WorldWideScience

Sample records for tear gases

  1. Long Term Effects of Tear Gases on Respiratory System: Analysis of 93 Cases

    Directory of Open Access Journals (Sweden)

    Peri Arbak

    2014-01-01

    Full Text Available Aim. This study aimed to assess the long-term respiratory effects of tear gases among the subjects with history of frequent exposure. Materials and Methods. A questionnaire by NIOSH and pulmonary function tests was performed in 93 males exposed to the tear gases frequently and 55 nonexposed subjects. Results. The mean numbers of total exposure and last 2 years exposure were 8.4±6.4 times, 5.6±5.8 times, respectively. Tear gas exposed subjects were presented with a higher rate for cough and phlegm more than 3 months (24.7% versus 11.3%, P>0.05. Mean FEV1/FVC and % predicted MMFR in smoker exposed subjects are significantly lower than those in smoker controls (81.7% versus 84.1%, P=0.046 and 89.9% versus 109.6%, P=0.0004, resp.. % predicted MMFR in nonsmoker exposed subjects is significantly lower than that in nonsmoker controls (99.4% versus 113.1%, P=0.05. Odds ratios for chest tightness, exercise dyspnea, dyspnea on level ground, winter morning cough, phlegm, and daily phlegm were increased almost 2 to 2.5 folds among tear gas exposed subjects. Conclusion. The rates for respiratory complaints were high in the case of the exposure to the tear gases previously. Tears gas exposed subjects were found to be under the risk for chronic bronchitis.

  2. Transient receptor potential ankyrin 1 antagonists block the noxious effects of toxic industrial isocyanates and tear gases.

    Science.gov (United States)

    Bessac, Bret F; Sivula, Michael; von Hehn, Christian A; Caceres, Ana I; Escalera, Jasmine; Jordt, Sven-Eric

    2009-04-01

    The release of methyl isocyanate in Bhopal, India, caused the worst industrial accident in history. Exposures to industrial isocyanates induce lacrimation, pain, airway irritation, and edema. Similar responses are elicited by chemicals used as tear gases. Despite frequent exposures, the biological targets of isocyanates and tear gases in vivo have not been identified, precluding the development of effective countermeasures. We use Ca(2+) imaging and electrophysiology to show that the noxious effects of isocyanates and those of all major tear gas agents are caused by activation of Ca(2+) influx and membrane currents in mustard oil-sensitive sensory neurons. These responses are mediated by transient receptor potential ankyrin 1 (TRPA1), an ion channel serving as a detector for reactive chemicals. In mice, genetic ablation or pharmacological inhibition of TRPA1 dramatically reduces isocyanate- and tear gas-induced nocifensive behavior after both ocular and cutaneous exposures. We conclude that isocyanates and tear gas agents target the same neuronal receptor, TRPA1. Treatment with TRPA1 antagonists may prevent and alleviate chemical irritation of the eyes, skin, and airways and reduce the adverse health effects of exposures to a wide range of toxic noxious chemicals.

  3. Meniscus Tears (For Teens)

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español Meniscus Tears KidsHealth / For Teens / Meniscus Tears What's in this ... surgery to fix it. What Is a Meniscus Tear? Your knee is made up of three bones: ...

  4. 49 CFR 173.340 - Tear gas devices.

    Science.gov (United States)

    2010-10-01

    ... SHIPMENTS AND PACKAGINGS Gases; Preparation and Packaging § 173.340 Tear gas devices. (a) Packagings for...) Tear gas devices may not be assembled with, or packed in the same packaging with, mechanically- or manually-operated firing, igniting, bursting, or other functioning elements unless of a type and design...

  5. Interaction of tearing modes

    International Nuclear Information System (INIS)

    Satya, Y.; Schmidt, G.

    1979-01-01

    A fully developed tearing mode modifies the magnetic field profile. The effect of this profile modification on the linear growth rate of a different tearing mode in a slab and cylindrical geometry is investigated

  6. Blocked Tear Duct

    Science.gov (United States)

    ... of the nose (lacrimal sac). From there tears travel down a duct (the nasolacrimal duct) draining into your nose. Once in the nose, tears are reabsorbed. A blockage can occur at any point in the tear drainage system, from the puncta ...

  7. Streaming tearing mode

    Science.gov (United States)

    Shigeta, M.; Sato, T.; Dasgupta, B.

    1985-01-01

    The magnetohydrodynamic stability of streaming tearing mode is investigated numerically. A bulk plasma flow parallel to the antiparallel magnetic field lines and localized in the neutral sheet excites a streaming tearing mode more strongly than the usual tearing mode, particularly for the wavelength of the order of the neutral sheet width (or smaller), which is stable for the usual tearing mode. Interestingly, examination of the eigenfunctions of the velocity perturbation and the magnetic field perturbation indicates that the streaming tearing mode carries more energy in terms of the kinetic energy rather than the magnetic energy. This suggests that the streaming tearing mode instability can be a more feasible mechanism of plasma acceleration than the usual tearing mode instability.

  8. Greenhouse Gases

    Science.gov (United States)

    ... Production of Hydrogen Use of Hydrogen Greenhouse Gases Basics | | Did you know? Without naturally occurring greenhouse gases, the earth would be too cold to support life as we know it. Without the greenhouse effect, ...

  9. Assessment of lamellar tearing

    International Nuclear Information System (INIS)

    McEnerney, J.W.

    1978-03-01

    Information on lamellar tearing is summarized and related to proposed ASME Code requirements. Lamellar tearing is characterized as a complex phenomenon related to poor short transverse ductility and through-thickness strain. The material, welding, and design variables that affect lamellar tearing are shown to be complex and interrelated. The commonly reported tests for assessing material susceptibility are described, with the controversy over their validity being carefully detailed. Although the use of a nondestructive test such as ultrasonic examination is most desirable, a widely applicable test method does not appear to be available. Of the destructive tests, the short transverse tensile reduction-of-area currently offers the most applicable means of assessing material susceptibility. However, because of the importance of matrix toughness, the short transverse Charpy V-notch test should be considered for use as an additional test if acceptance limits are developed. The ultrasonic detection of lamellar tears is susceptible to interpretation errors, which can make it overly conservative and lead to unnecessary repairs. The repair of tears is described as costly, difficult, and sometimes ineffective. Current design requirements appear to preclude any failures during static and fatigue service loads. However, without improvement of short transverse ductility, certain dynamic service loads could cause lamellar tearing failures. Two alternate design paths are recommended to prevent tearing during fabrication or service loading. The current and proposed ASME requirements dealing with lamellar tearing are reviewed and recommendations are made

  10. Iatrogenic tracheal tear.

    LENUS (Irish Health Repository)

    Dias, A

    2010-10-01

    Large post intubation tracheal tears are usually detected intra-operatively due to unstable signs namely impaired ventilation and mediastinal emphysema and often require surgical management. Smaller tracheal tears are often missed during anaesthesia and recognized during the postoperative period. Conservative management should be considered in these latter cases.

  11. Tearing instabilities in turbulence

    International Nuclear Information System (INIS)

    Ishizawa, A.; Nakajima, N.

    2009-01-01

    Full text: Effects of micro-turbulence on tearing instabilities are investigated by numerically solving a reduced set of two-fluid equations. Micro-turbulence excites both large-scale and small-scale Fourier modes through energy transfer due to nonlinear mode coupling. The energy transfer to large scale mode does not directly excite tearing instability but it gives an initiation of tearing instability. When tearing instability starts to grow, the excited small scale mode plays an important role. The mixing of magnetic flux by micro-turbulence is the dominant factor of non-ideal MHD effect at the resonant surface and it gives rise to magnetic reconnection which causes tearing instability. Tearing instabilities were investigated against static equilibrium or flowing equilibrium so far. On the other hand, the recent progress of computer power allows us to investigate interactions between turbulence and coherent modes such as tearing instabilities in magnetically confined plasmas by means of direct numerical simulations. In order to investigate effects of turbulence on tearing instabilities we consider a situation that tearing mode is destabilized in a quasi-equilibrium including micro-turbulence. We choose an initial equilibrium that is unstable against kinetic ballooning modes and tearing instabilities. Tearing instabilities are current driven modes and thus they are unstable for large scale Fourier modes. On the other hand kinetic ballooning modes are unstable for poloidal Fourier modes that are characterized by ion Larmor radius. The energy of kinetic ballooning modes spreads over wave number space through nonlinear Fourier mode coupling. We present that micro-turbulence affects tearing instabilities in two different ways by three-dimensional numerical simulation of a reduced set of two-fluid equations. One is caused by energy transfer to large scale modes, the other is caused by energy transfer to small scale modes. The former is the excitation of initial

  12. Idiopathic Bilateral Bloody Tearing

    Directory of Open Access Journals (Sweden)

    Emrullah Beyazyıldız

    2015-01-01

    Full Text Available Bloody tear is a rare and distinct clinic phenomenon. We report a case presenting with the complaint of recurrent episodes of bilateral bloody tearing. A 16-year-old girl presented to our clinic with complaint of bloody tearing in both eyes for 3 months. Bloody tearing was not associated with her menses. A blood-stained discharge from the punctum was not observed during the compression of both nasolacrimal ducts. Nasolacrimal passage was not obstructed. Imaging studies such as dacryocystography and gradient-echo magnetic resonance imaging (MRI of nasolacrimal canal were normal. Intranasal endoscopic evaluation was normal. We collected samples from bloody tears two times and pathological examination was performed. Pathological analysis showed lots of squamous cells and no endometrial cells; dysplastic cells were found. Further evaluations for underlying causes were unremarkable. No abnormalities were found in ophthalmologic, radiologic, and pathologic investigations. This condition is likely a rare abnormality and the least recognized aetiology for the idiopathic phenomenon.

  13. Antimicrobial compounds in tears.

    Science.gov (United States)

    McDermott, Alison M

    2013-12-01

    The tear film coats the cornea and conjunctiva and serves several important functions. It provides lubrication, prevents drying of the ocular surface epithelia, helps provide a smooth surface for refracting light, supplies oxygen and is an important component of the innate defense system of the eye providing protection against a range of potential pathogens. This review describes both classic antimicrobial compounds found in tears such as lysozyme and some more recently identified such as members of the cationic antimicrobial peptide family and surfactant protein-D as well as potential new candidate molecules that may contribute to antimicrobial protection. As is readily evident from the literature review herein, tears, like all mucosal fluids, contain a plethora of molecules with known antimicrobial effects. That all of these are active in vivo is debatable as many are present in low concentrations, may be influenced by other tear components such as the ionic environment, and antimicrobial action may be only one of several activities ascribed to the molecule. However, there are many studies showing synergistic/additive interactions between several of the tear antimicrobials and it is highly likely that cooperativity between molecules is the primary way tears are able to afford significant antimicrobial protection to the ocular surface in vivo. In addition to effects on pathogen growth and survival some tear components prevent epithelial cell invasion and promote the epithelial expression of innate defense molecules. Given the protective role of tears a number of scenarios can be envisaged that may affect the amount and/or activity of tear antimicrobials and hence compromise tear immunity. Two such situations, dry eye disease and contact lens wear, are discussed here. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Electronegative gases

    International Nuclear Information System (INIS)

    Christophorou, L.G.

    1981-01-01

    Recent knowledge on electronegative gases essential for the effective control of the number densities of free electrons in electrically stressed gases is highlighted. This knowledge aided the discovery of new gas dielectrics and the tailoring of gas dielectric mixtures. The role of electron attachment in the choice of unitary gas dielectrics or electronegative components in dielectric gas mixtures, and the role of electron scattering at low energies in the choice of buffer gases for such mixtures is outlined

  15. Greenhouse Gases

    Science.gov (United States)

    ... also produced by human activities. Some, such as industrial gases, are exclusively human made. What are the types ... Carbon dioxide (CO2) Methane (CH4) Nitrous oxide (N2O) Industrial gases: Hydrofluorocarbons (HFCs) Perfluorocarbons (PFCs) Sulfur hexafluoride (SF6 Nitrogen ...

  16. As tears go by : Baby tears trigger more brain activity than adult tears in nulliparous women

    NARCIS (Netherlands)

    Hendricx-Riem, M.M.E.; De Carli, P.; van IJzendoorn, M.H.; Vingerhoets, A.J.J.M.; Bakermans-Kranenburg, M.J.

    2017-01-01

    The current functional magnetic resonance imaging study examines brain activity during the perception of infant and adult tears. Infant tears evoke stronger responses in the visual cortex than adult tears, indicating that infant tears are highly salient. In addition, our study shows that infant

  17. Hip Labral Tear

    Science.gov (United States)

    ... that joint in the future. Prevention Hip labral tears are often associated with sports participation. If your sport puts a lot of strain on your hips, condition the surrounding muscles with strength and flexibility exercises. Try to avoid ...

  18. Haemolacria (bloody tears)

    African Journals Online (AJOL)

    PROF. EZECHUKWU

    2014-08-06

    Aug 6, 2014 ... menstruation, drugs, hyperthyroidism, nasolacrimal tu- berculosis ... no bleeding from any other body orifice. However ... All age groups can be affected from infancy to ... the system and thus lead to bloody tears emerging from.

  19. Meniscotibial (coronary) ligament tears

    International Nuclear Information System (INIS)

    El-Khoury, G.Y.; Usta, H.Y.; Berger, R.A.

    1984-01-01

    Preservation of the meniscus whenever possible is essential in maintaining knee stability and preventing premature osteoarthritis. Peripheral meniscal tears are the most amenable to surgical repair. This study evaluates the peripheral attachments of the medial meniscus and focuses on a specific tear limited to the meniscotibial ligament (coronary ligament). The diagnosis is made arthrographically when the medial meniscus floats above the tibial plateau without separating completely from the capsule. The lateral meniscus is rarely involved in this type of injury. (orig.)

