denmark)

    Christensen, David; Remmen, Arne

    of transformation or co-creation in a movement from one context to another, i.e. from the North to South. The question here is how to affect a proactive intake of relevant knowledge in decision-making in a technological innovation process so as to increase the likelihood of developing sustainable solutions. A co...... into actor strategies and decision-making processes. There is a variant of ‘constructive’ technology assessment that stands out as useful in multi-actor partnership settings. Placing emphasis on interactive processes, constructive technology assessment embraces active negotiation among involved parties...... in influencing technological change. In developing countries, technology assessment has received relatively little attention, but recent developments have expressed a ‘call-to-arms’ to tailor flexible approaches by ensuring the involvement of diverse stakeholders and citizens and continual learning among...

  13. Development of the destruction technology for radioactive organic solid wastes

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Won Zin; Park, H.S.; Lee, K.W. [and others

    1999-04-01

    The followings were studied through the project entitled 'Technology development for nuclear fuel cycle waste treatment'. 1. Organic waste decomposition technology development A. Destruction technology for organic wastes using Ag(2)-mediated electrochemical oxidation B. Recovery and regeneration technology for the spent chemicals used in the MEO process 2. Radioactive metal waste recycling technology A. Surface decontamination processes B. Decontamination waste treatment technology 3. Volume reduction technology nuclear fuel cycle (NFC) technology A. Estimation of the amount of radwastes and the optimum volume reduction methodology of domestic NFC B. Pretreatment of spent fuel cladding by electrochemical decontamination C. Hot cell process technology for the treatment of NFC wastes 4. Design and fabrication of the test equipment of volume reduction and reuse of alpha contaminated wastes 5. Evaluation on environmental compatibility of NFC A. Development of evaluation methodology on environmental friendliness of NFC B. Residual activity assessment of recycling wastes. (author). 321 refs., 54 tabs., 183 figs.

  14. Development of the destruction technology for radioactive organic solid wastes

    International Nuclear Information System (INIS)

    Oh, Won Zin; Park, H.S.; Lee, K.W.

    1999-04-01

    The followings were studied through the project entitled 'Technology development for nuclear fuel cycle waste treatment'. 1. Organic waste decomposition technology development A. Destruction technology for organic wastes using Ag(2)-mediated electrochemical oxidation B. Recovery and regeneration technology for the spent chemicals used in the MEO process 2. Radioactive metal waste recycling technology A. Surface decontamination processes B. Decontamination waste treatment technology 3. Volume reduction technology nuclear fuel cycle (NFC) technology A. Estimation of the amount of radwastes and the optimum volume reduction methodology of domestic NFC B. Pretreatment of spent fuel cladding by electrochemical decontamination C. Hot cell process technology for the treatment of NFC wastes 4. Design and fabrication of the test equipment of volume reduction and reuse of alpha contaminated wastes 5. Evaluation on environmental compatibility of NFC A. Development of evaluation methodology on environmental friendliness of NFC B. Residual activity assessment of recycling wastes. (author). 321 refs., 54 tabs., 183 figs

  15. Construction of knowledge base for geological disposal technologies of high-level radioactive waste Report in 2005. Separate volume 3: Development of safety assessment methods

    International Nuclear Information System (INIS)

    2005-09-01

    The results of development of safety assessment methods by JNC after the second report are reported. JNC-Thermodynamic and JNC-Sorption Database of nuclides was prepared and used. The mass transfer process model in rock, the water quality model of underwater and pore water and approach to modeling radionuclide transport in biosphere were improved. The phenomenological nuclide transport model and the effect assessment model of colloid, natural organic compounds and microorganism were developed. On scenario of safety assessment method, the behaviors in the disposal system were expressed by FEP (Features, Events, and Processes). The effects of data uncertainty and model uncertainty were improved by the assessment technologies and the sensitivity analysis technology. JGIS (JNC Geological Disposal Information Integration System) was developed. The main performance of JGIS was shown. It consists of six chapters; the first chapter is introduction, the second chapter the nuclides transport database, the third the safety assessment model, the forth improvement of safety assessment methods, the fifth application of safety assessment methods and the sixth results and summary. (S.Y.)

  16. Life Cycle Assessment of Slurry Management Technologies

    DEFF Research Database (Denmark)

    Wesnæs, Marianne; Wenzel, Henrik; Petersen, Bjørn Molt

    This report contains the results of Life Cycle Assessments of two slurry management technologies - acidification and decentred incineration. The LCA foundation can be used by the contributing companies for evaluating the environmental sustainability of a specific technology from a holistic Life...... Cycle perspective. Through this the companies can evaluate the environmental benefits and disadvantages of introducing a specific technology for slurry management. From a societal perspective the results can contribute to a clarification of which slurry management technologies (or combination...... of technologies) having the largest potential for reducing the overall environmental impacts....

  17. DECISION ANALYSIS AND TECHNOLOGY ASSESSMENTS FOR METAL AND MASONRY DECONTAMINATION TECHNOLOGIES

    International Nuclear Information System (INIS)

    Ebadian, M.A.

    1999-01-01

    The purpose of this investigation was to conduct a comparative analysis of innovative technologies for the non-aggressive removal of coatings from metal and masonry surfaces and the aggressive removal of one-quarter to one-inch thickness of surface from structural masonry. The technologies tested should be capable of being used in nuclear facilities. Innovative decontamination technologies are being evaluated under standard, non-nuclear conditions at the FIU-HCET technology assessment site in Miami, Florida. This study is being performed to support the OST, the Deactivation and Decommissioning (D and D) Focus Area, and the environmental restoration of DOE facilities throughout the DOE complex by providing objective evaluations of currently available decontamination technologies

  18. Health technology assessment in Iran: challenges and views

    Science.gov (United States)

    Olyaeemanesh, Alireza; Doaee, Shila; Mobinizadeh, Mohammadreza; Nedjati, Mina; Aboee, Parisa; Emami-Razavi, Seyed Hassan

    2014-01-01

    Background: Various decisions have been made on technology application at all levels of the health system in different countries around the world. Health technology assessment is considered as one of the best scientific tools at the service of policy- makers. This study attempts to investigate the current challenges of Iran’s health technology assessment and provide appropriate strategies to establish and institutionalize this program. Methods: This study was carried out in two independent phases. In the first, electronic databases such as Medline (via Pub Med) and Scientific Information Database (SID) were searched to provide a list of challenges of Iran’s health technology assessment. The views and opinions of the experts and practitioners on HTA challenges were studied through a questionnaire in the second phase which was then analyzed by SPSS Software version 16. This has been an observational and analytical study with a thematic analysis. Results: In the first phase, seven papers were retrieved; from which, twenty- two HTA challenges in Iran were extracted by the researchers; and they were used as the base for designing a structured questionnaire of the second phase. The views of the experts on the challenges of health technology assessment were categorized as follows: organizational culture, stewardship, stakeholders, health system management, infrastructures and external pressures which were mentioned in more than 60% of the cases and were also common in the views. Conclusion: The identification and prioritization of HTA challenges which were approved by those experts involved in the strategic planning of the Department of Health Technology Assessment will be a step forward in the promotion of an evidence- based policy- making and in the production of comprehensive scientific evidence. PMID:25695015

  19. Technology and Current Reading/Literacy Assessment Strategies

    Science.gov (United States)

    Balajthy, Ernest

    2007-01-01

    Computer-based technologies offer promise as a means to assess students and provide teachers with better understandings of their students' achievement. This article describes recent developments in computer-based and web-based reading and literacy assessment, focusing on assessment administration, information management, and report creation. In…

  20. Proceedings of the twenty-fourth water reactor safety information meeting. Volume 3: PRA and HRA; Probabilistic seismic hazard assessment and seismic siting criteria

    Energy Technology Data Exchange (ETDEWEB)

    Monteleone, S. [comp.] [Brookhaven National Lab., Upton, NY (United States)

    1997-02-01

    This three-volume report contains papers presented at the Twenty-Fourth Water Reactor Safety Information Meeting held at the Bethesda Marriott Hotel, Bethesda, Maryland, October 21--23, 1996. The papers are printed in the order of their presentation in each session and describe progress and results of programs in nuclear safety research conducted in this country and abroad. Foreign participation in the meeting included papers presented by researchers from Czech Republic, Finland, France, Japan, Norway, Russia and United Kingdom. This volume is divided into the following sections: PRA and HRA and probabilistic seismic hazard assessment and seismic siting criteria. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database.

  1. Proceedings of the twenty-fourth water reactor safety information meeting. Volume 3: PRA and HRA; Probabilistic seismic hazard assessment and seismic siting criteria

    International Nuclear Information System (INIS)

    Monteleone, S.

    1997-02-01

    This three-volume report contains papers presented at the Twenty-Fourth Water Reactor Safety Information Meeting held at the Bethesda Marriott Hotel, Bethesda, Maryland, October 21--23, 1996. The papers are printed in the order of their presentation in each session and describe progress and results of programs in nuclear safety research conducted in this country and abroad. Foreign participation in the meeting included papers presented by researchers from Czech Republic, Finland, France, Japan, Norway, Russia and United Kingdom. This volume is divided into the following sections: PRA and HRA and probabilistic seismic hazard assessment and seismic siting criteria. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database

  2. Principles of sustainability science to assess alternative energy technologies

    CSIR Research Space (South Africa)

    Brent, AC

    2009-04-01

    Full Text Available , adaptive capacity, and complexity of social-ecological systems to assess the potential of such technologies for increasing the carrying capacity and improving the resilience of social-ecological systems, or to assess the resilience of the technological...

  3. Editorial Commentary: Single-Image Slice Magnetic Resonance Imaging Assessments Do Not Predict 3-Dimensional Muscle Volume.

    Science.gov (United States)

    Brand, Jefferson C

    2016-01-01

    No single-image magnetic resonance imaging (MRI) assessment-Goutallier classification, Fuchs classification, or cross-sectional area-is predictive of whole-muscle volume or fatty atrophy of the supraspinatus or infraspinatus. Rather, 3-dimensional MRI measurement of whole-muscle volume and fat-free muscle volume is required and is associated with shoulder strength, which is clinically relevant. Three-dimensional MRI may represent a new gold standard for assessment of the rotator cuff musculature using imaging and may help to predict the feasibility of repair of a rotator cuff tear as well as the postoperative outcome. Unfortunately, 3-dimensional MRI assessment of muscle volume is labor intensive and is not widely available for clinical use. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  4. Technology-Supported Performance Assessments for Middle School Geoscience

    Science.gov (United States)

    Zalles, D. R.; Quellmalz, E.; Rosenquist, A.; Kreikemeier, P.

    2002-12-01

    Under funding from the World Bank, the U.S. Department of Education, the National Science Foundation, and the Federal Government's Global Learning and Observations to Benefit the Environment Program (GLOBE), SRI International has developed and piloted web-accessible performance assessments that measure K-12 students' abilities to use learning technologies to reason with scientific information and communicate evidence-based conclusions to scientific problems. This presentation will describe the assessments that pertain to geoscience at the middle school level. They are the GLOBE Assessments and EPA Phoenix, an instantiation of SRI's model of assessment design known as Integrative Performance Assessments in Technology (IPAT). All are publicly-available on the web. GLOBE engages students in scientific data collection and observation about the environment. SRI's classroom assessments for GLOBE provide sample student assessment tools and frameworks that allow teachers and students to assess how well students can use the data in scientific inquiry projects. Teachers can use classroom assessment tools on the site to develop integrated investigations for assessing GLOBE within their particular science curricula. Rubrics are provided for measuring students' GLOBE-related skills, and alignments are made to state, national, and international science standards. Sample investigations are provided about atmosphere, hydrology, landcover, soils, earth systems, and visualizations. The IPAT assessments present students with engaging problems rooted in science or social science content, plus sets of tasks and questions that require them to gather relevant information on the web, use reasoning strategies to analyze and interpret the information, use spreadsheets, word processors, and other productivity tools, and communicate evidence-based findings and recommendations. In the process of gathering information and drawing conclusions, students are assessed on how well they can operate

  5. Beyond checklists: toward an ethical-constructive technology assessment

    NARCIS (Netherlands)

    Kiran, Asle; Oudshoorn, Nelly E.J.; Verbeek, Peter P.C.C.

    2015-01-01

    While many technology assessments (TAs) formally conducted by TA organizations in Europe and the USA have examined the implications of new technologies for ‘quantifiable risks’ regarding safety, health or the environment, they have largely ignored the ethical implications of those technologies.

  6. Integration of tablet technologies in the e-laboratory of cytology: a health technology assessment.

    Science.gov (United States)

    Giansanti, Daniele; Pochini, Marco; Giovagnoli, Maria Rosaria

    2014-10-01

    Although tablet systems are becoming a powerful technology, particularly useful in every application of medical imaging, to date no one has investigated the acceptance and performance of this technology in digital cytology. The specific aims of the work were (1) to design a health technology assessment (HTA) tool to assess, in terms of performance and acceptance, the introduction of tablet technologies (wearable, portable, and non portable) in the e-laboratories of cytology and (2) to test the tool in a first significant application of digital cytology. An HTA tool was proposed operating on a domain of five dimensions of investigation comprising the basic information of the product of digital cytology, the perceived subjective quality of images, the assessment of the virtual navigation on the e-slide, the assessment of the information and communication technologies features, and the diagnostic power. Six e-slides regarding studies of cervicovaginal cytology digitalized by means of an Aperio ( www.aperio.com ) scanner and uploaded onto the www.digitalslide.it Web site were used for testing the methodology on three different network connections. Three experts of cytology successfully tested the methodology on seven tablets found suitable for the study in their own standard configuration. Specific indexes furnished by the tool indicated both a high degree of performance and subjective acceptance of the investigated technology. The HTA tool thus could be useful to investigate new tablet technologies in digital cytology and furnish stakeholders with useful information that may help them make decisions involving the healthcare system. From a global point of view the study demonstrates the feasibility of using the tablet technology in digital cytology.

  7. Biomass Gasification Technology Assessment: Consolidated Report

    Energy Technology Data Exchange (ETDEWEB)

    Worley, M.; Yale, J.

    2012-11-01

    Harris Group Inc. (HGI) was commissioned by the National Renewable Energy Laboratory to assess gasification and tar reforming technologies. Specifically, the assessments focused on gasification and tar reforming technologies that are capable of producing a syngas suitable for further treatment and conversion to liquid fuels. HGI gathered sufficient information to analyze three gasification and tar reforming systems. This report summarizes the equipment, general arrangement of the equipment, operating characteristics, and operating severity for each technology. The order of magnitude capital cost estimates are supported by a basis-of-estimate write-up, which is also included in this report. The report also includes Microsoft Excel workbook models, which can be used to design and price the systems. The models can be used to analyze various operating capacities and pressures. Each model produces a material balance, equipment list, capital cost estimate, equipment drawings and preliminary general arrangement drawings. Example outputs of each model are included in the Appendices.

  8. Second interim assessment of the Canadian concept for nuclear fuel waste disposal. Volume 4

    International Nuclear Information System (INIS)

    Wuschke, D.M.; Gillespie, P.A.; Mehta, K.K.; Henrich, W.F.; LeNeveu, D.M.; Guvanasen, V.M.; Sherman, G.R.; Donahue, D.C.; Goodwin, B.W.; Andres, T.H.

    1985-12-01

    The nuclear fuel waste disposal concept chosen for development and assessment in Canada involves the isolation of corrosion-resistant containers of waste in a vault located deep in plutonic rock. As the concept and the assessment tools are developed, periodic assessments are performed to permit evaluation of the methodology and provide feedback to those developing the concept. The ultimate goal of these assessments is to predict what impact the disposal system would have on man and the environment if the concept were implemented. The second such assessment was performed in 1984 and is documented in the Second Interim Assessment of the Canadian Concept for Nuclear Fuel Waste Disposal - Volumes 1-4. This volume, entitled Post-Closure Assessment, describes the methods, models and data used to perform the second post-closure assessment. The results are presented and their significance is discussed. Conclusions and planned improvements are listed. 72 refs

  9. Assessment of accident risks in the CRBRP. Volume 2. Appendices

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-03-01

    Appendices to Volume I include core-related accident-sequence definition, CRBRP risk-assessment sequence-probability determinations, failure-probability data, accident scenario evaluation, radioactive material release analysis, ex-core accident analysis, safety philosophy and design features, calculation of reactor accident consequences, sensitivity study, and risk from fires.

  10. Methodology of constructive technology assessment in health care

    NARCIS (Netherlands)

    Douma, Kirsten F. L.; Karsenberg, Kim; Hummel, Marjan J. M.; Bueno-de-Mesquita, Jolien M.; van Harten, Wim H.

    2007-01-01

    OBJECTIVES: Technologies in health care are evolving quickly, with new findings in the area of biotechnological and genetic research being published regularly. A health technology assessment (HTA) is often used to answer the question of whether the new technology should be implemented into clinical

  11. Methodology of constructive technology assessment in health care

    NARCIS (Netherlands)

    Douma, Kirsten F.L.; Hummel, J. Marjan; Karsenberg, Kim; van Harten, Willem H.; Bueno-de-Mesquita, Jolien M.

    2007-01-01

    Objectives: Technologies in health care are evolving quickly, with new findings in the area of biotechnological and genetic research being published regularly. A health technology assessment (HTA) is often used to answer the question of whether the new technology should be implemented into clinical

  12. Assessment Training Effects on Student Assessment Skills and Task Performance in a Technology-Facilitated Peer Assessment

    Science.gov (United States)

    Liu, Xiongyi; Li, Lan

    2014-01-01

    This study examines the impact of an assessment training module on student assessment skills and task performance in a technology-facilitated peer assessment. Seventy-eight undergraduate students participated in the study. The participants completed an assessment training exercise, prior to engaging in peer-assessment activities. During the…

  13. A Suite of Tools for Technology Assessment

    Science.gov (United States)

    2007-09-01

    Saden, Povinelli & Rosen, 1989). • This was a significant change in emphasis on the part of NASA, where technology had previously viewed as merely...Cost Analysis Symposium, April 13, 2005. A Suite of Tools for Technology Assessment 24 Bibliography - continued: • Sadin, Stanley T.; Povinelli

  14. Information technology resources assessment

    Energy Technology Data Exchange (ETDEWEB)

    Loken, S.C. [ed.

    1993-01-01

    The emphasis in Information Technology (IT) development has shifted from technology management to information management, and the tools of information management are increasingly at the disposal of end-users, people who deal with information. Moreover, the interactive capabilities of technologies such as hypertext, scientific visualization, virtual reality, video conferencing, and even database management systems have placed in the hands of users a significant amount of discretion over how these resources will be used. The emergence of high-performance networks, as well as network operating systems, improved interoperability, and platform independence of applications will eliminate technical barriers to the use of data, increase the power and range of resources that can be used cooperatively, and open up a wealth of possibilities for new applications. The very scope of these prospects for the immediate future is a problem for the IT planner or administrator. Technology procurement and implementation, integration of new technologies into the existing infrastructure, cost recovery and usage of networks and networked resources, training issues, and security concerns such as data protection and access to experiments are just some of the issues that need to be considered in the emerging IT environment. As managers we must use technology to improve competitiveness. When procuring new systems, we must take advantage of scalable resources. New resources such as distributed file systems can improve access to and efficiency of existing operating systems. In addition, we must assess opportunities to improve information worker productivity and information management through tedmologies such as distributed computational visualization and teleseminar applications.

  15. Assessment of sphenoid sinus volume in order to determine sexual identity, using multi-slice CT images

    Directory of Open Access Journals (Sweden)

    Habibeh Farazdaghi

    2017-02-01

    Full Text Available Background and Aims: Gender determination is an important step in identification. For gender determination, anthropometric evaluation is one of the main forensic evaluations. The aim of this study was the assessment of sphenoid sinus volume in order to determine sexual identity, using multi-slice CT images. Materials and Methods: For volumetric analysis, axial paranasal sinus CT scan with 3-mm slice thickness was used. For this study, 80 images (40 women and 40 men older than 18 years were selected. For the assessment of sphenoid sinus volume, Digimizer software was used. The volume of sphenoid sinus was calculated using the following equation: v=∑ (area of each slice × thickness of each slice. Statistical analysis was performed by independent T-test. Results: The mean volume of sphenoid sinus was significantly greater in male gender (P=0.01.The assessed Cut off point was 9/35 cm3, showing that 63.4% of volume assessments greater than cut off point was supposed to be male and 64.1% of volumetry lesser than cut off point were female. Conclusion: According to the area under Roc curve (1.65%, sphenoid sinus volume is not an appropriate factor for differentiation of male and female from each other, which means the predictability of cut off point (9/35 cm3 is 65/1% close to reality.

  16. Health Information Technology Usability Evaluation Scale (Health-ITUES) for Usability Assessment of Mobile Health Technology: Validation Study.

    Science.gov (United States)

    Schnall, Rebecca; Cho, Hwayoung; Liu, Jianfang

    2018-01-05

    Mobile technology has become a ubiquitous technology and can be particularly useful in the delivery of health interventions. This technology can allow us to deliver interventions to scale, cover broad geographic areas, and deliver technologies in highly tailored ways based on the preferences or characteristics of users. The broad use of mobile technologies supports the need for usability assessments of these tools. Although there have been a number of usability assessment instruments developed, none have been validated for use with mobile technologies. The goal of this work was to validate the Health Information Technology Usability Evaluation Scale (Health-ITUES), a customizable usability assessment instrument in a sample of community-dwelling adults who were testing the use of a new mobile health (mHealth) technology. A sample of 92 community-dwelling adults living with HIV used a new mobile app for symptom self-management and completed the Health-ITUES to assess the usability of the app. They also completed the Post-Study System Usability Questionnaire (PSSUQ), a widely used and well-validated usability assessment tool. Correlations between these scales and each of the subscales were assessed. The subscales of the Health-ITUES showed high internal consistency reliability (Cronbach alpha=.85-.92). Each of the Health-ITUES subscales and the overall scale was moderately to strongly correlated with the PSSUQ scales (r=.46-.70), demonstrating the criterion validity of the Health-ITUES. The Health-ITUES has demonstrated reliability and validity for use in assessing the usability of mHealth technologies in community-dwelling adults living with a chronic illness. ©Rebecca Schnall, Hwayoung Cho, Jianfang Liu. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 05.01.2018.

  17. Geostatistical approach for assessing soil volumes requiring remediation: validation using lead-polluted soils underlying a former smelting works.

    Science.gov (United States)

    Demougeot-Renard, Helene; De Fouquet, Chantal

    2004-10-01

    Assessing the volume of soil requiring remediation and the accuracy of this assessment constitutes an essential step in polluted site management. If this remediation volume is not properly assessed, misclassification may lead both to environmental risks (polluted soils may not be remediated) and financial risks (unexpected discovery of polluted soils may generate additional remediation costs). To minimize such risks, this paper proposes a geostatistical methodology based on stochastic simulations that allows the remediation volume and the uncertainty to be assessed using investigation data. The methodology thoroughly reproduces the conditions in which the soils are classified and extracted at the remediation stage. The validity of the approach is tested by applying it on the data collected during the investigation phase of a former lead smelting works and by comparing the results with the volume that has actually been remediated. This real remediated volume was composed of all the remediation units that were classified as polluted after systematic sampling and analysis during clean-up stage. The volume estimated from the 75 samples collected during site investigation slightly overestimates (5.3% relative error) the remediated volume deduced from 212 remediation units. Furthermore, the real volume falls within the range of uncertainty predicted using the proposed methodology.

  18. Risk assessments of innovative technologies for treatment of mixed waste

    International Nuclear Information System (INIS)

    Ragaini, R.C.; Aycock, M.T.; Russell, J.E.

    1993-01-01

    The mission of the US Department of Energy's (DOE'S) Mixed Waste Integrated Program (MWIP) is to develop complete and appropriate technologies for the treatment of DOE mixed low-level waste and transuranic wastes in order to ensure that all affected DOE installations and projects can come into compliance with environmental law and meet DOE's 30-yr cleanup and operational goals. The MWIP will achieve its goal by developing technologies that are in compliance with regulatory requirements, are socially and politically viable, and are cost beneficial and effective in disposed waste source term and volume reduction. The project management plan for MWIP requires that technologies be evaluated in accordance with criteria that rank technologies with regard to performance, risk, and cost-effectiveness. This paper addresses the methodology used to rank alternative mixed-water treatment technologies with regard to relative risk

  19. Current mHealth technologies for physical activity assessment and promotion.

    Science.gov (United States)

    O'Reilly, Gillian A; Spruijt-Metz, Donna

    2013-10-01

    Novel mobile assessment and intervention capabilities are changing the face of physical activity (PA) research. A comprehensive systematic review of how mobile technology has been used for measuring PA and promoting PA behavior change is needed. Article collection was conducted using six databases from February to June 2012 with search terms related to mobile technology and PA. Articles that described the use of mobile technologies for PA assessment, sedentary behavior assessment, and/or interventions for PA behavior change were included. Articles were screened for inclusion and study information was extracted. Analyses were conducted from June to September 2012. Mobile phone-based journals and questionnaires, short message service (SMS) prompts, and on-body PA sensing systems were the mobile technologies most utilized. Results indicate that mobile journals and questionnaires are effective PA self-report measurement tools. Intervention studies that reported successful promotion of PA behavior change employed SMS communication, mobile journaling, or both SMS and mobile journaling. mHealth technologies are increasingly being employed to assess and intervene on PA in clinical, epidemiologic, and intervention research. The wide variations in technologies used and outcomes measured limit comparability across studies, and hamper identification of the most promising technologies. Further, the pace of technologic advancement currently outstrips that of scientific inquiry. New adaptive, sequential research designs that take advantage of ongoing technology development are needed. At the same time, scientific norms must shift to accept "smart," adaptive, iterative, evidence-based assessment and intervention technologies that will, by nature, improve during implementation. © 2013 American Journal of Preventive Medicine.

  20. Second interim assessment of the Canadian concept for nuclear fuel waste disposal. Volume 3

    International Nuclear Information System (INIS)

    Johansen, K.; Donnelly, K.J.; Gee, J.H.; Green, B.J.; Nathwani, J.S.; Quinn, A.M.; Rogers, B.G.; Stevenson, M.A.; Dunford, W.E.; Tamm, J.A.

    1985-12-01

    The nuclear fuel waste disposal concept chosen for development and assessment in Canada involves the isolation of corrosion-resistant containers of waste in a vault located deep in plutonic rock. As the concept and the assessment tools are developed, periodic assessments are performed to permit evaluation of the methodology and provide feedback to those developing the concept. The ultimate goal of these assessments is to predict what impact the disposal system would have on man and the environment if the concept were implemented. The second such assessment was completed in 1984 and is documented in the Second Interim Assessment of the Canadian Concept for Nuclear Fuel Waste Disposal - Volumes 1-4. This, the third volume of the report, summarizes the pre-closure environmental and safety assessments completed by Ontario Hydro for Atomic Energy of Canada Limited. The preliminary results and their sigificance are discussed. 85 refs

  1. Assessment of the health and environmental effects of power generation in the Midwest. Volume II. Ecological effects

    Energy Technology Data Exchange (ETDEWEB)

    Dvorak, A J; Pentecost, E D

    1977-04-01

    This report presents an initial evaluation of the major health and environmental issues associated with increased coal use in the six Midwestern states of Illinois, Indiana, Michigan, Minnesota, Ohio, and Wisconsin. Using an integrated assessment approach, the evaluation proceeds from a base-line scenario of energy demand and facility siting for the period 1975 to 2020. Emphasis is placed on impacts from coal extraction, land reclamation, coal combustion for electrical generation, and coal gasification. The range of potential impacts and constraints is illustrated by a second scenario that represents an expected upper limit for coal utilization in Illinois. Volume I of the report includes a characterization of the energy demand and siting scenarios, coal related technologies, and coal resources, and the related impacts on air quality, water quality, and human health. Volume II includes background information on the native ecosystems, climate, soils, and agricultural land use and a description of the ecological impacts expected from coal utilization in southern Illinois, which as ecosystems representative of a large segment of the six-state area.

  2. Fort Stewart integrated resource assessment. Volume 3: Resource assessment

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, G.P.; Keller, J.M.; Stucky, D.J.; Wahlstrom, R.R.; Larson, L.L.

    1993-10-01

    The US Army Forces Command (FORSCOM) has tasked the US Department of Energy (DOE) Federal Energy Management Program (FEMP), supported by the Pacific Northwest Laboratory, to identify, evaluate, and assist in acquiring all cost-effective energy projects at Fort Stewart. This is part of a model program that PNL is designing to support energy-use decisions in the federal sector. This report provides the results of the fossil fuel and electric energy resource opportunity (ERO) assessments performed by PNL at the FORSCOM Fort Stewart facility located approximately 25 miles southwest of Savannah, Georgia. It is a companion report to Volume 1, Executive Summary, and Volume 2, Baseline Detail. The results of the analyses of EROs are presented in 11 common energy end-use categories (e.g., boilers and furnaces, service hot water, and building lighting). A narrative description of each ERO is provided, along with a table detailing information on the installed cost, energy and dollar savings; impacts on operations and maintenance (O&M); and, when applicable, a discussion of energy supply and demand, energy security, and environmental issues. A description of the evaluation methodologies and technical and cost assumptions is also provided for each ERO. Summary tables present the cost-effectiveness of energy end-use equipment before and after the implementation of each ERO. The tables also present the results of the life-cycle cost (LCC) analysis indicating the net present value (NPV) and savings to investment ratio (SIR) of each ERO.

  3. Augmented Reality Tower Technology Assessment

    Science.gov (United States)

    Reisman, Ronald J.; Brown, David M.

    2009-01-01

    Augmented Reality technology may help improve Air Traffic Control Tower efficiency and safety during low-visibility conditions. This paper presents the assessments of five off-duty controllers who shadow-controlled' with an augmented reality prototype in their own facility. Initial studies indicated unanimous agreement that this technology is potentially beneficial, though the prototype used in the study was not adequate for operational use. Some controllers agreed that augmented reality technology improved situational awareness, had potential to benefit clearance, control, and coordination tasks and duties and could be very useful for acquiring aircraft and weather information, particularly aircraft location, heading, and identification. The strongest objections to the prototype used in this study were directed at aircraft registration errors, unacceptable optical transparency, insufficient display performance in sunlight, inadequate representation of the static environment and insufficient symbology.

  4. Proceedings of the national symposium on vacuum science and technology and power beams. Volume 2

    International Nuclear Information System (INIS)

    Venkatramani, N.; Ray, A.K.

    1997-11-01

    This volume contains the proceedings of the national symposium on vacuum science and technology and power beams. The main topics dealt with are: accelerators and vacuum systems, thin films deposition techniques, lasers and electron power beams and their applications in nuclear facilities. Papers relevant to INIS are indexed separately

  5. IMPORTANCE OF CONTEXTUAL DATA IN PRODUCING HEALTH TECHNOLOGY ASSESSMENT RECOMMENDATIONS: A CASE STUDY.

    Science.gov (United States)

    Poder, Thomas G; Bellemare, Christian A

    2018-01-01

    Contextual data and local expertise are important sources of data that cannot be ignored in hospital-based health technology assessment (HTA) processes. Despite a lack of or unconvincing evidence in the scientific literature, technology can be recommended in a given context. We illustrate this using a case study regarding biplane angiography for vascular neurointervention. A systematic literature review was conducted, along with an analysis of the context in our setting. The outcomes of interest were radiation doses, clinical complications, procedure times, purchase cost, impact on teaching program, the confidence of clinicians in the technology, quality of care, accessibility, and the volume of activity. A committee comprising managers, clinical experts, physicians, physicists and HTA experts was created to produce a recommendation regarding biplane technology acquisition to replace a monoplane device. The systematic literature review yielded nine eligible articles for analysis. Despite a very low level of evidence in the literature, the biplane system appears to reduce ionizing radiation and medical complications, as well as shorten procedure time. Contextual data indicated that the biplane system could improve operator confidence, which could translate into reduced risk, particularly for complex procedures. In addition, the biplane system can support our institution in its advanced procedures teaching program. Given the advantages provided by the biplane technology in our setting, the committee has recommended its acquisition. Contextual data were of utmost importance in this recommendation. Moreover, this technology should be implemented alongside a responsibility to collect outcome data to optimize clinical protocol in the doses of ionizing delivered.

  6. Natural-technological risk assessment and management

    Science.gov (United States)

    Burova, Valentina; Frolova, Nina

    2016-04-01

    EM-DAT statistical data on human impact and economic damages in the 1st semester 2015 are the highest since 2011: 41% of disasters were floods, responsible for 39% of economic damage and 7% of events were earthquakes responsible for 59% of total death toll. This suggests that disaster risk assessment and management still need to be improved and stay the principle issue in national and international related programs. The paper investigates the risk assessment and management practice in the Russian Federation at different levels. The method is proposed to identify the territories characterized by integrated natural-technological hazard. The maps of the Russian Federation zoning according to the integrated natural-technological hazard level are presented, as well as the procedure of updating the integrated hazard level taking into account the activity of separate processes. Special attention is paid to data bases on past natural and technological processes consequences, which are used for verification of current hazard estimation. The examples of natural-technological risk zoning for the country and some regions territory are presented. Different output risk indexes: both social and economic, are estimated taking into account requirements of end-users. In order to increase the safety of population of the Russian Federation the trans-boundaries hazards are also taken into account.

  7. Knowledge in health technology assessment

    DEFF Research Database (Denmark)

    Tjørnhøj-Thomsen, Tine; Hansen, Helle Ploug

    2011-01-01

    Health systems are placing more and more emphasis on designing and delivering services that are focused on the patient, and there is a growing interest in patient aspects of health policy research and health technology assessment (HTA). Only a few HTA agencies use and invest in scientific methods...... to generate knowledge and evidence about the patient aspects of a given technology. This raises questions about how knowledge is produced in HTA reports and what kind of knowledge is considered relevant. This article uses a Danish HTA on patient education from 2009 as empirical material for a critical...

  8. New municipal solid waste processing technology reduces volume and provides beneficial reuse applications for soil improvement and dust control

    Science.gov (United States)

    A garbage-processing technology has been developed that shreds, sterilizes, and separates inorganic and organic components of municipal solid waste. The technology not only greatly reduces waste volume, but the non-composted byproduct of this process, Fluff®, has the potential to be utilized as a s...

  9. An environmental assessment system for environmental technologies

    DEFF Research Database (Denmark)

    Clavreul, Julie; Baumeister, Hubert; Christensen, Thomas Højlund

    2014-01-01

    A new model for the environmental assessment of environmental technologies, EASETECH, has been developed. The primary aim of EASETECH is to perform life-cycle assessment (LCA) of complex systems handling heterogeneous material flows. The objectives of this paper are to describe the EASETECH...

  10. Cell dispensing in low-volume range with the immediate drop-on-demand technology (I-DOT).

    Science.gov (United States)

    Schober, Lena; Büttner, Evy; Laske, Christopher; Traube, Andrea; Brode, Tobias; Traube, Andreas Florian; Bauernhansl, Thomas

    2015-04-01

    Handling and dosing of cells comprise the most critical step in the microfabrication of cell-based assay systems for screening and toxicity testing. Therefore, the immediate drop-on-demand technology (I-DOT) was developed to provide a flexible noncontact liquid handling system enabling dispensing of cells and liquid without the risk of cross-contamination down to a precise volume in the nanoliter range. Liquid is dispensed from a source plate within nozzles at the bottom by a short compressed air pulse that is given through a quick release valve into the well, thus exceeding the capillary pressure in the nozzle. Droplets of a defined volume can be spotted directly onto microplates or other cell culture devices. We present a study on the performance and biological impact of this technology by applying the cell line MCF-7, human fibroblasts, and human mesenchymal stem cells (hMSCs). For all cell types tested, viability after dispensing is comparable to the control and exhibits similar proliferation rates in the absence of apoptotic cells, and the differentiation potential of hMSCs is not impaired. The immediate drop-on-demand technology enables accurate cell dosage and offers promising potential for single-cell applications. © 2014 Society for Laboratory Automation and Screening.

  11. The Office for Technology Assessment with the German Parliament (TAB)

    International Nuclear Information System (INIS)

    Grunwald, A.; Petermann, T.

    2004-01-01

    TAB was created in 1990 with the aim of providing contributions to the improvement of the information base, particularly for parliamentary decision-making concerning science and technology. Among TAB's tasks are above all the conception and execution of technology assessment projects and the monitoring and analysis of important scientific and technological trends and related societal developments. TAB is managed by the Institute for Technology Assessment and Systems Analysis (ITAS) of the Karlsruhe Research Center. (orig.)

  12. Evaluation of spacecraft technology programs (effects on communication satellite business ventures), volume 1

    Science.gov (United States)

    Greenburg, J. S.; Gaelick, C.; Kaplan, M.; Fishman, J.; Hopkins, C.

    1985-01-01

    Commercial organizations as well as government agencies invest in spacecraft (S/C) technology programs that are aimed at increasing the performance of communications satellites. The value of these programs must be measured in terms of their impacts on the financial performane of the business ventures that may ultimately utilize the communications satellites. An economic evaluation and planning capability was developed and used to assess the impact of NASA on-orbit propulsion and space power programs on typical fixed satellite service (FSS) and direct broadcast service (DBS) communications satellite business ventures. Typical FSS and DBS spin and three-axis stabilized spacecraft were configured in the absence of NASA technology programs. These spacecraft were reconfigured taking into account the anticipated results of NASA specified on-orbit propulsion and space power programs. In general, the NASA technology programs resulted in spacecraft with increased capability. The developed methodology for assessing the value of spacecraft technology programs in terms of their impact on the financial performance of communication satellite business ventures is described. Results of the assessment of NASA specified on-orbit propulsion and space power technology programs are presented for typical FSS and DBS business ventures.

