WorldWideScience

Sample records for technetium-99m sulfur colloid

  1. Clinical significance of /sup 99m/technetium sulfur colloid accumulation in renal transplant patients

    International Nuclear Information System (INIS)

    Kim, Y.C.; Massari, P.U.; Brown, M.L.; Thrall, J.H.; Chang, B.; Keyes, J.W. Jr.

    1977-01-01

    The accumulation of /sup 99m/technetium sulfur colloid (/sup 99m/TcSC) was evaluated in 47 studies performed on 19 renal transplant patients by comparing its transplant activity to its bone marrow accumulation. There was a diagnosis of rejection in 21 of 22 studies (96.5 percent) in which marked transplant accumulation was noted. In 11 studies of patients with a clinical diagnosis of post-transplant acute tubular necrosis (ATN), the transplant activity varied from none to moderate. Rejection developed in 5 of 6 studies with minimal to moderate accumulation. Normally functioning renal transplant patients, or those with ATN and no superimposed rejection, do not show evidence of /sup 99m/TcSC accumulation

  2. Extramedullary pulmonary hematopoiesis causing pulmonary hypertension and severe tricuspid regurgitation detected by 99m technetium sulfur colloid bone marrow scan and single-photon emission computed tomography/CT

    International Nuclear Information System (INIS)

    Ali, Syed Zama; Clarke, Michael John; Kannivelu, Anbalagan; Chinchure, Dinesh; Srinivasan, Sivasubramanian

    2014-01-01

    Extramedullary pulmonary hematopoiesis is a rare entity with a limited number of case reports in the available literature only. We report the case of a 66-year-old man with known primary myelofibrosis, in whom a 99m technetium sulfur colloid bone marrow scan with single-photon emission computed tomography (SPECT)/CT revealed a pulmonary hematopoiesis as the cause of pulmonary hypertension and severe tricuspid regurgitation. To the best of our knowledge, this is the first description of 99m technetium sulfur colloid SPECT/CT imaging in this rare condition.

  3. Extramedullary pulmonary hematopoiesis causing pulmonary hypertension and severe tricuspid regurgitation detected by {sup 99m} technetium sulfur colloid bone marrow scan and single-photon emission computed tomography/CT

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Syed Zama; Clarke, Michael John; Kannivelu, Anbalagan; Chinchure, Dinesh; Srinivasan, Sivasubramanian [Dept. of Diagnostic Radiology, Khoo Teck Puat Hospital, Singapore (Singapore)

    2014-06-15

    Extramedullary pulmonary hematopoiesis is a rare entity with a limited number of case reports in the available literature only. We report the case of a 66-year-old man with known primary myelofibrosis, in whom a {sup 99m}technetium sulfur colloid bone marrow scan with single-photon emission computed tomography (SPECT)/CT revealed a pulmonary hematopoiesis as the cause of pulmonary hypertension and severe tricuspid regurgitation. To the best of our knowledge, this is the first description of {sup 99m} technetium sulfur colloid SPECT/CT imaging in this rare condition.

  4. Comparison of technetium-99m sulfur colloid and technetium-99m albumin colloid labeled solid meals for gastric emptying studies.

    Science.gov (United States)

    Taillefer, R; Douesnard, J M; Beauchamp, G; Guimond, J

    1987-08-01

    A Tc-99m albumin colloid (Tc-AC) kit has been introduced as an alternative to Tc-99m sulfur colloid (Tc-SC) for liver-spleen imaging. Since there is no need for boiling, the use of Tc-AC reduces preparation time and manipulation. Tc-SC is one of the most commonly used radiopharmaceuticals for the labeling of solid-phase markers in gastric emptying studies. In vitro studies were performed to evaluate the labeling efficiency and stability in hydrochloric acid and in human gastric juice of intracellularly labeled chicken liver and scrambled eggs labeled with Tc-SC and Tc-AC. Gastric emptying studies also were performed on 20 healthy volunteers with both Tc-SC and Tc-AC labeled scrambled egg sandwiches. There was no significant difference between Tc-SC and Tc-AC in the labeling efficiency of chicken liver (98% +/- 1% for Tc-SC, 96% +/- 2% for Tc-AC) and scrambled eggs (92% +/- 2% for Tc-SC, 91% +/- 3% for Tc-AC). However, both Tc-SC and Tc-AC labeled scrambled eggs showed a lower stability than chicken liver, particularly in human gastric juice. Gastric emptying curves from both meals in 20 normal subjects were also similar, with a mean half-emptying time of 85 +/- 13 minutes and 87 +/- 16 minutes for the meals containing Tc-SC and Tc-AC respectively. Tc-AC is a reliable alternative to Tc-SC as a radiotracer for solid-phase gastric emptying studies.

  5. Biomedical tracers: technetium-99 m complexing sulfur polydentate ligands

    International Nuclear Information System (INIS)

    Bendennoune, A.

    1994-01-01

    Cyclic and acyclic tetra sulfur ligands have been synthesized and some of them have been labelled with technetium-99m. These works have two different aims: 1- Development of methods permitting to obtain easily potential technetium complexing sulfur polydentate chelates. 2- Research of positive and neutral complexes of this metal likely to replace thalium-201 in the coronary flow estimation and [TcO-HMPAO] sup 0 complex in the cerebral scintigraphy, respectively. In this work, first, different ways for obtaining dithioetherdithiols and cyclic tetrathioethers containing functional groups have been carried out, then complexation of the core of nitrutechnetium (TcN) sup 2+ at tracers scale, by dithioetherdithiols, using exchange reaction with [sup 9 sup 9 sup m TcNCl sub 4 ] sup - ion complex or sup 99 sup m TcN Cl sub 2 [P(CH sub 2 CH sub 2 CN) sub 3 ] sub 2 has been studied. Finally, biological distribution in swiss mouse of these technetiated complexes has been studied. 135 refs., 30 figs., 13 tabs. (F.M.)

  6. Hot spot(s) of the lung in technetium-99m albumin colloid liver-spleen scintigraphy: case report

    International Nuclear Information System (INIS)

    Shih, W.J.; Brandenburg, S.; Coupal, J.J.; Sullivan, J.D.; Beeler, J.A.; Magoun, S.; Ryo, U.Y.

    1988-01-01

    The authors replaced /sup 99m/Tc albumin colloid for /sup 99m/Tc sulfur colloid as a radiopharmaceutical for liver-spleen imaging and found two instances of hot spot(s) in the lung. The preparation procedure of albumin colloid is easier and more convenient as compared to that of sulfur colloid. Whereas replacement of /sup 99m/Tc sulfur colloid by /sup 99m/Tc albumin colloid is inevitable, it should be emphasized that one should avoid blood withdrawal in the syringe containing albumin colloid to prevent formation of clot(s) during the venous puncture for /sup 99m/Tc albumin colloid

  7. Localization of hemorrhage in a recurrent hemothorax using Tc-99m-sulfur colloid

    International Nuclear Information System (INIS)

    Taillefer, R.; Essiambre, R.; Lemieux, R.

    1981-01-01

    Tc99m-sulfur colloid scintigraphy has proven clinically useful in identifying gastrointestinal hemorrhages. The authors describe a patient with recurrent hemothorax under oral anticoagulation therapy in which Tc-99m-sulfur colloid imaging was used to determine the site of bleeding

  8. Study of technetium behaviour in radiopharmaceuticals. Characterization of sup(99m)Tc-pyrophosphate, sup(99m)Tc-dimercaptosuccinate, sup(99m)Tc-diethylenetriaminepentaacetate complexes and sup(99m)Tc-colloidal rhenium sulphide

    International Nuclear Information System (INIS)

    Saccavini, J.-C.

    1980-12-01

    The chemistry of technetium in extremely dilute solution was approached through the study of three complexing agents and a colloid. By the application of high-performance chromatographic techniques to the analysis of (Tc-pyro), (Tc-DTPA), (Tc-DMSA) complexes it was possible to isolate one or more chelates from a single complexing agent. Addition of pertechnetates to a solution of sodium pyrophosphates and stannous chloride at neutral pH leads to the formation of two complexes, both highly osteotropic. By the use of sup(117m)Sn it was shown that tin employed as reducing agent enters into the composition of one of the two complexes, either of which may be obtained preferentially by varying the (Sn)/(pyro) ratio. With technetium at acid pH (2.5) DMSA gives one or more chelates according to the concentration of the reagents present. DTPA with technetium at neutral pH gives a single complex for which a structure is proposed. The addition of calcium, indispensable for DTPA injection, leads to the appearance of a second bimetallic complex in very much smaller proportions than the first. The size distribution of some colloids was studied by ultrafiltration and permeation on gel. The preparation of colloidal rhenium sulphide and the technetium labelling conditions needed to obtain a very fine colloid were developed. The behaviour of technetium in the presence of colloidal rhenium sulphide and tin pyrophosphate was followed by sup(99m)Tc - sup(186)Re and sup(99m)Tc - sup(117m)Sn double-labelling tests. One reduced technetium fraction associates with the hydrolysed tin, the other follows the rhenium sulphide [fr

  9. Methods for the quality control of macroaggregates and colloids labelled with technetium-99m. Part of a coordinated programme on radiopharmaceuticals

    International Nuclear Information System (INIS)

    Cifka, J.

    1975-09-01

    Comprehensive studies of the antimony sulphide and sulphur colloids labelled with sup(99m)Tc was performed by the authors. Similar studies dealing with human serum albumin macroaggregates labelled with sup(99m)Tc were also initiated. The labelling processes were studied to determine the possible chemical forms of technetium-99m not bound to the colloidal particles. It was found that pertechnetate-99m is not the only possible impurity in the case of the colloids. Technetium-99m may be present as an soluble tartrate complex in the case of antimony sulphide colloid or as a soluble chlorocomplex in the case of the sulphur colloid. Techniques for the control of these colloids were developed. A method for the determination of particle size of the sulphur colloid is also described

  10. Intraperitoneal injection of technetium-99m sulfur colloid in visualization of a peritoneo-vaginalis connection

    International Nuclear Information System (INIS)

    Ducassou, D.; Vuillemin, L.; Wone, C.; Ragnaud, J.M.; Brendel, A.J.

    1984-01-01

    Ten minutes after an intraperitoneal infusion of Tc-99m sulfur colloid, a gamma camera was used to obtain anterior abdominal views. This visualized a peritoneo-scrotal communication in an 80-yr-old patient. He had developed extensive edema of the genitals and lower limbs after about 6 wk of continuous ambulatory peritoneal dialysis. At operation the communication was confirmed and closed. A repeat test verified the success of operation

  11. Imaging of irradiated liver with Tc-99m-sulfur colloid and Tc-99m-IDA

    International Nuclear Information System (INIS)

    Gelfand, M.J.; Saha, S.; Aron, B.S.

    1981-01-01

    In three cases, irradiated regions of liver failed to concentrate Tc-99m-sulfur colloid. In two of these three, imaging with Tc-99m-acetanilide iminodiacetic acid (IDA) agents within five days showed near normal hepatic uptake of this hepatobiliary imaging agent. The hepatic parenchymal cells may be imaged with Tc-99m-IDA in some irradiated regions of liver, despite loss of reticuloendothelial cell function

  12. Investigation of space-occupying lesions in the liver with technetium-99m tin colloid and indium-113m-chloride

    International Nuclear Information System (INIS)

    Nelson, M.J.; Klopper, J.F.

    1985-01-01

    Liver scanning with radiocolloids is an important method to determine the presence, the position and the size of space-occupying lesions in the liver. Unfortunately, this information is nonspecific and it is not possible to distinguish between tumours, abscesses or cysts. Thirty-six patients in whom a definite diagnosis of hepatoma, amoebic liver abscess or echinococcus cyst had been made were examined with technetium-99m tin colloid and indium-113m chloride. The amoebic liver abscesses were avascular, showed a hyperaemic area surrounding the abscess and appeared smaller on the indium than on the technetium scan. The hepatomas showed greater vascularity and absence of the hyperaemic area. Cysts were avascular, did not show a hyperaemic rim and the size was equal on both scans. The experience of the observers had an influence on the accuracy of interpretation of the scans; experienced observers made a correct diagnosis in 73% of cases. It is suggested that simultaneous technetium-99m tin colloid and indium 113m-chloride scans provide additional specificity in the differential diagnosis between hepatoma, amoebic liver abscess and echinococcus cysts

  13. Investigation of space-occupying lesions in the liver with technetium-99m tin colloid and indium-113m-chloride

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, M.J. (Provincial Hospital, Port Elizabeth (South Africa). Dept. of Nuclear Medicine); Klopper, J.F. (Stellenbosch Univ. (South Africa). Dept. of Nuclear Medicine)

    1985-01-26

    Liver scanning with radiocolloids is an important method to determine the presence, the position and the size of space-occupying lesions in the liver. Unfortunately, this information is nonspecific and it is not possible to distinguish between tumours, abscesses or cysts. Thirty-six patients in whom a definite diagnosis of hepatoma, amoebic liver abscess or echinococcus cyst had been made were examined with technetium-99m tin colloid and indium-113m chloride. The amoebic liver abscesses were avascular, showed a hyperaemic area surrounding the abscess and appeared smaller on the indium than on the technetium scan. The hepatomas showed greater vascularity and absence of the hyperaemic area. Cysts were avascular, did not show a hyperaemic rim and the size was equal on both scans. The experience of the observers had an influence on the accuracy of interpretation of the scans; experienced observers made a correct diagnosis in 73% of cases. It is suggested that simultaneous technetium-99m tin colloid and indium 113m-chloride scans provide additional specificity in the differential diagnosis between hepatoma, amoebic liver abscess and echinococcus cysts.

  14. Tc-99m sulfur colloid scanning in blunt trauma: detection of abdominal bleeding

    International Nuclear Information System (INIS)

    Bronfman, H.J.; Kunkel, B.K.; Rabin, H.S.

    1981-01-01

    Tc-99m sulfur colloid scintigraphy can detect and locate active lower gastrointestinal bleeding. The same principles apply to the detection and location of active intra-abdominal or pelvic hemorrhage following blunt abdominal trauma. We report two patients with abdominal bleeding who were correctly diagnosed by this method. As part of the routine examination of all patients having Tc-99m sulfur colloid liver-spleen scans for trauma, 500,000-count images should be made of the rest of the abdomen and pelvis

  15. Assessment of gastric motility using meal labeled with technetium-99m sulfur colloid

    International Nuclear Information System (INIS)

    Matolo, N.M.; Stadalnik, R.C.

    1983-01-01

    During a 2 year period, 83 patients with gastric motility problems were evaluated using radionuclide imaging. The patients presented with epigastric distress, postprandial fullness, pain, nausea, vomiting, and diarrhea; signs and symptoms suggestive of either gastroparesis or gastric outlet obstruction. Upper gastrointestinal series or endoscopy, or both, demonstrated no mechanical obstruction. After oral administration of a 300 g meal labeled with 600 muCi of technetium-99m sulfur colloid, a gastric emptying study consisting of serial images and data acquisition was performed. Of the patients studied, 52 had had peptic ulcer surgery, 17 were suspected of having gastroesophageal reflux, 8 were diabetic and suspected of having visceral enteropathy, and 6 had a history of irritable bowel syndrome. The normal mean gastric half emptying time was 77 +/- 16 minutes. Of the patients who had had gastric surgery, 90.4 percent had abnormal emptying: 69.2 percent had delayed gastric emptying and 21.2 percent had rapid gastric emptying time; 9.6 percent had normal emptying time. Of the gastroesophageal reflux group, all but two had normal gastric emptying time; 65 percent demonstrated gastroesophageal reflux within 15 minutes. Two of the patients with irritable bowel syndrome had prolonged emptying; the rest had normal emptying. All diabetic patients with gastroparesis had prolonged gastric emptying time, and all responded favorably to metoclopramide. Of the patients who previously had peptic ulcer surgery and had prolonged emptying time, 72 percent also responded favorably to metoclopramide. We conclude that radionuclide gastric imaging is a useful diagnostic test for the measurement of gastric emptying in patients with a variety of gastrointestinal motility disorders and may be helpful in assessing medical therapy and selecting those who may be candidates for surgery

  16. Dose to the liver and spleen in pediatric patients undergoing technetium-99m sulfur colloid scans

    International Nuclear Information System (INIS)

    Thomas, S.R.; Purdom, R.C.; Kereiakes, J.G.; Gelfand, M.J.; Maxon, H.R.

    1979-01-01

    Quantitative conjugate view external counting techniques were applied to determine radiation dose to the liver and spleen in pediatric patients undergoing /sup 99m/Tc-sulfur colloid (Tc-SC) liver scans. The effective half-life of /sup99m/Tc-SC was 5.8 +- 0.23 hours and 5.2 +- 0.68 hours in the liver and spleen, respectively. Dose per administered activity ranged from 0.34 to 0.63 rad/mCi (92 to 170 μGy/MBq) for the liver and 0.35 to 1.96 rad/mCi (95.0 to 530.0 μGy/MBq) for the spleen. The spleen to liver dose ratio ranged from 1.0 to 4.9. These values are compared with results extrapolated from published adult data to the pediatric population

  17. Ventilation scintigraphy of the lung with sup(99m)Tc-DTPA or with sup(99m)Tc-sulfur colloid

    Energy Technology Data Exchange (ETDEWEB)

    Koehler, D; Matthys, H; Coates, G; Dolovich, M; Newhouse, M

    1983-04-01

    Ventilation scintigraphy of the lung, obtained with sufficiently small sup(99m)Tc-labelled aerosol particles, provides an image of ventilation distribution that is acceptable in clinical routine. Whether sup(99m)Tc-DTPA or sup(99m)Tc-sulfur colloid is more suitable as a carrier was studied in 6 smokers and 8 non-smokers with chronic obstructive pulmonary disease. sup(99m)Tc-sulfur colloid was not absorbed by the bronchial mucosa and therefore appears to be an almost ideal agent. In contrast, sup(99m)Tc-DTPA was absorbed by the bronchial mucosa in all smoking patients more rapidly and inhomogenously than in non-smokers. The quantitative and qualitative comparison of the two dorsal ventilation scans taken both immediately after inhalation and 20 min later, showed in all 6 smoking patients after 20 min significant differences which influenced the diagnostic result. sup(99m)Tc-DTPA is therefore not recommended for use in ventilation lung scintigraphy, especially in smoking patients.

  18. Comparative evaluation of renal transplant rejection with radioiodinated fibrinogen, /sup 99m/Tc--sulfur colloid, and 67Ga-citrate

    International Nuclear Information System (INIS)

    George, E.A.; Codd, J.E.; Newton, W.T.; Haibach, H.; Donati, R.M.

    1976-01-01

    The diagnostic accuracy, ease, and technical feasibility of imaging with 131 I- or 125 I-fibrinogen, 99 /sup m/Tc-sulfur colloid, and 67 Ga-citrate in renal transplant rejection are compared. Radiofibrinogen data resulted from literature review, radio-colloid data from 125 studies in 52 transplant patients, and gallium citrate data from 24 examinations in seven renal transplant patients performed simultaneously with the radiocolloid studies. Specificity of graft labeling during rejection appears to be similar with radiofibrinogen, 99 /sup m/Tc-sulfur colloid, and 67 Ga-citrate. For routine clinical use 99 /sup m/Tc-sulfur colloid surpasses radiofibrinogen and radiogallium because of its better imaging qualities with a permissible radiation dose, leading to better separation of positive and negative results. The 99 /sup m/Tc-sulfur colloid accumulates in areas of intravascular fibrin thrombosis in acute and chronic rejecting renal transplants. Hence, the mechanisms for accumulation of 99 /sup m/Tc-sulfur colloid and labeled fibrinogen in rejecting transplants would seem to be similar. Such physiologic properties as rapid blood clearance and such physical properties as short physical half-life combine to produce reliable graft visualization with adequate definition, thus favoring 99 /sup m/Tc-sulfur colloid as the single agent of choice for clinical evaluation of renal transplant rejection at this time

  19. Studies of bone marrow scintigrams with sup(99m)technetium sulfur colloid on various hematological disorders

    International Nuclear Information System (INIS)

    Mizuno, Takashi

    1984-01-01

    One hundred and eighty-five bone marrow scintigraphy on the whole body was performed on eight healthy adults and 151 patients with various hematologic diseases including 64 leukemia, 41 anemia, 23 other malignancy, etc. The positions of the investigated bone marrow were divided into the central marrow (five positions on the trunk bones) and the peripheral marrow (11 positions on the upper and 11 positions on the lower extremities) on the scintigram. The bone marrow scintigram was estimated by following three criteria. The first, ''Yuu-ryoiki'' (positive area), was the existence of sup(99m)Tc sulfur colloid accumulation on bone marrow (two grades; presence or absence). The second, ''Bunpu-kei'' (distribution form), was the extent of the sup(99m)Tc accumulation area of the investigated bone marrow and was divided into five grades. The last, ''Kido'' (intensity of radioactivity), was the density of the sup(99m)Tc accumulation on the area and was divided into five grades. Using this estimation, in the diseases with bone marrow hyperplasia such as Primary Thrombocythemia and Hemolytic Anemia, ''Yuu-ryoiki'' was enlarged, ''Bunpu-kei'' was extended, and ''Kido'' was increased comparing with those in healty adult. In contrast, in the diseases with bone marrow hypoplasia such as Myelofibrosis and Aplastic Anemia, ''Yuu-ryoiki'' was reduced, ''Bunpu-kei'' was contracted, and ''Kido'' was decreased. However, the enlargement of ''Yuu-ryoiki'' did not always mean bone marrow hyperplasia. The author could evaluate not only the range and distribution of hemopoiesis as a whole in malignant or benign diseases but also the residual effective hemopoiesis to know the suitable time of the initiation of the therapy or to predict the prognosis of these cases. In this study it was shown that the bone marrow scintigraphy with sup(99m)Tc sulfur colloid was an useful method to estimate the hemopoietic activity of the bone marrow. (J.P.N.)

  20. Studies of bone marrow scintigrams with sup(99m)technetium sulfur colloid on various hematological disorders

    Energy Technology Data Exchange (ETDEWEB)

    Mizuno, Takashi (Hiroshima Univ. (Japan). Research Inst. for Nuclear Medicine and Biology)

    1984-02-01

    One hundred and eighty-five bone marrow scintigraphy on the whole body was performed on eight healthy adults and 151 patients with various hematologic diseases including 64 leukemia, 41 anemia, 23 other malignancy, etc. The positions of the investigated bone marrow were divided into the central marrow (five positions on the trunk bones) and the peripheral marrow (11 positions on the upper and 11 positions on the lower extremities) on the scintigram. The bone marrow scintigram was estimated by following three criteria. The first, ''Yuu-ryoiki'' (positive area), was the existence of sup(99m)Tc sulfur colloid accumulation on bone marrow (two grades; presence or absence). The second, ''Bunpu-kei'' (distribution form), was the extent of the sup(99m)Tc accumulation area of the investigated bone marrow and was divided into five grades. The last, ''Kido'' (intensity of radioactivity), was the density of the sup(99m)Tc accumulation on the area and was divided into five grades. Using this estimation, in the diseases with bone marrow hyperplasia such as Primary Thrombocythemia and Hemolytic Anemia, ''Yuu-ryoiki'' was enlarged, ''Bunpu-kei'' was extended, and ''Kido'' was increased comparing with those in healthy adult. In contrast, in the diseases with bone marrow hypoplasia such as Myelofibrosis and Aplastic Anemia, ''Yuu-ryoiki'' was reduced, ''Bunpu-kei'' was contracted, and ''Kido'' was decreased. However, the enlargement of ''Yuu-ryoiki'' did not always mean bone marrow hyperplasia. The author could evaluate not only the range and distribution of hemopoiesis as a whole in malignant or benign diseases but also the residual effective hemopoiesis to know the suitable time of the initiation of the therapy or to predict the prognosis of these cases. In this study it was shown

  1. sup(99m)Tc-sulfur-rhenium-colloid and 111In-indiumcitrate in the bone marrow scintigraphy

    International Nuclear Information System (INIS)

    Glaubitt, D.; Haberland, K.; Knoch, K.; Fejer, F.L.; Zachariah, S.; Staedtische Krankenanstalten Krefeld

    1975-01-01

    Bone marrow scintigraphy using 111 In-Indium-citrate and sup(99m)Tc-sulfur rhenium colloid was compared with each other in 6 male and 3 female patients. Our results in all patients were in favour of 111 In-citrate which caused a better delineation of morphological details than sup(99m)Tc-sulfur rhenium colloid did. In the first days after intravenous administration of 111 In-citrate, radioindium accumulated markedly in the pudendal region, this finding being more distinct in male patients than in female ones. On account of these results a considerable radiation dose has to be assumed in bone marrow scintigraphy using 111 In-citrate as long as the absorbed dose from 111 In has not been estimated under consideration of the radioindium accumulation in the pudendal region. 111 In-citrate should be applied in bone marrow scanning only exceptionally and sup(99m)Tc-sulfur rhenium colloid be preferred in the routine diagnostics of bone marrow. (orig.) [de

  2. Relative uptake of technetium 99m stannous colloid by neutrophils and monocytes is altered by gram-negative infection

    International Nuclear Information System (INIS)

    Ramsay, Stuart C.; Maggs, Jacqueline A.; Ketheesan, Natkunam; Norton, Robert; LaBrooy, Justin

    2005-01-01

    Gram-negative infection alters phagocytic cell function; hence, it could affect phagocytic uptake of inorganic colloids by these cells. Neutrophil and monocyte uptake of technetium 99m stannous colloid ( 99m Tc SnC) in whole blood was measured in 10 patients with gram-negative infection (Burkholderia pseudomallei) and 7 controls. Mean uptake per individual neutrophil was reduced in infection. Uptake per monocyte was not significantly different. Blood from six normal individuals was incubated with lysed B. pseudomallei and colloid, which showed reduced neutrophil uptake, but increased monocyte uptake. These results indicate that uptake of 99m Tc SnC stannous colloid can be used to measure alteration in phagocytic cell function. They suggest that infection with B. pseudomallei is associated with reduced phagocytosis by individual neutrophils, possibly through toxic effects of bacterial products. This could have immunopathogenic consequences for this gram-negative infection and may explain why it responds to granulocyte colony-stimulating factor

  3. Sup (99m) Tc-MDP accumulation and absence of concentration of sup (99m) Tc-sulfur colloid in the spleen

    International Nuclear Information System (INIS)

    Calegaro, J.U.M.; Carvalho, A.C.M. de; Ulyssea, R.

    1984-01-01

    A case of a nine years old girl with sickle cell anemia, that showed splenic accumulation of sup (99m) Tc-MDP during bone scintigraphy is reported. On the other side, the scan with sup (99m) Tc-sulfur colloid showed no uptake in the spleen. These findings are discussed with a brief review of the pertinent literature. (Author) [pt

  4. Some problems concerning /sup 99m/Tc-sulfur colloid stability in vivo

    International Nuclear Information System (INIS)

    Komarek, P.; Sup, I.; Krivsky, Z.

    1986-01-01

    On repeated examination of 60 patients with suspected transplanted kidney rejection using /sup 99m/Tc-sulfur colloid administration the urinary bladder appears on the scintigram in ten cases though no free pertechnetate-/sup 99m/Tc had been chromatographically determined before the administration. Therefore other causes of urine bladder visualization were considered. The fate of the radiocolloid in the body after its administration was studied by measuring the radioactivity of blood and plasma or by chromatographic analysis. A sixfold increase in /sup 99m/Tc activity in comparison with that determined chromatographically in the form of free pertechnetate-/sup 99m/Tc was found in the patients blood 45 min after administration. In normal animal experiments, /sup 99m/Tc was found in the rat blood and urine in the form of pertechnetate. (author)

  5. A modified Tc-99m-phytate colloid for liver-spleen imaging

    International Nuclear Information System (INIS)

    Davis, M.A.; Kaplan, M.L.; Ahnberg, D.S.; Cole, C.N.

    1977-01-01

    The results of a comparison of the in vivo biologic properties of sup(99m)Tc-stannous phytate and sup(99m)Tc-stannous phytate precipitated in vitro by the addition of calcium ion, undertaken because of an interest in increasing the splenic uptake of sup(99m)Tc-phytate to a level similar to that obtained with sup(99m)Tc-sulfur colloid, are reported. It was found that: (1) The similarity in the organ distribution values of sup(99m)Tc-phytate and sup(99m)Tc-sulfur colloid is species related (rodents) and decreased splenic uptake of the phytate colloid is found in other primates and man. (2) The gamma scintillation camera with computer region of interest capability is an extremely useful technique for studying the biodistribution and pharmacokinetics of radiodiagnostic agents in primates, where the cost of the animals prohibits the use of the sequential sacrifice technique. (3) The addition of calcium ion to the sup(99m)Tc-phytate complex produces an in vitro colloid with a particle size and biologic distribution very similar to that obtained with sup(99m)Tc-sulfur colloid. (U.K.)

  6. Sentinel lymph node accumulation of Lymphoseek and Tc-99m-sulfur colloid using a '2-day' protocol

    International Nuclear Information System (INIS)

    Wallace, Anne M.; Hoh, Carl K.; Limmer, Karl K.; Darrah, Denise D.; Schulteis, Gery; Vera, David R.

    2009-01-01

    Lymphoseek is a receptor-binding radiopharmaceutical specifically designed for sentinel lymph node (SLN) mapping. We conducted a clinical trial which measured the injection site clearance and sentinel lymph node accumulation after a single intradermal injection of Lymphoseek or unfiltered [ 99m Tc]sulfur colloid (TcSC) using a '2-day' protocol for SLN mapping of breast cancer. Eleven patients with breast cancer participated in this study. Five patients received an intradermal administration of 1.0 nmol of 99m Tc-labeled Lymphoseek; SLN mapping was performed on four subjects within 19 to 27 h. Six subjects received an intradermal administration of TcSC; SLN mapping was performed on five subjects within 18 to 26 h. Lymphoseek exhibited a significantly (P 99m Tc]sulfur colloid and persistent SLN accumulation for at least 24 h.

  7. Gentc99m, computational system for the technetium-99m generator

    International Nuclear Information System (INIS)

    Suparman, I.

    1997-01-01

    The technetium-99m generator is one of the main products of the PPR, as the continuity of the technetium-99m generator production is important for supporting the development of nuclear medicine. GENTC99M has been made for computational for the technetium-99m generator and includes data processing, documentation and information GENTC99M is also very useful in quality control application especially for the determinations of yield and radionuclidic impurities which consume much time. microsoft visual basic for MS-DOS and visual basic for windows have been used for making GENTC99M. Microsoft visual basic has several features that make it an ideal development language for both MS-DOS and Microsoft Windows. These features not only increase productivity, they also provide all the tools and hooks needed to develop some very sophisticated applications. for a production centre like PPR, GENTC99M is very useful to support the data processing, documentation and information system of the technetium-99m generator and it can also be modified for other products

  8. Method of producing radioactive technetium-99M

    International Nuclear Information System (INIS)

    Karageozian, H.L.

    1979-01-01

    A chromatographic process of producing high purity and high yield radioactive Technetium-99m. A solution containing Molybdenum-99m and Technetium-99m is placed on a chromatographic column and eluted with a neutral solvent system comprising an organic solvent and from about 0.1 to less than about 10% of water or from about 1 to less than about 70% of a solvent selected from the group consisting of aliphatic alcohols having 1 to 6 carbon atoms. The eluted solvent system containing the Technetium-99m is then removed leaving the Technetium-99m as a dry, particulate residue

  9. Technetium-99m labeled radiodiagnostic agents for liver and bone marrow scanning and method of preparation

    International Nuclear Information System (INIS)

    Molinski, V.J.; Peacock, F.R.

    1977-01-01

    An improved technetium-99m labeled colloid and method of preparation comprising reducing technetium-99m with stannous oxalate and stabilizing with sodium phytate are described. This radiodiagnostic agent is useful in the scintigraphic examination of the reticuloendothelial system, particularly the liver. In addition, by autoclaving this product with saline, it becomes a superior bone marrow scanning agent

  10. Localization of gastrointestinal bleeding: superiority of 99mTc sulfur colloid compared with angiography

    International Nuclear Information System (INIS)

    Alavi, A.; Ring, E.J.

    1981-01-01

    Preliminary experience with technetium-99m sulfur colloid scintigraphy in 43 patients with lower gastrointestinal bleeding is described. Within minutes of the intravenous introduction of the radiopharmaceutical, a fraction of the injected activity extravasates at the bleeding site and is eliminated from the circulation. Because of rapid clearance of the radiopharmaceutical from the vascular pool by the reticuloendothelial system, a contrast develops between the site of bleeding and surrounding background. Based on animal experiments, bleeding rates as low as 0.05-0.1 ml/min can be detected with this technique. The sensitivity of this technique in the detection of the site of hemorrhage is significantly higher than arteriography or other techniques that use radioactive blood pool indicators. In this study all patients underwent both scintigraphy and arteriography within several hours. In 20 patients with negative scintigrams, arteriography showed no evidence of bleeding. In the other 23 patients with scintigraphic evidence of hemorrhage, arteriograms were positive for bleeding only in 10. In 19 of the 23 patients, a cause for bleeding was eventually established by other means. This technique appears to offer a simple, practical, and reliable approach to the evaluation of patients with lower gastrointestinal bleeding

  11. Evaluation of sup(99m)Tc-Sn-colloid on liver scintigram

    Energy Technology Data Exchange (ETDEWEB)

    Matsuyuki, Y; Kanao, K; Honda, M; Ishihara, S [Sumitomo Hospital, Osaka (Japan)

    1975-04-01

    sup(99m)Tc-Sn-colloid injectable solution and Sn-colloid preparation set were used for nuclear medical examination of the liver and their efficiency was discussed. Both sup(99m)Tc-Sn-colloid injectable solution and Sn-colloid preparation set showed the same kinetics in vivo, and the sup(99m)Tc-Sn-colloid rapidly disappeared from the serum and concentrated to the liver and spleen. Comparing /sup 198/Au-colloid, sup(99m)Tc-Sn-colloid could be increased the administration dose, and provided easy examination within short time period, easy observation from multiple directions, and improvement of resolution by scinticamera. Imaging of the spleen with sup(99m)Tc-Sn-colloid was slightly superior to that with sup(99m)Tc-sulfur-colloid. sup(99m)Tc-Sn-colloid injectable solution which required no procedure of labeling was evaluated as the most safe and easy technique. Side effects were not recognized. As the results, already made preparation, such as sup(99m)Tc-Sn-colloid injectable solution, which provided easy preparation with less absorbed dose of the tissue and high resolution would be frequently required.

  12. Evaluation of sup(99m)Tc-Sn-colloid on liver scintigram

    International Nuclear Information System (INIS)

    Matsuyuki, Yoshihiko; Kanao, Keisuke; Honda, Minoru; Ishihara, Shizumori

    1975-01-01

    sup(99m)Tc-Sn-colloid injectable solution and Sn-colloid preparation set were used for nuclear medical examination of the liver and their efficiency was discussed. Both sup(99m)Tc-Sn-colloid injectable solution and Sn-colloid preparation set showed the same kinetics in vivo, and the sup(99m)Tc-Sn-colloid rapidly disappeared from the serum and concentrated to the liver and spleen. Comparing 198 Au-colloid, sup(99m)Tc-Sn-colloid could be increased the administration dose, and provided easy examination within short time period, easy observation from multiple directions, and improvement of resolution by scinticamera. Imaging of the spleen with sup(99m)Tc-Sn-colloid was slightly superior to that with sup(99m)Tc-sulfur-colloid. sup(99m)Tc-Sn-colloid injectable solution which required no procedure of labeling was evaluated as the most safe and easy technique. Side effects were not recognized. As the results, already made preparation, such as sup(99m)Tc-Sn-colloid injectable solution, which provided easy preparation with less absorbed dose of the tissue and high resolution would be frequently required. (Mukohata, S.)

  13. Lung uptake of /sup 99m/Tc--sulfur colloid in falciparum malaria: case report

    International Nuclear Information System (INIS)

    Ziessman, H.A.

    1976-01-01

    Increased lung uptake of /sup 99m/Tc-sulfur colloid was seen during liver scanning in a patient with falciparum malaria. This finding was due to the enhanced activity of the phagocytic cells of the reticuloendothelial system in the liver, spleen, and lung found in human and experimental malaria. Similar findings in other clinical situations and the relevant literature are reviewed

  14. An investigation of the effect of the quantity of stannous ion on the quality of technetium-99m labelled albumin

    International Nuclear Information System (INIS)

    Billinghurst, M.W.; Rempel, S.; Westendorf, B.A.

    1981-01-01

    The importance of maintaining a low ratio of stannous ion to albumin molecules in order to obtain a high quality technetium-99m labelled albumin is demonstrated. It is further shown that the direct preparation of technetium-99m albumin by reduction of the technetium-99m pertechnetate with stannous ion inevitably leads to the contamination of the product with a certain amount of tin colloid which is also labelled with technetium-99m. It is demonstrated that this can be avoided by utilizing labelling techniques involving the initial formation of other technetium chelates which are less stable than the albumin complex under certain conditions, adding the albumin to that preparation, adjusting the conditions and thus allowing the albumin to become labelled with technetium-99m via an exchange with the original chelating agent. (author)

  15. The performance of gel technetium-99m generator

    International Nuclear Information System (INIS)

    Liu Yishu

    2004-01-01

    Technetium-99m, as one of the important radionuclides in nuclear medical science, has been widely used for diseases diagnosis in both developed and developing countries for many years. Technetium-99m can be obtained from both fission-type and gel-type Tc-99m generator. Fission-type generator was prepared by Molybdenum-99 separated from fission products of uranium-235 and gel-type was prepared by irradiating nature MoO 3 in reactor, and a series of chemical and physical processes. This paper briefly describes the manufacturing technical process of gel-type Technetium-99 generator, including the preparation of target containing nature MoO 3 , the target irradiation in reactor, gel preparation, gel filtration and drying, dried gel cracking, generator loading and activity calibration of generator. The performances of gel-type Technetium-99m generator, such as elution efficiency, elution profile, the pH, Mo breakthrough, Zirconium content, radiochemical purity, radionuclidic purity, sterility and pyrogencity of eluate, are also expatiated in detail. Comparing with fission-type Technetium-99m generator, the defects of gel-type Technetium-99m generator are enumerated and their overcoming solutions are recommended in this paper. (author)

  16. Process for producing radioactive technetium 99 m

    International Nuclear Information System (INIS)

    Karageozian, H.L.

    1979-01-01

    Active aluminium oxide containing Molybdenum 99 and technetium 99 m is treated with a neutral solvent consisting of water, methylethylketone and ethanol. Technetium 99 m remains on the chromatographic material after drying, in the form of a dry powder. Other aliphatic alcohols can also be utilised. (DG) [de

  17. Technetium-99 m generator safety simulation

    International Nuclear Information System (INIS)

    Kang, Sang Koo; Kim, Chong Yeal

    2008-01-01

    Technetium ( 99m Tc) is one of the most widely used radioactive isotopes for diagnosis in the world. In general, 99m Tc is produced inside the so called technetium generator where 99Mo decays to 99m Tc. And the generator is usually made out of lead to shield relatively high energy radiation from 99m Tc and 99 Mo. In this paper, a GEANT4 simulation is carried out to test the safety of the 99m Tc generators, taking domestic and Japanese products with radioactivity of 18.50 GBq (500 mCi) for example. According to the domestic regulation on radiation safety, the dose at 10 cm and 100 cm away from the surface of radiation shielder should not exceed 2 mSv∙h -1 and 0.02 mSv∙h -1 , respectively. The simulated dose turned out about only 10% of the limit, satisfying the domestic regulation

  18. Gastrointestinal bleeding: an accessory spleen causing a false-positive Tc-99m-sulfur colloid study

    International Nuclear Information System (INIS)

    Heyman, S.; Sunaryo, F.P.; Ziegler, M.M.

    1982-01-01

    A Tc-99m-sulfur colloid abdominal scan was performed on a 12-year-old girl to localize the site of gastrointestinal bleeding. The study was normal. When bleeding recurred two weeks later, a repeat study revealed a focal abnormality in the upper abdomen. This was thought to be compatible with a small bleed. However, at surgery an accessory spleen was found, accounting for the abnormal scan

  19. Post-traumatic avascular necrosis of the femoral head predicted by preoperative technetium-99m antimony-colloid scan: an experimental and clinical study

    International Nuclear Information System (INIS)

    Turner, J.H.

    1983-01-01

    Technetium-99m antimony colloid was used to visualize the bone marrow of the head of the femur within twenty-four hours after interruption of the blood supply by subcapital osteotomy and section of the ligamentum teres in thirteen rabbits and within twenty-four hours after a subcapital fracture in thirty patients. Of the rabbits, all showed loss of marrow radioactivity over the affected femoral head. Bone-imaging with technetium-99m methylene diphosphonate, in contrast, failed to demonstrate any abnormality in the avascular head of the femur for as long as forty-eight hours after osteotomy. This difference between the marrow scan and the bone scan was attributed to earlier loss of function in the marrow cells than in the osteocytes. The thirty patients who had a preoperative scan within twenty-four hours after sustaining a subcapital fracture were treated by internal fixation with a Richards screw and plate and were followed for as long as two years, or until the patient died or radiographs showed evidence of avascular necrosis. The preoperative technetium-99m antimony-colloid activity in the head of the fractured femur was normal in sixteen patients and absent in fourteen; two of the fourteen had no activity in either hip, which precluded assessment of the fractured hip in these patients. In fifteen of the sixteen hips, preservation of the uptake in the marrow of the head of the fractured femur preoperatively predicted normal healing. Late segmental collapse developed in the remaining hip. In eleven of the twelve patients who had loss of marrow activity in the femoral head preoperatively, avascular necrosis developed within two years

  20. The radiopharmaceuticals labelled with technetium-99m and the radiopharmacy; Les radiopharmaceutiques marques au technetium-99m et la radiopharmacie

    Energy Technology Data Exchange (ETDEWEB)

    Bodenant, V

    1998-10-01

    In less than fifty years, the place of nuclear medicine is become primordial. Among all the radiopharmaceuticals used in nuclear medicine, the technetium-99m is the most used because of its physico-chemical properties and its great availability with the molybdenum-99m - technetium-99m generator. Since 1992, the radiopharmaceuticals, the packages, the generators are included in the pharmaceutic monopole. They are now under the reliability of the radio-pharmacist. This thesis has for object to introduce these different radiopharmaceuticals labelled with technetium-99m and to show the primordial place of the radio-pharmacist in a service of nuclear medicine. (N.C.)

  1. Intrathoracic extramedullary hematopoiesis: appearance on /sup 99m/Tc sulfur colloid marrow scan

    International Nuclear Information System (INIS)

    Bronn, L.J.; Paquelet, J.R.; Tetalman, M.R.

    1980-01-01

    Imaging of the bone marrow by radionuclide scanning was performed using colloids, which are phagocytized by the reticuloendothelial cells of the marrow, or radioiron, which is incorporated into reticulocytes. The use of the former radiopharmaceutical is based on the assumption, generally valid except in aplastic states or after irradiation, that the distribution of hematopoietic and reticuloendothelial tissue in the marrow is similar. Regardless of the method used, active adult marrow is normally distributed only in the axial skeleton and proximal humeri and femurs. Marrow imaging has been used in the evaluation of myeloproliferative disorders, leukemia, lymphoma, aplastic states, malignancy metastatic to marrow, and hemolytic anemia. We report a case of thalassemia major in which the diagnosis of intrathoracic extramedullary hematopoiesis was confirmed with the /sup 99m/Tc sulfur colloid bone marrow scan

  2. Experimental esophagitis: evaluation by radionuclide esophagogram (sup(99m)TC-sulfur colloid). Manometric and histopathologic correlations

    International Nuclear Information System (INIS)

    Taillefer, R.; Beauchamp, G.; Devito, M.P.; Lamoureux, C.; Levasseur, A.

    1983-01-01

    The radionuclide esophageal transit time (using sup(99m)Tc-sulfur colloid) is abnormal in peptic esophagitis. The mechanisms responsible for such results are not fully understood. The hypothesis are multiple. In order to evaluate the effects of acute inflammation of esophageal wall on the radionuclide esophagogram (RE), 12 cats were submitted to manometry, endoscopy and RE before and after esophageal infusion of chlorhydric acid (HCl 0.1 N). Manometry results demonstrated a marked decline of the esophageal contraction waves pressure and lower esophageal sphincter (LES) pressure. There was also an increased esophageal contraction duration and duration of LES relaxation. The radionuclide esophageal transit time was markedly increased. The radiocolloid retention was secondary to adherence of it to the sites of inflamed and ulcerated esophageal wall. The radionuclide adhesion corresponded to the degree of esophagitis. These results confirm that peptic esophagitis can cause esophageal motor dysfunction which can be identified by a sup(99m)Tc-sulfur colloid esophagogram. The retention of radiocolloid corresponded to the sites inflamed esophageal wall. Thus, the radionuclide retention and transit time, when abnormal, are an index of esophageal disorders [fr

  3. Experimental esophagitis: evaluation by radionuclide esophagogram (sup(99m)TC-sulfur colloid). Manometric and histopathologic correlations

    Energy Technology Data Exchange (ETDEWEB)

    Taillefer, R.; Beauchamp, G.; Devito, M.P.; Lamoureux, C.; Levasseur, A. (Hopital Maisonneuve-Rosemont, Universite de Montreal (Canada))

    1983-01-01

    The radionuclide esophageal transit time (using sup(99m)Tc-sulfur colloid) is abnormal in peptic esophagitis. The mechanisms responsible for such results are not fully understood. The hypothesis are multiple. In order to evaluate the effects of acute inflammation of esophageal wall on the radionuclide esophagogram (RE), 12 cats were submitted to manometry, endoscopy and RE before and after esophageal infusion of chlorhydric acid (HCl 0.1 N). Manometry results demonstrated a marked decline of the esophageal contraction waves pressure and lower esophageal sphincter (LES) pressure. There was also an increased esophageal contraction duration and duration of LES relaxation. The radionuclide esophageal transit time was markedly increased. The radiocolloid retention was secondary to adherence of it to the sites of inflamed and ulcerated esophageal wall. The radionuclide adhesion corresponded to the degree of esophagitis. These results confirm that peptic esophagitis can cause esophageal motor dysfunction which can be identified by a sup(99m)Tc-sulfur colloid esophagogram. The retention of radiocolloid corresponded to the sites of inflamed esophageal wall. Thus, the radionuclide retention and transit time, when abnormal, are an index of esophageal disorders.

  4. Effect of (OPC) oligomeric pronthocyanidine extracted of grape seed on chromosomal aberrations for Tc 99m sulfur colloid in laboratory animal

    International Nuclear Information System (INIS)

    Alwan, I. F.; Ahmed, A.M.; Mohamad, H. A.

    2012-12-01

    The aims study to assess the protective material (OPC) oligomeric pronthocyanidine grape seed extract, to decrease the effect of Technetium 99 m radiation used in on the (Chromosomal Aberration) in the genes for bone marrow in laboratory animals. Been diagnosed by a composite (OPC) optical spectrometer (UV.vis) to determine the wavelength of the compound, for the purpose of examination and analysis by a high-purity HPLC to determine the components of grape seed extract. Has been handing laboratory animals, grape seed extract material (OPC) at a dose (150 mg/kg) for two weeks and then were injected to the solution of sulfur colloidal label with Tc 99 m doses of radiation to the following quantity (400 u ci, 250 u ci, 150 u ci / 0.1 m1). The treated animals by extract (OPC) showed decrease in the proportion of chromosomal changes resulting from the impact of injection differences dose compared to animals injected to the same radiation dose and non treated animal with (OPC). The result indicated there are significant differences (p>0.05) at the level of changes in chromosomal in genes of animals untreated compared with the group of animals treated with (OPC) and injected with the same radiation dose compared a control animal group. (Author)

  5. Study on sup(99m)Tc-colloid accumulation of in vitro clots and thrombi in rats

    Energy Technology Data Exchange (ETDEWEB)

    Ohguchi, Manabu [Kanazawa Univ. (Japan). School of Medicine

    1983-02-01

    The accumulation of different sup(99m)Tc-colloids in vitro clot, venous thrombi and intravascular fibrin deposits in rats was studied. Blood clot was produced by incubating fresh blood at room temperature for three hours. The mean value of % uptake of sup(99m)Tc-Sn colloid in clot was 96.2 % and higher than that of any other sup(99m)Tc-colloids. Venous thrombi in rats were made by clamping the left femoral vein segments for 5 minutes. With sup(99m)Tc-Sn colloid, the mean value of the ratio of the radioactivity in the clamped vein segment to the control segment (L/R ratio) was 54.5. L/R ratios of others were 24.2 with sup(99m)Tc-phytate, 12.1 with sup(99m)Tc-sulfur colloid, 3.9 with sup(99m)Tc-rhenium colloid, 2.4 with sup(99m)Tc-millimicrosphere albumin. L/R ratios were higher for the fresh thrombi, significant uptake was also observed up to seven days. Intravascular fibrin deposits were induced by i.p. injection of endotoxin into rats. Three hours after injection of endotoxin, sup(99m)Tc-colloids were i.v. injected. Significant lung uptake was observed in sup(99m)Tc-colloids except in sup(99m)Tc-rhenium colloid. And the most remarkable change of lung uptake was observed in sup(99m)Tc-Sn colloid. Significant kidney uptake was observed in sup(99m)Tc-Sn colloid and sup(99m)Tc-sulfur colloid. And the most remarkable change of kidney uptake was also observed in sup(99m)Tc-Sn colloid. When heparin was injected i.v. at the same time as endotoxin injection, lung uptake of sup(99m)Tc-Sn colloid was significantly decreased. However, the heparin effect on kidney uptake of sup(99m)Tc-Sn colloid was more significant than on lung uptake. The results in this study indicated that sup(99m)Tc-Sn colloid showed the greatest affinity to in vitro clots, venous thrombi and intravascular fibrin deposits.

  6. Radiation decomposition of technetium-99m radiopharmaceuticals

    International Nuclear Information System (INIS)

    Billinghurst, M.W.; Rempel, S.; Westendorf, B.A.

    1979-01-01

    Technetium-99m radiopharmaceuticals are shown to be subject to autoradiation-induced decomposition, which results in increasing abundance of pertechnetate in the preparation. This autodecomposition is catalyzed by the presence of oxygen, although the removal of oxygen does not prevent its occurrence. The initial appearance of pertechnetate in the radiopharmaceutical is shown to be a function of the amount of radioactivity, the quantity of stannous ion used, and the ratio of /sup 99m/Tc to total technetium in the preparation

  7. Adsorption of technetium-99m tetrofosmin and technetium-99m furifosmin on plastic syringes

    International Nuclear Information System (INIS)

    Bartosch, R.; Granegger, S.; Sinzinger, H.

    1998-01-01

    Some groups have reported that adsorption of radiopharmaceuticals on disposable plastic syringes can reach levels of almost 50%. This high loss of radioactivity stimulated us to carry out similar studies. Our measurements were done in combination with patient studies. Therefore, we used 2-ml syringes, all of the same brand. The radioactivity in the syringe was measured immediately before and after injection. a total of 500-600 MBq technetium-99m labelled tetrofosmin or technetium-99m furifosmin was administered to 48 patients using four different injection techniques (n = 6 for each technique with each tracer): with needles, 1 min blood incubation at 22 C, 10 or 30 min after preparation of the tracer; with butterflies, 1 min blood incubation at 22 C, 10 or 30 min after preparation of the tracer. Neither in syringes nor in needles or butterflies did more than 7% of the initial radioactivity remain. The entire residual activity in syringe plus needle or syringe plus butterfly together never exceeded the 9% limit. Furthermore, in a pilot study we measured the remaining radioactivity in the vial; here, too, we found no more than 14% of total radioactivity. These findings indicate that total retention of radioactivity during elution and application of 99m Tc-tetrofosmin and 99m Tc-furifosmin with material used in our setting does not approach relevant amounts. (orig.)

  8. Sentinel lymph node accumulation of Lymphoseek and Tc-99m-sulfur colloid using a '2-day' protocol

    Energy Technology Data Exchange (ETDEWEB)

    Wallace, Anne M. [Department of Surgery, University of California, San Diego, CA 92103 (United States); Moores UCSD Cancer Center, University of California, La Jolla, CA 92093 (United States); Hoh, Carl K. [Moores UCSD Cancer Center, University of California, La Jolla, CA 92093 (United States); Division of Nuclear Medicine, University of California, San Diego, CA 92103 (United States); UCSD Molecular Imaging Program, University of California, La Jolla, CA 92093 (United States); Limmer, Karl K. [Department of Surgery, University of California, San Diego, CA 92103 (United States); Darrah, Denise D. [Moores UCSD Cancer Center, University of California, La Jolla, CA 92093 (United States); Schulteis, Gery [Department of Anesthesiology, University of California, San Diego, CA 92103 (United States); Vera, David R. [Moores UCSD Cancer Center, University of California, La Jolla, CA 92093 (United States); Division of Nuclear Medicine, University of California, San Diego, CA 92103 (United States); UCSD Molecular Imaging Program, University of California, La Jolla, CA 92093 (United States)], E-mail: dvera@ucsd.edu

    2009-08-15

    Lymphoseek is a receptor-binding radiopharmaceutical specifically designed for sentinel lymph node (SLN) mapping. We conducted a clinical trial which measured the injection site clearance and sentinel lymph node accumulation after a single intradermal injection of Lymphoseek or unfiltered [{sup 99m}Tc]sulfur colloid (TcSC) using a '2-day' protocol for SLN mapping of breast cancer. Eleven patients with breast cancer participated in this study. Five patients received an intradermal administration of 1.0 nmol of {sup 99m}Tc-labeled Lymphoseek; SLN mapping was performed on four subjects within 19 to 27 h. Six subjects received an intradermal administration of TcSC; SLN mapping was performed on five subjects within 18 to 26 h. Lymphoseek exhibited a significantly (P<.001) faster injection site clearance than TcSC. The mean Lymphoseek clearance half-time was 2.18{+-}1.09 h compared to 57.4{+-}92.8 h for TcSC. The mean sentinel lymph node uptake of Lymphoseek (1.5{+-}1.7%) and TcSC (3.5{+-}3.1%) was statistically equivalent (P=.213). When an intradermal injection is employed, Lymphoseek demonstrated faster injection site clearance than unfiltered [{sup 99m}Tc]sulfur colloid and persistent SLN accumulation for at least 24 h.

  9. Technetium-99m labeled radiodiagnostic agents and method of preparation

    International Nuclear Information System (INIS)

    Molinski, V.J.; Wilczewski, J.A.

    1977-01-01

    A method of preparing improved technetium-99m labeled radiodiagnostic agents by reducing technetium-99m with stannous tartrate is described. Such radiodiagnostic agents are useful in scintigraphic examinations of the bone and lung

  10. Adsorption of technetium-99m tetrofosmin and technetium-99m furifosmin on plastic syringes

    Energy Technology Data Exchange (ETDEWEB)

    Bartosch, R.; Granegger, S.; Sinzinger, H. [Department of Nuclear Medicine, University of Vienna (Austria)

    1998-09-01

    Some groups have reported that adsorption of radiopharmaceuticals on disposable plastic syringes can reach levels of almost 50%. This high loss of radioactivity stimulated us to carry out similar studies. Our measurements were done in combination with patient studies. Therefore, we used 2-ml syringes, all of the same brand. The radioactivity in the syringe was measured immediately before and after injection. a total of 500-600 MBq technetium-99m labelled tetrofosmin or technetium-99m furifosmin was administered to 48 patients using four different injection techniques (n = 6 for each technique with each tracer): with needles, 1 min blood incubation at 22 C, 10 or 30 min after preparation of the tracer; with butterflies, 1 min blood incubation at 22 C, 10 or 30 min after preparation of the tracer. Neither in syringes nor in needles or butterflies did more than 7% of the initial radioactivity remain. The entire residual activity in syringe plus needle or syringe plus butterfly together never exceeded the 9% limit. Furthermore, in a pilot study we measured the remaining radioactivity in the vial; here, too, we found no more than 14% of total radioactivity. These findings indicate that total retention of radioactivity during elution and application of {sup 99m}Tc-tetrofosmin and {sup 99m}Tc-furifosmin with material used in our setting does not approach relevant amounts. (orig.) With 4 figs., 1 tab., 7 refs.

  11. The radiopharmaceuticals labelled with technetium-99m and the radiopharmacy

    International Nuclear Information System (INIS)

    Bodenant, V.

    1998-01-01

    In less than fifty years, the place of nuclear medicine is become primordial. Among all the radiopharmaceuticals used in nuclear medicine, the technetium-99m is the most used because of its physico-chemical properties and its great availability with the molybdenum-99m - technetium-99m generator. Since 1992, the radiopharmaceuticals, the packages, the generators are included in the pharmaceutic monopole. They are now under the reliability of the radio-pharmacist. This thesis has for object to introduce these different radiopharmaceuticals labelled with technetium-99m and to show the primordial place of the radio-pharmacist in a service of nuclear medicine. (N.C.)

  12. Technetium-99m-human fibrinogen

    International Nuclear Information System (INIS)

    Wong, D.W.; Mishkin, F.S.

    1975-01-01

    Exogenous fibrinogen has been successfully labeled with /sup 99m/Tc using a modified electrolytic method. The exact labeling mechanism has not been determined. Experimental data suggest that the labeling process of /99m/Tc-fibrinogen is quite similar to that of /sup 99m/Tc-human serum albumin as reported earlier by Benjamin. Technetium-99m-fibrinogen is stable in human plasma or in 1 percent buffered human serum albumin. A binding efficiency of 76 percent has been achieved with approximately 25 percent clottable protein. The entire labeling procedure requires less than 1 hr of preparation time. This short labeling time in a closed system may allow development of a practical method for labeling autologous fibrinogen, thus eliminating the risk of hepatitis transmission. (U.S.)

  13. Preclinical evaluation of technetium 99m-labeled P1827DS for infection imaging and comparison with technetium 99m IL-8.

    NARCIS (Netherlands)

    Krause, S.; Rennen, H.J.J.M.; Boerman, O.C.; Baumann, S.; Cyr, J.E.; Manchanda, R.; Lister-James, J.; Corstens, F.H.M.; Dinkelborg, L.M.

    2007-01-01

    BACKGROUND: The technetium 99 m (99mTc)-radiolabeled, leukocyte-avid peptide-glycoseaminoglycan complex, [99mTc]P1827DS, has been synthesized as an improved infection/inflammation imaging agent to [99mTc]P483H (LeukoTect, Diatide). In a phase I/II clinical trail, [99mTc]P483H images were equivalent

  14. Evaluation of liver function in carbon tetrachloride-damaged rabbits by dynamic SPECT. Comparison of 99mTc-GSA and 99mTc-Sn colloid

    International Nuclear Information System (INIS)

    Kiuchi, Takaaki; Kawasaki, Yukiko; Hino, Ichirou; Kojima, Kanji; Ohkawa, Motoomi; Tanabe, Masatada; Tamai, Toyosato.

    1994-01-01

    Technetium-99m-DTPA-galactosyl human serum albumin ( 99m Tc-GSA) is a new ligand that binds specifically to asialoglycoprotein receptors in hepatocytes. We performed liver dynamic SPECT using 99m Tc-GSA and 99m Tc-Sn colloid in nine normal control rabbits and 17 chronically CCl 4 -damaged rabbits (total 29 examinations), and also performed liver function tests (ICGR 15 , Alb, etc). Using the obtained dynamic SPECT data, we analyzed the liver kinetics of 99m Tc-Sn colloid using a one-compartment model (hepatic blood flow [K]) and 99m Tc-GSA using a two-compartment model (hepatic blood flow and receptor binding [K 1 ], catabolism [K 2 ]). As the CCl 4 -treated period increased, K 1 decreased most significantly. K 1 showed the most statistically significant correlation with the results of liver function tests, ICGR 15 (p 1 showed a correlation with the hepatic fibrosis of the HAI score. From the present results, liver dynamic SPECT using 99m Tc-GSA may be said to provide a novel method for the evaluation of hepatic functional reserve. (author)

  15. Preparation of a generator of technetium-99m

    International Nuclear Information System (INIS)

    Jimeno de Osso, F.

    1981-01-01

    Practical description is given of equipment and operations necessary in the preparation of an isotopic generator of technetium-99m. The preparation and application of the active solution and throughly washed of the chromatographic column have been studied in order to allow molibdenum-99 to be adsorbed on a small band, and the solution of tectium-99m to be eluted with high efficiency and purity. The equipment and accesories used are easy and safety to manage, simplifying operations to be carried out with the active product, eliminating the sterile environment in the shielded cell, and facilitating the preparation of the solution of technetium-99m in sterile and pyrogen-free conditions.(author) [es

  16. Massive splenomegaly with multiple defects in a chronic myelogenous leukemia demonstrated by sup(99m)Tc-sulfur colloid scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Shih, W J; DeLand, F H; Domstad, P A

    1983-11-14

    A sup(99m)Tc-sulfur colloid liver-spleen scintigram of a 78-year-old woman with a painful, large mass in the left upper quadrant of the abdomen revealed massive splenomegaly with multiple areas of absent radioactivity. Splenectomy was performed and the removed spleen, weighing 2,010 g, was confirmed to contain acute and old infarcts with leukemic cell and megakaryocyte infiltration.

  17. Ligand-free, protein-bound technetium-99m iron-dextran enhancement of technetium pyrophosphate uptake in tumours

    International Nuclear Information System (INIS)

    Pojer, P.M.; Jakovljevic, A.C.; Wise, K.N.

    1985-01-01

    The biodistribution of technetium-99m was studied in T-cell lymphoma and selected organs of iron-dextran treated and control mice given technetium-99m pyrophosphate. The results showed that high serum iron levels increased tumour uptake of technetium pyrophosphate. This supports the hypothesis that technetium, in common with other metal-based tumour seeking radiopharmaceuticals, is transported to tumours as a ligand-free protein-bound cation. (U.K.)

  18. Fever of unknown origin and the value of gallium-67 and technetium-99/sup m/ for defining abnormality of the spleen: a case report

    International Nuclear Information System (INIS)

    Coopersmith, A.; Ritchey, A.K.; Zinkham, W.H.

    1975-01-01

    A three-year-old white female with acute promyelocytic leukemia developed persistent fever after successful induction-remission therapy; many large monilial abscesses were later found in the grossly enlarged spleen. Although the technetium/sup 99M/-sulfur colloid scan prior to splenectomy suggested only a slight abnormality of the spleen, the gallium-67 citrate scintigraph showed a marked increase in gallium accumulation. The disparate results of the scanning techniques utilized in this patient suggest that it may be necessary to use more than one type of radiopharmaceutical to define an enlarged spleen, as well as the pathological process responsible for its enlargement

  19. Bronchoalveolar lavage and technetium-99m glucoheptonate imaging in chronic eosinophilic pneumonia

    International Nuclear Information System (INIS)

    Lieske, T.R.; Sunderrajan, E.V.; Passamonte, P.M.

    1984-01-01

    A patient with chronic eosinophilic pneumonia was evaluated using bronchoalveolar lavage, technetium-99m glucoheptonate, and transbronchial lung biopsy. Bronchoalveolar lavage revealed 43 percent eosinophils and correlated well with results of transbronchial lung biopsy. Technetium-99m glucoheptonate lung imaging demonstrated intense parenchymal uptake. After eight weeks of corticosteroid therapy, the bronchoalveolar lavage eosinophil population and the technetium-99m glucoheptonate uptake had returned to normal. We suggest that bronchoalveolar lavage, with transbronchial lung biopsy, is a less invasive way than open lung biopsy to diagnose chronic eosinophilic pneumonia. The mechanism of uptake of technetium-99m glucoheptonate in this disorder remains to be defined

  20. Labelling of biological structures with technetium 99 m

    International Nuclear Information System (INIS)

    Bernardo Filho, M.

    1988-01-01

    The labelling of red blood cells (RBC) with technetium 99m ( 99m Tc) depends on several factors, as the stannous ion (Sn ++ ) concentration, the time and temperature of incubation, the anticoagulant utilized, the presence of plasma proteins (PP) and others. Although the blinding of 99m Tc with hemoglobin and PP are similar, they appear to have specific characteristics as demonstrated by precipitation with alcohol, acetone, trichloroacetic acid, hydrochloric acid and mercury chloride. The bacterial cultures labeled with Technetium- 99m , at optimal Sn ++ ion concentration, presents a large stability and their viability is not altered by this treatment. The electrophoretic mobility, the hydrophobicity, the cationized ferritin distribution and the adherence to human buccal epithelial cells are not modified either. The possibility of labelling with 99m Tc of planaria and cercariae of Schistossoma mansoni evaluative cycle increases the utilization of this radionuclide to an experimental level. The results described with the labelling of these biological structures with 99m Tc demonstrated that stable labeled and viable operations are obtained. (author)

  1. [99mTc]MAG3-mannosyl-dextran: a receptor-binding radiopharmaceutical for sentinel node detection

    International Nuclear Information System (INIS)

    Vera, David R.; Wallace, Anne M.; Hoh, Carl K.

    2001-01-01

    Technetium-99m-labeled benzoyl-mercaptoacetylglycylglycyl-glycine-mannosyl-dextran ([ 99m Tc]MAG 3 -mannosyl-dextran) is a receptor-binding radiotracer that binds to mannose-binding protein, a receptor expressed by reticuloendothelial tissue. This agent is composed of a 10.5-kilodalton molecule of dextran and multiple units of mannose, and benzoyl-mercaptoacetylglycylglycyl-glycine (BzMAG 3 ). The tetraflorophenol-activated ester of BzMAG 3 and the imidate of thiomannose were used to covalently attach BzMAG 3 and mannose to an amino-terminated conjugate of dextran. This yielded a 19-kilodalton macromolecule consisting of 3 BzMAG 3 and 21 mannose units per dextran. Dynamic light scattering was used to measure a mean diameter of 5.5 nanometers for BzMAG 3 -mannosyl-dextran and 0.28 microns for filtered Tc-99m sulfur colloid. A preliminary sentinel node detection study employing right fore and hind footpad injections of [ 99m Tc]MAG 3 -mannosyl-dextran and left fore and hind footpad injections of filtered Tc-99m sulfur colloid demonstrated greater sentinel lymph node uptake by the receptor-binding agent

  2. Determination of radiochemical purity and pharmacokinetic parameters of sup(99m)Tc-sulphur colloid and sup(99m)Tc-tin colloid

    International Nuclear Information System (INIS)

    Jovanovic, V.; Konstantinovska, D.; Milivojevic, K.; Bzenic, J.

    1981-01-01

    Labelling yield and radiochemical purity, higher than 95%, of sup(99m)Tc-colloid preparations were determined by using the paper chromatography method. Less than 3% of labelled citric acid, added to the preparation as a buffer solution, has been found in sup(99m)Tc-sulphur colloid. High radiochemical purity and optimum size of colloid particles has also been proved by biodistribution studies on experimental animals. The analysis performed has shown that more than 50% of sup(99m)Tc-colloid preparations excreted by urine is sup(99m)TcO - , the remaining past 50% being protein bound sup(99m)Tc. Biological half-time of excretion of the fast phase is the same for both preparations, i.e. 10 min, while for the slow component it is 120 min in sup(99m)Tc-S-colloid and 160 min in sup(99m)Tc-Sn colloid. (orig.) [de

  3. Discussion on twenty-two hepatobiliary scintigraphs performed with technetium 99m-labelled N-(2,6 dimethylphenylcarbamoylmethyl) iminodiacetic acid (or HIDA-99mTc) at the Val-de-Grace Army Instruction Hospital

    International Nuclear Information System (INIS)

    Hoste, Philippe.

    1978-12-01

    Intraveinously injected technetium 99m-labelled N-(2,6 dimethyl-phenylcarbamoylmethyl) iminodiacetic acid, or HIDA-99mTc, is taken up by the hepatocytes and secreted in the bile, a fraction being normally eliminated by the kidneys. Isotopic examination with HIDA-99mTc gives valuable information on the morphology of the liver during the first minutes of the test, thus revealing the presence of parenchyma disease. In all observed cases of secondary hepatic localisations in particular the HIDA-99mTc images overlie those obtained with technetium colloids. By the examination it is also possible: - to establish the existence or otherwise of a functional vesicle, - to follow the path of the radiotracer along the bile duct. In short, HIDA-99mTc hepatobiliary scintigraphy is particularly useful for the study of hepatocyte uptake and bile elimination since it allows a continuous quantitative study of the liver-bile function under given physiological conditions [fr

  4. Under used technetium-99m generators

    International Nuclear Information System (INIS)

    Mushtaq, A.

    2001-01-01

    Health care reform truly has become a global issue and it will undoubtedly have a dramatic impact on the future of nuclear medicine business in particular. A bigger concern within the nuclear medicine community is its competitiveness with other modalities and cost effectiveness.Technetium-99m and its generators are playing key role for the majority of diagnostic scans performed in the world today. Availability of ''9''9''mTc can be increased if it is separated from ''9''9Mo after much shorter growth times. After proper planning with the extra ''9''9''mTc, a significant number of scans can be performed or we would be able to order approximately 30% low activity ''9''9Tc generators to fulfill our requirements

  5. The quality control of technetium-99m radiopharmaceuticals produced at the AAEC Research Establishment

    International Nuclear Information System (INIS)

    Farrington, K.J.

    1983-08-01

    The methods of quality control used for technetium-99m radiopharmaceuticals produced at the AAEC Research Establishment are described for both non-fission and fission derived sources of sodium pertechnetate, technetium-99m labelled radipopharmaceuticals, and reagent kits produced for technetium-99m labelling

  6. Technetium-99m Sestamibi in Multiple Myeloma

    International Nuclear Information System (INIS)

    Saber, R.A.

    2002-01-01

    Technetium-99m 2-methoxy - isobutyl - isonitrile (99mTc-MIBI) has been reported to be useful in evaluating patients with multiple myeloma. The aim of this study is to evaluate the role of technetium-99m sestamibi (99mTc-MIBI) scintigraphy in the diagnosis. staging and follow-up of patients with multiple myeloma. Methods and Materials: twenty-five consecutive patients with multiple myeloma were studied using 99mTc- MIBI. Of the 25 patients included in this study, 6 were in stage I, II in stage II and 8 in stage III. Anterior and posterior whole-body imaging were obtained 20 min after I.V. injection of 740 MBq of 99mTc-MIBI. Four different MIBI patterns could be described in our patients: physiological (P), diffuse (D), focal (F) and combined diffuse and focal (D+F). All patients in stages II and III as well as 3 patients in stage I were treated with chemotherapy (cyclophosphamide and prednisone) then 99mTc-MlBI scans were repeated after 6 courses. Results: in comparison to conventional X-ray skeletal survey, 99mTc-MIBI scans showed a higher number of myeloma bone disease at diagnosis. All patients with stage II and III multiple myeloma were positive with 99mTc-MlBl scans at diagnosis. The pattern of positive MIBI accumulation was diffuse in 13 (52%) patients, focal in 4 (16%) and combined focal and diffuse in 6 (24%) patients. The intensity of 99mTc-MIBI correlated with disease activity as determined by lactate dehydrogenase (LDH), number of plasma cells in bone marrow and serum electrophoresis. There was a direct correlation between 99mTc-MIBI scan result and clinical outcome of patients following 6 courses of chemotherapy. Sensitivity and specificity of 99mTc-MIBI scintigraphy in detecting myeloma bone lesions were 92% and 90% respectively. Conclusion: 99mTc-MIBI scintigraphy is a reliable method to evaluate bone marrow activity in patients with multiple myeloma and follow-up of myeloma bone lesions

  7. Radionuclide Basics: Technetium-99

    Science.gov (United States)

    Technetium-99 (chemical symbol Tc-99) is a silver-gray, radioactive metal. It occurs naturally in very small amounts in the earth's crust, but is primarily man-made. Technetium-99m is a short-lived form of Tc-99 that is used as a medical diagnostic tool.

  8. Total-hip arthroplasty: Periprosthetic indium-111-labeled leukocyte activity and complementary technetium-99m-sulfur colloid imaging in suspected infection

    International Nuclear Information System (INIS)

    Palestro, C.J.; Kim, C.K.; Swyer, A.J.; Capozzi, J.D.; Solomon, R.W.; Goldsmith, S.J.

    1990-01-01

    Indium-111-labeled leukocyte images of 92 cemented total-hip arthroplasties were correlated with final diagnoses. Prostheses were divided into four zones: head (including acetabulum), trochanter, shaft, and tip. The presence (or absence) and intensity of activity in each zone was noted, and compared to the corresponding contralateral zone. Though present in all 23 infected arthroplasties, periprosthetic activity was also present in 77% of uninfected arthroplasties, and was greater than the contralateral zone 51% of the time. When analyzed by zone, head zone activity was the best criterion for infection (87% sensitivity, 94% specificity, 92% accuracy). Fifty of the arthroplasties were studied with combined labeled leukocyte/sulfur colloid imaging. Using incongruence of images as the criterion for infection, the sensitivity, specificity, and accuracy of the study were 100%, 97%, and 98%, respectively. While variable periprosthetic activity makes labeled leukocyte imaging alone unreliable for diagnosing hip arthroplasty infection, the addition of sulfur colloid imaging results in a highly accurate diagnostic procedure

  9. Lymphoscintigraphy in melanoma patients using Tc-99m dextran

    International Nuclear Information System (INIS)

    Marciano, D.; Padgett, H.; Henze, E.; Carlson, C.; Bennett, L.R.

    1984-01-01

    Surgical removal of regional lymph nodes draining the site of a melanoma is a generally practiced procedure. It is often difficult in many cases of truncal melanomas near the midline or near the waistline to determine which group or groups of nodes to remove. Colloidal Au-198, Tc-99m sulfur colloid, and Tc-99m antimony sulfur colloid have all been used and have given useful clinical information. Objections, however, have been raised to the local radiation dose with these compounds. To reduce this problem while obtaining greater information on lymph flow, the authors have studied dextran, a macromolecule commonly used as plasma substitute. Dextran (average mol. wt. 72,000) labeled with Tc-99m has been used to study lymph drainage from the site of truncal melanoma in 29 patients. Serial images in the first hour following intradermal injection clearly demonstrate tracer in efferent lymphatics within 5 to 10 minutes, and brief pooling in the regional lymph nodes between 20 and 60 minutes. When compared with particulate tracers such as micro Tc-99m sulfur colloid, the Tc-99m dextran appears to move much faster through the lymphatics. Overall distribution of the Tc-99m dextran to lymph nodes is very similar to previous findings with micro Tc-99m sulfur colloid. Dextran drainage to more than one group of regional nodes was seen in 12/29 patients as compared with 17/50 patients using micro Tc-99m sulfur colloid. The superior images with Tc-99m dextran appear to make it the agent of choice

  10. Extraosseous uptake of 99sup(m)technetium methylene diphosphonate

    International Nuclear Information System (INIS)

    Sty, J.R.; Kun, L.; Casper, J.; Babbitt, D.P.

    1980-01-01

    A child with a ganglioneuroblastoma and tumor uptake of 99 sup(m)technetium methylene diphosphate ( 99 sup(m)Tc-MDP) is presented. After surgical removal of an encapsulated tumor and radiation therapy, an interval bone scan demonstrated the same presurgical abnormality. Awareness of abnormal uptake of 99 sup(m)Tc-MDP in irradiated renal tissue prevents interpreting radiation nephritis as recurrent tumor. (orig.) [de

  11. Tc-99m sulfur colloid spleen imaging following splenic artery and vein resection for pancreas organ donation

    International Nuclear Information System (INIS)

    Kuni, C.C.; Crass, J.R.; Du Cret, R.P.; Boudreau, R.J.; Loken, M.K.

    1987-01-01

    The authors retrospectively studied the records and Tc-99m sulfur colloid (TSC) splenic artery and vein resection for donation to HLA-compatible relatives. Of 37 patients with postoperative TSC studies, four had no postoperative splenic abnormalities. Nineteen of the abnormal TSC studies were followed with TSC studies 2 weeks to 14 months later; three showed no change, seven showed improvements,and ten became normal. One patient required splenectomy 2 days after pancreatectomy for splenic infarction; her TSC study showed no uptake. These data suggest that the spleen usually survives splenic artery and vein resection. Absent splenic TSC uptake raises the possibility of splenic infarction but usually improves

  12. Evaluation of reflux oesophagitis with technetium-99m-labelled ...

    African Journals Online (AJOL)

    Sucralfate binds with denuded protein to form a stable complex to protect the damaged mucosa. By utilising this property, technetium-99m-labelled sucraJfate can be used to demonstrate ulceration in the upper gastro-intestinal tract. Aim: The aim of this study was to evaluate 99mTc-labelled sucralfate in the diagnosis of ...

  13. Method for radiolabeling proteins with technetium-99m

    International Nuclear Information System (INIS)

    Crockford, D.R.; Rhodes, B.A.

    1984-01-01

    In accordance with this invention, a substrate to be radiolabeled with technetium-99m is admixed with a buffered stannous chloride composition having a pH between about 4.5 and about 8.5 wherein the stannous chloride is produced from a non-oxidized tin source, the buffered stannous chloride is purged of oxygen and the buffer comprises a mixture of alkali metal biphthalate and an alkali metal tartrate. Alternatively, the buffer may include alkali metal borate or gentisate. The stannous chloride solution is admixed with the buffer and the resultant mixture is neutralized with sodium hydroxide. The neutralized solution then is admixed with the substrate eventually to be radiolabeled with technetium-99m. This solution is allowed to incubate for several hours (usually over 15 hours) in the absence of oxygen and at room temperature

  14. Technetium 99-m labeled radio-diagnostic agents employing stannous tartrate and method of preparation

    International Nuclear Information System (INIS)

    Molinski, V.J.; Wilczewski, J.A.

    1976-01-01

    A method of preparing improved technetium-99m labeled radiodiagnostic agents by reducing technetium-99m with stannous tartrate. Such radiodiagnostic agents are useful in scintigraphic examinations of the bone and lung. 31 claims, no drawings

  15. Monoclonal anti-elastin antibody labelled with technetium-99m

    International Nuclear Information System (INIS)

    Oliveira, Marcia B.N. de; Silva, Claudia R. da; Araujo, Adriano C. de; Bernardo Filho, Mario; Porto, Luis Cristovao M.S.; Gutfilen, Bianca; Souza, J.E.Q.; Frier, Malcolm

    1999-01-01

    Technetium-99m ( 99m Tc) is widely employed in nuclear medicine due to its desirable physical, chemical and biological properties. Moreover, it is easily available and normally is inexpensive. A reducing agent is necessary to label cells and molecules with 99m Tc and stannous chloride (Sn C L 2 ) is usually employed. Elastin is the functional protein component of the elastic fiber and it is related with some diseases such as arteriosclerosis, pulmonary emphysema and others. The present study refers to the preparation of the 99m Tc labeled monoclonal anti-elastin antibody. The monoclonal antibody was incubated with an excess of 2-iminothiolane. The free thiol groups created, were capable of binding with the reduced technetium. Labeling was an exchange reaction with 99m Tc-glucoheptonate. The labeled preparation was left at 4 deg C for one hour. Then, it was passed through a Sephadex G50 column. Various fractions were collected and counted. A peak corresponding to the radiolabeled antibody was obtained. Stability studies of the labelled anti-elastin were performed at 0,3 6, 24 hours, at both 4 deg C or room temperature. The biodistribution pattern of the 99m Tc-anti-elastin was studied in healthy male Swiss mice. The immunoreactivity was also determined. An useful labeled-anti-elastin was obtained to future immunoscintigraphic investigations. (author)

  16. The retention mechanism of technetium-99m-HM-PAO

    DEFF Research Database (Denmark)

    Neirinckx, R D; Burke, J F; Harrison, R C

    1988-01-01

    Preparations of d,l- and meso-hexamethylpropyleneamine oxime (HM-PAO) labeled with technetium-99m were added to rat brain homogenates diluted with phosphate buffer (1:10). The conversion of d,l-HM-PAO to hydrophilic forms took place with an initial rate constant of 0.12 min-1. Incubation of the b......Preparations of d,l- and meso-hexamethylpropyleneamine oxime (HM-PAO) labeled with technetium-99m were added to rat brain homogenates diluted with phosphate buffer (1:10). The conversion of d,l-HM-PAO to hydrophilic forms took place with an initial rate constant of 0.12 min-1. Incubation....... This correspondence of values supports the notion that GSH may be important for the in vivo conversion of 99mTc-labeled HM-PAO to hydrophilic forms and may be the mechanism of trapping in brain and other cells. A kinetic model for the trapping of d,l- and meso-HM-PAO in tissue is developed that is based on data...

  17. Bleeding rates necessary for detecting acute gastrointestinal bleeding with technetium-99m-labeled red blood cells in an experimental model

    International Nuclear Information System (INIS)

    Thorne, D.A.; Datz, F.L.; Remley, K.; Christian, P.E.