  20. The tear turnover and tear clearance tests - a review.

    Science.gov (United States)

    Garaszczuk, Izabela K; Montes Mico, Robert; Iskander, D Robert; Expósito, Alejandro Cerviño

    2018-03-01

    The aim is to provide a summary of methods available for the assessment of tear turnover and tear clearance rates. The review defines tear clearance and tear turnover and describes their implication for ocular surface health. Additionally, it describes main types of techniques for measuring tear turnover, including fluorescein tear clearance tests, techniques utilizing electromagnetic spectrum and tracer molecule and novel experimental techniques utilizing optical coherence tomography and fluorescein profilometry. Areas covered: Internet databases (PubMed, Science Direct, Google Scholar) and most frequently cited references were used as a principal resource of information on tear turnover rate and tear clearance rate, presenting methodologies and equipment, as well as their definition and implications for the anterior eye surface health and function. Keywords used for data-search were as follows: tear turnover, tear clearance, fluorescein clearance, scintigraphy, fluorophotometry, tear flow, drainage, tear meniscus dynamics, Krehbiel flow and lacrimal functional unit. Expert commentary: After decades, the topic of tear turnover assessment has been reintroduced. Recently, new techniques have been developed to propose less invasive, less time consuming and simpler methodologies for the assessment of tear dynamics that have the potential to be utilized in clinical practice.

  1. Human tears contain a chemosignal.

    Science.gov (United States)

    Gelstein, Shani; Yeshurun, Yaara; Rozenkrantz, Liron; Shushan, Sagit; Frumin, Idan; Roth, Yehudah; Sobel, Noam

    2011-01-14

    Emotional tearing is a poorly understood behavior that is considered uniquely human. In mice, tears serve as a chemosignal. We therefore hypothesized that human tears may similarly serve a chemosignaling function. We found that merely sniffing negative-emotion-related odorless tears obtained from women donors induced reductions in sexual appeal attributed by men to pictures of women's faces. Moreover, after sniffing such tears, men experienced reduced self-rated sexual arousal, reduced physiological measures of arousal, and reduced levels of testosterone. Finally, functional magnetic resonance imaging revealed that sniffing women's tears selectively reduced activity in brain substrates of sexual arousal in men.

  2. Tear secretion and tear stability of women on hormonal contraceptives

    Directory of Open Access Journals (Sweden)

    Faustina Kemdinum Idu

    2013-01-01

    Conclusions: Injectable hormonal contraceptives had no significant effects on tear secretion and tear stability of healthy women of childbearing age. Further studies may be required to determine the effects of hormonal contraceptives on tear volume and stability of women with dry eyes.

  3. Nonlinear drift tearing mode

    International Nuclear Information System (INIS)

    Zelenyj, L.M.; Kuznetsova, M.M.

    1989-01-01

    Nonlinear study of magnetic perturbation development under single-mode conditions in collision-free plasma in configurations with the magnetic field shear is investigated. Results are obtained with regard of transverse component of electrical field and its effect on ion dynamics within wide range of ion Larmor radius value and values of magnetic field shear. Increments of nonlinear drift tearing mode are obtained and it is shown that excitation drastic conditions of even linearly stable modes are possible. Mechanism of instability nonlinear stabilization is considered and the value of magnetic island at the saturation threshold is estimeted. Energy of nonlinear drift tearing mode is discussed

  4. Tears of Wine

    Science.gov (United States)

    Gugliotti, Marcos

    2004-01-01

    The unique occurrence of the upward motion of a thin film of wine, and its formation into drops inside the wall of a wine glass is explained. Evaporation of alcohol generates a surface tension gradient, moving the film of wine upwards on the internal sides of a wine glass, where it collects and forms into drops or tears.

  5. Irritant gases

    NARCIS (Netherlands)

    Meulenbelt, J

    Acute inhalation injury can result from the use of household cleaning agents (e.g. chlorine, ammonia), industrial or combustion gases (e.g. sulfur dioxide, nitrogen oxides) or bioterrorism. The severity of the injury is to a great extent determined by the circumstances of exposure. If exposure was

  6. Software Simulation of Hot Tearing

    DEFF Research Database (Denmark)

    Andersen, S.; Hansen, P.N.; Hattel, Jesper Henri

    1999-01-01

    The brittleness of a solidifying alloy in a temperature range near the solidus temperature has been recognised since the fifties as the mechanism responsible for hot tearing. Due to this brittlenes, the metal will crack under even small amounts of strain in that temperature range. We see these hot...... tears in castings close to hot centres, where the level of strain is often too high.Although the hot tearing mechanism is well understood, until now it has been difficult to do much to reduce the hot tearing tendency in a casting. In the seventies, good hot tearing criteria were developed by considering...... the solidification rate and the strain rate of the hot tear prone areas. But, until recently it was only possible to simulate the solidification rate, so that the criteria could not be used effectively.Today, with new software developments, it is possible to also simulate the strain rate in the hot tear prone areas...

  7. Industrial gases

    International Nuclear Information System (INIS)

    Hunter, D.; Jackson, D.; Coeyman, M.

    1993-01-01

    Industrial gas companies have fought hard to boost sales and hold margins in the tough economic climate, and investments are well down from their 1989-'91 peak. But 'our industry is still very strong long term' says Alain Joly, CEO of industry leader L'Air Liquide (AL). By 1994, if a European and Japanese recovery follows through on one in the U.S., 'we could see major [investment] commitments starting again,' he says. 'Noncryogenic production technology is lowering the cost of gas-making possible new applications, oxygen is getting plenty of attention in the environmental area, and hydrogen also fits into the environmental thrust,' says Bob Lovett, executive v.p./gases and equipment with Air Products ampersand Chemicals (AP). Through the 1990's, 'Industrial gases could grow even faster than in the past decade,' he says. Virtually a new generation of new gases applications should become reality by the mid-1990s, says John Campbell, of industry consultants J.R. Campbell ampersand Associates (Lexington, MA). Big new oxygen volumes will be required for powder coal injection in blast furnaces-boosting a steel mill's requirement as much as 40% and coal gasification/combined cycle (CGCC). Increased oil refinery hydroprocessing needs promise hydrogen requirements

  8. [Rotator cuff tear athropathy prevalence].

    Science.gov (United States)

    Guerra-Soriano, F; Encalada-Díaz, M I; Ruiz-Suárez, M; Valero-González, F S

    2017-01-01

    Glenohumeral arthritis secondary to massive rotator cuff tear presents with a superior displacement and femoralization of the humeral head with coracoacromial arch acetabularization. The purpose of this study was to establish prevalence of rotator cuff tear artropathy (CTA) at our institution. Four hundred electronic records were reviewed from which we identified 136 patients with rotator cuff tears. A second group was composed with patients with massive cuff tears that were analized and staged by the Seebauer cuff tear arthropathy classification. Thirty four patients with massive rotator cuff tears were identified, 8 male and 26 female (age 60.1 ± 10.26 years). Massive rotator cuff tear prevalence was 25%. CTA prevalence found in the rotator cuff group was 19 and 76% in the massive cuff tears group. Patients were staged according to the classification with 32% in stage 1a, 11% 1b, 32% 2a and 0% 2b. CTA prevalence in patients with rotator cuff tears and massive cuff tears is higher than the one reported in American population. We consider that a revision of the Seebauer classification to be appropriate to determine its reliability.

  9. Pele's tears and spheres

    Science.gov (United States)

    Porritt, L. A.; Quane, S.; Russell, K.

    2011-12-01

    Pele's tears are a well known curiosity commonly associated with low viscosity basaltic explosive eruptions. However, these pyroclasts are rarely studied in detail and there is no full explanation for their formation. These intriguing pyroclasts have smooth glassy surfaces, vesiculated interiors, and fluidal morphologies tending towards droplets and then spheres as they decrease in size to Pele's tears from the 1959 fire-fountaining eruption of Kilauea Iki involving size and density measurements. Using thin section and SEM analysis we also consider their internal and external morphologies, porosity and bubble size distributions, and surface textures. Finally we consider the mechanisms of magma fragmentation, timescales of relaxation, and cooling rates that are responsible for their formation.

  10. Noble Gases

    Science.gov (United States)

    Podosek, F. A.

    2003-12-01

    The noble gases are the group of elements - helium, neon, argon, krypton, xenon - in the rightmost column of the periodic table of the elements, those which have "filled" outermost shells of electrons (two for helium, eight for the others). This configuration of electrons results in a neutral atom that has relatively low electron affinity and relatively high ionization energy. In consequence, in most natural circumstances these elements do not form chemical compounds, whence they are called "noble." Similarly, much more so than other elements in most circumstances, they partition strongly into a gas phase (as monatomic gas), so that they are called the "noble gases" (also, "inert gases"). (It should be noted, of course, that there is a sixth noble gas, radon, but all isotopes of radon are radioactive, with maximum half-life a few days, so that radon occurs in nature only because of recent production in the U-Th decay chains. The factors that govern the distribution of radon isotopes are thus quite different from those for the five gases cited. There are interesting stories about radon, but they are very different from those about the first five noble gases, and are thus outside the scope of this chapter.)In the nuclear fires in which the elements are forged, the creation and destruction of a given nuclear species depends on its nuclear properties, not on whether it will have a filled outermost shell when things cool off and nuclei begin to gather electrons. The numerology of nuclear physics is different from that of chemistry, so that in the cosmos at large there is nothing systematically special about the abundances of the noble gases as compared to other elements. We live in a very nonrepresentative part of the cosmos, however. As is discussed elsewhere in this volume, the outstanding generalization about the geo-/cosmochemistry of the terrestrial planets is that at some point thermodynamic conditions dictated phase separation of solids from gases, and that the

  11. Fuel gases

    International Nuclear Information System (INIS)

    Anon.

    1996-01-01

    This paper gives a brief presentation of the context, perspectives of production, specificities, and the conditions required for the development of NGV (Natural Gas for Vehicle) and LPG-f (Liquefied Petroleum Gas fuel) alternative fuels. After an historical presentation of 80 years of LPG evolution in vehicle fuels, a first part describes the economical and environmental advantages of gaseous alternative fuels (cleaner combustion, longer engines life, reduced noise pollution, greater natural gas reserves, lower political-economical petroleum dependence..). The second part gives a comparative cost and environmental evaluation between the available alternative fuels: bio-fuels, electric power and fuel gases, taking into account the processes and constraints involved in the production of these fuels. (J.S.)

  12. Tear dynamics in healthy and dry eyes.

    Science.gov (United States)

    Cerretani, Colin F; Radke, C J

    2014-06-01

    Dry-eye disease, an increasingly prevalent ocular-surface disorder, significantly alters tear physiology. Understanding the basic physics of tear dynamics in healthy and dry eyes benefits both diagnosis and treatment of dry eye. We present a physiological-based model to describe tear dynamics during blinking. Tears are compartmentalized over the ocular surface; the blink cycle is divided into three repeating phases. Conservation laws quantify the tear volume and tear osmolarity of each compartment during each blink phase. Lacrimal-supply and tear-evaporation rates are varied to reveal the dependence of tear dynamics on dry-eye conditions, specifically tear osmolarity, tear volume, tear-turnover rate (TTR), and osmotic water flow. Predicted periodic-steady tear-meniscus osmolarity is 309 and 321 mOsM in normal and dry eyes, respectively. Tear osmolarity, volume, and TTR all match available clinical measurements. Osmotic water flow through the cornea and conjunctiva contribute 10 and 50% to the total tear supply in healthy and dry-eye conditions, respectively. TTR in aqueous-deficient dry eye (ADDE) is only half that in evaporative dry eye (EDE). The compartmental periodic-steady tear-dynamics model accurately predicts tear behavior in normal and dry eyes. Inclusion of osmotic water flow is crucial to match measured tear osmolarity. Tear-dynamics predictions corroborate the use of TTR as a clinical discriminator between ADDE and EDE. The proposed model is readily extended to predict the dynamics of aqueous solutes such as drugs or fluorescent tags.

  13. Linear stability of tearing modes

    International Nuclear Information System (INIS)

    Cowley, S.C.; Kulsrud, R.M.; Hahm, T.S.

    1986-05-01

    This paper examines the stability of tearing modes in a sheared slab when the width of the tearing layer is much smaller than the ion Larmor radius. The ion response is nonlocal, and the quasineutrality retains its full integal form. An expansion procedure is introduced to solve the quasineutrality equation in powers of the width of the tearing layer over the ion Larmor radius. The expansion procedure is applied to the collisionless and semi-collisional tearing modes. The first order terms in the expansion we find to be strongly stabilizing. The physics of the mode and of the stabilization is discussed. Tearing modes are observed in experiments even though the slab theory predicts stability. It is proposed that these modes grow from an equilibrium with islands at the rational surfaces. If the equilibrium islands are wider than the ion Larmor radius, the mode is unstable when Δ' is positive

  14. MRI diagnosis of meniscal tears

    International Nuclear Information System (INIS)

    Kuga, Naoyuki; Oh, Toshihiro

    1996-01-01

    We studied the accuracy of magnetic resonance imaging (MRI) of the knee in fifty-six patients who were also examined arthroscopically. The accuracy, sensitivity, and specificity were 96%, 100%, and 95% for medial meniscal tears, and 91%, 67%, and 100% for lateral meniscal tears respectively. Two MRIs of the medial meniscus were false-positives. These MRI findings were both meniscocapsular separation of the medial meniscus, but the arthroscopic findings were normal. One case was an ACL injury and the other PCL and MCL injury. Hemorrhage and edema of the medial capsule caused by valgus stress at injury may look like a meniscal pseudo-tear on MRI. Five MRIs of the lateral meniscus were false-negatives. All menisci showed normal signal and shape on MRI but traumatic and stable tears of the lateral meniscus were identified arthroscopically. All were associated with ACL tears and lateral condylar bone bruise. The traumatic and stable tear of the meniscus tended to be overlooked on MRI because a meniscus without degeneration shows a normal signal. (author)

  15. Examination of rotator cuff re-tear

    International Nuclear Information System (INIS)

    Kitahara, Hiroyuki; Yabe, Yoshihiro; Norimatsu, Takahiro; Adachi, Shinji; Sera, Keisuke

    2010-01-01

    The six-month post-operative re-tear rate in 72 arthroscopic rotator cuff repair cases was 16.3% by MRI. The re-tear rate of massive tears was 50%. We investigated the details of the re-tears by MRI and arthroscopic findings. High re-tear rates were connected with cuff tear size and fatty degeneration of muscle belly. Cases with poor cuff quality in arthroscopically showed high re-tear rate. These results suggest that surgery operation should be performed as soon as possible after diagnosis of cuff tear to obtain good results. Cases with damage of long head of the biceps (LHB) are likely to develop impingement causes of re-tears. Some type of rehabilitation is required to avoid impingement in such cases. (author)

  16. Tearing modes in toroidal geometry

    International Nuclear Information System (INIS)

    Connor, J.W.; Cowley, S.C.; Hastie, R.J.; Hender, T.C.; Hood, A.; Martin, T.J.

