WorldWideScience

Sample records for techniques transmission electron

  1. Nanostructured PLD-grown gadolinia doped ceria: Chemical and structural characterization by transmission electron microscopy techniques

    DEFF Research Database (Denmark)

    Rodrigo, Katarzyna Agnieszka; Wang, Hsiang-Jen; Heiroth, Sebastian

    2011-01-01

    The morphology as well as the spatially resolved elemental and chemical characterization of 10 mol% gadolinia doped ceria (CGO10) structures prepared by pulsed laser deposition (PLD) technique are investigated by scanning transmission electron microscopy accompanied with electron energy loss...... spectroscopy and energy dispersive X-ray spectroscopy. A dense, columnar and structurally inhomogeneous CGO10 film, i.e. exhibiting grain size refinement across the film thickness, is obtained in the deposition process. The cerium M4,5 edges, used to monitor the local electronic structure of the grains...

  2. New Technique for Successful Thermal Barrier Coating Specimen Preparation for Transmission Electron Microscopy.

    Science.gov (United States)

    Brickey; Lee

    2000-05-01

    Reliability of thermal barrier coatings (TBC) hinges on the adhesion of a thermally grown oxide scale to an insulative ceramic topcoat and an underlying metallic bondcoat. The width of the scale and its interfaces makes transmission electron microscopy (TEM) an appropriate tool for its analysis. However, specimen preparation has proven to be a challenging obstacle leading to a dearth of TEM research on TBCs. A new approach to cross-section TBC TEM specimen preparation is described. The principal advantages of this technique are reproducibility, reduced specimen damage, and time savings resulting from decreased ion milling. This technique has been successfully applied to numerous TBC specimens with various thermal histories.

  3. Conventional transmission electron microscopy.

    Science.gov (United States)

    Winey, Mark; Meehl, Janet B; O'Toole, Eileen T; Giddings, Thomas H

    2014-02-01

    Researchers have used transmission electron microscopy (TEM) to make contributions to cell biology for well over 50 years, and TEM continues to be an important technology in our field. We briefly present for the neophyte the components of a TEM-based study, beginning with sample preparation through imaging of the samples. We point out the limitations of TEM and issues to be considered during experimental design. Advanced electron microscopy techniques are listed as well. Finally, we point potential new users of TEM to resources to help launch their project.

  4. Closer to the native state. Critical evaluation of cryo-techniques for Transmission Electron Microscopy: preparation of biological samples.

    Science.gov (United States)

    Mielanczyk, Lukasz; Matysiak, Natalia; Michalski, Marek; Buldak, Rafal; Wojnicz, Romuald

    2014-01-01

    Over the years Transmission Electron Microscopy (TEM) has evolved into a powerful technique for the structural analysis of cells and tissues at various levels of resolution. However, optimal sample preservation is required to achieve results consistent with reality. During the last few decades, conventional preparation methods have provided most of the knowledge about the ultrastructure of organelles, cells and tissues. Nevertheless, some artefacts can be introduced at all stagesofstandard electron microscopy preparation technique. Instead, rapid freezing techniques preserve biological specimens as close as possible to the native state. Our review focuses on different cryo-preparation approaches, starting from vitrification methods dependent on sample size. Afterwards, we discuss Cryo-Electron Microscopy Of VItreous Sections (CEMOVIS) and the main difficulties associated with this technique. Cryo-Focused Ion Beam (cryo-FIB) is described as a potential alternative for CEMOVIS. Another post-processing route for vitrified samples is freeze substitution and embedding in resin for structural analysis or immunolocalization analysis. Cryo-sectioning according to Tokuyasu is a technique dedicated to high efficiency immunogold labelling. Finally, we introduce hybrid techniques, which combine advantages of primary techniques originally dedicated to different approaches. Hybrid approaches permit to perform the study of difficult-to-fix samples and antigens or help optimize the sample preparation protocol for the integrated Laser and Electron Microscopy (iLEM) technique.

  5. Technique for preparation of transmission electron microscope specimens from wire samples of Al and Al-Al2O3 alloys

    DEFF Research Database (Denmark)

    Lindbo, Jørgen

    1966-01-01

    A technique for thinning 1 mm wire samples of aluminium and aluminium-alumina alloys for transmission electron microscopy is described. The essential feature of the technique, which involves spark machining and electropolishing in a polytetrafluoroethylene holder followed by chemical polishing...

  6. 3D printed electromagnetic transmission and electronic structures fabricated on a single platform using advanced process integration techniques

    Science.gov (United States)

    Deffenbaugh, Paul Issac

    3D printing has garnered immense attention from many fields including in-office rapid prototyping of mechanical parts, outer-space satellite replication, garage functional firearm manufacture, and NASA rocket engine component fabrication. 3D printing allows increased design flexibility in the fabrication of electronics, microwave circuits and wireless antennas and has reached a level of maturity which allows functional parts to be printed. Much more work is necessary in order to perfect the processes of 3D printed electronics especially in the area of automation. Chapter 1 shows several finished prototypes of 3D printed electronics as well as newly developed techniques in fabrication. Little is known about the RF and microwave properties and applications of the standard materials which have been developed for 3D printing. Measurement of a wide variety of materials over a broad spectrum of frequencies up to 10 GHz using a variety of well-established measurement methods is performed throughout chapter 2. Several types of high frequency RF transmission lines are fabricated and valuable model-matched data is gathered and provided in chapter 3 for future designers' use. Of particular note is a fully 3D printed stripline which was automatically fabricated in one process on one machine. Some core advantages of 3D printing RF/microwave components include rapid manufacturing of complex, dimensionally sensitive circuits (such as antennas and filters which are often iteratively tuned) and the ability to create new devices that cannot be made using standard fabrication techniques. Chapter 4 describes an exemplary fully 3D printed curved inverted-F antenna.

  7. Movies of molecular motions and reactions: the single-molecule, real-time transmission electron microscope imaging technique.

    Science.gov (United States)

    Nakamura, Eiichi

    2013-01-02

    "The truth is, the Science of Nature has been already too long made only a work of the Brain and the Fancy: It is now high time that it should return to the plainness and soundness of Observations on material and obvious things," proudly declared Robert Hooke in his highly successful picture book of microscopic and telescopic images, "Micrographia" in 1665. Hooke's statement has remained true in chemistry, where a considerable work of the brain and the fancy is still necessary. Single-molecule, real-time transmission electron microscope (SMRT-TEM) imaging at an atomic resolution now allows us to learn about molecules simply by watching movies of them. Like any dream come true, the new analytical technique challenged the old common sense of the communities, and offers new research opportunities that are unavailable by conventional methods. With its capacity to visualize the motions and the reactions of individual molecules and molecular clusters, the SMRT-TEM technique will become an indispensable tool in molecular science and the engineering of natural and synthetic substances, as well as in science education. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. [application of the analytical transmission electron microscopy techniques for detection, identification and visualization of localization of nanoparticles of titanium and cerium oxides in mammalian cells].

    Science.gov (United States)

    Shebanova, A S; Bogdanov, A G; Ismagulova, T T; Feofanov, A V; Semenyuk, P I; Muronets, V I; Erokhina, M V; Onishchenko, G E; Kirpichnikov, M P; Shaitan, K V

    2014-01-01

    This work represents the results of the study on applicability of the modern methods of analytical transmission electron microscopy for detection, identification and visualization of localization of nanoparticles of titanium and cerium oxides in A549 cell, human lung adenocarcinoma cell line. A comparative analysis of images of the nanoparticles in the cells obtained in the bright field mode of transmission electron microscopy, under dark-field scanning transmission electron microscopy and high-angle annular dark field scanning transmission electron was performed. For identification of nanoparticles in the cells the analytical techniques, energy-dispersive X-ray spectroscopy and electron energy loss spectroscopy, were compared when used in the mode of obtaining energy spectrum from different particles and element mapping. It was shown that the method for electron tomography is applicable to confirm that nanoparticles are localized in the sample but not coated by contamination. The possibilities and fields of utilizing different techniques for analytical transmission electron microscopy for detection, visualization and identification of nanoparticles in the biological samples are discussed.

  9. Three-Dimensional Transmission Electron Microscopy: A Novel Imaging and Characterization Technique with Nanometer Scale Resolution for Materials Science

    NARCIS (Netherlands)

    Koster, A.J.; Ziese, Ulrike; Verkleij, A.J.; Janssen, A.H.; Jong, K.P. de

    2001-01-01

    Three-dimensional transmission electron microscopy (3D-TEM), effectuated by multiple imaging of a sample combined with image analysis, offers a new approach in materials science to obtain 3D information of complex solid materials. Here we report first-of-its-kind results that have been obtained with

  10. Low voltage transmission electron microscopy of graphene.

    Science.gov (United States)

    Bachmatiuk, Alicja; Zhao, Jiong; Gorantla, Sandeep Madhukar; Martinez, Ignacio Guillermo Gonzalez; Wiedermann, Jerzy; Lee, Changgu; Eckert, Juergen; Rummeli, Mark Hermann

    2015-02-04

    The initial isolation of graphene in 2004 spawned massive interest in this two-dimensional pure sp(2) carbon structure due to its incredible electrical, optical, mechanical, and thermal effects. This in turn led to the rapid development of various characterization tools for graphene. Examples include Raman spectroscopy and scanning tunneling microscopy. However, the one tool with the greatest prowess for characterizing and studying graphene is the transmission electron microscope. State-of-the-art (scanning) transmission electron microscopes enable one to image graphene with atomic resolution, and also to conduct various other characterizations simultaneously. The advent of aberration correctors was timely in that it allowed transmission electron microscopes to operate with reduced acceleration voltages, so that damage to graphene is avoided while still providing atomic resolution. In this comprehensive review, a brief introduction is provided to the technical aspects of transmission electron microscopes relevant to graphene. The reader is then introduced to different specimen preparation techniques for graphene. The different characterization approaches in both transmission electron microscopy and scanning transmission electron microscopy are then discussed, along with the different aspects of electron diffraction and electron energy loss spectroscopy. The use of graphene for other electron microscopy approaches such as in-situ investigations is also presented. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Transmission Electron Microscopy Facility

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Performs basic and applied research in areas of marine geosciences, geophysics, physics, and microbiology using microanalytical techniques.DESCRIPTION: The...

  12. Applications of orientation mapping by scanning and transmission electron microscopy

    DEFF Research Database (Denmark)

    Juul Jensen, D.

    1997-01-01

    The potentials of orientation mapping techniques (in the following referred to as OIM) for studies of thermomechanical processes are analysed. Both transmission electron microscopy (TEM) and scanning electron microscopy (SEM) based OIM techniques are considered. Among the thermomechanical processes...

  13. Proximity Scanning Transmission Electron Microscopy/Spectroscopy

    CERN Document Server

    Hwang, Ing-Shouh

    2016-01-01

    Here a new microscopic method is proposed to image and characterize very thin samples like few-layer materials, organic molecules, and nanostructures with nanometer or sub-nanometer resolution using electron beams of energies lower than 20 eV. The microscopic technique achieves high resolution through the proximity (or near-field) effect, as in scanning tunneling microscopy (STM), while it also allows detection of transmitted electrons for imaging and spectroscopy, as in scanning transmission electron microscopy (STEM). This proximity transmission electron microscopy (PSTEM) does not require any lens to focus the electron beam. It also allows detailed characterization of the interaction of low-energy electron with materials. PSTEM can operate in a way very similar to scanning tunneling microscopy, which provides high-resolution imaging of geometric and electronic structures of the sample surface. In addition, it allows imaging and characterization of the interior structures of the sample based on the detected...

  14. Head sensory organs of Dactylopodola baltica (Macrodasyida, Gastrotricha): a combination of transmission electron microscopical and immunocytochemical techniques.

    Science.gov (United States)

    Liesenjohann, Thilo; Neuhaus, Birger; Schmidt-Rhaesa, Andreas

    2006-08-01

    The anterior and posterior head sensory organs of Dactylopodola baltica (Macrodasyida, Gastrotricha) were investigated by transmission electron microscopy (TEM). In addition, whole individuals were labeled with phalloidin to mark F-actin and with anti-alpha-tubulin antibodies to mark microtubuli and studied with confocal laser scanning microscopy. Immunocytochemistry reveals that the large number of ciliary processes in the anterior head sensory organ contain F-actin; no signal could be detected for alpha-tubulin. Labeling with anti-alpha-tubulin antibodies revealed that the anterior and posterior head sensory organs are innervated by a common stem of nerves from the lateral nerve cords just anterior of the dorsal brain commissure. TEM studies showed that the anterior head sensory organ is composed of one sheath cell and one sensory cell with a single branching cilium that possesses a basal inflated part and regularly arranged ciliary processes. Each ciliary process contains one central microtubule. The posterior head sensory organ consists of at least one pigmented sheath cell and several probably monociliary sensory cells. Each cilium branches into irregularly arranged ciliary processes. These characters are assumed to belong to the ground pattern of the Gastrotricha.

  15. Transmission electron microscopy characterization of nanomaterials

    CERN Document Server

    2014-01-01

    Third volume of a 40volume series on nanoscience and nanotechnology, edited by the renowned scientist Challa S.S.R. Kumar. This handbook gives a comprehensive overview about Transmission electron microscopy characterization of nanomaterials. Modern applications and state-of-the-art techniques are covered and make this volume an essential reading for research scientists in academia and industry.

  16. Transmission Electron Microscope Measures Lattice Parameters

    Science.gov (United States)

    Pike, William T.

    1996-01-01

    Convergent-beam microdiffraction (CBM) in thermionic-emission transmission electron microscope (TEM) is technique for measuring lattice parameters of nanometer-sized specimens of crystalline materials. Lattice parameters determined by use of CBM accurate to within few parts in thousand. Technique developed especially for use in quantifying lattice parameters, and thus strains, in epitaxial mismatched-crystal-lattice multilayer structures in multiple-quantum-well and other advanced semiconductor electronic devices. Ability to determine strains in indivdual layers contributes to understanding of novel electronic behaviors of devices.

  17. Transmission Electron Microscopy Characterization of High-Temperatur Oxidation of Fe-20Cr-5Al Alloy Prepared by Focused Ion Beam Technique

    Directory of Open Access Journals (Sweden)

    Mohammad Dani

    2015-08-01

    Full Text Available The Focused Ion Beam (FIB technique was applied for cross section preparation of the oxidized alloy for Transmission Electron Microscopy (TEM study. Prior to preparation, the specimens of Fe-20Cr-5Al alloy sheet were oxidized in air at 1200 oC for 2 minutes, 10 minutes, 2 hours, and 100 hours. The microstructure and elemental composition of the samples were characterized using TEM equipped with an Energy Dispersive X-Ray Spectroscopy (EDX. The Electron Energy Loss Spectroscopy (EELS was used to determine of the light elements. The TEM investigation reveals remarkable microstructure evolution of the specimens during oxidation which generally exhibit a typical multi-layer structure. The TEM images, however, can provide detailed description about the phases occur after oxidation such as the Tungsten (W and the Gallium (Ga layers on top of the samples obviously formed during FIB preparation, the formation of Al2O3 and Cr2O3 layer, MgAl2O4 spinel, porosity, Zr/Hf/Mg phases or clusters inside the oxide scale. Hence, the FIB technique has been proven to be reliable preparation technique for microstructural and elemental studies of Fe-20Cr-5Al alloy using TEM.

  18. Transmission electron microscopy study of the formation of epitaxial CoSi2/Si (111) by a room-temperature codeposition technique

    Science.gov (United States)

    D'Anterroches, Cecile; Yakupoglu, H. Nejat; Lin, T. L.; Fathauer, R. W.; Grunthaner, P. J.

    1988-01-01

    Co and Si have been codeposited on Si (111) substrates near room temperature in a stoichiometric 1:2 ratio in a molecular beam epitaxy system. Annealing of these deposits yields high-quality single-crystal CoSi2 layers. Transmission electron microscopy has been used to examine as-deposited layers and layers annealed at 300, 500, and 600 C. Single-crystal epitaxial grains of CoSi2 embedded in a matrix of amorphous Co/Si are observed in as-deposited samples, while the layer is predominantly single-crystal, inhomogeneously strained CoSi2 at 300 C. At 600 C, a homogeneously strained single-crystal layer with a high density of pinholes is observed. In contrast to other solid phase epitaxy techniques used to grow CoSi2 on Si (111), no intermediate silicide phases are observed prior to the formation of CoSi2.

  19. The Titan Environmental Transmission Electron Microscope

    DEFF Research Database (Denmark)

    Hansen, Thomas Willum; Wagner, Jakob Birkedal; Jinschek, Jörg R.

    2009-01-01

    electron microscopes (TEMs) were first adapted for use with gases [1]. Such machines are known as environmental transmission electron microscopes or ETEMs and are now in widespread use [2,3]. Although these tools are unique and represent a source of invaluable information, care has to be taken when using...... them and many additional considerations are required when compared to conventional TEM. In particular the parameter space that affects the result of an experiment increases significantly, and it becomes even more important to consider the effect of both electron/solid and electron/gas interactions...... University of Denmark (DTU) provides a unique combination of techniques for studying materials of interest to the catalytic as well as the electronics and other communities [5]. DTU’s ETEM is based on the FEI Titan platform providing ultrahigh microscope stability pushing the imaging resolution into the sub...

  20. Liquid Cell Transmission Electron Microscopy

    Science.gov (United States)

    Liao, Hong-Gang; Zheng, Haimei

    2016-05-01

    Liquid cell transmission electron microscopy (TEM) has attracted significant interest in recent years. With nanofabricated liquid cells, it has been possible to image through liquids using TEM with subnanometer resolution, and many previously unseen materials dynamics have been revealed. Liquid cell TEM has been applied to many areas of research, ranging from chemistry to physics, materials science, and biology. So far, topics of study include nanoparticle growth and assembly, electrochemical deposition and lithiation for batteries, tracking and manipulation of nanoparticles, catalysis, and imaging of biological materials. In this article, we first review the development of liquid cell TEM and then highlight progress in various areas of research. In the study of nanoparticle growth, the electron beam can serve both as the illumination source for imaging and as the input energy for reactions. However, many other research topics require the control of electron beam effects to minimize electron beam damage. We discuss efforts to understand electron beam-liquid matter interactions. Finally, we provide a perspective on future challenges and opportunities in liquid cell TEM.

  1. Transmission electron microscopy in micro-nanoelectronics

    CERN Document Server

    Claverie, Alain

    2013-01-01

    Today, the availability of bright and highly coherent electron sources and sensitive detectors has radically changed the type and quality of the information which can be obtained by transmission electron microscopy (TEM). TEMs are now present in large numbers not only in academia, but also in industrial research centers and fabs.This book presents in a simple and practical way the new quantitative techniques based on TEM which have recently been invented or developed to address most of the main challenging issues scientists and process engineers have to face to develop or optimize sem

  2. Transmission electron microscopy of mercury metal

    KAUST Repository

    Anjum, Dalaver H.

    2016-03-28

    Summary: Transmission electron microcopy (TEM) analysis of liquid metals, especially mercury (Hg), is difficult to carry out because their specimen preparation poses a daunting task due to the unique surface properties of these metals. This paper reports a cryoTEM study on Hg using a novel specimen preparation technique. Hg metal is mixed with water using sonication and quenched in liquid ethane cryogen. This technique permits research into the morphological, phase and structural properties of Hg at nanoscale dimensions. © 2016 Royal Microscopical Society.

  3. Transmission Electron Microscopy and Diffractometry of Materials

    CERN Document Server

    Fultz, Brent

    2013-01-01

    This book explains concepts of transmission electron microscopy (TEM) and x-ray diffractometry (XRD) that are important for the characterization of materials. The fourth edition adds important new techniques of TEM such as electron tomography, nanobeam diffraction, and geometric phase analysis. A new chapter on neutron scattering completes the trio of x-ray, electron and neutron diffraction. All chapters were updated and revised for clarity. The book explains the fundamentals of how waves and wavefunctions interact with atoms in solids, and the similarities and differences of using x-rays, electrons, or neutrons for diffraction measurements. Diffraction effects of crystalline order, defects, and disorder in materials are explained in detail. Both practical and theoretical issues are covered. The book can be used in an introductory-level or advanced-level course, since sections are identified by difficulty. Each chapter includes a set of problems to illustrate principles, and the extensive Appendix includes la...

  4. Electronic waste recycling techniques

    CERN Document Server

    Bernardes, Andréa

    2015-01-01

    This book presents an overview of the characterization of electronic waste. In addition, processing techniques for the recovery of metals, polymers and ceramics are described. This book serves as a source of information and as an educational technical reference for practicing scientists and engineers, as well as for students.

  5. Characterization of nanomaterials with transmission electron microscopy

    KAUST Repository

    Anjum, Dalaver H.

    2016-08-01

    The field of nanotechnology is about research and development on materials whose at least one dimension is in the range of 1 to 100 nanometers. In recent years, the research activity for developing nano-materials has grown exponentially owing to the fact that they offer better solutions to the challenges faced by various fields such as energy, food, and environment. In this paper, the importance of transmission electron microscopy (TEM) based techniques is demonstrated for investigating the properties of nano-materials. Specifically the nano-materials that are investigated in this report include gold nano-particles (Au-NPs), silver atom-clusters (Ag-ACs), tantalum single-atoms (Ta-SAs), carbon materials functionalized with iron cobalt (Fe-Co) NPs and titania (TiO2) NPs, and platinum loaded Ceria (Pt-CeO2) Nano composite. TEM techniques that are employed to investigate nano-materials include aberration corrected bright-field TEM (BF-TEM), high-angle dark-field scanning TEM (HAADF-STEM), electron energy-loss spectroscopy (EELS), and BF-TEM electron tomography (ET). With the help presented of results in this report, it is proved herein that as many TEM techniques as available in a given instrument are essential for a comprehensive nano-scale analysis of nanomaterials.

  6. Transmission Electron Microscopy Physics of Image Formation

    CERN Document Server

    Kohl, Helmut

    2008-01-01

    Transmission Electron Microscopy: Physics of Image Formation presents the theory of image and contrast formation, and the analytical modes in transmission electron microscopy. The principles of particle and wave optics of electrons are described. Electron-specimen interactions are discussed for evaluating the theory of scattering and phase contrast. Also discussed are the kinematical and dynamical theories of electron diffraction and their applications for crystal-structure analysis and imaging of lattices and their defects. X-ray microanalysis and electron energy-loss spectroscopy are treated as analytical methods. Specimen damage and contamination by electron irradiation limits the resolution for biological and some inorganic specimens. This fifth edition includes discussion of recent progress, especially in the area of aberration correction and energy filtering; moreover, the topics introduced in the fourth edition have been updated. Transmission Electron Microscopy: Physics of Image Formation is written f...

  7. Transmission electron microscope CCD camera

    Science.gov (United States)

    Downing, Kenneth H.

    1999-01-01

    In order to improve the performance of a CCD camera on a high voltage electron microscope, an electron decelerator is inserted between the microscope column and the CCD. This arrangement optimizes the interaction of the electron beam with the scintillator of the CCD camera while retaining optimization of the microscope optics and of the interaction of the beam with the specimen. Changing the electron beam energy between the specimen and camera allows both to be optimized.

  8. In situ nanoindentation in a transmission electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Minor, Andrew M. [Univ. of California, Berkeley, CA (United States)

    2002-01-01

    This dissertation presents the development of the novel mechanical testing technique of in situ nanoindentation in a transmission electron microscope (TEM). This technique makes it possible to simultaneously observe and quantify the mechanical behavior of nano-scale volumes of solids.

  9. Transmission electron microscopy of composites

    Science.gov (United States)

    Pirouz, P.; Farmer, S. C.; Ernst, F.; Chung, J.

    1988-01-01

    Since interphase-interfaces are often both the structurally weakest and chemically least stable regions of a composite material, they are critical determinants of such macrostructural characteristics as tensile strength and fracture toughness. Attention is presently given to the use of TEM for the study of interfaces between dissimilar materials; electron-diffraction, analytical, and high-resolution forms of TEM are employed, for the cases of both structural and semiconductor composites. The materials studied are SiC/Si, GaP/Si, and SiC fiber- and whisker-reinforced Si3N4.

  10. Sunrise over Mars - electronic transmission

    Science.gov (United States)

    1976-01-01

    Caption: 'Taken during the Viking Orbiter 1's 40th revolution of Mars, this electronically transmitted image shows sunrise over the tributary canyons of a high plateau region. The white areas are bright clouds of water ice.' As the sun rises over Noctis Labryinthus (the labyrinth of the night), bright clouds of water ice can be observed in and around the tributary canyons of this high plateau region of Mars. This color composite image, reconstructed from three individual black and white frames taken through violet, green, and orange filters, vividly shows the distribution of the clouds against the rust colored background of this Martian desert. The picture was reconstructed by JPL's Image Processing Laboratory using in-flight calibration data to correct the color balance. Scientists have puzzled why the clouds cling to the canyon areas and, only in certain areas, spill over onto the plateau surface. One possibility is that water which condensed during the previous afternoon in shaded eastern-facing slopes of the canyon floor is vaporized as the early morning sun falls on those same slopes. The area covered is about 10,000 square kilometers (4000 square miles), centered at 9 degrees South, 95 degrees West, and the large partial crater at lower right is Oudemans. The picture was taken on Viking Orbiter 1's 40th revolution of the planet. Photograph and caption published in Winds of Change, 75th Anniversary NASA publication (pages 108-109), by James Schultz.

  11. ULTRA HIGH POWER TRANSMISSION LINE TECHNIQUES

    Science.gov (United States)

    The ultra-high power transmission line techniques including both failure mechanisms and component design are discussed. Failures resulting from...a waveguide. In view of the many advantages of the low loss mode in circular waveguide for ultra-high power levels, a mode transducer and a two...percent of the peak power of a standard rectangular wave guide. Water cooling is provided for high average power operation. Analysis of mode sup pression

  12. Structure Identification in High-Resolution Transmission Electron Microscopic Images

    DEFF Research Database (Denmark)

    Vestergaard, Jacob Schack; Kling, Jens; Dahl, Anders Bjorholm

    2014-01-01

    A connection between microscopic structure and macroscopic properties is expected for almost all material systems. High-resolution transmission electron microscopy is a technique offering insight into the atomic structure, but the analysis of large image series can be time consuming. The present ...

  13. Isotope analysis in the transmission electron microscope

    CERN Document Server

    Susi, Toma; Argentero, Giacomo; Leuthner, Gregor T; Pennycook, Timothy J; Mangler, Clemens; Meyer, Jannik C; Kotakoski, Jani

    2016-01-01

    The {\\AA}ngstr\\"om-sized probe of the scanning transmission electron microscope can visualize and collect spectra from single atoms. This can unambiguously resolve the chemical structure of materials, but not their isotopic composition. Here we differentiate between two isotopes of the same element by quantifying how likely the energetic imaging electrons are to eject atoms. First, we measure the displacement probability in graphene grown from either $^{12}$C or $^{13}$C and describe the process using a quantum mechanical model of lattice vibrations coupled with density functional theory simulations. We then test our spatial resolution in a mixed sample by ejecting individual atoms from nanoscale areas spanning an interface region that is far from atomically sharp, mapping the isotope concentration with a precision better than 20%. Although we use a scanning instrument, our method should be applicable to any atomic resolution transmission electron microscope and to other low-dimensional materials.

  14. Transmission techniques for 4G systems

    CERN Document Server

    Da Silva, Mario Marques

    2012-01-01

    Fourth Generation (4G) wireless communication systems support current and emergent multimedia services such as mobile TV, social networks and gaming, high-definition TV, video teleconferencing, and messaging services. These systems feature the All-over-IP concept and boast improved quality of service. Several important R&D activities are currently under way in the field of wireless communications for 4G systems, but the coverage is widespread in the literature. Transmission Techniques for 4G Systems presents a compilation of the latest developments in the field of wireless communications for 4

  15. Quantitative Scanning Transmission Electron Microscopy of Electronic and Nanostructured Materials

    Science.gov (United States)

    Yankovich, Andrew B.

    Electronic and nanostructured materials have been investigated using advanced scanning transmission electron microscopy (STEM) techniques. The first topic is the microstructure of Ga and Sb-doped ZnO. Ga-doped ZnO is a candidate transparent conducting oxide material. The microstructure of GZO thin films grown by MBE under different growth conditions and different substrates were examined using various electron microscopy (EM) techniques. The microstructure, prevalent defects, and polarity in these films strongly depend on the growth conditions and substrate. Sb-doped ZnO nanowires have been shown to be the first route to stable p-type ZnO. Using Z-contrast STEM, I have showed that an unusual microstructure of Sb-decorated head-to-head inversion domain boundaries and internal voids contain all the Sb in the nanowires and cause the p-type conduction. InGaN thin films and InGaN / GaN quantum wells (QW) for light emitting diodes are the second topic. Low-dose Z-contrast STEM, PACBED, and EDS on InGaN QW LED structures grown by MOCVD show no evidence for nanoscale composition variations, contradicting previous reports. In addition, a new extended defect in GaN and InGaN was discovered. The defect consists of a faceted pyramid-shaped void that produces a threading dislocation along the [0001] growth direction, and is likely caused by carbon contamination during growth. Non-rigid registration (NRR) and high-precision STEM of nanoparticles is the final topic. NRR is a new image processing technique that corrects distortions arising from the serial nature of STEM acquisition that previously limited the precision of locating atomic columns and counting the number of atoms in images. NRR was used to demonstrate sub-picometer precision in STEM images of single crystal Si and GaN, the best achieved in EM. NRR was used to measure the atomic surface structure of Pt nanoacatalysts and Au nanoparticles, which revealed new bond length variation phenomenon of surface atoms. In

  16. Exploring the environmental transmission electron microscope

    DEFF Research Database (Denmark)

    Wagner, Jakob B.; Cavalca, Filippo; Damsgaard, Christian D.

    2012-01-01

    of the opportunities that the environmental TEM (ETEM) offers when combined with other in situ techniques will be explored, directly in the microscope, by combining electron-based and photon-based techniques and phenomena. In addition, application of adjacent setups using sophisticated transfer methods...

  17. Long distance electron transmission in marine sediment

    DEFF Research Database (Denmark)

    Risgaard-Petersen, Nils; Nielsen, Lars Peter

    processes leads to formation of electrical fields, which modifies ion transport. The local proton producing and proton consuming half reactions induces pH extremes that accelerate dissolution of iron sul-phides and calcium carbonates in anoxic layers and promotes the formation of Mg-calcite and iron oxides...... in the oxic zone. Oxygen seems to be the major electron acceptor in the coupled system, and more than 40% of the oxygen consumption can be driven by long distance electron transmission. The major e-donor is sulfide, which is oxidized to sulfate, and iron sulphides are the major sources for sulfide...

  18. Three-Dimensional Orientation Mapping in the Transmission Electron Microscope

    DEFF Research Database (Denmark)

    Liu, Haihua; Schmidt, Søren; Poulsen, Henning Friis

    2011-01-01

    Over the past decade, efforts have been made to develop nondestructive techniques for three-dimensional (3D) grain-orientation mapping in crystalline materials. 3D x-ray diffraction microscopy and differential-aperture x-ray microscopy can now be used to generate 3D orientation maps with a spatial...... resolution of 200 nanometers (nm). We describe here a nondestructive technique that enables 3D orientation mapping in the transmission electron microscope of mono- and multiphase nanocrystalline materials with a spatial resolution reaching 1 nm. We demonstrate the technique by an experimental study...... of a nanocrystalline aluminum sample and use simulations to validate the principles involved...

  19. Imaging domains in transmission electron microscopy (invited) (abstract)

    Science.gov (United States)

    Mishra, R. K.

    1987-04-01

    Magnetic domain walls and domains inside thin electron transparent specimens of ferromagnetic materials can be imaged using the Fresnel and Focault techniques in a transmission electron microscope. Combined with the diffraction, microstructural and microchemical capabilities of modern microscopes, Lorentz microscopy offers one of the most powerful tools to study structure-property relationships in magnetic materials. In addition, using this technique, it is possible to deduce the local magnetization distribution around inhomogeneities and complex Bloch and Néel walls. Lorentz images can be used to quantitatively measure domain wall thickness and estimate domain wall energy. With modified sample holders and pole pieces, one can study in situ domain wall motion and the interaction of domains with microstructural features such as second phases, grain boundaries, structural defects, etc. All these will be illustrated with examples of Lorentz images from soft and hard magnets with special emphasis on the Nd-Fe-B hard magnets. Finally, the limitations of the Lorentz imaging technique utilizing the deflected electron intensities will be outlined and a new technique which utilizes the phase changes in the electron beam as it passes through the material in a scanning transmission microscope will be reviewed.

  20. TEBAL: Nanosculpting devices with electrons in a transmission electron microscope

    Science.gov (United States)

    Drndic, Marija

    2008-03-01

    Manipulation of matter on the scale of atoms and molecules is an essential part of realizing the potential that nanotechnology has to offer. In this talk I will describe transmission electron beam ablation lithography (TEBAL), a method for fabricating nanostructures and fully integrated devices on silicon nitride membranes by nanosculpting evaporated metal films with electron beams. TEBAL works by controllably exposing materials to an intense and highly focused beam of 200 keV electrons inside the transmission electron microscope (TEM). The effect of electron irradiation can be used to controllably displace or ablate regions of the metal with resolution on the scale of tens of atoms per exposure. In situ TEM imaging of the ablation action with atomic resolution allows for real-time feedback control during fabrication. Specific examples presented here include the fabrication and characterization of nanogaps, nanorings, nanowires with tailored shapes and curvatures, and multi-terminal devices with nanoislands or nanopores between the terminals. These nanostructures are fabricated at precise locations on a chip and seamlessly integrated into large-scale circuitry. I will discuss how the combination of high resolution, geometrical control and yield make TEBAL attractive for many applications including nanoelectronics, superconductivity, nanofluidics and molecular (DNA) translocation studies through nanopore-based transistors. References: 1) M.D. Fischbein and M. Drndic, ``Sub-10 nm Device Fabrication in a Transmission Electron Microscope'', Nano Letters, 7 (5), 1329, 2007. 2) M. D. Fischbein and M. Drndic, ``Nanogaps by direct lithography for high-resolution imaging and electronic characterization of nanostructures'', Applied Physics Letters, 88 (6), 063116, 2006.

  1. Scaling studies with gamma transmission technique

    Energy Technology Data Exchange (ETDEWEB)

    Bjoernstad, Tor; Stamatakis, Emmanuel

    2006-03-15

    A method based on gamma transmission attenuation for study of scaling rates in open tubes has been tested and qualified in laboratory experiments. This is a non-intrusive continuous on-line technique, which requires a gamma-emitting radioactive source and a corresponding gamma detector. Gamma emission with energies larger than 300 keV from a source of {sup 133}Ba and a NaI(Tl) detector has been used in experiments with CaCO{sub 3}{sup -}scaling. The equipment allows for axial tube scanning. Thus, scaling rates and thicknesses along the length of the tube may be measured. Saturation ratios down to SR 1.5 has been tested with good results. The possibility to apply this technique to measure scaling rates also in porous media is evaluated. By optimizing the experimental conditions, scaling thicknesses down to 30 micrometer is feasible in a silicate-packed tube of 1 cm internal diameter. Besides studying induction times and scaling rates, this method is useful for screening of the effect of various scale inhibitors. (author) (tk)

  2. Simultaneous orientation and thickness mapping in transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tyutyunnikov, Dmitry, E-mail: dmitry.tyutyunnikov@uni-ulm.de [Institute for Experimental Physics, University of Ulm, Albert-Einstein-Allee 11, 89081 Ulm (Germany); Burak Özdöl, V. [National Center for Electron Microscopy, MS 72-150 Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Koch, Christoph T. [Institute for Experimental Physics, University of Ulm, Albert-Einstein-Allee 11, 89081 Ulm (Germany)

    2015-03-15

    In this paper we introduce an approach for simultaneous thickness and orientation mapping of crystalline samples by means of transmission electron microscopy. We show that local thickness and orientation values can be extracted from experimental dark-field (DF) image data acquired at different specimen tilts. The method has been implemented to automatically acquire the necessary data and then map thickness and crystal orientation for a given region of interest. We have applied this technique to a specimen prepared from a commercial semiconductor device, containing multiple 22 nm technology transistor structures. The performance and limitations of our method are discussed and compared to those of other techniques available.

  3. Transmission Technique towards Seamless Handover for NGEO Satellite Networks

    Institute of Scientific and Technical Information of China (English)

    Wang LU; Liu Lixiang; Hu Xiaohui

    2011-01-01

    This paper presents a seamless transmission technique for Non-Geostationary Earth Orbit (NGEO) satellite networks.The seamless transmission technique combines the concept of Hop-by-Hop and network coding to alleviate the negative impacts of handovers,high bit error rate,and long delay,and to achieve high throughput and complete delivery in NGEO satellite networks.This network coding algorithm is able to maintain expected small queue size and low decoding latency.Furthermore,the seamless transmission technique applies a novel explicit congestion notification mechanism and can achieve high bandwidth utilization.Various aspects of this seamless transmission technique are evaluated.

  4. Microfluidic system for transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ring, Elisabeth A [ORNL; De Jonge, Niels [ORNL

    2010-01-01

    We present a microfluidic system that maintains liquid flow in a specimen chamber for (scanning) transmission electron microscope ((S)TEM) imaging. The specimen chamber consists of two ultra-thin silicon nitride windows supported by silicon microchips. They are placed in a specimen holder that seals the sample from the vacuum in the electron microscope, and incorporates tubing to and from the sample connected to a syringe pump outside the microscope. Using results obtained from fluorescence microscopy of microspheres flowing through the system, an equation to characterize the liquid flow through the system was calibrated. Gold nanoparticles of diameters of 30 and 100 nm moving in liquid were imaged with a 200 kV STEM. It was concluded that despite strong influences from Brownian motion, and sensitivity to small changes in the depth of the bypass channel, the electron microscopy flow data matched the calculated flow speed within an order of magnitude. The system allows for rapid (within a minute) liquid exchange, which can potentially be used, for example, to investigate the response of specimens, e.g., eukaryotic-, or bacterial cells, to certain stimuli.

  5. Quantitative characterization of electron detectors for transmission electron microscopy.

    Science.gov (United States)

    Ruskin, Rachel S; Yu, Zhiheng; Grigorieff, Nikolaus

    2013-12-01

    A new generation of direct electron detectors for transmission electron microscopy (TEM) promises significant improvement over previous detectors in terms of their modulation transfer function (MTF) and detective quantum efficiency (DQE). However, the performance of these new detectors needs to be carefully monitored in order to optimize imaging conditions and check for degradation over time. We have developed an easy-to-use software tool, FindDQE, to measure MTF and DQE of electron detectors using images of a microscope's built-in beam stop. Using this software, we have determined the DQE curves of four direct electron detectors currently available: the Gatan K2 Summit, the FEI Falcon I and II, and the Direct Electron DE-12, under a variety of total dose and dose rate conditions. We have additionally measured the curves for the Gatan US4000 and TVIPS TemCam-F416 scintillator-based cameras. We compare the results from our new method with published curves. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Deciphering the physics and chemistry of perovskites with transmission electron microscopy

    Science.gov (United States)

    Polking, Mark J.

    2016-03-01

    Perovskite oxides exhibit rich structural complexity and a broad range of functional properties, including ferroelectricity, ferromagnetism, and superconductivity. The development of aberration correction for the transmission electron microscope and concurrent progress in electron spectroscopy, electron holography, and other techniques has fueled rapid progress in the understanding of the physics and chemistry of these materials. New techniques based on the transmission electron microscope are first surveyed, and the applications of these techniques for the study of the structure, chemistry, electrostatics, and dynamics of perovskite oxides are then explored in detail, with a particular focus on ferroelectric materials.

  7. Transmission electron microscopy of unstained hybrid Au nanoparticles capped with PPAA (plasma-poly-allylamine)

    DEFF Research Database (Denmark)

    Gontard, Lionel C.; Fernández, Asunción; Dunin-Borkowski, Rafal E.;

    2014-01-01

    Hybrid (organic shell-inorganic core) nanoparticles have important applications in nanomedicine. Although the inorganic components of hybrid nanoparticles can be characterized readily using conventional transmission electron microscopy (TEM) techniques, the structural and chemical arrangement of ...

  8. Transmission electron microscopic examination of phosphoric acid fuel cell components

    Science.gov (United States)

    Pebler, A.

    1986-01-01

    Transmission electron microscopy (TEM) was used to physically characterize tested and untested phosphoric acid fuel cell (PAFC) components. Those examined included carbon-supported platinum catalysts, carbon backing paper, and Teflon-bonded catalyst layers at various stages of fabrication and after testing in pressurized PAFC's. Applicability of electron diffraction and electron energy loss spectroscopy for identifying the various phases was explored. The discussion focuses on the morphology and size distribution of platinum, the morphology and structural aspects of Teflon in catalyst layers, and the structural evidence of carbon corrosion. Reference is made to other physical characterization techniques where appropriate. A qualitative model of the catalyst layer that emerged from the TEM studies is presented.

  9. Transmission techniques for emergent multicast and broadcast systems

    CERN Document Server

    da Silva, Mario Marques; Dinis, Rui; Souto, Nuno; Silva, Joao Carlos

    2010-01-01

    Describing efficient transmission schemes for broadband wireless systems, Transmission Techniques for Emergent Multicast and Broadcast Systems examines advances in transmission techniques and receiver designs capable of supporting the emergent wireless needs for multimedia broadcast and multicast service (MBMS) requirements. It summarizes the research and development taking place in wireless communications for multimedia MBMS and addresses the means to improved spectral efficiency to allow for increased user bit rate, as well as increased capacity of the digital cellular radio network.The text

  10. Tailoring of electron flow current in magnetically insulated transmission lines

    Directory of Open Access Journals (Sweden)

    J. P. Martin

    2009-03-01

    Full Text Available It is desirable to optimize (minimizing both the inductance and electron flow the magnetically insulated vacuum sections of low impedance pulsed-power drivers. The goal of low inductance is understandable from basic efficiency arguments. The goal of low electron flow results from two observations: (1 flowing electrons generally do not deliver energy to (or even reach most loads, and thus constitute a loss mechanism; (2 energetic electrons deposited in a small area can cause anode damage and anode plasma formation. Low inductance and low electron flow are competing goals; an optimized system requires a balance of the two. While magnetically insulated systems are generally forgiving, there are times when optimization is crucial. For example, in large pulsed-power drivers used to energize high energy density physics loads, the electron flow as a fraction of total current is small, but that flow often reaches the anode in relatively small regions. If the anode temperature becomes high enough to desorb gas, the resulting plasma initiates a gap closure process that can impact system performance. Magnetic-pressure driven (z pinches and material equation of state loads behave like a fixed inductor for much of the drive pulse. It is clear that neither fixed gap nor constant-impedance transmission lines are optimal for driving inductive loads. This work shows a technique for developing the optimal impedance profile for the magnetically insulated section of a high-current driver. Particle-in-cell calculations are used to validate the impedance profiles developed in a radial disk magnetically insulated transmission line geometry. The input parameters are the spacing and location of the minimum gap, the effective load inductance, and the desired electron flow profile. The radial electron flow profiles from these simulations are in good agreement with theoretical predictions when driven at relatively high voltage (i.e., V≥2  MV.

  11. Transmission electron microscopy and diffractometry of materials

    CERN Document Server

    Fultz, Brent

    2001-01-01

    This book teaches graduate students the concepts of trans- mission electron microscopy (TEM) and x-ray diffractometry (XRD) that are important for the characterization of materi- als. It emphasizes themes common to both techniques, such as scattering from atoms and the formation and analysis of dif- fraction patterns. It also describes unique aspects of each technique, especially imaging and spectroscopy in the TEM. The textbook thoroughly develops both introductory and ad- vanced-level material, using over 400 accompanying illustra- tions. Problems are provided at the end of each chapter to reinforce key concepts. Simple citatioins of rules are avoi- ded as much as possible, and both practical and theoretical issues are explained in detail. The book can be used as both an introductory and advanced-level graduate text since sec- tions/chapters are sorted according to difficulty and grou- ped for use in quarter and semester courses on TEM and XRD.

  12. In situ and operando transmission electron microscopy of catalytic materials

    DEFF Research Database (Denmark)

    Crozier, Peter A.; Hansen, Thomas Willum

    2015-01-01

    Catalytic nanomaterials play a major role in chemical conversions and energy transformations. Understanding how materials control and regulate surface reactions is a major objective for fundamental research on heterogeneous catalysts. In situ environmental transmission electron microscopy (ETEM......) is a powerful technique for revealing the atomic structures of materials at elevated temperatures in the presence of reactive gases. This approach can allow the structure-reactivity relations underlying catalyst functionality to be investigated. Thus far, ETEM has been limited by the absence of in situ...

  13. Correction of bubble size distributions from transmission electron microscopy observations

    Energy Technology Data Exchange (ETDEWEB)

    Kirkegaard, P.; Eldrup, M.; Horsewell, A.; Skov Pedersen, J.

    1996-01-01

    Observations by transmission electron microscopy of a high density of gas bubbles in a metal matrix yield a distorted size distribution due to bubble overlap and bubble escape from the surface. A model is described that reconstructs 3-dimensional bubble size distributions from 2-dimensional projections on taking these effects into account. Mathematically, the reconstruction is an ill-posed inverse problem, which is solved by regularization technique. Extensive Monte Carlo simulations support the validity of our model. (au) 1 tab., 32 ills., 32 refs.

  14. Electronic Transmission Properties of Two-Dimensional Quasi-Lattice

    Institute of Scientific and Technical Information of China (English)

    侯志林; 傅秀军; 刘有延

    2002-01-01

    In the framework of the tight binding model, the electronic transmission properties of two-dimensional Penrose lattices with free boundary conditions are studied using the generalized eigenfunction method (Phys. Rev. B 60(1999)13444). The electronic transmission coefficients for Penrose lattices with different sizes and widths are calculated, and the result shows strong energy dependence because of the quasiperiodic structure and quantum coherent effect. Around the Fermi level E = 0, there is an energy region with zero transmission amplitudes,which suggests that the studied systems are insulating. The spatial distributions of several typical electronic states with different transmission coefficients are plotted to display the propagation process.

  15. Nanomaterial datasets to advance tomography in scanning transmission electron microscopy

    CERN Document Server

    Levin, Barnaby D A; Chen, Chien-Chun; Scott, M C; Xu, Rui; Theis, Wolfgang; Jiang, Yi; Yang, Yongsoo; Ophus, Colin; Zhang, Haitao; Ha, Don-Hyung; Wang, Deli; Yu, Yingchao; Abruna, Hector D; Robinson, Richard D; Ercius, Peter; Kourkoutis, Lena F; Miao, Jianwei; Muller, David A; Hovden, Robert

    2016-01-01

    Electron tomography in materials science has flourished with the demand to characterize nanoscale materials in three dimensions (3D). Access to experimental data is vital for developing and validating reconstruction methods that improve resolution and reduce radiation dose requirements. This work presents five high-quality scanning transmission electron microscope (STEM) tomography datasets in order to address the critical need for open access data in this field. The datasets represent the current limits of experimental technique, are of high quality, and contain materials with structural complexity. Included are tomographic series of a hyperbranched Co2P nanocrystal, platinum nanoparticles on a carbon nanofibre imaged over the complete 180{\\deg} tilt range, a platinum nanoparticle and a tungsten needle both imaged at atomic resolution by equal slope tomography, and a through-focal tilt series of PtCu nanoparticles. A volumetric reconstruction from every dataset is provided for comparison and development of p...

  16. Analysis of transmission efficiency of SSRF electron beam transfer lines

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    In this article, the main factors which influence transmission efficiency of the SSRF electron beam transfer lines are described, including physical requirements for magnet system, vacuum system, beam diagnostic system,trajectory correction system, etc. The dynamic simulation calculation and transmission efficiency analysis of the SSRF electron beam transfer lines are presented, and the studies show that the design purpose of efficient beam transmission and injection will be achieved.

  17. Insights into complexation of dissolved organic matter and Al(III) and nanominerals formation in soils under contrasting fertilizations using two-dimensional correlation spectroscopy and high resolution-transmission electron microscopy techniques.

    Science.gov (United States)

    Wen, Yongli; Li, Huan; Xiao, Jian; Wang, Chang; Shen, Qirong; Ran, Wei; He, Xinhua; Zhou, Quansuo; Yu, Guanghui

    2014-09-01

    Understanding the organomineral associations in soils is of great importance. Using two-dimensional correlation spectroscopy (2DCOS) and high resolution-transmission electron microscopy (HRTEM) techniques, this study compared the binding characteristics of organic ligands to Al(III) in dissolved organic matter (DOM) from soils under short-term (3-years) and long-term (22-years) fertilizations. Three fertilization treatments were examined: (i) no fertilization (Control), (ii) chemical nitrogen, phosphorus and potassium (NPK), and (iii) NPK plus swine manure (NPKM). Soil spectra detected by the 2DCOS Fourier transform infrared (FTIR) spectroscopy showed that fertilization modified the binding characteristics of organic ligands to Al(III) in soil DOM at both short- and long- term location sites. The CH deformations in aliphatic groups played an important role in binding to Al(III) but with minor differences among the Control, NPK and NPKM at the short-term site. While at the long-term site both C-O stretching of polysaccharides or polysaccharide-like substances and aliphatic O-H were bound to Al(III) under the Control, whereas only aliphatic O-H, and only polysaccharides and silicates, were bound to Al(III) under NPK and NPKM, respectively. Images from HRTEM demonstrated that crystalline nanominerals, composed of Fe and O, were predominant in soil DOM under NPK, while amorphous nanominerals, predominant in Al, Si, and O, were dominant in soil DOM under Control and NPKM. In conclusion, fertilization strategies, especially under long-term, could affect the binding of organic ligands to Al(III) in soil DOM, which resulted in alterations in the turnover, reactivity, and bioavailability of soil organic matter. Our results demonstrated that the FTIR-2DCOS combined with HRTEM techniques could enhance our understanding in the binding characteristics of DOM to Al(III) and the resulted nanominerals in soils.

  18. Oxidation mechanism of nickel particles studied in an environmental transmission electron microscope

    DEFF Research Database (Denmark)

    Jeangros, Q.; Hansen, Thomas Willum; Wagner, Jakob Birkedal

    2014-01-01

    The oxidation of nickel particles was studied in situ in an environmental transmission electron microscope in 3.2 mbar of O2 between ambient temperature and 600°C. Several different transmission electron microscopy imaging techniques, electron diffraction and electron energy-loss spectroscopy were...... diffusion of Ni2+ along NiO grain boundaries, self-diffusion of Ni2+ ions and vacancies, growth of NiO grains and nucleation of voids at Ni/NiO interfaces. We also observed the formation of transverse cracks in a growing NiO film in situ in the electron microscope....

  19. Transmission electron microscopy physics of image formation and microanalysis

    CERN Document Server

    Reimer, Ludwig

    1993-01-01

    "Transmission Electron Microscopy" presents the theory of image and contrastformation, and the analytical modes in transmission electron microscopy Theprinciples of particle and wave optics of electrons are described Electron-specimen interactions are discussed for evaluating the theory of scattering and phase contrast Also analysed are the kinetical and dynamical theories of electron diffraction and their applications for crystal-structure determination and imaging of lattices and their defects X-ray microanalysis and electron energy-loss spectroscopy are treated as analytical methods The third edition includes a brief discussionof Schottky emission guns, some clarification of minor details, and references to the recent literature

  20. Transmission of electrons through Al2O3 nanocapillaries

    DEFF Research Database (Denmark)

    Milosavljević, A.R.; Jureta, J.J.; Víkor, Gy.;

    2012-01-01

    We investigate transmission of low-energy electrons (250 eV) through insulating AlO nanocapillaries (270 nm diameter and 15 μm length). Kinetic energy distribution of electrons transmitted through the nanocapillaries in the straightforward direction, time dependence of the transmission rate both...... in the straightforward direction and for tilted capillaries and angular distributions of electrons transmitted at the incident energy are presented and discussed....

  1. Transmission Electron Microscopy of Itokawa Regolith Grains

    Science.gov (United States)

    Keller, Lindsay P.; Berger, E. L.

    2013-01-01

    Introduction: In a remarkable engineering achievement, the JAXA space agency successfully recovered the Hayabusa space-craft in June 2010, following a non-optimal encounter and sur-face sampling mission to asteroid 25143 Itokawa. These are the first direct samples ever obtained and returned from the surface of an asteroid. The Hayabusa samples thus present a special op-portunity to directly investigate the evolution of asteroidal sur-faces, from the development of the regolith to the study of the effects of space weathering. Here we report on our preliminary TEM measurements on two Itokawa samples. Methods: We were allocated particles RA-QD02-0125 and RA-QD02-0211. Both particles were embedded in low viscosity epoxy and thin sections were prepared using ultramicrotomy. High resolution images and electron diffraction data were ob-tained using a JEOL 2500SE 200 kV field-emission scanning-transmission electron microscope. Quantitative maps and anal-yses were obtained using a Thermo thin-window energy-dispersive x-ray (EDX) spectrometer. Results: Both particles are olivine-rich (Fo70) with µm-sized inclusions of FeS and have microstructurally complex rims. Par-ticle RA-QD02-0125 is rounded and has numerous sub-µm grains attached to its surface including FeS, albite, olivine, and rare melt droplets. Solar flare tracks have not been observed, but the particle is surrounded by a continuous 50 nm thick, stuctur-ally disordered rim that is compositionally similar to the core of the grain. One of the surface adhering grains is pyrrhotite show-ing a S-depleted rim (8-10 nm thick) with nanophase Fe metal grains (<5 nm) decorating the outermost surface. The pyrrhotite displays a complex superstructure in its core that is absent in the S-depleted rim. Particle RA-QD02-0211 contains solar flare particle tracks (2x109 cm-2) and shows a structurally disordered rim 100 nm thick. The track density corresponds to a surface exposure of 103-104 years based on the track production rate

  2. Transmission Techniques for Relay-Interference Networks

    CERN Document Server

    Mohajer, Soheil; Fragouli, Christina; Tse, David N C

    2008-01-01

    In this paper we study the relay-interference wireless network, in which relay (helper) nodes are to facilitate competing information flows over a wireless network. We examine this in the context of a deterministic wireless interaction model, which eliminates the channel noise and focuses on the signal interactions. Using this model, we show that almost all the known schemes such as interference suppression, interference alignment and interference separation are necessary for relay-interference networks. In addition, we discover a new interference management technique, which we call interference neutralization, which allows for over-the-air interference removal, without the transmitters having complete access the interfering signals. We show that interference separation, suppression, and neutralization arise in a fundamental manner, since we show complete characterizations for special configurations of the relay-interference network.

  3. Origin of the spin-asymmetry of hot-electron transmission in Fe

    NARCIS (Netherlands)

    Banerjee, T.; Lodder, J.C.; Jansen, R.

    2007-01-01

    Using the technique of ballistic electron magnetic microscopy, we have studied the spin-asymmetry of transmission of hot electrons in Fe, for which a recent ab initio calculation has shown that the inelastic lifetime is similar for majority and minority spin. Nevertheless, using a spin-valve structu

  4. Digital processing optical transmission and coherent receiving techniques

    CERN Document Server

    Binh, Le Nguyen

    2013-01-01

    With coherent mixing in the optical domain and processing in the digital domain, advanced receiving techniques employing ultra-high speed sampling rates have progressed tremendously over the last few years. These advances have brought coherent reception systems for lightwave-carried information to the next stage, resulting in ultra-high capacity global internetworking. Digital Processing: Optical Transmission and Coherent Receiving Techniques describes modern coherent receiving techniques for optical transmission and aspects of modern digital optical communications in the most basic lines. The

  5. Transmission electron microscopy physics of image formation and microanalysis

    CERN Document Server

    Reimer, Ludwig

    1997-01-01

    Transmission Electron Microscopy presents the theory of image and contrast formation, and the analytical modes in transmission electron microscopy. The principles of particle and wave optics of electrons are described. Electron-specimen interactions are discussed for evaluating the theory of scattering and phase contrast. Also discussed are the kinematical and dynamical theories of electron diffraction and their applications for crystal-structure analysis and imaging of lattices and their defects. X-ray micronanalysis and electron energy-loss spectroscopy are treated as analytical methods. Specimen damage and contamination by electron irradiation limits the resolution for biological and some inorganic specimens. This fourth edition includes discussion of recent progress, especially in the area of Schottky emission guns, convergent-beam electron diffraction, electron tomography, holography and the high resolution of crystal lattices.

  6. Low-temperature electron microscopy: techniques and protocols.

    Science.gov (United States)

    Fleck, Roland A

    2015-01-01

    Low-temperature electron microscopy endeavors to provide "solidification of a biological specimen by cooling with the aim of minimal displacement of its components through the use of low temperature as a physical fixation strategy" (Steinbrecht and Zierold, Cryotechniques in biological electron microscopy. Springer-Verlag, Berlin, p 293, 1987). The intention is to maintain confidence that the tissue observed retains the morphology and dimensions of the living material while also ensuring soluble cellular components are not displaced. As applied to both scanning and transmission electron microscopy, cryo-electron microscopy is a strategy whereby the application of low-temperature techniques are used to reduce or remove processing artifacts which are commonly encountered in more conventional room temperature electron microscopy techniques which rely heavily on chemical fixation and heavy metal staining. Often, cryo-electron microscopy allows direct observation of specimens, which have not been stained or chemically fixed.

  7. Image Resolution in Scanning Transmission Electron Microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Pennycook, S. J.; Lupini, A.R.

    2008-06-26

    Digital images captured with electron microscopes are corrupted by two fundamental effects: shot noise resulting from electron counting statistics and blur resulting from the nonzero width of the focused electron beam. The generic problem of computationally undoing these effects is called image reconstruction and for decades has proved to be one of the most challenging and important problems in imaging science. This proposal concerned the application of the Pixon method, the highest-performance image-reconstruction algorithm yet devised, to the enhancement of images obtained from the highest-resolution electron microscopes in the world, now in operation at Oak Ridge National Laboratory.

  8. Transmission Electron Microscopy (TEM) investigations of ancient Egyptian cosmetic powders

    Science.gov (United States)

    Deeb, C.; Walter, P.; Castaing, J.; Penhoud, P.; Veyssière, P.

    The processing technologies available during the time of ancient Egypt are of present concern to the field of Archaeology and Egyptology. Materials characterization is the best tool for establishing the processing history of archaeological objects. In this study, transmission electron microscopy (TEM) is used, in addition to other techniques, for phase identification and study of the microstructure and characteristic defect structures in ancient Egyptian cosmetic powders. These powders generally consist of a mix of Pb-containing mineral phases: galena (PbS), cerussite (PbCO3), and phosgenite (Pb2Cl2CO3), among others. Modern materials are fabricated according to recipes found in ancient texts to mimic the processing of ancient times and to compare with the archaeological specimens. In particular, a comparison between the dislocation structures of PbS crystals deformed in the laboratory and PbS from archaeological specimens from the collections of the Louvre Museum is presented .

  9. Characterization of strained semiconductor structures using transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Oezdoel, Vasfi Burak

    2011-08-15

    Today's state-of-the-art semiconductor electronic devices utilize the charge transport within very small volumes of the active device regions. The structural, chemical and optical material properties in these small dimensions can critically affect the performance of these devices. The present thesis is focused on the nanometer scale characterization of the strain state in semiconductor structures using transmission electron microscopy (TEM). Although high-resolution TEM has shown to provide the required accuracy at the nanometer scale, optimization of imaging conditions is necessary for accurate strain measurements. An alternative HRTEM method based on strain mapping on complex-valued exit face wave functions is developed to reduce the artifacts arising from objective lens aberrations. However, a much larger field of view is crucial for mapping strain in the active regions of complex structures like latest generation metal-oxide-semiconductor field-effect transistors (MOSFETs). To overcome this, a complementary approach based on electron holography is proposed. The technique relies on the reconstruction of the phase shifts in the diffracted electron beams from a focal series of dark-field images using recently developed exit-face wave function reconstruction algorithm. Combining high spatial resolution, better than 1 nm, with a field of view of about 1 {mu}m in each dimension, simultaneous strain measurements on the array of MOSFETs are possible. Owing to the much lower electron doses used in holography experiments when compared to conventional quantitative methods, the proposed approach allows to map compositional distribution in electron beam sensitive materials such as InGaN heterostructures without alteration of the original morphology and chemical composition. Moreover, dark-field holography experiments can be performed on thicker specimens than the ones required for high-resolution TEM, which in turn reduces the thin foil relaxation. (orig.)

  10. Nanomaterial datasets to advance tomography in scanning transmission electron microscopy.

    Science.gov (United States)

    Levin, Barnaby D A; Padgett, Elliot; Chen, Chien-Chun; Scott, M C; Xu, Rui; Theis, Wolfgang; Jiang, Yi; Yang, Yongsoo; Ophus, Colin; Zhang, Haitao; Ha, Don-Hyung; Wang, Deli; Yu, Yingchao; Abruña, Hector D; Robinson, Richard D; Ercius, Peter; Kourkoutis, Lena F; Miao, Jianwei; Muller, David A; Hovden, Robert

    2016-06-07

    Electron tomography in materials science has flourished with the demand to characterize nanoscale materials in three dimensions (3D). Access to experimental data is vital for developing and validating reconstruction methods that improve resolution and reduce radiation dose requirements. This work presents five high-quality scanning transmission electron microscope (STEM) tomography datasets in order to address the critical need for open access data in this field. The datasets represent the current limits of experimental technique, are of high quality, and contain materials with structural complexity. Included are tomographic series of a hyperbranched Co2P nanocrystal, platinum nanoparticles on a carbon nanofibre imaged over the complete 180° tilt range, a platinum nanoparticle and a tungsten needle both imaged at atomic resolution by equal slope tomography, and a through-focal tilt series of PtCu nanoparticles. A volumetric reconstruction from every dataset is provided for comparison and development of post-processing and visualization techniques. Researchers interested in creating novel data processing and reconstruction algorithms will now have access to state of the art experimental test data.

  11. Transfer calibration of the transmission of electron-energy spectrometers

    Science.gov (United States)

    Gardner, J. L.; Samson, J. A. R.

    1975-01-01

    Relative intensities of strong peaks in the Hel photoelectron spectra of N2, CO2, CO, and O2 are tabulated. These data were measured with an electron energy analyzer whose relative transmission was calibrated to an accuracy of + or - 5%. The tables are useful for calibrating the transmission of other analyzers for electron energies below 9 eV. Correction for angular distribution effects is discussed.

  12. Transmission electron microscopy in molecular structural biology: A historical survey.

    Science.gov (United States)

    Harris, J Robin

    2015-09-01

    In this personal, historic account of macromolecular transmission electron microscopy (TEM), published data from the 1940s through to recent times is surveyed, within the context of the remarkable progress that has been achieved during this time period. The evolution of present day molecular structural biology is described in relation to the associated biological disciplines. The contribution of numerous electron microscope pioneers to the development of the subject is discussed. The principal techniques for TEM specimen preparation, thin sectioning, metal shadowing, negative staining and plunge-freezing (vitrification) of thin aqueous samples are described, with a selection of published images to emphasise the virtues of each method. The development of digital image analysis and 3D reconstruction is described in detail as applied to electron crystallography and reconstructions from helical structures, 2D membrane crystals as well as single particle 3D reconstruction of icosahedral viruses and macromolecules. The on-going development of new software, algorithms and approaches is highlighted before specific examples of the historical progress of the structural biology of proteins and viruses are presented.

  13. Electron transmission through a class of anthracene aldehyde molecules

    Science.gov (United States)

    Petreska, Irina; Ohanesjan, Vladimir; Pejov, Ljupco; Kocarev, Ljupco

    2016-03-01

    Transmission of electrons via metal-molecule-metal junctions, involving rotor-stator anthracene aldehyde molecules is investigated. Two model barriers having input parameters evaluated from accurate ab initio calculations are proposed and the transmission coefficients are obtained by using the quasiclassical approximation. Transmission coefficients further enter in the integral for the net current, utilizing Simmons' method. Conformational dependence of the tunneling processes is evident and the presence of the side groups enhances the functionality of the future single-molecule based electronic devices.