    1987-01-01

    Proponents of [/sup 99m/Tc]sulfur colloid for GI bleeding studies argue that, although labeled red blood cells are useful for intermittent bleeding, they are not capable of detecting low bleeding rates. Studies of dogs with experimental GI bleeding have indicated bleeding rates of 0.05 ml/min can be detected with [/sup 99m/Tc]sulfur colloid. Since similar data in the dog model were unavailable for /sup 99m/Tc-labeled red blood cells, we undertook this study. To simulate lower GI bleeding, catheters were inserted into the bowel lumen. Each dog's blood was labeled with /sup 99m/Tc using an in vitro technique. Venous blood was then withdrawn and re-infused into the lumen of the bowel using a Harvard pump. Fourteen dogs were studied, ten receiving a bleeding rate from 4.6-0.02 ml/min in the descending colon and four with proximal jejunal bleeds of 0.20-0.02 ml/min. Bleeding rates of 4.6-0.2 ml/min were detected within 10 min in the colon and bleeding rates as low as 0.04 ml/min were seen by 55 min. Slower bleeding rates were not detected. Similar findings were noted for proximal jejunal bleeds. Based on the time of appearance, a minimum volume of approximately 2-3 ml labeled blood was necessary to detect bleeding. We conclude that /sup 99m/Tc-labeled RBCs are sensitive for low bleeding rates in the dog model. The rates are comparable to those described for [/sup 99m/Tc]sulfur colloid in this experimental setting. The time of appearance of activity is related to the bleeding rate

  18. Labeling of creatinine with technetium-99m

    Energy Technology Data Exchange (ETDEWEB)

    Yurt Lambrecht, F. [Ege Univ., Bornova, Izmir (Turkey). Dept. of Nuclear Applications, Inst. of Nuclear Sciences; Durkan, K. [Dokuz Eylul Univ., Buca, Izmir (Turkey). Chemistry Technicianship Program, Izmir Vocational School; Soylu, A. [Dokuz Eylul Univ., Narlidere, Izmir (Turkey). Dept. of Pediatrics, Medical Faculty

    2004-07-01

    Creatinine is a clinically important index of renal glomerular filtration rate. Urine creatinine levels can be used as a screening test to evaluate kidney function or can be part of the creatinine clearance test. In case of kidney dysfunction or muscle disorders the creatinine concentration in serum/plasma may rise to a higher value than in healthy body. Technetium- 99m has been used in nuclear medicine and in biomedical research to label molecular and cellular structures employed as radiotracers. {sup 99m}Tc is utilized to label molecules and cells, used as radiopharmaceuticals, and also to label biological species. It presents many desirable characteristics. SnCl{sub 2} method is frequently used as a reducing agent in the {sup 99m}Tc- labeling process. Creatinine metabolism might be investigated by using labeled {sup 99m}Tc- creatinine in healthy or uremic rats. (orig.)

  19. Preparation and quality control of technetium-99m radiopharmaceuticals

    International Nuclear Information System (INIS)

    Samuels, D.L.

    1978-11-01

    Appropriate procedures for the production and quality control of technetium-99m based radiopharmaceuticals in hospital radiopharmacy consistent with the recently published Australian Code of Good Manufacturing Practice are discussed

  20. Production technologies for molybdenum-99 and technetium-99m

    International Nuclear Information System (INIS)

    1999-02-01

    Technetium-99m (6.02 h) is the most widely used radioisotope in nuclear medicine, accounting for more than 80% of all diagnostic nuclear medicine procedures. It is almost exclusively produced from the decay of its parent 99 Mo. The present sources of 99 Mo are research reactors by using the (n,γ) nuclear reaction with natural Mo ( 98 Mo, ∼24%), resulting in inexpensive but low-specific activity 99 Mo, or by neutron-induced fission of 235 U, which results in expensive but high specific activity 99 Mo. This publication covers several aspects related to the production of 99 Mo and 99m Tc. The contributed papers reflect the current status of the technology and discuss potential alternative methodologies for the production of 99 Mo and 99m Tc for medical use. The first four papers address the technologies using nuclear reactors, including the description of a new method using an aqueous homogenous reactor core for production of fission 99 Mo and the latest development efforts to fabricate 235 U low enriched targets (LEU, 235 U). The next five papers discuss the potential of utilizing particle accelerators and assess the current status of the available nuclear data for the production of both, 99 Mo and 99m Tc with proton and deuteron beams. The last paper discusses a new technology based on gel system for the preparation of 99 Mo/ 99m Tc generators using low specific activity 99 Mo produced in research reactors by the neutron activation of natural and inexpensive molybdenum oxide targets. Each individual paper was indexed and abstracted

  1. Technetium-99m labeled radiodiagnostic agents and method of preparation

    International Nuclear Information System (INIS)

    1976-01-01

    A method of preparing improved technetium-99m labelled radiodiagnostic agents by reducing sup(99m)Tc-pertechnetate with stannous tartrate is given. Human serum albumine (HSA) and 1-hydroxyethylidene-1,1-disodiumphosphonate (HEDSPA), which are useful in scintigraphic examinations of the lung and bone, were labelled in this way

  2. Labelling of metaiodobenzylguanidine (MIBG) with Technetium-99m radionuclide

    International Nuclear Information System (INIS)

    Maula Eka Sriyani; Dini Natanegara; Aang Hanafiah Ws

    2015-01-01

    Various neuroendocrine tumors and their metastases are able to localized and staged by Metaiodobenzylguanidine (MIBG). MIBG is a molecule that has a chemical structure similarities with noradrenaline in the adrenal. The research on 131 I-MIBG has been successfully conducted in the tumor imaging. This research of preparing 99m Tc-MIBG that will be used as a diagnostic agent for adrenal tumors was carried out. MIBG labeling activities with technetium-99m radionuclide were carried out through labeling of MIBG with technetium-99m and radiochemical purity analysis. The labeling of MIBG was carried out using both direct and indirect methods with diethylene triamine pentaacetic acid (DTPA) as a co-ligand. Determination of 99m Tc-MIBG labeling efficiency was performed using paper chromatography with Whatman 3MM/dried acetone and Whatman 31ET/acetonitrile 50%. The results of labeling efficiency using the indirect method with DTPA as a co-ligand was obtained 93.44 ± 1.93%, which the concentration of MIBG was 2 mg/0.5 mL H 2 O, concentration of co-ligand was 37,5 μg of SnCl 2 .2H 2 O and DTPA of 1,125 mg at pH 6.5 for 15 minutes incubation in the room temperature ( 25 °C). (author)

  3. An introduction to technetium-99m generators

    International Nuclear Information System (INIS)

    Abrashkin, S.

    1984-02-01

    The role played by technetium-99m generators in diagnostic medicine, their physical and chemical fundamentals and their main technical characteristics are discussed. This report is intended as a general introduction to a group of reports which summarize the work done on the development and production of the generators, and research on the chemical and physical aspects of the generator systems

  4. Fast technetium Eigen-colloid determination: preparative CPC combined with suspension liquid scintillation

    International Nuclear Information System (INIS)

    Breynaert, E.; Maes, A.

    2005-01-01

    -192. [2] Mang'era, K., et al., Synthesis and evaluation of the 99m Tc-complexes of -cysteine acetyl-di-glycine (a hybrid of MAG3 and -EC) and of -[beta]-homocysteine acetyl-di-glycine. Nuclear Medicine and Biology, 2000. 27(8): p. 781-789. [3] Sekine, T., et al., Radiolytic formation of Tc(IV) oxide colloids. Radiochimica Acta, 2002. 90(9- 11): p. 611-616. [4] Maes, A., et al., Evidence for the Formation of Technetium Colloids in Humic Substances by X-Ray Absorption Spectroscopy. Environmental Science and Technology, 2004. 38(7): p. 2044-2051. [5] Ben Said, K., et al., Gamma radiation effects on potassium pertechnetate in carbonate media. Applied Radiation and Isotopes, 2001. 54(1): p. 45-51. [6] Vichot, L., et al., XAS study of technetium(IV) polymer formation in mixed sulphate/chloride media. Radiochimica Acta, 2002. 90(9-11): p. 575-579. (authors)

  5. Ligand-free, protein-bound technetium-99m. Evidence for tumour localisation

    International Nuclear Information System (INIS)

    Jakovljevic, A.C.; Pojer, P.M.

    1984-11-01

    An hypothesis that cations accumulate in tumours independent of ligand is tested. A preparation of technetium-99m known to be ligand-free (that is, the technetium is protein bound and no other ligand is injected) has been shown to accumulate in a T-cell lymphoma

  6. Quantitative radiocardiography by single-probe counting using sup(99m)technetium albumin

    International Nuclear Information System (INIS)

    Man in 't Veld, A.J.; Wenting, G.J.; Verhoeven, R.P.; Schalekamp, M.A.D.H.

    1978-01-01

    Quantitative radiocardiography with sup(99m)Technetium albumin, using a single probe for percordial counting of radioactivity is a non-invasive technique to measure cardiac output. sup(99m)Technetium pertechnetate is bound to albumin by electrolytic complexation. Preparations of sup(99m)Technetium albumin showed small percentages of free radioactivity. In-vivo stability of the complex was confirmed by comparison with distribution volumes of 131 Iodine albumin and sup(113m)Indium transferrin. The isotope dilution cardiac output technique was validated by comparison with a classical indocyanine green dilution method. Results obtained by peripheral intravenous injection of the isotope were not different from those after intracardiac injection. Exact localization of the collimator over the heart was not critical. Duplicate measurements showed good reproducibility. Examples of serial measurements in patients with hyperthyroidism, primary aldosteronism and essential hypertinsion are given. The method is reliable, accurate and safe and causes no discomfort to the patient. (C.F.)

  7. Advances in technetium chemistry towards 99mTc receptor imaging agents

    International Nuclear Information System (INIS)

    Johannsen, B.; Spies, H.

    1997-01-01

    The development of the chemistry of technetium and its non-radioactive surrogate rhenium has been prompted by the trends and needs of nuclear medicine, which predominantly uses 99m Tc radiopharmaceuticals for a broad range of diagnostics. Technetium-99m is the ideal radioisotope for tomographic single-photon emission tomography (SPECT) imaging due to its nuclear properties (6.2 h, E γ 140 keV) and ready availability through generator systems. Transition metals offer many opportunities for designing molecules by modifying the environment around the core, allowing certain biological properties to be imposed upon the molecule. Whereas research in the past was mainly concerned with biological properties that allow relatively unspecific functional imaging, as in brain or myocardium perfusion studies, nuclear medicine is now requiring more and more biochemical information on low capacity, high specificity targets. Many research groups have become involved in the search for new technetium-based compounds, called the third generation of 99m Tc radiopharmaceuticals, that employ the principles of modern pharmacology to achieve biochemical specificity. There has been considerable interest in imaging CNS and other receptors with 99m Tc receptor-binding ligands. Such a 99m Tc CNS receptor-imaging agent is currently not yet in use because of the significant hurdles to be overcome in attaining this ambitious goal. However, some Tc and Re complexes of remarkable affinity in vitro, and the first high-affinity 99m Tc probes able to label the dopamine transporter in the brain by SPECT imaging prove the feasibility of this approach. (Author)

  8. Measurement of glomerular filtration rate in children using technetium-99m diethylenetriamine penta-acetic acid

    International Nuclear Information System (INIS)

    Aaronson, I.A.; Mann, M.D.

    1985-01-01

    During the past 5 years, we have measured the glomerular filtration rate (GFR) by the slope-clearance method using technetium-99m diethylenetriamine penta-acetic acid technetium-99m-DTPA in 130 infants and children. The results in 22 children have been compared with inulin clearance, and a very good correlation between the two methods of measurement of GFR was demonstrated (r = 0,9616; P less than 0,0001). This study provides further evidence that technetium-99m-DTPA is a satisfactory agent for the clinical measurement of GFR in children

  9. Study on liver scintigram using sup(99m)Tc-Sn colloid

    International Nuclear Information System (INIS)

    Nagase, Katsuya; Maruo, Kuninobu

    1975-01-01

    First of all, the liver scintigram was taken using 198 Au-colloid in cases of liver diseases, especially cases which seemed to have morphological changes in the liver. Of these cases, in cases which were found to have lesions the liver scintigram was subsequently taken using sup(99m)Tc-Sn colloid. In addition, in order to compare the state of lesions in both liver scintigrams with 198 Au-colloid and sup(99m)Tc-Sn colloid, ultrasonic tomogram was taken at each time. The scintigram using sup(99m)Tc-Sn colloid seemed to more clearly reveal the state of lesions and their sizes in the thin liver regions, especially the right border, the lower border and the left lobe in the liver, compared with 198 Au-colloid scintigram. The lesions in the thick liver tissues, especially the central right lobe, sometimes became unclear using sup(99m)Tc-Sn colloid. Therefore, 198 Au-colloid seemed to be available in these lesions. The scintigram using sup(99m)Tc-Sn colloid was found more useful for the diagnosis of lesions of patients with liver, cirrhosis whom the uptake rate of 198 Au-colloid is poor, compared with 198 Au-colloid scintigram. (Namekawa, K.)

  10. Clinical comparison of technetium-99m-EC, technetium-99-m-MAG3 and Iodine-131-OIH in renal disorders

    International Nuclear Information System (INIS)

    Kabasakal, L.; Turoglu, T.; Oensel, C.

    1995-01-01

    Technetium-99m-ethylenedicysteine has recently been developed for renal function studies. The pharmacokinetics of 99m Tc-EC were studied by constant infusion technique and compared with 99m Tc-MAG3 and 131 I-OIH in 11 patients with various renal disorders. After giving a 7.4 MBq 131 I-OIH and 90-110 MBq 99m Tc-EC or 99m Tc-MAG3 bolus, a constant infusion (MBq/ml) 99m Tc--agent and 0.07 MBq/m 131 I-OIH was started. Sixteen blood and five urine samples were obtained over three hr. The renal clearance of 99m Tc-EC was higher than than of 99m Tc-MAG3. The 99m Tc-EC/OIH and 99m Tc-MAG3/OIH ratios were 0.75 ± 0.05 and 0.55 ± 0.10 (p=0.00087), respectively. The distribution volume of 99m Tc-EC was also higher than that of 99m Tc-MAG3 (15722 ± 4644 and 9509 ± 2788 ml/1.73m 2 , respectively; p=0.072). The 99m Tc-EC/OIH and 99m Tc-MAG/OIH distribution volume ratios were 1.03 ± 0.14 and 0.55 ± 0.10, respectively (p = 0.0003). The 60-min excretion values of 99m Tc-EC and 99m Tc-MAG3 were compared to that of OIH. The 99m Tc-EC/OIH and 99m Tc-MAG3/OIH excretion ratios were 0.96 ± 0.06 and 1.07 ± 0.10, respectively (p=0.162). The protein binding of 99m -EC and OIH were found to be 34% ±4 and 66% ±5, respectively (p 99m Tc-EC was negligible (3% ±1.2) in comparison to OIH (27% ±3; p 99m Tc-EC. This agent has good potential for renal function evaluation. 32 refs., 5 tabs

  11. Labelling of Klebsiella pneumoniae with technetium-99m: a preliminary communication

    International Nuclear Information System (INIS)

    Bernardo Filho, M.; Pereira, J.A.A.; Boasquevisque, E.M.

    1986-01-01

    The labeling of Klebsiella pneumoniae with technetium-99m (Tc-99m) seems to depend on the stannous ion (Sn ++ ) concentration. Starting at 3μg/ml of this ion is the suspension fluid an uptake of Tc-99m close to 90% was observed. The labeling is apparently strong, since the eluation of Tc-99m, after incubation of the tagged culture, in a water-bath at 37 0 C for several hours, was very weak. The viability of the culture was unaltered after treatment with tin and Tc-99m. (Author) [pt

  12. The impact of technetium-99m-radiopharmaceuticals' design on their biological behavior

    International Nuclear Information System (INIS)

    Jankovic, D.Lj.; Djokic, D.Dj. . E-mail address of corresponding author: drinaj@vin.bg.ac.yu; Jankovic, D.)

    2005-01-01

    The coordination has a great and not always predictable impact on the in-vivo behaviour of the small molecule into which the technetium-bearing chelate units is integrated. The different valence state of technetium in the complexes with some ligands changes the properties of these complexes, such as physico-chemical parameters and biological behaviour. The change of their biological behaviour has a great impact on quality of imaging study and on radiation dose to the patient. The results of the labelling of DPD and EHIDA with 99mTc(I) and their biological behaviour, in comparison with the same one for 99mTc(III)-DPD and 99mTc(III)-EHIDA complexes, confirmed that different oxidation state of 99mTc make possible forming variety of complexes with quite a different and unexpected biological behaviour. (author)

  13. Cyclotron Production of Technetium-99m

    Science.gov (United States)

    Gagnon, Katherine M.

    Technetium-99m (99mTc) has emerged as the most widely used radionuclide in medicine and is currently obtained from a 99Mo/ 99mTc generator system. At present, there are only a handful of ageing reactors worldwide capable of producing large quantities of the parent isotope, 99Mo, and owing to the ever growing shutdown periods for maintenance and repair of these ageing reactors, the reliable supply 99mTc has been compromised in recent years. With an interest in alternative strategies for producing this key medical isotope, this thesis focuses on several technical challenges related to the direct cyclotron production of 99mTc via the 100Mo(p,2n)99mTc reaction. In addition to evaluating the 100Mo(p,2n)99mTc and 100Mo(p,x)99Mo reactions, this work presented the first experimental evaluation of the 100Mo(p,2n) 99gTc excitation function in the range of 8-18 MeV. Thick target calculations suggested that large quantities of cyclotron-produced 99mTc may be possible. For example, a 6 hr irradiation at 500 μA with an energy window of 18→10 MeV is expected to yield 1.15 TBq of 99mTc. The level of coproduced 99gTc contaminant was found to be on par with the current 99Mo/99mTc generator standard eluted with a 24 hr frequency. Highly enriched 100Mo was required as the target material for 99mTc production and a process for recycling of this expensive material is presented. An 87% recovery yield is reported, including metallic target preparation, irradiation, 99mTc extraction, molybdate isolation, and finally hydrogen reduction to the metal. Further improvements are expected with additional optimization experiments. A method for forming structurally stable metallic molybdenum targets has also been developed. These targets are capable of withstanding more than a kilowatt of beam power and the reliable production and extraction of Curie quantities of 99mTc has been demonstrated. With the end-goal of using the cyclotron-produced 99mTc clinically, the quality of the cyclotron

  14. The Clinical usefulness of 99mTc HMPAO Leukocyte/99mTc phytate bone marrow scintigraphy for diagnosis of prosthetic knee infection: A preliminary study

    International Nuclear Information System (INIS)

    Jung, Kyung Pyo; Park, Ji Sun; Lee, Ah Young; Choi, Su Jung; Lee, Seok Mo; Bae, Sang Kyun

    2012-01-01

    The preferred radionuclide imaging procedure for diagnosing prosthetic joint infection is combined radiolabeled leukocyte/ 99mT c sulfur colloid bone marrow scintigraphy, which has an accuracy of over 90%. Unfortunately, sulfur colloid is no longer available in South Korea. in this study, we evaluated the usefulness of 99mT c phytate, a substitute for 99mT c sulfur colloid, when combined with radiolabeled leukocyte scintigraphy in suspected prosthetic knee infections. Eleven patients (nine women, two men; mean age 72±6 years) with painful knee prostheses and a suspicion of infection underwent both 99mT c phytate bone marrow scintigraphy (BMS). The combined images were interpreted as positive for infection when radioactivity in the LS at the sits of clinical interest clearly exceeded that of the BMS (discordant); they were interpreted as negative when the increased activity in the LS was consistent with an increased activity in the BMS(concordant). The final diagnosis was made with microbiological or intraoperative findings and a clinical follow up of at least 12 months. Five of eleven patients were diagnosed as having an infected prosthesis. The overall sensitivity, specificity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of the combined LS/BMS were 100%, 83%, 83%, 100% and 91%, respectively. We find that combined 99mT c HMPAO LS/ 99mT c phytate BMS shows comparable diagnostic performance to other studies utilizing sulfur colloid. Combined 99mT c HMPAO LS/ 99mT c phytate BMS is therefore expected to be an acceptable alternative to combined radiolabeled LS/ 99ms ulfur colloid BMS for diagnosing prosthetic knee infections

  15. 3. Congress of the SA Society of nuclear medicine: Technetium-99m technology

    International Nuclear Information System (INIS)

    Beyers, M.

    1988-08-01

    The Atomic Energy Corporation of SA Limited have been engaged in the manufacture of radioisotopes since 1967, shortly after the SAFARI-1 reactor at Pelindaba was commissioned. Since then the use of radioisotopes in South Africa has grown rapidly and at present 95% of the in vivo diagnostic radioisotopes (radiopharmaceuticals) utilized in nuclear medicine are manufactured locally. Because radioisotopes are applied mainly in sophisticated chemically or mechanically processed forms, production requires not only a skilled production team, but also the appropriate facilities for the manufacture of high-quality products which comply with the necessary safety standards. Compliance with such standards is especially important for the routine production of radiopharmaceuticals for use in nuclear medicine. Over the past 20 years technetium-99m has achieved a dominant position among the diagnostic tools in modern nuclear medicine.The scope of nuclear medicine is expanding continuously and its future lies primarily in the development of new organspecific technetium-99m radiodiagnostic agents. Many improvements and changes have been made to Tc-99m generators, the major source of Tc-99m, since they were introduced to nuclear medicine in the late 1950's. The new Peltek-F sterile Tc-99m generator developed by the Isotope Production Centre is a symbol of progress made. In order to commemorate the launching of the new Peltek-F technetium-99m generator during August 1988 it was decided to publish six papers that were presented at the Third Congress of the Society of Nuclear Medicine held at Bloemfontein during the period 15 - 17 August 1988 by members of the Isotope Production Centre. This will serve as a useful reference on various aspects of technetium-99m technology and will stimulate the use of this product as well as new research in this field

  16. Renal 99M-technetium dimercaptosuccinic acid scintigraphy

    International Nuclear Information System (INIS)

    Ajdinovic, B.; Jaukovic, L.; Jankovic, Z.; Krstic, Z.

    2004-01-01

    99m-Technetium dimercaptosuccinic acid (99mTc-DMSA) whose ligand was used as a radioprotective agent and as a chelating compound for metal poisoning was reported to be an excellent renal imaging agent. As 99mTc-DMSA concentrates actively in the proximal convoluted tubule, it gives an image functional renal mass. Its integrity is dependent upon several factors, predominently intrarenal blood flow and intact enzyme function.Considering low radiation dose delivered by 99mTc DMSA and wide pediatric use of this radiopharmaceutical we calculate abnormal findings incidence (%).Results of 592 99m Tc-DMSA renal scintigraphy (348 children), which were classified as: 1. normal, 2. probably normal, 3. equivocal, 4. probably abnormal, 5. abnormal, are presented.Normal results were found in 269 patients (45,4%), 25% of whom was normal and 75% probably normal. Equivocal findings were found in 47 patients (7,9%). Abnormal results were presented in 276 patients (82% abnormal, 18% probably abnormal).The highest abnormal findings incidence was found in patients with congenital anomaly (88%), calculosis (87%) and policystic renal disease (79,3%). The lowest abnormal findings percentage was present in patients with urinary tract infection (12,9%) and arterial hypertension (17,3%)The role 99mTc-DMSA renal scintigraphy in pathology is clear in pyelonephrifis, hydronephrotic kidneys, and pediatric disease (urinary tract infections, congenital anomalies) and is confirmed by our results. (authors)

  17. Diagnostic value of with 111In-oxine or 99mTc-sulfur colloid labelled leukocytes in patients with infections following femoral fractures and implantation of hip joint endoprostheses, resp

    International Nuclear Information System (INIS)

    Kostadinowa, I.; Dontschew, M.; Dojtschinov, A.; Kynew, W.; Kowatschewa, S.; Medizinische Hochschule, Pleven

    1990-01-01

    Scintigraphy with leukocytes, labelled with 99m Tc-sulfur colloid or 111 In-oxine, in 41 patients with suspected inflammation in endoprothetic hip joints (n = 23) or infectious complications after femoral fracture (n = 18) has shown to be a highly specific and useful tool in orthopedic routine diagnosis. (author)

  18. Technetium-99m ceftizoxime kit preparation

    International Nuclear Information System (INIS)

    Diniz, Simone Odilia Fernandes; Siqueira, Cristiano Ferrari; Nelson, David Lee; Cardoso, Valbert Nascimento

    2005-01-01

    The aim of this work was to prepare a kit of 99 m Tc-ceftizoxime ( 99m Tc-CFT), with stability and biological activity preserved, able to identify a septic focus (E. coli) in the experimental infection model in rats. The preparation of the CFT kit involved the use of lyophilized solutions containing the antibiotic ceftizoxime and the sodium dithionite reducing agent (6.0 mg/m L). After lyophilization, the kit was reconstituted with 1.0 mL of sodium 99m Tc pertechnetate solution (Na 99m Tc O 4- ) with an activity of 370 MBq. The solution was boiled for 10 min and filtered through a cellulose ester filter. The labeling efficiency was on the order of 92%, remaining stable for six hours and the kit remained stable for two months. The biological activity of the 99m Tc-CFT was evaluated by diffusion in agar impregnated with E.coli and S. aureus. Seven Wistar rats, weighing from 200 to 250 g, were used for the development of the septic focus. After 24 hours from the induction of the infectious site (E.coli), the animals were anesthetized and 0.1 mL of 99m Tc-CFT (37 MBq) was injected into the tail veins of the animals. The images were obtained with a gamma camera one, two and six hours after injection and the regions of interest (ROIs) were calculated. The diameters of the inhibition halos for 99 m Tc-CFT were 27.16 ± 0.23 and 27.17 ± 0.20 for S.aureus and E.coli, respectively, while those for the unlabeled CFT were 30.4 ± 0.33 and 29.43 ± 0.26, respectively. The results for the biodistribution of 99m Tc-CFT in infected animals furnished a ratio of 1.97 ± 0.31, 2.10 ± 0.42 and 2.01 ± 0.42 for cpm-target/cpm-no target for the one, two and six-hour periods, respectively. The images showed a clear uptake of labeled antibiotic ( 99m Tc-CFT) by the infectious site during the experiment. The results attest to the viability of producing a kit with 99m technetium-labeled ceftizoxime for the investigation of infectious processes. (author)

  19. Labelling of leucocytes with colloidal technetium-99m-SnF2: an investigation of the labelling process by autoradiography

    International Nuclear Information System (INIS)

    Puncher, M.R.B.; Blower, P.J.

    1995-01-01

    Autoradiography of smears and frozen sections of labelled cell suspensions was used to study the distribution of radioactivity in and among blood cells labelled in either whole blood or leucocyte-rich plasma (LRP) with technetium-99m-SnF 2 colloid. The tracer proved selective for neutrophils: the labelling probability (relative to that for erythrocytes) for each cell type in LRP (mean of five samples) was: neutrophils, 9.4; lymphocytes, 3.7; monocytes, 3.0; eosinophils 1.4; erythrocytes, 1.0. When labelling was carried out in whole blood (five samples), 74.5%±8.3% of the cell-bound radioactivity was bound to erythrocytes, 13.6%±6.5% to neutrophils, and 11.9%±2.1% to lymphocytes, whereas in LRP (in which the leucocytes were only slightly outnumbered by erythrocytes), 76.5%±14.9% of radioactivity was neutrophil bound. Labelled cells in smear autoradiographs exhibited two distinct silver grain patterns, ''diffuse'', consistent with an intracellular radioactive particle (in neutrophils), and ''focal'', consistent with a cell surface-adhering particle in direct contact with the emulsion (in other leucocyte types and erythrocytes). The phagocytic inhibitor cytochalasin B neither reduced the proportion of labelled neutrophils nor altered the labelling pattern. Neutrophils were able to scavenge radioactivity from the surface of erythrocytes. It is concluded that neutrophils bind 99m Tc-SnF 2 intracellularly by phagocytosis, with high affinity; other cells become labelled at the cell surface reversibly and with lower affinity. This selectivity is high enough to permit predominantly leucocyte labelling in LRP but not in whole blood. (orig.)

  20. Technetium-99m labeling anti-amastigote polyclonal antibodies of Leishmania amazonensis

    International Nuclear Information System (INIS)

    Araujo, J.G.V.C.; Toledo, V.P.C.P.; Guimaraes, T.M.P.D.; Bernardo-Filho, M.; Simal, C.J.R.; Mota, L.G.; Diniz, S.O.F.; Cardoso, V.N.

    2002-01-01

    Anti-amastigote polyclonal antibody (IgG) was incubated with solutions of stannous chloride and sodium borohidride. After that, 3.7 MBq of technetium-99m ( 99m Tc) was added. A labeling yield of the antibody about 84% was obtained. After filtration of 99m Tc-IgG, the radiochemical purity increased from 84 to 95%. The labeling of IgG with 99m Tc did not modify the immunoreactivity of the antibody, since it was able to identify in vitro and in vivo the specific antigen of Leishmania amazonensis

  1. Quantitative hepatosplenic scintiscanning. Experimental and clinical studies to determine the contents of radioactivity in liver and spleen following administration of 99mTc sulfur colloid

    International Nuclear Information System (INIS)

    Feuchtinger, T.

    1983-01-01

    Hepatosplenic scintiscans were obtained from 78 patients following administration of 99mTc sulfur colloid using a double-head scanner and subjected to quantitative analysis. It was the aim of the study to assess the practicability of quantitative scintiscanning of liver and spleen, to define the range of generally acceptable, normal values for the concentration of 99mTc sulfur colloid in liver and spleen as well as to evaluate the clinical relevance of this method. The following values were determined to be normal: 4.7±1.5 for the liver: Spleen ratio; 31±3% for the proportion of the left hepatic lobe in total liver concentration; 68.7±5.4% and 17.4±3.6% for the active contents of liver and spleen, respectively. Quantitative scintiscanning constitutes a very sensitive method to detect transformation processes in the liver that are associated with a decreased liver: Spleen ratio and an increased ratio between the left hepatic lobe and the total organ. The method is unsuitable to assess pathological accumulation of the tracer substances. The question as to whether the use of the more time-consuming procedure of quantitative scintiscanning is justified by the additional diagnostic information gained remains to be investigated in further studies. (TRV) [de

  2. Determination of technetium-99 in environmental and radioactive waste samples

    International Nuclear Information System (INIS)

    Ferencova, M.; Peter Tkac, P.

    2007-01-01

    Technetium is known for its high mobility in a soil-water system in non-reducing aerobic condition and also high bio-availability for plants, because the most stable form of technetium in natural surface environment is pertechnetate which is highly soluble. The chemical form of technetium changes with environmental conditions. Concentration of technetium in the environment is very low, therefore many separation steps are needed for technetium determination. It has been developed a method for the routine determination of technetium-99 from environmental matrices and radioactive wastes using technetium-99m as an internal yield monitor. Technetium-99 is extracted from the soil samples with nitric acid. Many contaminants are co-precipitated with ferric hydroxide and technetium in the supernatant is pre-concentrated and further purified using anion exchange chromatography. Final separation of technetium was achieved by extraction with tetraphenylarsonium chloride in chloroform from sulphuric acid or pure water. The chemical yield is determined through the measurement of technetium-99m by scintillation counting system and the technetium-99 activity is measured using proportional counter after decay of the technetium-99m activity. Typical recoveries for this method are in the order 50-60 % (authors)

  3. Kit for preparing a technetium-99m myocardial imaging agent

    International Nuclear Information System (INIS)

    Woulfe, S.R.; Deutsch, E.A.; Dyszlewski, M.; Neumann, W.L.

    1992-01-01

    This patent describes a kit for preparing a technetium 99m myocardial imaging agent. It comprises a first vial containing a lyophilized pyrogen free, sterile mixture of an effective reducing agent and a first ligand having the following general formula: wherein the R 1 groups may be the same or different and are selected from the group consisting of hydrogen, hydroxy, C 1 - C 5 alkyl, C 1 - C 5 alkyl substituted by hydroxyl, ether, ester, amide, ketone, aldehyde and nitrile; the R 2 groups may be the same or different and are selected from the group consisting of hydrogen, hydroxy, C 1 - C 5 alkyl, C 1 - C 5 alkyl substituted by hydroxyl, ether, ester, amide, ketone, aldehyde, and nitrile; the X and Y groups may be the same or different and are selected from the group consisting of oxygen and sulfur; and n is equal to 1 or 2; and a second vial containing a lyophilized pyrogen free, sterile protected salt of a phosphine ligand

  4. The Hot Spot in Superior Vena Caval Obstruction Using 99m Technetium tin Colloid

    International Nuclear Information System (INIS)

    Kim, Byung Tae; Kwon, Kye Ik; Shin, Young Tae; Cho, Kyung Sam; Lee, Myung Chul; Cho, Bo Yeon; Koh, Chang Soon

    1981-01-01

    The hot spot on liver scan was demonstrated by many authors in various conditions such as SVC obstruction, Budd-Chiari syndrome, liver abscess, hemangioma of liver, hepatic venoocclusive diseases, IVC obstruction, and tricuspid insufficiency. And the appearance of hot spot in SVC obstruction is due to unusual collateral circulation. But there was no report of this hots pot on liver scan in our country. We have recently observed one patient with SVC obstruction who shows well-defined area of increased radioactivity between right and left lobe of liver on liver scan using 99m Tc-tin colloid, and demonstrated collateral circulations with RI venography using 99m Tc-O 4 . The injection site of radiocolloid was left antecubital vein. This hot spot did not appear when the radiocolloid was injected into right leg vein. We report here this hoe spot on liver scan in SVC obstruction with review of some literatures.

  5. Effects of concurrent drug therapy on technetium /sup 99m/Tc gluceptate biodistribution

    International Nuclear Information System (INIS)

    Hinkle, G.H.; Basmadjian, G.P.; Peek, C.; Barker, K.K.; Ice, R.D.

    1982-01-01

    Drug interactions with /sup 99m/Tc gluceptate resulting in altered biodistribution were studied using chart review and animal tests. Charts of nine patients who had abnormal gallbladder uptake of technetium /sup 99m/Tc gluceptate during a two-year period were reviewed to obtain data such as concurrent drug therapy, primary diagnosis, and laboratory values. Adult New Zealand white rabbits were then used for testing the biodistribution of technetium /sup 99m/Tc gluceptate when administered concurrently with possibly interacting drugs identified in the chart review--penicillamine, penicillin G potassium, penicillin V potassium, acetaminophen, and trimethoprim-sulfamethoxazole. Chart review revealed no conclusive patterns of altered biodistribution associated with other factors. The data did suggest the possibility that the five drugs listed above might cause increased hepatobiliary clearance of the radiopharmaceutical. Animal tests showed that i.v. penicillamine caused substantial distribution of radioactivity into the gallbladder and small bowel. Minimally increased gallbladder radioactivity occurred when oral acetaminophen and trimethoprim-sulfamethoxazole were administered concurrently. Oral and i.v. penicillins did not increase gallbladder activity. Penicillamine may cause substantial alteration of the biodistribution of technetium /sup 99m/Tc gluceptate

  6. Production of 99mTc-anatomy sulfide colloid for lymphoscintigraphy

    International Nuclear Information System (INIS)

    Shabani, G. A.; Hamzeh, H.; Najafi, R.

    2002-01-01

    The lymphatic system provides one of the chief paths for the spread (metastasis) of cancer from one part of body to another. Hodgkin's diseases, lymphocytic leukemia, various metastatic diseases and many lymph ode disorders can be assessed by lymphoscintigraphy. Radionuclide lymphoscintigraphy has been used for many years to define the lymphatic drainage of melanoma. The most common radiopharmaceuticals used for lymphoscintigraphy are 99 mTc-Sc, 99 mTc-antimony sulfide colloid has been chosen between other colloids. For antimony sulfide colloid preparation, hydrogen sulfide gas was passed through D.E. until saturation. Antimony potassium tartrate is then added to the solution to form Sb 2 S 3 ol lide. The colloid was stabilized with P.V.P. Excess H 2 S was removed by bubbling with nitrogen. The preparation was then filtered through a 0.22 μm membrane filter and aliquots containing 1.017 mg Sb 2 S 3 were dispensed into the reaction vials. Labeling was accomplished by adding 99 mTcO 4 and HCl to the vial and then heating it at 100 deg C in boiling water bath for 10 min. The P H was adjust by adding a phosphate buffer. The radiochemical purity of 99 mTc-antimony disulfide colloid by I TLC-S G/normal saline was more than 95 percent. The amount of Sb in reaction vial was 0. 729 mg. The study demonstrated that our formulation of antimony-sulfide which has 0.0486 mg (Sb) in 0.2 ml of 99 mTc-Sb 2 S 3 colloid per patient (total volume after labeling with 99 mTc is 3 ml)

  7. A method for the preparation of lipophilic macrocyclic technetium-99m complexes

    International Nuclear Information System (INIS)

    Troutner, D.E.; Volkert, W.A.

    1991-01-01

    A procedure for the preparation of technetium complexes applicable as diagnostic radiopharmaceuticals is suggested and documented with 27 examples. Technetium-99m is reacted with a suitable complexant selected from the class of alkylenamine oximes containing 2 or 3 carbon atoms in the alkylene group. The lipophilic macrocyclic complexes possess an amine, amide, carboxy, carboxy ester, hydroxy or alkoxy group or a suitable electron acceptor group. (M.D.). 7 tabs

  8. Detection of esophageal ulcerations with technetium-99m albumin sucralfate

    International Nuclear Information System (INIS)

    Goff, J.S.; Adcock, K.A.; Schmelter, R.

    1986-01-01

    Technetium-99m albumin-sucralfate ([/sup 99m/Tc]Su) can be used to demonstrate peptic ulcer disease in man and animals. We evaluated the usefulness of [/sup 99m/Tc]Su for detecting various grades of esophagitis. [/sup 99m/Tc]Su adhered to the distal esophagus for up to 3 hr in five of six patients with esophageal ulcers but adhered to only two of nine with lesser degrees of esophagitis. No adherence was seen in five patients without esophagitis. Thus, [/sup 99m/Tc]Su may not be useful for detecting any but the most severe grade of esophagitis. Based on these results, we speculate that the previously documented beneficial effects of sucralfate on mild to moderate esophagitis may be due to other mechanisms besides adherence to the ulcerated mucosa

  9. Detection of esophageal ulcerations with technetium-99m albumin sucralfate

    Energy Technology Data Exchange (ETDEWEB)

    Goff, J.S.; Adcock, K.A.; Schmelter, R.

    1986-07-01

    Technetium-99m albumin-sucralfate ((/sup 99m/Tc)Su) can be used to demonstrate peptic ulcer disease in man and animals. We evaluated the usefulness of (/sup 99m/Tc)Su for detecting various grades of esophagitis. (/sup 99m/Tc)Su adhered to the distal esophagus for up to 3 hr in five of six patients with esophageal ulcers but adhered to only two of nine with lesser degrees of esophagitis. No adherence was seen in five patients without esophagitis. Thus, (/sup 99m/Tc)Su may not be useful for detecting any but the most severe grade of esophagitis. Based on these results, we speculate that the previously documented beneficial effects of sucralfate on mild to moderate esophagitis may be due to other mechanisms besides adherence to the ulcerated mucosa.

  10. Technetium-99m ceftizoxime kit preparation

    Energy Technology Data Exchange (ETDEWEB)

    Diniz, Simone Odilia Fernandes; Siqueira, Cristiano Ferrari; Nelson, David Lee; Cardoso, Valbert Nascimento [Minas Gerais Univ. Federal, Belo Horizonte, MG (Brazil). Faculdade de Farmacia]. E-mail: simone@farmacia.ufmg.br; Martin-Comin, Josep [Bellvitge Univ., Barcelona (Spain)

    2005-10-15

    The aim of this work was to prepare a kit of {sup 99}m Tc-ceftizoxime ({sup 99m} Tc-CFT), with stability and biological activity preserved, able to identify a septic focus (E. coli) in the experimental infection model in rats. The preparation of the CFT kit involved the use of lyophilized solutions containing the antibiotic ceftizoxime and the sodium dithionite reducing agent (6.0 mg/m L). After lyophilization, the kit was reconstituted with 1.0 mL of sodium {sup 99m} Tc pertechnetate solution (Na {sup 99m} Tc O{sub 4-}) with an activity of 370 MBq. The solution was boiled for 10 min and filtered through a cellulose ester filter. The labeling efficiency was on the order of 92%, remaining stable for six hours and the kit remained stable for two months. The biological activity of the {sup 99m} Tc-CFT was evaluated by diffusion in agar impregnated with E.coli and S. aureus. Seven Wistar rats, weighing from 200 to 250 g, were used for the development of the septic focus. After 24 hours from the induction of the infectious site (E.coli), the animals were anesthetized and 0.1 mL of {sup 99m} Tc-CFT (37 MBq) was injected into the tail veins of the animals. The images were obtained with a gamma camera one, two and six hours after injection and the regions of interest (ROIs) were calculated. The diameters of the inhibition halos for {sup 99}m Tc-CFT were 27.16 {+-} 0.23 and 27.17 {+-} 0.20 for S.aureus and E.coli, respectively, while those for the unlabeled CFT were 30.4 {+-} 0.33 and 29.43 {+-} 0.26, respectively. The results for the biodistribution of {sup 99m} Tc-CFT in infected animals furnished a ratio of 1.97 {+-} 0.31, 2.10 {+-} 0.42 and 2.01 {+-} 0.42 for cpm-target/cpm-no target for the one, two and six-hour periods, respectively. The images showed a clear uptake of labeled antibiotic ({sup 99m} Tc-CFT) by the infectious site during the experiment. The results attest to the viability of producing a kit with {sup 99m} technetium-labeled ceftizoxime for the

  11. Technical problems associated with the production of technetium Tc 99m tin(II) pyrophosphate kits

    International Nuclear Information System (INIS)

    Kowalsky, R.J.; Dalton, D.R.

    1981-01-01

    The amount of tin(II) required for adequate reduction, complexation, and stability of technetium Tc 99m pertechnetate in radiopharmaceutical kits, and methods of preventing the loss of tin(II) during formulation of these lyophilized kits are investigated. Tin(II) loss from stannous chloride solutions was studied under several conditions, including room air versus nitrogen atmospheres, during vial filling in a laminar-flow hood with samples frozen on dry ice versus samples at room temperature, during lyophilization, and during storage under refrigerated, ambient, and elevated temperatures. Various amounts of stannous chloride, ranging from 5 to 1000 microgram/ml, were used in formulating sodium pertechnetate Tc 99m kits containing 100 mCi technetium Tc 99m and 0.4 microgram total technetium. Samples were removed at various times; hydrolyzed technetium, pertechnetate, and technetium Tc 99m pyrophosphate were isolated on instant thin-layer chromatography-silica gel and quantified with a scintillation counter. The time necessary to deoxygenate distilled water by nitrogen purging was measured. Several sources of stannous chloride were assayed for tin(II) content. Tin(II) loss occurs rapidly in solution (15% in one hour) unless continuously protected with nitrogen, and during vial filling in a laminar-flow hood unless frozen with dry ice. No substantial loss of tin(II) was detected during lyophilization or during storage of lyophilized product at any of the three temperatures. A minimum of 400 microgram tin(II) was required to provide 90% technetium Tc 99m pyrophosphate at six hours after preparation. Adequate deoxygenation of small quantities (450 ml) of water was accomplished in less than one hour. Some stannous chloride salts were highly oxidized in the dry state, and only high-purity elemental tin wire gave acceptable yields of tin

  12. Technical effects of adding 1 % lidocaine to technetium sulfur colloid for sentinel lymphatic mapping in early breast cancer: analysis of data from a double-blind randomized controlled trial.

    Science.gov (United States)

    Arciero, Cletus A; Henry, Leonard R; Howard, Robin S; Peoples, George E; Bilchik, Anton J; Avital, Itzhak; Buckenmaier Iii, Chester C; Stojadinovic, Alexander

    2013-08-01

    A practice standard in sentinel lymph node (SLN) mapping in breast cancer is intradermal injection of technetium-99m sulfur colloid (Tc-99m), resulting in significant patient discomfort and pain. A previous randomized controlled trial showed that adding lidocaine to Tc-99m significantly reduced radioisotope injection-related pain. We tested whether 1 % lidocaine admixed with Tc-99m affects feasibility of SLN mapping. Between January 2006 and April 2009, 140 patients with early breast cancer were randomly assigned (1:1:1:1) to receive standard topical 4 % lidocaine cream and intradermal Tc-99m (control) or to one of three other study groups: topical placebo cream and injection of Tc-99m containing sodium bicarbonate (NaHCO3), 1 % lidocaine, or both. All SLN data were collected prospectively. Study groups were comparable for clinicopathological parameters. As previously reported, the addition of 1 % lidocaine to the radioisotope solution significantly improved patient comfort. Overall SLN identification rate in the trial was 93 %. Technical aspects of SLN biopsy were similar for all groups, including time from injection to operation, first SLN (SLN 1) gamma probe counts, ex vivo counts for SLN 1 and SLN 2, and axillary bed counts. SLN identification rates were comparable statistically: control (96 %), lidocaine (90 %), sodium bicarbonate (97 %), and sodium bicarbonate-lidocaine (90 %). The control group had a significantly higher SLN 2/SLN 1 ex vivo count ratio, and the number of SLNs detected was significantly reduced in the lidocaine versus no-lidocaine groups (p cancer is associated with fewer SLNs detected, but it does not appear to compromise SLN identification.

  13. Splenic scintigraphy using Tc-99m-labeled heat-denatured red blood cells in pediatric patients: concise communication

    International Nuclear Information System (INIS)

    Ehrlich, C.P.; Papanicolaou, N.; Treves, S.; Hurwitz, R.A.; Richards, P.

    1982-01-01

    Ten children underwent splenic imaging with heat-denatured red blood cells labeled with technetium-99m (Tc-99m DRBC). The presenting problems included the heterotaxia syndrome, recurrent idiopathic thrombocytopenic purpura following splenectomy, mass in the left posterior hemithorax, and blunt abdominal trauma. In nine patients, the presence or absence of splenic tissue was established. A splenic hematoma was identified in the tenth patient. All patients were initially scanned with Tc-99m sulfur colloid (Tc-99m SC), and were selected for Tc-99m DRBC scintigraphy only after the results of the SC scans failed to establish the clinical problem beyond doubt. The availability of kits containing stannous ions, essential for efficient and stable labeling of red blood cells with Tc-99m and requiring only a small volume of blood, make splenic scintigraphy in children a relatively simple and definitive diagnostic procedure, when identification of splenic tissue is of clinical importance

  14. Splenic scintigraphy using Tc-99m-labeled heat-denatured red blood cells in pediatric patients: concise communication

    Energy Technology Data Exchange (ETDEWEB)

    Ehrlich, C.P.; Papanicolaou, N.; Treves, S.; Hurwitz, R.A.; Richards, P.

    1982-03-01

    Ten children underwent splenic imaging with heat-denatured red blood cells labeled with technetium-99m (Tc-99m DRBC). The presenting problems included the heterotaxia syndrome, recurrent idiopathic thrombocytopenic purpura following splenectomy, mass in the left posterior hemithorax, and blunt abdominal trauma. In nine patients, the presence or absence of splenic tissue was established. A splenic hematoma was identified in the tenth patient. All patients were initially scanned with Tc-99m sulfur colloid (Tc-99m SC), and were selected for Tc-99m DRBC scintigraphy only after the results of the SC scans failed to establish the clinical problem beyond doubt. The availability of kits containing stannous ions, essential for efficient and stable labeling of red blood cells with Tc-99m and requiring only a small volume of blood, make splenic scintigraphy in children a relatively simple and definitive diagnostic procedure, when identification of splenic tissue is of clinical importance.

  15. Evaluation of the use of technetium Tc 99m diethylenetriamine pentaacetic acid and technetium Tc 99m dimercaptosuccinic acid for scintigraphic imaging of the kidneys in green iguanas (Iguana iguana).

    Science.gov (United States)

    Greer, Leah L; Daniel, Gregory B; Shearn-Bochsler, Valerie I; Ramsay, Edward C

    2005-01-01

    To evaluate the use of scintigraphy involving technetium Tc 99m diethylenetriamine pentaacetic acid ((99m)Tc-DTPA) or technetium Tc 99m dimercaptosuccinic acid ((99m)Tc-DMSA) for the determination of kidney morphology and function in green iguanas (Iguana iguana). 10 healthy iguanas weighing >1.6 kg. Renal scintigraphy was performed by use of (99m)Tc-DTPA in 6 of the iguanas and by use of (99m)Tc-DMSA in all 10 iguanas. After the injection of (99m)Tc-DMSA, scans were performed for each iguana at intervals during a 20-hour period. Renal biopsies were performed in all 10 iguanas after the final scintigraphic evaluation. In iguanas, the use of (99m)Tc-DTPA for renal scintigraphy was nondiagnostic because of serum protein binding and poor renal uptake of the isotope; mean +/- SD (99m)Tc-DTPA bound to serum proteins was 48.9 +/- 9.9%. Renal uptake of (99m)Tc-DMSA produced distinct visualization of both kidneys. Renal uptake and soft tissue clearance of (99m)Tc-DMSA increased over the 20-hour imaging period; mean +/- SD renal uptake of (99m)Tc-DMSA was 11.31 +/- 3.06% at 20 hours. In each of the 10 iguanas, ultrasonographic and histologic examinations of biopsy specimens from both kidneys revealed no abnormalities. Results indicate that the kidneys of iguanas can be evaluated scintigraphically by use of (99m)Tc-DMSA; this technique may be potentially useful for the diagnosis of renal failure in iguanas.

  16. An investigation into the technical feasibility of cyclotron production of technetium-99m

    International Nuclear Information System (INIS)

    Egan, G.F.; Lagunas-Solar, M.C.

    1994-01-01

    The role of technetium-99m in nuclear medicine is well established with 80 per cent to 90 per cent of all nuclear medicine studies utilising this isotope. Technetium-99m is currently produced from nuclear reactors via production of the parent radionuclide molybdenum-99. The reactor production of 99m Tc has both significant financial and environmental costs, with unresolved problems in the areas of radioactive waste disposal and reactor decommissioning. Recent scientific publications have indicated that medical quality 99m Tc may be produced using cyclotrons without having the associated problems of waste disposal and decommissioning. Further scientific research is now required to demonstrate the feasibility of this cyclotron production technique. A collaboration between the Cyclotron and PET Centre, Austin Hospital, the National Medical Cyclotron, ANSTO, Sydney, and the Crocker Nuclear Laboratory, University of California, Davis, USA has been proposed. The general objective of the proposed collaboration is to acquire additional scientific data to evaluate the 99m Tc cyclotron production method and to determine the feasibility of cyclotron technology for Australian nuclear medicine. 16 refs., 2 tabs

  17. Labelling of leucocytes with colloidal technetium-99m-SnF{sub 2}: an investigation of the labelling process by autoradiography

    Energy Technology Data Exchange (ETDEWEB)

    Puncher, M.R.B. [Biological Lab., Canterbury Univ. (United Kingdom); Blower, P.J. [Nuclear Medicine Dept., Kent and Canterbury Hospital, Canterbury (United Kingdom)

    1995-02-01

    Autoradiography of smears and frozen sections of labelled cell suspensions was used to study the distribution of radioactivity in and among blood cells labelled in either whole blood or leucocyte-rich plasma (LRP) with technetium-99m-SnF{sub 2} colloid. The tracer proved selective for neutrophils: the labelling probability (relative to that for erythrocytes) for each cell type in LRP (mean of five samples) was: neutrophils, 9.4; lymphocytes, 3.7; monocytes, 3.0; eosinophils 1.4; erythrocytes, 1.0. When labelling was carried out in whole blood (five samples), 74.5%{+-}8.3% of the cell-bound radioactivity was bound to erythrocytes, 13.6%{+-}6.5% to neutrophils, and 11.9%{+-}2.1% to lymphocytes, whereas in LRP (in which the leucocytes were only slightly outnumbered by erythrocytes), 76.5%{+-}14.9% of radioactivity was neutrophil bound. Labelled cells in smear autoradiographs exhibited two distinct silver grain patterns, ``diffuse``, consistent with an intracellular radioactive particle (in neutrophils), and ``focal``, consistent with a cell surface-adhering particle in direct contact with the emulsion (in other leucocyte types and erythrocytes). The phagocytic inhibitor cytochalasin B neither reduced the proportion of labelled neutrophils nor altered the labelling pattern. Neutrophils were able to scavenge radioactivity from the surface of erythrocytes. It is concluded that neutrophils bind {sup 99m}Tc-SnF{sub 2} intracellularly by phagocytosis, with high affinity; other cells become labelled at the cell surface reversibly and with lower affinity. This selectivity is high enough to permit predominantly leucocyte labelling in LRP but not in whole blood. (orig.)

  18. The role of Tc-99m IDA hepatobiliary and Tc-99m colloid hepatic imaging in primary biliary cirrhosis

    International Nuclear Information System (INIS)

    Aburano, T.; Yokoyama, K.; Shuke, N.; Kinuya, S.; Takayama, T.; Tonami, N.; Hisada, K.

    1991-01-01

    To assess the presence of primary biliary cirrhosis, 15 patients at various histopathologic stages were studied by Tc-99m IDA hepatobiliary and/or Tc-99m colloid hepatic imaging. In the earlier stages (I and II), seven of eight patients (88%) showed uniform hepatic retention of Tc-99m IDA. Of seven patients in the same stage, however, four (57%) showed no abnormality on Tc-99m colliod imaging. In three of these four negative patients (75%), uniform hepatic retention of Tc-99m IDA was noted. In the later stages (III and IV), all seven patients showed decreased clearance with or without delayed tracer appearance in the intestine and prominent hepatic retention on Tc-99m IDA imaging; with Tc-99m colloid imaging there was enlargement of the spleen and increased activity in the spleen and bone marrow. Thus, Tc-99m IDA imaging is considered to be more useful in revealing this functional disorder at the earlier stage of primary biliary cirrhosis and in evaluating progression from an earlier to a later stage of disease. Tc-99m colloid imaging also effectively evaluated progression

  19. Comparison study among methodologies of planar chromatography for radiochemical control of technetium-99m

    International Nuclear Information System (INIS)

    Monteiro, Elisiane de Godoy

    2012-01-01

    Radiopharmaceuticals are substances that have radioisotopes in their composition. About 95% of the procedures performed in nuclear medicine use radiopharmaceuticals with diagnostic purposes, and the Lyophilized Reagents (LR) labeled with Technetium-99m ( 99 mTc), obtained from 99 Mo/ 99 mTc generator, are the most one used. Quality Control represents the set of assays to be performed to assure that the product is adequate to its purpose. An important feature to be evaluated in 99m Tc radiopharmaceuticals is the radiochemical purity (% RqP) to quantify free pertechnetate ( 99 mTcO 4 - ) and technetium colloidal (99mTcO 2 ) mainly by paper chromatography (PC), thin layer (TLC) and High Performance Liquid Chromatography (HPLC). The objective of this work was to perform the comparison among the radiochemical control methodologies of LR labeled with 99m Tc, described in the United States Pharmacopoeia (USP) and European Pharmacopoeia (EP) and those used by IPEN. 99m TcO 4 - eluate and DISIDA, DMSA, DTPA, EC, ECD, GHA, MIBI, MDP, PIRO, SAH and Sn Coloidal LR were provided by IPEN-CNEN/SP. TLC-cellulose, TLC-SG.TLC-SG reverse phase, HPTLC-cellulose, HPTLC-SG (Merck) and ITLC-SG (Pall Corporation), W1MM, W3MM, W17M e W31ET (Whatman) chromatographic plates were used. The measurement of the radioactivity was done in a Perkin Elmer Cobra D-5002 gamma counter. LR were labeled to obtain 55,0 MBq mL 1 (1,5 mCi mL 1 ) of final radioactive concentration. The % 99m TcO 4 - , % 99m TcO 2 and % RqP were determined up to 4 hour labeling. From 11 LR, only EC and GHA have no radiochemical control methods in USP and EP. In USP and/or EP, DTPA, MDP, PIRO, SAH and Sn Coloidal methods use ITLC-SG; IPEN uses this chromatography plate in DISIDA, EC, ECD, GHA, PIRO, MIBI and SAH. As ITLC-SG had been out of production (recommended in 40, 70 and 41% of the USP, EP and IPEN methodologies, respectively), it was necessary to search alternatives to replace ITLC-SG plate in the radiochemical control

  20. A neutral lipophilic technetium-99m complex for regional cerebral blood flow imaging

    International Nuclear Information System (INIS)

    Narra, R.K.; Nunn, A.D.; Kuczynski, B.L.; DiRocco, R.J.; Feld, T.; Silva, D.A.; Eckelman, W.C.

    1990-01-01

    Technetium-99m-DMG-2MP (Chloro[bis[2,3-butanedionedioxime(1-)-0][2,3- butanedionedioximato (2-)-N,N',N double-prime,N'double-prime,N double-prime double-prime,N'double-prime double-prime] (2-methylpropyl borato (2-))technetium]), also known as SQ 32097 is a member of a family of neutral lipophilic compounds generally known as boronic acid adducts of technetium dioxime complexes (BATOs). After i.v. administration, the concentration of [ 99m Tc]DMG-2MP in various regions of the brain appears to be proportional to blood flow. In rats, 1.1% ID was in the brain at 5 min postinjection when the blood contained less than 3% ID. Over 24 hr excretion was 59% in the feces and 23% in the urine. The activity in monkey brain at 5 min was 2.8% ID and it cleared with a t1/2 of 86 min. Autoradiographs of monkey brain sections showed excellent regional detail with a gray/white ratio of 3.6 at 10 min. The distribution of [ 99m Tc]DMG-2MP in the monkey brain corresponds to the known cytoarchitectural pattern of cerebral glucose metabolism. The properties of [ 99m Tc]DMG-2MP make it a potentially useful agent for cerebral perfusion imaging in man

  1. Method of preparation of technetium-99m labelled radio-diagnostic agents and a stable non radio-active carrier

    International Nuclear Information System (INIS)

    1975-01-01

    A method of preparing improved technetium-99m labeled radiodiagnostic agents is described by reducing technetium-99m with stannous tartrate. Such radiodiagnostic agents are useful in scintigraphic examinations of the bone and lung

  2. 99m Technetium pyrophosphate myocardium scintigraphy. First results

    International Nuclear Information System (INIS)

    Toussaint, Paul.

    1976-01-01

    99m technetium pyrophosphate myocardium scintigraphy is a very recent examination technique. This work gives the results obtained on 61 patients. As a vector of the isotope, pyrophosphate has the advantage over polyphosphate of a fast bone uptake there it should be stressed that a 90 minute pause is necessary between the intraveinous injection of the isotope and the photographic recording so that the reading is not troubled by the labelled intracardiac blood pool image, an image quality criterion being the estimation of a good costal fixation which in fact appears sooner or later according to the subject. The role of pyrophosphate, chelator of calcium in fixation of the isotope on the myocardium, could be explained by the fast appearance of 'dense bodies', made up of calcium hydroxyapathice crystals, in the mitochondria of myocardium cells having undergone an irreversible necrotic process. The choice of 99 m technetium is based on its ease of use: 6 hour half-life, high-energy pure gamma emission at 140 keV. The fixed image studied under two incidences, front and left anterior oblique, is obtained from mobile images given by the scintillation camera used in connection with a data processing system. Several facts are underlined, explaining the disadvantages, advantages and indications of the method [fr

  3. Clinical usefulness of scintigraphy with 99mTechnetium phosphates in rhabdomyolysis

    International Nuclear Information System (INIS)

    Aizawa, Nobuyuki; Hara, Yoshikuni; Suzuki, Yutaka; Akashi, Tsunehiro; Kamei, Tetsumasa; Uchiyama, Fujio; Mitsui, Tamito; Yamazaki, Yuki.

    1990-01-01

    We performed bone scans with 99m Technetium phosphates in 15 cases of clinically suspected rhabdomyolysis admitted to Chigasaki Tokushukai Hospital. Whole body scans were performed within 5 days from the onset of illness or admission. Accumulation of the radioactivity in the skeletal muscle was revealed in 13 of the 15 cases and the involved muscle groups were visualized vividly. Etiologies of rhabdomyolysis were diverse, ranging from malignant syndrome to sepsis. Myocardial concentration was absent in all of the cases. Renal concentration of the isotope was seen in cases where the degree of rhabdomyolysis was higher and renal impairment was present. We conclude that 99m Technetium phosphate bone scan is useful in clinically suspected rhabdomyolysis as a diagnostic test and as a test to localize and quantitate the muscular involvement. (author)

  4. Extraosseous uptake of sup(99m)technetium methylene diphosphonate: Neuroblastoma or radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Sty, J R; Kun, L; Casper, J; Babbitt, D P [Wisconsin Univ., Milwaukee (USA). Dept. of Radiology

    1980-01-01

    A child with a ganglioneuroblastoma and tumor uptake of sup(99m)technetium methylene diphosphonate (sup(99m)Tc-MDP) is presented. After surgical removal of an encapsulated tumor and radiation therapy, an interval bone scan demonstrated the same presurgical abnormality. Awareness of abnormal uptake of sup(99m)Tc-MDP in irradiated renal tissue prevents interpreting radiation nephritis as recurrent tumor.

  5. Tc-99m tilmanocept versus Tc-99m sulfur colloid in breast cancer sentinel lymph node identification: Results from a randomized, blinded clinical trial.

    Science.gov (United States)

    Unkart, Jonathan T; Hosseini, Ava; Wallace, Anne M

    2017-12-01

    No prior trials have compared sentinel lymph node (SLN) identification outcomes between Tc-99m tilmanocept (TcTM) and Tc-99m sulfur colloid (TcSC) in breast cancer (BC). We report on the secondary outcomes from a randomized, double-blinded, single surgeon clinical trial comparing post-injection site pain between TcTM and TcSC. Patients were randomized to receive a preoperative single, peritumoral intradermal injection of TcTM or TcSC. The number of total, "hot", and blue nodes detected and removed were compared between groups. Fifty-two (27-TcSC and 25-TcTM) patients were enrolled and underwent definitive surgical treatment. At least one "hot" SLN was detected in all patients. Three (5.8%) patients had a disease positive-SLN. The total number of SLNs removed was 61 (mean 2.26 (standard deviation (SD) 0.90)) in the TcSC group and 54 (mean 2.16 (SD 0.90)) in the TcTM group, P = 0.69. The total number of "hot" nodes in the TcSC group was 1.96 (SD 0.76) compared to 2.04 (SD 0.73) in the TcTM group, P = 0.71. The number of identified SLNs did not differ significantly between TcTM and TcSC. Given that no significant technical advantages exist between the two agents, surgeons should choose a radiopharmaceutical based on cost and side effect profile. © 2017 Wiley Periodicals, Inc.

  6. Lymph node scintigraphy with sup(99m)Tc-rhenium colloid

    International Nuclear Information System (INIS)

    Mitsuhata, Naoki; Suyama, Bunzo; Matsumura, Yosuke; Ohmori, Hiroyuki

    1981-01-01

    Lymph node scintigraphy with sup(99m)Tc-rhenium colloid in evaluation of nodal involvement by urological malignancy were performed on twelve cases (4 bladder cancer, 3 prostatic cancer, 2 penile cancer and 3 testicular tumor). These cases had been examined the extent of disease on the basis of findings at pedal lymphangiography, urography, computed tomography or laparotomy. sup(99m)Tc-rhenium colloid in a volume of 0.2 ml (2 mCi) was injected into the first interdigital webs of each foot without local anesthesia. In one case of penile cancer radioactive colloid was directly injected into the glans penis and prepuce including tumor area. Our clinical experience reported here reveals that lymph node scintigraphy with sup(99m)Tc-rhenium colloid can provide a useful method of investigating the lymphatic system. This technique is reproducible and can be performed in poor risk patients or pediatric patients readily and safely. (author)

  7. Technetium-99m HMPAO labeled leukocytes in inflammation imaging

    International Nuclear Information System (INIS)

    Uno, Kimiichi; Yoshikawa, Kyousan; Imazeki, Keiko; Minoshima, Satoshi; Arimizu, Noboru

    1991-01-01

    Technetium-99m-HMPAO (Tc-99m-HMPAO) labeled leukocyte imaging was carried out in 19 patients at 3-5 hr after reinjection. There were no side effects noted. Tc-99m leukocyte images showed gall bladder, colon, kidney, and urinary bladder activity in normal distribution as a result of excretion of the eluted Tc-99m complex. They yielded a sensitivity of 93%, a specificity of 100% and an accuracy of 95%. They were correctly positive in 14 out of 19 cases. But one false negative case was seen in a patient with pyonephrosis showing a lack of renal function with decreased renal blood flow. It was concluded that they have some advantages over In-111 leukocyte images, but we have to consider the fact that the ureteral obstruction or the lack of renal function with decreased renal blood flow may result in a false positive or a false negative case. (author)

  8. Sensitivity of technetium-99m-d,1-HMPAO to radiolysis in aqueous solutions

    International Nuclear Information System (INIS)

    Tubergen, K.; Corlija, M.; Volkert, W.A.; Holmes, R.A.

    1991-01-01

    The sensitivity of technetium-99m- (99mTc) d,l-HMPAO to radiolytically induced dissociation in aqueous solutions was investigated. It was found that cobalt-60 (60Co) gamma irradiation of solutions containing 99mTc-d,l-HMPAO with only 1600 cGy reduced the lipophilic chelates' radiochemical purity (RCP) to 50%-60%. The radiolytic sensitivity of 99mTc-meso-HMPAO is significantly lower. The results indicate that radiolytically produced intermediates limit the in vitro stability of 99mTc-d,l-HMPAO

  9. Hepatobiliary scintigraphy with 99Tcsup(m)-HIDA and 99Tcsup(m)-sulphur colloid

    International Nuclear Information System (INIS)

    Pedersen, S.A.; Oster-Jorgensen, E.; Schoubye, J.; Odense Univ.

    1980-01-01

    The results of a study comparing the ability of 99 Tcsup(m)-sulphur colloid and 99 Tcsup(m)- HIDA to demonstrate circumsribed defects and obstruction of the biliary flow to the intestines are reported. As regards focal liver diseases, colloid scintigraphy (SC) had a nosographic sensitivity and specificity of 0.87 and 0.85, respectively. The corresponding figures for the HIDA scintigraphy were 0.40 and 0.92. Concerning the diagnosis of extrahepatic obstrtuction, sulphur colloid scintigraphy had a nosographic sensitivity and specificity of 0.31 and 0.94. The corresponding figures for HIDA scintigraphy were 0.69 and 0.84. The most frequent cause of false results was pattern of hepatocellular disease in sulphur colloid scans in patients with a longstanding biliary onbstruction. The second most frequent error was due to circumscribed defects in SC as well as in HIDA scans in patients with obstructive diseases and a high value of serum bilirubin. A third source of error was the pattern of an obstruction in HIDA scans in patients with focal diseases. The significance of the star pattern the sulphur colloid scan in patients with obstruction is stressed, as the significance of this pattern not has been evaluated previously. It is concluded that the two different scintigraphic methods are complementary tools in the examination of patients with liver diseases. (orig.) [de

  10. Automation drying unit molybdenum-zirconium gel radioisotope production technetium-99M for nuclear medicine

    International Nuclear Information System (INIS)

    Chakrova, Y.; Khromushin, I.; Medvedeva, Z.; Fettsov, I.

    2014-01-01

    Full text : Since 2001 the Institute of Nuclear Physics of the Republic of Kazakhstan has began production of radiopharmaceutical based on technetium-99m from irradiated reactor WWR-K of natural molybdenum, which allows to obtain a solution of technetium-99m of the required quality and high volume activity. In 2013 an automated system is started, which is unique and urgent task is to develop algorithms and software in Python, as well as the manufacture of certain elements of technological systems for automated production

  11. Extraosseous uptake of sup(99m)technetium methylene diphosphonate: Neuroblastoma or radiation therapy

    International Nuclear Information System (INIS)

    Sty, J.R.; Kun, L.; Casper, J.; Babbitt, D.P.

    1980-01-01

    A child with a ganglioneuroblastoma and tumor uptake of sup(99m)technetium methylene diphosphonate (sup(99m)Tc-MDP) is presented. After surgical removal of an encapsulated tumor and radiation therapy, an interval bone scan demonstrated the same presurgical abnormality. Awareness of abnormal uptake of sup(99m)Tc-MDP in irradiated renal tissue prevents interpreting radiation nephritis as recurrent tumor. (orig.) [de

  12. Evaluation of the liver scintigraphy with sup(99m)Tc-Sn-colloid, 2

    International Nuclear Information System (INIS)

    Kimura, Kazufumi; Nishimura, Tsunehiko; Takeda, Hiroshi; Furukawa, Toshiyuki; Kajiya, Fumihiko.

    1975-01-01

    Clinical significance of the liver scintigraphy with sup(99m)Tc-Sn-colloid was evaluated in comparison with those with 198 Au-colloid. The liver scintigrams with sup(99m)Tc-Sn-colloid and 198 Au-colloid were done in 36 cases of various hepatic diseases and RI accumulation curves in the liver and the spleen, and the blood disapearance curves were also obtained. The conclusions were as follows. The liver scintigrams with sup(99m)Tc-Sn-colloid proved to be more sensitive in the detection of tumors, especially, in the lower margin, left lobe and superficial layers of the liver than those with 198 Au-colloid. In all cases, including normal and cirrhotic subjects, visualizations of the spleen were seen on the scintigrams with sup(99m)Tc-Sn-colloid. In diffuse hepatic diseases, comparing both radiopharmaceuticals, the splenic accumulations were studied qualitatively and quantitatively. As a result, the ratio (spleen/liver) was thought to be useful for the differentiation of diffuse hepatic diseases concerned with splenic function and/or size. It was also shown that sup(99m)Tc-Sn-colloid was useful as a spleen scanning agent. The Tl/2 in the liver accumulation curves with sup(99m)Tc-Sn-colloid were not as clearly differentiated in the various hepatic diseases as those with 198 Au-colloid where those indexes were useful in the evaluation of liver functions. (auth.)

  13. The Clinical usefulness of {sup 99mT}c HMPAO Leukocyte/{sup 99mT}c phytate bone marrow scintigraphy for diagnosis of prosthetic knee infection: A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Kyung Pyo; Park, Ji Sun; Lee, Ah Young; Choi, Su Jung; Lee, Seok Mo; Bae, Sang Kyun [Inje Univ., Pusan Paik Hospital, Pusan (Korea, Republic of)

    2012-12-15

    The preferred radionuclide imaging procedure for diagnosing prosthetic joint infection is combined radiolabeled leukocyte/{sup 99mT}c sulfur colloid bone marrow scintigraphy, which has an accuracy of over 90%. Unfortunately, sulfur colloid is no longer available in South Korea. in this study, we evaluated the usefulness of {sup 99mT}c phytate, a substitute for {sup 99mT}c sulfur colloid, when combined with radiolabeled leukocyte scintigraphy in suspected prosthetic knee infections. Eleven patients (nine women, two men; mean age 72{+-}6 years) with painful knee prostheses and a suspicion of infection underwent both {sup 99mT}c phytate bone marrow scintigraphy (BMS). The combined images were interpreted as positive for infection when radioactivity in the LS at the sits of clinical interest clearly exceeded that of the BMS (discordant); they were interpreted as negative when the increased activity in the LS was consistent with an increased activity in the BMS(concordant). The final diagnosis was made with microbiological or intraoperative findings and a clinical follow up of at least 12 months. Five of eleven patients were diagnosed as having an infected prosthesis. The overall sensitivity, specificity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of the combined LS/BMS were 100%, 83%, 83%, 100% and 91%, respectively. We find that combined {sup 99mT}c HMPAO LS/{sup 99mT}c phytate BMS shows comparable diagnostic performance to other studies utilizing sulfur colloid. Combined {sup 99mT}c HMPAO LS/{sup 99mT}c phytate BMS is therefore expected to be an acceptable alternative to combined radiolabeled LS/{sup 99ms}ulfur colloid BMS for diagnosing prosthetic knee infections.

  14. Technetium-99m-Sestamibi in the diagnosis of acute chest pain

    International Nuclear Information System (INIS)

    Gilleece, T.; Salehi, N.; Better, N.

    1998-01-01

    Full text: A 45-year-old male was admitted to coronary care with a two-day history of recurrent chest pain. Despite maximal medical therapy, pain persisted. Examination and ECG with pain, were normal, suspicion of ischaemia was moderately high but coronary angiography was not immediately available. Technetium-99m-Sestamibi was prepared at the start of the day according to the standard preparation protocol (Du Pont). Coronary Care informed the Nuclear Medicine Department immediately the patient experienced a further episode of chest pain. Technetium-99m-Sestamibi was administered in coronary care, 4.30 minutes after being advised of the onset of further chest pain. Images were acquired 60 minute post-injection; 15 minutes after the patient had been given 200 mL of milk. A triple-headed gamma camera was used to acquire SPECT images over a 1200 arc, 30 frames of 30 seconds using a 64 x 64 matrix. The patient was laying prone with arms raised out of the field of view. Images showed a normal distribution of technetium-99m -Sestamibi throughout the myocardium. Due to ongoing clinical suspicion by the treating physician, coronary angiography was subsequently performed. This showed normal coronary arteries. Medical therapy was ceased and the patient discharged the next day. We concluded that the chest pain at the time of injection was not ischaemic. Previous trials had shown a 95% sensitivity for this method of diagnosing ischaemia. This method permits a novel and simple technique for diagnosing myocardial ischaemia and obviating the need for cardiac catheterization in this group of patients

  15. Evaluation of the liver scintigraphy with sup(99m)Tc-Sn-colloid, 1

    International Nuclear Information System (INIS)

    Kimura, Kazufumi; Kusumi, Yoshimi; Nishimura, Tsunehiko; Takeda, Hiroshi; Furukawa, Toshiyuki

    1975-01-01

    sup(99m)Tc-Sn-colloid, supplied by Dinabot Radioisotope Lab. in a kit ''Auto vial; Sn-colloid'', was compared with 198 Au-colloid as a liver scanning agent by the electrolysis method. The preparation procedure was short and very simple, and the labelling efficiency was more than 99.7% in the authors chromatographic studies. Sequential whole body and liver radioactivities after intravenous administration of sup(99m)Tc-Sn-colloid were measured for a period of 24 hours. Because radioactivity in the whole body and liver was diminished only by the decay of sup(99m)Tc. So, the excretion of sup(99m)Tc-Sn-colloid from the whole body and the liver was thought to be negligible. Phantom studies showed that tumor models of 2 cm in diameter in the superficial layers could be detected more cleary than those in the deep layers by using sup(99m)Tc-Sn-colloid. Using 2-3 mCi of sup(99m)Tc-Sn-colloid, a scintiphoto of 50,000 counts was taken in about ten seconds. So, it was possible to obtain motionless liver scintigrams with breath-holding. Blood disappearance curves of both colloids were measured by a scintillation counter and radioisotope accumulation curves in the liver and the spleen were measured by an Anger camera with data processing system. sup(99m)Tc-Sn-colloid was eliminated from the blood more rapidly than 198 Au-colloid and was accumulated in the liver more rapidly than 198 Au-colloid. The splenic uptake of the former exceeded that of the latter. As seen in these studies, the agents differ appreciably from each other in their behavior. These differences were discussed to be due to the character of the particle such as size, etc. And other reasons may lie in the differences of phagocytic activities of the liver and the spleen. (Evans, J.)

  16. Technetium-99m DTPA renal flow studies in Goldblatt hypertension

    International Nuclear Information System (INIS)

    Nally, J.V.; Clarke, H.S.; Windham, J.P.; Grecos, G.P.; Gross, M.L.; Potvin, W.J.

    1985-01-01

    Computer-assisted dynamic renal studies were performed on a group of 14 mongrel dogs before and after the induction of unilateral renal artery stenosis. Ninety-second technetium-99m diethylenetriaminepentaacetic acid ([/sup 99m/Tc]DTPA), 15-min [/sup 99m/Tc]DTPA, and 30-min iodine-131 orthoiodohippurate ([ 131 I]hippuran) time-activity curves were analyzed and correlated with reduction of renal blood flow as measured by electromagnetic flow probe and PAH clearance techniques. For blood flow reductions greater than 33%, the [/sup 99m/Tc]DTPA studies were judged diagnostic of unilateral renal artery stenosis in all cases, whereas the [ 131 I]hippuran time-activity curves were indicative of stenosis in only six of ten studies. Thus, in this model we find the computer-assisted 90-sec [/sup 99m/Tc]DTPA renal flow study to be superior to conventional [ 131 I]hippuran renography in the diagnosis of moderate-to-serve unilateral renal artery stenosis

  17. Preclinical evaluation of technetium 99m-labeled P1827DS for infection imaging and comparison with technetium 99m IL-8

    Energy Technology Data Exchange (ETDEWEB)

    Krause, Sabine [Bayer Schering Pharma AG, Global Drug Discovery, D-13342 Berlin (Germany); Rennen, Huub J.; Boerman, Otto C. [Radboud University, Nijmegen Medical Centre, 6500 HB Nijmegen (Netherlands); Baumann, Sabine; Cyr, John E.; Manchanda, Rajesh; Lister-James, John [Bayer Schering Pharma AG, Global Drug Discovery, D-13342 Berlin (Germany); Corstens, Frans C. [Radboud University, Nijmegen Medical Centre, 6500 HB Nijmegen (Netherlands); Dinkelborg, Ludger M. [Bayer Schering Pharma AG, Global Drug Discovery, D-13342 Berlin (Germany)], E-mail: sabine.krause@bayerhealthcare.com

    2007-11-15

    Background: The technetium 99 m ({sup 99m}Tc)-radiolabeled, leukocyte-avid peptide-glycoseaminoglycan complex, [{sup 99m}Tc]P1827DS, has been synthesized as an improved infection/inflammation imaging agent to [{sup 99m}Tc]P483H (LeukoTect, Diatide). In a phase I/II clinical trail, [{sup 99m}Tc]P483H images were equivalent to those obtained with {sup 111}In ex vivo labeled leukocytes. However, there was physiologic accumulation of radioactivity in the body that could hamper interpretation of the images. In this study, the potential of [{sup 99m}Tc]P1827DS for infection imaging was assessed in comparison with [{sup 99m}Tc]P483H and the well-described imaging agent [{sup 99m}Tc] hydrazinonicotinamide (HYNIC)-interleukin 8 (IL-8). Methods: The binding of [{sup 99m}Tc]P1827DS to human blood cell was studied in vitro. A rabbit Escherichia coli infection model was used to perform the biodistribution and imaging studies with [{sup 99m}Tc]P1827DS, [{sup 99m}Tc]P483H and [{sup 99m}Tc]HYNIC-IL-8. Results: [{sup 99m}Tc]P1827DS binds to leukocytes but not to erythrocytes. The leukocyte binding was not saturable up to an investigated concentration of 10 {mu}M. The accumulation of [{sup 99m}Tc]P1827/DS at the infection site strongly depends on the P1827/DS ratio and was optimal at a molar ratio of 10:1. [{sup 99m}Tc]P1827DS shows improved biodistribution over [{sup 99m}Tc]P483H with similar uptake at the infection site. Abscess uptake of [{sup 99m}Tc]HYNIC-IL-8 was approximately three times higher than that of [{sup 99m}Tc]P1827DS. [{sup 99m}Tc]HYNIC-IL-8 showed high accumulation in the kidneys, whereas [{sup 99m}Tc]P1827DS showed high lung uptake and slightly higher accumulation in the liver and spleen. Conclusion: [{sup 99m}Tc]P1827DS is a potential new inflammation imaging agent, which clearly visualized the abscess in the rabbit E. coli infection model and showed improved biodistribution compared to [{sup 99m}Tc]P483H. However, the infection uptake and biodistribution of

  18. Preclinical evaluation of technetium 99m-labeled P1827DS for infection imaging and comparison with technetium 99m IL-8

    International Nuclear Information System (INIS)

    Krause, Sabine; Rennen, Huub J.; Boerman, Otto C.; Baumann, Sabine; Cyr, John E.; Manchanda, Rajesh; Lister-James, John; Corstens, Frans C.; Dinkelborg, Ludger M.

    2007-01-01

    Background: The technetium 99 m ( 99m Tc)-radiolabeled, leukocyte-avid peptide-glycoseaminoglycan complex, [ 99m Tc]P1827DS, has been synthesized as an improved infection/inflammation imaging agent to [ 99m Tc]P483H (LeukoTect, Diatide). In a phase I/II clinical trail, [ 99m Tc]P483H images were equivalent to those obtained with 111 In ex vivo labeled leukocytes. However, there was physiologic accumulation of radioactivity in the body that could hamper interpretation of the images. In this study, the potential of [ 99m Tc]P1827DS for infection imaging was assessed in comparison with [ 99m Tc]P483H and the well-described imaging agent [ 99m Tc] hydrazinonicotinamide (HYNIC)-interleukin 8 (IL-8). Methods: The binding of [ 99m Tc]P1827DS to human blood cell was studied in vitro. A rabbit Escherichia coli infection model was used to perform the biodistribution and imaging studies with [ 99m Tc]P1827DS, [ 99m Tc]P483H and [ 99m Tc]HYNIC-IL-8. Results: [ 99m Tc]P1827DS binds to leukocytes but not to erythrocytes. The leukocyte binding was not saturable up to an investigated concentration of 10 μM. The accumulation of [ 99m Tc]P1827/DS at the infection site strongly depends on the P1827/DS ratio and was optimal at a molar ratio of 10:1. [ 99m Tc]P1827DS shows improved biodistribution over [ 99m Tc]P483H with similar uptake at the infection site. Abscess uptake of [ 99m Tc]HYNIC-IL-8 was approximately three times higher than that of [ 99m Tc]P1827DS. [ 99m Tc]HYNIC-IL-8 showed high accumulation in the kidneys, whereas [ 99m Tc]P1827DS showed high lung uptake and slightly higher accumulation in the liver and spleen. Conclusion: [ 99m Tc]P1827DS is a potential new inflammation imaging agent, which clearly visualized the abscess in the rabbit E. coli infection model and showed improved biodistribution compared to [ 99m Tc]P483H. However, the infection uptake and biodistribution of [ 99m Tc]P1827DS is not superior to that of [ 99m Tc]HYNIC-IL-8 in this animal model

  19. Technetium-99m-sestamibi scintigraphy in breast nodes; Estudo cintilografico de nodulos mamarios com tecnecio-99m-sestamibi

    Energy Technology Data Exchange (ETDEWEB)

    Pellini, Marcos Pinto; Fonseca, Lea Mirian Barbosa da [Universidade Federal, Rio de Janeiro, RJ (Brazil). Faculdade de Medicina; Balen, Jacir Luiz; Fabricio, Maria Ines Menescal [Universidade Federal, Rio de Janeiro, RJ (Brazil). Faculdade de Medicina. Inst. de Ginecologia; Amarante Junior, Jose Luiz de Medeiros

    1997-01-01

    The purpose was to was to determine if technetium-99m-sestamibi accumulates preferentially within the malignant palpable nodes of breast. Twenty-five patients, mean age 36.16 ({+-} 9.34) year, and without any other additional information, underwent breast scintigraphy and excisional biopsy. We had nineteen true-negative cases, four true-positive, two false-positive and none false-negative. Sensitivity, 100% specificity, 90.5%, accuracy, 92%; PPV, 66.7%, NPV, 100%. The four true positive were invasive intraductal carcinomas and one of them metastases in auxiliary lymph-nodes, confirmed in biopsy and well defined in scintigraphy. The two false-positives were a fibroadenoma with high cellularity and a fibrodisplasy surrounded by chronic inflammatory process. Two statistical tests were applied: chi-square and Fisher. Both rejected the antithesis at a confidence interval of 99% (p , 0.01) We concluded that technetium-99-sestamibi accumulates preferentially within the malignant nodes of breast. (author) 17 refs., 3 figs., 2 tabs.