    1988-01-01

    The separation of the cylindrical tearing mode stability problem into a resistive resonant layer calculation and an external marginal ideal magnetohydrodynamic (MHD) calculation (Δ' calculation) is generalized to axisymmetric toroidal geometry. The general structure of this separation is analyzed and the marginal ideal MHD information (the toroidal generalization of Δ') required to discuss stability is isolated. This can then, in principle, be combined with relevant resonant layer calculations to determine tearing mode growth rates in realistic situations. Two examples are given: the first is an analytic treatment of toroidally coupled (m = 1, n = 1) and (m = 2, n = 1) tearing modes in a large aspect ratio torus; the second, a numerical treatment of the toroidal coupling of three tearing modes through finite pressure effects in a large aspect ratio torus. In addition, the use of a coupling integral approach for determining the stability of coupled tearing modes is discussed. Finally, the possibility of using initial value resistive MHD codes in realistic toroidal geometry to determine the necessary information from the ideal MHD marginal solution is discussed

  17. A comparison of basal and eye-flush tears for the analysis of cat tear proteins.

    Science.gov (United States)

    Petznick, Andrea; Evans, Margaret D M; Madigan, Michele C; Markoulli, Maria; Garrett, Qian; Sweeney, Deborah F

    2011-02-01

    To identify a rapid and effective tear collection method providing sufficient tear volume and total protein content (TPC) for analysis of individual proteins in cats. Domestic adult short-haired cats (12-37 months; 2.7-6.6 kg) were used in the study. Basal tears without stimulation and eye-flush tears after instillation of saline (10 μl) were collected using microcapillary tubes from animal eyes either unwounded control or wounded with 9-mm central epithelial debridement giving four groups with n = 3. Tear comparisons were based on total time and rate for tear collection, TPC using micro bicinchoninic acid (BCA), tear immunoglobulin A (IgA), total matrix-metalloproteinase (MMP)-9 concentration using sandwich enzyme-linked immunosorbent assay (ELISA) and MMP-9 activity. Eye-flush tears were collected significantly faster than basal tears in wounded eyes with higher rates for tear collection in unwounded control and wounded eyes. TPC was significantly lower in eye-flush tears compared to basal tears. The relative proportion of tear IgA normalized to TPC (% IgA of TPC) was not significantly different between basal and eye-flush tears. In unwounded control eyes, MMP-9 was slightly higher in eye-flush than in basal tears; activity of MMP-9 in both tear types was similar. In wounded eyes, eye-flush tears showed highest MMP-9 levels and activity on Day 1, which subsequently decreased to Day 7. MMP-9 activity in basal tears from wounded eyes did not display changes in expression. Eye-flush tears can be collected rapidly providing sufficient tear volume and TPC. This study also indicates that eye-flush tears may be more suitable than basal tears for the analysis of MMPs following corneal wounding. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.

  18. Anterior cruciate ligament tear: comparison of MR features between complete and partial tear

    International Nuclear Information System (INIS)

    Song, Ki Young; Lee, Joo Hyuk; Park, Jin Hee; Lee, Yu Jin; Rho, Eun Jin; Kim, Young Hoon; Yi, Jeong Geun; Ahn, Joong Mo

    1997-01-01

    To determine the MRI features which distinguish complete and partial tear of the anterior cruciate ligament(ACL) and to thus improve MRI interpretation. In 80 patients, we analyzed MR findings of direct and indirect signs of ACL tear (complete tear, 61 cases, partial tear, 19 cases) confirmed by arthroscopy or surgery, and compared the relative incidence of each sign in cases of complete and partial tear. Direct and indirect signs were found in 61 (100%) and 60 cases (98.4%), respectively, in complete tears, but in 16 (84.2%) and 15 cases (78.9%), respectively, in partial tears. Poor visualization, discontinuity and hyperintensity were seen in all complete tears but in only nine cases (47.4%) of partial tear. A wavy or abnormal contour was seen in 53 cases (86.9%) of complete tear and 14 (73.7%) of partial tear. A wavy contour without other direct signs was seen in only five cases (26.3%) of partial tear. Three cases (15.8%) of partial tear showed normal MR finding. Indirect signs, i.e. abnormal ACL angle, abnormal ACL-Blumensaat line angle, abnormal posterior cruciate ligament (PCL) line, abnormal PCL angle, PCL buckling, anterior displacement of tibia, posterior displacement of lateral meniscus, bone bruise, Segond fracture, tear of collateral ligaments, PCL, and tear of meniscus were commoner in complete than in partial tears. Two cases of O'Donoghue's triad and two of popliteus injury were seen only in complete tears. Direct and indirect signs of ACL tear were more commonly noted in complete than in partial tears. The latter showed MR features varying from normal to almost complete tear. We suggest that a wavy contour without other direct signs is indicative of a partial tear, and that O'Donoghue's triad and popliteus muscle injury are indirect signs of a complete tear

  19. Duplex Tear Film Evaporation Analysis.

    Science.gov (United States)

    Stapf, M R; Braun, R J; King-Smith, P E

    2017-12-01

    Tear film thinning, hyperosmolarity, and breakup can cause irritation and damage to the human eye, and these form an area of active investigation for dry eye syndrome research. Recent research demonstrates that deficiencies in the lipid layer may cause locally increased evaporation, inducing conditions for breakup. In this paper, we explore the conditions for tear film breakup by considering a model for tear film dynamics with two mobile fluid layers, the aqueous and lipid layers. In addition, we include the effects of osmosis, evaporation as modified by the lipid, and the polar portion of the lipid layer. We solve the system numerically for reasonable parameter values and initial conditions and analyze how shifts in these cause changes to the system's dynamics.

  20. What emotional tears convey : Tearful individuals are seen as warmer, but also as less competent

    NARCIS (Netherlands)

    van de Ven, Niels; Meijs, Maartje; Vingerhoets, A.J.J.M.

    Earlier research found that the mere sight of tears promotes the willingness to provide support to the person shedding the tears. Other research, however, found that deliberate responses towards tearful persons could be more negative as well. We think this is because tears have ambivalent effects on

  1. Surface tearing modes in tokamaks

    International Nuclear Information System (INIS)

    Takizuka, Tomonori; Kurita, Gen-ichi; Azumi, Masafumi; Takeda, Tatsuoki

    1985-10-01

    Surface tearing modes in tokamaks are studied numerically and analytically. The eigenvalue problem is solved to obtain the growth rate and the mode structure. We investigate in detail dependences of the growth rate of the m/n = 2/1 resistive MHD modes on the safety factor at the plasma surface, current profile, wall position, and resistivity. The surface tearing mode moves the plasma surface even when the wall is close to the surface. The stability diagram for these modes is presented. (author)

  2. Acute Medial Plantar Fascia Tear.

    Science.gov (United States)

    Pascoe, Stephanie C; Mazzola, Timothy J

    2016-06-01

    A 32-year-old man who participated in competitive soccer came to physical therapy via direct access for a chief complaint of plantar foot pain. The clinical examination findings and mechanism of injury raised a concern for a plantar fascia tear, so the patient was referred to the physician and magnetic resonance imaging was obtained. The magnetic resonance image confirmed a high-grade, partial-thickness, proximal plantar fascia tear with localized edema at the location of the medial band. J Orthop Sports Phys Ther 2016;46(6):495. doi:10.2519/jospt.2016.0409.

  3. A Special Tear Pattern of Anterior Horn of the Lateral Meniscus: Macerated Tear.

    Science.gov (United States)

    Zheng, Jiapeng; Zhai, Wenliang; Li, Qiang; Jia, Qianxin; Lin, Dasheng

    2017-01-01

    We describe a special, interesting phenomenon found in the anterior horn of the lateral meniscus (AHLM): most tear patterns in the AHLM are distinctive, with loose fibers in injured region and circumferential fiber bundles were separated. We name it as macerated tear. The goal of this study was to bring forward a new type of meniscal tear in the AHLM and investigate its clinical value. AHLM tears underwent arthroscopic surgery from January 2012 to December 2014 were included. Data regarding the integrity of AHLM were prospectively recorded in a data registry. Tear morphology and treatment received were subsequently extracted by 2 independent reviewers from operative notes and arthroscopic surgical photos. A total of 60 AHLM tears in 60 patients (mean age 27.1 years) were grouped into horizontal tears (n = 15, 25%), vertical tears (n = 14, 23%), complex tears (n = 6, 10%), and macerated tears (n = 25, 42%). There were 6 patients with AHLM cysts in macerated tear group and one patient in vertical tear group. 60 patients were performed arthroscopic meniscus repairs and were followed-up with averaged 18.7 months. Each group had significant postoperative improvement in Lysholm and IKDC scores (p 0.05). This study demonstrated that the macerated tear is common in the tear pattern of AHLM. However, feasibility of the treatment of this type of meniscal tear, especially the meniscus repairs still requires further study.

  4. Kinetic theory of tearing instabilities

    International Nuclear Information System (INIS)

    Drake, J.F.; Lee, Y.C.

    1977-01-01

    The transition of the tearing instability from the collisional to the collisionless regime is investigated kinetically using a Fokker--Planck collision operator to represent electron-ion collisions. As a function of the collisionality of the plasma, the tearing instability falls into three regions, which are referred to as collisionless, semi-collisional, and collisional. The width Δ of the singular layer around kxB 0 =0 is limited by electron thermal motion along B 0 in the collisional and semi-collisional regimes and is typically smaller than rho/sub i/, the ion Larmor radius. Previously accepted theories, which are based on the assumption Δvery-much-greater-thanrho/sub i/, are found to be valid only in the collisional regime. The effects of density and temperature gradients on the instabilities are also studied. The tearing instability is only driven by the temperature gradient in the collisional and semi-collisional regimes. Numerical calculations indicate that the semi-collisional tearing instability is particularly relevant to present day high temperature tokamak discharges

  5. Bifurcation of steady tearing states

    International Nuclear Information System (INIS)

    Saramito, B.; Maschke, E.K.

    1985-10-01

    We apply the bifurcation theory for compact operators to the problem of the nonlinear solutions of the 3-dimensional incompressible visco-resistive MHD equations. For the plane plasma slab model we compute branches of nonlinear tearing modes, which are stationary for the range of parameters investigated up to now

  6. Plate Tearing by a Cone

    DEFF Research Database (Denmark)

    Simonsen, Bo Cerup

    1997-01-01

    The present paper is concerned with steady-state plate tearing by a cone. This is a scenario where a cone is forced through a ductile metal plate with a constant lateral tip penetration in a motion in the plane of the plate. The considered process could be an idealisaton of the damage, which...... as for the out-of-plane reaction force....

  7. Energy balance in tearing modes

    International Nuclear Information System (INIS)

    Wesson, J.A.

    1993-01-01

    The energy balance in tearing modes is described in terms of exact separate energy balance equations. Each of these equations describes identified physical processes, and their sum gives the conservation of total energy. One of the energy balance equations corresponds to Furth's description. (Author)

  8. Classification and localization of acetabular labral tears

    International Nuclear Information System (INIS)

    Blankenbaker, D.G.; De Smet, A.A.; Keene, J.S.; Fine, J.P.

    2007-01-01

    The purpose of this study was to compare the findings on hip MR arthrography (MRA) with the published MRA and arthroscopic classifications of hip labral tears and to evaluate a clock-face method for localizing hip labral tears. We retrospectively reviewed 65 hip MRA studies with correlative hip arthroscopies. Each labrum was evaluated on MRA using the classification system of Czerny and an MRA modification of the Lage arthroscopic classification. In addition, each tear was localized on MRA by using a clock-face description where 6 o'clock was the transverse ligament and 3 o'clock was anterior. These MRA findings were then correlated with the arthroscopic findings using the clock-face method of localization and the Lage arthroscopic classification of labral tears. At MRA, there were 42 Czerny grade 2 and 23 grade 3 labral tears and 22 MRA Lage type 1, 11 type 2, 22 type 3 and 10 type 4 tears. At arthroscopy, there were 10 Lage type 1 flap tears, 20 Lage type 2 fibrillated tears, 18 Lage type 3 longitudinal peripheral tears and 17 Lage type 4 unstable tears. The Czerny MRA classification and the modified MRA Lage classification had borderline correlation with the arthroscopic Lage classification. Localization of the tears using a clock-face description was within 1 o'clock of the arthroscopic localization of the tears in 85% of the patients. The Lage classification, which is the only published arthroscopic classification system for hip labral tears, does not correlate well with the Czerny MRA or an MRA modification of the Lage classification. Using a clock-face description to localize tears provides a way to accurately localize a labral tear and define its extent. (orig.)

  9. Ultrasound determination of rotator cuff tear repairability

    Science.gov (United States)

    Tse, Andrew K; Lam, Patrick H; Walton, Judie R; Hackett, Lisa

    2015-01-01

    Background Rotator cuff repair aims to reattach the torn tendon to the greater tuberosity footprint with suture anchors. The present study aimed to assess the diagnostic accuracy of ultrasound in predicting rotator cuff tear repairability and to assess which sonographic and pre-operative features are strongest in predicting repairability. Methods The study was a retrospective analysis of measurements made prospectively in a cohort of 373 patients who had ultrasounds of their shoulder and underwent rotator cuff repair. Measurements of rotator cuff tear size and muscle atrophy were made pre-operatively by ultrasound to enable prediction of rotator cuff repairability. Tears were classified following ultrasound as repairable or irreparable, and were correlated with intra-operative repairability. Results Ultrasound assessment of rotator cuff tear repairability has a sensitivity of 86% (p tear size (p tear size ≥4 cm2 or anteroposterior tear length ≥25 mm indicated an irreparable rotator cuff tear. Conclusions Ultrasound assessment is accurate in predicting rotator cuff tear repairability. Tear size or anteroposterior tear length and age were the best predictors of repairability. PMID:27582996

  10. Hot tearing studies in AA5182

    Science.gov (United States)

    van Haaften, W. M.; Kool, W. H.; Katgerman, L.

    2002-10-01

    One of the major problems during direct chill (DC) casting is hot tearing. These tears initiate during solidification of the alloy and may run through the entire ingot. To study the hot tearing mechanism, tensile tests were carried out in semisolid state and at low strain rates, and crack propagation was studied in situ by scanning electron microscopy (SEM). These experimentally induced cracks were compared with hot tears developed in an AA5182 ingot during a casting trial in an industrial research facility. Similarities in the microstructure of the tensile test specimens and the hot tears indicate that hot tearing can be simulated by performing tensile tests at semisolid temperatures. The experimental data were compared with existing hot tearing models and it was concluded that the latter are restricted to relatively high liquid fractions because they do not take into account the existence of solid bridges in the crack.