  13. Second interim assessment of the Canadian concept for nuclear fuel waste disposal. Volume 2

    International Nuclear Information System (INIS)

    Gillespie, P.A.; Wuschke, D.M.; Guvanasen, V.M.; Mehta, K.K.; McConnell, D.B.; Tamm, J.A.; Lyon, R.B.

    1985-12-01

    The nuclear fuel waste disposal concept chosen for development and assessment in Canada involves the burial of corrosion-resistant containers of waste in a vault located deep in plutonic rock in the Canadian Shield. As the concept and the assessment tools are developed, periodic assessments are performed to permit evaluatin of the methodology and provide feedback to those developing the concept. The ultimate goal of these assessments is to predict what impact the disposal system would have if the concept were implemented. The second assessment was performed in 1984 and is documented in Second Interim Assessment of the Canadian Concept for Nuclear Fuel Waste Disposal - Volumes 1 to 4. This volume, entitled Background, discusses Canadian nuclear fuel wastes and the desirable features of a waste disposal method. It outlines several disposal options being considered by a number of countries, including the option chosen for development and assessment in Canada. The reference disposal systems assumed for the second assessment are described, and the approach used for concept assessment is discussed briefly. 79 refs

  14. Development of safety related technology and infrastructure for safety assessment

    International Nuclear Information System (INIS)

    Venkat Raj, V.

    1997-01-01

    Development and optimum utilisation of any technology calls for the building up of the necessary infrastructure and backup facilities. This is particularly true for a developing country like India and more so for an advanced technology like nuclear technology. Right from the inception of its nuclear power programme, the Indian approach has been to develop adequate infrastructure in various areas such as design, construction, manufacture, installation, commissioning and safety assessment of nuclear plants. This paper deals with the development of safety related technology and the relevant infrastructure for safety assessment. A number of computer codes for safety assessment have been developed or adapted in the areas of thermal hydraulics, structural dynamics etc. These codes have undergone extensive validation through data generated in the experimental facilities set up in India as well as participation in international standard problem exercises. Side by side with the development of the tools for safety assessment, the development of safety related technology was also given equal importance. Many of the technologies required for the inspection, ageing assessment and estimation of the residual life of various components and equipment, particularly those having a bearing on safety, were developed. This paper highlights, briefly, the work carried out in some of the areas mentioned above. (author)

  15. ENVIRONMENTAL IMPACT ASSESSMENT OF A HEALTH TECHNOLOGY: A SCOPING REVIEW.

    Science.gov (United States)

    Polisena, Julie; De Angelis, Gino; Kaunelis, David; Gutierrez-Ibarluzea, Iñaki

    2018-06-13

    The Health Technology Expert Review Panel is an advisory body to Canadian Agency for Drugs and Technologies in Health (CADTH) that develops recommendations on health technology assessments (HTAs) for nondrug health technologies using a deliberative framework. The framework spans several domains, including the environmental impact of the health technology(ies). Our research objective was to identify articles on frameworks, methods or case studies on the environmental impact assessment of health technologies. A literature search in major databases and a focused gray literature search were conducted. The main search concepts were HTA and environmental impact/sustainability. Eligible articles were those that described a conceptual framework or methods used to conduct an environmental assessment of health technologies, and case studies on the application of an environmental assessment. From the 1,710 citations identified, thirteen publications were included. Two articles presented a framework to incorporate environmental assessment in HTAs. Other approaches described weight of evidence practices and comprehensive and integrated environmental impact assessments. Central themes derived include transparency and repeatability, integration of components in a framework or of evidence into a single outcome, data availability to ensure the accuracy of findings, and familiarity with the approach used. Each framework and methods presented have different foci related to the ecosystem, health economics, or engineering practices. Their descriptions suggested transparency, repeatability, and the integration of components or of evidence into a single outcome as their main strengths. Our review is an initial step of a larger initiative by CADTH to develop the methods and processes to address the environmental impact question in an HTA.

  16. Assessment of testicular volume: A comparison of fertile and sub ...

    African Journals Online (AJOL)

    K.H. Tijani

    Eleven of them also had an SFA available (which were normal) while in 89 it was based on history alone. Approval for the study was granted by the hospital research and ethics board, and the informed consent was taken from all subjects. Assessment of testicular volume. Aloka Prosound SDD-3500 Plus, Japan 2005 scan ...

  17. Ultrasound assessment of thyroid gland volume in diabetic patients without overt thyroid disease.

    Science.gov (United States)

    Nduka, Christopher C; Adeyekun, Ademola A

    2016-01-01

    Diabetes mellitus and thyroid disease are known to mutually influence each other. Thyroid disease can worsen glycaemic control in diabetes, and patients with diabetes mellitus have increased incidence of thyroid disorders such as increase in size, compared to the normal population. The aim of the study was to sonographically assess thyroid gland volume in Nigerian adult diabetic patients and compare with apparently healthy adults (controls). The study setting was the Department of Radiology, University of Benin Teaching Hospital (UBTH) Nigeria. The thyroid gland in 120 diabetic subjects and equal number of apparently healthy controls was scanned with a 5-12 MHz linear transducer of a SONOACE X4 Machine. Thyroid gland volume was assessed. Statistical analysis was done with Statistical Package for the Social Sciences (SPSS) version 17 (SPSS Inc, Chicago, IL, USA). Diabetics had significantly increased thyroid volume compared to age matched male and female control subjects (11.5 ± 5.2 cm3 vs 7.4 ± 1.9 cm3; Pthyroid volume among diabetics. Diabetics have higher thyroid gland dimensions, compared to apparently healthy subjects. Gland proliferation from circulating insulin may play a role. This is not influenced by gender.

  18. Probabilistic accident consequence uncertainty analysis: Food chain uncertainty assessment. Volume 1: Main report

    Energy Technology Data Exchange (ETDEWEB)

    Brown, J. [National Radiological Protection Board (United Kingdom); Goossens, L.H.J.; Kraan, B.C.P. [Delft Univ. of Technology (Netherlands)] [and others

    1997-06-01

    This volume is the first of a two-volume document that summarizes a joint project conducted by the US Nuclear Regulatory Commission and the European Commission to assess uncertainties in the MACCS and COSYMA probabilistic accident consequence codes. These codes were developed primarily for estimating the risks presented by nuclear reactors based on postulated frequencies and magnitudes of potential accidents. This document reports on an ongoing project to assess uncertainty in the MACCS and COSYMA calculations for the offsite consequences of radionuclide releases by hypothetical nuclear power plant accidents. A panel of sixteen experts was formed to compile credible and traceable uncertainty distributions for food chain variables that affect calculations of offsite consequences. The expert judgment elicitation procedure and its outcomes are described in these volumes. Other panels were formed to consider uncertainty in other aspects of the codes. Their results are described in companion reports. Volume 1 contains background information and a complete description of the joint consequence uncertainty study. Volume 2 contains appendices that include (1) a summary of the MACCS and COSYMA consequence codes, (2) the elicitation questionnaires and case structures for both panels, (3) the rationales and results for the panels on soil and plant transfer and animal transfer, (4) short biographies of the experts, and (5) the aggregated results of their responses.

  19. Probabilistic accident consequence uncertainty analysis: Food chain uncertainty assessment. Volume 1: Main report

    International Nuclear Information System (INIS)

    Brown, J.; Goossens, L.H.J.; Kraan, B.C.P.

    1997-06-01

    This volume is the first of a two-volume document that summarizes a joint project conducted by the US Nuclear Regulatory Commission and the European Commission to assess uncertainties in the MACCS and COSYMA probabilistic accident consequence codes. These codes were developed primarily for estimating the risks presented by nuclear reactors based on postulated frequencies and magnitudes of potential accidents. This document reports on an ongoing project to assess uncertainty in the MACCS and COSYMA calculations for the offsite consequences of radionuclide releases by hypothetical nuclear power plant accidents. A panel of sixteen experts was formed to compile credible and traceable uncertainty distributions for food chain variables that affect calculations of offsite consequences. The expert judgment elicitation procedure and its outcomes are described in these volumes. Other panels were formed to consider uncertainty in other aspects of the codes. Their results are described in companion reports. Volume 1 contains background information and a complete description of the joint consequence uncertainty study. Volume 2 contains appendices that include (1) a summary of the MACCS and COSYMA consequence codes, (2) the elicitation questionnaires and case structures for both panels, (3) the rationales and results for the panels on soil and plant transfer and animal transfer, (4) short biographies of the experts, and (5) the aggregated results of their responses

  20. Factors controlling volume errors through 2D gully erosion assessment: guidelines for optimal survey design

    Science.gov (United States)

    Castillo, Carlos; Pérez, Rafael

    2017-04-01

    The assessment of gully erosion volumes is essential for the quantification of soil losses derived from this relevant degradation process. Traditionally, 2D and 3D approaches has been applied for this purpose (Casalí et al., 2006). Although innovative 3D approaches have recently been proposed for gully volume quantification, a renewed interest can be found in literature regarding the useful information that cross-section analysis still provides in gully erosion research. Moreover, the application of methods based on 2D approaches can be the most cost-effective approach in many situations such as preliminary studies with low accuracy requirements or surveys under time or budget constraints. The main aim of this work is to examine the key factors controlling volume error variability in 2D gully assessment by means of a stochastic experiment involving a Monte Carlo analysis over synthetic gully profiles in order to 1) contribute to a better understanding of the drivers and magnitude of gully erosion 2D-surveys uncertainty and 2) provide guidelines for optimal survey designs. Owing to the stochastic properties of error generation in 2D volume assessment, a statistical approach was followed to generate a large and significant set of gully reach configurations to evaluate quantitatively the influence of the main factors controlling the uncertainty of the volume assessment. For this purpose, a simulation algorithm in Matlab® code was written, involving the following stages: - Generation of synthetic gully area profiles with different degrees of complexity (characterized by the cross-section variability) - Simulation of field measurements characterised by a survey intensity and the precision of the measurement method - Quantification of the volume error uncertainty as a function of the key factors In this communication we will present the relationships between volume error and the studied factors and propose guidelines for 2D field surveys based on the minimal survey

  1. Inventory of Federal energy-related environment and safety research for FY 1979. Volume 1. Executive summary

    International Nuclear Information System (INIS)

    1980-12-01

    The FY 1979 Federal Inventory contains information on 3506 federally funded energy-related environmental and safety research projects. The Inventory is published in two volumes: Volume I, an executive summary and overview of the data and Volume II, project listings, summaries, and indexes. Research and development (R and D) categories were reorganized into three main areas; environmental and safety control technology, technology impacts overview and assessments, and biological and environmental R and D and assessments. Federal offices submitting project data were: Council on Environmental Quality; Department of Agriculture; Department of Commerce; Department of Defense; Department of Energy; Department of Health, Education, and Welfare; Department of Housing and Urban Development; Department of the Interior; Department of Transportation; Environmental Protection Agency; National Aeronautics and Space Administration; Nuclear Regulatory Commission; National Science Foundation; Office of Technology Assessment; and Tennessee Valley Authority. The inventory also breaks out research sponsored by various federal agencies and the amount of funding provided by each in various research categories. The format and index system allows efficient access to information compiled. Users are able to identify projects by log agency, performing organization, principal investigator and subject

  2. Comparative assessment of TRU waste forms and processes. Volume II. Waste form data, process descriptions, and costs

    International Nuclear Information System (INIS)

    Ross, W.A.; Lokken, R.O.; May, R.P.; Roberts, F.P.; Thornhill, R.E.; Timmerman, C.L.; Treat, R.L.; Westsik, J.H. Jr.

    1982-09-01

    This volume contains supporting information for the comparative assessment of the transuranic waste forms and processes summarized in Volume I. Detailed data on the characterization of the waste forms selected for the assessment, process descriptions, and cost information are provided. The purpose of this volume is to provide additional information that may be useful when using the data in Volume I and to provide greater detail on particular waste forms and processes. Volume II is divided into two sections and two appendixes. The first section provides information on the preparation of the waste form specimens used in this study and additional characterization data in support of that in Volume I. The second section includes detailed process descriptions for the eight processes evaluated. Appendix A lists the results of MCC-1 leach test and Appendix B lists additional cost data. 56 figures, 12 tables

  3. Where’s the Transformation? Unlocking the Potential of Technology-Enhanced Assessment

    Directory of Open Access Journals (Sweden)

    Trudy Sweeney

    2017-03-01

    Full Text Available This study provides insight into technology-enhanced assessment (TEA in diverse higher education contexts. The effectiveness of using technology for assessment in higher education is still equivocal, particularly in regard to evidence of improvements in student learning. This empirical research explores the affordances that technology offers to assessment for transforming student learning. A systematic literature review, guided by an analytic survey tool, was used to identify and interrogate recent scholarly articles published in 19 international journals. From a total of 1713 articles, 139 articles were identified as being focused on the use of technology for assessment. The analytic tool guided the rigorous exploration of the literature regarding the types of technology being used, the educational goal, the type of assessment, and the degree of “transformation” afforded by the technology. Results showed that, in the sample investigated, TEA is used most frequently for formative peer learning, as part of the task design and feedback stages of the assessment cycle, and that social media has been a major affordance for this. Results are discussed with a view to fostering a future culture of inquiry and scholarship around TEA in higher education.

  4. The Fukushima Daiichi Accident. Technical Volume 2/5. Safety Assessment

    International Nuclear Information System (INIS)

    2015-08-01

    Technical Volume 1 of this report has described what happened during the accident at the Fukushima Daiichi nuclear power plant (NPP). This volume begins (Section 2.1) with a review of how the design basis of the site for external events was assessed initially and then reassessed over the life of the NPP. The section also describes the physical changes that were made to the units as a result. The remainder of the volume describes the treatment of beyond design basis events in the safety assessment of the site, the accident management provisions, the effectiveness of regulatory programmes, human and organizational factors and the safety culture, and the role of operating experience. Further background information is contained in three annexes included on the CD-ROM of this Technical Volume which describe analytical investigations of the accident along with information on topics such as system performance, defence in depth and severe accident phenomena. Section 2.2 provides an assessment of the systems that failed, resulting in a failure to maintain the fundamental safety functions in Units 1–3, which were in operation at the time of the tsunami and in which the reactor pressure vessels (RPV) and containment vessels failed. The section also describes Units 4-6, which were shut down at the time of the tsunami, and the site’s central spent fuel storage facility. Section 2.3 discusses the probabilistic and deterministic safety assessments of beyond design basis accidents (BDBAs) that had been performed for the plant and the insights from these assessments that had led to changes in the plant’s design. The section pays particular attention to the assessment of extreme natural hazards, such as the one which led to the total loss of AC power supply on the site. The additional loss of DC power supply in Units 1 and 2 played a key role in the progression of the accident because it impeded the diagnosis of plant conditions and made the operators unaware of the status of

  5. Current state of the technology measures of accident from contamination by the radioactive substance. 4. volume reduction of removing soil treatment technology

    International Nuclear Information System (INIS)

    Ito, Kenichi

    2015-01-01

    The removed materials that were generated via decontamination work and contaminated with radioactive cesium are mainly soil, the total amount of which is estimated at about 16 million to 22 million m3 in Fukushima Prefecture. Since cesium 137 has a short half-life of 30 years, the amount that needs final disposal after 30 years is expected to be 6 million m3 plus. In order to rationally and safely promote the transport, storage, and disposal of removed contaminants, volume reduction as much as possible is important, which requires relevant techniques. The biggest challenge of the volume reduction is an appropriate use of a low concentration of or purified/reproduced soil that occurs in the process. Since the recycled soil is not completely consumed only by intermediate processing facilities, there is a possibility to be used at outside facilities. There are needs for the tests and securement of qualities and standards according to the application, as well as the empirical data of practicality and long-term safety. It includes not only technical problem-solving, technology dissemination, and standardization, but also the construction of social acceptability. To do this, it is important that researchers and engineers in many fields in addition to those of soil jointly own common agenda and perform cross-cutting initiatives. After this, the social acceptance of volume reduction technology and the treatment of decontaminated waste would make a progress. (A.O.)

  6. Aerospace Technology Innovation. Volume 9

    Science.gov (United States)

    Turner, Janelle (Editor); Cousins, Liz (Editor)

    2001-01-01

    Commercializing technology is a daunting task. Of every 11 new product ideas, only one will successfully make it to the marketplace. Fully 46% of new product investment becomes sunk in cost. Yet, a few good companies consistently attain an 80% technology commercialization success rate and have lead the way in establishing best practices. The NASA Incubator program consists of nine incubators, each residing near a NASA research center. The purpose of the incubators is to use the best practices is to use the best practices of technology commercialization to help early stage businesses successfully launch new products that incorporate NASA technology.

  7. Fifth DOE symposium on enhanced oil and gas recovery and improved drilling technology. Volume 3. Gas and drilling

    Energy Technology Data Exchange (ETDEWEB)

    Linville, B. [ed.

    1979-01-01

    Volume 3 contains papers from the sessions on natural gas supporting research, western gas sands project, drilling technology, and environmental effects. Individuals were processed for inclusion in the Energy Data Base.

  8. US Department of Energy interim mixed waste inventory report: Waste streams, treatment capacities and technologies: Volume 6, Appendices

    International Nuclear Information System (INIS)

    1993-04-01

    This volume contains Appendix A--Federal Facility Compliance Act of 1992, Appendix B--Technology Development, and Appendix C--Other Materials. Appendix B supplies details concerning the technology development activities supported by DOE in the area of mixed waste management. Two parts of this appendix are important. The more important of the two is the collection of technology development summaries. There are 267 summaries collected from several sources, which are described. The second important part consists of tables which group technologies by one several attributes such as target site and cross-complex applicability as well as relationship to Resource Conservation Recovery Act Best Demonstrated Available Technologies (RCRA BDATs)

  9. Pore volume is most highly correlated with the visual assessment of skin pores.

    Science.gov (United States)

    Kim, S J; Shin, M K; Back, J H; Koh, J S

    2014-11-01

    Many studies have been focused on evaluating assessment techniques for facial pores amid growing attention on skin care. Ubiquitous techniques used to assess the size of facial pores include visual assessment, cross-section images of the skin surface, and profilometric analysis of silicone replica of the facial skin. In addition, there are indirect assessment methods, including observation of pores based on confocal laser scanning microscopy and the analysis of sebum secretion and skin elasticity. The aim of this study was to identify parameters useful in estimating pore of surface in normal skin. The severity of pores on the cheek area by frontal optical images was divided on a 0-6 scale with '0' being faint and small pore and '6' being obvious and large pore. After the photos of the frontal cheek of 32 women aged between 35 and 49 were taken, the size of their pores was measured on a 0-6 scale; and the correlation between visual grading of pore and various evaluations (pore volume by 3-D image, pore area and number by Optical Image Analyzer) contributing to pore severity investigated using direct, objective, and noninvasive evaluations. The visual score revealed that the size of pores was graded on a 1-6 scale. Visual grading of pore was highly correlated with pore volume measured from 3-D images and pore area measured from 2-D optical images in the order (P pore was also slightly correlated with the number of pores in size of over 0.04 mm(2) (P pore score and pore volume can be explained by 3-D structural characteristics of pores. It is concluded that pore volume and area serve as useful parameters in estimating pore of skin surface. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Radioactive scrap metal decontamination technology assessment report

    International Nuclear Information System (INIS)

    Buckentin, J.M.; Damkroger, B.K.; Schlienger, M.E.

    1996-04-01

    Within the DOE complex there exists a tremendous quantity of radioactive scrap metal. As an example, it is estimated that within the gaseous diffusion plants there exists in excess of 700,000 tons of contaminated stainless steel. At present, valuable material is being disposed of when it could be converted into a high quality product. Liquid metal processing represents a true recycling opportunity for this material. By applying the primary production processes towards the material's decontamination and re-use, the value of the strategic resource is maintained while drastically reducing the volume of material in need of burial. Potential processes for the liquid metal decontamination of radioactively contaminated metal are discussed and contrasted. Opportunities and technology development issues are identified and discussed. The processes compared are: surface decontamination; size reduction, packaging and burial; melting technologies; electric arc melting; plasma arc centrifugal treatment; air induction melting; vacuum induction melting; and vacuum induction melting and electroslag remelting

  11. Expanding the applicability of Heallth Technology Assessments

    DEFF Research Database (Denmark)

    Draborg, Eva; Hansen, Helle Ploug

    2012-01-01

    The objective of the presentation is to expand the foundations of input into policy decision making relying on health technology assessments (HTA). HTAs are primarily based on systematic reviews (SR) and thereby mostly on randomized controlled trials (RCT). RCTs can be distinguished on a continuum...... between explanatory and pragmatic trials according to their level of control over variables in the study besides the examined technology. In explanatory trials emphasis are placed on internal validity in order to test the efficacy of a technology under ideal conditions while pragmatic trials emphasizes...... external validity and the effectiveness of a technology in normal daily practice. SR and HTAs favors internal valid trials and thereby proofs of possible cause-effect relationship between a technology and outcomes but at the expense of the wider perspectives of a technology. HTA have a policy...

  12. Reactor technology assessment and selection utilizing systems engineering approach

    Science.gov (United States)

    Zolkaffly, Muhammed Zulfakar; Han, Ki-In

    2014-02-01

    The first Nuclear power plant (NPP) deployment in a country is a complex process that needs to consider technical, economic and financial aspects along with other aspects like public acceptance. Increased interest in the deployment of new NPPs, both among newcomer countries and those with expanding programs, necessitates the selection of reactor technology among commercially available technologies. This paper reviews the Systems Decision Process (SDP) of Systems Engineering and applies it in selecting the most appropriate reactor technology for the deployment in Malaysia. The integrated qualitative and quantitative analyses employed in the SDP are explored to perform reactor technology assessment and to select the most feasible technology whose design has also to comply with the IAEA standard requirements and other relevant requirements that have been established in this study. A quick Malaysian case study result suggests that the country reside with PWR (pressurized water reactor) technologies with more detailed study to be performed in the future for the selection of the most appropriate reactor technology for Malaysia. The demonstrated technology assessment also proposes an alternative method to systematically and quantitatively select the most appropriate reactor technology.

  13. Assessment of selected furnace technologies for RWMC waste

    International Nuclear Information System (INIS)

    Batdorf, J.; Gillins, R.; Anderson, G.L.

    1992-03-01

    This report provides a description and initial evaluation of five selected thermal treatment (furnace) technologies, in support of earlier thermal technologies scoping work for application to the Idaho National Engineering Laboratory Radioactive Waste Management Complex (RWMC) buried wastes. The cyclone furnace, molten salt processor, microwave melter, ausmelt (fuel fired lance) furnace, and molten metal processor technologies are evaluated. A system description and brief development history are provided. The state of development of each technology is assessed, relative to treatment of RWMC buried waste

  14. Advanced power assessment for Czech lignite. Task 3.6, Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Sondreal, E.A.; Mann, M.D.; Weber, G.W.; Young, B.C.

    1995-12-01

    The US has invested heavily in research, development, and demonstration of efficient and environmentally acceptable technologies for the use of coal. The US has the opportunity to use its leadership position to market a range of advanced coal-based technologies internationally. For example, coal mining output in the Czech Republic has been decreasing. This decrease in demand can be attributed mainly to the changing structure of the Czech economy and to environmental constraints. The continued production of energy from indigenous brown coals is a major concern for the Czech Republic. The strong desire to continue to use this resource is a challenge. The Energy and Environmental Research Center undertook two major efforts recently. One effort involved an assessment of opportunities for commercialization of US coal technologies in the Czech Republic. This report is the result of that effort. The technology assessment focused on the utilization of Czech brown coals. These coals are high in ash and sulfur, and the information presented in this report focuses on the utilization of these brown coals in an economically and environmentally friendly manner. Sections 3--5 present options for utilizing the as-mined coal, while Sections 6 and 7 present options for upgrading and generating alternative uses for the lignite. Contents include Czech Republic national energy perspectives; powering; emissions control; advanced power generation systems; assessment of lignite-upgrading technologies; and alternative markets for lignite.

  15. How to make participatory technology assessment in agriculture more 'participatory'

    DEFF Research Database (Denmark)

    Tavella, Elena

    2016-01-01

    the cultivation of new GM plants in Denmark. Furthermore, through this illustration, the term Participatory Technology Assessment (PTA) is redefined, thereby suggesting two additional aspects to assessing new technologies – following and evaluating policy making – to be considered in the conduct of PTA....

  16. Technology-Enhanced Formative Assessment: A Research-Based Pedagogy for Teaching Science with Classroom Response Technology

    Science.gov (United States)

    Beatty, Ian D.; Gerace, William J.

    2009-01-01

    "Classroom response systems" (CRSs) are a promising instructional technology, but most literature on CRS use fails to distinguish between technology and pedagogy, to define and justify a pedagogical perspective, or to discriminate between pedagogies. "Technology-enhanced formative assessment" (TEFA) is our pedagogy for CRS-based science…

  17. 9th Pacific Basin Nuclear Conference. Nuclear energy, science and technology - Pacific partnership. Proceedings Volume 2

    International Nuclear Information System (INIS)

    1994-04-01

    The theme of the 9th Pacific Basin Nuclear Conference held in Sydney from 1-6 May 1994, embraced the use of atom in energy production and in science and technology. The focus was on selected topics of current and on-going interest to countries around the Pacific Basin. The two-volume proceedings include both invited and contributed papers which have been indexed separately. This document, Volume 2 covers the following topics: education and training in Nuclear Science, public acceptance, nuclear safety and radiation protection, nuclear fuel resources and their utilisation, research reactors, cyclotrons and accelerators. refs., tabs., figs., ills

  18. Technology assessment - a workable way out of the 'risk society'?

    International Nuclear Information System (INIS)

    Mueller-Brandeck-Bocquet, G.

    1988-01-01

    On the basis of concrete experience and results in the risk assessment process concerning nuclear technology in the Federal Republic of Germany it becomes apparent that technology asessment can make a contribution towards the required technology domestication. The 'risk management' of the circle of nuclear power generators and the consulting and licensing bodies having failed, a new phase of technology assessment began in 1970, whereby proponents and opponents of nuclear energy had a say. Parallel research on the safety of light water reactors and fast breeders gave valuable insight into the danger potential of nuclear energy while the latent risk of technology assessment misuse became apparent in the decision-finding process concerning the problem of radioactive waste management. In the end it were the Enquete Commission 'Future Nuclear Energy Policy' of the German Bundestag and the studies on social agreeability of energy supply systems which resulted in the perspective of a future without the use of nuclear power being a realistic option. The general findings of technology assessment, e.g. the cognition that there can be no scientific decision in favour of assuming responsibility for nuclear energy, opens up new views and possibilities for acting for the decision-makers in the field of energy policy. (orig./HSCH) [de

  19. Technology assessment of future intercity passenger transporation systems. Volume 2: Identification of issues affecting intercity transportation

    Science.gov (United States)

    1976-01-01

    Papers on major issues and trends that affect the future of intercity transportation are presented. Specific areas covered include: political, social, technological, institutional, and economic mechanisms, the workings of which determine how future intercity transporation technologies will evolve and be put into service; the major issues of intercity transportation from the point of view of reform, including candidate transporation technologies; and technical analysis of trends affecting the evolution of intercity transportation technologies.

  20. Enhancing economic competiveness of dish Stirling technology through production volume and localization: Case study for Morocco

    Science.gov (United States)

    Larchet, Kevin; Guédez, Rafael; Topel, Monika; Gustavsson, Lars; Machirant, Andrew; Hedlund, Maria-Lina; Laumert, Björn

    2017-06-01

    The present study quantifies the reduction in the levelized cost of electricity (LCoE) and capital expenditure (CAPEX) of a dish Stirling power plant (DSPP) through an increase in localization and unit production volume. Furthermore, the localization value of the plant is examined to determine how much investment is brought into the local economy. Ouarzazate, Morocco, was chosen as the location of the study due to the country's favorable regulatory framework with regards to solar power technologies and its established industry in the concentrating solar power (CSP) field. A detailed techno-economic model of a DSPP was developed using KTH's in-house modelling tool DYESOPT, which allows power plant evaluation by means of technical and economic performance indicators. Results on the basis of LCoE and CAPEX were compared between two different cases of production volume, examining both a minimum and maximum level of localization. Thereafter, the DSPP LCoE and localization value were compared against competing solar technologies to evaluate its competitiveness. In addition, a sensitivity analysis was conducted around key design parameters. The study confirms that the LCoE of a DSPP can be reduced to values similar to solar photovoltaic (PV) and lower than other CSP technologies. Furthermore, the investment in the local economy is far greater when compared to PV and of the same magnitude to other CSP technologies. The competiveness of a DSPP has the potential to increase further when coupled with thermal energy storage (TES), which is currently under development.

  1. Assessment of Sensor Technologies for Advanced Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Korsah, Kofi [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ramuhalli, Pradeep [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Vlim, R. [Argonne National Lab. (ANL), Argonne, IL (United States); Kisner, Roger A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Britton, Jr, Charles L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Wootan, D. W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Anheier, Jr, N. C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Diaz, A. A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hirt, E. H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chien, H. T. [Argonne National Lab. (ANL), Argonne, IL (United States); Sheen, S. [Argonne National Lab. (ANL), Argonne, IL (United States); Bakhtiari, Sasan [Argonne National Lab. (ANL), Argonne, IL (United States); Gopalsami, S. [Argonne National Lab. (ANL), Argonne, IL (United States); Heifetz, A. [Argonne National Lab. (ANL), Argonne, IL (United States); Tam, S. W. [Argonne National Lab. (ANL), Argonne, IL (United States); Park, Y. [Argonne National Lab. (ANL), Argonne, IL (United States); Upadhyaya, B. R. [Univ. of Tennessee, Knoxville, TN (United States); Stanford, A. [Univ. of Tennessee, Knoxville, TN (United States)

    2016-10-01

    Sensors and measurement technologies provide information on processes, support operations and provide indications of component health. They are therefore crucial to plant operations and to commercialization of advanced reactors (AdvRx). This report, developed by a three-laboratory team consisting of Argonne National Laboratory (ANL), Oak Ridge National Laboratory (ORNL) and Pacific Northwest National Laboratory (PNNL), provides an assessment of sensor technologies and a determination of measurement needs for AdvRx. It provides the technical basis for identifying and prioritizing research targets within the instrumentation and control (I&C) Technology Area under the Department of Energy’s (DOE’s) Advanced Reactor Technology (ART) program and contributes to the design and implementation of AdvRx concepts.

  2. Zero-emission vehicle technology assessment. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Woods, T.

    1995-08-01

    This is the final report in the Zero-Emission Vehicle (ZEV) Technology Assessment, performed for NYSERDA by Booz-Allen & Hamilton Inc. Booz-Allen wrote the final report, and performed the following tasks as part of the assessment: assembled a database of key ZEV organizations, their products or services, and plans; described the current state of ZEV technologies; identified barriers to widespread ZEV deployment and projected future ZEV technical capabilities; and estimated the cost of ZEVs from 1998 to 2004. Data for the ZEV Technology Assessment were obtained from several sources, including the following: existing ZEV industry publications and Booz-Allen files; major automotive original equipment manufacturers; independent electric vehicle manufacturers; battery developers and manufacturers; infrastructure and component developers and manufacturers; the U.S. Department of Energy, the California Air Resources Board, and other concerned government agencies; trade associations such as the Electric Power Research Institute and the Electric Transportation Coalition; and public and private consortia. These sources were contacted by phone, mail, or in person. Some site visits of manufacturers also were conducted. Where possible, raw data were analyzed by Booz-Allen staff and/or verified by independent sources. Performance data from standardized test cycles were used as much as possible.

  3. Economical-environmental assessment on technologies producing electric energy

    International Nuclear Information System (INIS)

    Najafzadeh, K.

    2000-01-01

    Currently, the electric power industry is undergoing substantial regulatory and organizational change with respect to economical and environmental aspects. Under these circumstances, with utilization of analytic hierarchy process (AHP) concept, we consider the assessment of Technologies producing energy from financial and pollution viewpoint. AHP techniques is one of the efficient methods in analysis of complex and multi-criteria problems, which has plenty of applications. General pattern of this assessment has been introduced, and the main goal is determining of overall priority weights for each technology. With using this pattern, overall priority weights has been determined for thermal, combined cycle and Gas turbine plants. It has been cleared that relative priority of these plants will change, if relative priority of assessment criterions changes. For application of this approach, capital budgeting process and selection of some suitable technologies among the alternatives candidate for construction have been presented. In this process the objective is to maximize the sum of overall priority weights of technologies which have been identified from AHP. Constraints are about the construction budget and annual budget for emission allowances. This process is in the integer programming IP form an has been applied to three kind of power plants with reasonable assumptions

  4. Multiple criteria decision analysis for health technology assessment.

    Science.gov (United States)

    Thokala, Praveen; Duenas, Alejandra

    2012-12-01

    Multicriteria decision analysis (MCDA) has been suggested by some researchers as a method to capture the benefits beyond quality adjusted life-years in a transparent and consistent manner. The objectives of this article were to analyze the possible application of MCDA approaches in health technology assessment and to describe their relative advantages and disadvantages. This article begins with an introduction to the most common types of MCDA models and a critical review of state-of-the-art methods for incorporating multiple criteria in health technology assessment. An overview of MCDA is provided and is compared against the current UK National Institute for Health and Clinical Excellence health technology appraisal process. A generic MCDA modeling approach is described, and the different MCDA modeling approaches are applied to a hypothetical case study. A comparison of the different MCDA approaches is provided, and the generic issues that need consideration before the application of MCDA in health technology assessment are examined. There are general practical issues that might arise from using an MCDA approach, and it is suggested that appropriate care be taken to ensure the success of MCDA techniques in the appraisal process. Copyright © 2012 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  5. Viability Assessment Volume 2

    International Nuclear Information System (INIS)

    1998-01-01

    This volume describes the major design features of the Monitored Geologic Repository. This document is not intended to provide an exhaustive, detailed description of the repository design. Rather, this document summarizes the major systems and primary elements of the design that are radiologically significant, and references the specific technical documents and design analyses wherein the details can be found. Not all portions of the design are at the same level of completeness. Highest priority has been given to assigning resources to advance the design of the Monitored Geologic Repository features that are important to radiological safety and/or waste isolation and for which there is no NRC licensing precedent. Those features that are important to radiological safety and/or waste isolation, but for which there is an NRC precedent, receive second priority. Systems and features that have no impact on radiological safety or waste isolation receive the lowest priority. This prioritization process, referred to as binning, is discussed in more detail in Section 2.3. Not every subject discussed in this volume is given equal treatment with regard to the level of detail provided. For example, less detail is provided for the surface facility design than for the subsurface and waste package designs. This different level of detail is intentional. Greater detail is provided for those functions, structures, systems, and components that play key roles with regard to protecting radiological health and safety and that are not common to existing nuclear facilities already licensed by NRC. A number of radiological subjects are not addressed in the VA, (e.g., environmental qualification of equipment). Environmental qualification of equipment and other radiological safety considerations will be addressed in the LA. Non-radiological safety considerations such as silica dust control and other occupational safety considerations are considered equally important but are not addressed in

  6. Assessment vs. appraisal of ethical aspects of health technology assessment: can the distinction be upheld?

    Directory of Open Access Journals (Sweden)

    Sandman, Lars

    2014-11-01

    Full Text Available [english] An essential component of health technology assessment (HTA is the assessment of ethical aspects. In some healthcare contexts, tasks are strictly relegated to different expert groups: the HTA-agencies are limited to assessment of the technology and other actors within the health care sector are responsible for appraisal and recommendations. Ethical aspects of health technologies are considered with reference to values or norms in such a way that may be prescriptive, or offer guidance as to how to act or relate to the issue in question. Given this internal prescriptivity, the distinction between assessment and appraisal seems difficult to uphold, unless the scrutiny stops short of a full ethical analysis of the technology. In the present article we analyse the distinction between assessment and appraisal, using as an example ethical aspects of implementation of GPS-bracelets for people with dementia. It is concluded that for HTA-agencies with a strictly delineated assessment role, the question of how to deal with the internal prescriptivity of ethics may be confusing. A full ethical analysis might result in a definite conclusion as to whether the technology in question is ethically acceptable or not, thereby limiting choices for decision-makers, who are required to uphold certain ethical values and norms. At the same time, depending on the exact nature of such a conclusion, different action strategies can be supported. A positive appraisal within HTA could result in a decision on implementation, or of the technology, thereby making it available to patients, or decisions to and even the use of the technology (even if someone else will have to fund it. A neutral appraisal, giving no definite answer as to whether implementation is recommended or not, could result in a towards the technology. A negative appraisal could result in a decision to or even implementation. This paper presents an overview of the implications of different outcomes

  7. Rapid Technology Assessment Framework for Land Logistics

    Science.gov (United States)

    2015-03-01

    Economy, Environment, Politics SWOT Strengths, Weaknesses, Opportunities, Threats TRL Technology Readiness Level US United States WHO World Health...process fills one with the hope of great things to come. From 3-D printed organs to self-assembling asteroid -mining robots, the solution to all the...one to assess the relevant advantages of the new technologies compared to the current systems. For example, if we are considering investment in a

  8. Health technology assessment in Mexico.

    Science.gov (United States)

    Gómez-Dantés, Octavio; Frenk, Julio

    2009-07-01

    The history of health technology assessment (HTA) in Mexico is examined, starting with the efforts to incorporate this topic into the policy agenda and culminating with the recent creation of a specialized public agency. Information was gathered through a bibliographic search and interviews with actors involved in HTA in Mexico. HTA efforts were developed in Mexico since the mid-1980s with the participation both of academics and of policy makers, a relationship that eventually led to the creation of the Center for Technological Excellence within the Ministry of Health. Institutionalization of HTA in resource-constrained settings requires the development of a critical mass of researchers involved in this field, the implementation of information efforts, and the establishment of strong relationships between HTA experts and policy makers.