  20. Functional studies of the oesophagus with sulfur-colloid of sup(99m)Tc and gamma-camera

    International Nuclear Information System (INIS)

    Veiga-Fernandes, F.; Costa, P.M.; Pinheiro, M.F.; Guerreiro, D.

    1982-01-01

    A scintiscanning technique which allows sequential detection and quantification of gastro-oesophageal reflux (GER), and study of the oesophageal emptying of a liquid and semi-solid food is presented. At first patients swallowed 5 ml of water containing 1 mCi sup(99m)Tc sulfur-colloid and oesophageal activity is recorded from an anterior view by a gamma-camera. Then, patients ingest 300 ml of water that clear the oesophagus and fill up the stomach. GER index is calculated according to the formula GER = (Ae - Ab)/Ag) x 100, where Ae is the activity in the oesophagus; Ab, is the background activity; and Ag is the gastric activity. GER index presented corresponds to a median of three determinations in upright, supine and supine position with abdominal pressure of 4 kilos. The oesophageal transit time of a semi-solid food in upright and supine position is registered 5 minutes after GER studies through two areas of interest which are positioned: one in the superior third and the other in the inferior third of the oesophagus. Normal GER reflux index was, 0.84 +- 0.37 in the upright position; 0.87 +- 0.43 in the supine position; and 0.90 +- 0.56 in the supine position plus abdominal pressure

  1. The Hot Spot in Superior Vena Caval Obstruction Using {sup 99m} Technetium tin Colloid

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byung Tae; Kwon, Kye Ik; Shin, Young Tae; Cho, Kyung Sam; Lee, Myung Chul; Cho, Bo Yeon; Koh, Chang Soon [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1981-03-15

    The hot spot on liver scan was demonstrated by many authors in various conditions such as SVC obstruction, Budd-Chiari syndrome, liver abscess, hemangioma of liver, hepatic venoocclusive diseases, IVC obstruction, and tricuspid insufficiency. And the appearance of hot spot in SVC obstruction is due to unusual collateral circulation. But there was no report of this hots pot on liver scan in our country. We have recently observed one patient with SVC obstruction who shows well-defined area of increased radioactivity between right and left lobe of liver on liver scan using {sup 99m}Tc-tin colloid, and demonstrated collateral circulations with RI venography using {sup 99m}Tc-O{sub 4}. The injection site of radiocolloid was left antecubital vein. This hot spot did not appear when the radiocolloid was injected into right leg vein. We report here this hoe spot on liver scan in SVC obstruction with review of some literatures.

  2. Uptake and localization of sup(99m)technetium-methylene-diphosphonate in bone

    International Nuclear Information System (INIS)

    Savelkoul, T.J.F.

    1984-01-01

    The author investigated the uptake and localization of 99m-technetium-methylene-diphosphonate (99m-Tc-MDP) in bone, to develop a sensitive mean for the detection of early osseous disease. In an electrolysis procedure without the presence of contaminating reductants a 99m-Tc-MDP complex is formed with clear bone-seeking properties. The scans performed in experimental animals are comparable in quality with 99m-Tc(Sn)-MDP scans. The uptake of 99m-Tc-MDP is faster and higher than the uptake of reduced hydrolyzed 99m-Tc. Uptake of 99m-Tc(Sn)-MDP in bone can only take place after decomposition of the complex. As 99m-Tc-MDP is taken up as a unit, this may be a better agent to evaluate the osteoblastic activity in the skeleton. (Auth./R.B.)

  3. Labeling of thymine with 99m technetium: a suggestion of a chemical model

    International Nuclear Information System (INIS)

    Gutfilen, Bianca; Silva, Claudia Ribeiro da; Bernardo Filho, Mario; Ribeiro, Barbara Luzia Almeida; Mattos, Maura Ferreira

    1996-01-01

    Successful targeting of diagnose but also to stage cancer. It has been shown that certain tumor cells are permeable to low level of exogenous adenosine-diphosphate and adenosine-triphosphate nucleotides, that are incorporated into intracellular pools. We present the labeling of a nucleotide precursor, a base, thymine technetium-99m ( 99m Tc). (author)

  4. Labeling of Tannic Acid with Technetium-99m for Diagnosis of Stomach Ulcer

    OpenAIRE

    Ibrahim, I. T.; El-Tawoosy, M.; Talaat, H. M.

    2011-01-01

    Tannic acid is a polyphenolic compound that could be labeled with technetium-99m. To produce about 90% yield of  99mTc-tannic acid in acidic media (pH), the conditions required were 150  g tin chloride, 30 min reaction time, and 200  g of the substrate. 99mTc-tannic was stable for 6 h. Oral biodistribution of 99mTc-tannic showed that it concentrated in the stomach ulcer to reach about 50% of the total injected dose at 1 h after orall administration. This concentration of 99mTc-tannic in s...

  5. Positive thyroid cancer scintigraphy using technetium-99m methoxyisobutylisonitrile

    International Nuclear Information System (INIS)

    Nemec, J.; Nyvltova, O.; Blazek, T.; Vlcek, P.; Racek, P.; Novak, Z.; Preiningerova, M.; Hubackova, M.; Krizova, M.; Zimak, J.; Bilek, R.

    1996-01-01

    The aim of the study was to evaluate the possibility of detecting thyroid cancer recurrences without the need for withdrawal of thyroid suppressive treatment. Upper-body or whole-body scintigraphy was performed in a group of 200 patients evaluated for differentiated thyroid cancers in 1993 and 1994 using technetium-99m sestamibi. Scans were performed 20-30 min following i.v. administration of 500 MBq of 99m Tc-methoxyisobutylisonitrile (MIBI). Bone and lung metastases were detected with very high sensitivity and specificity, with a very high predictive value of negative results and a somewhat lower predictive value of positive results. The sensitivity and specificity of findings in the neck were lower but the predictive value of negative results was high. Whole-body scans with 99m Tc-MIBI are a useful tool in the follow-up of patients with differentiated thyroid cancer, for the detection of distant metastatic lesions. (orig.)

  6. Detection of unstable angina by /sup 99m/technetium pyrophosphate myocardial scintigraphy

    International Nuclear Information System (INIS)

    Abdulla, A.M.; Canedo, M.I.; Cortez, B.C.; McGinnis, K.D.; Wilhelm, S.K.

    1976-01-01

    /sup 99m/Technetium stannous pyrophosphate has been shown to accumulate in acutely infarcted myocardium. To determine if the isotope is also taken up by severely ischemic, but not necrotic myocardium, we performed myocardial scintigraphic studies in 17 patients with chest pains. Seven of the patients satisfied conventional clinical, electrocardiographic, and laboratory criteria for the diagnosis of unstable angina and showed no electrocardiographic or enzymatic evidence of myocardial necrosis. Five of these seven patients with unstable angina demonstrated abnormal localized patterns, and one showed a borderline picture. Myocardial scintiscans were normal in all of a control group of ten patients with stable angina. Thus, scanning with /sup 99m/technetium stannous pyrophosphate is shown to be of value in the objective demonstration of myocardial abnormality in unstable angina

  7. Clinical usefulness of scintigraphy with sup 99m Technetium phosphates in rhabdomyolysis

    Energy Technology Data Exchange (ETDEWEB)

    Aizawa, Nobuyuki; Hara, Yoshikuni (Shonan Kamakura Hospital, Kanagawa (Japan)); Suzuki, Yutaka; Akashi, Tsunehiro; Kamei, Tetsumasa; Uchiyama, Fujio; Mitsui, Tamito; Yamazaki, Yuki

    1990-08-01

    We performed bone scans with {sup 99m}Technetium phosphates in 15 cases of clinically suspected rhabdomyolysis admitted to Chigasaki Tokushukai Hospital. Whole body scans were performed within 5 days from the onset of illness or admission. Accumulation of the radioactivity in the skeletal muscle was revealed in 13 of the 15 cases and the involved muscle groups were visualized vividly. Etiologies of rhabdomyolysis were diverse, ranging from malignant syndrome to sepsis. Myocardial concentration was absent in all of the cases. Renal concentration of the isotope was seen in cases where the degree of rhabdomyolysis was higher and renal impairment was present. We conclude that {sup 99m}Technetium phosphate bone scan is useful in clinically suspected rhabdomyolysis as a diagnostic test and as a test to localize and quantitate the muscular involvement. (author).

  8. Extraosseous uptake of /sup 99/sup(m)technetium methylene diphosphonate. Neuroblastoma or radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Sty, J R; Kun, L; Casper, J; Babbitt, D P

    1980-01-01

    A child with a ganglioneuroblastoma and tumor uptake of /sup 99/sup(m)technetium methylene diphosphate (/sup 99/sup(m)Tc-MDP) is presented. After surgical removal of an encapsulated tumor and radiation therapy, an interval bone scan demonstrated the same presurgical abnormality. Awareness of abnormal uptake of /sup 99/sup(m)Tc-MDP in irradiated renal tissue prevents interpreting radiation nephritis as recurrent tumor.

  9. Clinical studies of alveolar-capillary permeability using technetium-99m DTPA aerosol

    International Nuclear Information System (INIS)

    Sundram, F.X.

    1995-01-01

    Soluble radioaerosols such as technetium-99m diethylene triamine pentacetate (DTPA) permit simple quantitative studies of alveolar-capillary permeability to be performed, since the submicronic aerosols are deposited mainly at the lung periphery and are cleared across the alveolar-capillary membrane. Regional alterations in permeability can also be noted using this radionuclide technique. We have measured the pulmonary epithelial permeability in normal subjects and the alteration in smokers, glue-sniffers, patients with inhalation burns, chronic obstructive pulmonary disease (COPD) and patients with lung metastases from thyroid cancer treated with radioiodine 131 I. In the normal volunteers, the time taken for 50% of inhaled 99m Tc DTPA to be cleared from the lungs (T1/2) was 66 minutes±1 sd of 12 mins. The smokers had a mean T1/2 of 20 mins±1 sd 4 min. In the hard-core glue-sniffing group, the majority were smokers who had stopped smoking and glue-sniffing for periods varying from 1 day to 42 days, and it was possible to note the changes in clearance times against period of abstinence. In the patients with inhalation burns, there was change in lung clearance arising from pulmonary epithelial damage; these patients showed increased rate of clearance (short T1/2) with mean T1/2 of 36 min±1 sd of 11 mins, while the retention images revealed regional lung damage in moderately severe inhalation burns. Twenty-four patients with COPD had inhalation scans done with Tc-99m tin colloid radioaerosol, and these images were compared with the perfusion lung scans done with 99m Tc macroaggregated albumin (MAA); in general the perfusion images matched the defects noted in the inhalation scans. The 99m Tc DTPA clearance rate in these patients was normal i.e. T1/2=78±14 mins. In the thyroid cancer patients with lung metastases, who had high doses of radioiodine treatment, the T1/2 values were normal or prolonged slightly, mean T1/2=76 min±23. (author)

  10. In Vitro Evaluation of Tc-99m Radiopharmaceuticals for Gastric Emptying Studies

    Directory of Open Access Journals (Sweden)

    Türkan Ertay

    2014-02-01

    Full Text Available Objective: Gastrointestinal motility and functional motility disorders causing either delayed or accelerated gastric emptying (GE may result in similar symptoms including nausea, vomiting, early satiety, fullness, bloating, and abdominal discomfort or pain. Hence, it is important to evaluate patients for both rapid and delayed GE in the same test. The gold standard technique to measure GE is scintigraphy by radiolabeled test meals. The aim of this study was to test alternative Tc-99m agents to label eggs as the solid meal and compare to Tc-99m sulfur colloid (SC for gastric emptying studies. Methods: In search of alternative agents for gastric emptying studies, we mixed and fried eggs with four different particulate compounds (Tc-99m labeled SC, tin colloid, nanocolloid and MAA, as well as with free pertechnetate and Tc-99m DTPA. We then measured the stability of these compounds in simulated gastric juice. Results: Our experiments demonstrated that in addition to Tc-99m sulfur colloid;Tc-99m MAA, Tc-99m nanocolloid and Tc-99m tin colloid also appear to make stable complexes with eggs in acidic environment. Conclusion: Therefore, these agents may be used for gastric emptying studies which could be more practical in routine conditions.

  11. Rapid preparation method for technetium-99m bicisate

    Energy Technology Data Exchange (ETDEWEB)

    Hung, J.C. [Nuclear Medicine, Department of Diagnostic Radiology, Mayo Clinic, Rochester, Minnesota (United States); Chowdhury, S. [Nuclear Medicine, Department of Diagnostic Radiology, Mayo Clinic, Rochester, Minnesota (United States); Redfern, M.G. [Nuclear Medicine, Department of Diagnostic Radiology, Mayo Clinic, Rochester, Minnesota (United States); Mahoney, D.W. [Section of Biostatistics, Department of Health Sciences Research, Mayo Clinic, Rochester, Minnesota (United States)

    1997-06-10

    The method currently recommended for the preparation of technetium-99m bicisate ({sup 99m}Tc-bicisate) requires a lengthy 30-min incubation at room temperature. The purpose of this study was to evaluate an alternative method to shorten the preparation time. {sup 99m}Tc-bicisate was prepared with 3.7 GBq (100 mCi) {sup 99m}Tc according to the manufacturer`s instructions, except for the final incubation step, which was replaced with the microwave heating procedure. A standard thin-layer chromatography (TLC) method (i.e., Baker-Flex silica gel IB-F TLC plate with ethyl acetate as mobile phase) was used for the determination of the radiochemical purity (RCP) of {sup 99m}Tc-bicisate. Our evaluation with different microwave heating processes (300 W with different heating times) demonstrated that as the microwave heating temperature was increased (i.e., 44 -71 C), an increased percentage of samples reached 95% within 5 min post preparation (n=58). The highest RCP value (i.e., 97.4%{+-}0.5%, n=10) could be obtained immediately after an 8-s microwave heating time at 300 W (microwave temperature at 69 C), and an average RCP value of 96.4%{+-}1.3% (n=90) was maintained throughout the 24-h evaluation period. However, the trend seemed to reverse at higher microwave temperatures (i.e., 76 -90 C), which reconfirmed our initial findings that overheating had no benefit for the preparation of {sup 99m}Tc-bicisate. To ensure that temperature was the only determining factor, a hot water incubator set at 69 C was used (n=6). Similar RCP results were achieved. In conclusion, the use of a microwave oven at a low heat cycle provides a rapid and efficient way to prepare {sup 99m}Tc-bicisate. (orig.). With 3 figs., 1 tab.

  12. Technetium-99m-labeled annexin V imaging for detecting prosthetic joint infection in a rabbit model.

    Science.gov (United States)

    Tang, Cheng; Wang, Feng; Hou, Yanjie; Lu, Shanshan; Tian, Wei; Xu, Yan; Jin, Chengzhe; Wang, Liming

    2015-05-01

    Accurate and timely diagnosis of prosthetic joint infection is essential to initiate early treatment and achieve a favorable outcome. In this study, we used a rabbit model to assess the feasibility of technetium-99m-labeled annexin V for detecting prosthetic joint infection. Right knee arthroplasty was performed on 24 New Zealand rabbits. After surgery, methicillin-susceptible Staphylococcus aureus was intra-articularly injected to create a model of prosthetic joint infection (the infected group, n = 12). Rabbits in the control group were injected with sterile saline (n = 12). Seven and 21 days after surgery, technetium-99m-labeled annexin V imaging was performed in 6 rabbits of each group. Images were acquired 1 and 4 hours after injection of technetium-99m-labeled annexin V (150 MBq). The operated-to-normal-knee activity ratios were calculated for quantitative analysis. Seven days after surgery, increased technetium-99m-labeled annexin V uptake was observed in all cases. However, at 21 days a notable decrease was found in the control group, but not in the infected group. The operated-to-normal-knee activity ratios of the infected group were 1.84 ± 0.29 in the early phase and 2.19 ± 0.34 in the delay phase, both of which were significantly higher than those of the control group (P = 0.03 and P = 0.02). The receiver operator characteristic curve analysis showed that the operated-to-normal-knee activity ratios of the delay phase at 21 days was the best indicator, with an accuracy of 80%. In conclusion, technetium-99m-labeled annexin V imaging could effectively distinguish an infected prosthetic joint from an uninfected prosthetic joint in a rabbit model.

  13. Studies on quality control of technetium-99m labelling kits

    International Nuclear Information System (INIS)

    Kim, Jae Rok; Park, Kyung Bae; Awh, Ok Doo

    1987-12-01

    Various experiments for the quality control of Tc-99m labelled radiopharmaceuticals such as Tc-99m-phytate, Tc-99m-MDP, Tc-99m-Tin Colloid, Tc-99m-DISIDA, Tc-99m-DTPA,Tc-99m-DMSA, Tc-99m-Gulcoheptonate, TC-99m-Pyrophosphate, Tc-99m-HSA, and Tc-99m-HAM were carried out. Labelling yield and radiochemical purity of each of the instant labelling kit of KAERI made were determined by means of radiochromatography. Biodistribution in mice and whole body or specific organ imagings of rabbits were also carried out and discussed the relationship between the data of biodistributions and radiochemical purities. Labelling yeilds were above 98% for almost all of the labelling kits. The radio-pharmaceuticals were accumulated at each target organ with moderate specifities. In case of radiochemical purity of above 98%, the biodistribution and gamma imagings were also better. The kits of MDP and DISIDA were stable at least for four moths while the other kits at least eight months. (Author)

  14. Cold hematoma visualized by technetium-99m labeled red blood cells

    International Nuclear Information System (INIS)

    Beanblossom, M.

    1986-01-01

    A 64-yr-old male was admitted to the hospital with severe abdominal pain associated with vomiting. Upon examination, the patients Hgb was 7.8 with a WBC count of 13.3 band cells of 7 and a recticulocyte count of 3.4, no evidence of gastrointestinal bleeding. The patient's prior history revealed involvement in an automobile accident ∼ 10 days prior to this admission. At that time, he suffered multiple contusions and abrasions with a fracture to his left clavicle. Apparently there were no episodes of abdominal pain or vomiting prior to the onset of illness perceived on the day of admission. A liver/spleen scan was done. Four millicuries of /sup 99m/Tc-sulfur colloid were intravenously injected using a bolus injection technique while obtaining multiple dynamic images. The flow study was unremarkable, demonstrating no abnormalities to the great vessels and good perfusion to both organs. Static images of the liver and spleen revealed a straightening or flatness to the lateral border of the spleen with a small diminished area of tracer sulfur colloid localization at the posterolateral aspect of that organ. This finding raised the suspicion that a small subcapsular hematoma had developed at the mid-posterolateral aspect of the spleen. Twenty-four hours after hospital admission, 4 units of packed RBCs were transfused into the patient. Although there was at this time still no evidence of abnormal bleeding, it was felt that because of the strong symptomatic correlation for internal bleeding, a radionuclide bleeding site study should be ordered and immediately performed

  15. Periarticular uptake of /sup 99m/technetium diphosphonate in psoriatics. Correlation with cutaneous activity

    International Nuclear Information System (INIS)

    Namey, T.C.; Rosenthall, L.

    1976-01-01

    The periarticular uptake of /sup 99m/technetium-labeled diphosphonate (/sup 99m/TcDP) was compared in 12 patients hospitalized for psoriasis and in 12 hospitalized for other dermatoses not associated with arthropathy. The 12 patients with psoriasis had recent onset disease of less than 5 years duration; neither group had historical or clinical evidence of arthritis. All psoriatics had markedly abnormal scans with symmetrically increased periarticular uptake about the imaged joints. None of the controls had similar findings. In 4 patients scanned with /sup 99m/technetium-pertechnetate within 24 hours of their /sup 99m/TcDP scan, no evidence of inflammatory synovitis was found. Three of these patients were serially imaged with /sup 99m/TcDP at intervals of 2 weeks to 3 months after their initial study, when obvious clinical improvement in their psoriasis was apparent. Improvement in the radionuclide joint images was demonstrated in some of the patients, but none reverted to normal during the study period. In light of recent evidence for the preferential binding of /sup 99m/TcDP to immature collagen, it is suggested that psoriasis may represent a generalized, but uncharacterized, collagen disorder present in bone as well as skin, linking the cutaneous disease with the potential for arthropathy

  16. Clinical comparison of cardiac blood pool visualization with technetium-99m red blood cells labeled in vivo and with technetium-99m human serum albumin

    International Nuclear Information System (INIS)

    Thrall, J.H.; Freitas, J.E.; Swanson, D.; Rogers, W.L.; Clare, J.M.; Brown, M.L.; Pitt, B.

    1978-01-01

    Technetium-99m red blood cells (Tc-RBC) labeled by an in vivo technique were compared with two preparations of Tc-99m human serum albumin (HSA) for cardiac blood-pool imaging. Relative distribution of the tracers was analyzed on end-diastolic frames of gated blood-pool studies and on whole-body (head to mid-thigh) anterior pinhole images. The Tc-RBC demonstrated greater relative percentage localization in the cardiac blood pool, higher target-to-background ratios in the left ventricle, and less liver concentration. For cardiac blood-pool imaging, Tc-RBC labeled by the in vivo approach appears to be superior to the two Tc-HSA preparations studied

  17. Preparation of 99mTc- Tin colloid: a freeze-dried kit for liver imaging

    International Nuclear Information System (INIS)

    Hamada, E.S.; Muramoto, E.; Barbosa, M.R.F. de; Colturato, M.T.; Herrerias, R.

    1988-07-01

    99m Tc-tin-colloid was formulated as a useful agent for liver imaging. The radiochemical purity and stability of the labeled colloid were determined by paper chromatography and 85% methanol solvent, the labelling efficiency was > 95%. The comparative studies of the biological distribution of 99m Tc-tin-colloid and 99 Tc-Sulphur-colloid were made with Wistar rats. The results of organ distribution were similar in both products; > 90% liver uptake. (author) [pt

  18. Labeling of thymine with {sup 99m} technetium: a suggestion of a chemical model

    Energy Technology Data Exchange (ETDEWEB)

    Gutfilen, Bianca; Silva, Claudia Ribeiro da; Bernardo Filho, Mario [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Inst. de Biologia. Dept. de Biofisica e Biometria; Ribeiro, Barbara Luzia Almeida [Instituto Nacional do Cancer, Rio de Janeiro, RJ (Brazil). Centro de Pesquisa Basica; Mattos, Maura Ferreira [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Inst. de Quimica

    1996-03-01

    Successful targeting of diagnose but also to stage cancer. It has been shown that certain tumor cells are permeable to low level of exogenous adenosine-diphosphate and adenosine-triphosphate nucleotides, that are incorporated into intracellular pools. We present the labeling of a nucleotide precursor, a base, thymine technetium-99m ({sup 99m} Tc). (author)

  19. Acetylsalicylic acid and labeling of blood constituents with technetium-99m

    Energy Technology Data Exchange (ETDEWEB)

    Fonseca, Adenilson de Souza da [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Dept. de Farmacologia e Psicobiologia; Frydman, Jacques Natan Grinapel; Rocha, Vanessa Camara da; Bernardo-Filho, Mario [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Inst. de Biologia Roberto Alcantara Gomes. Dept. de Biofisica e Biometria

    2005-10-15

    Acetylsalicylic acid is the drug most used an anti-inflammatory agent and for secondary prevention of thrombotic phenomenon. Drugs can modify the labeling of blood constituents with technetium-99m (99m Tc). The aim of this work was to evaluate the effect of in vitro or in vivo assays with acetylsalicylic acid on the labeling of the blood constituents with 99m Tc. In vitro assay was performed with samples of whole blood from Wistar rats incubated with acetylsalicylic acid (1.0 mg/ml) for one hour before the 99m Tc-labeling process. For in vivo assay, Wistar rats were treated with acetylsalicylic acid (1.5 mg/kg) during one hour, and the whole blood was withdrawn for the 99m Tc-labeling process. Saline was used in control groups. Data showed that the fixation of 99m Tc to the blood constituents was not significantly (p>0.05) modified in in vitro and in vivo assays with acetylsalicylic acid, at least not when the experiments were carried out with the doses normally used in human beings. (author)

  20. Diagnostic usefulness of technetium-99m (V) DMSA scintigraphy in cases of soft tissue tumors; In comparison with that of Ga-67 citrate scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Hisataka; Kotoura, Yoshihiko; Hanbara, Harumi; Hosono, Makoto; Yamamuro, Takao; Konishi, Junji (Kyoto Univ. (Japan). Faculty of Medicine)

    1994-05-01

    Technetium-99m (V) DMSA scintigraphy was performed in 76 patients with pathologically confirmed soft tissue diseases. In 56 patients, gallium-67 citrate scintigraphy was performed within two weeks after technetium-99m (V) DMSA scintigraphy. Significant uptake of technetium-99m (V) DMSA was found in all cases of sarcoma, metastatic carcinoma, progressive benignancy (extra-abdominal desmoid etc.) and granulomatous lesions, but was not found in cases of benign, solid tumors in the soft tissue (leiomyoma, neurinoma, lipoma etc.). In conclusion, it is not necessary to treat patients with soft tissue tumors in which technetium-99m (V) DMSA did not accumulate. Therefore, it can be stated that technetium-99m (V) DMSA scintigraphy is useful for the screening of malignant tumors. (author).

  1. Risk analysis applied to the production of generators of Molybdenum-99/Technetium-99m

    International Nuclear Information System (INIS)

    Rodriguez, Daniel; Torres, Antonio; Henriquez, Jorge R.; Soria, Miguel A.; Ayra, Fernando E.

    2017-01-01

    Radionuclide Technetium-99m is the most used today, so that their production is vital to the branches of health and the economy of any country. Cuba currently producing generators for obtaining this radionuclide, and it is produce at the Center of Isotopes. Risk assessments of radiological hazard installations are a regulatory requirement in Cuba. Although there are several qualitative or quantitative methods to perform these studies, the existence of basis risk starting and analysis codes and simplicity of use has been privileged the risk matrix as a preferred semi-quantitative method. The investigation presents the application, for the first time, of this method on a complex installation with radiological hazard in Cuba. Using the SECURE - MR Ver. 2.0 code detailed risk analysis of the practice carried out, resulting in three accidental sequences with high-risk level and determining the importance of reducers and barriers related with human factors associated to sufficiency and personnel training. Among the derived applications are reported the novelties analysis capabilities and possibilities of risk monitoring. The risk model developed for the production process of generators of Molybdenum-99/Technetium-99m joined with capabilities review, analysis and documentation provided by the tool, allow obtaining a completely and coherent document with the model, which constitutes a valuable basis for understanding the safety of the installation knowledge. (author)

  2. Risk analysis applied to the production of generators of Molybdenum-99/Technetium-99m

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, Daniel; Torres, Antonio; Henriquez, Jorge R.; Soria, Miguel A.; Ayra, Fernando E., E-mail: danivd1188@gmail.com, E-mail: rjorge@ufpe.br, E-mail: masguevara@centis.edu.cu, E-mail: feayra@centis.cu [Universidade Federal de Pernambuco (DEMEC/UFPE), Recife, PE (Brazil). Departamento de Engenharia Mecanica; Departamento de Ingenieria Nuclear, Instituto Superior de Tecnologias y Ciencias Aplicadas (DIN/InSTEC), La Habana (Cuba); Departamento de Proteccion Radiologica, Centro de Isotopos (DPR/CENTIS), La Habana (Cuba)

    2017-11-01

    Radionuclide Technetium-99m is the most used today, so that their production is vital to the branches of health and the economy of any country. Cuba currently producing generators for obtaining this radionuclide, and it is produce at the Center of Isotopes. Risk assessments of radiological hazard installations are a regulatory requirement in Cuba. Although there are several qualitative or quantitative methods to perform these studies, the existence of basis risk starting and analysis codes and simplicity of use has been privileged the risk matrix as a preferred semi-quantitative method. The investigation presents the application, for the first time, of this method on a complex installation with radiological hazard in Cuba. Using the SECURE - MR Ver. 2.0 code detailed risk analysis of the practice carried out, resulting in three accidental sequences with high-risk level and determining the importance of reducers and barriers related with human factors associated to sufficiency and personnel training. Among the derived applications are reported the novelties analysis capabilities and possibilities of risk monitoring. The risk model developed for the production process of generators of Molybdenum-99/Technetium-99m joined with capabilities review, analysis and documentation provided by the tool, allow obtaining a completely and coherent document with the model, which constitutes a valuable basis for understanding the safety of the installation knowledge. (author)

  3. Biodistribution of 99m technetium labeled creatinine in healthy rats

    International Nuclear Information System (INIS)

    Yilmaz, O.; Soylu, A.; Kavukcu, S.; Lambrecht, F. Yurt; Durkan, K.

    2007-01-01

    The distribution of creatinine, one of the toxic guanidine compounds, in various tissues has not been studied in detail by using radiolabeled creatinine. Our objective was to investigate the biodistribution of creatinine labeled with 99m technetium ( 99m Tc) by the stannous (II) chloride method in healthy male Wistar rats. Quality controls were carried out by radio thin layer chromatography, high-performance liquid chromatography, and paper electrophoresis. The labeling yield was 85 ± 2% under optimum conditions (pH 7 and 100 μg stannous chloride). Rats (N 12) were injected intravenously with 99m Tc creatinine and their blood and visceral organs were evaluated for 99m Tc-creatinine uptake as percent of the injected dose per gram wet weight of each tissue (%ID/g). The lowest amount of uptake was detected in the brain and testis. When the rate of uptake was evaluated, only the kidney showed increasing rates of uptake of 99m Tc-creatinine throughout the study. Kidneys showed the highest amount of uptake throughout the study (P < 0.001 compared to all other organs), followed by liver, spleen and lung tissue. (author)

  4. Radiation hazards from horses undergoing scintigraphy using technetium -{sup 99m}

    Energy Technology Data Exchange (ETDEWEB)

    Whitelock, R.G. [Royal Veterinary College, Hatfield (United Kingdom)

    1997-01-01

    This paper quantifies the extent of the radiation hazard to personnel from horses undergoing scintigraphy using technetium{sup 99m} methylene diphosphonate ({sup 99m}Tc{sup m}-MDP). From the data produced it is possible to derive safe working protocols which are comfortably within the legislated limits for whole body doses as set out in the Ionising Radiations Regulations 1985. Measurements were made of the surface and environmental activities which result from individuals undergoing scintigraphic evaluation and also from urine contaminated bedding. The use of both high and low activities in the assessment of the radiation hazard to personnel and owners is considered. (author).

  5. Exposure to fingers while handling a solvent extraction-type technetium-99m generator

    International Nuclear Information System (INIS)

    Kini, K.S.; Venkateswaran, T.V.

    1985-01-01

    Technetium-99m-labeled compounds are routinely used for various diagnostic procedures in nuclear medicine. In India, most of the nuclear medicine centers use /sup 99m/Tc obtained from a solvent extraction-type generator. As a result of the long procedure involved in the separation of /sup 99m/Tc from /sup 99m/Mo in this type of generator compared to the elution of /sup 99m/Tc from a column-type generator, like likelihood of exposure to fingers of technicians is high. The measurement of radiation exposure was done on 16 workers at seven major nuclear medicine centers in India. With the existing work load, the exposures to the fingers were found to be within the permissible limits

  6. Technetium 99mTc Pertechnetate Brain Scanning

    International Nuclear Information System (INIS)

    Rhee, Sang Min; Park, Jin Yung; Lee, Ahn Ki; Chung, Choo Il; Hong, Chang Gi; Rhee, Chong Heon; Koh, Chang Soon

    1968-01-01

    Technetium 99 mTc pertechnetate brain scanning were performed in 3 cases of head injury (2 chronic subdural hematomas and 1 acute epidural hematoma), 2 cases of brain abscess and 1 case of intracerebral hematoma associated with arteriovenous anomaly. In all the cases brain scintigrams showed 'hot areas.' Literatures on radioisotope scanning of intracranial lesions were briefly reviewed. With the improvement of radioisotope scanner and development of new radiopharmaceuticals brain scanning became a safe and useful screening test for diagnosis of intracranial lesions. Brain scanning can be easily performed even to a moribund patient without any discomfort and risk to the patient which are associated with cerebral angiography or pneumoencephalography. Brain scanning has been useful in diagnosis of brain tumor, brain abscess, subdural hematoma, and cerebral vascular diseases. In 80 to 90% of brain tumors positive scintigrams can be expected. Early studies were done with 203 Hg-Neohydrin or 131 I-serum albumin. With these agents, however, patients receive rather much radiation to the whole body and kidneys. In 1965 Harper introduced 99 mTc to reduce radiation dose to the patient and improve statistical variation in isotope scanning.

  7. Protective Effect of Slforafin on the Non-Enzymatic Antioxidants and Chromosomal Aberrations When Injected with Tc "9"9"m Tin colloid in Mice

    International Nuclear Information System (INIS)

    Alwan, I.F.; Abd-Karim, H.M.; Ahmood, A.M.; Mohamad, H.A.

    2015-01-01

    Study aims to evaluated the preventive effect of (Slforafin ) compound extracted from Broccoli plant to effect on Technetium"9"9"m irradiated isotope user to labeled Tin colloid and used in prevent several Tin colloid changes , antioxidant Non-Enzymatic ( vitamin A,E,C ) and some of the basic elements in serum , such as (Zn, Mn, Se, Mg and Cu) and (Chromosomal Aberrations ) in the bone marrow genes of laboratory animals .Slforafin compound was analyzed by High-performance liquid chromatography technique HPLC. Treated the laboratory animals daily with, concentration (200 mg / kg) of Slforafin Broccoli extract material through mouth for one week ,then were injected with (500 μci / 0.1 ml) doses of preparation Tc"9"9"m Tin colloidal.The results indicated that there are significant differences (p< 0.05) at the deviation level of Non- enzymatic changes and chromosomal genes and some of the basic elements in serum of the Non –treated laboratory animals with Slforafin compound compared with the group of animals treated with (Slforafin) and injected with the same radiation dose compared with the control laboratory animal groups .

  8. Technetium-99m sestamibi: an indicator of breast cancer invasiveness

    Energy Technology Data Exchange (ETDEWEB)

    Scopinaro, F. (Section of Nuclear Medicine, Dept. of Experimental Medicine, Univ. ' La Sapienza' , Rome (Italy)); Schillaci, O. (Section of Nuclear Medicine, Dept. of Experimental Medicine, Univ. ' La Sapienza' , Rome (Italy)); Scarpini, M. (1st Inst. of Surgery, Univ. ' La Sapienza' , Rome (Italy)); Mingazzini, P.L. (1st Inst. of Surgery, Univ. ' La Sapienza' , Rome (Italy)); Di Macio, L. (Section of Nuclear Medicine, Dept. of Experimental Medicine, Univ. ' La Sapienza' , Rome (Italy)); Banci, M. (Section of Nuclear Medicine, Dept. of Experimental Medicine, Univ. ' La Sapienza' , Rome (Italy)); Danieli, R. (Section of Nuclear Medicine, Dept. of Experimental Medicine, Univ. ' La Sapienza' , Rome (Italy)); Zerilli, M. (1st Inst. of Surgery, Univ. ' La Sapienza' , Rome (Italy)); Limiti, M.R. (1st Inst. of Surgery, Univ. ' La Sapienza' , Rome (Italy)); Centi Colella, A. (Section of Nuclear Medicine, Dept. of Experimental Medicine, Univ. ' La Sapienza' , Rome (Italy))

    1994-09-01

    As recently shown, angiogenesis is the most reliable marker of breast cancer invasiveness. Unfortunately it must be assessed by immunohistochemistry on tissue specimens. We have used technetium-99m sestamibi, a marker of regional blood flow in other organs that often but not always images breast cancer, to assess the invasiveness of this tumour. Nineteen patients, ten with nodal metastases and nine without any metastases, were studied with [sup 99m]Tc-sestamibi scintigraphy before operation. Angiogenesis was quantitatively assessed by immunohistochemical staining of endothelia for factor VIII. All the node-positive (N+) patients at surgical revesion showed a positive [sup 99m]Tc-sestamibi scan of the primary tumour and all the N-patients were negative. Nine out of ten N+ and sestamibi-positive tumours showed more than 135 microvessels/mm[sup 2] and one showed 99 microvessels/mm[sup 2]; by contrast there were 71.6[+-]12.1 microvessels/mm[sup 2] in the nine N- and sestamibi-negative tumours. Our study suggests that [sup 99m]Tc-sestamibi is a marker of breast cancer invasiveness: its uptake is related to angiogenesis and, possibly, to oxidative metabolism of the tumour. (orig.)

  9. How good is technetium-99m mercaptoacetyltriglycine indirect cystography?

    International Nuclear Information System (INIS)

    Sadeleer, C. de; Boe, V. de; Keuppens, F.; Desprechins, B.; Verboven, M.; Piepsz, A.

    1994-01-01

    The aim of the present study was to estimate the sensitivity of indirect radionuclide cystography (IRC) performed with technetium-99m mercaptoacetyltriglycine (MAG3), in comparison with the micturition cystourethrography (MCUG) and direct radionuclide cystography (DRC), for the diagnosis of vesicoureteric reflux. Two groups of patients were selected: group I comprised 40 children who underwent IRC during the acute phase of urinary tract infection and an MCUG 6 weeks later; group II comprised 42 (other) children with known reflux, who underwent IRC and DRC during follow-up. Taking as the reference the total number of refluxing kidneys detected by means of any cystographic technique, 99m Tc-MAG3 ICR missed two-thirds of the refluxing kidneys. Most of the small refluxes were missed, but so too were 50% of the major refluxes. Taking as the reference 99m Tc dimercaptosuccinic acid (DMSA) scintigraphy, MCUG detected 91% of the patients with DMSA abnormalities on at least one kidney, DRC detected 95%, and IRC detected 46% and 43% respectively, in groups I and II. The use of 99m Tc-MAG3 IRC as the sole technique for the detection of vesicoureteric reflux gives rise to an unacceptable number of false-negative results. (orig.)

  10. Environmental behavior of technetium-99

    International Nuclear Information System (INIS)

    Turcotte, M.D.S.

    1982-12-01

    This report presents a review of the literature on technetium-99. The chemical and physical properties of some technetium compounds are considered, and a discussion of possible source terms is included. Literature on the environmental behavior of technetium is presented, including its behavior in the bodies of animals and humans. The primary sources of Tc-99 in the environment are fallout from atomic detonations and releases from nuclear fuel reprocessing plants. The environmental behavior of technetium-99 has been studied predominantly with respect to movement in soil and accumulation in plants. There is a surprising scarcity of data on behavior of Tc-99 in the atmosphere and in aquatic systems. Additional work needs to be conducted in these two areas to determine behavior and to acquire baseline concentration data. Much of the soil work has produced contradictory results. In-depth studies of holdup mechanisms for Tc-99 in both geological repositories and soil need to be conducted. Since plants represent a potential bioaccumulation of Tc-99, plant uptake studies of Tc-99 under field conditions also need to be done

  11. Technetium-99m-labeled N-(2,6-dimethylphenylcarbamoylmethyl) iminodiacetic acid (/sup 99m/Tc HIDA): a new radiopharmaceutical for hepatobiliary imaging studies

    International Nuclear Information System (INIS)

    Ryan, J.; Cooper, M.; Loberg, M.; Harvey, E.; Sikorski, S.

    1977-01-01

    An easily formulated, stable kit preparation of technetium-99m HIDA, suitable for use in humans, was developed and tested in mice and dogs. The tracer was cleared rapidly from the blood and excreted predominantly by the liver in both species. In dogs, the hepatobiliary clearance of Tc-99m HIDA was significantly greater than that of C-14 HIDA and Sn-113 HIDA. The LD 50 for HIDA in mice, 168 mg/kg, exceeded the average human dose by a factor of 1000 on a per-weight basis. Blood clearance curves for Tc-99m HIDA in 12 normal subjects were biexponential with half-times of 4.6 +- 1.0 min and 31.5 +- 7.0 min, and cumulative 90-min urine samples contained 14.2 +- 1.8% of the injected dose. Images in normal subjects and nonjaundiced patients showed rapid concentration of tracer by the liver and activity was present within the biliary system in 10 to 20 min. In jaundiced patients, the tracer blood clearance was delayed and urinary excretion increased, but intestinal activity, indicating biliary patency, was imaged in those patients without complete focal obstruction of the common duct. Technetium-99m HIDA is a nontoxic radiopharmaceutical useful for clinical evaluation of hepatobiliary disorders in humans

  12. Technetium-99m pertechnetate - a tracer for radiolabelling antibody for inflammation detection

    International Nuclear Information System (INIS)

    Shaharuddin Mohd; Wan Hamirul Bahrin Wan Kamal; Shahrin A Hamid; Ang Woan Tze; Rosnani Hashim

    1999-01-01

    The polyclonal antibody, Human Immunoglobulin G (HlgG) was reduced by using 2-mercaptoethanol with molar ratio of 1000:1 (i.e. mercaptoethanol:antibody). The reduction of the antibody, was carried out for 30 minutes at room temperature. The reduced antibody was purified by using Sephadex G-25 fine column. The antibody kit for the detection of inflammation was prepared aseptically in Class 1 Laminar Flow cabinet. The kit passed the sterility test. Upon reconstitution of the antibody kit with sodium pertechnetate-99m ( 99m Tc) solution, the labelling efficiency obtained was more than 95%. This preparation was stable up to 24-hour stored at room temperature. Gamma camera scans showed the accumulation of technetium-99m labelled antibody ( 99m Tc-HIgG) at the turpentine-induced inflammation of female Sprague-Dawley rats. This indicated the possibility of using 99m Tc-HIgG for inflammation detection. (author)

  13. Technetium /sup 99m/Tc macroaggregated albumin lung scans. Use in chronic childhood asthma

    International Nuclear Information System (INIS)

    Hyde, J.S.; Koch, D.F.; Isenberg, P.D.; Werner, P.

    1976-01-01

    Serial roentgenograms and technetium /sub 99m/Tc macroaggregated albumin lung scans were done simultaneously in 30 bronchodilator-dependent asthmatic children and young adults during both relative remission and attacks of status asthmaticus. When chest roentgenograms showed air trapping and increased peribronchial vascular markings associated with persistent perfusion defects, the children benefited from further laboratory studies and continuous comprehensive therapy. Serial scans provided information about underperfusion that was not discernible either by roentgenograms or by usual blood gas studies. Also, lung scans are easier to obtain in children with long-standing asthma than are detailed pulmonary tests. In our study, technetium /sup 99m/Tc macroaggregated albumin scans showed persistent regional perfusion defects in 20 children with chronic asthma during relative remission and exacerbations

  14. Dynamic biliary cholecystography with mebrofenin-Tc-99m in a patient with benign recurrent intrahepatic cholestasis

    International Nuclear Information System (INIS)

    Tadzher, I.S.; Grujovska, S.; Todorovski, G.; Arsova, S.

    1996-01-01

    A Caucasian boy with a 16-year history of benign recurrent intrahepatic cholestasis (BRIC) presented dissociation between normal hepatic extraction fraction of mebrofenin-Tc-99m (HEF over 90%) and that of intensive delayed liver 'washout' T 1/2 210 m (normal 20-25 m). This is the second case in Macedonia (population 2.3 million) showing the same pattern of bile dynamic with mebrofenin-Tc-99m: normal HEF, prolonged 'washout'. In Rotor's disease and Dubin-Johnson's syndrome HEF is depressed and 'washout' delayed, whereas in Gilbert's syndrome we found both parameters normal. In our patient the episodes of pruritus were intensive and prolonged, hyperbilirubinaemia 50-100 micromol/L. Gallbladder was hypovolemic, ejection fraction reduced (59%, normal with the employed method over 70%). Growth, body weight and bone age were subnormal. Technetium-sulfur-colloid scans showed enlarged liver, splenomegaly and reduced portal contribution to hepatic blood flow (65%, normal over 70%). (Author)

  15. Technetium-99m in nuclear medicine and radiation protection experience

    International Nuclear Information System (INIS)

    Ninkovic, M. M.; Raicevic, J. J.; Pavlovic, S.; Glisic, R.

    2002-01-01

    The one of the major contributors to personnel exposure whithin nuclear medicine laboratories is primarily now ubiquitous 99 Mo- 99m Tc generators. These generators, first available about more than forthy years ago, are now providing large quantities of 99m Tc radioactive source daily in the most laboratories, both for direct injection, as a per-technetate ion, and through the utilization of the kits for the preparation of dipherent radiopharmaceuticals. The safe and efficient utilization of technetium-99m in nuclear medicine, as other radionuclides, begin with the design, construction and operation of the 'Hot'Laboratory area, where radionuclide are stored and patient doses are prepared. Regardless of the specific physical configuration, suitable facilities need to be provided and good working practices established in order to get these principal objectives: (a) keep radiation exposure to personnel at ALARA levels; (b) prevent contamination of personnel; (c) prevent contamination of measuring instruments (including imaging devices such as gamma cameras and rectilinear scanners), and (d) prevent spread of contamination to places or persons outside the laboratory

  16. Efficient one-step direct labelling of recombinant antibodies with technetium-99m

    International Nuclear Information System (INIS)

    Liberatore, M.; Neri, D.; Neri, G.; Pini, A.; Lurilli, A.P.; Ponzo, F.; Spampinato, G.; Padula, F.; Pala, A.; Colella, A.C.

    1995-01-01

    High-affinity bacterially expressed antibody fragments can nowadays be cloned from established hybridomas or, more conveniently, isolated directly from antibody libraries displayed on filamentous phage. Such antibodies can be tagged with C-terminal peptide tags containing one cysteine residue, which represents a convenient functionalisation site for a number of applications, including technetium-99m labelling. Here we describe a simple one-step method for 99m Tc labelling of cysteine-tagged recombinant antibodies with more than 50% radionuclide incorporation. The labelled antibodies displayed full retention of immuoreactivity and good stability. (orig.)

  17. Efficient one-step direct labelling of recombinant antibodies with technetium-99m

    Energy Technology Data Exchange (ETDEWEB)

    Liberatore, M. [Dipartimento di Medicina Sperimentale, Sezione di Medicina Nucleare, Policlinico Umberto I, Universita di Roma `La Sapienza` (Italy); Neri, D. [Cambridge Centre for Protein Engineering - MRC Centre (United Kingdom); Neri, G. [Dipartimento di Biologia Molecolare, Universita di Siena (Italy); Pini, A. [Dipartimento di Biologia Molecolare, Universita di Siena (Italy); Lurilli, A.P. [Dipartimento di Medicina Sperimentale, Sezione di Medicina Nucleare, Policlinico Umberto I, Universita di Roma `La Sapienza` (Italy); Ponzo, F. [Dipartimento di Medicina Sperimentale, Sezione di Medicina Nucleare, Policlinico Umberto I, Universita di Roma `La Sapienza` (Italy); Spampinato, G. [Laboratorio di Biochimica degli Ormoni Sessuali, Il Instituto di Clinica Ostetrica e Ginecologica, Universita di Roma `La Sapienza` (Italy); Padula, F. [Laboratorio di Biochimica degli Ormoni Sessuali, Il Instituto di Clinica Ostetrica e Ginecologica, Universita di Roma `La Sapienza` (Italy); Pala, A. [Laboratorio di Biochimica degli Ormoni Sessuali, Il Instituto di Clinica Ostetrica e Ginecologica, Universita di Roma `La Sapienza` (Italy); Colella, A.C. [Dipartimento di Medicina Sperimentale, Sezione di Medicina Nucleare, Policlinico Umberto I, Universita di Roma `La Sapienza` (Italy)

    1995-11-01

    High-affinity bacterially expressed antibody fragments can nowadays be cloned from established hybridomas or, more conveniently, isolated directly from antibody libraries displayed on filamentous phage. Such antibodies can be tagged with C-terminal peptide tags containing one cysteine residue, which represents a convenient functionalisation site for a number of applications, including technetium-99m labelling. Here we describe a simple one-step method for {sup 99m}Tc labelling of cysteine-tagged recombinant antibodies with more than 50% radionuclide incorporation. The labelled antibodies displayed full retention of immuoreactivity and good stability. (orig.)

  18. Scintigraphic visualization of extrahepatic portal circulation in patients with portal hypertension using /sup 99m/Tc-tin-colloid and /sup 99m/Tc-HIDA

    Energy Technology Data Exchange (ETDEWEB)

    Al-Hussoni, M H; Jasim, M N; Shubbar, A H

    1985-01-01

    Rapid dynamic sequential scintigraphy of the abdomen with /sup 99m/Tc-tin-colloid and /sup 99m/Tc-HIDA has been used to evaluate two patients with portal hypertension. /sup 99m/Tc-tin-colloid was useful for visualization of diliated vessels in the abdomen. Radionuclide hepatobiliary imaging was useful in such cases in evaluation of the hepatobiliary system.

  19. Intra-arterial and intraportal infusion liver scintigraphy using 99mTc-labeled colloid

    International Nuclear Information System (INIS)

    Inoue, Yusuke; Ohtake, Tohru; Momose, Toshimitsu; Watanabe, Toshiaki; Kosaka, Noboru; Nishikawa, Jun-ichi; Sasaki, Yasuhito; Sawada, Toshio; Muto, Tetsuichiro

    1991-01-01

    Intra-arterial infusion liver scintigraphy was performed in 11 patients with primary or metastatic liver tumor. and intraportal infusion liver scintigraphy was performed in 6 patients for prophylaxis of liver metastasis from colorectal cancer. 99m Tc-Sn colloid or 99m Tc-phytate was administered through the catheter of which tip was placed in the portal vein or the hepatic artery, and then liver image was obtained. When 99m Tc-phytate was infused intra-arterially, significant amount of the infused tracer passed through the liver and we could not get sufficient information to assess the distribution of drug administered through the catheter. On the other hand, intraportal infusion liver scintigraphy using 99m Tc-Sn colloid or 99m Tc-phytate and intra-arterial infusion liver scintigraphy using 99m Tc-Sn colloid revealed heterogenity of liver uptake, tracer uptake in spleen, low uptake area corresponding to the liver tumor and high uptake area around it. The findings will be clinically useful, and these methods are thought to be helpful to confirm the satisfactory drug distribution. (author)

  20. Technetium-99m dextran: a promising new protein-losing enteropathy imaging agent

    International Nuclear Information System (INIS)

    Bhatnagar, A.; Singh, A.K.; Lahoti, D.; Singh, T.; Khanna, C.M.

    1996-01-01

    The purpose of this study was to evaluate technetium-99m dextran ( 99m Tc-Dx; molecular weight 81000) as a prospective protein-losing enteropathy (PLE) imaging agent. Twenty-two patients iwth diseases commonly associated with PLE and 12 healthy control subjects underwent intravenous 99m Tc-Dx scintigraphy. All of the 22 test patients showed significant radiotracer accumulation in the intestines within 3-4 h post injection. The focal, regional or generalised nature of the enteropathy and involvement of the large or small intestine could be identified in most cases. Four of the 12 apparently healthy subjects also showed minimal accumulation in the abdominal area occurring late in the study period. This could have been physiological, related to food habits or due to unsuspected intestinal worms. We attribute the high sensitivity of 99m Tc-Dx to its relatively fast blood (background) clearance. The radiotracer may have several other advantages over 99m Tc-labelled human serum albumin in imaging PLE. (orig.)

  1. Technetium-99m stannous pyrophosphate imaging of experimental infective endocarditis

    International Nuclear Information System (INIS)

    Riba, A.L.; Downs, J.; Thakur, M.L.; Gottschalk, A.; Andriole, V.T.; Zaret, B.L.

    1978-01-01

    Technetium-99m stannous pyrophosphate (/sup 99m/Tc-PYP) cardiac scintigraphy was performed in 15 rabbits with experimental Streptococcus sanguis aortic-valve infective endocarditis. The animals were imaged five to seven days after the administration of bacteria, and in each case abnormal accumulation of the tracer was visualized in the region of the aortic valve. Three types of cardiac scintigraphic patterns were demonstrated: focal, multifocal, and extensive, each correlating well with the anatomical extent of the lesion as defined by gross pathology. Tissue distribution studies demonstrated a 30 +- 5.3 (mean +- SEM) fold excess of radionuclide uptake in the infective endocarditis lesion compared with that of normal myocardium. Imaging of excised hearts from four animals showed an excellent correlation with in vivo imaging as well as gross pathology. Five animals with nonbacterial thrombotic aortic valve endocarditis demonstrated similar scintigraphic and tissue distribution results. In contrast, four normal animals failed to demonstrate abnormal /sup 99m/Tc-PYP cardiac scintigrams or tissue uptake. This study demonstrates that /sup 99m/Tc-PYP cardiac scintigraphy is a sensitive technique to detect experimental aortic valve endocarditis

  2. Increased uptake of technetium-99m methylene diphosphonate in muscles in the course of polymyositis

    International Nuclear Information System (INIS)

    Niemir, Z.; Oleksa, R.; Czepczynski, R.; Sowinski, J.

    2005-01-01

    A case of a woman aged 46 years with signs of rhabdomyolysis and acute renal failure is presented. Coxsackie serum test was positive. Increased uptake of Technetium-99m methylene diphosphonate ( 99mT c-MDP) by muscles of thighs and calves was observed. After 1 year no increased accumulation of radiotracer in the muscles was found

  3. In vitro evaluation of canine leukocytes radiolabeled in whole blood with 99mTc stannous colloid

    International Nuclear Information System (INIS)

    Abushhiwa, Mohamed H.; Salehi, Nouria S.; Whitton, Robert C.; Charles, Jennifer A.; Finnin, Peter J.; Lording, Peter M.; Caple, Ivan W.; Parry, Bruce W.

    2008-01-01

    Introduction: Technetium-99m stannous colloid ( 99m TcSnC)-labeled leukocytes are used to investigate a variety of inflammatory diseases in human medicine. The present study investigates the in vitro behavior of canine leukocytes labeled in whole blood with 99m TcSnC. Methods: Blood samples from 10 healthy dogs were labeled with 99m TcSnC using a standard procedure. The distribution of radioactivity among blood components (plasma, leukocyte layers and erythrocytes) was measured following separation of the radiolabeled samples across Histopaque density gradients. Phagocytic function of labeled and unlabeled leukocytes was estimated using zymosan particles. Labeling retention by leukocytes was determined at 1, 3, 4 and 7 h postlabeling. Results: The mean±standard error percentage of radioactivity associated with plasma, erythrocyte and leukocyte fractions was 2.0±0.21%, 55.5±0.60% and 42.5±0.54%, respectively (the last comprising 70.2±0.83% in polymorphonuclear leukocytes and 29.8±0.83% in mononuclear leukocytes). Labeled canine leukocytes had a phagocytic activity of 91.3±0.28% (control, 91.7±0.26%). The radiolabeled canine leukocytes retained 94.1±0.30% of radioactivity at 7 h postlabeling. Conclusions: Radiolabeling of canine leukocytes in whole blood with 99m TcSnC has minor adverse effect on their phagocytic function. The radiolabeled canine leukocytes retained a large percentage of radioactivity for at least 7 h postlabeling

  4. [99mTc[TRODAT-1: a novel technetium-99m complex as a dopamine transporter imaging agent

    International Nuclear Information System (INIS)

    Kung Meiping; Stevenson, D.A.; Ploessl, K.; Meegalla, S.K.; Beckwith, A.; Essman, W.D.; Mu, M.; Lucki, I.; Kung, H.F.

    1997-01-01

    Technetium-99m is the most commonly used radionuclide in routine nuclear medicine imaging procedures. Development of 99m Tc-labeled receptor-specific imaging agents for studying the central nervous system is potentially useful for evaluation of brain function in normal and disease states. A novel 99m Tc-labeled tropane derivative, [ 99m Tc[TRODAT-1, which is useful as a potential CNS dopamine transporter imaging agent, was evaluated and characterized. After i.v. injection into rats, [ 99m Tc[TRODAT-1 displayed specific brain uptake in the rat striatal region (striatum-cerebellum/cerebellum ratio 1.8 at 60 min), where dopamine neurons are concentrated. The specific striatal uptake could be blocked by pretreating rats with a dose of competing dopamine transporter ligand, β-CIT (or RTI-55, i.v., 1 mg/kg). However, the specific striatal uptake of [ 99m Tc[TRODAT-1 was not affected by co-injection of excess free ligand (TRODAT-1, up to 200 μg per rat) or by pretreating the rats with haloperidol (i.v., 1 mg/kg). The specific uptake in striatal regions of rats that had prior 6-hydroxydopamine lesion in the substantia nigra area showed a dramatic reduction. The radioactive material recovered from the rat striatal homogenates at 60 min after i.v. injection of [ 99m Tc[TRODAT-1 showed primarily the original compound (>95%), a good indication of in vivo stability in brain tissue. Similar and comparable organ distribution patterns and brain regional uptakes of [ 99m Tc[TRODAT-1 were obtained for male and female rats. (orig./AJ). With 4 figs., 6 tabs

  5. Experimental studies of the physiologic properties of technetium-99m agents: Myocardial transport of perfusion imaging agents

    International Nuclear Information System (INIS)

    Meerdink, D.J.; Leppo, J.A.

    1990-01-01

    The physiologic properties of new technetium-99m-labeled myocardial imaging agents (Tc-99m sestamibi, an isonitrile; and Tc-99m teboroxime, a boronic acid adduct of technetium dioxime) are discussed and compared to thallium-201 (Tl-201). Studies with isolated hearts, subcellular fractions and cell cultures indicate that Tc-99m sestamibi, Tc-99m teboroxime and Tl-201 do not share common transport or sequestration mechanisms. Although peak Tc-99m sestamibi myocardial extraction over time is about half that of Tl-201 at equivalent coronary blood flows, the amount of Tc-99m sestamibi that remains in the heart is similar to that of Tl-201 because of its higher retention efficiency. The high retention efficiency for Tc-99m sestamibi also results in minimal redistribution. In contrast, Tc-99m teboroxime myocardial extraction is higher than that of Tl-201, but its retention is less efficient, resulting in relatively rapid washout characteristics which may quickly result in tracer redistribution. During reperfusion after a no-flow period, Tc-99m sestamibi extraction and retention increase, but for Tc-99m teboroxime and Tl-201 these values tend to decrease. All tracers show adequate transport characteristics for perfusion imaging, and differences in transport and retention should lead to the development of new clinical protocols.27 references

  6. Localization of the acute lower gastrointestinal hemorrhage in vivo-in vitro labeling of red blood cells with sup(99m)Tc

    International Nuclear Information System (INIS)

    Noguera, E.; Mothe, G.; Wyse, E.

    1984-01-01

    For the detection and localization of acute lower gastrointestinal hemorrhage in vivo-in vitro labeling of red blood cells with sup(99m)Tc and sup(99m)Tc sulfur colloid has been sugested. The procedure for labeling RBC with sup(99m)Tc consisted in injecting IV 1 mg of ClSn; 20 minutes after injection of tin 10 cc of blood were withdrawn in a syringe containing 20 mCi of sup(99m)Tc; this was incubated for 10 minutes and then injected IV. Scintigraphy of the abdominal cavity was done in supine position and performed with a large field gamma camera with a parallel hole-low energy colimator. Computer adquisition of images was started 5 minutes after RBC injection and made at the rate of one enery 5 minutes for 45 minutes. 14 patients were studied divided in: a) control: 6 patients. b) with active gastrointestinal hemorrhage: 4 patients had positive scintigraphy. The hemorrhage was documented with superior mesenteric arteriography, endoscopy and/or necropsy. The sensitivity was 100%. In 4 out of 14 patients scintigraphy with sup(99m)Tc RBC compared with simultaneous sup(99m)Tc sulfur colloid demonstrated that all patients with positive sup(99m)Tc RBC had also positive sup(99m)Tc sulfur colloid scintigraphy. c) without active gastrointestinal hemorrhage: all of them had negative scintigraphy (specificity 100%). Abdominal scintigraphy with sup(99m)Tc RBC or sulfur colloid are both sensitive for detection and localization of lower gastrointestinal bleeding and the negative study suggests the absence of active hemorrhage. It is suggested that the sup(99m)Tc sulfur colloid scintigraphy should be the initial procedure to study these patients and abdominal arteriography should be performed only in patients with positive abdominal scintigraphy. (M.E.L.) [es

  7. Technetium-99m DMSA preparation: Trivial issues causing severe problems

    International Nuclear Information System (INIS)

    Kumar, V.

    1997-01-01

    Urinary tract infection (UTI) in children involving renal parenchyma, upper collecting system or bladder is one of the major causes for consideration in the diagnosis and management of paediatric nuclear medicine. Acute pyelonephritis is one of the prime causes of morbidity associated with urinary tract infection in children which can lead to progressive renal damage. Technetium-99m dimercaptosuccinic acid (DMSA) is used extensively for the assessment of UTI in paediatrics. The radiopharmaceutical preparation could be influenced by several factors, most of them are trivial, but invariably have severe impact on the quality of the scintiphotographs. This communication is mainly to highlight some of the issues related to 99 mTc-DMSA preparation and the possible precautionary measures that need to be taken to obviate unwarranted problems. (author)

  8. Biodistribution of {sup 99m} technetium labeled creatinine in healthy rats

    Energy Technology Data Exchange (ETDEWEB)

    Yilmaz, O. [Dokuz Eylul University, Narlidere, Izmir (Turkey). Medical Faculty. Dept. of Animal Research Center; Soylu, A.; Kavukcu, S. [Dokuz Eylul University, Narlidere, Izmir (Turkey). Medical Faculty. Dept. of Pediatrics; Lambrecht, F. Yurt; Durkan, K. [Ege University, Bornova, Izmir (Turkey). Institute of Nuclear Sciences. Dept. of Nuclear Applications]. E-mail: s.kavukcu@deu.edu.tr

    2007-06-15

    The distribution of creatinine, one of the toxic guanidine compounds, in various tissues has not been studied in detail by using radiolabeled creatinine. Our objective was to investigate the biodistribution of creatinine labeled with {sup 99m}technetium ({sup 99m} Tc) by the stannous (II) chloride method in healthy male Wistar rats. Quality controls were carried out by radio thin layer chromatography, high-performance liquid chromatography, and paper electrophoresis. The labeling yield was 85 {+-} 2% under optimum conditions (pH 7 and 100 {mu}g stannous chloride). Rats (N 12) were injected intravenously with {sup 99m} Tc creatinine and their blood and visceral organs were evaluated for {sup 99m} Tc-creatinine uptake as percent of the injected dose per gram wet weight of each tissue (%ID/g). The lowest amount of uptake was detected in the brain and testis. When the rate of uptake was evaluated, only the kidney showed increasing rates of uptake of {sup 99m} Tc-creatinine throughout the study. Kidneys showed the highest amount of uptake throughout the study (P < 0.001 compared to all other organs), followed by liver, spleen and lung tissue. (author)

  9. Migration pathways of hypodermically injected technetium-99 m in dogs

    International Nuclear Information System (INIS)

    Kovacs, F.M.; Mufraggi, N.; Garcia, A.; Pavia, J.; Giralt, I.; Piera, C.; Setoain, J.; Garcia, F.; Prandi, D.; Gotzens, V.

    2000-01-01

    Hypodermic injection of technetium-99 m ( 99 m TC-pertechnetate) at points of low electrical resistance give rise to rapid, longitudinal, and progressive diffusion of the radioactive tracer. We assessed the effect of cutaneous incisions that did not intersect the migration trajectory of 99 m Tc-pertechnetate and the re-establishment of pathways after the suture of incisions that intersected the migration trajectory. Linear and rapid migration of 99 m Tc-pertechnetate was not altered or prevented by incisions that did not intersect the migration pathway. Different patterns of 99 m Tc-pertechnetate spread were found when incisions intersected the radioactive pathways until restoration of the normal migration pathway observed in undamaged skin occurred. In all experiments in which migration of 99 m Tc-pertechnetate was observed, lavage of surgical wounds was followed by disappearance of the 99 m Tc-pertechnetate migration observed around the suture. Linear migration of the tracer was not observed when the incision was left uncovered, filled with petroleum jelly, or with a solid silicone sheet, but it was seen when non-sutured incisions were filled with transonic or silicone gel or covered with a solid silicone sheet parallel to the cutaneous plane. These data show that after a cutaneous incision that intersected the diffusion trajectory of the radioactive tracer, linear migration of 99 m Tc-pertechnetate hypodermically injected at points of low electrical resistance was restored before healing of the cutaneous incision and was independent of incisions made on the skin not overlying the radioactive pathway. A mechanism similar to that of capillary electrophoresis is suggested to explain the hypodermic diffusion of inert particles through specific and constant linear pathways. (orig.)

  10. Evaluation of the liver scintigraphy with /sup 99m/Tc-Sn-colloid. II. C Clinical studies by comparison with /sup 198/Au-colloid

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, K; Nishimura, T; Takeda, H; Furukawa, T [Osaka Univ. (Japan). Faculty of Medicine; Kajiya, Fumihiko

    1975-08-01

    Clinical significance of the liver scintigraphy with sup(99m)Tc-Sn-colloid was evaluated in comparison with those with /sup 198/Au-colloid. The liver scintigrams with sup(99m)Tc-Sn-colloid and /sup 198/Au-colloid were done in 36 cases of various hepatic diseases and RI accumulation curves in the liver and the spleen, and the blood disapearance curves were also obtained. The conclusions were as follows. The liver scintigrams with sup(99m)Tc-Sn-colloid proved to be more sensitive in the detection of tumors, especially, in the lower margin, left lobe and superficial layers of the liver than those with /sup 198/Au-colloid. In all cases, including normal and cirrhotic subjects, visualizations of the spleen were seen on the scintigrams with sup(99m)Tc-Sn-colloid. In diffuse hepatic diseases, comparing both radiopharmaceuticals, the splenic accumulations were studied qualitatively and quantitatively. As a result, the ratio (spleen/liver) was thought to be useful for the differentiation of diffuse hepatic diseases concerned with splenic function and/or size. It was also shown that sup(99m)Tc-Sn-colloid was useful as a spleen scanning agent. The Tl/2 in the liver accumulation curves with sup(99m)Tc-Sn-colloid were not as clearly differentiated in the various hepatic diseases as those with /sup 198/Au-colloid where those indexes were useful in the evaluation of liver functions.

  11. Technetium-99m ceftizoxime kit preparation

    Directory of Open Access Journals (Sweden)

    Simone Odília Fernandes Diniz

    2005-10-01

    Full Text Available The aim of this work was to prepare a kit of 99mTc-ceftizoxime (99mTc-CFT, with stability and biological activity preserved, able to identify a septic focus (E. coli in the experimental infection model in rats. The preparation of the CFT kit involved the use of lyophilized solutions containing the antibiotic ceftizoxime and the sodium dithionite reducing agent (6.0 mg/mL. After lyophilization, the kit was reconstituted with 1.0 mL of sodium 99mTc-pertechnetate solution (Na99mTcO4- with an activity of 370 MBq. The solution was boiled for 10 min and filtered through a cellulose ester filter. The labeling efficiency was on the order of 92%, remaining stable for six hours and the kit remained stable for two months. The biological activity of the 99mTc-CFT was evaluated by diffusion in agar impregnated with E.coli and S. aureus. Seven Wistar rats, weighing from 200 to 250 g, were used for the development of the septic focus. After 24 hours from the induction of the infectious site (E.coli, the animals were anesthetized and 0.1 mL of 99mTc-CFT (37 MBq was injected into the tail veins of the animals. The images were obtained with a gamma camera one, two and six hours after injection and the regions of interest (ROIs were calculated. The diameters of the inhibition halos for 99mTc-CFT were 27.16 ± 0.23 and 27.17 ± 0.20 for S.aureus and E.coli, respectively, while those for the unlabeled CFT were 30.4 ± 0.33 and 29.43 ± 0.26, respectively. The results for the biodistribution of 99mTc-CFT in infected animals furnished a ratio of 1.97 ± 0.31, 2.10 ± 0.42 and 2.01 ± 0.42 for cpm-target/cpm-no target for the one, two and six-hour periods, respectively. The images showed a clear uptake of labeled antibiotic (99mTc-CFT by the infectious site during the experiment. The results attest to the viability of producing a kit with 99m technetium-labeled ceftizoxime for the investigation of infectious processes.O objetivo deste trabalho foi preparar um kit de Tc

  12. Kit development for labelling erythrocytes or leukocytes with technetium-99m in vitro

    International Nuclear Information System (INIS)

    Wang Xuebin; Han Quansheng; Wang Jingcheng; Mi Hongzhi

    1996-01-01

    This study developed a modified pre tinning method for labeling erythrocytes with technetium-99m in vitro using a kit which contains stannous chloride stabilized with geneticist acid (GA) in lyophilized form. This GA-kit a sterile closed system that does not require centrifugation,washing and separation of the RBCs. The kit is simple to use and labeling takes ∼ 30 min with a typical labeling efficiency of 97.3% ± 1.2% for 60 determinations. Imaging studies were performed in rabbit using GA-kit in vitro labeling procedure and PYP-kit in vivo labeling. It shows that the heart-to-background ratio with GA in vitro labeling were significantly higher than with in vivo labeling. Leukocytes labeling with technetium-99m using the same GA kit also was studied. The labeling efficiency was 20 ∼ 41%. Thus, the GA kit is versatile and cost-effective. (author). 21 refs., 5 figs., 2 tabs

  13. Technetium-99m-Labeled Autologous Serum Albumin: A Personal-Exclusive Source of Serum Component

    OpenAIRE

    Wang, Yuh-Feng; Chen, Yi-Chun; Li, Dian-Kun; Chuang, Mei-Hua

    2011-01-01

    Technetium-99m human serum albumin (99mTc-HSA) is an important radiopharmaceutical required in nuclear medicine studies. However, the risk of transfusion-transmitted infection remains a major safety concern. Autopreparation of serum component acquired from patient provides a “personal-exclusive” source for radiolabeling. This paper is to evaluate the practicality of on-site elusion and subsequent radiolabeling efficacy for serum albumin. Results showed that the autologous elute contained more...

  14. Studies of liver scintigram by sup(99m)Tc-sodium phytate

    International Nuclear Information System (INIS)

    Abe, Masahide; Matsui, Kengo; Chiba, Kazuo; Yamada, Hideo; Iio, Masahiro

    1974-01-01

    Inositol hexaphosphate occurs in nature either free or in compounds (phytic acid). It is soluble in water and becomes a microcolloid by chelating serum calcium after intravenous injection, and forming insoluble calcium phytate, which undergoes reticuloendothelial localization. Case reports were made on all patients who had liver scan studies between August and December, 1973. Eighty-eight patients were studied with a total of 96 liver scans with sup(99m)Tc-phytate. Among these, the hepatic blood flow of eighteen were studied with sup(99m)Tc-phytate and 198 Au-colloid simultaneously. Labeling of sup(99m)Tc-phytate was easy, it remained stable for a long time and only a few free technetium were revealed (labeling yield: average 93.6%). The blood clearance of sup(99m)Tc-phytate was slower than that of 198 Au-colloid. This suggests that the liver scan must begin more than twenty minutes after the injection. Comparing their affinities for the reticuloendothelial system, sup(99m)Tc-phytate shows a greater accumulation in the spleen than does 198 Au-colloid. sup(99m)Tc-phytate is a useful diagnostic scanning agent of the liver and spleen. Because of its superior physical characteristics excellent scans are readily obtained with minimal radiation to the patient and there have been no side effects who have received sup(99m)Tc-phytate. (author)

  15. Technetium-99m carboxymethylcellulose: A newly developed fibre marker for gastric emptying studies

    International Nuclear Information System (INIS)

    Schade, J.H.; Hoving, J.; Brouweres, J.R.B.J.; Riedstra-van Gent, H.G.; Zijlstra, J.; Dijkstra, J.P.H.

    1991-01-01

    We report a study of technetium-99m-labelled carboxymethyl-cellulose ( 99m Tc-CMC) as a newly developed non-digestible marker of the solid phase of gastric contents. The radiosynthesis is simple and shows a high labelling efficiency. In vitro and in vivo experiments demonstrated stability of the marker in the gastrointestinal tract during the process of gastric emptying. The gastric half-emptying time in ten healthy volunteers of both sexes was 105±17 min (mean±SD). This rate of gastric emptying is similar to that of non-digestible solid-phase markers such as in vivo labelled 99m Tc-chicken liver or radio-iodinated cellulose. In comparison with digestible solid-phase markers such as 99m Tc-labelled pancake or 99m Tc-cooked egg, gastric emptying of 99m Tc-CMC occurred more slowly, confirming the expected behaviour of a non-digestible solid-phase marker. We conclude that 99m Tc-CMC has the advantage of a simple and rapid labelling procedure and may be useful for clinical studies of gastric emptying. (orig.)

  16. A solvent-extraction module for cyclotron production of high-purity technetium-99m.

    Science.gov (United States)

    Martini, Petra; Boschi, Alessandra; Cicoria, Gianfranco; Uccelli, Licia; Pasquali, Micòl; Duatti, Adriano; Pupillo, Gaia; Marengo, Mario; Loriggiola, Massimo; Esposito, Juan

    2016-12-01

    The design and fabrication of a fully-automated, remotely controlled module for the extraction and purification of technetium-99m (Tc-99m), produced by proton bombardment of enriched Mo-100 molybdenum metallic targets in a low-energy medical cyclotron, is here described. After dissolution of the irradiated solid target in hydrogen peroxide, Tc-99m was obtained under the chemical form of 99m TcO 4 - , in high radionuclidic and radiochemical purity, by solvent extraction with methyl ethyl ketone (MEK). The extraction process was accomplished inside a glass column-shaped vial especially designed to allow for an easy automation of the whole procedure. Recovery yields were always >90% of the loaded activity. The final pertechnetate saline solution Na 99m TcO 4 , purified using the automated module here described, is within the Pharmacopoeia quality control parameters and is therefore a valid alternative to generator-produced 99m Tc. The resulting automated module is cost-effective and easily replicable for in-house production of high-purity Tc-99m by cyclotrons. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Effects of neutron irradiation on red blood cell labeling with technetium-99m

    International Nuclear Information System (INIS)

    Eng, R.R.; Conklin, J.J.; Grissom, M.P.

    1982-01-01

    The effects of in vivo and in vitro neutron irradiation on red blood cell radiolabeling with technetium-99m (Tc-99m) were studied. Blood from three dogs was irradiated with neutrons (725 rads, free in air dose) followed by radiolabeling with Tc-99m. The three dogs were subsequently whole body, neutron irradiated (250 rads, midline dose); and blood samples were drawn for radiolabeling at 24, 48, 72 and 96 hours post-irradiation. Blood from three control dogs was also drawn and radiolabeled on each day for comparison. The results show that there were no significant differences between the radiolabeling capacities of in vivo or in vitro neutron irradiated and control RBCs

  18. Uptake of radiocolloid, (2). Lung uptake of sup(99m)Tc-Sn-colloid during liver scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Y [Showa Univ., Tokyo (Japan). School of Medicine

    1980-10-01

    Forty-one of RI lung accumulation were selected from 1536 cases among liver scintigraphy of sup(99m)Tc-Sn-colloid. The results of analysis of these cases are as follows: 1) The cases of lung accumulation caused by failure of preparing sup(99m)Tc-Sn-colloid were excluded. The lung accumulation in liver scintigraphy was able to be found only in sup(99m)Tc-Sn-colloid with large sized particle. 2) From several facts, it is not considered that sup(99m)Tc-colloid was taken into the lung in form of macroaggregation after injection. 3) The lung accumulation of sup(99m)Tc-colloid was not always detected in the cases with any liver disorder. 4) The great majority of cases with the lung accumulation were malignant tumor, the next was liver cirrhosis. When the patients were in the most severe condition, sup(99m)Tc-colloid was apt to be revealed in the lung. In the cases of children, the marked accumulation of the lung was always observed. 5) The lung accumulation of sup(99m)Tc-Sn-colloid was also observed in many patients with splenomegaly without liver disease. It is not a phenomena from the result of decrease in hepatic blood flow or of portal hypertension, but it may be related with certain immunological change. 6) Most patients with the lung accumulation were in extremely severe condition and their survival was not so good. Therefore, this phenomena could refer to a indicator of poor prognosis. 7) The lung accumulation of RI colloid may be revealed when patients fall into extremely severe stage and pulmonary macrophages are stimulated. Its phenomena would be essentially caused by a mechanism that RI-colloid are phagocyted by pulmonary macrophages.

  19. Technetium {sup 99m}Tc Pertechnetate Brain Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Rhee, Sang Min; Park, Jin Yung; Lee, Ahn Ki; Chung, Choo Il; Hong, Chang Gi [Capital Army Hospital, ROKA, Seoul (Korea, Republic of); Rhee, Chong Heon; Koh, Chang Soon [Radiological Research Institute, Seoul (Korea, Republic of)

    1968-03-15

    Technetium {sup 99}mTc pertechnetate brain scanning were performed in 3 cases of head injury (2 chronic subdural hematomas and 1 acute epidural hematoma), 2 cases of brain abscess and 1 case of intracerebral hematoma associated with arteriovenous anomaly. In all the cases brain scintigrams showed 'hot areas.' Literatures on radioisotope scanning of intracranial lesions were briefly reviewed. With the improvement of radioisotope scanner and development of new radiopharmaceuticals brain scanning became a safe and useful screening test for diagnosis of intracranial lesions. Brain scanning can be easily performed even to a moribund patient without any discomfort and risk to the patient which are associated with cerebral angiography or pneumoencephalography. Brain scanning has been useful in diagnosis of brain tumor, brain abscess, subdural hematoma, and cerebral vascular diseases. In 80 to 90% of brain tumors positive scintigrams can be expected. Early studies were done with 203 Hg-Neohydrin or {sup 131}I-serum albumin. With these agents, however, patients receive rather much radiation to the whole body and kidneys. In 1965 Harper introduced {sup 99}mTc to reduce radiation dose to the patient and improve statistical variation in isotope scanning.

  20. Contribution to the study of the red blood cells labelled with chromium-51 and technetium-99 m

    International Nuclear Information System (INIS)

    Canine, M.S.

    1983-01-01

    Although the bindings of Cr-51 and Tc-99 m were both in the β chain of hemoglobin molecule, the results obtained after previous incubations of the RBC with chromium and technetium, and the determinations of the efficiency of the labeling of RBC showed that the points of fixing of chromium and technetium with β chain of hemoglobin were probably different. The observations through the optic microscope allowed the verification that, at the concentration of 100 mg/ml of Cr-50, there were morphologic in the RBC. These modifications were not found after the other treatments. The comparison between scintigraphy obtained with Tc-99 m or Cr-51 RBC suggested that the technique which employs Tc-99 m can be more adequate than the one with Cr-51. (author)

  1. [{sup 99m}Tc]TRODAT-1: a novel technetium-99m complex as a dopamine transporter imaging agent

    Energy Technology Data Exchange (ETDEWEB)

    Meiping, Kung [Department of Radiology, University of Pennsylvania, Philadelphia (United States); Stevenson, D A [Department of Radiology, University of Pennsylvania, Philadelphia (United States); Ploessl, K [Department of Radiology, University of Pennsylvania, Philadelphia (United States); Meegalla, S K [Department of Radiology, University of Pennsylvania, Philadelphia (United States); Beckwith, A [Department of Radiology, University of Pennsylvania, Philadelphia (United States); Essman, W D [Department of Psychiatry, University of Pennsylvania, Philadelphia (United States); Mu, M [Department of Radiology, University of Pennsylvania, Philadelphia (United States); Lucki, I [Department of Psychiatry, University of Pennsylvania, Philadelphia (United States); [Department of Pharmacology, University of Pennsylvania, Philadelphia (United States); Kung, H F [Department of Radiology, University of Pennsylvania, Philadelphia (United States); [Department of Pharmacology, University of Pennsylvania, Philadelphia (United States)

    1997-04-01

    Technetium-99m is the most commonly used radionuclide in routine nuclear medicine imaging procedures. Development of {sup 99m}Tc-labeled receptor-specific imaging agents for studying the central nervous system is potentially useful for evaluation of brain function in normal and disease states. A novel {sup 99m}Tc-labeled tropane derivative, [{sup 99m}Tc]TRODAT-1, which is useful as a potential CNS dopamine transporter imaging agent, was evaluated and characterized. After i.v. injection into rats, [{sup 99m}Tc]TRODAT-1 displayed specific brain uptake in the rat striatal region (striatum-cerebellum/cerebellum ratio 1.8 at 60 min), where dopamine neurons are concentrated. The specific striatal uptake could be blocked by pretreating rats with a dose of competing dopamine transporter ligand, {beta}-CIT (or RTI-55, i.v., 1 mg/kg). However, the specific striatal uptake of [{sup 99m}Tc]TRODAT-1 was not affected by co-injection of excess free ligand (TRODAT-1, up to 200 {mu}g per rat) or by pretreating the rats with haloperidol (i.v., 1 mg/kg). The specific uptake in striatal regions of rats that had prior 6-hydroxydopamine lesion in the substantia nigra area showed a dramatic reduction. The radioactive material recovered from the rat striatal homogenates at 60 min after i.v. injection of [{sup 99m}Tc]TRODAT-1 showed primarily the original compound (>95%), a good indication of in vivo stability in brain tissue. Similar and comparable organ distribution patterns and brain regional uptakes of [{sup 99m}Tc]TRODAT-1 were obtained for male and female rats. (orig./AJ). With 4 figs., 6 tabs.

