WorldWideScience

Sample records for technetium pyrophosphate scan

  1. Ligand-free, protein-bound technetium-99m iron-dextran enhancement of technetium pyrophosphate uptake in tumours

    International Nuclear Information System (INIS)

    Pojer, P.M.; Jakovljevic, A.C.; Wise, K.N.

    1985-01-01

    The biodistribution of technetium-99m was studied in T-cell lymphoma and selected organs of iron-dextran treated and control mice given technetium-99m pyrophosphate. The results showed that high serum iron levels increased tumour uptake of technetium pyrophosphate. This supports the hypothesis that technetium, in common with other metal-based tumour seeking radiopharmaceuticals, is transported to tumours as a ligand-free protein-bound cation. (U.K.)

  2. Investigation of the interaction of hydroxyapatite with technetium in association with stannous pyrophosphate

    International Nuclear Information System (INIS)

    Billinghurst, M.W.; Jette, D.; Somers, E.

    1981-01-01

    The individual components of technetium-99m stannous pyrophosphate were studied with respect to their interaction with hydroxyapatite. It is demonstrated that the role of the pyrophosphate molecule is one of a solubilizing and transporting molecule to carry the technetium atom to the site of the hydroxyapatite where the chelate disassociates and both the pyrophosphate and the technetium individually bind to the hydroxyapatite. The stannous ion is shown to associate with the hydroxyapatite also and although also solubilized by the pyrophosphate appears to be less strongly associated with the pyrophosphate. (author)

  3. Detection of unstable angina by /sup 99m/technetium pyrophosphate myocardial scintigraphy

    International Nuclear Information System (INIS)

    Abdulla, A.M.; Canedo, M.I.; Cortez, B.C.; McGinnis, K.D.; Wilhelm, S.K.

    1976-01-01

    /sup 99m/Technetium stannous pyrophosphate has been shown to accumulate in acutely infarcted myocardium. To determine if the isotope is also taken up by severely ischemic, but not necrotic myocardium, we performed myocardial scintigraphic studies in 17 patients with chest pains. Seven of the patients satisfied conventional clinical, electrocardiographic, and laboratory criteria for the diagnosis of unstable angina and showed no electrocardiographic or enzymatic evidence of myocardial necrosis. Five of these seven patients with unstable angina demonstrated abnormal localized patterns, and one showed a borderline picture. Myocardial scintiscans were normal in all of a control group of ten patients with stable angina. Thus, scanning with /sup 99m/technetium stannous pyrophosphate is shown to be of value in the objective demonstration of myocardial abnormality in unstable angina

  4. 99m Technetium pyrophosphate myocardium scintigraphy. First results

    International Nuclear Information System (INIS)

    Toussaint, Paul.

    1976-01-01

    99m technetium pyrophosphate myocardium scintigraphy is a very recent examination technique. This work gives the results obtained on 61 patients. As a vector of the isotope, pyrophosphate has the advantage over polyphosphate of a fast bone uptake there it should be stressed that a 90 minute pause is necessary between the intraveinous injection of the isotope and the photographic recording so that the reading is not troubled by the labelled intracardiac blood pool image, an image quality criterion being the estimation of a good costal fixation which in fact appears sooner or later according to the subject. The role of pyrophosphate, chelator of calcium in fixation of the isotope on the myocardium, could be explained by the fast appearance of 'dense bodies', made up of calcium hydroxyapathice crystals, in the mitochondria of myocardium cells having undergone an irreversible necrotic process. The choice of 99 m technetium is based on its ease of use: 6 hour half-life, high-energy pure gamma emission at 140 keV. The fixed image studied under two incidences, front and left anterior oblique, is obtained from mobile images given by the scintillation camera used in connection with a data processing system. Several facts are underlined, explaining the disadvantages, advantages and indications of the method [fr

  5. Recognition of reversible and irreversible myocardial injury by technetium pyrophosphate extraction kinetics

    International Nuclear Information System (INIS)

    Silva, R.; Chen, Y.F.; Sell, T.L.; Lowe, J.E.; Jones, R.H.

    1987-01-01

    The need for a more accurate method of detecting episodes of myocardial ischemia during cardiac operations, particularly during the ischemic arrest interval, prompted us to investigate the usefulness of measuring the active extraction of technetium pyrophosphate in identifying and quantitating ischemic injury. Twenty-four adult mongrel dogs were subjected to cardiopulmonary bypass, and normothermic global ischemia was induced by cross-clamping the proximal aorta. Technetium pyrophosphate (1 mCi) was injected through a standard cardioplegia line with normal saline, simulating administration of cardioplegic solution, upon placement of the aortic cross-clamp (time 0), at 15, 30, 45, and 60 minutes of global ischemia, and with the onset and completion of ischemic contracture. Radioactive counts were recorded over the heart at 1 second intervals, and the extraction fraction and half-time of clearance were calculated. The extraction fraction increased from 0.22 at time 0 to 0.58 at 15 minutes, 0.82 at 30 minutes, 0.85 at 45 minutes, and 0.91 at 60 minutes. The halftime increased from a baseline of 114 seconds (time 0) to a maximum of 321 seconds at 60 minutes of ischemia. The onset and completion of ischemic contracture showed a return toward baseline of both the extraction fraction and halftime of clearance, with an extraction fraction of 0.44 and 0.46 and a halftime of 135 and 133 seconds, respectively. These data clearly show that reversible myocardial injury increased the extraction and reduced the clearance of technetium pyrophosphate and that the magnitude of change related to the extent of injury. The progression to irreversible myocardial injury decreased the active extraction of technetium pyrophosphate. This simple procedure for real-time documentation of myocardial injury promises to provide easily obtainable endpoints of injury for use during cardiac operations in humans

  6. Technetium-99m--pyrophosphate bone scans in hyperparathyroidism

    International Nuclear Information System (INIS)

    Wiegmann, T.; Rosenthall, L.; Kaye, M.

    1977-01-01

    Most patients with primary hyperparathyroidism have normal 5-hr bone-to-soft-tissue ratios for /sup 99m/Tc-pyrophosphate. In contrast, all five patients with advanced secondary hyperparathyroidism in this study showed significant (p less than 0.001) increases of bone uptake. In the early period after parathyroidectomy, there was no quantitative or qualitative change in uptake. A limited decrease of bone uptake was observed only after prolonged periods of observation. In itself, parathyroid activity seems to have little direct influence on bone uptake of /sup 99m/Tc-pyrophosphate

  7. Diagnostic value of technetium pyrophosphate bone scintigraphy. Study of 277 patients

    International Nuclear Information System (INIS)

    Sainte-Croix, Annick.

    1975-01-01

    277 bone scintigraphs were carried out with 99m technetium pyrophosphate and an attempt was made, on the basis of this experience, to define the advantages and limits of the technique. 99m technetium pyrophosphate seems to be the isotope most suitable for bone scintigraphy. The scintillation camera bone scintigraphic examination is simple, allowing the whole skeleton to be explored in a relatively short time, and above all harmless since the total irradiation to which the organism is exposed throughout is no more than 0.07 rad. The broadest field of application of bone scintigraphy appears to be cancer: in 45 cases out of 66 it revealed bone metastases invisible radiologically and in 28 cases out of 90 the number of metastases observed was greater than that shown by X-rays. In 11 cases however radiologically visible bone metastases were not detected by scintigraphy. In spite of this reservation we consider bone scintigraphy to be a valuable technique, more sensitive than X-ray examinations in the detection of bone metastases of cancers [fr

  8. Muscle necrosis in the extremities: evaluation with Tc-99m pyrophosphate scanning--a retrospective review

    International Nuclear Information System (INIS)

    Timmons, J.H.; Hartshorne, M.F.; Peters, V.J.; Cawthon, M.A.; Bauman, J.M.

    1988-01-01

    A retrospective review was done of 34 extremities studied between 1981 and 1985 with technetium-99m pyrophosphate scanning; 22 were subsequently amputated. Results of detailed pathologic examination or immediate postoperative examination of the resected extremity were available in 16 cases. In these cases, scanning had allowed correct prediction of the level of amputation and of the specific areas of muscle infarction in 13 cases. In the one case in which amputation was performed for infection rather than muscle necrosis, the lack of necrosis was correctly predicted with the scan. The limited results of this study indicate that the Tc-99m pyrophosphate scan allows the location of necrotic muscle to be predicted accurately and may therefore be a useful adjunct in determining the best level for ultimate amputation. Special caution is required in those cases in which muscle necrosis is due to acute causes (e.g., traumatic thrombosis) rather than chronic vascular disease

  9. Clinical significance of technetium-99m stannous pyrophosphate myocardial scintigrams in patients with acute and old myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Kanazawa, Ikuo; Eno, Shin; Takeuchi, Masaaki

    1987-08-01

    Seventy-five consecutive patients with acute (43) or old (32) myocardial infarction (AMI, OMI) have been examined by myocardial scintiscanning with technetium-99m stannous pyrophosphate (PYP). Using Parker's classification, the PYP scans were graded as positive in 56 % of the AMI patients; in restricting to the PYP scans obtained within the first 3 days after the onset, the positive rate was 86 %. Positive or negative PYP scans for the AMI patients were independent of maximum creatine phosphokinase and infarct site. For OMI patients, the PYP scans were positive in 41 %, with decreased left ventricular function being more common than those having negative PYP scans. In the group of positive scans, clinical manifestations tended to be remarkable, which were likely due to persistent cardiac ischemia during chronic stage. (Namekawa, K.).

  10. Contribution of technetium pyrophosphate bone scintigraphy in the evaluation of prostate cancer extension based on 100 cases

    International Nuclear Information System (INIS)

    Oliveux, Alain.

    1976-01-01

    The aim of this work was to compare the results of technetium 99m pyrophosphate bone scintigraphy with those of the standard radiographic exploration of the skeleton in order to find out whether scintigraphic data allow an earlier and more accurate diagnosis of the presence of bone metastases. The dose administered is about 10MCi per patient; the recording is made 4 hours after intraveinous injection of the tracer. The documents are obtained in two stages: - first of all a whole-body scintigraph is carried out by means of an 'omniview' system adapted to the Picker dynacamera. This instrument gives an image of the entire body by translation of the patient's bed before the detection head of the camera; - immediately after the whole-body scan a series of static views is taken, especially on abnormal or doubtful areas. These documents have a better resolution than the reduced whole-body image and supply complementary data all the more valuable as they are directed towards the zones of interest. Analysis of our observations underlines the advantages of technetium 99m pyrophosphate bone scintigraphy in the evaluation of prostate neoplasm extension. This particularly sensitive method of investigation enables bone metastases to be detected earlier and more precisely in a patient presenting a neoplasm [fr

  11. Early estimation of acute myocardial infarct size soon after coronary reperfusion using emission computed tomography with technetium-99m pyrophosphate

    International Nuclear Information System (INIS)

    Hashimoto, T.; Kambara, H.; Fudo, T.; Tamaki, S.; Nohara, R.; Takatsu, Y.; Hattori, R.; Tokunaga, S.; Kawai, C.

    1987-01-01

    Early appearance of positive findings on a technetium-99m pyrophosphate scan has been shown to be associated with the presence of a reperfused acute myocardial infarction (AMI). Early technetium-99m pyrophosphate imaging was performed by emission computed tomography to evaluate reperfusion and to test the feasibility of estimating infarct size soon after coronary reperfusion based on acute positive tomographic findings. Twenty-seven patients with transmural AMI who were treated with intracoronary urokinase infusion followed by percutaneous transluminal coronary angioplasty underwent pyrophosphate imaging 8.7 +/- 2.1 hours after the onset of AMI. None of the 8 patients in whom reperfusion was unsuccessful had acute positive findings. Of 19 patients in whom reperfusion was successful, 17 had acute positive findings (p less than 0.001). In these 17, tomographic infarct volumes were determined from reconstructed transaxial images. The threshold for areas of increased pyrophosphate uptake within the infarct was set at 60% of peak activity by the computerized edge-detection algorithm. The total number of pixels in all transaxial sections showing increased tracer uptake were added and multiplied by a size factor and 1.05 g/cm3 muscle to determine infarct volume. The correlations of tomographic infarct volumes with peak serum creatine kinase (CK) levels (r = 0.82) and with cumulative release of CK-MB isoenzyme (r = 0.89) were good. Moreover, the time to positive imaging was significantly shorter than that to peak CK level (8.5 +/- 2.3 vs 10.4 +/- 2.2 hours, p less than 0.005)

  12. Technetium-99m pyrophosphate imaging in acute renal failure associated with nontraumatic rhabdomyolysis

    Energy Technology Data Exchange (ETDEWEB)

    Patel, R.; Mishkin, F.S.

    1986-10-01

    Technetium-99m pyrophosphate (Tc-PYP) imaging was performed in five patients with acute renal failure associated with nontraumatic rhabdomyolysis. Four patients had phencyclidine intoxication and one had viral pneumonia. During the acute phase, marked uptake of pyrophosphate was seen in all patients in several muscle groups, but always in the thigh adductors. The results show that phencyclidine intoxication can result in diffuse muscle uptake of Tc-PYP without overt evidence of muscle injury. Tc-PYP imaging may provide a clue to the cause of acute renal failure in patients with suspected rhabdomyolysis in whom elevations of serum creatine phosphokinase concentrations are equivocal.

  13. Technetium-99m pyrophosphate imaging in acute renal failure associated with nontraumatic rhabdomyolysis

    International Nuclear Information System (INIS)

    Patel, R.; Mishkin, F.S.

    1986-01-01

    Technetium-99m pyrophosphate (Tc-PYP) imaging was performed in five patients with acute renal failure associated with nontraumatic rhabdomyolysis. Four patients had phencyclidine intoxication and one had viral pneumonia. During the acute phase, marked uptake of pyrophosphate was seen in all patients in several muscle groups, but always in the thigh adductors. The results show that phencyclidine intoxication can result in diffuse muscle uptake of Tc-PYP without overt evidence of muscle injury. Tc-PYP imaging may provide a clue to the cause of acute renal failure in patients with suspected rhabdomyolysis in whom elevations of serum creatine phosphokinase concentrations are equivocal

  14. Technical problems associated with the production of technetium Tc 99m tin(II) pyrophosphate kits

    International Nuclear Information System (INIS)

    Kowalsky, R.J.; Dalton, D.R.

    1981-01-01

    The amount of tin(II) required for adequate reduction, complexation, and stability of technetium Tc 99m pertechnetate in radiopharmaceutical kits, and methods of preventing the loss of tin(II) during formulation of these lyophilized kits are investigated. Tin(II) loss from stannous chloride solutions was studied under several conditions, including room air versus nitrogen atmospheres, during vial filling in a laminar-flow hood with samples frozen on dry ice versus samples at room temperature, during lyophilization, and during storage under refrigerated, ambient, and elevated temperatures. Various amounts of stannous chloride, ranging from 5 to 1000 microgram/ml, were used in formulating sodium pertechnetate Tc 99m kits containing 100 mCi technetium Tc 99m and 0.4 microgram total technetium. Samples were removed at various times; hydrolyzed technetium, pertechnetate, and technetium Tc 99m pyrophosphate were isolated on instant thin-layer chromatography-silica gel and quantified with a scintillation counter. The time necessary to deoxygenate distilled water by nitrogen purging was measured. Several sources of stannous chloride were assayed for tin(II) content. Tin(II) loss occurs rapidly in solution (15% in one hour) unless continuously protected with nitrogen, and during vial filling in a laminar-flow hood unless frozen with dry ice. No substantial loss of tin(II) was detected during lyophilization or during storage of lyophilized product at any of the three temperatures. A minimum of 400 microgram tin(II) was required to provide 90% technetium Tc 99m pyrophosphate at six hours after preparation. Adequate deoxygenation of small quantities (450 ml) of water was accomplished in less than one hour. Some stannous chloride salts were highly oxidized in the dry state, and only high-purity elemental tin wire gave acceptable yields of tin

  15. Contribution of technetium 99m-labelled pyrophosphate bone scintigraphy in infectious spondylodiscitis

    International Nuclear Information System (INIS)

    Capdepont, M.-T.

    1976-01-01

    This work examines the contribution of technetium 99m(sup(99m)Tc)-labelled pyrophosphate bone scintigraphy in infectious spondylodiscitis and attempts to define its importance in the diagnosis of lesions and their subsequent supervision in patients under treatment. 5 to 15 millicuries of sup(99m)Tc-labelled pyrophosphates are injected intraveinously. Bone uptake is strong and durable; 1.3% of the injected activity is found in the blood by the fifth hour. The skeleton may be explored: - either one segment at a tome with a scintillation camera, - or all at once and more quickly with a whole-body device taking front and black exposures. Bone scintigraphy appears as a basic technique in the study of infectious spondylodiscitis. Moreover the use of increasingly efficient equipment, the quantification of results and perhaps the development of new tracers augur well for a technique which is already acknowledged to be of fundamental interest [fr

  16. Emission computed tomography with technetium-99m pyrophosphate for delineating location and size of acute myocardial infarction in man

    Energy Technology Data Exchange (ETDEWEB)

    Tamaki, S; Kadota, K; Kambara, H; Suzuki, Y; Nohara, R; Murakami, T; Kawai, C; Tamaki, N; Torizuka, K [Kyoto Univ. (Japan). Faculty of Medicine

    1984-07-01

    Emission computed tomography with technetium-99m pyrophosphate was used to delineate the location and estimate the size of myocardial infarcts in 20 patients with documented acute myocardial infarction. Tomography was performed after planar imaging within 2-5 days after the onset of infarction. Infarct volume was measured from the tomographic images by computerised planimetry and compared with the cumulative release of creatine kinase MB isoenzyme. The planar images showed discrete myocardial uptake in 13 of the 20 patients and diffuse uptake throughout the cardiac region in the remaining seven. In contrast, the tomographic images clearly delineated myocardial uptake by avoiding confusion of myocardial activity with that of surrounding structures, particularly bones, in all patients. For the 10 patients whose infarct size was assessed by analysis of the creatine kinase MB curve there was a close correlation between infarct volume estimated by tomography and by cumulative creatine kinase MB release. Thus emission computed tomography can provide a three dimensional map of technetium-99m pyrophosphate distribution within the heart and is thus able accurately to localise and estimate the size of myocardial infarcts in man.

  17. Emission computed tomography with technetium-99m pyrophosphate for delineating location and size of acute myocardial infarction in man

    International Nuclear Information System (INIS)

    Tamaki, S.; Kadota, K.; Kambara, H.; Suzuki, Y.; Nohara, R.; Murakami, T.; Kawai, C.; Tamaki, N.; Torizuka, K.

    1984-01-01

    Emission computed tomography with technetium-99m pyrophosphate was used to delineate the location and estimate the size of myocardial infarcts in 20 patients with documented acute myocardial infarction. Tomography was performed after planar imaging within 2-5 days after the onset of infarction. Infarct volume was measured from the tomographic images by computerised planimetry and compared with the cumulative release of creatine kinase MB isoenzyme. The planar images showed discrete myocardial uptake in 13 of the 20 patients and diffuse uptake throughout the cardiac region in the remaining seven. In contrast, the tomographic images clearly delineated myocardial uptake by avoiding confusion of myocardial activity with that of surrounding structures, particularly bones, in all patients. For the 10 patients whose infarct size was assessed by analysis of the creatine kinase MB curve there was a close correlation between infarct volume estimated by tomography and by cumulative creatine kinase MB release. Thus emission computed tomography can provide a three dimensional map of technetium-99m pyrophosphate distribution within the heart and is thus able accurately to localise and estimate the size of myocardial infarcts in man. (author)

  18. Tc-99m pyrophosphate scanning after ischemic exercise in McArdle's disease

    International Nuclear Information System (INIS)

    Uno, Hideaki; Kawano, Keizo; Yukawa, Susumu; Nomoto, Hiroshi

    1982-01-01

    In order to clarify the mechanism of muscle contracture induced by ischemic exercise in a patient with McArdle's disease, bone scanning with Tc-99m pyrophosphate was performed. The clinical diagnosis was established in the patient based on the biochemical examinations of skeletal muscle biopsy. Ischemic exercise was done initially on the left forearm and then 20 hours later on the right forearm. Two hours later, 15 mCi of Tc-99m pyrophosphate was infused through the left antecubital vein. Exactly 4 hours later, a conventional bone scanning was carried out. In the patient with McArdle's disease, muscle contracture developed in both forearms during the ischemic exercise. Conventional bone scanning showed increased Tc-99m pyrophosphate labeling of the right forearm muscles at 2 hours after ischemic exercise. However, increased labeling of the left forearm muscles was not found at 22 hours after ischemic exercise. In the control, no muscle contracture developed during ischemic exercise and bone scan showed no increase in Tc-99m pyrophosphate labeling in the antebrachial region. These findings suggest that the basis of muscle contracture appears to be an increased concentration of Ca in muscle cells due to a failure of sarcoplasmic reticulum to reaccumulate Ca at ischemic exercise. (author)

  19. Technetium 99m pyrophosphate bone scintigraphy in the exploration of breast cancer bone metastases (analysis of 311 examinations)

    International Nuclear Information System (INIS)

    Bonichon, Francoise.

    1976-01-01

    Sodium pyrophosphate was chosen for its ease of application and the quality of the images it gives. The aim of this study, in the context of breast cancer exploration, is to examine: - its reliability for the detection of bone metastases, - the correlation of its results with other factors. The first part reviews the properties of sup(99m)Tc-labelled sodium pyrophosphate and the current hypotheses on the mechanism of its bone fixation, essential for an understanding of the image formation mechanism and for the interpretation of anomalies. Part two gives an analysis of 311 examinations carried out on 223 patients, obtained by the use of a coded file and modern data processing methods. The following are dealt with in turn: - material and methods, - the results themselves and especially their reliability for the whole skeleton and for one bone at a time, - discussion and comparison with published data. Sup(99m)Tc pyrophosphate bone scintigraphy is a simple examination easy to interpret and allows the whole skeleton to be explored. Abnormal scintigraphic images are: - seldom hypofixing lacunae, - usually 'hyperfixing centres' which point to a perilesional bone reaction and depend on: vascular factors, the affinity of technetium for the immature collagen fibres of the forming bone matrix, the affinity of pyrophosphate for the bone mineral substance [fr

  20. Quantitative analysis of acute myocardial infarction using single photon emission computed tomography using technetium-99m pyrophosphate

    International Nuclear Information System (INIS)

    Fujiwara, Yasushi; Kokubu, Tatsuo; Murase, Kenya; Hamamoto, Ken; Itoh, Taketoshi; Doiuchi, Junji; Ochi, Takaaki.

    1986-01-01

    The usefulness of single photon emission computed tomography (SPECT) using technetium-99m pyrophosphate ( 99m Tc-PPi) was evaluated in 15 patients with acute myocardial infarction. SPECT was performed with a rotating gamma camera after conventional planar images were made. Infarct size was measured from transaxial images of myocardial pyrophosphate uptakes. In each slice, the boundary was defined by subtracting 70 percent of the maximal counts and the number of voxels automatically counted. This subtraction rate was determined by phantom study and by compraing SPECT using 99m Tc-PPi with thallium-201-gated myocardial scintigraphy ( 201 Tl gated SPECT). The planar images showed diffuse uptakes in two of the 15 patients, and in these cases it was difficult to detect the infarct site. In contrast, SPECT images clearly imaged the infarct site consistent with the electrocardiographic findings, and they were definitely separated from the uptakes in the bones in all cases. Infarct size, ranging from 3.4 ml to 78.3 ml, correlated well with cumulative creatine kinase release (r = 0.84, p 99m Tc-PPi is a useful means of investigating the spatial distribution of pyrophosphate uptake and of evaluating the size of myocardial infarction. (author)

  1. Postoperative myocardial infarction documented by technetium pyrophosphate scan using single-photon emission computed tomography: Significance of intraoperative myocardial ischemia and hemodynamic control

    International Nuclear Information System (INIS)

    Cheng, D.C.; Chung, F.; Burns, R.J.; Houston, P.L.; Feindel, C.M.

    1989-01-01

    The aim of this prospective study was to document postoperative myocardial infarction (PMI) by technetium pyrophosphate scan using single-photon emission computed tomography (TcPPi-SPECT) in 28 patients undergoing elective coronary bypass grafting (CABG). The relationships of intraoperative electrocardiographic myocardial ischemia, hemodynamic responses, and pharmacological requirements to this incidence of PMI were correlated. Radionuclide cardioangiography and TcPPi-SPECT were performed 24 h preoperatively and 48 h postoperatively. A standard high-dose fentanyl anesthetic protocol was used. Twenty-five percent of elective CABG patients were complicated with PMI, as documented by TcPPi-SPECT with an infarcted mass of 38.0 +/- 5.5 g. No significant difference in demographic, preoperative right and left ventricular function, number of coronary vessels grafted, or aortic cross-clamp time was observed between the PMI and non-PMI groups. The distribution of patients using preoperative beta-adrenergic blocking drugs or calcium channel blocking drugs was found to have no correlation with the outcome of PMI. As well, no significant differences in hemodynamic changes or pharmacological requirements were observed in the PMI and non-PMI groups during prebypass or postbypass periods, indicating careful intraoperative control of hemodynamic indices did not prevent the outcome of PMI in these patients. However, the incidence of prebypass ischemia was 39.3% and significantly correlated with the outcome of positive TcPPi-SPECT, denoting a 3.9-fold increased risk of developing PMI. Prebypass ischemic changes in leads II and V5 were shown to correlate with increased CPK-MB release (P less than 0.05) and tends to occur more frequently with lateral myocardial infarction

  2. Postoperative myocardial infarction documented by technetium pyrophosphate scan using single-photon emission computed tomography: Significance of intraoperative myocardial ischemia and hemodynamic control

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, D.C.; Chung, F.; Burns, R.J.; Houston, P.L.; Feindel, C.M. (Toronto Hospital, Ontario (Canada))

    1989-12-01

    The aim of this prospective study was to document postoperative myocardial infarction (PMI) by technetium pyrophosphate scan using single-photon emission computed tomography (TcPPi-SPECT) in 28 patients undergoing elective coronary bypass grafting (CABG). The relationships of intraoperative electrocardiographic myocardial ischemia, hemodynamic responses, and pharmacological requirements to this incidence of PMI were correlated. Radionuclide cardioangiography and TcPPi-SPECT were performed 24 h preoperatively and 48 h postoperatively. A standard high-dose fentanyl anesthetic protocol was used. Twenty-five percent of elective CABG patients were complicated with PMI, as documented by TcPPi-SPECT with an infarcted mass of 38.0 +/- 5.5 g. No significant difference in demographic, preoperative right and left ventricular function, number of coronary vessels grafted, or aortic cross-clamp time was observed between the PMI and non-PMI groups. The distribution of patients using preoperative beta-adrenergic blocking drugs or calcium channel blocking drugs was found to have no correlation with the outcome of PMI. As well, no significant differences in hemodynamic changes or pharmacological requirements were observed in the PMI and non-PMI groups during prebypass or postbypass periods, indicating careful intraoperative control of hemodynamic indices did not prevent the outcome of PMI in these patients. However, the incidence of prebypass ischemia was 39.3% and significantly correlated with the outcome of positive TcPPi-SPECT, denoting a 3.9-fold increased risk of developing PMI. Prebypass ischemic changes in leads II and V5 were shown to correlate with increased CPK-MB release (P less than 0.05) and tends to occur more frequently with lateral myocardial infarction.

  3. Technetium-99m stannous pyrophosphate imaging of experimental infective endocarditis

    International Nuclear Information System (INIS)

    Riba, A.L.; Downs, J.; Thakur, M.L.; Gottschalk, A.; Andriole, V.T.; Zaret, B.L.

    1978-01-01

    Technetium-99m stannous pyrophosphate (/sup 99m/Tc-PYP) cardiac scintigraphy was performed in 15 rabbits with experimental Streptococcus sanguis aortic-valve infective endocarditis. The animals were imaged five to seven days after the administration of bacteria, and in each case abnormal accumulation of the tracer was visualized in the region of the aortic valve. Three types of cardiac scintigraphic patterns were demonstrated: focal, multifocal, and extensive, each correlating well with the anatomical extent of the lesion as defined by gross pathology. Tissue distribution studies demonstrated a 30 +- 5.3 (mean +- SEM) fold excess of radionuclide uptake in the infective endocarditis lesion compared with that of normal myocardium. Imaging of excised hearts from four animals showed an excellent correlation with in vivo imaging as well as gross pathology. Five animals with nonbacterial thrombotic aortic valve endocarditis demonstrated similar scintigraphic and tissue distribution results. In contrast, four normal animals failed to demonstrate abnormal /sup 99m/Tc-PYP cardiac scintigrams or tissue uptake. This study demonstrates that /sup 99m/Tc-PYP cardiac scintigraphy is a sensitive technique to detect experimental aortic valve endocarditis

  4. Quantitative analysis of acute myocardial infarction using single photon emission computed tomography using technetium-99m pyrophosphate

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, Yasushi; Kokubu, Tatsuo; Murase, Kenya; Hamamoto, Ken; Itoh, Taketoshi; Doiuchi, Junji; Ochi, Takaaki

    1986-09-01

    The usefulness of single photon emission computed tomography (SPECT) using technetium-99m pyrophosphate (/sup 99m/Tc-PPi) was evaluated in 15 patients with acute myocardial infarction. SPECT was performed with a rotating gamma camera after conventional planar images were made. Infarct size was measured from transaxial images of myocardial pyrophosphate uptakes. In each slice, the boundary was defined by subtracting 70 percent of the maximal counts and the number of voxels automatically counted. This subtraction rate was determined by phantom study and by compraing SPECT using /sup 99m/Tc-PPi with thallium-201-gated myocardial scintigraphy (/sup 201/Tl gated SPECT). The planar images showed diffuse uptakes in two of the 15 patients, and in these cases it was difficult to detect the infarct site. In contrast, SPECT images clearly imaged the infarct site consistent with the electrocardiographic findings, and they were definitely separated from the uptakes in the bones in all cases. Infarct size, ranging from 3.4 ml to 78.3 ml, correlated well with cumulative creatine kinase release (r = 0.84, p < 0.01, y = 772x + 13900). Correlation of infarct size with peak serum creatine kinase level was also significant (r = 0.66, p < 0.01, y = 10.6x + 693). In conclusion, SPECT with /sup 99m/Tc-PPi is a useful means of investigating the spatial distribution of pyrophosphate uptake and of evaluating the size of myocardial infarction.

  5. Study of technetium behaviour in radiopharmaceuticals. Characterization of sup(99m)Tc-pyrophosphate, sup(99m)Tc-dimercaptosuccinate, sup(99m)Tc-diethylenetriaminepentaacetate complexes and sup(99m)Tc-colloidal rhenium sulphide

    International Nuclear Information System (INIS)

    Saccavini, J.-C.

    1980-12-01

    The chemistry of technetium in extremely dilute solution was approached through the study of three complexing agents and a colloid. By the application of high-performance chromatographic techniques to the analysis of (Tc-pyro), (Tc-DTPA), (Tc-DMSA) complexes it was possible to isolate one or more chelates from a single complexing agent. Addition of pertechnetates to a solution of sodium pyrophosphates and stannous chloride at neutral pH leads to the formation of two complexes, both highly osteotropic. By the use of sup(117m)Sn it was shown that tin employed as reducing agent enters into the composition of one of the two complexes, either of which may be obtained preferentially by varying the (Sn)/(pyro) ratio. With technetium at acid pH (2.5) DMSA gives one or more chelates according to the concentration of the reagents present. DTPA with technetium at neutral pH gives a single complex for which a structure is proposed. The addition of calcium, indispensable for DTPA injection, leads to the appearance of a second bimetallic complex in very much smaller proportions than the first. The size distribution of some colloids was studied by ultrafiltration and permeation on gel. The preparation of colloidal rhenium sulphide and the technetium labelling conditions needed to obtain a very fine colloid were developed. The behaviour of technetium in the presence of colloidal rhenium sulphide and tin pyrophosphate was followed by sup(99m)Tc - sup(186)Re and sup(99m)Tc - sup(117m)Sn double-labelling tests. One reduced technetium fraction associates with the hydrolysed tin, the other follows the rhenium sulphide [fr

  6. Pyrophosphate scan of the temporarily ischemized dog myocardium

    Energy Technology Data Exchange (ETDEWEB)

    Duska, F.; Novak, J.; Vizda, J.; Kubicek, J.; Kafka, P.; Veverkova, O.

    1981-12-01

    In 9 dogs a transient myocardial ischemia was provoked using complete occlusion of the ramus interventricularis anterior of the left coronary artery. The occlusion was removed after 5, 10 or 15 min. Four hrs after removal of the occlusion a scan of the myocardium was carried out using sup(99m)Tc-labelled pyrophosphate. In 7 out of 9 dogs under study the scan was markedly positive, in 2 dogs negative. ECG demonstrated ischemic changes practically in all dogs; the changes became normal after removal of the occlusion, namely in 5 to 35 min. The histological examination of the tissue demonstrated in all 9 dogs only a slight impairment of the myocardium.

  7. Technetium-99m-pyrophosphate myocardial imaging in unstable angina

    International Nuclear Information System (INIS)

    Willerson, J.T.; Parkey, R.W.; Lewis, S.E.; Buja, L.M.; Bonte, F.J.

    1980-01-01

    The authors have found that approximately one third of patients with the syndrome of unstable angina pectoris have abnormal 99mTc-pyrophosphate myocardial scintigrams even in the absence of abnormal enzymes and electrocardiographic confirmation of the presence of acute myocardial necrosis. Thus, 99mTc-pyrophosphate myocardial imaging technique appears to represent a sensitive means to detect acute multicellular injury associated with the clinical syndrome of unstable angina pectoris even when cardiac enzymes are normal and the electrocardiogram does not definitively document the presence of acute myocardial necrosis. (Auth.)

  8. Radiochemicals used to scan the heart

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    Techniques for heart scanning using 201 Tl and /sup 99m/Tc pyrophosphate are discussed. Thallium-201, produced artificially in a cyclotron, concentrates in normal heart muscle but not in abnormal tissue. Technetium-99m is deposited in mitochondria of heart cells that are irreversibly damaged. The combined use of 201 Tl and /sup 99m/Tc makes it possible to identify regions of recent heart damage as well as older heart damage. Advantages of using 129 Cs for heart scanning are also discussed

  9. Analysis of one thousand liver scans carried out using technetium phytate

    Energy Technology Data Exchange (ETDEWEB)

    Pasquier, J; de Laforte, C; Roux, F; Bisset, J P; Paulin, R [Centre Hospitalier Universitaire de la Timone, 13 - Marseille (France)

    1977-10-01

    One thousand liver scans were carried out using technetium phytate. This soluble compound is transformed in the circulating blood into a colloid by chelation of serum calcium, thereby forming a macromolecular phytate of calcium and technetium. The presenting symptoms are compared with the isotopic findings. This microcolloid has the advantages common to all technetium tracers and, in addition, is easy to prepare and has the advantage of a distribution between the liver, spleen, and bone of the same type as that seen with colloidal gold 198 without the dosimetric problems associated with the latter. Although it has a level of hepatic fixation which is less than that of certain sulphide complexes of technetium it appears to provide a better reflection of the colloidopexic function of the liver.

  10. Analysis of one thousand liver scans carried out using technetium phytate

    International Nuclear Information System (INIS)

    Pasquier, J.; Laforte, C. de; Roux, F.; Bisset, J.P.; Paulin, R.

    1977-01-01

    One thousand liver scans were carried out using technetium phytate. This soluble compound is transformed in the circulating blood into a colloid by chelation of serum calcium, thereby forming a macromolecular phytate of calcium and technetium. The presenting symptoms are compared with the isotopic findings. This microcolloid has the advantages common to all technetium tracers and, in addition, is easy to prepare and has the advantage of a distribution between the liver, spleen and bone of the same type as that seen with colloidal gold 198 without the dosimetric problems associated with the latter. Although it has a level of hepatic fixation which is less than that of certain sulphide complexes of technetium it appears to provide a better reflection of the colloidopexic function of the liver [fr

  11. Significance of calcific valvular heart disease in /sup 99m/Tc pyrophosphate myocardial infarction scanning: radiographic, scintigraphic, and pathological correlation

    International Nuclear Information System (INIS)

    Jengo, J.A.; Mena, I.; Joe, S.H.; Criley, J.M.

    1977-01-01

    Technetium-99m pyrophosphate (PP/sub i/) is currently considered the best scanning agent for the diagnosis of acute myocardial infarction. False-positive scans have been reported in association with unstable angina, alcoholic cardiomyopathy, and ventricular aneurysms. In this study, 86 percent of patients (12/14) with either calcific aortic or mitral valvular heart disease had positive PP/sub i/ cardiac scintiscans and the location of the PP/sub i/ uptake was limited to the calcific valve in all (9/9) of the patients who underwent valve replacement surgery. Six patients with valvular disease without radiologic evidence of calcium had negative PP/sub i/ heart images. Three of these patients had surgical valve replacement, and in none was there increased uptake in the resected valve. Seventy-five percent of the patients with calcified aortic valves had localization of the PP/sub i/ activity to the area of the aortic valve, whereas 50 percent of the patients with calcified mitral valves showed a diffuse pattern of uptake on the cardiac image. In vitro demonstration of increased radioactivity in surgically removed cardiac valves warrants the conclusion that Tc-99m PP/sub i/ is taken up by calcified heart valves. We conclude that while PP/sub i/ heart scanning is a sensitive indicator of acute myocardial infarction, false-positive scans can occur in the presence of calcific valvular disease, due to localization of PP/sub i/ in the calcified portion of the valve

  12. Significance of calcific valvular heart disease in /sup 99m/Tc pyrophosphate myocardial infarction scanning: radiographic, scintigraphic, and pathological correlation

    Energy Technology Data Exchange (ETDEWEB)

    Jengo, J.A.; Mena, I.; Joe, S.H.; Criley, J.M.

    1977-08-01

    Technetium-99m pyrophosphate (PP/sub i/) is currently considered the best scanning agent for the diagnosis of acute myocardial infarction. False-positive scans have been reported in association with unstable angina, alcoholic cardiomyopathy, and ventricular aneurysms. In this study, 86 percent of patients (12/14) with either calcific aortic or mitral valvular heart disease had positive PP/sub i/ cardiac scintiscans and the location of the PP/sub i/ uptake was limited to the calcific valve in all (9/9) of the patients who underwent valve replacement surgery. Six patients with valvular disease without radiologic evidence of calcium had negative PP/sub i/ heart images. Three of these patients had surgical valve replacement, and in none was there increased uptake in the resected valve. Seventy-five percent of the patients with calcified aortic valves had localization of the PP/sub i/ activity to the area of the aortic valve, whereas 50 percent of the patients with calcified mitral valves showed a diffuse pattern of uptake on the cardiac image. In vitro demonstration of increased radioactivity in surgically removed cardiac valves warrants the conclusion that Tc-99m PP/sub i/ is taken up by calcified heart valves. We conclude that while PP/sub i/ heart scanning is a sensitive indicator of acute myocardial infarction, false-positive scans can occur in the presence of calcific valvular disease, due to localization of PP/sub i/ in the calcified portion of the valve.

  13. Sup(99m)Tc-Sn-pyrophosphate complex. A stable, lyophilized radiopharmaceutical for skeletal scanning

    Energy Technology Data Exchange (ETDEWEB)

    Cvoric, J; Jovanovic, V; Bzenic, J [Institut za Nuklearne Nauke Boris Kidric, Belgrade (Yugoslavia); Stefanovic, Lj; Selir, Z [Institute for Tuberculosis and Pectoral Diseases, Radioisotope Applications, Sremska Kamenica (Yugoslavia)

    1978-01-01

    After a systematic investigation of the different phosphate polymers, viz. hexametaphosphate, tripolyphosphate, meta- and diphosphonate, pyrophosphate (Na/sub 4/P/sub 2/O/sub 7/) was selected for sceletal scintigraphy. A procedure has been developed for obtaining a sup(99m)Tc-labelled Sn(II): PyP complex by addition of a sterile, apyrogenic pertechnetate solution from a sup(99m)Tc-generator to a lyophilized solution of Sn(II)-tetrasodium phosphate. ''Kit'' composition was determined on the basis of biodynamic data obtained when the Sn/pyrophosphate ratio, pH and other parameters were varied. In vivo distribution of different sup(99m)Tc-Sn-pyrophosphate complexes permitted the selection of the most suitable complex for sceletal scanning. The investigated complex is being successfully applied in human scintigraphy of bones in the Laboratory for Radioisotope Applications of the Institute for Tubercolosis and Pectoral Diseases in Sremska Kamenica.

  14. Complexes of technetium with pyrophosphate, etidronate, and medronate

    International Nuclear Information System (INIS)

    Russell, C.D.; Cash, A.G.

    1979-01-01

    The reduction of [ 99 Tc]pertechnetate was studied as a function of pH in complexing media of pyrophosphate, methylene diphosphonate (MDP), and ethane-1, hydroxy-1, and 1-diphosphonate (HEDP). Test (sampled d-c) and normal-pulse polarography were used to study the reduction of pertechnetate, and normal-pulse polarography (sweeping in the anodic direction) to study the reoxidation of the products. Below pH 6 TcO 4 - was reduced to Tc(III), which could be reoxidized to Tc(IV). Above pH 10, TcO 4 - was reduced in two steps to Tc(V) and Tc(IV), each of which could be reoxidized to TcO 4 - . Between pH 6 and 10 the results differed according to the ligand present. In pyrophosphate and MDP, TcO 4 - was reduced in two steps to Tc(IV) and Tc(III); Tc(III) could be reoxidized in two steps to Tc(IV) and TcO 4 - . In HEDP, on the other hand, TcO 4 - was reduced in two steps to Tc(V) and Tc(III), and could be reoxidized to Tc(IV) and TcO 4 - . Additional waves were observed; they apparently led to unstable products

  15. Technetium scanning in Kaposi's sarcoma and its simulators

    International Nuclear Information System (INIS)

    Gunnoe, R.; Kalivas, J.

    1982-01-01

    The clinical picture of ulcerated purple plaques on the legs often suggests several diagnoses: Kaposi's sarcoma, stasis dermatitis, atrophie blanche (livedoid vasculitis), and a poorly understood condition called acroangiodermatitis of Favre-Chaix (pseudo-Kaposi's sarcoma). Even the skin biopsy may not always be conclusive. We describe our experience with three patients with pseudo-Kaposi's sarcoma, one with true Kaposi's sarcoma and two with atrophie blanche. Clinical and histopathologic similarities among these three conditions pointed up the need for additional confirmatory studies, i.e., isotope scanning. The technetium scan was positive in both Kaposi's sarcoma and pseudo-Kaposi's sarcoma but negative in atrophie blanche

  16. Technetium /sup 99m/Tc macroaggregated albumin lung scans. Use in chronic childhood asthma

    International Nuclear Information System (INIS)

    Hyde, J.S.; Koch, D.F.; Isenberg, P.D.; Werner, P.

    1976-01-01

    Serial roentgenograms and technetium /sub 99m/Tc macroaggregated albumin lung scans were done simultaneously in 30 bronchodilator-dependent asthmatic children and young adults during both relative remission and attacks of status asthmaticus. When chest roentgenograms showed air trapping and increased peribronchial vascular markings associated with persistent perfusion defects, the children benefited from further laboratory studies and continuous comprehensive therapy. Serial scans provided information about underperfusion that was not discernible either by roentgenograms or by usual blood gas studies. Also, lung scans are easier to obtain in children with long-standing asthma than are detailed pulmonary tests. In our study, technetium /sup 99m/Tc macroaggregated albumin scans showed persistent regional perfusion defects in 20 children with chronic asthma during relative remission and exacerbations

  17. The abdominal technetium scan (a decade of experience)

    International Nuclear Information System (INIS)

    Cooney, D.R.; Duszynski, D.O.; Camboa, E.; Karp, M.P.; Jewett, T.C. Jr.

    1982-01-01

    Out of 270 children with gastrointestinal symptoms, the indications for technetium scanning were: gastrointestinal tract bleeding (165 patients), abdominal pain (99 patients) and a history of intussusception (6 patients). Thirty children had abnormal findings, while the remaining 240 patients had normal scans. Four of the 30 children with positive scans were not explored, while the others underwent laparotomy. Of the 26 operated patients, 12 (46%) had a Meckel's diverticulum. Nine patients (34%) had other pathologic lesions that were detected by the scan. Five had true false positives as no pathologic lesions were found. Of the 240 children with negative scans, 19 were eventually explored because of persistent symptoms or clinical findings. Two of these had a Meckel's diverticulum. Eleven had a negative exploration while six had other surgical lesions. Technitium scan should reliably detect around 80%-90% of Meckel's diverticula. It will also accurately exclude the diagnosis of Meckel's diverticulum in over 90% of patients

  18. Technetium 99mTc Pertechnetate Brain Scanning

    International Nuclear Information System (INIS)

    Rhee, Sang Min; Park, Jin Yung; Lee, Ahn Ki; Chung, Choo Il; Hong, Chang Gi; Rhee, Chong Heon; Koh, Chang Soon

    1968-01-01

    Technetium 99 mTc pertechnetate brain scanning were performed in 3 cases of head injury (2 chronic subdural hematomas and 1 acute epidural hematoma), 2 cases of brain abscess and 1 case of intracerebral hematoma associated with arteriovenous anomaly. In all the cases brain scintigrams showed 'hot areas.' Literatures on radioisotope scanning of intracranial lesions were briefly reviewed. With the improvement of radioisotope scanner and development of new radiopharmaceuticals brain scanning became a safe and useful screening test for diagnosis of intracranial lesions. Brain scanning can be easily performed even to a moribund patient without any discomfort and risk to the patient which are associated with cerebral angiography or pneumoencephalography. Brain scanning has been useful in diagnosis of brain tumor, brain abscess, subdural hematoma, and cerebral vascular diseases. In 80 to 90% of brain tumors positive scintigrams can be expected. Early studies were done with 203 Hg-Neohydrin or 131 I-serum albumin. With these agents, however, patients receive rather much radiation to the whole body and kidneys. In 1965 Harper introduced 99 mTc to reduce radiation dose to the patient and improve statistical variation in isotope scanning.

  19. Comparison of pyrophosphate and gluconate scan of dog hearts with experimental cardiomyopathy

    International Nuclear Information System (INIS)

    Duska, F.; Novak, J.; Kafka, P.; Kubicek, J.; Vizda, J.; Mazurova, Y.; Veverkova, O.

    1983-01-01

    High intravenous doses of theophylline with adrenalin were used to produce experimental cardiomyopathy in dogs. This damage was visualized scintigraphically using either sup(99m)Tc-pyrophosphate (10 dogs) or sup(99m)Tc-gluconate (another 10 dogs). Scintigraphic examinations using sup(99m)Tc-pyrophosphate were carried out 48 hours after the damage had developed: in two dogs the examination was negative, in two cases boundary, in 6 cases the scintigraphic finding was clearly positive. sup(99m)Tc-gluconate was used in the examination of 5 animals four hours after the damage had developed. In this case the scan was significantly positive in all cases. The gluconate scan was made 24 hours after damage, again in 5 dogs. Here the positive change was less explicit, in one case the finding was negative. Histological examination of the affected myocardium showed in all cases a very light damage, in many instances on the limit of resolution by light microscopy. The findings were always degenerative (dystrophic) changes and microcirculation disorders without any necrosis. The work showed that both studied radiopharmaceutical preparations are a very sensitive but nonspecific indicator of non-ischemic disorders of the myocardium. For sup(99m)Tc-gluconate this is an original finding. (author)

  20. Technetium complexation by macrocyclic compounds

    International Nuclear Information System (INIS)

    Li Fan Yu.

    1983-01-01

    Research in nuclear medicine are directed towards the labelling of biological molecules, however, sup(99m)Tc does not show sufficient affinity for these molecules. The aim of this study was to evaluate the ability of macrocyclic compounds to bind strongly technetium in order to be used as complexation intermediate. The reducing agents used were a stannous complex and sodium dithionite. Cryptates and polyesters are not good complexing agents. They form two complexes: a 2:1 sandwich complex or 3:2 and a 1:1 complex. Cyclams are good complexing agents for technetium their complexations strength was determined by competition with pyrophosphate, gluconate and DTPA. Using the method of ligand exchange, the oxidation state of technetium in the Tc-cyclam complex was IV or V. They are 1:1 cationic complexes, the complex charge is +1. The biodistribution in rats of labelling solutions containing (cyclam 14 ane N 4 ) C 12 H 25 shows a good urinary excretion without intoxication risks [fr

  1. Effect of methylprednisolone upon technetium-99m pyrophosphate assessment of myocardial necrosis in the canine countershock model

    International Nuclear Information System (INIS)

    Schneider, R.M.; Hayslett, J.P.; Downing, S.E.; Berger, H.J.; Donabedian, R.K.; Zaret, B.L.

    1977-01-01

    RRepeat DC countershock reproducibly results in myocardial necrosis in dogs. In this model, myocardial technetium-/sup 99m/ pyrophosphate (PYP) uptake correlates linearly with tissue creatine kinase depletion (r = -0.83). The effect of pretreatment with methylprednisolone (MP) was studied with PYP in 25 dogs. In myocardium damaged by countershock, 12 MP dogs had higher tissue radioactivity sample:normal (S:N) ratios than control (P < 0.05), suggesting increased tissue injury. However, by several other measures of tissue damage, the two groups did not differ. MP-elevated PYP S:N ratios were explained by reduced PYP activity in normal myocardium of MP dogs. Further experiments in 21 dogs revealed that renal PYP clearance, which correlated with glomerular filtration rate (GFR) as measured by creatinine clearance, was increased in MP dogs, resulting in accelerated urinary excretion of PYP (46.9 +- 3.6 vs 35.8 +- 2.4 percent injected dose in one hour, P < 0.01), and reduced blood PYP. Thus, MP does not modify countershock-induced myocardial injury. However, by increasing GFR, MP increased PYP excretion, resulting in lowered blood and normal zone myocardial PYP, thereby spuriously affecting myocardial PYP tissue uptake data

  2. Technetium {sup 99m}Tc Pertechnetate Brain Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Rhee, Sang Min; Park, Jin Yung; Lee, Ahn Ki; Chung, Choo Il; Hong, Chang Gi [Capital Army Hospital, ROKA, Seoul (Korea, Republic of); Rhee, Chong Heon; Koh, Chang Soon [Radiological Research Institute, Seoul (Korea, Republic of)

    1968-03-15

    Technetium {sup 99}mTc pertechnetate brain scanning were performed in 3 cases of head injury (2 chronic subdural hematomas and 1 acute epidural hematoma), 2 cases of brain abscess and 1 case of intracerebral hematoma associated with arteriovenous anomaly. In all the cases brain scintigrams showed 'hot areas.' Literatures on radioisotope scanning of intracranial lesions were briefly reviewed. With the improvement of radioisotope scanner and development of new radiopharmaceuticals brain scanning became a safe and useful screening test for diagnosis of intracranial lesions. Brain scanning can be easily performed even to a moribund patient without any discomfort and risk to the patient which are associated with cerebral angiography or pneumoencephalography. Brain scanning has been useful in diagnosis of brain tumor, brain abscess, subdural hematoma, and cerebral vascular diseases. In 80 to 90% of brain tumors positive scintigrams can be expected. Early studies were done with 203 Hg-Neohydrin or {sup 131}I-serum albumin. With these agents, however, patients receive rather much radiation to the whole body and kidneys. In 1965 Harper introduced {sup 99}mTc to reduce radiation dose to the patient and improve statistical variation in isotope scanning.

  3. Technetium phosphate bone scan in the diagnosis of septic arthritis in childhood

    International Nuclear Information System (INIS)

    Sundberg, S.B.; Savage, J.P.; Foster, B.K.

    1989-01-01

    The technetium phosphate bone scans of 106 children with suspected septic arthritis were reviewed to determine whether the bone scan can accurately differentiate septic from nonseptic arthropathy. Only 13% of children with proved septic arthritis had correct blind scan interpretation. The clinically adjusted interpretation did not identify septic arthritis in 30%. Septic arthritis was incorrectly identified in 32% of children with no evidence of septic arthritis. No statistically significant differences were noted between the scan findings in the septic and nonseptic groups and no scan findings correlated specifically with the presence or absence of joint sepsis

  4. Technetium-99m labeled radiodiagnostic agents for liver and bone marrow scanning and method of preparation

    International Nuclear Information System (INIS)

    Molinski, V.J.; Peacock, F.R.

    1977-01-01

    An improved technetium-99m labeled colloid and method of preparation comprising reducing technetium-99m with stannous oxalate and stabilizing with sodium phytate are described. This radiodiagnostic agent is useful in the scintigraphic examination of the reticuloendothelial system, particularly the liver. In addition, by autoclaving this product with saline, it becomes a superior bone marrow scanning agent

  5. Prognosis of ischemic heart disease based on pyrophosphate scan of myocardium

    Energy Technology Data Exchange (ETDEWEB)

    Duska, F [Karlova Univ., Hradec Kralove (Czechoslovakia). Lekarska Fakulta

    1982-11-01

    A brief survey is given of the present knowledge of the problems, based on literary data. Pyrophosphate myocardial scan is an important examination in establishing the diagnosis of acute myocardial infarction and some other myocardial diseases. Apart from this, it is of great importance in determining the prognosis. In the early phase of the disease, an apparently worse prognosis is found in patients with extensive lesion, and in those with an infarction intensively accumulating the radiopharmaceutical. In a certain number of infarctions, scintigraphic examination is positive over several months; usually the radiopharmaceutical disappears within two weeks. Patients with long-persisting positivity have a markedly worse prognosis. On the basis of early and late heart scan, it is thus possible to estimate the future fate of patients w+th ischemic heart disease. Large and long-persisting lesions serve as a warning for the physician.

  6. Quantification of myocardial infarct size by technetium-99m pyrophosphate single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Hiromichi; Fukuyama, Takaya; Aoki, Makoto; Inou, Tetsuji; Ashihara, Toshiaki; Nabeyama, Shyohzou; Yamamoto, Yuhsuke

    1989-04-01

    Myocardial infarct size in 41 patients with the first attack of acute transmural myocardial infarction (MI) was assessed by technetium-99m pyrophosphate single photon emission computed tomography (/sup 99m/TcPYP-SPECT). A ratio of the number of voxels of /sup 99m/TcPYP uptake into the infarct area to that into the thorax was calculated as a parameter of MI size. The ratio was positively correlated with both peak CPK activity (r=0.53, p<0.005, n=24) and extent score in /sup 201/Tl-SPECT (r=0.70, p<0.005, n=14) significantly in patients with anterior MI but not in patients with inferior MI. There was also significant negative correlation between the ratio and the left ventricular ejection fraction (LVEF) measured by RI angiography in both acute (r=-0.67, p<0.005, n=18) and chronic (r=-0.75, p<0.005, n=25) phases in patients with anterior MI. Recovery in LVEF at chronic phase was noted in patients with small anterior MI but not with large anterior MI. Eight of 14 patients with inferior MI had right ventricular MI, that might have affected evaluation of MI size and resulted in no correlation between variables. It was suggested that /sup 99m/TcPYP-SPECT was a useful method to evaluate MI size and to predict prognosis of cardiac function in patients with anterior MI but not in patients with inferior MI. (author).

  7. Myocardial scintigraphy using pyrophosphate-technetium 99m. 367 cases

    Energy Technology Data Exchange (ETDEWEB)

    Degeorges, M; Roucayrol, J C; Sol, C; Comet, M; Vassilopoulos, J [Hopital Cochin, 75 - Paris (France)

    1977-04-30

    Pyrophosphate-sup(99m)Tc injected intravenously, is almost invariably fixed in the infarcted zone in transmural infarctions less than 8 days old. Fixation occurs in only 2/3 of cases of rudimentary infarction. The degree of fixation is more or less proportional to the size of the peak of creatine phosphokinase. After the 8th day following infarction, fixation is slight or nil. It is inconstant in pre-infarction syndrome or simple angina. This examination complements clinical, electrocardiographic and enzyme findings, in particular in the case of difficult diagnosis.

  8. Usefulness of scintigraphy with Tc-99m labelled pyrophosphate in the diagnosis of acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Zolna, J; Strzelecki, A; Bartoszewski, A; Kardaszewicz, P; Salamon, A; Waligorski, M

    1982-01-01

    In 32 patients with transmural myocardial infarction scintigraphy was done using technetium-99m pyrophosphate as a marker. The test was performed between 4 and 7 day after infarction onset. In the group of 18 patients with anterior wall infarction in 2 cases no cumulation of the radioisotope was observed while in 14 cases the absorption of pyro-phosphate estimated to correspond to grade 2 or 3 in Parkey's scoring system was observed. In the group of 14 patients with inferior wall infarction in 4 cases pyrophosphate was not absorbed or only in a small degree. In the remaining patients radioactivity absorption was estimated to correspond to Parkey's grades 2 or 3. In both groups the radioacti-vity was absorbed more intensely in cases with high creatine phosphoki-nase values.

  9. Clinical usefulness of technetium-99m pyrophosphate and Tl-201 myocardial imaging for the estimation of myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Akio; Sato, Akihiko; Miyakoda, Hiroyuki; Watanabe, Toshiya; Itatsu, Hidetaka; Ueda, Osamu; Sakurai, Kuniteru; Kawai, Naoki; Sotobata, Iwao

    1985-04-01

    A correlative study was performed between the infarct size estimated by either technetium-99 pyrophosphate (Tc-PYP) or Tl-201 myocardial imaging, and the cumulative total creatinine phosphokinase activity (..sigma..CPK) or left ventricular ejection fraction (LVEF) in 40 patients with acute myocardial infarction. Tc-PYP infarct area (TcIA) and mean Tl-201 uptake ratio (MUR) were calculated as indices of myocardial infarct size. LVEF was evaluated by first pass method using Tc-PYP in the acute phase of myocardial infraction. In 23 patients with anterior myocardial infarction, a significant correlation was shown between either TcIA or anterior-wall MUR and ..sigma..CPK (r=0.81 and r=-0.69, respectively) and also between either TcIA or anterior-wall MUR and LVEF (r=-0.84 and r=0.80, respectively). In 17 patients with inferior myocardial infarction without additional involvement of right ventricular wall, inferior-wall MUR correlated with ..sigma..CPK (r=-0.74). No statically significant correlation was shown between TcIA and ..sigma..CPK, and also between either TcIA or inferior-wall MUR and LVEF. In conclusion, the infarct size estimated with Tc-PYP or Tl-201 myocardial imaging could be a useful clinical indicator of the severity of acute myocardial infarction especially in anterior wall. (author).

  10. Scintigraphic visualization of myocardial infarcts in baboons using thallium-201 and technetium-99m pyrophosphate

    Energy Technology Data Exchange (ETDEWEB)

    Frick, M P; Ponto, R A; Pyle, R B; Yasmineh, W G; Loken, M K

    1978-01-01

    Four baboons with myocardial infarcts were evaluated using thallium-201 for myocardial imaging and /sup 99m/Tc pyrophosphate for infarct visualization. Scintiphotographic findings were compared with the size of myocardial infarcts calculated from measurements of the activity of MB isoenzymes of creatine kinase (CK-MB) in serum and in the myocardium at autopsy, as described by Sobel's method. Lack of thallium-201 accumulation was noted in left ventricular infarcts of 3 of the 4 baboons. These same areas localized /sup 99m/Tc pyrophosphate administered 24 to 30 h after infarction.

  11. Technetium 99m methylene diphosphonate bone scanning in osteoarthritic hands

    International Nuclear Information System (INIS)

    Buckland-Wright, J.C.; Lynch, J.A.; Macfarlane, D.G.; Homoeopathic Hospital, Tunbridge; Fogelman, I.; Emery, P.

    1991-01-01

    In this prospective study, the radiological features characteristic of osteoarthritis of the hand were compared with the radionuclide bone scan images. A total of 32 patients was assessed at 6-monthly intervals for 18 months. Microfocal radiographs were taken at each visit. The high magnification and resolution of this technique permitted direct measurement of joint space width, subchondral sclerosis, osteophyte number and area and juxta-articular radiolucency area for each joint in the hand. Four-hour technetium 99m methylene diphosphonate bone scans were taken at 0 and 12 months and the activity of tracer uptake at each joint scored. The latter was compared with each X-radiographic feature at every visit and the changes between visits analysed. The scan scores did not correlate with any of the X-radiographic features other than osteophyte size. During the study the size of growing and remodelling osteophytes increased significantly at joints with raised or increased isotope uptake. (orig.)

  12. Technetium 99m methylene diphosphonate bone scanning in osteoarthritic hands

    Energy Technology Data Exchange (ETDEWEB)

    Buckland-Wright, J.C.; Lynch, J.A. (United Medical and Dental Schools of Guy' s and Saint Thomas' , London (UK). Dept. of Anatomy); Macfarlane, D.G. (United Medical and Dental Schools of Guy' s and Saint Thomas' , London (UK). Dept. of Anatomy Homoeopathic Hospital, Tunbridge (UK). Dept. of Rheumatology); Fogelman, I. (United Medical and Dental Schools of Guy' s and Saint Thomas' , London (UK). Dept. of Nuclear Medicine); Emery, P. (United Medical and Dental Schools of Guy' s and Saint Thomas' , London (UK). Dept. of Rheumatology)

    1991-01-01

    In this prospective study, the radiological features characteristic of osteoarthritis of the hand were compared with the radionuclide bone scan images. A total of 32 patients was assessed at 6-monthly intervals for 18 months. Microfocal radiographs were taken at each visit. The high magnification and resolution of this technique permitted direct measurement of joint space width, subchondral sclerosis, osteophyte number and area and juxta-articular radiolucency area for each joint in the hand. Four-hour technetium 99m methylene diphosphonate bone scans were taken at 0 and 12 months and the activity of tracer uptake at each joint scored. The latter was compared with each X-radiographic feature at every visit and the changes between visits analysed. The scan scores did not correlate with any of the X-radiographic features other than osteophyte size. During the study the size of growing and remodelling osteophytes increased significantly at joints with raised or increased isotope uptake. (orig.).

  13. High-risk angina patient: identification by clinical features, hospital course, electrocardiography, and technetium-99m stannous pyrophosphate scintigraphy

    International Nuclear Information System (INIS)

    Olson, H.G.; Lyons, K.P.; Aronow, W.S.; Stinson, P.J.; Kuperus, J.; Waters, H.J.

    1981-01-01

    We evaluated 193 consecutive unstable angina patients by clinical features, hospital course and electrocardiography. All patients were managed medically. Of the 193 patients, 150 (78%) had a technetium-99m pyrophosphate (Tc-PYP) myocardial scintigram after hospitalization. Of these, 49 (33%) had positive scintigrams. At a follow-up of 24.9 +- 10.8 months after hospitalization, 16 of 49 patients (33%) with positive scintigrams died from cardiac causes, compared with six of 101 patients (6%) with negative scintigrams (p < 0.001). Of 49 patients with positive scintigrams, 11 (22%) had had nonfatal myocardial infarction at follow-up, compared with seven of 101 patients (7%) with negative scintigrams (p < 0.01). Age, duration of clinical coronary artery disease, continuing angina during hospitalization, ischemic ECG, cardiomegaly and a history of heart failure also correlated with cardiac death at follow-up. Ischemic ECG and a history of angina with a crescendo pattern also correlated with nonfatal infarction at follow-up. Patients with continuing angina, an ischemic ECG and a positive scintigram constituted a high-risk unstable angina subgroup, with a survival rate of 58% at 6 months, 47% at 12 months and 42% at 24 and 36 months. We conclude that the assessment of clinical features, hospital course, ECG and Tc-PYP scintigraphy may be useful in identifying high-risk unstable angina patients

  14. High-risk angina patient. Identification by clinical features, hospital course, electrocardiography and technetium-99m stannous pyrophosphate scintigraphy

    International Nuclear Information System (INIS)

    Olson, H.G.; Lyons, K.P.; Aronow, W.S.; Stinson, P.J.; Kuperus, J.; Waters, H.J.

    1981-01-01

    We evaluated 193 consecutive unstable angina patients by clinical features, hospital course and electrocardiography. All patients were managed medically. Of the 193 patients, 150 (78%) had a technetium-99m pyrophosphate (Tc-PYP) myocardial scintigram after hospitalization. Of these, 49 (33%) had positive scintigrams. At a follow-up of 24.9 +/- 10.8 months after hospitalization, 16 of 49 patients (33%) with positive scintigrams died from cardiac causes, compared with six of 101 patients (6%) with negative scintigrams (p less than 0.001). Of 49 patients with positive scintigrams, 11 (22%) had had nonfatal myocardial infarction at follow-up, compared with seven of 101 patients (7%) with negative scintigrams (p less than 0.01). Age, duration of clinical coronary artery disease, continuing angina during hospitalization, ischemic ECG, cardiomegaly and a history of heart failure also correlated with cardiac death at follow-up. Ischemic ECG and a history of angina with a crescendo pattern also correlated with nonfatal infarction at follow-up. Patients with continuing angina, an ischemic ECG and a positive scintigram constituted a high-risk unstable angina subgroup with a survival rate of 58% at 6 months, 47% at 12 months and 42% at 24 and 36 months. We conclude that the assessment of clinical features, hospital course, ECG and Tc-PYP scintigraphy may be useful in identifying high-risk unstable angina patients

  15. Increased incidence and clinical correlation of persistently abnormal technetium pyrophosphate myocardial scintigrams following acute myocardial infarction in patients with diabetes mellitus

    International Nuclear Information System (INIS)

    Nicod, P.; Lewis, S.E.; Corbett, J.C.; Buja, L.M.; Henderson, G.; Raskin, P.; Rude, R.E.; Willerson, J.T.

    1982-01-01

    Persistently abnormal /sup 99m/Tc stannous pyrophosphate myocardial scintigrams (PPi+) appear to be associated with a relatively poor prognosis after acute myocardial infarction (AMI). To assess the incidence and implications of PPi+, we performed a retrospective analysis in 29 patients with and 25 patients without diabetes mellitus who had abnormal myocardial scintigrams within 4 days of AMI and who had follow-up scintigrams at least 3 months after hospital discharge. There were no significant differences between patients with and without diabetes as regards age, incidence of transmural or nontransmural AMI, or degree of left ventricular dysfunction after AMI. Persistently abnormal PPi+ occurred more commonly in patients with diabetes than in nondiabetic patients (18 of 29, 62%, compared to 3 of 25, 12%; p less than 0.001). Patients with chronic PPi+ had more frequent cardiac complications following hospital discharge (p less than 0.005) including death, recurrent AMI, unstable angina, and intractable congestive heart failure. Postmortem analysis in two patients with diabetes and chronic PPi+ revealed marked myocytolysis. Thus, patients with diabetes mellitus have an increased incidence of post-AMI persistently abnormal technetium (PPi+) scintigrams and relatively poor prognosis following myocardial infarction

  16. Photoaffinity labeling of undecaprenyl pyrophosphate synthetase with a farnesyl pyrophosphate analogue

    International Nuclear Information System (INIS)

    Baba, T.; Muth, J.; Allen, C.M.

    1985-01-01

    The prenyl transferase undecaprenyl pyrophosphate synthetase was partially purified from the cytosolic fraction of Escherichia coli. Its enzymic products were characterized as a family of cis-polyprenyl phosphates, which ranged in carbon number from C55 to C25. The enzyme is constituted of two subunits of approximately 30,000 molecular weight. A radiolabeled photolabile analogue of t,t-farnesyl pyrophosphate, [ 3 H]2-diazo-3-trifluoropropionyloxy geranyl pyrophosphate, was shown to label Lactobacillus plantarum and E. coli undecaprenyl pyrophosphate synthetase on UV irradiation in the presence of isopentenyl pyrophosphate and divalent cations. The only labeled polypeptide migrated on electrophoresis in a sodium dodecyl sulfate-polyacrylamide gel at a molecular weight of approximately 30,000. No protein was radiolabeled when the natural substrate, t,t-farnesyl pyrophosphate was included in the irradiation mixture. Irradiation in the presence of MgCl 2 without isopentenyl pyrophosphate gave less labeling of the polypeptide. Irradiation with only isopentenyl pyrophosphate gave little labeling of the polypeptide. When the enzyme was irradiated with 3H-photoprobe, [ 14 C]isopentenyl pyrophosphate, and MgCl 2 , the labeled polypeptide gave a ratio of 14 C/ 3 H that indicated the product must also bind to the enzyme on irradiation. These results demonstrate the ability to radiolabel the allylic pyrophosphate binding site and possibly product binding site of undecaprenyl pyrophosphate synthetase by a process which is favored when both cosubstrate and divalent cations are present

  17. Effect of EHDP on calcium accumulation and technetium-99m pyrophosphate uptake in experimental myocardial infarction

    International Nuclear Information System (INIS)

    Buja, L.M.; Tofe, A.J.; Parkey, R.W.; Francis, M.D.; Lewis, S.E.; Kulkarni, P.V.; Bonte, F.J.; Willerson, J.T.

    1981-01-01

    Ethane-l-hydroxy-1,1-diphosphonate (EHDP) inhibits bone mineral growth. This study was performed to test the hypothesis that EHDP would interfere with the process of calcium uptake and deposition in evolving myocardial infarction and thereby influence other parameters, including technetium-99m pyrophosphate (Tc-99m PYP) uptake and scintigraphic visualization of the infarcts. Permanent occlusion of the left anterior descending coronary artery (LAD) was produced in beagles. In seven dogs, serum EHDP was maintained at 10-15 μg/ml for 24 hours by continuous i.v. infusion, and seven control dogs were infused with saline. The Tc-99m PYP was infected 2 hours before sacrifice. EHDP-treated dogs showed a mild decrease (20%) in mean calcium content of infarcted myocardium (102.4 +/- 6.4 μg [+/- SEM] per gram wet weight [n = 51] vs 126.7 +/- 9.5 [n = 49] [p -3 ] [n = 46] vs 28.9 +/- 4.3 [n = 46] [p < 0.005]) and a marked decrease (65%) in infarct-to-normal ratio (6.1 +/- 0.9 [n = 6] vs 15.9 +/- 3.7 [n = 6] [p < 0.05]). Positive relationships were demonstrated between myocardial Tc-99m PYP and calcium levels in the EHDP-treated dogs (r = 0.69) and the control dogs (r = 0.77). Infarct size and regional myocardial blood flow changes were similar in the EHDP-treated and control dogs. The average grade (0-4+) of the Tc-99m PYP myocardial scintigrams for infarcts greater than 3.5 g was 2.4 +/- 0.2 for control dogs and 1.1 +/- 0.4 for EHDP-treated dogs (p < 0.05). Thus, EHDP infusion at the dose tested produced a mild decrease in calcium accumulation in canine infarcts; however, it produced a greater reduction in Tc-99m PYP uptake in the infarcts

  18. Validation of measurements of Fourier phase and amplitude analysis of technetium99 gated cardiac scans using artificial hearts

    International Nuclear Information System (INIS)

    Yiannikas, J.; Takatani, S.; MacIntyre, W.J.; Underwood, D.A.; Cook, S.A.; Go, R.T.; Napoli, C.; Nose, Y.

    1982-01-01

    The use of artificial hearts, developed for total heart replacement programs, allows assessment of the accuracy of measuring the first Fourier component phase and amplitude when applied to gated cardiac technetium 99 scans. In the extreme example of asynchrony of ventricular contraction in coronary artery disease that of ventricular aneurysms, the first Fourier component measurements of amplitude were highly correlated to volume increases suggesting that the calculated amplitude accurately reflects volume changes. The calculated asynchrony using Fourier analysis of the gated technetium 99 studies of two artificial hearts was highly accurate when compared to the predetermined calculation of phase angle difference and hence degree of asynchrony. The studies suggest that measurement of phase and amplitude using the first Fourier component of time-activity waves of gated cardiac technetium 99 studies accurately measure degree of asynchrony and volume changes respectively

  19. Lutetium pyrophosphates

    International Nuclear Information System (INIS)

    Dzhabishvili, N.A.; Davitashvili, E.G.; Orlovskij, V.P.; Kargareteli, L.N.

