WorldWideScience

Sample records for technical inter-instrument variability

  1. Variations of Histone Modification Patterns: Contributions of Inter-plant Variability and Technical Factors

    Directory of Open Access Journals (Sweden)

    Sylva Brabencová

    2017-12-01

    Full Text Available Inter-individual variability of conspecific plants is governed by differences in their genetically determined growth and development traits, environmental conditions, and adaptive responses under epigenetic control involving histone post-translational modifications. The apparent variability in histone modifications among plants might be increased by technical variation introduced in sample processing during epigenetic analyses. Thus, to detect true variations in epigenetic histone patterns associated with given factors, the basal variability among samples that is not associated with them must be estimated. To improve knowledge of relative contribution of biological and technical variation, mass spectrometry was used to examine histone modification patterns (acetylation and methylation among Arabidopsis thaliana plants of ecotypes Columbia 0 (Col-0 and Wassilewskija (Ws homogenized by two techniques (grinding in a cryomill or with a mortar and pestle. We found little difference in histone modification profiles between the ecotypes. However, in comparison of the biological and technical components of variability, we found consistently higher inter-individual variability in histone mark levels among Ws plants than among Col-0 plants (grown from seeds collected either from single plants or sets of plants. Thus, more replicates of Ws would be needed for rigorous analysis of epigenetic marks. Regarding technical variability, the cryomill introduced detectably more heterogeneity in the data than the mortar and pestle treatment, but mass spectrometric analyses had minor apparent effects. Our study shows that it is essential to consider inter-sample variance and estimate suitable numbers of biological replicates for statistical analysis for each studied organism when investigating changes in epigenetic histone profiles.

  2. Variations of Histone Modification Patterns: Contributions of Inter-plant Variability and Technical Factors.

    Science.gov (United States)

    Brabencová, Sylva; Ihnatová, Ivana; Potěšil, David; Fojtová, Miloslava; Fajkus, Jiří; Zdráhal, Zbyněk; Lochmanová, Gabriela

    2017-01-01

    Inter-individual variability of conspecific plants is governed by differences in their genetically determined growth and development traits, environmental conditions, and adaptive responses under epigenetic control involving histone post-translational modifications. The apparent variability in histone modifications among plants might be increased by technical variation introduced in sample processing during epigenetic analyses. Thus, to detect true variations in epigenetic histone patterns associated with given factors, the basal variability among samples that is not associated with them must be estimated. To improve knowledge of relative contribution of biological and technical variation, mass spectrometry was used to examine histone modification patterns (acetylation and methylation) among Arabidopsis thaliana plants of ecotypes Columbia 0 (Col-0) and Wassilewskija (Ws) homogenized by two techniques (grinding in a cryomill or with a mortar and pestle). We found little difference in histone modification profiles between the ecotypes. However, in comparison of the biological and technical components of variability, we found consistently higher inter-individual variability in histone mark levels among Ws plants than among Col-0 plants (grown from seeds collected either from single plants or sets of plants). Thus, more replicates of Ws would be needed for rigorous analysis of epigenetic marks. Regarding technical variability, the cryomill introduced detectably more heterogeneity in the data than the mortar and pestle treatment, but mass spectrometric analyses had minor apparent effects. Our study shows that it is essential to consider inter-sample variance and estimate suitable numbers of biological replicates for statistical analysis for each studied organism when investigating changes in epigenetic histone profiles.

  3. Unit-specific calibration of Actigraph accelerometers in a mechanical setup - is it worth the effort? The effect on random output variation caused by technical inter-instrument variability in the laboratory and in the field

    DEFF Research Database (Denmark)

    Moeller, Niels C; Korsholm, Lars; Kristensen, Peter L

    2008-01-01

    BACKGROUND: Potentially, unit-specific in-vitro calibration of accelerometers could increase field data quality and study power. However, reduced inter-unit variability would only be important if random instrument variability contributes considerably to the total variation in field data. Therefor...

  4. Impact of Reconstruction Algorithms on CT Radiomic Features of Pulmonary Tumors: Analysis of Intra- and Inter-Reader Variability and Inter-Reconstruction Algorithm Variability.

    Science.gov (United States)

    Kim, Hyungjin; Park, Chang Min; Lee, Myunghee; Park, Sang Joon; Song, Yong Sub; Lee, Jong Hyuk; Hwang, Eui Jin; Goo, Jin Mo

    2016-01-01

    To identify the impact of reconstruction algorithms on CT radiomic features of pulmonary tumors and to reveal and compare the intra- and inter-reader and inter-reconstruction algorithm variability of each feature. Forty-two patients (M:F = 19:23; mean age, 60.43±10.56 years) with 42 pulmonary tumors (22.56±8.51mm) underwent contrast-enhanced CT scans, which were reconstructed with filtered back projection and commercial iterative reconstruction algorithm (level 3 and 5). Two readers independently segmented the whole tumor volume. Fifteen radiomic features were extracted and compared among reconstruction algorithms. Intra- and inter-reader variability and inter-reconstruction algorithm variability were calculated using coefficients of variation (CVs) and then compared. Among the 15 features, 5 first-order tumor intensity features and 4 gray level co-occurrence matrix (GLCM)-based features showed significant differences (palgorithms. As for the variability, effective diameter, sphericity, entropy, and GLCM entropy were the most robust features (CV≤5%). Inter-reader variability was larger than intra-reader or inter-reconstruction algorithm variability in 9 features. However, for entropy, homogeneity, and 4 GLCM-based features, inter-reconstruction algorithm variability was significantly greater than inter-reader variability (palgorithms. Inter-reconstruction algorithm variability was greater than inter-reader variability for entropy, homogeneity, and GLCM-based features.

  5. Development of an inter-professional screening instrument for cancer patients' education process.

    Science.gov (United States)

    Vaartio-Rajalin, Heli; Huumonen, Tuula; Iire, Liisa; Jekunen, Antti; Leino-Kilpi, Helena; Minn, Heikki; Paloniemi, Jenni; Zabalegui, Adelaida

    2016-02-01

    The aim of this paper is to describe the development of an inter-professional screening instrument for cancer patients' cognitive resources, knowledge expectations and inter-professional collaboration within patient education. Four empirical datasets during 2012-2014 were analyzed in order to identify main categories, subcategories and items for inter-professional screening instrument. Our inter-professional screening instrument integrates the critical moments of cancer patient education and the knowledge expectation types obtained from patient datasets to assessment of patients' cognitive resources, knowledge expectations and comprehension; and intra; and inter-professional. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. INTER-EXAMINER VARIABILITY

    African Journals Online (AJOL)

    Objective: To establish whether inter-examiner variability is still a significant factor for the undergraduate orthopaedic clinical ... D. The scores for each student were tabulated and the range, mean, and pass rate determined for each of the examiners. ... has not the heart to reject the man”, consistently gave higher scores (1).

  7. Quantifying inter-laboratory variability in stable isotope analysis of ancient skeletal remains.

    Directory of Open Access Journals (Sweden)

    William J Pestle

    Full Text Available Over the past forty years, stable isotope analysis of bone (and tooth collagen and hydroxyapatite has become a mainstay of archaeological and paleoanthropological reconstructions of paleodiet and paleoenvironment. Despite this method's frequent use across anthropological subdisciplines (and beyond, the present work represents the first attempt at gauging the effects of inter-laboratory variability engendered by differences in a sample preparation, and b analysis (instrumentation, working standards, and data calibration. Replicate analyses of a 14C-dated ancient human bone by twenty-one archaeological and paleoecological stable isotope laboratories revealed significant inter-laboratory isotopic variation for both collagen and carbonate. For bone collagen, we found a sizeable range of 1.8‰ for δ13Ccol and 1.9‰ for δ15Ncol among laboratories, but an interpretatively insignificant average pairwise difference of 0.2‰ and 0.4‰ for δ13Ccol and δ15Ncol respectively. For bone hydroxyapatite the observed range increased to a troublingly large 3.5‰ for δ13Cap and 6.7‰ for δ18Oap, with average pairwise differences of 0.6‰ for δ13Cap and a disquieting 2.0‰ for δ18Oap. In order to assess the effects of preparation versus analysis on isotopic variability among laboratories, a subset of the samples prepared by the participating laboratories were analyzed a second time on the same instrument. Based on this duplicate analysis, it was determined that roughly half of the isotopic variability among laboratories could be attributed to differences in sample preparation, with the other half resulting from differences in analysis (instrumentation, working standards, and data calibration. These findings have serious implications for choices made in the preparation and extraction of target biomolecules, the comparison of results obtained from different laboratories, and the interpretation of small differences in bone collagen and hydroxyapatite

  8. Quantifying inter-laboratory variability in stable isotope analysis of ancient skeletal remains.

    Science.gov (United States)

    Pestle, William J; Crowley, Brooke E; Weirauch, Matthew T

    2014-01-01

    Over the past forty years, stable isotope analysis of bone (and tooth) collagen and hydroxyapatite has become a mainstay of archaeological and paleoanthropological reconstructions of paleodiet and paleoenvironment. Despite this method's frequent use across anthropological subdisciplines (and beyond), the present work represents the first attempt at gauging the effects of inter-laboratory variability engendered by differences in a) sample preparation, and b) analysis (instrumentation, working standards, and data calibration). Replicate analyses of a 14C-dated ancient human bone by twenty-one archaeological and paleoecological stable isotope laboratories revealed significant inter-laboratory isotopic variation for both collagen and carbonate. For bone collagen, we found a sizeable range of 1.8‰ for δ13Ccol and 1.9‰ for δ15Ncol among laboratories, but an interpretatively insignificant average pairwise difference of 0.2‰ and 0.4‰ for δ13Ccol and δ15Ncol respectively. For bone hydroxyapatite the observed range increased to a troublingly large 3.5‰ for δ13Cap and 6.7‰ for δ18Oap, with average pairwise differences of 0.6‰ for δ13Cap and a disquieting 2.0‰ for δ18Oap. In order to assess the effects of preparation versus analysis on isotopic variability among laboratories, a subset of the samples prepared by the participating laboratories were analyzed a second time on the same instrument. Based on this duplicate analysis, it was determined that roughly half of the isotopic variability among laboratories could be attributed to differences in sample preparation, with the other half resulting from differences in analysis (instrumentation, working standards, and data calibration). These findings have serious implications for choices made in the preparation and extraction of target biomolecules, the comparison of results obtained from different laboratories, and the interpretation of small differences in bone collagen and hydroxyapatite isotope values

  9. Inter-observer and inter-examination variability of manual vertebral bone attenuation measurements on computed tomography

    International Nuclear Information System (INIS)

    Pompe, Esther; Lammers, Jan-Willem J.; Jong, Pim A. de; Jong, Werner U. de; Takx, Richard A.P.; Eikendal, Anouk L.M.; Willemink, Martin J.; Mohamed Hoesein, Firdaus A.A.; Oudkerk, Matthijs; Budde, Ricardo P.J.

    2016-01-01

    To determine inter-observer and inter-examination variability of manual attenuation measurements of the vertebrae in low-dose unenhanced chest computed tomography (CT). Three hundred and sixty-seven lung cancer screening trial participants who underwent baseline and repeat unenhanced low-dose CT after 3 months because of an indeterminate lung nodule were included. The CT attenuation value of the first lumbar vertebrae (L1) was measured in all CTs by one observer to obtain inter-examination reliability. Six observers performed measurements in 100 randomly selected CTs to determine agreement with limits of agreement and Bland-Altman plots and reliability with intraclass correlation coefficients (ICCs). Reclassification analyses were performed using a threshold of 110 HU to define osteoporosis. Inter-examination reliability was excellent with an ICC of 0.92 (p < 0.001). Inter-examination limits of agreement ranged from -26 to 28 HU with a mean difference of 1 ± 14 HU. Inter-observer reliability ICCs ranged from 0.70 to 0.91. Inter-examination variability led to 11.2 % reclassification of participants and inter-observer variability led to 22.1 % reclassification. Vertebral attenuation values can be manually quantified with good to excellent inter-examination and inter-observer reliability on unenhanced low-dose chest CT. This information is valuable for early detection of osteoporosis on low-dose chest CT. (orig.)

  10. Technical Training seminar: Texas Instruments

    CERN Multimedia

    2006-01-01

    Monday 6 November TECHNICAL TRAINING SEMINAR 14:00 to 17:30 - Training Centre Auditorium (bldg. 593) Texas Instruments Technical Seminar Michael Scholtholt, Field Application Engineer / TEXAS INSTRUMENTS (US, D, CH) POWER - A short approach to Texas Instruments power products Voltage mode vs. current mode control Differentiating DC/DC converters by analyzing control and compensation schemes: line / load regulation, transient response, BOM, board space, ease-of-use Introduction to the SWIFT software FPGA + CPLD power solutions WIRELESS / CHIPCON Decision criteria when choosing a RF platform Introduction to Texas Instruments wireless products: standardized platforms proprietary platforms ( 2.4 GHz / sub 1 GHz) development tools Antenna design: example for 2.4 GHz questions, discussion Industrial partners: Robert Medioni, François Caloz / Spoerle Electronic, CH-1440 Montagny (VD), Switzerland Phone: +41 24 447 0137, email: RMedioni@spoerle.com, http://www.spoerle.com Language: English. Free s...

  11. Partitioning inter annual variability in net ecosystem exchange between climatic variability and functional change

    International Nuclear Information System (INIS)

    Hui, D.; Luo, Y.; Katul, G.

    2003-01-01

    Inter annual variability in net ecosystem exchange of carbon is investigated using a homogeneity-of-slopes model to identify the function change contributing to inter annual variability, net ecosystem carbon exchange, and night-time ecosystem respiration. Results of employing this statistical approach to a data set collected at the Duke Forest AmeriFlux site from August 1997 to December 2001 are discussed. The results demonstrate that it is feasible to partition the variation in ecosystem carbon fluxes into direct effects of seasonal and inter annual climatic variability and functional change. 51 refs., 4 tabs., 5 figs

  12. 76 FR 38608 - Sensors and Instrumentation Technical Advisory Committee;

    Science.gov (United States)

    2011-07-01

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... of export controls applicable to sensors and instrumentation equipment and technology. Agenda Public...

  13. Large-Scale Processes Associated with Inter-Decadal and Inter-Annual Early Spring Rainfall Variability in Taiwan

    Directory of Open Access Journals (Sweden)

    Jau-Ming Chen

    2016-02-01

    Full Text Available Early spring (March - April rainfall in Taiwan exhibits evident and distinct inter-annual and inter-decadal variability. The inter-annual varibility has a positive correlation with the El Niño/Southern Oscillation while the inter-decadal variability features a phase change beginning in the late 1970s, coherent with the major phase change in the Pacific decadal oscillation. Rainfall variability in both timescales is regulated by large-scale processes showing consistent dynamic features. Rainfall increases are associated with positive sea surface temperature (SST anomalies in the tropical eastern Pacific and negative SST anomalies in the tropical central Pacific. An anomalous lower-level divergent center appears in the tropical central Pacific. Via a Rossby-wave-like response, an anomalous lower-level anticyclone appears to the southeast of Taiwan over the Philippine Sea-tropical western Pacific region, which is accompanied by an anomalous cyclone to the north-northeast of Taiwan. Both circulation anomalies induce anomalous southwesterly flows to enhance moisture flux from the South China Sea onto Taiwan, resulting in significant moisture convergence nearby Taiwan. With enhanced moisture supplied by anomalous southwesterly flows, significant rainfall increases occur in both inter-annual and inter-decadal timescales in early spring rainfall on Taiwan.

  14. Validity evidence of non-technical skills assessment instruments in simulated anaesthesia crisis management.

    Science.gov (United States)

    Jirativanont, T; Raksamani, K; Aroonpruksakul, N; Apidechakul, P; Suraseranivongse, S

    2017-07-01

    We sought to evaluate the validity of two non-technical skills evaluation instruments, the Anaesthetists' Non-Technical Skills (ANTS) behavioural marker system and the Ottawa Global Rating Scale (GRS), to apply them to anaesthesia training. The content validity, response process, internal structure, relations with other variables and consequences were described for validity evidence. Simulated crisis management sessions were initiated during which two trained raters evaluated the performance of postgraduate first-, second- and third-year (PGY-1, PGY-2 and PGY-3) anaesthesia residents. The study included 70 participants, composed of 24 PGY-1, 24 PGY-2 and 22 PGY-3 residents. Both instruments differentiated the non-technical skills of PGY-1 from PGY-3 residents ( P skills were 0.86, 0.83, 0.84, 0.87, 0.80 and 0.86, respectively. The Cronbach's alpha for internal consistency of the ANTS instrument was 0.93, and was 0.96 for the Ottawa GRS. There was a high correlation between the ANTS and Ottawa GRS. The raters reported the ease of use of the Ottawa GRS compared to the ANTS. We found sufficient evidence of validity in the ANTS instrument and the Ottawa GRS for the evaluation of non-technical skills in a simulated anaesthesia setting, but the Ottawa GRS was more practical and had higher reliability.

  15. Customisation of an instrument to assess anaesthesiologists' non-technical skills.

    Science.gov (United States)

    Jepsen, Rikke M H G; Spanager, Lene; Lyk-Jensen, Helle T; Dieckmann, Peter; Østergaard, Doris

    2015-02-22

    The objectives of the study were to identify Danish anaesthesiologists' non-technical skills and to customise the Scottish-developed Anaesthetists' Non-Technical Skills instrument for Danish anaesthesiologists. Six semi-structured group interviews were conducted with 31 operating room team members: anaes-thesiologists, nurse anaesthetists, surgeons, and scrub nurses. Interviews were transcribed verbatim and analysed using directed content analysis. Anaesthesiologists' non-technical skills were identified, coded, and sorted using the original instrument as a basis. The resulting prototype instrument was discussed with anaesthesiologists from 17 centres to ensure face validity. Interviews lasted 46-67 minutes. Identified examples of anaesthesiologists' good or poor non-technical skills fit the four categories in the original instrument: situation awareness; decision making; team working; and task management. Anaesthesiologists' leadership role in the operating room was emphasised: the original 'Task Management' category was named 'Leadership'. One new element, 'Demonstrating self-awareness' was added under the category 'Situation Awareness'. Compared with the original instrument, half of the behavioural markers were new, which reflected that being aware of and communicating one's own abilities to the team; working systematically; and speaking up to avoid adverse events were important skills. The Anaesthetists' Non-Technical Skills instrument was customised to a Danish setting using the identified non-technical skills for anaesthesiologists and the original instrument as basis. The customised instrument comprises four categories and 16 underpinning elements supported by multiple behavioural markers. Identifying non-technical skills through semi-structured group interviews and analysing them using direct content analysis proved a useful method for customising an assessment instrument to another setting.

  16. Cardiac valve calcifications on low-dose unenhanced ungated chest computed tomography: inter-observer and inter-examination reliability, agreement and variability

    International Nuclear Information System (INIS)

    Hamersvelt, Robbert W. van; Willemink, Martin J.; Takx, Richard A.P.; Eikendal, Anouk L.M.; Budde, Ricardo P.J.; Leiner, Tim; Jong, Pim A. de; Mol, Christian P.; Isgum, Ivana

    2014-01-01

    To determine inter-observer and inter-examination variability for aortic valve calcification (AVC) and mitral valve and annulus calcification (MC) in low-dose unenhanced ungated lung cancer screening chest computed tomography (CT). We included 578 lung cancer screening trial participants who were examined by CT twice within 3 months to follow indeterminate pulmonary nodules. On these CTs, AVC and MC were measured in cubic millimetres. One hundred CTs were examined by five observers to determine the inter-observer variability. Reliability was assessed by kappa statistics (κ) and intra-class correlation coefficients (ICCs). Variability was expressed as the mean difference ± standard deviation (SD). Inter-examination reliability was excellent for AVC (κ = 0.94, ICC = 0.96) and MC (κ = 0.95, ICC = 0.90). Inter-examination variability was 12.7 ± 118.2 mm 3 for AVC and 31.5 ± 219.2 mm 3 for MC. Inter-observer reliability ranged from κ = 0.68 to κ = 0.92 for AVC and from κ = 0.20 to κ = 0.66 for MC. Inter-observer ICC was 0.94 for AVC and ranged from 0.56 to 0.97 for MC. Inter-observer variability ranged from -30.5 ± 252.0 mm 3 to 84.0 ± 240.5 mm 3 for AVC and from -95.2 ± 210.0 mm 3 to 303.7 ± 501.6 mm 3 for MC. AVC can be quantified with excellent reliability on ungated unenhanced low-dose chest CT, but manual detection of MC can be subject to substantial inter-observer variability. Lung cancer screening CT may be used for detection and quantification of cardiac valve calcifications. (orig.)

  17. Cardiac valve calcifications on low-dose unenhanced ungated chest computed tomography: inter-observer and inter-examination reliability, agreement and variability

    Energy Technology Data Exchange (ETDEWEB)

    Hamersvelt, Robbert W. van; Willemink, Martin J.; Takx, Richard A.P.; Eikendal, Anouk L.M.; Budde, Ricardo P.J.; Leiner, Tim; Jong, Pim A. de [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Mol, Christian P.; Isgum, Ivana [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands)

    2014-07-15

    To determine inter-observer and inter-examination variability for aortic valve calcification (AVC) and mitral valve and annulus calcification (MC) in low-dose unenhanced ungated lung cancer screening chest computed tomography (CT). We included 578 lung cancer screening trial participants who were examined by CT twice within 3 months to follow indeterminate pulmonary nodules. On these CTs, AVC and MC were measured in cubic millimetres. One hundred CTs were examined by five observers to determine the inter-observer variability. Reliability was assessed by kappa statistics (κ) and intra-class correlation coefficients (ICCs). Variability was expressed as the mean difference ± standard deviation (SD). Inter-examination reliability was excellent for AVC (κ = 0.94, ICC = 0.96) and MC (κ = 0.95, ICC = 0.90). Inter-examination variability was 12.7 ± 118.2 mm{sup 3} for AVC and 31.5 ± 219.2 mm{sup 3} for MC. Inter-observer reliability ranged from κ = 0.68 to κ = 0.92 for AVC and from κ = 0.20 to κ = 0.66 for MC. Inter-observer ICC was 0.94 for AVC and ranged from 0.56 to 0.97 for MC. Inter-observer variability ranged from -30.5 ± 252.0 mm{sup 3} to 84.0 ± 240.5 mm{sup 3} for AVC and from -95.2 ± 210.0 mm{sup 3} to 303.7 ± 501.6 mm{sup 3} for MC. AVC can be quantified with excellent reliability on ungated unenhanced low-dose chest CT, but manual detection of MC can be subject to substantial inter-observer variability. Lung cancer screening CT may be used for detection and quantification of cardiac valve calcifications. (orig.)

  18. Improving the Accuracy of Laplacian Estimation with Novel Variable Inter-Ring Distances Concentric Ring Electrodes

    Directory of Open Access Journals (Sweden)

    Oleksandr Makeyev

    2016-06-01

    Full Text Available Noninvasive concentric ring electrodes are a promising alternative to conventional disc electrodes. Currently, the superiority of tripolar concentric ring electrodes over disc electrodes, in particular, in accuracy of Laplacian estimation, has been demonstrated in a range of applications. In our recent work, we have shown that accuracy of Laplacian estimation can be improved with multipolar concentric ring electrodes using a general approach to estimation of the Laplacian for an (n + 1-polar electrode with n rings using the (4n + 1-point method for n ≥ 2. This paper takes the next step toward further improving the Laplacian estimate by proposing novel variable inter-ring distances concentric ring electrodes. Derived using a modified (4n + 1-point method, linearly increasing and decreasing inter-ring distances tripolar (n = 2 and quadripolar (n = 3 electrode configurations are compared to their constant inter-ring distances counterparts. Finite element method modeling and analytic results are consistent and suggest that increasing inter-ring distances electrode configurations may decrease the truncation error resulting in more accurate Laplacian estimates compared to respective constant inter-ring distances configurations. For currently used tripolar electrode configuration, the truncation error may be decreased more than two-fold, while for the quadripolar configuration more than a six-fold decrease is expected.

  19. Improving the Accuracy of Laplacian Estimation with Novel Variable Inter-Ring Distances Concentric Ring Electrodes

    Science.gov (United States)

    Makeyev, Oleksandr; Besio, Walter G.

    2016-01-01

    Noninvasive concentric ring electrodes are a promising alternative to conventional disc electrodes. Currently, the superiority of tripolar concentric ring electrodes over disc electrodes, in particular, in accuracy of Laplacian estimation, has been demonstrated in a range of applications. In our recent work, we have shown that accuracy of Laplacian estimation can be improved with multipolar concentric ring electrodes using a general approach to estimation of the Laplacian for an (n + 1)-polar electrode with n rings using the (4n + 1)-point method for n ≥ 2. This paper takes the next step toward further improving the Laplacian estimate by proposing novel variable inter-ring distances concentric ring electrodes. Derived using a modified (4n + 1)-point method, linearly increasing and decreasing inter-ring distances tripolar (n = 2) and quadripolar (n = 3) electrode configurations are compared to their constant inter-ring distances counterparts. Finite element method modeling and analytic results are consistent and suggest that increasing inter-ring distances electrode configurations may decrease the truncation error resulting in more accurate Laplacian estimates compared to respective constant inter-ring distances configurations. For currently used tripolar electrode configuration, the truncation error may be decreased more than two-fold, while for the quadripolar configuration more than a six-fold decrease is expected. PMID:27294933

  20. RNA-seq: technical variability and sampling

    Science.gov (United States)

    2011-01-01

    Background RNA-seq is revolutionizing the way we study transcriptomes. mRNA can be surveyed without prior knowledge of gene transcripts. Alternative splicing of transcript isoforms and the identification of previously unknown exons are being reported. Initial reports of differences in exon usage, and splicing between samples as well as quantitative differences among samples are beginning to surface. Biological variation has been reported to be larger than technical variation. In addition, technical variation has been reported to be in line with expectations due to random sampling. However, strategies for dealing with technical variation will differ depending on the magnitude. The size of technical variance, and the role of sampling are examined in this manuscript. Results In this study three independent Solexa/Illumina experiments containing technical replicates are analyzed. When coverage is low, large disagreements between technical replicates are apparent. Exon detection between technical replicates is highly variable when the coverage is less than 5 reads per nucleotide and estimates of gene expression are more likely to disagree when coverage is low. Although large disagreements in the estimates of expression are observed at all levels of coverage. Conclusions Technical variability is too high to ignore. Technical variability results in inconsistent detection of exons at low levels of coverage. Further, the estimate of the relative abundance of a transcript can substantially disagree, even when coverage levels are high. This may be due to the low sampling fraction and if so, it will persist as an issue needing to be addressed in experimental design even as the next wave of technology produces larger numbers of reads. We provide practical recommendations for dealing with the technical variability, without dramatic cost increases. PMID:21645359

  1. Creating a Super Instrument

    DEFF Research Database (Denmark)

    Kallionpää, Maria; Gasselseder, Hans-Peter

    2015-01-01

    Thanks to the development of new technology, musical instruments are no more tied to their existing acoustic or technical limitations as almost all parameters can be augmented or modified in real time. An increasing number of composers, performers, and computer programmers have thus become intere...

  2. Intraregional and inter-regional variability of herbicide sensitivity in common arable weed populations

    DEFF Research Database (Denmark)

    de Mol, Friederike; Gerowitt, Bärbel; Kaczmarek, Sylwia

    2015-01-01

    The question on intraregional versus inter-regional variability in herbicide sensitivity for weed populations is of major importance, both in extrapolation of model parameters and in herbicide zonal approval procedures. We hypothesised that inter-regional variability in herbicide sensitivity for ...

  3. Instrumental Variables in the Long Run

    DEFF Research Database (Denmark)

    Casey, Gregory; Klemp, Marc Patrick Brag

    2017-01-01

    In the study of long-run economic growth, it is common to use historical or geographical variables as instruments for contemporary endogenous regressors. We study the interpretation of these conventional instrumental variable (IV) regressions in a general, yet simple, framework. Our aim...... quantitative implications for the field of long-run economic growth. We also use our framework to examine related empirical techniques. We find that two prominent regression methodologies - using gravity-based instruments for trade and including ancestry-adjusted variables in linear regression models - have...... is to estimate the long-run causal effect of changes in the endogenous explanatory variable. We find that conventional IV regressions generally cannot recover this parameter of interest. To estimate this parameter, therefore, we develop an augmented IV estimator that combines the conventional regression...

  4. Quantitative label-free proteomics for discovery of biomarkers in cerebrospinal fluid: assessment of technical and inter-individual variation.

    Directory of Open Access Journals (Sweden)

    Richard J Perrin

    Full Text Available Biomarkers are required for pre-symptomatic diagnosis, treatment, and monitoring of neurodegenerative diseases such as Alzheimer's disease. Cerebrospinal fluid (CSF is a favored source because its proteome reflects the composition of the brain. Ideal biomarkers have low technical and inter-individual variability (subject variance among control subjects to minimize overlaps between clinical groups. This study evaluates a process of multi-affinity fractionation (MAF and quantitative label-free liquid chromatography tandem mass spectrometry (LC-MS/MS for CSF biomarker discovery by (1 identifying reparable sources of technical variability, (2 assessing subject variance and residual technical variability for numerous CSF proteins, and (3 testing its ability to segregate samples on the basis of desired biomarker characteristics.Fourteen aliquots of pooled CSF and two aliquots from six cognitively normal individuals were randomized, enriched for low-abundance proteins by MAF, digested endoproteolytically, randomized again, and analyzed by nano-LC-MS. Nano-LC-MS data were time and m/z aligned across samples for relative peptide quantification. Among 11,433 aligned charge groups, 1360 relatively abundant ones were annotated by MS2, yielding 823 unique peptides. Analyses, including Pearson correlations of annotated LC-MS ion chromatograms, performed for all pairwise sample comparisons, identified several sources of technical variability: i incomplete MAF and keratins; ii globally- or segmentally-decreased ion current in isolated LC-MS analyses; and iii oxidized methionine-containing peptides. Exclusion of these sources yielded 609 peptides representing 81 proteins. Most of these proteins showed very low coefficients of variation (CV<5% whether they were quantified from the mean of all or only the 2 most-abundant peptides. Unsupervised clustering, using only 24 proteins selected for high subject variance, yielded perfect segregation of pooled and

  5. Making the most of LCA in technical inter-organisational R&D projects

    DEFF Research Database (Denmark)

    Sandin, Gustav; Clancy, Gunilla; Heimersson, Sara

    2014-01-01

    In technical Research and Development (R&D) projects, a Life Cycle Assessment (LCA) of the technology under development is sometimes carried out. Particularly in inter-organisational R&D projects, the roles of LCAs tend to be unclear and arbitrary, and as a consequence, LCA work is not adequately...... designed for the needs of the project. There is a need for research on how to choose an appropriate role for LCA in such projects and how to plan LCA work accordingly. We have identified some possible roles of LCA in inter-organisational R&D projects and used experiences from LCA work in different...... such projects to identify four project characteristics that are decisive for what roles the LCA can have. The project characteristics are: (i) the project's potential influence on environmental impacts, (ii) the degrees of freedom available for the technical direction of the project, (iii) the project...

  6. Texas Instruments Technical Seminar: Power Management and Wireless

    CERN Multimedia

    2006-01-01

    Monday 6 November TECHNICAL TRAINING SEMINAR 14:00 to 17:30 - Training Centre Auditorium (bldg. 593) Texas Instruments Technical Seminar: Power Management and Wireless Michael Scholtholt, Field Application Engineer / TEXAS INSTRUMENTS (US, D, CH) The range of power management products available today offers the possibility to find the best solution for each application. To select the right product it is therefore necessary to understand system requirements, how power supply products work, and where they differentiate. This Technical Training Seminar will also present an overview of how to choose the right RF platform based on markets and applications: nowadays almost everbody has at least one wireless product in use, and this tendency seems to increase significantly. Power Management Voltage mode vs. current mode control Differentiating DC/DC converters by analyzing control and compensation schemes: line / load regulation, transient response, BOM, board space, ease-of-use Introduction to evaluati...

  7. Texas Instruments Technical Seminar: Power Management and Wireless

    CERN Multimedia

    2006-01-01

    Monday 6 November TECHNICAL TRAINING SEMINAR 14:00 to 17:30 - Training Centre Auditorium (bldg. 593) Texas Instruments Technical Seminar: Power Management and Wireless Michael Scholtholt, Field Application Engineer / TEXAS INSTRUMENTS (US, D, CH) The range of power management products available today offers the possibility to find the best solution for each application. To select the right product it is therefore necessary to understand system requirements, how power supply products work, and where they differentiate. This Technical Training Seminar will also present an overview of how to choose the right RF platform based on markets and applications: nowadays almost everbody has at least one wireless product in use, and this tendency seems to increase significantly. Power Management Voltage mode vs. current mode control Differentiating DC/DC converters by analyzing control and compensation schemes: line / load regulation, transient response, BOM, board space, ease-of-use Introduction to evalu...

  8. Inter-operator Variability in Defining Uterine Position Using Three-dimensional Ultrasound Imaging

    DEFF Research Database (Denmark)

    Baker, Mariwan; Jensen, Jørgen Arendt; Behrens, Claus F.

    2013-01-01

    significantly larger inter-fractional uterine positional displacement, in some cases up to 20 mm, which outweighs the magnitude of current inter-operator variations. Thus, the current US-phantom-study suggests that the inter-operator variability in addressing uterine position is clinically irrelevant.......In radiotherapy the treatment outcome of gynecological (GYN) cancer patients is crucially related to reproducibility of the actual uterine position. The purpose of this study is to evaluate the inter-operator variability in addressing uterine position using a novel 3-D ultrasound (US) system....... The study is initiated by US-scanning of a uterine phantom (CIRS 404, Universal Medical, Norwood, USA) by seven experienced US operators. The phantom represents a female pelvic region, containing a uterus, bladder and rectal landmarks readily definable in the acquired US-scans. The organs are subjected...

  9. Inter-Trial Gait Variability Reduction Using Continous Curve Registration

    National Research Council Canada - National Science Library

    Sadeghi, H

    2001-01-01

    Timing in peak gait values shifts slightly between gait trials. When gait data are averaged, some of the standard deviation can be associated to this inter-trial variability unless normalization is carried out beforehand...

  10. Interaction of Socio-Demographic Background Variables with Inter ...

    African Journals Online (AJOL)

    Interaction of Socio-Demographic Background Variables with Inter-Spousal Communication Among Married Couples in Alimosho Local Government Area of Lagos State, Nigeria. ... marriage will increase from 20-24years to 25-29years due to the number of years of couple's educational pursuit in Lagos state of Nigeria.

  11. Instrumental variable methods in comparative safety and effectiveness research.

    Science.gov (United States)

    Brookhart, M Alan; Rassen, Jeremy A; Schneeweiss, Sebastian

    2010-06-01

    Instrumental variable (IV) methods have been proposed as a potential approach to the common problem of uncontrolled confounding in comparative studies of medical interventions, but IV methods are unfamiliar to many researchers. The goal of this article is to provide a non-technical, practical introduction to IV methods for comparative safety and effectiveness research. We outline the principles and basic assumptions necessary for valid IV estimation, discuss how to interpret the results of an IV study, provide a review of instruments that have been used in comparative effectiveness research, and suggest some minimal reporting standards for an IV analysis. Finally, we offer our perspective of the role of IV estimation vis-à-vis more traditional approaches based on statistical modeling of the exposure or outcome. We anticipate that IV methods will be often underpowered for drug safety studies of very rare outcomes, but may be potentially useful in studies of intended effects where uncontrolled confounding may be substantial.

  12. Instrumental variable methods in comparative safety and effectiveness research†

    Science.gov (United States)

    Brookhart, M. Alan; Rassen, Jeremy A.; Schneeweiss, Sebastian

    2010-01-01

    Summary Instrumental variable (IV) methods have been proposed as a potential approach to the common problem of uncontrolled confounding in comparative studies of medical interventions, but IV methods are unfamiliar to many researchers. The goal of this article is to provide a non-technical, practical introduction to IV methods for comparative safety and effectiveness research. We outline the principles and basic assumptions necessary for valid IV estimation, discuss how to interpret the results of an IV study, provide a review of instruments that have been used in comparative effectiveness research, and suggest some minimal reporting standards for an IV analysis. Finally, we offer our perspective of the role of IV estimation vis-à-vis more traditional approaches based on statistical modeling of the exposure or outcome. We anticipate that IV methods will be often underpowered for drug safety studies of very rare outcomes, but may be potentially useful in studies of intended effects where uncontrolled confounding may be substantial. PMID:20354968

  13. A review of instrumental variable estimators for Mendelian randomization.

    Science.gov (United States)

    Burgess, Stephen; Small, Dylan S; Thompson, Simon G

    2017-10-01

    Instrumental variable analysis is an approach for obtaining causal inferences on the effect of an exposure (risk factor) on an outcome from observational data. It has gained in popularity over the past decade with the use of genetic variants as instrumental variables, known as Mendelian randomization. An instrumental variable is associated with the exposure, but not associated with any confounder of the exposure-outcome association, nor is there any causal pathway from the instrumental variable to the outcome other than via the exposure. Under the assumption that a single instrumental variable or a set of instrumental variables for the exposure is available, the causal effect of the exposure on the outcome can be estimated. There are several methods available for instrumental variable estimation; we consider the ratio method, two-stage methods, likelihood-based methods, and semi-parametric methods. Techniques for obtaining statistical inferences and confidence intervals are presented. The statistical properties of estimates from these methods are compared, and practical advice is given about choosing a suitable analysis method. In particular, bias and coverage properties of estimators are considered, especially with weak instruments. Settings particularly relevant to Mendelian randomization are prioritized in the paper, notably the scenario of a continuous exposure and a continuous or binary outcome.

  14. 77 FR 61737 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2012-10-11

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... level of export controls applicable to sensors and instrumentation equipment and technology. Agenda...

  15. 77 FR 37652 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2012-06-22

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... of export controls applicable to sensors and instrumentation equipment and technology. Agenda Public...

  16. 75 FR 1339 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2010-01-11

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... level of export controls applicable to sensors and instrumentation equipment and technology. Agenda...

  17. 77 FR 2270 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2012-01-17

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... the level of export controls applicable to sensors and instrumentation equipment and technology...

  18. 78 FR 1198 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2013-01-08

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... level of export controls applicable to sensors and instrumentation equipment and technology. Agenda...

  19. 76 FR 323 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2011-01-04

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... level of export controls applicable to sensors and instrumentation equipment and technology. Agenda...

  20. 75 FR 39920 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2010-07-13

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... of export controls applicable to sensors and instrumentation equipment and technology. Agenda Public...

  1. 78 FR 19638 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2013-04-02

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... level of export controls applicable to sensors and instrumentation equipment and technology. Agenda...

  2. 76 FR 63607 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2011-10-13

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... level of export controls applicable to sensors and instrumentation equipment and technology. Agenda...

  3. 78 FR 60251 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2013-10-01

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... level of export controls applicable to sensors and instrumentation equipment and technology. [[Page...

  4. 78 FR 40098 - Sensors And Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2013-07-03

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors And Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... of export controls applicable to sensors and instrumentation equipment and technology. Agenda Public...

  5. 77 FR 23222 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2012-04-18

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... of export controls applicable to sensors and instrumentation equipment and technology. Agenda Public...

  6. 75 FR 14426 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2010-03-25

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... of export controls applicable to sensors and instrumentation equipment and technology. Agenda Public...

  7. 75 FR 62508 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2010-10-12

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... level of export controls applicable to sensors and instrumentation equipment and technology. Agenda...

  8. TECHNICAL TRAINING SEMINAR: National Instruments

    CERN Multimedia

    Monique Duval

    2004-01-01

    From 9:30 to 12:00 and from 13:00 to 16:00 hrs - Council Chamber, Salle B, Salle des Pas Perdus National Instruments (NI) on Tour 2004 Claudia Jüngel, Evrem Yarkin, Joel Clerc, Hervé Baour / NATIONAL INSTRUMENTS The special event NI on Tour 2004, run in Germany, Austria and Switzerland, will be at CERN on March 30. Technical seminars and free introductory courses will be offered all day long in the Council Chamber, Salle B, and Salle des Pas Perdus (buildings 61 and 503). Data acquisition systems on PCs, industrial measurement and control techniques, advanced LabVIEW software and PXI instrumentation, and system components for tests and automation will be presented. Walk-in courses will address DIAdem, LabVIEW and data acquisition. Language: English and French Free seminars and courses, no registration Organisers: Rolf Stampfli / IT-CO / 78102 & 160367 / Rolf.Stampfli@cern.ch Davide Vitè / HR-PMD-ATT / 75141 Davide.Vite@cern.ch For more information and the complete event programme, please visit the...

  9. Power calculator for instrumental variable analysis in pharmacoepidemiology.

    Science.gov (United States)

    Walker, Venexia M; Davies, Neil M; Windmeijer, Frank; Burgess, Stephen; Martin, Richard M

    2017-10-01

    Instrumental variable analysis, for example with physicians' prescribing preferences as an instrument for medications issued in primary care, is an increasingly popular method in the field of pharmacoepidemiology. Existing power calculators for studies using instrumental variable analysis, such as Mendelian randomization power calculators, do not allow for the structure of research questions in this field. This is because the analysis in pharmacoepidemiology will typically have stronger instruments and detect larger causal effects than in other fields. Consequently, there is a need for dedicated power calculators for pharmacoepidemiological research. The formula for calculating the power of a study using instrumental variable analysis in the context of pharmacoepidemiology is derived before being validated by a simulation study. The formula is applicable for studies using a single binary instrument to analyse the causal effect of a binary exposure on a continuous outcome. An online calculator, as well as packages in both R and Stata, are provided for the implementation of the formula by others. The statistical power of instrumental variable analysis in pharmacoepidemiological studies to detect a clinically meaningful treatment effect is an important consideration. Research questions in this field have distinct structures that must be accounted for when calculating power. The formula presented differs from existing instrumental variable power formulae due to its parametrization, which is designed specifically for ease of use by pharmacoepidemiologists. © The Author 2017. Published by Oxford University Press on behalf of the International Epidemiological Association

  10. Quality control procedures applied to nuclear instruments. Proceedings of a technical meeting

    International Nuclear Information System (INIS)

    2008-11-01

    Quality Control (QC), test procedures for Nuclear Instrumentation are important for assurance of proper and safe operation of the instruments, especially with regard to equipment related to radiological safety, human health and national safety. Correct measurements of radiation parameters must be ensured, i.e., accurate measurement of the number of radioactive events, counting times and in some cases accurate measurements of the radiation energy and occurring time of the nuclear events. There are several kinds of testing on nuclear instruments, for example, type-testing done by suppliers, acceptance testing made by the end users, Quality Control tests after repair and Quality Assurance/Quality Controls tests made by end-users. All of these tests are based in many cases on practical guidelines or on the experience of the own specialist, the available standards on this topic also need to be adapted to specific instruments. The IAEA has provided nuclear instruments and supported the operational maintenance efforts of the Member States. Although Nuclear Instrumentation is continuously upgraded, some older or aged instruments are still in use and in good working condition. Some of these instruments may not, however, meet modern requirements for the end-user therefore, Member States, mostly those with emerging economies, modernize/refurbish such instruments to meet the end-user demands. As a result, new instrumentation which is not commercially available, or modernized/refurbished instruments, need to be tested or verified with QC procedures to meet national or international certification requirements. A technical meeting on QC procedures applied to nuclear instruments was organized in Vienna from 23 to 24 August 2007. Existing and required QC test procedures necessary for the verification of operation and measurement of the main characteristics of nuclear instruments was the focus of discussion at this meeting. Presentations made at the technical meeting provided

  11. IASI instrument: technical description and measured performances

    Science.gov (United States)

    Hébert, Ph.; Blumstein, D.; Buil, C.; Carlier, T.; Chalon, G.; Astruc, P.; Clauss, A.; Siméoni, D.; Tournier, B.

    2017-11-01

    IASI is an infrared atmospheric sounder. It will provide meteorologist and scientific community with atmospheric spectra. The IASI system includes 3 instruments that will be mounted on the Metop satellite series, a data processing software integrated in the EPS (EUMETSAT Polar System) ground segment and a technical expertise centre implemented in CNES Toulouse. The instrument is composed of a Fourier transform spectrometer and an associated infrared imager. The optical configuration is based on a Michelson interferometer and the interferograms are processed by an on-board digital processing subsystem, which performs the inverse Fourier transforms and the radiometric calibration. The infrared imager co-registers the IASI soundings with AVHRR imager (AVHRR is another instrument on the Metop satellite). The presentation will focus on the architectures of the instrument, the description of the implemented technologies and the measured performance of the first flight model. CNES is leading the IASI program in association with EUMETSAT. The instrument Prime is ALCATEL SPACE.

  12. Does using the interRAI Palliative Care instrument reduce the needs and symptoms of nursing home residents receiving palliative care?

    Science.gov (United States)

    Hermans, Kirsten; De Almeida Mello, Johanna; Spruytte, Nele; Cohen, Joachim; Van Audenhove, Chantal; Declercq, Anja

    2018-02-01

    This study aimed to evaluate whether using the interRAI Palliative Care instrument (the interRAI PC) in nursing homes is associated with reduced needs and symptoms in residents nearing the end of their lives. A quasi-experimental pretest-posttest study using the Palliative care Outcome Scale (POS) was conducted to compare the needs and symptoms of residents nearing the end of their lives in the control and intervention nursing homes. Care professionals at the intervention nursing homes filled out the interRAI PC over the course of a year for all residents aged 65 years and older who were nearing the end of their lives. This intervention was not implemented in the control nursing homes. At baseline, POS scores in the intervention nursing homes were lower (more favorable) than in the control nursing homes on the items "pain", "other symptoms", "family anxiety", and the total POS score. Posttest POS scores for "wasted time" were higher (less favorable) than pretest scores in the intervention nursing homes. In the intervention nursing homes where care professionals did not have prior experience with the interRAI Long-Term Care Facilities (LTCF) assessment instrument (n = 8/15), total POS scores were lower (more favorable) at posttest. One year after introducing the interRAI PC, no reduction in residents' needs and symptoms were detected in the intervention nursing homes. However, reductions in needs and symptoms were found in the subgroup of intervention nursing homes without prior experience with the interRAI LTCF instrument. This may suggest that the use of an interRAI instrument other than the interRAI PC specifically can improve care. Future research should aim at replicating this research with a long-term design in order to evaluate the effect of integrating the use of the interRAI PC in the day-to-day practices at nursing homes.

  13. The predicted CLARREO sampling error of the inter-annual SW variability

    Science.gov (United States)

    Doelling, D. R.; Keyes, D. F.; Nguyen, C.; Macdonnell, D.; Young, D. F.

    2009-12-01

    The NRC Decadal Survey has called for SI traceability of long-term hyper-spectral flux measurements in order to monitor climate variability. This mission is called the Climate Absolute Radiance and Refractivity Observatory (CLARREO) and is currently defining its mission requirements. The requirements are focused on the ability to measure decadal change of key climate variables at very high accuracy. The accuracy goals are set using anticipated climate change magnitudes, but the accuracy achieved for any given climate variable must take into account the temporal and spatial sampling errors based on satellite orbits and calibration accuracy. The time period to detect a significant trend in the CLARREO record depends on the magnitude of the sampling calibration errors relative to the current inter-annual variability. The largest uncertainty in climate feedbacks remains the effect of changing clouds on planetary energy balance. Some regions on earth have strong diurnal cycles, such as maritime stratus and afternoon land convection; other regions have strong seasonal cycles, such as the monsoon. However, when monitoring inter-annual variability these cycles are only important if the strength of these cycles vary on decadal time scales. This study will attempt to determine the best satellite constellations to reduce sampling error and to compare the error with the current inter-annual variability signal to ensure the viability of the mission. The study will incorporate Clouds and the Earth's Radiant Energy System (CERES) (Monthly TOA/Surface Averages) SRBAVG product TOA LW and SW climate quality fluxes. The fluxes are derived by combining Terra (10:30 local equator crossing time) CERES fluxes with 3-hourly 5-geostationary satellite estimated broadband fluxes, which are normalized using the CERES fluxes, to complete the diurnal cycle. These fluxes were saved hourly during processing and considered the truth dataset. 90°, 83° and 74° inclination precessionary orbits as

  14. Inter-individual Differences in Heart Rate Variability Are Associated with Inter-individual Differences in Empathy and Alexithymia

    Directory of Open Access Journals (Sweden)

    Alexander Lischke

    2018-02-01

    Full Text Available In the present study, we investigated whether inter-individual differences in vagally mediated heart rate variability (vmHRV would be associated with inter-individual differences in empathy and alexithymia. To this end, we determined resting state HF-HRV in 90 individuals that also completed questionnaires assessing inter-individual differences in empathy and alexithymia. Our categorical and dimensional analyses revealed that inter-individual differences in HF-HRV were differently associated with inter-individual differences in empathy and alexithymia. We found that individuals with high HF-HRV reported more empathy and less alexithymia than individuals with low HF-HRV. Moreover, we even found that an increase in HF-HRV was associated with an increase in empathy and a decrease in alexithymia across all participants. Taken together, these findings indicate that individuals with high HF-HRV are more empathetic and less alexithymic than individuals with low HF-HRV. These differences in empathy and alexithymia may explain why individuals with high HF-HRV are more successful in sharing and understanding the mental and emotional states of others than individuals with low HF-HRV.

  15. Eliminating Survivor Bias in Two-stage Instrumental Variable Estimators.

    Science.gov (United States)

    Vansteelandt, Stijn; Walter, Stefan; Tchetgen Tchetgen, Eric

    2018-07-01

    Mendelian randomization studies commonly focus on elderly populations. This makes the instrumental variables analysis of such studies sensitive to survivor bias, a type of selection bias. A particular concern is that the instrumental variable conditions, even when valid for the source population, may be violated for the selective population of individuals who survive the onset of the study. This is potentially very damaging because Mendelian randomization studies are known to be sensitive to bias due to even minor violations of the instrumental variable conditions. Interestingly, the instrumental variable conditions continue to hold within certain risk sets of individuals who are still alive at a given age when the instrument and unmeasured confounders exert additive effects on the exposure, and moreover, the exposure and unmeasured confounders exert additive effects on the hazard of death. In this article, we will exploit this property to derive a two-stage instrumental variable estimator for the effect of exposure on mortality, which is insulated against the above described selection bias under these additivity assumptions.

  16. 76 FR 20948 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2011-04-14

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... of export controls applicable to sensors [[Page 20949

  17. Instrument and Survey Analysis Technical Report: Program Implementation Survey. Technical Report #1112

    Science.gov (United States)

    Alonzo, Julie; Tindal, Gerald

    2011-01-01

    This technical document provides guidance to educators on the creation and interpretation of survey instruments, particularly as they relate to an analysis of program implementation. Illustrative examples are drawn from a survey of educators related to the use of the easyCBM learning system. This document includes specific sections on…

  18. Longitudinal intra- and inter-individual variability in young swimmers' performance and determinant competition factors

    Directory of Open Access Journals (Sweden)

    Jorge Estrela Morais

    2014-09-01

    Full Text Available The main purpose of this study was to follow-up the intra- and inter-individual variability of young swimmers' performance and determinant factors over two competitive seasons. Thirty young swimmers (14 boys: 12.33±0.65 years-old; 16 girls: 11.15±0.55 years-old were followed-up throughout two consecutive seasons (seven evaluation moments. Performance (100m freestyle, anthropometric, kinematic, hydrodynamic and efficiency features were evaluated. A gender and skill-level effect was observed. Boys improved in a higher amount (% comparing to girls. Overall, swimmers in skill-level 2 (both genders presented a higher intra-individual variability. Performance and anthropometrics showed a significant inter-individual variability in most moments, but hydrodynamics, kinematics and efficiency did not. Within each skill-level hydrodynamics, kinematics and efficiency were the variables that showed a high inter-individual variability. As a gender and skill-level effect was noticed in an age-group of young swimmers, coaches and practitioners should put the focus in specific and customized training plans for each skill-level of swimmers.

  19. Falsification Testing of Instrumental Variables Methods for Comparative Effectiveness Research.

    Science.gov (United States)

    Pizer, Steven D

    2016-04-01

    To demonstrate how falsification tests can be used to evaluate instrumental variables methods applicable to a wide variety of comparative effectiveness research questions. Brief conceptual review of instrumental variables and falsification testing principles and techniques accompanied by an empirical application. Sample STATA code related to the empirical application is provided in the Appendix. Comparative long-term risks of sulfonylureas and thiazolidinediones for management of type 2 diabetes. Outcomes include mortality and hospitalization for an ambulatory care-sensitive condition. Prescribing pattern variations are used as instrumental variables. Falsification testing is an easily computed and powerful way to evaluate the validity of the key assumption underlying instrumental variables analysis. If falsification tests are used, instrumental variables techniques can help answer a multitude of important clinical questions. © Health Research and Educational Trust.

  20. Inter-individual cognitive variability in children with Asperger’s syndrome

    Directory of Open Access Journals (Sweden)

    Maria Luz Gonzalez-Gadea

    2014-07-01

    Full Text Available Multiple studies have tried to establish the distinctive profile of individuals with Asperger’s syndrome (AS. However, recent reports suggest that adults with AS feature heterogeneous cognitive profiles. The present study explores inter-individual variability in children with AS through group comparison and multiple case series analysis. All participants completed an extended battery including measures of fluid and crystallized intelligence, executive functions, theory of mind, and classical neuropsychological tests. Significant group differences were found in theory of mind and other domains related to global information processing. However, the AS group showed high inter-individual variability (both sub- and supra-normal performance on most cognitive tasks. Furthermore, high fluid intelligence correlated with less general cognitive impairment, high cognitive flexibility, and speed motor processing. In light of these findings, we propose that children with AS are characterized by a distinct, uneven pattern of cognitive strengths and weaknesses.

  1. Characterization of inter-tissue and inter-strain variability of TCE glutathione conjugation metabolites DCVG, DCVC, and NAcDCVC in the mouse.

    Science.gov (United States)

    Luo, Yu-Syuan; Furuya, Shinji; Chiu, Weihsueh; Rusyn, Ivan

    2018-01-01

    Trichloroethylene (TCE) is a ubiquitous environmental toxicant that is a liver and kidney carcinogen. Conjugation of TCE with glutathione (GSH) leads to formation of nepthrotoxic and mutagenic metabolites postulated to be critical for kidney cancerdevelopment; however, relatively little is known regarding their tissue levels as previous analytical methods for their detection lacked sensitivity. Here, an LC-MS/MS-based method for simultaneous detection of S-(1,2-dichlorovinyl)-glutathione (DCVG), S-(1,2-dichlorovinyl)-L-cysteine (DCVC), and N-acetyl-S-(1,2-dichlorovinyl)-L-cysteine (NAcDCVC) in multiple mouse tissues was developed. This analytical method is rapid, sensitive (limits of detection (LOD) 3-30 fmol across metabolites and tissues), and robust to quantify all three metabolites in liver, kidneys, and serum. The method was used to characterize inter-tissue and inter-strain variability in formation of conjugative metabolites of TCE. Single oral dose of TCE (24, 240 or 800 mg/kg) was administered to male mice from 20 inbred strains of Collaborative Cross. Inter-strain variability in the levels of DCVG, DCVC, and NAcDCVC (GSD = 1.6-2.9) was observed. Whereas NAcDCVC was distributed equally among analyzed tissues, highest levels of DCVG were detected in liver and DCVC in kidneys. Evidence indicated that inter-strain variability in conjugative metabolite formation of TCE might affect susceptibility to adverse health effects and that this method might aid in filling data gaps in human health assessment of TCE.

  2. Design and validation of an observational instrument for technical and tactical actions in beach volleyball

    Directory of Open Access Journals (Sweden)

    José Manuel Palao

    2015-06-01

    Full Text Available Technical and tactical actions determine performance in beach volleyball. This research develops and tests an instrument to monitor and evaluate the manner of execution and efficacy of the actions in beach volleyball. The purpose of this paper was to design and validate an observational instrument to analyze technical and tactical actions in beach volleyball. The instrument collects information regarding: a information about the match (context, b information about game situations, c information about technical situations (serve, reception, set, attack, block, and court defense in relation to player execution, role, manner of execution, execution zone, and efficacy, and d information about the result of the play (win-lose and way point is obtained. Instrument design and validation was done in seven stages: a review of literature and consultation of experts; b pilot observation and data analysis; c expert review of instrument (qualitative and quantitative evaluation; d observer training test; e expert review of instrument (content validity; f measurement of the ability of the instrument to discriminate the result of the set; and g measurement of the ability of the instrument to differentiate between competition age groups. The results show that the instrument allows for obtaining objective and valid information about the players and team from offensive and defensive technical and tactical actions, as well as indirectly from physical actions. The instrument can be used, in its entirety or partially, for researching and coaching purposes.

  3. Inter-subject variability in human atrial action potential in sinus rhythm versus chronic atrial fibrillation.

    Directory of Open Access Journals (Sweden)

    Carlos Sánchez

    Full Text Available Human atrial electrophysiology exhibits high inter-subject variability in both sinus rhythm (SR and chronic atrial fibrillation (cAF patients. Variability is however rarely investigated in experimental and theoretical electrophysiological studies, thus hampering the understanding of its underlying causes but also its implications in explaining differences in the response to disease and treatment. In our study, we aim at investigating the ability of populations of human atrial cell models to capture the inter-subject variability in action potential (AP recorded in 363 patients both under SR and cAF conditions.Human AP recordings in atrial trabeculae (n = 469 from SR and cAF patients were used to calibrate populations of computational SR and cAF atrial AP models. Three populations of over 2000 sampled models were generated, based on three different human atrial AP models. Experimental calibration selected populations of AP models yielding AP with morphology and duration in range with experimental recordings. Populations using the three original models can mimic variability in experimental AP in both SR and cAF, with median conductance values in SR for most ionic currents deviating less than 30% from their original peak values. All cAF populations show similar variations in G(K1, G(Kur and G(to, consistent with AF-related remodeling as reported in experiments. In all SR and cAF model populations, inter-subject variability in I(K1 and I(NaK underlies variability in APD90, variability in I(Kur, I(CaL and I(NaK modulates variability in APD50 and combined variability in Ito and I(Kur determines variability in APD20. The large variability in human atrial AP triangulation is mostly determined by I(K1 and either I(NaK or I(NaCa depending on the model.Experimentally-calibrated human atrial AP models populations mimic AP variability in SR and cAF patient recordings, and identify potential ionic determinants of inter-subject variability in human atrial AP

  4. Validation procedures of software applied in nuclear instruments. Proceedings of a technical meeting

    International Nuclear Information System (INIS)

    2007-09-01

    The IAEA has supported the availability of well functioning nuclear instruments in Member States over more than three decades. Some older or aged instruments are still being used and are still in good working condition. However, those instruments may not meet modern software requirements for the end-user in all cases. Therefore, Member States, mostly those with emerging economies, modernize/refurbish such instruments to meet the end-user demands. New advanced software is not only applied in case of new instrumentation, but often also for new and improved applications of modernized and/or refurbished instruments in many Member States for which in few cases the IAEA also provided support. Modern software applied in nuclear instrumentation plays a key role for their safe operation and execution of commands in a user friendly manner. Correct data handling and transfer has to be ensured. Additional features such as data visualization, interfacing to PC for control and data storage are often included. To finalize the task, where new instrumentation which is not commercially available is used, or aged instruments are modernized/refurbished, the applied software has to be verified and validated. A Technical Meeting on 'Validation Procedures of Software Applied in Nuclear Instruments' was organized in Vienna, 20-23 November 2006, to discuss the verification and validation process of software applied to operation and use of nuclear instruments. The presentations at the technical meeting included valuable information, which has been compiled and summarized in this publication, which should be useful for technical staff in Member States when modernizing/refurbishing nuclear instruments. 22 experts in the field of modernization/refurbishment of nuclear instruments as well as users of applied software presented their latest results. Discussion sessions followed the presentations. This publication is the outcome of deliberations during the meeting

  5. Inter-laboratory project q calibration of SANS instruments using silver behenate

    International Nuclear Information System (INIS)

    Ikram, Abarrul; Gunawan; Edy Giri, Putra; Suzuki, Jun-ichi; Knott, Robert

    2000-01-01

    The inter-laboratory project for q-calibration of SANS (small angle neutron scattering) using silver behenate was carried out among Indonesia National Nuclear Energy Agency (BATAN), Japan Atomic Energy Research Institute (JAERI) and Australian Nuclear Science and Technology Organization (ANSTO). The standard sample of silver behenate, [CH 3 (CH 2 ) 20 COOAg](AgBE), has been assessed as an international standard for the calibration of both x-ray and neutron scattering instruments. The results indicate excellent agreement for q calibration obtained among the three laboratories, BATAN, JAERI and ANSTO. (Y. Kazumata)

  6. Governance and control as mediating instruments in an inter-firm relationship : Towards collaboration or transactions?

    NARCIS (Netherlands)

    Zahir-Ul-Hassan, Muhammad Kaleem; Minnaar, Reinald A.; Vosselman, E.G.J.

    2016-01-01

    This paper explores the mediation of governance and control structures in an inter-firm relationship between a semiconductor producer and its contractor. As mediating instruments the contract and the control structures are not just pre-given results of distanced managerial decision-making, but are

  7. Governance and control as mediating instruments in an inter-firm relationship: towards collaboration or transactions?

    NARCIS (Netherlands)

    Zahir-ul-Hassan, M.K.; Minnaar, R.A.; Vosselman, E.G.J.

    2016-01-01

    This paper explores the mediation of governance and control structures in an inter-firm relationship between a semiconductor producer and its contractor. As mediating instruments the contract and the control structures are not just pre-given results of distanced managerial decision-making, but are

  8. Instrumental variables I: instrumental variables exploit natural variation in nonexperimental data to estimate causal relationships.

    Science.gov (United States)

    Rassen, Jeremy A; Brookhart, M Alan; Glynn, Robert J; Mittleman, Murray A; Schneeweiss, Sebastian

    2009-12-01

    The gold standard of study design for treatment evaluation is widely acknowledged to be the randomized controlled trial (RCT). Trials allow for the estimation of causal effect by randomly assigning participants either to an intervention or comparison group; through the assumption of "exchangeability" between groups, comparing the outcomes will yield an estimate of causal effect. In the many cases where RCTs are impractical or unethical, instrumental variable (IV) analysis offers a nonexperimental alternative based on many of the same principles. IV analysis relies on finding a naturally varying phenomenon, related to treatment but not to outcome except through the effect of treatment itself, and then using this phenomenon as a proxy for the confounded treatment variable. This article demonstrates how IV analysis arises from an analogous but potentially impossible RCT design, and outlines the assumptions necessary for valid estimation. It gives examples of instruments used in clinical epidemiology and concludes with an outline on estimation of effects.

  9. Inter-observer variability between radiologists reporting on cerebellopontine angle tumours on magnetic resonance imaging.

    Science.gov (United States)

    Teh, S R; Ranguis, S; Fagan, P

    2017-01-01

    Studies demonstrate the significance of intra- and inter-observer variability when measuring cerebellopontine angle tumours on magnetic resonance imaging, with measured differences as high as 2 mm. To determine intra- and inter-observer measurement variability of cerebellopontine angle tumours in a specialised institution. The magnetic resonance imaging maximal diameter of 12 randomly selected cerebellopontine angle tumours were independently measured by 4 neuroradiologists at a tertiary referral centre using a standard definition for maximal tumour diameter. Average deviation and intraclass correlation were subsequently calculated. Inter-observer difference averaged 0.33 ± 0.04 mm (range, 0.0-0.8 mm). Intra-observer measurements were more consistent than inter-observer measurements, with differences averaging 0.17 mm (95 per cent confidence interval = 0.27-0.06, p = 0.002). Inter-observer reliability was 0.99 (95 per cent confidence interval = 0.97-0.99), suggesting high reliability between the readings. The use of a standard definition for maximal tumour volume provided high reliability amongst radiologists' readings. To avoid oversizing tumours, it is recommended that conservative monitoring be conducted by the same institution with thin slice magnetic resonance imaging scans.

  10. Nuclear instrument maintenance and technical training in Nuclear Energy Unit

    International Nuclear Information System (INIS)

    Mohamad Nasir Abdul Wahid

    1987-01-01

    Instrument maintenance service is a necessity in a Nuclear Research Institute, such as the Nuclear Energy Unit (NEU) to ensure the smooth running of our research activities. However, realising that maintenance back-up service for either nuclear or other scientific equipment is a major problem in developing countries such as Malaysia, NEU has set up an Instrumentation and Control Department to assist in rectifying the maintenance problem. Beside supporting in house activities in NEU, the Instrumentation and Control Department (I and C) is also geared into providing services to other organisations in Malaysia. This paper will briefly outline the activities of NEU in nuclear instrument maintenance as well as in technical training. (author)

  11. High inter-specimen variability of baseline data for the tibio-talar contact area.

    Science.gov (United States)

    Matricali, Giovanni A; Bartels, Ward; Labey, Luc; Dereymaeker, Greta Ph E; Luyten, Frank P; Vander Sloten, Jos

    2009-01-01

    The tibio-talar contact area has been widely investigated to monitor biomechanical changes due to articular incongruities or an altered loading. This study aims to investigate for the first time in a systematic way the extent of the inter-specimen variability of the tibio-talar contact area, and its repercussions when analyzing data concerning this parameter. Ten specimens were loaded to record the tibio-talar contact characteristics by use of pressure sensitive film. The size of the talar dome area, the size of the (normalized) tibio-talar contact area, the position of the tibio-talar contact area, and the shape of the latter were determined and analyzed. Inter-specimen variability was expressed as the coefficient of variation and was calculated for the datasets of previous studies as well. The size of the tibio-talar contact area showed a very high inter-specimen variability, as is the case in previous studies. This high variability persisted when a normalized tibio-talar contact area was calculated. The shape of the tibio-talar contact area showed some basic characteristics, but a high variation in details could be observed. Every specimen can be considered to have its own "ankle print". By this variability, articular incongruities are expected to have a different effect on local biomechanical characteristics in every single individual. Therefore, every single case has to be evaluated and reported for significant changes. In case of modeling, this also underscores the need to use subject specific models fed by sets of parameters derived from a series of single specimens.

  12. Calcium scoring with prospectively ECG-triggered CT: Using overlapping datasets generated with MPR decreases inter-scan variability

    International Nuclear Information System (INIS)

    Rutten, A.; Isgum, I.; Prokop, M.

    2011-01-01

    Objective: To examine the feasibility of reducing the inter-scan variability of prospectively ECG-triggered calcium-scoring scans by using overlapping 3-mm datasets generated from multiplanar reformation (MPR) instead of non-overlapping 3-mm or 1.5-mm datasets. Patients and methods: Seventy-five women (59-79 years old) underwent two sequential prospectively ECG-triggered calcium-scoring scans with 16 mm x 1.5 mm collimation in one session. Between the two scans patients got off and on the table. We performed calcium scoring (Agatston and mass scores) on the following datasets: contiguous 3-mm sections reconstructed from the raw data (A), contiguous 3-mm sections from MPR (B), overlapping 3-mm sections from MPR (C) and contiguous 1.5-mm sections from the raw data (D). To determine the feasibility of the MPR approach, we compared MPR (B) with direct raw data reconstruction (A). Inter-scan variability was calculated for each type of dataset (A-D). Results: Calcium scores ranged from 0 to 1455 (Agatston) and 0 to 279 mg (mass) for overlapping 3-mm sections (C). Calcium scores (both Agatston and mass) were nearly identical for MPR (B) and raw data approaches (A), with inter-quartile ranges of 0-1% for inter-scan variability. Median inter-scan variability with contiguous 3-mm sections (B) was 13% (Agatston) and 11% (mass). Median variability was reduced to 10% (Agatston and mass) with contiguous 1.5-mm sections (D) and to 8% (Agatston) and 7% (mass) with overlapping 3-mm MPR (A). Conclusion: Calcium scoring on MPR yields nearly identical results to calcium scoring on images directly reconstructed from raw data. Overlapping MPR from prospectively ECG-triggered scans improve inter-scan variability of calcium scoring without increasing patient radiation dose.

  13. 78 FR 63161 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting...

    Science.gov (United States)

    2013-10-23

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting ``Rescheduled'' The Sensors and Instrumentation... that affect the level of export controls applicable to sensors and instrumentation equipment and...

  14. Inter-Subject Variability of Axonal Injury in Diffuse Traumatic Brain Injury.

    Science.gov (United States)

    Ware, Jeffrey B; Hart, Tessa; Whyte, John; Rabinowitz, Amanda; Detre, John A; Kim, Junghoon

    2017-07-15

    Traumatic brain injury (TBI) is a leading cause of cognitive morbidity worldwide for which reliable biomarkers are needed. Diffusion tensor imaging (DTI) is a promising biomarker of traumatic axonal injury (TAI); however, existing studies have been limited by a primary reliance on group-level analytic methods not well suited to account for inter-subject variability. In this study, 42 adults with TBI of at least moderate severity were examined 3 months following injury and compared with 35 healthy controls. DTI data were used for both traditional group-level comparison and subject-specific analysis using the distribution-corrected Z-score (DisCo-Z) approach. Inter-subject variation in TAI was assessed in a threshold-invariant manner using a threshold-weighted overlap map derived from subject-specific analysis. Receiver operator curve analysis was used to examine the ability of subject-specific DTI analysis to identify TBI subjects with significantly impaired processing speed in comparison with region of interest-based fractional anisotropy (FA) measurements and clinical characteristics. Traditional group-wise analysis demonstrated widespread reductions of white matter FA within the TBI group (voxel-wise p traumatic deficits in processing speed. Significant group-level effects do not necessarily represent consistent effects at the individual level. Better accounting for inter-subject variability in neurobiological manifestations of TBI may substantially improve the ability to detect and classify patterns of injury.

  15. Inter-observer variability in fetal biometric measurements.

    Science.gov (United States)

    Kilani, Rami; Aleyadeh, Wesam; Atieleh, Luay Abu; Al Suleimat, Abdul Mane; Khadra, Maysa; Hawamdeh, Hassan M

    2018-02-01

    To evaluate inter-observer variability and reproducibility of ultrasound measurements for fetal biometric parameters. A prospective cohort study was implemented in two tertiary care hospitals in Amman, Jordan; Prince Hamza Hospital and Albashir Hospital. 192 women with a singleton pregnancy at a gestational age of 18-36 weeks were the participants in the study. Transabdominal scans for fetal biometric parameter measurement were performed on study participants from the period of November 2014 to March 2015. Women who agreed to participate in the study were administered two ultrasound scans for head circumference, abdominal circumference and femur length. The correlation coefficient was calculated. Bland-Altman plots were used to analyze the degree of measurement agreement between observers. Limits of agreement ± 2 SD for the differences in fetal biometry measurements in proportions of the mean of the measurements were derived. Main outcome measures examine the reproducibility of fetal biometric measurements by different observers. High inter-observer inter-class correlation coefficient (ICC) was found for femur length (0.990) and abdominal circumference (0.996) where Bland-Altman plots showed high degrees of agreement. The highest degrees of agreement were noted in the measurement of abdominal circumference followed by head circumference. The lowest degree of agreement was found for femur length measurement. We used a paired-sample t-test and found that the mean difference between duplicate measurements was not significant (P > 0.05). Biometric fetal parameter measurements may be reproducible by different operators in the clinical setting with similar results. Fetal head circumference, abdominal circumference and femur length were highly reproducible. Large organized studies are needed to ensure accurate fetal measurements due to the important clinical implications of inaccurate measurements. Copyright © 2018. Published by Elsevier B.V.