  14. Microstructural studies of dental amalgams using analytical transmission electron microscopy

    Science.gov (United States)

    Hooghan, Tejpal Kaur

    Dental amalgams have been used for centuries as major restorative materials for decaying teeth. Amalgams are prepared by mixing alloy particles which contain Ag, Sn, and Cu as the major constituent elements with liquid Hg. The study of microstructure is essential in understanding the setting reactions and improving the properties of amalgams. Until the work reported in this dissertation, optical microscopy (OM), scanning electron microscopy (SEM), and x-ray diffractometry (XRD) were used commonly to analyze amalgam microstructures. No previous systematic transmission electron microscopy (TEM) study has been performed due to sample preparation difficulties and composite structure of dental amalgams. The goal of this research was to carry out detailed microstructural and compositional studies of dental amalgams. This was accomplished using the enhanced spatial resolution of the TEM and its associated microanalytical techniques, namely, scanning transmission electron microscopy (STEM), x-ray energy dispersive spectroscopy (XEDS) and micro-microdiffraction (mumuD). A new method was developed for thinning amalgam samples to electron transparency using the "wedge technique." Velvalloy, a low-Cu amalgam, and Tytin, a high-Cu amalgam, were the two amalgams characterized. Velvalloy is composed of a Agsb2Hgsb3\\ (gammasb1)/HgSnsb{7-9}\\ (gammasb2) matrix surrounding unreacted Agsb3Sn (gamma) particles. In addition, hitherto uncharacterized reaction layers between Agsb3Sn(gamma)/Agsb2Hgsb3\\ (gammasb2)\\ and\\ Agsb2Hgsb3\\ (gammasb1)/HgSnsb{7-9}\\ (gammasb2) were observed and analyzed. An Ag-Hg-Sn (betasb1) phase was clearly identified for the first time. In Tytin, the matrix consists of Agsb2Hgsb3\\ (gammasb1) grains. Fine precipitates of Cusb6Snsb5\\ (etasp') are embedded inside the gammasb1 and at the grain boundaries. These precipitates are responsible for the improved creep resistance of Tytin compared to Velvalloy. The additional Cu has completely eliminated the gammasb

  15. Environmental testing techniques for electronics and materials

    CERN Document Server

    Dummer, Geoffrey W A; Fry, D W; Higinbotham, W

    2013-01-01

    Environmental Testing Techniques for Electronics and Materials reviews environmental testing techniques for evaluating the performance of electronic equipment, components, and materials. Environmental test planning, test methods, and instrumentation are described, along with the general environmental conditions under which equipment must operate. This book is comprised of 15 chapters and begins by explaining why environmental testing is necessary and describing the environment in which electronics must operate. The next chapter considers how an environmental test plan is designed; the methods

  16. Environmental Transmission Electron Microscopy in an Aberration-Corrected Environment

    DEFF Research Database (Denmark)

    Hansen, Thomas W.; Wagner, Jakob B.

    2012-01-01

    The increasing use of environmental transmission electron microscopy (ETEM) in materials science provides exciting new possibilities for investigating chemical reactions and understanding both the interaction of fast electrons with gas molecules and the effect of the presence of gas on high-resol...

  17. Electron transmission efficiency of gating-GEM foil for TPC

    Institute of Scientific and Technical Information of China (English)

    XIE Wen-Qing; HUANG Meng; LI Ting; TIAN Yang; LI Yu-Lan; LI Yuan-Jing

    2012-01-01

    In a TPC,ion feedback from the readout detector can cause a space-charge effect and distort the electrical field in the drift region.Gating is one of the effective methods to solve this problem,which can block ions at the expense of losing a certain amount of primary electrons.Compared with the traditional design with a wire structure,gating based on GEM foil is more attractive because of its simplicity.In this paper,the factors influencing the electron transmission efficiency are studied with simulations and experiments.After optimizing all these parameters,an electron transmission efficiency over 80% is obtained.

  18. Scanning transmission electron microscopy imaging and analysis

    CERN Document Server

    Pennycook, Stephen J

    2011-01-01

    Provides the first comprehensive treatment of the physics and applications of this mainstream technique for imaging and analysis at the atomic level Presents applications of STEM in condensed matter physics, materials science, catalysis, and nanoscience Suitable for graduate students learning microscopy, researchers wishing to utilize STEM, as well as for specialists in other areas of microscopy Edited and written by leading researchers and practitioners

  19. Transmission electron microscopy a textbook for materials science

    CERN Document Server

    Williams, David B

    1996-01-01

    Electron microscopy has revolutionized our understanding the extraordinary intellectual demands required of the mi­ of materials by completing the processing-structure-prop­ croscopist in order to do the job properly: crystallography, erties links down to atomistic levels. It now is even possible diffraction, image contrast, inelastic scattering events, and to tailor the microstructure (and meso structure ) of materials spectroscopy. Remember, these used to be fields in them­ to achieve specific sets of properties; the extraordinary abili­ selves. Today, one has to understand the fundamentals ties of modem transmission electron microscopy-TEM­ of all of these areas before one can hope to tackle signifi­ instruments to provide almost all of the structural, phase, cant problems in materials science. TEM is a technique of and crystallographic data allow us to accomplish this feat. characterizing materials down to the atomic limits. It must Therefore, it is obvious that any curriculum in modem mate­ be use...

  20. Transmission electron microscopy physics of image formation and microanalysis

    CERN Document Server

    Reimer, Ludwig

    1989-01-01

    The aim of this book is to present the theory of image and contrast formation and the analytical modes in transmission electron microscopy The principles of particle and wave optics of electrons are described Electron-specimen interactions are discussed for evaluating the theory of scattering and phase contrast Also discussed are the kinematical and dynamical theories of electron diffraction and their applications for crystal structure determination and imaging of lattice defects X-ray microanalysis and energy-loss spectroscopy are treated as analytical methods The second edition includes discussion of recent progress, especially in the areas of energy-loss spectroscopy, crystal-lattice imaging and reflection electron microscopy

  1. Transmission Electron Microscopy Characterization of Helium Bubbles in Aged Plutonium

    Energy Technology Data Exchange (ETDEWEB)

    Schwartz, A J; Wall, M A; Zocco, T G; Blobaum, K M

    2004-11-02

    The self-irradiation damage generated by alpha decay of plutonium results in the formation of lattice defects, helium, and uranium atoms. Over time, microstructural evolution resulting from the self-irradiation may influence the physical and mechanical properties of the material. In order to assess microstructural changes, we have developed and applied procedures for the specimen preparation, handling, and transmission electron microscopy characterization of Pu alloys. These transmission electron microscopy investigations of Pu-Ga alloys ranging in age up to 42-years old reveal the presence of nanometer-sized helium bubbles. The number density of bubbles and the average size have been determined for eight different aged materials.

  2. Image simulations of kinked vortices for transmission electron microscopy

    DEFF Research Database (Denmark)

    Beleggia, Marco; Pozzi, G.; Tonomura, A.

    2010-01-01

    We present an improved model of kinked vortices in high-Tc superconductors suitable for the interpretation of Fresnel or holographic observations carried out with a transmission electron microscope. A kinked vortex is composed of two displaced half-vortices, perpendicular to the film plane...... observations of high-Tc superconducting films, where the Fresnel contrast associated with some vortices showed a dumbbell like appearance. Here, we show that under suitable conditions the JV segment may reveal itself in Fresnel imaging or holographic phase mapping in a transmission electron microscope....

  3. Application of transmission electron tomography for modeling the renal corpuscle.

    Science.gov (United States)

    Cheng, Delfine; Shen, Sylvie; Chen, Xin-Ming; Pollock, Carol; Braet, Filip

    2013-11-01

    Structural alteration to the microanatomical organization of the glomerular filtration barrier results in proteinuria. Conventional transmission electron microscopy is an important diagnostic tool to assess the degree of ultrastructural damage of the corpusclar filtration unit. However, this approach lacks the ability to collect accurate stereological insights in a relative large tissue volume. Transmission electron tomography offers the ability to gather three-dimensional information with relative ease. Therefore, this contribution aims to highlight what electron tomography can bring to the pathologist in this challenging area of diagnostic practice. Kidney tissue was prepared for routine ultrastructural transmission electron microscopy investigation. Three-dimensional data stacks were automatically acquired by tilting semi-thin sections of 270 nm in an angular range of typically -60° to +60° with 1° increment. Subsequently, models of the filtration unit were produced by computer-assisted tracking of structures of interest. This short report illustrates the capability that transmission electron tomography can offer in the fine structure-function assessment of the porous fenestrated glomerular capillary endothelium, the underlying basement membrane and the podocyte filtration slits. Furthermore, this approach allows the generation of morphometric data about size, shape and volume alterations of the kidney's filtration barrier at the nanoscale.

  4. EMI filter techniques in power electronic converters

    Directory of Open Access Journals (Sweden)

    Fredy Edimer Hoyos Velasco

    2012-04-01

    Full Text Available This paper presents the results of EMI reduction techniques applied to power electronic converters. The techniques applied included shielding control and power signals, separating power system references regarding reference for instrumentation and measurement signals, implementing analog filters and configuring an appropriate switch trigger system for electronic power to decrease shifting EMI emissions to the maximum. This paper presents the results before and after applying the techniques to reduce interference. The results were also veryfied by using two real time control strategies rapid control prototyping (RCP.

  5. In situ transmission electron microscopy for magnetic nanostructures

    DEFF Research Database (Denmark)

    Ngo, Duc-The; Kuhn, Luise Theil

    2016-01-01

    Nanomagnetism is a subject of great interest because of both application and fundamental aspects in which understanding of the physical and electromagnetic structure of magnetic nanostructures is essential to explore the magnetic properties. Transmission electron microscopy (TEM) is a powerful tool......-structure correlation. This paper aims at reviewing and discussing in situ TEM magnetic imaging studies, including Lorentz microscopy and electron holography in TEM, applied to the research of magnetic nanostructures....

  6. Nanomaterial datasets to advance tomography in scanning transmission electron microscopy

    OpenAIRE

    Levin, Barnaby D.A.; Padgett, Elliot; Chen, Chien-Chun; Scott, M C; Xu, Rui; Theis, Wolfgang; Jiang, Yi; Yang, Yongsoo; Ophus, Colin; Zhang, Haitao; Ha, Don-Hyung; Wang, Deli; Yu, Yingchao; Abruña, Hector D.; Robinson, Richard D.

    2016-01-01

    Electron tomography in materials science has flourished with the demand to characterize nanoscale materials in three dimensions (3D). Access to experimental data is vital for developing and validating reconstruction methods that improve resolution and reduce radiation dose requirements. This work presents five high-quality scanning transmission electron microscope (STEM) tomography datasets in order to address the critical need for open access data in this field. The datasets represent the cu...

  7. Transmission electron microscopy characterization of photocatalysts for water splitting

    DEFF Research Database (Denmark)

    Cavalca, Filippo; Laursen, Anders Bo; Dahl, Søren

    , it is necessary to understand the fundamentals of their reaction mechanisms, chemical behavior, structure and morphology before, during and after reaction using in situ investigations. Here, we focus on the in situ characterization of photocatalysts [1] in an environmental transmission electron microscope (ETEM...

  8. Microfluidic chip for high resolution transmission electron microscopy

    DEFF Research Database (Denmark)

    2013-01-01

    A Microfluidic chip (100) for transmission electron microscopy has a monolithic body (101) with a front side (102) and a back side (103). The monolithic body (101) comprises an opening (104) on the back side (103) extending in a vertical direction from the back side (103) to a membrane (107...

  9. Highlighting material structure with transmission electron diffraction correlation coefficient maps.

    Science.gov (United States)

    Kiss, Ákos K; Rauch, Edgar F; Lábár, János L

    2016-04-01

    Correlation coefficient maps are constructed by computing the differences between neighboring diffraction patterns collected in a transmission electron microscope in scanning mode. The maps are shown to highlight material structural features like grain boundaries, second phase particles or dislocations. The inclination of the inner crystal interfaces are directly deduced from the resulting contrast.

  10. Metals on BN Studied by High Resolution Transmission Electron Microscopy

    Science.gov (United States)

    Bangert, U.; Zan, R.; Ramasse, Q.; Jalil, Rashid; Riaz, Ibstam; Novoselov, K. S.

    2012-07-01

    Metal impurities, gold and nickel, have been deliberately introduced into boron-nitride (BN) sheets. The structural and topographic properties of doped BN have been studied by aberration corrected scanning transmission electron microscopy (STEM). Analysis revealed that metal atoms cluster preferentially in/on contaminated areas. The metal coverage on BN is almost the same for the same evaporated amount of 1 Å.

  11. Transmission electron microscopy investigation of Bi-2223/Ag tapes

    DEFF Research Database (Denmark)

    Andersen, L.G.; Bals, S.; Tendeloo, G. Van

    2001-01-01

    The microstructure of (Bi,Pb)(2)Sr2Ca2CuOx (Bi-2223) tapes has been investigated by means of transmission electron microscopy (TEM) and high-resolution TEM. The emphasis has been placed on: (1) an examination of the grain morphology and size, (2) grain and colony boundary angles, which are formed...

  12. Electron transmission and quantum current distribution of C70 molecule

    Institute of Scientific and Technical Information of China (English)

    KATSUNORI; Tagami3; MASARU; Tsukada

    2008-01-01

    The characteristics of electron transmission through C70 molecule bridge in which two atomic chain leads are connected to long-axis carbon atoms are investigated theoretically by using tight-binding approach based on the Green’s function with only one π orbital electron per carbon atom. Electron transmission through C70 molecule from the input to the output terminal is obtained. From the spectrum, the switching feature of the electron transmission through C70 is found, and the oscil-lation property based on the quantized level is explained. The quantum current distributions inside C70 molecule bridge are calculated and simulated by the quan-tum current density theory based on Fisher-Lee formula at the energy point E = -0.2 eV, where the transmission spectrum shows a peak. The maximum and the mini-mum bond quantum currents are presented, and the reason why the currents are distributed nonuniformly is explained by the phase difference of the atomic orbits. The result shows that the currents at each atomic site agree with Kirchhoff quan-tum current conservation law.

  13. Statistiscal Experimental Design for Quantitative Atomic Resolution Transmission Electron Microscopy

    NARCIS (Netherlands)

    Van Aert, S.

    2003-01-01

    Statistical experimental design is applied to set up quantitative atomic resolution transmission electron microscopy experiments. In such experiments, observations of the atomic structure of the object under study are always subject to spontaneous fluctuations. As a result of these fluctuations, the

  14. In situ nanoindentation in a transmission electron microscope

    Science.gov (United States)

    Minor, Andrew Murphy

    This dissertation presents the development of the novel mechanical testing technique of in situ nanoindentation in a transmission electron microscope (TEM). This technique makes it possible to simultaneously observe and quantify the mechanical behavior of nano-scale volumes of solids. Chapter 2 details the unique specimen preparation techniques employed to meet the geometrical constraints of the in situ experiments. These techniques include bulk silicon micromachining and the use of a focused ion beam. In section 2.4 a method of voltage-controlled mechanical testing is derived theoretically and proven experimentally. This method enables the quantification of the mechanical behavior during in situ nanoindentation experiments. Three classes of material systems were studied with this new technique: (1) bulk single crystal, (2) a soft thin film on a harder substrate and (3) a hard thin film on a softer substrate. Section 3.2 provides the first direct evidence of dislocation nucleation in single crystal silicon at room temperature. In contrast to the observation of phase transformations during conventional indentation experiments, the unique geometry employed for the in situ experiments resulted in dislocation plasticity. In section 3.3 results from in situ nanoindentation of Al films on Si substrates are presented. These results include the correlation of the microstructural deformation behavior with load vs. displacement data. It is shown that a sharp change in the force-displacement response at the elastic-to-plastic transition signifies the nucleation of dislocations. Additionally, the softening of sub-micron grains with size is observed. Section 3.4 discussed the influence of the substrate on the indentation response of two thin film/substrate systems where the films were harder than the substrate. Amorphous diamond on Si and epitaxial TiN on MgO (001) systems were studied. It was found that the deformation in the harder films was controlled by the deformation in

  15. Security Techniques for the Electronic Health Records.

    Science.gov (United States)

    Kruse, Clemens Scott; Smith, Brenna; Vanderlinden, Hannah; Nealand, Alexandra

    2017-08-01

    The privacy of patients and the security of their information is the most imperative barrier to entry when considering the adoption of electronic health records in the healthcare industry. Considering current legal regulations, this review seeks to analyze and discuss prominent security techniques for healthcare organizations seeking to adopt a secure electronic health records system. Additionally, the researchers sought to establish a foundation for further research for security in the healthcare industry. The researchers utilized the Texas State University Library to gain access to three online databases: PubMed (MEDLINE), CINAHL, and ProQuest Nursing and Allied Health Source. These sources were used to conduct searches on literature concerning security of electronic health records containing several inclusion and exclusion criteria. Researchers collected and analyzed 25 journals and reviews discussing security of electronic health records, 20 of which mentioned specific security methods and techniques. The most frequently mentioned security measures and techniques are categorized into three themes: administrative, physical, and technical safeguards. The sensitive nature of the information contained within electronic health records has prompted the need for advanced security techniques that are able to put these worries at ease. It is imperative for security techniques to cover the vast threats that are present across the three pillars of healthcare.

  16. In situ transmission electron microscopy experimentation of nanostructured materials

    Science.gov (United States)

    Alducin, Diego

    Due to the remarkable mechanical and electrical properties some nanostructured materials possess, it is important to be able to quantitatively characterize how these materials react under different types of stimulus. In situ transmission electron microscopy is a unique technique that allows the user to fully observe and record the crystallographic behavior of such materials undergoing a variety of tests. The crystallographic orientations silver nanowires were mapped in order to understand the structure and facets due to its geometry. Measuring the toughness and yield of the material led us to understand the anisotropic behavior of AgNWs. Depending on whether a load is applied to either a boundary between facets or on a facet will change the mechanical strength of the nanowire. By measuring the resistivity of the this material during deformation has also led us to understand that the intrinsic defects in the crystal structure of nanowires will change the way the material reacts to an electric potential. We have been also able to completely map the crystallographic orientations of very complex geometries of gold nanoparticles and characterize the weak forces involved in the manipulation if these nanoparticles. Finally, the elasticity of MoS2 was tested and found to be exponentially dependent upon the thickness of the nanosheets. However, the resistivity of this material does not seem to be affected by any type of deformation it is subjected to. The complete categorization of how materials interact with external stimulus while comparing the changes observed in its crystal structure is essential to understanding the underlying properties of nanostructured materials, which would not be possible without in situ transmisison electron microscopy experimentation.

  17. Measurements of electron cloud density in the CERN Super Proton Synchrotron with the microwave transmission method

    Directory of Open Access Journals (Sweden)

    S. Federmann

    2011-01-01

    Full Text Available The electron cloud effect can pose severe performance limitations in high-energy particle accelerators as the CERN Super Proton Synchrotron (SPS. Mitigation techniques such as vacuum chamber thin film coatings with low secondary electron yields (SEY<1.3 aim to reduce or even suppress this effect. The microwave transmission method, developed and first applied in 2003 at the SPS, measures the integrated electron cloud density over a long section of an accelerator. This paper summarizes the theory and measurement principle and describes the new SPS microwave transmission setup used to study the electron cloud mitigation of amorphous carbon coated SPS dipole vacuum chambers. Comparative results of carbon coated and bare stainless steel dipole vacuum chambers are given for the beam with nominal LHC 25 ns bunch-to-bunch spacing in the SPS and the electron cloud density is derived.

  18. TRANSMISSION ELECTRON MICROSCOPY OF SEGMENTED POLYURETHANES WITH RUTHENIUM TETROXIDE AS A STAINING AGENT

    Institute of Scientific and Technical Information of China (English)

    XIAO Fengfei; CHEN Shouxi; JIN Yongze; SHI Lianghe; XU Mao

    1991-01-01

    Microphase separation and lamellar structure of segmented polyether- and polyester-polyurethanes have been investigated by means of transmission electron microscopy with the ruthenium tetroxide staining technique. The results show that the RuO4 staining technique is simpler and may give better image contrast than other staining methods for this polymer. Microphase separation and lamellar structure of segmented polyether- and polyester-polyurethanes were directly observed and discussed.

  19. Technique for Measuring Hybrid Electronic Component Reliability

    Energy Technology Data Exchange (ETDEWEB)

    Green, C.C.; Hernandez, C.L.; Hosking, F.M.; Robinson, D.; Rutherford, B.; Uribe, F.

    1999-01-01

    Materials compatibility studies of aged, engineered materials and hardware are critical to understanding and predicting component reliability, particularly for systems with extended stockpile life requirements. Nondestructive testing capabilities for component reliability would significantly enhance lifetime predictions. For example, if the detection of crack propagation through a solder joint can be demonstrated, this technique could be used to develop baseline information to statistically determine solder joint lifelengths. This report will investigate high frequency signal response techniques for nondestructively evaluating the electrical behavior of thick film hybrid transmission lines.

  20. Writing silica structures in liquid with scanning transmission electron microscopy.

    Science.gov (United States)

    van de Put, Marcel W P; Carcouët, Camille C M C; Bomans, Paul H H; Friedrich, Heiner; de Jonge, Niels; Sommerdijk, Nico A J M

    2015-02-04

    Silica nanoparticles are imaged in solution with scanning transmission electron microscopy (STEM) using a liquid cell with silicon nitride (SiN) membrane windows. The STEM images reveal that silica structures are deposited in well-defined patches on the upper SiN membranes upon electron beam irradiation. The thickness of the deposits is linear with the applied electron dose. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) demonstrate that the deposited patches are a result of the merging of the original 20 nm-diameter nanoparticles, and that the related surface roughness depends on the electron dose rate used. Using this approach, sub-micrometer scale structures are written on the SiN in liquid by controlling the electron exposure as function of the lateral position.

  1. Advanced transmission electron microscopy studies in low-energy ion implanted Si Semiconductors; Junctions; Silicon

    CERN Document Server

    Wang, T S

    2002-01-01

    As the dimensions of semiconductor devices shrink down to 0.1 mu m and beyond, low energy ion implantation is required to introduce shallower junctions to match such small devices. In this work, transmission electron microscopy (TEM) is employed to analyse low energy implanted junctions with both structural and chemical analyses. High resolution transmission electron microscopy (HRTEM) has been employed to observe Si crystal damage and amorphization due to low energy B sup + /As sup + ion implantations, and also, defect formation/annihilation during rapid thermal annealing (RTA). The damage effects due to different implant temperatures between 300 deg C and -150 deg C are also discussed. Since knowledge of the distribution of low energy ion implanted dopants in Si is extremely important for semiconductor device processing, energy filtered transmission electron microscopy (EFTEM) has been employed to determine implanted B distributions in Si while Z-contrast imaging and X-ray analytical mapping techniques are ...

  2. Foucault imaging by using non-dedicated transmission electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Taniguchi, Yoshifumi [Science and Medical Systems Business Group, Hitachi High-Technologies Corp., Ichige, Hitachinaka, Ibaraki 312-8504 (Japan); Matsumoto, Hiroaki [Corporate Manufacturing Strategy Group, Hitachi High-Technologies Corp., Ishikawa-cho, Hitachinaka, Ibaraki 312-1991 (Japan); Harada, Ken [Central Research Laboratory, Hitachi Ltd., Hatoyama, Saitama 350-0395 (Japan)

    2012-08-27

    An electron optical system for observing Foucault images was constructed using a conventional transmission electron microscope without any special equipment for Lorentz microscopy. The objective lens was switched off and an electron beam was converged by a condenser optical system to the crossover on the selected area aperture plane. The selected area aperture was used as an objective aperture to select the deflected beam for Foucault mode, and the successive image-forming lenses were controlled for observation of the specimen images. The irradiation area on the specimen was controlled by selecting the appropriate diameter of the condenser aperture.

  3. Foucault imaging by using non-dedicated transmission electron microscope

    Science.gov (United States)

    Taniguchi, Yoshifumi; Matsumoto, Hiroaki; Harada, Ken

    2012-08-01

    An electron optical system for observing Foucault images was constructed using a conventional transmission electron microscope without any special equipment for Lorentz microscopy. The objective lens was switched off and an electron beam was converged by a condenser optical system to the crossover on the selected area aperture plane. The selected area aperture was used as an objective aperture to select the deflected beam for Foucault mode, and the successive image-forming lenses were controlled for observation of the specimen images. The irradiation area on the specimen was controlled by selecting the appropriate diameter of the condenser aperture.

  4. In situ Transmission Electron Microscopy of catalyst sintering

    DEFF Research Database (Denmark)

    DeLaRiva, Andrew T.; Hansen, Thomas Willum; Challa, Sivakumar R.

    2013-01-01

    Recent advancements in the field of electron microscopy, such as aberration correctors, have now been integrated into Environmental Transmission Electron Microscopes (TEMs), making it possible to study the behavior of supported metal catalysts under operating conditions at atomic resolution. Here......, we focus on in situ electron microscopy studies of catalysts that shed light on the mechanistic aspects of catalyst sintering. Catalyst sintering is an important mechanism for activity loss, especially for catalysts that operate at elevated temperatures. Literature from the past decade is reviewed...

  5. High-resolution low-dose scanning transmission electron microscopy.

    Science.gov (United States)

    Buban, James P; Ramasse, Quentin; Gipson, Bryant; Browning, Nigel D; Stahlberg, Henning

    2010-01-01

    During the past two decades instrumentation in scanning transmission electron microscopy (STEM) has pushed toward higher intensity electron probes to increase the signal-to-noise ratio of recorded images. While this is suitable for robust specimens, biological specimens require a much reduced electron dose for high-resolution imaging. We describe here protocols for low-dose STEM image recording with a conventional field-emission gun STEM, while maintaining the high-resolution capability of the instrument. Our findings show that a combination of reduced pixel dwell time and reduced gun current can achieve radiation doses comparable to low-dose TEM.

  6. Transmission and Trapping of Cold Electrons in Water Ice

    DEFF Research Database (Denmark)

    Balog, Richard; Cicman, Peter; Field, David

    2011-01-01

    Experiments are reported that show currents of low energy (“cold”) electrons pass unattenuated through crystalline ice at 135 K for energies between zero and 650 meV, up to the maximum studied film thickness of 430 bilayers, showing negligible apparent trapping. By contrast, both porous amorphous...... ice and compact crystalline ice at 40 K show efficient electron trapping. Ice at intermediate temperatures reveals metastable trapping that decays within a few hundred seconds at 110 K. Our results are the first to demonstrate full transmission of cold electrons in high temperature water ice...

  7. Transmission of electrons inside the cryogenic pumps of ITER injector

    Energy Technology Data Exchange (ETDEWEB)

    Veltri, P., E-mail: pierluigi.veltri@igi.cnr.it; Sartori, E. [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA), Corso Stati Uniti 4, 35127 Padova (Italy)

    2016-02-15

    Large cryogenic pumps are installed in the vessel of large neutral beam injectors (NBIs) used to heat the plasma in nuclear fusion experiments. The operation of such pumps can be compromised by the presence of stray secondary electrons that are generated along the beam path. In this paper, we present a numerical model to analyze the propagation of the electrons inside the pump. The aim of the study is to quantify the power load on the active pump elements, via evaluation of the transmission probabilities across the domain of the pump. These are obtained starting from large datasets of particle trajectories, obtained by numerical means. The transmission probability of the electrons across the domain is calculated for the NBI of the ITER and for its prototype Megavolt ITer Injector and Concept Advancement (MITICA) and the results are discussed.

  8. Transmission of electrons inside the cryogenic pumps of ITER injector.

    Science.gov (United States)

    Veltri, P; Sartori, E

    2016-02-01

    Large cryogenic pumps are installed in the vessel of large neutral beam injectors (NBIs) used to heat the plasma in nuclear fusion experiments. The operation of such pumps can be compromised by the presence of stray secondary electrons that are generated along the beam path. In this paper, we present a numerical model to analyze the propagation of the electrons inside the pump. The aim of the study is to quantify the power load on the active pump elements, via evaluation of the transmission probabilities across the domain of the pump. These are obtained starting from large datasets of particle trajectories, obtained by numerical means. The transmission probability of the electrons across the domain is calculated for the NBI of the ITER and for its prototype Megavolt ITer Injector and Concept Advancement (MITICA) and the results are discussed.

  9. Electronic transmission of three-terminal pyrene molecular bridge

    Institute of Scientific and Technical Information of China (English)

    Wang Li-Guang; Zhang Xiu-Mei; Terence Kin Shun Wong; Katsunori Tagami; Masaru Tsukada

    2009-01-01

    This paper investigates theoretically the electronic transmission spectra of the three terminal pyrene molecular bridge and the quantum current distribution on each bond by the tight-binding model based on nonequilibrium Green's function and the quantum current density approach, in which one π molecular orbital is taken into account per carbon atom when the energy levels and HOMO-LUMO gap are obtained. The transmission spectra show that the electronic transmission of the three terminal pyrene molecular bridge depends obviously on the incident electronic energy and the pyrene eigenencrgy. The symmetrical and oscillation properties of the transmission spectra are illustrated. A novel plus-minus energy switching function is found. The quantum current distribution shows that the loop currents inside the pyrene are induced, and some bond currents are much larger than the input and the output currents. The reasons why the loop currents and the larger bond currents are induced are the phase difference of the atomic orbits and the degeneracy of the molecular orbits. The calculations illustrate that the quantum current distributions are in good agreement with Kirchhoff quantum current conservation law.

  10. Structural studies of glasses by transmission electron microscopy and electron diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Kashchieva, E.P. [University of Chemical Technology and Metallurgy, Sofia (Bulgaria)

    1997-07-01

    The purpose of this work is to present information about the applications of transmission electron microscopy (TEM) and electron diffraction (ED) for structural investigations of glasses. TEM investigations have been carried out on some binary and on a large number of ternary borate-telluride systems where glass-forming oxides, oxides of transitional elements and modified oxides of elements from I, II and III groups in the periodic table, are used as third component. The large experimental data given by TEM method allows the fine classification of the micro-heterogeneities. A special case of micro-heterogeneous structure with technological origin occurs near the boundary between the 2 immiscible liquids obtained at macro-phase separation. TEM was also used for the direct observation of the glass structure and we have studied the nano-scale structure of borate glasses obtained at slow and fast cooling of the melts. The ED possesses advantages for analysis of amorphous thin films or micro-pastilles and it is a very useful technique for study in materials containing simultaneously light and heavy elements. A comparison between the possibilities of the 3 diffraction techniques (X-ray diffraction, neutron diffraction and ED) is presented.

  11. Secondary electron imaging of monolayer materials inside a transmission electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Cretu, Ovidiu, E-mail: cretu.ovidiu@nims.go.jp; Lin, Yung-Chang; Suenaga, Kazutomo [National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba 305-8565 (Japan)

    2015-08-10

    A scanning transmission electron microscope equipped with a backscattered and secondary electron detector is shown capable to image graphene and hexagonal boron nitride monolayers. Secondary electron contrasts of the two lightest monolayer materials are clearly distinguished from the vacuum level. A signal difference between these two materials is attributed to electronic structure differences, which will influence the escape probabilities of the secondary electrons. Our results show that the secondary electron signal can be used to distinguish between the electronic structures of materials with atomic layer sensitivity, enhancing its applicability as a complementary signal in the analytical microscope.

  12. Interaction of electrons with light metal hydrides in the transmission electron microscope.

    Science.gov (United States)

    Wang, Yongming; Wakasugi, Takenobu; Isobe, Shigehito; Hashimoto, Naoyuki; Ohnuki, Somei

    2014-12-01

    Transmission electron microscope (TEM) observation of light metal hydrides is complicated by the instability of these materials under electron irradiation. In this study, the electron kinetic energy dependences of the interactions of incident electrons with lithium, sodium and magnesium hydrides, as well as the constituting element effect on the interactions, were theoretically discussed, and electron irradiation damage to these hydrides was examined using in situ TEM. The results indicate that high incident electron kinetic energy helps alleviate the irradiation damage resulting from inelastic or elastic scattering of the incident electrons in the TEM. Therefore, observations and characterizations of these materials would benefit from increased, instead decreased, TEM operating voltage.

  13. Accurate virus quantitation using a Scanning Transmission Electron Microscopy (STEM) detector in a scanning electron microscope.

    Science.gov (United States)

    Blancett, Candace D; Fetterer, David P; Koistinen, Keith A; Morazzani, Elaine M; Monninger, Mitchell K; Piper, Ashley E; Kuehl, Kathleen A; Kearney, Brian J; Norris, Sarah L; Rossi, Cynthia A; Glass, Pamela J; Sun, Mei G

    2017-10-01

    A method for accurate quantitation of virus particles has long been sought, but a perfect method still eludes the scientific community. Electron Microscopy (EM) quantitation is a valuable technique because it provides direct morphology information and counts of all viral particles, whether or not they are infectious. In the past, EM negative stain quantitation methods have been cited as inaccurate, non-reproducible, and with detection limits that were too high to be useful. To improve accuracy and reproducibility, we have developed a method termed Scanning Transmission Electron Microscopy - Virus Quantitation (STEM-VQ), which simplifies sample preparation and uses a high throughput STEM detector in a Scanning Electron Microscope (SEM) coupled with commercially available software. In this paper, we demonstrate STEM-VQ with an alphavirus stock preparation to present the method's accuracy and reproducibility, including a comparison of STEM-VQ to viral plaque assay and the ViroCyt Virus Counter. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  14. Scanning electron microscopy and transmission electron microscopy study of hot-deformed gamma-TiAl-based alloy microstructure.

    Science.gov (United States)

    Chrapoński, J; Rodak, K

    2006-09-01

    The aim of this work was to assess the changes in the microstructure of hot-deformed specimens made of alloys containing 46-50 at.% Al, 2 at.% Cr and 2 at.% Nb (and alloying additions such as carbon and boron) with the aid of scanning electron microscopy and transmission electron microscopy techniques. After homogenization and heat treatment performed in order to make diverse lamellae thickness, the specimens were compressed at 1000 degrees C. Transmission electron microscopy examinations of specimens after the compression test revealed the presence of heavily deformed areas with a high density of dislocation. Deformation twins were also observed. Dynamically recrystallized grains were revealed. For alloys no. 2 and no. 3, the recovery and recrystallization processes were more extensive than for alloy no. 1.

  15. In situ formation of bismuth nanoparticles through electron-beam irradiation in a transmission electron microscope

    Science.gov (United States)

    Sepulveda-Guzman, S.; Elizondo-Villarreal, N.; Ferrer, D.; Torres-Castro, A.; Gao, X.; Zhou, J. P.; Jose-Yacaman, M.

    2007-08-01

    In this work, bismuth nanoparticles were synthesized when a precursor, sodium bismuthate, was exposed to an electron beam at room temperature in a transmission electron microscope (TEM). The irradiation effects were investigated in situ using selected-area electron diffraction, high-resolution transmission electron microscopy and x-ray energy dispersive spectroscopy. After the electron irradiation, bismuth nanoparticles with a rhombohedral structure and diameter of 6 nm were observed. The average particle size increased with the irradiation time. The electron-induced reduction is attributed to the desorption of oxygen ions. This method offers a one-step route to synthesize bismuth nanoparticles using electron irradiation, and the particle size can be controlled by the irradiation time.

  16. In situ formation of bismuth nanoparticles through electron-beam irradiation in a transmission electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Sepulveda-Guzman, S; Elizondo-Villarreal, N; Ferrer, D; Torres-Castro, A; Gao, X; Zhou, J P; Jose-Yacaman, M [Chemical Engineering Department and Texas Materials Institute, University of Texas at Austin, Austin, TX 78712 (United States)

    2007-08-22

    In this work, bismuth nanoparticles were synthesized when a precursor, sodium bismuthate, was exposed to an electron beam at room temperature in a transmission electron microscope (TEM). The irradiation effects were investigated in situ using selected-area electron diffraction, high-resolution transmission electron microscopy and x-ray energy dispersive spectroscopy. After the electron irradiation, bismuth nanoparticles with a rhombohedral structure and diameter of 6 nm were observed. The average particle size increased with the irradiation time. The electron-induced reduction is attributed to the desorption of oxygen ions. This method offers a one-step route to synthesize bismuth nanoparticles using electron irradiation, and the particle size can be controlled by the irradiation time.

  17. Electron tomography of HEK293T cells using scanning electron microscope-based scanning transmission electron microscopy.

    Science.gov (United States)

    You, Yun-Wen; Chang, Hsun-Yun; Liao, Hua-Yang; Kao, Wei-Lun; Yen, Guo-Ji; Chang, Chi-Jen; Tsai, Meng-Hung; Shyue, Jing-Jong

    2012-10-01

    Based on a scanning electron microscope operated at 30 kV with a homemade specimen holder and a multiangle solid-state detector behind the sample, low-kV scanning transmission electron microscopy (STEM) is presented with subsequent electron tomography for three-dimensional (3D) volume structure. Because of the low acceleration voltage, the stronger electron-atom scattering leads to a stronger contrast in the resulting image than standard TEM, especially for light elements. Furthermore, the low-kV STEM yields less radiation damage to the specimen, hence the structure can be preserved. In this work, two-dimensional STEM images of a 1-μm-thick cell section with projection angles between ±50° were collected, and the 3D volume structure was reconstructed using the simultaneous iterative reconstructive technique algorithm with the TomoJ plugin for ImageJ, which are both public domain software. Furthermore, the cross-sectional structure was obtained with the Volume Viewer plugin in ImageJ. Although the tilting angle is constrained and limits the resulting structural resolution, slicing the reconstructed volume generated the depth profile of the thick specimen with sufficient resolution to examine cellular uptake of Au nanoparticles, and the final position of these nanoparticles inside the cell was imaged.

  18. Practical aspects of monochromators developed for transmission electron microscopy

    Science.gov (United States)

    Kimoto, Koji

    2014-01-01

    A few practical aspects of monochromators recently developed for transmission electron microscopy are briefly reviewed. The basic structures and properties of four monochromators, a single Wien filter monochromator, a double Wien filter monochromator, an omega-shaped electrostatic monochromator and an alpha-shaped magnetic monochromator, are outlined. The advantages and side effects of these monochromators in spectroscopy and imaging are pointed out. A few properties of the monochromators in imaging, such as spatial or angular chromaticity, are also discussed. PMID:25125333

  19. Transmission of High-Power Electron Beams Through Small Apertures

    CERN Document Server

    Tschalär, C; Balascuta, S.; Benson, S.V.; Bertozzi, W.; Boyce, J.R.; Cowan, R.; Douglas, D.; Evtushenko, P.; Fisher, P.; Ihloff, E.; Kalantarians, N.; Kelleher, A.; Legg, R.; Milner, R.G.; Neil, G.R.; Ou, L.; Schmookler, B.; Tennant, C.; Williams, G.P.; Zhang, S.

    2013-01-01

    Tests were performed to pass a 100 MeV, 430 kWatt c.w. electron beam from the energy-recovery linac at the Jefferson Laboratory's FEL facility through a set of small apertures in a 127 mm long aluminum block. Beam transmission losses of 3 p.p.m. through a 2 mm diameter aperture were maintained during a 7 hour continuous run.

  20. Sub-10 nm device fabrication in a transmission electron microscope.

    Science.gov (United States)

    Fischbein, Michael D; Drndić, Marija

    2007-05-01

    We show that a high-resolution transmission electron microscope can be used to fabricate metal nanostructures and devices on insulating membranes by nanosculpting metal films. Fabricated devices include nanogaps, nanodiscs, nanorings, nanochannels, and nanowires with tailored curvatures and multi-terminal nanogap devices with nanoislands or nanoholes between the terminals. The high resolution, geometrical flexibility, and yield make this fabrication method attractive for many applications including nanoelectronics and nanofluidics.

  1. Electron transmission through a periodically driven graphene magnetic barrier

    Energy Technology Data Exchange (ETDEWEB)

    Biswas, R., E-mail: rbiswas.pkc@gmail.com [Department of Physics, P. K. College, Contai, Purba Medinipur, West Bengal – 721401 (India); Maiti, S. [Ajodhya Hills G.S.A.T High School, Ajodhya, Purulia, West Bengal – 723152 (India); Mukhopadhyay, S. [Purulia Zilla School, Dulmi Nadiha, Purulia, West Bengal – 723102 (India); Sinha, C. [Department of Physics, P. K. College, Contai, Purba Medinipur, West Bengal – 721401 (India); Department of Theoretical Physics, Indian Association for the Cultivation of Science, Jadavpur – 700032 (India)

    2017-05-10

    Electronic transport through graphene magnetic barriers is studied theoretically in presence of an external time harmonic scalar potential in the framework of non-perturbative Landau–Floquet Formalism. The oscillating field mostly suppresses the transmission for rectangular magnetic barrier structure and exhibits the Fano resonance for multiphoton processes due to the presence of bound state inside the barrier. While, for a pair of delta function barriers of larger separation, the oscillating potential suppresses the usual Fabry–Perot oscillations in the transmission and a new type of asymmetric Fano resonance is noted for smaller separation, occurring due to extended states between the barriers. - Highlights: • Tunnelling of the Dirac Fermions through oscillating pure magnetic barriers is reported for the first time. • The high energy transmission through a graphene magnetic barrier is suppressed by the application of time periodic modulation. • Suppression of the Fabry Perot transmission is noted due to the application of an external time harmonic potential. • Two kinds of the Fano resonances are noted in transmission through a pair of modulated δ-function magnetic barriers.

  2. Scanning transmission electron microscopy: Albert Crewe's vision and beyond.

    Science.gov (United States)

    Krivanek, Ondrej L; Chisholm, Matthew F; Murfitt, Matthew F; Dellby, Niklas

    2012-12-01

    Some four decades were needed to catch up with the vision that Albert Crewe and his group had for the scanning transmission electron microscope (STEM) in the nineteen sixties and seventies: attaining 0.5Å resolution, and identifying single atoms spectroscopically. With these goals now attained, STEM developments are turning toward new directions, such as rapid atomic resolution imaging and exploring atomic bonding and electronic properties of samples at atomic resolution. The accomplishments and the future challenges are reviewed and illustrated with practical examples.

  3. eV-TEM: Transmission electron microscopy in a low energy cathode lens instrument

    Energy Technology Data Exchange (ETDEWEB)

    Geelen, Daniël, E-mail: geelen@physics.leidenuniv.nl [Huygens-Kamerlingh Onnes Laboratory, Leiden Institute of Physics, Leiden University, P.O. Box 9504, 2300 RA Leiden (Netherlands); Thete, Aniket [Huygens-Kamerlingh Onnes Laboratory, Leiden Institute of Physics, Leiden University, P.O. Box 9504, 2300 RA Leiden (Netherlands); Schaff, Oliver; Kaiser, Alexander [SPECS GmbH, Voltastrasse 5, D-13355 Berlin (Germany); Molen, Sense Jan van der [Huygens-Kamerlingh Onnes Laboratory, Leiden Institute of Physics, Leiden University, P.O. Box 9504, 2300 RA Leiden (Netherlands); Tromp, Rudolf [IBM T.J. Watson Research Center, 1101 Kitchawan Road, P.O. Box 218, Yorktown Heights, NY 10598 (United States)

    2015-12-15

    We are developing a transmission electron microscope that operates at extremely low electron energies, 0–40 eV. We call this technique eV-TEM. Its feasibility is based on the fact that at very low electron energies the number of energy loss pathways decreases. Hence, the electron inelastic mean free path increases dramatically. eV-TEM will enable us to study elastic and inelastic interactions of electrons with thin samples. With the recent development of aberration correction in cathode lens instruments, a spatial resolution of a few nm appears within range, even for these very low electron energies. Such resolution will be highly relevant to study biological samples such as proteins and cell membranes. The low electron energies minimize adverse effects due to radiation damage. - Highlights: • We present a new way of performing low energy transmission electron microscopy in an aberration corrected LEEM/PEEM instrument. • We show a proof of principle where we measure transmitted electrons through a suspended graphene monolayer with a preliminary setup. • We present an improved setup design that provides better control of the incident electron beam.

  4. Pulsed Power for a Dynamic Transmission Electron Microscope

    Energy Technology Data Exchange (ETDEWEB)

    dehope, w j; browning, n; campbell, g; cook, e; king, w; lagrange, t; reed, b; stuart, b; Shuttlesworth, R; Pyke, B

    2009-06-25

    Lawrence Livermore National Laboratory (LLNL) has converted a commercial 200kV transmission electron microscope (TEM) into an ultrafast, nanoscale diagnostic tool for material science studies. The resulting Dynamic Transmission Electron Microscope (DTEM) has provided a unique tool for the study of material phase transitions, reaction front analyses, and other studies in the fields of chemistry, materials science, and biology. The TEM's thermionic electron emission source was replaced with a fast photocathode and a laser beam path was provided for ultraviolet surface illumination. The resulting photoelectron beam gives downstream images of 2 and 20 ns exposure times at 100 and 10 nm spatial resolution. A separate laser, used as a pump pulse, is used to heat, ignite, or shock samples while the photocathode electron pulses, carefully time-synchronized with the pump, function as probe in fast transient studies. The device functions in both imaging and diffraction modes. A laser upgrade is underway to make arbitrary cathode pulse trains of variable pulse width of 10-1000 ns. Along with a fast e-beam deflection scheme, a 'movie mode' capability will be added to this unique diagnostic tool. This talk will review conventional electron microscopy and its limitations, discuss the development and capabilities of DTEM, in particularly addressing the prime and pulsed power considerations in the design and fabrication of the DTEM, and conclude with the presentation of a deflector and solid-state pulser design for Movie-Mode DTEM.

  5. Transmission electron microscopy of the preclinical phase of experimental phytophotodermatitis

    Directory of Open Access Journals (Sweden)

    Hiram Larangeira de Almeida Jr

    2008-01-01

    Full Text Available OBJECTIVE: To examine the epidermis in induced phytophotodermatitis using transmission electron microscopy in order to detect histologic changes even before lesions are visible by light microscopy. INTRODUCTION: In the first six hours after the experimental induction of phytophotodermatitis, no changes are detectable by light microscopy. Only after 24 hours can keratinocyte necrosis and epidermal vacuolization be detected histologically, and blisters form by 48 hours. METHODS: The dorsum of four adult rats (Rattus norvegicus was manually epilated. After painting the right half of the rat with the peel juice of Tahiti lemon, they were exposed to sunlight for eight minutes under general anesthesia. The left side was used as the control and exposed to sunlight only. Biopsies were performed immediately after photoinduction and one and two hours later, and the tissue was analyzed by transmission electron microscopy. RESULTS: No histological changes were seen on the control side. Immediately after induction, vacuolization in keratinocytes was observed. After one hour, desmosomal changes were also observed in addition to vacuolization. Keratin filaments were not attached to the desmosomal plaque. Free desmosomes and membrane ruptures were also seen. At two hours after induction, similar changes were found, and granular degeneration of keratin was also observed. DISCUSSION: The interaction of sunlight and psoralens generates a photoproduct that damages keratinocyte proteins, leading to keratinocyte necrosis and blister formation. CONCLUSIONS: Transmission electron microscopy can detect vacuolization, lesions of the membrane, and desmosomes in the first two hours after experimental induction of phytophotodermatitis.

  6. Precision electron flow measurements in a disk transmission line.

    Energy Technology Data Exchange (ETDEWEB)

    Clark, Waylon T.; Pelock, Michael D.; Martin, Jeremy Paul; Jackson, Daniel Peter Jr.; Savage, Mark Edward; Stoltzfus, Brian Scott; Mendel, Clifford Will, Jr.; Pointon, Timothy David

    2008-01-01

    An analytic model for electron flow in a system driving a fixed inductive load is described and evaluated with particle in cell simulations. The simple model allows determining the impedance profile for a magnetically insulated transmission line given the minimum gap desired, and the lumped inductance inside the transition to the minimum gap. The model allows specifying the relative electron flow along the power flow direction, including cases where the fractional electron flow decreases in the power flow direction. The electrons are able to return to the cathode because they gain energy from the temporally rising magnetic field. The simulations were done with small cell size to reduce numerical heating. An experiment to compare electron flow to the simulations was done. The measured electron flow is {approx}33% of the value from the simulations. The discrepancy is assumed to be due to a reversed electric field at the cathode because of the inductive load and falling electron drift velocity in the power flow direction. The simulations constrain the cathode electric field to zero, which gives the highest possible electron flow.

  7. Transmission electron microscopy physics of image formation and microanalysis

    CERN Document Server

    Reimer, Ludwig

    1984-01-01

    The aim of this book is to outline the physics of image formation, electron­ specimen interactions and image interpretation in transmission electron mic­ roscopy. The book evolved from lectures delivered at the University of Munster and is a revised version of the first part of my earlier book Elek­ tronenmikroskopische Untersuchungs- und Priiparationsmethoden, omitting the part which describes specimen-preparation methods. In the introductory chapter, the different types of electron microscope are compared, the various electron-specimen interactions and their applications are summarized and the most important aspects of high-resolution, analytical and high-voltage electron microscopy are discussed. The optics of electron lenses is discussed in Chapter 2 in order to bring out electron-lens properties that are important for an understanding of the function of an electron microscope. In Chapter 3, the wave optics of elec­ trons and the phase shifts by electrostatic and magnetic fields are introduced; Fresne...

  8. Photocathode Optimization for a Dynamic Transmission Electron Microscope: Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Ellis, P; Flom, Z; Heinselman, K; Nguyen, T; Tung, S; Haskell, R; Reed, B W; LaGrange, T

    2011-08-04

    The Dynamic Transmission Electron Microscope (DTEM) team at Harvey Mudd College has been sponsored by LLNL to design and build a test setup for optimizing the performance of the DTEM's electron source. Unlike a traditional TEM, the DTEM achieves much faster exposure times by using photoemission from a photocathode to produce electrons for imaging. The DTEM team's work is motivated by the need to improve the coherence and current density of the electron cloud produced by the electron gun in order to increase the image resolution and contrast achievable by DTEM. The photoemission test setup is nearly complete and the team will soon complete baseline tests of electron gun performance. The photoemission laser and high voltage power supply have been repaired; the optics path for relaying the laser to the photocathode has been finalized, assembled, and aligned; the internal setup of the vacuum chamber has been finalized and mostly implemented; and system control, synchronization, and data acquisition has been implemented in LabVIEW. Immediate future work includes determining a consistent alignment procedure to place the laser waist on the photocathode, and taking baseline performance measurements of the tantalum photocathode. Future research will examine the performance of the electron gun as a function of the photoemission laser profile, the photocathode material, and the geometry and voltages of the accelerating and focusing components in the electron gun. This report presents the team's progress and outlines the work that remains.

  9. Precession electron diffraction and its utility for structural fingerprinting in the transmission electron microscope

    Science.gov (United States)

    Moeck, Peter; Rouvimov, Sergei; Nicolopoulos, Stavros

    2009-09-01

    Precession electron diffraction (PED) in a transmission electron microscope (TEM) is discussed in order to illustrate its utility for structural fingerprinting of nanocrystals. While individual nanocrystals may be fingerprinted structurally from PED spot patterns, ensembles of nanocrystals may be fingerprinted from powder PED ring patterns.

  10. The importance of transmission electron microscopy analysis of spermatozoa: Diagnostic applications and basic research.

    Science.gov (United States)

    Moretti, Elena; Sutera, Gaetano; Collodel, Giulia

    2016-06-01

    This review is aimed at discussing the role of ultrastructural studies on human spermatozoa and evaluating transmission electron microscopy as a diagnostic tool that can complete andrology protocols. It is clear that morphological sperm defects may explain decreased fertilizing potential and acquire particular value in the field of male infertility. Electron microscopy is the best method to identify systematic or monomorphic and non-systematic or polymorphic sperm defects. The systematic defects are characterized by a particular anomaly that affects the vast majority of spermatozoa in a semen sample, whereas a heterogeneous combination of head and tail defects found in variable percentages are typically non-systematic or polymorphic sperm defects. A correct diagnosis of these specific sperm alterations is important for choosing the male infertility's therapy and for deciding to turn to assisted reproduction techniques. Transmission electron microscopy (TEM) also represents a valuable method to explore the in vitro effects of different compounds (for example drugs with potential spermicidal activity) on the morphology of human spermatozoa. Finally, TEM used in combination with immunohistochemical techniques, integrates structural and functional aspects that provide a wide horizon in the understanding of sperm physiology and pathology. transmission electron microscopy: TEM; World Health Organization: WHO; light microscopy: LM; motile sperm organelle morphology examination: MSOME; intracytoplasmic morphologically selected sperm injection: IMSI; intracytoplasmic sperm injection: ICSI; dysplasia of fibrous sheath: DFS; primary ciliary dyskinesia: PCD; outer dense fibers: ODF; assisted reproduction technologies: ART; scanning electron microscopy: SEM; polyvinylpirrolidone: PVP; tert-butylhydroperoxide: TBHP.

  11. Vibrational and optical spectroscopies integrated with environmental transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Picher, Matthieu; Mazzucco, Stefano [Center for Nanoscale Science and Technology, National Institute of Standards and Technology, Gaithersburg, MD 20899-6203 (United States); Institute for Research in Electronics and Applied Physics, University of Maryland, College Park, MD 20740 (United States); Blankenship, Steve [Center for Nanoscale Science and Technology, National Institute of Standards and Technology, Gaithersburg, MD 20899-6203 (United States); Sharma, Renu, E-mail: renu.sharma@nist.gov [Center for Nanoscale Science and Technology, National Institute of Standards and Technology, Gaithersburg, MD 20899-6203 (United States)

    2015-03-15

    Here, we present a measurement platform for collecting multiple types of spectroscopy data during high-resolution environmental transmission electron microscopy observations of dynamic processes. Such coupled measurements are made possible by a broadband, high-efficiency, free-space optical system. The critical element of the system is a parabolic mirror, inserted using an independent hollow rod and placed below the sample holder which can focus a light on the sample and/or collect the optical response. We demonstrate the versatility of this optical setup by using it to combine in situ atomic-scale electron microscopy observations with Raman spectroscopy. The Raman data is also used to measure the local temperature of the observed sample area. Other applications include, but are not limited to: cathodo- and photoluminescence spectroscopy, and use of the laser as a local, high-rate heating source. - Highlights: • Broadband, high-efficiency design adaptable to other electron microscopes. • Raman spectroscopy integrated with environmental transmission electron microscopy. • Raman spectra peak frequency shifts enable measurement of local sample temperature. • Multiple types of optical spectroscopy enabled, e.g. cathodoluminescence.

  12. Development of advanced electron holographic techniques and application to industrial materials and devices.

    Science.gov (United States)

    Yamamoto, Kazuo; Hirayama, Tsukasa; Tanji, Takayoshi

    2013-06-01

    The development of a transmission electron microscope equipped with a field emission gun paved the way for electron holography to be put to practical use in various fields. In this paper, we review three advanced electron holography techniques: on-line real-time electron holography, three-dimensional (3D) tomographic holography and phase-shifting electron holography, which are becoming important techniques for materials science and device engineering. We also describe some applications of electron holography to the analysis of industrial materials and devices: GaAs compound semiconductors, solid oxide fuel cells and all-solid-state lithium ion batteries.

  13. EMERGENCE OF A LYOTROPIC LAMELLAR PHASE - SURFACTANT-AQUEOUS PHASE CONTACT EXPERIMENTS EXAMINED WITH A CRYO-TRANSMISSION ELECTRON-MICROSCOPE : Surfactant-Aqueous Phase Contact Experiments Examined with a Cryo-Transmission Electron Microscope

    NARCIS (Netherlands)

    Sein, A; van Breemen, J.F.L.; Engberts, J.B.F.N.

    A phase penetration experiment has been conducted, employing a cryo-transmission electron microscope (cryo-TEM). With this technique, the phase transitions and the molecular rearrangement that result from the phase penetration can be studied on almost the molecular level. The technique has been

  14. Transmission electron microscope characterisation of molar-incisor-hypomineralisation.

    Science.gov (United States)

    Xie, Zonghan; Kilpatrick, Nicky M; Swain, Michael V; Munroe, Paul R; Hoffman, Mark

    2008-10-01

    Molar-incisor-hypomineralisation (MIH), one of the major developmental defects in dental enamel, is presenting challenge to clinicians due, in part, to the limited understanding of microstructural changes in affected teeth. Difficulties in the preparation of site-specific transmission electron microscope (TEM) specimens are partly responsible for this deficit. In this study, a dual-beam field emission scanning electron microscope (FESEM)/focused ion beam (FIB) milling instrument was used to prepare electron transparent specimens of sound and hypomineralised enamel. Microstructural analysis revealed that the hypomineralised areas in enamel were associated with marked changes in microstructure; loosely packed apatite crystals within prisms and wider sheath regions were identified. Microstructural changes appear to occur during enamel maturation and may be responsible for the dramatic reduction in mechanical properties of the affected regions. An enhanced knowledge of the degradation of structural integrity in hypomineralised enamel could shed light on more appropriate management strategies for these developmental defects.

  15. Scanning transmission electron microscopy imaging dynamics at low accelerating voltages

    Energy Technology Data Exchange (ETDEWEB)

    Lugg, N.R. [School of Physics, University of Melbourne, Parkville, Victoria 3010 (Australia); Findlay, S.D. [Institute of Engineering Innovation, The University of Tokyo, Tokyo 116-0013 (Japan); Shibata, N. [Institute of Engineering Innovation, The University of Tokyo, Tokyo 116-0013 (Japan); PRESTO, Japan Science and Technology Agency, Saitama 332-0012 (Japan); Mizoguchi, T. [Institute of Industrial Science, The University of Tokyo, Tokyo 153-8505 (Japan); D' Alfonso, A.J. [School of Physics, University of Melbourne, Parkville, Victoria 3010 (Australia); Allen, L.J., E-mail: lja@unimelb.edu.au [School of Physics, University of Melbourne, Parkville, Victoria 3010 (Australia); Ikuhara, Y. [Institute of Engineering Innovation, The University of Tokyo, Tokyo 116-0013 (Japan); Nanostructures Research Laboratory, Japan Fine Ceramic Center, Nagoya 456-8587 (Japan); WPI Advanced Institute for Materials Research, Tohoku University, Sendai 980-8577 (Japan)

    2011-07-15

    Motivated by the desire to minimize specimen damage in beam sensitive specimens, there has been a recent push toward using relatively low accelerating voltages (<100kV) in scanning transmission electron microscopy. To complement experimental efforts on this front, this paper seeks to explore the variations with accelerating voltage of the imaging dynamics, both of the channelling of the fast electron and of the inelastic interactions. High-angle annular-dark field, electron energy loss spectroscopic imaging and annular bright field imaging are all considered. -- Highlights: {yields} Both elastic and inelastic scattering in STEM are acceleration voltage dependent. {yields} HAADF, EELS and ABF imaging are assessed with a view to optimum imaging. {yields} Lower accelerating voltages improve STEM EELS contrast in very thin crystals. {yields} Higher accelerating voltages give better STEM EELS contrast in thicker crystals. {yields} At fixed resolution, higher accelerating voltage aids ABF imaging of light elements.

  16. A Transmission Electron Microscope Investigation of Space Weathering Effects in Hayabusa Samples

    Science.gov (United States)

    Keller, Lindsay P.; Berger, Eve L.

    2014-01-01

    The Hayabusa mission to asteroid 25143 Itokawa successfully returned the first direct samples of the regolith from the surface of an asteroid. The Hayabusa samples thus present a special opportunity to directly investigate the evolution of asteroidal surfaces, from the development of the regolith to the study of the more complex effects of space weathering. Here we describe the mineralogy, microstructure and composition of three Hayabusa mission particles using transmission electron microscope (TEM) techniques

  17. Characterization nanoparticles-based vaccines and vaccine candidates: a Transmission Electron Microscopy study

    Directory of Open Access Journals (Sweden)

    I. Menéndez I

    2016-05-01

    Full Text Available Transmission Electron Microscopy (TEM is a valuable tool for the biotech industry. This paper summarizes some of the contributions of MET in the characterization of the recombinant antigens are part of vaccines or vaccine candidates obtained in the CIGB. It mentions the use of complementary techniques MET (Negative staining, and immunoelectron that enhance visualization and ultrastructural characterization of the recombinant proteins obtained by Genetic Engineering.

  18. Dislocation dynamics in Al-Mg-Zn alloys : A nuclear magnetic resonance and transmission electron microscopic study

    NARCIS (Netherlands)

    Hosson, J.Th.M. De; Kanert, O.; Schlagowski, U.; Boom, G.

    1988-01-01

    Pulsed nuclear magnetic resonance (NMR) proved to be a complementary new technique for the study of moving dislocations in Al-Mg-Zn alloys. The NMR technique, in combination with transmission electron microscopy (TEM), has been applied to study dislocation motion in Al-0.6 at. % Mg-1 at. % Zn and

  19. Three-Dimensional scanning transmission electron microscopy of biological specimens

    KAUST Repository

    De Jonge, Niels

    2010-01-18

    A three-dimensional (3D) reconstruction of the cytoskeleton and a clathrin-coated pit in mammalian cells has been achieved from a focal-series of images recorded in an aberration-corrected scanning transmission electron microscope (STEM). The specimen was a metallic replica of the biological structure comprising Pt nanoparticles 2-3 nm in diameter, with a high stability under electron beam radiation. The 3D dataset was processed by an automated deconvolution procedure. The lateral resolution was 1.1 nm, set by pixel size. Particles differing by only 10 nm in vertical position were identified as separate objects with greater than 20% dip in contrast between them. We refer to this value as the axial resolution of the deconvolution or reconstruction, the ability to recognize two objects, which were unresolved in the original dataset. The resolution of the reconstruction is comparable to that achieved by tilt-series transmission electron microscopy. However, the focal-series method does not require mechanical tilting and is therefore much faster. 3D STEM images were also recorded of the Golgi ribbon in conventional thin sections containing 3T3 cells with a comparable axial resolution in the deconvolved dataset. © 2010 Microscopy Society of America.

  20. Structural Fingerprinting of Nanocrystals in the Transmission Electron Microscope

    Science.gov (United States)

    Rouvimov, Sergei; Plachinda, Pavel; Moeck, Peter

    2010-03-01

    Three novel strategies for the structurally identification of nanocrystals in a transmission electron microscope are presented. Either a single high-resolution transmission electron microscopy image [1] or a single precession electron diffractogram (PED) [2] may be employed. PEDs from fine-grained crystal powders may also be utilized. Automation of the former two strategies is in progress and shall lead to statistically significant results on ensembles of nanocrystals. Open-access databases such as the Crystallography Open Database which provides more than 81,500 crystal structure data sets [3] or its mainly inorganic and educational subsets [4] may be utilized. [1] http://www.scientificjournals.org/journals 2007/j/of/dissertation.htm [2] P. Moeck and S. Rouvimov, in: {Drugs and the Pharmaceutical Sciences}, Vol. 191, 2009, 270-313 [3] http://cod.ibt.lt, http://www.crystallography.net, http://cod.ensicaen.fr, http://nanocrystallography.org, http://nanocrystallography.net, http://journals.iucr.org/j/issues/2009/04/00/kk5039/kk5039.pdf [4] http://nanocrystallography.research.pdx.edu/CIF-searchable

  1. Improving transmission rates of electronic discharge summaries to GPs.

    Science.gov (United States)

    Barr, Rory; Chin, Kuen Yeow; Yeong, Keefai

    2013-01-01

    Discharge summaries are a vital tool to communicate information from Hospital to Primary Care teams; updating GPs about what happened during an admission, and handing over care detailing any follow up care required. Historically, Discharge Summaries have been posted to hospitals, increasing costs for hospitals, creating administrative work for GP practices receiving the letters, and resulting in some letters being lost or delayed in reaching the GP, with implications for patient safety if follow up requests are not received and acted upon. In an effort to improve patient care, the Clinical Commissioning Group in Surrey drew up a contract with Ashford and St Peter's Foundation Trust, aiming to increase the percentage of discharge summaries sent electronically from the rate of 9% sent within 24 hours, to over 75%. This contract set targets of 50% in May, 65% in June, and 80% in July. Financial penalties would be imposed if targets were not achieved, starting in June 2013. The Trust set up a working group comprising of doctors, IT personnel and ward PAs to devise a multi-pronged solution to achieve this target. The electronic discharge summary system was reviewed and improvements were designed and developed to make the process of signing off letters easier, and transmission of signed off letters became automated rather than requiring manual transmission by ward PAs. Presentations and leaflets to explain the importance of prompt completion and transmission of discharge summaries were given to Doctors to improve compliance using the revised IT system. Figures on transmission rates were automatically emailed to key stakeholders every day (Ward PAs, Divisional Leads) showing performance on each ward. This helped identify areas requiring more intervention. Areas (e.g. Day Surgery) that had not used electronic discharge summaries were engaged with, and persuaded to take part. As a result, transmission rates of Discharge Summaries within 24 hours of patient discharge

  2. Metallocarbohedrenes: Transmission Electron Microscopy of Mass Gated Deposits

    Science.gov (United States)

    Castleman, M. E. Lyn, Jr.

    2002-03-01

    Titanium and zirconium Met-Car cluster ions have been detected from the direct laser vaporization of metal-graphite mixtures using time-of-flight mass spectrometry. Optimization of the production conditions enabled sufficient intensities to mass select and deposit Met-Cars on surfaces. High-resolution transmission electron microscopy images of mass gated Met-Car species reveals deposited nanocrystals 2 nm in diameter. Diffraction patterns indicate the presence of multiple species and shows that the deposits have spatial orientation. Lattice parameters have been extracted. The implication of the findings will be discussed. Support for the work has been from the AFOSR F49620-01-1-0122.