    1986-01-01

    Reaction between lutetium nitrate and pyrophosphates of sodium, potassium and ammonium in aqueous solution is studied, using the method of residual concentrations. New compounds are isolated, their composition and physicochemical properties are considered. Data on solubility in the systems at 25 deg C are given. All the hydrate pyrophosphates are roentgenoamorphous, they are crystallized only when heated. Thermal decomposition of lutetium pyrophosphate is investigated

  20. Role of technetium-99m planar bone scanning in the evaluation of low back pain

    International Nuclear Information System (INIS)

    Valdez, D.C.; Johnson, R.G.

    1994-01-01

    The records of 1018 patients with low back pain in a tertiary spine referral practice were reviewed. One hundred thirty-nine out of 1018 (13.6%) underwent technetium-99m planar bone scannings as part of their investigation. Seventy-three out of 139 scans (52%) showed increased uptake in some area, but only 27 out of 139 (19.4%) showed increased uptake specifically in the low back. Scans consistently yielded no findings with reference to the back when the prescan diagnosis was spinal stenosis, lumbar pain syndrome, herniated nucleus pulposus, or postlaminectomy syndrome. Some scans gave positive findings in patients with a diagnosis of degenerative disc disease, pseudoarthrosis, spondylolisthesis, fracture, infection, metabolic disorder, or tumor. Positive scans were generally obtained early after presentation (within 3 months) and negative scans obtained later (after 6 months), suggesting that clinical suspicion is still the main indication for early scanning. Planar bone scanning was helpful in both diagnosis and therapeutic decision-making in many conditions. (orig.)

  1. Evaluating microvascular obstruction after acute myocardial infarction using cardiac magnetic resonance imaging and 201-thallium and 99m-technetium pyrophosphate scintigraphy

    International Nuclear Information System (INIS)

    Onishi, Takayuki; Kobayashi, Isshi; Onishi, Yuko; Kawashima, Tomoyuki; Muramoto, Hirotaka; Nakamura, Hiroaki; Nagata, Yasutoshi; Umezawa, Shigeo; Niwa, Akihiro

    2010-01-01

    Few studies have compared the ability of cardiac magnetic resonance (CMR) with that of scintigraphy using 201-thallium (201-Tl) and 99m-technetium pyrophosphate (99m-Tc PYP) to evaluate microvascular obstructions (MOs). In the present study the relationship between the scintigraphic and CMR characteristics of MOs after acute myocardial infarction (MI) was examined. The 14 patients (age 69±8 years, 11 males) underwent 201-Tl/99m-Tc PYP single photon emission computed tomography (SPECT) 7±3 days, initial CMR 16±12 days, and follow-up CMR 193±20 days after a reperfused first acute MI. Each image was analyzed using a 17-segment model. Segmental extent of delayed enhancement (DE), wall motion (WM) and degree of 201-Tl uptake were scored in 238 segments. Of 91 MI segments, MO was recognized in 22 (25%) segments on CMR. WM was significantly better in proportion to 201-Tl uptake (P=0.01) in MO segments. All 8 MO segments with WM improvement at follow-up had 99m-Tc PYP uptake, although only 3 (21%) of 14 MO segments that did not show WM improvement at follow-up had 99m-Tc PYP uptake (P=0.001). 99m-Tc PYP and 201-Tl scintigraphy have the potential to predict WM status and improvement of the MO region after reperfused acute MI. (author)

  2. Technetium and technetium alloys

    International Nuclear Information System (INIS)

    Ijdo, W.L.

    1993-10-01

    This report presents the results of a literature survey on technetium and technetium alloys. The literature has been searched through 1993. The survey was focused on technetium and (binary cubic) technetium alloys, but other important information on technetium has not been omitted from this survey. This report has been written with the aim to collect more information about phase systems which could be of importance in the transmutation process by neutrons of technetium. With the information presented in this report, it should be possible to select a suitable technetium alloy for further investigation regarding to the transmutation process. (orig.)

  3. Increased technetium uptake is not equivalent to muscle necrosis: scintigraphic, morphological and intramuscular pressure analyses of sore muscles after exercise

    Science.gov (United States)

    Crenshaw, A. G.; Friden, J.; Hargens, A. R.; Lang, G. H.; Thornell, L. E.

    1993-01-01

    A scintigraphic technique employing technetium pyrophosphate uptake was used to identify the area of skeletal muscle damage in the lower leg of four runners 24 h after an ultramarathon footrace (160 km). Most of the race had been run downhill which incorporated an extensive amount of eccentric work. Soreness was diffuse throughout the posterior region of the lower leg. In order to interpret what increased technetium uptake reflects and to express extreme endurance related damages, a biopsy was taken from the 3-D position of abnormal uptake. In addition, intramuscular pressures were determined in the deep posterior compartment. Scintigraphs revealed increased technetium pyrophosphate uptake in the medial portion of the gastrocnemius muscle. For 3698 fibres analysed, 33 fibres (1%) were necrotic, while a few other fibres were either atrophic or irregular shaped. A cluster of necrotic fibres occurred at the fascicular periphery for one subject and fibre type grouping occurred for another. Ultrastructural analysis revealed Z-line streaming near many capillaries and variously altered subsarcolemmal mitochondria including some with paracrystalline inclusions. The majority of the capillaries included thickened and irregular shaped endothelial cells. Intramuscular pressures of the deep posterior compartment were slightly elevated (12-15 mmHg) for three of the four subjects. Increased technetium uptake following extreme endurance running does not just reflect muscle necrosis but also subtle fibre abnormalities. Collectively, these pathological findings are attributed to relative ischaemia occurring during the race and during pre-race training, whereas, intramuscular pressure elevations associated with muscle soreness are attributed to mechanical stress caused by extensive eccentric work during the race.

  4. Calcium Pyrophosphate Deposition (CPPD)

    Science.gov (United States)

    ... Patient / Caregiver Diseases & Conditions Calcium Pyrophosphate Deposition (CPPD) Calcium Pyrophosphate Deposition (CPPD) Fast Facts The risk of ... young people, too. Proper diagnosis depends on detecting calcium pyrophosphate crystals in the fluid of an affected ...

  5. Experience based on 60 observations of scintigraphic bone exploration using pyrophosphates

    International Nuclear Information System (INIS)

    Mienville, J.-C.

    1975-01-01

    5 to 15 millicuries of technetium 99m-labelled pyrophosphates are injected intraveinously. 3 to 5 hours later, when the blood activity has dropped, the bone uptake is sufficient to give a good scintigraphic image of the skeleton. The skeleton may be explored one segment at a time, using a scanning scintigraph or a scintillation camera, or the whole skeleton front and back may be examined much more quickly with a 'whole-body' device. A study of 60 observations shows the large number of hyperfixations revealed by isotopic explorations in rheumatological diseases. A hyperfixation was observed in almost all bone localities of osteophilic cancers, osteonecrosis, Paget's disease, infections osteo-arthritis and algoneurodystrophy. On the other hand the isotopic test was found to be negative or inefficient in arthroses, osteoporosis and local bone manifestations of Kahler's or Hodgkin's disease. Finally inflammatory arthritis was detectable by scintigraphy in about half the cases studied. In reality a hyperfixation reflects a local rise in the metabolic activity of the bone at the moment of the examination. As a result the scintigraphic images lack specificity. This factor must therefore be accounted for in the patient's records and isotopic results compared with those of clinical and para-clinical examinations [fr

  6. Infarct size in patients with acute myocardial infarction estimated by emission computed tomography with technetium-99m pyrophosphate. Relation to creatine phosphokinase release

    Energy Technology Data Exchange (ETDEWEB)

    Maruyama, Jun-ichi; Onodera, Sokichi; Imura, Suguru; Marutani, Yoshiaki; Takahori, Takashi; Nasuhara, Koh-ichi

    1986-09-01

    To evaluate the usefulness of single photon emission computed tomography (SPECT) with technetium-99m-pyrophosphate (/sup 99m/Tc-PYP) for estimating infarct size, we compared SPECT data with maximum creatine phosphokinase values. Background threshold was established in a series of phantom experiments. When a 40 % cut-off was applied, the SPECT data most closely approximated actual phantom volumes. Therefore, the 40 % cut-off level was used in the present study. In 10 patients with acute myocardial infarction, planar /sup 99m/Tc-PYP myocardial scintigraphy and SPECT using a rotating gamma camera were performed two days after the initial myocardial infarction episode. The maximum creatine phosphokinase value (CPKmax) was also measured repeatedly following the episode. When the infarct size measured by SPECT using transaxial images and calculated by the pixel counts, it correlated very closely with CPKmax (r = 0.94). Most studies so far have reported that the CPKmax level reflects infarct size. We conclude that the infarct size as measured by /sup 99m/Tc-PYP SPECT closely approximates the actual infarct size, and that this method is useful to determine the severity of infarcts clinically. Among the 10 patients in this series, three of five with infarcts greater than 60 ml died of pump failure. Therefore, we may be able to predict prognosis after accumulating more such cases and improving the methodology.

  7. Change perspective to increase diagnostic accuracy of ultrasonography in calcium pyrophosphate dihydrate deposition disease! A new approach: the axial scan of the meniscus

    Directory of Open Access Journals (Sweden)

    G. Filippou

    2015-03-01

    Full Text Available Ultrasonography (US is a relevant tool in the study of calcium pyrophosphate dihydrate (CPP deposition disease. However, differential diagnosis of hyperechoic deposits within the fibrocartilage can be difficult; moreover, US study is limited by the need of an adequate acoustic window. We describe a US scanning technique that offers a new viewpoint in the study of knee meniscal structure: a longitudinal scan performed according to the long axis of meniscus. This technique proves to be particularly useful for the identification of CPP deposition, but could also improve the US diagnostic utility and accuracy in other meniscal pathologies.

  8. Clinical application of calculated split renal volume using computed tomography-based renal volumetry after partial nephrectomy: Correlation with technetium-99m dimercaptosuccinic acid renal scan data.

    Science.gov (United States)

    Lee, Chan Ho; Park, Young Joo; Ku, Ja Yoon; Ha, Hong Koo

    2017-06-01

    To evaluate the clinical application of computed tomography-based measurement of renal cortical volume and split renal volume as a single tool to assess the anatomy and renal function in patients with renal tumors before and after partial nephrectomy, and to compare the findings with technetium-99m dimercaptosuccinic acid renal scan. The data of 51 patients with a unilateral renal tumor managed by partial nephrectomy were retrospectively analyzed. The renal cortical volume of tumor-bearing and contralateral kidneys was measured using ImageJ software. Split estimated glomerular filtration rate and split renal volume calculated using this renal cortical volume were compared with the split renal function measured with technetium-99m dimercaptosuccinic acid renal scan. A strong correlation between split renal function and split renal volume of the tumor-bearing kidney was observed before and after surgery (r = 0.89, P volumetry had a strong correlation with the split renal function measured using technetium-99m dimercaptosuccinic acid renal scan. Computed tomography-based split renal volume measurement before and after partial nephrectomy can be used as a single modality for anatomical and functional assessment of the tumor-bearing kidney. © 2017 The Japanese Urological Association.

  9. 99mTc bone scanning agents preparation and chemical analysis of Tc(Sn)pyrophosphate, Tc(Sn)MDP and Tc(Sn)HMDP

    International Nuclear Information System (INIS)

    Kroesbergen, J.

    1986-01-01

    This thesis describes a comparison of the preparation, composition and properties of three bone scanning agents: 99m Tc(Sn)pyrophosphate, 99m Tc(Sn)MDP and 99m Tc(Sn)HMDP. This study has been performed for two reasons: First to investigate the preparation and composition of the radiopharmaceuticals as a function of experimental conditions. Together with previously reported results for 99m Tc(Sn)EHDP, obtained in a similar way, this enables to use well-defined preparations of the bone scanning agents. Secondly to gain an insight in the mechanism in which the agents behave 'in vivo'. Because the 'in vivo' process is too complicated to study directly, it seemed more appropriate to perform 'in vitro' investigations as simplifications of the 'in vivo' situation. 304 refs.; 26 figs.; 31 tabs

  10. Post-traumatic avascular necrosis of the femoral head predicted by preoperative technetium-99m antimony-colloid scan: an experimental and clinical study

    International Nuclear Information System (INIS)

    Turner, J.H.

    1983-01-01

    Technetium-99m antimony colloid was used to visualize the bone marrow of the head of the femur within twenty-four hours after interruption of the blood supply by subcapital osteotomy and section of the ligamentum teres in thirteen rabbits and within twenty-four hours after a subcapital fracture in thirty patients. Of the rabbits, all showed loss of marrow radioactivity over the affected femoral head. Bone-imaging with technetium-99m methylene diphosphonate, in contrast, failed to demonstrate any abnormality in the avascular head of the femur for as long as forty-eight hours after osteotomy. This difference between the marrow scan and the bone scan was attributed to earlier loss of function in the marrow cells than in the osteocytes. The thirty patients who had a preoperative scan within twenty-four hours after sustaining a subcapital fracture were treated by internal fixation with a Richards screw and plate and were followed for as long as two years, or until the patient died or radiographs showed evidence of avascular necrosis. The preoperative technetium-99m antimony-colloid activity in the head of the fractured femur was normal in sixteen patients and absent in fourteen; two of the fourteen had no activity in either hip, which precluded assessment of the fractured hip in these patients. In fifteen of the sixteen hips, preservation of the uptake in the marrow of the head of the fractured femur preoperatively predicted normal healing. Late segmental collapse developed in the remaining hip. In eleven of the twelve patients who had loss of marrow activity in the femoral head preoperatively, avascular necrosis developed within two years

  11. Technetium-Iron Complex. Radiopharmaceutical for Renal Scanning and Function Studies

    Energy Technology Data Exchange (ETDEWEB)

    Aquino, J. A.; Cunningham, R. M. [Victoria General Hospital and Dalhousie Medical School, Halifax, NS (Canada)

    1969-05-15

    A preliminary report on the use of a technetium-iron complex as a radiopharmaceutical in the evaluation of kidney function as well as renal scanning is presented. The first part considers the {sup 99m}Tc iron complex as an agent to determine the kidney function. This is correlated with the conventional {sup 131}I Hippuran renogram as well as the mercury accumulative test. The second part describes the use of the {sup 99m}Tc iron complex as a renal scanning agent; again it is compared with {sup 197}Hg Neohydrin. The availability of the Anger gamma camera, along with {sup 99m}Tc and its favourable characteristics have encouraged further search for better preparations. Among these is the {sup 99m}Tc iron complex. The authors' technique of preparation is described. Although the pertechnetate ion is not very active chemically in combining with other compounds, it is readily reduced to more reactive lower valence states. Such alterations of chemical form produce changes in biologic localization of {sup 99m}Tc. After the intravenous injection of {sup 99m}Tc as pertechnetate, it is rapidly localized in the stomach, urinary bladder, thyroid, and salivary glands. Excretion during the first 24 h occurs largely through the urine. Harper et al. have shown that the {sup 99m}Tc iron complex is rapidly excreted through the urine. The initial disappearance from the plasma is so very rapid that 50% or more has usually left the blood in 3-5 min. Part of the 5'irnTc is fixed in the kidney which constitutes half of what is retained in the body. Our technique consists of obtaining the conventional {sup 131}I Hippuran renogram. This is followed by the injection of {sup 99m}Tc iron complex. The two renograms obtained, using the two agents, are correlated along with other diagnostic tests. Since the {sup 99m}Tc iron complex used for doing the renogram can be used in scanning the kidney, both kidneys are scanned using the Anger gamma camera. Comparative scans are done with the use of {sup

  12. Technetium-99m pyrophosphate myocardial scintigraphy in the diagnosis of acute rheumatic carditis

    International Nuclear Information System (INIS)

    Malhotra, A.; Radhakrishnan, S.; Reddy, K.S.; Gopinath, P.G.; Bhatia, M.L.

    1989-01-01

    Rheumatic fever (RF) and rheumatic heart disease (RHD) are major health problems in India. The most difficult decision to make in such a setting is whether a patient of acute rheumatic fever has acute rheumatic carditis or not. Physical signs such as a new cardiac murmur, cardiac enlargement, congestive cardiac failure although quoted as pointers to carditis are non-specific specially if the attack is superimposed on pre-existing RHD. Any investigation which will provide an answer to this problem would be very welcome. sup(99m)Tc pyrophosphate (Tc PYP) is a very sensitive indicator of myocardial necrosis in acute myocardial infarction. A study to determine the usefulness of this technique in diagnosis of rheumatic carditis in patients with unequivocal clinical evidence of myocarditis was undertaken. Results are reported. (author). 14 refs

  13. Abdominal scanning with technetium-99m pertechnetate localizes ectopic gastric mucosa in the jejunum: case report and review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Karakatsanis, K.G.; Chatzipavlidou, V. (Thessaloniki Univ. (Greece). Dept. of Nuclear Medicine); Zafiriadou, E. (Thessaloniki Univ. (Greece). 2. Dept. of Paediatric Surgery); Mavroudis, N. (Hippocrateion Hospital, Thessaloniki (Greece). Dept. of Diagnostic Radiology); Patsiaoura, K.; Gotzamani-Psarrakos, A. (Hippocrateion Hospital, Thessaloniki (Greece). Dept. of Pathology)

    1993-06-01

    A 16-year old male patient was admitted to hospital because of a fainting episode which was accompanied by diarrhoea that was dark red. All investigations were normal except a low haematocrit, a technetium-99m pertechnetate abdominal scan, which showed a large area of moderate activity in the upper left abdomen, and digital subtraction angiography, which showed bleeding in the same area where the abnormal finding on the pertechnetate scan was found. Ectopic gastric mucosa and a deep ulcer in an otherwise normal jejunum were found during the urgent exploratory laparotomy. (orig.).

  14. Bone scanning in severe external otitis

    International Nuclear Information System (INIS)

    Levin, W.J.; Shary, J.H. III; Nichols, L.T.; Lucente, F.E.

    1986-01-01

    Technetium99 Methylene Diphosphate bone scanning has been considered an early valuable tool to diagnose necrotizing progressive malignant external otitis. However, to our knowledge, no formal studies have actually compared bone scans of otherwise young, healthy patients with severe external otitis to scans of patients with clinical presentation of malignant external otitis. Twelve patients with only severe external otitis were studied with Technetium99 Diphosphate and were compared to known cases of malignant otitis. All scans were evaluated by two neuroradiologists with no prior knowledge of the clinical status of the patients. Nine of the 12 patients had positive bone scans with many scans resembling those reported with malignant external otitis. Interestingly, there was no consistent correlation between the severity of clinical presentation and the amount of Technetium uptake. These findings suggest that a positive bone scan alone should not be interpreted as indicative of malignant external otitis

  15. Technetium chemistry

    International Nuclear Information System (INIS)

    Burns, C.; Bryan, J.; Cotton, F.; Ott, K.; Kubas, G.; Haefner, S.; Barrera, J.; Hall, K.; Burrell, A.

    1996-01-01

    Technetium chemistry is a young and developing field. Despite the limited knowledge of its chemistry, technetium is the workhorse for nuclear medicine. Technetium is also a significant environmental concern because it is formed as a byproduct of nuclear weapons production and fission-power generators. Development of new technetium radio-pharmaceuticals and effective environmental control depends strongly upon knowledge of basic technetium chemistry. The authors performed research into the basic coordination and organometallic chemistry of technetium and used this knowledge to address nuclear medicine and environmental applications. This is the final report of a three-year Laboratory-Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL)

  16. Extramedullary pulmonary hematopoiesis causing pulmonary hypertension and severe tricuspid regurgitation detected by 99m technetium sulfur colloid bone marrow scan and single-photon emission computed tomography/CT

    International Nuclear Information System (INIS)

    Ali, Syed Zama; Clarke, Michael John; Kannivelu, Anbalagan; Chinchure, Dinesh; Srinivasan, Sivasubramanian

    2014-01-01

    Extramedullary pulmonary hematopoiesis is a rare entity with a limited number of case reports in the available literature only. We report the case of a 66-year-old man with known primary myelofibrosis, in whom a 99m technetium sulfur colloid bone marrow scan with single-photon emission computed tomography (SPECT)/CT revealed a pulmonary hematopoiesis as the cause of pulmonary hypertension and severe tricuspid regurgitation. To the best of our knowledge, this is the first description of 99m technetium sulfur colloid SPECT/CT imaging in this rare condition.

  17. Synthesis and thermal behavior of double copper and potassium pyrophosphate

    International Nuclear Information System (INIS)

    Ciopec, Mihaela; Muntean, Cornelia; Negrea, Adina; Lupa, Lavinia; Negrea, Petru; Barvinschi, Paul

    2009-01-01

    This paper presents the synthesis and thermal behavior of double copper and potassium pyrophosphate, which can be used as a PK fertilizer containing copper as micronutrient. In order to find the conditions for the synthesis of this compound from copper sulphate and potassium pyrophosphate, various Cu 2+ :P 2 O 7 4- molar ratios (0:1-2:1), various molar concentrations of the solutions (0.075; 0.1; 0.15 and 0.2 mol L -1 ) and various temperatures (25, 50, 75 and 100 o C) have been used. The solid product synthesized in optimum conditions for the separation of micronutrient copper from the reaction mass (Cu 2+ :P 2 O 7 4- molar ratio 1:1, concentration 0.1 mol L -1 ) was subjected to a complex study: chemical analysis, thermal analysis, energy dispersive X-ray spectroscopy, scanning electron microscopy and X-ray diffractometry. During heating up to 1000 o C, K 2 Cu 3 (P 2 O 7 ) 2 .3H 2 O loses the crystallization water; several transformations of the phosphates also take place: the decomposition of pyrophosphates to ortho-phosphates; the transformation of ortho-phosphates; the polymerization of a fraction of ortho-phosphates to amorphous phosphates with longer chains; the reorganization of ortho-phosphates and poly-phosphates to pyrophosphates and their crystallization. The decomposition mechanism was confirmed when using the X-ray diffraction patterns of the compound, thermally treated at several temperatures.

  18. Assessment of inflammatory bowel disease activity by technetium 99m phagocyte scanning

    International Nuclear Information System (INIS)

    Pullman, W.E.; Sullivan, P.J.; Barratt, P.J.; Lising, J.; Booth, J.A.; Doe, W.F.

    1988-01-01

    Autologous technetium 99m-labeled phagocyte scanning has been used to assess disease activity in inflammatory bowel disease in 51 consecutive patients. Strong correlations were found between the 24-h fecal excretion of isotope and the histologic score of mucosal biopsy specimens (rS = 0.84, p less than 0.001, where rS is Spearman's rank correlation coefficient), and between the 24-h fecal excretion of isotope and a clinical inflammatory bowel disease activity index based on the Crohn's disease activity index (rS = 0.87, p less than 0.001). To develop a clinically useful and objective measure of inflammatory bowel disease activity that did not require a 24-h stool collection, the intensity of bowel uptake on scanning was graded visually from 0 to 4, a ratio of count rates for the region of interest to the iliac crest reference region was calculated, and the rapidity of labeled phagocyte uptake into inflamed bowel was measured as the peak uptake time. Visual grading of disease activity on the scans was validated by comparing it with the ratio of count rates from inflamed bowel regions of interest and those from the iliac crest reference region. The ratio of count rates showed a significant correlation with the clinical disease activity index (r = 0.75, p less than 0.001). The visual scan grade also correlated well with the clinical activity index (r = 0.87, p less than 0.001). Count rates from hourly scans were also used to calculate the time of peak uptake of counts for a given region of interest. There was a strong negative correlation between this peak uptake time and the fecal excretion of isotope (rS = -0.81, p less than 0.001), a clinical activity index (r = -0.60, p less than 0.001), and the histologic score of the mucosal biopsy specimens (r = -0.84, p less than 0.001)

  19. Comparison of early myocardial technetium-99m pyrophosphate uptake to early peaking of creatine kinase and creatine kinase-MB as indicators of early reperfusion in acute myocardial infarction

    International Nuclear Information System (INIS)

    Kondo, M.; Yuzuki, Y.; Arai, H.; Shimizu, K.; Morikawa, M.; Shimono, Y.

    1987-01-01

    The value of technetium-99m pyrophosphate (Tc-99m-PYP) scintigraphy as an indicator of reperfusion 2.8 to 8 hours after the onset of symptoms of acute myocardial infarction was compared with the value of early peak creatine kinase (CK) and CK-MB release within 16 hours after the onset of symptoms. In 29 patients who received thrombolytic therapy, recanalization was seen (group 1) and in 7 it was not (group 2). In 23 patients (79%) in group 1 scintigraphic findings were positive and in all 7 in group 2 they were negative. In 15 patients (52%) in group 1 and 1 patient (14%) in group 2, CK reached its peak level within 16 hours. In 20 patients (69%) in group 1 and 3 (43%) in group 2 the CK-MB level reached a peak within 16 hours. The sensitivity, specificity and predictive accuracy of positive results of early Tc-99m-PYP scintigraphy in predicting the reperfusion were 79%, 100% and 83%. These values are significantly higher than or similar to those of early peaking of CK and CK-MB release. In contrast to measurements of enzyme release, reperfusion data for Tc-99m-PYP scintigraphy are available immediately after thrombolytic therapy. Therefore, early Tc-99m-PYP scintigraphy (3 to 8 hours after onset of symptoms) is valuable as a noninvasive technique for early diagnosis of reperfusion

  20. Radiopharmaceutical scanning agents

    International Nuclear Information System (INIS)

    1976-01-01

    This invention is directed to dispersions useful in preparing radiopharmaceutical scanning agents, to technetium labelled dispersions, to methods for preparing such dispersions and to their use as scanning agents

  1. Uptake of myocardial imaging agents by rejected hearts

    International Nuclear Information System (INIS)

    Bergsland, J.; Carr, E.A.; Carroll, M.; Wright, J.W.; Feldman, M.J.; Massucci, J.; Bhayana, J.N.; Gona, J.M.

    1985-01-01

    Technetium 99 m pyrophosphate, Gallium 67 and Thallium 201 uptakes were measured in heterotopically transplanted rat hearts. Five days after transplantation, Technetium 99 m pyrophosphate, and Gallium 67 uptakes were significantly higher in allogeneic grafts than in syngeneic grafts. At an early stage of rejection (three days after transplantation), only Technetium 99 m pyrophosphate uptake in the left ventricle of allogeneic grafts showed a significant difference (p less than 0.04). At five days, Thallium 201 uptake was significantly lower in allo- than syngeneic grafts. There was a positive correlation between radionuclide uptake and histologic degree of rejection for Technetium 99 m pyrophosphate and Gallium 67 while Thallium 201 uptake correlated negatively. Analysis of variance revealed that hearts with no or minimal rejection had statistically different uptakes than hearts with mild to moderate rejection. These results suggest that uptake of imaging agents might be useful in the diagnosis of rejection of the transplanted heart

  2. Extramedullary pulmonary hematopoiesis causing pulmonary hypertension and severe tricuspid regurgitation detected by {sup 99m} technetium sulfur colloid bone marrow scan and single-photon emission computed tomography/CT

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Syed Zama; Clarke, Michael John; Kannivelu, Anbalagan; Chinchure, Dinesh; Srinivasan, Sivasubramanian [Dept. of Diagnostic Radiology, Khoo Teck Puat Hospital, Singapore (Singapore)

    2014-06-15

    Extramedullary pulmonary hematopoiesis is a rare entity with a limited number of case reports in the available literature only. We report the case of a 66-year-old man with known primary myelofibrosis, in whom a {sup 99m}technetium sulfur colloid bone marrow scan with single-photon emission computed tomography (SPECT)/CT revealed a pulmonary hematopoiesis as the cause of pulmonary hypertension and severe tricuspid regurgitation. To the best of our knowledge, this is the first description of {sup 99m} technetium sulfur colloid SPECT/CT imaging in this rare condition.

  3. Anterior ST depression with acute transmural inferior infarction due to posterior infarction. A vectorcardiographic and scintigraphic study

    International Nuclear Information System (INIS)

    Mukharji, J.; Murray, S.; Lewis, S.E.; Croft, C.H.; Corbett, J.R.; Willerson, J.T.; Rude, R.E.

    1984-01-01

    The hypothesis that anterior ST segment depression represents concomitant posterior infarction was tested in 49 patients admitted with a first transmural inferior myocardial infarction. Anterior ST depression was defined as 0.1 mV or more ST depression in leads V1, V2 or V3 on an electrocardiogram recorded within 18 hours of infarction. Serial vectorcardiograms and technetium pyrophosphate scans were obtained. Eighty percent of the patients (39 of 49) had anterior ST depression. Of these 39 patients, 34% fulfilled vectorcardiographic criteria for posterior infarction, and 60% had pyrophosphate scanning evidence of posterior infarction. Early anterior ST depression was neither highly sensitive (84%) nor specific (20%) for the detection of posterior infarction as defined by pyrophosphate imaging. Of patients with persistent anterior ST depression (greater than 72 hours), 87% had posterior infarction detected by pyrophosphate scan. In patients with inferior myocardial infarction, vectorcardiographic evidence of posterior infarction correlated poorly with pyrophosphate imaging data. Right ventricular infarction was present on pyrophosphate imaging in 40% of patients with pyrophosphate changes of posterior infarction but without vectorcardiographic evidence of posterior infarction. It is concluded that: 1) the majority of patients with acute inferior myocardial infarction have anterior ST segment depression; 2) early anterior ST segment depression in such patients is not a specific marker for posterior infarction; and 3) standard vectorcardiographic criteria for transmural posterior infarction may be inaccurate in patients with concomitant transmural inferior myocardial infarction or right ventricular infarction, or both

  4. Synthesis and Properties of Metallic Technetium and Technetium-Zirconium Alloys as Transmutation Target and Radioactive waste storage form in the UREX+1 Process

    Energy Technology Data Exchange (ETDEWEB)

    Hartmann, Thomas [Idaho State University/Idaho National Laboratory, 1776 Science Center Drive, Idaho Falls, ID 83402 (United States)]|[Harry Reid Center, University Nevada - Las Vegas, 4505 Maryland Parkway, Las Vegas, NV (United States); Poineau, Frederic; Czerwinski, Kenneth R. [Harry Reid Center, University Nevada - Las Vegas, 4505 Maryland Parkway, Las Vegas, NV (United States)

    2008-07-01

    In the application of UREX+1 process, technetium will be separated together with uranium and iodine within the first process step. After the separation of uranium, technetium and iodine must be immobilized by their incorporation in a suitable waste storage-form. Based on recent activities within the AFCI community, a potential candidate as waste storage form to immobilize technetium is to alloy the metal with excess zirconium. Alloys in the binary Tc-Zr system may act as potential transmutation targets in order to transmute Tc-99 into Ru-100. We are presenting first results in the synthesis of metallic technetium, and the synthesis of equilibrium phases in the binary Tc-Zr system at 1400 deg. C after arc-melting and isothermal annealing under inert conditions. Samples were analyzed using X-ray powder diffraction, Rietveld analysis, scanning electron microscopy, and electron probe micro-analysis, which allows us to construct the binary Tc-Zr phase diagram for the isothermal section at 1400 deg. C. (authors)

  5. Evaluation of technetium 99m-HMPAO leukocyte scanning in the assessment of disease extent and activity in inflammatory bowel disease

    International Nuclear Information System (INIS)

    Morelec, I.; Bracquemart, P.; Beades, E.; Bouvard, G.; Fellous, F.; Piquet, M.A.; Dao, T.; Verwaerde, J.C.; Coste, J.

    1993-01-01

    We have studied prospectively the usefulness of HMPAO 99m Tc leucocytes scan in patients with Crohn's disease and ulcerative colitis. Abdominal scans were performed 1 h and 2 h 30 after injection of an autologous leukocyte preparation containing 100-200 MBq of Technetium 99m. The extent of bowel involvement, evaluated on the 2 h 30 scan, was compared to X-rays and endoscopic findings. The disease activity was quantified by the intensity of intestinal radionuclide uptake on the 2 h 30 scan and compared with the Crohn's disease activity index (CDAI) sedimentation rate. Forty-five examinations were performed in 40 patients with Crohn's disease or ulcerative colitis. The correlation of the number of locations between leukocyte scan and other diagnosis procedures was good in 40 cases. CDAI was significantly correlated with radionuclide index. Two fistulae and one abscess and small bowel involvement were correctly visualized. This technique provides images of excellent quality, superior to those obtained with indium 111. Therefore, we believe that this test can be useful in the follow-up of patients with Crohn's disease and ulcerative colitis

  6. Clinical usefulness of scintigraphy with 99mTechnetium phosphates in rhabdomyolysis

    International Nuclear Information System (INIS)

    Aizawa, Nobuyuki; Hara, Yoshikuni; Suzuki, Yutaka; Akashi, Tsunehiro; Kamei, Tetsumasa; Uchiyama, Fujio; Mitsui, Tamito; Yamazaki, Yuki.

    1990-01-01

    We performed bone scans with 99m Technetium phosphates in 15 cases of clinically suspected rhabdomyolysis admitted to Chigasaki Tokushukai Hospital. Whole body scans were performed within 5 days from the onset of illness or admission. Accumulation of the radioactivity in the skeletal muscle was revealed in 13 of the 15 cases and the involved muscle groups were visualized vividly. Etiologies of rhabdomyolysis were diverse, ranging from malignant syndrome to sepsis. Myocardial concentration was absent in all of the cases. Renal concentration of the isotope was seen in cases where the degree of rhabdomyolysis was higher and renal impairment was present. We conclude that 99m Technetium phosphate bone scan is useful in clinically suspected rhabdomyolysis as a diagnostic test and as a test to localize and quantitate the muscular involvement. (author)

  7. Chemistry of Technetium

    International Nuclear Information System (INIS)

    Omori, Takashi

    2001-01-01

    Since the late 1970's the coordination chemistry of technetium has been developed remarkably. The background of the development is obviously related to the use of technetium radiopharmaceuticals for diagnosis in nuclear medicine. Much attention has also been denoted to the chemical behavior of environmental 99 Tc released from reprocessing plants. This review covers the several aspects of technetium chemistry, including production of radioisotopes, analytical chemistry and coordination chemistry. In the analytical chemistry, separation of technetium, emphasizing chromatography and solvent extraction, is described together with spectrophotometric determination of technetium. In the coordination chemistry of technetium, a characteristic feature of the chemistry of Tc(V) complexes is referred from the view point of the formation of a wide variety of highly stable complexes containing the Tc=O or Tc≡N bond. Kinetic studies of the preparation of Tc(III) complexes using hexakis (thiourea) technetium(III) ion as a starting material are summarized, together with the base hydrolysis reactions of Tc(III), Tc(IV) and Tc(V) complexes. (author)

  8. β-pyrophosphate: A potential biomaterial for dental applications

    Energy Technology Data Exchange (ETDEWEB)

    Anastasiou, A.D., E-mail: a.anastasiou@leeds.ac.uk [School of Chemical and Process Engineering, University of Leeds, Leeds LS2 9JT (United Kingdom); Strafford, S. [Leeds Dental School, Worsley Building, University of Leeds, Leeds LS2 9JT (United Kingdom); Posada-Estefan, O. [Leeds Institute of Cardiovascular and Metabolic Medicine, Faculty of Medicine and Health, University of Leeds, LS2 9JT (United Kingdom); Thomson, C.L. [SUPA, School of Physics and Astronomy, University of St Andrews, North Haugh, St Andrews, Fife KY16 9SS (United Kingdom); Hussain, S.A. [SUPA, School of Physics and Astronomy, University of St Andrews, North Haugh, St Andrews, Fife KY16 9SS (United Kingdom); Cambridge Graphene Centre, Engineering Department, University of Cambridge, 9, JJ Thomson Avenue, Cambridge CB3 0FA (United Kingdom); Edwards, T.J. [SUPA, School of Physics and Astronomy, University of St Andrews, North Haugh, St Andrews, Fife KY16 9SS (United Kingdom); Malinowski, M. [Leeds Dental School, Worsley Building, University of Leeds, Leeds LS2 9JT (United Kingdom); Hondow, N. [School of Chemical and Process Engineering, University of Leeds, Leeds LS2 9JT (United Kingdom); Metzger, N.K.; Brown, C.T.A. [SUPA, School of Physics and Astronomy, University of St Andrews, North Haugh, St Andrews, Fife KY16 9SS (United Kingdom); Routledge, M.N. [Leeds Institute of Cardiovascular and Metabolic Medicine, Faculty of Medicine and Health, University of Leeds, LS2 9JT (United Kingdom); Brown, A.P. [School of Chemical and Process Engineering, University of Leeds, Leeds LS2 9JT (United Kingdom); Duggal, M.S. [Leeds Dental School, Worsley Building, University of Leeds, Leeds LS2 9JT (United Kingdom); Jha, A. [School of Chemical and Process Engineering, University of Leeds, Leeds LS2 9JT (United Kingdom)

    2017-06-01

    Tooth hypersensitivity is a growing problem affecting both the young and ageing population worldwide. Since an effective and permanent solution is not yet available, we propose a new methodology for the restoration of dental enamel using femtosecond lasers and novel calcium phosphate biomaterials. During this procedure the irradiated mineral transforms into a densified layer of acid resistant iron doped β-pyrophosphate, bonded with the surface of eroded enamel. Our aim therefore is to evaluate this densified mineral as a potential replacement material for dental hard tissue. To this end, we have tested the hardness of β-pyrophosphate pellets (sintered at 1000 °C) and its mineral precursor (brushite), the wear rate during simulated tooth-brushing trials and the cytocompatibility of these minerals in powder form. It was found that the hardness of the β-pyrophosphate pellets is comparable with that of dental enamel and significantly higher than dentine while, the brushing trials prove that the wear rate of β-pyrophosphate is much slower than that of natural enamel. Finally, cytotoxicity and genotoxicity tests suggest that iron doped β-pyrophosphate is cytocompatible and therefore could be used in dental applications. Taken together and with the previously reported results on laser irradiation of these materials we conclude that iron doped β-pyrophosphate may be a promising material for restoring acid eroded and worn enamel. - Highlights: • A novel procedure for the restoration of dental enamel is introduced. • Fe-doped ß-pyrophosphate is evaluated as potential biomaterial for enamel restoration. • Fe-doped ß-pyrophosphate found to have the same hardness as natural enamel and dramatically lower wear rate. • Cytotoxicity and genotoxicity tests suggest that Fe-doped ß-pyrophosphate is safe for dental applications.

  9. β-pyrophosphate: A potential biomaterial for dental applications

    International Nuclear Information System (INIS)

    Anastasiou, A.D.; Strafford, S.; Posada-Estefan, O.; Thomson, C.L.; Hussain, S.A.; Edwards, T.J.; Malinowski, M.; Hondow, N.; Metzger, N.K.; Brown, C.T.A.; Routledge, M.N.; Brown, A.P.; Duggal, M.S.; Jha, A.

    2017-01-01

    Tooth hypersensitivity is a growing problem affecting both the young and ageing population worldwide. Since an effective and permanent solution is not yet available, we propose a new methodology for the restoration of dental enamel using femtosecond lasers and novel calcium phosphate biomaterials. During this procedure the irradiated mineral transforms into a densified layer of acid resistant iron doped β-pyrophosphate, bonded with the surface of eroded enamel. Our aim therefore is to evaluate this densified mineral as a potential replacement material for dental hard tissue. To this end, we have tested the hardness of β-pyrophosphate pellets (sintered at 1000 °C) and its mineral precursor (brushite), the wear rate during simulated tooth-brushing trials and the cytocompatibility of these minerals in powder form. It was found that the hardness of the β-pyrophosphate pellets is comparable with that of dental enamel and significantly higher than dentine while, the brushing trials prove that the wear rate of β-pyrophosphate is much slower than that of natural enamel. Finally, cytotoxicity and genotoxicity tests suggest that iron doped β-pyrophosphate is cytocompatible and therefore could be used in dental applications. Taken together and with the previously reported results on laser irradiation of these materials we conclude that iron doped β-pyrophosphate may be a promising material for restoring acid eroded and worn enamel. - Highlights: • A novel procedure for the restoration of dental enamel is introduced. • Fe-doped ß-pyrophosphate is evaluated as potential biomaterial for enamel restoration. • Fe-doped ß-pyrophosphate found to have the same hardness as natural enamel and dramatically lower wear rate. • Cytotoxicity and genotoxicity tests suggest that Fe-doped ß-pyrophosphate is safe for dental applications.

  10. sup(99m)Tc-pyrophosphate scintiscanning in diagnostic orthopaedics

    International Nuclear Information System (INIS)

    Rauscher, W.

    1983-01-01

    To assess the findings of nuclear skeletal examinations, the pathological course of the disease must be known as far as possible. Pyrophosphate is the substance that causes bone accumulation while the metastable technetium is a high-intensity gamma source. Positive scintiscan findings are obtained in all processes with clear changes in the bone structure, e.g. all stages of osteomyelitis, articular processes of different genesis, inflammations, or activations of the bone metabolism. In these cases also processes of the articular cartilage and, partly, the soft tissue will be imaged. Terminated processes and purely degenerative changes, which are rare in clinical practice, will remain quiescent. Examinations after trauma or after surgery show a typical healing process. Scintiscanning is particularly useful for examinations of skeletal parts that are difficult to image by radiological methods; on the other hand, it does not yield additional information on the fit of an endoprothesis. Primary skeletal tumours can be diagnosed with sufficient accuracy only by means of quantitative methods. Nuclear methods, with their accurate information on the dynamics of the bone metabolism, often yield valuable additional information for the purposes of diagnosis, therapy, and prognosis. (orig./MG) [de

  11. Technetium myocardial perfusion scanning in prerenal transplant evaluation in the United kingdom.

    LENUS (Irish Health Repository)

    Wong, C F

    2008-06-01

    Because death with a functioning graft remains one of the most important causes of long-term renal transplant failure, cardiac risk stratification and screening for coronary artery disease are essential components of pretransplant assessment. Pretransplant screening for occult coronary artery disease in a subset of these patients may improve outcome. The UK follows the European Best practice guideline 1.5.5 E. Although echocardiography, thallium myocardial perfusion scanning (MPS), dobutamine stress echocardiography, and coronary angiography have been suggested as means of cardiovascular assessment, the best means of assessment remains undetermined. Therefore, we investigated the role of 99m technetium sestamibi myocardial perfusion scanning as an assessment tool for identifying those patients with end-stage renal failure at high risk of cardiovascular death after renal transplantation. Retrospectively, we studied 126 patients that had a MPS as part of their pretransplant assessment. Overall unadjusted survival was 65% at 3 years. Twelve deaths resulted from cardiovascular causes. A reversible defect on MPS was associated with a fatal cardiac event and all-cause mortality. The unadjusted hazard ratio of cardiac event with reversible defect on MPS was 3.1 (95% confidence interval, 1.1 to 18.2) and hazard ratio of death with reversible defect on MPS was 1.92 (95% confidence interval, 1.1 to 4.4). Thus, MPS may be a useful tool in cardiac risk stratification and in selecting patients with a favorable outcome after renal transplantation. Our patients with a reversible defect in particular have increased cardiac mortality. This group may benefit from coronary angiography.

  12. Visualization of rhabdomyolysis with scintigraphy with Tc99m pyrophosphate: presentation of a clinical case

    International Nuclear Information System (INIS)

    Pruzzo C, Rossana; Amaral P, Horacio; Morales K, Barbara; Hurtado, Ester

    2000-01-01

    We present a case of secondary rhabdomyolysis due to vascular ischemia after dissection of the proximal aorta and obstruction of the left femoral artery after cocaine consumption. A Tc99m-pyrophosphate whole body scan demonstrated the presence of rhabdomyolysis in both lower extremities (Au)

  13. Clinical usefulness of scintigraphy with sup 99m Technetium phosphates in rhabdomyolysis

    Energy Technology Data Exchange (ETDEWEB)

    Aizawa, Nobuyuki; Hara, Yoshikuni (Shonan Kamakura Hospital, Kanagawa (Japan)); Suzuki, Yutaka; Akashi, Tsunehiro; Kamei, Tetsumasa; Uchiyama, Fujio; Mitsui, Tamito; Yamazaki, Yuki

    1990-08-01

    We performed bone scans with {sup 99m}Technetium phosphates in 15 cases of clinically suspected rhabdomyolysis admitted to Chigasaki Tokushukai Hospital. Whole body scans were performed within 5 days from the onset of illness or admission. Accumulation of the radioactivity in the skeletal muscle was revealed in 13 of the 15 cases and the involved muscle groups were visualized vividly. Etiologies of rhabdomyolysis were diverse, ranging from malignant syndrome to sepsis. Myocardial concentration was absent in all of the cases. Renal concentration of the isotope was seen in cases where the degree of rhabdomyolysis was higher and renal impairment was present. We conclude that {sup 99m}Technetium phosphate bone scan is useful in clinically suspected rhabdomyolysis as a diagnostic test and as a test to localize and quantitate the muscular involvement. (author).

  14. Radiographic scanning agent

    International Nuclear Information System (INIS)

    Bevan, J.A.

    1983-01-01

    This invention relates to radiodiagnostic agents and more particularly to a composition and method for preparing a highly effective technetium-99m-based bone scanning agent. One deficiency of x-ray examination is the inability of that technique to detect skeletal metastases in their incipient stages. It has been discovered that the methanehydroxydiphosphonate bone mineral-seeking agent is unique in that it provides the dual benefits of sharp radiographic imaging and excellent lesion detection when used with technetium-99m. This agent can also be used with technetium-99m for detecting soft tissue calcification in the manner of the inorganic phosphate radiodiagnostic agents

  15. Use of blood-pool imaging in evaluation of diffuse activity patterns in technetium-99m pyrophosphate myocardial scintigraphy.

    Science.gov (United States)

    Cowley, M J; Mantle, J A; Rogers, W J; Russell, R O; Rackley, C E; Logic, J R

    1979-06-01

    It has been suggested that diffuse Tc-99m pyrophosphate precordial activity may be due to persistent blood-pool activity in routine delayed views during myocardial imaging. To answer this question, we reviewed myocardial scintigrams recorded 60--90 min following the injection of 12--15 mCi of Tc-99m pyrophosphate for the presence of diffuse precordial activity, and compared these with early images of the blood pool in 265 patients. Diffuse activity in the delayed images was identified in 48 patients: in 20 with acute myocardial infarction and in 28 with no evidence of it. Comparison of these routine delayed images with early views of the blood pool revealed two types of patterns. In patients with acute infarction, 95% had delayed images that were distinguishable from blood pool either because the activity was smaller than the early blood pool, or by the presence of localized activity superimposed on diffuse activity identical to blood pool. In those without infarction, 93% had activity distribution in routine delayed views matching that in the early blood-pool images. The usefulness of the diffuse TcPPi precordial activity in myocardial infarction is improved when early blood-pool imaging is used to exclude persistence of blood-pool activity as its cause. Moreover, it does not require additional amounts of radioactivity nor complex computer processing, a feature that may be of value in the community hospital using the technique to "rule out" infarction 24--72 hr after onset of suggestive symptoms.

  16. Technetium in environmental waters

    International Nuclear Information System (INIS)

    Malcolme-Lawes, D.J.; Robb, P.; Warwick, P.

    1983-01-01

    A method for the determination of technetium in a sample of environmental water is described. Technetium, in the TcO 4 - form, is extracted from the sample onto an anion-exchange resin from which it is removed subsequently by washing with 4 M sodium thiocyanate solution. The eluted technetium-thiocyanate complex is then subjected to solvent extraction, where the technetium is further concentrated into butan-2-one. The organic phase is evaporated onto a planchette and the β activity due to the technetium determined by an anticoincidence Geiger counter. Detection limits of 0.5 ng of technetium-99 have been obtained for the counter and sample volumes in excess of 500 cm 3 can be analysed readily. The sorption of several technetium compounds onto soil from a variety of water types has also been investigated. Preliminary results are presented and the importance of the chemical form of technetium used in such studies is discussed briefly. (author)

  17. Dissolution behaviour of ferric pyrophosphate and its mixtures with soluble pyrophosphates: Potential strategy for increasing iron bioavailability.

    Science.gov (United States)

    Tian, Tian; Blanco, Elena; Smoukov, Stoyan K; Velev, Orlin D; Velikov, Krassimir P

    2016-10-01

    Ferric pyrophosphate (FePP) is a widely used iron source in food fortification and in nutritional supplements, due to its white colour, that is very uncommon for insoluble Fe salts. Although its dissolution is an important determinant of Fe adsorption in human body, the solubility characteristics of FePP are complex and not well understood. This report is a study on the solubility of FePP as a function of pH and excess of pyrophosphate ions. FePP powder is sparingly soluble in the pH range of 3-6 but slightly soluble at pH8. In the presence of pyrophosphate ions the solubility of FePP strongly increases at pH 5-8.5 due to formation a soluble complex between Fe(III) and pyrophosphate ions, which leads to an 8-10-fold increase in the total ionic iron concentration. This finding is beneficial for enhancing iron bioavailability, which important for the design of fortified food, beverages, and nutraceutical products. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Use of blood-pool imaging in evaluation of diffuse activity patterns in technetium-99m pyrophosphate myocardial scintigraphy

    International Nuclear Information System (INIS)

    Cowley, M.J.; Mantle, J.A.; Rogers, W.J.; Russell, R.O. Jr.; Rackley, C.E.; Logic, J.R.

    1979-01-01

    It has been suggested that diffuse 99m Tc pyrophosphate precordial activity may be due to persistent blood-pool activity in routine delayed views during myocardial imaging. To answer this question, we reviewed myocardial scintigrams recorded 60 to 90 min following the injection of 12 to 15 mCi of 99m Tc pyrophosphate for the presence of diffuse precordial activity, and compared these with early images of the blood pool in 265 patients. Diffuse activity in the delayed images was identified in 48 patients: in 20 with acute myocardial infarction and in 28 with no evidence of it. Comparison of these routine delayed images with early views of the blood pool revealed two types of patterns. In patients with acute infarction, 95% had delayed images that were distinguishable from blood pool either because the activity was smaller than the early blood pool, or by the presence of localized activity superimposed on diffuse activity identical to blood pool. In those without infarction, 93% had activity distribution in routine delayed views matching that in the early blood-pool images. The usefulness of the diffuse TcPPi precordial activity in myocardial infarction is improved when early blood-pool imaging is used to exclude persistence of blood-pool activity as its cause. Moreover, it does not require additional amounts of radioactivity nor complex computer processing, a feature that may be of value in the community hospital using the technique to rule out infarction 24 to 72 hr after onset of suggestive symptoms

  19. Nitrosyl complexes of technetium; Nitrosylkomplexe des Technetiums

    Energy Technology Data Exchange (ETDEWEB)

    Ackermann, Janine

    2016-09-22

    The presented thesis describes syntheses and characterization of novel technetium nitrosyl compounds with various ligand systems. The main focus is the synthesis of low-valent technetium nitrosyl complexes with cyclopentadienyl ligands. [German] Gegenstand der vorliegenden Arbeit ist die Synthese und Charakterisierung neuer Technetiumnitrosylverbindungen mit unterschiedlichen Ligandensystemen. Hauptaugenmerk wurde dabei auf die Darstellung niedervalenter Tc(NO)-Verbindungen mit Cyclopentadienyl-Liganden gelegt.

  20. Ceramics based on calcium pyrophosphate nanopowders

    Directory of Open Access Journals (Sweden)

    Tatiana V. Safronova

    2013-03-01

    Full Text Available Present work is aimed at the fabrication of resorbable bioceramics based on calcium pyrophosphate (CPP from the synthesized powders of amorphous hydrated calcium pyrophosphate (AHCPP. Amorphous hydratedcalcium pyrophosphate in the form of nanopowders was precipitated from Ca(NO3 2 and (NH4 4P2O7 solutions at room temperature in the presence of PO3– ions. Crystalline CPP powder was fabricated from AHCPP by its thermal decomposition at 600 °C and consisted of β- and α- phase. Small particles, with the size less than 200 nm, were formed promoting sintering of the ceramic material. The final sample, sintered at 900 °C, exhibits microstructure with submicron grains, apparent density of 87% of theoretical density (TD and demonstrates tensile strength of 70 MPa.

  1. PREDICTION OF RELAPSE FROM HYPERTHYROIDISM FOLLOWING ANTITHYROID MEDICATION WITHDRAWAL USING TECHNETIUM THYROID UPTAKE SCANNING.

    Science.gov (United States)

    Nakhjavani, Manouchehr; Abdollahi, Soraya; Farzanefar, Saeed; Abousaidi, Mohammadtagi; Esteghamati, Alireza; Naseri, Maryam; Eftekhari, Mohamad; Abbasi, Mehrshad

    2017-04-02

    Technetium thyroid uptake (TTU) is not inhibited by antithyroid drugs (ATD) and reflects the degree of thyroid stimulation. We intended to predict the relapse rate from hyperthyroidism based on TTU measurement. Out of 44 initially enrolled subjects, 38 patients aged 41.6 ± 14.6 with Graves disease (duration: 84 ± 78 months) completed the study. TTU was performed with 40-second imaging of the neck and mediastinum 20 minutes after injection of 1 mCi technetium-99m pertechnetate. TTU was measured as the percentage of the count of activity accumulated in the thyroidal region minus the mediastinal background uptake to the count of 1 mCi technetium-99m under the same acquisition conditions. Then methimazole was stopped and patients were followed. The optimal TTU cutoff value for Graves relapse prediction was calculated using Youden's J statistic. Hyperthyroidism relapsed in 11 (28.9%) patients 122 ± 96 (range: 15-290) days post-ATD withdrawal. The subjects in remission were followed for 209 ± 81 days (range: 88-390). TTU was significantly higher in patients with forthcoming relapse (12.0 ± 8.0 vs. 3.9 ± 2.0, P = .007). The difference was significant after adjustment for age, sex, history of previous relapse, disease duration, and thyroid-stimulating hormone (TSH) levels before withdrawal. The area under the receiver operative characteristic (ROC) curve was 0.87. The optimal TTU cutoff value for classification of subjects with relapse and remission was 8.7 with sensitivity, specificity, and positive and negative predictive value of 73%, 100%, 100%, and 90%, respectively (odds ratio [OR] = 10.0; 95% confidence interval [CI]: 3.4-29.3). TTU evaluation in hyperthyroid patients receiving antithyroid medication is an accurate and practical method for predicting relapse after ATD withdrawal. ATD = antithyroid drugs RIU = radio-iodine uptake TSH = thyroid-stimulating hormone TSI = thyroid-stimulating immunoglobulin TTU = technetium thyroid uptake.

  2. Investigation of space-occupying lesions in the liver with technetium-99m tin colloid and indium-113m-chloride

    International Nuclear Information System (INIS)

    Nelson, M.J.; Klopper, J.F.

    1985-01-01

    Liver scanning with radiocolloids is an important method to determine the presence, the position and the size of space-occupying lesions in the liver. Unfortunately, this information is nonspecific and it is not possible to distinguish between tumours, abscesses or cysts. Thirty-six patients in whom a definite diagnosis of hepatoma, amoebic liver abscess or echinococcus cyst had been made were examined with technetium-99m tin colloid and indium-113m chloride. The amoebic liver abscesses were avascular, showed a hyperaemic area surrounding the abscess and appeared smaller on the indium than on the technetium scan. The hepatomas showed greater vascularity and absence of the hyperaemic area. Cysts were avascular, did not show a hyperaemic rim and the size was equal on both scans. The experience of the observers had an influence on the accuracy of interpretation of the scans; experienced observers made a correct diagnosis in 73% of cases. It is suggested that simultaneous technetium-99m tin colloid and indium 113m-chloride scans provide additional specificity in the differential diagnosis between hepatoma, amoebic liver abscess and echinococcus cysts

  3. Investigation of space-occupying lesions in the liver with technetium-99m tin colloid and indium-113m-chloride

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, M.J. (Provincial Hospital, Port Elizabeth (South Africa). Dept. of Nuclear Medicine); Klopper, J.F. (Stellenbosch Univ. (South Africa). Dept. of Nuclear Medicine)

    1985-01-26

    Liver scanning with radiocolloids is an important method to determine the presence, the position and the size of space-occupying lesions in the liver. Unfortunately, this information is nonspecific and it is not possible to distinguish between tumours, abscesses or cysts. Thirty-six patients in whom a definite diagnosis of hepatoma, amoebic liver abscess or echinococcus cyst had been made were examined with technetium-99m tin colloid and indium-113m chloride. The amoebic liver abscesses were avascular, showed a hyperaemic area surrounding the abscess and appeared smaller on the indium than on the technetium scan. The hepatomas showed greater vascularity and absence of the hyperaemic area. Cysts were avascular, did not show a hyperaemic rim and the size was equal on both scans. The experience of the observers had an influence on the accuracy of interpretation of the scans; experienced observers made a correct diagnosis in 73% of cases. It is suggested that simultaneous technetium-99m tin colloid and indium 113m-chloride scans provide additional specificity in the differential diagnosis between hepatoma, amoebic liver abscess and echinococcus cysts.

  4. Complex diagnostic approaches in skeletal metastases of tumors. I

    International Nuclear Information System (INIS)

    Bek, V.; Janko, L.; Hausner, P.; Konopasek, B.; Novy, F.; Vosecky, M.; Stepan, J.

    1986-01-01

    The results are presented of radionuclide examinations of the skeleton obtained during long-term research of comprehensive diagnosis of metastatic osteopathies. In a group of 922 patients with different malignant tumors where the largest sub-groups are represented by female patients with breast cancer (623 cases), patients with tumors of the testicles (66 patients) and patients with renal carcinoma (64 patients), assessed are the sensitivity, specificity and reliability of two radionuclide methods, i.e., the strontium test ( 85 Sr) and whole-body scanning after administration of technetium-labelled pyrophosphate ( 99m Tc-PYP). During long-term investigations of patients, as a reference finding the evidence of bone metastases by radiography and/or necropsy was selected. Whole-body scanning with technetium-labelled phosphate complexes is at present the method of choice. (author). 10 tabs., 17 refs

  5. Scintigraphic myocardial imaging with sup(99m)Tc-labelled pyrophosphate of experimentally produced cardiomyopathy in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Duska, F.; Novak, J.; Vizda, J.; Kubicek, J.; Kafka, P.; Mazurova, Y.; Bradna, P.

    1981-12-01

    Scintigraphic examination of the myocardium using sup(99m)Tc-labelled pyrophosphate was carried out in 10 dogs with experimentally produced cardiomyopathy. This was brought by introvenous administration of high doses of adrenalin and theophylline. The scan was positive in 8 out of 10 dogs. Hot foci were very extensive. The degree of accumulation was however low (2+). Histological examination of the myocardium using the light microscope showed only scarcely distinguishable damage to the tissue without the presence of necrosis. ECG examinations were normal in all cases. By means of sup(99m)Tc-labelled pyrophosphate even very small myocardial disorders can thus be detected. This fact may be of clinical importance for an early diagnosis of heart lesions.

  6. method and container for production of diagnostic scanning agents

    International Nuclear Information System (INIS)

    Ruddock, C.F.

    1979-01-01

    The pertechnetate ion containing the technetium-99m isotope has limited applications in diagnostic scanning because it does not readily form complexes with materials which locate in specific parts of the body. Stannous salts have been widely used to reduce the pertechnetate to a form which readily complexes with materials. In the present invention, both a container and a more suitable metal reducing agent are discussed for transforming the technetium in pertechnetate for diagnostic scanning use. The vessel contains tin or a tin-containing alloy as a reducing agent for the pertechnetate and a complexant for the reduced technetium; all contents are sterile and dry. The present invention is advantageous over the stannous salts method since (1) problems of stannous salt instability during production, storage and after labelling are eliminated; (2) production procedures are simplified; (3) it is not essential to nitrogen purge vials before sterilisation; (4) it reduces toxicity; (5) the shelf life of diagnostic scanning kits may be dramatically improved; (6) the metal reducing agent may be sterilised by γ-irradiation without deteriorating; (7) the labelling technique can be performed over a wide pH range; and (8) the technique should be unaffected by technetium-99 in the technetium-99m. (U.K.)

  7. Quantitation of size of myocardial infarctions by computerized transmission tomography. Comparison with hot-spot and cold-spot radionuclide scans

    International Nuclear Information System (INIS)

    Gerber, K.H.; Higgins, C.B.

    1983-01-01

    The current study evaluated the ability to quantitate the volume of myocardial infarctions when they are outlined by intravenously administered contrast media in the myocardial perfusion phase and in the phase of delayed contrast enhancement of the infarct. Quantitation by contrast media was assessed from computerized transmission tomography (CTT) scans of the ex situ heart and compared with quantitation by technetium-99m (/sup 99m/Tc)pyrophosphate (/sup 99m/Tc PYP) and thallium-201 (201Tl) scans of the same ex situ hearts. True volume was defined by histochemical morphometry. CTT during the contrast perfusion phase uniformly underestimated infarct size but had a good correlation with true volume. CTT during enhancement phase correlated closely with true volume (r . 0.98) and most precisely measured true size (y . 1.06 X 0.23). The /sup 99m/Tc PYP scan overestimated infarct volume (predictive overestimation of 6 to 199%) but had a good correlation with true volume. 201Tl underestimated infarct volume but correlated well with true volume. Thus, quantitation of infarct volume from CTT scans performed during either the perfusion or infarct enhancement phase after intravenous contrast media provides a good estimate of true infarct volume. Delineation of the infarct by contrast media in the ex situ heart is more precise during the phase of delayed enhancement of the infarct

  8. Technetium in chemistry and nuclear medicine

    International Nuclear Information System (INIS)

    Deutsch, E.; Nicolini, M.; Wagner, H.N.

    1983-01-01

    This volume explores the potential of technetium radiopharmaceuticals in clinical nuclear medicine. The authors examine the capabilities of synthetic inorganic chemists to synthesize technetium radiopharmaceuticals and the specific requirements of the nuclear medicine practitioner. Sections cover the chemistry of technetium, the production of radiopharmaceuticals labeled with technetium, and the use of technetium radiopharmaceuticals in nuclear medicine

  9. Investigating the pharmacodynamic and magnetic properties of pyrophosphate-bridged coordination complexes

    Science.gov (United States)

    Ikotun, Oluwatayo (Tayo) F.

    The multidentate nature of pyrophosphate makes it an attractive ligand for complexation of metal cations. The participation of pyrophosphate in a variety of biological pathways and its metal catalyzed hydrolysis has driven our investigation into its coordination chemistry. We have successfully synthesized a library of binuclear pyrophosphate bridge coordination complexes. The problem of pyrophosphate hydrolysis to phosphate in the presence of divalent metal ions was overcome by incorporating capping ligands such as 1,10-phenanthroline and 2,2'-bipyridine prior to the addition of the pyrophosphate. The magnetic properties of these complexes was investigated and magneto-structural analysis was conducted. The biological abundance of pyrophosphate and the success of metal based drugs such as cisplatin, prompted our investigation of the cytotoxic properties of M(II) pyrophosphate dimeric complexes (where M(II) is CoII, CuII, and NiII) in adriamycin resistant human ovarian cancer cells. Thess compounds were found to exhibit toxicity in the nanomolar to picomolar range. We conducted in vitro stability studies and the mechanism of cytoxicity was elucidated by performing DNA mobility and binding assays, enzyme inhibition assays, and in vitro oxidative stress studies.

  10. Technetium Behavior and Recovery in Soil

    Energy Technology Data Exchange (ETDEWEB)

    Meinken,G.E.

    1995-12-01

    Technetium-99 in soils is of great concern because of its long half-life and because it can not be detected readily. This work reviews the behavior of technetium in various types of soils. A method for extracting technetium from soil was developed with the use of technetium-95m and 99m to determine recoveries at each step. Technetium chemistry is very complicated and problem areas in the behavior and recovery have been highlighted. Technetium is widely used in nuclear medicine and a review of its chemistry pertaining to radiopharmaceuticals is relevant and helpful in environmental studies. The technetium behavior in the patented citric acid method for the removal of toxic metals in contaminated soils was studied. An innovative method using solid phase extraction media for the concentration of technetium extracted from soils, with water and hydrogen peroxide, was developed. This technique may have a useful environmental application for this type of remediation of technetium from contaminated soils.

  11. Technetium behavior and recovery in soil

    International Nuclear Information System (INIS)

    Meinken, G.E.

    1995-12-01

    Technetium-99 in soils is of great concern because of its long half-life and because it can not be detected readily. This work reviews the behavior of technetium in various types of soils. A method for extracting technetium from soil was developed with the use of technetium-95m and 99m to determine recoveries at each step. Technetium chemistry is very complicated and problem areas in the behavior and recovery have been highlighted. Technetium is widely used in nuclear medicine and a review of its chemistry pertaining to radiopharmaceuticals is relevant and helpful in environmental studies. The technetium behavior in the patented citric acid method for the removal of toxic metals in contaminated soils was studied. An innovative method using solid phase extraction media for the concentration of technetium extracted from soils, with water and hydrogen peroxide, was developed. This technique may have a useful environmental application for this type of remediation of technetium from contaminated

  12. A novel approach towards the synthesis of pyrophosphate analogues of farnesyl pyrophosphate

    NARCIS (Netherlands)

    Valentijn, A.R.P.M.; Berg, O. van den; Marel, G.A. van der; Cohen, L.H.; Boom, J.H. van

    1994-01-01

    The synthesis of two new analogues (i.e. 3 and 4) of farnesyl pyrophosphate (FPP) containing a phosphonophosphate and a phosphonophosphonate moiety was accomplished via the phosphonomorpholidate. The latter was easily obtained by treatment of a phosphonic chloride with morpholine.

  13. Investigating the Role of Global Histogram Equalization Technique for 99mTechnetium-Methylene diphosphonate Bone Scan Image Enhancement.

    Science.gov (United States)

    Pandey, Anil Kumar; Sharma, Param Dev; Dheer, Pankaj; Parida, Girish Kumar; Goyal, Harish; Patel, Chetan; Bal, Chandrashekhar; Kumar, Rakesh

    2017-01-01

    99m Technetium-methylene diphosphonate ( 99m Tc-MDP) bone scan images have limited number of counts per pixel, and hence, they have inferior image quality compared to X-rays. Theoretically, global histogram equalization (GHE) technique can improve the contrast of a given image though practical benefits of doing so have only limited acceptance. In this study, we have investigated the effect of GHE technique for 99m Tc-MDP-bone scan images. A set of 89 low contrast 99m Tc-MDP whole-body bone scan images were included in this study. These images were acquired with parallel hole collimation on Symbia E gamma camera. The images were then processed with histogram equalization technique. The image quality of input and processed images were reviewed by two nuclear medicine physicians on a 5-point scale where score of 1 is for very poor and 5 is for the best image quality. A statistical test was applied to find the significance of difference between the mean scores assigned to input and processed images. This technique improves the contrast of the images; however, oversaturation was noticed in the processed images. Student's t -test was applied, and a statistically significant difference in the input and processed image quality was found at P histogram equalization technique in combination with some other postprocessing technique is useful.

  14. Scintigraphic diagnosis of acute nontransmural myocardial infarction using sup(99m)Tc-labelled pyrophosphate

    Energy Technology Data Exchange (ETDEWEB)

    Duska, F; Novak, J; Vizda, J; Kafka, P; Kubicek, J; Veverkova, O [Karlova Univ., Hradec Kralove (Czechoslovakia). Lekarska Fakulta

    1980-04-01

    In 10 patients with acute non-transmural myocardial lesion, the heart muscle was examined by scintigraphy. The scan was negative in 4 patients, positive in 6. No obvious relationship was observed between the degree and character of sup(99m)Tc-pyrophosphate cumulation in the myocardial lesion and the results of other laboratory tests. The actual site of non-transmural lesion cannot be determined by scan. Although scintigraphy alone cannot decide whether a non-transmural necrosis or mere ischemic heart disease is involved, the method is a valuable addition to other diagnostic techniques presently in use.

  15. Comparison of technetium-99m methoxyisobutylisonitrile and gallium-67 citrate scanning in the assessment of lymphomas

    International Nuclear Information System (INIS)

    Ziegels, P.; Nocaudie, M.; Huglo, D.; Deveaux, M.; Detourmignies, L.; Wattel, E.; Marchandise, X.

    1995-01-01

    The aim of this study was to compare the value of scintigraphy using technetium-99m methoxy-isobutylisonitrile (MIBI) with that of scintigraphy using gallium-67 citrate in the assessment of Hodgkin's disease and non-Hodgkin's lymphoma and to relate these results with those of CT scan and MRI. Fifty-eight patients were included either for a follow-up examination or for monitoring of their treatment. Twenty-three residual masses were studied. A whole-body scan was performed, followed by single-photon emission computed tomography (SPET) 20 min after injection of 740 MBq of 99m Tc-MIBI and 72 h after injection of 185 MBq of 67 Ga citrate. The overall sensitivity of 99m Tc-MIBI and 67 Ga citrate was 71% and 68%, respectively, and the overall specificity was 76% and 44%, respectively. For residual masses, the sensitivity was 44% with both tracers and the specificity was 80% with 99m Tc-MIBI and 53% with 67 Ga citrate. The positive predictive values were 85% and 68% and the negative predictive values were 59% and 44%, respectively. The signal-to-background ratio was 1.5 for 99m Tc-MIBI and 2 for 67 Ga citrate. At present, 99m Tc-MIBI cannot replace 67 Ga citrate in the assessment of lymphomas. (orig.)

  16. Anomalous properties of technetium clusters

    International Nuclear Information System (INIS)

    Kryuchkov, S.V.

    1985-01-01

    On the basis of critical evaluation of literature data in the field of chemistry of technetium cluster compounds with ligands of a weak field a conclusion is made on specific, ''anomalous'' properties of technetium cluster complexes which consist in an increased ability of the given element to the formation of a series of binuclear and multinuclear clusters, similar in composition and structure and easily transforming in each other. The majority of technetium clusters unlike similar compounds of other elements are paramagnetic with one unpaired electron on ''metallic'' MO of loosening type. All theoretical conceptions known today on the electronic structure of technetium clusters are considered. It is pointed out, that the best results in the explanation of ''anomalous'' properties of technetium clusters can be obtained in the framework of nonempirical methods of self-consistent field taking into account configuration interactions. It is also shown, that certain properties of technetium clusters can be explained on the basis of qualitative model of Coulomb repulsion of metal atoms in clusters. The conclusion is made, that technetium position in the Periodic table, as well as recently detected technetium property to the decrease of effective charge on its atoms during M-M bond formation promote a high ability of the element to cluster formation both with weak field ligands and with strong field one

  17. Thermal conductivity of technetium

    International Nuclear Information System (INIS)

    Minato, K.; Serizawa, H.; Fukuda, K.

    1998-01-01

    The thermal diffusivity of technetium was measured on a disk sample of 5 mm in diameter and 1 mm in thickness by the laser flash method from room temperature to 1173 K, and the thermal conductivity was determined by the measured thermal diffusivity and density, and the reported specific heat capacity. The thermal diffusivity of technetium decreases with increasing temperature though it is almost constant above 600 K. The thermal conductivity of technetium shows a minimum around 400 K, above which the thermal conductivity increases with temperature. The electronic and phonon components of the thermal conductivity were evaluated approximately. The increase in the thermal conductivity of technetium with temperature is due to the increase in the electronic component. (orig.)

  18. Familial pyrophosphate arthropathy. Occurrence and Crystal Identification.

    Science.gov (United States)

    Bjelle, A

    1981-01-01

    Hereditary pyrophosphate arthropathy has been observed in three Swedish families and in a few other caucasian populations. The inheritance is most probably autosomal dominant with a variable penetrance. The most severe cases have been found in homozygotes among isolates of immigrants in Slovakia and Chile. Studies on genetic and etio-pathogenetic factors in hereditary pyrophosphate arthropathy, and the utilization of new diagnostic techniques for crystal identification, are important approaches towards a further understanding of the disease.

  19. Controllable Fabrication of Amorphous Co-Ni Pyrophosphates for Tuning Electrochemical Performance in Supercapacitors.

    Science.gov (United States)

    Chen, Chen; Zhang, Ning; He, Yulu; Liang, Bo; Ma, Renzhi; Liu, Xiaohe

    2016-09-07

    Incorporation of two transition metals offers an effective method to enhance the electrochemical performance in supercapacitors for transition metal compound based electrodes. However, such a configuration is seldom concerned in pyrophosphates. Here, amorphous phase Co-Ni pyrophosphates are fabricated as electrodes in supercapacitors. Through controllably adjusting the ratios of Co and Ni as well as the calcination temperature, the electrochemical performance can be tuned. An optimized amorphous Ni-Co pyrophosphate exhibits much higher specific capacitance than monometallic Ni and Co pyrophosphates and shows excellent cycling ability. When employing Ni-Co pyrophosphates as positive electrode and activated carbon as a negative electrode, the fabricated asymmetric supercapacitor cell exhibits favorable capacitance and cycling ability. This study provides facile methods to improve the transition metal pyrophosphate electrodes for efficient electrodes in electrochemical energy storage devices.