  16. Inter-annual variability of North Sea plaice spawning habitat

    Science.gov (United States)

    Loots, C.; Vaz, S.; Koubbi, P.; Planque, B.; Coppin, F.; Verin, Y.

    2010-11-01

    Potential spawning habitat is defined as the area where environmental conditions are suitable for spawning to occur. Spawning adult data from the first quarter (January-March) of the International Bottom Trawl Survey have been used to study the inter-annual variability of the potential spawning habitat of North Sea plaice from 1980 to 2007. Generalised additive models (GAM) were used to create a model that related five environmental variables (depth, bottom temperature and salinity, seabed stress and sediment type) to presence-absence and abundance of spawning adults. Then, the habitat model was applied each year from 1970 to 2007 to predict inter-annual variability of the potential spawning habitat. Predicted responses obtained by GAM for each year were mapped using kriging. A hierarchical classification associated with a correspondence analysis was performed to cluster spawning suitable areas and to determine how they evolved across years. The potential spawning habitat was consistent with historical spawning ground locations described in the literature from eggs surveys. It was also found that the potential spawning habitat varied across years. Suitable areas were located in the southern part of the North Sea and along the eastern coast of England and Scotland in the eighties; they expanded further north from the nineties. Annual survey distributions did not show such northward expansion and remained located in the southern North Sea. This suggests that this species' actual spatial distribution remains stable against changing environmental conditions, and that the potential spawning habitat is not fully occupied. Changes in environmental conditions appear to remain within plaice environmental ranges, meaning that other factors may control the spatial distribution of plaice spawning habitat.

  17. On the Interpretation of Instrumental Variables in the Presence of Specification Errors

    Directory of Open Access Journals (Sweden)

    P.A.V.B. Swamy

    2015-01-01

    Full Text Available The method of instrumental variables (IV and the generalized method of moments (GMM, and their applications to the estimation of errors-in-variables and simultaneous equations models in econometrics, require data on a sufficient number of instrumental variables that are both exogenous and relevant. We argue that, in general, such instruments (weak or strong cannot exist.

  18. Definition of gross tumor volume in lung cancer: inter-observer variability

    International Nuclear Information System (INIS)

    Van de Steene, Jan; Linthout, Nadine; Mey, Johan de; Vinh-Hung, Vincent; Claassens, Cornelia; Noppen, Marc; Bel, Arjan; Storme, Guy

    2002-01-01

    Background and purpose: To determine the inter-observer variation in gross tumor volume (GTV) definition in lung cancer, and its clinical relevance. Material and methods: Five clinicians involved in lung cancer were asked to define GTV on the planning CT scan of eight patients. Resulting GTVs were compared on the base of geometric volume, dimensions and extensions. Judgement of invasion of lymph node (LN) regions was evaluated using the ATS/LCSG classification of LN. Clinical relevance of the variation was studied through 3D-dosimetry of standard conformal plans: volume of critical organs (heart, lungs, esophagus, spinal cord) irradiated at toxic doses, 95% isodose volumes of GTVs, normal tissue complication probabilities (NTCP) and tumor control probabilities (TCP) were compared for evaluation of observer variability. Results: Before evaluation of observer variability, critical review of planning CT scan led to up- (two cases) and downstaging (one case) of patients as compared to the respective diagnostic scans. The defined GTVs showed an inter-observer variation with a ratio up to more than 7 between maximum and minimum geometric content. The dimensions of the primary tumor had inter-observer ranges of 4.2 (transversal), 7.9 (cranio-caudal) and 5.4 (antero-posterior) cm. Extreme extensions of the GTVs (left, right, cranial, caudal, anterior and posterior) varied with ranges of 2.8-7.3 cm due to inter-observer variation. After common review, only 63% of involved lymph node regions were delineated by the clinicians (i.e. 37% are false negative). Twenty-two percent of drawn in lymph node regions were accepted to be false positive after review. In the conformal plans, inter-observer ranges of irradiated normal tissue volume were on average 12%, with a maximum of 66%. The probability (in the population of all conformal plans) of irradiating at least 95% of the GTV with at least 95% of the nominal treatment dose decreased from 96 to 88% when swapping the matched GTV

  19. A multi-segment foot model based on anatomically registered technical coordinate systems: method repeatability in pediatric feet.

    Science.gov (United States)

    Saraswat, Prabhav; MacWilliams, Bruce A; Davis, Roy B

    2012-04-01

    Several multi-segment foot models to measure the motion of intrinsic joints of the foot have been reported. Use of these models in clinical decision making is limited due to lack of rigorous validation including inter-clinician, and inter-lab variability measures. A model with thoroughly quantified variability may significantly improve the confidence in the results of such foot models. This study proposes a new clinical foot model with the underlying strategy of using separate anatomic and technical marker configurations and coordinate systems. Anatomical landmark and coordinate system identification is determined during a static subject calibration. Technical markers are located at optimal sites for dynamic motion tracking. The model is comprised of the tibia and three foot segments (hindfoot, forefoot and hallux) and inter-segmental joint angles are computed in three planes. Data collection was carried out on pediatric subjects at two sites (Site 1: n=10 subjects by two clinicians and Site 2: five subjects by one clinician). A plaster mold method was used to quantify static intra-clinician and inter-clinician marker placement variability by allowing direct comparisons of marker data between sessions for each subject. Intra-clinician and inter-clinician joint angle variability were less than 4°. For dynamic walking kinematics, intra-clinician, inter-clinician and inter-laboratory variability were less than 6° for the ankle and forefoot, but slightly higher for the hallux. Inter-trial variability accounted for 2-4° of the total dynamic variability. Results indicate the proposed foot model reduces the effects of marker placement variability on computed foot kinematics during walking compared to similar measures in previous models. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. 77 FR 66178 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting...

    Science.gov (United States)

    2012-11-02

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting; Rescheduled The Sensors and Instrumentation... that affect the level of export controls applicable to sensors [[Page 66179

  1. Outcome indicators for the evaluation of energy policy instruments and technical change

    International Nuclear Information System (INIS)

    Neij, Lena; Astrand, Kerstin

    2006-01-01

    The aim of this paper is to propose a framework for the evaluation of policy instruments designed to affect development and dissemination of new energy technologies. The evaluation approach is based on the analysis of selected outcome indicators describing the process of technical change, i.e. the development and dissemination of new energy technologies, on the basis of a socio-technical systems approach. The outcome indicators are used to analyse the effect, in terms of outcome, and outcome scope of the policy instruments as well as the extent to which the policy instruments support diversity, learning and institutional change. The analysis of two cases of evaluations, of energy efficiency policy and wind energy policy in Sweden, shows that the approach has several advantages, allowing continuous evaluation and providing important information for the redesign of policy instruments. There are also disadvantages associated with the approach, such as complexity, possible high cost and the requirement of qualified evaluators. Nevertheless, it is concluded that the information on the continuous performance of different policy instruments and their effects on the introduction and dissemination of new energy technologies, provided by this evaluation approach, is essential for an improved adaptation and implementation of energy and climate policy

  2. Approaches for modeling within subject variability in pharmacometric count data analysis: dynamic inter-occasion variability and stochastic differential equations.

    Science.gov (United States)

    Deng, Chenhui; Plan, Elodie L; Karlsson, Mats O

    2016-06-01

    Parameter variation in pharmacometric analysis studies can be characterized as within subject parameter variability (WSV) in pharmacometric models. WSV has previously been successfully modeled using inter-occasion variability (IOV), but also stochastic differential equations (SDEs). In this study, two approaches, dynamic inter-occasion variability (dIOV) and adapted stochastic differential equations, were proposed to investigate WSV in pharmacometric count data analysis. These approaches were applied to published count models for seizure counts and Likert pain scores. Both approaches improved the model fits significantly. In addition, stochastic simulation and estimation were used to explore further the capability of the two approaches to diagnose and improve models where existing WSV is not recognized. The results of simulations confirmed the gain in introducing WSV as dIOV and SDEs when parameters vary randomly over time. Further, the approaches were also informative as diagnostics of model misspecification, when parameters changed systematically over time but this was not recognized in the structural model. The proposed approaches in this study offer strategies to characterize WSV and are not restricted to count data.

  3. The Effects of Inter-annual Climate Variability on the Departures of Leatherback Marine Turtles from the California Current Ecosystem

    OpenAIRE

    Van Zerr, Vanessa E

    2013-01-01

    The Pacific Ocean is a highly variable environment, and changes in oceanographic conditions impact the distributions of many organisms. Inter-annual climate variability, especially the El Niño/Southern Oscillation, is known to have wide-ranging impacts on organisms in the California Current. Understanding the factors that drive changes in the spatial ecology of organisms, such as inter-annual climate variability, is essential in many cases for effective conservation. Leatherback marine turtle...

  4. SU-E-J-266: Cone Beam Computed Tomography (CBCT) Inter-Scan and Inter-Observer Tumor Volume Variability Assessment in Patients Treated with Stereotactic Body Radiation Therapy (SBRT) for Early Stage Non-Small Cell Lung Cancer (NSCLC)

    Energy Technology Data Exchange (ETDEWEB)

    Hou, Y; Aileen, C; Kozono, D; Killoran, J; Wagar, M; Lee, S; Hacker, F; Aerts, H; Lewis, J; Mak, R [Brigham and Women’s Hospital, Boston, MA (United States)

    2015-06-15

    Purpose: Quantification of volume changes on CBCT during SBRT for NSCLC may provide a useful radiological marker for radiation response and adaptive treatment planning, but the reproducibility of CBCT volume delineation is a concern. This study is to quantify inter-scan/inter-observer variability in tumor volume delineation on CBCT. Methods: Twenty earlystage (stage I and II) NSCLC patients were included in this analysis. All patients were treated with SBRT with a median dose of 54 Gy in 3 to 5 fractions. Two physicians independently manually contoured the primary gross tumor volume on CBCTs taken immediately before SBRT treatment (Pre) and after the same SBRT treatment (Post). Absolute volume differences (AVD) were calculated between the Pre and Post CBCTs for a given treatment to quantify inter-scan variability, and then between the two observers for a given CBCT to quantify inter-observer variability. AVD was also normalized with respect to average volume to obtain relative volume differences (RVD). Bland-Altman approach was used to evaluate variability. All statistics were calculated with SAS version 9.4. Results: The 95% limit of agreement (mean ± 2SD) on AVD and RVD measurements between Pre and Post scans were −0.32cc to 0.32cc and −0.5% to 0.5% versus −1.9 cc to 1.8 cc and −15.9% to 15.3% for the two observers respectively. The 95% limit of agreement of AVD and RVD between the two observers were −3.3 cc to 2.3 cc and −42.4% to 28.2% respectively. The greatest variability in inter-scan RVD was observed with very small tumors (< 5 cc). Conclusion: Inter-scan variability in RVD is greatest with small tumors. Inter-observer variability was larger than inter-scan variability. The 95% limit of agreement for inter-observer and inter-scan variability (∼15–30%) helps define a threshold for clinically meaningful change in tumor volume to assess SBRT response, with larger thresholds needed for very small tumors. Part of the work was funded by a Kaye

  5. SU-E-J-266: Cone Beam Computed Tomography (CBCT) Inter-Scan and Inter-Observer Tumor Volume Variability Assessment in Patients Treated with Stereotactic Body Radiation Therapy (SBRT) for Early Stage Non-Small Cell Lung Cancer (NSCLC)

    International Nuclear Information System (INIS)

    Hou, Y; Aileen, C; Kozono, D; Killoran, J; Wagar, M; Lee, S; Hacker, F; Aerts, H; Lewis, J; Mak, R

    2015-01-01

    Purpose: Quantification of volume changes on CBCT during SBRT for NSCLC may provide a useful radiological marker for radiation response and adaptive treatment planning, but the reproducibility of CBCT volume delineation is a concern. This study is to quantify inter-scan/inter-observer variability in tumor volume delineation on CBCT. Methods: Twenty earlystage (stage I and II) NSCLC patients were included in this analysis. All patients were treated with SBRT with a median dose of 54 Gy in 3 to 5 fractions. Two physicians independently manually contoured the primary gross tumor volume on CBCTs taken immediately before SBRT treatment (Pre) and after the same SBRT treatment (Post). Absolute volume differences (AVD) were calculated between the Pre and Post CBCTs for a given treatment to quantify inter-scan variability, and then between the two observers for a given CBCT to quantify inter-observer variability. AVD was also normalized with respect to average volume to obtain relative volume differences (RVD). Bland-Altman approach was used to evaluate variability. All statistics were calculated with SAS version 9.4. Results: The 95% limit of agreement (mean ± 2SD) on AVD and RVD measurements between Pre and Post scans were −0.32cc to 0.32cc and −0.5% to 0.5% versus −1.9 cc to 1.8 cc and −15.9% to 15.3% for the two observers respectively. The 95% limit of agreement of AVD and RVD between the two observers were −3.3 cc to 2.3 cc and −42.4% to 28.2% respectively. The greatest variability in inter-scan RVD was observed with very small tumors (< 5 cc). Conclusion: Inter-scan variability in RVD is greatest with small tumors. Inter-observer variability was larger than inter-scan variability. The 95% limit of agreement for inter-observer and inter-scan variability (∼15–30%) helps define a threshold for clinically meaningful change in tumor volume to assess SBRT response, with larger thresholds needed for very small tumors. Part of the work was funded by a Kaye

  6. Inter-annual and spatial variability in hillslope runoff and mercury flux during spring snowmelt.

    Science.gov (United States)

    Haynes, Kristine M; Mitchell, Carl P J

    2012-08-01

    Spring snowmelt is an important period of mercury (Hg) export from watersheds. Limited research has investigated the potential effects of climate variability on hydrologic and Hg fluxes during spring snowmelt. The purpose of this research was to assess the potential impacts of inter-annual climate variability on Hg mobility in forested uplands, as well as spatial variability in hillslope hydrology and Hg fluxes. We compared hydrological flows, Hg and solute mobility from three adjacent hillslopes in the S7 watershed of the Marcell Experimental Forest, Minnesota during two very different spring snowmelt periods: one following a winter (2009-2010) with severely diminished snow accumulation (snow water equivalent (SWE) = 48 mm) with an early melt, and a second (2010-2011) with significantly greater winter snow accumulation (SWE = 98 mm) with average to late melt timing. Observed inter-annual differences in total Hg (THg) and dissolved organic carbon (DOC) yields were predominantly flow-driven, as the proportion by which solute yields increased was the same as the increase in runoff. Accounting for inter-annual differences in flow, there was no significant difference in THg and DOC export between the two snowmelt periods. The spring 2010 snowmelt highlighted the important contribution of melting soil frost in the timing of a considerable portion of THg exported from the hillslope, accounting for nearly 30% of the THg mobilized. Differences in slope morphology and soil depths to the confining till layer were important in controlling the large observed spatial variability in hydrological flowpaths, transmissivity feedback responses, and Hg flux trends across the adjacent hillslopes.

  7. Development from childhood to adulthood increases morphological and functional inter-individual variability in the right superior temporal cortex.

    Science.gov (United States)

    Bonte, Milene; Frost, Martin A; Rutten, Sanne; Ley, Anke; Formisano, Elia; Goebel, Rainer

    2013-12-01

    We study the developmental trajectory of morphology and function of the superior temporal cortex (STC) in children (8-9 years), adolescents (14-15 years) and young adults. We analyze cortical surface landmarks and functional MRI (fMRI) responses to voices, other natural categories and tones and examine how hemispheric asymmetry and inter-subject variability change across age. Our results show stable morphological asymmetries across age groups, including a larger left planum temporale and a deeper right superior temporal sulcus. fMRI analyses show that a rightward lateralization for voice-selective responses is present in all groups but decreases with age. Furthermore, STC responses to voices change from being less selective and more spatially diffuse in children to highly selective and focal in adults. Interestingly, the analysis of morphological landmarks reveals that inter-subject variability increases during development in the right--but not in the left--STC. Similarly, inter-subject variability of cortically-realigned functional responses to voices, other categories and tones increases with age in the right STC. Our findings reveal asymmetric developmental changes in brain regions crucial for auditory and voice perception. The age-related increase of inter-subject variability in right STC suggests that anatomy and function of this region are shaped by unique individual developmental experiences. © 2013.

  8. Three-dimensional Mass Measurement of Subsolid Pulmonary Nodules on Chest CT: Intra and Inter-observer Variability

    Directory of Open Access Journals (Sweden)

    Huiting LIU

    2015-05-01

    Full Text Available Background and objective Subsolid pulmonary nodules tend to exhibit considerably slower growth rates than solid lesions, nevertheless, higher malignancy probability. The diagnosis of indeterminate nodules largely depends on the growth evaluation during follow-up. The growth can manifested as an increase in size or the appearance and/or subsequent increase of solid components. The mass reflect the product of volume and density and can be more sensitive in growth evaluation. However, the repeatability needs a further validation. The purpose of this study is to assess the intra and inter-observer variability of mass measurement for subsolid nodules. Methods 80 subsolid nodules in 44 patients were retrospectively enrolled. Both the volume and mass were measured by two radiologists using blind method independently. Intra-observer and inter-observer variability were analyzed and compared by Bland-Altman method intra-class correlation test and Wilcoxon test. Results Software achieved satisfied segmentation for 92.5% nodules. Of them, 35% underwent manual modification. The 95% limits of agreement for intra-observer variability were -11.5%-10.4% for mass and -8.4%-8.8% for volume. The 95% limits of agreement for inter-observer variability were -17.4%-19.3% for mass and -17.9%-19.4% for volume.The intra-class correlation foefficients between volume and mass measument was 0.95 and 0.93 (both P<0.001 and no significant differences (P=0.78, 0.09 was found for intra- and inter-observer variability. Manual modification of the segmentation caused the worse mass measurement repeatability in spite of the reader satisfaction. Conclusion The repeatability of mass measurement has no significant difference with that of volume measurement and may act as a reliable method in the follow-up of subsolid nodules.

  9. Breast cancer MRI radiomics: An overview of algorithmic features and impact of inter-reader variability in annotating tumors.

    Science.gov (United States)

    Saha, Ashirbani; Harowicz, Michael R; Mazurowski, Maciej A

    2018-04-16

    To review features used in MRI radiomics of breast cancer and study the inter-reader stability of the features METHODS: We implemented 529 algorithmic features that can be extracted from tumor and fibroglandular tissue (FGT) in breast MRIs. The features were identified based on a review of the existing literature with consideration of their usage, prognostic ability, and uniqueness. The set was then extended so that it comprehensively describes breast cancer imaging characteristics. The features were classified into 10 groups based on the type of data used to extract them and the type of calculation being performed. For the assessment of inter-reader variability, 4 fellowship-trained readers annotated tumors on pre-operative dynamic contrast enhanced MRIs for 50 breast cancer patients. Based on the annotations, an algorithm automatically segmented the image and extracted all features resulting in one set of features for each reader. For a given feature, the inter-reader stability was defined as the intra-class correlation coefficient (ICC) computed using the feature values obtained through all readers for all cases. The average inter-reader stability for all features was 0.8474 (95% CI: 0.8068-0.8858). The mean inter-reader stability was lower for tumor-based features (0.6348, 95% CI: 0.5391-0.7257) than FGT-based features (0.9984, 95% CI: 0.9970-0.9992). The feature group with the highest inter-reader stability quantifies breast and FGT volume. The feature group with the lowest inter-reader stability quantifies variations in tumor enhancement. Breast MRI radiomics features widely vary in terms of their stability in the presence of inter-reader variability. Appropriate measures need to be taken for reducing this variability in tumor-based radiomics. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  10. Endotracheal temperature and humidity measurements in laryngectomized patients: intra- and inter-patient variability

    NARCIS (Netherlands)

    Scheenstra, R.J.; Muller, S.H.; Vincent, A.; Sinaasappel, M.; Zuur, J.K.; Hilgers, F.J.M.

    2009-01-01

    This study assesses intra- and inter-patient variability in endotracheal climate (temperature and humidity) and effects of heat and moister exchangers (HME) in 16 laryngectomized individuals, measured repeatedly (N = 47). Inhalation Breath Length (IBL) was 1.35 s without HME and 1.05 s with HME (P <

  11. Endotracheal temperature and humidity measurements in laryngectomized patients: intra- and inter-patient variability

    NARCIS (Netherlands)

    Scheenstra, R. J.; Muller, S. H.; Vincent, A.; Sinaasappel, M.; Zuur, J. K.; Hilgers, Frans J. M.

    2009-01-01

    This study assesses intra- and inter-patient variability in endotracheal climate (temperature and humidity) and effects of heat and moister exchangers (HME) in 16 laryngectomized individuals, measured repeatedly (N = 47). Inhalation Breath Length (IBL) was 1.35 s without HME and 1.05 s with HME (P

  12. 78 FR 17871 - Changes To Implement the Technical Corrections to the Leahy-Smith America Invents Act as to Inter...

    Science.gov (United States)

    2013-03-25

    ... Business Method Patents--Definition of Technological Invention, 77 FR 48734 (Aug. 14, 2012) (final rule... Inter Partes Review AGENCY: United States Patent and Trademark Office, Commerce. ACTION: Final rule..., United States Code (``AIA Technical Corrections Act''). Consistent with the statutory changes, this final...

  13. Effects of Climatic Factors and Ecosystem Responses on the Inter-Annual Variability of Evapotranspiration in a Coniferous Plantation in Subtropical China

    Science.gov (United States)

    Xu, Mingjie; Wen, Xuefa; Wang, Huimin; Zhang, Wenjiang; Dai, Xiaoqin; Song, Jie; Wang, Yidong; Fu, Xiaoli; Liu, Yunfen; Sun, Xiaomin; Yu, Guirui

    2014-01-01

    Because evapotranspiration (ET) is the second largest component of the water cycle and a critical process in terrestrial ecosystems, understanding the inter-annual variability of ET is important in the context of global climate change. Eight years of continuous eddy covariance measurements (2003–2010) in a subtropical coniferous plantation were used to investigate the impacts of climatic factors and ecosystem responses on the inter-annual variability of ET. The mean and standard deviation of annual ET for 2003–2010 were 786.9 and 103.4 mm (with a coefficient of variation of 13.1%), respectively. The inter-annual variability of ET was largely created in three periods: March, May–June, and October, which are the transition periods between seasons. A set of look-up table approaches were used to separate the sources of inter-annual variability of ET. The annual ETs were calculated by assuming that (a) both the climate and ecosystem responses among years are variable (Vcli-eco), (b) the climate is variable but the ecosystem responses are constant (Vcli), and (c) the climate is constant but ecosystem responses are variable (Veco). The ETs that were calculated under the above assumptions suggested that the inter-annual variability of ET was dominated by ecosystem responses and that there was a negative interaction between the effects of climate and ecosystem responses. These results suggested that for long-term predictions of water and energy balance in global climate change projections, the ecosystem responses must be taken into account to better constrain the uncertainties associated with estimation. PMID:24465610

  14. Inter- and intra-population genetic variability of introduced silkworm (Bombyx mori L. strains raised in Bulgaria

    Directory of Open Access Journals (Sweden)

    Teodora Staykova

    2013-01-01

    Full Text Available The genetic variability of four populations belonging to two introduced silkworm strains (Bombyx mori L. of various origins has been studied using isoenzymic analysis of six enzyme systems. Nonspecific esterases, phosphoglucomutase, malate dehydrogenase, acid phosphatase, alkaline phosphatase and hexokinase from different tissue of larvae 5th instar have been analysed using PAGE. Polymorphism in six from a total of nine loci has been found. Inter- and intra-population differences have been ascertained expressed in different allele composition of the gene pool and different frequencies of alleles. A higher degree of inter-population variability has been reported on the acid phosphatase and a lower one – on the phosphoglucomutase.

  15. Patterns and controls of inter-annual variability in the terrestrial carbon budget

    Science.gov (United States)

    Marcolla, Barbara; Rödenbeck, Christian; Cescatti, Alessandro

    2017-08-01

    The terrestrial carbon fluxes show the largest variability among the components of the global carbon cycle and drive most of the temporal variations in the growth rate of atmospheric CO2. Understanding the environmental controls and trends of the terrestrial carbon budget is therefore essential to predict the future trajectories of the CO2 airborne fraction and atmospheric concentrations. In the present work, patterns and controls of the inter-annual variability (IAV) of carbon net ecosystem exchange (NEE) have been analysed using three different data streams: ecosystem-level observations from the FLUXNET database (La Thuile and 2015 releases), the MPI-MTE (model tree ensemble) bottom-up product resulting from the global upscaling of site-level fluxes, and the Jena CarboScope Inversion, a top-down estimate of surface fluxes obtained from observed CO2 concentrations and an atmospheric transport model. Consistencies and discrepancies in the temporal and spatial patterns and in the climatic and physiological controls of IAV were investigated between the three data sources. Results show that the global average of IAV at FLUXNET sites, quantified as the standard deviation of annual NEE, peaks in arid ecosystems and amounts to ˜ 120 gC m-2 y-1, almost 6 times more than the values calculated from the two global products (15 and 20 gC m-2 y-1 for MPI-MTE and the Jena Inversion, respectively). Most of the temporal variability observed in the last three decades of the MPI-MTE and Jena Inversion products is due to yearly anomalies, whereas the temporal trends explain only about 15 and 20 % of the variability, respectively. Both at the site level and on a global scale, the IAV of NEE is driven by the gross primary productivity and in particular by the cumulative carbon flux during the months when land acts as a sink. Altogether these results offer a broad view on the magnitude, spatial patterns and environmental drivers of IAV from a variety of data sources that can be

  16. Econometrics in outcomes research: the use of instrumental variables.

    Science.gov (United States)

    Newhouse, J P; McClellan, M

    1998-01-01

    We describe an econometric technique, instrumental variables, that can be useful in estimating the effectiveness of clinical treatments in situations when a controlled trial has not or cannot be done. This technique relies upon the existence of one or more variables that induce substantial variation in the treatment variable but have no direct effect on the outcome variable of interest. We illustrate the use of the technique with an application to aggressive treatment of acute myocardial infarction in the elderly.

  17. Optimal Inference for Instrumental Variables Regression with non-Gaussian Errors

    DEFF Research Database (Denmark)

    Cattaneo, Matias D.; Crump, Richard K.; Jansson, Michael

    This paper is concerned with inference on the coefficient on the endogenous regressor in a linear instrumental variables model with a single endogenous regressor, nonrandom exogenous regressors and instruments, and i.i.d. errors whose distribution is unknown. It is shown that under mild smoothness...

  18. Inter- and intra-strain variability of tandem repeats in Mycoplasma pneumoniae based on next-generation sequencing data.

    Science.gov (United States)

    Zhang, Jing; Song, Xiaohong; Ma, Marella J; Xiao, Li; Kenri, Tsuyoshi; Sun, Hongmei; Ptacek, Travis; Li, Shaoli; Waites, Ken B; Atkinson, T Prescott; Shibayama, Keigo; Dybvig, Kevin; Feng, Yanmei

    2017-02-01

    To characterize inter- and intra-strain variability of variable-number tandem repeats (VNTRs) in Mycoplasma pneumoniae to determine the optimal multilocus VNTR analysis scheme for improved strain typing. Whole genome assemblies and next-generation sequencing data from diverse M. pneumoniae isolates were used to characterize VNTRs and their variability, and to compare the strain discriminability of new VNTR and existing markers. We identified 13 VNTRs including five reported previously. These VNTRs displayed different levels of inter- and intra-strain copy number variations. All new markers showed similar or higher discriminability compared with existing VNTR markers and the P1 typing system. Our study provides novel insights into VNTR variations and potential new multilocus VNTR analysis schemes for improved genotyping of M. pneumoniae.

  19. Endodontic inter-appointment flare-ups: An example of chaos?

    Directory of Open Access Journals (Sweden)

    Poorya Jalali

    2015-01-01

    Full Text Available Introduction: Pain and/or swelling after instrumentation of a root canal constitute a significant complication during endodontic treatment. Despite a large number of articles discussing the causative factors behind endodontic flare-ups, the exact mechanism is still not understood. The Hypothesis: The seemingly irrational behavior of endodontic inter-appointment flare-ups may be due to sensitive dependence on initial conditions. A model based on Lorenz′ chaos theory is presented as a possible explanation for the sudden emergence and unpredictability of flare-ups. Evaluation of the Hypothesis: All studies agree on some common traits regarding inter-appointment flare-ups: Careful instrumentation can still cause flare-up; the host inflammatory response behaves as a complex nonlinear network; and also the poly-etiologic nature of this phenomenon all illustrate the sensitive dependence on initial conditions of the system. Integrating more variables (e.g., different species of bacteria into this already complex system will make it increasingly chaotic reflecting its unpredictable behavior.

  20. Inter-annual Variability in Global Suspended Particulate Inorganic Carbon Inventory Using Space-based Measurements

    Science.gov (United States)

    Hopkins, J.; Balch, W. M.; Henson, S.; Poulton, A. J.; Drapeau, D.; Bowler, B.; Lubelczyk, L.

    2016-02-01

    Coccolithophores, the single celled phytoplankton that produce an outer covering of calcium carbonate coccoliths, are considered to be the greatest contributors to the global oceanic particulate inorganic carbon (PIC) pool. The reflective coccoliths scatter light back out from the ocean surface, enabling PIC concentration to be quantitatively estimated from ocean color satellites. Here we use datasets of AQUA MODIS PIC concentration from 2003-2014 (using the recently-revised PIC algorithm), as well as statistics on coccolithophore vertical distribution derived from cruises throughout the world ocean, to estimate the average global (surface and integrated) PIC standing stock and its associated inter-annual variability. In addition, we divide the global ocean into Longhurst biogeochemical provinces, update the PIC biomass statistics and identify those regions that have the greatest inter-annual variability and thus may exert the greatest influence on global PIC standing stock and the alkalinity pump.

  1. Minimizing inter-microscope variability in dental microwear texture analysis

    Science.gov (United States)

    Arman, Samuel D.; Ungar, Peter S.; Brown, Christopher A.; DeSantis, Larisa R. G.; Schmidt, Christopher; Prideaux, Gavin J.

    2016-06-01

    A common approach to dental microwear texture analysis (DMTA) uses confocal profilometry in concert with scale-sensitive fractal analysis to help understand the diets of extinct mammals. One of the main benefits of DMTA over other methods is the repeatable, objective manner of data collection. This repeatability, however, is threatened by variation in results of DMTA of the same dental surfaces yielded by different microscopes. Here we compare DMTA data of five species of kangaroos measured on seven profilers of varying specifications. Comparison between microscopes confirms that inter-microscope differences are present, but we show that deployment of a number of automated treatments to remove measurement noise can help minimize inter-microscope differences. Applying these same treatments to a published hominin DMTA dataset shows that they alter some significant differences between dietary groups. Minimising microscope variability while maintaining interspecific dietary differences requires then that these factors are balanced in determining appropriate treatments. The process outlined here offers a solution for allowing comparison of data between microscopes, which is essential for ongoing DMTA research. In addition, the process undertaken, including considerations of other elements of DMTA protocols also promises to streamline methodology, remove measurement noise and in doing so, optimize recovery of a reliable dietary signature.

  2. Sensitivity analysis and power for instrumental variable studies.

    Science.gov (United States)

    Wang, Xuran; Jiang, Yang; Zhang, Nancy R; Small, Dylan S

    2018-03-31

    In observational studies to estimate treatment effects, unmeasured confounding is often a concern. The instrumental variable (IV) method can control for unmeasured confounding when there is a valid IV. To be a valid IV, a variable needs to be independent of unmeasured confounders and only affect the outcome through affecting the treatment. When applying the IV method, there is often concern that a putative IV is invalid to some degree. We present an approach to sensitivity analysis for the IV method which examines the sensitivity of inferences to violations of IV validity. Specifically, we consider sensitivity when the magnitude of association between the putative IV and the unmeasured confounders and the direct effect of the IV on the outcome are limited in magnitude by a sensitivity parameter. Our approach is based on extending the Anderson-Rubin test and is valid regardless of the strength of the instrument. A power formula for this sensitivity analysis is presented. We illustrate its usage via examples about Mendelian randomization studies and its implications via a comparison of using rare versus common genetic variants as instruments. © 2018, The International Biometric Society.

  3. Instrumentation and Controls Division, Technical Support Department Management Plan, FY 1993--FY 1996

    Energy Technology Data Exchange (ETDEWEB)

    Adkisson, B.P.; Kunselman, C.W.; Effler, R.P.; Miller, D.R.; Millet, A.J.; Stansberry, C.T.

    1993-08-01

    This report describes the organization, key functions, and major activities of the Technical Support Department The Department is the programmatic support element of the Instrumentation and Controls Division. The Department`s primary focus is the support of existing equipment and systems at Oak Ridge National Laboratory that are generally characterized as instrumentation and controls. The support takes the form of repair, calibration, fabrication, field engineering, preventive maintenance, software support, and record keeping.

  4. Technically upgraded BWR instrumentation lances reduce exposure dose to service personnel

    International Nuclear Information System (INIS)

    Weidenauer, Patrick; Weber, Juergen; Ketteler, Martin

    2009-01-01

    Using the case of modern in-core instrumentation employed in the Kruemmel boiling water reactor the authors show how existing nuclear technology products can be advanced by specific feedback of experience from plant operation and revision activities, and improved upon by technical measures so that the ALARA (as low as reasonably achievable) principle is complied with in an exemplary way. (orig.)

  5. Instrumental variables estimation under a structural Cox model

    DEFF Research Database (Denmark)

    Martinussen, Torben; Nørbo Sørensen, Ditte; Vansteelandt, Stijn

    2017-01-01

    Instrumental variable (IV) analysis is an increasingly popular tool for inferring the effect of an exposure on an outcome, as witnessed by the growing number of IV applications in epidemiology, for instance. The majority of IV analyses of time-to-event endpoints are, however, dominated by heurist...

  6. Customisation of an instrument to assess anaesthesiologists' non-technical skills

    DEFF Research Database (Denmark)

    Jepsen, Rikke M H G; Spanager, Lene; Lyk-Jensen, Helle T

    2015-01-01

    operating room team members: anaes-thesiologists, nurse anaesthetists, surgeons, and scrub nurses. Interviews were transcribed verbatim and analysed using directed content analysis. Anaesthesiologists' non-technical skills were identified, coded, and sorted using the original instrument as a basis......; decision making; team working; and task management. Anaesthesiologists' leadership role in the operating room was emphasised: the original 'Task Management' category was named 'Leadership'. One new element, 'Demonstrating self-awareness' was added under the category 'Situation Awareness'. Compared...

  7. Seasonal and inter-annual variability of the net ecosystem CO2 exchange of a temperate mountain grassland: effects of climate and management.

    Science.gov (United States)

    Wohlfahrt, Georg; Hammerle, Albin; Haslwanter, Alois; Bahn, Michael; Tappeiner, Ulrike; Cernusca, Alexander

    2008-04-27

    The role and relative importance of climate and cutting for the seasonal and inter-annual variability of the net ecosystem CO 2 (NEE) of a temperate mountain grassland was investigated. Eddy covariance CO 2 flux data and associated measurements of the green area index and the major environmental driving forces acquired during 2001-2006 at the study site Neustift (Austria) were analyzed. Driven by three cutting events per year which kept the investigated grassland in a stage of vigorous growth, the seasonal variability of NEE was primarily modulated by gross primary productivity (GPP). The role of environmental parameters in modulating the seasonal variability of NEE was obscured by the strong response of GPP to changes in the amount of green area, as well as the cutting-mediated decoupling of phenological development and the seasonal course of climate drivers. None of the climate and management metrics examined was able to explain the inter-annual variability of annual NEE. This is thought to result from (1) a high covariance between GPP and ecosystem respiration (R eco ) at the annual time scale which results in a comparatively small inter-annual variation of NEE, (2) compensating effects between carbon exchange during and outside the management period, and (3) changes in the biotic response to rather than the climate variables per se. GPP was more important in modulating inter-annual variations in NEE in spring and before the first and second cut, while R eco explained a larger fraction of the inter-annual variability of NEE during the remaining, in particular the post-cut, periods.

  8. Intra-session and inter-session variability of nitric oxide pulmonary diffusing capacity in adults with cystic fibrosis.

    Science.gov (United States)

    Radtke, Thomas; Benden, Christian; Maggi-Beba, Marion; Kriemler, Susi; van der Lee, Ivo; Dressel, Holger

    2017-12-01

    We evaluated the intra-session and inter-session variability of the diffusing capacity of nitric oxide (DLNO), carbon monoxide (DLCO), alveolar-capillary membrane diffusing capacity for carbon monoxide (DMCO) and pulmonary capillary blood volume (Vc) in patients with cystic fibrosis (CF). Patients performed single-breath diffusing capacity measurements during all of 3 consecutive study visits. Precision of gas diffusing parameters was quantified by within-subject standard deviation (SD ws ) and coefficient of variation (CV). Intra-session and inter-session reproducibility was determined by SD ws *2.77. 15 clinically stable patients were included. The intra-session precision of gas diffusing parameters improved over the study visits. The inter-session SD ws for DLNO, DLCO, DMCO, and Vc was 4.8, 1.3, 2.4, and 4.3, respectively. Reproducibility was 13.3, 3.8, 6.7 and 12.0mLmin -1 mmHg -1 ; CV was 4.4, 4.7, 4.4 and 5.8%, respectively. The intra-session variability of DLNO, DLCO, DMCO and Vc improves with breath-hold maneuver training in test-naïve patients with CF, indicating a learning effect. Inter-session reproducibility data are lower than those previously reported in healthy subjects. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Bias and Bias Correction in Multi-Site Instrumental Variables Analysis of Heterogeneous Mediator Effects

    Science.gov (United States)

    Reardon, Sean F.; Unlu, Faith; Zhu, Pei; Bloom, Howard

    2013-01-01

    We explore the use of instrumental variables (IV) analysis with a multi-site randomized trial to estimate the effect of a mediating variable on an outcome in cases where it can be assumed that the observed mediator is the only mechanism linking treatment assignment to outcomes, as assumption known in the instrumental variables literature as the…

  10. Bildungslandschaft or the inter-organizational cooperation network approach (ICNA) as a new approach to attracting pupils to science and technical education

    DEFF Research Database (Denmark)

    Grunwald, Annette; Henriksen, Lars Bo

    2013-01-01

    The paper presents a short review of the literature on attractiveness and argues for the need to consider an inter-organizational cooperation network (ICNA), which organizes out-of-school learning as a necessary and new perspective to promote attractiveness in technical education. The paper offers...

  11. Causal null hypotheses of sustained treatment strategies: What can be tested with an instrumental variable?

    Science.gov (United States)

    Swanson, Sonja A; Labrecque, Jeremy; Hernán, Miguel A

    2018-05-02

    Sometimes instrumental variable methods are used to test whether a causal effect is null rather than to estimate the magnitude of a causal effect. However, when instrumental variable methods are applied to time-varying exposures, as in many Mendelian randomization studies, it is unclear what causal null hypothesis is tested. Here, we consider different versions of causal null hypotheses for time-varying exposures, show that the instrumental variable conditions alone are insufficient to test some of them, and describe additional assumptions that can be made to test a wider range of causal null hypotheses, including both sharp and average causal null hypotheses. Implications for interpretation and reporting of instrumental variable results are discussed.

  12. Thyroid Ultrasound: Change of Inter-observer Variability and Diagnostic Performance after Training

    International Nuclear Information System (INIS)

    Moon, Hee Jung; Kim, Eun Kyung; Kwak, Jin Young; Park, Jeong Seon

    2011-01-01

    To investigate and compare inter-observer variability and diagnostic performance of thyroid ultrasound (US) between a faculty member and observing residents. From October 2007 to June 2009, 18 residents underwent training in thyroid US section. Group 1 included 8 residents that were trained for the first time and group 2 included 10 residents that were trained for the second time. US features of nodules were recorded according to the composition, echogenicity, margin, calcifications, shape, and final assessment by a faculty member and residents, respectively. Following a discussion, a faculty member performed fine needle aspiration. Then, the inter-observer variability and diagnostic performance between a faculty member and residents were investigated and compared for US. In group 1, agreement for composition in resident 1, calcification for residents 5 and 6, and shape for resident 4 were slight, moderate, moderate, and moderate, respectively. In group 2, agreement for composition in residents 1 and 10 were moderate. Substantial or greater agreement was observed more frequently in group 2 than 1. The diagnostic performances for both the faculty and residents were high and not statistically different. Agreement for US features between a faculty and residents as well as diagnostic performance were high. Moreover, diagnostic performance of residents that underwent training a second time of training was higher than residents that underwent training only once

  13. Technical evaluation of available state of Nevada survey instruments

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-02-01

    Argonne National Laboratory (ANL) is reviewing the survey research studies completed by Mountain West Research (1987-1989) for the state of Nevada`s Nuclear Waste Project Office. In this research, 14 survey instruments were used to seek data on whether perceptions of risk could be associated with the possible siting of a high-level radioactive waste repository in Nevada and could be a dominant source of potential, significant, adverse economic impacts. This report presents results from phase 1 of the review, in which ANL contracted with the National Opinion Research Center (NORC) at the University of Chicago to evaluate the technical merits of the nine survey instruments that ANL had been able to acquire. The scope of NORC`s work was limited to rating the questions and stating their strengths and weaknesses. NORC concluded that the surveys could provide valuable data about risk perceptions and potential behavioral responses. NORC identified a few minor problems with a number of questions and the calculated response rates but claimed these problems would probably not have any major biasing effect. The NORC evaluation would have been more complete if the terms used in the questionnaires had been defined, all survey instruments had been acquired, and all data had been made available to the public.

  14. Technical evaluation of available state of Nevada survey instruments

    International Nuclear Information System (INIS)

    1993-02-01

    Argonne National Laboratory (ANL) is reviewing the survey research studies completed by Mountain West Research (1987-1989) for the state of Nevada's Nuclear Waste Project Office. In this research, 14 survey instruments were used to seek data on whether perceptions of risk could be associated with the possible siting of a high-level radioactive waste repository in Nevada and could be a dominant source of potential, significant, adverse economic impacts. This report presents results from phase 1 of the review, in which ANL contracted with the National Opinion Research Center (NORC) at the University of Chicago to evaluate the technical merits of the nine survey instruments that ANL had been able to acquire. The scope of NORC's work was limited to rating the questions and stating their strengths and weaknesses. NORC concluded that the surveys could provide valuable data about risk perceptions and potential behavioral responses. NORC identified a few minor problems with a number of questions and the calculated response rates but claimed these problems would probably not have any major biasing effect. The NORC evaluation would have been more complete if the terms used in the questionnaires had been defined, all survey instruments had been acquired, and all data had been made available to the public

  15. Detecting inter-annual variability in the phenological characteristics of southern Africa’s vegetation using satellite imagery

    CSIR Research Space (South Africa)

    Wessels, Konrad J

    2011-01-01

    Full Text Available provides consistent measurements of vegetation greenness which captures phenological cycles and vegetation function. Understanding the inter-annual variability in phenology is imperative, as phenological changes will be one of the first signs of the impact...

  16. The utilization of performance evaluation instruments by technical trainers to evaluate maintenance personnel in the nuclear power industry in the United States

    International Nuclear Information System (INIS)

    Hornberger, C.K.

    1993-01-01

    The purpose of this study was to document the utilization of performance evaluation instruments by technical trainers in the evaluation of maintenance personnel in US nuclear power plants. Performance evaluation of maintenance personnel has been identified by nuclear utilities and the Nuclear Regulatory Commission as the only acceptable method of determining worker competence. The NRC requires performance evaluation to be conducted to performance standards, but it does not specify the standards or the method to be utilized. Each plant is free to establish its own standards and methods of evaluation. This was a descriptive study utilizing descriptive statistics for the analysis of the data. The subjects included 655 maintenance trainers in 72 US nuclear plants. Conclusions of the study include: (1) Technical trainers are in compliance with NRC regulations. (2) Evaluation materials developed by the Institute of Nuclear Power Operations are used by technical trainers in every one of the 62 plants that responded. (3) In-plant or self-developed Performance Evaluation Instruments are utilized by 419 or 95.2% of the technical trainers. (4) Technical trainers incorporate nine common components into their Performance Evaluation Instruments. (5) Technical trainers evaluate maintenance processes and the product produced by workers when following procedures and specifications are critical and when safety hazards are involved. (6) Technical trainers believe that utilizing Performance Evaluation Instruments makes their job easier by providing documentation about the quality and standards of maintenance skills. (7) Technical trainers believe that maintenance workers benefit when their skills are assessed through the use of Performance Evaluation Instruments

  17. Censored Quantile Instrumental Variable Estimates of the Price Elasticity of Expenditure on Medical Care.

    Science.gov (United States)

    Kowalski, Amanda

    2016-01-02

    Efforts to control medical care costs depend critically on how individuals respond to prices. I estimate the price elasticity of expenditure on medical care using a censored quantile instrumental variable (CQIV) estimator. CQIV allows estimates to vary across the conditional expenditure distribution, relaxes traditional censored model assumptions, and addresses endogeneity with an instrumental variable. My instrumental variable strategy uses a family member's injury to induce variation in an individual's own price. Across the conditional deciles of the expenditure distribution, I find elasticities that vary from -0.76 to -1.49, which are an order of magnitude larger than previous estimates.

  18. Magnetic resonance imaging for prostate bed radiotherapy planning: An inter- and intra-observer variability study

    International Nuclear Information System (INIS)

    Barkati, Maroie; Simard, Dany; Taussky, Daniel; Delouya, Guiula

    2016-01-01

    We assessed the inter- and intra-observer variability in contouring the prostate bed for radiation therapy planning using MRI compared with computed tomography (CT). We selected 15 patients with prior radical prostatectomy. All had CT and MRI simulation for planning purposes. Image fusions were done between CT and MRI. Three radiation oncologists with several years of experience in treating prostate cancer contoured the prostate bed first on CT and then on MRI. Before contouring, each radiation oncologist had to review the Radiation Therapy Oncology Group guidelines for postoperative external beam radiotherapy. The agreement between volumes was calculated using the Dice similarity coefficient (DSC). Analysis was done using the Matlab software. The DSC was compared using non-parametric statistical tests. Contouring on CT alone showed a statistically significant (P = 0.001) higher similarity between observers with a mean DSC of 0.76 (standard deviation ± 0.05) compared with contouring on MRI with a mean of 0.66 (standard deviation ± 0.05). Mean intra-observer variability between CT and MRI was 0.68, 0.75 and 0.78 for the three observers. The clinical target volume was 19 - 74% larger on CT than on MRI. The intra-observer difference in clinical target volume between CT and MRI was statistically significant in two observers and non-significant in the third one (P = 0.09). We found less inter-observer variability when contouring on CT than on MRI. Radiation Therapy Oncology Group contouring guidelines are based on anatomical landmarks readily visible on CT. These landmarks are more inter-observer dependent on MRI. Therefore, present contouring guidelines might not be applicable to MRI planning.

  19. Stability of FDG-PET Radiomics features - An integrated analysis of test-retest and inter-observer variability

    Energy Technology Data Exchange (ETDEWEB)

    Leijenaar, Ralph T. H.; Carvalho, Sara; Rios Velazquez, Emmanuel [Dept. of Radiation Oncology (MAASTRO), GROW-School for Oncology and Developmental Biology, Maastricht Univ. Medical Center, Maastricht (Netherlands)] [and others

    2013-10-15

    Purpose: Besides basic measurements as maximum standardized uptake value (SUV){sub max} or SUV{sub mean} derived from 18F-FDG positron emission tomography (PET) scans, more advanced quantitative imaging features (i.e. 'Radiomics' features) are increasingly investigated for treatment monitoring, outcome prediction, or as potential biomarkers. With these prospected applications of Radiomics features, it is a requisite that they provide robust and reliable measurements. The aim of our study was therefore to perform an integrated stability analysis of a large number of PET-derived features in non-small cell lung carcinoma (NSCLC), based on both a test-retest and an inter-observer setup. Methods: Eleven NSCLC patients were included in the test-retest cohort. Patients underwent repeated PET imaging within a one day interval, before any treatment was delivered. Lesions were delineated by applying a threshold of 50 % of the maximum uptake value within the tumor. Twenty-three NSCLC patients were included in the inter-observer cohort. Patients underwent a diagnostic whole body PET-computed tomography (CT). Lesions were manually delineated based on fused PET-CT, using a standardized clinical delineation protocol. Delineation was performed independently by five observers, blinded to each other. Fifteen first order statistics, 39 descriptors of intensity volume histograms, eight geometric features and 44 textural features were extracted. For every feature, test-retest and inter-observer stability was assessed with the intra-class correlation coefficient (ICC) and the coefficient of variability, normalized to mean and range. Similarity between test-retest and inter-observer stability rankings of features was assessed with Spear man's rank correlation coefficient. Results: Results showed that the majority of assessed features had both a high test-retest (71%) and inter-observer (91%) stability in terms of their ICC. Overall, features more stable in repeated PET

  20. Inter-observer variability in contouring the penile bulb on CT images for prostate cancer treatment planning

    International Nuclear Information System (INIS)

    Perna, Lucia; Cozzarini, Cesare; Maggiulli, Eleonora; Fellin, Gianni; Rancati, Tiziana; Valdagni, Riccardo; Vavassori, Vittorio; Villa, Sergio; Fiorino, Claudio

    2011-01-01

    Several investigations have recently suggested the existence of a correlation between the dose received by the penile bulb (PB) and the risk of erectile dysfunction (ED) after radical radiotherapy for clinically localized prostate carcinoma. A prospective multi-Institute study (DUE-01) was implemented with the aim to assess the predictive parameters of ED. Previously, an evaluation of inter-observer variations of PB contouring was mandatory in order to quantify its impact on PB dose-volume parameters by means of a dummy run exercise. Fifteen observers, from different Institutes, drew the PB on the planning CT images of ten patients; inter-observer variations were analysed in terms of PB volume variation and cranial/caudal limits. 3DCRT treatment plans were simulated to evaluate the impact of PB contouring inter-variability on dose-volume statistics parameters. For DVH analysis the values of PB mean dose and the volume of PB receiving more than 50 Gy and 70 Gy (V50 and V70, respectively) were considered. Systematic differences from the average values were assessed by the Wilcoxon test. Seven observers systematically overestimated or underestimated the PB volume with deviations from the average volumes ranging between -48% and +34% (p < 0.05). The analysis of the cranial and caudal borders showed a prevalence of random over systematic deviations. Inter-observer contouring variability strongly impacts on DVH parameters, although standard deviations of inter-patient differences were larger than inter-observer variations: 14.5 Gy versus 6.8 Gy for mean PB dose, 23.0% versus 11.0% and 16.8% versus 9.3% for V50 and V70 respectively. In conclusion, despite the large inter-observer variation in contouring PB, a large multi-centric study may have the possibility to detect a possible correlation between PB % dose-volume parameters and ED. The impact of contouring uncertainty could be reduced by 'a posteriori' contouring from a single observer or by introducing

  1. [Inter-and intra-operator variability in the analysis of semen parameters: results from a quality control program].

    Science.gov (United States)

    Daoud, Salima; Chakroun-Feki, Nozha; Sellami, Afifa; Ammar-Keskes, Leila; Rebai, Tarek

    2016-01-01

    Semen analysis is a key part of male infertility investigation. The necessity of quality management implementation in the andrology laboratory has been recognized in order to ensure the reliability of its results. The aim of this study was to evaluate intra- and inter-individual variability in the assessment of semen parameters in our laboratory through a quality control programme. Four participants from the laboratory with different experience levels have participated in this study. Semen samples of varying quality were assessed for sperm motility, concentration and morphology and the results were used to evaluate inter-participant variability. In addition, replicates of each semen sample were analyzed to determine intra-individual variability for semen parameters analysis. The average values of inter-participant coefficients of variation for sperm motility, concentration and morphology were 12.8%, 19.8% and 48.9% respectively. The mean intra-participant coefficients of variation were, respectively, 6.9%, 12.3% and 42.7% for sperm motility, concentration and morphology. Despite some random errors of under- or overestimation, the overall results remained within the limits of acceptability for all participants. Sperm morphology assessment was particularly influenced by the participant's level of experience. The present data emphasize the need for appropriate training of the laboratory staff and for regular participation in internal quality control programmes in order to improve the reliability of laboratory results.

  2. Instrumental variable estimation of treatment effects for duration outcomes

    NARCIS (Netherlands)

    G.E. Bijwaard (Govert)

    2007-01-01

    textabstractIn this article we propose and implement an instrumental variable estimation procedure to obtain treatment effects on duration outcomes. The method can handle the typical complications that arise with duration data of time-varying treatment and censoring. The treatment effect we

  3. Site-specific 13C content by quantitative isotopic 13C Nuclear Magnetic Resonance spectrometry: A pilot inter-laboratory study

    International Nuclear Information System (INIS)

    Chaintreau, Alain; Fieber, Wolfgang; Sommer, Horst; Gilbert, Alexis; Yamada, Keita; Yoshida, Naohiro; Pagelot, Alain; Moskau, Detlef; Moreno, Aitor; Schleucher, Jürgen; Reniero, Fabiano; Holland, Margaret; Guillou, Claude; Silvestre, Virginie; Akoka, Serge; Remaud, Gérald S.

    2013-01-01

    Graphical abstract: -- Highlights: •First ring test on isotopic 13 C NMR spectrometry. •Evaluation of the intra- and inter-variability of the NMR spectrometers used. •Definition of a protocol for qualification of the performance of the spectrometer. -- Abstract: Isotopic 13 C NMR spectrometry, which is able to measure intra-molecular 13 C composition, is of emerging demand because of the new information provided by the 13 C site-specific content of a given molecule. A systematic evaluation of instrumental behaviour is of importance to envisage isotopic 13 C NMR as a routine tool. This paper describes the first collaborative study of intra-molecular 13 C composition by NMR. The main goals of the ring test were to establish intra- and inter-variability of the spectrometer response. Eight instruments with different configuration were retained for the exercise on the basis of a qualification test. Reproducibility at the natural abundance of isotopic 13 C NMR was then assessed on vanillin from three different origins associated with specific δ 13 C i profiles. The standard deviation was, on average, between 0.9 and 1.2‰ for intra-variability. The highest standard deviation for inter-variability was 2.1‰. This is significantly higher than the internal precision but could be considered good in respect of a first ring test on a new analytical method. The standard deviation of δ 13 C i in vanillin was not homogeneous over the eight carbons, with no trend either for the carbon position or for the configuration of the spectrometer. However, since the repeatability for each instrument was satisfactory, correction factors for each carbon in vanillin could be calculated to harmonize the results

  4. Initial Validation of a Technical Writing Rubric for Engineering Design

    Directory of Open Access Journals (Sweden)

    Cheryl Bodnar

    2018-02-01

    Full Text Available Engineering design serves as the capstone experience of most undergraduate engineering programs. One of the key elements of the engineering design process is the compilation of results obtained into a technical report that can be shared and distributed to interested stakeholders including industry, faculty members and other relevant parties. In an effort to expand the tools available for assessment of engineering design technical reports, this study performed an initial validation of a previously developed Technical Writing rubric. The rubric was evaluated for its reliability to measure the intended construct, inter-rater reliability and external validity in comparison to an existing generalized written communication rubric. It was found that the rubric was reliable with Cronbach’s alpha for all dimensions between 0.817 and 0.976. The inter-rater reliability for the overall instrument was also found to be excellent at 0.85. Finally, it was observed that there were no statistically significant differences observed between the measurements obtained on the Technical Writing rubric in comparison to the more generalized Written Communication Value rubric. This demonstrates that although specific to engineering design environments the Technical Writing rubric was able to measure key constructs associated with written communication practice. This rubric can now serve as one additional tool for assessment of communication skills within engineering capstone design experiences.

  5. 47 CFR 25.279 - Inter-satellite service.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Inter-satellite service. 25.279 Section 25.279 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES SATELLITE COMMUNICATIONS Technical Operations § 25.279 Inter-satellite service. (a) Any satellite communicating with other space...

  6. Longitudinal Surveys of Australian Youth (LSAY): Derived Variables. Technical Report 64

    Science.gov (United States)

    National Centre for Vocational Education Research (NCVER), 2012

    2012-01-01

    This technical report describes the 24 derived variables developed for users of the Longitudinal Surveys of Australian Youth (LSAY) data. The variables fall into the categories education, employment and social, and help to simplify the complexity of the LSAY data by providing useful indicators for analysis. To help LSAY data users understand and…

  7. Patterns and controls of inter-annual variability in the terrestrial carbon budget

    Directory of Open Access Journals (Sweden)

    B. Marcolla

    2017-08-01

    Full Text Available The terrestrial carbon fluxes show the largest variability among the components of the global carbon cycle and drive most of the temporal variations in the growth rate of atmospheric CO2. Understanding the environmental controls and trends of the terrestrial carbon budget is therefore essential to predict the future trajectories of the CO2 airborne fraction and atmospheric concentrations. In the present work, patterns and controls of the inter-annual variability (IAV of carbon net ecosystem exchange (NEE have been analysed using three different data streams: ecosystem-level observations from the FLUXNET database (La Thuile and 2015 releases, the MPI-MTE (model tree ensemble bottom–up product resulting from the global upscaling of site-level fluxes, and the Jena CarboScope Inversion, a top–down estimate of surface fluxes obtained from observed CO2 concentrations and an atmospheric transport model. Consistencies and discrepancies in the temporal and spatial patterns and in the climatic and physiological controls of IAV were investigated between the three data sources. Results show that the global average of IAV at FLUXNET sites, quantified as the standard deviation of annual NEE, peaks in arid ecosystems and amounts to  ∼  120 gC m−2 y−1, almost 6 times more than the values calculated from the two global products (15 and 20 gC m−2 y−1 for MPI-MTE and the Jena Inversion, respectively. Most of the temporal variability observed in the last three decades of the MPI-MTE and Jena Inversion products is due to yearly anomalies, whereas the temporal trends explain only about 15 and 20 % of the variability, respectively. Both at the site level and on a global scale, the IAV of NEE is driven by the gross primary productivity and in particular by the cumulative carbon flux during the months when land acts as a sink. Altogether these results offer a broad view on the magnitude, spatial patterns and environmental drivers of IAV

  8. SU-G-206-07: Dual-Energy CT Inter- and Intra-Scanner Variability Within One Make and Model

    International Nuclear Information System (INIS)

    Jacobsen, M; Wood, C; Cody, D

    2016-01-01

    Purpose: It can be logistically quite difficult to scan patients on the same exact device for their repeat visits in multi-scanner facilities. The reliability between dual-energy CT scanners’ quantitative results is not known, nor is their individual repeatability. Therefore, we evaluated inter- and intra-scanner variability with respect to several key clinical quantitative metrics specific to dual-energy CT. Methods: Eleven identical GE HD-750 CT scanners in a busy clinical environment were used to perform dual-energy (DE) CT scans of a large elliptical quality control (QC) phantom (Gammex, Inc.; Middleton, WI) which contains many standard insert materials. The DE-QC phantom was scanned bi-weekly during 2016; 3 to 4 scans were obtained from each scanner (a total of 35 data sets were used for analysis). Iodine accuracy for the 2mg/ml, 5mg/ml and 15mg/ml rods (from the Iodine(Water) image set) and soft tissue HU (40 HU based on NIST constants) from the 50keV data set were used to assess inter- and intra-scanner variability (standard deviation). Results: Intra-scanner variability average for 2mg/ml Iodine was 0.10 mg/ml (range 0.05–0.15 mg/ml), for 5mg/ml Iodine was 0.12 mg/ml (range 0.07–0.16 mg/ml), for 15 mg/ml Iodine was 0.25 mg/ml (range 0.16–0.37 mg/ml), and for the soft tissue inserts was 2.1 HU (range 1.8–2.6 HU). Inter-scanner variability average for 2mg/ml Iodine was 0.16 mg/ml (range 0.11–0.19 mg/ml), for 5mg/ml Iodine was 0.18 mg/ml (range 0.11–0.22 mg/ml), for 15 mg/ml Iodine was 0.35 mg/ml (range 0.23–0.44 mg/ml), and for the soft tissue inserts was 3.8 HU (range 3.1–4.5 HU). Conclusion: Intra-scanner variability for the iodine and soft tissue inserts averaged 3.1% and 5.2% respectively, and inter-scanner variability for these regions analyzed averaged 5.0% and 9.5%, respectively. Future work will include determination of smallest measurable change and acceptable limits for DE-CT scanner variability over longer time intervals. This

  9. Technical Training: Technical Training Seminar

    CERN Multimedia

    2004-01-01

    Tuesday 30 March TECHNICAL TRAINING SEMINAR From 9:00 to 12:00 and from 13:00 to 16:00 hrs - Council Chamber, Salle B, Salle des Pas Perdus National Instruments (NI) on Tour 2004 Claudia Jüngel, Evrem Yarkin, Joel Clerc, Hervé Baour / NATIONAL INSTRUMENTS The special event NI on Tour 2004, run in Germany, Austria and Switzerland, will be at CERN on March 30. Technical seminars and free introductory courses will be offered all day long in the Council Chamber, Salle B, and Salle des Pas Perdus (buildings 61 and 503). Technical conferences: 09:00 - 12:00 Data acquisition systems on PCs. Industrial measurement and control techniques. 13:00 - 16:00 Advanced LabVIEW software and PXI instrumentation. Measuring instruments and system components for teststand automation. Introductory courses: 09:00 - 12:00 DIAdem: Data analysis and presentation 13:00 - 16:00 Data acquisition with LabVIEW Language: English and French Free special seminar. Registration is recommended with National Instruments Switzerland (please sp...

  10. Technical Training: Technical Training Seminar

    CERN Multimedia

    2004-01-01

    Tuesday 30 March TECHNICAL TRAINING SEMINAR From 9:00 to 12:00 and from 13:00 to 16:00 hrs - Council Chamber, Salle B, Salle des Pas Perdus National Instruments (NI) on Tour 2004 Claudia Jüngel, Evrem Yarkin, Joel Clerc, Hervé Baour / NATIONAL INSTRUMENTS The special event NI on Tour 2004, run in Germany, Austria and Switzerland, will be at CERN on March 30. Technical seminars and free introductory courses will be offered all day long in the Council Chamber, Salle B, and Salle des Pas Perdus (buildings 61 and 503). Technical conferences: 09:00 - 12:00 Data acquisition systems on PCs. Industrial measurement and control techniques. 13:00 - 16:00 Advanced LabVIEW software and PXI instrumentation. Measuring instruments and system components for teststand automation. Introductory courses: 09:00 - 12:00 DIAdem: Data analysis and presentation 13:00 - 16:00 Data acquisition with LabVIEW Language: English and French Free special seminar. Registration is recommended with National Instruments Swi...

  11. Overview of intercalibration of satellite instruments

    Science.gov (United States)

    Chander, G.; Hewison, T.J.; Fox, N.; Wu, X.; Xiong, X.; Blackwell, W.J.

    2013-01-01

    Inter-calibration of satellite instruments is critical for detection and quantification of changes in the Earth’s environment, weather forecasting, understanding climate processes, and monitoring climate and land cover change. These applications use data from many satellites; for the data to be inter-operable, the instruments must be cross-calibrated. To meet the stringent needs of such applications requires that instruments provide reliable, accurate, and consistent measurements over time. Robust techniques are required to ensure that observations from different instruments can be normalized to a common scale that the community agrees on. The long-term reliability of this process needs to be sustained in accordance with established reference standards and best practices. Furthermore, establishing physical meaning to the information through robust Système International d'unités (SI) traceable Calibration and Validation (Cal/Val) is essential to fully understand the parameters under observation. The processes of calibration, correction, stability monitoring, and quality assurance need to be underpinned and evidenced by comparison with “peer instruments” and, ideally, highly calibrated in-orbit reference instruments. Inter-calibration between instruments is a central pillar of the Cal/Val strategies of many national and international satellite remote sensing organizations. Inter-calibration techniques as outlined in this paper not only provide a practical means of identifying and correcting relative biases in radiometric calibration between instruments but also enable potential data gaps between measurement records in a critical time series to be bridged. Use of a robust set of internationally agreed upon and coordinated inter-calibration techniques will lead to significant improvement in the consistency between satellite instruments and facilitate accurate monitoring of the Earth’s climate at uncertainty levels needed to detect and attribute the mechanisms

  12. Instrumented Impact Testing: Influence of Machine Variables and Specimen Position

    International Nuclear Information System (INIS)

    Lucon, E.; McCowan, C. N.; Santoyo, R. A.

    2008-01-01

    An investigation has been conducted on the influence of impact machine variables and specimen positioning on characteristic forces and absorbed energies from instrumented Charpy tests. Brittle and ductile fracture behavior has been investigated by testing NIST reference samples of low, high and super-high energy levels. Test machine variables included tightness of foundation, anvil and striker bolts, and the position of the center of percussion with respect to the center of strike. For specimen positioning, we tested samples which had been moved away or sideways with respect to the anvils. In order to assess the influence of the various factors, we compared mean values in the reference (unaltered) and altered conditions; for machine variables, t-test analyses were also performed in order to evaluate the statistical significance of the observed differences. Our results indicate that the only circumstance which resulted in variations larger than 5 percent for both brittle and ductile specimens is when the sample is not in contact with the anvils. These findings should be taken into account in future revisions of instrumented Charpy test standards.

  13. Instrumented Impact Testing: Influence of Machine Variables and Specimen Position

    Energy Technology Data Exchange (ETDEWEB)

    Lucon, E.; McCowan, C. N.; Santoyo, R. A.

    2008-09-15

    An investigation has been conducted on the influence of impact machine variables and specimen positioning on characteristic forces and absorbed energies from instrumented Charpy tests. Brittle and ductile fracture behavior has been investigated by testing NIST reference samples of low, high and super-high energy levels. Test machine variables included tightness of foundation, anvil and striker bolts, and the position of the center of percussion with respect to the center of strike. For specimen positioning, we tested samples which had been moved away or sideways with respect to the anvils. In order to assess the influence of the various factors, we compared mean values in the reference (unaltered) and altered conditions; for machine variables, t-test analyses were also performed in order to evaluate the statistical significance of the observed differences. Our results indicate that the only circumstance which resulted in variations larger than 5 percent for both brittle and ductile specimens is when the sample is not in contact with the anvils. These findings should be taken into account in future revisions of instrumented Charpy test standards.

  14. InterScience and fusion: Projects, collaborations, and spin-offs

    International Nuclear Information System (INIS)

    Castracane, J.

    1995-01-01

    InterScience, Inc. is a small, high technology research and development company which participates in the mission of the fusion energy research program in a variety of ways. The company specializes in basic physics and advanced technologies applied to research and commercial opportunities. InterScience has numerous federal and private sponsors for research and development activities in plasma physics, electro-optics, materials science, electronics, and biomedical engineering. The company currently has several direct research and development projects which involve the assembly of diagnostic hardware for installation and operation at tokamak facilities both in the U.S. and abroad. In addition, the company works in a technical support capacity for both the magnetic and inertial confinement fusion programs. Successful participation in the Small Business Innovation Research (SBIR) program has provided an avenue for the transfer of expertise from the fusion program to alternate agencies and research areas. Examples of this include fiberoptic sensors with data acquisition systems, advanced spectral imaging and image processing, fiberoptic imaging interferometry for biomedical instrumentation development and, micro-electro-mechanical systems

  15. Developing and Validating the Socio-Technical Model in Ontology Engineering

    Science.gov (United States)

    Silalahi, Mesnan; Indra Sensuse, Dana; Giri Sucahyo, Yudho; Fadhilah Akmaliah, Izzah; Rahayu, Puji; Cahyaningsih, Elin

    2018-03-01

    This paper describes results from an attempt to develop a model in ontology engineering methodology and a way to validate the model. The approach to methodology in ontology engineering is from the point view of socio-technical system theory. Qualitative research synthesis is used to build the model using meta-ethnography. In order to ensure the objectivity of the measurement, inter-rater reliability method was applied using a multi-rater Fleiss Kappa. The results show the accordance of the research output with the diamond model in the socio-technical system theory by evidence of the interdependency of the four socio-technical variables namely people, technology, structure and task.

  16. Comparison of variance estimators for metaanalysis of instrumental variable estimates

    NARCIS (Netherlands)

    Schmidt, A. F.; Hingorani, A. D.; Jefferis, B. J.; White, J.; Groenwold, R. H H; Dudbridge, F.; Ben-Shlomo, Y.; Chaturvedi, N.; Engmann, J.; Hughes, A.; Humphries, S.; Hypponen, E.; Kivimaki, M.; Kuh, D.; Kumari, M.; Menon, U.; Morris, R.; Power, C.; Price, J.; Wannamethee, G.; Whincup, P.

    2016-01-01

    Background: Mendelian randomization studies perform instrumental variable (IV) analysis using genetic IVs. Results of individual Mendelian randomization studies can be pooled through meta-analysis. We explored how different variance estimators influence the meta-analysed IV estimate. Methods: Two

  17. The XRF spectrometer and the selection of analysis conditions (instrumental variables)

    International Nuclear Information System (INIS)

    Willis, J.P.

    2002-01-01

    Full text: This presentation will begin with a brief discussion of EDXRF and flat- and curved-crystal WDXRF spectrometers, contrasting the major differences between the three types. The remainder of the presentation will contain a detailed overview of the choice and settings of the many instrumental variables contained in a modern WDXRF spectrometer, and will discuss critically the choices facing the analyst in setting up a WDXRF spectrometer for different elements and applications. In particular it will discuss the choice of tube target (when a choice is possible), the kV and mA settings, tube filters, collimator masks, collimators, analyzing crystals, secondary collimators, detectors, pulse height selection, X-ray path medium (air, nitrogen, vacuum or helium), counting times for peak and background positions and their effect on counting statistics and lower limit of detection (LLD). The use of Figure of Merit (FOM) calculations to objectively choose the best combination of instrumental variables also will be discussed. This presentation will be followed by a shorter session on a subsequent day entitled - A Selection of XRF Conditions - Practical Session, where participants will be given the opportunity to discuss in groups the selection of the best instrumental variables for three very diverse applications. Copyright (2002) Australian X-ray Analytical Association Inc

  18. Finite-sample instrumental variables inference using an asymptotically pivotal statistic

    NARCIS (Netherlands)

    Bekker, P; Kleibergen, F

    2003-01-01

    We consider the K-statistic, Kleibergen's (2002, Econometrica 70, 1781-1803) adaptation of the Anderson-Rubin (AR) statistic in instrumental variables regression. Whereas Kleibergen (2002) especially analyzes the asymptotic behavior of the statistic, we focus on finite-sample properties in, a

  19. Finite-sample instrumental variables Inference using an Asymptotically Pivotal Statistic

    NARCIS (Netherlands)

    Bekker, P.; Kleibergen, F.R.