  11. [Gases in vitreoretinal surgery].

    Science.gov (United States)

    Janco, L; Vida, R; Bartos, M; Villémová, K; Izák, M

    2012-02-01

    To evaluate the importance and benefits of using gases in vitreoretinal surgery. The gases represent a wide group of substances used in eye surgery for more than 100 years. The role of intraocular gases in vitreoretinal surgery is irreplaceable. Their use is still considered to be the "gold standard". An important step in eye surgery was the introduction of expanding gases--sulfur hexafluoride and perfluorocarbons into routine clinical practice. The most common indications for the use of intraocular gases are: retinal detachment, idiopathic macular hole, complications of vitreoretinal surgery and others. The introduction of intraocular gases into routine clinical practice, along with other modern surgical techniques resulted in significant improvement of postoperative outcomes in a wide range of eye diseases. Understanding the principles of intraocular gases use brings the benefits to the patient and physician as well. Due to their physical and chemical properties they pose far the best and most appropriate variant of intraocular tamponade. Gases also bring some disadvantages, such as difficulties in detailed fundus examination, visual acuity testing, ultrasonographic examination, difficulties in application of intravitreal drugs or reduced possibility of retina laser treatment. The gases significantly change optical system properties of the eye. The use of gases in vitreoretinal surgery has significantly increased success rate of retinal detachment surgery, complicated posterior segment cases, trauma, surgery of the macula and other diseases.

  12. TFOS DEWS II Tear Film Report.

    Science.gov (United States)

    Willcox, Mark D P; Argüeso, Pablo; Georgiev, Georgi A; Holopainen, Juha M; Laurie, Gordon W; Millar, Tom J; Papas, Eric B; Rolland, Jannick P; Schmidt, Tannin A; Stahl, Ulrike; Suarez, Tatiana; Subbaraman, Lakshman N; Uçakhan, Omür Ö; Jones, Lyndon

    2017-07-01

    The members of the Tear Film Subcommittee reviewed the role of the tear film in dry eye disease (DED). The Subcommittee reviewed biophysical and biochemical aspects of tears and how these change in DED. Clinically, DED is characterized by loss of tear volume, more rapid breakup of the tear film and increased evaporation of tears from the ocular surface. The tear film is composed of many substances including lipids, proteins, mucins and electrolytes. All of these contribute to the integrity of the tear film but exactly how they interact is still an area of active research. Tear film osmolarity increases in DED. Changes to other components such as proteins and mucins can be used as biomarkers for DED. The Subcommittee recommended areas for future research to advance our understanding of the tear film and how this changes with DED. The final report was written after review by all Subcommittee members and the entire TFOS DEWS II membership. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Artificial tears potpourri: a literature review

    Directory of Open Access Journals (Sweden)

    Moshirfar M

    2014-07-01

    Full Text Available Majid Moshirfar,1 Kasey Pierson,2,* Kamalani Hanamaikai,3,* Luis Santiago-Caban,1 Valliammai Muthappan,1 Samuel F Passi11Department of Ophthalmology, John A Moran Eye Center, University of Utah, Salt Lake City, UT, USA; 2University of Arizona College of Medicine, Phoenix, Phoenix, AZ, USA; 3A T Still University, School of Osteopathic Medicine in Arizona, Mesa, AZ, USA *These authors contributed equally to this work Abstract: Numerous brands and types of artificial tears are available on the market for the treatment of dysfunctional tear syndrome. Past literature has focused on comparing the components of these products on patient’s clinical improvement. The wide array of products on the market presents challenges to both clinicians and patients when trying to choose between available tear replacement therapies. Different formulations affect patients based on etiology and severity of disease. In order to provide an unbiased comparison between available tear replacement therapies, we conducted a literature review of existing studies and National Institutes of Health clinical trials on commercially available, brand name artificial tears. Outcomes evaluated in each study, as well as the percent of patients showing clinical and symptomatic improvement, were analyzed. Fifty-one studies evaluating different brands of artificial tears, and their efficacy were identified. Out of the 51 studies, 18 were comparison studies testing brand name artificial tears directly against each other. Nearly all formulations of artificial tears provided significant benefit to patients with dysfunctional tear syndrome, but some proved superior to others. From the study data, a recommended treatment flowchart was derived. Keywords: dry eye, tear film, dysfunctional tear syndrome, ophthalmic lubricant, artificial tears, lipid layer, tear osmolarity, TBUT, Systane®, Refresh®, Blink®, GenTeal®, Soothe®, Lacrisert®, ocular surface inflammatory disease, Sjogren

  14. Plate Tearing by a Cone

    DEFF Research Database (Denmark)

    Simonsen, Bo Cerup

    1998-01-01

    The present paper is concerned with steady-state plate tearing by a cone. This is a scenario where a cone is forced through a ductile metal plate with a constant lateral tip penetration in a motion in the plane of the plate. The considered process could be an idealisation of the damage, which...... as for the out-of-plane reaction force. (C) 1998 Elsevier Science Ltd. All rights reserved....

  15. Extraction with supercritical gases

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, G M; Wilke, G; Stahl, E

    1980-01-01

    The contents of this book derives from a symposium on the 5th and 6th of June 1978 in the ''Haus der Technik'' in Essen. Contributions were made to separation with supercritical gases, fluid extraction of hops, spices and tobacco, physicochemical principles of extraction, phase equilibria and critical curves of binary ammonia-hydrocarbon mixtures, a quick method for the microanalytical evaluation of the dissolving power of supercritical gases, chromatography with supercritical fluids, the separation of nonvolatile substances by means of compressed gases in countercurrent processes, large-scale industrial plant for extraction with supercritical gases, development and design of plant for high-pressure extraction of natural products.

  16. Handbook of purified gases

    CERN Document Server

    Schoen, Helmut

    2015-01-01

    Technical gases are used in almost every field of industry, science and medicine and also as a means of control by government authorities and institutions and are regarded as indispensable means of assistance. In this complete handbook of purified gases the physical foundations of purified gases and mixtures as well as their manufacturing, purification, analysis, storage, handling and transport are presented in a comprehensive way. This important reference work is accompanied with a large number of Data Sheets dedicated to the most important purified gases.  

  17. Gases in molten salts

    CERN Document Server

    Tomkins, RPT

    1991-01-01

    This volume contains tabulated collections and critical evaluations of original data for the solubility of gases in molten salts, gathered from chemical literature through to the end of 1989. Within the volume, material is arranged according to the individual gas. The gases include hydrogen halides, inert gases, oxygen, nitrogen, hydrogen, carbon dioxide, water vapor and halogens. The molten salts consist of single salts, binary mixtures and multicomponent systems. Included also, is a special section on the solubility of gases in molten silicate systems, focussing on slags and fluxes.

  18. Tear and decohesion of bovine pericardial tissue.

    Science.gov (United States)

    Tobaruela, Almudena; Elices, Manuel; Bourges, Jean Yves; Rojo, Francisco Javier; Atienza, José Miguel; Guinea, Gustavo

    2016-10-01

    The aim of this study was to evaluate quantitatively the fracture-by tear and delamination-of bovine pericardium tissues which are usually employed for the manufacture of bioprosthetic valves. A large number of samples (77) were tested in root-to-apex and circumferential directions, according to a standardised tear test (ASTM D 1938). Before performing the tear test, some samples were subjected to 1000 cycles of fatigue to a maximum stress of 3MPa. Fracture toughness of tearing and delamination were computed by following a simple fracture model. The study showed significantly lower values of delamination toughness compared with tear delamination. Moreover, tear forces were different in each test direction, revealing a clear orthotropic behaviour. All these results, as well as the testing procedure, could be of value for future research in the physiological function of pericardium tissues and clinical applications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Tearing mode saturation with finite pressure

    International Nuclear Information System (INIS)

    Lee, J.K.

    1988-01-01

    With finite pressure, the saturation of the current-driven tearing mode is obtained in three-dimensional nonlinear resistive magnetohydrodynamic simulations for Tokamak plasmas. To effectively focus on the tearing modes, the perturbed pressure effects are excluded while the finite equilibrium pressure effects are retained. With this model, the linear growth rates of the tearing modes are found to be very insensitive to the equilibrium pressure increase. The nonlinear aspects of the tearing modes, however, are found to be very sensitive to the pressure increase in that the saturation level of the nonlinear harmonics of the tearing modes increases monotonically with the pressure rise. The increased level is associated with enhanced tearing island sizes or increased stochastic magnetic field region. (author)

  20. MRI of meniscal bucket-handle tears

    Energy Technology Data Exchange (ETDEWEB)

    Magee, T.H.; Hinson, G.W. [Menorah Medical Center, Overland Park, KS (United States). Dept. of Radiology

    1998-09-01

    A meniscal bucket-handle tear is a tear with an attached fragment displaced from the meniscus of the knee joint. Low sensitivity of MRI for detection of bucket-handle tears (64% as compared with arthroscopy) has been reported previously. We report increased sensitivity for detecting bucket-handle tears with the use of coronal short tau inversion recovery (STIR) images. Results. By using four criteria for diagnosis of meniscal bucket-handle tears, our overall sensitivity compared with arthroscopy was 93% (28 of 30 meniscal bucket-handle tears seen at arthroscopy were detected by MRI). The meniscal fragment was well visualized in all 28 cases on coronal STIR images. The double posterior cruciate ligament sign was seen in 8 of 30 cases, the flipped meniscus was seen in 10 of 30 cases and a fragment in the intercondylar notch was seen in 18 of 30 cases. (orig.)

  1. Percentage Level of Tannin fur Rabbit for Leather Concerning Stitch Tearing Strength, Tearing Strength and Flexibility

    OpenAIRE

    Mustakim Mustakim; Aris Sri Widati; Lisa Purnaningtyas

    2012-01-01

    The purpose of this study was to find out the appropriate of tannin level for rabbit fur leather concerning stitch tearing strength, tearing strength, and flexibility. The result were expected to contribute good information for the society, leather craftsman, and further researchers about fur leather tanning especially rabbit fur leather with tannin concerning stitch tearing strength, tearing strength and flexibility. The material that used were 12 pieces of four months of rabbit skin. The re...

  2. Tear clearance implications for ocular surface health.

    Science.gov (United States)

    de Paiva, Cintia Sade; Pflugfelder, Stephen C

    2004-03-01

    Tear clearance/turnover provides a global assessment of the function of the lacrimal functional unit and of tear exchange on the ocular surface. It is an indirect measure of dry eye induced inflammation on the ocular surface. It shows better correlation with the severity of ocular irritation symptoms and corneal epithelial disease in dry eye than the Schirmer 1 test. Delayed tear clearance may prove to be the best measure for identifying patients with tear film disorders who may respond to anti-inflammatory therapy.

  3. Artificial tears potpourri: a literature review

    Science.gov (United States)

    Moshirfar, Majid; Pierson, Kasey; Hanamaikai, Kamalani; Santiago-Caban, Luis; Muthappan, Valliammai; Passi, Samuel F

    2014-01-01

    Numerous brands and types of artificial tears are available on the market for the treatment of dysfunctional tear syndrome. Past literature has focused on comparing the components of these products on patient’s clinical improvement. The wide array of products on the market presents challenges to both clinicians and patients when trying to choose between available tear replacement therapies. Different formulations affect patients based on etiology and severity of disease. In order to provide an unbiased comparison between available tear replacement therapies, we conducted a literature review of existing studies and National Institutes of Health clinical trials on commercially available, brand name artificial tears. Outcomes evaluated in each study, as well as the percent of patients showing clinical and symptomatic improvement, were analyzed. Fifty-one studies evaluating different brands of artificial tears, and their efficacy were identified. Out of the 51 studies, 18 were comparison studies testing brand name artificial tears directly against each other. Nearly all formulations of artificial tears provided significant benefit to patients with dysfunctional tear syndrome, but some proved superior to others. From the study data, a recommended treatment flowchart was derived. PMID:25114502

  4. Divalent cations in tears, and their influence on tear film stability in humans and rabbits.

    Science.gov (United States)

    Wei, Xiaojia Eric; Markoulli, Maria; Millar, Thomas J; Willcox, Mark D P; Zhao, Zhenjun

    2012-06-05

    Reduced tear film stability is reported to contribute to dry eye. Rabbits are known to have a more stable tear film than humans. Thus, we sought to examine the tears of rabbits and humans for metal cations, and to test how they influence tear film stability. Tears were collected from 10 healthy humans and 6 rabbits. Tear osmolality was measured by vapor pressure osmometer, and metals analyzed using inductively coupled plasma (ICP) mass spectrometry or ICP atomic emission spectroscopy. The influence of divalent cations on tears was analyzed by measuring surface tension using the Langmuir trough in vitro, using different concentrations of cations in the subphase, and grading the tear break-up in rabbits in vivo after instillation of chelating agents. Rabbit tears had a higher osmolality compared to humans. Major metals did not differ between species; however, rabbits had higher levels of Mg(2+) (1.13 vs. 0.39 mM) and Ca(2+) (0.75 vs. 0.36 mM). In rabbit tears in vitro, diminishing divalent cations resulted in a decrease in the maximum surface pressure from 37 to 30 mN/m. In vivo, an increase in the amount of tear film that was broken-up was found. In contrast, when changing divalent cation concentrations in human tears, the maximum surface pressure remained at 26 mN/m. The normal osmolality of rabbit tears is significantly higher than that in humans. While divalent cations had little influence on human tears, they appear to have an important role in maintaining tear film stability in rabbits.

  5. A review on hot tearing of magnesium alloys

    Directory of Open Access Journals (Sweden)

    Jiangfeng Song

    2016-09-01

    Full Text Available Hot tearing is often a major casting defect in magnesium alloys and has a significant impact on the quality of their casting products. Hot tearing of magnesium alloys is a complex solidification phenomenon which is still not fully understood, it is of great importance to investigate the hot tearing behaviour of magnesium alloys. This review attempts to summarize the investigations on hot tearing of magnesium alloys over the past decades. The hot tearing criteria including recently developed Kou's criterion are summarized and compared. The numeric simulation and assessing methods of hot tearing, factors influencing hot tearing, and hot tearing susceptibility (HTS of magnesium alloys are discussed.