  20. Under used technetium-99m generators

    International Nuclear Information System (INIS)

    Mushtaq, A.

    2001-01-01

    Health care reform truly has become a global issue and it will undoubtedly have a dramatic impact on the future of nuclear medicine business in particular. A bigger concern within the nuclear medicine community is its competitiveness with other modalities and cost effectiveness.Technetium-99m and its generators are playing key role for the majority of diagnostic scans performed in the world today. Availability of ''9''9''mTc can be increased if it is separated from ''9''9Mo after much shorter growth times. After proper planning with the extra ''9''9''mTc, a significant number of scans can be performed or we would be able to order approximately 30% low activity ''9''9Tc generators to fulfill our requirements

  1. Preparation of cerium doped calcium pyrophosphate: Study of luminescent behavior

    Energy Technology Data Exchange (ETDEWEB)

    Lozano, I.B., E-mail: ivonne.berenice@gmail.com [Instituto Politécnico Nacional, Centro de Investigación en Ciencia Aplicada y Tecnología Avanzada, Unidad Legaria, 11500 México D.F., México (Mexico); Roman-Lopez, J. [CONACYT Research Fellow-Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México, A.P. 70-543, 04510 México D.F., México (Mexico); Sosa, R. [Departamento de Física, Universidad Autónoma Metropolitana-Iztapalapa, 09340 México D.F., México (Mexico); Díaz-Góngora, J.A.I [Instituto Politécnico Nacional, Centro de Investigación en Ciencia Aplicada y Tecnología Avanzada, Unidad Legaria, 11500 México D.F., México (Mexico); Azorín, J. [Departamento de Física, Universidad Autónoma Metropolitana-Iztapalapa, 09340 México D.F., México (Mexico)

    2016-05-15

    Thermoluminescent (TL) and photoluminescent (PL) band emissions of cerium doped calcium pyrophosphate (Ca{sub 2}O{sub 7}P{sub 2}:Ce{sup 3+}) were studied. Wet precipitation method was used to synthesize calcium pyrophosphate, doped with Ce{sup 3+} (1.0 at%) impurities, from orthophosphoric acid and calcium acetate, as raw materials. The effect of temperature annealing at 800 and 900 °C was investigated. X-Ray diffraction (XRD) and Scanning Electron Microscope (SEM) were used to characterize both as-precipitated and annealed powders samples. The PL emission spectrum of samples annealed at 900 °C displayed characteristics 5d–4f transitions of Ce{sup 3+} at 333 nm and 360 nm. TL measurements were carried out on as-precipitated and annealed samples from room temperature (RT) up to 350 °C. The TL results of annealed samples showed complex TL glow curves, a linear response in the absorbed dose range of 0.5–5 Gy and a good reproducibility after 10 cycles of irradiation-readout. The complex TL glow curves of annealed samples were analyzed by the methods of T{sub max}–T{sub Stop}, Initial Rise (IR) and Computational Glow-Curve Deconvolution (CGCD) assuming a General Order Kinetic (GOK).

  2. Behaviour of technetium in marine algae

    International Nuclear Information System (INIS)

    Bonotto, S.; Kirchmann, R.; Van Baelen, J.; Hurtger, C.; Cogneau, M.; Van der Ben, D.; Verthe, C.; Bouquegneau, J.M.

    1985-01-01

    Uptake and distribution of technetium were studied in several green (Acetabularia acetabulum, Boergesenia forbesii, Ulva lactuca) and brown (Ascophyllum nodosum, Fucus serratus, Fucus spiralis and Fucus vesiculosus) marine algae. Technetium was supplied to the algae as Tc-95m-pertechnetate. Under laboratory conditions, the algae were capable of accumulating technetium, with the exception, however, of Boergesenia, which showed concentration factors (C.F.) comprised between 0.28 and 0.71. The concentration of technetium-99 in Fucus spiralis, collected along the Belgian coast, was measured by a radiochemical procedure. The intracellular distribution of technetium was studied by differential centrifugation in Acetabularia and by the puncturing technique in Boergesenia. The chemical forms of technetium penetrated into the cells were investigated by selective chemical extractions, molecular sieving and thin layer chromatography

  3. Behaviour of technetium in marine algae

    International Nuclear Information System (INIS)

    Bonotto, S.; Kirchmann, R.; Baelen, J. van; Hurtgen, C.; Cogneau, M.; Ben, D. van der; Verthe, C.; Bouquegneau, J.M.

    1986-01-01

    Uptake and distribution of technetium were studied in several green (Acetabularia acetabulum, Boergesenia forbesii, Ulva lactuca) and brown (Ascophyllum nodosum, Fucus serratus, Fucus spiralis and Fucus vesiculosus) marine algae. Technetium was supplied to the algae as Tc-95-pertechnetate. Under laboratory conditions, the algae were capable of accumulating technetium, with the exception, however, of Boergesenia, which showed concentration factors (C.F.) comprised between 0.28 and 0.71. The concentration of technetium-99 in Fucus spiralis, collected along the Belgian coast, was measured by a radiochemical procedure. The intracellular distribution of technetium was studied by differential centrifugation in Acetabularia and by the puncturing technique in Boergesenia. The chemical forms of technetium penetrated into the cells were investigated by selective chemical extractions, molecular sieving and thin layer chromatography. (author)

  4. Expression, crystallization and preliminary crystallographic study of octaprenyl pyrophosphate synthase from Helicobacter pylori

    International Nuclear Information System (INIS)

    Zhang, Jinyong; Zhang, Xiaoli; Mao, Xuhu; Zou, Quanming; Li, Defeng

    2011-01-01

    Octaprenyl pyrophosphate synthase from H. pylori has been expressed, purified and crystallized, and a diffraction data set was collected to 2.00 Å resolution. Octaprenyl pyrophosphate synthase (OPPs) is involved in the synthesis of the side chains of ubiquinone and menaquinone and catalyzes consecutive condensation reactions of farnesyl pyrophosphate with isopentenyl pyrophosphate to generate polyprenyl pyrophosphate and pyrophosphate. In order to investigate the roles played by OPPs in the metabolism of ubiquinone and menaquinone and the enzymatic mechanisms of these enzymes, analysis of the structure–function relationship of OPPs from Helicobacter pylori was initiated. The gene for OPPs was cloned, the protein was expressed, purified and crystallized and a diffraction data set was collected to 2.00 Å resolution. The crystals belonged to space group P4 1 2 1 2 or P4 3 2 1 2, with unit-cell parameters a = b = 109.33, c = 103.41 Å

  5. Extraosseous uptake of 99sup(m)technetium methylene diphosphonate

    International Nuclear Information System (INIS)

    Sty, J.R.; Kun, L.; Casper, J.; Babbitt, D.P.

    1980-01-01

    A child with a ganglioneuroblastoma and tumor uptake of 99 sup(m)technetium methylene diphosphate ( 99 sup(m)Tc-MDP) is presented. After surgical removal of an encapsulated tumor and radiation therapy, an interval bone scan demonstrated the same presurgical abnormality. Awareness of abnormal uptake of 99 sup(m)Tc-MDP in irradiated renal tissue prevents interpreting radiation nephritis as recurrent tumor. (orig.) [de

  6. Stabilized radiographic scanning agent

    International Nuclear Information System (INIS)

    Fawzi, M.B.

    1979-01-01

    A stable composition useful in preparation of technetium-99m-based radiographic scanning agents has been developed. The composition contains a stabilizing amount of gentisate stabilizer selected from gentisic acid and its soluble pharmaceutically-acceptable salts and esthers. (E.G.)

  7. In Silico-Based Repositioning of Phosphinothricin as a Novel Technetium-99m Imaging Probe with Potential Anti-Cancer Activity.

    Science.gov (United States)

    Sakr, Tamer M; Khedr, Mohammed A; Rashed, Hassan M; Mohamed, Maged E

    2018-02-23

    l-Phosphinothricin (glufosinate or 2-amino-4-((hydroxy(methyl) phosphinyl) butyric acid ammonium salt (AHPB)), which is a structural analog of glutamate, is a recognized herbicide that acts on weeds through inhibition of glutamine synthetase. Due to the structural similarity between phosphinothricin and some bisphosphonates (BPs), this study focuses on investigating the possibility of repurposing phosphinothricin as a bisphosphonate analogue, particularly in two medicine-related activities: image probing and as an anti-cancer drug. As BP is a competitive inhibitor of human farnesyl pyrophosphate synthase (HFPPS), in silico molecular docking and dynamic simulations studies were established to evaluate the binding and stability of phosphinothricin with HFPPS, while the results showed good binding and stability in the active site of the enzyme in relation to alendronate. For the purpose of inspecting bone-tissue accumulation of phosphinothricin, a technetium ( 99m Tc)-phosphinothricin complex was developed and its stability and tissue distribution were scrutinized. The radioactive complex showed rapid, high and sustained uptake into bone tissues. Finally, the cytotoxic activity of phosphinothricin was tested against breast and lung cancer cells, with the results indicating cytotoxic activity in relation to alendronate. All the above results provide support for the use of phosphinothricin as a potential anti-cancer drug and of its technetium complex as an imaging probe.

  8. Technetium migration in natural clays; Migration von Technetium in natuerlichem Tongestein

    Energy Technology Data Exchange (ETDEWEB)

    Luebke, Maria

    2015-10-01

    The present work was performed within the joint research project ''Retention of repository relevant radionuclides in argillaceous rocks and saline systems'' (contract no.: 02E10981), funded by the Federal Ministry for Economic Affairs and Energy (BMWi). The aim was to obtain first insights into the interaction of the long-lived fission product technetium and natural clay with regard to a repository for high-level nuclear waste. For this purpose Opalinus Clay from Mont Terri (northern Switzerland) was used as a reference material. The nuclide technetium-99 will contribute to the radiotoxicity of spent nuclear fuel for more than thousand years due to its long half-live. In case of a leakage of the storage vessels, the geochemistry of technetium is determined by its oxidation state, at which only the oxidation states +IV and +VII are relevant. Because of the high solubility and low affinity to sorption on surfaces of minerals, Tc(VII) is considered to be very mobile and thus the most hazardous species. The focuses of this study therefore are diffusion experiments with this mobile species and investigations of the effect of ferrous iron on the mobility and speciation of technetium.rnThe interaction of technetium and Opalinus Clay was studied in sorption and diffusion experiments varying several parameters (pH value, addition of reducing agents, effect of oxygen, diffusion pathways). In the course of this study spatially resolved investigations of the speciation have been performed on Opalinus Clay thin sections and bore cores for the first time. In addition to the speciation, further information regarding elemental distributions and crystalline phases near technetium enrichments were obtained. Supplementary investigations of powder samples allowed determining the molecular structure of technetium on the clay surface.rnBoth the combination of sorption experiments with spectroscopic investigations and the diffusion experiment exhibit a reduction of Tc

  9. Technetium-99m pyrophosphate scintigraphy for the detection of acute myocardial infarction. How useful is it

    International Nuclear Information System (INIS)

    Desai, A.G.; Berger, B.C.; Shin, Y.W.; Park, C.H.; Madsen, M.T.

    1985-01-01

    To evaluate the contribution of Tc-99m pyrophosphate scintigraphy (TPS) on the overall management of patients suspected of having acute myocardial infarction (AMI), hospital records of 58 consecutive patients who underwent TPS, were evaluated in depth. The results indicate that TPS was essential for the diagnosis of AMI in 16% of the patients. TPS was most rewarding in perioperative patients and in patients with borderline or uninterpretable electrocardiographic and enzyme changes. Also, in some cases, TPS was able to confirm or exclude the diagnosis of AMI prior to the confirmation by serial electrocardiograms (ECG) and serial enzyme changes. TPS was less rewarding in patients with clinically low index of suspicion for AMI. It may also be confusing in patients with high clinical likelihood of AMI and a history of prior myocardial infarction because of the possibility of persistently positive TPS in some of these patients. Considering the limitations of ECGs, the cardiac enzymes, and atypical clinical presentations in the patient population we evaluated, TPS appears to be fairly accurate when the scintigraphic findings are compared with the final diagnosis at the time of discharge from the hospital

  10. Methanophosphagen: Unique cyclic pyrophosphate isolated from Methanobacterium thermoautotrophicum

    OpenAIRE

    Kanodia, Sushila; Roberts, Mary Fedarko

    1983-01-01

    A unique cyclic pyrophosphate compound has been detected at 10-12 mM intracellular concentration in Methanobacterium thermoautotrophicum by in vivo31P NMR. This compound has been extracted from cells and purified by anion-exchange chromatography. Studies with 1H, 13C, and 31P NMR and fast-atom-bombardment mass spectrometry have identified it as 2,3-cyclopyrophosphoglycerate, an intramolecularly cyclized pyrophosphate of 2,3-diphosphoglycerate. Chemical degradation to 2,3-diphosphoglycerate an...

  11. Technetium accumulation, fate, and behavior in plants

    International Nuclear Information System (INIS)

    Cataldo, D.A.; Wildung, R.E.; Garland, T.R.

    1978-01-01

    Technetium, a product of the nuclear fuel cycle, is highly soluble in water and mobile in soils as the pertechnetate ion (TcO - 4 ). Soluble ions in soil have the potential for competing with nutrient ions for membrane carrier sites involved in ion uptake by plants. A study was, therefore, undertaken to determine the availability, toxicity, and mechanism of pertechnetate uptake by soybean (Glycine max cv. Williams). Technetium was effectively accumulated by plants at soil concentrations of 0.01 to 0.1 μg/g and in nutrient culture at levels as low as 0.02 pg/ml. Plants grown on soils containing technetium at levels below 0.1 μg/g effectively removed up to 90% of the technetium from soil. Minimal mobilization of technetium from vegetative tissues to the seed occurred during senescence. Chemical analyses indicated that the xylem-mobile form of technetium was TcO 4 - . The uptake rate of technetium by intact plants was multiphasic over the concentration range of 0.01 to 10μM; this suggests active uptake and a specificity for technetium in the root absorption process. Because of the efficiency of technetium accumulation and the probability of its chemical toxicity, competition kinetic studies were undertaken to identify possible nutrient analogs. Nutrients effective in reducing technetium uptake included the Mn 2+ , SO 4 2- , H 2 PO 4 - , and MoO 4 2- ions

  12. Detection of metastatic bone cancer by scintiscanning with sup(99m)Tc labelled sodium pyrophosphate

    International Nuclear Information System (INIS)

    Kromer, Bernard.

    1973-01-01

    Bone scanning with sup(99m)Tc sodium pyrophosphate was performed in 65 patients with primary neoplasms, using a gamma-camera. The scans are compared to those obtained with 85 Sr and 87 Sr. Sup(99m)Tc appears to be superior to the other two in the detection of metastatic bone lesions, mainly because of its physical characteristics (high yield of 140 KeV photons, short physical half-life). The advantages related to these characteristics are emphasized: possibility of rapid and systematic investigation of the whole skeleton using a gamma-camera; low dose irradiation of the patient which enables frequent repetitive studies to be performed [fr

  13. Calcium pyrophosphate dihydrate crystal deposition disease presenting as a pseudotumor of the temporomandibular joint

    International Nuclear Information System (INIS)

    Vargas, A.; Teruel, J.; Pont, J.; Velayos, A.; Trull, J.; Lopez, E.

    1997-01-01

    We report a case of a 66-year-old white woman with calcium pyrophosphate dihydrate (CPPD) crystal deposition disease. The patient related a 2-month history of swelling with tenderness over the left pre-auricular region. A CT scan suggested a synovial chondromatosis. Surgical removal was done and histologic study showed CPPD crystals. This disease rarely involves the temporomandibular joint (TMJ) and is not usually considered in the differential diagnosis. To our knowledge, only 14 cases have been reported in the literature. (orig.)

  14. Technetium compounds and their field of application

    International Nuclear Information System (INIS)

    Zaitseva, L.L.; Velichko, A.V.; Vinogradov, I.V.

    1988-02-01

    This chapter reviews the different applications of technetium and technetium compounds in catalysis, corrosion inhibition, superconductivity of technetium alloys, diagnostic techniques, radioisotope generators and radiopharmaceuticals. 649 refs [fr

  15. Sorption of radionuclide technetium on minerals

    International Nuclear Information System (INIS)

    Li Min; Fan Xianhua; Wei Liansheng; Zhang Yingjie; Jiao Haiyang

    2004-01-01

    The study on adsorption behavior of technetium on antimonial minerals is performed in batch experiments and the influence of adsorption time, mineral granularity, solid-liquid ratio, initial concentration, pH value and reducing ion. On technetium adsorption are considered according to adsorption ratios of hepta valent and quadrivalent technetium on stibnite and antimony ocher, the results show that reduction of technetium from heptavelence to quadrivalence could improve adsorption ratios, which provide reference data for selecting buffer-backfill materials in high level rad waste deep geological diplosal. (author)

  16. Myocardial contusion following nonfatal blunt chest trauma

    International Nuclear Information System (INIS)

    Kumar, S.A.; Puri, V.K.; Mittal, V.K.; Cortez, J.

    1983-01-01

    Currently available diagnostic techniques for myocardial contusion following blunt chest trauma were evaluated. We investigated 30 patients prospectively over a period of 1 year for the presence of myocardial contusion. Among the 30 patients, eight were found to have myocardial contusion on the basis of abnormal electrocardiograms, elevated creatine phosphokinase MB fraction (CPK-MB), and positive myocardial scan. Myocardial scan was positive in seven of eight patients (87.5%). CPK-MB fraction was elevated in four of eight patients (50%). Definitive electrocardiographic changes were seen in only two of eight patients (25%). It appears that myocardial scan using technetium pyrophosphate and CPK-MB fraction determinations are the most reliable aids in diagnosis of myocardial contusion following blunt chest trauma

  17. Radionuclide Basics: Technetium-99

    Science.gov (United States)

    Technetium-99 (chemical symbol Tc-99) is a silver-gray, radioactive metal. It occurs naturally in very small amounts in the earth's crust, but is primarily man-made. Technetium-99m is a short-lived form of Tc-99 that is used as a medical diagnostic tool.

  18. Recovery of technetium from nuclear fuel wastes

    International Nuclear Information System (INIS)

    Carlin, W.W.

    1975-01-01

    Technetium is removed from aqueous, acidic waste solutions. The acidic waste solution is mixed with a flocculant, e.g., an alkaline earth metal hydroxide or oxide, to precipitate certain fission products. Technetium remains in solution and in the resulting supernatant alkaline aqueous phase. The supernatant alkaline aqueous phase is made acidic and electrolyzed in an electrolytic cell under controlled cathodic potential conditions to deposit technetium on the cathode. Elemental technetium is removed from the cathode. Technetium is separated from other plated fission product metals by extraction from an alkaline solution with an organic extractant, such as pyridine, having affinity for technetium. Technetium is separated from the organic extractant by steam distillation and the resulting aqueous phase treated with ammoniacal reagent to precipitate technetium as ammonium pertechnetate. The precipitate may be acidified to form an aqueous acidic solution of fission product metal values and the solution electrolyzed in an electrolytic cell under controlled cathodic potential conditions and at a potential sufficiently negative to plate out from the solution those fission product metals desired. The metal deposit is stripped from the cathode and stored until its radioactivity has diminished. (U.S.)

  19. Technetium-99m Sestamibi in Multiple Myeloma

    International Nuclear Information System (INIS)

    Saber, R.A.

    2002-01-01

    Technetium-99m 2-methoxy - isobutyl - isonitrile (99mTc-MIBI) has been reported to be useful in evaluating patients with multiple myeloma. The aim of this study is to evaluate the role of technetium-99m sestamibi (99mTc-MIBI) scintigraphy in the diagnosis. staging and follow-up of patients with multiple myeloma. Methods and Materials: twenty-five consecutive patients with multiple myeloma were studied using 99mTc- MIBI. Of the 25 patients included in this study, 6 were in stage I, II in stage II and 8 in stage III. Anterior and posterior whole-body imaging were obtained 20 min after I.V. injection of 740 MBq of 99mTc-MIBI. Four different MIBI patterns could be described in our patients: physiological (P), diffuse (D), focal (F) and combined diffuse and focal (D+F). All patients in stages II and III as well as 3 patients in stage I were treated with chemotherapy (cyclophosphamide and prednisone) then 99mTc-MlBI scans were repeated after 6 courses. Results: in comparison to conventional X-ray skeletal survey, 99mTc-MIBI scans showed a higher number of myeloma bone disease at diagnosis. All patients with stage II and III multiple myeloma were positive with 99mTc-MlBl scans at diagnosis. The pattern of positive MIBI accumulation was diffuse in 13 (52%) patients, focal in 4 (16%) and combined focal and diffuse in 6 (24%) patients. The intensity of 99mTc-MIBI correlated with disease activity as determined by lactate dehydrogenase (LDH), number of plasma cells in bone marrow and serum electrophoresis. There was a direct correlation between 99mTc-MIBI scan result and clinical outcome of patients following 6 courses of chemotherapy. Sensitivity and specificity of 99mTc-MIBI scintigraphy in detecting myeloma bone lesions were 92% and 90% respectively. Conclusion: 99mTc-MIBI scintigraphy is a reliable method to evaluate bone marrow activity in patients with multiple myeloma and follow-up of myeloma bone lesions

  20. Pyrophosphate-Inhibition of Apatite Formation Studied by In Situ X-Ray Diffraction

    Directory of Open Access Journals (Sweden)

    Casper Jon Steenberg Ibsen

    2018-02-01

    Full Text Available The pathways to crystals are still under debate, especially for materials relevant to biomineralization, such as calcium phosphate apatite known from bone and teeth. Pyrophosphate is widely used in biology to control apatite formation since it is a potent inhibitor of apatite crystallization. The impacts of pyrophosphate on apatite formation and crystallization kinetics are, however, not fully understood. Therefore, we studied apatite crystallization in water by synchrotron in situ X-ray diffraction. Crystallization was conducted from calcium chloride (0.2 M and sodium phosphate (0.12 M at pH 12 where hydrogen phosphate is the dominant phosphate species and at 60 °C to allow the synchrotron measurements to be conducted in a timely fashion. Following the formation of an initial amorphous phase, needle shaped crystals formed that had an octacalcium phosphate-like composition, but were too small to display the full 3D periodic structure of octacalcium phosphate. At later growth stages the crystals became apatitic, as revealed by changes in the lattice constant and calcium content. Pyrophosphate strongly inhibited nucleation of apatite and increased the onset of crystallization from minute to hour time scales. Pyrophosphate also reduced the rate of growth. Furthermore, when the pyrophosphate concentration exceeded ~1% of the calcium concentration, the resultant crystals had reduced size anisotropy suggesting that pyrophosphate interacts in a site-specific manner with the formation of apatite crystals.

  1. Electrochemistry of technetium

    International Nuclear Information System (INIS)

    Russell, C.D.; Alabama Univ., Birmingham

    1982-01-01

    Recent work on the electrochemistry of technetium is reviewed, covering the period 1973-1980. Topics include polarographic studies of aqueous pertechnetate, coulometric studies of aqueous pertechnetate at mercury cathodes, and electrochemistry of pertechnetate at solid electrodes. A review is also given of electrochemistry of other technetium compounds, non-aqueous systems, chemical redox reactions, and substitution reactions. Consideration is also given to studies of electrochemistry at tracer concentrations, electrolytic syntheses, standard electrode potentials, and electroanalytical methods. (author)

  2. Sample preparation and characterization of technetium metal

    International Nuclear Information System (INIS)

    Minato, Kazuo; Serizawa, Hiroyuki; Fukuda, Kousaku; Itoh, Mitsuo

    1997-10-01

    Technetium-99 is a long-lived fission product with a half-life of about 2.1 x 10 5 years, which decays by β-emission. For the transmutation of 99 Tc, research on solid technetium was started. Technetium metal powder purchased was analyzed by X-ray diffraction, γ-ray spectrometry, and inductively coupled plasma-atomic emission spectrometry and -mass spectrometry. The lattice parameters obtained were agreed with the reported values. The metallic impurity was about 15 ppm, where aluminum and iron contributed mainly. No impurity nuclide with γ-emission was found. Using the technetium metal powder, button-, rod-, and disk-shaped samples of technetium metal were prepared by arc-melting technique. Thermal diffusivity of technetium metal was measured on a disk sample from room temperature to 1173 K by laser flash method. The thermal diffusivity decreased with increasing temperature though it was almost constant above 600 K. (author)

  3. Inositol pyrophosphates promote tumor growth and metastasis by antagonizing liver kinase B1

    OpenAIRE

    Rao, Feng; Xu, Jing; Fu, Chenglai; Cha, Jiyoung Y.; Gadalla, Moataz M.; Xu, Risheng; Barrow, James C.; Snyder, Solomon H.

    2015-01-01

    Inositol pyrophosphates are messenger molecules incorporating the energetic pyrophosphate bond. Although they have been implicated in diverse biologic processes, their physiologic functions remain enigmatic. We show that the catalytic activity of inositol hexakisphosphate kinase 2 (IP6K2), one of the principal enzymes generating the inositol pyrophosphate IP7 (5-diphosphoinositolpentakisphosphate), mediates cancer cell migration and tumor metastasis both in cell culture and intact mice. In th...

  4. Method of quantification of bone scintigraphy using technetium labelled stannous pyrophosphate. Results concerning 882 whole-body scintigraphy

    International Nuclear Information System (INIS)

    Chedeville, Rene.

    1976-01-01

    Considerable progress was made in isotope bone imaging with strontium 85 after the principle of quantification was introduced by Rosenthall in 1965. In 1971, Subramanian and McAffee reported that excellent visualization could be obtained with polyphosphates labelled with sup(99m)Tc. In the present study, imaging was performed 4 hours after injection of sup(99m)Tc pyrophosphate. An Elscint dual head wole body scanner and a VDP 2 off-line calculator were used. Counts were collected over selected regions of interest, each measuring 4.5 x 3.5 cm, and over the whole body. After checking reproducibility by double counting (SD of the mean = 15%), two methods of quantification were studied, the counts being expressed as: the ratio of the number of counts in the bone segment to the number of counts in the knee, the ratio of the number of counts in the bone segment/the number of counts in the whole body. In these operations, the whole body count was multiplied by 2.10 -3 in order to have a ratio whole body count.2.10 -3 /knee = 1. The ratios calculated from the different bone diseases under study were then compared [fr

  5. Determination of technetium-99 in environmental and radioactive waste samples

    International Nuclear Information System (INIS)

    Ferencova, M.; Peter Tkac, P.

    2007-01-01

    Technetium is known for its high mobility in a soil-water system in non-reducing aerobic condition and also high bio-availability for plants, because the most stable form of technetium in natural surface environment is pertechnetate which is highly soluble. The chemical form of technetium changes with environmental conditions. Concentration of technetium in the environment is very low, therefore many separation steps are needed for technetium determination. It has been developed a method for the routine determination of technetium-99 from environmental matrices and radioactive wastes using technetium-99m as an internal yield monitor. Technetium-99 is extracted from the soil samples with nitric acid. Many contaminants are co-precipitated with ferric hydroxide and technetium in the supernatant is pre-concentrated and further purified using anion exchange chromatography. Final separation of technetium was achieved by extraction with tetraphenylarsonium chloride in chloroform from sulphuric acid or pure water. The chemical yield is determined through the measurement of technetium-99m by scintillation counting system and the technetium-99 activity is measured using proportional counter after decay of the technetium-99m activity. Typical recoveries for this method are in the order 50-60 % (authors)

  6. In Silico-Based Repositioning of Phosphinothricin as a Novel Technetium-99m Imaging Probe with Potential Anti-Cancer Activity

    Directory of Open Access Journals (Sweden)

    Tamer M. Sakr

    2018-02-01

    Full Text Available l-Phosphinothricin (glufosinate or 2-amino-4-((hydroxy(methyl phosphinyl butyric acid ammonium salt (AHPB, which is a structural analog of glutamate, is a recognized herbicide that acts on weeds through inhibition of glutamine synthetase. Due to the structural similarity between phosphinothricin and some bisphosphonates (BPs, this study focuses on investigating the possibility of repurposing phosphinothricin as a bisphosphonate analogue, particularly in two medicine-related activities: image probing and as an anti-cancer drug. As BP is a competitive inhibitor of human farnesyl pyrophosphate synthase (HFPPS, in silico molecular docking and dynamic simulations studies were established to evaluate the binding and stability of phosphinothricin with HFPPS, while the results showed good binding and stability in the active site of the enzyme in relation to alendronate. For the purpose of inspecting bone-tissue accumulation of phosphinothricin, a technetium (99mTc–phosphinothricin complex was developed and its stability and tissue distribution were scrutinized. The radioactive complex showed rapid, high and sustained uptake into bone tissues. Finally, the cytotoxic activity of phosphinothricin was tested against breast and lung cancer cells, with the results indicating cytotoxic activity in relation to alendronate. All the above results provide support for the use of phosphinothricin as a potential anti-cancer drug and of its technetium complex as an imaging probe.

  7. Study of sorption of technetium on pyrrhotine

    International Nuclear Information System (INIS)

    Shen Dong; Fan Xianhua; Su Xiguang; Zeng Jishu

    2001-01-01

    The sorption behaviors of technetium on pyrrhotine are studied with batch experiment and dilute sulfuric acid is used to dissolve the technetium adsorbed on pyrrhotine. Sorption and desorption experiment are performed under aerobic and anaerobic conditions (inert gas box). The results show that a significant sorption of technetium on pyrrhotine is found under aerobic and anaerobic conditions, and the sorption on the mineral is supposed to be due to the reduction of TcO 4 - to insoluble TcO 2 ·nH 2 O. Desorption process of the sorbed technetium into dilute sulfuric acid is found to be different under aerobic and anaerobic conditions. On addition of H 2 O 2 to the leach solution a sudden increase of the technetium concentration is observed

  8. Final Report Technetium Monitor

    International Nuclear Information System (INIS)

    Spencer, W.A.

    2003-01-01

    The Hanford River Protection Project Waste Treatment Plant (WTP) is required by the current contract to remove radioactive technetium FR-om stored caustic nuclear waste solutions. The Savannah River Technology Center (SRTC) has worked with typical envelopes of these wastes to optimize the removal process. To support the studies, SRTC developed a rapid on-line remote analyzer to monitor technetium and rhenium levels in solutions as well as track other metals in the solutions through the process operations. Rhenium was used as a non-radioactive substitute for technetium in process development studies. The remote monitor was based on inductively coupled plasma emission spectroscopy (ICPES). Fiber optic cable and extended RF cabling removed the plasma source FR-om the spectrometer and instrument electronics

  9. Search for technetium in natural tin metallurgical residues

    Energy Technology Data Exchange (ETDEWEB)

    Parker, C.W.

    1996-07-01

    Possible instability of baryons inside the nuclei might result in accumulation of rare isotopes in natural ores. In this respect, isotopes of technetium have certain advantages that can be useful in the search for technetium in nonradioactive ores by chemical methods. In this paper, we review the history of technetium research and discuss a new approach to the search for natural technetium associated with tin ores which appears to offer a rare possibility of discovering a smelting operation by-product such as flue dust, in which the volatile technetium heptoxide (Tc{sub 2}O{sub 7}), like rhenium heptoxide (Re{sub 2}O{sub 7}), would be expected to concentrate. Our concept of a search for technetium in these materials would be based on the assumption that traces of rhenium could occur in the ore and could be traced most easily by neutron activation of small samples. Such a procedure would confirm that an enrichment from the ore to the flue dust actually occurs with the rhenium and therefore should occur with technetium. Furthermore, this occurrence should identify the best location to search for technetium.

  10. Technetium recovery from high alkaline solution

    Energy Technology Data Exchange (ETDEWEB)

    Nash, Charles A.

    2016-07-12

    Disclosed are methods for recovering technetium from a highly alkaline solution. The highly alkaline solution can be a liquid waste solution from a nuclear waste processing system. Methods can include combining the solution with a reductant capable of reducing technetium at the high pH of the solution and adding to or forming in the solution an adsorbent capable of adsorbing the precipitated technetium at the high pH of the solution.

  11. Prediction of chemotherapy response in untreated malignant lymphomas using technetium-99m methoxyisobutylisonitrile scan. Comparison with P-glycoprotein expression and other prognostic factors. A preliminary report

    International Nuclear Information System (INIS)

    Liang, Ji-An; Yang, Shih-Neng; Lin, Fang-Jen; Kao, Albert; Lee, Cheng-Chun; Shiau, Yu-Chien

    2002-01-01

    The purpose of this study was to predict chemotherapy response in untreated malignant lymphomas using technetium-99m methoxyisobutylisonitrile (Tc-MIBI) scan. Twenty-five patients with malignant lymphoma were studied before receiving chemotherapy. Early Tc-MIBI scan was performed 10 min after intravenous injection of Tc-MIBI. Immunohistochemical analyses were performed on multiple non-consecutive sections of the biopsy specimens to determine Pgp expression. Chemotherapy response was evaluated in the first 1-2 years after completion of treatment by clinical and radiological methods. The mean tumor-to-background ratio of the 15 patients with good response (3.3±0.6) was significantly higher than that of the 10 patients with poor response (1.2±0.1). Among the 15 patients with good response to chemotherapy, all had positive Tc-MIBI scan results but negative Pgp expression. Among the 10 patients who had poor response to chemotherapy, all 10 had negative Tc-MIBI scan, but six patients had positive Pgp expression and four had negative Pgp expression. Significant differences were found in the incidences of good and poor responses determined by Tc-MIBI scan and Pgp expression. However, there were no significant differences in the incidences of good and poor responses for other prognostic factors. Compared with other prognostic factors, early Tc-MIBI scan more accurately predicts chemotherapy response in patients with malignant lymphoma. (author)

  12. Sorption of radioactive technetium on pyrrhotine

    International Nuclear Information System (INIS)

    Shen, D.; Fan, X.H.; Su, X.G.; Zeng, J.S.; Dong, Y.

    2002-01-01

    The sorption behavior of technetium on pyrrhotine was studied with batch experiments and diluted sulfuric acid (less than 2.88 mol/l) was used to dissolve the technetium adsorbed on pyrrhotine. A significant sorption of technetium on pyrrhotine was observed under aerobic and anaerobic conditions, and the sorption on the mineral was supposed to be due to the reduction of TcO 4 - to insoluble TcO 2 x nH 2 O. Sorbed technetium on the mineral could be desorbed by diluted sulfuric acid. The maximum desorption ratio under aerobic conditions was much higher than that of under anaerobic conditions, meanwhile, the desorption rates under anaerobic conditions were higher than that of under aerobic conditions in the initial stage of the experiments. (author)

  13. Biosynthesis of monoterpenes: Stereochemistry of the coupled isomerization and cyclization of geranyl pyrophosphate to camphane and isocamphane monoterpenes

    International Nuclear Information System (INIS)

    Croteau, R.; Gershenzon, J.; Wheeler, C.J.; Satterwhite, D.M.

    1990-01-01

    The conversion of geranyl pyrophosphate to (+)-bornyl pyrophosphate and (+)-camphene is considered to proceed by the initial isomerization of the substrate to (-)-(3R)-linalyl pyrophosphate and the subsequent cyclization of this bound intermediate. In the case of (-)-bornyl pyrophosphate and (-)-camphene, isomerization of the substrate to the (+)-(3S)-linalyl intermediate precedes cyclization. The geranyl and linalyl precursors were shown to be mutually competitive substrates (inhibitors) of the relevant cyclization enzymes isolated from Salvia officinalis (sage) and Tanacetum vulgare (tansy) by the mixed substrate analysis method, demonstrating that isomerization and cyclization take place at the same active site. Incubation of partially purified enzyme preparations with (3R)-[1Z-3H]linalyl pyrophosphate plus [1-14C]geranyl pyrophosphate gave rise to double-labeled (+)-bornyl pyrophosphate and (+)-camphene, whereas incubation of enzyme preparations catalyzing the antipodal cyclizations with (3S)-[1Z-3H]-linalyl pyrophosphate plus [1-14C]geranyl pyrophosphate yielded double-labeled (-)-bornyl pyrophosphate and (-)-camphene. Each product was then transformed to the corresponding (+)- or (-)-camphor without change in the 3H:14C isotope ratio, and the location of the tritium label was deduced in each case by stereoselective, base-catalyzed exchange of the exo-alpha-hydrogen of the derived ketone. The finding that the 1Z-3H of the linalyl precursor was positioned at the endo-alpha-hydrogen of the corresponding camphor in all cases, coupled to the previously demonstrated retention of configuration at C1 of the geranyl substrate in these transformations, confirmed the syn-isomerization of geranyl pyrophosphate to linalyl pyrophosphate and the cyclization of the latter via the anti,endo- conformer

  14. Method of producing radioactive technetium-99M

    International Nuclear Information System (INIS)

    Karageozian, H.L.

    1979-01-01

    A chromatographic process of producing high purity and high yield radioactive Technetium-99m. A solution containing Molybdenum-99m and Technetium-99m is placed on a chromatographic column and eluted with a neutral solvent system comprising an organic solvent and from about 0.1 to less than about 10% of water or from about 1 to less than about 70% of a solvent selected from the group consisting of aliphatic alcohols having 1 to 6 carbon atoms. The eluted solvent system containing the Technetium-99m is then removed leaving the Technetium-99m as a dry, particulate residue

  15. Technetium in the geologic environment - a literature survey

    International Nuclear Information System (INIS)

    Torstenfelt, B.; Allard, B.; Andersson, K.; Olofsson, U.

    1981-07-01

    The authors present a literature survey of technetium, discussing, in particular, the oxidation states, the chemistry of technetium in connection with spent nuclear fuel storage, the sorption of technetium in rock, clay, soil and sea bottom sediments. (G.T.H.)

  16. Chemistry and structure of technetium complexes

    International Nuclear Information System (INIS)

    Baldas, J.; Boas, J.F.; Bonnyman, J.; Williams, G.A.

    1983-01-01

    The structures of tris(2-aminobenzenethiolato) technetium(VI) and dichlorobis(diethyldithiocarbamato) thionitrosyltechnetium(V) have been determined by single crystal x-ray diffraction analysis. The preparation and chemistry of thiocyanato complexes of technetium have been investigated

  17. Increased technetium-99 m hydroxy diphosphonate soft tissue uptake on bone scintigraphy in chronic kidney disease patients with secondary hyperparathyroidism

    DEFF Research Database (Denmark)

    Enevoldsen, Lotte Hahn; Heaf, James Goya; Højgaard, Liselotte

    2017-01-01

    In bone scan patients with dialysis-treated chronic kidney disease (CKD) and hyperparathyroidism, soft tissue accumulation of technetium-99 m hydroxy/methylene diphosphonate (Tc-99 m-HDP/MDP) has been reported primarily in case reports and usually explained by hypercalcaemia and/or hyperphosphata......In bone scan patients with dialysis-treated chronic kidney disease (CKD) and hyperparathyroidism, soft tissue accumulation of technetium-99 m hydroxy/methylene diphosphonate (Tc-99 m-HDP/MDP) has been reported primarily in case reports and usually explained by hypercalcaemia and...... patients diagnosed with secondary hyperparathyroidism admitted for Tc-99 m-HDP bone scan. Baseline characteristics and mean concentrations of biochemical markers (including P-calcium and P-phosphate) taken 0-3 months prior to the bone scans were collected. Soft tissue uptake was detected on bone scans....../or hyperphosphataemia. As human vascular smooth muscle cells produce hydroxyapatite during cell culture with increased phosphate levels and as Tc-99 m-HDP/MDP primarily binds to hydroxyapatite, we hypothesized that soft tissue accumulation would be found in patients with hyperphosphataemia. We identified 63 CKD...

  18. X-ray electron investigation of technetium compounds

    International Nuclear Information System (INIS)

    Gerasimov, V.N.; Kryuchkov, S.V.; Kuzina, A.F.; Kulakov, V.M.; Pirozhkov, S.V.; Spitsyn, V.I.; Gosudarstvennyj Komitet po Ispol'zovaniyu Atomnoj Ehnergii SSSR, Moscow. Inst. Atomnoj Ehnergii)

    1982-01-01

    Investigation results of a number of technetium compounds using the method of X-ray electron spectroscopy have been presented for the first time. Calculation of effective charge for compounds without Tc-Tc bond and cluster complexes with strong Tc-Tc bond is made. Strong interdependence of effective charge and properties of technetium clusters is shown. Binding energies for certain cluster complexes of technetium with halides are given

  19. Environmental behavior of technetium-99

    International Nuclear Information System (INIS)

    Turcotte, M.D.S.

    1982-12-01

    This report presents a review of the literature on technetium-99. The chemical and physical properties of some technetium compounds are considered, and a discussion of possible source terms is included. Literature on the environmental behavior of technetium is presented, including its behavior in the bodies of animals and humans. The primary sources of Tc-99 in the environment are fallout from atomic detonations and releases from nuclear fuel reprocessing plants. The environmental behavior of technetium-99 has been studied predominantly with respect to movement in soil and accumulation in plants. There is a surprising scarcity of data on behavior of Tc-99 in the atmosphere and in aquatic systems. Additional work needs to be conducted in these two areas to determine behavior and to acquire baseline concentration data. Much of the soil work has produced contradictory results. In-depth studies of holdup mechanisms for Tc-99 in both geological repositories and soil need to be conducted. Since plants represent a potential bioaccumulation of Tc-99, plant uptake studies of Tc-99 under field conditions also need to be done

  20. Technetium-99m scintigraphy associated with spondylolysis of the lumbar spine in children

    International Nuclear Information System (INIS)

    Kubota, Wataru; Sudo, Nariomi; Nakazima, Kiyonori; Nakamura, Mitsutaka

    1987-01-01

    Eight children with spondylolysis, aged from 10 to 18 years of age, underwent bone scanning with technetium-99m methylene diphosphonic acid. Radioisotope (RI) uptake was significantly observed in the site marked by the separation of the pars interarticularis, compared with the other sites between the articular processes. This showed the increase in metabolic activity of bones, providing supplementary information in the initial diagnosis. At the completion of conservative treatment, RI uptake decreased, being seemingly attributable to the improvement of subjective symptoms. Bone scanning may, however, be unhelpful in detecting synostosis. (Namekawa, K.)

  1. Technetium-99m scintigraphy associated with spondylolysis of the lumbar spine in children

    Energy Technology Data Exchange (ETDEWEB)

    Kubota, W.; Sudo, N.; Nakazima, K.; Nakamura, M.

    1987-02-01

    Eight children with spondylolysis, aged from 10 to 18 years of age, underwent bone scanning with technetium-99m methylene diphosphonic acid. Radioisotope (RI) uptake was significantly observed in the site marked by the separation of the pars interarticularis, compared with the other sites between the articular processes. This showed the increase in metabolic activity of bones, providing supplementary information in the initial diagnosis. At the completion of conservative treatment, RI uptake decreased, being seemingly attributable to the improvement of subjective symptoms. Bone scanning may, however, be unhelpful in detecting synostosis.

  2. Technetium behaviour under deep geological conditions

    International Nuclear Information System (INIS)

    Kumata, M.; Vandergraaf, T.T.

    1993-01-01

    The migration behaviour of technetium under deep geological conditions was investigated by performing column tests using groundwater and altered granitic rock sampled from a fracture zone in a granitic pluton at a depth of about 250 m. The experiment was performed under a pressure of about 0.7 MPa in a controlled atmosphere glove box at the 240 m level of the Underground Research Laboratory (URL) near Pinawa, Manitoba, Canada. The technetium was strongly sorbed on the dark mafic minerals in the column. With the exception of a very small unretarded fraction that was eluted with the tritiated water, no further breakthrough of technetium was observed. This strong sorption of technetium on the mineral surface was caused by reduction of Tc(VII), probably to Tc(IV) even though the groundwater was only mildly reducing. (author) 5 figs., 4 tabs., 15 refs

  3. Periarticular uptake of /sup 99m/technetium diphosphonate in psoriatics. Correlation with cutaneous activity

    International Nuclear Information System (INIS)

    Namey, T.C.; Rosenthall, L.

    1976-01-01

    The periarticular uptake of /sup 99m/technetium-labeled diphosphonate (/sup 99m/TcDP) was compared in 12 patients hospitalized for psoriasis and in 12 hospitalized for other dermatoses not associated with arthropathy. The 12 patients with psoriasis had recent onset disease of less than 5 years duration; neither group had historical or clinical evidence of arthritis. All psoriatics had markedly abnormal scans with symmetrically increased periarticular uptake about the imaged joints. None of the controls had similar findings. In 4 patients scanned with /sup 99m/technetium-pertechnetate within 24 hours of their /sup 99m/TcDP scan, no evidence of inflammatory synovitis was found. Three of these patients were serially imaged with /sup 99m/TcDP at intervals of 2 weeks to 3 months after their initial study, when obvious clinical improvement in their psoriasis was apparent. Improvement in the radionuclide joint images was demonstrated in some of the patients, but none reverted to normal during the study period. In light of recent evidence for the preferential binding of /sup 99m/TcDP to immature collagen, it is suggested that psoriasis may represent a generalized, but uncharacterized, collagen disorder present in bone as well as skin, linking the cutaneous disease with the potential for arthropathy

  4. Technetium migration in natural clays

    International Nuclear Information System (INIS)

    Luebke, Maria

    2015-01-01

    The present work was performed within the joint research project ''Retention of repository relevant radionuclides in argillaceous rocks and saline systems'' (contract no.: 02E10981), funded by the Federal Ministry for Economic Affairs and Energy (BMWi). The aim was to obtain first insights into the interaction of the long-lived fission product technetium and natural clay with regard to a repository for high-level nuclear waste. For this purpose Opalinus Clay from Mont Terri (northern Switzerland) was used as a reference material. The nuclide technetium-99 will contribute to the radiotoxicity of spent nuclear fuel for more than thousand years due to its long half-live. In case of a leakage of the storage vessels, the geochemistry of technetium is determined by its oxidation state, at which only the oxidation states +IV and +VII are relevant. Because of the high solubility and low affinity to sorption on surfaces of minerals, Tc(VII) is considered to be very mobile and thus the most hazardous species. The focuses of this study therefore are diffusion experiments with this mobile species and investigations of the effect of ferrous iron on the mobility and speciation of technetium.rnThe interaction of technetium and Opalinus Clay was studied in sorption and diffusion experiments varying several parameters (pH value, addition of reducing agents, effect of oxygen, diffusion pathways). In the course of this study spatially resolved investigations of the speciation have been performed on Opalinus Clay thin sections and bore cores for the first time. In addition to the speciation, further information regarding elemental distributions and crystalline phases near technetium enrichments were obtained. Supplementary investigations of powder samples allowed determining the molecular structure of technetium on the clay surface.rnBoth the combination of sorption experiments with spectroscopic investigations and the diffusion experiment exhibit a reduction of Tc

  5. Extraosseous uptake of sup(99m)technetium methylene diphosphonate: Neuroblastoma or radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Sty, J R; Kun, L; Casper, J; Babbitt, D P [Wisconsin Univ., Milwaukee (USA). Dept. of Radiology

    1980-01-01

    A child with a ganglioneuroblastoma and tumor uptake of sup(99m)technetium methylene diphosphonate (sup(99m)Tc-MDP) is presented. After surgical removal of an encapsulated tumor and radiation therapy, an interval bone scan demonstrated the same presurgical abnormality. Awareness of abnormal uptake of sup(99m)Tc-MDP in irradiated renal tissue prevents interpreting radiation nephritis as recurrent tumor.

  6. Does aspiration of bones and joints affect results of later bone scanning

    International Nuclear Information System (INIS)

    Canale, S.T.; Harkness, R.M.; Thomas, P.A.; Massie, J.D.

    1985-01-01

    To determine the effect, if any, of needle aspiration on /sup 99m/Tc bone scanning, three different areas of 15 dogs were first aspirated and then imaged with technetium bone scintigraphy. The hip joint was aspirated, the distal femoral metaphysis was drilled and aspirated, and the tibial periosteum was scraped with an 18- or 20-gauge needle. Varying amounts of trauma were inflicted to simulate varying difficulties at aspiration. /sup 99m/Tc bone scans were obtained from 5 h to 10 days later. There was no evidence of focal technetium uptake after any hip joint aspiration. This was consistent regardless of the amount of trauma inflicted or the time from aspiration to bone scanning. Metaphyseal cortical drilling and tibial periosteal scraping occasionally caused some focal uptake when scanning was delayed greater than 2 days. When osteomyelitis or pyarthrosis is clinically suspected, joint aspiration can be performed without fear of producing a false- positive bone scan

  7. Determination of pyrophosphate and sulfate using polyhexamethylene guanidine hydrochloride-stabilized silver nanoparticles.

    Science.gov (United States)

    Terenteva, E A; Apyari, V V; Dmitrienko, S G; Garshev, A V; Volkov, P A; Zolotov, Yu A

    2018-04-01

    Positively charged polyhexamethylene guanidine hydrochloride-stabilized silver nanoparticles (PHMG-AgNPs) were prepared and applied as a colorimetric probe for single-step determination of pyrophosphate and sulfate. The approach is based on the nanoparticles aggregation leading to change in their absorption spectra and color of the solution. Due to both electrostatic and steric stabilization these nanoparticles show decreased sensitivity relatively to many common anions, which allows for simple and rapid direct single-step determination of pyrophosphate and sulfate. Effects of different factors (time of interaction, pH, concentrations of anions and the nanoparticles) on aggregation of PHMG-AgNPs and analytical performance of the procedure were investigated. The method allows for the determination of pyrophosphate and sulfate in the range of 0.16-2μgmL -1 and 20-80μgmL -1 with RSD of 2-5%, respectively. The analysis can be performed using either spectrophotometry or naked-eye detection. Practical application of the method was shown by the example of pyrophosphate determination in baking powder sample. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Positioning irrigation of contrast cystography for diagnosis of occult vesicoureteric reflux: association with technetium-99m dimercaptosuccinic acid scans.

    Science.gov (United States)

    Berger, Christoph; Becker, Tanja; Koen, Mark; Zeino, Mazen; Fitz, Friedrich; Beheshti, Mohsen; Wolf-Kohlmeier, Iris; Haim, Silke; Riccabona, Marcus

    2013-12-01

    Positioning irrigation of contrast (PIC) cystography identifies occult or PIC vesicoureteral reflux (PIC-VUR) in children with recurrent febrile urinary tract infections (UTI) but no vesicoureteric reflux (VUR) on standard voiding cystourethrogram (VCUG). We sought to identify the relationship between PIC-VUR and renal scarring in technetium-99m dimercaptosuccinic acid (DMSA) scans. We retrospectively analysed PIC cystograms and DMSA scans for 154 kidneys in 81 children (65 girls; 16 boys; median age, 4.7 years; range, 0.9-15.2). Renal scarring was graded on a scale of 0-3. DMSA scans were pathologic in 66 patients (81%). Children had experienced mean 3.8 febrile UTI (range 1-25). Forty-seven (58%) children had a history of reflux, including 15 (19%) with previous anti-reflux operations. Indications for PIC cystography were recurrence of febrile UTI after either bilateral negative VCUG (66 children) or unilateral VUR (15 children) with contralateral/bilateral scarring or reflux that had changed sides in subsequent VCUGs. PIC-VUR was bilateral in 63, unilateral in 12, and absent in 6 children. Statistically significant associations between PIC-VUR grade and severity of renal scarring were identified in inter-individual (n = 77, p = 0.017) and intra-individual (refluxing vs. nonrefluxing kidney; n = 12, p = 0.008) analyses. After excluding patients with history of VUR, statistical significance was maintained in inter-individual analysis (n = 49; p = 0.018). The data suggest an association between PIC-VUR and severity of renal scarring, and legitimise the use of PIC cystography in children with renal scarring due to recurrent febrile UTI but negative findings on VCUG. Copyright © 2012 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  9. Technetium discharges into the environment

    International Nuclear Information System (INIS)

    Luykx, F.

    1986-01-01

    Technetium-99 is the most important technetium isotope released to the environment because of its long life and its relatively high fission yield. Its release to date, mainly as a result of nuclear fuel reprocessing, is estimated to be of the order of 1000 TBq. The quantity from nuclear weapons testing would only be some 10-15% of this value. (author)

  10. A pyrophosphate-responsive gadolinium(III) MRI contrast agent.

    Science.gov (United States)

    Surman, Andrew J; Bonnet, Célia S; Lowe, Mark P; Kenny, Gavin D; Bell, Jimmy D; Tóth, Eva; Vilar, Ramon

    2011-01-03

    This study shows that the relaxivity and optical properties of functionalised lanthanide-DTPA-bis-amide complexes (lanthanide=Gd(3+) and Eu(3+) , DTPA=diethylene triamine pentaacetic acid) can be successfully modulated by addition of specific anions, without direct Ln(3+) /anion coordination. Zinc(II)-dipicolylamine moieties, which are known to bind strongly to phosphates, were introduced in the amide "arms" of these ligands, and the interaction of the resulting Gd-Zn(2) complexes with a range of anions was screened by using indicator displacement assays (IDAs). Considerable selectivity for polyphosphorylated species (such as pyrophosphate and adenosine-5'-triphosphate (ATP)) over a range of other anions (including monophosphorylated anions) was apparent. In addition, we show that pyrophosphate modulates the relaxivity of the gadolinium(III) complex, this modulation being sufficiently large to be observed in imaging experiments. To establish the binding mode of the pyrophosphate and gain insight into the origin of the relaxometric modulation, a series of studies including UV/Vis and emission spectroscopy, luminescence lifetime measurements in H(2) O and D(2) O, (17) O and (31) P NMR spectroscopy and nuclear magnetic resonance dispersion (NMRD) studies were carried out. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. The regulation of technetium-99 discharges at Sellafield

    International Nuclear Information System (INIS)

    Mayall, A.

    2002-01-01

    The reprocessing of spent Magnox fuel at BNFL Sellafield produces a liquid waste concentrate containing technetium-99 and other, more radiotoxic, radionuclides such as plutonium and americium. The concentrate is known as medium active concentrate (MAC). Prior to 1981, MAC was discharged to sea untreated after several years' storage, during which short-lived radionuclides underwent radioactive decay. In the early 1980s, discharges of MAC were suspended and it was retained in storage tanks, pending the construction of a plant to remove the radionuclides of greatest radiological concern (these did not include technetium- 99). The Enhanced Actinide Removal Plant started operation in 1994 and began to clear the backlog of stored waste MAC, as well as current arisings from Magnox reprocessing. As a consequence technetium-99 was once more discharged to sea. Subsequently, concentrations of this radionuclide in the marine environment increased. In particular, there was a significant increase in the concentration of technetium-99 in lobster in the Irish Sea. An increase in technetium-99 has also been detected at locations far distant from Sellafield, e.g. in Scandinavian coastal waters, albeit at very low concentrations. This dispersal of technetium- 99 throughout the Irish Sea and further afield has therefore caused concern, although the radiological impact is low. This paper examines the nature and source of the technetium-99 in sea discharges at Sellafield and the levels of past and current discharges as well as their impact. It goes on to describe the Environment Agency's recent proposals on the future regulation of technetium-99 discharges and how these should lead to substantial reductions in not only technetium-99 discharges, but also of other radionuclides such as caesium-137 and strontium-90. (author)

  12. About 250 cases of skeletal scintiscanning using sup(99m)Tc-labelled stannous pyrophosphate. Analytical and critical study

    International Nuclear Information System (INIS)

    Suss, Leopold.

    1975-01-01

    The physical and biological characteristics of 85 Sr, 87 Sr, 18 F and sup(99m)Tc, four radionuclides suitable for skeletal imaging are reviewed. Their mechanism of localization, advantages and disadvantages are described. The physical characteristics and relative tissue concentration of sup(99m)Tc compare favorably to those of the other bone-seeking radionuclides. 250 cases of various skeletal diseases are presented, using sup(99m)Tc-pyrophosphate as a skeletal imaging agent. This radiopharmaceutical proves to be useful particularly in the detection of bone metastases. Bone scans, however, are not 100% positive with metastatic diseases and false negative do occasionally occur. The scan is also helpful in demonstrating the extent of metastatic bone disease [fr

  13. Chemistry of technetium in the environment

    International Nuclear Information System (INIS)

    McFadden, K.M.

    1980-08-01

    Technetium release to the environment may occur during separation and recovery of spent nuclear fuels, or in disposal of aqueous waste from nuclear facilities, hospitals, or other users. The chemistry and sources of technetium are reviewed as a basis for prediction of its behavior in the environment

  14. Substitution reactions of technetium complexes

    International Nuclear Information System (INIS)

    Omori, T.

    1997-01-01

    Substitution reactions of a series of technetium complexes are considered in comparison with corresponding reactions of rhenium. Rhenium and technetium complexes are rather inert in substitution reactions, the latter are characterized by greater rate constants when they proceed according to dissociative mechanism. In rare cases when k Tc /k Re id little it is assumed that the reaction proceeds according to the associative mechanism. (author)

  15. Extraosseous uptake of sup(99m)technetium methylene diphosphonate: Neuroblastoma or radiation therapy

    International Nuclear Information System (INIS)

    Sty, J.R.; Kun, L.; Casper, J.; Babbitt, D.P.

    1980-01-01

    A child with a ganglioneuroblastoma and tumor uptake of sup(99m)technetium methylene diphosphonate (sup(99m)Tc-MDP) is presented. After surgical removal of an encapsulated tumor and radiation therapy, an interval bone scan demonstrated the same presurgical abnormality. Awareness of abnormal uptake of sup(99m)Tc-MDP in irradiated renal tissue prevents interpreting radiation nephritis as recurrent tumor. (orig.) [de

  16. Final Report, Research Program to Investigate the Fundamental Chemistry of Technetium

    International Nuclear Information System (INIS)

    Lukens, Wayne W. Jr.; Fickes, Michael J.; Bucher, Jerome J.; Burns, Carol J.; Edelstein, Norman M.; Shuh, David K.

    2000-01-01

    The purpose is to increase the basic scientific understanding of technetium chemistry to better understand the behavior of technetium in chemical environments relevant to DOE. Two important areas in need of study are the behavior of technetium in highly alkaline solutions similar to high-level nuclear waste, and its behavior in different waste forms. This research program addressed these two needs. Two separate approaches were used in this program. The first focus was to understand the basic solution chemistry of technetium, which underlies its behavior in the highly alkaline environment of the nuclear waste tanks located at the Savannah River and Hanford Sites. The specific problems at these sites are related to the anomalous oxidation state of technetium (Schroeder 1995). Although, at high pH, technetium should exist in its highest oxidation state as TcO 4 - , soluble, lower-valent technetium species have been observed in certain wastes. The specific unknowns that this program sought to answer are the nature of lower valent technetium species that can be formed in highly alkaline solution and whether pertechnetate undergoes radiolytic reduction in highly alkaline solution when nitrate is present in excess. The second focus area is the behavior of technetium immobilized in various waste forms. The behavior of technetium in cement wastes was examined to gain information about its long-term stability. Specifically, this research examined the oxidation of reduced technetium species by components present in high-level waste that are incorporated into cement waste along with technetium

  17. Biosynthesis of monoterpenes. Enantioselectivity in the enzymatic cyclization of (+)- and (-)-linalyl pyrophosphate to (+)- and (-)-pinene and (+)- and (-)-camphene

    International Nuclear Information System (INIS)

    Croteau, R.; Satterwhite, D.M.; Cane, D.E.; Chang, C.C.

    1988-01-01

    Cyclase I from Salvia officinalis leaf catalyzes the conversion of geranyl pyrophosphate to the stereo-chemically related bicyclic monoterpenes (+)-alpha-pinene and (+)-camphene and to lesser quantities of monocyclic and acyclic olefins, whereas cyclase II from this plant tissue converts the same acyclic precursor to (-)-alpha-pinene, (-)-beta-pinene and (-)-camphene as well as to lesser amounts of monocyclics and acyclics. These antipodal cyclizations are considered to proceed by the initial isomerization of the substrate to the respective bound tertiary allylic intermediates (-)-(3R)- and (+)-(3S)-linalyl pyrophosphate. [(3R)-8,9-14C,(3RS)-1E-3H]Linalyl pyrophosphate (3H:14C = 5.14) was tested as a substrate with both cyclases to determine the configuration of the cyclizing intermediate. This substrate with cyclase I yielded alpha-pinene and camphene with 3H:14C ratios of 3.1 and 4.2, respectively, indicating preferential, but not exclusive, utilization of the (3R)-enantiomer. With cyclase II, the doubly labeled substrate gave bicyclic olefins with 3H:14C ratios of from 13 to 20, indicating preferential, but not exclusive, utilization of the (3S)-enantiomer in this case. (3R)- and (3S)-[1Z-3H]linalyl pyrophosphate were separately compared to the achiral precursors [1-3H]geranyl pyrophosphate and [1-3H]neryl pyrophosphate (cis-isomer) as substrates for the cyclizations. With cyclase I, geranyl, neryl, and (3R)-linalyl pyrophosphate gave rise exclusively to (+)-alpha-pinene and (+)-camphene, whereas (3S)-linayl pyrophosphate produced, at relatively low rates, the (-)-isomers. With cyclase II, geranyl, neryl, and (3S)-linalyl pyrophosphate yielded exclusively the (-)-isomer series, whereas (3R)-linalyl pyrophosphate afforded the (+)-isomers at low rates

  18. The performance of gel technetium-99m generator

    International Nuclear Information System (INIS)

    Liu Yishu

    2004-01-01

    Technetium-99m, as one of the important radionuclides in nuclear medical science, has been widely used for diseases diagnosis in both developed and developing countries for many years. Technetium-99m can be obtained from both fission-type and gel-type Tc-99m generator. Fission-type generator was prepared by Molybdenum-99 separated from fission products of uranium-235 and gel-type was prepared by irradiating nature MoO 3 in reactor, and a series of chemical and physical processes. This paper briefly describes the manufacturing technical process of gel-type Technetium-99 generator, including the preparation of target containing nature MoO 3 , the target irradiation in reactor, gel preparation, gel filtration and drying, dried gel cracking, generator loading and activity calibration of generator. The performances of gel-type Technetium-99m generator, such as elution efficiency, elution profile, the pH, Mo breakthrough, Zirconium content, radiochemical purity, radionuclidic purity, sterility and pyrogencity of eluate, are also expatiated in detail. Comparing with fission-type Technetium-99m generator, the defects of gel-type Technetium-99m generator are enumerated and their overcoming solutions are recommended in this paper. (author)

  19. Research program to investigate the fundamental chemistry of technetium

    Energy Technology Data Exchange (ETDEWEB)

    McKeown, David A.; Buechele, Andrew C.; Lukens, Wayne W.; Muller, Isabelle S.; Shuh, David K.; Pegg, Ian L.

    2007-10-12

    The objective of this research is to increase the knowledge of the fundamental technetium chemistry necessary to address challenges to the safe, long-term disposal of high-level nuclear waste posed by this element. The primary issues examined during the course of this project were the behavior of technetium and its surrogate rhenium during waste vitrification and glass corrosion. Since the redox behavior of technetium can play a large role in determining its volatility, one goal of this research was to better understand the behavior of technetium in glass as a function of the redox potential of the glass melt. In addition, the behavior of rhenium was examined, since rhenium is commonly used as a surrogate for technetium in waste vitrification studies. A number of glasses similar to Hanford Low Activity Waste (LAW) glasses were prepared under controlled atmospheres. The redox state of the glass was determined from the Fe(II)/Fe(III) ratio in the cooled glass, and the speciation of technetium and rhenium was determined by x-ray absorption fine structure (XAFS) spectroscopy. The behavior of rhenium and technetium during glass alteration was also examined using the vapor hydration test (VHT).

  20. Sources and behavior of technetium in the environment

    International Nuclear Information System (INIS)

    Schulte, E.H.; Scoppa, P.

    1987-01-01

    Technetium is a man-made element produced in increasing amounts during the last decades. The chemical and physical properties of some technetium compounds are considered, and a discussion of possible source terms is included. Literature on the environmental behavior of technetium is reviewed to evaluate its transfer and equilibrium distribution in aquatic and terrestrial ecosystems. Considerable effort has been expended in the last years in order to understand the biogeochemical processes responsible for the long-term behavior of technetium in the environment and its transfer through food chains as well as to identify critical pathways of the long-lived radioisotope Tc-99 from the environment to man. (Auth.)

  1. The labeling of kanamycin using radionuclide of technetium as an agent for early detection of infectious deseases

    International Nuclear Information System (INIS)

    Widyasari, E.; Zainuddin, M.N.; Nuraeni, W.

    2013-01-01

    Infectious diseases are still the leading cause of death in the world. Early detection and determination of the exact location of infection and accurate imaging through the use of nuclear techniques can facilitate treatment. Antibiotics radioactive labeled compound otherwise be able to be a solution to distinguish between infective and non-infective inflammatory. Kanamycin is an antibiotic used for the treatment of infections where other drugs such as penicillin and several other drugs that are less potent infection can not be used. This study aims to determine the optimum labeling conditions of 99m Tc-kanamycin in order to obtain high labeling efficiency. Kanamycin has successfully labeled with technetium-99m through indirect labeling method using pyrophosphate as a co-ligand. Labeling efficiency and determination of radiochemical purity of these compounds simultaneously determined by ascending paper chromatography using Whatman paper 3 as the stationary phase, and acetone as the mobile phase to separate the radiochemical impurities in the form of 99m Tc-pertechnetate; while impurities in the form of reduced 99m Tc-separated by using the stationary phase ITLC-SG and 0.5 N NaOH as mobile phase. The result showed that the optimal labeling conditions was obtained on the use of 6 mg kanamycin, 300 mg SnCl2, 1.5 mg of Na-pyrophosphate, and pH = 6. The incubation time of 0-30 min at room temperature, provide labeling efficiency of 96.54 ± 0.36%. The successful of kanamycin labeling with high efficiency makes 99m Tc-kanamycin potentially to be used as a radiopharmaceutical for the early detection of infectious diseases. (author)

  2. Improving the diagnosis of acute appendicitis in children with atypical clinical findings using the technetium-99m hexamethylpropylene amine oxime-labelled white-blood-cell abdomen scan

    International Nuclear Information System (INIS)

    Yan Dahchin; Shiau Yuchien; Wang Jhijoung; Ho Shungtai; Kao Chiahung

    2002-01-01

    Heading AbstractBackground. Diagnosing acute appendicitis in children with equivocal signs and symptoms may be difficult. The usual approach is hospital observation and frequent re-examination. However, many surgeons are reluctant to delay surgery because of the risk of perforation and a negative laparotomy.Objective. To assess and compare the value of the technetium-99m hexamethylpropylene amine oxime ( 99m Tc-HMPAO)-labelled white-blood-cell (WBC) abdomen scan in the diagnosis of acute appendicitis in children with atypical clinical presentation.Patients and methods. Fifty children with acute right lower quadrant abdominal pain and possible acute appendicitis, but atypical findings were included. After IV injection of 99m Tc-HMPAO-labelled WBCs, serial anterior abdomen scans were obtained using a gamma camera.Results. Thirty-three children underwent surgery, while 17 children were managed conservatively and were followed up for at least 1 month. Four children had false-positive results and one child had a false-negative scan result. The overall sensitivity, specificity, accuracy, positive predictive value and negative predictive value of the scan to diagnose acute appendicitis in children with atypical findings was 96.7, 80.0, 90.0, 87.8 and 94.1%, respectively.Conclusions. The 99m Tc-HMPAO WBC abdomen scan is a potential tool for diagnosing acute appendicitis in children with atypical clinical findings. The high sensitivity and negative predictive value allows early discharge from the emergency department to avoid costly observation in hospital and potentially unnecessary surgery in those patients with negative scans. (orig.)

  3. Final Report, Research Program to Investigate the Fundamental Chemistry of Technetium

    Energy Technology Data Exchange (ETDEWEB)

    Lukens Jr., Wayne W.; Fickes, Michael J.; Bucher, Jerome J.; Burns, Carol J.; Edelstein, Norman M.; Shuh, David K.

    2000-12-23

    The purpose is to increase the basic scientific understanding of technetium chemistry to better understand the behavior of technetium in chemical environments relevant to DOE. Two important areas in need of study are the behavior of technetium in highly alkaline solutions similar to high-level nuclear waste, and its behavior in different waste forms. This research program addressed these two needs. Two separate approaches were used in this program. The first focus was to understand the basic solution chemistry of technetium, which underlies its behavior in the highly alkaline environment of the nuclear waste tanks located at the Savannah River and Hanford Sites. The specific problems at these sites are related to the anomalous oxidation state of technetium (Schroeder 1995). Although, at high pH, technetium should exist in its highest oxidation state as TcO{sub 4}{sup {minus}}, soluble, lower-valent technetium species have been observed in certain wastes. The specific unknowns that this program sought to answer are the nature of lower valent technetium species that can be formed in highly alkaline solution and whether pertechnetate undergoes radiolytic reduction in highly alkaline solution when nitrate is present in excess. The second focus area is the behavior of technetium immobilized in various waste forms. The behavior of technetium in cement wastes was examined to gain information about its long-term stability. Specifically, this research examined the oxidation of reduced technetium species by components present in high-level waste that are incorporated into cement waste along with technetium.

  4. Corrosion and antifouling characteristics of technetium 99 in seawater

    International Nuclear Information System (INIS)

    Spitsyn, V.I.; Strekalov, P.V.; Balakhovskij, O.A.; Mikhajlovskij, Yu.N.

    1982-01-01

    The results are presented of studying the corrosive and antifouling properties of metallic technetium-99 in the Barents Sea and the Sea of Japan. Foil of 99 Tc glued on acrylic plastic served as a sample. High corrosion resistance and antifouling properties exhibited by 99 Tc in seawater point to favorable prospects of further studies aimed at development of new methods for protection against corrosion and fouling of metallic structures and parts with the use of technetium. The antifouling properties of technetium would evidently be used most efficiently when coating materials of high corrosion resistance to seawater (titanium, stainless steels, special alloys, etc.) with layers of technetium. The use of technetium for coating low-alloyed or carbon steels employed in seawater is yet problematic

  5. Research Program to Investigate the Fundamental Chemistry of Technetium

    International Nuclear Information System (INIS)

    Edelstein, Norman M.; Burns, Carol J.; Shuh, David D.; Lukens, Wayne

    2000-01-01

    Technetium (99Tc, half-life = 2.13x105 years, b-emitter) is one of the radionuclides of major concern for nuclear waste disposal. This concern is due to the long half-life of 99Tc, the ease with which pertechnetate, TcO4 -, migrates in the geosphere, and the corresponding regulatory considerations. The problem of mobility of pertechnetate in the environment is compounded by the fact that pertechnetate is the thermodynamically stable form of technetium in aerobic environments. These two factors present challenges for the safe, long term immobilization of technetium in waste forms. Because of the stability of pertechnetate, technetium has been assumed to exist as pertechnetate in the aqueous phase of nuclear waste tanks. However, recent studies indicate that a significant fraction of the technetium is in a different chemical form. This program addresses the fundamental solution chemistry of technetium in the waste tank environment, and in a second part, the stability of technetium in various waste forms. The chemistry of this element will be studied in aqueous solutions at high pH, with various added salts such as nitrate, nitrite, and organic complexants, and as a function of radiation dose, to determine whether radiolysis effects can reduce TcO4 -. A separate facet of this research is the search for chemical forms of technetium that may be thermodynamically and/or kinetically stable and may be incorporated in various waste forms for long term storage. This phase of the program will address the problem of the possible oxidation of lower valent technetium species in various waste form matrices and the subsequent leaching of the highly soluble TcO4 -

  6. The Role of Thiamine Pyrophosphate in Prevention of Cisplatin Ototoxicity in an Animal Model

    Directory of Open Access Journals (Sweden)

    Ozan Kuduban

    2013-01-01

    Full Text Available Objective. The aim of this study was to evaluate the effectiveness of thiamine pyrophosphate against cisplatin-induced ototoxicity in guinea pigs. Materials and Methods. Healthy guinea pigs (n=18 were randomly divided into three groups. Group 1 (n=6 received an intraperitoneal injection of saline solution and cisplatin for 7 days, group 2 (n=6 received an intraperitoneal injection of thiamine pyrophosphate and cisplatin for 7 days, and group 3 (n=6 received only intraperitoneal injection of saline for 7 days. The animals in all groups were sacrificed under anesthesia, and their cochleas were harvested for morphological and biochemical observations. Results. In group 1, receiving only cisplatin, cochlear glutathione concentrations, superoxide dismutase, and glutathione peroxidase activities significantly decreased (P<0.05 and malondialdehyde concentrations significantly increased (P<0.05 compared to the control group. In group 2, receiving thiamine pyrophosphate and cisplatin, the concentrations of enzymes were near those of the control group. Microscopic examination showed that outer hair cells, spiral ganglion cells, and stria vascularis were preserved in group 2. Conclusion. Systemic administration of thiamine pyrophosphate yielded statistically significant protection to the cochlea of guinea pigs from cisplatin toxicity. Further experimental animal studies are essential to determine the appropriate indications of thiamine pyrophosphate before clinical use.