    2001-01-01

    The paper considers the K-statistic, Kleibergen’s (2000) adaptation ofthe Anderson-Rubin (AR) statistic in instrumental variables regression.Compared to the AR-statistic this K-statistic shows improvedasymptotic efficiency in terms of degrees of freedom in overidentifiedmodels and yet it shares,

  20. The ITER programme. Successful European inter-governmental cooperation in the scientific and technical fields

    International Nuclear Information System (INIS)

    Haignere, C.; Bigot, B.

    2008-01-01

    At a time when energy questions - be it global warming or the depletion of sources of fossil fuels - are increasingly in the news, nuclear fusion seems, in the very long term, to raise the possibility of providing humanity with virtually inexhaustible energy. Europe is in the forefront of research in this field. It is the leader in a major international collaborative exercise which should lead to the establishment of the International Thermonuclear Experimental Reactor. After a presentation of the issues surrounding fusion, Claudie Haignere and Bernard Bigot, who are closely involved, through their respective activities, in this venture, outline the genesis of the ITER project and the manifold inter-governmental negotiations - both between EU member states and with the other members of the project (Japan, USA, Russia etc.) - that have accompanied its development. Those negotiations led to the signing in November 2006 of a precise cooperation agreement on the ITER programme (with sharing of the financial burden), which came into force in October 2007. ITER (which is to be built at Cadarache in France) thus represents a particularly successful example of inter-governmental cooperation in the scientific and technical fields. For this reason, the authors see it as a model to be followed in many other fields included within the European Research Area (ERA), which the EU intends to develop in the coming years. (authors)

  1. Testing concordance of instrumental variable effects in generalized linear models with application to Mendelian randomization

    Science.gov (United States)

    Dai, James Y.; Chan, Kwun Chuen Gary; Hsu, Li

    2014-01-01

    Instrumental variable regression is one way to overcome unmeasured confounding and estimate causal effect in observational studies. Built on structural mean models, there has been considerale work recently developed for consistent estimation of causal relative risk and causal odds ratio. Such models can sometimes suffer from identification issues for weak instruments. This hampered the applicability of Mendelian randomization analysis in genetic epidemiology. When there are multiple genetic variants available as instrumental variables, and causal effect is defined in a generalized linear model in the presence of unmeasured confounders, we propose to test concordance between instrumental variable effects on the intermediate exposure and instrumental variable effects on the disease outcome, as a means to test the causal effect. We show that a class of generalized least squares estimators provide valid and consistent tests of causality. For causal effect of a continuous exposure on a dichotomous outcome in logistic models, the proposed estimators are shown to be asymptotically conservative. When the disease outcome is rare, such estimators are consistent due to the log-linear approximation of the logistic function. Optimality of such estimators relative to the well-known two-stage least squares estimator and the double-logistic structural mean model is further discussed. PMID:24863158

  2. Inter-Individual Variability in Human Response to Low-Dose Ionizing Radiation, Final Report

    International Nuclear Information System (INIS)

    Rocke, David

    2016-01-01

    In order to investigate inter-individual variability in response to low-dose ionizing radiation, we are working with three models, 1) in-vivo irradiated human skin, for which we have a realistic model, but with few subjects, all from a previous project, 2) ex-vivo irradiated human skin, for which we also have a realistic model, though with the limitations involved in keeping skin pieces alive in media, and 3) MatTek EpiDermFT skin plugs, which provides a more realistic model than cell lines, which is more controllable than human samples.

  3. Inter-Individual Variability in Human Response to Low-Dose Ionizing Radiation, Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Rocke, David [Univ. of California, Davis, CA (United States)

    2016-08-01

    In order to investigate inter-individual variability in response to low-dose ionizing radiation, we are working with three models, 1) in-vivo irradiated human skin, for which we have a realistic model, but with few subjects, all from a previous project, 2) ex-vivo irradiated human skin, for which we also have a realistic model, though with the limitations involved in keeping skin pieces alive in media, and 3) MatTek EpiDermFT skin plugs, which provides a more realistic model than cell lines, which is more controllable than human samples.

  4. Instrument comparison for Aerosolized Titanium Dioxide

    Science.gov (United States)

    Ranpara, Anand

    Recent toxicological studies have shown that the surface area of ultrafine particles (UFP i.e., particles with diameters less than 0.1 micrometer) has a stronger correlation with adverse health effects than does mass of these particles. Ultrafine titanium dioxide (TiO2) particles are widely used in industry, and their use is associated with adverse health outcomes, such as micro vascular dysfunctions and pulmonary damages. The primary aim of this experimental study was to compare a variety of laboratory and industrial hygiene (IH) field study instruments all measuring the same aerosolized TiO2. The study also observed intra-instrument variability between measurements made by two apparently identical devices of the same type of instrument placed side-by-side. The types of instruments studied were (1) DustTrak(TM) DRX, (2) Personal Data RAMs(TM) (PDR), (3) GRIMM, (4) Diffusion charger (DC) and (5) Scanning Mobility Particle Sizer (SMPS). Two devices of each of the four IH field study instrument types were used to measure six levels of mass concentration of fine and ultrafine TiO2 aerosols in controlled chamber tests. Metrics evaluated included real-time mass, active surface area and number/geometric surface area distributions, and off-line gravimetric mass and morphology on filters. DustTrak(TM) DRXs and PDRs were used for mass concentration measurements. DCs were used for active surface area concentration measurements. GRIMMs were used for number concentration measurements. SMPS was used for inter-instrument comparisons of surface area and number concentrations. The results indicated that two apparently identical devices of each DRX and PDR were statistically not different with each other for all the trials of both the sizes of powder (p < 5%). Mean difference between mass concentrations measured by two DustTrak DRX devices was smaller than that measured by two PDR devices. DustTrak DRX measurements were closer to the reference method, gravimetric mass concentration

  5. Estimating inter-annual variability in winter wheat sowing dates from satellite time series in Camargue, France

    Science.gov (United States)

    Manfron, Giacinto; Delmotte, Sylvestre; Busetto, Lorenzo; Hossard, Laure; Ranghetti, Luigi; Brivio, Pietro Alessandro; Boschetti, Mirco

    2017-05-01

    Crop simulation models are commonly used to forecast the performance of cropping systems under different hypotheses of change. Their use on a regional scale is generally constrained, however, by a lack of information on the spatial and temporal variability of environment-related input variables (e.g., soil) and agricultural practices (e.g., sowing dates) that influence crop yields. Satellite remote sensing data can shed light on such variability by providing timely information on crop dynamics and conditions over large areas. This paper proposes a method for analyzing time series of MODIS satellite data in order to estimate the inter-annual variability of winter wheat sowing dates. A rule-based method was developed to automatically identify a reliable sample of winter wheat field time series, and to infer the corresponding sowing dates. The method was designed for a case study in the Camargue region (France), where winter wheat is characterized by vernalization, as in other temperate regions. The detection criteria were chosen on the grounds of agronomic expertise and by analyzing high-confidence time-series vegetation index profiles for winter wheat. This automatic method identified the target crop on more than 56% (four-year average) of the cultivated areas, with low commission errors (11%). It also captured the seasonal variability in sowing dates with errors of ±8 and ±16 days in 46% and 66% of cases, respectively. Extending the analysis to the years 2002-2012 showed that sowing in the Camargue was usually done on or around November 1st (±4 days). Comparing inter-annual sowing date variability with the main local agro-climatic drivers showed that the type of preceding crop and the weather conditions during the summer season before the wheat sowing had a prominent role in influencing winter wheat sowing dates.

  6. Finite-sample instrumental variables inference using an asymptotically pivotal statistic

    NARCIS (Netherlands)

    Bekker, Paul A.; Kleibergen, Frank

    2001-01-01

    The paper considers the K-statistic, Kleibergen’s (2000) adaptation of the Anderson-Rubin (AR) statistic in instrumental variables regression. Compared to the AR-statistic this K-statistic shows improved asymptotic efficiency in terms of degrees of freedom in overidenti?ed models and yet it shares,

  7. Instrumentation and electrical program at the Three Mile Island Unit 2, Technical Integration Office

    International Nuclear Information System (INIS)

    Hecker, L.A.

    1982-01-01

    The Three Mile Island Unit 2 accident of March 28, 1979 presents unique research opportunities that can provide valuable information on nuclear power plant safety philosophy and safety systems performance. The Technical Integration Office at Three Mile Island was established by the Department of Energy to manage a broad-based research and development program. One significant part of this effort is the Instrumentation and Electrical Program, which operates: (1) to identify instruments and electrical components that failed during or since the accident; (2) to test and analyze them in order to identify the causes of failure; and (3) to assess the survivability of those that did not fail. The basis for selection of equipment is discussed, and the testing methodology is described. Also, some results of Instrumentation and Electrical Program work to date are presented

  8. Seasonal and inter-annual turbidity variability in the Rio de la Plata from 15 years of MODIS: El Niño dilution effect

    OpenAIRE

    Dogliotti, A.I.; Ruddick, K.; Guerrero, R.

    2016-01-01

    Spatio-temporal variability of turbidity in the Río de la Plata (RdP) estuary (Argentina) at seasonal and inter-annual timescales is analyzed from 15 years (2000–2014) of MODIS data and explained in terms of river discharges and the El Niño Southern Oscillation (ENSO). Satellite estimates were first validated using in situ turbidity measurements and then the time series of monthly averages were analyzed to assess the seasonal and inter-annual variability of turbidity. A strong seasonal variab...

  9. Site-specific {sup 13}C content by quantitative isotopic {sup 13}C Nuclear Magnetic Resonance spectrometry: A pilot inter-laboratory study

    Energy Technology Data Exchange (ETDEWEB)

    Chaintreau, Alain; Fieber, Wolfgang; Sommer, Horst [Firmenich SA, Corporate R and D Division, P.O. Box 239, 1211 Geneva 8 (Switzerland); Gilbert, Alexis; Yamada, Keita [Department of Environmental Chemistry and Engineering, Tokyo Institute of Technology, 4259 Nagatsuta-cho, Midori-ku, Yokohama, Kanagawa 226-8503 (Japan); Yoshida, Naohiro [Department of Environmental Chemistry and Engineering, Tokyo Institute of Technology, 4259 Nagatsuta-cho, Midori-ku, Yokohama, Kanagawa 226-8503 (Japan); Earth-Life Science Institute, Tokyo Institute of Technology, Meguro, Tokyo 152-8551 (Japan); Pagelot, Alain [Bruker Biospin SAS, 34 rue de l‘Industrie, 67166 Wissembourg Cedex (France); Moskau, Detlef; Moreno, Aitor [Bruker Biospin AG, Industriestrasse 26, 8117 Fällanden (Switzerland); Schleucher, Jürgen [Department of Medical Biochemistry and Biophysics, Umeå University, S-90187 Umeå (Sweden); Reniero, Fabiano; Holland, Margaret; Guillou, Claude [European Commission, Joint Research Centre – Institute for Health and Consumer Protection, via E. Fermi 2749, I-21027 Ispra (Italy); Silvestre, Virginie; Akoka, Serge [EBSI team, Interdisciplinary Chemistry: Synthesis, Analysis, Modelling (CEISAM), University of Nantes-CNRS UMR 6230, 2 rue de la Houssinière, BP 92208, F-44322 Nantes cedex 3 (France); Remaud, Gérald S., E-mail: gerald.remaud@univ-nantes.fr [EBSI team, Interdisciplinary Chemistry: Synthesis, Analysis, Modelling (CEISAM), University of Nantes-CNRS UMR 6230, 2 rue de la Houssinière, BP 92208, F-44322 Nantes cedex 3 (France)

    2013-07-25

    Graphical abstract: -- Highlights: •First ring test on isotopic {sup 13}C NMR spectrometry. •Evaluation of the intra- and inter-variability of the NMR spectrometers used. •Definition of a protocol for qualification of the performance of the spectrometer. -- Abstract: Isotopic {sup 13}C NMR spectrometry, which is able to measure intra-molecular {sup 13}C composition, is of emerging demand because of the new information provided by the {sup 13}C site-specific content of a given molecule. A systematic evaluation of instrumental behaviour is of importance to envisage isotopic {sup 13}C NMR as a routine tool. This paper describes the first collaborative study of intra-molecular {sup 13}C composition by NMR. The main goals of the ring test were to establish intra- and inter-variability of the spectrometer response. Eight instruments with different configuration were retained for the exercise on the basis of a qualification test. Reproducibility at the natural abundance of isotopic {sup 13}C NMR was then assessed on vanillin from three different origins associated with specific δ{sup 13}C{sub i} profiles. The standard deviation was, on average, between 0.9 and 1.2‰ for intra-variability. The highest standard deviation for inter-variability was 2.1‰. This is significantly higher than the internal precision but could be considered good in respect of a first ring test on a new analytical method. The standard deviation of δ{sup 13}C{sub i} in vanillin was not homogeneous over the eight carbons, with no trend either for the carbon position or for the configuration of the spectrometer. However, since the repeatability for each instrument was satisfactory, correction factors for each carbon in vanillin could be calculated to harmonize the results.

  10. Assessing the inter- and intra-animal variability of in vivo OsteoProbe skeletal measures in untreated dogs

    Directory of Open Access Journals (Sweden)

    Erin M.B. McNerny

    2016-12-01

    Full Text Available The OsteoProbe is a second-generation reference point indentation (RPI device without a reference probe that is designed to simplify RPI testing for clinical use. Successful clinical implementation of the OsteoProbe would benefit from a better understanding of how its output, bone material strength index (BMSi, relates to the material properties of bone and under what conditions it reliably correlates with fracture risk. Large animal models have the potential to help fill this knowledge gap, as cadaveric studies are retrospective and limited by incomplete patient histories (including the potential use of bone matrix altering drugs such as bisphosphonates. The goal of this study was to assess the intra and inter-animal variability of OsteoProbe measures in untreated beagle dogs (n = 12, and to evaluate this variability in comparison to traditional mechanical testing. OsteoProbe measurements were performed in vivo on the left tibia of each dog and repeated 6 months later on the day of sacrifice. Within-animal variation of BMSi (CV of 5–10 indents averaged 8.9 and 9.0% at the first and second timepoints, respectively. In contrast, inter-animal variation of BMSi increased from 5.3% to 9.1%. The group variation of BMSi was on par with that of traditional 3-point mechanical testing; inter-animal variation was 10% for ultimate force, 13% for stiffness, and 12% for total work as measured on the femur. There was no significant change in mean BMSi after 6 months, but the individual change with time across the 12 dogs was highly variable, ranging from −12.4% to +21.7% (mean 1.6%, SD 10.6%. No significant correlations were found between in vivo tibia BMSi and femur mechanical properties measured by ex vivo 3-pt bending, but this may be a limitation of sample size or the tests being performed on different bones. No relationship was found between BMSi and tissue mineral density, but a strong positive correlation was found between BMSi and tibia

  11. 47 CFR 25.272 - General inter-system coordination procedures.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false General inter-system coordination procedures. 25.272 Section 25.272 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES SATELLITE COMMUNICATIONS Technical Operations § 25.272 General inter-system coordination...

  12. Inter-individual variability in the production of flavan-3-ol colonic metabolites: preliminary elucidation of urinary metabotypes.

    Science.gov (United States)

    Mena, Pedro; Ludwig, Iziar A; Tomatis, Virginia B; Acharjee, Animesh; Calani, Luca; Rosi, Alice; Brighenti, Furio; Ray, Sumantra; Griffin, Julian L; Bluck, Les J; Del Rio, Daniele

    2018-04-03

    There is much information on the bioavailability of (poly)phenolic compounds following acute intake of various foods. However, there are only limited data on the effects of repeated and combined exposure to specific (poly)phenol food sources and the inter-individual variability in their bioavailability. This study evaluated the combined urinary excretion of (poly)phenols from green tea and coffee following daily consumption by healthy subjects in free-living conditions. The inter-individual variability in the production of phenolic metabolites was also investigated. Eleven participants consumed both tablets of green tea and green coffee bean extracts daily for 8 weeks and 24-h urine was collected on five different occasions. The urinary profile of phenolic metabolites and a set of multivariate statistical tests were used to investigate the putative existence of characteristic metabotypes in the production of flavan-3-ol microbial metabolites. (Poly)phenolic compounds in the green tea and green coffee bean extracts were absorbed and excreted after simultaneous consumption, with green tea resulting in more inter-individual variability in urinary excretion of phenolic metabolites. Three metabotypes in the production of flavan-3-ol microbial metabolites were tentatively defined, characterized by the excretion of different amounts of trihydroxyphenyl-γ-valerolactones, dihydroxyphenyl-γ-valerolactones, and hydroxyphenylpropionic acids. The selective production of microbiota-derived metabolites from flavan-3-ols and the putative existence of characteristic metabotypes in their production represent an important development in the study of the bioavailability of plant bioactives. These observations will contribute to better understand the health effects and individual differences associated with consumption of flavan-3-ols, arguably the main class of flavonoids in the human diet.

  13. Non-technical skills evaluation in the critical care air ambulance environment: introduction of an adapted rating instrument--an observational study.

    Science.gov (United States)

    Myers, Julia A; Powell, David M C; Psirides, Alex; Hathaway, Karyn; Aldington, Sarah; Haney, Michael F

    2016-03-08

    In the isolated and dynamic health-care setting of critical care air ambulance transport, the quality of clinical care is strongly influenced by non-technical skills such as anticipating, recognising and understanding, decision making, and teamwork. However there are no published reports identifying or applying a non-technical skills framework specific to an intensive care air ambulance setting. The objective of this study was to adapt and evaluate a non-technical skills rating framework for the air ambulance clinical environment. In the first phase of the project the anaesthetists' non-technical skills (ANTS) framework was adapted to the air ambulance setting, using data collected directly from clinician groups, published literature, and field observation. In the second phase experienced and inexperienced inter-hospital transport clinicians completed a simulated critical care air transport scenario, and their non-technical skills performance was independently rated by two blinded assessors. Observed and self-rated general clinical performance ratings were also collected. Rank-based statistical tests were used to examine differences in the performance of experienced and inexperienced clinicians, and relationships between different assessment approaches and assessors. The framework developed during phase one was referred to as an aeromedical non-technical skills framework, or AeroNOTS. During phase two 16 physicians from speciality training programmes in intensive care, emergency medicine and anaesthesia took part in the clinical simulation study. Clinicians with inter-hospital transport experience performed more highly than those without experience, according to both AeroNOTS non-technical skills ratings (p = 0.001) and general performance ratings (p = 0.003). Self-ratings did not distinguish experienced from inexperienced transport clinicians (p = 0.32) and were not strongly associated with either observed general performance (r(s) = 0.4, p = 0

  14. Inter-annual variabilities in biogeophysical feedback of terrestrial ecosystem to atmosphere using a land surface model

    Science.gov (United States)

    Seo, C.; Hong, S.; Jeong, H. M.; Jeon, J.

    2017-12-01

    Biogeophysical processes of terrestrial ecosystem such as water vapor and energy flux are the key features to understand ecological feedback to atmospheric processes and thus role of terrestrial ecosystem in climate system. For example, it has been recently known that the ecological feedback through water vapor and energy flux results in regulating regional weathers and climates which is one of the fundamental functions of terrestrial ecosystem. In regional scale, water vapor flux has been known to give negative feedback to atmospheric warming, while energy flux from the surface has been known to positive feedback. In this study, we explored the inter-annual variabilities in these two biogeophysical features to see how the climate regulating functions of terrestrial ecosystem have been changed with climate change. We selected a land surface model involving vegetation dynamics that is forced by atmospheric data from NASA including precipitation, temperature, wind, surface pressure, humidity, and incoming radiations. From the land surface model, we simulated 60-year water vapor and energy fluxes from 1961 to 2010, and calculates feedbacks of terrestrial ecosystem as in radiation amount into atmosphere. Then, we analyzed the inter-annual variabilities in the feedbacks. The results showed that some mid-latitude areas showing very high variabilities in precipitation showed higher positive feedback and/or lower negative feedback. These results suggest deterioration of the biogeophyisical factor of climate regulating function over those regions.

  15. Inter- and Intra-individual Variability in Response to Transcranial Direct Current Stimulation (tDCS) at Varying Current Intensities.

    Science.gov (United States)

    Chew, Taariq; Ho, Kerrie-Anne; Loo, Colleen K

    2015-01-01

    Translation of transcranial direct current stimulation (tDCS) from research to clinical practice is hindered by a lack of consensus on optimal stimulation parameters, significant inter-individual variability in response, and in sufficient intra-individual reliability data. Inter-individual differences in response to anodal tDCS at a range of current intensities were explored. Intra-individual reliability in response to anodal tDCS across two identical sessions was also investigated. Twenty-nine subjects participated in a crossover study. Anodal-tDCS using four different current intensities (0.2, 0.5, 1 and 2 mA), with an anode size of 16 cm2, was tested. The 0.5 mA condition was repeated to assess intra-individual variability. TMS was used to elicit 40 motor-evoked potentials (MEPs) before 10 min of tDCS, and 20 MEPs at four time-points over 30 min following tDCS. ANOVA revealed no main effect of TIME for all conditions except the first 0.5 mA condition, and no differences in response between the four current intensities. Cluster analysis identified two clusters for the 0.2 and 2 mA conditions only. Frequency distributions based on individual subject responses (excitatory, inhibitory or no response) to each condition indicate possible differential responses between individuals to different current intensities. Test-retest reliability was negligible (ICC(2,1) = -0.50). Significant inter-individual variability in response to tDCS across a range of current intensities was found. 2 mA and 0.2 mA tDCS were most effective at inducing a distinct response. Significant intra-individual variability in response to tDCS was also found. This has implications for interpreting results of single-session tDCS experiments. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  16. The effect of patient satisfaction with pharmacist consultation on medication adherence: an instrumental variable approach

    Directory of Open Access Journals (Sweden)

    Gu NY

    2008-12-01

    Full Text Available There are limited studies on quantifying the impact of patient satisfaction with pharmacist consultation on patient medication adherence. Objectives: The objective of this study is to evaluate the effect of patient satisfaction with pharmacist consultation services on medication adherence in a large managed care organization. Methods: We analyzed data from a patient satisfaction survey of 6,916 patients who had used pharmacist consultation services in Kaiser Permanente Southern California from 1993 to 1996. We compared treating patient satisfaction as exogenous, in a single-equation probit model, with a bivariate probit model where patient satisfaction was treated as endogenous. Different sets of instrumental variables were employed, including measures of patients' emotional well-being and patients' propensity to fill their prescriptions at a non-Kaiser Permanente (KP pharmacy. The Smith-Blundell test was used to test whether patient satisfaction was endogenous. Over-identification tests were used to test the validity of the instrumental variables. The Staiger-Stock weak instrument test was used to evaluate the explanatory power of the instrumental variables. Results: All tests indicated that the instrumental variables method was valid and the instrumental variables used have significant explanatory power. The single equation probit model indicated that the effect of patient satisfaction with pharmacist consultation was significant (p<0.010. However, the bivariate probit models revealed that the marginal effect of pharmacist consultation on medication adherence was significantly greater than the single equation probit. The effect increased from 7% to 30% (p<0.010 after controlling for endogeneity bias. Conclusion: After appropriate adjustment for endogeneity bias, patients satisfied with their pharmacy services are substantially more likely to adhere to their medication. The results have important policy implications given the increasing focus

  17. Inter- and intrascanner variability of pulmonary nodule volumetry on low-dose 64-row CT : an anthropomorphic phantom study

    NARCIS (Netherlands)

    Xie, X.; Willemink, M. J.; Zhao, Y.; de Jong, P. A.; van Ooijen, P. M. A.; Oudkerk, M.; Greuter, M. J. W.; Vliegenthart, R.

    Objective: To assess inter- and intrascanner variability in volumetry of solid pulmonary nodules in an anthropomorphic thoracic phantom using low-dose CT. Methods: Five spherical solid artificial nodules [diameters 3, 5, 8, 10 and 12mm; CT density 1100 Hounsfield units (HU)] were randomly placed

  18. Inter Annual Variability of the California Current System and Associated Biochemical Characteristics from Prolonged Data Series

    Science.gov (United States)

    2016-06-01

    and salinity profile data, Moderate Resolution Imaging Spectroradiometer ( MODIS ) that is an instrument deployed on Aqua satellite (A) for surface...data were used specifically to identify the coastal circulations. The data was obtained from Moderate Resolution Imaging Spectroradiometer ( MODIS ), an...surface images are captured in 36 spectral bands at various resolutions, for more specific information on spectral bands see MODIS technical manual on

  19. How plantar exteroceptive efficiency modulates postural and oculomotor control: inter-individual variability

    Directory of Open Access Journals (Sweden)

    Arnaud eFoisy

    2016-05-01

    Full Text Available In a previous experiment, we showed that among young and healthy subjects, thin plantar inserts improve postural control and modify vergence amplitudes. In this experiment, however, significant inter-individual variability was observed. We hypothesize that its origin could be attributed to a different reliance upon feet cutaneous afferents. In order to test this hypothesis, we re-analyzed the data relative to 31 young (age 25,7±3,8 and healthy subjects who participated in the first experiment after having classified them into two groups depending on their Plantar Quotient (PQ = Surface area of CoP foam / Surface area of CoP firm ground x100. Foam decreases the information arising from the feet, normally resulting in a PQ>100. Hence, the PQ provides information on the weight of plantar cutaneous afferents used in postural control. Twelve people were Plantar-Independent Subjects, as indicated by a PQ<100. These individuals did not behave like the Normal Plantar Quotient Subjects: they were almost insensitive to the plantar stimulations in terms of postural control and totally insensitive in terms of oculomotor control. We conclude that the inter-individual variability observed in our first experiment is explained by the subjects’ degree of plantar reliance. We propose that plantar independence is a dysfunctional situation revealing an inefficiency in plantar cutaneous afferents. The latter could be due to a latent somatosensory dysfunction generating a noise which prevents the CNS from correctly processing and using feet somatosensory afferents both for balance and vergence control: Plantar Irritating Stimulus. Considering the non-noxious nature and prevalence of this phenomenon, these results can be of great interest to researchers and clinicians who attempt to trigger postural or oculomotor responses through mechanical stimulation of the foot sole.

  20. Instrumental variables estimation of exposure effects on a time-to-event endpoint using structural cumulative survival models

    DEFF Research Database (Denmark)

    Martinussen, Torben; Vansteelandt, Stijn; Tchetgen Tchetgen, Eric J.

    2017-01-01

    The use of instrumental variables for estimating the effect of an exposure on an outcome is popular in econometrics, and increasingly so in epidemiology. This increasing popularity may be attributed to the natural occurrence of instrumental variables in observational studies that incorporate elem...

  1. Impacts of correcting the inter-variable correlation of climate model outputs on hydrological modeling

    Science.gov (United States)

    Chen, Jie; Li, Chao; Brissette, François P.; Chen, Hua; Wang, Mingna; Essou, Gilles R. C.

    2018-05-01

    Bias correction is usually implemented prior to using climate model outputs for impact studies. However, bias correction methods that are commonly used treat climate variables independently and often ignore inter-variable dependencies. The effects of ignoring such dependencies on impact studies need to be investigated. This study aims to assess the impacts of correcting the inter-variable correlation of climate model outputs on hydrological modeling. To this end, a joint bias correction (JBC) method which corrects the joint distribution of two variables as a whole is compared with an independent bias correction (IBC) method; this is considered in terms of correcting simulations of precipitation and temperature from 26 climate models for hydrological modeling over 12 watersheds located in various climate regimes. The results show that the simulated precipitation and temperature are considerably biased not only in the individual distributions, but also in their correlations, which in turn result in biased hydrological simulations. In addition to reducing the biases of the individual characteristics of precipitation and temperature, the JBC method can also reduce the bias in precipitation-temperature (P-T) correlations. In terms of hydrological modeling, the JBC method performs significantly better than the IBC method for 11 out of the 12 watersheds over the calibration period. For the validation period, the advantages of the JBC method are greatly reduced as the performance becomes dependent on the watershed, GCM and hydrological metric considered. For arid/tropical and snowfall-rainfall-mixed watersheds, JBC performs better than IBC. For snowfall- or rainfall-dominated watersheds, however, the two methods behave similarly, with IBC performing somewhat better than JBC. Overall, the results emphasize the advantages of correcting the P-T correlation when using climate model-simulated precipitation and temperature to assess the impact of climate change on watershed

  2. Intra- and inter-observer variability and accuracy in the determination of linear and angular measurements in computed tomography

    International Nuclear Information System (INIS)

    Christiansen, E.L.; Thompson, J.R.; Kopp, S.

    1986-01-01

    The observer variability and accuracy of linear and angular computed tomography (CT) software measurements in the transaxial plane were investigated for the temporomandibular joint with the General Electric 8800 CT/N Scanner. A dried and measured human mandible was embedded in plastic and scanned in vitro. Sixteen observers participated in the study. The following measurements were tested: inter- and extra-condylar distances, transverse condylar dimension, condylar angulation, and the plastic base of the specimen. Three frozen cadaveric heads were similarly scanned and measured in situ. Intra- and inter-observer variabilities were lowest for the specimen base and highest for condylar angulation. Neuroradiologists had the lowest variability as a group, and the radiology residents and paramedical personell had the highest, but the differences were small. No significant difference was found between CT and macroscopic measurement of the mandible. In situ measurement by CT of condyles with structural changes in the transaxial plane was, however, subject to substantial error. It was concluded that transaxial linear measurements of the condylar processes free of significant structural changes had an error and an accuracy well within acceptable limits. The error for angular measurements was significantly greater than the error for linear measurements

  3. Bayesian methods for meta-analysis of causal relationships estimated using genetic instrumental variables

    DEFF Research Database (Denmark)

    Burgess, Stephen; Thompson, Simon G; Thompson, Grahame

    2010-01-01

    Genetic markers can be used as instrumental variables, in an analogous way to randomization in a clinical trial, to estimate the causal relationship between a phenotype and an outcome variable. Our purpose is to extend the existing methods for such Mendelian randomization studies to the context o...

  4. [Instrumental, directive, and affective communication in hospital leaflets].

    Science.gov (United States)

    Vasconcellos-Silva, Paulo Roberto; Uribe Rivera, Francisco Javier; Castiel, Luis David

    2003-01-01

    This study focuses on the typical semantic systems extracted from hospital staff communicative resources which attempt to validate information as an "object" to be transferred to patients. We describe the models of textual communication in 58 patient information leaflets from five hospital units in Brazil, gathered from 1996 to 2002. Three categories were identified, based on the theory of speech acts (Austin, Searle, and Habermas): 1) cognitive-instrumental utterances: descriptions by means of technical terms validated by self-referred, incomplete, or inaccessible argumentation, with an implicit educational function; 2) technical-directive utterances: self-referred (to the context of the source domains), with a shifting of everyday acts to a technical terrain with a disciplinary function and impersonal features; and 3) expressive modulations: need for inter-subjective connections to strengthen bonds of trust and a tendency to use childish arguments. We conclude that the three categories displayed: fragmentary sources; assumption of univocal messages and invariable use of information (idealized motivations and interests, apart from individualized perspectives); and assumption of universal interests as generators of knowledge.

  5. Longitudinal Surveys of Australian Youth (LSAY): 1995 Cohort Derived Variables. Technical Report 69

    Science.gov (United States)

    National Centre for Vocational Education Research (NCVER), 2012

    2012-01-01

    This technical report details the derived variables developed for users of the Longitudinal Surveys of Australian Youth (LSAY) data. The derived variables fall into the categories education, employment and social, and help to simplify the complexity of the LSAY data by providing useful indicators for analysis. To help LSAY data users understand…

  6. Trend Change Detection in NDVI Time Series: Effects of Inter-Annual Variability and Methodology

    Science.gov (United States)

    Forkel, Matthias; Carvalhais, Nuno; Verbesselt, Jan; Mahecha, Miguel D.; Neigh, Christopher S.R.; Reichstein, Markus

    2013-01-01

    Changing trends in ecosystem productivity can be quantified using satellite observations of Normalized Difference Vegetation Index (NDVI). However, the estimation of trends from NDVI time series differs substantially depending on analyzed satellite dataset, the corresponding spatiotemporal resolution, and the applied statistical method. Here we compare the performance of a wide range of trend estimation methods and demonstrate that performance decreases with increasing inter-annual variability in the NDVI time series. Trend slope estimates based on annual aggregated time series or based on a seasonal-trend model show better performances than methods that remove the seasonal cycle of the time series. A breakpoint detection analysis reveals that an overestimation of breakpoints in NDVI trends can result in wrong or even opposite trend estimates. Based on our results, we give practical recommendations for the application of trend methods on long-term NDVI time series. Particularly, we apply and compare different methods on NDVI time series in Alaska, where both greening and browning trends have been previously observed. Here, the multi-method uncertainty of NDVI trends is quantified through the application of the different trend estimation methods. Our results indicate that greening NDVI trends in Alaska are more spatially and temporally prevalent than browning trends. We also show that detected breakpoints in NDVI trends tend to coincide with large fires. Overall, our analyses demonstrate that seasonal trend methods need to be improved against inter-annual variability to quantify changing trends in ecosystem productivity with higher accuracy.

  7. The Effect of Birth Weight on Academic Performance: Instrumental Variable Analysis.

    Science.gov (United States)

    Lin, Shi Lin; Leung, Gabriel Matthew; Schooling, C Mary

    2017-05-01

    Observationally, lower birth weight is usually associated with poorer academic performance; whether this association is causal or the result of confounding is unknown. To investigate this question, we obtained an effect estimate, which can have a causal interpretation under specific assumptions, of birth weight on educational attainment using instrumental variable analysis based on single nucleotide polymorphisms determining birth weight combined with results from the Social Science Genetic Association Consortium study of 126,559 Caucasians. We similarly obtained an estimate of the effect of birth weight on academic performance in 4,067 adolescents from Hong Kong's (Chinese) Children of 1997 birth cohort (1997-2016), using twin status as an instrumental variable. Birth weight was not associated with years of schooling (per 100-g increase in birth weight, -0.006 years, 95% confidence interval (CI): -0.02, 0.01) or college completion (odds ratio = 1.00, 95% CI: 0.96, 1.03). Birth weight was also unrelated to academic performance in adolescents (per 100-g increase in birth weight, -0.004 grade, 95% CI: -0.04, 0.04) using instrumental variable analysis, although conventional regression gave a small positive association (0.02 higher grade, 95% CI: 0.01, 0.03). Observed associations of birth weight with academic performance may not be causal, suggesting that interventions should focus on the contextual factors generating this correlation. © The Author 2017. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  8. Technical requirements on knowledge base and instrumentation system for decision making in plant operation and maintenance

    International Nuclear Information System (INIS)

    Kitamura, Masaharu; Yoshikawa, Shinji; Hasegawa, Makoto

    1998-03-01

    A series of technical surveys and studies are described in this report to examine and identify technical requirements to be posed on knowledge base and instrumentation system as the fundamental in high reliability computational decision making in operation and maintenance of nuclear power plants. Monitoring and diagnosis are focused as the important tasks among the operation/maintenance-related tasks. A concrete monitoring and diagnosis system configuration has been proposed consisting of distributed symptom database and of on-demand measurement subsystem. An prototype of the proposed system configuration has been successfully verified. (author)

  9. Variabilidade intra-avaliador e inter-avaliadores de medidas antropométricas - DOI: 10.4025/actascihealthsci.v29i1.98 Intra-observer and inter-observers variability of anthropometric measures- DOI: 10.4025/actascihealthsci.v29i1.98

    Directory of Open Access Journals (Sweden)

    Edna Regina de Oliveira

    2007-12-01

    Full Text Available O objetivo do estudo foi avaliar a variabilidade intra e inter-avaliadores de medidas antropométricas realizadas por três antropometristas considerados experientes mediante o cálculo dos erros técnicos de medida (ETM. Para esse fim, foi selecionada uma amostra de 21 voluntários (25,7 ± 7,5 anos, sendo 12 homens e 9 mulheres. Foram consideradas as medidas de peso corporal (kg, estatura (cm, circunferências (cm do braço direito relaxado, abdômen, quadril e coxa, e da espessura das dobras cutâneas (mm tricipital, subescapular, suprailíaca, abdômen, coxa e panturrilha medial. As medidas foram realizadas em 2 dias consecutivos, sempre no período da tarde, envolvendo os mesmos equipamentos e os mesmos voluntários. Os resultados apontaram a ocorrência de ETMs acima dos recomendados para aceitabilidade, tanto a variabilidade intra-avaliador como inter-avaliadores, sugerindo, portanto, a importância e a necessidade de treinamento específico dos antropometristas.The aim of this study was to evaluate the intra and inter-observer reliability in the anthropometric measures of three expert observers through the technical error of measure (TEM. For this end, 21 healthy volunteers (25.7 ± 7.5 years took part in the study, being 12 males and 9 females. The following aspects were analyzed: body weigh (kg, stature (cm, circumferences (cm of relaxed right arm, abdomen, hip and thigh, and skinfold thickness (mm of triceps, subescapular, supra-iliac, abdomen, thigh and calf medial. The measures were made in 2 different days, always in the afternoon, with the same equipments and in the same volunteers. The results pointed the occurrence of TEMs out of the recommended patterns, in both intra-observer and inter-observers variability. This fact showed the importance and need of specific training of the observers.

  10. Designing low-carbon power systems for Great Britain in 2050 that are robust to the spatiotemporal and inter-annual variability of weather

    Science.gov (United States)

    Zeyringer, Marianne; Price, James; Fais, Birgit; Li, Pei-Hao; Sharp, Ed

    2018-05-01

    The design of cost-effective power systems with high shares of variable renewable energy (VRE) technologies requires a modelling approach that simultaneously represents the whole energy system combined with the spatiotemporal and inter-annual variability of VRE. Here, we soft-link a long-term energy system model, which explores new energy system configurations from years to decades, with a high spatial and temporal resolution power system model that captures VRE variability from hours to years. Applying this methodology to Great Britain for 2050, we find that VRE-focused power system design is highly sensitive to the inter-annual variability of weather and that planning based on a single year can lead to operational inadequacy and failure to meet long-term decarbonization objectives. However, some insights do emerge that are relatively stable to weather-year. Reinforcement of the transmission system consistently leads to a decrease in system costs while electricity storage and flexible generation, needed to integrate VRE into the system, are generally deployed close to demand centres.

  11. Measurement of inter- and intra-annual variability of landscape fire activity at a continental scale: The Australian case

    Science.gov (United States)

    Grant J. Williamson; Lynda D. Prior; Matt Jolly; Mark A. Cochrane; Brett P. Murphy; David M. J. S. Bowman

    2016-01-01

    Climate dynamics at diurnal, seasonal and inter-annual scales shape global fire activity, although difficulties of assembling reliable fire and meteorological data with sufficient spatio-temporal resolution have frustrated quantification of this variability. Using Australia as a case study, we combine data from 4760 meteorological stations with 12 years of satellite-...

  12. Measurement of transplanted pancreatic volume using computed tomography: reliability by intra- and inter-observer variability

    International Nuclear Information System (INIS)

    Lundqvist, Eva; Segelsjoe, Monica; Magnusson, Anders; Andersson, Anna; Biglarnia, Ali-Reza

    2012-01-01

    Background Unlike other solid organ transplants, pancreas allografts can undergo a substantial decrease in baseline volume after transplantation. This phenomenon has not been well characterized, as there are insufficient data on reliable and reproducible volume assessments. We hypothesized that characterization of pancreatic volume by means of computed tomography (CT) could be a useful method for clinical follow-up in pancreas transplant patients. Purpose To evaluate the feasibility and reliability of pancreatic volume assessment using CT scan in transplanted patients. Material and Methods CT examinations were performed on 21 consecutive patients undergoing pancreas transplantation. Volume measurements were carried out by two observers tracing the pancreatic contours in all slices. The observers performed the measurements twice for each patient. Differences in volume measurement were used to evaluate intra- and inter-observer variability. Results The intra-observer variability for the pancreatic volume measurements of Observers 1 and 2 was found to be in almost perfect agreement, with an intraclass correlation coefficient (ICC) of 0.90 (0.77-0.96) and 0.99 (0.98-1.0), respectively. Regarding inter-observer validity, the ICCs for the first and second measurements were 0.90 (range, 0.77-0.96) and 0.95 (range, 0.85-0.98), respectively. Conclusion CT volumetry is a reliable and reproducible method for measurement of transplanted pancreatic volume

  13. Measurement of transplanted pancreatic volume using computed tomography: reliability by intra- and inter-observer variability

    Energy Technology Data Exchange (ETDEWEB)

    Lundqvist, Eva; Segelsjoe, Monica; Magnusson, Anders [Uppsala Univ., Dept. of Radiology, Oncology and Radiation Science, Section of Radiology, Uppsala (Sweden)], E-mail: eva.lundqvist.8954@student.uu.se; Andersson, Anna; Biglarnia, Ali-Reza [Dept. of Surgical Sciences, Section of Transplantation Surgery, Uppsala Univ. Hospital, Uppsala (Sweden)

    2012-11-15

    Background Unlike other solid organ transplants, pancreas allografts can undergo a substantial decrease in baseline volume after transplantation. This phenomenon has not been well characterized, as there are insufficient data on reliable and reproducible volume assessments. We hypothesized that characterization of pancreatic volume by means of computed tomography (CT) could be a useful method for clinical follow-up in pancreas transplant patients. Purpose To evaluate the feasibility and reliability of pancreatic volume assessment using CT scan in transplanted patients. Material and Methods CT examinations were performed on 21 consecutive patients undergoing pancreas transplantation. Volume measurements were carried out by two observers tracing the pancreatic contours in all slices. The observers performed the measurements twice for each patient. Differences in volume measurement were used to evaluate intra- and inter-observer variability. Results The intra-observer variability for the pancreatic volume measurements of Observers 1 and 2 was found to be in almost perfect agreement, with an intraclass correlation coefficient (ICC) of 0.90 (0.77-0.96) and 0.99 (0.98-1.0), respectively. Regarding inter-observer validity, the ICCs for the first and second measurements were 0.90 (range, 0.77-0.96) and 0.95 (range, 0.85-0.98), respectively. Conclusion CT volumetry is a reliable and reproducible method for measurement of transplanted pancreatic volume.

  14. ENSO Related Inter-Annual Lightning Variability from the Full TRMM LIS Lightning Climatology

    Science.gov (United States)

    Clark, Austin; Cecil, Daniel

    2018-01-01

    The El Nino/Southern Oscillation (ENSO) contributes to inter-annual variability of lightning production more than any other atmospheric oscillation. This study further investigated how ENSO phase affects lightning production in the tropics and subtropics using the Tropical Rainfall Measuring Mission (TRMM) Lightning Imaging Sensor (LIS). Lightning data were averaged into mean annual warm, cold, and neutral 'years' for analysis of the different phases and compared to model reanalysis data. An examination of the regional sensitivities and preliminary analysis of three locations was conducted using model reanalysis data to determine the leading convective mechanisms in these areas and how they might respond to the ENSO phases

  15. Technical presentation - KEITHLEY Instruments - CANCELLED

    CERN Multimedia

    FI Department

    2009-01-01

    10 March 2009 13:30 – 15:30, Council Chamber, Bldg. 503 Keithley markets highly accurate instruments and data acquisition products, as well as complete system solutions for high-volume production and assembly testing. Keithley Instruments, Inc. designs, develops, manufactures and markets complex electronic instruments and systems geared to the specialized needs of electronics manufacturers for high-performance production testing, process monitoring, product development and research. Products and Services: Digital Multimeters and Data Acquisition Systems Current / Voltage Source and Measure Products Low Current / High Resistance Measurement Products Function/Pulse/Arbitrary/Pattern Generators Low Voltage/Low Resistance Measurement Products RF Spectrum Analyzer / RF Signal Generator / RF Switching Semiconductor Device Characterization Program: Topic 1: Welcome and short overview of new Products SMU 26XXA / ARB Generator 3390 / DMM 3706 / E-Meter 6517B Topic 2a: Te...

  16. Gonioscopy in the dog: inter-examiner variability and the search for a grading scheme.

    Science.gov (United States)

    Oliver, J A C; Cottrell, B C; Newton, J R; Mellersh, C S

    2017-11-01

    To investigate inter-examiner variability in gonioscopic evaluation of pectinate ligament abnormality in dogs and to assess level of inter-examiner agreement for four different gonioscopy grading schemes. Two examiners performed gonioscopy in 98 eyes of 49 Welsh springer spaniel dogs and estimated the percentage circumference of iridocorneal angle affected by pectinate ligament abnormality to the nearest 5%. Percentage scores assigned to each eye by the two examiners were compared. Inter-examiner agreement was assessed following assignment of the percentage scores to each of four grading schemes by Cohen's kappa statistic. There was a strong positive correlation between the results of the two examiners (R=0·91). In general, Examiner 1 scored individual eyes higher than Examiner 2, especially for eyes in which both examiners diagnosed pectinate ligament abnormality. A "good" level of agreement could only be achieved with a gonioscopy grading scheme of no more than three categories and with a relatively large intermediate bandwidth (κ=0·68). A three-tiered grading scheme might represent an improvement on hereditary eye disease schemes which simply classify dogs to be either "affected" or "unaffected" for pectinate ligament abnormality. However, the large intermediate bandwidth of this scheme would only allow for the additional detection of those dogs with marked progression of pectinate ligament abnormality which would be considered most at risk of primary closed-angle glaucoma. © 2017 British Small Animal Veterinary Association.

  17. Chromosomal radiosensitivity: a study of the chromosomal G2 assay in human blood lymphocytes indicating significant inter-individual variability

    International Nuclear Information System (INIS)

    Smart, V.; Curwen, G.B.; Whitehouse, C.A.; Edwards, A.; Tawn, E.J.

    2003-01-01

    The G 2 chromosomal radiosensitivity assay is a technically demanding assay. To ensure that it is reproducible in our laboratory, we have examined the effects of storage and culture conditions by applying the assay to a group of healthy controls and determined the extent of intra- and inter-individual variations. Nineteen different individuals provided one or more blood samples resulting in a total of 57 successful tests. Multiple cultures from a single blood sample showed no statistically significant difference in the number of chromatid type aberrations between cultures. A 24 h delay prior to culturing the lymphocytes did not significantly affect the induced G 2 score. Intra-individual variation was not statistically significant in seven out of nine individuals. Inter-individual variation was highly statistically significant (P<0.001), indicating that there is a real difference between individuals in the response to radiation using this assay

  18. Statistical Analysis for Multisite Trials Using Instrumental Variables with Random Coefficients

    Science.gov (United States)

    Raudenbush, Stephen W.; Reardon, Sean F.; Nomi, Takako

    2012-01-01

    Multisite trials can clarify the average impact of a new program and the heterogeneity of impacts across sites. Unfortunately, in many applications, compliance with treatment assignment is imperfect. For these applications, we propose an instrumental variable (IV) model with person-specific and site-specific random coefficients. Site-specific IV…

  19. Inter-annual variability of the atmospheric carbon dioxide concentrations as simulated with global terrestrial biosphere models and an atmospheric transport model

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, Daisuke; Saeki, Tazu; Nakazawa, Takakiyo [Tohoku Univ., Sendai (Japan). Center for Atmospheric and Oceanic Studies; Ishizawa, Misa; Maksyutov, Shamil [Inst. for Global Change Research, Yokohama (Japan). Frontier Research System for Global Change; Thornton, Peter E. [National Center for Atmospheric Research, Boulder, CO (United States). Climate and Global Dynamics Div.

    2003-04-01

    Seasonal and inter-annual variations of atmospheric CO{sub 2} for the period from 1961 to 1997 have been simulated using a global tracer transport model driven by a new version of the Biome BioGeochemical Cycle model (Biome-BGC). Biome-BGC was forced by daily temperature and precipitation from the NCEP reanalysis dataset, and the calculated monthly-averaged CO{sub 2} fluxes were used as input to the global transport model. Results from an inter-comparison with the Carnegie-Ames-Stanford Approach model (CASA) and the Simulation model of Carbon CYCLE in Land Ecosystems (Sim-CYCLE) model are also reported. The phase of the seasonal cycle in the Northern Hemisphere was reproduced generally well by Biome-BGC, although the amplitude was smaller compared to the observations and to the other biosphere models. The CO{sub 2} time series simulated by Biome-BGC were compared to the global CO{sub 2} concentration anomalies from the observations at Mauna Loa and the South Pole. The modeled concentration anomalies matched the phase of the inter-annual variations in the atmospheric CO{sub 2} observations; however, the modeled amplitude was lower than the observed value in several cases. The result suggests that a significant part of the inter-annual variability in the global carbon cycle can be accounted for by the terrestrial biosphere models. Simulations performed with another climate-based model, Sim-CYCLE, produced a larger amplitude of inter-annual variability in atmospheric CO{sub 2}, making the amplitude closer to the observed range, but with a more visible phase mismatch in a number of time periods. This may indicate the need to increase the Biome-BGC model sensitivity to seasonal and inter-annual changes in temperature and precipitation.

  20. Inter-annual variability of the atmospheric carbon dioxide concentrations as simulated with global terrestrial biosphere models and an atmospheric transport model

    International Nuclear Information System (INIS)

    Fujita, Daisuke; Saeki, Tazu; Nakazawa, Takakiyo; Ishizawa, Misa; Maksyutov, Shamil; Thornton, Peter E.

    2003-01-01

    Seasonal and inter-annual variations of atmospheric CO 2 for the period from 1961 to 1997 have been simulated using a global tracer transport model driven by a new version of the Biome BioGeochemical Cycle model (Biome-BGC). Biome-BGC was forced by daily temperature and precipitation from the NCEP reanalysis dataset, and the calculated monthly-averaged CO 2 fluxes were used as input to the global transport model. Results from an inter-comparison with the Carnegie-Ames-Stanford Approach model (CASA) and the Simulation model of Carbon CYCLE in Land Ecosystems (Sim-CYCLE) model are also reported. The phase of the seasonal cycle in the Northern Hemisphere was reproduced generally well by Biome-BGC, although the amplitude was smaller compared to the observations and to the other biosphere models. The CO 2 time series simulated by Biome-BGC were compared to the global CO 2 concentration anomalies from the observations at Mauna Loa and the South Pole. The modeled concentration anomalies matched the phase of the inter-annual variations in the atmospheric CO 2 observations; however, the modeled amplitude was lower than the observed value in several cases. The result suggests that a significant part of the inter-annual variability in the global carbon cycle can be accounted for by the terrestrial biosphere models. Simulations performed with another climate-based model, Sim-CYCLE, produced a larger amplitude of inter-annual variability in atmospheric CO 2 , making the amplitude closer to the observed range, but with a more visible phase mismatch in a number of time periods. This may indicate the need to increase the Biome-BGC model sensitivity to seasonal and inter-annual changes in temperature and precipitation

  1. Bias and Bias Correction in Multisite Instrumental Variables Analysis of Heterogeneous Mediator Effects

    Science.gov (United States)

    Reardon, Sean F.; Unlu, Fatih; Zhu, Pei; Bloom, Howard S.

    2014-01-01

    We explore the use of instrumental variables (IV) analysis with a multisite randomized trial to estimate the effect of a mediating variable on an outcome in cases where it can be assumed that the observed mediator is the only mechanism linking treatment assignment to outcomes, an assumption known in the IV literature as the exclusion restriction.…

  2. Inter-laboratory analysis of selected genetically modified plant reference materials with digital PCR.

    Science.gov (United States)

    Dobnik, David; Demšar, Tina; Huber, Ingrid; Gerdes, Lars; Broeders, Sylvia; Roosens, Nancy; Debode, Frederic; Berben, Gilbert; Žel, Jana

    2018-01-01

    Digital PCR (dPCR), as a new technology in the field of genetically modified (GM) organism (GMO) testing, enables determination of absolute target copy numbers. The purpose of our study was to test the transferability of methods designed for quantitative PCR (qPCR) to dPCR and to carry out an inter-laboratory comparison of the performance of two different dPCR platforms when determining the absolute GM copy numbers and GM copy number ratio in reference materials certified for GM content in mass fraction. Overall results in terms of measured GM% were within acceptable variation limits for both tested dPCR systems. However, the determined absolute copy numbers for individual genes or events showed higher variability between laboratories in one third of the cases, most possibly due to variability in the technical work, droplet size variability, and analysis of the raw data. GMO quantification with dPCR and qPCR was comparable. As methods originally designed for qPCR performed well in dPCR systems, already validated qPCR assays can most generally be used for dPCR technology with the purpose of GMO detection. Graphical abstract The output of three different PCR-based platforms was assessed in an inter-laboratory comparison.

  3. Inter-Population Variability of Endosymbiont Densities in the Asian Citrus Psyllid (Diaphorina citri Kuwayama).

    Science.gov (United States)

    Chu, Chia-Ching; Gill, Torrence A; Hoffmann, Mark; Pelz-Stelinski, Kirsten S

    2016-05-01

    The Asian citrus psyllid (Diaphorina citri Kuwayama) is an insect pest capable of transmitting Candidatus Liberibacter asiaticus (CLas), the causal agent of citrus greening in North America. D. citri also harbors three endosymbionts, Wolbachia, Candidatus Carsonella ruddii, and Candidatus Profftella armatura, which may influence D. citri physiology and fitness. Although genomic researches on these bacteria have been conducted, much remains unclear regarding their ecology and inter-population variability in D. citri. The present work examined the densities of each endosymbiont in adult D. citri sampled from different populations using quantitative PCR. Under field conditions, the densities of all three endosymbionts positively correlated with each other, and they are associated with D. citri gender and locality. In addition, the infection density of CLas also varied across populations. Although an analysis pooling D. citri from different populations showed that CLas-infected individuals tended to have lower endosymbiont densities compared to uninfected individuals, the difference was not significant when the population was included as a factor in the analysis, suggesting that other population-specific factors may have stronger effects on endosymbiont densities. To determine whether there is a genetic basis to the density differences, endosymbiont densities between aged CLas-negative females of two D. citri populations reared under standardized laboratory conditions were compared. Results suggested that inter-population variability in Wolbachia infection density is associated with the genotypes of the endosymbiont or the host. Findings from this work could facilitate understanding of D. citri-bacterial associations that may benefit the development of approaches for managing citrus greening, such as prevention of CLas transmission.

  4. Inter- and intra-population genetic variability of introduced silkworm (Bombyx mori L.) strains raised in Bulgaria

    OpenAIRE

    Teodora Staykova

    2013-01-01

    The genetic variability of four populations belonging to two introduced silkworm strains (Bombyx mori L.) of various origins has been studied using isoenzymic analysis of six enzyme systems. Nonspecific esterases, phosphoglucomutase, malate dehydrogenase, acid phosphatase, alkaline phosphatase and hexokinase from different tissue of larvae 5th instar have been analysed using PAGE. Polymorphism in six from a total of nine loci has been found. Inter- and intra-population differences have been a...

  5. Inter- and intrascanner variability of pulmonary nodule volumetry on low-dose 64-row CT: an anthropomorphic phantom study

    Science.gov (United States)

    Xie, X; Willemink, M J; Zhao, Y; de Jong, P A; van Ooijen, P M A; Oudkerk, M; Greuter, M J W

    2013-01-01

    Objective: To assess inter- and intrascanner variability in volumetry of solid pulmonary nodules in an anthropomorphic thoracic phantom using low-dose CT. Methods: Five spherical solid artificial nodules [diameters 3, 5, 8, 10 and 12 mm; CT density +100 Hounsfield units (HU)] were randomly placed inside an anthropomorphic thoracic phantom in different combinations. The phantom was examined on two 64-row multidetector CT (64-MDCT) systems (CT-A and CT-B) from different vendors with a low-dose protocol. Each CT examination was performed three times. The CT examinations were evaluated twice by independent blinded observers. Nodule volume was semi-automatically measured by dedicated software. Interscanner variability was evaluated by Bland–Altman analysis and expressed as 95% confidence interval (CI) of relative differences. Intrascanner variability was expressed as 95% CI of relative variation from the mean. Results: No significant difference in CT-derived volume was found between CT-A and CT-B, except for the 3-mm nodules (pvolumetry of artificial pulmonary nodules between 5 mm and 12 mm in diameter. Inter- and intrascanner variability decreases at a larger nodule size to a maximum of 4.9% for ≥8 mm nodules. Advances in knowledge: The commonly accepted cut-off of 25% to determine nodule growth has the potential to be reduced for ≥8 mm nodules. This offers the possibility of reducing the interval for repeated CT scans in lung cancer screenings. PMID:23884758

  6. Research reactor instrumentation and control technology. Report of a technical committee meeting

    International Nuclear Information System (INIS)

    1997-10-01

    The majority of research reactors operating today were put into operation 20 years ago, and some of them underwent modifications, upgrading and refurbishing since their construction to meet the requirements for higher neutron fluxes. However, a few of these ageing research reactors are still operating with their original instrumentation and control systems (I and C) which are important for reactor safety to guard against abnormal occurrences and reactor control involving startup, shutdown and power regulation. Worn and obsolete I and C systems cause operational problems as well as difficulties in obtaining replacement parts. In addition, satisfying the stringent safety conditions laid out by the nuclear regulatory bodies requires the modernization of research reactors I and C systems and integration of additional instrumentation units to the reactor. In order to clarify these issues and to provide some guidance to reactor operators on state-of-art technology and future trends for the I and C systems for research reactors, a Technical Committee Meeting on Technology and Trends for Research Reactor Instrumentation and Controls was held in Ljubljana, Slovenia, from 4 to 8 December 1995. This publication summarizes the discussions and recommendations resulting from that meeting. This is expected to benefit the research reactor operators planning I and C improvements. Refs, figs, tabs

  7. Instrumental variables estimation of exposure effects on a time-to-event endpoint using structural cumulative survival models.

    Science.gov (United States)

    Martinussen, Torben; Vansteelandt, Stijn; Tchetgen Tchetgen, Eric J; Zucker, David M

    2017-12-01

    The use of instrumental variables for estimating the effect of an exposure on an outcome is popular in econometrics, and increasingly so in epidemiology. This increasing popularity may be attributed to the natural occurrence of instrumental variables in observational studies that incorporate elements of randomization, either by design or by nature (e.g., random inheritance of genes). Instrumental variables estimation of exposure effects is well established for continuous outcomes and to some extent for binary outcomes. It is, however, largely lacking for time-to-event outcomes because of complications due to censoring and survivorship bias. In this article, we make a novel proposal under a class of structural cumulative survival models which parameterize time-varying effects of a point exposure directly on the scale of the survival function; these models are essentially equivalent with a semi-parametric variant of the instrumental variables additive hazards model. We propose a class of recursive instrumental variable estimators for these exposure effects, and derive their large sample properties along with inferential tools. We examine the performance of the proposed method in simulation studies and illustrate it in a Mendelian randomization study to evaluate the effect of diabetes on mortality using data from the Health and Retirement Study. We further use the proposed method to investigate potential benefit from breast cancer screening on subsequent breast cancer mortality based on the HIP-study. © 2017, The International Biometric Society.

  8. Important variables for parents' postnatal sense of security: evaluating a new Swedish instrument (the PPSS instrument).

    Science.gov (United States)

    Persson, Eva K; Dykes, Anna-Karin

    2009-08-01

    to evaluate dimensions of both parents' postnatal sense of security the first week after childbirth, and to determine associations between the PPSS instrument and different sociodemographic and situational background variables. evaluative, cross-sectional design. 113 mothers and 99 fathers with children live born at term, from five hospitals in southern Sweden. mothers and fathers had similar feelings concerning postnatal sense of security. Of the dimensions in the PPSS instrument, a sense of midwives'/nurses' empowering behaviour, a sense of one's own general well-being and a sense of the mother's well-being as experienced by the father were the most important dimensions for parents' experienced security. A sense of affinity within the family (for both parents) and a sense of manageable breast feeding (for mothers) were not significantly associated with their experienced security. A sense of participation during pregnancy and general anxiety were significantly associated background variables for postnatal sense of security for both parents. For the mothers, parity and a sense that the father was participating during pregnancy were also significantly associated. more focus on parents' participation during pregnancy as well as midwives'/nurses' empowering behaviour during the postnatal period will be beneficial for both parents' postnatal sense of security.

  9. In situ study of the impact of inter- and intra-reader variability on region of interest (ROI) analysis in preclinical molecular imaging.

    Science.gov (United States)

    Habte, Frezghi; Budhiraja, Shradha; Keren, Shay; Doyle, Timothy C; Levin, Craig S; Paik, David S

    2013-01-01

    We estimated reader-dependent variability of region of interest (ROI) analysis and evaluated its impact on preclinical quantitative molecular imaging. To estimate reader variability, we used five independent image datasets acquired each using microPET and multispectral fluorescence imaging (MSFI). We also selected ten experienced researchers who utilize molecular imaging in the same environment that they typically perform their own studies. Nine investigators blinded to the data type completed the ROI analysis by drawing ROIs manually that delineate the tumor regions to the best of their knowledge and repeated the measurements three times, non-consecutively. Extracted mean intensities of voxels within each ROI are used to compute the coefficient of variation (CV) and characterize the inter- and intra-reader variability. The impact of variability was assessed through random samples iterated from normal distributions for control and experimental groups on hypothesis testing and computing statistical power by varying subject size, measured difference between groups and CV. The results indicate that inter-reader variability was 22.5% for microPET and 72.2% for MSFI. Additionally, mean intra-reader variability was 10.1% for microPET and 26.4% for MSFI. Repeated statistical testing showed that a total variability of CV variability has been observed mainly due to differences in the ROI placement and geometry drawn between readers, which may adversely affect statistical power and erroneously lead to negative study outcomes.

  10. Practical methodological guide for hydrometric inter-laboratory organisation

    Science.gov (United States)

    Besson, David; Bertrand, Xavier

    2015-04-01

    Discharge measurements performed by the French governmental hydrometer team feed a national database. This data is available for general river flows knowkedge, flood forecasting, low water survey, statistical calculations flow, control flow regulatory and many other uses. Regularly checking the measurements quality and better quantifying its accuracy is therefore an absolute need. The practice of inter-laboratory comparison in hydrometry particularly developed during the last decade. Indeed, discharge measurement can not easily be linked to a standard. Therefore, on-site measurement accuracy control is very difficult. Inter-laboratory comparison is thus a practical solution to this issue. However, it needs some regulations in order to ease its practice and legitimize its results. To do so, the French government hydrometrics teams produced a practical methodological guide for hydrometric inter-laboratory organisation in destination of hydrometers community in view of ensure the harmonization of inter-laboratory comparison practices for different materials (ADCP, current meter on wadind rod or gauging van, tracer dilution, surface speed) and flow range (flood, low water). Ensure the results formalization and banking. The realisation of this practice guide is grounded on the experience of the governmental teams & their partners (or fellows), following existing approaches (Doppler group especially). The guide is designated to validate compliance measures and identify outliers : Hardware, methodological, environmental, or human. Inter-laboratory comparison provides the means to verify the compliance of the instruments (devices + methods + operators) and provides methods to determine an experimental uncertainty of the tested measurement method which is valid only for the site and the measurement conditions but does not address the calibration or periodic monitoring of the few materials. After some conceptual definitions, the guide describes the different stages of an

  11. Curriculum Management Practices in Pedagogical Coordinations of Araucania Schools: Unveiling Technical/Instrumental Rationality, Control and Power Mechanisms Underlying

    Directory of Open Access Journals (Sweden)

    Juan Carlos Beltrán-Véliz

    2016-01-01

    Full Text Available This article consists of a case study regarding curriculum management practices of pedagogical coordinators in schools in Araucania area. The study aims to reveal technical/instrumental rationality, control and power mechanisms that underlie the curriculum management practices of such pedagogical coordinators of schools in Araucania region. A descriptive qualitative design based on the constructionist grounded theory and the constant comparative method is considered. Subjects studied included 12 technical leaders and 22 teachers from Araucania schools. Techniques for collecting information were semi-structured interview and texts for reading. Four categories rose from axial coding. Findings reveal that the teaching process is reduced to an instructional process. Furthermore, there is no uniformity of criteria regarding general functions that must be met. In the same extent, activity coordination is centered on bureaucratic administrative aspects, with main focus on task control. Regulations, programs and educational projects are used as control mechanisms. In addition, absence of spaces for professional discussion of pedagogical work and for constructive criticism is envisioned. This study concludes that pedagogical coordination practices are geared from an “instrumental rationality”, anchored in technical management set up in control and power.

  12. Inter-seasonal variability in baseflow recession rates: The role of aquifer antecedent storage in central California watersheds

    Science.gov (United States)

    Bart, Ryan; Hope, Allen

    2014-11-01

    Baseflow recession rates vary inter-seasonally in many watersheds. This variability is generally associated with changes in evapotranspiration; however, an additional and less studied control over inter-seasonal baseflow recession rates is the effect of aquifer antecedent storage. Understanding the role of aquifer antecedent storage on baseflow recession rates is crucial for Mediterranean-climate regions, where seasonal asynchronicity of precipitation and energy levels produces large inter-seasonal differences in aquifer storage. The primary objective of this study was to elucidate the relation between aquifer antecedent storage and baseflow recession rates in four central California watersheds using antecedent streamflow as a surrogate for watershed storage. In addition, a parsimonious storage-discharge model consisting of two nonlinear stores in parallel was developed as a heuristic tool for interpreting the empirical results and providing insight into how inter-seasonal changes in aquifer antecedent storage may affect baseflow recession rates. Antecedent streamflow cumulated from the beginning of the wateryear was found to be the strongest predictor of baseflow recession rates, indicating that inter-seasonal differences in aquifer storage are a key control on baseflow recession rates in California watersheds. Baseflow recession rates and antecedent streamflow exhibited a negative power-law relation, with baseflow recession rates decreasing by up to two orders of magnitude as antecedent streamflow levels increased. Inference based on the storage-discharge model indicated that the dominant source of recession flow shifted from small, rapid response aquifers at the beginning of the wet season to large, seasonal aquifers as the wet season progressed. Aquifer antecedent storage in California watersheds should be accounted for along with evapotranspiration when characterizing baseflow recession rates.

  13. Inter-annual to multi-decadal variability in prairie water resources over the past millennium

    International Nuclear Information System (INIS)

    Sauchyn, D.

    2008-01-01

    In the Prairie Provinces, declining levels have been recently recorded for various rivers and lakes, and further reductions are projected. These trends reflect human impact in terms of increasing water consumption and possibly anthropogenic climate change. From the coupling of hydrological models and climate change scenarios, researchers have projected lower future summer flows as global warming brings shorter warmer winters and longer and generally drier summers to western Canada. However, the detection and interpretation of trends from gauge records and model outputs are constrained by the relatively short perspective of decades and the uncertainties associated with projecting climate change and its impacts on hydrological regimes. A longer perspective on inter-annual to multi-decadal variability in water resources is available from moisture-sensitive tree-ring chronologies. We have established a dense network of low elevation chronologies spanning the headwaters of the Saskatchewan, Missouri, Churchill and Mackenzie River basins. Standardized tree-ring width for a large sample of trees and sites is a strong regional signal of annual and seasonal hydroclimate, and an especially good proxy of low water levels. Proxy streamflow records, up to 800 years in length, show quasi-periodic variability at inter-annual to multi-decadal scales that correspond to the tempo of sea-surface temperature anomalies. The industrial sponsors of our research, Manitoba Hydro and EPCOR, anticipate the use of our tree-ring reconstructions for informing forecasts of future water supplies and planning adaptation to climate change. Engineers from these companies, and more than 50 other water managers and planners from the Prairie Provinces, attended a workshop in March 2008 to explore potential applications of paleo-hydrological records to water resource management. (author)

  14. Technical descriptions of ten irrigation technologies for conserving energy

    Energy Technology Data Exchange (ETDEWEB)

    Harrer, B.J.; Wilfert, G.L.

    1983-05-01

    Technical description of ten technologies which were researched to save energy in irrigated agriculture are presented. These technologies are: well design and development ground water supply system optimization, column and pump redesign, variable-speed pumping, pipe network optimization, reduced-pressure center-pivot systems, low-energy precision application, automated gated-pipe system, computerized irrigation scheduling, and instrumented irrigation scheduling. (MHR)

  15. A selective review of the first 20 years of instrumental variables models in health-services research and medicine.

    Science.gov (United States)

    Cawley, John

    2015-01-01

    The method of instrumental variables (IV) is useful for estimating causal effects. Intuitively, it exploits exogenous variation in the treatment, sometimes called natural experiments or instruments. This study reviews the literature in health-services research and medical research that applies the method of instrumental variables, documents trends in its use, and offers examples of various types of instruments. A literature search of the PubMed and EconLit research databases for English-language journal articles published after 1990 yielded a total of 522 original research articles. Citations counts for each article were derived from the Web of Science. A selective review was conducted, with articles prioritized based on number of citations, validity and power of the instrument, and type of instrument. The average annual number of papers in health services research and medical research that apply the method of instrumental variables rose from 1.2 in 1991-1995 to 41.8 in 2006-2010. Commonly-used instruments (natural experiments) in health and medicine are relative distance to a medical care provider offering the treatment and the medical care provider's historic tendency to administer the treatment. Less common but still noteworthy instruments include randomization of treatment for reasons other than research, randomized encouragement to undertake the treatment, day of week of admission as an instrument for waiting time for surgery, and genes as an instrument for whether the respondent has a heritable condition. The use of the method of IV has increased dramatically in the past 20 years, and a wide range of instruments have been used. Applications of the method of IV have in several cases upended conventional wisdom that was based on correlations and led to important insights about health and healthcare. Future research should pursue new applications of existing instruments and search for new instruments that are powerful and valid.

