  1. Federal Technology Alert: Ground-Source Heat Pumps Applied to Federal Facilities-Second Edition; FINAL

    International Nuclear Information System (INIS)

    Hadley, Donald L

    2001-01-01

    This Federal Technology Alert, which was sponsored by the U.S. Department of Energy's Office of Federal Energy Management Programs, provides the detailed information and procedures that a Federal energy manager needs to evaluate most ground-source heat pump applications. This report updates an earlier report on ground-source heat pumps that was published in September 1995. In the current report, general benefits of this technology to the Federal sector are described, as are ground-source heat pump operation, system types, design variations, energy savings, and other benefits. In addition, information on current manufacturers, technology users, and references for further reading are provided

  2. Strategic GHG reduction through the use of ground source heat pump technology

    International Nuclear Information System (INIS)

    Hanova, J; Dowlatabadi, H

    2007-01-01

    Higher energy prices and concern about climate change is drawing increasing attention to ground source heat pump (GSHP) systems. Their clear advantage lies in being able to provide heating using 25 to 30% of the energy consumed by even the most efficient conventional alternatives. Their drawback has been high capital costs and uncertainty about whether the emissions associated with the electric power used to energise the system has higher system-wide emissions than the highest-efficiency furnaces. This study delineates circumstances under which GSHP systems achieve net emission reductions, for different electricity generation methods, heat pump efficiencies, and heating loads. We illustrate the effect of relative fuel prices on annual operating savings using fuel prices in multiple countries. Annual operating savings determine how rapidly the technology achieves payback and then generates return on the initial capital investment. Finally, we highlight the least cost supply curve for using GSHP to reduce greenhouse gas emissions. Using the United States as a base reference case, this study explores the potential of GSHP in cold-climate countries worldwide

  3. Responder Technology Alert (February 2015)

    Energy Technology Data Exchange (ETDEWEB)

    Upton, Jaki F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Stein, Steven L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-04-10

    As part of technology foraging for the Responder Technology Alliance, established by the Department of Homeland Science and Technologies First Responders Group, this report summarizes technologies that are relevant in the area of “wearables,” with the potential for use by first responders. The content was collected over the previous month(s) and reproduced from a general Internet search using the term wearables. Additional information is available at the websites provided. This report is not meant to be an exhaustive list nor an endorsement of any technology described herein. Rather, it is meant to provide useful information about current developments in the areas wearable technology.

  4. Responder Technology Alert Monthly (January 2015)

    Energy Technology Data Exchange (ETDEWEB)

    Upton, Jaki F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Stein, Steven L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-02-01

    As part of technology foraging for the Responder Technology Alliance, established by the Department of Homeland Science and Technologies First Responders Group, this report summarizes technologies that are relevant in the area of “wearables,” with the potential for use by first responders. The content was collected over the previous month(s) and reproduced from a general Internet search using the term wearables. Additional information is available at the websites provided. This report is not meant to be an exhaustive list nor an endorsement of any technology described herein. Rather, it is meant to provide useful information about current developments in the areas wearable technology.

  5. Responder Technology Alert Monthly (December 2014)

    Energy Technology Data Exchange (ETDEWEB)

    Upton, Jaki F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Stein, Steven L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-02-13

    As part of technology foraging for the Responder Technology Alliance, established by the Department of Homeland Science and Technologies First Responders Group, this report summarizes technologies that are relevant in the area of “wearables,” with the potential for use by first responders. The content was collected over the previous month(s) and reproduced from a general Internet search using the term wearables. Additional information is available at the websites provided. This report is not meant to be an exhaustive list nor an endorsement of any technology described herein. Rather, it is meant to provide useful information about current developments in the areas wearable technology.

  6. Thermal Energy for Space Cooling--Federal Technology Alert

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Daryl R.

    2000-12-31

    Cool storage technology can be used to significantly reduce energy costs by allowing energy-intensive, electrically driven cooling equipment to be predominantly operated during off peak hours when electricity rates are lower. This Federal Technology Alert, which is sponsored by DOE's Federal Energy Management Program (FEMP), describes the basic types of cool storage technologies and cooling system integration options. In addition, it defines the savings potential in the federal sector, presents application advice, and describes the performance experience of specific federal users. The results of a case study of a GSA building using cool storage technology are also provided.

  7. Green Roofs: Federal Energy Management Program (FEMP) Federal Technology Alert

    Energy Technology Data Exchange (ETDEWEB)

    Scholz-Barth, K.; Tanner, S.

    2004-09-01

    In a ''green roof,'' a layer of vegetation (e.g., a roof garden) covers the surface of a roof to provide shade, cooler indoor and outdoor temperatures, and effective storm-water management to reduce runoff. The main components are waterproofing, soil, and plants. There are two basic kinds: intensive and extensive. An intensive green roof often features large shrubs and trees, and it can be expensive to install and maintain. An extensive green roof features shallow soil and low-growing, horizontally spreading plants that can thrive in the alpine conditions of many rooftops. These plants do not require a lot of water or soil, and they can tolerate a significant amount of exposure to the sun and wind. This Federal Technology Alert focuses on the benefits, design, and implementation of extensive green roofs and includes criteria for their use on federal facilities.

  8. Federal technology alert. Parabolic-trough solar water heating

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-04-01

    Parabolic-trough solar water heating is a well-proven renewable energy technology with considerable potential for application at Federal facilities. For the US, parabolic-trough water-heating systems are most cost effective in the Southwest where direct solar radiation is high. Jails, hospitals, barracks, and other facilities that consistently use large volumes of hot water are particularly good candidates, as are facilities with central plants for district heating. As with any renewable energy or energy efficiency technology requiring significant initial capital investment, the primary condition that will make a parabolic-trough system economically viable is if it is replacing expensive conventional water heating. In combination with absorption cooling systems, parabolic-trough collectors can also be used for air-conditioning. Industrial Solar Technology (IST) of Golden, Colorado, is the sole current manufacturer of parabolic-trough solar water heating systems. IST has an Indefinite Delivery/Indefinite Quantity (IDIQ) contract with the Federal Energy Management Program (FEMP) of the US Department of Energy (DOE) to finance and install parabolic-trough solar water heating on an Energy Savings Performance Contract (ESPC) basis for any Federal facility that requests it and for which it proves viable. For an ESPC project, the facility does not pay for design, capital equipment, or installation. Instead, it pays only for guaranteed energy savings. Preparing and implementing delivery or task orders against the IDIQ is much simpler than the standard procurement process. This Federal Technology Alert (FTA) of the New Technology Demonstration Program is one of a series of guides to renewable energy and new energy-efficient technologies.

  9. Bar Code Medication Administration Technology: Characterization of High-Alert Medication Triggers and Clinician Workarounds.

    Science.gov (United States)

    Miller, Daniel F; Fortier, Christopher R; Garrison, Kelli L

    2011-02-01

    Bar code medication administration (BCMA) technology is gaining acceptance for its ability to prevent medication administration errors. However, studies suggest that improper use of BCMA technology can yield unsatisfactory error prevention and introduction of new potential medication errors. To evaluate the incidence of high-alert medication BCMA triggers and alert types and discuss the type of nursing and pharmacy workarounds occurring with the use of BCMA technology and the electronic medication administration record (eMAR). Medication scanning and override reports from January 1, 2008, through November 30, 2008, for all adult medical/surgical units were retrospectively evaluated for high-alert medication system triggers, alert types, and override reason documentation. An observational study of nursing workarounds on an adult medicine step-down unit was performed and an analysis of potential pharmacy workarounds affecting BCMA and the eMAR was also conducted. Seventeen percent of scanned medications triggered an error alert of which 55% were for high-alert medications. Insulin aspart, NPH insulin, hydromorphone, potassium chloride, and morphine were the top 5 high-alert medications that generated alert messages. Clinician override reasons for alerts were documented in only 23% of administrations. Observational studies assessing for nursing workarounds revealed a median of 3 clinician workarounds per administration. Specific nursing workarounds included a failure to scan medications/patient armband and scanning the bar code once the dosage has been removed from the unit-dose packaging. Analysis of pharmacy order entry process workarounds revealed the potential for missed doses, duplicate doses, and doses being scheduled at the wrong time. BCMA has the potential to prevent high-alert medication errors by alerting clinicians through alert messages. Nursing and pharmacy workarounds can limit the recognition of optimal safety outcomes and therefore workflow processes

  10. Responder Technology Alert Monthly (Oct-Nov 2014)

    Energy Technology Data Exchange (ETDEWEB)

    Upton, Jaki F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Stein, Steven L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-01-21

    As part of technology foraging for the Responder Technology Alliance, established by the Department of Homeland Science and Technologies First Responders Group, this report summarizes technologies that are relevant in the area of “wearables,” with the potential for use by first responders. The content was collected over the previous month(s) and reproduced from a general Internet search using the term wearables. Additional information is available at the websites provided. This report is not meant to be an exhaustive list nor an endorsement of any technology described herein. Rather, it is meant to provide useful information about current developments in the areas wearable technology.

  11. Optimal Ground Source Heat Pump System Design

    Energy Technology Data Exchange (ETDEWEB)

    Ozbek, Metin [Environ Holdings Inc., Princeton, NJ (United States); Yavuzturk, Cy [Univ. of Hartford, West Hartford, CT (United States); Pinder, George [Univ. of Vermont, Burlington, VT (United States)

    2015-04-01

    Despite the facts that GSHPs first gained popularity as early as the 1940’s and they can achieve 30 to 60 percent in energy savings and carbon emission reductions relative to conventional HVAC systems, the use of geothermal energy in the U.S. has been less than 1 percent of the total energy consumption. The key barriers preventing this technically-mature technology from reaching its full commercial potential have been its high installation cost and limited consumer knowledge and trust in GSHP systems to deliver the technology in a cost-effective manner in the market place. Led by ENVIRON, with support from University Hartford and University of Vermont, the team developed and tested a software-based a decision making tool (‘OptGSHP’) for the least-cost design of ground-source heat pump (‘GSHP’) systems. OptGSHP combines state of the art optimization algorithms with GSHP-specific HVAC and groundwater flow and heat transport simulation. The particular strength of OptGSHP is in integrating heat transport due to groundwater flow into the design, which most of the GSHP designs do not get credit for and therefore are overdesigned.

  12. A case study of pediatric asthma alerts from the beacon community program in cincinnati: technology is just the first step.

    Science.gov (United States)

    Trudnak, Tara; Mansour, Mona; Mandel, Keith; Sauers, Hadley; Pandzik, Gerry; Donisi, Carl; Fairbrother, Gerry

    2014-01-01

    The Beacon Community in Cincinnati, Ohio was an innovative, community-wide initiative to use technology to transform care. One important feature was the development of regional alerts to notify practices when patients were hospitalized or seen in the emergency department. The purpose of this paper is to describe the way in which technology engages the improvement process, and to describe the early stages of learning how to use technology to enhance quality improvement. We interviewed key Beacon leaders as well as providers and office staff in selected practices. We also collected preliminary data from practices that reflected handling of alerts, including the number of asthma related alerts received and followed up. Regional alerts, supplied by the community-wide health information exchange, were a significant addition to the quality improvement effort in that they enabled practices to identify and follow up with additional children at risk. An important finding was the substantial effort at the practice level to integrate technology into ongoing patient care. Developing the technology for community wide alerts represented a significant endeavor in the Cincinnati Beacon Community. However, the technology was just the first step. Despite extra effort and time required on the part of individual practices, they reported that the value of having alerts was high. Hospital and ED visits represent some of the most costly aspects of care, and an efficient process for intervening with children using these costly services was seen as of significant value.

  13. Ground Source Geothermal District Heating and Cooling System

    Energy Technology Data Exchange (ETDEWEB)

    Lowe, James William [Ball State Univ., Muncie, IN (United States)

    2016-10-21

    Ball State University converted its campus from a coal-fired steam boiler district heating system to a ground source heat pump geothermal district system that produces simultaneously hot water for heating and chilled water for cooling. This system will include the installation of 3,600 four hundred feet deep vertical closed loop boreholes making it the largest ground source geothermal district system in the country. The boreholes will act as heat exchangers and transfer heat by virtue of the earth’s ability to maintain an average temperature of 55 degree Fahrenheit. With growing international concern for global warming and the need to reduce worldwide carbon dioxide loading of the atmosphere geothermal is poised to provide the means to help reduce carbon dioxide emissions. The shift from burning coal to utilizing ground source geothermal will increase electrical consumption but an overall decrease in energy use and reduction in carbon dioxide output will be achieved. This achievement is a result of coupling the ground source geothermal boreholes with large heat pump chiller technology. The system provides the thermodynamic means to move large amounts of energy with limited energy input. Ball State University: http://cms.bsu.edu/About/Geothermal.aspx

  14. Current status of ground-source heat pumps in China

    International Nuclear Information System (INIS)

    Yang Wei; Zhou Jin; Xu Wei; Zhang Guoqiang

    2010-01-01

    As a renewable energy technology, the ground-source heat pump (GSHP) technologies have increasingly attracted world-wide attention due to their advantages of energy efficiency and environmental friendliness. This paper presents Chinese research and application on GSHP followed by descriptions of patents. The policies related to GSHP are also introduced and analyzed. With the support of Chinese government, several new heat transfer models and two new GSHP systems (named pumping and recharging well (PRW) and integrated soil cold storage and ground-source heat pump (ISCS and GSHP) system) have been developed by Chinese researchers. The applications of GSHP systems have been growing rapidly since the beginning of the 21st century with financial incentives and supportive government policies. However, there are still several challenges for the application of GSHP systems in large scale. This paper raises relevant suggestions for overcoming the existing and potential obstacles. In addition, the developing and applying prospects of GSHP systems in China are also discussed.

  15. 太阳能—地源热泵联合循环技术研究%Study on Technologies of Solar Energy and Ground Source Heat Pump Combined Circulation

    Institute of Scientific and Technical Information of China (English)

    孙洲阳; 陈武

    2011-01-01

    太阳能—地源热泵系统联合循环的研究目前还没有形成完备的理论体系,可供应用的基础数据不足,还不能为工程实际应用提供充足的理论依据.本文就太阳能与地源热泵系统联合运行的必要性和可行性进行探讨,提出了相应的技术方案;总结太阳能—地源热泵空调系统的特性,提出太阳能—地源热泵空调系统有待解决的问题,为太阳能—地源热泵联合循环技术在建筑上应用提供参考和借鉴.%Theory system of solar energy combined with ground-source heat pump has not been mature, thereby lack basic data and theory thereunder for engineering application. Necessarity and feasibility of solar energy combined with ground-source heat pump is discussed, bring forward corresponding technique scheme. Character of solar energy combined with ground-source heat pump system is summarized, and bring forward await settle problems, provide reference for architecture application of solar energy combined with ground-source heat pump.

  16. Ground-source heat pump barometer

    International Nuclear Information System (INIS)

    Anon.

    2011-01-01

    In Europe the ground-source heat pump market contracted for the second year running by 2.9% between 2009 and 2010. Around 103.000 units were sold in 2010, taking the number of installed units over one million. The 3 European countries with the most sales are Sweden (31953 units, +16%), Germany (25516 units, -13%) and France (12250 units, -21%). The drop in sales is generally due to market contraction on the current recession but some specificities exist: for instance the insufficient training of the installers has led to under-performance and to a bad image of this energy in France. The Swedish and German manufacturers are in a very strong position and are increasing their market share in the main European markets. (A.C.)

  17. Ground-source heat pump case studies and utility programs

    Energy Technology Data Exchange (ETDEWEB)

    Lienau, P.J.; Boyd, T.L.; Rogers, R.L.

    1995-04-01

    Ground-source heat pump systems are one of the promising new energy technologies that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to consumers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school and commercial building applications. In order to verify the performance, information was collected for 253 case studies from mainly utilities throughout the United States. The case studies were compiled into a database. The database was organized into general information, system information, ground system information, system performance, and additional information. Information was developed on the status of demand-side management of ground-source heat pump programs for about 60 electric utility and rural electric cooperatives on marketing, incentive programs, barriers to market penetration, number units installed in service area, and benefits.

  18. A novel design method for ground source heat pump

    Directory of Open Access Journals (Sweden)

    Dong Xing-Jie

    2014-01-01

    Full Text Available This paper proposes a novel design method for ground source heat pump. The ground source heat pump operation is controllable by using several parameters, such as the total meters of buried pipe, the space between wells, the thermal properties of soil, thermal resistance of the well, the initial temperature of soil, and annual dynamic load. By studying the effect of well number and well space, we conclude that with the increase of the well number, the inlet and outlet water temperatures decrease in summer and increase in winter, which enhance the efficiency of ground source heat pump. The well space slightly affects the water temperatures, but it affects the soil temperature to some extent. Also the ground source heat pump operations matching with cooling tower are investigated to achieve the thermal balance. This method greatly facilitates ground source heat pump design.

  19. Implementing a national early awareness and alert system for new and emerging health technologies in Italy: the COTE Project.

    Science.gov (United States)

    Migliore, Antonio; Perrini, Maria Rosaria; Jefferson, Tom; Cerbo, Marina

    2012-07-01

    The aim of this study was to establish a national Early Awareness and Alert (EAA) system for the identification and assessment of new and emerging health technologies in Italy. In 2008, Agenas, a public body supporting Regions and the Ministry of Health (MoH) in health services research, started a project named COTE (Observatory of New and Emerging Health Technologies) with the ultimate aim of implementing a national EAA system. The COTE project involved all stakeholders (MoH, Regions, Industry, Universities, technical government bodies, and Scientific Societies), in defining the key characteristics and methods of the EAA system. Agreement with stakeholders was reached using three separate workshops. During the workshops, participants shared and agreed methods for identification of new and emerging health technologies, prioritization, and assessment. The structure of the Horizon Scanning (HS) reports was discussed and defined. The main channels for dissemination of outputs were identified as the EuroScan database, and the stakeholders' Web portals. During the final workshop, Agenas presented the first three HS reports produced at national level and proposed the establishment of a permanent national EAA system. The COTE Project created the basis for a permanent national EAA system in Italy. An infrastructure to enable the stakeholders network to grow was created, methods to submit new and emerging health technologies for possible evaluation were established, methods for assessment of the technologies selected were defined, and the stakeholders involvement was delineated (in the identification, assessment, and dissemination stages).

  20. An analysis of solar assisted ground source heat pumps in cold climates

    International Nuclear Information System (INIS)

    Emmi, Giuseppe; Zarrella, Angelo; De Carli, Michele; Galgaro, Antonio

    2015-01-01

    Highlights: • The work focuses on solar assisted ground source heat pump in cold climates. • Multi-year simulations of SAGSHP, are carried out in six cold locations. • GSHP and SAGSHP are compared. • The effect of total borehole length on the heat pump energy efficiency is studied. • A dedicated control strategy is used to manage both solar and ground loops. - Abstract: Exploiting renewable energy sources for air-conditioning has been extensively investigated over recent years, and many countries have been working to promote the use of renewable energy to decrease energy consumption and CO_2 emissions. Electrical heat pumps currently represent the most promising technology to reduce fossil fuel usage. While ground source heat pumps, which use free heat sources, have been taking significant steps forward and despite the fact that their energy performance is better than that of air source heat pumps, their development has been limited by their high initial investment cost. An alternative solution is one that uses solar thermal collectors coupled with a ground source heat pump in a so-called solar assisted ground source heat pump. A ground source heat pump system, used to heat environments located in a cold climate, was investigated in this study. The solar assisted ground source heat pump extracted heat from the ground by means of borehole heat exchangers and it injected excess solar thermal energy into the ground. Building load profiles are usually heating dominated in cold climates, but when common ground source heat pump systems are used only for heating, their performance decreases due to an unbalanced ground load. Solar thermal collectors can help to ensure that systems installed in cold zones perform more efficiently. Computer simulations using a Transient System Simulation (TRNSYS) tool were carried out in six cold locations in order to investigate solar assisted ground source heat pumps. The effect of the borehole length on the energy efficiency of

  1. Design of anti-theft/cable cut real time alert system for copper cable using microcontroller and GSM technology

    Science.gov (United States)

    Lim, E. K.; Norizan, M. N.; Mohamad, I. S.; Yasin, M. N. M.; Murad, S. A. Z.; Baharum, N. A.; Jamalullail, N.

    2017-09-01

    This paper presents the design of anti-theft/cable cut real time alert system using microcontroller and GSM technology. The detection part is using the electrical circuit wire connection in detecting the voltage drop of the cable inside the microcontroller digital input port. The GSM wireless modem is used to send the location of cable cut directly to the authority mobile phone. Microcontroller SK40C with Microchip PIC16F887 is used as a controller to control the wireless modem and also the detection device. The device is able to detect and display the location of the cable cut on the LCD display besides of and sending out the location of the cable break to the authority mobile phone wirelessly via SMS.

  2. Technological Proficiency as a Key to Job Security. Trends and Issues Alert No. 6.

    Science.gov (United States)

    Imel, Susan

    Although not all current jobs require basic computer skills, technological advances in society have created new jobs and changed the ways many existing jobs are performed. Clearly, workers who are proficient in technology have a greater advantage in the current workplace and the need for technologically proficient workers will only continue to…

  3. North Village Ground Source Heat Pump Demonstration Project

    Energy Technology Data Exchange (ETDEWEB)

    Redderson, Jeff

    2015-08-03

    This project demonstrated the feasibility of converting from a traditional direct exchange system to a ground source heat pump system on a large scale, multiple building apartment complex on a university campus. A total of ten apartment buildings were converted using vertical well fields and a ground source loop that connected the 24 apartments in each building into a common system. The system has yielded significant operational savings in both energy and maintenance and transformed the living environments of these residential buildings for our students.

  4. Machine Learning Technologies Translates Vigilant Surveillance Satellite Big Data into Predictive Alerts for Environmental Stressors

    Science.gov (United States)

    Johnson, S. P.; Rohrer, M. E.

    2017-12-01

    The application of scientific research pertaining to satellite imaging and data processing has facilitated the development of dynamic methodologies and tools that utilize nanosatellites and analytical platforms to address the increasing scope, scale, and intensity of emerging environmental threats to national security. While the use of remotely sensed data to monitor the environment at local and global scales is not a novel proposition, the application of advances in nanosatellites and analytical platforms are capable of overcoming the data availability and accessibility barriers that have historically impeded the timely detection, identification, and monitoring of these stressors. Commercial and university-based applications of these technologies were used to identify and evaluate their capacity as security-motivated environmental monitoring tools. Presently, nanosatellites can provide consumers with 1-meter resolution imaging, frequent revisits, and customizable tasking, allowing users to define an appropriate temporal scale for high resolution data collection that meets their operational needs. Analytical platforms are capable of ingesting increasingly large and diverse volumes of data, delivering complex analyses in the form of interpretation-ready data products and solutions. The synchronous advancement of these technologies creates the capability of analytical platforms to deliver interpretable products from persistently collected high-resolution data that meet varying temporal and geographic scale requirements. In terms of emerging environmental threats, these advances translate into customizable and flexible tools that can respond to and accommodate the evolving nature of environmental stressors. This presentation will demonstrate the capability of nanosatellites and analytical platforms to provide timely, relevant, and actionable information that enables environmental analysts and stakeholders to make informed decisions regarding the prevention

  5. Ground-source heat pump systems in Norway

    International Nuclear Information System (INIS)

    Stene, Joern

    2007-01-01

    The Norwegian ground source heat pump (GSHP) market is reviewed. Boreholes in bedrock are of growing interest for residential systems and of growing interest for larger systems with thermal recharging or thermal energy storage. Ground water is limited to areas where the water has acceptable purity. Challenges and important boundary conditions include 1) high quality GSHP system requires engineering expertise, 2) new building codes and EU directive 'energy performance of buildings.'(2006), and 3) hydronic floor heating systems in 50 percent of new residences (author) (ml)

  6. Case study for ARRA-funded ground-source heat pump (GSHP) demonstration at Oakland University

    Energy Technology Data Exchange (ETDEWEB)

    Im, Piljae [ORNL; Liu, Xiaobing [ORNL

    2015-09-01

    High initial costs and lack of public awareness of ground-source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy-saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects have been competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This paper highlights the findings of a case study of one of the ARRA-funded GSHP demonstration projects, a ground-source variable refrigerant flow (GS-VRF) system installed at the Human Health Building at Oakland University in Rochester, Michigan. This case study is based on the analysis of measured performance data, maintenance records, construction costs, and simulations of the energy consumption of conventional central heating, ventilation, and air-conditioning (HVAC) systems providing the same level of space conditioning as the demonstrated GS-VRF system. The evaluated performance metrics include the energy efficiency of the heat pump equipment and the overall GS-VRF system, pumping performance, energy savings, carbon emission reductions, and cost-effectiveness of the GS-VRF system compared with conventional HVAC systems. This case study also identified opportunities for reducing uncertainties in the performance evaluation, improving the operational efficiency, and reducing the installed cost of similar GSHP systems in the future.

  7. Structure alerts for carcinogenicity, and the Salmonella assay system: a novel insight through the chemical relational databases technology.

    Science.gov (United States)

    Benigni, Romualdo; Bossa, Cecilia

    2008-01-01

    In the past decades, chemical carcinogenicity has been the object of mechanistic studies that have been translated into valuable experimental (e.g., the Salmonella assays system) and theoretical (e.g., compilations of structure alerts for chemical carcinogenicity) models. These findings remain the basis of the science and regulation of mutagens and carcinogens. Recent advances in the organization and treatment of large databases consisting of both biological and chemical information nowadays allows for a much easier and more refined view of data. This paper reviews recent analyses on the predictive performance of various lists of structure alerts, including a new compilation of alerts that combines previous work in an optimized form for computer implementation. The revised compilation is part of the Toxtree 1.50 software (freely available from the European Chemicals Bureau website). The use of structural alerts for the chemical biological profiling of a large database of Salmonella mutagenicity results is also reported. Together with being a repository of the science on the chemical biological interactions at the basis of chemical carcinogenicity, the SAs have a crucial role in practical applications for risk assessment, for: (a) description of sets of chemicals; (b) preliminary hazard characterization; (c) formation of categories for e.g., regulatory purposes; (d) generation of subsets of congeneric chemicals to be analyzed subsequently with QSAR methods; (e) priority setting. An important aspect of SAs as predictive toxicity tools is that they derive directly from mechanistic knowledge. The crucial role of mechanistic knowledge in the process of applying (Q)SAR considerations to risk assessment should be strongly emphasized. Mechanistic knowledge provides a ground for interaction and dialogue between model developers, toxicologists and regulators, and permits the integration of the (Q)SAR results into a wider regulatory framework, where different types of

  8. Advanced control for ground source heat pump systems

    Energy Technology Data Exchange (ETDEWEB)

    Hughes, Patrick [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Gehl, Anthony C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Liu, Xiaobing [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-09-01

    Ground source heat pumps (GSHP), also known as geothermal heat pumps (GHP), are proven advanced HVAC systems that utilize clean and renewable geothermal energy, as well as the massive thermal storage capacity of the ground, to provide space conditioning and water heating for both residential and commercial buildings. GSHPs have higher energy efficiencies than conventional HVAC systems. It is estimated, if GSHPs achieve a 10% market share in the US, in each year, 0.6 Quad Btu primary energy consumption can be saved and 36 million tons carbon emissions can be avoided (Liu et al. 2017). However, the current market share of GSHPs is less than 1%. The foremost barrier preventing wider adoption of GSHPs is their high installation costs. To enable wider adoption of GSHPs, the costeffectiveness of GSHP applications must be improved.

  9. First in situ operation performance test of ground source heat pump in Tunisia

    International Nuclear Information System (INIS)

    Naili, Nabiha; Attar, Issam; Hazami, Majdi; Farhat, Abdelhamid

    2013-01-01

    Highlights: • Evaluate the geothermal energy in Tunisia. • Study of the performance of GSHP system for cooling space. • GSHP is a promising alternative for building cooling in Tunisia. - Abstract: The main purpose of this paper is to study the energetic potential of the deployment in Tunisia of the Ground Source Heat Pump (GSHP) system for cooling mode application. Therefore, a pilot GSHP system using horizontal Ground Heat Exchanger (GHE) was installed and experimented in the Research and Technology Center of Energy (CRTEn), Borj Cédria. The experiment is conducted in a test room with a floor area of about 12 m 2 . In the floor of the tested room is integrated a polyethylene exchanger (PEX) used as a radiant floor cooling (RFC) system. The experimental setup mainly includes the ground temperature, the temperature and flow rate of water circulating in the heat pump and the GHE, as well as the power consumption of the heat pump and circulating pumps. These experimental data are essentially used to evaluate the coefficient of performance of the heat pump (COP hp ) and the overall system (COP sys ) for continuous operation mode. The COP hp and the COP sys were found to be 4.25 and 2.88, respectively. These results reveal that the use of the ground source heat pump is very appropriate for Tunisian building cooling

  10. Ground-Source Heat Pumps. Overview of Market Status, Barriers to Adoption, and Options for Overcoming Barriers

    Energy Technology Data Exchange (ETDEWEB)

    Goetzler, William [Navigant Consulting, Inc., Chicago, IL (United States); Zogg, Robert [Navigant Consulting, Inc., Chicago, IL (United States); Lisle, Heather [Navigant Consulting, Inc., Chicago, IL (United States); Burgos, Javier [Navigant Consulting, Inc., Chicago, IL (United States)

    2009-02-03

    February 2009 final report submitted to DOE by Navigant Consulting, Inc. This report summarizes the status of ground-source heat pump (GSHP) technology and market penetration globally, estimates the energy saving potential of GSHPs in the U.S., identifies key market barriers that are inhibiting wider market adoption of GSHPs, and recommends initiatives that can be implemented or facilitated by the DOE to accelerate market adoption.

  11. Ground source geothermal heat. Ground source heat pumps and underground thermal energy storage systems. Proceedings; Oberflaechennahe Geothermie. Erdgekoppelte Waermepumpen und unterirdische thermische Energiespeicher. Tagungsband

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-07-01

    At the ninth international user forum on shallow geothermal heat on 28th and 29th April, 2009, at BadStaffelstein (Federal Republic of Germany), the following lectures were held: (1) Information system on shallow geothermal heat for Bavaria (Marcellus Schulze); (2) Calculation of the spreading of temperature anomalies in groundwater as an instrument of planning of heat pump systems (Wolfgang Rauch); (3) Comparison of models for simulation of deep geothermal probes (Markus Proell); (4) Impact of the geometry of boreholes and probes on heat transport (Manfred Reuss); (5) Thermal respond tests and temperature depth profiles - Experience from research and practice (Markus Kuebert); (6) A model of simulation for the investigation of the impact of different heat transfer fluids on the efficiency of ground source heat pump devices (Roland Koenigsdorff); (7) The research project EWSplus - Investigations for quality assurance of geothermal probes (Mathieu Riegger); (8) Quality management of plants for the utilization of shallow geothermal heat with geothermal probes - the example of Baden-Wuerttemberg (Bruno Lorinser, Ingrid Stober); (9) Not every heat pump contributes to climate protection (Falk Auer); (10) Field measurements of heat pumps in residential buildings with modern standard and in older buildings (Marek Miara); (11) System technology for a great annual performance factor (Werner Schenk); (12) Modification of older geothermal heat probe devices for use with modern heat pumps (Klaus Friedrich Staerk); (13) Energy-efficient modernisation of a pensioners' condominium from the 1970s with solar-geothermal-air (Michael Guigas); (14) Evaluation and optimization of operation of seasonal storage systems in the foundations of office buildings (Herdis Kipry); (15) Evaluation of an innovative heating and cooling concept with rain water vessels, thermo-active building components and phase change materials in a residential building (Doreen Kalz); (16) Contracts for ground

  12. Alertness management : strategic naps in operational settings

    Science.gov (United States)

    1995-01-01

    Managing fatigue in complex operational settings requires attention to multiple factors, including hours of service, scheduling, education and training, countermeasures, technology, and research. Alertness-management strategies can be used to promote...

  13. Characterization of Site for Installing Open Loop Ground Source Heat Pump System

    Science.gov (United States)

    Yun, S. W.; Park, Y.; Lee, J. Y.; Yi, M. J.; Cha, J. H.

    2014-12-01

    This study was conducted to understand hydrogeological properties of site where open loop ground source heat pump system will be installed and operated. Groundwater level and water temperature were hourly measured at the well developed for usage of open loop ground source heat pump system from 11 October 2013 to 8 January 2014. Groundwater was sampled in January and August 2013 and its chemical and isotopic compositions were analyzed. The bedrock of study area is the Jurassic granodiorite that mainly consists of quartz (27.9 to 46.8%), plagioclase (26.0 to 45.5%), and alkali feldspar (9.5 to 18.7%). The groundwater level ranged from 68.30 to 68.94 m (above mean sea level). Recharge rate was estimated using modified watertable fluctuation method and the recharge ratios was 9.1%. The water temperature ranged from 14.8 to 15.0oC. The vertical Increase rates of water temperature were 1.91 to 1.94/100 m. The water temperature showed the significant seasonal variation above 50 m depth, but had constant value below 50 m depth. Therefore, heat energy of the groundwater can be used securely in open loop ground source heat pump system. Electrical conductivity ranged from 120 to 320 µS/cm in dry season and from 133 to 310 µS/cm in wet season. The electrical conductivity gradually decreased with depth. In particular, electrical conductivity in approximately 30 m depth decreased dramatically (287 to 249 µS/cm) in wet season. The groundwater was Ca-HCO3 type. The concentrations of dissolved components did not show the vertically significant variations from 0 to 250 m depth. The δ18O and δD ranged from -9.5 to -9.4‰ and from -69 to -68‰. This work is supported by the New and Renewable Energy of the Korea Institute of Energy Technology Evaluation and Planning (KETEP) grant funded by the Korea government Ministry of Knowledge Economy (No.20123040110010).

  14. Alert Exchange Process Protocol

    Science.gov (United States)

    Groen, Frank

    2015-01-01

    The National Aeronautics and Space Administration of the United States of America (NASA), and the European Space Agency (ESA), and the Japanese Aerospace Exploration Agency (JAXA), acknowledging that NASA, ESA and JAXA have a mutual interest in exchanging Alerts and Alert Status Lists to enhance the information base for each system participant while fortifying the general level of cooperation between the policy agreement subscribers, and each Party will exchange Alert listings on regular basis and detailed Alert information on a need to know basis to the extent permitted by law.

  15. Ground Source Integrated Heat Pump (GS-IHP) Development

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, V. D. [ORNL; Rice, K. [ORNL; Murphy, R. [ORNL; Munk, J. [ORNL; Ally, Moonis [ORNL; Shen, Bo [ORNL; Craddick, William [ORNL; Hearn, Shawn A. [ClimateMaster, Inc.

    2013-05-24

    Between October 2008 and May 2013 ORNL and ClimateMaster, Inc. (CM) engaged in a Cooperative Research and Development Agreement (CRADA) to develop a groundsource integrated heat pump (GS-IHP) system for the US residential market. A initial prototype was designed and fabricated, lab-tested, and modeled in TRNSYS (SOLAR Energy Laboratory, et al, 2010) to predict annual performance relative to 1) a baseline suite of equipment meeting minimum efficiency standards in effect in 2006 (combination of air-source heat pump (ASHP) and resistance water heater) and 2) a state-of-the-art (SOA) two-capacity ground-source heat pump with desuperheater water heater (WH) option (GSHPwDS). Predicted total annual energy savings, while providing space conditioning and water heating for a 2600 ft{sup 2} (242 m{sup 2}) house at 5 U.S. locations, ranged from 52 to 59%, averaging 55%, relative to the minimum efficiency suite. Predicted energy use for water heating was reduced 68 to 78% relative to resistance WH. Predicted total annual savings for the GSHPwDS relative to the same baseline averaged 22.6% with water heating energy use reduced by 10 to 30% from desuperheater contributions. The 1st generation (or alpha) prototype design for the GS-IHP was finalized in 2010 and field test samples were fabricated for testing by CM and by ORNL. Two of the alpha units were installed in 3700 ft{sup 2} (345 m{sup 2}) houses at the ZEBRAlliance site in Oak Ridge and field tested during 2011. Based on the steady-state performance demonstrated by the GS-IHPs it was projected that it would achieve >52% energy savings relative to the minimum efficiency suite at this specific site. A number of operational issues with the alpha units were identified indicating design changes needed to the system before market introduction could be accomplished. These were communicated to CM throughout the field test period. Based on the alpha unit test results and the diagnostic information coming from the field test

  16. An Experimental Facility to Validate Ground Source Heat Pump Optimisation Models for the Australian Climate

    Directory of Open Access Journals (Sweden)

    Yuanshen Lu

    2017-01-01

    Full Text Available Ground source heat pumps (GSHPs are one of the most widespread forms of geothermal energy technology. They utilise the near-constant temperature of the ground below the frost line to achieve energy-efficiencies two or three times that of conventional air-conditioners, consequently allowing a significant offset in electricity demand for space heating and cooling. Relatively mature GSHP markets are established in Europe and North America. GSHP implementation in Australia, however, is limited, due to high capital price, uncertainties regarding optimum designs for the Australian climate, and limited consumer confidence in the technology. Existing GSHP design standards developed in the Northern Hemisphere are likely to lead to suboptimal performance in Australia where demand might be much more cooling-dominated. There is an urgent need to develop Australia’s own GSHP system optimisation principles on top of the industry standards to provide confidence to bring the GSHP market out of its infancy. To assist in this, the Queensland Geothermal Energy Centre of Excellence (QGECE has commissioned a fully instrumented GSHP experimental facility in Gatton, Australia, as a publically-accessible demonstration of the technology and a platform for systematic studies of GSHPs, including optimisation of design and operations. This paper presents a brief review on current GSHP use in Australia, the technical details of the Gatton GSHP facility, and an analysis on the observed cooling performance of this facility to date.

  17. Energy well. Ground-source heat in one-family houses; Energiakaivo. Maalaemmoen hyoedyntaeminen pientaloissa

    Energy Technology Data Exchange (ETDEWEB)

    Juvonen, J.; Lapinlampi, T.

    2013-08-15

    This guide deals with the legislation, planning, building, usage and maintenance of ground-source heat systems. The guide gives recommendations and instructions on national level on the permit practices and how to carry out the whole ground-source heat system project. The main focus of the guide is on energy wells for one-family houses. The principle is that an action permit is needed to build a ground-source heat system. On ground water areas a permit according to the water act may also be required. To avoid any problems, the placement of the system needs to be planned precisely. This guide gives a comprehension to the orderer on the issues that need to be considered before ordering, during construction, when the system is running and when giving up the use of the ground-source heat system. (orig.)

  18. Physicians’ use of computerized clinical decision supports to improve medication management in the elderly – the Seniors Medication Alert and Review Technology intervention

    Science.gov (United States)

    Alagiakrishnan, Kannayiram; Wilson, Patricia; Sadowski, Cheryl A; Rolfson, Darryl; Ballermann, Mark; Ausford, Allen; Vermeer, Karla; Mohindra, Kunal; Romney, Jacques; Hayward, Robert S

    2016-01-01

    Background Elderly people (aged 65 years or more) are at increased risk of polypharmacy (five or more medications), inappropriate medication use, and associated increased health care costs. The use of clinical decision support (CDS) within an electronic medical record (EMR) could improve medication safety. Methods Participatory action research methods were applied to preproduction design and development and postproduction optimization of an EMR-embedded CDS implementation of the Beers’ Criteria for medication management and the Cockcroft–Gault formula for estimating glomerular filtration rates (GFR). The “Seniors Medication Alert and Review Technologies” (SMART) intervention was used in primary care and geriatrics specialty clinics. Passive (chart messages) and active (order-entry alerts) prompts exposed potentially inappropriate medications, decreased GFR, and the possible need for medication adjustments. Physician reactions were assessed using surveys, EMR simulations, focus groups, and semi-structured interviews. EMR audit data were used to identify eligible patient encounters, the frequency of CDS events, how alerts were managed, and when evidence links were followed. Results Analysis of subjective data revealed that most clinicians agreed that CDS appeared at appropriate times during patient care. Although managing alerts incurred a modest time burden, most also agreed that workflow was not disrupted. Prevalent concerns related to clinician accountability and potential liability. Approximately 36% of eligible encounters triggered at least one SMART alert, with GFR alert, and most frequent medication warnings were with hypnotics and anticholinergics. Approximately 25% of alerts were overridden and ~15% elicited an evidence check. Conclusion While most SMART alerts validated clinician choices, they were received as valuable reminders for evidence-informed care and education. Data from this study may aid other attempts to implement Beers’ Criteria in

  19. Alerts and Advisories

    Science.gov (United States)

    ... in Select Bottles of Muscle Strength and Nighttime Recovery Product Because of Undeclared Milk Allergen on The Label ( FDA 04/06/18 ) Independent Nutrition, Inc Issues Allergy Alert On Undeclared Milk in ...

  20. Medical alert bracelet (image)

    Science.gov (United States)

    People with diabetes should always wear a medical alert bracelet or necklace that emergency medical workers will be able to find. Medical identification products can help ensure proper treatment in an ...

  1. DDBS DB Alert

    Data.gov (United States)

    Social Security Administration — Data store used by the database area for monitoring of database objects. It is used to generate alerts that the DBAs investigate to determine if any action needs to...

  2. Lower alert rates by clustering of related drug interaction alerts

    NARCIS (Netherlands)

    Heringa, M.; Siderius, Hidde; Schreudering, A.; De Smet, Peter Agm; Bouvy, M.L.

    OBJECTIVE: We aimed to investigate to what extent clustering of related drug interaction alerts (drug-drug and drug-disease interaction alerts) would decrease the alert rate in clinical decision support systems (CDSSs). METHODS: We conducted a retrospective analysis of drug interaction alerts

  3. Sensitivity analysis on the performances of a closed-loop Ground Source Heat Pump

    Science.gov (United States)

    Casasso, Alessandro; Sethi, Rajandrea

    2014-05-01

    Ground Source Heat Pumps (GSHP) permit to achieve a significant reduction of greenhouse gas emissions, and the margins for economic saving of this technology are strongly correlated to the long-term sustainability of the exploitation of the heat stored in the soil. The operation of a GSHP over its lifetime should be therefore modelled considering realistic conditions, and a thorough characterization of the physical properties of the soil is essential to avoid large errors of prediction. In this work, a BHE modelling procedure with the finite-element code FEFLOW is presented. Starting from the governing equations of the heat transport in the soil around a GSHP and inside the BHE, the most important parameters are individuated and the adopted program settings are explained. A sensitivity analysis is then carried on both the design parameters of the heat exchanger, in order to understand the margins of improvement of a careful design and installation, and the physical properties of the soil, with the aim of quantifying the uncertainty induced by their variability. The relative importance of each parameter is therefore assessed by comparing the statistical distributions of the fluid temperatures and estimating the energy consumption of the heat pump, and practical conclusions are from these results about the site characterization, the design and the installation of a BHE. References Casasso A., Sethi R., 2014 Efficiency of closed loop geothermal heat pumps: A sensitivity analysis, Renewable Energy 62 (2014), pp. 737-746 Chiasson A.C., Rees S.J., Spitler J.D., 2000, A preliminary assessment of the effects of groundwater flow on closed-loop ground-source heat pump systems, ASHRAE Transactions 106 (2000), pp. 380-393 Delaleux F., Py X., Olives R., Dominguez A., 2012, Enhancement of geothermal borehole heat exchangers performances by improvement of bentonite grouts conductivity, Applied Thermal Engineering 33-34, pp. 92-99 Diao N., Li Q., Fang Z., 2004, Heat transfer in

  4. Hybrid Ground-Source Heat Pump Installations: Experiences, Improvements, and Tools

    Energy Technology Data Exchange (ETDEWEB)

    Scott Hackel; Amanda Pertzborn

    2011-06-30

    One innovation to ground-source heat pump (GSHP, or GHP) systems is the hybrid GSHP (HyGSHP) system, which can dramatically decrease the first cost of GSHP systems by using conventional technology (such as a cooling tower or a boiler) to meet a portion of the peak heating or cooling load. This work uses three case studies (two cooling-dominated, one heating-dominated) to demonstrate the performance of the hybrid approach. Three buildings were studied for a year; the measured data was used to validate models of each system. The models were used to analyze further improvements to the hybrid approach, and establish that this approach has positive impacts, both economically and environmentally. Lessons learned by those who design and operate the systems are also documented, including discussions of equipment sizing, pump operation, and cooling tower control. Finally, the measured data sets and models that were created during this work are described; these materials have been made freely available for further study of hybrid systems.

  5. The application of ground source heat pumps to a subdivision-wide district heating system

    International Nuclear Information System (INIS)

    Ciavaglia, L.

    2005-01-01

    Design guidelines for economic ground source heat pumps (GSHP) in district energy systems were presented. The broad economics of using central GSHP in a community district energy system were examined. Design parameters needed to utilize GSHP in district energy system were outlined. The sensitivity of energy prices and the costs of major capital were reviewed. District heating load duration curves were outlined. It was suggested that varying GSHP capacity from 0 to 100 per cent of load was advisable. In addition, capacity should be balanced with gas boiler technology. The amortizing of capital within energy costs was recommended. It was suggested that the best scenario was a minimum of 50 per cent ground energy. Details of pipings and heat exchanger costs were presented, along with costs for gas boilers and gas costs for the district energy system. Charts of current costing and reduction of piping capital were included. It was concluded that GSHP can be a viable component of a district energy system, as a GSHP based district energy system can provide more stable energy prices than conventional fossil fuel systems. It was suggested that sizing of GSHP at, or near, 40 per cent of peak demand provided optimal conditions with respect to energy cost and use of earth energy. tabs., figs

  6. Geothermal(Ground-Source)Heat Pumps: Market Status, Barriers to Adoption, and Actions to Overcome Barriers

    Energy Technology Data Exchange (ETDEWEB)

    Hughes, Patrick [ORNL

    2008-12-01

    More effective stewardship of our resources contributes to the security, environmental sustainability, and economic well-being of the nation. Buildings present one of the best opportunities to economically reduce energy consumption and limit greenhouse gas emissions. Geothermal heat pumps (GHPs), sometimes called ground-source heat pumps, have been proven capable of producing large reductions in energy use and peak demand in buildings. However, GHPs have received little attention at the policy level as an important component of a national strategy. Have policymakers mistakenly overlooked GHPs, or are GHPs simply unable to make a major contribution to the national goals for various reasons? This brief study was undertaken at DOE's request to address this conundrum. The scope of the study includes determining the status of global GHP markets and the status of the GHP industry and technology in the United States, assembling previous estimates of GHP energy savings potential, identifying key barriers to application of GHPs, and identifying actions that could accelerate market adoption of GHPs. The findings are documented in this report along with conclusions and recommendations.

  7. Detailed Theoretical Characterization of a Transcritical CO2 Direct Expansion Ground Source Heat Pump Water Heater

    Directory of Open Access Journals (Sweden)

    Parham Eslami-Nejad

    2018-02-01

    Full Text Available A new avenue in modern heat pump technology is related to the use of natural refrigerants such as carbon dioxide (CO2. The use of CO2 in direct expansion ground source heat pumps (DX-GSHP has also gained significant interest as it offers opportunities for cost reduction of the ground loop, albeit some challenges remain in their development, design and use. To address these challenges and to characterize CO2-DX-GSHP performance for water heating applications, a detailed theoretical model and a fully-instrumented test apparatus was developed and built at CanmetENERGY Research Laboratory. The theoretical model was validated against a set of experimental results and adopted to investigate the performance of the system over a wide operating range. Validation results showed that the model predicts the experimental results within the measurement uncertainty. A detailed system performance analysis was also performed using the theoretical model to understand the system behavior and explore the actions required for performance improvement in future installations. The results of the analysis showed that improper design and control of some components, such as the gas cooler and ground heat exchanger can degrade the system performance by up to 25%, and the heat pump heating capacity by 7.5%.

  8. Focus group discussions among owners and non-owners of ground source heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Roberson, B.F.

    1988-07-01

    This research was sponsored by the Office of Buildings and Community Systems and conducted by the Pacific Northwest Laboratory as part of an ongoing effort to enhance the commercial use of federally developed technology. Federal dollars have supported research on the development of ground source heat pumps (GSHP) for several years. Though several companies currently sell GSHP's for residential use, their share of the total heating and air conditioning business remains less than one percent. Large manufacturing companies with national distribution have not yet added GSHP equipment to their product line. GSHP's use only about one half (Braud 1987) to one third (Bose 1987) of the energy needed to operate conventional furnaces and air conditioners. Consequently, a high level of market penetration by the GSHP offers direct benefits to both utility companies and individual users of the systems. Widespread use of these highly efficient systems will reduce both total energy consupmtion, and problems associated with high levels of energy use during peak periods. This will allow utility companies to delay capital expenditures for new facilities to meet the growing energy demand during peak periods. The cost effective use of electricity also reduces the likelihood of homeowners switching to a different fuel source for heating. 5 refs.

  9. National Certification Standard for Ground Source Heat Pump Personnel

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, John [Geothermal Heat Pump Consortium, Washington, DC (United States)

    2013-07-31

    The National Certification Standard for the Geothermal Heat Pump Industry adds to the understanding of the barriers to rapid growth of the geothermal heat pump (GHP) industry by bringing together for the first time an analysis of the roles and responsibilities of each of the individual job tasks involved in the design and installation of GHP systems. The standard addresses applicable qualifications for all primary personnel involved in the design, installation, commissioning, operation and maintenance of GHP systems, including their knowledge, skills and abilities. The resulting standard serves as a foundation for subsequent development of curriculum, training and certification programs, which are not included in the scope of this project, but are briefly addressed in the standard to describe ways in which the standard developed in this project may form a foundation to support further progress in accomplishing those other efforts. Follow-on efforts may use the standard developed in this project to improve the technical effectiveness and economic feasibility of curriculum development and training programs for GHP industry personnel, by providing a more complete and objective assessment of the individual job tasks necessary for successful implementation of GHP systems. When incorporated into future certification programs for GHP personnel, the standard will facilitate increased consumer confidence in GHP technology, reduce the potential for improperly installed GHP systems, and assure GHP system quality and performance, all of which benefit the public through improved energy efficiency and mitigated environmental impacts of the heating and cooling of homes and businesses.

  10. IEA HPP Annex 29 - ground-source heat pumps overcoming technical and market barriers. Status report Norway

    International Nuclear Information System (INIS)

    Stene, Joern

    2004-12-01

    Norway is a member of Annex 29, 'Ground-Source Heat Pump Systems Overcoming Technical and Market Barriers' (2004-2006), organized under the umbrella of the International Energy Agency (IEA) and the IEA Heat Pump Programme (HPP). The 7 participating countries are Austria (Operating Agent), Canada, Japan, Norway, Spain, Sweden and the USA. The Norwegian participation is financed by ENOVA SF, and SINTEF Energy Research is responsible for planning and carrying out the Norwegian activities. This report provides a status for ground-source heat pump (GSHP) systems in Norway with regard to state-of-the-art technology, installation examples, geological data, costs and market opportunities. A Norwegian Internet home page for ground-source heat pump systems (www.energy.sintef.no/prosjekt/Annex29) is also presented. GSHP systems in Norway are classified as direct systems (groundwater and soil/ground) and indirect closed-loop systems (vertical-rock and horizontal-soil/ground). The vast majority of the installations are indirect closed-loop systems utilizing vertical boreholes in rock as a heat source, heat sink and thermal energy storage. GSHP systems are relatively capital intensive installations, but they achieve high energy efficiency due to the relatively high and stable heat source temperature and the fact that a considerable share of the cooling demand in non-residential buildings can be covered by means of free cooling. In order to obtain energy efficient and reliable GSHP installations, it is important to implement a total quality concept where focus is on quality and system integration during all stages of the project. A life cycle analysis (LCA) will be an important tool in such a concept, since both the investment costs as well as the lifetime operational and maintenance costs are included (author) (ml) Litt usikker pae tag 620- ikke en vanlig sintef rapportkode

  11. Physicians’ use of computerized clinical decision supports to improve medication management in the elderly – the Seniors Medication Alert and Review Technology intervention

    Directory of Open Access Journals (Sweden)

    Alagiakrishnan K

    2016-01-01

    Full Text Available Kannayiram Alagiakrishnan,1 Patricia Wilson,2 Cheryl A Sadowski,3 Darryl Rolfson,1 Mark Ballermann,4,5 Allen Ausford,6,7 Karla Vermeer,7 Kunal Mohindra,8 Jacques Romney,9 Robert S Hayward10 1Department of Medicine, Division of Geriatric Medicine, 2Department of Medicine, 3Faculty of Pharmacy and Pharmaceutical Sciences, University of Alberta, 4Chief Medical Information Office, Alberta Health Services, 5Division of Critical Care, Department of Medicine, University of Alberta, 6Department of Family Medicine, University of Alberta, 7Lynwood Family Physician, 8eClinician EMR, Alberta Health Services-Information Systems, 9Department of Medicine, Division of Endocrinology, 10Division of General Internal Medicine, University of Alberta, Edmonton, AB, Canada Background: Elderly people (aged 65 years or more are at increased risk of polypharmacy (five or more medications, inappropriate medication use, and associated increased health care costs. The use of clinical decision support (CDS within an electronic medical record (EMR could improve medication safety.Methods: Participatory action research methods were applied to preproduction design and development and postproduction optimization of an EMR-embedded CDS implementation of the Beers’ Criteria for medication management and the Cockcroft–Gault formula for estimating glomerular filtration rates (GFR. The “Seniors Medication Alert and Review Technologies” (SMART intervention was used in primary care and geriatrics specialty clinics. Passive (chart messages and active (order-entry alerts prompts exposed potentially inappropriate medications, decreased GFR, and the possible need for medication adjustments. Physician reactions were assessed using surveys, EMR simulations, focus groups, and semi-structured interviews. EMR audit data were used to identify eligible patient encounters, the frequency of CDS events, how alerts were managed, and when evidence links were followed.Results: Analysis of

  12. Case Study for the ARRA-Funded Ground Source Heat Pump Demonstration at Ball State University

    Energy Technology Data Exchange (ETDEWEB)

    Im, Piljae [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Liu, Xiaobing [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Henderson, Jr., Hugh [CDH Energy Corp., Beijing (China)

    2016-12-01

    With funding provided by the American Recovery and Reinvestment Act (ARRA), 26 ground-source heat pump (GSHP) projects were competitively selected in 2009 to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. One of the selected demonstration projects is a district central GSHP system installed at Ball State University (BSU) in Muncie, IN. Prior to implementing the district GSHP system, 47 major buildings in BSU were served by a central steam plant with four coal-fired and three natural-gas-fired steam boilers. Cooling was provided by five water-cooled centrifugal chillers at the District Energy Station South (DESS). The new district GSHP system replaced the existing coal-fired steam boilers and conventional water-cooled chillers. It uses ground-coupled heat recovery (HR) chillers to meet the simultaneous heating and cooling demands of the campus. The actual performance of the GSHP system was analyzed based on available measured data from August 2015 through July 2016, construction drawings, maintenance records, personal communications, and construction costs. Since Phase 1 was funded in part by the ARRA grant, it is the focus of this case study. The annual energy consumption of the GSHP system was calculated based on the available measured data and other related information. It was compared with the performance of a baseline scenario— a conventional water-cooled chiller and natural-gas-fired boiler system, both of which meet the minimum energy efficiencies allowed by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE 90.1-2013). The comparison was made to determine source energy savings, energy cost savings, and CO2 emission reductions achieved by the GSHP system. A cost analysis was performed to evaluate the simple payback of the GSHP system. The following sections summarize the results of the analysis, the lessons learned, and recommendations for improvement

  13. Project "Hypertension Alert."

    Science.gov (United States)

    Sailors, Emma Lou

    1983-01-01

    "Hypertension Alert," a 1979-80 blood pressure screening-awareness project of the Yonkers, New York Public Schools, is described. Data is analyzed in tables for ethnic composition, and range of blood pressure readings for the high school, junior high school, and elementary school students tested. (Author/JMK)

  14. Sensor Alerting Capability

    Science.gov (United States)

    Henriksson, Jakob; Bermudez, Luis; Satapathy, Goutam

    2013-04-01

    There is a large amount of sensor data generated today by various sensors, from in-situ buoys to mobile underwater gliders. Providing sensor data to the users through standardized services, language and data model is the promise of OGC's Sensor Web Enablement (SWE) initiative. As the amount of data grows it is becoming difficult for data providers, planners and managers to ensure reliability of data and services and to monitor critical data changes. Intelligent Automation Inc. (IAI) is developing a net-centric alerting capability to address these issues. The capability is built on Sensor Observation Services (SOSs), which is used to collect and monitor sensor data. The alerts can be configured at the service level and at the sensor data level. For example it can alert for irregular data delivery events or a geo-temporal statistic of sensor data crossing a preset threshold. The capability provides multiple delivery mechanisms and protocols, including traditional techniques such as email and RSS. With this capability decision makers can monitor their assets and data streams, correct failures or be alerted about a coming phenomena.

  15. Alerts in mobile healthcare applications: requirements and pilot study.

    Science.gov (United States)

    Kafeza, Eleanna; Chiu, Dickson K W; Cheung, S C; Kafeza, Marina

    2004-06-01

    Recent advances in mobile technologies have greatly extended traditional communication technologies to mobile devices. At the same time, healthcare environments are by nature "mobile" where doctors and nurses do not have fixed workspaces. Irregular and exceptional events are generated in daily hospital routines, such as operations rescheduling, laboratory/examination results, and adverse drug events. These events may create requests that should be delivered to the appropriate person at the appropriate time. Those requests that are classified as urgent are referred to as alerts. Efficient routing and monitoring of alerts are keys to quality and cost-effective healthcare services. Presently, these are generally handled in an ad hoc manner. In this paper, we propose the use of a healthcare alert management system to handle these alert messages systematically. We develop a model for specifying alerts that are associated with medical tasks and a set of parameters for their routing. We design an alert monitor that matches medical staff and their mobile devices to receive alerts, based on the requirements of these alerts. We also propose a mechanism to handle and reroute, if necessary, an alert message when it has not been acknowledged within a specific deadline.

  16. 75 FR 67201 - Flightcrew Alerting

    Science.gov (United States)

    2010-11-02

    ... two different senses for warning and caution alerts. Identifying an alert and determining corrective... pilots to the urgency that should be associated with the meaning of these colors, which could increase... consistent and standardized color usage is desirable to ensure the pilot understands the urgency of an alert...

  17. Ground source heat pumps (GSHP) for heating and cooling in Greece

    Science.gov (United States)

    Dimera, Nikoletta

    This report presents the results of a theoretical study about the feasibility of closed loop Ground Source Heat Pumps (GSHP) for heating and cooling in Greece in terms of their impact on the capital and running costs of the building services systems of the buildings. The main aim of carrying out this study was to investigate if the heating and cooling potential of the ground could be utilized cost efficiently to serve the buildings energy demand in the Greek region. At first, an existing implementation of a closed loop GSHP system in Greece is presented and its efficiency is discussed. The aim of doing so was to understand the way of sizing such systems and the efficiency of this technology in Greek climatic and ground conditions. In a separate part of this report, the impact of different user behaviour and of various ways of sizing a GSHP system is investigated in terms of the cost impact of the examined different options as well as of their effect on the internal health and comfort conditions. After the building simulation under different scenarios, it was concluded that the user behavior - the operation of windows mostly - can result in great savings on the annual energy bills. The conclusions of this first part of the report about the user behaviour and the way of sizing GSHP systems were utilized in the next part of it, where a GSHP system is proposed for a building currently under construction in central Greece. A simple 30-year cost analysis was used in order to estimate the performance of the proposed GSHP system in economic terms and to compare it with the conventional HVAC system commonly used in Greece. According to the results of the analysis, the capital cost of installing a GSHP system for heating and cooling in buildings in Greece appears higher than the cost of conventional HVAC systems. More specifically, the capital cost of an installation for heating including gas boilers and a cooling system based on air conditioning split units is about the

  18. Ground source heat pump performance in case of high humidity soil and yearly balanced heat transfer

    International Nuclear Information System (INIS)

    Schibuola, Luigi; Tambani, Chiara; Zarrella, Angelo; Scarpa, Massimiliano

    2013-01-01

    Highlights: • GSHPs are simulated in case of humid soil and yearly balanced heat transfer. • Humid soil and yearly balanced heat transfer imply higher compactness of GSHPs. • Resulting GSHPs are compared with other traditional and innovative HVAC systems. • GSHPs score best, especially in case of inverter-driven compressors. - Abstract: Ground source heat pump (GSHP) systems are spreading also in Southern Europe, due to their high energy efficiency both in heating and in cooling mode. Moreover, they are particularly suitable in historical cities because of difficulties in the integration of heating/cooling systems into buildings subjected to historical preservation regulations. In these cases, GSHP systems, especially the ones provided with borehole heat exchangers, are a suitable solution instead of gas boilers, air-cooled chillers or cooling towers. In humid soils, GSHP systems are even more interesting because of their enhanced performance due to higher values of soil thermal conductivity and capacity. In this paper, GSHP systems operating under these boundary conditions are analyzed through a specific case study set in Venice and related to the restoration of an historical building. With this analysis the relevant influences of soil thermal conductivity and yearly balanced heat transfer in the design of the borehole field are shown. In particular, the paper shows the possibility to achieve higher compactness of the borehole field footprint area when yearly balanced heat transfer in the borehole field is expected. Then, the second set of results contained in the paper shows how GSHP systems designed for high humidity soils and yearly balanced heat loads at the ground side, even if characterized by a compact footprint area, may still ensure better performance than other available and more common technologies such as boilers, air-cooled chillers, chillers coupled with cooling towers and heat pumps and chillers coupled with lagoon water. As a consequence

  19. Sky alert! when satellites fail

    CERN Document Server

    Johnson, Les

    2013-01-01

    How much do we depend on space satellites? Defense, travel, agriculture, weather forecasting, mobile phones and broadband, commerce...the list seems endless. But what would our live be like if the unimaginable happened and, by accident or design, those space assets disappeared? Sky Alert! explores what our world would be like, looking in turn at areas where the loss could have catastrophic effects. The book - demonstrates our dependence on space technology and satellites; - outlines the effect on our economy, defense, and daily lives if satellites and orbiting spacecraft were destroyed; - illustrates the danger of dead satellites, spent rocket stages, and space debris colliding with a functioning satellites; - demonstrates the threat of dramatically increased radiation levels associated with geomagnetic storms; - introduces space as a potential area of conflict between nations.

  20. 75 FR 26269 - Draft Programmatic Environmental Assessment for the Integrated Public Alert and Warning Program's...

    Science.gov (United States)

    2010-05-11

    ... system to alert and warn the American people in situations of war, terrorist attack, natural disaster, or... Order 13407, Public Alert and Warning System, by providing robust and survivable power generation, fuel... of interoperable public alert and warning systems, to identify technologies and standards that...

  1. Experimental performance analysis of a direct-expansion ground source heat pump in Xiangtan, China

    International Nuclear Information System (INIS)

    Yang, Wei

    2013-01-01

    The DX GSHP (direct-expansion ground source heat pump), which uses a buried copper piping network through which refrigerant is circulated, is one type of GSHP (ground source heat pump). This study investigates the performance characteristics of a vertical U-bend direct-expansion ground source (geothermal) heat pump system (DX GSHPS) for both heating and cooling. Compared with the conventional GCHP (ground coupled heat pump) system, the DX GSHP system is more efficient, with lower thermal resistance in the GHE (ground heat exchanger) and a lower (higher) condensing (evaporating) temperature in the cooling (heating) mode. In addition, the system performance of the whole DX GSHP system is also higher than that of the conventional GCHP system. A DX GSHP system in Xiangtan, China with a U-bend ground heat exchanger 42 m deep with a nominal outside diameter of 12.7 mm buried in a water well was tested and analysed. The results showed that the performance of this system is very high. The maximum (average) COPs of the system were found to be 6.08 (4.73) and 6.32 (5.03) in the heating and cooling modes, respectively. - Highlights: • The reasons for the higher performance of the DX GSHP (direct-expansion ground source heat pump) are analysed theoretically compared with the conventional GCHP (ground coupled heat pump). • The experimental performance of a DX GSHP system is investigated, which makes a valuable contribution to the literature. • The study is helpful in demonstrating the energy efficiency of the DX GSHP system

  2. Ground Source Heat Pumps vs. Conventional HVAC: A Comparison of Economic and Environmental Costs

    Science.gov (United States)

    2009-03-26

    of systems are surface water heat pumps (SWHPs), ground water heat pumps (GWHPs), and ground coupled heat pumps ( GCHPs ) (Kavanaugh & Rafferty, 1997...Kavanaugh & Rafferty, 1997). Ground Coupled Heat Pumps (Closed-Loop Ground Source Heat Pumps) GCHPs , otherwise known as closed-loop GSHPs, are the...Significant confusion has arisen through the use of GCHP and closed-loop GSHP terminology. Closed-loop GSHP is the preferred nomenclature for this

  3. Simulation of embedded heat exchangers of solar aided ground source heat pump system

    Institute of Scientific and Technical Information of China (English)

    王芳; 郑茂余; 邵俊鹏; 李忠建

    2008-01-01

    Aimed at unbalance of soil temperature field of ground source heat pump system, solar aided energy storage system was established. In solar assisted ground-source heat pump (SAGSHP) system with soil storage, solar energy collected in three seasons was stored in the soil by vertical U type soil exchangers. The heat abstracted by the ground-source heat pump and collected by the solar collector was employed to heating. Some of the soil heat exchangers were used to store solar energy in the soil so as to be used in next winter after this heating period; and the others were used to extract cooling energy directly in the soil by circulation pump for air conditioning in summer. After that solar energy began to be stored in the soil and ended before heating period. Three dimensional dynamic numerical simulations were built for soil and soil heat exchanger through finite element method. Simulation was done in different strata month by month. Variation and restoration of soil temperature were studied. Economy and reliability of long term SAGSHP system were revealed. It can be seen that soil temperature is about 3 ℃ higher than the original one after one year’s running. It is beneficial for the system to operate for long period.

  4. Alerting or Somnogenic Light: Pick Your Color

    Science.gov (United States)

    Bourgin, Patrice; Hubbard, Jeffrey

    2016-01-01

    In mammals, light exerts pervasive effects on physiology and behavior in two ways: indirectly through clock synchronization and the phase adjustment of circadian rhythms, and directly through the promotion of alertness and sleep, respectively, in diurnal and nocturnal species. A recent report by Pilorz and colleagues describes an even more complex role for the acute effects of light. In mice, blue light acutely causes behavioral arousal, whereas green wavelengths promote sleep. These opposing effects are mediated by melanopsin-based phototransduction through different neural pathways. These findings reconcile nocturnal and diurnal species through a common alerting response to blue light. One can hypothesize that the opposite responses to natural polychromatic light in night- or day-active animals may reflect higher sensitivity of nocturnal species to green, and diurnals to blue wavelengths, resulting in hypnogenic and alerting effects, respectively. Additional questions remain to be clarified. How do different light wavelengths affect other behaviors such as mood and cognition? How do those results apply to humans? How does light pose either a risk or benefit, depending on whether one needs to be asleep or alert? Indeed, in addition to timing, luminance levels, and light exposure duration, these findings stress the need to understand how best to adapt the color spectrum of light to our needs and to take this into account for the design of daily lighting concepts—a key challenge for today’s society, especially with the emergence of LED light technology. PMID:27525420

  5. Alerting or Somnogenic Light: Pick Your Color.

    Directory of Open Access Journals (Sweden)

    Patrice Bourgin

    2016-08-01

    Full Text Available In mammals, light exerts pervasive effects on physiology and behavior in two ways: indirectly through clock synchronization and the phase adjustment of circadian rhythms, and directly through the promotion of alertness and sleep, respectively, in diurnal and nocturnal species. A recent report by Pilorz and colleagues describes an even more complex role for the acute effects of light. In mice, blue light acutely causes behavioral arousal, whereas green wavelengths promote sleep. These opposing effects are mediated by melanopsin-based phototransduction through different neural pathways. These findings reconcile nocturnal and diurnal species through a common alerting response to blue light. One can hypothesize that the opposite responses to natural polychromatic light in night- or day-active animals may reflect higher sensitivity of nocturnal species to green, and diurnals to blue wavelengths, resulting in hypnogenic and alerting effects, respectively. Additional questions remain to be clarified. How do different light wavelengths affect other behaviors such as mood and cognition? How do those results apply to humans? How does light pose either a risk or benefit, depending on whether one needs to be asleep or alert? Indeed, in addition to timing, luminance levels, and light exposure duration, these findings stress the need to understand how best to adapt the color spectrum of light to our needs and to take this into account for the design of daily lighting concepts-a key challenge for today's society, especially with the emergence of LED light technology.