  7. Diagnosis of acute cholecystitis using hepatobiliary scan with technetium-99m PIPIDA

    International Nuclear Information System (INIS)

    Bennett, M.T.; Sheldon, M.I.; dos Remedios, L.V.; Weber, P.M.

    1981-01-01

    Sixty patients were evaluated for acute abdominal pain using technetium-99m PIPIDA hepatobiliary imaging. The sensitivity of the test was 90.6 percent in all patients and the accuracy was 93.3 percent. In the evaluation of acutely ill patients with right upper quadrant pain, fever, nausea and vomiting, hepatobiliary imaging with PIPIDA is the preferred test for diagnosing acute cholecystitis. If the test is positive, disease of the gallbladder and probably acute cholecystitis are present. Early operation can proceed if desirable. If the test is negative and the bilirubin level is less than 5.0 mg/dl, acute cholecystitis is not present. In such cases conservative treatment is appropriate, and follow-up tests should be performed to evaluate the possibility of chronic cholecystitis. When the bilirubin level exceeds 5.0 mg/dl, the test is often indeterminate

  8. Extraosseous uptake of /sup 99/sup(m)technetium methylene diphosphonate. Neuroblastoma or radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Sty, J R; Kun, L; Casper, J; Babbitt, D P

    1980-01-01

    A child with a ganglioneuroblastoma and tumor uptake of /sup 99/sup(m)technetium methylene diphosphate (/sup 99/sup(m)Tc-MDP) is presented. After surgical removal of an encapsulated tumor and radiation therapy, an interval bone scan demonstrated the same presurgical abnormality. Awareness of abnormal uptake of /sup 99/sup(m)Tc-MDP in irradiated renal tissue prevents interpreting radiation nephritis as recurrent tumor.

  9. Technetium-aspirin molecule complexes

    International Nuclear Information System (INIS)

    El-Shahawy, A.S.; Mahfouz, R.M.; Aly, A.A.M.; El-Zohry, M.

    1993-01-01

    Technetium-aspirin and technetium-aspirin-like molecule complexes were prepared. The structure of N-acetylanthranilic acid (NAA) has been decided through CNDO calculations. The ionization potential and electron affinity of the NAA molecule as well as the charge densities were calculated. The electronic absorption spectra of Tc(V)-Asp and Tc(V)-ATS complexes have two characteristic absorption bands at 450 and 600 nm, but the Tc(V)-NAA spectrum has one characteristic band at 450 nm. As a comparative study, Mo-ATS complex was prepared and its electronic absorption spectrum is comparable with the Tc-ATS complex spectrum. (author)

  10. Measurement and behaviour of technetium in fast reactor fuel reprocessing

    International Nuclear Information System (INIS)

    Ferguson, C.; Kyffin, T.W.

    1986-02-01

    A method is described for the spectrophotometric measurement of technetium in plant solutions from the reprocessing of fast reactor fuel. The technetium is selectively extracted using tri-iso-octylamine. After back extraction, thiocyanate is added, in the presence of tetrabutyl-ammonium hydroxide, to form the red hexa-thiocyanato anionic complex in a chloroform medium. The concentration of the technetium is then calculated from the spectrophotometric measurement of this complex. This method was applied to bulk samples, collected during a PFR fuel reprocessing campaign, to identify the main routes followed by technetium through the reprocessing plant. In order to understand the probable behaviour of technetium in the process plant streams, an investigation into the influence of plutonium IV nitrate on the extraction of Tc (VII) into 20%v/v tributyl phosphate/odourless kerosene solution from nitric acid solutions, was initiated. The results of this investigation, along with the known distribution coefficient for the extraction of the uranyl/technetium complex U0 2 (N0 3 )(Tc0 4 ).2TBP and the redox chemistry of technetium, are used to predict the probable behaviour of technetium in the process plant streams. This predicted behaviour is compared with the experimental results and reasonable agreement is obtained between experiment and theory, considering the history of the samples analysed. (author)

  11. Study of the synthesis of ammonia over technetium catalysts

    International Nuclear Information System (INIS)

    Spetsyn, V.I.; Mikhailenko, I.E.; Pokrovskaya, O.V.

    1982-01-01

    The catalytic properties of technetium in the synthesis of ammonia have been studied in the present work. Technetium catalysts according to specific yield surpass all know catalysts for the synthesis of ammonia. The enhanced catalytic activity of technetium compared to manganese and rhenium is apparently explained by the presence of the radioactivity of 99 Tc. The processes of adsorption, orientation of the adsorbed molecules, and their binding energies can differ during radiation action. Irradiation of the carrier, occurring through #betta#-emission of 99 Tc, with doses of 4-8 x 10 3 rad/day, increased the number of defects in the crystal structure where stabilization of technetium atoms was possible. The existence of charged centers can cause an increase in the dissociative chemisorption of nitrogen, which is the limiting stage of the process. Technetium catalysts possess a stable catalytic activity and do not require its restoration for several months. Results suggest that the use of technetium as a catalyst for the synthesis of ammonia has real advantages and potential possibilities

  12. Emission tomography with sup(99m)Tc-pyrophosphate in the diagnosis of acute myocardial infarction

    International Nuclear Information System (INIS)

    Poeyhoenen, L.; Uusitalo, A.; Virjo, A.

    1985-01-01

    Electrocardiograms (ECG) and enzyme criteria are usually used to confirm the diagnosis of acute myocardial infarction in the case of chest pain. However, ECG is not always diagnostic. Elevated enzyme values may be due to causes other than myocardial infarction. In uncertain cases, the ECG and enzyme criteria can be supplemented by emission tomography, performed with technetium pyrophosphate that will accumulate in the site of infarction. Twenty-nine patients with suspected acute myocardial infarction were studied with emission tomography. Of these 12 had acute transmural infarction. Both enzyme tests and ECG were diagnostic in only 7 of these 12 cases, 4 had positive enzyme tests but a nondiagnostic ECG and in one case neither enzymes nor ECG were diagnostic. In 11 patients the infarcted myocardial area was detected with emission tomography. Six patients had acute nontransmural infarction. Only 2 of these had positive emission tomography. The chest pain was not due to infarction in 11 patients. All these patients had negative emission tomography. The sensitivity of emission tomography was 92% and specificity 100% in transmural acute infarction. In nontransmural infarction the specificity was only 33%. Emission tomography is a valuable diagnostic tool. It may be the decisive method when ECG and enzymes are not diagnostic. Emissin tomography also shows the localization and size of the infarcted area in the myocardium. (orig.)

  13. Study of the chemical behaviour of technetium during irradiated fuels reprocessing

    International Nuclear Information System (INIS)

    Zelverte, A.

    1988-04-01

    This paper deals with the preparation of the lower oxidation states +III +IV and +V of technetium in nitric acid and its behaviour during the reprocessing of nuclear fuels (PUREX process). The first part of this work is a bibliographical study of this element in solution without any strong ligand. By chemical and electrochemical technics, pentavalent, tetravalent and trivalent technetium species, were prepared in nitric acid. The following chemical reactions are studied: - trivalent and tetravalent technetium oxidation by nitrate ion. - hydrazine and tetravalent uranium oxidation catalysed by technetium: in those reactions, we point out unequivocally the prominent part of trivalent and tetravalent technetium, - technetium behaviour towards hydroxylamine. Technetium should not cause any disturbance in the steps where hydroxylamine is employed to destroy nitrous acid and hydrazine replacement by hydroxylamine in uranium-plutonium partition could contribute to a best reprocessing of nuclear fuels [fr

  14. Voltammetric assay of extremely low technetium concentrations following enrichment at the HMDE after reaction with Thiocyanate

    International Nuclear Information System (INIS)

    Friedrich, M.; Ruf, H.

    1984-12-01

    It is known that in sulfuric acid solution pertechnetate is reduced by thiocyanate to form thiocyanate complexes. After this reaction the technetium acquires the capability of being adsorbed at the hanging mercury drop electrode (HMDE) provided that a potential of -0,40 V (vs. Ag/AgCl) has been applied to the electrode. If, by application of the differential pulse voltammetry after the phase of deposition the potential at the electrode is scanned cathodically, traces of technetium can be determined very sensitively by evaluation of the peak current recorded at minus 1,27 V (Ag/AgCl). The effect is still being enhanced by the presence of not interfering small perrhenate amounts. The reproducibility of the measured values is excellent. (orig.) [de

  15. Determination of stability constants of pyrophosphate complexes. 2. Influence of divalent cations: the magnesium

    International Nuclear Information System (INIS)

    Courriere, P.; Guillemart, A.; Besnard, J.-C.

    1978-01-01

    The stability constants of the complexes of pyrophosphate with magnesium have been determined directly from the titration curves of sodium pyrophosphate in presence of Mg 2+ with hydrochloric acid by a least-square iterative method at the temperature of 25 0 C and at a ionic strength adjusted to unity [fr

  16. The chemical speciation of technetium in the environment: a literature survey

    International Nuclear Information System (INIS)

    Sparkes, S.T.; Long, S.E.

    1987-07-01

    This report reviews the current understanding of the chemical forms and behaviour of technetium in the environment. Technetium (VII) is the dominant species in most systems, however when reducing conditions arise technetium (IV) species predominate. Pertechnetate is a highly mobile ion in aqueous media and can exhibit significant environmental transfer. Technetium (IV) is readily sorbed by sediments and is able to complex with various ligands which subsequently determine its fate. Complexation with high molecular weight organic moieties reduces the availability of technetium although this is not necessarily the case with smaller molecules. In plants, technetium is absorbed as TcO 4 - and can become incorporated into organic molecules. The technetium present in such forms is generally considered less available for uptake by the ingesting animal than aqueous TcO 4 - , although significant transfer of this element has been reported from food into eggs. Areas of potential future interest are suggested. (author)

  17. Supplemental Report: Application of Emission Spectroscopy to Monitoring Technetium

    International Nuclear Information System (INIS)

    Spencer, W.A.

    2000-01-01

    This report provides supplemental information to an earlier report BNF-98-003-0199, ''Evaluation of Emission Spectroscopy for the On-Line Analysis of Technetium''. In this report data is included from real Hanford samples as well as for solutions spiked with technetium. This supplemental work confirms the ability of ICP-ES to monitor technetium as it breaks through an ion exchange process

  18. Synthesis and characterization of volatile technetium compound

    International Nuclear Information System (INIS)

    Childs, Bradley C.; Poineau, Frederic; Czerwinski, Ken R.

    2013-01-01

    Technetium-99 is an important fission (T 1/2 = 2.13.105 y) product of the nuclear industry. Technetium in its highest oxidation state (VII) is highly mobile and can represent a threat to the environment. There are over 55 million gallons of high level mixed waste located at the Hanford site. Waste tanks at the Hanford site contain Tc that could potentially leak, and in the context of management of technetium, a glass waste form was proposed to counteract the issue. In the process of synthesizing melt glass between the temperatures of 600°C and 1100°C, volatile technetium compounds were observed in the reaction tube. These compounds displayed characteristic colors based upon the reaction environments of either breathing air or nitrogen gas. A breathing air atmosphere produces a red compound that adheres to the walls of the reaction tube. An atmosphere of nitrogen gas produces a white compound that was observed on the walls of the reaction tube. (author)

  19. Concentration of technetium by marine organisms

    International Nuclear Information System (INIS)

    Koyanagi, T.; Suzuki, Y.; Nakamura, R.; Nakahara, M.

    1990-01-01

    Accumulation and excretion of technetium by marine organisms were observed in radioisotope tracer experiments to determine concentration factors for estimating radiation dose to humans from radioactive pollution of marine environments. Marine fish, crustaceans, mollusks, echinoderms, and seaweeds were reared in sea water labeled with 95m Tc to observe uptake from sea water. The organisms were then transferred into unlabeled sea water for depuration experiments. Concentration factors were calculated from uptake and excretion rates. Also considered was the contribution of food-chain transfer of technetium, observed by administering labeled seaweeds to mollusks or echinoderms. Low accumulations were shown by fish, crustaceans, pelecypods and cephalopods, whereas high concentration factors were observed in gastropods and seaweeds. Species specificity or specific accumulation in special organs or tissues was not evident except in seaweed, where the difference was clearly species-associated. Relatively high rates of technetium retention were observed in the organisms administered labeled seaweed. The higher concentrations observed in gastropods, compared to those in pelecypods, were thought to result from different feed habits. The adaptability of some species as indicator organisms for monitoring 99 Tc in sea water was recognized, but the contribution of technetium to radiation dose was considered insignificant

  20. Transfer of technetium from soil to paddy and upland rice

    International Nuclear Information System (INIS)

    Yanagisawa, Kei; Muramatsu, Yasuyuki

    1995-01-01

    Soil-plant transfer factors (concentration ratio between the plant and soil) of technetium in paddy and upland rice plants were obtained from laboratory experiments. The transfer factor is one of the most important parameters for environmental radiation dose assessment. Technetium tracer ( 95m TcO 4 - ) was added to the soil prior to rice cultivation. The transfer factor of technetium for the hulled grains (brown rice) of paddy rice (≤0.0002) was much lower than for that of upland rice (0.021). The transfer factors for both types of hulled grains were much lower than in the leaves. The technetium decontamination rate from hulled grains by polishing was 34%, the percentage of the weight decrease being 12%. The concentration of technetium in the soil solution collected from the paddy rice soil (flooded conditions) decreased rapidly with time due to its adsorption on the soil. In the upland rice soil (non-flooded) solution, the decrease in the technetium concentration was fairly slow. The low transfer factors for the paddy rice plants could be explained by the immobilization of technetium in the flooded soil. The oxidation-reduction potentials (Eh) in the flooded soil decreased rapidly with time. We conclude that technetium tracer added as TcO 4 - to flooded soil is readily transformed to an insoluble form (e.g.TcO 2 ) under the reducing conditions provided by flooding. (author)

  1. Factors affecting the stability and biodistribution of {sup 99m} Tc labelled Sn-pyrophosphate freeze dried kits in normal mice.

    Energy Technology Data Exchange (ETDEWEB)

    Elkolaly, M T; Elwatery, A S; Elghany, E A [Radioisotope production and labelled compounds department, hot lab. center, Atomic Energy Authority, Cairo, (Egypt)

    1995-10-01

    The present study has shown that about 5% of Sn (II) in {sup 99m} Tc labelled Sn-pyrophosphate (Sn-PYP) freeze dried kit was oxidized during kit formulation. Also, {gamma}-irradiation doses of 25 and 50 KGy led to Sn (II) losses of about 9.8 and 27.7%, respectively. In-vitro stability and radiochemical purity were biologically confirmed in mice and a high quality scan was achieved on waiting for 3 hours after injection. 3 figs., 6 tabs.

  2. Process for producing radioactive technetium 99 m

    International Nuclear Information System (INIS)

    Karageozian, H.L.

    1979-01-01

    Active aluminium oxide containing Molybdenum 99 and technetium 99 m is treated with a neutral solvent consisting of water, methylethylketone and ethanol. Technetium 99 m remains on the chromatographic material after drying, in the form of a dry powder. Other aliphatic alcohols can also be utilised. (DG) [de

  3. Studying thermal dehydration of double nickel alkali metal pyrophosphates

    International Nuclear Information System (INIS)

    Bykanova, T.A.; Lavrov, A.V.; AN SSSR, Moscow. Inst. Obshchej i Neorganicheskoj Khimii)

    1978-01-01

    The methods of thermogravimetry, paper chromatography, infrared spectroscopy and X-ray phase analysis were used in studying the process of thermal dehydration of pyrophosphates of the M 2 Ni 3 (P 2 O 7 ) 2 xnH 2 O type (where n=6, 10; M=Na, K, Rb, Cs, NH 4 ). The dehydration of Cs 2 Ni 3 (P 2 O 7 ) 2 x10H 2 O proceeds in a single stage (endothermal effect at 210 deg C). The exothermal effects at 730 and 690 deg C correspond to the crystallization of the amorphous dehydration products. It has been established that binary pyrophosphates of nickel with alkali metals decompose when heated into Ni 3 (PO 4 ) 2 +MPO 4

  4. Linkable thiocarbamoylbenzamidines as ligands for bioconjugation of Rhenium and Technetium; Kopplungsfaehige Thiocarbamoylbenzamidine als Liganden zur Biokonjugation von Rhenium und Technetium

    Energy Technology Data Exchange (ETDEWEB)

    Castillo Gomez, Juan Daniel

    2015-04-27

    Bioconjugation reactions with Rhenium and Technetium are of high importance for the development of novel radiopharmaceuticals for nuclear medicine. In this thesis the possibilities for bioconjugation using linkable Thiocarmbamoylbenzamidines as ligands for the complexation of Rhenium and Technetium were examined.

  5. Research program to investigate the fundamental chemistry of technetium

    International Nuclear Information System (INIS)

    Shuh, David K.; Lukens, Wayne W.; Burns, Carol J.

    2003-01-01

    The objective of this research is to increase the knowledge of the fundamental technetium chemistry that is necessary to address challenges to the safe, long-term remediation of high-level waste posed by this element. These challenges may be divided into two categories: unexpected behavior of technetium in high-level waste tanks at the Hanford and Savannah River Sites and the behavior of technetium in waste forms

  6. Research program to investigate the fundamental chemistry of technetium

    Energy Technology Data Exchange (ETDEWEB)

    Shuh, David K.; Lukens, Wayne W.; Burns, Carol J.

    2003-12-19

    The objective of this research is to increase the knowledge of the fundamental technetium chemistry that is necessary to address challenges to the safe, long-term remediation of high-level waste posed by this element. These challenges may be divided into two categories: unexpected behavior of technetium in high-level waste tanks at the Hanford and Savannah River Sites and the behavior of technetium in waste forms.

  7. Bone scan in diagnosis of infectious osteoarthritis

    International Nuclear Information System (INIS)

    Marandian, M.H.; Mortazavi, H.; Behvad, A.; Haghigat, H.; Lessani, M.; Youssefian, B.

    1979-01-01

    Bone scan with Technetium 99m is harmless method of evaluation of skeletal lesions. It is safe in pediatrics age group and it can be used in early diagnosis of infectious osteoarthritis. Bone scan differentiate osteomyelitis from cellulitis, and also it may help in diagnosis of subclinical involvement of rheumatoid arthritis, benign and malignant bone tumors, stress fractures and periostitis. We report results of bone scan in 30 pediatrics patients as follow: osteomyelitis 9 cases, cellulitis 4 cases, infectious arthritis 7 cases, tuberculous osteoarthritis 2 cases, rheumatoid arthritis 2 cases, and other different diseases 9 cases [fr

  8. A method for the determination of technetium in environmental waters

    International Nuclear Information System (INIS)

    Robb, P.; Warwick, P.; Malcolme-Lawes, D.J.

    1985-01-01

    A method is described which can be used to determine technetium-99 levels in a range of water types. Ruthenium isotopes which may interfere in the analysis are removed from the sample by precipitation before concentration of pertechnetate onto an ion-exchange column. Other nuclides can be removed from the column using NaOH before elution of the technetium using NaSCN. The technetium in the NaSNC eluent can then be extracted into butan-2-one which can be evaporated onto a planchette. Technetium-99m is used as a yield tracer and after this has decayed away to negligible levels. The amount of technetium on the planchette can be determined by measuring the rate of beta radiation emission from the final concentrate. (author)

  9. Lung scan abnormalities in asthma and their correlation with lung function

    International Nuclear Information System (INIS)

    Vernon, P.; Burton, G.H.; Seed, W.A.; Charing Cross Hospital, London

    1986-01-01

    We have used asthma as a model of airways disease to test how well an automated, quantitative method of analysis of lung scans correlates with physiological measurements of disturbed lung function and gas exchange. We studies 25 asthmatics (age 16-73) of widely differing severity (forced expiratory volume in 1-s FEV 1 22%-123% of predicted value), who had airways tests, arterial blood gas analysis, and krypton-technetium lung scans within a short time of each other. In all patients with airways obstruction and in some with normal function during remission, scans showed the typical appearances of multiple defects of ventilation and perfusion. The severity of ventilation defects was assessed from the posterior view of the krypton scan compared to an age- and sex-matched normal range to yield an underventilation score. This correlated closely with the severity of airways obstruction as measured by forced expiratory manouevres. Ventilation and perfusion defects were usually imperfectly matched; the severity of this was computed using a subtraction method applied to the counts on the posterior krypton and technetium scans. The degree of mismatch was inversely related to the arterial partial pressure of oxygen (r=-0.86). The results suggest that computer scan analysis can provide usual functional information about the lung in airways disease. (orig.)

  10. Positive thyroid cancer scintigraphy using technetium-99m methoxyisobutylisonitrile

    International Nuclear Information System (INIS)

    Nemec, J.; Nyvltova, O.; Blazek, T.; Vlcek, P.; Racek, P.; Novak, Z.; Preiningerova, M.; Hubackova, M.; Krizova, M.; Zimak, J.; Bilek, R.

    1996-01-01

    The aim of the study was to evaluate the possibility of detecting thyroid cancer recurrences without the need for withdrawal of thyroid suppressive treatment. Upper-body or whole-body scintigraphy was performed in a group of 200 patients evaluated for differentiated thyroid cancers in 1993 and 1994 using technetium-99m sestamibi. Scans were performed 20-30 min following i.v. administration of 500 MBq of 99m Tc-methoxyisobutylisonitrile (MIBI). Bone and lung metastases were detected with very high sensitivity and specificity, with a very high predictive value of negative results and a somewhat lower predictive value of positive results. The sensitivity and specificity of findings in the neck were lower but the predictive value of negative results was high. Whole-body scans with 99m Tc-MIBI are a useful tool in the follow-up of patients with differentiated thyroid cancer, for the detection of distant metastatic lesions. (orig.)

  11. Kinetics of sup(99m)Tc-pyrophosphate in comparison with 85Sr in acutely and chronically altered soft part and bone regions

    International Nuclear Information System (INIS)

    Buell, U.; Balser, D.; Boehner-Schoberth, I.; Frey, K.W.; Muenchen Univ.; Muenchen Univ.

    1974-01-01

    Summarizing our findings, we can state that *Tc-pyrophosphate concentrates in acutely inflammated soft tissue and some malignant soft-tissue tumors. In comparison with *Sr, Tc-pyrophosphate concentration is relatively higher but absolute concentration does not exceed the Sr concentration up to 3 hours post injection. 24 hours after injection we found a significantly higher *Tc-PyP concentration in all soft tissues, whether inflammated or not, pure muscle excluded. These findings correlate well with the collagen contents in the tissues, which is underlined by the fact that the highest *Tc-PyP concentration in normal soft tissue examined has been found in the patellar tendon. In rheumatic arthritis the positive joint scan with *Tc-PyP could be due to the damaged soft tissue only, even when bone destruction is evident. In humans bearing osteoarthritis of the hip joint we found a threefold higher concentration of *Tc-PyP in the joint capsule compared with the muscle. 85 Sr concentration was twice as high. (orig.) [de

  12. Control of technetium at the Portsmouth Gaseous Diffusion Plant

    International Nuclear Information System (INIS)

    Saraceno, A.J.

    1981-01-01

    Technetium-99 entered the gaseous diffusion complex as a volatile impurity in recycled uranium that was fed to the Paducah Gaseous Diffusion Plant. Subsequently, it entered the Oak Ridge and Portsmouth cascades as an impurity in Paducah product feed. Most of the technetium was adsorbed on cascade equipment in increasingly high concentrations as it moved up the cascade. Since the low energy beta radiation produced by technetium cannot penetrate cascade equipment, it presents no significant hazard to workers as long as it remains inside of equipment. However, when equipment that contains high concentrations of technetium is opened for maintenance or change-out, precautions are taken to ensure worker safety. Traps containing activated alumina are used at the plant vent streams to limit radioactive emissions as far as possible. Annual vent stream emissions have been well below DOE limits. To allow continued compliance, other potential trapping agents have been tested. Several that limit emissions more effectively than activated alumina have been found. Other traps containing magnesium fluoride are used in the upper cascade to reduce the technetium concentration. Waste solutions from decontamination can also contain technetium. These solutions must either be stored for controlled discharge or treated to remove the technetium. To allow the latter, an ion exchange facility is being installed for operation by the end of FY-1982. Liquid discharges at Portsmouth have usually been less than 5% of the DOE imposed limits

  13. Some aspects of the assay of technetium in environmental waters

    International Nuclear Information System (INIS)

    Robb, P.

    1983-09-01

    Technetium, as 99 Tc, was rapidly concentrated from large sample volumes (> 500 cm 3 ) by use of an anion exchange column after removal of ruthenium isotopes by precipitation. The bulk of the technetium can be removed from the resin by elution with sodium thiocyanate followed by further concentration by extraction with butan-2-one. Evaporation of solvent onto a planchette followed by measurement of emitted beta radiation can determine technetium levels. Method is capable of removing between 10 -15 and 10 -6 g of technetium from 500 cm 3 of water. (author)

  14. Scintigraphic investigation of sacroiliac disease

    International Nuclear Information System (INIS)

    Lentle, B.C.; Russell, A.S.; Percy, J.S.; Jackson, F.I.

    1977-01-01

    Bone scintigraphs obtained with both technetium-99m polyphosphate and technetium-99m pyrophosphate have been abnormal at the sacroiliac joints of 44 patients with definite ankylosing spondylitis (AS). Because of the normal registration of the sacroiliac joints on bone scintigraphy, it has been necessary to develop a profile-scan technique to quantify the abnormality that proves to be significantly different from the normal finding. In 17 patients with a strong clinical suspicion of AS but normal radiographs, the sacroiliac joints have frequently been abnormal. This finding is meaningful because there is a common occurrence in this group of the histocompatibility antigen HL A-B27, known to be a marker of AS. We also note the frequency of abnormal sacroiliac scintigrams in 26 patients with rheumatoid arthritis and in a group of other diseases--Crohn's disease, uveitis, psoriasis, ulcerative colitis, and Reiters' disease--all of which share some of the manifestations of AS

  15. The scintigraphic investigation of sacroiliac disease.

    Science.gov (United States)

    Lentle, B C; Russell, A S; Percy, J S; Jackson, F I

    1977-06-01

    Bone scintigraphs obtained with both Technetium-99m polyphosphate and Technetium-99m pyrophosphate have been abnormal at the sacroiliac joints of 44 patients with definite ankylosing spondylitis (AS). Because of the normal registration of the sacroiliac joints on bone scintigraphy, it has been necessary to develop a profile-scan technique to quantify the abnormality that proves to be significantly different from the normal finding. In 17 patients with a strong clinical suspicion of AS but normal radiographs, the sacroiliac joints have frequently been abnormal. This finding is meaningful because there is a common occurence in this group of the histocompatibility antigen HL A-B27, known to be a marker of AS. We also note the frequency of abnormal sacroiliac scinitigrams in 26 patients with rheumatoid arthritis and in a group of other diseases-Crohn's disease, uveitis, psoriasis, ulcerative colitis, and Reiter's disease-all of which share some of the manifestations of AS.

  16. Sensor Function for Butyrophilin 3A1 in Prenyl Pyrophosphate Stimulation of Human Vγ2Vδ2 T Cells

    Science.gov (United States)

    Wang, Hong; Morita, Craig T.

    2016-01-01

    Vγ2Vδ2 T cells play important roles in human immunity to pathogens and in cancer immunotherapy by responding to isoprenoid metabolites, such as (E)-4-hydroxy-3-methyl-but-2-enyl pyrophosphate and isopentenyl pyrophosphate. The Ig superfamily protein butyrophilin (BTN)3A1 was shown to be required for prenyl pyrophosphate stimulation. We proposed that the intracellular B30.2 domain of BTN3A1 binds prenyl pyrophosphates, resulting in a change in the extracellular BTN3A1 dimer that is detected by Vγ2Vδ2 TCRs. Such B30.2 binding was demonstrated recently. However, other investigators reported that the extracellular BTN3A1 IgV domain binds prenyl pyrophosphates, leading to the proposal that the Vγ2Vδ2 TCR recognizes the complex. To distinguish between these mechanisms, we mutagenized residues in the two binding sites and tested the mutant BTN3A1 proteins for their ability to mediate prenyl pyrophosphate stimulation of Vγ2Vδ2 T cells to proliferate and secrete TNF-α. Mutagenesis of residues in the IgV site had no effect on Vγ2Vδ2 T cell proliferation or secretion of TNF-α. In contrast, mutagenesis of residues within the basic pocket and surrounding V regions of the B30.2 domain abrogated prenyl pyrophosphate-induced proliferation. Mutations of residues making hydrogen bonds to the pyrophosphate moiety also abrogated TNF-α secretion, as did mutation of aromatic residues making contact with the alkenyl chain. Some mutations further from the B30.2 binding site also diminished stimulation, suggesting that the B30.2 domain may interact with a second protein. These findings support intracellular sensing of prenyl pyrophosphates by BTN3A1 rather than extracellular presentation. PMID:26475929

  17. Fluorido complexes of technetium

    International Nuclear Information System (INIS)

    Mariappan Balasekaran, Samundeeswari

    2013-01-01

    Fluorine chemistry has received considerable interest during recent years due to its significant role in the life sciences, especially for drug development. Despite the great nuclear medicinal importance of the radioactive metal technetium in radiopharmaceuticals, its coordination chemistry with the fluorido ligand is by far less explored than that of other ligands. Up to now, only a few technetium fluorides are known. This thesis contains the synthesis, spectroscopic and structural characterization of novel technetium fluorides in the oxidation states ''+1'', ''+2'', ''+4'' and ''+6''. In the oxidation state ''+6'', the fluoridotechnetates were synthesized either from nitridotechnetic(VI) acid or from pertechnetate by using reducing agent and have been isolated as cesium or tetraethylammonium salts. The compounds were characterized spectroscopically and structurally. In the intermediate oxidation state ''+4'', hexafluoridotechnetate(IV) was known for long time and studied spectroscopically. This thesis reports novel and improved syntheses and solved the critical issues of early publications such as the color, some spectroscopic properties and the structure of this key compound. Single crystal analyses of alkali metal, ammonium and tetramethylammonium salts of hexafluoridotechnetate(IV) are presented. In aqueous alkaline solutions, the ammonium salt of hexafluoridotechnetate(IV) undergoes hydrolysis and forms an oxido-bridged dimeric complex. It is the first step hydrolysis product of hexafluoridotechnetate(IV) and was characterized by spectroscopic and crystallographic methods. Low-valent technetium fluorides with the metal in the oxidation states of ''+2'' or ''+1'' are almost unknown. A detailed description of the synthesis and characterization of pentafluoridonitrosyltechnetate(II) is presented. The complex was isolated as alkali metal salts, and spectroscopic as well as structural features of the complexes are presented. Different salts of the trans

  18. Acute myocardial infarction with a non-diagnostic electrocardiogram. Case presentation and overview

    Energy Technology Data Exchange (ETDEWEB)

    Przybojewski, J Z; Gilburt, S G.M. [Tygerberg Hospital, Stellenbosch (South Africa). Dept. of Internal Medicine

    1983-12-17

    The clinical presentation of a young hypertensive White man with acute high lateral non-transmural myocardial infarction (MI) is documented. This diagnosis was established on the grounds of a history of chest pain, elevated serial serum enzyme levels, technetium-99m pyrophosphate ('hot-spot') scintigraphy, exercise thallium-201 ('cold-spot') scanning, left ventricular cine angiography and selective coronary arteriography. Daily resting 12-lead ECGs failed to demonstrate unequivocal features of acute non-transmural subendocardial MI. The diagnostic difficulties facing the clinician in a case of acute MI associated with a non-diagnostic ECG are stressed, and the ECG features of acute subendocardial MI are reviewed.

  19. Sodium pyrophosphate enhances iron bioavailability from bouillon cubes fortified with ferric pyrophosphate.

    Science.gov (United States)

    Cercamondi, Colin I; Duchateau, Guus S M J E; Harika, Rajwinder K; van den Berg, Robin; Murray, Peter; Koppenol, Wieneke P; Zeder, Christophe; Zimmermann, Michael B; Moretti, Diego

    2016-08-01

    Fe fortification of centrally manufactured and frequently consumed condiments such as bouillon cubes could help prevent Fe deficiency in developing countries. However, Fe compounds that do not cause sensory changes in the fortified product, such as ferric pyrophosphate (FePP), exhibit low absorption in humans. Tetra sodium pyrophosphate (NaPP) can form soluble complexes with Fe, which could increase Fe bioavailability. Therefore, the aim of this study was to investigate Fe bioavailability from bouillon cubes fortified with either FePP only, FePP+NaPP, ferrous sulphate (FeSO4) only, or FeSO4+NaPP. We first conducted in vitro studies using a protocol of simulated digestion to assess the dialysable and ionic Fe, and the cellular ferritin response in a Caco-2 cell model. Second, Fe absorption from bouillon prepared from intrinsically labelled cubes (2·5 mg stable Fe isotopes/cube) was assessed in twenty-four Fe-deficient women, by measuring Fe incorporation into erythrocytes 2 weeks after consumption. Fe bioavailability in humans increased by 46 % (P<0·005) when comparing bouillons fortified with FePP only (4·4 %) and bouillons fortified with FePP+NaPP (6·4 %). Fe absorption from bouillons fortified with FeSO4 only and with FeSO4+NaPP was 33·8 and 27·8 %, respectively (NS). The outcome from the human study is in agreement with the dialysable Fe from the in vitro experiments. Our findings suggest that the addition of NaPP could be a promising strategy to increase Fe absorption from FePP-fortified bouillon cubes, and if confirmed by further research, for other fortified foods with complex food matrices as well.

  20. TESTING GUIDELINES FOR TECHNETIUM-99 ADSORPTION ON ACTIVATED CARBON

    International Nuclear Information System (INIS)

    Byrnes, M.E.

    2010-01-01

    CH2M HILL Plateau Remediation Company (CHPRC) is currently evaluating the potential use of activated carbon adsorption for removing technetium-99 from groundwater as a treatment method for the Hanford Site's 200 West Area groundwater pump-and-treat system. The current pump-and-treat system design will include an ion-exchange (IX) system for selective removal of technetium-99 from selected wells prior to subsequent treatment of the water in the central treatment system. The IX resin selected for technetium-99 removal is Purolite A530E. The resin service life is estimated to be approximately 66.85 days at the design technetium-99 loading rate, and the spent resin must be replaced because it cannot be regenerated. The resulting operating costs associated with resin replacement every 66.85 days are estimated at $0.98 million/year. Activated carbon pre-treatment is being evaluated as a potential cost-saving measure to offset the high operating costs associated with frequent IX resin replacement. This document is preceded by the Literature Survey of Technetium-99 Groundwater Pre-Treatment Option Using Granular Activated Carbon (SGW-43928), which identified and evaluated prior research related to technetium-99 adsorption on activated carbon. The survey also evaluated potential operating considerations for this treatment approach for the 200 West Area. The preliminary conclusions of the literature survey are as follows: (1) Activated carbon can be used to selectively remove technetium-99 from contaminated groundwater. (2) Technetium-99 adsorption onto activated carbon is expected to vary significantly based on carbon types and operating conditions. For the treatment approach to be viable at the Hanford Site, activated carbon must be capable of achieving a designated minimum technetium-99 uptake. (3) Certain radionuclides known to be present in 200 West Area groundwater are also likely to adsorb onto activated carbon. (4) Organic solvent contaminants of concern (COCs) will

  1. TESTING GUIDELINES FOR TECHNETIUM-99 ABSORPTION ON ACTIVATED CARBON

    Energy Technology Data Exchange (ETDEWEB)

    BYRNES ME

    2010-09-08

    CH2M HILL Plateau Remediation Company (CHPRC) is currently evaluating the potential use of activated carbon adsorption for removing technetium-99 from groundwater as a treatment method for the Hanford Site's 200 West Area groundwater pump-and-treat system. The current pump-and-treat system design will include an ion-exchange (IX) system for selective removal of technetium-99 from selected wells prior to subsequent treatment of the water in the central treatment system. The IX resin selected for technetium-99 removal is Purolite A530E. The resin service life is estimated to be approximately 66.85 days at the design technetium-99 loading rate, and the spent resin must be replaced because it cannot be regenerated. The resulting operating costs associated with resin replacement every 66.85 days are estimated at $0.98 million/year. Activated carbon pre-treatment is being evaluated as a potential cost-saving measure to offset the high operating costs associated with frequent IX resin replacement. This document is preceded by the Literature Survey of Technetium-99 Groundwater Pre-Treatment Option Using Granular Activated Carbon (SGW-43928), which identified and evaluated prior research related to technetium-99 adsorption on activated carbon. The survey also evaluated potential operating considerations for this treatment approach for the 200 West Area. The preliminary conclusions of the literature survey are as follows: (1) Activated carbon can be used to selectively remove technetium-99 from contaminated groundwater. (2) Technetium-99 adsorption onto activated carbon is expected to vary significantly based on carbon types and operating conditions. For the treatment approach to be viable at the Hanford Site, activated carbon must be capable of achieving a designated minimum technetium-99 uptake. (3) Certain radionuclides known to be present in 200 West Area groundwater are also likely to adsorb onto activated carbon. (4) Organic solvent contaminants of concern (COCs

  2. Value of bone scintigraphy in the search for metastases of primary bronchial carcinomas (relative to 8 observation)

    International Nuclear Information System (INIS)

    Lanuit, Robert.

    1976-01-01

    99m-technetium-labelled pyrophosphates are used at present. This technique combines the tropism of inorganic phosphates for the skeleton with the particularly suitable physical characteristics of technetium. The bone receives on irradiation of 0.5 rads for 10 millicuries of technetium, i.e. the equivalent of three lung X-rays, which means that the examination can safety be carried out on children. The scintigraph is performed with a two-head scanner giving a frontal image, showing in particular the shoulders, sternum, ribs and pelvic belt, and a dorsal image giving a better view of the spine and especially the sacro-iliac joints. When bone metastases are investigated by scintigraphic as compared to radiographic examination it should be remembered that 99mTc-labelled pyrophosphate scintigraphy, while revealing bone metastases at a pre-radiological stage in some cases, cannot distinguish between a benign and a malignant hyperfixing lesion nor show whether or not several lesions on the same scintigram are similar in origin. In this respect these two paraclinical examinations are complementary and give excellent results when used together [fr

  3. Ion exchange removal of technetium from salt solutions

    International Nuclear Information System (INIS)

    Walker, D.D.

    1983-01-01

    Ion exchange methods for removing technetium from waste salt solutions have been investigated by the Savannah River Laboratory (SRL). These experiments have shown: Commercially available anion exchange resins show high selectivity and capacity for technetium. In column runs, 150 column volumes of salt solution were passed through an ion exchange column before 50% 99 Tc breakthrough was reached. The technetium can be eluted from the resin with nitric acid. Reducing resins (containing borohydride) work well in simple hydroxide solutions, but not in simulated salt solutions. A mercarbide resin showed a very high selectivity for Tc, but did not work well in column operation

  4. The radiopharmaceuticals labelled with technetium-99m and the radiopharmacy; Les radiopharmaceutiques marques au technetium-99m et la radiopharmacie

    Energy Technology Data Exchange (ETDEWEB)

    Bodenant, V

    1998-10-01

    In less than fifty years, the place of nuclear medicine is become primordial. Among all the radiopharmaceuticals used in nuclear medicine, the technetium-99m is the most used because of its physico-chemical properties and its great availability with the molybdenum-99m - technetium-99m generator. Since 1992, the radiopharmaceuticals, the packages, the generators are included in the pharmaceutic monopole. They are now under the reliability of the radio-pharmacist. This thesis has for object to introduce these different radiopharmaceuticals labelled with technetium-99m and to show the primordial place of the radio-pharmacist in a service of nuclear medicine. (N.C.)

  5. Uptake and distribution of technetium in several marine algae

    International Nuclear Information System (INIS)

    Bonotto, S.; Gerber, G.B.; Garten, C.T. Jr.; Vandecasteele, C.M.; Myttenaere, C.; Van Baelen, J.; Cogneau, M.; van der Ben, D.

    1983-01-01

    The uptake or chemical form of technetium in different marine algae (Acetabularia, Cystoseira, Fucus) has been examined and a simple model to explain the uptake of technetium in the unicellular alga, Acetabularia, has been conceptualized. At low concentrations in the external medium, Acetabularia can rapidly concentrate technetium. Concentration factors in excess of 400 can be attained after a time of about 3 weeks. At higher mass concentrations in the medium, uptake of technetium by Acetabularia becomes saturated resulting in a decreased concentration factor (approximately 10 after 4 weeks). Approximately 69% of the total radioactivity present in /sup 95m/Tc labelled Acetabularia is found in the cell cytosol. In Fucus vesiculosus, labelled with /sup 95m/Tc, a high percentage of technetium is present in soluble ionic forms while approximately 40% is bound, in this brown alga, in proteins and polysaccharides associated with cell walls. In the algal cytosol of Fucus vesiculosus, about 45% of the /sup 95m/Tc appears to be present as anionic TcO - 4 and the remainder is bound to small molecules. 8 references, 5 figures, 1 table

  6. The molybdenum-technetium solar neutrino experiment

    International Nuclear Information System (INIS)

    Schroeder, N.C.; Wolfsberg, K.; Rokop, D.J.

    1991-01-01

    The authors are attempting to measure the time-averaged 8 B solar-neutrino flux over 10 Myr by measuring 98 Tc produced through the 98 Mo( nu ,e - ) reaction in a deeply buried molybdenum deposit. This will test the prediction of periodic mixing of the Sun's core over long time intervals. To separate technetium from 10,000-ton quantities of Henderson ore, the authors have taken advantage of the commercial processing of molybdenite. Technetium, volatilized during roasting of molybdenite to MoO 3 , was scrubbed from the gas stream and collected on anion exchange columns. After sample reduction and chemical separation and purification they measured technetium, as TcO 4 - , using negative thermal ionization mass spectrometry. Measurement of 99 Tc in spiked and 98 Tc in unspiked fractions from one sample gives an apparent solar neutrino production rate of 95.8 SNU. However, roaster memory probably invalidates this result

  7. Biosynthesis of monoterpenes. Stereochemistry of the enzymatic cyclizations of geranyl pyrophosphate to (+)-alpha-pinene and (-)-beta-pinene

    International Nuclear Information System (INIS)

    Croteau, R.; Satterwhite, D.M.; Wheeler, C.J.; Felton, N.M.

    1989-01-01

    The conversion of geranyl pyrophosphate to (+)-alpha-pinene and to (-)-beta-pinene is considered to proceed by the initial isomerization of the substrate to (-)-(3R)- and to (+)-(3S)-linalyl pyrophosphate, respectively, and the subsequent cyclization of the anti, endo-conformer of these bound intermediates by mirror-image sequences which should result in the net retention of configuration at C1 of the geranyl precursor. Incubation of (1R)-[2-14C,1-3H]- and (1S)-[2-14C,1-3H]geranyl pyrophosphate with (+)-pinene cyclase and with (-)-pinene cyclase from common sage (Salvia officinalis) gave labeled (+)-alpha- and (-)-beta-pinene of unchanged 3H/14C ratio in all cases, and the (+)- and (-)-olefins were stereoselectively converted to (+)- and (-)-borneol, respectively, which were oxidized to the corresponding (+)- and (-)-isomers of camphor, again without change in isotope ratio. The location of the tritium was determined in each case by stereoselective, base-catalyzed exchange of the exo-alpha-hydrogens of these derived ketones. The results indicated that the configuration at C1 of the substrate was retained in the enzymatic transformations to the (+)- and (-)-pinenes, which is entirely consistent with the syn-isomerization of geranyl pyrophosphate to linalyl pyrophosphate, transoid to cisoid rotation, and anti, endo-cyclization of the latter. The absolute stereochemical elements of the antipodal reaction sequences were confirmed by the selective enzymatic conversions of (3R)- and (3S)-1Z-[1-3H]linalyl pyrophosphate to (+)-alpha-pinene and (-)-beta-pinene, respectively, and by the location of the tritium in the derived camphors as before. The summation of the results fully defines the overall stereochemistry of the coupled isomerization and cyclization of geranyl pyrophosphate to the antipodal pinenes

  8. Studies on the mechanism of pyrophosphate-mediated uptake of iron from transferrin by isolated rat-liver mitochondria

    International Nuclear Information System (INIS)

    Konopka, K.; Romslo, I.; Bergen Univ.

    1981-01-01

    1. Respiring rat liver mitochondria accumulate iron released from transferrin by pyrophosphate. The amount of iron accumulated is 1-1.5 nmol mg protein -1 h -1 , or approximately 60% of the amount of iron mobilized from transferrin. 2. The uptake declines if respiration is inhibited, substrate is depleted, or the experiments are run under anaerobic conditions. Substrate, depletion and respiratory inhibitors are less inhibitory under anaerobic conditions. 3. More than 80% of the amount of iron accumulated by aerobic, actively respiring mitochondria can be chelated by bathophenanthroline sulphonate, and with deuteroporphyrin included, up to 30% of the amount of iron accumulated is recovered as deuteroheme. Iron accumulated by respiration-inhibited mitochondria under aerobic conditions is not available for heme synthesis. 4. With time the uptake of iron increases eightfold relative to the uptake of pyrophosphate. 5. The results are compatible with a model in which ferric iron is mobilized from transferrin by pyrophosphate, ferric iron pyrophosphate is bound to the mitochondria, iron is reduced, dissociates from pyrophosphate and is taken up by the mitochondria. Ferrous irons thus formed is available for heme synthesis. (orig.) [de

  9. Oxidative dehydrogenation of isobutane over a titanium pyrophosphate catalyst

    Directory of Open Access Journals (Sweden)

    IOAN-CEZAR MARCU

    2005-06-01

    Full Text Available The catalytic properties of titanium pyrophosphate in the oxidative dehydrogenation of isobutane to isobutylene were investigated in the 400 – 550 ºC temperature range. Asignificant change of the product distribution and of the apparent activation energy of the reactionwas observed at about 490 ºC. This phenomenon, already observed in the oxidative dehydrogenation of n-butane, has been interpreted by the existence of two reaction mechanisms depending upon the reaction temperature. Comparison with the n-butane reaction allowed different activation pathways for the activation of alkanes to be proposed. The catalytic properties of TiP2O7 in the oxidative dehydrogenation of isobutane was also compared to those obtained previously with several other pyrophosphates and TiP2O7 was found to be less active and selective for this reaction.

  10. Insolubilization of technetium by microorganisms in waterlogged soils

    International Nuclear Information System (INIS)

    Ishii, Nobuyoshi; Tagami, Keiko

    2003-01-01

    In order to clarify the technetium behavior in paddy field ecosystem, insolubilization of technetium in the water covering waterlogged soils was studied. Fourteen soils collected from paddy fields (9 samples) and upland fields (5 samples) were waterlogged for 7 days. After the collection of water covering the waterlogged soils, a radio tracer 95m TcO 4 - was added to the water. After 4 days incubation of the water, the tracer was separated into four fractions: insoluble, pertechnetate, cationic, and other forms of technetium. On an average, 13% of the 95m TcO 4 - changed to insoluble forms and the maximum ratio of the insolubilization was 76%. This result shows that insolubilization of technetium can occur in the water covering the waterlogged soils. Subsequently, mechanisms of Tc insolubilization were studied using the sample that showed the maximum insolubilization of Tc among the soil samples. When microorganisms were removed from the water by filtration, insoluble forms of Tc decreased to 3.6%. In contrast, the insolubilization ratio increased to 86% by the addition of organic substrates. The insolubilization, therefore, was caused by microorganisms. Furthermore, the addition of antibiotics on bacteria resulted in 23% of the insolubilization, while the antibiotic on fungi did not affect on the insolubilization. If the insolubilization were caused by biosorption, the insolubilization ratio would not decrease for the sample added antibiotics on bacteria. Therefore, these results suggest that the insolubilization of technetium is caused by bioaccumulation of living bacteria. Because the cultures with 95m TcO 4 - were incubated under aerobic conditions, technetium-insolubilizing microorganisms would presumably be aerobic bacteria. (author)

  11. Experimental measurements of the solubility of technetium under near-field conditions

    International Nuclear Information System (INIS)

    Pilkington, N.J.; Wilkins, J.D.

    1988-05-01

    The solubility of technetium in contact with hydrated technetium dioxide under near-field conditions has been measured experimentally. The values obtained were changed little by a change in pH or in the filtration method used. The presence of organic degradation products increased slightly the solution concentration of technetium. (author)

  12. Technetium sorption by stibnite from natural water

    International Nuclear Information System (INIS)

    Peretroukhine, V.; Sergeant, C.; Deves, G.; Poulain, S.; Vesvres, M.H.; Thomas, B.; Simonoff, M.

    2006-01-01

    The sorption of technetium by powdered and polished mineral stibnite Sb 2 S 3 has been investigated in simulated and natural underground waters from the Meuse/Haute-Marne region (France). The sorption by powdered stibnite has been found to be complete under both aerobic and anaerobic conditions in batch experiments. The sorption rate is higher in the absence of oxygen than under aerobic condition. Increasing the temperature from 30 C to 60 C results in a rise of the sorption rate by 9.1 and 27 times under anaerobic and aerobic conditions, respectively. The observed differences in sorption kinetics in the presence and in absence of oxygen are explained by the interaction of oxygen with sulfide ion in aerobic conditions and by the reduction of technetium(VII) by iron(II) and by other impurities present in natural water and in the mineral, and by the subsequent sorption of Tc(IV) on stibnite under anaerobic conditions. The sorption on a polished mineral surface resulted in the formation of a technetium film, probably Tc 2 S 7 , with a thickness of 1-3 μg Tc/cm 2 pH 3-6 and 4-12 μg Tc/cm 2 at 9-12. The simultaneous formation of stibnite colloids with adsorbed technetium occurs at pH 9-12. The study of the technetium film on the mineral by proton induced X-ray emission analysis showed it to be at least one order of magnitude thinner on the SiO 2 impurities than on the main Sb 2 S 3 component and the iron impurities. (orig.)

  13. Sorption characteristics of technetium on crosslinked chitosan from aqueous solution

    International Nuclear Information System (INIS)

    Pivarciova, L.; Rosskopfova, O.; Galambos, M.; Rajec, P.

    2014-01-01

    Sorption of technetium on crosslinked chitosan was studied using batch techniques in static arrangement of experiment under aerobic conditions at laboratory temperature. The adsorption of technetium was rapid and the percentage of the technetium sorption was > 98 %. In the pH range of 3-11 adsorption of technetium on crosslinked chitosan was > 98 %. The competition effect of Fe 3+ towards TcO 4 - sorption on crosslinked chitosan was stronger than the competition effect of other observed cations. The selectivity of crosslinked chitosan for these cations in solution with the concentration above 1·10 -3 mol·dm -3 was in the order Fe 3+ > Ca 2+ > Na + > Fe 2+ . The competition effect of (ClO 4 ) - towards TcO 4 - sorption was stronger than the competition effect of (SO 4 ) 2 - ions. From these results it can be expected that crosslinked chitosan could be a suitable sorbent for the immobilization of technetium in the liquid radioactive waste. (authors)

  14. Assessment of Technetium in the Savannah River Site Environment

    International Nuclear Information System (INIS)

    Carlton, W.H.; Denham, M.; Evans, A.G.

    1993-07-01

    Assessment of Technetium in the Savannah River Site Environment is the last in a series of eight documents on individual radioisotopes released to the environment as a result of SRS operations. The earlier documents describe the environmental consequences of tritium cesium, iodine, uranium plutonium, strontium, and carbon. Technetium transport and metabolism have been studied by the nuclear industry because it is a fission product of uranium, and by the medical community because 99m Tc commonly is used as a diagnostic imaging agent in nuclear medicine. Technetium has been produced at SRS during the operation of five production reactors. The only isotope with environmental significance is 99 Tc. Because of the small activities of 99 Tc relative to other fission products, such as 90 Sr and 137 Cs, no measurements were made of releases to either the atmosphere or surface waters. Dose calculations were made in this document using conservative estimates of atmospheric releases and from a few measurements of 99 Tc concentrations in the Savannah River. Technetium in groundwater has been found principally in the vicinity of the separation areas seepage basins. Technetium is soluble in water and follows groundwater flow with little retardation. While most groundwater samples are negative or show little technetium a few samples have levels slightly above the limits set by the EPA for drinking water. The overall radiological impact of SRS 99 Tc releases on the offsite maximally exposed individual during 38 years of operations can be characterized by maximum individual doses of 0.1 mrem (atmospheric) and 0.8 mrem (liquid), compared with a dose of 13,680 mrem from non-SRS sources during the same time period. Technetium releases have resulted in a negligible risk to the environment and the population it supports

  15. Radioisotope spleen scan in patients with splenic injury

    International Nuclear Information System (INIS)

    Mishalany, H.G.; Miller, J.H.; Woolley, M.M.

    1982-01-01

    The technetium /sup 99m/Tc sulfur colloid liver-spleen scan is a valuable aid in diagnosis and treatment of patients with splenic injury. After reviewing the charts of 47 patients who were ill as a result of splenic trauma, we came to the following conclusions: (1) the scan identified the injury, accurately mapped its extent, and indicated the presence or absence of associated liver injuries; (2) the scans were useful in following the extent and rate of healing of the splenic injury; (3) the scan is an indirect measurement of of return of splenic fuction; (4) the procedure can be performed in a reasonable time frame with no serious morbidity; and (5) the indications, contraindications, and timing of scans are now reasonably well established

  16. Radioisotope spleen scan in patients with splenic injury

    Energy Technology Data Exchange (ETDEWEB)

    Mishalany, H.G.; Miller, J.H.; Woolley, M.M.

    1982-09-01

    The technetium /sup 99m/Tc sulfur colloid liver-spleen scan is a valuable aid in diagnosis and treatment of patients with splenic injury. After reviewing the charts of 47 patients who were ill as a result of splenic trauma, we came to the following conclusions: (1) the scan identified the injury, accurately mapped its extent, and indicated the presence or absence of associated liver injuries; (2) the scans were useful in following the extent and rate of healing of the splenic injury; (3) the scan is an indirect measurement of of return of splenic fuction; (4) the procedure can be performed in a reasonable time frame with no serious morbidity; and (5) the indications, contraindications, and timing of scans are now reasonably well established.

  17. Fluorido complexes of technetium

    Energy Technology Data Exchange (ETDEWEB)

    Mariappan Balasekaran, Samundeeswari

    2013-07-04

    Fluorine chemistry has received considerable interest during recent years due to its significant role in the life sciences, especially for drug development. Despite the great nuclear medicinal importance of the radioactive metal technetium in radiopharmaceuticals, its coordination chemistry with the fluorido ligand is by far less explored than that of other ligands. Up to now, only a few technetium fluorides are known. This thesis contains the synthesis, spectroscopic and structural characterization of novel technetium fluorides in the oxidation states ''+1'', ''+2'', ''+4'' and ''+6''. In the oxidation state ''+6'', the fluoridotechnetates were synthesized either from nitridotechnetic(VI) acid or from pertechnetate by using reducing agent and have been isolated as cesium or tetraethylammonium salts. The compounds were characterized spectroscopically and structurally. In the intermediate oxidation state ''+4'', hexafluoridotechnetate(IV) was known for long time and studied spectroscopically. This thesis reports novel and improved syntheses and solved the critical issues of early publications such as the color, some spectroscopic properties and the structure of this key compound. Single crystal analyses of alkali metal, ammonium and tetramethylammonium salts of hexafluoridotechnetate(IV) are presented. In aqueous alkaline solutions, the ammonium salt of hexafluoridotechnetate(IV) undergoes hydrolysis and forms an oxido-bridged dimeric complex. It is the first step hydrolysis product of hexafluoridotechnetate(IV) and was characterized by spectroscopic and crystallographic methods. Low-valent technetium fluorides with the metal in the oxidation states of ''+2'' or ''+1'' are almost unknown. A detailed description of the synthesis and characterization of pentafluoridonitrosyltechnetate(II) is presented. The

  18. Preparation and in vivo biological investigations on a novel radioligand for bone scanning: technetium-99m-labeled zoledronic acid derivative

    International Nuclear Information System (INIS)

    Lin Jianguo; Qiu Ling; Cheng Wen; Luo Shineng; Ye Wanzhong

    2011-01-01

    Introduction: To enable imaging at an earlier time after injection, a radiopharmaceutical with higher affinity for bone, larger ratio of bone-to-soft tissue uptake and more rapid clearance from blood is required. The nature of diphosphonic acid is a key factor to determine the advantages of the radiopharmaceuticals. The purpose of this study is to optimize the linker chain between the imidazolyl and geminal diphosphonate group in the zoledronic acid (ZL) to develop novel single photon emission computed tomography (SPECT) bone imaging agent. Methods: A novel ZL derivative, 1-hydroxy-3-(1H-imidazol-1-yl)propane-1,1-diyldiphosphonic acid (IPrDP), was successfully prepared and labeled with 99m Tc in a high labeling yield. Biodistribution of 99m Tc-IPrDP and 99m Tc-ZL in normal mice were studied and compared. SPECT bone scanning was performed on the rabbit and a series of dynamic and static images were recorded by Philips SKY Light emission computed tomography. Results: In the biodistribution studies, 99m Tc-IPrDP exhibits significant advantages on the bone resorption and the clearance from soft tissues compared with 99m Tc-ZL. Kinetics of blood clearance in mice showed that T 1/2α and T 1/2β of 99m Tc-IPrDP were 1.47 min and 46.47 min, while those of 99m Tc-ZL were 2.28 and 52.63 min respectively. Excellent images of the rabbit skeleton can be quickly obtained for 99m Tc-IPrDP, which was faster than 99m Tc-ZL and the clinically widely used bone imaging agent 99m Tc-MDP (technetium-99m labeled with methylenediphosphonate). Conclusions: 99m Tc-IPrDP possesses excellent characteristics for the potential application as a novel bone scanning agent.

  19. Nitrido-technetium(V) complexes with amino acids: Preparation and X-ray crystal structure of the L-cysteinate ethyl ester technetium(V) complex

    International Nuclear Information System (INIS)

    Marchi, A.; Rossi, R.; Marvelli, L.; Bertolasi, V.

    1993-01-01

    Technetium-99m is the radionuclide of choice in diagnostic nuclear medicine due to its ideal photon energy of 140 keV and half-life of 6 h. Neutral, stable, and lipophilic technetium complexes with diamino dithiol ligands (DADT) have been widely studied as potential brain perfusion agents and a 99m Tc complex of N,N'-1,2-ethylenediylbis(L-cysteine diethyl ester) (L,L-ECD) has been proposed as a marker of regional cerebral blood flow. It crosses the blood brain barrier (BBB) and is retained in the brain owing to enzymatic hydrolysis of one ester group yielding to a more polar species. More recently, 99m Tc-cysteine complex has been evaluated in animal distribution studies for tumor diagnosis, but its chemical structure has not been determined. A large number of transition metal complexes with amino acids and peptides have been synthesized and structurally characterized to understand their interactions with proteins and antibodies, as well as biocatalytic processes, but only a limited number of rhenium and technetium compounds have been reported. Up to now, the only technetium complex to be characterized by X-ray analysis that contains amino acids as ligand is [TcO(L,L-ECD)]. The author's interest in the nitrido-technetium chemistry is due to the discovery of a new method for preparing radiopharmaceuticals containing the [ 99m Tc triple-bond N] 2+ core. In this communication the authors report the synthesis and characterization of nitrido-technetium complexes with L-cysteine ethyl ester (CYS-OEt), L-cysteine (CYS) and cysteamine (CSA) and the first X-ray crystal structure of a [TcN] 2+ -amino acid complex

  20. Successful application of technetium-99m-labeled octreotide acetate scintigraphy in the detection of ectopic adrenocorticotropin-producing bronchial carcinoid lung tumor: a case report

    Directory of Open Access Journals (Sweden)

    Fallahi Babak

    2010-10-01

    Full Text Available Abstract Introduction The diagnostic efficacy of somatostatin receptor scintigraphy labeling with 111 indium in the localization of tumors has been assessed in a limited number of patients with contradictory outcomes. Here, we describe the case of a patient with an ectopic adrenocorticotropic hormone-producing bronchial carcinoid tumor diagnosed preoperatively using technetium-99m-labeled octreotide acetate scintigraphy. Case presentation A 29-year-old Asian man presented to our hospital with the typical clinical features of Cushing's syndrome, which he had had for a duration of 18 months. The results of a biochemical evaluation revealed he had adrenocorticotropic hormone-dependent Cushing's syndrome. The results of a spiral abdominal computed tomography scan showed he had bilateral adrenal hypertrophy. A magnetic resonance image of the patient's brain showed he had a normal hypophysis. Whole body technetium-99m-labeled octreotide acetate scintigraphy was performed to check for the presence of an ectopic adrenocorticotropic hormone-producing tumor. The scan results showed a small focal increase in uptake in the lower lobe of our patient's right lung, just above his diaphragm. A spiral chest computed tomography scan also revealed a small non-specific lesion in the same region. A transthoracic biopsy was then performed. Pathological evaluation confirmed the diagnosis of a carcinoid tumor, of the adrenocorticotropic hormone-producing type. After surgical removal, the patient's symptoms resolved and significant clinical improvement was achieved. Conclusions This case report shows that technetium-99m-labeled octreotide acetate scintigraphy can effectively detect an ectopic adrenocorticotropic hormone-producing bronchial carcinoid.

  1. Technetium-99m labeled radiodiagnostic agents and method of preparation

    International Nuclear Information System (INIS)

    Molinski, V.J.; Wilczewski, J.A.

    1977-01-01

    A method of preparing improved technetium-99m labeled radiodiagnostic agents by reducing technetium-99m with stannous tartrate is described. Such radiodiagnostic agents are useful in scintigraphic examinations of the bone and lung

  2. Technetium removal from aqueous wastes

    International Nuclear Information System (INIS)

    Fletcher, P.A.; Jones, C.P.; Junkison, A.R.; Turner, A.D.; Kavanagh, P.R.

    1992-03-01

    The research discussed in this report has compared several ''state of the art'' techniques for the removal of traces of the radionuclide, technetium, from aqueous wastes. The techniques investigated were: electrochemical reduction to an insoluble oxide, electrochemical ion exchange, seeded ultrafiltration and chemical reduction followed by filtration. Each technique was examined using a simulant based upon the waste generated by the Enhanced Actinide Removal Plant (EARP) at Sellafield. The technique selected for further investigation was direct electrochemical reduction which offers an ideal route for the removal of technetium from the stream (DFs 10-100) and can be operated continuously with a low power consumption 25 kW for the waste generated by EARP. Cell designs for scale up have been suggested to treat the 1000m 3 of waste produced every day. Future work is proposed to investigate the simultaneous removal of other key radionuclides, such as ruthenium, plutonium and cobalt as well as scale up of the resulting process and to investigate the effect of these other radionuclides on the efficiency of the electrochemical reduction technique for the removal of technetium. Total development and full scale plant costs are estimated to be of the order of 5 pounds - 10M, with a time scale of 5 -8 years to realisation. (author)

  3. Investigation on chemistry of model compounds of technetium radiopharmaceuticals

    International Nuclear Information System (INIS)

    Muenze, R.; Hartmann, E.

    1983-01-01

    The report summarized experimental and theoretical results concerning the chemical structures and the biodistribution of hydrophilic technetium chelates with hydroxycarboxylic and aminopolycarboxylic acids, thiol compounds and aliphatic and aromatic nitrogen compounds as ligands. Methods which are suitable for synthesizing and characterizing defined chelates of Tc(V), Tc(IV) and Tc(III) have been developed for crystlline substances and species in solution, respectively. For certain types of technetium chelates three dimensional structure models were calculated from atomic parameters. The electron energies and electron distribution of Tc(V) thiol compounds were calculated by quantum chemical methods in order to interprete physical properties of these substances. Biodistribution studies revealed relationships between the osteotropic behaviour and the structure of phosphorous and non-phosphorous technetium chelates and between the kidney uptake and ligand exchange ability of Tc(V) hydroxycarboxylates. Important parameters for the production of technetium-99m kits have been elaborated and used for the optimization of radiopharmaceuticals (bone-, kidney and hepatobiliaer agents). (author)

  4. Technetium SPECT agents for imaging heart and brain

    International Nuclear Information System (INIS)

    Linder, K.E.

    1990-01-01

    One major goal of radiopharmaceutical research has been the development of technetium-based perfusion tracers for SPECT imaging of the heart and brain. The recent clinical introduction of the technetium complexes HM-PAO, ECD and DMG-2MP for brain imaging, and of CDO-MEB and MIBI for heart imaging promises to revolutionize the field of nuclear medicine. All of these agents appear to localize in the target tissue in proportion to blood flow, but their mechanisms of localization and/or retention may differ quite widely. In this talk, a survey of the new technetium SPECT agents will be presented. The inorganic and biological chemistry of these complexes, mechanisms of uptake and retention, QSAR studies, and potential clinical applications are discussed

  5. Uptake and localization of sup(99m)technetium-methylene-diphosphonate in bone

    International Nuclear Information System (INIS)

    Savelkoul, T.J.F.

    1984-01-01

    The author investigated the uptake and localization of 99m-technetium-methylene-diphosphonate (99m-Tc-MDP) in bone, to develop a sensitive mean for the detection of early osseous disease. In an electrolysis procedure without the presence of contaminating reductants a 99m-Tc-MDP complex is formed with clear bone-seeking properties. The scans performed in experimental animals are comparable in quality with 99m-Tc(Sn)-MDP scans. The uptake of 99m-Tc-MDP is faster and higher than the uptake of reduced hydrolyzed 99m-Tc. Uptake of 99m-Tc(Sn)-MDP in bone can only take place after decomposition of the complex. As 99m-Tc-MDP is taken up as a unit, this may be a better agent to evaluate the osteoblastic activity in the skeleton. (Auth./R.B.)

  6. Method of stably radiolabeling antibodies with technetium and rhenium

    International Nuclear Information System (INIS)

    Paik, C.H.; Reba, R.C.; Eckelman, W.C.

    1987-01-01

    A method is described for labeling antibodies or antibody fragments with radionuclides of technetium or rhenium to obtain stable labeling, comprising: reacting a reduced radioisotope of technetium or rhenium with an antibody or antibody fragment, or a diethylenetriaminepentaacetic acid conjugated antibody or antibody fragment, in the presence of free or carrier-bound diethylenetriaminepentaacetic acid (DTPA). The amount of DTPA is sufficient to substantially completely inhibit binding of the reduced technetium or rhenium to nonstable binding sites of the antibody or antibody fragment, or the DTPA-conjugated antibody or antibody fragment. The resultant stably labeled antibody or antibody fragment, or DTPA[conjugated antibody or antibody fragment is recovered

  7. Stress reactions involving the pars interarticularis in young athletes

    Energy Technology Data Exchange (ETDEWEB)

    Jackson, D.W.; Wiltse, L.L.; Dingeman, R.D.; Hayes, M.

    A stress reaction involving the pars interarticularis of the lumbar spine was confirmed in seven young athletes with a positive technetium pyrophosphate bone scan. No pars defects were detectable on their lumbosacral roentgenograms, which included oblique views. The return to normal levels of radioactive uptake on repeat bone scans correlated closely with their clinical course. If the bony reaction is recognized early, it may heal at a subroentgenographic level and prevent the development of lumbar spondylolysis. These early lesions usually show unilateral increased uptake at one lumbar level on the bone scan and, initially, the athlete localizes the pain to the corresponding unilateral lumbar paraspinous area. The ''one-legged hyperextension test'' is positive on the ipsilateral side and aggravates the pain. Treatment consists of avoiding the aggravating activities and resting. The average time for return to pain-free competition was 7.3 months. These developing defects may be the source of considerable prolonged disability in the young athlete, particularly if undiagnosed and untreated.

  8. Stress reactions involving the pars interarticularis in young athletes

    International Nuclear Information System (INIS)

    Jackson, D.W.; Wiltse, L.L.; Dingeman, R.D.; Hayes, M.

    1981-01-01

    A stress reaction involving the pars interarticularis of the lumbar spine was confirmed in seven young athletes with a positive technetium pyrophosphate bone scan. No pars defects were detectable on their lumbosacral roentgenograms, which included oblique views. The return to normal levels of radioactive uptake on repeat bone scans correlated closely with their clinical course. If the bony reaction is recognized early, it may heal at a subroentgenographic level and prevent the development of lumbar spondylolysis. These early lesions usually show unilateral increased uptake at one lumbar level on the bone scan and, initially, the athlete localizes the pain to the corresponding unilateral lumbar paraspinous area. The ''one-legged hyperextension test'' is positive on the ipsilateral side and aggravates the pain. Treatment consists of avoiding the aggravating activities and resting. The average time for return to pain-free competition was 7.3 months. These developing defects may be the source of considerable prolonged disability in the young athlete, particularly if undiagnosed and untreated

  9. Radiation decomposition of technetium-99m radiopharmaceuticals

    International Nuclear Information System (INIS)

    Billinghurst, M.W.; Rempel, S.; Westendorf, B.A.

    1979-01-01

    Technetium-99m radiopharmaceuticals are shown to be subject to autoradiation-induced decomposition, which results in increasing abundance of pertechnetate in the preparation. This autodecomposition is catalyzed by the presence of oxygen, although the removal of oxygen does not prevent its occurrence. The initial appearance of pertechnetate in the radiopharmaceutical is shown to be a function of the amount of radioactivity, the quantity of stannous ion used, and the ratio of /sup 99m/Tc to total technetium in the preparation

  10. Thallium-201 and technetium-99m pertechnetate subtraction scintigraphy in patients with hyperparathyroidism

    International Nuclear Information System (INIS)

    Kuwashima, Shigeko; Koizumi, Mitsuru; Goto, Masafumi; Nomura, Toshiharu; Fujioka, Mutsuhisa; Watari, Tsutomu

    1992-01-01

    A reliable technique for detecting and localizing abnormal parathyroid tissue has been a persistent problem. We evaluated thallium-technetium (Tl/Tc) subtraction scintigraphy in 16 patients with clinical biochemical evidence of hyperparathyroidism prior to other diagnostic methods and surgery. Seven patients had surgery and were confirmed to have parathyroid adenoma or hyperplasia. The other methods included ultrasonography (US) in 6 patients, computed tomography (CT) in 10 patients, magnetic resonance imaging (MRI) in 8 patients, and bone scintigraphy in 7 patients. In patients who had several imaging modalities, the detection rate was significantly better for Tl/Tc subtraction scan than for US, CT or MRI. Bote scintigraphy, though not so sensitive as Tl/Tc subtraction studies, was an important tool for evaluating metabolic bone disorder including hyperparathyroidism and renal osteodystrophy. Thus, Tl/Tc subtraction scan is more useful for diagnosis when hyperparathyroidism is suspected if both Tl/Tc subtraction scan and bone scan are performed. The detectability depended on the mass size, and detection of abnormal glands was greater for adenoma than for hyperplasia. The results suggest that Tl/Tc subtraction scan is a simple, non-invasive and useful tool for locating parathyroid abnormality even when compared with MRI. (author)

  11. Scintimetric assessment of synovitis activity during treatment with disease modifying antirheumatic drugs

    DEFF Research Database (Denmark)

    Olsen, N; Halberg, P; Halskov, O

    1988-01-01

    In a double blind trial of 36 patients with rheumatoid arthritis a new scintimetric method was applied to three comparable patient groups before and after eight months' treatment with levamisole, penicillamine, or azathioprine. Technetium-99m pyrophosphate scintigraphy of both hands was performed...