  16. The contextual effects of social capital on health: a cross-national instrumental variable analysis.

    Science.gov (United States)

    Kim, Daniel; Baum, Christopher F; Ganz, Michael L; Subramanian, S V; Kawachi, Ichiro

    2011-12-01

    Past research on the associations between area-level/contextual social capital and health has produced conflicting evidence. However, interpreting this rapidly growing literature is difficult because estimates using conventional regression are prone to major sources of bias including residual confounding and reverse causation. Instrumental variable (IV) analysis can reduce such bias. Using data on up to 167,344 adults in 64 nations in the European and World Values Surveys and applying IV and ordinary least squares (OLS) regression, we estimated the contextual effects of country-level social trust on individual self-rated health. We further explored whether these associations varied by gender and individual levels of trust. Using OLS regression, we found higher average country-level trust to be associated with better self-rated health in both women and men. Instrumental variable analysis yielded qualitatively similar results, although the estimates were more than double in size in both sexes when country population density and corruption were used as instruments. The estimated health effects of raising the percentage of a country's population that trusts others by 10 percentage points were at least as large as the estimated health effects of an individual developing trust in others. These findings were robust to alternative model specifications and instruments. Conventional regression and to a lesser extent IV analysis suggested that these associations are more salient in women and in women reporting social trust. In a large cross-national study, our findings, including those using instrumental variables, support the presence of beneficial effects of higher country-level trust on self-rated health. Previous findings for contextual social capital using traditional regression may have underestimated the true associations. Given the close linkages between self-rated health and all-cause mortality, the public health gains from raising social capital within and across

  17. SU-F-J-103: Assessment of Liver Tumor Contrast for Radiation Therapy: Inter-Patient and Inter-Sequence Variability

    Energy Technology Data Exchange (ETDEWEB)

    Moore, B [Duke University Medical Physics Graduate Program, Durham, NC (United States); Yin, F; Cai, J [Duke University Medical Physics Graduate Program, Durham, NC (United States); Duke University Medical Center, Radiation Oncology, Durham, NC (United States); Czito, B; Palta, M [Duke University Medical Center, Radiation Oncology, Durham, NC (United States)

    2016-06-15

    Purpose: To determine the variation in tumor contrast between different MRI sequences and between patients for the purpose of MRI-based treatment planning. Methods: Multiple MRI scans of 11 patients with cancer(s) in the liver were included in this IRB-approved study. Imaging sequences consisted of T1W MRI, Contrast-Enhanced T1W MRI, T2W MRI, and T2*/T1W MRI. MRI images were acquired on a 1.5T GE Signa scanner with a four-channel torso coil. We calculated the tumor-to-tissue contrast to noise ratio (CNR) for each MR sequence by contouring the tumor and a region of interest (ROI) in a homogeneous region of the liver using the Eclipse treatment planning software. CNR was calculated (I-Tum-I-ROI)/SD-ROI, where I-Tum and I-ROI are the mean values of the tumor and the ROI respectively, and SD-ROI is the standard deviation of the ROI. The same tumor and ROI structures were used in all measurements for different MR sequences. Inter-patient Coefficient of variation (CV), and inter-sequence CV was determined. In addition, mean and standard deviation of CNR were calculated and compared between different MR sequences. Results: Our preliminary results showed large inter-patient CV (range: 37.7% to 88%) and inter-sequence CV (range 5.3% to 104.9%) of liver tumor CNR, indicating great variations in tumor CNR between MR sequences and between patients. Tumor CNR was found to be largest in CE-T1W (8.5±7.5), followed by T2W (4.2±2.4), T1W (3.4±2.2), and T2*/T1W (1.7±0.6) MR scans. The inter-patient CV of tumor CNR was also the largest in CE-T1W (88%), followed by T1W (64.3%), T1W (56.2%), and T2*/T1W (37.7) MR scans. Conclusion: Large inter-sequence and inter-patient variations were observed in liver tumor CNR. CE-T1W MR images on average provided the best tumor CNR. Efforts are needed to optimize tumor contrast and its consistency for MRI-based treatment planning of cancer in the liver. This project is supported by NIH grant: 1R21CA165384.

  18. SU-F-J-103: Assessment of Liver Tumor Contrast for Radiation Therapy: Inter-Patient and Inter-Sequence Variability

    International Nuclear Information System (INIS)

    Moore, B; Yin, F; Cai, J; Czito, B; Palta, M

    2016-01-01

    Purpose: To determine the variation in tumor contrast between different MRI sequences and between patients for the purpose of MRI-based treatment planning. Methods: Multiple MRI scans of 11 patients with cancer(s) in the liver were included in this IRB-approved study. Imaging sequences consisted of T1W MRI, Contrast-Enhanced T1W MRI, T2W MRI, and T2*/T1W MRI. MRI images were acquired on a 1.5T GE Signa scanner with a four-channel torso coil. We calculated the tumor-to-tissue contrast to noise ratio (CNR) for each MR sequence by contouring the tumor and a region of interest (ROI) in a homogeneous region of the liver using the Eclipse treatment planning software. CNR was calculated (I_Tum-I_ROI)/SD_ROI, where I_Tum and I_ROI are the mean values of the tumor and the ROI respectively, and SD_ROI is the standard deviation of the ROI. The same tumor and ROI structures were used in all measurements for different MR sequences. Inter-patient Coefficient of variation (CV), and inter-sequence CV was determined. In addition, mean and standard deviation of CNR were calculated and compared between different MR sequences. Results: Our preliminary results showed large inter-patient CV (range: 37.7% to 88%) and inter-sequence CV (range 5.3% to 104.9%) of liver tumor CNR, indicating great variations in tumor CNR between MR sequences and between patients. Tumor CNR was found to be largest in CE-T1W (8.5±7.5), followed by T2W (4.2±2.4), T1W (3.4±2.2), and T2*/T1W (1.7±0.6) MR scans. The inter-patient CV of tumor CNR was also the largest in CE-T1W (88%), followed by T1W (64.3%), T1W (56.2%), and T2*/T1W (37.7) MR scans. Conclusion: Large inter-sequence and inter-patient variations were observed in liver tumor CNR. CE-T1W MR images on average provided the best tumor CNR. Efforts are needed to optimize tumor contrast and its consistency for MRI-based treatment planning of cancer in the liver. This project is supported by NIH grant: 1R21CA165384

  19. Inter- and intra-observer variability in the assessment of atelectasis and consolidation in neonatal chest radiographs

    International Nuclear Information System (INIS)

    Bloomfield, F.H.; Teele, R.L.; Voss, M.; Knight, D.B.; Harding, J.E.

    1999-01-01

    Background. Radiology is an essential part of neonatal intensive care. Interpretation of chest radiographs frequently contributes to respiratory management of neonates, but there has been little assessment of the consistency of this interpretation. Objective. To assess the inter- and intra-observer variability for the reporting of atelectasis and/or consolidation in neonatal chest radiographs. Materials and methods. A total of 585 chest radiographs from the 220 babies ventilated in our nursery over a 2-year period were coded by two radiologists for generalised, lobar and segmental atelectasis and/or consolidation. Two months later one of the radiologists re-coded a random sample of these films (n = 117, 20 %). Agreement was assessed by the kappa statistic and by proportions of agreement for normality and abnormality. Results. The reported incidence of focal atelectasis was low (5-6 %). Focal changes of any nature were found in 21-26 % of films. Inter-observer agreement was fair to moderate (kappa = 0.25-0.44). Intra-observer agreement was mostly moderate to good (kappa = 0.38-0.66). Conclusion. The poor inter-observer agreement for the diagnosis of pulmonary parenchymal abnormalities on chest radiographs of neonates receiving intensive care suggests that abnormalities should be described rather than diagnoses given or that a list of differential diagnoses be offered. When research involves radiographic interpretation, the potential lack of consistency in reporting abnormalities must be borne in mind. (orig.)

  20. Inter- and intrareader variability in the interpretation of two radiographic classification systems for juvenile rheumatoid arthritis

    International Nuclear Information System (INIS)

    Doria, Andrea S.; Castro, Claudio C. de; Sernik, Renato A.; Vitule, Luis F.; Arantes, Paula R.; Lucato, Leandro; Germano, Marco A.N.; Cerri, Giovanni G.; Kiss, Maria Helena B.; Silva, Carlos H.M.; Zerbini, Cristiano A.F.

    2003-01-01

    To evaluate the inter- and intrareader variability for interpretation of a modified Larsen's radiographic classification system for juvenile rheumatoid arthritis (JRA) focused on osteochondral lesions and a conventional Larsen's classification system, compared to a reference MR scoring system of corresponding images. Seventy-five radiographs of 60 children with JRA, performed within a short interval of time from the MR examinations, were independently evaluated by three experienced radiologists, three diagnostic imaging residents and three rheumatologists, in two separate sessions, according to the two different classification methods, blinded to the corresponding MR images. The inter- and intrareader concordance rates between the two radiographic classification systems and the MR-related radiographs were respectively poor and poor/moderate. The interobserver range of weighted kappa values for the conventional and the modified Larsen's system respectively was 0.25-0.37 vs 0.19-0.39 for radiologists, 0.25-0.37 vs 0.18-0.30 for residents and 0.19-0.51 vs 0.17-0.29 for rheumatologists. The intrareader rate ranged from 0.17-0.55 for radiologists, 0.2-0.56 for residents, and 0.14-0.59 for rheumatologists. Although the proposal of a new radiographic classification system for JRA focused on osteochondral abnormalities sounds promising, the low inter- and intrareader concordance rates with an MR-related radiographic system makes the clinical applicability of such a radiographic system less suitable. (orig.)

  1. Inter-decadal change in potential predictability of the East Asian summer monsoon

    Science.gov (United States)

    Li, Jiao; Ding, Ruiqiang; Wu, Zhiwei; Zhong, Quanjia; Li, Baosheng; Li, Jianping

    2018-05-01

    The significant inter-decadal change in potential predictability of the East Asian summer monsoon (EASM) has been investigated using the signal-to-noise ratio method. The relatively low potential predictability appears from the early 1950s through the late 1970s and during the early 2000s, whereas the potential predictability is relatively high from the early 1980s through the late 1990s. The inter-decadal change in potential predictability of the EASM can be attributed mainly to variations in the external signal of the EASM. The latter is mostly caused by the El Niño-Southern Oscillation (ENSO) inter-decadal variability. As a major external signal of the EASM, the ENSO inter-decadal variability experiences phase transitions from negative to positive phases in the late 1970s, and to negative phases in the late 1990s. Additionally, ENSO is generally strong (weak) during a positive (negative) phase of the ENSO inter-decadal variability. The strong ENSO is expected to have a greater influence on the EASM, and vice versa. As a result, the potential predictability of the EASM tends to be high (low) during a positive (negative) phase of the ENSO inter-decadal variability. Furthermore, a suite of Pacific Pacemaker experiments suggests that the ENSO inter-decadal variability may be a key pacemaker of the inter-decadal change in potential predictability of the EASM.

  2. Radioisotope instruments

    CERN Document Server

    Cameron, J F; Silverleaf, D J

    1971-01-01

    International Series of Monographs in Nuclear Energy, Volume 107: Radioisotope Instruments, Part 1 focuses on the design and applications of instruments based on the radiation released by radioactive substances. The book first offers information on the physical basis of radioisotope instruments; technical and economic advantages of radioisotope instruments; and radiation hazard. The manuscript then discusses commercial radioisotope instruments, including radiation sources and detectors, computing and control units, and measuring heads. The text describes the applications of radioisotop

  3. Work and Inter-subjectivity: a theoretical reflection on its dialectics in the field of health and nursing.

    Science.gov (United States)

    Carvalho, Brígida Gimenez; Peduzzi, Marina; Mandú, Edir Nei Teixeira; Ayres, José Ricardo de Carvalho Mesquita

    2012-01-01

    This theoretical reflection intends to show the inter-subjective relationship that takes place in health and nursing practices under the following theoretical perspectives: Institutional Analysis, Psychodynamics of Labor and the Theory of Communicative Action, with an emphasis on the latter. Linking these concepts to the Marxist approach to work in the field of health emerges from recognizing the need for its continuous reconstruction-in this case, with a view to understand the interaction and communication intrinsic to work in action. The theory of Communicative Action seeks to consider these two inextricable dimensions: work as productive action and as interaction. The first corresponds to instrumental action based on technical rules with a production-guided rationale. The second refers to the interaction that takes place as communicative action and seeks understanding among subjects. We assume that adopting this theoretical perspective in the analysis of health and nursing practices opens new possibilities for clarifying its social and historical process and inter-subjective connections.

  4. Invited Commentary: Using Financial Credits as Instrumental Variables for Estimating the Causal Relationship Between Income and Health.

    Science.gov (United States)

    Pega, Frank

    2016-05-01

    Social epidemiologists are interested in determining the causal relationship between income and health. Natural experiments in which individuals or groups receive income randomly or quasi-randomly from financial credits (e.g., tax credits or cash transfers) are increasingly being analyzed using instrumental variable analysis. For example, in this issue of the Journal, Hamad and Rehkopf (Am J Epidemiol. 2016;183(9):775-784) used an in-work tax credit called the Earned Income Tax Credit as an instrument to estimate the association between income and child development. However, under certain conditions, the use of financial credits as instruments could violate 2 key instrumental variable analytic assumptions. First, some financial credits may directly influence health, for example, through increasing a psychological sense of welfare security. Second, financial credits and health may have several unmeasured common causes, such as politics, other social policies, and the motivation to maximize the credit. If epidemiologists pursue such instrumental variable analyses, using the amount of an unconditional, universal credit that an individual or group has received as the instrument may produce the most conceptually convincing and generalizable evidence. However, other natural income experiments (e.g., lottery winnings) and other methods that allow better adjustment for confounding might be more promising approaches for estimating the causal relationship between income and health. © The Author 2016. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  5. Assessing inter- and intra-individual cognitive variability in patients at risk for cognitive impairment: the case of minimal hepatic encephalopathy.

    Science.gov (United States)

    Bisiacchi, Patrizia; Cona, Giorgia; Tarantino, Vincenza; Schiff, Sami; Montagnese, Sara; Amodio, Piero; Capizzi, Giovanna

    2014-12-01

    Recent evidence reveals that inter- and intra-individual variability significantly affects cognitive performance in a number of neuropsychological pathologies. We applied a flexible family of statistical models to elucidate the contribution of inter- and intra-individual variables on cognitive functioning in healthy volunteers and patients at risk for hepatic encephalopathy (HE). Sixty-five volunteers (32 patients with cirrhosis and 33 healthy volunteers) were assessed by means of the Inhibitory Control Task (ICT). A Generalized Additive Model for Location, Scale and Shape (GAMLSS) was fitted for jointly modeling the mean and the intra-variability of Reaction Times (RTs) as a function of socio-demographic and task related covariates. Furthermore, a Generalized Linear Mixed Model (GLMM) was fitted for modeling accuracy. When controlling for the covariates, patients without minimal hepatic encephalopathy (MHE) did not differ from patients with MHE in the low-demanding condition, both in terms of RTs and accuracy. Moreover, they showed a significant decline in accuracy compared to the control group. Compared to patients with MHE, patients without MHE showed faster RTs and higher accuracy only in the high-demanding condition. The results revealed that the application of GAMLSS and GLMM models are able to capture subtle cognitive alterations, previously not detected, in patients' subclinical pathologies.

  6. Intra-Rater, Inter-Rater and Test-Retest Reliability of an Instrumented Timed Up and Go (iTUG Test in Patients with Parkinson's Disease.

    Directory of Open Access Journals (Sweden)

    Rob C van Lummel

    Full Text Available The "Timed Up and Go" (TUG is a widely used measure of physical functioning in older people and in neurological populations, including Parkinson's Disease. When using an inertial sensor measurement system (instrumented TUG [iTUG], the individual components of the iTUG and the trunk kinematics can be measured separately, which may provide relevant additional information.The aim of this study was to determine intra-rater, inter-rater and test-retest reliability of the iTUG in patients with Parkinson's Disease.Twenty eight PD patients, aged 50 years or older, were included. For the iTUG the DynaPort Hybrid (McRoberts, The Hague, The Netherlands was worn at the lower back. The device measured acceleration and angular velocity in three directions at a rate of 100 samples/s. Patients performed the iTUG five times on two consecutive days. Repeated measurements by the same rater on the same day were used to calculate intra-rater reliability. Repeated measurements by different raters on the same day were used to calculate intra-rater and inter-rater reliability. Repeated measurements by the same rater on different days were used to calculate test-retest reliability.Nineteen ICC values (15% were ≥ 0.9 which is considered as excellent reliability. Sixty four ICC values (49% were ≥ 0.70 and < 0.90 which is considered as good reliability. Thirty one ICC values (24% were ≥ 0.50 and < 0.70, indicating moderate reliability. Sixteen ICC values (12% were ≥ 0.30 and < 0.50 indicating poor reliability. Two ICT values (2% were < 0.30 indicating very poor reliability.In conclusion, in patients with Parkinson's disease the intra-rater, inter-rater, and test-retest reliability of the individual components of the instrumented TUG (iTUG was excellent to good for total duration and for turning durations, and good to low for the sub durations and for the kinematics of the SiSt and StSi. The results of this fully automated analysis of instrumented TUG movements

  7. Technical clarity in inter-agency negotiations: Lessons from four hydropower projects

    Science.gov (United States)

    Burkardt, Nina; Lamb, Berton Lee; Taylor, Jonathan G.; Waddle, Terry J.

    1995-01-01

    We investigated the effect of technical clarity on success in multi-party negotiations in the Federal Energy Regulatory Commission (FERC) licensing process. Technical clarity is the shared understanding of dimensions such as the geographic extent of the project, range of flows to be considered, important species and life stages, and variety of water uses considered. The results of four hydropower licensing consultations are reported. Key participants were interviewed to ascertain the level of technical clarity present during the consultations and the degree to which the consultations were successful. Technical clarity appears to be a prerequisite for successful outcomes. Factors that enhance technical clarity include simple project design, new rather than existing projects, precise definition of issues, a sense of urgency to reach agreement, a sense of fairness among participants, and consistency in participation. Negotiators should not neglect the critical pre-negotiation steps of defining technical issues and determining appropriate studies, deciding how to interpret studies, and agreeing on responses to study results.

  8. Exploring intra- and inter-reader variability in uni-dimensional, bi-dimensional, and volumetric measurements of solid tumors on CT scans reconstructed at different slice intervals

    International Nuclear Information System (INIS)

    Zhao, Binsheng; Tan, Yongqiang; Bell, Daniel J.; Marley, Sarah E.; Guo, Pingzhen; Mann, Helen; Scott, Marietta L.J.; Schwartz, Lawrence H.; Ghiorghiu, Dana C.

    2013-01-01

    Objective: Understanding magnitudes of variability when measuring tumor size may be valuable in improving detection of tumor change and thus evaluating tumor response to therapy in clinical trials and care. Our study explored intra- and inter-reader variability of tumor uni-dimensional (1D), bi-dimensional (2D), and volumetric (VOL) measurements using manual and computer-aided methods (CAM) on CT scans reconstructed at different slice intervals. Materials and methods: Raw CT data from 30 patients enrolled in oncology clinical trials was reconstructed at 5, 2.5, and 1.25 mm slice intervals. 118 lesions in the lungs, liver, and lymph nodes were analyzed. For each lesion, two independent radiologists manually and, separately, using computer software, measured the maximum diameter (1D), maximum perpendicular diameter, and volume (CAM only). One of them blindly repeated the measurements. Intra- and inter-reader variability for the manual method and CAM were analyzed using linear mixed-effects models and Bland–Altman method. Results: For the three slice intervals, the maximum coefficients of variation for manual intra-/inter-reader variability were 6.9%/9.0% (1D) and 12.3%/18.0% (2D), and for CAM were 5.4%/9.3% (1D), 11.3%/18.8% (2D) and 9.3%/18.0% (VOL). Maximal 95% reference ranges for the percentage difference in intra-reader measurements for manual 1D and 2D, and CAM VOL were (−15.5%, 25.8%), (−27.1%, 51.6%), and (−22.3%, 33.6%), respectively. Conclusions: Variability in measuring the diameter and volume of solid tumors, manually and by CAM, is affected by CT slice interval. The 2.5 mm slice interval provides the least measurement variability. Among the three techniques, 2D has the greatest measurement variability compared to 1D and 3D

  9. Inter annual variability of the global carbon cycle (1992-2005) inferred by inversion of atmospheric CO2 and δ13CO2 measurements

    International Nuclear Information System (INIS)

    Rayner, P.J.; Pickett-Heaps, C.; Law, R.M.; Allison, C.E.; Francey, R.J.; Trudinger, C.M.

    2008-01-01

    We present estimates of the surface sources and sinks of CO 2 for 1992 - 2005 deduced from atmospheric inversions. We use atmospheric CO 2 records from 67 sites and 10 δ 13 CO 2 records. We use two atmospheric models to increase the robustness of the results. The results suggest that inter annual variability is dominated by the tropical land. Statistically significant variability in the tropical Pacific supports recent ocean modeling studies in that region. The northern land also shows significant variability. In particular, there is a large positive anomaly in 2003 in north Asia, which we associate with anomalous biomass burning. Results using δ 13 CO 2 and CO 2 are statistically consistent with those using only CO 2 , suggesting that it is valid to use both types of data together. An objective analysis of residuals suggests that our treatment of uncertainties in CO 2 is conservative, while those for δ 13 CO 2 are optimistic, highlighting problems in our simple isotope model. Finally, δ 13 CO 2 measurements offer a good constraint to nearby land regions, suggesting an ongoing value in these measurements for studies of inter annual variability. (authors)

  10. Inter-rater reliability of measures to characterize the tobacco retail environment in Mexico

    Directory of Open Access Journals (Sweden)

    Marissa G Hall

    2015-11-01

    Full Text Available Objective. To evaluate the inter-rater reliability of a data collection instrument to assess the tobacco retail environ- ment in Mexico, after major marketing regulations were implemented. Materials and methods. In 2013, two data collectors independently evaluated 21 stores in two census tracts, through a data collection instrument that assessed the presence of price promotions, whether single cigarettes were sold, the number of visible advertisements, the pre- sence of signage prohibiting the sale of cigarettes to minors, and characteristics of cigarette pack displays. We evaluated the inter-rater reliability of the collected data, through the calculation of metrics such as intraclass correlation coefficient, percent agreement, Cohen’s kappa and Krippendorff’s alpha. Results. Most measures demonstrated substantial or perfect inter-rater reliability. Conclusions. Our results indicate the potential utility of the data collection instrument for future point-of-sale research.

  11. Assessing variability in chemical acute toxicity of unionid mussels: Influence of intra- and inter-laboratory testing, life stage, and species - SETAC Abstract

    Science.gov (United States)

    We developed a toxicity database for unionid mussels to examine the extent of intra- and inter-laboratory variability in acute toxicity tests with mussel larvae (glochidia) and juveniles; the extent of differential sensitivity of the two life stages; and the variation in sensitiv...

  12. Time dependent analysis of assay comparability: a novel approach to understand intra- and inter-site variability over time

    Science.gov (United States)

    Winiwarter, Susanne; Middleton, Brian; Jones, Barry; Courtney, Paul; Lindmark, Bo; Page, Ken M.; Clark, Alan; Landqvist, Claire

    2015-09-01

    We demonstrate here a novel use of statistical tools to study intra- and inter-site assay variability of five early drug metabolism and pharmacokinetics in vitro assays over time. Firstly, a tool for process control is presented. It shows the overall assay variability but allows also the following of changes due to assay adjustments and can additionally highlight other, potentially unexpected variations. Secondly, we define the minimum discriminatory difference/ratio to support projects to understand how experimental values measured at different sites at a given time can be compared. Such discriminatory values are calculated for 3 month periods and followed over time for each assay. Again assay modifications, especially assay harmonization efforts, can be noted. Both the process control tool and the variability estimates are based on the results of control compounds tested every time an assay is run. Variability estimates for a limited set of project compounds were computed as well and found to be comparable. This analysis reinforces the need to consider assay variability in decision making, compound ranking and in silico modeling.

  13. LARF: Instrumental Variable Estimation of Causal Effects through Local Average Response Functions

    Directory of Open Access Journals (Sweden)

    Weihua An

    2016-07-01

    Full Text Available LARF is an R package that provides instrumental variable estimation of treatment effects when both the endogenous treatment and its instrument (i.e., the treatment inducement are binary. The method (Abadie 2003 involves two steps. First, pseudo-weights are constructed from the probability of receiving the treatment inducement. By default LARF estimates the probability by a probit regression. It also provides semiparametric power series estimation of the probability and allows users to employ other external methods to estimate the probability. Second, the pseudo-weights are used to estimate the local average response function conditional on treatment and covariates. LARF provides both least squares and maximum likelihood estimates of the conditional treatment effects.

  14. The productivity of mental health care: an instrumental variable approach.

    Science.gov (United States)

    Lu, Mingshan

    1999-06-01

    BACKGROUND: Like many other medical technologies and treatments, there is a lack of reliable evidence on treatment effectiveness of mental health care. Increasingly, data from non-experimental settings are being used to study the effect of treatment. However, as in a number of studies using non-experimental data, a simple regression of outcome on treatment shows a puzzling negative and significant impact of mental health care on the improvement of mental health status, even after including a large number of potential control variables. The central problem in interpreting evidence from real-world or non-experimental settings is, therefore, the potential "selection bias" problem in observational data set. In other words, the choice/quantity of mental health care may be correlated with other variables, particularly unobserved variables, that influence outcome and this may lead to a bias in the estimate of the effect of care in conventional models. AIMS OF THE STUDY: This paper addresses the issue of estimating treatment effects using an observational data set. The information in a mental health data set obtained from two waves of data in Puerto Rico is explored. The results using conventional models - in which the potential selection bias is not controlled - and that from instrumental variable (IV) models - which is what was proposed in this study to correct for the contaminated estimation from conventional models - are compared. METHODS: Treatment effectiveness is estimated in a production function framework. Effectiveness is measured as the improvement in mental health status. To control for the potential selection bias problem, IV approaches are employed. The essence of the IV method is to use one or more instruments, which are observable factors that influence treatment but do not directly affect patient outcomes, to isolate the effect of treatment variation that is independent of unobserved patient characteristics. The data used in this study are the first (1992

  15. Fasting Glucose and the Risk of Depressive Symptoms: Instrumental-Variable Regression in the Cardiovascular Risk in Young Finns Study.

    Science.gov (United States)

    Wesołowska, Karolina; Elovainio, Marko; Hintsa, Taina; Jokela, Markus; Pulkki-Råback, Laura; Pitkänen, Niina; Lipsanen, Jari; Tukiainen, Janne; Lyytikäinen, Leo-Pekka; Lehtimäki, Terho; Juonala, Markus; Raitakari, Olli; Keltikangas-Järvinen, Liisa

    2017-12-01

    Type 2 diabetes (T2D) has been associated with depressive symptoms, but the causal direction of this association and the underlying mechanisms, such as increased glucose levels, remain unclear. We used instrumental-variable regression with a genetic instrument (Mendelian randomization) to examine a causal role of increased glucose concentrations in the development of depressive symptoms. Data were from the population-based Cardiovascular Risk in Young Finns Study (n = 1217). Depressive symptoms were assessed in 2012 using a modified Beck Depression Inventory (BDI-I). Fasting glucose was measured concurrently with depressive symptoms. A genetic risk score for fasting glucose (with 35 single nucleotide polymorphisms) was used as an instrumental variable for glucose. Glucose was not associated with depressive symptoms in the standard linear regression (B = -0.04, 95% CI [-0.12, 0.04], p = .34), but the instrumental-variable regression showed an inverse association between glucose and depressive symptoms (B = -0.43, 95% CI [-0.79, -0.07], p = .020). The difference between the estimates of standard linear regression and instrumental-variable regression was significant (p = .026) CONCLUSION: Our results suggest that the association between T2D and depressive symptoms is unlikely to be caused by increased glucose concentrations. It seems possible that T2D might be linked to depressive symptoms due to low glucose levels.

  16. Instrument Variables for Reducing Noise in Parallel MRI Reconstruction

    Directory of Open Access Journals (Sweden)

    Yuchou Chang

    2017-01-01

    Full Text Available Generalized autocalibrating partially parallel acquisition (GRAPPA has been a widely used parallel MRI technique. However, noise deteriorates the reconstructed image when reduction factor increases or even at low reduction factor for some noisy datasets. Noise, initially generated from scanner, propagates noise-related errors during fitting and interpolation procedures of GRAPPA to distort the final reconstructed image quality. The basic idea we proposed to improve GRAPPA is to remove noise from a system identification perspective. In this paper, we first analyze the GRAPPA noise problem from a noisy input-output system perspective; then, a new framework based on errors-in-variables (EIV model is developed for analyzing noise generation mechanism in GRAPPA and designing a concrete method—instrument variables (IV GRAPPA to remove noise. The proposed EIV framework provides possibilities that noiseless GRAPPA reconstruction could be achieved by existing methods that solve EIV problem other than IV method. Experimental results show that the proposed reconstruction algorithm can better remove the noise compared to the conventional GRAPPA, as validated with both of phantom and in vivo brain data.

  17. Inter- and Intra-Observer Variability in Prostate Definition With Tissue Harmonic and Brightness Mode Imaging

    International Nuclear Information System (INIS)

    Sandhu, Gurpreet Kaur; Dunscombe, Peter; Meyer, Tyler; Pavamani, Simon; Khan, Rao

    2012-01-01

    Purpose: The objective of this study was to compare the relative utility of tissue harmonic (H) and brightness (B) transrectal ultrasound (TRUS) images of the prostate by studying interobserver and intraobserver variation in prostate delineation. Methods and Materials: Ten patients with early-stage disease were randomly selected. TRUS images of prostates were acquired using B and H modes. The prostates on all images were contoured by an experienced radiation oncologist (RO) and five equally trained observers. The observers were blinded to information regarding patient and imaging mode. The volumes of prostate glands and areas of midgland slices were calculated. Volumes contoured were compared among the observers and between observer group and RO. Contours on one patient were repeated five times by four observers to evaluate the intraobserver variability. Results: A one-sample Student t-test showed the volumes outlined by five observers are in agreement (p > 0.05) with the RO. Paired Student t-test showed prostate volumes (p = 0.008) and midgland areas (p = 0.006) with H mode were significantly smaller than that with B mode. Two-factor analysis of variances showed significant interobserver variability (p < 0.001) in prostate volumes and areas. Inter- and intraobserver consistency was quantified as the standard deviation of mean volumes and areas, and concordance indices. It was found that for small glands (≤35 cc) H mode provided greater interobserver consistency; however, for large glands (≥35 cc), B mode provided more consistent estimates. Conclusions: H mode provided superior inter- and intraobserver agreement in prostate volume definition for small to medium prostates. In large glands, H mode does not exhibit any additional advantage. Although harmonic imaging has not proven advantageous for all cases, its utilization seems to be judicious for small prostates.

  18. Robust best linear estimation for regression analysis using surrogate and instrumental variables.

    Science.gov (United States)

    Wang, C Y

    2012-04-01

    We investigate methods for regression analysis when covariates are measured with errors. In a subset of the whole cohort, a surrogate variable is available for the true unobserved exposure variable. The surrogate variable satisfies the classical measurement error model, but it may not have repeated measurements. In addition to the surrogate variables that are available among the subjects in the calibration sample, we assume that there is an instrumental variable (IV) that is available for all study subjects. An IV is correlated with the unobserved true exposure variable and hence can be useful in the estimation of the regression coefficients. We propose a robust best linear estimator that uses all the available data, which is the most efficient among a class of consistent estimators. The proposed estimator is shown to be consistent and asymptotically normal under very weak distributional assumptions. For Poisson or linear regression, the proposed estimator is consistent even if the measurement error from the surrogate or IV is heteroscedastic. Finite-sample performance of the proposed estimator is examined and compared with other estimators via intensive simulation studies. The proposed method and other methods are applied to a bladder cancer case-control study.

  19. Non-process instrumentation surveillance and test reduction

    International Nuclear Information System (INIS)

    Ferrell, R.; LeDonne, V.; Donat, T.; Thomson, I.; Sarlitto, M.

    1993-12-01

    Analysis of operating experience, instrument failure modes, and degraded instrument performance has led to a reduction in Technical Specification surveillance and test requirements for nuclear power plant process instrumentation. These changes have resulted in lower plant operations and maintenance (O ampersand M) labor costs. This report explores the possibility of realizing similar savings by reducing requirements for non-process instrumentation. The project team reviewed generic Technical Specifications for the four major US nuclear steam supply system (NSSS) vendors (Westinghouse, General Electric, Combustion Engineering, and Babcock ampersand Wilcox) to identify nonprocess instrumentation for which surveillance/test requirements could be reduced. The team surveyed 10 utilities to identify specific non-process instrumentation at their plants for which requirements could be reduced. The team evaluated utility analytic approaches used to justify changes in surveillance/test requirements for process equipment to determine their applicability to non-process instrumentation. The report presents a prioritized list of non-process instrumentation systems suitable for surveillance/test requirements reduction. The top three systems in the list are vibration monitors, leak detection monitors, and chemistry monitors. In general, most non-process instrumentation governed by Technical Specification requirements are candidates for requirements reduction. If statistical requirements are somewhat relaxed, the analytic approaches previously used to reduce requirements for process instrumentation can be applied to non-process instrumentation. The report identifies as viable the technical approaches developed and successfully used by Southern California Edison, Arizona Public Service, and Boston Edison

  20. Mechanistic Physiologically Based Pharmacokinetic (PBPK) Model of the Heart Accounting for Inter-Individual Variability: Development and Performance Verification.

    Science.gov (United States)

    Tylutki, Zofia; Mendyk, Aleksander; Polak, Sebastian

    2018-04-01

    Modern model-based approaches to cardiac safety and efficacy assessment require accurate drug concentration-effect relationship establishment. Thus, knowledge of the active concentration of drugs in heart tissue is desirable along with inter-subject variability influence estimation. To that end, we developed a mechanistic physiologically based pharmacokinetic model of the heart. The models were described with literature-derived parameters and written in R, v.3.4.0. Five parameters were estimated. The model was fitted to amitriptyline and nortriptyline concentrations after an intravenous infusion of amitriptyline. The cardiac model consisted of 5 compartments representing the pericardial fluid, heart extracellular water, and epicardial intracellular, midmyocardial intracellular, and endocardial intracellular fluids. Drug cardiac metabolism, passive diffusion, active efflux, and uptake were included in the model as mechanisms involved in the drug disposition within the heart. The model accounted for inter-individual variability. The estimates of optimized parameters were within physiological ranges. The model performance was verified by simulating 5 clinical studies of amitriptyline intravenous infusion, and the simulated pharmacokinetic profiles agreed with clinical data. The results support the model feasibility. The proposed structure can be tested with the goal of improving the patient-specific model-based cardiac safety assessment and offers a framework for predicting cardiac concentrations of various xenobiotics. Copyright © 2018 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  1. MRI assessment of bone marrow in children with juvenile idiopathic arthritis: intra- and inter-observer variability

    Energy Technology Data Exchange (ETDEWEB)

    Tanturri de Horatio, Laura; Barbuti, Domenico; Toma, Paolo [Ospedale Pediatrico Bambino Gesu, Department of Radiology, Rome (Italy); Damasio, Maria Beatrice [Ospedale G. Gaslini, Department of Radiology, Genoa (Italy); Bracaglia, Claudia [Ospedale Pediatrico Bambino Gesu, Department of Paediatrics, Rome (Italy); Lambot-Juhan, Karen [Hopital Necker-Enfants Malades, Department of Radiology, Paris (France); Boavida, Peter [Great Ormond Street Hospital, Department of Radiology, London (United Kingdom); Ording Mueller, Lil-Sofie [University Hospital North Norway, Department of Radiology, Tromsoe (Norway); Malattia, Clara [Ospedale G. Gaslini, Department of Pediatrics, Genoa (Italy); Rava, Lucilla [Ospedale Pediatrico Bambino Gesu, Department of Epidemiology, Rome (Italy); Rosendahl, Karen [Great Ormond Street Hospital, Department of Radiology, London (United Kingdom); Haukeland University Hospital, Department of Pediatric Radiology, Bergen (Norway)

    2012-06-15

    Bone marrow oedema (BMO) is included in MRI-based scoring systems of disease activity in adults with rheumatoid arthritis. Similar systems in juvenile idiopathic arthritis (JIA) are lacking. To assess the reproducibility in a multi-centre setting of an MRI BMO scoring system in children with JIA. Seventy-six wrist MRIs were read twice, independently, by two experienced paediatric radiologists. BMO was defined as ill-defined lesions within the trabecular bone, returning high and low signal on T2- and T1-weighted images respectively, with or without contrast enhancement. BMO extension was scored for each of 14 bones at the wrist from 0 (none) to 3 (extensive). The intra-observer agreement was moderate to excellent, with weighted kappa ranging from 0.85 to 1.0 and 0.49 to 1.0 (readers 1 and 2 respectively), while the inter-observer agreement ranged from 0.41 to 0.79. The intra- and inter-observer intraclass correlation coefficients were excellent and satisfactory, respectively. The scoring system was reliable and may be used for grading bone marrow abnormality in JIA. The relatively large variability in aggregate scores, particularly between readers, underscores the need for thorough standardisation. (orig.)

  2. MRI assessment of bone marrow in children with juvenile idiopathic arthritis: intra- and inter-observer variability

    International Nuclear Information System (INIS)

    Tanturri de Horatio, Laura; Barbuti, Domenico; Toma, Paolo; Damasio, Maria Beatrice; Bracaglia, Claudia; Lambot-Juhan, Karen; Boavida, Peter; Ording Mueller, Lil-Sofie; Malattia, Clara; Rava, Lucilla; Rosendahl, Karen

    2012-01-01

    Bone marrow oedema (BMO) is included in MRI-based scoring systems of disease activity in adults with rheumatoid arthritis. Similar systems in juvenile idiopathic arthritis (JIA) are lacking. To assess the reproducibility in a multi-centre setting of an MRI BMO scoring system in children with JIA. Seventy-six wrist MRIs were read twice, independently, by two experienced paediatric radiologists. BMO was defined as ill-defined lesions within the trabecular bone, returning high and low signal on T2- and T1-weighted images respectively, with or without contrast enhancement. BMO extension was scored for each of 14 bones at the wrist from 0 (none) to 3 (extensive). The intra-observer agreement was moderate to excellent, with weighted kappa ranging from 0.85 to 1.0 and 0.49 to 1.0 (readers 1 and 2 respectively), while the inter-observer agreement ranged from 0.41 to 0.79. The intra- and inter-observer intraclass correlation coefficients were excellent and satisfactory, respectively. The scoring system was reliable and may be used for grading bone marrow abnormality in JIA. The relatively large variability in aggregate scores, particularly between readers, underscores the need for thorough standardisation. (orig.)

  3. Decoupling Solar Variability and Instrument Trends Using the Multiple Same-Irradiance-Level (MuSIL) Analysis Technique

    Science.gov (United States)

    Woods, Thomas N.; Eparvier, Francis G.; Harder, Jerald; Snow, Martin

    2018-05-01

    The solar spectral irradiance (SSI) dataset is a key record for studying and understanding the energetics and radiation balance in Earth's environment. Understanding the long-term variations of the SSI over timescales of the 11-year solar activity cycle and longer is critical for many Sun-Earth research topics. Satellite measurements of the SSI have been made since the 1970s, most of them in the ultraviolet, but recently also in the visible and near-infrared. A limiting factor for the accuracy of previous solar variability results is the uncertainties for the instrument degradation corrections, which need fairly large corrections relative to the amount of solar cycle variability at some wavelengths. The primary objective of this investigation has been to separate out solar cycle variability and any residual uncorrected instrumental trends in the SSI measurements from the Solar Radiation and Climate Experiment (SORCE) mission and the Thermosphere, Mesosphere, Ionosphere, Energetic, and Dynamics (TIMED) mission. A new technique called the Multiple Same-Irradiance-Level (MuSIL) analysis has been developed, which examines an SSI time series at different levels of solar activity to provide long-term trends in an SSI record, and the most common result is a downward trend that most likely stems from uncorrected instrument degradation. This technique has been applied to each wavelength in the SSI records from SORCE (2003 - present) and TIMED (2002 - present) to provide new solar cycle variability results between 27 nm and 1600 nm with a resolution of about 1 nm at most wavelengths. This technique, which was validated with the highly accurate total solar irradiance (TSI) record, has an estimated relative uncertainty of about 5% of the measured solar cycle variability. The MuSIL results are further validated with the comparison of the new solar cycle variability results from different solar cycles.

  4. The Environmental Trilogy project: Balancing technical, institutional, and cultural perspectives to environmental management

    International Nuclear Information System (INIS)

    Kurstedt, Pamela S.; Jim, Russell; Wadsworth, Bonnie C.W.; Burke, William H.; Kurstedt, Harold A. Jr.

    1992-01-01

    'The significant problems we face cannot be solved at the same level of thinking we were at when we created them.' Albert Einstein. I've identified an initial set of three perspectives important to building an integrated, comprehensive approach to managing the environment - technical, institutional, and cultural. I've constructed an holistic model (called the Environmental Trilogy) for environmental management, encompassing at least these three perspectives and their interrelationships. In this paper, I outline the model and report the results of a working session facilitated at Virginia Tech in Blacksburg, Virginia, in October 1991, involving three representatives from each of the technical, institutional, and cultural perspectives. The institutional members of this group were people who understand institutional effects, rather than those who represent institutions. The working group discussed and analyzed the technical-institutional, technical-cultural, and institutional-cultural inter- relationships of the environmental trilogy. The goals of the working group were to put structure on the environmental trilogy model, to facilitate the definition of variables, and explore relationships between and among variables. The working group members are to continue studying issues and components, perspectives, connections, and cause-and-effect in the models and report back to interested parties. The outcome is projected to be a more holistic, integrated view of the environment. (author)

  5. Technical testing of portable isotope identification instruments

    International Nuclear Information System (INIS)

    Smith, D.E.

    2001-01-01

    Full text: The United States Customs Service has, as a part of its mission, the protection of the borders of the United States from the import or export of illicit radioactive materials. Of paramount importance is the ability to interdict the smuggling of special nuclear material, nuclear weapons and other radioactive materials that could be used as a weapon of mass destruction against the population and infrastructure of the U.S. or another country. Radiation detection technology exists in the form of pocket size, hand-held and portal radiation detectors that have the ability to detect radiation with great sensitivity and low false alarm rates. U.S. Customs has chosen to implement pocket size detectors or radiation pagers as the personal tool of each inspector for the detection of radioactive material. In the search for illicit shipment of radioactive materials, innocent radiation detections may occur with some frequency due to common radioactive sources that may be encountered in day to day living. Examples include lantern mantles, some camera lenses, welding rods, certain dishware containing uranium glaze, and natural marble objects such as statues or architectural pieces. Perhaps the most common innocent detection encountered at the border and in public areas in general is due to the in vivo placement of radioactive sources for use in nuclear medicine therapy and diagnostics. Outpatients from such therapy can remain detectable for three weeks or more. Also, legal shipments of radioisotopes are common occurrences in cargo and express mail shipments. The customs inspector who detects radioactive material in the course of his duties must decide whether detection is innocent; is indicative of a nuclear device or special nuclear material; or whether the source could be injurious to him/her or the general public. It is at this point that a portable instrument capable of identifying gamma or neutron emitting isotopes is essential to the customs examination procedure

  6. Influence of inter-annual environmental variability on chrysophyte cyst assemblages: insight from a 2-years sediment trap study in lakes from northern Poland

    Directory of Open Access Journals (Sweden)

    Iván Hernández-Almeida

    2017-02-01

    Full Text Available Quantitative paleonvironmental studies using transfer functions are developed from training sets. However, changes in some variables (e.g., climatic can be difficult to identify from short-term monitoring (e.g., less than one year. Here, we present the study of the chrysophyte cyst assemblages from sediment traps deployed during two consecutive years (November 2011-November 2013 in 14 lakes from Northern Poland. The studied lakes are distributed along a W-E climatological gradient, with very different physical, chemical and morphological characteristics, and land-uses. Field surveys were carried out to recover the sediment trap material during autumn, along with the measurement of several environmental variables (nutrients, major water ions, conductivity, pH, dissolved oxygen and chlorophyll-a. During the study, one year experienced mild seasonal changes in air temperature (November 2011-November 2012; TS1, typical of oceanic climate, while the other year was characterized by colder winter and spring (November 2012-November 2013; TS2, and higher summer temperatures, more characteristic of continental climate. Other environmental variables (e.g., nutrients did not show great changes between both years. Multivariate statistical analyses (RDA and DCA were performed on individual TS1 and TS2 datasets. Water chemistry and nutrients (pH, TN and TP explained the largest portion of the variance of the chrysophyte data for the individual years. However, analyses of the combined TS1 and TS2 datasets show that strong changes between summer and autumn (warm period, ice-free period with thermal stratification and winter and spring (cold period, ice-cover period play the most important role in the inter-annual variability in the chrysophyte assemblages. We show how inter-annual sampling maximizes ecological gradients of interest, particularly in regions with large environmental diversity, and low climatic variability. This methodology could help to identify

  7. 8 years of Solar Spectral Irradiance Variability Observed from the ISS with the SOLAR/SOLSPEC Instrument

    Science.gov (United States)

    Damé, Luc; Bolsée, David; Meftah, Mustapha; Irbah, Abdenour; Hauchecorne, Alain; Bekki, Slimane; Pereira, Nuno; Cessateur, Marchand; Gäel; , Marion; et al.

    2016-10-01

    Accurate measurements of Solar Spectral Irradiance (SSI) are of primary importance for a better understanding of solar physics and of the impact of solar variability on climate (via Earth's atmospheric photochemistry). The acquisition of a top of atmosphere reference solar spectrum and of its temporal and spectral variability during the unusual solar cycle 24 is of prime interest for these studies. These measurements are performed since April 2008 with the SOLSPEC spectro-radiometer from the far ultraviolet to the infrared (166 nm to 3088 nm). This instrument, developed under a fruitful LATMOS/BIRA-IASB collaboration, is part of the Solar Monitoring Observatory (SOLAR) payload, externally mounted on the Columbus module of the International Space Station (ISS). The SOLAR mission, with its actual 8 years duration, will cover almost the entire solar cycle 24. We present here the in-flight operations and performances of the SOLSPEC instrument, including the engineering corrections, calibrations and improved know-how procedure for aging corrections. Accordingly, a SSI reference spectrum from the UV to the NIR will be presented, together with its variability in the UV, as measured by SOLAR/SOLSPEC for 8 years. Uncertainties on these measurements and comparisons with other instruments will be briefly discussed.

  8. Inter-track interference mitigation with two-dimensional variable equalizer for bit patterned media recording

    Directory of Open Access Journals (Sweden)

    Yao Wang

    2017-05-01

    Full Text Available The increased track density in bit patterned media recording (BPMR causes increased inter-track interference (ITI, which degrades the bit error rate (BER performance. In order to mitigate the effect of the ITI, signals from multiple tracks can be equalized by a 2D equalizer with 1D target. Usually, the 2D fixed equalizer coefficients are obtained by using a pseudo-random bit sequence (PRBS for training. In this study, a 2D variable equalizer is proposed, where various sets of 2D equalizer coefficients are predetermined and stored for different ITI patterns besides the usual PRBS training. For data detection, as the ITI patterns are unknown in the first global iteration, the main and adjacent tracks are equalized with the conventional 2D fixed equalizer, detected with Bahl-Cocke-Jelinek-Raviv (BCJR detector and decoded with low-density parity-check (LDPC decoder. Then using the estimated bit information from main and adjacent tracks, the ITI pattern for each island of the main track can be estimated and the corresponding 2D variable equalizers are used to better equalize the bits on the main track. This process is executed iteratively by feeding back the main track information. Simulation results indicate that for both single-track and two-track detection, the proposed 2D variable equalizer can achieve better BER and frame error rate (FER compared to that with the 2D fixed equalizer.

  9. Job demands and job strain as risk factors for employee wellbeing in elderly care: an instrumental-variables analysis.

    Science.gov (United States)

    Elovainio, Marko; Heponiemi, Tarja; Kuusio, Hannamaria; Jokela, Markus; Aalto, Anna-Mari; Pekkarinen, Laura; Noro, Anja; Finne-Soveri, Harriet; Kivimäki, Mika; Sinervo, Timo

    2015-02-01

    The association between psychosocial work environment and employee wellbeing has repeatedly been shown. However, as environmental evaluations have typically been self-reported, the observed associations may be attributable to reporting bias. Applying instrumental-variable regression, we used staffing level (the ratio of staff to residents) as an unconfounded instrument for self-reported job demands and job strain to predict various indicators of wellbeing (perceived stress, psychological distress and sleeping problems) among 1525 registered nurses, practical nurses and nursing assistants working in elderly care wards. In ordinary regression, higher self-reported job demands and job strain were associated with increased risk of perceived stress, psychological distress and sleeping problems. The effect estimates for the associations of these psychosocial factors with perceived stress and psychological distress were greater, but less precisely estimated, in an instrumental-variables analysis which took into account only the variation in self-reported job demands and job strain that was explained by staffing level. No association between psychosocial factors and sleeping problems was observed with the instrumental-variable analysis. These results support a causal interpretation of high self-reported job demands and job strain being risk factors for employee wellbeing. © The Author 2014. Published by Oxford University Press on behalf of the European Public Health Association. All rights reserved.

  10. Exploring Differences in Measurement and Reporting of Classroom Observation Inter-Rater Reliability

    Science.gov (United States)

    Wilhelm, Anne Garrison; Gillespie Rouse, Amy; Jones, Francesca

    2018-01-01

    Although inter-rater reliability is an important aspect of using observational instruments, it has received little theoretical attention. In this article, we offer some guidance for practitioners and consumers of classroom observations so that they can make decisions about inter-rater reliability, both for study design and in the reporting of data…

  11. Growing Region Segmentation Software (GRES) for quantitative magnetic resonance imaging of multiple sclerosis: intra- and inter-observer agreement variability: a comparison with manual contouring method

    International Nuclear Information System (INIS)

    Parodi, Roberto C.; Sardanelli, Francesco; Renzetti, Paolo; Rosso, Elisabetta; Losacco, Caterina; Ferrari, Alessandra; Levrero, Fabrizio; Pilot, Alberto; Inglese, Matilde; Mancardi, Giovanni L.

    2002-01-01

    Lesion area measurement in multiple sclerosis (MS) is one of the key points in evaluating the natural history and in monitoring the efficacy of treatments. This study was performed to check the intra- and inter-observer agreement variability of a locally developed Growing Region Segmentation Software (GRES), comparing them to those obtained using manual contouring (MC). From routine 1.5-T MRI study of clinically definite multiple sclerosis patients, 36 lesions seen on proton-density-weighted images (PDWI) and 36 enhancing lesion on Gd-DTPA-BMA-enhanced T1-weighted images (Gd-T1WI) were randomly chosen and were evaluated by three observers. The mean range of lesion size was 9.9-536.0 mm 2 on PDWI and 3.6-57.2 mm 2 on Gd-T1WI. The median intra- and inter-observer agreement were, respectively, 97.1 and 90.0% using GRES on PDWI, 81.0 and 70.0% using MC on PDWI, 88.8 and 80.0% using GRES on Gd-T1WI, and 85.8 and 70.0% using MC on Gd-T1WI. The intra- and inter-observer agreements were significantly greater for GRES compared with MC (P<0.0001 and P=0.0023, respectively) for PDWI, while no difference was found between GRES an MC for Gd-T1WI. The intra-observer variability for GRES was significantly lower on both PDWI (P=0.0001) and Gd-T1WI (P=0.0067), whereas for MC the same result was found only for PDWI (P=0.0147). These data indicate that GRES reduces both the intra- and the inter-observer variability in assessing the area of MS lesions on PDWI and may prove useful in multicentre studies. (orig.)

  12. Airborne hygrometer calibration inter-comparison against a metrological water vapour standard

    Science.gov (United States)

    Smorgon, Denis; Boese, Norbert; Ebert, Volker

    2014-05-01

    Water vapour is the most important atmospheric greenhouse gas, which causes a major feedback to warming and other changes in the climate system. Knowledge of the distribution of water vapour and its climate induced changes is especially important in the upper troposphere and lower stratosphere (UT/LS) where vapour plays a critical role in atmospheric radiative balance, cirrus cloud formation, and photochemistry. But, our understanding of water in the UT/LS is limited by significant uncertainties in current UT/LS water measurements. One of the most comprehensive inter-comparison campaigns for airborne hygrometers, termed AQUAVIT (AV1) [1], took place in 2007 at the AIDA chamber at the Karlsruhe Institute of Technology (KIT) in Germany. AV1 was a well-defined, referred, blind inter-comparison of 22 airborne field instruments from 17 international research groups. One major metrological deficit of AV1, however, was, that no traceable reference instrument participated in the inter-comparison experiments and that the calibration procedures of the participating instruments were not monitored or interrogated. Consequently a follow-up inter-comparison was organized in April 2013, which for the first time also provides a traceable link to the international humidity scale. This AQUAVIT2 (AV2) campaign (details see: http://www.imk-aaf.kit.edu/aquavit/index.php/Main_Page) was again located at KIT/AIDA and organised by an international organizing committee including KIT, PTB, FZJ and others. Generally AV2 is divided in two parallel comparisons: 1) AV2-A uses the AIDA chamber for a simultaneous comparison of all instruments (incl. sampling and in-situ instruments) over a broad range of conditions characteristic for the UT/LS; 2) AV2-B, about which this paper is reporting, is a sequential comparison of selected hygrometers and (when possible) their reference calibration infrastructures by means of a chilled mirror hygrometer traced back to the primary National humidity standard

  13. The impact of inter-annual variability of annual cycle on long-term persistence of surface air temperature in long historical records

    Science.gov (United States)

    Deng, Qimin; Nian, Da; Fu, Zuntao

    2018-02-01

    Previous studies in the literature show that the annual cycle of surface air temperature (SAT) is changing in both amplitude and phase, and the SAT departures from the annual cycle are long-term correlated. However, the classical definition of temperature anomalies is based on the assumption that the annual cycle is constant, which contradicts the fact of changing annual cycle. How to quantify the impact of the changing annual cycle on the long-term correlation of temperature anomaly variability still remains open. In this paper, a recently developed data adaptive analysis tool, the nonlinear mode decomposition (NMD), is used to extract and remove time-varying annual cycle to reach the new defined temperature anomalies in which time-dependent amplitude of annual cycle has been considered. By means of detrended fluctuation analysis, the impact induced by inter-annual variability from the time-dependent amplitude of annual cycle has been quantified on the estimation of long-term correlation of long historical temperature anomalies in Europe. The results show that the classical climatology annual cycle is supposed to lack inter-annual fluctuation which will lead to a maximum artificial deviation centering around 600 days. This maximum artificial deviation is crucial to defining the scaling range and estimating the long-term persistence exponent accurately. Selecting different scaling range could lead to an overestimation or underestimation of the long-term persistence exponent. By using NMD method to extract the inter-annual fluctuations of annual cycle, this artificial crossover can be weakened to extend a wider scaling range with fewer uncertainties.

  14. Instrumentation of dynamic gas pulse loading system. Technical progress report, first quarter 1992

    Energy Technology Data Exchange (ETDEWEB)

    Mohaupt, H.

    1992-04-14

    The overall goal of this work is to further develop and field test a system of stimulating oil and gas wells, which increases the effective radius of the well bore so that more oil can flow into it, by recording pressure during the gas generation phase in real time so that fractures can be induced more predictably in the producing formation. Task 1: Complete the laboratory studies currently underway with the prototype model of the instrumentation currently being studied. Task 2: Perform field tests of the model in the Taft/Bakersfield area, utilizing operations closest to the engineers working on the project, and optimize the unit for various conditions encountered there. Task 3: Perform field test of the model in DGPL jobs which are scheduled in the mid-continent area, and optimize the unit for downhole conditions encountered there. Task 4: Analyze and summarize the results achieved during the complete test series, documenting the steps for usage of downhole instrumentation in the field, and compile data specifying use of the technology by others. Task 5: Prepare final report for DOE, and include also a report on the field tests completed. Describe and estimate the probability of the technology being commercialized and in what time span. The project has made substantial technical progress, though we are running about a month behind schedule. Expenditures are in line with the schedule. Increased widespread interest in the use of DGPL stimulation has kept us very busy. The computer modeling and test instrumentation developed under this program is already being applied to commercial operations.

  15. Inter-Labeler and Intra-Labeler Variability of Condition Severity Classification Models Using Active and Passive Learning Methods

    Science.gov (United States)

    Nissim, Nir; Shahar, Yuval; Boland, Mary Regina; Tatonetti, Nicholas P; Elovici, Yuval; Hripcsak, George; Moskovitch, Robert

    2018-01-01

    Background and Objectives Labeling instances by domain experts for classification is often time consuming and expensive. To reduce such labeling efforts, we had proposed the application of active learning (AL) methods, introduced our CAESAR-ALE framework for classifying the severity of clinical conditions, and shown its significant reduction of labeling efforts. The use of any of three AL methods (one well known [SVM-Margin], and two that we introduced [Exploitation and Combination_XA]) significantly reduced (by 48% to 64%) condition labeling efforts, compared to standard passive (random instance-selection) SVM learning. Furthermore, our new AL methods achieved maximal accuracy using 12% fewer labeled cases than the SVM-Margin AL method. However, because labelers have varying levels of expertise, a major issue associated with learning methods, and AL methods in particular, is how to best to use the labeling provided by a committee of labelers. First, we wanted to know, based on the labelers’ learning curves, whether using AL methods (versus standard passive learning methods) has an effect on the Intra-labeler variability (within the learning curve of each labeler) and inter-labeler variability (among the learning curves of different labelers). Then, we wanted to examine the effect of learning (either passively or actively) from the labels created by the majority consensus of a group of labelers. Methods We used our CAESAR-ALE framework for classifying the severity of clinical conditions, the three AL methods and the passive learning method, as mentioned above, to induce the classifications models. We used a dataset of 516 clinical conditions and their severity labeling, represented by features aggregated from the medical records of 1.9 million patients treated at Columbia University Medical Center. We analyzed the variance of the classification performance within (intra-labeler), and especially among (inter-labeler) the classification models that were induced by

  16. Inter-labeler and intra-labeler variability of condition severity classification models using active and passive learning methods.

    Science.gov (United States)

    Nissim, Nir; Shahar, Yuval; Elovici, Yuval; Hripcsak, George; Moskovitch, Robert

    2017-09-01

    Labeling instances by domain experts for classification is often time consuming and expensive. To reduce such labeling efforts, we had proposed the application of active learning (AL) methods, introduced our CAESAR-ALE framework for classifying the severity of clinical conditions, and shown its significant reduction of labeling efforts. The use of any of three AL methods (one well known [SVM-Margin], and two that we introduced [Exploitation and Combination_XA]) significantly reduced (by 48% to 64%) condition labeling efforts, compared to standard passive (random instance-selection) SVM learning. Furthermore, our new AL methods achieved maximal accuracy using 12% fewer labeled cases than the SVM-Margin AL method. However, because labelers have varying levels of expertise, a major issue associated with learning methods, and AL methods in particular, is how to best to use the labeling provided by a committee of labelers. First, we wanted to know, based on the labelers' learning curves, whether using AL methods (versus standard passive learning methods) has an effect on the Intra-labeler variability (within the learning curve of each labeler) and inter-labeler variability (among the learning curves of different labelers). Then, we wanted to examine the effect of learning (either passively or actively) from the labels created by the majority consensus of a group of labelers. We used our CAESAR-ALE framework for classifying the severity of clinical conditions, the three AL methods and the passive learning method, as mentioned above, to induce the classifications models. We used a dataset of 516 clinical conditions and their severity labeling, represented by features aggregated from the medical records of 1.9 million patients treated at Columbia University Medical Center. We analyzed the variance of the classification performance within (intra-labeler), and especially among (inter-labeler) the classification models that were induced by using the labels provided by seven

  17. Trends and inter-annual variability of methane emissions derived from 1979-1993 global CTM simulations

    Directory of Open Access Journals (Sweden)

    F. Dentener

    2003-01-01

    Full Text Available The trend and interannual variability of methane sources are derived from multi-annual simulations of tropospheric photochemistry using a 3-D global chemistry-transport model. Our semi-inverse analysis uses the fifteen years (1979--1993 re-analysis of ECMWF meteorological data and annually varying emissions including photo-chemistry, in conjunction with observed CH4 concentration distributions and trends derived from the NOAA-CMDL surface stations. Dividing the world in four zonal regions (45--90 N, 0--45 N, 0--45 S, 45--90 S we find good agreement in each region between (top-down calculated emission trends from model simulations and (bottom-up estimated anthropogenic emission trends based on the EDGAR global anthropogenic emission database, which amounts for the period 1979--1993 2.7 Tg CH4 yr-1. Also the top-down determined total global methane emission compares well with the total of the bottom-up estimates. We use the difference between the bottom-up and top-down determined emission trends to calculate residual emissions. These residual emissions represent the inter-annual variability of the methane emissions. Simulations have been performed in which the year-to-year meteorology, the emissions of ozone precursor gases, and the stratospheric ozone column distribution are either varied, or kept constant. In studies of methane trends it is most important to include the trends and variability of the oxidant fields. The analyses reveals that the variability of the emissions is of the order of 8Tg CH4 yr-1, and likely related to wetland emissions and/or biomass burning.

  18. Report on inter-noise 99; Inter-noise 99 sanka hokok

    Energy Technology Data Exchange (ETDEWEB)

    Koike, H. [Japan Automobile Research Institute Inc., Tsukuba (Japan)

    2000-04-01

    Inter-Noise (International Congress on Noise Control Engineering) is a society on noise/vibration and the control technology. Inter-Noise 99 was held on December 6, 7 and 8, 1999, at Fort Lauderdale, Florida, the U.S. The theme was Noise Control in the New Millennium. The number of the participants registered was 555 (151 from the U.S., 89 from Japan, 248 from European countries, and 69 from Asian/other countries). Dr. Harold Marshall gave a keynote lecture titled Noise Control by Design in the 21st Century - An Architectural Acoustic Perspective. From a standpoint of architectural acoustics, he stated the perspective, subjects, and course of the technical development pertaining to technologies needed in the 21st century. The papers read are mostly from the following fields: measuring technology, military exercise noise, modeling, forecast and simulation, aerodynamic/underwater sound, etc. In the session on the tire noise where the author read a paper, 14 papers were read. The number of the papers read was more than that in 1998, probably influenced by the tire noise regulation in Europe and Japan. (translated by NEDO)

  19. SU-E-J-176: Characterization of Inter-Fraction Breast Variability and the Implications On Delivered Dose

    Energy Technology Data Exchange (ETDEWEB)

    Sudhoff, M; Lamba, M; Kumar, N; Ward, A; Elson, H [University of Cincinnati, Cincinnati, OH (United States)

    2015-06-15

    Purpose: To systematically characterize inter-fraction breast variability and determine implications on delivered dose. Methods: Weekly port films were used to characterize breast setup variability. Five evenly spaced representative positions across the contour of each breast were chosen on the electronic port film in reference to graticule, and window and level was set such that the skin surface of the breast was visible. Measurements from the skin surface to treatment field edge were taken on each port film at each position and compared to the planning DRR, quantifying the variability. The systematic measurement technique was repeated for all port films for 20 recently treated breast cancer patients. Measured setup variability for each patient was modeled as a normal distribution. The distribution was randomly sampled from the model and applied as isocentric shifts in the treatment planning computer, representing setup variability for each fraction. Dose was calculated for each shifted fraction and summed to obtain DVHs and BEDs that modeled the dose with daily setup variability. Patients were categorized in to relevant groupings that were chosen to investigate the rigorousness of immobilization types, treatment techniques, and inherent anatomical difficulties. Mean position differences and dosimetric differences were evaluated between planned and delivered doses. Results: The setup variability was found to follow a normal distribution with mean position differences between the DRR and port film between − 8.6–3.5 mm with sigma range of 5.3–9.8 mm. Setup position was not found to be significantly different than zero. The mean seroma or whole breast PTV dosimetric difference, calculated as BED, ranged from a −0.23 to +1.13Gy. Conclusion: A systematic technique to quantify and model setup variability was used to calculate the dose in 20 breast cancer patients including variable setup. No statistically significant PTV or OAR BED differences were found between

  20. Runtime party switch in an inter-organizational collaboration

    NARCIS (Netherlands)

    Pourmirza, S.

    2016-01-01

    During the execution of an inter-organizational business-to-business (B2B) collaboration, a collaborating party may drop out for technical reasons or for business reasons. In such a case, the leaving party must be replaced, at runtime, by a new party. Ideally, the new party can pick up where the old

  1. Accuracy and inter-observer variability of 3D versus 4D cone-beam CT based image-guidance in SBRT for lung tumors

    International Nuclear Information System (INIS)

    Sweeney, Reinhart A; Seubert, Benedikt; Stark, Silke; Homann, Vanessa; Müller, Gerd; Flentje, Michael; Guckenberger, Matthias

    2012-01-01

    To analyze the accuracy and inter-observer variability of image-guidance (IG) using 3D or 4D cone-beam CT (CBCT) technology in stereotactic body radiotherapy (SBRT) for lung tumors. Twenty-one consecutive patients treated with image-guided SBRT for primary and secondary lung tumors were basis for this study. A respiration correlated 4D-CT and planning contours served as reference for all IG techniques. Three IG techniques were performed independently by three radiation oncologists (ROs) and three radiotherapy technicians (RTTs). Image-guidance using respiration correlated 4D-CBCT (IG-4D) with automatic registration of the planning 4D-CT and the verification 4D-CBCT was considered gold-standard. Results were compared with two IG techniques using 3D-CBCT: 1) manual registration of the planning internal target volume (ITV) contour and the motion blurred tumor in the 3D-CBCT (IG-ITV); 2) automatic registration of the planning reference CT image and the verification 3D-CBCT (IG-3D). Image quality of 3D-CBCT and 4D-CBCT images was scored on a scale of 1–3, with 1 being best and 3 being worst quality for visual verification of the IGRT results. Image quality was scored significantly worse for 3D-CBCT compared to 4D-CBCT: the worst score of 3 was given in 19 % and 7.1 % observations, respectively. Significant differences in target localization were observed between 4D-CBCT and 3D-CBCT based IG: compared to the reference of IG-4D, tumor positions differed by 1.9 mm ± 0.9 mm (3D vector) on average using IG-ITV and by 3.6 mm ± 3.2 mm using IG-3D; results of IG-ITV were significantly closer to the reference IG-4D compared to IG-3D. Differences between the 4D-CBCT and 3D-CBCT techniques increased significantly with larger motion amplitude of the tumor; analogously, differences increased with worse 3D-CBCT image quality scores. Inter-observer variability was largest in SI direction and was significantly larger in IG using 3D-CBCT compared to 4D-CBCT: 0.6 mm versus 1.5 mm

  2. Accuracy and inter-observer variability of 3D versus 4D cone-beam CT based image-guidance in SBRT for lung tumors

    Directory of Open Access Journals (Sweden)

    Sweeney Reinhart A

    2012-06-01

    Full Text Available Abstract Background To analyze the accuracy and inter-observer variability of image-guidance (IG using 3D or 4D cone-beam CT (CBCT technology in stereotactic body radiotherapy (SBRT for lung tumors. Materials and methods Twenty-one consecutive patients treated with image-guided SBRT for primary and secondary lung tumors were basis for this study. A respiration correlated 4D-CT and planning contours served as reference for all IG techniques. Three IG techniques were performed independently by three radiation oncologists (ROs and three radiotherapy technicians (RTTs. Image-guidance using respiration correlated 4D-CBCT (IG-4D with automatic registration of the planning 4D-CT and the verification 4D-CBCT was considered gold-standard. Results were compared with two IG techniques using 3D-CBCT: 1 manual registration of the planning internal target volume (ITV contour and the motion blurred tumor in the 3D-CBCT (IG-ITV; 2 automatic registration of the planning reference CT image and the verification 3D-CBCT (IG-3D. Image quality of 3D-CBCT and 4D-CBCT images was scored on a scale of 1–3, with 1 being best and 3 being worst quality for visual verification of the IGRT results. Results Image quality was scored significantly worse for 3D-CBCT compared to 4D-CBCT: the worst score of 3 was given in 19 % and 7.1 % observations, respectively. Significant differences in target localization were observed between 4D-CBCT and 3D-CBCT based IG: compared to the reference of IG-4D, tumor positions differed by 1.9 mm ± 0.9 mm (3D vector on average using IG-ITV and by 3.6 mm ± 3.2 mm using IG-3D; results of IG-ITV were significantly closer to the reference IG-4D compared to IG-3D. Differences between the 4D-CBCT and 3D-CBCT techniques increased significantly with larger motion amplitude of the tumor; analogously, differences increased with worse 3D-CBCT image quality scores. Inter-observer variability was largest in SI direction and was

  3. Intra-seasonal and Inter-annual variability of Bowen Ratio over rain-shadow region of North peninsular India

    Science.gov (United States)

    Morwal, S. B.; Narkhedkar, S. G.; Padmakumari, B.; Maheskumar, R. S.; Deshpande, C. G.; Kulkarni, J. R.

    2017-05-01

    Intra-seasonal and inter-annual variability of Bowen Ratio (BR) have been studied over the rain-shadow region of north peninsular India during summer monsoon season. Daily grid point data of latent heat flux (LHF), sensible heat flux (SHF) from NCEP/NCAR Reanalysis for the period 1970-2014 have been used to compute daily area-mean BR. Daily grid point rainfall data at a resolution of 0.25° × 0.25° from APHRODITE's Water Resources for the available period 1970-2007 have been used to study the association between rainfall and BR. The study revealed that BR rapidly decreases from 4.1 to 0.29 in the month of June and then remains nearly constant at the same value (≤0.1) in the rest of the season. High values of BR in the first half of June are indicative of intense thermals and convective clouds with higher bases. Low values of BR from July to September period are indicative of weak thermals and convective clouds with lower bases. Intra-seasonal and inter-annual variability of BR is found to be inversely related to precipitation over the region. BR analysis indicates that the land surface characteristics of the study region during July-September are similar to that over oceanic regions as far as intensity of thermals and associated cloud microphysical properties are concerned. Similar variation of BR is found in El Nino and La Nina years. During June, an increasing trend is observed in SHF and BR and decreasing trend in LHF from 1976 to 2014. Increasing trend in the SHF is statistically significant.

  4. Seasonal and inter-annual temperature variability in the bottom waters over the western Black Sea shelf

    Directory of Open Access Journals (Sweden)

    G. I. Shapiro

    2011-09-01

    Full Text Available Long-term changes in the state of the Bottom Shelf Water (BSW on the Western shelf of the Black Sea are assessed using analysis of intra-seasonal and inter-annual temperature variations. For the purpose of this study the BSW is defined as such shelf water mass between the seabed and the upper mixed layer (bounded by the σθ = 14.2 isopycnal which has limited ability to mix vertically with oxygen-rich surface waters during the warm season due to formation of a seasonal pycnocline. A long-term time series of temperature anomalies in the BSW is constructed from in-situ observations taken over the 2nd half of the 20th century. The BSW is shown to occupy nearly half of the shelf area during the summer stratification period (May–November.The results reveal a warm phase in the 1960s/70s, followed by a cold phase between 1985 and 1995 and a further warming after 1995. The transition between the warm and cold periods coincides with a regime shift in the Black Sea ecosystem. While it was confirmed that the memory of winter convection is well preserved over the following months in the deep sea, the signal of winter cooling in the BSW significantly reduces during the warm season. The potential of the BSW to ventilate horizontally during the warm season with the deep-sea waters is assessed using isopycnic analysis of temperature variations. It is shown that temperature in the BSW is stronger correlated with the temperature of Cold Intermediate Waters (CIW in the deep sea than with the severity of the previous winters, thus indicating that the isopycnal exchanges with the deep sea are more important for inter-annual/inter-decadal variability of the BSW on the western Black Sea shelf than effects of winter convection on the shelf itself.

  5. The Spatio-Temporal Characteristics and Modeling Research of Inter-Provincial Migration in China

    Directory of Open Access Journals (Sweden)

    Xiaomei Fan

    2018-02-01

    Full Text Available The national census data during 1995 and 2000 and during 2005 and 2010 are selected in this paper to make an analysis of the spatio-temporal characteristics of the inter-provincial population migration in China. In addition, the general regression model, the extension regression model considering the historical dependent variable and the spatial lag model are established based on the gravity model to make the regression model on China’s inter-provincial population migration over two periods of time. The results show that: (1 the inter-provincial population migration increases rapidly in size with strong geographical proximity; (2 China’s inter-provincial population migration is still in the primary stage of the general process of population migration. In other words, the inter-provincial population emigration and immigration levels have increased greatly with the economic development; (3 Statistically, the inter-provincial population migration is negatively correlated with the level of economic development in the emigrant place and the migration distance and positively correlated with the level of economic development in the immigrant place and the population scale in the emigrant and immigrant places; and (4 The spatio-temporal factor is an important explanatory variable of population migration. The introduction of the historical dependent variable and the spatial lag factor can improve the regression effect of the gravity model greatly, and the historical variable and the spatial factor have strong explanatory power for the inter-provincial population migration.