  6. PleurAlert: an augmented chest drainage system with electronic sensing, automated alerts and internet connectivity.

    Science.gov (United States)

    Leeson, Cory E; Weaver, Robert A; Bissell, Taylor; Hoyer, Rachel; McClain, Corinne; Nelson, Douglas A; Samosky, Joseph T

    2012-01-01

    We have enhanced a common medical device, the chest tube drainage container, with electronic sensing of fluid volume, automated detection of critical alarm conditions and the ability to automatically send alert text messages to a nurse's cell phone. The PleurAlert system provides a simple touch-screen interface and can graphically display chest tube output over time. Our design augments a device whose basic function dates back 50 years by adding technology to automate and optimize a monitoring process that can be time consuming and inconvenient for nurses. The system may also enhance detection of emergency conditions and speed response time.

  7. Toxic substances alert program

    Science.gov (United States)

    Junod, T. L.

    1978-01-01

    A toxicity profile is provided, of 187 toxic substances procured by NASA Lewis Research Center during a 3 1/2 year period, including 27 known or suspected carcinogens. The goal of the program is to assure that the center's health and safety personnel are aware of the procurement and use of toxic substances and to alert and inform the users of these materials as to the toxic characteristics and the control measures needed to ensure their safe use. The program also provides a continuing record of the toxic substances procured, who procured them, what other toxic substances the user has obtained in the past, and where similar materials have been used elsewhere at the center.

  8. Ground source thermo-pumps for individual residential houses; Les thermopompes a capteur enterres dans les residences individuelles

    Energy Technology Data Exchange (ETDEWEB)

    Ossant, G. [Societe Syrec (France)

    1997-12-31

    The main principles, performances and constraints of the various types of ground source thermo-pumps for individual houses, i.e. ground/ground thermo-pumps, glycol water/water thermo-pumps and ground/water thermo-pumps are reviewed, and their energy consumptions are discussed. The design and operating conditions of a reverse ground source thermo-pump (Syrec) for space heating and air conditioning through a hot and cold floor system and a Syrec ground source thermo-pump for water heating, are presented

  9. Hybrid ground-source heat pump system with active air source regeneration

    International Nuclear Information System (INIS)

    Allaerts, K.; Coomans, M.; Salenbien, R.

    2015-01-01

    Highlights: • A hybrid ground source heat pump system with two separate borefields is modelled. • The maximum underground storage temperature depends on the size of the drycooler. • Drycooler selection curves are given as function of underground storage temperature. • The size of the cold storage is reduced with 47% in the cost optimal configuration. • The cooling seasonal performance factor decreases with reduced storage capacity. - Abstract: Ground-source heat pump systems (GSHP) offer great advantages over traditional heating and cooling installations. However, their applications are limited due to the high initial costs of borehole drilling. One way to avoid these costs is by reducing the size of the borefield, e.g. by combining the system with other renewable energy sources or by using active regeneration to increase the system efficiency. In this paper a hybrid ground-source heat pump system (HGSHP) is analyzed. The borefield is split into a warm part and a cold part, which allows for seasonal thermal-energy storage. Additionally, supplementary drycoolers capture heat during summer and cold during winter. The relationship between the underground storage size and temperature and the drycooler capacity is described, using an office building in Flanders (Belgium) as reference case. Results show that with a HGSHP system a significant borefield size reduction can be achieved without compromising system performance; i.e. for the reference case a reduction of 47% was achieved in the cost-optimal configuration. It is also shown that the cooling seasonal performance factor decreases significantly with underground storage capacity. In addition, the HGSHP can be used to maintain or restore thermal balance in the geothermal source when heating and cooling loads do not match

  10. Ground-source heat pump barometer - EurObserv'ER - September 2011

    International Nuclear Information System (INIS)

    2011-09-01

    2,9% slide by the GHSP market in the EU between 2009 and 2010. The double whammy dealt by the economic crisis and housing slump has stifled expansion of the ground-source heat pump market in many European countries. The European Union market contracted for the second year running (by 2.9% between 2009 and 2010), and this despite the fact that more than 100 000 units were sold over the twelve-month period, taking the number of installed units past the one million mark

  11. A feasible system integrating combined heating and power system with ground-source heat pump

    International Nuclear Information System (INIS)

    Li, HongQiang; Kang, ShuShuo; Yu, Zhun; Cai, Bo; Zhang, GuoQiang

    2014-01-01

    A system integrating CHP (combined heating and power) subsystem based on natural gas and GSHP (ground-source heat pump subsystem) in series is proposed. By help of simulation software-Aspen Plus, the energy performance of a typical CHP and GSHP-S (S refers to ‘in series’) system was analyzed. The results show that the system can make a better use of waste heat in flue gas from CHP (combined heating and power subsystem). The total system energy efficiency is 123% and the COP (coefficient of performance) of GSHP (ground-source heat pump) subsystem is 5.3. A referenced CHP and GSHP-P (P refers to ‘in parallel’) system is used for comparison; its total system energy efficiency and COP of GSHP subsystem are 118.6% and 3.5 respectively. Compared with CHP and GSHP-P system with different operating parameters, the CHP and GSHP-S system can increase total system energy efficiency by 0.8–34.7%, with related output ratio of heat to power (R) from 1.9 to 18.3. Furthermore, the COP of GSHP subsystem can be increased between the range 3.6 and 6, which is much higher than that in conventional CHP and GSHP-P system. This study will be helpful for other efficient GSHP systems integrating if there is waste heat or other heat resources with low temperature. - Highlights: • CHP system based on natural gas and ground source heat pump. • The new system can make a better utilization of waste heat in flue gas by a special way. • The proposed system can realize energy saving potential from 0.8 to 34.7%. • The coefficient of performance of ground source heat pump subsystem is significantly improved from 3.5 to 3.6–6. • Warm water temperature and percentage of flue gas used to reheat are key parameters

  12. Alert management for home healthcare based on home automation analysis.

    Science.gov (United States)

    Truong, T T; de Lamotte, F; Diguet, J-Ph; Said-Hocine, F

    2010-01-01

    Rising healthcare for elder and disabled people can be controlled by offering people autonomy at home by means of information technology. In this paper, we present an original and sensorless alert management solution which performs multimedia and home automation service discrimination and extracts highly regular home activities as sensors for alert management. The results of simulation data, based on real context, allow us to evaluate our approach before application to real data.

  13. Experimental Study and Modeling of Ground-Source Heat Pumps with Combi-Storage in Buildings

    Directory of Open Access Journals (Sweden)

    Wessam El-Baz

    2018-05-01

    Full Text Available There is a continuous growth of heat pump installations in residential buildings in Germany. The heat pumps are not only used for space heating and domestic hot water consumption but also to offer flexibility to the grid. The high coefficient of performance and the low cost of heat storages made the heat pumps one of the optimal candidates for the power to heat applications. Thus, several questions are raised about the optimal integration and control of heat pump system with buffer storages to maximize its operation efficiency and minimize the operation costs. In this paper, an experimental investigation is performed to study the performance of a ground source heat pump (GSHP with a combi-storage under several configurations and control factors. The experiments were performed on an innovative modular testbed that is capable of emulating a ground source to provide the heat pump with different temperature levels at different times of the day. Moreover, it can emulate the different building loads such as the space heating load and the domestic hot water consumption in real-time. The data gathered from the testbed and different experimental studies were used to develop a simulation model based on Modelica that can accurately simulate the dynamics of a GSHP in a building. The model was validated based on different metrics. Energetically, the difference between the developed model and the measured values was only 3% and 4% for the heat generation and electricity consumption, respectively.

  14. A new energy analysis tool for ground source heat pump systems

    Energy Technology Data Exchange (ETDEWEB)

    Michopoulos, A.; Kyriakis, N. [Process Equipment Design Laboratory, Mechanical Engineering Department, Aristotle University of Thessaloniki, POB 487, 541 24 Thessaloniki (Greece)

    2009-09-15

    A new tool, suitable for energy analysis of vertical ground source heat pump systems, is presented. The tool is based on analytical equations describing the heat exchanged with the ground, developed in Matlab {sup registered} environment. The time step of the simulation can be freely chosen by the user (e.g. 1, 2 h etc.) and the calculation time required is very short. The heating and cooling loads of the building, at the afore mentioned time step, are needed as input, along with the thermophysical properties of the soil and of the ground heat exchanger, the operation characteristic curves of the system's heat pumps and the basic ground source heat exchanger dimensions. The results include the electricity consumption of the system and the heat absorbed from or rejected to the ground. The efficiency of the tool is verified through comparison with actual electricity consumption data collected from an existing large scale ground coupled heat pump installation over a three-year period. (author)

  15. Multi-objective optimization of a vertical ground source heat pump using evolutionary algorithm

    International Nuclear Information System (INIS)

    Sayyaadi, Hoseyn; Amlashi, Emad Hadaddi; Amidpour, Majid

    2009-01-01

    Thermodynamic and thermoeconomic optimization of a vertical ground source heat pump system has been studied. A model based on the energy and exergy analysis is presented here. An economic model of the system is developed according to the Total Revenue Requirement (TRR) method. The objective functions based on the thermodynamic and thermoeconomic analysis are developed. The proposed vertical ground source heat pump system including eight decision variables is considered for optimization. An artificial intelligence technique known as evolutionary algorithm (EA) has been utilized as an optimization method. This approach has been applied to minimize either the total levelized cost of the system product or the exergy destruction of the system. Three levels of optimization including thermodynamic single objective, thermoeconomic single objective and multi-objective optimizations are performed. In Multi-objective optimization, both thermodynamic and thermoeconomic objectives are considered, simultaneously. In the case of multi-objective optimization, an example of decision-making process for selection of the final solution from available optimal points on Pareto frontier is presented. The results obtained using the various optimization approaches are compared and discussed. Further, the sensitivity of optimized systems to the interest rate, to the annual number of operating hours and to the electricity cost are studied in detail.

  16. Seasonal coefficient of performance for ground source heat pump and groundwater one in Białystok

    Science.gov (United States)

    Gajewski, Andrzej

    2017-11-01

    European Economic Area (EEA) states declare to contain greenhouse gases emissions at 20% by 2020, whereas European Union (EU) does 40% before 2030, which result in encouragement to apply low-carbon technologies. Coefficient of Performance (COP) and Seasonal Coefficient of Performance (SCOPnet) are obtained using temperature measurement done by The Institute of Meteorology and Water Management - National Research Institute (IMGW-PIB) at the weather station in Bialystok for ten-year period. The first variant is ground source heat pump (GSHP) and the second one is groundwater source heat pump (WSHP) which can be equipped with separating heat exchanger (SHE) optionally. In both cases heat is generated for heating system only. Ground temperature is determined from Baggs (1983) formula using Oleśkowicz-Popiel et. al. (2002) adaptation to Polish climate and substituting the local constants achieved by Biernacka (2010). Water temperature in a groundwater basin is obtained from Kowalski (2007) equation. Estimation is done in each hour of heating season. All COP values are higher than 3.5 required by EU (2013). SCOPnet are as follows: 6.12, 5.86, 5.03 for WSHP, WSHP+SHE, GSHP respectively. Insomuch as WSHP needs only two boreholes it is recommended to the areas beneath ones a groundwater basin is located.

  17. Seasonal coefficient of performance for ground source heat pump and groundwater one in Białystok

    Directory of Open Access Journals (Sweden)

    Gajewski Andrzej

    2017-01-01

    Full Text Available European Economic Area (EEA states declare to contain greenhouse gases emissions at 20% by 2020, whereas European Union (EU does 40% before 2030, which result in encouragement to apply low-carbon technologies. Coefficient of Performance (COP and Seasonal Coefficient of Performance (SCOPnet are obtained using temperature measurement done by The Institute of Meteorology and Water Management – National Research Institute (IMGW-PIB at the weather station in Bialystok for ten-year period. The first variant is ground source heat pump (GSHP and the second one is groundwater source heat pump (WSHP which can be equipped with separating heat exchanger (SHE optionally. In both cases heat is generated for heating system only. Ground temperature is determined from Baggs (1983 formula using Oleśkowicz-Popiel et. al. (2002 adaptation to Polish climate and substituting the local constants achieved by Biernacka (2010. Water temperature in a groundwater basin is obtained from Kowalski (2007 equation. Estimation is done in each hour of heating season. All COP values are higher than 3.5 required by EU (2013. SCOPnet are as follows: 6.12, 5.86, 5.03 for WSHP, WSHP+SHE, GSHP respectively. Insomuch as WSHP needs only two boreholes it is recommended to the areas beneath ones a groundwater basin is located.

  18. Development and Experimental Validation of a TRNSYS Dynamic Tool for Design and Energy Optimization of Ground Source Heat Pump Systems

    Directory of Open Access Journals (Sweden)

    Félix Ruiz-Calvo

    2017-09-01

    Full Text Available Ground source heat pump (GSHP systems stand for an efficient technology for renewable heating and cooling in buildings. To optimize not only the design but also the operation of the system, a complete dynamic model becomes a highly useful tool, since it allows testing any design modifications and different optimization strategies without actually implementing them at the experimental facility. Usually, this type of systems presents strong dynamic operating conditions. Therefore, the model should be able to predict not only the steady-state behavior of the system but also the short-term response. This paper presents a complete GSHP system model based on an experimental facility, located at Universitat Politècnica de València. The installation was constructed in the framework of a European collaborative project with title GeoCool. The model, developed in TRNSYS, has been validated against experimental data, and it accurately predicts both the short- and long-term behavior of the system.

  19. Automated acute kidney injury alerts.

    Science.gov (United States)

    Kashani, Kianoush B

    2018-05-02

    Acute kidney injury (AKI) is one of the most common and probably one of the more consequential complications of critical illnesses. Recent information indicates that it is at least partially preventable; however, progress in its prevention, management, and treatment has been hindered by the scarcity of knowledge for effective interventions, inconsistencies in clinical practices, late identification of patients at risk for or with AKI, and limitations of access to best practices for prevention and management of AKI. Growing use of electronic health records has provided a platform for computer science to engage in data mining and processing, not only for early detection of AKI but also for the development of risk-stratification strategies and computer clinical decision-support (CDS) systems. Despite promising perspectives, the literature regarding the impact of AKI electronic alerts and CDS systems has been conflicting. Some studies have reported improvement in care processes and patient outcomes, whereas others have shown no effect on clinical outcomes and yet demonstrated an increase in the use of resources. These discrepancies are thought to be due to multiple factors that may be related to technology, human factors, modes of delivery of information to clinical providers, and level of expectations regarding the impact on patient outcomes. This review appraises the current body of knowledge and provides some outlines regarding research into and clinical aspects of CDS systems for AKI. Copyright © 2018 International Society of Nephrology. Published by Elsevier Inc. All rights reserved.

  20. Case Study for the ARRA-funded Ground Source Heat Pump Demonstration at Denver Museum of Nature & Science

    Energy Technology Data Exchange (ETDEWEB)

    Im, Piljae [ORNL; Liu, Xiaobing [ORNL

    2016-09-01

    High initial costs and lack of public awareness of ground-source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy-saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects were competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This report highlights the findings of a case study of one such GSHP demonstration projects that uses a recycled water heat pump (RWHP) system installed at the Denver Museum of Nature & Science in Denver, Colorado. The RWHP system uses recycled water from the city’s water system as the heat sink and source for a modular water-to-water heat pump (WWHP). This case study was conducted based on the available measured performance data from December 2014 through August 2015, utility bills of the building in 2014 and 2015, construction drawings, maintenance records, personal communications, and construction costs. The annual energy consumption of the RWHP system was calculated based on the available measured data and other related information. It was compared with the performance of a baseline scenario— a conventional VAV system using a water-cooled chiller and a natural gas fired boiler, both of which have the minimum energy efficiencies allowed by ASHRAE 90.1-2010. The comparison was made to determine energy savings, operating cost savings, and CO2 emission reductions achieved by the RWHP system. A cost analysis was performed to evaluate the simple payback of the RWHP system. Summarized below are the results of the performance analysis, the learned lessons, and recommended improvement in the operation of the RWHP system.

  1. A new CERN Alerter mechanism

    CERN Multimedia

    2007-01-01

    A new version of the CERN Alerter used for sending urgent messages was installed in July on all centrally managed NICE computers. This latest version is based on RSS (Really Simple Syndication) and all alerts are now displayed in an Internet Explorer window (see the picture). You can print the window by right-clicking on the alert background and selecting the Print option from the menu. If the message is not urgent, then the alert will only appear as a "balloon" window the following morning or at next logon. Non-Windows computers can also subscribe to this service by using their browser as an RSS reader (Really Simple Syndication). All recent web browsers can act as RSS readers, including Firefox and Safari. Simply subscribe to the following RSS feed: http://cern.ch/cernalerts/alerts.aspx to see all messages sent by the central services. More information on the CERN Alerter is available at: https://cern.ch/winservices/Help/?kbid=060810. Documentation on reading RSS feeds fr...

  2. A new CERN Alerter mechanism

    CERN Multimedia

    2007-01-01

    A new version of the CERN Alerter used for sending urgent messages was installed in July on all centrally managed NICE computers. This latest version is based on RSS (Really Simple Syndication) and all alerts are now displayed in an Internet Explorer window (see picture). You can print the window by right-clicking on the alert background and selecting the Print option from the menu. If the message is not urgent, the alert will only appear as a "balloon" window the following morning or at next log-on. Non-Windows computers can also subscribe to this service by using their browser as an RSS reader. All recent web browsers can act as RSS readers, including Firefox and Safari. Simply subscribe to the following RSS feed: http://cern.ch/cernalerts/alerts.aspx to see all messages sent by the central services. More information on the CERN Alerter is available at: https://cern.ch/winservices/Help/?kbid=060810. Documentation on reading RSS fee...

  3. Performance analysis on a large scale borehole ground source heat pump in Tianjin cultural centre

    Science.gov (United States)

    Yin, Baoquan; Wu, Xiaoting

    2018-02-01

    In this paper, the temperature distribution of the geothermal field for the vertical borehole ground-coupled heat pump was tested and analysed. Besides the borehole ground-coupled heat pump, the system composed of the ice storage, heat supply network and cooling tower. According to the operation data for nearly three years, the temperature constant zone is in the ground depth of 40m -120m with a temperature gradient of about 3.0°C/100m. The temperature of the soil dropped significantly in the heating season, increased significantly in the cooling season, and reinstated in the transitional season. With the energy balance design of the heating and cooling and the existence of the soil thermal inertia, the soil temperature stayed in a relative stable range and the ground source heat pump system was operated with a relative high efficiency. The geothermal source heat pump was shown to be applicable for large scale utilization.

  4. Ground Source Heat Pump Sub-Slab Heat Exchange Loop Performance in a Cold Climate

    Energy Technology Data Exchange (ETDEWEB)

    Mittereder, Nick [IBACOS, Inc., Pittsburgh, PA (United States); Poerschke, Andrew [IBACOS, Inc., Pittsburgh, PA (United States)

    2013-11-01

    This report presents a cold-climate project that examines an alternative approach to ground source heat pump (GSHP) ground loop design. The innovative ground loop design is an attempt to reduce the installed cost of the ground loop heat exchange portion of the system by containing the entire ground loop within the excavated location beneath the basement slab. Prior to the installation and operation of the sub-slab heat exchanger, energy modeling using TRNSYS software and concurrent design efforts were performed to determine the size and orientation of the system. One key parameter in the design is the installation of the GSHP in a low-load home, which considerably reduces the needed capacity of the ground loop heat exchanger. This report analyzes data from two cooling seasons and one heating season.

  5. Ground source heat pump retrofit at North Bonneville, WA City Hall

    Energy Technology Data Exchange (ETDEWEB)

    Hughey, M. [Skamania Co. PUD No. 1, Carson, WA (United States)

    1997-12-31

    In 1995, the City of North Bonneville, WA installed a 10-ton Ground Source Heat Pump (GSHP) to replace the electric resistance furnace in its 4,000 square, foot City Hall. North Bonneville is 30 miles east of Portland, Oregon, at river level in the Columbia River Gorge. Funded jointly by the Bonneville Power Administration, the State of Washington and the City, this project has successfully reduced the heating cost of City Hall by nearly one-half while dramatically increasing comfort. It has become a commercial model in the Pacific Northwest for assessing values of commercial GSHP retrofits. This interim report compares estimated savings with actual experience for the first operating year. Projected savings were $1,500; actual savings were $1,390 prior to adjustment for extreme weather. Adjusted savings for Heating Year 1996 were $1,490, a 47 percent decrease. Maintenance savings (not itemized) were in addition to this amount. Monitoring continues in 1997.

  6. Exergy analysis of a two-stage ground source heat pump with a vertical bore for residential space conditioning under simulated occupancy

    International Nuclear Information System (INIS)

    Ally, Moonis R.; Munk, Jeffrey D.; Baxter, Van D.; Gehl, Anthony C.

    2015-01-01

    Highlights: • Exergy and energy analysis of a vertical-bore ground source heat pump over a 12-month period is presented. • The ground provided more than 75% of the heating energy. • Performance metrics are presented. • Sources of systemic inefficiency are identified and prioritized using Exergy analysis. • Understanding performance metrics is vital for judicial use of renewable energy. - Abstract: This twelve-month field study analyzes the performance of a 7.56 W (2.16-ton) water-to-air-ground source heat pump (WA-GSHP) to satisfy domestic space conditioning loads in a 253 m 2 house in a mixed-humid climate in the United States. The practical feasibility of using the ground as a source of renewable energy is clearly demonstrated. Better than 75% of the energy needed for space heating was extracted from the ground. The average monthly electricity consumption for space conditioning was only 40 kW h at summer and winter thermostat set points of 24.4 °C and 21.7 °C, respectively. The WA-GSHP shared the same 94.5 m vertical bore ground loop with a separate water-to-water ground-source heat pump (WW-GSHP) for meeting domestic hot water needs in the same house. Sources of systemic irreversibility, the main cause of lost work, are identified using Exergy and energy analysis. Quantifying the sources of Exergy and energy losses is essential for further systemic improvements. The research findings suggest that the WA-GSHPs are a practical and viable technology to reduce primary energy consumption and greenhouse gas emissions under the IECC 2012 Standard, as well as the European Union (EU) 2020 targets of using renewable energy resources

  7. Heat transfer analysis of underground U-type heat exchanger of ground source heat pump system.

    Science.gov (United States)

    Pei, Guihong; Zhang, Liyin

    2016-01-01

    Ground source heat pumps is a building energy conservation technique. The underground buried pipe heat exchanging system of a ground source heat pump (GSHP) is the basis for the normal operation of an entire heat pump system. Computational-fluid-dynamics (CFD) numerical simulation software, ANSYS-FLUENT17.0 have been performed the calculations under the working conditions of a continuous and intermittent operation over 7 days on a GSHP with a single-well, single-U and double-U heat exchanger and the impact of single-U and double-U buried heat pipes on the surrounding rock-soil temperature field and the impact of intermittent operation and continuous operation on the outlet water temperature. The influence on the rock-soil temperature is approximately 13 % higher for the double-U heat exchanger than that of the single-U heat exchanger. The extracted energy of the intermittent operation is 36.44 kw·h higher than that of the continuous mode, although the running time is lower than that of continuous mode, over the course of 7 days. The thermal interference loss and quantity of heat exchanged for unit well depths at steady-state condition of 2.5 De, 3 De, 4 De, 4.5 De, 5 De, 5.5 De and 6 De of sidetube spacing are detailed in this work. The simulation results of seven working conditions are compared. It is recommended that the side-tube spacing of double-U underground pipes shall be greater than or equal to five times of outer diameter (borehole diameter: 180 mm).

  8. The Common Alerting Protocol (CAP) adaption in National Early Warning Alerting Systems of China

    Science.gov (United States)

    Li, Chao

    2017-04-01

    The Common Alerting Protocol (CAP) [1] is an XML-based data format for exchanging public warnings and emergencies between alerting technologies. In China, from local communities to entire nations, there was a patchwork of specialized hazard public alerting systems. And each system was often designed just for certain emergency situations and for certain communications media. Application took place in the NEWAS (National Early Warning Alerting Systems) [2]project where CAP serves as central message to integrate all kind of hazard situations, including the natural calamity, accident disaster, public health emergency , social safety etc. Officially operated on May 2015, NEWAS now has completed docking work with 14 departments including civil administration, safety supervision, forestry, land, water conservancy, earthquake, traffic, meteorology, agriculture, tourism, food and drug supervision, public security and oceanic administration. Thus, several items in CAP has been modified, redefined and extended according to the various grading standards and publishing strategies, as well as the characteristics of Chinese Geocoding. NEWAS successfully delivers information to end users through 4 levels (i.e. State, province, prefecture and county) structure and by various means. [1] CAP, http://www.oasis-emergency.org/cap [2] http://www.12379.cn/

  9. Analysis of Fuel Cell Driven Ground Source Heat Pump Systems in Community Buildings

    Directory of Open Access Journals (Sweden)

    Jong-Keun Shin

    2013-05-01

    Full Text Available In the present study, a fuel cell driven ground source heat pump (GSHP system is applied in a community building and heat pump system performance is analyzed by computational methods. Conduction heat transfer between the brine pipe and ground is analyzed by TEACH code in order to predict the performance of the heat pump system. The predicted coefficient of performance (COP of the heat pump system and the energy cost were compared with the variation of the location of the objective building, the water saturation rate of the soil, and the driven powers of the heat pump system. Compared to the late-night electricity driven system, a significant reduction of energy cost can be accomplished by employing the fuel cell driven heat pump system. This is due to the low cost of electricity production of the fuel cell system and to the application of the recovered waste heat generated during the electricity production process to the heating of the community building.

  10. Domestic Hot Water Production with Ground Source Heat Pump in Apartment Buildings

    Directory of Open Access Journals (Sweden)

    Jukka Yrjölä

    2015-08-01

    Full Text Available Producing domestic hot water (DHW with a ground source heat pump (GSHP is challenging due to the high temperature (HT of DHW. There are many studies proving the better performance of cascade heat pumps compared to single-stage heat pumps when the difference between the condensing and the evaporation temperature is large. In this system approach study, different GSHP arrangements are described and computationally compared. A two-stage heat pump arrangement is introduced in which water tanks of the heating system are utilized for warming up the DHW in two stages. It is shown that the electricity consumption with this two-stage system is approximately 31% less than with the single-stage heat pump and 12% less than with the cascade system. Further, both low temperature (LT and HT heat pumps can run alone, which is not common in cascade or other two-stage heat pumps. This is advantageous because the high loads of the space heating and DHW production are not simultaneous. Proper insulation of the DHW and recirculation pipe network is essential, and drying towel rails or other heating coils should be avoided when aiming for a high efficiency. The refrigerants in the calculations are R407C for the LT heat pump and R134a for the HT heat pump. Investment costs are excluded from calculations.

  11. Ground Source Heat Pump Sub-Slab Heat Exchange Loop Performance in a Cold Climate

    Energy Technology Data Exchange (ETDEWEB)

    Mittereder, N.; Poerschke, A.

    2013-11-01

    This report presents a cold-climate project that examines an alternative approach to ground source heat pump (GSHP) ground loop design. The innovative ground loop design is an attempt to reduce the installed cost of the ground loop heat exchange portion of the system by containing the entire ground loop within the excavated location beneath the basement slab. Prior to the installation and operation of the sub-slab heat exchanger, energy modeling using TRNSYS software and concurrent design efforts were performed to determine the size and orientation of the system. One key parameter in the design is the installation of the GSHP in a low-load home, which considerably reduces the needed capacity of the ground loop heat exchanger. This report analyzes data from two cooling seasons and one heating season. Upon completion of the monitoring phase, measurements revealed that the initial TRNSYS simulated horizontal sub-slab ground loop heat exchanger fluid temperatures and heat transfer rates differed from the measured values. To determine the cause of this discrepancy, an updated model was developed utilizing a new TRNSYS subroutine for simulating sub-slab heat exchangers. Measurements of fluid temperature, soil temperature, and heat transfer were used to validate the updated model.

  12. On sustainable and efficient design of ground-source heat pump systems

    Science.gov (United States)

    Grassi, W.; Conti, P.; Schito, E.; Testi, D.

    2015-11-01

    This paper is mainly aimed at stressing some fundamental features of the GSHP design and is based on a broad research we are performing at the University of Pisa. In particular, we focus the discussion on an environmentally sustainable approach, based on performance optimization during the entire operational life. The proposed methodology aims at investigating design and management strategies to find the optimal level of exploitation of the ground source and refer to other technical means to cover the remaining energy requirements and modulate the power peaks. The method is holistic, considering the system as a whole, rather than focusing only on some components, usually considered as the most important ones. Each subsystem is modeled and coupled to the others in a full set of equations, which is used within an optimization routine to reproduce the operative performances of the overall GSHP system. As a matter of fact, the recommended methodology is a 4-in-1 activity, including sizing of components, lifecycle performance evaluation, optimization process, and feasibility analysis. The paper reviews also some previous works concerning possible applications of the proposed methodology. In conclusion, we describe undergoing research activities and objectives of future works.

  13. Ground source energy in crystalline bedrock - increased energy extraction by using hydraulic fracturing in boreholes

    Energy Technology Data Exchange (ETDEWEB)

    Ramstad, Randi Kalstad

    2004-11-01

    The use of improved equipment and methodology can result in considerable reductions in the drilling costs for medium- to large sized ground source heat pump system in crystalline bedrock. The main point has been to use special techniques within hydraulic fracturing to create a larger heat exchange area in the bedrock, and thus a greater energy extraction per borehole. The energy extraction is based on circulating groundwater. Stimulation with hydraulic fracturing is a well known technique in order to improve borehole yields for drinking water-, oil-, and geothermal purposes. A procedure for injection of propping agents in selected borehole sections, and custom-made equipment for hydraulic fracturing in crystalline bedrock, a double packer, have been developed in this study. The propping agents are likely to ensure a permanent improvement of the hydraulic conductivity in a long-run perspective. In addition to a pre-test, a comprehensive test programme has been performed at each of the two pilot plants at Bryn and at the former property of Energiselskapet Asker og Baerum (EAB) in Baerum municipality outside Oslo, Norway. A total of 125 stimulations with hydraulic fracturing using water-only and hydraulic fracturing with injection of sand have been performed in 9 boreholes. Test pumping and geophysical logging (temperature, electrical conductivity, gamma radiation, optical televiewer and flow measurements) have been carried out in order to document the effect of the hydraulic fracturing. The pilot plants at Bryn and EAB, where the ground source heat pump systems are based on circulating groundwater, have demonstrated the short-period energy extraction, limitations and opportunities of the concept for hydraulic fracturing and increased energy extraction in different geological and hydrogeological areas. The bedrock at Bryn and EAB is characterized as a low-metamorphic sandstone and a nodular limestone, respectively. At Bryn, the five boreholes were organised with a

  14. Soil temperature distribution around a U-tube heat exchanger in a multi-function ground source heat pump system

    International Nuclear Information System (INIS)

    Li Shuhong; Yang Weihua; Zhang Xiaosong

    2009-01-01

    The imbalance of heat extracted from the earth by the underground heat exchangers in winter and ejected into it in summer is expected to affect the long term performance of conventional ground source heat pump (GSHP) in territories with a cold winter and a warm summer such as the middle and downstream areas of the Yangtze River in China. This paper presents a new multi-function ground source heat pump (MFGSHP) system which supplies hot water as well as space cooling/heating to mitigate the soil imbalance of the extracted and ejected heat by a ground source heat pump system. The heat transfer characteristic is studied and the soil temperature around the underground heat exchangers are simulated under a typical climatic condition of the Yangtze River. A three-dimensional model was constructed with the commercial computational fluid dynamics software FLUENT based on the inner heat source theory. Temperature distribution and variation trend of a tube cluster of the underground heat exchanger are simulated for the long term performance. The results show that the soil temperature around the underground tube keeps increasing due to the surplus heat ejected into the earth in summer, which deteriorates the system performance and may lead to the eventual system deterioration. The simulation shows that MFGSHP can effectively alleviate the temperature rise by balancing the heat ejected to/extracted from underground by the conventional ground source heat pump system. The new system also improves the energy efficiency.

  15. Recovery Act: Finite Volume Based Computer Program for Ground Source Heat Pump Systems

    Energy Technology Data Exchange (ETDEWEB)

    James A Menart, Professor

    2013-02-22

    This report is a compilation of the work that has been done on the grant DE-EE0002805 entitled Finite Volume Based Computer Program for Ground Source Heat Pump Systems. The goal of this project was to develop a detailed computer simulation tool for GSHP (ground source heat pump) heating and cooling systems. Two such tools were developed as part of this DOE (Department of Energy) grant; the first is a two-dimensional computer program called GEO2D and the second is a three-dimensional computer program called GEO3D. Both of these simulation tools provide an extensive array of results to the user. A unique aspect of both these simulation tools is the complete temperature profile information calculated and presented. Complete temperature profiles throughout the ground, casing, tube wall, and fluid are provided as a function of time. The fluid temperatures from and to the heat pump, as a function of time, are also provided. In addition to temperature information, detailed heat rate information at several locations as a function of time is determined. Heat rates between the heat pump and the building indoor environment, between the working fluid and the heat pump, and between the working fluid and the ground are computed. The heat rates between the ground and the working fluid are calculated as a function time and position along the ground loop. The heating and cooling loads of the building being fitted with a GSHP are determined with the computer program developed by DOE called ENERGYPLUS. Lastly COP (coefficient of performance) results as a function of time are provided. Both the two-dimensional and three-dimensional computer programs developed as part of this work are based upon a detailed finite volume solution of the energy equation for the ground and ground loop. Real heat pump characteristics are entered into the program and used to model the heat pump performance. Thus these computer tools simulate the coupled performance of the ground loop and the heat pump. The

  16. Finite Volume Based Computer Program for Ground Source Heat Pump System

    Energy Technology Data Exchange (ETDEWEB)

    Menart, James A. [Wright State University

    2013-02-22

    This report is a compilation of the work that has been done on the grant DE-EE0002805 entitled ?Finite Volume Based Computer Program for Ground Source Heat Pump Systems.? The goal of this project was to develop a detailed computer simulation tool for GSHP (ground source heat pump) heating and cooling systems. Two such tools were developed as part of this DOE (Department of Energy) grant; the first is a two-dimensional computer program called GEO2D and the second is a three-dimensional computer program called GEO3D. Both of these simulation tools provide an extensive array of results to the user. A unique aspect of both these simulation tools is the complete temperature profile information calculated and presented. Complete temperature profiles throughout the ground, casing, tube wall, and fluid are provided as a function of time. The fluid temperatures from and to the heat pump, as a function of time, are also provided. In addition to temperature information, detailed heat rate information at several locations as a function of time is determined. Heat rates between the heat pump and the building indoor environment, between the working fluid and the heat pump, and between the working fluid and the ground are computed. The heat rates between the ground and the working fluid are calculated as a function time and position along the ground loop. The heating and cooling loads of the building being fitted with a GSHP are determined with the computer program developed by DOE called ENERGYPLUS. Lastly COP (coefficient of performance) results as a function of time are provided. Both the two-dimensional and three-dimensional computer programs developed as part of this work are based upon a detailed finite volume solution of the energy equation for the ground and ground loop. Real heat pump characteristics are entered into the program and used to model the heat pump performance. Thus these computer tools simulate the coupled performance of the ground loop and the heat pump

  17. Ground source heat pumps versus high efficiency natural gas furnaces in Alberta

    Energy Technology Data Exchange (ETDEWEB)

    Shaw, J.

    2003-02-02

    For the past twenty years or so, the heating and cooling of numerous buildings in northern Europe has been accomplished using ground source heat pumps (GSHPs), while in North America they have been in use for approximately ten years. In the Prairies, natural gas furnaces dominate, while GSHP are more popular in eastern Canada. The author noted that natural gas furnaces have an efficiency of 80 per cent or less, while high efficiency natural gas (HENG) furnaces, more expensive, have an efficiency in the 90 per cent range. A brief outline of the principles behind GSHPs was provided. The Coefficient of Performance (COP) of GSHP reaches up to 500 per cent depending whether the unit is cooling or heating. The amount of heat produced by a heating system expressed as a percentage of the energy input required to operate the system is the definition used for the efficiency. In those cases where it is possible to amortize the initial costs, pay now or obtain a subsidy, the installation of GSHP is advantageous. Several factors affect the total cost of heating a building, such as the airtightness of the building and its insulation, the coldness of the climate, and the inside controlled temperature setting. The author then examined the cost of operating a GSHP versus a natural gas furnace. In most examples studied, the cost of operating a GSHP was less than the cost of operating a natural gas furnace. The Total Equivalent Warming Impact (TEWI) of GSHPs and HENG furnaces was examined. The author concluded that the cost of heating by GSHP in Alberta will be lower than the cost of heating by HENG which requires a separate air conditioning unit for the summer months, with additional improvements in efficiency and insulation. 7 refs., 4 tabs.

  18. Exergoeconomic analysis of a solar assisted ground-source heat pump greenhouse heating system

    International Nuclear Information System (INIS)

    Ozgener, Onder; Hepbasli, Arif

    2005-01-01

    EXCEM analysis may prove useful to investigators in engineering and other disciplines due to the methodology are being based on the quantities exergy, cost, energy and mass. The main objective of the present study is to investigate between capital costs and thermodynamic losses for devices in solar assisted ground-source heat pump greenhouse heating system (SAGSHPGHS) with a 50 m vertical 32 mm nominal diameter U-bend ground heat exchanger. This system was designed and installed at the Solar Energy Institute, Ege University, Izmir, Turkey. Thermodynamic loss rate-to-capital cost ratios are used to show that, for components and the overall system, a systematic correlation appears to exist between capital cost and exergy loss (total or internal), but not between capital cost and energy loss or external exergy loss. This correlation may imply that devices in successful air conditioning are configured so as to achieve an overall optimal design, by appropriately balancing the thermodynamic (exergy-based) and economic characteristics of the overall system and its devices. The results may, (i) provide useful insights into the relations between thermodynamics and economics, both in general and for SAGSHPGHS (ii) help demonstrate the merits of second-law analysis. It is observed from the results that the maximum exergy destructions in the system particularly occur due to the electrical, mechanical and isentropic efficiencies and emphasize the need for paying close attention to the selection of this type of equipment, since components of inferior performance can considerably reduce the overall performance of the system. In conjunction with this, the total exergy losses values are obtained to be from 0.010 kW to 0.480 kW for the system. As expected, the largest energy and exergy losses occur in the greenhouse and compressor. The ratio of thermodynamic loss rate to capital cost values are obtained for a range from 0.035 to 1.125

  19. Impact of global warming on performance of ground source heat pumps in US climate zones

    International Nuclear Information System (INIS)

    Shen, Pengyuan; Lukes, Jennifer R.

    2015-01-01

    Highlights: • Used morphing method to have downscaled hourly local weather data from GCM. • Selected representative cities in different climate zones in the US for case study on GSHP performance. • Used hourly building simulation tools (eQuest and TRNSYS) to project GSHP performance in future. • Analysis on GSHP performance in 2050 for both residential and office building in the US are conducted. - Abstract: Ground source heat pumps (GSHP) have attracted increasing attention because of their high energy efficiencies. The aim of this paper is to study the performance of (GSHP) in future climate conditions (2040–2069) by using projected future hourly weather data of selected representative cities in the US to estimate future ground temperature change. The projected hourly weather data and estimated ground temperatures are input to an hourly simulation tool (TRNSYS and eQuest for this research), which provides reliable coupling of GSHP system and building performance. The simulation results show that global warming will decrease the energy efficiency of GSHP in US residential buildings because a rise in inlet and outlet water temperature is predicted for GSHP systems during the cooling season and because buildings will become more cooling dominated in the future. For office buildings, although the cooling performance of GSHP will not drop significantly under future climate, the overall energy efficiency for the system will decrease due to the increasing energy consumption of the ground loop pump. In the future, considering the significant ground heat imbalance for GSHP operation, GSHP will become less competitive both economically and technically than it is now in the context of US climate zones

  20. Ground Source Heat Supply in Moscow Oblast: Temperature Potential and Sustainable Depth of Heat Wells

    Science.gov (United States)

    Vasil'ev, G. P.; Gornov, V. F.; Dmitriev, A. N.; Kolesova, M. V.; Yurchenko, V. A.

    2018-01-01

    The paper is devoted to a problem of increasing the efficiency of low-potential geothermal heat in heat pump systems of residential buildings the Moscow oblast of Russia, including Moscow. Estimates of a natural geothermal potential in the Moscow oblast (based on climatological data for the period from 1982 to 2011) are presented and a "Typical climatic year of natural soil temperature variations for the geoclimatic conditions of the Moscow oblast, including the city of Moscow" is proposed. Numerical simulation of the influence of geothermal energy potential and the depth of heat wells on the efficiency of ground source heat pump systems for the heat supply of residential buildings is carried out. Analysis of the numerical simulation showed that the operation of a heat pump system in a house heating mode under the geoclimatic conditions of the Moscow oblast leads to a temperature drop of the heat-exchange medium circulating through heat wells to 5-6°C by the end of the first 10 years of operation, and the process stabilizes by the 15th year of operation, and further changes in the heat-exchange medium temperature do not any longer significantly affect the temperature of the heat-exchange medium in the heat well. In this case, the exact dependence of the heat-exchange medium temperature drop on the depth is not revealed. Data on the economically expedient heat well depth for the conditions of the Moscow oblast ensuring a net present value for the whole residential building life cycle are presented. It is found that the heat well depth of 60 m can be considered as an endpoint for the Moscow oblast, and a further heat well deepening is economically impractical.

  1. Automated attendance management and alert system | Rahim ...

    African Journals Online (AJOL)

    Automated attendance management and alert system. ... Journal of Fundamental and Applied Sciences ... AAMAS provides various functions, from managing and recording students' attendance record, to sending automatic alerts to students ...

  2. Les lanceurs d’alerte

    OpenAIRE

    Foegle, Jean-Philippe

    2014-01-01

    Le lanceur ou « donneur » d'alerte, ou, en langue anglaise, whistleblower est défini par l'assemblée parlementaire du conseil de l'Europe (Résolution 1729 (2010), §1) comme « toute personne soucieuse qui tire la sonnette d’alarme afin de faire cesser des agissements pouvant représenter un risque pour autrui ». Le présent mémoire vise, en menant une étude comparée France-Etats-Unis du droit encadrant le phénomène du « lancement d'alerte », à cerner les éléments principaux de la notion. Le prem...

  3. Optimization of operating parameters of ground source heat pump system for space heating and cooling by Taguchi method and utility concept

    International Nuclear Information System (INIS)

    Sivasakthivel, T.; Murugesan, K.; Thomas, H.R.

    2014-01-01

    Highlights: • Ground Source Heat Pump (GSHP) technology is suitable for both heating and cooling. • Important parameters that affect the GSHP performance has been listed. • Parameters of GSHP system has been optimized for heating and cooling mode. • Taguchi technique and utility concept are developed for GSHP optimization. - Abstract: Use of ground source energy for space heating applications through Ground Source Heat pump (GSHP) has been established as an efficient thermodynamic process. The electricity input to the GSHP can be reduced by increasing the COP of the system. However, the COP of a GSHP system will be different for heating and cooling mode operations. Hence in order to reduce the electricity input to the GSHP, an optimum value of COP has to be determined when GSHP is operated in both heating and cooling modes. In the present research, a methodology is proposed to optimize the operating parameters of a GSHP system which will operate on both heating and cooling modes. Condenser inlet temperature, condenser outlet temperature, dryness fraction at evaporator inlet and evaporator outlet temperature are considered as the influencing parameters of the heat pump. Optimization of these parameters for only heating or only cooling mode operation is achieved by employing Taguchi method for three level variations of the above parameters using an L 9 (3 4 ) orthogonal array. Higher the better concept has been used to get a higher COP. A computer program in FORTAN has been developed to carry out the computations and the results have been analyzed for the optimum conditions using Signal-to-Noise (SN) ratio and Analysis Of Variance (ANOVA) method. Based on this analysis, the maximum COP for only heating and only cooling operation are obtained as 4.25 and 3.32 respectively. By making use of the utility concept both the higher values of COP obtained for heating and cooling modes are optimized to get a single optimum COP for heating and cooling modes. A single

  4. Optimization of systems with the combination of ground-source heat pump and solar collectors in dwellings

    DEFF Research Database (Denmark)

    Kjellsson, Elisabeth; Hellström, Göran; Perers, Bengt

    2010-01-01

    The use of ground-source heat pumps for heating and domestic hot water in dwellings is common in Sweden. The combination with solar collectors has been introduced to reduce the electricity demand in the system. In order to analyze different systems with combinations of solar collectors and ground......-source heat pumps, computer simulations have been carried out with the simulation program TRNSYS. Large differences were found between the system alternatives. The optimal design is when solar heat produces domestic hot water during summertime and recharges the borehole during wintertime. The advantage...... is related to the rate of heat extraction from the borehole as well as the overall design of the system. The demand of electricity may increase with solar recharging, because of the increased operating time of the circulation pumps. Another advantage with solar heat in combination with heat pumps is when...

  5. NAPS as an Alertness Management Strategy

    Science.gov (United States)

    Rosekind, Mark R.; Smith, Roy M.; Miller, Donna L.; Co, Elizabeth L.; Gregory, Kevin B.; Gander, Philippa H.; Lebacqz, J. Victor

    2001-01-01

    Today, 24-hour operations are necessary to meet the demands of our society and the requirements of our industrialized global economy. These around-the-clock demands pose unique physiological challenges for the humans who remain central to safe and productive operations. Optimal alertness and performance are critical factors that are increasingly challenged by unusual, extended, or changing work/rest schedules. Technological advancements and automated systems can exacerbate the challenges faced by the human factor in these environments. Shift work, transportation demands, and continuous operations engender sleep loss and circadian disruption. Both of these physiological factors can lead to increased sleepiness, decreased performance, and a reduced margin of safety. These factors can increase vulnerability to incidents and accidents in operational settings. The consequences can have both societal effects (e.g., major destructive accidents such as Three Mile Island, Exxon Valdez, Bhopal) and personal effects (e.g., an accident driving home after a night shift).

  6. False alerts in air traffic control conflict alerting system: is there a "cry wolf" effect?

    Science.gov (United States)

    Wickens, Christopher D; Rice, Stephen; Keller, David; Hutchins, Shaun; Hughes, Jamie; Clayton, Krisstal

    2009-08-01

    The aim is to establish the extent to which the high false-alarm rate of air traffic control midair conflict alerts is responsible for a "cry wolf' effect-where true alerts are not responded to and all alerts are delayed in their response. Some aircraft collisions have been partly attributed to the cry wolf effect, and in other domains (health care and systems monitoring), there is a causal connection between false-alarm rate and cry wolf behavior. We hypothesized that a corresponding relationship exists in air traffic control (ATC). Aircraft track and alert system behavior data surrounding 495 conflict alerts were analyzed to identify true and false alerts, trajectory type, and controller behavior. Forty-five percent of the alerts were false, ranging from 0.28 to 0.58. Although centers with more false alerts contributed to more nonresponses, there was no evidence that these were nonresponses to true alerts or that response times were delayed in those centers. Instead, controllers showed desirable anticipatory behavior by issuing trajectory changes prior to the alert. Those trajectory pairs whose conflicts were more difficult to visualize induced more reliance on, and less compliance with, the alerting system. The high false-alarm rate does not appear to induce cry wolf behavior in the context of en route ATC conflict alerts. There is no need to substantially modify conflict alert algorithms, but the conflict alert system may be modified to address difficult-to-visualize conflicts.

  7. Case Study for the ARRA-funded Ground Source Heat Pump (GSHP) Demonstration at Wilders Grove Solid Waste Service Center in Raleigh, NC

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xiaobing [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Malhotra, Mini [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Xiong, Zeyu [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-11-01

    High initial costs and lack of public awareness of ground-source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy-saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects have been competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This paper highlights the findings of a case study of one of the ARRA-funded GSHP demonstration projects, a distributed GSHP system for providing all the space conditioning, outdoor air ventilation, and 100% domestic hot water to the Wilders Grove Solid Waste Service Center of City of Raleigh, North Carolina. This case study is based on the analysis of measured performance data, construction costs, and simulations of the energy consumption of conventional central heating, ventilation, and air-conditioning (HVAC) systems providing the same level of space conditioning and outdoor air ventilation as the demonstrated GSHP system. The evaluated performance metrics include the energy efficiency of the heat pump equipment and the overall GSHP system, pumping performance, energy savings, carbon emission reductions, and cost-effectiveness of the GSHP system compared with conventional HVAC systems. This case study also identified opportunities for reducing uncertainties in the performance evaluation and improving the operational efficiency of the demonstrated GSHP system.

  8. Wearable PPG sensor based alertness scoring system.

    Science.gov (United States)

    Dey, Jishnu; Bhowmik, Tanmoy; Sahoo, Saswata; Tiwari, Vijay Narayan

    2017-07-01

    Quantifying mental alertness in today's world is important as it enables the person to adopt lifestyle changes for better work efficiency. Miniaturized sensors in wearable devices have facilitated detection/monitoring of mental alertness. Photoplethysmography (PPG) sensors through Heart Rate Variability (HRV) offer one such opportunity by providing information about one's daily alertness levels without requiring any manual interference from the user. In this paper, a smartwatch based alertness estimation system is proposed. Data collected from PPG sensor of smartwatch is processed and fed to machine learning based model to get a continuous alertness score. Utility functions are designed based on statistical analysis to give a quality score on different stages of alertness such as awake, long sleep and short duration power nap. An intelligent data collection approach is proposed in collaboration with the motion sensor in the smartwatch to reduce battery drainage. Overall, our proposed wearable based system provides a detailed analysis of alertness over a period in a systematic and optimized manner. We were able to achieve an accuracy of 80.1% for sleep/awake classification along with alertness score. This opens up the possibility for quantifying alertness levels using a single PPG sensor for better management of health related activities including sleep.

  9. Post-evaluation of a ground source heat pump system for residential space heating in Shanghai China

    Science.gov (United States)

    Lei, Y.; Tan, H. W.; Wang, L. Z.

    2017-11-01

    Residents of Southern China are increasingly concerned about the space heating in winter. The chief aim of the present work is to find a cost-effective way for residential space heating in Shanghai, one of the biggest city in south China. Economic and energy efficiency of three residential space heating ways, including ground source heat pump (GSHP), air source heat pump (ASHP) and wall-hung gas boiler (WHGB), are assessed based on Long-term measured data. The results show that the heat consumption of the building is 120 kWh/m2/y during the heating season, and the seasonal energy efficiency ratio (SEER) of the GSHP, ASHP and WHGB systems are 3.27, 2.30, 0.88 respectively. Compared to ASHP and WHGB, energy savings of GSHP during the heating season are 6.2 kgce/(m2.y) and 2.2 kgce/(m2.y), and the payback period of GSHP are 13.3 and 7.6 years respectively. The sensitivity analysis of various factors that affect the payback period is carried out, and the results suggest that SEER is the most critical factor affecting the feasibility of ground source heat pump application, followed by building load factor and energy price factor. These findings of the research have led the author to the conclusion that ground source heat pump for residential space heating in Shanghai is a good alternative, which can achieve significant energy saving benefits, and a good system design and operation management are key factors that can shorten the payback period.

  10. RSS based CERN Alerter. Information broadcast to all CERN offices.

    CERN Multimedia

    Otto, R

    2007-01-01

    Nearly every large organization uses a tool to broadcast messages and information across the internal campus (messages like alerts announcing interruption in services or just information about upcoming events). These tools typically allow administrators (operators) to send "targeted" messages which are sent only to specific groups of users or computers, e/g only those located in a specified building or connected to a particular computing service. CERN has a long history of such tools: CERNVMS€™s SPM_quotMESSAGE command, Zephyr and the most recent the NICE Alerter based on the NNTP protocol. The NICE Alerter used on all Windows-based computers had to be phased out as a consequence of phasing out NNTP at CERN. The new solution to broadcast information messages on the CERN campus continues to provide the service based on cross-platform technologies, hence minimizing custom developments and relying on commercial software as much as possible. The new system, called CERN Alerter, is based on RSS (Really Simpl...

  11. V-Alert: Description and Validation of a Vulnerable Road User Alert System in the Framework of a Smart City.

    Science.gov (United States)

    Hernandez-Jayo, Unai; De-la-Iglesia, Idoia; Perez, Jagoba

    2015-07-29

    V-Alert is a cooperative application to be deployed in the frame of Smart Cities with the aim of reducing the probability of accidents involving Vulnerable Road Users (VRU) and vehicles. The architecture of V-Alert combines short- and long-range communication technologies in order to provide more time to the drivers and VRU to take the appropriate maneuver and avoid a possible collision. The information generated by mobile sensors (vehicles and cyclists) is sent over this heterogeneous communication architecture and processed in a central server, the Drivers Cloud, which is in charge of generating the messages that are shown on the drivers' and cyclists' Human Machine Interface (HMI). First of all, V-Alert has been tested in a simulated scenario to check the communications architecture in a complex scenario and, once it was validated, all the elements of V-Alert have been moved to a real scenario to check the application reliability. All the results are shown along the length of this paper.

  12. Auditory alert systems with enhanced detectability

    Science.gov (United States)

    Begault, Durand R. (Inventor)

    2008-01-01

    Methods and systems for distinguishing an auditory alert signal from a background of one or more non-alert signals. In a first embodiment, a prefix signal, associated with an existing alert signal, is provided that has a signal component in each of three or more selected frequency ranges, with each signal component in each of three or more selected level at least 3-10 dB above an estimated background (non-alert) level in that frequency range. The alert signal may be chirped within one or more frequency bands. In another embodiment, an alert signal moves, continuously or discontinuously, from one location to another over a short time interval, introducing a perceived spatial modulation or jitter. In another embodiment, a weighted sum of background signals adjacent to each ear is formed, and the weighted sum is delivered to each ear as a uniform background; a distinguishable alert signal is presented on top of this weighted sum signal at one ear, or distinguishable first and second alert signals are presented at two ears of a subject.

  13. 47 CFR 80.1111 - Distress alerting.

    Science.gov (United States)

    2010-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Global Maritime Distress and Safety System (GMDSS) Operating Procedures for Distress and Safety Communications § 80.1111 Distress alerting. (a) The transmission of a distress alert indicates...

  14. 21 CFR 26.20 - Alert system.

    Science.gov (United States)

    2010-04-01

    ... PHARMACEUTICAL GOOD MANUFACTURING PRACTICE REPORTS, MEDICAL DEVICE QUALITY SYSTEM AUDIT REPORTS, AND CERTAIN... Provisions for Pharmaceutical Good Manufacturing Practices § 26.20 Alert system. (a) The details of an alert... concerning quality, which could necessitate additional controls or suspension of the distribution of the...

  15. 太阳能辅助地源热泵供暖实验研究%Experimental study of a solar assisted ground source heat pump for heating

    Institute of Scientific and Technical Information of China (English)

    赵忠超; 丰威仙; 巩学梅; 米浩君; 成华; 云龙

    2014-01-01

    An experimental study is performed to determine the performance of the solar assisted ground source heat pump(SAGSHP)by using a solar-ground source heat pump hybrid system in the city of Ningbo. The result shows that comparing with the ground source heat pump(GSHP),when the ratio of solar energy to the whole en-ergy is 41. 9% ,the coefficient of performance( COP)of the heat pump and system can improve 15. 1% and 7. 7% respectively. Therefore,the solar assisted ground source heat pump has a significant performance advan-tage according to the experimental result.%选取宁波某公用建筑的太阳能-地源热泵复合系统为实验系统,对太阳能辅助地源热泵( solar assisted ground source heat pump,SAGSHP)供暖进行了实验研究.研究结果表明:与单一的地源热泵(ground source heat pump,GSHP)相比,当太阳能承担41.9%负荷时,热泵机组和整个系统的能效比(coefficient of performance,COP)分别提高了15.1%和7.7%, SAGSHP 供暖运行模式具有明显的性能优势.

  16. Evaluation of Visual Alerts in the Maritime Domain

    National Research Council Canada - National Science Library

    Roberts, Shelley; Foster-Hunt, Tara

    2008-01-01

    .... As the auditory modality is overloaded in the current alerting system, one method of potentially reducing perceptual overload is to replace auditory alerts with alerts presented in the visual domain...

  17. Shallow Groundwater Temperatures and the Urban Heat Island Effect: the First U.K City-wide Geothermal Map to Support Development of Ground Source Heating Systems Strategy

    Science.gov (United States)

    Patton, Ashley M.; Farr, Gareth J.; Boon, David P.; James, David R.; Williams, Bernard; Newell, Andrew J.

    2015-04-01

    The first UK city-wide heat map is described based on measurements of groundwater from a shallow superficial aquifer in the coastal city of Cardiff, Wales, UK. The UK Government has a target of reducing greenhouse gas emissions by 80% by 2050 (Climate Change Act 2008) and low carbon technologies are key to achieving this. To support the use of ground source heating we characterised the shallow heat potential of an urban aquifer to produce a baseline dataset which is intended to be used as a tool to inform developers and to underpin planning and regulation. We exploited an existing network of 168 groundwater monitoring boreholes across the city, recording the water temperature in each borehole at 1m depth intervals up to a depth of 20m. We recorded groundwater temperatures during the coldest part of 2014, and repeat profiling of the boreholes in different seasons has added a fourth dimension to our results and allowed us to characterise the maximum depth of seasonal temperature fluctuation. The temperature profiles were used to create a 3D model of heat potential within the aquifer using GOCAD® and the average borehole temperatures were contoured using Surfer® 10 to generate a 2D thermal resource map to support future assessment of urban Ground Source Heat Pumps prospectively. The average groundwater temperature in Cardiff was found to be above the average for England and Wales (11.3°C) with 90% of boreholes in excess of this figure by up to 4°C. The subsurface temperature profiles were also found to be higher than forecast by the predicted geothermal gradient for the area. Potential sources for heat include: conduction from buildings, basements and sub-surface infrastructure; insulation effects of the urban area and of the geology, and convection from leaking sewers. Other factors include recharge inhibition by drains, localised confinement and rock-water interaction in specific geology. It is likely to be a combination of multiple factors which we are hoping

  18. Soil Thermal Balance Analysis for a Ground Source Heat Pump System in a Hot-Summer and Cold-Winter Region

    Directory of Open Access Journals (Sweden)

    Zhongchao Zhao

    2018-05-01

    Full Text Available As a renewable and high energy efficiency technology providing air conditioning and domestic hot water, the ground source heat pump system (GSHPS has been extensively used worldwide in recent years. Compared with conventional systems, GSHPSs with heat recovery reject less heat into the soil and extract more heat from it, which can help reduce soil thermal imbalance in hot-summer and cold-winter regions. In this paper, conventional GSHPS, and GSHPS with different heat recovery ratios, in a typical city were compared based on thermal imbalance ratios, average soil temperatures and soil temperature increases. The transient system simulation software was used to simulate the operation performance of GSHPS. The thermal imbalance ratio and soil temperature decreased with increasing heat recovery ratio. After 20 years of operation, the soil thermal imbalance ratios of the GSHPS were 29.2%, 21.1%, 16%, and 5.2%, and the soil temperature rises were 8.78 °C, 5.25 °C, 3.44 °C, and 0.34 °C, while the heat recovery ratios were 0, 18%, 30% and 53%, respectively. Consequently, a GSHPS with heat recovery is a potentially efficient and economical approach for buildings in hot-summer and cold-winter regions.

  19. Land subsidence due to groundwater pumping and recharge: considering the particle-deposition effect in ground-source heat-pump engineering

    Science.gov (United States)

    Cui, Xianze; Liu, Quansheng; Zhang, Chengyuan; Huang, Yisheng; Fan, Yong; Wang, Hongxing

    2018-01-01

    With the rapid development and use of ground-source heat-pump (GSHP) systems in China, it has become imperative to research the effects of associated long-term pumping and recharge processes on ground deformation. During groundwater GSHP operation, small particles can be transported and deposited, or they can become detached in the grain skeleton and undergo recombination, possibly causing a change in the ground structure and characteristics. This paper presents a mathematical ground-deformation model that considers particle transportation and deposition in porous media based on the geological characteristics of a dual-structure stratum in Wuhan, eastern China. Thermal effects were taken into consideration because the GSHP technology used involves a device that uses heat from a shallow layer of the ground. The results reveal that particle deposition during the long-term pumping and recharge process has had an impact on ground deformation that has significantly increased over time. In addition, there is a strong correlation between the deformation change (%) and the amount of particle deposition. The position of the maximum deformation change is also the location where most of the particles are deposited, with the deformation change being as high as 43.3%. The analyses also show that flow of groundwater can have an effect on the ground deformation process, but the effect is very weak.

  20. Land subsidence due to groundwater pumping and recharge: considering the particle-deposition effect in ground-source heat-pump engineering

    Science.gov (United States)

    Cui, Xianze; Liu, Quansheng; Zhang, Chengyuan; Huang, Yisheng; Fan, Yong; Wang, Hongxing

    2018-05-01

    With the rapid development and use of ground-source heat-pump (GSHP) systems in China, it has become imperative to research the effects of associated long-term pumping and recharge processes on ground deformation. During groundwater GSHP operation, small particles can be transported and deposited, or they can become detached in the grain skeleton and undergo recombination, possibly causing a change in the ground structure and characteristics. This paper presents a mathematical ground-deformation model that considers particle transportation and deposition in porous media based on the geological characteristics of a dual-structure stratum in Wuhan, eastern China. Thermal effects were taken into consideration because the GSHP technology used involves a device that uses heat from a shallow layer of the ground. The results reveal that particle deposition during the long-term pumping and recharge process has had an impact on ground deformation that has significantly increased over time. In addition, there is a strong correlation between the deformation change (%) and the amount of particle deposition. The position of the maximum deformation change is also the location where most of the particles are deposited, with the deformation change being as high as 43.3%. The analyses also show that flow of groundwater can have an effect on the ground deformation process, but the effect is very weak.

  1. Current status of ground source heat pumps and underground thermal energy storage in Europe

    Energy Technology Data Exchange (ETDEWEB)

    Sanner, B. [Justus Liebig University, Giessen (Germany). Institute of Applied Geosciences; Karytsas, C.; Mendrinos, D. [Center for Renewable Energy Sources, Pikermi (Greece); Rybach, L. [Geowatt AG, Zurich (Switzerland)

    2003-12-01

    Geothermal Heat Pumps, or Ground Coupled Heat Pumps (GCHP), are systems combining a heat pump with a ground heat exchanger (closed loop systems), or fed by ground water from a well (open loop systems). They use the earth as a heat source when operating in heating mode, with a fluid (usually water or a water-antifreeze mixture) as the medium that transfers the heat from the earth to the evaporator of the heat pump, thus utilising geothermal energy. In cooling mode, they use the earth as a heat sink. With Borehole Heat Exchangers (BHE), geothermal heat pumps can offer both heating and cooling at virtually any location, with great flexibility to meet any demands. More than 20 years of R and D focusing on BUE in Europe has resulted in a well-established concept of sustainability for this technology, as well as sound design and installation criteria. Recent developments are the Thermal Response Test, which allows in-situ-determination of ground thermal properties for design purposes, and thermally enhanced grouting materials to reduce borehole thermal resistance. For cooling purposes, but also for the storage of solar or waste heat, the concept of underground thermal energy storage (UTES) could prove successful. Systems can be either open (aquifer storage) or can use BHE (borehole storage). Whereas cold storage is already established on the market, heat storage, and, in particular, high temperature heat storage (> 50{sup o}C) is still in the demonstration phase. Despite the fact that geothermal heat pumps have been in use for over 50 years now (the first were in the USA), market penetration of this technology is still in its infancy, with fossil fuels dominating the space heating market and air-to-air heat pumps that of space cooling. In Germany, Switzerland, Austria, Sweden, Denmark, Norway, France and the USA, large numbers of geothermal heat pumps are already operational, and installation guidelines, quality control and contractor certification are now major issues

  2. Alertness function of thalamus in conflict adaptation.

    Science.gov (United States)

    Wang, Xiangpeng; Zhao, Xiaoyue; Xue, Gui; Chen, Antao

    2016-05-15

    Conflict adaptation reflects the ability to improve current conflict resolution based on previously experienced conflict, which is crucial for our goal-directed behaviors. In recent years, the roles of alertness are attracting increasing attention when discussing the generation of conflict adaptation. However, due to the difficulty of manipulating alertness, very limited progress has been made in this line. Inspired by that color may affect alertness, we manipulated background color of experimental task and found that conflict adaptation significantly presented in gray and red backgrounds but did not in blue background. Furthermore, behavioral and functional magnetic resonance imaging results revealed that the modulation of color on conflict adaptation was implemented through changing alertness level. In particular, blue background eliminated conflict adaptation by damping the alertness regulating function of thalamus and the functional connectivity between thalamus and inferior frontal gyrus (IFG). In contrast, in gray and red backgrounds where alertness levels are typically high, the thalamus and the right IFG functioned normally and conflict adaptations were significant. Therefore, the alertness function of thalamus is determinant to conflict adaptation, and thalamus and right IFG are crucial nodes of the neural circuit subserving this ability. Present findings provide new insights into the neural mechanisms of conflict adaptation. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. A CCTV system with SMS alert (CMDSA): An implementation of pixel processing algorithm for motion detection

    Science.gov (United States)

    Rahman, Nurul Hidayah Ab; Abdullah, Nurul Azma; Hamid, Isredza Rahmi A.; Wen, Chuah Chai; Jelani, Mohamad Shafiqur Rahman Mohd

    2017-10-01

    Closed-Circuit TV (CCTV) system is one of the technologies in surveillance field to solve the problem of detection and monitoring by providing extra features such as email alert or motion detection. However, detecting and alerting the admin on CCTV system may complicate due to the complexity to integrate the main program with an external Application Programming Interface (API). In this study, pixel processing algorithm is applied due to its efficiency and SMS alert is added as an alternative solution for users who opted out email alert system or have no Internet connection. A CCTV system with SMS alert (CMDSA) was developed using evolutionary prototyping methodology. The system interface was implemented using Microsoft Visual Studio while the backend components, which are database and coding, were implemented on SQLite database and C# programming language, respectively. The main modules of CMDSA are motion detection, capturing and saving video, image processing and Short Message Service (SMS) alert functions. Subsequently, the system is able to reduce the processing time making the detection process become faster, reduce the space and memory used to run the program and alerting the system admin instantly.

  4. Field Demonstration of Ground-Source Integrated Heat Pump - Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, Van D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Munk, Jeffrey D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Gehl, Anthony C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-09-01

    Reducing energy consumption in buildings is key to reducing or limiting the negative environmental impacts from the building sector. According to the United States (U.S.) Energy Information Administration (EIA), in 2013, commercial buildings consumed 18.1 quads of primary energy, which was 18.6% of the total U.S. primary energy consumption. The primary energy consumption in the commercial sector is projected to increase by 2.8 quads from 2013 to 2040, the second largest increase after the industrial sector. Further space heating, space cooling, and ventilation (HVAC) services accounted for 31% of the energy consumption in commercial buildings. The technical objective of this project is to demonstrate the capability of the new GS-IHP system to reduce overall energy use for space heating, space cooling, and water heating by at least 45% vs. a conventional electric RTU and electric WH in a light commercial building application. This project supports the DOE-Building Technologies Office (BTO) goals of reducing HVAC energy use by 20% and water heating by 60% by 2030.

  5. The Strategic Exercise of Options Using Government Subsidies: An Analysis of Production Subsidies for the Ground Source Heat Pump

    Science.gov (United States)

    Lin, Sheng-Hau; Li, Jia-Hsun; Hsu, Chih-Chen; Hsieh, Jing-Chzi; Liao, Pin-Chao

    2018-04-01

    This study utilizes consolidation investment theory to incorporate with business strategies and government subsidy to develop a strategic exercise of options model. This empirical investigation examines the ground source heat pump (GSHP) government subsidy program, which is part of China’s 12th Five Year Plan. The developed model is applied to explain the behaviours of business investment with regard to strategic investment timing, option values, and the influence of government subsidies in duopolistic real-world investment decisions. The results indicate that subsidy policy can reduce the differences of investment timing among GSHP investors and has clearly evidenced the positive benefit–cost ratio of government subsidy, which facilitates China’s GSHP industry development.