  12. Postcountershock myocardial damage after pretreatment with adrenergic and calcium channel antagonists in halothane-anesthetized dogs

    Energy Technology Data Exchange (ETDEWEB)

    Gaba, D.M.; Metz, S.; Maze, M.

    1985-05-01

    Transthoracic electric countershock can cause necrotic myocardial lesions in humans as well as experimental animals. The authors investigated the effect on postcountershock myocardial damage of pretreatment with prazosin, an alpha-1 antagonist; L-metoprolol, a beta-1 antagonist, and verapamil, a calcium channel-blocking agent. Twenty dogs were anesthetized with halothane and given two transthoracic countershocks of 295 delivered joules each after drug or vehicle treatment. Myocardial injury was quantitated 24 h following countershock by measuring the uptake of technetium-99m pyrophosphate in the myocardium. Elevated technetium-99m pyrophosphate uptake occurred in visible lesions in most dogs regardless of drug treatment. For each of four parameters of myocardial damage there was no statistically significant difference between control animals and those treated with prazosin, metoprolol, or verapamil. These data suggest that adrenergic or calcium channel-mediated mechanisms are not involved in the pathogenesis of postcountershock myocardial damage.

  13. Bone scans

    International Nuclear Information System (INIS)

    Hetherington, V.J.

    1989-01-01

    Oftentimes, in managing podiatric complaints, clinical and conventional radiographic techniques are insufficient in determining a patient's problem. This is especially true in the early stages of bone infection. Bone scanning or imaging can provide additional information in the diagnosis of the disorder. However, bone scans are not specific and must be correlated with clinical, radiographic, and laboratory evaluation. In other words, bone scanning does not provide the diagnosis but is an important bit of information aiding in the process of diagnosis. The more useful radionuclides in skeletal imaging are technetium phosphate complexes and gallium citrate. These compounds are administered intravenously and are detected at specific time intervals postinjection by a rectilinear scanner with minification is used and the entire skeleton can be imaged from head to toe. Minification allows visualization of the entire skeleton in a single image. A gamma camera can concentrate on an isolated area. However, it requires multiple views to complete the whole skeletal image. Recent advances have allowed computer augmentation of the data received from radionucleotide imaging. The purpose of this chapter is to present the current radionuclides clinically useful in podiatric patients

  14. The incorporation of technetium into a representative low-activity waste glass

    International Nuclear Information System (INIS)

    Ebert, W.L.; Bakel, A.J.; Bowers, D.L.; Buck, E.C.; Emery, J.W.

    1997-01-01

    A glass that has been tested to understand the corrosion behavior of waste glasses with high soda contents for immobilizing Hanford incidental wastes has been made by melting crushed glass with either TcO 2 or NaTcO 4 at 1,100--1,300 C. Incorporation of technetium in the glass was affected by solubility or kinetic effects. Metallic technetium inclusions formed in all the TcO 2 -doped glasses. Inclusions also formed in glasses with added NaTcO 4 that were melted at 1,100 C, but a glass melted at 1,200 C did not contain detectable inclusions. The presence of Tc-bearing inclusions complicates the interpretation of results from dissolution tests because of the simultaneous release of technetium from more than one phase, the unknown surface areas of each phase, and the possible incorporation of technetium that is released from one phase into another phase. A glass containing about 0.15 mass % Tc dissolved in the glass is being used in dissolution tests to study the release behavior of technetium

  15. Radionuclide bone scanning of medullary chondrosarcoma

    International Nuclear Information System (INIS)

    Hudson, T.M.; Chew, F.S.; Manaster, B.J.

    1982-01-01

    Technetium-99m methylene diphosphonate bone scans of 18 medullary chondrosarcomas of bone were correlated with pathologic macrosections of the resected tumors. There was increased scan intake by all 18 tumors, and the uptake in 15 scans corresponded accurately to the anatomic extent of the tumors. Only three scans displayed increased uptake beyond the true tumor margins; thus, the ''extended pattern of uptake'' beyond the true tumor extent is much less common in medullary chondrosarcomas than in many other primary bone tumors. Therefore, increased uptake beyond the apparent radiographic margin of the tumor suggests possible occult tumor spread. Pathologically, there was intense reactive new bone formation and hyperemia around the periphery of all 18 tumors, and there were foci of enchondral ossification, hyperemia, or calcification within the tumor itself in nearly every tumor. Three scans displayed less uptake in the center of the tumors than around their peripheries. One of these tumors was necrotic in the center, but the other two were pathologically no different from tumors that displayed homogenous uptake on the scan

  16. Bronchoalveolar lavage and technetium-99m glucoheptonate imaging in chronic eosinophilic pneumonia

    International Nuclear Information System (INIS)

    Lieske, T.R.; Sunderrajan, E.V.; Passamonte, P.M.

    1984-01-01

    A patient with chronic eosinophilic pneumonia was evaluated using bronchoalveolar lavage, technetium-99m glucoheptonate, and transbronchial lung biopsy. Bronchoalveolar lavage revealed 43 percent eosinophils and correlated well with results of transbronchial lung biopsy. Technetium-99m glucoheptonate lung imaging demonstrated intense parenchymal uptake. After eight weeks of corticosteroid therapy, the bronchoalveolar lavage eosinophil population and the technetium-99m glucoheptonate uptake had returned to normal. We suggest that bronchoalveolar lavage, with transbronchial lung biopsy, is a less invasive way than open lung biopsy to diagnose chronic eosinophilic pneumonia. The mechanism of uptake of technetium-99m glucoheptonate in this disorder remains to be defined

  17. Accelerators for forming cationic technetium complexes useful as radiodiagnostic images

    International Nuclear Information System (INIS)

    Tweedle, M.F.

    1985-01-01

    This invention relates to compositions for making cationic radiodiagnostic agents and, in particular, to accelerator compounds for labelling such cationic radiodiagnostic agents, kits for preparing such 99m Tc-labelled cationic radiodiagnostic agents with technetium, and methods for labelling such cationic radiodiagnostic agents with technetium

  18. Highvalent and organometallic technetium and rhenium compounds

    International Nuclear Information System (INIS)

    Oehlke, Elisabeth

    2010-01-01

    Diagnostic methods in nuclear medicine allow a detailed description of morphological organ structures and their function. The beta emitting isotope Tc-99 has optimal physical properties (140 keV gamma rays, half-life 6 h) and is therefore used for radiopharmaceuticals. The thesis is concerned with the search for new technetium complexes and their reproducible production. The (TcO3) core is of main interest. The second part of the thesis deals with organometallic technetium and rhenium complexes with carbonyl ligands and N-heterocyclic carbenes that show stability in aerobic aqueous solutions.

  19. Absorption of technetium by plants in relation to soil type contamination level and time

    Energy Technology Data Exchange (ETDEWEB)

    Mousny, J.M.; Myttenaere, C. (Louvain Univ. (Belgium). Lab. de Physiologie Vegetale)

    1981-01-01

    Plants of Pisum sativum (var. Merveille de Kelvedon) were grown on seven typical european soils contaminated with different levels of /sup 99/Tc(0.17; 1.7 and 17 ..mu..Ci/kg). Added initially as pertechnetate, the technetium absorption has been studied for three successive cultures. The translocation of technetium from soil to plant leaves is high, but its transfer is reduced in soils rich in organic matter (Fen) or poorly drained (Braunerde). Aging reduces the technetium transfer and modify its relative distribution in plant (relatively more technetium is found in fruits); these results let suppose some modification of the technetium chemical form in soils with time.

  20. Binuclear complexes of technetium. Evidence for bis(terdentate)bidentate coordination by the bridging ligand 2,3,5,6-tetrakis(2-pyridyl)pyrazine to technetium(V)

    International Nuclear Information System (INIS)

    Du Preez, J.G.H.; Gerber, T.I.A.; Gibson, M.L.; Geyser, R.

    1990-01-01

    The authors have used the potentially bis(terdentate) nitrogen aromatic heterocyclic ligand 2,3,5,6-tetrakis(2-pyridyl)pyrazine (tppz) to prepare mono- and bimetallic technetium(V) complexes bound to tppz. The stimulus for the development of the coordination chemistry of the man-made element technetium is provided by the use of complexes of this element as anatomical imaging agents in nuclear medicine. Although the chemistry of technetium(V) with nitrogen donor ligands is well understood, no complexes have been prepared using potentially terdentate neutral nitrogen donor ligands of this metal in the +5 oxidation state

  1. Studies of technetium chemistry. Pt.8. The regularities of the bond length and configuration of rhenium and technetium complexes in crystals

    International Nuclear Information System (INIS)

    Liu Guozheng; Liu Boli

    1995-01-01

    Some bond length regularities in MO 6 , MO-4, MX 5 α and MX 4 αβ moieties of technetium and rhenium compounds are summarized and rationalized by cavity model. The chemical properties of technetium and rhenium are so similar that their corresponding complexes have almost the same configuration and M-X bond lengths when they are in cavity-controlled state. Technetium and Rhenium combine preferably with N, O, F, S, Cl and Br when they are in higher oxidation states (>3), but preferably with P, Se etc. when they are in lower oxidation states ( 4 αβ is approximately constant; (2) the average M-X bond length of MX 6 varies moderately with the oxidation state of M; (3) the bond length of M-X trans to M-α in MX 5 α has a linear relationship with the angle

  2. Calcium pyrophosphate deposition disease: clinical manifestations

    Directory of Open Access Journals (Sweden)

    M.A. Cimmino

    2012-01-01

    Full Text Available Calcium pyrophosphate deposition (CPPD disease is an arthropathy caused by calcium pyrophosphate dihydrate (CPP crystal deposits in articular tissues, most commonly fibrocartilage and hyaline cartilage. According to EULAR, four different clinical presentations can be observed: 1 asymptomatic CPPD; 2 osteoarthritis (OA with CPPD; 3 acute CPP crystal arthritis; 4 chronic CPP inflammatory crystal arthritis. Acute CPP crystal arthritis is characterized by sudden onset of pain, swelling and tenderness with overlying erythema, usually in a large joint, most often the knee, wrist, shoulder, and hip. Occasionally, ligaments, tendons, bursae, bone and the spine can be involved. CPPD of the atlanto-occipital joint (crowned dens syndrome can cause periodic acute cervico-occipital pain with fever, neck stiffness and laboratory inflammatory syndrome. Chronic inflammatory arthritis is characterized by joint swelling, morning stiffness, pain, and high ESR and CRP. The relationship between OA and CPPD is still unclear. The main problem is whether such crystals are directly involved in the pathogenesis of OA or if they are the result of joint degeneration. Diagnosis is based on evaluation of history and clinical features, conventional radiology, and synovial fluid examination. Non-polarized light microscopy should be used initially to screen for CPPD crystals based upon their characteristic morphology, and compensated polarized light microscopy, showing the crystals to be weakly positive birefringent, is recommended for definitive identification, although this last pattern only occurs in about 20% of samples. The main goals of CPPD therapy are control of the acute or chronic inflammatory reaction and prevention of further episodes.

  3. The quality control of technetium-99m radiopharmaceuticals produced at the AAEC Research Establishment

    International Nuclear Information System (INIS)

    Farrington, K.J.

    1983-08-01

    The methods of quality control used for technetium-99m radiopharmaceuticals produced at the AAEC Research Establishment are described for both non-fission and fission derived sources of sodium pertechnetate, technetium-99m labelled radipopharmaceuticals, and reagent kits produced for technetium-99m labelling

  4. The radiopharmaceuticals labelled with technetium-99m and the radiopharmacy

    International Nuclear Information System (INIS)

    Bodenant, V.

    1998-01-01

    In less than fifty years, the place of nuclear medicine is become primordial. Among all the radiopharmaceuticals used in nuclear medicine, the technetium-99m is the most used because of its physico-chemical properties and its great availability with the molybdenum-99m - technetium-99m generator. Since 1992, the radiopharmaceuticals, the packages, the generators are included in the pharmaceutic monopole. They are now under the reliability of the radio-pharmacist. This thesis has for object to introduce these different radiopharmaceuticals labelled with technetium-99m and to show the primordial place of the radio-pharmacist in a service of nuclear medicine. (N.C.)

  5. Electrochemical preparation of technetium hydroxyethylidene diphosphonate radiopharmaceuticals

    International Nuclear Information System (INIS)

    Scott, R.B.

    1984-01-01

    This work describes the liquid chromatographic and electrochemical analysis of electrogenerated technetium hydroxyethylidene diphosphonate (HEDP) complexes, and studies the effectiveness of the resulting bone imaging agents. Anion exchange High Performance Liquid Chromatography is used to separate components, and γ emission is used as the detection mode. The reaction mixtures were prepared at a series of reduction potentials and pH values, at both carrier added and no carrier added technetium levels. The results indicate that all three parameters affect the final complex composition to varying degrees. By optimizing the conditions, a preparation was made which results in a high percentage of a Tc-HEDP complex thought to be a very good home imager. This component was isolated chromatographically and injected into female Sprague-Dawley rats. Comparisons were run on the uptake for seven tissue types at two incubation times. Mercury and Reticulated Vitreous Carbon were used as the working electrode materials, and it is shown how reduced technetium will significantly alter the electrode characteristics, where a conditioned electrode will produce different complexes from those produced at fresh electrode material. By employing coulometric analysis as the preparation was reduced, an n value of 4 was calculated for a particular complex. This procedure involved tracking the radioactive technetium species carefully to account for all electrons used in the system. Finally, an electrochemical detection method for HEDP was explored, utilizing the property of mercury complexation. Anodic sweep Differential Pulse Polarography gives an analytical signal for HEDP at +0.250 V vs Ag/AgCl

  6. Technetium 99m pertechnetate scans in congenital hypothyroidism

    International Nuclear Information System (INIS)

    Bauman, R.A.; Bode, H.H.; Hayek, A.; Crawford, J.D.

    1976-01-01

    Goiters are rarely palpable in infants with congenital hypothyroidism except in the case of maternal ingestion of iodide. The presence or absence of glandular tissue is, however, important for genetic and prognostic counseling and for acceleration of diagnosis in other affected siblings. The detection of thyroid tissue by /sup 99m/Tc pertechnetate scans in a significant number of our patients heretofore considered athyreotic establishes that physical findings and traditional laboratory data are not adequate to determine whether or not thyroid tissue is present

  7. Biosynthesis of (+)-cis- and (+)-trans-sabinene hydrate from geranyl pyrophosphate by a soluble enzyme system from sweet marjoram (Majorana hortensis)

    International Nuclear Information System (INIS)

    Hallahan, T.W.

    1988-01-01

    A soluble enzyme preparation from the leaves of sweet marjoram (Majorana hortensis Moench) catalyzes the divalent cation-dependent cyclization of [1- 3 H]geranyl pyrophosphate to the bicyclic monoterpene alcohols (+)-cis- and (+)-trans-[6 3 H]sabinene hydrate, providing labeling patterns consistent with current mechanistic considerations. The two enzymatic activities were inseparable by several chromatographic procedures, and differential inactivation studies suggesting that the two activities reside with the same enzyme. The enzymatic cyclization is considered to proceed by the initial ionization and isomerization of geranyl pyrophosphate to (-)-(3R)-linalyl pyrophosphate and the subsequent cyclization of this enzyme bound tertiary allylic intermediate to the monocyclic (+)-(4R)-α-terpinyl cation. A 1,2-hydride shift and a second cyclization with water capture of the resulting cation completes the reaction sequence. No free intermediates were detectable in the conversion of geranyl pyrophosphate to the sabinene hydrates as determined by isotopic dilution experiments

  8. Determination of technetium-99 from complex matrix

    International Nuclear Information System (INIS)

    Lixiong Wang; Lei Tang; Tongzai Yang; Yanqiu Yang; Liang Yang

    2013-01-01

    This paper reports an approach that can be used for efficient separation and determination of 99 Tc (as pertechnetate) after contamination of the environment by nuclear materials. The samples were decomposed by fusion in a mixture of potassium hydroxide and potassium nitrate. After fusion, technetium remains as the pertechnetate anion (TcO 4 - ). The technetium was isolated from the sample by technique combining solvent extraction, anion exchange, then, again, solvent extraction. After separation, 99 Tc was measured by isotope-dilution mass spectrometry with 97 Tc as spike. This method yielded nanogram detection limits for 99 Tc. (author)

  9. Patient exposure during thyroid scan in Khartoum Hospital

    International Nuclear Information System (INIS)

    Saeed, N. E. B.

    2013-03-01

    The aim of this study was to measure exposure during thyroid scan by using technetium-9 9m radioactive isotope. This study was conducted on 35 patients under thyroid scan, measured in Alnelein diagnostic center, data collected for the study included, age, sex, height, weight, and the material used in examination and the activity half-life of the material. The mean age was 41.83 years, while the mean body mass index (BMI) was 24.40, and the value of effective dose average 2.65±0.24 mSv. Data collected were analyzed by excel software and statistical analysis program, where the process of analysis category was given such as: age weight of patient, time of scan, the activity and the effective dose, it was found that thyroid scan was more common in female than male patients.(Author)

  10. β-pyrophosphate: A potential biomaterial for dental applications

    OpenAIRE

    Anastasiou, AD; Strafford, S; Posada-Estefan, O; Thomson, CL; Hussaein, SA; Edwards, TJ; Malinowski, M; Hondow, N; Metzger, NK; Brown, CTA; Routledge, MN; Brown, AP; Duggal, MS; Jha, A

    2017-01-01

    Tooth hypersensitivity is a growing problem affecting both the young and ageing population worldwide. Since an effective and permanent solution is not yet available, we propose a new methodology for the restoration of dental enamel using femtosecond lasers and novel calcium phosphate biomaterials. During this procedure the irradiated mineral transforms into a densified layer of acid resistant iron doped β-pyrophosphate, bonded with the surface of eroded enamel. Our aim therefore is to evaluat...

  11. Reduction And Sequestration Of Pertechnetate To Technetium Dioxide And Protection From Reoxidation

    International Nuclear Information System (INIS)

    Duncan, J. B.; Johnson, J. M.; Moore, R. C.; Hagerty, K.; Rhodes, R. N.; Huber, H. J.; Moore, W. P.

    2012-01-01

    This effort is part of the technetium management initiative and provides data for the handling and disposition of technetium. To that end, the objective of this effort was to challenge tin(lI)apatite (Sn(II)apatite) against double-shell tank 241-AN-105 simulant spiked with pertechnetate (TcO 4 ). The Sn(II)apatite used in this effort was synthesized on site using a recipe developed at and provided by Sandia National Laboratories; the synthesis provides a high quality product while requiring minimal laboratory effort. The Sn(ll)apatite reduces pertechnetate from the mobile +7 oxidation state to the non-mobile +4 oxidation state. It also sequesters the technetium and does not allow for re-oxidization to the mobile +7 state under acidic or oxygenated conditions within the tested period of time (6 weeks). Previous work indicated that the Sn(II) apatite can achieve an ANSI leachability index in Cast Stone of 12.8. The technetium distribution coefficient for Sn(lI)apatite exhibited a direct correlation with the pH of the technetium-spiked simulant media

  12. /sup 99m/Tc penicillamine: a renal cortical scanning agent

    International Nuclear Information System (INIS)

    Taylor, A.; Davis, G.; Halpern, S.; Ashburn, W.

    1977-01-01

    /sup 99m/Technetium penicillamine, a renal cortical imaging agent, can be used to provide a rapid, safe and non-invasive assessment of renal morphology and the renal vascular supply. Since this agent is not excreted significantly during the imaging procedure cortical scans of high quality can be obtained without image deterioration owing to a superimposed collecting system. These scans, which are clearly superior in anatomical detail to earlier scans using 131 I hippuran, can be obtained along with the 131 I hippuran renogram when the patient comes to the nuclear medicine department. Herein we demonstrate the anatomical detail it is now possible to achieve by presenting the cortical renal scans and accompanying radiograms from 5 patients with different renal pathology

  13. Geochemistry of natural technetium and plutonium

    International Nuclear Information System (INIS)

    Curtis, D.B.; Cappis, J.H.; Perrin, R.E.; Rokop, D.J.

    1987-01-01

    Technetium and plutonium in unprocessed nuclear reactor wastes are major concerns with regard to their containment in the geologic environment. Both nuclides have long half-lives; therefore, they will exist long after engineered barriers can be considered reliable. Consequently, strategies for the containment of these two elements depend on their retention in the geologic barrier until they have decayed to innocuous levels. Because these are the rarest elements in nature, there have been few direct observations of their geochemical behavior; predictions concerning their fate in the repository are based on properties that can be observed in the laboratory. The authors are attempting to complement the laboratory work by studying the geochemistry of natural plutonium and technetium. Ratios of anthropogenic to naturally occurring isotopes are discussed

  14. High pressure liquid chromatographic assay of technetium in solutions of sodium pertechnetate produced at the AAEC Research Establishment

    International Nuclear Information System (INIS)

    Farrington, K.J.

    1985-12-01

    High pressure liquid chromatography (HPLC) is used for the assay of nanogram quantities of technetium and to determine technetium in decayed pharmaceutical products, derived from three methods of manufacture. These methods of manufacture give comparably low levels of technetium-99, at the time of collection of the solution. However, when the solutions are used to produce ready-to-inject technetium-99m, high levels of technetium-99 are present at the time of calibration, which is the day after the collection date. Where sensitive reagent kits are to be labelled, freshly collected solutions of technetium-99m should be used. The HPLC assay is a valuable technique for the quality control of technetium-based radiopharmaceuticals, and for investigation of methods of manufacture of technetium-99m. Experimental studies confirmed the findings of previous workers

  15. Lymphoma imaging with a new technetium-99m labelled antibody, LL2

    International Nuclear Information System (INIS)

    Murthy, S.; Sharkey, R.M.; Goldenberg, D.M.; Lee, R.E.; Pinsky, C.M.; Hansen, H.J.; Burger, K.; Swayne, L.C.

    1992-01-01

    The lesion detection capability of a new technetium-99m labelled B-cell lymphoma monoclonal antibody (MoAb) imaging agent, LL2, was evaluated in 8 patients with non-Hodgkin's lymphoma and 1 patient with chronic lymphocytic leukaemia. The MoAb kit consists of a 1-vial, 1-mg Fab' form of LL2 ready for instant labelling with technetium. The patients were injected with ∝925 MBq (25 mCi) of 99m Tc-LL2 Fab' (1 mg), and planar and single photon emission tomography (SPET) studies were performed at 3-4 h post injection and at 24 h. There was no evidence of thyroid or stomach activity up to 24 h. Uniform splenic uptake was seen in all patients. Two non-lymphoma patients were also administered with the same agent and demonstrated a similar splenic distribution; therefore, splenic targeting was not scored as tumour-specific. A total of 29 from 48 tumour sites were detected by scintigraphy, including tumours of various grades and histological types. Excluding 1 patient who had a large tumour burden of over 500 g, 29 of 33 lesions were detected. One patient was free of disease at the time of the study and had a negative scan. Another patient showed excellent targeting of gallium-negative sites in the liver and bone. The bone involvement was not known prior to the antibody study and was subsequently confirmed by a bone scan. Additional sites of MoAb localization could not be followed in this group, since most patients went on to radioimmunotherapy immediately following the 99m Tc-LL2 study. However, these initial results suggest that this new 99m Tc-labelled antibody imaging kit should be further investigated for its potential role in the staging and follow-up of lymphoma patients. (orig.)

  16. Determination of a method to inhibit technetium migration at the repository

    International Nuclear Information System (INIS)

    Statler, V.; Tulenko, J.; Cloke, P.

    1990-01-01

    The long-term migration of 99 Tc (213,000-yr half-life) must be considered when examining the disposal of spent nuclear fuel in a geologic repository. This report outlines an investigation of the effects of iron, tin, stannous chloride, copper, manganese, and vanadium as reactants added to a mixture of technetium and J-13 well water to cause technetium precipitation. The J-13 well water was chosen because it is representative of the groundwater located at Yucca Mountain. A state-of-the-art computer software package, EQ3/6, was developed at Lawrence Livermore National Laboratory and was utilized in this study to project the result when metallic iron, tin, copper, manganese, and vanadium and the compound stannous chloride are individually added to a mixture of metallic technetium and J-13 well water. The computer codes in this study indicate that the problems associated with technetium migration at the federal repository are not insurmountable if a reactant capable of producing reducing conditions to the incoming groundwater is integrated into the waste package. Further work will focus on the laboratory experimentation to validate the computer results and to determine the best materials and configurations to inhibit technetium migration at the repository

  17. Jointscintigraphy with 99m Tc-pyrophosphate

    International Nuclear Information System (INIS)

    Mirtl, B.; Leb, G.; Klein, G.; Goebel, R.; Eber, O.

    1975-01-01

    Joint scintigraphy was performed in 85 patients suffering from a variety of rheumatic diseases, using a gamma camera and line scanner. Tc-pyrophosphate was the radio nuclide employed; it accumulates selectively in the juxta-articular parts of the bone. The method provides an objective demonstration of inflammatory and degenerative rheumatic joint changes. More over scintigraphic changes can be demonstrated in joint disease which is too early to be clinically apparent or before there are any corresponding changes in serological parameters. The method is useful both in the localisation and staging of disease, in the evaluation of treatment and as an objective control of clinical skills. (orig.) [de

  18. The Evaluation of Novel Tin Materials for the Removal of Technetium from Groundwater

    Energy Technology Data Exchange (ETDEWEB)

    Parker, Kent E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wellman, Dawn M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-06-30

    Technetium-99 (99Tc) is present at several U.S. Department of Energy (DOE) facilities, including the Hanford, Oak Ridge, Paducah, Portsmouth, and Savannah River sites. Due to its mobility, persistence, and toxicity in the environment, developing means to immobilize and/or remove technetium from the environment is currently a top priority for DOE. However, there are currently very few approaches that effectively manage the risks of technetium to human health and the environment. The objective of this study is to evaluate novel synthetic materials that could enable direct removal of technetium from groundwater. The following report •assesses the viability of existing methodologies for synthesis of tin (II) apatite for in situ formation and remediation of 99Tc within the subsurface environment •discusses the development of alternative methodologies for production of tin (II) apatite •evaluates nanoporous tin phosphate materials for removal of technetium from groundwater.

  19. Method for recovering palladium and technetium values from nuclear fuel reprocessing waste solutions

    Science.gov (United States)

    Horwitz, E. Philip; Delphin, Walter H.

    1979-07-24

    A method for recovering palladium and technetium values from nuclear fuel reprocessing waste solutions containing these and other values by contacting the waste solution with an extractant of tricaprylmethylammonium nitrate in an inert hydrocarbon diluent which extracts the palladium and technetium values from the waste solution. The palladium and technetium values are recovered from the extractant and from any other coextracted values with a strong nitric acid strip solution.

  20. Ligand-free, protein-bound technetium-99m. Evidence for tumour localisation

    International Nuclear Information System (INIS)

    Jakovljevic, A.C.; Pojer, P.M.

    1984-11-01

    An hypothesis that cations accumulate in tumours independent of ligand is tested. A preparation of technetium-99m known to be ligand-free (that is, the technetium is protein bound and no other ligand is injected) has been shown to accumulate in a T-cell lymphoma

  1. Importance of scintigraphy of the myocardium with Csup(99m)-Tc-pyrophosphate in the diagnosis of myocardial ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Botnar' , V I; Dvoskina, I S [Inst. Kardiologii Vsesoyuznogo Kardiologicheskogo Nauchnogo Tsentra AN SSSR

    1983-10-01

    The following aspects of the method of scintigraphy of the myocardium with sup(99m)Tc-pyrophosphate as test sensitivity, possibility of estimating necrosis focus, prognostic importance of the method, scintigram dynamics in case of acute infarction, pyrophosphate accumulation in myocardial cells are considered. Advantages and prospects of the method for visualization of acute myocardium infarction focus and in cases of other pathological states are pointed out.

  2. Non-invasive investigation of the upper gastrointestinal tract using technetium - 99m

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, T V [Royal Infirmary, Edinburgh (UK)

    1979-01-01

    The use of technetium - 99m in the non-invasive investigation of the upper gastrointestinal tract is discussed with particular reference to the evolution of a method of assessing gastric function or gastric acid secretion non-invasively and to the applications of this method in the investigation of surgical patients with disease of the upper gastrointestinal tract. The assessment of maximal acid output and the insulin response is described and the use of the test in the diagnosis of pernicious anaemia, hypo- and hyperchlorhydric states, gastric cancer, hiatus hernia and Barrett's oesophagus, coeliac disease, Meckel's diverticulum, and abdominal aortic aneurism outlined. The use of chemicals labelled with this tracer in hepatobilary scanning is briefly described.

  3. Quality control for a group of pyrophosphate-Sn kits

    International Nuclear Information System (INIS)

    Isaac, M.; Gamboa, R.; Hernandez, I.; Leyva, R.; Turino, D.

    1994-01-01

    The quality control for a group of Pyrophosphate-Sn kits for labeling with 99 m Tc is carry out at the Isotope Center. A general discussion takes place about the instrumental techniques for the determination of the kit constituent such as ligands, Sn(II), water, etc, as well as the control table for the evaluation of the warranty time. (author). 5 refs, 4 figs

  4. Hyaline cartilage involvement in patients with gout and calcium pyrophosphate deposition disease. An ultrasound study.

    Science.gov (United States)

    Filippucci, E; Riveros, M Gutierrez; Georgescu, D; Salaffi, F; Grassi, W

    2009-02-01

    The main aim of the present study was to determine the sensitivity, specificity and accuracy of ultrasonography (US) in detecting monosodium urate and calcium pyrophosphate dihydrate crystals deposits at knee cartilage level using clinical definite diagnosis as standard reference. A total of 32 patients with a diagnosis of gout and 48 patients with pyrophosphate arthropathy were included in the study. Fifty-two patients with rheumatoid arthritis (RA), psoriatic arthritis or osteoarthritis (OA) were recruited as disease controls. All diagnoses were made using an international clinical criterion. US examinations were performed by an experienced sonographer, blind to clinical and laboratory data. Hyaline cartilage was assessed to detect two US findings recently indicated as indicative of crystal deposits: hyperechoic enhancement of the superficial margin of the hyaline cartilage and hyperechoic spots within the cartilage layer not generating a posterior acoustic shadow. Hyperechoic enhancement of the chondrosynovial margin was found in at least one knee of 14 out of 32 (43.7%) patients with gout and in a single knee of only one patient affected by pyrophosphate arthropathy (specificity=99%). Intra-cartilaginous hyperechoic spots were detected in at least one knee of 33 out of 48 (68.7%) patients with pyrophosphate arthropathy and in two disease controls one with OA and the second with RA (specificity=97.6%). The results of the present study indicate that US may play a relevant role in distinguishing cartilage involvement in patients with crystal-related arthropathy. The selected US findings were found to be highly specific.

  5. Relationship between bone uptake of /sup 99m/Tc-pyrophosphate and hydroxyproline in blood and urine

    International Nuclear Information System (INIS)

    Wiegmann, T.; Kirsh, J.; Rosenthall, L.; Kaye, M.

    1976-01-01

    In a group of hospital patients with various diseases, the urinary hydroxyproline-to-creatinine ratio showed a significant correlation (r = 0.63; p is less than 0.001) with the 5-hr bone-to-soft-tissue ratio for /sup 99m/Tc-pyrophosphate uptake. In patients on chronic hemodialysis, a similar correlation was found between the 5-hr bone-to-soft-tissue ratio and hydroxyproline levels in plasma and serum. The findings suggest that /sup 99m/Tc-pyrophosphate binding by bone is related to collagen metabolism

  6. ASSESSMENT OF TECHNETIUM LEACHABILITY IN CEMENT-STABILIZED BASIN 43 GROUNDWATER BRINE

    International Nuclear Information System (INIS)

    Duncan, J.B.; Cooke, G.A.; Lockrem, L.L.

    2009-01-01

    This report documents the effort to sequester technetium by the use of getters, reductants (tin(II) apatite and ferrous sulfate), sorbents (A530E and A532E ion exchange resins), and cementitious waste form. The pertechnetate form of technetium is highly soluble and mobile in aerobic (oxidizing) environments.

  7. Inositol pyrophosphates promote tumor growth and metastasis by antagonizing liver kinase B1

    Science.gov (United States)

    Rao, Feng; Xu, Jing; Fu, Chenglai; Cha, Jiyoung Y.; Gadalla, Moataz M.; Xu, Risheng; Barrow, James C.; Snyder, Solomon H.

    2015-01-01

    The inositol pyrophosphates, molecular messengers containing an energetic pyrophosphate bond, impact a wide range of biologic processes. They are generated primarily by a family of three inositol hexakisphosphate kinases (IP6Ks), the principal product of which is diphosphoinositol pentakisphosphate (IP7). We report that IP6K2, via IP7 synthesis, is a major mediator of cancer cell migration and tumor metastasis in cell culture and in intact mice. IP6K2 acts by enhancing cell-matrix adhesion and decreasing cell–cell adhesion. This action is mediated by IP7-elicited nuclear sequestration and inactivation of the tumor suppressor liver kinase B1 (LKB1). Accordingly, inhibitors of IP6K2 offer promise in cancer therapy. PMID:25617365

  8. Technetium behaviour in Boom Clay - a laboratory and field study

    International Nuclear Information System (INIS)

    Baston, G.M.N.; Ilett, D.J.; Cowper, M.M.; Pilkington, N.J.; Tweed, C.J.; Williams, S.J.; Canniere, P.R. de; Wang, L.

    2002-01-01

    This paper describes a study of technetium solubility and migration under chemical conditions representative of those prevailing in a Boom Clay environment. Laboratory and in situ measurements yielded similar aqueous concentrations of technetium, of about 1 x 10 -8 mol dm -3 , close to the concentrations measured for hydrated technetium(IV) oxide TcO 2 .1.6H 2 O in the solubility studies. From fitting the curves of the Tc concentrations as function of time, distribution coefficient (K d ) values were estimated to lie between 0.8 cm 3 g -1 and 1.8 cm 3 g -1 . Exposure of the system at 80 C and to γ-radiation dose rates of several hundred Gy h -1 resulted in only minor differences in behaviour. (orig.)

  9. Use of myocardial imaging in the evaluation of patients with cardiovascular disease

    Energy Technology Data Exchange (ETDEWEB)

    Pitt, B.; Strauss, H.W.; Trhall, J.H.

    1980-01-01

    The role of radioisotope tracer techniques in the evaluation of patients with congenital heart disease, valvular heart disease, suspected myocardial infarction, ischemia or suspected ventricular dysfunction is reviewed. Thallium-201 myocardial imaging and exercise blood pool imaging and Technetium-88m pyrophosphate imaging of myocardial infarction are most commonly used.

  10. Oscillator strengths for neutral technetium

    International Nuclear Information System (INIS)

    Garstang, R.H.

    1981-01-01

    Oscillator strengths have been calculated for most of the spectral lines of TcI which are of interest in the study of stars of spectral type S. Oscillator strengths have been computed for the corresponding transitions in MnI as a partial check of the technetium calculations

  11. Thermal neutron cross section measurements for technetium-99

    International Nuclear Information System (INIS)

    Yates, M.A.; Schroeder, N.C.; Fowler, M.M.

    1993-01-01

    Technetium, because of its long half-like (213,000 years) and ability to migrate in the environment, is a primary contributor to the long-term radioactivity related risk associated with geologic nuclear waste disposal. One proposal for converting technetium to an environmentally benign element investigating transmutation with an accelerator-based system, (i.e., Accelerator Transmutation of Waste, ATW). Planning for efficient processing of technetium through the transmuter will require knowledge of the thermal neutron cross section for the 99 Tc (n,γ) 100 Tc reaction. The authors have recently remeasured this cross section. Weighed aliquots (19-205 μg) of a NIST traceable 99 Tc standard were irradiated for 30-150 sec using the pneumatic open-quotes rabbitclose quotes system of LANL's Omega West Reactor. The two gamma rays from the 15.7-sec half-life product were measured immediately after irradiation on a high-resolution Ge detector. Thermal fluxes were measured using gold foils and Cd wrapped gold foils. The observation cross section is 19 ± 1 b. This agrees well with the 1977 value but has half the uncertainty

  12. Effect of acidity and chemical composition of sup(99m)Tc-radiopharmaceuticals on sup(99m)Tc accumulation in necrotic tissue of rat myocardium

    Energy Technology Data Exchange (ETDEWEB)

    Vilcek, S; Machan, V; Kalincak, M [Ustav Radioekologie a Vyuzitia Jadrovej Techniky, Kosice (Czechoslovakia); Nicak, A [Univerzita P.J. Safarika, Kosice (Czechoslovakia). Lekarska Fakulta

    1981-04-30

    Experiments showed that the cumulation of technetium-99m following the administration of /sup 99m/Tc-Sn-pyrophosphate and s/sup 99m/Tc-Sn-oxytetracycline in the necrotic tissue of rat myocardium damaged by cauterization depended on the end pH value. The maximum /sup 99m/Tc cumulation in the myocardial lesion was noted when the end pH value ranged in 5.5 to 6.0. It appeared that pyrophosphate concentration decrease below the critical limit not only affected the cumulation of /sup 99m/Tc in the particular organs but also in the necrotic tissue of the myocardium.

  13. Effect of acidity and chemical composition of sup(99m)Tc-radiopharmaceuticals on sup(99m)Tc accumulation in necrotic tissue of rat myocardium

    International Nuclear Information System (INIS)

    Vilcek, S.; Machan, V.; Kalincak, M.; Nicak, A.

    1981-01-01

    Experiments showed that the cumulation of technetium-99m following the administration of sup(99m)Tc-Sn-pyrophosphate and sup(99m)Tc-Sn-oxytetracycline in the necrotic tissue of rat myocardium damaged by cauterization depended on the end pH value. The maximum sup(99m)Tc cumulation in the myocardial lesion was noted when the end pH value ranged in 5.5 to 6.0. It appeared that pyrophosphate concentration decrease below the critical limit not only affected the cumulation of sup(99m)Tc in the particular organs but also in the necrotic tissue of the myocardium. (author)

  14. Potent inhibition of mammalian ribonucleases by 3', 5'-pyrophosphate-linked nucleotides.

    Science.gov (United States)

    Russo, N; Shapiro, R

    1999-05-21

    Molecular modeling based on the crystal structure of the complex of bovine pancreatic RNase A with the inhibitor 5'-diphosphoadenosine 3'-phosphate (ppAp) (Leonidas, D. D., Shapiro, R., Irons, L. I., Russo, N., and Acharya, K. R. (1997) Biochemistry 36, 5578-5588) was used to design new inhibitors that extend into unoccupied regions of the enzyme active site. These compounds are dinucleotides that contain an unusual 3',5'-pyrophosphate linkage and were synthesized in solution by a combined chemical and enzymatic procedure. The most potent of them, 5'-phospho-2'-deoxyuridine 3'-pyrophosphate, P' --> 5'-ester with adenosine 3'-phosphate (pdUppAp), binds to RNase A with Ki values of 27 and 220 nM at pH 5.9 and 7, respectively. These values are 6-9-fold lower than those for ppAp and 50-fold lower than that for the transition state analogue, uridine vanadate. pdUppAp has broad specificity; it is an effective inhibitor of at least two other members of the pancreatic RNase superfamily, human RNase-2 (eosinophil-derived neurotoxin) and RNase-4, which share only 36-44% sequence identity with the pancreatic enzyme. The potency of pdUppAp and the other inhibitors described here depends critically on the extended internucleotide linkage; the pyrophosphate group enhances dinucleotide binding to the three RNases by 2.1-2.9 orders of magnitude, as compared with a monophosphate. These data give further insight into the organization of the catalytic centers of the various RNases. Moreover, the new class of inhibitors provides a useful means by which to probe the biological actions of these and other related enzymes.

  15. Determination of technetium by graphite furnace atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Kaye, J.H.; Ballou, N.E.

    1978-01-01

    A detection limit of 6 x 10 -11 g has been achieved for measurement of technetium by graphite furnace atomic absorption spectrometry. A commercially available, demountable, hollow cathode lamp was used and both argon and neon were used as fill gases for the lamp. The range of applicability of the method, when the unresolved 2614.23 to 2615.87 A doublet is used for analysis, is from 60 pg to at least 3 ng of technetium per aliquot analyzed. 3 figures, 1 table

  16. Study of ammonia synthesis using technetium catalysts

    International Nuclear Information System (INIS)

    Spitsyn, V.I.; Mikhajlenko, I.E.; Pokrovskaya, O.V.

    1982-01-01

    A study was made on catalytic properties of technetium in ammonia synthesis reaction. The preparation of technetium catalysts on ν-Al 2 O 3 , BaTiO 3 , BaO-ν-Al 2 O 3 substrates is described. The investigation of catalytic activity of catalysts was carried out at a pressure of 1 atm. in vertical reactor with volume rate of 15000 h - 1 in the temperature range of 350-425 deg. The amount of catalyst was 0.5-1 g, the volume- 0.5 ml, the size of granules- 2-3 mm. Rate constants of ammonia synthesis reaction were calculated. Seeming activation energies of the process have meanings wihtin the limits of 40-50 kcal/mol. It was shown that with increase in concentration of Tc on BaTiO 3 the catalytic activity rises in comparison with pure Tc. The reduction of catalytic activity with increase of metal content on Al 2 O 3 begins in the limits of 3.5-6.7% Tc/ν-Al 2 O 3 . The catalyst of 5.3% Tc/4.1% Ba/ν -Al 2 O 3 compound has the maximum activity. Technetium catalysts possess the stable catalytic activity and don't requre its reduction during several months

  17. Gentc99m, computational system for the technetium-99m generator

    International Nuclear Information System (INIS)

    Suparman, I.

    1997-01-01

    The technetium-99m generator is one of the main products of the PPR, as the continuity of the technetium-99m generator production is important for supporting the development of nuclear medicine. GENTC99M has been made for computational for the technetium-99m generator and includes data processing, documentation and information GENTC99M is also very useful in quality control application especially for the determinations of yield and radionuclidic impurities which consume much time. microsoft visual basic for MS-DOS and visual basic for windows have been used for making GENTC99M. Microsoft visual basic has several features that make it an ideal development language for both MS-DOS and Microsoft Windows. These features not only increase productivity, they also provide all the tools and hooks needed to develop some very sophisticated applications. for a production centre like PPR, GENTC99M is very useful to support the data processing, documentation and information system of the technetium-99m generator and it can also be modified for other products

  18. Speciation and Oxidative Stability of Alkaline Soluble, Non-Pertechnetate Technetium

    Energy Technology Data Exchange (ETDEWEB)

    Levitskaia, Tatiana G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rapko, Brian M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Anderson, Amity [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Peterson, James M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chatterjee, Sayandev [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Walter, Eric D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Cho, Herman M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Washton, Nancy M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-09-30

    The long half-life, complex chemical behavior in tank waste, limited incorporation in mid- to high-temperature immobilization processes, and high mobility in subsurface environments make technetium (Tc) one of the most difficult contaminants to dispose of and/or remediate. Technetium exists predominantly in the liquid tank waste phase as the relatively mobile form of pertechnetate, TcO4-. However, based on experimentation to date a significant fraction of the soluble Tc cannot be effectively separated from the wastes and may be present as a non- pertechnetate species. The presence of a non-pertechnetate species significantly complicates disposition of low-activity waste (LAW), and the development of methods to either convert them to pertechnetate or to separate directly is needed. The challenge is the uncertainty regarding the chemical form of the alkaline-soluble low-valent non-pertechnetate species in the liquid tank waste. This report summarizes work done in fiscal year (FY) 2014 exploring the chemistry of a low-valence technetium(I) species, [(CO)3Tc(H2O)3]+, a compound of interest due to its implication in the speciation of alkaline-soluble technetium in several Hanford tank waste supernatants.

  19. Technetium behaviour in Boom Clay - a laboratory and field study

    Energy Technology Data Exchange (ETDEWEB)

    Baston, G.M.N.; Ilett, D.J.; Cowper, M.M.; Pilkington, N.J.; Tweed, C.J.; Williams, S.J. [AEA Technology plc, Harwell, Didcot, Oxfordshire (United Kingdom); Canniere, P.R. de; Wang, L. [SCK.CEN, Waste and Disposal Project, Boeretang, Mol (Belgium)

    2002-07-01

    This paper describes a study of technetium solubility and migration under chemical conditions representative of those prevailing in a Boom Clay environment. Laboratory and in situ measurements yielded similar aqueous concentrations of technetium, of about 1 x 10{sup -8} mol dm{sup -3}, close to the concentrations measured for hydrated technetium(IV) oxide TcO{sub 2}.1.6H{sub 2}O in the solubility studies. From fitting the curves of the Tc concentrations as function of time, distribution coefficient (K{sub d}) values were estimated to lie between 0.8 cm{sup 3} g{sup -1} and 1.8 cm{sup 3} g{sup -1}. Exposure of the system at 80 C and to {gamma}-radiation dose rates of several hundred Gy h{sup -1} resulted in only minor differences in behaviour. (orig.)

  20. Technetium-99m DTPA aerosol and gallium scanning in acquired immune deficiency syndrome

    International Nuclear Information System (INIS)

    Picard, C.; Meignan, M.; Rosso, J.; Cinotti, L.; Mayaud, C.; Revuz, J.

    1987-01-01

    In 11 non-smoking AIDS patients suspected of pneumocystis carinii pneumonia (PCP), the results of Tc-99m DTPA aerosol clearances, gallium scans, and arterial blood gases were compared with those of bronchoalveolar lavage (BAL). Nine patients had PCP. All had increased clearances five times higher than the normal (5.6 +/- 2.3% X min-1 vs 1.1 +/- 0.34% X min-1, N = 10, P less than 0.001), suggesting an increased alveolar permeability. Gallium scans were abnormal in six patients but normal or slightly abnormal in the three others. Four of these nine patients had normal chest x-rays. In two of these the gallium scan was abnormal, but in the two others, only the increased Tc-99m DTPA clearances showed evidence of lung disease. Two patients had normal BAL, with normal clearances and gallium scans. Four out of the nine patients with PCP were studied after treatment. Three recovered and had normal clearance and gallium scans. One still had PCP with increased clearance but normal gallium scan. Gallium scanning and Tc-99m DTPA clearance are useful for detecting lung disease in AIDS patients with suspected PCP and for prompting BAL when chest x-rays and PaO 2 levels are normal. Due to its high sensitivity, a normal Tc-99m DTPA clearance could avoid BAL

  1. Sorption of technetium and its analogue rhenium on bentonite material under aerobic conditions

    International Nuclear Information System (INIS)

    Vinsova, H.; Koudelkova, M.; Konirova, R.; Vecernik, P.; Jedinakova-Krizova, V.

    2003-01-01

    The uptake of technetium on bentonite materials has been studied from the point of view of characterization of long-term radioactive elements behavior in nuclear waste repository. Bentonite R (locality Rokle, Czech Republic) and two types of model groundwater (granitic and bentonite) were selected for the sorption experiments. It is generally known that bentonite materials show an excellent cation-exchange capacity and, on the other hand, a poor uptake of anions. Technetium occurs under aerobic conditions in its most stable oxidation state (+VII) as pertechnetate, which makes a question of its sorption on bentonite more complex when compared with e.g. Cs + or Sr 2+ . To increase the K d values for technetium sorption on bentonite, it is necessary to carry out the experiments under anaerobic conditions in the presence of reducing agent, which is capable to lower the oxidation state of technetium which enables its successful immobilization. The aim of our research has been to find out the conditions suitable for the technetium sorption on selected bentonite under oxidizing conditions. The sorption experiments with Tc-99 on bentonite have been carried out by batch method. The influence of the addition of different materials (e.g. activated carbon, graphite, Fe 2+ , Fe) with bentonite, the effect of solid:aqueous phase ratio and a pH value on the percentage of technetium uptake and on the K d values were tested. Perrhenate was selected as an analogue of pertechnetate in non-active experiments of capillary electrophoresis (CE) and isotachophoresis (ITP). The percentage of rhenium sorbed on bentonite material was determined from the decrease of perrhenate peak area (CE) and from the shortening of the ITP zone corresponding to perrhenate. Both electromigration methods provided comparable results. The results obtained in this study with non-active material were compared to those of technetium acquired by radiometry and polarography. (authors)

  2. Study of reduction and complexation of technetium in the presence of humate

    International Nuclear Information System (INIS)

    Tkac, P.

    2003-06-01

    Reduction of pertechnetate was studied by different reduction systems: Sn 2+ , Fe 2+ , ascorbic acid, mixture of ascorbic acid and Fe 3+ , and thiourea. Reduction of pertechnetate by Sn 2+ ions (5 · 10 -2 - 5 · 10 -7 mol.dm -3 ) was studied in pH range of 0.94-6.4. For effective reduction of Tc(VII) an acidic environment (pH 2+ ions higher than 1 · 10 -5 mol.dm-3 was necessary. Reduction of Tc(VII) by Fe 2+ (0.01 mol.dm -3 FeSO 4 ) was strongly dependent on pH and for reduction yield higher than 95 %, pH = 8 and higher was needed. In the presence of ascorbic acid (1 - 5 %) no significant reduction was observed. When a 5 % solution of ascorbic acid was prepared by dilution of ascorbic acid in 2 mol.dm -3 HCl, 60 % reduction after 30 minutes of reaction was observed. Reduction of Tc(VII) in the presence of ascorbic acid was most effectively observed in the presence of Fe 3+ ions. The yield of reduction was about 98 % after 20 minutes of reaction. Reduction of pertechnetate by thiourea was studied in acidic solution (HCl). Different conditions were used for reduction of 99m TcO 4 - and 99 TcO 4 - , respectively. The best yield for a routine preparation of [ 99 Tc(tu) 6 ] 3+ (tu = thiourea) was observed when 70 mg of thiourea was dissolved in 5 ml of 0.5 mol.dm -3 HCl and 0.2 - 0.5 ml of 6 · 10 -2 mol.dm -3 TcO 4 - was added. The mixture was allowed to react at least 20 hours. In the case of 99m Tc, 35 mg of thiourea was diluted in 5 ml of 2 mol.dm -3 HCl and 0.1 - 0.5 ml of pertechnetate generator solution was added. Reaction mixture was heated at 100 grad C for at least 30 minutes under nitrogen atmosphere. The yield of pertechnetate reduction for both preparation methods was about 99 %. The thiourea complex of technetium was chosen for preparation of technetium-humic complex, because it is well known as the most suitable precursor for preparation of new technetium complexes with Tc 3+ . Gel chromatography of natrium humate was carried out before preparation of

  3. Coordination chemistry of technetium as related to nuclear medicine

    International Nuclear Information System (INIS)

    Srivastava, S.C.; Richards, P.

    1982-01-01

    Significant advances have been made in the area of technetium coordination chemistry during the last five years. The main driving force behind this recent surge of interest in the field has been due to the practical application of technetium-99m in the rapidly growing speciality of nuclear medicine. Technetium-99 is one of the products of nuclear fission reactions, but it was the development of the molybdenum-99-technetium-99m generator about two decades ago that provided the basis for the development of radiopharmaceuticals routinely used in modern diagnostic applications. The chemistry of this element has proven to be quite rich owing to its multiple oxidation states and variable geometry. This can be attributed to its position in the middle of the periodic table. Diagnostic radiopharmaceuticals comprise predominantly III, IV and V oxidation states of Tc and involve a variety of coordination complexes. Even though the chemistry of Tc has been slow to evolve, recent synthetic advances have provided a more scientific basis for the study of a number of compounds with diverse coordination geometries and structures. Ligands with oxygen, nitrogen and sulfur donor atoms have been utilized to elucidate various aspects of the coordination chemistry of Tc. Single crystal X-ray structural analysis has been extensively used to characterize Tc complexes and thus construct a firm foundation for the study of synthetic and mechanistic aspects of the chemistry of this element. (author)

  4. Bone scanning with technetium /sup 99m/Tc polyphosphate in tuberculous osteomyelitis

    Energy Technology Data Exchange (ETDEWEB)

    Fanning, A; Dierich, H; Lentle, B

    1974-09-01

    Bone scans in 7 patients with tuberculosis have indicated bony involvement in 3. This was unsuspected in 2 and in all 3 radiographic correlation has been obtained. The present ready availability of more modern bone scanning agents and their safety is important to remember. They provide an elegant and sensitive, if non-specific, index of bone disease.

  5. Behavior of technetium in nuclear waste vitrification processes.

    Science.gov (United States)

    Pegg, Ian L

    Nearly 100 tests were performed with prototypical melters and off-gas system components to investigate the extents to which technetium is incorporated into the glass melt, partitioned to the off-gas stream, and captured by the off-gas treatment system components during waste vitrification. The tests employed several simulants, spiked with 99m Tc and Re (a potential surrogate), of the low activity waste separated from nuclear wastes in storage in the Hanford tanks, which is planned for immobilization in borosilicate glass. Single-pass technetium retention averaged about 35 % and increased significantly with recycle of the off-gas treatment fluids. The fraction escaping the recycle loop was very small.

  6. Analysis of Technetium Species and Fractions in Natural Seaweed Using Biochemical Separation and ICP-MS Measurement

    DEFF Research Database (Denmark)

    Shi, Keliang; Hou, Xiaolin; Qiao, Jixin

    2016-01-01

    An extremely high accumulation and retention of technetium in marine plants, especially brown seaweed, makes it a unique bioindicator of technetium. In the present work, a novel approach was developed for the speciation analysis of technetium in seaweed, wherein a series of biochemical separations....... Besides the inorganic species of TcO4-, most of technetium (>75%) combined with organic components of seaweed such as algin, cellulose, and pigment. This investigation could provide important fundamental knowledge for studying the processes and mechanisms of 99Tc accumulation in the natural seaweed....

  7. Simultaneous thallium-201/technetium-99m pyrophosphate tomography in patients with acute myocardial infarction: comparison of rotational SPECT and seven pinhole tomography

    International Nuclear Information System (INIS)

    Krause, T.; Schuemichen, C.; Beck, A.; Moser, E.; Zeiher, A.

    1992-01-01

    Simultaneous Tl-201/Tc-99m pyrophosphate (PPi) tomography was compared to Tc-99m PPi tomography and rotational SPECT (SPECT) was compared to seven pinhole tomography (9-PHT), respectively, in 19 patients with acute myocardial infarction (AMI). The results were correlated to electrocardiographic and angiographic findings. With Tl-201/Tc-99, PPi, all infarctions were detected and site of infarction was determined, independent of the tomographic technique used. There was no significant difference between the two acquisition techniques 7-PHT and SPECT concerning spatial extent of Tc-99m PPi accumulation and the uptake ratio. However, using only Tc-99m PPi without Tl-201 as anatomical marker, SPECT detected 15/19 infarctions. In 7 of these 15 cases infarction site was correctly determined. 7-PHT detected 11/19 and site was correctly determined in 9/11 infarctions. Myocardial infarctions which failed diagnosis using Tc-99m PPi alone showed significantly smaller spatial extent of Tc-99m PPi accumulation and necrosis to blood pool ratio was lower as assessed by Tl201/Tc-99m PPi tomography. In conclusions, tomography using simultaneous Tl-201/Tc-99m PPi imaging is a reliable technique for diagnosis and localization of AMI. For this reason, results obtained with SPECT and 7-PHT are comparable. Independent of the tomographic technique used, combined imaging is superior to Tc-99m PPi alone without Tl-201 as additional anatomical marker (orig./MG) [de

  8. Stabilization through precipitation in a system of colloidal iron(III) pyrophosphate salts

    NARCIS (Netherlands)

    van Leeuwen, Y.M.; Velikov, K.P.; Kegel, W.K.

    2012-01-01

    The ionic strength of a solution decreases during the precipitation of an insoluble salt, which can cause an initially unstable colloidal system to stabilize during its formation. We show this effect in the precipitation and aging of colloidal iron(III) pyrophosphate, where we observe two distinct

  9. Technetium-99 m generator safety simulation

    International Nuclear Information System (INIS)

    Kang, Sang Koo; Kim, Chong Yeal

    2008-01-01

    Technetium ( 99m Tc) is one of the most widely used radioactive isotopes for diagnosis in the world. In general, 99m Tc is produced inside the so called technetium generator where 99Mo decays to 99m Tc. And the generator is usually made out of lead to shield relatively high energy radiation from 99m Tc and 99 Mo. In this paper, a GEANT4 simulation is carried out to test the safety of the 99m Tc generators, taking domestic and Japanese products with radioactivity of 18.50 GBq (500 mCi) for example. According to the domestic regulation on radiation safety, the dose at 10 cm and 100 cm away from the surface of radiation shielder should not exceed 2 mSv∙h -1 and 0.02 mSv∙h -1 , respectively. The simulated dose turned out about only 10% of the limit, satisfying the domestic regulation

  10. Non-Pertechnetate Technetium Sensor Research and Development

    Energy Technology Data Exchange (ETDEWEB)

    Bryan, Samuel A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Crawford, Amanda D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Heineman, William R. [Univ. of Cincinnati, OH (United States); Rapko, Brian M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Branch, Shirmir D. [Univ. of Cincinnati, OH (United States)

    2014-09-01

    There remain several significant uncertainties in the understanding and modeling of the fate and speciation of 99Tc in Hanford waste tanks, glass, and low-temperature waste forms. A significant (2% to 25%) fraction of the 99Tc in the water-soluble portion of the tank waste may be present as a non-pertechnetate species that has not been identified and, based on experimentation to date, cannot be effectively separated from the wastes. This task will provide a sensor specifically tuned to detect the Tc(I)-carbonyl species believed to constitute the main fraction of the non-pertechnetate form of technetium. By direct measurement of the non-pertechnetate species, such a sensor will help reduce the uncertainties in the modeling of the fate and speciation of 99Tc in Hanford tanks and waste forms. This report summarizes work done in FY 2014 exploring the chemistry of a low-valence technetium species, [Tc(CO)3(H2O)3]+, a compound of interest due to its implication in the speciation of alkaline-soluble technetium in several Hanford tank waste supernatants. Progress made in FY 2014 was sponsored by the Department of Energy’s Office of Environmental Management and is summarized in this report.

  11. Three-dimensional structure of phosphoribosyl pyrophosphate synthetase from E. coli at 2.71 Å resolution

    Energy Technology Data Exchange (ETDEWEB)

    Timofeev, V. I., E-mail: inna@ns.crys.ras.ru, E-mail: tostars@mail.ru, E-mail: ugama@yandex.ru [Russian Academy of Sciences, Shubnikov Institute of Crystallography (Russian Federation); Abramchik, Yu. A. [Russian Academy of Sciences, Shemyakin–Ovchinnikov Institute of Bioorganic Chemistry (Russian Federation); Zhukhlistova, N. E. [Russian Academy of Sciences, Shubnikov Institute of Crystallography (Russian Federation); Muravieva, T. I.; Esipov, R. S. [Russian Academy of Sciences, Shemyakin–Ovchinnikov Institute of Bioorganic Chemistry (Russian Federation); Kuranova, I. P. [Russian Academy of Sciences, Shubnikov Institute of Crystallography (Russian Federation)

    2016-01-15

    Phosphoribosyl pyrophosphate synthetase from Escherichia coli was cloned, purified, and crystallized. Single crystals of the enzyme were grown under microgravity. The X-ray diffraction data set was collected at the Spring-8 synchrotron facility and used to determine the three-dimensional structure of the enzyme by the molecular-replacement method at 2.71 Å resolution. The active and regulatory sites in the molecule of E. coli phosphoribosyl pyrophosphate synthetase were revealed by comparison with the homologous protein from Bacillus subtilis, the structure of which was determined in a complex with functional ligands. The conformations of polypeptide-chain fragments surrounding and composing the active and regulatory sites were shown to be identical in both proteins.

  12. Improved performance of Nb-doped vanadyl pyrophosphate, catalyst for n-butane oxidation to maleic anhydride

    Energy Technology Data Exchange (ETDEWEB)

    Pavarelli, G.; Caldarelli, A.; Cavani, F. [Bologna Univ. (Italy). Dipt. di Chimica Industriale ' Toso Montanari' ; Cortelli, C.; Luciani, S. [Polynt SpA, Scanzorosciate (Italy)

    2013-11-01

    We report here about an investigation on the role of Nb{sup 5+} when used as a promoter for vanadyl pyrophosphate, catalyst for the oxidation of n-butane to maleic anhydride. The effect of Nb was very complex, a function of both its amount and the reaction temperature used. The optimal catalytic behavior was shown for very low Nb contents, i.e., for a V/Nb atomic ratio as low as 150. The main role of Nb was that of accelerating the formation of a limited amount of {gamma}-VOPO{sub 4} on the surface of vanadyl pyrophosphate, by accelerating the oxidation of V{sup 4+} into V{sup 5+} under reaction conditions. (orig.)

  13. Determination of Technetium-99 in Environmental Samples by Solvent Extraction at Controlled Valence

    DEFF Research Database (Denmark)

    Chen, Q.J.; Aarkrog, A.; Dahlgaard, H.

    1989-01-01

    Distribution coefficients of technetium and ruthenium are determined under different conditions with CCl4, cyclohexanone, and 5% tri-isooctylamine (TIOA)/xylene. A method for analyzing 99Tc in environmental samples has been developed by solvent extraction in which the valences of technetium...

  14. In vivo detection of multidrug-resistant (MDR1) phenotype by technetium-99m sestamibi scan in untreated breast cancer patients

    International Nuclear Information System (INIS)

    Del Vecchio, S.; Ciarmiello, A.; Potena, M.I.; Carriero, M.V.; Mainolfi, C.; Botti, G.; Thomas, R.; Cerra, M.; D'Aiuto, G.; Tsuruo, T.; Salvatore, M.

    1997-01-01

    Technetium-99m sestamibi is a transport substrate recognised by the multidrug-resistant P-glycoprotein (Pgp). To test whether 99m Tc-sestamibi efflux is enhanced in breast carcinomas overexpressing Pgp, we determined the efflux rates of 99m Tc-sestamibi and Pgp levels in tumours from 30 patients with untreated breast carcinoma. Patients were intravenously injected with 740 MBq of 99m Tc-sestamibi and underwent a 15-min dynamic study followed by the acquisition of static planar images at 0.5, 1, 2 and 4 h. Tumour specimens were obtained from each patient 24 h after 99m Tc-sestamibi scan and Pgp levels were determined using 125 I-MRK16 monoclonal antibody and in vitro quantitative autoradiography. All breast carcinomas showed high uptake of 99m Tc-sestamibi and data from region of interest analysis on sequential images were fitted with a monoexponential function. The efflux rates of 99m Tc-sestamibi, calculated from decay-corrected time-activity curves, ranged between 0.00121 and 0.01690 min -1 and were directly correlated with Pgp levels measured in the same tumours (r=0.62; P 99m Tc-sestamibi efflux from tumours of group A was 2.7 times higher than that observed in tumours of group B (0.00686 ±0.00390 min -1 vs 0.00250 ±0.00090 min -1 , P 99m Tc-sestamibi showed a sensitivity and a specificity of 80% and 95%, respectively. In conclusion, the efflux rate of 99m Tc-sestamibi may be used for the in vivo identification of the multidrug resistant (MDR1) phenotype in untreated breast cancer patients. (orig.). With 7 figs., 3 tabs

  15. The characteristics of pyrophosphate: D-fructose-6-phosphate 1-phosphotransferases from Sansevieria trifasciata leaves and Phaseolus coccineus stems.

    Science.gov (United States)

    Kowalczyk, S

    1987-01-01

    Three different molecular forms of pyrophosphate-dependent phosphofructokinase have been isolated: one from Sansevieria trifasciata leaves and two from Phaseolus coccineus stems. The form isolated from S. trifasciata has the molecular weight of about 115,000. The apparent molecular weights for the two forms from mung bean were approximately 220,000 and 450,000. All three forms have the same pH optima, an absolute requirement for Mg2+ ions both in the forward and reverse reaction, but differ in their sensitivity toward fructose 2,6-bisphosphate. Kinetic properties of the partially purified enzymes have been investigated in the presence and absence of fructose 2,6-bisphosphate. Pyrophosphate-dependent phosphofructokinase from S. trifasciata exhibited hyperbolic kinetics with all substrates tested. The saturation curves of the enzyme (form A) from mung bean for pyrophosphate, fructose 6-phosphate and fructose 1,6-bisphosphate were sigmoidal in the absence of fructose 2,6-bisphosphate. In the presence of fructose 2,6-bisphosphate these kinetics became hyperbolic.

  16. Definition and Reliability Assessment of Elementary Ultrasonographic Findings in Calcium Pyrophosphate Deposition Disease

    DEFF Research Database (Denmark)

    Filippou, Georgios; Scirè, Carlo A; Damjanov, Nemanja

    2017-01-01

    OBJECTIVE: To define the ultrasonographic characteristics of calcium pyrophosphate crystal (CPP) deposits in joints and periarticular tissues and to evaluate the intra- and interobserver reliability of expert ultrasonographers in the assessment of CPP deposition disease (CPPD) according to the ne...

  17. Separation, Concentration, and Immobilization of Technetium and Iodine from Alkaline Supernate Waste

    Energy Technology Data Exchange (ETDEWEB)

    James Harvey; Michael Gula

    1998-12-07

    Development of remediation technologies for the characterization, retrieval, treatment, concentration, and final disposal of radioactive and chemical tank waste stored within the Department of Energy (DOE) complex represents an enormous scientific and technological challenge. A combined total of over 90 million gallons of high-level waste (HLW) and low-level waste (LLW) are stored in 335 underground storage tanks at four different DOE sites. Roughly 98% of this waste is highly alkaline in nature and contains high concentrations of nitrate and nitrite salts along with lesser concentrations of other salts. The primary waste forms are sludge, saltcake, and liquid supernatant with the bulk of the radioactivity contained in the sludge, making it the largest source of HLW. The saltcake (liquid waste with most of the water removed) and liquid supernatant consist mainly of sodium nitrate and sodium hydroxide salts. The main radioactive constituent in the alkaline supernatant is cesium-137, but strontium-90, technetium-99, and transuranic nuclides are also present in varying concentrations. Reduction of the radioactivity below Nuclear Regulatory Commission (NRC) limits would allow the bulk of the waste to be disposed of as LLW. Because of the long half-life of technetium-99 (2.1 x 10 5 y) and the mobility of the pertechnetate ion (TcO 4 - ) in the environment, it is expected that technetium will have to be removed from the Hanford wastes prior to disposal as LLW. Also, for some of the wastes, some level of technetium removal will be required to meet LLW criteria for radioactive content. Therefore, DOE has identified a need to develop technologies for the separation and concentration of technetium-99 from LLW streams. Eichrom has responded to this DOE-identified need by demonstrating a complete flowsheet for the separation, concentration, and immobilization of technetium (and iodine) from alkaline supernatant waste.

  18. Diffusion of 99-technetium in bentonite under aerobic and anaerobic conditions

    International Nuclear Information System (INIS)

    Vecernik, P.; Jedinakova-Krizova, V.; Vokal, A.

    2006-01-01

    Diffusion experiments were performed with 99 Tc and Re (a model of technetium) in the form of pertechnetate and perrhenate in bentonite from the Rokle locality (Czech Republic). The through diffusion method was used, and the apparent diffusion coefficients (D a ) were evaluated. The effects of the particle mesh-size, bulk densities, and aerobic or anaerobic conditions on the diffusion were studied in view of the fact that oxidizing or reducing conditions influence the chemical forms of technetium and rhenium. In the presence of oxygen, technetium and rhenium occur in oxidation state VII, as anions which are soluble and mobile in the environment, whereas in reducing conditions they occur in lower oxidation states, mainly as insoluble oxides or hydroxides. Aerobic experiments were carried out in common laboratory conditions, anaerobic experiments were performed under nitrogen

  19. Experimental studies on the uptake of technetium-99 to terrestrial crops

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Joanne; Ewers, Leon [Centre for Radiation, Chemical and Environmental Hazards, Public Health England (United Kingdom)

    2014-07-01

    Technetium-99 has been dispersed in the environment from many sources such as nuclear weapons testing, releases from medical or industrial processes, nuclear power plants and nuclear fuel processing facilities. The pertechnetate ion, {sup 99}TcO{sub 4}{sup -} is the form produced during the nuclear fuel cycle and the most likely to be released into the environment. A recent review published by Public Health England (formerly the Health Protection Agency) found that the availability for the root uptake of technetium into crops depends on whether the technetium is in a chemically non-reduced more plant available form, such as TcO{sub 4}{sup -} or a chemically reduced less plant available form, such as TcO{sub 2}. Based on the review, generic soil to crop transfer factor (TF) values for use in non-site specific UK based radiological assessments were proposed, with the TF value for the reduced form of technetium in crops around a factor of 10 lower than that for the non-reduced form. The implications of the use of different TF values on the activity concentrations in crops and animal products predicted by PHE's food chain model, FARMLAND, for both routine and accidental release situations were explored. Recommendations on the best choice of TF values for use in the model have been given for a range of contamination scenarios. A small scale experimental study has been carried out to provide further evidence that the generic assumption made on the difference between soil-crop TF values for non-reduced and reduced forms of technetium is valid. The study was also designed to establish likely time periods over which the chemical reduction of technetium takes place and to provide additional soil-crop TF values for use in UK based radiological assessments. Soil to crop TFs for crops harvested from loam and peat soils up to 4 months after contamination are about a factor of 10 higher than those seen in soil contaminated more than a year previously, indicating that the

  20. Fever of unknown origin and the value of gallium-67 and technetium-99/sup m/ for defining abnormality of the spleen: a case report

    International Nuclear Information System (INIS)

    Coopersmith, A.; Ritchey, A.K.; Zinkham, W.H.

    1975-01-01

    A three-year-old white female with acute promyelocytic leukemia developed persistent fever after successful induction-remission therapy; many large monilial abscesses were later found in the grossly enlarged spleen. Although the technetium/sup 99M/-sulfur colloid scan prior to splenectomy suggested only a slight abnormality of the spleen, the gallium-67 citrate scintigraph showed a marked increase in gallium accumulation. The disparate results of the scanning techniques utilized in this patient suggest that it may be necessary to use more than one type of radiopharmaceutical to define an enlarged spleen, as well as the pathological process responsible for its enlargement

  1. Transmutation of technetium into stable ruthenium in high flux conceptual research reactor

    International Nuclear Information System (INIS)

    Amrani, N.; Boucenna, A.

    2007-01-01

    The effectiveness of transmutation for the long lived fission product technetium-99 in high flux research reactor, considering its large capture cross section in thermal and epithermal region is evaluated. The calculation of Ruthenium concentration evolution under irradiation was performed using Chain Solver 2.20 code. The approximation used for the transmutation calculation is the assumption that the influence of change in irradiated materials structures on the reactor operator mode characteristics is insignificant. The results on Technetium transmutation in high flux research reactor suggested an effective use of this kind of research reactors. The evaluation brings a new concept of multi-recycle Technetium transmutation using HFR T RAN (High Flux Research Reactor for Transmutation)

  2. Applications and interpretation of krypton 81m ventilation/technetium 99m macroaggregate perfusion lung scanning in childhood

    Science.gov (United States)

    Davies, Hugh Trevor Frimston

    Radionuclide ventilation perfusion lung scans now play an important part in the investigation of paediatric lung disease, providing a safe, noninvasive assessment of regional lung function in children with suspected pulmonary disease. In paediatric practice the most suitable radionuclides are Krypton 81m (Kr81m) and Technetium 99m (Tc99m), which are jointly used in the Kr81m ventilation/Tc99m macroaggregate perfusion lung scan (V/Q lung scan). The Kr81m ventilation scan involves a low radiation dose, requires little or no subject cooperation and because of the very short half life of Kr81m (13 seconds) the steady state image acquired during continuous inhalation of the radionuclide is considered to reflect regional distribution of ventilation. It is now the most important noninvasive method available for the investigation of the regional abnormalities of ventilation characteristic of many congenital and acquired paediatric respiratory diseases, such as diaphragmatic hernia, pulmonary sequestration, bronchopulmonary dysplasia, foreign body inhalation and bronchiectasis. It improves diagnostic accuracy, aids clinical decision making and is used to monitor the progress of disease and response to therapy. Theoretical analysis of the steady state Kr81m ventilation image suggests that it may only reflect regional ventilation when specific ventilation (ventilation per unit volume of lung) is within or below the normal adult range (1-3 L/L/min). At higher values such as those seen in neonates and infants (8-15 L/L/min) Kr81m activity may reflect regional lung volume rather than ventilation, a conclusion supported by the studies of Ciofetta et al. There is some controversy on this issue as animal studies have demonstrated that the Kr81m image reflects ventilation over a much wider range of specific ventilation (up to 13 L/L/min). A clinical study of sick infants and very young children is in agreement with this animal work and suggests that the steady state Kr81m image

  3. Technetium 99-m labeled radio-diagnostic agents employing stannous tartrate and method of preparation

    International Nuclear Information System (INIS)

    Molinski, V.J.; Wilczewski, J.A.