  3. Simulation of scanning transmission electron microscope images on desktop computers

    Energy Technology Data Exchange (ETDEWEB)

    Dwyer, C., E-mail: christian.dwyer@mcem.monash.edu.au [Monash Centre for Electron Microscopy, Department of Materials Engineering, Monash University, Victoria 3800 (Australia)

    2010-02-15

    Two independent strategies are presented for reducing the computation time of multislice simulations of scanning transmission electron microscope (STEM) images: (1) optimal probe sampling, and (2) the use of desktop graphics processing units. The first strategy is applicable to STEM images generated by elastic and/or inelastic scattering, and requires minimal effort for its implementation. Used together, these two strategies can reduce typical computation times from days to hours, allowing practical simulation of STEM images of general atomic structures on a desktop computer.

  4. Quantifying the growth of individual graphene layers by in situ environmental transmission electron microscopy

    DEFF Research Database (Denmark)

    Kling, Jens; Hansen, Thomas Willum; Wagner, Jakob Birkedal

    2016-01-01

    The growth dynamics of layered carbon is studied by means of in situ transmission electron microscopy in order to obtain a deeper insight into the growth by chemical vapor deposition, which at present is the technique of choice for growing layered carbon. In situ growth of layered carbon structures...... on nickel using acetylene as carbon precursor gas is studied in the electron microscope at various gas pressures. By following the growth of individual graphene layers on the Ni surface, local growth rates are determined as a function of precursor pressure. Two growth regimes are identified, an initial...

  5. Advances in imaging and electron physics the scanning transmission electron microscope

    CERN Document Server

    Hawkes, Peter W

    2009-01-01

    Advances in Imaging and Electron Physics merges two long-running serials--Advances in Electronics and Electron Physics and Advances in Optical and Electron Microscopy. This series features extended articles on the physics of electron devices (especially semiconductor devices), particle optics at high and low energies, microlithography, image science and digital image processing, electromagnetic wave propagation, electron microscopy, and the computing methods used in all these domains.  This particular volume presents several timely articles on the scanning transmission electron microscope. Updated with contributions from leading international scholars and industry experts Discusses hot topic areas and presents current and future research trends Provides an invaluable reference and guide for physicists, engineers and mathematicians.

  6. Measurement of Specimen Thickness by Using Electron Holography and Electron Dynamic Calculation with a Transmission Electron Microscope

    Institute of Scientific and Technical Information of China (English)

    王岩国; 刘红荣; 杨奇斌; 张泽

    2003-01-01

    A method of transmission-electron microscopy for accurate measurement of specimen thickness has been proposed based on off-axis electron holography along with the dynamic electron diffraction simulation. The phase shift of the exit object wave with respect to the reference wave in vacuum, resulting from the scattering within the specimen, has been simulated versus the specimen thickness by the dynamic electron diffraction formula. Offaxis electron holography in a field emission gun transmission-electron microscope has been used to determine the phase shift of the exit wave. The specimen thickness can be obtained by match of the experimental and simulated phase shift. Based on the measured phase shift of the [110] oriented copper foil, the thickness can be determined at a good level of accuracy with an error less than ~10%.

  7. Advanced Transmission Electron Microscopy Applications in Nano-Materials and Nano-Technology Developments

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    @@ Nano-technology development is nowadays a very hot topics in many research fields. Nano-materials are the foundations for developing this new technology. In order to fully understand the basic material science problems behind this topics, transmission electron microscopy (TEM) becomes the must and one of the most important technique to analyze the nano-size structure and composition using the most advanced high resolution TEM technique with nano-beam EDS and energy filter EELS to study the fine structures, crystallography, chemical composition, and optical properties of many different nano-materials in different industries applications.

  8. Advanced Transmission Electron Microscopy Applications in Nano-Materials and Nano-Technology Developments

    Institute of Scientific and Technical Information of China (English)

    KAI; J.J.

    2001-01-01

    Nano-technology development is nowadays a very hot topics in many research fields. Nano-materials are the foundations for developing this new technology. In order to fully understand the basic material science problems behind this topics, transmission electron microscopy (TEM) becomes the must and one of the most important technique to analyze the nano-size structure and composition using the most advanced high resolution TEM technique with nano-beam EDS and energy filter EELS to study the fine structures, crystallography, chemical composition, and optical properties of many different nano-materials in different industries applications.  ……

  9. Atomic-Scale Study Of Complex Cobalt Oxide Using Scanning Transmission Electron Microscope

    Science.gov (United States)

    Gulec, Ahmet

    Cobalt oxides offer a rich ?eld for the formation of novel phases, including superconductors and exotic magnetic phases, involving a mixed valence state for cobalt and/or the presence of oxygen vacancies. Having spin states, such as, low spin (LS), high spin (HS), and intermediate spin (IS), cobalt oxides differ from other 3d metal oxides The presence of such spin states make the physics of the cobalt oxides so complicated that it has not yet been completely understood. In order to improve our understanding of the various phase transitions observed in Cobalt oxides and to comprehend the relationship between crystal and electronic structure, both high energy resolution and high spatial resolution are essential. Fortunately, transmission electron microscopy (TEM) is a technique which is capable of ful?lling both of these requirements. In this thesis, I have utilized unique techniques in a scanning transmission electron microscope (STEM) to analyze the atomic-scale structure-property relationship, both at room temperature and through insitu cooling to liquid nitrogen (LN2) temperature. In particular, by using correlated Z-contrast imaging, electron energy loss spectrum (EELS) and electron energy loss magnetic circular dichroism (EMCD), the structure, composition, bonding and magnetic behavior are characterized directly on the atomic scale.

  10. Transmission electron microscopy of bulk specimens over 10µm in thickness.

    Science.gov (United States)

    Sadamatsu, Sunao; Tanaka, Masaki; Higashida, Kenji; Matsumura, Syo

    2016-03-01

    We succeeded the observation of microstructures in bulk-sized specimens of over 10µm in thickness by employing a technique that combines transmission electron microscopy (TEM) with energy-filtered imaging based on electron energy-loss spectroscopy (EELS). This method is unique in that it incorporates the inelastically scattered electrons into the imaging process. Using this technique, bright and sharp images of dislocations in crystalline silicon specimens as thick as 10µm were obtained. A calibration curve to determine foil thickness of such a thick specimen was also derived. This method simply extends the observable thickness range in TEM. If combined with tilt series of observation over a significant range of angle, it will disclose three dimensional nanostructures in a µm-order block of a specimen, promoting our understanding of the controlling mechanisms behind various bulky material properties. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  11. Reconstruction and visualization of nanoparticle composites by transmission electron tomography

    Energy Technology Data Exchange (ETDEWEB)

    Wang, X.Y. [National Institute for Nanotechnology, 11421 Saskatchewan Drive, Edmonton, Canada T6H 2M9 (Canada); Department of Physics, University of Alberta, Edmonton, Canada T6G 2G7 (Canada); Lockwood, R. [National Institute for Nanotechnology, 11421 Saskatchewan Drive, Edmonton, Canada T6H 2M9 (Canada); Malac, M., E-mail: marek.malac@nrc-cnrc.gc.ca [National Institute for Nanotechnology, 11421 Saskatchewan Drive, Edmonton, Canada T6H 2M9 (Canada); Department of Physics, University of Alberta, Edmonton, Canada T6G 2G7 (Canada); Furukawa, H. [SYSTEM IN FRONTIER INC., 2-8-3, Shinsuzuharu bldg. 4F, Akebono-cho, Tachikawa-shi, Tokyo 190-0012 (Japan); Li, P.; Meldrum, A. [National Institute for Nanotechnology, 11421 Saskatchewan Drive, Edmonton, Canada T6H 2M9 (Canada)

    2012-02-15

    This paper examines the limits of transmission electron tomography reconstruction methods for a nanocomposite object composed of many closely packed nanoparticles. Two commonly used reconstruction methods in TEM tomography were examined and compared, and the sources of various artefacts were explored. Common visualization methods were investigated, and the resulting 'interpretation artefacts' ( i.e., deviations from 'actual' particle sizes and shapes arising from the visualization) were determined. Setting a known or estimated nanoparticle volume fraction as a criterion for thresholding does not in fact give a good visualization. Unexpected effects associated with common built-in image filtering methods were also found. Ultimately, this work set out to establish the common problems and pitfalls associated with electron beam tomographic reconstruction and visualization of samples consisting of closely spaced nanoparticles. -- Highlights: Black-Right-Pointing-Pointer Electron tomography limits were explored by both experiment and simulation. Black-Right-Pointing-Pointer Reliable quantitative volumetry using electron tomography is not presently feasible. Black-Right-Pointing-Pointer Volume rendering appears to be better choice for visualization of composite samples.

  12. Transmission zero in a quantum dot with strong electron-electron interaction: Perturbative conductance calculations

    Science.gov (United States)

    Kim, Sejoong; Lee, Hyun-Woo

    2006-05-01

    A pioneering experiment [E. Schuster, E. Buks, M. Heiblum, D. Mahalu, V. Umansky, and Hadas Shtrikman, Nature 385, 417 (1997)] reported the measurement of the transmission phase of an electron traversing a quantum dot and found the intriguing feature of a sudden phase drop in the conductance valleys. Based on the Friedel sum rule for a spinless effective one-dimensional system, it has been previously argued [H.-W. Lee, Phys. Rev. Lett. 82, 2358 (1999)] that the sudden phase drop should be accompanied by the vanishing of the transmission amplitude, or transmission zero. Here we address roles of strong electron-electron interactions on the electron transport through a two-level quantum dot where one level couples with the leads much more strongly than the other level does [P. G. Silvestrov and Y. Imry, Phys. Rev. Lett. 85, 2565 (2000)]. We perform a perturbative conductance calculation with an explicit account of large charging energy and verify that the resulting conductance exhibits transmission zero, in agreement with the analysis based on the Friedel sum rule.

  13. Transmission line resonance technique for eccentric core optical fibers

    Science.gov (United States)

    Georgantzos, E.; Boucouvalas, A. C.

    2016-12-01

    In several cases optical fibers in telecommunications have cores of non circular geometry. Fibre optic deformations appear in optical fibres for many reasons. Optical fibre core ellipticity for example where the fibre optic core is not perfectly circular due to fibre optic manufacturing tolerances, is measured and often is a problem. Optical fibre core eccentricity, where the fibre core is not on the axis of the fibre, but it is offset by a small length. This is another issue and very important for ensuring performance low loss splices and connector losses. Both of ellipticity and eccentricity are specified in accordance to international standards for fibre optic manufacturing telecommunications grade fibres. The present paper studies ellipticity and core eccentricity specifically and presents a new method for analysing their effect. We present an extension of the transmission line technique as a means of studying such fibers and deriving necessary parameters. Conformal mapping on the other hand is a simple mathematical tool by which we can generate sets of orthogonal two-dimensional coordinate systems. Shortly a conformal map of Cartesian two-dimensional space is defined by any analytical function W(z) where z, w, are: z = x + jy, W = θ + j φ The function deriving by the conformal mapping transformation h(θ ,φ )=| ∂w/∂z | = 1/|∂z/∂w|, can be used in order to define ∇A → and ∇×A → where A → is the magnetic or electric field in the derived orthogonal coordinate system. Useful conformal maps for fiber optics applications should have the property that the equation θ(x, y) = constant, is forming closed curves in a Cartesian two-dimensional space (x,y). If θ(x, y) = constant represents a set of co-eccentric circles, we obtain the normal case of conventional fibers with circular cores. If θ(x, y) = constant represents a set of eclipses, we are have the formation of elliptic core optical fibers. If θ(x, y) = constant represents a set of

  14. A Q-Modulation Technique for Efficient Inductive Power Transmission.

    Science.gov (United States)

    Kiani, Mehdi; Lee, Byunghun; Yeon, Pyungwoo; Ghovanloo, Maysam

    2015-12-01

    A fully-integrated power management ASIC for efficient inductive power transmission has been presented capable of automatic load transformation using a method, called Q-modulation. Q-modulation is an adaptive scheme that offers load matching against a wide range of loading (RL ) and coupling distance (d23 ) variations in inductive links to maintain high power transfer efficiency (PTE). It is suitable for inductive powering implantable microelectronic devices (IMDs), recharging mobile electronics, and electric vehicles. In Q-modulation, the zero-crossings of the induced current in the receiver (Rx) LC-tank are detected and a low-loss switch chops the Rx LC-tank for part of the power carrier cycle to form a high-Q LC-tank and store the maximum energy, which is then transferred to RL by opening the switch. By adjusting the duty cycle (D), the loaded-Q of the Rx LC-tank can be dynamically modulated to compensate for variations in RL . A Q-modulation power management (QMPM) prototype chip was fabricated in a 0.35-μm standard CMOS process, occupying 4.8 mm(2). In a 1.45 W wireless power transfer setup, using a class-E power amplifier (PA) operating at 2 MHz, the QMPM successfully increased the inductive link PTE and the overall power efficiency by 98.5% and 120.7% at d23 = 8 cm, respectively, by compensating for 150 Ω variation in RL at D = 45%.

  15. Nuclear Electronics: Superconducting Detectors and Processing Techniques

    Science.gov (United States)

    Polushkin, Vladimir

    2004-06-01

    With the commercialisation of superconducting particles and radiation detectors set to occur in the very near future, nuclear analytical instrumentation is taking a big step forward. These new detectors have a high degree of accuracy, stability and speed and are suitable for high-density multiplex integration in nuclear research laboratories and astrophysics. Furthermore, superconducting detectors can also be successfully applied to food safety, airport security systems, medical examinations, doping tests & forensic investigations. This book is the first to address a new generation of analytical tools based on new superconductor detectors demonstrating outstanding performance unsurpassed by any other conventional devices. Presenting the latest research and development in nanometer technologies and biochemistry this book: * Discusses the development of nuclear sensing techniques. * Provides guidance on the design and use of the next generation of detectors. * Describes cryogenic detectors for nuclear measurements and spectrometry. * Covers primary detectors, front-end readout electronics and digital signal processing. * Presents applications in nanotechnology and modern biochemistry including DNA sequencing, proteinomics, microorganisms. * Features examples of two applications in X-ray electron probe nanoanalysis and time-of-flight mass spectrometry. This comprehensive treatment is the ideal reference for researchers, industrial engineers and graduate students involved in the development of high precision nuclear measurements, nuclear analytical instrumentation and advanced superconductor primary sensors. This book will also appeal to physicists, electrical and electronic engineers in the nuclear industry.

  16. The application of Graphene as a sample support in Transmission Electron Microscopy

    CERN Document Server

    Pantelic, R S; Kaiser, U; Stahlberg, H

    2012-01-01

    Transmission electron microscopy has witnessed rampant development and surging point resolution over the past few years. The improved imaging performance of modern electron microscopes shifts the bottleneck for image contrast and resolution to sample preparation. Hence, it is increasingly being realized that the full potential of electron microscopy will only be realized with the optimization of current sample preparation techniques. Perhaps the most recognized issues are background signal and noise contributed by sample supports, sample charging and instability. Graphene provides supports of single atom thickness, extreme physical stability, periodic structure, and ballistic electrical conductivity. As an increasing number of applications adapting graphene to their benefit emerge, we discuss the unique capabilities afforded by the use of graphene as a sample support for electron microscopy.

  17. Iterative reconstruction of magnetic induction using Lorentz transmission electron tomography

    Energy Technology Data Exchange (ETDEWEB)

    Phatak, C., E-mail: cd@anl.gov [Materials Science Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Gürsoy, D. [Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439 (United States)

    2015-03-15

    Intense ongoing research on complex nanomagnetic structures requires a fundamental understanding of the 3D magnetization and the stray fields around the nano-objects. 3D visualization of such fields offers the best way to achieve this. Lorentz transmission electron microscopy provides a suitable combination of high resolution and ability to quantitatively visualize the magnetization vectors using phase retrieval methods. In this paper, we present a formalism to represent the magnetic phase shift of electrons as a Radon transform of the magnetic induction of the sample. Using this formalism, we then present the application of common tomographic methods particularly the iterative methods, to reconstruct the 3D components of the vector field. We present an analysis of the effect of missing wedge and the limited angular sampling as well as reconstruction of complex 3D magnetization in a nanowire using simulations. - Highlights: • We present a formalism to represent electron-optical magnetic phase shift as a Radon transform of the 3D magnetic induction of the nano-object. • We have analyzed four different tomographic reconstruction methods for vectorial data reconstruction. • Reconstruction methods were tested for varying experimental limitations such as limited tilt range and limited angular sampling. • The analysis showed that Gridrec and SIRT methods performed better with lower errors than other reconstruction methods.

  18. Improved Zernike-type phase contrast for transmission electron microscopy.

    Science.gov (United States)

    Koeck, P J B

    2015-07-01

    Zernike phase contrast has been recognized as a means of recording high-resolution images with high contrast using a transmission electron microscope. This imaging mode can be used to image typical phase objects such as unstained biological molecules or cryosections of biological tissue. According to the original proposal discussed in Danev and Nagayama (2001) and references therein, the Zernike phase plate applies a phase shift of π/2 to all scattered electron beams outside a given scattering angle and an image is recorded at Gaussian focus or slight underfocus (below Scherzer defocus). Alternatively, a phase shift of -π/2 is applied to the central beam using the Boersch phase plate. The resulting image will have an almost perfect contrast transfer function (close to 1) from a given lowest spatial frequency up to a maximum resolution determined by the wave length, the amount of defocus and the spherical aberration of the microscope. In this paper, I present theory and simulations showing that this maximum spatial frequency can be increased considerably without loss of contrast by using a Zernike or Boersch phase plate that leads to a phase shift between scattered and unscattered electrons of only π /4, and recording images at Scherzer defocus. The maximum resolution can be improved even more by imaging at extended Scherzer defocus, though at the cost of contrast loss at lower spatial frequencies. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.

  19. A transmission electron microscopy study of presolar hibonite

    CERN Document Server

    Zega, Thomas J; Nittler, Larry R; Stroud, Rhonda M

    2011-01-01

    We report isotopic and microstructural data on five presolar hibonite grains identified in an acid residue of the Krymka LL3.1 ordinary chondrite. Isotopic measurements by secondary ion mass spectrometry (SIMS) verified a presolar circumstellar origin for the grains. Transmission electron microscopy (TEM) examination of the crystal structure and chemistry of the grains was enabled by in situ sectioning and lift-out with a focused-ion-beam scanning-electron microscope. Comparisons of isotopic compositions with models indicate that four of the five grains formed in low-mass stars that evolved through the red-giant/asymptotic-giant branches, whereas one grain formed in the ejecta of a Type II supernova. Selected-area electron-diffraction patterns show that all grains are single crystals of hibonite. Some grains contain stacking faults and small spreads in orientation that can be attributed to a combination of growth defects and mechanical processing by grain-grain collisions. The similar structure of the superno...

  20. Secondary Electron Emission Materials for Transmission Dynodes in Novel Photomultipliers: A Review

    Directory of Open Access Journals (Sweden)

    Shu Xia Tao

    2016-12-01

    Full Text Available Secondary electron emission materials are reviewed with the aim of providing guidelines for the future development of novel transmission dynodes. Materials with reflection secondary electron yield higher than three and transmission secondary electron yield higher than one are tabulated for easy reference. Generations of transmission dynodes are listed in the order of the invention time with a special focus on the most recent atomic-layer-deposition synthesized transmission dynodes. Based on the knowledge gained from the survey of secondary election emission materials with high secondary electron yield, an outlook of possible improvements upon the state-of-the-art transmission dynodes is provided.

  1. Transmission Probability for Interacting Electrons Connected to Reservoirs

    Science.gov (United States)

    Oguri, Akira

    2001-09-01

    Transport through small interacting systems connected to noninteracting leads is studied based on the Kubo formalism using a Éliashberg theory of the analytic properties of the vertex part. The transmission probability, by which the conductance is expressed as g = (2e2/h) \\int dɛ (- \\partial f / \\partial ɛ) \\mathcal{T}(ɛ), is introduced for interacting electrons. Here f(ɛ) is the Fermi function, and the transmission probability T(ɛ) is defined in terms of a current vertex or a three-point correlation function. We apply this formulation to a series of Anderson impurities of size N (=1, 2, 3, 4), and calculate T(ɛ) using the order U2 self-energy and current vertex which satisfy a generalized Ward identity. The results show that T(ɛ) has much information about the excitation spectrum: T(ɛ) has two broad peaks of the upper and lower Hubbard bands in addition to N resonant peaks which have direct correspondence with the noninteracting spectrum. The peak structures disappear at high temperatures.

  2. Transmission electron microscope sample holder with optical features

    Science.gov (United States)

    Milas, Mirko [Port Jefferson, NY; Zhu, Yimei [Stony Brook, NY; Rameau, Jonathan David [Coram, NY

    2012-03-27

    A sample holder for holding a sample to be observed for research purposes, particularly in a transmission electron microscope (TEM), generally includes an external alignment part for directing a light beam in a predetermined beam direction, a sample holder body in optical communication with the external alignment part and a sample support member disposed at a distal end of the sample holder body opposite the external alignment part for holding a sample to be analyzed. The sample holder body defines an internal conduit for the light beam and the sample support member includes a light beam positioner for directing the light beam between the sample holder body and the sample held by the sample support member.

  3. Kinematics of gold nanoparticles manipulation in situ transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Alducin, Diego; Casillas, Gilberto; Mendoza-Santoyo, Fernando; Ponce, Arturo; José-Yacamán, Miguel, E-mail: miguel.yacaman@utsa.edu [University of Texas at San Antonio, Department of Physics and Astronomy (United States)

    2015-05-15

    Nanostructured materials such as nanoparticles, nanotubes, and nanowires are subject to different forces regimes compared with their macroscopic counterparts. In this work, we report the experimental manipulation of an individual gold nanoparticle (96 nm) capped with PVP considering forces surrounding the nanoparticle such as adhesion, friction, and the external load in real time, and how the differences between these forces produce distinct motions. Combining a scanning probe tool within a transmission electron microscope, we manipulated a gold nanoparticle and recorded the sliding and rolling kinematic motions. Our observations show quantitatively the adhesion force, maximum rolling resistance, and friction coefficients of the probe and the surface of the capped particle as well as particle and substrate surface.

  4. Transmission electron microscope cells for use with liquid samples

    Energy Technology Data Exchange (ETDEWEB)

    Khalid, Waqas; Alivisatos, Paul A.; Zettl, Alexander K.

    2016-08-09

    This disclosure provides systems, methods, and devices related to transmission electron microscopy cells for use with liquids. In one aspect a device includes a substrate, a first graphene layer, and a second graphene layer. The substrate has a first surface and a second surface. The first surface defines a first channel, a second channel, and an outlet channel. The first channel and the second channel are joined to the outlet channel. The outlet channel defines a viewport region forming a though hole in the substrate. The first graphene layer overlays the first surface of the substrate, including an interior area of the first channel, the second channel, and the outlet channel. The second graphene layer overlays the first surface of the substrate, including open regions defined by the first channel, the second channel, and the outlet channel.

  5. [Multiple transmission electron microscopic image stitching based on sift features].

    Science.gov (United States)

    Li, Mu; Lu, Yanmeng; Han, Shuaihu; Wu, Zhuobin; Chen, Jiajing; Liu, Zhexing; Cao, Lei

    2015-08-01

    We proposed a new stitching method based on sift features to obtain an enlarged view of transmission electron microscopic (TEM) images with a high resolution. The sift features were extracted from the images, which were then combined with fitted polynomial correction field to correct the images, followed by image alignment based on the sift features. The image seams at the junction were finally removed by Poisson image editing to achieve seamless stitching, which was validated on 60 local glomerular TEM images with an image alignment error of 62.5 to 187.5 nm. Compared with 3 other stitching methods, the proposed method could effectively reduce image deformation and avoid artifacts to facilitate renal biopsy pathological diagnosis.

  6. Optically oriented electron spin transmission across ferromagnet/semiconductor interfaces

    Science.gov (United States)

    Taniyama, T.; Suzuki, I.; Wada, E.; Shirahata, Y.; Naito, T.; Itoh, M.; Yamaguchi, M.

    2011-10-01

    Electron spin transmission across ferromagnetic metal/semiconductor interfaces with different ferromagnetic contacts, i.e., Fe and FeGa, is studied using optical spin orientation method. The bias dependence of spin dependent photocurrent, which is the difference between the photocurrents excited with left- and right- handed circularly polarized lights, is found to show a dip-like feature at -0.058 and 0.021 V for Fe and FeGa contacts, respectively. The origin of the bias dependence of the spin dependent photocurrent is discussed on the basis of the Breit-Wigner type resonant tunneling process via interface resonant states, comparing the results for the both contacts. The results also indicate that the control of interface states is crucial to achieve efficient spin filtering effect at the ferromagnet/semiconductor interfaces.

  7. Visualization and quantitative analysis of nanoparticles in the respiratory tract by transmission electron microscopy

    Directory of Open Access Journals (Sweden)

    Gehr Peter

    2007-11-01

    Full Text Available Abstract Nanotechnology in its widest sense seeks to exploit the special biophysical and chemical properties of materials at the nanoscale. While the potential technological, diagnostic or therapeutic applications are promising there is a growing body of evidence that the special technological features of nanoparticulate material are associated with biological effects formerly not attributed to the same materials at a larger particle scale. Therefore, studies that address the potential hazards of nanoparticles on biological systems including human health are required. Due to its large surface area the lung is one of the major sites of interaction with inhaled nanoparticles. One of the great challenges of studying particle-lung interactions is the microscopic visualization of nanoparticles within tissues or single cells both in vivo and in vitro. Once a certain type of nanoparticle can be identified unambiguously using microscopic methods it is desirable to quantify the particle distribution within a cell, an organ or the whole organism. Transmission electron microscopy provides an ideal tool to perform qualitative and quantitative analyses of particle-related structural changes of the respiratory tract, to reveal the localization of nanoparticles within tissues and cells and to investigate the 3D nature of nanoparticle-lung interactions. This article provides information on the applicability, advantages and disadvantages of electron microscopic preparation techniques and several advanced transmission electron microscopic methods including conventional, immuno and energy-filtered electron microscopy as well as electron tomography for the visualization of both model nanoparticles (e.g. polystyrene and technologically relevant nanoparticles (e.g. titanium dioxide. Furthermore, we highlight possibilities to combine light and electron microscopic techniques in a correlative approach. Finally, we demonstrate a formal quantitative, i.e. stereological

  8. Response prediction techniques and case studies of a path blocking system based on Global Transmissibility Direct Transmissibility method

    Science.gov (United States)

    Wang, Zengwei; Zhu, Ping; Zhao, Jianxuan

    2017-02-01

    In this paper, the prediction capabilities of the Global Transmissibility Direct Transmissibility (GTDT) method are further developed. Two path blocking techniques solely using the easily measured variables of the original system to predict the response of a path blocking system are generalized to finite element models of continuous systems. The proposed techniques are derived theoretically in a general form for the scenarios of setting the response of a subsystem to zero and of removing the link between two directly connected subsystems. The objective of this paper is to verify the reliability of the proposed techniques by finite element simulations. Two typical cases, the structural vibration transmission case and the structure-borne sound case, in two different configurations are employed to illustrate the validity of proposed techniques. The points of attention for each case have been discussed, and conclusions are given. It is shown that for the two cases of blocking a subsystem the proposed techniques are able to predict the new response using measured variables of the original system, even though operational forces are unknown. For the structural vibration transmission case of removing a connector between two components, the proposed techniques are available only when the rotational component responses of the connector are very small. The proposed techniques offer relative path measures and provide an alternative way to deal with NVH problems. The work in this paper provides guidance and reference for the engineering application of the GTDT prediction techniques.

  9. Development of wavelength-dispersive soft X-ray emission spectrometers for transmission electron microscopes--an introduction of valence electron spectroscopy for transmission electron microscopy.

    Science.gov (United States)

    Terauchi, Masami; Koike, Masato; Fukushima, Kurio; Kimura, Atsushi

    2010-01-01

    Two types of wavelength-dispersive soft X-ray spectrometers, a high-dispersion type and a conventional one, for transmission electron microscopes were constructed. Those spectrometers were used to study the electronic states of valence electrons (bonding electrons). Both spectrometers extended the acceptable energy regions to higher than 2000 eV. The best energy resolution of 0.08 eV was obtained for an Al L-emission spectrum by using the high-dispersion type spectrometer. By using the spectrometer, C K-emission of carbon allotropes, Cu L-emission of Cu(1-x)Zn(x) alloys and Pt M-emission spectra were presented. The FWHM value of 12 eV was obtained for the Pt Malpha-emission peak. The performance of the conventional one was also presented for ZnS and a section specimen of a multilayer device. W-M and Si-K emissions were clearly resolved. Soft X-ray emission spectroscopy based on transmission electron microscopy (TEM) has an advantage for obtaining spectra from a single crystalline specimen with a defined crystal setting. As an example of anisotropic soft X-ray emission, C K-emission spectra of single crystalline graphite with different crystal settings were presented. From the spectra, density of states of pi- and sigma-bondings were separately derived. These results demonstrated a method to analyse the electronic states of valence electrons of materials in the nanometre scale based on TEM.

  10. Localization of human immunodeficiency virus antigens in infected cells by scanning/transmission-immunogold techniques

    Energy Technology Data Exchange (ETDEWEB)

    Herrera, M.I.; Santa Maria, I.; de Andres, R.; Najera, R.

    1988-01-01

    An application of high resolution scanning/transmission electron microscopy (STEM) and gold-labelling techniques for the rapid detection of human immunodeficiency virus (HIV) in infected cells has been developed. Experimental in vitro studies for detecting two HIV structural proteins, gp41 and p17, were performed following an indirect labeling procedure that uses monoclonal anti-p17 and anti-gp41 antibodies as primary antibodies and 40 nm gold-linked goat antimouse IgG as secondary antibodies. The cells were then studied by STEM in the scanning mode. Unambiguous localization of the viral antigens was possible by combining the three-dimensional image provided by the secondary electron image and the atomic number-dependent backscattered electron image for the identification of the gold marker. This technique combines both the morphological information and the rapid procedures of scanning electron microscopy with the precise and sensitive antigen detection provided by the use of STEM and immunological methods. The preliminary results of its application to the study of peripheral blood mononuclear cells from four anti-HIV-seropositive patients showing the presence of specific labeling in all of them suggest that it might prove useful for early detection of HIV infection before seroconversion, as well as for quantitative studies.

  11. Environmental transmission electron microscopy for catalyst materials using a spherical aberration corrector

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, Seiji, E-mail: takeda@sanken.osaka-u.ac.jp; Kuwauchi, Yasufumi; Yoshida, Hideto

    2015-04-15

    Atomic resolution has been obtained using environmental transmission electron microscopy (ETEM) by installing a spherical aberration corrector (Cs-corrector) on the objective lens. Simultaneously, the technology for controlling the environment around a specimen in ETEM has advanced significantly in the past decade. Quantification methodology has recently been established for deriving relevant experimental data in catalyst materials from substantial and systematic ETEM observation at the atomic scale. With this background, this paper summarizes aspects of the evolutional microscopy technique: necessary conditions for atomic resolution in ETEM; reduction of the scattering of electrons by the medium surrounding a specimen; and an environmental cell for structural imaging of a crystalline specimen. The high spatial resolution of a Cs-corrected ETEM is demonstrated for different observation conditions. After statistical analysis combined with numerical image analysis of ETEM data is briefly described, the recent applications of the Cs-corrected ETEM to catalyst materials are reviewed. For gold nanoparticulate catalysts, the structural information on the reaction sites and adsorption sites are deduced. For Pt nanoparticulate catalysts, ETEM studies elucidate the correlation between the catalytic activity and the morphology of the nanoparticles. These studies also reveal oxidation and reduction on the topmost Pt surface layer at the atomic scale. Finally, current issues and the future perspectives of Cs-corrected ETEM are summarized, including the reproducibility of ETEM observation data, the control of environments, the critical evaluation of electron irradiation effects, the full implementation of transmission electron microscopy technology in ETEM, and the safety issues for an ETEM laboratory. - Highlights: • Advancement of Cs corrected environmental transmission electron microscopy. • Structural determination of catalyst materials in reaction environments.

  12. Amyloid Structure and Assembly: Insights from Scanning Transmission Electron Microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Goldsbury, C.; Wall, J.; Baxa, U.; Simon, M. N.; Steven, A. C.; Engel, A.; Aebi, U.; Muller, S. A.

    2011-01-01

    Amyloid fibrils are filamentous protein aggregates implicated in several common diseases such as Alzheimer's disease and type II diabetes. Similar structures are also the molecular principle of the infectious spongiform encephalopathies such as Creutzfeldt-Jakob disease in humans, scrapie in sheep, and of the so-called yeast prions, inherited non-chromosomal elements found in yeast and fungi. Scanning transmission electron microscopy (STEM) is often used to delineate the assembly mechanism and structural properties of amyloid aggregates. In this review we consider specifically contributions and limitations of STEM for the investigation of amyloid assembly pathways, fibril polymorphisms and structural models of amyloid fibrils. This type of microscopy provides the only method to directly measure the mass-per-length (MPL) of individual filaments. Made on both in vitro assembled and ex vivo samples, STEM mass measurements have illuminated the hierarchical relationships between amyloid fibrils and revealed that polymorphic fibrils and various globular oligomers can assemble simultaneously from a single polypeptide. The MPLs also impose strong constraints on possible packing schemes, assisting in molecular model building when combined with high-resolution methods like solid-state nuclear magnetic resonance (NMR) and electron paramagnetic resonance (EPR).

  13. Materials characterisation by angle-resolved scanning transmission electron microscopy

    Science.gov (United States)

    Müller-Caspary, Knut; Oppermann, Oliver; Grieb, Tim; Krause, Florian F.; Rosenauer, Andreas; Schowalter, Marco; Mehrtens, Thorsten; Beyer, Andreas; Volz, Kerstin; Potapov, Pavel

    2016-11-01

    Solid-state properties such as strain or chemical composition often leave characteristic fingerprints in the angular dependence of electron scattering. Scanning transmission electron microscopy (STEM) is dedicated to probe scattered intensity with atomic resolution, but it drastically lacks angular resolution. Here we report both a setup to exploit the explicit angular dependence of scattered intensity and applications of angle-resolved STEM to semiconductor nanostructures. Our method is applied to measure nitrogen content and specimen thickness in a GaNxAs1‑x layer independently at atomic resolution by evaluating two dedicated angular intervals. We demonstrate contrast formation due to strain and composition in a Si- based metal-oxide semiconductor field effect transistor (MOSFET) with GexSi1‑x stressors as a function of the angles used for imaging. To shed light on the validity of current theoretical approaches this data is compared with theory, namely the Rutherford approach and contemporary multislice simulations. Inconsistency is found for the Rutherford model in the whole angular range of 16–255 mrad. Contrary, the multislice simulations are applicable for angles larger than 35 mrad whereas a significant mismatch is observed at lower angles. This limitation of established simulations is discussed particularly on the basis of inelastic scattering.

  14. Microwave Transmission Measurement of the Electron Cloud Density in the Positron Ring of PEP-II

    CERN Document Server

    Pivi, M T F; Byrd, J; De Santis, S; Sonnad, K G; Caspers, Friedhelm; Kroyer, T; Roncarolo, F

    2008-01-01

    Clouds of electrons in the vacuum chambers of accelerators of positively charged particle beams present a serious limitation for operation of these machines at high currents. Because of the size of these accelerators, it is difficult to probe the low energy electron clouds over substantial lengths of the beam pipe. We applied a novel technique to directly measure the electron cloud density via the phase shift induced in a TE wave which is independently excited and transmitted over a straight section of the accelerator. The modulation in the wave transmission which appear to increase in depth when the clearing solenoids are switched off, seem to be directly correlated to the electron cloud density in the section. Furthermore, we expect a larger phase shift of a wave transmitted through magnetic dipole field regions if the transmitted wave couples with the gyration motion of the electrons. We have used this technique to measure the average electron cloud density (ECD) specifically for the first time in magnetic...

  15. Transmission Electron Diffraction Studies of Xenon Adsorbed on Graphite.

    Science.gov (United States)

    Faisal, A. Q. D.

    1987-09-01

    Available from UMI in association with The British Library. Adsorption studies of xenon on graphite were performed using the Hitachi HU-11B Transmission Electron Microscope (TEM). It has been used as a Transmission High Energy Electron Diffraction (THEED) camera. This has been modified to include an Ultra High Vacuum (UHV) environmental chamber. This chamber was isolated from the microscope vacuum by two 400 μm diameter differentially pumped apertures. Pressures of {~}10 ^{-6} torr and {~ }10^{-9} torr were achieved inside the microscope column and the environmental chamber respectively. The chamber was fitted with a new sample holder designed with double "O" rings. The sample was cooled with liquid helium. Previous THEED experiments by Venables et al and Schabes-Retchkiman and Venables revealed the presence of a 2D-solid incommensurate (I)-commensurate (C) phase transition as the temperature is lowered. These results were confirmed and extended in the present work. Hong et al have recently interpreted their X-ray diffraction experiments as showing an incommensurate-striped domain phase transition at {~}65rm K. No evidence was found for the existence of a striped domain structure on any part of the xenon phase diagram studied. Experiments of xenon adsorbed on the basal plane (0001) of graphite were carried out at pressures from {~}1.5 times 10^{-5} torr to {~}1.8 times 10^{-8} torr over a temperature range from 55K^.90K. A set of lattice parameter (misfit) measurements were made as a function of temperature at constant pressure with an accuracy of +/-0.1% rather than +/-0.3% previously obtained. The misfit data was fitted to a power law formula, i.e. misfit m = B_{rm o} (rm T - rm T_{rm o})^{rm A} , where A is a constant and equal to 0.8. It was found that B_{rm o} and T_{rm o} are functions of log(P). The data fell into two groups corresponding to two phase transitions. The same power law was used for both sets of data. Two transitions were found, one is I-C and

  16. Below band-gap laser ablation of diamond for transmission electron microscopy

    Science.gov (United States)

    George, T.; Foote, M. C.; Vasquez, R. P.; Fortier, E. P.; Posthill, J. B.

    1993-01-01

    A 248 nm excimer laser was used to thin naturally occurring type 1a diamond substrates at normal and glancing (22 deg) incidence. Perforation of a 250-micron-thick substrate was achieved in about 15 min at normal incidence. While the substrate thinned at glancing incidence was found to have large electron-transparent areas, that thinned at normal incidence required additional argon-ion milling to achieve electron transparency. X-ray photoelectron spectroscopy of the back surface of the diamond failed to detect any graphite or glassy carbon, confirming that damage due to laser ablation occurs only at the incident surface. Samples prepared using this technique imaged in the transmission electron microscope were observed to have retained the nitrogen platelets characteristic of such type 1a diamonds.

  17. In situ transmission electron microscopy observations of individually selected freestanding carbon nanotubes during field emission

    Energy Technology Data Exchange (ETDEWEB)

    Kaiser, Monja [Philips Research Laboratories, High Tech Campus 11, 5656 AE Eindhoven (Netherlands)]. E-mail: m.kaiser@philips.com; Doytcheva, Maya [Philips Research Laboratories, High Tech Campus 11, 5656 AE Eindhoven (Netherlands); Verheijen, Marcel [Philips Research Laboratories, High Tech Campus 11, 5656 AE Eindhoven (Netherlands); Jonge, Niels de [Materials Science and Technology Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6030 (United States)

    2006-08-15

    For the successful application of carbon nanotubes (CNTs) as electron sources in various applications it is important to understand the relation between the morphology of the CNT and its emission properties. A method was developed to study individual, freestanding and pre-selected CNTs with high-resolution transmission electron microscopy (TEM). The technique provided important parameters of the CNT, such as the number of carbon walls and the nature of its apex. The resolution with which the freestanding apices were imaged depended linearly on the ratio of the length and the radius. CNTs were also imaged in situ in the TEM while emitting electrons. It was found that the structure of a CNT was highly stable below a certain threshold emission current of typically 2 {mu}A, while various structural changes occurred above the threshold, leading to either damaging or repair of the structure at the apex of the CNT.

  18. Approaches to modelling irradiation-induced processes in transmission electron microscopy.

    Science.gov (United States)

    Skowron, Stephen T; Lebedeva, Irina V; Popov, Andrey M; Bichoutskaia, Elena

    2013-08-07

    The recent progress in high-resolution transmission electron microscopy (HRTEM) has given rise to the possibility of in situ observations of nanostructure transformations and chemical reactions induced by electron irradiation. In this article we briefly summarise experimental observations and discuss in detail atomistic modelling of irradiation-induced processes in HRTEM, as well as mechanisms of such processes recognised due to modelling. Accurate molecular dynamics (MD) techniques based on first principles or tight-binding models are employed in the analysis of single irradiation-induced events, and classical MD simulations are combined with a kinetic Monte Carlo algorithm to simulate continuous irradiation of nanomaterials. It has been shown that sulphur-terminated graphene nanoribbons are formed inside carbon nanotubes as a result of an irradiation-selective chemical reaction. The process of fullerene formation in HRTEM during continuous electron irradiation of a small graphene flake has been simulated, and mechanisms driving this transformation analysed.

  19. Below band-gap laser ablation of diamond for transmission electron microscopy

    Science.gov (United States)

    George, T.; Foote, M. C.; Vasquez, R. P.; Fortier, E. P.; Posthill, J. B.

    1993-01-01

    A 248 nm excimer laser was used to thin naturally occurring type 1a diamond substrates at normal and glancing (22 deg) incidence. Perforation of a 250-micron-thick substrate was achieved in about 15 min at normal incidence. While the substrate thinned at glancing incidence was found to have large electron-transparent areas, that thinned at normal incidence required additional argon-ion milling to achieve electron transparency. X-ray photoelectron spectroscopy of the back surface of the diamond failed to detect any graphite or glassy carbon, confirming that damage due to laser ablation occurs only at the incident surface. Samples prepared using this technique imaged in the transmission electron microscope were observed to have retained the nitrogen platelets characteristic of such type 1a diamonds.

  20. Transmission Electron Microscopy of Magnetite Plaquettes in Orgueil

    Science.gov (United States)

    Chan, Q. H. S.; Han, J.; Zolensky, M.

    2016-01-01

    Magnetite sometimes takes the form of a plaquette - barrel-shaped stack of magnetite disks - in carbonaceous chondrites (CC) that show evidence of aqueous alteration. The asymmetric nature of the plaquettes caused Pizzarello and Groy to propose magnetite plaquettes as a naturally asymmetric mineral that can indroduce symmetry-breaking in organic molecules. Our previous synchrotron X-ray computed microtomography (SXRCT) and electron backscatter diffraction (EBSD) analyses of the magnetite plaquettes in fifteen CCs indicate that magnetite plaquettes are composed of nearly parallel discs, and the crystallographic orientations of the discs change around a rotational axis normal to the discs surfaces. In order to further investigate the nanostructures of magnetite plaquettes, we made two focused ion beam (FIB) sections of nine magnetite plaquettes from a thin section of CI Orgueil for transmission electron microscope (TEM) analysis. The X-ray spectrum imaging shows that the magnetite discs are purely iron oxide Fe3O4 (42.9 at% Fe and 57.1 at% O), which suggest that the plaquettes are of aqueous origin as it is difficult to form pure magnetite as a nebular condensate. The selected area electron diffraction (SAED) patterns acquired across the plaquettes show that the magnetite discs are single crystals. SEM and EBSD analyses suggest that the planar surfaces of the magnetite discs belong to the {100} planes of the cubic inverse spinel structure, which are supported by our TEM observations. Kerridge et al. suggested that the epitaxial relationship between magnetite plaquette and carbonate determines the magnetite face. However, according to our TEM observation, the association of magnetite with porous networks of phyllosilicate indicates that the epitaxial relationship with carbonate is not essential to the formation of magnetite plaquettes. It was difficult to determine the preferred rotational orientation of the plaquettes due to the symmetry of the cubic structure

  1. Spatial Resolution in Scanning Electron Microscopy and Scanning Transmission Electron Microscopy Without a Specimen Vacuum Chamber.

    Science.gov (United States)

    Nguyen, Kayla X; Holtz, Megan E; Richmond-Decker, Justin; Muller, David A

    2016-08-01

    A long-standing goal of electron microscopy has been the high-resolution characterization of specimens in their native environment. However, electron optics require high vacuum to maintain an unscattered and focused probe, a challenge for specimens requiring atmospheric or liquid environments. Here, we use an electron-transparent window at the base of a scanning electron microscope's objective lens to separate column vacuum from the specimen, enabling imaging under ambient conditions, without a specimen vacuum chamber. We demonstrate in-air imaging of specimens at nanoscale resolution using backscattered scanning electron microscopy (airSEM) and scanning transmission electron microscopy. We explore resolution and contrast using Monte Carlo simulations and analytical models. We find that nanometer-scale resolution can be obtained at gas path lengths up to 400 μm, although contrast drops with increasing gas path length. As the electron-transparent window scatters considerably more than gas at our operating conditions, we observe that the densities and thicknesses of the electron-transparent window are the dominant limiting factors for image contrast at lower operating voltages. By enabling a variety of detector configurations, the airSEM is applicable to a wide range of environmental experiments including the imaging of hydrated biological specimens and in situ chemical and electrochemical processes.

  2. Nanoparticles and pop-off technique for electron microscopy: a known technique for a new purpose.

    Science.gov (United States)

    Lehmbecker, Annika; Rittinghausen, Susanne; Rohn, Kerstin; Baumgärtner, Wolfgang; Schaudien, Dirk

    2014-08-01

    Because of the size of the nanoparticles, their detection and exact anatomical localization in tissue samples are very difficult. Consequently, suitable methods are needed to prove their presence, especially co-localized to histological lesions. Therefore, the aim of this study was to investigate whether nanoparticles were detectable in specimens after reprocessing samples from glass slides using the pop-off technique. Tissue slides containing agglomerates of titanium dioxide nanoparticles already visible on a light microscopic level and amorphous silicium dioxide (SiO2) particles not observable in tissue slides were reprocessed. Furthermore, cytospots of bronchoalveolar lavage acquired from rats that previously inhaled carbon nanotubes were used. After reprocessing the samples, they were investigated using transmission electron microscopy. In all the reprocessed samples, the respective nanoparticles were detectable. Even the light microscopically invisible amorphous SiO2 particles were observed as electron dense structures. Titanium and silicium were additionally confirmed in the respective nanoparticles by energy-dispersive X-ray spectroscopy (EDX). In summary, the pop-off technique represents a fast and easy way to detect nanoparticles in histological sections. This enables further characterization of these particles by additional techniques such as EDX, and their direct correlation with light microscopic lesions at exactly the same location is investigated.

  3. The formation and interpretation of defect images from crystalline materials in a scanning transmission electron microscope.

    Science.gov (United States)

    Maher, D M; Joy, D C

    1976-06-01

    The technique of scanning transmission electron microscopy (STEM) has been employed usefully in studies of amorphous materials, and the theory of image formation and interpretation in this case has been well developed. Less attention has been given to the practical and theoretical problems associated with the use of STEM for the examination of crystalline materials. In this case the contrast mechanisms are dominated by Bragg diffraction and so they are quite different from those occurring in amorphous substances. In this paper practical techniques for the observation and interpretation of contrast from defects in crystalline materials are discussed. It is shown that whilst images of defects are obtained readily under all typical STEM operating conditions, the form of the image and the information it contains varies with the angle subtended at the specimen by the detector. If this angle is too large significant image modifications relative to the "conventional" transmission electron microscope case may occur and the resolution of the image may degrade. If this angle is too small, then signal to noise considerations make an interpretation of the image difficult. In this paper we indicate how the detector angle may be chosen correctly, and also present techniques for setting up a STEM instrument for imaging a crystalline material containing lattice defects.

  4. Multiscale phase mapping of LiFePO4-based electrodes by transmission electron microscopy and electron forward scattering diffraction.

    Science.gov (United States)

    Robert, Donatien; Douillard, Thierry; Boulineau, Adrien; Brunetti, Guillaume; Nowakowski, Pawel; Venet, Denis; Bayle-Guillemaud, Pascale; Cayron, Cyril

    2013-12-23

    LiFePO4 and FePO4 phase distributions of entire cross-sectioned electrodes with various Li content are investigated from nanoscale to mesoscale, by transmission electron microscopy and by the new electron forward scattering diffraction technique. The distributions of the fully delithiated (FePO4) or lithiated particles (LiFePO4) are mapped on large fields of view (>100 × 100 μm(2)). Heterogeneities in thin and thick electrodes are highlighted at different scales. At the nanoscale, the statistical analysis of 64 000 particles unambiguously shows that the small particles delithiate first. At the mesoscale, the phase maps reveal a core-shell mechanism at the scale of the agglomerates with a preferential pathway along the electrode porosities. At larger scale, lithiation occurs in thick electrodes "stratum by stratum" from the surface in contact with electrolyte toward the current collector.

  5. A Monte Carlo investigation of contaminant electrons due to a novel in vivo transmission detector.

    Science.gov (United States)

    Asuni, G; Jensen, J M; McCurdy, B M C

    2011-02-21

    A novel transmission detector (IBA Dosimetry, Germany) developed as an IMRT quality assurance tool, intended for in vivo patient dose measurements, is studied here. The goal of this investigation is to use Monte Carlo techniques to characterize treatment beam parameters in the presence of the detector and to compare to those of a plastic block tray (a frequently used clinical device). Particular attention is paid to the impact of the detector on electron contamination model parameters of two commercial dose calculation algorithms. The linac head together with the COMPASS transmission detector (TRD) was modeled using BEAMnrc code. To understand the effect of the TRD on treatment beams, the contaminant electron fluence, energy spectra, and angular distributions at different SSDs were analyzed for open and non-open (i.e. TRD and block tray) fields. Contaminant electrons in the BEAMnrc simulations were separated according to where they were created. Calculation of surface dose and the evaluation of contributions from contaminant electrons were performed using the DOSXYZnrc user code. The effect of the TRD on contaminant electrons model parameters in Eclipse AAA and Pinnacle(3) dose calculation algorithms was investigated. Comparisons of the fluence of contaminant electrons produced in the non-open fields versus open field show that electrons created in the non-open fields increase at shorter SSD, but most of the electrons at shorter SSD are of low energy with large angular spread. These electrons are out-scattered or absorbed in air and contribute less to surface dose at larger SSD. Calculated surface doses with the block tray are higher than those with the TRD. Contribution of contaminant electrons to dose in the buildup region increases with increasing field size. The additional contribution of electrons to surface dose increases with field size for TRD and block tray. The introduction of the TRD results in a 12% and 15% increase in the Gaussian widths used in the

  6. Polishing methods for metallic and ceramic transmission electron microscopy specimens: Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Kestel, B.J.

    1986-03-01

    In recent years, the increasing sophistication of transmission electron microscope (TEM) studies of materials has necessitated more exacting methods of specimen preparation. The present report describes improved equipment and techniques for electropolishing and chemically polishing a wide variety of specimens. Many of the specimens used in developing or improving the techniques to be described were irradiated with heavy ions such as nickel or vanadium to study radiation damage. The high cost of these specimens increased the need for reproducible methods of initial preparation postirradiation processing, and final thinning for TEM examination. A technique was also developed to salvage specimens that had previously been thinned but were unusable for various reasons. Jet polishing is, in general, the method of choice for surface polishing, sectioning, and thinning. The older beaker electropolishing method is included in this report because it is inexpensive and simple, and gives some insight into how the more recent methods were developed.

  7. Transmission and scanning electron microscopy confirm that bone microstructure is similar in osteopenic and osteoporotic patients.

    Science.gov (United States)

    Gül, Orkun; Atik, O Sahap; Erdoğan, Deniz; Göktaş, Güleser; Elmas, Ciğdem

    2013-01-01

    The objective was to confirm the finding of "Bone microstructure is similar in osteopenic and osteoporotic patients with femoral neck fracture." obtained in previous "light microscopy study", which was new and important data. Fourteen patients (5 males, 9 females) who were admitted with proximal femoral fracture following low energy trauma (patients who participated in the light microscopy study) were included. The patients were divided into two groups based on the bone mineral density (BMD) measurement, including osteopenic group (n=7, mean age 69 years; range 63 to 74 years) and osteoporotic group (n=7, mean age 74.1 years; range 67 to 78 years). Cortical and trabecular bone samples were taken from the patients who underwent endoprosthesis during partial hip arthroplasty and these samples were analyzed using transmission electron microscopy and scanning electron microscopy evaluations which are more sophisticated higher resolution techniques. The mean cortical bone thickness was 3622.14 mm in osteopenic group and 2323.14 mm in osteoporotic group (pelectron microscopy and scanning electron microscopy evaluations revealed similar findings for both groups. Although a significant difference in cortical thickness was found between the groups, transmission and scanning electron microscopy confirmed that bone microstructure shared similar characteristics in osteopenic and osteoporotic patients with low-energy femoral neck fracture, as it was in previous light microscopy study.

  8. Advanced coding techniques for few mode transmission systems.

    Science.gov (United States)

    Okonkwo, Chigo; van Uden, Roy; Chen, Haoshuo; de Waardt, Huug; Koonen, Ton

    2015-01-26

    We experimentally verify the advantage of employing advanced coding schemes such as space-time coding and 4 dimensional modulation formats to enhance the transmission performance of a 3-mode transmission system. The performance gain of space-time block codes for extending the optical signal-to-noise ratio tolerance in multiple-input multiple-output optical coherent spatial division multiplexing transmission systems with respect to single-mode transmission performance are evaluated. By exploiting the spatial diversity that few-mode-fibers offer, with respect to single mode fiber back-to-back performance, significant OSNR gains of 3.2, 4.1, 4.9, and 6.8 dB at the hard-decision forward error correcting limit are demonstrated for DP-QPSK 8, 16 and 32 QAM, respectively. Furthermore, by employing 4D constellations, 6 × 28Gbaud 128 set partitioned quadrature amplitude modulation is shown to outperform conventional 8 QAM transmission performance, whilst carrying an additional 0.5 bit/symbol.

  9. Improved Hilbert phase contrast for transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Koeck, Philip J.B.

    2015-07-15

    Hilbert phase contrast has been recognized as a means of recording high resolution images with high contrast using a transmission electron microscope. This imaging mode could be used to image typical phase objects such as unstained biological molecules or cryo sections of biological tissue. According to the original proposal by (Danev et al., 2002) the Hilbert phase plate applies a phase shift of π to approximately half the focal plane (for example the right half excluding the central beam) and an image is recorded at Gaussian focus. After correction for the inbuilt asymmetry of differential phase contrast this image will have an almost perfect contrast transfer function (close to 1) from the lowest spatial frequency up to a maximum resolution determined by the wave length and spherical aberration of the microscope. In this paper I present theory and simulations showing that this maximum spatial frequency can be increased considerably almost without loss of contrast by using a Hilbert phase plate of half the thickness, leading to a phase shift of π/2, and recording images at Scherzer defocus. The maximum resolution can be improved even more by imaging at extended Scherzer defocus, though at the cost of contrast loss at lower spatial frequencies. - Highlights: • In this paper I present theory and simulations for a Hilbert phase plate that phase shifts the electron wave by π/2 instead of π while images are recorded close to Scherzer defocus instead of Gaussian focus. • I show that the point resolution for this new imaging mode is considerably higher without loss of contrast. • An additional advantage lies in the reduced thickness of the phase plate which leads to reduced inelastic scattering in the phase plate and less noise.

  10. Visualizing aquatic bacteria by light and transmission electron microscopy.

    Science.gov (United States)

    Silva, Thiago P; Noyma, Natália P; Duque, Thabata L A; Gamalier, Juliana P; Vidal, Luciana O; Lobão, Lúcia M; Chiarini-Garcia, Hélio; Roland, Fábio; Melo, Rossana C N

    2014-01-01

    The understanding of the functional role of aquatic bacteria in microbial food webs is largely dependent on methods applied to the direct visualization and enumeration of these organisms. While the ultrastructure of aquatic bacteria is still poorly known, routine observation of aquatic bacteria by light microscopy requires staining with fluorochromes, followed by filtration and direct counting on filter surfaces. Here, we used a new strategy to visualize and enumerate aquatic bacteria by light microscopy. By spinning water samples from varied tropical ecosystems in a cytocentrifuge, we found that bacteria firmly adhere to regular slides, can be stained by fluorochoromes with no background formation and fast enumerated. Significant correlations were found between the cytocentrifugation and filter-based methods. Moreover, preparations through cytocentrifugation were more adequate for bacterial viability evaluation than filter-based preparations. Transmission electron microscopic analyses revealed a morphological diversity of bacteria with different internal and external structures, such as large variation in the cell envelope and capsule thickness, and presence or not of thylakoid membranes. Our results demonstrate that aquatic bacteria represent an ultrastructurally diverse population and open avenues for easy handling/quantification and better visualization of bacteria by light microscopy without the need of filter membranes.

  11. Transmission electron microscopy (TEM) study of minerals in coal

    Energy Technology Data Exchange (ETDEWEB)

    Hsieh, Kuang-Chien

    1982-01-01

    Minerals in eight coals from different mines were characterized in the micron-size range by using analytical transmission electron microscopy. Specimens were thinned by ion-milling wafers cut from these coals; a cold stage cooled by liquid nitrogen was used to reduce thermal degradation of the minerals by the ion-beam. Different mineral compounds were observed in different coals. The major minerals are clays, sulfides, oxides, carbonates and some minor-element-bearing phosphates. Clays (kaolinite, illite and others) have been most commonly found as either flat sheets or round globules. Iron sulfide was mostly found in the No. 5 and No. 6 coals from Illinois, distributed as massive polycrystals, as clusters of single crystals (framboids) or as isolated single crystals with size range down to some 0.25 microns. Other sulfides and some oxides were found in other coals with particle size as small as some 200 angstroms. Quartz, titanium oxides and many other carbonates and phosphate compounds were also characterized. Brief TEM work in the organic mass of coal was also introduced to study the nature of the coal macerals.

  12. TRANSMISSION ELECTRON MICROSCOPY STUDY OF HELIUM BEARING FUSION WELDS

    Energy Technology Data Exchange (ETDEWEB)

    Tosten, M; Michael Morgan, M

    2008-12-12

    A transmission electron microscopy (TEM) study was conducted to characterize the helium bubble distributions in tritium-charged-and-aged 304L and 21Cr-6Ni-9Mn stainless steel fusion welds containing approximately 150 appm helium-3. TEM foils were prepared from C-shaped fracture toughness test specimens containing {delta} ferrite levels ranging from 4 to 33 volume percent. The weld microstructures in the low ferrite welds consisted mostly of austenite and discontinuous, skeletal {delta} ferrite. In welds with higher levels of {delta} ferrite, the ferrite was more continuous and, in some areas of the 33 volume percent sample, was the matrix/majority phase. The helium bubble microstructures observed were similar in all samples. Bubbles were found in the austenite but not in the {delta} ferrite. In the austenite, bubbles had nucleated homogeneously in the grain interiors and heterogeneously on dislocations. Bubbles were not found on any austenite/austenite grain boundaries or at the austenite/{delta} ferrite interphase interfaces. Bubbles were not observed in the {delta} ferrite because of the combined effects of the low solubility and rapid diffusion of tritium through the {delta} ferrite which limited the amount of helium present to form visible bubbles.

  13. Probing electron beam effects with chemoresistive nanosensors during in situ environmental transmission electron microscopy

    Science.gov (United States)

    Steinhauer, S.; Wang, Z.; Zhou, Z.; Krainer, J.; Köck, A.; Nordlund, K.; Djurabekova, F.; Grammatikopoulos, P.; Sowwan, M.

    2017-02-01

    We report in situ and ex situ fabrication approaches to construct p-type (CuO) and n-type (SnO2) metal oxide nanowire devices for operation inside an environmental transmission electron microscope (TEM). By taking advantage of their chemoresistive properties, the nanowire devices were employed as sensitive probes for detecting reactive species induced by the interactions of high-energy electrons with surrounding gas molecules, in particular, for the case of O2 gas pressures up to 20 mbar. In order to rationalize our experimental findings, a computational model based on the particle-in-cell method was implemented to calculate the spatial distributions of scattered electrons and ionized oxygen species in the environmental TEM. Our approach enables the a priori identification and qualitative measurement of undesirable beam effects, paving the way for future developments related to their mitigation.

  14. The generalized transmission matrix for electron-wave-optics through biased heterostructures: Quantum device applications

    Science.gov (United States)

    Kan'an, A. M.; Puri, A.

    1994-01-01

    The transmission matrix approach is generalized to calculate the transmission probability of obliquely incident electrons through arbitrary shape potential profiles. Transmission probability is obtained as a function of the electron energy, the angle of incidence, and the applied voltage across the structure. Applications to electron waveguide and quantum resonant tunneling are outlined. Numerical results are presented for angle dependent resonant tunneling through biased multibarrier GaAs-AlxGa1-xAs heterostructures. As a consequence, various novel quantum devices, i.e., high speed switch, tunable electron wave filter, and electron wave beam splitter are proposed.

  15. Carbon contamination in scanning transmission electron microscopy and its impact on phase-plate applications.

    Science.gov (United States)

    Hettler, Simon; Dries, Manuel; Hermann, Peter; Obermair, Martin; Gerthsen, Dagmar; Malac, Marek

    2017-05-01

    We analyze electron-beam induced carbon contamination in a transmission electron microscope. The study is performed on thin films potentially suitable as phase plates for phase-contrast transmission electron microscopy. Electron energy-loss spectroscopy and phase-plate imaging is utilized to analyze the contamination. The deposited contamination layer is identified as a graphitic carbon layer which is not prone to electrostatic charging whereas a non-conductive underlying substrate charges. Several methods that inhibit contamination are evaluated and the impact of carbon contamination on phase-plate imaging is discussed. The findings are in general interesting for scanning transmission electron microscopy applications.

  16. Scanning Transmission X-Ray, Laser Scanning, and Transmission Electron Microscopy Mapping of the Exopolymeric Matrix of Microbial Biofilms

    OpenAIRE

    Lawrence, J. R.; Swerhone, G. D. W.; Leppard, G. G.; T. Araki; Zhang, X.; West, M. M.; A. P. Hitchcock

    2003-01-01

    Confocal laser scanning microscopy (CLSM), transmission electron microscopy (TEM), and soft X-ray scanning transmission X-ray microscopy (STXM) were used to map the distribution of macromolecular subcomponents (e.g., polysaccharides, proteins, lipids, and nucleic acids) of biofilm cells and matrix. The biofilms were developed from river water supplemented with methanol, and although they comprised a complex microbial community, the biofilms were dominated by heterotrophic bacteria. TEM provid...

  17. Electronic publications, a useful technique for astronomy outreach

    Science.gov (United States)

    Stavinschi, M.; Mosoia, C.

    2012-09-01

    Thanks to modern technology, astronomy can be communicated to the public through a variety of techniques, from classic conferences (also upgraded to the video projectors, etc.) to TV, print media and social media platforms such as Facebook, Twitter, Linkedin, MySpace, etc. We are going to present advantages of electronic publishing, starting from informing the public with latest astronomy news, to providing a place for public debate. In an era of global crisis e-publishing is a must do, be it seen from the financially perspective, or the desired impact to the public. We are going to present a constant example of year electronic publication dedicated to promoting science and communication; also, the Science Communicators Network Interested in spreading the word of astronomy. The aim is to establish connections with all OEP participants with a view to know each other and try to work in common for the better message transmission to the public. Together, we might build a single platform with multiple educational results.

  18. Electron diffraction and high resolution transmission electron microscopy in the characterization of calcium phosphate precipitation from aqueous solutions under biomineralization conditions

    Directory of Open Access Journals (Sweden)

    Suvorova E. I.

    2001-01-01

    Full Text Available Calcium phosphate precipitation obtained from aqueous solutions at room and body temperature and pH 5.5-7.5 were investigated by high-resolution transmission electron microscopy (HRTEM, transmission electron diffraction, scanning electron microscopy (SEM and X-ray diffraction (XRD. Supersaturated solutions of calcium phosphates were prepared by different methods of mixing of the stock solutions: diffusion-controlled mixing in space, convection-controlled mixing on earth and forced mixing on earth and with typical physiological parameters (pH and temperature. Concentrations of the stock solutions, rate of solution mixing and duration of precipitation influence very strongly the chemical composition of the precipitation, the phase composition of individual crystals, their sizes, morphology and structure. Microdiffraction and HRTEM techniques showed an incontestable advantage on other techniques like SEM and XRD in the investigation of small particles and mixtures of calcium phosphates (hydroxyapatite and octacalcium phosphate with different proportions.

  19. Big Data Analytics for Scanning Transmission Electron Microscopy Ptychography

    Science.gov (United States)

    Jesse, S.; Chi, M.; Belianinov, A.; Beekman, C.; Kalinin, S. V.; Borisevich, A. Y.; Lupini, A. R.

    2016-05-01

    Electron microscopy is undergoing a transition; from the model of producing only a few micrographs, through the current state where many images and spectra can be digitally recorded, to a new mode where very large volumes of data (movies, ptychographic and multi-dimensional series) can be rapidly obtained. Here, we discuss the application of so-called “big-data” methods to high dimensional microscopy data, using unsupervised multivariate statistical techniques, in order to explore salient image features in a specific example of BiFeO3 domains. Remarkably, k-means clustering reveals domain differentiation despite the fact that the algorithm is purely statistical in nature and does not require any prior information regarding the material, any coexisting phases, or any differentiating structures. While this is a somewhat trivial case, this example signifies the extraction of useful physical and structural information without any prior bias regarding the sample or the instrumental modality. Further interpretation of these types of results may still require human intervention. However, the open nature of this algorithm and its wide availability, enable broad collaborations and exploratory work necessary to enable efficient data analysis in electron microscopy.