  2. TESTING GUIDELINES FOR TECHNETIUM-99 ADSORPTION ON ACTIVATED CARBON

    International Nuclear Information System (INIS)

    Byrnes, M.E.

    2010-01-01

    CH2M HILL Plateau Remediation Company (CHPRC) is currently evaluating the potential use of activated carbon adsorption for removing technetium-99 from groundwater as a treatment method for the Hanford Site's 200 West Area groundwater pump-and-treat system. The current pump-and-treat system design will include an ion-exchange (IX) system for selective removal of technetium-99 from selected wells prior to subsequent treatment of the water in the central treatment system. The IX resin selected for technetium-99 removal is Purolite A530E. The resin service life is estimated to be approximately 66.85 days at the design technetium-99 loading rate, and the spent resin must be replaced because it cannot be regenerated. The resulting operating costs associated with resin replacement every 66.85 days are estimated at $0.98 million/year. Activated carbon pre-treatment is being evaluated as a potential cost-saving measure to offset the high operating costs associated with frequent IX resin replacement. This document is preceded by the Literature Survey of Technetium-99 Groundwater Pre-Treatment Option Using Granular Activated Carbon (SGW-43928), which identified and evaluated prior research related to technetium-99 adsorption on activated carbon. The survey also evaluated potential operating considerations for this treatment approach for the 200 West Area. The preliminary conclusions of the literature survey are as follows: (1) Activated carbon can be used to selectively remove technetium-99 from contaminated groundwater. (2) Technetium-99 adsorption onto activated carbon is expected to vary significantly based on carbon types and operating conditions. For the treatment approach to be viable at the Hanford Site, activated carbon must be capable of achieving a designated minimum technetium-99 uptake. (3) Certain radionuclides known to be present in 200 West Area groundwater are also likely to adsorb onto activated carbon. (4) Organic solvent contaminants of concern (COCs) will

  3. TESTING GUIDELINES FOR TECHNETIUM-99 ABSORPTION ON ACTIVATED CARBON

    Energy Technology Data Exchange (ETDEWEB)

    BYRNES ME

    2010-09-08

    CH2M HILL Plateau Remediation Company (CHPRC) is currently evaluating the potential use of activated carbon adsorption for removing technetium-99 from groundwater as a treatment method for the Hanford Site's 200 West Area groundwater pump-and-treat system. The current pump-and-treat system design will include an ion-exchange (IX) system for selective removal of technetium-99 from selected wells prior to subsequent treatment of the water in the central treatment system. The IX resin selected for technetium-99 removal is Purolite A530E. The resin service life is estimated to be approximately 66.85 days at the design technetium-99 loading rate, and the spent resin must be replaced because it cannot be regenerated. The resulting operating costs associated with resin replacement every 66.85 days are estimated at $0.98 million/year. Activated carbon pre-treatment is being evaluated as a potential cost-saving measure to offset the high operating costs associated with frequent IX resin replacement. This document is preceded by the Literature Survey of Technetium-99 Groundwater Pre-Treatment Option Using Granular Activated Carbon (SGW-43928), which identified and evaluated prior research related to technetium-99 adsorption on activated carbon. The survey also evaluated potential operating considerations for this treatment approach for the 200 West Area. The preliminary conclusions of the literature survey are as follows: (1) Activated carbon can be used to selectively remove technetium-99 from contaminated groundwater. (2) Technetium-99 adsorption onto activated carbon is expected to vary significantly based on carbon types and operating conditions. For the treatment approach to be viable at the Hanford Site, activated carbon must be capable of achieving a designated minimum technetium-99 uptake. (3) Certain radionuclides known to be present in 200 West Area groundwater are also likely to adsorb onto activated carbon. (4) Organic solvent contaminants of concern (COCs

  4. Study with radio aerosol of DTPA technetium-99 m in individuals with pulmonary disease by amiodarone

    International Nuclear Information System (INIS)

    Terra Filho, M.

    1989-01-01

    In order to evaluate the role of the clearance of 99 m Technetium chelated to diethylenetriamine-penta-acetate (99 m Tc-DTPA) in amiodarone induced pulmonary disease, 40 individuals were studied in four groups. After spirometry, where a volume-time curve was registered, all individuals inhaled 740 MBq of 99 m Tc-DTPA diluted in 4 ml of saline, for five minutes. Pulmonary images were obtained in a computerized scintillation camera and 9 regions of interest were selected. (author)

  5. Lymphoma imaging with a new technetium-99m labelled antibody, LL2

    International Nuclear Information System (INIS)

    Murthy, S.; Sharkey, R.M.; Goldenberg, D.M.; Lee, R.E.; Pinsky, C.M.; Hansen, H.J.; Burger, K.; Swayne, L.C.

    1992-01-01

    The lesion detection capability of a new technetium-99m labelled B-cell lymphoma monoclonal antibody (MoAb) imaging agent, LL2, was evaluated in 8 patients with non-Hodgkin's lymphoma and 1 patient with chronic lymphocytic leukaemia. The MoAb kit consists of a 1-vial, 1-mg Fab' form of LL2 ready for instant labelling with technetium. The patients were injected with ∝925 MBq (25 mCi) of 99m Tc-LL2 Fab' (1 mg), and planar and single photon emission tomography (SPET) studies were performed at 3-4 h post injection and at 24 h. There was no evidence of thyroid or stomach activity up to 24 h. Uniform splenic uptake was seen in all patients. Two non-lymphoma patients were also administered with the same agent and demonstrated a similar splenic distribution; therefore, splenic targeting was not scored as tumour-specific. A total of 29 from 48 tumour sites were detected by scintigraphy, including tumours of various grades and histological types. Excluding 1 patient who had a large tumour burden of over 500 g, 29 of 33 lesions were detected. One patient was free of disease at the time of the study and had a negative scan. Another patient showed excellent targeting of gallium-negative sites in the liver and bone. The bone involvement was not known prior to the antibody study and was subsequently confirmed by a bone scan. Additional sites of MoAb localization could not be followed in this group, since most patients went on to radioimmunotherapy immediately following the 99m Tc-LL2 study. However, these initial results suggest that this new 99m Tc-labelled antibody imaging kit should be further investigated for its potential role in the staging and follow-up of lymphoma patients. (orig.)

  6. Technetium-99m colloidal bismuth subcitrate: A novel method for the evaluation of peptic ulcer disease

    International Nuclear Information System (INIS)

    Vasquez, T.E.; Lyons, K.P.; Raiszadeh, M.; Fardi, M.; Snider, P.

    1984-01-01

    The therapeutic agent colloidal bismuth subcitrate (CBS) selectively binds to peptic ulcers. The authors have developed a method for labeling this agent with Tc-99m. Chromatographic quality control studies of the agent on silica gel coated strips (ITLC-SG) showed that more than 97% of Tc-99m was bound to CBS. During in-vitro stability testing, the radio-label was stable for a minimum of 6 hours. The chromatographic findings are in agreement with the in-vivo distribution of the agent which showed no significant radioactivity in thyroid, kidneys, liver, or bladder. The resulting Tc-99m-CBS solution is administered orally in drinking water. Preliminary animal studies have been conducted on 5 adult 3 kg New Zealand rabbits sedated with 50 mg Ketamine I.M. The rabbits were intubated with I.V. tubing advanced to the stomach. They were given a gastric erosive suspension of 600-1000 mg/kg of pulverized ASA in 10 cc tap water. Four hours later they were given 3-4 mCi of the radiotracer in a 5 cc volume of water. Serial in-vivo images were obtained for 2 hours which included thyroid, abdomen, and urinary bladder. Next the stomachs were excised, opened along the greater curvature, imaged, vigorously washed and reimaged. All 5 rabbits showed avid localized binding of radiotracer which remained fixed even with vigorous washing. Areas of normal appearing mucosa were relatively devoid of radiotracer. This new compound may have significant clinical usefulness in the detection of peptic ulcer disease. In addition, such a non-invasive technique, carrying none of the risks or discomfort of endoscopy could also find application in the evaluation of the response to therapy

  7. Specifications and Quality of Technetium99m Produced diopharmaceuticals According to Good Manufacturing Practice Regulations

    International Nuclear Information System (INIS)

    Abudaia, Jamal; Ben Othman, Monji H.; Maatoug, Maatoug A.; Maatoug, M. Omar

    2003-01-01

    A Technological revolution has occurred in the last two decades of this century in field of Cold Kits preparations processed by Lyophilization technique (A drying process while frozen) which are labeled afterwards with Technetium-99m radionuclide. Such materials are intended to be used as Radiopharmaceutical probes in nuclear medicine for the diagnosis of dynamic and static conditions of organs, and therefore; uncovering of diseases and syndromes targeting humans. Preferability and the advantages of such kits labeled with Technetium-99m radionuclide over other types of radiopharmaceuticals is attributed to the unique physical properties of the radionuclide including its short half life of 6.02 hours, low photon energy of 140 keV, lacking of alpha and beta particles which are usually exposing patients to have additional exposed doses. Moreover, simplicity in obtaining such radionuclide in form portable generators containing the mother radionuclide Molybdenum - 99 (i.e. solvent extraction generators or adsorption column chromatographic generators) for-on-the- spot-labeling, and the ability of formulating the cold kits as chemical complexes located at different organs of human body. Those lyophilized kits intended for radiopharmaceutical preparations labeled with Technetium - 99m radionuclide must stand for quality assurance standards and assessments for the sake of safety, efficiency, apyrogenecity, radiochemical purity, in- vivo stability and suitability for the endeavor planed for. Therefore, in order to control and optimize those considerations, implementations of the so-called GOOD MANUFACTURING PRACTICE composed of regulations and constitutional laws related to the process of preparation and final produced preparation must take place.(author)

  8. Use of 99mTc-HMPAO-leucocyte scintigraphy coupled to 99mTc-colloid scintigraphy in diagnosing the osteo-articular sepsis

    International Nuclear Information System (INIS)

    Darlas, Y.; Pegoix, M.; Filmont, J.E.; Leclercq, S.; Rosas, M.H.; Agostini, D.; Aubriot, J.H.; Bouvard, G.

    1997-01-01

    The object of this study was the scintigraphic diagnosis of osseous sepsis based on the absence of congruence between leucocytic and colloidal fixations and the evaluation of the effect of coupling between the scintigraphies (sc) with leucocytes (A) and colloids (B) on the diagnosis feasibility index of this technique. Seventy four patients, 97 sc were divided into two groups according to the scintigraphic technique [(A) only]: 35 sc; [(A) and (B)]: 62 sc. [Prosthesis: 48 patients, 68 sc. Osteitis: 26 patients, 29 sc]. The scintigraphies were performed as follows: (A) autologous leucocytes labelled by 250 - 300 MBq of 99m Tc-HMPAO, with planar incidences (15 min), 3 - 4 hours after injection and (B) Labelled nano-colloids labelled by 180 - 200 MBq of 99m Tc, the same incidences, 30 min after injection. The delay between (A) and (B): 48 hours. The final diagnosis of sepsis: bacteriological and histologic criteria after biopsies and/or clinical, biological and radiological evolution. The comparison between the two groups is given in a table in terms of prevalence, sensitivity and specificity, using the χ2 and Fisher tests. In conclusion, the scintigraphy by 99m Tc-HMPAO-leucocyte is a sensitive method (Se ∼ 90%) for the diagnosis of osseous sepsis and coupled to the scintigraphy by 99m Tc-colloids allow obtaining a high specificity (Sp ≥ 90%) by reducing the number of falsely positive diagnoses

  9. Sup(99m) Technetium - labeled red blood cells 'in vitro'

    International Nuclear Information System (INIS)

    Bernardo Filho, M.; Souza Moura, I.N. de; Boasquevisque, E.M.

    1983-01-01

    A simple technique for the preparation of sup(99m) Tc labeled red blood cells using a comercial kit is described. To each 3ml of plain blood with anti-coagulant was added 1ml of solution of commercial kit with 6.8 μg of stannous chloride. This mixture was incubated in water bath, at 37 0 C, for 60 minutes. Then technetium-99m was added and the mixture was left for another ten minutes, in water bath, at 37 0 C. Under these conditions there was the best labeling of the red blood cells. Similar results were obtained with a solution of stannous chloride prepared freshly. The labeling is strong for 6.8 μg stannous chloride because the labeling was not removed by the several washes of the red blood cells or by the left in water bath. (Author) [pt

  10. The use of technetium-99m-DTPA in the diagnosis of tuberculous meningitis

    International Nuclear Information System (INIS)

    Von Wenzel, K.S.

    1988-03-01

    As 82 Br is not available locally in South West Africa on a daily basis a technetium preparation, 99m Tc-DTPA, was used in the diagnosis of patients with tuberculous meningitis. The 99m Tc-DTPA partition test was compared with the 82 Br partition test on 22 trial subjects. The trial subjects varied in age (0,8-57 years), sex and race. There were 7 patients diagnosed by the clinicians as having tuberculous meningitis. All patients were placed on anti-tuberculous meningitis treatment and all, except 2, one of whom regressed and 1 who died 7 days later, improved slowly. The 9 patients with viral meningitis received no antibiotics and recovered rapidly on symptomatic treatment only. With all 5 the septic meningitis cases, the organism was identified and there was thus no diagnostic uncertainty. One normal control subject was also examined. It would appear from the results that both 82 Br, as well as 99m Tc-DTPA, cross the blood-brain barrier to a greater extent in the case of tuberculous meningitis, compared to viral meningitis. Although the accuracy of the 82 Br test, if a critical ratio value of 1,3 was chosen, is 90,6% compared to 86,9% of the 99m Tc-DTPA partition test if a critical ratio value of 3 was chosen, there are still advantages to the use of the technetium preparation. These include the availability, cost and lower radiation dose per MBq as well as the possibility of brain imaging. 10 figs., 58 refs., 9 tabs

  11. Neutrophil labeling with [99mTc]-technetium stannous colloid is complement receptor 3-mediated and increases the neutrophil priming response to lipopolysaccharide

    International Nuclear Information System (INIS)

    Gallagher, Hayley; Ramsay, Stuart C.; Barnes, Jodie; Maggs, Jacqueline; Cassidy, Nathan; Ketheesan, Natkunam

    2006-01-01

    Introduction: [ 99m Tc]-technetium stannous colloid (TcSnC)-labeled white cells are used to image inflammation. Neutrophil labeling with TcSnC is probably phagocytic, but the phagocytic receptor involved is not known. We hypothesised that complement receptor 3 (CR3) plays a key role. Phagocytic labeling could theoretically result in neutrophil activation or priming, affecting the behaviour of labeled cells. Fluorescence-activated cell sorter (FACS) analysis side scatter measurements can assess neutrophil activation and priming. Methods: We tested whether TcSnC neutrophil labeling is CR3-mediated by assessing if neutrophil uptake of TcSnC was inhibited by a monoclonal antibody (mAb) directed at the CD11b component of CR3. We tested if TcSnC-labeled neutrophils show altered activation or priming status, comparing FACS side scatter in labeled and unlabeled neutrophils and examining the effect of lipopolysaccharide (LPS), a known priming agent. Results: Anti-CD11b mAb reduced neutrophil uptake of TcSnC in a dose-dependent fashion. Labeled neutrophils did not show significantly increased side scatter compared to controls. LPS significantly increased side scatter in control cells and labeled neutrophils. However, the increase was significantly greater in labeled neutrophils than unlabeled cells. Conclusions: Neutrophil labeling with TcSnC is related to the function of CR3, a receptor which plays a central role in phagocytosis. TcSnC labeling did not significantly activate or prime neutrophils. However, labeled neutrophils showed a greater priming response to LPS. This could result in labeled neutrophils demonstrating increased adhesion on activated endothelium at sites of infection

  12. Complexes of technetium-99m with tetrapeptides, a new class of 99mTc-labelled agents

    International Nuclear Information System (INIS)

    Vanbilloen, Hubert P.; Bormans, Guy M.; Roo, Michel J. de; Verbruggen, Alfons M.

    1995-01-01

    is concluded that tetrapeptides are an interesting group of technetium complexing agents which can easily be labelled with 99m Tc at room temperature in alkaline medium. This class offers the possibility of a wide variety of derivatives, just by substituting one or more amino acids. This group of ligands thus opens a new research field of 99m Tc-complexes with potential usefulness in several areas

  13. Comparison study among methodologies of planar chromatography for radiochemical control of technetium-99m; Estudo comparativo entre metodologias de cromatografia planar para controle radioquimico de radiofarmacos de tecnecio-99m

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Elisiane de Godoy

    2012-07-01

    Radiopharmaceuticals are substances that have radioisotopes in their composition. About 95% of the procedures performed in nuclear medicine use radiopharmaceuticals with diagnostic purposes, and the Lyophilized Reagents (LR) labeled with Technetium-99m ({sup 99}mTc), obtained from {sup 99}Mo/{sup 99}mTc generator, are the most one used. Quality Control represents the set of assays to be performed to assure that the product is adequate to its purpose. An important feature to be evaluated in {sup 99m}Tc radiopharmaceuticals is the radiochemical purity (% RqP) to quantify free pertechnetate ({sup 99}mTcO{sub 4}{sup -}) and technetium colloidal (99mTcO{sub 2}) mainly by paper chromatography (PC), thin layer (TLC) and High Performance Liquid Chromatography (HPLC). The objective of this work was to perform the comparison among the radiochemical control methodologies of LR labeled with {sup 99m}Tc, described in the United States Pharmacopoeia (USP) and European Pharmacopoeia (EP) and those used by IPEN. {sup 99m}TcO{sub 4}{sup -} eluate and DISIDA, DMSA, DTPA, EC, ECD, GHA, MIBI, MDP, PIRO, SAH and Sn Coloidal LR were provided by IPEN-CNEN/SP. TLC-cellulose, TLC-SG.TLC-SG reverse phase, HPTLC-cellulose, HPTLC-SG (Merck) and ITLC-SG (Pall Corporation), W1MM, W3MM, W17M e W31ET (Whatman) chromatographic plates were used. The measurement of the radioactivity was done in a Perkin Elmer Cobra D-5002 gamma counter. LR were labeled to obtain 55,0 MBq mL{sup 1} (1,5 mCi mL{sup 1}) of final radioactive concentration. The %{sup 99m}TcO{sub 4}{sup -}, %{sup 99m}TcO{sub 2} and % RqP were determined up to 4 hour labeling. From 11 LR, only EC and GHA have no radiochemical control methods in USP and EP. In USP and/or EP, DTPA, MDP, PIRO, SAH and Sn Coloidal methods use ITLC-SG; IPEN uses this chromatography plate in DISIDA, EC, ECD, GHA, PIRO, MIBI and SAH. As ITLC-SG had been out of production (recommended in 40, 70 and 41% of the USP, EP and IPEN methodologies, respectively), it was

  14. Effect of technetium Tc 99m pertechnetate on bacterial survival in solution

    International Nuclear Information System (INIS)

    Stathis, V.J.; Miller, C.M.; Doerr, G.F.; Coffey, J.L.; Hladik, W.B.

    1983-01-01

    Survival of Staphylococcus epidermidis (10(2) organisms/ml) in solutions containing various levels of radioactivity was assessed. Six test preparations contained nonbacteriostatic 0.9% sodium chloride solution; four of these contained technetium Tc 99m pertechnetate (99mTcO-4) in various quantities (80, 250, 500, and 750 mCi). A fifth contained technetium that had decayed to an essentially nonradioactive form, and a sixth contained 0.9% sodium chloride solution only. Each of the six 20-ml solutions was inoculated with 2 ml of single-strength trypticase soy broth (TSB) containing 10(3) organisms/ml. At various times up to 12 hours after inoculation, 1-ml aliquots of each test solution were withdrawn and passed through 0.22-micron filters, thereby preventing further irradiation of the filtered organisms. The filters were incubated in single-strength TSB at 37 degrees C, and samples were examined for turbidity at 24, 48, and 72 hours. After 24 hours, 25 of the 36 sample tubes showed turbidity; after 48 hours, the turbid samples totaled 28. Bacteria in the two nonradioactive solutions remained viable throughout the 12-hour sampling period. Accumulated doses of radiation obtained in the 250-, 500-, and 750-mCi samples inhibited bacterial growth. To be a valid quality-control measure, sterility monitoring of prepared radiopharmaceutical dosage forms may need to be performed concurrently with their preparation

  15. Guava extract (Psidium guajava) alters the labelling of blood constituents with technetium-99m*

    Science.gov (United States)

    Abreu, P.R.C.; Almeida, M.C.; Bernardo, R.M.; Bernardo, L.C.; Brito, L.C.; Garcia, E.A.C.; Fonseca, A.S.; Bernardo-Filho, M.

    2006-01-01

    Psidium guajava (guava) leaf is a phytotherapic used in folk medicine to treat gastrointestinal and respiratory disturbances and is used as anti-inflammatory medicine. In nuclear medicine, blood constituents (BC) are labelled with technetium-99m (99mTc) and used to image procedures. However, data have demonstrated that synthetic or natural drugs could modify the labelling of BC with 99mTc. The aim of this work was to evaluate the effects of aqueous extract of guava leaves on the labelling of BC with 99mTc. Blood samples of Wistar rats were incubated with different concentrations of guava extract and labelled with 99mTc after the percentage of incorporated radioactivity (%ATI) in BC was determined. The results suggest that aqueous guava extract could present antioxidant action and/or alters the membrane structures involved in ion transport into cells, thus decreasing the radiolabelling of BC with 99mTc. The data showed significant (Pguava extract. PMID:16691636

  16. Technetium-99m somatostatin analogues: effect of labelling methods and peptide sequence

    International Nuclear Information System (INIS)

    Decristoforo, C.; Mather, S.J.

    1999-01-01

    In this paper the preclinical evaluation of the somatostatin analogue RC160 labelled with technetium-99m using bifunctional chelators (BFCs) based on the hydrazinonicotinamide (HYNIC) and N 3 S system is described and a comparison made with [Tyr 3 ]-octreotide (TOC). Conjugates of both peptides with HYNIC, and of RC160 with benzoyl-MAG 3 and an N 3 S-adipate derivative were prepared and radiolabelling performed at high specific activities using tricine, tricine/nicotinic acid and ethylenediamine-N,N'-diacetic adic (EDDA) as co-ligands for HYNIC conjugates. All conjugates and 99m Tc-labelled peptides showed preserved binding affinity for the somatostatin receptor (IC50, Kd 99m Tc-RC160 derivatives compared with 99m Tc-EDDA/HYNIC-[Tyr 3 ]-octreotide (0.2%-3.5%ID/g vs 9.7%ID/g) and correlated well with the reduced internalisation rate for RC160 derivatives. Our results show that the selection of the labelling approach as well as the right choice of the peptide structure are crucial for labelling peptides with 99m Tc to achieve complexes with favourable biodistribution. Despite the relatively low tumour uptake compared with 99m Tc-EDDA/HYNIC-[Tyr 3 ]-octreotide, 99m Tc-RC160 could play a role in imaging tumours that do not bind octreotide derivatives. (orig.)

  17. Thyrotoxic Graves' disease with normal thyroidal technetium-99m pertechnetate uptake

    Energy Technology Data Exchange (ETDEWEB)

    Ikekubo, Katsuji; Hino, Megumu; Ito, Hidetomi; Koh, Toshikiyo; Ishihara, Takashi; Kurahachi, Hiroyuki (Kobe City General Hospital (Japan)); Kasagi, Kanji; Hidaka, Akinari; Mori, Toru

    1990-07-01

    We saw 24 thyrotoxic Graves' patients with normal thyroidal uptake of technetium-99m pertechnetate ({sup 99m}Tc) out of 201 untreated thyrotoxic Graves' patients seen over 4 years. The clinical and laboratory findings for these patients were studied and analyzed. Thyroid uptake and scintigraphic examinations by means of {sup 99m}Tc, TBII and TSab activity measurement clearly distinguished these patients from other thyrotoxic disorders (destruction-induced thyrotoxicosis and autonomously functioning thyroid lesions). Different from other disorders, these patients had not lower but normal thyroid uptake and also showed diffuse and discrete trapping into the enlarged glands. These patients had significantly smaller goiters, a lower serum thyroid hormone level, and lower TBII and TSab activity, when compared with other high {sup 99m}Tc uptake groups with Graves' disease, and their condition could be easily controlled with small amounts of antithyroid drugs. Our study indicates that thyrotoxic Graves' disease with normal {sup 99m}Tc uptake exists and {sup 99m}Tc uptake study and TBII activity measurement is very useful for the diagnosis. The normal {sup 99m}Tc uptake thyrotoxic Graves' patient might be early stage patients with general Graves' disease and their early discrimination from general Graves' patients is very advantageous for treatment and prognosis. (author).

  18. The regulation of technetium-99 discharges at Sellafield

    International Nuclear Information System (INIS)

    Mayall, A.

    2002-01-01

    The reprocessing of spent Magnox fuel at BNFL Sellafield produces a liquid waste concentrate containing technetium-99 and other, more radiotoxic, radionuclides such as plutonium and americium. The concentrate is known as medium active concentrate (MAC). Prior to 1981, MAC was discharged to sea untreated after several years' storage, during which short-lived radionuclides underwent radioactive decay. In the early 1980s, discharges of MAC were suspended and it was retained in storage tanks, pending the construction of a plant to remove the radionuclides of greatest radiological concern (these did not include technetium- 99). The Enhanced Actinide Removal Plant started operation in 1994 and began to clear the backlog of stored waste MAC, as well as current arisings from Magnox reprocessing. As a consequence technetium-99 was once more discharged to sea. Subsequently, concentrations of this radionuclide in the marine environment increased. In particular, there was a significant increase in the concentration of technetium-99 in lobster in the Irish Sea. An increase in technetium-99 has also been detected at locations far distant from Sellafield, e.g. in Scandinavian coastal waters, albeit at very low concentrations. This dispersal of technetium- 99 throughout the Irish Sea and further afield has therefore caused concern, although the radiological impact is low. This paper examines the nature and source of the technetium-99 in sea discharges at Sellafield and the levels of past and current discharges as well as their impact. It goes on to describe the Environment Agency's recent proposals on the future regulation of technetium-99 discharges and how these should lead to substantial reductions in not only technetium-99 discharges, but also of other radionuclides such as caesium-137 and strontium-90. (author)

  19. Work in progress. Gastrointestinal ulcerations: detection using a technetium-99m-labeled ulcer-avid agent

    International Nuclear Information System (INIS)

    Vasquez, T.E.; Bridges, R.L.; Braunstein, P.; Jansholt, A.L.; Meshkinpour, H.

    1983-01-01

    Technetium-99m-labeled sucralfate, an ulcer-avid material, was shown in preliminary animal and human studies to be stable in vivo with good sensitivity. Eight experimentally produced discrete gastric ulcers in three rabbits were visualized using this material. Of seven human studies, four studies were true-positive and three were true-negative. It is suggested that Tc-99m-labeled sucralfate may prove to have significant clinical advantages for the evaluation of gastrointestinal ulcer disease and other diseases that are associated with loss of mucosal integrity. The method for labeling sucralfate with Tc-99m was developed by the authors

  20. Ultrasonic features and radionuclide correlation in liver cell adenoma and focal nodular hyperplasia. [/sub 99m/Tc-sulfur colloid; /sup 131/I-rose bengal; /sup 67/Ga-citrate

    Energy Technology Data Exchange (ETDEWEB)

    Sandler, M.A.; Petrocelli, R.D.; Marks, D.S.; Lopez, R.

    1980-05-01

    Ultrasonic features of three cases of liver cell adenoma (LCA) and two cases of focal nodular hyperplasia (FNH) are presented. These tumors have similar sonographic appearances presenting either as solid masses or containing sonolucent areas due to hemorrhage or necrosis. Although these ultrasonic features in patients wth an area of decreased activity on /sup 99m/Tc-sulfur colloid (Tc-SC) liver scans are not specific for LCA or FNH, such findings in the appropriate clinical setting are suggestive of these lesions. The combination of a solid mass on ultrasonography and a normal Tc-SC radioisotope liver study may be relatively specific for uncomplicated FNH.

  1. Clinical evaluation of technetium-99m infecton for the localisation of bacterial infection

    International Nuclear Information System (INIS)

    Britton, K.E.; Vinjamuri, S.; Hall, A.V.; Solanki, K.; Siraj, Q.H.; Bomanji, J.; Das, S.

    1997-01-01

    The aim of the study was to distinguish infection from inflammation in patients with suspected infection using technetium-99m Infecton. Ninety-nine patients (102 studies) referred for infection evaluation underwent imaging with 400 MBq 99m Tc-Infecton at 1 and 4 h. Most patients had appropriate microbiological tests and about half (56) had radiolabelled white cell scans as well. No adverse effects were noted in any patient. The clinical efficacy of 99m Tc-Infecton depended in part on whether imaging was undertaken during antibiotic therapy for infection or not. In consultation with the microbiologist, 5-14 days of appropriate and successful antibiotic therapy was considered adequate to classify some results as true-negatives. The figures for sensitivity and specificity of 99m Tc-Infecton for active or unsuccessfully treated infection were 83% and 91% respectively. It is concluded that 99m Tc-Infecton imaging contributed to the differential diagnosis of inflammation. It is being used as the first imaging modality when bacterial infection is suspected. (orig.). With 2 figs., 1 tab

  2. Radiation dose calculations for orally administered radio-pharmaceuticals in upper gastrointestinal disease

    International Nuclear Information System (INIS)

    Wu, R.K.; Malmud, L.S.; Knight, L.C.; Siegel, J.A.; Stern, H.; Zelac, R.

    1983-01-01

    Radiation burden estimates for upper gastrointestinal function studies employing the following orally administered radiopharmaceuticals are reported. Technetium 99m sulfur colloid (Tc-99m-SC) in water, Indium-111-DTPA in water, Tc-99m-DTPA in water, Indium-113m DTPA in water, Tc-99m Ovalbumin, Tc-99m sulfur colloid in a cooked egg, Tc-99m sulfur colloid in vivo labeled chicken liver, and Indium-111 colloid in vivo labeled chicken liver. Orally administered radiopharmaceuticals for upper gastrointestinal studies afford clinician and investigator valuable clinical and physiologic information not previously obtainable using other techniques. The radiation burden to the patient from single or sequential studies is acceptable in comparison to fluoroscopy which results in approximately 5000 millirem per minute of exposure. The variety of preparations listed above should make these types of studies available in any routinely equipped nuclear medicine radiopharmacy laboratory

  3. 99mTc-stannous colloid white cell scintigraphy in childhood inflammatory bowel disease.

    Science.gov (United States)

    Peacock, Kenneth; Porn, Ute; Howman-Giles, Robert; O'Loughlin, Edward; Uren, Roger; Gaskin, Kevin; Dorney, Stuart; Kamath, Ramanand

    2004-02-01

    99mTc-Labeled white cell scintigraphy (WCS) has been used for the investigation of inflammatory bowel disease (IBD) in adults, but data on children are limited. The most common agent used is (99m) Tc-hexamethylpropyleneamine oxime (HMPAO); however, this agent has limitations. In a retrospective study, we assessed the use of (99m)Tc-stannous colloid WCS for the initial evaluation of children with suspected IBD. Diagnostic, endoscopic, and contrast radiography results were retrospectively collected from the medical records. Two experienced nuclear physicians unaware of the patient data interpreted the WCS results, with agreement reached by consensus. Statistical analysis was performed on the ability of WCS to detect active disease and localize it topographically and on a comparison of diagnostic methods, using a combination of clinical features and endoscopy as the reference standard. Between 1996 and 1999, 64 patients (35 male and 29 female; mean age, 12.5 y; age range, 2-19 y) had WCS performed, with IBD subsequently diagnosed in 34 patients. (99m)Tc-Stannous colloid WCS had an 88% sensitivity, 90% specificity, and 8.8 likelihood ratio for initial investigation of IBD. Agreement was poor for topographic localization of disease. Small-bowel series had a 75% sensitivity, 50% specificity, and 1.5 likelihood ratio for detecting endoscopic disease of the terminal ileum and proximal colon. Our results confirm that WCS is a useful imaging technique for the initial evaluation of patients with suspected IBD. (99m)Tc-Stannous colloid had results at least comparable to those of other WCS agents, and in children, (99m)Tc-stannous colloid WCS should be preferred in view of lower cost, shorter preparation time, and the smaller blood volumes required.

  4. Renal handling of technetium-99m DMSA in rats with proximal tubular dysfunction

    International Nuclear Information System (INIS)

    Provoost, A.P.; Van Aken, M.

    1985-01-01

    The renal handling of technetium-/sup 99m/ dimercaptosuccinic acid ([/sup 99m/Tc]DMSA) was studied in rats before and after treatment with Na-maleate (2 mmol/kg i.v.). In the control period, when measured 2 hr after the intravenous injection of [/sup 99m/Tc]DMSA, 39.9% of the injected dose was in the kidneys and 14.6% was in the bladder. After Na-maleate treatment, only 6.4% of the injected dose of [/sup 99m/Tc]DMSA was retained in the kidneys while 37.9% was found in the bladder. Subsequent studies revealed that Na-maleate produced a fall in the glomerular filtration rate, the effective renal plasma flow, and a generalized proximal tubular dysfunction. The latter was characterized by polyuria and an increased excretion of glucose, protein, albumin, calcium, and inorganic phosphate. It was concluded that proximal tubular dysfunction markedly alters the renal handling of [/sup 99m/Tc]DMSA. Whether this augmented urinary excretion is due to an inhibition of reabsorption or an enhanced cellular efflux of [/sup 99m/Tc]DMSA remains to be answered

  5. Current status of Tc-99m production in Thailand

    International Nuclear Information System (INIS)

    Charoen, Sakda

    2003-01-01

    Technetium-99m is the workhorse of nuclear medicine and currently accounts for over 80% of all in vivo diagnostic procedures. In Thailand, Office of Atomic Energy for Peace (OAEP) had experiences in production of Technetium-99m by solvent extraction process and alternative technology for Technetium-99m generator based on zirconium molybdate and titanium molybdate gel generators were also studied. The paper describes past experiences and future plan of Technetium-99m production in Thailand. (author)

  6. Technetium-99m scintimammography in the diagnosis of malignant breast tumors

    Directory of Open Access Journals (Sweden)

    Jauković Ljiljana

    2004-01-01

    Full Text Available Background. Technetium-99m (99mTc tetrofosmin scintigraphy is a new imaging method for the diagnosis of various malignancies, such as lung, thyroid, and most frequently breast neoplasms. The aim of this study was to evaluate the diagnostic reliability of 99mTc-Tetrofosmin breast scintigraphy in the detection of malignant breast disease. Methods. 99mTc -Tetrofosmin scintimammography (SMM was performed in 28 patients with 30 breast lesions suspicious for malignancy. Standard mammography (MM was also done. After surgery, the results of SMM and MM were compared to definitive histopathological findings as the "gold standard". After intravenous injection of radiotracer, SMM was performed in prone and supine views of the thorax, using large field-of-view Gamma camera. Results. The results of SMM were interpreted visually and semiquantitatively, and evaluated as positive or negative. Sensitivity, specificity and accuracy, positive (PPV and negative predictive value (NPV were obtained in relation to histopathology. After comparing the results of SMM and MM, SMM was proved more sensitive (95% for SMM vs. 80% for MM, while the specificity of both methods was similar. Conclusion. The results of this study indicate that the contribution of SMM as a nuclear medicine procedure has its place in the diagnostic protocol for patients suspected of malignant breast cancer.

  7. Contribution of technetium 99m-labelled pyrophosphate bone scintigraphy in infectious spondylodiscitis

    International Nuclear Information System (INIS)

    Capdepont, M.-T.

    1976-01-01

    This work examines the contribution of technetium 99m(sup(99m)Tc)-labelled pyrophosphate bone scintigraphy in infectious spondylodiscitis and attempts to define its importance in the diagnosis of lesions and their subsequent supervision in patients under treatment. 5 to 15 millicuries of sup(99m)Tc-labelled pyrophosphates are injected intraveinously. Bone uptake is strong and durable; 1.3% of the injected activity is found in the blood by the fifth hour. The skeleton may be explored: - either one segment at a tome with a scintillation camera, - or all at once and more quickly with a whole-body device taking front and black exposures. Bone scintigraphy appears as a basic technique in the study of infectious spondylodiscitis. Moreover the use of increasingly efficient equipment, the quantification of results and perhaps the development of new tracers augur well for a technique which is already acknowledged to be of fundamental interest [fr

  8. Preparation of crotalus venom radiolabeled with technetium99m as a tool for biodistribution study

    International Nuclear Information System (INIS)

    Pujatti, Priscilla Brunelli; Santos, Raquel Gouvea dos; Simal, Carlos Jorge Rodrigues

    2005-01-01

    Technetium- 99m ( 99m Tc) has been the radionuclide of choice for nuclear medicine procedures and experimental research. Because of its optimal nuclear properties, 99m Tc is suitable for high efficiency detection with the advantage of reduced radiological waste. Crotalus venom (CV) has been shown to reduce tumors in clinical studies and tissue distribution studies are very important for clinical use. The goal of this work was to obtain CV labeled with 99m Tc which preserves its biological activity. After labeling, biological activity was assessed by hemolytic activity evaluation. Labeled and crude venom caused indirect hemolysis provided that the incubation medium contained an exogenous source of lecithin. High yield radiolabeled-CV was obtained and biological activity was preserved. The results suggest that 99m Tc-CV can be a useful tool for biodistribution studies. (author)

  9. Neutrophil labeling with [{sup 99m}Tc]-technetium stannous colloid is complement receptor 3-mediated and increases the neutrophil priming response to lipopolysaccharide

    Energy Technology Data Exchange (ETDEWEB)

    Gallagher, Hayley [School of Veterinary and Biomedical Sciences, James Cook University, Townsville, Queensland 4811 (Australia); Ramsay, Stuart C. [School of Medicine, James Cook University, Townsville, Queensland (Australia) and Townsville Nuclear Medicine, Mater Hospital, Townsville, Queensland 4812 (Australia)]. E-mail: stuart.ramsey@jcu.edu.au; Barnes, Jodie [School of Veterinary and Biomedical Sciences, James Cook University, Townsville, Queensland 4811 (Australia); Maggs, Jacqueline [Department of Nuclear Medicine, Townsville Hospital, Townsville, Queensland 4814 (Australia); Cassidy, Nathan [Townsville Nuclear Medicine, Mater Hospital, Townsville, Queensland 4812 (Australia); Ketheesan, Natkunam [School of Veterinary and Biomedical Sciences, James Cook University, Townsville, Queensland 4811 (Australia); School of Medicine, James Cook University, Townsville, Queensland (Australia)

    2006-04-15

    Introduction: [{sup 99m}Tc]-technetium stannous colloid (TcSnC)-labeled white cells are used to image inflammation. Neutrophil labeling with TcSnC is probably phagocytic, but the phagocytic receptor involved is not known. We hypothesised that complement receptor 3 (CR3) plays a key role. Phagocytic labeling could theoretically result in neutrophil activation or priming, affecting the behaviour of labeled cells. Fluorescence-activated cell sorter (FACS) analysis side scatter measurements can assess neutrophil activation and priming. Methods: We tested whether TcSnC neutrophil labeling is CR3-mediated by assessing if neutrophil uptake of TcSnC was inhibited by a monoclonal antibody (mAb) directed at the CD11b component of CR3. We tested if TcSnC-labeled neutrophils show altered activation or priming status, comparing FACS side scatter in labeled and unlabeled neutrophils and examining the effect of lipopolysaccharide (LPS), a known priming agent. Results: Anti-CD11b mAb reduced neutrophil uptake of TcSnC in a dose-dependent fashion. Labeled neutrophils did not show significantly increased side scatter compared to controls. LPS significantly increased side scatter in control cells and labeled neutrophils. However, the increase was significantly greater in labeled neutrophils than unlabeled cells. Conclusions: Neutrophil labeling with TcSnC is related to the function of CR3, a receptor which plays a central role in phagocytosis. TcSnC labeling did not significantly activate or prime neutrophils. However, labeled neutrophils showed a greater priming response to LPS. This could result in labeled neutrophils demonstrating increased adhesion on activated endothelium at sites of infection.

  10. Formamidine sulfinic acid as reducing agent in technetium-99m rhenium sulfide labelling

    Energy Technology Data Exchange (ETDEWEB)

    Neves, M; Patricio, L [Laboratorio Nacional de Engenharia e Technologia Industrial, Sacavem (Portugal). Dept. de Radioisotopes; Ferronha, H [Laboratorio Nacional de Investigacao Veterinaria, Lisboa (Portugal)

    1989-08-01

    Labelling kinetic studies, radiochemical characterization and particle size evaluation of {sup 99m}Tc rhenium sulfide colloid using formamidine sulfinic acid as reducing agent are described. Comparison with the same colloid which makes use of Sn-sodium pyrophosphate complex as reducing agent showed higher labelling yields, simplification of labelling procedure and a longer shelf life when formamidine sulfinic acid was used. (author) 15 refs.; 7 figs.

  11. Quantification of ocular inflammation with technetium-99m glucoheptonate

    International Nuclear Information System (INIS)

    Roizenblatt, J.; Caldeira, J.A.F.; Buchpiguel, C.A.; Meneguetti, J.C.; Camargo, E.E.; Sao Paulo Univ., SP

    1991-01-01

    Histological and morphometric evaluation of ocular inflammation is difficult, particularly when there is extensive ocular involvement with abscess formation and necrosis. A quantitative imaging procedure applicable to humans would be important clinically. To establish such a procedure, turpentine-induced ocular inflammation was obtained by subconjunctival injection in the right eye of 55 rabbits. The left eye was used as control and injected with a volume of saline equal to the volume of turpentine in the right eye. Volumes of turpentine or saline were 0.02, 0.04, 0.06, 0.2 and 0.6 ml, and the rabbits were divided into groups 1-5, according to these volumes. Imaging was performed 48 h after turpentine injection and 6 h after intravenous injection of 10 mCi of technetium 99m glucoheptonate ( 99m Tc-GH). An inflammatory reaction index (IRI), defined as the ratio of counts of the right eye divided by counts of the left eye, was used. IRIs were proportional to the degree of inflammation and allowed the distinction of 3 subgroups: One represented by group 4, one by group 5 and one by groups 1, 2 and 3. This method of quantification of ocular inflammatory processes using 99m Tc-GH is original, rapid, non-invasive, reproducible and safe, although unable to differentiate inflammatory processes caused by doses of turpentine which are very small and close to each other. It is conceivable that its application to humans will bring new insight into the ocular inflammatory process and response to therapy. (orig.)

  12. Obtention of scintillography images by low density lipoproteins labelled with technetium 99

    International Nuclear Information System (INIS)

    Silva, S.; Coelho, I.; Zanardo, E.; Pileggi, F.; Meneguethi, C.; Maranhao, R.C.

    1992-01-01

    The low density lipoproteins carry the most part of the cholesterol in the blood plasma. These lipoproteins are labelled with technetium-99-m and have been used for obtaining images in nuclear medicine. The introduction of this technique is presented, aiming futures clinical uses. Scintillographic images are obtained 25 minutes and 24 hours after the injection of 3 m Ci of low density lipoproteins - technetium-99 m in rabbits. (C.G.C.)

  13. Technetium-99m-labeled recombinant tissue plasminogen activator for the imaging of emboli in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Akihiro; Itoh, Kazuo; Tsukamoto, Eriko; Furudate, Masayori; Kamiyama, Hiroyasu; Abe, Hiroshi [Hokkaido Univ., Sapporo (Japan). School of Medicine

    1993-07-01

    Tissue-type plasminogen activator (t-PA) effectively lyses activate thrombus by direct action. Recombinant t-PA (rt-PA) was labeled with technetium-99m ([sup 99m]Tc) to investigate the in vivo binding to fibrin clots in a feline cerebral embolism model created by insertion of an artificial fibrin clot within the carotid artery. [sup 99m]Tc-rt-PA administered intravenously provided clearer imaging of clots after priming with cold rt-PA, with uptake peaking 5-10 minutes after the injection. [sup 99m]Tc-labeled human serum albumin was not retained at clot sites. Systemically administered [sup 99m]Tc-rt-PA binds to fibrin clots within carotid arteries in our feline model. Our results suggest that the interaction of intrinsic plasminogen activator inhibitors with extrinsically administered rt-PA may regulate the demonstration of a clot, although the precise mechanism is unclear. (author).

  14. Technetium-99m labeling and fibronectin binding ability of Corynebacterium diphtheriae

    International Nuclear Information System (INIS)

    Souza, S.M.S.; Nagao, P.E.; Bernardo-Filho, M.; Pereira, G.A.; Napoleao, F.; Andrade, A.F.B.; Hirata Junior, R.; Mattos-Guaraldi, A.L.

    2004-01-01

    The use of radionuclides has permitted advances in areas of clinical and scientific knowledge. Several molecules and cells have been labelled with Technetium-99m ( 99m Tc). The stannous chloride (SnCl 2 ) has a significant influence on the labeling and stability of 99m Tc radiotracers. The frequent risk of diphtheria epidemics has intensified interest in the virulence factors of Corynebacterium diphtheriae. Although studies have looked at potential adhesins including haemagglutinins and exposed sugar residues, the molecular basis of mechanisms of adherence remains unclear. Adherence of pathogens to mammalian tissues may be mediated by fibronectin (FN) found in body fluids, matrix of connective tissues, and cell surfaces. In the present study we evaluated the binding ability to human plasma FN by 99m Tc labeled-C.diphtheriae. Due to adverse effects of stannous ions, microorganisms were submitted to survival and filamentation induction assays. Data showed a dose dependent susceptibility to SnCl 2 bactericidal effects. Cell filamentation was observed for concentrations of SnCl 2 > 110 μg/ml. Adherence levels of 99m Tc labelled 241strain to coverslips coated with 20 μg/ml FN were higher (P = 0.0037) than coated with bovine serum albumin. FN binding by the sucrose fermenting 241 C. diphtheriae strain (8.9% + 2.6) was significantly lower (P=0.0139) than Staphylococcus aureus Cowan I strain (34.1% ± 1.2). Therefore, bacterial 99m Tc labeling represents an additional tool that may contribute to the comprehension of C. diphtheriae interactions with host receptors such as FN that act as biological organizers by holding bacterial cells in position and guiding their migration. (author)

  15. Technetium-99m methylene diphosphonate scintimammography for evaluation of palpable breast masses

    International Nuclear Information System (INIS)

    Shah, S.; Khan, M.M.; Khan, A.U.; Khan, S.M.; Khan, A.A.

    2002-01-01

    Objective:To evaluate technetium-99m methylene diphosphonate (/sup 99m/Tc-MDP) as a noninvasive tumor-localizing agent in patients with palpable breast masses and to differentiate malignant from benign breast lesions. Design: It was an observational and experimental study. Place and Duration of Study: the study was conducted at the Institute of Radiotherapy and Nuclear Medicine (IRNUM), Peshawar during a six-month period (June to November, 1995). Subjects and Methods: 99m Tc-MDP scintimammography (SMM) was performed in thirty patients with palpable breast masses (Group A). Ten patients with no palpable breast abnormality (Group B) also underwent /sup 99m/Tc-MDP breast study; they served as controls. Upright anterior, lateral and oblique lateral images of the breasts were acquired 10-30 minutes after intravenous injection of 740 MBq of /sup 99m/Tc-MDP. This was performed during routine bone scanning. SMM was followed by surgical and /or needle biopsy. Results: breast cancer was histologically diagnosed in twenty two (73%), and benign disease found in eight patients (27%). Of the twenty two breast carcinomas, twenty (91%) were detected using /sup 99m/Tc-MDP SMM, while no uptake was seen in two (9%). Of the eight patients with pathologically proven benign breast lesions, seven (88%) either did not show any uptake or showed faint bilateral accumulation. Focal /sup 99m/Tc-MDP uptake was observed in one fibroadenoma. Conclusion: The study showed that SMM with /sup 99m/Tc-MDP is positive in a high percentage of patients with carcinoma of the breast and may differentiate malignant from benign masses. (author)

  16. Intercellular Uptake of Technetium-99m Pertechnetate by Different Types of Cell Lines

    International Nuclear Information System (INIS)

    Safri Zainal Abidin; Raizulnasuha Abdul Rashid; Muhammad Afiq Khairil Anuar; Wan Nordiana A Abd Rahman

    2015-01-01

    The purpose of this study is to determine the technetium-99m pertechnetate ( 99m TcO 4 ) intercellular uptake by different types of cell lines. HeLa, human fetal osteoblast (hFOB), glial and glioma cell lines grown in 6-wells culture plates were incubated with 99m TcO 4 of activity of 200, 400, 600, 800 and 1000 μCi for 30 minutes at 37 degree Celsius and 5 % CO 2 humidified atmosphere. After incubation, the cells were washed 3 times with phosphate buffer saline to remove the extracellular traces of 99m TcO 4 . Measurement of the intercellular 99m TcO 4 into the cells was calculated. The intercellular uptake of 99m TcO 4 was found to be inversely correlate to the radioactivity. HHeLa cell shows the highest uptake followed by hFOB, glial and glioma cell lines. Comparison of uptake between normal and cancer cells present indistinguishable results. The findings of this study suggest that the intercellular uptake of 99m TcO 4 is highly dependent on the type of cells despite no significant different of uptake was found between normal and cancer cell lines. The level of radioactivity is also an important determinant factor that influence the uptake of 99m TcO 4 into the cell. The study will be the first precedent toward understanding the cellular characteristics and pharmacokinetic of non-invasive imaging tracer for future molecular imaging and therapy. (author)

  17. /sup 99m/Tc-labeled solid-phase meal: a quantitative clinical measurement of human gastric emptying

    Energy Technology Data Exchange (ETDEWEB)

    Martin, J.L.; Beck, W.J.; McDonald, A.P.; Carlson, G.M.; Mathias, J.R.

    1983-08-01

    A solid-phase meal labeled with /sup 99m/Tc-sulfur colloid provides an improved clinical test for the quantitative evaluation of human gastric emptying. We studied 12 healthy male controls and five male patients with known gastric stasis secondary to a vagotomy and drainage procedure. All subjects were fasted for 8 hours before the study, and each consumed an unbuttered biscuit and a poached egg white containing 1 mCi of /sup 99m/Tc-sulfur colloid. For 2 hours, 60-second counts were measured every 10 minutes by a Pho Gamma III scintillation camera. The t/sup 1///sup 2/ for control subjects was 60 minutes, at which time patients with gastric stasis had retained 98% of the test meal. At 120 minutes, control subjects and patients with gastric stasis had 4.7% and 89%, respectively, of the meal remaining in the stomach. The solid-phase test meal labeled with /sup 99m/Tc-sulfur colloid is easy to perform and can be used clinically to quantitatively measure gastric emptying in humans. This test can discriminate between control subjects and patients with known gastric stasis.

  18. /sup 99m/Tc-labeled solid-phase meal: a quantitative clinical measurement of human gastric emptying

    International Nuclear Information System (INIS)

    Martin, J.L.; Beck, W.J.; McDonald, A.P.; Carlson, G.M.; Mathias, J.R.

    1983-01-01

    A solid-phase meal labeled with /sup 99m/Tc-sulfur colloid provides an improved clinical test for the quantitative evaluation of human gastric emptying. We studied 12 healthy male controls and five male patients with known gastric stasis secondary to a vagotomy and drainage procedure. All subjects were fasted for 8 hours before the study, and each consumed an unbuttered biscuit and a poached egg white containing 1 mCi of /sup 99m/Tc-sulfur colloid. For 2 hours, 60-second counts were measured every 10 minutes by a Pho Gamma III scintillation camera. The t 1 / 2 for control subjects was 60 minutes, at which time patients with gastric stasis had retained 98% of the test meal. At 120 minutes, control subjects and patients with gastric stasis had 4.7% and 89%, respectively, of the meal remaining in the stomach. The solid-phase test meal labeled with /sup 99m/Tc-sulfur colloid is easy to perform and can be used clinically to quantitatively measure gastric emptying in humans. This test can discriminate between control subjects and patients with known gastric stasis

  19. Comparison of four technetium-99m radiopharmaceuticals for detection and localization of gastrointestinal bleeding in a sheep model

    International Nuclear Information System (INIS)

    Owunwanne, A.; Al-Wafai, I.; Vallgren, S.; Sadek, S.; Abdel-Dayem, H.M.; Yacoub, T.

    1988-01-01

    Four Tc-99 radiopharmaceuticals, Tc-99m sulphur colloid, Tc-99m red blood cells (RBCs), Tc-99m mercaptoacetyltriglycine (MAG3), and Tc-99m DTPA, were studied in an experimental animal model for detection and localization of gastrointestinal (GI) bleeding site in both the upper and lower abdomen. With Tc-99m sulphur colloid and Tc-99m RBCs, it was possible to detect and localize the GI bleeding site in the lower abdomen. With Tc-99m MAG3, it was possible to visualize the bleeding site in both the upper and lower abdomen. However, Tc-99m MAG3 is partially excreted by the liver into the bile, hence it will be difficult to use Tc-99m MAG3 to localize the GI bleeding site in the lower abdomen. With Tc-99m DTPA, it was possible to detect and localize the GI bleeding site simultaneously in both upper and lower abdomen. The overall background radioactivity was reduced considerably by diuresis with frusemide and catheterization of the urinary bladder

  20. evaluation of some technetium-99m fluoroquinolones complexes as imaging agents for bacterial inflammatory lesions

    International Nuclear Information System (INIS)

    Abdel-Kawy, O.A.A.

    2007-01-01

    in this study, the labeling method of ciprofloxacin and levofloxacin with technetium-99m and their biological evaluation in man-induced inflammation models were described . in -vitro microbiological evaluation of both complexes was also performed in order to investigate the effect of labeling on the activity and spectrum of both antibiotics. all the gathered biological data support the usefulness of 99m Tc-fluoroquinolones as infection imaging agents that could discriminate between infections and sterile inflammations. the freeze-dried form of levofloxacin kits was prepared and found to meet all the radiochemical and biological tests

  1. Comparison of liver scintigraphy with sup(99m)Tc-phytate and 198Au-colloid in diffuse hepatic disorders

    International Nuclear Information System (INIS)

    Kamoi, Itsuma; Watanabe, Katsushi; Kawahira, Kenjiro; Nakayama, Chikashi; Higashi, Yoshitaka

    1975-01-01

    sup(99m)Tc-phytate was evaluated as a liver scintigraphic radiopharmaceutical, and the results were compared with those of 198 Au-colloid. Both radionuclides were used on the same day in 55 cases of diffuse hepatic disorders. In 52 of the 55 cases, excellent liver images were obtained with sup(99m)Tc-phytate. Compared with 198 Au-colloid, sup(99m)Tc-phytate was more highly concentrated in the spleen and bone marrow and with higher background radioactivity, although their distributions generally coincided. The known diagnostic criteria for liver scintigraphy with 198 Au-colloid in diffuse hepatic disorders were proven applicable to sup(99m)Tc-phytate. (auth.)

  2. Technetium-99m-labeled N-(2,6-dimethylphenylcarbamoylmethyl) iminodiacetic acid (/sup 99m/Tc HIDA): a new radiopharmaceutical for hepatobiliary imaging studies. [/sup 14/C, /sup 113/Sn

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, J.; Cooper, M.; Loberg, M.; Harvey, E.; Sikorski, S.

    1977-10-01

    An easily formulated, stable kit preparation of technetium-99m HIDA, suitable for use in humans, was developed and tested in mice and dogs. The tracer was cleared rapidly from the blood and excreted predominantly by the liver in both species. In dogs, the hepatobiliary clearance of Tc-99m HIDA was significantly greater than that of C-14 HIDA and Sn-113 HIDA. The LD/sub 50/ for HIDA in mice, 168 mg/kg, exceeded the average human dose by a factor of 1000 on a per-weight basis. Blood clearance curves for Tc-99m HIDA in 12 normal subjects were biexponential with half-times of 4.6 +- 1.0 min and 31.5 +- 7.0 min, and cumulative 90-min urine samples contained 14.2 +- 1.8% of the injected dose. Images in normal subjects and nonjaundiced patients showed rapid concentration of tracer by the liver and activity was present within the biliary system in 10 to 20 min. In jaundiced patients, the tracer blood clearance was delayed and urinary excretion increased, but intestinal activity, indicating biliary patency, was imaged in those patients without complete focal obstruction of the common duct. Technetium-99m HIDA is a nontoxic radiopharmaceutical useful for clinical evaluation of hepatobiliary disorders in humans.

  3. Bone-seeking /sup 99m/Tc complex

    International Nuclear Information System (INIS)

    Subramanian, G.; McAfee, J.G.

    1977-01-01

    A bone-seeking, technetium-99m-tin-phosphonate complex effective as a skeletal-imaging agent has been found particularly useful for diagnostic purposes. Skeletal tissue concentrations or technetium-99m obtained with the complex compare favorably to other bone-seeking radionuclides

  4. Technical considerations in gastric ulcer localization using technetium-99m sucralfate

    International Nuclear Information System (INIS)

    Garrett, S.G.; Wcislo, W.J.

    1985-01-01

    After the completion and evaluation of 17 patients studies using technetium-99m-labeled sucralfate for the detection of ulcerated areas, the authors felt that the technical aspects of the studies should be evaluated. The factors for evaluation are: the time the patient is kept fasting; the time the patient is being imaged and rotated for various anatomic views; the technologist time and camera time that are involved in one study; and the cost factor of the testing procedure. Based on the findings of their small sample of patients, the sensitivity of the test is uncertain

  5. Technical considerations in gastric ulcer localization using technetium-99m sucralfate

    Energy Technology Data Exchange (ETDEWEB)

    Garrett, S.G.; Wcislo, W.J.

    1985-09-01

    After the completion and evaluation of 17 patients studies using technetium-99m-labeled sucralfate for the detection of ulcerated areas, the authors felt that the technical aspects of the studies should be evaluated. The factors for evaluation are: the time the patient is kept fasting; the time the patient is being imaged and rotated for various anatomic views; the technologist time and camera time that are involved in one study; and the cost factor of the testing procedure. Based on the findings of their small sample of patients, the sensitivity of the test is uncertain.

  6. Increased technetium-99 m hydroxy diphosphonate soft tissue uptake on bone scintigraphy in chronic kidney disease patients with secondary hyperparathyroidism

    DEFF Research Database (Denmark)

    Enevoldsen, Lotte Hahn; Heaf, James Goya; Højgaard, Liselotte

    2017-01-01

    In bone scan patients with dialysis-treated chronic kidney disease (CKD) and hyperparathyroidism, soft tissue accumulation of technetium-99 m hydroxy/methylene diphosphonate (Tc-99 m-HDP/MDP) has been reported primarily in case reports and usually explained by hypercalcaemia and/or hyperphosphata......In bone scan patients with dialysis-treated chronic kidney disease (CKD) and hyperparathyroidism, soft tissue accumulation of technetium-99 m hydroxy/methylene diphosphonate (Tc-99 m-HDP/MDP) has been reported primarily in case reports and usually explained by hypercalcaemia and...... patients diagnosed with secondary hyperparathyroidism admitted for Tc-99 m-HDP bone scan. Baseline characteristics and mean concentrations of biochemical markers (including P-calcium and P-phosphate) taken 0-3 months prior to the bone scans were collected. Soft tissue uptake was detected on bone scans....../or hyperphosphataemia. As human vascular smooth muscle cells produce hydroxyapatite during cell culture with increased phosphate levels and as Tc-99 m-HDP/MDP primarily binds to hydroxyapatite, we hypothesized that soft tissue accumulation would be found in patients with hyperphosphataemia. We identified 63 CKD...

  7. Present status of Mo-99/Tc-99m generator in Thailand

    International Nuclear Information System (INIS)

    Khongpetch, Pranom

    2007-01-01

    Isotop Production Program, Office of Atoms for Peace had produced technetium-99m by MEK extraction of Mo-99 obtained from (n,γ) reaction in TRIGA Mark III reactor and supplied to nuclear medicine centers in Bangkok from 1980 to 1997. Because of the difficulty to meet the increased demand and limitation of reactor operation, the production of technetium-99m was stopped in 1997. Presently, there are 21 nuclear medicine centers with 25 SPECT, 7 gamma camera and 3 PET. All nuclear medicine centers are currently using imported Tc-99m generator. (author)

  8. Quantitative analysis of planar technetium-99m-sestamibi myocardial perfusion images using modified background subtraction

    International Nuclear Information System (INIS)

    Koster, K.; Wackers, F.J.; Mattera, J.A.; Fetterman, R.C.

    1990-01-01

    Standard interpolative background subtraction, as used for thallium-201 ( 201 Tl), may create artifacts when applied to planar technetium-99m-Sestamibi ( 99m Tc-Sestamibi) images, apparently because of the oversubtraction of relatively high extra-cardiac activity. A modified background subtraction algorithm was developed and compared to standard background subtraction in 16 patients who had both exercise-delayed 201 Tl and exercise-rest 99m Tc-Sestamibi imaging. Furthermore, a new normal data base was generated. Normal 99m Tc-Sestamibi distribution was slightly different compared to 201 Tl. Using standard background subtraction, mean defect reversibility was significantly underestimated by 99m Tc-Sestamibi compared to 201 Tl (2.8 +/- 4.9 versus -1.8 +/- 8.4, p less than 0.05). Using the modified background subtraction, mean defect reversibility on 201 Tl and 99m Tc-Sestamibi images was comparable (2.8 +/- 4.9 versus 1.7 +/- 5.2, p = NS). We conclude, that for quantification of 99m Tc-Sestamibi images a new normal data base, as well as a modification of the interpolative background subtraction method should be employed to obtain quantitative results comparable to those with 201 Tl

  9. Synthesis and biodistribution of nitrido technetium-99m radiopharmaceuticals with dithiophosphinate ligands: a class of brain imaging agents

    International Nuclear Information System (INIS)

    Bellande, Emmanuel; Comazzi, Veronique; Laine, Jacques; Lecayon, Michele; Pasqualini, Roberto; Duatti, Adriano; Hoffschir, Didier

    1995-01-01

    The symmetrical complexes [ 99m Tc][TcN(R 2 PS 2 ) 2 ] [R = CH 3 , CH 2 CH 3 , CH 2 CH 2 CH 3 , CH 2 (CH 3 ) 2 ], and the unsymmetrical complex [ 99m Tc][TcN(Me 2 PS 2 )(Et 2 PS 2 )] have been prepared, at tracer level, through a two-step procedure involving the preliminary formation of a prereduced technetium nitrido intermediate followed by substitution reaction onto this species by the appropriate dithiophosphinate ligand [R 2 PS 2 ]Na. The chemical identity of the resulting complexes have been established by comparison with the corresponding 99 Tc-analogs prepared, at macroscopic level, by reacting the complex [ 99 TcNCl 4 ] [n-Bu 4 N] (n-Bu = n-butyl) with an excess of ligand in methanol, and characterized by elemental analyses and spectroscopic techniques. The complexes are neutral and lipophilic, and possess a square pyramidal geometry, with an apical Tc N group and two dithiophosphinate ligands spanning the four positions on the basal plane through the four sulfur atoms of the >PS 2 group. In vitro studies showed that these radiopharmaceuticals are stable in solution and that their chemical identity was not altered after incubation with rat blood. Biodistribution studies have been carried out in rats and primates. The results demonstrate that these compounds are significantly retained into the brain of these animals for a prolonged time. Planar gamma camera images have been obtained in monkeys showing a good visualization of the cerebral region. However, the existence of persistent blood activity yields a brain/blood ratio lower than that observed with other 99m Tc-based brain perfusion imaging agents

  10. Effect of expression of P-glycoprotein on technetium-99m methoxyisobutylisonitrile single photon emission computed tomography of brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Shibata, Yasushi; Matsumura, Akira; Nose, Tadao [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine

    2002-08-01

    The expression of P-glycoprotein was investigated imunohistochemically in 26 brain tumor tissues and compared with the findings of technetium-99m methoxyisobutylisonitrile single photon emission computed tomography ({sup 99m}Tc-MIBI SPECT) to clarify the effect of P-glycoprotein on the diagnostic accuracy. P-glycoprotein labeling index of both tumor cells and vascular endothelial cells showed no clear relationship with the findings of {sup 99m}Tc-MIBI SPECT imaging. Expression of P-glycoprotein has no effect on the diagnostic accuracy of {sup 99m}Tc-MIBI SPECT. (author)

  11. An improved method for determination of technetium-99m half-life for the quality assurance procedures of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Abd Jalil Abd Hamid; Juhari Mohd Yusof; Zakaria Ibrahim; Wan Mohd Ferdaus Wan Ishak; Mohamad Hafiz Ahmad

    2009-01-01

    An improve method for identity tests of technetium-99m for the quality assurance procedures are presented. Computerized methods based on the least-squares of decay curve fitting for half-life estimation of technetium-99m was tested. Thus, least-squares method was employ as a decay curve fitting procedures in our software. Theoretical calculated half-life of technetium-99m for evaluation was performed for comparison. In Fig. 3 is shown, the decay curve fitting of a sample over one second counting time interval. The R2 value of the curve suggests that the time of the study was too short to obtain acceptable value. A similar measurement for another data set was done for a longer period of time and in Table 1 is shown a representative decay curve fitting. The value was found to be 6.006 hours with a discrepancy of -0.28% from the value taken from the literature. The value is in agreement with the literature for time interval greater than 2 seconds. The results obtained by this method show that the used of least-squares method for decay curve fitting are appropriate for routine identity tests. This confirmed that the least-squares method applied in our decay curve fitting software are remarkably improved and convenient for routine identity tests purposes. (Author)

  12. Synthesis, characterization and biodistribution of technetium complexes (99Tc/99mTc) with 2-amino-2-deoxy-D-hexose oximes

    International Nuclear Information System (INIS)

    Steinmetz, H.J.

    1993-05-01

    In the present work, the synthesis and isolation of isomeric complexes of technetium ( 99 Tc/ 99m Tc) with the 2-amino-2-deoxy-D-hexoses D-glucose aminoxime, D-galactose aminoxime and D-mannose aminoxime, the characterization of the complexes as 99 Tc compounds, and bio-distribution studies on the analogous 99m Tc complexes have been untertaken. As a first step, the free ligands were synthesized and identified using elemental analysis, infra-red and nuclear magnetic resonance spectroscopy and FAB mass spectroscopy. In the bio-distribution studies on the 99m Tc complexes of D-glucose aminoxime and of D-galactose aminoxime in NMRI mice, significant short-term accumulation of 99m Tc activity in heart muscle could be detected, which may be attributed to a biochemical transport mechanism. Uptake in the lungs and the liver was found, but a more significant uptake was observed in the kidneys, where the complexes were rapidly secreted in proportion to their concentration in the blood plasma. (orig./BBR) [de

  13. Abdominal-thoracic gamma-graphy with colloids in the hepatic hydrothorax

    International Nuclear Information System (INIS)

    Agostinho, C.; Sousa, C.; Pedroto, I.; Areias, J.; Pinho, C.; Amorim, I.

    1997-01-01

    Full text: The authors present two cases with refractory hydrothorax and the necessity of thoracentesis of repetition. In both cases, the study of the pleural liquid revealed to be a transudates, with mesothelial cells, macrophages, leukocytes and negative microbiologic examination. Abdomino-thoracic gammagraphy has been performed by injecting colloids labeled with Technetium-99m in the peritoneal cavity (left iliac fossa) under echography control, which confirmed the diagnostic hypothesis of hepatic hydrothorax for labeled activity in the thoracic cavity after 30 minutes. The importance of the confirmed diagnosis oriented the therapeutic program. The abdomino-thoracic gammagraphy using colloids labeled with Technetium-99m showed to be a simple and an important technique to diagnose the hepatic hydrothorax

  14. Radiolabeling small RNA with technetium-99m for visualizing cellular delivery and mouse biodistribution

    International Nuclear Information System (INIS)

    Liu Ning; Ding Hongliu; Vanderheyden, Jean-Luc; Zhu Zhihong; Zhang Yumin

    2007-01-01

    To develop a noninvasive direct method for the in vivo tracking of small interfering RNA (siRNA) used in RNA interference, two 18-nucleotide oligoribonucleotides were radiolabeled with technetium-99m ( 99m Tc-RNA). The ability of 99m Tc-RNA to track delivery was tested in cultured cells and living mice. The cellular delivery of 99m Tc-RNAs could be quantified by gamma counting and could be visualized by microautoradiography. Radiolabeled RNAs can be efficiently delivered into cells by reaching up to 3x10 5 molecules of small RNAs per cell. Moreover, RNAs were internalized with homogeneous distribution throughout the cytoplasm and nucleus. In tumor-bearing mice, whole-body images and biodistribution studies showed that 99m Tc-RNAs were delivered to almost all tissues after intravenous injection. The imaging of living animals allowed noninvasive and longitudinal monitoring of the in vivo delivery of these small RNAs. In conclusion, using 99m Tc radiolabeling, the delivery of small RNAs could be measured quantitatively in cultured cells and could be noninvasively visualized in living animals using a gamma camera. The results of this study could open up a new approach for measuring the in vivo delivery of small RNAs that might further facilitate the development of siRNAs as targeted therapies

  15. Corrosion and antifouling characteristics of technetium 99 in seawater

    International Nuclear Information System (INIS)

    Spitsyn, V.I.; Strekalov, P.V.; Balakhovskij, O.A.; Mikhajlovskij, Yu.N.

    1982-01-01

    The results are presented of studying the corrosive and antifouling properties of metallic technetium-99 in the Barents Sea and the Sea of Japan. Foil of 99 Tc glued on acrylic plastic served as a sample. High corrosion resistance and antifouling properties exhibited by 99 Tc in seawater point to favorable prospects of further studies aimed at development of new methods for protection against corrosion and fouling of metallic structures and parts with the use of technetium. The antifouling properties of technetium would evidently be used most efficiently when coating materials of high corrosion resistance to seawater (titanium, stainless steels, special alloys, etc.) with layers of technetium. The use of technetium for coating low-alloyed or carbon steels employed in seawater is yet problematic

  16. Assessment of hepatocyte and kupffer cell function using Tc-99m DISIDA/Tc-99m tin colloid in thioacetamide-induced liver injury

    International Nuclear Information System (INIS)

    Ahn, B. C.; Chun, K. A.; Lee, J.; Lee, K. B.

    1997-01-01

    Toxic liver injury is not unusual in clinical field and liver biopsy is one of the most accurate method to define the severity of liver injury. But occasionally, it is impossible to obtain liver tissue in patients with acute toxic liver injury. The aim of this study is to evaluate the possibility of liver scintigraphy with Tc-99m DISIDA or Tc-99m tin colloid as a non-invasive tool in predicting functional status of hepatocyte and Kupffer cell and severity of liver injury. Intraperitoneal injection of thioacetamide was performed to make acute liver injury in mice and rats, and liver status was assessed by pathologic specimen and scintigraphic methods. Scintigraphic evaluation were performed by biodistribution of Tc-99m DISIDA or Tc-99m tin colloid in thioacetamide-treated mice. Liver time-activity curves were generated. Comparison between histologic data and scintigraphic data was done with SAS program. Thioacetamide-treated mice demonstrated hepatocyte necrosis in histologic examination and low liver/blood uptake ratios in biodistribution studies using both radiotracers. Biodistribution study using Tc-99m tin colloid revealed increased lung radioactivity in thioacetamide-treated mice. Twenty-four hours after thioacetamide administration, thioacetamide-treated rats demonstrated maximal hepatocyte necrosis and inflammation in histologic finding and delayed maximal uptake time (Tmax) and prolonged half time (T 1/2 ) of liver time-activity curve in liver scintigraphy. Histologic results and scintigraphic data were well correlated, and these two scintigraphic parameters (Tmax T 1/2 ) seemed to be good predictors of histologic change of liver. These data showed that liver injury could be assessed by non-invasive scintigraphic study in rat and mouse. This experimental study might be used as a animal model to evaluate the liver protecting drugs, and this scintigraphic study could be applied to acute toxic hepatitis for assessment of liver status in men

  17. Monitoring of airborne contamination during the handling of technetium-99m and radioiodine

    International Nuclear Information System (INIS)

    Eadie, A.S.; Horton, P.W.; Hilditch, T.E.

    1980-01-01

    Measurements have been made using an air sampler to measure airborne radioactivity produced during the routine handling of large activities of technetium-99m, iodine-125 and iodine-131. The results indicate that 99 Tcsup(m) can be safely handled in environments without direct exhaust of the ventilated air but that 125 I and 131 I should always be handled in a ventilated environment such as a fume cupboard or a down-draught work-station of the total-exhaust type. Monitoring of thyroid uptake proves to be the most reliable means of monitoring airborne contamination by these radionuclides, but burdens and radiation doses for typical procedures are well within the maximum permissible limits of the Code of Practice for the Protection of Persons from Ionizing Radiation arising from Medical and Dental Use. (author)

  18. Preoperative parathyroid gland localization with technetium-99m sestamibi in secondary hyperparathyroidism

    International Nuclear Information System (INIS)

    Pons, F.; Vidal-Sicart, S.; Fuster, D.; Herranz, R.; Torregrosa, J.V.; Sabater, L.; Fernandez-Cruz, L.

    1997-01-01

    Technetium-99m sestamibi scintigraphy has become a valuable tool in locating parathyroid glands in patients with primary hyperparathyroidism. The aim of this study was to evaluate its usefulness in secondary hyperparathyroidism. Twenty patients were injected intravenously with 740 MBq of 99m Tc-sestamibi and images were obtained at 15 min and 2 h post injection. All patients underwent parathyroid ultrasonography (US) as well as bilateral surgical neck exploration and 64 parathyroid glands were removed. US revealed at least one enlarged gland in 15/20 patients (75%), while 99m Tc-sestamibi scintigraphy showed focal areas of increased uptake in at least one gland in 17/20 patients (85%). When imaging results for all glands were evaluated according to surgical results, sensitivity was 54% for parathyroid scintigraphy and 41% for US, and specificity was 89% for both imaging techniques. There was a discrepancy between the two imaging modalities in 28 glands (35%). The mean surgical weight of US-positive glands (1492±1436 mg) was significantly higher than that of US-negative glands (775±703 mg) (P 99m Tc-sestamibi scintigraphy are complementary imaging techniques in the preoperative localization of abnormal parathyroid glands in patients with secondary hyperparathyroidism. The limited sensitivity of the techniques means that patients will still require bilateral neck exploration; therefore routine preoperative parathyroid scanning in renal patients is not justified. (orig.)

  19. Synthesis, radiochromatography and biodistribution of Tc99m-hexakis-(methoxyisonitrile)-technetium(I) complexes

    International Nuclear Information System (INIS)

    Angelberger, P.; Zbiral, E.

    1987-09-01

    Following previous experience with Tc-99m-hexakis(t-butyl-isonitrile)-technetium(I) (Tc99m-tBiN) synthetic routes to the new ligands a) 1-methoxypropyl-2-isonitrile (MPiN) and b) 2-methoxy-2-methylpropyl-1-isonitrile(MiBiN) were developed via dehydration of the corresponding formamides. Formamide (a) was prepared from the available amine (a) while formamide (b) was synthesised by a difficult 5 step sequence starting from tert.2,2,2-trichlorobutanol. Product MPiN and MiBiN was purified by vacuum distillation and characterized by elemental analysis, IR- and NMR-spectra. A labeling method was developed based on earlier work with Tc99m-tBiN :the pure isonitrile ligand in ethanolic/aqueous solution was complexed at elevated temperature with reduced Tc-99m formed in situ with dithionite at alkaline pH. The whole reaction mixture was subjected to preparative HPLC leading to identification by UV-absorption and isolation of pure n.c.a. Tc99m-MPiN (A) and Tc99m-MiBiN (B) free of unreacted ligand. Work-up of the isolated peak resulted in an injectable product (overall radiochemical yield ∼80% within ∼40 min total preparation time) which was further controlled by TLC (radiochemical purity >97%, in vitro stability >6 hrs). Biodistribution in mice compared to identical data obtained with Tc99m-tBiN revealed somewhat higher heart uptake, slightly lower lung but significantly lower liver activity and renders these new Tc99m-compounds highly promising for myocardinal perfusion studies in man. 11 refs., 5 figs. (Author)

  20. The value and throughput of rest Thallium-201/stress Technetium -99m sestamibi dual-isotope myocardial SPECT.

    Science.gov (United States)

    Okudan, Berna; Smitherman, Thomas C

    2004-06-01

    Myocardial perfusion scintigraphy is an established method in cardiology for the diagnosis and evaluation of coronary artery disease (CAD). Thallium-201 and Tc-99m sestamibi myocardial perfusion imaging has been widely accepted as non-invasive diagnostic procedure for detection of CAD, risk stratification and myocardial viability assessment. But, standard Tl-201 redistribution and same day or 2-day rest/stress Tc-99m sestamibi protocols are time-consuming. Hence, the dual isotope rest thallium-201/stress technetium-99m sestamibi gated single-photon emission tomography protocol has gained increasing popularity for these applications. Combining the use of thallium-201 with technetium-99m agents permits optimal image resolution and simultaneous assessment of viability. Dual-isotope imaging may be separate or simultaneous acquisition set-up. The more rapid completion of these studies is appreciated as an advantage by patients, technologists, interpreting and referring physicians, nurses and hospital management. Simultaneous imaging has the potential advantages of precise pixel registration and artifacts, if present, are identical in both thallium and sestamibi, and require only one set of imaging. Also, there are some disadvantages of spillover of activity from the Tc-99m to the Tl-201 window. Fortunately, despite this problem it can be overcome. Separate acquisition dual isotope also has some disadvantages. Difference in defect resolution in attenuation and scatter between T-201 and Tc-99m sestamibi potentially results in interpretation problems. But, studies about cost-effectiveness of dual isotope imaging showed that some selective elimination of the rest studies may decrease the cost of the nuclear procedures and should be considered in the current care health system.

  1. Molybdenum-99/technetium-99M generators

    International Nuclear Information System (INIS)

    Morcos, N.A.; Bruno, G.A.; Haney, T.A.

    1981-01-01

    A 99 Mo/sup(99m)Tc generator is described which has an alumina support medium consisting of multiple beds of controlled pH and in which no bed has a pH value higher than the bed preceding it. It is claimed that by using this method low yield problems of such generators can be mitigated. (U.K.)

  2. Technetium-99m mercaptoacetyltriglycine clearance: reference values for infants and children

    Energy Technology Data Exchange (ETDEWEB)

    Schofer, O. [Department of Pediatrics, Johannes-Gutenberg University, Mainz (Germany); Koenig, G. [Department of Pediatrics, Johannes-Gutenberg University, Mainz (Germany); Bartels, U. [Department of Pediatrics, Johannes-Gutenberg University, Mainz (Germany); Bockisch, A. [Department of Nuclear Medicine, Johannes-Gutenberg University, Mainz (Germany); Piepenburg, R. [Department of Nuclear Medicine, Johannes-Gutenberg University, Mainz (Germany); Beetz, R. [Department of Pediatrics, Johannes-Gutenberg University, Mainz (Germany); Meyer, G. [Department of Nuclear Medicine, Ludwig Maximilians University, Munich (Germany); Hahn, K. [Department of Nuclear Medicine, Ludwig Maximilians University, Munich (Germany)

    1995-11-01

    Six hundred and thirty-nine clearance studies performed in children aged 7 days to 19 years utilizing technetium-99m mercaptoacetyltriglycine (MAG 3) were retrospectively analysed. Standardized conditions for the investigation included: parenteral hydration (60 ml/hxm{sup 2} body surface) in addition to normal oral fluid intake, weight-related dose of {sup 99m}Tc-MAG 3 (1 MBq/kg body weight, minimum 15 MBq) and calculation of clearance according to Bubeck et al. Of the 513 children, 169 included in this analysis could be classified as ``normal`` with regard to their renal function. Normal kidney function was judged by the following criteria: normal GFR for age, normal tubular function (absence of proteinuria and glucosuria), normal renal parenchyma (on ultrasonography, MAG 3 scan and intravenous pyelography), absence of significant obstruction and gross reflux (> grade I) no single kidney and no difference in split renal function > 20%. Results showed increasing MAG 3 clearance values for infants during the first months of life, reaching the normal range for older children and adults between 7 and 12 months. (orig.)

  3. Technetium-99m mercaptoacetyltriglycine clearance: reference values for infants and children

    International Nuclear Information System (INIS)

    Schofer, O.; Koenig, G.; Bartels, U.; Bockisch, A.; Piepenburg, R.; Beetz, R.; Meyer, G.; Hahn, K.