  6. Influence of Ophthalmic Solutions on Tear Components.

    Science.gov (United States)

    Shigeyasu, Chika; Yamada, Masakazu; Akune, Yoko

    2016-11-01

    Tear fluids are a mixture of secretions derived from lacrimal glands, accessory lacrimal glands, conjunctiva, and meibomian glands. Compositional changes to tears occur in the normal state and during ocular surface disease, such as dry eye conditions. We have investigated compositional changes to tears after topical application of ophthalmic solutions, with regard to tear-specific proteins (secretory immunoglobulin A, lactoferrin, lipocalin-1, and lysozyme) and ocular surface mucin in normal and dry eye conditions using high-performance liquid chromatography. After application of saline solution (0.9% sodium chloride) in normal subjects, transient but significant decreases in all tear components were observed. The recovery of protein concentrations took up to 30 minutes and lasted longer when the saline solution was applied more frequently. When applying ophthalmic solutions, a balance between washout and dilutional effects should be considered in addition to the therapeutic effect. Investigation of the effect of diquafosol solution (3%) in normal subjects revealed a significant increase in sialic acid concentration, a marker of ocular mucin, at 5 minutes after application, whereas a significant decrease was observed with saline. This result indicates the accelerated secretion of mucin from ocular tissues induced by diquafosol. A clinical study to determine the efficacy of diquafosol in patients with dry eye revealed improvements in tear breakup time, keratoconjunctival staining scores, and Schirmer test score, accompanied by an increase in sialic acid concentration in tears. Investigating normal and dry eye conditions through tear analysis may clarify the pathophysiology of dry eye conditions and support the efficacy of treatments.

  7. The social impact of emotional tears

    NARCIS (Netherlands)

    Vingerhoets, A.J.J.M.; van de Ven, N.; van der Velden, Y.

    2016-01-01

    The question what specific functions the production of emotional tears fulfills has received only limited attention of behavioral scientists. We report the results of two studies on the social impact of emotional tears. In Study 1 (96 Dutch females), perceived helplessness and felt connectedness

  8. Detecting meniscal tears in primary care

    NARCIS (Netherlands)

    Snoeker, B.A.M.

    2017-01-01

    Although meniscal tears are a very common phenomenon uncertainty exists about the diagnosis and treatment of meniscal tears in primary care. This thesis aims to provide evidence for general practitioners and physical therapists regarding the diagnosis and management of patients with a suspected

  9. Interferometric characterization of tear film dynamics

    Science.gov (United States)

    Primeau, Brian Christopher

    The anterior refracting surface of the eye is the thin tear film that forms on the surface of the cornea. When a contact lens is on worn, the tear film covers the contact lens as it would a bare cornea, and is affected by the contact lens material properties. Tear film irregularity can cause both discomfort and vision quality degradation. Under normal conditions, the tear film is less than 10 microns thick and the thickness and topography change in the time between blinks. In order to both better understand the tear film, and to characterize how contact lenses affect tear film behavior, two interferometers were designed and built to separately measure tear film behavior in vitro and in vivo. An in vitro method of characterizing dynamic fluid layers applied to contact lenses mounted on mechanical substrates has been developed using a phase-shifting Twyman-Green interferometer. This interferometer continuously measures light reflected from the surface of the fluid layer, allowing precision analysis of the dynamic fluid layer. Movies showing this fluid layer behavior can be generated. The fluid behavior on the contact lens surface is measured, allowing quantitative analysis beyond what typical contact angle or visual inspection methods provide. The in vivo interferometer is a similar system, with additional modules included to provide capability for human testing. This tear film measurement allows analysis beyond capabilities of typical fluorescein visual inspection or videokeratometry and provides better sensitivity and resolution than shearing interferometry methods.

  10. Tear exchange and contact lenses: a review.

    Science.gov (United States)

    Muntz, Alex; Subbaraman, Lakshman N; Sorbara, Luigina; Jones, Lyndon

    2015-01-01

    Tear exchange beneath a contact lens facilitates ongoing fluid replenishment between the ocular surface and the lens. This exchange is considerably lower during the wear of soft lenses compared with rigid lenses. As a result, the accumulation of tear film debris and metabolic by-products between the cornea and a soft contact lens increases, potentially leading to complications. Lens design innovations have been proposed, but no substantial improvement in soft lens tear exchange has been reported. Researchers have determined post-lens tear exchange using several methods, notably fluorophotometry. However, due to technological limitations, little remains known about tear hydrodynamics around the lens and, to-date, true tear exchange with contact lenses has not been shown. Further knowledge regarding tear exchange could be vital in aiding better contact lens design, with the prospect of alleviating certain adverse ocular responses. This article reviews the literature to-date on the significance, implications and measurement of tear exchange with contact lenses. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  11. Deltoid muscle and tendon tears in patients with chronic rotator cuff tears

    International Nuclear Information System (INIS)

    Ilaslan, Hakan; Recht, Michael P.; Iannotti, Joseph P.

    2007-01-01

    To describe the magnetic resonance imaging (MRI) appearances of tears of the deltoid muscle and tendon in patients with rotator cuff tears and without a prior history of shoulder surgery. Deltoid tears diagnosed on MR examinations were prospectively recorded between February 2003 through June 2004. The images of these patients were then retrospectively reviewed to determine the location of the deltoid tear, the presence of rotator cuff tears, tendon retraction, muscle atrophy, degree of humeral head subluxation, bony erosive changes involving the undersurface of the acromion, and the presence of edema or fluid-like signal intensity in the deltoid muscle and overlying subcutaneous tissues. There were 24 (0.3%) patients with deltoid tears; nine men and 15 women. The age range was 54 to 87 (average 73) years. The right side was involved in 20 cases, and the left in four cases. Fifteen patients had full thickness and nine had partial thickness tears of the deltoid. Shoulder pain was the most common presenting symptom. The physical examination revealed a defect in the region of the deltoid in two patients. Nineteen patients had tears in the muscle belly near the musculotendinous junction, and five had avulsion of the tendon from the acromial origin. Full thickness rotator cuff tears were present in all of the patients, and 22 patients had associated muscle atrophy. Subcutaneous edema and fluid-like signal was present in 15 patients. Tears of the deltoid muscle or tendon is an unusual finding, but they can be seen in patients with chronic massive rotator cuff tears. Partial thickness tears tend to involve the undersurface of the deltoid muscle and tendon. Associated findings such as intramuscular cyst or ganglion in the deltoid muscle belly and subcutaneous edema or fluid-like signal overlying the deltoid in a patient with a rotator cuff tear should raise the suspicion of a deltoid tear. (orig.)

  12. Deltoid muscle and tendon tears in patients with chronic rotator cuff tears

    Energy Technology Data Exchange (ETDEWEB)

    Ilaslan, Hakan; Recht, Michael P. [Cleveland Clinic, Musculoskeletal Radiology/A21, Division of Radiology, Cleveland, OH (United States); Iannotti, Joseph P. [Cleveland Clinic, Department of Orthopedic Surgery, Cleveland, OH (United States)

    2007-06-15

    To describe the magnetic resonance imaging (MRI) appearances of tears of the deltoid muscle and tendon in patients with rotator cuff tears and without a prior history of shoulder surgery. Deltoid tears diagnosed on MR examinations were prospectively recorded between February 2003 through June 2004. The images of these patients were then retrospectively reviewed to determine the location of the deltoid tear, the presence of rotator cuff tears, tendon retraction, muscle atrophy, degree of humeral head subluxation, bony erosive changes involving the undersurface of the acromion, and the presence of edema or fluid-like signal intensity in the deltoid muscle and overlying subcutaneous tissues. There were 24 (0.3%) patients with deltoid tears; nine men and 15 women. The age range was 54 to 87 (average 73) years. The right side was involved in 20 cases, and the left in four cases. Fifteen patients had full thickness and nine had partial thickness tears of the deltoid. Shoulder pain was the most common presenting symptom. The physical examination revealed a defect in the region of the deltoid in two patients. Nineteen patients had tears in the muscle belly near the musculotendinous junction, and five had avulsion of the tendon from the acromial origin. Full thickness rotator cuff tears were present in all of the patients, and 22 patients had associated muscle atrophy. Subcutaneous edema and fluid-like signal was present in 15 patients. Tears of the deltoid muscle or tendon is an unusual finding, but they can be seen in patients with chronic massive rotator cuff tears. Partial thickness tears tend to involve the undersurface of the deltoid muscle and tendon. Associated findings such as intramuscular cyst or ganglion in the deltoid muscle belly and subcutaneous edema or fluid-like signal overlying the deltoid in a patient with a rotator cuff tear should raise the suspicion of a deltoid tear. (orig.)

  13. Tearing mode instability due to anomalous resistivity

    International Nuclear Information System (INIS)

    Furuya, Atsushi; Itoh, Sanae I.; Yagi, Masatoshi

    2000-01-01

    Tearing mode instability in the presence of microscopic truculence is investigates. The effects of microscopic turbulence on tearing mode are taken as drags which are calculated by one-point renormalization method and mean-field approximation. These effects are reduced to effective diffusivities in reduced MHD equations. Using these equations, the stability analyses of the tearing mode are performed. It is shown that a finite amplitude of fluctuation enhances the growth rate of tearing mode. For very high values of turbulent diffusivities, marginally stable state exists. The effects of each turbulent diffusivity on mode stability are examined near marginal stability boundary. Parameter dependence of the resistive ballooning mode turbulence on tearing mode is analyzed as an example. (author)

  14. Kinetic theory of gases

    CERN Document Server

    Kauzmann, Walter

    2012-01-01

    Monograph and text supplement for first-year students of physical chemistry focuses chiefly on the molecular basis of important thermodynamic properties of gases, including pressure, temperature, and thermal energy. 1966 edition.

  15. AC BREAKDOWN IN GASES

    Science.gov (United States)

    electron- emission (multipactor) region, and (3) the low-frequency region. The breakdown mechanism in each of these regions is explained. An extensive bibliography on AC breakdown in gases is included.

  16. Reale Gase, tiefe Temperaturen

    Science.gov (United States)

    Heintze, Joachim

    Wir werden uns in diesem Kapitel zunächst mit der van der Waals'schen Zustandsgleichung befassen. In dieser Gleichung wird versucht, die Abweichungen, die reale Gase vom Verhalten idealer Gase zeigen, durch physikalisch motivierte Korrekturterme zu berücksichtigen. Es zeigt sich, dass die van derWaals-Gleichung geeignet ist, nicht nur die Gasphase, sondern auch die Phänomene bei der Verflüssigung von Gasen und den kritischen Punkt zu beschreiben.

  17. Gases in uranium exploration

    International Nuclear Information System (INIS)

    Wright, R.J.; Pacer, J.C.

    1981-01-01

    Interest continues to grow in the use of helium and radon detection as a uranium exploration tool because, in many instances, these radiogenic gases are the only indicators of deeply buried mineralization. The origin of these gases, their migration in the ground, the type of samples and measurement techniques are discussed. Case histories of comparative tests conducted on known uranium deposits at three geologically diverse sites in the United States of America are also presented. (author)

  18. Percentage Level of Tannin fur Rabbit for Leather Concerning Stitch Tearing Strength, Tearing Strength and Flexibility

    Directory of Open Access Journals (Sweden)

    Mustakim Mustakim

    2012-02-01

    Full Text Available The purpose of this study was to find out the appropriate of tannin level for rabbit fur leather concerning stitch tearing strength, tearing strength, and flexibility. The result were expected to contribute good information for the society, leather craftsman, and further researchers about fur leather tanning especially rabbit fur leather with tannin concerning stitch tearing strength, tearing strength and flexibility. The material that used were 12 pieces of four months of rabbit skin. The research method was Completely Randomized Design, consist of three treatments of tannin, they were: M1 (mimosa 15%, M2 (mimosa 20%, and M3 (mimosa 25%. Each of treatment hold on four repetition, the variables which measured were stitch tearing strength, tearing strength, and flexibility of fur leather. Data were  analysed by analysis variance followed by Duncan’s Multiple Range Test. The result of this research indicate that the use level of tannin give significant influence (P<0.05 among stitch tearing strength, tearing strength. It gave a very significant influence (P<0.01 for flexibility of rabbit fur leather. Based on the result, can be concluded that 25 % of tannin (mimosa, produce the best  result on stitch tearing strength and tearing strength. The increase of tannin offer will decrease the flexibility of fur leather but the lowest tannin produced the best flexibility of fur leather (15 percent. The best quality of rabbit fur leather produced by 25 % of tannin.   Keywords : leather, tannin, quality

  19. Mass spectrometric identification of phospholipids in human tears and tear lipocalin.

    Science.gov (United States)

    Dean, Austin W; Glasgow, Ben J

    2012-04-02

    The purpose of this article was to identify by mass spectrometry phosphocholine lipids in stimulated human tears and determine the molecules bound to tear lipocalin or other proteins. Tear proteins were separated isocratically from pooled stimulated human tears by gel filtration fast performance liquid chromatography. Separation of tear lipocalin was confirmed by SDS tricine gradient PAGE. Protein fractions were extracted with chloroform/methanol and analyzed with electrospray ionization MS/MS triple quadrupole mass spectrometry in precursor ion scan mode for select leaving groups. For quantification, integrated ion counts were derived from standard curves of authentic compounds of phosphatidylcholine (PC) and phosphatidylserine. Linear approximation was possible from integration of the mass spectrometrically obtained ion peaks at 760 Da for the PC standard. Tears contained 194 ng/mL of the major intact PC (34:2), m/z 758.6. Ten other monoisotopic phosphocholines were found in tears. A peak at 703.3 Da was assigned as a sphingomyelin. Four lysophosphatidylcholines (m/z 490-540) accounted for about 80% of the total integrated ion count. The [M+H](+) compound, m/z 496.3, accounted for 60% of the signal intensity. Only the tear lipocalin-bearing fractions showed phosphocholines (104 ng/mL). Although the intact phospholipids bound to tear lipocalin corresponded precisely in mass and relative signal intensity to that found in tears, we did not identify phosphocholines between m/z 490 and 540 in any of the gel-filtration fractions. Phospholipids, predominantly lysophospholipids, are present in tears. The higher mass intact PCs in tears are native ligands of tear lipocalin.

  20. Kinetic theory of tearing instability

    International Nuclear Information System (INIS)

    Hazeltine, R.D.; Dobrott, D.; Wang, T.S.