  20. Big Data Analytics for Scanning Transmission Electron Microscopy Ptychography.

    Science.gov (United States)

    Jesse, S; Chi, M; Belianinov, A; Beekman, C; Kalinin, S V; Borisevich, A Y; Lupini, A R

    2016-05-23

    Electron microscopy is undergoing a transition; from the model of producing only a few micrographs, through the current state where many images and spectra can be digitally recorded, to a new mode where very large volumes of data (movies, ptychographic and multi-dimensional series) can be rapidly obtained. Here, we discuss the application of so-called "big-data" methods to high dimensional microscopy data, using unsupervised multivariate statistical techniques, in order to explore salient image features in a specific example of BiFeO3 domains. Remarkably, k-means clustering reveals domain differentiation despite the fact that the algorithm is purely statistical in nature and does not require any prior information regarding the material, any coexisting phases, or any differentiating structures. While this is a somewhat trivial case, this example signifies the extraction of useful physical and structural information without any prior bias regarding the sample or the instrumental modality. Further interpretation of these types of results may still require human intervention. However, the open nature of this algorithm and its wide availability, enable broad collaborations and exploratory work necessary to enable efficient data analysis in electron microscopy.

  1. Development of a nanoindenter for in-situ transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Stach, Eric A.; Freeman, Tony; Minor, Andrew M.; Owen, Doug K.; Cumings, John; Wall, Mark A.; Chraska, Tomas; Hull, Robert; Morris Jr., J.W.; Zettl, A.; Dahmen, Ulrich

    2001-01-30

    In-situ transmission electron microscopy is an established experimental technique that permits direct observation of the dynamics and mechanisms of dislocation motion and deformation behavior. In this paper, we detail the development of a novel specimen goniometer that allows real time observations of the mechanical response of materials to indentation loads. The technology of the scanning tunneling microscope is adopted to allow nanometer scale positioning of a sharp, conductive diamond tip onto the edge of an electron transparent sample. This allows application of loads to nanometer-scale material volumes couple with simultaneous imaging of the material response. The emphasis in this paper is experimental and descriptive, with particular attention given to sample geometry and other technical requirements. Examples of the deformation of aluminum and titanium carbide as well as the fracture of silicon will be presented.

  2. On the optical stability of high-resolution transmission electron microscopes.

    Science.gov (United States)

    Barthel, J; Thust, A

    2013-11-01

    In the recent two decades the technique of high-resolution transmission electron microscopy experienced an unprecedented progress through the introduction of hardware aberration correctors and by the improvement of the achievable resolution to the sub-Ångström level. The important aspect that aberration correction at a given resolution requires also a well defined amount of optical stability has received little attention so far. Therefore we investigate the qualification of a variety of high-resolution electron microscopes to maintain an aberration corrected optical state in terms of an optical lifetime. We develop a comprehensive statistical framework for the estimation of the optical lifetime and find remarkably low values between tens of seconds and a couple of minutes. Probability curves are introduced, which inform the operator about the chance to work still in the fully aberration corrected state.

  3. Transmission electron microscopy study on ion-beam-synthesized amorphous Fe-Si thin layers

    Science.gov (United States)

    Naito, Muneyuki; Ishimaru, Manabu; Hirotsu, Yoshihiko; Valdez, James A.; Sickafus, Kurt E.

    2005-12-01

    Ion-beam-synthesized amorphous Fe-Si thin layers have been characterized using transmission electron microscopy (TEM) in combination with imaging plate techniques. Si single crystals with a (111) orientation were irradiated with 120keV Fe+ ions to a fluence of 4.0×1017cm-2 at cryogenic temperature (120K). Cross-sectional TEM observations indicated the formation of an amorphous bilayer on the topmost layer of the Si substrate. It was found that the upper layer is an amorphous Fe-Si with the composition, in terms of atomic ratio, of Fe /Si ˜1/2, while the lower one is an amorphous Si. Atomic pair-distribution functions extracted from microbeam electron diffraction patterns revealed that the nature of short-range order in amorphous Fe-Si thin layer can be well described by the atomic arrangements of crystalline iron silicides.

  4. Transmission Electron Microscopy of Iron Metal in Almahata Sitta Ureilite

    Science.gov (United States)

    Mikouchi, T.; Yubuta, K.; Sugiyama, K.; Aoyagi, Y.; Yasuhara, A.; Mihira, T.; Zolensky, M. E.; Goodrich, C. A.

    2013-01-01

    Almahata Sitta (AS) is a polymict breccia mainly composed of variable ureilite lithologies with small amounts of chondritic lithologies [1]. Fe metal is a common accessory phase in ureilites, but our earlier study on Fe metals in one of AS fragments (#44) revealed a unique mineralogy never seen in other ureilites [2,3]. In this abstract we report detailed transmission electron microscopy (TEM) on these metal grains to better understand the thermal history of ureilites. We prepared FIB sections of AS#44 by JEOL JIB-4000 from the PTS that was well characterized by SEM-EBSD in our earlier study [2]. The sections were then observed by STEM (JEOL JEM- 2100F). One of the FIB sections shows a submicron-sized symplectic intergrown texture composed of Fe metal (kamacite), Fe carbide (cohenite), Fe phosphide (schreibersite), and Fe sulfide (troilite). Each phase has an identical SAED pattern in spite of its complex texture, suggesting co-crystallization of all phases. This is probably caused by shock re-melting of pre-existing metal + graphite to form a eutectic-looking texture. The other FIB section is mostly composed of homogeneous Fe metal (93 wt% Fe, 5 wt% Ni, and 2 wt% Si), but BF-STEM images exhibited the presence of elongated lathy grains (approx. 2 microns long) embedded in the interstitial matrix. The SAED patterns from these lath grains could be indexed by alpha-Fe (bcc) while interstitial areas are gamma-Fe (fcc). The elongated alpha-Fe grains show tweed-like structures suggesting martensite transformation. Such a texture can be formed by rapid cooling from high temperature where gamma-Fe was stable. Subsequently alpha-Fe crystallized, but gamma-Fe remained in the interstitial matrix due to quenching from high temperature. This scenario is consistent with very rapid cooling history of ureilites suggested by silicate mineralogy.

  5. Transmission electron microscopy of subsolidus oxidation and weathering of olivine

    Science.gov (United States)

    Banfield, J.F.; Veblen, D.R.; Jones, B.F.

    1990-01-01

    Olivine crystals in basaltic andesites which crop out in the Abert Rim, south-central Oregon have been studied by high-resolution and analytical transmission electron microscopy. The observations reveal three distinct assemblages of alteration products that seem to correspond to three episodes of olivine oxidation. The olivine crystals contain rare, dense arrays of coherently intergrown Ti-free magnetite and inclusions of a phase inferred to be amorphous silica. We interpret this first assemblage to be the product of an early subsolidus oxidation event in the lava. The second olivine alteration assemblage contains complex ordered intergrowths on (001) of forsterite-rich olivine and laihunite (distorted olivine structure with Fe3+ charge balanced by vacancies). Based on experimental results for laihunite synthesis (Kondoh et al. 1985), these intergrowths probably formed by olivine oxidation between 400 and 800??C. The third episode of alteration involves the destruction of olivine by low-temperature hydrothermal alteration and weathering. Elongate etch-pits and channels in the margins of fresh olivine crystals contain semi-oriented bands of smectite. Olivine weathers to smectite and hematite, and subsequently to arrays of oriented hematite crystals. The textures resemble those reported by Eggleton (1984) and Smith et al. (1987). We find no evidence for a metastable phase intermediate between olivine and smectite ("M" - Eggleton 1984). The presence of laihunite exerts a strong control on the geometry of olivine weathering. Single laihunite layers and laihunite-forsteritic olivine intergrowths increase the resistance of crystals to weathering. Preferential development of channels between laihunite layers occurs where growth of laihunite produced compositional variations in olivine, rather than where coherency-strain is associated with laihunite-olivine interfaces. ?? 1990 Springer-Verlag.

  6. Bright-field scanning confocal electron microscopy using a double aberration-corrected transmission electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Peng; Behan, Gavin; Kirkland, Angus I. [Department of Materials, University of Oxford, Parks Road, Oxford OX1 3PH (United Kingdom); Nellist, Peter D., E-mail: peter.nellist@materials.ox.ac.uk [Department of Materials, University of Oxford, Parks Road, Oxford OX1 3PH (United Kingdom); Cosgriff, Eireann C.; D' Alfonso, Adrian J.; Morgan, Andrew J.; Allen, Leslie J. [School of Physics, University of Melbourne, Parkville, Victoria 3010 (Australia); Hashimoto, Ayako [Advanced Nano-characterization Center, National Institute for Materials Science (NIMS), 3-13 Sakura, Tsukuba 305-0003 (Japan); Takeguchi, Masaki [Advanced Nano-characterization Center, National Institute for Materials Science (NIMS), 3-13 Sakura, Tsukuba 305-0003 (Japan); High Voltage Electron Microscopy Station, NIMS, 3-13 Sakura, Tsukuba 305-0003 (Japan); Mitsuishi, Kazutaka [Advanced Nano-characterization Center, National Institute for Materials Science (NIMS), 3-13 Sakura, Tsukuba 305-0003 (Japan); Quantum Dot Research Center, NIMS, 3-13 Sakura, Tsukuba 305-0003 (Japan); Shimojo, Masayuki [High Voltage Electron Microscopy Station, NIMS, 3-13 Sakura, Tsukuba 305-0003 (Japan); Advanced Science Research Laboratory, Saitama Institute of Technology, 1690 Fusaiji, Fukaya 369-0293 (Japan)

    2011-06-15

    Scanning confocal electron microscopy (SCEM) offers a mechanism for three-dimensional imaging of materials, which makes use of the reduced depth of field in an aberration-corrected transmission electron microscope. The simplest configuration of SCEM is the bright-field mode. In this paper we present experimental data and simulations showing the form of bright-field SCEM images. We show that the depth dependence of the three-dimensional image can be explained in terms of two-dimensional images formed in the detector plane. For a crystalline sample, this so-called probe image is shown to be similar to a conventional diffraction pattern. Experimental results and simulations show how the diffracted probes in this image are elongated in thicker crystals and the use of this elongation to estimate sample thickness is explored. -- Research Highlights: {yields} The confocal probe image in a scanning confocal electron microscopy image reveals information about the thickness and height of the crystalline layer. {yields} The form of the contrast in a three-dimensional bright-field scanning confocal electron microscopy image can be explained in terms of the confocal probe image. {yields} Despite the complicated form of the contrast in bright-field scanning confocal electron microscopy, we see that depth information is transferred on a 10 nm scale.

  7. Picoliter Drop-On-Demand Dispensing for Multiplex Liquid Cell Transmission Electron Microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Patterson, Joseph P.; Parent, Lucas R.; Cantlon, Joshua; Eickhoff, Holger; Bared, Guido; Evans, James E.; Gianneschi, Nathan C.

    2016-05-03

    Abstract

    Liquid cell transmission electron microscopy (LCTEM) provides a unique insight into the dynamics of nanomaterials in solution. Controlling the addition of multiple solutions to the liquid cell remains a key hurdle in our ability to increase throughput and to study processes dependent on solution mixing including chemical reactions. Here, we report that a piezo dispensing technique allows for mixing of multiple solutions directly within the viewing area. This technique permits deposition of 50 pL droplets of various aqueous solutions onto the liquid cell window, before assembly of the cell in a fully controlled manner. This proof-of-concept study highlights the great potential of picoliter dispensing in combination with LCTEM for observing nanoparticle mixing in the solution phase and the creation of chemical gradients.

  8. Advances in cryogenic transmission electron microscopy for the characterization of dynamic self-assembling nanostructures.

    Science.gov (United States)

    Newcomb, Christina J; Moyer, Tyson J; Lee, Sungsoo S; Stupp, Samuel I

    2012-12-01

    Elucidating the structural information of nanoscale materials in their solvent-exposed state is crucial, as a result, cryogenic transmission electron microscopy (cryo-TEM) has become an increasingly popular technique in the materials science, chemistry, and biology communities. Cryo-TEM provides a method to directly visualize the specimen structure in a solution-state through a thin film of vitrified solvent. This technique complements X-ray, neutron, and light scattering methods that probe the statistical average of all species present; furthermore, cryo-TEM can be used to observe changes in structure over time. In the area of self-assembly, this tool has been particularly powerful for the characterization of natural and synthetic small molecule assemblies, as well as hybrid organic-inorganic composites. In this review, we discuss recent advances in cryogenic TEM in the context of self-assembling systems with emphasis on characterization of transitions observed in response to external stimuli.

  9. Bright-field scanning confocal electron microscopy using a double aberration-corrected transmission electron microscope.

    Science.gov (United States)

    Wang, Peng; Behan, Gavin; Kirkland, Angus I; Nellist, Peter D; Cosgriff, Eireann C; D'Alfonso, Adrian J; Morgan, Andrew J; Allen, Leslie J; Hashimoto, Ayako; Takeguchi, Masaki; Mitsuishi, Kazutaka; Shimojo, Masayuki

    2011-06-01

    Scanning confocal electron microscopy (SCEM) offers a mechanism for three-dimensional imaging of materials, which makes use of the reduced depth of field in an aberration-corrected transmission electron microscope. The simplest configuration of SCEM is the bright-field mode. In this paper we present experimental data and simulations showing the form of bright-field SCEM images. We show that the depth dependence of the three-dimensional image can be explained in terms of two-dimensional images formed in the detector plane. For a crystalline sample, this so-called probe image is shown to be similar to a conventional diffraction pattern. Experimental results and simulations show how the diffracted probes in this image are elongated in thicker crystals and the use of this elongation to estimate sample thickness is explored.

  10. Developing Assessment Techniques for Statewide Electronic Networks.

    Science.gov (United States)

    McClure, Charles R.; Bertot, John Carlo

    1996-01-01

    Explores several methods through which to evaluate statewide electronic networks, and discusses key issues and preliminary findings that affect the successful evaluation of statewide networked services. (Author/AEF)

  11. A Code Division Technique for Multiple Element Synthetic Aperture Transmission

    DEFF Research Database (Denmark)

    Gran, Fredrik; Jensen, Jørgen Arendt; Jakobsson, Andreas

    2004-01-01

    a method in which all transmitting centers can be excited at the same time and separated at the receiver. Hereby the benefits from traditional STA can be utilized and a high fframe rate can be maintained and the images are not influenced by motion artifacts. The different centers are excited using mutually....... The method was verified using Field II. A 7 MHz transducer was simulated with 128 receiving elements and 64 transmitting elements divided into subapertures so that 4 virtual transmission centers were formed. The point spread function was measured and the axial resolution was 0.2312 mm (-3dB) and 0.3083 mm...

  12. Understanding the structure of nanocatalysts with high resolution scanning/transmission electron microscopy

    Science.gov (United States)

    Francis, L. D.; Rivas, J.; José-Yacamán, M.

    2014-03-01

    Nanomaterials including nanoparticles, nanowires and nanotubes play an important role in heterogeneous catalysis. Thanks to the rapid improvement of the electron microscopic techniques and with the advent of aberration corrected electron microscopy as well as theoretical methodologies, the potential effects induced by nanocatalysts are better understood than before by unravelling their atomic structure. A brief introduction to advanced electron microscopic techniques namely aberration corrected scanning transmission electron microscopy (Cs-STEM) is presented and subsequently two examples of nanocatalysts are considered in the present review. The first example will focus on the study of bimetallic/core-shell nanoalloys. In heterogeneous catalysis, catalysts containing two or more metals might show significantly different catalytic properties compared to the parent metals and thus are widely utilized in several catalytic reactions. Atom-by-atom insights of the nanoalloy based catalysts ex: Au-Pd will be described in the present review using a combination of advanced electron microscopic and spectroscopic techniques. A related example on the understanding of bimetallic clusters by HAADF-STEM will also be presented in addition to nanoparticles. In the second case understanding the structure of transition metal chalcogenide based nanocatalysts by HRTEM and aberration corrected STEM, for the case of MoS2 will be discussed. MoS2-based catalysts serve as model catalysts and are employed in the hydrodesulphurisations (HDS) reactions in the removal of sulphur from gasoline and related petrochemical products. They have been studied in various forms including nanowires, nanotubes and nanoplates. Their structure, atomic insights and as a consequence elucidation of their corresponding catalytic activity are thus important.

  13. Low-energy electron transmission through high aspect ratio Al O nanocapillaries

    DEFF Research Database (Denmark)

    Milosavljević, A.R.; Jureta, J.; Víkor, G.;

    2009-01-01

    Electron transmission through insulating AlO nanocapillaries of different diameters (40 and 270 nm) and 15 μm length has been investigated for low-energy electrons (2-120 V). The total intensity of transmitted current weakly depends on the incident electron energy and tilt angle defined with resp......Electron transmission through insulating AlO nanocapillaries of different diameters (40 and 270 nm) and 15 μm length has been investigated for low-energy electrons (2-120 V). The total intensity of transmitted current weakly depends on the incident electron energy and tilt angle defined...

  14. Transmission electron microscopy and time resolved optical spectroscopy study of the electronic and structural interactions of ZnO nanorods with bovine serum albumin.

    Science.gov (United States)

    Klaumünzer, M; Weichsel, U; Mačković, M; Spiecker, E; Peukert, W; Kryschi, C

    2013-08-22

    The adsorption behavior and electronic interactions of bovine serum albumin (BSA) with ZnO nanorod surfaces were investigated using high-resolution transmission electron microscopy as well as stationary and time-resolved optical spectroscopy techniques. Transmission electron microscopy shows that ZnO nanorod surfaces are surrounded by a homogeneous amorphous BSA film with thicknesses between ~2.5 and 5.0 nm. The electronic structure and adsorption geometry of BSA were examined using high-angle annular dark field scanning transmission electron microscopy combined with electron energy loss spectroscopy. The adsorption process was observed to result into an unfolded conformation of BSA becoming predominantly bound in the side-on orientation at the ZnO surface. This adsorption mode of the BSA molecules allows for a strong interaction with surface states of the ZnO nanorods. This is obvious from its efficient quenching of the defect-center photoluminescence of ZnO. Complementary information of electronic interactions across the ZnO nanorod interface was obtained from femtosecond transient absorption spectroscopy experiments. The rise dynamics of the measured transients revealed altered hole trapping dynamics and, thus, indicated to heterogeneous charge transfer as emerging from adsorbed BSA molecules to defect centers of the ZnO interface.

  15. Reliable and robust transmission and storage techniques for medical images with patient information.

    Science.gov (United States)

    Nergui, Myagmarbayar; Acharya, U Sripati; Acharya U, Rajendra; Yu, Wenwei

    2010-12-01

    There is an increased emphasis on the use of digital techniques in all aspects of human life today. Broadcast radio and television, cellular phone services, consumer and entertainment electronics etc are increasingly using digital signal processing techniques to improve the quality of service. Transmission and storage of documentation and images pertaining to patient records cannot remain an exception to this global trend. Hence, patient records (text and image information) are increasingly stored and processed in digital form. Currently, text and image information, which constitute two separate pieces of data are handled as different files. Thus, there is a possibility of the text and message information, pertaining to different patients, being interchanged and thus mishandled. This can be avoided by merging text and image information in such a manner that the two can be separated without perceptible damage to information contained in either file. Digital watermarking techniques can be used to interleave patient information with medical images. In this work, we have employed digital watermarking along with strong cryptographic protocols and powerful error correcting codes. This reduces the probability of sensitive patient information falling into the wrong hands and ensures information integrity when it is conveyed over noisy channels.

  16. Wireless Secured Data Transmission using Cryptographic Techniques through FPGA

    Directory of Open Access Journals (Sweden)

    I.Rama Satya Nageswara Rao

    2016-02-01

    Full Text Available The need to protect the data disturbances and unauthorized access in communication has led to development of several cryptographic algorithms. Current issue in modern world as popularity of internet, e-commerce and communication technologies has emerging and they became the medium to security threats. Due to advancement in cryptographic techniques the DNA technique is a new crypto algorithm to encrypt and decrypt data. It consists of two stage encryption based on DNA sequence enhances the data security compared to conventional methods. In encryption process the former stage will encrypt the data (plain text with a random key generated by random DNA sequence generator. Latter and final stage the encrypted data is re-encrypted with DNA translation to generate cipher. The cryptographic techniques (symmetric algorithm is designed and simulated using Xilinx ISE and targeted on Spartan-3E FPGA interfaced with ZigBee for wireless communication.

  17. Cryogenic transmission electron microscopy nanostructural study of shed microparticles.

    Directory of Open Access Journals (Sweden)

    Liron Issman

    Full Text Available Microparticles (MPs are sub-micron membrane vesicles (100-1000 nm shed from normal and pathologic cells due to stimulation or apoptosis. MPs can be found in the peripheral blood circulation of healthy individuals, whereas elevated concentrations are found in pregnancy and in a variety of diseases. Also, MPs participate in physiological processes, e.g., coagulation, inflammation, and angiogenesis. Since their clinical properties are important, we have developed a new methodology based on nano-imaging that provides significant new data on MPs nanostructure, their composition and function. We are among the first to characterize by direct-imaging cryogenic transmitting electron microscopy (cryo-TEM the near-to-native nanostructure of MP systems isolated from different cell types and stimulation procedures. We found that there are no major differences between the MP systems we have studied, as most particles were spherical, with diameters from 200 to 400 nm. However, each MP population is very heterogeneous, showing diverse morphologies. We investigated by cryo-TEM the effects of standard techniques used to isolate and store MPs, and found that either high-g centrifugation of MPs for isolation purposes, or slow freezing to -80 °C for storage introduce morphological artifacts, which can influence MP nanostructure, and thus affect the efficiency of these particles as future diagnostic tools.

  18. Breaking the spherical and chromatic aberration barrier in transmission electron microscopy.

    Science.gov (United States)

    Freitag, B; Kujawa, S; Mul, P M; Ringnalda, J; Tiemeijer, P C

    2005-02-01

    Since the invention of transmission electron microscopy (TEM) in 1932 (Z. Physik 78 (1932) 318) engineering improvements have advanced system resolutions to levels that are now limited only by the two fundamental aberrations of electron lenses; spherical and chromatic aberration (Z. Phys. 101 (1936) 593). Since both aberrations scale with the dimensions of the lens, research resolution requirements are pushing the designs to lenses with only a few mm space in the pole-piece gap for the specimen. This is in conflict with the demand for more and more space at the specimen, necessary in order to enable novel techniques in TEM, such as He-cooled cryo electron microscopy, 3D-reconstruction through tomography (Science 302 (2003) 1396) TEM in gaseous environments, or in situ experiments (Nature 427 (2004) 426). All these techniques will only be able to achieve Angstrom resolution when the aberration barriers have been overcome. The spherical aberration barrier has recently been broken by introducing spherical aberration correctors (Nature 392 (1998) 392, 418 (2002) 617), but the correction of the remaining chromatic aberrations have proved to be too difficult for the present state of technology (Optik 57 (1980) 73). Here we present an alternative and successful method to eliminate the chromatic blur, which consists of monochromating the TEM beam (Inst. Phys. Conf. Ser. 161 (1999) 191). We show directly interpretable resolutions well below 1A for the first time, which is significantly better than any TEM operating at 200 KV has reached before.

  19. Imaging protein structure in water at 2.7 nm resolution by transmission electron microscopy.

    Science.gov (United States)

    Mirsaidov, Utkur M; Zheng, Haimei; Casana, Yosune; Matsudaira, Paul

    2012-02-22

    We demonstrate an in situ transmission electron microscopy technique for imaging proteins in liquid water at room temperature. Liquid samples are loaded into a microfabricated environmental cell that isolates the sample from the vacuum with thin silicon nitride windows. We show that electron micrographs of acrosomal bundles in water are similar to bundles imaged in ice, and we determined the resolution to be at least 2.7 nm at doses of ∼35 e/Å(2). The resolution was limited by the thickness of the window and radiation damage. Surprisingly, we observed a smaller fall-off in the intensity of reflections in room-temperature water than in 98 K ice. Thus, our technique extends imaging of unstained and unlabeled macromolecular assemblies in water from the resolution of the light microscope to the nanometer resolution of the electron microscope. Our results suggest that real-time imaging of protein dynamics is conceptually feasible. Copyright © 2012 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  20. Transmission electron microscopy of bulk specimens over 10 µm in thickness

    Energy Technology Data Exchange (ETDEWEB)

    Sadamatsu, Sunao, E-mail: sadamatsu@mech.kagoshima-u.ac.jp [Department of Mechanical Engineering, Kagoshima University, Korimoto, Kagoshima 890-0065 (Japan); Tanaka, Masaki; Higashida, Kenji [Department of Materials Science and Engineering, Kyushu University, Nishi-ku, Fukuoka 819-0395 (Japan); Matsumura, Syo [Department of Applied Quantum Physics and Nuclear Engineering, Kyushu University, Nishi-ku, Fukuoka 819-0395 (Japan); Ultramicroscopy Research Center, Kyushu University, Nishi-ku, Fukuoka 819-0395 (Japan)

    2016-03-15

    We succeeded the observation of microstructures in bulk-sized specimens of over 10 µm in thickness by employing a technique that combines transmission electron microscopy (TEM) with energy-filtered imaging based on electron energy-loss spectroscopy (EELS). This method is unique in that it incorporates the inelastically scattered electrons into the imaging process. Using this technique, bright and sharp images of dislocations in crystalline silicon specimens as thick as 10 µm were obtained. A calibration curve to determine foil thickness of such a thick specimen was also derived. This method simply extends the observable thickness range in TEM. If combined with tilt series of observation over a significant range of angle, it will disclose three dimensional nanostructures in a µm-order block of a specimen, promoting our understanding of the controlling mechanisms behind various bulky material properties. - Highlights: • We developed a method which enables thick specimens to be observed using EF-TEM. • The effects of energy filter width and position on images were determined. • We suggested a method to determine the thickness of a thick film sample. • We achieved observation of microstructures in specimens with a thickness of 10 µm.

  1. Nanoscale imaging of whole cells using a liquid enclosure and a scanning transmission electron microscope.

    Directory of Open Access Journals (Sweden)

    Diana B Peckys

    Full Text Available Nanoscale imaging techniques are needed to investigate cellular function at the level of individual proteins and to study the interaction of nanomaterials with biological systems. We imaged whole fixed cells in liquid state with a scanning transmission electron microscope (STEM using a micrometer-sized liquid enclosure with electron transparent windows providing a wet specimen environment. Wet-STEM images were obtained of fixed E. coli bacteria labeled with gold nanoparticles attached to surface membrane proteins. Mammalian cells (COS7 were incubated with gold-tagged epidermal growth factor and fixed. STEM imaging of these cells resulted in a resolution of 3 nm for the gold nanoparticles. The wet-STEM method has several advantages over conventional imaging techniques. Most important is the capability to image whole fixed cells in a wet environment with nanometer resolution, which can be used, e.g., to map individual protein distributions in/on whole cells. The sample preparation is compatible with that used for fluorescent microscopy on fixed cells for experiments involving nanoparticles. Thirdly, the system is rather simple and involves only minimal new equipment in an electron microscopy (EM laboratory.

  2. Strain mapping at the nanoscale using precession electron diffraction in transmission electron microscope with off axis camera

    Energy Technology Data Exchange (ETDEWEB)

    Vigouroux, M. P.; Delaye, V.; Bernier, N.; Lafond, D.; Audoit, G.; Bertin, F. [Université Grenoble Alpes, F-38000 Grenoble (France); CEA, LETI, MINATEC Campus, 17 rue des martyrs, 38054 GRENOBLE Cedex 9 (France); Cipro, R.; Baron, T.; Martin, M. [Université Grenoble Alpes, F-38000 Grenoble (France); CNRS, LTM, F-38000 Grenoble (France); Rouvière, J. L. [Université Grenoble Alpes, F-38000 Grenoble (France); CEA, INAC, MINATEC Campus, 17 rue des martyrs, 38054 GRENOBLE Cedex 9 (France); Chenevier, B. [Université Grenoble Alpes, F-38000 Grenoble (France); LMGP, CNRS, 3 parvis Louis Néel, 38016 GRENOBLE Cedex 1 (France)

    2014-11-10

    Precession electron diffraction is an efficient technique to measure strain in nanostructures by precessing the electron beam, while maintaining a few nanometre probe size. Here, we show that an advanced diffraction pattern treatment allows reproducible and precise strain measurements to be obtained using a default 512 × 512 DigiSTAR off-axis camera both in advanced or non-corrected transmission electron microscopes. This treatment consists in both projective geometry correction of diffraction pattern distortions and strain Delaunay triangulation based analysis. Precision in the strain measurement is improved and reached 2.7 × 10{sup −4} with a probe size approaching 4.2 nm in diameter. This method is applied to the study of the strain state in InGaAs quantum-well (QW) devices elaborated on Si substrate. Results show that the GaAs/Si mismatch does not induce in-plane strain fluctuations in the InGaAs QW region.

  3. Transmission electron microscopy of unstained hybrid Au nanoparticles capped with PPAA (plasma-poly-allylamine): structure and electron irradiation effects.

    Science.gov (United States)

    Gontard, Lionel C; Fernández, Asunción; Dunin-Borkowski, Rafal E; Kasama, Takeshi; Lozano-Pérez, Sergio; Lucas, Stéphane

    2014-12-01

    Hybrid (organic shell-inorganic core) nanoparticles have important applications in nanomedicine. Although the inorganic components of hybrid nanoparticles can be characterized readily using conventional transmission electron microscopy (TEM) techniques, the structural and chemical arrangement of the organic molecular components remains largely unknown. Here, we apply TEM to the physico-chemical characterization of Au nanoparticles that are coated with plasma-polymerized-allylamine, an organic compound with the formula C3H5NH2. We discuss the use of energy-filtered TEM in the low-energy-loss range as a contrast enhancement mechanism for imaging the organic shells of such particles. We also study electron-beam-induced crystallization and amorphization of the shells and the formation of graphitic-like layers that contain both C and N. The resistance of the samples to irradiation by high-energy electrons, which is relevant for optical tuning and for understanding the degree to which such hybrid nanostructures are stable in the presence of biomedical radiation, is also discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Unravelling surface and interfacial structures of a metal–organic framework by transmission electron microscopy

    KAUST Repository

    Zhu, Yihan

    2017-02-21

    Metal–organic frameworks (MOFs) are crystalline porous materials with designable topology, porosity and functionality, having promising applications in gas storage and separation, ion conduction and catalysis1, 2, 3. It is challenging to observe MOFs with transmission electron microscopy (TEM) due to the extreme instability of MOFs upon electron beam irradiation4, 5, 6, 7. Here, we use a direct-detection electron-counting camera to acquire TEM images of the MOF ZIF-8 with an ultralow dose of 4.1 electrons per square ångström to retain the structural integrity. The obtained image involves structural information transferred up to 2.1 Å, allowing the resolution of individual atomic columns of Zn and organic linkers in the framework. Furthermore, TEM reveals important local structural features of ZIF-8 crystals that cannot be identified by diffraction techniques, including armchair-type surface terminations and coherent interfaces between assembled crystals. These observations allow us to understand how ZIF-8 crystals self-assemble and the subsequent influence of interfacial cavities on mass transport of guest molecules.

  5. Coherent, non-planar illumination of a defocused specimen: consequences for transmission electron microscopy

    Science.gov (United States)

    Patwardhan, Ardan

    The objective of this study has been to examine the imaging properties of transmission electron microscopes when coherent non-planar illumination is used in conjunction with defocused specimens. This situation is reminiscent of what is commonly the case in electron microscopic phase-contrast studies of biologically relevant macromolecules, using a field emission gun as a coherent electron source. For the sake of simplicity, the imaging system has been idealized as a thin lens with properties that can be described by the Fresnel approximation of the Huygens-Fresnel principle. The resulting expressions show that the system magnification has a defocus dependent factor, as do the contrast transfer functions. These factors are normally not taken into account in conventional derivations. The defocus dependent factor can be minimized by using planar illumination. The factor approaches infinity as the crossover moves closer to the specimen, and it is in the region close to the specimen that this factor is most significant. These results can have serious implications for high-resolution single-particle cryo electron microscopy as this technique often relies on combining data taken at a range of defocus values.

  6. A Quantitative Nanodiffraction System for Ultrahigh Vacuum Scanning Transmission Electron Microscopy

    Science.gov (United States)

    Hembree, Gary G.; Koch, Christoph; Spence, John C. H.

    2003-10-01

    Of all the long-lived particles available as probes of condensed matter, and of all the signals available on a modern electron microscope, electron nanodiffraction patterns provide the strongest signal from the smallest volume. The technique is therefore perfectly suited to nanostructural investigations in inorganic chemistry and materials science. The Vacuum Generators HB501S, an ultrahigh vacuum (UHV) variant of the HB501 scanning transmission electron microscope (STEM), with side-entry double-tilt stage, specimen preparation and analysis chamber, three postspecimen lenses, and cold field-emission tip with integral magnetic gun lens, has therefore been modified to optimize nanodiffraction and quantitative convergent beam electron diffraction (QCBED) performance. A one-micrometer grain-size phosphor screen lying on a fiber-optic faceplate atop the instrument is fiber-optically coupled to a 2048 × 2048 charge-coupled device (CCD), 16-bit camera. This arrangement promises to provide much greater sensitivity, larger dynamic range, and a better modulation transfer function (MTF) than conventional single crystal scintillator (YAG) CCD systems, with noticeable absence of cross talk between pixels. The design of the nanodiffraction detector system is discussed, the gain of the detector is measured, the spherical aberration constant of the objective lens is measured by the Ronchigram method, and preliminary results from the modified instrument are shown.

  7. Unravelling surface and interfacial structures of a metal-organic framework by transmission electron microscopy

    Science.gov (United States)

    Zhu, Yihan; Ciston, Jim; Zheng, Bin; Miao, Xiaohe; Czarnik, Cory; Pan, Yichang; Sougrat, Rachid; Lai, Zhiping; Hsiung, Chia-En; Yao, Kexin; Pinnau, Ingo; Pan, Ming; Han, Yu

    2017-05-01

    Metal-organic frameworks (MOFs) are crystalline porous materials with designable topology, porosity and functionality, having promising applications in gas storage and separation, ion conduction and catalysis. It is challenging to observe MOFs with transmission electron microscopy (TEM) due to the extreme instability of MOFs upon electron beam irradiation. Here, we use a direct-detection electron-counting camera to acquire TEM images of the MOF ZIF-8 with an ultralow dose of 4.1 electrons per square ångström to retain the structural integrity. The obtained image involves structural information transferred up to 2.1 Å, allowing the resolution of individual atomic columns of Zn and organic linkers in the framework. Furthermore, TEM reveals important local structural features of ZIF-8 crystals that cannot be identified by diffraction techniques, including armchair-type surface terminations and coherent interfaces between assembled crystals. These observations allow us to understand how ZIF-8 crystals self-assemble and the subsequent influence of interfacial cavities on mass transport of guest molecules.

  8. Rapidly Alternating Transmission Mode Electron Transfer Dissociation and Collisional Activation for the Characterization of Polypeptide Ions

    Science.gov (United States)

    Han, Hongling; Xia, Yu; Yang, Min; McLuckey, Scott A.

    2009-01-01

    Cation transmission/electron transfer reagent anion storage mode electron transfer ion/ion reactions and beam-type collisional activation of the polypeptide ions are performed in rapid succession in the high pressure collision cell (Q2) of a quadrupole/time-of-flight tandem mass spectrometer (QqTOF), where the electron transfer reagent anions are accumulated. Duty cycles for both electron transfer dissociation (ETD) and collision-induced dissociation (CID) experiments are improved relative to ion trapping approaches since there are no discrete ion storage and reaction steps for ETD experiments and no discrete ion storage step and frequency tuning for CID experiments. For this technique, moderately high resolution and mass accuracy are also obtained due to mass analysis via the TOF analyzer. This relatively simple approach has been demonstrated with a triply charged tryptic peptide, a triply charged tryptic phosphopeptide, and a triply charged tryptic N-linked glycopeptide. For the tryptic peptide, the sequence is identified with more certainty than would be available from a single method alone due to the complementary information provided by these two dissociation methods. Because of the complementary information derived from both ETD and CID dissociation methods, peptide sequence and post-translational modification (PTM) sites for the phosphopeptide are identified. This combined ETD and CID approach is particularly useful for characterizing glycopeptides because ETD generates information about both peptide sequence and locations of the glycosylation sites while CID provides information about the glycan structure. PMID:18396915

  9. Practical spatial resolution of electron energy loss spectroscopy in aberration corrected scanning transmission electron microscopy.

    Science.gov (United States)

    Shah, A B; Ramasse, Q M; Wen, J G; Bhattacharya, A; Zuo, J M

    2011-08-01

    The resolution of electron energy loss spectroscopy (EELS) is limited by delocalization of inelastic electron scattering rather than probe size in an aberration corrected scanning transmission electron microscope (STEM). In this study, we present an experimental quantification of EELS spatial resolution using chemically modulated 2×(LaMnO(3))/2×(SrTiO(3)) and 2×(SrVO(3))/2×(SrTiO(3)) superlattices by measuring the full width at half maxima (FWHM) of integrated Ti M(2,3), Ti L(2,3), V L(2,3), Mn L(2,3), La N(4,5), La N(2,3) La M(4,5) and Sr L(3) edges over the superlattices. The EELS signals recorded using large collection angles are peaked at atomic columns. The FWHM of the EELS profile, obtained by curve-fitting, reveals a systematic trend with the energy loss for the Ti, V, and Mn edges. However, the experimental FWHM of the Sr and La edges deviates significantly from the observed experimental tendency.

  10. Resolution enhancement in transmission electron microscopy with 60-kV monochromated electron source

    Energy Technology Data Exchange (ETDEWEB)

    Morishita, Shigeyuki; Mukai, Masaki; Sawada, Hidetaka [JEOL Ltd., 3-1-2 Musashino, Akishima, Tokyo 196-8558 (Japan); Suenaga, Kazutomo [National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Higashi, Tsukuba, Ibaraki 305-8565 (Japan)

    2016-01-04

    Transmission electron microscopy (TEM) at low accelerating voltages is useful to obtain images with low irradiation damage. For a low accelerating voltage, linear information transfer, which determines the resolution for observation of single-layered materials, is largely limited by defocus spread, which improves when a narrow energy spread is used in the electron source. In this study, we have evaluated the resolution of images obtained at 60 kV by TEM performed with a monochromated electron source. The defocus spread has been evaluated by comparing diffractogram tableaux from TEM images obtained under nonmonochromated and monochromated illumination. The information limits for different energy spreads were precisely measured by using diffractograms with a large beam tilt. The result shows that the information limit reaches 0.1 nm with an energy width of 0.10 eV. With this monochromated source and a higher-order aberration corrector, we have obtained images of single carbon atoms in a graphene sheet by TEM at 60 kV.

  11. Nicotiana Occidentalis Chloroplast Ultrastructure imaged with Transmission Electron Microscopes Working at Different Accelerating Voltages

    OpenAIRE

    SVIDENSKÁ, Silvie

    2010-01-01

    The main goal of this thesis is to study and compare electron microscopy images of Nicotiana Occidentalis chloroplasts, obtained from two types of transmission electron microscopes,which work with different accelerating voltage of 80kV and 5kV. The two instruments, TEM JEOL 1010 and low voltage electron microscope LVEM5 are employed for experiments. In the first theoretical part, principle of electron microscopy and chloroplast morphology is described. In experimental part, electron microscop...

  12. In-situ reduction of promoted cobalt oxide supported on alumina by environmental transmission electron microscopy

    DEFF Research Database (Denmark)

    Dehghan, Roya; Hansen, Thomas Willum; Wagner, Jakob Birkedal

    2011-01-01

    Reduction of 12wt.%Co/0.5wt.%Re/α-Al2O3 Fischer–Tropsch catalyst has been studied in-situ in an environmental transmission electron microscope. Reduction of Co3O4 to metallic cobalt was observed dynamically at 360 °C under 3.4 mbar H2. Structural and morphological changes were observed by high...... resolution transmission electron microscopy and scanning transmission electron microscopy imaging. The cobalt particles were mainly face centred cubic while some hexagonal close packed particles were also found. Reoxidation of the sample upon cooling to room temperature, still under flowing H2, underlines...

  13. 21 CFR 1311.05 - Standards for technologies for electronic transmission of orders.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 9 2010-04-01 2010-04-01 false Standards for technologies for electronic... JUSTICE REQUIREMENTS FOR ELECTRONIC ORDERS AND PRESCRIPTIONS (Eff. 6-1-10) General § 1311.05 Standards for technologies for electronic transmission of orders. (a) A registrant or a person with power of attorney to...

  14. Electronic test instrumentation and techniques: A compilation

    Science.gov (United States)

    1974-01-01

    The uses of test equipment and techniques used in space research and development programs are discussed. Modifications and adaptations to enlarge the scope of usefulness or divert the basic uses to alternate applications are analyzed. The items of equipment which have been of benefit to professional personnel in the enlargement and improvement of quality control capabilities are identified. Items which have been simplified or made more accurate in conducting measurements are described.

  15. Optimal experimental design for the detection of light atoms from high-resolution scanning transmission electron microscopy images

    OpenAIRE

    Gonnissen, J.; De Backer, A.; Den Dekker, A.J.; Martinez, G. T.; Rosenauer, A.; Sijbers, J.; Van Aert, S.

    2014-01-01

    Abstract: We report an innovative method to explore the optimal experimental settings to detect light atoms from scanning transmission electron microscopy (STEM) images. Since light elements play a key role in many technologically important materials, such as lithium-battery devices or hydrogen storage applications, much effort has been made to optimize the STEM technique in order to detect light elements. Therefore, classical performance criteria, such as contrast or signal-to-noise ratio, a...

  16. Electronic transmission and switch effect in kappa-component Fibonacci nanowires.

    Science.gov (United States)

    Li, Jia; Zhang, Ruili; Li, De; Peng, Ruwen; Wang, Mu

    2010-11-01

    We present the electronic transport in the k-component Fibonacci (KCF) nanowires, in which kappa different incommensurate intervals are arranged according to a substitution rule. For the KCF nanowires with an identical kappa, by increasing the length of the nanowire, the minima in transmission extend gradually into the band gap over which the transmission is blocked. Meanwhile more transmission peaks appear. For finite KCF nanowire, by increasing the number of different incommensurate intervals kappa, the width of electronic band gap is enlarged. Moreover, when the value of kappa is sufficiently large, the transmission is shut off, except at a few resonant energies. These properties make it possible to use the KCF nanowires as switching devices. Furthermore, a dimensional spectrum of singularities associated with the transmission spectrum demonstrates that the electronic propagation in the KCF nanowire shows multifractality. These investigations open a unique way to control quantum transport in nanodevices.

  17. A Data Transmission Technique for Personal Health Systems

    Directory of Open Access Journals (Sweden)

    Jih-Fu Tu

    2013-01-01

    Full Text Available We used the modular technique to design a personal health data transmitter (PHDT that is composed of the following components: (1 the core is an embedded signal chip, (2 three kinds of transmutation modules such as USB, RF, and UART, (3 an I2C interface is used to acquire the users data, and (4 through Internet it links to the cloud server to store the personal-health data. By the experiment, we find that the modular manner is feasible, stable of functional, integral, and accurate, while it is exploited to design the PHDT. For the experiment, we present each module algorithm to find that our system is very helpful to people.

  18. Microstructural characterization of Ni-22Fe-22Cr-6Al metallic foam by transmission electron microscopy.

    Science.gov (United States)

    Kim, Hyung Giun; Lee, Taeg Woo; Lee, Jae Young; Lee, Eui Sung; Oh, Kwon Oh; Lee, Chang Woo; Lim, Sung Hwan

    2012-01-01

    Ni-22Fe-22Cr-6Al metallic foam, prepared using a thermomechanical treatment and alloying elements, was studied via transmission electron microscopy (TEM) in order to clarify the relationship between the mechanical properties and the nanoscale microstructural characteristics. Due to the unique porous structure of the metallic foam, TEM specimens were prepared using an embedding-process-assisted-ion-milling technique and a focused-ion-beam method. The Cr-, Fe- and Al-clustered regions around the surface of the metallic foam were investigated using elemental maps. The Ni(3)Al (γ') precipitates, which can affect the mechanical properties of the Ni-Fe-Cr (γ) matrix, were characterized in the metallic foam.

  19. Preparation of cross-sectional specimens of ceramic thermal barrier coatings for transmission electron microscopy.

    Science.gov (United States)

    Unal, O; Heuer, A H; Mitchell, T E

    1990-04-01

    During the microstructural examination of ceramic thermal barrier coatings by transmission electron microscopy (TEM), initial efforts for the preparation of cross-sectional thin foils from interface regions by conventional means were mostly failures. Delamination of the Y2O3-stabilized ZrO2 ceramic coating from the nickel-base alloy substrate sometimes occurred during fine polishing at around 80 microns thickness but mostly occurred during dimpling. Because of this sensitivity, special techniques for mechanical handling were developed so that ion milling could give thin enough regions of the metal-ceramic interface. TEM showed convincingly that the highly fragile nature of the coatings is in fact due to the extensive porosity at the interface developed as a result of heat treatment.

  20. Microtubules in Plant Cells: Strategies and Methods for Immunofluorescence, Transmission Electron Microscopy and Live Cell Imaging

    Science.gov (United States)

    Celler, Katherine; Fujita, Miki; Kawamura, Eiko; Ambrose, Chris; Herburger, Klaus; Wasteneys, Geoffrey O.

    2016-01-01

    Microtubules are required throughout plant development for a wide variety of processes, and different strategies have evolved to visualize and analyze them. This chapter provides specific methods that can be used to analyze microtubule organization and dynamic properties in plant systems and summarizes the advantages and limitations for each technique. We outline basic methods for preparing samples for immunofluorescence labelling, including an enzyme-based permeabilization method, and a freeze-shattering method, which generates microfractures in the cell wall to provide antibodies access to cells in cuticle-laden aerial organs such as leaves. We discuss current options for live cell imaging of MTs with fluorescently tagged proteins (FPs), and provide chemical fixation, high pressure freezing/freeze substitution, and post-fixation staining protocols for preserving MTs for transmission electron microscopy and tomography. PMID:26498784

  1. Grids for Applications in High-Temperature High-Resolution Transmission Electron Microscopy

    Directory of Open Access Journals (Sweden)

    Yucheng Lan

    2010-01-01

    Full Text Available New TEM grids coated with ultrathin amorphous Al2O3 films have been developed using atomic layer deposition technique. The amorphous Al2O3 films can withstand temperatures over 600∘C in air and 900∘C in vacuum when the thickness of the Al2O3 film is 2 nm, and up to 1000∘C in air when the thickness is 25 nm, which makes heating TEM grids with nanoparticles up to 1000∘C in air and immediate TEM observation without interrupting the nanoparticles possible. Such coated TEM grids are very much desired for applications in high-temperature high-resolution transmission electron microscopy.

  2. Advanced thermal management techniques for space power electronics

    Science.gov (United States)

    Reyes, Angel Samuel

    1992-01-01

    Modern electronic systems used in space must be reliable and efficient with thermal management unaffected by outer space constraints. Current thermal management techniques are not sufficient for the increasing waste heat dissipation of novel electronic technologies. Many advanced thermal management techniques have been developed in recent years that have application in high power electronic systems. The benefits and limitations of emerging cooling technologies are discussed. These technologies include: liquid pumped devices, mechanically pumped two-phase cooling, capillary pumped evaporative cooling, and thermoelectric devices. Currently, liquid pumped devices offer the most promising alternative for electronics thermal control.

  3. Bio and nano packaging techniques for electron devices advances in electronic device packaging

    CERN Document Server

    Gerlach, Gerald

    2014-01-01

    This book offers an overview of nanoscale components and systems comprising electronic, mechanical and optical structures, describes trends and developments in electron device packaging, and discusses application of nano and bio techniques in future solutions.

  4. In situ transmission electron microscopy of light-induced photocatalytic reactions

    DEFF Research Database (Denmark)

    Cavalca, Filippo; Laursen, Anders Bo; Kardynal, Beata

    2012-01-01

    Transmission electron microscopy (TEM) makes it possible to obtain insight into the structure, composition and reactivity of photocatalysts, which are of fundamental interest for sustainable energy research. Such insight can be used for further material optimization. Here, we combine conventional...

  5. TISSUE INTERACTIONS WITH DERMAL SHEEP COLLAGEN IMPLANTS - A TRANSMISSION ELECTRON-MICROSCOPIC EVALUATION

    NARCIS (Netherlands)

    VANWACHEM, PB; VANLUYN, MJA; DAMINK, LO; FEIJEN, J; NIEUWENHUIS, P

    1991-01-01

    Tissue interactions with discs of dermal sheep collagen (DSC), subcutaneously implanted in rats, were evaluated using transmission electron microscopy. DSC cross-linked with hexamethylenediisocyanate (HDSC) had already been tested previously. In the present study, we compared tissue interactions of

  6. Automated magnification calibration in transmission electron microscopy using Fourier analysis of replica images.

    NARCIS (Netherlands)

    Laak, J.A.W.M. van der; Dijkman, H.B.P.M.; Pahlplatz, M.M.M.

    2006-01-01

    The magnification factor in transmission electron microscopy is not very precise, hampering for instance quantitative analysis of specimens. Calibration of the magnification is usually performed interactively using replica specimens, containing line or grating patterns with known spacing. In the pre

  7. Advanced scanning transmission stereo electron microscopy of structural and functional engineering materials

    Energy Technology Data Exchange (ETDEWEB)

    Agudo Jacome, L., E-mail: leonardo.agudo@bam.de [Institut fuer Werkstoffe, Ruhr-Universitaet Bochum, D-44780 Bochum (Germany); Eggeler, G., E-mail: gunther.eggeler@ruhr-uni-bochum.de [Institut fuer Werkstoffe, Ruhr-Universitaet Bochum, D-44780 Bochum (Germany); Dlouhy, A., E-mail: dlouhy@ipm.cz [Institute of Physics of Materials, Academy of Sciences of the Czech Republic, Zizkova 22, 616 62 Brno (Czech Republic)

    2012-11-15

    Stereo transmission electron microscopy (TEM) provides a 3D impression of the microstructure in a thin TEM foil. It allows to perform depth and TEM foil thickness measurements and to decide whether a microstructural feature lies inside of a thin foil or on its surface. It allows appreciating the true three-dimensional nature of dislocation configurations. In the present study we first review some basic elements of classical stereo TEM. We then show how the method can be extended by working in the scanning transmission electron microscope (STEM) mode of a modern analytical 200 kV TEM equipped with a field emission gun (FEG TEM) and a high angle annular dark field (HAADF) detector. We combine two micrographs of a stereo pair into one anaglyph. When viewed with special colored glasses the anaglyph provides a direct and realistic 3D impression of the microstructure. Three examples are provided which demonstrate the potential of this extended stereo TEM technique: a single crystal Ni-base superalloy, a 9% Chromium tempered martensite ferritic steel and a NiTi shape memory alloy. We consider the effect of camera length, show how foil thicknesses can be measured, and discuss the depth of focus and surface effects. -- Highlights: Black-Right-Pointing-Pointer The advanced STEM/HAADF diffraction contrast is extended to 3D stereo-imaging. Black-Right-Pointing-Pointer The advantages of the new technique over stereo-imaging in CTEM are demonstrated. Black-Right-Pointing-Pointer The new method allows foil thickness measurements in a broad range of conditions. Black-Right-Pointing-Pointer We show that features associated with ion milling surface damage can be beneficial for appreciating 3D features of the microstructure.

  8. Catalysts under Controlled Atmospheres in the Transmission Electron Microscope

    DEFF Research Database (Denmark)

    Hansen, Thomas Willum; Wagner, Jakob Birkedal

    2014-01-01

    microscope, and since its invention by Ernst Ruska, the idea of imaging samples under gaseous atmospheres was envisioned. However, microscopes have traditionally been operated in high vacuum due to sensitive electron sources, sample contamination, and electron scattering off gas molecules resulting in loss...

  9. Ultra-precise measurement of optical aberrations for sub-Aangstroem transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Barthel, J.

    2008-06-15

    Quantitative investigations of material structures on an atomic scale by means of highresolution transmission electron microscopy (HRTEM) impose not only extreme demands on the mechanic and electromagnetic stability of the applied instruments but require also their precise electron-optical adjustment. Today a physical resolution well below one Aangstroem can be achieved with commercially available microscopes on a daily basis. However, the achieved resolution can often not be reliably exploited for the interpretation of the resulting microscopical data due to the presence of so-called higher-order lens aberrations. At the starting time of this work, a sufficiently accurate procedure to measure higher-order aberrations was urgently missing. Since aberration measurement is a mandatory prerequisite for any technique of aberration control enabling quantitative high-resolution microscopy, the goal of this work is to develop such a measurement procedure for the Sub-Aangstroem regime. The measurement procedures developed in the course of this work are based on the numerical evaluation of a series of images taken from an amorphous object under electron-beam illumination with varying tilt. New techniques have been developed for the evaluation of single images as well as for the optimised evaluation of the whole series. These procedures allow microscope users to perform quantitative HRTEM even at a resolution of 0.5 Aangstroem. The precision reached with the newly developed measurement procedures is unprecedented and surpasses existing solutions by at least one order of magnitude in any respect. All the concepts and procedures for aberration measurement developed in this work have been implemented in a software package which satisfies professional demands with respect to robustness, precision, speed and user-friendliness. The new automatic aberrationmeasurement procedures are suitable to establish HRTEM as a quantitative technique for material science investigations in the

  10. Aberration corrected and monochromated environmental transmission electron microscopy: challenges and prospects for materials science

    DEFF Research Database (Denmark)

    Hansen, Thomas Willum; Wagner, Jakob Birkedal; Dunin-Borkowski, Rafal E.

    2010-01-01

    The latest generation of environmental transmission electron microscopes incorporates aberration correctors and monochromators, allowing studies of chemical reactions and growth processes with improved spatial resolution and spectral sensitivity. Here, we describe the performance of such an instr......The latest generation of environmental transmission electron microscopes incorporates aberration correctors and monochromators, allowing studies of chemical reactions and growth processes with improved spatial resolution and spectral sensitivity. Here, we describe the performance...

  11. THz-field-induced electronic transmission step-structure for a quantum wire

    Institute of Scientific and Technical Information of China (English)

    Xiao Xian-Bo; Zhou Guang-Hui; Yang Mou; Li Yuan; Xu Zhi-Feng

    2004-01-01

    We study theoretically the low-temperature electronic transport property of a straight quantum wire under the irradiation of a finite-range transversely polarized external terahertz (THz) electromagnetic (EM) field. Using the freeelectron model and the scattering matrix approach, we show an unusual behaviour of the electronic transmission of this system. A sharp step-structure appears in the electronic transmission probability as the EM field strength increases to a threshold value when a coherent EM field is applied. We demonstrate that this effect physically comes from the inelastic scattering of electrons with lateral photons through intersubband transitions.

  12. Simultaneous measurement of lateral and vertical size of nanoparticles using transmission scanning electron microscopy (TSEM)

    Science.gov (United States)

    Buhr, E.; Bug, M. U.; Bergmann, D.; Cizmar, P.; Frase, C. G.

    2017-03-01

    A scanning electron microscope operated in transmission mode (TSEM) enables both the measurement of the lateral and vertical size (thickness) of nanoparticles. The lateral size is measured with a previously described technique where the particle boundary is determined in the TSEM image. Particle thickness is deduced from the TSEM signal level measured at the centre of the particle, which requires prior knowledge of the expected TSEM signal level. We applied different and well-known Monte-Carlo based simulation tools (Geant4 and MCSEM) to describe the electron diffusion in solid states and to calculate the expected TSEM signals taking into account particle and instrument properties. The simulation results of the different simulation models differ slightly revealing current limits of small-angle and low-energy electron scattering modelling in solid states. Nonetheless, the method allows one to correlate lateral and vertical particle thickness and thus to obtain additional information about the 3D morphology of nanoparticles. We demonstrate the method for silica particles with sizes in the range of about 10 nm–100 nm.

  13. A technique for pediatric total skin electron irradiation

    OpenAIRE

    Bao Qinan; Hrycushko Brian A; Dugas Joseph P; Hager Frederick H; Solberg Timothy D

    2012-01-01

    Abstract Background Total skin electron irradiation (TSEI) is a special radiotherapy technique which has generally been used for treating adult patients with mycosis fungoides. Recently, two infants presented with leukemia cutis isolated to the skin requiring TSEI. This work discusses the commissioning and quality assurance (QA) methods for implementing a modified Stanford technique using a rotating harness system to position sedated pediatric patients treated with electrons to the total skin...

  14. The effect of different electrodes on the electronic transmission of benzene junctions: Analytical approach

    Energy Technology Data Exchange (ETDEWEB)

    Mohebbi, Razie; Seyed-Yazdi, Jamileh, E-mail: j.seyedyazdi@vru.ac.ir

    2016-06-01

    In this paper we have investigated the electronic transmission of systems electrode–benzene–electrode using the Landauer approach. The effect of different electrodes made of metal (Au) and semiconductors (Si, TiO{sub 2}) is investigated. These three electrodes are compared between them and the results show that the electronic transmission of benzene junctions, when using semiconductor electrodes, is associated to a gap in transmission which is due to the electrodes band gap. As a consequence, a threshold voltage is necessary to obtain conducting channels.

  15. An Interference-Aware Distributed Transmission Technique for Dense Small Cell Networks

    DEFF Research Database (Denmark)

    Mahmood, Nurul Huda; Berardinelli, Gilberto; Pedersen, Klaus I.

    2015-01-01

    transmission technique that can efficiently manage the interference in an uncoordinated dense small cell network is investigated in this work. The proposed interference aware scheme only requires instantaneous channel state information at the transmitter end towards the desired receiver. Motivated by penalty...... methods in optimization studies, an interference dependent weighting factor is introduced to control the number of parallel transmission streams. The proposed scheme can outperform a more complex benchmark transmission scheme in terms of the sum network throughput in certain scenarios and with realistic...

  16. In SITU Transmission Electron Microscopy on Operating Electrochemical CELLS

    DEFF Research Database (Denmark)

    Gualandris, Fabrizio; Simonsen, Søren Bredmose; Mogensen, Mogens Bjerg

    2016-01-01

    Solid oxide cells (SOC) have the potential of playing a significant role in the future efficient energy system scenario. In order to become widely commercially available, an improved performance and durability of the cells has to be achieved [1]. Conventional scanning and transmission SEM and TEM...... have been often used for ex-situ post mortem characterization of SOFCs and SOECs [2,3]. However, in order to get fundamental insight of the microstructural development of SOFC/SOEC during operation conditions in situ studies are necessary [4]....

  17. In SITU Transmission Electron Microscopy on Operating Electrochemical CELLS

    DEFF Research Database (Denmark)

    Gualandris, Fabrizio; Simonsen, Søren Bredmose; Mogensen, Mogens Bjerg

    2016-01-01

    Solid oxide cells (SOC) have the potential of playing a significant role in the future efficient energy system scenario. In order to become widely commercially available, an improved performance and durability of the cells has to be achieved [1]. Conventional scanning and transmission SEM and TEM...... have been often used for ex-situ post mortem characterization of SOFCs and SOECs [2,3]. However, in order to get fundamental insight of the microstructural development of SOFC/SOEC during operation conditions in situ studies are necessary [4]....

  18. High precision ultrasonic guided wave technique for inspection of power transmission line

    Science.gov (United States)

    Cheng, Jun; Qiu, Jinhao; Ji, Hongli; Wang, Enrong; Takagi, Toshiyuki; Uchimoto, Tetsuya

    2017-01-01

    Due to the merits of high inspection speed and long detecting distance, Ultrasonic Guided Wave(UGW) method has been commonly applied to the on-line maintenance of power transmission line. However, the guided wave propagation in this structure is very complicated, leading to the unfavorable defect localization accuracy. Aiming at this situation, a high precision UGW technique for inspection of local surface defect in power transmission line is proposed. The technique is realized by adopting a novel segmental piezoelectric ring transducer and transducer mounting scheme, combining with the comprehensive characterization of wave propagation and circumferential defect positioning with multiple piezoelectric elements. Firstly, the propagation path of guided waves in the multi-wires of transmission line under the proposed technique condition is investigated experimentally. Next, the wave velocities are calculated by dispersion curves and experiment test respectively, and from comparing of the two results, the guided wave mode propagated in transmission line is confirmed to be F(1,1) mode. Finally, the axial and circumferential positioning of local defective wires in transmission line are both achieved, by using multiple piezoelectric elements to surround the stands and send elastic waves into every single wire. The proposed research can play a role of guiding the development of highly effective UGW method and detecting system for multi-wire transmission line.

  19. Imaging Protein Structure in Water at 2.7 nm Resolution by Transmission Electron Microscopy

    Science.gov (United States)

    Mirsaidov, Utkur M.; Zheng, Haimei; Casana, Yosune; Matsudaira, Paul

    2012-01-01

    We demonstrate an in situ transmission electron microscopy technique for imaging proteins in liquid water at room temperature. Liquid samples are loaded into a microfabricated environmental cell that isolates the sample from the vacuum with thin silicon nitride windows. We show that electron micrographs of acrosomal bundles in water are similar to bundles imaged in ice, and we determined the resolution to be at least 2.7 nm at doses of ∼35 e/Å2. The resolution was limited by the thickness of the window and radiation damage. Surprisingly, we observed a smaller fall-off in the intensity of reflections in room-temperature water than in 98 K ice. Thus, our technique extends imaging of unstained and unlabeled macromolecular assemblies in water from the resolution of the light microscope to the nanometer resolution of the electron microscope. Our results suggest that real-time imaging of protein dynamics is conceptually feasible. PMID:22385868

  20. Transmission of Megawatt Relativistic Electron Beams Through Millimeter Apertures

    CERN Document Server

    Alarcon, R; Benson, S V; Bertozzi, W; Boyce, J R; Cowan, R; Douglas, D; Evtushenko, P; Fisher, P; Ihloff, E; Kalantarians, N; Kelleher, A; Legg, R; Milner, R G; Neil, G R; Ou, L; Schmookler, B; Tennant, C; Tschalaer, C; Williams, G P; Zhang, S

    2013-01-01

    High power, relativistic electron beams from energy recovery linacs have great potential to realize new experimental paradigms for pioneering innovation in fundamental and applied research. A major design consideration for this new generation of experimental capabilities is the understanding of the halo associated with these bright, intense beams. In this Letter, we report on measurements performed using the 100 MeV, 430 kWatt CW electron beam from the energy recovery linac at the Jefferson Laboratory's Free Electron Laser facility as it traversed a set of small apertures in a 127 mm long aluminum block. Thermal measurements of the block together with neutron measurements near the beam-target interaction point yielded a consistent understanding of the beam losses. These were determined to be 3 ppm through a 2 mm diameter aperture and were maintained during a 7 hour continuous run.

  1. Possibilities of the mirror through transmission electromagnetic-acoustic technique on multiple reflections

    Science.gov (United States)

    Petrov, K. V.; Muravieva, O. V.; Gabbasova, M. A.; Zorin, V. A.

    2017-08-01

    The approaches to the implementation of the mirror through transmission electromagnetic-acoustic (EMA) testing technique on multiple reflections are introduced. Operating principles of through-type EMA transducers and the special-purpose installation realizing the mirror through transmission EMA testing technique on multiple reflections are described. The modeling results of electrodynamic mechanism of interaction between the through type EMA transducers are presented and used for the efficiency increase and the improvement of dimensional characteristics. The special model, with the use of which the formation principles of through-type EMA transducer acoustic fields in cylindrical objects were investigated, is developed. The additional informative parameters based on the correlation, spectral and probability and statistic analyses of the multiple reflections oscillograms are suggested. The results of structural analysis and investigation of acoustoelasticity with the use of the mirror through transmission EMA technique on the multiple reflections are presented.

  2. Electro-optic techniques in electron beam diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    van Tilborg, Jeroen; Toth, Csaba; Matlis, Nicholas; Plateau, Guillaume; Leemans, Wim

    2011-06-17

    Electron accelerators such as laser wakefield accelerators, linear accelerators driving free electron lasers, or femto-sliced synchrotrons, are capable of producing femtosecond-long electron bunches. Single-shot characterization of the temporal charge profile is crucial for operation, optimization, and application of such accelerators. A variety of electro-optic sampling (EOS) techniques exists for the temporal analysis. In EOS, the field profile from the electron bunch (or the field profile from its coherent radiation) will be transferred onto a laser pulse co-propagating through an electro-optic crystal. This paper will address the most common EOS schemes and will list their advantages and limitations. Strong points that all techniques share are the ultra-short time resolution (tens of femtoseconds) and the single-shot capabilities. Besides introducing the theory behind EOS, data from various research groups is presented for each technique.