    1976-01-01

    A method of preparing improved technetium-99m labeled radiodiagnostic agents by reducing technetium-99m with stannous tartrate. Such radiodiagnostic agents are useful in scintigraphic examinations of the bone and lung. 31 claims, no drawings

  4. The radiochemical purity of technetium-99m-tin-diethylene-triamino-pentaacetic acid (DTPA) complex

    International Nuclear Information System (INIS)

    Besnard, M.; Costerousse, O.; Merlin, L.; Coehn, Y.

    1975-01-01

    The effect on radiochemical purity was studied as a function of the storage period of tin-DTPA solution and of the technetium-complex solution. The quantity of the pertechnetate ions present in the solution is determined by ascending paper chromatography, and an attempt was made to clarify the bond type of technetium by a spectrophotometric method. The tin-DTPA solutions for complexing of the reduced technetium are stable over a period of 8 weeks. The yield of the radiopharmaceutical product is better than 95%. (G.Gy.)

  5. Preparation of a generator of technetium-99m

    International Nuclear Information System (INIS)

    Jimeno de Osso, F.

    1981-01-01

    Practical description is given of equipment and operations necessary in the preparation of an isotopic generator of technetium-99m. The preparation and application of the active solution and throughly washed of the chromatographic column have been studied in order to allow molibdenum-99 to be adsorbed on a small band, and the solution of tectium-99m to be eluted with high efficiency and purity. The equipment and accesories used are easy and safety to manage, simplifying operations to be carried out with the active product, eliminating the sterile environment in the shielded cell, and facilitating the preparation of the solution of technetium-99m in sterile and pyrogen-free conditions.(author) [es

  6. Effect of intra-articular yttrium-90 on chronic pyrophosphate arthropathy of the knee

    International Nuclear Information System (INIS)

    Doherty, M.; Dieppe, P.A.

    1981-01-01

    Fifteen patients with bilateral, symmetrical chronic pyrophosphate arthropathy of the knee were given intra-articular injections of yttrium-90 (5 mCi) plus steroid (triamcinolone hexacetonide, 20 mg) into one knee, and saline plus steroid into the other (control) knee. Allocation of the 90 Y injection was random and double blind. After 6 months there was significantly less pain, inactivity stiffness, joint-line tenderness, and effusion in the 90 Y-injected knees than in the controls (p 90 Y-injected and control knees in the changes in range of movement (p 90 Y may be of benefit in chronic pyrophosphate arthropathy, a disease for which there is no treatment. The predilection of this condition to affect the knees of the elderly makes such treatment highly suitable because the joint lends itself readily to injection and the procedure carries very few actual or potential risks in this age group. (author)

  7. Arterial scan versus radiographic angiography in detection of shallow arterial ulcers

    International Nuclear Information System (INIS)

    Pollak, E.W.; Webber, M.M.; Cragin, M.D.; Wolfman, E.F. Jr.

    1977-01-01

    A comparison of 99m-technetium albumin aggregated arterial scan and radiographic angiography for detection of shallow intimal carotid artery ulcerations was made in a series of 12 anesthetized dogs, having a total of 16 acute arterial ulcerations. Radiographic angiography showed positive findings related to presence of stenosis or mural thrombosis in 12 instances. Direct visualization of ulceration was only exceptionally encountered. Arterial scan detected 14 of 16 intimal ulcers. The radionuclide method was reliable even in absence of stenosis or when only minimal mural thrombosis was present. Moreover, autopsy scan of the isolated arterial segments detected all 16 intimal lesions. These results indicate that the arterial scan was a more reliable method for detection of shallow arterial ulcers in this experimental model than radiographic angiography, especially when arterial lumen stenosis or mural thrombosis was minimal or absent

  8. Structure of human farnesyl pyrophosphate synthase in complex with an aminopyridine bisphosphonate and two molecules of inorganic phosphate

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jaeok [McGill University, 3655 Promenade Sir William Osler, Montreal, QC H3G 1Y6 (Canada); Lin, Yih-Shyan [McGill University, 801 Rue Sherbrooke Ouest, Montreal, QC H3A 0B8 (Canada); Tsantrizos, Youla S. [McGill University, 3655 Promenade Sir William Osler, Montreal, QC H3G 1Y6 (Canada); McGill University, 801 Rue Sherbrooke Ouest, Montreal, QC H3A 0B8 (Canada); McGill University, 3649 Promenade Sir William Osler, Montreal, QC H3G 0B1 (Canada); Berghuis, Albert M., E-mail: albert.berghuis@mcgill.ca [McGill University, 3655 Promenade Sir William Osler, Montreal, QC H3G 1Y6 (Canada); McGill University, 3649 Promenade Sir William Osler, Montreal, QC H3G 0B1 (Canada); McGill University, 3775 Rue University, Montreal, QC H3A 2B4 (Canada)

    2014-02-19

    A co-crystal structure of human farnesyl pyrophosphate synthase in complex with an aminopyridine bisphosphonate, YS0470, and two molecules of inorganic phosphate has been determined. The identity of the phosphate ligands was confirmed by anomalous diffraction data. Human farnesyl pyrophosphate synthase (hFPPS) produces farnesyl pyrophos@@phate, an isoprenoid essential for a variety of cellular processes. The enzyme has been well established as the molecular target of the nitrogen-containing bisphosphonates (N-BPs), which are best known for their antiresorptive effects in bone but are also known for their anticancer properties. Crystal structures of hFPPS in ternary complexes with a novel bisphosphonate, YS0470, and the secondary ligands inorganic phosphate (P{sub i}), inorganic pyrophosphate (PP{sub i}) and isopentenyl pyrophosphate (IPP) have recently been reported. Only the co-binding of the bisphosphonate with either PP{sub i} or IPP resulted in the full closure of the C-@@terminal tail of the enzyme, a conformational change that is required for catalysis and that is also responsible for the potent in vivo efficacy of N-BPs. In the present communication, a co-crystal structure of hFPPS in complex with YS0470 and two molecules of P{sub i} is reported. The unusually close proximity between these ligands, which was confirmed by anomalous diffraction data, suggests that they interact with one another, with their anionic charges neutralized in their bound state. The structure also showed the tail of the enzyme to be fully disordered, indicating that simultaneous binding of two P{sub i} molecules with a bisphosphonate cannot induce the tail-closing conformational change in hFPPS. Examination of homologous FPPSs suggested that this ligand-dependent tail closure is only conserved in the mammalian proteins. The prevalence of P{sub i}-bound hFPPS structures in the PDB raises a question regarding the in vivo relevance of P{sub i} binding to the function of the enzyme.

  9. Pyrophosphate as a central energy carrier in the hydrogen-producing extremely thermophilic Caldicellulosiruptor saccharolyticus

    NARCIS (Netherlands)

    Bielen, A.A.M.; Willquist, K.; Engman, J.; Oost, van der J.; Niel, van E.W.J.; Kengen, S.W.M.

    2010-01-01

    The role of inorganic pyrophosphate (PPi) as an energy carrier in the central metabolism of the extremely thermophilic bacterium Caldicellulosiruptor saccharolyticus was investigated. In agreement with its annotated genome sequence, cell extracts were shown to exhibit PPi-dependent

  10. Effect of humic acid on sorption of technetium by alumina

    International Nuclear Information System (INIS)

    Kumar, S.; Rawat, N.; Kar, A.S.; Tomar, B.S.; Manchanda, V.K.

    2011-01-01

    Highlights: → Tc sorption on alumina has been studied under aerobic as well anaerobic condition over pH 3-10. → Effect of humic acid on sorption of Tc by alumina has been investigated. → Linear additive modeling and surface complexation modeling were carried out to delineate the role of humic acid in Tc(IV) sorption in ternary system of Tc(IV)-humic acid-alumina. → Sorption of humic acid onto alumina and strong complexation of Tc(IV) with humic acid were found to govern the sorption of Tc(IV) in the ternary system. - Abstract: Sorption of technetium by alumina has been studied in absence as well as in presence of humic acid using 95 Tc m as a tracer. Measurements were carried out at fixed ionic strength (0.1 M NaClO 4 ) under varying pH (3-10) as well as redox (aerobic and reducing anaerobic) conditions. Under aerobic conditions, negligible sorption of technetium was observed onto alumina both in absence and in presence of humic acid. However, under reducing conditions (simulated with [Sn(II)] = 10 -6 M), presence of humic acid enhanced the sorption of technetium in the low pH region significantly and decreased at higher pH with respect to that in absence of humic acid. Linear additive as well as surface complexation modeling of Tc(IV) sorption in presence of humic acid indicated the predominant role of sorbed humic acid in deciding technetium sorption onto alumina.

  11. Molecular cloning and expression of Chimonanthus praecox farnesyl pyrophosphate synthase gene and its possible involvement in the biosynthesis of floral volatile sesquiterpenoids.

    Science.gov (United States)

    Xiang, Lin; Zhao, Kaige; Chen, Longqing

    2010-01-01

    Farnesyl pyrophosphate (FPP) synthase catalyzes the biosynthesis of FPP, which is the precursors of sesquiterpenoids such as floral scent volatiles, from isopentenyl pyrophosphate (IPP) and dimethylallyl pyrophosphate (DMAPP). cDNA encoding wintersweet (Chimonanthus praecox L.) FPP synthase was isolated by the RT-PCR and RACE methods. The deduced amino acid sequence showed a high identity to plant FPP synthases. Expression of the gene in Escherichia coli yielded FPPS activity that catalyzed the synthesis of FPP as a main product. Tissue-specific and developmental analyses of the mRNA levels of CpFPPS and volatile sesquiterpenoids levels in C. praecox flowers revealed that the FPPS may play a regulatory role in floral volatile sesquiterpenoids of wintersweet. Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  12. Chemical form of technetium in corn (Zea mays) and the gastrointestinal absorption of plant-incorporated Tc by laboratory rats

    Energy Technology Data Exchange (ETDEWEB)

    Garten, C.T. Jr.; Myttenaere, C.; Vandecasteele, C.M.; Kirchmann, R.; Van Bruwaene, R.

    1984-01-01

    The food chain availability of technetium incorporated into plant tissue, its chemical form in corn leaves, and the potential for gastrointestinal absorption of plant-incorporated technetium was investigated. Technetium-95m was incorporated into corn leaves via root uptake. Chemical fractionation of the /sup 95m/Tc in leaves showed that 60% was extractable with boiling ethanol and weak mineral acids. The remainder was associated with cell walls and was extractable by harsh chemical treatment. Gel permeation chromatography of the cytosol, indicated that 50% of the /sup 95m/Tc co-chromatographed with anionic pertechnetate; however, it was impossible to distinguish if this pure pertechnetate or technetium complexed with organic molecules. Technetium-95m was administered to laboratory rats in a single dose as: (1) intravenous injection of pertechnetate, (2) pertechnetate mixed with standard laboratory food, and (3) a meal containing /sup 95m/Tc biologically incorporated into corn leaves. High concentrations of /sup 95m/Tc were found in the thyroids, hair, kidneys, and liver of rats. Technetium rapidly disappeared from the liver, kidneys, and other tissues, but remained in the thyroids and hair. Urinary excretion of technetium decreased, and fecal excretion increased when technetium was fed to rats as a /sup 95m/Tc incorporated into corn leaves. The percent of the administered dose absorbed into thyroid gland and the kidneys was less when technetium was biologically incorporated into corn leaves than when pertechnetate was mixed with food. Biological incorporation of technetium into plants appears to reduce its potential for food chain transfer by decreasing its availability for gastrointestinal absorption. 5 references, 4 figures, 3 tables.

  13. Chemical form of technetium in corn (Zea mays) and the gastrointestinal absorption of plant-incorporated Tc by laboratory rats

    International Nuclear Information System (INIS)

    Garten, C.T. Jr.; Myttenaere, C.; Vandecasteele, C.M.; Kirchmann, R.; Van Bruwaene, R.

    1984-01-01

    The food chain availability of technetium incorporated into plant tissue, its chemical form in corn leaves, and the potential for gastrointestinal absorption of plant-incorporated technetium was investigated. Technetium-95m was incorporated into corn leaves via root uptake. Chemical fractionation of the /sup 95m/Tc in leaves showed that 60% was extractable with boiling ethanol and weak mineral acids. The remainder was associated with cell walls and was extractable by harsh chemical treatment. Gel permeation chromatography of the cytosol, indicated that 50% of the /sup 95m/Tc co-chromatographed with anionic pertechnetate; however, it was impossible to distinguish if this pure pertechnetate or technetium complexed with organic molecules. Technetium-95m was administered to laboratory rats in a single dose as: (1) intravenous injection of pertechnetate, (2) pertechnetate mixed with standard laboratory food, and (3) a meal containing /sup 95m/Tc biologically incorporated into corn leaves. High concentrations of /sup 95m/Tc were found in the thyroids, hair, kidneys, and liver of rats. Technetium rapidly disappeared from the liver, kidneys, and other tissues, but remained in the thyroids and hair. Urinary excretion of technetium decreased, and fecal excretion increased when technetium was fed to rats as a /sup 95m/Tc incorporated into corn leaves. The percent of the administered dose absorbed into thyroid gland and the kidneys was less when technetium was biologically incorporated into corn leaves than when pertechnetate was mixed with food. Biological incorporation of technetium into plants appears to reduce its potential for food chain transfer by decreasing its availability for gastrointestinal absorption. 5 references, 4 figures, 3 tables

  14. Scintigraphic diagnosis of experimentally induced pericarditis in dogs using 99sup(m)Tc-labelled pyrophosphate

    International Nuclear Information System (INIS)

    Duska, F.; Novak, J.; Vizda, J.; Kubizek, J.; Simon, J.; Veverkova, O.; Karlova Universita, Hradec Kralove

    1981-01-01

    In the present paper the possibilities of scintigraphic diagnosis of experimental pericarditis are discussed. Pericarditis was induced by either talc or formaldehyde intrapericardially. In all animals the administration of talc as well as formaldehyde produced inflammatory changes which were more serious after formaldehyde. The scan of the talc pericarditis was carried out on the 7th day after operation and of the formaldehyde pericarditis on the 3rd, 7th and 14th day. No positive scintigraphic finding was made in any of the experimental animals, apart from a massive incorporation in the operation scars. The counting of radioactive impulses after the exstirpation of the tissue samples confirmed the scintigraphic findings. Statistical evaluation did not reveal any essential difference between the accumulation of the radiopharmaceutical into the pericarditis as well as into the pericardial bag in comparison with the control animals. Although our model does not exactly reflect the situation of patients suffering from pericarditis it may be assumed that pyrophosphate scintigraphy is not suitable for the diagnosis of acute pericarditis in clinical practice. (orig.) [de

  15. The role of Technetium99m-MIBI in the follow-up of differentiated thyroid carcinoma

    International Nuclear Information System (INIS)

    Machado, L.S.; Corbo, R.; Pedras, D.S.V.; Anttonuccia, J.B.

    2004-01-01

    Full text: Technetium-99m-methoxyisobutylisonitrile (99mTc-MIBI) is being used as a tumor-seeking agent over the last few years. We evaluated the role of 99mTc-MIBI whole body scan (WBS) in localizing metastatic lesions in patients with thyroid cancer and compared the results with 131I scan and serum thyroglobulin (Tg) levels. Eighty nine patients of differentiated thyroid cancer subjected to thyroidectomy were enrolled for the study. Early (20 minutes) and delayed (6 and 24 hours) whole body images were obtained after injecting 99mTc-MIBI. Tg measurements were obtained during thyroid hormone replacement and 4 weeks after hormone discontinuation. 131I scans were performed after low diagnostic or high ablative/therapeutic dose. These methods were used as standard to evaluate the presence of residual or metastatic thyroid cancer. The patients with positive 99mTc-MIBI scan but negative 131I scan underwent chest x-ray, computed tomography (CT) or magnetic resonance imaging (MRI). 34 of the total 89 patients were found to be negative on 131I scan. 23 of these 34 patients had negative 99mTc-MIBI WBS and 11 patients were positive for abnormal MIBI uptake (specificity: 67.6%). Twenty-two patients had both 99mTc-MIBI WBS and 131I scan positive. Eleven patients had 131I scan negative and 99mTc-MIBI WBS positive; seven of those proved to be true positive. From the findings of our study, it may be concluded that although 99mTc-MIBI has low sensitivity for detection of tumor recurrence, it definitely has a role as a supplementary tool to thyroglobulin measurements and 131I scans. (author)

  16. Evolution of technetium speciation in reducing grout

    Energy Technology Data Exchange (ETDEWEB)

    Lukens, Wayne W.; Bucher, Jerome J.; Shuh, David K.; Edelstein,Norman M.

    2003-11-24

    Cementitious waste forms (CWFs) are an important component of the strategy to immobilize high-level nuclear waste resulting from plutonium production by the U.S. Department of Energy (DOE). Technetium (99Tc) is an abundant fission product of particular concern in CWFs due to the high solubility and mobility of pertechnetate, TcO4-, the stable form of technetium in aerobic environments. CWFs can more effectively immobilize 99Tc if they contain additives that reduce mobile TcO4- to immobile Tc(IV) species. Leaching of 99Tc from reducing CWFs that contain Tc(IV) is much slower than for CWFs containing TcO4-. Previous X-ray absorption fine structure (XAFS) studies showed that the Tc(IV) species were oxidized to TcO4- in reducing grout samples prepared on a laboratory scale. Whether the oxidizer was atmospheric O2 or NO3- in the waste simulant was not determined. In actual CWFs, rapid oxidation of Tc(IV) by NO3- would be a concern, whereas oxidation by atmospheric O2 would be of less concern due to the slow diffusion and reaction of O2 with the reducing CWF. To address this uncertainty, two series of reducing grouts were prepared using TcO4- containing waste simulants with and without NO3-. In the first series of samples, the TcO4- was completely reduced using Na2S, and the samples were placed in containers that permitted O2 diffusion. In these samples, all of the technetium was initially present as aTc(IV) sulfide compound, TcSx, which was characterized using extended X-ray absorption fine structure (EXAFS) spectroscopy, and is likely Tc2S7. The TcSx initially present in the grout samples was steadily oxidized over 4 years. In the second series of samples, all of the TcO4- was not initially reduced, and the grout samples were placed in airtight containers. In these samples, the remaining TcO4- continued to be reduced as the samples aged, presumably due to the presence of reducing blast furnace slag. When samples in the second series were exposed to atmosphere, the

  17. Role of morphine administration with 99m-technetium-labelled di-isopropyl iminodiacetic acid in the diagnosis of acute cholecystitis

    International Nuclear Information System (INIS)

    Louridas, G.; Botha, J.R.; Esser, J.D.; Savitch, I.; Vas, M.; Levin, J.; Myburgh, J.A.

    1987-01-01

    Patients presenting with a clinical diagnosis suggestive of acute cholecystitis had a 99m-technetium-labelled di-isopropyl iminodiacetic acid (DISIDA) scan. Two groups of patients were investigated. In group 1, 66 patients underwent cholescintigraphy and after 60 minutes morphine was given to all patients whose gallbladders had not filled. The accuracy rate of this procedure was 91%, sensitivity 83%, specificity 97%, positive predictive value 96,2% and negative predictive value 87,5%. In group 2, 97 patients had cholescintigraphy with morphine being administered at the beginning of the procedure. The accuracy rate of this investigation was 97,9%, sensitivity 100%, specificity 96,6%, positive predictive value 95% and negative predictive value 100%. We recommend the early use of morphine in all patients undergoing a DISIDA scan for acute cholecystitis

  18. Sorption behaviour of radioactive technetium in soils

    International Nuclear Information System (INIS)

    Xia Deying

    1996-01-01

    The sorption behaviour of technetium in different soils has been studied by batch experiments under aerobic conditions. The soil samples have been taken to study the characteristics and to derive the pH-Eh values. In addition, the activated carbon and reduced iron powder have been selected as additives to the JAERI sand according to the former research work, so that the technetium sorption behaviour in the artificial soils can be studied under similar conditions. The experimental results show that all these soil samples except for the gluey soil have a very small distribution coefficient for Tc, while the artificial soils have a very large distribution coefficient for Tc. Besides, for artificial soils, the distribution coefficient (R d ) values will become larger and larger when more additive is added and more contact time is allowed. The physico-chemical fixation processes and possible sorption modes have been discussed as well

  19. Studies in radioaerosol lung scanning in urban health survey subjects

    International Nuclear Information System (INIS)

    Doshi, V.B.; Gregat, I.K.; Kamat, S.R.; Papewar, V.N.; Raikar, U.R.; Sharma, S.M.; Ganatra, R.D.

    1984-01-01

    As a part of health survey in relation to air pollution, 16 smokers(11 from 'high' and 5 from 'low' zone) were studied with extensive serial lung functions, chest radiography and radioaerosol lung scanning. The clinical diagnosis were chronic bronchitis(COPD) in 9 subjects; but others (4 'High' and 3 'Low') were considered normal. The values of FVC, FEV were normal in most of these three groups, but FEV 1 /FVC percent values were lower in subjects from 'high' zone.The functional declines were higher in normals of 'high' zone. Radioaerosol (ventilation) scans (with technetium 99 ) showed a normal picture in 2 COPD and 3 normal subjects; in 3 COPD and 1 normal subjects the abnormalities were definite. For perfusion scans, 2 COPD and 3 normal subjects showed a normal pattern while definite abnormalities were seen in 1 COPD and 1 normal subjects. Lung scans may pick up abnormalities in normal smokers at an early stage. (author)

  20. Technetium-labeled HM-PAO studies in patients with cerebrovascular disease

    International Nuclear Information System (INIS)

    Smith, F.W.; Sharp, P.F.; Gemmell, H.; Evans, N.T.; MacDonald, A.F.

    1986-01-01

    Technetium-labeled hexamethyl-propyleneamineoxime (HM-PAO) is a promising radiopharmaceutical for the demonstration of cerebral blood flow. Twenty-four patients who had experienced either acute stroke (AS) or transient ischemic attack (TIA) were studied by x-ray CT and SPECT using technetium-labeled HM-PAO total of 26 studies. HM-PAO has a cerebral distribution similar to that of iodoamphetamine, but labeling with technetium allows good SPECT imaging on demand in any nuclear medicine department. In ten of the 16 patients who had experienced AS, findings on HM-PAO and CT studies correlated well. In six patients reduced cortical perfusion was detected on HM-PAO imaging, but only small infarcts in the internal capsule were seen on CT. In four of the eight patients who had experienced TIA, neither study revealed any abnormality. In the remaining four, areas of cortical underperfusion were seen on HM-PAO imaging, whereas the CT examination was normal. The findings in this study suggest that HM-PAO imaging is a more sensitive method for demonstrating the extent of cerebral underperfusion in cases of cerebrovascular accident

  1. An investigation of the effect of the quantity of stannous ion on the quality of technetium-99m labelled albumin

    International Nuclear Information System (INIS)

    Billinghurst, M.W.; Rempel, S.; Westendorf, B.A.

    1981-01-01

    The importance of maintaining a low ratio of stannous ion to albumin molecules in order to obtain a high quality technetium-99m labelled albumin is demonstrated. It is further shown that the direct preparation of technetium-99m albumin by reduction of the technetium-99m pertechnetate with stannous ion inevitably leads to the contamination of the product with a certain amount of tin colloid which is also labelled with technetium-99m. It is demonstrated that this can be avoided by utilizing labelling techniques involving the initial formation of other technetium chelates which are less stable than the albumin complex under certain conditions, adding the albumin to that preparation, adjusting the conditions and thus allowing the albumin to become labelled with technetium-99m via an exchange with the original chelating agent. (author)

  2. A method for the preparation of lipophilic macrocyclic technetium-99m complexes

    International Nuclear Information System (INIS)

    Troutner, D.E.; Volkert, W.A.

    1991-01-01

    A procedure for the preparation of technetium complexes applicable as diagnostic radiopharmaceuticals is suggested and documented with 27 examples. Technetium-99m is reacted with a suitable complexant selected from the class of alkylenamine oximes containing 2 or 3 carbon atoms in the alkylene group. The lipophilic macrocyclic complexes possess an amine, amide, carboxy, carboxy ester, hydroxy or alkoxy group or a suitable electron acceptor group. (M.D.). 7 tabs

  3. Measurement of glomerular filtration rate in children using technetium-99m diethylenetriamine penta-acetic acid

    International Nuclear Information System (INIS)

    Aaronson, I.A.; Mann, M.D.

    1985-01-01

    During the past 5 years, we have measured the glomerular filtration rate (GFR) by the slope-clearance method using technetium-99m diethylenetriamine penta-acetic acid technetium-99m-DTPA in 130 infants and children. The results in 22 children have been compared with inulin clearance, and a very good correlation between the two methods of measurement of GFR was demonstrated (r = 0,9616; P less than 0,0001). This study provides further evidence that technetium-99m-DTPA is a satisfactory agent for the clinical measurement of GFR in children

  4. Molybdenum and technetium cycle in the environment. Physical chemical evolution and mobility in soils and plants

    International Nuclear Information System (INIS)

    Saas, A.; Denardi, J.L.; Colle, C.; Quinault, J.M.

    1980-01-01

    Molybdenum 99 and technetium 99 from liquid discharges of base nuclear installations (reactors, reprocessing plants, UF 6 treatment, etc.) can reach the environment via irrigation waters and atmospheric deposits. The contribution to the soil by irrigation results in a physical-chemical transformation, the results of which, in the case of technetium 99, could be volatilization via microbes. The changes in the physical-chemical forms of technetium in different soils reveals the preponderant effect of the initial amount deposited. The determination of the rate of technetium and molybdenum assimilation shows a certain similarity in behaviour; yet the localization of these isotopes is not the same. The transfer of molybdenum and technetium via the root system is different in its intensity; this is mainly due to different physical-chemical forms. Finally, each isotope has an optimum assimilation threshold and a toxicity threshold. The study of the physical-chemical evolution and the mobility in the soil-plant-water table system of these two isotopes shows a new aspect with respect to certain transfer channels to the human being [fr

  5. Study on interference of technetium in spectrophotometric estimation of uranium

    International Nuclear Information System (INIS)

    Revathi, P.; Saipriya, K.; Madhavan Kutty, V.K.; Srinivasa Rao, G.; Vijayakumar, N.; Kumar, T.

    2015-01-01

    Estimation of uranium is essential for process control purposes as well as to arrive optimum parameters for further waste management in reprocessing industry. Uranium estimation is done by spectrophotometry using ammonium thiocyanate, DBM, PAR and Br-PADAP as chromogenic reagents for colour development. Extractive spectrophotometry can also be used to eliminate some of the interfering ions. During inter method comparison, technetium was found to be interfering in the thiocyanate spectrophotometry. This study is an effort to find out the extent of technetium interference in the estimation of uranium by spectrophotometry using the above said chromogenic reagents. (author)

  6. Performance testing of blast furnace slag for immobilization of technetium in grout

    International Nuclear Information System (INIS)

    Gilliam, T.M.; Spence, R.D.; Evans-Brown, B.S.; Morgan, I.L.; Shoemaker, J.L.; Bostick, W.D.

    1988-01-01

    This paper presents preliminary results of a grout development effort to identify grout formulas that can satisfactorily sequester 99 Tc contained in an existing Portsmouth Gaseous Diffusion Plant waste. Technetium is of particular concern to the US Nuclear Regulatory Commission (NRC) because of its mobility and biological activity. The mobility of technetium results in large part from the movement of the pertechnate anion [prevalent in low-level radioactive waste (LLW)] through soil and geologic strata with little or no interaction with the surrounding matrix. Ground blast furnace slag has been shown to improve the leach resistance of cement-based waste forms, particularly in regard to technetium. This improved performance has been attributed to fewer and smaller pores in the solidified slags (versus a neat cement paste) and to the reduction of the pertechnate ion to a less soluble form. 9 refs., 2 tabs

  7. Childhood acute lymphoblastic leukemia presenting as ''cold'' lesions on bone scan: a report of two cases

    International Nuclear Information System (INIS)

    Caudle, R.J.; Crawford, A.H.; Gelfand, M.J.; Gruppo, R.A.

    1987-01-01

    ''Cold'' lesions on bone scan have been reported in a variety of disease processes, including infection, avascular necrosis, and cysts. We present two cases of children who presented with large ''cold'' areas on technetium bone scans and were treated initially for septic processes. Acute childhood leukemia frequently presents with bone or joint pain, fever, and elevation of the erythrocyte sedimentation rate. Although the diagnosis may be difficult if the characteristic clinical signs and laboratory findings are absent, the presence of anemia should alert the physician to the possibility of malignancy. Bone scanning provides a sensitive method of localizing pathology, but diagnosis requires biopsy or marrow aspiration

  8. Obtention of scintillography images by low density lipoproteins labelled with technetium 99

    International Nuclear Information System (INIS)

    Silva, S.; Coelho, I.; Zanardo, E.; Pileggi, F.; Meneguethi, C.; Maranhao, R.C.

    1992-01-01

    The low density lipoproteins carry the most part of the cholesterol in the blood plasma. These lipoproteins are labelled with technetium-99-m and have been used for obtaining images in nuclear medicine. The introduction of this technique is presented, aiming futures clinical uses. Scintillographic images are obtained 25 minutes and 24 hours after the injection of 3 m Ci of low density lipoproteins - technetium-99 m in rabbits. (C.G.C.)

  9. Liver scanning in the diagnosis of metastases from malignant tumors of the gastrointestinal tract

    International Nuclear Information System (INIS)

    Fleites, G.; Gomez, E.; Bell, L.; Peralta, R.; Suarez, J.C.; Cassola, J.R.; Fraga, A.

    1989-01-01

    The National Institute of Oncology and Radiobiology (INOR) established a line of clinical investigation in January, 1974, which was later added to clinical care. This line consisted of trying to arrive at a preoperative diagnosis - by means of liver scanning - of the potential liver metastases of primitive tumors in the gastrointestinal tract. Metastable 113 Indium was used. A review of the results obtained in the 50 patients included in the investigation program is made. The results of preoperative scanning were compared with operative findings. Twelve liver metastases (24%) were found. In 40 patients there was agreement (80%) between preoperative scanning and operatory findings. At present, ultrasound is a necessary supplement to scans, which supplements it but does not exclude it. The tracer element used now is technetium-99 M coloidal sulphide

  10. Evaluation of the use of technetium Tc 99m diethylenetriamine pentaacetic acid and technetium Tc 99m dimercaptosuccinic acid for scintigraphic imaging of the kidneys in green iguanas (Iguana iguana).

    Science.gov (United States)

    Greer, Leah L; Daniel, Gregory B; Shearn-Bochsler, Valerie I; Ramsay, Edward C

    2005-01-01

    To evaluate the use of scintigraphy involving technetium Tc 99m diethylenetriamine pentaacetic acid ((99m)Tc-DTPA) or technetium Tc 99m dimercaptosuccinic acid ((99m)Tc-DMSA) for the determination of kidney morphology and function in green iguanas (Iguana iguana). 10 healthy iguanas weighing >1.6 kg. Renal scintigraphy was performed by use of (99m)Tc-DTPA in 6 of the iguanas and by use of (99m)Tc-DMSA in all 10 iguanas. After the injection of (99m)Tc-DMSA, scans were performed for each iguana at intervals during a 20-hour period. Renal biopsies were performed in all 10 iguanas after the final scintigraphic evaluation. In iguanas, the use of (99m)Tc-DTPA for renal scintigraphy was nondiagnostic because of serum protein binding and poor renal uptake of the isotope; mean +/- SD (99m)Tc-DTPA bound to serum proteins was 48.9 +/- 9.9%. Renal uptake of (99m)Tc-DMSA produced distinct visualization of both kidneys. Renal uptake and soft tissue clearance of (99m)Tc-DMSA increased over the 20-hour imaging period; mean +/- SD renal uptake of (99m)Tc-DMSA was 11.31 +/- 3.06% at 20 hours. In each of the 10 iguanas, ultrasonographic and histologic examinations of biopsy specimens from both kidneys revealed no abnormalities. Results indicate that the kidneys of iguanas can be evaluated scintigraphically by use of (99m)Tc-DMSA; this technique may be potentially useful for the diagnosis of renal failure in iguanas.

  11. Quantitative bone scanning after asymptomatic Charnley arthroplasty

    International Nuclear Information System (INIS)

    Mullaji, A.B.; Tood, R.C.; Robinson, S.; Critchley, M.

    1994-01-01

    To establish the normal pattern of postoperative tracer uptake we performed 73 99m technetium methylene disphosphonate scans following primary Charnley hip replacements for arthrosis in 68 patients without clinical, hematological and radiographic complications. The patients were divided into 7 subgroups according to the period, 6-24 months, between surgery and scan. There were 10-12 patients in each subgroup. A high-resolution gamma camera with a large filed of view was used. Ratios of uptake in each of 10 peri-prosthetic zones to normal bone were calculated. Femoral uptake was found to decrease in linear fashion from 6 to 12 months after surgery. Thereafter the uptake remained unaltered at levels nearly twice the normal ones in the greater trochanter and nearly 1.5 times in the lesser trochanter, returning to almost normal levels in other zones. Acetabular uptake remained elevated throughout. (au) (20 refs.)

  12. Quantitative bone scanning after asymptomatic Charnley arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Mullaji, A.B. (University Department of Orthopedic and Accident Surgery, Royal Liverpool University Hospital, Lierpool (United Kingdom)); Tood, R.C. (Department of Orthopedics, Black Notley Hospital, Braintree (United Kingdom)); Robinson, S. (Department of MedicaL Physics, Colchester General Hospital, Colchester (United Kingdom)); Critchley, M. (Department of Nuclear Medicine, Royal Liverpool University Hospital, Liverpool (United Kingdom))

    1994-06-01

    To establish the normal pattern of postoperative tracer uptake we performed 73 [sup 99m]technetium methylene disphosphonate scans following primary Charnley hip replacements for arthrosis in 68 patients without clinical, hematological and radiographic complications. The patients were divided into 7 subgroups according to the period, 6-24 months, between surgery and scan. There were 10-12 patients in each subgroup. A high-resolution gamma camera with a large filed of view was used. Ratios of uptake in each of 10 peri-prosthetic zones to normal bone were calculated. Femoral uptake was found to decrease in linear fashion from 6 to 12 months after surgery. Thereafter the uptake remained unaltered at levels nearly twice the normal ones in the greater trochanter and nearly 1.5 times in the lesser trochanter, returning to almost normal levels in other zones. Acetabular uptake remained elevated throughout. (au) (20 refs.).

  13. Technetium cyanide chemistry: synthesis and characterization of technetium(III) and -(V) cyanide complexes

    International Nuclear Information System (INIS)

    Trop, H.S.; Jones, A.G.; Davison, A.

    1980-01-01

    Several new technetium cyanide complexes have been prepared and characterized. The reaction of ammonium hexaiodotechnetate(IV) with potassium cyanide in refluxing aqueous methanol under nitrogen yields potassium heptacyanotechnetate(III) dihydrate, K 4 Tc(CN) 7 .2H 2 O (1). Infrared and Raman measurements indicate that 1 has a pentagonal bipyramidal structure (D/sub 5h/) in both solid and solution. Aqueous solutions of 1 are air sensitive, decomposing to potassium oxopentacyanotechnetate(V) tetrahydrate, K 2 TcO(CN) 5 .4H 2 O (2). This species can also be prepared from the reaction of TcO 2 .xH 2 O with hot aqueous potassium cyanide solutions. Hydrolysis of 2 in water yields potassium trans-dioxo-tetracyanotechnetate(V), K 3 TcO 2 (CN) 4 (3). Preparation of 3 can also be achieved from the treatment of [TcO 2 (Py) 4 ]ClO 4 .2H 2 O with aqueous potassium cyanide. Infrared and Raman measurements on 3 are consistent with the proposed trans-dioxo (D/sub 4h/) structure. Reaction of the oxotetrachlorotechnetate(V) anion, TcOCl 4 , with potassium cyanide in methanol produces trans-oxomethoxytetracyanotechnetate(V). [TcO(OMe)(CN) 4 ] (4). The full details of the synthesis and characterization of these interesting technetium(III) and -(V) complexes, as well as observations on the infrared and Raman spectra of trans-dioxo metal complexes and the hydrolysis of species 2, are presented

  14. Fluoridonitrosyl complexes of technetium(I) and technetium(II). Synthesis, characterization, reactions, and DFT calculations.

    Science.gov (United States)

    Balasekaran, Samundeeswari Mariappan; Spandl, Johann; Hagenbach, Adelheid; Köhler, Klaus; Drees, Markus; Abram, Ulrich

    2014-05-19

    A mixture of [Tc(NO)F5](2-) and [Tc(NO)(NH3)4F](+) is formed during the reaction of pertechnetate with acetohydroxamic acid (Haha) in aqueous HF. The blue pentafluoridonitrosyltechnetate(II) has been isolated in crystalline form as potassium and rubidium salts, while the orange-red ammine complex crystallizes as bifluoride or PF6(-) salts. Reactions of [Tc(NO)F5](2-) salts with HCl give the corresponding [Tc(NO)Cl4/5](-/2-) complexes, while reflux in neat pyridine (py) results in the formation of the technetium(I) cation [Tc(NO)(py)4F](+), which can be crystallized as hexafluoridophosphate. The same compound can be synthesized directly from pertechnetate, Haha, HF, and py or by a ligand-exchange procedure starting from [Tc(NO)(NH3)4F](HF2). The technetium(I) cation [Tc(NO)(NH3)4F](+) can be oxidized electrochemically or by the reaction with Ce(SO4)2 to give the corresponding Tc(II) compound [Tc(NO)(NH3)4F](2+). The fluorido ligand in [Tc(NO)(NH3)4F](+) can be replaced by CF3COO(-), leaving the "[Tc(NO)(NH3)4](2+) core" untouched. The experimental results are confirmed by density functional theory calculations on [Tc(NO)F5](2-), [Tc(NO)(py)4F](+), [Tc(NO)(NH3)4F](+), and [Tc(NO)(NH3)4F](2+).

  15. Adsorption of technetium-99m tetrofosmin and technetium-99m furifosmin on plastic syringes

    International Nuclear Information System (INIS)

    Bartosch, R.; Granegger, S.; Sinzinger, H.

    1998-01-01

    Some groups have reported that adsorption of radiopharmaceuticals on disposable plastic syringes can reach levels of almost 50%. This high loss of radioactivity stimulated us to carry out similar studies. Our measurements were done in combination with patient studies. Therefore, we used 2-ml syringes, all of the same brand. The radioactivity in the syringe was measured immediately before and after injection. a total of 500-600 MBq technetium-99m labelled tetrofosmin or technetium-99m furifosmin was administered to 48 patients using four different injection techniques (n = 6 for each technique with each tracer): with needles, 1 min blood incubation at 22 C, 10 or 30 min after preparation of the tracer; with butterflies, 1 min blood incubation at 22 C, 10 or 30 min after preparation of the tracer. Neither in syringes nor in needles or butterflies did more than 7% of the initial radioactivity remain. The entire residual activity in syringe plus needle or syringe plus butterfly together never exceeded the 9% limit. Furthermore, in a pilot study we measured the remaining radioactivity in the vial; here, too, we found no more than 14% of total radioactivity. These findings indicate that total retention of radioactivity during elution and application of 99m Tc-tetrofosmin and 99m Tc-furifosmin with material used in our setting does not approach relevant amounts. (orig.)

  16. Use of pyrophosphate-/sup 99m/Tc in diagnosis of malignant tumors of bones

    Energy Technology Data Exchange (ETDEWEB)

    Kasatkin, Yu N; Purizhanskii, I I; Survila, Z P; Agranat, V Z; Korsunskii, V N

    1976-10-01

    Pyrophosphate-/sup 99m/Tc was administered intravenously in a dose of 0.05 to 0.08 mCi per 1 kg body weight of the patient. Studies were made after 4, 6, and 24 hours with fixed and movable detectors. During investigations a gamma-chamber magnetic memory and a 4096-channel analyzer were also used. A quantitative processing of the material was made. The authors determined distribution of the preparation in normal and pathological bone tissue. A total of 142 patients with tumors of the bone tissue were examined; 858 radioisotope measurements were made. An analysis of accumulation of pyrophosphate-/sup 99m/Tc in primary osteogenic tumors in systemic affections of the bones and bone metastases was made. There is a relation between the concentration of the radiopharmaceutical preparation and the morphological structure of the tumor. Reduction in the accumulation of the radioactive indicator took place after radiation and medicinal effect, this made it possible to judge the regression of the tumor.

  17. Comparison between hemosiderin and Technetium-99 in sentinel lymph node biopsy in human breast cancer

    International Nuclear Information System (INIS)

    Vasques, Paulo Henrique Diogenes; Aquino, Ranniere Gurgel Furtado de; Pinheiro, Luiz Gonzaga Porto; Torres, Roberto Vitor Almeida; Bezerra, Jose Lucas Martins; Brasileiro, Luis Porto

    2015-01-01

    Purpose: To assess the safety and potential equivalence of the use of hemosiderin compared to the Technetium-99 in sentinel lymph node biopsy in human breast cancer. Methods: Non-random sample of 14 volunteer women diagnosed with breast cancer with primary tumors (T1/T2) and clinically tumor-free axilla were submitted to the identification of sentinel lymph node using hemosiderin obtained from autologous blood injected in the periareolar region 24h before surgery on an outpatient basis. Patients received preoperative subareolar intradermal injection of Technetium-99 in the immediate preoperative period. Patients were submitted to sentinel lymph node biopsy, with incision in the axillary fold guided by Gamma-Probe, dissection by planes until the identification of the point of maximum uptake of Technetium-99, identifying the marked nodes and their colors. All surgical specimens were sent for pathological and immunohistochemical study. Results: The results showed no evidence of side effects and/or allergic and non-allergic reactions in patients submitted to SLNB with hemosiderin. The SLN identification rate per patient was 100%. SLNB identification rate per patient with hemosiderin was the same as that of Technetium, with a concordance rate of 100% between the methods. Conclusion: Hemosiderin is a safe dye that is equivalent to Technetium in breast sentinel lymph node biopsy. (author)

  18. Comparison between hemosiderin and Technetium-99 in sentinel lymph node biopsy in human breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Vasques, Paulo Henrique Diogenes; Aquino, Ranniere Gurgel Furtado de; Pinheiro, Luiz Gonzaga Porto, E-mail: luizgporto@uol.com.br [Universidade Federal do Ceara (UFC), Fortaleza, CE (Brazil). Departamento de Cirurgia; Alves, Mayara Maia [Rede Nordeste de Biotecnologia (RENORBIO/UFC), Fortaleza, CE (Brazil); Torres, Roberto Vitor Almeida; Bezerra, Jose Lucas Martins [Universidade Federal do Ceara (UFC), Fortaleza, CE (Brazil). Faculdade de Medicina; Brasileiro, Luis Porto [Faculdades INTA, Sobral, CE (Brazil). Faculdade de Medicina

    2015-11-15

    Purpose: To assess the safety and potential equivalence of the use of hemosiderin compared to the Technetium-99 in sentinel lymph node biopsy in human breast cancer. Methods: Non-random sample of 14 volunteer women diagnosed with breast cancer with primary tumors (T1/T2) and clinically tumor-free axilla were submitted to the identification of sentinel lymph node using hemosiderin obtained from autologous blood injected in the periareolar region 24h before surgery on an outpatient basis. Patients received preoperative subareolar intradermal injection of Technetium-99 in the immediate preoperative period. Patients were submitted to sentinel lymph node biopsy, with incision in the axillary fold guided by Gamma-Probe, dissection by planes until the identification of the point of maximum uptake of Technetium-99, identifying the marked nodes and their colors. All surgical specimens were sent for pathological and immunohistochemical study. Results: The results showed no evidence of side effects and/or allergic and non-allergic reactions in patients submitted to SLNB with hemosiderin. The SLN identification rate per patient was 100%. SLNB identification rate per patient with hemosiderin was the same as that of Technetium, with a concordance rate of 100% between the methods. Conclusion: Hemosiderin is a safe dye that is equivalent to Technetium in breast sentinel lymph node biopsy. (author)

  19. The peculiarities of electrochemical deposition and morphology of ZnMn alloy coatings obtained from pyrophosphate electrolyte

    Directory of Open Access Journals (Sweden)

    Bučko Mihael M.

    2011-01-01

    Full Text Available The first successful attempt to electrodeposit ZnMn alloy coatings from alkaline bath was made only a few years ago. In this kind of solution, potassium pyrophosphate (K4P2O7 serves both as a complexing agent and as the basic electrolyte. The aim of this work was to study the electrodeposition process and properties of ZnMn alloy coatings deposited from pyrophosphate solution, with a new kind of alkaline pyrophosphate bath. Namely, chloride salts were used as the source of metal ions and ascorbic acid was used as reducing agent. The composition of the plating solution was as follows: 1 mol dm-3 K4P2O7 + 0.017 mol dm-3 ascorbic acid + 0.05 mol dm-3 ZnCl2 + 0.05 mol dm-3 MnCl2•4H2O. Cathodic processes during the alloy electrodeposition were investigated using linear voltammetry. The influence of addition of small amounts of ascorbic acid on the cathodic processes was established. It was shown that this substance inhibits hydrogen evolution and increases the current efficiency of alloy deposition. The current efficiency in the plating bath examined was in the range of 25 and 30%, which was quite higher as compared to the results reported in the literature for electrodeposition of ZnMn alloy from pyrophosphate bath. Electrodeposition of ZnMn alloys was performed galvanostatically on steel panels, at current densities of 20120 mA cm-2. The coatings with the best appearance were obtained at current densities between 30 and 80 mA cm-2. The surface morphology studies, based on atomic force microscopy measurements, showed that morphology of the deposits is highly influenced by deposition current density. ZnMn coating deposited at 30 mA cm-2 was more compact and possessed more homogeneous structure (more uniform agglomeration size than the coating deposited at 80 mA cm-2. Such dependence of morphology on the current density could be explained by the high rate of hydrogen evolution reaction during the electrodeposition process.

  20. Non-pertechnetate Technetium Sensor Research and Development

    Energy Technology Data Exchange (ETDEWEB)

    Bryan, Samuel A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rapko, Brian M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Branch, Shirmir D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Univ. of Cincinnati, OH (United States); Lines, Amanda M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Heineman, William R. [Univ. of Cincinnati, OH (United States); Soderquist, Chuck Z. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-03-24

    Several significant uncertainties remain regarding the understanding and modeling of the fate and speciation of technicium-99 (99Tc) in Hanford waste tanks, glass, and low-temperature waste forms. A significant (2% to 25%) fraction of the 99Tc in the water-soluble portion of the tank waste may be present as one or more non pertechnetate species that have not been identified and to date, cannot be effectively separated from the wastes. This task will provide a sensor specifically tuned to detect the Tc(I)-carbonyl species believed to constitute the main fraction of the non-pertechnetate form of technetium. By direct measurement of the non-pertechnetate species, such a sensor will help reduce the uncertainties in the modeling of the fate and speciation of 99Tc in Hanford tanks and waste forms. This report summarizes work performed in FY2016 that was sponsored by the Department of Energy’s Office of Environmental Management and demonstrates the protocol for using fluorescent Tc(I)-tricarbonyl complex as a means to detect the non-pertechnetate species within tank waste solutions. The protocol was optimized with respect to ligand concentration, solvent choice, reaction temperature and time. This work culminated in the quantitation of Tc(I)-tricarbonyl within a waste simulant, using a standard addition method for measurement. This report also summarizes the synthesis and high-yield preparation of the low-valence technetium species, [Tc(CO)3(H2O)3]+, which will be used as the technetium standard material for the demonstration of the non-pertechnetate species in actual wastes.

  1. Method for radiolabeling proteins with technetium-99m

    International Nuclear Information System (INIS)

    Crockford, D.R.; Rhodes, B.A.

    1984-01-01

    In accordance with this invention, a substrate to be radiolabeled with technetium-99m is admixed with a buffered stannous chloride composition having a pH between about 4.5 and about 8.5 wherein the stannous chloride is produced from a non-oxidized tin source, the buffered stannous chloride is purged of oxygen and the buffer comprises a mixture of alkali metal biphthalate and an alkali metal tartrate. Alternatively, the buffer may include alkali metal borate or gentisate. The stannous chloride solution is admixed with the buffer and the resultant mixture is neutralized with sodium hydroxide. The neutralized solution then is admixed with the substrate eventually to be radiolabeled with technetium-99m. This solution is allowed to incubate for several hours (usually over 15 hours) in the absence of oxygen and at room temperature

  2. Physics of the missing atoms: technetium and promethium

    International Nuclear Information System (INIS)

    Aspden, H.

    1987-01-01

    Technetium (Z = 43) and promethium (Z = 61) are by far the least abundant of all atoms below the radioactive elements (Z = 84 onwards). Their scarcity confirms theoretical predictions emerging from a theory of the photon derived from synchronous lattice electrodynamics. This theory has given precise theoretical values for the fine-structure constant and the constant of gravitation G and is now shown in this paper to indicate resonant interactions between the vacuum lattice oscillations and technetium and promethium. In the case of promethium there is strong reason for believing that this atom can assume supergravitational or antigravitational properties, accounting for its scarcity. This paper not only adds support to the earlier theoretical work on the photon and gravitation, but suggests a research route that might lead to new technology based on controlled interactions with gravity fields

  3. Pyrophosphate heart scintigram in children with progressive muscular dystrophy

    Energy Technology Data Exchange (ETDEWEB)

    Duska, F; Nesvadba, Z; Zdansky, P; Novak, J; Kubicek, J; Kafka, P; Vizda, J; Mazurova, Y

    1984-08-01

    A pyrophosphate heart scintigram was obtained in 16 boys with progressive muscular dystrophy Duchenne. All of them showed pathological ECG findings and high plasma levels of CK, AST, ALT and LD. In 4 patients the scintigram was distinctly positive and in further 3 it reached borderline values. The remaining 9 boys had normal scintigraphic findings. Those with a positive heart scintigram had very high plasma levels of the enzymes under study which was suggestive of current progression of the disease. There was, however, no relation between heart scintigraphy and the affliction of the skeletal muscles expressed by means of an index.

  4. Extraosseous uptake of technetium-99m methylene diphosphonate by an acute territorial cerebral infarct in a classical biodistribution pattern

    International Nuclear Information System (INIS)

    Kannivelu, Anbalagan; Padhy, Ajit Kumar; Srinivasan, Sivasubramanian; Ali, Syed Zama

    2013-01-01

    Technetium-99m methylene diphosphonate scintigraphy is usually performed to assess bone lesions, especially skeletal metastases in patients with a history of malignancy. However, it is important to recognize some specific conditions with a unique pattern of tracer uptake, especially in extraosseous locations as they are not related to primary neoplasm or metastases. Diagnosing such unusual presentation is essential as it significantly influences the clinical management. This case report describes an unusual presentation detected in a bone scan of an elderly female patient, who was a treated case of breast cancer and was referred for a bone scan to rule out bone metastases. Incidentally, a large acute territorial cerebral infarct was diagnosed, which was later confirmed by magnetic resonance imaging on diffusion-weighted images. Diagnosis of the typical presentation and timely management saved the patient life. (author)

  5. Cardiac amyloidosis detection with pyrophosphate-99mTc scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Souza, D.S.F.; Ichiki, W.A.; Coura Filho, G.B.; Izaki, M.; Giorgi, M.C.P.; Soares Junior, J; Meneghetti, J.C. [Universidade de Sao Paulo (FM/USP), SP (Brazil). Fac. de Medicina. Instituto do Coracao. Servico de Medicina Nuclear e Imagem Molecular

    2008-07-01

    Full text: Introduction: Amyloidosis is a rare disease, characterized by extracellular deposition of insoluble amyloid fibrils in organs and tissues. It may affect virtually any system, preferably heart, kidneys and liver. The cardiac involvement produces a spectrum of clinical features, usually with progressive dysfunction. Early diagnosis is important for institution of appropriate therapy. Case report: Male patient, 75 years old, with diagnosed congestive heart failure functional class III and Mobitz II second-degree atrial-ventricular block, was hospitalized for implantation of definitive cardiac pacemaker. Patient mentioned history of worsening effort dyspnoea over a one-month period, progressing to minimum effort, orthopnea, paroxysmal nocturnal dyspnoea and paroxysms of dry cough, and swelling of lower limbs. Echocardiography showed diffuse hypertrophy of left ventricle (LV), with systolic dysfunction due to diffuse hypokinesia and hyperrefringent aspect in the septum. It was questioned a cardiac infiltrating process. Cardiac amyloidosis was considered as a diagnostic hypothesis. The patient underwent a pyrophosphate-{sup 99m}Tc scintigraphy, which showed abnormal tracer uptake in the heart projection, with diffuse pattern on the left ventricle walls, compatible with the clinical suspicion cardiac amyloidosis, which was later confirmed by endomyocardial biopsy. Discussion: In this case report, the patient had clinical and other auxiliary examinations, such as electrocardiography and Doppler echocardiography, compatible with cardiac amyloidosis, which led to implementation with pyrophosphate-{sup 99m}Tc scintigraphy and later endomyocardial biopsy. Cardiac amyloidosis occurs in about half the cases of primary amyloidosis (AL) and is rare in secondary amyloidosis (AA). Its clinical presentation is polymorphic and it can be classified into four distinctive types: restrictive cardiomyopathy, systolic dysfunction, postural hypotension and conduction disorders

  6. Cardiac amyloidosis detection with pyrophosphate-99mTc scintigraphy

    International Nuclear Information System (INIS)

    Souza, D.S.F.; Ichiki, W.A.; Coura Filho, G.B.; Izaki, M.; Giorgi, M.C.P.; Soares Junior, J; Meneghetti, J.C.

    2008-01-01

    Full text: Introduction: Amyloidosis is a rare disease, characterized by extracellular deposition of insoluble amyloid fibrils in organs and tissues. It may affect virtually any system, preferably heart, kidneys and liver. The cardiac involvement produces a spectrum of clinical features, usually with progressive dysfunction. Early diagnosis is important for institution of appropriate therapy. Case report: Male patient, 75 years old, with diagnosed congestive heart failure functional class III and Mobitz II second-degree atrial-ventricular block, was hospitalized for implantation of definitive cardiac pacemaker. Patient mentioned history of worsening effort dyspnoea over a one-month period, progressing to minimum effort, orthopnea, paroxysmal nocturnal dyspnoea and paroxysms of dry cough, and swelling of lower limbs. Echocardiography showed diffuse hypertrophy of left ventricle (LV), with systolic dysfunction due to diffuse hypokinesia and hyperrefringent aspect in the septum. It was questioned a cardiac infiltrating process. Cardiac amyloidosis was considered as a diagnostic hypothesis. The patient underwent a pyrophosphate- 99m Tc scintigraphy, which showed abnormal tracer uptake in the heart projection, with diffuse pattern on the left ventricle walls, compatible with the clinical suspicion cardiac amyloidosis, which was later confirmed by endomyocardial biopsy. Discussion: In this case report, the patient had clinical and other auxiliary examinations, such as electrocardiography and Doppler echocardiography, compatible with cardiac amyloidosis, which led to implementation with pyrophosphate- 99m Tc scintigraphy and later endomyocardial biopsy. Cardiac amyloidosis occurs in about half the cases of primary amyloidosis (AL) and is rare in secondary amyloidosis (AA). Its clinical presentation is polymorphic and it can be classified into four distinctive types: restrictive cardiomyopathy, systolic dysfunction, postural hypotension and conduction disorders. Cardiac

  7. Preparation and quality control of technetium-99m radiopharmaceuticals

    International Nuclear Information System (INIS)

    Samuels, D.L.

    1978-11-01

    Appropriate procedures for the production and quality control of technetium-99m based radiopharmaceuticals in hospital radiopharmacy consistent with the recently published Australian Code of Good Manufacturing Practice are discussed

  8. OSTEOPOROSIS IN CALCIUM PYROPHOSPHATE CRYSTAL DEPOSITION DISEASE

    Directory of Open Access Journals (Sweden)

    S A Vladimirov

    2013-01-01

    Full Text Available Objective: to study the incidence of osteoporosis (OP in patients with calcium pyrophosphate crystal deposition disease (CPCDD. Subjects and methods. Eighty patients with CPCDD were examined. Bone mineral density (BMD of the forearm, lumbar spine, and femoral neck was determined by dual-energy X-ray absorptiometry. Laboratory diagnosis involved determination of the blood levels of C-reactive protein, parathyroid hormone, calcium, magnesium, and phosphorus and the daily urinary excretion of calcium and phosphates. Results. The patients with OP were significantly older than those with normal BMD and osteopenia. Forearm bones were the most common isolated location of OP and osteopenia. Injuries in the history, traumatic fractures, and the intake of diuretics were somewhat more common in the patients diagnosed with OP. The incidence of hyperparathyroidism did not differ significantly in the groups.

  9. Technetium-99m pertechnetate - a tracer for radiolabelling antibody for inflammation detection

    International Nuclear Information System (INIS)

    Shaharuddin Mohd; Wan Hamirul Bahrin Wan Kamal; Shahrin A Hamid; Ang Woan Tze; Rosnani Hashim

    1999-01-01

    The polyclonal antibody, Human Immunoglobulin G (HlgG) was reduced by using 2-mercaptoethanol with molar ratio of 1000:1 (i.e. mercaptoethanol:antibody). The reduction of the antibody, was carried out for 30 minutes at room temperature. The reduced antibody was purified by using Sephadex G-25 fine column. The antibody kit for the detection of inflammation was prepared aseptically in Class 1 Laminar Flow cabinet. The kit passed the sterility test. Upon reconstitution of the antibody kit with sodium pertechnetate-99m ( 99m Tc) solution, the labelling efficiency obtained was more than 95%. This preparation was stable up to 24-hour stored at room temperature. Gamma camera scans showed the accumulation of technetium-99m labelled antibody ( 99m Tc-HIgG) at the turpentine-induced inflammation of female Sprague-Dawley rats. This indicated the possibility of using 99m Tc-HIgG for inflammation detection. (author)

  10. Characterization of technetium(vII) reduction by cell suspensions of thermophilic bacteria and archaea.

    Science.gov (United States)

    Chernyh, Nikolay A; Gavrilov, Sergei N; Sorokin, Vladimir V; German, Konstantin E; Sergeant, Claire; Simonoff, Monique; Robb, Frank; Slobodkin, Alexander I

    2007-08-01

    Washed cell suspensions of the anaerobic hyperthermophilic archaea Thermococcus pacificus and Thermoproteus uzoniensis and the anaerobic thermophilic gram-positive bacteria Thermoterrabacterium ferrireducens and Tepidibacter thalassicus reduced technetium [(99)Tc(VII)], supplied as soluble pertechnetate with molecular hydrogen as an electron donor, forming highly insoluble Tc(IV)-containing grayish-black precipitate. Apart from molecular hydrogen, T. ferrireducens reduced Tc(VII) with lactate, glycerol, and yeast extract as electron donors, and T. thalassicus reduced it with peptone. Scanning electron microscopy and X-ray microanalysis of cell suspensions of T. ferrireducens showed the presence of Tc-containing particles attached to the surfaces of non-lysed cells. This is the first report on the reduction in Tc(VII) by thermophilic microorganisms of the domain Bacteria and by archaea of the phylum Euryarchaeota.

  11. Heterovalent Zr4+ - Cu2+ substitution in zirkonium pyrophosphate: From theoretical models to synthesis and utilization

    Czech Academy of Sciences Publication Activity Database

    Gorodylova, N.; Šulcová, P.; Bosacka, M.; Filipek, E.; Vlček, Milan

    2015-01-01

    Roč. 35, č. 15 (2015), s. 4293-4305 ISSN 0955-2219 Institutional support: RVO:61389013 Keywords : zirconium pyrophosphate * cooper phosphates * thermal stability Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 2.933, year: 2015

  12. LABORATORY REPORT ON THE REDUCTION AND STABILIZATION (IMMOBILIZATION) OF PERTECHNETATE TO TECHNETIUM DIOXIDE USING TIN(II)APATITE

    Energy Technology Data Exchange (ETDEWEB)

    DUNCAN JB; HAGERTY K; MOORE WP; RHODES RN; JOHNSON JM; MOORE RC

    2012-06-01

    This effort is part of the technetium management initiative and provides data for the handling and disposition of technetium. To that end, the objective of this effort was to challenge tin(II)apatite (Sn(II)apatite) against double-shell tank 241-AN-105 simulant spiked with pertechnetate (TcO{sub 4}{sup -}). The Sn(II)apatite used in this effort was synthesized on site using a recipe developed at and provided by Sandia National Laboratories; the synthesis provides a high quality product while requiring minimal laboratory effort. The Sn(II)apatite reduces pertechnetate from the mobile +7 oxidation state to the non-mobile +4 oxidation state. It also sequesters the technetium and does not allow for re-oxidization to the mo bile +7 state under acidic or oxygenated conditions within the tested period oftime (6 weeks). Previous work (RPP-RPT-39195, Assessment of Technetium Leachability in Cement-Stabilized Basin 43 Groundwater Brine) indicated that the Sn(II)apatite can achieve an ANSI leachability index in Cast Stone of 12.8. The technetium distribution coefficient for Sn(II)apatite exhibits a direct correlation with the pH of the contaminated media. Table A shows Sn(II)apatite distribution coefficients as a function of pH. The asterisked numbers indicate that the lower detection limit of the analytical instrument was used to calculate the distribution coefficient as the concentration of technetium left in solution was less than the detection limit. The loaded sample (200 mg of Sn(II)apatite loaded with O.311 mg of Tc-99) was subjected to different molarities of nitric acid to determine if the Sn(II)apatite would release the sequestered technetium. The acid was allowed to contact for 1 minute with gentle shaking ('1st wash'); the aqueous solution was then filtered, and the filtrate was analyzed for Tc-99. Table B shows the results ofthe nitric acid exposure. Another portion of acid was added, shaken for a minute, and filtered ('2nd wash'). The

  13. Quantitative radiocardiography by single-probe counting using sup(99m)technetium albumin

    International Nuclear Information System (INIS)

    Man in 't Veld, A.J.; Wenting, G.J.; Verhoeven, R.P.; Schalekamp, M.A.D.H.

    1978-01-01

    Quantitative radiocardiography with sup(99m)Technetium albumin, using a single probe for percordial counting of radioactivity is a non-invasive technique to measure cardiac output. sup(99m)Technetium pertechnetate is bound to albumin by electrolytic complexation. Preparations of sup(99m)Technetium albumin showed small percentages of free radioactivity. In-vivo stability of the complex was confirmed by comparison with distribution volumes of 131 Iodine albumin and sup(113m)Indium transferrin. The isotope dilution cardiac output technique was validated by comparison with a classical indocyanine green dilution method. Results obtained by peripheral intravenous injection of the isotope were not different from those after intracardiac injection. Exact localization of the collimator over the heart was not critical. Duplicate measurements showed good reproducibility. Examples of serial measurements in patients with hyperthyroidism, primary aldosteronism and essential hypertinsion are given. The method is reliable, accurate and safe and causes no discomfort to the patient. (C.F.)

  14. ASSESSMENT OF TECHNETIUM LEACHABILITY IN CEMENT STABILIZED BASIN 43 GROUNDWATER BRINE

    International Nuclear Information System (INIS)

    COOKE GA; DUNCAN JB; LOCKREM LL

    2008-01-01

    This report is an initial report on the laboratory effort executed under RPP-PLAN-33338, Test Plan for the Assessment of Technetium Leachability in Cement-Stabilized Basin 43 Groundwater Brine. This report delineates preliminary data obtained under subcontract 21065, release 30, from the RJ Lee Group, Inc., Center for Laboratory Sciences. The report is predicated on CLS RPT-816, Draft Report: Assessment of Technetium Leachability in Cement Stabilized Basin 43 Groundwater Brine. This document will be revised on receipt of the final RJ Lee Group, Inc., Center for Laboratory Sciences report, which will contain data subjected to quality control and quality assurance criteria

  15. Chemistry of rhenium and technetium. II. Schiff base complexes with polyfunctional amino acids

    International Nuclear Information System (INIS)

    Du Preez, J.G.H.; Gerber, T.I.A.; Fourie, P.J.; Van Wyk, A.J.

    1984-01-01

    Amino acid Schiff base technetium(V) complexes of salicylaldehyde with l-cysteine, l-serine, l-histodine, l-threonine, l-glutamic acid and l-tryptophan have been preapred by direct reaction and by constituent combination. The amino acid part of the ligands coordinates to the technetium through the carboxylate group, while the other available functional group of the amino acids plays a more minor role as blocking group or in intramolecular bonding. 3 tables

  16. Adsorption of technetium-99m tetrofosmin and technetium-99m furifosmin on plastic syringes

    Energy Technology Data Exchange (ETDEWEB)

    Bartosch, R.; Granegger, S.; Sinzinger, H. [Department of Nuclear Medicine, University of Vienna (Austria)

    1998-09-01

    Some groups have reported that adsorption of radiopharmaceuticals on disposable plastic syringes can reach levels of almost 50%. This high loss of radioactivity stimulated us to carry out similar studies. Our measurements were done in combination with patient studies. Therefore, we used 2-ml syringes, all of the same brand. The radioactivity in the syringe was measured immediately before and after injection. a total of 500-600 MBq technetium-99m labelled tetrofosmin or technetium-99m furifosmin was administered to 48 patients using four different injection techniques (n = 6 for each technique with each tracer): with needles, 1 min blood incubation at 22 C, 10 or 30 min after preparation of the tracer; with butterflies, 1 min blood incubation at 22 C, 10 or 30 min after preparation of the tracer. Neither in syringes nor in needles or butterflies did more than 7% of the initial radioactivity remain. The entire residual activity in syringe plus needle or syringe plus butterfly together never exceeded the 9% limit. Furthermore, in a pilot study we measured the remaining radioactivity in the vial; here, too, we found no more than 14% of total radioactivity. These findings indicate that total retention of radioactivity during elution and application of {sup 99m}Tc-tetrofosmin and {sup 99m}Tc-furifosmin with material used in our setting does not approach relevant amounts. (orig.) With 4 figs., 1 tab., 7 refs.

  17. Contributions to the coordination chemistry of technetium

    International Nuclear Information System (INIS)

    Lorenz, B.

    1989-08-01

    New types of technetium complexes were synthesized and analyzed by IR-, 1 H- and 99 Tc nmr as well as EPR spectra. They were tested for their potential catalytic activity in special organic reactions and their relevance to catalytic reactions, for example as intermediate compounds, is discussed in depth. 317 refs., 20 figs. (BBR) [de

  18. Nature`s uncommon elements: Plutonium and technetium

    Energy Technology Data Exchange (ETDEWEB)

    Curtis, D.; Fabryka-Martin, J.; Dixon, P. [Los Alamos National Lab., NM (United States). Chemical Science and Technology Div.; Cramer, J. [Atomic Energy of Canada Ltd., Pinawa, Manitoba (Canada). Whiteshell Lab.

    1998-01-06

    The authors have taken advantage of the extremely sensitive method of thermal ionization mass spectrometry to measure technetium and plutonium concentrations in sample masses that are smaller by as much as three orders of magnitude than those used in the early research efforts. The work reported in this paper extends the understanding of the geochemistry of plutonium and technetium by developing detailed descriptions of their associations in well characterized geologic samples, and by using modern neutron-transport modeling tools to better interpret the meaning of the results. Analyses were conducted on samples from three uranium ore deposits selected for their contrasting geochemical environments. The Cigar Lake deposit is an unweathered, unaltered primary ore in a reducing environment which is expected to closely approximate a system that is closed with respect to uranium and its products. The Koongarra deposit is a shallow system, both altered and weathered, subject to active ground water flow. Finally, a sample from the Beaverlodge deposit is included because it is a commercially-available uranium ore standard that allows demonstration of the precision of the analytical results.

  19. Fundamental chemistry, characterization, and separation of technetium complexes in Hanford waste. 1998 annual progress report

    International Nuclear Information System (INIS)

    Ashley, K.R.; Blanchard, D.L. Jr.; Schroeder, N.C.

    1998-01-01

    'The ultimate goal of this proposal is to separate technetium from Hanford tank waste. The recent work has shown that a large portion of the technetium is not pertechnetate (TcO 4 - ) and is not easily oxidized. This has serious repercussions for technetium partitioning schemes because they are designed to separate this chemical form. Rational attempts to oxidize these species to TcO 4 - for processing or to separate the non-pertechnetate species themselves would be facilitated by knowing the identity of these complexes and understanding their fundamental chemistry. Tank characterization work has not yet identified any of the non-pertechnetate species. However, based on the types of ligands available and the redox conditions in the tank, a reasonable speculation can be made about the types of species that may be present. Thus, this proposal will synthesize and characterize the relevant model complexes of Tc(III), Tc(IV), and Tc(V) that may have formed under tank waste conditions. Once synthesized, these complexes will be used as standards for developing and characterizing the non-pertechnetate species in actual waste using instrumental techniques such as capillary electrophoresis electrospray mass spectrometry (CE-MS), x-ray absorbance spectroscopy (EXAFS and XANES), and multi-nuclear NMR (including 99 Tc NMR). The authors study the redox chemistry of the technetium complexes so that more efficient and selective oxidative methods can be used to bring these species to TcO 4 - for processing purposes. They will also study their ligand substitution chemistry which could be used to develop separation methods for non-pertechnetate species. Understanding the fundamental chemistry of these technetium complexes will enable technetium to be efficiently removed from the Hanford tank waste and help DOE to fulfill its remediation mission. This report summarizes the first 8 months of a 3-year project.'

  20. The origins of Technetium in the environment

    International Nuclear Information System (INIS)

    Scoppa, P.

    1986-01-01

    The origins of Technetium in the environment are briefly illustrated, taking into account its main sources represented by same plants of nuclear fuel cycle and by fallout fallowing nuclear explosion in atmosphere. An evaluation is also made of the TC-99 quantitees deriving from the production of nuclear power present in radioactive wastes before their final disposal

  1. Physical chemical quality control of the molybdenum technetium generator

    International Nuclear Information System (INIS)

    Olive, E.; Cruz, J.; Isaac, M.; Gamboa, R.; D'Alessandro, K.; Desdin, L.F.

    1995-01-01

    Comparative operational procedure imported molybdenum technetium generators have been made. Procedures for determination of chemical, radiochemical and radionuclidic purities that may be applied in Hospital's laboratories and in the quality control of generators production are developed

  2. Sorption of technetium and its analogue rhenium on bentonite material under aerobic conditions

    International Nuclear Information System (INIS)

    Koudelkova, M.; Vinsova, H.; Konirova, R.; Ernestova, M.; Jedinakova-Krizova, V.; Tereesha, M.