  9. SITE TECHNOLOGY CAPSULE: DYNAPHORE, INC., FORAGER SPONGE TECHNOLOGY

    Science.gov (United States)

    The Forager Sponge is a volume reduction technology in which heavy metal contaminants from an aqueous medium are selectively concentrated into a smaller volume for facilitated disposal. he technology treats contaminated groundwater, surface waters and porous waters by absorbing d...

  10. SITE TECHNOLOGY CAPSULE: DYNAPHORE, INC., FORAGER™ SPONGE TECHNOLOGY

    Science.gov (United States)

    The Forager™ Sponge is a volume reduction technology in which heavy metal contaminants from an aqueous medium are selectively concentrated into a smaller volume for facilitated disposal. The technology treats contaminated groundwater, surface waters, and process waters by absorbi...

  11. Q46 Technology Refreshment Assessment

    Science.gov (United States)

    Garcia-Burgos, Axel A.

    2010-01-01

    This document reviews the accomplishments of the author during an internship. During this internship, the author was assigned to the End User Services Office, which coordinates and oversees a wide selection of information technologies that enhance the productivity of the workforce at NASA Kennedy Space Center. During the internship the author performed an assessment of the work of the Outsourcing Desktop Initiative for NASA (ODIN) contract.

  12. Conventional engine technology. Volume 3: Comparisons and future potential

    Science.gov (United States)

    Dowdy, M. W.

    1981-01-01

    The status of five conventional automobile engine technologies was assessed and the future potential for increasing fuel economy and reducing exhaust emission was discussed, using the 1980 EPA California emisions standards as a comparative basis. By 1986, the fuel economy of a uniform charge Otto engine with a three-way catalyst is expected to increase 10%, while vehicles with lean burn (fast burn) engines should show a 20% fuel economy increase. Although vehicles with stratified-charge engines and rotary engines are expected to improve, their fuel economy will remain inferior to the other engine types. When adequate NO emissions control methods are implemented to meet the EPA requirements, vehicles with prechamber diesel engines are expected to yield a fuel economy advantage of about 15%. While successful introduction of direct injection diesel engine technology will provide a fuel savings of 30 to 35%, the planned regulation of exhaust particulates could seriously hinder this technology, because it is expected that only the smallest diesel engine vehicles could meet the proposed particulate requirements.

  13. Organizational analysis and safety for utilities with nuclear power plants: perspectives for organizational assessment. Volume 2

    International Nuclear Information System (INIS)

    Osborn, R.N.; Olson, J.; Sommers, P.E.

    1983-08-01

    This two-volume report presents the results of initial research on the feasibility of applying organizational factors in nuclear power plant (NPP) safety assessment. Volume 1 of this report contains an overview of the literature, a discussion of available safety indicators, and a series of recommendations for more systematically incorporating organizational analysis into investigations of nuclear power plant safety. The six chapters of this volume discuss the major elements in our general approach to safety in the nuclear industry. The chapters include information on organizational design and safety; organizational governance; utility environment and safety related outcomes; assessments by selected federal agencies; review of data sources in the nuclear power industry; and existing safety indicators

  14. Predicted stand volume for Eucalyptus plantations by spatial analysis

    Science.gov (United States)

    Latifah, Siti; Teodoro, RV; Myrna, GC; Nathaniel, CB; Leonardo, M. F.

    2018-03-01

    The main objective of the present study was to assess nonlinear models generated by integrating the stand volume growth rate to estimate the growth and yield of Eucalyptus. The primary data was done for point of interest (POI) of permanent sample plots (PSPs) and inventory sample plots, in Aek Nauli sector, Simalungun regency,North Sumatera Province,Indonesia. from December 2008- March 2009. Today,the demand for forestry information has continued to grow over recent years. Because many forest managers and decision makers face complex decisions, reliable information has become the necessity. In the assessment of natural resources including plantation forests have been widely used geospatial technology.The yield of Eucalyptus plantations represented by merchantable volume as dependent variable while factors affecting yield namely stands variables and the geographic variables as independent variables. The majority of the areas in the study site has stand volume class 0 - 50 m3/ha with 16.59 ha or 65.85 % of the total study site.

  15. Risk-based systems analysis for emerging technologies: Applications of a technology risk assessment model to public decision making

    International Nuclear Information System (INIS)

    Quadrel, M.J.; Fowler, K.M.; Cameron, R.; Treat, R.J.; McCormack, W.D.; Cruse, J.

    1995-01-01

    The risk-based systems analysis model was designed to establish funding priorities among competing technologies for tank waste remediation. The model addresses a gap in the Department of Energy's (DOE's) ''toolkit'' for establishing funding priorities among emerging technologies by providing disciplined risk and cost assessments of candidate technologies within the context of a complete remediation system. The model is comprised of a risk and cost assessment and a decision interface. The former assesses the potential reductions in risk and cost offered by new technology relative to the baseline risk and cost of an entire system. The latter places this critical information in context of other values articulated by decision makers and stakeholders in the DOE system. The risk assessment portion of the model is demonstrated for two candidate technologies for tank waste retrieval (arm-based mechanical retrieval -- the ''long reach arm'') and subsurface barriers (close-coupled chemical barriers). Relative changes from the base case in cost and risk are presented for these two technologies to illustrate how the model works. The model and associated software build on previous work performed for DOE's Office of Technology Development and the former Underground Storage Tank Integrated Demonstration, and complement a decision making tool presented at Waste Management 1994 for integrating technical judgements and non-technical (stakeholder) values when making technology funding decisions

  16. Patrick Air Force Base integrated resource assessment. Volume 3, Resource assessment

    Energy Technology Data Exchange (ETDEWEB)

    Sandusky, W.F.; Parker, S.A.; King, D.A.; Wahlstrom, R.R.; Elliott, D.B.; Shankle, S.A.

    1993-12-01

    The US Air Force has tasked the Pacific Northwest Laboratory (PNL) in support of the US Department of Energy Federal Energy Management Program to identify, evaluate, and assist in acquiring all cost effective energy projects at Patrick Air Force Base (AFB). This is part of a model program that PNL is designing to support energy-use decisions in the federal sector. This report provides the results of the fossil fuel and electric energy resource opportunity (ERO) assessments performed by PNL at Patrick AFB which is located south of Cocoa Beach, Florida. It is a companion report to Volume 1, Executive Summary, and Volume.2, Baseline Detail. The results of the analyses of EROs are presented in 11 common energy end-use categories. A narrative description of each ERO is provided, including information on the installed cost, energy and dollar savings, impacts on operations and maintenance, and, when applicable, a discussion of energy supply and demand, energy security, and environmental issues. A description of the evaluation methodologies and technical and cost assumptions is also provided for each ERO. Summary tables present the cost-effectiveness of energy end-use equipment before and after the implementation of each ERO and present the results of the life-cycle cost analysis indicating the net present value and value index of each ERO.

  17. Field Operations and Enforcement Manual for Air Pollution Control. Volume II: Control Technology and General Source Inspection.

    Science.gov (United States)

    Weisburd, Melvin I.

    The Field Operations and Enforcement Manual for Air Pollution Control, Volume II, explains in detail the following: technology of source control, modification of operations, particulate control equipment, sulfur dioxide removal systems for power plants, and control equipment for gases and vapors; inspection procedures for general sources, fuel…

  18. The NICE ADHD health technology assessment: A review and critique

    Directory of Open Access Journals (Sweden)

    Schlander Michael

    2008-01-01

    Full Text Available Abstract Background Health technology assessments (HTAs by the National Institute for Health and Clinical Excellence (NICE enjoy high levels of international attention. The present analysis addresses NICE's appraisal of methylphenidate, atomoxetine and dexamphetamine for attention-deficit/hyperactivity disorder (ADHD in children and adolescents, published in March 2006. Methods A qualitative study of NICE Technology Appraisal No. 98 was done focusing on the >600-page technology assessment report, which aimed at evaluating ADHD treatment strategies by a clinical effectiveness review and an economic analysis using meta-analytical techniques and a cost-effectiveness model. Results The technology assessment was unable to differentiate between the various drugs in terms of efficacy, and its economic model was ultimately driven by cost differences. While the assessment concluded that the economic model "clearly identified an optimal treatment strategy" with first-line dexamphetamine, the NICE appraisal committee subsequently found it impossible to distinguish between the different strategies on grounds of cost-effectiveness. Analyzing the assessment reveals gaps and inconsistencies concerning data selection (ultimately relying on a small number of short-term studies only, data synthesis (pooling of heterogeneous study designs and clinical endpoints, and economic model structure (identifying double-counting of nonresponders as a likely source of bias, alongside further methodological anomalies. Conclusion Many conclusions of the NICE technology assessment rest on shaky grounds. There remains a need for a new, state-of-the-art systematic review of ADHD treatment strategies including economic evaluation, which ideally should address outcomes beyond children's health-related quality of life, such as long-term sequelae of the disorder and caregiver burden.

  19. Technology assessment of wind energy conversion systems

    Energy Technology Data Exchange (ETDEWEB)

    Meier, B. W.; Merson, T. J.

    1980-09-01

    Environmental data for wind energy conversion systems (WECSs) have been generated in support of the Technology Assessment of Solar Energy (TASE) program. Two candidates have been chosen to characterize the WECS that might be deployed if this technology makes a significant contribution to the national energy requirements. One WECS is a large machine of 1.5-MW-rated capacity that can be used by utilities. The other WECS is a small machine that is characteristic of units that might be used to meet residential or small business energy requirements. Energy storage systems are discussed for each machine to address the intermittent nature of wind power. Many types of WECSs are being studied and a brief review of the technology is included to give background for choosing horizontal axis designs for this study. Cost estimates have been made for both large and small systems as required for input to the Strategic Environmental Assessment Simulation (SEAS) computer program. Material requirements, based on current generation WECSs, are discussed and a general discussion of environmental impacts associated with WECS deployment is presented.

  20. Proceedings of The Twentieth International Symposium on Space Technology and Science. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-10-31

    The 20th international symposium on space technology and science was held in Nagaragawa city, Gifu prefecture on May 19-25, 1996, and 401 papers were made public. Out of those, 112 papers were summed up as Volume 2 following the previous Volume 1. As to space transportation, the paper included reports titled as follows: Conceptual study of H-IIA rocket (upgraded H-II rocket); Test flight of the launch vehicle; International cooperation in space transportation; etc. Concerning microgravity science, Recent advances in microgravity research; Use of microgravity environment to investigate the effect of magnetic field on flame shape; etc. Relating to satellite communications and broadcasting, `Project GENESYS`: CRL`s R and D project for realizing high data rate satellite communications networks; The Astrolink {sup TM/SM} system; etc. Besides, the paper contained reports on the following fields: lunar and planetary missions and utilization, space science and balloons, earth observations, life science and human presence, international cooperation and space environment, etc

  1. Horizontal oil well applications and oil recovery assessment. Volume 2: Applications overview, Final report

    Energy Technology Data Exchange (ETDEWEB)

    Deskins, W.G.; McDonald, W.J.; Knoll, R.G.; Springer, S.J.

    1995-03-01

    Horizontal technology has been applied in over 110 formations in the USA. Volume 1 of this study addresses the overall success of horizontal technology, especially in less-publicized formations, i.e., other than the Austin Chalk, Bakken, and Niobrara. Operators in the USA and Canada were surveyed on a formation-by-formation basis by means of a questionnaire. Response data were received describing horizontal well projects in 58 formations in the USA and 88 in Canada. Operators` responses were analyzed for trends in technical and economic success based on lithology (clastics and carbonates) and resource type (light oil, heavy oil, and gas). The potential impact of horizontal technology on reserves was also estimated. A forecast of horizontal drilling activity over the next decade was developed.

  2. Aerospace Technology Innovation. Volume 10

    Science.gov (United States)

    Turner, Janelle (Editor); Cousins, Liz (Editor); Bennett, Evonne (Editor); Vendette, Joel (Editor); West, Kenyon (Editor)

    2002-01-01

    Whether finding new applications for existing NASA technologies or developing unique marketing strategies to demonstrate them, NASA's offices are committed to identifying unique partnering opportunities. Through their efforts NASA leverages resources through joint research and development, and gains new insight into the core areas relevant to all NASA field centers. One of the most satisfying aspects of my job comes when I learn of a mission-driven technology that can be spun-off to touch the lives of everyday people. NASA's New Partnerships in Medical Diagnostic Imaging is one such initiative. Not only does it promise to provide greater dividends for the country's investment in aerospace research, but also to enhance the American quality of life. This issue of Innovation highlights the new NASA-sponsored initiative in medical imaging. Early in 2001, NASA announced the launch of the New Partnerships in Medical Diagnostic Imaging initiative to promote the partnership and commercialization of NASA technologies in the medical imaging industry. NASA and the medical imaging industry share a number of crosscutting technologies in areas such as high-performance detectors and image-processing tools. Many of the opportunities for joint development and technology transfer to the medical imaging market also hold the promise for future spin back to NASA.

  3. Comparison between visual assessment of MTA and hippocampal volumes in an elderly, non-demented population

    International Nuclear Information System (INIS)

    Cavallin, Lena; Axelsson, Rimma; Bronge, Lena; Zhang, Yi; Oeksengaard, Anne-Rita; Wahlund, Lars-Olof; Fratiglioni, Laura

    2012-01-01

    Background: It is important to have a replicable easy method for monitoring atrophy progression in Alzheimer's disease. Volumetric methods for calculating hippocampal volume are time-consuming and commonly used in research. Visual assessments of medial temporal lobe atrophy (vaMTA) is a rapid method for clinical use. This method has not been tested in a large non-demented population in comparison with volumetry measurements. Since hippocampal volume decreases with time even in normal aging there is also a need to study the normal age differences of medial temporal lobe atrophy. Purpose: To compare visual assessment of medial temporal lobe atrophy (vaMTA) with hippocampal volume in a healthy, non-demented elderly population. To describe normal ageing using vaMTA. Material and Methods: Non-demented individuals aged 60, 66, 72, 78, 81, 84, and ≥87 years old were recruited from the Swedish National study on Ageing and Care in Kungsholmen (SNAC-K), Sweden. Standard magnetic resonance imaging (MRI) scans, vaMTA, and calculations of hippocampal volumes were performed in 544 subjects. Results: Significant correlation (rs = -0.32, P 80-year-old individuals

  4. Unmanned Ground Vehicle Tactical Behaviors Technology Assessment

    National Research Council Canada - National Science Library

    Childers, Marshal A; Bodt, Barry A; Hill, Susan G; Camden, Richard; Dean, Robert M; Dodson, William F; Sutton, Lyle G; Sapronov, Leonid

    2009-01-01

    During 4-14 February 2008, the U.S. Army Research Laboratory and General Dynamics Robotic Systems conducted an unmanned systems tactical behaviors technology assessment at three training areas of Ft. Indiantown Gap, PA...

  5. Incorporating the Technology Roadmap Uncertainties into the Project Risk Assessment

    International Nuclear Information System (INIS)

    Bonnema, B.E.

    2002-01-01

    This paper describes two methods, Technology Roadmapping and Project Risk Assessment, which were used to identify and manage the technical risks relating to the treatment of sodium bearing waste at the Idaho National Engineering and Environmental Laboratory. The waste treatment technology under consideration was Direct Vitrification. The primary objective of the Technology Roadmap is to identify technical data uncertainties for the technologies involved and to prioritize the testing or development studies to fill the data gaps. Similarly, project management's objective for a multi-million dollar construction project includes managing all the key risks in accordance to DOE O 413.3 - ''Program and Project Management for the Acquisition of Capital Assets.'' In the early stages, the Project Risk Assessment is based upon a qualitative analysis for each risk's probability and consequence. In order to clearly prioritize the work to resolve the technical issues identified in the Technology Roadmap, the issues must be cross- referenced to the project's Risk Assessment. This will enable the project to get the best value for the cost to mitigate the risks

  6. Carbon Capture: A Technology Assessment

    Science.gov (United States)

    2013-10-21

    whereas laboratory-scale experiments typically seek to validate or obtain data for specific components of a system. Laboratory- and bench-scale processes...Plant,” Energy, vol. 35 (2010), pp. 841-850. E. Favre, R. Bounaceur, and D. Roizard, “ Biogas , Membranes and Carbon Dioxide Capture,” Journal of...pp. 1-49. 64 Favre, “ Biogas , Membranes.” Carbon Capture: A Technology Assessment Congressional Research Service 42 materials have pore sizes

  7. Progress report on nuclear science and technology in China (Vol.3). Proceedings of academic annual meeting of China Nuclear Society in 2013, No.9--nuclear technology applied in industry sub-volume

    International Nuclear Information System (INIS)

    2014-05-01

    Progress report on nuclear science and technology in China (Vol. 3) includes 35 articles which are communicated on the third national academic annual meeting of China Nuclear Society. There are 10 books totally. This is the ninth one, the content is about nuclear technology applied in industry sub-volume

  8. Strategic Planning Tools for Large-Scale Technology-Based Assessments

    Science.gov (United States)

    Koomen, Marten; Zoanetti, Nathan

    2018-01-01

    Education systems are increasingly being called upon to implement new technology-based assessment systems that generate efficiencies, better meet changing stakeholder expectations, or fulfil new assessment purposes. These assessment systems require coordinated organisational effort to implement and can be expensive in time, skill and other…

  9. RELAP5/MOD3 code manual: Summaries and reviews of independent code assessment reports. Volume 7, Revision 1

    International Nuclear Information System (INIS)

    Moore, R.L.; Sloan, S.M.; Schultz, R.R.; Wilson, G.E.

    1996-10-01

    Summaries of RELAP5/MOD3 code assessments, a listing of the assessment matrix, and a chronology of the various versions of the code are given. Results from these code assessments have been used to formulate a compilation of some of the strengths and weaknesses of the code. These results are documented in the report. Volume 7 was designed to be updated periodically and to include the results of the latest code assessments as they become available. Consequently, users of Volume 7 should ensure that they have the latest revision available

  10. Underground Test Area Subproject Phase I Data Analysis Task. Volume VIII - Risk Assessment Documentation Package

    Energy Technology Data Exchange (ETDEWEB)

    None

    1996-12-01

    Volume VIII of the documentation for the Phase I Data Analysis Task performed in support of the current Regional Flow Model, Transport Model, and Risk Assessment for the Nevada Test Site Underground Test Area Subproject contains the risk assessment documentation. Because of the size and complexity of the model area, a considerable quantity of data was collected and analyzed in support of the modeling efforts. The data analysis task was consequently broken into eight subtasks, and descriptions of each subtask's activities are contained in one of the eight volumes that comprise the Phase I Data Analysis Documentation.

  11. Multi-Criteria Sustainability Assessment of Urban Sludge Treatment Technologies

    DEFF Research Database (Denmark)

    An, Da; Xi, Beidou; Ren, Jingzheng

    2017-01-01

    to determine the weights of the criteria for sustainability assessment, and extension theory was used to prioritize the alternative technologies for the treatment of urban sewage sludge and grade their sustainability performances. An illustrative case including three technologies (compositing, incineration...

  12. Review of early assessment models of innovative medical technologies

    DEFF Research Database (Denmark)

    Fasterholdt, Iben; Krahn, Murray D; Kidholm, Kristian

    2017-01-01

    INTRODUCTION: Hospitals increasingly make decisions regarding the early development of and investment in technologies, but a formal evaluation model for assisting hospitals early on in assessing the potential of innovative medical technologies is lacking. This article provides an overview of models...

  13. [Assessment of an educational technology in the string literature about breastfeeding].

    Science.gov (United States)

    de Oliveira, Paula Marciana Pinheiro; Pagliuca, Lorita Marlena Freitag

    2013-02-01

    The goal of this study was to assess educational technology in the string literature about breastfeeding. The study was conducted between March and September 2009 by breastfeeding experts and experts on string literature. A psychometric model was adopted as the theoretical-methodological framework. For data collection, an instrument was used to assess the content about breastfeeding and the string literature rules. The analysis was based on comparisons of the notes and critical reflections of experts. Ethical guidelines were followed during the study. After the assessments, the educational technology was adjusted until all of the experts agreed. The assessment of educational technology can reduce obstacles to information dissemination and can lead to improvements in quality of life.

  14. Social and ethical analysis in health technology assessment.

    Science.gov (United States)

    Tantivess, Sripen

    2014-05-01

    This paper presents a review of the domestic and international literature on the assessment of the social and ethical implications of health technologies. It gives an overview of the key concepts, principles, and approaches that should be taken into account when conducting a social and ethical analysis within health technology assessment (HTA). Although there is growing consensus among healthcare experts that the social and ethical ramifications of a given technology should be examined before its adoption, the demand for this kind of analysis among policy-makers around the world, including in Thailand, has so far been lacking. Currently decision-makers mainly base technology adoption decisions using evidence on clinical effectiveness, value for money, and budget impact, while social and ethical aspects have been neglected. Despite the recognized importance of considering equity, justice, and social issues when making decisions regarding health resource allocation, the absence of internationally-accepted principles and methodologies, among other factors, hinders research in these areas. Given that developing internationally agreed standards takes time, it has been recommended that priority be given to defining processes that are justifiable, transparent, and contestable. A discussion of the current situation in Thailand concerning social and ethical analysis of health technologies is also presented.

  15. Suitability assessment of building energy saving technologies for office buildings in cold areas of China based on an assessment framework

    International Nuclear Information System (INIS)

    Geng, Geng; Wang, Zhaoxia; Zhao, Jing; Zhu, Neng

    2015-01-01

    Highlights: • An assessment method considering economy, environment and technology is proposed. • Office buildings are classified into 3 types and weights are calculated respectively. • BESTs were summed up as 3 suitability levels. • Recommendations are proposed for adopting in design stage. - Abstract: Blind application and extensive copy of building energy saving technologies have been found very common through investigation in China. Emphases should be put on the suitability assessment when selecting and optimizing building energy saving technologies. This paper created an assessment method, namely an assessment framework to assess the suitability level of building energy saving technologies from a holistic point of view. Fuzzy analytic hierarchy process was adopted. 3 factors and 8 sub-factors were included in the framework. The office buildings were classified into 3 types to calculate weights of factors and sub-factors. The assessment framework was established for each type of office buildings. 20 energy saving technologies from surveyed cases was selected as case study. Ranks of suitability level of the assessment objects were obtained for each type of office buildings. The assessment results could be referred when selecting building energy saving technologies in the design stage

  16. DYNAPHORE, INC., FORAGER SPONGE TECHNOLOGY - INNOVATIVE TECHNOLOGY EVALUATION REPORT

    Science.gov (United States)

    The Forager Sponge is a volume reduction technology in which heavy metal contaminants from an aqueous medium are selectively concentrated into a smaller volume for facilitated disposal. he technology treats contaminated groundwater, surface voters and porous waters by absorbing d...

  17. Proceedings of the Twenty-First Water Reactor Safety Information Meeting: Volume 1, Plenary session; Advanced reactor research; advanced control system technology; advanced instrumentation and control hardware; human factors research; probabilistic risk assessment topics; thermal hydraulics; thermal hydraulic research for advanced passive LWRs

    International Nuclear Information System (INIS)

    Monteleone, S.

    1994-04-01

    This three-volume report contains 90 papers out of the 102 that were presented at the Twenty-First Water Reactor Safety Information Meeting held at the Bethesda Marriott Hotel, Bethesda, Maryland, during the week of October 25--27, 1993. The papers are printed in the order of their presentation in each session and describe progress and results of programs in nuclear safety research conducted in this country and abroad. Foreign participation in the meeting included papers presented by researchers from France, Germany, Japan, Russia, Switzerland, Taiwan, and United Kingdom. The titles of the papers and the names of the authors have been updated and may differ from those that appeared in the final program of the meeting. Individual papers have been cataloged separately. This document, Volume 1 covers the following topics: Advanced Reactor Research; Advanced Instrumentation and Control Hardware; Advanced Control System Technology; Human Factors Research; Probabilistic Risk Assessment Topics; Thermal Hydraulics; and Thermal Hydraulic Research for Advanced Passive Light Water Reactors

  18. Proceedings of the Twenty-First Water Reactor Safety Information Meeting: Volume 1, Plenary session; Advanced reactor research; advanced control system technology; advanced instrumentation and control hardware; human factors research; probabilistic risk assessment topics; thermal hydraulics; thermal hydraulic research for advanced passive LWRs

    Energy Technology Data Exchange (ETDEWEB)

    Monteleone, S. [Brookhaven National Lab., Upton, NY (United States)] [comp.

    1994-04-01

    This three-volume report contains 90 papers out of the 102 that were presented at the Twenty-First Water Reactor Safety Information Meeting held at the Bethesda Marriott Hotel, Bethesda, Maryland, during the week of October 25--27, 1993. The papers are printed in the order of their presentation in each session and describe progress and results of programs in nuclear safety research conducted in this country and abroad. Foreign participation in the meeting included papers presented by researchers from France, Germany, Japan, Russia, Switzerland, Taiwan, and United Kingdom. The titles of the papers and the names of the authors have been updated and may differ from those that appeared in the final program of the meeting. Individual papers have been cataloged separately. This document, Volume 1 covers the following topics: Advanced Reactor Research; Advanced Instrumentation and Control Hardware; Advanced Control System Technology; Human Factors Research; Probabilistic Risk Assessment Topics; Thermal Hydraulics; and Thermal Hydraulic Research for Advanced Passive Light Water Reactors.

  19. Radionuclide stroke count ratios for assessment of right and left ventricular volume overload in children

    International Nuclear Information System (INIS)

    Parrish, M.D.; Graham, T.P. Jr.; Born, M.L.; Jones, J.P.; Boucek, R.J. Jr.; Artman, M.; Partain, C.L.

    1983-01-01

    The ratio of left ventricular to right ventricular stroke counts measured by radionuclide angiography has been used in adults to estimate the severity of left-sided valvular regurgitation. The validation of this technique in children for assessment of right and left ventricular volume overload is reported herein. Radionuclide stroke count ratios in 60 children aged 0.5 to 19 years (mean 11) were determined. Based on their diagnoses, the patients were divided into 3 groups: (1) normal--40 patients with no shunts or valvular regurgitation, (2) left ventricular volume overload--13 patients with mitral or aortic regurgitation, or both, and (3) right ventricular volume overload--7 patients, 2 with severe tricuspid regurgitation, 3 with atrial septal defects, and 2 with total anomalous pulmonary venous drainage. The radionuclide stroke count ratio clearly differentiated these groups (p less than 0.05): normal patients had a stroke count ratio of 1.04 +/- 0.17 (mean +/- 1 standard deviation), the left ventricular volume overload group had a stroke count ratio of 2.43 +/- 0.86, and the right ventricular volume overload group had a stroke count ratio of 0.44 +/- 0.17. In 22 of our 60 patients, radionuclide stroke count ratios were compared with cineangiographic stroke volume ratios, resulting in a correlation coefficient of 0.88. It is concluded that radionuclide ventriculography is an excellent tool for qualitative and quantitative assessment of valvular regurgitation in children

  20. Critical Metals in Strategic Energy Technologies. Assessing Rare Metals as Supply-Chain Bottlenecks in Low-Carbon Energy Technologies

    International Nuclear Information System (INIS)

    Moss, R.L.; Tzimas, E.; Kara, H.; Willis, P.; Kooroshy, J.

    2011-11-01

    Due to the rapid growth in demand for certain materials, compounded by political risks associated with the geographical concentration of the supply of them, a shortage of these materials could be a potential bottleneck to the deployment of low-carbon energy technologies. In order to assess whether such shortages could jeopardise the objectives of the EU's Strategic Energy Technology Plan (SET-Plan), an improved understanding of these risks is vital. In particular, this report examines the use of metals in the six low-carbon energy technologies of SET-Plan, namely: nuclear, solar, wind, bioenergy, carbon capture and storage (CCS) and electricity grids. The study looks at the average annual demand for each metal for the deployment of the technologies in Europe between 2020 and 2030. The demand of each metal is compared to the respective global production volume in 2010. This ratio (expressed as a percentage) allows comparing the relative stress that the deployment of the six technologies in Europe is expected to create on the global supplies for these different metals. The study identifies 14 metals for which the deployment of the six technologies will require 1% or more (and in some cases, much more) of current world supply per annum between 2020 and 2030. These 14 metals, in order of decreasing demand, are tellurium, indium, tin, hafnium, silver, dysprosium, gallium, neodymium, cadmium, nickel, molybdenum, vanadium, niobium and selenium. The metals are examined further in terms of the risks of meeting the anticipated demand by analysing in detail the likelihood of rapid future global demand growth, limitations to expanding supply in the short to medium term, and the concentration of supply and political risks associated with key suppliers. The report pinpoints 5 of the 14 metals to be at high risk, namely: the rare earth metals neodymium and dysprosium, and the by-products (from the processing of other metals) indium, tellurium and gallium. The report explores a

  1. Preliminary environmental assessment for the Satellite Power System (SPS). Revision 1. Volume 2. Detailed assessment

    Energy Technology Data Exchange (ETDEWEB)

    1980-01-01

    The Department of Energy (DOE) is considering several options for generating electrical power to meet future energy needs. The satellite power system (SPS), one of these options, would collect solar energy through a system of satellites in space and transfer this energy to earth. A reference system has been described that would convert the energy to microwaves and transmit the microwave energy via directive antennas to large receiving/rectifying antennas (rectennas) located on the earth. At the rectennas, the microwave energy would be converted into electricity. The potential environmental impacts of constructing and operating the satellite power system are being assessed as a part of the Department of Energy's SPS Concept Development and Evaluation Program. This report is Revision I of the Preliminary Environmental Assessment for the Satellite Power System published in October 1978. It refines and extends the 1978 assessment and provides a basis for a 1980 revision that will guide and support DOE recommendations regarding future SPS development. This is Volume 2 of two volumes. It contains the technical detail suitable for peer review and integrates information appearing in documents referenced herein. The key environmental issues associated with the SPS concern human health and safety, ecosystems, climate, and electromagnetic systems interactions. In order to address these issues in an organized manner, five tasks are reported: (I) microwave-radiation health and ecological effects; (II) nonmicrowave health and ecological effectss; (III) atmospheric effects; (IV) effects on communication systems due to ionospheric disturbance; and (V) electromagnetic compatibility. (WHK)

  2. Scenario drafting to anticipate future developments in technology assessment

    NARCIS (Netherlands)

    Retel, Valesca; Retel, V.P.; Joore, M.A.; Rutgers, E.J.; van Harten, Willem H.

    2012-01-01

    Background Health Technology Assessment (HTA) information, and in particular cost-effectiveness data is needed to guide decisions, preferably already in early stages of technological development. However, at that moment there is usually a high degree of uncertainty, because evidence is limited and

  3. Health technology assessment in Australia: The role of AHTAC

    International Nuclear Information System (INIS)

    Kearney, B.; Willis, E.

    1997-01-01

    This paper outlines and discusses the field of medical technology assessment and the role of the Australian Health Technology Advisory Committee (AHTAC) in that process. Developments in medical technologies have altered the way in which health care is practised and delivered. As part of its work program, AHTAC has re-evaluating some existing medical technologies to assess how and under what circumstances new developments can contribute to the alleviation of the illness and suffering of the patients. Three case studies are described. These are: magnetic resonance imaging, diagnostic ultrasound and beam and isotope radiotherapy. It is stressed that the policy task is a complex one attempting to balance the need for cost containment whilst at the same time ensuring that the processes of innovation into Australia and diffusion occur in a manner which maximizes the benefit and minimizes any harm to the Australian community

  4. A 3-D method for delineation of activity distributions and assessment of functional organ volumes with SPECT

    International Nuclear Information System (INIS)

    Wang, Y.; Karolinska Hospital and Karolinska Inst., Stockholm; Jacobsson, H.; Jacobson, S.H.; Kimiaei, S.; Larsson, S.A.

    1995-01-01

    The distrubution volume of an organ may have a clinical impact in many cases and various methods have been designed to make volume assessments. In this paper, we describe a new method for delineation of the distribution outline and volume determination. The method is based on smoothing, differentiation, image relaxation and voxel counting of single photon emission computer tomography (SPECT) image sets with 3-D operators. A special routine corrects for the inherent thickness of the voxel-based outline. Phantom experiments, using a SPECT system with LEGP-collimator and a 64x64 acquisition matrix with 6.3x6.3 mm 2 pixel size, demonstrated good correlation between the measured and the true volumes. For volumes larger than 120 cc the correlation coefficient was 0.9999 with SE 1.0 cc and an average relative deviation of 0.49%. For volumes below 120 cc, the accuracy was impaired due to low resolution power. By improving the system spatial resolution with an LEHR-collimator and a smaller pixel-size (4.1x4.1 mm 2 ), good accuracy was achieved also for volumes in the range from 3 to 120 cc. Measurements of 15 differently shaped phantoms of volumes between 3 and 104 cc demonstrated high correlation between measured and true volumes: R=0.9921 and SE=0.74 cc (5.3%). For volumes as small as 3 and 5 cc, the difference between the true and the assessed volume was 0.6 cc. The reproducibility of the method was within 3% for volumes above 120 cc and within 7% for volumes below. Due to this accuracy, we conclude that the method can be applied for various clinical routine and research applications using SPECT. (orig.)

  5. Decision Gate Process for Assessment of a Technology Development Portfolio

    Science.gov (United States)

    Kohli, Rajiv; Fishman, Julianna; Hyatt, Mark

    2012-01-01

    The NASA Dust Management Project (DMP) was established to provide technologies (to TRL 6 development level) required to address adverse effects of lunar dust to humans and to exploration systems and equipment, which will reduce life cycle cost and risk, and will increase the probability of sustainable and successful lunar missions. The technology portfolio of DMP consisted of different categories of technologies whose final product is either a technology solution in itself, or one that contributes toward a dust mitigation strategy for a particular application. A Decision Gate Process (DGP) was developed to assess and validate the achievement and priority of the dust mitigation technologies as the technologies progress through the development cycle. The DGP was part of continuous technology assessment and was a critical element of DMP risk management. At the core of the process were technology-specific criteria developed to measure the success of each DMP technology in attaining the technology readiness levels assigned to each decision gate. The DGP accounts for both categories of technologies and qualifies the technology progression from technology development tasks to application areas. The process provided opportunities to validate performance, as well as to identify non-performance in time to adjust resources and direction. This paper describes the overall philosophy of the DGP and the methodology for implementation for DMP, and describes the method for defining the technology evaluation criteria. The process is illustrated by example of an application to a specific DMP technology.

  6. Joint Peru/United States report on Peru/United States cooperative energy assessment. Volume 4 of 4 Volumes Annexes 8-11

    Energy Technology Data Exchange (ETDEWEB)

    1979-08-01

    A comprehensive assessment of the biofuel potential of Peru is presented. Topics discussed cover current biofuel utilization practices; evaluation of Peruvian biomass productivity; identification of Peruvian agricultural and forestry resources; assessment of resource development and management concerns; identification of market considerations; description of biofuel technological options; and regional identification of biofuel technology applications. The discussion of current biofuel utilization centers on a qualitative description of the main conversion approaches now being practiced in Peru. Biomass productivity is evaluated in the context of the terrain, soil, and climatic conditions found in Peru. A quantitative description of the energy potential that could be realized from agricultural and forestry resources of Peru follows. A regional picture is given for the production of agricultural residues and forest resources that could potentially supply energy. The assessment of resource development and management concerns focuses on harvesting, reforestation, training, and the environmental consequences of utilization of forest resources. Market factors assessed include: importation, internal market development, external market development, energy policy and pricing, and transportation. Ten biofuel technology options for Peru were identified: small- to medium-scale gasification, a wood waste inventory, stationary and mobile charcoal production systems, wood distillation, forest resource development and management, electrical cogeneration, anaerobic digestion technology, development of ethanol production capabilities, and agricultural strategies for fuel production.Based upon these biofuel options, nine applications were identified for the Costa Region, eight for the Sierra Region, and ten for the Selva Region.

  7. Technology needs assessment (TNA) resource document for South Africa

    CSIR Research Space (South Africa)

    Taviv, R

    2007-08-01

    Full Text Available TNA(Technology needs assessment) is a requirement of Article 4.5 of the UNFCCC ‘Technology Transfer’ is a broad set of processes covering the flows of know-how, experience and equipment for mitigating or adapting to climate change amongst different...

  8. Tiger Team Assessment, Energy Technology Engineering Center

    International Nuclear Information System (INIS)

    1991-04-01

    The Office Special Projects within the Office of Environment, Safety, and Health (EH) has the responsibility to conduct Tiger Team Assessments for the Secretary of Energy. This report presents the assessment of the buildings, facilities, and activities under the DOE/Rockwell Contract No. DE-AM03-76SF00700 for the Energy Technology Engineering Center (ETEC) and of other DOE-owned buildings and facilities at the Santa Susana Field Laboratory (SSFL) site in southeastern Ventura County, California, not covered under Contract No. DE-AM03-76SF00700, but constructed over the years under various other contracts between DOE and Rockwell International. ETEC is an engineering development complex operated for DOE by the Rocketdyne Division of Rockwell International Corporation. ETEC is located within SSFL on land owned by Rockwell. The balance of the SSFL complex is owned and operated by Rocketdyne, with the exception of a 42-acre parcel owned by the National Aeronautics and Space Administration (NASA). The primary mission of ETEC is to provide engineering, testing, and development of components related to liquid metals technology and to conduct applied engineering development of emerging energy technologies

  9. Tiger Team Assessment, Energy Technology Engineering Center

    Energy Technology Data Exchange (ETDEWEB)

    1991-04-01

    The Office Special Projects within the Office of Environment, Safety, and Health (EH) has the responsibility to conduct Tiger Team Assessments for the Secretary of Energy. This report presents the assessment of the buildings, facilities, and activities under the DOE/Rockwell Contract No. DE-AM03-76SF00700 for the Energy Technology Engineering Center (ETEC) and of other DOE-owned buildings and facilities at the Santa Susana Field Laboratory (SSFL) site in southeastern Ventura County, California, not covered under Contract No. DE-AM03-76SF00700, but constructed over the years under various other contracts between DOE and Rockwell International. ETEC is an engineering development complex operated for DOE by the Rocketdyne Division of Rockwell International Corporation. ETEC is located within SSFL on land owned by Rockwell. The balance of the SSFL complex is owned and operated by Rocketdyne, with the exception of a 42-acre parcel owned by the National Aeronautics and Space Administration (NASA). The primary mission of ETEC is to provide engineering, testing, and development of components related to liquid metals technology and to conduct applied engineering development of emerging energy technologies.