    1975-01-01

    The guiding-center kinetic equation with Fokker-Planck collision term is used to study, in cylindrical geometry, a class of dissipative instabilities of which the classical tearing mode is an archetype. Variational solution of the kinetic equation obviates the use of an approximate Ohm's law or adiabatic assumption, as used in previous studies, and it provides a dispersive relation which is uniformly valid for any ratio of wave frequency to collision frequency. One result of using the rigorous collision operator is the prediction of a new instability. This instability, driven by the electron temperature gradient, is predicted to occur under the long mean-free path conditions of present tokamak experiments, and has significant features in common with the kink-like oscillations observed in such experiments

  1. Tear ferning in normal dogs and dogs with keratoconjunctivitis sicca ...

    African Journals Online (AJOL)

    This study evaluates tear ferning as an ancillary technique for the evaluation of the canine tear film in normal eyes and eyes affected by keratoconjunctivitis sicca (KCS). Thirty dogs with KCS and 50 control dogs with normal tear film were evaluated with a full ophthalmoscopic examination and a Schirmer tear test type 1 ...

  2. US detection of rotator cuff tear

    International Nuclear Information System (INIS)

    Soble, M.G.; Guay, R.C.; Kaye, A.D.

    1988-01-01

    Between June 1986 and April 1988, 75 patients suspected of having a tear of the rotator cuff underwent shoulder sonography and arthrography. Compared with anthrography, US demonstrated 92% of rotor cuff tears, with a specificity of 84% and a negative predictive value of 95%. In 30 patients who underwent surgery for a rotator cuff tear or other soft-tissue abnormality, sonography demonstrated a sensitivity of 93% and specificity of 73%, while arthrography demonstrated a sensitivity of 87% and specificity of 100%. The above data indicate that US is a useful, noninvasive screening procedure for patients suspected of having rotator cuff injury

  3. Classification of ulnar triangular fibrocartilage complex tears. A treatment algorithm for Palmer type IB tears.

    Science.gov (United States)

    Atzei, A; Luchetti, R; Garagnani, L

    2017-05-01

    The classical definition of 'Palmer Type IB' triangular fibrocartilage complex tear, includes a spectrum of clinical conditions. This review highlights the clinical and arthroscopic criteria that enable us to categorize five classes on a treatment-oriented classification system of triangular fibrocartilage complex peripheral tears. Class 1 lesions represent isolated tears of the distal triangular fibrocartilage complex without distal radio-ulnar joint instability and are amenable to arthroscopic suture. Class 2 tears include rupture of both the distal triangular fibrocartilage complex and proximal attachments of the triangular fibrocartilage complex to the fovea. Class 3 tears constitute isolated ruptures of the proximal attachment of the triangular fibrocartilage complex to the fovea; they are not visible at radio-carpal arthroscopy. Both Class 2 and Class 3 tears are diagnosed with a positive hook test and are typically associated with distal radio-ulnar joint instability. If required, treatment is through reattachment of the distal radio-ulnar ligament insertions to the fovea. Class 4 lesions are irreparable tears due to the size of the defect or to poor tissue quality and, if required, treatment is through distal radio-ulnar ligament reconstruction with tendon graft. Class 5 tears are associated with distal radio-ulnar joint arthritis and can only be treated with salvage procedures. This subdivision of type IB triangular fibrocartilage complex tear provides more insights in the pathomechanics and treatment strategies. II.

  4. Electrostatic effect for the collisionless tearing mode

    International Nuclear Information System (INIS)

    Hoshino, M.

    1987-01-01

    Electron dynamics has not been self-consistently considered in collisionless tearing mode theories to date because of the mathematical complexity of the Vlasov-Maxwell equations. We have found using computer simulations that electrostatic fields play an important role in the tearing mode. Vlasov theory, including the electrostatic field, is investigated for topologies with both antiparallel and nonantiparallel magnetic field lines. The electrostatic field influences the resonant current in the neutral sheet which is a non-MHD effect, and modifies the linear growth rate. At the magnetopause, where the field lines are not antiparallel, the electrostatic effect acts to raise the linear growth rate of the tearing mode. On the other hand, in the magnetotail, where magnetic field lines are antiparallel, the electrostatic effect reduces the tearing mode growth rate. copyright American Geophysical Union 1987

  5. Partial Thickness Rotator Cuff Tears: Current Concepts

    Science.gov (United States)

    Matthewson, Graeme; Beach, Cara J.; Nelson, Atiba A.; Woodmass, Jarret M.; Ono, Yohei; Boorman, Richard S.; Lo, Ian K. Y.; Thornton, Gail M.

    2015-01-01

    Partial thickness rotator cuff tears are a common cause of pain in the adult shoulder. Despite their high prevalence, the diagnosis and treatment of partial thickness rotator cuff tears remains controversial. While recent studies have helped to elucidate the anatomy and natural history of disease progression, the optimal treatment, both nonoperative and operative, is unclear. Although the advent of arthroscopy has improved the accuracy of the diagnosis of partial thickness rotator cuff tears, the number of surgical techniques used to repair these tears has also increased. While multiple repair techniques have been described, there is currently no significant clinical evidence supporting more complex surgical techniques over standard rotator cuff repair. Further research is required to determine the clinical indications for surgical and nonsurgical management, when formal rotator cuff repair is specifically indicated and when biologic adjunctive therapy may be utilized. PMID:26171251

  6. Role of ultrasound in rotator cuff tears

    International Nuclear Information System (INIS)

    Siddiqi, H.A.; Mirza, T.

    2010-01-01

    The study was designed to evaluate the efficacy of ultrasound in rotator cuff tears and to compare it with MRI. Total number of patients was thirty. All of these were above thirty years of age and were referred by clinicians, with shoulder pain for diagnostic workup. Post operative patients were excluded. Ultrasound and Magnetic Resonance Imaging (MRI) were performed on each patient. Same operator performed ultrasound in all patients. Ultrasound (US) and Magnetic Resonance Imaging (MRI) detected equal number of full thickness tears while two partial thickness tears were missed on US. Hypoechoic defect was the most important primary sign while cortical irregularity and fluid in subacromial and subdeltroid busra were the most important secondary signs on US. US was equally effective to MRI in detection of rotator cuff tears. It should be the primary investigation because of its availability, cost effective and real time evaluation provided significant expertise is developed, as it is highly operator dependent. (author)

  7. Influence of toroidal rotation on tearing modes

    Science.gov (United States)

    Cai, Huishan; Cao, Jintao; Li, Ding

    2017-10-01

    Tearing modes stability analysis including toroidal rotation is studied. It is found that rotation affects the stability of tearing modes mainly through the interaction with resistive inner region of tearing mode. The coupling of magnetic curvature with centrifugal force and Coriolis force provides a perturbed perpendicular current, and a return parallel current is induced to affect the stability of tearing modes. Toroidal rotation plays a stable role, which depends on the magnitude of Mach number and adiabatic index Γ, and is independent on the direction of toroidal rotation. For Γ >1, the scaling of growth rate is changed for typical Mach number in present tokamaks. For Γ = 1 , the scaling keeps unchanged, and the effect of toroidal rotation is much less significant, compared with that for Γ >1. National Magnetic Confinement Fusion Science Program and National Science Foundation of China under Grants No. 2014GB106004, No. 2013GB111000, No. 11375189, No. 11075161 and No. 11275260, and Youth Innovation Promotion Association CAS.

  8. An Athlete's Nightmare: Tearing the ACL

    Science.gov (United States)

    ... on the balls of their feet. "If the calf muscles are not absorbing the force, and if the knee is not in the proper position, the knee buckles and tears the ACL," explains Dr. Boden. After her initial ...

  9. Partial Thickness Rotator Cuff Tears: Current Concepts

    Directory of Open Access Journals (Sweden)

    Graeme Matthewson

    2015-01-01

    Full Text Available Partial thickness rotator cuff tears are a common cause of pain in the adult shoulder. Despite their high prevalence, the diagnosis and treatment of partial thickness rotator cuff tears remains controversial. While recent studies have helped to elucidate the anatomy and natural history of disease progression, the optimal treatment, both nonoperative and operative, is unclear. Although the advent of arthroscopy has improved the accuracy of the diagnosis of partial thickness rotator cuff tears, the number of surgical techniques used to repair these tears has also increased. While multiple repair techniques have been described, there is currently no significant clinical evidence supporting more complex surgical techniques over standard rotator cuff repair. Further research is required to determine the clinical indications for surgical and nonsurgical management, when formal rotator cuff repair is specifically indicated and when biologic adjunctive therapy may be utilized.

  10. Tearing mode analysis in tokamaks, revisited

    International Nuclear Information System (INIS)

    Nishimura, Y.; Callen, J.D.; Hegna, C.C.

    1997-12-01

    A new Δ' shooting code has been developed to investigate tokamak plasma tearing mode stability in a cylinder and large aspect ratio (ε ≤ 0.25) toroidal geometries, neglecting toroidal mode coupling. A different computational algorithm is used (shooting out from the singular surface instead of into it) to resolve the strong singularities at the mode rational surface, particularly in the presence of finite pressure term. Numerical results compare favorably with Furth et al. results. The effects of finite pressure, which are shown to decrease Δ', are discussed. It is shown that the distortion of the flux surfaces by the Shafranov shift, which modifies the geometry metric element stabilizes the tearing mode significantly, even in a low β regime before the toroidal magnetic curvature effects come into play. Double tearing modes in toroidal geometries are examined as well. Furthermore, m ≥ 2 tearing mode stability criteria are compared with three dimensional initial value MHD simulation by the FAR code

  11. Efficacy of artificial tears for children xerophthalmia

    Directory of Open Access Journals (Sweden)

    Jie Yang

    2016-03-01

    Full Text Available AIM:To observe the efficacy and safety of artificial tears for children xerophthalmia.METHODS:Fifty-eight cases with 116 eyes were diagnosed as xerophthalmia by tear break-up time(BUT, Schirmer Ⅰ test(SⅠt, tear meniscus height, corneal staining, meibomian gland function test and were given artificial tears therapy for 1mo. Then the aforementioned tests were conducted again for statistical analysis.RESULTS:The mean BUT of all the children before treatments was 6.03±1.19s, SⅠt was 7.67±2.32mm/5min, tear meniscus height was 0.20±0.02mm, corneal staining was 1.02±0.13 scores and meibomian gland function was 2.45±0.86 scores. Sixty-two eyes in 31 cases were the lipid-deficient type, 40 eyes in 20 cases were aqueous-deficient type, and 14 eyes in 7 cases were other types. According to their types, corresponding artificial tears therapy was given. At 1mo after treatments, the clinical symptoms were improved significantly. BUT was 13.72±1.83s, SⅠt was 12.38±3.64mm/5min, tear meniscus height was 0.36±0.08mm, corneal fluorescein staining was 0.03±0.24 scores and meibomian gland function was 1.57±0.93 scores. Compared with those before treatments, the difference of each observed indicators was statistically significant(PCONCLUSION:Artificial tears treatment for children xerophthalmia is safe and effective.

  12. Ponderomotive modification of drift tearing modes

    International Nuclear Information System (INIS)

    Urquijo, G.; Singh, R.; Sen, A.

    1997-01-01

    The linear characteristics of drift tearing modes are investigated in the presence of a significant background of radio-frequency (RF) waves in the ion cyclotron range of frequencies. The ponderomotive force, arising from the radial gradients in the RF field energy, is found to significantly modify the inner layer solutions of the drift tearing modes. It can have a stabilizing influence, even at moderate RF powers, provided the field energy has a decreasing radial profile at the mode rational surface. (author)

  13. Human tears reveal insights into corneal neovascularization.

    Science.gov (United States)

    Zakaria, Nadia; Van Grasdorff, Sigi; Wouters, Kristien; Rozema, Jos; Koppen, Carina; Lion, Eva; Cools, Nathalie; Berneman, Zwi; Tassignon, Marie-José

    2012-01-01

    Corneal neovascularization results from the encroachment of blood vessels from the surrounding conjunctiva onto the normally avascular cornea. The aim of this study is to identify factors in human tears that are involved in development and/or maintenance of corneal neovascularization in humans. This could allow development of diagnostic tools for monitoring corneal neovascularization and combination monoclonal antibody therapies for its treatment. In an observational case-control study we enrolled a total of 12 patients with corneal neovascularization and 10 healthy volunteers. Basal tears along with reflex tears from the inferior fornix, superior fornix and using a corneal bath were collected along with blood serum samples. From all patients, ocular surface photographs were taken. Concentrations of the pro-angiogenic cytokines interleukin (IL)-6, IL-8, Vascular Endothelial Growth Factor (VEGF), Monocyte Chemoattractant Protein 1 (MCP-1) and Fas Ligand (FasL) were determined in blood and tear samples using a flow cytometric multiplex assay. Our results show that the concentration of pro-angiogenic cytokines in human tears are significantly higher compared to their concentrations in serum, with highest levels found in basal tears. Interestingly, we could detect a significantly higher concentration of IL- 6, IL-8 and VEGF in localized corneal tears of patients with neovascularized corneas when compared to the control group. This is the first study of its kind demonstrating a significant difference of defined factors in tears from patients with neovascularized corneas as compared to healthy controls. These results provide the basis for future research using animal models to further substantiate the role of these cytokines in the establishment and maintenance of corneal neovascularization.

  14. Neoclassical tearing modes in a tokamak

    International Nuclear Information System (INIS)

    Hahm, T.S.

    1988-08-01

    Linear tearing instability is studied in the banana collisionality regime in tokamak geometry. Neoclassical effects produce significant modifications of Ohm's law and the vorticity equation so that the growth rate of tearing modes driven by Δ' is dramatically reduced compared to the usual resistive MHD value. Consequences of this result, regarding the presence of pressure-gradient-driven neoclassical resistive interchange instabilities and the evolution of magnetic islands in the Rutherford regime, are discussed. 10 refs

  15. Thermal effects on tearing mode saturation

    International Nuclear Information System (INIS)

    Kim, J.S.; Chu, M.S.; Greene, J.M.