    1995-01-01

    Six hundred and thirty-nine clearance studies performed in children aged 7 days to 19 years utilizing technetium-99m mercaptoacetyltriglycine (MAG 3) were retrospectively analysed. Standardized conditions for the investigation included: parenteral hydration (60 ml/hxm 2 body surface) in addition to normal oral fluid intake, weight-related dose of 99m Tc-MAG 3 (1 MBq/kg body weight, minimum 15 MBq) and calculation of clearance according to Bubeck et al. Of the 513 children, 169 included in this analysis could be classified as ''normal'' with regard to their renal function. Normal kidney function was judged by the following criteria: normal GFR for age, normal tubular function (absence of proteinuria and glucosuria), normal renal parenchyma (on ultrasonography, MAG 3 scan and intravenous pyelography), absence of significant obstruction and gross reflux (> grade I) no single kidney and no difference in split renal function > 20%. Results showed increasing MAG 3 clearance values for infants during the first months of life, reaching the normal range for older children and adults between 7 and 12 months. (orig.)

  4. Generators of 99Mo-99mTc

    International Nuclear Information System (INIS)

    Robles, A.M.

    1994-01-01

    Between the radioisotopes family pairs we find the 99 Molibdenum - 99m technetium pairs. Such as isotope production,decay and chemical toxic, humid and dry generators,radiation protection handling practice and blinding had been sudied in this work.Tabs

  5. Technetium99m shortage: Practical solutions to manage lack of the radio-isotope in nuclear medicine departments

    International Nuclear Information System (INIS)

    Biechlin-Chassel, M.L.; Francois-Joubert, A.; Bolot, C.; Desruet, M.D.; Bourrel, F.; Pelegrin, M.; Couret, I.; Lao, S.; Quelven, I.

    2010-01-01

    Technetium 99m ( 99m Tc) shortage crisis regularly affect nuclear medicine activity and oblige the community to find solutions in order to perform most of the prescribed exams and avoid systematic substitutions by other non-nuclear medicine techniques. Firstly, some practical solutions can be set up in radiopharmacy departments such as using more than two generators together, realizing fractionated elutions, preparing radiopharmaceuticals with elutions providing from different generators.. Then, it could be interesting to have a reflexion in nuclear medicine departments to convene patients the days when 99m Tc supply is sufficient, to pool some exams or to make substitutions with more available isotopes. (authors)

  6. IL-2 labeled with 99mTechnetium by an indirect method

    International Nuclear Information System (INIS)

    Bocco, R.; Obenaus, Esteban; Rabiller, Graciela; Castiglia, Silvia G. de

    2003-01-01

    IL-2 and the other cytokines labeled with 99m Tc are an interesting option to early diagnosis of autoimmune diseases and monitoring with nuclear medicine images. The aim of this study was to obtain by indirect method IL-2 labeled with 99m Technetium using Benzoyl MAG3 chelating agent, for in vivo diagnosis of lymphocytic infiltration. IL-2 is a small, relatively fragile protein, and it is essential to retain its receptor binding capacity after labeling. Two different methods of labeling have been proven: Pre-conjugation labeling method: we used NHS- Hynic as a chelator agent and labeled this conjugated protein with 99m Tc using tricine as coligand. Albumin was used as a model for the conjugation and labeling steps. The albumin was labeled by this method with a good labeling efficiency but the IL-2 protein could not be labeled with this approach. Post- conjugation labeling method: we used the bifunctional chelating agent, benzoyl MAG3, this ligand is first labeled with 99m Tc and then is conjugated to the protein. The N 3 S Logan complex was incubated for 30 minutes and then measured by RP- HPLC. An active ester of the labeled Logan was formed and was incubated with Il-2 at room temperature and basic pH to promote the conjugation between the active ester and the protein. The labeling efficiency was determined by RP-HPLC using a C 18 column. The albumin protein was also labeled by this method and the radiochemical purity was measured by RP- HPLC using a GPC column and the labeling efficiency was 80%. The next objectives are to explore different strategies for purifying the 99m Tc-IL-2 and to evaluate the capacity of IL-2 to bind to its receptor after labeling. (author)

  7. Evaluation of technetium-99m/rhenium labelled nucleoside analogues as potential radiotracers in oncology

    International Nuclear Information System (INIS)

    Desbouis, D.

    2007-01-01

    Over the last decade, suicide gene therapy has emerged as a very promising method to treat cancer. This therapy consists of introducing new genetic material into the nucleus of cancer cells so that they express a therapeutic protein. The protein leads to a therapeutic effect upon interaction with a prodrug. The most widely used system is the combination of the enzyme Herpes Simplex Virus Thymidine Kinase of type 1 (HSV1-TK) with the nontoxic antiviral prodrug gancyclovir. The efficiency of protein expression is crucial for a successful therapy. Several Positron Emission Tomography (PET) tracers such as 9-[4-[ 18 F]fluoro-3-(hydroxymethyl)butyl]guanine [ 18 F]FHBG) or [ 124 I]iodo-2'-fluoro-2'-deoxy-l-β-D-arabino-furanosyluracil ( 124 I]FIAU) have been shown to be suitable probes for reporting HSV1-TK expression. One aspect of this work was to develop Single Photon Emission Tomography (SPET) reporter probes based on the inexpensive technetium-99m whose physical properties are well-suited for diagnosis (t 1/2 = 6.02 h; E γ = 140 keV). A series of complexes was prepared by derivatizing the precursor 5'-amino-5'-deoxythymidine at position N5' in order to introduce spacers of various lengths (∼ 0-30 aangstroem) carrying tridentate metal chelating entities such as iminodiacetic acid and picolylamine-N-monoacetic acid. The nucleoside derivatives were reacted with the precursors [ReBr 3 (CO) 3 ] 2- and [ 99m Tc(OH 2 ) 3 (CO) 3 ] + to form water-stable organometallic thymidine complexes. Unexpectedly, most of the compounds showed no inhibition of HSV1-TK but a mixed inhibition of the human cytosolic thymidine kinase with K iu values ranging from 4.4-334 μM. Competitive inhibition of HSV1-TK was only observed for the thymidine analogue in which the base and the metal core were separated by a spacer of approximately 30 aangstroem length (K i = 16.3 ± 4.6 μM). This compound also exhibited a mixed inhibition of the hTK1 with K ic = 73 ± 20 μM. When tested in vitro for

  8. Measurement of lymphatic function with technetium-99m-labelled polyclonal immunoglobulin

    International Nuclear Information System (INIS)

    Svensson, W.; Glass, D.M.; Bradley, D.; Peters, A.M.

    1999-01-01

    A reliable method for measuring lymph flow in physiological units would be valuable, especially in conditions in which it is uncertain whether lymph flow is increased or decreased. The requirements of a radiopharmaceutical for such measurement include stable radionuclide labelling and rapid access to lymphatic vessels following tissue injection but no access to blood vessels. A soluble macromolecule is likely to come closest to meeting these requirements. Technetium-99m- labelled human polyclonal immunoglobulin (HIG) was therefore investigated firstly in comparison with 99m Tc-labelled human serum albumin (HSA) in patients undergoing routine lymphoscintigraphy and secondly with respect to injection site in a group of volunteers with post-mastectomy oedema (PMO). Subcutaneous injection of 99m Tc-HIG into the web space of a distal extremity gave images in which lymphatic vessels were more clearly defined compared with images obtained after injection of 99m Tc-HSA. Lymph nodes were also more clearly defined, suggesting specific retention of HIG, possibly through Fc-mediated binding. Peripheral blood sampling showed a delayed arrival in blood of radioactivity after 99m Tc-HIG compared with 99m Tc-HSA, although ultimately, the blood recovery of 99m Tc-HIG was significantly higher (P 99m Tc-HSA. Clearance rates of radioactivity from the injection site were not sinificantly different, however, between the two agents. In patients with PMO, web space injection of 99m Tc-HIG gave excellent images of normal lymphatic vessels, of lymph nodes and of abnormal lymph drainage such as dermal backflow in swollen arms. In contrast, neither lymphatic vessels nor lymph nodes were visualised after injection into the skin of the dorsum of the distal forearm. Although there was no difference in clearance rates from the injection sites between normal and swollen arms with either agent in PMO, clearance was significantly faster following injection into the web space (0.11% per minute for

  9. Technetium{sup 99m} shortage: Practical solutions to manage lack of the radio-isotope in nuclear medicine departments; Penurie de technetium{sup 99m}: des pistes pratiques pour gerer les periodes de crise dans les services de medecine nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Biechlin-Chassel, M.L. [Radiopharmacie, service de pharmacie, centre hospitalier de Chambery, 73 - Chambery (France); Francois-Joubert, A. [Service de medecine nucleaire, centre hospitalier de Chambery, 73 - Chambery (France); Bolot, C. [Service de radiopharmacie, service pharmaceutique, centre de medecine nucleaire, groupement hospitalier Est, 69 - Bron (France); Desruet, M.D. [Radiopharmacie, service de medecine nucleaire, CHU de Grenoble, 38 - Grenoble (France); Bourrel, F. [Services de pharmacie et medecine nucleaire, centre hospitalier d' Avignon, 84 - Avignon (France); Pelegrin, M. [Institut de recherche en cancerologie (IRCM), 34 - Montpellier (France); Inserm U896, universite Montpellier 1, 34 - Montpellier (France); CRLC Val d' Aurelle Paul-Lamarque, 34 - Montpellier (France); Couret, I. [Service de medecine nucleaire, hopital Lapeyronie, 34 - Montpellier (France); Lao, S. [Service de medecine nucleaire, CHU Hopital de l' Archet, 06 - Nice (France); Quelven, I. [Faculte de medecine, 87 - Limoges (France)

    2010-11-15

    Technetium{sup 99m} ({sup 99m}Tc) shortage crisis regularly affect nuclear medicine activity and oblige the community to find solutions in order to perform most of the prescribed exams and avoid systematic substitutions by other non-nuclear medicine techniques. Firstly, some practical solutions can be set up in radiopharmacy departments such as using more than two generators together, realizing fractionated elutions, preparing radiopharmaceuticals with elutions providing from different generators.. Then, it could be interesting to have a reflexion in nuclear medicine departments to convene patients the days when {sup 99m}Tc supply is sufficient, to pool some exams or to make substitutions with more available isotopes. (authors)

  10. Dynamic SPECT of the brain using a lipophilic technetium-99m complex, PnAO

    DEFF Research Database (Denmark)

    Holm, S; Andersen, A R; Vorstrup, S

    1985-01-01

    m PnAO was injected i.v. as a bolus of 15 to 25 mCi. The distribution was followed over 10-sec intervals using a highly sensitive, rapidly rotating SPECT (Tomomatic 64) and compared to 133Xe flow maps. Upon arrival of the PnAO bolus to the brain, a high uptake was found in brain tissue with high......The lipophilic 99mTc-labeled oxime propylene amine oxime (PnAO) should, according to recent reports behave like 133Xe in the human brain. This study compares SPECT images of the two tracers in six subjects: four stroke cases, one transitory ischemic attack case and one normal subject. Technetium-99......AO has a high yet incomplete brain extraction yielding a flow dominated initial distribution with limitations mentioned....

  11. Comparison of liver scintigraphy with /sup 99m/Tc-phytate and /sup 198/Au-colloid in diffuse hepatic disorders

    Energy Technology Data Exchange (ETDEWEB)

    Kamoi, I; Watanabe, K; Kawahira, K; Nakayama, C; Higashi, Y [Kyushu Univ., Fukuoka (Japan). Faculty of Medicine

    1975-07-01

    sup(99m)Tc-phytate was evaluated as a liver scintigraphic radiopharmaceutical, and the results were compared with those of /sup 198/Au-colloid. Both radionuclides were used on the same day in 55 cases of diffuse hepatic disorders. In 52 of the 55 cases, excellent liver images were obtained with sup(99m)Tc-phytate. Compared with /sup 198/Au-colloid, sup(99m)Tc-phytate was more highly concentrated in the spleen and bone marrow and with higher background radioactivity, although their distributions generally coincided. The known diagnostic criteria for liver scintigraphy with /sup 198/Au-colloid in diffuse hepatic disorders were proven applicable to sup(99m)Tc-phytate.

  12. Inflammation Scan Using {sup 99m}Tc-HMPAO Labelled Leukocytes

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Woo Jin; Chung, Soo Kyo; Shinn, Kyung Sub; Bahk, Yong Whee; Kim, Hoon Kyo [Catholic University College of Medicine, Seoul (Korea, Republic of)

    1989-07-15

    Inflammation scan using radiolabelled leukocytes has high sensitivity and specificity. Several methods for labelling leukocytes have been evaluated using P-32 diisopropyl fluorophosphate (DFP -32), H-3 thymidine, Cr-51 chromate, Ga-67 citrate and {sup 99m}Tc-sulfur colloid. In-111-oxine has proved so far to be the most reliable agent for labelling leukocytes. In-111-oxine is, however, expensive, not easily available when needed, and its radiation dose to leukocytes is relatively high. Moreover, resolution of the resultant image is relatively poor. {sup 99m}Tc is still the agent of choice because of, as compared with the indium, its favorable physical characteristics, lower cost and availability. Now the technique for labelling the leukocytes with technetium is successfully obtained using the lipophilic HMPAO with higher efficiency for granulocytes than for other cells. With this technique it is possible to label leukocytes in plans to improve the viability of the leukocytes. Inflammation scan using {sup 99m}Tc-HMPAO has been evaluated in several laboratories, and difference in methods for separation and labelling accounts for difference in efficiency, viability and biodistribution of the labelled leukocytes. We performed inflammation scan using leukocytes labelled with {sup 99m}Tc-HMPAO in three dogs 24 hours after inoculation of live E. Coli and S. Aureus in their right abdominal wall. We separated mixed leukocytes by simple sedimentation using 6% hetastarch (HES) and labelled the leukocytes with {sup 99m}Tc-HMPAO in 20% cell free plasma diluted with phosphate buffer solution. Uptake was high in the liver and spleen but is was minimal in the lungs on whole body scan. Kidneys and intestine showed minimal activity although it was high in the urinary bladder. Uptake of labelled leukocytes in the inflammation site was definite on 2 hour-postinjection scan and abscess was clearly delineated on 24 hour-delayed scan with high target-to-nontarget ratio. 4). Inflammation

  13. Synthesis and biodistribution of nitrido technetium-99m radiopharmaceuticals with dithiophosphinate ligands: a class of brain imaging agents

    Energy Technology Data Exchange (ETDEWEB)

    Bellande, Emmanuel; Comazzi, Veronique; Laine, Jacques; Lecayon, Michele; Pasqualini, Roberto; Duatti, Adriano; Hoffschir, Didier

    1995-04-01

    The symmetrical complexes [{sup 99m}Tc][TcN(R{sub 2}PS{sub 2}){sub 2}] [R = CH{sub 3}, CH{sub 2}CH{sub 3}, CH{sub 2}CH{sub 2}CH{sub 3}, CH{sub 2}(CH{sub 3}){sub 2}], and the unsymmetrical complex [{sup 99m}Tc][TcN(Me{sub 2}PS{sub 2})(Et{sub 2}PS{sub 2})] have been prepared, at tracer level, through a two-step procedure involving the preliminary formation of a prereduced technetium nitrido intermediate followed by substitution reaction onto this species by the appropriate dithiophosphinate ligand [R{sub 2}PS{sub 2}]Na. The chemical identity of the resulting complexes have been established by comparison with the corresponding {sup 99}Tc-analogs prepared, at macroscopic level, by reacting the complex [{sup 99}TcNCl{sub 4}] [n-Bu{sub 4}N] (n-Bu = n-butyl) with an excess of ligand in methanol, and characterized by elemental analyses and spectroscopic techniques. The complexes are neutral and lipophilic, and possess a square pyramidal geometry, with an apical Tc N group and two dithiophosphinate ligands spanning the four positions on the basal plane through the four sulfur atoms of the >PS{sub 2} group. In vitro studies showed that these radiopharmaceuticals are stable in solution and that their chemical identity was not altered after incubation with rat blood. Biodistribution studies have been carried out in rats and primates. The results demonstrate that these compounds are significantly retained into the brain of these animals for a prolonged time. Planar gamma camera images have been obtained in monkeys showing a good visualization of the cerebral region. However, the existence of persistent blood activity yields a brain/blood ratio lower than that observed with other {sup 99m}Tc-based brain perfusion imaging agents.

  14. A new method for the preparation of 99mTc-stannous colloid instant kit

    International Nuclear Information System (INIS)

    Chen Shaoliang; Zhao Huiyang

    1988-01-01

    A new way for the preparation of 99m Tc-stannous cooloid instant kit, its animal experimental results and its application to clinical practice were described. 500 mg sodium fluoride and 25 mg stannous chloride were dissolved in 50 ml sterile water, and the pH was adjusted to 6.4 with 0.05 mol/LHCl 0.5 millilitre of this solution was filtered into a vial and dryed under sterile condition. The kit can be used immediately after adding 2 ∼ 4 ml of 99m TcO 4 . It is suitable for intravenous administration as a imaging agent for liver or other organs of the reticuloerdothelial (RE) system. Distribution stadies of the 99m Tc-stannous colloid in rats showed a rapid clearance of radioactivity from the blood stream and a subsequent rapid increase of radioactivity in the liver, up to approximately 90% of the injected dose. No toxic reactions were observed in rabbits at a dose of 1 ml of 99m Tc-stannous colloid/kg

  15. Improved modification for in vitro labeling of red blood cells with Technetium-99m

    International Nuclear Information System (INIS)

    Gerson, B.; Ballinger, J.R.; Gulenchyn, K.Y.

    1988-01-01

    The authors have tested a modification of Brookhaven method for in vitro labeling of red blood cells (RBCs) with technetium-99m by adding an initial centrifugation step and performing the labeling on packed RBCs. This results in reproducible, high labeling efficiencies (99.3% +/- 0.4%, n = 50) after 15 min of incubation. The use of packed RBCs also results in a higher concentration of labeled RBCs (smaller bolus for injection) and less radiation exposure to the technologist. This technique has proved useful for radionuclide angiography, venography, gastrointestinal bleeding studies, and red cell mass determinations. It is particularly advantageous for RBC labeling in patients receiving chemotherapy

  16. Technetium-99m labeled somatostatin and analogs: synthesis, characterization and in vivo evaluation

    International Nuclear Information System (INIS)

    Amartey, J.K.

    1993-01-01

    Technetium-99m complexes of somatostatin and analogs were synthesized following the introduction of sulfhydryl groups with 2-iminothiolane (Traut's Reagent). In rats the complex was taken up by the liver, kidneys, adrenals, lungs and the pancreas. Analysis of urine samples of treated rats showed that the radiochemicals have reasonably good in vivo stability. This implies that the complexes may be potentially useful for biochemical characterization of somatostatin receptors and also in scintigraphic detection of somatostatin receptor positive tumors, especially for metastatic deposits in patients on somatostatin therapy. (Author)

  17. Technetium-99m scintigraphy associated with spondylolysis of the lumbar spine in children

    International Nuclear Information System (INIS)

    Kubota, Wataru; Sudo, Nariomi; Nakazima, Kiyonori; Nakamura, Mitsutaka

    1987-01-01

    Eight children with spondylolysis, aged from 10 to 18 years of age, underwent bone scanning with technetium-99m methylene diphosphonic acid. Radioisotope (RI) uptake was significantly observed in the site marked by the separation of the pars interarticularis, compared with the other sites between the articular processes. This showed the increase in metabolic activity of bones, providing supplementary information in the initial diagnosis. At the completion of conservative treatment, RI uptake decreased, being seemingly attributable to the improvement of subjective symptoms. Bone scanning may, however, be unhelpful in detecting synostosis. (Namekawa, K.)

  18. Technetium-99m scintigraphy associated with spondylolysis of the lumbar spine in children

    Energy Technology Data Exchange (ETDEWEB)

    Kubota, W.; Sudo, N.; Nakazima, K.; Nakamura, M.

    1987-02-01

    Eight children with spondylolysis, aged from 10 to 18 years of age, underwent bone scanning with technetium-99m methylene diphosphonic acid. Radioisotope (RI) uptake was significantly observed in the site marked by the separation of the pars interarticularis, compared with the other sites between the articular processes. This showed the increase in metabolic activity of bones, providing supplementary information in the initial diagnosis. At the completion of conservative treatment, RI uptake decreased, being seemingly attributable to the improvement of subjective symptoms. Bone scanning may, however, be unhelpful in detecting synostosis.

  19. Enterogastroesophageal reflux detected on 99m-technetium sestamibi cardiac imaging as a cause of chest pain

    International Nuclear Information System (INIS)

    Erdogan, Zeynep; Silov, Güler; Özdal, Aysegül; Turhal, Özgül

    2013-01-01

    Myocardial perfusion imaging (MPI) with technetium-99m sestamibi ( 99m Tc MIBI) is considered a diagnostic technique that is widely used for the investigation of suspected coronary artery disease. Incidental inspection of an extracardiac activity is indirect, but important marker, which can identify a potentially treatable non-coronary cause for chest pain that may mimic cardiac symptoms. Here, we present an illustrative case in which significant enterogastroesophageal reflux of 99m Tc MIBI occurred during the cardiac imaging following prompt hepatobiliary clearance. Because, there was normal myocardial perfusion on MPI, presence of gastroesophageal reflux (GER) on GER scintigraphy and detection of mild inflammation with pathologically confirmed hyperplastic polyp by endoscopy, in view of the above findings we concluded that the probable cause of chest pain was reflux. (author)

  20. Determination of technetium-99 from complex matrix

    International Nuclear Information System (INIS)

    Lixiong Wang; Lei Tang; Tongzai Yang; Yanqiu Yang; Liang Yang

    2013-01-01

    This paper reports an approach that can be used for efficient separation and determination of 99 Tc (as pertechnetate) after contamination of the environment by nuclear materials. The samples were decomposed by fusion in a mixture of potassium hydroxide and potassium nitrate. After fusion, technetium remains as the pertechnetate anion (TcO 4 - ). The technetium was isolated from the sample by technique combining solvent extraction, anion exchange, then, again, solvent extraction. After separation, 99 Tc was measured by isotope-dilution mass spectrometry with 97 Tc as spike. This method yielded nanogram detection limits for 99 Tc. (author)

  1. Detection of Metastases of Primary Hepatocellular Carcinoma with {sup 99m}Tc-HIDA Scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Huh, Dae Suk [Seoul National University College of Medicine, Seoul (Korea, Republic of); Hong, Kee Suk; Hong, Seong Woon; Lee, Jhin Oh; Kang, Tae Woong [Cancer Reseach Hospital, Korea Advanced Energy Institute, Seoul (Korea, Republic of)

    1983-03-15

    {sup 99m}Tc-Sulfur Colloid is concentrated in Kupffer cells of the liver, whereas the new biliary agents such as {sup 99m}Tc-HIDA are processed by hepatic parenchymal cells. The distant metastatic lesions in skull and lung of the primary hepatocellular carcinoma in 38-year old Korean male were detected with {sup 99m}Tc-HIDA scintigraphy. The chest PA, skull bone X-ray and radionuclide scintigraphic studies are illustrated. This observation suggests that {sup 99m}Tc-HIDA scintigraphy is useful for detection of distant metastases of primary hepatocellular carcinoma.

  2. Scintigraphic scoring system for grading severity of gastro-esophageal reflux on 99mTc sulfur colloid gastro-esophageal reflux scintigraphy: A prospective study of 39 cases with pre and post treatment assessment.

    Science.gov (United States)

    Puranik, Ameya D; Nair, Gopinathan; Aggarwal, Rajiv; Bandyopadhyay, Abhijit; Shinto, Ajit; Zade, Anand

    2013-04-01

    The study aimed at developing a scoring system for scintigraphic grading of gastro-esophageal reflux (GER), on gastro-esophageal reflux scintigraphy (GERS) and comparison of clinical and scintigraphic scores, pre- and post-treatment. A total of 39 cases with clinically symptomatic GER underwent 99mTc sulfur colloid GERS; scores were assigned based on the clinical and scintigraphic parameters. Post domperidone GERS was performed after completion of treatment. Follow up GERS was performed and clinical and scintigraphic parameters were compared with baseline parameters. Paired t-test on pre and post domperidone treatment clinical scores showed that the decline in post-treatment scores was highly significant, with P value reflux and also for following children post-treatment.

  3. The technetium-99m DTPA partition test in the diagnosis of tuberculous meningitis

    International Nuclear Information System (INIS)

    Von Wenzel, K.S.; Klopper, J.F.; Wasserman, H.J.

    1989-01-01

    Although the blood/cerebrospinal fluid (CSF) bromide concentration ratio is sensitive and specific in the diagnosis of tuberculous meningitis (TBM), bromide-82 is not always available since it is not generally used in nuclear medicine. The use of technetium-99m diethylenetriamine penta-acetic acid (DTPA) for a partition test was compared with that of 82 Br in 22 cases. Seven patients were diagnosed as having TBM, 9 patients had viral meningitis and 5 patients had septic meningitis. One normal control subject was also studied. Although the mechanism of transfer of substances across the blood-brain barrier as well as the factors affecting it are still unclear, both 82 Br and 99m Tc-DTPA cross the blood-brain barrier to a greater extent in TBM than in viral meningitis. Both tracers thus yield decreased serum/CSF concentration ratios in TBM. The accuracy of the 82 Br partition test was found to be 90,9% if a critical serum/CSF ratio of 1,3 was chosen, compared with 86,9% for the 99m Tc-DTPA partition test if a critical value of 3 was chosen. The use of 99m Tc D TPA offers various advantages, including general availability, lower cost and radiation dose per MBq, as well as the possibility of concomitant brain scintigraphy. 1 tab., 9 refs

  4. Studies on the production of technetium-99m generators based on gel elution

    International Nuclear Information System (INIS)

    Castro, M.

    1993-12-01

    Technetium-99m generator based on Ti Mo elution has been carried out. The gel matrix was prepared by mixing non-irradiated molybdate with Titanium Chloride solution. Conditions of preparing and drying Ti Mo were evaluated as a function of elution yield. Thus, pH and water content were found highly critical for reproductiveness of the results. Non-elutable form of Tc-99m can be oxidized treating the target after irradiation with K 2 Cr 2 O 7 0.001M solution. During several experiments the columns were soaked with this oxidizing solution for one hour and afterwards the Ti Mo was washed with 150 ml physiological saline. Daily elutions were done with 10 ml of NaCl 0.9%. Cooling water reactor during irradiation quartz ampoules has been studied. To study this effect, one group of samples were irradiated in aluminium caps air-tight screw and another one was irradiated in drilled caps with six holes to permit water reactor recirculation around quartz ampoules. By combination K 2 Cr 2 O 7 target treatment and cooling Ti Mo during irradiation is possible to get yields of Tc-99m near to 76%. The radiochemical purity was > 99% and Al content < 10ppm , Cr < 0.05ppm , Mo <20ppm, Ti was no detected. Biological scans practiced in animals have been considered satisfactory. (author). 8 refs., 7 tabs., 3 figs

  5. Detection of homing-in of stem cells labeled with technetium-99m hexamethylpropyleneamine oxime in infarcted myocardium after intracoronary injection

    International Nuclear Information System (INIS)

    Patel, Chetan D; Agarwal, Snehlata; Seth, Sandeep; Mohanty, Sujata; Aggarwal, Himesh; Gupta, Namit

    2014-01-01

    Bone marrow stem cells having myogenic potential are promising candidates for various cell-based therapies for myocardial disease. We present here images showing homing of technetium-99m (Tc-99m) hexamethylpropyleneamine oxime (HMPAO) labeled stem cells in the infarcted myocardium from a pilot study conducted to radio-label part of the stem cells in patients enrolled in a stem cell clinical trial for recent myocardial infarction

  6. A comparison of dose savings of lead and lightweight aprons for shielding of 99m-Technetium radiation

    International Nuclear Information System (INIS)

    Warren-Forward, H.; Cardew, P.; Smith, B.; Clack, L.; McWhirter, K.; Johnson, S.; Wessel, K.

    2007-01-01

    Nuclear medicine technologists (NMTs) have the highest effective doses of radiation among medical workers. With increase in the use of lightweight materials in diagnostic radiography, the aim was to compare the effectiveness of lead and lightweight aprons in shielding from 99m-Technetium ( 99m Tc) gamma rays. The doses received from a scattering phantom to the entrance, 9 cm depth and exit of a phantom were measured with LiF:Mg, Cu, P thermoluminescent dosemeters (TLDs). Doses and spectra were assessed without no shielding, with 0.5-mm lead and lightweight aprons. The lead and lightweight aprons decreased entrance surface doses by 76 and 59%, respectively. The spectral analysis showed that the lightweight apron provided better dose reduction at energies 99m Tc labelled radiopharmaceutical. (authors)

  7. Tc-99m colloid lung uptake in a rare case of toxoplasmosis with liver involvement

    International Nuclear Information System (INIS)

    Garty, I.; Tal, I.; Kaynan, A.

    1984-01-01

    Intensive lung accumulation of colloid (Tc-99m phytate) was demonstrated in a child suffering from acquired toxoplasmosis with a rare manifestation of severe liver damage. The possible mechanism and clinical importance of colloid lung concentration in this case is briefly discussed, including a review of the literature on this subject

  8. Technetium-99m HM-PAO-SPECT study of regional cerebral perfusion in early Alzheimer's disease

    International Nuclear Information System (INIS)

    Perani, D.; Di Piero, V.; Vallar, G.

    1988-01-01

    Regional cerebral perfusion was evaluated by single photon emission computed tomography (SPECT) using technetium-99m hexamethylpropyleneamine oxime ([/sup 99m/Tc]HM-PAO) in sixteen patients with Alzheimer's disease (AD) in early clinical phase and in 16 healthy elderly controls. In all patients transmission computed tomography (TCT) and/or magnetic resonance imaging (MRI) did not show focal brain abnormalities. Relative to normal subjects, AD patients showed significant reductions in cortical/cerebellar activity ratio: cortical perfusion was globally depressed with the largest reductions in frontal and posterior temporo-parietal cortices. Asymmetries of relative perfusion between cerebral hemispheres were also demonstrated when language was affected or visuospatial functions were unevenly impaired. In patients with early AD, SPECT provides functional information to be compared with clinical and psychometric data

  9. Studies on the Effect of 99Tc in colloid on enzyme activity(G.p.x ,G.S.T,SOD) before and after used diadzain

    International Nuclear Information System (INIS)

    Ahmood, A. M.; Alwan, I. F.; Abd Al-Kream, H. M.

    2012-12-01

    This study was conducted to determine the effect of Tin -colloid labeled with Technetium -99m on some enzyme activities of treated mice. it was noticed that an increase in the level of Glutathione-S- transferase (GST) glutathione peroxidase (Gpx), super oxide dismutase (SOD) and malonaldehyde (MDA) levels for treated (20) mice compared to the level of control mice Group (20). After That, the use diadzein extracted from soy been and linseed with concentrate of (0.250 mg/Kg), (0.500/Kg) on mice Group (20). It was found decreased activities GST, Gpx , SOD and MDA compared with 9 9mT c Tin-colloid Group without diadzein. (Author)

  10. Technetium-99m sestamibi limb scintigraphy in post-traumatic reflex sympathetic dystrophy: preliminary results

    International Nuclear Information System (INIS)

    Sarikaya, A.; Firat, M.F.; Sarikaya, I.; Pekindil, G.; Pekindil, Y.

    2001-01-01

    Reflex sympathetic dystrophy (RSD) has widely variable clinical manifestations. Its pathogenesis remains partially unexplained. RSD is commonly divided into three stages; these stages are not always clearly separable, but staging remains important for correct treatment. Since the disease involves soft tissue alterations as well as bone changes, we decided to investigate whether technetium-99m sestamibi limb imaging can be used to evaluate the soft tissue appearance. Fifteen patients (seven females and eight males; age range 12-68 years) with clinically significant post-fracture RSD were evaluated with both three-phase bone scan (TPBS) and 99m Tc-sestamibi limb scintigraphy. Although, in general, patients with similar duration of disease, clinical stage and TPBS activity tended to have similar patterns of sestamibi uptake, discordant uptake patterns were observed in some patients with clinical stage 1. Thus, of 12 patients with stage I disease, eight had increased 99m Tc-sestamibi activity in the distal part of the affected limb, while three had normal activity and one had decreased activity. All three patients with stage II disease showed normal 99m Tc-sestamibi uptake. Although most of the patients with increased 99m Tc-sestamibi uptake had increased activity on all three phases of the bone scan, there were discordant results between the scan patterns in other patients. On the basis of these findings, we suggest that 99m Tc-sestamibi imaging may contribute to the differentiation between clinical stages and may permit evaluation of the disease course and selection of appropriate therapy. 99m Tc-sestamibi imaging is not, however, a primary diagnostic procedure for RSD. (orig.)

  11. Technetium-99m-ECD SPECT in antiphospholipid antibody syndrome: a drastic improvement in brain perfusion by antiplatelet therapy

    Energy Technology Data Exchange (ETDEWEB)

    Tokumaru, Sunao; Yoshikai, Tomonori; Uchino, Akira; Kudo, Sho [Dept. of Radiology, Saga Medical School (Japan); Matsui, Makoto; Kuroda, Yasuo [Dept. of Neurology, Saga Medical School (Japan)

    2001-12-01

    We present a case of antiphospholipid antibody syndrome (APS) with repeated transient ischemic attacks (TIAs). Magnetic resonance imaging showed multiple cerebral infarcts and ischemic changes in the cerebral white matter. Cerebral angiographies showed no abnormalities. Technetium-99m-ethyl cysteinate dimer (Tc-99m-ECD) brain SPECT showed multiple decreased perfusion areas, which were more extensive than the lesions demonstrated on MRI. After treatment with an antiplatelet agent, the patient subsequently recovered from the TIAs. Although no interval changes were observed by MRI after therapy, follow-up Tc-99m-ECD SPECT revealed a marked improvement in brain perfusion. This is the first imaging report of remarkable post-therapy improvement in brain perfusion in APS cases. (orig.)

  12. Technetium-99m-ECD SPECT in antiphospholipid antibody syndrome: a drastic improvement in brain perfusion by antiplatelet therapy

    International Nuclear Information System (INIS)

    Tokumaru, Sunao; Yoshikai, Tomonori; Uchino, Akira; Kudo, Sho; Matsui, Makoto; Kuroda, Yasuo

    2001-01-01

    We present a case of antiphospholipid antibody syndrome (APS) with repeated transient ischemic attacks (TIAs). Magnetic resonance imaging showed multiple cerebral infarcts and ischemic changes in the cerebral white matter. Cerebral angiographies showed no abnormalities. Technetium-99m-ethyl cysteinate dimer (Tc-99m-ECD) brain SPECT showed multiple decreased perfusion areas, which were more extensive than the lesions demonstrated on MRI. After treatment with an antiplatelet agent, the patient subsequently recovered from the TIAs. Although no interval changes were observed by MRI after therapy, follow-up Tc-99m-ECD SPECT revealed a marked improvement in brain perfusion. This is the first imaging report of remarkable post-therapy improvement in brain perfusion in APS cases. (orig.)

  13. Technetium-99m pyrophosphate imaging in acute renal failure associated with nontraumatic rhabdomyolysis

    Energy Technology Data Exchange (ETDEWEB)

    Patel, R.; Mishkin, F.S.

    1986-10-01

    Technetium-99m pyrophosphate (Tc-PYP) imaging was performed in five patients with acute renal failure associated with nontraumatic rhabdomyolysis. Four patients had phencyclidine intoxication and one had viral pneumonia. During the acute phase, marked uptake of pyrophosphate was seen in all patients in several muscle groups, but always in the thigh adductors. The results show that phencyclidine intoxication can result in diffuse muscle uptake of Tc-PYP without overt evidence of muscle injury. Tc-PYP imaging may provide a clue to the cause of acute renal failure in patients with suspected rhabdomyolysis in whom elevations of serum creatine phosphokinase concentrations are equivocal.

  14. Technetium-99m pyrophosphate imaging in acute renal failure associated with nontraumatic rhabdomyolysis

    International Nuclear Information System (INIS)

    Patel, R.; Mishkin, F.S.

    1986-01-01

    Technetium-99m pyrophosphate (Tc-PYP) imaging was performed in five patients with acute renal failure associated with nontraumatic rhabdomyolysis. Four patients had phencyclidine intoxication and one had viral pneumonia. During the acute phase, marked uptake of pyrophosphate was seen in all patients in several muscle groups, but always in the thigh adductors. The results show that phencyclidine intoxication can result in diffuse muscle uptake of Tc-PYP without overt evidence of muscle injury. Tc-PYP imaging may provide a clue to the cause of acute renal failure in patients with suspected rhabdomyolysis in whom elevations of serum creatine phosphokinase concentrations are equivocal

  15. A simple method to determine the blood volume of newborns with serum-albumin labeled with technetium-99m (HSA-sup(99m)Tc)

    International Nuclear Information System (INIS)

    Camargo, E.E.; Vaz, F.A.C.; Rockmann, R.L.; Barreto, T.M.; Eston, T.E. de; Carvalho, N.

    1973-01-01

    A method for determination of small volumes, with which it is determined blood volume of 11 newborns, is described. By injecting through the anterior fontannelle 1 ml a human serum albumin solution labelled with technetium-99m and withdrawing from the posterior fontanelle blood samples of 1.2 to 1.5 ml at 10, 20 and 30 minutes after the injection, the possibility of determining blood volume with only two of these samples without using a standard is shown. Non-significant whole body radiation (3.2 mrad/6h) is shown as well [pt

  16. Status of Tc-99m and 99Mo/99mTc generator production in Bangladesh

    International Nuclear Information System (INIS)

    Abedin, Md. Zainul; Haque, Md. Azizul; Ali, Md. Ramjan; Hossain, Md. Anwar; Razzaque, Md. Abdur; Yasmin, Lyzu; Waheed, M. Fatima; Akhter, Rabeya; Mondal, Rafiuddin

    2007-01-01

    Radioisotope Production Division (RIPD) produced instant technetium-99m by solvent extraction method for several years. On R and D basis, the division produced portable sterile Tc-99m sublimation generator by irradiating titanium molybdate in the reactor. The division produced (4/batch) from imported fission Mo-99 till June 2005. Since August 2005, as per demand of the government hospitals, the division have been producing 12-14 pieces of 15 GBq chromatographic 99m Tc-generators weekly by using the new generator production plant installed last year having online Mo-99 loading system with the of producing 50 generator per batch. Development of PZC and (n,γ) 99 Mo based generator holds potential in Bangladesh. (author)

  17. The role of Technetium99m-MIBI in the follow-up of differentiated thyroid carcinoma

    International Nuclear Information System (INIS)

    Machado, L.S.; Corbo, R.; Pedras, D.S.V.; Anttonuccia, J.B.

    2004-01-01

    Full text: Technetium-99m-methoxyisobutylisonitrile (99mTc-MIBI) is being used as a tumor-seeking agent over the last few years. We evaluated the role of 99mTc-MIBI whole body scan (WBS) in localizing metastatic lesions in patients with thyroid cancer and compared the results with 131I scan and serum thyroglobulin (Tg) levels. Eighty nine patients of differentiated thyroid cancer subjected to thyroidectomy were enrolled for the study. Early (20 minutes) and delayed (6 and 24 hours) whole body images were obtained after injecting 99mTc-MIBI. Tg measurements were obtained during thyroid hormone replacement and 4 weeks after hormone discontinuation. 131I scans were performed after low diagnostic or high ablative/therapeutic dose. These methods were used as standard to evaluate the presence of residual or metastatic thyroid cancer. The patients with positive 99mTc-MIBI scan but negative 131I scan underwent chest x-ray, computed tomography (CT) or magnetic resonance imaging (MRI). 34 of the total 89 patients were found to be negative on 131I scan. 23 of these 34 patients had negative 99mTc-MIBI WBS and 11 patients were positive for abnormal MIBI uptake (specificity: 67.6%). Twenty-two patients had both 99mTc-MIBI WBS and 131I scan positive. Eleven patients had 131I scan negative and 99mTc-MIBI WBS positive; seven of those proved to be true positive. From the findings of our study, it may be concluded that although 99mTc-MIBI has low sensitivity for detection of tumor recurrence, it definitely has a role as a supplementary tool to thyroglobulin measurements and 131I scans. (author)

  18. Effects of fenoprofen on the labeling of blood constituents with technetium-99m, the morphology of red blood cells and the plasmid

    International Nuclear Information System (INIS)

    Pereira, Marcia de Oliveira; Rocha, Gabrielle de Souza; Lombardi, Simone dos Santos; Santos-Filho, Sebastiao David; Fonseca, Adenilson de Souza da; Bernardo-Filho, Mario; Pereira, Mario Jose; Geller, Mauro

    2008-01-01

    The aim of this work was to evaluate the effect of fenoprofen on the labeling of blood constituents with technetium- 99m, on the morphology of red blood cells and on the plasmid DNA. Blood samples from Wistar rats were incubated with fenoprofen and the assay of labeling of blood constituents with technetium-99m ( 99m Tc) was performed. Blood cells, plasma, soluble and insoluble fractions of blood cells and plasma were separated. The radioactivity in each fraction was counted and percentage of incorporated radioactivity (%ATI) was determined. Blood smears were prepared, fixed, stained and the qualitative and quantitative morphology of the red blood cells (RBC) was evaluated. Plasmid (pBSK) was incubated with fenoprofen with stannous chloride, and agarose gel electrophoresis procedure was carried out to evaluate genotoxic and the protection of this drug against stannous chloride effect on DNA. In conclusion, under the conditions used in this work, our data suggest that fenoprofen would not affect the fixation of the 99m Tc on the blood constituents, alter the RBC membrane and present genotoxic and redox effects. (author)

  19. Proposal on new formulas for renal depth in the technetium-99m-mercaptoacetyltriglycine (MAG3) scintigraphy

    International Nuclear Information System (INIS)

    Uchiyama, Katsuhiro; Kuniyasu, Yoshio; Niio, Yasuo

    1997-01-01

    Recently, camera-based techniques to measure effective renal plasma flow (ERPF) have become more popular than single plasma sample techniques because camera-based measurements avoid the necessity of delayed plasma samples and in vitro techniques. The measurements of ERPF are used to estimate the clearance of technetium-99m-mercaptoacetyltriglycine (MAG3). However, camera-based techniques are dependent on an accurate estimate of renal depth to correct for soft-tissue attenuation. Then, new formulas for renal depth correction of technetium-99m-MAG3 clearance in place of Toennesen's, M. Ito's, K. Itoh's, and Taylor's methods were tried to establish in this paper. Eleven hundred and seventy patients without any renal disease were objected. The data from measurement of renal depth using X-ray CT in supine position were analyzed statistically. The depths of right kidney (Dr) and left kidney (Dl) were 7.33±1.27 and 7.07±1.27 cm. The correlation coefficients between Dr and height (H), body weight (W), body Surface area (BSA: W 0.425 xH 0.725 x0.007184 m 2 ), age, and abdominal thickness (Ta) were 0.275, 0.709, 0.615, 0.087, and 0.743. The correlation coefficients between Dl and H, W, BSA, age, and Ta were 0.269, 0.732, 0.629, 0.029, and 0.812. Ta had best correlation with both Dr and Dl. The calculation formulas for Dr and Dl using Ta were as follows; Dr=0.32xTa+0.87 cm, and Dl=0.36xTa-0.08 cm. On the other hand, the multiplex calculation formulas of Dr or Dl with H, W, and Ta were as follows; Dr=0.18Ta+8.54x(W/H)+0.75 (r=0.768), and Dl=0.26Ta+5.90x(W/H)-0.16 (r=0.823). The new regression equations provide superior estimates of renal depth compared to conventional equations. Application of these new formulas into camera-based protocols to determine renal clearances may lead to more accurate measurements of ERPF using technetium-99m-MAG3 scintigraphy. (author)

  20. Non-invasive investigation of the upper gastrointestinal tract using technetium - 99m

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, T V [Royal Infirmary, Edinburgh (UK)

    1979-01-01

    The use of technetium - 99m in the non-invasive investigation of the upper gastrointestinal tract is discussed with particular reference to the evolution of a method of assessing gastric function or gastric acid secretion non-invasively and to the applications of this method in the investigation of surgical patients with disease of the upper gastrointestinal tract. The assessment of maximal acid output and the insulin response is described and the use of the test in the diagnosis of pernicious anaemia, hypo- and hyperchlorhydric states, gastric cancer, hiatus hernia and Barrett's oesophagus, coeliac disease, Meckel's diverticulum, and abdominal aortic aneurism outlined. The use of chemicals labelled with this tracer in hepatobilary scanning is briefly described.

  1. Tumor scintigraphy by the method for subtracting the initial image with technetium-99m labeled antibody

    International Nuclear Information System (INIS)

    Karube, Yoshiharu; Katsuno, Kentaro; Ito, Sanae; Matsunaga, Kazuhisa; Takata, Jiro; Kuroki, Masahide; Murakami, Masaaki; Matsuoka, Yuji

    1999-01-01

    The method for subtracting the initial image from the localization image was evaluated for radioimmunoscintigraphy of tumors with technetium-99m (Tc-99m) labeled antibodies. Monoclonal antibodies were parental mouse and mouse-human chimeric antibodies to carcinoembryonic antigen (CEA), designated F11-39 and ChF11-39, respectively, both of which have been found to discriminate CEA in tumor tissues from the CEA-related antigens. After reduction of the intrinsic disulfide bonds, these antibodies were labeled with Tc-99m. In vivo studies were performed on athymic nude mice bearing the human CEA-producing gastric carcinoma xenografts. Though biodistribution results showed selective and progressive accumulation of Tc-99m labeled antibodies at the tumor site, high radioactivity in blood was inappropriate for scintigraphic visualization of the tumors within a few hours. We examined the subtraction of the initial Tc-99m image from the Tc-99m localization image after a few hours. Subtracted images of the same count reflected the in vivo behavior of the Tc-99m radioactivity. The subtracted scintigrams revealed excellent tumor images with no significant extrarenal background. Visualization of the tumor site was dependent on antigen-specific binding and nonspecific exudation. These results demonstrate that a method of subtraction of the initial image may serve as a potentially useful diagnostic method for an abnormal site for agents with a low pharmacokinetic value. (author)

  2. Studies on 99Tcm-sulfur colloid bone marrow scintigraphy in myeloproliferative disorders

    International Nuclear Information System (INIS)

    Liu Yong; Zhang Yifan; Jia Fangxian; Kang Fu; Jian Shiquan

    2002-01-01

    Objective: To discuss the imaging features and changing patterns of bone marrow scintigraphy in myeloproliferative disorders (MPD) as well as its clinical significance. Methods: Bone marrow scintigraphy using 99 Tc m -sulfur colloid 370-550 MBq was performed on 85 MPD patients, including 40 cases of idiopathic myelofibrosis (IMF), 15 of polycythemia vera (PV), 5 of essential thrombocythaemia (ET), 30 of chronic granulocytic leukemia. Also, 40 cases of myelodysplastic syndromes (MDS) were observed in this study. Results: Abnormal bone marrow imaging was found in 88.2% of the 85 patients. The suppression rate of central bone marrow (CBM) and expansion rate of peripheral bone marrow (PBM) in these MPD patients were 61.2% and 56.5%, respectively. The imaging patterns was classified into three types according to the distribution and activity of bone marrow. 1) reduced imaging (31.8%); 2) increased and expanded imaging (27.1%); 3) depressed and expanded imaging (29.4%). Splenomegaly with minimal residual marrow activity was typical for late stages of MPD. Expansion of PBM was the further feature, but of no major importance for improving hematopoiesis of MPD, and it tended to retract during clinical recovery in chronic granulocytic leukemia (CGL). With expanding PBM, unmatched peripheral blood decreasing was found in MDS. The expansion pattern of PBM in different MPD was of relatively definite features. Conclusions: The imaging pattern of bone marrow was correlated with blood work-up data and clinical course or stages of MPD. Bone marrow scintigraphy may be proven useful in differential diagnosis and evaluation of clinical staging and prognosis of MPD

  3. 99mTechnetium labelled Escherichia coli

    International Nuclear Information System (INIS)

    Diniz, S.O.F.; Cardoso, V.N.; Resende, B.M.; Nunan, E.A.; Simal, C.J.R.

    1999-01-01

    Samples of a culture of unlabeled Escherichia coli were incubated with different concentrations of stannous chloride for various time periods. 99m Tc (26.0 MBq) was added to each preparation and the results showed a labelling yield of 98% for E. coli. Since the bacterial viability of 99m Tc-E. coli and E. coli did not show any statistical differences, these results demonstrate that labelling of E. coli with 99m Tc does not modify the bacterial viability, and the radiolabelled bacteria may be a good model to study bacterial translocation

  4. Triamide mercaptide (N/sub 3/S) ligands for Tc-99m as potential Tc-99m renal function agents

    International Nuclear Information System (INIS)

    Fritzberg, A.R.; Kasina, S.; Johnson, D.L.; Eshima, D.

    1985-01-01

    A number of diamide dimercaptide (N/sub 2/S/sub 2/) complexes of Tc-99m have shown potential as renal tubular function radiopharmaceuticals that could replace radioiodinated hippurate (OIH). Evaluation of such ligands suggested that maximum efficiency for tubular secretion and specificity resulted from addition of a carboxylate group. However, such derivatives resulted in chelate ring stereoisomers that were differently transported by the renal tubular system. The problem of stereoisomers was obviated by replacing one sulfur with an effectively planar amido nitrogen. Groups on the nitrogen then result in diastereomers only when an additional asymetric center is present. A series of triamide mercaptide compounds have been synthesized to evaluate this class as ligands for Tc-99m. One of the simplest of the series, mercaptoacetylglycylglycylglycine (MAG/sub 3/), formed a single Tc-99m product in high yield as determined by HPLC. Preliminary results with pmr and ms of the Tc-99 complex indicate a structure consistent with a 1:1 metal to ligand ratio and monooxo technetium group. Biological evaluation of Tc-99m MAG/sub 3/ showed high renal specificity and rate of excretion exceeding OIH in several species including humans. Members of the N/sub 3/S series studied include mercaptoacetylglycylglycyl-amino acids. In some cases with second asymmetric centers, two components were seen on HPLC. In mice several dianionic Tc-99m complexes were excreted faster than OIH, Tc-99m MAG/sub 2/-ala, -asn, and -gln. Trianionic Tc-99m MAG/sub 2/-asp and -glu were excreted more slowly, and Tc-99m MAG/sub 2/-phe showed hepatobiliary excretion. Triamide mercaptides represent a new ligand class for Tc-99m

  5. On-site preparation of technetium-99m labeled human serum albumin for clinical application

    International Nuclear Information System (INIS)

    Wang Yuhfeng; Chuang Meihua; Cham Thauming; Chung Meiing; Chiu Jainnshiun

    2007-01-01

    Technetium-99m labeled human serum albumin (Tc-99m HSA) is an important radiopharmaceutical for clinical applications, such as cardiac function tests or protein-losing gastroenteropathy assessment. However, because of transfusion-induced infectious diseases, the safety of serum products is a serious concern. In this context, serum products acquired from patients themselves are the most ideal tracer. However, the development of rapid separation and easy clinical labeling methods is not yet well established. Under such situation, products from the same ethnic group or country are now recommended by the World Health Organization as an alternative preparation. This article describes the on-site preparation of Tc-99m HSA from locally supplied serum products. Different formulations were prepared and the labeling efficiency and stability were examined. Radio-labeling efficiencies were more than 90% in all preparation protocols, except for one that omitted the stannous solution. The most cost-effective protocol contained HSA 0.1 mg, treated with stannous fluoride 0.2 mg, and mixed with Tc-99m pertechnetate 30 mCi. A biodistribution study was performed in rats using a gamma camera immediately after intravenous administration of radiolabeled HSA. Tissue/organ uptake was obtained by measuring the radioactivity in organs after sacrificing the rats at timed intervals. The biologic half-life was about 32 min, determined from sequential venous blood collections. These data indicate that our preparation of Tc-99m HSA is useful and potentially applicable clinically. In addition, this on-site preparation provides the possibility of labeling a patient's own serum for subsequent clinical application. (author)

  6. Use of new tandem cation/anion exchange system with clinical-scale generators provides high specific volume solutions of technetium-99m and rhenium-188

    International Nuclear Information System (INIS)

    Knapp, F.F. Jr.; Beets, A.L.; Mirzadeh, S.; Guhlke, S.

    1998-01-01

    In this paper we describe the first application of our simple and inexpensive post-elution tandem cation/anion exchange column system which is based on generator elution with salts of weak acids such as ammonium acetate instead of saline solution to provide very high specific volume solutions of technetium-99m and rhenium-188 from clinical-scale molybdenum-99/technetium-99m generator prepared from low specific activity (n,y) molybdenum-99, and tungsten-188/rhenium-188 generators, respectively. Initial passage of the bolus through a strong cation exchange cartridge converts the ammonium acetate to acetic acid which is essentially not ionized at the acidic pH, allowing specific subsequent amine-type (QMA SepPak TM ) anion exchange cartridge column trapping of the microscopic levels of the pertechnetate or perrhenate. Subsequent elution of the anion cartridge with a small volume ( 500 mCi/mL) from the alumina-based tungsten-188/rhenium-188 generator. (author)

  7. Evaluation of technetium-99m/rhenium labelled nucleoside analogues as potential radiotracers in oncology[Dissertation 17173

    Energy Technology Data Exchange (ETDEWEB)

    Desbouis, D

    2007-07-01

    Over the last decade, suicide gene therapy has emerged as a very promising method to treat cancer. This therapy consists of introducing new genetic material into the nucleus of cancer cells so that they express a therapeutic protein. The protein leads to a therapeutic effect upon interaction with a prodrug. The most widely used system is the combination of the enzyme Herpes Simplex Virus Thymidine Kinase of type 1 (HSV1-TK) with the nontoxic antiviral prodrug gancyclovir. The efficiency of protein expression is crucial for a successful therapy. Several Positron Emission Tomography (PET) tracers such as 9-[4-[{sup 18}F]fluoro-3-(hydroxymethyl)butyl]guanine [{sup 18}F]FHBG) or [{sup 124}I]iodo-2'-fluoro-2'-deoxy-l-{beta}-D-arabino-furanosyluracil ({sup 124}I]FIAU) have been shown to be suitable probes for reporting HSV1-TK expression. One aspect of this work was to develop Single Photon Emission Tomography (SPET) reporter probes based on the inexpensive technetium-99m whose physical properties are well-suited for diagnosis (t{sub 1/2} = 6.02 h; E{sub {gamma}} = 140 keV). A series of complexes was prepared by derivatizing the precursor 5'-amino-5'-deoxythymidine at position N5' in order to introduce spacers of various lengths ({approx} 0-30 aangstroem) carrying tridentate metal chelating entities such as iminodiacetic acid and picolylamine-N-monoacetic acid. The nucleoside derivatives were reacted with the precursors [ReBr{sub 3}(CO){sub 3}]{sup 2-} and [{sup 99m}Tc(OH{sub 2}){sub 3}(CO){sub 3}]{sup +} to form water-stable organometallic thymidine complexes. Unexpectedly, most of the compounds showed no inhibition of HSV1-TK but a mixed inhibition of the human cytosolic thymidine kinase with K{sub iu} values ranging from 4.4-334 {mu}M. Competitive inhibition of HSV1-TK was only observed for the thymidine analogue in which the base and the metal core were separated by a spacer of approximately 30 aangstroem length (K{sub i} = 16.3 {+-} 4.6 {mu}M

  8. Retention of99mTc-sulfur calloid in the Kidneys

    International Nuclear Information System (INIS)

    Calegaro, J.U.M.; Gomes, E.F.; Carvalho, A.C.M. de; Ulyssea, R.

    1987-01-01

    A case of sulfur colloid retention in the kidneys of a patient with hepatic cirrosis and congestive cardiac failure during hepatic scintigraphy. The literature, summarizing all conditions in that this phenomenon occurs is revised and the probable mechanisms of action are discussed. (author) [pt

  9. Technetium 99m methylene diphosphonate bone scanning in osteoarthritic hands

    International Nuclear Information System (INIS)

    Buckland-Wright, J.C.; Lynch, J.A.; Macfarlane, D.G.; Homoeopathic Hospital, Tunbridge; Fogelman, I.; Emery, P.

    1991-01-01

    In this prospective study, the radiological features characteristic of osteoarthritis of the hand were compared with the radionuclide bone scan images. A total of 32 patients was assessed at 6-monthly intervals for 18 months. Microfocal radiographs were taken at each visit. The high magnification and resolution of this technique permitted direct measurement of joint space width, subchondral sclerosis, osteophyte number and area and juxta-articular radiolucency area for each joint in the hand. Four-hour technetium 99m methylene diphosphonate bone scans were taken at 0 and 12 months and the activity of tracer uptake at each joint scored. The latter was compared with each X-radiographic feature at every visit and the changes between visits analysed. The scan scores did not correlate with any of the X-radiographic features other than osteophyte size. During the study the size of growing and remodelling osteophytes increased significantly at joints with raised or increased isotope uptake. (orig.)

  10. Technetium 99m methylene diphosphonate bone scanning in osteoarthritic hands

    Energy Technology Data Exchange (ETDEWEB)

    Buckland-Wright, J.C.; Lynch, J.A. (United Medical and Dental Schools of Guy' s and Saint Thomas' , London (UK). Dept. of Anatomy); Macfarlane, D.G. (United Medical and Dental Schools of Guy' s and Saint Thomas' , London (UK). Dept. of Anatomy Homoeopathic Hospital, Tunbridge (UK). Dept. of Rheumatology); Fogelman, I. (United Medical and Dental Schools of Guy' s and Saint Thomas' , London (UK). Dept. of Nuclear Medicine); Emery, P. (United Medical and Dental Schools of Guy' s and Saint Thomas' , London (UK). Dept. of Rheumatology)

    1991-01-01

    In this prospective study, the radiological features characteristic of osteoarthritis of the hand were compared with the radionuclide bone scan images. A total of 32 patients was assessed at 6-monthly intervals for 18 months. Microfocal radiographs were taken at each visit. The high magnification and resolution of this technique permitted direct measurement of joint space width, subchondral sclerosis, osteophyte number and area and juxta-articular radiolucency area for each joint in the hand. Four-hour technetium 99m methylene diphosphonate bone scans were taken at 0 and 12 months and the activity of tracer uptake at each joint scored. The latter was compared with each X-radiographic feature at every visit and the changes between visits analysed. The scan scores did not correlate with any of the X-radiographic features other than osteophyte size. During the study the size of growing and remodelling osteophytes increased significantly at joints with raised or increased isotope uptake. (orig.).

  11. Scintigraphic imaging with technetium-99M-labelled ceftizoxime is a reliable technique for the diagnosis of deep sternal wound infection in rats

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Paulo Henrique Nogueira; Diniz, Simone Odilia Fernandes; Cardoso, Valbert Nascimento; Tarabal, Bernardo; Takenaka, Isabella; Braga, Otavio; Vidigal, Paula Vieira Teixeira; Gelape, Claudio Leo; Araujo, Ivana Duval, E-mail: phnc@uol.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil)

    2015-07-01

    Purpose: to evaluate whether scintigraphy with technetium-99m-labeled ceftizoxime ({sup 99m}Tc-CFT) can differentiate mediastinitis from aseptic inflammation associated with sternotomy. Methods: twenty female Wistar rats were randomly distributed into four groups: S (control) -partial upper median sternotomy with no treatment; SW (control) - sternotomy and treatment of sternal wounds with bone wax; SB - sternotomy and infection with Staphylococcus aureus; SWB - sternotomy with bone wax treatment and bacterial infection. Scintigraphy with {sup 99m}Tc-CFT was performed eight days after surgery and images were collected 210 and 360 min after infusion of the radiopharmaceutical. Results: no animals exhibited clinical signs of wound infection at the end of the experiment, although histological data verified acute inflammatory response in those experimentally infected with bacteria. Scintigraphic images revealed that tropism of {sup 99m}Tc-CFT to infected sternums was greater than to their non-infected counterparts. Mean counts of radioactivity in bacteria-infected sternal regions (SB and SWB) were significantly higher (p = 0.0007) than those of the respective controls (S and SW).Conclusion: scintigraphy with technetium-99m-labeled ceftizoxime is a method that can potentially detect infection post sternotomy and differentiate from aseptic inflammation in animals experimentally inoculated with S. aureus (author)

  12. Further optimisation of 99mTc-Nanocoll sentinel node localisation in carcinoma of the breast by improved labelling

    International Nuclear Information System (INIS)

    Gommans, G.M.M.; Dongen, A. van; Schors, T.G. van der; Boer, R.O.; Gommans, E.; Visser, J.F.M.; Waard, J.W.D. de; Clarijs, W.W.J.; Bos, J. van de

    2001-01-01

    The sentinel node (SLN) procedure has gained widespread acceptance for the axillary staging of patients who present with carcinoma of the breast. A first series of 21 patients were imaged 2 and 4 h after the injection of technetium-99m colloidal albumin. Preoperatively, axillary foci were located scintigraphically and with a hand-held gamma probe that was also used to detect the radiolabelled nodes 22 h later in the operating theatre. In a high percentage of our first series it was difficult to localise the sentinel node owing to a low count rate ex vivo. The aim of this study was to facilitate the detection of sentinel nodes by improving the count rate by the use of higher specific concentrations of 99m Tc-colloidal albumin, with increased radiochemical labelling efficiency and stability. In vitro tests were performed to establish the radiochemical labelling efficiency and stability of different concentrations of 99m Tc-colloidal albumin. Concentrations of 2.5, 10, 20, 25, 30, 37 and 50 MBq 99m Tc/μg colloidal albumin (Nanocoll) were prepared under nitrogen and in vacuum. The quality of the solutions was assessed by testing the radiochemical labelling efficiency and stability after 0.5, 2, 5, 8 and 24 h. The particle size of colloidal albumin was tested by dynamic light scattering at 30.2 , 62.6 and 90.0 angles. Following the results of the in vitro studies, higher concentrations of 99m Tc-colloidal albumin were used in vivo in a further series of 98 patients. For labelling under nitrogen, a maximum acceptable concentration of 10 MBq/μg was found, which complies with the specifications of the manufacturer. By preparing the labelling in vacuum vials, a 2.5 times greater radiochemical labelling efficiency over the entire period was achieved, and a significant improvement (P 99m Tc-colloidal albumin, which facilitated the detection of the SLN by the gamma probe during surgery. (orig.)

  13. Active and passive vectorization of technetium99m and 188rhenium radiopharmaceuticals for medical imaging and radiotherapy

    International Nuclear Information System (INIS)

    Lepareur, N.

    2003-11-01

    Research for new molecules for nuclear medicine is a field in constant development. Over the past few years, development of new radiopharmaceuticals for radiotherapy has renewed interest for rhenium chemistry. Indeed, its two isotopes 186 Re and 188 Re, owing to their ideal properties and their similitude with 99m Tc, which is widely used as a radiotracer for diagnostic imaging, seem very promising for the preparation of radiopharmaceuticals. In the first part of this manuscript, the synthesis of rhenium and technetium-99 complexes, [M(RPhCS3)2(RPhCS2)] (M = Re, Tc), is described. The preparation of technetium 99m based radiopharmaceuticals, analogues to the pondered complexes, is also described. The stability/reactivity of these complexes has been studied by exchange reactions with potential ligands, specially dithiocarbamates, and also by UV-visible absorption spectroscopy and thermogravimetry. The reactivity of the complexes towards dithiocarbamates leads to the possibility to bind biomolecules to the metallic core, via the dithiocarbamate moiety. This method represents a potential alternative to current ones using the so-called bifunctional approach. In the second part of this manuscript, a new kit formulation for the 188 Re labeling of lipiodol is described, using a complex analogous to those described in the previous part. The labeled oil is a potential cure for hepatocellular carcinoma. The in vitro and in vivo stability of this 188 Re-SSS lipiodol and of its analogue 99m Tc-SSS lipiodol has been studied, and also their in vivo behavior in healthy pigs. This study has shown the quasi-exclusive hepatic fixation of the radiopharmaceutical, and has proven its good stability. Its selectivity for tumors remains to be shown before trying it on humans. (author)

  14. Is Technetium-99m Sestamibi Imaging Able to Predict Pathologic Nonresponse to Neoadjuvant Chemotherapy in Breast Cancer? : A Meta-analysis Evaluating Current Use and Shortcomings

    NARCIS (Netherlands)

    Collarino, Angela; de Koster, Elizabeth J.; Valdés Olmos, Renato A.; de Geus-Oei, Lioe Fee; Pereira Arias-Bouda, Lenka M.

    2017-01-01

    Background: Interest in technetium-99m (99mTc)-sestamibi imaging for neoadjuvant chemotherapy (NAC) response monitoring in locally advanced breast cancer (LABC) is increasing but remains matter of discussion. The present study conducted a meta-analysis of the diagnostic performance of

  15. Synthesis, characterization and identification of the hexakis (trimethylphosphite) [Tc-99m]technetium(I) cation as a myocardial imaging agent

    International Nuclear Information System (INIS)

    Dean, R.T.; Adams, M.D.; Miller, F.W.; Robbins, M.S.; Wester, D.W.; White, D.H.

    1984-01-01

    Hexakis(trimethylphosphite)[Tc-99m]technetium(I), a monocationic complex, was synthesized for evaluation as a myocardial imaging agent. The above product was synthesized by reacting a methanolic solution of NaTcO/sub 4/ with trimethyl phosphite in an inert atmosphere at 100 0 for 30 min. Using the Tc-99 isotope, mg quantities were isolated for full characterization by precipitation from the reaction mixture using sodium tetraphenylborate. Recrystallization from methanol gave crystals of the tetraphenylborate salt. Elemental analyses, Tc-99 and P-31 NMR, mass spectra, X-ray photoelectron spectra, ir and X-ray crystal structure were all consistent with a hexacoordinate octahedral structure of the proposed monocation. The products formed from the Tc-99 isotope and the Tc-99m isotope were shown to be identical by HPLC using simultaneous radiometric and UV detection. The myocardial imaging properties of the title compound were evaluated by rat biodistribution and dog imaging. Five minutes after intravenous administration in rats, 3% dose/gm was in the heart with tissue ratios of heart/blood of 30, heart/liver of 4, heart/lung of 2. These compare to T1-201 values of 6% dose/gm in the heart with tissue ratios of heart/blood of 24, heart/liver of 6, heart/lung of 1. Imaging in an anesthetized dog revealed excellent myocardial uptake with persistent images through a 60 minute period. From these data the hexakis(trimethylphosphite)[Tc-99m]technetium(I) cation was identified as a myocardial imaging agent suitable for further evaluation

  16. Detection of gastrointestinal blood loss with 99mTc-labeled, heat-treated red blood cells

    International Nuclear Information System (INIS)

    Som, P.; Oster, Z.H.; Atkins, H.L.; Goldman, A.G.; Sacker, D.F.; Harold, W.H.; Fairchild, R.G.; Richards, P.; Brill, A.B.

    1981-01-01

    Studies in dogs showed that heat-treated 99mTc-labeled red blood cells (HT/RBC) afford a highly sensitive means of detecting gastrointetinal bleeding as low as 0.12 ml/min., which could not be seen with unheated 99mTc-RBC, 99mTc-sulfur colloid, or 99mTc-DTPA. In addition, as the right upper quadrant and epigastrium remained free of activity, only one fifth to one tenth of the dose of 99mTc was needed. The safety of HT/RBC in humans has been documented, and the experiments in dogs suggest that it may have advantages over other agents in detecting gastrointestinal bleeding

  17. Comparison of technetium-99m methoxyisobutylisonitrile and gallium-67 citrate scanning in the assessment of lymphomas

    International Nuclear Information System (INIS)

    Ziegels, P.; Nocaudie, M.; Huglo, D.; Deveaux, M.; Detourmignies, L.; Wattel, E.; Marchandise, X.

    1995-01-01

    The aim of this study was to compare the value of scintigraphy using technetium-99m methoxy-isobutylisonitrile (MIBI) with that of scintigraphy using gallium-67 citrate in the assessment of Hodgkin's disease and non-Hodgkin's lymphoma and to relate these results with those of CT scan and MRI. Fifty-eight patients were included either for a follow-up examination or for monitoring of their treatment. Twenty-three residual masses were studied. A whole-body scan was performed, followed by single-photon emission computed tomography (SPET) 20 min after injection of 740 MBq of 99m Tc-MIBI and 72 h after injection of 185 MBq of 67 Ga citrate. The overall sensitivity of 99m Tc-MIBI and 67 Ga citrate was 71% and 68%, respectively, and the overall specificity was 76% and 44%, respectively. For residual masses, the sensitivity was 44% with both tracers and the specificity was 80% with 99m Tc-MIBI and 53% with 67 Ga citrate. The positive predictive values were 85% and 68% and the negative predictive values were 59% and 44%, respectively. The signal-to-background ratio was 1.5 for 99m Tc-MIBI and 2 for 67 Ga citrate. At present, 99m Tc-MIBI cannot replace 67 Ga citrate in the assessment of lymphomas. (orig.)

  18. Radiolabeling of gemifloxacin with technetium-99m and biological evaluation in artificially Streptococcus pneumoniae infected rats

    International Nuclear Information System (INIS)

    Syed Qaiser Shah; Muhammad Rafiullah Khan

    2011-01-01

    In the current investigation complexation of the gemifloxacin (GIN) with technetium-99 m ( 99m Tc) and its biological evaluation in artificially Streptococcus pneumoniae (S. pneumoniae) infected rats was assessed as potential S. pneumoniae infection radiotracer. Radiochemically the 99m Tc-GIN complex was further analyzed in terms of stability in saline, in vitro stability in serum at 37 deg C, in vitro binding with S. pneumoniae and biodistribution in artificially S. pneumoniae (living and heat killed) infected rats. The complex was found 97.25 ± 0.25% radiochemically stable in saline at 30 min after reconstitution. The stability of the 99m Tc-GIN complex was decreased to 90.50 ± 0.20% within 240 min after reconstitution. In serum the 99m Tc-GIN complex showed stable profile with the appearance of 18.85% free tracer within 16 h of incubation. The 99m Tc-GIN complex showed saturated in vitro binding with S. pneumoniae after different intervals. Almost five fold uptake was observed in living S. pneumoniae infected muscle of the rats as compared to the inflamed and normal muscle. No significant difference in the uptake of heat killed S. pneumoniae infected, inflamed and normal muscles of the rats. The high RCP yield in saline, in vitro permanence in serum, in vitro binding with living S. pneumoniae and biodistribution in artificially S. pneumoniae infected rats we recommend the 99m Tc-GIN as potential S. pneumoniae infection radiotracer. (author)

  19. Use of technetium-99m-di-isopropyl-iminodiacetic acid imaging in the demonstration of a biliary-bronchial fistula

    Energy Technology Data Exchange (ETDEWEB)

    Savitch, I.; Esser, J.D.; Levin, J. (University of the Witwatersrand, Johannesburg (South Africa). Dept. of Nuclear Medicine); Krige, L.P.; Kew, M.C. (University of the Witwatersrand, Johannesburg (South Africa). Dept. of Medicine)

    1984-05-12

    A case is described in which technetium-99m-di-isopropyl-iminodiacetic acid imaging was used to trace the passage of bile from its site of leakage into an amoebic liver abscess, through a fistulous tract connecting the liver abscess with an abscess in the right lower lobe of the lung, and into the upper respiratory tract.

  20. Scintimammography with technetium-99m methoxyisobutylisonitrile: results of a prospective European multicentre trial

    Energy Technology Data Exchange (ETDEWEB)

    Palmedo, H.; Biersack, H.J. [Bonn Univ. (Germany). Dept. of Nucl. Med.; Lastoria, S. [Department of Nuclear Medicine, National Cancer Institute of Naples (Italy); Maublant, J. [Department of Nuclear Medicine, Centre Jean Perrin in Clermont Ferrand (France); Prats, E. [Department of Nuclear Medicine, University Hospital of Zaragoza (Spain); Stegner, H.E. [Department of Gynecology, University of Hamburg (Germany); Bourgeois, P. [Department of Nuclear Medicine, Hospital St. Pierre in Bruxelles (Belgium); Hustinx, R. [Department of Nuclear Medicine, University Hospital in Liege (Belgium); Hilson, A.J.W. [Department of Nuclear Medicine, NHS Trust Hospital in London (United Kingdom); Bischof-Delaloye, A. [Department of Nuclear Medicine, University of Lausanne (Switzerland)

    1998-04-01

    The aim of the trial was to determine the diagnostic accuracy of scintimmammography with technetium-99m methoxyisobutylisonitrile ({sup 99m}Tc-MIBI) in the detection of primary breast cancer and to verify its clinical usefulness. A total of 246 patients with a suspicious breast mass or positive mammogram were included in this prospective European multicentre trial. At 5 min and 60 min (optional) p.i. two lateral prone images were acquired for 10 min each; 30 min p.i. one anterior image was acquired for 10 min. There were 253 lesions (195 palpable and 58 non-palpable), in respect of which histology revealed 165 cancers and 88 benign lesions. Institutional and blinded read results were correlated to core laboratory histopathology results obtained during excisional biopsy. Diagnostic accuracy for the detection of breast cancer was calculated per lesion. The overall sensitivity and specificity of blinded read scintimammography were 71% and 69%, respectively. For palpable lesions, the sensitivity of blinded read and institutional read scintimammography was 83% and 91%, respectively. Sensitivity was not dependent on the density of the breast tissue. Invasive ductal and invasive lobular cancers showed similar sensitivity. The sensitivity and specificity of mammography were 91% and 42%, respectively, and did not depend on the tumour size. In 60% of false-negative mammograms, {sup 99m}Tc-MIBI was able to diagnose malignancy (true-positive). High-quality imaging with {sup 99m}Tc-MIBI has a high diagnostic accuracy for the detection of primary breast cancer. Used as a complementary method, scintimammography with {sup 99m}Tc-MIBI can help to diagnose breast cancer at an earlier stage in patients with dense breasts. (orig.) With 6 figs., 12 tabs., 55 refs.

  1. Scintigraphic evaluation of chronic cholecystitis with cholelithiasis using technetium-99m-labelled pyridoxylidene isoleucine

    International Nuclear Information System (INIS)

    Alp, E.; Bekdik, C.F.; Laleli, Y.; Ercan, M.T.

    1981-01-01

    Technetium-99m-labelled pyridoxylidene isoleucine was evaluated in normal subjects as a hepatobiliar scanning agent and in patients with chronic cholecystitis with cholelithiasis. In all the normals and patients the liver function tests (SGOT, SGPT, AP and serum bilirubin) were normal. Scintigraphic studies were performed at 5, 10, 15, 20, 25, 30 and 60 min after IV administration of the agent. In the normal group (seven subjects) liver was visualized at 5 min, the common bile duct and the gall bladder at 5-15 min and the bowel activity within 20 min. In the patient group (15 subjects) the liver and the common bile duct were visualized at the same time as in the normal group but the gall bladder was either visualized later or not at all. The results showed that chronic cholecystitis with cholelithiasis may be diagnosed with 87% accuracy using 99 Tcsup(m)-pyridoxylidene isoleucine cholescintigraphy. Scintigraphy with this agent has also superiority over roentgenologic examination in 20% of the cases. (author)

  2. Pharmaceutical grade sodium (99mTc) pertechnetate from 99Mo/99mTc-TCM-Autosolex generator

    International Nuclear Information System (INIS)

    Chattopadhyay, Sankha; Barua, Luna; Das, Sujata Saha

    2014-01-01

    Technetium-99m (T 1/2 = 6.02h; 140.51 keV (89%)) is the most useful radioisotope in diagnostic nuclear medicine. More than 80% of all diagnostic procedures done worldwide in nuclear medicine centre are performed with 99m Tc. Worldwide crisis of fission 99 Mo based generator in recent past had put the nuclear medicine fraternity in very harsh situation. In order to have an indigenous solution of this problem, we tried to develop a computer controlled semi automated 99 Mo/ 99m Tc generator using MEK solvent extraction technique, which utilizes abundantly available 99 Mo produced by (n,γ) reaction in BARC reactors. The aim of this work is to provide a more reliable, computer controlled module (TCM- AUTOSOLEX) for the recovery of pharmaceutical grade 99m Tc from low specific activity 99 Mo based on solvent extraction methodology

  3. Kinetics of hypodermically injected technetium-99m and correlation with cutaneous structures: an experimental study in dogs

    International Nuclear Information System (INIS)

    Kovacs, F.M.; Gotzens, V.; Garcia, A.; Garcia, F.; Mufraggi, N.; Prandi, D.; Setoain, J.; San Roman, F.

    1993-01-01

    We investigated the involvement of cutaneous structures in specific linear migration pathways of technetium-99 m pertechnetate hypodermically injected at points of low electrical resistance in the metacarpus of male beagles. Skin-deep incisions were made in the front or back legs on either the same side as the 99m Tc injection or on the opposite side. Incisions in the back legs did not affect the migration pattern. Incisions in the front legs before the injection of 99m Tc prevented tracer migration. After the injection of 99m Tc, incisions in the front contralateral leg caused sudden cessation of the migration, while incisions in the ipsilateral leg caused immediate disappearance of the pathway previously observed. Radioactivity was not detected in flaps obtained from the skin overlying the migration pathway or from the corresponding area of the contralateral leg. In conclusion, the specific linear migration pathways of 99m Tc hypodermically injected at points of low electrical resistance cannot be explained by any known biological function. Although the migration of 99m Tc does not seem to be strongly linked to any cutaneous structure, the skin overlying the radioactive pathway and the corresponding area of the contralateral leg must be intact if tracer migration is to take place. (orig.)

  4. Assessment of the effect of phytic acid on the labeling of blood cells and plasma proteins with Technetium-99m

    International Nuclear Information System (INIS)

    Lima-Filho, Guilherme L.; Freitas, Rosimeire S.; Moreno, Silvana R.F.; Boasquevisque, Edson M.; Bernardo-Filho, Mario; Lima, Glaydes M.T.; Catanho, Maria T.J.A.

    2002-01-01

    Blood elements labeled with technetium-99m ( 99m Tc) have been used in various procedures in nuclear medicine. We have investigated if phytic acid (PHY) could alter the labeling of blood elements with 99m Tc. Blood was incubated with different concentrations of PHY. Stannous chloride and 99m Tc, as sodium pertechnetate, were added. Blood was centrifuged and plasma (P) and blood cell (BC) were isolated. Samples of P and BC were also precipitated with trichloroacetic acid and centrifuged, and insoluble (IF) and soluble (SF) fractions were separated. The percentages of radioactivity (%ATI) in BC, IF-P and IF-BC were calculated. The %ATI decreased significantly (p 99m Tc with possible undesirable effects, it is relevant to verify the necessity to repeat the examination and to evaluate the increase of the radiation dose to the patient. (author)

  5. Phantom evaluation of simultaneous thallium-201/technetium-99m acquisition in single-photon emission tomography

    International Nuclear Information System (INIS)

    Cao Zongjian; Chen, C.C.; Maunoury, C.; Holder, L.E.; Abraham, T.C.; Tehan, A.

    1996-01-01

    This study investigated downscatter effects in cardiac single-photon emission tomographic studies with simultaneous thallium-201/technetium-99m acquisition, and evaluated a previously proposed subtraction technique for downscatter compensation. Ten studies were carried out with different defect sizes and locations and varying activity distributions using four energy windows: 70±10% keV, 140±10% keV, 100±10% KeV, and 103±16% keV. The subtraction technique used the 100- or 103-keV data to remove scattered 99m Tc counts from the 70-keV data. The size and contrast of infarcts in the dual-isotope 70-keV image were artificially decreased compared to those in the 140-keV image, caused by scattered 99m Tc counts that were comparable to the primary 201 Tl counts in the 70-keV window. The subtraction technique produced larger defects and more heterogeneous activity in the myocardial wall in dual-isotope 70-keV images compared to the corresponding 201 Tl-only images. These artifacts were caused by the markedly different spatial distributions of scattered 99m Tc counts in the 100-keV (or 103-keV) window as compared with the 70-keV window. It is concluded that scattered 99m Tc photons may cause overestimation of ischemia and myocardial viability in simultaneous dual-isotope patient studies. The proposed subtraction technique was inaccurate and produced image artifacts. Adequate downscatter compensation methods must be developed before applying simultaneous 201 Tl/ 99m Tc acquisition in clinical practice. (orig.). With 6 figs., 3 tabs

  6. Technetium-99m-HMPAO SPECT in patients with hemiconvulsions followed by Todd`s paralysis

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, M.; Sejima, Hitoshi; Ozasa, Hiroshi; Yamaguchi, Seiji [Department of Pediatrics, Shimane Medical University, 89-1 Enya-cho, Izumo, Shimane 693 (Japan)

    1998-02-01

    We performed technetium-99m-hexamethylpropylene- amineoxime (Tc-HMPAO) single photon emission computed tomography in two patients with prolonged hemiconvulsions followed by transient hemiparesis (Todd`s paralysis). In both cases, a prolonged post-ictal cerebral hyperperfusion state of approximately 24 h was observed, even after the neurological deficits had resolved. The cerebral hyperperfusion in both cases was of much longer duration than that in previously reported cases of single and uncomplicated focal seizures. The prolonged cerebral hyperperfusion might have been due to impairment of the cerebrovascular autoregulation in seizures followed by Todd`s paralysis. (orig.) With 2 figs., 9 refs.

  7. Labelling of 5-ethyl-5-phenylbarbituric acid with Technetium-99m: biodistribution study in Swiss mice

    International Nuclear Information System (INIS)

    Simoes, Susana B.E.; Oliveira, Marcia B.N. de; Gutfilen, Bianca; Bernardo-Filho, Mario; Alves, Andreia Coelho; Machado-Silva, Jose R.