  3. Anisotropic Shape Changes of Silica Nanoparticles Induced in Liquid with Scanning Transmission Electron Microscopy

    NARCIS (Netherlands)

    Zecevic, J.; Hermannsdorfer, Justus; Schuh, Tobias; de Jong, Krijn P.; de Jonge, Niels

    2017-01-01

    Liquid-phase transmission electron microscopy (TEM) is used for in-situ imaging of nanoscale processes taking place in liquid, such as the evolution of nanoparticles during synthesis or structural changes of nanomaterials in liquid environment. Here, it is shown that the focused electron beam of

  4. Direct observations of the MOF (UiO-66) structure by transmission electron microscopy

    KAUST Repository

    Zhu, Liangkui

    2013-01-01

    As a demonstration of ab initio structure characterizations of nano metal organic framework (MOF) crystals by high resolution transmission electron microscopy (HRTEM) and electron diffraction tomography methods, a Zr-MOF (UiO-66) structure was determined and further confirmed by Rietveld refinements of powder X-ray diffraction. HRTEM gave direct imaging of the channels. © 2013 The Royal Society of Chemistry.

  5. The Design and Construction of a Simple Transmission Electron Microscope for Educational Purposes.

    Science.gov (United States)

    Hearsey, Paul K.

    This document presents a model for a simple transmission electron microscope for educational purposes. This microscope could demonstrate thermonic emission, particle acceleration, electron deflection, and flourescence. It is designed to be used in high school science courses, particularly physics, taking into account the size, weight, complexity…

  6. Removal of Vesicle Structures from Transmission Electron Microscope Images

    DEFF Research Database (Denmark)

    Jensen, Katrine Hommelhoff; Sigworth, Fred; Brandt, Sami Sebastian

    2015-01-01

    In this paper, we address the problem of imaging membrane proteins for single-particle cryo-electron microscopy reconstruction of the isolated protein structure. More precisely, we propose a method for learning and removing the interfering vesicle signals from the micrograph, prior to reconstruct...

  7. Asymmetric Wave Transmission During Electron-Cyclotron Resonant Heating

    NARCIS (Netherlands)

    Peeters, A.G.; Smits, F. M. A.; Giruzzi, G.; Oomens, A. A. M.; Westerhof, E.

    1995-01-01

    In low density plasmas in the RTP tokamak the single-pass absorption of O-mode waves at the fundamental electron cyclotron resonance is observed to be toroidally asymmetric. The absorption is highest for waves travelling in the direction opposite to the toroidal plasma current. Fokker-Planck

  8. Free electron lasers for transmission of energy in space

    Science.gov (United States)

    Segall, S. B.; Hiddleston, H. R.; Catella, G. C.

    1981-01-01

    A one-dimensional resonant-particle model of a free electron laser (FEL) is used to calculate laser gain and conversion efficiency of electron energy to photon energy. The optical beam profile for a resonant optical cavity is included in the model as an axial variation of laser intensity. The electron beam profile is matched to the optical beam profile and modeled as an axial variation of current density. Effective energy spread due to beam emittance is included. Accelerators appropriate for a space-based FEL oscillator are reviewed. Constraints on the concentric optical resonator and on systems required for space operation are described. An example is given of a space-based FEL that would produce 1.7 MW of average output power at 0.5 micrometer wavelength with over 50% conversion efficiency of electrical energy to laser energy. It would utilize a 10 m-long amplifier centered in a 200 m-long optical cavity. A 3-amp, 65 meV electrostatic accelerator would provide the electron beam and recover the beam after it passes through the amplifier. Three to five shuttle flights would be needed to place the laser in orbit.

  9. Transmission and Trapping of Cold Electrons in Water Ice

    DEFF Research Database (Denmark)

    Balog, Richard; Cicman, Peter; Field, David;

    2011-01-01

    Experiments are reported that show currents of low energy (“cold”) electrons pass unattenuated through crystalline ice at 135 K for energies between zero and 650 meV, up to the maximum studied film thickness of 430 bilayers, showing negligible apparent trapping. By contrast, both porous amorphous...

  10. Low impact to fixed cell processing aiming transmission electron microscopy

    Science.gov (United States)

    Barth, Ortrud Monika; da Silva, Marcos Alexandre Nunes; Barreto-Vieira, Debora Ferreira

    2016-01-01

    In cell culture, cell structures suffer strong impact due to centrifugation during processing for electron microscope observation. In order to minimise this effect, a new protocol was successfully developed. Using conventional reagents and equipments, it took over one week, but cell compression was reduced to none or the lowest deformation possible. PMID:27276186

  11. A Review of Electronic Devices to Assess Inhaler Technique.

    Science.gov (United States)

    Carpenter, Delesha M; Roberts, Courtney A; Sage, Adam J; George, Johnson; Horne, Robert

    2017-03-01

    Multiple electronic devices exist that provide feedback on the accuracy of patient inhaler technique. Our purpose is to describe the inhaler technique feedback provided by these devices, including specific technique steps measured, how feedback is displayed, target of feedback (patient, provider, researcher), and compatibility with inhaler type (metered-dose inhaler [MDI], diskus, etc.). We identified eight devices that provide feedback on inhaler technique. Only one device assessed all evidence-based MDI technique steps. Most devices provide limited real-time feedback to patients, if any feedback at all. Technologies to assess inhaler technique are advancing and hold great potential for improving patient inhaler technique. Many devices are limited in their ability to detect all evidence-based technique steps and provide real-time user-friendly feedback to patients and providers. Usability tests with patients and providers could identify ways to improve these devices to improve their utility in clinical settings.

  12. Enhancement of Time Reversal Sub-wavelength Wireless Transmission Using Pulse Shaping Technique (submit/1139227)

    CERN Document Server

    Ding, Shuai; Zang, Rui; Zou, Lianfeng; Wang, Bing-Zhong; Caloz, Christophe

    2014-01-01

    A novel time-reversal subwavelength transmission technique, based on pulse shaping circuits (PSCs), is proposed. This technique removes the need for complex or electrically large electromagnetic structures by generating channel diversity via pulse shaping instead of angular spectrum transformation. It is shown that, compared to our previous time-reversal system based on chirped delay lines, the PSC approach offers greater flexibility and larger possible numbers of channels, i.e. ultimately higher transmission throughput. The PSC based time-reversal system is also demonstrated experimentally.

  13. Solar Flare Track Exposure Ages in Regolith Particles: A Calibration for Transmission Electron Microscope Measurements

    Science.gov (United States)

    Berger, Eve L.; Keller, Lindsay P.

    2015-01-01

    Mineral grains in lunar and asteroidal regolith samples provide a unique record of their interaction with the space environment. Space weathering effects result from multiple processes including: exposure to the solar wind, which results in ion damage and implantation effects that are preserved in the rims of grains (typically the outermost 100 nm); cosmic ray and solar flare activity, which result in track formation; and impact processes that result in the accumulation of vapor-deposited elements, impact melts and adhering grains on particle surfaces. Determining the rate at which these effects accumulate in the grains during their space exposure is critical to studies of the surface evolution of airless bodies. Solar flare energetic particles (mainly Fe-group nuclei) have a penetration depth of a few millimeters and leave a trail of ionization damage in insulating materials that is readily observable by transmission electron microscope (TEM) imaging. The density of solar flare particle tracks is used to infer the length of time an object was at or near the regolith surface (i.e., its exposure age). Track measurements by TEM methods are routine, yet track production rate calibrations have only been determined using chemical etching techniques [e.g., 1, and references therein]. We used focused ion beam-scanning electron microscope (FIB-SEM) sample preparation techniques combined with TEM imaging to determine the track density/exposure age relations for lunar rock 64455. The 64455 sample was used earlier by [2] to determine a track production rate by chemical etching of tracks in anorthite. Here, we show that combined FIB/TEM techniques provide a more accurate determination of a track production rate and also allow us to extend the calibration to solar flare tracks in olivine.

  14. Synthesis and Activation of Catalysts for Biofuel Synthesis in an Environmental Transmission Electron Microscope

    DEFF Research Database (Denmark)

    Duchstein, Linus Daniel Leonhard; Wu, Qiongxiao; Elkjær, Christian Fink

    promising candidates experimentally. Transmission electron microscopy (TEM) is used for microstructural characterization and provides feedback for both theory and synthesis. We have studied the catalysts close to their working conditions in an environmental transmission electron microscope (ETEM) equipped...... of CuNi and NiGa catalysts for alcohol synthesis using High-Resolution TEM (HRTEM), energy electron-loss spectroscopy (EELS), Energy-Dispersive X-ray Spectroscopy (EDX). Complementary observations have been done using in-situ X-Ray Diffraction (XRD). We focus on structural changes during the catalysts...

  15. Simulations of the electron cloud buildup and its influence on the microwave transmission measurement

    Science.gov (United States)

    Haas, Oliver Sebastian; Boine-Frankenheim, Oliver; Petrov, Fedor

    2013-11-01

    An electron cloud density in an accelerator can be measured using the Microwave Transmission (MWT) method. The aim of our study is to evaluate the influence of a realistic, nonuniform electron cloud on the MWT. We conduct electron cloud buildup simulations for beam pipe geometries and bunch parameters resembling roughly the conditions in the CERN SPS. For different microwave waveguide modes the phase shift induced by a known electron cloud density is obtained from three different approaches: 3D Particle-In-Cell (PIC) simulation of the electron response, a 2D eigenvalue solver for waveguide modes assuming a dielectric response function for cold electrons, a perturbative method assuming a sufficiently smooth density profile. While several electron cloud parameters, such as temperature, result in minor errors in the determined density, the transversely inhomogeneous density can introduce a large error in the measured electron density. We show that the perturbative approach is sufficient to describe the phase shift under realistic electron cloud conditions. Depending on the geometry of the beam pipe, the external magnetic field configuration and the used waveguide mode, the electron cloud density can be concentrated at the beam pipe or near the beam pipe center, leading to a severe over- or underestimation of the electron density. Electron cloud distributions are very inhomogeneous, especially in dipoles. These inhomogeneities affect the microwave transmission measurement results. Electron density might be over- or underestimated, depending on setup. This can be quantified with several models, e.g. a perturbative approach.

  16. Robust image alignment for cryogenic transmission electron microscopy.

    Science.gov (United States)

    McLeod, Robert A; Kowal, Julia; Ringler, Philippe; Stahlberg, Henning

    2017-03-01

    Cryo-electron microscopy recently experienced great improvements in structure resolution due to direct electron detectors with improved contrast and fast read-out leading to single electron counting. High frames rates enabled dose fractionation, where a long exposure is broken into a movie, permitting specimen drift to be registered and corrected. The typical approach for image registration, with high shot noise and low contrast, is multi-reference (MR) cross-correlation. Here we present the software package Zorro, which provides robust drift correction for dose fractionation by use of an intensity-normalized cross-correlation and logistic noise model to weight each cross-correlation in the MR model and filter each cross-correlation optimally. Frames are reliably registered by Zorro with low dose and defocus. Methods to evaluate performance are presented, by use of independently-evaluated even- and odd-frame stacks by trajectory comparison and Fourier ring correlation. Alignment of tiled sub-frames is also introduced, and demonstrated on an example dataset. Zorro source code is available at github.com/CINA/zorro. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Environmental Transmission Electron Microscopy of catalysts for the methanol synthesis

    DEFF Research Database (Denmark)

    Duchstein, Linus Daniel Leonhard

    Everywhere around the world, natural resources like crude oil are becoming less and harder to extract. It is therefore necessary to find alternatives to secure our future transportation in a sustainable way. This can be done e.g. through chemical conversion of lignocelluloses into bio-alcohol thr......Everywhere around the world, natural resources like crude oil are becoming less and harder to extract. It is therefore necessary to find alternatives to secure our future transportation in a sustainable way. This can be done e.g. through chemical conversion of lignocelluloses into bio...... atmosphere and temperature was investigated. CuNi was exposed to the electron beam for 3 different intensities and 3 different temperatures while the oxidation state of the Cu2+ was measured by energy electron loss spectroscopy. It turns out that the electron beam does have an influence but it does not seem...... to scale with the beam current density but foremost with the exposure time. The ETEM shows phase and chemical changes during the reaction....

  18. Present and future techniques for automated power facility maintenance. Maintenance techniques for power transmission facilities

    Energy Technology Data Exchange (ETDEWEB)

    Taneichi, Takeshi; Takada, Nobuyuki

    1988-09-15

    Present automated information acquisition system of the maintenance services for overhead transmission lines is outlined, and in addition, the fault localization system with optical fiber composite overhead ground wires (OPGW) and fault locators, automated ice or snow coating monitoring system, and transmission tower site monitoring system are presented. As maintenance equipment, the automatic fitting equipment of low-snow coating rings, and remote measuring with a helicopter are presented. More applications of OPGW and more uses of robots for the maintenance services are pointed out as future trends. Present automated maintenance services for underground transmission lines are outlined, and in addition, the communication system of the oil leakage information of OF cables or failure information of cooling facilities, the automatic operation and monitoring system for cooling facilities, and the duct monitoring system to collect and montor operation, failure and control imformation are presented. The use of inspection robots and a computerized total facility management system are pointed out as future trends. (7 figs, 3 tabs, 3 refs)

  19. Self-assembly of silicon nanowires studied by advanced transmission electron microscopy

    Directory of Open Access Journals (Sweden)

    Marta Agati

    2017-02-01

    Full Text Available Scanning transmission electron microscopy (STEM was successfully applied to the analysis of silicon nanowires (SiNWs that were self-assembled during an inductively coupled plasma (ICP process. The ICP-synthesized SiNWs were found to present a Si–SiO2 core–shell structure and length varying from ≈100 nm to 2–3 μm. The shorter SiNWs (maximum length ≈300 nm were generally found to possess a nanoparticle at their tip. STEM energy dispersive X-ray (EDX spectroscopy combined with electron tomography performed on these nanostructures revealed that they contain iron, clearly demonstrating that the short ICP-synthesized SiNWs grew via an iron-catalyzed vapor–liquid–solid (VLS mechanism within the plasma reactor. Both the STEM tomography and STEM-EDX analysis contributed to gain further insight into the self-assembly process. In the long-term, this approach might be used to optimize the synthesis of VLS-grown SiNWs via ICP as a competitive technique to the well-established bottom-up approaches used for the production of thin SiNWs.

  20. On the optimum resolution of transmission-electron backscattered diffraction (t-EBSD).

    Science.gov (United States)

    van Bremen, R; Ribas Gomes, D; de Jeer, L T H; Ocelík, V; De Hosson, J Th M

    2016-01-01

    The work presented aims at determining the optimum physical resolution of the transmission-electron backscattered diffraction (t-EBSD) technique. The resolution depends critically on intrinsic factors such as the density, atomic number and thickness of the specimen but also on the extrinsic experimental set-up of the electron beam voltage, specimen tilt and detector position. In the present study, the so-called physical resolution of a typical t-EBSD set-up was determined with the use of Monte Carlo simulations and confronted to experimental findings. In the case of a thin Au film of 20 nm, the best resolution obtained was 9 nm whereas for a 100 nm Au film the best resolution was 66 nm. The precise dependence of resolution on thickness was found to vary differently depending on the specific elements involved. This means that the resolution of each specimen should be determined individually. Experimentally the median probe size of the t-EBSD for a 140 nm thick AuAg specimen was measured to be 87 nm. The first and third quartiles of the probe size measurements were found to be 60 nm and 118 nm. Simulation of this specimen resulted in a resolution of 94 nm which fits between these quartiles.

  1. Joint denoising and distortion correction of atomic scale scanning transmission electron microscopy images

    Science.gov (United States)

    Berkels, Benjamin; Wirth, Benedikt

    2017-09-01

    Nowadays, modern electron microscopes deliver images at atomic scale. The precise atomic structure encodes information about material properties. Thus, an important ingredient in the image analysis is to locate the centers of the atoms shown in micrographs as precisely as possible. Here, we consider scanning transmission electron microscopy (STEM), which acquires data in a rastering pattern, pixel by pixel. Due to this rastering combined with the magnification to atomic scale, movements of the specimen even at the nanometer scale lead to random image distortions that make precise atom localization difficult. Given a series of STEM images, we derive a Bayesian method that jointly estimates the distortion in each image and reconstructs the underlying atomic grid of the material by fitting the atom bumps with suitable bump functions. The resulting highly non-convex minimization problems are solved numerically with a trust region approach. Existence of minimizers and the model behavior for faster and faster rastering are investigated using variational techniques. The performance of the method is finally evaluated on both synthetic and real experimental data.

  2. Enhanced light element imaging in atomic resolution scanning transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Findlay, S.D., E-mail: scott.findlay@monash.edu [School of Physics, Monash University, Victoria 3800 (Australia); Kohno, Y. [JEOL Ltd., Tokyo 196-8558 (Japan); Cardamone, L.A. [School of Physics, Monash University, Victoria 3800 (Australia); Ikuhara, Y. [Institute of Engineering Innovation, School of Engineering, University of Tokyo, Tokyo 113-8656 (Japan); Nanostructures Research Laboratory, Japan Fine Ceramics Center, Nagoya 456-8587 (Japan); WPI Advanced Institute for Materials Research, Tohoku University, Sendai 980-8577 (Japan); Shibata, N. [Institute of Engineering Innovation, School of Engineering, University of Tokyo, Tokyo 113-8656 (Japan); PRESTO, Japan Science and Technology Agency, Saitama 332-0012 (Japan)

    2014-01-15

    We show that an imaging mode based on taking the difference between signals recorded from the bright field (forward scattering region) in atomic resolution scanning transmission electron microscopy provides an enhancement of the detectability of light elements over existing techniques. In some instances this is an enhancement of the visibility of the light element columns relative to heavy element columns. In all cases explored it is an enhancement in the signal-to-noise ratio of the image at the light column site. The image formation mechanisms are explained and the technique is compared with earlier approaches. Experimental data, supported by simulation, are presented for imaging the oxygen columns in LaAlO{sub 3}. Case studies looking at imaging hydrogen columns in YH{sub 2} and lithium columns in Al{sub 3}Li are also explored through simulation, particularly with respect to the dependence on defocus, probe-forming aperture angle and detector collection aperture angles. - Author-Highlights: • We present a method for enhancing the visibility and reliability of imaging light elements in STEM. • The method involves taking the difference between signals on separate bright field detectors. • Experimental data for LaAlO{sub 3} are presented, and are shown to compare favourably with simulation. • Optimum imaging parameters are explored through simulation.

  3. Characterization of organic thin films using transmission electron microscopy and Fourier Transform Infra Red spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Bhansali, Unnat S.; Quevedo Lopez, M.A.; Jia Huiping; Alshareef, H.N.; Cha, Dong Kyu; Kim, M.J. [Department of Materials Science and Engineering, Erik Jonsson School of Engineering and Computer Science, University of Texas at Dallas, Richardson, Texas 75080 (United States); Gnade, Bruce E., E-mail: gnade@utdallas.ed [Department of Materials Science and Engineering, Erik Jonsson School of Engineering and Computer Science, University of Texas at Dallas, Richardson, Texas 75080 (United States)

    2009-08-31

    Organic Light Emitting Diodes (OLEDs) have received much attention for use in display and solid-state lighting applications. Consequently, evaluating materials analyses techniques to better understand potential issues between the different films constituting the OLED device structure becomes important. In particular, film thickness monitoring and control is essential for reproducible and reliable OLED performance. Typically, Quartz Crystal Microbalances (QCMs) are used to monitor the thicknesses in-situ. While QCMs can provide thickness information, they do not provide information about the composition or quality of the deposited films. To overcome these issues, in this paper, we have used Fourier Transform InfraRed Spectroscopy (FT-IR) to measure film thicknesses and compositions in individual as well as stacked organic layers relevant to OLED structures and used cross-sectional Transmission Electron Microscopy imaging to correlate the physical thickness of the organic films to their IR (infrared) absorption peak intensities from FT-IR. We demonstrate that this technique can be used to precisely measure film thicknesses within 5% of the nominal thickness and provide information about film composition.

  4. Electron transmission in normal/heavy-fermion superconductor junctions

    OpenAIRE

    Araujo, M. A. N; Sacramento, P. D.

    2008-01-01

    The Andreev reflection between a normal metal (N) and a heavy-fermion superconductor (HFS) is studied and the boundary conditions for the electron's wave function in the two systems are established in the framework of a two band model for the HFS. Hence we show in a simple and explicit way that the mass enhancement factors in the heavy-fermion (HF) metal do not cause impedance at the N/HFS interface, in accordance with arguments previously presented. We also present an extension of the theory...

  5. Development of Wireless Techniques in Data and Power Transmission - Application for Particle Physics Detectors

    CERN Document Server

    Brenner, R; Dehos, C; De Lurgio, P; Djurcic, Z; Drake, G; Gimenez, J L Gonzalez; Gustafsson, L; Kim, D W; Locci, E; Roehrich, D; Schoening, A; Siligaris, A; Soltveit, H K; Ullaland, K; Vincent, P; Wiednert, D; Yang, S

    2015-01-01

    Wireless techniques have developed extremely fast over the last decade and using them for data and power transmission in particle physics detectors is not science- fiction any more. During the last years several research groups have independently thought of making it a reality. Wireless techniques became a mature field for research and new developments might have impact on future particle physics experiments. The Instrumentation Frontier was set up as a part of the SnowMass 2013 Community Summer Study [1] to examine the instrumentation R&D for the particle physics research over the coming decades: {\\guillemotleft} To succeed we need to make technical and scientific innovation a priority in the field {\\guillemotright}. Wireless data transmission was identified as one of the innovations that could revolutionize the transmission of data out of the detector. Power delivery was another challenge mentioned in the same report. We propose a collaboration to identify the specific needs of different projects that m...

  6. Information extraction and transmission techniques for spaceborne synthetic aperture radar images

    Science.gov (United States)

    Frost, V. S.; Yurovsky, L.; Watson, E.; Townsend, K.; Gardner, S.; Boberg, D.; Watson, J.; Minden, G. J.; Shanmugan, K. S.

    1984-01-01

    Information extraction and transmission techniques for synthetic aperture radar (SAR) imagery were investigated. Four interrelated problems were addressed. An optimal tonal SAR image classification algorithm was developed and evaluated. A data compression technique was developed for SAR imagery which is simple and provides a 5:1 compression with acceptable image quality. An optimal textural edge detector was developed. Several SAR image enhancement algorithms have been proposed. The effectiveness of each algorithm was compared quantitatively.

  7. Electron Correlation Microscopy: A New Technique for Studying Local Atom Dynamics Applied to a Supercooled Liquid.

    Science.gov (United States)

    He, Li; Zhang, Pei; Besser, Matthew F; Kramer, Matthew Joseph; Voyles, Paul M

    2015-08-01

    Electron correlation microscopy (ECM) is a new technique that utilizes time-resolved coherent electron nanodiffraction to study dynamic atomic rearrangements in materials. It is the electron scattering equivalent of photon correlation spectroscopy with the added advantage of nanometer-scale spatial resolution. We have applied ECM to a Pd40Ni40P20 metallic glass, heated inside a scanning transmission electron microscope into a supercooled liquid to measure the structural relaxation time τ between the glass transition temperature T g and the crystallization temperature, T x . τ determined from the mean diffraction intensity autocorrelation function g 2(t) decreases with temperature following an Arrhenius relationship between T g and T g +25 K, and then increases as temperature approaches T x . The distribution of τ determined from the g 2(t) of single speckles is broad and changes significantly with temperature.

  8. Effects of Topography in Nano-Structured Thin Films : A Lorentz Transmission Electron Microscopy and Electron Holography Study

    NARCIS (Netherlands)

    Hosson, Jeff Th.M. De; Raedt, Hans A. De

    2003-01-01

    This paper aims at applying advanced transmission electron microscopy (TEM) to functional materials, such as ultra-soft magnetic films for high-frequency inductors, to reveal the structure-property relationship. The ultimate goal is to delineate a more quantitative way to obtain information of the

  9. Robotized semiautomatic motorcycle transmission development. Electronic and software design

    Directory of Open Access Journals (Sweden)

    Neghină Mihai

    2017-01-01

    Full Text Available In this paper, we propose an electrical design (implemented on a PCB board and an accompanying software design for controlling the automatic gear change. The designs complement the mechanical solutions developed in Part 1. The paper also analyses the issues encountered during the intermediate steps of the development of the electronic module, which is expected to be small and adaptable enough to be installed on a motorcycle without changing its ergonomics. The control software runs on the Arduino Nano board and is built as a state machine with one idle state, five active states that cover different stages of the gear change and one error state for preventing malfunctions in case of an unexpected event. The sketch uses 5,760 bytes (or 18% of program storage space and 706 bytes (or 34% of the dynamic memory.

  10. In Situ Transmission Electron Microscopy of Cadmium Selenide Nanorod Sublimation.

    Science.gov (United States)

    Hellebusch, Daniel J; Manthiram, Karthish; Beberwyck, Brandon J; Alivisatos, A Paul

    2015-02-19

    In situ electron microscopy is used to observe the morphological evolution of cadmium selenide nanorods as they sublime under vacuum at a series of elevated temperatures. Mass loss occurs anisotropically along the nanorod's long axis. At temperatures close to the sublimation threshold, the phase change occurs from both tips of the nanorods and proceeds unevenly with periods of rapid mass loss punctuated by periods of relative stability. At higher temperatures, the nanorods sublime at a faster, more uniform rate, but mass loss occurs from only a single end of the rod. We propose a mechanism that accounts for the observed sublimation behavior based on the terrace-ledge-kink (TLK) model and how the nanorod surface chemical environment influences the kinetic barrier of sublimation.

  11. Diagnostic techniques for measuring suprathermal electron dynamics in plasmas (invited).

    Science.gov (United States)

    Coda, S

    2008-10-01

    Plasmas, both in the laboratory and in space, are often not in thermodynamic equilibrium, and the plasma electron distribution function is accordingly non-Maxwellian. Suprathermal electron tails can be generated by external drives, such as rf waves and electric fields, or internal ones, such as instabilities and magnetic reconnection. The variety and importance of the phenomena in which suprathermal electrons play a significant role explains an enduring interest in diagnostic techniques to investigate their properties and dynamics. X-ray bremsstrahlung emission has been studied in hot magnetized plasmas for well over two decades, flanked progressively by electron-cyclotron emission in geometries favoring the high-energy end of the distribution function (high-field-side, vertical, oblique emission), by electron-cyclotron absorption, by spectroscopic techniques, and at lower temperatures, by Langmuir probes and electrostatic analyzers. Continuous progress in detector technology and in measurement and analysis techniques, increasingly sophisticated layouts (multichannel and tomographic systems, imaging geometries), and highly controlled suprathermal generation methods (e.g., perturbative rf modulation) have all been brought to bear in recent years on an increasingly detailed, although far from complete, understanding of suprathermal electron dynamics.

  12. Measurement of vibrational spectrum of liquid using monochromated scanning transmission electron microscopy-electron energy loss spectroscopy.

    Science.gov (United States)

    Miyata, Tomohiro; Fukuyama, Mao; Hibara, Akihide; Okunishi, Eiji; Mukai, Masaki; Mizoguchi, Teruyasu

    2014-10-01

    Investigations on the dynamic behavior of molecules in liquids at high spatial resolution are greatly desired because localized regions, such as solid-liquid interfaces or sites of reacting molecules, have assumed increasing importance with respect to improving material performance. In application to liquids, electron energy loss spectroscopy (EELS) observed with transmission electron microscopy (TEM) is a promising analytical technique with the appropriate resolutions. In this study, we obtained EELS spectra from an ionic liquid, 1-ethyl-3-methylimidazolium bis (trifluoromethyl-sulfonyl) imide (C2mim-TFSI), chosen as the sampled liquid, using monochromated scanning TEM (STEM). The molecular vibrational spectrum and the highest occupied molecular orbital (HOMO)-lowest unoccupied molecular orbital (LUMO) gap of the liquid were investigated. The HOMO-LUMO gap measurement coincided with that obtained from the ultraviolet-visible spectrum. A shoulder in the spectrum observed ∼0.4 eV is believed to originate from the molecular vibration. From a separately performed infrared observation and first-principles calculations, we found that this shoulder coincided with the vibrational peak attributed to the C-H stretching vibration of the [C2mim(+)] cation. This study demonstrates that a vibrational peak for a liquid can be observed using monochromated STEM-EELS, and leads one to expect observations of chemical reactions or aids in the analysis of the dynamic behavior of molecules in liquid. © The Author 2014. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  13. Proton Transmitting Energy Spectra and Transmission Electron Microscope Examinations of Biological Samples

    Science.gov (United States)

    Tan, Chun-yu; Xia, Yue-yuan; Zhang, Jian-hua; Mu, Yu-guang; Wang, Rui-jin; Liu, Ji-tian; Liu, Xiang-dong; Yu, Zeng-liang

    1999-02-01

    Transmission energy spectra of 530 keV H+ ion penetrating 140 μm thick seed coat of maize and fruit peel of grape with thickness of 100 μm were measured. The result indicates that these thick biological targets, as seen by the penetrating ions, are inhomogeneous, and there are open "channel like" paths along which the incident ions can transmit the targets easily. While most of the incident ions are stopped in the targets, some of the transmitting ions only lose a small fraction of their initial incident energy. The transmission energy spectra show a pure electronic stopping feature. Transmission electron microscope (TEM) micrographes taken from the samples of seed coat of maize and fruit peel of tomato with thickness of 60 μm indicate that 150 keV electron beam from the TEM can penetrate the thick samples to give very good images with clear contrasts.

  14. A novel exact solution to transmission problem of electron wave in a nonlinear Kronig-Penney superlattice

    Science.gov (United States)

    Kong, Chao; Hai, Kuo; Tan, Jintao; Chen, Hao; Hai, Wenhua

    2016-03-01

    Nonlinear Kronig-Penney model has been frequently employed to study transmission problem of electron wave in a doped semiconductor superlattice or in a nonlinear electrified chain. Here from an integral equation we derive a novel exact solution of the problem, which contains a simple nonlinear map connecting transmission coefficient with system parameters. Consequently, we propose a scheme to manipulate electronic distribution and transmission by adjusting the system parameters. A new quantum coherence effect is evidenced by the strict expression of transmission coefficient, which results in the aperiodic electronic distributions and different transmission coefficients including the approximate zero transmission and total transmission, and the multiple transmissions. The method based on the concise exact solution can be applied directly to some nonlinear cold atomic systems and a lot of linear Kronig-Penney systems, and also can be extended to investigate electronic transport in different discrete nonlinear systems.

  15. Aberration-corrected scanning transmission electron microscopy for complex transition metal oxides

    Science.gov (United States)

    Qing-Hua, Zhang; Dong-Dong, Xiao; Lin, Gu

    2016-06-01

    Lattice, charge, orbital, and spin are the four fundamental degrees of freedom in condensed matter, of which the interactive coupling derives tremendous novel physical phenomena, such as high-temperature superconductivity (high-T c SC) and colossal magnetoresistance (CMR) in strongly correlated electronic system. Direct experimental observation of these freedoms is essential to understanding the structure-property relationship and the physics behind it, and also indispensable for designing new materials and devices. Scanning transmission electron microscopy (STEM) integrating multiple techniques of structure imaging and spectrum analysis, is a comprehensive platform for providing structural, chemical and electronic information of materials with a high spatial resolution. Benefiting from the development of aberration correctors, STEM has taken a big breakthrough towards sub-angstrom resolution in last decade and always steps forward to improve the capability of material characterization; many improvements have been achieved in recent years, thereby giving an in-depth insight into material research. Here, we present a brief review of the recent advances of STEM by some representative examples of perovskite transition metal oxides; atomic-scale mapping of ferroelectric polarization, octahedral distortions and rotations, valence state, coordination and spin ordering are presented. We expect that this brief introduction about the current capability of STEM could facilitate the understanding of the relationship between functional properties and these fundamental degrees of freedom in complex oxides. Project supported by the National Key Basic Research Project, China (Grant No. 2014CB921002), the Strategic Priority Research Program of Chinese Academy of Sciences (Grant No. XDB07030200), and the National Natural Science Foundation of China (Grant Nos. 51522212 and 51421002).

  16. Visualization of newt aragonitic otoconial matrices using transmission electron microscopy

    Science.gov (United States)

    Steyger, P. S.; Wiederhold, M. L.

    1995-01-01

    Otoconia are calcified protein matrices within the gravity-sensing organs of the vertebrate vestibular system. These protein matrices are thought to originate from the supporting or hair cells in the macula during development. Previous studies of mammalian calcitic, barrel-shaped otoconia revealed an organized protein matrix consisting of a thin peripheral layer, a well-defined organic core and a flocculent matrix inbetween. No studies have reported the microscopic organization of the aragonitic otoconial matrix, despite its protein characterization. Pote et al. (1993b) used densitometric methods and inferred that prismatic (aragonitic) otoconia have a peripheral protein distribution, compared to that described for the barrel-shaped, calcitic otoconia of birds, mammals, and the amphibian utricle. By using tannic acid as a negative stain, we observed three kinds of organic matrices in preparations of fixed, decalcified saccular otoconia from the adult newt: (1) fusiform shapes with a homogenous electron-dense matrix; (2) singular and multiple strands of matrix; and (3) more significantly, prismatic shapes outlined by a peripheral organic matrix. These prismatic shapes remain following removal of the gelatinous matrix, revealing an internal array of organic matter. We conclude that prismatic otoconia have a largely peripheral otoconial matrix, as inferred by densitometry.

  17. Scanning and Transmission Electron Microscopy of High Temperature Materials

    Science.gov (United States)

    1994-01-01

    Software and hardware updates to further extend the capability of the electron microscope were carried out. A range of materials such as intermetallics, metal-matrix composites, ceramic-matrix composites, ceramics and intermetallic compounds, based on refractory elements were examined under this research. Crystal structure, size, shape and volume fraction distribution of various phases which constitute the microstructures were examined. Deformed materials were studied to understand the effect of interfacial microstructure on the deformation and fracture behavior of these materials. Specimens tested for a range of mechanical property requirements, such as stress rupture, creep, low cycle fatigue, high cycle fatigue, thermomechanical fatigue, etc. were examined. Microstructural and microchemical stability of these materials exposed to simulated operating environments were investigated. The EOIM Shuttle post-flight samples were also examined to understand the influence of low gravity processing on microstructure. In addition, fractographic analyses of Nb-Zr-W, titanium aluminide, molybdenum silicide and silicon carbide samples were carried out. Extensive characterization of sapphire fibers in the fiber-reinforced composites made by powder cloth processing was made. Finally, pressure infiltration casting of metal-matrix composites was carried out.

  18. Transmission properties of Dirac electrons through Cantor monolayer graphene superlattices

    Directory of Open Access Journals (Sweden)

    R. Rodríguez-González

    2014-01-01

    Full Text Available En este trabajo usamos el método de la matriz de transferencia para estudiar el tunelamiento de los electrones de Dirac a través de superredes aperiodicas en grafeno. Consideramos una hoja de grafeno depositada encima de bloques de sustratos de Óxido de Silicio (SiO2 y Carburo de Silicio (SiC, en los cuales aplicamos la serie de Cantor. Calculamos la transmitancia para diferentes parámetros fundamentales tales como: ancho de partida, energía de incidencia, ángulo de incidencia y número de generación de la serie de Cantor. En este caso, la transmitancia como función de la energía presenta rasgos autosimilares al variar el número de generación. También computamos la distribución angular de la transmitancia para energías fijas econtrando un patrón autosimilar entre generaciones. Por último, calculamos los factores de escala para algunos espectros de la transmitancia, los cuales efectivamente muestran escalabilidad.

  19. Macroporous silicon membranes as electron and x-ray transmissive windows

    OpenAIRE

    Schilling, J.; Scherer, A; Gösele, U; Kolbe, M.

    2004-01-01

    Macroporous silicon membranes are fabricated whose pores are terminated with 60 nm thin silicon dioxide shells. The transmission of electrons with energies of 5 kV-25 kV through these membranes was investigated reaching a maximum of 22% for 25 kV. Furthermore, the transmission of electromagnetic radiation ranging from the far-infrared to the x-ray region was determined. The results suggest the application of the membrane as window material for electron optics and energy dispersive x-ray detec...

  20. Anatomy-based transmission factors for technique optimization in portable chest x-ray

    Science.gov (United States)

    Liptak, Christopher L.; Tovey, Deborah; Segars, William P.; Dong, Frank D.; Li, Xiang

    2015-03-01

    Portable x-ray examinations often account for a large percentage of all radiographic examinations. Currently, portable examinations do not employ automatic exposure control (AEC). To aid in the design of a size-specific technique chart, acrylic slabs of various thicknesses are often used to estimate x-ray transmission for patients of various body thicknesses. This approach, while simple, does not account for patient anatomy, tissue heterogeneity, and the attenuation properties of the human body. To better account for these factors, in this work, we determined x-ray transmission factors using computational patient models that are anatomically realistic. A Monte Carlo program was developed to model a portable x-ray system. Detailed modeling was done of the x-ray spectrum, detector positioning, collimation, and source-to-detector distance. Simulations were performed using 18 computational patient models from the extended cardiac-torso (XCAT) family (9 males, 9 females; age range: 2-58 years; weight range: 12-117 kg). The ratio of air kerma at the detector with and without a patient model was calculated as the transmission factor. Our study showed that the transmission factor decreased exponentially with increasing patient thickness. For the range of patient thicknesses examined (12-28 cm), the transmission factor ranged from approximately 21% to 1.9% when the air kerma used in the calculation represented an average over the entire imaging field of view. The transmission factor ranged from approximately 21% to 3.6% when the air kerma used in the calculation represented the average signals from two discrete AEC cells behind the lung fields. These exponential relationships may be used to optimize imaging techniques for patients of various body thicknesses to aid in the design of clinical technique charts.

  1. Coordinated multi-point transmission technique in TDD cellular mobile system

    Institute of Scientific and Technical Information of China (English)

    Sun Shaohui; Gao Qiubin; Rakesh Tamrakar; Wang Yingmin

    2011-01-01

    Coordinated multi-point transmission/reception, CoMP, technique converts the interference signal into the useful information by controlling the interfering signals among adjacent cells. Theoretically, it is a breakthrough from the traditional interference limited non-cooperative single point transmission system, improving link reliability and enhancing the data rate. CoMP is regarded as one of the most essential and effective techniques in eliminating the inter-cell interference, boosting cell edge throughput and overall system throughput. CoMP technique has obvious advantages in TDD (time division duplexing) cellular mobile system; the necessary channel state information for CoMP can be easily obtained through channel reciprocity property in TDD system. CoMP scheme in TDD system and likely problems are analyzed in this paper, and it is shown by system simulations that the significant gain can be achieved.

  2. 40 CFR Appendix A to Subpart E of... - Interim Transmission Electron Microscopy Analytical Methods-Mandatory and Nonmandatory-and...

    Science.gov (United States)

    2010-07-01

    ..., Subpt. E, App. A Appendix A to Subpart E of Part 763—Interim Transmission Electron Microscopy Analytical... completion of response actions. This unit is mandatory. II. Mandatory Transmission Electron Microscopy Method... sample. 17. PCM—Phase contrast microscopy. 18. SAED—Selected area electron diffraction. 19....

  3. Transmission Electron Microscopy of the Textured Silver Back Reflector of a Thin Film Silicon Solar Cell: From Crystallography to Optical Absorption

    DEFF Research Database (Denmark)

    Duchamp, Martial; Söderström, K.; Jeangros, Q.

    2011-01-01

    the creation of surface plasmon polaritons. Here, we use transmission electron microscopy (TEM) techniques to study the grain structure of a Ag thin-film that was sputtered on top of 2-μm-thick rough ZnO layer - defects, such as twin-boundaries have been observed. A smoothing of the top Ag surface was also...

  4. Transmission Electron Microscopy of Cometary Residues from Micron-Sized Craters in the Stardust Al-Foils

    Science.gov (United States)

    Leroux, Hugues; Stroud, Rhonda M.; Dai, Zu Rong; Graham, Giles A.; Troadec, David; Bradley, John P.; Teslich, Nick; Borg, Janet; Kearsley, Anton T.; Horz, Friedrich

    2008-01-01

    We report Transmission Electron Microscopy (TEM) investigations of micro-craters that originated from hypervelocity impacts of comet 81P/Wild 2 dust particles on the aluminium foil of the Stardust collector. The craters were selected by Scanning Electron Microscopy (SEM) and then prepared by Focused Ion Beam (FIB) milling techniques in order to provide electron transparent cross-sections for TEM studies. The crater residues contain both amorphous and crystalline materials in varying proportions and compositions. The amorphous component is interpreted as resulting from shock melting during the impact and the crystalline phases as relict minerals. The latter show evidence for shock metamorphism. Based on the residue morphology and the compositional variation, the impacting particles are inferred to have been dominated by mixtures of submicron olivine, pyroxene and Fe-sulfide grains, in agreement with prior results of relatively coarse-grained mineral assemblages in the aerogel collector.

  5. In situ observation of Cu-Ni alloy nanoparticle formation by X-ray diffraction, X-ray absorption spectroscopy, and transmission electron microscopy: Influence of Cu/Ni ratio

    DEFF Research Database (Denmark)

    Wu, Qiongxiao; Duchstein, Linus Daniel Leonhard; Chiarello, Gian Luca

    2014-01-01

    Silica-supported, bimetallic Cu-Ni nanomaterials were prepared with different ratios of Cu to Ni by incipient wetness impregnation without a specific calcination step before reduction. Different in situ characterization techniques, in particular transmission electron microscopy (TEM), X-ray diffr......Silica-supported, bimetallic Cu-Ni nanomaterials were prepared with different ratios of Cu to Ni by incipient wetness impregnation without a specific calcination step before reduction. Different in situ characterization techniques, in particular transmission electron microscopy (TEM), X...

  6. Electronics system design techniques for safety critical applications

    CERN Document Server

    Sterpone, Luca

    2008-01-01

    Addresses the development of techniques for the evaluation and the hardening of designs implemented on SRAM-based Field Programmable Gate Arrays. This title presents a design methodology solving industrial designer''s needs for implementing electronic systems using SRAM-based FPGAs in critical environments, like the space or avionic ones.

  7. Three real-space discretization techniques in electronic structure calculations

    NARCIS (Netherlands)

    Torsti, T; Eirola, T; Enkovaara, J; Hakala, T; Havu, P; Havu, [No Value; Hoynalanmaa, T; Ignatius, J; Lyly, M; Makkonen, [No Value; Rantala, TT; Ruokolainen, J; Ruotsalainen, K; Rasanen, E; Saarikoski, H; Puska, MJ

    2006-01-01

    A characteristic feature of the state-of-the-art of real-space methods in electronic structure calculations is the diversity of the techniques used in the discretization of the relevant partial differential equations. In this context, the main approaches include finite-difference methods, various ty

  8. Choice of operating voltage for a transmission electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Egerton, R.F., E-mail: regerton@ualberta.ca

    2014-10-15

    An accelerating voltage of 100–300 kV remains a good choice for the majority of TEM or STEM specimens, avoiding the expense of high-voltage microscopy but providing the possibility of atomic resolution even in the absence of lens-aberration correction. For specimens thicker than a few tens of nm, the image intensity and scattering contrast are likely to be higher than at lower voltage, as is the visibility of ionization edges below 1000 eV (as required for EELS elemental analysis). In thick (>100 nm) specimens, higher voltage ensures less beam broadening and better spatial resolution for STEM imaging and EDX spectroscopy. Low-voltage (e.g. 30 kV) TEM or STEM is attractive for a very thin (e.g. 10 nm) specimen, as it provides higher scattering contrast and fewer problems for valence-excitation EELS. Specimens that are immune to radiolysis suffer knock-on damage at high current densities, and this form of radiation damage can be reduced or avoided by choosing a low accelerating voltage. Low-voltage STEM with an aberration-corrected objective lens (together with a high-angle dark-field detector and/or EELS) offers atomic resolution and elemental identification from very thin specimens. Conventional TEM can provide atomic resolution in low-voltage phase-contrast images but requires correction of chromatic aberration and preferably an electron-beam monochromator. Many non-conducting (e.g. organic) specimens damage easily by radiolysis and radiation damage then determines the TEM image resolution. For bright-field scattering contrast, low kV can provide slightly better dose-limited resolution if the specimen is very thin (a few nm) but considerably better resolution is possible from a thicker specimen, for which higher kV is required. Use of a phase plate in a conventional TEM offers the most dose-efficient way of achieving atomic resolution from beam-sensitive specimens. - Highlights: • 100–300 kV accelerating voltage is suitable for TEM specimens of typical

  9. Atom probe tomography and transmission electron microscopy of a Mg-doped AlGaN/GaN superlattice

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, S.E., E-mail: sb534@cam.ac.uk [Department of Materials Science and Metallurgy, University of Cambridge, Pembroke Street, Cambridge CB2 3QZ (United Kingdom); Ulfig, R.M.; Clifton, P.H. [Imago Scientific Instruments Corporation, 5500 Nobel Drive, Madison, WI 53711 (United States); Kappers, M.J.; Barnard, J.S.; Humphreys, C.J.; Oliver, R.A. [Department of Materials Science and Metallurgy, University of Cambridge, Pembroke Street, Cambridge CB2 3QZ (United Kingdom)

    2011-02-15

    The electronic characteristics of semiconductor-based devices are greatly affected by the local dopant atom distribution. In Mg-doped GaN, the clustering of dopants at structural defects has been widely reported, and can significantly affect p-type conductivity. We have studied a Mg-doped AlGaN/GaN superlattice using transmission electron microscopy (TEM) and atom probe tomography (APT). Pyramidal inversion domains were observed in the TEM and the compositional variations of the dopant atoms associated with those defects have been studied using APT. Rarely has APT been used to assess the compositional variations present due to structural defects in semiconductors. Here, TEM and APT are used in a complementary fashion, and the strengths and weaknesses of the two techniques are compared. -- Research Highlights: {yields} Mg-rich regions of approximately 5 nm in size were revealed in Mg-doped AlGaN/GaN superlattices using atom probe tomography (APT). {yields} Transmission electron microscopy (TEM) of the superlattice sample showed pyramidal inversion domains, concluded to be the same Mg-rich features observed by APT. {yields} The information gained from both the 3D APT study and the 2D TEM characterisation was then compared to determine the strengths and weaknesses of each technique in analysing nanoscale features in nitride materials.

  10. Design and implementation of a fs-resolved transmission electron microscope based on thermionic gun technology

    Science.gov (United States)

    Piazza, L.; Masiel, D. J.; LaGrange, T.; Reed, B. W.; Barwick, B.; Carbone, Fabrizio

    2013-09-01

    In this paper, the design and implementation of a femtosecond-resolved ultrafast transmission electron microscope is presented, based on a thermionic gun geometry. Utilizing an additional magnetic lens between the electron acceleration and the nominal condenser lens system, a larger percentage of the electrons created at the cathode are delivered to the specimen without degrading temporal, spatial and energy resolution significantly, while at the same time maintaining the femtosecond temporal resolution. Using the photon-induced near field electron microscopy effect (PINEM) on silver nanowires the cross-correlation between the light and electron pulses was measured, showing the impact of the gun settings and initiating laser pulse duration on the electron bunch properties. Tuneable electron pulses between 300 fs and several ps can be obtained, and an overall energy resolution around 1 eV was achieved.

  11. Measurement of Local Si-Nanowire Growth Kinetics Using In situ Transmission Electron Microscopy of Heated Cantilevers

    DEFF Research Database (Denmark)

    Kallesøe, Christian; Wen, Cheng-Yen; Mølhave, Kristian;

    2010-01-01

    A technique to study nanowire growth processes on locally heated microcantilevers in situ in a transmission electron microscope has been developed. The in situ observations allow the characterization of the nucleation process of silicon wires, as well as the measurement of growth rates...... of individual nanowires and the ability to observe the formation of nanowire bridges between separate cantilevers to form a complete nanowire device. How well the nanowires can be nucleated controllably on typical cantilever sidewalls is examined, and the measurements of nanowire growth rates are used...

  12. Resonant Transmission of Electron Spin States through Multiple Aharonov-Bohm Rings

    Science.gov (United States)

    Cutright, Jim; Hedin, Eric; Joe, Yong

    2011-10-01

    An Aharonov-Bohm (AB) ring with embedded quantum dots (QD) in each arm and one -dimensional nanowires attached as leads acts as a primitive cell in this analysis. When a tunable, external magnetic field is parallel to the surface area of the ring it causes Zeeman splitting in the energy levels of the QDs. An electron that traverses these energy levels has the potential to interfere with other electrons and to produce spin polarized output. It is already known that upon output the transmission of the electrons through this system will have a resonant peak at each Zeeman split energy level. A system where multiple AB rings are connected in series is studied, to see how having the electrons pass through multiple, identical rings effects the resonant peaks in the transmission and the degree of spin polarization.

  13. Multifractal scaling of electronic transmission resonances in perfect and imperfect Fibonacci δ-function potentials

    Science.gov (United States)

    Thakur, PrabhatK.; Biswas, Parthapratim

    We present here a detailed multifractal scaling study for the electronic transmission resonances with the system size for an infinitely large one-dimensional perfect and imperfect quasiperiodic system represented by a sequence of δ-function potentials. The electronic transmission resonances in the energy minibands manifest more and more fragmented nature of the transmittance with the change of system size. We claim that when a small perturbation is randomly present at a few number of sites or layers, the nature of electronic states will change and this can be understood by studying the electronic transmittance with the change of system size. We report the different critical states manifested in the size variation of the transmittance corresponding to the resonant energies for both perfect and imperfect cases through multifractal scaling study for few of these resonances.

  14. A Comprehensive Review of Embedded Transmission Pricing Methods Based on Power Flow Tracing Techniques

    Directory of Open Access Journals (Sweden)

    Baseem Khan

    2013-01-01

    Full Text Available Restructuring of electricity supply industry introduced the concept of deregulation. After deregulation transmission cost allocation is a vital issue. In the available literature, various authors have presented different methods for allocation of transmission cost. This paper presents the review of a variety of methods and algorithm based on the principle of power-flow tracing. For a fair and equitable transmission charge allocation it is necessary to know the quantum of power flowing by each generator and load in line flows. Power flow tracing techniques are mainly based on the concepts of proportional sharing principle, graph theory, circuit theory (Z-bus tracing, optimization approach, relative electrical distance concept, Equilateral bilateral exchange (EBE, and game theory. This paper presents a comprehensive review of all the available literature on the above.

  15. Electronic compensation technique to deliver a total body dose

    Science.gov (United States)

    Lakeman, Tara E.

    Purpose: Total body irradiation (TBI) uses large parallel-opposed radiation fields to suppress the patient's immune system and eradicate the residual cancer cells in preparation of recipient for bone marrow transplant. The manual placement of lead compensators has been conventionally used to compensate for the varying thickness throughout the body in large-field TBI. The goal of this study is to pursue utilizing the modern electronic compensation technique to more accurately and efficiently deliver dose to patients in need of TBI. Method: Treatment plans utilizing the electronic compensation to deliver a total body dose were created retrospectively for patients for whom CT data had been previously acquired. Each treatment plan includes two pair of parallel opposed fields. One pair of large fields is used to encompass the majority of the patient's anatomy. The other pair are very small open fields focused only on the thin bottom portion of the patient's anatomy, which requires much less radiation than the rest of the body to reach 100% of the prescribed dose. A desirable fluence pattern was manually painted within each of the larger fields for each patient to provide a more uniform distribution. Results: Dose-volume histograms (DVH) were calculated for evaluating the electronic compensation technique. In the electronically compensated plans, the maximum body doses calculated from the DVH were reduced from the conventionally-compensated plans by an average of 15%, indicating a more uniform dose. The mean body doses calculated from the electronically compensated DVH remained comparable to that of the conventionally-compensated plans, indicating an accurate delivery of the prescription dose using electronic compensation. All calculated monitor units were within clinically acceptable limits. Conclusion: Electronic compensation technique for TBI will not increase the beam on time beyond clinically acceptable limits while it can substantially reduce the compensator setup

  16. Characterization of electron clouds in the Cornell Electron Storage Ring Test Accelerator using TE-wave transmission

    Energy Technology Data Exchange (ETDEWEB)

    De Santis, S.; Byrd, J. M.; Billing, M.; Palmer, M.; Sikora, J.; Carlson, B.

    2010-01-02

    A relatively new technique for measuring the electron cloud density in storage rings has been developed and successfully demonstrated [S. De Santis, J.M. Byrd, F. Caspers, A. Krasnykh, T. Kroyer, M.T.F. Pivi, and K.G. Sonnad, Phys. Rev. Lett. 100, 094801 (2008).]. We present the experimental results of a systematic application of this technique at the Cornell Electron Storage Ring Test Accelerator. The technique is based on the phase modulation of the TE mode transmitted in a synchrotron beam pipe caused by the periodic variation of the density of electron plasma. Because of the relatively simple hardware requirements, this method has become increasingly popular and has been since successfully implemented in several machines. While the principles of this technique are straightforward, quantitative derivation of the electron cloud density from the measurement requires consideration of several effects, which we address in detail.

  17. Absorption-edge transmission technique using Ce- 139 for measurement of stable iodine concentration.

    Science.gov (United States)

    Sorenson, J A

    1979-12-01

    We have investigated a technique for measuring stable iodine concentrations by absorption-edge transmission measurements using a Ce 139 radiation source. The lanthanum daughter emits characteristic x-rays whose energies just bracket the absorption edge of iodine at 33.2 keV. Relative transmission of these x-rays is sensitive to iodine concentration in the sample, but is relatively insensitive to other elements. By applying energy-selective beam filtration, it is possible to determine the relative transmission of these closely spaced x-ray energies with NaI(Tl) detectors. Optimizations of sample thickness, detector thickness, and Ce-139 source activity are discussed. Using sample volumes of about 10 ml, one can determine iodine concentration to an uncertainty (standard deviation) of +/- 5 microgram/ml with a 5-mCi source in a measurement time of 400 sec. Potential clinical applications of the in vitro technique are discussed, along with comparative aspects of the Ce-139 technique and other absorption and fluorescence techniques for measuring stable iodine.

  18. A Simple Transmission Electron Microscopy Method for Fast Thickness Characterization of Suspended Graphene and Graphite Flakes.

    Science.gov (United States)

    Rubino, Stefano; Akhtar, Sultan; Leifer, Klaus

    2016-02-01

    We present a simple, fast method for thickness characterization of suspended graphene/graphite flakes that is based on transmission electron microscopy (TEM). We derive an analytical expression for the intensity of the transmitted electron beam I 0(t), as a function of the specimen thickness t (tgraphene/graphite, the method we propose has the advantage of being simple and fast, requiring only the acquisition of bright-field images.

  19. Joint denoising and distortion correction of atomic scale scanning transmission electron microscopy images

    OpenAIRE

    Berkels, Benjamin; Wirth, Benedikt

    2016-01-01

    Nowadays, modern electron microscopes deliver images at atomic scale. The precise atomic structure encodes information about material properties. Thus, an important ingredient in the image analysis is to locate the centers of the atoms shown in micrographs as precisely as possible. Here, we consider scanning transmission electron microscopy (STEM), which acquires data in a rastering pattern, pixel by pixel. Due to this rastering combined with the magnification to atomic scale, movements of th...

  20. Transmission electron microscope interfaced with ion accelerators and its application to materials science

    Energy Technology Data Exchange (ETDEWEB)

    Abe, Hiroaki; Naramoto, Hiroshi [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment; Hojou, Kiichi; Furuno, Shigemi; Tsukamoto, Tetsuo

    1997-03-01

    We have developed the transmission/analytical electron microscope interfaced with two sets of ion accelerators (TEM-Accelerators Facility) at JAERI-Takasaki. The facility is expected to provide quantitative insights into radiation effects, such as damage evolution, irradiation-induced phase transformation and their stability, through in-situ observation and analysis under ion and/or electron irradiation. The TEM-Accelerators Facility and its application to materials research are reviewed. (author)

  1. Electron energy loss spectroscopy techniques for the study of microbial chromium(VI) reduction

    Science.gov (United States)

    Daulton, Tyrone L.; Little, Brenda J.; Lowe, Kristine; Jones-Meehan, Joanne

    2002-01-01

    Electron energy loss spectroscopy (EELS) techniques were used to determine oxidation state, at high spatial resolution, of chromium associated with the metal-reducing bacteria, Shewanella oneidensis, in anaerobic cultures containing Cr(VI)O4(2-). These techniques were applied to fixed cells examined in thin section by conventional transmission electron microscopy (TEM) as well as unfixed, hydrated bacteria examined by environmental cell (EC)-TEM. Two distinct populations of bacteria were observed by TEM: bacteria exhibiting low image contrast and bacteria exhibiting high contrast in their cell membrane (or boundary) structure which was often encrusted with high-contrast precipitates. Measurements by EELS demonstrated that cell boundaries became saturated with low concentrations of Cr and the precipitates encrusting bacterial cells contained a reduced form of Cr in oxidation state + 3 or lower.

  2. Transport of electrons in lead oxide studied by CELIV technique

    Science.gov (United States)

    Semeniuk, O.; Juska, G.; Oelerich, J. O.; Jandieri, K.; Baranovskii, S. D.; Reznik, A.

    2017-01-01

    Although polycrystalline lead oxide (PbO) has a long history of application in optoelectronics and imaging, the transport mechanism for electrons in this material has not yet been clarified. Using the photo-generated charge extraction by linear increasing voltage (photo-CELIV) technique, we provide the temperature- and field-dependences of electron mobility in poly-PbO. It is found that electrons undergo dispersive transport, i.e. their mobility decreases in the course of time. Multiple trapping of electrons from the conduction band into the developed band tail is revealed as the dominant transport mechanism. This differs dramatically from the dispersive transport of holes in the same material, dominated by topological factors and not by energy disorder.

  3. In-situ transmission electron microscopy observation of electromigration in Au thin wires.

    Science.gov (United States)

    Murakami, Yosuke; Arita, Masashi; Hamada, Kouichi; Takahashi, Yasuo

    2012-11-01

    Electromigration of thin Au wire is studied by the use of in-situ transmission electron microscopy (TEM) techniques from the viewpoint of nanogap formation. We use a relatively wide Au wire as a starting material because the position-dependent structure change in the wire provides information of the thermal effect caused by the current flow. In-situ TEM observation, in which current measurements of the Au wire are simultaneously performed, reveals the process of the growth of voids and grains. Finally the formation of a nanogap by electromigration is observed doing with current measurements. All the results observed by in-situ TEM indicate the fact that the thermal effects or temperature increase in the wire region take an important role for the structure change caused by electromigration of Au in the wire. It is suggested that the position of the nanogap can roughly be arranged by setting the wire structure and current direction even though a relatively wide wire was used. The detailed observation by in-situ TEM also suggests that the control of heat generation in the wire makes the nanogap sharp because of the well-controlled recrystallization of Au nanowires.

  4. Applying shot boundary detection for automated crystal growth analysis during in situ transmission electron microscope experiments

    Energy Technology Data Exchange (ETDEWEB)

    Moeglein, W. A.; Griswold, R.; Mehdi, B. L.; Browning, N. D.; Teuton, J.

    2017-01-03

    In-situ (scanning) transmission electron microscopy (S/TEM) is being developed for numerous applications in the study of nucleation and growth under electrochemical driving forces. For this type of experiment, one of the key parameters is to identify when nucleation initiates. Typically the process of identifying the moment that crystals begin to form is a manual process requiring the user to perform an observation and respond accordingly (adjust focus, magnification, translate the stage etc.). However, as the speed of the cameras being used to perform these observations increases, the ability of a user to “catch” the important initial stage of nucleation decreases (there is more information that is available in the first few milliseconds of the process). Here we show that video shot boundary detection (SBD) can automatically detect frames where a change in the image occurs. We show that this method can be applied to quickly and accurately identify points of change during crystal growth. This technique allows for automated segmentation of a digital stream for further analysis and the assignment of arbitrary time stamps for the initiation of processes that are independent of the user’s ability to observe and react.

  5. Fast and accurate marker-based projective registration method for uncalibrated transmission electron microscope tilt series.

    Science.gov (United States)

    Lee, Ho; Lee, Jeongjin; Shin, Yeong Gil; Lee, Rena; Xing, Lei

    2010-06-21

    This paper presents a fast and accurate marker-based automatic registration technique for aligning uncalibrated projections taken from a transmission electron microscope (TEM) with different tilt angles and orientations. Most of the existing TEM image alignment methods estimate the similarity between images using the projection model with least-squares metric and guess alignment parameters by computationally expensive nonlinear optimization schemes. Approaches based on the least-squares metric which is sensitive to outliers may cause misalignment since automatic tracking methods, though reliable, can produce a few incorrect trajectories due to a large number of marker points. To decrease the influence of outliers, we propose a robust similarity measure using the projection model with a Gaussian weighting function. This function is very effective in suppressing outliers that are far from correct trajectories and thus provides a more robust metric. In addition, we suggest a fast search strategy based on the non-gradient Powell's multidimensional optimization scheme to speed up optimization as only meaningful parameters are considered during iterative projection model estimation. Experimental results show that our method brings more accurate alignment with less computational cost compared to conventional automatic alignment methods.

  6. Transmission Electron Microscopy of a CMSX-4 Ni-Base Superalloy Produced by Selective Electron Beam Melting

    Directory of Open Access Journals (Sweden)

    Alireza B. Parsa

    2016-10-01

    Full Text Available In this work, the microstructures of superalloy specimens produced using selective electron beam melting additive manufacturing were characterized. The materials were produced using a CMSX-4 powder. Two selective electron beam melting processing strategies, which result in higher and lower effective cooling rates, are described. Orientation imaging microscopy, scanning transmission electron microscopy and conventional high resolution transmission electron microscopy are used to investigate the microstructures. Our results suggest that selective electron beam melting processing results in near equilibrium microstructures, as far as γ′ volume fractions, the formation of small amounts of TCP phases and the partitioning behavior of the alloy elements are concerned. As expected, higher cooling rates result in smaller dendrite spacings, which are two orders of magnitude smaller than observed during conventional single crystal casting. During processing, columnar grains grow in <100> directions, which are rotated with respect to each other. There are coarse γ/γ′ microstructures in high angle boundary regions. Dislocation networks form low angle boundaries. A striking feature of the as processed selective electron beam melting specimens is their high dislocation density. From a fundamental point of view, this opens new possibilities for the investigation of elementary dislocation processes which accompany solidification.

  7. Cryogenic transmission electron microscopy (cryo-TEM) for studying the morphology of colloidal drug delivery systems

    DEFF Research Database (Denmark)

    Kuntsche, Judith; Horst, Jennifer C; Bunjes, Heike

    2011-01-01

    Cryogenic transmission electron microscopy (cryo-TEM) has evolved into an indispensable tool for the characterization of colloidal drug delivery systems. It can be applied to study the size, shape and internal structure of nanoparticulate carrier systems as well as the overall colloidal composition...

  8. Magnetic imaging with a Zernike-type phase plate in a transmission electron microscope

    DEFF Research Database (Denmark)

    Pollard, Shawn; Malac, Marek; Beleggia, Marco

    2013-01-01

    We demonstrate the use of a hole-free phase plate (HFPP) for magnetic imaging in transmission electron microscopy by mapping the domain structure in PrDyFeB samples. The HFPP, a Zernike-like imaging method, allows for detecting magnetic signals in-focus to correlate the sample crystal structure a...

  9. Advances in Transmission Electron Microscopy : In Situ Straining and In Situ Compression Experiments on Metallic Glasses

    NARCIS (Netherlands)

    De Hosson, Jeff Th. M.

    In the field of transmission electron microscopy (TEM), fundamental and practical reasons still remain that hamper a straightforward correlation between microscopic structural information and deformation mechanisms in materials. In this article, it is argued that one should focus in particular on in

  10. Transmission Electron Microscopy Specimen Preparation Method for Multiphase Porous Functional Ceramics

    DEFF Research Database (Denmark)

    Zhang, Wei; Kuhn, Luise Theil; Jørgensen, Peter Stanley

    2013-01-01

    An optimum method is proposed to prepare thin foil transmission electron microscopy (TEM) lamellae of multiphase porous functional ceramics: prefilling the pore space of these materials with an epoxy resin prior to focused ion beam milling. Several advantages of epoxy impregnation are demonstrate...