    1988-01-01

    The effect of geometry on tearing modes, saturated states of tearing modes, and the thermal effect on tearing modes are presented. The configuration of current and magnetic fields are quite different in slabs and in Tokamaks. However, for any magnetic island regardless of geometry and heating conditions, at island saturation the product of resistivity and current is the same at magnetic O and X lines. The temperature perturbation effect on the nonlinear development of tearing modes is investigated. Thermal conduction along the field lines is much faster than that in the perpendicular direction, and thus the temperature profile follows the island structure. Utilizing Spitzer's conductivity relation, the temperature perturbation is modelled as helical components of resistivity. For a usual tearing mode unstable Tokamak, where shear is positive, the islands continue to grow to a larger size when the islands are cooled. When they are heated, the island sizes are reduced. The temperature perturbation can induce islands even for equilibria stable with respect to tearing modes. Again, the islands appear when cooling takes place. The equilibria with the cooled islands show enhanced field line stochasticity, thus enhanced heat transport. Therefore, thermal instability can be directly related to pressure disruptions. (author)

  16. Tear film measurement by optical reflectometry technique

    Science.gov (United States)

    Lu, Hui; Wang, Michael R.; Wang, Jianhua; Shen, Meixiao

    2014-01-01

    Abstract. Evaluation of tear film is performed by an optical reflectometer system with alignment guided by a galvanometer scanner. The reflectometer system utilizes optical fibers to deliver illumination light to the tear film and collect the film reflectance as a function of wavelength. Film thickness is determined by best fitting the reflectance-wavelength curve. The spectral reflectance acquisition time is 15 ms, fast enough for detecting film thickness changes. Fast beam alignment of 1 s is achieved by the galvanometer scanner. The reflectometer was first used to evaluate artificial tear film on a model eye with and without a contact lens. The film thickness and thinning rate have been successfully quantified with the minimum measured thickness of about 0.3 μm. Tear films in human eyes, with and without a contact lens, have also been evaluated. A high-contrast spectral reflectance signal from the precontact lens tear film is clearly observed, and the thinning dynamics have been easily recorded from 3.69 to 1.31 μm with lipid layer thickness variation in the range of 41 to 67 nm. The accuracy of the measurement is better than ±0.58% of the film thickness at an estimated tear film refractive index error of ±0.001. The fiber-based reflectometer system is compact and easy to handle. PMID:24500519

  17. Tear ferning test in healthy dogs.

    Science.gov (United States)

    Oriá, Arianne P; Raposo, Ana Claudia S; Araújo, Nayone L L C; Lima, Felipe B; Masmali, Ali M

    2017-11-07

    To evaluate and compare three tear sampling methods using two grading scales for administering the tear ferning test (TFT) to healthy dogs. In total, 90 dogs (180 eyes) were subjected to tear sampling using millimetered strips, reused after the Schirmer tear test (STT) (Schirmer group, SG). Then, the dogs were subdivided into three groups according to sampling approach: micropipette (MPG), microcapillary (MCG), and Schirmer sample 2 (S2G). The collected tears were dried on a clean microscope glass slide at room temperature and humidity. The ferning patterns were observed under a polarized light microscope and classified according to the Rolando and Masmali grading scales. Although all three methods were feasible, the STT was easier to perform in clinical settings. Type I and Grade 1 were the most commonly observed (64.17% and 61.7%, respectively) regardless of collection method. There was no significant difference between the STT median values and the TFT classifications. The TFT is appropriate for dogs and can be performed using the three suggested sampling methods, with a higher frequency of Type I and Grade 1. Thus, it is possible to use both grading scales in the classification of tear ferning in dogs. © 2017 American College of Veterinary Ophthalmologists.

  18. Sonographic evaluation of digital annular pulley tears

    International Nuclear Information System (INIS)

    Martinoli, C.; Derchi, L.E.; Bianchi, S.; Garcia, J.F.; Nebiolo, M.

    2000-01-01

    Objective. To evaluate the sonographic (US) appearance of digital annular pulley (DAP) tears in high-level rock climbers. Design and patients. We performed a retrospective analysis of the US examinations of 16 high-level rock climbers with clinical signs of DAP lesions. MRI and surgical evaluation were performed in five and three patients respectively. The normal US and MRI appearances of DAP were evaluated in 40 and three normal fingers respectively. Results. Nine of 16 patients presented a DAP tear. In eight subjects (seven with complete tears involving the fourth finger and one the fifth finger), US diagnosis was based on the indirect sign of volar bowstringing of the flexor tendons. Injured pulleys were not appreciated by US. Tears concerned the A2 and A3 in six patients and the A3 and A4 in two patients. A2 pulley thickening and hypoechogenicity compatible with a partial tear was demonstrated in one patient. MRI and surgical data correlated well with the US findings. Four patients had tenosynovitis of the flexor tendons but no evidence of pulley disruption. US examinations of three patients were normal. In the healthy subjects US demonstrated DAP in 16 of 40 digits. Conclusion. US can diagnose DAP tears and correlates with the MRI and surgical data. Because of its low cost and non-invasiveness we suggest US as the first imaging modality in the evaluation of injuries of the digital pulley. (orig.)

  19. Sonographic evaluation of digital annular pulley tears

    Energy Technology Data Exchange (ETDEWEB)

    Martinoli, C.; Derchi, L.E. [Istituto di Radiologia, Universita di Genova, Genoa (Italy); Bianchi, S.; Garcia, J.F. [Dept. de Radiologie, Hopital Cantonal Universitaire de Geneve (Switzerland); Nebiolo, M. [Reparto Pronto Soccorso Medico, Pietra Ligure (Italy)

    2000-07-01

    Objective. To evaluate the sonographic (US) appearance of digital annular pulley (DAP) tears in high-level rock climbers. Design and patients. We performed a retrospective analysis of the US examinations of 16 high-level rock climbers with clinical signs of DAP lesions. MRI and surgical evaluation were performed in five and three patients respectively. The normal US and MRI appearances of DAP were evaluated in 40 and three normal fingers respectively. Results. Nine of 16 patients presented a DAP tear. In eight subjects (seven with complete tears involving the fourth finger and one the fifth finger), US diagnosis was based on the indirect sign of volar bowstringing of the flexor tendons. Injured pulleys were not appreciated by US. Tears concerned the A2 and A3 in six patients and the A3 and A4 in two patients. A2 pulley thickening and hypoechogenicity compatible with a partial tear was demonstrated in one patient. MRI and surgical data correlated well with the US findings. Four patients had tenosynovitis of the flexor tendons but no evidence of pulley disruption. US examinations of three patients were normal. In the healthy subjects US demonstrated DAP in 16 of 40 digits. Conclusion. US can diagnose DAP tears and correlates with the MRI and surgical data. Because of its low cost and non-invasiveness we suggest US as the first imaging modality in the evaluation of injuries of the digital pulley. (orig.)

  20. MR imaging of rotator cuff tears

    International Nuclear Information System (INIS)

    Kumagai, Hideo

    1992-01-01

    A total of 115 patients with clinical symptoms and signs suggesting rotator cuff tears underwent MR imaging with a 1.5-Tesla system. The body coil was used as the receiver coil in 24 patients and a single 10 cm surface coil in 91. Arthrography or MR imaging with intra-articular Gd-DTPA (MR arthrography) was performed in 95 of the 115. T2-weighted images with the body coil showed high signal intensity lesions in rotator cuffs in only seven of the 10 patients who had tears demonstrated by arthrography or MR arthrography. On the other hand, T2-weighted images with the surface coil demonstrated high signal intensity lesions in cuffs in all 27 patients who were diagnosed to have tears by arthrography or MR arthrography. In 12 patietns, T2-wighted images with the surface coil showed high signal intensity lesions in cuffs, while arthrography and MR arthrography did not show tears. Surgery was performed in four of the 12 patients and partial tears were confirmed. A single 10 cm surface coil, 3 mm slice thickness and 2.5 second repetition time seem to account for the fine visualization of cuff tears by the T2-weighted images. These results suggest that T2-weighted images obtained with the surface coil are superior to arthrography and MR arthrography. (author)

  1. Magnetic resonance findings in skeletal muscle tears

    International Nuclear Information System (INIS)

    De Smet, A.A.

    1993-01-01

    Magnetic resonance (MR) images of skeletal muscle tears can clearly delineate the severity of muscle injury. Although MR imaging is seldom necessary in patients with acute musle trauma, it can be helpful in deciding on clinical management. The two major MR findings in acute muscle tears are deformity of the muscle and the presence of abnormal signal reflecting hemorrhage and edema. In acute tears, methemoglobin within the extravascular blood causes high-signal areas on both T1- and T2-weighted images. With partial tears, the blood may dissect in a distinctive linear pattern along the muscle bundles and fibers. As healing begins, the muscle signal diminishes, first on the T1-weighted images and then on the T2-weighted images. When there is residual abnormal signal on images obtained more than several months after the injury, it is presumed to represent hemorrhage from recurrent tears. In patients with a questionable history of a remote injury, the clinical presentation may be that of persistent pain or a soft tissue mass. In these cases MR imaging may identify the cause of the pain and can exclude a neoplasm by proving that the mass is a hypertrophied or retracted musle. Thus, MR imaging has a limited, but occasionally important role in selected patients with skeletal muscle tears. (orig.)

  2. Rotator cuff tear: A detailed update

    Directory of Open Access Journals (Sweden)

    Vivek Pandey

    2015-01-01

    Full Text Available Rotator cuff tear has been a known entity for orthopaedic surgeons for more than two hundred years. Although the exact pathogenesis is controversial, a combination of intrinsic factors proposed by Codman and extrinsic factors theorized by Neer is likely responsible for most rotator cuff tears. Magnetic resonance imaging remains the gold standard for the diagnosis of rotator cuff tears, but the emergence of ultrasound has revolutionized the diagnostic capability. Even though mini-open rotator cuff repair is still commonly performed, and results are comparable to arthroscopic repair, all-arthroscopic repair of rotator cuff tear is now fast becoming a standard care for rotator cuff repair. Appropriate knowledge of pathology and healing pattern of cuff, strong and biological repair techniques, better suture anchors, and gradual rehabilitation of postcuff repair have led to good to excellent outcome after repair. As the healing of degenerative cuff tear remains unpredictable, the role of biological agents such as platelet-rich plasma and stem cells for postcuff repair augmentation is still under evaluation. The role of scaffolds in massive cuff tear is also being probed.

  3. Diet, nutraceuticals and the tear film.

    Science.gov (United States)

    Jalbert, Isabelle

    2013-12-01

    Nutrition disorders and their correlates such as obesity are increasingly prevalent worldwide. A number of studies to date have suggested numerous potential associations between diet and tear film health; this paper will provide a summary of the available literature. The tear film is characterized through its protein and lipid content and through clinical measurements of characteristics such as osmolarity, volume and stability. Malnutrition, protein and vitamin-A deficiencies are extremely deleterious to tear film health and supplementation with oral vitamin A in this setting is of clear benefit. The relative impact of diet on tear film within what would be considered normal ranges of consumption is less clear. A number of population studies have suggested that hyperlipidemia and a diet low in omega-3 fatty acids are risks factor for dry eye disease. Numerous studies have investigated the effectiveness of oral supplementation with antioxidants, omega-3 (e.g. fish oil and linseed oil) and omega-6 (e.g. evening primrose oil) fatty acids in the last 10 years. Taken together, these suggest a small benefit of oral supplementation on tear film volume, stability and decreased ocular symptoms in patients previously diagnosed with diseases involving the ocular surface (e.g. Sjögren's syndrome, meibomian gland dysfunction, dry eye disease) and contact lens wearers suffering from dry eye. More research is required to determine the exact composition, dosage and indications for their use and to fully characterize how these nutraceuticals modulate the tear film. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Tear-Film Evaporation Rate from Simultaneous Ocular-Surface Temperature and Tear-Breakup Area.

    Science.gov (United States)

    Dursch, Thomas J; Li, Wing; Taraz, Baseem; Lin, Meng C; Radke, Clayton J

    2018-01-01

    A corneal heat-transfer model is presented to quantify simultaneous measurements of fluorescein tear-breakup area (TBA) and ocular-surface temperature (OST). By accounting for disruption of the tear-film lipid layer (TFLL), we report evaporation rates through lipid-covered tear. The modified heat-transfer model provides new insights into evaporative dry eye. A quantitative analysis is presented to assess human aqueous tear evaporation rate (TER) through intact TFLLs from simultaneous in vivo measurement of time-dependent infrared OST and fluorescein TBA. We interpret simultaneous OST and TBA measurements using an extended heat-transfer model. We hypothesize that TBAs are ineffectively insulated by the TFLL and therefore exhibit higher TER than does that for a well-insulting TFLL-covered tear. As time proceeds, TBAs increase in number and size, thereby increasing the cornea area-averaged TER and decreasing OST. Tear-breakup areas were assessed from image analysis of fluorescein tear-film-breakup video recordings and are included in the heat-transfer description of OST. Model-predicted OSTs agree well with clinical experiments. Percent reductions in TER of lipid-covered tear range from 50 to 95% of that for pure water, in good agreement with literature. The physical picture of noninsulating or ruptured TFLL spots followed by enhanced evaporation from underlying cooler tear-film ruptures is consistent with the evaporative-driven mechanism for local tear rupture. A quantitative analysis is presented of in vivo TER from simultaneous clinical measurement of transient OST and TBA. The new heat-transfer model accounts for increased TER through expanding TBAs. Tear evaporation rate varies strongly across the cornea because lipid is effectively missing over tear-rupture troughs. The result is local faster evaporation compared with nonruptured, thick lipid-covered tear. Evaporative-driven tear-film ruptures deepen to a thickness where fluorescein quenching commences and local

  5. Curiosities of arithmetic gases

    International Nuclear Information System (INIS)

    Bakas, I.; Bowick, M.J.

    1991-01-01

    Statistical mechanical systems with an exponential density of states are considered. The arithmetic analog of parafermions of arbitrary order is constructed and a formula for boson-parafermion equivalence is obtained using properties of the Riemann zeta function. Interactions (nontrivial mixing) among arithmetic gases using the concept of twisted convolutions are also introduced. Examples of exactly solvable models are discussed in detail

  6. Strongly interacting Fermi gases

    Directory of Open Access Journals (Sweden)

    Bakr W.

    2013-08-01

    Full Text Available Strongly interacting gases of ultracold fermions have become an amazingly rich test-bed for many-body theories of fermionic matter. Here we present our recent experiments on these systems. Firstly, we discuss high-precision measurements on the thermodynamics of a strongly interacting Fermi gas across the superfluid transition. The onset of superfluidity is directly observed in the compressibility, the chemical potential, the entropy, and the heat capacity. Our measurements provide benchmarks for current many-body theories on strongly interacting fermions. Secondly, we have studied the evolution of fermion pairing from three to two dimensions in these gases, relating to the physics of layered superconductors. In the presence of p-wave interactions, Fermi gases are predicted to display toplogical superfluidity carrying Majorana edge states. Two possible avenues in this direction are discussed, our creation and direct observation of spin-orbit coupling in Fermi gases and the creation of fermionic molecules of 23Na 40K that will feature strong dipolar interactions in their absolute ground state.