    1996-01-01

    The 5-ethyl-5-phenylbarbituric acid (phenobarbital) is used as a sedative, hypnotic and anticonvulsant drug. We decided to label it with technetium-99m. In order to determine the optimal conditions, different concentrations of this drug were incubated with various stannous chloride solutions. Then, 99m Tc was added and chromatography was performed using 0.9% NaCl solution, acetone and n-butyl alcohol as the mobile phase. Using a solution of 0.01 mg/ml stannous chloride and 1.0 mg/ml phenobarbital over 92% of the radioactivity bound to phenobarbital 99m Tc-phenobarbital. In the biodistribution study, 99m Tc-phenobarbital was administered in mice intraperitoneal. The main uptake of the labeled drug was in the liver, blood, kidneys, spleen and stomach. The phenobarbital is also used as anesthetic drug in animals. Earlier studies confirm that this drug can dislocate the adult worms of Schistosoma mansoni to mesenteric vein towards the liver and portal vein, so that we used infected animals, radioactivity was not found in isolated worms and we can conclude that the phenobarbital has an indirect action in relation to the displacement of the worms. (author)

  8. Active and passive vectorization of technetium{sup 99m} and {sup 188}rhenium radiopharmaceuticals for medical imaging and radiotherapy; Vectorisations active et passive de radiopharmaceutiques du technetium-99m et du rhenium-188 pour l'imagerie medicale et la therapie

    Energy Technology Data Exchange (ETDEWEB)

    Lepareur, N

    2003-11-15

    Research for new molecules for nuclear medicine is a field in constant development. Over the past few years, development of new radiopharmaceuticals for radiotherapy has renewed interest for rhenium chemistry. Indeed, its two isotopes {sup 186}Re and {sup 188}Re, owing to their ideal properties and their similitude with {sup 99m}Tc, which is widely used as a radiotracer for diagnostic imaging, seem very promising for the preparation of radiopharmaceuticals. In the first part of this manuscript, the synthesis of rhenium and technetium-99 complexes, [M(RPhCS3)2(RPhCS2)] (M = Re, Tc), is described. The preparation of technetium{sup 99m} based radiopharmaceuticals, analogues to the pondered complexes, is also described. The stability/reactivity of these complexes has been studied by exchange reactions with potential ligands, specially dithiocarbamates, and also by UV-visible absorption spectroscopy and thermogravimetry. The reactivity of the complexes towards dithiocarbamates leads to the possibility to bind biomolecules to the metallic core, via the dithiocarbamate moiety. This method represents a potential alternative to current ones using the so-called bifunctional approach. In the second part of this manuscript, a new kit formulation for the {sup 188}Re labeling of lipiodol is described, using a complex analogous to those described in the previous part. The labeled oil is a potential cure for hepatocellular carcinoma. The in vitro and in vivo stability of this {sup 188}Re-SSS lipiodol and of its analogue {sup 99m}Tc-SSS lipiodol has been studied, and also their in vivo behavior in healthy pigs. This study has shown the quasi-exclusive hepatic fixation of the radiopharmaceutical, and has proven its good stability. Its selectivity for tumors remains to be shown before trying it on humans. (author)

  9. Active and passive vectorization of technetium{sup 99m} and {sup 188}rhenium radiopharmaceuticals for medical imaging and radiotherapy; Vectorisations active et passive de radiopharmaceutiques du technetium-99m et du rhenium-188 pour l'imagerie medicale et la therapie

    Energy Technology Data Exchange (ETDEWEB)

    Lepareur, N

    2003-11-15

    Research for new molecules for nuclear medicine is a field in constant development. Over the past few years, development of new radiopharmaceuticals for radiotherapy has renewed interest for rhenium chemistry. Indeed, its two isotopes {sup 186}Re and {sup 188}Re, owing to their ideal properties and their similitude with {sup 99m}Tc, which is widely used as a radiotracer for diagnostic imaging, seem very promising for the preparation of radiopharmaceuticals. In the first part of this manuscript, the synthesis of rhenium and technetium-99 complexes, [M(RPhCS3)2(RPhCS2)] (M = Re, Tc), is described. The preparation of technetium{sup 99m} based radiopharmaceuticals, analogues to the pondered complexes, is also described. The stability/reactivity of these complexes has been studied by exchange reactions with potential ligands, specially dithiocarbamates, and also by UV-visible absorption spectroscopy and thermogravimetry. The reactivity of the complexes towards dithiocarbamates leads to the possibility to bind biomolecules to the metallic core, via the dithiocarbamate moiety. This method represents a potential alternative to current ones using the so-called bifunctional approach. In the second part of this manuscript, a new kit formulation for the {sup 188}Re labeling of lipiodol is described, using a complex analogous to those described in the previous part. The labeled oil is a potential cure for hepatocellular carcinoma. The in vitro and in vivo stability of this {sup 188}Re-SSS lipiodol and of its analogue {sup 99m}Tc-SSS lipiodol has been studied, and also their in vivo behavior in healthy pigs. This study has shown the quasi-exclusive hepatic fixation of the radiopharmaceutical, and has proven its good stability. Its selectivity for tumors remains to be shown before trying it on humans. (author)

  10. Liver scintigraphy with sup(99m)Tc-Sn-colloid

    International Nuclear Information System (INIS)

    Suzuki, Masaaki

    1976-01-01

    Basic and clinical studies of sup(99m)Tc-Sn-colloid (Tc-Sn-C) were made on liver scintigraphy for comparison with 198 Au-colloid in blood clearance, liver accumulation, and spleen imaging strength. Tc-Sn-C was excellent in ease of sterilization, simplicity of preparation, reduction in the exposure dose for the examiner, labeling rate, and stability, and it was effective as a drug for liver scintigraphy. The blood clearance T1/2 can be an indicator for the blood flow rate in the liver, similarly to the Au-C method. Although a decrease in the liver radioactivity after liver accumulation was observed, it was not thought to affect liver scintigraphy. A clear shadow of the liver was obtained in all cases, and there seemed to be no differences between the commercially prepared Tc-Sn-C and the Tc-Sn-C which must be prepared each time. The spleen imaging strength was thought to be effective as a supplementary diagnosis for splenic diseases. No allergic symptoms appeared immediately after examination. (Chiba, N.)

  11. Quantitative comparison of technetium-99m tetrofosmin and thallium-201 images of the thyroid and abnormal parathyroid glands

    International Nuclear Information System (INIS)

    Giordano, A.; Meduri, G.; Calcagni, M.L.; Marozzi, P.; Ficola, U.; Vaccaro, A.; Rubini, G.; Attard, M.; Li Puma, M.; Ricci, R.; Corsello, S.

    1999-01-01

    The aim of the study was to quantitatively compare the scintigraphic images of the thyroid and abnormal parathyroid glands obtained with technetium-99m tetrofosmin and thallium-201 in patients with hyperparathyroidism. Forty-six patients with hyperparathyroidism underwent 201 Tl (74 MBq), 99m Tc-pertechnetate (74 MBq) and 99m Tc-tetrofosmin (555-740 MBq) scintigraphy in a single session. Image analysis included the computation of the thyroid/background ratio in the whole study population and the parathyroid/background ratio, parathyroid/thyroid ratio and diagnostic sensitivity in 17 patients who underwent parathyroid surgery. The pertechnetate subtraction technique was used. 201 Tl and 99m Tc-tetrofosmin showed a similar thyroid/background ratio (1.79±0.41 and 1.81±0.47, respectively, P=NS); however, 99m Tc-tetrofosmin showed a higher parathyroid/background ratio than 201 Tl (2.06±0.54 vs 1.79± 0.50, P=0.007). Despite the superior quality of 99m Tc-tetrofosmin images, both tracers showed identical sensitivity in detecting enlarged parathyroid glands in patients with primary hyperparathyroidism (89%) and in those with secondary hyperparathyroidism (50%). (orig.)

  12. Use of a new tandem cation/anion exchange system with clinical-scale generators provides high specific volume solutions of technetium-99m and rhenium-188

    International Nuclear Information System (INIS)

    Knapp, F.R. Jr.; Beets, A.L.; Mirzadeh, S.; Guhlke, S.; Univ. of Bonn

    1998-03-01

    In this paper the authors describe the first application of a simple and inexpensive post elution tandem cation-anion exchange column system which is based on generator elution with salts of weak acids such as ammonium acetate instead of saline solution to provide very high specific volume solutions of technetium-99m and rhenium-188 from clinical scale molybdenum-99/technetium-99m generator prepared from low specific activity (n,y) molybdenum-99, and tungsten-188/rhenium-188 generators, respectively. Initial passage of the bolus through a strong cation exchange cartridge converts the ammonium acetate to acetic acid which is essentially not ionized at the acidic pH, allowing specific subsequent amine type (QMA SepPak trademark) anion exchange cartridge column trapping of the microscopic levels of the pertechnetate or perrhenate. Subsequent elution of the anion cartridge with a small volume ( 500 mCi/mL) from the alumina-based tungsten-188/rhenium-188 generator

  13. Myocardial perfusion scintigraphy with technetium 99m-MIBI in the diagnosis of coronary artery disease in women

    International Nuclear Information System (INIS)

    Peix, C. Amalia; Chacon, Deylis; Llerena, Lorenzo; Torres, Maritza; Garcia, Ernesto Javier; Cabrera, Lazaro Omar

    2006-01-01

    The results of technetium 99 m - methoxy-isobutyl-isonitrile scintigraphy in a one-day protocol: rest - physical or combined stress bicycle plus endovenoous dipyridamole were compared with those of coronary angiography in 20 women referred for the evaluation of pre cordial pain and of the usefulness of myocardial perfusion scintigraphy. The uptake of the radio drug under stress and at rest varied from 93 + - 9 to 94 + - 7 % in the 204 segments with normal uptake under stress, from 67 He articulates it analyzes the reasons or utility of the employment of the radioactive iodine in the diagnosis and treatment of the thyroid affections + - 9 to 75 + - 17 % in the 89 with moderate reduction, and from 33 + - 9 to 64 + - 28 % in the 27 with severe reduction. The qualitative and quantitative uptake analyses coincided in 18 patients. The perfusion scintigraphy and the angiography agreed in 70 % of the patients. It was concluded that the myocardial perfusion scintigraphy with technetium 99 -MIBI contributes to the diagnosis of the coronary artery disease in women

  14. Detecting Myocardial Ischemia With 99mTechnetium-Tetrofosmin Myocardial Perfusion Imaging in Ischemic Stroke.

    Science.gov (United States)

    Giannopoulos, Sotirios; Markoula, Sofia; Sioka, Chrissa; Zouroudi, Sofia; Spiliotopoulou, Maria; Naka, Katerina K; Michalis, Lampros K; Fotopoulos, Andreas; Kyritsis, Athanassios P

    2017-10-01

    To assess the myocardial status in patients with stroke, employing myocardial perfusion imaging (MPI) with 99m Technetium-tetrofosmin ( 99m Tc-TF)-single-photon emission computed tomography (SPECT). Fifty-two patients with ischemic stroke were subjected to 99m Tc-TF-SPECT MPI within 1 month after stroke occurrence. None of the patients had any history or symptoms of coronary artery disease or other heart disease. Myocardial perfusion imaging was evaluated visually using a 17-segment polar map. Myocardial ischemia (MIS) was defined as present when the summed stress score (SSS) was >4; MIS was defined as mild when SSS was 4 to 8, and moderate/severe with SSS ≥9. Patients with SSS >4 were compared to patients with SSS SSS >9 were compared to patients with SSS SSS, with the oldest age exhibiting the highest SSS ( P = .01). The association of age with SSS remained statistically significant in the multivariate analysis ( P = .04). The study suggested that more than half of patients with stroke without a history of cardiac disease have MIS. Although most of them have mild MIS, we suggest a thorough cardiological evaluation in this group of patients for future prevention of severe myocardial outcome.

  15. Technetium-99m labelled antimicrobial peptides discriminate between bacterial infections and sterile inflammations

    International Nuclear Information System (INIS)

    Welling, M.M.; Pauwels, E.K.J.; Paulusma-Annema, A.; Nibbering, P.H.; Balter, H.S.

    2000-01-01

    The aim of this study was to select technetium-99m labelled peptides that can discriminate between bacterial infections and sterile inflammations. For this purpose, we first assessed the binding of various 99m Tc-labelled natural or synthetic peptides, which are based on the sequence of the human antimicrobial peptide ubiquicidin (UBI) or human lactoferrin (hLF), to bacteria and to leucocytes in vitro. In order to select peptides that preferentially bind to bacteria over host cells, radiolabelled peptides were injected into mice intraperitoneally infected with Klebsiella pneumoniae (K. pneumoniae) and the amount of radioactivity associated with the bacteria and with the leucocytes was quantitated. The next phase focussed on discrimination between bacterial infections and sterile inflammatory processes using 99m Tc-labelled peptides in mice intramuscularly infected with various bacteria (e.g. multi-drug-resistant Staphylococcus aureus) and in animals that had been injected with lipopolysaccharides (LPS) of bacterial origin to create a sterile inflammatory process. Also, we studied the distribution of 99m Tc-labelled UBI 29-41 and UBI 18-35 in rabbits having an experimental thigh muscle infection with K. pneumoniae and in rabbits injected with LPS. Based on the results of our in vitro and in vivo binding assays, two peptides, i.e. UBI 29-41 and UBI 18-35, were selected as possible candidates for infection imaging. The radiolabelled peptides can detect infections with both gram-positive and gram-negative bacteria in mice as early as 5-30 min after injection, with a target-to-non-target (T/NT) ratio between 2 and 3; maximum T/NT ratios were seen within 1 h after injection. In rabbits, high T/NT ratios (>5) for 99m Tc-labelled UBI 29-41 were observed from 1 h after injection. No accumulation of the selected 99m Tc-labelled UBI-derived peptides was observed in thighs of mice and rabbits previously injected with LPS. Scintigraphic investigation into the biodistribution of

  16. Technetium-99m labelled antimicrobial peptides discriminate between bacterial infections and sterile inflammations

    Energy Technology Data Exchange (ETDEWEB)

    Welling, M.M.; Pauwels, E.K.J. [Dept. of Radiology, Leiden University Medical Center (LUMC) (Netherlands); Paulusma-Annema, A.; Nibbering, P.H. [Dept. of Infectious Diseases, Leiden University Medical Center (Netherlands); Balter, H.S. [Centro Investigaciones Nucleares, Univ. of the Republic Uruguay, Montevideo (Uruguay)

    2000-03-01

    The aim of this study was to select technetium-99m labelled peptides that can discriminate between bacterial infections and sterile inflammations. For this purpose, we first assessed the binding of various {sup 99m}Tc-labelled natural or synthetic peptides, which are based on the sequence of the human antimicrobial peptide ubiquicidin (UBI) or human lactoferrin (hLF), to bacteria and to leucocytes in vitro. In order to select peptides that preferentially bind to bacteria over host cells, radiolabelled peptides were injected into mice intraperitoneally infected with Klebsiella pneumoniae (K. pneumoniae) and the amount of radioactivity associated with the bacteria and with the leucocytes was quantitated. The next phase focussed on discrimination between bacterial infections and sterile inflammatory processes using {sup 99m}Tc-labelled peptides in mice intramuscularly infected with various bacteria (e.g. multi-drug-resistant Staphylococcus aureus) and in animals that had been injected with lipopolysaccharides (LPS) of bacterial origin to create a sterile inflammatory process. Also, we studied the distribution of {sup 99m}Tc-labelled UBI 29-41 and UBI 18-35 in rabbits having an experimental thigh muscle infection with K. pneumoniae and in rabbits injected with LPS. Based on the results of our in vitro and in vivo binding assays, two peptides, i.e. UBI 29-41 and UBI 18-35, were selected as possible candidates for infection imaging. The radiolabelled peptides can detect infections with both gram-positive and gram-negative bacteria in mice as early as 5-30 min after injection, with a target-to-non-target (T/NT) ratio between 2 and 3; maximum T/NT ratios were seen within 1 h after injection. In rabbits, high T/NT ratios (>5) for {sup 99m}Tc-labelled UBI 29-41 were observed from 1 h after injection. No accumulation of the selected {sup 99m}Tc-labelled UBI-derived peptides was observed in thighs of mice and rabbits previously injected with LPS. Scintigraphic investigation

  17. Accuracy of 99Molybdenum assays in /sup 99m/Technetium solutions

    International Nuclear Information System (INIS)

    Williams, C.C.; Kereiakes, J.G.; Grossman, L.W.

    1981-01-01

    A study was performed to determine the accuracy of 99 Mo measurements using three commercial dose calibrators with their 99 Mo assay shields. One 99 Mo assay shield allowed excessive penetration by the lower energy /sup 99m/Tc photons, resulting in the calibrator's falsely high interpretation of the activity of 99 Mo present in the high-activity /sup 99m/Tc eluates. All three calibrators performed adequately with a National Bureau of Standards 99 Mo standard in equilibrium with /sup 99m/Tc. By using low-activity aliquots of 99 Mo and /sup 99m/Tc, a low-level linearity test was performed. Only one of the calibrators was found to reflect accurately the activity of 99 Mo present under all conditions tested

  18. Detection of axillary lymph node metastases in breast carcinoma by technetium-99m sestamibi breast scintigraphy, ultrasound and conventional mammography

    International Nuclear Information System (INIS)

    Lam, W.W.M.; Yang, W.T.; Chan, Y.L.; Stewart, I.E.T.; Metreweli, C.; King, W.

    1996-01-01

    Axillary lymph node status is important in the staging of breast carcinoma. To evaluate the accuracy of technetium-99m sestamibi breast scintigraphy in detecting metastatic axillary lymph nodes as compared with other accepted imaging modalities, we performed 99m Tc-sestamibi breast scintigraphy, conventional mammography and ultrasound in 36 patients with primary untreated breast cardinoma. With histopathology as the gold standard, 99m Tc-sestamibi breast scintigraphy was found to yield true-positive results in 7 of 11 cases (64%) of axillary lymph nodes metastases and true-negative results in 18 of 20 cases (90%); it has an accuracy of 81%, a positive predictive value of 77.8% and a negative predicive value of 81.8%. (orig.)

  19. Assessment of the accumulation of technetium-99m labelled leukocytes in the treatment of the infections of vascular prosthesis

    International Nuclear Information System (INIS)

    Pupka, A.; Kaluza, G.; Skora, J.; Szyber, P.; Rynowiecka, M.

    2003-01-01

    The purpose of this is to evaluate the accumulation of technetium-99m-labelled leukocytes after change of vascular, dacron and infected prosthetic graft in arterial homo grafts harvested from multiorgan-procurement - with own computer program. In this paper 11 cases of aorto-ilio-femoral graft infection treated by the replacement of infected prosthesis with fresh, bifurcated, arterial homografts is presented. In all patients clinical investigations revealed vascular prosthesis infection with the rupture of vascular anastomoses between the prosthesis' branch and wall of artery that resulted with hemorrhage. The Duplex- Doppler ultrasound and the scintigraphy with use of technetium-labeled leucocytes were used in the diagnostic trial of infection and of the healing process of the arterial homografts.The area of the accumulation of 99m Tc labelled leukocytes was evaluated with own computer programs. Positive clinical effect was obtained in all patients.The regression of infection after in situ replacement of the synthetic prosthesis with homograft was presented with the scintigraphic examination: in these patients the area of leukocytes accumulation decreased from 34±3 cm 2 to 9±2cm 2 . The use of scintigraphy with 99m Tc labelled leukocytes to evaluate the healing process of the arterial homografts in therapy of the prosthetic graft is a the accumulation of leucocytes is facilitation in the monitoring of regression of infection. (author)

  20. Technetium 99m-labeled annexin v scintigraphy of platelet activation in vegetations of experimental endocarditis

    International Nuclear Information System (INIS)

    Rouzet, F.; Sarda-Mantel, L.; Le Guludec, D.; Rouzet, F.; Sarda-Mantel, L.; LeGuludec, D.; Rouzet, F.; Sarda-Mantel, L.; Le Guludec, D.; Hernandez, M.D.; Louedec, L.; Michel, J.B.; Hervatin, F.; Lefort, A.; Fantin, B.; Duval, X.; Duval, X.; Hernandez, M.D.

    2008-01-01

    Background: The pathophysiology of infective endocarditis involves a pathogen/host tissue interaction, leading to formation of infected thrombotic vegetations. Annexin V is a ligand of phosphatidyl-serines exposed by activated platelets and apoptotic cells. Because vegetations are platelet-fibrin clots in which platelet pro-aggregant activity is enhanced by bacterial colonization, we investigated the ability of annexin V labeled with technetium 99m Tc ( 99m Tc-ANX) to provide functional imaging of these vegetations in experimental models of infective endocarditis. This ability was assessed in rabbits and rats because of the different interest of these 2 species in preclinical analysis. Methods and Results: Non-bacterial thrombotic endocarditis was induced with the use of a catheter left indwelling through the aortic or tricuspid valve, and animals were injected with either a bacterial inoculum or saline. Scintigraphic investigations were performed 5 days later and showed a higher 99m Tc-ANX uptake by vegetations in infected versus non-infected animals (ratio,1.3 for in vivo acquisitions and 2 for autoradiography; P ≤ 0.0001 for all), whereas no significant uptake was present in controls. Right-sided endocarditis was associated with pulmonary uptake foci corresponding to emboli. Histological analysis of vegetations showed a specific uptake of 99m Tc-ANX at the interface between circulating blood and vegetation. In parallel, underlying myocardial tissue showed myocyte apoptosis and mucoid degeneration, without extracellular matrix degradation at this stage. Conclusions: 99m Tc-ANX is suitable for functional imaging of platelet-fibrin vegetations in endocarditis, as well as embolic events. 99m Tc-ANX uptake reflects mainly platelet activation in the luminal layer of vegetations. This uptake is enhanced by bacterial colonization. (authors)

  1. Quantitative exercise technetium-99m tetrofosmin myocardial tomography for the identification and localization of coronary artery disease

    International Nuclear Information System (INIS)

    Sullo, P.; Cuocolo, A.; Nicolai, E.; Cardei, S.; Nappi, A.; Squame, F.; Covelli, E.M.; Pace, L.; Salvatore, M.

    1996-01-01

    The aim of this study was to evaluate the accuracy of quantitative 1-day exercise-rest technetium-99m tetrofosmin tomography in the identification of patients with coronary artery disease (CAD) and in the detection of individual stenosed coronary vessels. Sixty-one patients with suspected CAD who underwent coronary angiography and 13 normal volunteers were studied. All patients were submitted to two i.v. injections of 99m Tc-tetrofosmin, one at peak exercise (370 MBq) and the other (1110 MBq) at rest 3 h after exercise (images 15-30 min after injection for both studies). All patients with CAD (≥50% luminal stenosis) (n=50) had an abnormal 99m Tc-tetrofosmin tomogram. Only one patient without significant coronary narrowing showed abnormal findings. Overall senstivity, specificity and diagnostic accuracy in the detection of individual stenosed vissels were 77%, 93% and 85%, respectively. Sensitivity and diagnostic accuracy in the identification of individuals stenosed coronary vessels were significantly higher (P 75%). (orig.)

  2. The use of technetium-99m-di-isopropyl-iminodiacetic acid imaging in the demonstration of a biliary-bronchial fistula

    International Nuclear Information System (INIS)

    Savitch, I.; Esser, J.D.; Levin, J.; Krige, L.P.; Kew, M.C.

    1984-01-01

    A case is described in which technetium-99m-di-isopropyl-iminodiacetic acid imaging was used to trace the passage of bile from its site of leakage into an amoebic liver abscess, through a fistulous tract connecting the liver abscess with an abscess in the right lower lobe of the lung, and into the upper respiratory tract

  3. Dynamic and scintigraphic studies of diffuse hepatic diseases using /sup 99m/Tc-Sn-phytate. Comparative analyses with /sup 198/Au-colloid

    Energy Technology Data Exchange (ETDEWEB)

    Akisada, M [Mitsui Memorial Hospital, Tokyo (Japan); Miyamae, T

    1975-09-01

    From March 1974 to May 1974, liver scintigraphies were performed at Mitsui Memorial Hospital. Three groups of patients were composed of: 24 of liver cirrhosis, 29 of chronic hepatitis and 30 of a normal control group. The mixture of 1.5 mCi of sup(99m)Tc-phytate and 30 ..mu..Ci of /sup 198/Au-colloid were injected rapidly. Ksub(L) value of sup(99m)Tc-phytate in the liver cirrhosis group was lower than the chronic hepatitis group, which was lower than the normal group. The correlation between Tsub(1/2) (L) and Tsub(1/2)(P): In the normal group, the coefficient correlation between Tsub(1/2)(L) and Tsub(1/2)(P) was fairly good both in sup(99m)Tc-phytate and in /sup 198/Au-colloid, whereas the correlation was low in the chronic hepatitis group and liver cirrhosis group. The how correlation between the Ksub(L) values of sup(99m)Tc-phytate and /sup 198/Au-colloid: The correlation of the Ksub(L) value was low in all three groups. Ksub(L) values in sup(99m)Tc-phytate were higher than they were in /sup 198/Au-colloid in all three groups. When each probe was placed on the temporal and thigh region simultaneously for obtaining the peripheral blood clearance, the Tsub(1/2)(P) value (temporal) was always smaller than the Tsub(1/2)(P) value (thigh). Grade of kidney visualization in liver scintigraphy using sup(99m)Tc-phytate: Kidney activities were seen in 72.9% of 83 patients and there was no grade difference between the normal,chronic hepatitis and liver cirrhosis group. An additional attempt to determine the nature and size of ''sup(99m)Tc-phytate in vivo colloid'', Ca ion was added to sup(99m)Tc-phytate solution prior to the injection. Lung, spleen, and liver were simultaneously visualized using this ''in vitro sup(99m)Tc-phytate minicolloid''.

  4. Significance of {sup 99m}Tc-tin Colloid Scan in Rejection of Transplanted Kidney

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Ha Young; Kim, Seung Taik; Park, Seon Yang; Kim, Sung Yang; Lee, Myung Chul; Cho, Bo Youn; Lee, Jung Sang; Koh, Chang Soon [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1982-09-15

    Renal transplant uptake of {sup 99m}Tc-tin colloid was evaluated in 26 patients. Seventy-seven examinations were performed comparing transplant with bone marrow activity, clinical and/or pathological diagnosis. There were 13 instances of acute rejection; 7 of these exhibited slight uptake of radiocolloid in the renal transplant, 1 had marked uptake, and 5 had no evidence of uptake. There were 7 instances of chronic rejection; 5 of which demonstrated marked transplant uptake of radiocolloid, 1 had slight uptake, and 1 had no evidence of uptake. There were 2 instances of acute tubular necrosis and 55 instances of normal transplant function, but none of these exhibited transplant uptake of radiocolloid. From the result, the uptake of {sup 99m}Tc-tin colloid by renal transplant appears to signal rejection as long as the vascular supply is not severely compromised. Acute rejection may be represented by slight radiocolloid uptake, and chronic rejection by marked uptake when compared to bone marrow activity.

  5. Radioimmunoimaging of subacute infective endocarditis using a technetium-99m monoclonal granulocyte-specific antibody

    Energy Technology Data Exchange (ETDEWEB)

    Munz, D L; Sandrock, D; Emrich, D [Goettingen Univ. (Germany). Abt. fuer Nuklearmedizin; Morguet, A J; Heim, A; Sold, G; Figulla, H R; Kreuzer, H [Goettingen Univ. (Germany). Abt. fuer Kardiologie und Pulmonologie

    1991-12-01

    Immunoscintigraphy with a technetium-99m murine monoclonal IgG{sub 1} antibody directed against non-specific cross-reacting antigen (NCA-95) and carcinoembryonic antigen was performed with 20 patients with suspected subacute infective endocarditis (SIE) and 6 controls with suspected inflammatory/infectious disease elsewhere in the body. Immunoscintigraphy and echocardiography localised SIE in 11 of 15 patients in whom the disease could be confirmed. In 4 patients with validated SIE, the immunoscan was abnormal, and the echocardiogram was normal. In another 4 patients, the result was exactly the opposite. These findings suggest that the combination of immunoscintigraphy and echocardiography improves diagnostic efficacy in patients with suspected SIE. (orig.).

  6. Radioimmunoimaging of subacute infective endocarditis using a technetium-99m monoclonal granulocyte-specific antibody

    International Nuclear Information System (INIS)

    Munz, D.L.; Sandrock, D.; Emrich, D.; Morguet, A.J.; Heim, A.; Sold, G.; Figulla, H.R.; Kreuzer, H.

    1991-01-01

    Immunoscintigraphy with a technetium-99m murine monoclonal IgG 1 antibody directed against non-specific cross-reacting antigen (NCA-95) and carcinoembryonic antigen was performed with 20 patients with suspected subacute infective endocarditis (SIE) and 6 controls with suspected inflammatory/infectious disease elsewhere in the body. Immunoscintigraphy and echocardiography localised SIE in 11 of 15 patients in whom the disease could be confirmed. In 4 patients with validated SIE, the immunoscan was abnormal, and the echocardiogram was normal. In another 4 patients, the result was exactly the opposite. These findings suggest that the combination of immunoscintigraphy and echocardiography improves diagnostic efficacy in patients with suspected SIE. (orig.)

  7. Technetium-99m labelled fluconazole and antimicrobial peptides for imaging of Candida albicans and Aspergillus fumigatus infections

    Energy Technology Data Exchange (ETDEWEB)

    Lupetti, Antonella [Department of Infectious Diseases, Leiden University Medical Center (LUMC), Leiden (Netherlands); Dipartimento di Patologia Sperimentale, Biotecnologie Mediche, Univ. di Pisa (Italy); Welling, Mick M. [Department of Radiology, Division of Nuclear Medicine, LUMC, Leiden (Netherlands); Mazzi, Ulderico [Dipartimento di Scienze Farmaceutiche, Universita degli Studi di Padova (Italy); Nibbering, Peter H. [Department of Infectious Diseases, Leiden University Medical Center (LUMC), Leiden (Netherlands); Pauwels, Ernest K.J. [Department of Radiology, Division of Nuclear Medicine, LUMC, Leiden (Netherlands); Department of Radiology, Leiden University Medical Center (LUMC) (Netherlands)

    2002-05-01

    The aim of this study was to investigate whether technetium-99m labelled fluconazole can distinguish fungal from bacterial infections. Fluconazole was labelled with {sup 99m}Tc and radiochemical analysis showed less than 5% impurities. The labelling solution was injected into animals with experimental infections. For comparison, we used two peptides for infection detection, i.e. UBI 29-41 and hLF 1-11, and human IgG, all labelled with {sup 99m}Tc. Mice were infected with Candida albicans or injected with heat-killed C. albicans or lipopolysaccharides to induce sterile inflammation. Also, mice were infected with Staphylococcus aureus or Klebsiella pneumoniae. Next, accumulation of {sup 99m}Tc-fluconazole and {sup 99m}Tc-labelled peptides/IgG at affected sites was determined scintigraphically. {sup 99m}Tc-fluconazole detected C. albicans infections (T/NT ratio=3.6{+-}0.47) without visualising bacterial infections (T/NT ratio=1.3{+-}0.04) or sterile inflammatory processes (heat-killed C. albicans: T/NT ratio=1.3{+-}0.2; lipopolysaccharide: T/NT ratio=1.4{+-}0.1). C. albicans infections were already seen within the first hour after injection of {sup 99m}Tc-fluconazole (T/NT ratio=3.1{+-}0.2). A good correlation (R{sup 2}=0.864; P<0.05) between T/NT ratios for this tracer and the number of viable C. albicans was found. Although {sup 99m}Tc-UBI 29-41 and {sup 99m}Tc-hLF 1-11 were able to distinguish C. albicans infections from sterile inflammatory processes in mice, these {sup 99m}Tc-labelled peptides did not distinguish these fungal infections from bacterial infections. It is concluded that {sup 99m}Tc-fluconazole distinguishes infections with C. albicans from bacterial infections and sterile inflammations. (orig.)

  8. The preparation of {sup 99m}Tc from {sup 99}Mo-{sup 99m}Tc using Poly-Zirconium Compound (PZC)

    Energy Technology Data Exchange (ETDEWEB)

    Laohawilai, S [Isotope Production Div., Office of Atomic Energy for Peace (Thailand)

    1998-10-01

    The process of for providing the {sup 99m}Tc-gel generator followed the protocol that received from Department of Radioisotopes, Tokai Research Establishment, JAERI. Sodium molybdate (molybdenum-99), pH 7 with concentration 20 mg/ml and activity nearly 1 mCi/ml was added into the adsorbent (PZC). The total activity of {sup 99}Mo was about 10 mCi and the heating time was varied from 3-18 hours at 70degC. The properties of the gel were studied for elution profile and elution efficiency. The molybdenum breakthrough in sodium pertechnetate (technetium-99m) was also performed. (author)

  9. Technetium-99 in the Irish marine environment

    Energy Technology Data Exchange (ETDEWEB)

    Smith, V.; Fegan, M.; Pollard, D.; Long, S.; Hayden, E.; Ryan, T.P

    2001-07-01

    Technetium-99 activity concentrations in seawater and biota from Irish coastal waters are presented. Time series measurements of {sup 99}Tc in seawater and Fucus vesiculosus from the western Irish Sea show that activity concentrations have increased in line with the increase in discharges of {sup 99}Tc from Sellafield. The peak in activity concentrations in both seawater and Fucus vesiculosus occurred in 1997 approximately two years after the peak in {sup 99}Tc discharges. The highest activity concentration recorded in Fucus vesiculosus showed a 29-fold increase over the mean concentration for the period 1988-1993. Technetium-99 activity concentrations were measured in fish, lobsters, prawns, mussels and oysters landed at major fishing ports on the east and northeast coasts of Ireland between 1996 and 1998. Concentration factors for {sup 99}Tc in the brown seaweed Fucus vesiculosus and certain species of fish, crustaceans and molluscs from the Irish Sea were estimated. In general, these concentration factors were higher than those in the literature which were derived from laboratory studies, but agreed well with values which were based on field studies. The mean committed effective doses to Irish typical and heavy seafood consumers due to {sup 99}Tc in the period 1996-1998 were 0.061 and 0.24 {mu}Sv, respectively.

  10. Technetium-99m radiolabeling of a recombinant dermonecrotic protein (recLiD1) from the Loxosceles venom for biodistribution study

    International Nuclear Information System (INIS)

    Valadares, D.; Felicori, L.; Olortegui, C.C.; Simal, C.; Gouvea dos Santos, R.

    2007-01-01

    In the present study the recombinant form (recLiD1) of a dermonecrotic protein present in the Brazilian brown spider Loxosceles intermedia venom was labeled with technetium-99m using stannous chloride and sodium borohydride as reducing agents. 99mTc-recLiD 1 kept its biological activity evoking dermonecrotic activity in rabbits. In vivo biodistribution in mice with the radiolabeled recLiD 1 showed high kidney uptake followed by stomach and liver uptakes. Also, we can see that 20% of toxin remaining in the skin after 120 min and once absorbed, 99mTc-recLiD 1 is rapidly cleared from the blood with long-lasting. We also observed one displacement of 99mTc-recLiD 1 by one monoclonal antibody raised against L. intermedia venom that indicates specific interaction with kidney tissue. (author)

  11. Synthesis, radiochemistry and biological evaluation of a new somatostatin analogue (SDZ 219-387) labelled with technetium-99m

    International Nuclear Information System (INIS)

    Maina, T.; Stolz, B.; Albert, R.; Bruns, C.; Koch, P.; Maecke, H.

    1994-01-01

    A new derivative of octreotide SDZ 219-387 [PnAO-(D)Phe 1 -octreotide] was synthesized, which binds specifically and with high affinity to somatostatin receptors in vitro (pK i =9.79±0.16). This new somatostatin analogue chelates technetium-99m under mild labelling conditions in good yields. The resulting [ 99m Tc]SDZ 219-387 was stable up to 6 h after labelling and could be isolated in a pure radiochemical and chemical form by high-perfomance liquid chromatographic purification. The intravenous administration of purified [ 99m Tc]SDZ 219-387 revealed that the radioligand was rapidly cleared from circulation, and tumour uptake of 0.38% ID/g was observed at 1.5 h post injection. [ 99m Tc]SDZ 219-387 specifically interacted with somatostatin binding sites on the tumour. However, the radioligand is highly lipophilic and excreted mainly through the hepatobiliary system. As a consequence, [ 99m Tc]SDZ 219-387 exhibits increased background activity and therefore is not appropriate for the in vivo visualization of somatostatin receptor-positive tumours and/or their metastases in the abdomen. (orig.)

  12. Radioimmunoscintigraphy with technetium-99m labelled monoclonal antibody, 1A3, in colorectal cancer

    International Nuclear Information System (INIS)

    Granowska, M.; Britton, K.E.; Mather, S.J.; Morris, G.; Ellison, D.; Soobramoney, S.; Talbot, I.C.; Northover, J.M.A.

    1993-01-01

    This study of radioimmunoscintigraphy (RIS) was primarily undertaken to determine how the imaging results related to surgical findings. Technetium-99m radiolabelled 1A3, a monoclonal antibody against a columnar cell surface antigen, was used. No adverse effects or thyroid uptake was observed in 127 studies. The 85 primary colorectal cancers were all image positive. In the assessment of recurrent tumour in the abdomen or pelvis, the accuracy was 33/35 (94%), including true-positive findings in some whose serum carcinoembryonic antigen was normal. There was a positive predictive value for abdominal or pelvic recurrence of 92% and a negative predictive value of 100%, at a prevalence of 66%. In those patients whose liver was able to be evaluated, the accuracy was 72/79 (91%). There was a positive predictive value for liver metastases of 88% and a negative predictive value of 93%, at a prelavence of 32%. The simple procedure for labelling antibody with 99m Tc and its ready availability allow a completed report to be given within 24 h of the request. (orig.)

  13. Clinical evaluation of salivary gland imaging with technetium-99m pertechnetate 43 cases

    International Nuclear Information System (INIS)

    Huang Daming

    1989-01-01

    Salivary gland imaging in 36 patients with benign or malignant tumor all showed the size, extent and location of tumor in parotid glands. There was no pseudonegative diagnosis in salivary gland imaging, but in sailography there were three cases with pseudo-negative diagnosis. The authors believe salivary gland imaging with Technetium-99m pertechnetate although is nonspecific for Warthin's tumor of parotid gland, and is also not able to differentiate malignant tumor from benign tumor of salivary gland, but radionuclide examination is a safe and simple diagnostic technnique and proves to have greater sensitivity in demonstrating abnormalities of salivary gland than that of routine sailography. Contrast salivarry gland imaging with sailography one can differentiate inflammation from tumor and benign from malignant tumor

  14. Study of factors that interfere in the labelling process of erythrocytes and plasma proteins with Technetium-99m

    International Nuclear Information System (INIS)

    Gutfilen, Bianca

    1989-01-01

    The labelling of red blood cells (RBC) with technetium-99m (Tc-99m) depends on several factors, as the stannous ion (Sn++) concentration, time, temperature, the presence of plasma proteins (PP) and others. However the Sn++ concentration seems to be the most important factor; probably because the uptake of this reducing agent by RBC is limited. The excess of Sn++ in extracellular medium can determine the labelling of PP. the modifications of RBC at 50 deg C described in the literature, the possibility of labelling RBC with Tc-99m at this temperature and experimental results obtained made it possible to perform spleen selective scintigraphy through a simple technique with few manipulations. The effect of gentamicin, nifedipine and verapamil in the labelling of RBC and plasma proteins with Tc-99m was studied because of similarities between Ca++ and Sn++. The results show that, under some conditions, these drugs are capable to alter this Tc-99m incorporation. The modification of the ionic distribution determined by these drugs or the blockage of Sn++ and/or Tc-99m or the fact that they bind theirselves to plasma proteins, or the possibility of the labelling of these drugs, are factors that can interfere in the labelling process of red blood cells and plasma proteins with Tc-99m. (author)

  15. An aqueous extract of Vitex agnus castus alters the labeling of blood constituents with technetium-99m

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Maria Regina de Macedo; Ribeiro, Camila Godinho; Santos-Filho, Sebastiao David; Neves, Rosane de Figueiredo; Catanho, Maria Teresa Jansem de Almeida [Universidade Federal do Rio Grande do Norte, Natal, RN (Brazil). Centro de Ciencias da Saude]. E-mail: mariaregina.mr@terra.com.br; Fonseca, Adenilson de Souza da; Bernardo-Filho, Mario [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil). Inst. de Biologia Roberto Alcantara Gomes. Dept. de Biofisica e Biometria

    2007-09-15

    The development of experimental assays to study properties of herbal medicine is worthwhile. Vitex agnus castus (VAC) is utilized in popular medicine and some actions have been attributed to its extract. Blood cells (BC) and plasma proteins are labeled with technetium-99m (Tc-99m) and have been used in nuclear medicine, as in basic research. This procedure uses a reducing agent and stannous ion is utilized. There are reports that drugs can alter this labeling process. The aim of this work was to evaluate the influence of an aqueous extract of VAC on the labeling of blood constituents with Tc-99m. Blood was incubated with VAC, stannous chloride and Tc-99m, as sodium pertechnetate, and centrifuged. Samples of BC and plasma were separated, aliquots of BC and plasma were also precipitated with trichloroacetic acid to obtain soluble and insoluble fractions and the percentage of radioactivity (%ATI) was determined. The results show a statistical (p<0.05) alteration in the %ATI on blood compartments and on the insoluble fractions of plasma and BC. Probably, this extract would have chemical compounds with oxidant properties. (author)

  16. An aqueous extract of Vitex agnus castus alters the labeling of blood constituents with technetium-99m

    International Nuclear Information System (INIS)

    Costa, Maria Regina de Macedo; Ribeiro, Camila Godinho; Santos-Filho, Sebastiao David; Neves, Rosane de Figueiredo; Catanho, Maria Teresa Jansem de Almeida; Fonseca, Adenilson de Souza da; Bernardo-Filho, Mario

    2007-01-01

    The development of experimental assays to study properties of herbal medicine is worthwhile. Vitex agnus castus (VAC) is utilized in popular medicine and some actions have been attributed to its extract. Blood cells (BC) and plasma proteins are labeled with technetium-99m (Tc-99m) and have been used in nuclear medicine, as in basic research. This procedure uses a reducing agent and stannous ion is utilized. There are reports that drugs can alter this labeling process. The aim of this work was to evaluate the influence of an aqueous extract of VAC on the labeling of blood constituents with Tc-99m. Blood was incubated with VAC, stannous chloride and Tc-99m, as sodium pertechnetate, and centrifuged. Samples of BC and plasma were separated, aliquots of BC and plasma were also precipitated with trichloroacetic acid to obtain soluble and insoluble fractions and the percentage of radioactivity (%ATI) was determined. The results show a statistical (p<0.05) alteration in the %ATI on blood compartments and on the insoluble fractions of plasma and BC. Probably, this extract would have chemical compounds with oxidant properties. (author)

  17. Detection of gastrointestinal blood loss with /sup 99m/Tc-labeled, heat-treated red blood cells

    International Nuclear Information System (INIS)

    Som, P.; Oster, Z.H.; Atkins, H.L.; Goldman, A.G.; Sacker, D.F.; Harold, W.H.; Fairchild, R.G.; Richards, P.; Brill, A.B.

    1981-01-01

    Studies in dogs showed that heat-treated /sup 99m/Tc-labeled red blood cells (HT/RBC) afford a highly sensitive means of detecting gastrointestinal bleeding as low as 0.12 ml/min, which could not be seen with unheated /sup 99m/Tc-RBC, /sup 99m/Tc-sulfur colloid, or /sup 99m/Tc-DTPA. In addition, as the right upper quadrant and epigastrium remained free of activity, only one fifth to one tenth of the dose of /sup 99m/Tc was needed. The safety of HT/RBC in humans has been documented, and the experiments in dogs suggest that it may have advantages over other agents in detecting gastrointestinal bleeding

  18. Diagnosis of acute cholecystitis using hepatobiliary scan with technetium-99m PIPIDA

    International Nuclear Information System (INIS)

    Bennett, M.T.; Sheldon, M.I.; dos Remedios, L.V.; Weber, P.M.

    1981-01-01

    Sixty patients were evaluated for acute abdominal pain using technetium-99m PIPIDA hepatobiliary imaging. The sensitivity of the test was 90.6 percent in all patients and the accuracy was 93.3 percent. In the evaluation of acutely ill patients with right upper quadrant pain, fever, nausea and vomiting, hepatobiliary imaging with PIPIDA is the preferred test for diagnosing acute cholecystitis. If the test is positive, disease of the gallbladder and probably acute cholecystitis are present. Early operation can proceed if desirable. If the test is negative and the bilirubin level is less than 5.0 mg/dl, acute cholecystitis is not present. In such cases conservative treatment is appropriate, and follow-up tests should be performed to evaluate the possibility of chronic cholecystitis. When the bilirubin level exceeds 5.0 mg/dl, the test is often indeterminate

  19. Comparison of the accumulation and efflux kinetics of technetium-99m sestamibi and technetium-99m tetrofosmin in an MRP-expressing tumour cell line

    International Nuclear Information System (INIS)

    Utsunomiya, K.; Su, Z.-F.; Ichise, M.; Ballinger, J.R.; Piquette-Miller, M.; Tang, W.; Rauth, A.M.

    2000-01-01

    The potential clinical use of technetium-99m labeled sestamibi (Tc-MIBI) and tetrofosmin (Tc-Tfos) to image tumours is currently being evaluated. In this study, the accumulation and efflux of Tc-MIBI and Tc-Tfos in the nasopharyngeal carcinoma cell line CNE-1 were examined in the presence or absence of various inhibitors of P-glycoprotein (PGP) and/or multidrug resistance associated protein (MRP) activity [GG918, PSC833, verapamil (Vrp), cyclosporin A (CsA) and buthionine sulfoximine (BSO)]. Reverse-transcriptase polymerase chain reaction analysis and immunodetection of the CNE-1 cells detected expression of MRP, MRP1 and MRP2 but not PGP. Tc-MIBI and Tc-Tfos accumulation was increased (P 2 times greater than for Tc-MIBI). However, no qualitative differences in inhibitors were seen between Tc-MIBI and Tc-Tfos. These results suggest that both Tc-MIBI and Tc-Tfos are substrates for the MRP transporter and that PSC833, Vrp, CsA and BSO but not GG918 can inhibit MRP activity. These results indicate that Tc-MIBI and Tc-Tfos may be suitable imaging agents for detecting MRP-mediated drug resistance in human cancers. (orig.)

  20. Effect of Radioactivity of Technetium-99m on the Autosterilization Process of non-sterile Tetrofosmin Kits

    Directory of Open Access Journals (Sweden)

    Widyastuti Widyastuti

    2017-03-01

    Full Text Available Technetium-99m labeled radiopharmaceutical is commonly used in nuclear medicines as a diagnostic agent, by mixing the sterile kit with Tc-99m. Manufacturing of kits requires an aseptic facility which need to be well designed and maintained according to cGMP, since mostly kits can not be terminally sterilized. Radiopharmaceuticals as pharmaceuticals containing radionuclide is assumed to have an autosterilization property, but correlation between radioactivity and capability of killing microorganisms has to be studied so far. The aim of this study is to investigate the effect of radioactivity on the autosterilization process of radiopharmaceuticals. The study was carried out by adding Tc-99m of various radioactivity into non-sterile tetrofosmin kits, then the samples were tested for sterility. Sterile tetrofosmin kit and non-sterile kit with no Tc-99m added will be used as a negative control and positive control respectively. The sterility was tested using standard direct inoculation method, by inoculating samples in culture media for both bacteria and fungi and observing qualitatively within 14 days. The results showed that the samples with radioactivity of 1, 3 and 5 mCi changed the clarity of the media to turbid, conformed with the performance of positive controls but samples with radioactivity of 10 mCi and 20 mCi did not change the clarity of the media, conformed with the performance of negative control, indicating neither growth of bacteria nor fungi. It is concluded that Tc-99m behaves as an autosterilizing agent at certain radioactivity. Therefore the preparation of Tc-99m radiopharmaceutical can be considered as terminal sterilization rather than aseptic preparation.

  1. Clinical application of calculated split renal volume using computed tomography-based renal volumetry after partial nephrectomy: Correlation with technetium-99m dimercaptosuccinic acid renal scan data.

    Science.gov (United States)

    Lee, Chan Ho; Park, Young Joo; Ku, Ja Yoon; Ha, Hong Koo

    2017-06-01

    To evaluate the clinical application of computed tomography-based measurement of renal cortical volume and split renal volume as a single tool to assess the anatomy and renal function in patients with renal tumors before and after partial nephrectomy, and to compare the findings with technetium-99m dimercaptosuccinic acid renal scan. The data of 51 patients with a unilateral renal tumor managed by partial nephrectomy were retrospectively analyzed. The renal cortical volume of tumor-bearing and contralateral kidneys was measured using ImageJ software. Split estimated glomerular filtration rate and split renal volume calculated using this renal cortical volume were compared with the split renal function measured with technetium-99m dimercaptosuccinic acid renal scan. A strong correlation between split renal function and split renal volume of the tumor-bearing kidney was observed before and after surgery (r = 0.89, P volumetry had a strong correlation with the split renal function measured using technetium-99m dimercaptosuccinic acid renal scan. Computed tomography-based split renal volume measurement before and after partial nephrectomy can be used as a single modality for anatomical and functional assessment of the tumor-bearing kidney. © 2017 The Japanese Urological Association.

  2. 99 mTc-sulphur-colloid and heat-denatured 99mTc-labelled red cell scans demonstrating a giant intrapelvic spleen in a girl after splenectomy

    International Nuclear Information System (INIS)

    Kao, P.F.; Tzen, K.Y.; Tsai, M.F.; Lin, J.N.

    2001-01-01

    A 17 x 12 x 5-cm giant intrapelvic mass in a 14-year-old girl is reported. This mass developed 6 years after a splenectomy for splenic torsion. The heat-denatured 99 m Tc-labelled red cell scan and 99 m Tc- sulphur-colloid scan confirmed the specific red cell sequestration function and reticuloendothelial activity in the giant intrapelvic spleen. The size and development of the giant intrapelvic spleen are unusual. The usefulness of functional images to diagnosis the nature of the intrapelvic mass is well demonstrated. (orig.)

  3. Technetium 99m-labeled annexin v scintigraphy of platelet activation in vegetations of experimental endocarditis

    Energy Technology Data Exchange (ETDEWEB)

    Rouzet, F.; Sarda-Mantel, L.; Le Guludec, D. [Nucl Med Serv, Grp Hosp Bichat Claude Bernard, AP-HP, Paris (France); Rouzet, F.; Sarda-Mantel, L.; LeGuludec, D. [Univ Denis Diderot Paris 7, UMR S773, Paris (France); Rouzet, F.; Sarda-Mantel, L.; Le Guludec, D. [INSERM, U773, Paris (France); Hernandez, M.D.; Louedec, L.; Michel, J.B. [Univ Paris 07, CHU Xavier Bichat, INSERM, U698, Paris (France); Hervatin, F. [CEA, DSV, DRM, SHFJ, Orsay (France); Lefort, A.; Fantin, B. [Univ Denis Diderot Paris 7, EA 3964, Paris (France); Duval, X. [Univ Denis Diderot Paris 7, INSERM, CIC 007, Paris (France); Duval, X. [Univ Denis Diderot Paris 7, AP-HP, Grp Hosp Bichat Claude Bernard, Ctr Invest Clin, Paris (France); Hernandez, M.D. [Univ Guadalajara, DeptPathol, Guadalajara 44430, Jalisco (Mexico)

    2008-07-01

    Background: The pathophysiology of infective endocarditis involves a pathogen/host tissue interaction, leading to formation of infected thrombotic vegetations. Annexin V is a ligand of phosphatidyl-serines exposed by activated platelets and apoptotic cells. Because vegetations are platelet-fibrin clots in which platelet pro-aggregant activity is enhanced by bacterial colonization, we investigated the ability of annexin V labeled with technetium {sup 99m}Tc ({sup 99m}Tc-ANX) to provide functional imaging of these vegetations in experimental models of infective endocarditis. This ability was assessed in rabbits and rats because of the different interest of these 2 species in preclinical analysis. Methods and Results: Non-bacterial thrombotic endocarditis was induced with the use of a catheter left indwelling through the aortic or tricuspid valve, and animals were injected with either a bacterial inoculum or saline. Scintigraphic investigations were performed 5 days later and showed a higher {sup 99m}Tc-ANX uptake by vegetations in infected versus non-infected animals (ratio,1.3 for in vivo acquisitions and 2 for autoradiography; P {<=} 0.0001 for all), whereas no significant uptake was present in controls. Right-sided endocarditis was associated with pulmonary uptake foci corresponding to emboli. Histological analysis of vegetations showed a specific uptake of {sup 99m}Tc-ANX at the interface between circulating blood and vegetation. In parallel, underlying myocardial tissue showed myocyte apoptosis and mucoid degeneration, without extracellular matrix degradation at this stage. Conclusions: {sup 99m}Tc-ANX is suitable for functional imaging of platelet-fibrin vegetations in endocarditis, as well as embolic events. {sup 99m}Tc-ANX uptake reflects mainly platelet activation in the luminal layer of vegetations. This uptake is enhanced by bacterial colonization. (authors)

  4. Resting technetium-99m methoxyisobutylisonitrile cardiac imaging in chronic coronary artery disease: comparison with rest-redistribution thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Cuocolo, A.; Maurea, S.; Pace, L.; Nicolai, E.; Nappi, A.; Imbriaco, M.; Trimarco, B.; Salvatore, M.

    1993-01-01

    We studied 19 patients with angiographically proven coronary artery disease and left ventricular dysfunction (ejection fraction 33%±8%) by resting technetium-99m methoxyisobutylisonitrile ( 99m Tc-MIBI) and rest-redistribution thallium-201 cardiac imaging. Thallium and 99m Tc-MIBI studies were visually analysed. Of 285 segments, 203 (71%) had normal thallium uptake, 48 (17%) showed reversible thallium defects and 34 (12%) showed irreversible thallium defects. Of these 34 irreversible thallium defects, 19 (56%) were moderate and 15 (44%) were severe. Of the corresponding 285 segments, 200 (70%) had normal 99m Tc-MIBI uptake, while 37 (13%) showed moderate and 48 (17%) showed severe reduction of MIBI uptake. Myocardial segmental agreement for regional uptake score between initial thallium and resting 99m Tc-MIBI images was 90% (κ=0.78). Segmental agreement between delayed thallium and resting 99m Tc-MIBI images was 77% (κ=0.44). In particular, in 26 (9%) segments 99m Tc-MIBI uptake was severely reduced while delayed thallium uptake was normal or only moderately reduced. These data suggest that although rest-redistribution thallium and resting 99m Tc-MIBI cardiac imaging provide concordant results in the majority of myocardial segments, some segments with severely reduced resting 99m Tc-MIBI uptake may contain viable but hypoperfused myocardium. Thus, conclusions on myocardial viability based on 99m Tc-MIBI uptake should be made with caution in chronic coronary artery disease. (orig.)

  5. Splenic uptake of both technetium-99m diphosphonate and technetium-99m sulfur colloid in sickle cell beta degrees thalassemia

    International Nuclear Information System (INIS)

    Heck, L.L.; Brittin, G.M.

    1989-01-01

    A 19-year-old black woman with sickle cell beta degrees thalassemia had experienced more than 100 hospital admissions for sickle cell crisis and aseptic necrosis of both femoral heads. Her spleen was enlarged threefold and accumulated both radiocolloid and bone-seeking agent on two occasions, demonstrating an exception to the rule in sickle cell anemia that spleens that take up bone-seeking agents demonstrate functional asplenia. In the context of fever, left upper quadrant pain, and splenomegaly, the pattern of calcification in the patient's spleen as revealed in ultrasound and CT studies suggested possible abscess and led to unnecessary splenectomy. The nuclear medicine studies did not support this diagnosis. Nuclear medicine physicians should not be misled by splenic findings of sickle cell thalassemia (and possibly of other heterozygous sickle cell disorders) that differ from those of the more familiar homozygous sickle cell anemia

  6. Technetium-99 in ''instant'' sup(99m)Tc-pertechnetate

    International Nuclear Information System (INIS)

    Mattsson, S.

    1978-01-01

    The 99 Tc-content in sup(99m)Tc-pertechnetate separated from 99 Mo by distillation or extraction has been studied with a plastic scintillation detector. The identification of the measured activity was achieved by beta-spectrometry, chemical separation and half-life studies. The frequency distribution of the sup(99)Tc/sup(99m)Tc-ratios in the different samples was observed to be log-normal. The most likely activity ratio was 0.4x10 -6 , the maximum value being 5x10 -6 . The specific activity of ''instant'' pertechnetate is approximately a factor of 60 lower than that normally recorded in pertechnetate derived from daily eluted column generators. The low specific activity of ''instant'' pertechnetate is primarily explained by the long time between separation and usage and secondly by the low yield of Tc in the distillation and extraction processes. In several of the ''instant'' pertechnetate solutions the carrier concentration exceeded the reductive capacity of the stannous ions in ''kits'' with small amounts of Sn(II) in usable form. (T.G.)

  7. Technetium-99m sestamibi imaging in paediatric neuroblastoma and ganglioneuroma and its relation to P-glycoprotein

    International Nuclear Information System (INIS)

    Moerloose, B. de; Dhooge, C.; Benoit, Y.; Laureys, G.; Wiele, C. van de; Dierckx, R.A.; Philippe, J.; Speleman, F.

    1999-01-01

    Imaging with technetium-99m sestamibi offers a non-invasive approach to detect the presence of functional P-glycoprotein (Pgp), one of the major causes of multidrug resistance, in human malignancies. A clinical role for Pgp has been suggested in the subpopulation of primary neuroblastoma without amplification of the proto-oncogene MYCN. We wanted to evaluate the usefulness of 99m Tc-sestamibi scintigraphy in the screening of neural crest tumours for the presence of Pgp. In ten children suffering from MYCN-negative neuroblastoma, ganglioneuroblastoma or ganglioneuroma, 99m Tc-sestamibi imaging was performed at initial diagnosis. All patients underwent planar imaging 20-30 min and 3.5-4 h after intravenous injection of 740 MBq/1.73 m 2 99m Tc-sestamibi. Tumour to normal tissue ratios, as well as washout rates, were determined and compared with in vitro flow cytometric analysis of Pgp expression and function. Pgp expression was analysed flow cytometrically with the monoclonal antibodies 4E3 and MRK16, and Pgp function was evaluated by means of rhodamine 123 uptake and efflux either in the absence or in the presence of the Pgp inhibitor verapamil. In nine of ten patients, we found that the intratumoral 99m Tc-sestamibi activity was comparable to the background activity, which might be suggestive of Pgp presence. This was confirmed flow cytometrically in all but one patient. 99m Tc-sestamibi enhancement was seen in the primary tumour and the bone marrow metastases of one of the ten patients, and this result was concordant with a negative Pgp status. The findings presented suggest that 99m Tc-sestamibi imaging results might correlate with the presence of functional Pgp in neural crest tumours without MYCN amplification. (orig.)

  8. Technetium-99m sestamibi imaging in paediatric neuroblastoma and ganglioneuroma and its relation to P-glycoprotein

    Energy Technology Data Exchange (ETDEWEB)

    Moerloose, B. de; Dhooge, C.; Benoit, Y.; Laureys, G. [Department of Pediatrics, University Hospital Gent (Belgium); Wiele, C. van de; Dierckx, R.A. [Department of Nuclear Medicine, University Hospital Gent (Belgium); Philippe, J. [Department of Clinical Chemistry, Microbiology and Immunology, University Hospital Gent (Belgium); Speleman, F. [Department of Medical Genetics, University Hospital Gent (Belgium)

    1999-04-29

    Imaging with technetium-99m sestamibi offers a non-invasive approach to detect the presence of functional P-glycoprotein (Pgp), one of the major causes of multidrug resistance, in human malignancies. A clinical role for Pgp has been suggested in the subpopulation of primary neuroblastoma without amplification of the proto-oncogene MYCN. We wanted to evaluate the usefulness of {sup 99m}Tc-sestamibi scintigraphy in the screening of neural crest tumours for the presence of Pgp. In ten children suffering from MYCN-negative neuroblastoma, ganglioneuroblastoma or ganglioneuroma, {sup 99m}Tc-sestamibi imaging was performed at initial diagnosis. All patients underwent planar imaging 20-30 min and 3.5-4 h after intravenous injection of 740 MBq/1.73 m{sup 2} {sup 99m}Tc-sestamibi. Tumour to normal tissue ratios, as well as washout rates, were determined and compared with in vitro flow cytometric analysis of Pgp expression and function. Pgp expression was analysed flow cytometrically with the monoclonal antibodies 4E3 and MRK16, and Pgp function was evaluated by means of rhodamine 123 uptake and efflux either in the absence or in the presence of the Pgp inhibitor verapamil. In nine of ten patients, we found that the intratumoral {sup 99m}Tc-sestamibi activity was comparable to the background activity, which might be suggestive of Pgp presence. This was confirmed flow cytometrically in all but one patient. {sup 99m}Tc-sestamibi enhancement was seen in the primary tumour and the bone marrow metastases of one of the ten patients, and this result was concordant with a negative Pgp status. The findings presented suggest that {sup 99m}Tc-sestamibi imaging results might correlate with the presence of functional Pgp in neural crest tumours without MYCN amplification. (orig.) With 4 figs., 2 tabs., 44 refs.

  9. Quantification of myocardial infarct size by technetium-99m pyrophosphate single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Hiromichi; Fukuyama, Takaya; Aoki, Makoto; Inou, Tetsuji; Ashihara, Toshiaki; Nabeyama, Shyohzou; Yamamoto, Yuhsuke

    1989-04-01

    Myocardial infarct size in 41 patients with the first attack of acute transmural myocardial infarction (MI) was assessed by technetium-99m pyrophosphate single photon emission computed tomography (/sup 99m/TcPYP-SPECT). A ratio of the number of voxels of /sup 99m/TcPYP uptake into the infarct area to that into the thorax was calculated as a parameter of MI size. The ratio was positively correlated with both peak CPK activity (r=0.53, p<0.005, n=24) and extent score in /sup 201/Tl-SPECT (r=0.70, p<0.005, n=14) significantly in patients with anterior MI but not in patients with inferior MI. There was also significant negative correlation between the ratio and the left ventricular ejection fraction (LVEF) measured by RI angiography in both acute (r=-0.67, p<0.005, n=18) and chronic (r=-0.75, p<0.005, n=25) phases in patients with anterior MI. Recovery in LVEF at chronic phase was noted in patients with small anterior MI but not with large anterior MI. Eight of 14 patients with inferior MI had right ventricular MI, that might have affected evaluation of MI size and resulted in no correlation between variables. It was suggested that /sup 99m/TcPYP-SPECT was a useful method to evaluate MI size and to predict prognosis of cardiac function in patients with anterior MI but not in patients with inferior MI. (author).

  10. Thrombolytic therapy for myocardial infarction: Assessment of efficacy by myocardial perfusion imaging with technetium-99m sestamibi

    International Nuclear Information System (INIS)

    Wackers, F.J.

    1990-01-01

    Technetium-99m (Tc-99m) sestamibi has been used to evaluate the efficacy of thrombolytic therapy. Improved image quality due to the higher photon energy of Tc-99m and the increased allowable doses of this radiopharmaceutical along with its lack of redistribution makes Tc-99m sestamibi an acceptable imaging agent for such studies. This imaging agent was used for serial quantitative planar and tomographic imaging to assess the initial risk area of infarction, its change over time and the relation to infarct-related artery patency in patients with a first acute myocardial infarction. Twenty-three of 30 patients were treated with recombinant tissue-type plasminogen activator (rt-PA) within 4 hours after onset of acute chest pain. Seven patients were treated in the conventional manner and did not receive thrombolytic therapy. The initial area at risk varied greatly both in patients treated with rt-PA and in those who received conventional therapy. Patients with successful thrombolysis and patient infarct arteries had a significantly greater reduction of Tc-99m sestamibi defect size than patients who had persistent coronary occlusion. Serial imaging with Tc-99m sestamibi could find important application in future clinical research evaluating the efficacy of new thrombolytic agents. Direct measurements of the amount of hypoperfused myocardium before and after thrombolysis could provide rapid and unequivocal results using fewer patients and avoiding the use of mortality as an end point. This approach has not yet been widely tested in the clinical arena

  11. Determination of technetium-99 in environmental samples: A review

    DEFF Research Database (Denmark)

    Shi, Keliang; Hou, Xiaolin; Roos, Per

    2012-01-01

    Due to the lack of a stable technetium isotope, and the high mobility and long half-life, 99Tc is considered to be one of the most important radionuclides in safety assessment of environmental radioactivity as well as nuclear waste management. 99Tc is also an important tracer for oceanographic...... research due to the high technetium solubility in seawater as TcO4−. A number of analytical methods, using chemical separation combined with radiometric and mass spectrometric measurement techniques, have been developed over the past decades for determination of 99Tc in different environmental samples....... This article summarizes and compares recently reported chemical separation procedures and measurement methods for determination of 99Tc. Due to the extremely low concentration of 99Tc in environmental samples, the sample preparation, pre-concentration, chemical separation and purification for removal...

  12. Emission computed tomography with technetium-99m pyrophosphate for delineating location and size of acute myocardial infarction in man

    Energy Technology Data Exchange (ETDEWEB)

    Tamaki, S; Kadota, K; Kambara, H; Suzuki, Y; Nohara, R; Murakami, T; Kawai, C; Tamaki, N; Torizuka, K [Kyoto Univ. (Japan). Faculty of Medicine

    1984-07-01

    Emission computed tomography with technetium-99m pyrophosphate was used to delineate the location and estimate the size of myocardial infarcts in 20 patients with documented acute myocardial infarction. Tomography was performed after planar imaging within 2-5 days after the onset of infarction. Infarct volume was measured from the tomographic images by computerised planimetry and compared with the cumulative release of creatine kinase MB isoenzyme. The planar images showed discrete myocardial uptake in 13 of the 20 patients and diffuse uptake throughout the cardiac region in the remaining seven. In contrast, the tomographic images clearly delineated myocardial uptake by avoiding confusion of myocardial activity with that of surrounding structures, particularly bones, in all patients. For the 10 patients whose infarct size was assessed by analysis of the creatine kinase MB curve there was a close correlation between infarct volume estimated by tomography and by cumulative creatine kinase MB release. Thus emission computed tomography can provide a three dimensional map of technetium-99m pyrophosphate distribution within the heart and is thus able accurately to localise and estimate the size of myocardial infarcts in man.

  13. Emission computed tomography with technetium-99m pyrophosphate for delineating location and size of acute myocardial infarction in man

    International Nuclear Information System (INIS)

    Tamaki, S.; Kadota, K.; Kambara, H.; Suzuki, Y.; Nohara, R.; Murakami, T.; Kawai, C.; Tamaki, N.; Torizuka, K.

    1984-01-01

    Emission computed tomography with technetium-99m pyrophosphate was used to delineate the location and estimate the size of myocardial infarcts in 20 patients with documented acute myocardial infarction. Tomography was performed after planar imaging within 2-5 days after the onset of infarction. Infarct volume was measured from the tomographic images by computerised planimetry and compared with the cumulative release of creatine kinase MB isoenzyme. The planar images showed discrete myocardial uptake in 13 of the 20 patients and diffuse uptake throughout the cardiac region in the remaining seven. In contrast, the tomographic images clearly delineated myocardial uptake by avoiding confusion of myocardial activity with that of surrounding structures, particularly bones, in all patients. For the 10 patients whose infarct size was assessed by analysis of the creatine kinase MB curve there was a close correlation between infarct volume estimated by tomography and by cumulative creatine kinase MB release. Thus emission computed tomography can provide a three dimensional map of technetium-99m pyrophosphate distribution within the heart and is thus able accurately to localise and estimate the size of myocardial infarcts in man. (author)

  14. Technetium-99m direct radiolabeling of monoclonal antibody ior egf/r3

    Energy Technology Data Exchange (ETDEWEB)

    Morales, Alejo A. Morales; Crespo, Francisco Zayas; Gandolff, Gilda Nunez; Escobar, Normando Iznaga; Perez, Niuvis Perez; Hernandez, Juan C. Izquierdo

    1998-01-01

    Monoclonal antibodies (MAbs) are being widely used for imaging studies, coupled mainly with {sup 99m}Tc. The antibody ior egf/r3 is a MAb against human epidermal growth factor receptor (hEGF-r), and we have developed a method for optimum labeling of this MAb with {sup 99m}Tc. The reduction was performed with 2-mercaptoethanol (2-ME) at a molar ratio of 2000:1 (2-ME:MAb) and methylene diphosphonate as transchelant. The integrity of reduced MAb was checked by mean of native polyacrylamide gel electrophoresis (PAGE) and gel filtration chromatography on Superose 12 (purity >99%). Radio colloids remained lower than 2%, and the labeling efficiency was 98.5%. The number of sulfhydryl groups generated was quantified using Ellman's reagent and was found to be 6.65 {+-} 0.69 per antibody molecule. In vitro stability studies in several challenging conditions (DTPA, human serum albumin and human serum) were performed, and no significant loss in binding percentage was seen. Radio receptor assay was used to test immunoreactivity of the reduced MAb. Both labeled and unlabeled MAbs were able to compete for binding to the hEGF-r with radioiodinated EGF. Biodistribution studies in BALB/c mice are reported.

  15. Technetium-99m direct radiolabeling of monoclonal antibody ior egf/r3

    International Nuclear Information System (INIS)

    Morales, Alejo A. Morales; Crespo, Francisco Zayas; Gandolff, Gilda Nunez; Escobar, Normando Iznaga; Perez, Niuvis Perez; Hernandez, Juan C. Izquierdo

    1998-01-01

    Monoclonal antibodies (MAbs) are being widely used for imaging studies, coupled mainly with 99m Tc. The antibody ior egf/r3 is a MAb against human epidermal growth factor receptor (hEGF-r), and we have developed a method for optimum labeling of this MAb with 99m Tc. The reduction was performed with 2-mercaptoethanol (2-ME) at a molar ratio of 2000:1 (2-ME:MAb) and methylene diphosphonate as transchelant. The integrity of reduced MAb was checked by mean of native polyacrylamide gel electrophoresis (PAGE) and gel filtration chromatography on Superose 12 (purity >99%). Radio colloids remained lower than 2%, and the labeling efficiency was 98.5%. The number of sulfhydryl groups generated was quantified using Ellman's reagent and was found to be 6.65 ± 0.69 per antibody molecule. In vitro stability studies in several challenging conditions (DTPA, human serum albumin and human serum) were performed, and no significant loss in binding percentage was seen. Radio receptor assay was used to test immunoreactivity of the reduced MAb. Both labeled and unlabeled MAbs were able to compete for binding to the hEGF-r with radioiodinated EGF. Biodistribution studies in BALB/c mice are reported

  16. Dissemination of bacteria labeled with technetium-99m after laparotomy and abdominal insufflation with different CO2 pressures on rats

    International Nuclear Information System (INIS)

    Pitombo, Marcos Bettini; Faria, Clarice Abreu dos Santos Albuquerque de; Steinbruck, Klaus; Bernardo, Luciana Camargo; Bernardo Filho, Mario

    2008-01-01

    Purpose: To asses the dissemination of bacteria labeled with technetium-99m (99mTc) from peritoneal cavity after different surgical procedures. Methods: Bacteria of the Escherichia coli species labeled with 99mTc were used in a concentration of 108 units of colony-makers for ml (UFC/ml) and 1 ml was inoculated through intra-peritoneal via. Forty-eight rats were divided into four groups: control, laparotomy, pneumoperitoneum with 10 mmHg and pneumoperitoneum with 20 mmHg of CO2. Procedures were performed 20 min after injection of the inoculum and lasted 30 min. Animals were sacrificed after six hours (Group 1) and 24 hours (Group 2). Samples of blood, liver and spleen were collected for radioactivity counting. Results: After six hours, indirect detection of the bacteria in different organs was uniform in all groups. After 24 hours, a larger detection of technetium was observed in the livers of animals of the group insufflated with 20 mmHg of CO2, when compared with those of control group (p<0.01). The other groups did not present statistically significant variations. Conclusions: The use of a higher intra-abdominal pressure was associated with a higher bacterial dissemination to the liver. The application of lower intra-abdominal pressures may be associated with a lower dissemination of the infectious status during laparoscopic approach of peritonitis status. (author)

  17. Determination of technetium-99 in environmental samples: A review

    International Nuclear Information System (INIS)

    Shi Keliang; Hou Xiaolin; Roos, Per; Wu Wangsuo

    2012-01-01

    Highlights: ► The source term, physicochemical properties, environmental distribution and behaviour of 99 Tc are presented. ► Various sample pre-treatment and pre-concentration techniques of technetium are discussed. ► Chemical separation and purification techniques for 99 Tc in environmental samples are reviewed. ► Measurement techniques for 99 Tc in environmental level and automated analytical methods are reviewed. ► The reported analytical methods of 99 Tc are critically compared to provide overall information. - Abstract: Due to the lack of a stable technetium isotope, and the high mobility and long half-life, 99 Tc is considered to be one of the most important radionuclides in safety assessment of environmental radioactivity as well as nuclear waste management. 99 Tc is also an important tracer for oceanographic research due to the high technetium solubility in seawater as TcO 4 − . A number of analytical methods, using chemical separation combined with radiometric and mass spectrometric measurement techniques, have been developed over the past decades for determination of 99 Tc in different environmental samples. This article summarizes and compares recently reported chemical separation procedures and measurement methods for determination of 99 Tc. Due to the extremely low concentration of 99 Tc in environmental samples, the sample preparation, pre-concentration, chemical separation and purification for removal of the interferences for detection of 99 Tc are the most important issues governing the accurate determination of 99 Tc. These aspects are discussed in detail in this article. Meanwhile, the different measurement techniques for 99 Tc are also compared with respect to advantages and drawbacks. Novel automated analytical methods for rapid determination of 99 Tc using solid extraction or ion exchange chromatography for separation of 99 Tc, employing flow injection or sequential injection approaches are also discussed.

  18. Technetium 99m SESTAMIBI myocardial perfusion imaging: Comparison between treadmill, dipyridamole and trans-oesophageal atrial pacing 'stress' tests in normal subjects

    International Nuclear Information System (INIS)

    Primeau, M.; Taillefer, R.; Lambert, R.; Essiambre, R.; Honos, G.

    1991-01-01

    The purpose of this study was to determine the blood clearance, myocardial uptake and heart/lung and heart/liver ratios of technetium 99m methoxyisobutylisonitrile ( 99m Tc-SESTAMIBI) following 3 different types of cardiac stimulation in normal subjects: Treadmill stress (STRESS), intravenous administration of dipyridamole (DIP) and trans-oesophageal atrial pacing (TAP). Ten normal volunteers were submitted to 3 injections of 99m Tc-SESTAMIBI (10 mCi/70 kg, separated by an interval of 7 days) following STRESS (standard Bruce protocol), DIP (0.142 mg/kg.min during 4 min) and TAP procedures. Blood samples were collected from 1 to 60 min after each 99m Tc-SESTAMIBI injection. Planar imaging was performed at 5, 30 and 60 min. Blood retention (percentage of injected dose at 1 min) was 56%±4%, 24%±4% and 38%±6% for STRESS, DIP and TAP, respectively (P 99m Tc-SESTAMIBI. (orig.)

  19. Development of a lymphscintigraphy agent: Tc-99m-Sn-PO4

    International Nuclear Information System (INIS)

    Gilliland, D.L.; Basmadjian, G.P.; Kirschner, A.S.; Leonard, J.C.; Ice, R.D.

    1979-01-01

    Stannous chloride dissolved in a solution of Na 2 HO 4 pH 9.0 gives a stable solution of Sn(II) ions. When pertechnetate-99m is added to such a solution, a stable, soluble complex of technetium-99m-Sn-PO 4 results. This is a mixed metal complex in which the Tc is present in the (III) + oxidation state and the Sn is an integral part of the complex. This complex, when injected I.V., localizes in the RES due to the formation of an in-vivo colloid with Ca(II) ions in the blood. When injected subcutaneously (SC), the complex travels through the lymphatic channels and localizes in the lymph nodes. In rabbits, axillary and popliteal nodes were visualized after injecting SC into the dorsum of the hind and fore paws. In addition, uptake by the liver, kidneys and bone marrow was noted. After intratesticular injection in dogs, the para-aortic lymph nodes were imaged at 3 to 30 minutes

  20. Preparation and assessment of [99mTc]technetium aquacarbonyl complexes with 1,2-diaminoethane-N-substituted ligands for tumor detection

    International Nuclear Information System (INIS)

    Radin, Adriano

    2010-01-01

    Over least 15 years the complex [[ 99m Tc](H 2 0) 3 (CO) 3 ] + has been used as an intermediary to obtain technetium radiopharmaceuticals for applications in cardiology, neurology and oncology. Two important characteristics of this molecule are: the facility for obtaining that compound from aqueous solutions and the easiness of substituting H 2 O molecules by atoms of other ligand molecules. In this project we prepared new complexes [[ 99m Tc](CMN S001-3 )(H 2 O)(CO) 3 ] + , where (CMNS001) = N-[(4-methoxy) benzyl]-1,2-diaminoethane, (CMNS003) = N,N'-bis-[(4-methoxy)benzyl]-1,2-diaminoethane, and assessed the uptake of these complexes in murine melanoma cancer cell B16F10 and breast cells MCF-7 and MDA-MD-231, and compared with [[ 99m ](MIBI) 6 ] + uptake. In vitro uptake for both new technetium complex reached values close to 5%, for all cell lines, whereas the [[ 99m Tc](MIBI) 6 ] + uptake was close to 1 %. The assessment of subcellular distribution showed high accumulation of the new complex in the membrane fraction, for MDAMB-231, while for B16F10 accumulation occurred both in membrane and cytoplasm; the concentration of [[ 99m Tc](MIBI) 6 ] + was mainly in the cytoplasm portion. Biodistribution study in mice allowed to observe the capture of up to 1.6% of the administered dose per gram of tumor tissue for the complex [[ 99m Tc](CMNS001)(H 2 O)(CO) 3 ] + , whereas other organs such as heart, lung and muscle, showed uptake of about 5.6%, 6.4% and 2%, respectively. The complexes in this work showed a high rate of uptake in vitro, but was not reproduced in vivo model, which can be related to low concentration of the complexes inside the cells and reduced vascularity of tumor tissue, with lower intake of complex through the blood system. (author)

  1. Coordination chemistry of technetium as related to nuclear medicine

    International Nuclear Information System (INIS)

    Srivastava, S.C.; Richards, P.

    1982-01-01

    Significant advances have been made in the area of technetium coordination chemistry during the last five years. The main driving force behind this recent surge of interest in the field has been due to the practical application of technetium-99m in the rapidly growing speciality of nuclear medicine. Technetium-99 is one of the products of nuclear fission reactions, but it was the development of the molybdenum-99-technetium-99m generator about two decades ago that provided the basis for the development of radiopharmaceuticals routinely used in modern diagnostic applications. The chemistry of this element has proven to be quite rich owing to its multiple oxidation states and variable geometry. This can be attributed to its position in the middle of the periodic table. Diagnostic radiopharmaceuticals comprise predominantly III, IV and V oxidation states of Tc and involve a variety of coordination complexes. Even though the chemistry of Tc has been slow to evolve, recent synthetic advances have provided a more scientific basis for the study of a number of compounds with diverse coordination geometries and structures. Ligands with oxygen, nitrogen and sulfur donor atoms have been utilized to elucidate various aspects of the coordination chemistry of Tc. Single crystal X-ray structural analysis has been extensively used to characterize Tc complexes and thus construct a firm foundation for the study of synthetic and mechanistic aspects of the chemistry of this element. (author)

  2. Minimizing Molybdenum 99 contamination in Technetium 99m Pertechnetate from the elution of 99Mo/ 99m Tc Generator

    International Nuclear Information System (INIS)

    Zakaria Ibrahim; Zulkifli Hashim; Bohari Yaacob

    2011-01-01

    Radioisotope Tc-99m is widely used for variety of nuclear medicine diagnostic procedures. For many commercial applications, it is prepared in a portable type generator. Nuclear Malaysia has been producing a dry type alumina chromatographic column generator utilizing fission Mo-99. This injectable Tc-99m must meet the British Pharmacopeia [1] product specification prior to be apply on patient. This paper provides a method to minimize the up to acceptable level Mo-99 in the final product. Purposely made pertechnetate contaminated with Mo-99 and re-eluate by using old generator. Excellent removal of Mo-99 impurity was achieved and more than 80 % of Tc-99m total activity was recovered. (author)

  3. Quantitative analysis of acute myocardial infarction using single photon emission computed tomography using technetium-99m pyrophosphate

    International Nuclear Information System (INIS)

    Fujiwara, Yasushi; Kokubu, Tatsuo; Murase, Kenya; Hamamoto, Ken; Itoh, Taketoshi; Doiuchi, Junji; Ochi, Takaaki.