  11. Structural dynamics of gas-phase molybdenum nanoclusters : A transmission electron microscopy study

    NARCIS (Netherlands)

    Vystavel, T; Koch, SA; Palasantzas, G; De Hosson, JTM

    2005-01-01

    In this paper we study structural aspects of molybdenum clusters by transmission electron microscopy. The deposited clusters with sizes 4 nm or larger show a body-centered crystal (bcc) structure. The clusters are self-assembled from smaller structural units and form cuboids with a typical size of 4

  12. SPINEL METAL INTERFACES IN LASER COATED STEELS - A TRANSMISSION ELECTRON-MICROSCOPY STUDY

    NARCIS (Netherlands)

    ZHOU, XB; DEHOSSON, JTM

    1991-01-01

    This paper reports on coating a Duplex steel SAF 2205 and stainless steel 304 by bringing a mixture of Cr2O3 and Fe powder into a laser beam. Transmission electron microscopy reveals that in the case of proper bonding between substrate and coating a spinel structure around the composition FeCr2O4 co

  13. Spinel/Metal Interfaces in Laser Coated Steels : A Transmission Electron Microscopy Study

    NARCIS (Netherlands)

    Zhou, X.B.; Hosson, J.Th.M. De

    1991-01-01

    This paper reports on coating a Duplex steel SAF 2205 and stainless steel 304 by bringing a mixture of Cr2O3 and Fe powder into a laser beam. Transmission electron microscopy reveals that in the case of proper bonding between substrate and coating a spinel structure around the composition FeCr2O4 co

  14. Theories and technologies of electronic-electrical-mechanical integrated(EEMI)transmission system

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    @@ EEMI is one of the hot spots in cross-disciplinary research. The research in this topic was to discard the traditional mechanical gear reducer, integrate electrical motor with mechanical load, control the electrical motor by electrical power generated by microelectronics and electrical electronics; namely, form a EEMI transmission system in the mechanical equipments with low rotation rate and large rotation torque.

  15. Observation of microporous cesium salts of 12-tungstosilicic acid using scanning transmission electron microscopy.

    Science.gov (United States)

    Hiyoshi, Norihito; Kamiya, Yuichi

    2015-06-21

    Heteropolyanions and their arrays in microporous cesium salts of 12-tungstosilicic acid, Cs2.5H1.5[SiW12O40] and Cs4.0[SiW12O40], were observed by aberration-corrected scanning transmission electron microscopy. Microstructures that form micropores in the polyoxometalates were visualized.

  16. Advances in Transmission Electron Microscopy : Self Healing or is Prevention better than Cure?

    NARCIS (Netherlands)

    Hosson, Jeff Th.M. De; Yasuda, Hiroyuki Y.; Zwaag, S. van der

    2007-01-01

    In the field of transmission electron microscopy fundamental and practical reasons still remain that hamper a straightforward correlation between microscopic structural information and self healing mechanisms in materials. We argue that one should focus in particular on in situ rather than on postmo

  17. Thermal stability of catalytically grown multi-walled carbon nanotubes observed in transmission electron microscopy

    DEFF Research Database (Denmark)

    Wang, Cheng-Yu; Liu, Chuan-Pu; Boothroyd, Chris

    2009-01-01

    The thermal stability of multi-walled carbon nanotubes (MWCNTs) was assessed in situ by transmission electron microscopy. Upon heating, Ni catalysts in MWC-NTs containing bamboo structures shrank from the tail due to evaporation, leading to additional bamboo formation and tube elongation at 800...

  18. 77 FR 50932 - Electronic Transmission of Customs Data-Outbound International Letter-Post Items

    Science.gov (United States)

    2012-08-23

    ... 20 Electronic Transmission of Customs Data--Outbound International Letter-Post Items AGENCY: Postal... Standards of the United States Postal Service, International Mail Manual (IMM ) to require that customs data... Service and other federal agencies to ensure mailers' compliance with federal export...

  19. Current status and future directions for in situ transmission electron microscopy

    DEFF Research Database (Denmark)

    Taheri, Mitra L.; Stach, Eric A.; Arslan, Ilke

    2016-01-01

    This review article discusses the current and future possibilities for the application of in situ transmission electron microscopy to reveal synthesis pathways and functional mechanisms in complex and nanoscale materials. The findings of a group of scientists, representing academia, government labs...

  20. Transmission Electron Microscopy Study of Individual Carbon Nanotube Breakdown Caused by Joule Heating in Air

    DEFF Research Database (Denmark)

    Mølhave, Kristian; Gudnason, S.B.; Pedersen, Anders Tegtmeier

    2006-01-01

    We present repeated structural and electrical measurements on individual multiwalled carbon nanotubes, alternating between electrical measurements under ambient conditions and transmission electron microscopy (TEM). The multiwalled carbon nanotubes made by chemical vapor deposition were manipulated...... conductors with remarkably predictable electrical properties despite extensive structural damage....

  1. Light-Induced Reduction of Cuprous Oxide in an Environmental Transmission Electron Microscope

    DEFF Research Database (Denmark)

    Cavalca, Filippo Carlo; Laursen, Anders Bo; Wagner, Jakob Birkedal

    2013-01-01

    . Environmental transmission electron microscopy (ETEM) makes it possible to obtain insight into the local structure, composition and reactivity of catalysts in their working environment, which is of fundamental interest for sustainable energy research and is essential for further material optimization. Herein...

  2. Simulations of the electron cloud buildup and its influence on the microwave transmission measurement

    Energy Technology Data Exchange (ETDEWEB)

    Haas, Oliver Sebastian, E-mail: o.haas@gsi.de [GSI Helmholtzzentrum für Schwerionenforschung GmbH, Planckstraße 1, 64291 Darmstadt (Germany); Boine-Frankenheim, Oliver [GSI Helmholtzzentrum für Schwerionenforschung GmbH, Planckstraße 1, 64291 Darmstadt (Germany); Technische Universität Darmstadt, Institut für Theorie Elektromagnetischer Felder, Schlossgartenstraße 8, 64289 Darmstadt (Germany); Petrov, Fedor [Technische Universität Darmstadt, Institut für Theorie Elektromagnetischer Felder, Schlossgartenstraße 8, 64289 Darmstadt (Germany)

    2013-11-21

    An electron cloud density in an accelerator can be measured using the Microwave Transmission (MWT) method. The aim of our study is to evaluate the influence of a realistic, nonuniform electron cloud on the MWT. We conduct electron cloud buildup simulations for beam pipe geometries and bunch parameters resembling roughly the conditions in the CERN SPS. For different microwave waveguide modes the phase shift induced by a known electron cloud density is obtained from three different approaches: 3D Particle-In-Cell (PIC) simulation of the electron response, a 2D eigenvalue solver for waveguide modes assuming a dielectric response function for cold electrons, a perturbative method assuming a sufficiently smooth density profile. While several electron cloud parameters, such as temperature, result in minor errors in the determined density, the transversely inhomogeneous density can introduce a large error in the measured electron density. We show that the perturbative approach is sufficient to describe the phase shift under realistic electron cloud conditions. Depending on the geometry of the beam pipe, the external magnetic field configuration and the used waveguide mode, the electron cloud density can be concentrated at the beam pipe or near the beam pipe center, leading to a severe over- or underestimation of the electron density. -- Author-Highlights: •Electron cloud distributions are very inhomogeneous, especially in dipoles. •These inhomogeneities affect the microwave transmission measurement results. •Electron density might be over- or underestimated, depending on setup. •This can be quantified with several models, e.g. a perturbative approach.

  3. Whole-cell imaging of the budding yeast Saccharomyces cerevisiae by high-voltage scanning transmission electron tomography

    Energy Technology Data Exchange (ETDEWEB)

    Murata, Kazuyoshi, E-mail: kazum@nips.ac.jp [National Institute for Physiological Sciences, Okazaki, Aichi 444-8585 (Japan); Esaki, Masatoshi; Ogura, Teru [Institute of Molecular Embryology and Genetics, Kumamoto University, Kumamoto 860-0811 (Japan); Arai, Shigeo; Yamamoto, Yuta; Tanaka, Nobuo [Ecotopia Science Institute, Nagoya University, Nagoya, Aichi 464-8603 (Japan)

    2014-11-15

    Electron tomography using a high-voltage electron microscope (HVEM) provides three-dimensional information about cellular components in sections thicker than 1 μm, although in bright-field mode image degradation caused by multiple inelastic scattering of transmitted electrons limit the attainable resolution. Scanning transmission electron microscopy (STEM) is believed to give enhanced contrast and resolution compared to conventional transmission electron microscopy (CTEM). Samples up to 1 μm in thickness have been analyzed with an intermediate-voltage electron microscope because inelastic scattering is not a critical limitation, and probe broadening can be minimized. Here, we employed STEM at 1 MeV high-voltage to extend the useful specimen thickness for electron tomography, which we demonstrate by a seamless tomographic reconstruction of a whole, budding Saccharomyces cerevisiae yeast cell, which is ∼3 μm in thickness. High-voltage STEM tomography, especially in the bright-field mode, demonstrated sufficiently enhanced contrast and intensity, compared to CTEM tomography, to permit segmentation of major organelles in the whole cell. STEM imaging also reduced specimen shrinkage during tilt-series acquisition. The fidelity of structural preservation was limited by cytoplasmic extraction, and the spatial resolution was limited by the relatively large convergence angle of the scanning probe. However, the new technique has potential to solve longstanding problems of image blurring in biological specimens beyond 1 μm in thickness, and may facilitate new research in cellular structural biology. - Highlights: • High voltage TEM and STEM tomography were compared to visualize whole yeast cells. • 1-MeV STEM-BF tomography had significant improvements in image contrast and SNR. • 1-MeV STEM tomography showed less specimen shrinkage than the TEM tomography. • KMnO{sub 4} post-treatment permitted segmenting the major cellular components.

  4. Method and apparatus for a high-resolution three dimensional confocal scanning transmission electron microscope

    Science.gov (United States)

    de Jonge, Niels [Oak Ridge, TN

    2010-08-17

    A confocal scanning transmission electron microscope which includes an electron illumination device providing an incident electron beam propagating in a direction defining a propagation axis, and a precision specimen scanning stage positioned along the propagation axis and movable in at least one direction transverse to the propagation axis. The precision specimen scanning stage is configured for positioning a specimen relative to the incident electron beam. A projector lens receives a transmitted electron beam transmitted through at least part of the specimen and focuses this transmitted beam onto an image plane, where the transmitted beam results from the specimen being illuminated by the incident electron beam. A detection system is placed approximately in the image plane.

  5. Dynamic Simulations of Combined Transmission and Distribution Systems using Parallel Processing Techniques

    OpenAIRE

    Aristidou, P; Van Cutsem, T

    2014-01-01

    Simulating a power system with both transmission and distribution networks modeled in detail is a huge computational challenge. In this paper, we propose a Schur-complement-based domain decomposition algorithm to provide accurate, detailed dynamic simulations of the combined system. The simulation procedure is accelerated with the use of parallel programming techniques, taking advantage of the parallelization opportunities inherent in domain decomposition algorithms. The proposed algorithm is...

  6. Data processing techniques for a wireless data transmission application via mud

    OpenAIRE

    Zhao Qingjie; Zhang Baojun; Wang Wei

    2011-01-01

    Abstract The data measured by well bottom sensors can be transmitted to the surface through the drilling mud during oil drilling operations. This article introduces a data processing scheme for a wireless data transmission application via mud. The detailed signal processing procedure is given, and several data processing techniques used are discussed, mainly including data encoding and signal integrating method, signal filtering, data storage and manage method, peak detection, signal recognit...

  7. Testing aspects of advanced coherent electron cooling technique

    Energy Technology Data Exchange (ETDEWEB)

    Litvinenko, V.; Jing, Y.; Pinayev, I.; Wang, G.; Samulyak, R.; Ratner, D.

    2015-05-03

    An advanced version of the Coherent-electron Cooling (CeC) based on the micro-bunching instability was proposed. This approach promises significant increase in the bandwidth of the CeC system and, therefore, significant shortening of cooling time in high-energy hadron colliders. In this paper we present our plans of simulating and testing the key aspects of this proposed technique using the set-up of the coherent-electron-cooling proof-of-principle experiment at BNL.

  8. A review of transmission electron microscopes with in situ ion irradiation

    Science.gov (United States)

    Hinks, J. A.

    2009-12-01

    Transmission electron microscopy (TEM) with in situ ion irradiation is unique amongst experimental techniques in allowing the direct observation of the internal microstructure of materials on the nanoscale whilst they are being subjected to bombardment with energetic particles. Invaluable insights into the underlying atomistic processes at work can be gained through direct investigation of radiation induced and enhanced effects such as: phase changes and segregation; mechanical and structural changes; atomic/layer mixing and chemical disorder; compositional changes; chemical reactions; grain growth and shrinkage; precipitation and dissolution; defect/bubble formation, growth, motion, coalescence, removal and destruction; ionisation; diffusion; and collision cascades. The experimental results obtained can be used to validate the predictions of computational models which in turn can elucidate the mechanisms behind the phenomena seen in the microscope. It is 50 years since the first TEM observations of in situ ion irradiation were made by D.W. Pashley, A.E.B. Presland and J.W. Menter at the Tube Investment Laboratories in Cambridge, United Kingdom and 40 years since the first interfacing of an ion beam system with a TEM by P.A. Thackery, R.S. Nelson and H.C. Sansom at the Atomic Energy Research Establishment at Harwell, United Kingdom. In that time the field has grown with references in the literature to around thirty examples of such facilities. This paper gives an overview of the importance of the technique, especially with regard to the current challenges faced in understanding radiation damage in nuclear environments; a description of some of the important construction elements and design considerations of TEMs with in situ ion irradiation; a brief history of the development of this type of instrument; a summary of the facilities built around the world over the last half century; and finally a focus on the instruments in operation today.

  9. A review of transmission electron microscopes with in situ ion irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Hinks, J.A., E-mail: j.a.hinks@salford.ac.u [Centre for Functional Materials, University of Salford, Salford M5 4WT (United Kingdom)

    2009-12-15

    Transmission electron microscopy (TEM) with in situ ion irradiation is unique amongst experimental techniques in allowing the direct observation of the internal microstructure of materials on the nanoscale whilst they are being subjected to bombardment with energetic particles. Invaluable insights into the underlying atomistic processes at work can be gained through direct investigation of radiation induced and enhanced effects such as: phase changes and segregation; mechanical and structural changes; atomic/layer mixing and chemical disorder; compositional changes; chemical reactions; grain growth and shrinkage; precipitation and dissolution; defect/bubble formation, growth, motion, coalescence, removal and destruction; ionisation; diffusion; and collision cascades. The experimental results obtained can be used to validate the predictions of computational models which in turn can elucidate the mechanisms behind the phenomena seen in the microscope. It is 50 years since the first TEM observations of in situ ion irradiation were made by D.W. Pashley, A.E.B. Presland and J.W. Menter at the Tube Investment Laboratories in Cambridge, United Kingdom and 40 years since the first interfacing of an ion beam system with a TEM by P.A. Thackery, R.S. Nelson and H.C. Sansom at the Atomic Energy Research Establishment at Harwell, United Kingdom. In that time the field has grown with references in the literature to around thirty examples of such facilities. This paper gives an overview of the importance of the technique, especially with regard to the current challenges faced in understanding radiation damage in nuclear environments; a description of some of the important construction elements and design considerations of TEMs with in situ ion irradiation; a brief history of the development of this type of instrument; a summary of the facilities built around the world over the last half century; and finally a focus on the instruments in operation today.

  10. Nanoscale chromatin structure characterization for optical applications: a transmission electron microscopy study (Conference Presentation)

    Science.gov (United States)

    Li, Yue; Cherkezyan, Lusik; Zhang, Di; Almassalha, Luay; Roth, Eric; Chandler, John; Bleher, Reiner; Subramanian, Hariharan; Dravid, Vinayak P.; Backman, Vadim

    2017-02-01

    Structural and biological origins of light scattering in cells and tissue are still poorly understood. We demonstrate how this problem might be addressed through the use of transmission electron microscopy (TEM). For biological samples, TEM image intensity is proportional to mass-density, and thus proportional to refractive index (RI). By calculating the autocorrelation function (ACF) of TEM image intensity of a thin-section of cells, we essentially maintain the nanoscale ACF of the 3D cellular RI distribution, given that the RI distribution is statistically isotropic. Using this nanoscale 3D RI ACF, we can simulate light scattering through biological samples, and thus guiding many optical techniques to quantify specific structures. In this work, we chose to use Partial Wave Spectroscopy (PWS) microscopy as a one of the nanoscale-sensitive optical techniques. Hela cells were prepared using standard protocol to preserve nanoscale ultrastructure, and a 50-nm slice was sectioned for TEM imaging at 6 nm resolution. The ACF was calculated for chromatin, and the PWS mean sigma was calculated by summing over the power spectral density in the visible light frequency of a random medium generated to match the ACF. A 1-µm slice adjacent to the 50-nm slice was sectioned for PWS measurement to guarantee identical chromatin structure. For 33 cells, we compared the calculated PWS mean sigma from TEM and the value measured directly, and obtained a strong correlation of 0.69. This example indicates the great potential of using TEM measured RI distribution to better understand the quantification of cellular nanostructure by optical methods.

  11. Core size determination and structural characterization of intravenous iron complexes by cryogenic transmission electron microscopy.

    Science.gov (United States)

    Wu, Yong; Petrochenko, Peter; Chen, Lynn; Wong, Sook Yee; Absar, Mohammad; Choi, Stephanie; Zheng, Jiwen

    2016-05-30

    Understanding physicochemical properties of intravenous (IV) iron drug products is essential to ensure the manufacturing process is consistent and streamlined. The history of physicochemical characterization of IV iron complex formulations stretches over several decades, with disparities in iron core size and particle morphology as the major source of debate. One of the main reasons for this controversy is room temperature sample preparation artifacts, which affect accurate determination of size, shape and agglomeration/aggregation of nanoscale iron particles. The present study is first to report the ultra-fine iron core structures of four IV iron complex formulations, sodium ferric gluconate, iron sucrose, low molecular weight iron dextran and ferumoxytol, using a cryogenic transmission electron microscopy (cryo-TEM) preservation technique, as opposed to the conventional room temperature (RT-TEM) technique. Our results show that room temperature preparation causes nanoparticle aggregation and deformation, while cryo-TEM preserves IV iron colloidal suspension in their native frozen-hydrated and undiluted state. In contrast to the current consensus in literature, all four IV iron colloids exhibit a similar morphology of their iron oxide cores with a spherical shape, narrow size distribution and an average size of 2nm. Moreover, out of the four tested formulations, ferumoxytol exhibits a cluster-like community of several iron carbohydrate particles which likely accounts for its large hydrodynamic size of 25nm, measured with dynamic light scattering. Our findings outline a suitable method for identifying colloidal nanoparticle core size in the native state, which is increasingly important for manufacturing and design control of complex drug formulations, such as IV iron drug products.

  12. DSP-based optical modulation technique for long-haul transmission

    Science.gov (United States)

    Yoshida, T.; Sugihara, T.; Uto, K.

    2015-01-01

    Fiber nonlinearity and equalization-enhanced phase noise (EEPN) generate rapid perturbations and critically limit the system capacity and range of long-haul optical transmission. It is possible to cancel the rapid perturbations by introducing a particular correlation between multiple signals at the transmitter and analyzing the received signals using digital signal processing. In this paper, we review our proposed techniques to cancel rapid perturbations of polarization multiplexed signals due to fiber nonlinearity and EEPN. Numerical simulation of quaternary phase-shift keying based signals shows 1.2 dB and 0.5 dB improvement respectively from the proposed cancellation techniques for fiber nonlinearity and EEPN.

  13. Direct detection in Transmission Electron Microscopy with a 5{mu}m pitch CMOS pixel sensor

    Energy Technology Data Exchange (ETDEWEB)

    Contarato, Devis, E-mail: DContarato@lbl.go [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Denes, Peter; Doering, Dionisio; Joseph, John; Krieger, Brad [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States)

    2011-04-11

    This paper presents the characterization of a CMOS monolithic pixel sensor prototype optimized for direct detection in Transmission Electron Microscopy (TEM). The sensor was manufactured in a deep-submicron commercial CMOS process and features pixels of 5{mu}m pitch. Different pixel architectures have been implemented in the test chip, and the best performing architecture has been selected from a series of tests performed with 300 keV electrons. Irradiation tests to high electron doses have also been performed in order to estimate device lifetime.

  14. Acquisition parameters optimization of a transmission electron forward scatter diffraction system in a cold-field emission scanning electron microscope for nanomaterials characterization.

    Science.gov (United States)

    Brodusch, Nicolas; Demers, Hendrix; Trudeau, Michel; Gauvin, Raynald

    2013-01-01

    Transmission electron forward scatter diffraction (t-EFSD) is a new technique providing crystallographic information with high resolution on thin specimens by using a conventional electron backscatter diffraction (EBSD) system in a scanning electron microscope. In this study, the impact of tilt angle, working distance, and detector distance on the Kikuchi pattern quality were investigated in a cold-field emission scanning electron microscope (CFE-SEM). We demonstrated that t-EFSD is applicable for tilt angles ranging from -20° to -40°. Working distance (WD) should be optimized for each material by choosing the WD for which the EBSD camera screen illumination is the highest, as the number of detected electrons on the screen is directly dependent on the scattering angle. To take advantage of the best performances of the CFE-SEM, the EBSD camera should be close to the sample and oriented towards the bottom to increase forward scattered electron collection efficiency. However, specimen chamber cluttering and beam/mechanical drift are important limitations in the CFE-SEM used in this work. Finally, the importance of t-EFSD in materials science characterization was illustrated through three examples of phase identification and orientation mapping. © Wiley Periodicals, Inc.

  15. Development of a novel straining holder for transmission electron microscopy compatible with single tilt-axis electron tomography.

    Science.gov (United States)

    Sato, K; Miyazaki, H; Gondo, T; Miyazaki, S; Murayama, M; Hata, S

    2015-10-01

    We have developed a newly designed straining specimen holder for in situ transmission electron microscopy (TEM) compatible with high-angle single tilt-axis electron tomography. The holder can deform a TEM specimen under tensile stress with the strain rate between 1.5 × 10(-6) and 5.2 × 10(-3) s(-1). We have also confirmed that the maximum tilt angle of the specimen holder reaches ±60° with a rectangular shape aluminum specimen. The new specimen holder, termed as 'straining and tomography holder', will have wide range potential applications in materials science.

  16. Ultrafast transmission electron microscopy using a laser-driven field emitter: femtosecond resolution with a high coherence electron beam

    CERN Document Server

    Feist, Armin; da Silva, Nara Rubiano; Danz, Thomas; Möller, Marcel; Priebe, Katharina E; Domröse, Till; Gatzmann, J Gregor; Rost, Stefan; Schauss, Jakob; Strauch, Stefanie; Bormann, Reiner; Sivis, Murat; Schäfer, Sascha; Ropers, Claus

    2016-01-01

    We present the development of the first ultrafast transmission electron microscope (UTEM) driven by localized photoemission from a field emitter cathode. We describe the implementation of the instrument, the photoemitter concept and the quantitative electron beam parameters achieved. Establishing a new source for ultrafast TEM, the G\\"ottingen UTEM employs nano-localized linear photoemission from a Schottky emitter, which enables operation with freely tunable temporal structure, from continuous wave to femtosecond pulsed mode. Using this emission mechanism, we achieve record pulse properties in ultrafast electron microscopy of 9 {\\AA} focused beam diameter, 200 fs pulse duration and 0.6 eV energy width. We illustrate the possibility to conduct ultrafast imaging, diffraction, holography and spectroscopy with this instrument and also discuss opportunities to harness quantum coherent interactions between intense laser fields and free electron beams.

  17. Zinc deficiency in the 11 day rat embryo: a scanning and transmission electron microscope study

    Energy Technology Data Exchange (ETDEWEB)

    Harding, A.J.; Dreosti, I.E.; Tulsi, R.S.

    1988-01-01

    Zinc deficient rat embryos were obtained on the 11th day of pregnancy and examined by scanning and transmission electron microscopy. Scanning electron microscopy revealed an increase in the number of deformed embryos, as well as embryonic growth retardation. In addition, the epithelium of zinc deficient embryos displayed a marked increase in surface microvilli, as well as the presence of blebbing. Transmission electron microscopy indicated extensive cell death in the neural epithelium which was apparently more severely damaged by zinc deficiency than were mesenchymal cells. Mitochondrial cristae were affected to a greater degree than any other membrane of the cell and cristael disintegration appeared to represent the principal cellular lesion preceding necrosis of neural cells and neural tube teratology. 29 references, 4 figures, 1 table.

  18. Three-dimensional optical transfer functions in the aberration-corrected scanning transmission electron microscope.

    Science.gov (United States)

    Jones, L; Nellist, P D

    2014-05-01

    In the scanning transmission electron microscope, hardware aberration correctors can now correct for the positive spherical aberration of round electron lenses. These correctors make use of nonround optics such as hexapoles or octupoles, leading to the limiting aberrations often being of a nonround type. Here we explore the effect of a number of potential limiting aberrations on the imaging performance of the scanning transmission electron microscope through their resulting optical transfer functions. In particular, the response of the optical transfer function to changes in defocus are examined, given that this is the final aberration to be tuned just before image acquisition. The resulting three-dimensional optical transfer functions also allow an assessment of the performance of a system for focal-series experiments or optical sectioning applications. © 2014 The Authors Journal of Microscopy © 2014 Royal Microscopical Society.

  19. Four-Dimensional Ultrafast Electron Microscopy: Insights into an Emerging Technique

    KAUST Repository

    Adhikari, Aniruddha

    2016-12-15

    Four-dimensional ultrafast electron microscopy (4D-UEM) is a novel analytical technique that aims to fulfill the long-held dream of researchers to investigate materials at extremely short spatial and temporal resolutions by integrating the excellent spatial resolution of electron microscopes with the temporal resolution of ultrafast femtosecond laser-based spectroscopy. The ingenious use of pulsed photoelectrons to probe surfaces and volumes of materials enables time-resolved snapshots of the dynamics to be captured in a way hitherto impossible by other conventional techniques. The flexibility of 4D-UEM lies in the fact that it can be used in both the scanning (S-UEM) and transmission (UEM) modes depending upon the type of electron microscope involved. While UEM can be employed to monitor elementary structural changes and phase transitions in samples using real-space mapping, diffraction, electron energy-loss spectroscopy, and tomography, S-UEM is well suited to map ultrafast dynamical events on materials surfaces in space and time. This review provides an overview of the unique features that distinguish these techniques and also illustrates the applications of both S-UEM and UEM to a multitude of problems relevant to materials science and chemistry.

  20. Four-Dimensional Ultrafast Electron Microscopy: Insights into an Emerging Technique.

    Science.gov (United States)

    Adhikari, Aniruddha; Eliason, Jeffrey K; Sun, Jingya; Bose, Riya; Flannigan, David J; Mohammed, Omar F

    2017-01-11

    Four-dimensional ultrafast electron microscopy (4D-UEM) is a novel analytical technique that aims to fulfill the long-held dream of researchers to investigate materials at extremely short spatial and temporal resolutions by integrating the excellent spatial resolution of electron microscopes with the temporal resolution of ultrafast femtosecond laser-based spectroscopy. The ingenious use of pulsed photoelectrons to probe surfaces and volumes of materials enables time-resolved snapshots of the dynamics to be captured in a way hitherto impossible by other conventional techniques. The flexibility of 4D-UEM lies in the fact that it can be used in both the scanning (S-UEM) and transmission (UEM) modes depending upon the type of electron microscope involved. While UEM can be employed to monitor elementary structural changes and phase transitions in samples using real-space mapping, diffraction, electron energy-loss spectroscopy, and tomography, S-UEM is well suited to map ultrafast dynamical events on materials surfaces in space and time. This review provides an overview of the unique features that distinguish these techniques and also illustrates the applications of both S-UEM and UEM to a multitude of problems relevant to materials science and chemistry.

  1. Power electronic converters PWM strategies and current control techniques

    CERN Document Server

    Monmasson, Eric

    2013-01-01

    A voltage converter changes the voltage of an electrical power source and is usually combined with other components to create a power supply. This title is devoted to the control of static converters, which deals with pulse-width modulation (PWM) techniques, and also discusses methods for current control. Various application cases are treated. The book is ideal for professionals in power engineering, power electronics, and electric drives industries, as well as practicing engineers, university professors, postdoctoral fellows, and graduate students.

  2. A Second Look at Neutron Resonance Transmission Analysis as a Spent Fuel NDA Technique

    Energy Technology Data Exchange (ETDEWEB)

    James W .Sterbentz; David L. Chichester

    2011-07-01

    Many different nondestructive analysis techniques are currently being investigated as a part of the United States Department of Energy's Next Generation Safeguards Initiative (NGSI) seeking methods to quantify plutonium in spent fuel. Neutron Resonance Transmission Analysis (NRTA) is one of these techniques. Having first been explored in the mid-1970s for the analysis of individual spent-fuel pins a second look, using advanced simulation and modeling methods, is now underway to investigate the suitability of the NRTA technique for assaying complete spent nuclear fuel assemblies. The technique is similar to neutron time-of-flight methods used for cross-section determinations but operates over only the narrow 0.1-20 eV range where strong, distinguishable resonances exist for both the plutonium (239, 240, 241,242Pu) and uranium (235,236,238U) isotopes of interest in spent fuel. Additionally, in this energy range resonances exists for six important fission products (99Tc, 103Rh, 131Xe, 133Cs, 145Nd, and 152Sm) which provide additional information to support spent fuel plutonium assay determinations. Initial modeling shows excellent agreement with previously published experimental data for measurements of individual spent-fuel pins where plutonium assays were demonstrated to have a precision of 2-4%. Within the simulation and modeling analyses of this project scoping studies have explored fourteen different aspects of the technique including the neutron source, drift tube configurations, and gross neutron transmission as well as the impacts of fuel burn up, cooling time, and fission-product interferences. These results show that NRTA may be a very capable experimental technique for spent-fuel assay measurements. The results suggest sufficient transmission strength and signal differentiability is possible for assays through up to 8 pins. For an 8-pin assay (looking at an assembly diagonally), 64% of the pins in a typical 17 ? 17 array of a pressurized water reactor

  3. Evaluation of laser welding techniques for hydrogen transmission. Final report, September 1977-November 1979

    Energy Technology Data Exchange (ETDEWEB)

    Mucci, J

    1980-05-01

    This program was established to determine the feasibility of laser beam welding as a fabrication method for hydrogen transmission and is a precursor in the effort to systematically provide the technological base necessary for large-scale, economic pipeline transmission of fuel for a hydrogen energy system. The study contributes to the technology base by establishing the effect of conventional weld processes and laser beam welding on the mechanical properties of two classes of steels in an air and high pressure gaseous hydrogen environment. Screening evaluation of the tensile, low-cycle fatigue and fracture toughness properties and metallurgical analyses provide the basis for concluding that laser beam welding of AISI 304L stainless steel and ASTM A106B carbon steel can produce weldments of comparable quality to those produced by gas-tungsten arc and electron beam welding and is at least equally compatible with 13.8 MPa (2000 psig) gaseous hydrogen environment.

  4. 31 CFR 363.18 - Is Public Debt liable if the electronic transmission of my data is intercepted?

    Science.gov (United States)

    2010-07-01

    ... Securities Held in TreasuryDirect § 363.18 Is Public Debt liable if the electronic transmission of my data is... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Is Public Debt liable if the electronic transmission of my data is intercepted? 363.18 Section 363.18 Money and Finance:...

  5. Single-shot MeV transmission electron microscopy with picosecond temporal resolution

    CERN Document Server

    Li, R K

    2014-01-01

    Pushing the limits in temporal resolution for transmission electron microscopy (TEM) requires a revolutionary change in the electron source technology. In this paper we study the possibility of employing a radiofrequency photoinjector as the electron source for a time-resolved TEM. By raising the beam energy to the relativistic regime we minimize the space charge effects which otherwise limit the spatio-temporal resolution of the instrument. Analysis and optimization of the system taking into account the achievable beam brightness, electron flux on the sample, chromatic and spherical aberration of the electron optic system, and space charge effects in image formation are presented and supported by detailed numerical modeling. The results demonstrate the feasibility of 10 nanometer - 10 picosecond spatio-temporal resolution single-shot MeV TEM.

  6. A Novel Congestion Avoidance Technique for Simultaneous Real-Time Medical Data Transmission.

    Science.gov (United States)

    Yaakob, Naimah; Khalil, Ibrahim

    2016-03-01

    The use of wireless body sensor networks (WBSN) in medical services aims at providing continuous monitoring of patients' physiological data. However, the scarce resources in WBSN nodes limit their capabilities to cope with massive traffic during multiple, simultaneous data transmissions. This will create a high tendency for congestion, causing severe performance degradation. Congestion may lead to high number of packet loss and unbounded delay which are critical and may lead to wrong diagnosis. This paper, therefore, aims at improving this limitation using a novel congestion avoidance technique to avoid losing real-time and life-critical medical data (e.g., electrocardiogram and electroencephalography) which are vital for diagnosis. The main idea is to integrate the existing rate control scheme of relaxation theory (RT) with a method known as max-min fairness (MMF) to achieve better performance. The MMF can be accomplished using a progressive filling algorithm, which cuts-down excessive sending rates that may overwhelme the limited buffer in WBSN. This paper builds upon our prior study, which provides a preliminary analysis of RT technique in single node. Our current technique integrates the MMF phase to enhance RT performance when the transmission rates exceed certain threshold. Performance evaluation on RT-MMF technique shows remarkable performance improvements, while maintaining the desired quality of service.

  7. DEVELOPMENT OF WIRELESS TECHNIQUES IN DATA AND POWER TRANSMISSION APPLICATION FOR PARTICLE-PHYSICS DETECTORS

    CERN Document Server

    Brenner, R; Dehos, C; De Lurgio, P; Djurcic, Z; Drake, G; Gonzales Gimenez, JL; Gustafsson, L; Kim, DW; Locci, E; Pfeiffer, U; Röhrich, D; Rydberg, D; Schöning, A; Siligaris, A; Soltveit, HK; Ullaland, K; Vincent, P; Vasquez, PR; Wiedner, D; Yang, S

    2017-01-01

    In the WADAPT project described in this Letter of Intent, we propose to develop wireless techniques for data and power transmission in particle-physics detectors. Wireless techniques have developed extremely fast over the last decade and are now mature for being considered as a promising alternative to cables and optical links that would revolutionize the detector design. The WADAPT consortium has been formed to identify the specific needs of different projects that might benefit from wireless techniques with the objective of providing a common platform for research and development in order to optimize effectiveness and cost. The proposed R&D will aim at designing and testing wireless demonstrators for large instrumentation systems.

  8. Laser transmission welding of Clearweld-coated polyethylene glycol terephthalate by incremental scanning technique

    Science.gov (United States)

    Wang, Y. Y.; Wang, A. H.; Weng, Z. K.; Xia, H. B.

    2016-06-01

    Transmission laser welding using Incremental Scanning Technique(TWIST) mode and conventional contour welding mode were adopted to investigate laser transmission welding of 0.5 mm thick PET plate. A 1064 nm fiber laser was used to weld PET at the (TWIST) mode, and an 808 nm diode laser was applied to conduct the conventional contour welding. The Clearweld coating was used as laser absorbing material. The influences of laser parameters (i.e. defocusing distance, distance between two circles) on the quality of weld seams were analyzed by optical microscopy. Moreover, geometry and shear strength of the weld zone were tested to optimize laser parameters. Additionally, the water vapor permeability (WVP) of weld seams was measured to test hermetical capacity. Results show that the shear strength and hermetic capacity of weld seam by TWIST mode are at the same level in comparison with that of the conventional contour welding.

  9. Review of Different Techniques used for Wireless Transmission of Electrical Energy

    Directory of Open Access Journals (Sweden)

    Sarwar Muhammad Bilal

    2016-01-01

    Full Text Available The wireless transfer of electricity has gained vast importance in recent years. Many attempts had been done in this regard. The information generated is quite scattered and distributed. There is a need to harmonize the research findings of various researchers in an adept way. This review paper presents the critical evaluation of the research works done in the field of wireless power transmission since 1891. The attempt has been done in a cohesive way to connect the various findings and discussing their capabilities and limitations. The paper also highlights the major challenges faced by the research area and the new area of applications. The study closes with a conclusive review of latest scientific techniques and theoretical concepts, currently prevalent in wireless power transmission.

  10. In situ transmission electron microscopy investigation of the structural changes in carbon nanotubes during electron emission at high currents

    Energy Technology Data Exchange (ETDEWEB)

    Doytcheva, Maya [Philips Research, Professor Holstlaan 4, 5656 AA Eindhovene (Netherlands); Kaiser, Monja [Philips Research, Professor Holstlaan 4, 5656 AA Eindhoven (Netherlands); Jonge, Niels de [Oak Ridge National Laboratory, 1 Bethel Valley Road, Oak Ridge, TN 37831-6030 (United States)

    2006-07-14

    The structural changes in carbon nanotubes under electron emission conditions were investigated in situ in a transmission electron microscope (TEM). The measurements were performed on individually mounted free-standing multi-walled carbon nanotubes (CNTs). It was found that the structure of the carbon nanotubes did not change gradually, as is the case with field emission electron sources made of sharp metal tips. Instead, changes occurred only above a current level of a few microamperes, which was different for each nanotube. Above the threshold current, carbon nanotubes underwent either structural damage, such as shortening and splitting of the apex of the nanotube, or closing of their open cap. The results are discussed on the basis of several models for degradation mechanisms.

  11. In situ Transmission Electron Microscopy Investigation of the Structural Changes in Carbon Nanotubes During Electron Emission at High Currents

    Energy Technology Data Exchange (ETDEWEB)

    Doytcheva, Maya [Philips Research, The Netherlands; Kaiser, Monja [Philips Research, The Netherlands; De Jonge, Niels [ORNL

    2006-01-01

    The structural changes in carbon nanotubes under electron emission conditions were investigated in situ in a transmission electron microscope (TEM). The measurements were performed on individually mounted free-standing multi-walled carbon nanotubes (CNTs). It was found that the structure of the carbon nanotubes did not change gradually, as is the case with field emission electron sources made of sharp metal tips. Instead, changes occurred only above a current level of a few microamperes, which was different for each nanotube. Above the threshold current, carbon nanotubes underwent either structural damage, such as shortening and splitting of the apex of the nanotube, or closing of their open cap. The results are discussed on the basis of several models for degradation mechanisms.

  12. Characterisation of nano-structured titanium and aluminium nitride coatings by indentation, transmission electron microscopy and electron energy loss spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Girleanu, M., E-mail: maria.girleanu@uha.fr [Mecanique, Materiaux et Procedes de Fabrication, LPMT (EA CNRS 4365), Universite de Haute Alsace, 61 rue Albert Camus, F-68093 Mulhouse (France); Pac, M.-J.; Louis, P. [Mecanique, Materiaux et Procedes de Fabrication, LPMT (EA CNRS 4365), Universite de Haute Alsace, 61 rue Albert Camus, F-68093 Mulhouse (France); Ersen, O.; Werckmann, J. [Departement Structures et Interfaces, IPCMS (UMR CNRS 7504), Universite de Strasbourg, 23 rue du Loess, F-67087 Strasbourg (France); Rousselot, C. [Departement Micro Nano Sciences et Systemes, FEMTO-ST (UMR CNRS 6174), Universite de Franche-Comte, BP 71427, F-25211 Montbeliard (France); Tuilier, M.-H. [Mecanique, Materiaux et Procedes de Fabrication, LPMT (EA CNRS 4365), Universite de Haute Alsace, 61 rue Albert Camus, F-68093 Mulhouse (France)

    2011-07-01

    Titanium and aluminium nitride Ti{sub 1-x}Al{sub x}N films deposited by radiofrequency magnetron reactive sputtering onto steel substrate are examined by transmission electron microscopy over all the range of composition (x = 0, 0.5, 0.68, 0.86, 1). The deposition parameters are optimised in order to grow nitride films with low stress over all the composition range. Transmission electron microscopy cross-section images of Vickers indentation prints performed on that set of coatings show the evolution of their damage behaviour as increasing x Al content. Cubic Ti-rich nitrides consist of small grains clustered in rather large columns sliding along each other during indentation. Hexagonal Al-rich films grow in thinner columns which can be bent under the Vickers tip. Indentation tests carried out on TiN and AlN films are simulated using finite element modelling. Particular aspects of shear stresses and displacements in the coating/substrate are investigated. The growth mode and the nanostructure of two typical films, TiN and Ti{sub 0.14}Al{sub 0.86}N, are studied in detail by combining transmission electron microscopy cross-sections and plan views. Electron energy loss spectrum taken across Ti{sub 0.14}Al{sub 0.86}N film suggests that a part of nitrogen atoms is in cubic-like local environment though the lattice symmetry of Al-rich coatings is hexagonal. The poorly crystallised domains containing Ti and N atoms in cubic-like environment are obviously located in grain boundaries and afford protection of the coating against cracking.

  13. Effects of Electron Flow Current Density on Flow Impedance of Magnetically Insulated Transmission Lines

    Institute of Scientific and Technical Information of China (English)

    HE Yong; ZOU Wen-Kang; SONG Sheng-Yi

    2011-01-01

    @@ In modern pulsed power systems, magnetically insulated transmission lines (MITLs) are used to couple power between the driver and the load.The circuit parameters of MITLs are well understood by employing the concept of Sow impedance derived from Maxwell's equations and pressure balance across the flow.However, the electron density in an MITL is always taken as constant in the application of flow impedance.Thus effects of electron flow current density (product of electron density and drift velocity) in an MITL are neglected.We calculate the flow impedances of an MITL and compare them under three classical MITL theories, in which the electron density profile and electron flow current density are different from each other.It is found that the assumption of constant electron density profile in the calculation of the Sow impedance is not always valid.The electron density profile and the electron flow current density have significant effects on flow impedance of the MITL.The details of the electron flow current density and its effects on the operation impedance of the MITL should be addressed more explicitly experiments and theories in the future.

  14. Energy-independent total quantum transmission of electrons through nanodevices with correlated disorder

    Science.gov (United States)

    Novotny, M. A.

    2014-10-01

    In nanostructures with no appreciable scattering, electrons propagate ballistically, and hence have energy-independent total quantum transmission. For an incoming electron of energy E, the probability T (E) of transmission is obtained from the solution of the time-independent Schrödinger equation. Ballistic transport hence corresponds to T (E)=1. We show that there is a wide class of nanostructures with correlated disorder that have T (E)=1 for all propagating modes, even though they can have strong scattering. We call these nanostructures quantum dragons. An exact mathematical mapping for quantum transmission valid for a large class of atomic arrangements is presented within the single-band tight-binding model. Quantum transmission through a nanostructure is exactly mapped onto quantum transmission through a one-dimensional chain. The mapping is applied to carbon nanotubes in the armchair and zigzag configurations, Bethe lattices, conjoined Bethe lattices, Bethe lattices with hopping within each ring, and tubes formed from rectangular and orthorhombic lattices. The mapping shows that tuning tight-binding parameters to particular correlated values gives T (E)=1 for all the systems studied. A quantum dragon has the same electrical conductivity as a ballistic nanodevice, namely, in a four-terminal measurement the electrical resistance is zero, while in a two-terminal measurement for the single-channel case, the electrical conductivity is equal to the conductance quantum G0=2e2/h, where h is Planck's constant and e the electron charge. We find T (E)=1 is ubiquitous but occurs only on particular surfaces in the tight-binding parameter space.

  15. Parallel preparation of plan-view transmission electron microscopy specimens by vapor-phase etching with integrated etch stops

    Energy Technology Data Exchange (ETDEWEB)

    English, Timothy S., E-mail: englisht@stanford.edu [Department of Mechanical Engineering, Stanford University, Stanford, CA 94305 (United States); Provine, J [Department of Mechanical Engineering, Stanford University, Stanford, CA 94305 (United States); Marshall, Ann F.; Koh, Ai Leen [Stanford Nano Shared Facilities, Stanford University, Stanford, CA 94305 (United States); Kenny, Thomas W. [Department of Mechanical Engineering, Stanford University, Stanford, CA 94305 (United States)

    2016-07-15

    Specimen preparation remains a practical challenge in transmission electron microscopy and frequently limits the quality of structural and chemical characterization data obtained. Prevailing methods for thinning of specimens to electron transparency are serial in nature, time consuming, and prone to producing artifacts and specimen failure. This work presents an alternative method for the preparation of plan-view specimens using isotropic vapor-phase etching with integrated etch stops. An ultrathin amorphous etch-stop layer simultaneously serves as an electron transparent support membrane whose thickness is defined by a controlled growth process such as atomic layer deposition with sub-nanometer precision. This approach eliminates the need for mechanical polishing or ion milling to achieve electron transparency, and reduces the occurrence of preparation induced artifacts. Furthermore, multiple specimens from a plurality of samples can be thinned in parallel due to high selectivity of the vapor-phase etching process. These features enable dramatic reductions in preparation time and cost without sacrificing specimen quality and provide advantages over wet etching techniques. Finally, we demonstrate a platform for high-throughput transmission electron microscopy of plan-view specimens by combining the parallel preparation capabilities of vapor-phase etching with wafer-scale micro- and nanofabrication. - Highlights: • Parallel thinning of plan-view specimens enables high-throughput microscopy studies. • The support membrane thickness is controlled with sub-nanometer precision. • No physical etching (polishing, dimpling, or ion milling) is required. • Large area and uniformly thin specimens are suitable for Cs-corrected HRTEM. • Wafer-scale integration enables custom specimens for in situ experiments.

  16. Dynamic studies of catalysts for biofuel synthesis in an Environmental Transmission Electron Microscope

    DEFF Research Database (Denmark)

    Duchstein, Linus Daniel Leonhard; Wu, Qiongxiao; Christensen, Jakob Munkholt

    2011-01-01

    experimentally. Transmission electron microscopy (TEM) is used for microstructural characterization and provides feedback for both theory and synthesis. TEM is a powerful tool for characterizing of catalysts. However, conventional TEM does not provide dynamic information about catalysts in their working state....... We have recently installed an environmental transmission electron microscope (ETEM) equipped with a differential pumping system to confine a controlled flow of gas around the specimen, allowing observation in a gaseous environment (FEI Titan E-cell, monochromated, objective lens aberration corrector...... changes in the specimen. Representative TEM images of a CuSn based catalyst for synthesis of higher alcohols are shown in Figure 1. The CuSn particles are observed to sinter during the reduction leading to a decreased activity of the catalyst. Figure 2 shows the distribution of Co and Mo in a Co/MoS2...

  17. Nanocrystal Phase Identification by Lattice Fringe Fingerprinting from High Resolution Transmission Electron Microscope Images

    Science.gov (United States)

    Bjorge, Ruben; Seipel, Bjoern; Moeck, Peter; Fraundorf, Philip

    2006-05-01

    Lattice fringe fingerprinting is a novel and powerful method of identifying and characterizing nanocrystalline structures or materials based on images from direct space high-resolution transmission electron microscopy (HRTEM). We examine Fourier transformed HRTEM images of nanocrystals in certain orientations (i.e. lattice fringes and cross fringes) in order to obtain a lattice fringe fingerprint plot. Such plots are used to identify a crystalline nanoparticle by comparing the experimental data with data that are derived from a comprehensive database. A lattice fringe fingerprint plot is similar to a classical X-ray powder diffractogram, but an important advantage is that the intersection angles of lattice fringes give us additional information. When transmission electron microscope image acquisition and data interpretation are automated and connected to a comprehensive database (such as our Nano-Crystallography Database, http://nanocrystallography.research.pdx.edu/), fringe fingerprinting will be able to compete with powder X-ray diffraction in identifying unknown nanocrystals on a routine basis.

  18. X-ray and transmission electron microscopy structural characterization of multifunctional Perovskite thin films

    Energy Technology Data Exchange (ETDEWEB)

    Boudard, M., E-mail: Michel.Boudard@grenoble-inp.fr [Laboratoire des Materiaux et du Genie Physique, Grenoble INP, CNRS(UMR 5628), MINATEC, 3 parvis Louis Neel, BP 257, 38016 Grenoble Cedex 1 (France); Girardot, C. [Laboratoire des Materiaux et du Genie Physique, Grenoble INP, CNRS(UMR 5628), MINATEC, 3 parvis Louis Neel, BP 257, 38016 Grenoble Cedex 1 (France); Schneider Electric Industries S.A.S., 37 Quai Paul Louis Merlin, 38050 Grenoble Cedex 9 (France); Ihzaz, N. [Laboratoire des Materiaux et du Genie Physique, Grenoble INP, CNRS(UMR 5628), MINATEC, 3 parvis Louis Neel, BP 257, 38016 Grenoble Cedex 1 (France); Laboratoire de Physico-Chimie des Materiaux, Departement de Physique, Faculte des Sciences de Monastir, 5019 Monastir, Universite de Monastir (Tunisia); Pignard, S.; Rapenne, L.; Roussel, H. [Laboratoire des Materiaux et du Genie Physique, Grenoble INP, CNRS(UMR 5628), MINATEC, 3 parvis Louis Neel, BP 257, 38016 Grenoble Cedex 1 (France); Bartasyte, A. [Laboratoire des Materiaux et du Genie Physique, Grenoble INP, CNRS(UMR 5628), MINATEC, 3 parvis Louis Neel, BP 257, 38016 Grenoble Cedex 1 (France); P2M, Institut Jean Lamour, Nancy Universite, Bd. des Aiguillettes, 54506 Vandoeuvre-ls-Nancy cedex (France)

    2012-05-01

    Different multifunctional (PbTiO{sub 3}, Sm{sub 0.6}Nd{sub 0.4}NiO{sub 3}, NdMnO{sub 3}) thin films were grown by metalorganic chemical vapor deposition (MOCVD) technique on SrTiO{sub 3} and LaAlO{sub 3} substrates. Transmission electron microscopy (TEM) and X-ray diffraction measurements reveal that almost single crystalline thin films can be epitaxially grown on the top of substrates. The relationship between the crystallographic orientation of the films and those of the substrates were determined by reciprocal space mapping and TEM analyses. PbTi03 thin films appear to be under tensile or compressive strain according to the different mismatch of their cell parameter with those of the substrate. Relaxation mechanism as a function of the film thickness arises from coexistence of different type of domains and size and strain effect are analyzed. SmNiO{sub 3} thin films present diffuse scattering strikes and are less well organized when compared to PbTi0{sub 3} thin films. Different domains are observed as well as an additional parasitic phase close to NiO. Its regular distribution can be associated to reduced transport properties. Preliminary observations on NdMnO{sub 3} thin films shows that an amorphous phase is obtained during MOCVD that can be transformed in a single crystalline film by annealing. The films are under tensile or compressive strain according to the different mismatch of their cell parameter with those of the substrate. Magnetic properties are investigated.

  19. Transmission electron microscopy investigations of the CdSe based quantum structures

    Energy Technology Data Exchange (ETDEWEB)

    Roventa, E.

    2006-09-22

    In this work, the structural morphology of the active region of the ZnSe laser diode: quaternary CdZnSSe quantum well or CdSe quantum dots embedded in CdSe/ZnSSe superlattices is investigated using Transmission Electron Microscopy. The conventional as well as high resolution imaging studies indicated that the degradation of the ZnSe laser diodes is connected with the formation of extended defects in the optical active region leading to a local strain relaxation of the quantum well. Furthermore the outdiffusion of Cd from the quantum well occurs predominantly where the defects are located. The chemical composition and ordering phenomena in CdSe/ZnSSe supperlattices were also investigated, employing a series of five-fold structures with different spacer layer thickness and a ten-fold structure. The composition in the CdSe/ZnSSe superlattice was determined to a certain extent using different techniques. Generally, the encountered difficulties regarding the accuracy of the obtained values are correlated with the complexity of the investigated system and with the available experimental methods used. Regarding the alignment of the dots, experimental results support a strain driven ordering process, in which the strain fields from buried dots lead to heterogeneous nucleation conditions for the dots in the subsequently deposited layers. An increased ordering with subsequent stacking of the dot layers is was also found. An anisotropy of the lateral alignment of the CdSe dots was also observed in two different left angle 110 right angle zone axes. The similar plan-view images shows that the preferential alignment of the dots does not follow low-index crystallographic directions. However, it is assumed that this is attributed to the anisotropic elastic strain distribution combined with surface diffusion. (orig.)

  20. Effects of the Magnetic Flux and of the Electron Momentum on the Transmission Amplitude in the Aharonov-Bohm Interferometer

    Science.gov (United States)

    Amaresh Kumar, M. V.; Sahoo, Debendranath

    A characterization of the two-terminal open-ring Aharonov-Bohm interferometer is made by analyzing the phase space plots in the complex transmission amplitude plane. Two types of plots are considered: type 1 plot uses the magnetic flux as the variable parameter and type 2 plot which uses the electron momentum as the variable parameter. In type 1 plot, the trajectory closes upon itself only when the ratio R of the arm lengths (of the interferometer) is a rational fraction, and the shape and the type of the generated flower-like pattern is sensitive to the electron momentum. For momenta corresponding to discrete eigenstates of the perfect ring (i.e., the ring without the leads), the trajectory passes through the origin a certain fixed number of times before closing upon itself, whereas for arbitrary momenta it never passes through the origin. Although the transmission coefficient is periodic in the flux with the elementary flux quantum as the basic period, the phenomenon of electron transmission is shown not to be so when analyzed via the present technique. The periodicity is seen to spread over several flux units whenever R is a rational fraction whereas there is absolutely no periodicity present when R is an irrational number. In type 2 plot, closed trajectories passing through the origin a number of times are seen for R being a rational fraction. The case R = 1 (i.e., a symmetric ring) with zero flux is rather pathological — it presents a closed loop surrounding the origin. For irrational R values, the trajectories never close.

  1. Barrier layers against oxygen transmission on the basis of electron beam cured methacrylated gelatin

    Science.gov (United States)

    Scherzer, Tom

    1997-08-01

    The development of barrier layers against oxygen transmission on the basis of radiation-curable methacrylated gelatin will be reported. The electron beam cured gelatin coatings show an extremely low oxygen permeability and a high resistance against boiling water. Moreover, the methacrylated gelatins possess good adhesion characteristics. Therefore, they are suited as barrier adhesives in laminates for food packaging applications. If substrate foils from biodegradable polymers are used, the development of completely biodegradable packaging materials seems to be possible.

  2. Studying the Kinetics of Crystalline Silicon Nanoparticle Lithiation with In Situ Transmission Electron Microscopy

    KAUST Repository

    McDowell, Matthew T.

    2012-09-04

    In situ transmission electron microscopy (TEM) is used to study the electrochemical lithiation of high-capacity crystalline Si nanoparticles for use in Li-ion battery anodes. The lithiation reaction slows down as it progresses into the particle interior, and analysis suggests that this behavior is due not to diffusion limitation but instead to the influence of mechanical stress on the driving force for reaction. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Transmission electron microscopy study on silicon nitride/stainless steel bonded interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Poza, P. [Departamento de Ciencia e Ingenieria de los Materiales, Universidad Rey Juan Carlos, 28933 Mostoles, Madrid (Spain); Miranzo, P. [Institute of Ceramics and Glass, CSIC, Campus de Cantoblanco, 28049 Madrid (Spain); Osendi, M.I. [Institute of Ceramics and Glass, CSIC, Campus de Cantoblanco, 28049 Madrid (Spain)], E-mail: miosendi@icv.csic.es

    2008-11-28

    The reaction zone of a diffusion bonded Si{sub 3}N{sub 4}/stainlees steel (ss) interface formed at 1100 deg. C was analyzed by transmission electron microscopy and X-ray diffraction (XRD). Besides the formation of various iron silicides, iron nitride and chromium nitride phases detected by XRD, Cr{sub 3}Ni{sub 5}Si{sub 2} crystals were identified at the interface by TEM.

  4. Low-temperature transmission electron microscopy study of superconducting Nb{sub 3}Sn

    Energy Technology Data Exchange (ETDEWEB)

    Schierning, G.; Theissmann, R. [Faculty of Engineering and CeNIDE, University of Duisburg-Essen, Bismarckstr. 81, 47057 Duisburg (Germany); Acet, M. [Experimentalphysik and CeNIDE, University of Duisburg-Essen, Lotharstr. 1, 47057 Duisburg (Germany); Hoelzel, M. [Fachbereich Materialwissenschaften, Technical University of Darmstadt, Petersenstr. 23, 64287 Darmstadt (Germany); FRM-II, Technical University of Munich, 85747 Garching (Germany); Gruendmayer, J.; Zweck, J. [Physics Faculty, University of Regensburg, 93047 Regensburg (Germany)

    2010-08-15

    By low-temperature transmission electron microscopy we have found nanodomains in a polycrystalline Nb{sub 3}Sn sample. We interpret that these nanodomains form due to a tetragonal distortion. Because twinning seems to be a prominent feature of the real structure of many high T{sub c} superconductors, possible interactions between a twinned structure and superconductivity are briefly discussed. (Abstract Copyright [2010], Wiley Periodicals, Inc.)

  5. A Investigation of Radiotherapy Electron Beams Using Monte Carlo Techniques

    Science.gov (United States)

    Ding, George X.

    1995-01-01

    Radiotherapy electron beams are more complicated than photon beams due to variations in the beam production, the scattering of low-energy electrons, and the presence contaminant photons. The detailed knowledge of a radiotherapy beam is essential to an accurate calculation of dose distribution for a treatment planning system. This investigation aims to enhance our understanding of radiotherapy beams by focusing on electron beams used in radiotherapy. It starts with a description of the Monte Carlo simulation code, BEAM, and a detailed simulation of an accelerator head to obtain realistic radiotherapy beams. The simulation covers electron beams from various accelerators, including the NRC research accelerator, the NPL (UK), accelerator, A Varian Clinac 2100C, a Philips SL75-20, a Siemens KD2, an AECL Therac 20, and a Scanditronix MM50. The beam energies range from 4 to 50 MeV. The EGS4 user code, BEAM, is extensively benchmarked against experiment by comparing calculated dose distributions with measured dose distributions in water. The simulated beams are analyzed to obtain the characteristics of various electron beams from a variety of accelerators. The simulated beams are also used as inputs to calculate the following parameters: the mean electron energy, the most probable energy, the energy-range relationships, the depth-scaling factor to convert depths in plastic to water-equivalent depths, the water-to-air stopping-power ratios, and the electron fluence correction factors used to convert dose measured in plastics to dose in water. These parameters are essential for electron beam dosimetry. The results from this study can be applied in cancer clinics to improve the accuracy of the absolute dosimetry. The simulation also provides information about the backscatter into the beam monitor chamber, and predicts the influence on the beam output factors. This investigation presents comprehensive data on the clinical electron beams, and answers many questions which could

  6. Electronic transmission through p-n and n-p-n junctions of graphene

    Energy Technology Data Exchange (ETDEWEB)

    Setare, M R [Department of Science of Bijar, University of Kurdistan, Bijar (Iran, Islamic Republic of); Jahani, D, E-mail: rezakord@ipm.co, E-mail: Dariush110@gmail.co [Department of Physics, Razi University, Kermanshah (Iran, Islamic Republic of)

    2010-06-23

    In this paper, we first evaluate the electronic transmission of Dirac fermions into a p-n junction of gapped graphene and show that the final result depends on the sign of the refractive index, n. We also, by considering the appropriate wavefunctions in the region of the electrostatic potential, show that both transmission and the reflection probability turn out to be positive and less than unity instead of the negative transmission and higher than unity reflection coefficient commonly referred to as the Klein paradox. We then obtain the transmission probability corresponding to a special p-n junction for which there exists a region in which the low energy excitations of graphene acquire a finite mass and, interestingly, find that in this case the transmission is independent of the index of refraction, in contrast with the corresponding result for gapped graphene. We then discuss the validity of the solutions reported in some of the papers cited in this work which, considering the Buettiker formula, turn out to lead to the wrong results for conductivity.

  7. Transmission Electron Microscopy Analysis of Skin Lesions from Sporotrichosis Epidemic in Rio de Janeiro, Brazil

    Science.gov (United States)

    Porto Ferreira, Cassio; Oliveira de Almeida, Ana Cristina; Corte-Real, Suzana

    2015-01-01

    Transmission electron microscopy can yield useful information in a range of scientific fields; it is capable of imaging at a significantly higher resolution than light microscopes and has been a very useful tool in the identification of morphological changes of the dermis as well as assessment of changes in the extracellular matrix. Our aim is to characterize by electron microscopy the cellular profile of lesions caused by Sporothrix schenckii from the sporotrichosis epidemic in its zoonotic form that occurs in Rio de Janeiro, Brazil. PMID:25653392

  8. Magnification variations due to illumination curvature and object defocus in transmission electron microscopy

    Science.gov (United States)

    van Duinen, Gijs; van Heel, Marin; Patwardhan, Ardan

    2005-10-01

    It has previously been shown that - in theory - magnification variations can occur in an imaging system as a function of defocus, depending on the field curvature of the illuminating system. We here present the results of practical experiments to verify this effect in the transmission electron microscope. We find that with illumination settings typically used in the electron microscopy of biological macromolecules, systematic variations in magnification of ~ 0.5% per μm defocus can easily occur. This work highlights the need for a magnification-invariant imaging mode to eliminate or to compensate for this effect.

  9. Development of a fast electromagnetic shutter for compressive sensing imaging in scanning transmission electron microscopy

    CERN Document Server

    Béché, Armand; Freitag, Bert; Verbeeck, Jo

    2015-01-01

    The concept of compressive sensing was recently proposed to significantly reduce the electron dose in scanning transmission electron microscopy (STEM) while still maintaining the main features in the image. Here, an experimental setup based on an electromagnetic shutter placed in the condenser plane of a STEM is proposed. The shutter blanks the beam following a random pattern while the scanning coils are moving the beam in the usual scan pattern. Experimental images at both medium scale and high resolution are acquired and then reconstructed based on a discrete cosine algorithm. The obtained results confirm the predicted usefulness of compressive sensing in experimental STEM even though some remaining artifacts need to be resolved.

  10. Reliable strain measurement in transistor arrays by robust scanning transmission electron microscopy

    Directory of Open Access Journals (Sweden)

    Suhyun Kim

    2013-09-01

    Full Text Available Accurate measurement of the strain field in the channels of transistor arrays is critical for strain engineering in modern electronic devices. We applied atomic-resolution high-angle annular dark-field scanning transmission electron microscopy to quantitative measurement of the strain field in transistor arrays. The quantitative strain profile over 20 transistors was obtained with high reliability and a precision of 0.1%. The strain field was found to form homogeneously in the channels of the transistor arrays. Furthermore, strain relaxation due to the thin foil effect was quantitatively investigated for thicknesses of 35 to 275 nm.

  11. Defects in paramagnetic Co-doped ZnO films studied by transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kovacs, Andras; Ney, A.; Duchamp, Martial; Ney, V.; Boothroyd, Chris; Galindo, Pedro L.; Kaspar, Tiffany C.; Chambers, Scott A.; Dunin-Borkowski, Rafal

    2013-12-23

    We have studied planar defects in epitaxial Co:ZnO dilute magnetic semiconductor thin films deposited on c-plane sapphire (Al2O3) and the Co:ZnO/Al2O3 interface structure at atomic resolution using aberration-corrected transmission electron microscopy (TEM) and electron energy-loss spectroscopy (EELS). Comparing Co:ZnO samples deposited by pulsed laser deposition and reactive magnetron sputtering, both exhibit extrinsic stacking faults, incoherent interface structures, and compositional variations within the first 3-4 Co:ZnO layers at the interface.. In addition, we have measured the local strain which reveals the lattice distortion around the stacking faults.

  12. Employing NMR Spectroscopy To Evaluate Transmission of Electronic Effects in 4-Substituted Chalcones

    Science.gov (United States)

    Wachter-Jurcsak, Nanette; Zamani, Hossein

    1999-05-01

    Described is an organic synthesis experiment that demonstrates the electronic transmission by substituents. The effect of substitution at the para-position of the styryl ring of 1,3-diphenyl-2-propenones (chalcones) by typical electron-donating or -accepting groups can be observed by proton and carbon-13 NMR spectroscopy. A linear correlation is observed when the differences in chemical shift measurements for H are plotted against the corresponding Hammett substituent constant values. Good correlation between carbon-13 chemical shifts of the alpha carbon are also observed. The syntheses of the 4-substituted chalcones is presented as well as a brief discussion of the theory.

  13. Transmission dosimetry with a liquid-filled electronic portal imaging device

    Energy Technology Data Exchange (ETDEWEB)

    Boellaard, R.; Van Herk, M.; Mijnheer, B.J. [Nederlands Kanker Inst. `Antoni van Leeuwenhoekhuis`, Amsterdam (Netherlands)

    1995-12-01

    The aim of transmission dosimetry is to correlate transmission dose values with patient dose values. A liquid-filled electronic portal imaging device (EPID) has been developed. After determination of the dose response relationship, i.e. the relation between pixel value and dose rate, for clinical situations it was found that the EPID is applicable for two-dimensional dosimetry with an accuracy of about 1%. The aim of this study was to investigate transmission dose distributions at different phantom-detector distances to predict exit dose distributions from transmission dose images. An extensive set of transmission dose measurements below homogeneous phantoms were performed with the EPID. The influence of several parameters such as field size, phantom thickness, phantom-detector distance and phantom-source distance on the transmission dose and its distribution were investigated. The two-dimensional transmission dose images were separated into two components: a primary dose and a scattered dose distribution. It was found that the scattered dose is maximal at a phantom thickness of about 10 cm. The scattered dose distribution below a homogeneous phantom has a Gaussian shape. The width of the Gaussian is small at small phantom-detector distances and increases for larger phantom-detector distances. The dependence of the scattered dose distribution on the field size at various phantom-detector distances has been used to estimate the dose distribution at the exit site of the phantom. More work is underway to determine the exit dose distributions for clinical situations, including the presence of inhomogeneities.