    2003-01-01

    The uptake of technetium on bentonite materials has been studied from the point of view of characterization of long-term radioactive elements behavior in nuclear waste repository. Bentonite R (locality Rokle, Czech Republic) and two types of model groundwater (granitic and bentonite) were selected for the sorption experiments. The aim of our research has been to find out the conditions suitable for the technetium sorption on selected bentonite under oxidizing condition. The sorption experiments with Tc-99 on bentonite have been carried out by batch method. The influence of the addition of different materials (e.g. activated carbon, graphite, Fe 2+ ) with bentonite, the effect of solid: aqueous phase ratio and a pH value on the percentage of technetium uptake and on the K d values were tested. Perrhenate was selected as an analogue of pertechnetate in non-active experiments of capillary electrophoresis (CE) and isotachophoresis (ITP). The percentage of rhenium sorbed on bentonite material was determined from the decrease of perrhenate peak area (CE) and from the shortening of the ITP zone corresponding to perrhenate. Both electromigration methods provided comparable results. The results obtained in this study with non-active material were compared to those of technetium acquired by radiometry and polarography. The 8 days kinetics of the perrhenate and pertechnetate sorption on bentonite was described mathematically with a tendency to predict long-term behavior of studied systems. (authors)

  3. Method of preparation of technetium-99m labelled radio-diagnostic agents and a stable non radio-active carrier

    International Nuclear Information System (INIS)

    1975-01-01

    A method of preparing improved technetium-99m labeled radiodiagnostic agents is described by reducing technetium-99m with stannous tartrate. Such radiodiagnostic agents are useful in scintigraphic examinations of the bone and lung

  4. Determination of technetium-99 in environmental samples: A review

    DEFF Research Database (Denmark)

    Shi, Keliang; Hou, Xiaolin; Roos, Per

    2012-01-01

    Due to the lack of a stable technetium isotope, and the high mobility and long half-life, 99Tc is considered to be one of the most important radionuclides in safety assessment of environmental radioactivity as well as nuclear waste management. 99Tc is also an important tracer for oceanographic...... research due to the high technetium solubility in seawater as TcO4−. A number of analytical methods, using chemical separation combined with radiometric and mass spectrometric measurement techniques, have been developed over the past decades for determination of 99Tc in different environmental samples....... This article summarizes and compares recently reported chemical separation procedures and measurement methods for determination of 99Tc. Due to the extremely low concentration of 99Tc in environmental samples, the sample preparation, pre-concentration, chemical separation and purification for removal...

  5. {8-14C}-Adenine and {1-14C}-isopentenyl pyrophosphate - precursors for root-produced cytokinins in the tomato (Lycopersicon esculentum mill.)

    International Nuclear Information System (INIS)

    Dickinson, J.R.

    1985-01-01

    Following the detection of reasonable levels of biologically active cytokinin-like compounds in one-month-old tomato plants, the possible involvement of {8- 14 C}-adenine and {1- 14 C}-isopentenyl pyrophosphate in the biosynthetic pathway leading to an accumulation of free zeatin derivatives, was studied. Intact tomato plants were used for a time-course study involving the uptake of {8- 14 C}-adenine and the tentative identification of compounds into which the 14 C became incorporated. Using high performance liquid chromatography, radioactive trans-zeatin was identified as being present in the Dowex 50 root extract. The 12-hour time interval was used and the roots of the tomato plants were immersed in a more heavily radiolabelled medium. Modified separation techniques were used to achieve enhanced radioactivity recovery rates. This experiment demonstrated the presence of relatively high levels of tentatively identified radioactive zeatin in the Dowex 50 root and stem extracts. Radioactivity in the aqueous extracts was found not to be contributed by cytokinin nucleotides. A final experiment was carried out using decapitated root systems to determine if the root tissue alone could be implicated in the synthesis of cytokinins. Decapitated tomato root systems were supplied with either {8- 14 C}-adenine or {1- 14 C}-isopentenyl pyrophosphate. The ratio of incorporation of {1- 14 C}-isopentenyl pyrophosphate into identified cytokinins was higher than for {8- 14 C}-adenine. It was concluded that both adenine and isopentenyl pyrophosphate are involved in the biosynthetic pathway leading to an accumulation of free zeatin derivatives in tomato roots

  6. Technetium and neptunium reactions in basalt/groundwater systems

    International Nuclear Information System (INIS)

    Meyer, R.E.; Arnold, W.D.; Kelmers, A.D.; Kessler, J.H.; Clark, R.J.; Johnson, J.S. Jr.; Young, G.C.; Case, F.I.; Westmoreland, C.G.

    1985-01-01

    Sorption isotherms and apparent concentration limits for Tc(VII) and Np(V) for a variety of groundwater/basalt systems were determined using Grande Ronde basalt samples representative of the Hanford Site candidate high-level waste repository. Under oxic redox conditions (air present), little or no sorption of technetium was observed; neptunium exhibited low to moderate sorption ratios. Under anoxic redox conditions (oxygen-free), low to moderate sorption of technetium was often observed, but the extent of sorption was highly dependent upon the groundwater composition and the method of pretreatment (if any) of the basalt. Sorption isotherms for technetium under reducing redox conditions (hydrazine added) indicate an apparent concentration limit of approximately 10 -6 mol/l Tc. No apparent concentration limit was found for neptunium for concentrations in groundwater up to 10 -6 mol/l and 8 x 10 -7 mol/l under oxic and reducing (hydrazine added) redox conditions, respectively. Valence control and valence analysis experiments suggest that the sorption or precipitation of Tc and Np from groundwater in the presence of basalt may result from a heterogeneous reaction occurring on the surface of the basalt. One of the critical factors of this reduction reaction appears to be the accessibility of the reactive ferrous iron component of the basalt. The laboratory simulation of groundwater redox conditions representative of the repository environment through the use of solution phase redox reagents is of questionable validity, and information obtained by such experimental methods may not be defensible for site performance assessment calculations. Anoxic experiments conducted in an argon-filled glove box appear better suited for the laboratory simulation of in situ redox conditions. 15 references, 6 figures

  7. Technetium and neptunium reactions in basalt/groundwater systems

    International Nuclear Information System (INIS)

    Meyer, R.E.; Arnold, W.D.; Kelmers, A.D.; Kessler, J.H.; Clark, R.J.; Johnson, J.S. Jr.; Young, G.C.; Case, F.I.; Westmoreland, C.G.; Florida State Univ., Tallahassee)

    1984-01-01

    Sorption isotherms and apparent concentration limits for Tc(VII) and Np(V) for a variety of groundwater/basalt systems were determined using Grande Ronde basalt samples representative of the Hanford Site candidate high-level waste repository. Under oxic redox conditions (air present), little or no sorption of technetium was observed; neptunium exhibited low to moderate sorption ratios. Under anoxic redox conditions (oxygen-free), low to moderate sorption of technetium was often observed, but the extent of sorption was highly dependent upon the groundwater composition and the method of pretreatment (if any) of the basalt. Sorption isotherms for technetium under reducing redox conditions (hydrazine added) indicate an apparent concentration limit of approximately 10 -6 mol/L Tc. No apparent concentration limit was found for neptunium for concentrations in groundwater up to approx. 10 -6 mol/L and 8 x 10 -7 mol/L under oxic and reducing (hydrazine added) redox conditions, respectively. Valence control and valence analysis experiments suggest that the sorption or precipitation of Tc and Np from groundwater in the presence of basalt may result from a heterogeneous reaction occurring on the surface of the basalt. One of the critical factors of this reduction reaction appears to be the accessibility of the reactive ferrous iron component of the basalt. The laboratory simulation of groundwater redox conditions representative of the repository environment through the use of solution phase redox reagents is of questionable validity, and information obtained by such experimental methods may not be defensible for site performance assessment calculations. Anoxic experiments conducted in an argon-filled glove box appear better suited for the laboratory simulation of in situ redox conditions. 15 refs., 6 tabs

  8. The pyrophosphate heart scintigram in children with progressive muscular dystrophy

    International Nuclear Information System (INIS)

    Duska, F.; Nesvadba, Z.; Zdansky, P.; Novak, J.; Kubicek, J.; Kafka, P.; Vizda, J.; Mazurova, Y.; Karlova Univ., Hradec Kralove; Karlova Univ., Hradec Kralove

    1984-01-01

    A pyrophosphate heart scintigram was obtained in 16 boys with progressive muscular dystrophy Duchenne. All of them showed pathological ECG findings and high plasma levels of CK, AST, ALT and LD. In 4 patients the scintigram was distinctly positive and in further 3 it reached borderline values. The remaining 9 boys had normal scintigraphic findings. Those with a positive heart scintigram had very high plasma levels of the enzymes under study which was suggestive of current progression of the disease. There was, however, no relation between heart scintigraphy and the affliction of the skeletal muscles expressed by means of an index. (orig.) [de

  9. An introduction to technetium-99m generators

    International Nuclear Information System (INIS)

    Abrashkin, S.

    1984-02-01

    The role played by technetium-99m generators in diagnostic medicine, their physical and chemical fundamentals and their main technical characteristics are discussed. This report is intended as a general introduction to a group of reports which summarize the work done on the development and production of the generators, and research on the chemical and physical aspects of the generator systems

  10. Technetium removal: preliminary flowsheet options

    International Nuclear Information System (INIS)

    Eager, K.M.

    1995-01-01

    This document presents the results of a preliminary investigation into options for preliminary flowsheets for 99Tc removal from Hanford Site tank waste. A model is created to show the path of 99Tc through pretreatment to disposal. The Tank Waste Remediation (TWRS) flowsheet (Orme 1995) is used as a baseline. Ranges of important inputs to the model are developed, such as 99Tc inventory in the tanks and important splits through the TWRS flowsheet. Several technetium removal options are discussed along with sensitivities of the removal schemes to important model parameters

  11. Immobilization of technetium and nitrate in cement-based materials

    International Nuclear Information System (INIS)

    Tallent, O.K.; McDaniel, E.W.; Del Cul, G.D.; Dodson, K.E.; Trotter, D.R.

    1987-01-01

    The leachabilities of technetium and nitrate wastes immobilized in cement-based grouts have been investigated. Factors found to affect the leachabilities include grout mix ratio, grout fluid density, dry solid blend composition, and waste concentration. 10 refs., 7 figs., 3 tabs

  12. Thallium-201 myocardial scintigraphy and cardiac pool scintigraphy with technetium-99m labelled human serum albumin of complicated anomalous heart

    International Nuclear Information System (INIS)

    Tanaka, Minoru; Watanabe, Takashi; Murase, Mitsuya; Shimizu, Ken; Abe, Toshio

    1979-01-01

    Nuclear cardiology has been used in the diagnosis of congenital heart disease, but these studies have not shown the dramatic increase that has occurred in their use in coronary heart disease. In this report, thallium-201 myocardial scintigraphy and cardiac pool scintigraphy with technetium-99m labelled human serum albumin of 13 patients with complicated congenital heart disease were compared with contrast angiography. The application of these scanning methods to visualization of the size and shape of ventricle and interventricular septum was very useful. At times these methods give us the more accurate information about cardiac shape, especially of complicated anomalous heart, than contrast angiography. Of course these methods will never replace cardiac catheterization and contrast angiography. But these studies are non-invasive. So it was concluded that these scanning methods had better be applied in patients with complicated cardiac anomaly before invasive contrast angiography. (author)

  13. Diagnostic strategies in osteomyelitis

    International Nuclear Information System (INIS)

    Wheat, J.

    1985-01-01

    Technetium- 99 pyrophosphate bone scanning often identifies patients with osteomyelitis before roentgenographic findings appear. However, recent studies have shown that 99 Tc bone scanning often gives false-negative results, especially in neonates. The accuracy of computed tomographic scanning and indium-111 leukocyte scanning for diagnosis of early osteomyelitis has not been established. 99 Tc bone scanning often gives false-positive results in patients with other conditions leading to bone injury and repair, such as trauma or recent surgery, further limiting the usefulness of this imaging procedure. Newer imaging techniques have not been adequately evaluated to establish their specificity. Because of their high cost and unproved accuracy, these new imaging procedures should not be routinely applied until their usefulness has been established. Bone biopsy remains the procedure of choice for establishing the diagnosis in patients suspected clinically to have osteomyelitis with negative findings on roentgenography and 99 Tc bone scanning. Although Staphylococcus aureus is the leading cause of osteomyelitis, other pathogens cause 30 to 40 percent of cases. Aspiration or biopsy of the involved bone is usually required to choose appropriate antibiotic therapy. Bone biopsy is essential in chronic osteomyelitis, since cultures of sinus drainage are unreliable. Osteomyelitis in diabetics with foot infection and in association with decubitus ulcers presents special problems. Radionuclide scanning often give false-positive results in these patients. Proper diagnosis usually requires careful assessment of clinical and roentgenographic findings. 33 references

  14. Technetium-99m mercaptoacetyltriglycine clearance: reference values for infants and children

    Energy Technology Data Exchange (ETDEWEB)

    Schofer, O. [Department of Pediatrics, Johannes-Gutenberg University, Mainz (Germany); Koenig, G. [Department of Pediatrics, Johannes-Gutenberg University, Mainz (Germany); Bartels, U. [Department of Pediatrics, Johannes-Gutenberg University, Mainz (Germany); Bockisch, A. [Department of Nuclear Medicine, Johannes-Gutenberg University, Mainz (Germany); Piepenburg, R. [Department of Nuclear Medicine, Johannes-Gutenberg University, Mainz (Germany); Beetz, R. [Department of Pediatrics, Johannes-Gutenberg University, Mainz (Germany); Meyer, G. [Department of Nuclear Medicine, Ludwig Maximilians University, Munich (Germany); Hahn, K. [Department of Nuclear Medicine, Ludwig Maximilians University, Munich (Germany)

    1995-11-01

    Six hundred and thirty-nine clearance studies performed in children aged 7 days to 19 years utilizing technetium-99m mercaptoacetyltriglycine (MAG 3) were retrospectively analysed. Standardized conditions for the investigation included: parenteral hydration (60 ml/hxm{sup 2} body surface) in addition to normal oral fluid intake, weight-related dose of {sup 99m}Tc-MAG 3 (1 MBq/kg body weight, minimum 15 MBq) and calculation of clearance according to Bubeck et al. Of the 513 children, 169 included in this analysis could be classified as ``normal`` with regard to their renal function. Normal kidney function was judged by the following criteria: normal GFR for age, normal tubular function (absence of proteinuria and glucosuria), normal renal parenchyma (on ultrasonography, MAG 3 scan and intravenous pyelography), absence of significant obstruction and gross reflux (> grade I) no single kidney and no difference in split renal function > 20%. Results showed increasing MAG 3 clearance values for infants during the first months of life, reaching the normal range for older children and adults between 7 and 12 months. (orig.)

  15. Technetium-99m mercaptoacetyltriglycine clearance: reference values for infants and children

    International Nuclear Information System (INIS)

    Schofer, O.; Koenig, G.; Bartels, U.; Bockisch, A.; Piepenburg, R.; Beetz, R.; Meyer, G.; Hahn, K.

    1995-01-01

    Six hundred and thirty-nine clearance studies performed in children aged 7 days to 19 years utilizing technetium-99m mercaptoacetyltriglycine (MAG 3) were retrospectively analysed. Standardized conditions for the investigation included: parenteral hydration (60 ml/hxm 2 body surface) in addition to normal oral fluid intake, weight-related dose of 99m Tc-MAG 3 (1 MBq/kg body weight, minimum 15 MBq) and calculation of clearance according to Bubeck et al. Of the 513 children, 169 included in this analysis could be classified as ''normal'' with regard to their renal function. Normal kidney function was judged by the following criteria: normal GFR for age, normal tubular function (absence of proteinuria and glucosuria), normal renal parenchyma (on ultrasonography, MAG 3 scan and intravenous pyelography), absence of significant obstruction and gross reflux (> grade I) no single kidney and no difference in split renal function > 20%. Results showed increasing MAG 3 clearance values for infants during the first months of life, reaching the normal range for older children and adults between 7 and 12 months. (orig.)

  16. Application of the ruthenium and technetium thermodynamic data bases used in the EQ3/6 geochemical codes

    Energy Technology Data Exchange (ETDEWEB)

    Isherwood, D.

    1985-04-01

    Based on a critical review of the available thermodynamic data, computerized data bases for technetium and ruthenium were created for use with the EQ3/6 geochemical computer codes. The technetium data base contains thermodynamic data for 8 aqueous species and 15 solids; 26 aqueous species and 9 solids were included in the ruthenium data base. The EQ3NR code was used to calculate solubility limits for ruthenium (8 x 10{sup -16} M) in ground water from Yucca Mountain, a potential nuclear waste repository site near the Nevada Test Site (NTS). The code confirmed the essentially unlimited solubility of technetium in oxidizing conditions, such as those that are believed to exist in the unsaturated zone at Yucca Mountain and the Cambric Nuclear event site at the NTS. Ruthenium migration observed from the Cambric site was evaluated. The solubility limit for ruthenium (as the aqueous species RuO{sub 4}{sup -}) when constrained by RuO{sub 2} is approximately equal to the concentration of ruthenium found in the cavity ground water (i.e., 2.1 x 10{sup -11} vs 4.5 x 10{sup -11} M). Differences in ruthenium solubility limits between Yucca Mountain and Cambric are primarily due to differences in ground-water pH. Technetium solubility (3 x 10{sup -8} M) for moderately reducing conditions (Eh = -0.1 V) using the metastable oxide, TcO{sub 2}.2H{sub 2}O, as the solubility constraint is within the range of experimental values recently published in a study of technetium sorption on basalt. Previously published technetium solubilities of 10{sup -12} to 10{sup -16} M were apparently based on a technetium data base that did not include aqueous species other than TcO{sub 4}{sup -}. When TcO(OH){sub 2}{sup 0} is included in the data base, the calculated values are much closer to the experimental results. Eh-pH diagrams were also generated for a variety of conditions using the SOLUPLOT code.

  17. Application of the ruthenium and technetium thermodynamic data bases used in the EQ3/6 geochemical codes

    International Nuclear Information System (INIS)

    Isherwood, D.

    1985-04-01

    Based on a critical review of the available thermodynamic data, computerized data bases for technetium and ruthenium were created for use with the EQ3/6 geochemical computer codes. The technetium data base contains thermodynamic data for 8 aqueous species and 15 solids; 26 aqueous species and 9 solids were included in the ruthenium data base. The EQ3NR code was used to calculate solubility limits for ruthenium (8 x 10 -16 M) in ground water from Yucca Mountain, a potential nuclear waste repository site near the Nevada Test Site (NTS). The code confirmed the essentially unlimited solubility of technetium in oxidizing conditions, such as those that are believed to exist in the unsaturated zone at Yucca Mountain and the Cambric Nuclear event site at the NTS. Ruthenium migration observed from the Cambric site was evaluated. The solubility limit for ruthenium (as the aqueous species RuO 4 - ) when constrained by RuO 2 is approximately equal to the concentration of ruthenium found in the cavity ground water (i.e., 2.1 x 10 -11 vs 4.5 x 10 -11 M). Differences in ruthenium solubility limits between Yucca Mountain and Cambric are primarily due to differences in ground-water pH. Technetium solubility (3 x 10 -8 M) for moderately reducing conditions (Eh = -0.1 V) using the metastable oxide, TcO 2 .2H 2 O, as the solubility constraint is within the range of experimental values recently published in a study of technetium sorption on basalt. Previously published technetium solubilities of 10 -12 to 10 -16 M were apparently based on a technetium data base that did not include aqueous species other than TcO 4 - . When TcO(OH) 2 0 is included in the data base, the calculated values are much closer to the experimental results. Eh-pH diagrams were also generated for a variety of conditions using the SOLUPLOT code

  18. Technetium: The First Radioelement on the Periodic Table

    Science.gov (United States)

    Johnstone, Erik V.; Yates, Mary Anne; Poineau, Frederic; Sattelberger, Alfred P.; Czerwinski, Kenneth R.

    2017-01-01

    The radioactive nature of technetium is discussed using a combination of introductory nuclear physics concepts and empirical trends observed in the chart of the nuclides and the periodic table of the elements. Trends such as the enhanced stability of nucleon pairs, magic numbers, and Mattauch's rule are described. The concepts of nuclear binding…

  19. Determination of the vitality of the femoral head with sup(99m)Tc-Sn-pyrophosphate scintigraphy

    International Nuclear Information System (INIS)

    Greiff, J.

    1980-01-01

    A series of 14 patients who for various reasons were scheduled for total hip replacement were investigated. sup(99m)Tc-Sn-pyrophosphate scintigraphy and tetracycline labelling of the bone structure was performed prior to surgery, and subsequently the femoral heads were submitted to histological evaluation on decalcified as well as non-decalcified slides. The evaluation of the scintigraphs was performed by a specialist in nuclear medicine and the histological slides were evaluated by a pathologist, in the both cases without the radiological findings or the clinical history. The scintigraphic evaluations of the vitality of the femoral head were in all cases verified by the histological examination, whereas the radiological findings in three cases failed to demonstrate that a femoral head necrosis actually was present. From this study it can be concluded that sup(99m)Tc-Sn-pyrophosphate scintigraphy is an excellent method of assessing bone vitality in the femoral head. (author)

  20. Study of the electrochemical behaviour of technetium on mercury in an acetic buffer medium; Etude du comportement electrochimique du technetium sur mercure en milieu acetique tamponne

    Energy Technology Data Exchange (ETDEWEB)

    Courson, Olivier [Inst. de Physique Nucleaire, Paris-11 Univ., 91 - Orsay (France)

    1997-11-07

    Technetium 99, produced with a high yield as fission product of {sup 235}U in nuclear reactors constitutes an important issue in the nuclear waste management. The rich and complex solution chemistry leads up to now to an insufficient knowledge of its behaviour in PUREX process and in environment. In order to understand the reduction mechanism of pertechnetate on mercury electrode, we have developed electrochemical techniques which use an additional time parameter to classical techniques used on mercury electrode. On micro-electrode, we have observed, for long time measurements (3D polarography), a split of the first polarographic wave into two waves, which characterizes the reduction of Tc(VII) in Tc(III) as well as a modification of the catalytic peak associated with technetium metal formation. moreover, differential capacitance determination of electrode/solution interface brings to the fore the existence of species (Tc(IV), T(0)) on mercury in the reduction zone corresponding to the following reductions: Tc(VII) -> T(III) and T(III) -> Tc(0). Moreover the Tc(III)/Tc(0) reduction brings the intermediary Tc(I) and Tc(II) which are present only for rates faster than the scan. Results obtained on microelectrodes have been confirmed on macro-electrode; the insoluble species Tc(IV) and Tc are formed during the reduction of Tc(VII) on metal. Thus, in acetate buffer media (pH=4.6), the pertechnetate reduction is characterized by the presence of absorbable species (Tc O{sub 2} hydrated,Tc). Moreover, the different electrochemical responses obtained with our techniques like 3D-polarography (waves and catalytic peaks) can be attributed to the following steps: Tc(VII)->Tc(V), Tc(IV) -> Tc(III), Tc(III) -> Tc(I) and Tc(I) -> Tc(0). The Tc(V) formation is followed by the rapid disproportionation of Tc(V) and Tc(VI) and Tc(I) reduction is associated with the proton reduction. (author) 124 refs., 68 figs., 19 tabs.

  1. Leaching of actinides and technetium from simulated high-level waste glass

    International Nuclear Information System (INIS)

    Bradley, D.J.; Harvey, C.O.; Turcotte, R.P.

    1979-08-01

    Leach tests were conducted using a modified version of the IAEA procedure to study the behavior of glass waste-solution interactions. Release rates were determined for Tc, U, Np, Pu, Am, Cm, and Si in the following solutions: WIPP B salt brine, NaCl (287 g/l), NaCl (1.76 g/1), CaCl 2 (1.66 g/l), NaHCO 3 (2.52 g/l), and deionized water. The leach rates for all elements decreased an order of magnitude from their initial values during the first 20 to 30 days leaching time. The sodium bicarbonate solution produced the highest elemental release rates, while the saturated salt brine and deionized water in general gave the lowest release. Technetium has the highest initial release of all elements studied. The technetium release rates, however, decreased by over four orders of magnitude in 150 days of leaching time. In the prepared glass, technetium was phase separated, concentrating on internal pore surfaces. Neptunium, in all cases except CaCl 2 solution, shows the highest actinide release rate. In general, curium and uranium have the lowest release rates. The range of actinide release rates is from 10 -5 to 10 -8 g/cm 2 /day. 25 figures, 7 tables

  2. Labelling of biological structures with technetium 99 m

    International Nuclear Information System (INIS)

    Bernardo Filho, M.

    1988-01-01

    The labelling of red blood cells (RBC) with technetium 99m ( 99m Tc) depends on several factors, as the stannous ion (Sn ++ ) concentration, the time and temperature of incubation, the anticoagulant utilized, the presence of plasma proteins (PP) and others. Although the blinding of 99m Tc with hemoglobin and PP are similar, they appear to have specific characteristics as demonstrated by precipitation with alcohol, acetone, trichloroacetic acid, hydrochloric acid and mercury chloride. The bacterial cultures labeled with Technetium- 99m , at optimal Sn ++ ion concentration, presents a large stability and their viability is not altered by this treatment. The electrophoretic mobility, the hydrophobicity, the cationized ferritin distribution and the adherence to human buccal epithelial cells are not modified either. The possibility of labelling with 99m Tc of planaria and cercariae of Schistossoma mansoni evaluative cycle increases the utilization of this radionuclide to an experimental level. The results described with the labelling of these biological structures with 99m Tc demonstrated that stable labeled and viable operations are obtained. (author)

  3. Technetium-99m sestamibi: an indicator of breast cancer invasiveness

    Energy Technology Data Exchange (ETDEWEB)

    Scopinaro, F. (Section of Nuclear Medicine, Dept. of Experimental Medicine, Univ. ' La Sapienza' , Rome (Italy)); Schillaci, O. (Section of Nuclear Medicine, Dept. of Experimental Medicine, Univ. ' La Sapienza' , Rome (Italy)); Scarpini, M. (1st Inst. of Surgery, Univ. ' La Sapienza' , Rome (Italy)); Mingazzini, P.L. (1st Inst. of Surgery, Univ. ' La Sapienza' , Rome (Italy)); Di Macio, L. (Section of Nuclear Medicine, Dept. of Experimental Medicine, Univ. ' La Sapienza' , Rome (Italy)); Banci, M. (Section of Nuclear Medicine, Dept. of Experimental Medicine, Univ. ' La Sapienza' , Rome (Italy)); Danieli, R. (Section of Nuclear Medicine, Dept. of Experimental Medicine, Univ. ' La Sapienza' , Rome (Italy)); Zerilli, M. (1st Inst. of Surgery, Univ. ' La Sapienza' , Rome (Italy)); Limiti, M.R. (1st Inst. of Surgery, Univ. ' La Sapienza' , Rome (Italy)); Centi Colella, A. (Section of Nuclear Medicine, Dept. of Experimental Medicine, Univ. ' La Sapienza' , Rome (Italy))

    1994-09-01

    As recently shown, angiogenesis is the most reliable marker of breast cancer invasiveness. Unfortunately it must be assessed by immunohistochemistry on tissue specimens. We have used technetium-99m sestamibi, a marker of regional blood flow in other organs that often but not always images breast cancer, to assess the invasiveness of this tumour. Nineteen patients, ten with nodal metastases and nine without any metastases, were studied with [sup 99m]Tc-sestamibi scintigraphy before operation. Angiogenesis was quantitatively assessed by immunohistochemical staining of endothelia for factor VIII. All the node-positive (N+) patients at surgical revesion showed a positive [sup 99m]Tc-sestamibi scan of the primary tumour and all the N-patients were negative. Nine out of ten N+ and sestamibi-positive tumours showed more than 135 microvessels/mm[sup 2] and one showed 99 microvessels/mm[sup 2]; by contrast there were 71.6[+-]12.1 microvessels/mm[sup 2] in the nine N- and sestamibi-negative tumours. Our study suggests that [sup 99m]Tc-sestamibi is a marker of breast cancer invasiveness: its uptake is related to angiogenesis and, possibly, to oxidative metabolism of the tumour. (orig.)

  4. Transfer across the human gut of environmental technetium in lobsters (Homarus gammarus L.) from the Irish Sea

    Energy Technology Data Exchange (ETDEWEB)

    Hunt, G.J. [The Centre for Environment, Fisheries and Aquaculture Science, Lowestoft Laboratory, Pakefield Road, Lowestoft, Suffolk NR33 0HT (United Kingdom)]. E-mail: g.j.hunt@cefas.co.uk; Young, A.K.; Bonfield, R.A. [The Centre for Environment, Fisheries and Aquaculture Science, Lowestoft Laboratory, Pakefield Road, Lowestoft, Suffolk NR33 0HT (United Kingdom)

    2001-03-01

    Few data are available on the uptake by the human gut of the element technetium. Of current radiological interest in connection with discharges of technetium-99 in liquid discharges from BNFL, Sellafield, is uptake from European lobsters (Homarus gammarus), whose edible parts are known to concentrate technetium. In this study, a group of eight adult volunteers (six males and two females) ate samples of edible flesh from lobsters caught off the west Cumbrian coast and provided 24 h samples of urine and faeces for analysis. Detection of uptake from the gut by difference between intake and faecal measurements proved insensitive, suggesting a low value of the gut transfer factor (f{sub 1} value) of up to 0.1 with a maximum (two standard deviations) level of about 0.3. In urine, technetium was detectable at a relatively low level compared with the intakes, consistent with a low absorption across the gut. Values for f{sub 1} were derived with the aid of literature data for excretion following intravenous administration of technetium-95m as pertechnetate, and gave averaged data for f{sub 1} in the range 0.046 to 0.23. These results are in broad conformity with those derived from the faecal measurements, and suggest a lower value than the 0.5 used by ICRP. (author)

  5. Scintigraphy of sacroliac joints in acute anterior uveitis. A study of thirty patients

    International Nuclear Information System (INIS)

    Russell, A.S.; Lentle, B.C.; Percy, J.S.; Jackson, F.I.

    1976-01-01

    HLA-B27 is a transplantation antigen found in a high proportion of patients with ankylosing spondylitis. Recently, an association has been shown to exist between HLA-B27 and acute uveitis, even in the absence of ankylosing spondylitis. We have examined the HLA antigen profile of 45 patients with acute nongranulomatous anterior uveitis and have confirmed this relation. In addition, using 90m technetium stannous pyrophosphate we have been able to demonstrate abnormal bone scan in 19 of 30 patients studied. Such abnormalities are limited to the sacroiliac joints but are otherwise the same as those seen in overt ankylosing spondylitis. Seven of the 19 patients did not have HLA-B27. These factors suggest that acute anterior uveitis may often represent a manifestation of a spondylitic diathesis even in the complete absence of any suggestive symptomatic or radiologic change and, in some cases, even through the antigenic marker HLA-B27 may be absent

  6. Biogeochemical Controls on Technetium Mobility in Biogeochemical Controls on Technetium Mobility in FRC Sediments

    International Nuclear Information System (INIS)

    Lloyd, J.R.; McBeth, J.M.; Livens, F.R.; Bryan, N.D.; Ellis, B.; Sharma, H.; Burke, I.T.; Morris, K.

    2004-01-01

    Technetium-99 is a priority pollutant at numerous DOE sites, due to its long half-life (2.1 x 10 5 years), high mobility as Tc(VII) in oxic waters, and bioavailability as a sulfate analog. 99 Tc is far less mobile under anaerobic conditions, forming insoluble Tc(IV) precipitates. As anaerobic microorganisms can reduce soluble Tc(VII) to insoluble Tc(IV), microbial metabolism may have the potential to treat sediments and waters contaminated with Tc. Baseline studies of fundamental mechanisms of Tc(VII) bioreduction and precipitation (reviewed by Lloyd et al, 2002) have generally used pure cultures of metal-reducing bacteria, in order to develop conceptual models for the biogeochemical cycling of Tc. There is, however, comparatively little known about interactions of metal-reducing bacteria with environmentally relevant trace concentrations of Tc, against a more complex biogeochemical background provided by mixed microbial communities in the subsurface. The objective of this new NABIR project is to probe the site specific biogeochemical conditions that control the mobility of Tc at the FRC (Oak Ridge, TN). This information is required for the rational design of in situ bioremediation strategies for technetium-contaminated subsurface environments. We will use a combination of geochemical, mineralogical, microbiological and spectroscopic techniques to determine the solubility and phase associations of Tc in FRC sediments, and characterize the underpinning biogeochemical controls. A key strength of this project is that many of the techniques we are using have already been optimized by our research team, who are also studying the biogeochemical controls on Tc mobility in marine and freshwater sediments in the UK in a NERC funded companion study.

  7. EPR investigations on technetium compounds

    International Nuclear Information System (INIS)

    Abram, U.; Munze, R.; Kirmse, R.; Stach, J.

    1986-01-01

    Stimulated by the widespread use of the isotope /sup 99m/Tc in the field of nuclear medicine, there has been a substantial growth of interest in the chemistry of this man-made element. A particular need emerges for analytical methods allowing solution investigations of coordination compounds of technetium with low substance use. Considering these facts, Electron Paramagnetic Resonance Spectroscopy (EPR) appears to be a very suitable method because only very small amounts of the compounds are needed (lower than 1 mg). The resulting spectra give information regarding the valence state, symmetry and bonding properties of the compounds under study

  8. Immobilization and Limited Reoxidation of Technetium-99 by Fe(II)-Goethite

    Energy Technology Data Exchange (ETDEWEB)

    Um, Wooyong; Chang, Hyun-shik; Icenhower, Jonathan P.; Qafoku, Nikolla; Smith, Steven C.; Serne, R. Jeffrey; Buck, Edgar C.; Kukkadapu, Ravi K.; Bowden, Mark E.; Westsik, Joseph H.; Lukens, Wayne W.

    2010-09-30

    This report summarizes the methodology used to test the sequestration of technetium-99 present in both deionized water and simulated Hanford Tank Waste Treatment and Immobilization Plant waste solutions.

  9. Preliminary study of the migration of technetium in soil under hydrous conditions

    International Nuclear Information System (INIS)

    Sisson, D.H.; MacLean, S.C.; Schulz, R.K.; Borg, R.J.

    1979-01-01

    The sorption of technetium compared to sodium, cesium, and strontium by a common agricultural soil was measured using a column method. As expected, no sorption of Tc occurred under conditions that substantially removed Na + , Cs + , and Sr ++ . High radioactivity levels were used to establish absorption profiles over six orders of magnitude of tracer concentration. Behavior of initially dry columns was compared with that of initially water-saturated columns; the results were not quantitatively different although there was a qualitative difference in the appearance of the profiles. Technetium tracked the moisture content of the column and hence migrated at the veloccity of the aqueous medium

  10. Technetium and diazotrophic organisms: toxicity, localization, transfer factors

    International Nuclear Information System (INIS)

    Vandecasteele, C.M.; Delmotte, A.; Roucoux, P.; Hove, C. van

    1982-01-01

    Three diazotrophic organisms, together with one leguminous organism in symbiosis with one of them, were cultivated in the presence of various quantities of technetium, of which the localization, transfer factors and toxicity were studied in relation to the age of the organisms and their type of metabolism. The paper discusses the biochemical aspects of the results. (author)

  11. Assessment of the Cast Stone Low-Temperature Waste Form Technology Coupled with Technetium Removal - 14379

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Christopher F.; Rapko, Brian M.; Serne, R. Jeffrey; Westsik, Joseph H.; Cozzi, Alex; Fox, Kevin M.; Mccabe, Daniel J.; Nash, C. A.; Wilmarth, William R.

    2014-03-03

    The U.S. Department of Energy Office of Environmental Management (EM) is engaging the national laboratories to provide the scientific and technological rigor to support EM program and project planning, technology development and deployment, project execution, and assessment of program outcomes. As an early demonstration of this new responsibility, Pacific Northwest National Laboratory (PNNL) and Savannah River National Laboratory (SRNL) were chartered to implement a science and technology program addressing low-temperature waste forms for immobilization of DOE aqueous waste streams, including technetium removal as an implementing technology. As a first step, the laboratories examined the technical risks and uncertainties associated with the Cast Stone waste immobilization and technetium removal projects at Hanford. Science and technology gaps were identified for work associated with 1) conducting performance assessments and risk assessments of waste form and disposal system performance, and 2) technetium chemistry in tank wastes and separation of technetium from waste processing streams. Technical approaches to address the science and technology gaps were identified and an initial sequencing priority was suggested. A subset of research was initiated in 2013 to begin addressing the most significant science and technology gaps. The purpose of this paper is to report progress made towards closing these gaps and provide notable highlights of results achieved to date.

  12. The retention mechanism of technetium-99m-HM-PAO

    DEFF Research Database (Denmark)

    Neirinckx, R D; Burke, J F; Harrison, R C

    1988-01-01

    Preparations of d,l- and meso-hexamethylpropyleneamine oxime (HM-PAO) labeled with technetium-99m were added to rat brain homogenates diluted with phosphate buffer (1:10). The conversion of d,l-HM-PAO to hydrophilic forms took place with an initial rate constant of 0.12 min-1. Incubation of the b......Preparations of d,l- and meso-hexamethylpropyleneamine oxime (HM-PAO) labeled with technetium-99m were added to rat brain homogenates diluted with phosphate buffer (1:10). The conversion of d,l-HM-PAO to hydrophilic forms took place with an initial rate constant of 0.12 min-1. Incubation....... This correspondence of values supports the notion that GSH may be important for the in vivo conversion of 99mTc-labeled HM-PAO to hydrophilic forms and may be the mechanism of trapping in brain and other cells. A kinetic model for the trapping of d,l- and meso-HM-PAO in tissue is developed that is based on data...

  13. Environmental behavior of technetium in soil and vegetation: implications for radiological impact assessment

    International Nuclear Information System (INIS)

    Hoffman, F.O.

    1982-04-01

    Significant radiological exposures have been estimated for hypothetical atmospheric releases of Tc-99 from gaseous diffusion facilities when vegetation-to-soil concentration ratios representative of laboratory experiments are substituted for generic default values assumed in current regulatory models. To test the relevancy of these laboratory ratios, field investigations were conducted to obtain measurements of the vegetation-to-soil concentration ratio for Tc-99 in samples collected near operating gaseous diffusion facilities and to observe the dynamic behavior of technetium in soil and vegetation following a single application of a sprayed solution of /sup 95m/TcO 4 - Comparison of observed field concentration ratios and calculated steady-state concentration ratios with ratios obtained from previous laboratory experiments indicates that concentration ratios obtained from field data are one to two orders of magnitude less than those obtained from the laboratory. Furthermore, a substantial accumulation of technetium in soil and vegetation may not occur over long periods of time, since concentrations of technetium in both environmental media were observed to decrease with time subsequent to initial application of /sup 95m/TcO 4 -

  14. Review of technetium behavior in relation to nuclear waste disposal

    International Nuclear Information System (INIS)

    Paquette, J.; Reid, J.A.K.; Rosinger, E.L.J.

    1992-05-01

    This report contains available information which determine possible methods of the transfer of technetium element from waste disposal facilities to the biosphere. It also includes possible effects upon human beings and environment. 65 refs., 4 tabs., 3 figs

  15. Pyrophosphate synthesis in iron mineral films and membranes simulating prebiotic submarine hydrothermal precipitates

    Science.gov (United States)

    Barge, Laura M.; Doloboff, Ivria J.; Russell, Michael J.; VanderVelde, David; White, Lauren M.; Stucky, Galen D.; Baum, Marc M.; Zeytounian, John; Kidd, Richard; Kanik, Isik

    2014-03-01

    Cells use three main ways of generating energy currency to drive metabolism: (i) conversion of adenosine diphosphate (ADP) to adenosine triphosphate (ATP) by the proton motive force through the rotor-stator ATP synthase; (ii) the synthesis of inorganic phosphate˜phosphate bonds via proton (or sodium) pyrophosphate synthase; or (iii) substrate-level phosphorylation through the direct donation from an active phosphoryl donor. A mechanism to produce a pyrophosphate bond as “energy currency” in prebiotic systems is one of the most important considerations for origin of life research. Baltscheffsky (1996) suggests that inorganic pyrophosphate (PO74-; PPi) may have preceded ATP/ADP as an energy storage molecule in earliest life, produced by an H+ pyrophosphatase. Here we test the hypothesis that PPi could be synthesized in inorganic precipitates simulating hydrothermal chimney structures transected by thermal and/or ionic gradients. Appreciable yields of PPi were obtained via substrate phosphorylation by acetyl phosphate within the iron sulfide/silicate precipitates at temperatures expected for an alkaline hydrothermal system. The formation of PPi only occurred in the solid phase, i.e. when both Pi and the phosphoryl donor were precipitated with Fe-sulfides or Fe-silicates. The amount of Ac-Pi incorporated into the precipitate was a significant factor in the amount of PPi that could form, and phosphate species were more effectively incorporated into the precipitate at higher temperatures (⩾50 to >85 °C). Thus, we expect that the hydrothermal precipitate would be more enriched in phosphate (and especially, Ac-Pi) near the inner margins of a hydrothermal mound where PPi formation would be at a maximum. Iron sulfide and iron silicate precipitates effectively stabilized Ac-Pi and PPi against hydrolysis (relative to hydrolysis in aqueous solution). Thus it is plausible that PPi could accumulate as an energy currency up to useful concentrations for early life in a

  16. Technetium-99 in lobsters from the western Irish sea

    International Nuclear Information System (INIS)

    Fegan, Mary

    1999-05-01

    Technetium-99, the most important radionuclide of technetium release to the environment, is a pure beta emitter with a half-life of 2.13 x 10(5) years. It behaves conservatively in seawater and is likely to remain available to biota for a long time. The dominant and most stable form of technetium in oxygenated seawater is the pertechnetate ion, Tco4. The principle source of radionuclide contamination of the Irish Sea has been the liquid waste discharges of low level radionuclide effluent from the spent nuclear fuel reprocessing plant at Sellafield on the Cumbria Coast. In 1994 the annual discharge authorization limit for 99Tc was increased from 10 TBq to 200 TBq. Lobster concentrates 99Tc to a high degree with concentration factors of 1x 10(3) reported in the literature. The mean 99Tc activity concentrations in lobsters caught close to Sellafield were reported to have risen by a factor of 20 in 2 years from 390 Bq/kg (wet weight) in 1993 to 8300 Bq/kg (wet weight) in 1995. This study was undertaken to determine the 99Tc activity concentration in lobsters from the western Irish Sea. Lobsters were collected from the east and north east coasts of Ireland over the period June 1997 to July 1998 and analysed using a radioanalytical method which was based on the anion-exchange seperation of technetium as pertechnetate. A gas-flow proportional counter was used to measure to 99Tc activity concentration in each sample. Technetium-99 activity concentrations were measured in the muscle from the tail, the right and the left claws and also in the green gland, the hepatopancreas and the cardiac fore-gut. The results of the measurements showed, as expected, that the 99Tc activity concentrations were not as high as those in the samples from the Cumbrian coast. The mean 99Tc activity concentrations, over the sampling period, in the tail, right and left claw muscles were 214, 124 and 136 BQ/kg (wet weight) respectively. The mean 99Tc activity concentrations in the green gland

  17. Preclinical evaluation of technetium 99m-labeled P1827DS for infection imaging and comparison with technetium 99m IL-8.

    NARCIS (Netherlands)

    Krause, S.; Rennen, H.J.J.M.; Boerman, O.C.; Baumann, S.; Cyr, J.E.; Manchanda, R.; Lister-James, J.; Corstens, F.H.M.; Dinkelborg, L.M.

    2007-01-01

    BACKGROUND: The technetium 99 m (99mTc)-radiolabeled, leukocyte-avid peptide-glycoseaminoglycan complex, [99mTc]P1827DS, has been synthesized as an improved infection/inflammation imaging agent to [99mTc]P483H (LeukoTect, Diatide). In a phase I/II clinical trail, [99mTc]P483H images were equivalent

  18. A negative bone scan leads to an unusual diagnosis

    International Nuclear Information System (INIS)

    O'Brien, L.

    1998-01-01

    Full text: A bone scan looking for osteomyelitis or a more sinister pathology was performed on a 7-year-old boy with Von Willebrand''s disease. He presented with symptoms of pain in the left groin and a lump, although there had been no history of direct trauma, and an X-ray report stating that there was an irregular ill-defined area of bony destruction seen in the lower aspect of the left ischium. Blood pool images of the pelvis were acquired soon after an injection of MDP and three hours later a whole body bone scan was done. Results of the bone scan showed that the radiolucent lesion in the left ilium seen on the plain radiographs was not metabolically active on the technetium MDP study. Features compatible with a response to an intraosseous or sub-periosteal haematoma were seen when reviewing the original X-rays and, as there was a spontaneous resolution of the patient''s symptoms, this was considered to be the diagnosis. This study shows that a negative bone scan, which rules out an active bone lesion, is of value in making a diagnosis when used in conjunction with X-rays and a knowledge of the patient''s history

  19. Bone marrow immunoscintigraphy using technetium-99m anti-granulocyte antibody in multiple myeloma

    International Nuclear Information System (INIS)

    Sohn, Sang-Kyun; Kim, Dong-Hwan; Park, So-Hyang; Ahn, Byeong-Cheol; Lee, Sang-Woo; Chun, Kyung-Ah; Kim, Jung-Gyun; Lee, Kyu Bo; Lee, Jaetae; Song, Hong-Suk

    2002-01-01

    Conventional skeletal radiography and bone scan have certain limitations in the initial evaluation of bone and bone marrow lesions in multiple myeloma (MM). In this study we investigated the value of bone marrow immunoscintigraphy (BMIS) using anti-granulocyte monoclonal antibody (AGA) for the diagnosis of bone involvement of MM, in comparison with bone scan and skeletal radiography. Whole-body BMIS using technetium-99m-labelled AGA was performed in 22 MM patients (15 male, 7 female) and the imaging findings compared with those of skeletal radiography and 99m Tc-methylene diphosphonate bone scan. The findings of bone marrow aspiration and serum biochemical findings were also compared with BMIS findings. Abnormal findings of BMIS were defined as presence of a focal photon defect in the axial skeleton or expansion of peripheral bone marrow. A total of 124 focal lesions were detected in 19 subjects (86%) by skeletal radiography, bone scan or BMIS. BMIS detected 92 lesions (74%) in 19 subjects, whereas skeletal radiography detected 58 focal lesions (47%) in 14 and bone scan 40 lesions (32%) in 11. Fifty-one (41%) of the 124 lesions were only seen on BMIS. Spine and pelvic lesions were better visualised by BMIS, whereas skull lesions were better seen with skeletal radiography, and bone scan detected more lesions in the ribs. Marrow expansion was noted in 15 subjects (68%) on BMIS, and its grade correlated with marrow cellularity and myeloma cell percentage in bone marrow aspirates (P=0.0055 and P=0.0541, respectively). BMIS revealed abnormal lesions in one of three stage II patients and 17 out of 19 stage III patients. The number of lesions of the thoracolumbar vertebrae on BMIS was correlated with cellularity (P=0.0393), but not with myeloma cell percentage (P=0.1262). These findings suggest that the results of BMIS with 99m Tc-labelled AGA correlate with clinical stage, and thus reflect the functional status of bone marrow in MM patients. BMIS might be useful for the

  20. Equilibrium blood pool scanning in the evaluation of hemophilic arthropathy

    International Nuclear Information System (INIS)

    Spies, S.; Green, D.; Rana, N.A.; Milgram, J.W.; Mintzer, R.

    1978-01-01

    Arthropathy was evaluated in six patients with severe hemophilia (factor VIII<1%) using the technique of blood pool scanning. Employing an in vivo method for erythrocyte labelling with technetium-99m, a dynamic perfusion sequence was obtained using a scintillation camera over the joint(s) to be examined. Subsequently, equilibrium blood pool images of the joints were obtained to determine regional blood volume. In young patients with repeated episodes of acute hemarthrosis, increased vascularity and increased blood pool in the affected joints were demonstrated. In older patients with fixed, contracted joints and degenerative arthropathy, vascularity and regional blood volume were not abnormal. Blood pool scanning is a safe, non-invasive technique that augments the clinical and radiographic examination of the joints. The method is helpful in distinguishing acute joint bleeding from chronic synovitis and arthritis, and may prove useful in selecting patients for synovectomy. (author)

  1. Biliary scanning with /sup 99m/Tc pyridoxylideneglutamate. The effect of food in normal subjects: concise communication

    International Nuclear Information System (INIS)

    Baker, R.J.; Marion, M.A.

    1977-01-01

    Technetium-99m pyridoxylideneglutamate biliary scans were performed in 19 normal subjects in both the fasted and nonfasted state. The effect of eating was to reduce visualization of the gallbladder from 100% (fasted) to 47% (nonfasted). The common bile duct was seen in 84% on both occasions but intrahepatic and cystic ducts were seen less frequently in the nonfasted group. Preparation of patients by fasting is essential if information concerning gallbladder function is sought

  2. Automation drying unit molybdenum-zirconium gel radioisotope production technetium-99M for nuclear medicine

    International Nuclear Information System (INIS)

    Chakrova, Y.; Khromushin, I.; Medvedeva, Z.; Fettsov, I.

    2014-01-01

    Full text : Since 2001 the Institute of Nuclear Physics of the Republic of Kazakhstan has began production of radiopharmaceutical based on technetium-99m from irradiated reactor WWR-K of natural molybdenum, which allows to obtain a solution of technetium-99m of the required quality and high volume activity. In 2013 an automated system is started, which is unique and urgent task is to develop algorithms and software in Python, as well as the manufacture of certain elements of technological systems for automated production

  3. Behavior of technetium in paddy soils

    International Nuclear Information System (INIS)

    Yanagisawa, K.; Muramatsu, Y.; Ban-Nai, T.

    1997-01-01

    In order to understand the chemical form of soluble technetium in paddy soil and its availability to a rice plant, soil incubation and uptake experiments have been carried out using 95m Tc as a tracer. The chemical form of the soluble Tc was observed by gel chromatography and found not to be pertechnetate, but rather to be associated with soluble organic matter. An uptake experiment with rice seedlings using nutrient solution showed that this Tc-organic matter complex was less available than pertechnetate. (author)

  4. Technetium-99 in the Irish marine environment

    Energy Technology Data Exchange (ETDEWEB)

    Smith, V.; Fegan, M.; Pollard, D.; Long, S.; Hayden, E.; Ryan, T.P

    2001-07-01

    Technetium-99 activity concentrations in seawater and biota from Irish coastal waters are presented. Time series measurements of {sup 99}Tc in seawater and Fucus vesiculosus from the western Irish Sea show that activity concentrations have increased in line with the increase in discharges of {sup 99}Tc from Sellafield. The peak in activity concentrations in both seawater and Fucus vesiculosus occurred in 1997 approximately two years after the peak in {sup 99}Tc discharges. The highest activity concentration recorded in Fucus vesiculosus showed a 29-fold increase over the mean concentration for the period 1988-1993. Technetium-99 activity concentrations were measured in fish, lobsters, prawns, mussels and oysters landed at major fishing ports on the east and northeast coasts of Ireland between 1996 and 1998. Concentration factors for {sup 99}Tc in the brown seaweed Fucus vesiculosus and certain species of fish, crustaceans and molluscs from the Irish Sea were estimated. In general, these concentration factors were higher than those in the literature which were derived from laboratory studies, but agreed well with values which were based on field studies. The mean committed effective doses to Irish typical and heavy seafood consumers due to {sup 99}Tc in the period 1996-1998 were 0.061 and 0.24 {mu}Sv, respectively.

  5. Studies on the solvent extraction of technetium from thiocyanate solutions in mineral acids

    International Nuclear Information System (INIS)

    Ejaz, M.; Mamoon, A.M.

    1988-01-01

    Technetium-99m, separated from fission molybdenum-99 was studied as a component of liquid-liquid phase distribution equilibria. 5-(4-Pyridyl)nonane in a carrier diluent, benzene, was used to study the distribution of the nuclide from thermodynamically suitable aqueous phases of electrolytes with and without sterically receptive thiocyanate ions. Efficient extraction of the metal can be accomplished in a variety of aqueous phase compositions. The separation factors with respect to molybdenum, under certain experimental conditions, are fairly high. The data have been utilized to effect clean separations of technetium from molybdenum. (author) 39 refs.; 11 figs

  6. Gastrointestinal scanning agent

    International Nuclear Information System (INIS)

    Francis, M.D.

    1980-01-01

    An easily prepared radiolabeled gastrointestinal scanning agent is described. Technetium-99m has ideal characteristics for imaging the upper and lower GI tract and determining stomach emptying and intestinal transit time when used with an insoluble particulate material. For example, crystalline and amorphous calcium phosphate particles can be effectively labeled in a one-step process using sup(99m)TcO 4 and SnCl 2 . These labeled particles have insignificant mass and when administered orally pass through the GI tract unchanged, without affecting the handling and density of the intestinal contents. Visualization of the esophageal entry into the stomach, the greater and lesser curvatures of the stomach, ejection into the duodenum, and rates of passage through the upper and lower GI tract are obtained. The slurry of sup(99m)TC particulate can be given rectally by enema. Good images of the cecum and the ascending, transverse, and descending colon are obtained. Mucosal folds and the splenic and hepatic flexures are visualized. The resilience of the large intestine is also readily visualized by pneumocolonographic techniques. (author)

  7. Retrospective study of renal images on whole bone scanning

    International Nuclear Information System (INIS)

    Yanagisawa, Munetoshi; Machida, Toyohei; Miki, Makoto; Ohishi, Yukihiko; Ueda, Masataka

    1978-01-01

    One hundred and twenty-seven cases were surveyed by sup(99m)Tc-pyrophosphate at Jikei hospital. Renal images on whole-bone scanning were observed in all cases; 75% of all renal images were normal and 25% were abnormal. Thirteen percent of these abnormal images were symmetric and 87% were asymmetric. Four of the symmetric renal images were bilaterally bad. Three of the four bilaterally bad renal images involved prostate carcinomas with general metastases and the last involved serious bilateral hydronephrosis. The reason for the high percentage of asymmetric renal images was that the materials involved many urogenital cases. Asymmetric renal images other than the urogenital cases, were recognised in 8% of all cases. This percentage is consistent with Hattner's report. Unilateral abnormal renal images involved 8 hydronephrosis cases, 2 unilateral nonfunctioning kidneys and one malrotation kidney. Among the hydronephrosis cases, serious cases gave low uptake and mild cases gave high uptake. The reason for this phenomenon was, presumably, that there were differences in renal uptake, renal excretion and renal pelvic accumulation. In nine cases, one kidney was not visualized on whole-bone scanning, 8 of them involved nephrectomy and the remainining one unilateral nonfunctioning kidney. Six cases presented locally abnormal renal images on whole-bone scanning, three of them suffered renal cell carcinomas and the rest renal solitary cyst. Eighty-eight percent of the abnormal renal images agreed with IVP findings. The renal images of whole-bone scanning faithfully reflected the original renal lesion. Two cases of renal carcinoma and renal solitary cyst recognized on whole-bone scanning are presented, to indicate the usefulness of renal images on whole-bone scanning. (auth.)

  8. Diagnostic usefulness of technetium-99m (V) DMSA scintigraphy in cases of soft tissue tumors; In comparison with that of Ga-67 citrate scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Hisataka; Kotoura, Yoshihiko; Hanbara, Harumi; Hosono, Makoto; Yamamuro, Takao; Konishi, Junji (Kyoto Univ. (Japan). Faculty of Medicine)

    1994-05-01

    Technetium-99m (V) DMSA scintigraphy was performed in 76 patients with pathologically confirmed soft tissue diseases. In 56 patients, gallium-67 citrate scintigraphy was performed within two weeks after technetium-99m (V) DMSA scintigraphy. Significant uptake of technetium-99m (V) DMSA was found in all cases of sarcoma, metastatic carcinoma, progressive benignancy (extra-abdominal desmoid etc.) and granulomatous lesions, but was not found in cases of benign, solid tumors in the soft tissue (leiomyoma, neurinoma, lipoma etc.). In conclusion, it is not necessary to treat patients with soft tissue tumors in which technetium-99m (V) DMSA did not accumulate. Therefore, it can be stated that technetium-99m (V) DMSA scintigraphy is useful for the screening of malignant tumors. (author).

  9. Identification of Farnesyl Pyrophosphate and N-Arachidonylglycine as Endogenous Ligands for GPR92*S⃞

    OpenAIRE

    Oh, Da Young; Yoon, Jung Min; Moon, Mi Jin; Hwang, Jong-Ik; Choe, Han; Lee, Ju Yeon; Kim, Jae Il; Kim, Sunoh; Rhim, Hyewhon; O'Dell, David K.; Walker, J. Michael; Na, Heung Sik; Lee, Min Goo; Kwon, Hyuk Bang; Kim, Kyungjin

    2008-01-01

    A series of small compounds acting at the orphan G protein-coupled receptor GPR92 were screened using a signaling pathway-specific reporter assay system. Lipid-derived molecules including farnesyl pyrophosphate (FPP), N-arachidonylglycine (NAG), and lysophosphatidic acid were found to activate GPR92. FPP and lysophosphatidic acid were able to activate both Gq/11- and Gs-mediated signaling pathways, whereas NAG activated only the Gq/11-mediated signaling pathway. Co...

  10. Detection of pulmonary hemorrhage with technetium-labeled red cells

    International Nuclear Information System (INIS)

    Winzelberg, G.G.; Laman, D.; Sachs, M.; Miller, W.H.

    1981-01-01

    Noninvasive techniques to aid in the diagnosis of massive pulmonary hemoptysis would be helpful in guiding more-invasive procedures such as bronchial artery angiography, which carries a risk of transverse myelitis. A patient was studied with technetium-labeled red cells and successfully detected a site of intermittent hemorrhage from the lung

  11. An autosampling differential scanning calorimeter instrument for studying molecular interactions.

    Science.gov (United States)

    Plotnikov, Valerian; Rochalski, Andrew; Brandts, Michael; Brandts, John F; Williston, Samuel; Frasca, Verna; Lin, Lung-Nan

    2002-11-01

    A new ultrasensitive differential scanning calorimeter (DSC) instrument is described, which utilizes autosampling for continuous operation. High scanning rates to 250 deg/h with rapid cooling and equilibration between scans facilitates higher sample throughput up to 50 samples during each 24 h of unattended operation. The instrument is suited for those pharmaceutical applications where higher throughput is important, such as screening drug candidates for binding constant or screening solution conditions for stability of liquid protein formulations. Results are presented on the binding of five different anionic inhibitors to ribonuclease A, which included cytidine 2'-monophosphate (2'CMP), 3'CMP, uridine 3'-monophosphate, pyrophosphate, and phosphate. Binding constants K(B) (or dissociation constants K(d)) are obtained from the shift in the transition temperature T(M) for ribonuclease thermal unfolding in the presence of ligand relative to the transition temperature in the absence of ligand. Measured binding constants ranged from 155 M(-1) (K(d) = 6.45 mM) for the weak-binding phosphate anion to 13100 M(-1) (K(d) = 76.3 microM) for the strongest binding ligand, 2'CMP. The DSC method for measuring binding constants can also be extended to ultratight interactions involving either ligand-protein or protein-protein binding.

  12. Studies in technetium chemistry, Project 1: Evaluation of technetium acetylacetonates as potential cerebral blood flow agents, Project 2

    International Nuclear Information System (INIS)

    Jones, A.G.; Packard, A.B.; Treves, S.; Davison, A.

    1990-01-01

    Although the emphasis in our original submission was on N 2 S 2 and N 3 S coordinating ligands in technetium(V), we have now broadened the chemistry studies into areas that encompass new systems that allow the generation of neutral complexes. This change was based upon developments that have taken place in our basic chemistry studies that could bear on one of the original aims of this work, i.e., the design of complexes designed to penetrate cellular membranes and to remain trapped in target tissues. Among these topics are oxotechnetium(V) complexes containing amine and alcoholate ligands, coordination compounds containing the alternative technetium(V) nitrido core and the synthesis at macroscopic levels of a tetradentate ''umbrella'' ligand that successfully binds the metal. Basic studies with the original bisamide-bisthiol ligand system have continued with the identification of the products formed when aqueous solutions of the complex [TcO(ema)] - are acidified. This material is isolatable as yellow/brown crystals when HCl is added to the tetraphenylarsonium salt of the complex synthesized according to published procedures. Elemental analysis, FAB(+) mass spectrometry and 1 H NMR results were consistent with the formulation TcO(ema)H. Infrared spectra showed a dramatic shift in the Tc = O stretch to 966 cm -1 , as distinct from 945 cm -1 in the original complex

  13. Advantages and limits of sup(99m)Tc pyrophosphate scintigraphy in the study of joint diseases

    International Nuclear Information System (INIS)

    Caillard, J.-F.

    1975-01-01

    The results of sup(99m)Tc pyrophosphate bone scintigraphy are studied for a wide range of joint diseases. 215 scintigraphs are analysed, the results compared with those of authors who have used not only Tc phosphates but also other isotopes after comparison of their advantages and disadvantages, and possible applications suggested for each type of lesion. - The 99m Tc pyrophosphate scintigraphic examination is simple, harmless (a whole-skeleton examination delivers only 80 millirads to the narrow whereas a set of spine and pelvis X-rays delivers 325), reliable and highly sensitive, often anticipating data from radiographic examinations. - In the majority of developing joint diseases of whatever kind, apart from arthroses and certain osteolytic lesions unaccompanied by any healing reaction, a hyperfixation is observed. Generally speaking a scintigraph may be requested whenerver an evolutive bone lesion is suspected in the absence of clinical, radiological and biological evidence. The major disadvantage of the method is that, being highly sensitive, it lacks specificity and is hence unable alone to provide an etiological diagnosis [fr

  14. Investigations on the structures of sup(99m)Tc and 113Sn pyrophosphate complexes and of sup(99m)Tc and 113Sn ethane hydroxy diphosphate complexes

    International Nuclear Information System (INIS)

    Hohloch, M.

    1980-01-01

    The complex formation of double labelling of bivalent 113 Sn and reduced, quadrovalent sup(99m)Tc with pyrophosphate (PPi) or ethane hydroxy diphosphorate (EHDP) has been investigated by means of in vivo distribution in the rat. The molar rates of sup(99m)Tc and 113 Sn to PPi resp. EHDP, as well as the pH-value and the initial concentration is varied. Furthermore, both elements were oxidized with H 2 O 2 in the alkaline medium. Four typical sup(99m)Tc and two typical 113 Sn in-vivo distribution patterns can be differentiated: 1. Pertechnetate, characterized by a strong enrichment in the stomach, forms when all Sn-II has been oxidized to Sn-IV in the preparation. 2. One bone-seeking 113 Sn-II PPi (EHDP) complex and a sup(99m)Tc-IV PPi (EHDP) complex each, which are formed at least equimolar ratio of Sn to PPi (EHDP) and suffiently high concentration of PPi (EHDP) in the physiological pH-value. 3. A non-bone-seeking sup(99m)Tc-IV compound, which is enriched in the kidneys instead, is formed in the weakly alkaline medium or at low PPi (EHDP) concentration. This is probably monomeric technetium dioxide dihydrate. 4. A sup(99m)Tc as well as a Sn colloid is formed at deficient ligand concentration (PPi or EHDP to Sn). The chemical composition of the complexes is discussed the possible reaction courses are illustrated in the following diagrams. (orig./MG) [de

  15. Scintigraphic evaluation of chronic cholecystitis with cholelithiasis using technetium-99m-labelled pyridoxylidene isoleucine

    International Nuclear Information System (INIS)

    Alp, E.; Bekdik, C.F.; Laleli, Y.; Ercan, M.T.

    1981-01-01

    Technetium-99m-labelled pyridoxylidene isoleucine was evaluated in normal subjects as a hepatobiliar scanning agent and in patients with chronic cholecystitis with cholelithiasis. In all the normals and patients the liver function tests (SGOT, SGPT, AP and serum bilirubin) were normal. Scintigraphic studies were performed at 5, 10, 15, 20, 25, 30 and 60 min after IV administration of the agent. In the normal group (seven subjects) liver was visualized at 5 min, the common bile duct and the gall bladder at 5-15 min and the bowel activity within 20 min. In the patient group (15 subjects) the liver and the common bile duct were visualized at the same time as in the normal group but the gall bladder was either visualized later or not at all. The results showed that chronic cholecystitis with cholelithiasis may be diagnosed with 87% accuracy using 99 Tcsup(m)-pyridoxylidene isoleucine cholescintigraphy. Scintigraphy with this agent has also superiority over roentgenologic examination in 20% of the cases. (author)

  16. Thermal lens study of thermo-optical properties and concentration quenching of Er3+-doped lead pyrophosphate based glasses

    Energy Technology Data Exchange (ETDEWEB)

    Santos, C. C. [Universidade Federal do Ceara, Ceara, Brazil; Rocha, U. [Grupo de Fotônica e Fluidos Complexos, Instituto de Física, Brazil; Guedes, Ilde [Universidade Federal do Ceara, Ceara, Brazil; Vermelho, M. V. D. [Instituto de Fisica, Universidade Federal de Alagoas, Brazil; Boatner, Lynn A [ORNL; Jacinto, C. [Instituto de Fisica, Universidade Federal de Alagoas, Brazil

    2012-01-01

    In this work, we have used the thermal lens technique combined with conventional spectroscopy to characterize the thermo-optical properties of Er3+-doped lead pyrophosphate-based glasses. More precisely, we have investigated and quantified experimentally the fluorescence quantum efficiencies of the Er3+ levels, and we describe the role of concentration quenching effects. The fluorescence quantum efficiency of the 4I13/2 level is very high when compared to other phosphate glasses, while that of the green-coupled levels is very small. Other important photonic materials parameters, such as the thermal diffusivity and temperature coefficient of the optical path length change, were obtained and compared with those of other glass systems. The cumulative results obtained here for the Er-doped lead pyrophosphate glass show that this material is a good candidate for photonic applications with a characteristic Er3+ infrared emission around 1550 nm.

  17. The sorption of uranium and technetium on bentonite, tuff and granodiorite

    International Nuclear Information System (INIS)

    Baston, G.M.N.; Berry, J.A.; Brownsword, M.; Cowper, M.M.; Heath, T.G.; Tweed, C.J.

    1995-01-01

    A combined experimental and modeling study of the sorption of uranium and technetium on geological materials has been carried out as part of the PNC program to increase confidence in the performance assessment for a high-level radioactive waste (HLW) repository in Japan. Batch sorption experiments have been performed in order to study the sorption of uranium and technetium onto bentonite, tuff and granodiorite from both equilibrated seawater and de-ionized water under strongly-reducing and non-reducing conditions. A preliminary study of the sorption of uranium on mineral surfaces in granodiorite has also been undertaken using a nuclear microprobe. Mathematical modeling using the geochemical speciation program HARPHRQ in conjunction with the HATCHES database has been carried out in order to interpret the results of the sorption experiments

  18. Experimental substantiation of myocardial affection visualization by means of pyrophosphate-sup(99m)Tc

    Energy Technology Data Exchange (ETDEWEB)

    Shepeleva, I I; Saprygin, D B; Saks, V A; Kramer, A A; Kashtelyan, L S [Akademiya Meditsinskikh Nauk SSSR, Moscow. Vsesoyuznyj Kardiologicheskij Nauchnyj Tsentr; Akademiya Meditsinskikh Nauk SSSR, Moscow. Inst. Serdechno-Sosudistoj Khirurgii)

    1979-03-01

    To study the mechanisms of accumulation of the pyrophosphate-sup(99m)TcSn complex a model of an isolated rat heart perfused according to Langendorf under conditions was used. The results of the experiment showed that intensive accumulation of the radionuclide in the myocardium began already at the first minutes of anoxia, i.e. at the stage of reversible changes when reoxygenation brought about a drop in the level of accumulated radioactivity down to the normal limit. Anoxia lasting for 5 minutes led to a 10 per cent accumulation of the entire dose of radioactivity in the myocardium, that lasting for 10 minutes-up to 18 per cent. As a result of a 5-minute reoxygenation after a 10-minute anoxia the level of accumulated radioactivity fell down to 4-5 per cent. Reoxygenation after s 20-30-minute anoxia produced no effect on the curve of the radionuclide accumulation in the heart. Alongside radiometric studies the content of macroergs (ATP and creatine phosphate) in the norm and in development of anoxia was determined. The accumulation of the pyrophosphate-sup(99m)TcSn complex in the myocardial cells is closely connected with energy metabolism of the cell and, is apparently, caused by changes in the cell membrane permeability by this complex.

  19. Sorption of technetium on composite chitosan-hydroxyapatite from aqueous solutions

    International Nuclear Information System (INIS)

    Pivarciova, L.; Rosskopfova, O.; Galambos, M.; Rajec, P.

    2013-01-01

    Biomaterials such as natural polymers (chitosan) and hydroxyapatite have an important application in material for bone replacement. Most of chitosan/hydroxyapatite composites are prepared by mixing hydroxyapatite particles with chitosan matrices. Another method of preparation of chitosan/hydroxyapatite composite is in-situ generation of nano-hydroxyapatite in chitosan matrix. The most common biomaterial used in the past years in hard tissue regeneration was hydroxyapatite, owing to its properties as biocompatibility, bioactivity, non-toxicity, non-immunogenicity etc. Chitosan is a polyaminosacharide, partially deacetylated product of chitin. Chitosan can be used in combination with other materials to enhance bone growth such as bone filling paste. The aims of this work were: the influence of the contact time on sorption of pertechnate anions on chitosan/hydroxyapatite composites; the effect of pH on sorption of pertechnate anions on chitosan/hydroxyapatite composites; the effect of foreign ions on sorption of pertechnate anions on chitosan/hydroxyapatite composites. The author concluded: the percentage of technetium sorption after 1 hour of contact time was > 97 %. In the initial pH range of 2.9-10.2, the percentage of technetium sorption on chitosan/hydroxyapatite composites CH/HA(A), CH/HA(B), CH/HA 30:70, ZCH was > 98 % and on CH/HA 50:50 was > 94%. The competition effect of Fe 2+ towards TcO 4 :- sorption is stronger than competition effect of other observed cations for all examined composites with the same weight ratio. The percentage of the technetium sorption was the same for all composites with the weight ratio of 30:70. (authors)

  20. Effects of concurrent drug therapy on technetium /sup 99m/Tc gluceptate biodistribution

    International Nuclear Information System (INIS)

    Hinkle, G.H.; Basmadjian, G.P.; Peek, C.; Barker, K.K.; Ice, R.D.

    1982-01-01

    Drug interactions with /sup 99m/Tc gluceptate resulting in altered biodistribution were studied using chart review and animal tests. Charts of nine patients who had abnormal gallbladder uptake of technetium /sup 99m/Tc gluceptate during a two-year period were reviewed to obtain data such as concurrent drug therapy, primary diagnosis, and laboratory values. Adult New Zealand white rabbits were then used for testing the biodistribution of technetium /sup 99m/Tc gluceptate when administered concurrently with possibly interacting drugs identified in the chart review--penicillamine, penicillin G potassium, penicillin V potassium, acetaminophen, and trimethoprim-sulfamethoxazole. Chart review revealed no conclusive patterns of altered biodistribution associated with other factors. The data did suggest the possibility that the five drugs listed above might cause increased hepatobiliary clearance of the radiopharmaceutical. Animal tests showed that i.v. penicillamine caused substantial distribution of radioactivity into the gallbladder and small bowel. Minimally increased gallbladder radioactivity occurred when oral acetaminophen and trimethoprim-sulfamethoxazole were administered concurrently. Oral and i.v. penicillins did not increase gallbladder activity. Penicillamine may cause substantial alteration of the biodistribution of technetium /sup 99m/Tc gluceptate

  1. Study of the electrochemical behaviour of technetium on mercury in an acetic buffer medium

    International Nuclear Information System (INIS)

    Courson, Olivier

    1997-01-01

    Technetium 99, produced with a high yield as fission product of 235 U in nuclear reactors constitutes an important issue in the nuclear waste management. The rich and complex solution chemistry leads up to now to an insufficient knowledge of its behaviour in PUREX process and in environment. In order to understand the reduction mechanism of pertechnetate on mercury electrode, we have developed electrochemical techniques which use an additional time parameter to classical techniques used on mercury electrode. On micro-electrode, we have observed, for long time measurements (3D polarography), a split of the first polarographic wave into two waves, which characterizes the reduction of Tc(VII) in Tc(III) as well as a modification of the catalytic peak associated with technetium metal formation. moreover, differential capacitance determination of electrode/solution interface brings to the fore the existence of species (Tc(IV), T(0)) on mercury in the reduction zone corresponding to the following reductions: Tc(VII) -> T(III) and T(III) -> Tc(0). Moreover the Tc(III)/Tc(0) reduction brings the intermediary Tc(I) and Tc(II) which are present only for rates faster than the scan. Results obtained on microelectrodes have been confirmed on macro-electrode; the insoluble species Tc(IV) and Tc are formed during the reduction of Tc(VII) on metal. Thus, in acetate buffer media (pH=4.6), the pertechnetate reduction is characterized by the presence of absorbable species (Tc O 2 hydrated,Tc). Moreover, the different electrochemical responses obtained with our techniques like 3D-polarography (waves and catalytic peaks) can be attributed to the following steps: Tc(VII)->Tc(V), Tc(IV) -> Tc(III), Tc(III) -> Tc(I) and Tc(I) -> Tc(0). The Tc(V) formation is followed by the rapid disproportionation of Tc(V) and Tc(VI) and Tc(I) reduction is associated with the proton reduction. (author)

  2. Detection of acute inflammatory bowel disease with Tc-99m-HSA-sucralfate scans

    International Nuclear Information System (INIS)

    Yip, T.C.; Houle, S.; Jeejeebhoy, K.N.