    1986-01-01

    The usefulness of single photon emission computed tomography (SPECT) using technetium-99m pyrophosphate ( 99m Tc-PPi) was evaluated in 15 patients with acute myocardial infarction. SPECT was performed with a rotating gamma camera after conventional planar images were made. Infarct size was measured from transaxial images of myocardial pyrophosphate uptakes. In each slice, the boundary was defined by subtracting 70 percent of the maximal counts and the number of voxels automatically counted. This subtraction rate was determined by phantom study and by compraing SPECT using 99m Tc-PPi with thallium-201-gated myocardial scintigraphy ( 201 Tl gated SPECT). The planar images showed diffuse uptakes in two of the 15 patients, and in these cases it was difficult to detect the infarct site. In contrast, SPECT images clearly imaged the infarct site consistent with the electrocardiographic findings, and they were definitely separated from the uptakes in the bones in all cases. Infarct size, ranging from 3.4 ml to 78.3 ml, correlated well with cumulative creatine kinase release (r = 0.84, p 99m Tc-PPi is a useful means of investigating the spatial distribution of pyrophosphate uptake and of evaluating the size of myocardial infarction. (author)

  4. Blood cell labeling with technetium-99m, (2)

    International Nuclear Information System (INIS)

    Uchida, Tatsumi; Yoshida, Hiroshi; Matsuda, Shin; Kimura, Hideo; Miura, Nobuo

    1978-01-01

    Using a labeling method with sup(99m)Tc-pertechnetate to red blood cells (RBC), circulating blood volume was measured in comparison with that from 51 Cr-labeled RBC method. The technique is easier than already published methods, because CIS kit for sup(99m)Tc-RBC labeling (TCK-11) became to be available recently. Two mls of ACD-anticoagulated blood were withdrawn and 0.5 ml of reducing reagent prepared just before use was added to blood, waiting 5 minutes and discarding the serum after centrifugation, then adding 100 μCi of sup(99m)Tc. After washing the labeled cells by isotonic saline, cells were re-suspended in 10 ml of saline and injected to the subject. Blood specimen was obtained 10, 30, 60 and 120 minutes after infusion and blood volume was calculated by the usual way. Circulating blood volume by sup(99m)Tc was well correlated with that by 51 Cr (=0.98, p 0.01), however, the value calculated from sup(99m)Tc were 4.8 percent higher than those by 51 Cr, which suggested the elution of sup(99m)Tc from labeled RBC. sup(99m)Tc method has the advantages that higher radioactivity can be obtained in small amount of blood, which is useful in the determination of blood volume in children or in small animals in the laboratory. The measurement of blood volume of the mouse was done by using sup(99m)Tc method. The results were 1.70 +- 0.06 ml (6.35 +- 0.18%/gm), which coincided with the values reported previously. Because of it's short half life and low radiation dosage to the patients, sup(99m)Tc method will be recommended in the field of pediatrics or in patients with polycythemia or congestive heart failure, who are requested the repeated measurement of blood volume. (auth.)

  5. Hepatoscintigraphy with /sup 99m/Tc-colloid in children with liver cirrhosis

    Energy Technology Data Exchange (ETDEWEB)

    Mironov, S P

    1987-03-01

    Children aged 2 to 14 with the initial, formed and terminal stages of liver cirrhosis were examined by a method of radionuclide scintigraphy with /sup 99m/Tc-colloid. A set of indices characterizing function of the reticuloendothelial system (RES), the effective hepatic blood flow, metric parameters of the liver and spleen were obtained from an analysis of the curves of the heart, liver and spleen area, and digital imaging of the liver with the marked costal arch. It was shown that at the initial stage of disease indices of the time course of the radioactive colloid were of compensated nature. Spleen function was elevated, liver and spleen sizes were increased. The formed stage was characterized by the signs of subcompensation of liver function: changes of indices of RP retention in the blood, a decrease in the indices of the total and hepatic radioactive colloid. The terminal stage was characterized by marked disorder of liver RES function which was not compensated for by a high splenic uptake, image deformation and focal RP distribution. Irrespective of a stage of disease the syndrome of portal hypertension was shown to manifest itself in splenomegaly and an increase in the radioactive colloid uptake by the liver over 15%. The accuracy of the set of signs was 90%.

  6. Stabilization of marked hexametazima with technetium 99-metastables (99mTc) with chloride of cobalt hexahidratado, for the labelling of leukocytes

    International Nuclear Information System (INIS)

    Oliva Palencia, Rosa Maria

    1996-01-01

    Presently study you work with hexametilpropilen amino oxima (HM-PAO), radiopharmaceuticals of labelling leucocytes marking it with technetium 99 recently acquired of the second elution of a generator of molybdenum technetium adding chloride of cobalt hexahidratado in different concentrations, as stabilizing agent in order to settling down if it prolongs the useful life of this expensive radiopharmaceuticals for but of minutes. For it one carries out the determination from the purity radiochemical to the 5,60,120 and 180 minutes after the labelled and the labelling of leukocytes is made with quality control of the cells after the labelling compared against a control

  7. Measurement of technetium-99 in soil samples collected in Marshall Islands

    Energy Technology Data Exchange (ETDEWEB)

    Tagami, K.; Uchida, S. [National Inst. of Radiological Sciences, Environmental and Toxicological Sciences Research Group, Chiba (Japan)

    2000-07-01

    Extraction techniques for recovery of technetium-99 ({sup 99}Tc) for ICP-MS measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (M1) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for {sup 99}Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the {sup 99}Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The {sup 99}Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq/g-dw. The limit of detection for {sup 99}Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq/g-dw under standard operating conditions. (author)

  8. Measurement of technetium-99 in soil samples collected in Marshall Islands

    International Nuclear Information System (INIS)

    Tagami, K.; Uchida, S.

    2000-01-01

    Extraction techniques for recovery of technetium-99 ( 99 Tc) for ICP-MS measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (M1) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for 99 Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the 99 Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The 99 Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq/g-dw. The limit of detection for 99 Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq/g-dw under standard operating conditions. (author)

  9. Thermal neutron cross section measurements for technetium-99

    International Nuclear Information System (INIS)

    Yates, M.A.; Schroeder, N.C.; Fowler, M.M.

    1993-01-01

    Technetium, because of its long half-like (213,000 years) and ability to migrate in the environment, is a primary contributor to the long-term radioactivity related risk associated with geologic nuclear waste disposal. One proposal for converting technetium to an environmentally benign element investigating transmutation with an accelerator-based system, (i.e., Accelerator Transmutation of Waste, ATW). Planning for efficient processing of technetium through the transmuter will require knowledge of the thermal neutron cross section for the 99 Tc (n,γ) 100 Tc reaction. The authors have recently remeasured this cross section. Weighed aliquots (19-205 μg) of a NIST traceable 99 Tc standard were irradiated for 30-150 sec using the pneumatic open-quotes rabbitclose quotes system of LANL's Omega West Reactor. The two gamma rays from the 15.7-sec half-life product were measured immediately after irradiation on a high-resolution Ge detector. Thermal fluxes were measured using gold foils and Cd wrapped gold foils. The observation cross section is 19 ± 1 b. This agrees well with the 1977 value but has half the uncertainty

  10. Application of photoactivation in the preparation of radiopharmaceuticals. Pt. 3. Human serum albumin labelled with technetium (99mTc)

    International Nuclear Information System (INIS)

    Komarek, P.; Kleisner, I.; Konopkova, M.; Komarkova, I.

    1997-01-01

    Human serum albumin was photoactivated with UV light at 254 nm and labelled with technetium ( 99m Tc) by reducing pertechnetate ( 99m Tc) with stannous chloride. Radiochemical purity was determined by using paper chromatography, columns and electrophoresis. The biodistribution of labelled albumin in rats was assessed by activity counting in isolated organs 15 and 60 minutes after administration. Photoactivation increases the number of free SH groups, which affect favourably the labelling efficiency. Irradiated albumin exhibits a higher labelling efficiency (99%) than non-irradiated albumin (96%). The structural changes depend on the UV radiation dose, concentration of irradiated substances, and metal ion content (Sn 2+ ). The results obtained suggest that the elimination from blood of albumin whose structure has been altered by photoactivation can be accelerated, thereby creating favourable conditions for its application in the diagnosis of inflammatory diseases. (author)

  11. Effect of EHDP on calcium accumulation and technetium-99m pyrophosphate uptake in experimental myocardial infarction

    International Nuclear Information System (INIS)

    Buja, L.M.; Tofe, A.J.; Parkey, R.W.; Francis, M.D.; Lewis, S.E.; Kulkarni, P.V.; Bonte, F.J.; Willerson, J.T.

    1981-01-01

    Ethane-l-hydroxy-1,1-diphosphonate (EHDP) inhibits bone mineral growth. This study was performed to test the hypothesis that EHDP would interfere with the process of calcium uptake and deposition in evolving myocardial infarction and thereby influence other parameters, including technetium-99m pyrophosphate (Tc-99m PYP) uptake and scintigraphic visualization of the infarcts. Permanent occlusion of the left anterior descending coronary artery (LAD) was produced in beagles. In seven dogs, serum EHDP was maintained at 10-15 μg/ml for 24 hours by continuous i.v. infusion, and seven control dogs were infused with saline. The Tc-99m PYP was infected 2 hours before sacrifice. EHDP-treated dogs showed a mild decrease (20%) in mean calcium content of infarcted myocardium (102.4 +/- 6.4 μg [+/- SEM] per gram wet weight [n = 51] vs 126.7 +/- 9.5 [n = 49] [p -3 ] [n = 46] vs 28.9 +/- 4.3 [n = 46] [p < 0.005]) and a marked decrease (65%) in infarct-to-normal ratio (6.1 +/- 0.9 [n = 6] vs 15.9 +/- 3.7 [n = 6] [p < 0.05]). Positive relationships were demonstrated between myocardial Tc-99m PYP and calcium levels in the EHDP-treated dogs (r = 0.69) and the control dogs (r = 0.77). Infarct size and regional myocardial blood flow changes were similar in the EHDP-treated and control dogs. The average grade (0-4+) of the Tc-99m PYP myocardial scintigrams for infarcts greater than 3.5 g was 2.4 +/- 0.2 for control dogs and 1.1 +/- 0.4 for EHDP-treated dogs (p < 0.05). Thus, EHDP infusion at the dose tested produced a mild decrease in calcium accumulation in canine infarcts; however, it produced a greater reduction in Tc-99m PYP uptake in the infarcts

  12. Technetium-99m methoxyisobutylisonitrile imaging for parathyroid adenoma: relationship to P-glycoprotein or multidrug resistance-related protein expression

    International Nuclear Information System (INIS)

    Kao, Albert; Shiau, Yu-Chien; Tsai, Shih-Chuan; Wang, Jhi-Joung; Ho, Shung-Tai

    2002-01-01

    Gland size has been reported to have a major influence on localisation of parathyroid adenomas by technetium-99m methoxyisobutylisonitrile ( 99m Tc-MIBI) imaging. It has also been suggested that P-glycoprotein (Pgp) expression in parathyroid adenomas may influence localisation because false negative studies have been reported with large tumours and true positives with very small tumours. Therefore, the purpose of this study was to retrospectively evaluate the relationship between 99m Tc-MIBI parathyroid imaging results and Pgp or multidrug resistance-related protein (MRP) expression in parathyroid adenomas. Before surgery, 47 patients with large parathyroid adenomas (larger than 1.5 g) underwent early and delayed parathyroid imaging, 10 min and 2 h after intravenous injection of 99m Tc-MIBI. Immunohistochemical analyses (IHA) were performed, using multiple non-consecutive sections of the operative specimens, to detect Pgp or MRP expression. According to the results of IHA, the 34 parathyroid adenomas were separated into four groups: (1) three adenomas positive for both Pgp and MRP expression, (2) one adenoma positive for Pgp but negative for MRP expression, (3) four adenomas negative for Pgp but positive for MRP expression and (4) 39 adenomas with negative for both Pgp and MRP expression. All 39 adenomas in group 4 could be detected by 99m Tc-MIBI parathyroid imaging. None of the eight adenomas in groups 1-3 could be detected by 99m Tc-MIBI parathyroid imaging (P 99m Tc-MIBI imaging in localising parathyroid adenomas preoperatively. (orig.)

  13. Contribution to optimization of individual doses of workers in shipment of generator technetium-99m

    International Nuclear Information System (INIS)

    Fonseca, Lizandra Pereira de Souza

    2010-01-01

    The Instituto de Pesquisas Energeticas e Nucleares, IPEN, radiopharmaceuticals research and produce that are distributed throughout Brazil, currently the radiopharmaceutical with the largest number of packaged shipped per year and with the highest total activity is the 99m technetium generator. To reduce individual doses for workers involved in the production of radiopharmaceuticals was performed a study of radiological protection optimization in the shipment process of technetium generator, using the techniques: differential cost-benefit analysis, integral cost-benefit analysis, multi-attribute utility analysis and multi-criteria outranking analysis. With changes in the configuration of packed for generator dispatch and with the acquirement of a mat transporter it was possible establish 4 protection options. The attributes considered were the protection cost, collective dose, individual dose and physical effort by worker to move the package without the mat. To assess the robustness of analytical solutions found with the techniques used in the optimization we performed a sensitivity study and found that option 3 is more robust than option 1, which is no longer the analytical solution with an increase of R$ 20.000,00 the cost of protection. (author)

  14. Importance of methodology on (99m)technetium dimercapto-succinic acid scintigraphic image quality: imaging pilot study for RIVUR (Randomized Intervention for Children With Vesicoureteral Reflux) multicenter investigation.

    Science.gov (United States)

    Ziessman, Harvey A; Majd, Massoud

    2009-07-01

    We reviewed our experience with (99m)technetium dimercapto-succinic acid scintigraphy obtained during an imaging pilot study for a multicenter investigation (Randomized Intervention for Children With Vesicoureteral Reflux) of the effectiveness of daily antimicrobial prophylaxis for preventing recurrent urinary tract infection and renal scarring. We analyzed imaging methodology and its relation to diagnostic image quality. (99m)Technetium dimercapto-succinic acid imaging guidelines were provided to participating sites. High-resolution planar imaging with parallel hole or pinhole collimation was required. Two core reviewers evaluated all submitted images. Analysis included appropriate views, presence or lack of patient motion, adequate magnification, sufficient counts and diagnostic image quality. Inter-reader agreement was evaluated. We evaluated 70, (99m)technetium dimercapto-succinic acid studies from 14 institutions. Variability was noted in methodology and image quality. Correlation (r value) between dose administered and patient age was 0.780. For parallel hole collimator imaging good correlation was noted between activity administered and counts (r = 0.800). For pinhole imaging the correlation was poor (r = 0.110). A total of 10 studies (17%) were rejected for quality issues of motion, kidney overlap, inadequate magnification, inadequate counts and poor quality images. The submitting institution was informed and provided with recommendations for improving quality, and resubmission of another study was required. Only 4 studies (6%) were judged differently by the 2 reviewers, and the differences were minor. Methodology and image quality for (99m)technetium dimercapto-succinic acid scintigraphy varied more than expected between institutions. The most common reason for poor image quality was inadequate count acquisition with insufficient attention to the tradeoff between administered dose, length of image acquisition, start time of imaging and resulting image

  15. Tc-99m-hexakis(t-butylisonitrile)-technetium(I) (Tc-99m-TBI)

    International Nuclear Information System (INIS)

    Angelberger, P.; Dudczak, R.; Jones, A.G.; Lister-James, J.; Wagner-Loffler, M.; Buchheit, O.; Fally, F.

    1986-01-01

    The potassium analog (Tl-201)/sup +/ is widely used in nuclear cardiology but has inferior scintigraphic (80 keV photons), dosimetric and economic properties as compared to Tc-99m. Therefore considerable efforts have been made to develop a Tc-compound that would accumulate in the myocardium in relation to regional blood flow. This study was aimed at optimizing the preparation of Tc-TBI with n.c.a. Tc-99m, analyze and purify the product with HPLC, verify biodistribution in mice and undertake a clinical evaluation

  16. In whole blood, LPS, TNF-alpha and GM-CSF increase monocyte uptake of {sup 99m}technetium stannous colloid but do not affect neutrophil uptake

    Energy Technology Data Exchange (ETDEWEB)

    Ramsay, Stuart C. [Townsville Nuclear Medicine, Mater Hospital, Pimlico, Queensland 4812 (Australia) and School of Medicine, James Cook University, Townsville, Queensland 4811 (Australia)]. E-mail: stuart.ramsay1@jcu.edu.au; Maggs, Jacqueline [Department of Nuclear Medicine, Townsville Hospital, Townsville, Queensland 4814 (Australia); Powell, Kellie [School of Veterinary and Biomedical Sciences, James Cook University, Townsville, Queensland 4811 (Australia); School of Medicine, James Cook University, Townsville, Queensland 4811 (Australia); Barnes, Jodie [School of Veterinary and Biomedical Sciences, James Cook University, Townsville, Queensland 4811 (Australia); Ketheesan, Natkunam [School of Veterinary and Biomedical Sciences, James Cook University, Townsville, Queensland 4811 (Australia); School of Medicine, James Cook University, Townsville, Queensland 4811 (Australia)

    2006-07-15

    Introduction: {sup 99m}Technetium stannous colloid (TcSnC) is used in white cell scanning. It labels neutrophils and monocytes via phagocytosis, with uptake mediated by the phagocytic receptor CD11b/CD18 in neutrophils. Uptake of TcSnC is altered by gram-negative infection, possibly due to the endotoxin component lipopolysaccharide (LPS) or to cytokines released during infection (e.g., TNF-alpha and IFN-gamma). Endotoxemia and increased TNF-alpha levels also occur in inflammatory bowel disease. Another potential confounder in cell labeling is that sepsis patients may be treated with GM-CSF and G-CSF, which alter phagocytic cell function. This study aimed to determine how these factors affect TcSnC cellular uptake. Methods: Whole blood from six healthy volunteers was incubated with LPS, TNF-alpha, IFN-gamma, GM-CSF or G-CSF. Samples were then mixed with TcSnC. Blood was separated across density gradients and imaged using a gamma camera. Three radioactive count peaks were observed in each tube: free plasma activity, mononuclear cell uptake and neutrophil uptake. Results: Compared with controls, significant increases in mononuclear cell uptake were induced by LPS, TNF-alpha and GM-CSF stimulation. It was incidentally noted that exogenous estrogens appear to affect TcSnC labeling and may influence the neutrophil response to stimulation. Neutrophil uptake and plasma activity were not significantly affected. IFN-gamma and G-CSF had no significant effect. Conclusions: In whole blood, the effect of LPS on TcSnC monocyte uptake is different to its effect on neutrophils, consistent with previously reported differences in CD11b/CD18 expression. TNF-alpha response parallels LPS response. GM-CSF also increases TcSnC uptake by monocytes. These effects should be considered when using TcSnC for imaging purposes, as they will tend to increase monocyte labeling. Estrogens may also affect TcSnC labeling. Responses to IFN-gamma and G-CSF are consistent with previously reported effects

  17. Single photon emission computed tomography of technetium-99m tetrofosmin myocardial perfusion imaging in patients with systemic lupus erythematosus-A preliminary report

    International Nuclear Information System (INIS)

    Lin, Jen-Jhy; Hsu, Hsiu-Bao; Sun, Shung-Shung; Kao, Chia-Hung; Ho, Shung-Tai

    2003-01-01

    The purpose of this study was to evaluate the utility of single-photon emission computed tomography (SPECT) of technetium-99m tetrofosmin (Tc-99m TF) myocardial perfusion imaging to detect myocardial involvement in patients with systemic lupus erythematosus (SLE). Three groups of subjects-group 1: 25 SLE female patients with non-specific cardiac symptoms and signs, group 2: 25 female SLE patients without any cardiac symptoms and signs, and group 3: 25 female healthy controls-were evaluated by comparing rest and dipyridamole-stress Tc-99m TF myocardial perfusion SPECT. Tc-99m TF myocardial perfusion SPECT revealed perfusion defects in 88% and 40% of the cases in groups 1 and 2, respectively. However, no cases in group 3 demonstrated myocardial perfusion defects. Tc-99m TF myocardial perfusion SPECT is a useful noninvasive imaging modality to detect cardiac involvement in SLE patients with or without cardiac symptoms and signs. (author)

  18. [Situation of supply and boom of PET imaging: what is the future for technetium-99m in nuclear medicine?].

    Science.gov (United States)

    Maia, S; Ayachi Hatit, N; Paycha, F

    2011-05-01

    Molecular imaging has shown its interest in the diagnosis, staging and therapy monitoring of many diseases, especially in the field of cancer. This imaging modality can detect non-invasively early molecular changes specific to these diseases. Its expansion includes two aspects linked firstly with the advanced techniques of imaging modalities and secondly with the development of tracers as radio pharmaceuticals for imaging new molecular targets. Technetium-99m ((99m)Tc), because of its physical characteristics, its widespread availability and low cost, is the most used radionuclide in molecular imaging with the technique of single photon emission computed tomography (SPECT). Nevertheless, the current difficulty concerning the supply and the great interest of Positron Emission Tomography (PET), the "competitor" imaging modality-using molecules labelled with fluorine-18 ((18)F), legitimates the question about the future of (99m)Tc, its supremacy and the emergence of new tracer labelled with (99m)Tc. Focusing on the actual and future supply situation, the place of SPECT imaging in nuclear medicine, as well as the development of new molecules labelled with (99m)Tc is necessary to show that this radionuclide will remain essential for the speciality in the next years. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  19. Technetium-99 in lobsters from the western Irish sea

    International Nuclear Information System (INIS)

    Fegan, Mary

    1999-05-01

    Technetium-99, the most important radionuclide of technetium release to the environment, is a pure beta emitter with a half-life of 2.13 x 10(5) years. It behaves conservatively in seawater and is likely to remain available to biota for a long time. The dominant and most stable form of technetium in oxygenated seawater is the pertechnetate ion, Tco4. The principle source of radionuclide contamination of the Irish Sea has been the liquid waste discharges of low level radionuclide effluent from the spent nuclear fuel reprocessing plant at Sellafield on the Cumbria Coast. In 1994 the annual discharge authorization limit for 99Tc was increased from 10 TBq to 200 TBq. Lobster concentrates 99Tc to a high degree with concentration factors of 1x 10(3) reported in the literature. The mean 99Tc activity concentrations in lobsters caught close to Sellafield were reported to have risen by a factor of 20 in 2 years from 390 Bq/kg (wet weight) in 1993 to 8300 Bq/kg (wet weight) in 1995. This study was undertaken to determine the 99Tc activity concentration in lobsters from the western Irish Sea. Lobsters were collected from the east and north east coasts of Ireland over the period June 1997 to July 1998 and analysed using a radioanalytical method which was based on the anion-exchange seperation of technetium as pertechnetate. A gas-flow proportional counter was used to measure to 99Tc activity concentration in each sample. Technetium-99 activity concentrations were measured in the muscle from the tail, the right and the left claws and also in the green gland, the hepatopancreas and the cardiac fore-gut. The results of the measurements showed, as expected, that the 99Tc activity concentrations were not as high as those in the samples from the Cumbrian coast. The mean 99Tc activity concentrations, over the sampling period, in the tail, right and left claw muscles were 214, 124 and 136 BQ/kg (wet weight) respectively. The mean 99Tc activity concentrations in the green gland

  20. Scintigraphic evaluation of gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Park, Yong Tai; Lee, Choon Keun; Lee, Sun Wha; Choi, Woo Suk; Yoon, Yup; Lim, Jae Hoon

    1988-01-01

    Gastrointestinal bleeding remains a major diagnostic problem. Although advances have been made in the medical and surgical methods of managing gastrointestinal bleeding, the commonly employed techniques of barium radiography, endoscopy, and angiography may not successfully localize the site and define the cause of gastrointestinal bleeding. Two widely available technetium-99m-labeled radiopharmaceuticals, sulfur colloid and red blood cells are currently used in the evaluation of patients who are bleeding from the gastrointestinal tract. Surgically confirmed 19 patients with use of 99m Tc-sulfur colloid (7 cases) and 99m Tc-RBC (12 cases) were retrospectively evaluated. The overall sensitivity of scintigraphy in detection of bleeding and localization of bleeding site was 68% and 84%, respectively. The authors conclude that bleeding scintigraphy is a safe, sensitive, and non-invasive method as an effective screening test before performing angiography or surgery.

  1. Labeling of thymidine analog with an organometallic complex of technetium-99m for diagnostic of cancer: radiochemical and biological evaluation

    International Nuclear Information System (INIS)

    Santos, Rodrigo Luis Silva Ribeiro

    2007-01-01

    Thymidine analogs have been labeled with different radioisotopes due to their potential in monitoring the uncontrollable cell proliferation. Considering that the radioisotopes technetium-99m still keep a privileged position as a marker due to its chemical and nuclear properties, this dissertation was constituted by the developed of a new technique of labeling of thymidine analog with 99m Tc, by means of the organometallic complex. The aims of this research were: synthesis of the organometallic complex technetium-99m-carbonyl, thymidine labeling with this precursor, evaluation of stability, and radiochemical e biological evaluation with healthy and tumor-bearing animals. The preparation of the organometallic precursor, using the CO gas, was easily achieved, as well as the labeling of thymidine with this precursor, resulting itself a radiochemical pureness of ≥ 97% and ≥ 94%, respectively. Chromatography systems with good levels of trustworthiness were used, ensuring the qualification and quantification of the radiochemical samples. The result of in vitro testing of lipophilicity disclosed that the radiolabeled complex is hydrophilic, with a partition coefficient (log P) of -1.48. The precursor complex and the radiolabeled have good radiochemical stability up to 6 h in room temperature. The cysteine and histidine challenge indicated losses between 8 and 1 1 % for concentrations until 300 mM. The biodistribution assay in healthy mice revealed rapid blood clearance and low uptake by general organs with renal and hepatobiliary excretion. The tumor concentration was low with values of 0.28 and 0.18 %ID/g for lung and breast cancer, respectively. The results imply more studies in other tumor models or the modification of the structure of the organic molecule that act like ligand. (author)

  2. Evaluation of technetium-99m exametazime stabilised with cobalt chloride as a blood flow tracer in focal cerebral ischaemia

    Energy Technology Data Exchange (ETDEWEB)

    Gartshore, G [Wellcome Surgical Inst. and Hugh Fraser Neuroscience Labs., Glasgow Univ. (United Kingdom); Bannan, P [Wellcome Surgical Inst. and Hugh Fraser Neuroscience Labs., Glasgow Univ. (United Kingdom); Patterson, J [Wellcome Surgical Inst. and Hugh Fraser Neuroscience Labs., Glasgow Univ. (United Kingdom); Higley, B [Wellcome Surgical Inst. and Hugh Fraser Neuroscience Labs., Glasgow Univ. (United Kingdom); McCulloch, J [Wellcome Surgical Inst. and Hugh Fraser Neuroscience Labs., Glasgow Univ. (United Kingdom)

    1994-09-01

    A protocol has been devised to effectively extend the limited post-reconstitution shelf life of technetium-99m exametazime as a radiopharmaceutical for imaging cerebral blood flow (CBF) distribution. The potential of [sup 99m]Tc-exametazime stabilised with cobalt chloride for imaging CBF distribution as late as 4 h after reconstitution has been examined in ischaemic and non-ischaemic tissue in halothane-anaesthetised cats. Focal cerebral ischaemia was produced by permanent middle cerebral artery occlusion. The relationship between [sup 99m]Tc-exametazime uptake and retention and CBF (assessed with [[sup 14]C]iodoantipyrine 10 min after first radiopharmaceutical administration) was determined in the same tissue section with double label autoradiography. Over the CBF range 0 - 80 ml 100 g[sup -1] min[sup -1], the uptake of [sup 99m]Tc-exametazime (quantitatively and topographically) was linearly related to CBF irrespective of whether the [sup 99m]Tc-labelled tracer was unstabilised (and administered within 10 min of reconstitution) or was stabilised with cobalt chloride (and administered up to 240 min after reconstitution). For levels of CBF in excess of 80 ml 100 g[sup -1] min[sup -1] the excellent topographical relationship between [sup 99m]Tc-exametazime distribution and CBF is maintained but quantitatively, [sup 99m]Tc-exametazime underestimates CBF to a similar degree in animals receiving stabilised and unstabilised [sup 99m]Tc-exametazime. The presence of the stabiliser, cobalt chloride, extends greatly the period over which [sup 99m]Tc-exametazime can be used after reconstitution to generate images of CBF distribution in normal and ischaemic cerebral tissue. (orig.)

  3. Renal excretion of /sup 99m/Tc-diphosphonate in osteomalacia

    International Nuclear Information System (INIS)

    Macfarlane, J.D.; Khairi, M.R.A.; Ricciardone, M.; Wellman, H.N.; Johnston, C.C. Jr.

    1979-01-01

    Bone scans were performed on a patient with osteomalacia using /sup 99m/technetium-ethane-1-hydroxy-1,1-diphosphonate (/sup 99m/Tc-EHDP). The renal excretion of /sup 99m/Tc-EHDP was measured and the results were compared with those obtained in 4 patients with idiopathic osteoporosis

  4. Stabilized alcohol solution of reducing salt formulations for use in preparing radioisotope labelled scanning agents: liver scanning technetium-99m colloid and method of preparation

    International Nuclear Information System (INIS)

    1980-01-01

    The preparation of a radiolabelled scanning agent for imaging reticuloendothelial organs, including the liver and spleen, is described. It consists of a sup(99m)Tc labelled colloid of a metal ion salt reductant, such as SnCl 2 , TiCl 3 , CrCl 2 or FeCl 2 , and an anhydrous non-oxidising organic solvent, such as diethyl ether, ethanol or another aliphatic alcohol. Examples are given of the effects of varying the pH, the metal ion salt reductant concentration, the eluate and solvent volumes and the temperature of the radiopharmaceutical on the tagging efficiency and organ distribution in mice and rabbits. (U.K.)

  5. Graves' disease in an adolescent with dual congenital ectopia and no orthotopic thyroid gland identified by Tc-99m-pertechnetate SPET/CT imaging.

    Science.gov (United States)

    Qiu, Zhong-Ling; Xue, Yan-Li; Shen, Chen-Tian; Zhu, Rui-Sen; Luo, Quan-Yong

    2013-01-01

    This is the first case of Graves' disease in an adolescent with lingual and prelaryngeal dual congenital ectopia and no orthotopic thyroid gland identified by technetium-99m-pertechnetate (99mTcO-4) SPET/CT imaging in a 15 years old boy. After 8 weeks treatment with methimazole, Graves' disease subsided. Fine needle aspiration cytology of the mass revealed the normal colloid and normal follicular cells without an atypia or lymphoid elements, suggesting a benign ectopic thyroid gland. In conclusion, there is no report in the literature with DETT lingual and prelaryngeal absence of orthotopic thyroid tissue and Graves' disease as in our case. This case also highlights the potential ascendancy of 99mTcO-4 SPET/CT in diagnosing the DETT.

  6. Evolution of technetium-99m-HMPAO SPECT and brain mapping in a patient presenting with echolalia and palilalia.

    Science.gov (United States)

    Dierckx, R A; Saerens, J; De Deyn, P P; Verslegers, W; Marien, P; Vandevivere, J

    1991-08-01

    A 78-yr-old woman presented with transient echolalia and palilalia. She had suffered from Parkinson's disease for 2 yr. Routine laboratory examination showed hypotonic hyponatremia, but was otherwise unremarkable. Brain mapping revealed a bifrontal delta focus, more pronounced on the right. Single photon emission computed tomography (SPECT) of the brain with technetium-99m labeled d,l hexamethylpropylene-amine oxime (99mTc-HMPAO), performed during the acute episode showed relative frontoparietal hypoactivity. Brain mapping performed after disappearance of the echolalia and palilalia, which persisted only for 1 day, was normal. By contrast, SPECT findings persisted for more than 3 wk. Features of particular interest in the presented patient are the extensive defects seen on brain SPECT despite the absence of morphologic lesions, the congruent electrophysiologic changes and their temporal relationship with the clinical evolution.

  7. Technetium-99m methoxyisobutylisonitrile imaging for parathyroid adenoma: relationship to P-glycoprotein or multidrug resistance-related protein expression

    Energy Technology Data Exchange (ETDEWEB)

    Kao, Albert [Departments of Nuclear Medicine and Medical Research, China Medical College Hospital, No. 2, Yuh-Der Road, Taichung 404 (Taiwan); Shiau, Yu-Chien [Department of Nuclear Medicine, Far Eastern Memorial Hospital, Institute of Biomedical Engineering, College of Electrical Engineering, National Taiwan University, Taipei (Taiwan); Tsai, Shih-Chuan [Department of Nuclear Medicine, Show-Chwan Memorial Hospital, Chunghua (Taiwan); Wang, Jhi-Joung [Department of Medical Research, Chi-Mei Medical Center, Tainan (Taiwan); Ho, Shung-Tai [School of Medicine, National Defense Medical Center, Taipe (Taiwan)

    2002-08-01

    Gland size has been reported to have a major influence on localisation of parathyroid adenomas by technetium-99m methoxyisobutylisonitrile ({sup 99m}Tc-MIBI) imaging. It has also been suggested that P-glycoprotein (Pgp) expression in parathyroid adenomas may influence localisation because false negative studies have been reported with large tumours and true positives with very small tumours. Therefore, the purpose of this study was to retrospectively evaluate the relationship between {sup 99m}Tc-MIBI parathyroid imaging results and Pgp or multidrug resistance-related protein (MRP) expression in parathyroid adenomas. Before surgery, 47 patients with large parathyroid adenomas (larger than 1.5 g) underwent early and delayed parathyroid imaging, 10 min and 2 h after intravenous injection of {sup 99m}Tc-MIBI. Immunohistochemical analyses (IHA) were performed, using multiple non-consecutive sections of the operative specimens, to detect Pgp or MRP expression. According to the results of IHA, the 34 parathyroid adenomas were separated into four groups: (1) three adenomas positive for both Pgp and MRP expression, (2) one adenoma positive for Pgp but negative for MRP expression, (3) four adenomas negative for Pgp but positive for MRP expression and (4) 39 adenomas with negative for both Pgp and MRP expression. All 39 adenomas in group 4 could be detected by {sup 99m}Tc-MIBI parathyroid imaging. None of the eight adenomas in groups 1-3 could be detected by {sup 99m}Tc-MIBI parathyroid imaging (P<0.05). It is concluded that not only the size of parathyroid adenomas but also significant Pgp or MRP expression limits the sensitivity of {sup 99m}Tc-MIBI imaging in localising parathyroid adenomas preoperatively. (orig.)

  8. Successful application of technetium-99m-labeled octreotide acetate scintigraphy in the detection of ectopic adrenocorticotropin-producing bronchial carcinoid lung tumor: a case report

    Directory of Open Access Journals (Sweden)

    Fallahi Babak

    2010-10-01

    Full Text Available Abstract Introduction The diagnostic efficacy of somatostatin receptor scintigraphy labeling with 111 indium in the localization of tumors has been assessed in a limited number of patients with contradictory outcomes. Here, we describe the case of a patient with an ectopic adrenocorticotropic hormone-producing bronchial carcinoid tumor diagnosed preoperatively using technetium-99m-labeled octreotide acetate scintigraphy. Case presentation A 29-year-old Asian man presented to our hospital with the typical clinical features of Cushing's syndrome, which he had had for a duration of 18 months. The results of a biochemical evaluation revealed he had adrenocorticotropic hormone-dependent Cushing's syndrome. The results of a spiral abdominal computed tomography scan showed he had bilateral adrenal hypertrophy. A magnetic resonance image of the patient's brain showed he had a normal hypophysis. Whole body technetium-99m-labeled octreotide acetate scintigraphy was performed to check for the presence of an ectopic adrenocorticotropic hormone-producing tumor. The scan results showed a small focal increase in uptake in the lower lobe of our patient's right lung, just above his diaphragm. A spiral chest computed tomography scan also revealed a small non-specific lesion in the same region. A transthoracic biopsy was then performed. Pathological evaluation confirmed the diagnosis of a carcinoid tumor, of the adrenocorticotropic hormone-producing type. After surgical removal, the patient's symptoms resolved and significant clinical improvement was achieved. Conclusions This case report shows that technetium-99m-labeled octreotide acetate scintigraphy can effectively detect an ectopic adrenocorticotropic hormone-producing bronchial carcinoid.

  9. Technetium-99m extraction and transport across tri-n-octylamine-xylene based supported liquid membranes

    International Nuclear Information System (INIS)

    Ashraf Chaudry, M.; Ahmad, B.

    1996-01-01

    The nuclear properties of 99m Tc radionuclide are ideal for organ imaging. Study of the technetium transport across supported liquid membranes has been performed to get data for its separation from other elements. Tri-n-octylamine diluted in xylene was used to constitute the liquid membranes, supported in polypropylene microporous films. Stripping on the product solution side was performed with dilute NaOH solutions. The effect of sulphuric acid, nitric acid and hydrochloric acid in the feed on transport of 99m Tc as TcO 4 - ions has been studied. The permeability of the given ions determined from kinetic activity data has been found to be in the order of PH 2 SO 4 >PHCl>PHNO 3 . The flux values have been calculated based on this permeability data. The increase in carrier concentration has shown an increase in flux and permeability values to a given optimum concentration. The increase in temperature has been found to reduce the transport of Tc ions. The optimum conditions for transport of 99m Tc for the given acid concentration have been determined. Mechanism of Tc ion transport has also been provided based on chemical reactions involved at the membrane interfaces and uptake of Tc ions by the membrane. MoO 4 2- ions do not permeate through membrane under optimum conditions of transport for TcO 4 2 - ions from H 2 SO 4 solution. (author). 12 refs., 20 figs., 1 tab

  10. Measurement of technetium-99 in Marshall Islands soil samples by ICP-MS

    International Nuclear Information System (INIS)

    Tagami, K.; Uchida, S.; Hamilton, T.; Robison, W.

    2000-01-01

    Extraction techniques for recovery of technetium-99 ( 99 Tc) for Inductively Coupled Plasma Mass Spectrometry (ICP-MS) measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (M1) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for 99 Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the 99 Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The 99 Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq g -1 dry weight (dw). The limit of detection for 99 Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq g -1 dw under standard operating conditions

  11. A comparative technetium 99m hexamethylpropylene amine oxime SPET study in different types of dementia

    Energy Technology Data Exchange (ETDEWEB)

    Habert, M O; Piketty, M L; Askienazy, S [Centre Hospitalier Sainte-Anne, 75 - Paris (France). Dept. de Medecine Nucleaire; Spampinato, U; Mas, J L; Recondo, J de; Rondot, P [Centre Hospitalier Sainte-Anne, 75 - Paris (France). Dept. de Neurologie; Bourdel, M C [Centre Hospitalier Sainte-Anne, 75 - Paris (France). Dept. de Psychiatrie

    1991-01-01

    Regional cerebral perfusion was evaluated by single photon emission tomography (SPET) using technetium 99m hexamethylpropylene amine oxime ({sup 99m}Tc-HMPAO) as a tracer, in 13 control subjects and 44 age-matched patients suffering from dementia of the Alzheimer's type (DAT, n=19) presumed Pick's disease (n=5), idiopathic Parkinson's disease with dementia (DPD, n=15) and progressive supranuclear palsy (PSP, n=5), HMPAO uptake was measured in the superior frontal, inferior frontal, parietal, temporal and occipital cortices, and the perfusion values were expressed as cortical/cerebellar activity ratios. As compared with controls, tracer uptake ratios in the DAT group were signficantly reduced over all cortical regions, with the largest defects in the parieto-temporal and superior frontal cortices. A marked hypoperfusion affecting the superior and inferior frontal cortices was found in Pick's diesease, whereas a mild but significant hypoperfusion was observed only in the superior frontal cortex of patients with PSP. In the DPD group, HMPAO uptake was significantly reduced in the parietal, temporal and occipital cortices, but not in the frontal cortex. These results show that DAT and DPD share the opposite anteroposterior HMPAO uptake defect as compared with the Pick's and PSP groups. (orig.).

  12. Investigations on the structures of sup(99m)Tc and 113Sn pyrophosphate complexes and of sup(99m)Tc and 113Sn ethane hydroxy diphosphate complexes

    International Nuclear Information System (INIS)

    Hohloch, M.

    1980-01-01

    The complex formation of double labelling of bivalent 113 Sn and reduced, quadrovalent sup(99m)Tc with pyrophosphate (PPi) or ethane hydroxy diphosphorate (EHDP) has been investigated by means of in vivo distribution in the rat. The molar rates of sup(99m)Tc and 113 Sn to PPi resp. EHDP, as well as the pH-value and the initial concentration is varied. Furthermore, both elements were oxidized with H 2 O 2 in the alkaline medium. Four typical sup(99m)Tc and two typical 113 Sn in-vivo distribution patterns can be differentiated: 1. Pertechnetate, characterized by a strong enrichment in the stomach, forms when all Sn-II has been oxidized to Sn-IV in the preparation. 2. One bone-seeking 113 Sn-II PPi (EHDP) complex and a sup(99m)Tc-IV PPi (EHDP) complex each, which are formed at least equimolar ratio of Sn to PPi (EHDP) and suffiently high concentration of PPi (EHDP) in the physiological pH-value. 3. A non-bone-seeking sup(99m)Tc-IV compound, which is enriched in the kidneys instead, is formed in the weakly alkaline medium or at low PPi (EHDP) concentration. This is probably monomeric technetium dioxide dihydrate. 4. A sup(99m)Tc as well as a Sn colloid is formed at deficient ligand concentration (PPi or EHDP to Sn). The chemical composition of the complexes is discussed the possible reaction courses are illustrated in the following diagrams. (orig./MG) [de

  13. Comparison of carrier-added [99mTc] EDTMP and carrier-free preparations of [99mTc] EDTMP and [99mTc] DPD

    International Nuclear Information System (INIS)

    Krcal, A.; Kletter, K.; Dudczak, R.; Pirich, C.; Mitterhauser, M.

    2002-01-01

    Full text: High uptake of bone-seeking radiopharmaceuticals in malignant bone lesions is a prerequisite for adequate bone scanning. Visual image analysis is impaired due to high soft-tissue activity with currently available [ 99m Tc]-EDTMP-kits. This study aimed to compare carrier-added [ 99m Tc]-EDTMP with carrier-free [ 99m Tc]-EDTMP and [ 99m Tc]-DPD preparations in clinical routine. 15 μg and 150 μg perrhenic acid respectively were added to [ 99m Tc]-pertechnetate (>6 GBq in 3 ml phys. saline). The solution was then transferred into a vial, containing 1 mg of EDTMP, 3.6 mg stannous(II)chloride and 10 mg ascorbic acid under inert conditions. Under vigorous stirring the reaction mixture was heated to 45 o C for 10 min. After cooling down to room temperature the labelling mixture was sterile filtrated (millipore 0.22 μm). Quality control was performed using radio-ITLC (Whatman SG; acetone or ethanol: R f perrhenate/pertechnetate 0.87, colloid/product 0.05; phys. saline: R f colloid 0.00, perrhenate/pertechnetate and product 0.9) allowing rapid and efficient assessment of the product. Carrier free [ 99m Tc]-EDTMP and [ 99m Tc]-DPD were prepared according to instructions of the manufacturer. Clinical studies were performed in 29 patients according to a routine bone scanning protocol by injecting 700-800 MBq of the respective tracer and whole body imaging 3 h thereafter. Radiochemical purity and radiochemical yield relied on various parameters such as concentration of carrier and reducing agent and reaction conditions (pH, reaction time, temperature). Means of the labelling yield were 22 % for the preparation using 150 μg of carrier (5 preparations), 80 % for the preparation using 15 μpg of carrier (10 preparations) and 91 % for the carrier free products (5 preparations). Radiochemical purity was >96 % in all experiments. Colloid was formed in very low amounts, and was completely removed by sterile filtration. In clinical studies quantitative analysis

  14. Technetium compounds

    International Nuclear Information System (INIS)

    Murphy, C.A. de; Ferro F, G.

    2003-01-01

    The first radiopharmaceuticals of 99m Tc, also call of 'first generation' as colloids, aggregates and simple complexes were developed with relative easiness without it was necessary a wide understanding of its chemical structure. In the radiopharmaceuticals of 'second generation' were included those derived of the HIDA for hepatobiliary images, MAG3 and EC for images of tubular renal de purification, HMPAO and ECD for images of cerebral perfusion and MIBI and tetrofosmin for images of heart perfusion, that which implies a bigger demand in terms of the chemical knowledge. At the moment, we can affirm that the future of the radiopharmaceuticals of 99m Tc is based on the use of small and relevant biomolecules with high biological activity that allow the visualization in vivo of specific receiving sites and/or its expression in diverse pathologies. It is for it that with the 'third generation' is necessary a wide one knowledge of the chemistry of the technetium that allows the design and characterization of highly specific bio complexes. In this book, although focused mainly to the chemistry of the Tc, a brief revision is also presented on the main biologically active molecules that, coordinated the 99m Tc, present a high recognition In vivo for specific receivers. (Author)

  15. Preparation and in vivo biological investigations on a novel radioligand for bone scanning: technetium-99m-labeled zoledronic acid derivative

    International Nuclear Information System (INIS)

    Lin Jianguo; Qiu Ling; Cheng Wen; Luo Shineng; Ye Wanzhong

    2011-01-01

    Introduction: To enable imaging at an earlier time after injection, a radiopharmaceutical with higher affinity for bone, larger ratio of bone-to-soft tissue uptake and more rapid clearance from blood is required. The nature of diphosphonic acid is a key factor to determine the advantages of the radiopharmaceuticals. The purpose of this study is to optimize the linker chain between the imidazolyl and geminal diphosphonate group in the zoledronic acid (ZL) to develop novel single photon emission computed tomography (SPECT) bone imaging agent. Methods: A novel ZL derivative, 1-hydroxy-3-(1H-imidazol-1-yl)propane-1,1-diyldiphosphonic acid (IPrDP), was successfully prepared and labeled with 99m Tc in a high labeling yield. Biodistribution of 99m Tc-IPrDP and 99m Tc-ZL in normal mice were studied and compared. SPECT bone scanning was performed on the rabbit and a series of dynamic and static images were recorded by Philips SKY Light emission computed tomography. Results: In the biodistribution studies, 99m Tc-IPrDP exhibits significant advantages on the bone resorption and the clearance from soft tissues compared with 99m Tc-ZL. Kinetics of blood clearance in mice showed that T 1/2α and T 1/2β of 99m Tc-IPrDP were 1.47 min and 46.47 min, while those of 99m Tc-ZL were 2.28 and 52.63 min respectively. Excellent images of the rabbit skeleton can be quickly obtained for 99m Tc-IPrDP, which was faster than 99m Tc-ZL and the clinically widely used bone imaging agent 99m Tc-MDP (technetium-99m labeled with methylenediphosphonate). Conclusions: 99m Tc-IPrDP possesses excellent characteristics for the potential application as a novel bone scanning agent.

  16. In vivo detection of multidrug-resistant (MDR1) phenotype by technetium-99m sestamibi scan in untreated breast cancer patients

    International Nuclear Information System (INIS)

    Del Vecchio, S.; Ciarmiello, A.; Potena, M.I.; Carriero, M.V.; Mainolfi, C.; Botti, G.; Thomas, R.; Cerra, M.; D'Aiuto, G.; Tsuruo, T.; Salvatore, M.

    1997-01-01

    Technetium-99m sestamibi is a transport substrate recognised by the multidrug-resistant P-glycoprotein (Pgp). To test whether 99m Tc-sestamibi efflux is enhanced in breast carcinomas overexpressing Pgp, we determined the efflux rates of 99m Tc-sestamibi and Pgp levels in tumours from 30 patients with untreated breast carcinoma. Patients were intravenously injected with 740 MBq of 99m Tc-sestamibi and underwent a 15-min dynamic study followed by the acquisition of static planar images at 0.5, 1, 2 and 4 h. Tumour specimens were obtained from each patient 24 h after 99m Tc-sestamibi scan and Pgp levels were determined using 125 I-MRK16 monoclonal antibody and in vitro quantitative autoradiography. All breast carcinomas showed high uptake of 99m Tc-sestamibi and data from region of interest analysis on sequential images were fitted with a monoexponential function. The efflux rates of 99m Tc-sestamibi, calculated from decay-corrected time-activity curves, ranged between 0.00121 and 0.01690 min -1 and were directly correlated with Pgp levels measured in the same tumours (r=0.62; P 99m Tc-sestamibi efflux from tumours of group A was 2.7 times higher than that observed in tumours of group B (0.00686 ±0.00390 min -1 vs 0.00250 ±0.00090 min -1 , P 99m Tc-sestamibi showed a sensitivity and a specificity of 80% and 95%, respectively. In conclusion, the efflux rate of 99m Tc-sestamibi may be used for the in vivo identification of the multidrug resistant (MDR1) phenotype in untreated breast cancer patients. (orig.). With 7 figs., 3 tabs

  17. Measurement of technetium-99 in Marshall Islands soil samples by ICP-MS

    Science.gov (United States)

    Tagami; Uchida; Hamilton; Robison

    2000-07-01

    Extraction techniques for recovery of technetium-99 (99Tc) for Inductively Coupled Plasma Mass Spectrometry (ICP-MS) measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (MI) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for 99Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the 99Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The 99Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq g(-1) dry weight (dw). The limit of detection for 99Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq g(-1) dw under standard operating conditions.

  18. Radiopharmacokinetic data for 99mTc-ABP - A new radiopharmaceutical for bone scanning: Comparison with 99mTc-MDP

    International Nuclear Information System (INIS)

    Murphy, Consuelo Arteaga de; Melendez-Alafort, Laura; Montoya-Molina, Carlos E.; Sepulveda-Mendez, Jesus

    1997-01-01

    Technetium-99m-labeled alendronate is a new radiopharmaceutical for bone scanning developed under strict quality control at the INNSZ. The purpose of this work was to compare the radiopharmacokinetic data and the dosimetry of 99m Tc-ABP and 99m Tc-MDP in 10 volunteers, after it was tested in laboratory animals. 99m Tc-ABP has shorter mean residence time (MRT) and t (1(2)) β; is less protein bound; has a higher renal clearance; smaller Vdss, and similar bone uptake at 1 and 2 h. 99m Tc-ABP gives less radiation exposure to the patient with a 740 MBq dose, and the quality of the bone scan is excellent. 99m Tc-ABP is a better radiopharmaceutical than 99m Tc-MDP for bone scanning

  19. Comparison of differential renal function using technetium-99m mercaptoacetyltriglycine (MAG3) and technetium-99m dimercaptosuccinic acid (DMSA) renography in a paediatric population

    Energy Technology Data Exchange (ETDEWEB)

    Ritchie, Gillian; Wilkinson, Alistair G. [Royal Hospital for Sick Children, Edinburgh (United Kingdom); Prescott, Robin J. [University of Edinburgh Medical School, Medical Statistics Unit, Public Health Sciences, Edinburgh (United Kingdom)

    2008-08-15

    In children who have undergone both {sup 99m}Tc-DMSA and {sup 99m}Tc-MAG3 studies for the assessment of differential renal function (DRF) and drainage, respectively, we have noticed good agreement between the calculated DRF values, and hypothesized that there is no significant difference in DRF values calculated from these tests. Therefore, both tests may not always be necessary. To determine whether there is a statistically significant difference between DRF values calculated using {sup 99m}Tc-DMSA and those calculated using {sup 99m}Tc-MAG3. We retrospectively identified children imaged with {sup 99m}Tc-DMSA and {sup 99m}Tc-MAG3. We recorded DRF values, age, indication, and renal pelvis diameter. For the {sup 99m}Tc-DMSA studies we recorded the imaging time after injection. For the {sup 99m}Tc-MAG3 studies we recorded the delay between injection and data acquisition, diuretic use and evidence of delayed drainage or reflux. We identified 100 episodes in 92 children where both {sup 99m}Tc-DMSA and {sup 99m}Tc-MAG3 scans had been performed within a few days. The commonest indication was urinary tract infection or pelviureteric junction obstruction. The mean age of the children was 6.96 years. A significant but clinically acceptable trend was seen between abnormal DRF and difference between tests. A significant link was found with the difference between tests and the time of imaging after DMSA injection, and also with scarring. No significant effect was caused by renal pelvis dilatation, delayed drainage, frusemide administration, or delayed {sup 99m}Tc-MAG3 imaging. If a {sup 99m}Tc-MAG3 study has been performed then a {sup 99m}Tc-DMSA study is unnecessary provided DRF is normal on the {sup 99m}Tc-MAG3 study and there is no scarring. A change in practice would lead to considerable savings in time, cost and radiation burden. (orig.)

  20. 99m-technetium tetrofosmin and 99mTc-methylene diphosphonate in pre-surgical breast cancer

    International Nuclear Information System (INIS)

    Piperkova, E.; Gavrilov, I.; Timcheva, K.; Garanina, Z.; Aleksandrova, E.; Katerinski, K.; Dimitrova, M.

    2004-01-01

    Full text: The aim of this study was to assess the role of the Tc-99m Tetrofosmin (TF) in conjunction with Tc-99m methylenediphosphonate (MDP) in pre-surgical breast cancer (BC) staging. Thirty-six female patients, age range was 32-70 years (average 51.45 years), where the clinical examination, mammography (MG) and fine-needle aspiration cytology were inconclusive were subjected to Tc-99m TF Scintimammography (SMM). All the patients were examined in a specialized breast clinic by experienced surgeons and radiologists. Of the 36 patients, 24 had hyperdense breasts, 8 had undergone lumpectomy or mastectomy due to cancer in one of the breasts and were included in the present study because of suspicion of lesion in the contra lateral breast, 2 had palpable axillary lymph nodes (LN) but no palpable breast lump and 2 patients were of mastitis carcinomatosis. All biopsies were histopathologically verified 740 MBq of Tc-99m TF (Myoview-Amersham) was injected in the arm opposite to the side of the breast lesion. In patients with bilateral breast lesions (BL) radiopharmaceutical was injected in a pedal vein. Planar imaging in prone position was done 10-15 min later. Two lateral views of the left and right breasts including axilla were acquired followed by an anterior view in supine position with arm in an upright position so as to include both breasts and axillary region in the field of imaging view. Imaging was done using a large field of view single-head gamma camera (Diacam-Siemens) coupled with low-energy high-resolution collimator. In patients with locally advanced BC who were to receive pre-operative neo-adjuvant chemotherapy, cardiac GATED SPECT was also acquired using standard protocol. After few days, Tc-99m MDM scintimammography and whole-body bone scintigraphy was also performed. SMM, using the same acquisition protocol as with 99mTc-TF, was done 5-10 min after intravenous injection of 555-740 MBq 99mTc MDP. Standard WBBS was acquired two to three hours later. SMM

  1. Quantitative analysis of acute myocardial infarction using single photon emission computed tomography using technetium-99m pyrophosphate

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, Yasushi; Kokubu, Tatsuo; Murase, Kenya; Hamamoto, Ken; Itoh, Taketoshi; Doiuchi, Junji; Ochi, Takaaki

    1986-09-01

    The usefulness of single photon emission computed tomography (SPECT) using technetium-99m pyrophosphate (/sup 99m/Tc-PPi) was evaluated in 15 patients with acute myocardial infarction. SPECT was performed with a rotating gamma camera after conventional planar images were made. Infarct size was measured from transaxial images of myocardial pyrophosphate uptakes. In each slice, the boundary was defined by subtracting 70 percent of the maximal counts and the number of voxels automatically counted. This subtraction rate was determined by phantom study and by compraing SPECT using /sup 99m/Tc-PPi with thallium-201-gated myocardial scintigraphy (/sup 201/Tl gated SPECT). The planar images showed diffuse uptakes in two of the 15 patients, and in these cases it was difficult to detect the infarct site. In contrast, SPECT images clearly imaged the infarct site consistent with the electrocardiographic findings, and they were definitely separated from the uptakes in the bones in all cases. Infarct size, ranging from 3.4 ml to 78.3 ml, correlated well with cumulative creatine kinase release (r = 0.84, p < 0.01, y = 772x + 13900). Correlation of infarct size with peak serum creatine kinase level was also significant (r = 0.66, p < 0.01, y = 10.6x + 693). In conclusion, SPECT with /sup 99m/Tc-PPi is a useful means of investigating the spatial distribution of pyrophosphate uptake and of evaluating the size of myocardial infarction.

  2. Evaluation of inflammatory processes in temporomandibular joint employing technetium-99m-labelled autologous leukocytes in an animal model; Avaliacao de processos inflamatorios na articulacao temporomandibular empregando leucocitos autologos marcados com tecnecio-99m em modelo animal

    Energy Technology Data Exchange (ETDEWEB)

    Brasileiro, Claudia Borges [Centro Universitario Newton Paiva, Belo Horizonte, MG (Brazil)]. E-mail: claudiabb.prof@newtonpaiva.br; cbbrasileiro@bol.com.br; Cardoso, Valbert Nascimento; Ruckert, Bianca [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Faculdade de Farmacia; Campos, Tarcisio Passos Ribeiro de [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Escola de Engenharia. Dept. de Engenharia Nuclear

    2006-07-15

    Objective: the present study was aimed at identifying temporomandibular joint inflammatory processes employing technetium-99m hexamethyl propylene amine oxime (99mTc-HMPAO)-labeled autonomous leukocytes. Materials and methods: we have utilized an experimental model of arthritis induction in ten adult male New Zealand rabbits by means of ovalbumin intra-articular injection into each left temporomandibular joint. For control purposes, saline solution was injected. After leukocytes radiolabeling with 99mTc-HMPAO and injection into rabbits, scintigraphic images were obtained. Results: a higher 99mTc-HMPAO-leukocytes uptake was observed in left temporomandibular joint in comparison with the contralateral joint. Wilcoxon non-parametric test was applied for statistical analysis. There was a statistically significant difference between counts of radioactivity per minute in the inflamed joint and the contralateral one (p = 0.0073). Conclusion: the method employing 99mTc-HMPAO-labelled autologous leukocytes allows an early and accurate detection of inflammatory processes, contributing to the adoption of a therapeutic conduct for patients before structural alterations have occurred. (author)

  3. Biological evaluation of 99m Tc-N-(3-bromo-trimethyl-acetanilide)-iminodiacetic acid (99mTc mebrofenin) as hepatobiliary radiopharmaceutical

    International Nuclear Information System (INIS)

    Hamada, E.S.

    1994-01-01

    Technetium-99 m-N-(3-bromo-2,4,6-trimethyl acetanilide) iminodiacetic acid ( 99m Tc-Mebrofenin) has been described as having optimal properties as hepatobiliary radiopharmaceutical. This paper describes the synthesis, radiopharmaceutical preparation and biological distribution of new labeled compound. The biodistribution study of 99m Tc-Mebrofenin- was carried out in normal mice. The specificity for hepatobiliary excretion blood clearance and cumulative biliary excretion were evaluated in normal and cirrhotic rats. (author). 5 refs, 3 figs, 3 tabs

  4. Effect of ischemia and postischemic dysfunction on myocardial uptake of technetium-99m-labeled methoxyisobutyl isonitrile and thallium-201

    International Nuclear Information System (INIS)

    Sinusas, A.J.; Watson, D.D.; Cannon, J.M. Jr.; Beller, G.A.

    1989-01-01

    The myocardial uptake of a new technetium-99m-labeled myocardial perfusion agent, methoxyisobutyl isonitrile (Tc-99m MIBI), and thallium-201 was correlated with microsphere flow in an open chest canine model of low coronary flow and postischemic dysfunction. Eighteen dogs were given an injection of thallium-201 (0.5 mCi) and Tc-99m MIBI (5 mCi) either after 40 min of partial left anterior descending artery occlusion (Group I, 10 dogs) or during reperfusion after 15 min of left anterior descending artery occlusion (Group II, 8 dogs). Regional dysfunction was documented during injection in both groups by quantitative two-dimensional echocardiography. Regional blood flow was assessed by radiolabeled microspheres. The heart was excised 15 min after radionuclide injection and the left ventricle divided into 96 segments for gamma well counting. Among Group I dogs, central ischemic thallium-201 and Tc-99m MIBI activity (expressed as a percent of the activity in the corresponding nonischemic zone) was comparable, respectively, for endocardial (54 +/- 17% and 52 +/- 17%), mid-wall (71 +/- 20% and 69 +/- 17%) and epicardial (89 +/- 13% and 94 +/- 9%) segments and increased proportionally with flow. There was a good linear correlation among these endocardial segments between flow and both thallium-201 (r = 0.78) and Tc-99m MIBI (r = 0.85) activity. Among Group II dogs, central ischemic endocardial flow (59 +/- 14%) was comparable to thallium-201 (70 +/- 18%) and Tc-99m MIBI (74 +/- 12%) activity. Similarly, relative endocardial flow in the intermediate ischemic region (71 +/- 11%) was comparable to thallium-201 (77 +/- 11%) and Tc-99m MIBI (81 +/- 10%) activity. Thus, myocardial uptake of Tc-99m MIBI and thallium-201 is comparable under conditions of low coronary flow and postischemic dysfunction and closely parallels flow alterations

  5. Brain single-photon emission tomography with technetium-99m hexamethylpropylene amine oxime in adolscents with intial-stage schizophrenia

    International Nuclear Information System (INIS)

    Batista, J.F.; Galiano, M.C.; Torres, L.A.; Hernandez, M.C.; Sosa, F.; Perera, A.; Perez, M.

    1995-01-01

    The objective of this study was to search for regional cerebral blood flow (rCBF) abnormalities in adolescents with initial-stage schizophrenia by means of brain single-photon emission tomography (SPET) using technetium-99m hexamethylpropylene amine oxime (HMPAO). SPET studies were performed on a homogeneous sample of 15 carefully selected adolescents with a recent diagnosis of schizophrenia, and without previous electroconvulsive or antipsychotic drug treatment. Computed tomography (CT) and electro-encephalographic (EEG) studies were performed in all patients. Qualitative and semiquantitative analysis of 99m Tc-HMPAO SPET studies showed an impaired rCBF in 12 patients (80%). The most common pattern was a decreased uptake of 99m Tc-HMPAO in the frontal lobes, usually in the left hemisphere. Conventional and quantitative EEG was positive in 12 (80%) and 15 (100%) patients, respectively. CT findings were positive in two patients (13%). There was a high level of concordance between SPET and EEG results and between SPET and clinical features (P > 0.05). This study suggests that previously untreated patients in the first stages of schizophrenia present functional abnormalities that are revealed by brain SPET. (orig.)

  6. Chemical Speciation of Long-lived Radionuclide Technetium-99 and its Environmental Behaviour

    DEFF Research Database (Denmark)

    Shi, Keliang

    issue for understanding its fate and behaviour in ecosystem. This thesis aims to develop series of analytical methods for rapid and accurate determination of total 99Tc in environmental samples (e.g., seaweed, soil, and seawater), as well as speciation analysis of 99Tc in seaweeds. The application of 99...... - sorption at different concentrations of H+ was deduced. With the application of two small TEVA columns (1.5 mL for each), decontamination factors of >104 for molybdenum and >105 for ruthenium and recovery of 60-95% for technetium were achieved for different environmental samples. An absolute detection...

  7. Experimental study and quality control of a technetium-99 generator

    International Nuclear Information System (INIS)

    Jimeno de Osso, F.

    1981-01-01

    The performarce of a generator of technetium-99m to be used in nuclear medicine is studied. The most interesting characteristic of this generator is the use of a U-shaped chromatographuc column so as to improve its efficiency and design without increasing the weight of its shield. With the aim of improving certain aspects of the generator, molibdenum-99 was applied to adecuate pH, pirogens were removed from the column set up before application, application was effected on a dry column, the smallest alumina particles were separated on the column, etc. The most important parameters of an isotopic generator are studied, and the corresponding quality controls performed. (author)

  8. Different uptake of 99mTc-ECD adn 99mTc-HMPAO in the same brains: analysis by statistical parametric mapping.

    Science.gov (United States)

    Hyun, Y; Lee, J S; Rha, J H; Lee, I K; Ha, C K; Lee, D S

    2001-02-01

    The purpose of this study was to investigate the differences between technetium-99m ethyl cysteinate dimer (99mTc-ECD) and technetium-99m hexamethylpropylene amine oxime (99mTc-HMPAO) uptake in the same brains by means of statistical parametric mapping (SPM) analysis. We examined 20 patients (9 male, 11 female, mean age 62+/-12 years) using 99mTc-ECD and 99mTc-HMPAO single-photon emission tomography (SPET) and magnetic resonance imaging (MRI) of the brain less than 7 days after onset of stroke. MRI showed no cortical infarctions. Infarctions in the pons (6 patients) and medulla (1), ischaemic periventricular white matter lesions (13) and lacunar infarction (7) were found on MRI. Split-dose and sequential SPET techniques were used for 99mTc-ECD and 99mTc-HMPAO brain SPET, without repositioning of the patient. All of the SPET images were spatially transformed to standard space, smoothed and globally normalized. The differences between the 99mTc-ECD and 99mTc-HMPAO SPET images were statistically analysed using statistical parametric mapping (SPM) 96 software. The difference between two groups was considered significant at a threshold of uncorrected P values less than 0.01. Visual analysis showed no hypoperfused areas on either 99mTc-ECD or 99mTc-HMPAO SPET images. SPM analysis revealed significantly different uptake of 99mTc-ECD and 99mTc-HMPAO in the same brains. On the 99mTc-ECD SPET images, relatively higher uptake was observed in the frontal, parietal and occipital lobes, in the left superior temporal lobe and in the superior region of the cerebellum. On the 99mTc-HMPAO SPET images, relatively higher uptake was observed in the medial temporal lobes, thalami, periventricular white matter and brain stem. These differences in uptake of the two tracers in the same brains on SPM analysis suggest that interpretation of cerebral perfusion is possible using SPET with 99mTc-ECD and 99mTc-HMPAO.

  9. Investigating the Role of Global Histogram Equalization Technique for 99mTechnetium-Methylene diphosphonate Bone Scan Image Enhancement.

    Science.gov (United States)

    Pandey, Anil Kumar; Sharma, Param Dev; Dheer, Pankaj; Parida, Girish Kumar; Goyal, Harish; Patel, Chetan; Bal, Chandrashekhar; Kumar, Rakesh

    2017-01-01

    99m Technetium-methylene diphosphonate ( 99m Tc-MDP) bone scan images have limited number of counts per pixel, and hence, they have inferior image quality compared to X-rays. Theoretically, global histogram equalization (GHE) technique can improve the contrast of a given image though practical benefits of doing so have only limited acceptance. In this study, we have investigated the effect of GHE technique for 99m Tc-MDP-bone scan images. A set of 89 low contrast 99m Tc-MDP whole-body bone scan images were included in this study. These images were acquired with parallel hole collimation on Symbia E gamma camera. The images were then processed with histogram equalization technique. The image quality of input and processed images were reviewed by two nuclear medicine physicians on a 5-point scale where score of 1 is for very poor and 5 is for the best image quality. A statistical test was applied to find the significance of difference between the mean scores assigned to input and processed images. This technique improves the contrast of the images; however, oversaturation was noticed in the processed images. Student's t -test was applied, and a statistically significant difference in the input and processed image quality was found at P histogram equalization technique in combination with some other postprocessing technique is useful.

  10. Clearance of technetium-99m-DTPA and HRCT findings in the evaluation of patients with Idiopathic Pulmonary Fibrosis

    Directory of Open Access Journals (Sweden)

    Karkavitsas Nikolaos

    2006-02-01

    Full Text Available Abstract Background Clearance of inhaled technetium-labeled diethylenetriamine pentaacetate (99mTc-DTPA is a marker of epithelial damage and an index of lung epithelial permeability. The aim of this study was to investigate the role of 99mTc-DTPA scan in patients with Idiopathic Pulmonary Fibrosis (IPF. Our hypothesis is that the rate of pulmonary 99mTc-DTPA clearance could be associated with extent of High Resolution Computed Tomography (HRCT abnormalities, cell differential of bronchoalveolar lavage fluid (BALF and pulmonary function tests (PFTs in patients with IPF. Methods We studied prospectively 18 patients (14 male, 4 female of median age 67yr (range 55–81 with histologically proven IPF. HRCT scoring included the mean values of extent of disease. Mean values of these percentages represented the Total Interstitial Disease Score (TID. DTPA clearance was analyzed according to a dynamic study using a Venticis II radioaerosol delivery system. Results The mean (SD TID score was 36 ± 12%, 3 patients had mild, 11 moderate and 4 severe TID. Abnormal DTPA clearance half-time (t1/2 Conclusion Our data suggest that 99mTc-DTPA lung scan is not well associated with HRCT abnormalities, PFTs, and BALF cellularity in patients with IPF. Further studies in large scale of patients are needed to define the role of this technique in pulmonary fibrosis.

  11. Contribution of the Technetium-99m-sestamibi (MIBI) scintigraphy in primary hyperparathyroidism to determination of parathyroidectomy

    International Nuclear Information System (INIS)

    Nishida, Takuro; Hayakawa, Katsumi; Nishimura, Kazumasa; Kawakami, Satoshi; Sakamoto, Makoto; Koh, Toshikiyo; Hida, Shuichi

    1999-01-01

    We reviewed retrospectively the 12 patients who underwent parathyroidectomy because of hyperparathyroidism and judged to what degree the Technetium-99m-sestamibi (MIBI) scintigraphy contributed to determination of parathyroidectomy. From the view point that weather parathyroidectomy could be decided without the MIBI scintigraphy, we classified the cases into three groups; great, fair, and poor contribution. We judged 4 cases as great contribution, 5 cases as fair contribution and 3 cases as poor contribution. We concluded that if the MIBI scintigraphy is positive in patients with primary hyperparathyroidism, parathyroidectomy is strongly recommended, because of its high sensitivity and accuracy for detection of parathyroid adenomas and because there were no false-positive cases with the MIBI scintigraphy. (author)

  12. Evaluation of the effect of an extract of sabugueiro (Sambucus australis) on the labeling of blood constituents with technetium-99m

    International Nuclear Information System (INIS)

    Ribeiro, Camila Godinho; Rebello, Bernardo Machado; Neves, Rosane de Figueiredo; Santos-Filho, Sebastiao David; Fonseca, Adenilson de Souza da; Medeiros, Aldo da Cunha; Bernardo-Filho, Mario; Catanho, Maria Teresa Jansem de Almeida

    2007-01-01

    Sambucus australis (sabugueiro) has been used to treat inflammatory and rheumatologic disorders. Blood constituents labeled with technetium-99m (99mTc) have been used in nuclear medicine to obtain diagnostic images. The aim of this work was to evaluate the effect of a sabugueiro extract on the labeling of blood cells with 99mTc. Blood samples from Wistar rats were incubated with sabugueiro extract and the radiolabeling assay of blood constituents was carried out. After centrifugation, samples of plasma and blood cells were separated. Aliquots of plasma and blood cells were precipitated with trichloroacetic acid and centrifuged to isolate soluble and insoluble fractions. The radioactivity in each fraction was counted and the percentage of activity (%ATI) was determined. Incubation with sabugueiro extract altered significantly (p<0.05) the %ATI incorporated to the blood constituents. These results could be explained due the presence of chemical substances in the sabugueiro extract that present redox and/or chelating action altering the labeling of the blood constituents with 99mTc. (author)

  13. Increased bone marrow blood flow in sickle cell anemia demonstrated by thallium-201 and Tc-99m human albumin microspheres

    International Nuclear Information System (INIS)

    Thrall, J.H.; Rucknagel, D.L.

    1978-01-01

    Lower extremity vascularity in nine patients with sickle cell anemia was studied by intra-arterial /sup 99m/Tc human albumin microspheres or intravenous thallium-201. In eight patients, the normal pattern of greater muscle than bone activity was reversed with marked tracer localization in skeletal parts usually not visualized. In four cases, there were distinct focal abnormalities in the femurs and tibias which correlated with defects on /sup 99m/Tc sulfur colloid marrow scans. TC-99m pyrophosphate bone scans demonstrated normal uptake in the same areas. The scintigraphic findings indicate a markedly increased relative bone marrow blood flow

  14. {sup 99} {sup m}Tc-sulphur-colloid and heat-denatured {sup 99} {sup m}Tc-labelled red cell scans demonstrating a giant intrapelvic spleen in a girl after splenectomy

    Energy Technology Data Exchange (ETDEWEB)

    Kao, P.F. [Dept. of Nuclear Medicine, Chang Gung Memorial Hospital and Chang Gung University School of Medicine, Tauyuan, Taiwan (Taiwan); Dept. of Nuclear Medicine, Chang Gung Memorial Hospital, Taipei, Taiwan (Taiwan); Tzen, K.Y.; Tsai, M.F. [Dept. of Nuclear Medicine, Chang Gung Memorial Hospital and Chang Gung University School of Medicine, Tauyuan, Taiwan (Taiwan); Lin, J.N. [Dept. of Paediatric Surgery, Chang Gung Childrens Hospital and Chang Gung University School of Medicine, Tauyuan, Taiwan (Taiwan)

    2001-04-01

    A 17 x 12 x 5-cm giant intrapelvic mass in a 14-year-old girl is reported. This mass developed 6 years after a splenectomy for splenic torsion. The heat-denatured {sup 99} {sup m}Tc-labelled red cell scan and {sup 99} {sup m}Tc- sulphur-colloid scan confirmed the specific red cell sequestration function and reticuloendothelial activity in the giant intrapelvic spleen. The size and development of the giant intrapelvic spleen are unusual. The usefulness of functional images to diagnosis the nature of the intrapelvic mass is well demonstrated. (orig.)

  15. Doses to nurses by the technetium-99m, in private and public sector

    International Nuclear Information System (INIS)

    Bied, J.Ch.; Philippon, B.

    1999-01-01

    The global body dose due to the technetium is 1.2 and 1.9 mSv for the two nurses of the private sector. In the public sector, the level reached by the personnel is 0.75 mSv for the global body dose, and the only technetium (global body dose 1.4 and 2.1 mSv for the private sector, 0.95 for the public sector and for the whole of radiations measured by the O.P.R.I. film dosemeter. The doses received at the fingers level present higher levels in the private sector. But these values, 15.2 and 10.7 mSv by month, that is to say 180 mSv by year are the 2/5 of the maximum permissible value. The two persons of the private sector received whole body doses, higher that the doses of the public sector. These doses are about 1.2 to 1.9 these ones received in the public sector. (N.C.)

  16. An extract of a formula used in the traditional chinese medicine (Buzhong Yi Qi Wan) alters the labeling of blood constituents with technetium-99m

    International Nuclear Information System (INIS)

    Giani, Tania Santos; Paoli, Severo de; Brandao-Neto, Jose; Medeiros, Aldo da Cunha; Presta, Giuseppe Antonio; Maiworm, Adalgisa Ieda; Santos Filho, Sebastiao David; Fonseca, Adenilson de Souza da; Bernardo-Filho, Mario

    2007-01-01

    Buzhong Yi Qi Wan (Buzhong) is a medicinal herb widely used in Traditional Chinese Medicine to treat the digestive and circulatory systems. Red blood cell and plasma proteins labeled with technetium-99m ( 99m Tc) are used in nuclear medicine. The aim of this work was to investigate the effects of an aqueous Buzhong extract on the labeling of blood constituents with 99m Tc. Heparinized blood (Wistar rats) was incubated in vitro with different Buzhong extract concentrations and 99m Tc-labeling was performed. Plasma (P) and blood cells (BC) were separated and soluble (SF-P, SF-BC) and insoluble (IF-P, IF-BC) fractions were isolated. The radioactivity on blood constituents was determined and the percentage of incorporated radioactivity (%ATI) was calculated. Buzhong extract at the highest concentrations used altered significantly (p 99 mTc. (author)

  17. Autoradiography and density gradient separation of technetium-99m-Exametazime (HMPAO) labelled leucocytes reveals selectivity for eosinophils

    Energy Technology Data Exchange (ETDEWEB)

    Puncher, M.R.B. [Biological Lab., Univ. of Kent, Canterbury (United Kingdom); Blower, P.J. [Nuclear Medicine Dept., Kent and Canterbury Hospital (United Kingdom)

    1994-11-01

    Technetium-99m-Exametazime (HMPAO) is widely used for radiolabelling leucocytes for localization of infection. The subcellular distribution of radionuclide in the labelled cells and the distribution of radioactivity among the leucocyte population are incompletely understood. Frozen section autoradiography was used to determine quantitatively the distribution of {sup 99m}Tc in leucocytes labelled with {sup 99m}Tc-Exametazime. Sections of rapidly frozen suspensions of labelled leucocytes in plasma were autoradiographed on Ilford K2 emulsion and stained with haematoxylin and eosin. Neutrophils, eosinophils and mononuclear cells were separated by Percoll density gradient centrifugation. Cell nuclei were isolated by a rapid cell-breakage and fractionation method. In a typical experiment mean grain densities [grains/100 {mu}m{sup 2} (ESD)] over cells were: eosinophils 31.2 (18.4), neutrophils 3.5 (3.5), mononuclear cells 4.2 (5.1). Mean grain numbers per cell (ESD) were: eosinophils 13 (6.8), neutrophils 1.3 (1.3), mononuclear cells 1.1 (1.3). These findings were confirmed by separation of labelled leucocytes on discontinuous density gradients. In four separation experiments, the mean activity-per-cell ratio for eosinophils to neutrophils was 10.1 (4.8):1, and for eosinophils to mononuclear cells, 14.1 (6.7):1. The subcellular distribution of the label was investigated using image analysis of autoradiographs and cell fractionation. This revealed no selectivity for nuclear or extranuclear compartments. It may be concluded that {sup 99m}Tc-Exametazime has strong selectivity for eosinophils over other leucocytes but no selectivity for nuclear/cytoplasmic compartments. (orig.)

  18. Technetium-99m sestamibi leg scintigraphy for non-invasive assessment of propionyl-l-carnitine induced changes in skeletal muscle metabolism

    International Nuclear Information System (INIS)

    Cittanti, C.; Colamussi, P.; Giganti, M.; Orlandi, C.; Uccelli, L.; Manfrini, S.; Azzena, G.; Piffanelli, A.

    1997-01-01

    Carnitine derivatives, such as propionyl-l-carnitine (PLC), have been shown to improve walking distance in patients with obstructive peripheral artery disease (PAOD). The aim of this study was to ascertain whether technetium-99m sestamibi leg scintigraphy may be a useful tool in the evaluation of changes in skeletal muscle metabolism induced by chronic therapy with PLC. Twenty patients with clinical and instrumental evidence of PAOD were randomly assigned to a 3-month period of therapy with either PLC or placebo. Rest 99m Tc-sestamibi leg scintigraphy and echo-Doppler sonography were performed on all subjects immediately before and upon completion of the treatment period. At the end of the protocol the following results were observed in patients who underwent PLC administration: (a) a significant increase in both thigh and calf 99m Tc-sestamibi uptake, in comparison with baseline values (P 99m Tc-sestamibi was demonstrated without any apparent change in regional blood flow. This fact, if proven in further studies, may suggest a role for this tracer as a non-invasive probe of tissue bioenergetics. (orig.). With 4 figs., 4 tabs

  19. Imaging of intraperitoneal tumors with technetium-99m GSA

    International Nuclear Information System (INIS)

    Yao, Zhengsheng; Zhang, Meili; Sakahara, Harumi; Saga, Tsuneo; Nakamoto, Yuji; Sato, Noriko; Zhao, Songji; Konishi, Junji; Arano, Yasushi

    1998-01-01

    99m Tc labeled galactosyl serum albumin (GSA) has been used clinically as a receptor-binding agent for the assessment of liver function. The aim of this study was to investigate the usefulness of 99m Tc-GSA in intraperitoneal (i.p.) tumor imaging. A tumor model was established by i.p. inoculating nude mice with human ovarian cancer cell SHIN-3, or colon cancer cell LS180. Radiolabels were i.p. injected into the tumor-bearing mice and the biodistribution of radioactivity was examined. After administration, 99m Tc-GSA rapidly accumulated in the tumor. The tumor uptake was 5.82-8.46% ID/g from 30 min to 6 h after the injection. Radioactivity in the blood was very low, less than 0.3% ID/g, resulting in high tumor-to-blood ratio. Tumors could be clearly seen by scintigraphic imaging. Accumulation of i.p.-injected 99m Tc labeled human serum albumin (HSA) in i.p. tumors was similar to that of 99m Tc-GSA, but radioactivity of 99m Tc-HSA in the circulation was high, resulting in a significantly lower tumor-to-blood ratio. In conclusion, 99m Tc-GSA, when i.p. injected, accumulated in i.p. tumors and cleared from circulation rapidly, which would make it useful for the imaging of i.p. tumors. (author)

  20. Clinical usefulness of subtraction scintigraphy of the liver with Ga-67-citrate and Tc-99m-colloid

    International Nuclear Information System (INIS)

    Oyamada, H.; Terui, S.; Nagaiwa, K.; Kawai, H.; Fukukita, H.

    1983-01-01

    Subtraction scintigraphy of the liver with Ga-67-citrate and Tc-99m-colloid was performed for the radionuclide image diagnosis of intrahepatic masses, especially hepatoma. In this method the Tc-99m image was subtracted from the Ga-67 image. After normalizing both images, 4 different factors (0.6, 0.8, 1.0, and 1.2) were applied to the Tc-99m image before the subtraction. Finally, 4 subtraction images with different contrasts were obtained in one X-ray film. This method was found to be very useful in the assessment of intrahepatic focal accumulation of Ga-67, especially in cases with hepatoma, because it eliminated the uncertainty in the former method in which only visual judgment was done

  1. Technetium-99m mercaptoacetyltriglycine clearance values in children with minimal renal disease: can a normal range be determined?

    International Nuclear Information System (INIS)

    Meyer, G.; Hahn, K.; Piepsz, A.; Kolinska, J.; Lepej, J.; Sixt, R.

    1998-01-01

    Use of technetium-99m labelled mercaptoacetyltriglycine ( 99m Tc-MAG3) simplifies and improves the quantification of renal clearance in children by virtue of its permanent availability, good imaging properties and low radiation exposure. Due to the lack of reference values for 99m Tc-MAG3 clearance in children, the Paediatric Task Group of the EANM initiated a multicentre study to evaluate 99m Tc-MAG3 clearance values in children with minimal renal disease. One hundred and twenty-five children aged between 12 months and 17 years, classified as renally healthy using defined diagnostic criteria, were included in the study. 99m Tc-MAG3 clearance was calculated using an algorithm on the basis of a single blood sample taken at any time between 30 and 40 min after tracer injection. In addition, the absolute 99m -Tc-MAG3 clearance values were normalized to body surface area. For further evaluation the children were classified into several groups according to age. There was a continuous increase in non-corrected 99m Tc-MAG3 clearance values from the age of 1 year up to the age of 17 years (mean value 8 years: 208±66 ml/min). Normal clearance values for adults were achieved by the age of 8 years. Analysis of the relationship between non-corrected clearance and age yielded a correlation coefficient of r=0.7. When these absolute clearance values were normalized to body surface area, we found nearly constant clearance values for all age groups, with a mean clearance value of 315±114 ml/min x 1.73 m 2 . The correlation coefficient for the relationship between normalized clearance and age was r=0.28. In conclusion, the clearance of 99m Tc-MAG3 increases continuously throughout childhood into adolescence due to the maturation and growth of the kidney. After normalization of the absolute clearance to body surface area, no correlation between clearance and age could be proven. (orig.)