  10. Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR): Volume 1, Summary description

    International Nuclear Information System (INIS)

    Gertman, D.I.; Gilmore, W.E.; Galyean, W.J.; Groh, M.R.; Gentillon, C.D.; Gilbert, B.G.

    1988-02-01

    A data management system has been implemented which supports a variety of risk-related analyses and provides a repository of hardware component failure and human error probability data to the risk analyst. The Nuclear Computerized Library for Assessing Reactor Reliability, NUCLARR, is an interactive, graphically oriented system which resides on a personal computer (PC) or PC-compatible environment. An overview of the data management system, including a description of data collection, specification, data structure, and taxonomies, is presented in Volume I of this report. Programming activities, procedures for processing data, user's guide, and hard copy data manual are presented in Volumes II through V

  11. Robins Air Force Base integrated resource assessment. Volume 3, Resource assessment

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, G.P.; Keller, J.M.; Stucky, D.J.; Wahlstrom, R.R.; Larson, L.L.

    1993-10-01

    The US Air Force Materiel Command (AFMC) has tasked the US Department of Energy (DOE) Federal Energy Management Program (FEMP), supported by the Pacific Northwest Laboratory (PNL), to identify, evaluate, and assist in acquiring all cost-effective energy projects at Robins Air Force Base (AFB). This is part of a model program that PNL is designing to support energy-use decisions in the federal sector. This report provides the results of the fossil fuel and electric energy resource opportunity (ERO) assessments performed by PNL at the AFMC Robins AFB facility located approximately 15 miles south of Macon, Georgia. It is a companion report to Volume 1, Executive Summary, and Volume 2, Baseline Detail. The results of the analyses of EROs are presented in 13 common energy end-use categories (e.g., boilers and furnaces, service hot water, and building lighting). A narrative-description of each ERO is provided, including information on the installed cost, energy and dollar savings; impacts on operation and maintenance (O&M); and, when applicable, a discussion of energy supply and demand, energy security, and environmental issues. A description of the evaluation methodologies and technical and cost assumptions is also provided for each ERO. Summary tables present the cost-effectiveness of energy end-use equipment before and after the implementation of each ERO and present the results of the life-cycle cost (LCC) analysis indicating the net present value (NPV) and savings to investment ratio (SIR) of each ERO.

  12. Technology enhanced peer learning and peer assessment

    DEFF Research Database (Denmark)

    Henriksen, Christian Bugge; Bregnhøj, Henrik; Rosthøj, Susanne

    2016-01-01

    This paper explores the application of learning designs featuring formalised and structured technology enhanced peer learning. These include student produced learning elements, peer review discussions and peer assessment in the BSc/MSc level summer course Restoration of European Ecosystems and Fr...... be a huge benefit from developing learning design patterns that facilitate informal peer learning and reinforce knowledge sharing practices.......This paper explores the application of learning designs featuring formalised and structured technology enhanced peer learning. These include student produced learning elements, peer review discussions and peer assessment in the BSc/MSc level summer course Restoration of European Ecosystems...... and Freshwaters (REEF), the Master thesis preparation seminars for the Master of Public Health (MPH) and the MOOC course Global Environmental Management (GEM). The application of student produced learning elements and peer review discussions is investigated by analyzing quotes from course evaluations...

  13. Technologies for Interactive Learning and Assessment Content Development

    Science.gov (United States)

    Gusev, Marjan; Ristov, Sasko; Armenski, Goce

    2016-01-01

    Recent technology trends evolved the student assessment from traditional ones ("pen-and-paper" and "face-to-face") to modern e-Assessment system. These modern approaches allow the teachers to conduct and evaluate an exam with huge number of students in a short period of time. Even more important, both the teacher and the…

  14. Vocal Sight-Reading Assessment: Technological Advances, Student Perceptions, and Instructional Implications

    Science.gov (United States)

    Henry, Michele

    2015-01-01

    This study investigated choral singers' comfort level using computer technology for vocal sight-reading assessment. High school choral singers (N = 138) attending a summer music camp completed a computer-based sight-reading assessment and accompanying pre- and posttest surveys on their musical backgrounds and perceptions about technology. A large…

  15. Immobilization of defense high-level waste: an assessment of technological strategies and potential regulatory goals. Volume II

    International Nuclear Information System (INIS)

    1979-06-01

    This volume contains the following appendices: selected immobilization processes, directory of selected European organizations involved in HLW management, U.S. high-level waste inventories, and selected European HLW program

  16. Independent Orbiter Assessment (IOA): Assessment of the main propulsion subsystem FMEA/CIL, volume 2

    Science.gov (United States)

    Holden, K. A.

    1988-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Main Propulsion System (MPS) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were than compared to available data from the Rockwell Downey/NASA JSC FMEA/CIL review. Volume 2 continues the presentation of IOA worksheets for MPS hardware items.

  17. Advancing automation and robotics technology for the Space Station and for the US economy. Volume 1: Executive overview

    Science.gov (United States)

    1985-01-01

    In response to Public Law 98-371, dated July 18, 1984, the NASA Advanced Technology Advisory Committee has studied automation and robotics for use in the Space Station. The Executive Overview, Volume 1 presents the major findings of the study and recommends to NASA principles for advancing automation and robotics technologies for the benefit of the Space Station and of the U.S. economy in general. As a result of its study, the Advanced Technology Advisory Committee believes that a key element of technology for the Space Station is extensive use of advanced general-purpose automation and robotics. These systems could provide the United States with important new methods of generating and exploiting space knowledge in commercial enterprises and thereby help preserve U.S. leadership in space.

  18. The role of surgeons in identifying emerging technologies for health technology assessment.

    Science.gov (United States)

    Stafinski, Tania; Topfer, Leigh-Ann; Zakariasen, Ken; Menon, Devidas

    2010-04-01

    Health technology assessment (HTA) is a tool intended to help policy-makers decide which technologies to fund. However, given the proliferation of new technologies, it is not possible to undertake an HTA of each one before it becomes funded. Consequently, "horizon-scanning" processes have been developed to identify emerging technologies that are likely to have a substantial impact on clinical practice. Although the importance of physicians in the adoption of new technologies is well recognized, their role in horizon scanning in Canada has been limited. The purpose of this project was to pilot an approach to engage physicians, specifically surgeons, in provincial horizon-scanning activities. We invited 18 surgeons from Alberta's 2 medical schools to a horizon-scanning workshop to solicit their views on emerging technologies expected to impact surgical practice within the next 5 years and/or the importance of different attributes or characteristics of new technologies. Surgeons, regardless of specialty, identified developments designed to enhance existing minimally invasive surgical techniques, such as endoscopic, robotic and image-guided surgery. Several nonsurgical areas, including molecular genetics and nano technology, were also identified. Of the 13 technology attributes discussed, safety or risk, effectiveness and feasibility were rated as most important. Lastly, participating surgeons expressed an interest in becoming further involved in local HTA initiatives. Surgeons, as adopters and users of health technologies, represent an important and accessible information source for identifying emerging technologies for HTA. A more formal, ongoing relationship between the government, HTA and surgeons may help to optimize the use of HTA resources.

  19. Wearable technology for spine movement assessment: A systematic review

    OpenAIRE

    Papi, Enrica; Koh, Woon Senn; McGregor, Alison H.

    2017-01-01

    Continuous monitoring of spine movement function could enhance our understanding of low back pain development. Wearable technologies have gained popularity as promising alternative to laboratory systems in allowing ambulatory movement analysis. This paper aims to review the state of art of current use of wearable technology to assess spine kinematics and kinetics. Four electronic databases and reference lists of relevant articles were searched to find studies employing wearable technologies t...

  20. Assessment of Wearable Sensor Technologies for Biosurveillance

    Science.gov (United States)

    2014-11-01

    include: textile-based wearable sensors, epidermal tattoos, DNA and protein sensors, forensic detection of explosives, remote environmental sensing...Assessment of Wearable Sensor Technologies for Biosurveillance P a g e 4 3 David L. Hirschberg, PhD Assistant Professor, Clinical Pathology

  1. Technology enhanced peer learning and peer assessment

    DEFF Research Database (Denmark)

    Henriksen, Christian Bugge; Bregnhøj, Henrik; Rosthøj, Susanne

    2016-01-01

    This paper explores the application of learning designs featuring formalised and structured technology enhanced peer learning. These include student produced learning elements, peer review discussions and peer assessment in the BSc/MSc level summer course Restoration of European Ecosystems...... and Freshwaters (REEF), the Master thesis preparation seminars for the Master of Public Health (MPH) and the MOOC course Global Environmental Management (GEM). The application of student produced learning elements and peer review discussions is investigated by analyzing quotes from course evaluations...... and performing focus group interviews. The application of peer assessment is investigated by analyzing the agreement of peer assessment between students assessing the same assignment. Our analyses confirm previous research on the value of peer learning and peer assessment and we argue that there could also...

  2. Progress report on nuclear science and technology in China (Vol.3). Proceedings of academic annual meeting of China Nuclear Society in 2013, No.7--pulse power technology and its application sub-volume

    International Nuclear Information System (INIS)

    2014-05-01

    Progress report on nuclear science and technology in China (Vol. 3) includes 18 articles which are communicated on the third national academic annual meeting of China Nuclear Society. There are 10 books totally. This is the seventh one, the content is about pulse power technology and its application sub-volume

  3. Progress report on nuclear science and technology in China (Vol.3). Proceedings of academic annual meeting of China Nuclear Society in 2013, No.7--Nuclear electronics and nuclear detection technology sub-volume

    International Nuclear Information System (INIS)

    2014-05-01

    Progress report on nuclear science and technology in China (Vol. 3) includes 57 articles which are communicated on the third national academic annual meeting of China Nuclear Society. There are 10 books totally. This is the seventh one, the content is about Nuclear electronics and nuclear detection technology sub-volume

  4. Progress report on nuclear science and technology in China (Vol.3). Proceedings of academic annual meeting of China Nuclear Society in 2013, No.10--nuclear technology economy and management modernization sub-volume

    International Nuclear Information System (INIS)

    2014-05-01

    Progress report on nuclear science and technology in China (Vol. 3) includes 18 articles which are communicated on the third national academic annual meeting of China Nuclear Society. There are 10 books totally. This is the tenth one, the content is about nuclear technology economy and management modernization sub-volume

  5. Assessment at UK medical schools varies substantially in volume, type and intensity and correlates with postgraduate attainment.

    Science.gov (United States)

    Devine, Oliver Patrick; Harborne, Andrew Christopher; McManus, I C

    2015-09-11

    In the United Kingdom (UK), medical schools are free to develop local systems and policies that govern student assessment and progression. Successful completion of an undergraduate medical degree results in the automatic award of a provisional licence to practice medicine by the General Medical Council (GMC). Such a licensing process relies heavily on the assumption that individual schools develop similarly rigorous assessment policies. Little work has evaluated variability of undergraduate medical assessment between medical schools. That absence is important in the light of the GMC's recent announcement of the introduction of the UKMLA (UK Medical Licensing Assessment) for all doctors who wish to practise in the UK. The present study aimed to quantify and compare the volume, type and intensity of summative assessment across medicine (A100) courses in the United Kingdom, and to assess whether intensity of assessment correlates with the postgraduate attainment of doctors from these schools. Locally knowledgeable students in each school were approached to take part in guided-questionnaire interviews via telephone or Skype(TM). Their understanding of assessment at their medical school was probed, and later validated with the assessment department of the respective medical school. We gathered data for 25 of 27 A100 programmes in the UK and compared volume, type and intensity of assessment between schools. We then correlated these data with the mean first-attempt score of graduates sitting MRCGP and MRCP(UK), as well as with UKFPO selection measures. The median written assessment volume across all schools was 2000 min (mean = 2027, SD = 586, LQ = 1500, UQ = 2500, range = 1000-3200) and 1400 marks (mean = 1555, SD = 463, LQ = 1200, UQ = 1800, range = 1100-2800). The median practical assessment volume was 400 min (mean = 472, SD = 207, LQ = 400, UQ = 600, range = 200-1000). The median intensity (minutes per mark ratio) of summative written assessment was 1.24 min per mark

  6. Techno-experiential design assessment and media experience database: A method for emerging technology assessment

    OpenAIRE

    Schick, Dan

    2005-01-01

    This thesis evaluates the Techno-Experiential Design Assessment (TEDA) for social research on new media and emerging technology. Dr. Roman Onufrijchuk developed TEDA to address the shortcomings of current methods designed for studying existing technologies. Drawing from the ideas of Canadian media theorist Marshall McLuhan, TEDA focuses on the environmental changes introduced by a new technology into a user's life. I describe the key components of the TEDA methodology and provide examples of ...

  7. Assessment of bone mineral content in the internal bone volume

    International Nuclear Information System (INIS)

    Hoeiseth, A.; Alho, A.; Husby, T.; Ullevaal Sykehus, Oslo

    1991-01-01

    A method for assessing values related to bone density and mass is described. Mean attenuation and pixel area are measured in pixels selected on the basis of CT units. The method is to a large extent computerized and not dependent on manual positioning or outlining of a region of interest. Because it is not dependent on a comparatively large volume of homogeneous bone it can be used to make assessments even in very heterogeneous bones including cortical bone. The method is adaptable for measurement in all parts of the skeleton and values related to both bone density (DRV) and bone mass (MRV) are derived. The measurements in the femoral condyles were shown to have a precision of approximately 0.25 to 0.30 Z-score units (standard deviation of the measurements expressed in Z-score units). The agreement between chemically analyzed calcium density (weight of calcium per volume) and DRV was little less than 0.50 Z-scores and 0.30 Z-scores for the chemically determined calcium mass and the MRV. The agreement with mechanical bone strength was 0.78 Z-scores for DRV and 0.64 for the MRV. Altering scan parameters or measuring approaches gave systematic differences in the measurements. There were, however, good linear correlations between the measurements which show that these different measuring approaches essentially gave identical measurements. (orig.)

  8. Technological pedagogical content knowledge of prospective mathematics teachers regarding evaluation and assessment

    Directory of Open Access Journals (Sweden)

    Ercan Atasoy

    2016-04-01

    Full Text Available The ‘technology integrated assessment process’ is an innovative method to capture and determine students’ understanding of mathematics. This assessment process is claimed to provide a singular dynamism for teaching and learning activities and it is also claimed to be of the most important elements of instruction in the educational system. In this sense, this study aims to investigate technological pedagogical content knowledge (TPACK of prospective mathematics teachers regarding the ‘evaluation’ and ‘assessment’ process. To achieve this aim, the method of qualitative research was conducted with 20 teachers. Video records and lesson plans were collected and a Mathematics Teacher TPACK Development Model was utilized to reveal themes and key features of the data. The findings revealed that, although the majority of teachers stated that they would like to use technology-integrated tools in the assessment and evaluation processes, they strongly preferred to use traditional assessment and evaluation techniques, such as pen and paper activities, multiple-choice questions in virtual environments, etc. Hence, the evidence suggests that teachers would be unable to use appropriately the technological assessment process in order to reveal students’ understanding of mathematics. As seen from the teachers’ lectures, they perceived that technology would be suitable for evaluation and assessment but in a limited way.

  9. Sustainability assessment of renewable power and heat generation technologies

    International Nuclear Information System (INIS)

    Dombi, Mihály; Kuti, István; Balogh, Péter

    2014-01-01

    Rationalisation of consumption, more efficient energy usage and a new energy structure are needed to be achieved in order to shift the structure of energy system towards sustainability. The required energy system is among others characterised by intensive utilisation of renewable energy sources (RES). RES technologies have their own advantages and disadvantages. Nevertheless, for the strategic planning there is a great demand for the comparison of RES technologies. Furthermore, there are additional functions of RES utilisation expected beyond climate change mitigation, e.g. increment of employment, economic growth and rural development. The aim of the study was to reveal the most beneficial RES technologies with special respect to sustainability. Ten technologies of power generation and seven technologies of heat supply were examined in a multi-criteria sustainability assessment frame of seven attributes which were evaluated based on a choice experiment (CE) survey. According to experts the most important characteristics of RES utilisation technologies are land demand and social impacts i.e. increase in employment and local income generation. Concentrated solar power (CSP), hydropower and geothermal power plants are favourable technologies for power generation, while geothermal district heating, pellet-based non-grid heating and solar thermal heating can offer significant advantages in case of heat supply. - highlights: • We used choice experiment to estimate the weights of criteria for the sustainability assessment of RES technologies. • The most important attributes of RES technologies according to experts are land demand and social impacts. • Concentrated solar power (CSP), hydropower and geothermal power plants are advantageous technologies for power generation. • Geothermal district heating, pellet-based non-grid heating and solar thermal heating are favourable in case of heat supply

  10. Making Use of the New Student Assessment Standards To Enhance Technological Literacy.

    Science.gov (United States)

    Russell, Jill

    2003-01-01

    Describes the student assessment standards outlined in "Advancing Excellence in Technological Literacy: Student Assessment, Professional Development, and Program Standards," a companion to the "Standards for Technological Literacy." Discusses how the standards apply to everyday teaching practices. (JOW)

  11. Process for Selecting System Level Assessments for Human System Technologies

    Science.gov (United States)

    Watts, James; Park, John

    2006-01-01

    The integration of many life support systems necessary to construct a stable habitat is difficult. The correct identification of the appropriate technologies and corresponding interfaces is an exhaustive process. Once technologies are selected secondary issues such as mechanical and electrical interfaces must be addressed. The required analytical and testing work must be approached in a piecewise fashion to achieve timely results. A repeatable process has been developed to identify and prioritize system level assessments and testing needs. This Assessment Selection Process has been defined to assess cross cutting integration issues on topics at the system or component levels. Assessments are used to identify risks, encourage future actions to mitigate risks, or spur further studies.

  12. REPORT TO CONGRESS: ASSESSMENT OF INTERNATIONAL AIR POLLUTION PREVENTION AND CONTROL TECHNOLOGY VOLUME 1. EXECUTIVE SUMMARY

    Science.gov (United States)

    The report gives results of a study that identifies new and innovative air pollution prevention and/or control technologies, of selected industrialized countries, that are not currently used extensively in the U.S. The technologies may be entirely new to the U.S., or they may be ...

  13. Assessment of impacts from different waste treatment and waste disposal technologies: Regional Management Plan

    International Nuclear Information System (INIS)

    Robertson, B.C.; Sutherland, A.A.

    1986-01-01

    This report presents assessments of treatment and disposal technologies that appear to be appropriate for use in regional facilities in the Midwest Compact Region. The treatment technologies assessed: compaction with a supercompactor; incineration; and incineration followed by solidfication of the incinerator ash. The disposal technologies assessed are: shallow land burial, considered a baseline for comparison of other technologies; below-ground vaults; abov-groudn vaults; the earth mounded concrete bunker, a technology developed in France; improved shallow land burial, essentially deeper burial; modular concrete canister disposal; mined cavities (both new and existing); and unlined augered holes; and lined augered holes. The teatment technologies are assessed primarily in terms of the their impact on the waste management system, and generally not comparatively. The dispoal technologies are assessed relative to the present standard practice shallow land burial; shallow land burial was slected as a frame of reference because it has an experience base spanning several decades, not because of any preferential characteristics. 20 refs., 5 tabs

  14. ASSESSING INDIVIDUAL PERFORMANCE ON INFORMATION TECHNOLOGY ADOPTION: A NEW MODEL

    OpenAIRE

    Diah Hari Suryaningrum

    2012-01-01

    This paper aims to propose a new model in assessing individual performance on information technology adoption. The new model to assess individual performance was derived from two different theories: decomposed theory of planned behavior and task-technology fit theory. Although many researchers have tried to expand these theories, some of their efforts might lack of theoretical assumptions. To overcome this problem and enhance the coherence of the integration, I used a theory from social scien...

  15. Definition of technology development missions for early space station satellite servicing, volume 2

    Science.gov (United States)

    1983-01-01

    The results of all aspects of the early space station satellite servicing study tasks are presented. These results include identification of servicing tasks (and locations), identification of servicing mission system and detailed objectives, functional/operational requirements analyses of multiple servicing scenarios, assessment of critical servicing technology capabilities and development of an evolutionary capability plan, design and validation of selected servicing technology development missions (TDMs), identification of space station satellite servicing accommodation needs, and the cost and schedule implications of acquiring both required technology capability development and conducting the selected TDMs.

  16. What Do They Understand? Using Technology to Facilitate Formative Assessment

    Science.gov (United States)

    Mitten, Carolyn; Jacobbe, Tim; Jacobbe, Elizabeth

    2017-01-01

    Formative assessment is so important to inform teachers' planning. A discussion of the benefits of using technology to facilitate formative assessment explains how four primary school teachers adopted three different apps to make their formative assessment more meaningful and useful.

  17. Bioimpedance Spectroscopy for Assessment of Volume Status in Patients before and after General Anaesthesia

    Science.gov (United States)

    Ernstbrunner, Matthäus; Kostner, Lisa; Kimberger, Oliver; Wabel, Peter; Säemann, Marcus; Markstaller, Klaus; Fleischmann, Edith; Kabon, Barbara; Hecking, Manfred

    2014-01-01

    Background Technically assisted assessment of volume status before surgery may be useful to direct intraoperative fluid administration. We therefore tested a recently developed whole-body bioimpedance spectroscopy device to determine pre- to postoperative fluid distribution. Methods Using a three-compartment physiologic tissue model, the body composition monitor (BCM, Fresenius Medical Care, Germany) measures total body fluid volume, extracellular volume, intracellular volume and fluid overload as surplus or deficit of ‘normal’ extracellular volume. BCM-measurements were performed before and after standardized general anaesthesia for gynaecological procedures (laparotomies, laparoscopies and vaginal surgeries). BCM results were blinded to the attending anaesthesiologist and data analysed using the 2-sided, paired Student’s t-test and multiple linear regression. Results In 71 females aged 45±15 years with body weight 67±13 kg and duration of anaesthesia 154±68 min, pre- to postoperative fluid overload increased from −0.7±1.1 L to 0.1±1.0 L, corresponding to −5.1±7.5% and 0.8±6.7% of normal extracellular volume, respectively (both p<0.001), after patients had received 1.9±0.9 L intravenous crystalloid fluid. Perioperative urinary excretion was 0.4±0.3 L. The increase in extracellular volume was paralleled by an increase in total body fluid volume, while intracellular volume increased only slightly and without reaching statistical significance (p = 0.15). Net perioperative fluid balance (administered fluid volume minus urinary excretion) was significantly associated with change in extracellular volume (r2 = 0.65), but was not associated with change in intracellular volume (r2 = 0.01). Conclusions Routine intraoperative fluid administration results in a significant, and clinically meaningful increase in the extracellular compartment. BCM-measurements yielded plausible results and may become useful to guide intraoperative fluid therapy in

  18. In Situ Remediation Integrated Program, Evaluation and assessment of containment technology

    International Nuclear Information System (INIS)

    Gerber, M.A.; Fayer, M.J.

    1994-04-01

    The In Situ Remediation Integrated Program (ISRIP) was established by the US Department of Energy (DOE) to advance the state-of-the art of innovative in situ remediation technologies to the point of demonstration and to broaden the applicability of these technologies to the widely varying site remediation requirements throughout the DOE complex. This program complements similar ongoing integrated demonstration programs being conducted at several DOE sites. The ISRIP has been conducting baseline assessments on in situ technologies to support program planning. Pacific Northwest Laboratory conducted an assessment and evaluation of subsurface containment barrier technology in support of ISRIP's Containment Technology Subprogram. This report summarizes the results of that activity and provides a recommendation for priortizing areas in which additional research and development is needed to advance the technology to the point of demonstration in support of DOE's site restoration activities

  19. Data for the screening assessment. Volume 2: Appendices, Columbia River Comprehensive Impact Assessment

    International Nuclear Information System (INIS)

    Miley, T.B.; O'Neil, T.K.; Gilbert, R.O.; Klevgard, L.A.; Walters, T.B.

    1996-06-01

    The Columbia River is a critical resource for residents of the Pacific Northwest. This resource drew the Manhattan Project's planners to the site now called Hanford to produce nuclear weapon materials. Production of those materials has left behind a legacy of chemical and radioactive contamination and materials that have, are, and will continue to pose a threat to the Columbia river for the foreseeable future. To evaluate the impact to the river from this Hanford-derived contamination, the US Department of Energy, US Environmental Protection Agency, and State of Washington Department of Ecology (the Tri-Party agencies) initiated a study referred to as the Columbia River Comprehensive Impact Assessment (CRCIA). To address concerns about the scope and direction of CRCIA as well as enhance regulator, stakeholder, tribal, and public involvement, the CRCIA Management Team was formed in August 1995. A major CRCIA Team decision was to organize CRCIA into phases, with additional phases to be identified as warranted after completion of the initial phase. The initial phase is comprised of two parts: (1) a screening assessment to evaluate the current impact to the river resulting from Hanford-derived contamination and (2) identification of requirements considered necessary by the CRCIA Management Team for a comprehensive assessment of impact to the river. The purpose of the screening assessment is to support cleanup decisions. The scope of the screening assessment is to evaluate the current risk to humans and the environment resulting from Hanford-derived contaminants. The screening assessment has the primary components of: identifying contaminants to be assessed; identifying a variety of exposure scenarios to evaluate human contaminant exposure; identifying a variety of other species to evaluate ecological contaminant exposure; and assessing risks posed by exposure of humans and other species to the contaminants. This volume compiles the data from this study

  20. MoDOT pavement preservation research program volume V, site-specific pavement condition assessment.

    Science.gov (United States)

    2015-11-01

    The overall objective of Task 4 was to thoroughly assess the cost-effectiveness and utility of selected non-invasive technologies as : applicable to MoDOT roadways. Non-invasive imaging technologies investigated in this project were Ultrasonic Surfac...

  1. Oak Ridge National Laboratory Technology Logic Diagram. Volume 1, Technology Evaluation: Part A, Decontamination and Decommissioning

    Energy Technology Data Exchange (ETDEWEB)

    1993-09-01

    The Strategic Roadmap for the Oak Ridge Reservation is a generalized planning document that identifies broad categories of issues that keep ORNL outside full compliance with the law and other legally binding agreements. Possible generic paths to compliance, issues, and the schedule for resolution of the issues one identified. The role of the Oak Ridge National Laboratory Technology Logic Diagram (TLD) is then to identify specific site issues (problems), identify specific technologies that can be brought to bear on the issues, and assess the current status and readiness of these remediation technologies within the constraints of the schedule commitment. Regulatory requirements and commitments contained in the Strategic Roadmap for the Oak Ridge Reservation are also included in the TLD as constraints to the application of immature technological solutions. Some otherwise attractive technological solutions may not be employed because they may not be deployable on the schedule enumerated in the regulatory agreements. The roadmap for ORNL includes a list of 46 comprehensive logic diagrams for WM of low-level, radioactive-mixed, hazardous, sanitary and industrial. and TRU waste. The roadmapping process gives comparisons of the installation as it exists to the way the installation should exist under full compliance. The identification of the issues is the goal of roadmapping. This allows accurate and timely formulation of activities.

  2. Health technology assessment, value-based decision making, and innovation.

    Science.gov (United States)

    Henshall, Chris; Schuller, Tara

    2013-10-01

    Identifying treatments that offer value and value for money is becoming increasingly important, with interest in how health technology assessment (HTA) and decision makers can take appropriate account of what is of value to patients and to society, and in the relationship between innovation and assessments of value. This study summarizes points from an Health Technology Assessment International (HTAi) Policy Forum discussion, drawing on presentations, discussions among attendees, and background papers. Various perspectives on value were considered; most place patient health at the core of value. Wider elements of value comprise other benefits for: patients; caregivers; the health and social care systems; and society. Most decision-making systems seek to take account of similar elements of value, although they are assessed and combined in different ways. Judgment in decisions remains important and cannot be replaced by mathematical approaches. There was discussion of the value of innovation and of the effects of value assessments on innovation. Discussion also included moving toward "progressive health system decision making," an ongoing process whereby evidence-based decisions on use would be made at various stages in the technology lifecycle. Five actions are identified: (i) development of a general framework for the definition and assessment of value; development by HTA/coverage bodies and regulators of (ii) disease-specific guidance and (iii) further joint scientific advice for industry on demonstrating value; (iv) development of a framework for progressive licensing, usage, and reimbursement; and (v) promoting work to better adapt HTA, coverage, and procurement approaches to medical devices.

  3. Adjusting to Change. Technology and the American Economy, Appendix, Volume III.

    Science.gov (United States)

    National Commission on Technology, Automation and Economic Progress, Washington, DC.

    Seven studies dealing with adjustment to technological change which were done by independent experts are presented. "Programs in Aid of the Poor," by Sar A. Levitan assesses the state of social insurance, public assistance, the poverty program and other assistance to the poor and compares them to current proposals as the negative income…

  4. X-ray cone beam microtomography for quantitative assessment of tracheal and pharyngeal volumes of Rhodnius prolixus

    International Nuclear Information System (INIS)

    Souza, Izabella Soares de

    2017-01-01

    In the past decade microcomputerized tomography imaging using synchrotron radiation has become a powerful technique to generate high resolution images of Rhodinus prolixus. Images of soft tissues (protocerebrum and muscles) and dense structures (pharynx, trachea and esophagus) of R. prolixus head have been obtained using synchrotron radiation microtomography in mono and polychromatic configuration, respectively. Advancements in conventional microtomography have increased the achievable resolution and contrast, making this relatively inexpensive and widely available technology potentially useful for studies of insect internal morphology. The main goal of this work was to provide a new set of high quality microtomographic images of R. prolixus achieved by means of a desktop X-ray microtomograph. It allows the three-dimensional visualization of important chitinized structures: pharynx and tracheae. Pharyngeal and tracheal volumes were quantitatively evaluated at different days (1, 4, 10, 15 and 20) after feeding. The results suggest that variation of average volumes could be attributed to insect hormone 20-hydroxy-ecdysone (20-OH-Ec) pulse at 11 days after feeding. Pharyngeal volumes decrease 3.80 times. On the other hand, tracheal volumes increase 1.78 times. Head total volume showed similar trends than trachea. (author)

  5. Independent Orbiter Assessment (IOA): Assessment of the main propulsion subsystem FMEA/CIL, volume 4

    Science.gov (United States)

    Slaughter, B. C.

    1988-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Main Propulsion System (MPS) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were than compared to available data from the Rockwell Downey/NASA JSC FMEA/CIL review. Volume 4 contains the IOA analysis worksheets and the NASA FMEA to IOA worksheet cross reference and recommendations.

  6. Independent Orbiter Assessment (IOA): Assessment of the main propulsion subsystem FMEA/CIL, volume 3

    Science.gov (United States)

    Holden, K. A.

    1988-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Main Propulsion System (MPS) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to available data from the Rockwell Downey/NASA JSC FMEA/CIL review. Volume 3 continues the presentation of IOA worksheets and includes the potential critical items list.

  7. Information Technology Sector Baseline Risk Assessment

    Science.gov (United States)

    2009-08-01

    alternative root be economically advantageous , an actor’s ability to exploit market forces and create an alternative root would be significantly improved...conduct their operations. Therefore, a loss or disruption to Internet services would not be advantageous for the desired outcomes of these syndicates.26... eCommerce Service loss or disruption [C] Traffic Redirection [C] = Undesired consequence Information Technology Sector Baseline Risk Assessment

  8. Health technology assessment to optimize health technology utilization: using implementation initiatives and monitoring processes.

    Science.gov (United States)

    Frønsdal, Katrine B; Facey, Karen; Klemp, Marianne; Norderhaug, Inger Natvig; Mørland, Berit; Røttingen, John-Arne

    2010-07-01

    The way in which a health technology is used in any particular health system depends on the decisions and actions of a variety of stakeholders, the local culture, and context. In 2009, the HTAi Policy Forum considered how health technology assessment (HTA) could be improved to optimize the use of technologies (in terms of uptake, change in use, or disinvestment) in such complex systems. In scoping, it was agreed to focus on initiatives to implement evidence-based guidance and monitoring activities. A review identified systematic reviews of implementation initiatives and monitoring activities. A two-day deliberative workshop was held to discuss key papers, members' experiences, and collectively address key questions. This consensus paper was developed by email and finalized at a postworkshop meeting. Evidence suggests that the impact and use of HTA could be increased by ensuring timely delivery of relevant reports to clearly determined policy receptor (decision-making) points. To achieve this, the breadth of assessment, implementation initiatives such as incentives and targeted, intelligent dissemination of HTA result, needs to be considered. HTA stakeholders undertake a variety of monitoring activities, which could inform optimal use of a technology. However, the quality of these data varies and is often not submitted to an HTA. Monitoring data should be sufficiently robust so that they can be used in HTA to inform optimal use of technology. Evidence-based implementation initiatives should be developed for HTA, to better inform decision makers at all levels in a health system about the optimal use of technology.

  9. The political economy of the assessment of value of new health technologies.

    Science.gov (United States)

    Karnon, Jonathan; Edney, Laura; Afzali, Hossein

    2018-04-01

    Health technology assessment provides a common framework for evaluating the costs and benefits of new health technologies to inform decisions on the public funding of new pharmaceuticals and other health technologies. In Australia and England, empirical analyses of the opportunity costs of government spending on new health technologies suggest more quality adjusted life years are being forgone than are being gained by a non-trivial proportion of funded health technologies. This essay considers the relevance of available empirical estimates of opportunity costs and explores the relationship between the public funding of health technologies and broader political and economic factors. We conclude that the benefits of a general reduction in the prices paid by governments for new technologies outweigh the costs, but evidence of informed public acceptance of reduced access to new health technologies may be required to shift the current approach to assessing the value of new health technologies.

  10. Mixed Waste Integrated Program: A technology assessment for mercury-containing mixed wastes

    International Nuclear Information System (INIS)

    Perona, J.J.; Brown, C.H.

    1993-03-01

    The treatment of mixed wastes must meet US Environmental Protection Agency (EPA) standards for chemically hazardous species and also must provide adequate control of the radioactive species. The US Department of Energy (DOE) Office of Technology Development established the Mixed Waste Integrated Program (MWIP) to develop mixed-waste treatment technology in support of the Mixed Low-Level Waste Program. Many DOE mixed-waste streams contain mercury. This report is an assessment of current state-of-the-art technologies for mercury separations from solids, liquids, and gases. A total of 19 technologies were assessed. This project is funded through the Chemical-Physical Technology Support Group of the MWIP

  11. Decision Gate Process for Assessment of a NASA Technology Development Portfolio

    Science.gov (United States)

    Kohli, Rajiv; Fishman, Julianna L.; Hyatt, Mark J.

    2012-01-01

    The NASA Dust Management Project (DMP) was established to provide technologies (to Technology Readiness Level (TRL) 6) required to address adverse effects of lunar dust to humans and to exploration systems and equipment, to reduce life cycle cost and risk, and to increase the probability of sustainable and successful lunar missions. The technology portfolio of DMP consisted of different categories of technologies whose final product was either a technology solution in itself, or one that contributes toward a dust mitigation strategy for a particular application. A Decision Gate Process (DGP) was developed to assess and validate the achievement and priority of the dust mitigation technologies as the technologies progress through the development cycle. The DGP was part of continuous technology assessment and was a critical element of DMP risk management. At the core of the process were technology-specific criteria developed to measure the success of each DMP technology in attaining the technology readiness levels assigned to each decision gate. The DGP accounts for both categories of technologies and qualifies the technology progression from technology development tasks to application areas. The process provided opportunities to validate performance, as well as to identify non-performance in time to adjust resources and direction. This paper describes the overall philosophy of the DGP and the methodology for implementation for DMP, and describes the method for defining the technology evaluation criteria. The process is illustrated by example of an application to a specific DMP technology.

  12. Technology assessment of various coal-fuel options

    International Nuclear Information System (INIS)

    Coenen, R.; Findling, B.; Klein-Vielhauer, S.; Nieke, E.; Paschen, H.; Tangen, H.; Wintzer, D.

    1991-01-01

    The technology assessment (TA) study of coal-based fuels presented in this report was performed for the Federal Ministry for Research and Technology. Its goal was to support decision-making of the Federal Ministry for Research and Technology in the field of coal conversion. Various technical options of coal liquefaction have been analyzed on the basis of hard coal as well as lignite -- direct liquefaction of coal (hydrogenation) and different possibilities of indirect liquefaction, that is the production of fuels (methanol, gasoline) by processing products of coal gasification. The TA study takes into consideration the entire technology chain from coal mining via coal conversion to the utilization of coal-based fuels in road transport. The analysis focuses on costs of the various options, overall economic effects, which include effects on employment and public budgets, and on environmental consequences compared to the use of liquid fuels derived from oil. Furthermore, requirements of infrastructure and other problems of the introduction of coal-based fuels as well as prospects for the export of technologies of direct and indirect coal liquefaction have been analyzed in the study. 14 figs., 10 tabs

  13. Technical and economic assessment of fluidized bed augmented compressed air energy storage system. Volume III. Preconceptual design

    Energy Technology Data Exchange (ETDEWEB)

    Giramonti, A.J.; Lessard, R.D.; Merrick, D.; Hobson, M.J.