  6. Technical Feasibility Study for Deployment of Ground-Source Heat Pump Systems: Portsmouth Naval Shipyard -- Kittery, Maine

    Energy Technology Data Exchange (ETDEWEB)

    Hillesheim, M.; Mosey, G.

    2014-11-01

    The U.S. Environmental Protection Agency (EPA) Office of Solid Waste and Emergency Response, in accordance with the RE-Powering America's Lands initiative, engaged the U.S. Department of Energy's (DOE) National Renewable Energy Laboratory (NREL) to conduct feasibility studies to assess the viability of developing renewable energy generating facilities on contaminated sites. Portsmouth Naval Shipyard (PNSY) is a United States Navy facility located on a series of conjoined islands in the Piscataqua River between Kittery, ME and Portsmouth, NH. EPA engaged NREL to conduct a study to determine technical feasibility of deploying ground-source heat pump systems to help PNSY achieve energy reduction goals.

  7. Annual investigation of vertical type ground source heat pump system performance on a wall heating and cooling system in Istanbul

    Energy Technology Data Exchange (ETDEWEB)

    Akbulut, U.; Yoru, Y.; Kincay, O. [Department of Mechanical Engineering, Yildiz Technical University (Turkey)], email: akbulutugur@yahoo.com, email: yilmazyoru@gmail.com, email: okincay@yildiz.edu.tr

    2011-07-01

    Wall heating and cooling systems (WHCS) are equipped with heating serpentines or panels for water circulation. These systems operate in a low temperature range so they are preferable to other, conventional systems. Furthermore, when these systems are connected to a ground source heat pump (GSHP) system, energy performance and thermal comfort are further enhanced. The purpose of this paper is to report the results of an annual inspection done on a vertical type ground-coupled heat pump systems (V-GSHP) WHCS in Istanbul and present the results. The performance data from the Yildiz Renewable Energy House at Davutpasa Campus of Yildiz Technical University, Istanbul, Turkey, during the year 2010 were collected and analyzed. The conclusions drawn from the inspection and analysis were listed in this paper. Using renewable energy sources effectively will bring both economic and environmental benefits and it is hoped that the use of these energy efficient WHCS systems will become widespread.

  8. Estimating the CO2 mitigation potential of horizontal Ground Source Heat Pumps in the UK

    Science.gov (United States)

    Garcia-Gonzalez, R.; Verhoef, A.; Vidale, P. L.; Gan, G.; Chong, A.; Clark, D.

    2012-04-01

    By 2020, the UK will need to generate 15% of its energy from renewables to meet our contribution to the EU renewable energy target. Heating and cooling systems of buildings account for 30%-50% of the global energy consumption; thus, alternative low-carbon technologies such as horizontal Ground Couple Heat Pumps (GCHPs) can contribute to the reduction of anthropogenic CO2 emissions. Horizontal GCHPs currently represent a small fraction of the total energy generation in the UK. However, the fact that semi-detached and detached dwellings represent approximately 40% of the total housing stocks in the UK could make the widespread implementation of this technology particularly attractive in the UK and so could significantly increase its renewable energy generation potential. Using a simulation model, we analysed the dynamic interactions between the environment, the horizontal GCHP heat exchanger and typical UK dwellings, as well as their combined effect on heat pump performance and CO2 mitigation potential. For this purpose, a land surface model (JULES, Joint UK Land Environment Simulator), which calculates coupled soil heat and water fluxes, was combined with a heat extraction model. The analyses took into account the spatio-temporal variability of soil properties (thermal and hydraulic) and meteorological variables, as well as different horizontal GCHP configurations and a variety of building loads and heat demands. Sensitivity tests were performed for four sites in the UK with different climate and soil properties. Our results show that an installation depth of 1.0m would give us higher heat extractions rates, however it would be preferable to install the pipes slightly deeper to avoid the seasonal influence of variable meteorological conditions. A value of 1.5m for the spacing between coils (S) for a slinky configuration type is recommended to avoid thermal disturbances between neighbouring coils. We also found that for larger values of the spacing between the coils

  9. 太阳能与地源热泵联合温室大棚系统的设计%System design of solar greenhouses combined with ground source heat pump

    Institute of Scientific and Technical Information of China (English)

    苏伟; 穆青; 董继先; 王彬权

    2015-01-01

    Greenhouse is an irreplaceable technology in modern agriculture, but it was easily affected by weather. The combination of solar energy-ground source heat pump system can make full use of the complementary advantages of both of them.It confirmed the stable operation of greenhouses all year round.Therefore, a solar greenhouse com-bined with ground source heat pump system and the PLC control circuit of the system were designed, and the brief a-nalysis on the feasibility was carried out.It also provides certain reference and suggestion about subsequent applica-tion of the greenhouses combined with solar energy and ground source heat pump system.%温室大棚是现代农业中不可替代的技术,但其受天气影响比较大,采用太阳能—地源热泵联合系统作业的方式,可充分利用二者的优势,使得温室大棚一年四季稳定运行。为此,设计了太阳能与地源热泵联合温室大棚系统及该系统的PLC控制回路,并对其可行性进行了简要分析,可为后续太阳能—地源热泵联合系统在温室大棚中的应用提供参考。

  10. Simulation of a combined heating, cooling and domestic hot water system based on ground source absorption heat pump

    International Nuclear Information System (INIS)

    Wu, Wei; You, Tian; Wang, Baolong; Shi, Wenxing; Li, Xianting

    2014-01-01

    Highlights: • A combined heating/cooling/DHW system based on GSAHP is proposed in cold regions. • The soil imbalance is effectively reduced and soil temperature can be kept stable. • 20% and 15% of condensation/absorption heat is recovered by GSAHP to produce DHW. • The combined system can improve the primary energy efficiency by 23.6% and 44.4%. - Abstract: The amount of energy used for heating and domestic hot water (DHW) is very high and will keep increasing. The conventional ground source electrical heat pump used in heating-dominated buildings has the problems of thermal imbalance, decrease of soil temperature, and deterioration of heating performance. Ground source absorption heat pump (GSAHP) is advantageous in both imbalance reduction and primary energy efficiency (PEE) improvement; however, the imbalance is still unacceptable in the warmer parts of cold regions. A combined heating/cooling/DHW (HCD) system based on GSAHP is proposed to overcome this problem. The GSAHPs using generator absorber heat exchange (GAX) and single-effect (SE) cycles are simulated to obtain the performance under various working conditions. Different HCD systems in Beijing and Shenyang are simulated comparatively in TRNSYS, based on which the thermal imbalance, soil temperature, heat recovery, and energy efficiency are analyzed. Results show that GSAHP–GAX–HCD is suitable for Beijing and GSAHP–SE–HCD is suitable for Shenyang. The imbalance ratio can be reduced to −14.8% in Beijing and to 6.0% in Shenyang with an annual soil temperature variation of only 0.5 °C and 0.1 °C. Furthermore, about 20% and 15% of the total condensation/absorption heat is recovered to produce DHW, and the PEE can reach 1.516 in Beijing and 1.163 in Shenyang. The combined HCD systems can achieve a PEE improvement of 23.6% and 44.4% compared with the normal heating/cooling systems

  11. Thermal performance and pressure drop of spiral-tube ground heat exchangers for ground-source heat pump

    International Nuclear Information System (INIS)

    Jalaluddin; Miyara, Akio

    2015-01-01

    Thermal performance and pressure drop of the spiral-tube GHE were evaluated in this present work. A numerical simulation tool was used to carry out this research. The heat exchange rates per meter borehole depth of the spiral-tube GHE with various pitches and their pressure drops were compared with that of the U-tube GHE. Furthermore, a comparative analysis between a spiral pipe and straight pipe was performed. In comparison with the straight pipe, using the spiral pipe in the borehole increased the heat exchange rate to the ground per meter borehole depth. However, the pressure drop of water flow also increased due to increasing the length of pipe per meter borehole depth and its spiral geometry. The accuracy of the numerical model was verified for its pressure drop with some pressure drop correlations. The heat exchange rate and pressure drop of the GHEs are presented. As an example, the heat exchange rate per meter borehole depth of spiral pipe with 0.05 m pitch in the turbulent flow increased of 1.5 times. Its pressure drop also increased of 6 times. However, from the view point of energy efficiency, using the spiral pipe in the ground-source heat pump system gives a better performance than using the straight pipe. The heat exchange rate and pressure drop are important parameter in design of the ground-source heat pump (GSHP) system. - Highlights: • Thermal performance and pressure drop of spiral-tube GHE are presented. • Effects of spiral pitch on thermal performance and pressure drop are analyzed. • Using a spiral pipe increases heat exchange rate per meter borehole depth of GHE. • Pressure drop per meter borehole depth also increases in the spiral pipe.

  12. Solar radiation alert system : final report.

    Science.gov (United States)

    2009-03-01

    The Solar Radiation Alert (SRA) system continuously evaluates measurements of high-energy protons made by instruments on GOES satellites. If the measurements indicate a substantial elevation of effective dose rates at aircraft flight altitudes, the C...

  13. Radiation Alert Immediate Disclosure, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Invocon's Radiation Alert Immediate Disclosure (RAID) system is a miniature, low-power, real-time, active radiation badge. It is designed for monitoring personnel,...

  14. Sounding the Alert: Designing an Effective Voice for Earthquake Early Warning

    Science.gov (United States)

    Burkett, E. R.; Given, D. D.

    2015-12-01

    The USGS is working with partners to develop the ShakeAlert Earthquake Early Warning (EEW) system (http://pubs.usgs.gov/fs/2014/3083/) to protect life and property along the U.S. West Coast, where the highest national seismic hazard is concentrated. EEW sends an alert that shaking from an earthquake is on its way (in seconds to tens of seconds) to allow recipients or automated systems to take appropriate actions at their location to protect themselves and/or sensitive equipment. ShakeAlert is transitioning toward a production prototype phase in which test users might begin testing applications of the technology. While a subset of uses will be automated (e.g., opening fire house doors), other applications will alert individuals by radio or cellphone notifications and require behavioral decisions to protect themselves (e.g., "Drop, Cover, Hold On"). The project needs to select and move forward with a consistent alert sound to be widely and quickly recognized as an earthquake alert. In this study we combine EEW science and capabilities with an understanding of human behavior from the social and psychological sciences to provide insight toward the design of effective sounds to help best motivate proper action by alert recipients. We present a review of existing research and literature, compiled as considerations and recommendations for alert sound characteristics optimized for EEW. We do not yet address wording of an audible message about the earthquake (e.g., intensity and timing until arrival of shaking or possible actions), although it will be a future component to accompany the sound. We consider pitch(es), loudness, rhythm, tempo, duration, and harmony. Important behavioral responses to sound to take into account include that people respond to discordant sounds with anxiety, can be calmed by harmony and softness, and are innately alerted by loud and abrupt sounds, although levels high enough to be auditory stressors can negatively impact human judgment.

  15. Gérer et alerter

    Directory of Open Access Journals (Sweden)

    Valérie November

    2009-03-01

    Full Text Available Sur la base de deux événements d’inondation ayant touché récemment, dans des contextes politiques, organisationnels et hydrologiques bien différents, de nouveaux quartiers d’habitation, cet article rend compte des pratiques des acteurs impliqués dans des situations d’alerte et de crise en Suisse. Le recensement des acteurs – à travers leur rôle et leur place dans les mécanismes de préparation, d’alerte et de gestion –, ainsi que l’inventaire des documents mobilisés par ceux-ci, ont été réalisés dans les deux cas. Cette analyse a permis d’évaluer la gestion des événements, de déceler les changements organisationnels qui ont suivi les crises et de connaître la conception et le degré de formalisation du risque dont étaient dotés les différents acteurs avant et après les inondations. Plus encore, l’analyse a documenté les nouveaux processus d’alerte et de prévision qui ont été mis en place suite aux événements. Il s’avère ainsi que les épisodes d’inondation agissent de façon décisive sur la production de connaissances, à un degré variable selon les acteurs. Ces épisodes révèlent aussi parfois l’existence de connaissances « en attente » qui ne sont pas encore intégrées dans les procédures institutionnelles. Tant du point de vue de la prévision que de la gestion de la crise, ils permettent aussi de tester les canaux de l’information et de combler les déficits d’organisation, de collaboration et de sécurisation des dispositifs de communication. En outre, les risques et les crises liés aux inondations modifient les dynamiques et les politiques territoriales, conséquences du réajustement des réseaux d’acteurs. La mise en place de dispositifs d’intervention et de gestion de crise se montre cependant plus efficace que la refonte des dispositifs d’aménagement, généralement longue. Toutefois, la mémoire des événements se dégradant avec le temps, une inscription

  16. Radon as a tracer to characterize the interactions between groundwater and surface water around the ground source heat pump system in riverside area

    Science.gov (United States)

    Kim, Jaeyeon; Lee, Seong-Sun; Lee, Kang-Kun

    2016-04-01

    The interaction characteristics between groundwater and surface water was examined by using Radon-222 at Han River Environmental Research Center (HRERC) in Korea where a geothermal resource using indirect open loop ground source heat pump (GSHP) has been developed. For designing a high efficiency performance of the open loop system in shallow aquifer, the riverside area was selected for great advantage of full capacity of well. From this reason groundwater properties of the study site can be easily influenced by influx of surrounding Han River. Therefore, 12 groundwater wells were used for monitoring radon concentration and groundwater level with fluctuation of river stage from May, 2014 to Apr., 2015. The short term monitoring data showed that the radon concentration was changed in accordance with flow meter data which was reflected well by the river stage fluctuation. The spatial distribution of radon concentration from long term monitoring data was also found to be affected by water level fluctuation by nearby dam activity and seasonal effect such as heavy rainfall and groundwater pumping. The estimated residence time indicates that river flows to the study site change its direction according to the combined effect of river stage and groundwater hydrology. In the linear regression of the values, flow velocities were yielded around 0.04 to 0.25 m/day which were similar to flow meter data. These results reveal that Radon-222 can be used as an appropriate environmental tracer in examining the characteristics of interaction in consideration of fluctuating river flow on operation of GSHP in the riverside area. ACKNOWLEDGEMENT This work was supported by the research project of "Advanced Technology for Groundwater Development and Application in Riversides (Geowater+) in "Water Resources Management Program (code 11 Technology Innovation C05)" of the MOLIT and the KAIA in Korea.

  17. Designing a Free Academic Early Alert System

    Directory of Open Access Journals (Sweden)

    Adam C Welch

    2016-10-01

    Full Text Available This manuscript describes the development and implementation of a cloud-based, academic early alert system using Google Sheets. It was written for a non-computer savvy person to be able to develop the early alert system. By creating a Master Sheet and using the syntax from the share function of Google Sheets, a unique sheet can be created for each advisor that limits information sharing of their specific advisees. By adding a Google Form to the sheet, advisor interventions can be captured that reflect interventions made as a result of the early alert sheet. Approximately 52% of students were identified on the early alert sheet by having at least one non-passing score on an exam. There were 35-50% of faculty advisors who documented their interventions in the sheet. The template and coding used to develop this academic early alert sheet may be applied to other central documentation needs, such as professionalism early alert. Conflict of Interest Dr. Welch reports owning stock in Alphabet, Inc, however, was not involved in the selection of Google as the preferred platform at this institution.   Type: Note

  18. Impact of e-alert systems on the care of patients with acute kidney injury.

    Science.gov (United States)

    Breighner, Crystal M; Kashani, Kianoush B

    2017-09-01

    With the recent advancement in electronic health record systems and meaningful use of information technology incentive programs (i.e., the American Recovery and Reinvestment Act, the Health Information Technology for Economic and Clinical Health Act, and the Centers for Medicare & Medicaid Services), interest in clinical decision support systems has risen. These systems have been used to examine a variety of different syndromes with variable reported effects. In recent years, electronic alerts (e-alerts) have been implemented at various institutions to decrease the morbidity associated with acute kidney injury (AKI). AKI is common, accounting for 1 in 7 hospital admissions, and is associated with increased length of hospital stay and mortality. AKI is often underrecognized, causing delayed intervention. The use of e-alerts may result in earlier recognition and intervention, as well as decreased morbidity and mortality. This must be balanced with the possibility of increased resource utilization that e-alerts may cause. Before widespread implementation, the ethical and legal consequences of not following e-alert recommendations must be established, and the optimal algorithm for AKI e-alert detection must be determined. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. IP telephony based danger alert communication system and its implementation

    Science.gov (United States)

    Rezac, Filip; Safarik, Jakub; Voznak, Miroslav; Tomala, Karel; Partila, Pavol

    2013-05-01

    This article discusses a danger alert system created as a part of the research project at Department of Telecommunications of Technical University of Ostrava. The aim of the system is to distribute pre-recorded voice messages in order to alert the called party in danger. This article describes individual technologies, which the application uses for its operation as well as issues relating to hardware requirements and transfer line bandwidth load. The article also describes new algorithms, which had to be developed in order to ensure the reliability of the system. Our intent is focused on disaster management, the message, which should be delivered within specified time span, is typed in the application and text-to-speech module ensures its transformation to a speech format, after that a particular scenario or warned area is selected and a target group is automatically unloaded. For this purpose, we have defined XML format for delivery of phone numbers which are located in the target area and these numbers are obtained from mobile BTS's (Base transmission stations). The benefit of such communication compared to others, is the fact, that it uses a phone call and, therefore, it is possible to get feedback who accepted the message and to improve efficiency of alert system. Finally, the list of unanswered calls is exported and these users can be informed via SMS.

  20. 47 CFR 80.277 - Ship Security Alert System (SSAS).

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Ship Security Alert System (SSAS). 80.277... Security Alert System (SSAS). (a) Vessels equipped with a Ship Security Alert System pursuant to the Safety..., “RTCM Standard 11020.0—Ship Security Alert Systems (SSAS) using the Cospas-Sarsat System,” Version 1.0...

  1. Alert system for students with visual disabilities at the UTM

    Directory of Open Access Journals (Sweden)

    Marely del Rosario Cruz Felipe

    2018-01-01

    Full Text Available In the transfer of students with visual disabilities at the Technical University of Manabí (UTM accidents have been reported when going through some ramps and other obstacles, especially on rainy days. This article belongs to an investigation into the realization of an alert system for students with visual disabilities. The objective of the implementation of this system is to guide students with visual disabilities on different obstacles that exist in their transfer through the university. To carry out the implementation of this system, the alert systems and the technologies that are currently used as a result of a recording studio in the national and international scope were analyzed, the tools and technologies used in the developed solution are described. (Definition, technologies for the change of people, software, programming languages, etc. that allowed an efficient implementation in a short time of the proposed system by means of RFID (Radio Frequency Identification technology. The above is reflected in the positive orientation for the transfer of 32 students with visual disabilities through the university and by those who have contributed to improving their quality of life.

  2. A study of Ground Source Heat Pump based on a heat infiltrates coupling model established with FEFLOW

    Science.gov (United States)

    Chen, H.; Hu, C.; Chen, G.; Zhang, Q.

    2017-12-01

    Geothermal heat is a viable source of energy and its environmental impact in terms of CO2 emissions is significantly lower than conventional fossil fuels. it is vital that engineers acquire a proper understanding about the Ground Source Heat Pump (GSHP). In this study, the model of the borehole exchanger under conduction manners and heat infiltrates coupling manners was established with FEFLOW. The energy efficiency, heat transfer endurance and heat transfer in the unit depth were introduced to quantify the energy efficient and the endurance period. The performance of a the Borehole Exchanger (BHE) in soil with and without groundwater seepage was analyzed of heat transfer process between the soil and the working fluid. Basing on the model, the varied regularity of energy efficiency performance an heat transfer endurance with the conditions including the different configuration of the BHE, the soil properties, thermal load characteristic were discussed. Focus on the heat transfer process in multi-layer soil which one layer exist groundwater flow. And an investigation about thermal dispersivity was also analyzed its influence on heat transfer performance. The final result proves that the model of heat infiltrates coupling model established in this context is reasonable, which can be applied to engineering design.

  3. Fundamental study on airborne electromagnetic survey using grounded source; Chihyo source gata kuchu denji tansa no kisoteki kenkyu. 2

    Energy Technology Data Exchange (ETDEWEB)

    Mogi, T; Fujimitsu, Y [Kyushu University, Fukuoka (Japan). Faculty of Engineering; Tanaka, Y [Kyoto University, Kyoto (Japan). Faculty of Science; Jomori, N [Chiba Electronics Research Institute, Chiba (Japan); Morikawa, T [Dowa Engineering Co. Ltd., Okayama (Japan); Kusunoki, K [Central Research Institute of Electric Power Industry, Tokyo (Japan)

    1997-05-27

    With an objective to develop an airborne electromagnetic survey method for greater depths achievable of exploration, a discussion was given on an exploration method of a type in which a transmitting device is placed on the ground to receive signals in an atmosphere. A prototype exploration apparatus is mounted with a fluxgate magnetometer, an attitude meter, a GPS, and a battery. This exploration apparatus is suspended on a 30 meter long rope from a helicopter to perform the exploration. Two flight tests on this apparatus were carried out in the Unzen area, Nagasaki Prefecture and the Motomiya area, Wakayama Prefecture. The ground source was extended to a distance of 1.5 km, and a current of about 20 A was flown with a quiescent wave having four-second cycles. The helicopter flew nearly horizontally at a ground speed of about 50 km, a flight altitude of 450 m above sea level, and a terrain clearances of 100 to 400 m. The obtained data had variations in correspondence with changes in roll and pitch angles, whereas the variation of about 5000 nT was reduced to about 1000 nT as a result of correction. It was not possible, however, to correct completely the variation with short cycles, requiring further discussions on frequency characteristics of the magnetometer. 6 figs., 1 tab.

  4. Predicting performance of a ground-source heat pump system using fuzzy weighted pre-processing-based ANFIS

    Energy Technology Data Exchange (ETDEWEB)

    Esen, Hikmet; Esen, Mehmet [Department of Mechanical Education, Faculty of Technical Education, Firat University, 23119 Elazig (Turkey); Inalli, Mustafa [Department of Mechanical Engineering, Faculty of Engineering, Firat University, 23279 Elazig (Turkey); Sengur, Abdulkadir [Department of Electronic and Computer Science, Faculty of Technical Education, Firat University, 23119 Elazig (Turkey)

    2008-12-15

    The goal of this work is to predict the daily performance (COP) of a ground-source heat pump (GSHP) system with the minimum data set based on an adaptive neuro-fuzzy inference system (ANFIS) with a fuzzy weighted pre-processing (FWP) method. To evaluate the effectiveness of our proposal (FWP-ANFIS), a computer simulation is developed on MATLAB environment. The comparison of the proposed hybridized system's results with the standard ANFIS results is carried out and the results are given in the tables. The efficiency of the proposed method was demonstrated by using the 3-fold cross-validation test. The statistical methods, such as the root-mean squared (RMS), the coefficient of multiple determinations (R{sup 2}) and the coefficient of variation (cov), are given to compare the predicted and actual values for model validation. The average R{sup 2} values is 0.9998, the average RMS value is 0.0272 and the average cov value is 0.7733, which can be considered as very promising. The data set for the COP of GSHP system available included 38 data patterns. The simulation results show that the FWP-based ANFIS can be used in an alternative way in these systems. The prediction results of the proposed structure were much better than the standard ANFIS results. Therefore, instead of limited experimental data found in the literature, faster and simpler solutions are obtained using hybridized structures such as FWP-based ANFIS. (author)

  5. Real time alert system: a disease management system leveraging health information exchange.

    Science.gov (United States)

    Anand, Vibha; Sheley, Meena E; Xu, Shawn; Downs, Stephen M

    2012-01-01

    Rates of preventive and disease management services can be improved by providing automated alerts and reminders to primary care providers (PCPs) using of health information technology (HIT) tools. Using Adaptive Turnaround Documents (ATAD), an existing Health Information Exchange (HIE) infrastructure and office fax machines, we developed a Real Time Alert (RTA) system. RTA is a computerized decision support system (CDSS) that is able to deliver alerts to PCPs statewide for recommended services around the time of the patient visit. RTA is also able to capture structured clinical data from providers using existing fax technology. In this study, we evaluate RTA's performance for alerting PCPs when their patients with asthma have an emergency room visit anywhere in the state. Our results show that RTA was successfully able to deliver "just in time" patient-relevant alerts to PCPs across the state. Furthermore, of those ATADs faxed back and automatically interpreted by the RTA system, 35% reported finding the provided information helpful. The PCPs who reported finding information helpful also reported making a phone call, sending a letter or seeing the patient for follow up care. We have successfully demonstrated the feasibility of electronically exchanging important patient related information with the PCPs statewide. This is despite a lack of a link with their electronic health records. We have shown that using our ATAD technology, a PCP can be notified quickly of an important event such as a patient's asthma related emergency room admission so further follow up can happen in near real time.

  6. Designing a Free Academic Early Alert System

    OpenAIRE

    Adam C Welch; Adam Greever; Carmen Linne

    2016-01-01

    This manuscript describes the development and implementation of a cloud-based, academic early alert system using Google Sheets. It was written for a non-computer savvy person to be able to develop the early alert system. By creating a Master Sheet and using the syntax from the share function of Google Sheets, a unique sheet can be created for each advisor that limits information sharing of their specific advisees. By adding a Google Form to the sheet, advisor interventions can be captured tha...

  7. A model predictive framework of Ground Source Heat Pump coupled with Aquifer Thermal Energy Storage System in heating and cooling equipment of a building

    NARCIS (Netherlands)

    Rostampour Samarin, V.; Bloemendal, J.M.; Keviczky, T.

    2017-01-01

    This paper presents a complete model of a building heating and cooling equipment and a ground source heat pump (GSHP) coupled with an aquifer thermal energy storage (ATES) system. This model contains detailed
    mathematical representations of building thermal dynamics, ATES system dynamics, heat

  8. Quantification of exploitable shallow geothermal energy by using Borehole Heat Exchanger coupled Ground Source Heat Pump systems

    International Nuclear Information System (INIS)

    Hein, Philipp; Zhu, Ke; Bucher, Anke; Kolditz, Olaf; Pang, Zhonghe; Shao, Haibing

    2016-01-01

    Highlights: • The amount of technically exploitable shallow geothermal energy was quantified. • Therefore, a comprehensive numerical borehole heat exchanger model was employed. • The concept of equivalent temperature drop is introduced. • For one BHE, an equivalent temperature drop of 1.8–2.8 °C over 30 years is realistic • The average extractable energy amount evaluates to be 3.5–5.4 kW h m"−"2 a"−"1. - Abstract: In previous studies, the amount of exploitable shallow geothermal energy was estimated by assuming a uniform temperature drop of 2–6 °C in the aquifer. In this work, a more comprehensive numerical model has been employed to evaluate the available amount of shallow geothermal energy by using Borehole Heat Exchanger coupled Ground Source Heat Pump systems. Numerical experiments have been performed by simulating the long-term evolution of the subsurface temperature field, which is subject to the operation of borehole heat exchangers and varying parameters like subsurface thermal conductivity and groundwater flow velocity. The concept of equivalent temperature drop is proposed as an auxiliary quantity for the subsurface. With the help of this parameter, a procedure has been established to quantify the amount of shallow geothermal potential. Following this approach, a realistic equivalent temperature reduction is found to be from −1.8 to −4.4 °C in the subsurface over a period of 30 years. This can be translated to an annual extractable geothermal energy value in a unit surface area, and it ranges from 3.5 to 8.6 kW h m"−"2 a"−"1. The exact value is site specific and heavily depends on the soil thermal conductivity, groundwater velocity, and borehole arrangement.

  9. [Health alert management and emerging risk].

    Science.gov (United States)

    Pillonel, J

    2010-12-01

    Following health crisis that have occurred in the nineties (contaminated blood, mad cow, asbestos, etc.) and more recently those generated by the heat wave in 2003 or by emerging infectious pathogens (SARS, West Nile, Chikungunya, H5N1, H1N1…), a real health vigilance system has been progressively developed in France. After a brief historical overview of the health alert system, this article will give the guiding principles of its current organization in France and will present two examples of recent health alerts (Chikungunya in the Reunion Island in 2005-2006 and hepatitis A outbreak in the Côtes-d'Armor in August 2007), that have needed the implementation of preventive measures regarding the blood donor selection. These two examples have shown that the position of the alert in the French health vigilance system needs to be very close to the event. In that case, health alert is a very useful tool for decision making especially when measures have to be taken to prevent transfusion-transmitted pathogens. Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  10. Understanding the context of network traffic alerts

    NARCIS (Netherlands)

    Cappers, B.C.M.; van Wijk, J.J.; Best, D.M.; Staheli, D.; Prigent, N.; Engle, S.; Harrison, L.

    2016-01-01

    For the protection of critical infrastructures against complex virus attacks, automated network traffic analysis and deep packet inspection are unavoidable. However, even with the use of network intrusion detection systems, the number of alerts is still too large to analyze manually. In addition,

  11. CEI-PEA Alert, Summer 2006

    Science.gov (United States)

    Center for Educational Innovation - Public Education Association, 2006

    2006-01-01

    The "CEI-PEA Alert" is an advocacy newsletter that deals with topics of interest to all concerned with the New York City public schools. This issue includes: (1) Practical Skills & High Academic Standards: Career Technical Education; (2) Parents: Help Your Children Gain "Soft Skills" for the Workforce; (3) Culinary Arts…

  12. IR panoramic alerting sensor concepts and applications

    Science.gov (United States)

    de Jong, Arie N.; Schwering, Piet B. W.

    2003-09-01

    During the last decade, protection of military and civilian operational platforms against weapons like guns, grenades, missiles, Unmanned Combat Aerial (and surface) Vehicles (UCAV's) and mines, has been an issue of increased importance due to the improved kill-probability of these threats. The standard countermeasure package of armour, guns, decoys, jammers, camouflage nets and smokes is inadequate when not accompanied by a suitable sensor package, primarily consisting of an alerting device, triggering consecutive steps in the countermeasure-chain. In this process of alert four different detection techniques are considered: pre-alert, giving the directions of possible attack, detection of an action of attack, identification of the threat and finally the precise localization (3-D). The design of the alerting device is greatly depending on the platform, on which it will be used, the associated and affordable cost and the nature of the threat. A number of sensor packages, considered, developed and evaluated at TNO-FEL is presented for simple, medium size and large and expensive platforms. In recent years the requirements for these sensors have become more and more strigent due to the growing number of scenarios. The attack can practically be from any direction, implying the need for a large Field of Regard (FOR), the attack range can vary considerably and the type of threat can be very diverse, implying great flexibility and dynamic range and rapid response of the sensor. Especially the localization at short ranges is a challenging issue. Various configurations including advantages and drawbacks are discussed.

  13. 77 FR 41331 - Commercial Mobile Alert System

    Science.gov (United States)

    2012-07-13

    ... FEDERAL COMMUNICATIONS COMMISSION 47 CFR Part 10 [PS Docket No. 07-287; FCC 08-164] Commercial... with the Commission's Commercial Mobile Alert System (CMS), Second Report and Order (``CMAS Second..., for a period of three years, the information collection requirements relating to the Commercial Mobile...

  14. FACT. Flare alerts from blazar monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Dorner, Daniela [Universitaet Wuerzburg (Germany); Bretz, Thomas [RWTH Aachen (Germany); Collaboration: FACT-Collaboration

    2015-07-01

    One of the major goals of the First G-APD Cherenkov Telescope is the longterm monitoring of bright TeV blazars. For more than three years, FACT has observed the blazars Mrk 421 and Mrk 501 and a few other sources on a regular basis. To understand these highly variable objects, simultaneous data at different wavelengths are very useful. FACT is not only taking part in multi-wavelength campaigns, but also sending alerts to other instruments in case of enhanced flux, to study flares within the multi-wavelength frame. To send fast alerts, an automatic quick look analysis was set up on site. Once the data are written on disk, they are automatically processed, and the analysis results are published on a website where other observers can monitor the activity of the source in the very high energy band. In addition, alerts are sent in case the flux is higher than a certain predefined value. In 2014, more than five alerts have been sent. Results from three years of monitoring are presented.

  15. MedWatch Safety Alerts for Human Medical Products

    Data.gov (United States)

    U.S. Department of Health & Human Services — MedWatch alerts provide timely new safety information on human drugs, medical devices, vaccines and other biologics, dietary supplements, and cosmetics. The alerts...

  16. Characterization of the effects of borehole configuration and interference with long term ground temperature modelling of ground source heat pumps

    International Nuclear Information System (INIS)

    Law, Ying Lam E.; Dworkin, Seth B.

    2016-01-01

    Highlights: • Long term ground temperature response is explored using finite element methods. • Simulation method is validated against experimental and analytical data. • Temperature changes at a fast rate in the first few years and slows down gradually. • ASHRAE recommended separation distances are not always sufficient. • Thermal accumulation occurs at the centre of borehole field. - Abstract: Ground source heat pumps (GSHPs) are an environmentally friendly alternative to conventional heating and cooling systems because of their high efficiency and low greenhouse gas emissions. The ground acts as a heat sink/source for the excess/required heat inside a building for cooling and heating modes, respectively. However, imbalance in heating and cooling needs can change ground temperature over the operating duration. This increase/decrease in ground temperature lowers system efficiency and causes the ground to foul—failing to accept or provide more heat. In order to ensure that GSHPs can operate to their designed conditions, thermal modelling is required to simulate the ground temperature during system operation. In addition, the borehole field layout can have a major impact on ground temperature. In this study, four buildings were studied—a hospital, fast-food restaurant, residence, and school, each with varying borehole configurations. Boreholes were modelled in a soil volume using finite-element methods and heating and cooling fluxes were applied to the borehole walls to simulate the GSHP operation. 20 years of operation were modelled for each building for 2 × 2, 4 × 4, and 2 × 8 borehole configurations. Results indicate that the borehole separation distance of 6 m, recommended by ASHRAE, is not always sufficient to prevent borehole thermal interactions. Benefits of using a 2 × 8 configuration as opposed to a 4 × 4 configuration, which can be observed because of the larger perimeter it provides for heat to dissipate to surrounding soil were

  17. The effect of phasic auditory alerting on visual perception

    DEFF Research Database (Denmark)

    Petersen, Anders; Petersen, Annemarie Hilkjær; Bundesen, Claus

    2017-01-01

    /no-alerting design with a pure accuracy-based single-letter recognition task. Computational modeling based on Bundesen’s Theory of Visual Attention was used to examine the effect of phasic alertness on visual processing speed and threshold of conscious perception. Results show that phasic auditory alertness affects...

  18. The effect of phasic auditory alerting on visual perception.

    Science.gov (United States)

    Petersen, Anders; Petersen, Annemarie Hilkjær; Bundesen, Claus; Vangkilde, Signe; Habekost, Thomas

    2017-08-01

    Phasic alertness refers to a short-lived change in the preparatory state of the cognitive system following an alerting signal. In the present study, we examined the effect of phasic auditory alerting on distinct perceptual processes, unconfounded by motor components. We combined an alerting/no-alerting design with a pure accuracy-based single-letter recognition task. Computational modeling based on Bundesen's Theory of Visual Attention was used to examine the effect of phasic alertness on visual processing speed and threshold of conscious perception. Results show that phasic auditory alertness affects visual perception by increasing the visual processing speed and lowering the threshold of conscious perception (Experiment 1). By manipulating the intensity of the alerting cue, we further observed a positive relationship between alerting intensity and processing speed, which was not seen for the threshold of conscious perception (Experiment 2). This was replicated in a third experiment, in which pupil size was measured as a physiological marker of alertness. Results revealed that the increase in processing speed was accompanied by an increase in pupil size, substantiating the link between alertness and processing speed (Experiment 3). The implications of these results are discussed in relation to a newly developed mathematical model of the relationship between levels of alertness and the speed with which humans process visual information. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Education and Training Module in Alertness Management

    Science.gov (United States)

    Mallis, M. M.; Brandt, S. L.; Oyung, R. L.; Reduta, D. D.; Rosekind, M. R.

    2006-01-01

    The education and training module (ETM) in alertness management has now been integrated as part of the training regimen of the Pilot Proficiency Awards Program ("WINGS") of the Federal Aviation Administration. Originated and now maintained current by the Fatigue Countermeasures Group at NASA Ames Research Center, the ETM in Alertness Management is designed to give pilots the benefit of the best and most recent research on the basics of sleep physiology, the causes of fatigue, and strategies for managing alertness during flight operations. The WINGS program is an incentive program that encourages pilots at all licensing levels to participate in recurrent training, upon completion of which distinctive lapel or tie pins (wings) and certificates of completion are awarded. In addition to flight training, all WINGS applicants must attend at least one FAA-sponsored safety seminar, FAA-sanctioned safety seminar, or industry recurrent training program. The Fatigue Countermeasures Group provides an FAA-approved industry recurrent training program through an on-line General Aviation (GA) WINGS ETM in alertness management to satisfy this requirement. Since 1993, the Fatigue Countermeasures Group has translated fatigue and alertness information to operational environments by conducting two-day ETM workshops oriented primarily toward air-carrier operations subject to Part 121 of the Federal Aviation Regulations pertaining to such operations. On the basis of the information presented in the two-day ETM workshops, an ETM was created for GA pilots and was transferred to a Web-based version. To comply with the requirements of the WINGS Program, the original Web-based version has been modified to include hypertext markup language (HTML) content that makes information easily accessible, in-depth testing of alertness-management knowledge, new interactive features, and increased informational resources for GA pilots. Upon successful completion of this training module, a participant

  20. Trends in Solar energy Driven Vertical Ground Source Heat Pump Systems in Sweden - An Analysis Based on the Swedish Well Database

    Science.gov (United States)

    Juhlin, K.; Gehlin, S.

    2016-12-01

    Sweden is a world leader in developing and using vertical ground source heat pump (GSHP) technology. GSHP systems extract passively stored solar energy in the ground and the Earth's natural geothermal energy. Geothermal energy is an admitted renewable energy source in Sweden since 2007 and is the third largest renewable energy source in the country today. The Geological Survey of Sweden (SGU) is the authority in Sweden that provides open access geological data of rock, soil and groundwater for the public. All wells drilled must be registered in the SGU Well Database and it is the well driller's duty to submit registration of drilled wells.Both active and passive geothermal energy systems are in use. Large GSHP systems, with at least 20 boreholes, are active geothermal energy systems. Energy is stored in the ground which allows both comfort heating and cooling to be extracted. Active systems are therefore relevant for larger properties and industrial buildings. Since 1978 more than 600 000 wells (water wells, GSHP boreholes etc) have been registered in the Well Database, with around 20 000 new registrations per year. Of these wells an estimated 320 000 wells are registered as GSHP boreholes. The vast majority of these boreholes are single boreholes for single-family houses. The number of properties with registered vertical borehole GSHP installations amounts to approximately 243 000. Of these sites between 300-350 are large GSHP systems with at least 20 boreholes. While the increase in number of new registrations for smaller homes and households has slowed down after the rapid development in the 80's and 90's, the larger installations for commercial and industrial buildings have increased in numbers over the last ten years. This poster uses data from the SGU Well Database to quantify and analyze the trends in vertical GSHP systems reported between 1978-2015 in Sweden, with special focus on large systems. From the new aggregated data, conclusions can be drawn about

  1. Alerting, Orienting or Executive Attention Networks: Differential Patters of Pupil Dilations

    Directory of Open Access Journals (Sweden)

    Ronny eGeva

    2013-10-01

    Full Text Available Attention capacities, alerting responses, orienting to sensory stimulation, and executive monitoring of performance are considered independent yet interrelated systems. These operations play integral roles in regulating the behavior of diverse species along the evolutionary ladder. Each of the primary attention constructs—alerting, orienting, and executive monitoring— involves salient autonomic correlates as evidenced by changes in reactive pupil dilation (PD, heart rate, and skin conductance. Recent technological advances that use remote high-resolution recording may allow the discernment of temporo-spatial attributes of autonomic responses that characterize the alerting, orienting, and executive monitoring networks during free viewing, irrespective of voluntary performance. This may deepen the understanding of the roles of autonomic regulation in these mental operations and may deepen our understanding of behavioral changes in verbal as well as in non-verbal species.The aim of this study was to explore differences between psychosensory pupil dilation responses in alerting, orienting, and executive conflict monitoring tasks to generate estimates of concurrent locus coeruleus (LC noradrenergic input trajectories in healthy human adults using the attention networks test (ANT. The analysis revealed a construct-specific pattern of pupil responses: alerting is characterized by an early component (Pa, its acceleration enables covert orienting, and executive control is evidenced by a prominent late component (Pe. Pupil dilation characteristics seem to be task-sensitive, allowing exploration of mental operations irrespective of conscious voluntary responses. These data may facilitate development of studies designed to assess mental operations in diverse species using autonomic responses.

  2. Simulation of the thermal performance of a hybrid solar-assisted ground-source heat pump system in a school building

    Science.gov (United States)

    Androulakis, N. D.; Armen, K. G.; Bozis, D. A.; Papakostas, K. T.

    2018-04-01

    A hybrid solar-assisted ground-source heat pump (SAGSHP) system was designed, in the frame of an energy upgrade study, to serve as a heating system in a school building in Greece. The main scope of this study was to examine techniques to reduce the capacity of the heating equipment and to keep the primary energy consumption low. Simulations of the thermal performance of both the building and of five different heating system configurations were performed by using the TRNSYS software. The results are presented in this work and show that the hybrid SAGSHP system displays the lower primary energy consumption among the systems examined. A conventional ground-source heat pump system has the same primary energy consumption, while the heat pump's capacity is double and the ground heat exchanger 2.5 times longer. This work also highlights the contribution of simulation tools to the design of complex heating systems with renewable energy sources.

  3. Rapid deployable global sensing hazard alert system

    Science.gov (United States)

    Cordaro, Joseph V; Tibrea, Steven L; Shull, Davis J; Coleman, Jerry T; Shuler, James M

    2015-04-28

    A rapid deployable global sensing hazard alert system and associated methods of operation are provided. An exemplary system includes a central command, a wireless backhaul network, and a remote monitoring unit. The remote monitoring unit can include a positioning system configured to determine a position of the remote monitoring unit based on one or more signals received from one or more satellites located in Low Earth Orbit. The wireless backhaul network can provide bidirectional communication capability independent of cellular telecommunication networks and the Internet. An exemplary method includes instructing at least one of a plurality of remote monitoring units to provide an alert based at least in part on a location of a hazard and a plurality of positions respectively associated with the plurality of remote monitoring units.

  4. Electronic alerts and clinician turnover: the influence of user acceptance.

    Science.gov (United States)

    Hysong, Sylvia J; Spitzmuller, Christiane; Espadas, Donna; Sittig, Dean F; Singh, Hardeep

    2014-11-01

    Use of certain components of electronic health records (EHRs), such as EHR-based alerting systems (EASs), might reduce provider satisfaction, a strong precursor to turnover. We examined the impact of factors likely to influence providers' acceptance of an alerting system, designed to facilitate electronic communication in outpatient settings, on provider satisfaction, intentions to quit, and turnover. We conducted a cross-sectional Web-based survey of EAS-related practices from a nationwide sample of primary care providers (PCPs) practicing at Department of Veterans Affairs (VA) medical facilities. Of 5001 invited VA PCPs, 2590 completed the survey. We relied on Venkatesh's Unified Theory of Acceptance and Use of Technology to create survey measures of 4 factors likely to impact user acceptance of EAS: supportive norms, monitoring/ feedback, training, and providers' perceptions of the value (PPOV) of EASs to provider effectiveness. Facility-level PCP turnover was measured via the VA's Service Support Center Human Resources Cube. Hypotheses were tested using structural equation modeling. After accounting for intercorrelations among predictors, monitoring/feedback regarding EASs significantly predicted intention to quit (b = 0.30, P < .01), and PPOV of EASs predicted both overall provider satisfaction (b = 0.58, P < .01) and facility-level provider turnover levels (b = -0.19, P < .05), all without relying on any intervening mechanisms. Design, implementation, and use of EASs might impact provider satisfaction and retention. Institutions should consider strategies to help providers perceive greater value in these clinical tools.

  5. From Demonstration System to Prototype: ShakeAlert Beta Users Provide Feedback to Improve Alert Delivery

    Science.gov (United States)

    Strauss, J. A.; Vinci, M.; Steele, W. P.; Allen, R. M.; Hellweg, M.

    2013-12-01

    Earthquake Early Warning (EEW) is a system that can provide a few to tens of seconds to minutes of warning prior to ground shaking at a given location. The goal and purpose of such a system is to reduce the damage, costs, and casualties resulting from an earthquake. A prototype earthquake early warning system (ShakeAlert) is in development by the UC Berkeley Seismological Laboratory, Caltech, ETH Zurich, University of Washington, and the USGS. Events are published to the UserDisplay--ShakeAlert's Java based graphical interface, which is being tested by a small group of beta users throughout California. The beta users receive earthquake alerts in real-time and are providing feedback on their experiences. For early warning alerts to be useful, people, companies, and institutions must know beforehand what actions they will perform when they receive the information. Beta user interactions allow the ShakeAlert team to discern: which alert delivery options are most effective, what changes would make the UserDisplay more useful in a pre-disaster situation, and most importantly, what actions users plan to take for various scenarios. We also collect feedback detailing costs of implementing actions and challenges within the beta user organizations, as well as anticipated benefits and savings. Thus, creating a blueprint for a fully operational system that will meet the needs of the public. New California users as well as the first group of Pacific Northwest users are slated to join the ShakeAlert beta test group in the fall of 2013.

  6. AMDIS Case Conference: Intrusive Medication Safety Alerts.

    Science.gov (United States)

    Graham, J; Levick, D; Schreiber, R

    2010-01-01

    Clinical decision support that provides enhanced patient safety at the point of care frequently encounters significant pushback from clinicians who find the process intrusive or time-consuming. We present a hypothetical medical center's dilemma about its allergy alerting system and discuss similar problems faced by real hospitals. We then share some lessons learned and best practices for institutions who wish to implement these tools themselves.

  7. AMDIS Case Conference: Intrusive Medication Safety Alerts

    OpenAIRE

    Graham, J.; Levick, D.; Schreiber, R.

    2010-01-01

    Clinical decision support that provides enhanced patient safety at the point of care frequently encounters significant pushback from clinicians who find the process intrusive or time-consuming. We present a hypothetical medical center’s dilemma about its allergy alerting system and discuss similar problems faced by real hospitals. We then share some lessons learned and best practices for institutions who wish to implement these tools themselves.

  8. Commercial Mobile Alert Service (CMAS) Scenarios

    Science.gov (United States)

    2012-05-01

    Commercial Mobile Alert Service (CMAS) Scenarios The WEA Project Team May 2012 SPECIAL REPORT CMU/SEI-2012-SR-020 CERT® Division, Software ...Homeland Security under Contract No. FA8721-05-C-0003 with Carnegie Mellon University for the operation of the Software Engineering Institute, a federally...DISTRIBUTES IT “AS IS.” References herein to any specific commercial product, process, or service by trade name, trade mark, manufacturer, or otherwise

  9. Static Analysis Alert Audits: Lexicon and Rules

    Science.gov (United States)

    2016-11-04

    1 Audit Rules and Lexicon Date 00, 2016 © 2016 Carnegie Mellon University [DISTRIBUTION STATEMENT A] This material has been approved for public...DISTRIBUTION STATEMENT A] This material has been approved for public release and unlimited distribution. REV-03.18.2016.0 Static Analysis Alert Audits ...Lexicon And Rules William Snavely 2 Audit Rules and Lexicon Date 00, 2016 © 2016 Carnegie Mellon University [DISTRIBUTION STATEMENT A] This material

  10. Feasibility of seismic alert systems in India

    International Nuclear Information System (INIS)

    Chauhan, P.K.S.; Pandey, Y.

    2012-01-01

    Natural disasters like flood, earthquakes and cyclones are very frequent in India since historical times. As far as the casualties are concerned, globally earthquakes are second in the list after the flood. The loss of property due to these earthquakes is huge and enormous. In the light of the present knowledge base, earthquake prediction is far from being a reality. An early earthquake warning has potential to save the precious human lives. In the present day scenario seismic instrumentation and telecommunication permits the implementation of seismic alert system (SAS) based on the real-time measurement of ground motions near the source. SAS is capable of providing a warning of several seconds before the arrival of destructive seismic waves caused by a large earthquake. SAS is successfully operational in many countries of the world. In a country, like India where earthquakes are taking heavy toll on the human lives and property, seismic alert system may prove to be very important step in natural hazard mitigation strategy. In this paper, an attempt has been made to compute the available alarm time before the destructive earthquake waves reaches to the cities like Delhi, Lucknow, Patna and Kolkata taking Himalaya as the source and feasibility of seismic alert system in Indian scenario. (author)

  11. An IDS Alerts Aggregation Algorithm Based on Rough Set Theory

    Science.gov (United States)

    Zhang, Ru; Guo, Tao; Liu, Jianyi

    2018-03-01

    Within a system in which has been deployed several IDS, a great number of alerts can be triggered by a single security event, making real alerts harder to be found. To deal with redundant alerts, we propose a scheme based on rough set theory. In combination with basic concepts in rough set theory, the importance of attributes in alerts was calculated firstly. With the result of attributes importance, we could compute the similarity of two alerts, which will be compared with a pre-defined threshold to determine whether these two alerts can be aggregated or not. Also, time interval should be taken into consideration. Allowed time interval for different types of alerts is computed individually, since different types of alerts may have different time gap between two alerts. In the end of this paper, we apply proposed scheme on DAPRA98 dataset and the results of experiment show that our scheme can efficiently reduce the redundancy of alerts so that administrators of security system could avoid wasting time on useless alerts.

  12. Impact of electronic-alerting of acute kidney injury: workgroup statements from the 15(th) ADQI Consensus Conference.

    Science.gov (United States)

    Hoste, Eric A J; Kashani, Kianoush; Gibney, Noel; Wilson, F Perry; Ronco, Claudio; Goldstein, Stuart L; Kellum, John A; Bagshaw, Sean M

    2016-01-01

    Among hospitalized patients, acute kidney injury is common and associated with significant morbidity and risk for mortality. The use of electronic health records (EHR) for prediction and detection of this important clinical syndrome has grown in the past decade. The steering committee of the 15(th) Acute Dialysis Quality Initiative (ADQI) conference dedicated a workgroup with the task of identifying elements that may impact the course of events following Acute Kidney Injury (AKI) e-alert. Following an extensive, non-systematic literature search, we used a modified Delphi process to reach consensus regarding several aspects of the utilization of AKI e-alerts. Topics discussed in this workgroup included progress in evidence base practices, the characteristics of an optimal e-alert, the measures of efficacy and effectiveness, and finally what responses would be considered best practices following AKI e-alerts. Authors concluded that the current evidence for e-alert system efficacy, although growing, remains insufficient. Technology and human-related factors were found to be crucial elements of any future investigation or implementation of such tools. The group also concluded that implementation of such systems should not be done without a vigorous plan to evaluate the efficacy and effectiveness of e-alerts. Efficacy and effectiveness of e-alerts should be measured by context-specific process and patient outcomes. Finally, the group made several suggestions regarding the clinical decision support that should be considered following successful e-alert implementation. This paper reflects the findings of a non-systematic review and expert opinion. We recommend implementation of the findings of this workgroup report for use of AKI e-alerts.

  13. Alerts Visualization and Clustering in Network-based Intrusion Detection

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Dr. Li [University of Tennessee; Gasior, Wade C [ORNL; Dasireddy, Swetha [University of Tennessee

    2010-04-01

    Today's Intrusion detection systems when deployed on a busy network overload the network with huge number of alerts. This behavior of producing too much raw information makes it less effective. We propose a system which takes both raw data and Snort alerts to visualize and analyze possible intrusions in a network. Then we present with two models for the visualization of clustered alerts. Our first model gives the network administrator with the logical topology of the network and detailed information of each node that involves its associated alerts and connections. In the second model, flocking model, presents the network administrator with the visual representation of IDS data in which each alert is represented in different color and the alerts with maximum similarity move together. This gives network administrator with the idea of detecting various of intrusions through visualizing the alert patterns.

  14. Assuring human operator alertness at night in power plants

    International Nuclear Information System (INIS)

    Moore-Ede, M.C.

    1988-01-01

    The human body is not designed for peak alertness and performance at night, nor is it well-equipped to cope with the frequent day-night inversions required by rotating shift work schedules. As a result, the human operator can become the weak link in a complex technological operation such as a nuclear power plant. The high degree of dependence on human operator vigilance, decision-making ability and performance that is required in nuclear power plant operations can conflict with the human sleepiness and error-proneness which naturally occur during the night shift or after extended periods without adequate sleep. An opportunity to address these problems has come from a series of major research advances in basic circadian physiology

  15. Impact of real-time electronic alerting of acute kidney injury on therapeutic intervention and progression of RIFLE class.

    Science.gov (United States)

    Colpaert, Kirsten; Hoste, Eric A; Steurbaut, Kristof; Benoit, Dominique; Van Hoecke, Sofie; De Turck, Filip; Decruyenaere, Johan

    2012-04-01

    To evaluate whether a real-time electronic alert system or "AKI sniffer," which is based on the RIFLE classification criteria (Risk, Injury and Failure), would have an impact on therapeutic interventions and acute kidney injury progression. Prospective intervention study. Surgical and medical intensive care unit in a tertiary care hospital. A total of 951 patients having in total 1,079 admission episodes were admitted during the study period (prealert control group: 227, alert group: 616, and postalert control group: 236). Three study phases were compared: A 1.5-month prealert control phase in which physicians were blinded for the acute kidney injury sniffer and a 3-month intervention phase with real-time alerting of worsening RIFLE class through the Digital Enhanced Cordless Technology telephone system followed by a second 1.5-month postalert control phase. A total of 2593 acute kidney injury alerts were recorded with a balanced distribution over all study phases. Most acute kidney injury alerts were RIFLE class risk (59.8%) followed by RIFLE class injury (34.1%) and failure (6.1%). A higher percentage of patients in the alert group received therapeutic intervention within 60 mins after the acute kidney injury alert (28.7% in alert group vs. 7.9% and 10.4% in the pre- and postalert control groups, respectively, p μ .001). In the alert group, more patients received fluid therapy (23.0% vs. 4.9% and 9.2%, p μ .01), diuretics (4.2% vs. 2.6% and 0.8%, p μ .001), or vasopressors (3.9% vs. 1.1% and 0.8%, p μ .001). Furthermore, these patients had a shorter time to intervention (p μ .001). A higher proportion of patients in the alert group showed return to a baseline kidney function within 8 hrs after an acute kidney injury alert "from normal to risk" compared with patients in the control group (p = .048). The real-time alerting of every worsening RIFLE class by the acute kidney injury sniffer increased the number and timeliness of early therapeutic interventions

  16. A mobile care system with alert mechanism.

    Science.gov (United States)

    Lee, Ren-Guey; Chen, Kuei-Chien; Hsiao, Chun-Chieh; Tseng, Chwan-Lu

    2007-09-01

    Hypertension and arrhythmia are chronic diseases, which can be effectively prevented and controlled only if the physiological parameters of the patient are constantly monitored, along with the full support of the health education and professional medical care. In this paper, a role-based intelligent mobile care system with alert mechanism in chronic care environment is proposed and implemented. The roles in our system include patients, physicians, nurses, and healthcare providers. Each of the roles represents a person that uses a mobile device such as a mobile phone to communicate with the server setup in the care center such that he or she can go around without restrictions. For commercial mobile phones with Bluetooth communication capability attached to chronic patients, we have developed physiological signal recognition algorithms that were implemented and built-in in the mobile phone without affecting its original communication functions. It is thus possible to integrate several front-end mobile care devices with Bluetooth communication capability to extract patients' various physiological parameters [such as blood pressure, pulse, saturation of haemoglobin (SpO2), and electrocardiogram (ECG)], to monitor multiple physiological signals without space limit, and to upload important or abnormal physiological information to healthcare center for storage and analysis or transmit the information to physicians and healthcare providers for further processing. Thus, the physiological signal extraction devices only have to deal with signal extraction and wireless transmission. Since they do not have to do signal processing, their form factor can be further reduced to reach the goal of microminiaturization and power saving. An alert management mechanism has been included in back-end healthcare center to initiate various strategies for automatic emergency alerts after receiving emergency messages or after automatically recognizing emergency messages. Within the time

  17. ToxAlerts: a Web server of structural alerts for toxic chemicals and compounds with potential adverse reactions.

    Science.gov (United States)

    Sushko, Iurii; Salmina, Elena; Potemkin, Vladimir A; Poda, Gennadiy; Tetko, Igor V

    2012-08-27

    The article presents a Web-based platform for collecting and storing toxicological structural alerts from literature and for virtual screening of chemical libraries to flag potentially toxic chemicals and compounds that can cause adverse side effects. An alert is uniquely identified by a SMARTS template, a toxicological endpoint, and a publication where the alert was described. Additionally, the system allows storing complementary information such as name, comments, and mechanism of action, as well as other data. Most importantly, the platform can be easily used for fast virtual screening of large chemical datasets, focused libraries, or newly designed compounds against the toxicological alerts, providing a detailed profile of the chemicals grouped by structural alerts and endpoints. Such a facility can be used for decision making regarding whether a compound should be tested experimentally, validated with available QSAR models, or eliminated from consideration altogether. The alert-based screening can also be helpful for an easier interpretation of more complex QSAR models. The system is publicly accessible and tightly integrated with the Online Chemical Modeling Environment (OCHEM, http://ochem.eu). The system is open and expandable: any registered OCHEM user can introduce new alerts, browse, edit alerts introduced by other users, and virtually screen his/her data sets against all or selected alerts. The user sets being passed through the structural alerts can be used at OCHEM for other typical tasks: exporting in a wide variety of formats, development of QSAR models, additional filtering by other criteria, etc. The database already contains almost 600 structural alerts for such endpoints as mutagenicity, carcinogenicity, skin sensitization, compounds that undergo metabolic activation, and compounds that form reactive metabolites and, thus, can cause adverse reactions. The ToxAlerts platform is accessible on the Web at http://ochem.eu/alerts, and it is constantly

  18. Disease spreading with epidemic alert on small-world networks

    International Nuclear Information System (INIS)

    Han, Xiao-Pu

    2007-01-01

    Base on two-dimension small-world networks, a susceptible-infected model with epidemic alert is proposed in this Letter. In this model, if some parts of the network are alarmed as dangerous, a fraction of edges between the alarmed parts and others will be removed, and two cases of alerting rules that the degree and frequency of contacts kept unchanged are considered respectively. The numerical simulations show that the spreading velocity is reduced by the accurate and timely epidemic alert, and the more accurate and timely, the stronger the deceleration effect. This model indicates that to broadcast epidemic alert timely is helpful and necessary in the control of epidemic spreading, and in agreement with the general view of epidemic alert. This work is helpful to understand the effects of epidemic alert on disease spreading

  19. Electronic Immunization Alerts and Spillover Effects on Other Preventive Care.

    Science.gov (United States)

    Kim, Julia M; Rivera, Maria; Persing, Nichole; Bundy, David G; Psoter, Kevin J; Ghazarian, Sharon R; Miller, Marlene R; Solomon, Barry S

    2017-08-01

    The impact of electronic health record (EHR) immunization clinical alert systems on the delivery of other preventive services remains unknown. We assessed for spillover effects of an EHR immunization alert on delivery of 6 other preventive services, in children 18 to 30 months of age needing immunizations. We conducted a secondary data analysis, with additional primary data collection, of a randomized, historically controlled trial to improve immunization rates with EHR alerts, in an urban, primary care clinic. No significant differences were found in screening for anemia, lead, development, nutrition, and injury prevention counseling in children prompting EHR immunization alerts (n = 129), compared with controls (n = 135). Significant increases in oral health screening in patients prompting EHR alerts (odds ratio = 4.8, 95% CI = 1.8-13.0) were likely due to practice changes over time. An EHR clinical alert system targeting immunizations did not have a spillover effect on the delivery of other preventive services.

  20. Sleepiness and alertness in American industries

    International Nuclear Information System (INIS)

    Coleman, R.M.; Dillingham, J.; Dement, W.C.

    1989-01-01

    Recent evidence that industrial accidents may be caused in part by shiftworkers' lack of alertness has caused growing concern at the US Nuclear Regulatory Commission and within the scientific community. The purpose of the study reported in this paper was threefold: (1) Is sleepiness on the job specific to utility plants? (2) Are performance and safety problems caused by sleepiness specific to utility plants? (3) Are specific shift schedules associated with a higher prevalence of sleepiness? Findings indicate sleepiness on the job among shiftworkers is a widespread problem, not limited to the nuclear power industry. The most common solution in American industry is to overstaff each shift and discipline sleeping employees. Results show this is not effective. A more proactive solution is recommended including some of the following: (1) Provide employees education to assist adjustment to shiftwork. (2) Design and implement shift schedules that are more compatible with human physiological capabilities. (3) Allow officially sanctioned napping on shift as is done in Japan. (4) Divide 6-, 8-, or 12-h shifts into smaller blocks of 2 to 3 h of primary duty. (5) make the environment where employees work more conductive to alertness. (6) Develop a firehouse type of schedule where some employees sleep throughout the night, but are awakened if operational problems arise. (7) Provide incentives to employees to adjust their life style to the night shift and reward them with time off

  1. Sleepiness and alertness in American industries

    Energy Technology Data Exchange (ETDEWEB)

    Coleman, R.M.; Dillingham, J.; Dement, W.C.

    1989-01-01

    Recent evidence that industrial accidents may be caused in part by shiftworkers' lack of alertness has caused growing concern at the US Nuclear Regulatory Commission and within the scientific community. The purpose of the study reported in this paper was threefold: (1) Is sleepiness on the job specific to utility plants (2) Are performance and safety problems caused by sleepiness specific to utility plants (3) Are specific shift schedules associated with a higher prevalence of sleepiness Findings indicate sleepiness on the job among shiftworkers is a widespread problem, not limited to the nuclear power industry. The most common solution in American industry is to overstaff each shift and discipline sleeping employees. Results show this is not effective. A more proactive solution is recommended including some of the following: (1) Provide employees education to assist adjustment to shiftwork. (2) Design and implement shift schedules that are more compatible with human physiological capabilities. (3) Allow officially sanctioned napping on shift as is done in Japan. (4) Divide 6-, 8-, or 12-h shifts into smaller blocks of 2 to 3 h of primary duty. (5) make the environment where employees work more conductive to alertness. (6) Develop a firehouse type of schedule where some employees sleep throughout the night, but are awakened if operational problems arise. (7) Provide incentives to employees to adjust their life style to the night shift and reward them with time off.

  2. A Service-Oriented Healthcare Message Alerting Architecture in an Asia Medical Center: A Case Study

    Directory of Open Access Journals (Sweden)

    Jin-Shin Lai

    2009-06-01

    Full Text Available This paper illustrates how our development team has used some information technologies to let physicians obtain an instant abnormal laboratory result report for critical patient care services. We have implementeda healthcare message alerting system (HMAS on a healthcare short message service (HSMS engine and the distributed healthcare-oriented service environment (DiHOSE in the National Taiwan University Hospital (NTUH. The HSMS engine has a general interface for all applications which could easily send any kind of alerting messages. Fundamentally, the DiHOSE uses HL7 standard formats to process the information exchange behaviors and can be flexibly extended for reasonable user requirements. The disease surveillance subsystem is an integral part of NTUH new hospital information system which is based on DiHOSE and the disease surveillance subsystem would send alerting messages through the HSMS engine. The latest cell phone message alerting subsystem, a case study, in NTUH proved that the DiHOSE could integrate the user required functions without much work. We concluded that both HSMS and DiHOSE can generalize and extend application demands efficiently.

  3. CERN alerter-RSS based system for information broadcast to all CERN offices

    International Nuclear Information System (INIS)

    Otto, R

    2008-01-01

    Nearly every large organization uses a tool to broadcast messages and information across the internal campus (messages like alerts announcing interruption in services or just information about upcoming events). These tools typically allow administrators (operators) to send 'targeted' messages which are sent only to specific groups of users or computers, e/g only those located in a specified building or connected to a particular computing service. CERN has a long history of such tools: CERNVMS's SPM q uotMESSAGE command, Zephyr [2] and the most recent the NICE Alerter based on the NNTP protocol. The NICE Alerter used on all Windows-based computers had to be phased out as a consequence of phasing out NNTP at CERN. The new solution to broadcast information messages on the CERN campus continues to provide the service based on cross-platform technologies, hence minimizing custom developments and relying on commercial software as much as possible. The new system, called CERN Alerter, is based on RSS (Really Simple Syndication) [9] for the transport protocol and uses Microsoft SharePoint as the backend for database and posting interface. The windows-based client relies on Internet Explorer 7.0 with custom code to trigger the window pop-ups and the notifications for new events. Linux and Mac OS X clients could also rely on any RSS readers to subscribe to targeted notifications. The paper covers the architecture and implementation aspects of the new system

  4. Simulation and optimisation of a ground source heat pump with different ground heat exchanger configurations for a single-family residential house

    DEFF Research Database (Denmark)

    Pavlov, Georgi Krasimiroy; Olesen, Bjarne W.

    2012-01-01

    In the future there will be an increased demand for energy efficient cooling of residential buildings. Therefore it is essential to develop cooling concepts that are passive and/or using very little primary energy. A possible solution is a ground source heat pump combined with a low-temperature h....... For the studied geographical location, passive cooling by bypassing the heat pump and using only the ground heat exchanger can provide acceptable room temperatures.......In the future there will be an increased demand for energy efficient cooling of residential buildings. Therefore it is essential to develop cooling concepts that are passive and/or using very little primary energy. A possible solution is a ground source heat pump combined with a low......-temperature heating and high-temperature cooling system. The present work evaluates the performance in relation to thermal comfort and energy consumption of a GSHP with different GHE concepts. The different configurations are analyzed being part of the energy supply system of a low-energy residential house...

  5. Swift Burst Alert Telescope (BAT) Instrument Response

    International Nuclear Information System (INIS)

    Parsons, A.; Barthelmy, S.; Cummings, J.; Gehrels, N.; Hullinger, D.; Krimm, H.; Markwardt, C.; Tueller, J.; Fenimore, E.; Palmer, D.; Sato, G.; Takahashi, T.; Nakazawa, K.; Okada, Y.; Takahashi, H.; Suzuki, M.; Tashiro, M.

    2004-01-01

    The Burst Alert Telescope (BAT), a large coded aperture instrument with a wide field-of-view (FOV), provides the gamma-ray burst triggers and locations for the Swift Gamma-Ray Burst Explorer. In addition to providing this imaging information, BAT will perform a 15 keV - 150 keV all-sky hard x-ray survey based on the serendipitous pointings resulting from the study of gamma-ray bursts, and will also monitor the sky for transient hard x-ray sources. For BAT to provide spectral and photometric information for the gamma-ray bursts, the transient sources and the all-sky survey, the BAT instrument response must be determined to an increasingly greater accuracy. This paper describes the spectral models and the ground calibration experiments used to determine the BAT response to an accuracy suitable for gamma-ray burst studies

  6. Stability of alert survivable forces during reductions

    Energy Technology Data Exchange (ETDEWEB)

    Canavan, G.H.

    1998-01-01

    The stability of current and projected strategic forces are discussed within a framework that contains elements of current US and Russian analyses. For current force levels and high alert, stability levels are high, as are the levels of potential strikes, due to the large forces deployed. As force levels drop towards those of current value target sets, the analysis becomes linear, concern shifts from stability to reconstitution, and survivable forces drop out. Adverse marginal costs generally provide disincentives for the reduction of vulnerable weapons, but the exchange of vulnerable for survivable weapons could reduce cost while increasing stability even for aggressive participants. Exchanges between effective vulnerable and survivable missile forces are studied with an aggregated, probabilistic model, which optimizes each sides` first and determines each sides` second strikes and costs by minimizing first strike costs.