  6. An improved estimator for the hydration of fat-free mass from in vivo measurements subject to additive technical errors

    International Nuclear Information System (INIS)

    Kinnamon, Daniel D; Ludwig, David A; Lipshultz, Steven E; Miller, Tracie L; Lipsitz, Stuart R

    2010-01-01

    The hydration of fat-free mass, or hydration fraction (HF), is often defined as a constant body composition parameter in a two-compartment model and then estimated from in vivo measurements. We showed that the widely used estimator for the HF parameter in this model, the mean of the ratios of measured total body water (TBW) to fat-free mass (FFM) in individual subjects, can be inaccurate in the presence of additive technical errors. We then proposed a new instrumental variables estimator that accurately estimates the HF parameter in the presence of such errors. In Monte Carlo simulations, the mean of the ratios of TBW to FFM was an inaccurate estimator of the HF parameter, and inferences based on it had actual type I error rates more than 13 times the nominal 0.05 level under certain conditions. The instrumental variables estimator was accurate and maintained an actual type I error rate close to the nominal level in all simulations. When estimating and performing inference on the HF parameter, the proposed instrumental variables estimator should yield accurate estimates and correct inferences in the presence of additive technical errors, but the mean of the ratios of TBW to FFM in individual subjects may not

  7. Washoe Tribe Nevada Inter-Tribal Energy Consortium Energy Organization Enhancement Project Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Jennifer [Washoe Tribe of NV and Ca

    2014-11-06

    The Washoe Tribe of Nevada and California was awarded funding from the Department of Energy to complete the Nevada Inter-Tribal Energy Consortium Energy Organization Enhancement Project. The main goal of the project was to enhance the capacity of the Nevada Inter-Tribal Energy Consortium (NITEC) to effectively assist tribes within Nevada to technically manage tribal energy resources and implement tribal energy projects.

  8. Issues related to the inter-utility transfer of material

    International Nuclear Information System (INIS)

    1993-08-01

    An option that utilities have for obtaining material is to procure the desired item(s) from another utility. There are several reasons utilities choose another utility as the procurement source including item obsolescence, prohibitive cost on the commercial market, and excessive lead time. This document provides information on the technical, quality, and commercial issues which utilities may need to address when selling material to or procuring material from other utilities. This report provides suggested approaches for each of the following technical and quality issues: Design considerations; item acceptability considerations; original supplier considerations; commercial grade item dedication considerations; reportability considerations; packaging, shipping, and storage considerations; documentation considerations; receipt inspection considerations. The information is provided primarily for the inter-utility transfer of safety-related material. Several of the topics, however, may also apply to the transfer of non-safety-related material. The report also provides considerations on commercial issues which may be addressed during the inter-utility transfer of materials

  9. Inter-model variability and biases of the global water cycle in CMIP3 coupled climate models

    International Nuclear Information System (INIS)

    Liepert, Beate G; Previdi, Michael

    2012-01-01

    Observed changes such as increasing global temperatures and the intensification of the global water cycle in the 20th century are robust results of coupled general circulation models (CGCMs). In spite of these successes, model-to-model variability and biases that are small in first order climate responses, however, have considerable implications for climate predictability especially when multi-model means are used. We show that most climate simulations of the 20th and 21st century A2 scenario performed with CMIP3 (Coupled Model Inter-comparison Project Phase 3) models have deficiencies in simulating the global atmospheric moisture balance. Large biases of only a few models (some biases reach the simulated global precipitation changes in the 20th and 21st centuries) affect the multi-model mean global moisture budget. An imbalanced flux of −0.14 Sv exists while the multi-model median imbalance is only −0.02 Sv. Moreover, for most models the detected imbalance changes over time. As a consequence, in 13 of the 18 CMIP3 models examined, global annual mean precipitation exceeds global evaporation, indicating that there should be a ‘leaking’ of moisture from the atmosphere whereas for the remaining five models a ‘flooding’ is implied. Nonetheless, in all models, the actual atmospheric moisture content and its variability correctly increases during the course of the 20th and 21st centuries. These discrepancies therefore imply an unphysical and hence ‘ghost’ sink/source of atmospheric moisture in the models whose atmospheres flood/leak. The ghost source/sink of moisture can also be regarded as atmospheric latent heating/cooling and hence as positive/negative perturbation of the atmospheric energy budget or non-radiative forcing in the range of −1 to +6 W m −2 (median +0.1 W m −2 ). The inter-model variability of the global atmospheric moisture transport from oceans to land areas, which impacts the terrestrial water cycle, is also quite high and ranges

  10. Inter- and intra-annual chemical variability during the ice-free season in lakes with different flushing rates and acid deposition histories.

    Science.gov (United States)

    Arnott, Shelley E; Dillon, Peter J; Somers, Keith; Keller, Bill

    2003-01-01

    Quantifying chemical variability in different lake types is important for the assessment of both chemical and biological responses to environmental change. For monitoring programs that emphasize a large number of lakes at the expense of frequent samples, high variability may influence how representative single samples are of the average conditions of individual lakes. Intensive temporal data from long-term research sites provide a unique opportunity to assess chemical variability in lakes with different characteristics. We compared the intra- and inter-annual variability of four acidification related variables (Gran alkalinity, pH, sulphate concentration, and total base cation concentration) in four lakes with different flushing rates and acid deposition histories. Variability was highest in lakes with high flushing rates and was not influenced by historic acid deposition in our study lakes. This has implications for the amount of effort required in monitoring programs. Lakes with high flushing rates will require more frequent sampling intervals than lakes with low flushing rates. Consideration of specific lake types should be included in the design of monitoring programs.

  11. Technical Support Section Instrument Support Program for nuclear and nonnuclear facilities with safety requirements

    International Nuclear Information System (INIS)

    Adkisson, B.P.; Allison, K.L.

    1995-01-01

    This document describes requirements, procedures, and supervisory responsibilities of the Oak Ridge National Laboratory (ORNL) Instrumentation and Controls (I ampersand C) Division's Technical Support Section (TSS) for instrument surveillance and maintenance in nonreactor nuclear facilities having identified Operational Safety Requirements (OSRs) or Limiting Conditions Document (LCDs). Implementation of requirements comply with the requirements of U.S. Department of Energy (DOE) Orders 5480.5, 5480.22, and 5481.1B; Martin Marietta Energy Systems, Inc. (Energy Systems), Policy Procedure ESS-FS-201; and ORNL SPP X-ESH-15. OSRs and LCDs constitute an agreement or contract between DOE and the facility operating management regarding the safe operation of the facility. One basic difference between OSRs and LCDs is that violation of an OSR is considered a Category II occurrence, whereas violation of an LCD requirement is considered a Category III occurrence (see Energy Systems Standard ESS-OP-301 and ORNL SPP X-GP-13). OSRs are required for high- and moderate-hazard nuclear facilities, whereas the less-rigorous LCDs are required for low-hazard nuclear facilities and selected open-quotes generally acceptedclose quotes operations. Hazard classifications are determined through a hazard screening process, which each division conducts for its facilities

  12. The Science of String Instruments

    CERN Document Server

    Rossing, Thomas D

    2010-01-01

    Many performing musicians, as well as instrument builders, are coming to realize the importance of understanding the science of musical instruments. This book explains how string instruments produce sound. It presents basic ideas in simple language, and it also translates some more sophisticated ideas in non-technical language. It should be of interest to performers, researchers, and instrument makers alike.

  13. Three-dimensional echocardiography: assessment of inter- and intra-operator variability and accuracy in the measurement of left ventricular cavity volume and myocardial mass

    International Nuclear Information System (INIS)

    Nadkarni, S.K.; Drangova, M.; Boughner, D.R.; Fenster, A.; Department of Medical Biophysics, Medical Sciences Building, University of Western Ontario, London, Ontario N6A 5C1

    2000-01-01

    Accurate left ventricular (LV) volume and mass estimation is a strong predictor of cardiovascular morbidity and mortality. We propose that our technique of 3D echocardiography provides an accurate quantification of LV volume and mass by the reconstruction of 2D images into 3D volumes, thus avoiding the need for geometric assumptions. We compared the accuracy and variability in LV volume and mass measurement using 3D echocardiography with 2D echocardiography, using in vitro studies. Six operators measured the LV volume and mass of seven porcine hearts, using both 3D and 2D techniques. Regression analysis was used to test the accuracy of results and an ANOVA test was used to compute variability in measurement. LV volume measurement accuracy was 9.8% (3D) and 18.4% (2D); LV mass measurement accuracy was 5% (3D) and 9.2% (2D). Variability in LV volume quantification with 3D echocardiography was %SEM inter = 13.5%, %SEM intra = 11.4%, and for 2D echocardiography was %SEM inter = 21.5%, %SEM intra = 19.1%. We derived an equation to predict uncertainty in measurement of LV volume and mass using 3D echocardiography, the results of which agreed with our experimental results to within 13%. 3D echocardiography provided twice the accuracy for LV volume and mass measurement and half the variability for LV volume measurement as compared with 2D echocardiography. (author)

  14. Inter-subject variability of muscle synergies during bench press in power lifters and untrained individuals.

    Science.gov (United States)

    Kristiansen, M; Madeleine, P; Hansen, E A; Samani, A

    2015-02-01

    The purpose of the study was to elucidate the role of expertise on muscle synergies involved in bench press. Ten expert power lifters (EXP) and nine untrained participants (UNT) completed three sets of eight repetitions at 60% of three repetition maximum in bench press. Muscle synergies were extracted from surface electromyography data of 21 bench press cycles using non-negative matrix factorization algorithm. The synergy activation coefficient represents the relative contribution of the muscle synergy to the overall muscle activity pattern, while the muscle synergy vector represents the relative weighting of each muscle within each synergy. Describing more than 90% of the variability, two muscle synergies reflected the eccentric and concentric phase. The cross-correlations (ρ(max)) for synergy activation coefficient 2 (concentric phase) were 0.83 [0.71;0.88] and 0.59 [0.49;0.77] [Median ρ(max) (25th;75th percentile)] (P = 0.001) in UNT and EXP, respectively. Median correlation coefficient (ρ) for muscle synergy vector 2 was 0.15 [-0.08;0.46] and 0.48 [0.02;0.70] (P = 0.03) in UNT and EXP, respectively. Thus, EXP showed larger inter-subject variability than UNT in the synergy activation coefficient during the concentric phase, while the muscle synergy vectors were less variable in EXP. This points at the importance of a specialized neural strategy in elite bench press performance. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Technical forums as an instrument for knowledge management in oil pipelines and terminals companies: the experience of TRANSPETRO

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Maria Fatima Ludovico de [Pontificia Universidade Catolica do Rio de Janeiro (PUC-Rio/ITUC), Rio de Janeiro, RJ (Brazil). Instituto Tecnologico; Santiago, Adilson; Ribeiro, Kassandra Senra; Arruda, Daniela Mendonca [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2009-07-01

    This paper describes the experience of TRANSPETRO's Oil Pipelines and Terminals Unit regarding an institutionalized knowledge management (KM) process of systematically promoting technical forums focused on: pipeline and terminal operations; industrial maintenance; and right-of-way activities management. This empirical work adds evidence that in the model of cooperative and communicative knowledge management it is necessary to motivate staff to provide the company with their tacit knowledge and to take a proactive part in knowledge management processes, particularly in technical forums. Within this KM perspective, technical forums have been held by TRANSPETRO for the following purposes: to discuss the main barriers and challenges the oil pipelines and terminals unit has to face in the coming years; to share and disseminate good practices concerning oil pipeline and terminal activities; to discuss new processes, methods and equipment developments with potential application in business and operational processes; to establish action plans concerning the main challenges, barriers and opportunities; to disseminate Research and Development (R and D) projects in course, new procedures, methods and equipment and to promote integration among forum attendees. The two year-experience in TRANSPETRO's Oil Pipelines and Terminals Unit revealed that technical forums have been an important instrument for cooperative and communicative knowledge management, according to evaluations from 173 attendees. (author)

  16. Technical forums as an instrument for knowledge management in oil pipelines and terminals companies: the experience of TRANSPETRO

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Maria Fatima Ludovico de [Pontificia Universidade Catolica do Rio de Janeiro (PUC-Rio/ITUC), Rio de Janeiro, RJ (Brazil). Instituto Tecnologico; Santiago, Adilson; Ribeiro, Kassandra Senra; Arruda, Daniela Mendonca [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2009-07-01

    This paper describes the experience of TRANSPETRO's Oil Pipelines and Terminals Unit regarding an institutionalized knowledge management (KM) process of systematically promoting technical forums focused on: pipeline and terminal operations; industrial maintenance; and right-of-way activities management. This empirical work adds evidence that in the model of cooperative and communicative knowledge management it is necessary to motivate staff to provide the company with their tacit knowledge and to take a proactive part in knowledge management processes, particularly in technical forums. Within this KM perspective, technical forums have been held by TRANSPETRO for the following purposes: to discuss the main barriers and challenges the oil pipelines and terminals unit has to face in the coming years; to share and disseminate good practices concerning oil pipeline and terminal activities; to discuss new processes, methods and equipment developments with potential application in business and operational processes; to establish action plans concerning the main challenges, barriers and opportunities; to disseminate Research and Development (R and D) projects in course, new procedures, methods and equipment and to promote integration among forum attendees. The two year-experience in TRANSPETRO's Oil Pipelines and Terminals Unit revealed that technical forums have been an important instrument for cooperative and communicative knowledge management, according to evaluations from 173 attendees. (author)

  17. Seasonal and inter-annual variability of the phytoplankton communities in an upwelling area of the Alborán Sea (SW Mediterranean Sea

    Directory of Open Access Journals (Sweden)

    Jesús M. Mercado

    2005-12-01

    Full Text Available Temporal variability (seasonal and inter-annual in the assembly of phytoplankton communities from the northern Alborán Sea was investigated. For this purpose, the taxonomic composition of the micro- and nano-phytoplankton communities at three fixed stations was determined every three months from 1994 to 2002. A total of 357 different taxa were identified. Most of them (about 54% were diatom species belonging to 57 genera. Dinoflagellates and coccolitophorids accounted for 118 and 30 taxa respectively. Two time periods could be differentiated with respect to the cell abundance. Thus, the mean abundance from 1994 to 1999 was 338 cell ml-1 and it dropped to about 60 cell ml-1 during the period 2000-2002. Diatoms and un-identified small flagellates dominated the communities during this first period, although a significant increase in the abundance of coccolitophorids occurred after 1997. Pseudo-nitzschia, Leptocylindrus and Chaetoceros were the dominant genera. In contrast, the coccolitophorids Emiliania huxleyi and Gephyrocapsa spp. quantitatively dominated the communities from 2000 to 2002. These shifts in the community assembly were assessed by performing a sample-oriented stepwise discriminant analysis (SDA. The analysis separated the samples into three year-groups, with great inter-annual variability. In contrast, the SDA did not find any seasonal sucessional pattern. In spite of this result, chlorophyll a and cell abundance tended to be higher in the spring period, which has been described for the whole Alborán basin. The nutrient concentrations in the 75 m upper seawater layer had inter-annual fluctuations. Thus, NO3-+NO2-, PO4-3 and Si(OH4 concentrations decreased significantly in 1997-1998. Additionally, lower Si(OH4 concentrations and Si:P molar ratios were obtained in 2000. These results suggest that the inter-annual shifts in the phytoplankton taxonomic composition were due to alterations in the nutrient regime. In this paper we

  18. Evaluating disease management programme effectiveness: an introduction to instrumental variables.

    Science.gov (United States)

    Linden, Ariel; Adams, John L

    2006-04-01

    This paper introduces the concept of instrumental variables (IVs) as a means of providing an unbiased estimate of treatment effects in evaluating disease management (DM) programme effectiveness. Model development is described using zip codes as the IV. Three diabetes DM outcomes were evaluated: annual diabetes costs, emergency department (ED) visits and hospital days. Both ordinary least squares (OLS) and IV estimates showed a significant treatment effect for diabetes costs (P = 0.011) but neither model produced a significant treatment effect for ED visits. However, the IV estimate showed a significant treatment effect for hospital days (P = 0.006) whereas the OLS model did not. These results illustrate the utility of IV estimation when the OLS model is sensitive to the confounding effect of hidden bias.

  19. Effects of modified Pilates on variability of inter-joint coordination during walking in the elderly.

    Science.gov (United States)

    Yoon, Sukhoon; Kim, Joo Nyeon; Lim, Hee Sung

    2016-12-01

    [Purpose] This study aimed to examine the effects of an 8-week modified Pilates program on the variability of inter-joint coordination in the elderly during walking. [Subjects and Methods] Twenty elderly participants with no recent history of orthopedic abnormalities (age, 67.9 ± 2.7 years; height, 163.7 ± 8.9 cm; weight, 67.1 ± 11.6 kg) were recruited for this study and randomly allocated to a modified Pilates exercise group or a control group. Three-dimensional motion analysis was performed on both groups to evaluate the effects of the Pilates exercise. [Results] There was no significant difference in the joint variability of the ankle, knee, and hip joints between the groups, both before training and after training. However, there was a significant increase in the hip-knee deviation phase value in the exercise group after the program was completed, and this increase was also significant when compared with that in the control group. [Conclusion] This study has demonstrated that an 8-week modified Pilates exercise program can have a positive impact on the gait of elderly participants, potentially by enhancing neuromuscular adjustment, which may have positive implications for reducing their fall risk.

  20. Inter- and Intra-individual variability following intermittent theta burst stimulation: implications for rehabilitation and recovery.

    Science.gov (United States)

    Hinder, Mark R; Goss, Emily L; Fujiyama, Hakuei; Canty, Alison J; Garry, Michael I; Rodger, Jennifer; Summers, Jeffery J

    2014-01-01

    The continued refinement of non-invasive brain stimulation (NBS) techniques is indicative of promising clinical and rehabilitative interventions that are able to modulate cortical excitability. Intermittent theta burst stimulation (iTBS) is one such technique that can increase cortical excitability, purportedly via LTP-like mechanisms. While iTBS may have the capacity to promote recovery after neurological injury, and to combat cognitive and motor decline, recent reports observed highly variable effects across individuals, questioning the efficacy of iTBS as a clinical tool. The aim of this study was to examine intra-individual reliability and inter-individual variability in responses to iTBS. Thirty healthy participants completed two experimental sessions of the iTBS protocol 1-3 weeks apart. Motor evoked potentials in response to single pulse TMS were used to assess corticospinal excitability prior to, and up to 36 min following, iTBS. At the group level, iTBS evoked statistically significant increases in motor cortical excitability across both sessions (P iTBS is capable of inducing relatively robust and consistent effects within and between young individuals. As such, the capacity for iTBS to be exploited in clinical and rehabilitative interventions should continue to be explored. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Standardization of 8-color flow cytometry across different flow cytometer instruments: A feasibility study in clinical laboratories in Switzerland.

    Science.gov (United States)

    Glier, Hana; Heijnen, Ingmar; Hauwel, Mathieu; Dirks, Jan; Quarroz, Stéphane; Lehmann, Thomas; Rovo, Alicia; Arn, Kornelius; Matthes, Thomas; Hogan, Cassandra; Keller, Peter; Dudkiewicz, Ewa; Stüssi, Georg; Fernandez, Paula

    2017-07-29

    The EuroFlow Consortium developed a fully standardized flow cytometric approach from instrument settings, through antibody panel, reagents and sample preparation protocols, to data acquisition and analysis. The Swiss Cytometry Society (SCS) promoted a study to evaluate the feasibility of using such standardized measurements of 8-color data across two different flow cytometry platforms - Becton Dickinson (BD) FACSCanto II and Beckman Coulter (BC) Navios, aiming at increasing reproducibility and inter-laboratory comparability of immunophenotypic data in clinical laboratories in Switzerland. The study was performed in two phases, i.e. a learning phase (round 1) and an analytical phase (rounds 2 and 3) consisting of a total of three rounds. Overall, 10 laboratories using BD FACSCanto II (n=6) or BC Navios (n=4) flow cytometers participated. Each laboratory measured peripheral blood samples from healthy donors stained with a uniform antibody panel of reagents - EuroFlow Lymphoid Screening Tube (LST) - applying the EuroFlow standardized protocols for instrument setup and sample preparation (www.EuroFlow.org). All data files were analyzed centrally and median fluorescence intensity (MedFI) values for individual markers on defined lymphocyte subsets were recorded; variability from reference MedFI values was assessed using performance scores. Data troubleshooting and discussion of the results with the participants followed after each round at SCS meetings. The results of the learning phase demonstrated that standardized instrument setup and data acquisition are feasible in routine clinical laboratories without previous experience with EuroFlow. During the analytical phase, highly comparable data were obtained at the different laboratories using either BD FACSCanto II or BC Navios. The coefficient of variation of MedFI for 7 of 11 markers performed repeatedly below 30%. In the last study round, 89% of participants scored over 90% MedFI values within the acceptance criteria

  2. Non-technical skills assessment for prelicensure nursing students: An integrative review.

    Science.gov (United States)

    Pires, Sara; Monteiro, Sara; Pereira, Anabela; Chaló, Daniela; Melo, Elsa; Rodrigues, Alexandre

    2017-11-01

    In nursing, non-technical skills are recognized as playing an important role to increase patient safety and successful clinical outcomes (Pearson and McLafferty, 2011). Non-technical skills are cognitive and social resource skills that complement technical skills and contribute to safe and efficient task performance (Flin et al., 2008). In order to effectively provide non-technical skills training, it is essential to have an instrument to measure these skills. An online search was conducted. Articles were selected if they referred to and/or described instruments assessing non-technical skills for nurses and/or prelicensure nursing students in educational, clinical and/or simulated settings with validation evidence (inclusion criteria). Of the 53 articles located, 26 met the inclusion criteria. Those referred to and/or described 16 instruments with validation evidence developed to assess non-technical skills in multidisciplinary teams including nurses. Although articles have shown 16 valid and reliable instruments, to our knowledge, no instrument has been published or developed and validated for the assessment of non-technical skills of only nurses in general, relevant for use in high-fidelity simulation-based training for prelicensure nursing students. Therefore, there is a need for the development of such an instrument. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Inter- and Intra-method Variability of VS Profiles and VS30 at ARRA-funded Sites

    Science.gov (United States)

    Yong, A.; Boatwright, J.; Martin, A. J.

    2015-12-01

    The 2009 American Recovery and Reinvestment Act (ARRA) funded geophysical site characterizations at 191 seismographic stations in California and in the central and eastern United States. Shallow boreholes were considered cost- and environmentally-prohibitive, thus non-invasive methods (passive and active surface- and body-wave techniques) were used at these stations. The drawback, however, is that these techniques measure seismic properties indirectly and introduce more uncertainty than borehole methods. The principal methods applied were Array Microtremor (AM), Multi-channel Analysis of Surface Waves (MASW; Rayleigh and Love waves), Spectral Analysis of Surface Waves (SASW), Refraction Microtremor (ReMi), and P- and S-wave refraction tomography. Depending on the apparent geologic or seismic complexity of the site, field crews applied one or a combination of these methods to estimate the shear-wave velocity (VS) profile and calculate VS30, the time-averaged VS to a depth of 30 meters. We study the inter- and intra-method variability of VS and VS30 at each seismographic station where combinations of techniques were applied. For each site, we find both types of variability in VS30 remain insignificant (5-10% difference) despite substantial variability observed in the VS profiles. We also find that reliable VS profiles are best developed using a combination of techniques, e.g., surface-wave VS profiles correlated against P-wave tomography to constrain variables (Poisson's ratio and density) that are key depth-dependent parameters used in modeling VS profiles. The most reliable results are based on surface- or body-wave profiles correlated against independent observations such as material properties inferred from outcropping geology nearby. For example, mapped geology describes station CI.LJR as a hard rock site (VS30 > 760 m/s). However, decomposed rock outcrops were found nearby and support the estimated VS30 of 303 m/s derived from the MASW (Love wave) profile.

  4. Trojan technical specification verification project

    International Nuclear Information System (INIS)

    Bates, L.; Rickenback, M.

    1991-01-01

    The Trojan Technical Specification Verification (TTSV) project at the Trojan plant of Portland General Electric Company was motivated by the recognition that many numbers in the Trojan technical specifications (TTS) potentially lacked the consideration of instrument- and/or process-related errors. The plant setpoints were known to consider such errors, but many of the values associated with the limiting conditions for operation (LCO) did not. In addition, the existing plant instrument error analyses were based on industry values that do not reflect the Trojan plant-specific experience. The purpose of this project is to ensure that the Trojan plant setpoint and LCO values include plant-specific instrument error

  5. QNOTE: an instrument for measuring the quality of EHR clinical notes.

    Science.gov (United States)

    Burke, Harry B; Hoang, Albert; Becher, Dorothy; Fontelo, Paul; Liu, Fang; Stephens, Mark; Pangaro, Louis N; Sessums, Laura L; O'Malley, Patrick; Baxi, Nancy S; Bunt, Christopher W; Capaldi, Vincent F; Chen, Julie M; Cooper, Barbara A; Djuric, David A; Hodge, Joshua A; Kane, Shawn; Magee, Charles; Makary, Zizette R; Mallory, Renee M; Miller, Thomas; Saperstein, Adam; Servey, Jessica; Gimbel, Ronald W

    2014-01-01

    The outpatient clinical note documents the clinician's information collection, problem assessment, and patient management, yet there is currently no validated instrument to measure the quality of the electronic clinical note. This study evaluated the validity of the QNOTE instrument, which assesses 12 elements in the clinical note, for measuring the quality of clinical notes. It also compared its performance with a global instrument that assesses the clinical note as a whole. Retrospective multicenter blinded study of the clinical notes of 100 outpatients with type 2 diabetes mellitus who had been seen in clinic on at least three occasions. The 300 notes were rated by eight general internal medicine and eight family medicine practicing physicians. The QNOTE instrument scored the quality of the note as the sum of a set of 12 note element scores, and its inter-rater agreement was measured by the intraclass correlation coefficient. The Global instrument scored the note in its entirety, and its inter-rater agreement was measured by the Fleiss κ. The overall QNOTE inter-rater agreement was 0.82 (CI 0.80 to 0.84), and its note quality score was 65 (CI 64 to 66). The Global inter-rater agreement was 0.24 (CI 0.19 to 0.29), and its note quality score was 52 (CI 49 to 55). The QNOTE quality scores were consistent, and the overall QNOTE score was significantly higher than the overall Global score (p=0.04). We found the QNOTE to be a valid instrument for evaluating the quality of electronic clinical notes, and its performance was superior to that of the Global instrument. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  6. Modelling Inter-relationships among water, governance, human development variables in developing countries with Bayesian networks.

    Science.gov (United States)

    Dondeynaz, C.; Lopez-Puga, J.; Carmona-Moreno, C.

    2012-04-01

    Improving Water and Sanitation Services (WSS), being a complex and interdisciplinary issue, passes through collaboration and coordination of different sectors (environment, health, economic activities, governance, and international cooperation). This inter-dependency has been recognised with the adoption of the "Integrated Water Resources Management" principles that push for the integration of these various dimensions involved in WSS delivery to ensure an efficient and sustainable management. The understanding of these interrelations appears as crucial for decision makers in the water sector in particular in developing countries where WSS still represent an important leverage for livelihood improvement. In this framework, the Joint Research Centre of the European Commission has developed a coherent database (WatSan4Dev database) containing 29 indicators from environmental, socio-economic, governance and financial aid flows data focusing on developing countries (Celine et al, 2011 under publication). The aim of this work is to model the WatSan4Dev dataset using probabilistic models to identify the key variables influencing or being influenced by the water supply and sanitation access levels. Bayesian Network Models are suitable to map the conditional dependencies between variables and also allows ordering variables by level of influence on the dependent variable. Separated models have been built for water supply and for sanitation because of different behaviour. The models are validated if complying with statistical criteria but either with scientific knowledge and literature. A two steps approach has been adopted to build the structure of the model; Bayesian network is first built for each thematic cluster of variables (e.g governance, agricultural pressure, or human development) keeping a detailed level for interpretation later one. A global model is then built based on significant indicators of each cluster being previously modelled. The structure of the

  7. Impact of instrumental response on observed ozonesonde profiles: First-order estimates and implications for measures of variability

    Science.gov (United States)

    Clifton, G. T.; Merrill, J. T.; Johnson, B. J.; Oltmans, S. J.

    2009-12-01

    Ozonesondes provide information on the ozone distribution up to the middle stratosphere. Ozone profiles often feature layers, with vertically discrete maxima and minima in the mixing ratio. Layers are especially common in the UT/LS regions and originate from wave breaking, shearing and other transport processes. ECC sondes, however, have a moderate response time to significant changes in ozone. A sonde can ascend over 350 meters before it responds fully to a step change in ozone. This results in an overestimate of the altitude assigned to layers and an underestimate of the underlying variability in the amount of ozone. An estimate of the response time is made for each instrument during the preparation for flight, but the profile data are typically not processed to account for the response. Here we present a method of categorizing the response time of ECC instruments and an analysis of a low-pass filter approximation to the effects on profile data. Exponential functions were fit to the step-up and step-down responses using laboratory data. The resulting response time estimates were consistent with results from standard procedures, with the up-step response time exceeding the down-step value somewhat. A single-pole Butterworth filter that approximates the instrumental effect was used with synthetic layered profiles to make first-order estimates of the impact of the finite response time. Using a layer analysis program previously applied to observed profiles we find that instrumental effects can attenuate ozone variability by 20-45% in individual layers, but that the vertical offset in layer altitudes is moderate, up to about 150 meters. We will present results obtained using this approach, coupled with data on the distribution of layer characteristics found using the layer analysis procedure on profiles from Narragansett, Rhode Island and other US sites to quantify the impact on overall variability estimates given ambient distributions of layer occurrence, thickness

  8. Aiming for excellence - A simulation-based study on adapting and testing an instrument for developing non-technical skills in Norwegian student nurse anaesthetists.

    Science.gov (United States)

    Flynn, Fiona M; Sandaker, Kjersti; Ballangrud, Randi

    2017-01-01

    There is increasing focus on building safety into anaesthesia practice, with excellence in anaesthesia as an aspirational goal. Non-technical skills are an important factor in excellence and improved patient safety, though there have been few systematic attempts at integrating them into anaesthesia nursing education. This study aimed to test the reliability of NANTS-no, a specially adapted behavioural marker system for nurse anaesthetists in Norway, and explore the development of non-technical skills in student nurse anaesthetists. The pre-test post-test design incorporated a 10-week simulation-based programme, where non-technical skills in 14 student nurse anaesthetists were rated on three different occasions during high-fidelity simulation, before and after taking part in a training course. NANTS-no demonstrated high overall inter-rater reliability (ICC = 0.91), high test-retest reliability (ICC = 0.94) and good internal consistency (Cronbach's α of 0.85-0.92). A significant improvement was demonstrated across all categories of non-technical skills, with greatest improvements between the first and third and second and third sessions. There was also a significant improvement in two categories between the first and second sessions. NANTS-no is therefore suitable for assessing non-technical skills during simulation training in anaesthesia nursing education. More research is needed to validate its use in clinical practice. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Technical Stability and Biological Variability in MicroRNAs from Dried Blood Spots: A Lung Cancer Therapy-Monitoring Showcase.

    Science.gov (United States)

    Kahraman, Mustafa; Laufer, Thomas; Backes, Christina; Schrörs, Hannah; Fehlmann, Tobias; Ludwig, Nicole; Kohlhaas, Jochen; Meese, Eckart; Wehler, Thomas; Bals, Robert; Keller, Andreas

    2017-09-01

    Different work flows have been proposed to use miRNAs as blood-borne biomarkers. In particular, the method used for collecting blood from patients can considerably influence the diagnostic results. We explored whether dried blood spots (DBSs) facilitate stable miRNA measurements and compared its technical stability with biological variability. First, we tested the stability of DBS samples by generating from 1 person 18 whole-genome-wide miRNA profiles of DBS samples that were exposed to different temperature and humidity conditions. Second, we investigated technical reproducibility by performing 7 replicates of DBS again from 1 person. Third, we investigated DBS samples from 53 patients with lung cancer undergoing different therapies. Across these 3 stages, 108 genome-wide miRNA profiles from DBS were generated and evaluated biostatistically. In the stability analysis, we observed that temperature and humidity had an overall limited influence on the miRNomes (average correlation between the different conditions of 0.993). Usage of a silica gel slightly diminished DBS' technical reproducibility. The 7 technical replicates had an average correlation of 0.996. The correlation with whole-blood PAXGene miRNomes of the same individual was remarkable (correlation of 0.88). Finally, evaluation of the samples from the 53 patients with lung cancer exposed to different therapies showed that the biological variations exceeded the technical variability significantly ( P work flow for profiling of whole miRNomes on the basis of samples collected from DBS. Biological variations exceeded technical variations significantly. DBS-based miRNA profiles will potentially further the translational character of miRNA biomarker studies. © 2017 American Association for Clinical Chemistry.

  10. Hydroclimate variability: comparing dendroclimatic records and future GCM scenarios

    International Nuclear Information System (INIS)

    Lapp, S.

    2008-01-01

    Drought events of the 20th Century in western North America have been linked to teleconnections that influence climate variability on inter-annual and decadal to multi-decadal time scales. These teleconnections represent the changes sea surface temperatures (SSTs) in the tropical and extra-tropical regions of the Pacific Ocean, ENSO (El-Nino Southern Oscillation) and PDO (Pacific Decadal Oscillation), respectively, and the Atlantic Ocean, AMO (Atlantic Multidecadal Oscillation), and also to atmospheric circulation patterns (PNA: Pacific-North American). A network of precipitation sensitive tree-ring chronologies from Montana, Alberta, Saskatchewan and NWT highly correlate to the climate moisture index (CMI) of precipitation potential evapotranspiration (P-PET), thus, capturing the long-term hydroclimatic variability of the region. Reconstructions of annual and seasonal CMI identify drought events in previous centuries that are more extreme in magnitude, frequency and duration than recorded during the instrumental period. Variability in the future climate will include these natural climate cycles as well as modulations of these cycles affected by human induced global warming. The proxy hydroclimate records derived from tree-rings present information on decadal and multi-decadal hydroclimatic variability for the past millennium; therefore, providing a unique opportunity to validate the climate variability simulated by GCMs (Global Climate Models) on longer time scales otherwise constrained by the shorter observation records. Developing scenarios of future variability depends: 1) on our understanding of the interaction of these teleconnection; and, 2) to identify climate models that are able to accurately simulate the hydroclimatic variability as detected in the instrumental and proxy records. (author)

  11. The effect of inter-annual variability of consumption, production, trade and climate on crop-related green and blue water footprints and inter-regional virtual water trade: A study for China (1978-2008).

    Science.gov (United States)

    Zhuo, La; Mekonnen, Mesfin M; Hoekstra, Arjen Y

    2016-05-01

    Previous studies into the relation between human consumption and indirect water resources use have unveiled the remote connections in virtual water (VW) trade networks, which show how communities externalize their water footprint (WF) to places far beyond their own region, but little has been done to understand variability in time. This study quantifies the effect of inter-annual variability of consumption, production, trade and climate on WF and VW trade, using China over the period 1978-2008 as a case study. Evapotranspiration, crop yields and green and blue WFs of crops are estimated at a 5 × 5 arc-minute resolution for 22 crops, for each year in the study period, thus accounting for climate variability. The results show that crop yield improvements during the study period helped to reduce the national average WF of crop consumption per capita by 23%, with a decreasing contribution to the total from cereals and increasing contribution from oil crops. The total consumptive WFs of national crop consumption and crop production, however, grew by 6% and 7%, respectively. By 2008, 28% of total water consumption in crop fields in China served the production of crops for export to other regions and, on average, 35% of the crop-related WF of a Chinese consumer was outside its own province. Historically, the net VW within China was from the water-rich South to the water-scarce North, but intensifying North-to-South crop trade reversed the net VW flow since 2000, which amounted 6% of North's WF of crop production in 2008. South China thus gradually became dependent on food supply from the water-scarce North. Besides, during the whole study period, China's domestic inter-regional VW flows went dominantly from areas with a relatively large to areas with a relatively small blue WF per unit of crop, which in 2008 resulted in a trade-related blue water loss of 7% of the national total blue WF of crop production. The case of China shows that domestic trade, as governed by

  12. Institution, Financial Sector, and Economic Growth: Use The Institutions As An Instrument Variable

    OpenAIRE

    Albertus Girik Allo

    2016-01-01

    Institution has been investigated having indirect role on economic growth. This paper aims to evaluate whether the quality of institution matters for economic growth. By applying institution as instrumental variable at Foreign Direct Investment (FDI), quality of institution significantly influence economic growth. This study applies two set of data period, namely 1985-2013 and 2000-2013, available online in the World Bank (WB). The first data set, 1985-2013 is used to estimate the role of fin...

  13. Instrumentation reference book

    CERN Document Server

    Boyes, Walt

    2002-01-01

    Instrumentation is not a clearly defined subject, having a 'fuzzy' boundary with a number of other disciplines. Often categorized as either 'techniques' or 'applications' this book addresses the various applications that may be needed with reference to the practical techniques that are available for the instrumentation or measurement of a specific physical quantity or quality. This makes it of direct interest to anyone working in the process, control and instrumentation fields where these measurements are essential.* Comprehensive and authoritative collection of technical information* Writte

  14. CMO Site: Ocean Instrumentation

    Science.gov (United States)

    1997-02-01

    Precipitation , Lightning, Visibility 0150 A InterOcea Hawser Strain 1.. systems, inc. and more... n 1946 3540 aero court san diego ca 92123-1799 usa phone: (619...AGU’s Microgal culture Association, P.O. Box 1004, April 8-10, 1997-Underwater Gravimetry : Instruments, Observa- Niland, CA 92257; (619) 359-3474

  15. Inter-subject variability modulates phonological advance planning in the production of adjective-noun phrases.

    Science.gov (United States)

    Michel Lange, Violaine; Laganaro, Marina

    2014-01-01

    The literature on advance phonological planning in adjective-noun phrases (NPs) presents diverging results: while many experimental studies suggest that the entire NP is encoded before articulation, other results favor a span of encoding limited to the first word. Although cross-linguistic differences in the structure of adjective-NPs may account for some of these contrasting results, divergences have been reported even among similar languages and syntactic structures. Here we examined whether inter-individual differences account for variability in the span of phonological planning in the production of French NPs, where previous results indicated encoding limited to the first word. The span of phonological encoding is tested with the picture-word interference (PWI) paradigm using phonological distractors related to the noun or to the adjective of the NPs. In Experiment 1, phonological priming effects were limited to the first word in adjective NPs whichever the position of the adjective (pre-nominal or post-nominal). Crucially, phonological priming effects on the second word interacted with speakers' production speed suggesting different encoding strategies for participants. In Experiment 2, we tested this hypothesis further with a larger group of participants. Results clearly showed that slow and fast initializing participants presented different phonological priming patterns on the last element of adjective-NPs: while the first word was primed by a distractor for all speakers, only the slow speaker group presented a priming effect on the second element of the NP. These results show that the span of phonological encoding is modulated by inter-individual strategies: in experimental paradigms some speakers plan word by word whereas others encode beyond the initial word. We suggest that the diverging results reported in the literature on advance phonological planning may partly be reconciled in light of the present results.

  16. DOE Fundamentals Handbook: Instrumentation and Control, Volume 2

    International Nuclear Information System (INIS)

    1992-06-01

    The Instrumentation and Control Fundamentals Handbook personnel, and the technical staff facility operating contractors provide operators, maintenance personnel, and the technical staff with the necessary fundamentals training to ensure a basic understanding of instrumentation and control systems. The handbook includes information on temperature, pressure, flow, and level detection systems; position indication systems; process control systems; and radiation detection principles. This information will provide personnel with an understanding of the basic operation of various types of DOE nuclear facility instrumentation and control systems

  17. Seasonal and inter-annual variability of sea surface temperature at the east coast fishing area off Peninsular Malaysia

    Science.gov (United States)

    Nurul Ridani, S.; Mustapha, M. A.; Lihan, T.; Ku Kassim, K. Y.; Raja Bidin, R. H.

    2015-09-01

    Empirical orthogonal function (EOF) analysis was used to study a time-series of the aqua MODIS data imageries in the exclusive economic zone of east coast off Peninsular Malaysia. Temporal and spatial characteristics were examined to determine the dominant pattern of sea surface temperature (SST) variability from January 2003 to December 2011.The data were analysed from daily Level 1A (1km spatial resolution) to monthly composites Level 3 data using SeaDAS and ERDAS imagine software. Four modes was obtained from the analysis with the highest variance (7.9%) represented by mode 1 which explained the seasonal cycle. Mode 2 (5.11 % of total variance) showed positive and negative peak signal during March and April and in October and November with variability near the Kelantan and Pahang waters that indicated the inter monsoon. Mode 3 (3.8 % of variance) shows variability near the Terengganu, Kelantan and Johor waters to the open sea during July and August and in May and June representing the Southwest monsoon. Mode 4 (3.36 %) showed positive signal during November and December with strong signal near Pahang and Kelantan waters while weak signal was detected near Terengganu and Kelantan's open sea representing the Northeast monsoon. The SST variability was influenced by the monsoonal system which originated by the wind forcing condition that influences circulation in the study area.

  18. 47 CFR 25.213 - Inter-Service coordination requirements for the 1.6/2.4 GHz mobile-satellite service.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Inter-Service coordination requirements for the 1.6/2.4 GHz mobile-satellite service. 25.213 Section 25.213 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES SATELLITE COMMUNICATIONS Technical Standards § 25.213 Inter...

  19. Technical and instrumentational foundations of PET/MRI

    NARCIS (Netherlands)

    Rausch, Ivo; Quick, Harald H.; Cal-Gonzalez, Jacobo; Sattler, Bernhard; Boellaard, Ronald; Beyer, Thomas

    This paper highlights the origins of combined positron emission tomography (PET) and magnetic resonance imaging (MRI) whole-body systems that were first introduced for applications in humans in 2010. This text first covers basic aspects of each imaging modality before describing the technical and

  20. Definition of gross tumor volume in lung cancer: inter-observer variability

    NARCIS (Netherlands)

    van de Steene, Jan; Linthout, Nadine; de Mey, Johan; Vinh-Hung, Vincent; Claassens, Cornelia; Noppen, Marc; Bel, Arjan; Storme, Guy

    2002-01-01

    BACKGROUND AND PURPOSE: To determine the inter-observer variation in gross tumor volume (GTV) definition in lung cancer, and its clinical relevance. MATERIALS AND METHODS: Five clinicians involved in lung cancer were asked to define GTV on the planning CT scan of eight patients. Resulting GTVs were

  1. Physical fitness predicts technical-tactical and time-motion profile in simulated Judo and Brazilian Jiu-Jitsu matches

    Directory of Open Access Journals (Sweden)

    Victor S. Coswig

    2018-05-01

    Full Text Available Background Among combat sports, Judo and Brazilian Jiu-Jitsu (BJJ present elevated physical fitness demands from the high-intensity intermittent efforts. However, information regarding how metabolic and neuromuscular physical fitness is associated with technical-tactical performance in Judo and BJJ fights is not available. This study aimed to relate indicators of physical fitness with combat performance variables in Judo and BJJ. Methods The sample consisted of Judo (n = 16 and BJJ (n = 24 male athletes. At the first meeting, the physical tests were applied and, in the second, simulated fights were performed for later notational analysis. Results The main findings indicate: (i high reproducibility of the proposed instrument and protocol used for notational analysis in a mobile device; (ii differences in the technical-tactical and time-motion patterns between modalities; (iii performance-related variables are different in Judo and BJJ; and (iv regression models based on metabolic fitness variables may account for up to 53% of the variances in technical-tactical and/or time-motion variables in Judo and up to 31% in BJJ, whereas neuromuscular fitness models can reach values up to 44 and 73% of prediction in Judo and BJJ, respectively. When all components are combined, they can explain up to 90% of high intensity actions in Judo. Discussion In conclusion, performance prediction models in simulated combat indicate that anaerobic, aerobic and neuromuscular fitness variables contribute to explain time-motion variables associated with high intensity and technical-tactical variables in Judo and BJJ fights.

  2. Inter Annual Variability of the Acoustic Propagation in the Yellow Sea Identified from a Synoptic Monthly Gridded Database as Compared with GDEM

    Science.gov (United States)

    2016-09-01

    resolution in SMG-WOD, and thus less data levels for such shallow water . A comprehensive collection of salinity images by years can be found in the...DISTRIBUTION CODE 13. ABSTRACT (maximum 200 words ) This research investigates the inter-annual acoustic variability in the Yellow Sea identified from...is a semi-enclosed basin located between China and Korea with a mean depth of 40m; acoustics are driven by shallow water dynamics and interaction with

  3. Implementing and Evaluating a National Certification Technical Skills Examination: The Colorectal Objective Structured Assessment of Technical Skill.

    Science.gov (United States)

    de Montbrun, Sandra; Roberts, Patricia L; Satterthwaite, Lisa; MacRae, Helen

    2016-07-01

    To implement the Colorectal Objective Structured Assessment of Technical skill (COSATS) into American Board of Colon and Rectal Surgery (ABCRS) certification and build evidence of validity for the interpretation of the scores of this high stakes assessment tool. Currently, technical skill assessment is not a formal component of board certification. With the technical demands of surgical specialties, documenting competence in technical skill at the time of certification with a valid tool is ideal. In September 2014, the COSATS was a mandatory component of ABCRS certification. Seventy candidates took the examination, with their performance evaluated by expert colorectal surgeons using a task-specific checklist, global rating scale, and overall performance scale. Passing scores were set and compared using 2 standard setting methodologies, using a compensatory and conjunctive model. Inter-rater reliability and the reliability of the pass/fail decision were calculated using Cronbach alpha and Subkoviak methodology, respectively. Overall COSATS scores and pass/fail status were compared with results on the ABCRS oral examination. The pass rate ranged from 85.7% to 90%. Inter-rater reliability (0.85) and reliability of the pass/fail decision (0.87 and 0.84) were high. A low positive correlation (r= 0.25) was seen between the COSATS and oral examination. All individuals who failed the COSATS passed the ABCRS oral examination. COSATS is the first technical skill examination used in national surgical board certification. This study suggests that the current certification process may be failing to identify individuals who have demonstrated technical deficiencies on this standardized assessment tool.

  4. Instrumentation development

    International Nuclear Information System (INIS)

    Ubbes, W.F.; Yow, J.L. Jr.

    1988-01-01

    Instrumentation is developed for the Civilian Radioactive Waste Management Program to meet several different (and sometimes conflicting) objectives. This paper addresses instrumentation development for data needs that are related either directly or indirectly to a repository site, but does not touch on instrumentation for work with waste forms or other materials. Consequently, this implies a relatively large scale for the measurements, and an in situ setting for instrument performance. In this context, instruments are needed for site characterization to define phenomena, develop models, and obtain parameter values, and for later design and performance confirmation testing in the constructed repository. The former set of applications is more immediate, and is driven by the needs of program design and performance assessment activities. A host of general technical and nontechnical issues have arisen to challenge instrumentation development. Instruments can be classed into geomechanical, geohydrologic, or other specialty categories, but these issues cut across artificial classifications. These issues are outlined. Despite this imposing list of issues, several case histories are cited to evaluate progress in the area

  5. Genetic variability and inter-character associations in the mutants of Indian mustard

    International Nuclear Information System (INIS)

    Labana, K.S.; Chaurasia, B.D.; Singh, Balwant

    1980-01-01

    To study the genetic variability and the inter-character associations in Indian mustard [Brassica juncea (Linn.)Czern. and Coss. subsp. juncea Linn.], 104 radiation-induced mutants (including 'RLM 198') and 'RL 18' were grown during winter season of 1976-77 at the experimental farm of the Punjab Agricultural University. Analysis of variance revealed significant differences between the mutant genotypes for all the characters under study except for the primary branch number and siliqua number of main shoot, which were non-significant. High estimates of phenotypic coefficients of variation (pcv) and genetic coefficients of variation (gcv) were observed for secondary branch number, seed yield/plant, main shoot length and seed number/siliqua. In general, pcv estimates were higher than gcv estimates. The high estimates of both heritability and genetic advance were recorded in similar order for the plant height, seed number/siliqua, main shoot length and seed yield, in which the genetic progress could be achieved through mass selection. Seed yield was positively correlated with the primary branch number, the secondary branch number and the siliqua number of main shoot and negatively with the plant height. Shorter plant height w;.th more number of primary and secondary branches and more siliquae on main shoot were found to be good selection criteria for isolating high-yielding strains. (auth.)

  6. Toward human resource management in inter-professional health practice: linking organizational culture, group identity and individual autonomy.

    Science.gov (United States)

    Tataw, David

    2012-01-01

    The literature on team and inter-professional care practice describes numerous barriers to the institutionalization of inter-professional healthcare. Responses to slow institutionalization of inter-professional healthcare practice have failed to describe change variables and to identify change agents relevant to inter-professional healthcare practice. The purpose of this paper is to (1) describe individual and organizational level barriers to collaborative practice in healthcare; (2) identify change variables relevant to the institutionalization of inter-professional practice at individual and organizational levels of analysis; and (3) identify human resource professionals as change agents and describe how the strategic use of the human resource function could transform individual and organizational level change variables and therefore facilitate the healthcare system's shift toward inter-professional practice. A proposed program of institutionalization includes the following components: a strategic plan to align human resource functions with organizational level inter-professional healthcare strategies, activities to enhance professional competencies and the organizational position of human resource personnel, activities to integrate inter-professional healthcare practices into the daily routines of institutional and individual providers, activities to stand up health provider champions as permanent leaders of inter-professional teams with human resource professionals as consultants and activities to bring all key players to the table including health providers. Copyright © 2012 John Wiley & Sons, Ltd.

  7. 22 CFR 1003.4 - Inter-American Foundation system of records requirements.

    Science.gov (United States)

    2010-04-01

    ..., technical, and physical safeguards to insure the security and confidentiality of records and to protect against any anticipated threats or hazards to their security or integrity which could result in..., retention, and disposal of the records; (6) The title and business address of the Inter-American Foundation...

  8. Technical evaluation of the electrical, instrumentation, and control design aspects of the low temperature overpressure protection system for the Haddam Neck Nuclear Power Plant

    International Nuclear Information System (INIS)

    Laudenbach, D.H.

    1979-03-01

    The technical evaluation of the electrical, instrumentation, and control design aspects of the low temperature overpressure protection system for the Haddam Neck Nuclear Power Plant is presented. Design basis criteria used to evaluate the acceptability of the system included operator action, system testability, single failure criterion, and seismic Category I and IEEE Std-279-1971 criteria. This report is supplied as part of the Selected Electrical, Instrumentation, and Control Systems Issues Support Program being conducted for the U.S. Nuclear Regulatory Commission by Lawrence Livermore Laboratory

  9. Inter-physician agreement on the readiness of sick-listed employees to return to work.

    Science.gov (United States)

    Schreuder, Jolanda A H; Roelen, Corné A M; de Boer, Mintje; Brouwer, Sandra; Groothoff, Johan W

    2012-01-01

    To determine the agreement between occupational physician (OP) ratings of an employee's readiness to return to work (RRTW). Anonymized written vignettes of 132 employees, sick-listed for at least 3 weeks, were reviewed by 5 OPs. The OPs intuitively rated RRTW as the ability (knowledge and skills) and willingness (motivation and confidence) of sick-listed employees to resume work. Inter-OP percentages of agreement were calculated and Cohen's kappas (κ) were determined to correct for agreement by chance. The percentage of agreement between OPs was 57% (range 39-89%) on the ability and 63% (range 48-87%) on the willingness of sick-listed employees to resume work. The mean κ was 0.14 (range from -0.21 to 0.79) for ability and 0.25 (range from -0.11 to 0.74) for willingness. The OP-rating of RRTW of employees sick-listed with mental disorders did not differ from the OP-rating of RRTW of employees with musculoskeletal disorders. The inter-OP agreement on intuitively rated RRTW showed a wide variability, which accentuates the need for instruments to establish an employee's RRTW and for training in giving well founded return to work recommendations.

  10. Dosimetric impact of inter-observer variability for 3D conformal radiotherapy and volumetric modulated arc therapy: the rectal tumor target definition case

    International Nuclear Information System (INIS)

    Lobefalo, Francesca; Cozzi, Luca; Scorsetti, Marta; Mancosu, Pietro; Bignardi, Mario; Reggiori, Giacomo; Tozzi, Angelo; Tomatis, Stefano; Alongi, Filippo; Fogliata, Antonella; Gaudino, Anna; Navarria, Piera

    2013-01-01

    To assess the dosimetric effect induced by inter-observer variability in target definition for 3D-conformal RT (3DCRT) and volumetric modulated arc therapy by RapidArc (RA) techniques for rectal cancer treatment. Ten patients with rectal cancer subjected to neo-adjuvant RT were randomly selected from the internal database. Four radiation oncologists independently contoured the clinical target volume (CTV) in blind mode. Planning target volume (PTV) was defined as CTV + 7 mm in the three directions. Afterwards, shared guidelines between radiation oncologists were introduced to give general criteria for the contouring of rectal target and the four radiation oncologists defined new CTV following the guidelines. For each patient, six intersections (I) and unions (U) volumes were calculated coupling the contours of the various oncologists. This was repeated for the contours drawn after the guidelines. Agreement Index (AI = I/U) was calculated pre and post guidelines. Two RT plans (one with 3DCRT technique using 3–4 fields and one with RA using a single modulated arc) were optimized on each radiation oncologist’s PTV. For each plan the PTV volume receiving at least 95% of the prescribed dose (PTV V95%) was calculated for both target and non-target PTVs. The inter-operator AI pre-guidelines was 0.57 and was increased up to 0.69 post-guidelines. The maximum volume difference between the various CTV couples, drawn for each patient, passed from 380 ± 147 cm 3 to 137 ± 83 cm 3 after the introduction of guidelines. The mean percentage for the non-target PTV V95% was 93.7 ± 9.2% before and 96.6 ± 4.9%after the introduction of guidelines for the 3DCRT, for RA the increase was more relevant, passing from 86.5 ± 13.8% (pre) to 94.5 ± 7.5% (post). The OARs were maximally spared with VMAT technique while the variability between pre and post guidelines was not relevant in both techniques. The contouring inter-observer variability has dosimetric effects in the PTV coverage

  11. Institution, Financial Sector, and Economic Growth: Use The Institutions As An Instrument Variable

    Directory of Open Access Journals (Sweden)

    Albertus Girik Allo

    2016-06-01

    Full Text Available Institution has been investigated having indirect role on economic growth. This paper aims to evaluate whether the quality of institution matters for economic growth. By applying institution as instrumental variable at Foreign Direct Investment (FDI, quality of institution significantly influence economic growth. This study applies two set of data period, namely 1985-2013 and 2000-2013, available online in the World Bank (WB. The first data set, 1985-2013 is used to estimate the role of financial sector on economic growth, focuses on 67 countries. The second data set, 2000-2013 determine the role of institution on financial sector and economic growth by applying 2SLS estimation method. We define institutional variables as set of indicators: Control of Corruption, Political Stability and Absence of Violence, and Voice and Accountability provide declining impact of FDI to economic growth.

  12. Social interactions and college enrollment: A combined school fixed effects/instrumental variables approach.

    Science.gov (United States)

    Fletcher, Jason M

    2015-07-01

    This paper provides some of the first evidence of peer effects in college enrollment decisions. There are several empirical challenges in assessing the influences of peers in this context, including the endogeneity of high school, shared group-level unobservables, and identifying policy-relevant parameters of social interactions models. This paper addresses these issues by using an instrumental variables/fixed effects approach that compares students in the same school but different grade-levels who are thus exposed to different sets of classmates. In particular, plausibly exogenous variation in peers' parents' college expectations are used as an instrument for peers' college choices. Preferred specifications indicate that increasing a student's exposure to college-going peers by ten percentage points is predicted to raise the student's probability of enrolling in college by 4 percentage points. This effect is roughly half the magnitude of growing up in a household with married parents (vs. an unmarried household). Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Technical and regulatory challenges for digital instrumentation and control and control room systems in nuclear plants

    International Nuclear Information System (INIS)

    Torok, R.; Naser, J.; Harris, T.; Keithline, K.

    2006-01-01

    There are several unsettled technical and licensing issues in the areas of instrumentation and control (I and C), human factors, and updated control room designs that need coordinated, proactive industry attention. Some of these issues are already causing protracted regulatory reviews for existing plants, and left untreated, may cause substantial delays and increased costs for new plant combined construction and operating license approvals. Both industry and the NRC will have roles in resolving the key issues and addressing them in future design efforts and regulatory reviews. Where action is needed, the industry will want to minimize costs and risks by defining industry consensus solutions with corresponding technical bases. NEI has formed a working group to coordinate industry efforts and communications with NRC staff. The working group will also help determine priorities and coordinate both new and existing plant resources. EPRI will provide technical input and guidance for the working group. In order to be able to conduct reviews in a timely fashion, the NRC will likely need to enhance and expand staff resources as existing plants are upgraded and new plant reviews become more active. The industry initiative began with a workshop sponsored by EPRI and NEI on March 28-29, 2006, which led to the creation of the NEI working group. The working group has now identified and prioritized important generic issues, established resolution paths and schedules, and identified the roles of various stakeholders including utility companies, EPRI, NEI, vendors and the NRC. Through the course of this initiative I and C issues for both existing and new plants are being addressed. This paper describes the key I and C related technical and regulatory issues and their implications for new and operating plants, and provides a status report on the efforts to resolve them. (authors)

  14. An Integrated Workflow To Assess Technical and Biological Variability of Cell Population Frequencies in Human Peripheral Blood by Flow Cytometry.

    Science.gov (United States)

    Burel, Julie G; Qian, Yu; Lindestam Arlehamn, Cecilia; Weiskopf, Daniela; Zapardiel-Gonzalo, Jose; Taplitz, Randy; Gilman, Robert H; Saito, Mayuko; de Silva, Aruna D; Vijayanand, Pandurangan; Scheuermann, Richard H; Sette, Alessandro; Peters, Bjoern

    2017-02-15

    In the context of large-scale human system immunology studies, controlling for technical and biological variability is crucial to ensure that experimental data support research conclusions. In this study, we report on a universal workflow to evaluate both technical and biological variation in multiparameter flow cytometry, applied to the development of a 10-color panel to identify all major cell populations and T cell subsets in cryopreserved PBMC. Replicate runs from a control donation and comparison of different gating strategies assessed the technical variability associated with each cell population and permitted the calculation of a quality control score. Applying our panel to a large collection of PBMC samples, we found that most cell populations showed low intraindividual variability over time. In contrast, certain subpopulations such as CD56 T cells and Temra CD4 T cells were associated with high interindividual variability. Age but not gender had a significant effect on the frequency of several populations, with a drastic decrease in naive T cells observed in older donors. Ethnicity also influenced a significant proportion of immune cell population frequencies, emphasizing the need to account for these covariates in immune profiling studies. We also exemplify the usefulness of our workflow by identifying a novel cell-subset signature of latent tuberculosis infection. Thus, our study provides a universal workflow to establish and evaluate any flow cytometry panel in systems immunology studies. Copyright © 2017 by The American Association of Immunologists, Inc.

  15. Technical memorandum: instrumentation for APT and LTPP

    CSIR Research Space (South Africa)

    Steyn, WJvdM

    2006-01-01

    Full Text Available . In these phases, the parameters to be monitored on APT and LTPP sections have been identified, appropriate instruments and sensors for monitoring these parameters have been identified, and recommendations made regarding new developments, required upgrading...

  16. TECHNICAL CULTURE AND HUMAN AXJOSPHERE

    Directory of Open Access Journals (Sweden)

    ­Krystyna Chałas

    2014-11-01

    Full Text Available Technical culture is the value of each historical period. It is the subject of the ongoing development. While it is a value which is associated with different categories of values, mainly material, cognitive, social. Between culture and these three categories of values ​ there is a cognitive effect. Technical culture determines the quality of human axjosphere. The aim of this study is to show the relationships and dependencies between technical culture and the structures in which a person lives and works. It is mainly about the answer to the question of which values of technical culture are closely related to and what are the inter dependencies? The primary task is to define the concept of the technical culture and to show its teaching essence. The second task boils down to indicate the range of values ​​inherent in the culture of technology, determining the value of the technological culture and values, which are developed by the technical culture. Indication of the interaction between the technical culture and values ​​is the third task.

  17. Reliability of visual and instrumental color matching.

    Science.gov (United States)

    Igiel, Christopher; Lehmann, Karl Martin; Ghinea, Razvan; Weyhrauch, Michael; Hangx, Ysbrand; Scheller, Herbert; Paravina, Rade D

    2017-09-01

    The aim of this investigation was to evaluate intra-rater and inter-rater reliability of visual and instrumental shade matching. Forty individuals with normal color perception participated in this study. The right maxillary central incisor of a teaching model was prepared and restored with 10 feldspathic all-ceramic crowns of different shades. A shade matching session consisted of the observer (rater) visually selecting the best match by using VITA classical A1-D4 (VC) and VITA Toothguide 3D Master (3D) shade guides and the VITA Easyshade Advance intraoral spectrophotometer (ES) to obtain both VC and 3D matches. Three shade matching sessions were held with 4 to 6 weeks between sessions. Intra-rater reliability was assessed based on the percentage of agreement for the three sessions for the same observer, whereas the inter-rater reliability was calculated as mean percentage of agreement between different observers. The Fleiss' Kappa statistical analysis was used to evaluate visual inter-rater reliability. The mean intra-rater reliability for the visual shade selection was 64(11) for VC and 48(10) for 3D. The corresponding ES values were 96(4) for both VC and 3D. The percentages of observers who matched the same shade with VC and 3D were 55(10) and 43(12), respectively, while corresponding ES values were 88(8) for VC and 92(4) for 3D. The results for visual shade matching exhibited a high to moderate level of inconsistency for both intra-rater and inter-rater comparisons. The VITA Easyshade Advance intraoral spectrophotometer exhibited significantly better reliability compared with visual shade selection. This study evaluates the ability of observers to consistently match the same shade visually and with a dental spectrophotometer in different sessions. The intra-rater and inter-rater reliability (agreement of repeated shade matching) of visual and instrumental tooth color matching strongly suggest the use of color matching instruments as a supplementary tool in

  18. Development and Psychometric Properties of an Assessment for Persons with Intellectual Disability--The InterRAI ID

    Science.gov (United States)

    Martin, Lynn; Hirdes, John P.; Fries, Brant E.; Smith, Trevor F.

    2007-01-01

    This paper describes the development of the interRAI-Intellectual Disability (interRAI ID), a comprehensive instrument that assesses all key domains of interest to service providers relative to a person with an intellectual disability (ID). The authors report on the reliability and validity of embedded scales for cognition, self-care, aggression,…

  19. Tropopause referenced ozone climatology and inter-annual variability (1994–2003 from the MOZAIC programme

    Directory of Open Access Journals (Sweden)

    Thouret

    2006-01-01

    Full Text Available The MOZAIC programme collects ozone and water vapour data using automatic equipment installed on board five long-range Airbus A340 aircraft flying regularly all over the world since August 1994. Those measurements made between September 1994 and August 1996 allowed the first accurate ozone climatology at 9–12 km altitude to be generated. The seasonal variability of the tropopause height has always provided a problem when constructing climatologies in this region. To remove any signal from the seasonal and synoptic scale variability in tropopause height we have chosen in this further study of these and subsequent data to reference our climatology to the altitude of the tropopause. We define the tropopause as a mixing zone 30 hPa thick across the 2 pvu potential vorticity surface. A new ozone climatology is now available for levels characteristic of the upper troposphere (UT and the lower stratosphere (LS regardless of the seasonal variations of the tropopause over the period 1994–2003. Moreover, this new presentation has allowed an estimation of the monthly mean climatological ozone concentration at the tropopause showing a sine seasonal variation with a maximum in May (120 ppbv and a minimum in November (65 ppbv. Besides, we present a first assessment of the inter-annual variability of ozone in this particular critical region. The overall increase in the UTLS is about 1%/yr for the 9 years sampled. However, enhanced concentrations about 10–15 % higher than the other years were recorded in 1998 and 1999 in both the UT and the LS. This so-called '1998–1999 anomaly' may be attributed to a combination of different processes involving large scale modes of atmospheric variability, circulation features and local or global pollution, but the most dominant one seems to involve the variability of the North Atlantic Oscillation (NAO as we find a strong positive correlation (above 0.60 between ozone recorded in the upper troposphere and the NAO

  20. DEVELOPING EVALUATION INSTRUMENT FOR MATHEMATICS EDUCATIONAL SOFTWARE

    Directory of Open Access Journals (Sweden)

    Wahyu Setyaningrum

    2012-02-01

    Full Text Available The rapid increase and availability of mathematics software, either for classroom or individual learning activities, presents a challenge for teachers. It has been argued that many products are limited in quality. Some of the more commonly used software products have been criticized for poor content, activities which fail to address some learning issues, poor graphics presentation, inadequate documentation, and other technical problems. The challenge for schools is to ensure that the educational software used in classrooms is appropriate and effective in supporting intended outcomes and goals. This paper aimed to develop instrument for evaluating mathematics educational software in order to help teachers in selecting the appropriate software. The instrument considers the notion of educational including content, teaching and learning skill, interaction, and feedback and error correction; and technical aspects of educational software including design, clarity, assessment and documentation, cost and hardware and software interdependence. The instrument use a checklist approach, the easier and effective methods in assessing the quality of educational software, thus the user needs to put tick in each criteria. The criteria in this instrument are adapted and extended from standard evaluation instrument in several references.   Keywords: mathematics educational software, educational aspect, technical aspect.

  1. Impact of inter-seasonal solar variability on the association of lower troposphere and cold point tropopause in the tropics: Observations using RO data from COSMIC

    Science.gov (United States)

    Kumar, V.; Dhaka, S. K.; Ho, Shu-Peng; Singh, Narendra; Singh, Vir; Reddy, K. K.; Chun, H.-Y.

    2017-12-01

    Association of lower tropospheric variations with the cold point tropopause (CPT) is examined on inter-seasonal basis over the tropical region (30°N-30°S) during 2007-2010 using COSMIC/FORMOST-3 Radio Occultation (RO) data. Temperature analyses for this association are shown over different regions of the globe having contrast topography namely over Western Pacific sector, Indian sector, and African sector. Correlation coefficient (r), taken as a measurement of association, show specific longitudinal differences between the lower troposphere (from 1 km to 5 km height) and the CPT. The northern and southern hemispheres show contrast coupling of temperature variation between lower tropospheric region and the CPT. Land and ocean effects are found to contribute in a different way to the correlation coefficient. Analyses show symmetrical structure of 'r' on both sides of the equator over the African region, as data include mostly land region on both side of equator. Data represent positive correlation (r 0.5) over 15°-20° latitudes on either side of the equator over the African region, suggesting strong hold of the inter-seasonal variation of solar diabatic heating influence over the tropic of Cancer and tropic of Capricorn. On the other hand, there is a contrast behaviour over the Indian region, 'r' is nearly negative ( - 1.0) each year in the southern hemisphere (SH) and positive ( 0.4) in the northern hemisphere (NH) with a maxima near tropic of Cancer. Western Pacific region is found to display a linear increase in 'r' from negative ( - 1.0) in SH to positive ( 0.8) in NH. In general, 'r' (positive) maximizes over the land region around 15°-20° latitudes, suggesting a control of in phase inter-seasonal solar heating on the coupling of boundary layer/lower troposphere and CPT region, whereas it turns negative over water body. Analyses suggest that variabilities in CPT over different regions of globe show significant inter-seasonal association with the lower

  2. Inter-Annual Variability Of Rainfall In Some States Of Southern Nigeria

    Directory of Open Access Journals (Sweden)

    Egor

    2015-08-01

    Full Text Available Abstract The study inter-annual variability of rainfall in some states in Southern Nigeria focuses on analyzing the trends and fluctuations in annual rainfall over six states in Southern Nigeria covering a period of 1972 2012. In order to ascertain the variabilitys and to model the annual rainfall for future prediction to enhance policy implementation the quantitative and descriptive analysis techniques was employed. The rainfall series were analyzed for fluctuations using Standardized Anomaly Index SAI whereas the trends were examined using Statistical Package for Social Science Software SPSS 17.0. At 95 percent confidence level observations in the stations may be signals that the wetter period dominates the drier periods in this study. Each of the series contains two distinct periods when the rainfall anomalies negative and positive of a particular type were most significant. The period where the annual rainfall is above one standard deviation from the mean annual rainfall is considered Wet and the period below one standard deviation from the mean annual rainfall is considered Dry for each station. The results of the linear trend lines revealed an increase in rainfall supply over the period of study especially of recent. The annual rate of increase in rainfall over the period of investigation 1972 - 2012 were 15.21mmyear for Calabar 2.18mmyear for Port Harcourt 22.23mmyear for Owerri 3.25mmyear for Benin City 5.08mmyear for Enugu and 16.29mmyear for Uyo respectively. The variability in amount of annual rainfall revealed that in 2012 Calabar received the highest amount of rainfall of about 4062.70mm and the least value of 2099.4mm in 1973. In Porthacourt the highest amount of rainfall occurred in 1993 with a value of 3911.70mm and the least value in 1983 with a value of 1816.4mm. Owerri recorded the highest amount of rainfall of about 3064.0mm in 2011 and the least value occurred in 1986 with a value of 1228.4mm. In 1976 Benin received the

  3. Calibration through on-line monitoring of instruments channels

    International Nuclear Information System (INIS)

    James, R.W.

    1996-01-01

    Plant technical specifications require periodic calibration of instrument channels, and this has traditionally meant calibration at fixed time intervals for nearly all instruments. Experience has shown that unnecessarily frequent calibrations reduce channel availability and reliability, impact outage durations, and increase maintenance costs. An alternative approach to satisfying existing requirements for periodic calibration consists of on-line monitoring and quantitative comparison of instrument channels during operation to identify instrument degradation and failure. A Utility Working Group has been formed by EPRI to support the technical activities necessary to achieve generic NRC acceptance of on-line monitoring of redundant instrument channels as a basis for determining when to perform calibrations. A topical report proposing NRC acceptance of this approach was submitted in August 1995, and the Working Group is currently resolving NRC technical questions. This paper describes the proposed approach and the current status of the topical report with regard to NRC review. While these activities will not preclude utilities from continuing to use existing calibration approaches, successful acceptance of this performance-based approach will allow utilities to substantially reduce the number of calibrations which are performed. Concurrent benefits will include reduced I ampersand C impact on outage durations and improved sensitivity to instrument channel performance

  4. Inter-Annual Variability in Blue Whale Distribution off Southern Sri Lanka between 2011 and 2012

    Directory of Open Access Journals (Sweden)

    Asha de Vos

    2014-07-01

    Full Text Available Blue whale (Balaenoptera musculus movements are often driven by the availability of their prey in space and time. While globally blue whale populations undertake long-range migrations between feeding and breeding grounds, those in the northern Indian Ocean remain in low latitude waters throughout the year with the implication that the productivity of these waters is sufficient to support their energy needs. A part of this population remains around Sri Lanka where they are usually recorded close to the southern coast during the Northeast Monsoon. To investigate inter-annual variability in sighting locations, we conducted systematic Conductivity-Temperature-Depth (CTD and visual surveys between January–March 2011 and January–March 2012. In 2011, there was a notable decrease in inshore sightings compared to 2009 and 2012 (p < 0.001. CTD data revealed that in 2011 there was increased freshwater in the upper water column accompanied by deeper upwelling than in 2012. We hypothesise that anomalous rainfall, along with higher turbidity resulting from river discharge, affected the productivity of the inshore waters and caused a shift in blue whale prey and, consequently, the distribution of the whales themselves. An understanding of how predators and their prey respond to environmental variability is important for predicting how these species will respond to long-term changes. This is especially important given the rapid temperature increases predicted for the semi-enclosed northern Indian Ocean.