  14. Extension of Pierce model to multiple transmission lines interacting with an electron beam

    CERN Document Server

    Tamma, Venkata Ananth

    2013-01-01

    A possible route towards achieving high power microwave devices is through the use of novel slow-wave structures employing multiple coupled transmission lines (MTLs) whose behavior when coupled to electron beams have not been sufficiently explored. We present the extension of the one-dimensional linearized Pierce theory to MTLs coupled to a single electron beam. We develop multiple formalisms to calculate the k-{\\omega} dispersion relation of the system and find that the existence of a growing wave solution is always guaranteed if the electron propagation constant is larger than or equal to the largest propagation constant of the MTL system. We verify our findings with illustrative examples which bring to light unique properties of the system in which growing waves were found to exist within finite bands of the electron propagation constant and discuss possible approach to improve the gain. By treating the beam-MTL interaction as distributed dependent current generators in the MTL, we derive relations charact...

  15. Fine structure of the endolymphatic duct in the rat. A scanning and transmission electron microscopy study

    DEFF Research Database (Denmark)

    Qvortrup, K; Rostgaard, Jørgen; Bretlau, P

    1995-01-01

    To investigate the surface morphology of the endolymphatic duct epithelium, 8 rats were vascularly perfused with glutaraldehyde in a buffered and oxygenated blood substitute. Optimal preservation of the epithelium for scanning electron microscopy was attained by coating of the specimens with OsO4...... and thiocarbohydrazide followed by a continuous dehydration procedure. Three types of cells were identified with the scanning electron microscope: A polygonal and oblong epithelial cell was observed in the largest number throughout the duct, whereas in the juxta-saccular half of the duct two additional types...... of epithelial cells were observed. The scanning electron microscopical observations are compared and discussed with reference to transmission electron microscopical observations of the endolymphatic duct....

  16. Possibilities and limitations of advanced transmission electron microscopy for carbon-based nanomaterials

    Directory of Open Access Journals (Sweden)

    Xiaoxing Ke

    2015-07-01

    Full Text Available A major revolution for electron microscopy in the past decade is the introduction of aberration correction, which enables one to increase both the spatial resolution and the energy resolution to the optical limit. Aberration correction has contributed significantly to the imaging at low operating voltages. This is crucial for carbon-based nanomaterials which are sensitive to electron irradiation. The research of carbon nanomaterials and nanohybrids, in particular the fundamental understanding of defects and interfaces, can now be carried out in unprecedented detail by aberration-corrected transmission electron microscopy (AC-TEM. This review discusses new possibilities and limits of AC-TEM at low voltage, including the structural imaging at atomic resolution, in three dimensions and spectroscopic investigation of chemistry and bonding. In situ TEM of carbon-based nanomaterials is discussed and illustrated through recent reports with particular emphasis on the underlying physics of interactions between electrons and carbon atoms.

  17. Possibilities and limitations of advanced transmission electron microscopy for carbon-based nanomaterials.

    Science.gov (United States)

    Ke, Xiaoxing; Bittencourt, Carla; Van Tendeloo, Gustaaf

    2015-01-01

    A major revolution for electron microscopy in the past decade is the introduction of aberration correction, which enables one to increase both the spatial resolution and the energy resolution to the optical limit. Aberration correction has contributed significantly to the imaging at low operating voltages. This is crucial for carbon-based nanomaterials which are sensitive to electron irradiation. The research of carbon nanomaterials and nanohybrids, in particular the fundamental understanding of defects and interfaces, can now be carried out in unprecedented detail by aberration-corrected transmission electron microscopy (AC-TEM). This review discusses new possibilities and limits of AC-TEM at low voltage, including the structural imaging at atomic resolution, in three dimensions and spectroscopic investigation of chemistry and bonding. In situ TEM of carbon-based nanomaterials is discussed and illustrated through recent reports with particular emphasis on the underlying physics of interactions between electrons and carbon atoms.

  18. A correlative light microscopic, transmission and scanning electron microscopic study of the dorsum of human tongue.

    Science.gov (United States)

    Boshell, J L; Wilborn, W H; Singh, B B

    1980-01-01

    The dorsum of the human tongue has three types of papillae, filiform, fungiform and circumvallate. Some investigators have studied these by light and transmission electron microscopy. Since knowledge of the morphology through studies by scanning of the morphology through studies by scanning electron microscopy (SEM) is scant, this investigation was started with the purpose of studying human tongues at different ages. One fetal tongue and portions of three tongues from newborns were removed. Additional specimens were biopsied from the anterior region of three adult tongues. Samples were processed routinely for light microscopy, transmission electron microscoy (TEM) and scanning electron microscopy (SEM). Two distinct features were evident on the fetal tongue. The first was that the surface epithelial layer of the tongue appeared to be periderm. The second was that fungiform papillae began their development earlier than filiform. At birth, the putative periderm had disappeared and a few filiform papillae were observed. On the adult tongue, filiform papillae were numerous and were comprised of two cell populations. One cell population contained numerous keratohyalin granules (KHG). The KHG were two types, eosinophilic and basophilic. Ultrastructurally, the eosinophilic granules were less electron dense and larger in size than the basophilic KHG.

  19. Electron tomography based on a total variation minimization reconstruction technique

    Energy Technology Data Exchange (ETDEWEB)

    Goris, B., E-mail: bart.goris@ua.ac.be [EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium); Van den Broek, W. [EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium); Batenburg, K.J. [Centrum Wiskunde and Informatica, Science Park 123, NL-1098XG Amsterdam (Netherlands); Vision Lab, University of Antwerp, Universiteitsplein 1, B-2610 Wilrijk (Belgium); Heidari Mezerji, H.; Bals, S. [EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium)

    2012-02-15

    The 3D reconstruction of a tilt series for electron tomography is mostly carried out using the weighted backprojection (WBP) algorithm or using one of the iterative algorithms such as the simultaneous iterative reconstruction technique (SIRT). However, it is known that these reconstruction algorithms cannot compensate for the missing wedge. Here, we apply a new reconstruction algorithm for electron tomography, which is based on compressive sensing. This is a field in image processing specialized in finding a sparse solution or a solution with a sparse gradient to a set of ill-posed linear equations. Therefore, it can be applied to electron tomography where the reconstructed objects often have a sparse gradient at the nanoscale. Using a combination of different simulated and experimental datasets, it is shown that missing wedge artefacts are reduced in the final reconstruction. Moreover, it seems that the reconstructed datasets have a higher fidelity and are easier to segment in comparison to reconstructions obtained by more conventional iterative algorithms. -- Highlights: Black-Right-Pointing-Pointer A reconstruction algorithm for electron tomography is investigated based on total variation minimization. Black-Right-Pointing-Pointer Missing wedge artefacts are reduced by this algorithm. Black-Right-Pointing-Pointer The reconstruction is easier to segment. Black-Right-Pointing-Pointer More reliable quantitative information can be obtained.

  20. Development of electron optical system using annular pupils for scanning transmission electron microscope by focused ion beam

    Energy Technology Data Exchange (ETDEWEB)

    Matsutani, Takaomi, E-mail: matutani@ele.kindai.ac.jp [Kinki University, 3-4-1 Kowakae, Higashiosaka, Osaka 577-8502 (Japan); Yasumoto, Tsuchika; Tanaka, Takeo [Osaka Sangyo University, 3-1-1 Nakagaito, Daito, Osaka 574-8530 (Japan); Kawasaki, Tadahiro; Ichihashi, Mikio [Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan); Ikuta, Takashi [Osaka Electro-Communication University, 18-8 Hatsu-cho, Neyagawa, Osaka 572-8530 (Japan)

    2012-02-01

    Annular pupils for electron optics were produced using a focused ion beam (FIB), enabling an increase in the depth of focus and allowing for aberration-free imaging and separation of the amplitude and phase images in a scanning transmission electron microscope (STEM). Simulations demonstrate that an increased focal depth is advantageous for three-dimensional tomography in the STEM. For a 200 kV electron beam, the focal depth is increased to approximately 100 nm by using an annular pupil with inner and outer semi-angles of 29 and 30 mrad, respectively. Annular pupils were designed with various outer diameters of 40-120 {mu}m and the inner diameter was designed at 80% of the outer diameter. A taper angle varying from 1 Degree-Sign to 20 Degree-Sign was applied to the slits of the annular pupils to suppress the influence of high-energy electron scattering. The fabricated annular pupils were inspected by scanning ion beam microscopy and scanning electron microscopy. These annular pupils were loaded into a STEM and no charge-up effects were observed in the scintillator projection images recorded by a CCD camera.

  1. Kinetics of liquid-mediated crystallization of amorphous Ge from multi-frame dynamic transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Santala, M. K., E-mail: melissa.santala@oregonstate.edu; Campbell, G. H. [Materials Science Division, Lawrence Livermore National Laboratory, 7000 East Ave., Livermore, California 94551 (United States); Raoux, S. [Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Hahn-Meitner-Platz 1, D-14109 Berlin (Germany)

    2015-12-21

    The kinetics of laser-induced, liquid-mediated crystallization of amorphous Ge thin films were studied using multi-frame dynamic transmission electron microscopy (DTEM), a nanosecond-scale photo-emission transmission electron microscopy technique. In these experiments, high temperature gradients are established in thin amorphous Ge films with a 12-ns laser pulse with a Gaussian spatial profile. The hottest region at the center of the laser spot crystallizes in ∼100 ns and becomes nano-crystalline. Over the next several hundred nanoseconds crystallization continues radially outward from the nano-crystalline region forming elongated grains, some many microns long. The growth rate during the formation of these radial grains is measured with time-resolved imaging experiments. Crystal growth rates exceed 10 m/s, which are consistent with crystallization mediated by a very thin, undercooled transient liquid layer, rather than a purely solid-state transformation mechanism. The kinetics of this growth mode have been studied in detail under steady-state conditions, but here we provide a detailed study of liquid-mediated growth in high temperature gradients. Unexpectedly, the propagation rate of the crystallization front was observed to remain constant during this growth mode even when passing through large local temperature gradients, in stark contrast to other similar studies that suggested the growth rate changed dramatically. The high throughput of multi-frame DTEM provides gives a more complete picture of the role of temperature and temperature gradient on laser crystallization than previous DTEM experiments.

  2. Multiple double cross-section transmission electron microscope sample preparation of specific sub-10 nm diameter Si nanowire devices.

    Science.gov (United States)

    Gignac, Lynne M; Mittal, Surbhi; Bangsaruntip, Sarunya; Cohen, Guy M; Sleight, Jeffrey W

    2011-12-01

    The ability to prepare multiple cross-section transmission electron microscope (XTEM) samples from one XTEM sample of specific sub-10 nm features was demonstrated. Sub-10 nm diameter Si nanowire (NW) devices were initially cross-sectioned using a dual-beam focused ion beam system in a direction running parallel to the device channel. From this XTEM sample, both low- and high-resolution transmission electron microscope (TEM) images were obtained from six separate, specific site Si NW devices. The XTEM sample was then re-sectioned in four separate locations in a direction perpendicular to the device channel: 90° from the original XTEM sample direction. Three of the four XTEM samples were successfully sectioned in the gate region of the device. From these three samples, low- and high-resolution TEM images of the Si NW were taken and measurements of the NW diameters were obtained. This technique demonstrated the ability to obtain high-resolution TEM images in directions 90° from one another of multiple, specific sub-10 nm features that were spaced 1.1 μm apart.

  3. Magnetic-field-modulated written bits in TbFeCo thin films: Transmission electron microscopy Lorentz and scanning electron microscopy with polarization analysis studies

    Science.gov (United States)

    Aeschlimann, M.; Scheinfein, M.; Unguris, J.; Greidanus, F. J. A. M.; Klahn, S.

    1990-11-01

    Domains written thermomagnetically in TbFeCo thin films are studied with Lorentz transmission electron microscopy (TEM) and scanning electron microscopy with polarization analysis (SEMPA). Four different rare-earth/transition-metal compositions TbxFeyCo1-x-y are examined. The domain structures observed with both techniques are similar even though TEM Lorentz only detects the transverse component of the net magnetic field along the electron's trajectory through the sample, while SEMPA detects the surface electron-spin polarization (magnetization). We find that the magnetic contrast in the SEMPA measurements is proportional to the magnetization of the transition-metal (TM) subnetwork which is antiferromagnetically coupled to the rare-earth (RE) subnetwork. This allows high-contrast SEMPA images to be acquired even when the system is magnetically compensated (Ms=‖MRE-MTM‖=0). The surface magnetization can be explained by assuming that the surface of the TbFeCo alloy consists of an outermost thin oxide layer followed by an Fe-rich subsurface layer. The importance of the demagnetizing field on the switching and domain nucleation process for thermomagnetically written bits is examined.

  4. Magnetic-field-modulated written bits in TbFeCo thin films: Transmission electron microscopy Lorentz and scanning electron microscopy with polarization analysis studies

    Energy Technology Data Exchange (ETDEWEB)

    Aeschlimann, M.; Scheinfein, M.; Unguris, J. (National Institute of Standards and Technology, Gaithersburg, Maryland 20899 (USA) Greidanus, F.J.A.M. (Philips Research Laboratories, P.O. Box 80.000, 5600 JA, Eindhoven (The Netherlands)))

    1990-11-01

    Domains written thermomagnetically in TbFeCo thin films are studied with Lorentz transmission electron microscopy (TEM) and scanning electron microscopy with polarization analysis (SEMPA). Four different rare-earth/transition-metal compositions Tb{sub {ital x}}Fe{sub {ital y}}Co{sub 1{minus}{ital x}{minus}{ital y}} are examined. The domain structures observed with both techniques are similar even though TEM Lorentz only detects the transverse component of the net magnetic field along the electron's trajectory through the sample, while SEMPA detects the surface electron-spin polarization (magnetization). We find that the magnetic contrast in the SEMPA measurements is proportional to the magnetization of the transition-metal (TM) subnetwork which is antiferromagnetically coupled to the rare-earth (RE) subnetwork. This allows high-contrast SEMPA images to be acquired even when the system is magnetically compensated ({ital M}{sub {ital s}}={vert bar}{ital M}{sub RE}{minus}{ital M}{sub TM}{vert bar}=0). The surface magnetization can be explained by assuming that the surface of the TbFeCo alloy consists of an outermost thin oxide layer followed by an Fe-rich subsurface layer. The importance of the demagnetizing field on the switching and domain nucleation process for thermomagnetically written bits is examined.

  5. Data processing techniques for a wireless data transmission application via mud

    Directory of Open Access Journals (Sweden)

    Zhao Qingjie

    2011-01-01

    Full Text Available Abstract The data measured by well bottom sensors can be transmitted to the surface through the drilling mud during oil drilling operations. This article introduces a data processing scheme for a wireless data transmission application via mud. The detailed signal processing procedure is given, and several data processing techniques used are discussed, mainly including data encoding and signal integrating method, signal filtering, data storage and manage method, peak detection, signal recognition, and data decoding method. The article uses M pulses in N slots to encode the values of actual parameters. A two step filtering method and a dynamic data storing and managing method are proposed. A mix peak detection method is utilized to find the position of a pulse by combining threshold method and neighbor comparison method. These techniques have been successfully used in an oil well drilling operation.

  6. Data processing techniques for a wireless data transmission application via mud

    Science.gov (United States)

    Zhao, Qingjie; Zhang, Baojun; Wang, Wei

    2011-12-01

    The data measured by well bottom sensors can be transmitted to the surface through the drilling mud during oil drilling operations. This article introduces a data processing scheme for a wireless data transmission application via mud. The detailed signal processing procedure is given, and several data processing techniques used are discussed, mainly including data encoding and signal integrating method, signal filtering, data storage and manage method, peak detection, signal recognition, and data decoding method. The article uses M pulses in N slots to encode the values of actual parameters. A two step filtering method and a dynamic data storing and managing method are proposed. A mix peak detection method is utilized to find the position of a pulse by combining threshold method and neighbor comparison method. These techniques have been successfully used in an oil well drilling operation.

  7. a Reciprocity Technique for the Characterisation of Sound Transmission Into Aircraft Fuselages.

    Science.gov (United States)

    Mason, James Meredith

    1990-01-01

    Available from UMI in association with The British Library. Experimental determination of the sound insulation of propfan aircraft fuselage structures is problematic. The use of full-scale flight tests to investigate and optimise sidewall design is expensive, while the use of simplified excitation tests is questionable, due to the complicated nature of propeller sound fields and their interaction with the fuselage. This thesis describes the development and evaluation of a new experimental reciprocity technique for calibrating a fuselage as a transmitter of pressure acting on the external surface to the interior: it is based upon the use of a transducer which measures the volume velocity of the vibrating fuselage surface. The data generated may be combined with any impinging sound field to obtain a prediction of cabin sound pressure level. In the first instance, the technique is validated for sound transmission through flat panels into a rigid walled box and the results presented demonstrate the validity of the approach. Tests are then conducted on a set of four quarter-scale 'green' fuselage model configurations, constructed to investigate the influence of ring frame bending-stiffness, stringers and floor on airborne sound transmission. Interior noise predictions are obtained for plane wave excitation and a representation of propeller sound field excitation. The important features relating to correct representation of the excitation field and the fuselage structure are isolated, within the scope of the models evaluated. In addition, a statistical perturbation technique is described which demonstrates confidence in the predictions. The technique is recommended for evaluation on a full size airframe.

  8. Accurate Virus Quantitation Using a Scanning Transmission Electron Microscopy (STEM) Detector in a Scanning Electron Microscope

    Science.gov (United States)

    2017-06-29

    remove any viral aggregation. Nutrient rich media was required for virus growth, but this media resulted in crystallized salt and sugar deposits on the...1940s using a spray or centrifugation technique to deposit the sample on the supporting media , followed by negative staining with 2% Uranyl Acetate...being handled 2,3. Choosing a cell line, media , and other variables are essential to a successful plaque assay 3. Plaque assay has the lowest limit of

  9. CMOS pixel sensor response to low energy electrons in transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Battaglia, Marco [Department of Physics, University of California at Berkeley, CA 94720 (United States); Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States)], E-mail: MBattaglia@lbl.gov; Contarato, Devis; Denes, Peter; Doering, Dionisio; Radmilovic, Velimir [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States)

    2009-07-01

    This letter presents the results of a study of the response of a test CMOS sensor with a radiation tolerant pixel cell design to 80 and 100 keV electrons. The point spread function is measured to be (13.0{+-}1.7){mu}m at 100 keV and (12.1{+-}1.6){mu}m at 80 keV, for 20{mu}m pixels. Results agree well with values predicted by a Geant-4 and dedicated charge collection simulation.

  10. A technique for pediatric total skin electron irradiation

    Directory of Open Access Journals (Sweden)

    Bao Qinan

    2012-03-01

    Full Text Available Abstract Background Total skin electron irradiation (TSEI is a special radiotherapy technique which has generally been used for treating adult patients with mycosis fungoides. Recently, two infants presented with leukemia cutis isolated to the skin requiring TSEI. This work discusses the commissioning and quality assurance (QA methods for implementing a modified Stanford technique using a rotating harness system to position sedated pediatric patients treated with electrons to the total skin. Methods and Results Commissioning of pediatric TSEI consisted of absolute calibration, measurement of dosimetric parameters, and subsequent verification in a pediatric patient sized cylindrical phantom using radiographic film and optically stimulated luminance (OSL dosimeters. The depth of dose penetration under TSEI treatment condition was evaluated using radiographic film sandwiched in the phantom and demonstrated a 2 cm penetration depth with the maximum dose located at the phantom surface. Dosimetry measurements on the cylindrical phantom and in-vivo measurements from the patients suggested that, the factor relating the skin and calibration point doses (i.e., the B-factor was larger for the pediatric TSEI treatments as compared to adult TSEI treatments. Custom made equipment, including a rotating plate and harness, was fabricated and added to a standard total body irradiation stand and tested to facilitate patient setup under sedated condition. A pediatric TSEI QA program, consisting of daily output, energy, flatness, and symmetry measurements as well as in-vivo dosimetry verification for the first cycle was developed. With a long interval between pediatric TSEI cases, absolute dosimetry was also repeated as part of the QA program. In-vivo dosimetry for the first two infants showed that a dose of ± 10% of the prescription dose can be achieved over the entire patient body. Conclusion Though pediatric leukemia cutis and the subsequent need for TSEI are

  11. Tip alignment system in a sextupole-corrected scanning transmission electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Ruan, S. (The Enrico Fermi Institute, The University of Chicago, Chicago, Illinois 60637 (United States)); Kapp, O.H. (The Department of Radiology and The Enrico Fermi Institute, The University of Chicago, Chicago, Illinois 60637 (United States))

    1993-03-01

    Tip alignment and replacement in ultrahigh vacuum field-emission electron microscopes is traditionally a time-consuming endeavor. A convenient autodrive system for the 200 kV scanning transmission electron microscope was developed to facilitate the alignment of field-emission tips, thus saving a great deal of experimenter time. Under computer control, a series of automatic electrical and mechanical processes are initiated to systematically adjust various parameters to effect passage of the electron beam through the various apertures of the microscope column. The task of finding the beam'' is thus performed automatically. In this process the tip holder is moved in a raster parallel to the first anode. Feedback from various detectors placed throughout the column direct the positioning of the tip for optimal alignment. This process is routinely performed in about 45 min.

  12. Scanning and transmission electron microscopic study of equine infectious anemia virus.

    Science.gov (United States)

    Gonda, M A; Charman, H P; Walker, J L; Coggins, L

    1978-05-01

    Scanning and transmission electron microscopy were used to study in detail the morphogenesis and replication of equine infectious anemia virus (EIAV) in cultured, persistently infected equine fetal kidney fibroblasts. The EIAV was shown by thin-section electron microscopy to resemble morphologically more closely the members of the genus Lenti-virus in the family Retroviridae than other genera. Scanning electron microscopy demonstrated budding virus on only about 5% of the equine fetal kidney fibroblasts; however, the entire surface of these cells was involved in viral replication. Except where virus budding was observed, EIAV-infected cells were smooth and free of the topographic surface alterations characteristic of cells transformed by type C retroviruses. The morphologic relationship of EIAV and pathologic manifestations of EIAV infection to those of other Retroviridae are discussed.

  13. Atomistic observations and analyses of lattice defects in transmission electron microscopes

    CERN Document Server

    Abe, H

    2003-01-01

    The transmission electron microscope (TEM) -accelerators was developed. TEM-Accelerator made possible to observe in situ experiments of ion irradiation and implantation. The main results are the experimental proof of new lattice defects by irradiation, the formation process and synthesized conditions of carbon onion by ion implantation, the microstructure and phase transformation conditions of graphite by ion irradiated phase transformation, the irradiation damage formation process by simultaneous irradiation of electron and ion and behavior of fullerene whisker under irradiation. The microstructural evolution of defect clusters in copper irradiated with 240-keV Cu sup + ions and a high resolution electron micrograph of carbon onions synthesized by ion implantation are explained as the examples of recent researches. (S.Y.)

  14. Energy-filtered transmission electron microscopy of biological samples on highly transparent carbon nanomembranes

    CERN Document Server

    Rhinow, Daniel; Weber, Nils-Eike; Beyer, André; Gölzhäuser, Armin; Kühlbrandt, Werner; Hampp, Norbert; Turchanin, Andrey; 10.1016/j.ultramic.2011.01.028

    2011-01-01

    Ultrathin carbon nanomembranes (CNM) comprising crosslinked biphenyl precursors have been tested as support films for energy-filtered transmission electron microscopy (EFTEM) of biological specimens. Due to their high transparency CNM are ideal substrates for electron energy loss spectroscopy (EELS) and electron spectroscopic imaging (ESI) of stained and unstained biological samples. Virtually background-free elemental maps of tobacco mosaic virus (TMV) and ferritin have been obtained from samples supported by ~ 1 nm thin CNM. Furthermore, we have tested conductive carbon nanomembranes (cCNM) comprising nanocrystalline graphene, obtained by thermal treatment of CNM, as supports for cryoEM of ice-embedded biological samples. We imaged ice-embedded TMV on cCNM and compared the results with images of ice-embedded TMV on conventional carbon film (CC), thus analyzing the gain in contrast for TMV on cCNM in a quantitative manner. In addition we have developed a method for the preparation of vitrified specimens, sus...

  15. Investigating the use of in situ liquid cell scanning transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Nguy, Amanda [Iowa State Univ., Ames, IA (United States)

    2016-02-19

    Engineering nanoparticles with desired shape-dependent properties is the key to many applications in nanotechnology. Although many synthetic procedures exist to produce anisotropic gold nanoparticles, the dynamics of growth are typically unknown or hypothetical. In the case of seed-mediated growth in the presence of DNA into anisotropic nanoparticles, it is not known exactly how DNA directs growth into specific morphologies. A series of preliminary experiments were carried out to contribute to the investigation of the possible mechanism of DNA-mediated growth of gold nanoprisms into gold nanostars using liquid cell scanning transmission electron microscopy (STEM). Imaging in the liquid phase was achieved through the use of a liquid cell platform and liquid cell holder that allow the sample to be contained within a “chip sandwich” between two electron transparent windows. Ex situ growth experiments were performed using Au-T30 NPrisms (30-base thymine oligonucleotide-coated gold nanoprisms) that are expected to grow into gold nanostars. Growth to form these nanostars were imaged using TEM (transmission electron microscopy) and liquid cell STEM (scanning transmission electron microscopy). An attempt to perform in situ growth experiments with the same Au-T30 nanoprisms revealed challenges in obtaining desired morphology results due to the environmental differences within the liquid cell compared to the ex situ environment. Different parameters in the experimental method were explored including fluid line set up, simultaneous and alternating reagent addition, and the effect of different liquid cell volumes to ensure adequate flow of reagents into the liquid cell. Lastly, the binding affinities were compared for T30 and A30 DNA incubated with gold nanoparticles using zeta potential measurements, absorption spectroscopy, and isothermal titration calorimetry (ITC). It was previously reported thymine bases have a lower binding affinity to gold surfaces than adenine

  16. Investigation on experimental techniques to detect, locate and quantify gear noise in helicopter transmissions

    Science.gov (United States)

    Flanagan, P. M.; Atherton, W. J.

    1985-01-01

    A robotic system to automate the detection, location, and quantification of gear noise using acoustic intensity measurement techniques has been successfully developed. Major system components fabricated under this grant include an instrumentation robot arm, a robot digital control unit and system software. A commercial, desktop computer, spectrum analyzer and two microphone probe complete the equipment required for the Robotic Acoustic Intensity Measurement System (RAIMS). Large-scale acoustic studies of gear noise in helicopter transmissions cannot be performed accurately and reliably using presently available instrumentation and techniques. Operator safety is a major concern in certain gear noise studies due to the operating environment. The man-hours needed to document a noise field in situ is another shortcoming of present techniques. RAIMS was designed to reduce the labor and hazard in collecting data and to improve the accuracy and repeatability of characterizing the acoustic field by automating the measurement process. Using RAIMS a system operator can remotely control the instrumentation robot to scan surface areas and volumes generating acoustic intensity information using the two microphone technique. Acoustic intensity studies requiring hours of scan time can be performed automatically without operator assistance. During a scan sequence, the acoustic intensity probe is positioned by the robot and acoustic intensity data is collected, processed, and stored.

  17. Practical Considerations for High Spatial and Temporal Resolution Dynamic Transmission Electron Microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Armstrong, M; Boyden, K; Browning, N D; Campbell, G H; Colvin, J D; DeHope, B; Frank, A M; Gibson, D J; Hartemann, F; Kim, J S; King, W E; LaGrange, T B; Pyke, B J; Reed, B W; Shuttlesworth, R M; Stuart, B C; Torralva, B R

    2006-05-01

    Although recent years have seen significant advances in the spatial resolution possible in the transmission electron microscope (TEM), the temporal resolution of most microscopes is limited to video rate at best. This lack of temporal resolution means that our understanding of dynamic processes in materials is extremely limited. High temporal resolution in the TEM can be achieved, however, by replacing the normal thermionic or field emission source with a photoemission source. In this case the temporal resolution is limited only by the ability to create a short pulse of photoexcited electrons in the source, and this can be as short as a few femtoseconds. The operation of the photo-emission source and the control of the subsequent pulse of electrons (containing as many as 5 x 10{sup 7} electrons) create significant challenges for a standard microscope column that is designed to operate with a single electron in the column at any one time. In this paper, the generation and control of electron pulses in the TEM to obtain a temporal resolution <10{sup -6} s will be described and the effect of the pulse duration and current density on the spatial resolution of the instrument will be examined. The potential of these levels of temporal and spatial resolution for the study of dynamic materials processes will also be discussed.

  18. High Dynamic Range Pixel Array Detector for Scanning Transmission Electron Microscopy.

    Science.gov (United States)

    Tate, Mark W; Purohit, Prafull; Chamberlain, Darol; Nguyen, Kayla X; Hovden, Robert; Chang, Celesta S; Deb, Pratiti; Turgut, Emrah; Heron, John T; Schlom, Darrell G; Ralph, Daniel C; Fuchs, Gregory D; Shanks, Katherine S; Philipp, Hugh T; Muller, David A; Gruner, Sol M

    2016-02-01

    We describe a hybrid pixel array detector (electron microscope pixel array detector, or EMPAD) adapted for use in electron microscope applications, especially as a universal detector for scanning transmission electron microscopy. The 128×128 pixel detector consists of a 500 µm thick silicon diode array bump-bonded pixel-by-pixel to an application-specific integrated circuit. The in-pixel circuitry provides a 1,000,000:1 dynamic range within a single frame, allowing the direct electron beam to be imaged while still maintaining single electron sensitivity. A 1.1 kHz framing rate enables rapid data collection and minimizes sample drift distortions while scanning. By capturing the entire unsaturated diffraction pattern in scanning mode, one can simultaneously capture bright field, dark field, and phase contrast information, as well as being able to analyze the full scattering distribution, allowing true center of mass imaging. The scattering is recorded on an absolute scale, so that information such as local sample thickness can be directly determined. This paper describes the detector architecture, data acquisition system, and preliminary results from experiments with 80-200 keV electron beams.

  19. A menu of electron probes for optimising information from scanning transmission electron microscopy.

    Science.gov (United States)

    Nguyen, D T; Findlay, S D; Etheridge, J

    2017-09-07

    We assess a selection of electron probes in terms of the spatial resolution with which information can be derived about the structure of a specimen, as opposed to the nominal image resolution. Using Ge [001] as a study case, we investigate the scattering dynamics of these probes and determine their relative merits in terms of two qualitative criteria: interaction volume and interpretability. This analysis provides a 'menu of probes' from which an optimum probe for tackling a given materials science question can be selected. Hollow cone, vortex and spherical wave fronts are considered, from unit cell to Ångstrom size, and for different defocus and specimen orientations. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Toward Ending the Guessing Game: Study of the Formation of Nanostructures Using In Situ Liquid Transmission Electron Microscopy.

    Science.gov (United States)

    Ngo, Thao; Yang, Hong

    2015-12-17

    The field of synthetic nanochemistry has grown tremendously in the past three decades since the discovery of nonaqueous synthesis of monodispersed particles. Almost all classes of materials, from II-VI semiconductor to metal, alloy, and metal oxide can now be prepared in various sizes and shapes. One major challenge has been the development of a technique for direct real-time recording of data during the formation of nanostructures in liquid reaction media where nucleation and growth occur. A viable solution finally arrived with the recent development of static and flow liquid cells for transmission electron microscopy (TEM). This Perspective will showcase a few selected examples in this rapidly growing area, with a focus on using the new capabilities of liquid TEM (LTEM) for quantitative study of nucleation and growth, as well as shape formation of nanocrystals in solution. A discussion on future direction is also presented.

  1. Diaminobenzidine photoconversion is a suitable tool for tracking the intracellular location of fluorescently labelled nanoparticles at transmission electron microscopy

    Directory of Open Access Journals (Sweden)

    M. Malatesta

    2012-04-01

    Full Text Available Chitosan-based nanoparticles (NPs deserve particular attention as suitable drug carriers in the field of pharmaceutics, since they are able to protect the encapsulated drugs and/or improve their efficacy by making them able to cross biological barriers (such as the blood-brain barrier and reach their intracellular target sites. Understanding the intracellular location of NPs is crucial for designing drug delivery strategies. In this study, fluorescently-labelled chitosan NPs were administered in vitro to a neuronal cell line, and diaminobenzidine (DAB photoconversion was applied to correlate fluorescence and transmission electron microscopy to precisely describe the NPs intracellular fate. This technique allowed to demonstrate that chitosan NPs easily enter neuronal cells, predominantly by endocytosis; they were found both inside membrane-bounded vesicles and free in the cytosol, and were observed to accumulate around the cell nucleus.

  2. Measurement of the penetration depth and coherence length of MgB2 in all directions using transmission electron microscopy

    DEFF Research Database (Denmark)

    Loudon, J. C.; Yazdi, Sadegh; Kasama, Takeshi

    2015-01-01

    the crystallographic a axis. A new method was developed to simulate these images that accounted for vortices with a nonzero core in a thin, anisotropic superconductor and a simplex algorithm was used to make a quantitative comparison between the images and simulations to measure the penetration depths and coherence...... gives Lambda(ab) = 107 +/- 8 nm, Lambda(c) = 120 +/- 15 nm, xi(ab) = 39 +/- 11 nm, and xi(c) = 35 +/- 10 nm, which agree well with measurements made using other techniques. The experiment required two days to conduct and does not require large-scale facilities. It was performed on a very small sample......We demonstrate that images of flux vortices in a superconductor taken with a transmission electron microscope can be used to measure the penetration depth and coherence length in all directions at the same temperature and magnetic field. This is particularly useful for MgB2, where these quantities...

  3. Determination of the volume-specific surface area by using transmission electron tomography for characterization and definition of nanomaterials

    Directory of Open Access Journals (Sweden)

    Francisco Michel

    2011-05-01

    Full Text Available Abstract Background Transmission electron microscopy (TEM remains an important technique to investigate the size, shape and surface characteristics of particles at the nanometer scale. Resulting micrographs are two dimensional projections of objects and their interpretation can be difficult. Recently, electron tomography (ET is increasingly used to reveal the morphology of nanomaterials (NM in 3D. In this study, we examined the feasibility to visualize and measure silica and gold NM in suspension using conventional bright field electron tomography. Results The general morphology of gold and silica NM was visualized in 3D by conventional TEM in bright field mode. In orthoslices of the examined NM the surface features of a NM could be seen and measured without interference of higher or lower lying structures inherent to conventional TEM. Segmentation by isosurface rendering allowed visualizing the 3D information of an electron tomographic reconstruction in greater detail than digital slicing. From the 3D reconstructions, the surface area and the volume of the examined NM could be estimated directly and the volume-specific surface area (VSSA was calculated. The mean VSSA of all examined NM was significantly larger than the threshold of 60 m2/cm3. The high correlation between the measured values of area and volume gold nanoparticles with a known spherical morphology and the areas and volumes calculated from the equivalent circle diameter (ECD of projected nanoparticles (NP indicates that the values measured from electron tomographic reconstructions are valid for these gold particles. Conclusion The characterization and definition of the examined gold and silica NM can benefit from application of conventional bright field electron tomography: the NM can be visualized in 3D, while surface features and the VSSA can be measured.

  4. Measurement of the transmission phase of an electron in a quantum two-path interferometer

    Energy Technology Data Exchange (ETDEWEB)

    Takada, S., E-mail: shintaro.takada@neel.cnrs.fr; Watanabe, K. [Department of Applied Physics, University of Tokyo, Bunkyo-ku, Tokyo 113-8656 (Japan); Yamamoto, M. [Department of Applied Physics, University of Tokyo, Bunkyo-ku, Tokyo 113-8656 (Japan); PRESTO, JST, Kawaguchi-shi, Saitama 331-0012 (Japan); Bäuerle, C. [Université Grenoble Alpes, Institut NEEL, F-38042 Grenoble (France); CNRS, Institut NEEL, F-38042 Grenoble (France); Ludwig, A.; Wieck, A. D. [Lehrstuhl für Angewandte Festkörperphysik, Ruhr-Universität Bochum, Universitätsstraße 150, 44780 Bochum (Germany); Tarucha, S. [Department of Applied Physics, University of Tokyo, Bunkyo-ku, Tokyo 113-8656 (Japan); Center for Emergent Matter Science (CEMS), RIKEN, Wako, Saitama 351-0198 (Japan)

    2015-08-10

    A quantum two-path interferometer allows for direct measurement of the transmission phase shift of an electron, providing useful information on coherent scattering problems. In mesoscopic systems, however, the two-path interference is easily smeared by contributions from other paths, and this makes it difficult to observe the true transmission phase shift. To eliminate this problem, multi-terminal Aharonov-Bohm (AB) interferometers have been used to derive the phase shift by assuming that the relative phase shift of the electrons between the two paths is simply obtained when a smooth shift of the AB oscillations is observed. Nevertheless, the phase shifts using such a criterion have sometimes been inconsistent with theory. On the other hand, we have used an AB ring contacted to tunnel-coupled wires and acquired the phase shift consistent with theory when the two output currents through the coupled wires oscillate with well-defined anti-phase. Here, we investigate thoroughly these two criteria used to ensure a reliable phase measurement, the anti-phase relation of the two output currents, and the smooth phase shift in the AB oscillation. We confirm that the well-defined anti-phase relation ensures a correct phase measurement with a quantum two-path interference. In contrast, we find that even in a situation where the anti-phase relation is less well-defined, the smooth phase shift in the AB oscillation can still occur but does not give the correct transmission phase due to contributions from multiple paths. This indicates that the phase relation of the two output currents in our interferometer gives a good criterion for the measurement of the true transmission phase, while the smooth phase shift in the AB oscillation itself does not.

  5. Studying Dynamic Processes of Nano-sized Objects in Liquid using Scanning Transmission Electron Microscopy.

    Science.gov (United States)

    Hermannsdörfer, Justus; de Jonge, Niels

    2017-02-05

    Samples fully embedded in liquid can be studied at a nanoscale spatial resolution with Scanning Transmission Electron Microscopy (STEM) using a microfluidic chamber assembled in the specimen holder for Transmission Electron Microscopy (TEM) and STEM. The microfluidic system consists of two silicon microchips supporting thin Silicon Nitride (SiN) membrane windows. This article describes the basic steps of sample loading and data acquisition. Most important of all is to ensure that the liquid compartment is correctly assembled, thus providing a thin liquid layer and a vacuum seal. This protocol also includes a number of tests necessary to perform during sample loading in order to ensure correct assembly. Once the sample is loaded in the electron microscope, the liquid thickness needs to be measured. Incorrect assembly may result in a too-thick liquid, while a too-thin liquid may indicate the absence of liquid, such as when a bubble is formed. Finally, the protocol explains how images are taken and how dynamic processes can be studied. A sample containing AuNPs is imaged both in pure water and in saline.

  6. Structural deteriorations of the human peritoneum during laparoscopic cholecystectomy. A transmission electron microscopic study.

    Science.gov (United States)

    Tarhan, Omer Ridvan; Barut, Ibrahim; Ozogul, Candan; Bozkurt, Serkan; Baykara, Basak; Bulbul, Mahmut

    2013-08-01

    In previous studies, changes in the surface of the peritoneum during laparoscopic surgery are well defined. Nevertheless, almost all of these studies were performed on rodents via scanning electron microscopy. In the present study, structural alterations of the mesothelial cells of peritoneum were examined during laparoscopic cholecystectomy using transmission electron microscopy. Twenty patients with symptomatic cholelithiasis were included in the study. Peritoneal biopsy was performed immediately after CO2 pneumoperitoneum creation and at the end of surgery just before gallbladder removal. Biopsies were taken from the right upper quadrant, i.e., apart from operative manipulation. Peritoneal sample cross-sections were compared using transmission electron microscopy. The carbon dioxide pneumoperitoneum during laparoscopic cholecystectomy caused deteriorations of the peritoneal mesothelium. Apoptosis were developed in mesothelial cells. Bulging of mesothelial cells, irregular cell junctions, focal intercellular clefts, apical cell membrane degeneration, deep nuclear invaginations, and lipid droplets in the cytoplasm of the mesothelial cells were other remarkable findings. Mesothelial edema also was determined. As seen in previous studies, basement membrane nudity appeared after carbon dioxide pneumoperitoneum could be attributable to mesothelial cell apoptosis, deterioration of the cell structure, and cell organelles.

  7. 3D simulation of electron and ion transmission of GEM-based detectors

    Science.gov (United States)

    Bhattacharya, Purba; Mohanty, Bedangadas; Mukhopadhyay, Supratik; Majumdar, Nayana; da Luz, Hugo Natal

    2017-10-01

    Time Projection Chamber (TPC) has been chosen as the main tracking system in several high-flux and high repetition rate experiments. These include on-going experiments such as ALICE and future experiments such as PANDA at FAIR and ILC. Different R&D activities were carried out on the adoption of Gas Electron Multiplier (GEM) as the gas amplification stage of the ALICE-TPC upgrade version. The requirement of low ion feedback has been established through these activities. Low ion feedback minimizes distortions due to space charge and maintains the necessary values of detector gain and energy resolution. In the present work, Garfield simulation framework has been used to study the related physical processes occurring within single, triple and quadruple GEM detectors. Ion backflow and electron transmission of quadruple GEMs, made up of foils with different hole pitch under different electromagnetic field configurations (the projected solutions for the ALICE TPC) have been studied. Finally a new triple GEM detector configuration with low ion backflow fraction and good electron transmission properties has been proposed as a simpler GEM-based alternative suitable for TPCs for future collider experiments.

  8. On the role of inelastic scattering in phase-plate transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Hettler, Simon, E-mail: simon.hettler@kit.edu [Laboratorium für Elektronenmikroskopie, Karlsruher Institut für Technologie (KIT), Engesserstr. 7, 76131 Karlsruhe (Germany); Wagner, Jochen; Dries, Manuel [Laboratorium für Elektronenmikroskopie, Karlsruher Institut für Technologie (KIT), Engesserstr. 7, 76131 Karlsruhe (Germany); Oster, Marco; Wacker, Christian; Schröder, Rasmus R. [CellNetworks, BioQuant, Universität Heidelberg, Im Neuenheimer Feld 267, 69120 Heidelberg (Germany); Gerthsen, Dagmar [Laboratorium für Elektronenmikroskopie, Karlsruher Institut für Technologie (KIT), Engesserstr. 7, 76131 Karlsruhe (Germany)

    2015-08-15

    The phase contrast of Au nanoparticles on amorphous-carbon films with different thicknesses is analyzed using an electrostatic Zach phase plate in a Zeiss 912 Ω transmission electron microscope with in-column energy filter. Specifically, unfiltered and plasmon-filtered phase-plate transmission electron microscopy (PP TEM) images are compared to gain insight in the role of coherence after inelastic scattering processes. A considerable phase-contrast contribution resulting from a combined elastic–inelastic scattering process is found in plasmon-filtered PP TEM images. The contrast reduction compared to unfiltered images mainly originates from zero-order beam broadening caused by the inelastic scattering process. The effect of the sequence of the elastic and inelastic scattering processes is studied by varying the position of the nanoparticles, which can be either located on top or at the bottom of the amorphous-carbon film with respect to the incident electron beam direction. - Highlights: • Combined application of electrostatic Zach phase plate and energy filter in a TEM. • Contrast analysis of Au nanoparticles on amorphous carbon films. • Phase contrast inversion in unfiltered images by Zach phase plate. • Phase contrast in plasmon-filtered images by inelastic–elastic scattering process. • Analysis of different effects on nanoparticle contrast.

  9. Interaction of Metals with Suspended Graphene Observed by Transmission Electron Microscopy.

    Science.gov (United States)

    Zan, Recep; Bangert, Ursel; Ramasse, Quentin; Novoselov, Konstantin S

    2012-04-05

    In this Perspective, we present an overview of how different metals interface with suspended graphene, providing a closer look into the metal-graphene interaction by employing high-resolution transmission electron microscopy, especially using high-angle dark field imaging. All studied metals favor sites on the omnipresent hydrocarbon surface contamination rather than on the clean graphene surface and present nonuniform distributions, which never result in continuous films but instead in clusters or nanocrystals, indicating a weak interaction between the metal and graphene. This behavior can be altered to some degree by surface pretreatment (hydrogenation) and high-temperature vacuum annealing. Graphene etching is observed in a scanning transmission electron microscope (STEM) under high vacuum and 60 kV electron beam acceleration voltage conditions for all metals, except for Au. This unusual metal-mediated etching sheds new light on the metal-graphene interaction; it might explain the observed higher frequency of cluster nucleation for certain transition metals and might have implications regarding controlled nanomanipulation, that is, for self-assembly and sculpturing of future graphene-based devices.

  10. In situ environmental transmission electron microscope investigation of NiGa nanoparticle synthesis

    DEFF Research Database (Denmark)

    Damsgaard, Christian Danvad; Duchstein, Linus Daniel Leonhard; Elkjær, Christian Fink

    2011-01-01

    detailed Environmental Transmission Electron Microscope (ETEM) investigations of synthesis of NiGa nanoparticles on a thin film support. Samples were prepared by dissolving Ni(NO3)2 and Ga(NO3)3 in a Ni:Ga ratio of 5:3 in millipore water. The solution was subsequently dispersed on transmission electron...... microscope (TEM) sample grids. The sample grid was then mounted in a TEM heating holder and inserted in a FEI Titan ETEM with imaging Cs corrector as well as facilities for in situ gas reactions [3]. The ETEM was operated at 300 kV. The synthesis was performed in situ in a H2 flow of 2 Nml/min at a pressure...... of 130 Pa. The reaction was investigated from room temperature (RT) to 660°C by subsequently obtaining bright field TEM images, diffraction patterns (DP), High Resolution TEM (HRTEM) images, and Electron Energy Loss Spectroscopy (EELS) data. Figure 1 shows bright field images of the sample during...

  11. The High Resolution Transmission Electron Microscopy: A Powerful Tool for Studying the Organization of Terrestrial and Extra-Terrestrial Carbons

    Science.gov (United States)

    Rouzaud, J.-N.; Skrzypczak, A.; Bonal, L.; Derenne, S.; Quirico, E.; Robert, F.

    2005-03-01

    High Resolution Transmission Electron Microscopy (HRTEM) makes possible the imaging of the profile of the polyaromatic layers, allowing a knowledge of carbons, such as disordered natural carbons from meteorites and from Precambrian metasediments

  12. Three-dimensional imaging of individual point defects using selective detection angles in annular dark field scanning transmission electron microscopy.

    Science.gov (United States)

    Johnson, Jared M; Im, Soohyun; Windl, Wolfgang; Hwang, Jinwoo

    2017-01-01

    We propose a new scanning transmission electron microscopy (STEM) technique that can realize the three-dimensional (3D) characterization of vacancies, lighter and heavier dopants with high precision. Using multislice STEM imaging and diffraction simulations of β-Ga2O3 and SrTiO3, we show that selecting a small range of low scattering angles can make the contrast of the defect-containing atomic columns substantially more depth-dependent. The origin of the depth-dependence is the de-channeling of electrons due to the existence of a point defect in the atomic column, which creates extra "ripples" at low scattering angles. The highest contrast of the point defect can be achieved when the de-channeling signal is captured using the 20-40mrad detection angle range. The effect of sample thickness, crystal orientation, local strain, probe convergence angle, and experimental uncertainty to the depth-dependent contrast of the point defect will also be discussed. The proposed technique therefore opens new possibilities for highly precise 3D structural characterization of individual point defects in functional materials.

  13. Three-dimensional shapes and distribution of FePd nanoparticles observed by electron tomography using high-angle annular dark-field scanning transmission electron microscopy

    Science.gov (United States)

    Sato, Kazuhisa; Aoyagi, Kenta; Konno, Toyohiko J.

    2010-01-01

    We have studied three-dimensional shapes and distribution of FePd nanoparticles, prepared by electron beam deposition and postdeposition annealing, by means of single-axis tilt tomography using atomic number contrasts obtained by high-angle annular dark-field scanning transmission electron microscopy. Particle size, shape, and locations were reconstructed by weighted backprojection (WBP), as well as by simultaneous iterative reconstruction technique (SIRT). We have also estimated the particle size by simple extrapolation of tilt-series original data sets, which proved to be quite powerful. The results of the two algorithms for reconstruction have been compared quantitatively with those obtained by the extrapolation method and those independently reported by electron holography. It was found that the reconstructed intensity map by WBP contains a small amount of dotlike artifacts, which do not exist in the results by SIRT, and that the particle surface obtained by WBP is rougher than that by SIRT. We demonstrate, on the other hand, that WBP yields a better estimation of the particle size in the z direction than SIRT does, most likely due to the presence of a "missing wedge" in the original data set.

  14. Simulation calculation for the energy deposition profile and the transmission fraction of intense pulsed electron beam at various incident angles

    CERN Document Server

    Yang Hai Liang; Zhang Jia Sheng; Huang Jian Jun; Sun Jian Feng

    2002-01-01

    The incident angles have a heavy effect on the intense pulsed electron beam energy deposition profile, energy deposition fraction and beam current transmission fraction in material. The author presents electron beam energy deposition profile and energy deposition fraction versus electron energy (0.5-2.0 MeV), at various incident angles for three aluminum targets of various thickness via theoretical calculation. The intense pulsed electron beam current transmission fractions versus electron energy (0.4-1.4 MeV) at various incident angles for three thickness of carbon targets were also theoretically calculated. The calculation results indicate that the deposition energy in unit mass of material surface layer increase with the rise of electron beam incident angle, and electron beam with low incident angle (closer to normal incident angle) penetrates deeper into the target material. The electron beams deposit more energy in unit mass of material surface layer at 60 degree-70 degree incident angle

  15. Carbon Nanostructure Examined by Lattice Fringe Analysis of High Resolution Transmission Electron Microscopy Images

    Science.gov (United States)

    VanderWal, Randy L.; Tomasek, Aaron J.; Street, Kenneth; Thompson, William K.; Hull, David R.

    2003-01-01

    The dimensions of graphitic layer planes directly affect the reactivity of soot towards oxidation and growth. Quantification of graphitic structure could be used to develop and test correlations between the soot nanostructure and its reactivity. Based upon transmission electron microscopy images, this paper provides a demonstration of the robustness of a fringe image analysis code for determining the level of graphitic structure within nanoscale carbon, i.e., soot. Results, in the form of histograms of graphitic layer plane lengths, are compared to their determination through Raman analysis.

  16. In situ investigation of the mechanical properties of nanomaterials by transmission electron microscopy

    Institute of Scientific and Technical Information of China (English)

    Jun Sun; Feng Xu; Li-Tao Sun

    2012-01-01

    With the progress of modern transmission electron microscopy (TEM) and development of dedicated functional TEM specimen holders,people can now manipulate a nano-object with nanometer-range precision and simultaneously acquire mechanical data together with atomic-scale structural information.This advanced methodology is playing an increasingly important role in nanomechanics.The present review summarizes relevant studies on the in situ investigation of mechanical properties of various nanomaterials over the past decades.These works enrich our knowledge not only on nanomaterials (such as carbon nanotubes,carbon onions,boron nitride nanotubes,silicon nanowires and graphene,etc.) but also on mechanics at the nanoscale.

  17. High-resolution transmission electron microscopy and energetics of flattened carbon nonoshells

    Energy Technology Data Exchange (ETDEWEB)

    Bourgeois, L.N.; Bursill, L.A

    1998-09-01

    When examined under a high-resolution transmission electron microscope, carbon soot produced alongside buckytubes in an arc-discharge is found to contain a small percentage of flattened carbon shells. These objects are shown to be small graphite flakes which eliminated their dangling bonds by terminating their edges with highly curved junctions. Ideal models for these structures are presented, and their energy estimated. The calculations show that the establishment of highly curved junctions is energetically favourable for a graphite flake in an inert atmosphere. Flattened shells also appear more stable than their `inflated` counterparts (fullerene `onions` and buckytubes) when the shell dimensions obey specific criteria.(authors) 29 refs., 4 figs.

  18. Nanocrystal Diffusion in a Liquid Thin Film Observed by in situ Transmission Electron Microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Haimei; Claridge, Shelley A.; Minor, Andrew M.; Alivisatos, A. Paul; Dahmen, Ulrich

    2009-04-17

    We have directly observed motion of inorganic nanoparticles during fluid evaporation using a Transmission Electron Microscope. Tracking real-time diffusion of both spherical (5-15 nm) and rod-shaped (5x10 nm) gold nanocrystals in a thin-film of water-15percentglycerol reveals complex movements, such as rolling motions coupled to large-step movements and macroscopic violations of the Stokes-Einstein relation for diffusion. As drying patches form during the final stages of evaporation, particle motion is dominated by the nearby retracting liquid front.

  19. Nanoscale experimental study of the morphology of a microcrack in silicon by transmission electron microscopy

    Indian Academy of Sciences (India)

    D S Liu; C W Zhao; X H Hou

    2013-05-01

    A microcrack in a silicon single crystal was experimentally investigated using highresolution transmission electron microscopy (HRTEM). In particular, the numerical Moiré (NM) method was used to visualize the deformations and defects. The lattice structure of the microcrack was carefully observed at the nanoscale. HRTEM images of the microcrack demonstrated that the lattice structure of most of the microcrack regions is regular with good periodicity. In addition, the microcrack cleavage expands alternately along different crystal planes, where the principal cleavage plane is the (1 1 1) crystal plane. The NM maps showed no sharp plastic deformation around the microcrack, but discrete edge dislocations can be found only near the crack tip.

  20. Soot Nanostructure: Using Fringe Analysis Software on High Resolution Transmission Electron Microscopy of Carbon Soot

    Science.gov (United States)

    King, James D.

    2004-01-01

    Using high resolution transmission electron images of carbon nanotubes and carbon particles, we are able to use image analysis program to determine several carbon fringe properties, including length, separation, curvature and orientation. Results are shown in the form of histograms for each of those quantities. The combination of those measurements can give a better indication of the graphic structure within nanotubes and particles of carbon and can distinguish carbons based upon fringe properties. Carbon with longer, straighter and closer spaced fringes are considered graphite, while amorphous carbon contain shorter, less structured fringes.

  1. Long distance electron transmission couples sulphur, iron, calcium and oxygen cycling in marine sediment

    DEFF Research Database (Denmark)

    Risgaard-Petersen, Nils; Nielsen, Lars Peter

    sulfide oxidation leads to electric field formation, sulfide depletion and acidification of the upper centimeters of the sediment. This promoted ion migration and dissolution of carbonates and iron sulfides. Sulfide released from iron sulfides was the major e-donor in the system. Ferrous iron released...... from iron sulfides was to a large extend deposited in the oxic zone as iron oxides and Ca2+ eventually precipitates at the surface as due to high pH caused by cathodic oxygen reduction. The result show how long distance electron transmission allows oxygen to drive the allocation of important minerals...

  2. Scanning transmission electron microscopy analysis of grain structure in perpendicular magnetic recording media.

    Science.gov (United States)

    Hossein-Babaei, Faraz; Sinclair, Robert; Sinclair, Robert A; Srinivasan, Kumar; Bertero, Gerardo A

    2011-09-14

    The key component of a hard disk medium is a Co-based magnetic layer (ML) grown on a Ru seed layer. The ML nanostructure, composed of less than 10 nm grains, is believed to be controlled by this seed layer. We successfully used scanning transmission electron microscopy energy dispersive spectrometry simultaneous composition-based imaging and Moiré pattern analysis for determining the mutual structural and orientation relationship between the two layers revealing a grain-to-grain agreement. The method presented here can be utilized for observing structural correlations between consecutive polycrystalline thin film layers in general.

  3. Transmission electron microscopy study of vertical quantum dots molecules grown by droplet epitaxy

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez-Maldonado, D., E-mail: david.hernandez@uca.es [Departamento de Ciencia de los Materiales e I.M. y Q.I., Facultad de Ciencias, Universidad de Cadiz, Campus Rio San Pedro, s/n, 11510 Puerto Real, Cadiz (Spain); Herrera, M.; Sales, D.L. [Departamento de Ciencia de los Materiales e I.M. y Q.I., Facultad de Ciencias, Universidad de Cadiz, Campus Rio San Pedro, s/n, 11510 Puerto Real, Cadiz (Spain); Alonso-Gonzalez, P.; Gonzalez, Y.; Gonzalez, L. [Instituto de Microelectronica de Madrid (CNM-CSIC), Isaac Newton 8 (PTM), 28760 Tres Cantos, Madrid (Spain); Pizarro, J.; Galindo, P.L. [Departamento de Lenguajes y Sistemas Informaticos, CASEM, Universidad de Cadiz, Campus Rio San Pedro, s/n, 11510 Puerto Real, Cadiz (Spain); Molina, S.I. [Departamento de Ciencia de los Materiales e I.M. y Q.I., Facultad de Ciencias, Universidad de Cadiz, Campus Rio San Pedro, s/n, 11510 Puerto Real, Cadiz (Spain)

    2010-07-01

    The compositional distribution of InAs quantum dots grown by molecular beam epitaxy on GaAs capped InAs quantum dots has been studied in this work. Upper quantum dots are nucleated preferentially on top of the quantum dots underneath, which have been nucleated by droplet epitaxy. The growth process of these nanostructures, which are usually called as quantum dots molecules, has been explained. In order to understand this growth process, the analysis of the strain has been carried out from a 3D model of the nanostructure built from transmission electron microscopy images sensitive to the composition.

  4. Dynamics of annular bright field imaging in scanning transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Findlay, S.D., E-mail: scott@sigma.t.u-tokyo.ac.jp [Institute of Engineering Innovation, The University of Tokyo, Tokyo 116-0013 (Japan); Shibata, N. [Institute of Engineering Innovation, The University of Tokyo, Tokyo 116-0013 (Japan); PRESTO, Japan Science and Technology Agency, Saitama 332-0012 (Japan); Sawada, H.; Okunishi, E.; Kondo, Y. [JEOL Ltd., Tokyo 196-8558 (Japan); Ikuhara, Y. [Institute of Engineering Innovation, The University of Tokyo, Tokyo 116-0013 (Japan); Nanostructures Research Laboratory, Japan Fine Ceramics Center, Nagoya 456-8587 (Japan); WPI Advanced Institute for Materials Research, Tohoku University, Sendai 980-8577 (Japan)

    2010-06-15

    We explore the dynamics of image formation in the so-called annular bright field mode in scanning transmission electron microscopy, whereby an annular detector is used with detector collection range lying within the cone of illumination, i.e. the bright field region. We show that this imaging mode allows us to reliably image both light and heavy columns over a range of thickness and defocus values, and we explain the contrast mechanisms involved. The role of probe and detector aperture sizes is considered, as is the sensitivity of the method to intercolumn spacing and local disorder.

  5. Transmission electron microscopy characterization of microstructural features of Al-Li-Cu alloys

    Science.gov (United States)

    Avalos-Borja, M.; Pizzo, P. P.; Larson, L. A.

    1983-01-01

    A transmission electron microscopy (TEM) examination of aluminum-lithium-copper alloys was conducted. The principal purpose is to characterize the nature, size, and distribution of stringer particles which result from the powder metallurgy (P/M) processing of these alloys. Microstructural features associated with the stringer particles are reported that help explain the stress corrosion susceptibility of the powder metallurgy-processed Al-Li-Cu alloys. In addition, matrix precipitation events are documented for a variety of heat treatments and process variations. Hot rolling is observed to significant alter the nature of matrix precipitation, and the observations are correlated with concomitant mechanical property variations.

  6. Compositional analysis of GaAs/AlGaAs heterostructures using quantitative scanning transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kauko, H.; Helvoort, A. T. J. van [Department of Physics, Norwegian University of Science and Technology (NTNU), Trondheim (Norway); Zheng, C. L.; Glanvill, S. [Monash Centre for Electron Microscopy, Monash University, VIC 3800 (Australia); Zhu, Y.; Etheridge, J., E-mail: joanne.etheridge@monash.edu [Monash Centre for Electron Microscopy, Monash University, VIC 3800 (Australia); Department of Materials Engineering, Monash University, VIC 3800 (Australia); Dwyer, C. [Monash Centre for Electron Microscopy, Monash University, VIC 3800 (Australia); Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons, and Peter Grünberg Institute, Forschungszentrum Jülich, D-52425 Jülich (Germany); Munshi, A. M.; Fimland, B. O. [Department of Electronics and Telecommunications, Norwegian University of Science and Technology (NTNU), Trondheim (Norway)

    2013-12-02

    We demonstrate a method for compositional mapping of Al{sub x}Ga{sub 1–x}As heterostructures with high accuracy and unit cell spatial resolution using quantitative high angle annular dark field scanning transmission electron microscopy. The method is low dose relative to spectroscopic methods and insensitive to the effective source size and higher order lens aberrations. We apply the method to study the spatial variation in Al concentration in cross-sectioned GaAs/AlGaAs core-shell nanowires and quantify the concentration in the Al-rich radial band and the AlGaAs shell segments.

  7. Tunable photon transmission through a waveguide cavity coupled to an electron spin ensemble

    Science.gov (United States)

    Feng, Zhi-Bo; Yan, Run-Ying; Yan, Lei-Lei; Zhou, Yun-Qing

    2017-02-01

    We propose an effective scheme for implementing tunable photon transmission through a coplanar waveguide cavity. An electron spin ensemble of nitrogen-vacancy centers, behaving as a spin-boson mode, is coupled to the cavity mode. It is found that the transmittance of an incident photon depends on the coupling strength between the two modes, both with dissipative effects. In particular, the photon transmittance can be controlled at will by adjusting the external driving-induced detunings. This proposal could offer a promising avenue to coherently control photon propagation and is highly preferable for the experimental manipulations.

  8. Crack tip shielding observed with high-resolution transmission electron microscopy.

    Science.gov (United States)

    Adhika, Damar Rastri; Tanaka, Masaki; Daio, Takeshi; Higashida, Kenji

    2015-10-01

    The dislocation shielding field at a crack tip was experimentally proven at the atomic scale by measuring the local strain in front of the crack tip using high-resolution transmission electron microscopy (HRTEM) and geometric phase analysis (GPA). Single crystalline (110) silicon wafers were employed. Cracks were introduced using a Vickers indenter at room temperature. The crack tip region was observed using HRTEM followed by strain measurements using GPA. The measured strain field at the crack tip was compressive owing to dislocation shielding, which is in good agreement with the strain field calculated from elastic theory.

  9. In situ transmission electron microscopy of individual carbon nanotetrahedron/ribbon structures in bending

    Energy Technology Data Exchange (ETDEWEB)

    Kohno, Hideo, E-mail: kohno.hideo@kochi-tech.ac.jp [School of Environmental Science and Engineering, Kochi University of Technology, Kami, Kochi 782-8502 (Japan); Masuda, Yusuke [Graduate School of Science, Osaka University, Toyonaka, Osaka 560-0043 (Japan)

    2015-05-11

    When the direction of flattening of a carbon nanotube changes during growth mediated by a metal nanoparticle, a carbon nanotetrahedron is formed in the middle of the carbon nanoribbon. We report the bending properties of the carbon nanotetrahedron/nanoribbon structure using a micro-manipulator system in a transmission electron microscope. In many cases, bending occurs at an edge of the carbon nanotetrahedron. No significant change is observed in the tetrahedron's shape during bending, and the bending is reversible and repeatable. Our results show that the carbon nanotetrahedron/nanoribbon structure has good durability against mechanical bending.

  10. A platform for in-situ multi-probe electronic measurements and modification of nanodevices inside a transmission electron microscope

    Science.gov (United States)

    Xu, T. T.; Ning, Z. Y.; Shi, T. W.; Fu, M. Q.; Wang, J. Y.; Chen, Q.

    2014-06-01

    We developed a new platform that enables in-situ four-probe electronic measurements, in-situ three-probe field-effect measurements, nanomanipulation, and in-situ modification of nanodevices inside a transmission electron microscope (TEM). The platform includes a specially designed chip-holder and a silicon (Si) chip with suspended metal electrodes. The chip-holder can hold one Si chip with a size up to 3 mm × 3 mm and provides four electrical connections that can be connected to the micrometer-sized electrodes on the Si chip by wire-bonding. The other side of the electrical connections on the chip-holder is connected to the electronic instruments outside the TEM through a commercial Nanofactory SPM-TEM holder. The Si chip with suspended metal electrodes on one of its edges was fabricated by lithography and wet etching. Carbon nanotubes (CNTs), InAs nanowires, and tungsten disulfide nanowires were placed to stride over and connect to the suspended electrodes on the Si chip by nanomanipulations inside a scanning electron microscope (SEM). By using the platform, I-V curves of an individual single-walled CNT connecting to four electrodes were in-situ measured between any two of the four suspended electrodes, and a high-resolution TEM image of the same CNT was obtained. Furthermore, four-terminal I-V measurement on an InAs nanowire was achieved on this platform, and with a movable probe used as a gate electrode, field-effect measurement on the same InAs nanowire device was accomplished in SEM. In addition, by using the movable probe on the SPM-TEM holder, we could further in-situ modify nanomaterial and nanodevices. The present work demonstrates a method that allows a direct correlation between the atomic-level structure and the electronic property of nanomaterials or nanodevices whose structure can be further modified in-situ.