  7. 77 FR 33661 - Review of the Emergency Alert System

    Science.gov (United States)

    2012-06-07

    ... Commission's Review of the Emergency Alert System, Fifth Report and Order (Order). This document is... FEDERAL COMMUNICATIONS COMMISSION 47 CFR Part 11 [EB Docket No. 04-296; FCC 12-7] Review of the Emergency Alert System AGENCY: Federal Communications Commission. ACTION: Final rule; announcement of...

  8. Development of an integrated campus security alerting system ...

    African Journals Online (AJOL)

    This work presents an integrated alerting system which uses both the Internet Protocol (IP) cameras and micro-switches for monitoring security situations thereby providing an immediate alerting signal to the security personnel. The system has the input unit, processing unit, control unit and the power supply unit as its ...

  9. A new method for determining a sector alert

    Science.gov (United States)

    2008-09-29

    The Traffic Flow Management System (TFMS) currently declares an alert for any 15-minute interval in which the predicted demand exceeds the Monitor/Alert Parameter (MAP) for any airport, sector, or fix. For a sector, TFMS predicts the demand for each ...

  10. The effect of automated alerts on provider ordering behavior in an outpatient setting.

    Directory of Open Access Journals (Sweden)

    2005-09-01

    Full Text Available BACKGROUND: Computerized order entry systems have the potential to prevent medication errors and decrease adverse drug events with the use of clinical-decision support systems presenting alerts to providers. Despite the large volume of medications prescribed in the outpatient setting, few studies have assessed the impact of automated alerts on medication errors related to drug-laboratory interactions in an outpatient primary-care setting. METHODS AND FINDINGS: A primary-care clinic in an integrated safety net institution was the setting for the study. In collaboration with commercial information technology vendors, rules were developed to address a set of drug-laboratory interactions. All patients seen in the clinic during the study period were eligible for the intervention. As providers ordered medications on a computer, an alert was displayed if a relevant drug-laboratory interaction existed. Comparisons were made between baseline and postintervention time periods. Provider ordering behavior was monitored focusing on the number of medication orders not completed and the number of rule-associated laboratory test orders initiated after alert display. Adverse drug events were assessed by doing a random sample of chart reviews using the Naranjo scoring scale. The rule processed 16,291 times during the study period on all possible medication orders: 7,017 during the pre-intervention period and 9,274 during the postintervention period. During the postintervention period, an alert was displayed for 11.8% (1,093 out of 9,274 of the times the rule processed, with 5.6% for only "missing laboratory values," 6.0% for only "abnormal laboratory values," and 0.2% for both types of alerts. Focusing on 18 high-volume and high-risk medications revealed a significant increase in the percentage of time the provider stopped the ordering process and did not complete the medication order when an alert for an abnormal rule-associated laboratory result was displayed

  11. Validation of the CME Geomagnetic forecast alerts under COMESEP alert system

    Science.gov (United States)

    Dumbovic, Mateja; Srivastava, Nandita; Khodia, Yamini; Vršnak, Bojan; Devos, Andy; Rodriguez, Luciano

    2017-04-01

    An automated space weather alert system has been developed under the EU FP7 project COMESEP (COronal Mass Ejections and Solar Energetic Particles: http://comesep.aeronomy.be) to forecast solar energetic particles (SEP) and coronal mass ejection (CME) risk levels at Earth. COMESEP alert system uses automated detection tool CACTus to detect potentially threatening CMEs, drag-based model (DBM) to predict their arrival and CME geo-effectiveness tool (CGFT) to predict their geomagnetic impact. Whenever CACTus detects a halo or partial halo CME and issues an alert, DBM calculates its arrival time at Earth and CGFT calculates its geomagnetic risk level. Geomagnetic risk level is calculated based on an estimation of the CME arrival probability and its likely geo-effectiveness, as well as an estimate of the geomagnetic-storm duration. We present the evaluation of the CME risk level forecast with COMESEP alert system based on a study of geo-effective CMEs observed during 2014. The validation of the forecast tool is done by comparing the forecasts with observations. In addition, we test the success rate of the automatic forecasts (without human intervention) against the forecasts with human intervention using advanced versions of DBM and CGFT (self standing tools available at Hvar Observatory website: http://oh.geof.unizg.hr). The results implicate that the success rate of the forecast is higher with human intervention and using more advanced tools. This work has received funding from the European Commission FP7 Project COMESEP (263252). We acknowledge the support of Croatian Science Foundation under the project 6212 „Solar and Stellar Variability".

  12. Alert Messaging in the CMS Distributed Workflow System

    International Nuclear Information System (INIS)

    Maxa, Zdenek

    2012-01-01

    WMAgent is the core component of the CMS workload management system. One of the features of this job managing platform is a configurable messaging system aimed at generating, distributing and processing alerts: short messages describing a given alert-worthy information or pathological condition. Apart from the framework's sub-components running within the WMAgent instances, there is a stand-alone application collecting alerts from all WMAgent instances running across the CMS distributed computing environment. The alert framework has a versatile design that allows for receiving alert messages also from other CMS production applications, such as PhEDEx data transfer manager. We present implementation details of the system, including its Python implementation using ZeroMQ, CouchDB message storage and future visions as well as operational experiences. Inter-operation with monitoring platforms such as Dashboard or Lemon is described.

  13. In situ study of the effect of ground source heat pump on shallow ground-water quality in the late Pleistocene terrace area of Tokyo, Japan

    Science.gov (United States)

    Takemura, T.; Uemura, K.; Akiba, Y.; Ota, M.

    2015-12-01

    The implementation of ground source heat pump (GSHP) systems has rapidly increased around the world, since they reduce carbon dioxide emissions and save electric energy. The GSHP system transfer heat into the geosphere zone when air conditioners are used to cool rooms or buildings. However, the effects of temperature increase on the quality of underground water has yet to be fully investigated. In order to reduce the risks of ground-water pollution by the installed GSHPs, it is important to evaluate the effect of temperature change on the ground-water quality. In this study, we installed a closed loop GSHP system on a heat exchange well along with a monitoring well drilled to measure ground-water quality and temperature. The monitoring well was drilled at 0.1cm away from the heat exchange well. We observed that changes of temperature in the heat exchange well affected the water quality, especially turbidity, in gravelly layer.

  14. A quasi-transient model of a transcritical carbon dioxide direct-expansion ground source heat pump for space and water heating

    International Nuclear Information System (INIS)

    Eslami-Nejad, Parham; Ouzzane, Mohamed; Aidoun, Zine

    2015-01-01

    In this study, a theoretical quasi-transient model is developed for detailed simulations of a carbon dioxide (CO_2) direct-expansion ground source heat pump (DX-GSHP). This model combines a transient analytical model for the ground, steady-state numerical models for the borehole and the gas cooler, as well as several thermodynamic models for the remaining components of a conventional heat pump, organized in interacting subroutines to form a powerful simulation tool. Extensive validation combining experimental data and CFD-generated results was performed for the borehole before the tool was used to simulate a practical application case. Performance is investigated for a system satisfying both space heating and domestic hot water requirements of a typical single family detached home in a cold climate region. The variation of different system parameters is also evaluated in this study. It is shown that CO_2 DX-GSHPs can offer relatively efficient and stable performance for integrated water and space heating applications. Furthermore, the importance of an accurate geothermal borehole sizing is highlighted for the DX-CO_2 heat pump systems. It is shown that, due to changes in the system working conditions, the total borehole length is not linearly correlated with the heat pump energy consumption and other parameters such as heat pump coefficient of performance and pressure drop in ground heat exchangers. Results showed that increasing the total borehole length of an optimum design (reference case study) by 25% decreases the total annual energy consumption by only 6%. However, reducing total borehole length of the reference case by 25% increases the total annual energy consumption by 10%. - Highlights: • A quasi-transient model for CO_2 direct-exchange ground-source heat pump is developed. • Validation combining experimental data and CFD-generated results was performed. • The effect of the borehole size on the design parameters is evaluated. • Results show that

  15. A simulation-based analysis of variable flow pumping in ground source heat pump systems with different types of borehole heat exchangers: A case study

    International Nuclear Information System (INIS)

    Zarrella, Angelo; Emmi, Giuseppe; De Carli, Michele

    2017-01-01

    Highlights: • The work focuses on the variable flow in ground source heat pump systems. • The constant and variable speed circulation pumps in the ground loop are compared. • The constant temperature difference control across the heat pump is studied. • The variable flow affects the energy performance of the heat pump. • The constant temperature difference control offers an attractive energy saving. - Abstract: A simulation model of ground source heat pump systems has been used to investigate to what extent a variable flow of the heat-carrier fluid of the ground loop affects the energy efficiency of the entire system. The model contemporaneously considers the borehole heat exchangers, the heat pump, the building load, and the control strategies for the circulation pumps of the ground loop. A constant speed of the circulation pumps of the ground loop was compared with a variable flow controlled by means of a constant temperature difference across the heat pump on the ground side considering the load profile of an office building located in North Italy. The analysis was carried out for a single U-tube, double U-tube and coaxial pipe heat exchangers. The control strategies adopted to manage the flow rate of the heat-carrier fluid of the ground loop affect both the heat exchange rate of the borehole field and the heat pump’s long-term energy efficiency. The simulations show considerable differences in the system’s seasonal energy efficiency. The constant speed of the circulation pumps leads to the best results as far as the heat pump’s energy performance was concerned, but this advantage was lost because of the greater amount of electrical energy used by the circulation pumps; this, of course, affects the energy efficiency of the entire system. The optimal solution appears then to be a constant temperature difference in the heat-carrier fluid across the heat pump.

  16. Fatigue in Younger and Older Drivers: Effectiveness of an Alertness-Maintaining Task.

    Science.gov (United States)

    Song, Woojin; Woon, Fu L; Doong, Alice; Persad, Carol; Tijerina, Louis; Pandit, Pooja; Cline, Carol; Giordani, Bruno

    2017-09-01

    The aim of this study was to examine the effects of an alertness-maintaining task (AMT) in older, fatigued drivers. Fatigue during driving increases crash risk, and previous research suggests that alertness and driving in younger adults may be improved using a secondary AMT during boring, fatigue-eliciting drives. However, the potential impact of an AMT on driving has not been investigated in older drivers whose ability to complete dual tasks has been shown to decline and therefore may be negatively affected with an AMT in driving. Younger ( n = 29) and older drivers ( n = 39) participated in a 50-minute simulated drive designed to induce fatigue, followed by four 10-minute sessions alternating between driving with and without an AMT. Younger drivers were significantly more affected by fatigue on driving performance than were older drivers but benefitted significantly from the AMT. Older drivers did not demonstrate increased driver errors with fatigue, and driving did not deteriorate significantly during participation in the AMT condition, although their speed was significantly more variable with the AMT. Consistent with earlier research, an AMT applied during fatiguing driving is effective in improving alertness and reducing driving errors in younger drivers. Importantly, older drivers were relatively unaffected by fatigue, and use of an AMT did not detrimentally affect their driving performance. These results support the potential use of an AMT as a new automotive technology to improve fatigue and promote driver safety, though the benefits of such technology may differ between different age groups.

  17. Gaia Science Alerts: Early Validation Phase Data from Gaia

    Science.gov (United States)

    Walton, Nicholas; Hodgkin, Simon; van Leeuwen, Floor

    2015-08-01

    The ESA Gaia satellite launched Dec 2013, and after successful completion of its in orbit commissioning in July 2014, begun routine operations, with the aim to accurately measure the astrometric and astrophysical properties of more than a billion stars in our Milky Way.As a significant by product of its observational scanning law, where each point on the sky is observed multiple times (~80 revisits on average) over the nominal 5 year mission, Gaia has significant utility in detecting new transients, both flux (e.g. Supernovae, Flare stars) and positional (e.g. Asteroids).We will present the current status of the Gaia Photometric Science Alerts (PSA) system that has been developed within the Gaia DPAC. The PSA pipeline provides a quick look analysis of the daily data stream from Gaia, and identifies new photometric alerts, from analysis of the object photometric and the low resolution spectro-photometric data. Via a set of filters, those identified as astrophysical in nature, are published to the community. The information provided currently includes positional and flux information.The Gaia Alerts working group has organised a significant early stage followup campaign, providing access to a wide variety of followup facilities. These have been used to provide classification spectra of the Gaia alert candidates, with the early phase data confirming that the alerts issued are indeed largely astrophysical transients, with only a small contamination rate.The presentation will address the early phase issues that have been addressed in localising and classifying alerts in the early phase of Gaia observations (for instance, how lack of early knowledge of the sky as seen by Gaia was mitigated by reference to external image data), and how the alert rate published by the PSA will ramp up towards the end of 2015, with the availability of more Gaia sky data.Information concerning the Gaia alerts system can be found at http://gaia.ac.uk/selected-gaia-science-alerts

  18. Perceptual evaluation of visual alerts in surveillance videos

    Science.gov (United States)

    Rogowitz, Bernice E.; Topkara, Mercan; Pfeiffer, William; Hampapur, Arun

    2015-03-01

    Visual alerts are commonly used in video monitoring and surveillance systems to mark events, presumably making them more salient to human observers. Surprisingly, the effectiveness of computer-generated alerts in improving human performance has not been widely studied. To address this gap, we have developed a tool for simulating different alert parameters in a realistic visual monitoring situation, and have measured human detection performance under conditions that emulated different set-points in a surveillance algorithm. In the High-Sensitivity condition, the simulated alerts identified 100% of the events with many false alarms. In the Lower-Sensitivity condition, the simulated alerts correctly identified 70% of the targets, with fewer false alarms. In the control condition, no simulated alerts were provided. To explore the effects of learning, subjects performed these tasks in three sessions, on separate days, in a counterbalanced, within subject design. We explore these results within the context of cognitive models of human attention and learning. We found that human observers were more likely to respond to events when marked by a visual alert. Learning played a major role in the two alert conditions. In the first session, observers generated almost twice as many False Alarms as in the No-Alert condition, as the observers responded pre-attentively to the computer-generated false alarms. However, this rate dropped equally dramatically in later sessions, as observers learned to discount the false cues. Highest observer Precision, Hits/(Hits + False Alarms), was achieved in the High Sensitivity condition, but only after training. The successful evaluation of surveillance systems depends on understanding human attention and performance.

  19. Self-indicating radiation alert dosemeter (SIRAD)

    International Nuclear Information System (INIS)

    Riel, G. K.; Winters, P.; Patel, G.; Patel, P.

    2006-01-01

    In an event of a nuclear or dirty bomb explosion and a radiological accident, there is a need for self-indicating instant radiation dosemeter for monitoring radiation exposure. The self-indicating instant radiation alert dosemeter (SIRAD) is a credit card size radiation dosemeter for monitoring ionising radiation from a few hundredths of a Gray to a few Gray. It is always active and is ready to use. It needs no battery. The dosemeter develops colour instantly upon exposure, and the colour intensifies with dose. It has a colour chart so that the dose on the active element may be read by matching its colour with the chart that is printed next to it on the card. However, in this work, the dose is measured by the optical density of the element. The dosemeter cannot be reset. The response changes by 3 y at room temperature. It contains no hazardous materials. The dosemeter would meet the requirements of instantly monitoring high dose in an event of a nuclear or dirty bomb explosion or a radiation accident. (authors)

  20. Self-indicating radiation alert dosemeter (SIRAD).

    Science.gov (United States)

    Riel, Gordon K; Winters, Patrick; Patel, Gordhan; Patel, Paresh

    2006-01-01

    In an event of a nuclear or dirty bomb explosion and a radiological accident, there is a need for self-indicating instant radiation dosemeter for monitoring radiation exposure. The self-indicating instant radiation alert dosemeter (SIRAD) is a credit card size radiation dosemeter for monitoring ionising radiation from a few hundredths of a Gray to a few Gray. It is always active and is ready to use. It needs no battery. The dosemeter develops colour instantly upon exposure, and the colour intensifies with dose. It has a colour chart so that the dose on the active element may be read by matching its colour with the chart that is printed next to it on the card. However, in this work, the dose is measured by the optical density of the element. The dosemeter cannot be reset. The response changes by 3 y at room temperature. It contains no hazardous materials. The dosemeter would meet the requirements of instantly monitoring high dose in an event of a nuclear or dirty bomb explosion or a radiation accident.

  1. Real-time alerts and reminders using information systems.

    Science.gov (United States)

    Wanderer, Jonathan P; Sandberg, Warren S; Ehrenfeld, Jesse M

    2011-09-01

    Adoption of information systems throughout the hospital environment has enabled the development of real-time physiologic alerts and clinician reminder systems. These clinical tools can be made available through the deployment of anesthesia information management systems (AIMS). Creating usable alert systems requires understanding of technical considerations. Various successful implementations are reviewed, encompassing cost reduction, improved revenue capture, timely antibiotic administration, and postoperative nausea and vomiting prophylaxis. Challenges to the widespread use of real-time alerts and reminders include AIMS adoption rates and the difficulty in choosing appropriate areas and approaches for information systems support. Copyright © 2011 Elsevier Inc. All rights reserved.

  2. Contributors to Frequent Telehealth Alerts Including False Alerts for Patients with Heart Failure: A Mixed Methods Exploration

    Science.gov (United States)

    Radhakrishna, K.; Bowles, K.; Zettek-Sumner, A.

    2013-01-01

    Summary Background Telehealth data overload through high alert generation is a significant barrier to sustained adoption of telehealth for managing HF patients. Objective To explore the factors contributing to frequent telehealth alerts including false alerts for Medicare heart failure (HF) patients admitted to a home health agency. Materials and Methods A mixed methods design that combined quantitative correlation analysis of patient characteristic data with number of telehealth alerts and qualitative analysis of telehealth and visiting nurses’ notes on follow-up actions to patients’ telehealth alerts was employed. All the quantitative and qualitative data was collected through retrospective review of electronic records of the home heath agency. Results Subjects in the study had a mean age of 83 (SD = 7.6); 56% were female. Patient co-morbidities (ppatient characteristics along with establishing patient-centered telehealth outcome goals may allow meaningful generation of telehealth alerts. Reducing avoidable telehealth alerts could vastly improve the efficiency and sustainability of telehealth programs for HF management. PMID:24454576

  3. Alternative Opportunistic Alert Diffusion to Support Infrastructure Failure during Disasters

    Directory of Open Access Journals (Sweden)

    Farouk Mezghani

    2017-10-01

    Full Text Available Opportunistic communications present a promising solution for disaster network recovery in emergency situations such as hurricanes, earthquakes, and floods, where infrastructure might be destroyed. Some recent works in the literature have proposed opportunistic-based disaster recovery solutions, but they have omitted the consideration of mobile devices that come with different network technologies and various initial energy levels. This work presents COPE, an energy-aware Cooperative OPportunistic alErt diffusion scheme for trapped survivors to use during disaster scenarios to report their position and ease their rescue operation. It aims to maintain mobile devices functional for as long as possible for maximum network coverage until reaching proximate rescuers. COPE deals with mobile devices that come with an assortment of networks and aims to perform systematic network interface selection. Furthermore, it considers mobile devices with various energy levels and allows low-energy nodes to hold their charge for longer time with the support of high-energy nodes. A proof-of-concept implementation has been performed to study the doability and efficiency of COPE, and to highlight the lessons learned.

  4. Provider and pharmacist responses to warfarin drug–drug interaction alerts: a study of healthcare downstream of CPOE alerts

    Science.gov (United States)

    Boro, Maureen S; Korman, Nancy E; Davoren, J Ben

    2011-01-01

    Objective To categorize the appropriateness of provider and pharmacist responses to warfarin critical drug–drug interaction (cDDI) alerts, assess responses and actions to the cDDI, and determine the occurrence of warfarin adverse drug events (ADE) after alerts. Design An 18-month, retrospective study of acute care admissions at a single Veterans Affairs medical center using computerized provider order entry (CPOE). Measurements Patients included had at least one warfarin cDDI alert. Chart reviews included baseline laboratory values and demographics, provider actions, patient outcomes, and associated factors, including other interacting medications and number of simultaneously processed alerts. Results 137 admissions were included (133 unique patients). Amiodarone, vitamin E in a multivitamin, sulfamethoxazole, and levothyroxine accounted for 75% of warfarin cDDI. Provider responses were clinically appropriate in 19.7% of admissions and pharmacist responses were appropriate in 9.5% of admissions. There were 50 ADE (36.6% of admissions) with warfarin; 80% were rated as having no or mild clinical effect. An increased number of non-critical alerts at the time of the reference cDDI alert was the only variable associated with an inappropriate provider response (p=0.01). Limitations This study was limited by being a retrospective review and the possibility of confounding variables, such as other interacting medications. Conclusion The large number of CPOE alerts may lead to inappropriate responses by providers and pharmacists. The high rate of ADE suggests a need for improved medication management systems for patients on warfarin. This study highlights the possibility of alert fatigue contributing to the high prevalence of inappropriate alert over-ride text responses. PMID:22037888

  5. Report: Management Alert - Salary Increases for Certain Administratively Determined Positions

    Science.gov (United States)

    Report #18-N-0154, April 16, 2018. The purpose of this alert is to notify the EPA of certain factual info while our audit of the Office of the Administrator's (present and prior administrations) use of administratively determined positions continues.

  6. Office of Child Support and Enforcement (OCSE) State Wage Alerts

    Data.gov (United States)

    Social Security Administration — The OCSE State Wage Alert is a quarterly match which detects SSI overpayments by identifying unreported wage and unemployment data provided to the Office of Child...

  7. Usability of Smartphones for dose alerts

    International Nuclear Information System (INIS)

    Kaireit, T.; Stamm, G.; Wacker, F.K.; Hoeschen, C.

    2013-01-01

    Purpose: Smartphone apps for measuring ionizing radiation use the capability of (CMOS) camera chips to detect not only perceivable light but also electromagnetic wave radiation. The present study evaluates the accuracy of hardware and software and defines possible applications for the detection of X-ray radiation fields. Materials and Methods: 2 apps and 2 different devices were tested in comparison with a calibrated ionization chamber and a personal electronic dosimeter. A calibration curve was determined for dose rates between 12 700 μSv/h and 5.7 μSv/h generated by a C-arm system. Results: The measured scattered radiation produced by an Alderson-Rando phantom ranged from 117 μSv/h (at a distance of 2 m) to 5910 μSv/h (at a distance of 0.3 m) and was 1.4 times less than the values of the ionization chamber. The exposure rate for the operator's thyroid was within 4200 - 4400 μSv/h. We found a strong dependence of the measurements on the angulation of the Smartphone, especially for short distances from the phantom (at a distance of 0.3 m, a 45 rotation downwards in a vertical direction caused a decrease from 3000 μSv/h to 972 μSv/h, while an upwards rotation resulted in an increase to 5000 μSv/h). For a distance of 1 m, this effect was remarkably smaller. Conclusion: Smartphones can be used to detect ionizing radiation but showed limited accuracy and are heavily dependent on the angulation of the device. Qualitative measurements and utilization for dose alerts are possible. (orig.)

  8. [Usability of smartphones for dose alerts].

    Science.gov (United States)

    Kaireit, T; Stamm, G; Hoeschen, C; Wacker, F K

    2013-06-01

    Smartphone apps for measuring ionizing radiation use the capability of (CMOS) camera chips to detect not only perceivable light but also electromagnetic wave radiation. The present study evaluates the accuracy of hardware and software and defines possible applications for the detection of X-ray radiation fields. 2 apps and 2 different devices were tested in comparison with a calibrated ionization chamber and a personal electronic dosimeter. A calibration curve was determined for dose rates between 12 700 µSv/h and 5.7 µSv/h generated by a C-arm system. The measured scattered radiation produced by an Alderson-Rando phantom ranged from 117 µSv/h (at a distance of 2 m) to 5910 µSv/h (at a distance of 0.3 m) and was 1.4 times less than the values of the ionization chamber. The exposure rate for the operator's thyroid was within 4200 - 4400 µSv/h. We found a strong dependence of the measurements on the angulation of the Smartphone, especially for short distances from the phantom (at a distance of 0.3 m, a 45° rotation downwards in a vertical direction caused a decrease from 3000 µSv/h to 972 µSv/h, while an upwards rotation resulted in an increase to 5000 µSv/h). For a distance of 1 m, this effect was remarkably smaller. Smartphones can be used to detect ionizing radiation but showed limited accuracy and are heavily dependent on the angulation of the device. Qualitative measurements and utilization for dose alerts are possible. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Acute alerting effects of light: A systematic literature review.

    Science.gov (United States)

    Souman, Jan L; Tinga, Angelica M; Te Pas, Susan F; van Ee, Raymond; Vlaskamp, Björn N S

    2018-01-30

    Periodic, well timed exposure to light is important for our health and wellbeing. Light, in particular in the blue part of the spectrum, is thought to affect alertness both indirectly, by modifying circadian rhythms, and directly, giving rise to acute effects. We performed a systematic review of empirical studies on direct, acute effects of light on alertness to evaluate the reliability of these effects. In total, we identified 68 studies in which either light intensity, spectral distribution, or both were manipulated, and evaluated the effects on behavioral measures of alertness, either subjectively or measured in reaction time performance tasks. The results show that increasing the intensity of polychromatic white light has been found to increase subjective ratings of alertness in a majority of studies, though a substantial proportion of studies failed to find significant effects, possibly due to small sample sizes or high baseline light intensities. The effect of the color temperature of white light on subjective alertness is less clear. Some studies found increased alertness with higher color temperatures, but other studies reported no detrimental effects of filtering out the short wavelengths from the spectrum. Similarly, studies that used monochromatic light exposure showed no systematic pattern for the effects of blue light compared to longer wavelengths. Far fewer studies investigated the effects of light intensity or spectrum on alertness as measured with reaction time tasks and of those, very few reported significant effects. In general, the small sample sizes used in studies on acute alerting effects of light make it difficult to draw definitive conclusions and better powered studies are needed, especially studies that allow for the construction of dose-response curves. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Monitoring alert and drowsy states by modeling EEG source nonstationarity

    Science.gov (United States)

    Hsu, Sheng-Hsiou; Jung, Tzyy-Ping

    2017-10-01

    Objective. As a human brain performs various cognitive functions within ever-changing environments, states of the brain characterized by recorded brain activities such as electroencephalogram (EEG) are inevitably nonstationary. The challenges of analyzing the nonstationary EEG signals include finding neurocognitive sources that underlie different brain states and using EEG data to quantitatively assess the state changes. Approach. This study hypothesizes that brain activities under different states, e.g. levels of alertness, can be modeled as distinct compositions of statistically independent sources using independent component analysis (ICA). This study presents a framework to quantitatively assess the EEG source nonstationarity and estimate levels of alertness. The framework was tested against EEG data collected from 10 subjects performing a sustained-attention task in a driving simulator. Main results. Empirical results illustrate that EEG signals under alert versus drowsy states, indexed by reaction speeds to driving challenges, can be characterized by distinct ICA models. By quantifying the goodness-of-fit of each ICA model to the EEG data using the model deviation index (MDI), we found that MDIs were significantly correlated with the reaction speeds (r  =  -0.390 with alertness models and r  =  0.449 with drowsiness models) and the opposite correlations indicated that the two models accounted for sources in the alert and drowsy states, respectively. Based on the observed source nonstationarity, this study also proposes an online framework using a subject-specific ICA model trained with an initial (alert) state to track the level of alertness. For classification of alert against drowsy states, the proposed online framework achieved an averaged area-under-curve of 0.745 and compared favorably with a classic power-based approach. Significance. This ICA-based framework provides a new way to study changes of brain states and can be applied to

  11. The DOPA decarboxylase (DDC) gene is associated with alerting attention.

    Science.gov (United States)

    Zhu, Bi; Chen, Chuansheng; Moyzis, Robert K; Dong, Qi; Chen, Chunhui; He, Qinghua; Li, Jin; Li, Jun; Lei, Xuemei; Lin, Chongde

    2013-06-03

    DOPA decarboxylase (DDC) is involved in the synthesis of dopamine, norepinephrine and serotonin. It has been suggested that genes involved in the dopamine, norepinephrine, and cholinergic systems play an essential role in the efficiency of human attention networks. Attention refers to the cognitive process of obtaining and maintaining the alert state, orienting to sensory events, and regulating the conflicts of thoughts and behavior. The present study tested seven single nucleotide polymorphisms (SNPs) within the DDC gene for association with attention, which was assessed by the Attention Network Test to detect three networks of attention, including alerting, orienting, and executive attention, in a healthy Han Chinese sample (N=451). Association analysis for individual SNPs indicated that four of the seven SNPs (rs3887825, rs7786398, rs10499695, and rs6969081) were significantly associated with alerting attention. Haplotype-based association analysis revealed that alerting was associated with the haplotype G-A-T for SNPs rs7786398-rs10499695-rs6969081. These associations remained significant after correcting for multiple testing by max(T) permutation. No association was found for orienting and executive attention. This study provides the first evidence for the involvement of the DDC gene in alerting attention. A better understanding of the genetic basis of distinct attention networks would allow us to develop more effective diagnosis, treatment, and prevention of deficient or underdeveloped alerting attention as well as its related prevalent neuropsychiatric disorders. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Mobile Traffic Alert and Tourist Route Guidance System Design Using Geospatial Data

    Science.gov (United States)

    Bhattacharya, D.; Painho, M.; Mishra, S.; Gupta, A.

    2017-09-01

    The present study describes an integrated system for traffic data collection and alert warning. Geographical information based decision making related to traffic destinations and routes is proposed through the design. The system includes a geospatial database having profile relating to a user of a mobile device. The processing and understanding of scanned maps, other digital data input leads to route guidance. The system includes a server configured to receive traffic information relating to a route and location information relating to the mobile device. Server is configured to send a traffic alert to the mobile device when the traffic information and the location information indicate that the mobile device is traveling toward traffic congestion. Proposed system has geospatial and mobile data sets pertaining to Bangalore city in India. It is envisaged to be helpful for touristic purposes as a route guidance and alert relaying information system to tourists for proximity to sites worth seeing in a city they have entered into. The system is modular in architecture and the novelty lies in integration of different modules carrying different technologies for a complete traffic information system. Generic information processing and delivery system has been tested to be functional and speedy under test geospatial domains. In a restricted prototype model with geo-referenced route data required information has been delivered correctly over sustained trials to designated cell numbers, with average time frame of 27.5 seconds, maximum 50 and minimum 5 seconds. Traffic geo-data set trials testing is underway.

  13. MOBILE TRAFFIC ALERT AND TOURIST ROUTE GUIDANCE SYSTEM DESIGN USING GEOSPATIAL DATA

    Directory of Open Access Journals (Sweden)

    D. Bhattacharya

    2017-09-01

    Full Text Available The present study describes an integrated system for traffic data collection and alert warning. Geographical information based decision making related to traffic destinations and routes is proposed through the design. The system includes a geospatial database having profile relating to a user of a mobile device. The processing and understanding of scanned maps, other digital data input leads to route guidance. The system includes a server configured to receive traffic information relating to a route and location information relating to the mobile device. Server is configured to send a traffic alert to the mobile device when the traffic information and the location information indicate that the mobile device is traveling toward traffic congestion. Proposed system has geospatial and mobile data sets pertaining to Bangalore city in India. It is envisaged to be helpful for touristic purposes as a route guidance and alert relaying information system to tourists for proximity to sites worth seeing in a city they have entered into. The system is modular in architecture and the novelty lies in integration of different modules carrying different technologies for a complete traffic information system. Generic information processing and delivery system has been tested to be functional and speedy under test geospatial domains. In a restricted prototype model with geo-referenced route data required information has been delivered correctly over sustained trials to designated cell numbers, with average time frame of 27.5 seconds, maximum 50 and minimum 5 seconds. Traffic geo-data set trials testing is underway.

  14. Speech Auditory Alerts Promote Memory for Alerted Events in a Video-Simulated Self-Driving Car Ride.

    Science.gov (United States)

    Nees, Michael A; Helbein, Benji; Porter, Anna

    2016-05-01

    Auditory displays could be essential to helping drivers maintain situation awareness in autonomous vehicles, but to date, few or no studies have examined the effectiveness of different types of auditory displays for this application scenario. Recent advances in the development of autonomous vehicles (i.e., self-driving cars) have suggested that widespread automation of driving may be tenable in the near future. Drivers may be required to monitor the status of automation programs and vehicle conditions as they engage in secondary leisure or work tasks (entertainment, communication, etc.) in autonomous vehicles. An experiment compared memory for alerted events-a component of Level 1 situation awareness-using speech alerts, auditory icons, and a visual control condition during a video-simulated self-driving car ride with a visual secondary task. The alerts gave information about the vehicle's operating status and the driving scenario. Speech alerts resulted in better memory for alerted events. Both auditory display types resulted in less perceived effort devoted toward the study tasks but also greater perceived annoyance with the alerts. Speech auditory displays promoted Level 1 situation awareness during a simulation of a ride in a self-driving vehicle under routine conditions, but annoyance remains a concern with auditory displays. Speech auditory displays showed promise as a means of increasing Level 1 situation awareness of routine scenarios during an autonomous vehicle ride with an unrelated secondary task. © 2016, Human Factors and Ergonomics Society.

  15. Comparison of methods of alert acknowledgement by critical care clinicians in the ICU setting

    Directory of Open Access Journals (Sweden)

    Andrew M. Harrison

    2017-03-01

    Full Text Available Background Electronic Health Record (EHR-based sepsis alert systems have failed to demonstrate improvements in clinically meaningful endpoints. However, the effect of implementation barriers on the success of new sepsis alert systems is rarely explored. Objective To test the hypothesis time to severe sepsis alert acknowledgement by critical care clinicians in the ICU setting would be reduced using an EHR-based alert acknowledgement system compared to a text paging-based system. Study Design In one arm of this simulation study, real alerts for patients in the medical ICU were delivered to critical care clinicians through the EHR. In the other arm, simulated alerts were delivered through text paging. The primary outcome was time to alert acknowledgement. The secondary outcomes were a structured, mixed quantitative/qualitative survey and informal group interview. Results The alert acknowledgement rate from the severe sepsis alert system was 3% (N = 148 and 51% (N = 156 from simulated severe sepsis alerts through traditional text paging. Time to alert acknowledgement from the severe sepsis alert system was median 274 min (N = 5 and median 2 min (N = 80 from text paging. The response rate from the EHR-based alert system was insufficient to compare primary measures. However, secondary measures revealed important barriers. Conclusion Alert fatigue, interruption, human error, and information overload are barriers to alert and simulation studies in the ICU setting.

  16. Space Debris Alert System for Aviation

    Science.gov (United States)

    Sgobba, Tommaso

    2013-09-01

    Despite increasing efforts to accurately predict space debris re-entry, the exact time and location of re-entry is still very uncertain. Partially, this is due to a skipping effect uncontrolled spacecraft may experience as they enter the atmosphere at a shallow angle. Such effect difficult to model depends on atmospheric variations of density. When the bouncing off ends and atmospheric re-entry starts, the trajectory and the overall location of surviving fragments can be precisely predicted but the time to impact with ground, or to reach the airspace, becomes very short.Different is the case of a functional space system performing controlled re-entry. Suitable forecasts methods are available to clear air and maritime traffic from hazard areas (so-called traffic segregation).In US, following the Space Shuttle Columbia accident in 2003, a re-entry hazard areas location forecast system was putted in place for the specific case of major malfunction of a Reusable Launch Vehicles (RLV) at re-entry. The Shuttle Hazard Area to Aircraft Calculator (SHAAC) is a system based on ground equipment and software analyses and prediction tools, which require trained personnel and close coordination between the organization responsible for RLV operation (NASA for Shuttle) and the Federal Aviation Administration. The system very much relies on the operator's capability to determine that a major malfunction has occurred.This paper presents a US pending patent by the European Space Agency, which consists of a "smart fragment" using a GPS localizer together with pre- computed debris footprint area and direct broadcasting of such hazard areas.The risk for aviation from falling debris is very remote but catastrophic. Suspending flight over vast swath of airspace for every re-entering spacecraft or rocket upper stage, which is a weekly occurrence, would be extremely costly and disruptive.The Re-entry Direct Broadcasting Alert System (R- DBAS) is an original merging and evolution of the Re

  17. Optimizing the response to surveillance alerts in automated surveillance systems.

    Science.gov (United States)

    Izadi, Masoumeh; Buckeridge, David L

    2011-02-28

    Although much research effort has been directed toward refining algorithms for disease outbreak alerting, considerably less attention has been given to the response to alerts generated from statistical detection algorithms. Given the inherent inaccuracy in alerting, it is imperative to develop methods that help public health personnel identify optimal policies in response to alerts. This study evaluates the application of dynamic decision making models to the problem of responding to outbreak detection methods, using anthrax surveillance as an example. Adaptive optimization through approximate dynamic programming is used to generate a policy for decision making following outbreak detection. We investigate the degree to which the model can tolerate noise theoretically, in order to keep near optimal behavior. We also evaluate the policy from our model empirically and compare it with current approaches in routine public health practice for investigating alerts. Timeliness of outbreak confirmation and total costs associated with the decisions made are used as performance measures. Using our approach, on average, 80 per cent of outbreaks were confirmed prior to the fifth day of post-attack with considerably less cost compared to response strategies currently in use. Experimental results are also provided to illustrate the robustness of the adaptive optimization approach and to show the realization of the derived error bounds in practice. Copyright © 2011 John Wiley & Sons, Ltd.

  18. Infant Responsiveness, Alertness, Hemoglobin and Growth in Rural Sidama, Ethiopia

    Science.gov (United States)

    Aubuchon-Endsley, Nicki L.; Grant, Stephanie L.; Thomas, David G.; Kennedy, Tay S.; Berhanu, Getenesh; Stoecker, Barbara J.; Hubbs-Tait, Laura; Hambidge, K. Michael

    2011-01-01

    Several recent studies have supported relations between infant behavior (alertness and responsiveness) and nutrition (e.g. Dempsey 2008, Wachs et al 2005) in addition to investigating infant behavior within the context of changes in iron status over time (e.g. Black et al. 2004, Murray-Kolb & Beard 2009). Existing research is typically limited to investigation of the effects of a single vitamin or mineral and no studies have been found that examined the influence that early alertness and responsiveness have on growth in early infancy, despite the fact that relations between behavior and nutritional status may be bidirectional (Hulthén 2003). The current study used a sample of Ethiopian infants and investigated anthropometrics, hemoglobin, the frequency of alertness, and the frequency of responsiveness at 6 and 9 months of age. Six-month weight-for-age predicted 9-month frequency of alertness, while 6-month hemoglobin predicted 9-month frequency of responsiveness. Compared to responsive infants, non-responsive infants at 6 months remained more non-responsive at 9 months, though weight-for-age for both groups converged at 9 months. Results support relations between nutrition and behavior (alertness and responsiveness) and provide evidence of a potentially useful tool (the Laboratory Temperament Assessment Battery [Lab-TAB]) that was adapted to evaluate these relations in Ethiopia. PMID:22233352

  19. Best practices: an electronic drug alert program to improve safety in an accountable care environment.

    Science.gov (United States)

    Griesbach, Sara; Lustig, Adam; Malsin, Luanne; Carley, Blake; Westrich, Kimberly D; Dubois, Robert W

    2015-04-01

    potential adverse drug events were identified with baseline data from the DSAP initiatives, and nearly 8,000 were resolved by changes in prescribing.  Implications and additional thoughts from The Working Group on Optimizing Medication Therapy in Value-Based Healthcare were provided for the following categories: leveraging electronic health records, importance of data collection and reassessment, preventing alert fatigue utilizing various techniques, relevance to ACO quality measurement, and limitations of a retrospective system. While health information technologies have been recognized as a cornerstone for an ACO's success, additional research is needed on comparing these types of technological innovations. Future research should focus on reviewing comparable scoring criteria and alert systems utilized in a variety of ACOs. In addition, an examination of different data mining procedures used within different electronic health record platforms would prove useful to ACOs looking to improve the care of not only the subpopulations with specific metrics associated with them, but their patient population as a whole. The authors also highlight the need for additional research on health information exchanges, including the cost and resource requirements needed to successfully participate in these types of networks.

  20. Wireless alerting system using vibration for vehicles dashboard

    Science.gov (United States)

    Raj, Sweta; Rai, Shweta; Magaramagara, Wilbert; Sivacoumar, R.

    2017-11-01

    This paper aims at improving the engine life of any vehicle through a continuous measurement and monitoring of vital engine operational parameters and providing an effective alerting to drivers for any abnormality. Vehicles currently are using audio and visible alerting signals through alarms and light as a warning to the driver but these are not effective in noisy environments and during daylight. Through the use of the sense of feeling a driver can be alerted effectively. The need to no other vehicle parameter needs to be aided through the mobile display (phone).Thus a system is designed and implements to measure engine temperature, RPM, Oil level and Coolant level using appropriate sensors and a wireless communication (Bluetooth) is established to actuate a portable vibration control device and to read the different vehicle sensor readings through an android application for display and diagnosis.

  1. Dynamic malware containment under an epidemic model with alert

    Science.gov (United States)

    Zhang, Tianrui; Yang, Lu-Xing; Yang, Xiaofan; Wu, Yingbo; Tang, Yuan Yan

    2017-03-01

    Alerting at the early stage of malware invasion turns out to be an important complement to malware detection and elimination. This paper addresses the issue of how to dynamically contain the prevalence of malware at a lower cost, provided alerting is feasible. A controlled epidemic model with alert is established, and an optimal control problem based on the epidemic model is formulated. The optimality system for the optimal control problem is derived. The structure of an optimal control for the proposed optimal control problem is characterized under some conditions. Numerical examples show that the cost-efficiency of an optimal control strategy can be enhanced by adjusting the upper and lower bounds on admissible controls.

  2. Alert Workplace From Healthcare Workers' Perspective: Behavioral and Environmental Strategies to Improve Vigilance and Alertness in Healthcare Settings.

    Science.gov (United States)

    Sagah Zadeh, Rana; Shepley, Mardelle; Sadatsafavi, Hessam; Owora, Arthur Hamie; Krieger, Ana C

    2018-04-01

    This study aims to identify the behavioral and environmental strategies that healthcare workers view as helpful for managing sleepiness, improving alertness, and therefore optimizing workplace safety. Reduced alertness is a common issue in healthcare work environments and is associated with impaired cognitive performance and decision-making ability as well as increased errors and injuries. We surveyed 136 healthcare professionals at a primary care clinic, an acute care hospital, and a mental health clinic. Nonstructured, semistructured, and structured questionnaires were used to elicit relevant information which was analyzed using qualitative content analysis and logistic regression models, respectively. In order by frequency of endorsement: dietary intervention; physical mobility; cognitive, sensory, or social stimulation; personal lifestyle strategies; and rest/nap opportunities were reported as behavioral strategies used to address workplace alertness. Compared to other environmental features, daylight and thermal comfort were perceived to be more important to addressing workplace alertness ( p based guidelines is needed to address sleepiness and alertness to improve workplace safety in healthcare facilities.

  3. The agile alert system for gamma-ray transients

    International Nuclear Information System (INIS)

    Bulgarelli, A.; Trifoglio, M.; Gianotti, F.; Fioretti, V.; Tavani, M.; Argan, A.; Trois, A.; Scalise, E.; Parmiggiani, N.; Beneventano, D.; Chen, A. W.; Vercellone, S.; Pittori, C.; Verrecchia, F.; Lucarelli, F.; Santolamazza, P.; Fanari, G.; Giommi, P.; Longo, F.; Pellizzoni, A.

    2014-01-01

    In recent years, a new generation of space missions has offered great opportunities for discovery in high-energy astrophysics. In this article we focus on the scientific operations of the Gamma-Ray Imaging Detector (GRID) on board the AGILE space mission. AGILE-GRID, sensitive in the energy range of 30 MeV-30 GeV, has detected many γ-ray transients of both galactic and extragalactic origin. This work presents the AGILE innovative approach to fast γ-ray transient detection, which is a challenging task and a crucial part of the AGILE scientific program. The goals are to describe (1) the AGILE Gamma-Ray Alert System, (2) a new algorithm for blind search identification of transients within a short processing time, (3) the AGILE procedure for γ-ray transient alert management, and (4) the likelihood of ratio tests that are necessary to evaluate the post-trial statistical significance of the results. Special algorithms and an optimized sequence of tasks are necessary to reach our goal. Data are automatically analyzed at every orbital downlink by an alert pipeline operating on different timescales. As proper flux thresholds are exceeded, alerts are automatically generated and sent as SMS messages to cellular telephones, via e-mail, and via push notifications from an application for smartphones and tablets. These alerts are crosschecked with the results of two pipelines, and a manual analysis is performed. Being a small scientific-class mission, AGILE is characterized by optimization of both scientific analysis and ground-segment resources. The system is capable of generating alerts within two to three hours of a data downlink, an unprecedented reaction time in γ-ray astrophysics.

  4. CISN ShakeAlert Earthquake Early Warning System Monitoring Tools

    Science.gov (United States)

    Henson, I. H.; Allen, R. M.; Neuhauser, D. S.

    2015-12-01

    CISN ShakeAlert is a prototype earthquake early warning system being developed and tested by the California Integrated Seismic Network. The system has recently been expanded to support redundant data processing and communications. It now runs on six machines at three locations with ten Apache ActiveMQ message brokers linking together 18 waveform processors, 12 event association processes and 4 Decision Module alert processes. The system ingests waveform data from about 500 stations and generates many thousands of triggers per day, from which a small portion produce earthquake alerts. We have developed interactive web browser system-monitoring tools that display near real time state-of-health and performance information. This includes station availability, trigger statistics, communication and alert latencies. Connections to regional earthquake catalogs provide a rapid assessment of the Decision Module hypocenter accuracy. Historical performance can be evaluated, including statistics for hypocenter and origin time accuracy and alert time latencies for different time periods, magnitude ranges and geographic regions. For the ElarmS event associator, individual earthquake processing histories can be examined, including details of the transmission and processing latencies associated with individual P-wave triggers. Individual station trigger and latency statistics are available. Detailed information about the ElarmS trigger association process for both alerted events and rejected events is also available. The Google Web Toolkit and Map API have been used to develop interactive web pages that link tabular and geographic information. Statistical analysis is provided by the R-Statistics System linked to a PostgreSQL database.

  5. The agile alert system for gamma-ray transients

    Energy Technology Data Exchange (ETDEWEB)

    Bulgarelli, A.; Trifoglio, M.; Gianotti, F.; Fioretti, V. [INAF/IASF-Bologna, Via Gobetti 101, I-40129 Bologna (Italy); Tavani, M.; Argan, A.; Trois, A.; Scalise, E. [INAF/IASF-Roma, Via del Fosso del Cavaliere 100, I-00133 Roma (Italy); Parmiggiani, N.; Beneventano, D. [University of Modena and Reggio Emilia, Dipartimento di Science e Metodi dell' Ingegneria (Italy); Chen, A. W. [INAF/IASF-Milano, Via E. Bassini 15, I-20133 Milano (Italy); Vercellone, S. [School of Physics, University of the Witwatersrand, Johannesburg Wits 2050 (South Africa); Pittori, C.; Verrecchia, F.; Lucarelli, F.; Santolamazza, P.; Fanari, G.; Giommi, P. [INAF/IASF-Palermo, Via U. La Malfa 153, I-90146 Palermo (Italy); Longo, F. [ASI-ASDC, Via G. Galilei, I-00044 Frascati (Roma) (Italy); Pellizzoni, A. [INFN Trieste, I-34127 Trieste (Italy); and others

    2014-01-20

    In recent years, a new generation of space missions has offered great opportunities for discovery in high-energy astrophysics. In this article we focus on the scientific operations of the Gamma-Ray Imaging Detector (GRID) on board the AGILE space mission. AGILE-GRID, sensitive in the energy range of 30 MeV-30 GeV, has detected many γ-ray transients of both galactic and extragalactic origin. This work presents the AGILE innovative approach to fast γ-ray transient detection, which is a challenging task and a crucial part of the AGILE scientific program. The goals are to describe (1) the AGILE Gamma-Ray Alert System, (2) a new algorithm for blind search identification of transients within a short processing time, (3) the AGILE procedure for γ-ray transient alert management, and (4) the likelihood of ratio tests that are necessary to evaluate the post-trial statistical significance of the results. Special algorithms and an optimized sequence of tasks are necessary to reach our goal. Data are automatically analyzed at every orbital downlink by an alert pipeline operating on different timescales. As proper flux thresholds are exceeded, alerts are automatically generated and sent as SMS messages to cellular telephones, via e-mail, and via push notifications from an application for smartphones and tablets. These alerts are crosschecked with the results of two pipelines, and a manual analysis is performed. Being a small scientific-class mission, AGILE is characterized by optimization of both scientific analysis and ground-segment resources. The system is capable of generating alerts within two to three hours of a data downlink, an unprecedented reaction time in γ-ray astrophysics.

  6. The AGILE Alert System for Gamma-Ray Transients

    Science.gov (United States)

    Bulgarelli, A.; Trifoglio, M.; Gianotti, F.; Tavani, M.; Parmiggiani, N.; Fioretti, V.; Chen, A. W.; Vercellone, S.; Pittori, C.; Verrecchia, F.; Lucarelli, F.; Santolamazza, P.; Fanari, G.; Giommi, P.; Beneventano, D.; Argan, A.; Trois, A.; Scalise, E.; Longo, F.; Pellizzoni, A.; Pucella, G.; Colafrancesco, S.; Conforti, V.; Tempesta, P.; Cerone, M.; Sabatini, P.; Annoni, G.; Valentini, G.; Salotti, L.

    2014-01-01

    In recent years, a new generation of space missions has offered great opportunities for discovery in high-energy astrophysics. In this article we focus on the scientific operations of the Gamma-Ray Imaging Detector (GRID) on board the AGILE space mission. AGILE-GRID, sensitive in the energy range of 30 MeV-30 GeV, has detected many γ-ray transients of both galactic and extragalactic origin. This work presents the AGILE innovative approach to fast γ-ray transient detection, which is a challenging task and a crucial part of the AGILE scientific program. The goals are to describe (1) the AGILE Gamma-Ray Alert System, (2) a new algorithm for blind search identification of transients within a short processing time, (3) the AGILE procedure for γ-ray transient alert management, and (4) the likelihood of ratio tests that are necessary to evaluate the post-trial statistical significance of the results. Special algorithms and an optimized sequence of tasks are necessary to reach our goal. Data are automatically analyzed at every orbital downlink by an alert pipeline operating on different timescales. As proper flux thresholds are exceeded, alerts are automatically generated and sent as SMS messages to cellular telephones, via e-mail, and via push notifications from an application for smartphones and tablets. These alerts are crosschecked with the results of two pipelines, and a manual analysis is performed. Being a small scientific-class mission, AGILE is characterized by optimization of both scientific analysis and ground-segment resources. The system is capable of generating alerts within two to three hours of a data downlink, an unprecedented reaction time in γ-ray astrophysics.

  7. Mutagenic and carcinogenic structural alerts and their mechanisms of action.

    Science.gov (United States)

    Plošnik, Alja; Vračko, Marjan; Dolenc, Marija Sollner

    2016-09-01

    Knowing the mutagenic and carcinogenic properties of chemicals is very important for their hazard (and risk) assessment. One of the crucial events that trigger genotoxic and sometimes carcinogenic effects is the forming of adducts between chemical compounds and nucleic acids and histones. This review takes a look at the mechanisms related to specific functional groups (structural alerts or toxicophores) that may trigger genotoxic or epigenetic effects in the cells. We present up-to-date information about defined structural alerts with their mechanisms and the software based on this knowledge (QSAR models and classification schemes).

  8. Hanford Site Emergency Alerting System siren testing report

    International Nuclear Information System (INIS)

    Weidner, L.B.

    1997-01-01

    The purpose of the test was to determine the effective coverage of the proposed upgrades to the existing Hanford Site Emergency Alerting System (HSEAS). The upgrades are to enhance the existing HSEAS along the Columbia River from the Vernita Bridge to the White Bluffs Boat Launch as well as install a new alerting system in the 400 Area on the Hanford Site. Five siren sites along the Columbia River and two sites in the 400 Area were tested to determine the site locations that will provide the desired coverage

  9. Geo-targeted Weather Alerts Coming to Millions of Mobile Devices

    Science.gov (United States)

    Gerber, M.

    2011-12-01

    The Personal Localized Alert Network (PLAN), aka Commercial Mobile Alert System (CMAS), is readying for roll out and will be broadcasting emergency public alerts to millions of cell phones by the middle of 2012. Learn how the National Weather Serivce (NWS) is supplying PLAN with geo-referenced weather alert information in the industry standard Common Alerting Protocol (CAP) format and how you can access this same information for integration with mobile devices, other consumer electronics, and decision support systems. Information will also be provided on the NWS' new collaborative venue that encourages wide participation in the evolution and use of NWS CAP alerts in a variety of applications.

  10. Reduced Effectiveness of Interruptive Drug-Drug Interaction Alerts after Conversion to a Commercial Electronic Health Record.

    Science.gov (United States)

    Wright, Adam; Aaron, Skye; Seger, Diane L; Samal, Lipika; Schiff, Gordon D; Bates, David W

    2018-05-15

    Drug-drug interaction (DDI) alerts in electronic health records (EHRs) can help prevent adverse drug events, but such alerts are frequently overridden, raising concerns about their clinical usefulness and contribution to alert fatigue. To study the effect of conversion to a commercial EHR on DDI alert and acceptance rates. Two before-and-after studies. 3277 clinicians who received a DDI alert in the outpatient setting. Introduction of a new, commercial EHR and subsequent adjustment of DDI alerting criteria. Alert burden and proportion of alerts accepted. Overall interruptive DDI alert burden increased by a factor of 6 from the legacy EHR to the commercial EHR. The acceptance rate for the most severe alerts fell from 100 to 8.4%, and from 29.3 to 7.5% for medium severity alerts (P fell by 50.5%, and acceptance of Tier 1 alerts rose from 9.1 to 12.7% (P < 0.01). Changing from a highly tailored DDI alerting system to a more general one as part of an EHR conversion decreased acceptance of DDI alerts and increased alert burden on users. The decrease in acceptance rates cannot be fully explained by differences in the clinical knowledge base, nor can it be fully explained by alert fatigue associated with increased alert burden. Instead, workflow factors probably predominate, including timing of alerts in the prescribing process, lack of differentiation of more and less severe alerts, and features of how users interact with alerts.

  11. 北方地区应用太阳能辅助土壤源热泵效能分析%Efficiency Analysis of Utilizing Solar-assisted Ground Source Heat Pump in the Northern China

    Institute of Scientific and Technical Information of China (English)

    赵金秀

    2015-01-01

    针对北方寒冷地区气候特点,指出了太阳能辅助土壤源热泵系统相对于单独的土壤源热泵或单独的太阳能应用的技术特点。对北方寒冷地区某学校综合楼建筑进行了太阳能辅助土壤源热泵系统设计;并针对该建筑采用太阳能辅助土壤源热泵系统、采用单独的土壤源热泵系统或采用传统采暖空调系统,从三者经济效益、社会效益、环境效益等方面进行了比较,从而体现了太阳能辅助土壤源热泵系统相对于单独的土壤源热泵系统或传统采暖空调系统的高效、经济、节能、环保等优异性。%For the cold climate characteristics of the Northern China, the paper introduces the technical characteristics of solar-assisted ground source heat pump system relative to the separate ground source heat pump system or the separate solar energy application. For a complex building of a university in the cold northern area, the solar -assisted ground source heat pump system is designed, and economic benefits, social benefits, environmental benefits and other aspects about using the solar-assisted ground source heat pump system or using the ground source heat pump system alone or using the traditional air conditioning system are compared, thus reflects the excellent efficiency, cost-saving and energy -saving characteristics, and environmental protection about the solar assisted ground source heat pump system.

  12. FAB (Functionally Alert Behavior Strategies) to Improve Self-Control

    Science.gov (United States)

    Pagano, John

    2015-01-01

    This paper describes the FAB (Functionally Alert Behavior) Strategies approach to improve behavior in children and adolescents with complex behavioral challenges. FAB Strategies include evidence-based environmental adaptations, sensory modulation, positive behavioral support, and physical self-regulation strategies. FAB Strategies can be used by…

  13. Do repeated rumble strip hits improve driver alertness?

    NARCIS (Netherlands)

    Watling, C.N.; Akerstedt, T.; Kecklund, L.G.; Anund, A.

    2016-01-01

    Driving while sleepy is associated with increased crash risk. Rumble strips are designed to alert a sleepy or inattentive driver when they deviate outside their driving lane. The current study sought to examine the effects of repeated rumble strip hits on levels of physiological and subjective

  14. 44 CFR 208.36 - Reimbursement for Alert.

    Science.gov (United States)

    2010-10-01

    ... § 208.41 of this part. (4) Food and beverages for Task Force Members and Support Specialists when DHS does not provide meals during the Alert. DHS will limit food and beverage reimbursement to the amount... where such food and beverages were provided, multiplied by the number of personnel who received them. (b...

  15. Global Trade Alert | CRDI - Centre de recherches pour le ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Global Trade Alert (GTA) will provide information in real time on national measures taken during the current global economic downturn that are likely to discriminate against foreign commerce. GTA will complement and go beyond World Trade Organization (WTO) and World Bank monitoring initiatives by identifying affected ...

  16. Patient Blood Pressure and Pulse Rate Monitoring With an Alert ...

    African Journals Online (AJOL)

    2012-12-01

    Dec 1, 2012 ... an Alert System Using the Omron 790it Blood Pressure. Monitor ... detailed medical information on the vital signs of patients and will save many lives that may be lost. Keywords: Omron .... at rest, in beats per minute (BPM):.

  17. Testing and Performance of UFFO Burst Alert & Trigger Telescope

    DEFF Research Database (Denmark)

    Rípa, Jakub; Bin Kim, Min; Lee, Jik

    2014-01-01

    The Ultra-Fast Flash Observatory pathfinder (UFFO-p) is a new space mission dedicated to detect Gamma-Ray Bursts (GRBs) and rapidly follow their afterglows in order to provide early optical/ultraviolet measurements. A GRB location is determined in a few seconds by the UFFO Burst Alert & Trigger t...

  18. 47 CFR 80.1114 - False distress alerts.

    Science.gov (United States)

    2010-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Global Maritime Distress and Safety System (GMDSS) Operating Procedures for Distress and Safety Communications § 80.1114 False distress alerts. The provisions of §§ 80.334 and 80.335 apply to...

  19. 47 CFR 80.1113 - Transmission of a distress alert.

    Science.gov (United States)

    2010-10-01

    ... Section 80.1113 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Global Maritime Distress and Safety System (GMDSS) Operating Procedures for Distress and Safety Communications § 80.1113 Transmission of a distress alert. (a) The...

  20. Comparing alertness and injury severity following motor vehicular ...

    African Journals Online (AJOL)

    Background: From casual observation of injury patterns in Motor Vehicular Accidents (MVAs), it was sometimes observed that if the victim had been more alert and reacts protectively, injury severity might be reduced. Protective response is often expected to minimize the severity of injuries. Objective: To determine the ...

  1. Abonnez-vous aux alertes de financement | CRDI - Centre de ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Afrique subsaharienne. Si vous ne voulez plus recevoir les alertes de financement, vous pouvez toujours vous désabonner. Ce que nous faisons · Financement · Ressources · À propos du CRDI. Savoir. Innovation. Solutions. Carrières · Communiquez avec nous · Plan du site. Abonnez-vous à notre bulletin pour recevoir les ...

  2. Alerting, Orienting, and Executive Attention in Children with ADHD

    Science.gov (United States)

    Mullane, Jennifer C.; Corkum, Penny V.; Klein, Raymond M.; McLaughlin, Elizabeth N.; Lawrence, Michael A.

    2011-01-01

    Objective: This study evaluated the alerting, orienting, and executive attention abilities of children with ADHD and their typically developing (TD) peers using a modified version of the adult attention network test (ANT-I). Method: A total of 25 children with ADHD, Combined Type (ADHD-C, mean age = 9.20 years), 20 children with ADHD,…

  3. An Investigation of an RFID-based Patient-tracking and Mobile Alert System

    Directory of Open Access Journals (Sweden)

    C.L. Yeung

    2011-02-01

    Full Text Available In the modern era, patient health is no longer the only concern for hospitals. Hospitals have to bear the responsibility of the patient safety and the patient comfort. However, due to the overcrowded and understaffed clinical areas with complex workflow patterns, there are different forms of medical care errors arisen in the healthcare system. According to recent statistic from World Health Organization, ten of milions of patient around the world are injured or dead every yearas a result of incorrect medical care. Rroughly 10% patients admitted to hospital in developed countries suffered some forms of medical care errors or medical adverse events. It is about 1.4 million of world population.In order to enhance the patient safety and patient comfort in the current medical service system, an RFID‐based Patient Tracking and Mobile Alert System integrated with information communications technology was designed and developed. Apart from identifying different patient’s whereabouts, instant alerts are generated through mobile devices so as to enhance patients’ safety and comfort. With a view of investigating the feasibility of RFID and mobile technology in the healthcare environment, a pilot study was conducted in Mindset Club in the Castle Peak Hospital in Hong Kong.

  4. Evaluation of health alerts from an early illness warning system in independent living.

    Science.gov (United States)

    Rantz, Marilyn J; Scott, Susan D; Miller, Steven J; Skubic, Marjorie; Phillips, Lorraine; Alexander, Greg; Koopman, Richelle J; Musterman, Katy; Back, Jessica

    2013-06-01

    Passive sensor networks were deployed in independent living apartments to monitor older adults in their home environments to detect signs of impending illness and alert clinicians so they can intervene and prevent or delay significant changes in health or functional status. A retrospective qualitative deductive content analysis was undertaken to refine health alerts to improve clinical relevance to clinicians as they use alerts in their normal workflow of routine care delivery to older adults. Clinicians completed written free-text boxes to describe actions taken (or not) as a result of each alert; they also rated the clinical significance (relevance) of each health alert on a scale of 1 to 5. Two samples of the clinician's written responses to the health alerts were analyzed after alert algorithms had been adjusted based on results of a pilot study using health alerts to enhance clinical decision-making. In the first sample, a total of 663 comments were generated by seven clinicians in response to 385 unique alerts; there are more comments than alerts because more than one clinician rated the same alert. The second sample had a total of 142 comments produced by three clinicians in response to 88 distinct alerts. The overall clinical relevance of the alerts, as judged by the content of the qualitative comments by clinicians for each alert, improved from 33.3% of the alerts in the first sample classified as clinically relevant to 43.2% in the second. The goal is to produce clinically relevant alerts that clinicians find useful in daily practice. The evaluation methods used are described to assist others as they consider building and iteratively refining health alerts to enhance clinical decision making.

  5. What is optimal timing for trauma team alerts? A retrospective observational study of alert timing effects on the initial management of trauma patients

    Directory of Open Access Journals (Sweden)

    Lillebo B

    2012-08-01

    Full Text Available Borge Lillebo,1 Andreas Seim,2 Ole-Petter Vinjevoll,3 Oddvar Uleberg31Norwegian EHR Research Centre, Department of Neuroscience, Faculty of Medicine, Norwegian University of Science and Technology, Trondheim, Norway; 2Department of Computer and Information Science, Faculty of Information Technology, Mathematics and Electrical Engineering, NTNU, Trondheim, Norway; 3Department of Anaesthesia and Emergency Medicine, St Olav's University Hospital, Trondheim, NorwayBackground: Trauma teams improve the initial management of trauma patients. Optimal timing of trauma alerts could improve team preparedness and performance while also limiting adverse ripple effects throughout the hospital. The purpose of this study was to evaluate how timing of trauma team activation and notification affects initial in-hospital management of trauma patients.Methods: Data from a single hospital trauma care quality registry were matched with data from a trauma team alert log. The time from patient arrival to chest X-ray, and the emergency department length of stay were compared with the timing of trauma team activations and whether or not trauma team members received a preactivation notification.Results: In 2009, the trauma team was activated 352 times; 269 times met the inclusion criteria. There were statistically significant differences in time to chest X-ray for differently timed trauma team activations (P = 0.003. Median time to chest X-ray for teams activated 15–20 minutes prearrival was 5 minutes, and 8 minutes for teams activated <5 minutes before patient arrival. Timing had no effect on length of stay in the emergency department (P = 0.694. We found no effect of preactivation notification on time to chest X-ray (P = 0.474 or length of stay (P = 0.684.Conclusion: Proactive trauma team activation improved the initial management of trauma patients. Trauma teams should be activated prior to patient arrival.Keywords: emergency medical service communication systems

  6. Emergency Communications: The Emergency Alert System (EAS) and All-Hazard Warnings

    National Research Council Canada - National Science Library

    Moore, Linda K; Reese, Shawn

    2005-01-01

    ... tested. Much has been accomplished in recent years but the current hodgepodge of warning and alert systems is inadequate for fully alerting the public about terrorist attacks or natural disasters...

  7. The relations between de-alerting nuclear force and nuclear strategy

    International Nuclear Information System (INIS)

    Li Zhimin

    2001-01-01

    De-alerting nuclear force is a hot-point issue in recent years. The relations between de-alerting and strategy (including nuclear force, target doctrine and use principle et al.), stability, advanced conventional force and NMD of the United States are analyzed, the impact of de-alerting on Chinese nuclear force were discussed and the proposal of de-alerting by stages is presented

  8. 太阳能-地源热泵复合系统在医疗建筑中的应用分析%Application analysis of solar ground-source heat pump composite system to medical building

    Institute of Scientific and Technical Information of China (English)

    高世康; 卢志鹏

    2017-01-01

    太阳能-地源热泵复合系统具有良好的节能效果和运行特性,本文利用TRNSYS分析其应用于山东某医院综合楼的可行性,并分析其与常规系统(城市热网配套+冷水机组)的全寿命周期成本.分析结果表明,太阳能-地源热泵复合系统的全寿命周期成本比常规系统节省26.4%,在2.16年之后,太阳能-地源热泵复合系统经济性优势明显.%The solar ground-source heat pump composite system has good energy-saving effect and operation characteristic.The feasibility of its application to one medical building in Shandong is analyzed using TRNSYS, and the life cycle cost of solar ground-source heat pump composite system and the conventional system of urban network supporting & chiller is analyzed.The analysis results show that the former life cycle cost can be saved by 26.4% compared with the latter, and 2.16 years later, the solar ground-source heat pump composite system will have evident economy trend.

  9. 太阳能耦合地源热泵供暖系统的实验研究%Experimental Study on Heating System of Solar Coupled Ground Source Heat Pump

    Institute of Scientific and Technical Information of China (English)

    智超英; 赵宇含

    2017-01-01

    太阳能耦合地源热泵系统的设计以太阳能为辅助、地源热泵为主,最大化地利用太阳能资源,在满足地板采暖制备的情况下,富裕的热量可以补充到生活用水当中.通过实验验证了太阳能耦合地源热泵供暖系统可以有效恢复土壤温度,提高机组性能系数,实现热泵长期稳定的运行.%The design of solar coupled ground source heat pump system is based on solar energy and ground source heat pump.The system can maximize solar energy utilization in the preparation of floor heating.Rich heat can be added to the life water.This paper introduces the solar coupled ground source heat pump heating system.The experiment proves that the system can effectively restore the soil temperature, improve the performance coefficient of the crew, and realize the long-term stable operation of the heat pump.

  10. 地源热泵与太阳能联合供热系统集热器面积优化的研究%Collector Area Optimization of Ground Source Heat Pump and Solar Combined Heating System

    Institute of Scientific and Technical Information of China (English)

    智超英; 赵宇含

    2018-01-01

    This paper mainly analyzes various influence factors on heat collector area of the ground source heat pump and solar combined heating system, studies the relationship of the cost of solar heat collection system,ground source heat pump operating costs per square meter,the maximum net benefit and solar collector area. In one run cycle,considering the maximum income,solar heating guarantee rate and ground source heat pump operating costs per square meter, the collector area of the combined heating system is optimized finally.%分析影响地源热泵与太阳能联合供热系统集热器面积的各种因素,研究太阳能集热系统造价、地源热泵每平方米运行费用、最大净受益、太阳能集热器面积相互间的关系.在一个循环周期内参考最大净收益,利用太阳能采暖保证率和地源热泵每平方米的运行费用的统计数据,最终联合供热系统的集热器面积达到最优.