    1981-09-01

    A technical and economic assessment of fluidized bed combustion augmented compressed air energy storage systems is presented. The results of this assessment effort are presented in three volumes. Volume III - Preconceptual Design contains the system analysis which led to the identification of a preferred component configuration for a fluidized bed combustion augmented compressed air energy storage system, the results of the effort which transformed the preferred configuration into preconceptual power plant design, and an introductory evaluation of the performance of the power plant system during part-load operation and while load following.

  14. BBN-Based Portfolio Risk Assessment for NASA Technology R&D Outcome

    Science.gov (United States)

    Geuther, Steven C.; Shih, Ann T.

    2016-01-01

    The NASA Aeronautics Research Mission Directorate (ARMD) vision falls into six strategic thrusts that are aimed to support the challenges of the Next Generation Air Transportation System (NextGen). In order to achieve the goals of the ARMD vision, the Airspace Operations and Safety Program (AOSP) is committed to developing and delivering new technologies. To meet the dual challenges of constrained resources and timely technology delivery, program portfolio risk assessment is critical for communication and decision-making. This paper describes how Bayesian Belief Network (BBN) is applied to assess the probability of a technology meeting the expected outcome. The network takes into account the different risk factors of technology development and implementation phases. The use of BBNs allows for all technologies of projects in a program portfolio to be separately examined and compared. In addition, the technology interaction effects are modeled through the application of object-oriented BBNs. The paper discusses the development of simplified project risk BBNs and presents various risk results. The results presented include the probability of project risks not meeting success criteria, the risk drivers under uncertainty via sensitivity analysis, and what-if analysis. Finally, the paper shows how program portfolio risk can be assessed using risk results from BBNs of projects in the portfolio.

  15. Organizational analysis and safety for utilities with nuclear power plants: perspectives for organizational assessment. Volume 2. [PWR; BWR

    Energy Technology Data Exchange (ETDEWEB)

    Osborn, R.N.; Olson, J.; Sommers, P.E.; McLaughlin, S.D.; Jackson, M.S.; Nadel, M.V.; Scott, W.G.; Connor, P.E.; Kerwin, N.; Kennedy, J.K. Jr.

    1983-08-01

    This two-volume report presents the results of initial research on the feasibility of applying organizational factors in nuclear power plant (NPP) safety assessment. Volume 1 of this report contains an overview of the literature, a discussion of available safety indicators, and a series of recommendations for more systematically incorporating organizational analysis into investigations of nuclear power plant safety. The six chapters of this volume discuss the major elements in our general approach to safety in the nuclear industry. The chapters include information on organizational design and safety; organizational governance; utility environment and safety related outcomes; assessments by selected federal agencies; review of data sources in the nuclear power industry; and existing safety indicators.

  16. THREE-DIMENSIONAL ASSESSMENT OF THE PHARYNGEAL AIRWAY AND MAXILLARY SINUS VOLUMES IN INDIVIDUALS WITH NON-SYNDROMIC CLEFT LIP AND PALATE

    Directory of Open Access Journals (Sweden)

    Ana NEMȚOI

    2015-09-01

    Full Text Available Introduction: Children with cleft lip and palate (CLP are known to have airway problems. Introduction of ConeBeam CT (CBCT and imaging software has facilitated generation of 3D images for assessing the volume of maxillary sinuses and pharyngeal airway. Consequently, the present study aimed at evaluating and comparing the maxillary sinus and pharyngeal airway volume of patients with cleft lip and palate in healthy patients, using cone beam computed tomography (CBCT images. Materials and method: The sample group included 27 individuals (15 with cleft lip and palate subjects and 12 healthy subjects. The pharyngeal airway and each maxillary sinus were three-dimensionally assessed, segmented and their volume was calculated. A comparison between the right and left sinus was performed by Student t-test, and the differences between the control and cleft groups were calculated using ANOVA. Results: No statistically significant differences were found when the maxillary sinuses volumes from each side were compared (p >0.05. The unilateral CLP patients presented the lowest sinus volume. Individuals with CLP did not exhibit a total airway volume smaller than the nonCLP controls. Conclusions: 3D imaging using CBCT and Romexis software is reliable for assessing maxillary sinus and pharyngeal airway volume. The present study showed that the pharyngeal airway is not compromised in CLP individuals. The unilateral CLP individuals present maxillary sinuses with smaller volumes, no differences being recorded between the cleft and non-cleft side.

  17. Amniotic fluid volume: Rapid MR-based assessment at 28-32 weeks gestation

    Energy Technology Data Exchange (ETDEWEB)

    Hilliard, N.J.; Hawkes, R.; Patterson, A.J.; Graves, M.J.; Priest, A.N.; Hunter, S.; Set, P.A.; Lomas, D.J. [Cambridge University Hospitals NHS Foundation Trust, Department of Radiology, Cambridge (United Kingdom); Lees, C. [Imperial College Healthcare NHS Trust, Department of Obstetrics and Fetal Medicine, London (United Kingdom)

    2016-10-15

    This work evaluates rapid magnetic resonance projection hydrography (PH) based amniotic fluid volume (AFV) estimates against established routine ultrasound single deepest vertical pocket (SDVP) and amniotic fluid index (AFI) measurements, in utero at 28-32 weeks gestation. Manual multi-section planimetry (MSP) based measurement of AFV is used as a proxy reference standard. Thirty-five women with a healthy singleton pregnancy (20-41 years) attending routine antenatal ultrasound were recruited. SDVP and AFI were measured using ultrasound, with same day MRI assessing AFV with PH and MSP. The relationships between the respective techniques were assessed using linear regression analysis and Bland-Altman method comparison statistics. When comparing estimated AFV, a highly significant relationship was observed between PH and the reference standard MSP (R{sup 2} = 0.802, p < 0.001). For the US measurements, SDVP measurement related most closely to amniotic fluid volume, (R{sup 2} = 0.470, p < 0.001), with AFI demonstrating a weaker relationship (R{sup 2} = 0.208, p = 0.007). This study shows that rapid MRI based PH measurement is a better predictor of AFV, relating more closely to our proxy standard than established US techniques. Although larger validation studies across a range of gestational ages are required this approach could form part of MR fetal assessment, particularly where poly- or oligohydramnios is suspected. (orig.)

  18. Amniotic fluid volume: Rapid MR-based assessment at 28-32 weeks gestation

    International Nuclear Information System (INIS)

    Hilliard, N.J.; Hawkes, R.; Patterson, A.J.; Graves, M.J.; Priest, A.N.; Hunter, S.; Set, P.A.; Lomas, D.J.; Lees, C.

    2016-01-01

    This work evaluates rapid magnetic resonance projection hydrography (PH) based amniotic fluid volume (AFV) estimates against established routine ultrasound single deepest vertical pocket (SDVP) and amniotic fluid index (AFI) measurements, in utero at 28-32 weeks gestation. Manual multi-section planimetry (MSP) based measurement of AFV is used as a proxy reference standard. Thirty-five women with a healthy singleton pregnancy (20-41 years) attending routine antenatal ultrasound were recruited. SDVP and AFI were measured using ultrasound, with same day MRI assessing AFV with PH and MSP. The relationships between the respective techniques were assessed using linear regression analysis and Bland-Altman method comparison statistics. When comparing estimated AFV, a highly significant relationship was observed between PH and the reference standard MSP (R"2 = 0.802, p < 0.001). For the US measurements, SDVP measurement related most closely to amniotic fluid volume, (R"2 = 0.470, p < 0.001), with AFI demonstrating a weaker relationship (R"2 = 0.208, p = 0.007). This study shows that rapid MRI based PH measurement is a better predictor of AFV, relating more closely to our proxy standard than established US techniques. Although larger validation studies across a range of gestational ages are required this approach could form part of MR fetal assessment, particularly where poly- or oligohydramnios is suspected. (orig.)

  19. Assessment and prognosis of environmental state and development of environmentally effective technologies

    International Nuclear Information System (INIS)

    Golovko, A.; Polichtchouk, Y.; Ivanov, V.

    2002-01-01

    Despite of the decrease in oil production in Russia, the negative effects of the oil industry wastes on the environment still remain. The authors examine the main sources of the environmental pollution and suggest the assessment of technogenic impact which requires large volumes of ecological, cartographic and other data through the application of geographic information systems (GIS). Suggested technology includes software means for simulating the technogenic impact on natural environment. By overlapping the zones of technogenic impact on the landscape map using GIS, the relative areas of the polluted landscape complexes can be calculated. A developed method for oil product containment in water surface based on natural and synthetic fibrous adsorbents is presented. The isotherms of adsorption of oil, diesel fuel and gasoline are given. The efficiency of water purification from the oil products in solutions depends of their initial concentrations. The efficiency of adsorption from the microemulsions, however, increases with increasing adsorbent-solution ratio. The efficiency of the purification of oily sewage may be evaluated using the data in the Table obtained for oil products adsorption on multilayered adsorbents. (YU-INIS Centre)

  20. Technology-enabled assessment of health professions education: consensus statement and recommendations from the Ottawa 2010 Conference

    DEFF Research Database (Denmark)

    Amin, Zubair; Boulet, John R; Cook, David A

    2011-01-01

    The uptake of information and communication technologies (ICTs) in health professions education can have far-reaching consequences on assessment. The medical education community still needs to develop a deeper understanding of how technology can underpin and extend assessment practices....... This article was developed by the 2010 Ottawa Conference Consensus Group on technology-enabled assessment to guide practitioners and researchers working in this area. This article highlights the changing nature of ICTs in assessment, the importance of aligning technology-enabled assessment with local context...... and needs, the need for better evidence to support use of technologies in health profession education assessment, and a number of challenges, particularly validity threats, that need to be addressed while incorporating technology in assessment. Our recommendations are intended for all practitioners across...

  1. Volume and Surface-Enhanced Volume Negative Ion Sources

    International Nuclear Information System (INIS)

    Stockli, M P

    2013-01-01

    H - volume sources and, especially, caesiated H - volume sources are important ion sources for generating high-intensity proton beams, which then in turn generate large quantities of other particles. This chapter discusses the physics and technology of the volume production and the caesium-enhanced (surface) production of H - ions. Starting with Bacal's discovery of the H - volume production, the chapter briefly recounts the development of some H - sources, which capitalized on this process to significantly increase the production of H - beams. Another significant increase was achieved in the 1990s by adding caesiated surfaces to supplement the volume-produced ions with surface-produced ions, as illustrated with other H - sources. Finally, the focus turns to some of the experience gained when such a source was successfully ramped up in H - output and in duty factor to support the generation of 1 MW proton beams for the Spallation Neutron Source. (author)

  2. Review of early assessment models of innovative medical technologies.

    Science.gov (United States)

    Fasterholdt, Iben; Krahn, Murray; Kidholm, Kristian; Yderstræde, Knud Bonnet; Pedersen, Kjeld Møller

    2017-08-01

    Hospitals increasingly make decisions regarding the early development of and investment in technologies, but a formal evaluation model for assisting hospitals early on in assessing the potential of innovative medical technologies is lacking. This article provides an overview of models for early assessment in different health organisations and discusses which models hold most promise for hospital decision makers. A scoping review of published studies between 1996 and 2015 was performed using nine databases. The following information was collected: decision context, decision problem, and a description of the early assessment model. 2362 articles were identified and 12 studies fulfilled the inclusion criteria. An additional 12 studies were identified and included in the review by searching reference lists. The majority of the 24 early assessment studies were variants of traditional cost-effectiveness analysis. Around one fourth of the studies presented an evaluation model with a broader focus than cost-effectiveness. Uncertainty was mostly handled by simple sensitivity or scenario analysis. This review shows that evaluation models using known methods assessing cost-effectiveness are most prevalent in early assessment, but seems ill-suited for early assessment in hospitals. Four models provided some usable elements for the development of a hospital-based model. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  3. Health technology assessment (HTA): definition, role and use in the changing healthcare environment.

    Science.gov (United States)

    Gallio, D; Berto, P

    2007-01-01

    The increasing availability of health care technology--boosted by considerable advances in areas like biotechnology, biomaterials, surgical techniques and computer technology--has accompanied burgeoning health care costs, and for this reason an increasing number of subjects (clinicians, health product makers, regulators, patients, hospitals, managers, payers, government leaders) demand for well-founded information to support decisions about development, adoption, acquisition and use of new and existing technologies. Technology assessment is a form of policy research that identifies policy issues, assesses the impact of alternative courses of action, and presents findings. This article is aimed at describing the historical development, reviewing the various definition and classifications, illustrating the purposes Fnd actors of Health Technology Assessment and its possible applications in the current healthcare scenario.

  4. Research on simulation technology for CBRN threat assessment system. Prediction technology for atmospheric dispersion of CBRN materials

    International Nuclear Information System (INIS)

    Miura, Hiroaki; Yano, Masanori; Nakata, Mitsuhiro; Takeda, Masaki

    2013-01-01

    The technical survey is conducted on the CBRN (Chemical, Biological, Radiological and Nuclear) Threat Assessment System Simulation Technology. The dispersion property of CBRN materials is summarized, and the current simulation techniques for CBRN materials dispersion are described. The effects of advection-diffusion, sedimentation by the gravity, buoyancy and wash-out by rainfall on the dispersion property of CBRN materials should be considered in the simulation modeling. The concentration distribution of CBRN materials is predicted through the meteorological analysis, the flow analysis and the dispersion analysis, and the hazard map will be produced from that. A selection of simulation method, model, domain and number of computational grid points is necessary to perform the simulation, considering the balance between calculation cost and prediction accuracy. For construction of CBRN Threat Assessment System, it is important how to integrate the developed simulation element technologies and threat assessment technologies. (author)

  5. An assessment of information communication technology content ...

    African Journals Online (AJOL)

    An assessment of information communication technology content, context and ... a- vis the upscaling of ICT in health care facilities in Nairobi and Machakos counties. ... high in all the facilities compared to levels of services operations computerised and ... for Authors · for Policy Makers · about Open Access · Journal Quality.

  6. Revisiting the relationship between tumour volume and diameter in advanced NSCLC patients: An exercise to maximize the utility of each measure to assess response to therapy

    International Nuclear Information System (INIS)

    Nishino, M.; Jackman, D.M.; DiPiro, P.J.; Hatabu, H.; Jänne, P.A.; Johnson, B.E.

    2014-01-01

    Aim: To revisit the presumed relationship between tumour diameter and volume in advanced non-small-cell lung cancer (NSCLC) patients, and determine whether the measured volume using volume-analysis software and its proportional changes during therapy matches with the calculated volume obtained from the presumed relationship and results in concordant response assessment. Materials and methods: Twenty-three patients with stage IIIB/IV NSCLC with a total of 53 measurable lung lesions, treated in a phase II trial of erlotinib, were studied with institutional review board approval. Tumour volume and diameter were measured at baseline and at the first follow-up computed tomography (CT) examination using volume-analysis software. Using the measured diameter (2r) and the equation, calculated volume was obtained as (4/3)πr 3 at baseline and at the follow-up. Percent volume change was obtained by comparing to baseline for measured and calculated volumes, and response assessment was assigned. Results: The measured volume was significantly smaller than the calculated volume at baseline (median 11,488.9 mm 3 versus 17,148.6 mm 3 ; p < 0.0001), with a concordance correlation coefficient (CCC) of 0.7022. At follow-up, the measured volume was once again significantly smaller than the calculated volume (median 6573.5 mm 3 versus 9198.1 mm 3 ; p = 0.0022), with a CCC of 0.7408. Response assessment by calculated versus measured volume changes had only moderate agreement (weighted κ = 0.545), with discordant assessment results in 20% (8/40) of lesions. Conclusion: Calculated volume based on the presumed relationship significantly differed from the measured volume in advanced NSCLC patients, with only moderate concordance in response assessment, indicating the limitations of presumed relationship. - Highlights: • Response assessment by measured vs calculated values has only moderate agreement. • It is important to obtain the actual measured values for tumor response

  7. Cost, Time, and Risk Assessment of Different Wave Energy Converter Technology Development Trajectories: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Weber, Jochem W [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Laird, Daniel [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Costello, Ronan [Wave Venture; Roberts, Jesse [Sandia National Laboratories; Bull, Diana [Sandia National Laboratories; Babarit, Aurelien [Ecole Centrale de Nantes; Nielsen, Kim [Ramboll; Ferreira, Claudio Bittencourt [DNV-GL; Kennedy, Ben [Wave Venture

    2017-09-14

    This paper presents a comparative assessment of three fundamentally different wave energy converter technology development trajectories. The three technology development trajectories are expressed and visualised as a function of technology readiness levels and technology performance levels. The assessment shows that development trajectories that initially prioritize technology readiness over technology performance are likely to require twice the development time, consume a threefold of the development cost, and are prone to a risk of technical or commercial failure of one order of magnitude higher than those development trajectories that initially prioritize technology performance over technology readiness.

  8. Decentralized peri-urban wastewater treatment technologies assessment integrating sustainability indicators.

    Science.gov (United States)

    Mena-Ulecia, Karel; Hernández, Heykel Hernández

    2015-01-01

    Selection of treatment technologies without considering the environmental, economic and social factors associated with each geographical context risks the occurrence of negative impacts that were not properly foreseen, working against the sustainable performance of the technology. The principal aim of this study was to evaluate 12 technologies for decentralized treatment of domestic wastewater applicable to peri-urban communities using sustainability approaches and, at the same time, continuing a discussion about how to address a more integrated assessment of overall sustainability. For this, a set of 13 indicators that embody the environmental, economic and social approach for the overall sustainability assessment were used by means of a target plot diagram as a tool for integrating indicators that represent a holistic analysis of the technologies. The obtained results put forward different degrees of sustainability, which led to the selection of: septic tank+land infiltration; up-flow anaerobic reactor+high rate trickling filter and septic tank+anaerobic filter as the most sustainable and attractive technologies to be applied in peri-urban communities, according to the employed indicators.

  9. Ethically sound technology? Guidelines for interactive ethical assessment of personal health monitoring.

    Science.gov (United States)

    Palm, Elin; Nordgren, Anders; Verweij, Marcel; Collste, Göran

    2013-01-01

    Novel care-technologies possess a transformational potential. Future care and support may be provided via monitoring technologies such as smart devices, sensors, actors (robots) and Information and Communication Technologies. Such technologies enable care provision outside traditional care institutions, for instance in the homes of patients. Health monitoring may become "personalized" i.e. tailored to the needs of individual care recipients' but may also alter relations between care providers and care recipents, shape and form the care environment and influence values central to health-care. Starting out from a social constructivist theory of technology, an interactive ethical assessment-model is offered. The suggested model supplements a traditional analysis based on normative ethical theory (top-down approach) with interviews including relevant stakeholders (a bottom-up approach). This method has been piloted by small-scale interviews encircling stakeholder perspectives on three emerging technologies: (1) Careousel, a smart medicine-management device, (2) Robot Giraff, an interactive and mobile communication-device and (3) I-Care, a care-software that combines alarm and register system. By incorporating stakeholder perspectives into the analysis, the interactive ethical assessment model provides a richer understanding of the impact of PHM-technologies on ethical values than a traditional top-down model. If the assessment is conducted before the technology has reached the market - preferably in close interaction with developers and users - ethically sound technologies may be obtained.

  10. An Assessment of Petroleum Technology Development Fund (Ptdf ...

    African Journals Online (AJOL)

    An Assessment of Petroleum Technology Development Fund (Ptdf) ... and other related literature were utilized to elicit information for the research. ... industry and that some of those trained lack the technical know-how to manage the refineries.

  11. European network for health technology assessment, EUnetHTA: planning, development, and implementation of a sustainable European network for health technology assessment

    DEFF Research Database (Denmark)

    Kristensen, Finn Børlum; Mäkelä, Marjukka; Neikter, Susanna Allgurin

    2009-01-01

    OBJECTIVES: The European network on Health Technology Assessment (EUnetHTA) aimed to produce tangible and practical results to be used in the various phases of health technology assessment and to establish a framework and processes to support this. This article presents the background, objectives......, and organization of EUnetHTA, which involved a total of sixty-four partner organizations. METHODS: Establishing an effective and sustainable structure for a transnational network involved many managerial, policy, and methodological tools, according to the objective of each task or Work Package. Transparency...... the use of HTA at national and regional levels. Responsiveness to political developments in Europe should be balanced with maintaining a high level of ambition to promote independent, evidence-based information and well-tested tools for best practice based on a strong network of HTA institutions....

  12. Institutionalizing Emerging Technology Assessment Process into National Incident Response

    Science.gov (United States)

    2013-10-01

    mechanical methods, devices, and products, including oil sensors, booms, skimmers, decontamination , and waste minimization technologies...handling). • Alternative Oil Spill Response Technologies (in situ burning , dispersants, etc.). • Oil Spill Damage Assessment and Restoration. The TETs...deaths of eleven crewmembers and a subsequent uncontrolled oil spill that tested the government’s ability to respond to a spill of this magnitude as

  13. The Papers Printing Quality Complex Assessment Algorithm Development Taking into Account the Composition and Production Technological Features

    Science.gov (United States)

    Babakhanova, Kh A.; Varepo, L. G.; Nagornova, I. V.; Babluyk, E. B.; Kondratov, A. P.

    2018-04-01

    Paper is one of the printing system key components causing the high-quality printed products output. Providing the printing companies with the specified printing properties paper, while simultaneously increasing the paper products range and volume by means of the forecasting methods application and evaluation during the production process, is certainly a relevant problem. The paper presents the printing quality control algorithm taking into consideration the paper printing properties quality assessment depending on the manufacture technological features and composition variation. The information system including raw material and paper properties data and making possible pulp and paper enterprises to select paper composition optimal formulation is proposed taking into account the printing process procedure peculiarities of the paper manufacturing with specified printing properties.

  14. Bioimpedance spectroscopy for assessment of volume status in patients before and after general anaesthesia.

    Directory of Open Access Journals (Sweden)

    Matthäus Ernstbrunner

    Full Text Available BACKGROUND: Technically assisted assessment of volume status before surgery may be useful to direct intraoperative fluid administration. We therefore tested a recently developed whole-body bioimpedance spectroscopy device to determine pre- to postoperative fluid distribution. METHODS: Using a three-compartment physiologic tissue model, the body composition monitor (BCM, Fresenius Medical Care, Germany measures total body fluid volume, extracellular volume, intracellular volume and fluid overload as surplus or deficit of 'normal' extracellular volume. BCM-measurements were performed before and after standardized general anaesthesia for gynaecological procedures (laparotomies, laparoscopies and vaginal surgeries. BCM results were blinded to the attending anaesthesiologist and data analysed using the 2-sided, paired Student's t-test and multiple linear regression. RESULTS: In 71 females aged 45 ± 15 years with body weight 67 ± 13 kg and Duration of anesthesia 154 ± 69 minutes [corrected] duration of anaesthesia 154 ± 68 min, pre- to postoperative fluid overload increased from -0.7 ± 1.1 L to 0.1 ± 1.0 L, corresponding to -5.1 ± 7.5% and 0.8 ± 6.7% of normal extracellular volume, respectively (both p<0.001, after patients had received 1.9 ± 0.9 L intravenous crystalloid fluid. Perioperative urinary excretion was 0.3 ± 0.2 L [corrected]. The increase in extracellular volume was paralleled by an increase in total body fluid volume, while intracellular volume increased only slightly and without reaching statistical significance (p = 0.15. Net perioperative fluid balance (administered fluid volume minus urinary excretion was significantly associated with change in extracellular volume (r(2 = 0.65, but was not associated with change in intracellular volume (r(2 = 0.01. CONCLUSIONS: Routine intraoperative fluid administration results in a significant, and clinically meaningful increase in the extracellular compartment. BCM-measurements yielded

  15. Response of left ventricular volume to exercise in man assessed by radionuclide equilibrium angiography

    International Nuclear Information System (INIS)

    Slutsky, R.; Karliner, J.; Ricci, D.; Schuler, G.; Pfisterer, M.; Peterson, K.; Ashburn, W.

    1979-01-01

    To assess the effects of exercise on left ventricular volumes we studied 10 normal men, 15 patients with coronary disease who developed angina pectoris during exercise, and 10 patients with known coronary disease who did not develop angina during exercise. Each subject performed supine bicycle exercise under a mobile, single-crystal scintillation camera until angina or fatigue occurred. Technetium-99m bound to human serum albumin was the imaging agent. Data were collected at rest and during the last 2 minutes of each 3-minute stage of exercise and for 10 minutes after exercise. Volumes were calculated by a new radionuclide technique that correlated well with cineangiography and is expressed in nondimensional units. In normal subjects, the end-diastolic volume (EDV) at rest was not different from that a peak exercise. The end-systolic volume (ESV) decreased at peak exercise. ESV decreased progressively in all but two of 30 exercise periods. Angina patients had a larger EDV at rest and during chest pain than normals. Angina patients increased their ESV during chest pain resulting in a decreased ejection fraction (EF). All angina patients had a higher ESV during chest pain than during the exercise stage before chest pain. As a group, patients who did not develop angina had a lower EDV at rest and peak exercise than those who did develop angina. We conclude: that the EF increases during exercise due to a decrease in ESV; that the EF in patients with angina decreases because of an increase in ESV; and that the EF in coronary disease patients without angina shows no change because there is no significant change in the ESV. Radionuclide equilibrium angiography may prove useful for assessing EF and volume changes in patients with coronary artery disease

  16. Proceedings of the international symposium on environmental technologies: Plasma systems and applications. Volume 1

    International Nuclear Information System (INIS)

    Mayne, P.W.; Mulholland, J.A.

    1995-01-01

    Plasma technology is an extremely versatile and powerful means of obtaining very high temperatures that can be used in a variety of environmental situations. Since most types of waste products and contaminants can be treated effectively and efficiently, plasma systems have been developed to address the disposal and annihilation domestic of medical, hazardous, radioactive, military, and miscellaneous wastes. Plasma technologies can also be implemented to recycle and recover usable materials from metallic wastes. The International Symposium on Environmental Technologies: Plasma Systems and Applications was held at the Omni Hotel in Atlanta, Georgia on October 8--12, 1995 to bring together a large group of technical experts working on the use of plasma for solving environmental problems. The Symposium is a sequel to the 1994 Metatechnies Conference on Stabilization and Volarization of Ultimate Waste by Plasma Processes that was held in September of 1994 at Bordeaux Lac, France. The proceedings to this second international conference contain the written contributions from eleven sessions and are published in two volumes. A total of 65 papers address the use of plasma systems for environmental applications and include topics concerning the development and use of innovative technologies for waste treatment, environmental remediation, recycling, characterization of the plasma and solid residue, off-gas analyses, as well as case studies and regulatory policies

  17. Prospective Technology Assessment of Synthetic Biology: Fundamental and Propaedeutic Reflections in Order to Enable an Early Assessment.

    Science.gov (United States)

    Schmidt, Jan Cornelius

    2016-08-01

    Synthetic biology is regarded as one of the key technosciences of the future. The goal of this paper is to present some fundamental considerations to enable procedures of a technology assessment (TA) of synthetic biology. To accomplish such an early "upstream" assessment of a not yet fully developed technology, a special type of TA will be considered: Prospective TA (ProTA). At the center of ProTA are the analysis and the framing of "synthetic biology," including a characterization and assessment of the technological core. The thesis is that if there is any differentia specifica giving substance to the umbrella term "synthetic biology," it is the idea of harnessing self-organization for engineering purposes. To underline that we are likely experiencing an epochal break in the ontology of technoscientific systems, this new type of technology is called "late-modern technology." -I start this paper by analyzing the three most common visions of synthetic biology. Then I argue that one particular vision deserves more attention because it underlies the others: the vision of self-organization. I discuss the inherent limits of this new type of late-modern technology in the attempt to control and monitor possible risk issues. I refer to Hans Jonas' ethics and his early anticipation of the risks of a novel type of technology. I end by drawing conclusions for the approach of ProTA towards an early societal shaping of synthetic biology.

  18. Three-dimensional reconstruction volume: a novel method for volume measurement in kidney cancer.

    Science.gov (United States)

    Durso, Timothy A; Carnell, Jonathan; Turk, Thomas T; Gupta, Gopal N

    2014-06-01

    The role of volumetric estimation is becoming increasingly important in the staging, management, and prognostication of benign and cancerous conditions of the kidney. We evaluated the use of three-dimensional reconstruction volume (3DV) in determining renal parenchymal volumes (RPV) and renal tumor volumes (RTV). We compared 3DV with the currently available methods of volume assessment and determined its interuser reliability. RPV and RTV were assessed in 28 patients who underwent robot-assisted laparoscopic partial nephrectomy for kidney cancer. Patients with a preoperative creatinine level of kidney pre- and postsurgery overestimated 3D reconstruction volumes by 15% to 102% and 12% to 101%, respectively. In addition, volumes obtained from 3DV displayed high interuser reliability regardless of experience. 3DV provides a highly reliable way of assessing kidney volumes. Given that 3DV takes into account visible anatomy, the differences observed using previously published methods can be attributed to the failure of geometry to accurately approximate kidney or tumor shape. 3DV provides a more accurate, reproducible, and clinically useful tool for urologists looking to improve patient care using analysis related to volume.

  19. Practice parameters facilitating adoption of advanced technologies for enhancing neuropsychological assessment paradigms.

    Science.gov (United States)

    Parsons, Thomas D; McMahan, Timothy; Kane, Robert

    2018-01-01

    Clinical neuropsychologists have long underutilized computer technologies for neuropsychological assessment. Given the rapid advances in technology (e.g. virtual reality; tablets; iPhones) and the increased accessibility in the past decade, there is an on-going need to identify optimal specifications for advanced technologies while minimizing potential sources of error. Herein, we discuss concerns raised by a joint American Academy of Clinical Neuropsychology/National Academy of Neuropsychology position paper. Moreover, we proffer parameters for the development and use of advanced technologies in neuropsychological assessments. We aim to first describe software and hardware configurations that can impact a computerized neuropsychological assessment. This is followed by a description of best practices for developers and practicing neuropsychologists to minimize error in neuropsychological assessments using advanced technologies. We also discuss the relevance of weighing potential computer error in light of possible errors associated with traditional testing. Throughout there is an emphasis on the need for developers to provide bench test results for their software's performance on various devices and minimum specifications (documented in manuals) for the hardware (e.g. computer, monitor, input devices) in the neuropsychologist's practice. Advances in computerized assessment platforms offer both opportunities and challenges. The challenges can appear daunting but are a manageable and require informed consumers who can appreciate the issues and ask pertinent questions in evaluating their options.

  20. Harnessing Technology to Assess Oral Communication in Business English

    Science.gov (United States)

    Levy, Tal; Gertler, Hedy

    2015-01-01

    Assessing oral skills in relatively large Business English classes seems a most formidable task for any teacher. How does one make sure to get multiple and valid assessments of each student? This action research paper provides supporting evidence for the correlation between the use of technology and students' engagement. This was achieved by…

  1. A pilot study to assess the feasibility of measurement of adrenal gland volume by magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Grant, Lee A.; Dixon, Adrian K. (Dept. of Radiology, Cambridge Univ. Teaching Hospitals NHS Foundation Trust, Cambridge (United Kingdom)), e-mail: leegrant100@gmail.com; Napolitano, Antonella; McHugh, Simon M. (GlaxoSmithKline RandD, Clinical Unit Cambridge, Addenbrooke' s Centre for Clinical Investigation, Addenbrooke' s Hospital, Cambridge (United Kingdom)); Miller, Sam (Analysis Applications Research Group, GSK RandD, Harlow, Essex (United Kingdom)); Stephens, Kimberley (Discovery Statistics, GSK RandD, Harlow, Essex (United Kingdom))

    2010-01-15

    Background: Repeated computed tomography (CT) assessment of the adrenal glands is associated with a significant radiation burden. The increasing capabilities of magnetic resonance (MR) volumetric analysis of the adrenals make this a potentially alternative technique in man. Purpose: To determine whether MR imaging could be used to measure adrenal volume, and to determine the intra- and interobserver variation and repeatability of MR volume imaging of adrenals in healthy human subjects. Material and Methods: This was a single-cohort, sequential design, three-part study involving four MRI examinations per subject following ethical approval and informed consent. Information was collected on four healthy subjects (three male and one female). Two different investigators estimated the area of the adrenal gland for each of the 3-mm contiguous slices (and consequently adrenal volume). In order to estimate inter- and intrareader variability, a repeated-measures mixed model was fitted with adrenal volume as the dependent variable. In order to estimate any bias between readers, Bland-Altman methodology was applied. Results: Intraobserver variation for adrenal gland volume is approximately 5% of a 3-cm3 adrenal gland. Interobserver variation is approximately 9% of a 3-cm3 adrenal gland. Potential variation in measurement for adrenal volume from all sources equates to approximately 14% of a 3-cm3 adrenal gland. Verification of image reading by a second investigator (consensus reading) reduces variability. Conclusion: Analysis of adrenal gland volume using MRI is a potentially reliable technique that could be used to assess a pathological change in adrenal size

  2. Assessment of the use of space technology in the monitoring of oil spills and ocean pollution: Technical volume. Executive summary

    Science.gov (United States)

    Alvarado, U. R. (Editor); Chafaris, G.; Chestek, J.; Contrad, J.; Frippel, G.; Gulatsi, R.; Heath, A.; Hodara, H.; Kritikos, H.; Tamiyasu, K.

    1980-01-01

    The potential of space systems and technology for detecting and monitoring ocean oil spills and waste pollution was assessed as well as the impact of this application on communication and data handling systems. Agencies charged with responsibilities in this area were identified and their measurement requirements were ascertained in order to determine the spatial resolution needed to characterize operational and accidental discharges. Microwave and optical sensors and sensing techniques were evaluated as candidate system elements. Capabilities are described for the following: synthetic aperture radar, microwave scatterometer, passive microwave radiometer, microwave altimeter, electro-optical sensors currently used in airborne detection, existing space-based optical sensors, the thematic mapper, and the pointable optical linear array.

  3. Human factors assessments of D and D technologies

    International Nuclear Information System (INIS)

    Carpenter, C.P.; Evans, T.T.; McCabe, B.

    2000-01-01

    On April 2, 1997, the US Secretary of Energy directed the US Assistant Secretary of Environmental Management and of Safety and Health to require field input of appropriate data to ensure that safety and health considerations were properly addressed in the Accelerating Cleanup: Focus on 2006 Plan. The US Department of Energy (DOE) field managers have committed to the Secretary that they will fully implement integrated safety management systems (ISMSs) at their respective sites by the end of fiscal year 1999. The Secretary has further directed that headquarters safety and health guidance be developed to support consistent and comprehensive project baseline summaries from the field. The Secretary has committed to institutionalizing ISMS as an integral component of the way the DOE conducts its business. The Defense Nuclear Facilities Safety Board continues to oversee and closely monitor the DOE's commitment to the safety and health of its workers. The DOE is committed to a management system approach to ensure that work is performed in a manner that protects the worker, public, and environment. The Deactivation and Decommissioning Focus Area (DDFA) is actively addressing the need to incorporate environmental safety and health (ES and H) considerations in developing technologies. The DDFA is partnered with the Operating Engineers National Hazmat Program (OENHP) to evaluate the ES and H considerations of the innovative and improved decontamination and decommissioning technologies. Part of the implementation of the ES and H work practices in the field is through a cooperative agreement between the National Energy Technology Laboratory (NETL) and the OENHP. The objective of this program is to establish an International Environmental Technology and Training Center to conduct human factors assessments and protocols on environmental technologies. The intent of the human factors assessments is to enhance the effectiveness and efficiency of the technologies and to enhance

  4. Technology Assessment for Powertrain Components Final Report CRADA No. TC-1124-95

    Energy Technology Data Exchange (ETDEWEB)

    Tokarz, F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Gough, C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-10-19

    LLNL utilized its defense technology assessment methodologies in combination with its capabilities in the energy; manufacturing, and transportation technologies to demonstrate a methodology that synthesized available but incomplete information on advanced automotive technologies into a comprehensive framework.

  5. Sudbury soils study : summary of volume 3 : ecological risk assessment

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-03-15

    The Sudbury soils study was comprised of 3 volumes: (1) a background, study organization and 2001 soils survey; (2) a human health risk assessment; and (3) an ecological risk assessment (ERA). This document provided details of the ERA, which was conducted to characterize the current and future risks of chemicals of concern (COC) to terrestrial and ecosystem components from Sudbury smelter particulate emissions. The extent to which COC are preventing the recovery of regionally representative terrestrial plant communities was investigated. Risks to terrestrial wildlife populations and endangered species and communities were evaluated. Samples of soil, water, sediment, plants, terrestrial invertebrates, and fish tissue were collected. Data were then analyzed by scientists and independent consultants in order to assess the impacts of arsenic, cadmium, cobalt, copper, lead, nickel and selenium. Results of the study indicated that terrestrial plant communities in the region continue to be impacted by COC in the soil, as well as by soil erosion, low nutrient levels, and a lack of soil organic matter. Direct impacts on wildlife populations were also observed. 5 refs., 7 tabs., 21 figs.