  2. Usefulness of technetium-99m tetrofosmin single-photon emission computed tomography for short-term risk stratification in patients with acute chest pain in the emergency room

    International Nuclear Information System (INIS)

    Kawahito, Michitomo; Kondo, Makoto; Abe, Yoshiteru

    2003-01-01

    High-risk patients with acute coronary syndrome are difficult to distinguish from low-risk patients with chest pain in the emergency room. Technetium-99 m ( 99m Tc) tetrofosmin single-photon emission computed tomography (SPECT) was investigated to exclude high-risk patients with chest pain in the emergency room. 99m Tc-tetrofosmin SPECT was evaluated using a four-point scoring system in 228 patients (144 men, 84 women, mean age 68±12 years) with chest pain. Negative was defined as the myocardial segments with a defect score (DS) of 99m Tc-tetrofosmin; no significance (NS)), 84.9% (NS) and 60.4% (p 99m Tc-tetrofosmin SPECT is a useful method to exclude high-risk patients among patients with chest pain in the emergency room. (author)

  3. Solid phase labelling of technetium-99m glutamic acid: Radiopharmacological studies

    International Nuclear Information System (INIS)

    Campos, E.; Kremer, C.; Leon, A.; Martinez, G.; Gaudiano, J.

    1989-01-01

    Amino acids labelled with 11 C and 13 N are used in localizing tumours, and in scintiscanning pancreas and myocardium. The behaviour of glutamic acid labelled with 99m Tc in healthy and tumour bearing animals is described. Under optimal conditions, a labelling efficiency of 26% is obtained, with a radiochemical purity of 96% and no detectable colloids. Zinc concentrations in the final preparation are well below those at which chemical toxicity becomes apparent. Previous studies suggest the structure as that of an oxotechnetium complex (TcO 2 (glu 2 )) 4- (pH 6). Biodistribution studies have been performed in normal mice. Paper electrophoresis shows that the complex is excreted unchanged via the kidneys. In animals with adenocarcinoma at various stages of differentiation, tumour to blood ratios of between 0.4 and 2.0 are observed. Blood clearance and renal excretion in human subjects are reported and uptake in human breast carcinoma is demonstrated. (author)

  4. Measurement of technetium-99 in Marshall Islands soil samples by ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Tagami, K. E-mail: k_tagami@nirs.go.jp; Uchida, S.; Hamilton, T.; Robison, W

    2000-07-15

    Extraction techniques for recovery of technetium-99 ({sup 99}Tc) for Inductively Coupled Plasma Mass Spectrometry (ICP-MS) measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (M1) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for {sup 99}Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the {sup 99}Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The {sup 99}Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq g{sup -1} dry weight (dw). The limit of detection for {sup 99}Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq g{sup -1} dw under standard operating conditions.

  5. Scintigraphy in the followup of pediatric splenic trauma treated without surgery

    International Nuclear Information System (INIS)

    Fischer, K.C.; Eraklis, A.; Rossello, P.; Treves, S.

    1977-01-01

    Twenty patients with blunt abdominal trauma were diagnosed as having splenic rupture by Tc-99m sulfur colloid scintigraphy. Because of the increased risk of infection in children following splenectomy, surgery was not performed and scintigraphic followup of the injured spleens was carried out. Thirteen patients were scanned at least 2 mo after trauma and the longest followup was 1 yr. Only three spleens showed ''scintigraphic healing.'' The remaining ten showed smaller defects, but in two patients the size of the defect did not change after the 2-mo scan. In no case did the scan defect enlarge. Technetium-99m sulfur colloid scintigraphy offers a convenient and sensitive method of following trauma cases if no surgery is performed. Scintigraphic defects can persist for long periods of time while the patient is asymptomatic

  6. Comparison of uteroplacental blood flow in normal and pre-eclamptic patients measurement with technetium-99m and a computer-linked gamma camera

    International Nuclear Information System (INIS)

    Cho, S.H.; Moon, H.; Kim, D.S.; Cho, S.S.

    1985-01-01

    Uteroplacental blood flow studies in preeclampsia are of special interest since the vascular changes reported in this disease might constitute a structural basis for a reduction of blood flow. Evidence has also been given for a decreased uteroplacental blood flow in preeclampsia. Among the various methods to estimate the maternal placental blood flow, the one most frequently reported in the literature during the last years has been the time activity analysis of short lived radiotracer such as technetium-99m or indium-113m injected intravenously. Only few studies with the above mentioned technique comparing normal and preeclampsia cases have been undertaken. In clinical practice we frequently experience difficuly in finding the optimal time to get the delivery in preeclampsia patients. The aim of this study was first to measure uteroplacental blood flow in preeclamptic pregnancies using a computer-linked gamma camera method for the time-activity analysis of technetium-99m and second to discuss the possibility of clinical application of these measurements for determination of fetal well-being and the timing of the delivery in these patients. Uteroplacental blood flow was measured from 13 preeclamptic patients and 19 pregnancies without any complication after 35 completed weeks of gestation from Jan. 1983 to Sep. 1983 at Obstetrics department of Hanyang University Hospital. (Author)

  7. Comparison of uteroplacental blood flow in normal and pre-eclamptic patients measurement with technetium-99m and a computer-linked gamma camera

    Energy Technology Data Exchange (ETDEWEB)

    Cho, S.H.; Moon, H.; Kim, D.S.; Cho, S.S.

    1985-05-01

    Uteroplacental blood flow studies in preeclampsia are of special interest since the vascular changes reported in this disease might constitute a structural basis for a reduction of blood flow. Evidence has also been given for a decreased uteroplacental blood flow in preeclampsia. Among the various methods to estimate the maternal placental blood flow, the one most frequently reported in the literature during the last years has been the time activity analysis of short lived radiotracer such as technetium-99m or indium-113m injected intravenously. Only few studies with the above mentioned technique comparing normal and preeclampsia cases have been undertaken. In clinical practice we frequently experience difficuly in finding the optimal time to get the delivery in preeclampsia patients. The aim of this study was first to measure uteroplacental blood flow in preeclamptic pregnancies using a computer-linked gamma camera method for the time-activity analysis of technetium-99m and second to discuss the possibility of clinical application of these measurements for determination of fetal well-being and the timing of the delivery in these patients. Uteroplacental blood flow was measured from 13 preeclamptic patients and 19 pregnancies without any complication after 35 completed weeks of gestation from Jan. 1983 to Sep. 1983 at Obstetrics department of Hanyang University Hospital. (Author).

  8. 99mTc-tetrapeptides: radiolabelling and biodistribution in rats

    International Nuclear Information System (INIS)

    Laznickova, A.; Laznicek, M.; Trejtnar, F.; Mather, S.J.

    1998-01-01

    Preparation of 99m Tc-labelled tetrapeptides, namely acetyl-Gly-Gly-Cys-Gly (I), acetyl-Ser-Ser-Cys-Gly (II) and acetyl-Gly-Gly-Cys-Lys (III), analysis of their radiochemical purity and biodistribution were investigated in rats. The aim was to determine the relationship between structure and biological behaviour of 99m Tc-labelled peptides which are formed by amino-acid sequences capable of chelating technetium useful as universal chelators in ''hybrid'' peptides composed of receptor-specific part and the part chelating technetium. For labelling with 99m Tc, a conventional transchelation from 99m Tc-gluconate was used and radiolabelled peptides were purified by filtration on Whatman microfilters 12 kD. Radiochemical purity was higher than 98%. Biodistribution studies in rats showed that all agents are rapidly cleared from the body mostly via urine, but some part of administered radioactivity also in the faces was found. The later route of elimination way increased in the order III 99m Tc-MAG3. The results obtained will assist with design of optimal biocompatible tetrapeptides as chelators for formation of hybrid receptor-specific peptides. (author)

  9. Pharmacokinetics of labelled compounds with technetium-99m and samarium-153

    International Nuclear Information System (INIS)

    Borda O, L.B.; Torres L, M.N.

    1997-01-01

    The purpose of this investigation was to establish the different pharmacokinetics parameters of the main radiopharmaceuticals labeled with technetium-99m and samarium-153. These parameters could be subsequently used as reference to compare other products with the same use. Mathematical models and a computerized pharmacokinetic program were used to this purpose. A biodistribution study in quadruplicate and/or quintuplicate was conducted for each radiopharmaceutical, data was was obtained in injection dose percentages. The biodistribution study involved the injection of a predetermined dose of the radiopharmaceutical into animals (rats or mice), which were subsequently put away at different time intervals, removing the relevant organs. Activity in each organ was read by means of a well-type NaI scintillation counter, data obtained in activity counts was transformed into injection dose percentages. Based on these percentages, the mathematical model was constructed and the pharmacokinetic parameters were obtained using the computerized program Expo 2 v. 1, which is written in C language and works in windows. Analyzing the results obtained, we can conclude that the use of the Expo 2 v. 1 program for a bi compartmental analysis allowed us to obtain reliable pharmacokinetic parameters which describe what happens in the organism when the radiopharmaceutical passes from the central compartment to the peripheral one and vice versa

  10. Technetium-99m-hexakis-2-methoxyisobutylisonitrile scintigraphy and multidrug resistance-related protein expression in human primary lung cancer

    International Nuclear Information System (INIS)

    Duan Xiaoyi; Wang Jiansheng; Liu Min; Guo Youmin

    2008-01-01

    The occurrence of multidrug resistance (MDR) is a major cause of resistance to chemotherapeutic agents in patients with lung cancer, in part owing to the overexpression of MDR-related proteins. Technetium-99m-hexakis-2-methoxyisobutylisonitrile ( 99m Tc-MIBI) has been shown to be a substrate for some MDR-related proteins. The aim of this study is to evaluate the role of 99m Tc-MIBI scintigraphy for functional imaging of MDR-related protein phenotypes. To determine the correlation between 99m Tc-MIBI scintigraphy and the expression level of P-glycoprotein (Pgp), multidrug-resistance protein (MRP), and glutathione-S-transferase Pi (GSTπ), 26 patients (17 men and 9 women, median age 57.5 years) with primary lung cancer were investigated. Following intravenous administration of 925 MBq 99m Tc-MIBI, single-photon emission computed tomography (SPECT) and computed tomography (CT) were performed at 15 min and 2 h. On the basis of the fused images, tumor to background (T/B) ratio of both early and delayed images, and washout rate (WR%) of 99m Tc-MIBI were calculated. The immunohistochemical staining of Pgp, MRP, and GSTπ was performed, and the expression level was semiquantitated using a pathoimage analysis system. The imaging results were compared with the status of Pgp, MRP, and GSTπ expression. The WR% of 99m Tc-MIBI showed a significant positive correlation with Pgp expression (r=0.560, P=0.003), as no correlation was observed between WR% and MRP or GSTπ (r=0.354, P=0.076; r=0.324, P=0.106). Neither early T/B nor delayed T/B correlated with the expression level of Pgp, MRP, and GSTπ. WR%, Pgp, and GSTπ expression showed significant differences between squamous cell carcinoma (group A) and adenocarcinoma (group B). There was no significant difference among Pgp, MRP, and GSTπ expression levels in any cases (P>0.05). Our data confirmed that 99m Tc-MIBI scintigraphy is useful for determining the MDR caused by Pgp in patients with primary lung cancer. (author)

  11. Scintigraphic study of gastric emptying with colloidal tin

    International Nuclear Information System (INIS)

    Rodríguez Paleo, Lester; Nuez Vilar, Maricela; Machado Lois, Marisel; López González, María Karla; Torres Leyva, Oscar; Izquierdo Izquierdo, Yimel; García González, Idelsy; Conesa Gonzalez, Ana Ibis

    2016-01-01

    Gastroparesis is defined as a delay in gastric emptying in the absence of mechanical obstruction, associated with symptoms such as nausea and / or vomiting, feeling of postprandial gastric fullness, early satiety or epigastric pain for more than 3 months. The gold standard in the diagnosis of delayed gastric emptying scintigraphy is gastric emptying and radiopharmaceutical has been used more 99m Tc-sulfur colloid not available in the country. In order to evaluate the usefulness of colloidal tin in the scintigraphic gastric emptying study, a descriptive study was conducted in 64 patients over 18 years using as radiopharmaceutical 99m Tc-Sn colloid. 31% of patients had symptoms. The emptying time was normal in 50 cases and the association of gastroparesis symptoms was observed in 20 (15 diabetic and 5 non-diabetic), 9 patients had a delayed emptying, but reported no symptoms. Gastroparesis was more frequent in women than in men (35% versus 21%). 21% of patients had a moderate delayed gastric emptying. Conclusions: The results obtained with 99m Tc-Sn colloid are comparable to those reported by other authors using 99m Tc-SC in the scintigraphic assessment of gastric emptying. (author)

  12. A comparative technetium 99m hexamethylpropylene amine oxime SPET study in different types of dementia

    Energy Technology Data Exchange (ETDEWEB)

    Habert, M.O.; Piketty, M.L.; Askienazy, S. (Centre Hospitalier Sainte-Anne, 75 - Paris (France). Dept. de Medecine Nucleaire); Spampinato, U.; Mas, J.L.; Recondo, J. de; Rondot, P. (Centre Hospitalier Sainte-Anne, 75 - Paris (France). Dept. de Neurologie); Bourdel, M.C. (Centre Hospitalier Sainte-Anne, 75 - Paris (France). Dept. de Psychiatrie)

    1991-01-01

    Regional cerebral perfusion was evaluated by single photon emission tomography (SPET) using technetium 99m hexamethylpropylene amine oxime ({sup 99m}Tc-HMPAO) as a tracer, in 13 control subjects and 44 age-matched patients suffering from dementia of the Alzheimer's type (DAT, n=19) presumed Pick's disease (n=5), idiopathic Parkinson's disease with dementia (DPD, n=15) and progressive supranuclear palsy (PSP, n=5), HMPAO uptake was measured in the superior frontal, inferior frontal, parietal, temporal and occipital cortices, and the perfusion values were expressed as cortical/cerebellar activity ratios. As compared with controls, tracer uptake ratios in the DAT group were signficantly reduced over all cortical regions, with the largest defects in the parieto-temporal and superior frontal cortices. A marked hypoperfusion affecting the superior and inferior frontal cortices was found in Pick's diesease, whereas a mild but significant hypoperfusion was observed only in the superior frontal cortex of patients with PSP. In the DPD group, HMPAO uptake was significantly reduced in the parietal, temporal and occipital cortices, but not in the frontal cortex. These results show that DAT and DPD share the opposite anteroposterior HMPAO uptake defect as compared with the Pick's and PSP groups. (orig.).

  13. High power targets for cyclotron production of 99mTc‡

    OpenAIRE

    Zeisler, S. K.; Hanemaayer, V.; Buckley, K. R.; Hook, B. K.; MeDiarmid, S.; Klug, J.; Corsaut, J.; Kovacs, M.; Cockburn, N.; Exonomou, C.; Harper, R.; Valliant, J. F.; Ruth, T. J.; Schaffer, P.

    2015-01-01

    Introduction Technetium-99m, supplied in the form of 99Mo/99mTc generators, is the most widely used radioisotope for nuclear medical imaging. The parent isotope 99Mo is currently produced in nuclear reactors. Recent disruptions in the 99Mo supply chain [1] prompted the development of methods for the direct accelerator-based production of 99mTc. Our approach involves the 100Mo(p,2n)99mTc reaction on isotopically enriched molybdenum using small medical cyclotrons (Ep ≤ 20 MeV), which is ...

  14. Influence of some drugs, used in coronary artery disease on in vitro labelling red blood cells with technetium 99mTc

    International Nuclear Information System (INIS)

    Poniatowicz-Frasunek, E.

    1997-01-01

    In some patients investigated by radionuclide ventriculography poor labeling efficiency of red blood cells with technetium 99m Tc is observed. Among possible mechanisms responsible for this phenomenon, the pharmacological treatment applied to the patients should be taken into consideration. The aim of the study was to define the effect of selected drugs used in CAD on technetium binding efficiency by erythrocytes in vitro. Blood samples were obtained from 40 normal individuals receiving no medication. The effect of the following drugs were examined: Aerosonit, Isoptin, Bemecor, Dopegyt, Enarenal, Binazin, Furosemid, Aspirin, Vitamin E and Propranolol. Only Enarenal and Vitamin E proved to have no effect on technetium binding efficiency. The most expressed reduction was observed in experiments with Aerosonit, Furosemid and Propranolol and the smallest changes were found in blood samples with Bemecor, Binazin and Aspirin. The results of the study suggest that pharmacological treatment may influence the quality of scintigraphic images obtained with radioisotope ventriculography. For that reason the medicines applied to the patients should be as much as possible reduced or withdrawn for at least several days before examination. (author)

  15. Technetium-99m sestamibi single-photon emission tomography detects subclinical myocardial perfusion abnormalities in patients with systemic lupus erythematosus

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, O. [Nuclear Medicine, University of l`Aquila (Italy); Lagana, B.; Gentile, R.; Tubani, L.; Baratta, L. [Department of Clinical Medicine, University ``La Sapienza``, Rome (Italy); Danieli, R.; Scopinaro, F. [Section of Nuclear Medicine, Department of Experimental Medicine and Pathology, University ``La Sapienza``, Rome (Italy)

    1999-07-01

    In patients with systemic lupus erythematosus, involvement of the cardiovascular system is the third leading cause of death. However, although autopsy studies have demonstrated a high incidence of abnormalities in both the myocardium and coronary vessels, clinical manifestations have been reported in only a small percentage of cases. The aim of this study was to evaluate myocardial perfusion in asymptomatic lupus patients using technetium-99m sestamibi single-photon emission tomography (SPET). Twenty-eight patients without overt cardiac involvement and risk factors were studied with {sup 99m}Tc-sestamibi SPET at rest and after dipyridamole infusion. Perfusion abnormalities were detected in 18 cases: six had persistent defects, three had reversible defects, seven had both persistent and reversible defects, and two showed rest defects which normalized on dipyridamole images (``reverse redistribution pattern``). Coronary angiography was performed in eight patients with positive {sup 99m}Tc-sestamibi SPET, and showed normal epicardial vessels in all the cases. These results indicate that {sup 99m}Tc-sestamibi SPET reveals a high prevalence (18 out of 28 patients in this study, i.e. 64%) of myocardial perfusion abnormalities in asymptomatic lupus patients, probably due to the primary immunological damage of this autoimmune disease. In conclusion, rest/dipyridamole {sup 99m}Tc-sestamibi SPET can be a useful non-invasive method to identify subclinical myocardial involvement in systemic lupus erythematosus, and patients potentially at risk of later cardiac events. (orig.) With 2 figs., 2 tabs., 21 refs.

  16. Technetium-99m sestamibi single-photon emission tomography detects subclinical myocardial perfusion abnormalities in patients with systemic lupus erythematosus

    International Nuclear Information System (INIS)

    Schillaci, O.; Lagana, B.; Gentile, R.; Tubani, L.; Baratta, L.; Danieli, R.; Scopinaro, F.

    1999-01-01

    In patients with systemic lupus erythematosus, involvement of the cardiovascular system is the third leading cause of death. However, although autopsy studies have demonstrated a high incidence of abnormalities in both the myocardium and coronary vessels, clinical manifestations have been reported in only a small percentage of cases. The aim of this study was to evaluate myocardial perfusion in asymptomatic lupus patients using technetium-99m sestamibi single-photon emission tomography (SPET). Twenty-eight patients without overt cardiac involvement and risk factors were studied with 99m Tc-sestamibi SPET at rest and after dipyridamole infusion. Perfusion abnormalities were detected in 18 cases: six had persistent defects, three had reversible defects, seven had both persistent and reversible defects, and two showed rest defects which normalized on dipyridamole images (''reverse redistribution pattern''). Coronary angiography was performed in eight patients with positive 99m Tc-sestamibi SPET, and showed normal epicardial vessels in all the cases. These results indicate that 99m Tc-sestamibi SPET reveals a high prevalence (18 out of 28 patients in this study, i.e. 64%) of myocardial perfusion abnormalities in asymptomatic lupus patients, probably due to the primary immunological damage of this autoimmune disease. In conclusion, rest/dipyridamole 99m Tc-sestamibi SPET can be a useful non-invasive method to identify subclinical myocardial involvement in systemic lupus erythematosus, and patients potentially at risk of later cardiac events. (orig.)

  17. Site-specific conjugation and labelling of prostate antibody 7E11C5.3 (CYT-351) with technetium-99m

    International Nuclear Information System (INIS)

    Stalteri, M.A.; Mather, S.J.; Belinka, B.A.; Coughlin, D.J.; Chengazi, V.U.; Britton, K.E.

    1997-01-01

    Attachment of chelating agents to the sugar residues of antibodies for subsequent radiolabelling is an attractive approach since it may have less effect on the immunoreactivity than attachment through lysine residues, which are distributed throughout the antibody and may be present near the antigen binding site. We have attached a new hydrazide-linked chelator CYT-395 (Cytogen Corp., Princeton, N.J.) to the sugar residues of the anti-prostate monoclonal antibody 7E11C5.3 and optimised the conditions for labelling the conjugate with technetium-99m in order to compare the conjugate to 7E11C5.3 antibody labelled directly with technetium using a mercaptoethanol reduction technique. Labelling yields of 70%-90% were obtained at specific activities up to 2000 MBq/mg antibody. The stability of the technetium-labelled conjugate in plasma or to a challenge with 0.1 or 1.0 mM cysteine was similar to that of direct-labelled antibody. In nine patients with prostate cancer, the plasma clearance of the labelled conjugate followed a two-compartment model, with an average β-phase half-life of 31.4±3.9 h. The average urinary clearance at 24 h was 15.3±5.0% of the injected dose. In this group of patients there was no significant difference between the blood and urine clearance of the labelled conjugate, and the clearances of the direct-labelled antibody. (orig.). With 5 figs

  18. Consequences of the magnetic field, sonic and radiofrequency waves and intense pulsed light on the labeling of blood constituents with technetium-99m

    International Nuclear Information System (INIS)

    Meyer, Patricia Froes; Costa, Iris do Ceu Clara; Brandao-Neto, Jose; Medeiros, Aldo da Cunha; Bonelli, Ludmila

    2007-01-01

    Sources of magnetic field, radiofrequency and audible sonic waves and pulsed light have been used in physiotherapy to treat different disorders. In nuclear medicine, blood constituents(Bl-Co) are labeled with technetium-99m ( 99m Tc) are used. This study evaluated the consequences of magnetic field, radiofrequency and audible sonic waves and intense pulsed light sources on the labeling of Bl-Co with 99m Tc. Blood from Wistar rats was exposed to the cited sources. The labeling of Bl-Co with 99m Tc was performed. Blood not exposed to the physical agents was used(controls). Data showed that the exposure to the different studied sources did not alter significantly (p>0.05) the labeling of Bl-Co. Although the results were obtained with animals, the data suggest that no alteration on examinations performed with Bl-Co labeled with 99m Tc after exposition to the cited agents. The biological consequences associated with these agents would be not capable to interfere with some properties of the Bl-Co. (author)

  19. Consequences of the magnetic field, sonic and radiofrequency waves and intense pulsed light on the labeling of blood constituents with technetium-99m

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Patricia Froes; Costa, Iris do Ceu Clara; Brandao-Neto, Jose; Medeiros, Aldo da Cunha [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil). Programa de Pos-graduacao em Ciencias da Saude; Santos-Filho, Sebastiao David; Adenilson de Souza da Fonseca; Bernardo-Filho, Mario [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Inst. de Biologia Roberto Alcantara Gomes. Lab. de Radiofarmacia Experimental; Ariel Ronzio, Oscar [Universidad de Buenos Aires (Argentina); Bonelli, Ludmila [Universidade Salgado de Oliveira, Belo Horizonte, MG (Brazil)

    2007-09-15

    Sources of magnetic field, radiofrequency and audible sonic waves and pulsed light have been used in physiotherapy to treat different disorders. In nuclear medicine, blood constituents(Bl-Co) are labeled with technetium-99m ({sup 99m}Tc) are used. This study evaluated the consequences of magnetic field, radiofrequency and audible sonic waves and intense pulsed light sources on the labeling of Bl-Co with {sup 99m}Tc. Blood from Wistar rats was exposed to the cited sources. The labeling of Bl-Co with {sup 99m}Tc was performed. Blood not exposed to the physical agents was used(controls). Data showed that the exposure to the different studied sources did not alter significantly (p>0.05) the labeling of Bl-Co. Although the results were obtained with animals, the data suggest that no alteration on examinations performed with Bl-Co labeled with {sup 99m}Tc after exposition to the cited agents. The biological consequences associated with these agents would be not capable to interfere with some properties of the Bl-Co. (author)

  20. Evaluation of Deoxyribonucleic Acid Toxicity Induced by the Radiopharmaceutical 99mTechnetium-Methylenediphosphonic Acid and by Stannous Chloride in Wistar Rats

    Directory of Open Access Journals (Sweden)

    Adriano Caldeira-de-Araujo

    2012-11-01

    Full Text Available Radiopharmaceuticals are employed in patient diagnostics and disease treatments. Concerning the diagnosis aspect, technetium-99m (99mTc is utilized to label radiopharmaceuticals for single photon computed emission tomography (SPECT due to its physical and chemical characteristics. 99mTc fixation on pharmaceuticals depends on a reducing agent, stannous chloride (SnCl2 being the most widely-utilized. The genotoxic, clastogenic and anegenic properties of the 99mTc-MDP(methylene diphosphonate used for bone SPECT and SnCl2 were evaluated in Wistar rat blood cells using the Comet assay and micronucleus test. The experimental approach was to endovenously administer NaCl 0.9% (negative control, cyclophosphamide 50 mg/kg b.w. (positive control, SnCl2 500 μg/mL or 99mTc-MDP to animals and blood samples taken immediately before the injection, 3, and 24 h after (in the Comet assay and 36 h after, for micronucleus test. The data showed that both SnCl2 and 99mTc-MDP-induced deoxyribonucleic acid (DNA strand breaks in rat total blood cells, suggesting genotoxic potential. The 99mTc-MDP was not able to induce a significant DNA strand breaks increase in in vivo assays. Taken together, the data presented here points to the formation of a complex between SnCl2 in the radiopharmaceutical 99mTc-MDP, responsible for the decrease in cell damage, compared to both isolated chemical agents. These findings are important for the practice of nuclear medicine.

  1. Evaluating microvascular obstruction after acute myocardial infarction using cardiac magnetic resonance imaging and 201-thallium and 99m-technetium pyrophosphate scintigraphy

    International Nuclear Information System (INIS)

    Onishi, Takayuki; Kobayashi, Isshi; Onishi, Yuko; Kawashima, Tomoyuki; Muramoto, Hirotaka; Nakamura, Hiroaki; Nagata, Yasutoshi; Umezawa, Shigeo; Niwa, Akihiro

    2010-01-01

    Few studies have compared the ability of cardiac magnetic resonance (CMR) with that of scintigraphy using 201-thallium (201-Tl) and 99m-technetium pyrophosphate (99m-Tc PYP) to evaluate microvascular obstructions (MOs). In the present study the relationship between the scintigraphic and CMR characteristics of MOs after acute myocardial infarction (MI) was examined. The 14 patients (age 69±8 years, 11 males) underwent 201-Tl/99m-Tc PYP single photon emission computed tomography (SPECT) 7±3 days, initial CMR 16±12 days, and follow-up CMR 193±20 days after a reperfused first acute MI. Each image was analyzed using a 17-segment model. Segmental extent of delayed enhancement (DE), wall motion (WM) and degree of 201-Tl uptake were scored in 238 segments. Of 91 MI segments, MO was recognized in 22 (25%) segments on CMR. WM was significantly better in proportion to 201-Tl uptake (P=0.01) in MO segments. All 8 MO segments with WM improvement at follow-up had 99m-Tc PYP uptake, although only 3 (21%) of 14 MO segments that did not show WM improvement at follow-up had 99m-Tc PYP uptake (P=0.001). 99m-Tc PYP and 201-Tl scintigraphy have the potential to predict WM status and improvement of the MO region after reperfused acute MI. (author)

  2. Myocardial perfusion scintigraphy with technetium99m-MIBI in the diagnosis of coronary artery disease in women

    International Nuclear Information System (INIS)

    Peix, A.T.; Chacon, D.; Ponce, F.; Torres, M.; Llerena, L.; Lopez, A.; Cabrera, O.; Maltas, A.M.; Carrillo, R.

    2002-01-01

    Aim: To assess the value of myocardial perfusion scintigraphy for coronary artery disease (CAD) in women, we compared the results of a technetium99m-methoxy-isobutyl-isonitrile ( 99m Tc-MIBI) scintigraphy with those of a coronary angiography in a group of women referred for evaluation of chest pain. Material and Methods: Twenty women, 15 of them postmenopausal, were included. A 99m Tc-MIBI myocardial scintigraphy with one-day protocol (rest-stress) was performed. When needed, a combined stress (ergometric plus dipyridamole) was used. Both qualitative and quantitative regional uptake analysis was done. In patients with normal coronary arteries and positive myocardial scintigraphies, measurements were made of serum cholesterol and triglycerides (CHOD-PAD enzymatic colorimetric test), and lipoprotein(a) -Lp(a)- (BioSCREEN Lp(a) method). Results: Change in regional uptake (stress/rest) was as follows: during stress 99m Tc-MIBI, 116 segments had normal uptake (from 93±9% to 94±7%), 52 had moderately reduced uptake (from 67±9% to 75±17%), and 12 had severely reduced uptake (from 33±9% to 64±28%). Qualitative and quantitative analysis coincided in 18 cases. The two non-coincident cases were patients in whom qualitative analysis and coronary angiography were normal, but on quantitative analysis it appeared a reversible defect in one case and a 'reverse redistribution' pattern in the other. Breast attenuation defects were detected in four cases. Myocardial scintigraphy and coronary angiography coincided in 70% cases (figure). The remainder 30% was constituted by patients with positive scintigraphy and normal coronary arteries; among these cases, the 71% were postmenopausal and had systolic hypertension, chest pain at rest, positive ergometric test and hypercholesterolemia (table). Conclusion: We concluded that 99m Tc-MIBI myocardial scintigraphy can help in the CAD diagnosis in postmenopausal women

  3. Study of the leaf extract of cauliflower (Brassica oleracea L. var. Botrytis) in the blood elements labelling using Technetium-99m: possible consequences for the radiation dose modification

    International Nuclear Information System (INIS)

    Lima, E.A.C.; Dire, G.; Mattos, D.M.M.; Gomes, M.L.; Freitas, R.S.; Bernardo Filho, M.; Instituto Nacional do Cancer, Rio de Janeiro, RJ

    2001-01-01

    The radiation dose that a patient receives is also associated with the number of expositions to radiation sources. The labeling of blood elements with technetium-99m can be reduced by vegetable extracts and it can determine the repetition of the exam. The labeling procedure depends on a reducing agent and stannous chloride is used. We have evaluated the influence of an extract of cauliflower (leaf) on the labeling of blood elements with technetium-99m the and the results showed that this extract was not capable to alter the labeling procedure, suggesting that the studied extract does not have redox activity sufficiently to oxidize the stannous ions. Moreover, although, other natural extracts might alter this labeling, increasing the radiation dose to the patient, this fact would not occur to the cauliflower. (author)

  4. Biodistribution Study of the Anaesthetic Sodium Phenobarbital Labelled with Technetium-99m in Swiss Mice Infected with Schistosoma mansoni Sambon, 1907

    Directory of Open Access Journals (Sweden)

    Susana Balmant Emerique Simões

    1997-09-01

    Full Text Available Technetium-99m (99mTc is a radionuclide that has negligible enviromnental impact, is easily available, inexpensive and can be used as a radioactive tracer in biological experiences. In order to know the mode of action of sodium phenobarbital in moving adult Schistosoma mansoni worms from mesenteric veins to the liver, we labelled sodium phenobarbital (PBBT with 99mTc and a biodistribution study in infected and non-infected Swiss mice was performed. The PBBT was incubated with stannous chloride used as reducing agent and with 99mTc, as sodium pertechnetate. The radioactivity labelling (% was determined by paper ascending chromatography perfomed with acetone (solvent. The 99mTc-PBBT was administered by intraperitoneal route to Swiss mice infected eight weeks before. The animals were perfused after diferent periods of time (0,1,2,3,4 hr when blood, spleen, liver, portal vein, mesenteric veins, stomach, kidneys and adult worms were isolated. The radioactivity present in these samples was counted in a well counter and the percentage was determined. The radioactivity was mainly taken up by the blood, kidney, liver and spleen. No radioactivity was found on the adult worms. We concluded that the worm shift was due to an action on the host of the sodium phenobarbital

  5. Liver scanning with sup(99m)Tc-phytate

    Energy Technology Data Exchange (ETDEWEB)

    Kubo, A; Isobe, Y; Kobayashi, T; (Keio Univ., Tokyo (Japan). School of Medicine); Kinoshita, Fumio; Shibata, Masayoshi

    1975-03-01

    /sup 198/Au-colloid has been widely used for liver scanning in Japan but it is not the best scanning agent because of the large exposure dose to the patient. The authors performed a few basic experiments with sup(99m)Tc-phytate, the preparation of which is very easy. The labeling efficiency was found to be 97.5% immediately after preparation and it remained fairly stable for a period of time. As a result, the compound can be used up to 6 hours after preparation without fear of chemical instability. Liver scanning with sup(99m)Tc-phytate was done on 116 patients and was compared with /sup 198/Au-colloid liver-scanning. Scans made with sup(99m)Tc were found to be superior to those made with /sup 198/Au in the resolution of surface defects in the liver, while at increasing depths the resolution with sup(99m)Tc dropped rapidly, apparently due to absorption of its relatively low energy photon. This indicates the importance of taking multidirectional views. The degrees of splenic concentration of sup(99m)Tc-phytate were fairly close to those of /sup 198/Au-colloid. Therefore, liver scanning with sup(99m)Tc-phytate is useful in the diagnostic evaluation of diffuse parenchymal liver disease.

  6. Liver scanning with sup(99m)Tc-phytate

    International Nuclear Information System (INIS)

    Kubo, Atsushi; Isobe, Yoshinori; Kobayashi, Takeshi; Kinoshita, Fumio; Shibata, Masayoshi.

    1975-01-01

    198 Au-colloid has been widely used for liver scanning in Japan but it is not the best scanning agent because of the large exposure dose to the patient. The authors performed a few basic experiments with sup(99m)Tc-phytate, the preparation of which is very easy. The labeling efficiency was found to be 97.5% immediately after preparation and it remained fairly stable for a period of time. As a result, the compound can be used up to 6 hours after preparation without fear of chemical instability. Liver scanning with sup(99m)Tc-phytate was done on 116 patients and was compared with 198 Au-colloid liver-scanning. Scans made with sup(99m)Tc were found to be superior to those made with 198 Au in the resolution of surface defects in the liver, while at increasing depths the resolution with sup(99m)Tc dropped rapidly, apparently due to absorption of its relatively low energy photon. This indicates the importance of taking multidirectional views. The degrees of splenic concentration of sup(99m)Tc-phytate were fairly close to those of 198 Au-colloid. Therefore, liver scanning with sup(99m)Tc-phytate is useful in the diagnostic evaluation of diffuse parenchymal liver disease. (auth.)

  7. Sup(99m)Tc compounds for diagnostic purposes

    International Nuclear Information System (INIS)

    Cifka, J.; Budsky, F.

    1980-01-01

    The applications of sup(99m)Tc in nuclear medicine are discussed, such as sodium pertechnetate in thyroid and brain scintigraphy, complex compounds in lungs and liver diao.nosis. Technetium generators are classified according to the method of separating sup(99m)Tc from 99 Mo. Adsorption generators are used, molybdate-99 is adsorbed on an Al 2 O 3 -packed column while pertechnetate-99m is eluted with 0.9% NaCl solution. Also used is continuous pertechnetate-99m extraction with methyl ethyl ketone from 0.5 M potassium molybdate and 2.5 M of potassium carbonate. The manufacture is described of kits for sup(99m)Tc radiopharmaceuticals preparation, eg., Diagos I, a gluconate complex, a lyophilisate for sup(99m)Tc-sodium pyrophosphate injections, a diagnostic kit for lung scintiscanning. (H.S.)

  8. Technetium-99m-labeled deoxynivalenol from Fusarium mycotoxin alters organ toxicity in BALB/c mice by oral and intravenous route

    International Nuclear Information System (INIS)

    Chattopadhyay, P; Pandey, A; Goyary, D; Chaurasia, A; Singh, L; Veer, V.

    2012-01-01

    The toxicity of deoxynivalenol, both intravenously and orally, was investigated in male and female BALB/c mice. Technetium-99m ( 99m Tc)-labeled deoxynivalenol was administered to mice by tail vein injection and orally dosed. Distribution of labeled deoxynivalenol at 26 hours was monitored by gamma scintigraphy. In the evaluated organs, the accumulation of radioactive deoxynivalenol was correlated with the amount of radioactivity. In addition, the toxicity of deoxynivalenol was measured by biochemical assays followed by histopathological findings. Kidney and hepatic marker enzymes were significantly increased in intravenously administered deoxynivalenol as compared to orally treated mice. Intravenously treated mice showed severe damage in liver and kidney when compared to those orally exposed. Biodistribution of 99m Tc-labeled deoxynivalenol differed between oral and intravenous treatment. In intravenously exposed mice, deoxynivalenol was distributed primarily in the liver and kidney whereas in oral exposure, it was found in the stomach and intestines after 26 hours. Deoxynivalenol toxicity, associated with its biodistribution and organ toxicity, was greatest where it had accumulated. The results show that the toxicity of deoxynivalenol is associated with organ accumulation. (author)

  9. Survey of /sup 99m/Tc contamination of laboratory personnel: hand decontamination

    International Nuclear Information System (INIS)

    Nishiyama, H.; Van Tuinen, R.J.; Lukes, S.J.; Feller, P.A.

    1980-01-01

    Decontamination after exposure to various /sup 99m/Tc radiopharmaceuticals was tested with serial hand washings both with and without soap. All radiopharmaceuticals were removed more effectively with soap and the degree of decontamination related closely to the number of washings. The affinity of the radiopharmaceuticals for the skin varied, depending upon the labeled material, and only macroaggregated albumin was effectively removed to less than 1% of its original activity with soap. Activity transfer to the opposite hand could be substantial with macroaggregated albumin and sulfur colloid if soap is not used

  10. Study of factors that interfere in the labelling process of erythrocytes and plasma proteins with Technetium-99m; Estudo de fatores que interferem no processo de marcacao de hemacias e proteinas plasmaticas com tecnecio-99m

    Energy Technology Data Exchange (ETDEWEB)

    Gutfilen, Bianca

    1990-12-31

    The labelling of red blood cells (RBC) with technetium-99m (Tc-99m) depends on several factors, as the stannous ion (Sn++) concentration, time, temperature, the presence of plasma proteins (PP) and others. However the Sn++ concentration seems to be the most important factor; probably because the uptake of this reducing agent by RBC is limited. The excess of Sn++ in extracellular medium can determine the labelling of PP. the modifications of RBC at 50 deg C described in the literature, the possibility of labelling RBC with Tc-99m at this temperature and experimental results obtained made it possible to perform spleen selective scintigraphy through a simple technique with few manipulations. The effect of gentamicin, nifedipine and verapamil in the labelling of RBC and plasma proteins with Tc-99m was studied because of similarities between Ca++ and Sn++. The results show that, under some conditions, these drugs are capable to alter this Tc-99m incorporation. The modification of the ionic distribution determined by these drugs or the blockage of Sn++ and/or Tc-99m or the fact that they bind theirselves to plasma proteins, or the possibility of the labelling of these drugs, are factors that can interfere in the labelling process of red blood cells and plasma proteins with Tc-99m. (author) 55 refs., 12 figs., 5 tabs.

  11. Study of factors that interfere in the labelling process of erythrocytes and plasma proteins with Technetium-99m; Estudo de fatores que interferem no processo de marcacao de hemacias e proteinas plasmaticas com tecnecio-99m

    Energy Technology Data Exchange (ETDEWEB)

    Gutfilen, Bianca

    1989-12-31

    The labelling of red blood cells (RBC) with technetium-99m (Tc-99m) depends on several factors, as the stannous ion (Sn++) concentration, time, temperature, the presence of plasma proteins (PP) and others. However the Sn++ concentration seems to be the most important factor; probably because the uptake of this reducing agent by RBC is limited. The excess of Sn++ in extracellular medium can determine the labelling of PP. the modifications of RBC at 50 deg C described in the literature, the possibility of labelling RBC with Tc-99m at this temperature and experimental results obtained made it possible to perform spleen selective scintigraphy through a simple technique with few manipulations. The effect of gentamicin, nifedipine and verapamil in the labelling of RBC and plasma proteins with Tc-99m was studied because of similarities between Ca++ and Sn++. The results show that, under some conditions, these drugs are capable to alter this Tc-99m incorporation. The modification of the ionic distribution determined by these drugs or the blockage of Sn++ and/or Tc-99m or the fact that they bind theirselves to plasma proteins, or the possibility of the labelling of these drugs, are factors that can interfere in the labelling process of red blood cells and plasma proteins with Tc-99m. (author) 55 refs., 12 figs., 5 tabs.

  12. Status of {sup 99}Mo-{sup 99m}Tc production development by (n, {gamma}) reaction

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, Kunihiko; Kaminaga, Masanori; Ishihara, Masahiro; Kawamura, Hiroshi [Japan Atomic Energy Agency, Oarai Research and Development Center, Oarai, Ibaraki (Japan); Mutalib, Abdul [National Nuclear Energy Agency of Indonesia (BATAN), Tangerang (Indonesia); Chakrov, Petr [Institute of Nuclear Physics, National Nuclear Center of Republic of Kazakhstan (INP-NNC-RK), Almaty (Kazakhstan)

    2012-03-15

    Technetium-99m ({sup 99m}Tc) is one of the most commonly used radioisotopes in the field of nuclear medicine. As one of effective uses of the JMTR, JAEA has a plan to produce {sup 99}Mo by (n, {gamma}) method, a parent nuclide of {sup 99m}Tc. JAEA has performed R and D on production method of {sup 99}Mo-{sup 99m}Tc in JMTR cooperating with foreign organizations and relevant Japanese enterprises under the cooperation programs. In this paper, present status of R and D for production of {sup 99}Mo-{sup 99m}Tc in JMTR under international cooperation is introduced and constructions of the irradiation and PIE facilities at the JMTR site are also described. (author)

  13. Technetium-99m labeling and fibronectin binding ability of Corynebacterium diphtheriae; Marcacao de Corynebacterium diphtheriae com Tecnecio-99m e avaliacao da capacidade de ligacao a fibronectina de plasma humano

    Energy Technology Data Exchange (ETDEWEB)

    Souza, S.M.S.; Nagao, P.E.; Bernardo-Filho, M. [Universidade do Estado do Rio de Janeiro, RJ (Brazil). Inst. de Biologia Roberto Alcantara Gomes; Pereira, G.A.; Napoleao, F.; Andrade, A.F.B.; Hirata Junior, R.; Mattos-Guaraldi, A.L. [Universidade do Estado do Rio de Janeiro, RJ (Brazil). Faculdade de Ciencias Medicas

    2004-04-15

    The use of radionuclides has permitted advances in areas of clinical and scientific knowledge. Several molecules and cells have been labelled with Technetium-99m ({sup 99m}Tc). The stannous chloride (SnCl{sub 2}) has a significant influence on the labeling and stability of {sup 99m}Tc radiotracers. The frequent risk of diphtheria epidemics has intensified interest in the virulence factors of Corynebacterium diphtheriae. Although studies have looked at potential adhesins including haemagglutinins and exposed sugar residues, the molecular basis of mechanisms of adherence remains unclear. Adherence of pathogens to mammalian tissues may be mediated by fibronectin (FN) found in body fluids, matrix of connective tissues, and cell surfaces. In the present study we evaluated the binding ability to human plasma FN by {sup 99m}Tc labeled-C.diphtheriae. Due to adverse effects of stannous ions, microorganisms were submitted to survival and filamentation induction assays. Data showed a dose dependent susceptibility to SnCl{sub 2} bactericidal effects. Cell filamentation was observed for concentrations of SnCl{sub 2} > 110 {mu}g/ml. Adherence levels of {sup 99m}Tc labelled 241strain to coverslips coated with 20 {mu}g/ml FN were higher (P = 0.0037) than coated with bovine serum albumin. FN binding by the sucrose fermenting 241 C. diphtheriae strain (8.9% + 2.6) was significantly lower (P=0.0139) than Staphylococcus aureus Cowan I strain (34.1% {+-} 1.2). Therefore, bacterial {sup 99m}Tc labeling represents an additional tool that may contribute to the comprehension of C. diphtheriae interactions with host receptors such as FN that act as biological organizers by holding bacterial cells in position and guiding their migration. (author)

  14. Tumor affinity of technetium-99m labeled radiopharmaceuticals. II. Sup(99m)Tc-Sn-diphosphonate (sup(99m)Tc-EHDP), sup(99m)Tc-Sn-dimercaptosuccinic acid (sup(99m)Tc-DMSA), sup(99m)Tc-Sn-diethyl stilbestrol diphosphate (sup(99m)Tc-DSDP)

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, K; Kobayashi, S; Hisada, K; Tonami, N [Kanazawa Univ. (Japan). School of Medicine; Ando, A

    1976-10-01

    The authors have examined the tumor affinity of various sup(99m)Tc-labelled radiopharmaceuticals to Ehrlich's tumor for the purpose of delineating human malignant neoplasm positively. The biologic distributions of sup(99m)Tc-Sn-diphosphonate (sup(99m)Tc-EHDP), sup(99m)Tc-Sn-dimercaptosuccinic acid (sup(99m)Tc-DMSA) and sup(99m)Tc-Sn-diethyl stilbestrol diphosphate (sup(99m)Tc-DSDP, sup(99m)Tc-Honvan) are included as the second report on the tumor affinity of Ehrlich-bearing mice. Tumor concentration of sup(99m)Tc-EHDP was lowest and the positive delineation of implanted tumor with sup(99m)Tc-EHDP was poorest in sequential images, though active accumulation in some soft tissues malignant neoplasms, breast cancer, and thyroid cancer, has been reported. Tumor concentration and the tumor-to-blood ratio of sup(99m)Tc-DMSA were not so high, contrary to our expectation that /sup 197/Hg-DMSA might show high tumor concentration and high tumor-to-blood ratio the same as /sup 197/Hg chlormerodrin of the renal scanning radiopharmaceuticals. Tumor concentration of sup(99m)Tc-DSDP was highest. The tumor-to-blood concentration ratio was lower than that of the above mentioned radiopharmaceuticals but the tumor-to-liver ratio and/or tumor-to-lung ratio was over 1.0 at the earlier time. Biologic distribution of sup(99m)Tc-DSDP was similar to that of /sup 32/P labeled DSDP. It is presumed that sup(99m)Tc is labeled at the phosphate ester of DSDP which is dephospholytated immediately by phospholylase in vivo following intravenous injection. Although it is not known precisely it may be assumed that the mechanism of accumulating sup(99m)Tc-DSDP in Ehrlich's tumor is related to the phospholylase activity in neoplasms.

  15. Techneticum-99m pharmaceuticals. Preparation and quality control in nuclear medicine

    International Nuclear Information System (INIS)

    Zolle, I.

    2007-01-01

    Radioactive drug development is a multi-disciplinary task, therefore, in a concerted effort, dedicated scientists and experts from different fields of specialisation have contributed to this book. It is presented in two sections. Section 1 contains basic principles and methods used for analysis, information on the chemistry of technetium and on radiopharmaceuticals labelled with technetium-99m, the characteristics of the 99 Mo/99mTc-generator, of 'kits' and formulations for in-vitro labelling, and special safety aspects for in-vivo labelling of blood cells. Section 2 contains monographs of 99mTc-radiopharmaceuticals used in nuclear medicine. Each monograph includes information on the chemistry, formulation, commercial products and trade names, factors affecting in-vivo performance, clinical information on pharmacokinetics, as well as details concerning the clinical application and the radiation dose to patients. (orig.)

  16. Technetium Behavior and Recovery in Soil

    Energy Technology Data Exchange (ETDEWEB)

    Meinken,G.E.

    1995-12-01

    Technetium-99 in soils is of great concern because of its long half-life and because it can not be detected readily. This work reviews the behavior of technetium in various types of soils. A method for extracting technetium from soil was developed with the use of technetium-95m and 99m to determine recoveries at each step. Technetium chemistry is very complicated and problem areas in the behavior and recovery have been highlighted. Technetium is widely used in nuclear medicine and a review of its chemistry pertaining to radiopharmaceuticals is relevant and helpful in environmental studies. The technetium behavior in the patented citric acid method for the removal of toxic metals in contaminated soils was studied. An innovative method using solid phase extraction media for the concentration of technetium extracted from soils, with water and hydrogen peroxide, was developed. This technique may have a useful environmental application for this type of remediation of technetium from contaminated soils.

  17. Technetium behavior and recovery in soil

    International Nuclear Information System (INIS)

    Meinken, G.E.

    1995-12-01

    Technetium-99 in soils is of great concern because of its long half-life and because it can not be detected readily. This work reviews the behavior of technetium in various types of soils. A method for extracting technetium from soil was developed with the use of technetium-95m and 99m to determine recoveries at each step. Technetium chemistry is very complicated and problem areas in the behavior and recovery have been highlighted. Technetium is widely used in nuclear medicine and a review of its chemistry pertaining to radiopharmaceuticals is relevant and helpful in environmental studies. The technetium behavior in the patented citric acid method for the removal of toxic metals in contaminated soils was studied. An innovative method using solid phase extraction media for the concentration of technetium extracted from soils, with water and hydrogen peroxide, was developed. This technique may have a useful environmental application for this type of remediation of technetium from contaminated

  18. Age-related changes in the global skeletal uptake of technetium-99m methylene diphosphonate in healthy women

    International Nuclear Information System (INIS)

    Carnevale, V.; Frusciante, V.; Scillitani, A.; Modoni, S.; Pileri, M.; Chiodini, I.; Dicembrino, F.; Romagnoli, E.; Minisola, S.

    1996-01-01

    A short-term evaluation of global skeletal uptake (GSU) of technetium-99m methylene diphosphonate (MDP) was performed in 40 healthy female subjects with a wide age range in order to investigate the clinical performance of the technique and to detect the age-related changes in bone turnover. The results obtained were compared with measurements of the main biochemical markers of skeletal metabolism. We found that GSU increases progressively with age, independently of concomitant changes in renal function; significant correlations with biochemical markers of bone formation were also found. Therefore, the method appears to provide useful information concerning the bone turnover rate, and is also applicable to elderly people owing to its simplicity. (orig.). With 4 figs., 2 tabs

  19. Functional scintiscanning with sup(99m)technetium-diethyl-HIDA as a nuclear diagnostical means in hepatobiliary diseases

    International Nuclear Information System (INIS)

    Hummel, G.

    1982-01-01

    The study aimed to delimit the value of sequential hepatobiliary scintiscanning with the aid of sup(99m)technetium-diethyl-HIDA as a diagnostical method in functional or morphological disorders of the gall bladder and bile ducts. The most frequent indications to carry through the investigation therefore were inflammations calculosis in the biliary system, suspected intrahepatic icterus or conditions following biliodigestive anastomoses. Special attention was directed to the question in how far the results were in accordance with those of x-ray cholecystography/cholangiography. Furthermore the possibility for semiquantitative evaluation of serial functional scintiscanning was looked into and clearance determinations were carried through in part of the patients investigated. (orig./MG) [de

  20. Comparison of exercise stress testing with dobutamine stress echocardiography and exercise technetium-99m isonitrile single photon emission computerized tomography for diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Oguzhan, A.; Kisacik, H.L.; Ozdemir, K.

    1997-01-01

    To compare the value of exercise electrocardiography with dobutamine stress echocardiography and exercise technetium-99m isonitrile single-photon emission computed tomography for coronary artery disease, 70 patients with either suspected or proven coronary artery disease underwent dobutamine stress echocardiography, exercise technetium-99m isonitrile single-photon emission computed tomography (mibi-SPECT) and treadmill exercise electrocardiography (ECG). Dobutamine echocardiography and exercise mibi-SPECT revealed a higher overall sensitivity than exercise testing (90 vs 57%, p 0.05; 90 and 62% p<0.05, respectively) but the difference between dobutamine stress echocardiography and exercise mibi-SPECT was not statistically significant. Diagnostic accuracy of dobutamine stress echocardiography and exercise mibi-SPECT was higher than that of exercise testing (90 vs 59%, p<0.001; 89 vs 59%, p<0.001, respectively). Dobutamine stress echocardiography and exercise mibi-SPECT have superiority over exercise testing in the diagnosis of coronary artery disease and dobutamine stress echocardiography is an alternative for exercise mibi-SPECT. (author)

  1. Contribution for labelling study of cellular and molecular structures of biomedical interest with technetium 99

    International Nuclear Information System (INIS)

    Rebello, L.H.; Piotkwosky, M.C.; Pereira, J.A.A.; Boasquevisque, E.M.; Silva, J.R.M.; Reis, R.J.N.; Pires, E.T.; Bernardo-Filho, M.

    1992-01-01

    The methodologies for labelling bacteria, planaria and cercaria from schistosomiasis evolution cycle and in oxamniquine with technetium 99 m, developed in the Biomedical Center of Rio de Janeiro University and in the Research Center of National Institute of Cancer are shown. (C.G.C.)

  2. Clearance of technetium-99m-labeled DTPA in hyperthyroidism without clinical evidence of lung disease, and relation to pulmonary function

    International Nuclear Information System (INIS)

    Guldiken, S.; Tugrul, A.; Altiay, G.; Hacimahmutoglu, S.; Durmus-Altun, G.

    2005-01-01

    The mechanisms of dyspnea and exercise intolerance have not been fully elucidated. We aimed to investigate the clearance rate of technetium-99m diethyltriaminepentaaceticacid (Tc-99m DTPA) from lungs in hyperthyroid patients without clinical evidence of lung disease and to explore the interactions between their Tc-99m DTPA radioaerosol lung scintigraphy, spirometric measurements, and the levels of thyroid hormones. We studied 19 hyperthyroid patients and 16 sex- and age-matched controls. Thyroid hormone levels were assessed. Spirometric lung function tests, diffusing capacity of the lung for carbon monoxide (DLCO) and the clearance rate of Tc-99m DTPA were performed in all participants. Ratio of DLCO value to the alveolar ventilation (DLCO/VA) and the means of half-time (T 1/2 ) of Tc-99m DTPA clearance rate, which were used to evaluate alveolar-capillary membrane permeability, were calculated. There were no statistical differences between spirometric parameters (vital capacity (VC), force vital capacity (FVC), one second forced expiratory volume (FEV 1 )/FVC, mean forced expiratory flow during the middle of FVC (FEF 25-75)) of the two groups (p>0.05). Although the mean FEV 1 level was significantly lower in the hyperthyroid patients than the control subjects (p 1 was only less than 80 percent of the predicted value. No significant difference in the means of DLCO, DLCO/VA or T 1/2 values of Tc-99m DTPA clearance was observed between the two groups (p>0.05). In hyperthyroid patients, there was a positive relation between DLCO/VA, DLCO/VA% and T 1/2 values of Tc-99m DTPA clearance (p 1/2 values of Tc-99m DTPA clearance in hyperthyroid group (p>0.05). We conclude that increased thyroid hormones have no effect on permeability of alveolar-capillary membrane in hyperthyroid patients. (author)

  3. Determination of Technetium-99 in Environmental Samples by Solvent Extraction at Controlled Valence

    DEFF Research Database (Denmark)

    Chen, Q.J.; Aarkrog, A.; Dahlgaard, H.

    1989-01-01

    Distribution coefficients of technetium and ruthenium are determined under different conditions with CCl4, cyclohexanone, and 5% tri-isooctylamine (TIOA)/xylene. A method for analyzing 99Tc in environmental samples has been developed by solvent extraction in which the valences of technetium...

  4. Effect of acidity and chemical composition of sup(99m)Tc-radiopharmaceuticals on sup(99m)Tc accumulation in necrotic tissue of rat myocardium

    Energy Technology Data Exchange (ETDEWEB)

    Vilcek, S; Machan, V; Kalincak, M [Ustav Radioekologie a Vyuzitia Jadrovej Techniky, Kosice (Czechoslovakia); Nicak, A [Univerzita P.J. Safarika, Kosice (Czechoslovakia). Lekarska Fakulta

    1981-04-30

    Experiments showed that the cumulation of technetium-99m following the administration of /sup 99m/Tc-Sn-pyrophosphate and s/sup 99m/Tc-Sn-oxytetracycline in the necrotic tissue of rat myocardium damaged by cauterization depended on the end pH value. The maximum /sup 99m/Tc cumulation in the myocardial lesion was noted when the end pH value ranged in 5.5 to 6.0. It appeared that pyrophosphate concentration decrease below the critical limit not only affected the cumulation of /sup 99m/Tc in the particular organs but also in the necrotic tissue of the myocardium.

  5. Effect of acidity and chemical composition of sup(99m)Tc-radiopharmaceuticals on sup(99m)Tc accumulation in necrotic tissue of rat myocardium

    International Nuclear Information System (INIS)

    Vilcek, S.; Machan, V.; Kalincak, M.; Nicak, A.

    1981-01-01

    Experiments showed that the cumulation of technetium-99m following the administration of sup(99m)Tc-Sn-pyrophosphate and sup(99m)Tc-Sn-oxytetracycline in the necrotic tissue of rat myocardium damaged by cauterization depended on the end pH value. The maximum sup(99m)Tc cumulation in the myocardial lesion was noted when the end pH value ranged in 5.5 to 6.0. It appeared that pyrophosphate concentration decrease below the critical limit not only affected the cumulation of sup(99m)Tc in the particular organs but also in the necrotic tissue of the myocardium. (author)

  6. An aqueous extract of Vitex agnus castus alters the labeling of blood constituents with technetium-99m

    Directory of Open Access Journals (Sweden)

    Maria Regina de Macedo Costa

    2007-09-01

    Full Text Available The development of experimental assays to study properties of herbal medicine is worthwhile. Vitex agnus castus (VAC is utilized in popular medicine and some actions have been attributed to its extract. Blood cells (BC and plasma proteins are labeled with technetium-99m (Tc-99m and have been used in nuclear medicine, as in basic research. This procedure uses a reducing agent and stannous ion is utilized. There are reports that drugs can alter this labeling process. The aim of this work was to evaluate the influence of an aqueous extract of VAC on the labeling of blood constituents with Tc-99m. Blood was incubated with VAC, stannous chloride and Tc-99m, as sodium pertechnetate, and centrifuged. Samples of BC and plasma were separated, aliquots of BC and plasma were also precipitated with trichloroacetic acid to obtain soluble and insoluble fractions and the percentage of radioactivity (%ATI was determined. The results show a statistical (pModelos experimentais são relevantes no estudo de propriedades de plantas medicinais. Vitex agnus castus (VAC é usado na medicina popular. Células sanguíneas (CS e proteínas plasmáticas são marcadas com tecnécio-99m (Tc-99m com aplicações na medicina nuclear e em pesquisa. Esse procedimento utiliza um agente redutor e o íon estanoso é usado. Drogas podem alterar esse processo de marcação. O objetivo desse trabalho foi avaliar a influência de um extrato aquoso de VAC na marcação de constituintes sanguíneos com Tc-99m. Sangue foi incubado com VAC, cloreto estanoso e Tc-99m, como pertecnetato de sódio e centrifugado. Amostras de CS e plasma foram separadas, alíquotas de CS e plasma foram também precipitadas com ácido tricloroacético para obtenção de frações solúvel (FS e insolúvel (FI e a percentagem de radioatividade (%ATI foi determinada. Os resultados mostraram uma alteração estatística (p<0.05 na %ATI dos compartimentos sanguíneos e nas FI do plasma e CS. Provavelmente, esse

  7. Positron tomographic imaging of the liver: 68Ga iron hydroxide colloid

    International Nuclear Information System (INIS)

    Kumar, B.; Miller, T.R.; Siegel, B.A.; Mathias, C.J.; Markham, J.; Ehrhardt, G.J.; Welch, M.J.

    1981-01-01

    A new radiopharmaceutical, 68 Ga iron hydroxide colloid, for hepatic imaging by positron emission tomography was prepared from the eluate of a 68 Ge- 68 Ga solvent extraction generator. In rats, 84% of the administered dose of colloid localized in the liver and 4.6% accumulated in the spleen. Initial imaging studies in normal dogs showed close correspondence of the findings by positron tomography and transmission computed tomography. Emission tomography with 68 Ga-colloid was performed in 10 patients with hepatic metastases demonstrated by conventional /sup 99m/Tc-sulfur colloid scintigraphy. All focal defects noted on the conventional scintigrams were easily identified and generally were seen more clearly by positron tomography. In one patient, additional lesions not identified on the initial /sup 99m/Tc-sulfur colloid images were demonstrated. The positron tomographic images were compared with those obtained by transmission computed tomography in seven patients; the two studies showed comparable findings in five patients, whereas positron tomography more clearly showed multiple lesions in two. Our results suggest that positron emission tomography is a suitable technique for obtaining high contrast, cross-sectional images of large abdominal organs

  8. Positron tomographic imaging of the liver: 68Ga iron hydroxide colloid

    International Nuclear Information System (INIS)

    Kumar, B.; Miller, T.R.; Siegel, B.A.; Mathias, C.J.; Markham, J.; Ehrhardt, G.J.; Welch, M.J.

    1981-01-01

    A new radiopharmaceutical, 68 Ga ion hydroxide colloid, for hepatic imaging by positron emission tomography was prepared from the eluate of a 68 Ge- 68 Ga solvent extraction generator. In rats, 84% of the administered dose of colloid localized in the liver and 4.6% accumulated in the spleen. Initial imaging studies in normal dogs showed close correspondence of the findings by positron tomography and transmission computed tomography. Emission tomography with 68 Ga-colloid was performed in 10 patients with hepatic metastases demonstrated by conventional 99mTc sulfur colloid scintigraphy. All focal defects noted on the conventional scintigrams were easily identified and generally were seen more clearly by positron tomography. In one patient, additional lesions not identified on the initial 99mTc sulfur colloid images were demonstrated. The positron tomographic images were compared with those obtained by transmission computed tomography in seven patients; the two studies showed comparable findings in five patients, whereas positron tomography more clearly showed multiple lesions in two. Our results suggest that positron emission tomography is a suitable technique for obtaining high contrast, cross-sectional images of large abdominal organs

  9. Effect of an Arctium lappa (burdock) extract on the labeling of blood constituents with technetium-99m and on the morphology of the red blood cells

    International Nuclear Information System (INIS)

    Neves, Rosane de Figueiredo; Rebello, Bernardo Machado; Medeiros, Aldo da Cunha; Moreno, Silvana Ramos Farias; Fonseca, Adenilson de Souza da; Caldas, Luiz Querino de Araujo; Bernardo-Filho, Mario

    2007-01-01

    Arctium lappa (burdock) has been used to treat inflammatory processes. Blood constituents labeled with technetium-99m ( 99m Tc) have been utilized in nuclear medicine. It was evaluated the influence of a burdock extract on the labeling of blood constituents with 99m Tc and on the morphometry of red blood cells. Blood samples from Wistar rats were incubated with burdock extract and the radiolabeling procedure was carried out. Plasma and blood cells, soluble and insoluble fractions of plasma and blood cells were separated. The radioactivity in each fraction was counted and the percentages of radioactivity (%ATI) were determined. Morphology and morphometric (perimeter/area ratio) measurements of red blood cells (RBC) were performed. The incubation with burdock extract significantly (p 99m Tc obtained in this study. (author)

  10. Stability studies on 99mTechnetium(III) complexes with tridentate/monodentate thiol ligands and phosphine ('3+1+1' complexes)

    International Nuclear Information System (INIS)

    Seifert, Sepp; Drews, Antje; Gupta, Antje; Pietzsch, Hans-Juergen; Spies, Hartmut; Johannsen, Bernd

    2000-01-01

    The preparation and characterisation of 3+1+1 technetium complexes of the general formula [Tc(SES)(RS)(PMe 2 Ph)] (SES=tridentate dithiol ligand, E=S, O, NMe; RSH=monothiol ligand) at the n.c.a. level is described. The Tc(III) complexes are prepared in a one-step procedure starting from pertechnetate in yields of 85-95% of radiochemical purity. A comparison of their chromatographic data with the fully characterised 99 Tc complexes indicate the identity of the investigated compounds. Stability studies show that the 99m Tc complexes undergo some alteration in solution. They are oxidised to the 3+1 oxotechnetium (V) complexes and/or decompose in aqueous solution. In challenge experiments performed with glutathione, exchange of the monothiolato ligand occurs in the same manner as known for the 3+1 complexes

  11. Lyophilized kits of diamino dithiol compounds for labelling with 99m-technetium. Pharmacokinetics studies and distribution compartmental models of the related complexes

    International Nuclear Information System (INIS)

    Araujo, Elaine Bortoleti de

    1995-01-01

    The present work reflects the clinical interest for labelling diamino dithiol compounds with technetium-99m. Both chosen compounds, L,L-Ethylene dicysteine (L,L-EC) and L,L-Ethylene dicysteine diethyl esther (L,L-ECD) were obtained with relative good yield and characterized by IR and NMR. The study of labelling conditions with technetium-99m showed the influence of the type and mass of reducing agent as well as the pH on the formation of complexes with desired biological characteristics. Radiochemical purity was determined by thin layer chromatography (TLC) and high performance liquid chromatography (HPLC). Lyophilised kits of L,L-EC and L,L-ECD for labelling with 99m Tc were obtained, with stability superior to 120 days, when stored under refrigeration, enabling the kits marketing. The ideal formulation of the kits as well as the use of liquid nitrogen in the freezing process, determined the lyophilization success. Distribution biological studies of the 99m Tc complexes were performed on mice by invasive method and on bigger animals by scintigraphic evaluation. Biological distribution studies of the complex 99m Tc-L,L-EC showed fast blood clearance, with the elimination of about 90% of the administered dose after 60 minutes, almost exclusively by the urinary system. The biological distribution results were adjusted to a three compartmental distribution model, as expected for a radiopharmaceutical designed to renal dynamic studies, with tubular elimination. The complex interaction with renal tubular receptors is related with structural characteristics of the compound, more specifically with the presence and location of polar groups. In comparison with 99m Tc-L,L-EC, biological studies of the complex 99m Tc -L,L-ECD showed different distribution aspects, despite some structural similarities. The presence of ethyl groups confers to the complex neutrality and lipophilicity. It cross the intact blood brain barrier and is retained in the brain for enough period

  12. Technetium-99m sestamibi myocardial tomography based on dipyridamole echocardiography testing in hypertensive patients with chest pain

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, O. [Section of Nuclear Medicine, Department of Experimental Medicine and Pathology, University ``La Sapienza``, Rome (Italy); Moroni, C. [Department of Internal Medicine, University ``La Sapienza``, Rome (Italy); Scopinaro, F. [Section of Nuclear Medicine, Department of Experimental Medicine and Pathology, University ``La Sapienza``, Rome (Italy); Tavolaro, R. [Section of Nuclear Medicine, Department of Experimental Medicine and Pathology, University ``La Sapienza``, Rome (Italy); Danieli, R. [Section of Nuclear Medicine, Department of Experimental Medicine and Pathology, University ``La Sapienza``, Rome (Italy); Bossini, A. [Department of Internal Medicine, University ``La Sapienza``, Rome (Italy); Cassone, R. [Department of Internal Medicine, University ``La Sapienza``, Rome (Italy); Colella, A.C. [Section of Nuclear Medicine, Department of Experimental Medicine and Pathology, University ``La Sapienza``, Rome (Italy)

    1997-07-01

    The aim of this study was to evaluate the diagnostic capability of technetium-99m sestamibi tomography based on dipyridamole echocardiography testing in hypertensives with chest pain, and to compare the scintigraphic results with those of coronary angiography, exercise electrocardiography and dipyridamole echocardiography. Forty subjects with mild to moderate hypertension, chest pain and no previous myocardial infarction were submitted to {sup 99m}Tc-sestamibi tomography (at rest and after high-dose dipyridamole echocardiography) and to exercise electrocardiography testing. At coronary angiography 22 patients (group A) had significant epicardial coronary artery disease ({>=}70% stenosis of at least one major vessel) and 18 normal main coronary vessels (group B). Dipyridamole {sup 99m}Tc-sestamibi imaging was positive in 21/22 patients of group A and in 5/18 of group B. Dipyridamole echocardiography was positive in 18/22 patients of group A and in 5/18 of group B. Exercise electrocardiography was positive in 15/22 patients of group A and in 11/18 of group B. Four out of five subjects in group B with positive results in all the tests showed a slow run-off of angiographic contrast medium, probably due to small-vessel disease. Significant epicardial coronary artery disease in hypertensives with chest pain is unlikely when dipyridamole {sup 99m}Tc-sestamibi tomography is negative. When scintigraphy is positive, either epicardial coronary artery disease or a small-vessel disease condition is possible. The association of scintigraphy with dipyridamole echocardiography testing allows the assessment of contractile function and myocardial perfusion by a single pharmacological stress. (orig./AJ). With 3 figs., 2 tabs.

  13. Production of technetium-99m in the Institute of Nuclear Physics of the National Nuclear Center of the Republic of Kazakhstan

    International Nuclear Information System (INIS)

    Chakrov, P.V.; Bannykh, V.I.; Chakrova, E.T.; Tamaeva, K.; Zhotabaev, Zh.R.

    2002-01-01

    Institute of Nuclear Physics NNC RK, Almaty, Kazakhstan 'National Nuclear Center, Kurchatov, Kazakhstan In order to organize local production of Technetium-99m radiopharmaceutical in Kazakhstan, research, development and technological work has been carried out at the Laboratory of Radiochemistry, Institute of Nuclear Physics NNC RK, in the period of 1999-2001. The technology developed is based on the so-called 'gel method', which allows to use activated natural molybdenum for production of pertechnetate solution with high radioactive concentration. Along with development of chemical process and design of central Tc-generator, a significant attention was paid to installation of quality control techniques. Complex quality control of technetium eluate from the central gel-type generator was performed, including determination of radionuclidic purity, radiochemical purity, chemical composition, content of elemental impurities, sterility, etc. It was found that pertechnetate produced meets the requirements of Russian and European Pharmacopoeias. High quality of radiopharmaceutical was confirmed subsequently in both pre-clinical and clinical tests performed by three medical centers in Almaty. 72 diagnostic examinations of patients with various diagnoses have been carried out during clinical tests. The radiopharmaceutical S odium pertechnetate solution, Tc-99m produced in the Institute of Nuclear Physics NNC RK is officially registered and permitted for use in Kazakhstan, and its regular supply to Almaty clinics has been started in the year 2002

  14. Dissemination of bacteria labeled with technetium-99m after laparotomy and abdominal insufflation with different CO2 pressures on rats; Disseminacao de bacterias marcadas com tecnecio-99m apos laparotomia e insuflacao com diferentes pressoes de CO2 em ratos

    Energy Technology Data Exchange (ETDEWEB)

    Pitombo, Marcos Bettini; Faria, Clarice Abreu dos Santos Albuquerque de; Steinbruck, Klaus [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Escola de Medicina]. E-mail: mpitombo@urbi.com.br; Bernardo, Luciana Camargo; Bernardo Filho, Mario[Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Inst. de Biologia Roberto Alcantara Gomes (IBRAG). Lab. de Radiofarmacia Experimental

    2008-01-15

    Purpose: To asses the dissemination of bacteria labeled with technetium-99m (99mTc) from peritoneal cavity after different surgical procedures. Methods: Bacteria of the Escherichia coli species labeled with 99mTc were used in a concentration of 108 units of colony-makers for ml (UFC/ml) and 1 ml was inoculated through intra-peritoneal via. Forty-eight rats were divided into four groups: control, laparotomy, pneumoperitoneum with 10 mmHg and pneumoperitoneum with 20 mmHg of CO2. Procedures were performed 20 min after injection of the inoculum and lasted 30 min. Animals were sacrificed after six hours (Group 1) and 24 hours (Group 2). Samples of blood, liver and spleen were collected for radioactivity counting. Results: After six hours, indirect detection of the bacteria in different organs was uniform in all groups. After 24 hours, a larger detection of technetium was observed in the livers of animals of the group insufflated with 20 mmHg of CO2, when compared with those of control group (p<0.01). The other groups did not present statistically significant variations. Conclusions: The use of a higher intra-abdominal pressure was associated with a higher bacterial dissemination to the liver. The application of lower intra-abdominal pressures may be associated with a lower dissemination of the infectious status during laparoscopic approach of peritonitis status. (author)

  15. Labeling cellular elements of blood with Technetium-99m

    Energy Technology Data Exchange (ETDEWEB)

    Dewanjee, M.K.

    1990-08-01

    The purpose of this proposal is to develop new technique of labeling platelets and white cells with Tc-99m radionuclide. The conditions of labeling canine platelets and white cells with the lipid-soluble Tc-99m HMPAO have been optimized. The function of labeled platelets were evaluated by the determination of platelet survival time and recovery and these values were compared with that of In-111 tropolone labeled platelets. We developed the bilateral femoral catheterization model for the evaluation of platelet-thrombosis on control and heparin-bonded catheters in dogs. We are evaluating platelet thrombosis in the hollow-fiber hemodialyzer with Tc-99m and In-111 labeled platelets. We have developed the flow-loop for in vitro studies and are using a pig model for quantitation of platelet-consumption during hemodialysis. We are currently evaluating the new technique of platelet and white cell-labeling with Tc-99m and testing them in animal models of thrombosis and infection (osteo-myelitis). We are also using the Tc-99m HMPAO labeled mixed white cells in the early diagnosis (3-hour post-injection) of acute and chronic infection in patients and comparing the results with that of IN-111 oxine labeled white cells.

  16. In-house cyclotron production of high-purity Tc-99m and Tc-99m radiopharmaceuticals.

    Science.gov (United States)

    Martini, Petra; Boschi, Alessandra; Cicoria, Gianfranco; Zagni, Federico; Corazza, Andrea; Uccelli, Licia; Pasquali, Micòl; Pupillo, Gaia; Marengo, Mario; Loriggiola, Massimo; Skliarova, Hanna; Mou, Liliana; Cisternino, Sara; Carturan, Sara; Melendez-Alafort, Laura; Uzunov, Nikolay M; Bello, Michele; Alvarez, Carlos Rossi; Esposito, Juan; Duatti, Adriano

    2018-05-30

    In the last years, the technology for producing the important medical radionuclide technetium-99m by cyclotrons has become sufficiently mature to justify its introduction as an alternative source of the starting precursor [ 99m Tc][TcO 4 ] - ubiquitously employed for the production of 99m Tc-radiopharmaceuticals in hospitals. These technologies make use almost exclusively of the nuclear reaction 100 Mo(p,2n) 99m Tc that allows direct production of Tc-99m. In this study, it is conjectured that this alternative production route will not replace the current supply chain based on the distribution of 99 Mo/ 99m Tc generators, but could become a convenient emergency source of Tc-99m only for in-house hospitals equipped with a conventional, low-energy, medical cyclotron. On this ground, an outline of the essential steps that should be implemented for setting up a hospital radiopharmacy aimed at the occasional production of Tc-99m by a small cyclotron is discussed. These include (1) target production, (2) irradiation conditions, (3) separation/purification procedures, (4) terminal sterilization, (5) quality control, and (6) Mo-100 recovery. To address these issues, a comprehensive technology for cyclotron-production of Tc-99m, developed at the Legnaro National Laboratories of the Italian National Institute of Nuclear Physics (LNL-INFN), will be used as a reference example. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. The use of "9"9"mTc-Al_2O_3 for detection of sentinel lymph nodes in breast cancer

    International Nuclear Information System (INIS)

    Sinilkin, I.; Chernov, V.; Medvedeva, A.; Zeltchan, R.; Slonimskaya, E.; Doroshenko, A.; Varlamova, N.; Skuridin, V.

    2016-01-01

    Purpose: to study the feasibility of using the new radiopharmaceutical based on the technetium-99m-labeled gamma-alumina for identification of sentinel lymph nodes (SLNs) in breast cancer patients. The study included two groups of breast cancer patients who underwent single photon emission computed tomography (SPECT) and intraoperaive gamma probe identification of sentinel lymph nodes (SLNs). To identify SLNs, the day before surgery Group I patients (n = 34) were injected with radioactive "9"9"mTc-Al_2O_3, and Group II patients (n = 30) received "9"9"mTc-labeled phytate colloid. A total of 37 SLNs were detected in Group I patients. The number of identified SLNs per patient ranged from 1 to 2 (the average number of identified SLNs was 1.08). Axillary lymph nodes were the most common site of SLN localization. 18 hours after "9"9"mTc-Al_2O_3 injection, the percentage of its accumulation in the SLN was 7–11% (of the counts in the injection site) by SPECT and 17–31% by gamma probe detection. In Group II SLNs were detected in 27 patients. 18 hours after injection of the phytate colloid the percentage of its accumulation in the SLN was 1.5–2% out of the counts in the injection site by SPECT and 4–7% by gamma probe. The new radiopharmaceutical based on the "9"9"mTc-Al_2O_3 demonstrates high accumulation in SLNs without redistribution through the entire lymphatic basin. The sensitivity and specificity of "9"9"mTc-Al_2O_3 were 100% for both SPECT and intraoperative gamma probe identification.

  18. Identification of Hürthle cell tumor by single-injection, double-phase scintigraphy with technetium-99m-sestamibi.

    Science.gov (United States)

    Vattimo, A; Bertelli, P; Cintorino, M; Burroni, L; Volterrani, D; Vella, A

    1995-05-01

    Early and late (double-phase) scintigraphy with 99mTc-MIBI was used in a comparative study of the scintigraphic aspects of Hürthle cell tumors and other thyroid tumors. Single-injection, dual-phase (15-30 min and 3-4 hr) thyroid scintigraphy with 99mTc-sestamibi (MIBI) was performed on 41 patients who displayed a cold nodule on previous 99mTc scintigraphy. Visual scoring of nodular uptake was done to compare thyroidal and background tracer uptake. In addition, the nodular-to-thyroid (N/T) uptake ratio in the early and late images and the washout rate from the nodule (WON) and thyroidal tissue (WOT) were measured. Cytologic results were obtained for all patients; histopathologic results were obtained for the 20 patients who had surgery. In eight patients (Group A), the nodule displayed intense and persistent uptake of MIBI (N/T = 1.77 +/- 0.46 and 3.20 +/- 1.37; WON = 17.2% +/- 6.3%; WOT = 24.6% +/- 7.5%); histopathology revealed Hürthle cell tumors (two carcinomas and three adenomas) in five surgical patients. In 15 patients (Group B), the nodule displayed intense uptake in the early image with fading activity in the late image (N/T = 1.45 +/- 0.54 and 0.84 +/- 0.30; WON = 30.0% +/- 7.3%; WOT = 24.5% +/- 6.8%); histopathology revealed a colloid nodule (n = 1), papillary carcinoma (n = 4) and follicular carcinoma (n = 5) in 10 surgical patients. In the remaining 18 patients (Group C), the nodule was cold and late images were not acquired. Histopathology revealed colloid nodules (n = 2) and follicular adenoma (n = 3) in five surgical patients. Single-injection, dual-phase MIBI scintigraphy of the thyroid can identify Hürthle cell tumors because these tumors have intense, persistent tracer uptake in contrast to other thyroid tumors.

  19. A study of technetium-labelled sulphide colloid uptake by regional lymph nodes draining a tumour-bearing area

    International Nuclear Information System (INIS)

    Boak, J.L.; Agwunobi, T.C.

    1978-01-01

    With appropriate controls, experimental groups of inbred C 3 H mice bearing a syngeneic mammary carcinoma challenge in their right rear footpads were injected in both rear footpads with 99 Tcsup(m)ASC. Mice were sacrificed 15 and 90 min after the labelled colloid injection. Popliteal and sacral lymph nodes were weighed and counted in a well scintillation counter. A marked inhibition of labelled colloid uptake was demonstrated in regional lymph nodes draining a tumour-bearing area. Rabbits bearing VX 2 carcinoma in a forelimb received 99 Tc sup(m)ASC into each front footpad. Depression of labelled colloid uptake by regional lymph nodes draining tumour was evident on gamma-camera scanning. (author)

  20. Technetium-99m--pyrophosphate bone scans in hyperparathyroidism

    International Nuclear Information System (INIS)

    Wiegmann, T.; Rosenthall, L.; Kaye, M.

    1977-01-01

    Most patients with primary hyperparathyroidism have normal 5-hr bone-to-soft-tissue ratios for /sup 99m/Tc-pyrophosphate. In contrast, all five patients with advanced secondary hyperparathyroidism in this study showed significant (p less than 0.001) increases of bone uptake. In the early period after parathyroidectomy, there was no quantitative or qualitative change in uptake. A limited decrease of bone uptake was observed only after prolonged periods of observation. In itself, parathyroid activity seems to have little direct influence on bone uptake of /sup 99m/Tc-pyrophosphate