  11. 太阳能-土壤源热泵复合系统优化与性能分析%System Optimization and Performance Analysis of Solar Energy and Ground-source Heat Pump Hybrid System

    Institute of Scientific and Technical Information of China (English)

    丁力勤

    2016-01-01

    本文利用瞬时系统模拟软件(Trnsys)搭建了常规土壤源热泵系统及太阳能-土壤源热泵并联复合式系统的模型,并根据不同集热器单位面积流量和水箱体积等参数进行了模拟计算。结果表明,土壤源热泵系统性能系数达3.6~3.8,具有明显的节能优势。%The models of ground-source heat pump system and the solar energy and ground-source heat pump shunt-wound hybrid system have been built by transient system (Trnsys) simulation software, and the simulation calculation has been processed according to the flow rate per unit area and water tank volume for different collectors. According to the simulation results, the coefficient of performance of the ground-source heat pump system is 3.6~3.8, and the system has advantages on energy saving.

  12. Discriminating between true-positive and false-positive clinical mastitis alerts from automatic milking systems

    NARCIS (Netherlands)

    Steeneveld, W.; Gaag, van der L.C.; Ouweltjes, W.; Mollenhorst, H.; Hogeveen, H.

    2010-01-01

    Automatic milking systems (AMS) generate alert lists reporting cows likely to have clinical mastitis (CM). Dutch farmers indicated that they use non-AMS cow information or the detailed alert information from the AMS to decide whether to check an alerted cow for CM. However, it is not yet known to

  13. Self-Alert Training: Volitional Modulation of Autonomic Arousal Improves Sustained Attention

    Science.gov (United States)

    O'Connell, Redmond G.; Bellgrove, Mark A.; Dockree, Paul M.; Lau, Adam; Fitzgerald, Michael; Robertson, Ian H.

    2008-01-01

    The present study examines a new alertness training strategy (Self-Alert Training, SAT) designed to explore the relationship between the top-down control processes governing arousal and sustained attention. In order to maximally target frontal control systems SAT combines a previously validated behavioural self-alerting technique [Robertson, I.…

  14. 75 FR 81556 - Solicitation of New Safe Harbors and Special Fraud Alerts

    Science.gov (United States)

    2010-12-28

    ... statute (section 1128B(b) of the Social Security Act), as well as developing new OIG Special Fraud Alerts... of New Safe Harbors and Special Fraud Alerts AGENCY: Office of Inspector General (OIG), HHS. ACTION... the public on recommendations for developing new or revised safe harbors and Special Fraud Alerts...

  15. 77 FR 76434 - Solicitation of New Safe Harbors and Special Fraud Alerts

    Science.gov (United States)

    2012-12-28

    ... statute (section 1128B(b) of the Social Security Act), as well as developing new OIG Special Fraud Alerts... of New Safe Harbors and Special Fraud Alerts AGENCY: Office of Inspector General (OIG), HHS. ACTION... revised safe harbors and Special Fraud Alerts. Please assist us by referencing the file code OIG-121-N...

  16. 78 FR 78807 - Solicitation of New Safe Harbors and Special Fraud Alerts

    Science.gov (United States)

    2013-12-27

    ... statute (section 1128B(b) of the Social Security Act), as well as developing new OIG Special Fraud Alerts... of New Safe Harbors and Special Fraud Alerts AGENCY: Office of Inspector General (OIG), HHS. ACTION... revised safe harbors and Special Fraud Alerts. Please assist us by referencing the file code OIG-122-N...

  17. Reduction in alert fatigue in an assisted electronic prescribing system, through the Lean Six Sigma methodology.

    Science.gov (United States)

    Cuéllar Monreal, Mª Jesús; Reig Aguado, Jorge; Font Noguera, Isabel; Poveda Andrés, José Luis

    2017-01-01

    To reduce the alert fatigue in our Assisted Electronic Prescribing System (AEPS), through the Lean Six Sigma (LSS) methodology. An observational (transversal) and retrospective study, in a general hospital with 850 beds and AEPS. The LSS methodology was followed in order to evaluate the alert fatigue situation in the AEPS system, to implement improvements, and to assess outcomes. The alerts generated during two trimesters studied (before and after the intervention) were analyzed. In order to measure the qualitative indicators, the most frequent alert types were analyzed, as well as the molecules responsible for over 50% of each type of alert. The action by the prescriber was analyzed in a sample of 496 prescriptions that generated such alerts. For each type of alert and molecule, there was a prioritization of the improvements to be implemented according to the alert generated and its quality. A second survey evaluated the pharmacist action for the alerts most highly valued by physicians. The problem, the objective, the work team and the project schedule were defined. A survey was designed in order to understand the opinion of the client about the alert system in the program. Based on the surveys collected (n = 136), the critical characteristics and the quanti/qualitative indicators were defined. Sixty (60) fields in the alert system were modified, corresponding to 32 molecules, and this led to a 28% reduction in the total number of alerts. Regarding quality indicators, false po sitive results were reduced by 25% (p < 0.05), 100% of those alerts ignored with justification were sustained, and there were no significant differences in user adherence to the system. The project improvements and outcomes were reviewed by the work team. LSS methodology has demonstrated being a valid tool for the quantitative and qualitative improvement of the alert system in an Assisted Electronic Prescription Program, thus reducing alert fatigue. Copyright AULA MEDICA EDICIONES 2014

  18. A deep-learning-based emergency alert system

    Directory of Open Access Journals (Sweden)

    Byungseok Kang

    2016-06-01

    Full Text Available Emergency alert systems serve as a critical link in the chain of crisis communication, and they are essential to minimize loss during emergencies. Acts of terrorism and violence, chemical spills, amber alerts, nuclear facility problems, weather-related emergencies, flu pandemics, and other emergencies all require those responsible such as government officials, building managers, and university administrators to be able to quickly and reliably distribute emergency information to the public. This paper presents our design of a deep-learning-based emergency warning system. The proposed system is considered suitable for application in existing infrastructure such as closed-circuit television and other monitoring devices. The experimental results show that in most cases, our system immediately detects emergencies such as car accidents and natural disasters.

  19. Brain-computer interface for alertness estimation and improving

    Science.gov (United States)

    Hramov, Alexander; Maksimenko, Vladimir; Hramova, Marina

    2018-02-01

    Using wavelet analysis of the signals of electrical brain activity (EEG), we study the processes of neural activity, associated with perception of visual stimuli. We demonstrate that the brain can process visual stimuli in two scenarios: (i) perception is characterized by destruction of the alpha-waves and increase in the high-frequency (beta) activity, (ii) the beta-rhythm is not well pronounced, while the alpha-wave energy remains unchanged. The special experiments show that the motivation factor initiates the first scenario, explained by the increasing alertness. Based on the obtained results we build the brain-computer interface and demonstrate how the degree of the alertness can be estimated and controlled in real experiment.

  20. ECG Holter monitor with alert system and mobile application

    Science.gov (United States)

    Teron, Abigail C.; Rivera, Pedro A.; Goenaga, Miguel A.

    2016-05-01

    This paper proposes a new approach on the Holter monitor by creating a portable Electrocardiogram (ECG) Holter monitor that will alert the user by detecting abnormal heart beats using a digital signal processing software. The alarm will be triggered when the patient experiences arrhythmias such as bradycardia and tachycardia. The equipment is simple, comfortable and small in size that fit in the hand. It can be used at any time and any moment by placing three leads to the person's chest which is connected to an electronic circuit. The ECG data will be transmitted via Bluetooth to the memory of a selected mobile phone using an application that will store the collected data for up to 24 hrs. The arrhythmia is identified by comparing the reference signals with the user's signal. The diagnostic results demonstrate that the ECG Holter monitor alerts the user when an arrhythmia is detected thru the Holter monitor and mobile application.

  1. SC-228 Inclusion of DAA Warning Alert for TCAS Interoperability

    Science.gov (United States)

    Fern, Lisa

    2016-01-01

    This white paper summarizes NASA research results that have informed Special Committee 228 (SC-228) discussions and decisions regarding the inclusion of a warning-level alert within the detect and avoid (DAA) alerting structure for unmanned aircraft systems (UAS). For UAS, the removal of the pilot from onboard the aircraft has eliminated the ability of the ground-based pilot in command (PIC) to use out-the-window visual information to make judgments about a potential threat of a loss of well clear with another aircraft. As a result, the DAA traffic display will be the primary source of information that the PIC can use to execute the three primary well clear functions: 1) detect a potential loss of well clear, 2) determine a resolution maneuver, and 3) upload that maneuver to the aircraft via the ground control station (GCS). In addition, pilots are required to coordinate with air traffic control (ATC) prior to maneuvering off of their approved flight plan. In determining an appropriate resolution maneuver to avoid a loss of well clear, the PIC must decide both when and how to maneuver, and both the timeliness and the accuracy (i.e., correctness) of the maneuver are critical to reducing the likelihood and/or severity of a loss of well clear. Alerting information is one of three critical components of the DAA display, along with traffic information elements (e.g., relative heading, speed and altitude) and maneuver guidance. Alerting information and maneuver guidance, in particular, have been found to have a significant impact, both statistically and practically, on pilots' ability to avoid and minimize the severity of losses of well clear While all three display components are key to pilots performing the traffic avoidance task of remaining well clear, in general, alerting information provides crucial information about when a resolution maneuver is required while maneuver guidance assists the pilot in determining how best to maneuver. A fundamental task of the DAA

  2. Microcontroller based driver alertness detection systems to detect drowsiness

    Science.gov (United States)

    Adenin, Hasibah; Zahari, Rahimi; Lim, Tiong Hoo

    2018-04-01

    The advancement of embedded system for detecting and preventing drowsiness in a vehicle is a major challenge for road traffic accident systems. To prevent drowsiness while driving, it is necessary to have an alert system that can detect a decline in driver concentration and send a signal to the driver. Studies have shown that traffc accidents usually occur when the driver is distracted while driving. In this paper, we have reviewed a number of detection systems to monitor the concentration of a car driver and propose a portable Driver Alertness Detection System (DADS) to determine the level of concentration of the driver based on pixelated coloration detection technique using facial recognition. A portable camera will be placed at the front visor to capture facial expression and the eye activities. We evaluate DADS using 26 participants and have achieved 100% detection rate with good lighting condition and a low detection rate at night.

  3. Practical In-Depth Analysis of IDS Alerts for Tracing and Identifying Potential Attackers on Darknet

    Directory of Open Access Journals (Sweden)

    Jungsuk Song

    2017-02-01

    Full Text Available The darknet (i.e., a set of unused IP addresses is a very useful solution for observing the global trends of cyber threats and analyzing attack activities on the Internet. Since the darknet is not connected with real systems, in most cases, the incoming packets on the darknet (‘the darknet traffic’ do not contain a payload. This means that we are unable to get real malware from the darknet traffic. This situation makes it difficult for security experts (e.g., academic researchers, engineers, operators, etc. to identify whether the source hosts of the darknet traffic are infected by real malware or not. In this paper, we present the overall procedure of the in-depth analysis between the darknet traffic and IDS alerts using real data collected at the Science and Technology Cyber Security Center (S&T CSC in Korea and provide the detailed in-depth analysis results. The ultimate goal of this paper is to provide practical experience, insight and know-how to security experts so that they are able to identify and trace the root cause of the darknet traffic. The experimental results show that correlation analysis between the darknet traffic and IDS alerts is very useful to discover potential attack hosts, especially internal hosts, and to find out what kinds of malware infected them.

  4. Flood warnings in coastal areas: how do experience and information influence responses to alert services?

    Science.gov (United States)

    Pescaroli, G.; Magni, M.

    2015-04-01

    Many studies discuss the economic and technical aspects of flood warnings. Less attention has been given to the social and behavioural patterns that affect alert services. In particular, the literature focuses on warnings activated in river basins or marine environments without providing clear evidence on Mediterranean coastal areas, even though these are subjected to growing flood risk related to climate change. This paper is a first attempt to bridge this gap. Our research develops an in-depth analysis of the village of Cesenatico on the Adriatic Sea coast. Here the municipality adopted two complementary warning systems: a siren and an alert via short message service (SMS). The analysis focuses on a survey conducted in 2011 and 2012 with 228 participants. The relationships between social and behavioural variables and warning services are investigated as well as flood preparedness and information dissemination. Qualitative evidence from informal interviews is used to support the understanding of key responses. The conclusions show how different social and behavioural patterns can influence the effectiveness and use of warning systems, regardless of the technology adopted and the structural mitigation measures implemented. Education, training and accountability are seen to be critical elements for implementation. Finally, the statistical output is used to suggest new questions and new directions for research.

  5. Flood warnings in coastal areas: how do social and behavioural patterns influence alert services?

    Science.gov (United States)

    Pescaroli, G.; Magni, M.

    2015-01-01

    Many studies discuss the economic and technical aspects of flood warnings. Less attention has been given to the social and psychological patterns that affect alert services. In particular, the literature focuses on warnings activated in river basins or marine environments without providing clear evidence of relevance to Mediterranean coastal areas, even though these are subjected to growing flood risk related to climate change. This paper is a first attempt to bridge this gap. Our research develops an in- depth analysis of the village of Cesenatico on the Adriatic Sea coast. Here the municipality adopted two complementary warning systems: a siren and an alert via Short Message Service (SMS). The analysis focuses on a survey conducted in 2011 and 2012 with 228 participants. The relationships between social and behavioural variables and warning services are investigated, and so are flood preparedness and information dissemination. Qualitative evidence from informal interviews is used to support the understanding of key responses. The conclusions show how different social and behavioural patterns can influence the effectiveness and use of warning systems, regardless of the technology adopted and the structural mitigation measures implemented. Education, training and accountability are seen to be critical elements for improvement. Finally, the statistical output is used to suggest new questions and new directions for research.

  6. Red alert. The worldwide dangers of nuclear power

    Energy Technology Data Exchange (ETDEWEB)

    Cook, J

    1986-01-01

    The book 'Red Alert' considers the problems and hazards of nuclear power. The politics behind the nuclear power programmes in the United Kingdom and other countries are examined, along with the sequence of events in Britain which led to the building of the Magnox and Advanced Gas-Cooled nuclear reactors. Health hazards of radiation, radioactive waste management, nuclear weapons programmes, and radiation accidents including the Chernobyl accident, are also discussed. (U.K.).

  7. Conflict resolution and alert zone estimation in air traffic management

    Science.gov (United States)

    Kuo, Vincent Hao-Hung

    The current air traffic control (ATC) system provides separations among all aircraft through pre-defined routes and flight procedures, and active controller participation. In particular, en route separations are achieved by choices of different flight routes, different flight levels, and speed control. During the final descent approach over an extended terminal area, aircraft separations are achieved by speed changes, altitude changes, and path stretching. Recently, a concept of free flight has been proposed for future air traffic management. In the proposed free flight environment, aircraft operators can change flight paths in real time, in order to achieve the best efficiency for the aircraft. Air traffic controllers are only supposed to intervene when situation warrants, to resolve potential conflicts among aircraft. In both cases, there is a region around each aircraft called alert zone. As soon as another aircraft touches the alert zone of own aircraft, either the own aircraft or both aircraft must initiate avoidance maneuvers to resolve a potential conflict. This thesis develops a systematic approach based on nonlinear optimal control theories to estimate alert zones in two aircraft conflict scenarios. Specifically, point-mass aircraft models are used to describe aircraft motions. Separate uses of heading, speed, and altitude control are first examined, and then the synergetic use of two control authorities are studied. Both cooperative maneuvers (in which both aircraft act) and non-cooperative maneuvers (in which the own aircraft acts alone) are considered. Optimal control problems are formulated to minimize the initial relative separation between the two aircraft for all possible initial conditions, subject to the requirement that inter-aircraft separation at any time satisfies the separation requirement. These nonlinear optimal control problems are solved numerically using a collation approach and the NPSOL software line for nonlinear programming. In

  8. Alert-derivative bimodal space power and propulsion systems

    International Nuclear Information System (INIS)

    Houts, M.G.; Ranken, W.A.; Buksa, J.J.

    1994-01-01

    Safe, reliable, low-mass bimodal space power and propulsion systems could have numerous civilian and military applications. This paper discusses potential bimodal systems that could be derived from the ALERT space fission power supply concept. These bimodal concepts have the potential for providing 5 to 10 kW of electrical power and a total impulse of 100 MN-s at an average specific impulse of 770 s. System mass is on the order of 1000 kg

  9. Seismic Activity: Public Alert and Warning: Legal Implications

    Science.gov (United States)

    Zocchetti, D.

    2007-12-01

    As science and technology evolve in ways that increase our ability to inform the public of potentially destructive seismic activity, there are significant legal issues for consideration. Even though countries and even states within the United States have differing legal tenets that could either change or at least re-shape the outcome of specific legal questions that this session will be pondering, there are fundamental legal principals that will permeate. It is often said that the law lags behind society and in particular its technological developments. No doubt in the area of warning the public of impending destructive forces of nature or society, the law will need to do some catching up. The law is probably adequately developed for at least some preliminary discussion of the key issues. No matter the legal scheme, if there is a failure or perceived failure in the system to warn people of a pending emergencies, albeit an earthquake, tsunami, or other predictable event, those who are harmed or believe they are harmed will seek relief under the law. Every day there are situations wherein the failure to warn or to adequately warn is key, such as with faulty or defective consumer products, escaped prisoners, and police high-speed vehicle chases. With alert and warning systems for disaster, however, we have a unique set of facts. Generally, the systems and their failures occur during emergencies or at least during situations under apparently exigent circumstances when the disaster's predictability is widely recognized as less than 100 percent. The law, in particular United States tort law, has been particularly lenient when people and organizations are operating during compressed timeframes and their actions are generally considered necessary to address circumstances relative to public safety. The legal system has been forgiving when the actor that failed or appeared to fail was government. The courts have liberally applied the principal of sovereign immunity to

  10. The effects of Project ALERT one year past curriculum completion.

    Science.gov (United States)

    Ringwalt, Chris L; Clark, Heddy Kovach; Hanley, Sean; Shamblen, Stephen R; Flewelling, Robert L

    2010-06-01

    School-based drug prevention curricula constitute the nation's most prevalent strategy to prevent adolescent drug use. We evaluated the effects of one such curriculum, Project ALERT, on adolescent substance use. In particular, we sought to determine if a single effect on 30-day alcohol use, noted shortly following the completion of the 2-year program, could be detected 1 year later. We also looked for delayed effects on other outcomes of interest, namely lifetime alcohol use, and 30-day and lifetime use of cigarettes, marijuana, and inhalants. We employed a randomized controlled trial that used school as the unit of assignment. Thirty-four schools with grades 6-8 from 11 states completed the study. Seventy-one Project ALERT instructors taught 11 core lessons to sixth graders and 3 booster lessons to seventh graders. Students were assessed prior to the onset of the intervention, as sixth graders, after the completion of the 2-year curriculum, as seventh graders, and again 1 year later as eighth graders. This paper examines data from the pretest and final posttest. Using hierarchical nonlinear modeling, we found that our earlier effect on 30-day alcohol use did not persist. Further, we continued to find no effects for lifetime alcohol use and both the lifetime and 30-day use of cigarettes, marijuana, and inhalants. Our findings do not support the long-term effectiveness of Project ALERT, when delivered to sixth graders.

  11. AN AUTOMATED NETWORK SECURITYCHECKING AND ALERT SYSTEM: A NEW FRAMEWORK

    Directory of Open Access Journals (Sweden)

    Vivek Kumar Yadav

    2013-09-01

    Full Text Available Network security checking is a vital process to assess and to identify weaknesses in network for management of security. Insecure entry points of a network provide attackers an easy target to access and compromise. Open ports of network components such as firewalls, gateways and end systems are analogues to open gates of a building through which any one can get into. Network scanning is performed to identify insecure entry points in the network components. To find out vulnerabilities on these points vulnerability assessment is performed. So security checking consists of both activities- network scanning as well as vulnerability assessment. A single tool used for the security checking may not give reliable results. This paper presents a framework for assessing the security of a network using multiple Network Scanning and Vulnerability Assessment tools. The proposed framework is an extension of the framework given by Jun Yoon and Wontae Sim [1] which performs vulnerability scanning only. The framework presented here adds network scanning, alerting and reporting system to their framework. Network scanning and vulnerability tools together complement each other and make it amenable for centralized control and management. The reporting system of framework sends an email to the network administrator which contains detailed report (as attachment of security checking process. Alerting system sends a SMS message as an alert to the network administrator in case of severe threats found in the network. Initial results of the framework are encouraging and further work is in progress.

  12. Revealing the functional neuroanatomy of intrinsic alertness using fMRI: methodological peculiarities.

    Science.gov (United States)

    Clemens, Benjamin; Zvyagintsev, Mikhail; Sack, Alexander T; Sack, Alexander; Heinecke, Armin; Willmes, Klaus; Sturm, Walter

    2011-01-01

    Clinical observations and neuroimaging data revealed a right-hemisphere fronto-parietal-thalamic-brainstem network for intrinsic alertness, and additional left fronto-parietal activity during phasic alertness. The primary objective of this fMRI study was to map the functional neuroanatomy of intrinsic alertness as precisely as possible in healthy participants, using a novel assessment paradigm already employed in clinical settings. Both the paradigm and the experimental design were optimized to specifically assess intrinsic alertness, while at the same time controlling for sensory-motor processing. The present results suggest that the processing of intrinsic alertness is accompanied by increased activity within the brainstem, thalamus, anterior cingulate gyrus, right insula, and right parietal cortex. Additionally, we found increased activation in the left hemisphere around the middle frontal gyrus (BA 9), the insula, the supplementary motor area, and the cerebellum. Our results further suggest that rather minute aspects of the experimental design may induce aspects of phasic alertness, which in turn might lead to additional brain activation in left-frontal areas not normally involved in intrinsic alertness. Accordingly, left BA 9 activation may be related to co-activation of the phasic alertness network due to the switch between rest and task conditions functioning as an external warning cue triggering the phasic alertness network. Furthermore, activation of the intrinsic alertness network during fixation blocks due to enhanced expectancy shortly before the switch to the task block might, when subtracted from the task block, lead to diminished activation in the typical right hemisphere intrinsic alertness network. Thus, we cautiously suggest that--as a methodological artifact--left frontal activations might show up due to phasic alertness involvement and intrinsic alertness activations might be weakened due to contrasting with fixation blocks, when assessing the

  13. Time to Detection with BacT/Alert FA Plus Compared to BacT/Alert FA Blood Culture Media.

    Science.gov (United States)

    Nutman, A; Fisher Even-Tsur, S; Shapiro, G; Braun, T; Schwartz, D; Carmeli, Y

    2016-09-01

    Rapid identification of the causative pathogen in patients with bacteremia allows adjustment of antibiotic therapy and improves patient outcomes. We compared in vitro and real-life time to detection (TTD) of two blood culture media, BacT/Alert FA (FA) and BacT/Alert FA Plus (FA Plus), for the nine most common species of bacterial pathogens recovered from blood samples. Experimental data from simulated cultures was compared with microbiology records of TTD for both culture media with growth of the species of interest in clinical blood cultures. In the experimental conditions, median TTD was 3.8 hours (23.9 %) shorter using FA Plus media. The magnitude of reduction differed between species. Similarly, in real life data, FA Plus had shorter TTD than FA media; however, the difference between culture media was smaller, and median TTD was only 1 hour (8.5 %) less. We found shorter TTD with BacT/Alert FA Plus culture media, both experimentally and in real-life conditions and unrelated to antibiotic neutralization, highlighting the importance of appropriate blood culture media selection.

  14. Non-visual effects of light on melatonin, alertness and cognitive performance: can blue-enriched light keep us alert?

    Directory of Open Access Journals (Sweden)

    Sarah Laxhmi Chellappa

    Full Text Available BACKGROUND: Light exposure can cascade numerous effects on the human circadian process via the non-imaging forming system, whose spectral relevance is highest in the short-wavelength range. Here we investigated if commercially available compact fluorescent lamps with different colour temperatures can impact on alertness and cognitive performance. METHODS: Sixteen healthy young men were studied in a balanced cross-over design with light exposure of 3 different light settings (compact fluorescent lamps with light of 40 lux at 6500K and at 2500K and incandescent lamps of 40 lux at 3000K during 2 h in the evening. RESULTS: Exposure to light at 6500K induced greater melatonin suppression, together with enhanced subjective alertness, well-being and visual comfort. With respect to cognitive performance, light at 6500K led to significantly faster reaction times in tasks associated with sustained attention (Psychomotor Vigilance and GO/NOGO Task, but not in tasks associated with executive function (Paced Visual Serial Addition Task. This cognitive improvement was strongly related with attenuated salivary melatonin levels, particularly for the light condition at 6500K. CONCLUSIONS: Our findings suggest that the sensitivity of the human alerting and cognitive response to polychromatic light at levels as low as 40 lux, is blue-shifted relative to the three-cone visual photopic system. Thus, the selection of commercially available compact fluorescent lights with different colour temperatures significantly impacts on circadian physiology and cognitive performance at home and in the workplace.

  15. Workplace lighting for improving alertness and mood in daytime workers.

    Science.gov (United States)

    Pachito, Daniela V; Eckeli, Alan L; Desouky, Ahmed S; Corbett, Mark A; Partonen, Timo; Rajaratnam, Shantha Mw; Riera, Rachel

    2018-03-02

    Exposure to light plays a crucial role in biological processes, influencing mood and alertness. Daytime workers may be exposed to insufficient or inappropriate light during daytime, leading to mood disturbances and decreases in levels of alertness. To assess the effectiveness and safety of lighting interventions to improve alertness and mood in daytime workers. We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, seven other databases; ClinicalTrials.gov and the World Health Organization trials portal up to January 2018. We included randomised controlled trials (RCTs), and non-randomised controlled before-after trials (CBAs) that employed a cross-over or parallel-group design, focusing on any type of lighting interventions applied for daytime workers. Two review authors independently screened references in two stages, extracted outcome data and assessed risk of bias. We used standardised mean differences (SMDs) and 95% confidence intervals (CI) to pool data from different questionnaires and scales assessing the same outcome across different studies. We combined clinically homogeneous studies in a meta-analysis. We used the GRADE system to rate quality of evidence. The search yielded 2844 references. After screening titles and abstracts, we considered 34 full text articles for inclusion. We scrutinised reports against the eligibility criteria, resulting in the inclusion of five studies (three RCTs and two CBAs) with 282 participants altogether. These studies evaluated four types of comparisons: cool-white light, technically known as high correlated colour temperature (CCT) light versus standard illumination; different proportions of indirect and direct light; individually applied blue-enriched light versus no treatment; and individually applied morning bright light versus afternoon bright light for subsyndromal seasonal affective disorder.We found no studies comparing one level of illuminance versus another.We found two CBA

  16. Building a Communication, Education, an Outreach Program for the ShakeAlert National Earthquake Early Warning Program - Recommendations for Public Alerts Via Cell Phones

    Science.gov (United States)

    DeGroot, R. M.; Long, K.; Strauss, J. A.

    2017-12-01

    The United States Geological Survey (USGS) and its partners are developing the ShakeAlert Earthquake Early Warning System for the West Coast of the United States. To be an integral part of successful implementation, ShakeAlert engagement programs and materials must integrate with and leverage broader earthquake risk programs. New methods and products for dissemination must be multidisciplinary, cost effective, and consistent with existing hazards education and communication efforts. The ShakeAlert Joint Committee for Communication, Education, and Outreach (JCCEO), is identifying, developing, and cultivating partnerships with ShakeAlert stakeholders including Federal, State, academic partners, private companies, policy makers, and local organizations. Efforts include developing materials, methods for delivery, and reaching stakeholders with information on ShakeAlert, earthquake preparedness, and emergency protective actions. It is essential to develop standards to ensure information communicated via the alerts is consistent across the public and private sector and achieving a common understanding of what actions users take when they receive a ShakeAlert warning. In February 2017, the JCCEO convened the Warning Message Focus Group (WMFG) to provide findings and recommendations to the Alliance for Telecommunications Industry Solutions on the use of earthquake early warning message content standards for public alerts via cell phones. The WMFG represents communications, education, and outreach stakeholders from various sectors including ShakeAlert regional coordinators, industry, emergency managers, and subject matter experts from the social sciences. The group knowledge was combined with an in-depth literature review to ensure that all groups who could receive the message would be taken into account. The USGS and the participating states and agencies acknowledge that the implementation of ShakeAlert is a collective effort requiring the participation of hundreds of

  17. A Novel Design for Drug-Drug Interaction Alerts Improves Prescribing Efficiency.

    Science.gov (United States)

    Russ, Alissa L; Chen, Siying; Melton, Brittany L; Johnson, Elizabette G; Spina, Jeffrey R; Weiner, Michael; Zillich, Alan J

    2015-09-01

    Drug-drug interactions (DDIs) are common in clinical care and pose serious risks for patients. Electronic health records display DDI alerts that can influence prescribers, but the interface design of DDI alerts has largely been unstudied. In this study, the objective was to apply human factors engineering principles to alert design. It was hypothesized that redesigned DDI alerts would significantly improve prescribers' efficiency and reduce prescribing errors. In a counterbalanced, crossover study with prescribers, two DDI alert designs were evaluated. Department of Veterans Affairs (VA) prescribers were video recorded as they completed fictitious patient scenarios, which included DDI alerts of varying severity. Efficiency was measured from time-stamped recordings. Prescribing errors were evaluated against predefined criteria. Efficiency and prescribing errors were analyzed with the Wilcoxon signed-rank test. Other usability data were collected on the adequacy of alert content, prescribers' use of the DDI monograph, and alert navigation. Twenty prescribers completed patient scenarios for both designs. Prescribers resolved redesigned alerts in about half the time (redesign: 52 seconds versus original design: 97 seconds; p<.001). Prescribing errors were not significantly different between the two designs. Usability results indicate that DDI alerts might be enhanced by facilitating easier access to laboratory data and dosing information and by allowing prescribers to cancel either interacting medication directly from the alert. Results also suggest that neither design provided adequate information for decision making via the primary interface. Applying human factors principles to DDI alerts improved overall efficiency. Aspects of DDI alert design that could be further enhanced prior to implementation were also identified.

  18. Temperature distributions in pavement and bridge slabs heated by using vertical ground-source heat pump systems - doi: 10.4025/actascitechnol.v35i4.15712

    Directory of Open Access Journals (Sweden)

    Asım Balbay

    2013-10-01

    Full Text Available Temperature distribution which occurs in pavement and bridge slabs heated for de-icing and snow melting during cold periods is determined by using vertical ground-source heat pump (GSHP systems with U-tube ground heat exchanger (GHE. The bridge and pavement models (slabs for de-icing and snow melting were constructed. A three-dimensional finite element model (FEM was developed to simulate temperature distribution of bridge slab (BS and pavement slab (PS. The temperature distribution simulations of PS and BS were conducted numerically by computational fluid dynamics (CFD program named ‘Fluent’. Congruence between the simulations and experimental data was determined.   

  19. Sporotrichosis with Bone Involvement: An Alert to an Occupational Disease

    Directory of Open Access Journals (Sweden)

    Felipe de Carvalho Aguinaga

    2014-04-01

    Full Text Available Sporotrichosis is a subacute or chronic mycosis caused by a fungus of the genus Sporothrix, which is found in soil. It can be acquired by trauma to the skin. Bone and joint lesions are very rare. The city of Rio de Janeiro is undergoing an epidemic transmitted by cats, and this should be an alert for the risk to professionals in contact with these animals. The patient was a veterinarian who developed occupational sporotrichosis with osteoarticular involvement transmitted by a cat during a consultation.

  20. The Low-Level Wind Shear Alert System (LLWSAS)

    Science.gov (United States)

    1980-05-01

    ALERT SYSTEM (LLWSAS). (May R.. a.-ol - 8..’P" Imng Organization Report No, 9, Perfo~ring Or~ni-otlon Ro-r. -andAddress 10. Work Unit No. (TRAIS) Federal...rather than electronic approach. The 2-minute average adheres to recommended International Civil Aviation Organization (ICAO) standards (referernce 14...speed of 140 knots. **Cold front. 80 ’ # 90 0 STRONG CASES: COFF , 1975 80 9STRONG CASES: UNPU1BLISHED 70 60 A STRONG CASES: COFF , et al., 1978 50 \\ 50 -0

  1. Simulation and Proposed Handover Alert Algorithm for Mobile Communication System

    Directory of Open Access Journals (Sweden)

    Muzhir Shaban Al-Ani

    2009-10-01

    Full Text Available this paper deals with the simulation and presentation of a novel approach to design and implementation of algorithm to realize hand over process for a mobile communication system during mobile network. This algorithm performs the ability of the system to extract important information features about the received signal. When the strength of the received signal is dropped below a certain threshold value then an alert process is activated to achieve the continuity of the transmission due to a ready scan which is existed on time.

  2. Study on the possibility of assessment of alertness using subsidiary behaviors

    International Nuclear Information System (INIS)

    Hirose, Ayako; Nagasaka, Akihiko

    2003-01-01

    The aim of this study is to explore the possibility of assessment of alertness using subsidiary behaviors. Using the previous experimental data, 8 subjects' subsidiary behaviors, which appeared during 3 monotonous VDU tasks, were picked up by 3 experimenters. These behaviors were classified into 13 categories according to their similarity. As a physiological index, electroencephalogram (EEG), which was known as the most sensitive index for measuring alertness, was measured. To investigate whether the number of these behaviors could be utilized for assessment of alertness, the following studies were carried out: 1) the relationships among the task performance, categorized behaviors and EEG were analyzed to make sure whether alertness had an impact on the task performance and the behaviors, 2) using the task performance, the level of alertness was classified tentatively, then the behaviors that were changed by the classified level of alertness were specified, 3) to testify the possibility of assessment of alertness, discriminant analysis was conducted using the behaviors which were specified above, and 4) quantification analysis III and cross correlation analysis were carried out to explore if the behaviors could estimate a decline in alertness before the performance deteriorated. As the results of the above 4 points, the followings were suggested: 1) some subsidiary behaviors were influenced by alertness, to say nothing of performance, 2) regardless of individual differences, there were some behaviors that were changed by the level of alertness which was tentatively classified in this study, 3) the level of alertness at the point could assess using some behaviors, such as 'rub, pinch, and scratch', 'ease the stiffness', 'postural adjustments', 'movement of eye's and mouth', 'action of low alertness', and 4) some behaviors indicated the premonitory sign of a decline in alertness, the other increased when a decline in alertness had been observed. Also, depends on

  3. Investigating Driver Fatigue versus Alertness Using the Granger Causality Network

    Directory of Open Access Journals (Sweden)

    Wanzeng Kong

    2015-08-01

    Full Text Available Driving fatigue has been identified as one of the main factors affecting drivers’ safety. The aim of this study was to analyze drivers’ different mental states, such as alertness and drowsiness, and find out a neurometric indicator able to detect drivers’ fatigue level in terms of brain networks. Twelve young, healthy subjects were recruited to take part in a driver fatigue experiment under different simulated driving conditions. The Electroencephalogram (EEG signals of the subjects were recorded during the whole experiment and analyzed by using Granger-Causality-based brain effective networks. It was that the topology of the brain networks and the brain’s ability to integrate information changed when subjects shifted from the alert to the drowsy stage. In particular, there was a significant difference in terms of strength of Granger causality (GC in the frequency domain and the properties of the brain effective network i.e., causal flow, global efficiency and characteristic path length between such conditions. Also, some changes were more significant over the frontal brain lobes for the alpha frequency band. These findings might be used to detect drivers’ fatigue levels, and as reference work for future studies.

  4. Proposing alerts for pre and pro-haptens (QSAR2016) ...

    Science.gov (United States)

    Predictive testing to identify and characterise substances for their skin sensitisation potential has historically been based on animal tests such as the Local Lymph Node Assay (LLNA). In recent years, regulations in the cosmetics and chemicals sectors has provided a strong impetus to develop and evaluate non-animal alternative methods. The 3 test methods that have undergone extensive development and validation are the direct peptide reactivity assay (DPRA), the KeratinoSensTM and the human Cell Line Activation Test (h-CLAT). Whilst these methods have been shown to perform relatively well in predicting LLNA results (accuracy ~ 80%), a particular concern that has been raised is their ability to predict chemicals that need to be activated to act as sensitisers (either abiotically on the skin (pre-hapten) or metabolically in the skin (pro-hapten)). This study reviewed an EURL ECVAM dataset containing 271 substances for which information was available in the LLNA and for one or more of the three non-animal test methods. The chemical structures of the substances were inspected and each assigned to a reaction mechanistic domain. Fifty-three substances were expected to require activation. Plausible reaction pathways were considered for each of the substances from which three structural alerts were hypothesised: autoxidation to hydroperoxides, aromatic ortho and para-diamino or di phenol derivatives, and aromatic meta-diamino/hydroxy derivatives. For each alert, the av

  5. Towards cross-lingual alerting for bursty epidemic events.

    Science.gov (United States)

    Collier, Nigel

    2011-10-06

    Online news reports are increasingly becoming a source for event-based early warning systems that detect natural disasters. Harnessing the massive volume of information available from multilingual newswire presents as many challanges as opportunities due to the patterns of reporting complex spatio-temporal events. In this article we study the problem of utilising correlated event reports across languages. We track the evolution of 16 disease outbreaks using 5 temporal aberration detection algorithms on text-mined events classified according to disease and outbreak country. Using ProMED reports as a silver standard, comparative analysis of news data for 13 languages over a 129 day trial period showed improved sensitivity, F1 and timeliness across most models using cross-lingual events. We report a detailed case study analysis for Cholera in Angola 2010 which highlights the challenges faced in correlating news events with the silver standard. The results show that automated health surveillance using multilingual text mining has the potential to turn low value news into high value alerts if informed choices are used to govern the selection of models and data sources. An implementation of the C2 alerting algorithm using multilingual news is available at the BioCaster portal http://born.nii.ac.jp/?page=globalroundup.

  6. Towards cross-lingual alerting for bursty epidemic events

    Directory of Open Access Journals (Sweden)

    Collier Nigel

    2011-10-01

    Full Text Available Abstract Background Online news reports are increasingly becoming a source for event-based early warning systems that detect natural disasters. Harnessing the massive volume of information available from multilingual newswire presents as many challanges as opportunities due to the patterns of reporting complex spatio-temporal events. Results In this article we study the problem of utilising correlated event reports across languages. We track the evolution of 16 disease outbreaks using 5 temporal aberration detection algorithms on text-mined events classified according to disease and outbreak country. Using ProMED reports as a silver standard, comparative analysis of news data for 13 languages over a 129 day trial period showed improved sensitivity, F1 and timeliness across most models using cross-lingual events. We report a detailed case study analysis for Cholera in Angola 2010 which highlights the challenges faced in correlating news events with the silver standard. Conclusions The results show that automated health surveillance using multilingual text mining has the potential to turn low value news into high value alerts if informed choices are used to govern the selection of models and data sources. An implementation of the C2 alerting algorithm using multilingual news is available at the BioCaster portal http://born.nii.ac.jp/?page=globalroundup.

  7. Universal Safety Distance Alert Device for Road Vehicles

    Directory of Open Access Journals (Sweden)

    Matic Virant

    2016-04-01

    Full Text Available Driving with too short of a safety distance is a common problem in road traffic, often with traffic accidents as a consequence. Research has identified a lack of vehicle-mountable devices for alerting the drivers of trailing vehicles about keeping a sufficient safe distance. The principal requirements for such a device were defined. A conceptual study was performed in order to select the components for the integration of the device. Based on the results of this study, a working prototype of a flexible, self-contained device was designed, built and tested. The device is intended to be mounted on the rear of a vehicle. It uses radar as the primary distance sensor, assisted with a GPS receiver for velocity measurement. A Raspberry Pi single-board computer is used for data acquisition and processing. The alerts are shown on an LED-matrix display mounted on the rear of the host vehicle. The device software is written in Python and provides automatic operation without requiring any user intervention. The tests have shown that the device is usable on almost any motor vehicle and performs reliably in simulated and real traffic. The open issues and possibilities for future improvements are presented in the Discussion.

  8. Relationship between alertness, performance, and body temperature in humans

    Science.gov (United States)

    Wright, Kenneth P Jr; Hull, Joseph T.; Czeisler, Charles A.

    2002-01-01

    Body temperature has been reported to influence human performance. Performance is reported to be better when body temperature is high/near its circadian peak and worse when body temperature is low/near its circadian minimum. We assessed whether this relationship between performance and body temperature reflects the regulation of both the internal biological timekeeping system and/or the influence of body temperature on performance independent of circadian phase. Fourteen subjects participated in a forced desynchrony protocol allowing assessment of the relationship between body temperature and performance while controlling for circadian phase and hours awake. Most neurobehavioral measures varied as a function of internal biological time and duration of wakefulness. A number of performance measures were better when body temperature was elevated, including working memory, subjective alertness, visual attention, and the slowest 10% of reaction times. These findings demonstrate that an increased body temperature, associated with and independent of internal biological time, is correlated with improved performance and alertness. These results support the hypothesis that body temperature modulates neurobehavioral function in humans.

  9. Regulatory alerts for dietary supplements in Canada and the United States, 2005-13.

    Science.gov (United States)

    Abe, Andrew M; Hein, Darren J; Gregory, Philip J

    2015-06-01

    Dietary supplement regulatory alerts published by the Food and Drug Administration (FDA) and Health Canada were evaluated and characterized. FDA MedWatch and Health Canada websites were reviewed to identify regulatory alerts regarding dietary supplements from January 1, 2005, through December 31, 2013. Alerts were analyzed to identify product characteristics that may be predictive of product quality issues and potential patient harm. A total of 1560 dietary supplement-related regulatory alerts were identified. Of those, 1287 (83%) were identified through Health Canada, and 273 (18%) were identified through FDA MedWatch. The country of origin of dietary supplements associated with regulatory alerts was not provided in most regulatory alerts; however, when their origin was provided, the United States was the most common. Dietary supplements intended for sexual enhancement were the subject of 33% of all regulatory alerts identified. Products purchased online were the most likely to be associated with a regulatory alert. Dietary supplements intended for sexual enhancement, weight loss, and bodybuilding or athletic performance appeared to pose the greatest risk for patient harm due to product contamination with a pharmaceutical such as a phosphodiesterase-5 inhibitor or sibutramine. Analysis of Canadian and U.S. regulatory alerts concerning dietary supplements revealed that more than 80% of the composite alerts were issued by Health Canada. The most common intended uses of supplements for which alerts were issued were sexual enhancement, weight loss, and bodybuilding or athletic performance. The most common reason for alerts was the presence of a pharmaceutical contaminant. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  10. Theoretical analysis and experimental study to solar assisted ground-source heat pump system%太阳能辅助系统的理论分析和实验研究

    Institute of Scientific and Technical Information of China (English)

    杨鹏; 刘自强; 侯静

    2011-01-01

    As a clean, renewable energy, the geothermal energy and solar energy are trend of develo- ping and using new energies in the future. This paper introduces solar assisted Ground Source Heat Pump system, combined with the advantage of t the geothermal energy and solar energy. Through theoretical analysis and experiment, the solar assisted Ground Source Heat Pump system is proved to be feasible and scientific.%地热能和太阳能作为清洁、可再生的能源,是未来开发和利用新能源的趋势,本文介绍了太阳能辅助地源热泵系统,是将二者结合,取长补短的一种热泵形式。通过理论分析和实验验证。证明了太阳能辅助地源热泵系统的可行性和科学性。

  11. Changes in decibel scale wavelength properties of EEG with alertness levels while performing sustained attention tasks.

    Science.gov (United States)

    Arjunan, Sridhar P; Kumar, Dinesh K; Jung, Tzyy-Ping

    2009-01-01

    Loss of alertness can have dire consequences for people controlling motorized equipment or for people in professions such as defense. Electroencephalogram (EEG) is known to be related to alertness of the person, but due to high level of noise and low signal strength, the use of EEG for such applications has been considered to be unreliable. This study reports the fractal analysis of EEG and identifies the use of maximum fractal length (MFL) as a feature that is inversely correlated with the alertness of the subject. The results show that MFL (of only single channel of EEG) indicates the loss of alertness of the individual with mean (inverse) correlation coefficient = 0.82.

  12. A randomised clinical trial of intrapartum fetal monitoring with computer analysis and alerts versus previously available monitoring

    Directory of Open Access Journals (Sweden)

    Santos Cristina

    2010-10-01

    Full Text Available Abstract Background Intrapartum fetal hypoxia remains an important cause of death and permanent handicap and in a significant proportion of cases there is evidence of suboptimal care related to fetal surveillance. Cardiotocographic (CTG monitoring remains the basis of intrapartum surveillance, but its interpretation by healthcare professionals lacks reproducibility and the technology has not been shown to improve clinically important outcomes. The addition of fetal electrocardiogram analysis has increased the potential to avoid adverse outcomes, but CTG interpretation remains its main weakness. A program for computerised analysis of intrapartum fetal signals, incorporating real-time alerts for healthcare professionals, has recently been developed. There is a need to determine whether this technology can result in better perinatal outcomes. Methods/design This is a multicentre randomised clinical trial. Inclusion criteria are: women aged ≥ 16 years, able to provide written informed consent, singleton pregnancies ≥ 36 weeks, cephalic presentation, no known major fetal malformations, in labour but excluding active second stage, planned for continuous CTG monitoring, and no known contra-indication for vaginal delivery. Eligible women will be randomised using a computer-generated randomisation sequence to one of the two arms: continuous computer analysis of fetal monitoring signals with real-time alerts (intervention arm or continuous CTG monitoring as previously performed (control arm. Electrocardiographic monitoring and fetal scalp blood sampling will be available in both arms. The primary outcome measure is the incidence of fetal metabolic acidosis (umbilical artery pH ecf > 12 mmol/L. Secondary outcome measures are: caesarean section and instrumental vaginal delivery rates, use of fetal blood sampling, 5-minute Apgar score Discussion This study will provide evidence of the impact of intrapartum monitoring with computer analysis and real

  13. Life Cycle Assessment of Residential Heating and Cooling Systems in Minnesota A comprehensive analysis on life cycle greenhouse gas (GHG) emissions and cost-effectiveness of ground source heat pump (GSHP) systems compared to the conventional gas furnace and air conditioner system

    Science.gov (United States)

    Li, Mo

    Ground Source Heat Pump (GSHP) technologies for residential heating and cooling are often suggested as an effective means to curb energy consumption, reduce greenhouse gas (GHG) emissions and lower homeowners' heating and cooling costs. As such, numerous federal, state and utility-based incentives, most often in the forms of financial incentives, installation rebates, and loan programs, have been made available for these technologies. While GSHP technology for space heating and cooling is well understood, with widespread implementation across the U.S., research specific to the environmental and economic performance of these systems in cold climates, such as Minnesota, is limited. In this study, a comparative environmental life cycle assessment (LCA) is conducted of typical residential HVAC (Heating, Ventilation, and Air Conditioning) systems in Minnesota to investigate greenhouse gas (GHG) emissions for delivering 20 years of residential heating and cooling—maintaining indoor temperatures of 68°F (20°C) and 75°F (24°C) in Minnesota-specific heating and cooling seasons, respectively. Eight residential GSHP design scenarios (i.e. horizontal loop field, vertical loop field, high coefficient of performance, low coefficient of performance, hybrid natural gas heat back-up) and one conventional natural gas furnace and air conditioner system are assessed for GHG and life cycle economic costs. Life cycle GHG emissions were found to range between 1.09 × 105 kg CO2 eq. and 1.86 × 10 5 kg CO2 eq. Six of the eight GSHP technology scenarios had fewer carbon impacts than the conventional system. Only in cases of horizontal low-efficiency GSHP and hybrid, do results suggest increased GHGs. Life cycle costs and present value analyses suggest GSHP technologies can be cost competitive over their 20-year life, but that policy incentives may be required to reduce the high up-front capital costs of GSHPs and relatively long payback periods of more than 20 years. In addition

  14. Professional responsibility and patient retention: alerts for the new dentist.

    Science.gov (United States)

    Maitland, Ronald

    2014-01-01

    Getting to know your patients, well beyond recognition of their specific chief dental complaint, is most important in operating a successful and satisfying practice. In addition to the clinical findings and pertinent history alerts, a good understanding of the person being treated can go a long way toward cementing lasting and rewarding doctor-patient relationships. Almost all new patients to the practice are welcome. However, an occasional "difficult" patient can be identified. This is the patient who you will not be able to satisfy, who cultivates misunderstandings, is unfairly over demanding, wastes office time in innumerable ways and eventually causes great frustration for the dentist. These patients may leave the practice in an unpleasant termination. Concerns of litigation arise, and one must also consider the waste of economic and emotional currency, as well as any other negative repercussions that may result. The dentist should become skilled at early identification of potentially risky, disruptive and problematic persons seeking treatment.

  15. Automated detection of structural alerts (chemical fragments in (ecotoxicology

    Directory of Open Access Journals (Sweden)

    Ronan Bureau

    2013-02-01

    Full Text Available This mini-review describes the evolution of different algorithms dedicated to the automated discovery of chemical fragments associated to (ecotoxicological endpoints. These structural alerts correspond to one of the most interesting approach of in silico toxicology due to their direct link with specific toxicological mechanisms. A number of expert systems are already available but, since the first work in this field which considered a binomial distribution of chemical fragments between two datasets, new data miners were developed and applied with success in chemoinformatics. The frequency of a chemical fragment in a dataset is often at the core of the process for the definition of its toxicological relevance. However, recent progresses in data mining provide new insights into the automated discovery of new rules. Particularly, this review highlights the notion of Emerging Patterns that can capture contrasts between classes of data.

  16. AUTOMATED DETECTION OF STRUCTURAL ALERTS (CHEMICAL FRAGMENTS IN (ECOTOXICOLOGY

    Directory of Open Access Journals (Sweden)

    Alban Lepailleur

    2013-02-01

    Full Text Available This mini-review describes the evolution of different algorithms dedicated to the automated discovery of chemical fragments associated to (ecotoxicological endpoints. These structural alerts correspond to one of the most interesting approach of in silico toxicology due to their direct link with specific toxicological mechanisms. A number of expert systems are already available but, since the first work in this field which considered a binomial distribution of chemical fragments between two datasets, new data miners were developed and applied with success in chemoinformatics. The frequency of a chemical fragment in a dataset is often at the core of the process for the definition of its toxicological relevance. However, recent progresses in data mining provide new insights into the automated discovery of new rules. Particularly, this review highlights the notion of Emerging Patterns that can capture contrasts between classes of data.

  17. FULCRUM - A dam safety management and alert system

    Energy Technology Data Exchange (ETDEWEB)

    Butt, Cameron; Greenaway, Graham [Knight Piesold Ltd., Vancouver, (Canada)

    2010-07-01

    Efficient management of instrumentation, monitoring and inspection data are the keys to safe performance and dam structure stability. This paper presented a data management system, FULCRUM, developed for dam safety management. FULCRUM is a secure web-based data management system which simplifies the process of data collection, processing and analysis of the information. The system was designed to organize and coordinate dam safety management requirements. Geotechnical instrumentation such as piezometers or inclinometers and operating data can be added to the database. Data from routine surveillance and engineering inspection can also be incorporated into the database. The system provides users with immediate access to historical and recent data. The integration of a GIS system allows for rapid assessment of the project site. Customisable alerting protocols can be set to identify and respond quickly to significant changes in operating conditions and potential impacts on dam safety.

  18. Technology.

    Science.gov (United States)

    Online-Offline, 1998

    1998-01-01

    Focuses on technology, on advances in such areas as aeronautics, electronics, physics, the space sciences, as well as computers and the attendant progress in medicine, robotics, and artificial intelligence. Describes educational resources for elementary and middle school students, including Web sites, CD-ROMs and software, videotapes, books,…

  19. Turning Off Frequently Overridden Drug Alerts: Limited Opportunities for Doing It Safely

    NARCIS (Netherlands)

    I.H. van der Sijs (Heleen); J.E.C.M. Aarts (Jos); T. van Gelder (Teun); M. Berg (Marc); A.G. Vulto (Arnold)

    2008-01-01

    textabstractObjectives: This study sought to identify opportunities to safely turn off frequently overridden drug-drug interaction alerts (DDIs) in computerized physician order entry (CPOE). Design: Quantitative retrospective analysis of drug safety alerts overridden during 1 month and qualitative

  20. Cooperative Monitoring Center Occasional Paper/9: De-Alerting Strategic Ballistic Missiles

    Energy Technology Data Exchange (ETDEWEB)

    Connell, Leonard W.; Edenburn, Michael W.; Fraley, Stanley K.; Trost, Lawrence C.

    1999-03-01

    This paper presents a framework for evaluating the technical merits of strategic ballistic missile de-alerting measures, and it uses the framework to evaluate a variety of possible measures for silo-based, land-mobile, and submarine-based missiles. De-alerting measures are defined for the purpose of this paper as reversible actions taken to increase the time or effort required to launch a strategic ballistic missile. The paper does not assess the desirability of pursuing a de-alerting program. Such an assessment is highly context dependent. The paper postulates that if de-alerting is desirable and is used as an arms control mechanism, de-alerting measures should satisfy specific cirteria relating to force security, practicality, effectiveness, significant delay, and verifiability. Silo-launched missiles lend themselves most readily to de-alerting verification, because communications necessary for monitoring do not increase the vulnerabilty of the weapons by a significant amount. Land-mobile missile de-alerting measures would be more challenging to verify, because monitoring measures that disclose the launcher's location would potentially increase their vulnerability. Submarine-launched missile de-alerting measures would be extremely challlenging if not impossible to monitor without increasing the submarine's vulnerability.

  1. The Influence of Alertness on Spatial and Nonspatial Components of Visual Attention

    Science.gov (United States)

    Matthias, Ellen; Bublak, Peter; Muller, Hermann J.; Schneider, Werner X.; Krummenacher, Joseph; Finke, Kathrin

    2010-01-01

    Three experiments investigated whether spatial and nonspatial components of visual attention would be influenced by changes in (healthy, young) subjects' level of alertness and whether such effects on separable components would occur independently of each other. The experiments used a no-cue/alerting-cue design with varying cue-target stimulus…

  2. 75 FR 26196 - Publication of OIG Updated Special Fraud Alert on Telemarketing by Durable Medical Equipment...

    Science.gov (United States)

    2010-05-11

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Office of Inspector General Publication of OIG Updated Special Fraud Alert on Telemarketing by Durable Medical Equipment Suppliers AGENCY: Office of Inspector...) 205-0007. SUPPLEMENTARY INFORMATION: In our publication of the OIG Updated Special Fraud Alert on...

  3. Winter Weather Tips: Understanding Alerts and Staying Safe this Season | Poster

    Science.gov (United States)

    By Jenna Seiss and Kylie Tomlin, Guest Writers, and Ashley DeVine, Staff Writer Maryland residents face the possibility of dangerous winter weather each year—from icy conditions to frigid temperatures. You may be familiar with the different types of winter weather alerts issued by the National Weather Service (NWS), but do you know what each alert means?  

  4. Unintended consequences of reducing QT-alert overload in a computerized physician order entry system

    NARCIS (Netherlands)

    I.H. van der Sijs (Heleen); R. Kowlesar (Ravi); J.E.C.M. Aarts (Jos); M. Berg (Marc); A.G. Vulto (Arnold); T. van Gelder (Teun)

    2009-01-01

    textabstractPurpose: After complaints of too many low-specificity drug-drug interaction (DDI) alerts on QT prolongation, the rules for QT alerting in the Dutch national drug database were restricted in 2007 to obviously QT-prolonging drugs. The aim of this virtual study was to investigate whether

  5. Investigating Visual Alerting in the Maritime Domain; Report on 3 Experiments, With Supporting Documentation

    Science.gov (United States)

    2010-04-01

    opérateurs les états ou événements critiques qui requièrent leur attention. La recherche dont il est question ici vise principalement à alerter...Visual alerting in complex command and control environments. Poster presented at the Human Factors and Ergonomics Society 53rd Annual Meeting, San

  6. 14 CFR 121.360 - Ground proximity warning-glide slope deviation alerting system.

    Science.gov (United States)

    2010-01-01

    ... deviation alerting system. 121.360 Section 121.360 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... Equipment Requirements § 121.360 Ground proximity warning-glide slope deviation alerting system. (a) No... system that meets the performance and environmental standards of TSO-C92 (available from the FAA, 800...

  7. 76 FR 28789 - Draft Alert Entitled “Preventing Occupational Respiratory Disease From Dampness in Office...

    Science.gov (United States)

    2011-05-18

    ... NIOSH-238] Draft Alert Entitled ``Preventing Occupational Respiratory Disease From Dampness in Office... Institute for Occupational Safety and Health (NIOSH) of the Centers for Disease Control and Prevention (CDC), announces the availability of a draft Alert entitled ``Preventing Occupational Respiratory Disease from...

  8. Impaired Conflict Resolution and Alerting in Children with ADHD: Evidence from the Attention Network Task (ANT)

    Science.gov (United States)

    Johnson, Katherine A.; Robertson, Ian H.; Barry, Edwina; Mulligan, Aisling; Daibhis, Aoife; Daly, Michael; Watchorn, Amy; Gill, Michael; Bellgrove, Mark A.

    2008-01-01

    Background: An important theory of attention suggests that there are three separate networks that execute discrete cognitive functions. The "alerting" network acquires and maintains an alert state, the "orienting" network selects information from sensory input and the "conflict" network resolves conflict that arises between potential responses.…

  9. School-Based Drug Prevention among At-Risk Adolescents: Effects of ALERT Plus

    Science.gov (United States)

    Longshore, Douglas; Ellickson, Phyllis L.; McCaffrey, Daniel F.; St. Clair, Patricia A.

    2007-01-01

    In a recent randomized field trial, Ellickson et al. found the Project ALERT drug prevention curriculum curbed alcohol misuse and tobacco and marijuana use among eighth-grade adolescents. This article reports effects among ninth-grade at-risk adolescents. Comparisons between at-risk girls in ALERT Plus schools (basic curriculum extended to ninth…

  10. Simplify the interpretation of alert lists for clinical mastitis in automatic

    NARCIS (Netherlands)

    Steeneveld, W.; Gaag, van der M.A.; Barkema, H.W.; Hogeveen, H.

    2010-01-01

    Based on sensor measurements, an automatic milking system (AMS) generates mastitis alert lists indicating cows which are likely to have clinical mastitis (CM). Because of the general assumption of equal probabilities of developing CM for all cows, all alerts on the list have the same success rate.

  11. 太阳能——地源热泵耦合系统在某办公楼中的应用%Application of solar energy ground source heat pump coupling system in an office building

    Institute of Scientific and Technical Information of China (English)

    陈杰; 贾瑞远

    2017-01-01

    the winter heating by using solar energy,ground source heat pump coupling system,both energy conservation and environmental protection and can further improve the utilization rate of energy and no pollution to the environment.The office building in 50000m2 as an example to analyze the energy saving of the system,environmental protection and economy.%利用太阳能一一地源热泵耦合系统进行冬季供暖,既节能环保又能进一步提高能源的利用率且对环境无污染.本文以50000m2的办公建筑为例分析了该系统的节能、环保及经济性.

  12. PATIENT AND PUBLIC INVOLVEMENT IN EARLY AWARENESS AND ALERT ACTIVITIES: AN EXAMPLE FROM THE UNITED KINGDOM.

    Science.gov (United States)

    Simpson, Sue; Cook, Alison; Miles, Kathryn

    2018-01-01

    The aim of this study is to report on the experiences, benefits, and challenges of patient and public involvement and engagement (PPIE) from a publicly funded early awareness and alert (EAA) system in the United Kingdom. Using email, telephone, a Web site portal, Twitter and focus groups, patients and the public were involved and engaged in the recognized stages of an EAA system: identification, filtration, prioritization, early assessment, and dissemination. Approaches for PPIE were successfully integrated into all aspects of the National Institute for Health Research Horizon Scanning Research and Intelligence Centre's EAA system. Input into identification activities was not as beneficial as involvement in prioritization and early assessment. Patients gave useful insight into the Centre's Web site and engaging patients using Twitter has enabled the Centre to disseminate outputs to a wider audience. EAA systems should consider involving and engaging with patients and the public in identification, prioritization, and assessment of emerging health technologies where practicable. Further research is required to examine the value and impact of PPIE in EAA activities and in the early development of health technologies.

  13. Solar-assisted ground-source heat pump system design and case study%太阳能辅助地埋管地源热泵系统设计及实例分析

    Institute of Scientific and Technical Information of China (English)

    季永明; 端木琳; 李祥立

    2017-01-01

    Presents an improved method to determine the solar collector area of the solar-assisted ground-source heat pump system based on the heat balance method.For a commercial building in Dalian,proposes the design scheme of a solar-assisted ground-source heat pump system.Simulates the operating parameters of the system by TRNSYS,and the results show that,on the basis of ensuring the heating capacity of the building,the system guarantees the average temperature of the thermal storage soil which contains the ground heat exchanger periodic and consistent change,and the COP of the heat pump is improved significantly compared with that of the system without solar collectors in winter.%基于热平衡法提出了确定太阳能辅助地埋管地源热泵系统中太阳能集热器面积的方法.针对大连地区一公共建筑,提出了太阳能辅助地埋管地源热泵系统设计方案.采用TRNSYS软件对该系统运行参数进行了仿真模拟,结果显示,在保证建筑供热量的基础上,系统能长期保证热泵源侧换热器所在蓄热土壤平均温度呈周期性一致变化,且冬季热泵机组COP较无集热器工况显著提高.

  14. Test and Analysis of Solar Energy-ground Source Heat Pump Complex Systems%太阳能-地源热泵复合系统的实验研究

    Institute of Scientific and Technical Information of China (English)

    侯静; 荆有印; 王静; 杨鹏

    2012-01-01

    The ground-source heat pump, a trend in the future, is a high efficiency system that uses the renewable geothermal. But in northern China, the heat load is the major way. In this, the heat that underground pipe absorbs in winter is more than the heat discharged by underground pipe in summer. After long-time running, the heat pump system will destroy the soil temperature field. This article describes a complex heat pump system of solar-ground source. And this article, through experiment, will prove that the solar assisted system can effectively restore soil temperature increase the coefficient of performance and achieve long-term stable operation of heat pump system.%地源热泵是利用可再生能源地热能的一种高效热泵系统,是未来发展的趋势。但在我国北方地区,大部分以热负荷为主,冬季地下埋管的取热量高于夏季的释热量,长期运行会破坏土壤温度场。介绍了太阳能一地源热泵复合系统,通过实验验证了太阳能辅助系统能够有效恢复土壤温度,提高系统性能系数,可以实现热泵长期稳定的运行。

  15. Alertness Modulates Conflict Adaptation and Feature Integration in an Opposite Way

    Science.gov (United States)

    Chen, Jia; Huang, Xiting; Chen, Antao

    2013-01-01

    Previous studies show that the congruency sequence effect can result from both the conflict adaptation effect (CAE) and feature integration effect which can be observed as the repetition priming effect (RPE) and feature overlap effect (FOE) depending on different experimental conditions. Evidence from neuroimaging studies suggests that a close correlation exists between the neural mechanisms of alertness-related modulations and the congruency sequence effect. However, little is known about whether and how alertness mediates the congruency sequence effect. In Experiment 1, the Attentional Networks Test (ANT) and a modified flanker task were used to evaluate whether the alertness of the attentional functions had a correlation with the CAE and RPE. In Experimental 2, the ANT and another modified flanker task were used to investigate whether alertness of the attentional functions correlate with the CAE and FOE. In Experiment 1, through the correlative analysis, we found a significant positive correlation between alertness and the CAE, and a negative correlation between the alertness and the RPE. Moreover, a significant negative correlation existed between CAE and RPE. In Experiment 2, we found a marginally significant negative correlation between the CAE and the RPE, but the correlation between alertness and FOE, CAE and FOE was not significant. These results suggest that alertness can modulate conflict adaptation and feature integration in an opposite way. Participants at the high alerting level group may tend to use the top-down cognitive processing strategy, whereas participants at the low alerting level group tend to use the bottom-up processing strategy. PMID:24250824

  16. Alertness modulates conflict adaptation and feature integration in an opposite way.

    Directory of Open Access Journals (Sweden)

    Peiduo Liu

    Full Text Available Previous studies show that the congruency sequence effect can result from both the conflict adaptation effect (CAE and feature integration effect which can be observed as the repetition priming effect (RPE and feature overlap effect (FOE depending on different experimental conditions. Evidence from neuroimaging studies suggests that a close correlation exists between the neural mechanisms of alertness-related modulations and the congruency sequence effect. However, little is known about whether and how alertness mediates the congruency sequence effect. In Experiment 1, the Attentional Networks Test (ANT and a modified flanker task were used to evaluate whether the alertness of the attentional functions had a correlation with the CAE and RPE. In Experimental 2, the ANT and another modified flanker task were used to investigate whether alertness of the attentional functions correlate with the CAE and FOE. In Experiment 1, through the correlative analysis, we found a significant positive correlation between alertness and the CAE, and a negative correlation between the alertness and the RPE. Moreover, a significant negative correlation existed between CAE and RPE. In Experiment 2, we found a marginally significant negative correlation between the CAE and the RPE, but the correlation between alertness and FOE, CAE and FOE was not significant. These results suggest that alertness can modulate conflict adaptation and feature integration in an opposite way. Participants at the high alerting level group may tend to use the top-down cognitive processing strategy, whereas participants at the low alerting level group tend to use the bottom-up processing strategy.

  17. Adoption of medication alert systems in hospital outpatient departments in Taiwan.

    Science.gov (United States)

    Kuo, Yu-Chun; Cheng, Shou-Hsia

    2017-06-01

    The adoption of medication alert systems in the health care sector varies among regions. In Taiwan, the health authority introduced policies in 2005 to encourage the adoption of medication alert systems in hospitals. This study aimed to understand the adoption of medication alert systems in the outpatient departments of hospitals in Taiwan using a nationwide survey. A questionnaire was developed and mailed to 380 accredited general hospitals in Taiwan in 2013. The information collected from the questionnaire concerning the outpatient department included (1) the time of adoption of a medication alert system; (2) the operation of individual alert functions: availability, management, and stability; and (3) hospital characteristics: accreditation level, teaching status, ownership, and number of beds. A total of 216 hospitals completed and returned the questionnaire, corresponding to a response rate of 56.8%. The adoption rate of medication alert systems in hospital outpatient departments increased from less than 10% in 1997-95.83% in 2012. Approximately two-thirds of the hospitals developed and maintained the alert systems independently or collaboratively with vendors. Teaching and large hospitals tended to develop more advanced alert functions such as drug-drug interaction functions. Improving the safety and quality of pharmaceutical services and meeting the policy requirements are reasons for hospitals to establish medication alert systems. The adoption rate of medication alert systems reached 95% in accredited general hospitals in Taiwan. Government policy and available health information professionals and vendors may somewhat contribute to the high adoption rate. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Effectiveness of National Weather Service heat alerts in preventing mortality in 20 US cities.

    Science.gov (United States)

    Weinberger, Kate R; Zanobetti, Antonella; Schwartz, Joel; Wellenius, Gregory A

    2018-04-09

    Extreme heat is a well-documented public health threat. The US National Weather Service (NWS) issues heat advisories and warnings (collectively, "heat alerts") in advance of forecast extreme heat events. The effectiveness of these alerts in preventing deaths remains largely unknown. To quantify the change in mortality rates associated with heat alerts in 20 US cities between 2001 and 2006. Because NWS heat alerts are issued based on forecast weather and these forecasts are imperfect, in any given location there exists a set of days of similar observed heat index in which heat alerts have been issued for some days but not others. We used a case-crossover design and conditional logistic regression to compare mortality rates on days with versus without heat alerts among such eligible days, adjusting for maximum daily heat index and temporal factors. We combined city-specific estimates into a summary measure using standard random-effects meta-analytic techniques. Overall, NWS heat alerts were not associated with lower mortality rates (percent change in rate: -0.5% [95% CI: -2.8, 1.9]). In Philadelphia, heat alerts were associated with a 4.4% (95% CI: -8.3, -0.3) lower mortality rate or an estimated 45.1 (95% empirical CI: 3.1, 84.1) deaths averted per year if this association is assumed to be causal. No statistically significant beneficial association was observed in other individual cities. Our results suggest that between 2001 and 2006, NWS heat alerts were not associated with lower mortality in most cities studied, potentially missing a valuable opportunity to avert a substantial number of heat-related deaths. These results highlight the need to better link alerts to effective communication and intervention strategies to reduce heat-related mortality. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Technology

    Directory of Open Access Journals (Sweden)

    Xu Jing

    2016-01-01

    Full Text Available The traditional answer card reading method using OMR (Optical Mark Reader, most commonly, OMR special card special use, less versatile, high cost, aiming at the existing problems proposed a method based on pattern recognition of the answer card identification method. Using the method based on Line Segment Detector to detect the tilt of the image, the existence of tilt image rotation correction, and eventually achieve positioning and detection of answers to the answer sheet .Pattern recognition technology for automatic reading, high accuracy, detect faster

  20. A novel strategy for evaluating the effects of an electronic test ordering alert message: Optimizing cardiac marker use.