  6. Assessment of the accuracy of ABC/2 variations in traumatic epidural hematoma volume estimation: a retrospective study

    Directory of Open Access Journals (Sweden)

    Pengfei Yan

    2016-04-01

    Full Text Available Background. The traumatic epidural hematoma (tEDH volume is often used to assist in tEDH treatment planning and outcome prediction. ABC/2 is a well-accepted volume estimation method that can be used for tEDH volume estimation. Previous studies have proposed different variations of ABC/2; however, it is unclear which variation will provide a higher accuracy. Given the promising clinical contribution of accurate tEDH volume estimations, we sought to assess the accuracy of several ABC/2 variations in tEDH volume estimation. Methods. The study group comprised 53 patients with tEDH who had undergone non-contrast head computed tomography scans. For each patient, the tEDH volume was automatically estimated by eight ABC/2 variations (four traditional and four newly derived with an in-house program, and results were compared to those from manual planimetry. Linear regression, the closest value, percentage deviation, and Bland-Altman plot were adopted to comprehensively assess accuracy. Results. Among all ABC/2 variations assessed, the traditional variations y = 0.5 × A1B1C1 (or A2B2C1 and the newly derived variations y = 0.65 × A1B1C1 (or A2B2C1 achieved higher accuracy than the other variations. No significant differences were observed between the estimated volume values generated by these variations and those of planimetry (p > 0.05. Comparatively, the former performed better than the latter in general, with smaller mean percentage deviations (7.28 ± 5.90% and 6.42 ± 5.74% versus 19.12 ± 6.33% and 21.28 ± 6.80%, respectively and more values closest to planimetry (18/53 and 18/53 versus 2/53 and 0/53, respectively. Besides, deviations of most cases in the former fell within the range of 20% (90.57% and 96.23, respectively. Discussion. In the current study, we adopted an automatic approach to assess the accuracy of several ABC/2 variations for tEDH volume estimation. Our initial results showed that the variations y = 0.5 × A1B1C1 (or A2B2C1

  7. Nuclear proliferation and civilian nuclear power: report of the Nonproliferation Alternative Systems Assessment Program. Volume VII. International perspectives

    International Nuclear Information System (INIS)

    1979-12-01

    The purpose of this volume is to assess the proliferation vulnerabilities of the present deployment of civilian nuclear-power systems within the current nonproliferation regime and, in light of their prospective deployment, to consider technical and institutional measures and alternatives which may contribute to an improved regime in which nuclear power could play a significant part. An assessment of these measures must include consideration of their nonproliferation effectiveness as well as their bearing upon energy security, and their operational, economic, and political implications. The nature of these considerations can provide some measure of their likely acceptability to various nations. While any final assessment of such measures and alternatives would have to examine the circumstances particular to each nation, it is hoped that the more generic assessments conducted here will be useful in suggesting guidelines for developing an improved nonproliferation regime which also helps to meet nuclear-energy needs. One chapter outlines the existing nonproliferation regime, including the Treaty for the Non-Proliferation of Nuclear Weapons (NPT), International Atomic Energy Agency (IAEA) safeguards, bilateral and multilateral requirements for agreements of cooperation and transfers of technology, and existing provisons for sanctions for violation of nonproliferation commitments. The chapter then proceeds to an assessment of various alternatives for providing assurance of fuel supply in light of this current regime. Another chapter examines a set of technical and institutional measures and alternatives for various components of once-through and closed fuel cycles. The components of the once-through fuel cycle assessed are enrichment services and spent-fuel management; the components of closed fuel cycles assessed are reprocessing and plutonium management and fast-breeder reactor (FBR) deployment

  8. Safety assessment methodologies for near surface disposal facilities. Results of a co-ordinated research project (ISAM). Volume 1: Review and enhancement of safety assessment approaches and tools. Volume 2: Test cases

    International Nuclear Information System (INIS)

    2004-07-01

    the Safety Guide on 'Safety Assessment for Near Surface Disposal of Radioactive Waste' (Safety Standards Series No. WS-G- 1.1). The report of this CRP is presented in two volumes; Volume 1 contains a summary and a complete description of the ISAM project methodology and Volume 2 presents the application of the methodology to three hypothetical test cases

  9. Health technology assessment: research trends and future priorities in Europe.

    Science.gov (United States)

    Nielsen, Camilla Palmhøj; Funch, Tina Maria; Kristensen, Finn Børlum

    2011-07-01

    To provide an overview of health services research related to health technology assessment (HTA) and to identify research priorities from a European perspective. Several methods were used: systematic review of articles indexed with the MeSH term 'technology assessment' in PubMed from February 1999-2009; online survey among experts; and conference workshop discussions. Research activity in HTA varies considerably across Europe. The research was categorised into six areas: (1) the breadth of analysis in HTA (such as economic, organizational and social aspects); (2) HTA products developed to meet the needs of policy-makers (such as horizon scanning, mini-HTA, and core HTA); (3) handling life-cycle perspectives in relation to technologies; (4) topics that challenge existing methods and for which HTA should be developed to address the themes more comprehensively (such as public health interventions and organizational interventions); (5) development of HTA capacity and programmes; and (6) links between policy and HTA. An online survey showed that the three areas that were given priority were the relationship between HTA and policy-making (71%), the impact of HTA (62%) and incorporating patient aspects in HTA (50%). Policy-makers highlighted HTA and innovation processes as their main research priority (42%). Areas that the systematic review identified as future priorities include issues within the six existing research areas such as disinvestment, developing evidence for new technologies, assessing the wider effects of technology use, and determining how HTA affects decision-making. In addition, relative effectiveness and individualized treatments are areas of growing interest. The research priorities identified are important for obtaining high quality and cost-effective health care in Europe. Managing the introduction, use and phasing out of technologies challenges health services throughout Europe, and these processes need to be improved to successfully manage future

  10. Development and assessment of closure technology for liquid-waste disposal sites

    International Nuclear Information System (INIS)

    Phillips, S.J.; Relyea, J.F.; Seitz, R.R.; Cammann, J.W.

    1990-01-01

    Discharge of low-level liquid wastes into soils was practiced previously at the Hanford Site. Technologies for long-term confinement of subsurface contaminants are needed. Additionally, methods are needed to assess the effectiveness of confinement technologies in remediating potentially diverse environmental conditions. Recently developed site remediation systems and assessment methods for in situ stabilization and isolation of radioactive and other contaminants within and below low-level liquid-waste disposal structures are summarized

  11. Study design for concurrent development, assessment, and implementation of new diagnostic imaging technology

    NARCIS (Netherlands)

    M.G.M. Hunink (Myriam); G.P. Krestin (Gabriel)

    2002-01-01

    textabstractWith current constraints on health care resources and emphasis on value for money, new diagnostic imaging technologies must be assessed and their value demonstrated. The state of the art in the field of diagnostic imaging technology assessment advocates a hierarchical

  12. Technology and Economic Assessment of Innovative Field Drainage Technologies in Denmark

    DEFF Research Database (Denmark)

    Gachango, Florence Gathoni

    Intensive agricultural production in most parts of the world especially in the more developed countries continues to mount pressure on water resources thereby threatening the quality of life in the aquatic ecosystems. With stringent standards such as those stipulated in the European Union Water...... Framework Directive (EU WFD), introduced to address the water quality problem the situation calls for solutions that would reconcile these two conflicting issues. “End-of-pipe” filter technologies that would disconnect agricultural drainage pathway before it gets to the aquatic environment have been...... proposed as appropriate solutions to this problem in the Danish context. The feasibility of these technologies with regards to their cost-effectiveness in nutrient mitigation, farmers’ adoption behavior, and environmental policy implementation is assessed in this thesis. The thesis comprises of four papers...

  13. A needs assessment for mobile technology use in medical education

    OpenAIRE

    Shahrzad Vafa; Diane E. Chico

    2013-01-01

    Objectives: This study investigated how medical students perceived mobile technology as a component of their learning experience and identified barriers to the use of mobile technology in education. Methods: An anonymous survey developed by EDUCAUSE was distributed to 1000 first year medical students (M1s) at two separate medical schools during three consecutive academic years, 2010 to 2013. The 25-item questionnaire assessed student use of mobile devices, student interest in mobile technolog...

  14. Technology, safety and costs of decommissioning a reference small mixed oxide fuel fabrication plant. Volume 2. Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, C. E.; Murphy, E. S.; Schneider, K. J.

    1979-01-01

    Volume 2 contains appendixes on small MOX fuel fabrication facility description, site description, residual radionuclide inventory estimates, decommissioning, financing, radiation dose methodology, general considerations, packaging and shipping of radioactive materials, cost assessment, and safety (JRD)

  15. IMPLEMENTATION OF HEALTH TECHNOLOGY ASSESSMENT WORK IN A HOSPITAL IN KAZAKHSTAN.

    Science.gov (United States)

    Kosherbayeva, Lyazzat; Hailey, David; Kurakbaev, Kural; Tsoy, Aleksey; Zhuzzhanov, Ormanbek; Donbay, Abilay; Kumar, Ainur; Nadyrov, Kamalzhan

    2016-01-01

    The aim of this study was to implement health technology assessment (HA) in the First General City Hospital in Astana, Kazakhstan. We organized trainings to familiarize hospital staff with the purpose and details of HTA. An HTA committee was established, with representation from hospital physicians and managers, and criteria for prioritization of health technologies determined. Clinical departments of the hospital were asked to prepare applications for new technologies for their services. The HTA committee reviewed five applications and selected a technology from one of these, on single incision laparoscopic surgery (SILS), for assessment. A short HTA report on SILS was prepared, covering its safety, clinical effectiveness, and cost effectiveness. The report was used to support a request to the Department of Health for additional funding to implement this technology within the hospital. This funding was approved and SILS was established in several hospital departments. This successful initial experience with HTA has paved the way for its routine use by the hospital for informing decisions on the procurement and use of new health technologies.

  16. Shedding light on solar technologies-A techno-economic assessment and its policy implications

    International Nuclear Information System (INIS)

    Peters, Michael; Schmidt, Tobias S.; Wiederkehr, David; Schneider, Malte

    2011-01-01

    Solar power technologies will have to become a major pillar in the world's future energy system to combat climate change and resource depletion. However, it is unclear which solar technology is and will prove most viable. Therefore, a comprehensive comparative assessment of solar technologies along the key quantitative and qualitative competitiveness criteria is needed. Based on a literature review and detailed techno-economic modeling for 2010 and 2020 in five locations, we provide such an assessment for the three currently leading large-scale solar technologies. We show that today these technologies cannot yet compete with conventional forms of power generation but approach competitiveness around 2020 in favorable locations. Furthermore, from a global perspective we find that none of the solar technologies emerges as a clear winner and that cost of storing energy differs by technology and can change the order of competitiveness in some instances. Importantly, the competitiveness of the different technologies varies considerably across locations due to differences in, e.g., solar resource and discount rates. Based on this analysis, we discuss policy implications with regard to fostering the diffusion of solar technologies while increasing the efficiency of policy support through an adequate geographical allocation of solar technologies. - Highlights: → We conduct a comprehensive comparative assessment of solar technologies (CSP/PV). → While solar technologies approach competitiveness in 2020, no clear winner emerges. → Solar resource and discount rate heavily impact competitiveness of solar technologies. → Adequate geographical allocation of solar technologies increases policy efficiency. → Focus on key cost down levers and strategic co-benefits of solar technologies needed.

  17. Environmental contaminants in food. Volume II-Part B: Working papers

    International Nuclear Information System (INIS)

    1980-01-01

    This volume contains working papers written for Office of Technology Assessment (OTA) to assist in preparation of the report Environmental Contaminants in Food. The contents include: (1) Toxic substances in food information systems: design and management; (2) Assessment of carcinogenic risks from PCBs in food; (3) Economic analysis of alternative action levels in the regulation of environmental contaminants in food; (4) Analysis of foods for radioactivity; (5) Approaches to monitoring environmental contaminants in food; (6) Analytical systems for the determination of metals in food and water supplies; (7) Assessment of methods for regulating 'unavoidable' contaminants in the food supply; and (8) Consumer risk from environmental contaminants in food

  18. Novel sensing technology in fall risk assessment in older adults: a systematic review.

    Science.gov (United States)

    Sun, Ruopeng; Sosnoff, Jacob J

    2018-01-16

    Falls are a major health problem for older adults with significant physical and psychological consequences. A first step of successful fall prevention is to identify those at risk of falling. Recent advancement in sensing technology offers the possibility of objective, low-cost and easy-to-implement fall risk assessment. The objective of this systematic review is to assess the current state of sensing technology on providing objective fall risk assessment in older adults. A systematic review was conducted in accordance to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis statement (PRISMA). Twenty-two studies out of 855 articles were systematically identified and included in this review. Pertinent methodological features (sensing technique, assessment activities, outcome variables, and fall discrimination/prediction models) were extracted from each article. Four major sensing technologies (inertial sensors, video/depth camera, pressure sensing platform and laser sensing) were reported to provide accurate fall risk diagnostic in older adults. Steady state walking, static/dynamic balance, and functional mobility were used as the assessment activity. A diverse range of diagnostic accuracy across studies (47.9% - 100%) were reported, due to variation in measured kinematic/kinetic parameters and modelling techniques. A wide range of sensor technologies have been utilized in fall risk assessment in older adults. Overall, these devices have the potential to provide an accurate, inexpensive, and easy-to-implement fall risk assessment. However, the variation in measured parameters, assessment tools, sensor sites, movement tasks, and modelling techniques, precludes a firm conclusion on their ability to predict future falls. Future work is needed to determine a clinical meaningful and easy to interpret fall risk diagnosis utilizing sensing technology. Additionally, the gap between functional evaluation and user experience to technology should be addressed.

  19. Achievement report for fiscal 1976 on Sunshine Program. Technology assessment of hydrogen energy technologies III; 1976 nendo suiso energy gijutsu no technology assessment. 3

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1977-03-31

    This report contains the ultimate results of the 3-year research endeavor on 'Technology assessment of hydrogen energy technologies.' The scientists engaged in the project express their impressions at the conclusion of the research, stating: 'In the development of hydrogen energy technologies, what is the most important at the present stage is to define the formation of the energy more clearly - in what shape or at what place - so that various activities in this connection will be organized.' They say also: 'Although the type of research effort of looking into technological possibilities is quite important naturally, yet such should been carried out with a sense of purpose which is definite and concrete.' Before what are stated above may be complied with, of course, systems for development have to be arranged allowing the scientists to act in the above-suggested way. This report consists of a general discussion part and an itemized discussion part. The former summarizes the intention, aim, premise, contents, findings, opinions, etc., concerning the research work; and the latter carries a gist of the 'Hydrogen energy system concept (draft)' which constitutes the foundation on which the above-mentioned details are discussed in the former. (NEDO)

  20. Integrated assessment of bioelectricity technology options

    International Nuclear Information System (INIS)

    Thornley, Patricia; Upham, Paul; Huang, Ye; Rezvani, Sina; Brammer, John; Rogers, John

    2009-01-01

    Power generation from biomass is a sustainable energy technology which can contribute to substantial reductions in greenhouse gas emissions, but with greater potential for environmental, economic and social impacts than most other renewable energy technologies. It is important therefore in assessing bioenergy systems to take account of not only technical, but also environmental, economic and social parameters on a common basis. This work addresses the challenge of analysing, quantifying and comparing these factors for bioenergy power generation systems. A life-cycle approach is used to analyse the technical, environmental, economic and social impacts of entire bioelectricity systems, with a number of life-cycle indicators as outputs to facilitate cross-comparison. The results show that similar greenhouse gas savings are achieved with the wide variety of technologies and scales studied, but land-use efficiency of greenhouse gas savings and specific airborne emissions varied substantially. Also, while specific investment costs and electricity costs vary substantially from one system to another the number of jobs created per unit of electricity delivered remains roughly constant. Recorded views of stakeholders illustrate that diverging priorities exist for different stakeholder groups and this will influence appropriate choice of bioenergy systems for different applications

  1. Summary of 2017 NASA Workshop on Assessment of Advanced Battery Technologies for Aerospace Applications

    Science.gov (United States)

    Misra, Ajay

    2018-01-01

    A workshop on assessment of battery technologies for future aerospace applications was held in Cleveland, OH on August 16-17. The focus of the workshop, hosted by NASA GRC, was to assess (1) the battery needs for future aerospace missions, (2) the state of battery technology and projected technology advances, and (3) the need for additional investments for future aerospace missions. The workshop had 109 attendees that included internationally recognized technology leaders from academia and national laboratories, high level executives from government and industry, small businesses, and startup companies. A significant portion of the workshop was focused on batteries for electrified aircraft. The presentation will summarize the finding on the state of battery technologies for electrified aircraft and will include assessment of current state of battery technology, gaps in battery technology for application in electrified aircraft, and recommended technology development options for meeting near-term and long-term needs of electrified aircraft.

  2. Cape Canaveral Air Force Station integrated resource assessment. Volume 3, Resource assessment

    Energy Technology Data Exchange (ETDEWEB)

    Sandusky, W.F.; Eichman, C.J.; King, D.A.; McMordie, K.L.; Parker, S.A.; Shankle, S.A.; Wahlstrom, R.R.

    1994-03-01

    The U.S. Air Force (USAF) has tasked the Pacific Northwest Laboratory (PNL) in support of the U.S. Department of Energy (DOE) Federal Energy Management Program (FEMP), to identify, evaluate, and assist in acquiring all cost-effective energy projects at Cape Canaveral Air Force Station (AFS). Projects considered can be either in the form of energy management or energy conservation. The overall efforts of this task are based on a model program PNL is designing to support energy-use decisions in the federal sector. This report provides the results of the fossil fuel and electric energy resource opportunity (ERO) assessments performed by PNL at Cape Canaveral AFS, which is located approximately 10 miles north of Cocoa Beach, Florida. It is a companion report to Volume 1: Executive Summary and Volume 2: Baseline Detail. The results of the analyses of EROs are presented in 11 common energy end-use categories (e.g., boilers and furnaces, service hot water, and building lighting). A narrative description of each ERO is provided, including information on the installed cost, energy and dollar savings, impacts on operations and maintenance (O&M), and, when applicable, a discussion of energy supply and demand, energy security, and environmental issues. Descriptions of the evaluation methodologies and technical and cost assumptions are also provided for each ERO. Summary tables present the cost- effectiveness of energy end-use equipment before and after the implementation of each ERO and present the results of the life-cycle cost (LCC) analysis, indicating the net present value (NPV) and savings-to-investment ratio (SIR) of each ERO.

  3. Probabilistic accident consequence uncertainty analysis: Food chain uncertainty assessment. Volume 2: Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Brown, J. [National Radiological Protection Board (United Kingdom); Goossens, L.H.J.; Kraan, B.C.P. [Delft Univ. of Technology (Netherlands)] [and others

    1997-06-01

    This volume is the second of a two-volume document that summarizes a joint project by the US Nuclear Regulatory and the Commission of European Communities to assess uncertainties in the MACCS and COSYMA probabilistic accident consequence codes. These codes were developed primarily for estimating the risks presented by nuclear reactors based on postulated frequencies and magnitudes of potential accidents. This two-volume report, which examines mechanisms and uncertainties of transfer through the food chain, is the first in a series of five such reports. A panel of sixteen experts was formed to compile credible and traceable uncertainty distributions for food chain transfer that affect calculations of offsite radiological consequences. Seven of the experts reported on transfer into the food chain through soil and plants, nine reported on transfer via food products from animals, and two reported on both. The expert judgment elicitation procedure and its outcomes are described in these volumes. This volume contains seven appendices. Appendix A presents a brief discussion of the MAACS and COSYMA model codes. Appendix B is the structure document and elicitation questionnaire for the expert panel on soils and plants. Appendix C presents the rationales and responses of each of the members of the soils and plants expert panel. Appendix D is the structure document and elicitation questionnaire for the expert panel on animal transfer. The rationales and responses of each of the experts on animal transfer are given in Appendix E. Brief biographies of the food chain expert panel members are provided in Appendix F. Aggregated results of expert responses are presented in graph format in Appendix G.

  4. Probabilistic accident consequence uncertainty analysis: Food chain uncertainty assessment. Volume 2: Appendices

    International Nuclear Information System (INIS)

    Brown, J.; Goossens, L.H.J.; Kraan, B.C.P.

    1997-06-01

    This volume is the second of a two-volume document that summarizes a joint project by the US Nuclear Regulatory and the Commission of European Communities to assess uncertainties in the MACCS and COSYMA probabilistic accident consequence codes. These codes were developed primarily for estimating the risks presented by nuclear reactors based on postulated frequencies and magnitudes of potential accidents. This two-volume report, which examines mechanisms and uncertainties of transfer through the food chain, is the first in a series of five such reports. A panel of sixteen experts was formed to compile credible and traceable uncertainty distributions for food chain transfer that affect calculations of offsite radiological consequences. Seven of the experts reported on transfer into the food chain through soil and plants, nine reported on transfer via food products from animals, and two reported on both. The expert judgment elicitation procedure and its outcomes are described in these volumes. This volume contains seven appendices. Appendix A presents a brief discussion of the MAACS and COSYMA model codes. Appendix B is the structure document and elicitation questionnaire for the expert panel on soils and plants. Appendix C presents the rationales and responses of each of the members of the soils and plants expert panel. Appendix D is the structure document and elicitation questionnaire for the expert panel on animal transfer. The rationales and responses of each of the experts on animal transfer are given in Appendix E. Brief biographies of the food chain expert panel members are provided in Appendix F. Aggregated results of expert responses are presented in graph format in Appendix G

  5. Risk analysis and technology assessment in support of technology development: Putting responsible innovation in practice in a case study for nanotechnology.

    Science.gov (United States)

    van Wezel, Annemarie P; van Lente, Harro; van de Sandt, Johannes Jm; Bouwmeester, Hans; Vandeberg, Rens Lj; Sips, Adrienne Jam

    2018-01-01

    Governments invest in "key enabling technologies," such as nanotechnology, to solve societal challenges and boost the economy. At the same time, governmental agencies demand risk reduction to prohibit any often unknown adverse effects, and industrial parties demand smart approaches to reduce uncertainties. Responsible research and innovation (RRI) is therefore a central theme in policy making. Risk analysis and technology assessment, together referred to as "RATA," can provide a basis to assess human, environmental, and societal risks of new technological developments during the various stages of technological development. This assessment can help both governmental authorities and innovative industry to move forward in a sustainable manner. Here we describe the developed procedures and products and our experiences to bring RATA in practice within a large Dutch nanotechnology consortium. This is an example of how to put responsible innovation in practice as an integrated part of a research program, how to increase awareness of RATA, and how to help technology developers perform and use RATA. Integr Environ Assess Manag 2018;14:9-16. © 2017 The Authors. Integrated Environmental Assessment and Management published by Wiley Periodicals, Inc. on behalf of Society of Environmental Toxicology & Chemistry (SETAC). © 2017 The Authors. Integrated Environmental Assessment and Management published by Wiley Periodicals, Inc. on behalf of Society of Environmental Toxicology & Chemistry (SETAC).

  6. Vandenberg Air Force Base integrated resource assessment. Volume 3, Resource assessment

    Energy Technology Data Exchange (ETDEWEB)

    Daellenbach, K.K.; Dagle, J.E.; Dittmer, A.L.; Elliott, D.B.; Halverson, M.A.; Hickman, B.J.; Parker, G.B.; Richman, E.E.; Shankle, S.A.

    1993-06-01

    The US Air Force Space Command (SPACECOM) has tasked the Pacific Northwest Laboratory (PNL), as the lead laboratory supporting the US Department of Energy (DOE) Federal Energy Management Program (FEMP), to identify, evaluate, and assist in acquiring all cost-effective energy projects at Vandenberg Air Force Base (VAFB). This is part of a model program that PNL is designing to support energy-use decisions in the federal sector. This report provides the results of the fossil fuel and electric energy resource opportunity (ERO) assessments performed by PNL at the SPACECOM VAFB facility located approximately 50 miles northwest of Santa Barbara, California. It is a companion report to Volume 1, Executive Summary, and Volume 2, Baseline Detail. The results of the analysis of EROs are presented in ten common energy end-use categories (e.g., boilers and furnaces, service hot water, and building lighting). In addition, a case study of process loads at Space Launch Complex-4 (SLC-4) is included. A narrative description of each ERO is provided, including information on the installed cost, energy and dollar savings; impacts on operation and maintenance (O and M); and, when applicable, a discussion of energy supply and demand, energy security, and environmental issues. A description of the evaluation methodologies and technical and cost assumptions is also provided for each ERO. Summary tables present the cost-effectiveness of energy end-use equipment before and after the implementation of each ERO and present the results of the life-cycle cost (LCC) analysis indicating the net present value (NPV) and value index (VI) of each ERO. Finally, an appendix includes a summary of an economic analysis case study of the South Vandenberg Power Plant (SVPP) operating scenarios.

  7. Developing an Instrument for Assessing Students' Concepts of the Nature of Technology

    Science.gov (United States)

    Liou, Pey-Yan

    2015-01-01

    Background: The nature of technology has been rarely discussed despite the fact that technology plays an essential role in modern society. It is important to discuss students' concepts of the nature of technology, and further to advance their technological literacy and adaptation to modern society. There is a need to assess high school students'…

  8. 1988 DOE model conference proceedings: Volume 5

    Energy Technology Data Exchange (ETDEWEB)

    1988-01-01

    These Proceedings of the October 3--7, 1988 DOE Model Conference are a compilation of the papers that were presented in the technical or poster sessions at the conference papers and posters not submitted for publication are not included in the Proceedings. The Table of Contents lists the titles of papers as well as the names of the presenters. These individuals are not, in all cases, the primary authors of the papers published. The actual title pages, appearing later with the papers, show the primary author(s) and all co-authors. The papers in all three volumes of the Proceedings appear as they were originally submitted for publication and have not been edited or changed in any way. Topics discussed in Volume 5 include environmental assessments and program strategies, waste treatment technologies, and regulations and compliance studies.

  9. 1988 DOE model conference proceedings: Volume 5

    International Nuclear Information System (INIS)

    1988-01-01

    These Proceedings of the October 3--7, 1988 DOE Model Conference are a compilation of the papers that were presented in the technical or poster sessions at the conference papers and posters not submitted for publication are not included in the Proceedings. The Table of Contents lists the titles of papers as well as the names of the presenters. These individuals are not, in all cases, the primary authors of the papers published. The actual title pages, appearing later with the papers, show the primary author(s) and all co-authors. The papers in all three volumes of the Proceedings appear as they were originally submitted for publication and have not been edited or changed in any way. Topics discussed in Volume 5 include environmental assessments and program strategies, waste treatment technologies, and regulations and compliance studies

  10. Radiation detection technology assessment program (RADTAP)

    International Nuclear Information System (INIS)

    Smith, D.E.

    1998-01-01

    The U.S. Customs Service and the U.S. Department of Energy (DOE) conducted a technical and operational assessment of gamma ray radiation detection equipment during the period May 5-16, 1997 at a testing facility in North Carolina. The effort was entitled, ''Radiation Detection Technology Assessment Program (RADTAP)'', and was conducted for the purpose of assessing the applicability, sensitivity and robustness of a diverse suite of gamma ray detection and identification equipment for possible use by Customs and other law enforcement agencies. Thirteen companies entered 25 instruments into the assessment program. All detection equipment entered had to exhibit a minimum sensitivity of 20 micro-R per hour (background included) from a Cesium-137 point source. Isotope identifying spectrometers entered were man portable and operable at room temperature with read-out that could be interpreted by non-technical personnel. Radioactive sources used in the assessment included special nuclear material, industrial and health isotopes. Evaluators included Customs inspectors and technical experts from DOE and Customs. No conclusions or recommendations were issued based on the quantitative and qualitative test results, however, the results of the program provided law enforcement agencies with the necessary data to select equipment that best meets their operational needs and budgets. (author)

  11. Assessment of material and technical resources of crop production technologies

    Directory of Open Access Journals (Sweden)

    V. M. Beylis

    2017-01-01

    Full Text Available The author explains the general principles of influence of the material and technical resources (MTR on performance and efficiency of the main technological operations in crop production. Various technologies from the point of view of MTR expenses were estimated. The general tendencies in development of crop production technologies were revealed. The distribution of costs of materials and equipment to perform a variety of agricultural activities was determined. Cost indicators should be a guide in the search of innovative technological processes and working elements of agricultural machins. The greatest values of expenses of work, fuel, metal, and also, money where found. The concepts allowing to provide costs production reduction were formulated. To achieve the maximum productivity with the minimum expenses, the perspective calculations shoul be based on «progressive» agrotechnologies. When determining progressive agrotechnology it is necessary on reasonable grounds to approach indicators of crop productivity in various agrozones and regions of the country. For an assessment of efficiency of MTR by crop production and ensuring decrease in resource intensity of agricultural products by search and use of essentially new technologies for energy saving when performing agricultural operations, an integrated percentage indicator of comparison of progressive technologies with the applied ones was developed. MTR at application of new progressive crop production technologies by integrated percentage index were estimated. This indicator can be used for definition of efficiency of MTR. Application of the offered technique will promote an effective assessment of MTR, decrease in resource intensity by search and developments of essentially new technologies of performance of operations in crop production.

  12. Low-level radioactive waste from commercial nuclear reactors. Volume 3. Bibliographic abstracts of significant source references. Part 2. Bibliography for treatment, storage, disposal and transportation regulatory constraints

    Energy Technology Data Exchange (ETDEWEB)

    Jolley, R.L.; Rodgers, B.R.

    1986-05-01

    The overall task of this program was to provide an assessment of currently available technology for treating commercial low-level radioactive waste (LLRW), to initiate development of a methodology for choosing one technology for a given application, and to identify research needed to improve current treatment techniques and decision methodology. The resulting report is issued in four volumes. Volume 3 of this series is a collection of abstracts of most of the reference documents used for this study. Because of the large volume of literature, the abstracts have been printed in two separate parts. Federal, state, and local regulations affect the decision process for selecting technology applications. Regulations may favor a particular technology and may prevent application of others. Volume 3, part 2 presents abstracts of the regulatory constraint documents that relate to all phases of LLRW management (e.g., treatment, packaging, storage, transportation, and disposal).

  13. A Self-Assessment Framework for Inclusive Schools Supporting Assistive Technology Users.

    Science.gov (United States)

    Hoogerwerf, Evert-Jan; Solander-Gross, Andrea; Mavrou, Katerina; Traina, Ivan; Hersh, Marion

    2017-01-01

    In order to support schools to assess their performance in supporting children with disabilities in their ICT and ICT-AT needs, a self-assessment framework was developed by a task force of partners and associate partners of the ENTELIS project. The self-assessment tool aims to help educational establishments that welcome learners with disabilities to assess their current outcomes and to plan improvements in supporting these students in increasing digital literacy and developing digital skills. This includes the use of mainstream Information and Communication Technology (ICT) and specially designed digital Assistive Technologies (ICT-AT). This can only successfully happen if schools fully embrace an inclusive approach to education. In this paper the authors describe the development of the framework and the further steps for its use.

  14. Mapping of health technology assessment in selected countries

    NARCIS (Netherlands)

    Oortwijn, W.; Broos, P.; Vondeling, Hindrik; Banta, D.; Todorova, L.

    2013-01-01

    Objectives: The aim of this study was to develop and apply an instrument to map the level of health technology assessment (HTA) development at country level in selected countries. We examined middle-income countries (Argentina, Brazil, India, Indonesia, Malaysia, Mexico, and Russia) and countries

  15. Assessment of left atrial volume and function: a comparative study between echocardiography, magnetic resonance imaging and multi slice computed tomography.

    Science.gov (United States)

    Kühl, J Tobias; Lønborg, Jacob; Fuchs, Andreas; Andersen, Mads J; Vejlstrup, Niels; Kelbæk, Henning; Engstrøm, Thomas; Møller, Jacob E; Kofoed, Klaus F

    2012-06-01

    Measurement of left atrial (LA) maximal volume (LA(max)) using two-dimensional transthoracic echocardiography (TTE) provides prognostic information in several cardiac diseases. However, the relationship between LA(max) and LA function is poorly understood and TTE is less well suited for measuring dynamic LA volume changes. Conversely, cardiac magnetic resonance imaging (CMR) and multi-slice computed tomography (MSCT) appears more appropriate for such measures. We sought to determine the relationship between LA size assessed with TTE and LA size and function assessed with CMR and MSCT. Fifty-four patients were examined 3 months post myocardial infarction with echocardiography, CMR and MSCT. Left atrial volumes and LA reservoir function were assessed by TTE. LA time-volume curves were determined and LA reservoir function (cyclic change and fractional change), passive emptying function (reservoir volume) and pump function (left atrial ejection fraction-LAEF) were derived using CMR and MSCT. Left atrial fractional change and left atrial ejection fraction (LAEF) determined with CMR and MSCT were unrelated to LA(max) enlargement by echocardiography (P = NS). There was an overall good agreement between CMR and MSCT, with a small to moderate bias in LA(max) (4.9 ± 10.4 ml), CC (3.1 ± 9.1 ml) and reservoir volume (3.4 ± 9.1 ml). TTE underestimates LA(max) with up to 32% compared with CMR and MSCT (P fractional change and LAEF is not significantly related to LA(max) measured by TTE. TTE systematically underestimated LA volumes, whereas there are good agreements between MSCT and CMR for volumetric and functional properties.

  16. Energy and the environment: Technology assessment and policy options

    International Nuclear Information System (INIS)

    Silveira, M.P.W.

    1990-01-01

    While the energy crisis of the 1970s stimulated technological innovation in developed countries, it often had the opposite effect in the third world. However, developing countries can be considered to have two types of energy systems: ''connected'' and ''disconnected''. The connected system is affected by changes in the price of commercial energy, but the disconnected system is usually rural and remote. Commercial forms of energy may be needed in the disconnected system, but they are largely unavailable. In some of the developing countries, new energy technologies have therefore been developed which adapt traditional technologies still existing in the disconnected sector. In this article some of the work of the United National Centre for Science and Technology for Development is described. Through its ATAS (Advance Technology Alert System) programme, international and regional workshops are held to discuss policy questions arising in regard to new technologies and developments. Workshops have been held in Moscow on new energy technologies in the industry subsystem (connected), in Guatemala City on new energy technologies and the disconnected system, and in Ottawa on new energy technologies, transportation and development. Initial assessments made by or through these workshops are outlined here. A fourth workshop will be held in June 1990 in Saarbrucken on energy technologies and climate change. (author). 3 figs

  17. Exploratory assessment of left ventricular strain–volume loops in severe aortic valve diseases

    Science.gov (United States)

    Hulshof, Hugo G.; van Dijk, Arie P.; George, Keith P.; Hopman, Maria T. E.; Thijssen, Dick H. J.

    2017-01-01

    Key points Severe aortic valve diseases are common cardiac abnormalities that are associated with poor long‐term survival.Before any reduction in left ventricular (LV) function, the left ventricle undergoes structural remodelling under the influence of changing haemodynamic conditions.In this study, we combined temporal changes in LV structure (volume) with alterations in LV functional characteristics (strain, ԑ) into a ԑ–volume loop, in order to provide novel insight into the haemodynamic cardiac consequences of aortic valve diseases in those with preserved LV ejection fraction.We showed that our novel ԑ–volume loop and the specific loop characteristics provide additional insight into the functional and mechanical haemodynamic consequences of severe aortic valve diseases (with preserved LV ejection fraction).Finally, we showed that the ԑ–volume loop characteristics provide discriminative capacity compared with conventional measures of LV function. Abstract The purpose of this study was to examine left ventricular (LV) strain (ԑ)–volume loops to provide novel insight into the haemodynamic cardiac consequences of aortic valve stenosis (AS) and aortic valve regurgitation (AR). Twenty‐seven participants were retrospectively recruited: AR (n = 7), AS (n = 10) and control subjects (n = 10). Standard transthoracic echocardiography was used to obtain apical four‐chamber images to construct ԑ–volume relationships, which were assessed using the following parameters: early systolic ԑ (ԑ_ES); slope of ԑ–volume relationship during systole (Sslope); end‐systolic peak ԑ (peak ԑ); and diastolic uncoupling (systolic ԑ–diastolic ԑ at same volume) during early diastole (UNCOUP_ED) and late diastole (UNCOUP_LD). Receiver operating characteristic curves were used to determine the ability to detect impaired LV function. Although LV ejection fraction was comparable between groups, longitudinal peak ԑ was reduced compared with control subjects

  18. Exploratory assessment of left ventricular strain-volume loops in severe aortic valve diseases.

    Science.gov (United States)

    Hulshof, Hugo G; van Dijk, Arie P; George, Keith P; Hopman, Maria T E; Thijssen, Dick H J; Oxborough, David L

    2017-06-15

    Severe aortic valve diseases are common cardiac abnormalities that are associated with poor long-term survival. Before any reduction in left ventricular (LV) function, the left ventricle undergoes structural remodelling under the influence of changing haemodynamic conditions. In this study, we combined temporal changes in LV structure (volume) with alterations in LV functional characteristics (strain, ԑ) into a ԑ-volume loop, in order to provide novel insight into the haemodynamic cardiac consequences of aortic valve diseases in those with preserved LV ejection fraction. We showed that our novel ԑ-volume loop and the specific loop characteristics provide additional insight into the functional and mechanical haemodynamic consequences of severe aortic valve diseases (with preserved LV ejection fraction). Finally, we showed that the ԑ-volume loop characteristics provide discriminative capacity compared with conventional measures of LV function. The purpose of this study was to examine left ventricular (LV) strain (ԑ)-volume loops to provide novel insight into the haemodynamic cardiac consequences of aortic valve stenosis (AS) and aortic valve regurgitation (AR). Twenty-seven participants were retrospectively recruited: AR (n = 7), AS (n = 10) and control subjects (n = 10). Standard transthoracic echocardiography was used to obtain apical four-chamber images to construct ԑ-volume relationships, which were assessed using the following parameters: early systolic ԑ (ԑ_ES); slope of ԑ-volume relationship during systole (Sslope); end-systolic peak ԑ (peak ԑ); and diastolic uncoupling (systolic ԑ-diastolic ԑ at same volume) during early diastole (UNCOUP_ED) and late diastole (UNCOUP_LD). Receiver operating characteristic curves were used to determine the ability to detect impaired LV function. Although LV ejection fraction was comparable between groups, longitudinal peak ԑ was reduced compared with control subjects. In contrast, ԑ_ES and Sslope were

  19. Assessing intravascular volume by difference in pulse pressure in pigs submitted to graded hemorrhage.

    Science.gov (United States)

    Pestel, Gunther J; Hiltebrand, Luzius B; Fukui, Kimiko; Cohen, Delphine; Hager, Helmut; Kurz, Andrea M

    2006-10-01

    We assessed changes in intravascular volume monitored by difference in pulse pressure (dPP%) after stepwise hemorrhage in an experimental pig model. Six pigs (23-25 kg) were anesthetized (isoflurane 1.5 vol%) and mechanically ventilated to keep end-tidal CO2 (etCO2) at 35 mmHg. A PA-catheter and an arterial catheter were placed via femoral access. During and after surgery, animals received lactated Ringer's solution as long as they were considered volume responders (dPP>13%). Then animals were allowed to stabilize from the induction of anesthesia and insertion of catheters for 30 min. After stabilization, baseline measurements were taken. Five percent of blood volume was withdrawn, followed by another 5%, and then in 10%-increments until death from exsanguination occurred. After withdrawal of 5% of blood volume, all pigs were considered volume responders (dPP>13%); dPP rose significantly from 6.1+/-3.3% to 19.4+/-4.2%. The regression analysis of stepwise hemorrhage revealed a linear relation between blood loss (hemorrhage in %) and dPP (y=0.99*x+14; R2=0.7764; P<.0001). In addition, dPP was the only parameter that changed significantly between baseline and a blood loss of 5% (P<0.01), whereas cardiac output, stroke volume, heart rate, MAP, central venous pressure, pulmonary artery occlusion pressure, and systemic vascular resistance, respectively, remained unchanged. We conclude that in an experimental hypovolemic pig model, dPP correlates well with blood loss.