  5. Effect of inter-annual variability in pasture growth and irrigation response on farm productivity and profitability based on biophysical and farm systems modelling.

    Science.gov (United States)

    Vogeler, Iris; Mackay, Alec; Vibart, Ronaldo; Rendel, John; Beautrais, Josef; Dennis, Samuel

    2016-09-15

    Farm system and nutrient budget models are increasingly being used in analysis to inform on farm decision making and evaluate land use policy options at regional scales. These analyses are generally based on the use of average annual pasture yields. In New Zealand (NZ), like in many countries, there is considerable inter-annual variation in pasture growth rates, due to climate. In this study a modelling approach was used to (i) include inter-annual variability as an integral part of the analysis and (ii) test the approach in an economic analysis of irrigation in a case study within the Hawkes Bay Region of New Zealand. The Agricultural Production Systems Simulator (APSIM) was used to generate pasture dry matter yields (DMY) for 20 different years and under both dryland and irrigation. The generated DMY were linked to outputs from farm-scale modelling for both Sheep and Beef Systems (Farmaxx Pro) and Dairy Systems (Farmax® Dairy Pro) to calculate farm production over 20 different years. Variation in DMY and associated livestock production due to inter-annual variation in climate was large, with a coefficient of variations up to 20%. Irrigation decreased this inter-annual variation. On average irrigation, with unlimited available water, increased income by $831 to 1195/ha, but when irrigation was limited to 250mm/ha/year income only increased by $525 to 883/ha. Using pasture responses in individual years to capturing the inter-annual variation, rather than the pasture response averaged over 20years resulted in lower financial benefits. In the case study income from irrigation based on an average year were 10 to >20% higher compared with those obtained from individual years. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Characterization of regional left ventricular function in nonhuman primates using magnetic resonance imaging biomarkers: a test-retest repeatability and inter-subject variability study.

    Directory of Open Access Journals (Sweden)

    Smita Sampath

    Full Text Available Pre-clinical animal models are important to study the fundamental biological and functional mechanisms involved in the longitudinal evolution of heart failure (HF. Particularly, large animal models, like nonhuman primates (NHPs, that possess greater physiological, biochemical, and phylogenetic similarity to humans are gaining interest. To assess the translatability of these models into human diseases, imaging biomarkers play a significant role in non-invasive phenotyping, prediction of downstream remodeling, and evaluation of novel experimental therapeutics. This paper sheds insight into NHP cardiac function through the quantification of magnetic resonance (MR imaging biomarkers that comprehensively characterize the spatiotemporal dynamics of left ventricular (LV systolic pumping and LV diastolic relaxation. MR tagging and phase contrast (PC imaging were used to quantify NHP cardiac strain and flow. Temporal inter-relationships between rotational mechanics, myocardial strain and LV chamber flow are presented, and functional biomarkers are evaluated through test-retest repeatability and inter subject variability analyses. The temporal trends observed in strain and flow was similar to published data in humans. Our results indicate a dominant dimension based pumping during early systole, followed by a torsion dominant pumping action during late systole. Early diastole is characterized by close to 65% of untwist, the remainder of which likely contributes to efficient filling during atrial kick. Our data reveal that moderate to good intra-subject repeatability was observed for peak strain, strain-rates, E/circumferential strain-rate (CSR ratio, E/longitudinal strain-rate (LSR ratio, and deceleration time. The inter-subject variability was high for strain dyssynchrony, diastolic strain-rates, peak torsion and peak untwist rate. We have successfully characterized cardiac function in NHPs using MR imaging. Peak strain, average systolic strain

  7. Improving inter-observer variability in the evaluation of ultrasonographic features of polycystic ovaries

    Directory of Open Access Journals (Sweden)

    Leswick David A

    2008-07-01

    Full Text Available Abstract Background We recently reported poor inter-observer agreement in identifying and quantifying individual ultrasonographic features of polycystic ovaries. Our objective was to determine the effect of a training workshop on reducing inter-observer variation in the ultrasonographic evaluation of polycystic ovaries. Methods Transvaginal ultrasound recordings from thirty women with polycystic ovary syndrome (PCOS were evaluated by three radiologists and three reproductive endocrinologists both before and after an ultrasound workshop. The following endpoints were assessed: 1 follicle number per ovary (FNPO, 2 follicle number per single cross-section (FNPS, 3 largest follicle diameter, 4 ovarian volume, 5 follicle distribution pattern and 6 presence of a corpus luteum (CL. Lin's concordance correlation coefficients (rho and kappa statistics for multiple raters (kappa were used to assess level of inter-observer agreement (>0.80 good, 0.60 – 0.80 moderate/fair, Results Following the workshop, inter-observer agreement improved for the evaluation of FNPS (rho = 0.70, delta rho = +0.11, largest follicle diameter (rho = 0.77, delta rho = +0.10, ovarian volume (rho = 0.84, delta rho = +0.12, follicle distribution pattern (kappa = 0.80, delta kappa = +0.21 and presence of a CL (kappa = 0.87, delta kappa = +0.05. No improvement was evident for FNPO (rho = 0.54, delta rho = -0.01. Both radiologists and reproductive endocrinologists demonstrated improvement in scores (p Conclusion Reliability in evaluating ultrasonographic features of polycystic ovaries can be significantly improved following participation in a training workshop. If ultrasonographic evidence of polycystic ovaries is to be used as an objective measure in the diagnosis of PCOS, then standardized training modules should be implemented to unify the approach to evaluating polycystic ovarian morphology.

  8. A technical study of alloy compositions of "brass" wind musical instruments (1651-1867) utilizing non-destructive X-ray fluorescence

    Science.gov (United States)

    Bacon, Alice Louise

    This thesis represents a new interdisciplinary approach to the conservation, care and curatorial study of 'brass' wind musical instruments. It attempts to combine metallurgical, chronological and historical aspects for a selection of instruments. The research consists of the systematic study of seventy-seven musical instruments, by known makers, using standardised non-destructive energy dispersive x-ray fluorescence (XRF). Such compositional data are virtually non-existent for historical 'brass' instruments in Britain and what few technical data that do exist are sporadic in quantity and quality. The development of brass instruments is interwoven with the history of brass making, but because there are a limited number of appropriate examples such links can be difficult to identify. This thesis describes the development of brass production from the cementation process to the commercial production of zinc and modern brass. Its relationship to the musical instrument industry in Britain is linked with historical evidence. It will be shown that innovation and known historical metallurgical achievements are reflected in the compositional changes of the alloys used for musical instruments. This thesis focuses on specific named brass wind musical instrument makers. This thesis sets out to investigate the extent to which a single analytical technique such as non-destructive analysis utilising XRF could be useful in the curatorial and conservation care of musical instruments. The results of the analyses revealed new aspects to the use of metals for making musical instruments. They give new information on approximate alloy compositions and, in particular, the results have shown that in the seventeenth-century in England, a ternary alloy of copper/tin/zinc was used, and that it was, perhaps, only superseded by brass (copper/zinc alloy) in the eighteenth century. It has been possible to arrange the results into a chronology of alloys particularly reflecting the change from the

  9. Inter-Korean military confidence building after 2003.

    Energy Technology Data Exchange (ETDEWEB)

    Tae-woo, Kim (Korea Institute for Defense Analyses, Seoul, Republic of Korea); Littlefield, Adriane C.; Vannoni, Michael Geoffrey; Sang-beom, Kim (Korea Institute for Defense Analyses, Seoul, Republic of Korea); Koelm, Jennifer Gay; Olsen, John Norman; Myong-jin, Kim (Korea Institute for Defense Analyses, Seoul, Republic of Korea); Sung-tack, Shin (Korea Institute for Defense Analyses, Seoul, Republic of Korea)

    2003-08-01

    Tensions on the Korean Peninsula remain high despite a long-term strategy by South Korea to increase inter-Korean exchanges in economics, culture, sports, and other topics. This is because the process of reconciliation has rarely extended to military and security topics and those initiatives that were negotiated have been ineffective. Bilateral interactions must include actions to reduce threats and improve confidence associated with conventional military forces (land, sea, and air) as well as nuclear, chemical, and biological activities that are applicable to developing and producing weapons of mass destruction (WMD). The purpose of this project is to develop concepts for inter-Korean confidence building measures (CBMs) for military and WMD topics that South Korea could propose to the North when conditions are right. This report describes the historical and policy context for developing security-related CBMs and presents an array of bilateral options for conventional military and WMD topics within a consistent framework. The conceptual CBMs address two scenarios: (1) improved relations where construction of a peace regime becomes a full agenda item in inter-Korean dialogue, and (2) continued tense inter-Korean relations. Some measures could be proposed in the short term under current conditions, others might be implemented in a series of steps, while some require a higher level of cooperation than currently exists. To support decision making by political leaders, this research focuses on strategies and policy options and does not include technical details.

  10. Instrumentation a reader

    CERN Document Server

    Pope, P

    1990-01-01

    This book contains a selection of papers and articles in instrumentation previously pub­ lished in technical periodicals and journals of learned societies. Our selection has been made to illustrate aspects of current practice and applications of instrumentation. The book does not attempt to be encyclopaedic in its coverage of the subject, but to provide some examples of general transduction techniques, of the sensing of particular measurands, of components of instrumentation systems and of instrumentation practice in two very different environments, the food industry and the nuclear power industry. We have made the selection particularly to provide papers appropriate to the study of the Open University course T292 Instrumentation. The papers have been chosen so that the book covers a wide spectrum of instrumentation techniques. Because of this, the book should be of value not only to students of instrumen­ tation, but also to practising engineers and scientists wishing to glean ideas from areas of instrumen...

  11. 32 CFR 644.411 - Form of inter-agency transfer instrument.

    Science.gov (United States)

    2010-07-01

    ... Government's title and easements and other rights in the property granted by the Government will be stated... included in the instrument. (1) Effective date of transfer (where right-of-entry has been granted or... information for a full and complete understanding of the proposed transfer action, including an appraisal when...

  12. Inter-organizational Collaboration: Product, Knowledge and Risk

    Directory of Open Access Journals (Sweden)

    Norbert Jastroch

    2011-10-01

    Full Text Available Inter-organizational collaboration is no longer entirely a free choice, but is close to a necessity imposed by economic, technical, and knowledge-related concerns. A deep understanding of collaboration will assist in making intelligent decisions on entering, operating, and evaluating collaborative ventures. The nature of the partners—industrial corporations, consultants, academic institutions and others—and the collaborative structure are important, but so too is the nature of the product. We consider its effects in the collaborative domain on knowledge, intellectual property, and catastrophic risk.

  13. Sustainability inter-linkages in reporting vindeicated: a study of European companies

    NARCIS (Netherlands)

    Lozano, R.

    2013-01-01

    Recently, there has been a rapid growth in company sustainability reporting, as well as an improvement in quality of reports. A number of guidelines have been instrumental in this process; however, they still do not consider the importance of the inter-linkages and synergies among the different

  14. Factors associated to performance efficacy of technical-tactical actions in volleyball

    Directory of Open Access Journals (Sweden)

    William das Neves Salles

    2017-05-01

    Full Text Available DOI: http://dx.doi.org/10.5007/1980-0037.2017v19n1p74   The aim of the study was to investigate the factors associated to performance efficacy of technical-tactical actions in volleyball. Based on the protocol of the Instrument for Technical and Tactical Performance Assessment in Volleyball (IAD-VB, 44.025 match actions performed by male and female athletes from u-15, u-16 and u-17 finalist teams of the 2010 Santa Catarina Volleyball Championship in Brazil were observed. Data were analyzed on SPPS 21 software using the logistic regression technique, adopting 5% significance level for the interpretation of results. Adjusted model explained 51.40% efficacy variance, and the factors associated with this variable were decision making, adjustment, efficiency, and competition level.

  15. Nuclear incident monitor criticality alarm instrument for the Savannah River Site: Technical manual

    International Nuclear Information System (INIS)

    Jenkins, J.B.

    1996-01-01

    The Savannah River Site is a Department of Energy facility. The facility stores, processes, and works with fissionable material at a number of locations. Technical standards and US Department of Energy orders, require these locations to be monitored by criticality alarm systems under certain circumstances. The Savannah River Site calls such instruments Nuclear Incident Monitors or NIMs. The Sole purpose of the Nuclear Incident Monitor is to provide an immediate evacuation signal in the case of an accidental criticality in order to minimize personnel exposure to radiation. The new unit is the third generation Nuclear Incident Monitor at the Savannah River Site. The second generation unit was developed in 1979. It was designed to eliminate vacuum-tube circuits, and was the first solid state NIM at SRS. The major design objectives of the second generation NIM were to improve reliability and reduce maintenance costs. Ten prototype units have been built and tested. This report describes the design of the new NIM and the testing that took place to verify its acceptability

  16. Technical specifications of variable speed motors for negative pressure control in hot cell area

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seon Duk; Bang, H. S.; Cho, W. K

    2002-01-01

    Hot cells are the facilities for handling the high radioactive materials and various R and D activities are performed using hot cells. Therefore the control of air flow in hot cell area is very important technology and it is started with the variable speed motor(VSM) controlling the air handling system in that area. This report describes various technical aspects of VS motors and will be useful for understanding the practical technologies of VS motors and also for optimization of the negative pressure controls in hot cell area.

  17. Climate drives inter-annual variability in probability of high severity fire occurrence in the western United States

    Science.gov (United States)

    Keyser, Alisa; Westerling, Anthony LeRoy

    2017-05-01

    A long history of fire suppression in the western United States has significantly changed forest structure and ecological function, leading to increasingly uncharacteristic fires in terms of size and severity. Prior analyses of fire severity in California forests showed that time since last fire and fire weather conditions predicted fire severity very well, while a larger regional analysis showed that topography and climate were important predictors of high severity fire. There has not yet been a large-scale study that incorporates topography, vegetation and fire-year climate to determine regional scale high severity fire occurrence. We developed models to predict the probability of high severity fire occurrence for the western US. We predict high severity fire occurrence with some accuracy, and identify the relative importance of predictor classes in determining the probability of high severity fire. The inclusion of both vegetation and fire-year climate predictors was critical for model skill in identifying fires with high fractional fire severity. The inclusion of fire-year climate variables allows this model to forecast inter-annual variability in areas at future risk of high severity fire, beyond what slower-changing fuel conditions alone can accomplish. This allows for more targeted land management, including resource allocation for fuels reduction treatments to decrease the risk of high severity fire.

  18. Abnormalities of the airways and lung parenchyma in asthmatics: CT observations in 50 patients and inter- and intraobserver variability

    International Nuclear Information System (INIS)

    Grenier, P.; Mourey-Gerosa, I.; Benali, K.; Brauner, M.W.; Leung, A.N.; Lenoir, S..; Cordeau, M.P.; Mazoyer, B.

    1996-01-01

    The purpose of the study was to evaluate the CT abnormalities of airways and lung parenchyma in asthmatic patients and to assess inter- and intraobserver variability for these abnormalities. The CT scans of 50 asthmatic patients and 10 healthy volunteers were assessed independently by four independent chest radiologists who were masked with respect to the clinical informations. Bronchiectasis involving mostly subsegmental and destal bronchi was noted in 28.5% of the asthmatic subjects and none of the non-asthmatics. Bronchial wall thickening, small centrilobular opacities and decreased lung attenuation were observed in 82%, 21% and 31% of asthmatic patients respectively, compared with 7%, 5% and 7% of healthy subjects. The intra- and interobserver agreements for these four CT abnormalities were measured by the kappa statistic and ranged from 0.60 to 0.79 and from 0.40 to 0.64, respectively. It is concluded that asthmatic patients may exhibit bronchial wall thickening, bronchiectasis and morphological abnormalities suggestive of distal airways disease that can be assessed on CT scans with a clinically acceptable observer variability. (orig.)

  19. Direct concurrent comparison of multiple pediatric acute asthma scoring instruments.

    Science.gov (United States)

    Johnson, Michael D; Nkoy, Flory L; Sheng, Xiaoming; Greene, Tom; Stone, Bryan L; Garvin, Jennifer

    2017-09-01

    Appropriate delivery of Emergency Department (ED) treatment to children with acute asthma requires clinician assessment of acute asthma severity. Various clinical scoring instruments exist to standardize assessment of acute asthma severity in the ED, but their selection remains arbitrary due to few published direct comparisons of their properties. Our objective was to test the feasibility of directly comparing properties of multiple scoring instruments in a pediatric ED. Using a novel approach supported by a composite data collection form, clinicians categorized elements of five scoring instruments before and after initial treatment for 48 patients 2-18 years of age with acute asthma seen at the ED of a tertiary care pediatric hospital ED from August to December 2014. Scoring instruments were compared for inter-rater reliability between clinician types and their ability to predict hospitalization. Inter-rater reliability between clinician types was not different between instruments at any point and was lower (weighted kappa range 0.21-0.55) than values reported elsewhere. Predictive ability of most instruments for hospitalization was higher after treatment than before treatment (p < 0.05) and may vary between instruments after treatment (p = 0.054). We demonstrate the feasibility of comparing multiple clinical scoring instruments simultaneously in ED clinical practice. Scoring instruments had higher predictive ability for hospitalization after treatment than before treatment and may differ in their predictive ability after initial treatment. Definitive conclusions about the best instrument or meaningful comparison between instruments will require a study with a larger sample size.

  20. Description, evaluation and clinical decision making according to various fetal heart rate patterns. Inter-observer and regional variability

    DEFF Research Database (Denmark)

    Lidegaard, O; Bøttcher, L M; Weber, Tom

    1992-01-01

    departments, especially between departments far apart. It is concluded that we still need a scientific clarification of which specific heart rate changes are the best predictors of fetal stress. Artificial intelligence programs for interpreting fetal cardiotocograms and ECG signals constitute one promising......At 10 Danish obstetrical departments, 116 residents (42 senior and 74 junior) participated in a study to assess inter-observer and regional variability in the description and evaluation of and clinical decision regarding 11 fetal heart rate patterns. The 11 traces included normal as well...... as pathological patterns, and normal as well as clinically asphyxiated babies. Five antepartum and six intrapartum patterns were included. A total of 1,276 descriptions and evaluations were obtained. The degree of agreement in description of fetal heart rate changes was high regarding the baseline...

  1. Safety regulations concerning instrumentation and control systems for research reactors

    International Nuclear Information System (INIS)

    El-Shanshoury, A.I.

    2009-01-01

    A brief study on the safety and reliability issues related to instrumentation and control systems in nuclear reactor plants is performed. In response, technical and strategic issues are used to accomplish instrumentation and control systems safety. For technical issues there are ; systems aspects of digital I and C technology, software quality assurance, common-mode software, failure potential, safety and reliability assessment methods, and human factors and human machine interfaces. The strategic issues are the case-by-case licensing process and the adequacy of the technical infrastructure. The purpose of this work was to review the reliability of the safety systems related to these technical issues for research reactors

  2. Technical design issues for a field-portable supercritical fluid extractor

    Energy Technology Data Exchange (ETDEWEB)

    Wright, B.W.; Zemanian, T.S.; Robins, W.H.; Wright, C.W.

    1995-01-01

    Supercritical fluid extraction is gaining acceptance as an alternative sample preparation method for trace organic analysis. The development of SFE instrumentation optimized for field use requires taking several technical design issues including size and weight requirements, user-friendly operation, and technical performance capabilities into consideration. Parameters associated with a prototype SFE instrument under development for potential use in conducting on-site inspections of the Chemical Weapons Convention and its preliminary technical and operational performance are described.

  3. Association of Body Mass Index with Depression, Anxiety and Suicide-An Instrumental Variable Analysis of the HUNT Study.

    Directory of Open Access Journals (Sweden)

    Johan Håkon Bjørngaard

    Full Text Available While high body mass index is associated with an increased risk of depression and anxiety, cumulative evidence indicates that it is a protective factor for suicide. The associations from conventional observational studies of body mass index with mental health outcomes are likely to be influenced by reverse causality or confounding by ill-health. In the present study, we investigated the associations between offspring body mass index and parental anxiety, depression and suicide in order to avoid problems with reverse causality and confounding by ill-health.We used data from 32,457 mother-offspring and 27,753 father-offspring pairs from the Norwegian HUNT-study. Anxiety and depression were assessed using the Hospital Anxiety and Depression Scale and suicide death from national registers. Associations between offspring and own body mass index and symptoms of anxiety and depression and suicide mortality were estimated using logistic and Cox regression. Causal effect estimates were estimated with a two sample instrument variable approach using offspring body mass index as an instrument for parental body mass index.Both own and offspring body mass index were positively associated with depression, while the results did not indicate any substantial association between body mass index and anxiety. Although precision was low, suicide mortality was inversely associated with own body mass index and the results from the analysis using offspring body mass index supported these results. Adjusted odds ratios per standard deviation body mass index from the instrumental variable analysis were 1.22 (95% CI: 1.05, 1.43 for depression, 1.10 (95% CI: 0.95, 1.27 for anxiety, and the instrumental variable estimated hazard ratios for suicide was 0.69 (95% CI: 0.30, 1.63.The present study's results indicate that suicide mortality is inversely associated with body mass index. We also found support for a positive association between body mass index and depression, but not

  4. Technical evaluation of the electrical, instrumentation, and control design aspects of the low temperature overpressure protection system for the Yankee Rowe nuclear power plant

    International Nuclear Information System (INIS)

    Latorre, V.R.; Mayn, B.G.

    1979-08-01

    This report documents the technical evaluation of the electrical, instrumentation, and control design aspects for the low temperature overpressure protection system of the Yankee Rowe nuclear power plant. Design basis criteria used to evaluate the acceptability of the system included operator action, system testability, single failure criterion, and seismic Category I and IEEE Std-279-1971 criteria

  5. Technical evaluation of the electrical, instrumentation, and control design aspects of the low temperature overpressure protection system for the Maine Yankee nuclear power plant

    International Nuclear Information System (INIS)

    Latorre, V.R.; Mayn, B.G.

    1979-08-01

    This report documents the technical evaluation of the electrical, instrumentation, and control design aspects for the low temperature overpressure protection system of the Maine Yankee nuclear power plant. Design basis criteria used to evaluate the acceptability of the system included operator action, system testability, single failure criterion, and seismic Category I and IEEE Std-279-1971 criteria

  6. Seasonal and inter-annual temperature variability in the bottom waters over the Black Sea shelf

    Science.gov (United States)

    Shapiro, G. I.; Wobus, F.; Aleynik, D. L.

    2011-02-01

    convection events is well preserved over the following months in the deep sea, the signal of winter cooling in the Bottom Shelf Waters significantly reduces during the warm season. The time series of temperature in the BSW is highly correlated with the temperature of Cold Intermediate Waters in the deep sea thus indicating that the isopycnal exchanges with the deep sea are more important for inter-annual/inter-decadal variability of the BSW on the Western Black Sea shelf than winter convection on the shelf itself.

  7. Medizinbibliotheken: inter:disziplinär – inter:national –inter:aktiv

    Directory of Open Access Journals (Sweden)

    Bauer, Bruno

    2017-12-01

    Full Text Available The focus of the current issue 3/2017 of GMS Medizin – Bibliothek – Information is the annual conference 2017 of the German Medical Libraries Association in Vienna. The motto of the conference was “Medical Libraries: inter:disciplinary – inter:national – inter:active”. The authors in this issue are Bruno Bauer (Austrian Transition to Open Access 2017–2020, Beata Górczynska (Development and structure of Polish veterinary school system and its libraries, Katharina Heldt, Henriette Senst & Jessica Riedel (Salon on the institute’s history: outstanding artifacts. 28.01.2016 to 15.12.2016, Jutta Matrisciano, Martina Semmler-Schmetz & Saskia Rohmer (Advice – From info snack to special menu: Solutions of the MedMA-Bib, Stefan Nortmann (The ‘Ersti-Café’ of the Medical Branch Library Münster, Sandra Rümmele (Toolbox: The new teaching library project of the Central Medical Library of the University Medical Center Hamburg-Eppendorf, Eva Seidlmayer & Christoph Poley (One Health – Transdisciplinarity at ZB MED and Heike Andermann (“Medical Libraries: inter:disciplinary – inter:national – inter:active”. Annual Meeting of the German Medical Library Association (AGMB, September 25 to 27, 2017 in Vienna. Furthermore this focus issue features articles from Stefan Grün & Christoph Poley (Statistical evaluation of semantic entities from metadata and full text on German Medical Science corpora and Iris Reimann (German MLA News; Competition of the German MLA Pioneer projects in medical libraries 2017: Introduction of the winners; Competition of the German MLA (AGMB Pioneer projects in medical libraries 2018 – Announcement.

  8. Evaluation of effects of selected factors on inter-vertebral fusion-a simulation study.

    Science.gov (United States)

    Wang, Xiaobo; Dumas, Geneviève A

    2005-04-01

    This study simulated the effects of inter-vertebral disc degeneration and bone density distribution on the structural stiffness and strength provided by inter-vertebral fusion. Based on the original and redistributed bone density distributions, the effects of selected factors, including contact area between device/graft and vertebral endplates, endplate conditions, and bone growth capacity were evaluated using a factorial design of experiment. The simulation results suggested that the degeneration of inter-vertebral disc significantly affected the bone density and density distribution in adjacent vertebrae. The mechanical strength immediately after instrumentation is the worst case of device/graft subsidence. After that procedure, bone will adapt itself to the changed loading conditions and therefore reduce the risk of subsidence. A deficiency in structural stiffness immediately after instrumentation could be the "worst-case scenario" depending on the combinations of selected factors. The simulation results demonstrated that the contact area and initial bone density distribution should be considered jointly while estimating the risk of device/graft subsidence. The endplate condition is a secondary factor on the subsidence risk, compared with the contact area and initial bone density distribution.

  9. MANU. Instrumentation of Buffer Demo. Preliminary Study

    International Nuclear Information System (INIS)

    Laaksonen, R.

    2010-01-01

    The purpose of this work is to describe feasible measuring and monitoring alternatives which can be used, if needed, in medium to full scale nuclear waste repository deposition hole mock-up tests. The focus of the work was to determine what variables can actually be measured, how to achieve the measurements and what kind of demands comes from the modelling, scientific, and technical points of view. This project includes a review of the previous waste repository mock-up tests carried out in several European countries such as Belgium, Czech Republic, Spain and Sweden. Also information was gathered by interviewing domestic and foreign scientists specialized in the fields of measurement instrumentation and related in-situ and laboratory work. On the basis of this review, recommendations were developed for the necessary actions needed to be done from the instrumentation point of view for future tests. It is possible to measure and monitor the processes going on in a deposition hole in-situ conditions. The data received during a test in real repository conditions enables to follow the processes and to verify the hypothesis made on the behaviour of various components of the repository: buffer, canister, rock and backfill. Because full scale testing is expensive, the objectives and hypothesis must be carefully set and the test itself with its instrumentation must serve very specific objectives. The main purpose of mock-up tests is to verify that the conditions surrounding the canister are according to the design requirements. A whole mock-up test and demonstration process requires a lot of time and effort. The instrumentation part of the work must also start at early stages to ensure that the instrumentation itself will not become bottlenecked nor suffer from low quality solutions. The planning of the instrumentation work could be done in collaboration with foreign scientists which have participated to previous instrumentation projects. (orig.)

  10. Sandia Laboratories technical capabilities: instrumentation and data systems

    International Nuclear Information System (INIS)

    Lundergain, C.D.; Mead, P.L.

    1975-12-01

    This report characterizes the instrumentation and data systems capabilities at Sandia Laboratories. Selected applications of these capabilities are presented to illustrate the extent to which they can be applied in research and development programs

  11. Risk management: integration of social and technical risk variables into safety assessments of LWR'S

    International Nuclear Information System (INIS)

    Turnage, J.J.; Husseiny, A.A.

    1980-01-01

    A risk management methodology is developed here to formalize the acceptability levels of commercial LWR power plants via the estimation of risk levels acceptable to the public and the integration of such estimates into risk-benefit analysis. Utility theory is used for developing preference models based on value trade-offs among multiple objectives and uncertainties about the impact of alternatives. The method involves reducing the various variables affecting safety acceptability decisions to a single function that provides a metric for acceptability levels. The function accomondates for technical criteria related to design and licensing decisions, as well as public reactions to certain choices

  12. The interRAI Acute Care instrument incorporated in an eHealth system for standardized and web-based geriatric assessment: strengths, weaknesses, opportunities and threats in the acute hospital setting

    Science.gov (United States)

    2013-01-01

    Background The interRAI Acute Care instrument is a multidimensional geriatric assessment system intended to determine a hospitalized older persons’ medical, psychosocial and functional capacity and needs. Its objective is to develop an overall plan for treatment and long-term follow-up based on a common set of standardized items that can be used in various care settings. A Belgian web-based software system (BelRAI-software) was developed to enable clinicians to interpret the output and to communicate the patients’ data across wards and care organizations. The purpose of the study is to evaluate the (dis)advantages of the implementation of the interRAI Acute Care instrument as a comprehensive geriatric assessment instrument in an acute hospital context. Methods In a cross-sectional multicenter study on four geriatric wards in three acute hospitals, trained clinical staff (nurses, occupational therapists, social workers, and geriatricians) assessed 410 inpatients in routine clinical practice. The BelRAI-system was evaluated by focus groups, observations, and questionnaires. The Strengths, Weaknesses, Opportunities and Threats were mapped (SWOT-analysis) and validated by the participants. Results The primary strengths of the BelRAI-system were a structured overview of the patients’ condition early after admission and the promotion of multidisciplinary assessment. Our study was a first attempt to transfer standardized data between home care organizations, nursing homes and hospitals and a way to centralize medical, allied health professionals and nursing data. With the BelRAI-software, privacy of data is guaranteed. Weaknesses are the time-consuming character of the process and the overlap with other assessment instruments or (electronic) registration forms. There is room for improving the user-friendliness and the efficiency of the software, which needs hospital-specific adaptations. Opportunities are a timely and systematic problem detection and continuity of

  13. Appropriability, Technological Opportunity, Market Demand, and Technical Change - Empirical Evidence from Switzerland

    OpenAIRE

    Harabi, Najib

    1992-01-01

    The purpose of this paper is to analyze both theoretically and empirically those factors which underlay the - empirically observable - inter-industry differences in technical progress. At the theoretical level economists agree more and more that technical progress can be explained at the industry level by the following three factors: (1) the technological opportunities, (2) the appropriability conditions, meaning the ability to capture and protect the results of technical innovations and (3) ...

  14. Technical support non-SLB(GCDF)

    International Nuclear Information System (INIS)

    DePoorter, G.L.; Burton, B.W.

    1982-01-01

    The Los Alamos National Laboratory is providing technical support for the Greater Confinement Demonstration Facility (GCDF) at the Nevada Test Site. This technical support consists of computer modeling of the GCDF, design and emplacement of a Shallow Test Plot at NTS, and instrument testing at Los Alamos. Results to date on the computer modeling and the Shallow Test Plot are described

  15. Radiometric well logging instruments

    International Nuclear Information System (INIS)

    Davydov, A.V.

    1975-01-01

    The technical properties of well instruments for radioactive logging used in the radiometric logging complexes PKS-1000-1 (''Sond-1'') and PRKS-2 (''Vitok-2'') are described. The main features of the electric circuit of the measuring channels are given

  16. In-Pile Testing and Instrumentation for Development of Generation-IV Fuels and Materials. Proceedings of a Technical Meeting

    International Nuclear Information System (INIS)

    2013-12-01

    For many years, the increase in efficiency in the production of nuclear electricity has been an economic challenge in many countries which have developed this kind of energy. The increase in fuel burnup and fuel residence time leads to a reduction in the volume of fresh fuel loaded and spent fuel discharged, respectively. More demanding nuclear fuel cycle parameters are combined with a need to operate nuclear power plants with maximal availability and load factors, in load-follow mode and with longer fuel cycles. In meeting these requirements, fuel has to operate in a demanding environment of high radiation fields, high temperatures, high mechanical stresses and high coolant flow. Requirements of increased fuel reliability and minimal fuel failures also remain in force. Under such circumstances, continuous development of more radiation resistant fuel materials, especially advanced cladding, careful and incremental examinations, and improved understanding and modelling of high burnup fuel behaviour are required. Following a recommendation of the IAEA Technical Working Group on Fuel Performance and Technology, the Technical Meeting on In-pile Testing and Instrumentation for Development of Generation-IV Fuels and Materials was held in Halden, Norway, on 21-24 August 2012. The purpose of the meeting was to review the current status and the progress in methods and technologies used for the in-pile testing of nuclear fuel achieved since the previous IAEA meeting on In-core Instrumentation and Reactor Core Assessment, also held in Halden in 2007. Emphasis was placed on advanced techniques applied for the understanding of high burnup fuel behaviour of water cooled power reactors that represent the vast majority of the current nuclear reactor fleet. However, the meeting also included papers and discussion on testing techniques applied or developed specifically for new fuel and structural materials considered for Generation-IV systems. The meeting was attended by 43

  17. Inter- and intra-observer variability of time-lapse annotations

    DEFF Research Database (Denmark)

    Sundvall, Linda; Ingerslev, Hans Jakob; Breth Knudsen, Ulla

    2013-01-01

    . This provides the basis for further investigation of embryo assessment and selection by time-lapse imaging in prospective trials. Study funding/competing interest(s): Research at the Fertility Clinic was funded by an unrestricted grant from Ferring and MSD. The authors have no competing interests to declare.......Study question: How consistent is the time-lapse annotation of dynamic and static morphologic parameters of embryo development, within and between observers? Summary answer: The assessment of dynamic parameters is characterized by almost perfect agreement within and between observers. What is known...... already: The commonly employed method used to assess embryos in IVF treatments is based on static evaluation of morphology in a microscope, but this is limited by substantial intra- and inter-observer variation. Time-lapse imaging has been proposed as a method to refine embryo selection by adding new...

  18. Improving the non-technical skills of hospital medical emergency teams: The Team Emergency Assessment Measure (TEAM™).

    Science.gov (United States)

    Cant, Robyn P; Porter, Joanne E; Cooper, Simon J; Roberts, Kate; Wilson, Ian; Gartside, Christopher

    2016-12-01

    This prospective descriptive study aimed to test the validity and feasibility of the Team Emergency Assessment Measure (TEAM™) for assessing real-world medical emergency teams' non-technical skills. Second, the present study aimed to explore the instrument's contribution to practice regarding teamwork and learning outcomes. Registered nurses (RNs) and medical staff (n = 104) in two hospital EDs in rural Victoria, Australia, participated. Over a 10 month period, the (TEAM™) instrument was completed by multiple clinicians at medical emergency episodes. In 80 real-world medical emergency team resuscitation episodes (283 clinician assessments), non-technical skills ratings averaged 89% per episode (39 of a possible 44 points). Twenty-one episodes were rated in the lowest quartile (i.e. ≤37 points out of 44). Ratings differed by discipline, with significantly higher scores given by medical raters (mean: 41.1 ± 4.4) than RNs (38.7 ± 5.4) (P = 0.001). This difference occurred in the Leadership domain. The tool was reliable with Cronbach's alpha 0.78, high uni-dimensional validity and mean inter-item correlation of 0.45. Concurrent validity was confirmed by strong correlation between TEAM™ score and the awarded Global Rating (P technical skills of medical emergency teams are known to often be suboptimal; however, average ratings of 89% were achieved in this real-world study. TEAM™ is a valid, reliable and easy to use tool, for both training and clinical settings, with benefits for team performance when used as an assessment and/or debriefing tool. © 2016 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  19. Towards automated processing of the right of access in inter-organizational Web Service compositions

    DEFF Research Database (Denmark)

    Herkenhöner, Ralph; De Meer, Hermann; Jensen, Meiko

    2010-01-01

    with trade secret protection. In this paper, we present an automated architecture to enable exercising the right of access in the domain of inter-organizational business processes based on Web Services technology. Deriving its requirements from the legal, economical, and technical obligations, we show...

  20. Inter-laboratory agreement on embryo classification and clinical decision: Conventional morphological assessment vs. time lapse.

    Science.gov (United States)

    Martínez-Granados, Luis; Serrano, María; González-Utor, Antonio; Ortíz, Nereyda; Badajoz, Vicente; Olaya, Enrique; Prados, Nicolás; Boada, Montse; Castilla, Jose A

    2017-01-01

    The aim of this study is to determine inter-laboratory variability on embryo assessment using time-lapse platform and conventional morphological assessment. This study compares the data obtained from a pilot study of external quality control (EQC) of time lapse, performed in 2014, with the classical EQC of the Spanish Society for the Study of Reproductive Biology (ASEBIR) performed in 2013 and 2014. In total, 24 laboratories (8 using EmbryoScope™, 15 using Primo Vision™ and one with both platforms) took part in the pilot study. The clinics that used EmbryoScope™ analysed 31 embryos and those using Primo Vision™ analysed 35. The classical EQC was implemented by 39 clinics, based on an analysis of 25 embryos per year. Both groups were required to evaluate various qualitative morphological variables (cell fragmentation, the presence of vacuoles, blastomere asymmetry and multinucleation), to classify the embryos in accordance with ASEBIR criteria and to stipulate the clinical decision taken. In the EQC time-lapse pilot study, the groups were asked to determine, as well as the above characteristics, the embryo development times, the number, opposition and size of pronuclei, the direct division of 1 into 3 cells and/or of 3 into 5 cells and false divisions. The degree of agreement was determined by calculating the intra-class correlation coefficients and the coefficient of variation for the quantitative variables and the Gwet index for the qualitative variables. For both EmbryoScope™ and Primo Vision™, two periods of greater inter-laboratory variability were observed in the times of embryo development events. One peak of variability was recorded among the laboratories addressing the first embryo events (extrusion of the second polar body and the appearance of pronuclei); the second peak took place between the times corresponding to the 8-cell and morula stages. In most of the qualitative variables analysed regarding embryo development, there was almost

  1. Inter-laboratory agreement on embryo classification and clinical decision: Conventional morphological assessment vs. time lapse.

    Directory of Open Access Journals (Sweden)

    Luis Martínez-Granados

    Full Text Available The aim of this study is to determine inter-laboratory variability on embryo assessment using time-lapse platform and conventional morphological assessment. This study compares the data obtained from a pilot study of external quality control (EQC of time lapse, performed in 2014, with the classical EQC of the Spanish Society for the Study of Reproductive Biology (ASEBIR performed in 2013 and 2014. In total, 24 laboratories (8 using EmbryoScope™, 15 using Primo Vision™ and one with both platforms took part in the pilot study. The clinics that used EmbryoScope™ analysed 31 embryos and those using Primo Vision™ analysed 35. The classical EQC was implemented by 39 clinics, based on an analysis of 25 embryos per year. Both groups were required to evaluate various qualitative morphological variables (cell fragmentation, the presence of vacuoles, blastomere asymmetry and multinucleation, to classify the embryos in accordance with ASEBIR criteria and to stipulate the clinical decision taken. In the EQC time-lapse pilot study, the groups were asked to determine, as well as the above characteristics, the embryo development times, the number, opposition and size of pronuclei, the direct division of 1 into 3 cells and/or of 3 into 5 cells and false divisions. The degree of agreement was determined by calculating the intra-class correlation coefficients and the coefficient of variation for the quantitative variables and the Gwet index for the qualitative variables. For both EmbryoScope™ and Primo Vision™, two periods of greater inter-laboratory variability were observed in the times of embryo development events. One peak of variability was recorded among the laboratories addressing the first embryo events (extrusion of the second polar body and the appearance of pronuclei; the second peak took place between the times corresponding to the 8-cell and morula stages. In most of the qualitative variables analysed regarding embryo development, there

  2. 26 CFR 1.1275-5 - Variable rate debt instruments.

    Science.gov (United States)

    2010-04-01

    ... nonpublicly traded property. A debt instrument (other than a tax-exempt obligation) that would otherwise... variations in the cost of newly borrowed funds in the currency in which the debt instrument is denominated... on the yield of actively traded personal property (within the meaning of section 1092(d)(1)). (ii...

  3. Inter-annual rainfall variability in the eastern Antilles and coupling with the regional and intra-seasonal circulation

    Science.gov (United States)

    Jury, Mark R.

    2016-11-01

    Climate variability in the eastern Antilles island chain is analyzed via principal component analysis of high-resolution monthly rainfall in the period 1981-2013. The second mode reflecting higher rainfall in July-October season between Martinique and Grenada is the focus of this study. Higher rainfall corresponds with a weakened trade wind and boundary current along the southern edge of the Caribbean. This quells the coastal upwelling off Venezuela and builds the freshwater plume east of Trinidad. There is corresponding upper easterly wind flow that intensifies passing tropical waves. During a storm event over the Antilles on 4-5 October 2010, there was inflow from east of Guyana where low salinity and high sea temperatures enable surplus latent heat fluxes. A N-S convective rain band forms ˜500 km east of the cyclonic vortex. Many features at the weather timescale reflect the seasonal correlation and composite difference maps and El Nino Southern Oscillation (ENSO) modulation of oceanic inter-basin transfers.

  4. Technical evaluation of the electrical, instrumentation, and control design aspects of the low temperature overpressure protection system for the Salem nuclear power plant, Unit 1

    International Nuclear Information System (INIS)

    Laudenbach, D.H.

    1979-03-01

    The technical evaluation is presented for the electrical, instrumentation, and control design aspects of the low temperature overpressure protection system for the Salem nuclear power plant, Unit 1. Design basis criteria used to evaluate the acceptability of the system include operator action, system testability, single failure criterion, and seismic Category I and IEEE Std-279-1971 criteria

  5. Technical Performance as a Predictor of Clinical Outcomes in Laparoscopic Gastric Cancer Surgery.

    Science.gov (United States)

    Fecso, Andras B; Bhatti, Junaid A; Stotland, Peter K; Quereshy, Fayez A; Grantcharov, Teodor P

    2018-03-23

    The purpose of this study was to evaluate the relationship between technical performance and patient outcomes in laparoscopic gastric cancer surgery. Laparoscopic gastrectomy for cancer is an advanced procedure with high rate of postoperative morbidity and mortality. Many variables including patient, disease, and perioperative management factors have been shown to impact postoperative outcomes; however, the role of surgical performance is insufficiently investigated. A retrospective review was performed for all patients who had undergone laparoscopic gastrectomy for cancer at 3 teaching institutions between 2009 and 2015. Patients with available, unedited video-recording of their procedure were included in the study. Video files were rated for technical performance, using Objective Structured Assessments of Technical Skills (OSATS) and Generic Error Rating Tool instruments. The main outcome variable was major short-term complications. The effect of technical performance on patient outcomes was assessed using logistic regression analysis with backward selection strategy. Sixty-one patients with available video recordings were included in the study. The overall complication rate was 29.5%. The mean Charlson comorbidity index, type of procedure, and the global OSATS score were included in the final predictive model. Lower performance score (OSATS ≤29) remained an independent predictor for major short-term outcomes (odds ratio 6.49), while adjusting for comorbidities and type of procedure. Intraoperative technical performance predicts major short-term outcomes in laparoscopic gastrectomy for cancer. Ongoing assessment and enhancement of surgical skills using modern, evidence-based strategies might improve short-term patient outcomes. Future work should focus on developing and studying the effectiveness of such interventions in laparoscopic gastric cancer surgery.

  6. A neural network-based estimate of the seasonal to inter-annual variability of the Atlantic Ocean carbon sink

    DEFF Research Database (Denmark)

    Landschützer, P.; Gruber, N.; Bakker, D.C.E.

    2013-01-01

    The Atlantic Ocean is one of the most important sinks for atmospheric carbon dioxide (CO2), but this sink is known to vary substantially in time. Here we use surface ocean CO2 observations to estimate this sink and the temporal variability from 1998 to 2007 in the Atlantic Ocean. We benefit from ......, leading to a substantial trend toward a stronger CO2 sink for the entire South Atlantic (–0.14 Pg C yr–1 decade–1). The Atlantic carbon sink varies relatively little on inter-annual time-scales (±0.04 Pg C yr–1; 1σ)......The Atlantic Ocean is one of the most important sinks for atmospheric carbon dioxide (CO2), but this sink is known to vary substantially in time. Here we use surface ocean CO2 observations to estimate this sink and the temporal variability from 1998 to 2007 in the Atlantic Ocean. We benefit from (i...... poleward of 40° N, but many other parts of the North Atlantic increased more slowly, resulting in a barely changing Atlantic carbon sink north of the equator (–0.007 Pg C yr–1 decade–1). Surface ocean pCO2 was also increasing less than that of the atmosphere over most of the Atlantic south of the equator...

  7. Annual to Inter-Decadal Variability in Surface Air Temperature Along ...

    African Journals Online (AJOL)

    instrumental sea surface temperature (SST) and. East African rainfall ... accelerated rise in minimum temperatures. The objectives of the ... Altitude above sea level (m) Urban/Exposed. Tanga. 05.05°S ...... Environmental Report, South Florida.

  8. A Method for Estimating BeiDou Inter-frequency Satellite Clock Bias

    Directory of Open Access Journals (Sweden)

    LI Haojun

    2016-02-01

    Full Text Available A new method for estimating the BeiDou inter-frequency satellite clock bias is proposed, considering the shortage of the current methods. The constant and variable parts of the inter-frequency satellite clock bias are considered in the new method. The data from 10 observation stations are processed to validate the new method. The characterizations of the BeiDou inter-frequency satellite clock bias are also analyzed using the computed results. The results of the BeiDou inter-frequency satellite clock bias indicate that it is stable in the short term. The estimated BeiDou inter-frequency satellite clock bias results are molded. The model results show that the 10 parameters of model for each satellite can express the BeiDou inter-frequency satellite clock bias well and the accuracy reaches cm level. When the model parameters of the first day are used to compute the BeiDou inter-frequency satellite clock bias of the second day, the accuracy also reaches cm level. Based on the stability and modeling, a strategy for the BeiDou satellite clock service is presented to provide the reference of our BeiDou.

  9. Radiographic technical quality of root canal treatment performed ex vivo by dental students at Valencia University Medical and Dental School, Spain

    Science.gov (United States)

    Faus-Matoses, Vicente; Alegre-Domingo, Teresa; Faus-Llácer, Vicente J.

    2014-01-01

    Objectives: To evaluate radiographically the quality of root canal fillings and compare manual and rotary preparation performed on extracted teeth by undergraduate dental students. Study Design: A total of 561 premolars and molars extracted teeth were prepared using nickel-titanium rotary files or manual instrumentation and filled with gutta-percha using a cold lateral condensation technique, by 4th grade undergraduate students. Periapical radiographs were used to assess the technical quality of the root canal filling, evaluating three variables: length, density and taper. These data were recorded, scored and used to study the “technical success rate” and the “overall score”. The length of each root canal filling was classified as acceptable, short and overfilled, based on their relationship with the radiographic apex. Density and taper of filling were evaluated based on the presence of voids and the uniform tapering of the filling, respectively. Statistical analysis was used to evaluate the quality of root canal treatment, considering p rotary instruments (52% against 28% with a manual one, p rotary instrumentation. Key words:Dental education, endodontics, rotary instrumentation, radiographs, root canal treatment, undergraduate students. PMID:24121911

  10. Technical basis and evaluation criteria for an air sampling/monitoring program

    International Nuclear Information System (INIS)

    Gregory, D.C.; Bryan, W.L.; Falter, K.G.

    1993-01-01

    Air sampling and monitoring programs at DOE facilities need to be reviewed in light of revised requirements and guidance found in, for example, DOE Order 5480.6 (RadCon Manual). Accordingly, the Oak Ridge National Laboratory (ORNL) air monitoring program is being revised and placed on a sound technical basis. A draft technical basis document has been written to establish placement criteria for instruments and to guide the ''retrospective sampling or real-time monitoring'' decision. Facility evaluations are being used to document air sampling/monitoring needs, and instruments are being evaluated in light of these needs. The steps used to develop this program and the technical basis for instrument placement are described

  11. Sea surface temperature inter-hemispheric dipole and its relation to tropical precipitation

    International Nuclear Information System (INIS)

    Sun, Cheng; Li, Jianping; Ding, Ruiqiang; Jin, Fei-Fei

    2013-01-01

    Using different SST datasets, the variability of zonal mean SSTs is investigated. Besides the global warming mode, the variability is dominated by one equatorially symmetric mode and one antisymmetric mode. The former is most pronounced in the Pacific and dominated by interannual variability, corresponding to the ENSO signature. The latter features an inter-hemispheric dipole-like pattern and is referred to as the SST inter-hemispheric dipole (SSTID). The SSTID and Atlantic multidecadal oscillation are found to be related but distinct in the spatial pattern. Observational analysis shows that the SSTID significantly influences tropical rainfall and contributes to the north–south asymmetry of tropical precipitation on multidecadal timescales. The observed SSTID and its relation to the tropical rainfall are realistically reproduced in a control simulation with the UKMO-HadCM3 climate model. Results from the UKMO-HadCM3 simulation suggest that the SSTID is related to the variability of the global ocean northward cross-equatorial heat transport. (letter)

  12. Breastfeeding and the risk of childhood asthma: A two-stage instrumental variable analysis to address endogeneity.

    Science.gov (United States)

    Sharma, Nivita D

    2017-09-01

    Several explanations for the inconsistent results on the effects of breastfeeding on childhood asthma have been suggested. The purpose of this study was to investigate one unexplored explanation, which is the presence of a potential endogenous relationship between breastfeeding and childhood asthma. Endogeneity exists when an explanatory variable is correlated with the error term for reasons such as selection bias, reverse causality, and unmeasured confounders. Unadjusted endogeneity will bias the effect of breastfeeding on childhood asthma. To investigate potential endogeneity, a cross-sectional study of breastfeeding practices and incidence of childhood asthma in 87 pediatric patients in Georgia, the USA, was conducted using generalized linear modeling and a two-stage instrumental variable analysis. First, the relationship between breastfeeding and childhood asthma was analyzed without considering endogeneity. Second, tests for presence of endogeneity were performed and having detected endogeneity between breastfeeding and childhood asthma, a two-stage instrumental variable analysis was performed. The first stage of this analysis estimated the duration of breastfeeding and the second-stage estimated the risk of childhood asthma. When endogeneity was not taken into account, duration of breastfeeding was found to significantly increase the risk of childhood asthma (relative risk ratio [RR]=2.020, 95% confidence interval [CI]: [1.143-3.570]). After adjusting for endogeneity, duration of breastfeeding significantly reduced the risk of childhood asthma (RR=0.003, 95% CI: [0.000-0.240]). The findings suggest that researchers should consider evaluating how the presence of endogeneity could affect the relationship between duration of breastfeeding and the risk of childhood asthma. © 2017 EAACI and John Wiley and Sons A/S. Published by John Wiley and Sons Ltd.

  13. Evaluation of Technical Efficiency in Indian Sugar Industry: An Application of Full Cumulative Data Envelopment Analysis

    Directory of Open Access Journals (Sweden)

    Sunil KUMAR

    2012-05-01

    Full Text Available This study focuses on the inter-temporal and inter-state variations in technical and scale efficiency levels of Indian sugar industry. In the first stage, full cumulative data envelopment analysis (FCDEA is used to derive efficiency scores for 12 major sugar producing states. The panel data truncated regression is employed in the second stage to assess the key factors explaining the observed variations in the efficiency levels. The results suggest that the extent of technical inefficiency in Indian sugar industry is about 35.5 percent per annum, and the observed technical inefficiency stems primarily due to managerial inefficiency rather scale inefficiency. Also, a precipitous decline in the level of technical efficiency has been noticed in the postreforms period relative to the level observed in the pre-reforms period. The availability of skilled labour and profitability have been found to be most significant determinants of technical efficiency in Indian sugar industry.

  14. On the shape of posterior densities and credible sets in instrumental variable regression models with reduced rank: an application of flexible sampling methods using neural networks

    NARCIS (Netherlands)

    Hoogerheide, L.F.; Kaashoek, J.F.; van Dijk, H.K.

    2007-01-01

    Likelihoods and posteriors of instrumental variable (IV) regression models with strong endogeneity and/or weak instruments may exhibit rather non-elliptical contours in the parameter space. This may seriously affect inference based on Bayesian credible sets. When approximating posterior

  15. Preliminary results of a prospective study of inter- and intra-user variability of the Royal Veterinary College corneal clarity score (RVC-CCS) for use in veterinary practice.

    Science.gov (United States)

    Sanchez, Rick F; Dawson, Charlotte; Matas Riera, Màrian; Escanilla, Natàlia

    2016-07-01

    To introduce a new corneal clarity score for use in small animals and describe its inter- and intra-user variability. Twelve dogs and two cats with corneal abnormalities and five dogs with healthy corneas. Four examiners scored every patient twice and never consecutively, focusing on the central cornea. The peripheral cornea was scored separately. The following scoring system was used to describe corneal clarity: G0: no fundus reflection is visible on retroillumination (RI) using a head-mounted indirect ophthalmoscope. G1: a fundus reflection is visible with RI. G2: a 0.1-mm diameter light beam is visible on the anterior surface of the iris and/or lens. G3: gross fundic features are visible when viewed with indirect ophthalmoscopy (IO) using a head-mounted indirect ophthalmoscope and a hand-held 30D lens, although fine details are not clear. G4: fine details of the fundic features are clearly visible with IO. The minimum grades given were analyzed for inter- and intra-user variability with kappa analysis. Intra- and interuser variability of the central corneal clarity ranged from 0.78 to 0.96, showing substantial to almost perfect reproducibility, and from 0.66 to 0.91, showing substantial to almost perfect reliability, respectively. Intra- and interuser variability of the peripheral cornea ranged from 0.83 to 0.95, showing almost perfect agreement, and from 0.53 to 0.91, showing moderate to almost perfect agreement. The RVC-CCS is well suited to assess and monitor central corneal clarity in small animals and to compare outcomes between studies and different surgeons. © 2015 American College of Veterinary Ophthalmologists.

  16. OSCEs for undergraduate clinical examination in orthopaedics: inter ...

    African Journals Online (AJOL)

    ... D (Group 2) was 8.625. The p-value was 0.001148 (95% confidence interval). Conclusion: There was statistically significant inter-examiner variability. We recommend that for all OSCE exams, examiners be paired with a deliberate attempt to pair a “Hawk” with a “Dove”. Statistical correction of biases is also recommended.

  17. Dynamic inter-relationship between trade, economic growth and tourism in Malaysia

    OpenAIRE

    Sarmidi, Tamat; Salleh, Norlida H

    2010-01-01

    This study aims to test a hypothesis that postulate a positive inter-relationship between international flows of tourist, trade and economic growth. Although tourism is one of the major components in the trade of services, and it has been certified by large number of literatures on the strong correlation between tourism industry and economic development, yet not much is known on the dynamic inter-relationship between these three variables. Closing-up this gaping hole, this study employs the c...

  18. Inter-annual variability in the thermal structure of an oceanic time series station off Ecuador (1990-2003) associated with El Niño events

    Science.gov (United States)

    Garcés-Vargas, José; Schneider, Wolfgang; Abarca del Río, Rodrigo; Martínez, Rodney; Zambrano, Eduardo

    2005-10-01

    Previously unpublished data (1990-2003) from a marine station located 20 km off the coast of Ecuador (Station La Libertad, 02°12'S, 080°55'W) are employed to investigate oceanic inter-annual variability in the far eastern equatorial Pacific, and its relation to the central-eastern equatorial Pacific. La Libertad is the only time series station between the Galapagos Islands and the South American coast, the region most affected by El Niño events (El Niño 2 region, 0-5°S, 90°W-80°W). Although configured and serviced differently, station La Libertad can be looked at as an eastern extension of the TAO/TRITON monitoring system, whose easternmost mooring is located at 95°W, 1550 km offshore. This study of El Niño's impact on the thermocline and its relationship to sea surface temperature revealed anomalies in the thermocline at station La Libertad some 2-4 months before their appearance at the sea surface. Inter-annual variability, namely quasi-biennial and quasi-quadrennial oscillations, accounts for roughly 80% of the total variance in temperature anomalies observed in the water column at station La Libertad. The coincidence in both phase and amplitude of these inter-annual oscillations explains the strength of El Niño events in the water column off La Libertad. We further show that anomalies in heat content appear 8-9 weeks earlier at 140°W in the equatorial Pacific (6550 km away from the coast) than at the coast itself. The arrival of El Niño, which has important regional social consequences as well as those for local fisheries, could therefore be predicted in the sub-surface waters off Ecuador by using these anomalies as a complementary index. In addition, the speed of the eastward propagation of these El Niño-associated anomalies' suggests the possible participation of higher-order baroclinic mode Kelvin waves and associated interaction processes in the eastern Pacific, which should be further investigated.

  19. Effect of corruption on healthcare satisfaction in post-soviet nations: A cross-country instrumental variable analysis of twelve countries.

    Science.gov (United States)

    Habibov, Nazim

    2016-03-01

    There is the lack of consensus about the effect of corruption on healthcare satisfaction in transitional countries. Interpreting the burgeoning literature on this topic has proven difficult due to reverse causality and omitted variable bias. In this study, the effect of corruption on healthcare satisfaction is investigated in a set of 12 Post-Socialist countries using instrumental variable regression on the sample of 2010 Life in Transition survey (N = 8655). The results indicate that experiencing corruption significantly reduces healthcare satisfaction. Copyright © 2016 The Author. Published by Elsevier Ltd.. All rights reserved.

  20. On the shape of posterior densities and credible sets in instrumental variable regression models with reduced rank: an application of flexible sampling methods using neural networks

    NARCIS (Netherlands)

    L.F. Hoogerheide (Lennart); J.F. Kaashoek (Johan); H.K. van Dijk (Herman)

    2005-01-01

    textabstractLikelihoods and posteriors of instrumental variable regression models with strong endogeneity and/or weak instruments may exhibit rather non-elliptical contours in the parameter space. This may seriously affect inference based on Bayesian credible sets. When approximating such contours

  1. Method for efficient establishment of technical biodosimetry competence

    International Nuclear Information System (INIS)

    Stricklin, D.; Jaworska, Alicja; Arvidsson, E.

    2007-01-01

    The current gold standard in biodosimetry, the dicentric assay, requires documented technical competence. Expertise is developed over time by evaluation of thousands of metaphases. Competence is documented through establishment of a dose-response curve, required by any service laboratory performing biodosimetry. Consistent and reliable evaluations must be established for new observers that might contribute to analyses for biological dose assessments. Discrepancies in evaluations jeopardize the reliability of assessments. The Swedish Defence Research Agency (FOI) together with the Norwegian Radiation Protection Authority (NRPA) conducted an inter-calibration exercise for the purpose of establishing comparable scoring criteria for evaluation of aberrations in metaphases. The exercise revealed specific aberrations that were difficult to identify and were consistent sources of uncertainty. Subsequently, a report detailing the FOI's scoring criteria was developed with visual examples and a strategy for establishing technical competence in metaphase scoring in an efficient manner evolved. Key components of the strategy are the review of guidance for biodosimetry, performance of inter-calibration exercises with previously established data sets, review of incongruous evaluations with a well-established observer, follow-up exercises depending on the initial outcome, and inter-comparisons to document agreement. Methods suggested here could be applied in training of new personnel. Documentation of methods in other laboratories could facilitate more consistent scoring criteria among the biodosimetry community, a problem observed in previous international inter-comparisons. Improved consistency among biodosimetry laboratories could facilitate reliably sharing the work load among different members of the biodosimetry community in the event of a mass casualty accident

  2. First-Passage-Time Distribution for Variable-Diffusion Processes

    Science.gov (United States)

    Barney, Liberty; Gunaratne, Gemunu H.

    2017-05-01

    First-passage-time distribution, which presents the likelihood of a stock reaching a pre-specified price at a given time, is useful in establishing the value of financial instruments and in designing trading strategies. First-passage-time distribution for Wiener processes has a single peak, while that for stocks exhibits a notable second peak within a trading day. This feature has only been discussed sporadically—often dismissed as due to insufficient/incorrect data or circumvented by conversion to tick time—and to the best of our knowledge has not been explained in terms of the underlying stochastic process. It was shown previously that intra-day variations in the market can be modeled by a stochastic process containing two variable-diffusion processes (Hua et al. in, Physica A 419:221-233, 2015). We show here that the first-passage-time distribution of this two-stage variable-diffusion model does exhibit a behavior similar to the empirical observation. In addition, we find that an extended model incorporating overnight price fluctuations exhibits intra- and inter-day behavior similar to those of empirical first-passage-time distributions.

  3. Inter- and intra-observer variability in prostate definition with tissue harmonic and brightness mode imaging.

    Science.gov (United States)

    Sandhu, Gurpreet Kaur; Dunscombe, Peter; Meyer, Tyler; Pavamani, Simon; Khan, Rao

    2012-01-01

    The objective of this study was to compare the relative utility of tissue harmonic (H) and brightness (B) transrectal ultrasound (TRUS) images of the prostate by studying interobserver and intraobserver variation in prostate delineation. Ten patients with early-stage disease were randomly selected. TRUS images of prostates were acquired using B and H modes. The prostates on all images were contoured by an experienced radiation oncologist (RO) and five equally trained observers. The observers were blinded to information regarding patient and imaging mode. The volumes of prostate glands and areas of midgland slices were calculated. Volumes contoured were compared among the observers and between observer group and RO. Contours on one patient were repeated five times by four observers to evaluate the intraobserver variability. A one-sample Student t-test showed the volumes outlined by five observers are in agreement (p > 0.05) with the RO. Paired Student t-test showed prostate volumes (p = 0.008) and midgland areas (p = 0.006) with H mode were significantly smaller than that with B mode. Two-factor analysis of variances showed significant interobserver variability (p standard deviation of mean volumes and areas, and concordance indices. It was found that for small glands (≤35 cc) H mode provided greater interobserver consistency; however, for large glands (≥35 cc), B mode provided more consistent estimates. H mode provided superior inter- and intraobserver agreement in prostate volume definition for small to medium prostates. In large glands, H mode does not exhibit any additional advantage. Although harmonic imaging has not proven advantageous for all cases, its utilization seems to be judicious for small prostates. Crown Copyright © 2012. Published by Elsevier Inc. All rights reserved.

  4. LAMMA 500 principle and technical description of the instrument

    International Nuclear Information System (INIS)

    Vogt, H.; Heinen, H.J.; Meier, S.; Wechsung, R.

    1981-01-01

    The Laser Microprobe Mass Analyzer LAMMA 500 originally had been designed for the analysis of biomedical samples, especially thin sections, with high lateral resolution and extreme detection sensitivity. The principle of LAMMA is based on the excitation of a microvolume of the sample to an ionized state by a focused laser beam. The analytical information is derived from mass spectrometry of these ions. It is obvious that all elements of the periodic table and their isotopes can be detected. Various applications have demonstrated that besides element detection the instrument can also be used for the detection of organic and inorganic compounds. A detailed description of the LAMMA 500 instrument is given. (orig./RB)

  5. Advanced Instrumentation, Information, and Control Systems Technologies Technical Program Plan

    Energy Technology Data Exchange (ETDEWEB)

    Bruce Hallbert

    2012-09-01

    Reliable instrumentation, information, and control (II&C) systems technologies are essential to ensuring safe and efficient operation of the U.S. light water reactor (LWR) fleet. These technologies affect every aspect of nuclear power plant (NPP) and balance-of-plant operations. In 1997, the National Research Council conducted a study concerning the challenges involved in modernization of digital instrumentation and control systems in NPPs. Their findings identified the need for new II&C technology integration.

  6. Single-purpose nuclear medicine instruments

    International Nuclear Information System (INIS)

    Boucek, J.

    Nuclear medicine requires the most up-to-date specialized technical facilities. The paper underlines the factor of reliability in purpose-designed equipment used for basic examinations. The possibility is also discussed of the automation of standard nuclear medicine instruments

  7. International study on inter-reader variability for circulating tumor cells in breast cancer

    NARCIS (Netherlands)

    Ignatiadis, Michail; Riethdorf, Sabine; Bidard, François-Clement; Vaucher, Isabelle; Khazour, Mustapha; Rothe, Francoise; Metallo, Jessica; Rouas, Ghizlane; Payne, Rachel E.; Coombes, Raoul Charles; Teufel, Ingrid; Andergassen, Ulrich; Apostolaki, Stella; Politaki, Eleni; Mavroudis, Dimitris; Bessi, Silvia; Pestrin, Martta; di Leo, Angelo; Campion, Michael; Reinholz, Monica; Perez, Edith; Piccart, Martine; Borgen, Elin; Naume, Bjorn; Jimenez, Jose; Aura, Claudia Monica; Zorzino, Laura; Cassatella, Maria Cristina; Sandri, Maria Teresa; Mostert, Bianca; Sleijfer, Stefan; Kraan, Jaco; Janni, Wolfgang; Fehm, Tanja; Rack, Brigitte; Terstappen, Leonardus Wendelinus Mathias Marie; Repollet, Madeline; Pierga, Jean-Yves; Miller, Craig; Sotiriou, Christos; Michiels, Stefan; Pantel, Klaus

    2014-01-01

    IntroductionCirculating tumor cells (CTCs) have been studied in breast cancer with the CellSearch® system. Given the low CTC counts in non-metastatic breast cancer, it is important to evaluate the inter-reader agreement. MethodsCellSearch® images (N = 272) of either CTCs or white blood cells or

  8. Development and testing of an assessment instrument for the formative peer review of significant event analyses.

    Science.gov (United States)

    McKay, J; Murphy, D J; Bowie, P; Schmuck, M-L; Lough, M; Eva, K W

    2007-04-01

    To establish the content validity and specific aspects of reliability for an assessment instrument designed to provide formative feedback to general practitioners (GPs) on the quality of their written analysis of a significant event. Content validity was quantified by application of a content validity index. Reliability testing involved a nested design, with 5 cells, each containing 4 assessors, rating 20 unique significant event analysis (SEA) reports (10 each from experienced GPs and GPs in training) using the assessment instrument. The variance attributable to each identified variable in the study was established by analysis of variance. Generalisability theory was then used to investigate the instrument's ability to discriminate among SEA reports. Content validity was demonstrated with at least 8 of 10 experts endorsing all 10 items of the assessment instrument. The overall G coefficient for the instrument was moderate to good (G>0.70), indicating that the instrument can provide consistent information on the standard achieved by the SEA report. There was moderate inter-rater reliability (G>0.60) when four raters were used to judge the quality of the SEA. This study provides the first steps towards validating an instrument that can provide educational feedback to GPs on their analysis of significant events. The key area identified to improve instrument reliability is variation among peer assessors in their assessment of SEA reports. Further validity and reliability testing should be carried out to provide GPs, their appraisers and contractual bodies with a validated feedback instrument on this aspect of the general practice quality agenda.

  9. Kelvin wave coupling from TIMED and GOCE: Inter/intra-annual variability and solar activity effects

    Science.gov (United States)

    Gasperini, Federico; Forbes, Jeffrey M.; Doornbos, Eelco N.; Bruinsma, Sean L.

    2018-06-01

    The primary mechanism through which energy and momentum are transferred from the lower atmosphere to the thermosphere is through the generation and propagation of atmospheric waves. It is becoming increasingly evident that a few waves from the tropical wave spectrum preferentially propagate into the thermosphere and contribute to modify satellite drag. Two of the more prominent and well-established tropical waves are Kelvin waves: the eastward-propagating 3-day ultra-fast Kelvin wave (UFKW) and the eastward-propagating diurnal tide with zonal wave number 3 (DE3). In this work, Sounding of the Atmosphere using Broadband Emission Radiometry (SABER) temperatures at 110 km and Gravity field and steady-state Ocean Circulation Explorer (GOCE) neutral densities and cross-track winds near 260 km are used to demonstrate vertical coupling in this height regime due to the UFKW and DE3. Significant inter- and intra-annual variability is found in DE3 and the UFKW, with evidence of latitudinal broadening and filtering of the latitude structures with height due to the effect of dissipation and mean winds. Additionally, anti-correlation between the vertical penetration of these waves to the middle thermosphere and solar activity level is established and explained through the effect of molecular dissipation.

  10. Technical evaluation of the electrical, instrumentation, and control design aspects of the low temperature overpressure protection system for the Point Beach Nuclear Power Plant, Units 1 and 2

    Energy Technology Data Exchange (ETDEWEB)

    Laudenbach, D.H.

    1979-03-01

    The technical evaluation is presented for the electrical, instrumentation, and control design aspects of the low temperature overpressure protection system for the Point Beach nuclear power plant, Units 1 and 2. Design basis criteria used to evaluate the acceptability of the system included operator action, system testability, single failure criterion, and seismic Category I and IEEE Std-279-1971 criteria. This report is supplied as part of the Selected Electrical, Instrumentation, and Control Systems Issues Support Program being conducted for the U.S. Nuclear Regulatory Commission by Lawrence Livermore Laboratory.

  11. Technical evaluation of the electrical, instrumentation, and control design aspects of the low temperature overpressure protection system for the Point Beach Nuclear Power Plant, Units 1 and 2

    International Nuclear Information System (INIS)

    Laudenbach, D.H.

    1979-03-01

    The technical evaluation is presented for the electrical, instrumentation, and control design aspects of the low temperature overpressure protection system for the Point Beach nuclear power plant, Units 1 and 2. Design basis criteria used to evaluate the acceptability of the system included operator action, system testability, single failure criterion, and seismic Category I and IEEE Std-279-1971 criteria. This report is supplied as part of the Selected Electrical, Instrumentation, and Control Systems Issues Support Program being conducted for the U.S. Nuclear Regulatory Commission by Lawrence Livermore Laboratory

  12. A New IMS Based Inter-working Solution

    Science.gov (United States)

    Zhu, Zhongwen; Brunner, Richard

    With the evolution of third generation network, more and more multimedia services are developed and deployed. Any new service to be deployed in IMS network is required to inter-work with existing Internet communities or legacy terminal users in order to appreciate the end users, who are the main drivers for the service to succeed. The challenge for Inter-working between IMS (IP Multimedia Subsystem) and non-IMS network is “how to handle recipient’s address”. This is because each network has its own routable address schema. For instance, the address for Google Talk user is xmpp:xyz@google.com, which is un-routable in IMS network. Hereafter a new Inter-working (IW) solution between IMS and non-IMS network is proposed for multimedia services that include Instant Messaging, Chat, and File transfer, etc. It is an end-to-end solution built on IMS infrastructure. The Public Service Identity (PSI) defined in 3GPP standard (3rd Generation Partnership Project) is used to allow terminal clients to allocate this IW service. When sending the SIP (Session Initial Protocol) request out for multimedia services, the terminal includes the recipient’s address in the payload instead of the “Request-URI” header. In the network, the proposed solution provides the mapping rules between different networks in MM-IW (Multimedia IW). The detailed technical description and the corresponding use cases are present. The comparison with other alternatives is made. The benefits of the proposed solution are highlighted.