    Science.gov (United States)

    Baron, Jason M; Lewandrowski, Kent B; Kamis, Irina K; Singh, Balaji; Belkziz, Sidi M; Dighe, Anand S

    2012-01-01

    Laboratory ordering functions within computerized provider order entry (CPOE) systems typically support the display of electronic alert messages to improve test utilization or implement new ordering policies. However, alert strategies have been shown to vary considerably in their success and the characteristics contributing to an alert's success are poorly understood. Improved methodologies are needed to evaluate alerts and their mechanisms of action. Clinicians order inpatient and emergency department laboratory tests using our institutional CPOE system. We analyzed user interaction data captured by our CPOE system to evaluate how clinicians responded to an alert. We evaluated an alert designed to implement an institutional policy restricting the indications for ordering creatine kinase-MB (CKMB). Within 2 months of alert implementation, CKMB-associated searches declined by 79% with a corresponding decline in CKMB orders. Furthermore, while prior to alert implementation, clinicians searching for CKMB ultimately ordered this test 99% of the time, following implementation, only 60% of CKMB searches ultimately led to CKMB test orders. This difference presumably represents clinicians who reconsidered the need for CKMB in response to the alert, demonstrating the alert's just-in-time advisory capability. In addition, as clinicians repeatedly viewed the alert, there was a "dose-dependant" decrease in the fraction of searches without orders. This presumably reflects the alerting strategy's long-term educational component, as clinicians aware of the new policy will not search for CKMB when not indicated. Our analytic approach provides insight into the mechanism of a CPOE alert and demonstrates that alerts may act through a combination of just-in-time advice and longer term education. Use of this approach when implementing alerts may prove useful to improve the success of a given alerting strategy.

  1. Physicians' Perceptions on the usefulness of contextual information for prioritizing and presenting alerts in computerized physician order entry systems

    NARCIS (Netherlands)

    Jung, Martin; Riedmann, Daniel; Hackl, Werner O.; Hoerbst, Alexander; Jaspers, Monique W.; Ferret, Laurie; Lawton, Kitta; Ammenwerth, Elske

    2012-01-01

    Background: One possible approach towards avoiding alert overload and alert fatigue in Computerized Physician Order Entry (CPOE) systems is to tailor their drug safety alerts to the context of the clinical situation. Our objective was to identify the perceptions of physicians on the usefulness of

  2. Advantages and Disadvantages of Educational Email Alerts for Family Physicians: Viewpoint

    Science.gov (United States)

    Badran, Hani; Grad, Roland

    2015-01-01

    Background Electronic knowledge resources constitute an important channel for accredited Continuing Medical Education (CME) activities. However, email usage for educational purposes is controversial. On the one hand, family physicians become aware of new information, confirm what they already know, and obtain reassurance by reading educational email alerts. Email alerts can also encourage physicians to search Web-based resources. On the other hand, technical difficulties and privacy issues are common obstacles. Objective The purpose of this discussion paper, informed by a literature review and a small qualitative study, was to understand family physicians’ knowledge, attitudes, and behavior in regard to email in general and educational emails in particular, and to explore the advantages and disadvantages of educational email alerts. In addition, we documented participants’ suggestions to improve email alert services for CME. Methods We conducted a qualitative descriptive study using the “Knowledge, Attitude, Behavior” model. We conducted semi-structured face-to-face interviews with 15 family physicians. We analyzed the collected data using inductive-deductive thematic qualitative data analysis. Results All 15 participants scanned and prioritized their email, and 13 of them checked their email daily. Participants mentioned (1) advantages of educational email alerts such as saving time, convenience and valid information, and (2) disadvantages such as an overwhelming number of emails and irrelevance. They offered suggestions to improve educational email. Conclusions The advantages of email alerts seem to compensate for their disadvantages. Suggestions proposed by family physicians can help to improve educational email alerts. PMID:25803184

  3. A clinical data warehouse-based process for refining medication orders alerts.

    Science.gov (United States)

    Boussadi, Abdelali; Caruba, Thibaut; Zapletal, Eric; Sabatier, Brigitte; Durieux, Pierre; Degoulet, Patrice

    2012-01-01

    The objective of this case report is to evaluate the use of a clinical data warehouse coupled with a clinical information system to test and refine alerts for medication orders control before they were fully implemented. A clinical decision rule refinement process was used to assess alerts. The criteria assessed were the frequencies of alerts for initial prescriptions of 10 medications whose dosage levels depend on renal function thresholds. In the first iteration of the process, the frequency of the 'exceeds maximum daily dose' alerts was 7.10% (617/8692), while that of the 'under dose' alerts was 3.14% (273/8692). Indicators were presented to the experts. During the different iterations of the process, 45 (16.07%) decision rules were removed, 105 (37.5%) were changed and 136 new rules were introduced. Extensive retrospective analysis of physicians' medication orders stored in a clinical data warehouse facilitates alert optimization toward the goal of maximizing the safety of the patient and minimizing overridden alerts.

  4. Automaticity of phasic alertness: Evidence for a three-component model of visual cueing.

    Science.gov (United States)

    Lin, Zhicheng; Lu, Zhong-Lin

    2016-10-01

    The automaticity of phasic alertness is investigated using the attention network test. Results show that the cueing effect from the alerting cue-double cue-is strongly enhanced by the task relevance of visual cues, as determined by the informativeness of the orienting cue-single cue-that is being mixed (80 % vs. 50 % valid in predicting where the target will appear). Counterintuitively, the cueing effect from the alerting cue can be negatively affected by its visibility, such that masking the cue from awareness can reveal a cueing effect that is otherwise absent when the cue is visible. Evidently, then, top-down influences-in the form of contextual relevance and cue awareness-can have opposite influences on the cueing effect from the alerting cue. These findings lead us to the view that a visual cue can engage three components of attention-orienting, alerting, and inhibition-to determine the behavioral cueing effect. We propose that phasic alertness, particularly in the form of specific response readiness, is regulated by both internal, top-down expectation and external, bottom-up stimulus properties. In contrast to some existing views, we advance the perspective that phasic alertness is strongly tied to temporal orienting, attentional capture, and spatial orienting. Finally, we discuss how translating attention research to clinical applications would benefit from an improved ability to measure attention. To this end, controlling the degree of intraindividual variability in the attentional components and improving the precision of the measurement tools may prove vital.

  5. Advantages and disadvantages of educational email alerts for family physicians: viewpoint.

    Science.gov (United States)

    Badran, Hani; Pluye, Pierre; Grad, Roland

    2015-02-27

    Electronic knowledge resources constitute an important channel for accredited Continuing Medical Education (CME) activities. However, email usage for educational purposes is controversial. On the one hand, family physicians become aware of new information, confirm what they already know, and obtain reassurance by reading educational email alerts. Email alerts can also encourage physicians to search Web-based resources. On the other hand, technical difficulties and privacy issues are common obstacles. The purpose of this discussion paper, informed by a literature review and a small qualitative study, was to understand family physicians' knowledge, attitudes, and behavior in regard to email in general and educational emails in particular, and to explore the advantages and disadvantages of educational email alerts. In addition, we documented participants' suggestions to improve email alert services for CME. We conducted a qualitative descriptive study using the "Knowledge, Attitude, Behavior" model. We conducted semi-structured face-to-face interviews with 15 family physicians. We analyzed the collected data using inductive-deductive thematic qualitative data analysis. All 15 participants scanned and prioritized their email, and 13 of them checked their email daily. Participants mentioned (1) advantages of educational email alerts such as saving time, convenience and valid information, and (2) disadvantages such as an overwhelming number of emails and irrelevance. They offered suggestions to improve educational email. The advantages of email alerts seem to compensate for their disadvantages. Suggestions proposed by family physicians can help to improve educational email alerts.

  6. [Detection of Brucella with an automatic hemoculture system: Bact/Alert].

    Science.gov (United States)

    Casas, J; Partal, Y; Llosá, J; Leiva, J; Navarro, J M; de la Rosa, M

    1994-12-01

    The ability of in vitro and in vivo detection of Brucella spp. with the Bact/Alert system was studied. Three strains of Brucella melitensis and two of Brucella abortus were used. Different dilutions of the five strains were performed in trypticase soy broth (TSB), achieving concentrations of 1 cfu/ml, 5 cfu/ml, 10 cfu/ml and 100 cfu/ml. Ten ml of each dilution and strain were inoculated into 5 aerobic bottles Bact/Alert and 5 biphasic Hemóline bottles. Furthermore, over a 9 month period, 8,216 bottles of Bact/Alert bottles from hospitalized patients and from the emergency department were processed in the authors' laboratory. The mean detection time for Brucella growth was from 2 to 3 days with the Bact/Alert system, and 14 days in the biphasic bottles. Former bottles processed in the authors' laboratory, 11 aerobic bottles belonged to 5 patients in whom brucelosis was confirmed by bloodculture. The Bact/Alert system detected Brucella melitensis in only on bottle at 2.9 days of incubation. In 7 bottles Bact/Alert detected B. melitensis by a blind pass of these bottles at 10 to 20 days of incubation. These results suggest that the Bact/Alert system does not totally solve the diagnosis of brucellosis. Blind passes of the bloodcultures are required.

  7. Generalized Philosophy of Alerting with Applications for Parallel Approach Collision Prevention

    Science.gov (United States)

    Winder, Lee F.; Kuchar, James K.

    2000-01-01

    The goal of the research was to develop formal guidelines for the design of hazard avoidance systems. An alerting system is automation designed to reduce the likelihood of undesirable outcomes that are due to rare failures in a human-controlled system. It accomplishes this by monitoring the system, and issuing warning messages to the human operators when thought necessary to head off a problem. On examination of existing and recently proposed logics for alerting it appears that few commonly accepted principles guide the design process. Different logics intended to address the same hazards may take disparate forms and emphasize different aspects of performance, because each reflects the intuitive priorities of a different designer. Because performance must be satisfactory to all users of an alerting system (implying a universal meaning of acceptable performance) and not just one designer, a proposed logic often undergoes significant piecemeal modification before gamma general acceptance. This report is an initial attempt to clarify the common performance goals by which an alerting system is ultimately judged. A better understanding of these goals will hopefully allow designers to reach the final logic in a quicker, more direct and repeatable manner. As a case study, this report compares three alerting logics for collision prevention during independent approaches to parallel runways, and outlines a fourth alternative incorporating elements of the first three, but satisfying stated requirements. Three existing logics for parallel approach alerting are described. Each follows from different intuitive principles. The logics are presented as examples of three "philosophies" of alerting system design.

  8. Effects of chewing gum and time-on-task on alertness and attention.

    Science.gov (United States)

    Allen, A P; Smith, A P

    2012-07-01

    Chewing gum has been shown to reliably increase subjective alertness whereas the effects on attention are more variable. It has been suggested that chewing gum only enhances attention when the person has been performing a task for some time. The current research aimed to investigate if time-on-task trends enhancing effects of chewing gum could be observed in alertness and attention during and following chewing. Study 1 used tests of reported mood, including reported mood, and tests of attention (categoric search, focussed attention, simple reaction time, and vigilance). These tasks were performed shortly after the start of chewing. Study 2 examined effects of previous and current chewing on reported alertness and the attention tests. Study 1 showed that chewing gum increased reported alertness and hedonic tone and improved performance on the categoric search task. Chewing gum maintained reported alertness across sessions in study 2. In the first experimental session of study 2 gum improved categoric search performance, and during the second session gum broadened focus of attention and quickened vigilance reaction time. This effect on vigilance reaction time was moderated by time-on-task, with an initial negative effect being replaced by a positive effect. The results confirm the robust effect of chewing gum on reported alertness and show that changes in the effects of chewing gum on attention require further investigation. Future research may also determine underlying mechanisms for an alerting effect.

  9. Collaborative knowledge acquisition for the design of context-aware alert systems.

    Science.gov (United States)

    Joffe, Erel; Havakuk, Ofer; Herskovic, Jorge R; Patel, Vimla L; Bernstam, Elmer Victor

    2012-01-01

    To present a framework for combining implicit knowledge acquisition from multiple experts with machine learning and to evaluate this framework in the context of anemia alerts. Five internal medicine residents reviewed 18 anemia alerts, while 'talking aloud'. They identified features that were reviewed by two or more physicians to determine appropriate alert level, etiology and treatment recommendation. Based on these features, data were extracted from 100 randomly-selected anemia cases for a training set and an additional 82 cases for a test set. Two staff internists assigned an alert level, etiology and treatment recommendation before and after reviewing the entire electronic medical record. The training set of 118 cases (100 plus 18) and the test set of 82 cases were explored using RIDOR and JRip algorithms. The feature set was sufficient to assess 93% of anemia cases (intraclass correlation for alert level before and after review of the records by internists 1 and 2 were 0.92 and 0.95, respectively). High-precision classifiers were constructed to identify low-level alerts (precision p=0.87, recall R=0.4), iron deficiency (p=1.0, R=0.73), and anemia associated with kidney disease (p=0.87, R=0.77). It was possible to identify low-level alerts and several conditions commonly associated with chronic anemia. This approach may reduce the number of clinically unimportant alerts. The study was limited to anemia alerts. Furthermore, clinicians were aware of the study hypotheses potentially biasing their evaluation. Implicit knowledge acquisition, collaborative filtering and machine learning were combined automatically to induce clinically meaningful and precise decision rules.

  10. Implementation Of CAN Based Intelligent Driver Alert System

    Directory of Open Access Journals (Sweden)

    Yin Mar Win Kyaw Myo Maung Maung

    2015-08-01

    Full Text Available This system is an attempt to analyze Intelligent Driver Alert System Using CAN Protocol. CAN Controller Area Network offer an efficient communication protocol among sensors actuators controllers and other nodes in real-time applications and is known for its simplicity reliability and high performance. It has given an effective way by which can increase the car and driver safety. This system presents the development and implementation of a digital driving system for a semi-autonomous vehicle to improve the driver-vehicle interface using microcontroller based data acquisition system that uses ADC to bring all control data from analog to digital format. In this system the signal information like temperature LM35 sensor if the temperature increase above the 60 o C and ultrasonic sensor is adapted to measure the distance between the object and vehicle if obstacle is detected within 75cm from the vehicle the controller gives buzzer to the driver speed measure using RPM sensor if revolution increase up to 1200 per minute controller act and to avoid the maximum revolution and to check the fuel level continuously and display in the percentage if fuel level below 20 percent the controller also gives buzzer to the driver and distance fuel level and temperature continuously display on the LCD.

  11. IP Telephony Based Danger Alert Communication System and Its Implementation

    Directory of Open Access Journals (Sweden)

    Filip Rezac

    2012-01-01

    Full Text Available The paper deals with development of a web application allowing to deliver pre-recorded voice messages by using SIP generator. The developed application is a part of complex system, which has been evolved in Dpt. of Telecommunications, Technical University of Ostrava for last three years. Our intent is focused on disaster management, the message, which should be delivered within specified time span, is typed in the application and text-to-speech module ensures its transormation to a speech format, after that a particular scenario or warned area is selected and a target group is automatically unloaded. For this purpose, we have defined XML format for delivery of phone numbers which are located in the target area and these numbers are obtained from mobile BTS's (Base transmission stations. The advantage of this aproach lies in controlled delivery and finally the list of unanswered calls is exported and these users are informed via SMS. In the paper, the core of the danger alert system is described including algorithms of the voice message delivery.

  12. The effect of petroleum spills on permafrost at CFS Alert

    International Nuclear Information System (INIS)

    Haidar, S.; Jarrett, P.

    1997-01-01

    Site investigations have been carried out at two decommissioned tank farm sites at Canadian Forces Station Alert on the northern tip of Ellesmere Island. The purpose was to study the mechanism of spilt fuel movement in frozen ground and its effects on frozen soils. The investigations consisted of sampling to depths below the permafrost table to assess vertical fuel migration, hydrocarbon pollutant concentration and water content. Results showed vertical migration of spilled fuel into permafrost. The migration was attributed to gravity drainage through interconnected air voids in fill material or movement through fissures in the soil induced by thermal contraction. Unweathered contaminants were found below the liners on top of the permafrost, believed to have been caused by holes in the liner. The entrapment of the spilled fuel may have been responsible for the enhanced vertical migration of contaminants observed at these sites. It was concluded that permafrost should not be considered as an impermeable barrier to contaminants with freezing points below 0 degree C. 4 figs

  13. Swift Burst Alert Telescope Data Products and Analysis Software

    International Nuclear Information System (INIS)

    Krimm, Hans A.; Barbier, Louis M.; Barthelmy, Scott D.; Cummings, Jay R.; Gehrels, Neil; Parsons, Ann M.; Tueller, Jack; Fenimore, Edward E.; Palmer, David M.; Hullinger, Derek D.; Markwardt, Craig B.

    2004-01-01

    The Burst Alert Telescope (BAT) on the Swift gamma-ray burst mission serves as the GRB trigger for Swift as well as a sensitive imaging telescope for the energy range of 15-150 keV. All BAT data products will be available to the astronomical community along with a complete set of analysis tools. Gamma-ray burst data products include rapid discovery messages delivered immediately via the GRB Coordinates Network, and event-by-event data from which light curves and spectra of the burst are generated. During nominal operations, the instrument provides accumulated survey histograms with 5-minute time sampling and appropriate energy resolution. These survey accumulations are analyzed in a pipeline to detect new sources and derive light curves of known sources. The 5-minute surveys will also be combined to produce the BAT all sky hard X-ray survey. In addition, the instrument accumulates high time resolution light curves of the brightest BAT sources in multiple energy bands, which are merged into a source light curve database on the ground. The BAT science data products and analysis tools will be described in this paper

  14. Technical features of a low-cost earthquake alert system

    International Nuclear Information System (INIS)

    Harben, P.

    1991-01-01

    The concept and features of an Earthquake Alert System (EAS) involving a distributed network of strong motion sensors is discussed. The EAS analyzes real-time data telemetered to a central facility and issues an areawide warning of a large earthquake in advance of the spreading elastic wave energy. A low-cost solution to high-cost estimates for installation and maintenance of a dedicated EAS is presented that makes use of existing microseismic stations. Using the San Francisco Bay area as an example, we show that existing US Geological Survey microseismic monitoring stations are of sufficient density to form the elements of a prototype EAS. By installing strong motion instrumentation and a specially developed switching device, strong ground motion can be telemetered in real-time to the central microseismic station on the existing communication channels. When a large earthquake occurs, a dedicated real-time central processing unit at the central microseismic station digitizes and analyzes the incoming data and issues a warning containing location and magnitude estimations. A 50-station EAS of this type in the San Francisco Bay area should cost under $70,000 to install and less than $5,000 annually to maintain

  15. SAFETY ALERT: Electrical insulation defect on safety helmets

    CERN Multimedia

    HSE Unit

    2013-01-01

    Contrarily to the information provided until 31 May 2013, some “Euro Protection” safety helmets do not respect any of the requirements for electrical insulation.   This alert concerns the safety helmets identified under the following SCEM numbers: 50.43.30.050.4 white 50.43.30.060.2 yellow 50.43.30.070.0 blue This amounts up to several hundreds of helmets on the CERN site. People who need to wear an electrically insulated safety helmet for their activities, must from now on acquire a duly insulated item to be found on the CERN store under the following SCEM numbers: 50.43.30.210.6: Petzl Vertex ST Helmet (without vent) 50.43.30.300.1: IDRA Helmet with a visor for electrical work As for the people who do not need to wear an electrically insulated helmet for their activities, they can continue working with the aforementioned helmets. For your information, please take note of the maximum use limit of each helmet: “Euro Protection” Safety Helme...

  16. SUBJECTIVE AND INDIRECT METHODS TO OBSERVE DRIVER’S DROWSINESS AND ALERTNESS: AN OVERVIEW

    Directory of Open Access Journals (Sweden)

    NOR KAMALIANA K.

    2016-04-01

    Full Text Available The measurement of drivers' workload has great interest these days due to the following reasons: high numbers of accidents seemingly ineradicable, very costly, and largely attributable to the human factor. The objective of this review is to assess the current status of fatigue performance and detection technology research and to identify any pertinent issues. Twenty-six relevant studies were identified and chosen from electronic databases, dating as far back as 1997. Fatigue, drowsiness, alertness, sleepiness, subjective, direct method and driver were the keyword search terms for this paper. Past studies demonstrated various purposes and implementation of subjective and indirect assessment among the driver for evaluating fatigue. It provides a better understanding for future researchers and industry to deal with fatigue issues among drivers. This review will provide a critical discussion on the designs used, discuss the findings in the search of directions for future studies, as well as provide insights into the use of counter measures for preventing fatigue-related accidents.

  17. An Unobtrusive Fall Detection and Alerting System Based on Kalman Filter and Bayes Network Classifier.

    Science.gov (United States)

    He, Jian; Bai, Shuang; Wang, Xiaoyi

    2017-06-16

    Falls are one of the main health risks among the elderly. A fall detection system based on inertial sensors can automatically detect fall event and alert a caregiver for immediate assistance, so as to reduce injuries causing by falls. Nevertheless, most inertial sensor-based fall detection technologies have focused on the accuracy of detection while neglecting quantization noise caused by inertial sensor. In this paper, an activity model based on tri-axial acceleration and gyroscope is proposed, and the difference between activities of daily living (ADLs) and falls is analyzed. Meanwhile, a Kalman filter is proposed to preprocess the raw data so as to reduce noise. A sliding window and Bayes network classifier are introduced to develop a wearable fall detection system, which is composed of a wearable motion sensor and a smart phone. The experiment shows that the proposed system distinguishes simulated falls from ADLs with a high accuracy of 95.67%, while sensitivity and specificity are 99.0% and 95.0%, respectively. Furthermore, the smart phone can issue an alarm to caregivers so as to provide timely and accurate help for the elderly, as soon as the system detects a fall.

  18. Design and implementation of a marine animal alert system to support Marine Renewable Energy

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Zhiqun; Carlson, Thomas J.; Fu, Tao; Ren, Huiying; Martinez, Jayson J.; Myers, Joshua R.; Matzner, Shari; Choi, Eric Y.; Copping, Andrea E.

    2013-08-08

    Power extracted from fast moving tidal currents has been identified as a potential commercial-scale source of renewable energy. Device developers and utilities are pursuing deployment of prototype tidal turbines to assess technology viability, site feasibility, and environmental interactions. Deployment of prototype turbines requires permits from a range of regulatory authorities. Ensuring the safety of marine animals, particularly those under protection of the Endangered Species Act of 1973 (ESA) and the Marine Mammal Protection Act of 1972 has emerged as a key regulatory challenge for initial MHK deployments. The greatest perceived risk to marine animals is from strike by the rotating blades of tidal turbines. Development of the marine mammal alert system (MAAS) was undertaken to support monitoring and mitigation requirements for tidal turbine deployments. The prototype system development focused on Southern Resident killer whales (SRKW), an endangered population of killer whales that frequents Puget Sound and is intermittently present in the part of the sound where deployment of prototype tidal turbines is being considered. Passive acoustics were selected as the primary means because of the vocal nature of these animals. The MAAS passive acoustic system consists of two-stage process involving the use of an energy detector and a spectrogram-based classifier to distinguish between SKRW’s calls and noise. A prototype consisting of two 2D symmetrical star arrays separated by 20 m center to center was built and evaluated in the waters of Sequim Bay using whale call playback.

  19. Methods uncovering usability issues in medication-related alerting functions: results from a systematic review.

    Science.gov (United States)

    Marcilly, Romaric; Vasseur, Francis; Ammenwerth, Elske; Beuscart-Zephir, Marie-Catherine

    2014-01-01

    This paper aims at listing the methods used to evaluate the usability of medication-related alerting functions and at knowing what type of usability issues those methods allow to detect. A sub-analysis of data from this systematic review has been performed. Methods applied in the included papers were collected. Then, included papers were sorted in four types of evaluation: "expert evaluation", "user- testing/simulation", "on site observation" and "impact studies". The types of usability issues (usability flaws, usage problems and negative outcomes) uncovered by those evaluations were analyzed. Results show that a large set of methods are used. The largest proportion of papers uses "on site observation" evaluation. This is the only evaluation type for which every kind of usability flaws, usage problems and outcomes are detected. It is somehow surprising that, in a usability systematic review, most of the papers included use a method that is not often presented as a usability method. Results are discussed about the opportunity to provide usability information collected after the implementation of the technology during their design process, i.e. before their implementation.

  20. Geothermal energy. Ground source heat pumps

    International Nuclear Information System (INIS)

    2009-01-01

    Geothermal energy can be harnessed in 2 different ways: electricity or heat generation. The combined net electrical geothermal power of the European Union countries reached 719.3 MWe in 2008 (4.8 MW up on 2007) for 868.1 MWe of installed capacity. Gross electrical production contracted slightly in 2008 (down 1% on the 2007 level) and stood at 5809.5 GWh in 2008. Italy has a overwhelming position with a production of 5520.3 GWh. Geothermal heat production concerning aquifers whose temperature is 30-150 C. degrees generally at a depth of 1-3 km is called low- and medium-enthalpy energy. 18 of the 27 EU members use low- and medium-enthalpy energy totaling 2560.0 MWth of installed capacity that yielded 689.2 ktoe in 2008 and 3 countries Hungary, Italy and France totaling 480.3 ktoe. Very low-enthalpy energy concerns the exploitation of shallow geothermal resources using geothermal heat pumps. In 2008, 114452 ground heat pumps were sold in Europe. At the end of 2008, the installed capacity was 8955.4 MWth (16.5% up on 2007 level, it represented 785206 pumps. Over one million ground heat pumps are expected to be operating in 2010 in Europe. (A.C.)

  1. Evening use of light-emitting eReaders negatively affects sleep, circadian timing, and next-morning alertness.

    Science.gov (United States)

    Chang, Anne-Marie; Aeschbach, Daniel; Duffy, Jeanne F; Czeisler, Charles A

    2015-01-27

    In the past 50 y, there has been a decline in average sleep duration and quality, with adverse consequences on general health. A representative survey of 1,508 American adults recently revealed that 90% of Americans used some type of electronics at least a few nights per week within 1 h before bedtime. Mounting evidence from countries around the world shows the negative impact of such technology use on sleep. This negative impact on sleep may be due to the short-wavelength-enriched light emitted by these electronic devices, given that artificial-light exposure has been shown experimentally to produce alerting effects, suppress melatonin, and phase-shift the biological clock. A few reports have shown that these devices suppress melatonin levels, but little is known about the effects on circadian phase or the following sleep episode, exposing a substantial gap in our knowledge of how this increasingly popular technology affects sleep. Here we compare the biological effects of reading an electronic book on a light-emitting device (LE-eBook) with reading a printed book in the hours before bedtime. Participants reading an LE-eBook took longer to fall asleep and had reduced evening sleepiness, reduced melatonin secretion, later timing of their circadian clock, and reduced next-morning alertness than when reading a printed book. These results demonstrate that evening exposure to an LE-eBook phase-delays the circadian clock, acutely suppresses melatonin, and has important implications for understanding the impact of such technologies on sleep, performance, health, and safety.

  2. Real-time Seismic Alert System of NIED

    Science.gov (United States)

    Horiuchi, S.; Fujinawa, Y.; Negishi, H.; Matsumoto, T.; Fujiwara, H.; Kunugi, T.; Hayashi, Y.

    2001-12-01

    An extensive seismic network has been constructed nationwide composed of hi-sensitivity seismographic network, broadband seismographic network and strong motion seismographic network. All these data from some 3,000 sites belonging to NIED, JMA and universities are to be accumulated and distributed through NIED to any scientists and engineering through INTERNET under the coordination of the National Seismic Research Committee of MEXT. As a practical application of those data we are now developing a real-time seismic alert information system for the purpose of providing short-term warning of imminent strong grounds motions from major earthquakes from several seconds to a few days. The contents of information are seismic focal parameters (several seconds), seismic fault plane solutions (some 10 seconds), after-shock activities (several minutes-a few days ). The fundamental fault parameters are used to build specific information at sites for particular users for use of triggering automated and /or half-automated responses. The most important application is an immediate estimate of expected shaking distribution and damages in a district using synthetic database and site effects for local governments to initial proper measures of hazard mitigation. Another application is estimation of arrival time and shaking strength at any individual site for human lives to be safeguarded. The system could also start an automatic electrical isolation and protection of computer systems, protection of hazardous chronic systems, transportation systems and so on. The information are corrected successively as seismic ground motion are received at a larger number of sites in time with the result that more accurate and more sophisticated earthquake information is transmitted to any user. Besides the rapid determination of seismic parameters, one of essential items in this alert system is the data transmission means. The data transmission is chosen to assure negligibly small delay of data

  3. Health Alert: Adrenal Crisis Causes Death in Some People Who Were Treated with hGH

    Science.gov (United States)

    ... Were Treated with hGH Health Alert: Adrenal Crisis Causes Death in Some People Who Were Treated with hGH ... Adrenal crisis is a serious condition that can cause death in people who lack the pituitary hormone ACTH. ...

  4. Space Environment Automated Alerts and Anomaly Analysis Assistant (SEA^5) for NASA

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop a comprehensive analysis and dissemination system (Space Environment Automated Alerts  & Anomaly Analysis Assistant: SEA5) that will...

  5. Enforcement Alert: EPA Enforcement Efforts Focus on Prevention of Chemical Accidents

    Science.gov (United States)

    This Alert is intended to inform the industry that companies must take responsibility to prevent accidental releases of dangerous chemicals like anhydrous ammonia through compliance with CAA’s Chemical Accident Prevention Program.

  6. Wireless Sensor Node for Autonomous Monitoring and Alerts in Remote Environments

    Science.gov (United States)

    Monacos, Steve P. (Inventor); Panangadan, Anand V. (Inventor)

    2015-01-01

    A method, apparatus, system, and computer program products provides personal alert and tracking capabilities using one or more nodes. Each node includes radio transceiver chips operating at different frequency ranges, a power amplifier, sensors, a display, and embedded software. The chips enable the node to operate as either a mobile sensor node or a relay base station node while providing a long distance relay link between nodes. The power amplifier enables a line-of-sight communication between the one or more nodes. The sensors provide a GPS signal, temperature, and accelerometer information (used to trigger an alert condition). The embedded software captures and processes the sensor information, provides a multi-hop packet routing protocol to relay the sensor information to and receive alert information from a command center, and to display the alert information on the display.

  7. Factors affecting driver alertness during the operation of haul trucks in the South African mining industry

    CSIR Research Space (South Africa)

    Schutte, PC

    2003-06-01

    Full Text Available In view of the seriousness of haul trucks accidents, SIMRAC initiated research to identify factors affecting haul truck driver alertness during mining operations. The information obtained during the risk analysis was used to identify possible...

  8. Alerting and vitalizing effects of color temperature during daytime: findings on subjective and objective indicators

    NARCIS (Netherlands)

    Smolders, K.C.H.J.; Kort, de Y.A.W.; Haans, A.; Gennip, van D. A. P.; Ham, J.; Kort, de Y. A. W.

    2011-01-01

    We investigated the effects of correlated colour temperature on alertness, vitality and performance during daytime. Results of a within-groups experiment demonstrate time dependent effects on subjective indicators; objective measures are still being analysed.

  9. A review of human factors principles for the design and implementation of medication safety alerts in clinical information systems.

    Science.gov (United States)

    Phansalkar, Shobha; Edworthy, Judy; Hellier, Elizabeth; Seger, Diane L; Schedlbauer, Angela; Avery, Anthony J; Bates, David W

    2010-01-01

    The objective of this review is to describe the implementation of human factors principles for the design of alerts in clinical information systems. First, we conduct a review of alarm systems to identify human factors principles that are employed in the design and implementation of alerts. Second, we review the medical informatics literature to provide examples of the implementation of human factors principles in current clinical information systems using alerts to provide medication decision support. Last, we suggest actionable recommendations for delivering effective clinical decision support using alerts. A review of studies from the medical informatics literature suggests that many basic human factors principles are not followed, possibly contributing to the lack of acceptance of alerts in clinical information systems. We evaluate the limitations of current alerting philosophies and provide recommendations for improving acceptance of alerts by incorporating human factors principles in their design.

  10. Should people be physically active outdoors on smog alert days?

    Science.gov (United States)

    Campbell, Monica E; Li, Qian; Gingrich, Sarah E; Macfarlane, Ronald G; Cheng, Shouquan

    2005-01-01

    Given the importance of physical activity to well-being, there is a need to encourage people to be physically active year-round. At the same time, many people are vulnerable to adverse health effects from air pollution, especially on smog alert days. This study was undertaken to determine when air pollution levels tend to be lowest so that the public can modify strenuous outdoor activity accordingly. Existing hourly air pollution data for Toronto were analyzed to determine how pollutant levels varied from hour to hour throughout each 24-hour day, to identify the times when pollution levels are at their lowest on average. Pollutant levels vary throughout the day, with concentrations of some pollutants (such as ozone, particles and sulphur dioxide) being highest during mid-day, and others (such as carbon monoxide and nitrogen dioxide) being highest with morning rush hour. Overall, pollutant concentrations tend to be lowest before seven a.m. and after eight p.m. The public should be encouraged to maintain regular physical activity outdoors while monitoring any air pollution-related symptoms. The intensity of outdoor activity should be reduced, or activities replaced with indoor exercise, at those Air Quality Index (AQI) levels that trigger individual symptoms and when AQI values exceed 50. Where possible, strenuous activity should be taken when and where air pollution levels tend to be lowest, namely early in the morning and in low-traffic areas. More research is required to guide development of health protective advice on exercising when air quality is poor.

  11. [Importance of health CRM in pandemics and health alerts].

    Science.gov (United States)

    Cubillas, Juan José; Ramos, María Isabel; Feito, Francisco R; González, José María; Gersol, Rafael; Ramos, María Belén

    2015-05-01

    The aim of this article is to demonstrate the importance of the role a health CRM can play in a pandemic or health alert. During the influenza-A pandemic, Salud Responde played a very important role. Its main objective was to establish protocols and citizens advice lines that would avoid patients with mild influenza-A symptoms going to health centre. A triage system was developed around the Siebel CRM (software tool) to achieve this objective. This allowed the Salud Responde staff to establish the severity of the patient depending on the symptoms and the risk factors of the patient, as well as being able to inform, give health advice or refer the patient to medical centres if necessary. All patients (a total of 56,497) who were attended by Salud Responde within its influenza-A service portfolio have been included. Patients who were attended by Salud Responde. The data have been extracted from the Salud Responde data base. Salud Responde attended to 56,497 patients during the influenza-A pandemic, of whom 48,287 patients did not require health care. Salud Responde attended to 56,497 patients, of whom 48,287 patients did not require health care. Apart from any financial savings that this could entail, it contributed to minimising the pandemic, avoiding the patient having to go to a health centre to receive medical care or information, and prevented, to a great extent, the flooding of casualty departments. Copyright © 2014 Elsevier España, S.L.U. All rights reserved.

  12. Functional organization of area V2 in the alert macaque.

    Science.gov (United States)

    Peterhans, E; von der Heydt, R

    1993-05-01

    We studied the relation between anatomical structure and functional properties of cells in area V2 of the macaque. Visual function was assessed in the alert animal during fixation of gaze. Recording sites were reconstructed with respect to cortical lamination and the cytochrome oxidase pattern. We measured orientation and direction selectivity, end-stopping, sensitivity to binocular disparity and ocular dominance, and determined more complex functions like sensitivity to anomalous contours and lines defined by coherent motion. Orientation selectivity was found in all parts of area V2, with high frequencies in the pale and thick stripes of the cytochrome oxidase pattern, and with lower frequency in the thin stripes. Representations of anomalous contours were found in the pale and thick stripes with similar frequencies, but generally not in the thin stripes, which have been thought to process colour. Lines defined by coherent motion were most frequently represented in the thick stripes; they were less frequent in the pale stripes, and (as with anomalous contours) were not found in the thin stripes. Sensitivity to binocular disparity was found in all types of stripes, but more frequently in the thick stripes, where the exclusively binocular neurons were also concentrated. By contrast, no segregation was found for direction selectivity and end-stopping. All neuronal properties were distributed evenly across cortical laminae. We conclude that mechanisms for figure-ground segregation involve the pale and the thick stripes of the cytochrome oxidase pattern, perhaps with greater emphasis on 'shape from motion' and 'stereoscopic depth' in the thick stripes, while more elementary neuronal properties are distributed almost evenly across the stripe pattern.

  13. Shaping the Army’s Information Technology Acquisition Workforce in an Era of Outsourcing

    Science.gov (United States)

    2009-03-12

    10th, 1996), 679-703. 2 LTC Paul D. Briggs , The Army Information Technology Personnel Challenge (Are We Selling Our Seed Corn & Can We Buy It Back... Stephanie Overby, “Staff Alert,” CIO.com, May 1, 2003, http://www.cio.com/article/31868/Staff_Alert (accessed 3 October 2008). 20 US General Accounting

  14. Strengthening Laboratory Capacity for Early Warning Alert and Response System (EWARS) in Indonesia

    OpenAIRE

    Kandel, Nirmal; Hapsari, Ratna Budi; Riana, Dyah Armi; Setiawaty, Vivi; Larasati, Wita; Wulandari, Endang; Purwanto, Edy

    2017-01-01

    Background: Establishment of Early Warning Alert and Response System (EWARS) in Indonesia was initiated since 2009 in few selected provinces and government was planning to roll out in other provinces. Before initiating this roll out the assessment of performance of EWARS in 2012 was conducted. The aim of the assessment is to strengthen laboratory for supporting to EWARS for alerts testing. Methods: Laboratory capacity mapping tool and laboratory algorithm for twenty two priority diseases of ...

  15. Assigning a volcano alert level: negotiating uncertainty, risk, and complexity in decision-making processes

    OpenAIRE

    Carina J Fearnley

    2013-01-01

    A volcano alert level system (VALS) is used to communicate warning information from scientists to civil authorities managing volcanic hazards. This paper provides the first evaluation of how the decision-making process behind the assignation of an alert level, using forecasts of volcanic behaviour, operates in practice . Using interviews conducted from 2007 to 2009 at five USGS-managed (US Geological Survey) volcano observatories (Alaska, Cascades, Hawaii, Long Valley, and Yellowstone), two k...

  16. Project success: A methodological and evaluative case study of the early alert program interventions

    Science.gov (United States)

    Larkins, Randy James

    environment possible in whatever form the focus group takes place. Suggestions for future research include recruiting participants from online classes and attempting to engage more disenfranchised students in other studies. Similar to new types of focus group methods due to technological advances, academic interventions for students facing failing grades are also increasing due to the internet and new methods of service delivery. The contextual aspect of this research involved asking students to participate in an initial focus group session, four weeks of email updates, and a final focus group session in which students participated in the same group as the initial session. The purpose of the focus groups was to evaluate whether or not the universities' attempts to help students succeed in a course known in the past for high failure rates through a program known as the Early Alert Project was succeeding. Interview data were analyzed using thematic coding to evaluate available support services using a comprehensive implementation evaluation model which included effort, monitoring, process, components; and treatment specification. The primary findings were although students believed the university was trying to help them succeed, Early Alert Project efforts were adversely received. In addition, participants felt that although there were enough support services to help them succeed in the course, the components of the support system were confusing and not organized in any systematic manner. Suggestions for further research included researching delivery of this type of communication that might be more amenable to the students who received it and applying this research to other courses to examine whether the same results occur. Finally, implications of the use of traditional methods and academic support services are discussed in addition to the effect of the research itself upon its participants.

  17. A novel strategy for evaluating the effects of an electronic test ordering alert message: Optimizing cardiac marker use

    Directory of Open Access Journals (Sweden)

    Jason M Baron

    2012-01-01

    Full Text Available Background: Laboratory ordering functions within computerized provider order entry (CPOE systems typically support the display of electronic alert messages to improve test utilization or implement new ordering policies. However, alert strategies have been shown to vary considerably in their success and the characteristics contributing to an alert′s success are poorly understood. Improved methodologies are needed to evaluate alerts and their mechanisms of action. Materials and Methods: Clinicians order inpatient and emergency department laboratory tests using our institutional CPOE system. We analyzed user interaction data captured by our CPOE system to evaluate how clinicians responded to an alert. We evaluated an alert designed to implement an institutional policy restricting the indications for ordering creatine kinase-MB (CKMB. Results: Within 2 months of alert implementation, CKMB-associated searches declined by 79% with a corresponding decline in CKMB orders. Furthermore, while prior to alert implementation, clinicians searching for CKMB ultimately ordered this test 99% of the time, following implementation, only 60% of CKMB searches ultimately led to CKMB test orders. This difference presumably represents clinicians who reconsidered the need for CKMB in response to the alert, demonstrating the alert′s just-in-time advisory capability. In addition, as clinicians repeatedly viewed the alert, there was a "dose-dependant" decrease in the fraction of searches without orders. This presumably reflects the alerting strategy′s long-term educational component, as clinicians aware of the new policy will not search for CKMB when not indicated. Conclusions: Our analytic approach provides insight into the mechanism of a CPOE alert and demonstrates that alerts may act through a combination of just-in-time advice and longer term education. Use of this approach when implementing alerts may prove useful to improve the success of a given alerting

  18. Entrepreneurial alertness: Study of the Influence of Individual Characteristics and Entrepreneurship

    Directory of Open Access Journals (Sweden)

    Hilka Pelizza Vier Machado

    2016-01-01

    Full Text Available ABSTRACT This research tried to understand which statistical variables associated to the individual and the company influence the entrepreneurial alertness. The sample was constituted by 180 entrepreneurs. The entrepreneurial alertness was measured in agreement with the model of Tang, Kacmar and Busenitz (2012. Descriptive statistical tests and normality exam were developed; as well as checked the validity and reliability of the scale through Confirmatory Factor Analysis (CFA. In order to identify the factors that influenced the alertness we developed multiple linear regression and the ANOVA test to determine possible differences among groups (gender, education. The results showed the negative influence of the educational level and the size of enterprises on alertness level; as well as the negative relationship between age and entrepreneurial experience, furthermore, shows that alert level is not determined by gender difference. One of the main implications of this research is to present factors that can potentiate the effects of the entrepreneurial alertness, enlarging the possibilities of identification of opportunities for individuals.

  19. Control-room operator alertness and performance in nuclear power plants

    International Nuclear Information System (INIS)

    Baker, T.l.; Campbell, S.C.; Linder, K.D.; Moore-Ede, M.C

    1990-02-01

    All industries requiring round-the-clock operation must deal with the potential problem of impaired alertness, especially among those who work night shifts. In the nuclear power industry, maintaining optimal alertness and performance of control room operators at all times of day is critical. Many of the toot causes of reduced alertness are straightforward and can be easily remedied with tangible solutions; this manual both discusses the reasons for the problem and suggests solutions. The manual surveys factors that influence operator alertness and performance, including shift schedules, caffeine and alcohol use, diet and family lifestyle factors, the control room enviornment, staffing and overtime practices, and work task design. Specific recommendations are made in each of these areas. The project team, consisting of experts on managing round-the-clock operations and scientists who study human alertness and performance, prepared this manual using the latest scientific research and direct input from shift supervisors and operators via interviews, on-site observation, and questionnaires distributed to every nuclear power station. The material contained within is relevant to shiftwork managers, shift supervisors, and operators, each of whom plays a vital role in maintaining optimal alertness and performance on the job. 90 refs., 35 figs

  20. 太阳能与地源热泵复合系统的优化配置与运行方式%Optimizing configuring and running-mode of solar energy and ground-source heat pump hybrid systems

    Institute of Scientific and Technical Information of China (English)

    冯晓梅; 张昕宇; 邹瑜; 郑瑞澄

    2011-01-01

    以某实际工程为例,对太阳能系统与地源热泵系统联合运行时的优化配置与运行方式进行了模拟分析.得到结论:要优先利用太阳能系统;对太阳能资源要梯级利用;尽可能增大太阳能集热器面积,提高太阳能直接利用的可能性;单位面积太阳能集热器成本为250元/m2左右比较合适.%With a project, simulates and analyses optimizing configuring and running-mode of the hybrid system. Concludes that the solar energy system should be prior to the ground-source heat pump system in operation, the utilization of solar energy resource should be the way according to the energy grade, a possibly larger solar collector area is good for direct utilization of solar energy, and the solar collector cost of 250 RMB per square meter is appropriate.

  1. Energy efficiency ground-source energy system, Environmental Protection Law, article 'Heat and cold storage, value for money'; Energierendement bodemenergiesysteem, Wet milieubeheer, artikel 'WKO, waar voor je geld'

    Energy Technology Data Exchange (ETDEWEB)

    Lambregts, E.G.M.; Teunissen, P.O.M.; Beukenhorst, E.

    2013-01-15

    Upscaling of ground-source energy systems can contribute to heat and cold storage systems and thus reduce CO2 emission for the Amsterdam municipality. Based on the results of the project 'Heat and cold storage; Value for money' a proposal was made to the Dutch Ministry of Infrastructure and Environment to include a regulation 'energy efficiency heat and cold storage' in the Environmental Protection Law [Dutch] In het kader van de CO2 doelstelling van Amsterdam om 40% CO2 te reduceren in 2025 t.o.v. van 1990 wordt de verdere opschaling van de techniek bodemenergiesysteem gezien als een techniek die in belangrijke mate kan bijdragen aan de pijler 'transitie duurzame warmte en koude'. Op landelijk en gemeentelijk niveau werd gesignaleerd dat (open) bodemenergiesystemen in de exploitatiefase veelal onvoldoende functioneerden. In dit rapport wordt op basis van de resultaten van het project 'WKO, waar voor je geld' een voorstel aan het Ministerie van I en M gedaan om een voorschrift 'energierendement wko' op te nemen in het Activiteitenbesluit Wet milieubeheer.

  2. Field Demonstration of Ground-Source Integrated Heat Pump Part I. Technology and Field Demo System/Site Descriptions, and Preliminary Summer/Fall Performance Analysis for One Site

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, Van D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Munk, Jeffrey D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Gehl, Anthony C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-02-01

    The field study is planned to continue through the 2016 cooling season with the draft final project report due by September 30, 2016. This report provides a description of both installations and preliminary 2015 cooling and fall season performance results for the Knoxville site. For the August 18 through December 14 period, the Knoxville site GS-IHP provided 53.6% total source energy savings compared to a baseline electric RTU/heat pump and electric WH. Peak demand savings ranged from 33% to 59% per month. Energy cost savings of 53.1% have been achieved to date with more than half of that coming from reduced demand charges. Data on installation and maintenance costs are being collected and will be combined with total test period energy savings data for a payback analysis to be included in the project final report. The GS-IHP also saved a significant amount of carbon emissions. The total emission savings for the Knoxville site for the August-December 2015 period were ~0.8 metric tons. If trading for carbon credits ever becomes a reality, additional cost savings would be realized.

  3. 76 FR 12600 - Review of the Emergency Alert System

    Science.gov (United States)

    2011-03-08

    ... facilities may be based on a single technology or a combination of technologies. Establishments in this... significant holders of OVS certifications or local OVS franchises, even though OVS is one of four statutorily... regulatory burdens wherever possible. E. Steps Taken To Minimize the Significant Economic Impact on Small...

  4. Lessons for tsunami risk mitigation from recent events occured in Chile: research findings for alerting and evacuation from interdisciplinary perspectives

    Science.gov (United States)

    Cienfuegos, R.; Catalan, P. A.; Leon, J.; Gonzalez, G.; Repetto, P.; Urrutia, A.; Tomita, T.; Orellana, V.

    2016-12-01

    In the wake of the 2010 tsunami that hit Chile, a major public effort to promote interdisciplinary disaster reseach was undertaken by the Comisión Nacional de Investigación Científica y Tecnológica (Conicyt) allocating funds to create the Center for Integrated Research on Natural Risks Management (CIGIDEN). This effort has been key in promoting associativity between national and international research teams in order to transform the frequent occurrence of extreme events that affect Chile into an opportunity for interdisciplinary research. In this presentation we will summarize some of the fundamental research findings regarding tsunami forecasting, alerting, and evacuation processes based on interdisciplinary field work campaigns and modeling efforts conducted in the wake of the three most recent destructive events that hit Chile in 2010, 2014, and 2015. One of the main results that we shall emphatize from these findings, is that while research and operational efforts to model and forecast tsunamis are important, technological positivisms should not undermine educational efforts that have proved to be effective in reducing casualties due to tsunamis in the near field. Indeed, in recent events that hit Chile, first tsunami waves reached the adjacent generation zones in time scales comparable with the required time for data gathering and modeling even for the most sophisticated early warning tsunami algorithms currently available. The latter emphasizes self-evacuation from coastal areas, while forecasting and monitoring tsunami hazards remain very important for alerting more distant areas, and are essential for alert cancelling especially when shelf and embayment resonance, and edge wave propagation may produce destructive late tsunami arrivals several hours after the nucleation of the earthquake. By combining some of the recent evidence we have gathered in Chile on seismic source uncertainities (both epistemic and aleatoric), tsunami hydrodynamics, the response

  5. Decreased functional connectivity and structural deficit in alertness network with right-sided temporal lobe epilepsy.

    Science.gov (United States)

    Gao, Yujun; Zheng, Jinou; Li, Yaping; Guo, Danni; Wang, Mingli; Cui, Xiangxiang; Ye, Wei

    2018-04-01

    Patients with temporal lobe epilepsy (TLE) often suffer from alertness alterations. However, specific regions connected with alertness remain controversial, and whether these regions have structural impairment is also elusive. This study aimed to investigate the characteristics and neural mechanisms underlying the functions and structures of alertness network in patients with right-sided temporal lobe epilepsy (rTLE) by performing the attentional network test (ANT), resting-state functional magnetic resonance imaging (R-SfMRI), and diffusion tensor imaging (DTI).A total of 47 patients with rTLE and 34 healthy controls underwent ANT, R-SfMRI, and DTI scan. The seed-based functional connectivity (FC) method and deterministic tractography were used to analyze the data.Patients with rTLE had longer reaction times in the no-cue and double-cue conditions. However, no differences were noted in the alertness effect between the 2 groups. The patient group had lower FC compared with the control group in the right inferior parietal lobe (IPL), amygdala, and insula. Structural deficits were found in the right parahippocampal gyrus, superior temporal pole, insula, and amygdala in the patient group compared with the control group. Also significantly negative correlations were observed between abnormal fractional anisotropy (between the right insula and the superior temporal pole) and illness duration in the patients with rTLE.The findings of this study suggested abnormal intrinsic and phasic alertness, decreased FC, and structural deficits within the alerting network in the rTLE. This study provided new insights into the mechanisms of alertness alterations in rTLE.

  6. Generator replacement is associated with an increased rate of ICD lead alerts.

    Science.gov (United States)

    Lovelock, Joshua D; Cruz, Cesar; Hoskins, Michael H; Jones, Paul; El-Chami, Mikhael F; Lloyd, Michael S; Leon, Angel; DeLurgio, David B; Langberg, Jonathan J

    2014-10-01

    Lead malfunction is an important cause of morbidity and mortality in patients with an implantable cardioverter-defibrillator (ICD). We have shown that the failure of recalled high-voltage leads significantly increases after ICD generator replacement. However, generator replacement has not been recognized as a predictor of lead failure in general. The purpose of this study is to assess the effect of ICD generator exchange on the rate of ICD lead alerts. A time-dependent Cox proportional hazards model was used to analyze a database of remotely monitored ICDs. The model assessed the impact of generator exchange on the rate of lead alerts after ICD generator replacement. The analysis included 60,219 patients followed for 37 ± 19 months. The 5-year lead survival was 99.3% (95% confidence interval 99.2%-99.4%). Of 60,219 patients, 7458 patients (12.9%) underwent ICD generator exchange without lead replacement. After generator replacement, the rate of lead alerts was more than 5-fold higher than in controls with leads of the same age without generator replacement (hazard ratio 5.19; 95% confidence interval 3.45-7.84). A large number of lead alerted within 3 months of generator replacement. Lead alerts were more common in patients with single- vs dual-chamber ICDs and in younger patients. Sex was not associated with lead alerts. Routine generator replacement is associated with a 5-fold higher risk of lead alert compared to age-matched leads without generator replacement. This suggests the need for intense surveillance after generator replacement and the development of techniques to minimize the risk of lead damage during generator replacement. Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  7. EEG quantification of alertness: methods for early identification of individuals most susceptible to sleep deprivation

    Science.gov (United States)

    Berka, Chris; Levendowski, Daniel J.; Westbrook, Philip; Davis, Gene; Lumicao, Michelle N.; Olmstead, Richard E.; Popovic, Miodrag; Zivkovic, Vladimir T.; Ramsey, Caitlin K.

    2005-05-01

    Electroencephalographic (EEG) and neurocognitive measures were simultaneously acquired to quantify alertness from 24 participants during 44-hours of sleep deprivation. Performance on a three-choice vigilance task (3C-VT), paired-associate learning/memory task (PAL) and modified Maintenance of Wakefulness Test (MWT), and sleep technician-observed drowsiness (eye-closures, head-nods, EEG slowing) were quantified. The B-Alert system automatically classifies each second of EEG on an alertness/drowsiness continuum. B-Alert classifications were significantly correlated with technician-observations, visually scored EEG and performance measures. B-Alert classifications during 3C-VT, and technician observations and performance during the 3C-VT and PAL evidenced progressively increasing drowsiness as a result of sleep deprivation with a stabilizing effect observed at the batteries occurring between 0600 and 1100 suggesting a possible circadian effect similar to those reported in previous sleep deprivation studies. Participants were given an opportunity to take a 40-minute nap approximately 24-hours into the sleep deprivation portion of the study (i.e., 7 PM on Saturday). The nap was followed by a transient period of increased alertness. Approximately 8 hours after the nap, behavioral and physiological measures of drowsiness returned to levels prior to the nap. Cluster analysis was used to stratify individuals into three groups based on their level of impairment as a result of sleep deprivation. The combination of B-Alert and neuro-behavioral measures may identify individuals whose performance is most susceptible to sleep deprivation. These objective measures could be applied in an operational setting to provide a "biobehavioral assay" to determine vulnerability to sleep deprivation.

  8. Geothermal energy plants. Technologies and risk of soil and groundwater pollution; Jordvarmeanlaeg. Teknologier og risiko for jord- og grundvandsforurening

    Energy Technology Data Exchange (ETDEWEB)

    Villumsen, B. (COWI A/S, Kgs. Lyngby (Denmark))

    2008-07-01

    Ground source heat systems utilise the natural heat in the ground to heat houses and domestic hot water. The technology is energy-saving and can therefore contribute to the targets of reducing Denmark's CO{sub 2} emissions. All else being equal, a ground source heat system containing chemicals poses a potential contamination risk to soil and groundwater. Therefore a permit is required when installing a ground source heat system, and the general regulations for implementing the system etc. combined with the municipality's administrative procedures for the area must ensure sufficient protection of the groundwater. This project only deals with the heat exchanging system, which is the part of the ground source heat system which involves risk of soil and groundwater contamination. The aim of the project is to procure an overall updated knowledge base about the different types of ground source heat systems and the contamination risk associated with them. The project also reviews how disadvantages can be managed or minimized. (au)

  9. Analysis & Tools to Spur Increased Deployment of “Waste Heat” Rejection/Recycling Hybrid Ground-source Heat Pump Systems in Hot, Arid or Semiarid Climates Like Texas

    Energy Technology Data Exchange (ETDEWEB)

    Masada, Glenn [Univ. of Texas, Austin, TX (United States); Moon, Tess [Univ. of Texas, Austin, TX (United States)

    2013-09-01

    This project team analyzed supplemental heat rejection/recovery (SHR) devices or systems that could be used in hybrid ground source heat pump (HGHP) systems located in arid or semi-arid regions in southwestern U.S. Identification of effective SHR solutions would enhance the deployment of ground source heat pumps (GHP) in these regions. In a parallel effort, the team developed integrated GHP models that coupled the building load, heat pump, and ground loop subsystems and which could be applied to residential and commercial office buildings. Then GHP and HGHP performances could be compared in terms of operational performance and life-cycle costs. Several potential SHR devices were analyzed by applying two strategies: 1) to remove heat directly from the water in the ground loop before it enters the ground and 2) to remove heat in the refrigerant loop of the vapor compression cycle (VCC) of the heat pump so less heat is transferred to the water loop at the condenser of the VCC. Cooling towers, adsorption coolers, and thermoelectric liquid coolers were included in strategy 1, and expanded desuperheaters, thermosyphons, and an optimized VCC were included in strategy 2. Of all SHR devices analyzed, only the cooling tower provided a cost-effective performance enhancement. For the integrated GHP model, the project team selected the building load model HAMBASE and its powerful computational Simulink/MatLab platform, empirical performance map models of the heat pumps based upon manufacturers’ performance data, and a ground loop model developed by Oklahoma State University and rewritten for this project in Simulink/MatLab. The design process used GLHEPRO, also from Oklahoma State University, to size the borehole fields. The building load and ground loop models were compared with simulations from eQuest, ASHRAE 140-2008 standards, EnergyPlus, and GLHEPRO and were found to predict those subsystems’ performance well. The integrated GHP model was applied to a 195m2

  10. Operation strategy of solar-ground source heat pump systems%太阳能-地源热泵联合供能系统运行策略研究

    Institute of Scientific and Technical Information of China (English)

    王恩宇; 贺芳; 齐承英

    2012-01-01

    根据天津地区的气候条件,建立了太阳能-地源热泵多热源供热系统模型.利用TRNSYS软件对该系统进行了模拟研究,分析了系统用能情况及运行过程中地温的变化,着重对运行策略进行了研究.基于系统的性能系数选定的控制策略为:集热器出口与水箱出口温差大于15℃时启动集热,当温差小于2℃时停止集热;水箱出口温度高于50℃时启动储热,土壤进出口水温差不足5℃时停止储热.%Establishes a solar-ground source heat pump system model according to the climatic conditions in Tianjin. Carries out a simulation study of the system based on TRNSYS program, analyses the energy consumption of the system and the ground temperature change, and studies the operation strategy with emphasis. Selects an appropriate operation strategy based on the coefficient of performance (COP) of system, i. e. to turn on the solar collection pump as the temperature difference between collector outlet and tank outlet is higher than 15 ℃, and to turn off the pump until it is less than 2 ℃ , and to turn on the solar storage pump when tank outlet temperature is higher than 50 ℃ , and to turn off it until the temperature difference between inlet and outlet of the borehole heat exchanger is less than 5 ℃.

  11. Road safety alerting system with radar and GPS cooperation in a VANET environment

    Science.gov (United States)

    Santamaria, Amilcare Francesco; Sottile, Cesare; De Rango, Floriano; Voznak, Miroslav

    2014-05-01

    New applications in wireless environments are increasing and keeping even more interests from the developer companies and researchers. In particular, in these last few years the government and institutional organization for road safety spent a lot of resources and money to promote Vehicular Ad-Hoc Network (VANET) technology, also car manufactures are giving a lot of contributions on this field as well. In our paper, we propose an innovative system to increase road safety, matching the requests of the market allowing a cooperation between on-board devices. The vehicles are equipped with On Board Unit (OBU) and On Board Radar Unit (OBRU), which can spread alerting messages around the network regarding warning and dangerous situations exploiting IEEE802.llp standard. Vehicles move along roads observing the environment, traffic and road conditions, and vehicles parameters as well. These information can be elaborated and shared between neighbors, Road Side Unit (RSU)s and, of course, with Internet, allowing inter-system communications exploiting an Road Traffic Manager (RTM). Radar systems task it the detection of the environment in order to increase the knowledge of current conditions of the roads, for example it is important to identify obstacles, road accidents, dangerous situations and so on. Once detected exploiting onboard devices, such as Global Position System (GPS) receiver it is possible to know the exact location of the caught event and after a data elaboration the information is spread along the network. Once the drivers are advised, they can make some precautionary actions such as reduction of traveling speed or modification of current road path. In this work the routing algorithms, which have the main goal to rapidly disseminate information, are also been investigated.

  12. A Logic Architecture for 360 ADAS-Alerts for Hazards Detection Based in Driver Actions

    Directory of Open Access Journals (Sweden)

    Izquierdo-Reyes Javier

    2017-01-01

    Full Text Available In this work is presented a novel approach for passive safety in vehicles by Advanced Driver Assistance Systems (ADAS alert emission in 360° around driver to notify about hazards nearby the vehicle depending on the actions taken by driver per the context. This proposal would create a more robust system compared to current passive ADAS systems since the feedback to driver is in the same direction that hazard is detected (Punctual Sound Source Alert, compared with most assistance systems that emits sounds from the monitor or from the dashboard provoking distractions when emits alerts unnecessarily. The increase of security by this method will allow the driver to be aware of their surroundings even in a very quiet cabin or in a noisy environment. Also, it would detect the steering wheel angle, speed of movement and the activation of turning lights among other alerts, which would allow us to define a critical action during driving; apart from using sensors and cameras aimed at the driver to detect patterns of movement during these critical actions and have a prediction of a possible turn or manoeuvre when driving, refer to Figure 1. It will be necessary a reconfiguration of the alert in frequency, time of action depending upon the level of risk to prevent an accident or to reduce the consequences in an imminent accident.

  13. Alert: An Adaptive Low-Latency Event-Driven MAC Protocol for Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Vinod Namboodiri

    2011-01-01

    Full Text Available Collection of rare but delay-critical messages from a group of sensor nodes is a key process in many wireless sensor network applications. This is particularly important for security-related applications like intrusion detection and fire alarm systems. An event sensed by multiple sensor nodes in the network can trigger many messages to be sent simultaneously. We present Alert, a MAC protocol for collecting event-triggered urgent messages from a group of sensor nodes with minimum latency and without requiring any cooperation or prescheduling among the senders or between senders and receiver during protocol execution. Alert is designed to handle multiple simultaneous messages from different nodes efficiently and reliably, minimizing the overall delay to collect all messages along with the delay to get the first message. Moreover, the ability of the network to handle a large number of simultaneous messages does not come at the cost of excessive delays when only a few messages need to be handled. We analyze Alert and evaluate its feasibility and performance with an implementation on commodity hardware. We further compare Alert with existing approaches through simulations and show the performance improvement possible through Alert.

  14. Bioalerts: a python library for the derivation of structural alerts from bioactivity and toxicity data sets.

    Science.gov (United States)

    Cortes-Ciriano, Isidro

    2016-01-01

    Assessing compound toxicity at early stages of the drug discovery process is a crucial task to dismiss drug candidates likely to fail in clinical trials. Screening drug candidates against structural alerts, i.e. chemical fragments associated to a toxicological response prior or after being metabolized (bioactivation), has proved a valuable approach for this task. During the last decades, diverse algorithms have been proposed for the automatic derivation of structural alerts from categorical toxicity data sets. Here, the python library bioalerts is presented, which comprises functionalities for the automatic derivation of structural alerts from categorical (dichotomous), e.g. toxic/non-toxic, and continuous bioactivity data sets, e.g. [Formula: see text] or [Formula: see text] values. The library bioalerts relies on the RDKit implementation of the circular Morgan fingerprint algorithm to compute chemical substructures, which are derived by considering radial atom neighbourhoods of increasing bond radius. In addition to the derivation of structural alerts, bioalerts provides functionalities for the calculation of unhashed (keyed) Morgan fingerprints, which can be used in predictive bioactivity modelling with the advantage of allowing for a chemically meaningful deconvolution of the chemical space. Finally, bioalerts provides functionalities for the easy visualization of the derived structural alerts.

  15. MyEEW: A Smartphone App for the ShakeAlert System

    Science.gov (United States)

    Strauss, J. A.; Allen, S.; Allen, R. M.; Hellweg, M.

    2015-12-01

    Earthquake Early Warning (EEW) is a system that can provide a few to tens of seconds warning prior to ground shaking at a user's location. The goal and purpose of such a system is to reduce, or minimize, the damage, costs, and casualties resulting from an earthquake. A demonstration earthquake early warning system (ShakeAlert) is undergoing testing in the United States by the UC Berkeley Seismological Laboratory, Caltech, ETH Zurich, University of Washington, the USGS, and beta users in California and the Pacific Northwest. The UC Berkeley Seismological Laboratory has created a smartphone app called MyEEW, which interfaces with the ShakeAlert system to deliver early warnings to individual users. Many critical facilities (transportation, police, and fire) have control rooms, which could run a centralized interface, but our ShakeAlert Beta Testers have also expressed their need for mobile options. This app augments the basic ShakeAlert Java desktop applet by allowing workers off-site (or merely out of hearing range) to be informed of coming hazards. MyEEW receives information from the ShakeAlert system to provide users with real-time information about shaking that is about to happen at their individual location. It includes a map, timer, and earthquake information similar to the Java desktop User Display. The app will also feature educational material to help users craft their own response and resiliency strategies. The app will be open to UC Berkeley Earthquake Research Affiliates members for testing in the near future.

  16. Alerts Analysis and Visualization in Network-based Intrusion Detection Systems

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Dr. Li [University of Tennessee

    2010-08-01

    The alerts produced by network-based intrusion detection systems, e.g. Snort, can be difficult for network administrators to efficiently review and respond to due to the enormous number of alerts generated in a short time frame. This work describes how the visualization of raw IDS alert data assists network administrators in understanding the current state of a network and quickens the process of reviewing and responding to intrusion attempts. The project presented in this work consists of three primary components. The first component provides a visual mapping of the network topology that allows the end-user to easily browse clustered alerts. The second component is based on the flocking behavior of birds such that birds tend to follow other birds with similar behaviors. This component allows the end-user to see the clustering process and provides an efficient means for reviewing alert data. The third component discovers and visualizes patterns of multistage attacks by profiling the attacker s behaviors.

  17. Improving Radiology Workflow with Automated Examination Tracking and Alerts.

    Science.gov (United States)

    Pianykh, Oleg S; Jaworsky, Christina; Shore, M T; Rosenthal, Daniel I

    2017-07-01

    The modern radiology workflow is a production line where imaging examinations pass in sequence through many steps. In busy clinical environments, even a minor delay in any step can propagate through the system and significantly lengthen the examination process. This is particularly true for the tasks delegated to the human operators, who may be distracted or stressed. We have developed an application to track examinations through a critical part of the workflow, from the image-acquisition scanners to the PACS archive. Our application identifies outliers and actively alerts radiology managers about the need to resolve these problems as soon as they happen. In this study, we investigate how this real-time tracking and alerting affected the speed of examination delivery to the radiologist. We demonstrate that active alerting produced a 3-fold reduction of examination-to-PACS delays. Additionally, we discover an overall improvement in examination-to-PACS delivery, evidence that the tracking and alerts instill a culture where timely processing is essential. By providing supervisors with information about exactly where delays emerge in their workflow and alerting the correct staff to take action, applications like ours create more robust radiology workflow with predictable, timely outcomes. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  18. Alertness management in two-person long-haul flight operations

    Science.gov (United States)

    Rosekind, M. R.; Gander, P. H.

    1992-01-01

    Long-haul flight operations involve cumulative sleep loss, circadian disruption, and extended and irregular duty schedules. These factors reduce pilot alertness and performance on the flightdeck. Conceptually and operationally, alertness management in flight operations can be divided into preventive strategies and operational countermeasures. Preventive strategies are utilized prior to a duty period to mitigate or reduce the effects of sleep loss, circadian disruption and fatigue during subsequent flight operations. Operational countermeasures are used during operations as acute techniques for maintaining performance and alertness. Results from previous NASA Ames field studies document the sleep loss and circadian disruption in three-person long-haul flying and illustrate the application of preventive strategies and operational countermeasures. One strategy that can be used in both a preventive and operational manner is strategic napping. The application and effectiveness of strategic napping in long-haul operations will be discussed. Finally, long-haul flying in two-person highly automated aircraft capable of extended range operations will create new challenges to maintaining pilot alertness and performance. Alertness management issues in this flight environment will be explored.