  20. Electronic Engineering Technology Program Exit Examination as an ABET and Self-Assessment Tool

    Science.gov (United States)

    Thomas, Gary; Darayan, Shahryar

    2018-01-01

    Every engineering, computing, and engineering technology program accredited by the Accreditation Board for Engineering and Technology (ABET) has formulated many and varied self-assessment methods. Methods used to assess a program for ABET accreditation and continuous improvement are for keeping programs current with academic and industrial…

  1. A State-of-the-Art Report on Technologies of Volume Reduction and Self-Disposal for Large Metal Wastes including the Steam Generator of Nuclear Power Plants

    International Nuclear Information System (INIS)

    Lee, Kune Woo; Choi, W. K.; Kim, G. Y.

    2009-06-01

    This report focuses on technologies of volume reduction and self-disposal for large metal wastes including the steam generator of nuclear power plants. This report consists of the cases of treatments and foreign and domestic technologies for steam generator replacement

  2. Sustainability Assessment of Electricity Generation Technologies in Egypt Using Multi-Criteria Decision Analysis

    Directory of Open Access Journals (Sweden)

    Mostafa Shaaban

    2018-05-01

    Full Text Available Future electricity planning necessitates a thorough multi-faceted analysis of the available technologies in order to secure the energy supply for coming generations. To cope with worldwide concerns over sustainable development and meet the growing demands of electricity we assess the future potential technologies in Egypt through covering their technical, economic, environmental and social aspects. In this study we fill the gap of a lacking sustainability assessment of energy systems in Egypt where most of the studies focus mainly on the economic and technical aspects of planning future installation of power plants in Egypt. Furthermore, we include the stakeholder preferences of the indicators in the energy sector into our assessment. Moreover, we perform a sensitivity analysis through single dimension assessment scenarios of the technologies as well as a sustainable scenario with equal preferences of all dimensions of the sustainability. We employ two multi-criteria decision analysis (MCDA methodologies: the analytical hierarchy process for weighing the assessment criteria, and the weighted sum method for generating a general integrated sustainability index for each technology. The study investigates seven technologies: coal, natural gas, wind, concentrated solar power, photovoltaics, biomass and nuclear. The results reveal a perfect matching between the ranking of the technologies by the stakeholders and the sustainable scenario showing the highest ranking for natural gas and the lowest for nuclear and coal. There is a strong potential for renewable energy technologies to invade the electricity market in Egypt where they achieve the second ranking after natural gas. The Monte-Carlo approach gives photovoltaics a higher ranking over concentrated solar power as compared to the sample data ranking. The study concludes the importance of a multi-dimensional evaluation of the technologies while considering the preferences of the stakeholders in

  3. HVDC power transmission technology assessment

    Energy Technology Data Exchange (ETDEWEB)

    Hauth, R.L.; Tatro, P.J.; Railing, B.D. [New England Power Service Co., Westborough, MA (United States); Johnson, B.K.; Stewart, J.R. [Power Technologies, Inc., Schenectady, NY (United States); Fink, J.L.

    1997-04-01

    The purpose of this study was to develop an assessment of the national utility system`s needs for electric transmission during the period 1995-2020 that could be met by future reduced-cost HVDC systems. The assessment was to include an economic evaluation of HVDC as a means for meeting those needs as well as a comparison with competing technologies such as ac transmission with and without Flexible AC Transmission System (FACTS) controllers. The role of force commutated dc converters was to be assumed where appropriate. The assessment begins by identifying the general needs for transmission in the U.S. in the context of a future deregulated power industry. The possible roles for direct current transmission are then postulated in terms of representative scenarios. A few of the scenarios are illustrated with the help of actual U.S. system examples. non-traditional applications as well as traditional applications such as long lines and asynchronous interconnections are discussed. The classical ``break-even distance`` concept for comparing HVDC and ac lines is used to assess the selected scenarios. The impact of reduced-cost converters is reflected in terms of the break-even distance. This report presents a comprehensive review of the functional benefits of HVDC transmission and updated cost data for both ac and dc system components. It also provides some provocative thoughts on how direct current transmission might be applied to better utilize and expand our nation`s increasingly stressed transmission assets.

  4. Priority survey between indicators and analytic hierarchy process analysis for green chemistry technology assessment.

    Science.gov (United States)

    Kim, Sungjune; Hong, Seokpyo; Ahn, Kilsoo; Gong, Sungyong

    2015-01-01

    This study presents the indicators and proxy variables for the quantitative assessment of green chemistry technologies and evaluates the relative importance of each assessment element by consulting experts from the fields of ecology, chemistry, safety, and public health. The results collected were subjected to an analytic hierarchy process to obtain the weights of the indicators and the proxy variables. These weights may prove useful in avoiding having to resort to qualitative means in absence of weights between indicators when integrating the results of quantitative assessment by indicator. This study points to the limitations of current quantitative assessment techniques for green chemistry technologies and seeks to present the future direction for quantitative assessment of green chemistry technologies.

  5. A DECADE OF HEALTH TECHNOLOGY ASSESSMENT IN POLAND

    NARCIS (Netherlands)

    Lipska, Iga; McAuslane, James Neil; Leufkens, Bert; Hövels, Anke

    OBJECTIVES: The objective of this study is to illustrate and provide a better understanding of the role of health technology assessment (HTA) processes in decision making for drug reimbursement in Poland and how this approach could be considered by other countries of limited resources. METHODS: We

  6. Wearable technology for spine movement assessment: A systematic review.

    Science.gov (United States)

    Papi, Enrica; Koh, Woon Senn; McGregor, Alison H

    2017-11-07

    Continuous monitoring of spine movement function could enhance our understanding of low back pain development. Wearable technologies have gained popularity as promising alternative to laboratory systems in allowing ambulatory movement analysis. This paper aims to review the state of art of current use of wearable technology to assess spine kinematics and kinetics. Four electronic databases and reference lists of relevant articles were searched to find studies employing wearable technologies to assess the spine in adults performing dynamic movements. Two reviewers independently identified relevant papers. Customised data extraction and quality appraisal form were developed to extrapolate key details and identify risk of biases of each study. Twenty-two articles were retrieved that met the inclusion criteria: 12 were deemed of medium quality (score 33.4-66.7%), and 10 of high quality (score >66.8%). The majority of articles (19/22) reported validation type studies. Only 6 reported data collection in real-life environments. Multiple sensors type were used: electrogoniometers (3/22), strain gauges based sensors (3/22), textile piezoresistive sensor (1/22) and accelerometers often used with gyroscopes and magnetometers (15/22). Two sensors units were mainly used and placing was commonly reported on the spine lumbar and sacral regions. The sensors were often wired to data transmitter/logger resulting in cumbersome systems. Outcomes were mostly reported relative to the lumbar segment and in the sagittal plane, including angles, range of motion, angular velocity, joint moments and forces. This review demonstrates the applicability of wearable technology to assess the spine, although this technique is still at an early stage of development. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  7. Demonstration of Airborne Wide Area Assessment Technologies at the Toussaint River, Ohio

    National Research Council Canada - National Science Library

    Foley, Jack; Wright, David

    2007-01-01

    ...) technology, a wide area assessment technology, to assist in the characterization of the shore and shallow areas in and around the Toussaint River relative to munitions contamination from historical...

  8. The potential impact of computer-aided assessment technology in ...

    African Journals Online (AJOL)

    The potential impact of computer-aided assessment technology in higher education. ... Further more 'Increased number of students in Higher Education and the ... benefits, limitations, impacts on student learning and strategies for developing ...

  9. An assessment of advanced displays and controls technology applicable to future space transportation systems

    Science.gov (United States)

    Hatfield, Jack J.; Villarreal, Diana

    1990-01-01

    The topic of advanced display and control technology is addressed along with the major objectives of this technology, the current state of the art, major accomplishments, research programs and facilities, future trends, technology issues, space transportation systems applications and projected technology readiness for those applications. The holes that may exist between the technology needs of the transportation systems versus the research that is currently under way are addressed, and cultural changes that might facilitate the incorporation of these advanced technologies into future space transportation systems are recommended. Some of the objectives are to reduce life cycle costs, improve reliability and fault tolerance, use of standards for the incorporation of advancing technology, and reduction of weight, volume and power. Pilot workload can be reduced and the pilot's situational awareness can be improved, which would result in improved flight safety and operating efficiency. This could be accomplished through the use of integrated, electronic pictorial displays, consolidated controls, artificial intelligence, and human centered automation tools. The Orbiter Glass Cockpit Display is an example examined.

  10. Peripheral i.v. analysis (PIVA) of venous waveforms for volume assessment in patients undergoing haemodialysis.

    Science.gov (United States)

    Hocking, K M; Alvis, B D; Baudenbacher, F; Boyer, R; Brophy, C M; Beer, I; Eagle, S

    2017-12-01

    The assessment of intravascular volume status remains a challenge for clinicians. Peripheral i.v. analysis (PIVA) is a method for analysing the peripheral venous waveform that has been used to monitor volume status. We present a proof-of-concept study for evaluating the efficacy of PIVA in detecting changes in fluid volume. We enrolled 37 hospitalized patients undergoing haemodialysis (HD) as a controlled model for intravascular volume loss. Respiratory rate (F0) and pulse rate (F1) frequencies were measured. PIVA signal was obtained by fast Fourier analysis of the venous waveform followed by weighing the magnitude of the amplitude of the pulse rate frequency. PIVA was compared with peripheral venous pressure and standard monitoring of vital signs. Regression analysis showed a linear correlation between volume loss and change in the PIVA signal (R2=0.77). Receiver operator curves demonstrated that the PIVA signal showed an area under the curve of 0.89 for detection of 20 ml kg-1 change in volume. There was no correlation between volume loss and peripheral venous pressure, blood pressure or pulse rate. PIVA-derived pulse rate and respiratory rate were consistent with similar numbers derived from the bio-impedance and electrical signals from the electrocardiogram. PIVA is a minimally invasive, novel modality for detecting changes in fluid volume status, respiratory rate and pulse rate in spontaneously breathing patients with peripheral i.v. cannulas. © The Author 2017. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  11. Comparison between visual assessment of MTA and hippocampal volumes in an elderly, non-demented population

    Energy Technology Data Exchange (ETDEWEB)

    Cavallin, Lena; Axelsson, Rimma [CLINTEC, Div. of Medical Imaging and Technology, Karolinska Inst., Karolinska Univ. Hospital, Stockholm (Sweden); Dept. of Radiology, Karolinska Univ. Hospital, Stockholm (Sweden)], e-mail: lena.cavallin@karolinska.se; Bronge, Lena [CLINTEC, Div. of Medical Imaging and Technology, Karolinska Inst., Karolinska Univ. Hospital, Stockholm (Sweden); Aleris Diagnostics, Stockholm (Sweden); Zhang, Yi [NVS, Novum, Karolinska Inst., Karolinska Univ. Hospital, Stockholm (Sweden); Oeksengaard, Anne-Rita [NVS, Novum, Karolinska Inst., Karolinska Univ. Hospital, Stockholm (Sweden); Ulleval Univ. Hospital and Asker and Baerum Hospital, Oslo (Norway); Wahlund, Lars-Olof [NVS, Novum, Karolinska Inst., Karolinska Univ. Hospital, Stockholm (Sweden); Swedish Brain Power, Karolinska Univ. Hospital, Stockholm (Sweden); Fratiglioni, Laura [ARC Karolinska Inst. Stockholm (Sweden)

    2012-06-15

    Background: It is important to have a replicable easy method for monitoring atrophy progression in Alzheimer's disease. Volumetric methods for calculating hippocampal volume are time-consuming and commonly used in research. Visual assessments of medial temporal lobe atrophy (vaMTA) is a rapid method for clinical use. This method has not been tested in a large non-demented population in comparison with volumetry measurements. Since hippocampal volume decreases with time even in normal aging there is also a need to study the normal age differences of medial temporal lobe atrophy. Purpose: To compare visual assessment of medial temporal lobe atrophy (vaMTA) with hippocampal volume in a healthy, non-demented elderly population. To describe normal ageing using vaMTA. Material and Methods: Non-demented individuals aged 60, 66, 72, 78, 81, 84, and {>=}87 years old were recruited from the Swedish National study on Ageing and Care in Kungsholmen (SNAC-K), Sweden. Standard magnetic resonance imaging (MRI) scans, vaMTA, and calculations of hippocampal volumes were performed in 544 subjects. Results: Significant correlation (rs = -0.32, P < 0.001, sin; and rs = -0.26, P < 0.001, dx) was found between hippocampal volume measurements and vaMTA. In normal ageing, almost 95% of {<=}66-year-olds had a medial temporal lobe atrophy (MTA) score {<=}1, with possible scores ranging from 0 to 4. Subjects aged 72, 78, and 81 years scored {<=}2, while the two oldest age groups had scores {<=}3. Conclusion: There was a highly significant correlation between volumetric measurements of the hippocampus and MTA scoring. In normal ageing, there is increasing MTA score. For non-demented elderly individuals {<=}70 years, an MTA score of 0-1 may be considered normal, compared with MTA {<=}2 for 70-80-years and MTA 3 for >80-year-old individuals.

  12. Three-Dimensional Photography for Quantitative Assessment of Penile Volume-Loss Deformities in Peyronie's Disease.

    Science.gov (United States)

    Margolin, Ezra J; Mlynarczyk, Carrie M; Mulhall, John P; Stember, Doron S; Stahl, Peter J

    2017-06-01

    Non-curvature penile deformities are prevalent and bothersome manifestations of Peyronie's disease (PD), but the quantitative metrics that are currently used to describe these deformities are inadequate and non-standardized, presenting a barrier to clinical research and patient care. To introduce erect penile volume (EPV) and percentage of erect penile volume loss (percent EPVL) as novel metrics that provide detailed quantitative information about non-curvature penile deformities and to study the feasibility and reliability of three-dimensional (3D) photography for measurement of quantitative penile parameters. We constructed seven penis models simulating deformities found in PD. The 3D photographs of each model were captured in triplicate by four observers using a 3D camera. Computer software was used to generate automated measurements of EPV, percent EPVL, penile length, minimum circumference, maximum circumference, and angle of curvature. The automated measurements were statistically compared with measurements obtained using water-displacement experiments, a tape measure, and a goniometer. Accuracy of 3D photography for average measurements of all parameters compared with manual measurements; inter-test, intra-observer, and inter-observer reliabilities of EPV and percent EPVL measurements as assessed by the intraclass correlation coefficient. The 3D images were captured in a median of 52 seconds (interquartile range = 45-61). On average, 3D photography was accurate to within 0.3% for measurement of penile length. It overestimated maximum and minimum circumferences by averages of 4.2% and 1.6%, respectively; overestimated EPV by an average of 7.1%; and underestimated percent EPVL by an average of 1.9%. All inter-test, inter-observer, and intra-observer intraclass correlation coefficients for EPV and percent EPVL measurements were greater than 0.75, reflective of excellent methodologic reliability. By providing highly descriptive and reliable measurements of

  13. Pathology-based validation of FDG PET segmentation tools for volume assessment of lymph node metastases from head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Schinagl, Dominic A.X. [Radboud University Nijmegen Medical Centre, Department of Radiation Oncology, Nijmegen (Netherlands); Radboud University Nijmegen Medical Centre, Department of Radiation Oncology (874), P.O. Box 9101, Nijmegen (Netherlands); Span, Paul N.; Kaanders, Johannes H.A.M. [Radboud University Nijmegen Medical Centre, Department of Radiation Oncology, Nijmegen (Netherlands); Hoogen, Frank J.A. van den [Radboud University Nijmegen Medical Centre, Department of Otorhinolaryngology, Head and Neck Surgery, Nijmegen (Netherlands); Merkx, Matthias A.W. [Radboud University Nijmegen Medical Centre, Department of Oral and Maxillofacial Surgery, Nijmegen (Netherlands); Slootweg, Piet J. [Radboud University Nijmegen Medical Centre, Department of Pathology, Nijmegen (Netherlands); Oyen, Wim J.G. [Radboud University Nijmegen Medical Centre, Department of Nuclear Medicine, Nijmegen (Netherlands)

    2013-12-15

    FDG PET is increasingly incorporated into radiation treatment planning of head and neck cancer. However, there are only limited data on the accuracy of radiotherapy target volume delineation by FDG PET. The purpose of this study was to validate FDG PET segmentation tools for volume assessment of lymph node metastases from head and neck cancer against the pathological method as the standard. Twelve patients with head and neck cancer and 28 metastatic lymph nodes eligible for therapeutic neck dissection underwent preoperative FDG PET/CT. The metastatic lymph nodes were delineated on CT (Node{sub CT}) and ten PET segmentation tools were used to assess FDG PET-based nodal volumes: interpreting FDG PET visually (PET{sub VIS}), applying an isocontour at a standardized uptake value (SUV) of 2.5 (PET{sub SUV}), two segmentation tools with a fixed threshold of 40 % and 50 %, and two adaptive threshold based methods. The latter four tools were applied with the primary tumour as reference and also with the lymph node itself as reference. Nodal volumes were compared with the true volume as determined by pathological examination. Both Node{sub CT} and PET{sub VIS} showed good correlations with the pathological volume. PET segmentation tools using the metastatic node as reference all performed well but not better than PET{sub VIS}. The tools using the primary tumour as reference correlated poorly with pathology. PET{sub SUV} was unsatisfactory in 35 % of the patients due to merging of the contours of adjacent nodes. FDG PET accurately estimates metastatic lymph node volume, but beyond the detection of lymph node metastases (staging), it has no added value over CT alone for the delineation of routine radiotherapy target volumes. If FDG PET is used in radiotherapy planning, treatment adaptation or response assessment, we recommend an automated segmentation method for purposes of reproducibility and interinstitutional comparison. (orig.)

  14. A Sustainability Assessment Methodology for Prioritizing the Technologies of Groundwater Contamination Remediation

    DEFF Research Database (Denmark)

    An, Da; Xi, Beidou; Wang, Yue

    2016-01-01

    More and more groundwater has 23 been polluted recently, and technologies for groundwater contamination remediation are of vital importance; however, it is usually difficult for the users to select the most suitable technology among multiple alternatives. In order to address this, this study aims...... at developing a sustainability assessment framework for prioritizing the technologies for groundwater contamination remediation by combining the concept of sustainability and multi-criteria decision making (MCDM) method. A criterion system which consists of six criteria in three aspects has been proposed...... for sustainability assessment of technologies for groundwater contamination remediation, and a novel MCDM method by combining the logarithmic fuzzy preference programming based fuzzy analytic hierarchy process and the improved ELECTRE method has been developed for prioritizing the alternatives. In order...

  15. Technology Readiness Level Assessment Process as Applied to NASA Earth Science Missions

    Science.gov (United States)

    Leete, Stephen J.; Romero, Raul A.; Dempsey, James A.; Carey, John P.; Cline, Helmut P.; Lively, Carey F.

    2015-01-01

    Technology assessments of fourteen science instruments were conducted within NASA using the NASA Technology Readiness Level (TRL) Metric. The instruments were part of three NASA Earth Science Decadal Survey missions in pre-formulation. The Earth Systematic Missions Program (ESMP) Systems Engineering Working Group (SEWG), composed of members of three NASA Centers, provided a newly modified electronic workbook to be completed, with instructions. Each instrument development team performed an internal assessment of its technology status, prepared an overview of its instrument, and completed the workbook with the results of its assessment. A team from the ESMP SEWG met with each instrument team and provided feedback. The instrument teams then reported through the Program Scientist for their respective missions to NASA's Earth Science Division (ESD) on technology readiness, taking the SEWG input into account. The instruments were found to have a range of TRL from 4 to 7. Lessons Learned are presented; however, due to the competition-sensitive nature of the assessments, the results for specific missions are not presented. The assessments were generally successful, and produced useful results for the agency. The SEWG team identified a number of potential improvements to the process. Particular focus was on ensuring traceability to guiding NASA documents, including the NASA Systems Engineering Handbook. The TRL Workbook has been substantially modified, and the revised workbook is described.

  16. Environmental assessment of solid waste systems and technologies: EASEWASTE

    DEFF Research Database (Denmark)

    Kirkeby, Janus Torsten; Birgisdottir, Harpa; Hansen, Trine Lund

    2006-01-01

    A new model has been developed for evaluating the overall resource consumption and environmental impacts of municipal solid waste management systems by the use of life cycle assessment. The model is named EASEWASTE (Environmental Assessment of Solid Waste Systems and Technologies) and is able...... may not always be the most environmentally friendly. The EASEWASTE model can identify the most environmentally sustainable solution, which may differ among waste materials and regions and can add valuable information about environmental achievements from each process in a solid waste management system....... to compare different waste management strategies, waste treatment methods and waste process technologies. The potential environmental impacts can be traced back to the most important processes and waste fractions that contribute to the relevant impacts. A model like EASEWASTE can be used by waste planners...

  17. A model for assessing information technology effectiveness in the business environment

    Directory of Open Access Journals (Sweden)

    Sandra Cristina Riascos Erazo

    2008-05-01

    Full Text Available The impact of technology on administrative processes has improved business strategies (especially regarding the e-ffect of information technology - IT, often leading to organisational success. Its effectiveness in this environment was thus modelled due to such importance; this paper describes studying a series of models aimed at assessing IT, its ad-vantages and disadvantages. A model is proposed involving different aspects for an integral assessment of IT effecti-veness and considering administrative activities’ particular characteristics. This analytical study provides guidelines for identifying IT effectiveness in a business environment and current key strategies in technological innovation. This stu-dy was based on ISO 9126, ISO 9001, ISO 15939 and ISO 25000 standards as well as COBIT and CMM stan-dards.

  18. Pyrolysis and gasification of waste: a worldwide technology and business review. Vol.1: Markets and trends; Vol. 2: Technologies and processes

    International Nuclear Information System (INIS)

    2000-01-01

    The two volume report, Pyrolysis and Gasification of Waste; a Worldwide Technology and Business Review, covers technology trends and market forces, applications and markets, market profiles by region, decision makers' preferences, and the market forecast for 1999 to 2008 in Volume I. Technologies and processes are addressed in Volume II, with technology concepts, analysis of the processes, a comparative review of selected processes examined. A directory of suppliers, process developers and licenses is provided in the appendices to Volume II. (UK)

  19. Development of modelling algorithm of technological systems by statistical tests

    Science.gov (United States)

    Shemshura, E. A.; Otrokov, A. V.; Chernyh, V. G.

    2018-03-01

    The paper tackles the problem of economic assessment of design efficiency regarding various technological systems at the stage of their operation. The modelling algorithm of a technological system was performed using statistical tests and with account of the reliability index allows estimating the level of machinery technical excellence and defining the efficiency of design reliability against its performance. Economic feasibility of its application shall be determined on the basis of service quality of a technological system with further forecasting of volumes and the range of spare parts supply.

  20. Melter Technologies Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Perez, J.M. Jr. [Pacific Northwest National Lab., Richland, WA (United States); Schumacher, R.F. [Savannah River Technology Center, Aiken, SC (United States); Forsberg, C.W. [Oak Ridge National Lab., TN (United States)

    1996-05-01

    The problem of controlling and disposing of surplus fissile material, in particular plutonium, is being addressed by the US Department of Energy (DOE). Immobilization of plutonium by vitrification has been identified as a promising solution. The Melter Evaluation Activity of DOE`s Plutonium Immobilization Task is responsible for evaluating and selecting the preferred melter technologies for vitrification for each of three immobilization options: Greenfield Facility, Adjunct Melter Facility, and Can-In-Canister. A significant number of melter technologies are available for evaluation as a result of vitrification research and development throughout the international communities for over 20 years. This paper describes an evaluation process which will establish the specific requirements of performance against which candidate melter technologies can be carefully evaluated. Melter technologies that have been identified are also described.

  1. Mars power system concept definition study. Volume 2: Appendices

    Science.gov (United States)

    Littman, Franklin D.

    1994-01-01

    This report documents the work performed by Rockwell International's Rocketdyne Division on NASA Contract No. NAS3-25808 (Task Order No. 16) entitled 'Mars Power System Definition Study'. This work was performed for NASA's Lewis Research Center (LeRC). The report is divided into two volumes as follows: Volume 1 - Study Results; and Volume 2 - Appendices. The results of the power system characterization studies, operations studies, and technology evaluations are summarized in Volume 1. The appendices include complete, standalone technology development plans for each candidate power system that was investigated.

  2. Predicting adult pulmonary ventilation volume and wearing complianceby on-board accelerometry during personal level exposure assessments

    Science.gov (United States)

    Rodes, C. E.; Chillrud, S. N.; Haskell, W. L.; Intille, S. S.; Albinali, F.; Rosenberger, M. E.

    2012-09-01

    BackgroundMetabolic functions typically increase with human activity, but optimal methods to characterize activity levels for real-time predictions of ventilation volume (l min-1) during exposure assessments have not been available. Could tiny, triaxial accelerometers be incorporated into personal level monitors to define periods of acceptable wearing compliance, and allow the exposures (μg m-3) to be extended to potential doses in μg min-1 kg-1 of body weight? ObjectivesIn a pilot effort, we tested: 1) whether appropriately-processed accelerometer data could be utilized to predict compliance and in linear regressions to predict ventilation volumes in real-time as an on-board component of personal level exposure sensor systems, and 2) whether locating the exposure monitors on the chest in the breathing zone, provided comparable accelerometric data to other locations more typically utilized (waist, thigh, wrist, etc.). MethodsPrototype exposure monitors from RTI International and Columbia University were worn on the chest by a pilot cohort of adults while conducting an array of scripted activities (all volumes in-situ. For the subset of participants with complete data (n = 22), linear regressions were constructed (processed accelerometric variable versus ventilation rate) for each participant and exposure monitor type, and Pearson correlations computed to compare across scenarios. ResultsTriaxial accelerometer data were demonstrated to be adequately sensitive indicators for predicting exposure monitor wearing compliance. Strong linear correlations (R values from 0.77 to 0.99) were observed for all participants for both exposure sensor accelerometer variables against ventilation volume for recumbent, sedentary, and ambulatory activities with MET values ˜volume data. Computing accelerometric standard deviations allowed good sensitivity for compliance assessments even for sedentary activities. These pilot findings supported the hypothesis that a common linear

  3. Building Future Security: Strategies for Restructuring the Defense Technology and Industrial Base.

    Science.gov (United States)

    1992-06-01

    Affairs Staffs Group General Motors Corporation Detroit, Michigan Director JOHN H. GIBBONS The Technology Assessment Board approves the release...Chairman & CEO Technology, Strategies & Alliances Donald W Putnam Corporate Director of Contracts General Dynamics Corp. Jack Ruina Professor of...parts. This strategy allowed Mazda to bring a new product to market quickly and make a profit despite low volume sales. (Peter F. Drucker, "The Big Three

  4. A State-of-the-Art Report on Technologies of a Safety Assessment and a Radioactivity Exposure Assessment for the Decommissioning Process of Nuclear Facilities

    International Nuclear Information System (INIS)

    Jeong, Kwan Seong; Kang, Young Ae; Lee, Dong Gyu; Lee, Kune Woo; Jung, Chong Hun

    2007-09-01

    This report is to provide the reference contents of research and development for technologies of radioactivity exposure and safety assessment for development of the decommissioning technology for nuclear facilities. This report consists of as follows: - Analyzing and discussing on state-of-the-art technologies of a radioactivity exposure assessment of a decommissioning for nuclear facilities - Analyzing and discussing on state-of-the-art technologies of a safety assessment of a decommissioning for nuclear facilities

  5. A State-of-the-Art Report on Technologies of a Safety Assessment and a Radioactivity Exposure Assessment for the Decommissioning Process of Nuclear Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Kwan Seong; Kang, Young Ae; Lee, Dong Gyu; Lee, Kune Woo; Jung, Chong Hun

    2007-09-15

    This report is to provide the reference contents of research and development for technologies of radioactivity exposure and safety assessment for development of the decommissioning technology for nuclear facilities. This report consists of as follows: - Analyzing and discussing on state-of-the-art technologies of a radioactivity exposure assessment of a decommissioning for nuclear facilities - Analyzing and discussing on state-of-the-art technologies of a safety assessment of a decommissioning for nuclear facilities.

  6. A Conceptual Methodology for Assessing Acquisition Requirements Robustness against Technology Uncertainties

    Science.gov (United States)

    Chou, Shuo-Ju

    2011-12-01

    In recent years the United States has shifted from a threat-based acquisition policy that developed systems for countering specific threats to a capabilities-based strategy that emphasizes the acquisition of systems that provide critical national defense capabilities. This shift in policy, in theory, allows for the creation of an "optimal force" that is robust against current and future threats regardless of the tactics and scenario involved. In broad terms, robustness can be defined as the insensitivity of an outcome to "noise" or non-controlled variables. Within this context, the outcome is the successful achievement of defense strategies and the noise variables are tactics and scenarios that will be associated with current and future enemies. Unfortunately, a lack of system capability, budget, and schedule robustness against technology performance and development uncertainties has led to major setbacks in recent acquisition programs. This lack of robustness stems from the fact that immature technologies have uncertainties in their expected performance, development cost, and schedule that cause to variations in system effectiveness and program development budget and schedule requirements. Unfortunately, the Technology Readiness Assessment process currently used by acquisition program managers and decision-makers to measure technology uncertainty during critical program decision junctions does not adequately capture the impact of technology performance and development uncertainty on program capability and development metrics. The Technology Readiness Level metric employed by the TRA to describe program technology elements uncertainties can only provide a qualitative and non-descript estimation of the technology uncertainties. In order to assess program robustness, specifically requirements robustness, against technology performance and development uncertainties, a new process is needed. This process should provide acquisition program managers and decision

  7. National Wind Technology Center sitewide, Golden, CO: Environmental assessment

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-11-01

    The National Renewable Energy Laboratory (NREL), the nation`s primary solar and renewable energy research laboratory, proposes to expand its wind technology research and development program activities at its National Wind Technology Center (NWTC) near Golden, Colorado. NWTC is an existing wind energy research facility operated by NREL for the US Department of Energy (DOE). Proposed activities include the construction and reuse of buildings and facilities, installation of up to 20 wind turbine test sites, improvements in infrastructure, and subsequent research activities, technology testing, and site operations. In addition to wind turbine test activities, NWTC may be used to support other NREL program activities and small-scale demonstration projects. This document assesses potential consequences to resources within the physical, biological, and human environment, including potential impacts to: air quality, geology and soils, water resources, biological resources, cultural and historic resources, socioeconomic resources, land use, visual resources, noise environment, hazardous materials and waste management, and health and safety conditions. Comment letters were received from several agencies in response to the scoping and predecisional draft reviews. The comments have been incorporated as appropriate into the document with full text of the letters contained in the Appendices. Additionally, information from the Rocky Flats Environmental Technology Site on going sitewide assessment of potential environmental impacts has been reviewed and discussed by representatives of both parties and incorporated into the document as appropriate.

  8. National Wind Technology Center sitewide, Golden, CO: Environmental assessment

    International Nuclear Information System (INIS)

    1996-11-01

    The National Renewable Energy Laboratory (NREL), the nation's primary solar and renewable energy research laboratory, proposes to expand its wind technology research and development program activities at its National Wind Technology Center (NWTC) near Golden, Colorado. NWTC is an existing wind energy research facility operated by NREL for the US Department of Energy (DOE). Proposed activities include the construction and reuse of buildings and facilities, installation of up to 20 wind turbine test sites, improvements in infrastructure, and subsequent research activities, technology testing, and site operations. In addition to wind turbine test activities, NWTC may be used to support other NREL program activities and small-scale demonstration projects. This document assesses potential consequences to resources within the physical, biological, and human environment, including potential impacts to: air quality, geology and soils, water resources, biological resources, cultural and historic resources, socioeconomic resources, land use, visual resources, noise environment, hazardous materials and waste management, and health and safety conditions. Comment letters were received from several agencies in response to the scoping and predecisional draft reviews. The comments have been incorporated as appropriate into the document with full text of the letters contained in the Appendices. Additionally, information from the Rocky Flats Environmental Technology Site on going sitewide assessment of potential environmental impacts has been reviewed and discussed by representatives of both parties and incorporated into the document as appropriate

  9. Can we reliably benchmark health technology assessment organizations?

    Science.gov (United States)

    Drummond, Michael; Neumann, Peter; Jönsson, Bengt; Luce, Bryan; Schwartz, J Sanford; Siebert, Uwe; Sullivan, Sean D

    2012-04-01

    In recent years, there has been growth in the use of health technology assessment (HTA) for making decisions about the reimbursement, coverage, or guidance on the use of health technologies. Given this greater emphasis on the use of HTA, it is important to develop standards of good practice and to benchmark the various HTA organizations against these standards. This study discusses the conceptual and methodological challenges associated with benchmarking HTA organizations and proposes a series of audit questions based on a previously published set of principles of good practice. It is concluded that a benchmarking exercise would be feasible and useful, although the question of who should do the benchmarking requires further discussion. Key issues for further research are the alternative methods for weighting the various principles and for generating an overall score, or summary statement of adherence to the principles. Any weighting system, if developed, would need to be explored in different jurisdictions to assess the extent to which the relative importance of the principles is perceived to vary. Finally, the development and precise wording of the audit questions requires further study, with a view to making the questions as unambiguous as possible, and the reproducibility of the assessments as high as possible.

  10. PRELIMINARY ASSESSMENT OF THE LOW-TEMPERATURE WASTE FORM TECHNOLOGY COUPLED WITH TECHNETIUM REMOVAL

    Energy Technology Data Exchange (ETDEWEB)

    Fox, K.

    2014-05-13

    The U.S. Department of Energy Office of Environmental Management (EM) is engaging the national laboratories to provide the scientific and technological rigor to support EM program and project planning, technology development and deployment, project execution, and assessment of program outcomes. As an early demonstration of this new responsibility, Pacific Northwest National Laboratory (PNNL) and Savannah River National Laboratory (SRNL) have been chartered to implement a science and technology program addressing low-temperature waste forms for immobilization of DOE aqueous waste streams, including technetium removal as an implementing technology. As a first step, the laboratories examined the technical risks and uncertainties associated with the Cast Stone waste immobilization projects at Hanford. Science and technology needs were identified for work associated with 1) conducting performance assessments and risk assessments of waste form and disposal system performance, and 2) technetium chemistry in tank wastes and separations of technetium from waste processing streams. Technical approaches to address the science and technology needs were identified and an initial sequencing priority was suggested. The following table summarizes the most significant science and technology needs and associated approaches to address those needs. These approaches and priorities will be further refined and developed as strong integrated teams of researchers from national laboratories, contractors, industry, and academia are brought together to provide the best science and technology solutions. Implementation of a science and technology program that addresses these needs by pursuing the identified approaches will have immediate benefits to DOE in reducing risks and uncertainties associated with near-term decisions regarding supplemental immobilization at Hanford. Longer term, the work has the potential for cost savings and for providing a strong technical foundation for future

  11. Using technology to assess and intervene with illicit drug-using persons at risk for HIV.

    Science.gov (United States)

    Horvath, Keith J; Lammert, Sara; LeGrand, Sara; Muessig, Kathryn E; Bauermeister, José A

    2017-09-01

    This review describes recent literature on novel ways technology is used for assessment of illicit drug use and HIV risk behaviours, suggestions for optimizing intervention acceptability, and recently completed and ongoing technology-based interventions for drug-using persons at risk for HIV and others with high rates of drug use and HIV risk behaviour. Among studies (n = 5) comparing technology-based to traditional assessment methods, those using Ecological Momentary Assessment (EMA) had high rates of reported drug use and high concordance with traditional assessment methods. The two recent studies assessing the acceptability of mHealth approaches overall demonstrate high interest in these approaches. Current or in-progress technology-based interventions (n = 8) are delivered using mobile apps (n = 5), text messaging (n = 2) and computers (n = 1). Most intervention studies are in progress or do not report intervention outcomes; the results from one efficacy trial showed significantly higher HIV testing rates among persons in need of drug treatment. Studies are needed to continually assess technology adoption and intervention preferences among drug-using populations to ensure that interventions are appropriately matched to users. Large-scale technology-based intervention trials to assess the efficacy of these approaches, as well as the impact of individual intervention components, on drug use and other high-risk behaviours are recommended.

  12. Economic Feasibility and Market Readiness of Solar Technologies. Draft Final Report. Volume I.

    Energy Technology Data Exchange (ETDEWEB)

    Flaim, Silvio J.; Buchanan, Deborah L.; Christmas, Susan; Fellhauer, Cheryl; Glenn, Barbara; Ketels, Peter A.; Levary, Arnon; Mourning, Pete; Steggerda, Paul; Trivedi, Harit; Witholder, Robert E.