  11. In Situ Transmission Electron Microscopy Study of Electron Beam-Induced Transformations in Colloidal Cesium Lead Halide Perovskite Nanocrystals

    Science.gov (United States)

    2017-01-01

    An increasing number of studies have recently reported the rapid degradation of hybrid and all-inorganic lead halide perovskite nanocrystals under electron beam irradiation in the transmission electron microscope, with the formation of nanometer size, high contrast particles. The nature of these nanoparticles and the involved transformations in the perovskite nanocrystals are still a matter of debate. Herein, we have studied the effects of high energy (80/200 keV) electron irradiation on colloidal cesium lead bromide (CsPbBr3) nanocrystals with different shapes and sizes, especially 3 nm thick nanosheets, a morphology that facilitated the analysis of the various ongoing processes. Our results show that the CsPbBr3 nanocrystals undergo a radiolysis process, with electron stimulated desorption of a fraction of bromine atoms and the reduction of a fraction of Pb2+ ions to Pb0. Subsequently Pb0 atoms diffuse and aggregate, giving rise to the high contrast particles, as previously reported by various groups. The diffusion is facilitated by both high temperature and electron beam irradiation. The early stage Pb nanoparticles are epitaxially bound to the parent CsPbBr3 lattice, and evolve into nonepitaxially bound Pb crystals upon further irradiation, leading to local amorphization and consequent dismantling of the CsPbBr3 lattice. The comparison among CsPbBr3 nanocrystals with various shapes and sizes evidences that the damage is particularly pronounced at the corners and edges of the surface, due to a lower diffusion barrier for Pb0 on the surface than inside the crystal and the presence of a larger fraction of under-coordinated atoms. PMID:28122188

  12. Novel method for measurement of transistor gate length using energy-filtered transmission electron microscopy

    Science.gov (United States)

    Lee, Sungho; Kim, Tae-Hoon; Kang, Jonghyuk; Yang, Cheol-Woong

    2016-12-01

    As the feature size of devices continues to decrease, transmission electron microscopy (TEM) is becoming indispensable for measuring the critical dimension (CD) of structures. Semiconductors consist primarily of silicon-based materials such as silicon, silicon dioxide, and silicon nitride, and the electrons transmitted through a plan-view TEM sample provide diverse information about various overlapped silicon-based materials. This information is exceedingly complex, which makes it difficult to clarify the boundary to be measured. Therefore, we propose a simple measurement method using energy-filtered TEM (EF-TEM). A precise and effective measurement condition was obtained by determining the maximum value of the integrated area ratio of the electron energy loss spectrum at the boundary to be measured. This method employs an adjustable slit allowing only electrons with a certain energy range to pass. EF-TEM imaging showed a sharp transition at the boundary when the energy-filter’s passband centre was set at 90 eV, with a slit width of 40 eV. This was the optimum condition for the CD measurement of silicon-based materials involving silicon nitride. Electron energy loss spectroscopy (EELS) and EF-TEM images were used to verify this method, which makes it possible to measure the transistor gate length in a dynamic random access memory manufactured using 35 nm process technology. This method can be adapted to measure the CD of other non-silicon-based materials using the EELS area ratio of the boundary materials.

  13. High Dynamic Range Pixel Array Detector for Scanning Transmission Electron Microscopy

    CERN Document Server

    Tate, Mark W; Chamberlain, Darol; Nguyen, Kayla X; Hovden, Robert M; Chang, Celesta S; Deb, Pratiti; Turgut, Emrah; Heron, John T; Schlom, Darrell G; Ralph, Daniel C; Fuchs, Gregory D; Shanks, Katherine S; Philipp, Hugh T; Muller, David A; Gruner, Sol M

    2015-01-01

    We describe a hybrid pixel array detector (EMPAD - electron microscope pixel array detector) adapted for use in electron microscope applications, especially as a universal detector for scanning transmission electron microscopy. The 128 x 128 pixel detector consists of a 500 um thick silicon diode array bump-bonded pixel-by-pixel to an application-specific integrated circuit (ASIC). The in-pixel circuitry provides a 1,000,000:1 dynamic range within a single frame, allowing the direct electron beam to be imaged while still maintaining single electron sensitivity. A 1.1 kHz framing rate enables rapid data collection and minimizes sample drift distortions while scanning. By capturing the entire unsaturated diffraction pattern in scanning mode, one can simultaneously capture bright field, dark field, and phase contrast information, as well as being able to analyze the full scattering distribution, allowing true center of mass imaging. The scattering is recorded on an absolute scale, so that information such as loc...

  14. Energy-Efficient Network Transmission between Satellite Swarms and Earth Stations Based on Lyapunov Optimization Techniques

    Directory of Open Access Journals (Sweden)

    Weiwei Fang

    2014-01-01

    Full Text Available The recent advent of satellite swarm technologies has enabled space exploration with a massive number of picoclass, low-power, and low-weight spacecraft. However, developing swarm-based satellite systems, from conceptualization to validation, is a complex multidisciplinary activity. One of the primary challenges is how to achieve energy-efficient data transmission between the satellite swarm and terrestrial terminal stations. Employing Lyapunov optimization techniques, we present an online control algorithm to optimally dispatch traffic load among different satellite-ground links for minimizing overall energy consumption over time. Our algorithm is able to independently and simultaneously make control decisions on traffic dispatching over intersatellite-links and up-down-links so as to offer provable energy and delay guarantees, without requiring any statistical information of traffic arrivals and link condition. Rigorous analysis and extensive simulations have demonstrated the performance and robustness of the proposed new algorithm.

  15. Observing the Growth of Metal-Organic Frameworks by In-Situ Liquid Cell Transmission Electron Microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Patterson, Joseph P.; Abellan Baeza, Patricia; Denny, Michael S.; Park, Chiwoo; Browning, Nigel D.; Cohen, Seth M.; Evans, James E.; Gianneschi, Nathan C.

    2015-06-17

    Liquid Cell Transmission Electron Microscopy (LCTEM) can provide direct observations of solution phase nanoscale materials, and holds great promise as a tool for monitoring dynamic self assembly processes. Control over particle behavior within the liquid cell, and under electron beam irradiation, is of paramount importance for this technique to contribute to our understanding of chemistry and materials science at the nanoscale. However, this type of control has not been demonstrated for complex, organic macromolecular materials, which form the basis for all biological systems, all of polymer science, and encompass important classes of advanced porous materials. Here we show that by controlling the liquid cell surface chemistry and electron beam effects, the dynamics and self-assembly of metal-organic frameworks (MOFs) can be observed. Our results demonstrate that hybrid organic/inorganic beam sensitive materials can be analyzed with LCTEM and at least in the case of Zif-8 dynamics, the results correlate with observations from bulk growth or other standard synthetic conditions. We anticipate that direct, nanoscale imaging by LCTEM of MOF nucleation and growth mechanisms, may provide insight into controlled MOF crystal morphology, domain composition, and processes influencing defect formation.

  16. Dose limited reliability of quantitative annular dark field scanning transmission electron microscopy for nano-particle atom-counting

    Energy Technology Data Exchange (ETDEWEB)

    De Backer, A.; Martinez, G.T. [Electron Microscopy for Materials Science (EMAT), University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium); MacArthur, K.E.; Jones, L. [Department of Materials, University of Oxford, 16 Parks Road, Oxford OX1 3PH (United Kingdom); Béché, A. [Electron Microscopy for Materials Science (EMAT), University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium); Nellist, P.D. [Department of Materials, University of Oxford, 16 Parks Road, Oxford OX1 3PH (United Kingdom); Van Aert, S., E-mail: sandra.vanaert@uantwerpen.be [Electron Microscopy for Materials Science (EMAT), University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium)

    2015-04-15

    Quantitative annular dark field scanning transmission electron microscopy (ADF STEM) has become a powerful technique to characterise nano-particles on an atomic scale. Because of their limited size and beam sensitivity, the atomic structure of such particles may become extremely challenging to determine. Therefore keeping the incoming electron dose to a minimum is important. However, this may reduce the reliability of quantitative ADF STEM which will here be demonstrated for nano-particle atom-counting. Based on experimental ADF STEM images of a real industrial catalyst, we discuss the limits for counting the number of atoms in a projected atomic column with single atom sensitivity. We diagnose these limits by combining a thorough statistical method and detailed image simulations. - Highlights: • Limited size and beam sensitivity of nano-particles challenge their quantification. • Keeping the electron dose to a minimum is therefore important. • Reliability of quantitative ADF STEM for atom-counting is demonstrated. • Limits for single atom sensitivity are discussed. • Limits are diagnosed by combining simulations and a statistical method.

  17. A Document Imaging Technique for Implementing Electronic Loan Approval Process

    Directory of Open Access Journals (Sweden)

    J. Manikandan

    2015-04-01

    Full Text Available The image processing is one of the leading technologies of computer applications. Image processing is a type of signal processing, the input for image processor is an image or video frame and the output will be an image or subset of image [1]. Computer graphics and computer vision process uses an image processing techniques. Image processing systems are used in various environments like medical fields, computer-aided design (CAD, research fields, crime investigation fields and military fields. In this paper, we proposed a document image processing technique, for establishing electronic loan approval process (E-LAP [2]. Loan approval process has been tedious process, the E-LAP system attempts to reduce the complexity of loan approval process. Customers have to login to fill the loan application form online with all details and submit the form. The loan department then processes the submitted form and then sends an acknowledgement mail via the E-LAP to the requested customer with the details about list of documents required for the loan approval process [3]. The approaching customer can upload the scanned copies of all required documents. All this interaction between customer and bank take place using an E-LAP system.

  18. A Novel Noise Free Transmission Technique for Designing 100Gb/s Future Generation Optical Communication System

    DEFF Research Database (Denmark)

    Das, Bhagwan; Abdullah, M.F.L.; Pandey, Bishwajeet

    2017-01-01

    Differential Phase Shift Keying (DPSK) techniques are widely used in designing the high-speed communication systems. However, these techniques still need improvement for long haul communication system design. In this paper, high-speed optical signal transmission and reception system is achieved f...

  19. In situ analysis of gas composition by electron energy-loss spectroscopy for environmental transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Crozier, Peter A., E-mail: crozier@asu.edu [School for Engineering of Matter, Transport and Energy, Arizona State University Tempe, AZ 85287-6106 (United States); Chenna, Santhosh [School for Engineering of Matter, Transport and Energy, Arizona State University Tempe, AZ 85287-6106 (United States)

    2011-02-15

    We have developed methods for using in situ electron energy-loss spectroscopy (EELS) to perform quantitative analysis of gas in an environmental transmission electron microscope. Inner-shell EELS was able to successfully determine the composition of gas mixtures with an accuracy of about 15% or better provided that some precautions are taken during the acquisition to account for the extended gas path lengths associated with the reaction cell. The unique valence-loss spectrum associated with many gases allowed simple methodologies to be developed to determine gas composition from the low-loss region of the spectrum from a gas mixture. The advantage of the valence loss approach is that it allows hydrogen to be detected and quantified. EELS allows real-time analysis of the volume of gas inside the reaction cell and can be performed rapidly with typical acquisition times of a few seconds or less. This in situ gas analysis can also be useful for revealing mass transport issues associated with the differential gas diffusion through the system. -- Research Highlights: {yields} In situ electron energy-loss spectroscopy for gas analysis in ETEM. {yields} Compositional accuracy of about 15% or better. {yields} Can use core-loss or valence loss spectroscopy. {yields} Can detect mass transport property of gas handling system.

  20. Scanning transmission electron microscopic tomography of cortical bone using Z-contrast imaging.

    Science.gov (United States)

    McNally, Elizabeth; Nan, Feihong; Botton, Gianluigi A; Schwarcz, Henry P

    2013-06-01

    Previously we presented (McNally et al., 2012) a model for the ultrastructure of bone showing that the mineral resides principally outside collagen fibrils in the form of 5 nm thick mineral structures hundreds of nanometers long oriented parallel to the fibrils. Here we use high-angle annular dark-field electron tomography in the scanning transmission electron microscope to confirm this model and further elucidate the composite structure. Views of a section cut parallel to the fibril axes show bundles of mineral structures extending parallel to the fibrils and encircling them. The mineral density inside the fibrils is too low to be visualized in these tomographic images. A section cut perpendicular to the fibril axes, shows quasi-circular walls composed of mineral structures, wrapping around apparently empty holes marking the sites of fibrils. These images confirm our original model that the majority of mineral in bone resides outside the collagen fibrils.

  1. Switching behaviour of individual Ag-TCNQ nanowires: an in situ transmission electron microscopy study

    Science.gov (United States)

    Ran, Ke; Rösner, Benedikt; Butz, Benjamin; Fink, Rainer H.; Spiecker, Erdmann

    2016-10-01

    The organic semiconductor silver-tetracyanoquinodimethane (Ag-TCNQ) exhibits electrical switching and memory characteristics. Employing a scanning tunnelling microscopy setup inside a transmission electron microscope, the switching behaviour of individual Ag-TCNQ nanowires (NWs) is investigated in detail. For a large number of NWs, the switching between a high (OFF) and a low (ON) resistance state was successfully stimulated by negative bias sweeps. Fitting the experimental I-V curves with a Schottky emission function makes the switching features prominent and thus enables a direct evaluation of the switching process. A memory cycle including writing, reading and erasing features is demonstrated at an individual NW. Moreover, electronic failure mechanisms due to Joule heating are discussed. These findings have a significant impact on our understanding of the switching behaviour of Ag-TCNQ.

  2. In situ transmission electron microscopy of solid-liquid phase transition of silica encapsulated bismuth nanoparticles

    Science.gov (United States)

    Hu, Jianjun; Hong, Yan; Muratore, Chris; Su, Ming; Voevodin, Andrey A.

    2011-09-01

    The solid-liquid phase transition of silica encapsulated bismuth nanoparticles was studied by in situ transmission electron microscopy (TEM). The nanoparticles were prepared by a two-step chemical synthesis process involving thermal decomposition of organometallic precursors for nucleating bismuth and a sol-gel process for growing silica. The microstructural and chemical analyses of the nanoparticles were performed using high-resolution TEM, Z-contrast imaging, focused ion beam milling, and X-ray energy dispersive spectroscopy. Solid-liquid-solid phase transitions of the nanoparticles were directly recorded by electron diffractions and TEM images. The silica encapsulation of the nanoparticles prevented agglomeration and allowed particles to preserve their original volume upon melting, which is desirable for applications of phase change nanoparticles with consistently repeatable thermal properties.

  3. Atomic Resolution Imaging at an Ultralow Accelerating Voltage by a Monochromatic Transmission Electron Microscope

    Science.gov (United States)

    Morishita, Shigeyuki; Mukai, Masaki; Suenaga, Kazu; Sawada, Hidetaka

    2016-10-01

    Transmission electron microscopy using low-energy electrons would be very useful for atomic resolution imaging of specimens that would be damaged at higher energies. However, the resolution at low voltages is degraded because of geometrical and chromatic aberrations. In the present study, we diminish the effect of these aberrations by using a delta-type corrector and a monochromator. The dominant residual aberration in a delta-type corrector, which is the sixth-order three-lobe aberration, is counterbalanced by other threefold aberrations. Defocus spread caused by chromatic aberration is reduced by using a monochromated beam with an energy spread of 0.05 eV. We obtain images of graphene and demonstrate atomic resolution at an ultralow accelerating voltage of 15 kV.

  4. Cellulose Nanocrystals as Chiral Inducers: Enantioselective Catalysis and Transmission Electron Microscopy 3D Characterization.

    Science.gov (United States)

    Kaushik, Madhu; Basu, Kaustuv; Benoit, Charles; Cirtiu, Ciprian M; Vali, Hojatollah; Moores, Audrey

    2015-05-20

    Cellulose nanocrystals (CNCs), derived from cellulose, provide us with an opportunity to devise more sustainable solutions to current technological challenges. Enantioselective catalysis, especially heterogeneous, is the preferred method for the synthesis of pure chiral molecules in the fine chemical industries. Cellulose has been long sought as a chiral inducer in enantioselective catalysis. We report herein an unprecedentedly high enantiomeric excess (ee) for Pd patches deposited onto CNCs used as catalysts for the hydrogenation of prochiral ketones in water at room temperature and 4 bar H2. Our system, where CNCs acted as support and sole chiral source, achieved an ee of 65% with 100% conversions. Cryo-electron microscopy, high-resolution transmission electron microscopy, and tomography were used for the first time to study the 3D structure of a metal functionalized CNC hybrid. It established the presence of sub-nanometer-thick Pd patches at the surface of CNCs and provided insight into the chiral induction mechanism.

  5. Characterization of ionic permeability and water vapor transmission rate of polymers used for implantable electronics.

    Science.gov (United States)

    Kirsten, Sabine; Schubert, Martin; Uhlemann, Jürgen; Wolter, Klaus-Jurgen

    2014-01-01

    Biocompatible polymers used as encapsulation and packaging materials for implantable electronic devices have to comply with numerous requirements. Especially their barrier properties against water molecules and ions are of particular interest regarding the reliability of the encapsulation as well as functional integrity of the electronic components since water and ions on the circuit board may evoke corrosion, leakage current and finally the failure of the device. This paper describes a measurement setup to investigate the ionic permeability under in vitro conditions of polymeric membranes manufactured from various biocompatible polymers. Ionic permeability and water vapor transmission rate representing the barrier properties of these membranes were investigated. First results were obtained for polyimide, silicone, polyether ether ketone and polyamide, whereas polyimide evinced the best properties.

  6. Dendritic gold nanowire growth observed in liquid with transmission electron microscopy.

    Science.gov (United States)

    Kraus, Tobias; de Jonge, Niels

    2013-07-02

    The growth of nanoscale gold dendrites was studied in situ in a thin liquid film with transmission electron microscopy (TEM) using a liquid cell with silicon nitride (SiN) windows. Gold nanoparticle seeds were covered by a thin liquid layer containing precursor solution. Dendrite nucleation was induced by the electron beam leading to an initial burst of growth. The growth then settled at tip velocities between 0.1 and 2.0 nm/s for different dendrites. Tip velocities fluctuated as different dendrite geometries grew from the tips. Those dendrites showing granularities in their structure experienced the largest growth speed. Comparison of the observed velocities with diffusion-limited growth rates suggests that dendrite growth in thin films at this scale is limited by diffusion. The described method may find application in research on the mechanisms behind dendrite growth and also to study other types of anisotropic growth of nanomaterials driven by crystal and twin geometries.

  7. Balamuthia mandrillaris: Further morphological observations of trophozoites by light, scanning and transmission electron microscopy.

    Science.gov (United States)

    González-Robles, Arturo; Lares-Villa, Fernando; Lares-Jiménez, Luis Fernando; Omaña-Molina, Maritza; Salazar-Villatoro, Lizbeth; Martínez-Palomo, Adolfo

    2015-10-01

    Additional morphological features of Balamuthia mandrillaris observed by light and electron microscopy are reported. Trophozoites were extremely pleomorphic: their cell shapes ranged from rounded to elongated and sometimes they appeared exceptionally stretched out and branched. By transmission electron microscopy it was possible to observe two different cytoplasmic areas, the ectoplasm and the endoplasm and often sections of rough endoplasmic reticulum were found in the transition zone. The cytoplasm was very fibrogranular and most of the organelles typically found in eukaryotic cells were observed. A particular finding was the presence of numerous mitochondria with a different structure from those of other free-living amoebae. The observations reported here may reinforce the morphological knowledge of this amoeba and provide a background for further analyses.

  8. Prospects for lithium imaging using annular bright field scanning transmission electron microscopy: A theoretical study

    Energy Technology Data Exchange (ETDEWEB)

    Findlay, S.D., E-mail: scott@sigma.t.u-tokyo.ac.jp [Institute of Engineering Innovation, The University of Tokyo, Tokyo 116-0013 (Japan); Lugg, N.R. [School of Physics, University of Melbourne, Parkville, Victoria 3010 (Australia); Shibata, N. [Institute of Engineering Innovation, The University of Tokyo, Tokyo 116-0013 (Japan); PRESTO, Japan Science and Technology Agency, Saitama 332-0012 (Japan); Allen, L.J. [School of Physics, University of Melbourne, Parkville, Victoria 3010 (Australia); Ikuhara, Y. [Institute of Engineering Innovation, The University of Tokyo, Tokyo 116-0013 (Japan); Nanostructures Research Laboratory, Japan Fine Ceramic Center, Nagoya 456-8587 (Japan); WPI Advanced Institute for Materials Research, Tohoku University, Sendai 980-8577 (Japan)

    2011-07-15

    There is strong interest in lithium imaging, particularly because of its significance in battery materials. However, light atoms only scatter electrons weakly and atomic resolution direct imaging of lithium has proven difficult. This paper explores theoretically the conditions under which lithium columns can be expected to be directly visible using annular bright field scanning transmission electron microscopy. A detailed discussion is given of the controllable parameters and the conditions most favourable for lithium imaging. -- Highlights: {yields} Optimum conditions to image Li columns in Li-bearing materials with ABF are explored. {yields} Higher accelerating voltages give better contrast at a given resolution. {yields} Aperture size must compromise between resolution and good coupling to the column. {yields} Samples with small along-column interatomic spacing between Li atoms are best. {yields} The trends observed are consistent with prediction based on the s-state model.

  9. In situ transmission electron microscopy observations of sublimation in silver nanoparticles.

    Science.gov (United States)

    Asoro, Michael A; Kovar, Desiderio; Ferreira, Paulo J

    2013-09-24

    In situ heating experiments were performed in a transmission electron microscope (TEM) to monitor the thermal stability of silver nanoparticles. The sublimation kinetics from isothermal experiments on individual nanoparticles was used to assess the actual temperatures of the nanoparticles by considering the localized heating from the electron beam. For isolated nanoparticles, beam heating under normal TEM operating conditions was found to increase the temperature by tens of degrees. For nominally isothermal experiments, the observed sublimation temperatures generally decreased with decreasing particle size, in agreement with the predictions from the Kelvin equation. However, sublimation of smaller nanoparticles was often observed to occur in discrete steps, which led to faceting of the nanoparticles. This discrete behavior differs from that predicted by conventional theory as well as from experimental observations in larger nanoparticles where sublimation was continuous. A hypothesis that explains the mechanism for this size-dependent behavior is proposed.

  10. Direct observation of defect structure in protein crystals by atomic force and transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Devaud, G. (Department of Physics, University of Colorado, Boulder, Colorado 80309 (United States)); Furcinitti, P.S. (Department of Molecular, Cellular and Developmental Biology, University of Colorado, Boulder, Colorado 80309 (United States)); Fleming, J.C.; Lyon, M.K.; Douglas, K. (Department of Physics, University of Colorado, Boulder, Colorado 80309 (United States))

    1992-09-01

    We have examined the structure of S-layers isolated from {ital Sulfolobus} {ital acidocaldarius} using atomic force microscopy (AFM) and transmission electron microscopy (TEM). From the AFM images, we were able to directly observe individual dimers of the crystal, defects in the crystal structure, and twin boundaries. We have identified two types of boundaries, one defined by a mirror plane and the other by a glide plane. This work shows that twin boundaries are highly structured regions that are directly related to the organization of units within each crystal domain. Projection maps from TEM images have shown that there are significant differences in the final average maps, depending on which side of the sample is adsorbed to the carbon support film. Comparison of AFM images to TEM projection maps has allowed us to relate high magnification views obtained by AFM to the relatively high resolution information obtained by electron microscopy and image processing.

  11. 4D scanning transmission ultrafast electron microscopy: Single-particle imaging and spectroscopy.

    Science.gov (United States)

    Ortalan, Volkan; Zewail, Ahmed H

    2011-07-20

    We report the development of 4D scanning transmission ultrafast electron microscopy (ST-UEM). The method was demonstrated in the imaging of silver nanowires and gold nanoparticles. For the wire, the mechanical motion and shape morphological dynamics were imaged, and from the images we obtained the resonance frequency and the dephasing time of the motion. Moreover, we demonstrate here the simultaneous acquisition of dark-field images and electron energy loss spectra from a single gold nanoparticle, which is not possible with conventional methods. The local probing capabilities of ST-UEM open new avenues for probing dynamic processes, from single isolated to embedded nanostructures, without being affected by the heterogeneous processes of ensemble-averaged dynamics. Such methodology promises to have wide-ranging applications in materials science and in single-particle biological imaging.

  12. Image transfer with spatial coherence for aberration corrected transmission electron microscopes.

    Science.gov (United States)

    Hosokawa, Fumio; Sawada, Hidetaka; Shinkawa, Takao; Sannomiya, Takumi

    2016-08-01

    The formula of spatial coherence involving an aberration up to six-fold astigmatism is derived for aberration-corrected transmission electron microscopy. Transfer functions for linear imaging are calculated using the newly derived formula with several residual aberrations. Depending on the symmetry and origin of an aberration, the calculated transfer function shows characteristic symmetries. The aberrations that originate from the field's components, having uniformity along the z direction, namely, the n-fold astigmatism, show rotational symmetric damping of the coherence. The aberrations that originate from the field's derivatives with respect to z, such as coma, star, and three lobe, show non-rotational symmetric damping. It is confirmed that the odd-symmetric wave aberrations have influences on the attenuation of an image via spatial coherence. Examples of image simulations of haemoglobin and Si [211] are shown by using the spatial coherence for an aberration-corrected electron microscope.

  13. Characterization techniques for nano-electronics, with emphasis to electron microscopy. The role of the European Project ANNA

    Science.gov (United States)

    Armigliato, A.

    2008-07-01

    In the present and future CMOS technology, due to the ever shrinking geometries of the electronic devices, the availability of techniques capable of performing quantitative analyses of the relevant parameters (structural, chemical, mechanical) at a nanoscale is of a paramount importance. The influence of these features on the electrical performances of the nanodevices is a key issue for the nanoelectronics industry. In the recent years, a significant progress has been made in this field by a number of techniques, such as X-ray diffraction, in particular with the advent of synchrotron sources, ion-microbeam based Rutherford backscattering and channeling spectrometry, and micro Raman spectrometry. In addition, secondary ion mass spectrometry (SIMS) has achieved an important role in the determination of the dopant depth profile in ultra-shallow junctions (USJs) in silicon. However, the technique which features the ultimate spatial resolution (at the nanometer scale) is scanning transmission electron microscopy (STEM). In this presentation it will be reported on the nanoanalysis by STEM of two very important physical quantities which need to be controlled in the fabrication processes of nanodevices: the dopant profile in the USJs and the lattice strain that is generated in the Si electrically active regions of isolation structures by the different technological steps. The former quantity is investigated by the so-called Z-contrast high-angle annular dark field (HAADF-STEM) method, whereas the mechanical strain can be two-dimensionally mapped by the convergent beam electron diffraction (CBED-STEM) method. A spatial resolution lower than one nanometer and of a few nanometers can be achieved in the two cases, respectively. To keep the pace with the scientific and technological progress an increasingly wide array of analytical techniques is necessary; their complementary role in the solution of present and future characterization problems must be exploited. Presently

  14. Analiza tehnika upravljanja prenosom podataka / Analysis techniques for flow data transmission

    Directory of Open Access Journals (Sweden)

    Milojko Jevtović

    2006-01-01

    Full Text Available U članku su predstavljene ARQ tehnike za upravljanje prenosom i kontrolu na nivou veze: "Stani i čekaj", " Vrati se unazad za N" i "Selektivno odbacivanje ". Zatim je definisan važan parametar, kojim su analizirane osobine prenosa podataka na nivou veze i uprošćen prikaz karakteristika tehnika "Vrati se unazad za N" i "Selektivno odbacivanje". Osnovni cilj rada odnosi se na definisanje kriterijuma za izbor odgovarajućeg protokola upravljanja na nivou veze koji će zadovoljiti zahteve korisnika (gubici, kašnjenje, varijacija kašnjenja, propusna moć. Na osnovu urađene simulacije, korišćenjem programa MATLAB 7.0, izvršeno je upoređenje vrednosti parametara karakterističnih za navedene tehnike i izvedeni zaključci o prednostima i manama pojedinih tehnika. / This article presents ARQ techniques for flow and control at the link level: Stop-and-Wait, Go-back-N, and Selective-reject. Then it is defined an important parameter, necessary for analyzing characteristics of data transmission at the link level and simplified performances of the Go-back-N, and Selective-reject techniques. Main goal of this article refers to defining criteria for choosing proper protocol link control. By this criterion it is necessary to satisfy customer requirements like losses, delays, capacity, etc. By performing simulation (using MATLAB 7.0, comparison of the values of the techniques parameters is done and conclusions about advantages and disadvantages of certain techniques are given.

  15. Further Evaluation of the Neutron Resonance Transmission Analysis (NRTA) Technique for Assaying Plutonium in Spent Fuel

    Energy Technology Data Exchange (ETDEWEB)

    J. W. Sterbentz; D. L. Chichester

    2011-09-01

    This is an end-of-year report (Fiscal Year (FY) 2011) for the second year of effort on a project funded by the National Nuclear Security Administration's Office of Nuclear Safeguards (NA-241). The goal of this project is to investigate the feasibility of using Neutron Resonance Transmission Analysis (NRTA) to assay plutonium in commercial light-water-reactor spent fuel. This project is part of a larger research effort within the Next-Generation Safeguards Initiative (NGSI) to evaluate methods for assaying plutonium in spent fuel, the Plutonium Assay Challenge. The second-year goals for this project included: (1) assessing the neutron source strength needed for the NRTA technique, (2) estimating count times, (3) assessing the effect of temperature on the transmitted signal, (4) estimating plutonium content in a spent fuel assembly, (5) providing a preliminary assessment of the neutron detectors, and (6) documenting this work in an end of the year report (this report). Research teams at Los Alamos National Laboratory (LANL), Lawrence Berkeley National Laboratory (LBNL), Pacific Northwest National Laboratory (PNNL), and at several universities are also working to investigate plutonium assay methods for spent-fuel safeguards. While the NRTA technique is well proven in the scientific literature for assaying individual spent fuel pins, it is a newcomer to the current NGSI efforts studying Pu assay method techniques having just started in March 2010; several analytical techniques have been under investigation within this program for two to three years or more. This report summarizes work performed over a nine month period from January-September 2011 and is to be considered a follow-on or add-on report to our previous published summary report from December 2010 (INL/EXT-10-20620).

  16. Ultrastructural view of colon anastomosis under propolis effect by transmission electron microscopy

    Institute of Scientific and Technical Information of China (English)

    Sibel Serin Kilicoglu; Bulent Kilicoglu; Esra Erdemli

    2008-01-01

    AIM: To evaluate the effect of propolis administration on the healing of colon anastomosis with light and transmission electron microscopes.METHODS: Forty-eight Wistar-Albino female rats were divided into two groups and had colon resection and anastomosis.In group Ⅰ,rats were fed with standard rat chow pre- and postoperatively.The rats in group Ⅱ were fed with standard rat chow and began receiving oral supplementation of propolis 100 mg/kg per day beginning 7 d before the operation and continued until they were sacrificed.Rats were sacrificed 1,3,7 and 14 d after operation,and anastomotic bursting pressures measured.After the resection of anastomotic segments,histopathological examination was performed with light and transmission electron microscopes by two blinded histologists and photographed.RESULTS: The colonic bursting pressures of the propolis group were statistically significantly better than the control group.Ultrastructural histopathological analysis of the colon anastomosis revealed that propolis accelerated the phases of the healing process and stimulated mature granulation tissue formation and collagen synthesis of fibroblasts.CONCLUSION: Bursting pressure measurements and ultra structural histopathological evaluation showed that administration of propolis accelerated the healing of colon anastomosis following surgical excision.

  17. Transmission electron microscopy study of enterohemorrhagic Escherichia coli O157:H7 in apple tissue.

    Science.gov (United States)

    Janes, Marlene E; Kim, K S; Johnson, M G

    2005-02-01

    We investigated the ability of enterohemorrhagic Escherichia coli O157:H7 to spread in wounded apple tissue by transmission electron microscopy. Red Delicious apples were wounded with an artist knife (7 mm depth) and either inoculated with 10 microl per wound of decimally diluted E. coli O157:H7 or submerged into E. coli O157:H7 suspended in sterile distilled water and then stored at 37 degrees C for 24 h. Transmission electron microscopy showed E. coli O157:H7 formed bacterial aggregates near the apple cell walls, and single cells were in close proximity to the apple cell wall surfaces and to plasma membranes. E. coli O157:H7 presence caused degradation of plasma membranes and release of the cytoplasm contents of the apple cortical cells into the central vacuole. Apple tissue turgor pressure tests showed that the apple cells infected with E. coli O157:H7 isolates were more likely to rupture than the control noninoculated apple cells. E. coli O157:H7 cells grown in apple tissue showed the formation of granules and vesicles within the bacterial cytoplasma and separation of the plasma membranes. Our study shows that E. coli O157:H7 can grow and survive in the apple tissue environment by causing degradation of the apple cellular components.

  18. How to determine the morphology of plasmonic nanocrystals without transmission electron microscopy?

    Science.gov (United States)

    Battie, Yann; Izquierdo-Lorenzo, Irene; Resano-Garcia, Amandine; Naciri, Aotmane En; Akil, Suzanna; Adam, Pierre Michel; Jradi, Safi

    2016-08-01

    This paper reports the complete ellipsometric characterization of gold nanoparticles (NPs) embedded in a photoresist films. The effective dielectric function of nanocomposite films as well as the shape distribution and the volume fraction of NPs are extracted from ellipsometric measurements by introducing an effective medium theory which takes into account the NP shape distribution and the intrinsic confinement effect. This theory remains valid as long as the nanoparticle interaction is negligible. We show that the magnitude of the confinement depends on the nanoparticle shape and the environment through chemical damping. This suggests that the NP shape distribution can be directly estimated by ellipsometry, while the determination of absolute radius distribution requires transmission electron microscopy measurements. The imaginary part of the effective dielectric function exhibits a strong asymmetric surface plasmon band, while a large variation of the real part occurs close to the resonance. The redshift and the broadening of the plasmon band as the gold volume fraction increases are correlated to the evolution of NP shape distribution. This evolution is attributed to a competition between the nucleation and the coalescence of NPs. This unambiguously demonstrates that ellipsometry combined with a shape-distributed effective medium theory is a powerful alternative tool to transmission electron microscopy for the NP shape analysis.

  19. Electronic compensator for 100-Gb//s PDM-CO-OFDM long-haul transmission systems

    Institute of Scientific and Technical Information of China (English)

    Xuejun Liu; Yaojun Qiao; Yuefeng Ji

    2011-01-01

    @@ We study an electronic compensator (EC) as a receiver for a 100-Gb/s polarization division multiplexing coherent optical orthogonal frequency division multiplexing (PDM-CO-OFDM) system without optical dispersion compensation.EC, including electrical dispersion compensation (EDC), least squares channel estimation and compensation (LSCEC), and phase compensation (PC), is used to compensate for chromatic dispersion (CD), phase noise, polarization mode dispersion (PMD), and channel impairments, respectively.Simulations show that EC is highly effective in compensating for those impairments and that the performance is close to the theoretical limitation of optical signal-to-noise rate (OSNR), CD, and PMD.Its robustness against those transmission impairments and fiber nonlinearity are also systematically studied.%We study an electronic compensator (EC) as a receiver for a 100-Gb/s polarization division multiplexing coherent optical orthogonal frequency division multiplexing (PDM-CO-OFDM) system without optical dispersion compensation. EC, including electrical dispersion compensation (EDC), least squares channel estimation and compensation (LSCEC), and phase compensation (PC), is used to compensate for chromatic dispersion (CD), phase noise, polarization mode dispersion (PMD), and channel impairments,respectively. Simulations show that EC is highly effective in compensating for those impairments and that the performance is close to the theoretical limitation of optical signal-to-noise rate (OSNR), CD, and PMD. Its robustness against those transmission impairments and fiber nonlinearity are also systematically studied.

  20. The Probe Profile and Lateral Resolution of Scanning Transmission Electron Microscopy of Thick Specimens

    Science.gov (United States)

    Demers, Hendrix; Ramachandra, Ranjan; Drouin, Dominique; de Jonge, Niels

    2012-01-01

    Lateral profiles of the electron probe of scanning transmission electron microscopy (STEM) were simulated at different vertical positions in a micrometers-thick carbon sample. The simulations were carried out using the Monte Carlo method in the CASINO software. A model was developed to fit the probe profiles. The model consisted of the sum of a Gaussian function describing the central peak of the profile, and two exponential decay functions describing the tail of the profile. Calculations were performed to investigate the fraction of unscattered electrons as function of the vertical position of the probe in the sample. Line scans were also simulated over gold nanoparticles at the bottom of a carbon film to calculate the achievable resolution as function of the sample thickness and the number of electrons. The resolution was shown to be noise limited for film thicknesses less than 1 μm. Probe broadening limited the resolution for thicker films. The validity of the simulation method was verified by comparing simulated data with experimental data. The simulation method can be used as quantitative method to predict STEM performance or to interpret STEM images of thick specimens. PMID:22564444

  1. Fabrication of high-transmission microporous membranes by proton beam writing-based molding technique

    Science.gov (United States)

    Wang, Liping; Meyer, Clemens; Guibert, Edouard; Homsy, Alexandra; Whitlow, Harry J.

    2017-08-01

    Porous membranes are widely used as filters in a broad range of micro and nanofluidic applications, e.g. organelle sorters, permeable cell growth substrates, and plasma filtration. Conventional silicon fabrication approaches are not suitable for microporous membranes due to the low mechanical stability of thin film substrates. Other techniques like ion track etching are limited to the production of randomly distributed and randomly orientated pores with non-uniform pore sizes. In this project, we developed a procedure for fabricating high-transmission microporous membranes by proton beam writing (PBW) with a combination of spin-casting and soft lithography. In this approach, focused 2 MeV protons were used to lithographically write patterns consisting of hexagonal arrays of high-density pillars of few μm size in a SU-8 layer coated on a silicon wafer. After development, the pillars were conformably coated with a thin film of poly-para-xylylene (Parylene)-C release agent and spin-coated with polydimethylsiloxane (PDMS). To facilitate demolding, a special technique based on the use of a laser-cut sealing tape ring was developed. This method facilitated the successful delamination of 20-μm thick PDMS membrane with high-density micropores from the mold without rupture or damage.

  2. Visualization of Available Power Transfer Capability in a Transmission System Using Morphological Techniques

    Directory of Open Access Journals (Sweden)

    S. U. Prabha

    2009-01-01

    Full Text Available A morphological decimation technique has been proposed and implemented to analyze the available power transfer capability in a transmission power network. The method creates a graphical image of the power network with thickness of the lines proportional to their respective rated megavolt ampere (MVA capacity. Based on ac load flow solution, another image was created to represent the power flow in Megawatt (MW between the buses. Proper scaling procedure has been discussed for the construction of graphical images. The novelty of this research lies in the application of mathematical morphological techniques for decimating the created images. The image created for the MW capacities of the power lines were decimated into categories and grouped into different colors for better visualization. The multi-color image is superimposed on the input image which is created for the MVA capacity of the network. The proposed method has been tested on an IEEE test system. The results from the present approach can help the planner and operator in a power station, to get a better visualization of the power network. This is the first time this kind of multi-color visualization is presented and it can be used to find the optimal path for power transfer from one bus to another.

  3. Microwave properties of monolithic Y-Ba-Cu-O transmission line devices fabricated by the laser-writing patterning technique

    Energy Technology Data Exchange (ETDEWEB)

    Maung, W.N.; Butler, D.P. [Southern Methodist Univ., Dallas, TX (United States). Electrical Engineering Dept.; Xiong, W. [Univ. of Rochester, NY (United States). Dept. of Electrical Engineering; Kula, W.; Sobolewski, R. [Univ. of Rochester, NY (United States). Dept. of Electrical Engineering]|[Polish Academy of Sciences, Warszawa (Poland). Inst. of Physics

    1994-12-31

    The authors report on the microwave characteristics of coplanar strip transmission line devices fabricated in epitaxial YBaCuO thin films deposited on LaAlO{sub 3} substrates using the novel laser-writing patterning technique. This technique uses laser heating to selectively anneal regions of an oxygen depleted YBaCuO thin film to form local superconducting phases. In this manner, superconductive coplanar strip transmission line structures surrounded by the semiconducting YBaCuO phase were patterned with no photomasks, surface contamination or edge degradation. The propagation characteristics of transmission line devices were measured with a HP8510 network analyzer from 1 to 20 GHz. At 300 K, the transmission line circuits displayed poor transmission characteristics due to the high conductivity of the semiconducting phase and small conductivity enhancement of the oxygenated regions. As the circuits were cooled below 89 K, the {Tc} of the superconducting phase, the measured S{sub 21} was near 0 dB indicating little attenuation along the high quality transmission lines. Q-factors as high as 5,000 were measured from coplanar strip transmission line resonator circuits at 6 GHz and 24 K.

  4. Biological Applications and Transmission Electron Microscopy Investigations of Mesoporous Silica Nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Trewyn, Brian G. [Iowa State Univ., Ames, IA (United States)

    2006-01-01

    The research presented and discussed within involves the development of novel biological applications of mesoporous silica nanoparticles (MSN) and an investigation of mesoporous material by transmission electron microscopy (TEM). Mesoporous silica nanoparticles organically functionalized shown to undergo endocytosis in cancer cells and drug release from the pores was controlled intracellularly and intercellularly. Transmission electron microscopy investigations demonstrated the variety of morphologies produced in this field of mesoporous silica nanomaterial synthesis. A series of room-temperature ionic liquid (RTIL) containing mesoporous silica nanoparticle (MSN) materials with various particle morphologies, including spheres, ellipsoids, rods, and tubes, were synthesized. By changing the RTIL template, the pore morphology was tuned from the MCM-41 type of hexagonal mesopores to rotational moire type of helical channels, and to wormhole-like porous structures. These materials were used as controlled release delivery nanodevices to deliver antibacterial ionic liquids against Escherichia coli K12. The involvement of a specific organosiloxane function group, covalently attached to the exterior of fluorescein doped mesoporous silica nanoparticles (FITC-MSN), on the degree and kinetics of endocytosis in cancer and plant cells was investigated. The kinetics of endocystosis of TEG coated FITC-MSN is significantly quicker than FITC-MSN as determined by flow cytometry experiments. The fluorescence confocal microscopy investigation showed the endocytosis of TEG coated-FITC MSN triethylene glycol grafted fluorescein doped MSN (TEG coated-FITC MSN) into both KeLa cells and Tobacco root protoplasts. Once the synthesis of a controlled-release delivery system based on MCM-41-type mesoporous silica nanorods capped by disulfide bonds with superparamagnetic iron oxide nanoparticles was completed. The material was characterized by general methods and the dosage and kinetics of the

  5. Supplementary examination of alternative materials in a model steam generator: Volume 3, tube characterization by metallography and transmission electron microscopy: Final report

    Energy Technology Data Exchange (ETDEWEB)

    Krupowicz, J.J.; Stubbins, J.F.; Mehler, M.

    1988-10-01

    The microstructural characteristics of current and candidate alloys for steam generator heat transfer tubing were determined utilizing a variety of techniques. Mill annealed heats of Alloys 690 and 800NG were examined as well as heats of Alloy 600 in the mill annealed, process stabilized, sensitized and thermally treated conditions. Characterization included optical microscopy, transmission electron microscopy and scanning transmission electron microscopy of these materials in their pre- and post-test conditions (i.e., archive and exposure for 11,328 hours to 621/degree/F primary temperature). The results were utilized to elicit comparisons of these materials to stress corrosion cracking resistance in sulfate faulted secondary environments. 83 figs., 8 tabs.

  6. 2D atomic mapping of oxidation states in transition metal oxides by scanning transmission electron microscopy and electron energy-loss spectroscopy

    OpenAIRE

    Tan, H.; Turner, S.; Yücelen, E.; Verbeeck, J.; Van Tendeloo, G.

    2011-01-01

    Abstract: Using a combination of high-angle annular dark-field scanning transmission electron microscopy and atomically resolved electron energy-loss spectroscopy in an aberration-corrected transmission electron microscope we demonstrate the possibility of 2D atom by atom valence mapping in the mixed valence compound Mn3O4. The Mn L2,3 energy-loss near-edge structures from Mn2+ and Mn3+ cation sites are similar to those of MnO and Mn2O3 references. Comparison with simulations shows that even ...

  7. Novel production techniques of radioisotopes using electron accelerators

    Science.gov (United States)

    Lowe, Daniel Robert

    Non-traditional radioisotope production techniques using a compact, high power linear electron accelerator have been demonstrated and characterized for the production of 18F, 47Sc, 147 Pm, and 99mTc from a variety of target candidates. These isotopes are used extensively in the medical field as diagnostic and therapy radioisotopes, as well as the space industry as RTG's. Primary focus was placed on 99mTc as it constitutes approximately 80% of all diagnostic procedures in the medical community that use radioactive tracers. It was also the prime focus due to recent events at the Chalk River nuclear reactor, which caused global shortages of this isotope a few years ago. A Varian K15 LINAC was first used to show proof of principle in Las Vegas. Various samples were then taken to the Idaho Accelerator Center where they were activated using an electron LINAC capable of electron energies from 4 to 25 MeV at a beam power of approximately 1 kW. Production rates, cross sections, and viability studies were then performed and conducted to assess the effectiveness of the candidate target and the maximum production rate for each radioisotope. Production rates for 18F from lithium fluoride salts were shown to be ideal at 21MeV, namely 1.7 Ci per kg of LiF salt, per kW of beam current, per 10 hour irradiation time. As the typical hospital consumption of 18F is around 500 mCi per day, it is clear that a large amount of 18F can be made from a small (300 gram) sample of LiF salt. However, since there is no current separation process for 18F from 19F, the viability of this technique is limited until a separations technique is developed. Furthermore, the calculated cross section for this reaction is in good agreement with literature, which supports the techniques for the isotopes mentioned below. Production rates for 47Sc from vanadium oxide targets were shown to be a maximum at 25 MeV with a production rate of 2 mCi per day, assuming a 2 kW beam and a 10 kg target. While this

  8. Manipulation and in situ transmission electron microscope characterization of sub-100 nm nanostructures using a microfabricated nanogripper

    DEFF Research Database (Denmark)

    Cagliani, Alberto; Wierzbicki, Rafal; Occhipini, Luigi

    2010-01-01

    of electron beam lithography. Vertically grown III–V nanowires with a diameter of 70 nm were picked up using the nanogripper, allowing direct transfer of the nanogripper-nanowire ensemble into a transmission electron microscope (TEM) for structural characterization. By refining the end-effectors with focused...

  9. A Novel Noise Free Transmission Technique for Designing 100Gb/s Future Generation Optical Communication System

    DEFF Research Database (Denmark)

    Das, Bhagwan; Abdullah, M.F.L.; Pandey, Bishwajeet

    2017-01-01

    Differential Phase Shift Keying (DPSK) techniques are widely used in designing the high-speed communication systems. However, these techniques still need improvement for long haul communication system design. In this paper, high-speed optical signal transmission and reception system is achieved f...... the transmission and reception of data for high-speed long haul communication system without using any amplifier or repeater.......Differential Phase Shift Keying (DPSK) techniques are widely used in designing the high-speed communication systems. However, these techniques still need improvement for long haul communication system design. In this paper, high-speed optical signal transmission and reception system is achieved...... that BER of 10-12+, Q-factor 98 at power penalty of 14 dB is attained using the designed technique for transmitting 100Gb/s at 300 Km. Whereas, existing NRZ technique achieved a BER of 10-6, Q-factor 32 at power penalty of 11 dB for same similar transmission data rate and distance. The designed offers...

  10. Face Recognition as an Authentication Technique in Electronic Voting

    Directory of Open Access Journals (Sweden)

    Noha E. El-Sayad

    2013-07-01

    Full Text Available In this research a Face Detection and Recognition system (FDR used as an Authentication technique in online voting, which one of electronic is voting types, is proposed. Web based voting allows the voter to vote from any place in state or out of state. The voter’s image is captured and passed to a face detection algorithm (Eigenface or Gabor filter which is used to detect his face from the image and save it as the first matching point. The voter’s National identification card number is used to retrieve and return his saved photo from the database of the Supreme Council elections (SCE which is passed to the same detection algorithm (Eigenface or Gabor filter to detect face from it and save it as second matching point. The two matching points are used by a matching algorithm to check wither they are identical or not. If the results of the matching algorithm are two point match then checks wither this person has the right to vote or not. If he has right to vote then a voting form is presented to him. The result shows that the proposed algorithm capable of finding over 90% of the faces in database and allows their voter to vote in approximately 58 seconds.

  11. Automated twin identification technique for use with electron backscatter diffraction.

    Energy Technology Data Exchange (ETDEWEB)

    Henrie, B. L. (Benjamin Lyman); Mason, T. A. (Thomas A.); Bingert, J. F. (John F.)

    2004-01-01

    Historically, twinning information has been obtained by optical microscopy, TEM, and neutron diffraction. Recent research has shown that automated electron backscatter diffraction (EBSD) can be used to extract reliable twinning statistics. An automated twin identification technique for use with EBSD has facilitated a greater understanding of deformation twinning in materials. The key features of this automated framework are the use of the crystallographic definition of twin relationships, the inclination of the common K, plane at a twin boundary, and the correct identification of the parent orientation in a parent/twin pair. The complex nature of the parent/twin interactions required the use of a voting scheme to correctly identify parent orientations. In those few cases were the voting scheme was unable to determine parent orientation (< 2 pct) the algorithm allows for manual selection. Twin area fractions are categorized by operative twin systems along with secondary and tertiary twinning. These statistics are reported for {alpha}-zirconium and 316L stainless steel. These improved twin statistics can help quantify deformation processes as well as provide validation of plasticity models for materials that exhibit deformation twinning.

  12. Preparation of cultured cells using high-pressure freezing and freeze substitution for subsequent 2D or 3D visualization in the transmission electron microscope.

    Science.gov (United States)

    Hawes, Philippa C

    2015-01-01

    Transmission electron microscopy (TEM) is an invaluable technique used for imaging the ultrastructure of samples and it is particularly useful when determining virus-host interactions at a cellular level. The environment inside a TEM is not favorable for biological material (high vacuum and high energy electrons). Also biological samples have little or no intrinsic electron contrast, and rarely do they naturally exist in very thin sheets, as is required for optimum resolution in the TEM. To prepare these samples for imaging in the TEM therefore requires extensive processing which can alter the ultrastructure of the material. Here we describe a method which aims to minimize preparation artifacts by freezing the samples at high pressure to instantaneously preserve ultrastructural detail, then rapidly substituting the ice and infiltrating with resin to provide a firm matrix which can be cut into thin sections for imaging. Thicker sections of this material can also be imaged and reconstructed into 3D volumes using electron tomography.

  13. In-situ Study of Dynamic Phenomena at Metal Nanosolder Interfaces Using Aberration Corrected Scanning Transmission Electron Microcopy.

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Ping

    2014-10-01

    Controlling metallic nanoparticle (NP) interactions plays a vital role in the development of new joining techniques (nanosolder) that bond at lower processing temperatures but remain viable at higher temperatures. The pr imary objective of this project is t o develop a fundamental understanding of the actual reaction processes, associated atomic mechanisms, and the resulting microstructure that occur during thermally - driven bond formation concerning metal - metal nano - scale (%3C50nm) interfaces. In this LDRD pr oject, we have studied metallic NPs interaction at the elevated temperatures by combining in - situ transmission electron microscopy (TEM ) using an aberration - corrected scanning transmission electron microscope (AC - STEM) and atomic - scale modeling such as m olecular dynamic (MD) simulations. Various metallic NPs such as Ag, Cu and Au are synthesized by chemical routines. Numerous in - situ e xperiments were carried out with focus of the research on study of Ag - Cu system. For the first time, using in - situ STEM he ating experiments , we directly observed t he formation of a 3 - dimensional (3 - D) epitaxial Cu - Ag core - shell nanoparticle during the thermal interaction of Cu and Ag NPs at elevated temperatures (150 - 300 o C). The reaction takes place at temperatures as low as 150 o C and was only observed when care was taken to circumvent the effects of electron beam irradiation during STEM imaging. Atomic - scale modeling verified that the Cu - Ag core - shell structure is energetically favored, and indicated that this phenomenon is a nano - scale effect related to the large surface - to - volume ratio of the NPs. The observation potentially can be used for developing new nanosolder technology that uses Ag shell as the "glue" that stic ks the particles of Cu together. The LDRD has led to several journal publications and numerous conference presentations, and a TA. In addition, we have developed new TEM characterization techniques and phase

  14. Ultrastructural Identification and Colocalization of Interacting Proteins in the Murine Cochlea by Post-Embedding Immunogold Transmission Electron Microscopy.

    Science.gov (United States)

    Harvey, Margaret C; Sokolowski, Bernd H A

    2016-01-01

    Verification of the presence and location of a protein within tissue can be accomplished by western blotting and immunohistochemistry, using either paraffin or frozen sections. Affinity purification by reciprocal coimmunoprecipitations using the tissue of interest can demonstrate the existence of an interacting pair of proteins. Ultimately, the ability to visualize the interaction at the cellular level is desired. Precise location(s) of interacting proteins in situ can be accomplished by ultrastructural localization with high-quality primary antibodies and small-particle-size Au-conjugated secondary antibodies. Visualization can be obtained with a transmission electron microscope fitted with a high-resolution camera permitting magnifications that exceed 2 × 10(5), and, to date, resolution capability of 20+ Mpixels, thus enabling localization of the target protein to within nanometers of the actual location. Here, we report the method by which immunolocalization at the level of the electron microscope is accomplished using the post-embedding technique, i.e., performing antibody labeling of proteins on ultrathin sections of tissue embedded in acrylic resin.

  15. Experimental Investigation of Space Radiation Processing in Lunar Soil Ilmenite: Combining Perspectives from Surface Science and Transmission Electron Microscopy

    Science.gov (United States)

    Christoffersen, R.; Keller, L. P.; Rahman, Z.; Baragiola, R.

    2010-01-01

    Energetic ions mostly from the solar wind play a major role in lunar space weathering because they contribute structural and chemical changes to the space-exposed surfaces of lunar regolith grains. In mature mare soils, ilmenite (FeTiO3) grains in the finest size fraction have been shown in transmission electron microscope (TEM) studies to exhibit key differences in their response to space radiation processing relative to silicates [1,2,3]. In ilmenite, solar ion radiation alters host grain outer margins to produce 10-100 nm thick layers that are microstructurally complex, but dominantly crystalline compared to the amorphous radiation-processed rims on silicates [1,2,3]. Spatially well-resolved analytical TEM measurements also show nm-scale compositional and chemical state changes in these layers [1,3]. These include shifts in Fe/Ti ratio from strong surface Fe-enrichment (Fe/Ti >> 1), to Fe depletion (Fe/Ti electron (FE-STEM) study of experimentally ion-irradiated ilmenite. A key feature of this work is the combination of analytical techniques sensitive to changes in the irradiated samples at depth scales going from the immediate surface (approx.5 nm; XPS), to deeper in the grain interior (5-100 nm; FE-STEM).

  16. Transmission electron microscopy study of as-grown MgB{sub 2} films

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, T. [Graduate School of Engineering, Iwate University, 4-3-5 Ueda, Morioka 020-8551 (Japan); Harada, Y. [Iwate Industry Promotion Center, 3-35-2 Iioka-shinden, Morioka 020-0852 (Japan)]. E-mail: yharada@luck.ocn.ne.jp; Iriuda, H. [Graduate School of Engineering, Iwate University, 4-3-5 Ueda, Morioka 020-8551 (Japan); Kuroha, M. [Graduate School of Engineering, Iwate University, 4-3-5 Ueda, Morioka 020-8551 (Japan); Oba, T. [Faculty of Materials science and Engineering, Iwate University, 4-3-5 Ueda, Morioka 020-8551 (Japan); Seki, M. [Faculty of Materials science and Engineering, Iwate University, 4-3-5 Ueda, Morioka 020-8551 (Japan); Nakanishi, Y. [Graduate School of Engineering, Iwate University, 4-3-5 Ueda, Morioka 020-8551 (Japan); Echigoya, J. [Faculty of Materials science and Engineering, Iwate University, 4-3-5 Ueda, Morioka 020-8551 (Japan); Yoshizawa, M. [Graduate School of Engineering, Iwate University, 4-3-5 Ueda, Morioka 020-8551 (Japan)

    2006-10-01

    The intermetallic superconductor magnesium diboride (MgB{sub 2}) is a promising candidate for use in superconducting electronic devices because of its high transition temperature (T{sub c}). These applications require the development of a high-quality film fabrication process. We have previously reported the growth of MgB{sub 2} films deposited on MgO (1 0 0), SrTiO{sub 3} (1 0 0) and Al{sub 2}O{sub 3} (0 0 0 1) substrate using a co-evaporation method and molecular beam epitaxy (MBE) apparatus. In this paper, we will report the correlation between structural properties and physical properties of as-grown MgB{sub 2} films deposited on MgO (1 0 0), ZnO (0 0 0 1), and Si (1 1 1) substrate. The films' basal properties have been confirmed by reflection high-energy electron diffraction (RHEED), X-ray diffraction (XRD), resistivity measurements and SQUID magnetometry. The details of the interfacial structure were studied by transmission electron microscopy (TEM). We will then discuss the most important parameters for fabricating high quality as-grown MgB{sub 2} films and junctions.

  17. Transmission electron microscopy for the evaluation and optimization of crystal growth

    Energy Technology Data Exchange (ETDEWEB)

    Stevenson, Hilary P.; Lin, Guowu; Barnes, Christopher O.; Sutkeviciute, Ieva; Krzysiak, Troy; Weiss, Simon C.; Reynolds, Shelley; Wu, Ying; Nagarajan, Veeranagu; Makhov, Alexander M.; Lawrence, Robert; Lamm, Emily; Clark, Lisa; Gardella, Timothy J.; Hogue, Brenda G.; Ogata, Craig M.; Ahn, Jinwoo; Gronenborn, Angela M.; Conway, James F.; Vilardaga, Jean-Pierre; Cohen, Aina E.; Calero, Guillermo

    2016-04-26

    The crystallization of protein samples remains the most significant challenge in structure determination by X-ray crystallography. Here, the effectiveness of transmission electron microscopy (TEM) analysis to aid in the crystallization of biological macromolecules is demonstrated. It was found that the presence of well ordered lattices with higher order Bragg spots, revealed by Fourier analysis of TEM images, is a good predictor of diffraction-quality crystals. Moreover, the use of TEM allowed (i) comparison of lattice quality among crystals from different conditions in crystallization screens; (ii) the detection of crystal pathologies that could contribute to poor X-ray diffraction, including crystal lattice defects, anisotropic diffraction and crystal contamination by heavy protein aggregates and nanocrystal nuclei; (iii) the qualitative estimation of crystal solvent content to explore the effect of lattice dehydration on diffraction and (iv) the selection of high-quality crystal fragments for microseeding experiments to generate reproducibly larger sized crystals. Applications to X-ray free-electron laser (XFEL) and micro-electron diffraction (microED) experiments are also discussed.

  18. Transmission electron microscopic evaluation of neuronal changes in methylmercury-exposed zebrafish embryos (Danio rerio).

    Science.gov (United States)

    Hassan, Said A; Farouk, Sameh M; Abbott, Louise C

    2016-01-01

    Our work aimed to elucidate the ultrastructural changes associated with brain neurons in wild-type zebrafish embryos exposed to different concentrations of methylmercury. Zebrafish embryos were exposed to one of five concentrations of methylmercury (0 [negative control], 5, 10, 50, and 80 parts per billion) starting at six hours post fertilization (hpf). At 96 hpf, cells in the zebrafish embryo brains were examined using transmission electron microscopy. The developing neurons of the control embryos sowed normal cellular ultrastructure. Few alterations were observed among the neurons of zebrafish embryos exposed to 5 ppb methylmercury. The cells of the embryos exposed to 10 ppb methylmercury showed slight cellular degeneration as demonstrated by the accumulation of electron dens bodies which were presumably lysosomes in different stages of formation. In embryos exposed to 50 ppb methylmercury, the neuronal cytoplasm conained large electron dense lysosomes and the rough endoplasmic reticulum appeared to be reduced and irregular in shape. Furthermore, the embryonic brain neurons exposed to 80 ppb methylmercury showed the most severe ultrastructural changes, including some that were consistent with different stages of the cell death process. Obvious cellular changes were observed in this highest exposure group included: disrupted or degenerating nuclei; fragmentation or vacuolization of mitochondrial cristae; and loss of mitochondrial matrix density. Based on these observations, we conclude that these different morphological patterns of cellular changes may reflect either different stages of the cell death process or different types of cell death due to 24 hours of exposure to 80 ppb methylmercury.

  19. Measured Radiation and Background Levels During Transmission of Megawatt Electron Beams Through Millimeter Apertures

    Energy Technology Data Exchange (ETDEWEB)

    Alarcon, Ricardo [Arizona State University, Glendale, AZ (United States); Balascuta, S. [Arizona State University, Glendale, AZ (United States); Benson, Stephen V. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Bertozzi, William [Massachusetts Institute of Technology, Cambridge, MA (United States); Boyce, James R. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Cowan, Ray [Massachusetts Institute of Technology, Cambridge, MA (United States); Douglas, David R. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Evtushenko, Pavel [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Fisher, P. [Massachusetts Institute of Technology, Cambridge, MA (United States); Ihloff, Ernest E. [Hampton University, Hampton, VA (United States); Kalantarians, Narbe [Hampton University, Hampton, VA (United States); Kelleher, Aidan Michael [Massachusetts Institute of Technology, Cambridge, MA (United States); Krossler, W. J. [William and Mary College, Williamsburg, VA (United States); Legg, Robert A. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Long, Elena [University of New Hampshire, Durham, NH (United States); Milner, Richard [Massachusetts Institute of Technology, Cambridge, MA (United States); Neil, George R. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Ou, Longwu [Massachusetts Institute of Technology, Cambridge, MA (United States); Schmookler, Barack Abraham [Massachusetts Institute of Technology, Cambridge, MA (United States); Tennant, Christopher D. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Tschalar, C. [Massachusetts Institute of Technology, Cambridge, MA (United States); Williams, Gwyn P. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Zhang, Shukui [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States)

    2013-11-01

    We report measurements of photon and neutron radiation levels observed while transmitting a 0.43 MW electron beam through millimeter-sized apertures and during beam-off, but accelerating gradient RF-on, operation. These measurements were conducted at the Free-Electron Laser (FEL) facility of the Jefferson National Accelerator Laboratory (JLab) using a 100 MeV electron beam from an energy-recovery linear accelerator. The beam was directed successively through 6 mm, 4 mm, and 2 mm diameter apertures of length 127 mm in aluminum at a maximum current of 4.3 mA (430 kW beam power). This study was conducted to characterize radiation levels for experiments that need to operate in this environment, such as the proposed DarkLight Experiment. We find that sustained transmission of a 430 kW continuous-wave (CW) beam through a 2 mm aperture is feasible with manageable beam-related backgrounds. We also find that during beam-off, RF-on operation, multipactoring inside the niobium cavities of the accelerator cryomodules is the primary source of ambient radiation when the machine is tuned for 130 MeV operation.

  20. Practical Approaches to Mitigation of Specimen Charging in High-Resolution Transmission Electron Microscopy

    Directory of Open Access Journals (Sweden)

    Young-Min Kim

    2010-09-01

    Full Text Available Specimen charging that is associated with the electron bombardment on the sample is a practical hindrance to high-resolution transmission electron microscopy (HRTEM analysis because it causes a severe loss of resolution in either diffraction or image data. Conductive thin film deposition on an insulating specimen has been proposed as an effective approach to the mitigation of the specimen charging; however, this method is generally not useful in HRTEM imaging of materials because the deposited film induces another artifact in the HRTEM image contrast. In this study, we propose practical methods to mitigate the specimen charging that takes place during the HRTEM of materials. For bulk-type specimens prepared by either an ion-thinning or focused-ion beam (FIB process, a plasma cleaning treatment is significantly effective in eliminating the charging phenomenon. In the case of low-dimensional nanomaterials such as nanowires and nanoparticles, the plasma cleaning is not feasible; however, the charging effect can be effectively eliminated by adjusting the electron illumination condition. The proposed methods facilitate a decrease in the buildup of specimen charging, thereby enhancing the quality of high-resolution images significantly.