  19. The Acute Effects of Intermittent Light Exposure in the Evening on Alertness and Subsequent Sleep Architecture.

    Science.gov (United States)

    Yang, Minqi; Ma, Ning; Zhu, Yingying; Su, Ying-Chu; Chen, Qingwei; Hsiao, Fan-Chi; Ji, Yanran; Yang, Chien-Ming; Zhou, Guofu

    2018-03-15

    Exposure to bright light is typically intermittent in our daily life. However, the acute effects of intermittent light on alertness and sleep have seldom been explored. To investigate this issue, we employed within-subject design and compared the effects of three light conditions: intermittent bright light (30-min pulse of blue-enriched bright light (~1000 lux, ~6000 K) alternating with 30-min dim normal light (~5 lux, ~3600 K) three times); continuous bright light; and continuous dim light on subjective and objective alertness and subsequent sleep structure. Each light exposure was conducted during the three hours before bedtime. Fifteen healthy volunteers (20 ± 3.4 years; seven males) were scheduled to stay in the sleep laboratory for four separated nights (one for adaptation and the others for the light exposures) with a period of at least one week between nights. The results showed that when compared with dim light, both intermittent light and continuous bright light significantly increased subjective alertness and decreased sleep efficiency (SE) and total sleep time (TST). Intermittent light significantly increased objective alertness than dim light did during the second half of the light-exposure period. Our results suggested that intermittent light was as effective as continuous bright light in their acute effects in enhancing subjective and objective alertness and in negatively impacting subsequent sleep.

  20. The Acute Effects of Intermittent Light Exposure in the Evening on Alertness and Subsequent Sleep Architecture

    Directory of Open Access Journals (Sweden)

    Minqi Yang

    2018-03-01

    Full Text Available Exposure to bright light is typically intermittent in our daily life. However, the acute effects of intermittent light on alertness and sleep have seldom been explored. To investigate this issue, we employed within-subject design and compared the effects of three light conditions: intermittent bright light (30-min pulse of blue-enriched bright light (~1000 lux, ~6000 K alternating with 30-min dim normal light (~5 lux, ~3600 K three times; continuous bright light; and continuous dim light on subjective and objective alertness and subsequent sleep structure. Each light exposure was conducted during the three hours before bedtime. Fifteen healthy volunteers (20 ± 3.4 years; seven males were scheduled to stay in the sleep laboratory for four separated nights (one for adaptation and the others for the light exposures with a period of at least one week between nights. The results showed that when compared with dim light, both intermittent light and continuous bright light significantly increased subjective alertness and decreased sleep efficiency (SE and total sleep time (TST. Intermittent light significantly increased objective alertness than dim light did during the second half of the light-exposure period. Our results suggested that intermittent light was as effective as continuous bright light in their acute effects in enhancing subjective and objective alertness and in negatively impacting subsequent sleep.

  1. A review of human factors principles for the design and implementation of medication safety alerts in clinical information systems

    OpenAIRE

    Phansalkar, Shobha; Edworthy, Judy; Hellier, Elizabeth; Seger, Diane L; Schedlbauer, Angela; Avery, Anthony J; Bates, David W

    2010-01-01

    The objective of this review is to describe the implementation of human factors principles for the design of alerts in clinical information systems. First, we conduct a review of alarm systems to identify human factors principles that are employed in the design and implementation of alerts. Second, we review the medical informatics literature to provide examples of the implementation of human factors principles in current clinical information systems using alerts to provide medication decisio...

  2. E-Alerts: Nuclear science and technology (radiation shielding, protection, and safety). E-mail newsletter

    International Nuclear Information System (INIS)

    1999-01-01

    Topics include: Shielding design, nuclear radiation transport properties of materials, decontamination; Container design and transportation requirements for radioactive materials; and Fallout shelters

  3. Primary Care Providers' Opening of Time-Sensitive Alerts Sent to Commercial Electronic Health Record InBaskets.

    Science.gov (United States)

    Cutrona, Sarah L; Fouayzi, Hassan; Burns, Laura; Sadasivam, Rajani S; Mazor, Kathleen M; Gurwitz, Jerry H; Garber, Lawrence; Sundaresan, Devi; Houston, Thomas K; Field, Terry S

    2017-11-01

    Time-sensitive alerts are among the many types of clinical notifications delivered to physicians' secure InBaskets within commercial electronic health records (EHRs). A delayed alert review can impact patient safety and compromise care. To characterize factors associated with opening of non-interruptive time-sensitive alerts delivered into primary care provider (PCP) InBaskets. We analyzed data for 799 automated alerts. Alerts highlighted actionable medication concerns for older patients post-hospital discharge (2010-2011). These were study-generated alerts sent 3 days post-discharge to InBaskets for 75 PCPs across a multisite healthcare system, and represent a subset of all urgent InBasket notifications. Using EHR access and audit logs to track alert opening, we performed bivariate and multivariate analyses calculating associations between patient characteristics, provider characteristics, contextual factors at the time of alert delivery (number of InBasket notifications, weekday), and alert opening within 24 h. At the time of alert delivery, the PCPs had a median of 69 InBasket notifications and had received a median of 379.8 notifications (IQR 295.0, 492.0) over the prior 7 days. Of the 799 alerts, 47.1% were opened within 24 h. Patients with longer hospital stays (>4 days) were marginally more likely to have alerts opened (OR 1.48 [95% CI 1.00-2.19]). Alerts delivered to PCPs whose InBaskets had a higher number of notifications at the time of alert delivery were significantly less likely to be opened within 24 h (top quartile >157 notifications: OR 0.34 [95% CI 0.18-0.61]; reference bottom quartile ≤42). Alerts delivered on Saturdays were also less likely to be opened within 24 h (OR 0.18 [CI 0.08-0.39]). The number of total InBasket notifications and weekend delivery may impact the opening of time-sensitive EHR alerts. Further study is needed to support safe and effective approaches to care team management of InBasket notifications.

  4. 77 FR 26701 - Review of the Emergency Alert System

    Science.gov (United States)

    2012-05-07

    ..., DC 20554. The complete text of this document also may be purchased from the Commission's copy... variety of software, the former approach would be more prone to the generation of differing, and thus... rely on TTS technologies. Moreover, such a bar would depart from the Commission's original intention to...

  5. Impact-based earthquake alerts with the U.S. Geological Survey's PAGER system: what's next?

    Science.gov (United States)

    Wald, D.J.; Jaiswal, K.S.; Marano, K.D.; Garcia, D.; So, E.; Hearne, M.

    2012-01-01

    In September 2010, the USGS began publicly releasing earthquake alerts for significant earthquakes around the globe based on estimates of potential casualties and economic losses with its Prompt Assessment of Global Earthquakes for Response (PAGER) system. These estimates significantly enhanced the utility of the USGS PAGER system which had been, since 2006, providing estimated population exposures to specific shaking intensities. Quantifying earthquake impacts and communicating estimated losses (and their uncertainties) to the public, the media, humanitarian, and response communities required a new protocol—necessitating the development of an Earthquake Impact Scale—described herein and now deployed with the PAGER system. After two years of PAGER-based impact alerting, we now review operations, hazard calculations, loss models, alerting protocols, and our success rate for recent (2010-2011) events. This review prompts analyses of the strengths, limitations, opportunities, and pressures, allowing clearer definition of future research and development priorities for the PAGER system.

  6. Framework to Define Structure and Boundaries of Complex Health Intervention Systems: The ALERT Project

    DEFF Research Database (Denmark)

    Boriani, Elena; Esposito, Roberto; Frazzoli, Chiara

    2017-01-01

    of a framework with focus on systems and system boundaries of interdisciplinary projects. As an example on how to apply our framework, we analyzed ALERT [an integrated sensors and biosensors’ system (BEST) aimed at monitoring the quality, health, and traceability of the chain of the bovine milk......], a multidisciplinary and interdisciplinary project based on the application of measurable biomarkers at strategic points of the milk chain for improved food security (including safety), human, and ecosystem health (1). In fact, the European food safety framework calls for science-based support to the primary producers......’ mandate for legal, scientific, and ethical responsibility in food supply. Because of its multidisciplinary and interdisciplinary approach involving human, animal, and ecosystem health, ALERT can be considered as a One Health project. Within the ALERT context, we identified the need to take into account...

  7. When endogenous spatial attention improves conscious perception: effects of alerting and bottom-up activation.

    Science.gov (United States)

    Botta, Fabiano; Lupiáñez, Juan; Chica, Ana B

    2014-01-01

    Recent studies have consistently demonstrated that conscious perception interacts with exogenous attentional orienting, but it can be dissociated from endogenous attentional orienting (Chica Lasaponara, et al., 2011; Wyart & Tallon-Baudry, 2008). It has been hypothesized that enhanced conscious processing at exogenously attended locations results from a synergistic action of spatial orienting, bottom-up activation, and phasic alerting induced by the abrupt onset of the exogenous cue (Chica, Lasaponara, et al., 2011). Instead, as endogenous cues need more time to be interpreted, the phasic alerting they produce may have dissipated when the target appears. Furthermore, endogenous cues presumably elicit a weak bottom-up activation at the cued location. Consistent with these hypotheses, we observed that endogenous attention modulated conscious perception, but only when phasic alerting or bottom-up activation was increased. Results are discussed in the context of recent theoretical models of consciousness (Dehaene, Changeux, Naccache, Sackur, & Sergent, 2006). Copyright © 2013 Elsevier Inc. All rights reserved.

  8. Behavioral and Brain Measures of Phasic Alerting Effects on Visual Attention

    DEFF Research Database (Denmark)

    Wiegand, Iris Michaela; Petersen, Anders; Finke, Kathrin

    2017-01-01

    In the present study, we investigated effects of phasic alerting on visual attention in a partial report task, in which half of the displays were preceded by an auditory warning cue. Based on the computational Theory of Visual Attention (TVA), we estimated parameters of spatial and non......-spatial aspects of visual attention and measured event-related lateralizations (ERLs) over visual processing areas. We found that the TVA parameter sensory effectiveness a, which is thought to reflect visual processing capacity, significantly increased with phasic alerting. By contrast, the distribution of visual....... These results suggest that phasic alerting facilitates visual processing in a general, unselective manner and that this effect originates in early stages of visual information processing....

  9. Automated health alerts from Kinect-based in-home gait measurements.

    Science.gov (United States)

    Stone, Erik E; Skubic, Marjorie; Back, Jessica

    2014-01-01

    A method for automatically generating alerts to clinicians in response to changes in in-home gait parameters is investigated. Kinect-based gait measurement systems were installed in apartments in a senior living facility. The systems continuously monitored the walking speed, stride time, and stride length of apartment residents. A framework for modeling uncertainty in the residents' gait parameter estimates, which is critical for robust change detection, is developed; along with an algorithm for detecting changes that may be clinically relevant. Three retrospective case studies, of individuals who had their gait monitored for periods ranging from 12 to 29 months, are presented to illustrate use of the alert method. Evidence suggests that clinicians could be alerted to health changes at an early stage, while they are still small and interventions may be most successful. Additional potential uses are also discussed.

  10. The Common Alerting Protocol (CAP) and Emergency Data Exchange Language (EDXL) - Application in Early Warning Systems for Natural Hazard

    Science.gov (United States)

    Lendholt, Matthias; Hammitzsch, Martin; Wächter, Joachim

    2010-05-01

    The Common Alerting Protocol (CAP) [1] is an XML-based data format for exchanging public warnings and emergencies between alerting technologies. In conjunction with the Emergency Data Exchange Language (EDXL) Distribution Element (-DE) [2] these data formats can be used for warning message dissemination in early warning systems for natural hazards. Application took place in the DEWS (Distance Early Warning System) [3] project where CAP serves as central message format containing both human readable warnings and structured data for automatic processing by message receivers. In particular the spatial reference capabilities are of paramount importance both in CAP and EDXL. Affected areas are addressable via geo codes like HASC (Hierarchical Administrative Subdivision Codes) [4] or UN/LOCODE [5] but also with arbitrary polygons that can be directly generated out of GML [6]. For each affected area standardized criticality values (urgency, severity and certainty) have to be set but also application specific key-value-pairs like estimated time of arrival or maximum inundation height can be specified. This enables - together with multilingualism, message aggregation and message conversion for different dissemination channels - the generation of user-specific tailored warning messages. [1] CAP, http://www.oasis-emergency.org/cap [2] EDXL-DE, http://docs.oasis-open.org/emergency/edxl-de/v1.0/EDXL-DE_Spec_v1.0.pdf [3] DEWS, http://www.dews-online.org [4] HASC, "Administrative Subdivisions of Countries: A Comprehensive World Reference, 1900 Through 1998" ISBN 0-7864-0729-8 [5] UN/LOCODE, http://www.unece.org/cefact/codesfortrade/codes_index.htm [6] GML, http://www.opengeospatial.org/standards/gml

  11. Applying mathematical models to predict resident physician performance and alertness on traditional and novel work schedules.

    Science.gov (United States)

    Klerman, Elizabeth B; Beckett, Scott A; Landrigan, Christopher P

    2016-09-13

    In 2011 the U.S. Accreditation Council for Graduate Medical Education began limiting first year resident physicians (interns) to shifts of ≤16 consecutive hours. Controversy persists regarding the effectiveness of this policy for reducing errors and accidents while promoting education and patient care. Using a mathematical model of the effects of circadian rhythms and length of time awake on objective performance and subjective alertness, we quantitatively compared predictions for traditional intern schedules to those that limit work to ≤ 16 consecutive hours. We simulated two traditional schedules and three novel schedules using the mathematical model. The traditional schedules had extended duration work shifts (≥24 h) with overnight work shifts every second shift (including every third night, Q3) or every third shift (including every fourth night, Q4) night; the novel schedules had two different cross-cover (XC) night team schedules (XC-V1 and XC-V2) and a Rapid Cycle Rotation (RCR) schedule. Predicted objective performance and subjective alertness for each work shift were computed for each individual's schedule within a team and then combined for the team as a whole. Our primary outcome was the amount of time within a work shift during which a team's model-predicted objective performance and subjective alertness were lower than that expected after 16 or 24 h of continuous wake in an otherwise rested individual. The model predicted fewer hours with poor performance and alertness, especially during night-time work hours, for all three novel schedules than for either the traditional Q3 or Q4 schedules. Three proposed schedules that eliminate extended shifts may improve performance and alertness compared with traditional Q3 or Q4 schedules. Predicted times of worse performance and alertness were at night, which is also a time when supervision of trainees is lower. Mathematical modeling provides a quantitative comparison approach with potential to aid

  12. Operator alertness and performance on 8-hour and 12-hour work shifts

    International Nuclear Information System (INIS)

    Baker, T.L.; Campbell, S.S.; Dawson, D.; Moore-Ede, M.

    1989-01-01

    Recently, much attention has been paid to the alertness and performance problems of rotational shiftworkers in the nuclear power industry. Growing awareness of higher rates of human errors and accidents on night shifts and reports of operations personnel falling asleep on the job have contributed to the heightened interest in this subject. The industry is now considering the effects of different shift rotation systems, including evaluation of the most recent of industry trends in shift scheduling-schedules that include 12 hour work shifts. Surveys show that within the past 5 years about 20% of commercially operational nuclear power plants have instituted schedules that use only 12 hour shifts, or schedules using a combination of 8-hour and 12-hour shifts. Many more plants routinely use 12-hour work shifts during plant outages and refueling operations. In response to this growing trend, the NRC has funded research which is a first attempt to compare alertness, operator performance, and sleep-wake patterns in subjects working simulated 8-hour and 12-hour shifts at the Human Alertness Research Center (HARC), located at the Institute of Circadian Physiology in Boston, MA. This paper will describe in greater detail the design of the study, measurement techniques for alertness and sleep, work routine, work task performance measures, and cognitive performance test protocols. It will review the role of circadian factors in human alertness and performance, and discuss previous research findings in this area. It will discuss other variables that are known to influence human alertness in the workplace, such as caffeine, alcohol, and working environment. The physiological basis for shift worker sleep problems will be explained in the context of the ongoing research project at HARC. Finally, the paper presents previous research on shift work and fatigue which may be relevant to a comparison of 8-hour and 12-hour shifts

  13. Feature-based alert correlation in security systems using self organizing maps

    Science.gov (United States)

    Kumar, Munesh; Siddique, Shoaib; Noor, Humera

    2009-04-01

    The security of the networks has been an important concern for any organization. This is especially important for the defense sector as to get unauthorized access to the sensitive information of an organization has been the prime desire for cyber criminals. Many network security techniques like Firewall, VPN Concentrator etc. are deployed at the perimeter of network to deal with attack(s) that occur(s) from exterior of network. But any vulnerability that causes to penetrate the network's perimeter of defense, can exploit the entire network. To deal with such vulnerabilities a system has been evolved with the purpose of generating an alert for any malicious activity triggered against the network and its resources, termed as Intrusion Detection System (IDS). The traditional IDS have still some deficiencies like generating large number of alerts, containing both true and false one etc. By automatically classifying (correlating) various alerts, the high-level analysis of the security status of network can be identified and the job of network security administrator becomes much easier. In this paper we propose to utilize Self Organizing Maps (SOM); an Artificial Neural Network for correlating large amount of logged intrusion alerts based on generic features such as Source/Destination IP Addresses, Port No, Signature ID etc. The different ways in which alerts can be correlated by Artificial Intelligence techniques are also discussed. . We've shown that the strategy described in the paper improves the efficiency of IDS by better correlating the alerts, leading to reduced false positives and increased competence of network administrator.

  14. The Diagnostic Utility of Bact/ALERT and Nested PCR in the Diagnosis of Tuberculous Meningitis.

    Science.gov (United States)

    Sastry, Apurba Sankar; Bhat K, Sandhya; Kumudavathi

    2013-01-01

    The early laboratory diagnosis of Tuberculous Meningitis (TBM) is crucial, to start the antitubercular chemotherapy and to prevent its complications. However, the conventional methods are either less sensitive or time consuming. Hence, the diagnostic potentials of BacT/ALERT and Polymerase Chain Reaction (PCR) was evaluated in this study. The study group comprised of 62 cases and 33 controls. The cases were divided according to Ahuja's criteria into the confirmed (two cases), highly probable (19 cases), probable (26 cases) and the possible (15 cases) subgroups. Ziehl Neelsen's (ZN) and Auramine Phenol (AP) staining, Lowenstein Jensen (LJ) medium culture, BacT/ALERT and nested Polymerase Chain Reaction (PCR) which targeted IS6110 were carried out on all the patients. The sensitivity of the LJ culture was 3.22%. BacT/ALERT showed a sensitivity and a specificity of 25.80% and 100% and those of nested PCR were found to be 40.32% and 96.97% respectively. The mean detection time of growth of the LJ culture was 31.28 days, whereas that of BacT/ALERT was 20.68 days. The contamination rate in the LJ culture and BacT/ALERT were 7.2% and 5.8% respectively. Nested PCR was found to be more sensitive, followed by BacT/ALERT as compared to the LJ culture and smear microscopy. As both false negative and false positive results have been reported for nested PCR, so it should not be used alone as a criterion for initiating or terminating the therapy, but it should be supported by clinical, radiological, cytological and other microbiological findings.

  15. RED Alert – Early warning or detection of global re-emerging infectious disease (RED)

    Energy Technology Data Exchange (ETDEWEB)

    Deshpande, Alina [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-07-13

    This is the PDF of a presentation for a webinar given by Los Alamos National Laboratory (LANL) on the early warning or detection of global re-emerging infectious disease (RED). First, there is an overview of LANL biosurveillance tools. Then, information is given about RED Alert. Next, a demonstration is given of a component prototype. RED Alert is an analysis tool that can provide early warning or detection of the re-emergence of an infectious disease at the global level, but through a local lens.

  16. Phasic alerting increases visual attention capacity in younger but not in older individuals

    DEFF Research Database (Denmark)

    Wiegand, Iris Michaela; Petersen, Anders; Bundesen, Claus

    2017-01-01

    In the present study, we investigated effects of phasic alerting on visual attention in younger and older adults. We modelled parameters of visual attention based on the computational Theory of Visual Attention (TVA) and measured event-related lateralizations (ERLs) in a partial report task, in w...... and attention, which governs the responsiveness to external cues and is critical for general cognitive functioning in aging.......In the present study, we investigated effects of phasic alerting on visual attention in younger and older adults. We modelled parameters of visual attention based on the computational Theory of Visual Attention (TVA) and measured event-related lateralizations (ERLs) in a partial report task...

  17. Detection and Alert of muscle fatigue considering a Surface Electromyography Chaotic Model

    International Nuclear Information System (INIS)

    Herrera, V; Romero, J F; Amestegui, M

    2011-01-01

    This work propose a detection and alert algorithm for muscle fatigue in paraplegic patients undergoing electro-therapy sessions. The procedure is based on a mathematical chaotic model emulating physiological signals and Continuous Wavelet Transform (CWT). The chaotic model developed is based on a logistic map that provides suitable data accomplishing some physiological signal class patterns. The CWT was applied to signals generated by the model and the resulting vector was obtained through Total Wavelet Entropy (TWE). In this sense, the presented work propose a viable and practical alert and detection algorithm for muscle fatigue.

  18. Detection and Alert of muscle fatigue considering a Surface Electromyography Chaotic Model

    Energy Technology Data Exchange (ETDEWEB)

    Herrera, V; Romero, J F [Engineering, Modeling and Applied Social Sciences Center, ABC Federal University, Santo Andr - SP (Brazil); Amestegui, M, E-mail: victoria.herrera@ufabc.edu.br [Engineering Faculty, Electronics Engineering, Universidad Mayor de San Andres, La Paz (Bolivia, Plurinational State of)

    2011-03-01

    This work propose a detection and alert algorithm for muscle fatigue in paraplegic patients undergoing electro-therapy sessions. The procedure is based on a mathematical chaotic model emulating physiological signals and Continuous Wavelet Transform (CWT). The chaotic model developed is based on a logistic map that provides suitable data accomplishing some physiological signal class patterns. The CWT was applied to signals generated by the model and the resulting vector was obtained through Total Wavelet Entropy (TWE). In this sense, the presented work propose a viable and practical alert and detection algorithm for muscle fatigue.

  19. Tattoos: could they be used to advantage as a medical alert in oral and maxillofacial surgery?

    Science.gov (United States)

    Colbert, S D; Brennan, P A

    2017-04-01

    Many publications have addressed the medical complications of tattoos, but to our knowledge there are no reports of their use to alert people in our field of potentially dangerous conditions. We present a new way to inform oral and maxillofacial colleagues about patients with a history of malignant hyperthermia (or any other life-threatening medical problem) and discuss the potential advantages and disadvantages of medical alert tattoos. Copyright © 2016 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. The Early Awareness and Alert System in Sweden: History and Current Status

    Directory of Open Access Journals (Sweden)

    Irene Eriksson

    2017-10-01

    Full Text Available Introduction: Over the past decades, early awareness and alert (EAA activities and systems have gained importance and become a key early health technology assessment (HTA tool. While a pioneer in HTA, Sweden had no national level EAA activities until 2010. We describe the evolution and current status of the Swedish EAA System.Methods: This was a historical analysis based on the knowledge and experience of the authors supplemented by a targeted review of published and gray literature as well as documents relating to EAA activities in Sweden. Key milestones and a description of the current state of the Swedish EAA System is presented.Results: Initiatives to establish a system for the identification and assessment of emerging health technologies in Sweden date back to the 1980s. In the 1990s, the Swedish Agency for HTA and Assessment of Social Services (SBU supported the development of EuroScan as one of its founder members. In the mid-2000s, an independent regional initiative, driven by the Stockholm County Drug and Therapeutics Committee, resulted in the establishment of a regional horizon scanning function. By 2009, this work had expanded to a collaboration between the four biggest counties in Sweden. The following year it was further expanded to the national level and since then the Swedish EAA System has been carrying out identification, filtration and prioritization of new medicines, early assessment of the prioritized medicines, and dissemination of information. In 2015, the EAA System was incorporated into the Swedish national process for managed introduction and follow-up of new medicines. Outputs from the EAA System are now used to select new medicines for inclusion in this process.Conclusions: The Swedish EAA System started as a regional initiative and rapidly grew to become a national level activity. An important feature of the system today is its complete integration into the national process for managed introduction and follow-up of

  1. Stimulated reporting: the impact of US food and drug administration-issued alerts on the adverse event reporting system (FAERS).

    Science.gov (United States)

    Hoffman, Keith B; Demakas, Andrea R; Dimbil, Mo; Tatonetti, Nicholas P; Erdman, Colin B

    2014-11-01

    The US Food and Drug Administration (FDA) uses the Adverse Event Reporting System (FAERS) to support post-marketing safety surveillance programs. Currently, almost one million case reports are submitted to FAERS each year, making it a vast repository of drug safety information. Sometimes cited as a limitation of FAERS, however, is the assumption that "stimulated reporting" of adverse events (AEs) occurs in response to warnings, alerts, and label changes that are issued by the FDA. To determine the extent of "stimulated reporting" in the modern-day FAERS database. One hundred drugs approved by the FDA between 2001 and 2010 were included in this analysis. FDA alerts were obtained by a comprehensive search of the FDA's MedWatch and main websites. Publicly available FAERS data were used to assess the "primary suspect" AE reporting pattern for up to four quarters before, and after, the issuance of an FDA alert. A few drugs did demonstrate "stimulated reporting" trends. A majority of the drugs, however, showed little evidence for significant reporting changes associated with the issuance of alerts. When we compared the percentage changes in reporting after an FDA alert with those after a sham "control alert", the overall reporting trends appeared to be quite similar. Of 100 drugs analyzed for short-term reporting trends, 21 real alerts and 25 sham alerts demonstrated an increase (greater than or equal to 1 %) in reporting. The long-term analysis of 91 drugs showed that 24 real alerts and 28 sham alerts demonstrated a greater than or equal to 1 % increase. Our results suggest that most of modern day FAERS reporting is not significantly affected by the issuance of FDA alerts.

  2. Taking up national safety alerts to improve patient safety in hospitals: The perspective of healthcare quality and risk managers.

    Science.gov (United States)

    Pfeiffer, Yvonne; Schwappach, David

    2016-01-01

    National safety alert systems publish relevant information to improve patient safety in hospitals. However, the information has to be transformed into local action to have an effect on patient safety. We studied three research questions: How do Swiss healthcare quality and risk managers (qm/rm(1)) see their own role in learning from safety alerts issued by the Swiss national voluntary reporting and analysis system? What are their attitudes towards and evaluations of the alerts, and which types of improvement actions were fostered by the safety alerts? A survey was developed and applied to Swiss healthcare risk and quality managers, with a response rate of 39 % (n=116). Descriptive statistics are presented. The qm/rm disseminate and communicate with a broad variety of professional groups about the alerts. While most respondents felt that they should know the alerts and their contents, only a part of them felt responsible for driving organizational change based on the recommendations. However, most respondents used safety alerts to back up their own patient safety goals. The alerts were evaluated positively on various dimensions such as usefulness and were considered as standards of good practice by the majority of the respondents. A range of organizational responses was applied, with disseminating information being the most common. An active role is related to using safety alerts for backing up own patient safety goals. To support an active role of qm/rm in their hospital's learning from safety alerts, appropriate organizational structures should be developed. Furthermore, they could be given special information or training to act as an information hub on the issues discussed in the alerts. Copyright © 2016. Published by Elsevier GmbH.

  3. A process-based model for the definition of hydrological alert systems in landslide risk mitigation

    Directory of Open Access Journals (Sweden)

    M. Floris

    2012-11-01

    Full Text Available The definition of hydrological alert systems for rainfall-induced landslides is strongly related to a deep knowledge of the geological and geomorphological features of the territory. Climatic conditions, spatial and temporal evolution of the phenomena and characterization of landslide triggering, together with propagation mechanisms, are the key elements to be considered. Critical steps for the development of the systems consist of the identification of the hydrological variable related to landslide triggering and of the minimum rainfall threshold for landslide occurrence.

    In this paper we report the results from a process-based model to define a hydrological alert system for the Val di Maso Landslide, located in the northeastern Italian Alps and included in the Vicenza Province (Veneto region, NE Italy. The instability occurred in November 2010, due to an exceptional rainfall event that hit the Vicenza Province and the entire NE Italy. Up to 500 mm in 3-day cumulated rainfall generated large flood conditions and triggered hundreds of landslides. During the flood, the Soil Protection Division of the Vicenza Province received more than 500 warnings of instability phenomena. The complexity of the event and the high level of risk to infrastructure and private buildings are the main reasons for deepening the specific phenomenon occurred at Val di Maso.

    Empirical and physically-based models have been used to identify the minimum rainfall threshold for the occurrence of instability phenomena in the crown area of Val di Maso landslide, where a retrogressive evolution by multiple rotational slides is expected. Empirical models helped in the identification and in the evaluation of recurrence of critical rainfall events, while physically-based modelling was essential to verify the effects on the slope stability of determined rainfall depths. Empirical relationships between rainfall and landslide consist of the calculation of rainfall

  4. Development of case-based medication alerting and recommender system: a new approach to prevention for medication error.

    Science.gov (United States)

    Miyo, Kengo; Nittami, Yuki S; Kitagawa, Yoichiro; Ohe, Kazuhiko

    2007-01-01

    The purpose of this study was to develop a new alerting and recommender system for preventing medication errors. In recent years, alerting systems have been widely implemented, but because these systems apply a same static threshold for all patients in all cases, they produce excessive alerts and subject physicians to "alert fatigue". We believe that the most commonly-written prescription for a patient's status is the safest one. From this standpoint, we developed a real-time case-based medication alerting and recommender system linked to a database of past prescriptions. When a physician issues his or her prescription, our system dynamically compares it with past ones for similar patients in the database. An analysis of the 10 most frequently-used drugs in the University of Tokyo Hospital revealed that our system reduced the number of false alerts compared to the traditional static alert method. Our system contributes to the creation of alerts that are appropriate for patients' clinical conditions and based on physicians' empirical discretion.

  5. Catch the wave! Time-window sequential analysis of alertness stimulation in individuals with profound intellectual and multiple disabilities

    NARCIS (Netherlands)

    Munde, V. S.; Vlaskamp, C.; Maes, B.; Ruijssenaars, A. J. J. M.

    BackgroundWhile optimally activities are provided at those moments when the individual with profound intellectual and multiple disabilities (PIMD) is focused on the environment' or alert', detailed information about the impact that the design and timing of the activity has on alertness is lacking.

  6. Aircraft Alerting Systems Standardization Study. Phase IV. Accident Implications on Systems Design.

    Science.gov (United States)

    1982-06-01

    computing and processing to assimilate and process status informa- 5 tion using...provided with capabilities in computing and processing , sensing, interfacing, and controlling and displaying. 17 o Computing and Processing - Algorithms...alerting system to perform a flight status monitor function would require additional sensinq, computing and processing , interfacing, and controlling

  7. Earthquake early Warning ShakeAlert system: West coast wide production prototype

    Science.gov (United States)

    Kohler, Monica D.; Cochran, Elizabeth S.; Given, Douglas; Guiwits, Stephen; Neuhauser, Doug; Hensen, Ivan; Hartog, Renate; Bodin, Paul; Kress, Victor; Thompson, Stephen; Felizardo, Claude; Brody, Jeff; Bhadha, Rayo; Schwarz, Stan

    2017-01-01

    Earthquake early warning (EEW) is an application of seismological science that can give people, as well as mechanical and electrical systems, up to tens of seconds to take protective actions before peak earthquake shaking arrives at a location. Since 2006, the U.S. Geological Survey has been working in collaboration with several partners to develop EEW for the United States. The goal is to create and operate an EEW system, called ShakeAlert, for the highest risk areas of the United States, starting with the West Coast states of California, Oregon, and Washington. In early 2016, the Production Prototype v.1.0 was established for California; then, in early 2017, v.1.2 was established for the West Coast, with earthquake notifications being distributed to a group of beta users in California, Oregon, and Washington. The new ShakeAlert Production Prototype was an outgrowth from an earlier demonstration EEW system that began sending test notifications to selected users in California in January 2012. ShakeAlert leverages the considerable physical, technical, and organizational earthquake monitoring infrastructure of the Advanced National Seismic System, a nationwide federation of cooperating seismic networks. When fully implemented, the ShakeAlert system may reduce damage and injury caused by large earthquakes, improve the nation’s resilience, and speed recovery.

  8. Correlating intrusion detection alerts on bot malware infections using neural network

    DEFF Research Database (Denmark)

    Kidmose, Egon; Stevanovic, Matija; Pedersen, Jens Myrup

    2016-01-01

    Millions of computers are infected with bot malware, form botnets and enable botmaster to perform malicious and criminal activities. Intrusion Detection Systems are deployed to detect infections, but they raise many correlated alerts for each infection, requiring a large manual investigation effort...

  9. The Effect of Happiness and Sadness on Alerting, Orienting, and Executive Attention

    Science.gov (United States)

    Finucane, Anne M.; Whiteman, Martha C.; Power, Mick J.

    2010-01-01

    Objective: According to the attention network approach, attention is best understood in terms of three functionally and neuroanatomically distinct networks--alerting, orienting, and executive attention. An important question is whether the experience of emotion differentially influences the efficiency of these networks. Method: This study examines…

  10. Evidence behind FDA alerts for drugs with adverse cardiovascular effects: implications for clinical practice.

    Science.gov (United States)

    Rackham, Daniel M; C Herink, Megan; Stevens, Ian G; Cardoza, Natalie M; Singh, Harleen

    2014-01-01

    The U.S. Food and Drug Administration (FDA) periodically publishes Drug Safety Communications and Drug Alerts notifying health care practitioners and the general public of important information regarding drug therapies following FDA approval. These alerts can result in both positive and negative effects on patient care. Most clinical trials are not designed to detect long-term safety end points, and postmarketing surveillance along with patient reported events are often instrumental in signaling the potential harmful effect of a drug. Recently, many cardiovascular (CV) safety announcements have been released for FDA-approved drugs. Because a premature warning could discourage a much needed treatment or prompt a sudden discontinuation, it is essential to evaluate the evidence supporting these FDA alerts to provide effective patient care and to avoid unwarranted changes in therapy. Conversely, paying attention to these warnings in cases involving high-risk patients can prevent adverse effects and litigation. This article reviews the evidence behind recent FDA alerts for drugs with adverse CV effects and discusses the clinical practice implications. © 2013 Pharmacotherapy Publications, Inc.

  11. Behavioral and Brain Measures of Phasic Alerting Effects on Visual Attention.

    Science.gov (United States)

    Wiegand, Iris; Petersen, Anders; Finke, Kathrin; Bundesen, Claus; Lansner, Jon; Habekost, Thomas

    2017-01-01

    In the present study, we investigated effects of phasic alerting on visual attention in a partial report task, in which half of the displays were preceded by an auditory warning cue. Based on the computational Theory of Visual Attention (TVA), we estimated parameters of spatial and non-spatial aspects of visual attention and measured event-related lateralizations (ERLs) over visual processing areas. We found that the TVA parameter sensory effectiveness a , which is thought to reflect visual processing capacity, significantly increased with phasic alerting. By contrast, the distribution of visual processing resources according to task relevance and spatial position, as quantified in parameters top-down control α and spatial bias w index , was not modulated by phasic alerting. On the electrophysiological level, the latencies of ERLs in response to the task displays were reduced following the warning cue. These results suggest that phasic alerting facilitates visual processing in a general, unselective manner and that this effect originates in early stages of visual information processing.

  12. Impact of Entrepreneurship Training on Entrepreneurial Efficacy and Alertness among Adolescent Youth

    Directory of Open Access Journals (Sweden)

    Moon-Ho Ringo Ho

    2018-03-01

    Full Text Available Our study focuses on the impact of systematic entrepreneurship training comprising both active and passive learning activities on entrepreneurial alertness and efficacy among adolescent youth. Reports from a two-wave online survey among 328 students from five secondary schools (aged 13–16 years; 34.8% male and 65.2% female reveal that those who went through entrepreneurship training (treatment group, N = 142 had significantly higher entrepreneurial alertness and efficacy levels compared to those who did not go through training (control group, N = 186. We also find that even with gender effects accounted for, the higher entrepreneurial alertness and efficacy levels in the treatment group are due in part to both passive and active/hands-on elements of the program. Our study offers direct evidence that conducting entrepreneurship training programs among secondary school students could be an effective means to enhance entrepreneurial competencies among the youth. Specifically, our findings highlight the value of entrepreneurial training in improving age-appropriate competencies of entrepreneurial alertness and efficacy.

  13. Visual perception affected by motivation and alertness controlled by a noninvasive brain-computer interface.

    Science.gov (United States)

    Maksimenko, Vladimir A; Runnova, Anastasia E; Zhuravlev, Maksim O; Makarov, Vladimir V; Nedayvozov, Vladimir; Grubov, Vadim V; Pchelintceva, Svetlana V; Hramov, Alexander E; Pisarchik, Alexander N

    2017-01-01

    The influence of motivation and alertness on brain activity associated with visual perception was studied experimentally using the Necker cube, which ambiguity was controlled by the contrast of its ribs. The wavelet analysis of recorded multichannel electroencephalograms (EEG) allowed us to distinguish two different scenarios while the brain processed the ambiguous stimulus. The first scenario is characterized by a particular destruction of alpha rhythm (8-12 Hz) with a simultaneous increase in beta-wave activity (20-30 Hz), whereas in the second scenario, the beta rhythm is not well pronounced while the alpha-wave energy remains unchanged. The experiments were carried out with a group of financially motivated subjects and another group of unpaid volunteers. It was found that the first scenario occurred mainly in the motivated group. This can be explained by the increased alertness of the motivated subjects. The prevalence of the first scenario was also observed in a group of subjects to whom images with higher ambiguity were presented. We believe that the revealed scenarios can occur not only during the perception of bistable images, but also in other perceptual tasks requiring decision making. The obtained results may have important applications for monitoring and controlling human alertness in situations which need substantial attention. On the base of the obtained results we built a brain-computer interface to estimate and control the degree of alertness in real time.

  14. USGS earthquake hazards program (EHP) GPS use case : earthquake early warning (EEW) and shake alert

    Science.gov (United States)

    2017-03-30

    GPS Adjacent Band Workshop VI RTCA Inc., Washington D.C., 30 March 2017. USGS GPS receiver use case - Real-Time GPS for EEW -Continued: CRITICAL EFFECT - The GNSS component of the Shake Alert system augments the inertial sensors and is especial...

  15. Determining alertness in individuals with profound intellectual and multiple disabilities : the reliability of an observation list

    NARCIS (Netherlands)

    Munde, V.S.; Vlaskamp, C.; Ruijssenaars, A.J.J.M.; Nakken, H.

    In the support of individuals with profound intellectual and multiple disabilities (PIMD), assessing the level of alertness is a recurring issue for parents and other direct support persons. Although observations show clear advantages above and beyond other assessment methods, there are problems

  16. Enrichment of true positives from structural alerts through the use of novel atomic fragment based descriptors

    DEFF Research Database (Denmark)

    Long, A.; Rydberg, Patrik

    2013-01-01

    To enhance the discrimination rate for methods applying structural alerts and biotransformation rules in the prediction of toxicity and drug metabolism we have developed a set of novel fragment based atomic descriptors. These atomic descriptors encode the properties of the fragments separating an...

  17. 76 FR 30366 - Draft Alert Entitled “Preventing Occupational Respiratory Disease From Dampness in Office...

    Science.gov (United States)

    2011-05-25

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention [Docket Number NIOSH-238] Draft Alert Entitled ``Preventing Occupational Respiratory Disease From Dampness in Office... Institute for Occupational Safety and Health, Centers for Disease Control and Prevention. [FR Doc. 2011...

  18. Design and implementation of the UFFO burst alert and trigger telescope

    DEFF Research Database (Denmark)

    Kim, J.E.; Ahmad, S.; Barrillon, P.

    2012-01-01

    The Ultra Fast Flash Observatory pathfinder (UFFO-p) is a telescope system designed for the detection of the prompt optical/UV photons from Gamma-Ray Bursts (GRBs), and it will be launched onboard the Lomonosov spacecraft in 2012. The UFFO-p consists of two instruments: the UFFO Burst Alert and T...

  19. Optical flow and driver's kinematics analysis for state of alert sensing.

    Science.gov (United States)

    Jiménez-Pinto, Javier; Torres-Torriti, Miguel

    2013-03-28

    Road accident statistics from different countries show that a significant number of accidents occur due to driver's fatigue and lack of awareness to traffic conditions. In particular, about 60% of the accidents in which long haul truck and bus drivers are involved are attributed to drowsiness and fatigue. It is thus fundamental to improve non-invasive systems for sensing a driver's state of alert. One of the main challenges to correctly resolve the state of alert is measuring the percentage of eyelid closure over time (PERCLOS), despite the driver's head and body movements. In this paper, we propose a technique that involves optical flow and driver's kinematics analysis to improve the robustness of the driver's alert state measurement under pose changes using a single camera with near-infrared illumination. The proposed approach infers and keeps track of the driver's pose in 3D space in order to ensure that eyes can be located correctly, even after periods of partial occlusion, for example, when the driver stares away from the camera. Our experiments show the effectiveness of the approach with a correct eyes detection rate of 99.41%, on average. The results obtained with the proposed approach in an experiment involving fifteen persons under different levels of sleep deprivation also confirm the discriminability of the fatigue levels. In addition to the measurement of fatigue and drowsiness, the pose tracking capability of the proposed approach has potential applications in distraction assessment and alerting of machine operators.

  20. Non-visual biological effects of light on human cognition, alertness, and mood

    Science.gov (United States)

    Li, Huaye; Wang, Huihui; Shen, Junfei; Sun, Peng; Xie, Ting; Zhang, Siman; Zheng, Zhenrong

    2017-09-01

    Light exerts non-visual effects on a wide range of biological functions and behavior apart from the visual effect. Light can regulate human circadian rhythms, like the secretion of melatonin and cortisol. Light also has influence on body's physiological parameters, such as blood pressure, heart rate and body temperature. However, human cognitive performance, alertness and mood under different lighting conditions have not been considered thoroughly especially for the complicated visual task like surgical operating procedure. In this paper, an experiment was conducted to investigate the cognition, alertness and mood of healthy participants in a simulated operating room (OR) in the hospital. A LED surgical lamp was used as the light source, which is mixed by three color LEDs (amber, green and blue). The surgical lamp is flexible on both spectrum and intensity. Exposed to different light settings, which are varied from color temperature and luminance, participants were asked to take psychomotor vigilance task (PVT) for alertness measurement, alphabet test for cognitive performance measurement, positive and negative affect schedule (PANAS) for mood measurement. The result showed the participants' cognitive performance, alertness and mood are related to the color temperature and luminance of the LED light. This research will have a guidance for the surgical lighting environment, which can not only enhance doctors' efficiency during the operations, but also create a positive and peaceful surgical lighting environment.

  1. An Investigation of Alerting and Prioritization Criteria for Sense and Avoid (SAA)

    Science.gov (United States)

    2013-10-01

    TECHNICAL REPORT RDMR-TM-13-01 AN INVESTIGATION OF ALERTING AND PRIORITIZATION CRITERIA FOR SENSE AND AVOID ( SAA ...OFFICIAL ENDORSEMENT OR APPROVAL OF THE USE OF SUCH COMMERCIAL HARDWARE OR SOFTWARE . i/ii (Blank) REPORT DOCUMENTATION PAGE Form Approved...burden to Washington Headquarters Services , Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington

  2. Visual perception affected by motivation and alertness controlled by a noninvasive brain-computer interface.

    Directory of Open Access Journals (Sweden)

    Vladimir A Maksimenko

    Full Text Available The influence of motivation and alertness on brain activity associated with visual perception was studied experimentally using the Necker cube, which ambiguity was controlled by the contrast of its ribs. The wavelet analysis of recorded multichannel electroencephalograms (EEG allowed us to distinguish two different scenarios while the brain processed the ambiguous stimulus. The first scenario is characterized by a particular destruction of alpha rhythm (8-12 Hz with a simultaneous increase in beta-wave activity (20-30 Hz, whereas in the second scenario, the beta rhythm is not well pronounced while the alpha-wave energy remains unchanged. The experiments were carried out with a group of financially motivated subjects and another group of unpaid volunteers. It was found that the first scenario occurred mainly in the motivated group. This can be explained by the increased alertness of the motivated subjects. The prevalence of the first scenario was also observed in a group of subjects to whom images with higher ambiguity were presented. We believe that the revealed scenarios can occur not only during the perception of bistable images, but also in other perceptual tasks requiring decision making. The obtained results may have important applications for monitoring and controlling human alertness in situations which need substantial attention. On the base of the obtained results we built a brain-computer interface to estimate and control the degree of alertness in real time.

  3. Machine-learning-based Brokers for Real-time Classification of the LSST Alert Stream

    Science.gov (United States)

    Narayan, Gautham; Zaidi, Tayeb; Soraisam, Monika D.; Wang, Zhe; Lochner, Michelle; Matheson, Thomas; Saha, Abhijit; Yang, Shuo; Zhao, Zhenge; Kececioglu, John; Scheidegger, Carlos; Snodgrass, Richard T.; Axelrod, Tim; Jenness, Tim; Maier, Robert S.; Ridgway, Stephen T.; Seaman, Robert L.; Evans, Eric Michael; Singh, Navdeep; Taylor, Clark; Toeniskoetter, Jackson; Welch, Eric; Zhu, Songzhe; The ANTARES Collaboration

    2018-05-01

    The unprecedented volume and rate of transient events that will be discovered by the Large Synoptic Survey Telescope (LSST) demand that the astronomical community update its follow-up paradigm. Alert-brokers—automated software system to sift through, characterize, annotate, and prioritize events for follow-up—will be critical tools for managing alert streams in the LSST era. The Arizona-NOAO Temporal Analysis and Response to Events System (ANTARES) is one such broker. In this work, we develop a machine learning pipeline to characterize and classify variable and transient sources only using the available multiband optical photometry. We describe three illustrative stages of the pipeline, serving the three goals of early, intermediate, and retrospective classification of alerts. The first takes the form of variable versus transient categorization, the second a multiclass typing of the combined variable and transient data set, and the third a purity-driven subtyping of a transient class. Although several similar algorithms have proven themselves in simulations, we validate their performance on real observations for the first time. We quantitatively evaluate our pipeline on sparse, unevenly sampled, heteroskedastic data from various existing observational campaigns, and demonstrate very competitive classification performance. We describe our progress toward adapting the pipeline developed in this work into a real-time broker working on live alert streams from time-domain surveys.

  4. Communication of Unexpected and Significant Findings on Chest Radiographs With an Automated PACS Alert System.

    LENUS (Irish Health Repository)

    Hayes, Sara A

    2014-08-01

    An integral part of realizing the enormous potential of imaging in patient care is close communication between radiologists and referring physicians. One key element of this process is the communication of unexpected significant findings. The authors examined the performance of a PACS-based alert system in the appropriate communication of reports containing unexpected significant findings to referring physicians.

  5. Evaluation of the alert line of partogram in recognizing the need for neonatal resuscitation

    Directory of Open Access Journals (Sweden)

    Nahid Bolbol-Haghighi

    2015-01-01

    Conclusions: In mothers who had normal vaginal delivery, with normal fetal heart rate, and with no oxytocin administration or omniotomy, the alert line showed appropriate sensitivity, specificity, and negative prediction value. So, it can assist in predicting the necessity of action for neonatal resuscitation 20–30 s after delivery.

  6. Impact Research Report and Site Summaries for Project ALERT. Workplace Education.

    Science.gov (United States)

    Brandenburg, Dale C.

    In order to evaluate the Project ALERT (Adult Literacy Enhanced & Redefined through Training) Workplace Literacy Project, data were collected to gauge the impact of the program on individual participants, the organizations in which they were employed, and to provide the use of whole language and multimedia techniques in workplace literacy…

  7. Generating Artificial Snort Alerts and Implementing SELK: The Snort-Elasticsearch-Logstash-Kibana Stack

    Science.gov (United States)

    2017-09-01

    classification system with 38 classifications for alerts. These include things such as “trojan- activity”, “shellcode-detect”, “denial-of-service...Abbreviations, and Acronyms ARL US Army Research Laboratory CIDR classless inter-domain routing IP Internet Protocol NIDS network intrusion

  8. Characterizing Tropical Forest Cover Loss Using Dense Sentinel-1 Data and Active Fire Alerts

    NARCIS (Netherlands)

    Reiche, Johannes; Verhoeven, Rob; Verbesselt, Jan; Hamunyela, Eliakim; Wielaard, Niels; Herold, Martin

    2018-01-01

    Fire use for land management is widespread in natural tropical and plantation forests, causing major environmental and economic damage. Recent studies combining active fire alerts with annual forest-cover loss information identified fire-related forest-cover loss areas well, but do not provide

  9. Global Trade Alert (GTA) - Phase II: Year 2 - Monitoring and Analysis ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Global Trade Alert (GTA), funded under project 105821, endeavors to provide information in real time on national measures that are likely to discriminate against foreign commerce. Building on inputs supplied by regional institutional partners and international experts, suspected protectionist measures are identified, ...

  10. ATLANTIDES: An Architecture for Alert Verification in Network Intrusion Detection Systems

    NARCIS (Netherlands)

    Bolzoni, D.; Crispo, Bruno; Etalle, Sandro

    2007-01-01

    We present an architecture designed for alert verification (i.e., to reduce false positives) in network intrusion-detection systems. Our technique is based on a systematic (and automatic) anomaly-based analysis of the system output, which provides useful context information regarding the network

  11. 47 CFR 80.335 - Procedures for canceling false distress alerts.

    Science.gov (United States)

    2010-10-01

    ... message to “All stations” giving the ship's name, call sign or registration number, and MMSI, and cancel... on 2182 kHz; and (4) Transmit a broadcast message to “All stations” giving the ship's name, call sign... name, call sign or registration number, and MMSI, and cancel the false distress alert frequency in each...

  12. Drug safety alerts of pharmacovigilance programme of India: A scope for targeted spontaneous reporting in India

    Directory of Open Access Journals (Sweden)

    Prasad Thota

    2018-01-01

    Conclusion: In India, spontaneous reporting of ADRs existed since 1998 under passive surveillance method, but there is an urgent need to initiate TSR, which is a complementary method to spontaneous reporting on these drug safety alerts for further regulatory action by Central Drugs Standard Control Organization.

  13. Correlated colour temperature of morning light influences alertness and body temperature.

    Science.gov (United States)

    Te Kulve, Marije; Schlangen, Luc; Schellen, Lisje; Souman, Jan L; van Marken Lichtenbelt, Wouter

    2018-03-01

    Though several studies have reported human alertness to be affected by the intensity and spectral composition of ambient light, the mechanism behind this effect is still largely unclear, especially for daytime exposure. Alerting effects of nocturnal light exposure are correlated with melatonin suppression, but melatonin levels are generally low during the day. The aim of this study was to explore the alerting effect of light in the morning for different correlated colour temperature (CCT) values, as well as its interaction with ambient temperature. Body temperature and perceived comfort were included in the study as possible mediating factors. In a randomized crossover design, 16 healthy females participated in two sessions, once under 2700K and once under 6500K light (both 55lx). Each session consisted of a baseline, a cool, a neutral and a warm thermal environment. Alertness as measured in a reaction time task was lower for the 6500K exposure, while subjective sleepiness was not affected by CCT. Also, core body temperature was higher under 6500K. Skin temperature parameters and perceived comfort were positively correlated with subjective sleepiness. Reaction time correlated with heat loss, but this association did not explain why the reaction time was improved for 2700K. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Radar-based alert system to operate a sewerage network: relevance and operational effectiveness after several years of use.

    Science.gov (United States)

    Faure, D; Payrastre, O; Auchet, P

    2005-01-01

    Since January 2000, the sewerage network of a very urbanised catchment area in the Greater Nancy Urban Community has been operated according to the alarms generated in real time by a storm alert system using weather radar data. This alert system is based on an automatic identification of intense rain cells in the radar images. This paper presents the characteristics of this alert system and synthesises the main results of two complementary studies realised in 2002 in order to estimate the relevance and the operational effectiveness of the alert system. The first study consisted in an off-line analysis of almost 50,000 intense rain cells detected in four years of historical radar data. The second study was an analysis of the experience feedback after two years of operational use of this alert system. The results of these studies are discussed in function of the initial operational objectives.

  15. Earthquake Early Warning ShakeAlert System: Testing and certification platform

    Science.gov (United States)

    Cochran, Elizabeth S.; Kohler, Monica D.; Given, Douglas; Guiwits, Stephen; Andrews, Jennifer; Meier, Men-Andrin; Ahmad, Mohammad; Henson, Ivan; Hartog, Renate; Smith, Deborah

    2017-01-01

    Earthquake early warning systems provide warnings to end users of incoming moderate to strong ground shaking from earthquakes. An earthquake early warning system, ShakeAlert, is providing alerts to beta end users in the western United States, specifically California, Oregon, and Washington. An essential aspect of the earthquake early warning system is the development of a framework to test modifications to code to ensure functionality and assess performance. In 2016, a Testing and Certification Platform (TCP) was included in the development of the Production Prototype version of ShakeAlert. The purpose of the TCP is to evaluate the robustness of candidate code that is proposed for deployment on ShakeAlert Production Prototype servers. TCP consists of two main components: a real‐time in situ test that replicates the real‐time production system and an offline playback system to replay test suites. The real‐time tests of system performance assess code optimization and stability. The offline tests comprise a stress test of candidate code to assess if the code is production ready. The test suite includes over 120 events including local, regional, and teleseismic historic earthquakes, recentering and calibration events, and other anomalous and potentially problematic signals. Two assessments of alert performance are conducted. First, point‐source assessments are undertaken to compare magnitude, epicentral location, and origin time with the Advanced National Seismic System Comprehensive Catalog, as well as to evaluate alert latency. Second, we describe assessment of the quality of ground‐motion predictions at end‐user sites by comparing predicted shaking intensities to ShakeMaps for historic events and implement a threshold‐based approach that assesses how often end users initiate the appropriate action, based on their ground‐shaking threshold. TCP has been developed to be a convenient streamlined procedure for objectively testing algorithms, and it has

  16. Do family physicians retrieve synopses of clinical research previously read as email alerts?

    Science.gov (United States)

    Grad, Roland; Pluye, Pierre; Johnson-Lafleur, Janique; Granikov, Vera; Shulha, Michael; Bartlett, Gillian; Marlow, Bernard

    2011-11-30

    A synopsis of new clinical research highlights important aspects of one study in a brief structured format. When delivered as email alerts, synopses enable clinicians to become aware of new developments relevant for practice. Once read, a synopsis can become a known item of clinical information. In time-pressured situations, remembering a known item may facilitate information retrieval by the clinician. However, exactly how synopses first delivered as email alerts influence retrieval at some later time is not known. We examined searches for clinical information in which a synopsis previously read as an email alert was retrieved (defined as a dyad). Our study objectives were to (1) examine whether family physicians retrieved synopses they previously read as email alerts and then to (2) explore whether family physicians purposefully retrieved these synopses. We conducted a mixed-methods study in which a qualitative multiple case study explored the retrieval of email alerts within a prospective longitudinal cohort of practicing family physicians. Reading of research-based synopses was tracked in two contexts: (1) push, meaning to read on email and (2) pull, meaning to read after retrieval from one electronic knowledge resource. Dyads, defined as synopses first read as email alerts and subsequently retrieved in a search of a knowledge resource, were prospectively identified. Participants were interviewed about all of their dyads. Outcomes were the total number of dyads and their type. Over a period of 341 days, 194 unique synopses delivered to 41 participants resulted in 4937 synopsis readings. In all, 1205 synopses were retrieved over an average of 320 days. Of the 1205 retrieved synopses, 21 (1.7%) were dyads made by 17 family physicians. Of the 1205 retrieved synopses, 6 (0.5%) were known item type dyads. However, dyads also occurred serendipitously. In the single knowledge resource we studied, email alerts containing research-based synopses were rarely retrieved

  17. A comparison of blue light and caffeine effects on cognitive function and alertness in humans.

    Science.gov (United States)

    Beaven, C Martyn; Ekström, Johan

    2013-01-01

    The alerting effects of both caffeine and short wavelength (blue) light have been consistently reported. The ability of blue light to enhance alertness and cognitive function via non-image forming neuropathways have been suggested as a non-pharmacological countermeasure for drowsiness across a range of occupational settings. Here we compare and contrast the alerting and psychomotor effects of 240 mg of caffeine and a 1-h dose of ~40 lx blue light in a non-athletic population. Twenty-one healthy subjects performed a computer-based psychomotor vigilance test before and after each of four randomly assigned trial conditions performed on different days: white light/placebo; white light/240 mg caffeine; blue light/placebo; blue light/240 mg caffeine. The Karolinska Sleepiness Scale was used to assess subjective measures of alertness. Both the caffeine only and blue light only conditions enhanced accuracy in a visual reaction test requiring a decision and an additive effect was observed with respect to the fastest reaction times. However, in a test of executive function, where a distraction was included, caffeine exerted a negative effect on accuracy. Furthermore, the blue light only condition consistently outperformed caffeine when both congruent and incongruent distractions were presented. The visual reactions in the absence of a decision or distraction were also enhanced in the blue light only condition and this effect was most prominent in the blue-eyed participants. Overall, blue light and caffeine demonstrated distinct effects on aspects of psychomotor function and have the potential to positively influence a range of settings where cognitive function and alertness are important. Specifically, despite the widespread use of caffeine in competitive sporting environments, the possible impact of blue light has received no research attention.

  18. A comparison of blue light and caffeine effects on cognitive function and alertness in humans.

    Directory of Open Access Journals (Sweden)

    C Martyn Beaven

    Full Text Available The alerting effects of both caffeine and short wavelength (blue light have been consistently reported. The ability of blue light to enhance alertness and cognitive function via non-image forming neuropathways have been suggested as a non-pharmacological countermeasure for drowsiness across a range of occupational settings. Here we compare and contrast the alerting and psychomotor effects of 240 mg of caffeine and a 1-h dose of ~40 lx blue light in a non-athletic population. Twenty-one healthy subjects performed a computer-based psychomotor vigilance test before and after each of four randomly assigned trial conditions performed on different days: white light/placebo; white light/240 mg caffeine; blue light/placebo; blue light/240 mg caffeine. The Karolinska Sleepiness Scale was used to assess subjective measures of alertness. Both the caffeine only and blue light only conditions enhanced accuracy in a visual reaction test requiring a decision and an additive effect was observed with respect to the fastest reaction times. However, in a test of executive function, where a distraction was included, caffeine exerted a negative effect on accuracy. Furthermore, the blue light only condition consistently outperformed caffeine when both congruent and incongruent distractions were presented. The visual reactions in the absence of a decision or distraction were also enhanced in the blue light only condition and this effect was most prominent in the blue-eyed participants. Overall, blue light and caffeine demonstrated distinct effects on aspects of psychomotor function and have the potential to positively influence a range of settings where cognitive function and alertness are important. Specifically, despite the widespread use of caffeine in competitive sporting environments, the possible impact of blue light has received no research attention.

  19. Verbal collision avoidance messages during simulated driving: perceived urgency, alerting effectiveness and annoyance.

    Science.gov (United States)

    Baldwin, Carryl L

    2011-04-01

    Matching the perceived urgency of an alert with the relative hazard level of the situation is critical for effective alarm response. Two experiments describe the impact of acoustic and semantic parameters on ratings of perceived urgency, annoyance and alerting effectiveness and on alarm response speed. Within a simulated driving context, participants rated and responded to collision avoidance system (CAS) messages spoken by a female or male voice (experiments 1 and 2, respectively). Results indicated greater perceived urgency and faster alarm response times as intensity increased from -2 dB signal to noise (S/N) ratio to +10 dB S/N, although annoyance ratings increased as well. CAS semantic content interacted with alarm intensity, indicating that at lower intensity levels participants paid more attention to the semantic content. Results indicate that both acoustic and semantic parameters independently and interactively impact CAS alert perceptions in divided attention conditions and this work can inform auditory alarm design for effective hazard matching. Matching the perceived urgency of an alert with the relative hazard level of the situation is critical for effective alarm response. Here, both acoustic and semantic parameters independently and interactively impacted CAS alert perceptions in divided attention conditions. This work can inform auditory alarm design for effective hazard matching. STATEMENT OF RELEVANCE: Results indicate that both acoustic parameters and semantic content can be used to design collision warnings with a range of urgency levels. Further, these results indicate that verbal warnings tailored to a specific hazard situation may improve hazard-matching capabilities without substantial trade-offs in perceived annoyance.

  20. Does one hour of bright or short-wavelength filtered tablet screenlight have a meaningful effect on adolescents' pre-bedtime alertness, sleep, and daytime functioning?

    Science.gov (United States)

    Heath, Melanie; Sutherland, Cate; Bartel, Kate; Gradisar, Michael; Williamson, Paul; Lovato, Nicole; Micic, Gorica

    2014-05-01

    Electronic media use is prevalent among adolescent populations, as is the frequency of sleeplessness. One mechanism proposed for technology affecting adolescents' sleep is the alerting effects from bright screens. Two explanations are provided. First, screens emit significant amounts of short-wavelength light (i.e. blue), which produces acute alertness and alters sleep timing. Second, later chronotypes are hypothesised to be hypersensitive to evening light. This study analysed the pre-sleep alertness (GO/NOGO task speed, accuracy; subjective sleepiness), sleep (sleep diary, polysomnography), and morning functioning of 16 healthy adolescents (M = 17.4 ± 1.9 yrs, 56% f) who used a bright tablet screen (80 lux), dim screen (1 lux) and a filtered short-wavelength screen (f.lux; 50 lux) for 1 hr before their usual bedtime in a within-subjects protocol. Chronotype was analysed as a continuous between-subjects factor; however, no significant interactions occurred. Significant effects occurred between bright and dim screens for GO/NOGO speed and accuracy. However, the magnitude of these differences was small (e.g. GO/NOGO speed = 23 ms, accuracy = 13%), suggesting minimal clinical significance. No significant effects were found for sleep onset latency, slow-rolling eye movements, or the number of SWS and REM minutes in the first two sleep cycles. Future independent studies are needed to test short (1 hr) vs longer (>2 hrs) screen usage to provide evidence for safe-to-harmful levels of screenlight exposure before adolescents' usual bedtime.

  1. Universal Design in the Technology Education Curriculum: Experiences from Norway

    OpenAIRE

    Sandnes, Frode Eika; Eika, Evelyn

    2017-01-01

    In recent decades the engineering and technology education curriculum has changed from being purely technical oriented towards being more socially aware. In addition, to adequately master technologies and subsequent technical problem solving, engineers need to be alert to potential social impacts of their work and reflect upon their decisions accordingly . Most engineering studies have included elements...

  2. How Do Science and Technology Affect International Affairs?

    Science.gov (United States)

    Weiss, Charles

    2015-01-01

    Science and technology influence international affairs by many different mechanisms. Both create new issues, risks and uncertainties. Advances in science alert the international community to new issues and risks. New technological capabilities transform war, diplomacy, commerce, intelligence, and investment. This paper identifies six basic…

  3. Exploring the heavy air pollution in Beijing in the fourth quarter of 2015: assessment of environmental benefits for red alerts

    Science.gov (United States)

    Nie, Teng; Nie, Lei; Zhou, Zhen; Wang, Zhanshan; Xue, Yifeng; Gao, Jiajia; Wu, Xiaoqing; Fan, Shoubin; Cheng, Linglong

    2018-06-01

    In recent years, Beijing has experienced severe air pollution which has caused widespread public concern. Compared to the same period in 2014, the first three quarters of 2015 exhibited significantly improved air quality. However, the air quality sharply declined in the fourth quarter of 2015, especially in November and December. During that time, Beijing issued the first red alert for severe air pollution in history. In total, 2 red alerts, 3 orange alerts, 3 yellow alerts, and 3 blue alerts were issued based on the adoption of relatively temporary emergency control measures to mitigate air pollution. This study explored the reasons for these variations in air quality and assessed the effectiveness of emergency alerts in addressing severe air pollution. A synthetic analysis of emission variations and meteorological conditions was performed to better understand these extreme air pollution episodes in the fourth quarter of 2015. The results showed that compared to those in the same period in 2014, the daily average emissions of air pollutants decreased in the fourth quarter of 2015. However, the emission levels of primary pollutants were still relatively high, which was the main intrinsic cause of haze episodes, and unfavorable meteorological conditions represented important external factors. Emergency control measures for heavy air pollution were implemented during this red alert period, decreasing the emissions of primary air pollutants by approximately 36% and the PM2.5 concentration by 11%‒21%.

  4. A systematic review of the effectiveness of interruptive medication prescribing alerts in hospital CPOE systems to change prescriber behavior and improve patient safety.

    Science.gov (United States)

    Page, N; Baysari, M T; Westbrook, J I

    2017-09-01

    To assess the evidence of the effectiveness of different categories of interruptive medication prescribing alerts to change prescriber behavior and/or improve patient outcomes in hospital computerized provider order entry (CPOE) systems. PubMed, Embase, CINAHL and the Cochrane Library were searched for relevant articles published between January 2000 and February 2016. Studies were included if they compared the outcomes of automatic, interruptive medication prescribing alert/s to a control/comparison group to determine alert effectiveness. Twenty-three studies describing 32 alerts classified into 11 alert categories were identified. The most common alert categories studied were drug-condition interaction (n=6), drug-drug interaction alerts (n=6) and corollary order alerts (n=6). All 23 papers investigated the effect of the intervention alert on at least one outcome measure of prescriber behavior. Just over half of the studies (53%, n=17) reported a statistically significant beneficial effect from the intervention alert; 34% (n=11) reported no statistically significant effect, and 6% (n=2) reported a significant detrimental effect. Two studies also evaluated the effect of alerts on patient outcome measures; neither finding that patient outcomes significantly improved following alert implementation (6%, n=2). The greatest volume of evidence relates to three alert categories: drug-condition, drug-drug and corollary order alerts. Of these, drug-condition alerts had the greatest number of studies reporting positive effects (five out of six studies). Only two of six studies of drug-drug interaction and one of six of corollary alerts reported positive benefits. The current evidence-base does not show a clear indication that particular categories of alerts are more effective than others. While the majority of alert categories were shown to improve outcomes in some studies, there were also many cases where outcomes did not improve. This lack of evidence hinders decisions

  5. Comparison of 'time to detection' values between BacT/ALERT VIRTUO and BacT/ALERT 3D instruments for clinical blood culture samples.

    Science.gov (United States)

    Congestrì, Francesco; Pedna, Maria Federica; Fantini, Michela; Samuelli, Michela; Schiavone, Pasqua; Torri, Arianna; Bertini, Stefania; Sambri, Vittorio

    2017-09-01

    The early detection of bacteraemia and fungemia is of paramount importance to guide antimicrobial therapy in septic patients. In this study the 'time to detection' (TTD) value for the new blood culture system BacT/ALERT VIRTUO (VIRTUO) was evaluated in 1462 positive clinical bottles and compared with the TTD for 1601 positive clinical bottles incubated in the BacT/ALERT 3D system (BTA-3D). The most representative microorganisms isolated from bottles incubated in both blood culture systems were divided into eight categories (in order of frequency): coagulase-negative staphylococci (CoNS), Escherichia coli, Enterobacteriaceae (other than E. coli), Staphylococcus aureus, Enterococcus spp, viridans group streptococci, Pseudomonas aeruginosa, and Candida spp. The comparison of TTD values for the two blood culture systems strongly indicated that growth of the first five groups listed above was detected earlier with VIRTUO than with BTA-3D (p culture system can reduce the TTD for more than 75% of isolated microorganisms. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. Alert: the dark side of chats--internet without boundaries.