    1978-09-01

    Systems descriptions, costs, technical and market readiness assessments are reported for ten solar technologies: solar heating and cooling of buildings (SHACOB), passive, agricultural and industrial process heat (A/IPH), biomass, ocean thermal (OTEC), wind (WECS), solar thermal electric, photovoltaics, satellite power station (SPS), and solar total energy systems (STES). Study objectives, scope, and methods. are presented. of Joint Task The cost and market analyses portion 5213/6103 will be used to make commercialization assessments in the conclusions of. the final report.

  13. Feasibility of Commercially Available, Fully Automated Hepatic CT Volumetry for Assessing Both Total and Territorial Liver Volumes in Liver Transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Cheong Il; Kim, Se Hyung; Rhim, Jung Hyo; Yi, Nam Joon; Suh, Kyung Suk; Lee, Jeong Min; Han, Joon Koo; Choi, Byung Ihn [Seoul National University Hospital, Seoul (Korea, Republic of)

    2013-02-15

    To assess the feasibility of commercially-available, fully automated hepatic CT volumetry for measuring both total and territorial liver volumes by comparing with interactive manual volumetry and measured ex-vivo liver volume. For the assessment of total and territorial liver volume, portal phase CT images of 77 recipients and 107 donors who donated right hemiliver were used. Liver volume was measured using both the fully automated and interactive manual methods with Advanced Liver Analysis software. The quality of the automated segmentation was graded on a 4-point scale. Grading was performed by two radiologists in consensus. For the cases with excellent-to-good quality, the accuracy of automated volumetry was compared with interactive manual volumetry and measured ex-vivo liver volume which was converted from weight using analysis of variance test and Pearson's or Spearman correlation test. Processing time for both automated and interactive manual methods was also compared. Excellent-to-good quality of automated segmentation for total liver and right hemiliver was achieved in 57.1% (44/77) and 17.8% (19/107), respectively. For both total and right hemiliver volumes, there were no significant differences among automated, manual, and ex-vivo volumes except between automate volume and manual volume of the total liver (p = 0.011). There were good correlations between automate volume and ex-vivo liver volume ({gamma}= 0.637 for total liver and {gamma}= 0.767 for right hemiliver). Both correlation coefficients were higher than those with manual method. Fully automated volumetry required significantly less time than interactive manual method (total liver: 48.6 sec vs. 53.2 sec, right hemiliver: 182 sec vs. 244.5 sec). Fully automated hepatic CT volumetry is feasible and time-efficient for total liver volume measurement. However, its usefulness for territorial liver volumetry needs to be improved.

  14. Feasibility of Commercially Available, Fully Automated Hepatic CT Volumetry for Assessing Both Total and Territorial Liver Volumes in Liver Transplantation

    International Nuclear Information System (INIS)

    Shin, Cheong Il; Kim, Se Hyung; Rhim, Jung Hyo; Yi, Nam Joon; Suh, Kyung Suk; Lee, Jeong Min; Han, Joon Koo; Choi, Byung Ihn

    2013-01-01

    To assess the feasibility of commercially-available, fully automated hepatic CT volumetry for measuring both total and territorial liver volumes by comparing with interactive manual volumetry and measured ex-vivo liver volume. For the assessment of total and territorial liver volume, portal phase CT images of 77 recipients and 107 donors who donated right hemiliver were used. Liver volume was measured using both the fully automated and interactive manual methods with Advanced Liver Analysis software. The quality of the automated segmentation was graded on a 4-point scale. Grading was performed by two radiologists in consensus. For the cases with excellent-to-good quality, the accuracy of automated volumetry was compared with interactive manual volumetry and measured ex-vivo liver volume which was converted from weight using analysis of variance test and Pearson's or Spearman correlation test. Processing time for both automated and interactive manual methods was also compared. Excellent-to-good quality of automated segmentation for total liver and right hemiliver was achieved in 57.1% (44/77) and 17.8% (19/107), respectively. For both total and right hemiliver volumes, there were no significant differences among automated, manual, and ex-vivo volumes except between automate volume and manual volume of the total liver (p = 0.011). There were good correlations between automate volume and ex-vivo liver volume (γ= 0.637 for total liver and γ= 0.767 for right hemiliver). Both correlation coefficients were higher than those with manual method. Fully automated volumetry required significantly less time than interactive manual method (total liver: 48.6 sec vs. 53.2 sec, right hemiliver: 182 sec vs. 244.5 sec). Fully automated hepatic CT volumetry is feasible and time-efficient for total liver volume measurement. However, its usefulness for territorial liver volumetry needs to be improved.

  15. On the volume of cremated remains

    DEFF Research Database (Denmark)

    Harvig, Lise Lock; Lynnerup, Niels

    2013-01-01

    Harvig, L., Lynnerup, N. 2013. On the effective volume of prehistoric cremains - a comparative study of cremated bone volume measured manually and assessed by Computed Tomography. Journal of Archaeological Science 40, p. 2713–2722.......Harvig, L., Lynnerup, N. 2013. On the effective volume of prehistoric cremains - a comparative study of cremated bone volume measured manually and assessed by Computed Tomography. Journal of Archaeological Science 40, p. 2713–2722....

  16. Cradle-to-Grave Lifecycle Analysis of U.S. Light-Duty Vehicle-Fuel Pathways: A Greenhouse Gas Emissions and Economic Assessment of Current (2015) and Future (2025-2030) Technologies

    International Nuclear Information System (INIS)

    Elgowainy, Amgad; Han, Jeongwoo; Ward, Jacob; Joseck, Fred; Gohlke, David; Lindauer, Alicia; Ramsden, Todd; Biddy, Mary; Alexander, Marcus; Barnhart, Steven; Sutherland, Ian; Verduzco, Laura; Wallington, Timothy J.

    2016-01-01

    This study provides a comprehensive life-cycle analysis (LCA), or cradle-to-grave (C2G) analysis, of the cost and greenhouse gas (GHG) emissions of a variety of vehicle-fuel pathways, as well as the levelized cost of driving (LCD) and cost of avoided GHG emissions. This study also estimates the technology readiness levels (TRLs) of key fuel and vehicle technologies along the pathways. The C2G analysis spans a full portfolio of midsize light-duty vehicles (LDVs), including conventional internal combustion engine vehicles (ICEVs), flexible fuel vehicles (FFVs), hybrid electric vehicles (HEVs), plug-in hybrid electric vehicles (PHEVs), battery electric vehicles (BEVs), and fuel cell electric vehicles (FCEVs). In evaluating the vehicle-fuel combinations, this study considers both low-volume and high-volume ''CURRENT TECHNOLOGY'' cases (nominally 2015) and a high-volume ''FUTURE TECHNOLOGY'' lower-carbon case (nominally 2025-2030). For the CURRENT TECHNOLOGY case, low-volume vehicle and fuel production pathways are examined to determine costs in the near term.

  17. Contemporary design and manufacturing technology

    CERN Document Server

    Wang, Taiyong; Zuo, Dunwen

    2013-01-01

    The special topic volume communicates the latest progress and research results of new theory, new technology, method, equipment and so on in Engineering Technology, and to grasp the updated technological and research trends in internationally. The major topics covered by the special volumes include Advanced Materials and Manufacturing Technologies, Control, Automation and Detection Systems, Advanced Design Technology, Optimization and Modeling. In 80 invited and peer-reviewed papers, mechanical and other engineers describe their recent and current research and results in advanced materials and

  18. Assessing systemwide occupational health and safety risks of energy technologies

    International Nuclear Information System (INIS)

    Rowe, M.D.

    1982-01-01

    Input-output modelling is now being used to assess systemwide occupational and public health and safety risks of energy technologies. Some of the advantages and disadvantages of this method are presented and some of its important limitations are discussed. Its primary advantage is that it provides a standard method with which to compare technologies on a consistent basis without extensive economic analysis. Among the disadvantages are limited range of applicability, limited spectrum of health impacts, and inability to identify unusual health impacts unique to a new technology. (author)

  19. Assessment of research needs for advanced heterogeneous catalysts for energy applications. Final report: Volume 2, Topic reports

    Energy Technology Data Exchange (ETDEWEB)

    Mills, G.A.

    1994-04-01

    This report assesses the direction, technical content, and priority of research needs judged to provide the best chance of yielding new and improved heterogeneous catalysts for energy-related applications over the period of 5-20 years. It addresses issues of energy conservation, alternate fuels and feedstocks, and the economics and applications that could alleviate pollution from energy processes. Recommended goals are defined in 3 research thrusts: catalytic science, environmental protection by catalysis, and industrial catalytic applications. This study was conducted by an 11-member panel of experts from industry and academia, including one each from Japan and Europe. This volume first presents an in-depth overview of the role of catalysis in future energy technology in chapter 1; then current catalytic research is critically reviewed and research recommended in 8 topic chapters: catalyst preparation (design and synthesis), catalyst characterization (structure/function), catalyst performance testing, reaction kinetics/reactor design, catalysis for industrial chemicals, catalysis for electrical applications (clean fuels, pollution remediation), catalysis for control of exhaust emissions, and catalysts for liquid transportation fuels from petroleum, coal, residual oil, and biomass.

  20. 1988 DOE model conference proceedings: Volume 4

    Energy Technology Data Exchange (ETDEWEB)

    1988-01-01

    These Proceedings of the October 3-7, 1988, DOE Model Conference are a compilation of the papers that were presented in the technical or poster sessions at the conference. Papers and posters not submitted for publication are not included in the Proceedings. The Table of Contents lists the titles of papers as well as the names of the presenters. These individuals are not, in all cases, the primary authors of the papers published. The actual title pages, appearing later with the papers, show the primary author(s) and all co-authors. The papers in all three volumes of the Proceedings appear as they were originally submitted for publication and have not been edited or changed in any way. Topics discussed in Volume 4 include site characterization and remediation projects, environmental monitoring and modeling; disposal site selection and facility design, risk assessment, safety and health issues, and site remediation technology.

  1. 1988 DOE model conference proceedings: Volume 4

    International Nuclear Information System (INIS)

    1988-01-01

    These Proceedings of the October 3-7, 1988, DOE Model Conference are a compilation of the papers that were presented in the technical or poster sessions at the conference. Papers and posters not submitted for publication are not included in the Proceedings. The Table of Contents lists the titles of papers as well as the names of the presenters. These individuals are not, in all cases, the primary authors of the papers published. The actual title pages, appearing later with the papers, show the primary author(s) and all co-authors. The papers in all three volumes of the Proceedings appear as they were originally submitted for publication and have not been edited or changed in any way. Topics discussed in Volume 4 include site characterization and remediation projects, environmental monitoring and modeling; disposal site selection and facility design, risk assessment, safety and health issues, and site remediation technology

  2. Oak Ridge K-25 Site Technology Logic Diagram

    Energy Technology Data Exchange (ETDEWEB)

    Fellows, R.L. (ed.)

    1993-02-26

    The Oak Ridge K-25 Technology Logic Diagram (TLD), a decision support tool for the K-25 Site, was developed to provide a planning document that relates environmental restoration (ER) and waste management (WN) problems at the Oak Ridge K-25 Site. The TLD technique identifies the research necessary to develop these technologies to a state that allows for technology transfer and application to waste management, remediation, decontamination, and decommissioning activities. The TLD consists of four separate volumes-Vol. 1, Vol. 2, Vol. 3A, and Vol. 3B. Volume 1 provides introductory and overview information about the TLD. Volume 2 contains logic diagrams. Volume 3 has been divided into two separate volumes to facilitate handling and use. This volume 3 B provides the Technology Evaluation Data Sheets (TEDS) for ER/WM activities (Remedial Action Robotics and Automation, Waste Management) that are referenced by a TEDS code number in Vol. 2 of the TLD. Each of these sheets represents a single logic trace across the TLD. These sheets contain more detail than each technology in Vol. 2. The TEDS are arranged alphanumerically by the TEDS code number in the upper right corner of each data sheet. Volume 3 can be used in two ways: (1) technologies that are identified from Vol. 2 can be referenced directly in Vol. 3 by using the TEDS codes, and (2) technologies and general technology areas (alternatives) can be located in the index in the front of this volume.

  3. Sodium fast reactor safety and licensing research plan - Volume II

    International Nuclear Information System (INIS)

    Ludewig, H.; Powers, D.A.; Hewson, John C.; LaChance, Jeffrey L.; Wright, A.; Phillips, J.; Zeyen, R.; Clement, B.; Garner, Frank; Walters, Leon; Wright, Steve; Ott, Larry J.; Suo-Anttila, Ahti Jorma; Denning, Richard; Ohshima, Hiroyuki; Ohno, S.; Miyhara, S.; Yacout, Abdellatif; Farmer, M.; Wade, D.; Grandy, C.; Schmidt, R.; Cahalen, J.; Olivier, Tara Jean; Budnitz, R.; Tobita, Yoshiharu; Serre, Frederic; Natesan, Ken; Carbajo, Juan J.; Jeong, Hae-Yong; Wigeland, Roald; Corradini, Michael; Thomas, Justin; Wei, Tom; Sofu, Tanju; Flanagan, George F.; Bari, R.; Porter D.

    2012-01-01

    Expert panels comprised of subject matter experts identified at the U.S. National Laboratories (SNL, ANL, INL, ORNL, LBL, and BNL), universities (University of Wisconsin and Ohio State University), international agencies (IRSN, CEA, JAEA, KAERI, and JRC-IE) and private consultation companies (Radiation Effects Consulting) were assembled to perform a gap analysis for sodium fast reactor licensing. Expert-opinion elicitation was performed to qualitatively assess the current state of sodium fast reactor technologies. Five independent gap analyses were performed resulting in the following topical reports: (1) Accident Initiators and Sequences (i.e., Initiators/Sequences Technology Gap Analysis), (2) Sodium Technology Phenomena (i.e., Advanced Burner Reactor Sodium Technology Gap Analysis), (3) Fuels and Materials (i.e., Sodium Fast Reactor Fuels and Materials: Research Needs), (4) Source Term Characterization (i.e., Advanced Sodium Fast Reactor Accident Source Terms: Research Needs), and (5) Computer Codes and Models (i.e., Sodium Fast Reactor Gaps Analysis of Computer Codes and Models for Accident Analysis and Reactor Safety). Volume II of the Sodium Research Plan consolidates the five gap analysis reports produced by each expert panel, wherein the importance of the identified phenomena and necessities of further experimental research and code development were addressed. The findings from these five reports comprised the basis for the analysis in Sodium Fast Reactor Research Plan Volume I.

  4. Sodium fast reactor safety and licensing research plan. Volume II.

    Energy Technology Data Exchange (ETDEWEB)

    Ludewig, H. (Brokhaven National Laboratory, Upton, NY); Powers, D. A.; Hewson, John C.; LaChance, Jeffrey L.; Wright, A. (Argonne National Laboratory, Argonne, IL); Phillips, J.; Zeyen, R. (Institute for Energy Petten, Saint-Paul-lez-Durance, France); Clement, B. (IRSN/DPAM.SEMIC Bt 702, Saint-Paul-lez-Durance, France); Garner, Frank (Radiation Effects Consulting, Richland, WA); Walters, Leon (Advanced Reactor Concepts, Los Alamos, NM); Wright, Steve; Ott, Larry J. (Oak Ridge National Laboratory, Oak Ridge, TN); Suo-Anttila, Ahti Jorma; Denning, Richard (Ohio State University, Columbus, OH); Ohshima, Hiroyuki (Japan Atomic Energy Agency, Ibaraki, Japan); Ohno, S. (Japan Atomic Energy Agency, Ibaraki, Japan); Miyhara, S. (Japan Atomic Energy Agency, Ibaraki, Japan); Yacout, Abdellatif (Argonne National Laboratory, Argonne, IL); Farmer, M. (Argonne National Laboratory, Argonne, IL); Wade, D. (Argonne National Laboratory, Argonne, IL); Grandy, C. (Argonne National Laboratory, Argonne, IL); Schmidt, R.; Cahalen, J. (Argonne National Laboratory, Argonne, IL); Olivier, Tara Jean; Budnitz, R. (Lawrence Berkeley National Laboratory, Berkeley, CA); Tobita, Yoshiharu (Japan Atomic Energy Agency, Ibaraki, Japan); Serre, Frederic (Centre d' %C3%94etudes nucl%C3%94eaires de Cadarache, Cea, France); Natesan, Ken (Argonne National Laboratory, Argonne, IL); Carbajo, Juan J. (Oak Ridge National Laboratory, Oak Ridge, TN); Jeong, Hae-Yong (Korea Atomic Energy Research Institute, Daejeon, Korea); Wigeland, Roald (Idaho National Laboratory, Idaho Falls, ID); Corradini, Michael (University of Wisconsin-Madison, Madison, WI); Thomas, Justin (Argonne National Laboratory, Argonne, IL); Wei, Tom (Argonne National Laboratory, Argonne, IL); Sofu, Tanju (Argonne National Laboratory, Argonne, IL); Flanagan, George F. (Oak Ridge National Laboratory, Oak Ridge, TN); Bari, R. (Brokhaven National Laboratory, Upton, NY); Porter D. (Idaho National Laboratory, Idaho Falls, ID); Lambert, J. (Argonne National Laboratory, Argonne, IL); Hayes, S. (Idaho National Laboratory, Idaho Falls, ID); Sackett, J. (Idaho National Laboratory, Idaho Falls, ID); Denman, Matthew R.

    2012-05-01

    Expert panels comprised of subject matter experts identified at the U.S. National Laboratories (SNL, ANL, INL, ORNL, LBL, and BNL), universities (University of Wisconsin and Ohio State University), international agencies (IRSN, CEA, JAEA, KAERI, and JRC-IE) and private consultation companies (Radiation Effects Consulting) were assembled to perform a gap analysis for sodium fast reactor licensing. Expert-opinion elicitation was performed to qualitatively assess the current state of sodium fast reactor technologies. Five independent gap analyses were performed resulting in the following topical reports: (1) Accident Initiators and Sequences (i.e., Initiators/Sequences Technology Gap Analysis), (2) Sodium Technology Phenomena (i.e., Advanced Burner Reactor Sodium Technology Gap Analysis), (3) Fuels and Materials (i.e., Sodium Fast Reactor Fuels and Materials: Research Needs), (4) Source Term Characterization (i.e., Advanced Sodium Fast Reactor Accident Source Terms: Research Needs), and (5) Computer Codes and Models (i.e., Sodium Fast Reactor Gaps Analysis of Computer Codes and Models for Accident Analysis and Reactor Safety). Volume II of the Sodium Research Plan consolidates the five gap analysis reports produced by each expert panel, wherein the importance of the identified phenomena and necessities of further experimental research and code development were addressed. The findings from these five reports comprised the basis for the analysis in Sodium Fast Reactor Research Plan Volume I.

  5. Technology in Note Taking and Assessment: The Effects of Congruence on Student Performance

    Directory of Open Access Journals (Sweden)

    Matthew E. Barrett

    2014-01-01

    Full Text Available This study examined the encoding specificity principle in relation to traditional and computer-based note taking and assessment formats in higher education. Students (N = 79 took lecture notes either by hand (n = 40 or by computer (n = 39 and then completed either a computer or a paper-based assessment. When note taking and assessment formats were congruent, students scored significantly higher on the assessment when compared to students whose note taking and assessment format were incongruent. These findings highlight the importance of research on how in-class technology may affect student performance, and suggest that faculty and administrators seek to coordinate and standardize the use of assessment and note taking technologies where possible.

  6. Correlation of Objective Assessment Data With General Surgery Resident In-Training Evaluation Reports and Operative Volumes.

    Science.gov (United States)

    Abdelsattar, Jad M; AlJamal, Yazan N; Ruparel, Raaj K; Rowse, Phillip G; Heller, Stephanie F; Farley, David R

    2018-05-14

    Faculty evaluations, ABSITE scores, and operative case volumes often tell little about true resident performance. We developed an objective structured clinical examination called the Surgical X-Games (5 rooms, 15 minutes each, 12-15 tests total, different for each postgraduate [PGY] level). We hypothesized that performance in X-Games will prove more useful in identifying areas of strength or weakness among general surgery (GS) residents than faculty evaluations, ABSITE scores, or operative cases volumes. PGY 2 to 5 GS residents (n = 35) were tested in a semiannual X-Games assessment using multiple simulation tasks: laparoscopic skills, bowel anastomosis, CT/CXR analysis, chest tube placement, etc. over 1 academic year. Resident scores were compared to their ABSITE, in-training evaluation reports, and operating room case numbers. Academic medical center. PGY-2, 3, 4, and 5 GS residents at Mayo Clinic in Rochester, MN. Results varied greatly within each class except for staff evaluations: in-training evaluation reports medians for PGY-2s were 5.3 (range: 5.0-6.0), PGY-3s 5.9 (5.5-6.3), PGY-4s 5.6 (5.0-6.0), and PGY-5s were 6.1 (5.6-6.9). Although ABSITE and operating room case volumes fluctated greatly with each PGY class, only X-Games scores (median: PGY-2 = 82, PGY-3 = 61, PGY-4 = 76, and PGY-5 = 60) correlated positively (p < 0.05) with operative case volume and negatively (p < 0.05) with staff evaluations. X-Games assessment generated wide differentiation of resident performance quickly, inexpensively, and objectively. Although "Minnesota-nice" surgical staff may feel all GS trainees are "above average," objective assessment tells us otherwise. Copyright © 2018 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  7. 78 FR 49287 - Environmental Assessment for Potential Lease Issuance and Marine Hydrokinetic Technology Testing...

    Science.gov (United States)

    2013-08-13

    ...; MMAA104000] Environmental Assessment for Potential Lease Issuance and Marine Hydrokinetic Technology Testing... important environmental issues associated with data collection and technology testing activities (76 FR... Availability of a Revised Environmental Assessment and a Finding of No Significant Impact. SUMMARY: BOEM has...

  8. Life cycle assessment of products and technologies. LCA Symposium

    Energy Technology Data Exchange (ETDEWEB)

    Koukkari, H.; Nors, M. (eds.)

    2009-12-15

    VTT Technical Research Centre of Finland organised a Symposium 'Life Cycle Assessment of Products and Technologies' on the 6th of October, 2009. The Symposium gave a good overview of methods, tools and applications of Life Cycle Assessment developed and utilised in several technology fields of VTT. The 12 Symposium papers deal with recent LCA studies on products and technologies. The scope ranges from beverage cups to urban planning, from inventory databases to rating systems. Topical issues relating to climate change concern biorefineries and the overall impacts of the utilisation of biomass. The calculation of carbon footprints is also introduced through paper products and magazines. One example of LCA tools developed at VTT addresses cement manufacturing. VTT's transport emission database, LIPASTO, was introduced in detail. The use of LCA methods and life cycle thinking is described in various contexts: product development in relation to precision instruments; selection of materials and work processes in relation to sediment remediation project; and procedures of sustainability rating through VTT's office building Digitalo. The Climate Bonus project presented a demonstrated ICT support that informs about the greenhouse gas emissions and carbon footprints of households. (orig.)

  9. A systematic assessment of the state of hazardous waste clean-up technologies

    International Nuclear Information System (INIS)

    Berg, M.T.; Reed, B.E.; Gabr, M.

    1993-07-01

    West Virginia University (WVU) and the US DOE Morgantown Energy Technology Center (METC) entered into a Cooperative Agreement on August 29, 1992 entitled ''Decontamination Systems Information and Research Programs.'' Stipulated within the Agreement is the requirement that WVU submit to METC a series of Technical Progress Report for Year 1 of the Agreement. This report reflects the progress and/or efforts performed on the following nine technical projects encompassed by the Year 1 Agreement for the period of April 1 through June 30, 1993: Systematic assessment of the state of hazardous waste clean-up technologies; site remediation technologies -- drain-enhanced soil flushing (DESF) for organic contaminants removal; site remediation technologies -- in situ bioremediation of organic contaminants; excavation systems for hazardous waste sites; chemical destruction of polychlorinated biphenyls; development of organic sensors -- monolayer and multilayer self-assembled films for chemical sensors; Winfield lock and dam remediation; Assessments of Technologies for hazardous waste site remediation -- non-treatment technologies and pilot scale test facility implementation; and remediation of hazardous sites with stream reforming

  10. QUALITY OF HEALTH TECHNOLOGY ASSESSMENT REPORTS PREPARED FOR THE MEDICAL SERVICES ADVISORY COMMITTEE.

    Science.gov (United States)

    Hua, Martin; Boonstra, Tristan; Kelly, Patrick J; Wilson, Andrew; Craig, Jonathan C; Webster, Angela C

    2016-01-01

    The Medical Services Advisory Committee (MSAC) makes recommendations to the Australian Government for funding health technologies under the Medicare Benefits Schedule (MBS). Differences in public, clinical, commercial, and political opinions on health expenditure emphasize the importance of defensible funding decisions. We aimed to evaluate the quality of health technology assessment (HTA) reports over time and among health technologies assessed for MSAC. A cohort study was performed of HTA reports prepared for MSAC between 1998 and 2013. We measured the quality of HTA reports using reporting guidelines proposed by the European Collaboration for Assessment of Health Interventions. Individual component scores across eleven domains were calculated, and summed for an overall aggregate score. We used linear regression to investigate any change in quality over time and among the types of technologies assessed. We included 110 HTA reports. The safety (80 percent), effectiveness (84 percent), economic (74 percent), and organizational (99 percent) domains were better reported than the psychological, social, and ethical considerations (34 percent). The basic (75 percent), methodological (62 percent), background (82 percent), contextual (46 percent), status quo (54 percent), and technical information (66 percent) that framed each assessment were inconsistently reported. On average, overall quality scores increased by 2 percent (p technologies (p = 0.22). HTA reports prepared for MSAC are a key tool in allocating scarce health resources. The overall quality of these reports has improved, but the reporting of specific domains and subthemes therein could be better addressed.

  11. Assessment of foreign decommissioning technology with potential application to US decommissioning needs

    International Nuclear Information System (INIS)

    Allen, R.P.; Konzek, G.J.; Schneider, K.J.; Smith, R.I.

    1987-09-01

    This study was conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE) to identify and technically assess foreign decommissioning technology developments that may represent significant improvements over decommissioning technology currently available or under development in the United States. Technology need areas for nuclear power reactor decommissioning operations were identified and prioritized using the results of past light water reactor (LWR) decommissioning studies to quantitatively evaluate the potential for reducing cost and decommissioning worker radiation dose for each major decommissioning activity. Based on these identified needs, current foreign decommissioning technologies of potential interest to the US were identified through personal contacts and the collection and review of an extensive body of decommissioning literature. These technologies were then assessed qualitatively to evaluate their uniqueness, potential for a significant reduction in decommissioning costs and/or worker radiation dose, development status, and other factors affecting their value and applicability to US needs

  12. Assessment of new radiation oncology technology and treatments in radiation oncology the ANROTAT project and collection of IMRT specific data

    International Nuclear Information System (INIS)

    Haworth, A.; Corry, J.; Kron, T.; Duchesne, G.; Ng, M.; Burmeister, B.

    2010-01-01

    Full text: Medical physicists (MP) are familiar with assessing new radiation oncology technology and treatments ( ROT A T) for their own departments but are not usually involved in providing advice to government for funding these technologies. This paper describes the role of the MP within the Commonwealth Government Department of Health and Aging initiative to develop a generic framework for assessment of ROTAT and the collection of data to support Med care Benefits Scheme (MBS) funding of IMRT. The clinical trials group TROG is developing a generic framework for the assessment of NROTAT. This will be tested and data collected to support applications for MBS funding of IMRT and IGRT. The tumour sites of nasopharynx, post-prostatectomy and anal canal have been selected to represent sites that are commonly, occasionally and rarely treated with IMRT respectively. Site selection for data collection will represent a broad range of clinical practices. Data quality is assured through TROG QA procedures and will include dosimetry audits. The final report will assess the clinical efficacy, cost effectiveness and safety of IMRT compared to 3DCRT. Existing clinical trial protocols form the basis for data collection and surrogate endpoints are being developed. Key publications have been identified that correlate specific dose-volume histogram parameters with clinical end-points, recognising limitations of these data in the 1MRT setting. Engagement of MPs within this project will help ensure collection of high quality data that ultimately aims to secure appropriate funding to ensure our patients receive best clinical care. (author)

  13. Skeletal and total body volumes of human fetuses: assessment of reference data by spiral CT

    International Nuclear Information System (INIS)

    Braillon, Pierre M.; Buenerd, Annie; Bouvier, Raymonde; Lapillonne, Alexandre

    2002-01-01

    Objective: To define reference data for skeletal and total body volumes of normal human fetuses. Materials and methods: Spiral CT was used to assess the skeletal and total body volumes of 31 normal human stillborn infants with gestational age (GA) and body weight (BW) ranging from 14 to 41.5 weeks and 22 to 3,760 g, respectively. CT scans (slice thickness 2.7 mm, pitch 0.7) were performed within the first 24 h after delivery. Precise bone and soft-tissue windows were defined from analysis of the density along the diaphysis of the fetal long bones and from the measurement of a phantom that mimics soft tissues. Lengths and volumes were obtained from 3D reconstructions. The femur lengths measured from CT images (FLct) were compared with those provided by US studies (FLus). Results: Significant correlations (r>0.9) were found between BW, measured volumes of the entire skeleton or head, long-bone lengths, biparietal diameter and GA. Strong linear correlations (r>0.98) were observed between FLct and FLus. Conclusions: Skeletal and total body volume values obtained using spiral CT were significantly correlated with fetal biometric measurements. These data could complement those obtained in obstetric investigations with US. (orig.)

  14. Alternative Assessment Methods Based on Categorizations, Supporting Technologies, and a Model for Betterment

    Science.gov (United States)

    Ben-Jacob, Marion G.; Ben-Jacob, Tyler E.

    2014-01-01

    This paper explores alternative assessment methods from the perspective of categorizations. It addresses the technologies that support assessment. It discusses initial, formative, and summative assessment, as well as objective and subjective assessment, and formal and informal assessment. It approaches each category of assessment from the…

  15. Sludge technology assessment

    International Nuclear Information System (INIS)

    Krause, T.R.; Cunnane, J.C.; Helt, J.E.

    1994-12-01

    The retrieval, processing, and generation of final waste forms from radioactive tank waste sludges present some of the most challenging technical problems confronting scientists and engineers responsible for the waste management programs at the various Department of Energy laboratories and production facilities. Currently, the Department of Energy is developing a strategy to retrieve, process, and generate a final waste form for the sludge that meets the acceptance criteria for the final disposition. An integral part of this strategy will be use of separation processes that treat the sludge; the goal is to meet feed criteria for the various processes that will generate the final waste form, such as vitrification or grouting. This document is intended to (1) identify separation technologies which are being considered for sludge treatment at various DOE sites, (2) define the current state of sludge treatment technology, (3) identify what research and development is required, (4) identify current research programs within either DOE or academia developing sludge treatment technology, and (5) identify commercial separation technologies which may be applicable. Due to the limited scope of this document, technical evaluations regarding the need for a particular separations technology, the current state of development, or the research required for implementation, are not provided

  16. Hybrid life cycle assessment comparison of colloidal silica and cement grouted soil barrier remediation technologies.

    Science.gov (United States)

    Gallagher, Patricia M; Spatari, Sabrina; Cucura, Jeffrey

    2013-04-15

    Site remediation involves balancing numerous costs and benefits but often neglects the environmental impacts over the entire project life cycle. Life cycle assessment (LCA) offers a framework for inclusion of global environmental "systems-level" decision metrics in combination with technological and cost analysis. We compare colloidal silica (CS) and cement grouted soil barrier remediation technologies for soils affected by low level radionuclides at a U.S. Superfund site using hybrid LCA methods. CS is a new, high performance grouting material installed using permeation grouting techniques. Cement, a more traditional grouting material, is typically installed using jet grouting techniques. Life cycle impacts were evaluated using the US EPA TRACI 2 model. Results show the highest life cycle environmental impacts for the CS barrier occur during materials production and transportation to the site. In general, the life cycle impacts for the cement barrier were dominated by materials production; however, in the extreme scenario the life cycle impacts were dominated by truck transportation of spoils to a distant, off-site radioactive waste facility. It is only in the extreme scenario tested in which soils are transported by truck (Option 2) that spoils waste transport dominates LCIA results. Life cycle environmental impacts for both grout barriers were most sensitive to resource input requirements for manufacturing volumes and transportation. Uncertainty associated with the efficacy of new technology such as CS over its required design life indicates that barrier replacement could increase its life cycle environmental impact above that of the cement barrier. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. The responsibility of technology. Weighting goods - risk assessment - codes of conduct

    International Nuclear Information System (INIS)

    Lenk, H.; Maring, M.

    1991-01-01

    Under the heading 'The responsibility of technology' nineteen authors contribute to the following topics: Basic questions of weighting 'goods' relating to resources, the relationship of technical possibilities and (self)restraint of individuals and collectives, striving for knowledge and appropriate limits, possibilities of directing and influencing technology and questions concerning (the limits of) individual and collective responsibility. Dealt with in more detail are: The assessment of technical risks and uncertainties from an ethical and legal point of view, problems in nuclear research and technology illustrated by the example of Chernobyl, information technology, and the influence of the press when presenting technology matters. (orig./HSCH) [de

  18. [Meta-analyses on measurement precision of non-invasive hemodynamic monitoring technologies in adults].

    Science.gov (United States)

    Pestel, G; Fukui, K; Higashi, M; Schmidtmann, I; Werner, C

    2018-06-01

    An ideal non-invasive monitoring system should provide accurate and reproducible measurements of clinically relevant variables that enables clinicians to guide therapy accordingly. The monitor should be rapid, easy to use, readily available at the bedside, operator-independent, cost-effective and should have a minimal risk and side effect profile for patients. An example is the introduction of pulse oximetry, which has become established for non-invasive monitoring of oxygenation worldwide. A corresponding non-invasive monitoring of hemodynamics and perfusion could optimize the anesthesiological treatment to the needs in individual cases. In recent years several non-invasive technologies to monitor hemodynamics in the perioperative setting have been introduced: suprasternal Doppler ultrasound, modified windkessel function, pulse wave transit time, radial artery tonometry, thoracic bioimpedance, endotracheal bioimpedance, bioreactance, and partial CO 2 rebreathing have been tested for monitoring cardiac output or stroke volume. The photoelectric finger blood volume clamp technique and respiratory variation of the plethysmography curve have been assessed for monitoring fluid responsiveness. In this manuscript meta-analyses of non-invasive monitoring technologies were performed when non-invasive monitoring technology and reference technology were comparable. The primary evaluation criterion for all studies screened was a Bland-Altman analysis. Experimental and pediatric studies were excluded, as were all studies without a non-invasive monitoring technique or studies without evaluation of cardiac output/stroke volume or fluid responsiveness. Most studies found an acceptable bias with wide limits of agreement. Thus, most non-invasive hemodynamic monitoring technologies cannot be considered to be equivalent to the respective reference method. Studies testing the impact of non-invasive hemodynamic monitoring technologies as a trend evaluation on outcome, as well as

  19. Assessment of early bronchiectasis in young children with cystic fibrosis is dependent on lung volume

    NARCIS (Netherlands)

    M.P.L. Bard (Martin); K. Graniel (Karla); J. Park (Judy); N.H. de Klerk (Nicholas); P.D. Sly; C.P. Murray (Conor); H.A.W.M. Tiddens (Harm); S. Stick

    2013-01-01

    textabstractObjective: The aim of this study was to determine whether assessment of early CT scan-detected bronchiectasis in young children with cystic fibrosis (CF) depends on lung volume. Methods: This study, approved by the hospital ethics committee, included 40 young children with CF from a

  20. Hybrid life cycle assessment comparison of colloidal silica and cement grouted soil barrier remediation technologies

    Energy Technology Data Exchange (ETDEWEB)

    Gallagher, Patricia M., E-mail: pmg24@drexel.edu [Civil, Architectural and Environmental Engineering, Drexel University, 3141 Chestnut Street, Philadelphia, PA 19038 (United States); Spatari, Sabrina; Cucura, Jeffrey [Civil, Architectural and Environmental Engineering, Drexel University, 3141 Chestnut Street, Philadelphia, PA 19038 (United States)

    2013-04-15

    Highlights: ► We use LCA to study environmental impacts of grouting techniques for site remediation. ► We consider colloidal silica permeation grouting and cement jet grouting. ► Manufacturing and transportation contribute significantly in all impact categories. ► Activity outside of direct site activity is important in assessing impacts. ► LCA can be used to consider sustainability criteria for remediation decisions. -- Abstract: Site remediation involves balancing numerous costs and benefits but often neglects the environmental impacts over the entire project life cycle. Life cycle assessment (LCA) offers a framework for inclusion of global environmental “systems-level” decision metrics in combination with technological and cost analysis. We compare colloidal silica (CS) and cement grouted soil barrier remediation technologies for soils affected by low level radionuclides at a U.S. Superfund site using hybrid LCA methods. CS is a new, high performance grouting material installed using permeation grouting techniques. Cement, a more traditional grouting material, is typically installed using jet grouting techniques. Life cycle impacts were evaluated using the US EPA TRACI 2 model. Results show the highest life cycle environmental impacts for the CS barrier occur during materials production and transportation to the site. In general, the life cycle impacts for the cement barrier were dominated by materials production; however, in the extreme scenario the life cycle impacts were dominated by truck transportation of spoils to a distant, off-site radioactive waste facility. It is only in the extreme scenario tested in which soils are transported by truck (Option 2) that spoils waste transport dominates LCIA results. Life cycle environmental impacts for both grout barriers were most sensitive to resource input requirements for manufacturing volumes and transportation. Uncertainty associated with the efficacy of new technology such as CS over its required