  13. iPod touch-assisted instrumentation of the spine: a technical report.

    Science.gov (United States)

    Jost, Gregory F; Bisson, Erica F; Schmidt, Meic H

    2013-12-01

    Instrumentation of the spine depends on choosing the correct insertion angles to implant screws. Although modern image guidance facilitates precise instrumentation of the spine, the equipment is costly and availability is limited. Although most surgeons use lateral fluoroscopy to guide instrumentation in the sagittal plane, the lateromedial angulation is often chosen by estimation. To overcome the associated uncertainty, iPod touch-based applications for measuring angles can be used to assist with screw implantation. To evaluate the use of the iPod touch to adjust instruments to the optimal axial insertion angle for placement of pedicle screws in the lumbar spine. Twenty lumbar pedicle screws in 5 consecutive patients were implanted using the iPod touch. The lateromedial angulation was measured on preoperative images and reproduced in the operative field with the iPod touch. The instruments to implant the screws were aligned with the side of the iPod for screw insertion. Actual screw angles were remeasured on postoperative imaging. We collected demographic, clinical, and operative data for each patient. In 16 of 20 screws, the accuracy of implantation was within 3 degrees of the ideal trajectory. The 4 screws with an angle mismatch of 7 to 13 degrees were all implanted at the caudal end of the exposure, where maintaining the planned angulation was impeded by strong muscles pushing medially. iPod touch-assisted instrumentation of the spine is a very simple technique, which, in combination with a lateral fluoroscopy, may guide placement of pedicle screws in the lumbar spine.

  14. Second international tsunami workshop on the technical aspects of tsunami warning systems, tsunami analysis, preparedness, observation and instrumentation

    International Nuclear Information System (INIS)

    1989-01-01

    The Second Workshop on the Technical Aspects of Tsunami Warning Systems, Tsunami Analysis, Preparedness, Observation, and Instrumentation, sponsored and convened by the Intergovernmental Oceanographic Commission (IOC), was held on 1-2 August 1989, in the modern and attractive research town of Academgorodok, which is located 20 km south from downtown Novosibirsk, the capital of Siberia, USSR. The Program was arranged in eight major areas of interest covering the following: Opening and Introduction; Survey of Existing Tsunami Warning Centers - present status, results of work, plans for future development; Survey of some existing seismic data processing systems and future projects; Methods for fast evaluation of Tsunami potential and perspectives of their implementation; Tsunami data bases; Tsunami instrumentation and observations; Tsunami preparedness; and finally, a general discussion and adoption of recommendations. The Workshop presentations not only addressed the conceptual improvements that have been made, but focused on the inner workings of the Tsunami Warning System, as well, including computer applications, on-line processing and numerical modelling. Furthermore, presentations reported on progress has been made in the last few years on data telemetry, instrumentation and communications. Emphasis was placed on new concepts and their application into operational techniques that can result in improvements in data collection, rapid processing of the data, in analysis and prediction. A Summary Report on the Second International Tsunami Workshop, containing abstracted and annotated proceedings has been published as a separate report. The present Report is a Supplement to the Summary Report and contains the full text of the papers presented at this Workshop. Refs, figs and tabs

  15. Climate Informed Economic Instruments to Enhance Urban Water Supply Resilience to Hydroclimatological Variability and Change

    Science.gov (United States)

    Brown, C.; Carriquiry, M.; Souza Filho, F. A.

    2006-12-01

    Hydroclimatological variability presents acute challenges to urban water supply providers. The impact is often most severe in developing nations where hydrologic and climate variability can be very high, water demand is unmet and increasing, and the financial resources to mitigate the social effects of that variability are limited. Furthermore, existing urban water systems face a reduced solution space, constrained by competing and conflicting interests, such as irrigation demand, recreation and hydropower production, and new (relative to system design) demands to satisfy environmental flow requirements. These constraints magnify the impacts of hydroclimatic variability and increase the vulnerability of urban areas to climate change. The high economic and social costs of structural responses to hydrologic variability, such as groundwater utilization and the construction or expansion of dams, create a need for innovative alternatives. Advances in hydrologic and climate forecasting, and the increasing sophistication and acceptance of incentive-based mechanisms for achieving economically efficient water allocation offer potential for improving the resilience of existing water systems to the challenge of variable supply. This presentation will explore the performance of a system of climate informed economic instruments designed to facilitate the reduction of hydroclimatologic variability-induced impacts on water-sensitive stakeholders. The system is comprised of bulk water option contracts between urban water suppliers and agricultural users and insurance indexed on reservoir inflows designed to cover the financial needs of the water supplier in situations where the option is likely to be exercised. Contract and insurance parameters are linked to forecasts and the evolution of seasonal precipitation and streamflow and designed for financial and political viability. A simulation of system performance is presented based on ongoing work in Metro Manila, Philippines. The

  16. OPTION(5) versus OPTION(12) instruments to appreciate the extent to which healthcare providers involve patients in decision-making.

    Science.gov (United States)

    Stubenrouch, Fabienne E; Pieterse, Arwen H; Falkenberg, Rijan; Santema, T Katrien B; Stiggelbout, Anne M; van der Weijden, Trudy; Aarts, J Annemijn W M; Ubbink, Dirk T

    2016-06-01

    The 12-item "observing patient involvement" (OPTION(12))-instrument is commonly used to assess the extent to which healthcare providers involve patients in health-related decision-making. The five-item version (OPTION(5)) claims to be a more efficient measure. In this study we compared the Dutch versions of the OPTION-instruments in terms of inter-rater agreement and correlation in outpatient doctor-patient consultations in various settings, to learn if we can safely switch to the shorter OPTION(5)-instrument. Two raters coded 60 audiotaped vascular surgery and oncology patient consultations using OPTION(12) and OPTION(5). Unweighted Cohen's kappa was used to compute inter-rater agreement on item-level. The association between the total scores of the two OPTION-instruments was investigated using Pearson's correlation coefficient (r) and a Bland & Altman plot. After fine-tuning the OPTION-manuals, inter-rater agreement for OPTION(12) and OPTION(5) was good to excellent (kappa range 0.69-0.85 and 0.63-0.72, respectively). Mean total scores were 23.7 (OPTION(12); SD=7.8) and 39.3 (OPTION(5); SD=12.7). Correlation between the total scores was high (r=0.71; p=0.01). OPTION(5) scored systematically higher with a wider range than OPTION(12). Both OPTION-instruments had a good inter-rater agreement and correlated well. OPTION(5) seems to differentiate better between various levels of patient involvement. The OPTION(5)-instrument is recommended for clinical application. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  17. Intra- and inter- correlative responses among fruits physical traits ...

    African Journals Online (AJOL)

    Intra- and inter- correlative responses among fruits physical traits, seedling growth parameters and fruit and nut proximate qualities of the Nigerian shea nut tree ... Results indicated that the first three PCA axes retained explained 96.3% of total variability among seedling provenances, revealing that leaf area, seedling girth, ...

  18. The Multicultural Personality Questionnaire : A multidimensional instrument of multicultural effectiveness

    NARCIS (Netherlands)

    Van der Zee, KI; Van Oudenhoven, JP

    2000-01-01

    In today's global business environment, executive work is becoming more international in orientation. Several skills and traits may underlie executive success in an inter national environment. The Multicultural Personality Questionnaire was developed as a multidimensional instrument aimed at

  19. Evaluation of the McMahon Competence Assessment Instrument for Use with Midwifery Students During a Simulated Shoulder Dystocia.

    Science.gov (United States)

    McMahon, Erin; Jevitt, Cecilia; Aronson, Barbara

    2018-03-01

    Intrapartum emergencies occur infrequently but require a prompt and competent response from the midwife to prevent morbidity and mortality of the woman, fetus, and newborn. Simulation provides the opportunity for student midwives to develop competence in a safe environment. The purpose of this study was to determine the inter-rater reliability of the McMahon Competence Assessment Instrument (MCAI) for use with student midwives during a simulated shoulder dystocia scenario. A pilot study using a nonprobability convenience sample was used to evaluate the MCAI. Content validity indices were calculated for the individual items and the overall instrument using data from a panel of expert reviewers. Fourteen student midwives consented to be video recorded while participating in a simulated shoulder dystocia scenario. Three faculty raters used the MCAI to evaluate the student performance. These quantitative data were used to determine the inter-rater reliability of the MCAI. The intraclass correlation coefficient (ICC) was used to assess the inter-rater reliability of MCAI scores between 2 or more raters. The ICC was 0.86 (95% confidence interval, 0.60-0.96). Fleiss's kappa was calculated to determine the inter-rater reliability for individual items. Twenty-three of the 42 items corresponded to excellent strength of agreement. This study demonstrates a method to determine the inter-rater reliability of a competence assessment instrument to be used with student midwives. Data produced by this study were used to revise and improve the instrument. Additional research will further document the inter-rater reliability and can be used to determine changes in student competence. Valid and reliable methods of assessment will encourage the use of simulation to efficiently develop the competence of student midwives. © 2018 by the American College of Nurse-Midwives.

  20. Maintenance of nuclear instruments

    International Nuclear Information System (INIS)

    Oliveira Rebelo, A.M. de; Santos, C.J.F. dos; Jesus, E.F.O. de; Silva, L.E.M.C.; Borges, J.C.

    1988-01-01

    A program to design and repairing of nuclear instruments for teaching and research was founded in the UFRJ to find solutions for technical support problem - The GEMD-RADIACOES. This group has assisted to several groups of the University in recuperation and conservation of devices like: Linear scanner, Cromatograph and system of radiation detection in general. Recuperation of these devices had required a study of theirs operations modes, to make it possible the setting up of a similar system. Recuperation also involves operation tests, calibration and technical for users, orienting them to get the best performance. (Author) [pt

  1. 1st Advanced Marine Renewable Energy Instrumentation Experts Workshop

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2011-10-01

    The U.S. marine energy industry is actively pursuing development of offshore wind and marine hydrokinetic (MHK) energy systems. Experience in the wind energy sector demonstrates that new technology development requires thorough measurement and characterization of the environmental conditions prevalent at installation sites and of technology operating in the field. Presently, there are no turn-key instrumentation system solutions that meet the measurement needs of the marine energy industry. The 1st Advanced Marine Renewable Energy Instrumentation Experts Workshop brought together technical experts from government laboratories, academia, and industry representatives from marine energy, wind, offshore oil and gas, and instrumentation developers to present and discuss the instrumentation needs of the marine energy industry. The goals of the meeting were to: 1. Share the latest relevant knowledge among technical experts; 2. Review relevant state-of-the-art field measurement technologies and methods; 3. Review lessons learned from recent field deployments; 4. Identify synergies across different industries; 5. Identify gaps between existing and needed instrumentation capabilities; 6. Understand who are the leading experts; 7. Provide a forum where stakeholders from the marine energy industry could provide substantive input in the development of new marine energy field deployable instrumentation packages.

  2. A comparison of RANZCR and Singapore-designed radiation oncology practice audit instruments: how does reproducibility affect future approaches to revalidation

    International Nuclear Information System (INIS)

    Lu, Jiade J.; Wynne, Christopher J.; Kumar, Mahesh B.; Shakespeare, Thomas P.; Mukherjee, Rahul; Back, Michael F.

    2004-01-01

    Physician competency assessment requires the use of validated methods and instruments. The Royal Australian and New Zealand College of Radiologists (RANZCR) developed a draft audit form to be evaluated as a competency assessment instrument for radiation oncologists (ROs) in Australasia. We evaluated the reliability of the RANZCR instrument as well as a separate The Cancer Institute (TCI) Singapore-designed instrument by having two ROs perform an independent chart review of 80 randomly selected patients seen at The Cancer Institute (TCI), Singapore. Both RANZCR and TCI Singapore instruments were used to score each chart. Inter- and intra-observer reliability for both audit instruments were compared using misclassification rates as the primary end-point. Overall, for inter-observer reproducibility, 2.3% of TCI Singapore items were misclassified compared to 22.3% of RANZCR items (P < 0.0001, 100.00% confidence that TCI instrument has less inter-observer misclassification). For intra-observer reproducibility, 2.4% of TCI Singapore items were misclassified compared to 13.6% of RANZCR items (P < 0.0001, 100.00% confidence that TCI instrument has less intra-observer misclassification). The proposed RANZCR RO revalidation audit instrument requires further refinement to improve validity. Several items require modification or removal because of lack of reliability, whereas inclusion of other important and reproducible items can be incorporated as demonstrated by the TCI Singapore instrument. The TCI Singapore instrument also has the advantage of incorporating a simple scoring system and criticality index to allow discrimination between ROs and comparisons against future College standards Copyright (2004) Blackwell Publishing Asia Pty Ltd

  3. Determinants of Inter-Country Internet Diffusion Rates

    OpenAIRE

    Wunnava, Phanindra V.; Leiter, Daniel B.

    2008-01-01

    This paper employs cross-sectional data from 100 countries to analyze the main determinants of inter-country Internet diffusion rates. We set up an empirical model based on strong theoretical foundations, in which we regress Internet usage on variables that capture social, economic and political differences between these countries. Our results support past findings that economic strength, infrastructure and knowledge of the English language positively affect Internet connectivity. In addition...

  4. The inter-observer variability of breast density scoring between mammography technologists and breast radiologists and its effect on the rate of adjuvant ultrasound.

    Science.gov (United States)

    Mazor, Roei D; Savir, Avital; Gheorghiu, David; Weinstein, Yuliana; Abadi-Korek, Ifat; Shabshin, Nogah

    2016-05-01

    This study assesses the inter-observer variability of mammographic breast density scoring (BDS) between technologists and radiologists and evaluates the effect of technologist patient referral on the load of adjuvant ultrasounds. In this IRB approved study, a retrospective analysis of 503 prospectively acquired, random mammograms was performed between January and March 2014. Each mammogram was evaluated for BDS independently and blindly by both the performing technologist and the interpreting radiologist. Statistical calculation of the Spearman correlation coefficient and weighted kappa were obtained to evaluate the inter-observer variability between technologists and radiologists and to examine whether it relates to the technologist's seniority or women's age. The effect on the load of adjuvant ultrasounds was evaluated. 10 mammography technologists and 7 breast radiologists participated in this study. BDS agreement levels between technologists and radiologists were in the fair to moderate range (kappa values: 0.3-0.45, Spearman coefficient values: 0.59-0.65). The technologists markedly over-graded the density compared to the radiologists in all the subsets evaluated. Comparison between low and high-density groups demonstrated a similar trend of over-grading by technologists, who graded 51% of the women as having dense breasts (scores 3-4) compared to 27% of the women graded as such by the radiologists. This trend of over grading breast density by technologists was unrelated to the women's age or to the technologists' seniority. Mammography technologists over-grade breast density. Technologists' referral to an adjuvant ultrasound leads to redundant ultrasound studies, unnecessary breast biopsies, costs and increased patient anxiety. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. A basic design of SR4 instrumentation and control system for research reactor

    International Nuclear Information System (INIS)

    Syahrudin Yusuf; M Subhan; Ikhsan Shobari; Sutomo Budihardjo

    2010-01-01

    An SR4 instrumentation and control systems of research reactor is the equipment of nuclear research reactors as power protection devices and control systems. The equipment is to monitor safety parameters and process parameters in the state of reactor shut down, start-up, and in operation at fixed power. In the engineering of Instrumentation and control systems SR4 research reactor, its basic design consists of technical specifications of the reactor protection system devices, technical specifications of the reactor power control system devices, technical specifications information system devices, and systems process termination cabling as a support system. This basic design is used as the basis for the preparation of detailed design and subsequent engineering development of instrumentation systems and control system integrated. (author)

  6. Revalidation of the Selection Instrument for Flight Training

    Science.gov (United States)

    2017-07-01

    flight training . ( Technical Report No. 1195). Arlington, VA: U.S. Army Research Institute for the Behavioral and Social Sciences. Department of...Research Report 2002 Revalidation of the Selection Instrument for Flight Training Victor Ingurgio U.S. Army Research...MICHELLE SAMS, Ph.D. Director Research accomplished for the Department of the Army. Technical Review by Dr. William Bickley

  7. Instrumental variables estimates of peer effects in social networks.

    Science.gov (United States)

    An, Weihua

    2015-03-01

    Estimating peer effects with observational data is very difficult because of contextual confounding, peer selection, simultaneity bias, and measurement error, etc. In this paper, I show that instrumental variables (IVs) can help to address these problems in order to provide causal estimates of peer effects. Based on data collected from over 4000 students in six middle schools in China, I use the IV methods to estimate peer effects on smoking. My design-based IV approach differs from previous ones in that it helps to construct potentially strong IVs and to directly test possible violation of exogeneity of the IVs. I show that measurement error in smoking can lead to both under- and imprecise estimations of peer effects. Based on a refined measure of smoking, I find consistent evidence for peer effects on smoking. If a student's best friend smoked within the past 30 days, the student was about one fifth (as indicated by the OLS estimate) or 40 percentage points (as indicated by the IV estimate) more likely to smoke in the same time period. The findings are robust to a variety of robustness checks. I also show that sharing cigarettes may be a mechanism for peer effects on smoking. A 10% increase in the number of cigarettes smoked by a student's best friend is associated with about 4% increase in the number of cigarettes smoked by the student in the same time period. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Biasogram: visualization of confounding technical bias in gene expression data

    DEFF Research Database (Denmark)

    Krzystanek, Marcin; Szallasi, Zoltan Imre; Eklund, Aron Charles

    2013-01-01

    Gene expression profiles of clinical cohorts can be used to identify genes that are correlated with a clinical variable of interest such as patient outcome or response to a particular drug. However, expression measurements are susceptible to technical bias caused by variation in extraneous factors...... such as RNA quality and array hybridization conditions. If such technical bias is correlated with the clinical variable of interest, the likelihood of identifying false positive genes is increased. Here we describe a method to visualize an expression matrix as a projection of all genes onto a plane defined...... by a clinical variable and a technical nuisance variable. The resulting plot indicates the extent to which each gene is correlated with the clinical variable or the technical variable. We demonstrate this method by applying it to three clinical trial microarray data sets, one of which identified genes that may...

  9. Problems with radiological surveillance instrumentation

    International Nuclear Information System (INIS)

    Swinth, K.L.; Tanner, J.E.; Fleming, D.M.

    1984-09-01

    Many radiological surveillance instruments are in use at DOE facilities throughout the country. These instruments are an essential part of all health physics programs, and poor instrument performance can increase program costs or compromise program effectiveness. Generic data from simple tests on newly purchased instruments shows that many instruments will not meet requirements due to manufacturing defects. In other cases, lack of consideration of instrument use has resulted in poor acceptance of instruments and poor reliability. The performance of instruments is highly variable for electronic and mechanical performance, radiation response, susceptibility to interferences and response to environmental factors. Poor instrument performance in these areas can lead to errors or poor accuracy in measurements

  10. Problems with radiological surveillance instrumentation

    International Nuclear Information System (INIS)

    Swinth, K.L.; Tanner, J.E.; Fleming, D.M.

    1985-01-01

    Many radiological surveillance instruments are in use at DOE facilities throughout the country. These instruments are an essential part of all health physics programs, and poor instrument performance can increase program costs or compromise program effectiveness. Generic data from simple tests on newly purchased instruments shows that many instruments will not meet requirements due to manufacturing defects. In other cases, lack of consideration of instrument use has resulted in poor acceptance of instruments and poor reliability. The performance of instruments is highly variable for electronic and mechanical performance, radiation response, susceptibility to interferences and response to environmental factors. Poor instrument performance in these areas can lead to errors or poor accuracy in measurements

  11. Relationship between intraoperative non-technical performance and technical events in bariatric surgery.

    Science.gov (United States)

    Fecso, A B; Kuzulugil, S S; Babaoglu, C; Bener, A B; Grantcharov, T P

    2018-03-30

    The operating theatre is a unique environment with complex team interactions, where technical and non-technical performance affect patient outcomes. The correlation between technical and non-technical performance, however, remains underinvestigated. The purpose of this study was to explore these interactions in the operating theatre. A prospective single-centre observational study was conducted at a tertiary academic medical centre. One surgeon and three fellows participated as main operators. All patients who underwent a laparoscopic Roux-en-Y gastric bypass and had the procedures captured using the Operating Room Black Box ® platform were included. Technical assessment was performed using the Objective Structured Assessment of Technical Skills and Generic Error Rating Tool instruments. For non-technical assessment, the Non-Technical Skills for Surgeons (NOTSS) and Scrub Practitioners' List of Intraoperative Non-Technical Skills (SPLINTS) tools were used. Spearman rank-order correlation and N-gram statistics were conducted. Fifty-six patients were included in the study and 90 procedural steps (gastrojejunostomy and jejunojejunostomy) were analysed. There was a moderate to strong correlation between technical adverse events (r s  = 0·417-0·687), rectifications (r s  = 0·380-0·768) and non-technical performance of the surgical and nursing teams (NOTSS and SPLINTS). N-gram statistics showed that after technical errors, events and prior rectifications, the staff surgeon and the scrub nurse exhibited the most positive non-technical behaviours, irrespective of operator (staff surgeon or fellow). This study demonstrated that technical and non-technical performances are related, on both an individual and a team level. Valuable data can be obtained around intraoperative errors, events and rectifications. © 2018 BJS Society Ltd Published by John Wiley & Sons Ltd.

  12. Technical co-operation for nuclear safety in developing countries

    International Nuclear Information System (INIS)

    Flakus, F.N.; Giuliani, P.

    1984-01-01

    The Agency's programme on technical co-operation for nuclear safety is, largely, responsive in character and the Agency's response is tailored to needs identified by developing countries. However, the Agency's assistance alone is not sufficient: technical co-operation can only be successful and is most effective when there is also a strong input from the counterpart body participating in a particular project. The commitment of national governments is fundamental to success. Technical co-operation is most fruitful if the Agency's assistance capabilities and the recipient country's co-operation capabilities match. Co-operation activities mostly take the form of single projects hosted by individual institutions within a single country; regional and inter-regional projects are also important

  13. The Cerro Tololo Inter-American Observatory Summer Student Programs in La Serena, Chile

    Science.gov (United States)

    Kaleida, Catherine C.; Smith, C.; Van Der Bliek, N. S.; James, D.

    2014-01-01

    The Cerro Tololo Inter-American Observatory (CTIO) offers positions for U.S. and Chilean student interns during the Chilean summer months of January-March (northern winter semester) at the CTIO offices in La Serena, Chile. CTIO is part of the National Optical Astronomy Observatory (NOAO) of the United States, focused on the development of astronomy in the southern hemisphere. Six undergraduate research assistantships are offered for U.S. physics and astronomy undergraduate students through the NSF-funded Research Experiences for Undergraduates (REU) program. The CTIO-funded Prácticas de Investigación en Astronomía (PIA) program is run concurrently with the REU program, and offers two research assistantships for Chilean undergraduate or 1st or 2nd year masters students, also at the CTIO offices in La Serena, Chile. The CTIO REU and PIA programs provide exceptional opportunities for students considering a career in astronomy to engage in substantive research activities with scientists working at the forefront of contemporary astrophysics. Student participants work on specific research projects in close collaboration with members of the CTIO scientific and technical staff, such as galaxy clusters, gravitational lensing, supernovae, planetary nebulae, stellar populations, star clusters, star formation, variable stars and interstellar medium. The CTIO REU and PIA programs emphasize observational techniques and provide opportunities for direct observational experience using CTIO's state-of-the-art telescopes and instrumentation. The programs run for 10 weeks, from mid-January to the end of March. A two-night observing run on Cerro Tololo and a field trip to another observatory in Chile are included for students of both programs. These positions are full time, and those selected will receive a modest stipend and subsidized housing on the grounds of the offices of CTIO in La Serena, as well as travel costs to and from La Serena. In addition, the students have the

  14. Health physics instrumentation needs

    International Nuclear Information System (INIS)

    Selby, J.M.; Swinth, K.L.; Kenoyer, J.L.

    1984-10-01

    Deficiencies and desirable improvements can be identified in every technical area in which health physics instruments are employed. The needed improvements cover the full spectrum including long-term reliability, human factors, accuracy, ruggedness, ease of calibration, improved radiation response, and improved mixed field response. Some specific areas of deficiency noted along with needed improvements. 17 references

  15. The use of GIS in determining the impacts of climate variability on ...

    African Journals Online (AJOL)

    This study developed a Geographical Information Systems (GIS) database and mapped inter-annual changes in tuber crop yield, as a response to inter-annual rainfall variability in the Guinea Savanna ecological zone of Nigeria. It also related the spatiotemporal variability in rainfall with tuber yields. Two major tuber crops, ...

  16. Inter-individual variability in cortical excitability and motor network connectivity following multiple blocks of rTMS.

    Science.gov (United States)

    Nettekoven, Charlotte; Volz, Lukas J; Leimbach, Martha; Pool, Eva-Maria; Rehme, Anne K; Eickhoff, Simon B; Fink, Gereon R; Grefkes, Christian

    2015-09-01

    The responsiveness to non-invasive neuromodulation protocols shows high inter-individual variability, the reasons of which remain poorly understood. We here tested whether the response to intermittent theta-burst stimulation (iTBS) - an effective repetitive transcranial magnetic stimulation (rTMS) protocol for increasing cortical excitability - depends on network properties of the cortical motor system. We furthermore investigated whether the responsiveness to iTBS is dose-dependent. To this end, we used a sham-stimulation controlled, single-blinded within-subject design testing for the relationship between iTBS aftereffects and (i) motor-evoked potentials (MEPs) as well as (ii) resting-state functional connectivity (rsFC) in 16 healthy subjects. In each session, three blocks of iTBS were applied, separated by 15min. We found that non-responders (subjects not showing an MEP increase of ≥10% after one iTBS block) featured stronger rsFC between the stimulated primary motor cortex (M1) and premotor areas before stimulation compared to responders. However, only the group of responders showed increases in rsFC and MEPs, while most non-responders remained close to baseline levels after all three blocks of iTBS. Importantly, there was still a large amount of variability in both groups. Our data suggest that responsiveness to iTBS at the local level (i.e., M1 excitability) depends upon the pre-interventional network connectivity of the stimulated region. Of note, increasing iTBS dose did not turn non-responders into responders. The finding that higher levels of pre-interventional connectivity precluded a response to iTBS could reflect a ceiling effect underlying non-responsiveness to iTBS at the systems level. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Combined role of heat and water stresses on wheat, maize and rice inter-annual variability and trend from 1980 to 2010.

    Science.gov (United States)

    Zampieri, M.; Ceglar, A., , Dr; Dentener, F., , Dr; van den Berg, M., , Dr; Toreti, A., , Dr

    2017-12-01

    Heat waves and drought are often considered the most damaging climatic stressors for wheat and maize. In this study, based on data derived from observations, we characterize and attribute the effects of these climate extremes on wheat and maize yield anomalies (at global and national scales) with respect to the mean trend from 1980 to 2010. Using a combination of up-to-date heat wave and drought indexes (i.e. the Heat Magnitude Day, HMD, and the Standardized Precipitation Evapotranspiration Index, SPEI), we have developed a composite indicator (i.e. the Combined Stress Index, CSI) that is able to capture the spatio-temporal characteristics of the underlying physical processes in the different agro-climatic regions of the world. At the global level, our diagnostic explains the 42% and the 50% of the inter-annual wheat and maize production variabilities, respectively. The relative importance of heat stress and drought in determining the yield anomalies depends on the region. Compared to maize, and in contrast to common perception, water excess affects wheat production more than drought in several countries. The index definition can be modified in order to quantify the role of combined heat and water stress events occurrence in determining the recorded yield trends as well. Climate change is increasingly limiting maize yields in several countries, especially in Europe and China. A comparable opposite signal, albeit less statistically significant, is found for the USA, which is the main world producer. As for rice, we provide a statistical evidence pointing out to the importance of considering the interactions with the horizontal surface waters fluxes carried out by the rivers. In fact, compared to wheat and maize, the CSI statistical skills in explaining rice production variability are quite reduced. This issue is particularly relevant in paddy fields and flooded lowlands where rice is mainly grown. Therefore, we have modified the procedure including a proxy for the

  18. Observer variability when evaluating patient movement from electronic portal images of pelvic radiotherapy fields

    International Nuclear Information System (INIS)

    Geraint Lewis, D.; Ryan, Karen R.; Smith, Cyril W.

    2005-01-01

    Background and purpose: A study has been performed to evaluate inter-observer variability when assessing pelvic patient movement using an electronic portal imaging device (EPID). Materials and methods: Four patient image sets were used with 3-6 portal images per set. The observer group consisted of nine radiographers with 3-18 months clinical EPID experience. The observers outlined bony landmarks on a digital simulator image and used matching software to evaluate field placement errors (FPEs) on each portal image relative to the reference simulator image. Data were evaluated statistically, using a two-component analysis of variance technique, to quantify both the inter-observer variability in evaluating FPEs and inter-fraction variability in patient position relative to the residuals of the analysis. Intra-observer variability was also estimated using four of the observers carrying out three sets of repeat readings. Results: Eight sets of variance data were analysed, based on FPEs in two orthogonal directions for each of the four patient image sets studied. Initial analysis showed that both inter-observer variation and inter-fraction-patient position variation were statistically significant (P<0.05) in seven of the eight cases evaluated. The averaged root-mean-square (RMS) deviation of the observers from the group mean was 1.1 mm, with a maximum deviation of 5.0 mm recorded for an individual observer. After additional training and re-testing of two of the observers who recorded the largest deviations from the group mean, a subsequent analysis showed the inter-observer variability for the group to be significant in only three of the eight cases, with averaged RMS deviation reduced to 0.5 mm, with a maximum deviation of 2.7 mm. The intra-observer variability was 0.5 mm, averaged over the four observers tested. Conclusions: We have developed a quantitative approach to evaluate inter-observer variability in terms of its statistical significance compared to inter

  19. Variability of gastric emptying time using standardized radiolabeled meals

    International Nuclear Information System (INIS)

    Christian, P.E.; Brophy, C.M.; Egger, M.J.; Taylor, A.; Moore, J.G.

    1984-01-01

    To define the range of inter- and intra-subject variability on gastric emptying measurements, eight healthy male subjects (ages 19-40) received meals on four separate occasions. The meal consisted of 150 g of beef stew labeled with Tc-99m SC labeled liver (600 μCi) and 150 g of orange juice containing In-111 DTPA (100 μCi) as the solid- and liquid-phase markers respectively. Images of the solid and liquid phases were obtained at 20 min intervals immediately after meal ingestion. The stomach region was selected from digital images and data were corrected for radionuclide interference, radioactive decay and the geometric mean of anterior and posterior counts. More absolute variability was seen with the solid than the liquid marker emptying for the group. The mean solid half-emptying time was 58 +- 17 min (range 29-92) while the mean liquid half-emptying time was 24 +- 8 min (range 12-37). A nested random effects analysis of variance showed moderate intra-subject variability for solid half-emptying times (rho = 0.4594), and high intra-subject variability was implied by a low correlation (rho = 0.2084) for liquid half-emptying. The average inter-subject differences were 58.3% of the total variance for solids (rho = 0.0017). For liquids, the inter-subject variability was 69.1% of the total variance, but was only suggestive of statistical significance (rho = 0.0666). The normal half emptying time for gastric emptying of liquids and solids is a variable phenomenon in healthy subjects and has great inter- and intra-individual day-to-day differences

  20. Variability of gastric emptying time using standardized radiolabeled meals

    Energy Technology Data Exchange (ETDEWEB)

    Christian, P.E.; Brophy, C.M.; Egger, M.J.; Taylor, A.; Moore, J.G.

    1984-01-01

    To define the range of inter- and intra-subject variability on gastric emptying measurements, eight healthy male subjects (ages 19-40) received meals on four separate occasions. The meal consisted of 150 g of beef stew labeled with Tc-99m SC labeled liver (600 ..mu..Ci) and 150 g of orange juice containing In-111 DTPA (100 ..mu..Ci) as the solid- and liquid-phase markers respectively. Images of the solid and liquid phases were obtained at 20 min intervals immediately after meal ingestion. The stomach region was selected from digital images and data were corrected for radionuclide interference, radioactive decay and the geometric mean of anterior and posterior counts. More absolute variability was seen with the solid than the liquid marker emptying for the group. The mean solid half-emptying time was 58 +- 17 min (range 29-92) while the mean liquid half-emptying time was 24 +- 8 min (range 12-37). A nested random effects analysis of variance showed moderate intra-subject variability for solid half-emptying times (rho = 0.4594), and high intra-subject variability was implied by a low correlation (rho = 0.2084) for liquid half-emptying. The average inter-subject differences were 58.3% of the total variance for solids (rho = 0.0017). For liquids, the inter-subject variability was 69.1% of the total variance, but was only suggestive of statistical significance (rho = 0.0666). The normal half emptying time for gastric emptying of liquids and solids is a variable phenomenon in healthy subjects and has great inter- and intra-individual day-to-day differences.

  1. Inter-laboratory evaluation of instrument platforms and experimental workflows for quantitative accuracy and reproducibility assessment

    Directory of Open Access Journals (Sweden)

    Andrew J. Percy

    2015-09-01

    Full Text Available The reproducibility of plasma protein quantitation between laboratories and between instrument types was examined in a large-scale international study involving 16 laboratories and 19 LC–MS/MS platforms, using two kits designed to evaluate instrument performance and one kit designed to evaluate the entire bottom-up workflow. There was little effect of instrument type on the quality of the results, demonstrating the robustness of LC/MRM-MS with isotopically labeled standards. Technician skill was a factor, as errors in sample preparation and sub-optimal LC–MS performance were evident. This highlights the importance of proper training and routine quality control before quantitation is done on patient samples.

  2. Atmospheric Research 2011 Technical Highlights

    Science.gov (United States)

    2012-01-01

    The 2011 Technical Highlights describes the efforts of all members of Atmospheric Research. Their dedication to advancing Earth Science through conducting research, developing and running models, designing instruments, managing projects, running field campaigns, and numerous other activities, is highlighted in this report.

  3. Modelo de Inmunización de un Swap de Tanto de Interés

    Directory of Open Access Journals (Sweden)

    Seijas Macías, J. A.

    1999-01-01

    Full Text Available El término swap o permuta financiera puede considerarse como un acuerdo de cambio de tipos de interés. Se basa en un cambio típico de flujos que surgen de un tanto fijo por flujos de interés variable. Exponemos la duración de inmunización de un swap de tanto de interés, aportando las consideraciones de diversos autores. Una cartera inmunizada es aquélla cuyo comportamiento es el mismo que el de una cartera objetivo dada, bajo el conjunto de medidas y criterios de riesgo predefinidos para el futuro.

  4. BRDF Characterization and Calibration Inter-Comparison between Terra MODIS, Aqua MODIS, and S-NPP VIIRS

    Science.gov (United States)

    Chang, Tiejun; Xiong, Xiaoxiong (Jack); Angal, Amit; Wu, Aisheng

    2016-01-01

    The inter-comparison of reflective solar bands (RSB) between Terra MODIS, Aqua MODIS, and SNPP VIIRS is very important for assessment of each instrument's calibration and to identify calibration improvements. One of the limitations of using their ground observations for the assessment is a lack of the simultaneous nadir overpasses (SNOs) over selected pseudo-invariant targets. In addition, their measurements over a selected Earth view target have significant difference in solar and view angles, and these differences magnify the effects of Bidirectional Reflectance Distribution Function (BRDF). In this work, an inter-comparison technique using a semi-empirical BRDF model is developed for reflectance correction. BRDF characterization requires a broad coverage of solar and view angles in the measurements over selected pseudo-invariant targets. Reflectance measurements over Libya 1, 2, and 4 desert sites from both the Aqua and Terra MODIS are regressed to a BRDF model with an adjustable coefficient accounting for the calibration difference between the two instruments. The BRDF coefficients for three desert sites for MODIS bands 1 to 9 are derived and the wavelength dependencies are presented. The analysis and inter-comparison are for MODIS bands 1 to 9 and VIIRS moderate resolution radiometric bands (M bands) M1, M2, M4, M5, M7, M8, M10 and imaging bands (I bands) I1-I3. Results show that the ratios from different sites are in good agreement. The ratios between Terra and Aqua MODIS from year 2003 to 2014 are presented. The inter-comparison between MODIS and VIIRS are analyzed for year 2014.

  5. The first Swedish nuclear reactor - from technical prototype to scientific instrument

    International Nuclear Information System (INIS)

    Fjaestad, M.

    2001-01-01

    The first Swedish reactor R1, constructed at the Royal Inst. of Technology in Stockholm, went critical in July 1954. This report presents historical aspects of the reactor, in particular about the reactor as a research instrument and a centre for physical science. The tensions between its role as a prototype and a step in the development of power reactors and that as a scientific instrument are especially focused

  6. Maintenance of nuclear medicine instruments in developing countries

    International Nuclear Information System (INIS)

    1976-01-01

    This report reviews the current nature and severity of the problems related to nuclear medicine instruments in developing countries and gives the recommendations of the Advisory Group on the development of improved strategies to assure that the instruments are effectively maintained while in use. A compilation of data from the Register of Medical Radioisotope Units (IAEA-167) on medical radioisotope instrumentation installed in developing countries and some comments and suggestions contained in reports of Agency Technical Assistance Experts are also presented

  7. DOE Fundamentals Handbook: Instrumentation and Control, Volume 1

    International Nuclear Information System (INIS)

    1992-06-01

    The Instrumentation and Control Fundamentals Handbook was developed to assist nuclear facility operating contractors provide operators, maintenance personnel, and the technical staff with the necessary fundamentals training to ensure a basic understanding of instrumentation and control systems. The handbook includes information on temperature, pressure, flow, and level detection systems; position indication systems; process control systems; and radiation detection principles. This information will provide personnel with an understanding of the basic operation of various types of DOE nuclear facility instrumentation and control systems

  8. DOE Fundamentals Handbook: Instrumentation and Control, Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    1992-06-01

    The Instrumentation and Control Fundamentals Handbook was developed to assist nuclear facility operating contractors provide operators, maintenance personnel, and the technical staff with the necessary fundamentals training to ensure a basic understanding of instrumentation and control systems. The handbook includes information on temperature, pressure, flow, and level detection systems; position indication systems; process control systems; and radiation detection principles. This information will provide personnel with an understanding of the basic operation of various types of DOE nuclear facility instrumentation and control systems.

  9. Utilizing inter-organizational relationships for new product development performance: A test of possible mediation effects

    DEFF Research Database (Denmark)

    Mortensen, Thomas Bøtker; Knudsen, Mette Præst

    The purpose of this paper is to investigate whether collaborative experience can act as a mediating variable on the use of inter-organizational relationships on NPD performance. The paper tests two different research questions: 1) Is there a possible mediating effect of experience on the linkage...... between inter-organizational relationships and performance? And If yes: what is the nature of the mediating effect and the resulting influence on performance? The paper is motivated by the growing literature on the importance of inter-organizational relationships created by the idea that firms operate...

  10. Instrumental variable analysis as a complementary analysis in studies of adverse effects : venous thromboembolism and second-generation versus third-generation oral contraceptives

    NARCIS (Netherlands)

    Boef, Anna G C; Souverein, Patrick C|info:eu-repo/dai/nl/243074948; Vandenbroucke, Jan P; van Hylckama Vlieg, Astrid; de Boer, Anthonius|info:eu-repo/dai/nl/075097346; le Cessie, Saskia; Dekkers, Olaf M

    2016-01-01

    PURPOSE: A potentially useful role for instrumental variable (IV) analysis may be as a complementary analysis to assess the presence of confounding when studying adverse drug effects. There has been discussion on whether the observed increased risk of venous thromboembolism (VTE) for

  11. Inter- and intra-observer variability associated with the use of the Mirels' scoring system for metastatic bone lesions.

    LENUS (Irish Health Repository)

    Mac Niocaill, Ruairi F

    2011-01-01

    Metastatic bone disease is increasing in association with ever-improving medical management of osteophylic malignant conditions. The precise timing of surgical intervention for secondary lesions in long bones can be difficult to determine. This paper aims to evaluate a classic scoring system. All radiographs were examined twice by three orthopaedic oncologists and scored according to the Mirels\\' scoring system. The Kappa statistic was used for the purpose of statistical analysis. The results show agreement between observers (κ = 0.35-0.61) for overall scores at the two time intervals. Inter-observer agreement was also seen with subset analysis of size (κ = 0.27-0.60), site (κ = 0.77-1.0) and nature of the lesion (κ = 0.55-0.81). Similarly, low levels of intra-observer variability were noted for each of the three surgeons (κ= 0.34, 0.39, and 0.78, respectively). These results indicate a reliable, repeatable assessment of bony metastases. We continue to advocate its use in the management of patients with long bone metastases.

  12. Technical evaluation of the electrical, instrumentation, and control design aspects of the override of containment purge valve isolation and other engineered safety feature signals for the Fort Calhoun Nuclear Power Plant

    International Nuclear Information System (INIS)

    Hackett, D.B.

    1980-01-01

    This report documents the technical evaluation of the electrical, instrumentation, and control design aspects of the override of containment purge valve isolation and other engineered safety feature signals for the Fort Calhoun nuclear power plant. The review criteria are based on IEEE Std-279-1971 requirements for the safety signals to all purge and ventilation isolation valves. This report is supplied as part of the Selected Electrical, Instrumentation, and Control Systems Issues Program being conducted for the US Nuclear Regulatory Commission by Lawrence Livermore Laboratory

  13. The Inter-Annual Variability Analysis of Carbon Exchange in Low Artic Fen Uncovers The Climate Sensitivity And The Uncertainties Around Net Ecosystem Exchange Partitioning

    Science.gov (United States)

    Blanco, E. L.; Lund, M.; Williams, M. D.; Christensen, T. R.; Tamstorf, M. P.

    2015-12-01

    An improvement in our process-based understanding of CO2 exchanges in the Arctic, and their climate sensitivity, is critical for examining the role of tundra ecosystems in changing climates. Arctic organic carbon storage has seen increased attention in recent years due to large potential for carbon releases following thaw. Our knowledge about the exact scale and sensitivity for a phase-change of these C stocks are, however, limited. Minor variations in Gross Primary Production (GPP) and Ecosystem Respiration (Reco) driven by changes in the climate can lead to either C sink or C source states, which likely will impact the overall C cycle of the ecosystem. Eddy covariance data is usually used to partition Net Ecosystem Exchange (NEE) into GPP and Reco achieved by flux separation algorithms. However, different partitioning approaches lead to different estimates. as well as undefined uncertainties. The main objectives of this study are to use model-data fusion approaches to (1) determine the inter-annual variability in C source/sink strength for an Arctic fen, and attribute such variations to GPP vs Reco, (2) investigate the climate sensitivity of these processes and (3) explore the uncertainties in NEE partitioning. The intention is to elaborate on the information gathered in an existing catchment area under an extensive cross-disciplinary ecological monitoring program in low Arctic West Greenland, established under the auspices of the Greenland Ecosystem Monitoring (GEM) program. The use of such a thorough long-term (7 years) dataset applied to the exploration in inter-annual variability of carbon exchange, related driving factors and NEE partition uncertainties provides a novel input into our understanding about land-atmosphere CO2 exchange.

  14. Morphometric variability of Arctodiaptomus salinus (Copepoda) in the Mediterranean-Black Sea region

    OpenAIRE

    ANUFRIIEVA, Elena V.; SHADRIN, Nickolai V.

    2015-01-01

    Inter-species variability in morphological traits creates a need to know the range of variability of characteristics in the species for taxonomic and ecological tasks. Copepoda Arctodiaptomus salinus, which inhabits water bodies across Eurasia and North Africa, plays a dominant role in plankton of different water bodies-from fresh to hypersaline. This work assesses the intra- and inter-population morphometric variability of A. salinus in the Mediterranean-Black Sea region and discusses some o...

  15. Adaptation and testing of psychosocial assessment instruments for cross-cultural use: an example from the Thailand Burma border.

    Science.gov (United States)

    Haroz, Emily E; Bass, Judith K; Lee, Catherine; Murray, Laura K; Robinson, Courtland; Bolton, Paul

    2014-01-01

    The purpose of this study was to develop valid and reliable instruments to assess priority psychosocial problems and functioning among adult survivors of systematic violence from Burma living in Thailand. The process involved four steps: 1) instrument drafting and piloting; 2) reliability and validity testing; 3) instrument revision; and 4) retesting revised instrument. A total of N = 158 interviews were completed. Overall subscales showed good internal consistency (0.73-0.92) and satisfactory combined test-retest/inter rater reliability (0.63-0.84). Criterion validity, was not demonstrated for any scale. The alcohol and functioning scales underperformed and were revised (step 3) and retested (step 4). Upon retesting, the function scale showed good internal consistency reliability (0.91-0.92), and the alcohol scale showed acceptable internal consistency (0.79) and strong test-retest/inter-rater reliability (0.86-0.89). This paper describes the importance and process of adaptation and testing, illustrated by the experiences and results for selected instruments in this population.

  16. Characteristics of protective instrumentation

    International Nuclear Information System (INIS)

    Reichart, G.

    1982-01-01

    Protective Instrumentation (PI) for Nuclear Power Plants (NPP) is a general term for an highly reliable instrumentation, which provides information for keeping the system within safe limits, for initation of countermeasures in the case of an incident or for mitigation of consequences of an accident. In German NPPs one can find a hierarchical structure of protective instrumentation, wherein the Reactor Protection System (RPS) has the highest priority. To meet the reliability requirements different design principles are used, like - redundancy - diversity - fail safe - decoupling. The presentation gives an overview about the different design principles and characterizes their reliability aspects. As an example for the technical realization the RPS of a German NPP is discussed in some detail. Furthermore some information about other type of PI is given and reliability aspects of the interaction of operating personell with these systems are mentioned. (orig.)

  17. FREPA - A Set of Instruments for the Development of Plurilingual and Inter-/Transcultural Competences

    DEFF Research Database (Denmark)

    Daryai-Hansen, Petra Gilliyard; Schröder-Sura, Anna

    2012-01-01

    The article presents a description and instructions for use of a set of tools that seeks to facilitate learners’ continuous development and strengthen plurilingual and inter- /transcultural competences. These tools have been developed within the research project Framework of Reference for Plurali...... and defines the concept of pluralistic approaches. The FREPA tools will be presented by answering the question as to how the FREPA tools can been used to describe and develop transcultural competences. Finally, the recent perspectives of the FREPA project will be outlined....

  18. INTER LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON

    Science.gov (United States)

    2018-03-26

    data by Instrumentation for Impact  Test , SAE standard J211‐1 [4]. Although the entire curve is collected, the interest of this  project  team  solely...HELMET BLUNT IMPACT TEST METHOD COMPARISON by Tony J. Kayhart Charles A. Hewitt and Jonathan Cyganik March 2018 Final...INTER-LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR

  19. Development and evaluation of the OHCITIES instrument: assessing alcohol urban environments in the Heart Healthy Hoods project

    Science.gov (United States)

    Sureda, Xisca; Espelt, Albert; Villalbí, Joan R; Cebrecos, Alba; Baranda, Lucía; Pearce, Jamie; Franco, Manuel

    2017-01-01

    Objectives To describe the development and test–retest reliability of OHCITIES, an instrument characterising alcohol urban environment in terms of availability, promotion and signs of consumption. Design This study involved: (1) developing the conceptual framework for alcohol urban environment by means of literature reviewing and previous alcohol environment research experience; (2) pilot testing and redesigning the instrument; (3) instrument digitalisation; (4) instrument evaluation using test–retest reliability. Setting Data for testing the reliability of the instrument were collected in seven census sections in Madrid in 2016 by two observers. Primary and secondary outcome measures We computed per cent agreement and Cohen’s kappa coefficients to estimate inter-rater and test–retest reliability for alcohol outlet environment measures. We calculated interclass coefficients and their 95% CIs to provide a measure of inter-rater reliability for signs of alcohol consumption measures. Results We collected information on 92 on-premise and 24 off-premise alcohol outlets identified in the studied areas about availability, accessibility and promotion of alcohol. Most per cent-agreement values for alcohol measures in on-premise and off-premise alcohol outlets were greater than 80%, and inter-rater and test–retest reliability values were generally above 0.80. Observers identified 26 streets and 3 public squares with signs of alcohol consumption. Intraclass correlation coefficient between observers for any type of signs of alcohol consumption was 0.50 (95% CI −0.09 to 0.77). Few items promoting alcohol unrelated to alcohol outlets were found on public spaces. Conclusions The OHCITIES instrument is a reliable instrument to characterise alcohol urban environment. This instrument might be used to understand how alcohol environment associates with alcohol behaviours and its related health outcomes, and can help in the design and evaluation of policies to reduce the

  20. Development of the Quality of Australian Nursing Documentation in Aged Care (QANDAC) instrument to assess paper-based and electronic resident records.

    Science.gov (United States)

    Wang, Ning; Björvell, Catrin; Hailey, David; Yu, Ping

    2014-12-01

    To develop an Australian nursing documentation in aged care (Quality of Australian Nursing Documentation in Aged Care (QANDAC)) instrument to measure the quality of paper-based and electronic resident records. The instrument was based on the nursing process model and on three attributes of documentation quality identified in a systematic review. The development process involved five phases following approaches to designing criterion-referenced measures. The face and content validities and the inter-rater reliability of the instrument were estimated using a focus group approach and consensus model. The instrument contains 34 questions in three sections: completion of nursing history and assessment, description of care process and meeting the requirements of data entry. Estimates of the validity and inter-rater reliability of the instrument gave satisfactory results. The QANDAC instrument may be a useful audit tool for quality improvement and research in aged care documentation. © 2013 ACOTA.

  1. SimilarityExplorer: A visual inter-comparison tool for multifaceted climate data

    Science.gov (United States)

    J. Poco; A. Dasgupta; Y. Wei; W. Hargrove; C. Schwalm; R. Cook; E. Bertini; C. Silva

    2014-01-01

    Inter-comparison and similarity analysis to gauge consensus among multiple simulation models is a critical visualization problem for understanding climate change patterns. Climate models, specifically, Terrestrial Biosphere Models (TBM) represent time and space variable ecosystem processes, for example, simulations of photosynthesis and respiration, using algorithms...

  2. Design requirements for the SWIFT instrument

    International Nuclear Information System (INIS)

    Rahnama, P; McDade, I; Shepherd, G; Gault, W

    2013-01-01

    The Stratospheric Wind Interferometer for Transport studies (SWIFT) instrument is a proposed limb-viewing satellite instrument that employs the method of Doppler Michelson interferometry to measure stratospheric wind velocities and ozone densities in the altitude range of 15–45 km. The values of the main instrument parameters including filter system parameters and Michelson interferometer parameters are derived using simulations and analyses. The system design requirements for the instrument and spacecraft are presented and discussed. Some of the retrieval-imposed design requirements are also discussed. Critical design issues are identified. The design optimization process is described. The sensitivity of wind measurements to instrument characteristics is investigated including the impact on critical design issues. Using sensitivity analyses, the instrument parameters were iteratively optimized in order to meet the science objectives. It is shown that wind measurements are sensitive to the thermal sensitivity of the instrument components, especially the narrow filter and the Michelson interferometer. The optimized values of the main system parameters including Michelson interferometer optical path difference, instrument visibility, instrument responsivity and knowledge of spacecraft velocity are reported. This work also shows that the filter thermal drift and the Michelson thermal drift are two main technical risks. (paper)

  3. Establishment of the Auditing National Service of quality to the instrumentation of Nuclear medicine in Cuba

    International Nuclear Information System (INIS)

    Varela C, C.; Diaz B, M.; Lopez B, G.M.; Torres A, L.A.; Coca P, M.A.

    2006-01-01

    Next to the vertiginous development of the technology in the Nuclear Medicine field, the possibility of early diagnosis of pathological processes without anatomical alterations, as well as its application with therapeutic purposes in the cancer treatment has grown. To assure a diagnosis and adapted therapy, it is vital to establish quality guarantee programs to the instrumentation. The State Medical Equipment Control Center (CCEEM), as regulator organ attributed to the Public Health Ministry of Cuba, it has licensed the Service of Quality Audits to the Nuclear medicine services, fulfilling all the technical and legal requirements to such effect. As base of these, the National Protocol for the Quality Control of the Instrumentation in Nuclear Medicine has been implemented, put out in vigour 2 national regulations, and an inter-institutional and multidisciplinary auditor equipment has been licensed. The different followed steps, as well as the realization of the first quality audits, its show not only a better execution of the tests and bigger professionalism of the involved specialists, but an increment in the taking of conscience to apply adequately the quality concepts for achieving a better service to the patient. On the other hand, the necessity of incorporating the clinical aspects to the audits, fomenting an integral harmonized advance of the quality guarantee programs is evidenced. (Author)

  4. NASA/DOD Aerospace Knowledge Diffusion Research Project. Paper 17: The relationship between seven variables and the use of US government technical reports by US aerospace engineers and scientists

    Science.gov (United States)

    Pinelli, Thomas E.; Barclay, Rebecca O.; Kennedy, John M.; Glassman, Nanci; Demerath, Loren

    1991-01-01

    A study was undertaken to investigate the relationship between the use of U.S. government technical reports by U.S. aerospace engineers and scientists and seven selected sociometric variables. Data were collected by means of a self-administered mail survey which was distributed to a randomly drawn sample of American Institute of Aeronautics and Astronautics (AIAA) members. Two research questions concerning the use of conference meeting papers, journal articles, in-house technical reports, and U.S. government technical reports were investigated. Relevance, technical quality, and accessibility were found to be more important determinants of the overall extent to which U.S. government technical reports and three other information products were used by U.S. aerospace engineers and scientists.

  5. Longitudinal intra and inter-individual variability in young swimmers performance and determinant factors

    OpenAIRE

    Morais, Jorge; Costa, Mário; Moreira, Marc; Forte, Pedro; Silva, António; Marinho, Daniel; Barbosa, Tiago

    2014-01-01

    The aim of study was to follow-up the intra-individual and inter-individual stability of talented swimmers’ performance and its anthropometrics, kinematics, hydrodynamics and efficiency during two competitive seasons. Thirty talented swimmers (14 boys: 12.33 ± 0.65 years; and 16 girls: 11.15 ± 0.55 years) were followed-up. Performance (100-m freestyle), anthropometrics (body mass, height, arm span, chest perimeter, trunk transverse surface area, hand and foot surface area), kinematics (stroke...

  6. Development of NPTC-11 intelligence control instrument with digital display

    International Nuclear Information System (INIS)

    Wang Chengming; Pu Li; Yu Jiang; Xue Yuping; Zhang Bo; Chen Yong

    2007-01-01

    The accurate of the process control gauge has direct influence on the safe operation of nuclear power plants. Therefore it is necessary to accumulate experiences for the domestic development of this Instrument. In this paper, NPTC-11 intelligence control Instrument with digital display is developed based on the design code for nuclear Instrument, considering the actual application requirements and technical redundancy. Its application in nuclear power plant for almost one year indicates that this Instrument satisfies the development purpose and requirements. (authors)

  7. NASA/DOD Aerospace Knowledge Diffusion Research Project. Report 6: The relationship between the use of US government technical reports by US aerospace engineers and scientists and selected institutional and sociometric variables. Ph.D. Thesis - Indiana Univ., Nov. 1990 No. 6

    Science.gov (United States)

    Pinelli, Thomas E.

    1991-01-01

    The relationship between the use of U.S. government technical reports by U.S. aerospace engineers and scientists and selected institutional and sociometric variables was investigated. The methodology used for this study was survey research. Data were collected by means of a self-administered mail questionnaire. The approximately 34,000 members of the American Institute of Aeronautics and Astronauts (AIAA) served as the study population. The response rate for the survey was 70 percent. A dependent relationship was found to exist between the use of U.S. government technical reports and three of the institutional variables (academic preparation, years of professional aerospace work experience, and technical discipline). The use of U.S. government technical reports was found to be independent of all of the sociometric variables. The institutional variables best explain the use of U.S. government technical reports by U.S. aerospace engineers and scientists.

  8. Musical instrument technology of the 20th century

    Science.gov (United States)

    Wheeler, Paul

    2004-05-01

    This paper presents a brief history of the technical development of musical instruments during the 20th century. Starting with early electronic instruments (such as the Theremin-1917) invented prior to the organization of ASA, the history includes the development of electronic organs, synthesizers, and computer music. This paper provides an introduction to the session, giving a framework for the papers which follow in the session.

  9. Project B-610 instrument data base. Revision 6

    International Nuclear Information System (INIS)

    Silvan, G.R.

    1994-01-01

    The following technical information document contains the published data base listing for the instrumentation to be connected into the new MICON distributed control computer. Project B-610 PFP Instrument Upgrade (PFP HVAC Control Room Upgrade) will install the MICON system in PFP and provide for a new control room at the present site of the new SWP change room EDT-150750 1/11/93

  10. Inter-Individual Variability in Acute Toxicity of R-Pulegone and R-Menthofuran in Human Liver Slices and Their Influence on miRNA Expression Changes in Comparison to Acetaminophen

    Directory of Open Access Journals (Sweden)

    Tomáš Zárybnický

    2018-06-01

    Full Text Available Monoterpenes R-pulegone (PUL and R-menthofuran (MF, abundant in the Lamiaceae family, are frequently used in herb and food products. Although their hepatotoxicity was shown in rodent species, information about their effects in human liver has been limited. The aim of our study was to test the effects of PUL, MF and acetaminophen (APAP, as a reference compound on cell viability and microRNA (miRNA expression in human precision-cut liver slices. Slices from five patients were used to follow up on the inter-individual variability. PUL was toxic in all liver samples (the half-maximal effective concentration was 4.0 µg/mg of tissue, while MF and surprisingly APAP only in two and three liver samples, respectively. PUL also changed miRNA expression more significantly than MF and APAP. The most pronounced effect was a marked decrease of miR-155-5p expression caused by PUL even in non-toxic concentrations in all five liver samples. Our results showed that PUL is much more toxic than MF and APAP in human liver and that miR-155-5p could be a good marker of PUL early hepatotoxicity. Marked inter-individual variabilities in all our results demonstrate the high probability of significant differences in the hepatotoxicity of tested compounds among people.

  11. The Job Training and Job Satisfaction Survey Technical Manual

    Science.gov (United States)

    Schmidt, Steven W.

    2004-01-01

    Job training has become an important aspect of an employee's overall job experience. However, it is not often called out specifically on instruments measuring job satisfaction. This technical manual details the processes used in the development and validation of a survey instrument to measure job training satisfaction and overall job…

  12. Inter- and intraobserver variability of MR arthrography in the detection and classification of superior labral anterior posterior (SLAP) lesions: evaluation in 78 cases with arthroscopic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Holzapfel, Konstantin; Waldt, Simone; Bruegel, Melanie; Rummeny, Ernst J.; Woertler, Klaus [Technische Universitaet Muenchen, Department of Radiology, Klinikum rechts der Isar, Munich (Germany); Paul, Jochen; Imhoff, Andreas B. [Technische Universitaet Muenchen, Department of Sports Orthopedics, Klinikum rechts der Isar, Munich (Germany); Heinrich, Petra [Technische Universitaet Muenchen, Institute of Medical Statistics and Epidemiology, Klinikum rechts der Isar, Munich (Germany)

    2010-03-15

    The purpose of this study was to determine inter- and intraobserver variability of MR arthrography of the shoulder in the detection and classification of superior labral anterior posterior (SLAP) lesions. MR arthrograms of 78 patients who underwent MR arthrography before arthroscopy were retrospectively analysed by three blinded readers for the presence and type of SLAP lesions. MR arthrograms were reviewed twice by each reader with a time interval of 4 months between the two readings. Inter- and intraobserver agreement for detection and classification of SLAP lesions were calculated using {kappa} coefficients. Arthroscopy confirmed 48 SLAP lesions: type I (n = 4), type II (n = 37), type III (n = 3), type IV (n = 4). Sensitivity and specificity for detecting SLAP lesions with MR arthrography for each reader were 88.6%/93.3%, 90.9%/80.0% and 86.4%/76.7%. MR arthrographic and arthroscopic grading were concurrent for 72.7%, 68.2% and 70.5% of SLAP lesions for readers 1-3, respectively. Interobserver agreement was excellent ({kappa} = 0.82) for detection and substantial ({kappa} = 0.63) for classification of SLAP lesions. For each reader intraobserver agreement was excellent for detection ({kappa} = 0.93, {kappa} = 0.97, {kappa} = 0.97) and classification ({kappa} = 0.94, {kappa} = 0.84, {kappa} = 0.93) of SLAP lesions. MR arthrography allows reliable and accurate detection of SLAP lesions. In addition, SLAP lesions can be diagnosed and classified with substantial to excellent inter- and intraobserver agreement. (orig.)

  13. Inter- and intraobserver variability of MR arthrography in the detection and classification of superior labral anterior posterior (SLAP) lesions: evaluation in 78 cases with arthroscopic correlation

    International Nuclear Information System (INIS)

    Holzapfel, Konstantin; Waldt, Simone; Bruegel, Melanie; Rummeny, Ernst J.; Woertler, Klaus; Paul, Jochen; Imhoff, Andreas B.; Heinrich, Petra

    2010-01-01

    The purpose of this study was to determine inter- and intraobserver variability of MR arthrography of the shoulder in the detection and classification of superior labral anterior posterior (SLAP) lesions. MR arthrograms of 78 patients who underwent MR arthrography before arthroscopy were retrospectively analysed by three blinded readers for the presence and type of SLAP lesions. MR arthrograms were reviewed twice by each reader with a time interval of 4 months between the two readings. Inter- and intraobserver agreement for detection and classification of SLAP lesions were calculated using κ coefficients. Arthroscopy confirmed 48 SLAP lesions: type I (n = 4), type II (n = 37), type III (n = 3), type IV (n = 4). Sensitivity and specificity for detecting SLAP lesions with MR arthrography for each reader were 88.6%/93.3%, 90.9%/80.0% and 86.4%/76.7%. MR arthrographic and arthroscopic grading were concurrent for 72.7%, 68.2% and 70.5% of SLAP lesions for readers 1-3, respectively. Interobserver agreement was excellent (κ = 0.82) for detection and substantial (κ = 0.63) for classification of SLAP lesions. For each reader intraobserver agreement was excellent for detection (κ = 0.93, κ = 0.97, κ = 0.97) and classification (κ = 0.94, κ = 0.84, κ = 0.93) of SLAP lesions. MR arthrography allows reliable and accurate detection of SLAP lesions. In addition, SLAP lesions can be diagnosed and classified with substantial to excellent inter- and intraobserver agreement. (orig.)

  14. Fuel Element Technical Manual

    Energy Technology Data Exchange (ETDEWEB)

    Burley, H.H. [ed.

    1956-08-01

    It is the purpose of the Fuel Element Technical Manual to Provide a single document describing the fabrication processes used in the manufacture of the fuel element as well as the technical bases for these processes. The manual will be instrumental in the indoctrination of personnel new to the field and will provide a single data reference for all personnel involved in the design or manufacture of the fuel element. The material contained in this manual was assembled by members of the Engineering Department and the Manufacturing Department at the Hanford Atomic Products Operation between the dates October, 1955 and June, 1956. Arrangement of the manual. The manual is divided into six parts: Part I--introduction; Part II--technical bases; Part III--process; Part IV--plant and equipment; Part V--process control and improvement; and VI--safety.

  15. A survey on the VXIbus and validity analyses for instrumentation and control in NPPs

    International Nuclear Information System (INIS)

    Kwon, Kee Choon; Park, Won Man

    1997-06-01

    This document presents the technical status of the VXIbus system and its interface. VMEbus, while developed as a backplane for Motorola processors, can be used for data acquisition, control and other instrumentation applications. The VXIbus and its associated standard for form, fit, and electrical interface have simplified the process of putting together automated instrumentation systems. The VXIplug and play system alliance was founded in 1993, the alliance's charter to improve the effectiveness of VXI-based solutions by increasing ease-of-use and improving the interoperability of mainframes, computers, instrumentations, and software through open, multivendor standards and practices. This technical report surveys surveys the instrumentation and control in NPPs apply to the VXI-based instruments which are studied expendability, interoperability, maintainability and other features. (author). 10 refs., 4 tabs., 25 figs

  16. Quantitative assessment of inter-observer variability in target volume delineation on stereotactic radiotherapy treatment for pituitary adenoma and meningioma near optic tract

    International Nuclear Information System (INIS)

    Yamazaki, Hideya; Ogita, Mikio; Yamashita, Koichi; Kotsuma, Tadayuki; Shiomi, Hiroya; Tsubokura, Takuji; Kodani, Naohiro; Nishimura, Takuya; Aibe, Norihiro; Udono, Hiroki; Nishikata, Manabu; Baba, Yoshimi

    2011-01-01

    To assess inter-observer variability in delineating target volume and organs at risk in benign tumor adjacent to optic tract as a quality assurance exercise. We quantitatively analyzed 21 plans made by 11 clinicians in seven CyberKnife centers. The clinicians were provided with a raw data set (pituitary adenoma and meningioma) including clinical information, and were asked to delineate the lesions and create a treatment plan. Their contouring and plans (10 adenoma and 11 meningioma plans), were then compared. In addition, we estimated the influence of differences in contouring by superimposing the respective contours onto a default plan. The median planning target volume (PTV) and the ratio of the largest to the smallest contoured volume were 9.22 cm 3 (range, 7.17 - 14.3 cm 3 ) and 1.99 for pituitary adenoma, and 6.86 cm 3 (range 6.05 - 14.6 cm 3 ) and 2.41 for meningioma. PTV volume was 10.1 ± 1.74 cm 3 for group 1 with a margin of 1 -2 mm around the CTV (n = 3) and 9.28 ± 1.8 cm 3 (p = 0.51) for group 2 with no margin (n = 7) in pituitary adenoma. In meningioma, group 1 showed larger PTV volume (10.1 ± 3.26 cm 3 ) than group 2 (6.91 ± 0.7 cm 3 , p = 0.03). All submitted plan keep the irradiated dose to optic tract within the range of 50 Gy (equivalent total doses in 2 Gy fractionation). However, contours superimposed onto the dose distribution of the default plan indicated that an excessive dose 23.64 Gy (up to 268% of the default plan) in pituitary adenoma and 24.84 Gy (131% of the default plan) in meningioma to the optic nerve in the contours from different contouring. Quality assurance revealed inter-observer variability in contour delineation and their influences on planning for pituitary adenoma and meningioma near optic tract

  17. Instrumentation Standard Architectures for Future High Availability Control Systems

    International Nuclear Information System (INIS)

    Larsen, R.S.

    2005-01-01

    Architectures for next-generation modular instrumentation standards should aim to meet a requirement of High Availability, or robustness against system failure. This is particularly important for experiments both large and small mounted on production accelerators and light sources. New standards should be based on architectures that (1) are modular in both hardware and software for ease in repair and upgrade; (2) include inherent redundancy at internal module, module assembly and system levels; (3) include modern high speed serial inter-module communications with robust noise-immune protocols; and (4) include highly intelligent diagnostics and board-management subsystems that can predict impending failure and invoke evasive strategies. The simple design principles lead to fail-soft systems that can be applied to any type of electronics system, from modular instruments to large power supplies to pulsed power modulators to entire accelerator systems. The existing standards in use are briefly reviewed and compared against a new commercial standard which suggests a powerful model for future laboratory standard developments. The past successes of undertaking such projects through inter-laboratory engineering-physics collaborations will be briefly summarized

  18. CONTRIBUTING FACTORS TOWARDS DIFFICULTIES IN GENERATING IDEAS AMONG TECHNICAL STUDENTS

    OpenAIRE

    Yee Mei Heong

    2013-01-01

    Idea is a thought or collection of thoughts that are important to decision making and problem solving.  The purpose of this research was to analysis the factors contributing to difficulty in generating ideas among technical students.  A total of 375 technical students from four technical universities in Malaysia were randomly selected as samples.  A set of questionnaires was developed and used as research instrument.  The findings indicated that a total of 319 (85.1%) technical students faced...

  19. Factors affecting ammonium uptake in streams - an inter-biome perspective

    Science.gov (United States)

    Jackson R Webster; Partick J. Mulholland; Jennifer L. Tanks; H. Maurice Valett; Walter K. Dodds; Bruce J. Peterson; William B. Bowden; Clifford N. Dahm; Stuart Findlay; Stanley V. Gregory; Nancy B. Grimm; Stephen K. Hamilton; Sherri L. Johnson; Eugenia Marti; William H. McDowell; Judy L. Meyer; Donna D. Morrall; Steven A. Thomas; Wilfred M. Wollhem

    2003-01-01

    1. The Lotic Intersite Nitrogen experiment (LINX) was a coordinated study of the relationships between North American biomes and factors governing ammonium uptake in streams. Our objective was to relate inter-biome variability of ammonium uptake to physical, chemical and biological processes. 2. Data were collected from 11 streams ranging from arctic to tropical and...

  20. Installation Of A Training Center With Nuclear Instruments In The I.N.E.A

    International Nuclear Information System (INIS)

    Camargo B, Ana C.; Periaza C, A.

    1993-01-01

    In the framework of the regional technical cooperation of the countries in development, at present, the IAEA executes some investigation projects such as the program of Regional Arrangements of Technical Cooperation for Latin America and Caribbean (ARCAL), from which the program of nuclear instrumentation ARCAL II is derived and by agreement the INEA should install a reference center in Electronic and Nuclear Instrumentation. To complete this objective it has assigned the development of different sub projects, among which is the installation of a training center for operation, cares and quality control of nuclear instruments of medical applications

  1. RBMK nuclear reactors: Proposals for instrumentation and control improvements to enhanced safety and availability. IEC technical report of type 3. Working material

    International Nuclear Information System (INIS)

    1995-01-01

    The present material presents a CD+V draft report ''RBMK nuclear reactors: Proposals for instrumentation and control improvements to enhance safety and availability'' prepared by the Joint IEC/IAEA team during 1993-1995. Experience has demonstrated the need to improve the safety instrumentation of the RBMK type reactors using well proven modern technology. The working group identified the upgrades and changes of the highest priority based on the evaluation of the RBMK systems and the events where the instrumentation was found to be inadequate for safe operation. The subjects discussed in this document were not selected on a systematic basis but were selected by the IEC and IAEA experts as considered to be appropriate to the activities of the IEC and for which technical experience was available. The items identified therefore do not reflect any ranking of the safety issues or any priority or impact on safety of any of the measures were they to be implemented. Many important safety issued and areas where physical measures are required to improve safety have been omitted and indeed not even acknowledged in this document. The recommendations presented in the document differ from those normally produced by the IEC in the form of standards as they are of a transitory nature and some have already been overtaken by the continuing process of improvements to plant safety. Figs and tabs

  2. Measuring participants' immersion in healthcare simulation: the development of an instrument.

    Science.gov (United States)

    Hagiwara, Magnus Andersson; Backlund, Per; Söderholm, Hanna Maurin; Lundberg, Lars; Lebram, Mikael; Engström, Henrik

    2016-01-01

    Immersion is important for simulation-based education; however, questionnaire-based instruments to measure immersion have some limitations. The aim of the present work is to develop a new instrument to measure immersion among participants in healthcare simulation scenarios. The instrument was developed in four phases: trigger identification, content validity scores, inter-rater reliability analysis and comparison with an existing immersion measure instrument. A modified Delphi process was used to develop the instrument and to establish validity and reliability. The expert panel consisted of 10 researchers. All the researchers in the team had previous experience of simulation in the health and/or fire and rescue services as researchers and/or educators and simulation designers. To identify triggers, the panel members independently screened video recordings from simulation scenarios. Here, a trigger is an event in a simulation that is considered a sign of reduced or enhanced immersion among simulation participants. The result consists of the Immersion Score Rating Instrument (ISRI). It contains 10 triggers, of which seven indicate reduced and three enhanced immersion. When using ISRI, a rater identifies trigger occurrences and assigns them strength between 1 and 3. The content validity analysis shows that all the 10 triggers meet an acceptable content validity index for items (I-CVI) standard. The inter-rater reliability (IRR) among raters was assessed using a two-way mixed, consistency, average-measures intra-class correlation (ICC). The ICC for the difference between weighted positive and negative triggers was 0.92, which indicates that the raters are in agreement. Comparison with results from an immersion questionnaire mirrors the ISRI results. In conclusion, we present a novel and non-intrusive instrument for identifying and rating the level of immersion among participants in healthcare simulation scenarios.