    Science.gov (United States)

    Aderet, Avshalom

    2009-01-01

    mind was filled with suicidal thoughts he stumbled upon a group on the web that embraced the culture of death and suicide discussions. In his darkest moments, when he was on the verge of an abyss, he was probably pushed by these discussions into his death, and he was only 19-years-old. When Eshnav was created we saw the dangers of an Internet with no boundaries, a place where this remarkable technology was grossly misused. This is from the association's statement: "In a world without fences and boundaries clearer rules of conduct are needed." We emphasized that "the web is like a new world that has yet to determine its own boundaries. As such, it poses new challenges, both moral and ideological, which cannot be met based on past experience as this phenomenon is still too new and uncharted. We must do the utmost to be vigil about making the Internet as safe as possible even when this new frontier is constantly shifting and evolving." Let us bow our heads in sadness in memory of Eran whose strength did not withstand the great distress he was in, and who let himself be dragged by the death culture and darkness on the web into an untimely grave. We shall find strength in our determination to create a responsible web community in which freedom of speech will not be abused to hurt the individual rights of each and every human being to life, respect, reputation and privacy.

  7. In Silico Prediction of Chemical Toxicity for Drug Design Using Machine Learning Methods and Structural Alerts

    Science.gov (United States)

    Yang, Hongbin; Sun, Lixia; Li, Weihua; Liu, Guixia; Tang, Yun

    2018-02-01

    For a drug, safety is always the most important issue, including a variety of toxicities and adverse drug effects, which should be evaluated in preclinical and clinical trial phases. This review article at first simply introduced the computational methods used in prediction of chemical toxicity for drug design, including machine learning methods and structural alerts. Machine learning methods have been widely applied in qualitative classification and quantitative regression studies, while structural alerts can be regarded as a complementary tool for lead optimization. The emphasis of this article was put on the recent progress of predictive models built for various toxicities. Available databases and web servers were also provided. Though the methods and models are very helpful for drug design, there are still some challenges and limitations to be improved for drug safety assessment in the future.

  8. In Silico Prediction of Chemical Toxicity for Drug Design Using Machine Learning Methods and Structural Alerts

    Directory of Open Access Journals (Sweden)

    Hongbin Yang

    2018-02-01

    Full Text Available During drug development, safety is always the most important issue, including a variety of toxicities and adverse drug effects, which should be evaluated in preclinical and clinical trial phases. This review article at first simply introduced the computational methods used in prediction of chemical toxicity for drug design, including machine learning methods and structural alerts. Machine learning methods have been widely applied in qualitative classification and quantitative regression studies, while structural alerts can be regarded as a complementary tool for lead optimization. The emphasis of this article was put on the recent progress of predictive models built for various toxicities. Available databases and web servers were also provided. Though the methods and models are very helpful for drug design, there are still some challenges and limitations to be improved for drug safety assessment in the future.

  9. In Silico Prediction of Chemical Toxicity for Drug Design Using Machine Learning Methods and Structural Alerts.

    Science.gov (United States)

    Yang, Hongbin; Sun, Lixia; Li, Weihua; Liu, Guixia; Tang, Yun

    2018-01-01

    During drug development, safety is always the most important issue, including a variety of toxicities and adverse drug effects, which should be evaluated in preclinical and clinical trial phases. This review article at first simply introduced the computational methods used in prediction of chemical toxicity for drug design, including machine learning methods and structural alerts. Machine learning methods have been widely applied in qualitative classification and quantitative regression studies, while structural alerts can be regarded as a complementary tool for lead optimization. The emphasis of this article was put on the recent progress of predictive models built for various toxicities. Available databases and web servers were also provided. Though the methods and models are very helpful for drug design, there are still some challenges and limitations to be improved for drug safety assessment in the future.

  10. The combination of L-theanine and caffeine improves cognitive performance and increases subjective alertness.

    Science.gov (United States)

    Giesbrecht, T; Rycroft, J A; Rowson, M J; De Bruin, E A

    2010-12-01

    The non-proteinic amino acid L-theanine and caffeine, a methylxanthine derivative, are naturally occurring ingredients in tea. The present study investigated the effect of a combination of 97 mg L-theanine and 40 mg caffeine as compared to placebo treatment on cognitive performance, alertness, blood pressure, and heart rate in a sample of young adults (n = 44). Cognitive performance, self-reported mood, blood pressure, and heart rate were measured before L-theanine and caffeine administration (i.e. at baseline) and 20 min and 70 min thereafter. The combination of moderate levels of L-theanine and caffeine significantly improved accuracy during task switching and self-reported alertness (both P effects on other cognitive tasks, such as visual search, choice reaction times, or mental rotation. The present results suggest that 97 mg of L-theanine in combination with 40 mg of caffeine helps to focus attention during a demanding cognitive task.

  11. Effect of air quality alerts on human health: a regression discontinuity analysis in Toronto, Canada.

    Science.gov (United States)

    Chen, Hong; Li, Qiongsi; Kaufman, Jay S; Wang, Jun; Copes, Ray; Su, Yushan; Benmarhnia, Tarik

    2018-01-01

    Ambient air pollution is a major health risk globally. To reduce adverse health effects on days when air pollution is high, government agencies worldwide have implemented air quality alert programmes. Despite their widespread use, little is known about whether these programmes produce any observable public-health benefits. We assessed the effectiveness of such programmes using a quasi-experimental approach. We assembled a population-based cohort comprising all individuals who resided in the city of Toronto (Ontario, Canada) from 2003 to 2012 (about 2·6 million people). We ascertained seven health outcomes known to be affected by short-term elevation of air pollution, using provincial health administrative databases. These health outcomes were cardiovascular-related mortality, respiratory-related mortality, and hospital admissions or emergency-department visits for acute myocardial infarction, heart failure, stroke, asthma, and chronic obstructive pulmonary disease (COPD). We applied a regression discontinuity design to assess the effectiveness of an intervention (ie, the air quality alert programme). To quantify the effect of the air quality alert programme, we estimated for each outcome both the absolute rate difference and the rate ratio attributable to programme eligibility (by intention-to-treat analysis) and the alerts themselves (by two-stage regression approach), respectively. Between Jan 1, 2003, and Dec 31, 2012, on average between three and 27 daily cardiovascular or respiratory events were reported in Toronto (depending on the outcome). Alert announcements reduced asthma-related emergency-department visits by 4·73 cases per 1 000 000 people per day (95% CI 0·55-9·38), or in relative terms by 25% (95% CI 1-47). Programme eligibility also led to 2·05 (95% CI 0·07-4·00) fewer daily emergency-department visits for asthma. We did not detect a significant reduction in any other health outcome as a result of alert announcements or programme

  12. Intrusion-Aware Alert Validation Algorithm for Cooperative Distributed Intrusion Detection Schemes of Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Young-Jae Song

    2009-07-01

    Full Text Available Existing anomaly and intrusion detection schemes of wireless sensor networks have mainly focused on the detection of intrusions. Once the intrusion is detected, an alerts or claims will be generated. However, any unidentified malicious nodes in the network could send faulty anomaly and intrusion claims about the legitimate nodes to the other nodes. Verifying the validity of such claims is a critical and challenging issue that is not considered in the existing cooperative-based distributed anomaly and intrusion detection schemes of wireless sensor networks. In this paper, we propose a validation algorithm that addresses this problem. This algorithm utilizes the concept of intrusion-aware reliability that helps to provide adequate reliability at a modest communication cost. In this paper, we also provide a security resiliency analysis of the proposed intrusion-aware alert validation algorithm.

  13. Bioremediation of petroleum contaminated soil at CFS Alert - Laboratory scale respirometry experiment

    International Nuclear Information System (INIS)

    Haidar, S.; Bennett, J.; Jarrett, P.; Biggar, K.

    1998-01-01

    The feasibility of 'biopiling' was tested at Canadian Forces Station 'Alert', located in the high Arctic where the feasibility of bioremediation is yet to be proven. Laboratory respirometer experiments were conducted at 11 degrees C that examined the behaviour of indigenous microorganisms. Experiments were also carried out at one contaminated site. Various soil properties were analyzed, as well as total petroleum hydrocarbons. Results showed that the respirometer system functioned properly in monitoring the behaviour of microorganisms, that indigenous microorganisms were active at 11 degrees C, and that they functioned at a constant rate of oxygen consumption. These results suggest that biopiling may be feasible under the conditions existing at CFS 'Alert'. 12 refs., 5 tabs., 8 figs

  14. Distributed Pedestrian Detection Alerts Based on Data Fusion with Accurate Localization

    Directory of Open Access Journals (Sweden)

    Arturo de la Escalera

    2013-09-01

    Full Text Available Among Advanced Driver Assistance Systems (ADAS pedestrian detection is a common issue due to the vulnerability of pedestrians in the event of accidents. In the present work, a novel approach for pedestrian detection based on data fusion is presented. Data fusion helps to overcome the limitations inherent to each detection system (computer vision and laser scanner and provides accurate and trustable tracking of any pedestrian movement. The application is complemented by an efficient communication protocol, able to alert vehicles in the surroundings by a fast and reliable communication. The combination of a powerful location, based on a GPS with inertial measurement, and accurate obstacle localization based on data fusion has allowed locating the detected pedestrians with high accuracy. Tests proved the viability of the detection system and the efficiency of the communication, even at long distances. By the use of the alert communication, dangerous situations such as occlusions or misdetections can be avoided.

  15. Distributed pedestrian detection alerts based on data fusion with accurate localization.

    Science.gov (United States)

    García, Fernando; Jiménez, Felipe; Anaya, José Javier; Armingol, José María; Naranjo, José Eugenio; de la Escalera, Arturo

    2013-09-04

    Among Advanced Driver Assistance Systems (ADAS) pedestrian detection is a common issue due to the vulnerability of pedestrians in the event of accidents. In the present work, a novel approach for pedestrian detection based on data fusion is presented. Data fusion helps to overcome the limitations inherent to each detection system (computer vision and laser scanner) and provides accurate and trustable tracking of any pedestrian movement. The application is complemented by an efficient communication protocol, able to alert vehicles in the surroundings by a fast and reliable communication. The combination of a powerful location, based on a GPS with inertial measurement, and accurate obstacle localization based on data fusion has allowed locating the detected pedestrians with high accuracy. Tests proved the viability of the detection system and the efficiency of the communication, even at long distances. By the use of the alert communication, dangerous situations such as occlusions or misdetections can be avoided.

  16. Effects of an alert system on implantable cardioverter defibrillator-related anxiety

    DEFF Research Database (Denmark)

    Duru, Firat; Dorian, Paul; Favale, Stefano

    2010-01-01

    failing to receive needed therapy for the same reason. New devices include programmable vibrating patient notifiers (PN), which, by warning patients of a possible device dysfunction, might lower device-related anxiety. PAtient NOtifier feature for Reduction of Anxiety: a Multicentre ICD study (PANORAMIC......) is a multicentre, randomized, clinical trial designed to examine the effects of the awareness of an active vibrating alert system on device-related anxiety....

  17. Discussion of “Attitude of Physicians Towards Automatic Alerting in Computerized Physician Order Entry Systems”

    DEFF Research Database (Denmark)

    Bates, D. W.; Baysari, M. T.; Dugas, M.

    2013-01-01

    With these comments on the paper “Attitude of Physicians Towards Automatic Alerting in Computerized Physician Order Entry Systems”, written by Martin Jung and coauthors, with Dr. Elske Ammenwerth as senior author, the journal wants to stimulate a broad discussion on computerized physician order...... entry systems. An international group of experts have been invited by the editor of Methods to comment on this paper. Each of the invited commentaries forms one section of this paper....

  18. Optical and X-Ray Early Follow-Up of ANTARES Neutrino Alerts

    Science.gov (United States)

    Adrian-Martinez, S.; Ageron, M.; Albert, A.; Samarai, I. Al; Andre, M.; Anton, G.; Ardid, M.; Aubert, J.-J.; Baret, B.; Barrios-Marti, J.; hide

    2016-01-01

    High-energy neutrinos could be produced in the interaction of charged cosmic rays with matter or radiation surrounding astrophysical sources. Even with the recent detection of extraterrestrial high-energy neutrinos by the IceCube experiment, no astrophysical neutrinosource has yet been discovered. Transient sources, such as gamma-ray bursts, core-collapse supernovae, or active galactic nuclei are promising candidates. Multi-messenger programs offer a unique opportunity to detect these transient sources. By combining the information provided by the ANTARES neutrino telescope with information coming from other observatories, the probability of detecting a source is enhanced, allowing the possibility of identifyinga neutrino progenitor from a single detected event. A method based on optical and X-ray follow-ups of high-energy neutrino alerts has been developed within the ANTARES collaboration. This method does not require any assumptions on the relation between neutrino and photon spectra other than time-correlation. This program, denoted as TAToO, triggers a network of robotic optical telescopes (TAROTand ROTSE) and the Swift-XRT with a delay of only a few seconds after a neutrino detection, and is therefore well-suited to search for fast transient sources. To identify an optical or Xraycounterpart to a neutrino signal, the images provided by the follow-up observations areanalysed with dedicated pipelines. A total of 42 alerts with optical and 7 alerts with X-ray images taken with a maximum delay of 24 hours after the neutrino trigger have been analyzed. No optical or X-ray counterparts associated to the neutrino triggers have been found, and upper limits on transient source magnitudes have been derived. The probability to reject the gamma-ray burst origin hypothesis has been computed for each alert.

  19. Dexterous robotic manipulation of alert adult Drosophila for high-content experimentation.

    Science.gov (United States)

    Savall, Joan; Ho, Eric Tatt Wei; Huang, Cheng; Maxey, Jessica R; Schnitzer, Mark J

    2015-07-01

    We present a robot that enables high-content studies of alert adult Drosophila by combining operations including gentle picking; translations and rotations; characterizations of fly phenotypes and behaviors; microdissection; or release. To illustrate, we assessed fly morphology, tracked odor-evoked locomotion, sorted flies by sex, and dissected the cuticle to image neural activity. The robot's tireless capacity for precise manipulations enables a scalable platform for screening flies' complex attributes and behavioral patterns.

  20. Simultaneous transcranial magnetic stimulation and single neuron recording in alert non-human primates

    OpenAIRE

    Mueller, Jerel K.; Grigsby, Erinn M.; Prevosto, Vincent; Petraglia, Frank W.; Rao, Hrishikesh; Deng, Zhi-De; Peterchev, Angel V.; Sommer, Marc A.; Egner, Tobias; Platt, Michael L.; Grill, Warren M.

    2014-01-01

    Transcranial magnetic stimulation (TMS) is a widely used, noninvasive method for stimulating nervous tissue, yet its mechanisms of effect are poorly understood. Here we report novel methods for studying the influence of TMS on single neurons in the brain of alert non-human primates. We designed a TMS coil that focuses its effect near the tip of a recording electrode and recording electronics that enable direct acquisition of neuronal signals at the site of peak stimulus strength minimally per...

  1. Optical Flow and Driver’s Kinematics Analysis for State of Alert Sensing

    Directory of Open Access Journals (Sweden)

    Miguel Torres-Torriti

    2013-03-01

    Full Text Available Road accident statistics from different countries show that a significant number of accidents occur due to driver’s fatigue and lack of awareness to traffic conditions. In particular, about 60% of the accidents in which long haul truck and bus drivers are involved are attributed to drowsiness and fatigue. It is thus fundamental to improve non-invasive systems for sensing a driver’s state of alert. One of the main challenges to correctly resolve the state of alert is measuring the percentage of eyelid closure over time (PERCLOS, despite the driver’s head and body movements. In this paper, we propose a technique that involves optical flow and driver’s kinematics analysis to improve the robustness of the driver’s alert state measurement under pose changes using a single camera with near-infrared illumination. The proposed approach infers and keeps track of the driver’s pose in 3D space in order to ensure that eyes can be located correctly, even after periods of partial occlusion, for example, when the driver stares away from the camera. Our experiments show the effectiveness of the approach with a correct eyes detection rate of 99.41%, on average. The results obtained with the proposed approach in an experiment involving fifteen persons under different levels of sleep deprivation also confirm the discriminability of the fatigue levels. In addition to the measurement of fatigue and drowsiness, the pose tracking capability of the proposed approach has potential applications in distraction assessment and alerting of machine operators.

  2. Quality of prescription of high-alert medication and patient safety in pediatric emergency

    Directory of Open Access Journals (Sweden)

    V. Vieira de Melo

    2014-01-01

    Full Text Available Objective: Verify the importance of compliance by prescribed doses of high-alert medications in unit of pediatric emergency in patient safety. Method: This was a cross-sectional descriptive study conducted in a unit of pediatric emergency, for March to April of 2012. This study included all prescriptions that contained at least one high-alert medication, excluding all of others. The data were analyzed using Microsoft Office Excel® version 2007, and the study was approved by the Research Ethics Committee of the Hospital. Results: This study included prescriptions for 100 patients with a mean age of 5.2 ± 4.2 years. Were identified 983 (40.1% high-alert medications (21 different, with predominance of injectable solutions (834, 84,8%, and of these 727 (73.95% were electrolytes. The analysis of the dose was possible for 641 electrolytes and 104 non-electrolytes, being the dose inadequacies observed for some medications. Was observed concentration absent to 189 (18.9% prescribed medications, these with liquid pharmaceutical form or aerosol. Was observed also the absence of maximum dose for 8 (36.3% prescribed drugs “if necessary”. Conclusión: The inadequacies of doses of high-alert medications identified in this study may compromise patient safety, demonstrating the importance of knowledge of multidisciplinary health care team by this subject, in this context, it is noteworthy that the acting of a clinical pharmacist together with the health multidisciplined team can contributes with the review of drug prescriptions, reducing potential errors and collaborating with patient safety.

  3. Optical and X-ray early follow-up of ANTARES neutrino alerts

    International Nuclear Information System (INIS)

    Adrián-Martínez, S.; Ardid, M.; Ageron, M.; Al Samarai, I.; Aubert, J.-J.; Albert, A.; André, M.; Anton, G.; Baret, B.; Barrios-Martí, J.

    2016-01-01

    High-energy neutrinos could be produced in the interaction of charged cosmic rays with matter or radiation surrounding astrophysical sources. Even with the recent detection of extraterrestrial high-energy neutrinos by the IceCube experiment, no astrophysical neutrino source has yet been discovered. Transient sources, such as gamma-ray bursts, core-collapse supernovae, or active galactic nuclei are promising candidates. Multi-messenger programs offer a unique opportunity to detect these transient sources. By combining the information provided by the ANTARES neutrino telescope with information coming from other observatories, the probability of detecting a source is enhanced, allowing the possibility of identifying a neutrino progenitor from a single detected event. A method based on optical and X-ray follow-ups of high-energy neutrino alerts has been developed within the ANTARES collaboration. This method does not require any assumptions on the relation between neutrino and photon spectra other than time-correlation. This program, denoted as TAToO, triggers a network of robotic optical telescopes (TAROT and ROTSE) and the Swift-XRT with a delay of only a few seconds after a neutrino detection, and is therefore well-suited to search for fast transient sources. To identify an optical or X-ray counterpart to a neutrino signal, the images provided by the follow-up observations are analysed with dedicated pipelines. A total of 42 alerts with optical and 7 alerts with X-ray images taken with a maximum delay of 24 hours after the neutrino trigger have been analysed. No optical or X-ray counterparts associated to the neutrino triggers have been found, and upper limits on transient source magnitudes have been derived. The probability to reject the gamma-ray burst origin hypothesis has been computed for each alert

  4. Optical and X-ray early follow-up of ANTARES neutrino alerts

    Science.gov (United States)

    Adrián-Martínez, S.; Ageron, M.; Albert, A.; Samarai, I. Al; André, M.; Anton, G.; Ardid, M.; Aubert, J.-J.; Baret, B.; Barrios-Martí, J.; Basa, S.; Bertin, V.; Biagi, S.; Bogazzi, C.; Bormuth, R.; Bou-Cabo, M.; Bouwhuis, M. C.; Bruijn, R.; Brunner, J.; Busto, J.; Capone, A.; Caramete, L.; Carr, J.; Chiarusi, T.; Circella, M.; Coniglione, R.; Costantini, H.; Coyle, P.; Creusot, A.; Dekeyser, I.; Deschamps, A.; De Bonis, G.; Distefano, C.; Donzaud, C.; Dornic, D.; Drouhin, D.; Dumas, A.; Eberl, T.; Elsässer, D.; Enzenhöfer, A.; Fehn, K.; Felis, I.; Fermani, P.; Folger, F.; Fusco, L. A.; Galatà, S.; Gay, P.; Geißelsöder, S.; Geyer, K.; Giordano, V.; Gleixner, A.; Gracia-Ruiz, R.; Graf, K.; van Haren, H.; Heijboer, A. J.; Hello, Y.; Hernández-Rey, J. J.; Herrero, A.; Hößl, J.; Hofestädt, J.; Hugon, C.; James, C. W.; de Jong, M.; Kadler, M.; Kalekin, O.; Katz, U.; Kießling, D.; Kooijman, P.; Kouchner, A.; Kreykenbohm, I.; Kulikovskiy, V.; Lahmann, R.; Lambard, G.; Lattuada, D.; Lefèvre, D.; Leonora, E.; Loucatos, S.; Mangano, S.; Marcelin, M.; Margiotta, A.; Martínez-Mora, J. A.; Martini, S.; Mathieu, A.; Michael, T.; Migliozzi, P.; Moussa, A.; Mueller, C.; Neff, M.; Nezri, E.; Păvălaš, G. E.; Pellegrino, C.; Perrina, C.; Piattelli, P.; Popa, V.; Pradier, T.; Racca, C.; Riccobene, G.; Richter, R.; Roensch, K.; Rostovtsev, A.; Saldaña, M.; Samtleben, D. F. E.; Sanguineti, M.; Sapienza, P.; Schmid, J.; Schnabel, J.; Schulte, S.; Schüssler, F.; Seitz, T.; Sieger, C.; Spurio, M.; Steijger, J. J. M.; Stolarczyk, Th.; Sánchez-Losa, A.; Taiuti, M.; Tamburini, C.; Trovato, A.; Tselengidou, M.; Tönnis, C.; Turpin, D.; Vallage, B.; Vallée, C.; Van Elewyck, V.; Vecchi, M.; Visser, E.; Vivolo, D.; Wagner, S.; Wilms, J.; Zornoza, J. D.; Zúñiga, J.; Klotz, A.; Boer, M.; Le Van Suu, A.; Akerlof, C.; Zheng, W.; Evans, P.; Gehrels, N.; Kennea, J.; Osborne, J. P.; Coward, D. M.

    2016-02-01

    High-energy neutrinos could be produced in the interaction of charged cosmic rays with matter or radiation surrounding astrophysical sources. Even with the recent detection of extraterrestrial high-energy neutrinos by the IceCube experiment, no astrophysical neutrino source has yet been discovered. Transient sources, such as gamma-ray bursts, core-collapse supernovae, or active galactic nuclei are promising candidates. Multi-messenger programs offer a unique opportunity to detect these transient sources. By combining the information provided by the ANTARES neutrino telescope with information coming from other observatories, the probability of detecting a source is enhanced, allowing the possibility of identifying a neutrino progenitor from a single detected event. A method based on optical and X-ray follow-ups of high-energy neutrino alerts has been developed within the ANTARES collaboration. This method does not require any assumptions on the relation between neutrino and photon spectra other than time-correlation. This program, denoted as TAToO, triggers a network of robotic optical telescopes (TAROT and ROTSE) and the Swift-XRT with a delay of only a few seconds after a neutrino detection, and is therefore well-suited to search for fast transient sources. To identify an optical or X-ray counterpart to a neutrino signal, the images provided by the follow-up observations are analysed with dedicated pipelines. A total of 42 alerts with optical and 7 alerts with X-ray images taken with a maximum delay of 24 hours after the neutrino trigger have been analysed. No optical or X-ray counterparts associated to the neutrino triggers have been found, and upper limits on transient source magnitudes have been derived. The probability to reject the gamma-ray burst origin hypothesis has been computed for each alert.

  5. Warfarin monitoring in nursing homes assessed by case histories. Do recommendations and electronic alerts affect judgements?

    Science.gov (United States)

    Teruel, Reyes Serrano; Thue, Geir; Fylkesnes, Svein Ivar; Sandberg, Sverre; Kristoffersen, Ann Helen

    2017-09-01

    Older adults treated with warfarin are prone to complications, and high-quality monitoring is essential. The aim of this case history based study was to assess the quality of warfarin monitoring in a routine situation, and in a situation with an antibiotic-warfarin interaction, before and after receiving an electronic alert. In April 2014, a national web-based survey with two case histories was distributed among Norwegian nursing home physicians and general practitioners working part-time in nursing homes. Case A represented a patient on stable warfarin treatment, but with a substantial INR increase within the therapeutic interval. Case B represented a more challenging patient with trimethoprim sulfamethoxazole (TMS) treatment due to pyelonephritis. In both cases, the physicians were asked to state the next warfarin dose and the INR recall interval. In case B, the physicians could change their suggestions after receiving an electronic alert on the TMS-warfarin interaction. Three hundred and ninety eight physicians in 292 nursing homes responded. Suggested INR recall intervals and warfarin doses varied substantially in both cases. In case A, 61% gave acceptable answers according to published recommendations, while only 9% did so for case B. Regarding the TMS-warfarin interaction in case history B, the electronic alert increased the percentage of respondents correctly suggesting a dose reduction from 29% to 53%. Having an INR instrument in the nursing home was associated with shortened INR recall times. Practical advice on handling of warfarin treatment and drug interactions is needed. Electronic alerts as presented in electronic medical records seem insufficient to change practice. Availability of INR instruments may be important regarding recall time.

  6. The effects of spectral tuning of evening ambient light on melatonin suppression, alertness and sleep.

    Science.gov (United States)

    Rahman, Shadab A; St Hilaire, Melissa A; Lockley, Steven W

    2017-08-01

    We compared the effects of bedroom-intensity light from a standard fluorescent and a blue- (i.e., short-wavelength) depleted LED source on melatonin suppression, alertness, and sleep. Sixteen healthy participants (8 females) completed a 4-day inpatient study. Participants were exposed to blue-depleted circadian-sensitive (C-LED) light and a standard fluorescent light (FL, 4100K) of equal illuminance (50lx) for 8h prior to a fixed bedtime on two separate days in a within-subject, randomized, cross-over design. Each light exposure day was preceded by a dim light (LED conditions compared to FL 30min prior to bedtime. EEG-based correlates of alertness corroborated the reduced alertness under C-LED conditions as shown by significantly increased EEG spectral power in the delta-theta (0.5-8.0Hz) bands under C-LED as compared to FL exposure. There was no significant difference in total sleep time (TST), sleep efficiency (SE%), and slow-wave activity (SWA) between the two conditions. Unlike melatonin suppression and alertness, a significant order effect was observed on all three sleep variables, however. Individuals who received C-LED first and then FL had increased TST, SE% and SWA averaged across both nights compared to individuals who received FL first and then C-LED. These data show that the spectral characteristics of light can be fine-tuned to attenuate non-visual responses to light in humans. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Morning sleep inertia in alertness and performance: effect of cognitive domain and white light conditions.

    Directory of Open Access Journals (Sweden)

    Nayantara Santhi

    Full Text Available The transition from sleep to wakefulness entails a temporary period of reduced alertness and impaired performance known as sleep inertia. The extent to which its severity varies with task and cognitive processes remains unclear. We examined sleep inertia in alertness, attention, working memory and cognitive throughput with the Karolinska Sleepiness Scale (KSS, the Psychomotor Vigilance Task (PVT, n-back and add tasks, respectively. The tasks were administered 2 hours before bedtime and at regular intervals for four hours, starting immediately after awakening in the morning, in eleven participants, in a four-way cross-over laboratory design. We also investigated whether exposure to Blue-Enhanced or Bright Blue-Enhanced white light would reduce sleep inertia. Alertness and all cognitive processes were impaired immediately upon awakening (p<0.01. However, alertness and sustained attention were more affected than cognitive throughput and working memory. Moreover, speed was more affected than accuracy of responses. The light conditions had no differential effect on performance except in the 3-back task (p<0.01, where response times (RT at the end of four hours in the two Blue-Enhanced white light conditions were faster (200 ms than at wake time. We conclude that the effect of sleep inertia varies with cognitive domain and that it's spectral/intensity response to light is different from that of sleepiness. That is, just increasing blue-wavelength in light may not be sufficient to reduce sleep inertia. These findings have implications for critical professions like medicine, law-enforcement etc., in which, personnel routinely wake up from night-time sleep to respond to emergency situations.

  8. [Summarizing of medicinal alerts in Ivory Coast from 2001 till 2010].

    Science.gov (United States)

    N'Guessan-Irié, Amenan Geneviève; Yavo, Jean-Claude; Guillaume Amari, Antoine Serge; Yapi, Ange Désiré

    2012-01-01

    STUDY'S AIM: This study aims a more efficient follow-up of the safety of medicines with human usage on the Ivory Coast territory. The structure responsible for pharmacovigilance in Ivory Coast i.e. DPM listed the medicinal alerts from 2001 till 2010. It emerges 237 medicinal alerts among which 145 stops of marketing, 55 withdrawals of lots, 33 information notes and 4 levying of suspension of medicines. These alerts result mainly from pharmaceutical companies (49%) and the French Drug Agency or ANSM (ex-Afssaps) (43%). They mainly concern drugs of infectious target (22%) and pneumology (18%) and their motivations are so much industrial with mainly commercial reasons (27%) as of pharmacovigilance dominated by unfavorable profit/risk connections. These results constitute an important database for the survey of the medicines market in Ivory Coast and an additional motivation to accelerate the implementation of a real national center of pharmacovigilance. © 2012 Société Française de Pharmacologie et de Thérapeutique.

  9. Crew Factors in Flight Operations XV: Alertness Management in General Aviation Education Module

    Science.gov (United States)

    Rosekind, Mark R.; Co, Elizabeth L.; Neri, David F.; Oyung, Raymond L.; Mallis, Melissa M.; Cannon, Mary M. (Technical Monitor)

    2002-01-01

    Regional operations encompass a broad range of pilots and equipment. This module is intended to help all those involved in regional aviation, including pilots, schedulers, dispatchers, maintenance technicians, policy makers, and others, to understand the physiological factors underlying fatigue, how flight operations affect fatigue, and what can be done to counteract fatigue and maximize alertness and performance in their operations. The overall purpose of this module is to promote aviation safety, performance, and productivity. It is intended to meet three specific objectives: (1) to explain the current state of knowledge about the physiological mechanisms underlying fatigue; (2) to demonstrate how this knowledge can be applied to improving flight crew sleep, performance, and alertness; and (3) to offer strategies for alertness management. Aviation Safety Reporting System (ASRS) and National Transportation Safety Board (NISH) reports are used throughout this module to demonstrate that fatigue is a safety issue in the regional operations community. The appendices at the end of this module include the ASRS reports used for the examples contained in this publication, brief introductions to sleep disorders and relaxation techniques, summaries of relevant NASA publications, and a list of general readings on sleep, sleep disorders, and circadian rhythms.

  10. Investigation into the value of trained glycaemia alert dogs to clients with type I diabetes.

    Science.gov (United States)

    Rooney, Nicola J; Morant, Steve; Guest, Claire

    2013-01-01

    Previous studies have suggested that some pet dogs respond to their owners' hypoglycaemic state. Here, we show that trained glycaemia alert dogs placed with clients living with diabetes afford significant improvements to owner well-being. We investigated whether trained dogs reliably respond to their owners' hypoglycaemic state, and whether owners experience facilitated tightened glycaemic control, and wider psychosocial benefits. Since obtaining their dog, all seventeen clients studied reported positive effects including reduced paramedic call outs, decreased unconscious episodes and improved independence. Owner-recorded data showed that dogs alerted their owners, with significant, though variable, accuracy at times of low and high blood sugar. Eight out of the ten dogs (for which owners provided adequate records) responded consistently more often when their owner's blood sugars were reported to be outside, than within, target range. Comparison of nine clients' routine records showed significant overall change after obtaining their dogs, with seven clients recording a significantly higher proportion of routine tests within target range after obtaining a dog. HbA1C showed a small, non significant reduction after dog allocation. Based on owner-reported data we have shown, for the first time, that trained detection dogs perform above chance level. This study points to the potential value of alert dogs, for increasing glycaemic control, client independence and consequent quality of life and even reducing the costs of long-term health care.

  11. Investigation into the value of trained glycaemia alert dogs to clients with type I diabetes.

    Directory of Open Access Journals (Sweden)

    Nicola J Rooney

    Full Text Available Previous studies have suggested that some pet dogs respond to their owners' hypoglycaemic state. Here, we show that trained glycaemia alert dogs placed with clients living with diabetes afford significant improvements to owner well-being. We investigated whether trained dogs reliably respond to their owners' hypoglycaemic state, and whether owners experience facilitated tightened glycaemic control, and wider psychosocial benefits. Since obtaining their dog, all seventeen clients studied reported positive effects including reduced paramedic call outs, decreased unconscious episodes and improved independence. Owner-recorded data showed that dogs alerted their owners, with significant, though variable, accuracy at times of low and high blood sugar. Eight out of the ten dogs (for which owners provided adequate records responded consistently more often when their owner's blood sugars were reported to be outside, than within, target range. Comparison of nine clients' routine records showed significant overall change after obtaining their dogs, with seven clients recording a significantly higher proportion of routine tests within target range after obtaining a dog. HbA1C showed a small, non significant reduction after dog allocation. Based on owner-reported data we have shown, for the first time, that trained detection dogs perform above chance level. This study points to the potential value of alert dogs, for increasing glycaemic control, client independence and consequent quality of life and even reducing the costs of long-term health care.

  12. Alertness Management In Flight Operations: A NASA Education and Training Module

    Science.gov (United States)

    Rosekind, Mark R.; Lebacqz, Victor J.; Gander, Philippa H.; Co, Elizabeth L.; Weldon, Keri J.; Smith, Roy M.; Miller, Donna L.; Gregory, Kevin B.; Statler, Irving C. (Technical Monitor)

    1994-01-01

    Since 1980, the NASA Ames Fatigue Countermeasures Program has been conducting research on sleep, circadian rhythms, and fatigue in a variety of flight operations 1. An original goal of the program was to return the scientific and operational knowledge to the aviation industry. To meet this goal, the NASA Ames Fatigue Countermeasures Program has created an Education and Training Module entitled, "Strategies for Alertness Management in Flight Operations." The Module was designed to meet three objectives: 1) explain the current state of knowledge about the physiological mechanisms underlying fatigue, 2) demonstrate how this knowledge can be applied to improve flight crew sleep, performance, and alertness, and 3) offer countermeasure recommendations. The Module is composed of two components: 1) a 60-minute live presentation provided by a knowledgeable individual and 2) a NASA/FAA Technical Memorandum (TM) that contains the presentation materials and appendices with complementary information. The TM is provided to all individuals attending the live presentation. The Module content is divided into three parts: 1) basic information on sleep, sleepiness, circadian rhythms, fatigue, and how flight operations affect these physiological factors, 2) common misconceptions about sleep, sleepiness, and fatigue, and 3) alertness management strategies. The Module is intended for pilots, management personnel, schedulers, flight attendants, and the many other individuals involved in the aviation system.

  13. Morning Sleep Inertia in Alertness and Performance: Effect of Cognitive Domain and White Light Conditions

    Science.gov (United States)

    Santhi, Nayantara; Groeger, John A.; Archer, Simon N.; Gimenez, Marina; Schlangen, Luc J. M.; Dijk, Derk-Jan

    2013-01-01

    The transition from sleep to wakefulness entails a temporary period of reduced alertness and impaired performance known as sleep inertia. The extent to which its severity varies with task and cognitive processes remains unclear. We examined sleep inertia in alertness, attention, working memory and cognitive throughput with the Karolinska Sleepiness Scale (KSS), the Psychomotor Vigilance Task (PVT), n-back and add tasks, respectively. The tasks were administered 2 hours before bedtime and at regular intervals for four hours, starting immediately after awakening in the morning, in eleven participants, in a four-way cross-over laboratory design. We also investigated whether exposure to Blue-Enhanced or Bright Blue-Enhanced white light would reduce sleep inertia. Alertness and all cognitive processes were impaired immediately upon awakening (pinertia varies with cognitive domain and that it’s spectral/intensity response to light is different from that of sleepiness. That is, just increasing blue-wavelength in light may not be sufficient to reduce sleep inertia. These findings have implications for critical professions like medicine, law-enforcement etc., in which, personnel routinely wake up from night-time sleep to respond to emergency situations. PMID:24260280

  14. Crew Factors in Flight Operations XIV: Alertness Management in Regional Flight Operations Education Module

    Science.gov (United States)

    Rosekind, Mark R.; Co, Elizabeth L.; Neri, David F.; Oyung, Raymond L.; Mallis, Melissa M.

    2002-01-01

    Regional operations encompass a broad range of pilots and equipment. This module is intended to help all those involved in regional aviation, including pilots, schedulers, dispatchers, maintenance technicians, policy makers, and others, to understand the physiological factors underlying fatigue, how flight operations affect fatigue, and what can be done to counteract fatigue and maximize alertness and performance in their operations. The overall purpose of this module is to promote aviation safety, performance, and productivity. It is intended to meet three specific objectives: (1) to explain the current state of knowledge about the physiological mechanisms underlying fatigue; (2) to demonstrate how this knowledge can be applied to improving flight crew sleep, performance, and alertness; and (3) to offer strategies for alertness management. Aviation Safety Reporting System (ASRS) and National Transportation Safety Board (NISH) reports are used throughout this module to demonstrate that fatigue is a safety issue in the regional operations community. The appendices at the end of this module include the ASRS reports used for the examples contained in this publication, brief introductions to sleep disorders and relaxation techniques, summaries of relevant NASA publications, and a list of general readings on sleep, sleep disorders, and circadian rhythms.

  15. Effects of historical and predictive information on ability of transport pilot to predict an alert

    Science.gov (United States)

    Trujillo, Anna C.

    1994-01-01

    In the aviation community, the early detection of the development of a possible subsystem problem during a flight is potentially useful for increasing the safety of the flight. Commercial airlines are currently using twin-engine aircraft for extended transport operations over water, and the early detection of a possible problem might increase the flight crew's options for safely landing the aircraft. One method for decreasing the severity of a developing problem is to predict the behavior of the problem so that appropriate corrective actions can be taken. To investigate the pilots' ability to predict long-term events, a computer workstation experiment was conducted in which 18 airline pilots predicted the alert time (the time to an alert) using 3 different dial displays and 3 different parameter behavior complexity levels. The three dial displays were as follows: standard (resembling current aircraft round dial presentations); history (indicating the current value plus the value of the parameter 5 sec in the past); and predictive (indicating the current value plus the value of the parameter 5 sec into the future). The time profiles describing the behavior of the parameter consisted of constant rate-of-change profiles, decelerating profiles, and accelerating-then-decelerating profiles. Although the pilots indicated that they preferred the near term predictive dial, the objective data did not support its use. The objective data did show that the time profiles had the most significant effect on performance in estimating the time to an alert.

  16. Automatic recognition of alertness and drowsiness from EEG by an artificial neural network.

    Science.gov (United States)

    Vuckovic, Aleksandra; Radivojevic, Vlada; Chen, Andrew C N; Popovic, Dejan

    2002-06-01

    We present a novel method for classifying alert vs drowsy states from 1 s long sequences of full spectrum EEG recordings in an arbitrary subject. This novel method uses time series of interhemispheric and intrahemispheric cross spectral densities of full spectrum EEG as the input to an artificial neural network (ANN) with two discrete outputs: drowsy and alert. The experimental data were collected from 17 subjects. Two experts in EEG interpretation visually inspected the data and provided the necessary expertise for the training of an ANN. We selected the following three ANNs as potential candidates: (1) the linear network with Widrow-Hoff (WH) algorithm; (2) the non-linear ANN with the Levenberg-Marquardt (LM) rule; and (3) the Learning Vector Quantization (LVQ) neural network. We showed that the LVQ neural network gives the best classification compared with the linear network that uses WH algorithm (the worst), and the non-linear network trained with the LM rule. Classification properties of LVQ were validated using the data recorded in 12 healthy volunteer subjects, yet whose EEG recordings have not been used for the training of the ANN. The statistics were used as a measure of potential applicability of the LVQ: the t-distribution showed that matching between the human assessment and the network output was 94.37+/-1.95%. This result suggests that the automatic recognition algorithm is applicable for distinguishing between alert and drowsy state in recordings that have not been used for the training.

  17. Optimization of drug-drug interaction alert rules in a pediatric hospital's electronic health record system using a visual analytics dashboard.

    Science.gov (United States)

    Simpao, Allan F; Ahumada, Luis M; Desai, Bimal R; Bonafide, Christopher P; Gálvez, Jorge A; Rehman, Mohamed A; Jawad, Abbas F; Palma, Krisha L; Shelov, Eric D

    2015-03-01

    To develop and evaluate an electronic dashboard of hospital-wide electronic health record medication alerts for an alert fatigue reduction quality improvement project. We used visual analytics software to develop the dashboard. We collaborated with the hospital-wide Clinical Decision Support committee to perform three interventions successively deactivating clinically irrelevant drug-drug interaction (DDI) alert rules. We analyzed the impact of the interventions on care providers' and pharmacists' alert and override rates using an interrupted time series framework with piecewise regression. We evaluated 2 391 880 medication alerts between January 31, 2011 and January 26, 2014. For pharmacists, the median alert rate prior to the first DDI deactivation was 58.74 alerts/100 orders (IQR 54.98-60.48) and 25.11 alerts/100 orders (IQR 23.45-26.57) following the three interventions (pdashboard facilitated safe rapid-cycle reductions in alert burden that were temporally associated with lower pharmacist override rates in a subgroup of DDIs not directly affected by the interventions; meanwhile, the pharmacists' frequency of selecting the 'cancel' option increased. We hypothesize that reducing the alert burden enabled pharmacists to devote more attention to clinically relevant alerts. © The Author 2014. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Effect of Oral Contraceptives, Menstrual Phase and Conditions on Alertness, Performance, and Rhythms in Sleep Deprived Women

    National Research Council Canada - National Science Library

    Badia, Pietro

    1996-01-01

    During our first year of funding, we tested the effects of caffeine, bright light, and placebo treatments on alertness, performance, mood, melatonin, and body temperature during 48 hr of sleep deprivation...

  19. Volcanic Alert System (VAS) developed during the (2011-2013) El Hierro (Canary Islands) volcanic process

    Science.gov (United States)

    Ortiz, Ramon; Berrocoso, Manuel; Marrero, Jose Manuel; Fernandez-Ros, Alberto; Prates, Gonçalo; De la Cruz-Reyna, Servando; Garcia, Alicia

    2014-05-01

    In volcanic areas with long repose periods (as El Hierro), recently installed monitoring networks offer no instrumental record of past eruptions nor experience in handling a volcanic crisis. Both conditions, uncertainty and inexperience, contribute to make the communication of hazard more difficult. In fact, in the initial phases of the unrest at El Hierro, the perception of volcanic risk was somewhat distorted, as even relatively low volcanic hazards caused a high political impact. The need of a Volcanic Alert System became then evident. In general, the Volcanic Alert System is comprised of the monitoring network, the software tools for the analysis of the observables, the management of the Volcanic Activity Level, and the assessment of the threat. The Volcanic Alert System presented here places special emphasis on phenomena associated to moderate eruptions, as well as on volcano-tectonic earthquakes and landslides, which in some cases, as in El Hierro, may be more destructive than an eruption itself. As part of the Volcanic Alert System, we introduce here the Volcanic Activity Level which continuously applies a routine analysis of monitoring data (particularly seismic and deformation data) to detect data trend changes or monitoring network failures. The data trend changes are quantified according to the Failure Forecast Method (FFM). When data changes and/or malfunctions are detected, by an automated watchdog, warnings are automatically issued to the Monitoring Scientific Team. Changes in the data patterns are then translated by the Monitoring Scientific Team into a simple Volcanic Activity Level, that is easy to use and understand by the scientists and technicians in charge for the technical management of the unrest. The main feature of the Volcanic Activity Level is its objectivity, as it does not depend on expert opinions, which are left to the Scientific Committee, and its capabilities for early detection of precursors. As a consequence of the El Hierro

  20. Alcohol Alert

    Science.gov (United States)

    ... of Alcohol Consumption Alcohol's Effects on the Body Alcohol Use Disorder Fetal Alcohol Exposure Support & Treatment Alcohol Policy Special ... 466 KB] No. 81: Exploring Treatment Options for Alcohol Use Disorders [ PDF - 539K] No. 80: Alcohol and HIV/AIDS: ...

  1. Drug Alert

    African Journals Online (AJOL)

    Persons with a history of severe hypersensitivity to eggs;. 2. Persons with acute febrile illnesses should ... care for c'onditions such as chronic pulmonary and cardiac disease, chronic renal diseases, diabetes mellitus ... Africa and Latin America are used to illustrate how empowerment, democratisation and equity, and the.

  2. Nuclear alerts

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    Anti-nuclear demonstrations against the deployment of new US missiles were held in Nato Europe. As no agreement has yet been reached at the US-Soviet Intermediate Nuclear Forces talks in Geneva, the deployment of nuclear missiles in Europe has started

  3. Firewood Alert

    Science.gov (United States)

    USDA Forest Service, Northeastern Area State and Private Forestry; PA Department of Conservation and Natural Resources; Pennsylvania Department of Agriculture

    2006-01-01

    Help stop the movement of exotic pests. Don't move Firewood! Exotic wood borers like emerald ash borer, Asian Long-horned beetle and Sirex wood wasp threaten Pennsylvania's forestland. Exotic wood boring insects can become established when infested firewood is transported to new areas.

  4. Decreased alertness

    Science.gov (United States)

    ... is due to alcohol intoxication , fainting , or a seizure disorder that has already been diagnosed. People with epilepsy or other seizure disorders should wear a medical ID bracelet or necklace ...

  5. Finite-Fault and Other New Capabilities of CISN ShakeAlert

    Science.gov (United States)

    Boese, M.; Felizardo, C.; Heaton, T. H.; Hudnut, K. W.; Hauksson, E.

    2013-12-01

    Over the past 6 years, scientists at Caltech, UC Berkeley, the Univ. of Southern California, the Univ. of Washington, the US Geological Survey, and ETH Zurich (Switzerland) have developed the 'ShakeAlert' earthquake early warning demonstration system for California and the Pacific Northwest. We have now started to transform this system into a stable end-to-end production system that will be integrated into the daily routine operations of the CISN and PNSN networks. To quickly determine the earthquake magnitude and location, ShakeAlert currently processes and interprets real-time data-streams from several hundred seismic stations within the California Integrated Seismic Network (CISN) and the Pacific Northwest Seismic Network (PNSN). Based on these parameters, the 'UserDisplay' software predicts and displays the arrival and intensity of shaking at a given user site. Real-time ShakeAlert feeds are currently being shared with around 160 individuals, companies, and emergency response organizations to gather feedback about the system performance, to educate potential users about EEW, and to identify needs and applications of EEW in a future operational warning system. To improve the performance during large earthquakes (M>6.5), we have started to develop, implement, and test a number of new algorithms for the ShakeAlert system: the 'FinDer' (Finite Fault Rupture Detector) algorithm provides real-time estimates of locations and extents of finite-fault ruptures from high-frequency seismic data. The 'GPSlip' algorithm estimates the fault slip along these ruptures using high-rate real-time GPS data. And, third, a new type of ground-motion prediction models derived from over 415,000 rupture simulations along active faults in southern California improves MMI intensity predictions for large earthquakes with consideration of finite-fault, rupture directivity, and basin response effects. FinDer and GPSlip are currently being real-time and offline tested in a separate internal

  6. Neural correlates of alerting and orienting impairment in multiple sclerosis patients.

    Directory of Open Access Journals (Sweden)

    Manuel Vázquez-Marrufo

    Full Text Available BACKGROUND: A considerable percentage of multiple sclerosis patients have attentional impairment, but understanding its neurophysiological basis remains a challenge. The Attention Network Test allows 3 attentional networks to be studied. Previous behavioural studies using this test have shown that the alerting network is impaired in multiple sclerosis. The aim of this study was to identify neurophysiological indexes of the attention impairment in relapsing-remitting multiple sclerosis patients using this test. RESULTS: After general slowing had been removed in patients group to isolate the effects of each condition, some behavioral differences between them were obtained. About Contingent Negative Variation, a statistically significant decrement were found in the amplitude for Central and Spatial Cue Conditions for patient group (p<0.05. ANOVAs showed for the patient group a significant latency delay for P1 and N1 components (p<0.05 and a decrease of P3 amplitude for congruent and incongruent stimuli (p<0.01. With regard to correlation analysis, PASAT-3s and SDMT showed significant correlations with behavioral measures of the Attention Network Test (p<0.01 and an ERP parameter (CNV amplitude. CONCLUSIONS: Behavioral data are highly correlated with the neuropsychological scores and show that the alerting and orienting mechanisms in the patient group were impaired. Reduced amplitude for the Contingent Negative Variation in the patient group suggests that this component could be a physiological marker related to the alerting and orienting impairment in relapsing-remitting multiple sclerosis. P1 and N1 delayed latencies are evidence of the demyelination process that causes impairment in the first steps of the visual sensory processing. Lastly, P3 amplitude shows a general decrease for the pathological group probably indexing a more central impairment. These results suggest that the Attention Network Test give evidence of multiple levels of attention

  7. Augmented real-time navigation with critical structure proximity alerts for endoscopic skull base surgery.

    Science.gov (United States)

    Dixon, Benjamin J; Daly, Michael J; Chan, Harley; Vescan, Allan; Witterick, Ian J; Irish, Jonathan C

    2014-04-01

    Image-guided surgery (IGS) systems are frequently utilized during cranial base surgery to aid in orientation and facilitate targeted surgery. We wished to assess the performance of our recently developed localized intraoperative virtual endoscopy (LIVE)-IGS prototype in a preclinical setting prior to deployment in the operating room. This system combines real-time ablative instrument tracking, critical structure proximity alerts, three-dimensional virtual endoscopic views, and intraoperative cone-beam computed tomographic image updates. Randomized-controlled trial plus qualitative analysis. Skull base procedures were performed on 14 cadaver specimens by seven fellowship-trained skull base surgeons. Each subject performed two endoscopic transclival approaches; one with LIVE-IGS and one using a conventional IGS system in random order. National Aeronautics and Space Administration Task Load Index (NASA-TLX) scores were documented for each dissection, and a semistructured interview was recorded for qualitative assessment. The NASA-TLX scores for mental demand, effort, and frustration were significantly reduced with the LIVE-IGS system in comparison to conventional navigation (P < .05). The system interface was judged to be intuitive and most useful when there was a combination of high spatial demand, reduced or absent surface landmarks, and proximity to critical structures. The development of auditory icons for proximity alerts during the trial better informed the surgeon while limiting distraction. The LIVE-IGS system provided accurate, intuitive, and dynamic feedback to the operating surgeon. Further refinements to proximity alerts and visualization settings will enhance orientation while limiting distraction. The system is currently being deployed in a prospective clinical trial in skull base surgery. © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  8. Randomized Trial of Intelligent Sensor System for Early Illness Alerts in Senior Housing.

    Science.gov (United States)

    Rantz, Marilyn; Phillips, Lorraine J; Galambos, Colleen; Lane, Kari; Alexander, Gregory L; Despins, Laurel; Koopman, Richelle J; Skubic, Marjorie; Hicks, Lanis; Miller, Steven; Craver, Andy; Harris, Bradford H; Deroche, Chelsea B

    2017-10-01

    Measure the clinical effectiveness and cost effectiveness of using sensor data from an environmentally embedded sensor system for early illness recognition. This sensor system has demonstrated in pilot studies to detect changes in function and in chronic diseases or acute illnesses on average 10 days to 2 weeks before usual assessment methods or self-reports of illness. Prospective intervention study in 13 assisted living (AL) communities of 171 residents randomly assigned to intervention (n=86) or comparison group (n=85) receiving usual care. Intervention participants lived with the sensor system an average of one year. Continuous data collected 24 hours/7 days a week from motion sensors to measure overall activity, an under mattress bed sensor to capture respiration, pulse, and restlessness as people sleep, and a gait sensor that continuously measures gait speed, stride length and time, and automatically assess for increasing fall risk as the person walks around the apartment. Continuously running computer algorithms are applied to the sensor data and send health alerts to staff when there are changes in sensor data patterns. The randomized comparison group functionally declined more rapidly than the intervention group. Walking speed and several measures from GaitRite, velocity, step length left and right, stride length left and right, and the fall risk measure of functional ambulation profile (FAP) all had clinically significant changes. The walking speed increase (worse) and velocity decline (worse) of 0.073 m/s for comparison group exceeded 0.05 m/s, a value considered to be a minimum clinically important difference. No differences were measured in health care costs. These findings demonstrate that sensor data with health alerts and fall alerts sent to AL nursing staff can be an effective strategy to detect and intervene in early signs of illness or functional decline. Copyright © 2017 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published

  9. Framework to Define Structure and Boundaries of Complex Health Intervention Systems: The ALERT Project

    Directory of Open Access Journals (Sweden)

    Elena Boriani

    2017-07-01

    Full Text Available Health intervention systems are complex and subject to multiple variables in different phases of implementation. This constitutes a concrete challenge for the application of translational science in real life. Complex systems as health-oriented interventions call for interdisciplinary approaches with carefully defined system boundaries. Exploring individual components of such systems from different viewpoints gives a wide overview and helps to understand the elements and the relationships that drive actions and consequences within the system. In this study, we present an application and assessment of a framework with focus on systems and system boundaries of interdisciplinary projects. As an example on how to apply our framework, we analyzed ALERT [an integrated sensors and biosensors’ system (BEST aimed at monitoring the quality, health, and traceability of the chain of the bovine milk], a multidisciplinary and interdisciplinary project based on the application of measurable biomarkers at strategic points of the milk chain for improved food security (including safety, human, and ecosystem health (1. In fact, the European food safety framework calls for science-based support to the primary producers’ mandate for legal, scientific, and ethical responsibility in food supply. Because of its multidisciplinary and interdisciplinary approach involving human, animal, and ecosystem health, ALERT can be considered as a One Health project. Within the ALERT context, we identified the need to take into account the main actors, interactions, and relationships of stakeholders to depict a simplified skeleton of the system. The framework can provide elements to highlight how and where to improve the project development when project evaluations are required.

  10. [Major influential factors of the micturition alert device dedicated to neurogenic bladders].

    Science.gov (United States)

    Wang, Jianhuo; Hou, Chunlin; Zheng, Xianyou; Xu, Zhen; Wang, Wanhong; Lin, Haodong

    2008-08-01

    To study major influential factors of the micturition alert device dedicated to neurogenic bladders for the product design and clinical application of the device. One ferrite permanent magnet with thickness and diameter of 3 mm and 10 mm, respectively, and three NdFeB permanent magnets with the thickness of 3 mm and diameter of 10, 15 and 20 mm, respectively, were used. The effects of thickness of the abdominal wall as well as the position and type of permanent magnets on the micturition alert device dedicated to neurogenic bladders were measured in vitro simulated test, when the abdominal wall was set to 2, 3, 4, 5, 6, 7, 8 and 9 cm, respectively, and the position of permanent magnets was 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11 and 12 cm, respectively. The effect of the geomagnetic field on the device was measured under the condition that the thickness of the simulated abdominal wall was set to 2, 3, 4 and 5 cm, respectively, and the position of permanent magnets was 2, 3, 4, 5, 6, 7, 8, 9 and 10 cm, respectively. The value showed in the warning unit was positively correlated with the position of the ferrite permanent magnet only when the thickness of the simulated abdominal wall was 2 cm (r=0.632, P NdFeB permanent magnets was significant (r > 0.622, P NdFeB permanent magnets, but weakened with the increasing thickness of the simulated abdominal wall. The effect of the geomagnetic field was correlated with the exposition of the body, the position of the permanent magnet and the thickness of the abdominal wall. The major influential factors of the micturition alert device dedicated to neurogenic bladder include the magnetism and location of the permanent magnet, the thickness of the abdominal wall and the geomagnetic field. These factors are correlated with and affect each other. Reasonable allocation of these factors may optimize the device.

  11. Optimized molecular resolution of cross-contamination alerts in clinical mycobacteriology laboratories

    Directory of Open Access Journals (Sweden)

    de Viedma Darío

    2008-02-01

    Full Text Available Abstract Background The phenomenon of misdiagnosing tuberculosis (TB by laboratory cross-contamination when culturing Mycobacterium tuberculosis (MTB has been widely reported and it has an obvious clinical, therapeutic and social impact. The final confirmation of a cross-contamination event requires the molecular identification of the same MTB strain cultured from both the potential source of the contamination and from the false-positive candidate. The molecular tool usually applied in this context is IS6110-RFLP which takes a long time to provide an answer, usually longer than is acceptable for microbiologists and clinicians to make decisions. Our purpose in this study is to evaluate a novel PCR-based method, MIRU-VNTR as an alternative to assure a rapid and optimized analysis of cross-contamination alerts. Results MIRU-VNTR was prospectively compared with IS6110-RFLP for clarifying 19 alerts of false positivity from other laboratories. MIRU-VNTR highly correlated with IS6110-RFLP, reduced the response time by 27 days and clarified six alerts unresolved by RFLP. Additionally, MIRU-VNTR revealed complex situations such as contamination events involving polyclonal isolates and a false-positive case due to the simultaneous cross-contamination from two independent sources. Conclusion Unlike standard RFLP-based genotyping, MIRU-VNTR i could help reduce the impact of a false positive diagnosis of TB, ii increased the number of events that could be solved and iii revealed the complexity of some cross-contamination events that could not be dissected by IS6110-RFLP.

  12. Faster but not smarter: effects of caffeine and caffeine withdrawal on alertness and performance.

    Science.gov (United States)

    Rogers, Peter J; Heatherley, Susan V; Mullings, Emma L; Smith, Jessica E

    2013-03-01

    Despite 100 years of psychopharmacological research, the extent to which caffeine consumption benefits human functioning remains unclear. To measure the effects of overnight caffeine abstinence and caffeine administration as a function of level of habitual caffeine consumption. Medium-high (n = 212) and non-low (n = 157) caffeine consumers completed self-report measures and computer-based tasks before (starting at 10:30 AM) and after double-blind treatment with either caffeine (100 mg, then 150 mg) or placebo. The first treatment was given at 11:15 AM and the second at 12:45 PM, with post-treatment measures repeated twice between 1:45 PM and 3:30 PM. Caffeine withdrawal was associated with some detrimental effects at 10:30 AM, and more severe effects, including greater sleepiness, lower mental alertness, and poorer performance on simple reaction time, choice reaction time and recognition memory tasks, later in the afternoon. Caffeine improved these measures in medium-high consumers but, apart from decreasing sleepiness, had little effect on them in non-low consumers. The failure of caffeine to increase mental alertness and improve mental performance in non-low consumers was related to a substantial caffeine-induced increase in anxiety/jitteriness that offset the benefit of decreased sleepiness. Caffeine enhanced physical performance (faster tapping speed and faster simple and choice reaction times) in both medium-high and non-low consumers. While caffeine benefits motor performance and tolerance develops to its tendency to increase anxiety/jitteriness, tolerance to its effects on sleepiness means that frequent consumption fails to enhance mental alertness and mental performance.

  13. Implementation of 'early alert system' area detector at patient from entrance in afterloading brachytherapy

    International Nuclear Information System (INIS)

    Videla Valdebenito, R.

    2001-01-01

    A system of area monitors to detect the involuntary exit of the radiation sources used in low dose rate deferred brachytherapy treatment is being implemented in all facilities in Chile. The first implementation of this system, named 'Early Alert', was 5 years ago as a complement to the administrative procedures and verification measures by the medical physics carried out through visual verifications and by means of portable radiation detectors. This detector of the system should be located preferentially at the exit of the treatment room at a height not smaller than two meters. This has resulted in an increase of facilities safety in this practice. (author) [es

  14. The effect of an electronic "hard-stop" alert on HIV testing rates in the emergency department.

    Science.gov (United States)

    Schnall, Rebecca; Sperling, Jeremy D; Liu, Nan; Green, Robert A; Clark, Sunday; Vawdrey, David K

    2013-01-01

    Use of electronic alerts in clinical practice has had mixed effects on providers' prescribing practices. Little research has explored the use of electronic alerts for improving screening practices. New York City has one of the highest rates of HIV in the United States. Recent New York State legislation requires healthcare providers to offer an HIV test to patients aged 13-64 years during a clinical encounter. Adhering to this requirement is particularly challenging in emergency department (ED) settings, which are frequently overcrowded and under-resourced. The purpose of this study was to evaluate the effect of an electronic "hard-stop" alert on HIV testing rates in the ED. Approximately four months of data were reviewed before and after the implementation of the alert. We found that use of the electronic alert significantly increased documentation of offering an HIV test (O.R. = 267.27, p<0.001) and resulted in a significant increase in HIV testing. Findings from this study add to the current knowledge about the use of electronic alertsfor improving disease screening.

  15. Do e-mail alerts of new research increase knowledge translation? A "Nephrology Now" randomized control trial.

    Science.gov (United States)

    Tanna, Gemini V; Sood, Manish M; Schiff, Jeffrey; Schwartz, Daniel; Naimark, David M

    2011-01-01

    As the volume of medical literature increases exponentially, maintaining current clinical practice is becoming more difficult. Multiple, Internet-based journal clubs and alert services have recently emerged. The purpose of this study is to determine whether the use of the e-mail alert service, Nephrology Now, increases knowledge translation regarding current nephrology literature. Nephrology Now is a nonprofit, monthly e-mail alert service that highlights clinically relevant articles in nephrology. In 2007-2008, the authors randomized 1,683 subscribers into two different groups receiving select intervention articles, and then they used an online survey to assess both groups on their familiarity with the articles and their acquisition of knowledge. Of the randomized subscribers, 803 (47.7%) completed surveys, and the two groups had a similar number of responses (401 and 402, respectively). The authors noted no differences in baseline characteristics between the two groups. Familiarity increased as a result of the Nephrology Now alerts (0.23 ± 0.087 units on a familiarity scale; 95% confidence interval [CI]: 0.06-0.41; P = .007) especially in physicians (multivariate odds ratio 1.83; P = .0002). No detectable improvement in knowledge occurred (0.03 ± 0.083 units on a knowledge scale; 95% CI: -0.13 to 0.20; P = .687). An e-mail alert service of new literature improved a component of knowledge translation--familiarity--but not knowledge acquisition in a large, randomized, international population.

  16. Evaluation of Different Methods for Identification of Structural Alerts Using Chemical Ames Mutagenicity Data Set as a Benchmark.

    Science.gov (United States)

    Yang, Hongbin; Li, Jie; Wu, Zengrui; Li, Weihua; Liu, Guixia; Tang, Yun

    2017-06-19

    Identification of structural alerts for toxicity is useful in drug discovery and other fields such as environmental protection. With structural alerts, researchers can quickly identify potential toxic compounds and learn how to modify them. Hence, it is important to determine structural alerts from a large number of compounds quickly and accurately. There are already many methods reported for identification of structural alerts. However, how to evaluate those methods is a problem. In this paper, we tried to evaluate four of the methods for monosubstructure identification with three indices including accuracy rate, coverage rate, and information gain to compare their advantages and disadvantages. The Kazius' Ames mutagenicity data set was used as the benchmark, and the four methods were MoSS (graph-based), SARpy (fragment-based), and two fingerprint-based methods including Bioalerts and the fingerprint (FP) method we previously used. The results showed that Bioalerts and FP could detect key substructures with high accuracy and coverage rates because they allowed unclosed rings and wildcard atom or bond types. However, they also resulted in redundancy so that their predictive performance was not as good as that of SARpy. SARpy was competitive in predictive performance in both training set and external validation set. These results might be helpful for users to select appropriate methods and further development of methods for identification of structural alerts.

  17. Using an Ongoing Study of Terrestrial Plant Response to Ultraviolet Radiation in Project ALERT

    Science.gov (United States)

    Condon, Estelle; Skiles, J. W.; Seitz, Jeffery C.; Dantoni, Hector L.

    1998-01-01

    The ALERT (Augmented Learning Environment for Renewable Teaching) Project is a cooperative California-based program with two main partners: California State University (CSU) geoscience and education departments and two NASA Centers, the Jet Propulsion Laboratory (JPL) in Pasadena and the Ames Research Center (ARC) in Mountain View. This paper presents an example of how a NASA research effort can be used in the undergraduate classroom. A study, now in the fourth year, subjects test plants to exposures of varying solar ultraviolet (UV) radiation (280 - 340 nm); a full solar UV exposure, a solar UV exposure less about 14% of ambient UV flux, and a UV-blocked regime. This experiment is simple in that only modest amounts of expense are required yet it is elegant since only one variable, UV-flux is involved. The experiment lends itself to teaching several of the Earth Sciences because it uses information from botany, taxonomy, and ecology. Aspects of physics are inherent in the study since portions of the electromagnetic spectrum are studied. Further, since only one of many variables are manipulated, UV flux, the study demonstrates how the scientific method is used in formulating and testing hypotheses. Based on the ALERT experience this summer, this study will be implemented at a CSU campus with the expectation that it will serve as a pedagogical tool and where it will involve students in actual research.

  18. Wet snow hazard for power lines: a forecast and alert system applied in Italy

    Directory of Open Access Journals (Sweden)

    P. Bonelli

    2011-09-01

    Full Text Available Wet snow icing accretion on power lines is a real problem in Italy, causing failures on high and medium voltage power supplies during the cold season. The phenomenon is a process in which many large and local scale variables contribute in a complex way and not completely understood. A numerical weather forecast can be used to select areas where wet snow accretion has an high probability of occurring, but a specific accretion model must also be used to estimate the load of an ice sleeve and its hazard. All the information must be carefully selected and shown to the electric grid operator in order to warn him promptly.

    The authors describe a prototype of forecast and alert system, WOLF (Wet snow Overload aLert and Forecast, developed and applied in Italy. The prototype elaborates the output of a numerical weather prediction model, as temperature, precipitation, wind intensity and direction, to determine the areas of potential risk for the power lines. Then an accretion model computes the ice sleeves' load for different conductor diameters. The highest values are selected and displayed on a WEB-GIS application principally devoted to the electric operator, but also to more expert users. Some experimental field campaigns have been conducted to better parameterize the accretion model. Comparisons between real accidents and forecasted icing conditions are presented and discussed.

  19. Wet snow hazard for power lines: a forecast and alert system applied in Italy

    Science.gov (United States)

    Bonelli, P.; Lacavalla, M.; Marcacci, P.; Mariani, G.; Stella, G.

    2011-09-01

    Wet snow icing accretion on power lines is a real problem in Italy, causing failures on high and medium voltage power supplies during the cold season. The phenomenon is a process in which many large and local scale variables contribute in a complex way and not completely understood. A numerical weather forecast can be used to select areas where wet snow accretion has an high probability of occurring, but a specific accretion model must also be used to estimate the load of an ice sleeve and its hazard. All the information must be carefully selected and shown to the electric grid operator in order to warn him promptly. The authors describe a prototype of forecast and alert system, WOLF (Wet snow Overload aLert and Forecast), developed and applied in Italy. The prototype elaborates the output of a numerical weather prediction model, as temperature, precipitation, wind intensity and direction, to determine the areas of potential risk for the power lines. Then an accretion model computes the ice sleeves' load for different conductor diameters. The highest values are selected and displayed on a WEB-GIS application principally devoted to the electric operator, but also to more expert users. Some experimental field campaigns have been conducted to better parameterize the accretion model. Comparisons between real accidents and forecasted icing conditions are presented and discussed.

  20. Pattern recognition applied to infrared images for early alerts in fog

    Science.gov (United States)

    Boucher, Vincent; Marchetti, Mario; Dumoulin, Jean; Cord, Aurélien

    2014-09-01

    Fog conditions are the cause of severe car accidents in western countries because of the poor induced visibility. Its forecast and intensity are still very difficult to predict by weather services. Infrared cameras allow to detect and to identify objects in fog while visibility is too low for eye detection. Over the past years, the implementation of cost effective infrared cameras on some vehicles has enabled such detection. On the other hand pattern recognition algorithms based on Canny filters and Hough transformation are a common tool applied to images. Based on these facts, a joint research program between IFSTTAR and Cerema has been developed to study the benefit of infrared images obtained in a fog tunnel during its natural dissipation. Pattern recognition algorithms have been applied, specifically on road signs which shape is usually associated to a specific meaning (circular for a speed limit, triangle for an alert, …). It has been shown that road signs were detected early enough in images, with respect to images in the visible spectrum, to trigger useful alerts for Advanced Driver Assistance Systems.