    1987-01-01

    Sucralfate binds to mucosal ulcerations. Twelve studies were performed in 11 patients with inflammatory bowel disease. Technetium-sucralfate was prepared in vitro and given orally. Images were obtained at 4-6, 24, and 48 hours. Persistent focal abnormalities or activity in the large bowel beyond 48 hours was interpreted as positive. Patients' charts were reviewed. Technetium-sucralfate was positive in ten of ten studies in nine patients with active disease, one with equivocal activity, and negative in one patient with inactive disease. Nine of 19 abnormal sites were detected with technetium-sucralfate and radiology or endoscopy; six of ten were detected with technetium-sucralfate only. Technetium-sucralfate is very sensitive in detecting active inflammatory bowel disease in individual patients

  3. Determination of technetium-99 in environmental samples: A review

    International Nuclear Information System (INIS)

    Shi Keliang; Hou Xiaolin; Roos, Per; Wu Wangsuo

    2012-01-01

    Highlights: ► The source term, physicochemical properties, environmental distribution and behaviour of 99 Tc are presented. ► Various sample pre-treatment and pre-concentration techniques of technetium are discussed. ► Chemical separation and purification techniques for 99 Tc in environmental samples are reviewed. ► Measurement techniques for 99 Tc in environmental level and automated analytical methods are reviewed. ► The reported analytical methods of 99 Tc are critically compared to provide overall information. - Abstract: Due to the lack of a stable technetium isotope, and the high mobility and long half-life, 99 Tc is considered to be one of the most important radionuclides in safety assessment of environmental radioactivity as well as nuclear waste management. 99 Tc is also an important tracer for oceanographic research due to the high technetium solubility in seawater as TcO 4 − . A number of analytical methods, using chemical separation combined with radiometric and mass spectrometric measurement techniques, have been developed over the past decades for determination of 99 Tc in different environmental samples. This article summarizes and compares recently reported chemical separation procedures and measurement methods for determination of 99 Tc. Due to the extremely low concentration of 99 Tc in environmental samples, the sample preparation, pre-concentration, chemical separation and purification for removal of the interferences for detection of 99 Tc are the most important issues governing the accurate determination of 99 Tc. These aspects are discussed in detail in this article. Meanwhile, the different measurement techniques for 99 Tc are also compared with respect to advantages and drawbacks. Novel automated analytical methods for rapid determination of 99 Tc using solid extraction or ion exchange chromatography for separation of 99 Tc, employing flow injection or sequential injection approaches are also discussed.

  4. Biomedical tracers: technetium-99 m complexing sulfur polydentate ligands

    International Nuclear Information System (INIS)

    Bendennoune, A.

    1994-01-01

    Cyclic and acyclic tetra sulfur ligands have been synthesized and some of them have been labelled with technetium-99m. These works have two different aims: 1- Development of methods permitting to obtain easily potential technetium complexing sulfur polydentate chelates. 2- Research of positive and neutral complexes of this metal likely to replace thalium-201 in the coronary flow estimation and [TcO-HMPAO] sup 0 complex in the cerebral scintigraphy, respectively. In this work, first, different ways for obtaining dithioetherdithiols and cyclic tetrathioethers containing functional groups have been carried out, then complexation of the core of nitrutechnetium (TcN) sup 2+ at tracers scale, by dithioetherdithiols, using exchange reaction with [sup 9 sup 9 sup m TcNCl sub 4 ] sup - ion complex or sup 99 sup m TcN Cl sub 2 [P(CH sub 2 CH sub 2 CN) sub 3 ] sub 2 has been studied. Finally, biological distribution in swiss mouse of these technetiated complexes has been studied. 135 refs., 30 figs., 13 tabs. (F.M.)

  5. Analysis of americium, plutonium and technetium solubility in groundwater

    International Nuclear Information System (INIS)

    Takeda, Seiji

    1999-08-01

    Safety assessments for geologic disposal of radioactive waste generally use solubilities of radioactive elements as the parameter restricting the dissolution of the elements from a waste matrix. This study evaluated americium, plutonium and technetium solubilities under a variety of geochemical conditions using the geochemical model EQ3/6. Thermodynamic data of elements used in the analysis were provided in the JAERI-data base. Chemical properties of both natural groundwater and interstitial water in buffer materials (bentonite and concrete) were investigated to determine the variations in Eh, pH and ligand concentrations (CO 3 2- , F - , PO 4 3- , SO 4 2- , NO 3 - and NH 4 + ). These properties can play an important role in the complexation of radioactive elements. Effect of the groundwater chemical properties on the solubility and formation of chemical species for americium, plutonium and technetium was predicted based on the solubility analyses under a variety of geochemical conditions. The solubility and speciation of the radioactive elements were estimated, taking into account the possible range of chemical compositions determined from the groundwater investigation. (author)

  6. Evaluation of reflux oesophagitis with technetium-99m-labelled ...

    African Journals Online (AJOL)

    Sucralfate binds with denuded protein to form a stable complex to protect the damaged mucosa. By utilising this property, technetium-99m-labelled sucraJfate can be used to demonstrate ulceration in the upper gastro-intestinal tract. Aim: The aim of this study was to evaluate 99mTc-labelled sucralfate in the diagnosis of ...

  7. Membrane-based separation technologies for cesium, strontium, and technetium

    International Nuclear Information System (INIS)

    Kafka, T.

    1996-01-01

    This work is one of two parallel projects that are part of an ESP task to develop high-capacity, selective, solid extractants for cesium, strontium, and technetium from nuclear wastes. In this subtask, Pacific Northwest National Laboratory (PNNL) is collaborating with 3M, St. Paul, Minnesota, working in cooperation with IBC Advanced Technologies, American Fork, Utah

  8. Prospective evaluation of radionuclide scanning in detection of intestinal necrosis in neonatal necrotizing enterocolitis

    International Nuclear Information System (INIS)

    Haase, G.M.; Sfakianakis, G.N.; Lobe, T.E.; Boles, E.T.

    1981-01-01

    The ability of external imaging to demonstrate intestinal infarction in neonatal necrotizing enterocolitis (NEC) was prospectively evaluated. The radiopharmaceutical technetium--99m diphosphonate was injected intravenously and the patients subsequently underwent abdominal scanning. Clinical patient care and interpretation of the images were entirely independent throughout the study. Of 33 studies, 7 were positive, 4 were suspicious, and 22 were negative. One false positive study detected ischemia without transmural infarction. The second false positive scan occurred postoperatively and was due to misinterpretation of the hyperactivity along the surgical incision. None of the suspicious cases had damaged bowel. The two false negative studies clearly failed to demonstrate frank intestinal necrosis. The presence of very small areas of infarction, errors in technical settings, subjective interpretation of scans and delayed clearance of the radionuclide in a critically ill neonate may all limit the accuracy of external abdominal scanning. However, in spite of an error rate of 12%, it is likely that this technique will enhance the present clinical, laboratory, and radiologic parameters of patient management in NEC

  9. Technetium-99m-labeled annexin V imaging for detecting prosthetic joint infection in a rabbit model.

    Science.gov (United States)

    Tang, Cheng; Wang, Feng; Hou, Yanjie; Lu, Shanshan; Tian, Wei; Xu, Yan; Jin, Chengzhe; Wang, Liming

    2015-05-01

    Accurate and timely diagnosis of prosthetic joint infection is essential to initiate early treatment and achieve a favorable outcome. In this study, we used a rabbit model to assess the feasibility of technetium-99m-labeled annexin V for detecting prosthetic joint infection. Right knee arthroplasty was performed on 24 New Zealand rabbits. After surgery, methicillin-susceptible Staphylococcus aureus was intra-articularly injected to create a model of prosthetic joint infection (the infected group, n = 12). Rabbits in the control group were injected with sterile saline (n = 12). Seven and 21 days after surgery, technetium-99m-labeled annexin V imaging was performed in 6 rabbits of each group. Images were acquired 1 and 4 hours after injection of technetium-99m-labeled annexin V (150 MBq). The operated-to-normal-knee activity ratios were calculated for quantitative analysis. Seven days after surgery, increased technetium-99m-labeled annexin V uptake was observed in all cases. However, at 21 days a notable decrease was found in the control group, but not in the infected group. The operated-to-normal-knee activity ratios of the infected group were 1.84 ± 0.29 in the early phase and 2.19 ± 0.34 in the delay phase, both of which were significantly higher than those of the control group (P = 0.03 and P = 0.02). The receiver operator characteristic curve analysis showed that the operated-to-normal-knee activity ratios of the delay phase at 21 days was the best indicator, with an accuracy of 80%. In conclusion, technetium-99m-labeled annexin V imaging could effectively distinguish an infected prosthetic joint from an uninfected prosthetic joint in a rabbit model.

  10. Clinical evaluation of technetium-99m infecton for the localisation of bacterial infection

    International Nuclear Information System (INIS)

    Britton, K.E.; Vinjamuri, S.; Hall, A.V.; Solanki, K.; Siraj, Q.H.; Bomanji, J.; Das, S.

    1997-01-01

    The aim of the study was to distinguish infection from inflammation in patients with suspected infection using technetium-99m Infecton. Ninety-nine patients (102 studies) referred for infection evaluation underwent imaging with 400 MBq 99m Tc-Infecton at 1 and 4 h. Most patients had appropriate microbiological tests and about half (56) had radiolabelled white cell scans as well. No adverse effects were noted in any patient. The clinical efficacy of 99m Tc-Infecton depended in part on whether imaging was undertaken during antibiotic therapy for infection or not. In consultation with the microbiologist, 5-14 days of appropriate and successful antibiotic therapy was considered adequate to classify some results as true-negatives. The figures for sensitivity and specificity of 99m Tc-Infecton for active or unsuccessfully treated infection were 83% and 91% respectively. It is concluded that 99m Tc-Infecton imaging contributed to the differential diagnosis of inflammation. It is being used as the first imaging modality when bacterial infection is suspected. (orig.). With 2 figs., 1 tab

  11. 3. Congress of the SA Society of nuclear medicine: Technetium-99m technology

    International Nuclear Information System (INIS)

    Beyers, M.

    1988-08-01

    The Atomic Energy Corporation of SA Limited have been engaged in the manufacture of radioisotopes since 1967, shortly after the SAFARI-1 reactor at Pelindaba was commissioned. Since then the use of radioisotopes in South Africa has grown rapidly and at present 95% of the in vivo diagnostic radioisotopes (radiopharmaceuticals) utilized in nuclear medicine are manufactured locally. Because radioisotopes are applied mainly in sophisticated chemically or mechanically processed forms, production requires not only a skilled production team, but also the appropriate facilities for the manufacture of high-quality products which comply with the necessary safety standards. Compliance with such standards is especially important for the routine production of radiopharmaceuticals for use in nuclear medicine. Over the past 20 years technetium-99m has achieved a dominant position among the diagnostic tools in modern nuclear medicine.The scope of nuclear medicine is expanding continuously and its future lies primarily in the development of new organspecific technetium-99m radiodiagnostic agents. Many improvements and changes have been made to Tc-99m generators, the major source of Tc-99m, since they were introduced to nuclear medicine in the late 1950's. The new Peltek-F sterile Tc-99m generator developed by the Isotope Production Centre is a symbol of progress made. In order to commemorate the launching of the new Peltek-F technetium-99m generator during August 1988 it was decided to publish six papers that were presented at the Third Congress of the Society of Nuclear Medicine held at Bloemfontein during the period 15 - 17 August 1988 by members of the Isotope Production Centre. This will serve as a useful reference on various aspects of technetium-99m technology and will stimulate the use of this product as well as new research in this field

  12. Redox Additive-Improved Electrochemically and Structurally Robust Binder-Free Nickel Pyrophosphate Nanorods as Superior Cathode for Hybrid Supercapacitors.

    Science.gov (United States)

    Sankar, Kalimuthu Vijaya; Seo, Youngho; Lee, Su Chan; Chan Jun, Seong

    2018-03-07

    For several decades, one of the great challenges for constructing a high-energy supercapacitor has been designing electrode materials with high performance. Herein, we report for the first time to our knowledge a novel hybrid supercapacitor composed of battery-type nickel pyrophosphate one-dimensional (1D) nanorods and capacitive-type N-doped reduced graphene oxide as the cathode and anode, respectively, in an aqueous redox-added electrolyte. More importantly, ex situ microscopic images of the nickel pyrophosphate 1D nanorods revealed that the presence of the battery-type redox additive enhanced the charge storage capacity and cycling life as a result of the microstructure stability. The nickel pyrophosphate 1D nanorods exhibited their maximum specific capacitance (8120 mF cm -2 at 5 mV s -1 ) and energy density (0.22 mWh cm -2 at a power density of 1.375 mW cm -2 ) in 1 M KOH + 75 mg K 3 [Fe(CN) 6 ] electrolyte. On the other side, the N-doped reduced graphene oxide delivered an excellent electrochemical performance, demonstrating that it was an appropriate anode. A hybrid supercapacitor showed a high specific capacitance (224 F g -1 at a current density of 1 A g -1 ) and high energy density (70 Wh kg -1 at a power density of 750 W kg -1 ), as well as a long cycle life (a Coulombic efficiency of 96% over 5000 cycles), which was a higher performance than most of those in recent reports. Our results suggested that the materials and redox additive in this novel design hold great promise for potential applications in a next-generation hybrid supercapacitor.

  13. The use of technetium-99m hexamethylpropylene amine oxime labelled white blood cells to detect subclinical inflammation of the heart after cardiopulmonary bypass in children with congenital heart disease

    International Nuclear Information System (INIS)

    Kao Chiahung; Wang Yenliang; Wang Shyhjen; Hsieh Kaisheng

    1992-01-01

    Ten children (6 boys and 4 girls, aged 1-9 years old) underwent operations with a cardiopulmonary bypass, and the technetium-99m hexamehtylpropylene amine oxine ( 99m Tc-HMPAO) labelled white blood cell (WBC) heart scans were used to detect postoperative leukocyte infiltration in the hearts. The results showed that 80% (8/10) of the cases had subclinical inflammation in the hearts (grading of WBC scans ≥score 2), and a positive correlation (R=0.77) was noted between the severity of the inflammation (grading of the WBC scans) and the duration of the cardiopulmonary bypass in the operations. Another control group (9 boys and 2 girls, aged 2-13 years old) underwent operations without a cardiopulmonary bypass, and subclinical inflammation of hearts was demonstrated in only 1 case (9%) by the 99m Tc-HMPAO labelled WBC scans (grading of WBC scans 99m Tc-HMPAO labelled WBC heart scans may provide non-invasive and directly discernible evidence of subclinical inflammation in the heart due to a transient ischaemic state during a cardiopulmonary bypass, even if the clinical symptoms and signs of carditis are not apparent. (orig.)

  14. Preoperative localization of parathyroid adenomas by technetium and thallium double-labeling scintigraphy. Difficulties linked to associated thyroid lesions

    International Nuclear Information System (INIS)

    Valensi, P.; Attali, J.R.; Sebaoun, J.; Bedig, G.; Paycha, F.; Tellier, P.; Vulpillat, M.; Sarfati, E.; Dubost, C.

    1989-01-01

    Technetium and thallium double-labeling scintigraphy with image subtraction was carried out on 63 patients suspected of having primary hyperparathyroidism, with or without thyroid involvement. Forty-four patients had a normal thyroid image with technetium. The positive foci located by double-labeling in patients who were to undergo surgery always coincided with parathyroid adenoma. In the 16 cases where the initial diagnosis of hyperparathyroidism was not substantiated, the double-labeling test was normal. Thus for these 44 patients, scintigraphy sensitivity was 75% and specificity was 100%. Nineteen patients had an abnormal thyroid image with technetium. In 7 cases, image subtraction following double-labeling yielded uninterpretable data. In 12 other patients, the positive foci located outside the thyroid by double-labeling coincided with a parathyroid adenoma, whereas this was true for only one patient whose positive foci were located inside the thyroid; a parathyroid adenoma was not detected preoperatively in 4 patients. This double-labeling test is thus useful in locating parathyroid adenomas when technetium scintigraphy of the thyroid is normal; when it is abnormal, double-labeling is advantageous only in cases of extrathyroid foci [fr

  15. A neutral lipophilic technetium-99m complex for regional cerebral blood flow imaging

    International Nuclear Information System (INIS)

    Narra, R.K.; Nunn, A.D.; Kuczynski, B.L.; DiRocco, R.J.; Feld, T.; Silva, D.A.; Eckelman, W.C.

    1990-01-01

    Technetium-99m-DMG-2MP (Chloro[bis[2,3-butanedionedioxime(1-)-0][2,3- butanedionedioximato (2-)-N,N',N double-prime,N'double-prime,N double-prime double-prime,N'double-prime double-prime] (2-methylpropyl borato (2-))technetium]), also known as SQ 32097 is a member of a family of neutral lipophilic compounds generally known as boronic acid adducts of technetium dioxime complexes (BATOs). After i.v. administration, the concentration of [ 99m Tc]DMG-2MP in various regions of the brain appears to be proportional to blood flow. In rats, 1.1% ID was in the brain at 5 min postinjection when the blood contained less than 3% ID. Over 24 hr excretion was 59% in the feces and 23% in the urine. The activity in monkey brain at 5 min was 2.8% ID and it cleared with a t1/2 of 86 min. Autoradiographs of monkey brain sections showed excellent regional detail with a gray/white ratio of 3.6 at 10 min. The distribution of [ 99m Tc]DMG-2MP in the monkey brain corresponds to the known cytoarchitectural pattern of cerebral glucose metabolism. The properties of [ 99m Tc]DMG-2MP make it a potentially useful agent for cerebral perfusion imaging in man

  16. Technetium-99m labeled radiodiagnostic agents and method of preparation

    International Nuclear Information System (INIS)

    1976-01-01

    A method of preparing improved technetium-99m labelled radiodiagnostic agents by reducing sup(99m)Tc-pertechnetate with stannous tartrate is given. Human serum albumine (HSA) and 1-hydroxyethylidene-1,1-disodiumphosphonate (HEDSPA), which are useful in scintigraphic examinations of the lung and bone, were labelled in this way

  17. Fast technetium Eigen-colloid determination: preparative CPC combined with suspension liquid scintillation

    International Nuclear Information System (INIS)

    Breynaert, E.; Maes, A.

    2005-01-01

    Full text of publication follows: Both medical and environmental studies concerned with the solubility and the complexation chemistry of technetium have encountered colloidal Tc(IV)-forms. Although the existence of the Tc colloids has been proven by various techniques [1-6], their determination still remains an issue. Recently a Column Precipitation Chromatography (CPC) technique was developed which enabled the quantitative determination of technetium Eigen-colloids. Based on this technique, a solid phase extraction (SPE)-like methodology was developed that can be used in combination with suspension liquid scintillation to provide a fast analysis of the Eigen-colloid content of a sample. The CPC technique is a thorough analysis methodology for the quantitative determination of the Eigen-colloid content of a sample containing reduced technetium species. This technique requires a relative long elution scheme and fractionation of the eluate. The fractionation also implies a relatively long counting time to determine the Eigen-colloid activity of a sample. Currently an SPE-like analysis methodology was developed which combines a good estimate of the Eigen-colloid content with fast analysis times. To construct a methodology providing both features a specialized extraction apparatus was constructed and a quantitative suspension liquid scintillation technique was developed. This combination enables the Eigen-colloid determination within a short experimental time (15 min) and a limited counting time (60 min). The authors acknowledge a grant from KULeuven University and financial support from the KULeuven Geconcerteerde Onderzoeksacties (GOA2000/007). We also kindly acknowledge NIRAS/ONDRAF for financial support from Contract CCHO 20004004862 [1] Grossmann, B. and R. Muenze, Relationship between complex formation by 99 Tc(IV) and the chemical structure of aliphatic carboxylic acid ligands. The International Journal of Applied Radiation and Isotopes, 1982. 33(3): p. 189

  18. Radiopharmacokinetic data for 99mTc-ABP - A new radiopharmaceutical for bone scanning: Comparison with 99mTc-MDP

    International Nuclear Information System (INIS)

    Murphy, Consuelo Arteaga de; Melendez-Alafort, Laura; Montoya-Molina, Carlos E.; Sepulveda-Mendez, Jesus

    1997-01-01

    Technetium-99m-labeled alendronate is a new radiopharmaceutical for bone scanning developed under strict quality control at the INNSZ. The purpose of this work was to compare the radiopharmacokinetic data and the dosimetry of 99m Tc-ABP and 99m Tc-MDP in 10 volunteers, after it was tested in laboratory animals. 99m Tc-ABP has shorter mean residence time (MRT) and t (1(2)) β; is less protein bound; has a higher renal clearance; smaller Vdss, and similar bone uptake at 1 and 2 h. 99m Tc-ABP gives less radiation exposure to the patient with a 740 MBq dose, and the quality of the bone scan is excellent. 99m Tc-ABP is a better radiopharmaceutical than 99m Tc-MDP for bone scanning

  19. Abnormal extraosseous activity in both lungs and stomach in pre-transplant 99mTc-MDP bone scan disappearing after renal transplant

    International Nuclear Information System (INIS)

    Sonavane, Sunita Tarsarya; Marwah, Atul; Jaiswar, Rajnath; Shah, Hardik

    2013-01-01

    A chronic kidney disease male patient presenting with bone pains, fever, weakness, and clinically ascites was subjected to four technetium-99m-methylene diphosphonate ( 99m Tc-MDP) bone scans, two before renal transplant and two after renal transplants. Pretransplant bone scan revealed metabolic bone disease with focal insufficiency fractures. Marked extraosseous activity in both lungs and stomach was also visualized. On regular hemodialysis (HD) after 4 months, repeat pretransplant bone scan showed persistent uptake in lungs and stomach, representing altered calcium metabolism with microcalcifications. He underwent human leukocyte antigen (HLA) matched live donor renal transplantation, started on immune-suppression and steroids. Posttransplant bone scan at 20 days revealed no definite interval change, but bone scan performed approximately 17 months posttransplant showed resolving metabolic bone disease and the tracer uptake in the lungs and stomach was no more visualized. Patient clinically followed-up until the date (February 2013) is asymptomatic with serum creatinine of 1.5 mg/dl, no bone scan done. (author)

  20. Scintigraphy with /sup 111/In-labeled antimyosin F(ab)/sub 2/ monoclonal antibody and /sup 99m/Tc-pyrophosphate in rhabdomyolysis

    Energy Technology Data Exchange (ETDEWEB)

    Krause, T.; Schuemichen, C.; Hohenloser, S.; Kasper, W.; Meinertz, T.

    1988-02-01

    A report is presented of the scintigraphic diagnosis of a generalized rhabdomyolysis with myocardial involvement using /sup 111/In labelled antimyosin F(ab)/sub 2/ monoclonal antibodies as compared to /sup 99m/Tc pyrophosphate.

  1. Advances in technetium chemistry towards 99mTc receptor imaging agents

    International Nuclear Information System (INIS)

    Johannsen, B.; Spies, H.

    1997-01-01

    The development of the chemistry of technetium and its non-radioactive surrogate rhenium has been prompted by the trends and needs of nuclear medicine, which predominantly uses 99m Tc radiopharmaceuticals for a broad range of diagnostics. Technetium-99m is the ideal radioisotope for tomographic single-photon emission tomography (SPECT) imaging due to its nuclear properties (6.2 h, E γ 140 keV) and ready availability through generator systems. Transition metals offer many opportunities for designing molecules by modifying the environment around the core, allowing certain biological properties to be imposed upon the molecule. Whereas research in the past was mainly concerned with biological properties that allow relatively unspecific functional imaging, as in brain or myocardium perfusion studies, nuclear medicine is now requiring more and more biochemical information on low capacity, high specificity targets. Many research groups have become involved in the search for new technetium-based compounds, called the third generation of 99m Tc radiopharmaceuticals, that employ the principles of modern pharmacology to achieve biochemical specificity. There has been considerable interest in imaging CNS and other receptors with 99m Tc receptor-binding ligands. Such a 99m Tc CNS receptor-imaging agent is currently not yet in use because of the significant hurdles to be overcome in attaining this ambitious goal. However, some Tc and Re complexes of remarkable affinity in vitro, and the first high-affinity 99m Tc probes able to label the dopamine transporter in the brain by SPECT imaging prove the feasibility of this approach. (Author)

  2. Technetium-99m-Sestamibi in the diagnosis of acute chest pain

    International Nuclear Information System (INIS)

    Gilleece, T.; Salehi, N.; Better, N.

    1998-01-01

    Full text: A 45-year-old male was admitted to coronary care with a two-day history of recurrent chest pain. Despite maximal medical therapy, pain persisted. Examination and ECG with pain, were normal, suspicion of ischaemia was moderately high but coronary angiography was not immediately available. Technetium-99m-Sestamibi was prepared at the start of the day according to the standard preparation protocol (Du Pont). Coronary Care informed the Nuclear Medicine Department immediately the patient experienced a further episode of chest pain. Technetium-99m-Sestamibi was administered in coronary care, 4.30 minutes after being advised of the onset of further chest pain. Images were acquired 60 minute post-injection; 15 minutes after the patient had been given 200 mL of milk. A triple-headed gamma camera was used to acquire SPECT images over a 1200 arc, 30 frames of 30 seconds using a 64 x 64 matrix. The patient was laying prone with arms raised out of the field of view. Images showed a normal distribution of technetium-99m -Sestamibi throughout the myocardium. Due to ongoing clinical suspicion by the treating physician, coronary angiography was subsequently performed. This showed normal coronary arteries. Medical therapy was ceased and the patient discharged the next day. We concluded that the chest pain at the time of injection was not ischaemic. Previous trials had shown a 95% sensitivity for this method of diagnosing ischaemia. This method permits a novel and simple technique for diagnosing myocardial ischaemia and obviating the need for cardiac catheterization in this group of patients

  3. Effect of mitomycin-c on biodistribution of 99 mTc-sodium pyrophosphate radiopharmaceuticals in mice; Efeito da mitomicina-c na biodistribuicao do radiofarmaco pirofosfato de sodio marcado com Tecnecio-99m em camundongos

    Energy Technology Data Exchange (ETDEWEB)

    Gomes, Maria L.; Braga, Ana C.S.; Gutfilen, Bianca; Bernardo-Filho, Mario [Instituto Nacional do Cancer, Rio de Janeiro, RJ (Brazil)

    1997-12-01

    The desirable characteristics of technetium-99 have stimulated the development of labeling techniques for different molecular and cellular. It is generally acceptable that a variety of factors other than disease can alter the biodistribution of radiopharmaceutical and one such factor is the drug therapy. The absence of knowledge of these factors may result in an unexpected behavior of the radiopharmaceutical. Since patients on chemotherapeutic treatment ca be submitted, for different reasons, to a nuclear medicine procedure, we have studied in mice, the effect of mitomycin-C on the biodistribution of the radiopharmaceutical {sup 99m} Tc-pyrophosphate ({sup 99m} Tc-PYP). Mitomycin-C is an antineoplastic agent obtained from Streptomyces caesptosus. It was administered 0,15 mg of mitomycin-C in Balb/c in Balb/c female mice with an interval of 72 hours. After one hour of the last dose, 0.3 ml of {sup 99m} Tc-PYP (7.4 MBq) were injected after 0.5 h the animals were sacrificed. The organs were isolated, weighted and counted in a well counter. The percentages of radioactivity per gran of organs (% rad/g) were calculated and statistics analyses were performed (wilcoxon). The results have shown that the % rad/g has increased in pancreas, stomach, bone and lungs. These increased of radioactivity can be justified by the metabolic process or the therapeutic effect of mitomycin-C. (author). 8 refs., 2 tabs.

  4. Technetium-99m sestamibi limb scintigraphy in post-traumatic reflex sympathetic dystrophy: preliminary results

    International Nuclear Information System (INIS)

    Sarikaya, A.; Firat, M.F.; Sarikaya, I.; Pekindil, G.; Pekindil, Y.

    2001-01-01

    Reflex sympathetic dystrophy (RSD) has widely variable clinical manifestations. Its pathogenesis remains partially unexplained. RSD is commonly divided into three stages; these stages are not always clearly separable, but staging remains important for correct treatment. Since the disease involves soft tissue alterations as well as bone changes, we decided to investigate whether technetium-99m sestamibi limb imaging can be used to evaluate the soft tissue appearance. Fifteen patients (seven females and eight males; age range 12-68 years) with clinically significant post-fracture RSD were evaluated with both three-phase bone scan (TPBS) and 99m Tc-sestamibi limb scintigraphy. Although, in general, patients with similar duration of disease, clinical stage and TPBS activity tended to have similar patterns of sestamibi uptake, discordant uptake patterns were observed in some patients with clinical stage 1. Thus, of 12 patients with stage I disease, eight had increased 99m Tc-sestamibi activity in the distal part of the affected limb, while three had normal activity and one had decreased activity. All three patients with stage II disease showed normal 99m Tc-sestamibi uptake. Although most of the patients with increased 99m Tc-sestamibi uptake had increased activity on all three phases of the bone scan, there were discordant results between the scan patterns in other patients. On the basis of these findings, we suggest that 99m Tc-sestamibi imaging may contribute to the differentiation between clinical stages and may permit evaluation of the disease course and selection of appropriate therapy. 99m Tc-sestamibi imaging is not, however, a primary diagnostic procedure for RSD. (orig.)

  5. Determination of technetium by total reflection x-ray fluorescence

    International Nuclear Information System (INIS)

    Bermudez, J.I.; Greaves, E.D.; Nemeth, P.

    2000-01-01

    We describe a technique using total reflection x-ray fluorescence (TXRF) for determination of Technetium produced by elution of chromatography generators with physiological saline solutions. The analysis with the 18.41 keV K α line of Technetium was accomplished with monochromatized K α radiation from a silver anode x-ray tube operated at 45 keV and 20 mA. This radiation at 22.104 keV is efficiently coupled to the 21.054 keV absorption edge of Tc. It is also of advantage in the direct analysis of organic and saline properties of the Tc-bearing samples. Quantification was accomplished by internal standard addition of Ga and using an interpolated value of the sensitivity for Tc between Molybdenum and Rhenium. Data processing was carried out with the QXAS-AXIL software package. System sensitivity was found adequate for direct Tc determination of eluted saline solutions. The interest and advantages of the use of the technique as an auxiliary in the synthesis and characterization of Tc-labeled radiopharmaceuticals used for diagnosis in nuclear medicine are discussed. Detection limits in the matrices analyzed are reported. (author)

  6. Determination of degradation conditions of exchange resins containing technetium

    International Nuclear Information System (INIS)

    Rivera S, A.; Monroy G, F.; Quintero P, E.

    2014-10-01

    The quantification of Tc-99 in spent exchange resins, coming from nuclear power plants, is indispensable to define their administration. The Tc-99 is a pure beta emitter of 210000 years of half-life, volatile and of a high mobility in water and soil. For this reason, the objective of this work is to establish a digestion method of ionic exchange resins containing technetium that retains more than 95% of this radioisotope. Mineralization tests were carried out of a resin Amberlite IRN-150 by means of an oxidation heat, in acid medium, varying the resin mass, the medium volume, the media type, the temperature and the digestion time. The digested samples were analyzed by gas chromatography to estimate the grade of their degradation. The 99m Tc was used as tracer to determine the technetium percentage recovered after mineralizing the resin. The digestion process depends on the temperature and the resin mass. At higher temperature better mineralization of samples and to greater resin mass to a constant temperature, less degradation of the resin. The spectra beta of the 99m Tc and 99 Tc are presented. (Author)

  7. Technetium compounds

    International Nuclear Information System (INIS)

    Murphy, C.A. de; Ferro F, G.

    2003-01-01

    The first radiopharmaceuticals of 99m Tc, also call of 'first generation' as colloids, aggregates and simple complexes were developed with relative easiness without it was necessary a wide understanding of its chemical structure. In the radiopharmaceuticals of 'second generation' were included those derived of the HIDA for hepatobiliary images, MAG3 and EC for images of tubular renal de purification, HMPAO and ECD for images of cerebral perfusion and MIBI and tetrofosmin for images of heart perfusion, that which implies a bigger demand in terms of the chemical knowledge. At the moment, we can affirm that the future of the radiopharmaceuticals of 99m Tc is based on the use of small and relevant biomolecules with high biological activity that allow the visualization in vivo of specific receiving sites and/or its expression in diverse pathologies. It is for it that with the 'third generation' is necessary a wide one knowledge of the chemistry of the technetium that allows the design and characterization of highly specific bio complexes. In this book, although focused mainly to the chemistry of the Tc, a brief revision is also presented on the main biologically active molecules that, coordinated the 99m Tc, present a high recognition In vivo for specific receivers. (Author)

  8. Technetium-99m-human fibrinogen

    International Nuclear Information System (INIS)

    Wong, D.W.; Mishkin, F.S.

    1975-01-01

    Exogenous fibrinogen has been successfully labeled with /sup 99m/Tc using a modified electrolytic method. The exact labeling mechanism has not been determined. Experimental data suggest that the labeling process of /99m/Tc-fibrinogen is quite similar to that of /sup 99m/Tc-human serum albumin as reported earlier by Benjamin. Technetium-99m-fibrinogen is stable in human plasma or in 1 percent buffered human serum albumin. A binding efficiency of 76 percent has been achieved with approximately 25 percent clottable protein. The entire labeling procedure requires less than 1 hr of preparation time. This short labeling time in a closed system may allow development of a practical method for labeling autologous fibrinogen, thus eliminating the risk of hepatitis transmission. (U.S.)

  9. PLUTONIUM PURIFICATION PROCESS EMPLOYING THORIUM PYROPHOSPHATE CARRIER

    Science.gov (United States)

    King, E.L.

    1959-04-28

    The separation and purification of plutonium from the radioactive elements of lower atomic weight is described. The process of this invention comprises forming a 0.5 to 2 M aqueous acidffc solution containing plutonium fons in the tetravalent state and elements with which it is normally contaminated in neutron irradiated uranium, treating the solution with a double thorium compound and a soluble pyrophosphate compound (Na/sub 4/P/sub 2/O/sub 7/) whereby a carrier precipitate of thorium A method is presented of reducing neptunium and - trite is advantageous since it destroys any hydrazine f so that they can be removed from solutions in which they are contained is described. In the carrier precipitation process for the separation of plutonium from uranium and fission products including zirconium and columbium, the precipitated blsmuth phosphate carries some zirconium, columbium, and uranium impurities. According to the invention such impurities can be complexed and removed by dissolving the contaminated carrier precipitate in 10M nitric acid, followed by addition of fluosilicic acid to about 1M, diluting the solution to about 1M in nitric acid, and then adding phosphoric acid to re-precipitate bismuth phosphate carrying plutonium.

  10. Flame-Retardant and Thermal Degradation Mechanism of Caged Phosphate Charring Agent with Melamine Pyrophosphate for Polypropylene

    Directory of Open Access Journals (Sweden)

    Xuejun Lai

    2015-01-01

    Full Text Available An efficient caged phosphate charring agent named PEPA was synthesized and combined with melamine pyrophosphate (MPP to flame-retard polypropylene (PP. The effects of MPP/PEPA on the flame retardancy and thermal degradation of PP were investigated by limiting oxygen index (LOI, vertical burning test (UL-94, cone calorimetric test (CCT, and thermogravimetric analysis (TGA. It was found that PEPA showed an outstanding synergistic effect with MPP in flame retardant PP. When the content of PEPA was 13.3 wt% and MPP was 6.7 wt%, the LOI value of the flame retardant PP was 33.0% and the UL-94 test was classed as a V-0 rating. Meanwhile, the peak heat release rate (PHRR, average heat release rate (AV-HRR, and average mass loss rate (AV-MLR of the mixture were significantly reduced. The flame-retardant and thermal degradation mechanism of MPP/PEPA was investigated by TGA, Fourier transform infrared spectroscopy (FTIR, TG-FTIR, and scanning electron microscopy-energy dispersive X-ray spectrometry (SEM-EDXS. It revealed that MPP/PEPA could generate the triazine oligomer and phosphorus-containing compound radicals which changed the thermal degradation behavior of PP. Meanwhile, a compact and thermostable intumescent char was formed and covered on the matrix surface to prevent PP from degrading and burning.

  11. Removal of technetium from alkaline nuclear-waste media by a solvent-extraction process using crown ethers

    International Nuclear Information System (INIS)

    Bonnesen, P.V.; Presley, D.J.; Haverlock, T.J.; Moyer, B.A.

    1995-01-01

    Crown ethers dissolved in suitably modified aliphatic kerosene diluents can be employed to extract technetium as pertechnetate anion (TcO 4 - ) with good extraction ratios from realistic simulants of radioactive alkaline nitrate waste. The modifiers utilized are non-halogenated and non-volatile, and the technetium can be removed from the solvent by stripping using water. The crown ethers bis-4,4'(5')[(tert-butyl)cyclohexano]-18-crown-6 (di-t-BuCH18C6) and dicyclohexano-18-crown-6 (DCH18C6) provide stronger TcO 4 - extraction than dicyclohexano-21-crown-7 and 4-tert-butylcyclohexano 15-crown-5. Whereas DCH18C6 provides somewhat higher TcO 4 - extraction ratios than the more lipophilic di-t-BuCH18C6 derivative, the latter was selected for further study owing to its lower distribution to the aqueous phase. Particularly good extraction and stripping results were obtained with di-t-BuCH 18C6 at 0.02 M in a 2:1 vol/vol blend of tributyl phosphate and Isopar reg-sign M. Using this solvent, 98.9% of the technetium contained (at 6 x 10 -5 M) in a Double-Shell Slurry Feed (DSSF) Hanford tank waste simulant was removed following two cross-current extraction contacts. Two cross-current stripping contacts with deionized water afforded removal of 99.1% of the technetium from the organic solvent

  12. Mew organometallic complexes of technetium in different oxidation states

    International Nuclear Information System (INIS)

    Joachim, J.E.

    1993-09-01

    New organometallic compounds of Tc(I), Tc(III) and Tc(VII) were synthesized and their properties examined. These compounds were correlated with their homologous compounds of manganese and rhenium, which were also synthesized by the same route. The molecular and crystal structures of most technetium complexes and of the homologous complexes of manganese and rhenium were determined by single crystal X-ray diffraction. (orig.) [de

  13. Removal of Technetium, Carbon Tetrachloride, and Metals from DOE Properties - Final Report

    International Nuclear Information System (INIS)

    Mallouk, Thomas E.; Ponder, S.M.

    2000-01-01

    This research is a three year project involving close collaboration between chemists at Pennsylvania State University and materials scientists at Pacific Northwest National Laboratory (PNNL). The goal of the project is the development and characterization of supported reducing agents, and solid waste forms derived from them, which will be effective in remediation of aqueous wastes. The work follows the recent discovery that zero-valent metals, such as iron, are effective decontaminants for waste streams containing chlorinated hydrocarbons. Preliminary data, obtained at Penn State and elsewhere, have shown that the same strategy will be effective in reducing soluble compounds containing toxic metals (technetium, lead, mercury, and chromium) to insoluble forms. The Penn State group has prepared a new class of powerful reducing agents, called Ferragels, which consist of finely divided zero-valent metals on high surface area supports. Because the rate of the surface oxidation-reduction reaction depends on available surface area, Ferragels are more effective in every case tested to date than unsupported metals. The project will further develop and investigate the application of these composite materials to problems relevant to the DOE-EM mission, namely the detoxification of waste streams containing technetium, carbon tetrachloride, and toxic metal ions. The Penn State group will work closely with the PNNL group to prepare materials that are compatible with the highly corrosive liquid fraction of Hanford site tank waste, to conduct tests with waste simulants containing technetium, and to formulate and characterize vitrified waste forms derived from these materials

  14. Multi-organ technetium complexes production and use thereof

    International Nuclear Information System (INIS)

    Koehler, G.A.; Pestel, G.M.

    1976-01-01

    Chemical complexes, useful as radiopharmaceuticals, are formed by reacting technetium-99m with substituted or unsubstituted alkyl monophosphonic acids and certain ester derivatives thereof. The complexes are formed by reducing pertechnetate ion chemically or electrolytically in the presence of the phosphonic acid. By chemical modification of the phosphonic acid complexing agent, it is possible to ''tailor'' complexes for kidney, liver or bone imaging. The complexes are normally used in a physiologically acceptable aqueous medium. 20 Claims, No Drawings

  15. The impact of technetium-99m-radiopharmaceuticals' design on their biological behavior

    International Nuclear Information System (INIS)

    Jankovic, D.Lj.; Djokic, D.Dj. . E-mail address of corresponding author: drinaj@vin.bg.ac.yu; Jankovic, D.)

    2005-01-01

    The coordination has a great and not always predictable impact on the in-vivo behaviour of the small molecule into which the technetium-bearing chelate units is integrated. The different valence state of technetium in the complexes with some ligands changes the properties of these complexes, such as physico-chemical parameters and biological behaviour. The change of their biological behaviour has a great impact on quality of imaging study and on radiation dose to the patient. The results of the labelling of DPD and EHIDA with 99mTc(I) and their biological behaviour, in comparison with the same one for 99mTc(III)-DPD and 99mTc(III)-EHIDA complexes, confirmed that different oxidation state of 99mTc make possible forming variety of complexes with quite a different and unexpected biological behaviour. (author)

  16. Site-specific transition metal occupation in multicomponent pyrophosphate for improved electrochemical and thermal properties in lithium battery cathodes: a combined experimental and theoretical study.

    Science.gov (United States)

    Shakoor, Rana A; Kim, Heejin; Cho, Woosuk; Lim, Soo Yeon; Song, Hannah; Lee, Jung Woo; Kang, Jeung Ku; Kim, Yong-Tae; Jung, Yousung; Choi, Jang Wook

    2012-07-18

    As an attempt to develop lithium ion batteries with excellent performance, which is desirable for a variety of applications including mobile electronics, electrical vehicles, and utility grids, the battery community has continuously pursued cathode materials that function at higher potentials with efficient kinetics for lithium insertion and extraction. By employing both experimental and theoretical tools, herein we report multicomponent pyrophosphate (Li(2)MP(2)O(7), M = Fe(1/3)Mn(1/3)Co(1/3)) cathode materials with novel and advantageous properties as compared to the single-component analogues and other multicomponent polyanions. Li(2)Fe(1/3)Mn(1/3)Co(1/3)P(2)O(7) is formed on the basis of a solid solution among the three individual transition-metal-based pyrophosphates. The unique crystal structure of pyrophosphate and the first principles calculations show that different transition metals have a tendency to preferentially occupy either octahedral or pyramidal sites, and this site-specific transition metal occupation leads to significant improvements in various battery properties: a single-phase mode for Li insertion/extraction, improved cell potentials for Fe(2+)/Fe(3+) (raised by 0.18 eV) and Co(2+)/Co(3+) (lowered by 0.26 eV), and increased activity for Mn(2+)/Mn(3+) with significantly reduced overpotential. We reveal that the favorable energy of transition metal mixing and the sequential redox reaction for each TM element with a sufficient redox gap is the underlying physical reason for the preferential single-phase mode of Li intercalation/deintercalation reaction in pyrophosphate, a general concept that can be applied to other multicomponent systems. Furthermore, an extremely small volume change of ~0.7% between the fully charged and discharged states and the significantly enhanced thermal stability are observed for the present material, the effects unseen in previous multicomponent battery materials.

  17. Electrical conductivity of titanium pyrophosphate between 100 and 400 °C: effect of sintering temperature and phosphorus content

    DEFF Research Database (Denmark)

    Lapina, Alberto; Chatzichristodoulou, Christodoulos; Hallinder, Jonathan

    2014-01-01

    The synthesis of titanium pyrophosphate is carried out, and the material is sintered at different temperatures between 370 and 970 °C. Yttrium is added during the synthesis to act as acceptor dopant, but it is mainly present in the material in secondary phases. The conductivity is studied systema...... at 300–390 °C. Slow loss of phosphorus by evaporation over time and changes in the distribution of the amorphous phase during testing are suggested as causes of conductivity degradation above 220 °C.......The synthesis of titanium pyrophosphate is carried out, and the material is sintered at different temperatures between 370 and 970 °C. Yttrium is added during the synthesis to act as acceptor dopant, but it is mainly present in the material in secondary phases. The conductivity is studied...... to an amorphous secondary phase at the grain boundaries, associated with the presence of excess phosphorus in the samples. A contribution to the conductivity by point defects in the bulk may explain the conductivity trend in dry air and the difference in conductivity between oxidizing and reducing atmospheres...

  18. Os trigonum syndrome: use of bone scan in the diagnosis

    International Nuclear Information System (INIS)

    Johnson, R.P.; Collier, B.D.; Carrera, G.F.

    1984-01-01

    The os trigonum is an accessory bone of the foot found in 7% of the normal adult population. It is located at the posterolateral projection of the talus, and can occasionally give rise to symptoms of acute and chronic unexplained ankle pain. We report three patients, one with acute fracture and two with chronic ankle symptoms. Technetium 99 methylene diphosphonate showed intense focal uptake at the posterior talus pointing to the os trigonum as the site of symptoms. It was excised in two patients with complete relief. The third went on to develop an asymptomatic nonunion. We recommend bone scanning as a procedure that is helpful in delineating obscure pain in the ankle that may be due to chronic irritative nonunion of the os trigonum

  19. Precipitation process for the removal of technetium values from nuclear waste solutions

    Science.gov (United States)

    Walker, D.D.; Ebra, M.A.

    1985-11-21

    High efficiency removal of techetium values from a nuclear waste stream is achieved by addition to the waste stream of a precipitant contributing tetraphenylphosphonium cation, such that a substantial portion of the technetium values are precipitated as an insoluble pertechnetate salt.

  20. Simulation of technetium extraction behavior in UO2 (NO3)2-TcO4--HNO3-H2O/TBP-kerosene system

    International Nuclear Information System (INIS)

    Zhang Chunlong; He Hui; Chen Yanxin; Tang Hongbin

    2012-01-01

    By comparing and analyzing lots of reported data of technetium with the computing results, a modification function P(c 0 (U), t) was introduced to the existing distribution coefficient model of technetium, and a new mathematical model for simulating technetium extraction behavior in the system of UO 2 (NO 3 ) 2 -TcO 4 -HNO 3 -H 2 O/TBP- kerosene was established, as well as a computer program. The reliability of the program was verified by 179 sets of distribution coefficient data, and the results were found to agree well with experimental data. By comparing the reported data of technetium with the computing results, an evaluation was made to test the performance of the revised model. It turned out that the calculation results of the new model were more reliable than that of the one reported previously. The revised model and program can be the foundation to simulating technetium extraction behavior in the system of UO 2 (NO 3 ) 2 - TcO 4 - -HNO 3 -H 2 O/TBP-kerosene with the temperature scope from 10 to 60℃, U concentration from 0 to 280 g/L, and nitric acid concentration from 0.1 to 5 mol/L. (authors)

  1. Synthesis, libelling and bio-distribution of cerebral radiopharmaceuticals with Technetium 99

    International Nuclear Information System (INIS)

    Malek Saied, Nadia

    2013-01-01

    The prevalence of brain pathologies especially neurodegenerative diseases still increasing due to longer life expectancy and the age pyramid evolution that shows an increase in the proportion of the old persons. So, we count currently more than 30 million persons affected by a neuro-degenerative disease. It is estimated that this number will reach 100 million at 2050. Generally, these diseases are not fatal, but the intellectual handicap and/or the progressive physical deterioration which causes some of them (Alzheimer, Parkinson), may lead to the death. Despite the screening efforts, it remains difficult to establish an early and differential diagnosis. It is proposed that research provides new solutions for diagnostic to reduce the risk of mortality associated with these diseases and improve patient comfort. The first part of this presentation is dedicated to some definitions of the radiopharmaceuticals, the chemistry of technetium and rhenium and the strategies of labeling with Technetium. We propose first to give an overview concerning the target vectors and criteria for crossing of the hemato-encephalic barrier. In the second part we will present our results concerning the synthesis and the physico-chemical characterization of some ferrocenic ligands, radio-complex of the technetium-99 and their "rhenisted" analogues. We will expose some bio-distributions as well as the biochemical studies of certain cytectrenic molecules which showed a very interesting affinity for 5HT1A serotonergic receptors such as Tc-MP associated to the molecule of piperazine (2 - methoxyphenyl) as a vector of choice. This molecule allows an exceptional kinetic of extraction around (2.47 pou cent DI / g) in 5min pi. (Author)

  2. Molecular Engineering of Technetium and Rhenium Based Radiopharmaceuticals

    International Nuclear Information System (INIS)

    Zubieta, J.

    2003-01-01

    The research was based on the observation that despite the extraordinarily rich coordination chemistry of technetium and rhenium and several notable successes in reagent design, the extensive investigations by numerous research groups on a variety of N 2 S 2 and N 3 S donor type ligands and on HYNIC have revealed that the chemistries of these ligands with Tc and Re are rather complex, giving rise to considerable difficulties in the development of reliable procedures for the development of radiopharmaceutical reagents

  3. Preparation and characterisation of a sorbent suitable for technetium separation from environmental matrices

    International Nuclear Information System (INIS)

    Bartosova, A.; Rajec, P.; Reich, M.

    2003-01-01

    A sorbent based on Aliquat 336 anchored on hydrophobised silica gel support as an ion exchanger was prepared. Prepared sorbent was suitable for separation of technetium-99 from environmental matrices. The sorbent properties, sorption characteristic and distribution coefficient of 99 mTcO 4 - in various medium was studied. The chemical yield of Tc during separation process was determined using 99m Tc tracer and gamma measurement. Typical sorption recoveries of Tc for this sorbent from 0.1 M HNO 3 were more than 98 %. Typical desorption recoveries using 8 M HNO 3 were in the range 92 - 96 %. The commercial TEVA Spec resin from Eichrom Industries for comparison purpose was used as well. It was found that the prepared sorbent is suitable for separation of technetium from environmental matrices. (authors)

  4. Review of technetium chemistry research conducted at the University of Nevada Las Vegas

    International Nuclear Information System (INIS)

    Poineau, F.; Weck, P.F.; Forster, P.; Hartmann, T.; Mausolf, E.; Silva, G.W.C.; Czerwinski, K.R.; Rodriguez, E.E.; Sattelberger, A.P.; Jarvinen, G.D.; Cheetham, A.K.

    2009-01-01

    The chemistry of technetium is being explored at the University of Nevada Las Vegas. Our goal is to investigate both the applied and fundamental aspects of technetium chemistry, with a special emphasis on synthesis, separations, and materials science. The synthetic chemistry focuses on metal-metal multiple bonding, oxides and halides. Synthesis and characterizations of (n-Bu 4 N) 2 Tc 2 X 8 , Tc 2 (O 2 CCH 3 ) 4 X 2 (X = Cl, Br), TcO 2 , Bi 2 Tc 2 O 7 , Bi 3 TcO 8 , TcBr 3 and TcBr 4 have been performed. The applied chemistry is related to the behavior of Tc in the UREX process. Separation of U/Tc has been conducted using anion exchange resin and metallic Tc waste form synthesized and characterized. (author)

  5. Behavior of technetium in alkaline solution: Identification of non-pertechnetate species in high-level nuclear waste tanks at the Hanford reservation

    International Nuclear Information System (INIS)

    Lukens, Wayne W. Jr.; Shuh, David K.; Schroeder, Norman C.; Ashley, Kenneth R.

    2003-01-01

    Technetium is a long-lived (99Tc: 213,000 year half-life) fission product found in nuclear waste and is one of the important isotopes of environmental concern. The known chemistry of technetium suggests that it should be found as pertechnetate, TcO4-, in the extremely basic environment of the nuclear waste tanks at the Hanford site. However, other chemical forms of technetium are present in significant amounts in certain tanks, and these non-pertechnetate species complicate the treatment of the waste. The only spectroscopic characterization of these non-pertechnetate species is a series of X-ray absorption near edge structure (XANES) spectra of actual tank waste. To better understand the behavior of technetium under these conditions, we have investigated the reduction of pertechnetate in highly alkaline solution in the presence of compounds found in high-level waste. These results and the X-ray absorption fine structure (XAFS) spectra of these species are compared to the chemical behavior and XANES spectra of the actual non-pertechnetate species. The identity of the nonpertechnetate species is surprising

  6. Labelling of metaiodobenzylguanidine (MIBG) with Technetium-99m radionuclide

    International Nuclear Information System (INIS)

    Maula Eka Sriyani; Dini Natanegara; Aang Hanafiah Ws

    2015-01-01

    Various neuroendocrine tumors and their metastases are able to localized and staged by Metaiodobenzylguanidine (MIBG). MIBG is a molecule that has a chemical structure similarities with noradrenaline in the adrenal. The research on 131 I-MIBG has been successfully conducted in the tumor imaging. This research of preparing 99m Tc-MIBG that will be used as a diagnostic agent for adrenal tumors was carried out. MIBG labeling activities with technetium-99m radionuclide were carried out through labeling of MIBG with technetium-99m and radiochemical purity analysis. The labeling of MIBG was carried out using both direct and indirect methods with diethylene triamine pentaacetic acid (DTPA) as a co-ligand. Determination of 99m Tc-MIBG labeling efficiency was performed using paper chromatography with Whatman 3MM/dried acetone and Whatman 31ET/acetonitrile 50%. The results of labeling efficiency using the indirect method with DTPA as a co-ligand was obtained 93.44 ± 1.93%, which the concentration of MIBG was 2 mg/0.5 mL H 2 O, concentration of co-ligand was 37,5 μg of SnCl 2 .2H 2 O and DTPA of 1,125 mg at pH 6.5 for 15 minutes incubation in the room temperature ( 25 °C). (author)

  7. Role of eicosanoids and white blood cells in the beneficial effects of limited reperfusion after ischemia-reperfusion injury in skeletal muscle

    International Nuclear Information System (INIS)

    Anderson, R.J.; Cambria, R.A.; Dikdan, G.; Lysz, T.W.; Hobson, R.W. II

    1990-01-01

    Limiting the rate of reperfusion blood flow has been shown to be beneficial locally in models of ischemia-reperfusion injury. We investigated the effects of this on eicosanoids (thromboxane B2, 6-keto-PGF1 alpha, and leukotriene B4), white blood cell activation, and skeletal muscle injury as quantitated by triphenyltetrazolium chloride and technetium-99m pyrophosphate after ischemia-reperfusion injury in an isolated gracilis muscle model in 16 anesthetized dogs. One gracilis muscle in each dog was subjected to 6 hours of ischemia followed by 1 hour of limited reperfusion and then by a second hour of normal reperfusion. The other muscle was subjected to 6 hours of ischemia followed by 2 hours of normal reperfusion. Six dogs each were used as normal reperfusion controls (NR) and limited reperfusion controls (LR), with 5 dogs being treated with a thromboxane synthetase inhibitor (LR/TSI) and another five with a leukotriene inhibitor (LR/LI). LR in all three groups (LR, LR/TSI, and LR/LI) showed a benefit in skeletal muscle injury as measured by triphenyltetrazolim chloride and technetium-99m pyrophosphate when compared with NR. However, there was no significant difference between the groups with LR regarding eicosanoid levels and white blood cell activation when compared with NR. These results demonstrate that LR produces benefits by mechanisms other than those dependent upon thromboxane A2, prostacyclin, or white blood cell activation

  8. Parallel critical magnetic fields of superconducting hyperthin films of vanadium and technetium

    International Nuclear Information System (INIS)

    Teplov, A.A.; Mikheeva, M.N.

    1980-01-01

    The nature of limiting parallel magnetic fields Hsub(c parallel) destroying a superconducting state in films of vanadium and technetium is found out. A dependence of Hsub(c parallel) on the thickness of films up to d approximately 60 A is studied. The |dHsub(c parallel)sup(2)/dT|sub(Tsub(c)) derivative, which increases in the region of large d with the increase of 1/d and achieves the maximum va;ue at d approximately 100 A, was determined, using the experimental data. For the most thin films this derivative tends to drop (the value of the derivative changes from 16 up to 20.00 kOe 2 /k and for technetium and from 4 up to 2100 kOe 2 /k for vanadium). Such stop at |dHsub(c11)sup(2)/ dT|sub(Tsub(c)) growth during the decrease of d is not explained in the framework of the theory taking into account only orbital effects. An account of the additional paramagnetic effect (spin effects) leads to a good agreement of the experiment with the theory in the whole range of thicknesses for vanadium. For technetium films in the d range <=110 A the value of Hsub(c parallel) exceeds several times Hsub(c parallel) calculated with provision of spin effects. For d approximately 80 A and d approximately 55 A this increase achieves the triple value. This effect is explained qualitatively by the spin-orbital scattering appearing with the increase of the atomic number

  9. Precipitation of PEG/Carboxyl-Modified Gold Nanoparticles with Magnesium Pyrophosphate: A New Platform for Real-Time Monitoring of Loop-Mediated Isothermal Amplification.

    Science.gov (United States)

    Qin, Ailin; Fu, Lok Tin; Wong, Jacky K F; Chau, Li Yin; Yip, Shea Ping; Lee, Thomas M H

    2017-03-29

    Gold nanoparticles have proven to be promising for decentralized nucleic acid testing by virtue of their simple visual readout and absorbance-based quantification. A major challenge toward their practical application is to achieve ultrasensitive detection without compromising simplicity. The conventional strategy of thermocycling amplification is unfavorable (because of both instrumentation and preparation of thermostable oligonucleotide-modified gold nanoparticle probes). Herein, on the basis of a previously unreported co-precipitation phenomenon between thiolated poly(ethylene glycol)/11-mercaptoundecanoic acid co-modified gold nanoparticles and magnesium pyrophosphate crystals (an isothermal DNA amplification reaction byproduct), a new ultrasensitive and simple DNA assay platform is developed. The binding mechanism underlying the co-precipitation phenomenon is found to be caused by the complexation of carboxyl and pyrophosphate with free magnesium ions. Remarkably, poly(ethylene glycol) does not hinder the binding and effectively stabilizes gold nanoparticles against magnesium ion-induced aggregation (without pyrophosphate). In fact, a similar phenomenon is observed in other poly(ethylene glycol)- and carboxyl-containing nanomaterials. When the gold nanoparticle probe is incorporated into a loop-mediated isothermal amplification reaction, it remains as a red dispersion for a negative sample (in the absence of a target DNA sequence) but appears as a red precipitate for a positive sample (in the presence of a target). This results in a first-of-its-kind gold nanoparticle-based DNA assay platform with isothermal amplification and real-time monitoring capabilities.

  10. Clinical studies of alveolar-capillary permeability using technetium-99m DTPA aerosol

    International Nuclear Information System (INIS)

    Sundram, F.X.

    1995-01-01

    Soluble radioaerosols such as technetium-99m diethylene triamine pentacetate (DTPA) permit simple quantitative studies of alveolar-capillary permeability to be performed, since the submicronic aerosols are deposited mainly at the lung periphery and are cleared across the alveolar-capillary membrane. Regional alterations in permeability can also be noted using this radionuclide technique. We have measured the pulmonary epithelial permeability in normal subjects and the alteration in smokers, glue-sniffers, patients with inhalation burns, chronic obstructive pulmonary disease (COPD) and patients with lung metastases from thyroid cancer treated with radioiodine 131 I. In the normal volunteers, the time taken for 50% of inhaled 99m Tc DTPA to be cleared from the lungs (T1/2) was 66 minutes±1 sd of 12 mins. The smokers had a mean T1/2 of 20 mins±1 sd 4 min. In the hard-core glue-sniffing group, the majority were smokers who had stopped smoking and glue-sniffing for periods varying from 1 day to 42 days, and it was possible to note the changes in clearance times against period of abstinence. In the patients with inhalation burns, there was change in lung clearance arising from pulmonary epithelial damage; these patients showed increased rate of clearance (short T1/2) with mean T1/2 of 36 min±1 sd of 11 mins, while the retention images revealed regional lung damage in moderately severe inhalation burns. Twenty-four patients with COPD had inhalation scans done with Tc-99m tin colloid radioaerosol, and these images were compared with the perfusion lung scans done with 99m Tc macroaggregated albumin (MAA); in general the perfusion images matched the defects noted in the inhalation scans. The 99m Tc DTPA clearance rate in these patients was normal i.e. T1/2=78±14 mins. In the thyroid cancer patients with lung metastases, who had high doses of radioiodine treatment, the T1/2 values were normal or prolonged slightly, mean T1/2=76 min±23. (author)

  11. Evaluation of thyroid nodules with technetium-99m tetrofosmin dual-phase scintigraphy

    International Nuclear Information System (INIS)

    Kresnik, E.; Gallowitsch, H.J.; Mikosch, P.; Molnar, M.; Pipam, W.; Gomez, I.; Lind, P.

    1997-01-01

    Technetium-99m tetrofosmin, a lipophilic cationic complex molecule, was introduced for myocardial imaging. In some biodistribution studies it has also been reported to accumulate in the thyroid gland. Our objectives were to determine which thyroid nodules retain tetrofosmin and whether preoperative evaluation of malignancy is possible. Tetrofosmin scintigraphy was performed in 57 patients with a cold thyroid nodule on previously performed pertechnetate scintigraphy. All patients had undergone ultrasonography and sonographically guided fine-needle aspiration biopsy. The tetrofosmin scintigrams were obtained 5 min (early image) and 1 h (late image) after intravenous injection of 370 MBq. Only nodules that showed clear tracer retention after 1 h in comparison with retention at 5 min were classified as TETRO positive. Nodules without late retention were classified as TETRO negative. All patients underwent surgery and the histological results were compared with the results of tetrofosmin scintigraphy. Ten out of 11 patients with thyroid carcinoma (two pT1, three pT2, five pT4) were TETRO negative. One patient with papillary carcinoma (pT2) was TETRO positive. The mean nodular to thyroid tissue (N/T) ratio for the late scan was 1.0±0.20. There were 21 patients with thyroid adenomas (seven follicular, seven microfollicular and seven oxyphilic); 15 of these patients were TETRO positive and six TETRO negative. The mean N/T ratio for the late images was 1.34±0.41. All patients with degenerative goitre (24 cases) and the one patient with Hashimoto's disease were TETRO negative after 1 h and the N/T ratio was 0.92±0.12 on the late scan. Our results indicate that 99m Tc-tetrofosmin scanning is of little value preoperatively in distinguishing thyroid carcinoma from other thyroid nodules. Tetrofosmin tends to demonstrate thyroid adenomas but does not have a routine role in the assessment of thyroid nodules. (orig.). With 2 figs., 4 tabs

  12. Diagnostic pharmaco-scintigraphy with hepatic intra-arterial technetium-99m macroaggregated albumin in the determination of tumour to non-tumour uptake ratio in hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Lau, W.Y.; Leung, T.W.T.; Chan, M.; Leung, N.W.Y.; Metreweli, C.; Li, A.K.C.

    1994-01-01

    Between October 1990 and March 1993, 124 patients with hepatocellular carcinoma (HCC) underwent diagnostic pharmaco-scintigraphy with hepatic intraarterial technetium-99m macroaggregated albumin (TcMAA) to determine the tumorous to non-tumorous liver tissue uptake ratio (T/N ratio). There were 110 males and 14 females. Ages ranged from 16 to 73 with a median of 55 years. The range of T/N ratio was 0.7 to 19.3 with a median of 3.8. 12 patients with inoperable HCC were subsequently selected by predetermined criteria to undergo treatment with hepatic intraarterial yttrium-90 microspheres and the T/N ratios in these patients were validated by beta probe dosimetry and liquid scintillation count of multiple liver biopsies. The T/N ratio determined by preoperative diagnostic TcMAA scan corrected well with intraoperative beta probe dosimetry, with coefficient of correlation r = 0.82. Preoperative TcMAA scan also correlated well with liquid scintillation count of biopsy specimens. (author)

  13. Diagnostic Value of Technetium-99m-Dimercaptosuccinic Acid Scintigraphy in Prediction of Vesicoureteral Reflux in Children with First-time Febrile Urinary Tract Infection

    Directory of Open Access Journals (Sweden)

    Fatemeh Ataei

    2017-11-01

    Full Text Available Background: Imaging modalities such as voiding cystourethrography (VCUG, direct radionuclide cystography (DRNC, and renal cortical scintigraphy (RCS with technetium-99m dimercaptosuccinic acid (Tc-99mDMSA, are helpful in detecting possible abnormalities of urinary tract such as vesicoureteral reflux (VUR. However, there are confounding data regarding the preference of these modalities. In the present study, we aimed to assess the role of Tc-99mDMSA scan in prediction of possible VUR and the subsequent need for VCUG or DRNC. Materials and Methods: Three hundred fifty seven children under 14 years old with first-time febrile urinary tract infection (UTI who were admitted between April 2004 and February 2017 were enrolled. Data regarding to VCUG or DRNC in order to evaluate the presence of possible VUR were recorded. Finally, accuracy of Tc-99mDMSA scans in prediction of VUR were assessed. Results: Analyses showed a sensitivity and specificity of 95.65% and 14.72%, respectively for Tc-99mDMSA scan in detection of VUR. Patients with mild renal involvement in Tc-99mDMSA scans had a 3.5-fold greater risk of having VUR than those with a normal scans (odds ratio=3.5; 95% confidence interval [CI]: 1.4-8.58; p=0.007. In addition, the risk of VUR is up to 7.0-fold greater in children with moderate renal involvement (odds ratio=7.0; 95% CI: 2.6-13.2; p

  14. Influence of synthesis conditions on physicochemical parameters and corrosion inhibiting activity of strontium pyrophosphates SrMIIP2O7 (MII = Mg and Zn).

    Czech Academy of Sciences Publication Activity Database

    Gorodylova, N.; Dohnalová, Ž.; Šulcová, P.; Bělina, P.; Vlček, Milan

    2016-01-01

    Roč. 93, 1 April 2016 (2016), s. 77-86 ISSN 0300-9440 Institutional support: RVO:61389013 Keywords : anticorrosive properties * paint coating * pyrophosphate Subject RIV: CA - Inorganic Chemistry Impact factor: 2.858, year: 2016

  15. Peculiarities of the introduction of technetium isotopes into protein molecules - of human serum albumin as an example

    International Nuclear Information System (INIS)

    Stanko, V.I.; Ovsyannikov, N.N.; Zuykova, N.P.; Gouskov, A.F.; Kovalchouk, N.D.

    1978-07-01

    Pecularities of the introduction of the radioisotope technetium 99m into the molecules of human serum albumin have been investigated. Tin not only participates in the Tc(V11) reduction process, but is incorporated into the originating Tc albumin complex. It is shown that no more than four technetium atoms enter into bond with an albumin molecule. The authors express their opinion that in order to produce high-quality protein preparations, the albumin has to be modified through a polyfunctional complexing agent which forms an entirely saturated coordination complex with Tc(IV)

  16. Pecularities of the introduction of technetium isotopes into protein molecules using human serum albumin as an example

    International Nuclear Information System (INIS)

    Stanko, V.I.; Ovsyannikov, N.N.; Sujkova, N.P.; Gus'kov, A.F.; Koval'chuk, N.D.

    1978-01-01

    Pecularities of the introduction of the radioisotope technetium 99m into the molecules of human serum albumin have been investigated. Tin not only participates in the Tc(VII) reduction process, but is incorporated into the originating Tc albumin complex. It is shown that no more than four technetium atoms enter into bond with an albumin molecule. The authors express their opinion that in order to produce high-quality protein preparations, the albumin has to be modified through a polyfunctional complexing agent which forms an entirely saturated coordination complex with Tc(IV). (author)

  17. Enrichment and stripping voltametric behavior of technetium traces at a carbon paste electrode modified with TTA

    International Nuclear Information System (INIS)

    Dick, R.; Ruf, H.; Ache, H.J.

    1988-06-01

    The possibility of enrichment as well as the stripping voltammetric behavior of technetium traces at a carbon paste electrode modified with thenoyltrifluoroacetone (TTA) was studied. Accumulation of Tc(IV) on the electrode surface occurs without application of a deposition voltage due to complex formation with TTA, probably resulting Tc(TTA) 4 . During the following cathodic potential scan made with the differential pulse mode a characteristic current peak is obtained at -40 mV (vs. Ag/AgCl) which increases with Tc concentration and deposition time. However, Tc(IV) gives much more sensitive stripping current signals if a reductive deposition potential of -0.4 V is applied, presumably on account of the formation of Tc(TTA) 3 . In this case an anodic voltammetric scan was applied resulting a stripping peak at about +30 mV, the height of which is related to the concentration of Tc in solution as well as to the time of deposition. Calibration graphs revealed good reproducibility for analytical application. The lower detection limit for Tc(IV) achieved for 1 M sodium chloride solutions 4.6 x 10 -9 M. Tc(VII) is not enriched in the absence of reduction which takes place only from about -0.6 V on with the pH optimally set at 3.5. Therefore it is basically possible to discriminate Tc(IV) from Tc(VII). (orig.) [de

  18. Formamidine sulfinic acid as reducing agent in technetium-99m rhenium sulfide labelling

    Energy Technology Data Exchange (ETDEWEB)

    Neves, M; Patricio, L [Laboratorio Nacional de Engenharia e Technologia Industrial, Sacavem (Portugal). Dept. de Radioisotopes; Ferronha, H [Laboratorio Nacional de Investigacao Veterinaria, Lisboa (Portugal)

    1989-08-01

    Labelling kinetic studies, radiochemical characterization and particle size evaluation of {sup 99m}Tc rhenium sulfide colloid using formamidine sulfinic acid as reducing agent are described. Comparison with the same colloid which makes use of Sn-sodium pyrophosphate complex as reducing agent showed higher labelling yields, simplification of labelling procedure and a longer shelf life when formamidine sulfinic acid was used. (author) 15 refs.; 7 figs.

  19. Rationale and radiopharmaceuticals for myocardial imaging

    International Nuclear Information System (INIS)

    Poe, N.D.

    1976-01-01

    Static radionuclide imaging procedures are now available for evaluating regional myocardial perfusion and for detecting acute myocardial infarction. Thallium-201, a radiopharmaceutical which possesses many of the characteristics of potassium analogs, at present is receiving the greatest attention as a regional blood flow indicator. Ischemic lesions appear as areas of decreased tracer uptake. Unfortunately, this agent is expensive, is in limited supply and has a photopeak which is low for optimum imaging. Positive infarct images can be obtained with various technetium-99m chelates. Pyrophosphate appears to be the best of the technetium compounds studied to date although the mechanism of uptake of the chelates has not yet been fully elucidated. Therefore, quantitative measurements of infarct size are not justified. As perfusion imaging and infarct imaging provide useful, complementary data, a dual tracer approach to evaluating patients with suspected coronary artery disease and/or myocardial infarction is probably justifiable

  20. Forefront of PUREX system engineering. Chemistry and engineering of ruthenium, technetium and neptunium

    International Nuclear Information System (INIS)

    2004-07-01

    The paper reports the activity of the research committee organized by the Atomic Energy Society of Japan on 'Ruthenium and Technetium Chemistry in the PUREX System', with focusing on basic behaviors of ruthenium, technetium and neptunium in the PUREX process, the principles of plant design, and behaviors during the final waste treatment. The scope of the work includes the following major topics: (1) basic solution and solid-state chemistry; (2) basic solution and solid-state chemistry of minor actinides in particular, Np; (3) partitioning chemistry in the PUREX system and environmental behavior of the components; (4) processes of recovery, purification, and utilization of rare metal fission products; (5) field data on plant design, operation, decontamination, and decommissioning; (6) numerical process simulations and process control technologies; (7) compilation of a data base for process chemistry and plant engineering. (S. Ohno)