  3. Harmonization of the licensing process for digital instrumentation and control systems in nuclear power plants. Report prepared within the framework of the Technical Working Group on Nuclear Power Plant Control and Instrumentation

    International Nuclear Information System (INIS)

    2002-12-01

    This report was prepared in response to the recommendation of the Technical Working Group on Nuclear Power Plant Control and Instrumentation (TWG-NPPCI). This recommendation was based on the recognition of the present diversity in national practices in licensing digital Instrumentation and control (I and C). The goal of this report is to promote harmonization of I and C licensing requirements in the Member States. It applies to I and C modernization, retrofits, upgrades, replacement, new installation, and other aspects of digital I and C in both existing and new nuclear power plants. It should be pointed out that a single publication, like this report, can only take the first step towards initiating a process leading to licensing requirements, which are more harmonized. It is therefore hoped that that this report will get a broad readership among those who can influence requirements that are set on digital I and C. This report provides general and high level recommendations to assist senior officials at utilities, vendor organizations, regulatory bodies, and their support organizations who are involved in the licensing of digital I and C. It is also intended to be read by persons participating in technical committees which are writing standards. The authors of this report believe that harmonization can be achieved through a consideration of the technical and scientific basis of high integrity digital I and C systems. It is also believed that many benefits can be reached in resolving various issues of a technical and engineering nature, which presently are creating controversies in the licensing of digital I and C in NPP safety applications. This publication is based on a consideration of the licensing process of I and C in a top down fashion to discuss generic principles to be applied when assessing digital I and C in NPP safety applications. This report gives an overview of the confidence building process in which evidence is created that digital I and C fulfils

  4. Morphometric variability of Arctodiaptomus salinus (Copepoda) in the Mediterranean-Black Sea region.

    Science.gov (United States)

    Anufriieva, Elena V; Shadrin, Nickolai V

    2015-11-18

    Inter-species variability in morphological traits creates a need to know the range of variability of characteristics in the species for taxonomic and ecological tasks. Copepoda Arctodiaptomus salinus, which inhabits water bodies across Eurasia and North Africa, plays a dominant role in plankton of different water bodies-from fresh to hypersaline. This work assesses the intra- and inter-population morphometric variability of A. salinus in the Mediterranean-Black Sea region and discusses some observed regularities. The variability of linear body parameters and proportions was studied. The impacts of salinity, temperature, and population density on morphological characteristics and their variability can manifest themselves in different ways at the intra- and inter-population levels. A significant effect of salinity, pH and temperature on the body proportions was not found. Their intra-population variability is dependent on temperature and salinity. Sexual dimorphism of A. salinus manifests in different linear parameters, proportions, and their variability. There were no effects of temperature, pH and salinity on the female/male parameter ratio. There were significant differences in the body proportions of males and females in different populations. The influence of temperature, salinity, and population density can be attributed to 80%-90% of intra-population variability of A. salinus. However, these factors can explain less than 40% of inter-population differences. Significant differences in the body proportions of males and females from different populations may suggest that some local populations of A. salinus in the Mediterranean-Black Sea region are in the initial stages of differentiation.

  5. Instrument cables and ceramic-to-metal seals for fusion-environment service

    International Nuclear Information System (INIS)

    Cannon, C.P.

    1982-10-01

    The intent of this paper is to form a technical basis to address questions pertinent to the use of instrument cables, ceramic-to-metal seals, and connector components in a fusion environment. The service environment of future fusion devices poses a unique challenge to instrumentation. The radiation environment of 14 MeV neutrons is markedly different from other instrumented radiation environments. There exist other environmental concerns as well (some instruments may operate at elevated temperatures, etc)

  6. Statistical analysis of hydrological response in urbanising catchments based on adaptive sampling using inter-amount times

    Science.gov (United States)

    ten Veldhuis, Marie-Claire; Schleiss, Marc

    2017-04-01

    Urban catchments are typically characterised by a more flashy nature of the hydrological response compared to natural catchments. Predicting flow changes associated with urbanisation is not straightforward, as they are influenced by interactions between impervious cover, basin size, drainage connectivity and stormwater management infrastructure. In this study, we present an alternative approach to statistical analysis of hydrological response variability and basin flashiness, based on the distribution of inter-amount times. We analyse inter-amount time distributions of high-resolution streamflow time series for 17 (semi-)urbanised basins in North Carolina, USA, ranging from 13 to 238 km2 in size. We show that in the inter-amount-time framework, sampling frequency is tuned to the local variability of the flow pattern, resulting in a different representation and weighting of high and low flow periods in the statistical distribution. This leads to important differences in the way the distribution quantiles, mean, coefficient of variation and skewness vary across scales and results in lower mean intermittency and improved scaling. Moreover, we show that inter-amount-time distributions can be used to detect regulation effects on flow patterns, identify critical sampling scales and characterise flashiness of hydrological response. The possibility to use both the classical approach and the inter-amount-time framework to identify minimum observable scales and analyse flow data opens up interesting areas for future research.

  7. Quantitative assessment of inter-clinician variability of target volume delineation for medulloblastoma: quality assurance for the SIOP PNET 4 trial protocol

    International Nuclear Information System (INIS)

    Coles, Charlotte E.; Hoole, Andrew C.F.; Harden, Susan V; Burnet, Neil G.; Twyman, Nicola; Taylor, Roger E.; Kortmann, Rolf D.; Williams, Michael V.

    2003-01-01

    Background and purpose: To assess inter-clinician variability amongst specialist paediatric radiation oncologists in delineating clinical target volumes for treating medulloblastoma as a quality assurance exercise prior to the introduction of the SIOP PNET 4 trial protocol of conformal radiotherapy to the posterior fossa and tumour bed. Patients and methods: Participants from 17 UK centres attended an educational meeting and then completed a clinical planning exercise to outline: (1) the whole posterior fossa and (2) the tumour bed. Quantitative analysis of the volumes, lengths, spatial positioning and axial planes for each individual was carried out and variation between individuals analysed. Results: Outlining of the posterior fossa was reasonably consistent, although most variation was seen in defining the superior border of the tentorium. A major difference was the decision whether or not to include the post-surgical meningocoele in the clinical target volume (CTV). The CTV for the tumour bed was under treated by all participants due to lack of inclusion of pre-operative tumour extent. Conclusions: This exercise demonstrated several ambiguities in the draft protocol and highlighted particular areas of inter-clinician variation. Consequently the protocol was revised and improved to take account of these findings. We recommend that planning exercises, in conjunction with education and training, should be implemented before the start of any new radiotherapy trial. In the future, the use of image transfer will allow prospective peer review of target volumes before treatment commences. These measures are essential to ensure that alterations in clinical practice are achieved in a uniform way

  8. Inter-organisational communication networks in healthcare: centralised versus decentralised approaches.

    Science.gov (United States)

    Pirnejad, Habibollah; Bal, Roland; Stoop, Arjen P; Berg, Marc

    2007-05-16

    To afford efficient and high quality care, healthcare providers increasingly need to exchange patient data. The existence of a communication network amongst care providers will help them to exchange patient data more efficiently. Information and communication technology (ICT) has much potential to facilitate the development of such a communication network. Moreover, in order to offer integrated care interoperability of healthcare organizations based upon the exchanged data is of crucial importance. However, complications around such a development are beyond technical impediments. To determine the challenges and complexities involved in building an Inter-organisational Communication network (IOCN) in healthcare and the appropriations in the strategies. Interviews, literature review, and document analysis were conducted to analyse the developments that have taken place toward building a countrywide electronic patient record and its challenges in The Netherlands. Due to the interrelated nature of technical and non-technical problems, a socio-technical approach was used to analyse the data and define the challenges. Organisational and cultural changes are necessary before technical solutions can be applied. There are organisational, financial, political, and ethicolegal challenges that have to be addressed appropriately. Two different approaches, one "centralised" and the other "decentralised" have been used by Dutch healthcare providers to adopt the necessary changes and cope with these challenges. The best solutions in building an IOCN have to be drawn from both the centralised and the decentralised approaches. Local communication initiatives have to be supervised and supported centrally and incentives at the organisations' interest level have to be created to encourage the stakeholder organisations to adopt the necessary changes.

  9. At-Risk Learner Preference in Engineering/Technical Graphics: An Exploratory Study

    Science.gov (United States)

    Ernst, Jeremy V.

    2011-01-01

    This exploratory study investigated learner preferences of secondary Career and Technical Education (CTE) Engineering/Technical Graphics students using the VARK Questionnaire. The VARK Questionnaire is an instrument that assists in determining students' dominant preferred learning styles, whether visual, aural, reading, or kinesthetic. This study…

  10. Solar induced inter-annual variability of ozone

    Science.gov (United States)

    Fytterer, Tilo; Nieder, Holger; Perot, Kristell; Sinnhuber, Miriam; Stiller, Gabriele; Urban, Joachim

    2014-05-01

    Measurements by the Michelson Interferometer for Passive Atmospheric Sounding instrument on board the ENVIromental SATellite from 2005 - 2011 are used to investigate the impact of solar and geomagnetic activity on O3 in the stratosphere and mesosphere inside the Antarctic polar vortex. It is known from observations that energetic particles, mainly originating from the sun, precipitate in the Earth atmosphere and produce odd nitrogen NOx (N + NO + NO2) in the upper mesosphere and lower thermosphere, which is transported downwards into the stratosphere during polar winter. Results from global chemistry-transport models suggest that this leads to a depletion of O3 down to ~30 km at high latitudes during winter. Therefore it appears promising to search for a link between high energetic particles and O3 in actual data sets. Thus in this study, correlation analysis between a 26 days average centred around 1 Apr, 1 May and 1 Jun of several solar/geomagnetic indices (Ap index, F10.7 cm solar radio flux, Lyman-alpha, 2 MeV electrons flux) and 26 day running means from 1 Apr - 1 Nov of O3 in the altitude range from 20 - 70 km were performed. The results reveal negative correlation coefficients propagating downwards throughout the polar winter, at least for the Ap index and the 2 MeV electrons flux. Comparisons with TIMED/SABER and Odin/SMR O3 data are in moderate agreement, also showing a descending negative signal in either indices, but only for the correlation with 1 Apr.

  11. Evaluating structured assessment of anaesthesiologists' non-technical skills

    DEFF Research Database (Denmark)

    Jepsen, R M H G; Dieckmann, P; Spanager, L

    2016-01-01

    BACKGROUND: Non-technical skills (NTS) are essential for safe and efficient anaesthesia. Assessment instruments with appropriate validity evidence can be used to ensure that anaesthesiologists possess the NTS necessary to deliver high-standard patient care. The aims were to collect validity...... evidence using a contemporary validity framework for the assessment instrument Anaesthesiologists' Non-Technical Skills in Denmark (ANTSdk) regarding response process and internal structure (including reliability), and to investigate the effect of rater training on these properties. METHODS: An explorative...... study was undertaken at the Danish Institute for Medical Simulation, Copenhagen, Denmark. In a 1-day session, using ANTSdk, a convenience sample of 19 anaesthesiologists rated trainee anaesthesiologists' NTS in nine video-recorded simulation scenarios before and after a 3-h training session. RESULTS...

  12. Psychometric Evaluation of the D-Catch, an Instrument to Measure the Accuracy of Nursing Documentation.

    Science.gov (United States)

    D'Agostino, Fabio; Barbaranelli, Claudio; Paans, Wolter; Belsito, Romina; Juarez Vela, Raul; Alvaro, Rosaria; Vellone, Ercole

    2017-07-01

    To evaluate the psychometric properties of the D-Catch instrument. A cross-sectional methodological study. Validity and reliability were estimated with confirmatory factor analysis (CFA) and internal consistency and inter-rater reliability, respectively. A sample of 250 nursing documentations was selected. CFA showed the adequacy of a 1-factor model (chronologically descriptive accuracy) with an outlier item (nursing diagnosis accuracy). Internal consistency and inter-rater reliability were adequate. The D-Catch is a valid and reliable instrument for measuring the accuracy of nursing documentation. Caution is needed when measuring diagnostic accuracy since only one item measures this dimension. The D-Catch can be used as an indicator of the accuracy of nursing documentation and the quality of nursing care. © 2015 NANDA International, Inc.

  13. Exploring the relationship between anaesthesiologists' non-technical and technical skills.

    Science.gov (United States)

    Gjeraa, K; Jepsen, R M H G; Rewers, M; Østergaard, D; Dieckmann, P

    2016-01-01

    A combination of non-technical skills (NTS) and technical skills (TS) is crucial for anaesthetic patient management. However, a deeper understanding of the relationship between these two skills remains to be explored. We investigated the characteristics of trainee anaesthesiologists' NTS and TS in a simulated unexpected difficult airway management scenario. A mixed-method approach was used to explore the relationship between NTS and TS in 25 videos of 2nd year trainee anaesthesiologists managing a simulated difficult airway scenario. The videos were assessed using the customised version of the Anaesthetists' Non-Technical Skills System, ANTSdk, and an adapted TS checklist for calculating the correlation between NTS and TS. Written descriptions of the observed NTS were analysed using directed content analysis. The correlation between the NTS and the TS ratings was 0.106 (two-tailed significance of 0.613). Inter-rater reliability was substantial. Themes characterising good NTS included a systematic approach, planning and communicating decisions as well as responding to the evolving situation. A list of desirable, concrete NTS for the specific airway management situation was generated. This study illustrates that anaesthesiologist trainees' NTS and TS were not correlated in this setting, but rather intertwined and how the interplay of NTS and TS can impact patient management. Themes describing the characteristics of NTS and a list of desirable, concrete NTS were developed to aid the understanding, training and use of NTS. © 2015 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  14. Intra- and inter-subject variation in lower limb coordination during countermovement jumps in children and adults

    DEFF Research Database (Denmark)

    Raffalt, Peter C; Alkjær, Tine; Simonsen, Erik B

    2016-01-01

    -subject variability. Based on these results, it was concluded that the same movement solutions were available to both age groups, but the children were less able to consistently utilize the individually chosen coordination pattern. Thus, this ability appears to be developed through normal ontogenesis.......The purpose of the present study was to investigate the coordination pattern and coordination variability (intra-subject and inter-subject) in children and adults during vertical countermovement jumps. Ten children (mean age: 11.5±1.8years) and ten adults (mean age: 26.1±4.9years) participated...... in the experiment. Lower body 3D-kinematics and kinetics from both legs were obtained during 9 vertical jumps of each subject. Coordination pattern and coordination variability of intra-limb and inter-limb coupling were established by modified vector coding and continuous relative phase. The adult group jumped...

  15. Gastroenterology-Urology Devices; Manual Gastroenterology-Urology Surgical Instruments and Accessories. Final rule; technical amendment.

    Science.gov (United States)

    2017-03-01

    The Food and Drug Administration (FDA) is amending the identification of manual gastroenterology-urology surgical instruments and accessories to reflect that the device does not include specialized surgical instrumentation for use with urogyencologic surgical mesh specifically intended for use as an aid in the insertion, placement, fixation, or anchoring of surgical mesh during urogynecologic procedures ("specialized surgical instrumentation for use with urogynecologic surgical mesh"). These amendments are being made to reflect changes made in the recently issued final reclassification order for specialized surgical instrumentation for use with urogynecologic surgical mesh.

  16. Cosmopolitanism: Extending Our Theoretical Framework for Transcultural Technical Communication Research and Teaching

    Science.gov (United States)

    Palmer, Zsuzsanna Bacsa

    2013-01-01

    The effects of globalization on communication products and processes have resulted in document features and interactional practices that are sometimes difficult to describe within current theoretical frameworks of inter/transcultural technical communication. Although it has been recognized in our field that the old theoretical frameworks and…

  17. The Socio-Technical Design of a Library and Information Science Collaboratory

    Science.gov (United States)

    Lassi, Monica; Sonnenwald, Diane H.

    2013-01-01

    Introduction: We present a prototype collaboratory, a socio-technical platform to support sharing research data collection instruments in library and information science. No previous collaboratory has attempted to facilitate sharing digital research data collection instruments among library and information science researchers. Method: We have…

  18. Southern Hemisphere Carbon Monoxide Inferannual Variability Observed by Terra/Measurement of Pollution in the Troposphere (MOPITT)

    Science.gov (United States)

    Edwards, D. P.; Petron, G.; Novelli, P. C.; Emmons, L. K.; Gille, J. C.; Drummond, J. R.

    2010-01-01

    Biomass burning is an annual occurrence in the tropical southern hemisphere (SH) and represents a major source of regional pollution. Vegetation fires emit carbon monoxide (CO), which due to its medium lifetime is an excellent tracer of tropospheric transport. CO is also one of the few tropospheric trace gases currently observed from satellite and this provides long-term global measurements. In this paper, we use the 5 year CO data record from the Measurement Of Pollution In The Troposphere (MOPITT) instrument to examine the inter-annual variability of the SH CO loading and show how this relates to climate conditions which determine the intensity of fire sources. The MOPITT observations show an annual austral springtime peak in the SH zonal CO loading each year with dry-season biomass burning emissions in S. America, southern Africa, the Maritime Continent, and northwestern Australia. Although fires in southern Africa and S. America typically produce the greatest amount of CO, the most significant inter-annual variation is due to varying fire activity and emissions from the Maritime Continent and northern Australia. We find that this variation in turn correlates well with the El Nino Southern Oscillation precipitation index. Between 2000 and 2005, emissions were greatest in late 2002 and an inverse modeling of the MOPITT data using the MOZART chemical transport model estimates the southeast Asia regional fire source for the year August 2002 to September 2003 to be 52 Tg CO. Comparison of the MOPITT retrievals and NOAA surface network measurements indicate that the latter do not fully capture the inter-annual variability or the seasonal range of the CO zonal average concentration due to biases associated with atmospheric and geographic sampling.

  19. Technical specification optimization program - engineered safety features

    International Nuclear Information System (INIS)

    Andre, G.R.; Jansen, R.L.

    1986-01-01

    The Westinghouse Technical Specification Program (TOP) was designed to evaluate on a quantitative basis revisions to Nuclear Power Plant Technical Specifications. The revisions are directed at simplifying plant operation, and reducing unnecessary transients, shutdowns, and manpower requirements. In conjunction with the Westinghouse Owners Group, Westinghouse initiated a program to develop a methodology to justify Technical Specification revisions; particularly revisions related to testing and maintenance requirements on plant operation for instrumentation systems. The methodology was originally developed and applied to the reactor trip features of the reactor protection system (RPS). The current study further refined the methodology and applied it to the engineered safety features of the RPS

  20. Development and evaluation of the OHCITIES instrument: assessing alcohol urban environments in the Heart Healthy Hoods project.

    Science.gov (United States)

    Sureda, Xisca; Espelt, Albert; Villalbí, Joan R; Cebrecos, Alba; Baranda, Lucía; Pearce, Jamie; Franco, Manuel

    2017-10-05

    To describe the development and test-retest reliability of OHCITIES, an instrument characterising alcohol urban environment in terms of availability, promotion and signs of consumption. This study involved: (1) developing the conceptual framework for alcohol urban environment by means of literature reviewing and previous alcohol environment research experience; (2) pilot testing and redesigning the instrument; (3) instrument digitalisation; (4) instrument evaluation using test-retest reliability. Data for testing the reliability of the instrument were collected in seven census sections in Madrid in 2016 by two observers. We computed per cent agreement and Cohen's kappa coefficients to estimate inter-rater and test-retest reliability for alcohol outlet environment measures. We calculated interclass coefficients and their 95% CIs to provide a measure of inter-rater reliability for signs of alcohol consumption measures. We collected information on 92 on-premise and 24 off-premise alcohol outlets identified in the studied areas about availability, accessibility and promotion of alcohol. Most per cent-agreement values for alcohol measures in on-premise and off-premise alcohol outlets were greater than 80%, and inter-rater and test-retest reliability values were generally above 0.80. Observers identified 26 streets and 3 public squares with signs of alcohol consumption. Intraclass correlation coefficient between observers for any type of signs of alcohol consumption was 0.50 (95% CI -0.09 to 0.77). Few items promoting alcohol unrelated to alcohol outlets were found on public spaces. The OHCITIES instrument is a reliable instrument to characterise alcohol urban environment. This instrument might be used to understand how alcohol environment associates with alcohol behaviours and its related health outcomes, and can help in the design and evaluation of policies to reduce the harm caused by alcohol. © Article author(s) (or their employer(s) unless otherwise stated in the

  1. Instrumented fusion in a 12-month-old with atlanto-occipital dislocation: case report and literature review of infant occipitocervical fusion.

    Science.gov (United States)

    Hale, Andrew T; Dewan, Michael C; Patel, Bhairav; Geck, Matthew J; Tomycz, Luke D

    2017-08-01

    The treatment of atlantoaxial dislocation in very young children is challenging and lacks a consensus management strategy. We review the literature on infantile occipitocervical (OC) fusion is appraised and technical considerations are organized for ease of reference. Surgical decisions such as graft type and instrumentation details are summarized, along with the use of bone morphogenic protein and post-operative orthoses. We present the case of a 12-month-old who underwent instrumented occipitocervical (OC) fusion in the setting of traumatic atlanto-occipital dislocation (AOD). Occipitocervical (OC) arthrodesis is obtainable in very young infants and children. Surgical approaches are variable and use a combination of autologous grafting and creative screw and/or wire constructs. The heterogeneity of pathologic etiology leading to OC fusion makes it difficult to make definitive recommendations for surgical management.

  2. Rater reliability and concurrent validity of the Keyboard Personal Computer Style instrument (K-PeCS).

    Science.gov (United States)

    Baker, Nancy A; Cook, James R; Redfern, Mark S

    2009-01-01

    This paper describes the inter-rater and intra-rater reliability, and the concurrent validity of an observational instrument, the Keyboard Personal Computer Style instrument (K-PeCS), which assesses stereotypical postures and movements associated with computer keyboard use. Three trained raters independently rated the video clips of 45 computer keyboard users to ascertain inter-rater reliability, and then re-rated a sub-sample of 15 video clips to ascertain intra-rater reliability. Concurrent validity was assessed by comparing the ratings obtained using the K-PeCS to scores developed from a 3D motion analysis system. The overall K-PeCS had excellent reliability [inter-rater: intra-class correlation coefficients (ICC)=.90; intra-rater: ICC=.92]. Most individual items on the K-PeCS had from good to excellent reliability, although six items fell below ICC=.75. Those K-PeCS items that were assessed for concurrent validity compared favorably to the motion analysis data for all but two items. These results suggest that most items on the K-PeCS can be used to reliably document computer keyboarding style.

  3. CMIP5 land surface models systematically underestimate inter-annual variability of net ecosystem exchange in semi-arid southwestern North America.

    Science.gov (United States)

    MacBean, N.; Scott, R. L.; Biederman, J. A.; Vuichard, N.; Hudson, A.; Barnes, M.; Fox, A. M.; Smith, W. K.; Peylin, P. P.; Maignan, F.; Moore, D. J.

    2017-12-01

    Recent studies based on analysis of atmospheric CO2 inversions, satellite data and terrestrial biosphere model simulations have suggested that semi-arid ecosystems play a dominant role in the interannual variability and long-term trend in the global carbon sink. These studies have largely cited the response of vegetation activity to changing moisture availability as the primary mechanism of variability. However, some land surface models (LSMs) used in these studies have performed poorly in comparison to satellite-based observations of vegetation dynamics in semi-arid regions. Further analysis is therefore needed to ensure semi-arid carbon cycle processes are well represented in global scale LSMs before we can fully establish their contribution to the global carbon cycle. In this study, we evaluated annual net ecosystem exchange (NEE) simulated by CMIP5 land surface models using observations from 20 Ameriflux sites across semi-arid southwestern North America. We found that CMIP5 models systematically underestimate the magnitude and sign of NEE inter-annual variability; therefore, the true role of semi-arid regions in the global carbon cycle may be even more important than previously thought. To diagnose the factors responsible for this bias, we used the ORCHIDEE LSM to test different climate forcing data, prescribed vegetation fractions and model structures. Climate and prescribed vegetation do contribute to uncertainty in annual NEE simulations, but the bias is primarily caused by incorrect timing and magnitude of peak gross carbon fluxes. Modifications to the hydrology scheme improved simulations of soil moisture in comparison to data. This in turn improved the seasonal cycle of carbon uptake due to a more realistic limitation on photosynthesis during water stress. However, the peak fluxes are still too low, and phenology is poorly represented for desert shrubs and grasses. We provide suggestions on model developments needed to tackle these issues in the future.

  4. Usefulness of ACR MRI phantom for quality assurance of MRI instruments

    International Nuclear Information System (INIS)

    Lee, Jung Whee; Ahn, Kook Jin; Lee, Seung Koo; Na, Dong Gyu; Oh, Chang Hyun; Chang, Yong Min; Lim, Tae Hwan

    2006-01-01

    To examine whether the ACR phantom could be used in quality standards for magnetic resonance imaging (MRI) instruments in Korea. We conducted the phantom test using the ACR MRI phantom in 20 MRI instruments currently used in Korea. According to ACR criteria, we acquired the phantom images which were then assessed by the following seven tests: geometric accuracy, high spatial resolution, slice thickness accuracy, slice position accuracy, image intensity uniformity, percent signal ghosting, and low contrast object detectability. The phantom images were interpreted by three experienced radiologists according to ACR criteria. Then, we examined the failure rate of each test and evaluated the inter-observer variation in the measurements and test failure. The failure rate of each test could be broken into the following components: geometric accuracy (11-21%), high contrast spatial resolution (10-15%), slice thickness accuracy(6-22%), slice position accuracy (5-17%), image intensity uniformity (6%), percent signal ghosting (16%), and low contrast object detectability (8-10%). In this series, all the failure rates were less than 30%. In addition, no inter-observer variation was seen in the measurements and test failure. ACR MRI phantom promises to be established as the standard phantom for MRI instruments in Korea because of its objectivity in assessing the phantom images

  5. Descriptive analysis of context evaluation instrument for technical oral presentation skills evaluation: A case study in English technical communication course

    Science.gov (United States)

    Mohamed, Abdullah-Adnan; Asmawi, Adelina; Hamid, Mohd Rashid Ab; Mustafa, Zainol bin

    2015-02-01

    This paper reports a pilot study of Context Evaluation using a self-developed questionnaire distributed among engineering undergraduates at a university under study. The study aims to validate the self-developed questionnaires used in the Context evaluation, a component in the CIPP Model. The Context evaluation assesses background information for needs, assets, problems and opportunities relevant to beneficiaries of the study in a defined environment. Through the questionnaire, background information for the assessment of needs, assets and problems related to the engineering undergraduates' perceptions on the teaching and learning of technical oral presentation skills was collected and analysed. The questionnaire was developed using 5-points Likert scale to measure the constructs under study. They were distributed to 100 respondents with 79 returned. The respondents consisted of engineering undergraduates studied at various faculties at one technical university in Malaysia. The descriptive analysis of data for each item which makes up the construct for Context evaluation is found to be high. This implied that engineering undergraduates showed high interest in teaching and learning of technical oral presentation skills, thus their needs are met. Also, they agreed that assets and facilities are conducive to their learning. In conclusion, the context evaluation involving needs and assets factors are both considerably important; their needs are met and the assets and facilities do support their technical oral presentation skills learning experience.

  6. Density dependence and climate effects in Rocky Mountain elk: an application of regression with instrumental variables for population time series with sampling error.

    Science.gov (United States)

    Creel, Scott; Creel, Michael

    2009-11-01

    1. Sampling error in annual estimates of population size creates two widely recognized problems for the analysis of population growth. First, if sampling error is mistakenly treated as process error, one obtains inflated estimates of the variation in true population trajectories (Staples, Taper & Dennis 2004). Second, treating sampling error as process error is thought to overestimate the importance of density dependence in population growth (Viljugrein et al. 2005; Dennis et al. 2006). 2. In ecology, state-space models are used to account for sampling error when estimating the effects of density and other variables on population growth (Staples et al. 2004; Dennis et al. 2006). In econometrics, regression with instrumental variables is a well-established method that addresses the problem of correlation between regressors and the error term, but requires fewer assumptions than state-space models (Davidson & MacKinnon 1993; Cameron & Trivedi 2005). 3. We used instrumental variables to account for sampling error and fit a generalized linear model to 472 annual observations of population size for 35 Elk Management Units in Montana, from 1928 to 2004. We compared this model with state-space models fit with the likelihood function of Dennis et al. (2006). We discuss the general advantages and disadvantages of each method. Briefly, regression with instrumental variables is valid with fewer distributional assumptions, but state-space models are more efficient when their distributional assumptions are met. 4. Both methods found that population growth was negatively related to population density and winter snow accumulation. Summer rainfall and wolf (Canis lupus) presence had much weaker effects on elk (Cervus elaphus) dynamics [though limitation by wolves is strong in some elk populations with well-established wolf populations (Creel et al. 2007; Creel & Christianson 2008)]. 5. Coupled with predictions for Montana from global and regional climate models, our results

  7. Inter-Professional Practices of Private-Sector Physiotherapists for Low Back Pain Management: Who, How, and When?

    Science.gov (United States)

    Perreault, Kadija; Dionne, Clermont E; Rossignol, Michel; Poitras, Stéphane; Morin, Diane

    Purpose : Although there have been increasing demands for health care providers to take part in inter-professional practices in recent years, very little attention has been paid to the actualization of such practices in the private sector. This study describes private-sector physiotherapists' inter-professional practices regarding low back pain (LBP) management and identifies organizational and provider-level variables associated with the intensity of such practices. Method : A total of 327 randomly selected physiotherapists were surveyed in the province of Quebec. Data were analyzed using descriptive and multiple regression analyses. Results : Physiotherapists reported frequent interactions with other physiotherapists (daily/weekly for 52.6%), family physicians (51.0%), and physiotherapy (PT) assistants (45.2%), but infrequent interactions with psychologists (3.6%), neurosurgeons (0.9%), and chiropractors (0.3%). Frequently reported means of interactions were written and oral messages sent through clients (55.1% and 24.1%, respectively), face-to-face unplanned discussions (41.9%), and faxed or mailed letters (23.2%). Variables associated with the intensity of inter-professional practices (mean of 6.7 [ SD 1.7] out of 10 on the Intensity of Interprofessional Practices Questionnaire for Private Sector Physiotherapists) were related to physiotherapists' clientele, social activities with other providers, and perceptions of inter-professional practices as well as organizational models, vision, and provision of PT training. Conclusions: There is room to improve inter-professional practices with private-sector physiotherapists involved in managing LBP. Targets for action include physiotherapists and their workplaces.

  8. Technical Basis Document (TBD) and user guides

    International Nuclear Information System (INIS)

    Chiaro, P.J. Jr.

    1998-09-01

    A Technical Basis Document (TBD) should provide the background information for establishment of an instrument's operational requirements. Due to the amount and location of DOE facilities, no one set of requirements is possible. Operational requirements will vary based on the local environments and missions at each facility. Environmental conditions that can affect an instrument's operations are ambient temperature, humidity, and radio frequency, and to a lesser extent, magnetic fields, and interfering ionizing radiations. Consideration should also be made regarding how an instrument is to be used. If an instrument will be transported around the facility, vibration and shock can cause problems if they are not addressed in the TBD. This document provides guidance for the development of a TBD. This document applies to radiation instruments used for personnel and equipment contamination monitoring, dose rate monitoring, and air monitoring

  9. Quantifying the increasing sensitivity of power systems to climate variability

    Science.gov (United States)

    Bloomfield, H. C.; Brayshaw, D. J.; Shaffrey, L. C.; Coker, P. J.; Thornton, H. E.

    2016-12-01

    Large quantities of weather-dependent renewable energy generation are expected in power systems under climate change mitigation policies, yet little attention has been given to the impact of long term climate variability. By combining state-of-the-art multi-decadal meteorological records with a parsimonious representation of a power system, this study characterises the impact of year-to-year climate variability on multiple aspects of the power system of Great Britain (including coal, gas and nuclear generation), demonstrating why multi-decadal approaches are necessary. All aspects of the example system are impacted by inter-annual climate variability, with the impacts being most pronounced for baseload generation. The impacts of inter-annual climate variability increase in a 2025 wind-power scenario, with a 4-fold increase in the inter-annual range of operating hours for baseload such as nuclear. The impacts on peak load and peaking-plant are comparably small. Less than 10 years of power supply and demand data are shown to be insufficient for providing robust power system planning guidance. This suggests renewable integration studies—widely used in policy, investment and system design—should adopt a more robust approach to climate characterisation.

  10. Variability in "1"8F-FDG PET/CT methodology of acquisition, reconstruction and analysis for oncologic imaging: state survey

    International Nuclear Information System (INIS)

    Fischer, Andreia C.F. da S.; Druzian, Aline C.; Bacelar, Alexandre; Pianta, Diego B.; Silva, Ana M. Marques da

    2016-01-01

    The SUV in "1"8F-FDG PET/CT oncological imaging is useful for cancer diagnosis, staging and treatment assessment. There are, however, several factors that can give rise to bias in SUV measurements. When using SUV as a diagnostic tool, one needs to minimize the variability in this measurement by standardization of patient preparation, acquisition and reconstruction parameters. The aim of this study is to evaluate the methodological variability in PET/CT acquisition in Rio Grande do Sul State. For that, in each department, a questionnaire was applied to survey technical information from PET/CT systems and about the acquisitions and analysis methods utilized. All departments implement quality assurance programs consistent with (inter)national recommendations. However, the acquisition and reconstruction methods of acquired PET data differ. The implementation of a harmonized strategy for quantifying the SUV is suggested, in order to obtain greater reproducibility and repeatability. (author)

  11. IAEA technical meeting on integrating analog and digital instrumentation and control systems in hybrid main control rooms at nuclear power plants. Book of abstracts

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    issues apply to new build projects as well. Technical experts and managers from the field of instrumentation and control, process control, human factors engineering, licensing, and computer applications are invited to a Technical Meeting dealing with all important aspects of control room modernization projects. The subject of the present technical meeting was suggested by the members of the IAEA Technical Working Group on Nuclear Power Plant Control and Instrumentation (TWG-NPPCI) and supported by a number of IAEA meetings on NPP I and C Systems. Additional information on the Technical Working Group, and on the activities of the IAEA Division of Nuclear Power is available on The purpose of the meeting is to provide an international forum for presentations and discussions of experience with various aspects of the integration of analog and digital instrumentation and control systems in hybrid main control rooms, as applicable to both existing plants and planned (or in-progress) new plant builds. Promising new technologies and future trends in development will be also discussed. The meeting is intended for experts and managers in the I and C field from nuclear power utilities, vendor companies, licensing bodies, research organizations and academic institutions.

  12. Functional leg length discrepancy between theories and reliable instrumental assessment: a study about newly invented NPoS system.

    Science.gov (United States)

    Mahmoud, Asmaa; Abundo, Paolo; Basile, Luisanna; Albensi, Caterina; Marasco, Morena; Bellizzi, Letizia; Galasso, Franco; Foti, Calogero

    2017-01-01

    In spite the instinct social&financial impact of Leg Length Discrepancy (LLD), controversial and conflicting results still exist regarding a reliable assessment/correction method. For proper management it's essential to discriminate between anatomical&functional Leg Length Discrepancy (FLLD). With the newly invented NPoS (New Postural Solution), under the umbrella of the collaboration of PRM Department, Tor Vergata University with Baro Postural Instruments srl, positive results were observed in both measuring& compensating the hemi-pelvic antero-medial rotation in FLLD through personalized bilateral heel raise using two NPoS components: Foot Image System (FIS) and Postural Optimizer System (POS). This led our research interest to test the validity of NPoS as a preliminary step before evaluating its implementations in postural disorders. After clinical evaluation, 4 subjects with FLLD have been assessed by NPoS. Over a period of 2 months, every subject was evaluated 12 times by two different operators, 48 measurements in total, results have been verified in correlation to BTS GaitLab results. Intra-Operator&inter-operator variability analysis showed statistically insignificant differences, while inter-method variability between NPoS and BTS parameters expressed a linear correlation. Results suggest a significant validity of NPoS in assessment&correction of FLLD, with high degree of reproducibility with minimal operator dependency. This can be considered a base for promising clinical implications of NPoS as a reliable cost effective postural assessment/corrective tool. V.

  13. Correction of gene expression data: Performance-dependency on inter-replicate and inter-treatment biases.

    Science.gov (United States)

    Darbani, Behrooz; Stewart, C Neal; Noeparvar, Shahin; Borg, Søren

    2014-10-20

    This report investigates for the first time the potential inter-treatment bias source of cell number for gene expression studies. Cell-number bias can affect gene expression analysis when comparing samples with unequal total cellular RNA content or with different RNA extraction efficiencies. For maximal reliability of analysis, therefore, comparisons should be performed at the cellular level. This could be accomplished using an appropriate correction method that can detect and remove the inter-treatment bias for cell-number. Based on inter-treatment variations of reference genes, we introduce an analytical approach to examine the suitability of correction methods by considering the inter-treatment bias as well as the inter-replicate variance, which allows use of the best correction method with minimum residual bias. Analyses of RNA sequencing and microarray data showed that the efficiencies of correction methods are influenced by the inter-treatment bias as well as the inter-replicate variance. Therefore, we recommend inspecting both of the bias sources in order to apply the most efficient correction method. As an alternative correction strategy, sequential application of different correction approaches is also advised. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Outcome of instrumented spinal fusion for chronic low back pain: review of 100 patients

    International Nuclear Information System (INIS)

    Qureshi, M.A; Pasha, I.F.; Malik, A.S.; Asad, A.; Aebi, M.

    2010-01-01

    Objective of this study was to evaluate the outcome of instrumented spinal fusion in selected patients with Chronic Low Back Pain (CLBP) in our setup. Consecutive first one hundred patients were selected from spine unit database that underwent instrumented spinal fusion for chronic low back pain lasting more than one year, due to degenerative disease of spine. Average age was 42 years. There were 62 males and 38 females. Diagnosis included; spinal stenosis (26%), failed disc surgery (22%), spondylolisthesis (19%), degenerative disc disease (17%), and instability (16%). Operations performed; Pedicle Screw Fixation (PSF) with Postero-lateral Fusion (PLF) in 3% patients. Trans Laminar Facet Screw (TLFS) with PLF in 24% patients. Anterior Lumbar Inter-body Fusion (ALIF) in 9% patients. Posterior Lumbar Inter-body Fusion (PLIF) in 40% patients and Trans-foraminal Lumbar Inter-body Fusion (TLIF) in 24% patients. Average follow up was for 30 months. 86% patients had full spinal fusion. 71% patients were fully satisfied with treatment, 28% were partially satisfied. Post-operatively, on average, visual analogue scale (VAS) showed 48 points significant improvement and Oswestry Disability Index (ODI) showed 53 points significant improvement. Instrumented Spinal Fusion is effective in our set up for relieving symptoms and improving functional outcome in selected patients with debilitating Chronic Low Back Pain due to degenerative disease of spine. Single fusion technique is not ideal for all types of patients and surgeon has to be versatile and trained in using different fusion techniques as the situation demands. (author)

  15. Phenotypic Variability in the Coccolithophore Emiliania huxleyi.

    Science.gov (United States)

    Blanco-Ameijeiras, Sonia; Lebrato, Mario; Stoll, Heather M; Iglesias-Rodriguez, Debora; Müller, Marius N; Méndez-Vicente, Ana; Oschlies, Andreas

    2016-01-01

    Coccolithophores are a vital part of oceanic phytoplankton assemblages that produce organic matter and calcium carbonate (CaCO3) containing traces of other elements (i.e. Sr and Mg). Their associated carbon export from the euphotic zone to the oceans' interior plays a crucial role in CO2 feedback mechanisms and biogeochemical cycles. The coccolithophore Emiliania huxleyi has been widely studied as a model organism to understand physiological, biogeochemical, and ecological processes in marine sciences. Here, we show the inter-strain variability in physiological and biogeochemical traits in 13 strains of E. huxleyi from various biogeographical provinces obtained from culture collections commonly used in the literature. Our results demonstrate that inter-strain genetic variability has greater potential to induce larger phenotypic differences than the phenotypic plasticity of single strains cultured under a broad range of variable environmental conditions. The range of variation found in physiological parameters and calcite Sr:Ca highlights the need to reconsider phenotypic variability in paleoproxy calibrations and model parameterizations to adequately translate findings from single strain laboratory experiments to the real ocean.

  16. Phenotypic Variability in the Coccolithophore Emiliania huxleyi.

    Directory of Open Access Journals (Sweden)

    Sonia Blanco-Ameijeiras

    Full Text Available Coccolithophores are a vital part of oceanic phytoplankton assemblages that produce organic matter and calcium carbonate (CaCO3 containing traces of other elements (i.e. Sr and Mg. Their associated carbon export from the euphotic zone to the oceans' interior plays a crucial role in CO2 feedback mechanisms and biogeochemical cycles. The coccolithophore Emiliania huxleyi has been widely studied as a model organism to understand physiological, biogeochemical, and ecological processes in marine sciences. Here, we show the inter-strain variability in physiological and biogeochemical traits in 13 strains of E. huxleyi from various biogeographical provinces obtained from culture collections commonly used in the literature. Our results demonstrate that inter-strain genetic variability has greater potential to induce larger phenotypic differences than the phenotypic plasticity of single strains cultured under a broad range of variable environmental conditions. The range of variation found in physiological parameters and calcite Sr:Ca highlights the need to reconsider phenotypic variability in paleoproxy calibrations and model parameterizations to adequately translate findings from single strain laboratory experiments to the real ocean.

  17. Capturing Inter-Annual Variability of PV Energy Production in South Asia

    Energy Technology Data Exchange (ETDEWEB)

    Lopez, Anthony [National Renewable Energy Lab. (NREL), Golden, CO (United States); Maclaurin, Galen [National Renewable Energy Lab. (NREL), Golden, CO (United States); Roberts, Billy [National Renewable Energy Lab. (NREL), Golden, CO (United States); Rosenlieb, Evan [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2017-08-25

    Long-term variability of solar resource is an important factor in planning a utility-scale photovoltaic (PV) generation plant, and annual generation for a given location can vary significantly from year to year. Based on multiple years of solar irradiance data, an exceedance probability is the amount of energy that could potentially be produced by a power plant in any given year. An exceedance probability accounts for long-term variability and climate cycles (e.g., monsoons or changes in aerosols), which ultimately impact PV energy generation. Study results indicate that a significant bias could be associated with relying solely on typical meteorological year (TMY) resource data to capture long-term variability. While the TMY tends to under-predict annual generation overall compared to the P50, there appear to be pockets of over-prediction as well.

  18. Overview of the InterGroup protocols

    Energy Technology Data Exchange (ETDEWEB)

    Berket, Karlo [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Agarwal, Deborah A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Melliar-Smith, P. Michael [Univ. of California, Santa Barbara, CA (United States); Moser, Louise E. [Univ. of California, Santa Barbara, CA (United States)

    2001-03-01

    Existing reliable ordered group communication protocols have been developed for local-area networks and do not, in general, scale well to large numbers of nodes and wide-area networks. The InterGroup suite of protocols is a scalable group communication system that introduces a novel approach to handling group membership, and supports a receiver-oriented selection of service. The protocols are intended for a wide-area network, with a large number of nodes, that has highly variable delays and a high message loss rate, such as the Internet. The levels of the message delivery service range from unreliable unordered to reliable group timestamp ordered.

  19. Inter-organisational communication networks in healthcare: centralised versus decentralised approaches

    Directory of Open Access Journals (Sweden)

    Habibollah Pirnejad

    2007-05-01

    Full Text Available Background: To afford efficient and high quality care, healthcare providers increasingly need to exchange patient data. The existence of a communication network amongst care providers will help them to exchange patient data more efficiently. Information and communication technology (ICT has much potential to facilitate the development of such a communication network. Moreover, in order to offer integrated care interoperability of healthcare organizations based upon the exchanged data is of crucial importance. However, complications around such a development are beyond technical impediments. Objectives: To determine the challenges and complexities involved in building an Inter-organisational Communication network (IOCN in healthcare and the appropriations in the strategies. Case study: Interviews, literature review, and document analysis were conducted to analyse the developments that have taken place toward building a countrywide electronic patient record and its challenges in The Netherlands. Due to the interrelated nature of technical and non-technical problems, a socio-technical approach was used to analyse the data and define the challenges. Results: Organisational and cultural changes are necessary before technical solutions can be applied. There are organisational, financial, political, and ethicolegal challenges that have to be addressed appropriately. Two different approaches, one “centralised” and the other “decentralised” have been used by Dutch healthcare providers to adopt the necessary changes and cope with these challenges. Conclusion: The best solutions in building an IOCN have to be drawn from both the centralised and the decentralised approaches. Local communication initiatives have to be supervised and supported centrally and incentives at the organisations' interest level have to be created to encourage the stakeholder organisations to adopt the necessary changes.

  20. New instruments for radiation protection

    International Nuclear Information System (INIS)

    Bartos, D.; Ciobanu, M.; Constantin, F.; Petcu, M.; Plostinaru, V.D.; Rusu, Al.; Lupu, A.C.; Lupu, F.

    2003-01-01

    Though a century old, the radiation protection is actual by its purpose: a dose as low as reasonable achievable is to be received either by involved professionals or population. This threshold is dependent on the technical progress. Some major developments like surface mounted device technology, consumer almost ideal operational amplifiers, microcontrollers and the news signal digital processing techniques, offer the opportunity to design improved instruments for radioprotection. To put in a light portable instrument both the whole measuring system and the 'intelligence' - a microcontroller and the associated software - are the main ideas applied by the authors. The result is presented: a family of eight members, at least, based on two parents. (authors)

  1. Development of an instrument for the evaluation of advanced life support performance.

    Science.gov (United States)

    Peltonen, L-M; Peltonen, V; Salanterä, S; Tommila, M

    2017-10-01

    Assessing advanced life support (ALS) competence requires validated instruments. Existing instruments include aspects of technical skills (TS), non-technical skills (NTS) or both, but one instrument for detailed assessment that suits all resuscitation situations is lacking. This study aimed to develop an instrument for the evaluation of the overall ALS performance of the whole team. This instrument development study had four phases. First, we reviewed literature and resuscitation guidelines to explore items to include in the instrument. Thereafter, we interviewed resuscitation team professionals (n = 66), using the critical incident technique, to determine possible additional aspects associated with the performance of ALS. Second, we developed an instrument based on the findings. Third, we used an expert panel (n = 20) to assess the validity of the developed instrument. Finally, we revised the instrument based on the experts' comments and tested it with six experts who evaluated 22 video recorded resuscitations. The final version of the developed instrument had 69 items divided into adherence to guidelines (28 items), clinical decision-making (5 items), workload management (12 items), team behaviour (8 items), information management (6 items), patient integrity and consideration of laymen (4 items) and work routines (6 items). The Cronbach's α values were good, and strong correlations between the overall performance and the instrument were observed. The instrument may be useful for detailed assessment of the team's overall performance, but the numerous items make the use demanding. The instrument is still under development, and more research is needed to determine its psychometric properties. © 2017 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  2. TECHNICAL COORDINATION

    CERN Multimedia

    A. Ball and W. Zeuner

    2011-01-01

    In this report we will review the main achievements of the Technical Stop and the progress of several centrally-managed projects to support CMS operation and maintenance and prepare the way for upgrades. Overview of the extended Technical Stop  The principal objectives of the extended Technical Stop affecting the detector itself were the installation of the TOTEM T1 telescopes on both ends, the readjustment of the alignment link-disk in YE-2, the replacement of the light-guide sleeves for all PMs of both HFs, and some repairs on TOTEM T2 and CASTOR. The most significant tasks were, however, concentrated on the supporting infrastructure. A detailed line-by-line leak search was performed in the C6F14 cooling system of the Tracker, followed by the installation of variable-frequency drives on the pump motors of the SS1 and SS2 tracker cooling plants to reduce pressure transients during start-up. In the electrical system, larger harmonic filters were installed in ...

  3. Inter-laboratory variation in DNA damage using a standard comet assay protocol

    DEFF Research Database (Denmark)

    Forchhammer, Lykke; Ersson, Clara; Loft, Steffen

    2012-01-01

    determined the baseline level of DNA strand breaks (SBs)/alkaline labile sites and formamidopyrimidine DNA glycosylase (FPG)-sensitive sites in coded samples of mononuclear blood cells (MNBCs) from healthy volunteers. There were technical problems in seven laboratories in adopting the standard protocol...... analysed by the standard protocol. The SBs and FPG-sensitive sites were measured in the same experiment, indicating that the large spread in the latter lesions was the main reason for the reduced inter-laboratory variation. However, it remains worrying that half of the participating laboratories obtained...

  4. College quality and hourly wages: evidence from the self-revelation model, sibling models and instrumental variables.

    Science.gov (United States)

    Borgen, Nicolai T

    2014-11-01

    This paper addresses the recent discussion on confounding in the returns to college quality literature using the Norwegian case. The main advantage of studying Norway is the quality of the data. Norwegian administrative data provide information on college applications, family relations and a rich set of control variables for all Norwegian citizens applying to college between 1997 and 2004 (N = 141,319) and their succeeding wages between 2003 and 2010 (676,079 person-year observations). With these data, this paper uses a subset of the models that have rendered mixed findings in the literature in order to investigate to what extent confounding biases the returns to college quality. I compare estimates obtained using standard regression models to estimates obtained using the self-revelation model of Dale and Krueger (2002), a sibling fixed effects model and the instrumental variable model used by Long (2008). Using these methods, I consistently find increasing returns to college quality over the course of students' work careers, with positive returns only later in students' work careers. I conclude that the standard regression estimate provides a reasonable estimate of the returns to college quality. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. The design of management control systems in inter-organisational relationships in the Malaysian banking industry

    OpenAIRE

    Asudalli, Mohd Nordin

    2017-01-01

    This study examines the design of management control systems (MCS) in inter-organisational relationships (lOR). Adopting a contingency approach, the study aims to identify whether fit between lOR contextual variables and MCS design enhances lOR performance. This study conducted several statistical tests to examine the relationships between six lOR contextual variables and the design of MCS in lOR, and their effects on lOR performance. The contextual variables were buyer asset specificity,...

  6. Factors affecting inter-birth in rural areas of Zarrindasht (Fars province

    Directory of Open Access Journals (Sweden)

    Najaf Zare

    2015-01-01

    Full Text Available Background: Proper time intervals among pregnancies has a major role in family provision. Investigating the dynamism of the birth spacing, identify factors and their effects on the time interval among pregnancies and determination of optimal spacing is the utmost importance for health planners and families. The purpose was to study the abortion and stillbirth due to short inter-birth spacing, factors affecting inter-births and optimal birth spacing. Material and Methods: In 2005, a cross-sectional study was conducted in a population of 1064 women of childbearing age in Fars province by multistage random sampling. Information on reproductive history was collected by resident health workers. Variables affecting inter-births were checked by the frailty recurrent events model using S-plus 2000 and SPSS 13 software. Results: The rate of abortion or stillbirth was 1.7%, which fell with increasing interval between births and reached their lowest (1.9% at 36-48 months. Mother's level of education, duration of breastfeeding of previous infant, maternal age at birth and father's job showed positive correlation with inter-birth. Mother's age at marriage, having a job other than household, socioeconomic status was negatively correlated with the the time interval to the next delivery. With increasing birth order, inter-birth of each delivery with regard to previous delivery increased on average by one to two months. Conclusion: The risk of abortion and stillbirth were observed more in subsequent delivery with very low or very long gap interval.

  7. Instrumentation and process control for fossil demonstration plants. Quarterly technical progress report, April--June 1977

    Energy Technology Data Exchange (ETDEWEB)

    LeSage, L.G.

    1977-07-01

    Work has been performed on updating the study of the state-of-the-art of instrumentation for Fossil Demonstration Plants (FDP), development of mass-flow and other on-line instruments for FDP, process control analysis for FDP, and organization of a symposium on instrumentation and control for FDP. A Solids/Gas Flow Test Facility (S/GFTF) under construction for instrument development, testing, evaluation, and calibration is described. The development work for several mass-flow and other on-line instruments is described: acoustic flowmeter, capacitive density flowmeter, neutron activation flowmeter and composition analysis system, gamma ray correlation flowmeter, optical flowmeter, and capacitive liquid interface level meter.

  8. Instrumentation on commercial aircraft for monitoring the atmospheric composition on a global scale: the IAGOS system, technical overview of ozone and carbon monoxide measurements

    Directory of Open Access Journals (Sweden)

    Phillipe Nédélec

    2015-06-01

    Full Text Available This article presents the In-service Aircraft of a Global Observing System (IAGOS developed for operations on commercial long-range Airbus aircraft (A330/A340 for monitoring the atmospheric composition. IAGOS is the continuation of the former Measurement of OZone and water vapour on Airbus In-service airCraft (MOZAIC programme (1994–2014 with five aircraft operated by European airlines over 20 yr. MOZAIC has provided unique scientific database used worldwide by the scientific community. In continuation of MOZAIC, IAGOS aims to equip a fleet up to 20 aircraft around the world and for operations over decades. IAGOS started in July 2011 with the first instruments installed aboard a Lufthansa A340-300, and a total of six aircraft are already in operation. We present the technical aircraft system concept, with basic instruments for O3, CO, water vapour and clouds; and optional instruments for measuring either NOy, NOx, aerosols or CO2/CH4. In this article, we focus on the O3 and CO instrumentation while other measurements are or will be described in specific papers. O3 and CO are measured by optimised but well-known methods such as UV absorption and IR correlation, respectively. We describe the data processing/validation and the data quality control for O3 and CO. Using the first two overlapping years of MOZAIC/IAGOS, we conclude that IAGOS can be considered as the continuation of MOZAIC with the same data quality of O3 and CO measurements.

  9. Inter-annual variability of urolithiasis epidemic from semi-arid part of Deccan Volcanic Province, India: climatic and hydrogeochemical perspectives.

    Science.gov (United States)

    Kale, Sanjay S; Ghole, Vikram Shantaram; Pawar, N J; Jagtap, Deepak V

    2014-01-01

    Semi-arid Karha basin from Deccan Volcanic Province, India was investigated for inter-annual variability of urolithiasis epidemic. The number of reported urolith patient, weather station data and groundwater quality results was used to assess impact of geoenvironment on urolithiasis. Data of 7081 urolith patient were processed for epidemiological study. Gender class, age group, year-wise cases and urolith type were studied in epidemiology. Rainfall, temperature, pan evaporation and sunshine hours were used to correlate urolithiasis. Further, average values of groundwater parameters were correlated with the number of urolith episodes. A total of 52 urolith samples were collected from hospitals and analysed using FTIR technique to identify dominant urolith type in study area. Result shows that male population is more prone, age group of 20-40 is more susceptible and calcium oxalate uroliths are dominant in study area. Year-wise distribution revealed that there is steady increase in urolithiasis with inflation in drought years. In climatic parameters, hot days are significantly correlated with urolithiasis. In groundwater quality, EC, Na and F are convincingly correlated with urolith patients, which concludes the strong relation between geo-environment and urolithiasis.

  10. Standard Technical Specifications, Westinghouse Plants

    International Nuclear Information System (INIS)

    1992-09-01

    This NUREG contains improved Standard Technical Specifications (STS) for Westinghouse Plants and documents the positions of the Nuclear Regulatory Commission based on the Westinghouse Owners Group's proposed STS. This document is the result of extensive technical meetings and discussions among the NRC staff, the Nuclear Steam Supply System (NSSS) Owners Groups, the NSSS vendors, and the Nuclear Management and Resources Council (NUMARC). The improved STS were developed based on the criteria in the interim Commission Policy Statement on Technical Specification Improvements for Nuclear Power Reactors, dated February 6, 1987. The improved STS will be used as the basis for individual nuclear power plant licensees to develop improved plant-specific technical specifications. This report contains three volumes. Volume 1 contains the Specifications for all chapters and sections of the improved STS. Volume 2 contains the Bases for Chapters 2.0 and 3.0, and Sections 3.1--3.3 of the unproved STS. Volume 3 contains the Bases for Sections 3.4--3.9 of the improved STS which contain information on safety limits, reactivity control systems, power distribution limits, and instrumentation

  11. Inter-operator and inter-device agreement and reliability of the SEM Scanner.

    Science.gov (United States)

    Clendenin, Marta; Jaradeh, Kindah; Shamirian, Anasheh; Rhodes, Shannon L

    2015-02-01

    The SEM Scanner is a medical device designed for use by healthcare providers as part of pressure ulcer prevention programs. The objective of this study was to evaluate the inter-rater and inter-device agreement and reliability of the SEM Scanner. Thirty-one (31) volunteers free of pressure ulcers or broken skin at the sternum, sacrum, and heels were assessed with the SEM Scanner. Each of three operators utilized each of three devices to collect readings from four anatomical sites (sternum, sacrum, left and right heels) on each subject for a total of 108 readings per subject collected over approximately 30 min. For each combination of operator-device-anatomical site, three SEM readings were collected. Inter-operator and inter-device agreement and reliability were estimated. Over the course of this study, more than 3000 SEM Scanner readings were collected. Agreement between operators was good with mean differences ranging from -0.01 to 0.11. Inter-operator and inter-device reliability exceeded 0.80 at all anatomical sites assessed. The results of this study demonstrate the high reliability and good agreement of the SEM Scanner across different operators and different devices. Given the limitations of current methods to prevent and detect pressure ulcers, the SEM Scanner shows promise as an objective, reliable tool for assessing the presence or absence of pressure-induced tissue damage such as pressure ulcers. Copyright © 2015 Bruin Biometrics, LLC. Published by Elsevier Ltd.. All rights reserved.

  12. The first Swedish nuclear reactor - from technical prototype to scientific instrument; Sveriges foersta kaernreaktor - fraan teknisk prototyp till vetenskapligt instrument

    Energy Technology Data Exchange (ETDEWEB)

    Fjaestad, M. [Royal Inst. of Tech., Stockholm (Sweden). Dept. of History of Science and Technology

    2001-01-01

    The first Swedish reactor R1, constructed at the Royal Inst. of Technology in Stockholm, went critical in July 1954. This report presents historical aspects of the reactor, in particular about the reactor as a research instrument and a centre for physical science. The tensions between its role as a prototype and a step in the development of power reactors and that as a scientific instrument are especially focused.

  13. 1st Advanced Marine Renewable Energy Instrumentation Experts Workshop: April 5-7, 2011

    International Nuclear Information System (INIS)

    2011-01-01

    The U.S. marine energy industry is actively pursuing development of offshore wind and marine hydrokinetic (MHK) energy systems. Experience in the wind energy sector demonstrates that new technology development requires thorough measurement and characterization of the environmental conditions prevalent at installation sites and of technology operating in the field. Presently, there are no turn-key instrumentation system solutions that meet the measurement needs of the marine energy industry. The 1st Advanced Marine Renewable Energy Instrumentation Experts Workshop brought together technical experts from government laboratories, academia, and industry representatives from marine energy, wind, offshore oil and gas, and instrumentation developers to present and discuss the instrumentation needs of the marine energy industry. The goals of the meeting were to: (1) Share the latest relevant knowledge among technical experts; (2) Review relevant state-of-the-art field measurement technologies and methods; (3) Review lessons learned from recent field deployments; (4) Identify synergies across different industries; (5) Identify gaps between existing and needed instrumentation capabilities; (6) Understand who are the leading experts; (7) Provide a forum where stakeholders from the marine energy industry could provide substantive input in the development of new marine energy field deployable instrumentation packages.

  14. 1st Advanced Marine Renewable Energy Instrumentation Experts Workshop: April 5-7, 2011

    Energy Technology Data Exchange (ETDEWEB)

    2011-10-01

    The U.S. marine energy industry is actively pursuing development of offshore wind and marine hydrokinetic (MHK) energy systems. Experience in the wind energy sector demonstrates that new technology development requires thorough measurement and characterization of the environmental conditions prevalent at installation sites and of technology operating in the field. Presently, there are no turn-key instrumentation system solutions that meet the measurement needs of the marine energy industry. The 1st Advanced Marine Renewable Energy Instrumentation Experts Workshop brought together technical experts from government laboratories, academia, and industry representatives from marine energy, wind, offshore oil and gas, and instrumentation developers to present and discuss the instrumentation needs of the marine energy industry. The goals of the meeting were to: (1) Share the latest relevant knowledge among technical experts; (2) Review relevant state-of-the-art field measurement technologies and methods; (3) Review lessons learned from recent field deployments; (4) Identify synergies across different industries; (5) Identify gaps between existing and needed instrumentation capabilities; (6) Understand who are the leading experts; (7) Provide a forum where stakeholders from the marine energy industry could provide substantive input in the development of new marine energy field deployable instrumentation packages.

  15. Inter-Annual Variability of Fledgling Sex Ratio in King Penguins.

    Directory of Open Access Journals (Sweden)

    Célia Bordier

    Full Text Available As the number of breeding pairs depends on the adult sex ratio in a monogamous species with biparental care, investigating sex-ratio variability in natural populations is essential to understand population dynamics. Using 10 years of data (2000-2009 in a seasonally monogamous seabird, the king penguin (Aptenodytes patagonicus, we investigated the annual sex ratio at fledging, and the potential environmental causes for its variation. Over more than 4000 birds, the annual sex ratio at fledging was highly variable (ranging from 44.4% to 58.3% of males, and on average slightly biased towards males (51.6%. Yearly variation in sex-ratio bias was neither related to density within the colony, nor to global or local oceanographic conditions known to affect both the productivity and accessibility of penguin foraging areas. However, rising sea surface temperature coincided with an increase in fledging sex-ratio variability. Fledging sex ratio was also correlated with difference in body condition between male and female fledglings. When more males were produced in a given year, their body condition was higher (and reciprocally, suggesting that parents might adopt a sex-biased allocation strategy depending on yearly environmental conditions and/or that the effect of environmental parameters on chick condition and survival may be sex-dependent. The initial bias in sex ratio observed at the juvenile stage tended to return to 1∶1 equilibrium upon first breeding attempts, as would be expected from Fisher's classic theory of offspring sex-ratio variation.

  16. Inter-Annual Variability of Fledgling Sex Ratio in King Penguins.

    Science.gov (United States)

    Bordier, Célia; Saraux, Claire; Viblanc, Vincent A; Gachot-Neveu, Hélène; Beaugey, Magali; Le Maho, Yvon; Le Bohec, Céline

    2014-01-01

    As the number of breeding pairs depends on the adult sex ratio in a monogamous species with biparental care, investigating sex-ratio variability in natural populations is essential to understand population dynamics. Using 10 years of data (2000-2009) in a seasonally monogamous seabird, the king penguin (Aptenodytes patagonicus), we investigated the annual sex ratio at fledging, and the potential environmental causes for its variation. Over more than 4000 birds, the annual sex ratio at fledging was highly variable (ranging from 44.4% to 58.3% of males), and on average slightly biased towards males (51.6%). Yearly variation in sex-ratio bias was neither related to density within the colony, nor to global or local oceanographic conditions known to affect both the productivity and accessibility of penguin foraging areas. However, rising sea surface temperature coincided with an increase in fledging sex-ratio variability. Fledging sex ratio was also correlated with difference in body condition between male and female fledglings. When more males were produced in a given year, their body condition was higher (and reciprocally), suggesting that parents might adopt a sex-biased allocation strategy depending on yearly environmental conditions and/or that the effect of environmental parameters on chick condition and survival may be sex-dependent. The initial bias in sex ratio observed at the juvenile stage tended to return to 1∶1 equilibrium upon first breeding attempts, as would be expected from Fisher's classic theory of offspring sex-ratio variation.

  17. Impact of educational intervention on the inter-rater agreement of nasal endoscopy interpretation

    Science.gov (United States)

    Colley, Patrick; Mace, Jess C.; Schaberg, Madeleine R.; Smith, Timothy L.; Tabaee, Abtin

    2015-01-01

    OBJECTIVE Nasal endoscopy is integral to the evaluation of sinonasal disorders. However, prior studies have shown significant variability in the inter-rater agreement of nasal endoscopy interpretation amongst practicing rhinologists. The objective of the current study is to evaluate the inter-rater agreement of nasal endoscopy amongst otolaryngology residents from a single training program at baseline and following an educational intervention. METHODS 11 otolaryngology residents completed nasal endoscopy grading forms for 8 digitally recorded nasal endoscopic examinations. An instructional lecture reviewing nasal endoscopy interpretation was subsequently provided. The residents then completed grading forms for 8 different nasal endoscopic examinations. Inter-rate agreement amongst residents for the pre- and post-lecture videos was calculated using the unweighted Fleiss’ kappa statistic (Kf) and intra-class correlation agreement (ICC). RESULTS Inter-rater agreement improved from a baseline level of fair (Kf range 0.268–0.383) to a post-educational level of moderate (Kf range 0.401–0.547) for nasal endoscopy findings of middle meatus mucosa, middle turbinate mucosa, middle meatus discharge, sphenoethmoid recess mucosa, sphenoethmoid recess discharge and atypical lesions (ICC, pendoscopy interpretation amongst otolaryngology residents. The inter-rater agreement for the majority of the characteristics that were evaluated improved after educational intervention. Further study is needed to improve nasal endoscopy interpretation. PMID:25781864

  18. Inter- and intra-host viral diversity in a large seasonal DENV2 outbreak.

    Directory of Open Access Journals (Sweden)

    Camila Malta Romano

    Full Text Available BACKGROUND: High genetic diversity at both inter- and intra-host level are hallmarks of RNA viruses due to the error-prone nature of their genome replication. Several groups have evaluated the extent of viral variability using different RNA virus deep sequencing methods. Although much of this effort has been dedicated to pathogens that cause chronic infections in humans, few studies investigated arthropod-borne, acute viral infections. METHODS AND PRINCIPAL FINDINGS: We deep sequenced the complete genome of ten DENV2 isolates from representative classical and severe cases sampled in a large outbreak in Brazil using two different approaches. Analysis of the consensus genomes confirmed the larger extent of the 2010 epidemic in comparison to a previous epidemic caused by the same viruses in another city two years before (genetic distance = 0.002 and 0.0008 respectively. Analysis of viral populations within the host revealed a high level of conservation. After excluding homopolymer regions of 454/Roche generated sequences, we found 10 to 44 variable sites per genome population at a frequency of >1%, resulting in very low intra-host genetic diversity. While up to 60% of all variable sites at intra-host level were non-synonymous changes, only 10% of inter-host variability resulted from non-synonymous mutations, indicative of purifying selection at the population level. CONCLUSIONS AND SIGNIFICANCE: Despite the error-prone nature of RNA-dependent RNA-polymerase, dengue viruses maintain low levels of intra-host variability.

  19. Transcultural Adaptation of GRID Hamilton Rating Scale For Depression (GRID-HAMD) to Brazilian Portuguese and Evaluation of the Impact of Training Upon Inter-Rater Reliability.

    Science.gov (United States)

    Henrique-Araújo, Ricardo; Osório, Flávia L; Gonçalves Ribeiro, Mônica; Soares Monteiro, Ivandro; Williams, Janet B W; Kalali, Amir; Alexandre Crippa, José; Oliveira, Irismar Reis De

    2014-07-01

    GRID-HAMD is a semi-structured interview guide developed to overcome flaws in HAM-D, and has been incorporated into an increasing number of studies. Carry out the transcultural adaptation of GRID-HAMD into the Brazilian Portuguese language, evaluate the inter-rater reliability of this instrument and the training impact upon this measure, and verify the raters' opinions of said instrument. The transcultural adaptation was conducted by appropriate methodology. The measurement of inter-rater reliability was done by way of videos that were evaluated by 85 professionals before and after training for the use of this instrument. The intraclass correlation coefficient (ICC) remained between 0.76 and 0.90 for GRID-HAMD-21 and between 0.72 and 0.91 for GRID-HAMD-17. The training did not have an impact on the ICC, except for a few groups of participants with a lower level of experience. Most of the participants showed high acceptance of GRID-HAMD, when compared to other versions of HAM-D. The scale presented adequate inter-rater reliability even before training began. Training did not have an impact on this measure, except for a few groups with less experience. GRID-HAMD received favorable opinions from most of the participants.

  20. Validation of an instrumented dummy to assess mechanical aspects of discomfort during load carriage.

    Directory of Open Access Journals (Sweden)

    Patrick D Wettenschwiler

    Full Text Available Due to the increasing load in backpacks and other load carriage systems over the last decades, load carriage system designs have to be adapted accordingly to minimize discomfort and to reduce the risk of injury. As subject studies are labor-intensive and include further challenges such as intra-subject and inter-subject variability, we aimed to validate an instrumented dummy as an objective laboratory tool to assess the mechanical aspects of discomfort. The validation of the instrumented dummy was conducted by comparison with a recent subject study. The mechanical parameters that characterize the static and dynamic interaction between backpack and body during different backpack settings were compared. The second aim was to investigate whether high predictive power (coefficient of determination R2>0.5 in assessing the discomfort of load carriage systems could be reached using the instrumented dummy. Measurements were conducted under static conditions, simulating upright standing, and dynamic conditions, simulating level walking. Twelve different configurations of a typical load carriage system, a commercially available backpack with a hip belt, were assessed. The mechanical parameters were measured in the shoulder and the hip region of the dummy and consisted of average pressure, peak pressure, strap force and relative motion between the system and the body. The twelve configurations consisted of three different weights (15kg, 20kg, and 25kg, combined with four different hip belt tensions (30N, 60N, 90N, and 120N. Through the significant (p<0.05 correlation of the mechanical parameters measured on the dummy with the corresponding values of the subject study, the dummy was validated for all static measurements and for dynamic measurements in the hip region to accurately simulate the interaction between the human body and the load carriage system. Multiple linear regressions with the mechanical parameters measured on the dummy as independent