  7. Radiation effects in gases

    International Nuclear Information System (INIS)

    Leonhardt, J.W.

    1985-01-01

    Problems in the studies of radiation effects in gases are discussed. By means of ionization- excitation- and electron-capture yields various applications are characterized: ionization detectors, X-ray detectors, radionuclide battery, and radiation-induced chemical gas-phase reactions. Some new results of basic research in respect to the SO 2 oxidation are discussed. (author)

  8. The greenhouse effect gases

    International Nuclear Information System (INIS)

    2006-06-01

    This road-map proposes by the Group Total aims to inform the public on the greenhouse effect gases. It presents the greenhouses effect as a key component of the climate system, the impacts of the human activity, the foreseeable consequences of global warming, the Kyoto protocol and Total commitment in the domain. (A.L.B.)

  9. Magnetic tearing in plasma focus

    International Nuclear Information System (INIS)

    Sharkawy, W.

    1994-01-01

    A plasma focus device used is Mather type filled with hydrogen gas at pressure between 0.1 and 1 torr. When connected to a large capacitor ≤10 KV a discharge is started with peak current 100 KA. Under the influence of the radial electric field E r , due to the potential between electrodes, and B φ the plasma will drift in the axial direction with velocity cE r /B φ . An induced axial magnetic field B z has been detected which due to sheath velocity. A propagation of magnetosonic wave has been observed with velocity ≅10 3 m sec -1 . Such a wave might be excited when the magnetic pressure is much greater than the plasma kinetic pressure B 2 /8π>nKT. Assuming (MHD) to be stable, Tearing model was driven which generally has smaller growth rates than (MHD) modes. Using the designed theoretical model and the plasma parameters the electron energy dΦ/dt=Ba 2 /τ R was calculated to be 2.22 KeV, which is comparable with that detected from X-ray measurements. (author)

  10. Quantitative analysis of tear film fluorescence and discomfort during tear film instability and thinning.

    Science.gov (United States)

    Begley, Carolyn; Simpson, Trefford; Liu, Haixia; Salvo, Eliza; Wu, Ziwei; Bradley, Arthur; Situ, Ping

    2013-04-12

    The purpose of this study was to test the association between tear film fluorescence changes during tear break-up (TBU) or thinning and the concurrent ocular sensory response. Sixteen subjects kept one eye open as long as possible (MBI), indicated their discomfort level continuously, and rated ocular sensations of irritation, stinging, burning, pricking, and cooling using visual analog scales (VAS). Fluorescence of the tear film was quantified by a pixel-based analysis of the median pixel intensity (PI), TBU, and percentage of dark pixels (DarkPix) over time. A cutoff of 5% TBU was used to divide subjects into either break-up (BU) or minimal break-up (BUmin) groups. Tear film fluorescence decreased (median PI) and the percentage of TBU and DarkPix increased in all trials, with the rate significantly greater in the BU than the BUmin group (Mann-Whitney U test, P film thinning best explains decreasing tear film fluorescence during trials. This was highly correlated with increasing ocular discomfort, suggesting that both tear film thinning and TBU stimulate underlying corneal nerves, although TBU produced more rapid stimulation. Slow increases in tear film hyperosmolarity may cause the gradual increase in discomfort during slow tear film thinning, whereas the sharp increases in discomfort during TBU suggest a more complex stimulus.

  11. Danish translation and validation of the International Skin Tear Advisory Panel Skin Tear Classification System

    DEFF Research Database (Denmark)

    Skiveren, J; Bermark, S; LeBlanc, K

    2015-01-01

    OBJECTIVE: The aim of this study was to translate, validate and establish reliability of the International Skin Tear Classification System in Danish. METHOD: Phase 1 of the project involved the translation of the International Skin Tear Advisory Panel (ISTAP) Skin Tear Classification System......) and social and health-care assistants (non-RN) from both primary health care and a Danish university hospital in Copenhagen. Thirty photographs, with equal representation of the three types of skin tears, were selected to test validity. The photographs chosen were those originally used for internal...... and external validation by the ISTAP group. The subjects were approached in their place of work and invited to participate in the study and to attend an educational session related to skin tears. RESULTS: The Danish translation of the ISTAP classification system was tested on 270 non-wound specialists...

  12. Superior glenoid inclination and rotator cuff tears.

    Science.gov (United States)

    Chalmers, Peter N; Beck, Lindsay; Granger, Erin; Henninger, Heath; Tashjian, Robert Z

    2018-03-23

    The objectives of this study were to determine whether glenoid inclination (1) could be measured accurately on magnetic resonance imaging (MRI) using computed tomography (CT) as a gold standard, (2) could be measured reliably on MRI, and (3) whether it differed between patients with rotator cuff tears and age-matched controls without evidence of rotator cuff tears or glenohumeral osteoarthritis. In this comparative retrospective radiographic study, we measured glenoid inclination on T1 coronal MRI corrected into the plane of the scapula. We determined accuracy by comparison with CT and inter-rater reliability. We compared glenoid inclination between patients with full-thickness rotator cuff tears and patients aged >50 years without evidence of a rotator cuff tear or glenohumeral arthritis. An a priori power analysis determined adequate power to detect a 2° difference in glenoid inclination. (1) In a validation cohort of 37 patients with MRI and CT, the intraclass correlation coefficient was 0.877, with a mean difference of 0° (95% confidence interval, -1° to 1°). (2) For MRI inclination, the inter-rater intraclass correlation coefficient was 0.911. (3) Superior glenoid inclination was 2° higher (range, 1°-4°, P rotator cuff tear group of 192 patients than in the control cohort of 107 patients. Glenoid inclination can be accurately and reliably measured on MRI. Although superior glenoid inclination is statistically greater in those with rotator cuff tears than in patients of similar age without rotator cuff tears or glenohumeral arthritis, the difference is likely below clinical significance. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  13. Energetic approach for ductile tearing

    International Nuclear Information System (INIS)

    Marie, St.

    1999-01-01

    This study focuses on ductile crack initiation and propagation. It aims to propose an approach for the engineer allowing the prediction of the evolution of cracks in large scale components, from parameters determined on laboratory specimens. A crack initiation criterion, defining a J i tenacity related to crack tip blunting proposed in the literature is validated in the study. This criterion is shown to be transferable from laboratory specimens to structures. The literature review shows that an approach based on the dissipated energy in the fracture process during propagation offers an economical and simple solution to simulate large crack growth. A numerical method is proposed to estimate this fracture energy. The existence of an energy parameter G fr is shown, by simulating the propagation by the simultaneous release of several elements and by the use of the Rice integral with an original integration path. This parameter represents the needed energy for a unit crack extension and appears to be intrinsic to the material. A global energy statement allows to relate this parameter to a variation of the plastic part of J integral. It offers a second numerical method to simulate the propagation just from stationary numerical calculations, as well as the elaboration of a simplified method. This approach, using two parameters J i and G fr , intrinsic to the material and experimentally measurable on specimens, is validated on many tests such as crack pipes subjected to four points bending and cracked rings in compression. For example, this approach allows to model up to 90 mm ductile tearing in a pipe with a circumferential through-wall crack in ferritic steel, or to anticipate the evolution of a semi-elliptical crack in an aged austenitic ferritic steel plate subjected to bending. (author)

  14. Process of radioactive waste gases

    International Nuclear Information System (INIS)

    Queiser, H.; Schwarz, H.; Schroter, H.J.

    1975-01-01

    A method is described in which the radiation level of waste gases from nuclear power plants containing both activation and fission gases is controlled at or below limits permitted by applicable standards by passing such gases, prior to release to the atmosphere, through an adsorptive delay path including a body of activated carbon having the relation to the throughput and character of such gases. (U.S.)

  15. Rotator cuff tears: An evidence based approach

    Science.gov (United States)

    Sambandam, Senthil Nathan; Khanna, Vishesh; Gul, Arif; Mounasamy, Varatharaj

    2015-01-01

    Lesions of the rotator cuff (RC) are a common occurrence affecting millions of people across all parts of the globe. RC tears are also rampantly prevalent with an age-dependent increase in numbers. Other associated factors include a history of trauma, limb dominance, contralateral shoulder, smoking-status, hypercholesterolemia, posture and occupational dispositions. The challenge lies in early diagnosis since a high proportion of patients are asymptomatic. Pain and decreasing shoulder power and function should alert the heedful practitioner in recognizing promptly the onset or aggravation of existing RC tears. Partial-thickness tears (PTT) can be bursal-sided or articular-sided tears. Over the course of time, PTT enlarge and propagate into full-thickness tears (FTT) and develop distinct chronic pathological changes due to muscle retraction, fatty infiltration and muscle atrophy. These lead to a reduction in tendon elasticity and viability. Eventually, the glenohumeral joint experiences a series of degenerative alterations - cuff tear arthropathy. To avert this, a vigilant clinician must utilize and corroborate clinical skill and radiological findings to identify tear progression. Modern radio-diagnostic means of ultrasonography and magnetic resonance imaging provide excellent visualization of structural details and are crucial in determining further course of action for these patients. Physical therapy along with activity modifications, anti-inflammatory and analgesic medications form the pillars of nonoperative treatment. Elderly patients with minimal functional demands can be managed conservatively and reassessed at frequent intervals. Regular monitoring helps in isolating patients who require surgical interventions. Early surgery should be considered in younger, active and symptomatic, healthy patients. In addition to being cost-effective, this helps in providing a functional shoulder with a stable cuff. An easily reproducible technique of maximal strength and

  16. A case of recurrent bloody tears

    Directory of Open Access Journals (Sweden)

    Karslıoğlu Ş

    2011-07-01

    Full Text Available Şafak Karslioğlu1, Ilke Bahçeci Şimşek2, Müslime Akbaba11Ìstanbul Oculoplastic and Orbital Surgery and Ocular Oncology Center, 2Ophthalmology Department, Medicine Hospital, Ìstanbul, TurkeyAbstract: Well-known causes of blood-tinged epiphora are conjunctival lesions, tumors of the lacrimal apparatus, and systemic bleeding disorders. We describe an unusual patient who presented with recurrent episodes of bloody tearing which began following an erythema multiforme-like drug eruption. He experienced chronic conjunctivitis which resulted in a few minor symblephara. One year later, the patient developed attacks of bloody tearing. All clinical, radiologic, and laboratory investigations related to bloody epiphora were within normal limits except for a mild, nonspecific chronic inflammatory reaction in the perivascular tissues of the lacrimal gland and orbital soft tissues. Also, an increase in vascular permeability and contrast extravasation on carotid angiography was detected. High-dose vitamin C was administered. The patient continued to have unilateral bloody tears intermittently for two years, but the episodes became much less frequent and had resolved by three years. It is conceivable that increased vascular permeability following the systemic inflammatory process could have played a role in the etiology of recurrent bloody tears in this atypical patient.Keywords: bloody tears, erythema multiforme, drug eruption, vitamin C

  17. Allergy and allergic mediators in tears.

    Science.gov (United States)

    Leonardi, Andrea

    2013-12-01

    The identification of inflammatory mediators in the tear fluid have been extensively used in ocular allergy to find either a 'disease marker', to better understand the immune mechanisms involved in the ocular surface inflammation, or to identify potential targets for therapeutic interventions. While the clinical characteristics allow a relatively convincing diagnosis of ocular allergic diseases, in the initial, non active phases, or in the chronic stages, the diagnosis may not be clear. Although not highly specific, total tear IgE can be measured with local tests by inserting a paper strip in the lower meniscus. The measurement of tear specific inflammatory markers, such as histamine, tryptase, ECP, IL-4, IL-5 and eotaxin, may be useful for the diagnosis or monitoring ocular allergy. New technologies such as multiplex bead assays, membrane-bound antibody array and proteomic techniques can characterize the distribution of a wide range of bioactive trace proteins in tears. Dozens of mediators, cytokines, chemokines, growth factors, angiogenic modulators, enzymes and inhibitors were thus identified in small tear samples using these techniques, providing the possible identification of specific biomarker for either specific disease or disease activity. However, to date, there is no a single specific laboratory test suitable for the diagnosis and monitoring of allergic conjunctivitis. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Fuel gases in Algeria

    International Nuclear Information System (INIS)

    Arachiche, B.; Elandaloussi, H.

    1996-01-01

    For a country like Algeria, fuel gases represent an important economical challenge. To answer the increasing energy demand in the transportation sector, the use of fuel gases allows to preserve the petroleum reserves and to create specific industrial structures devoted to LPG-f (liquefied petroleum gas-fuel) and NGV (natural gas for vehicles). This paper presents the energy policy of Algeria, its reserves, production, and exportations of hydrocarbons and the internal rational use of energy sources according to its economic and environmental policy and to its internal needs. The energy consumption of Algeria in the transportation sector represents 2/3 of the petroleum products consumed in the internal market and follows a rapid increase necessary to the socio-economic development of the country. The Algerian experience in fuel gases is analysed according to the results of two successive experimentation periods for the development of NGV before and after 1994, and the resulting transportation and distribution network is described. The development of LPG-f has followed also an experimental phase for the preparation of regulation texts and a first statement of the vehicles conversion to LPG-f is drawn with its perspectives of development according to future market and prices evolutions. (J.S.)

  19. Plate Tearing Under Mixed Mode Loading

    DEFF Research Database (Denmark)

    Andersen, Rasmus Grau; Nielsen, Kim Lau; Felter, Christian Lotz

    2016-01-01

    the mesh cannot accurately capture the localization process that precedes ductile failure. To fertilize accurate predictions of such sheet tearing, the energy dissipated during localization must, therefore, be accounted for in the cohesive traction-separation law. The fact is that the local thinning...... that takes place in front of an advancing crack can significantly enhance the crack growth resistanceas the energy going into thinning the sheet typically dominates the total fracture energy.This has been investigated in great details for the case of pure Mode I tearing and both the energy dissipation, peak...... stress, and shape of the cohesive traction-separation law have been laid out. In a similar fashion, the present study resolves the sequence of failure details related to steady-state sheet tearing under mixed mode loading by employing the micro-mechanics based Gurson model. But, the fracture process...

  20. Slab tears and intermediate-depth seismicity

    Science.gov (United States)

    Meighan, Hallie E.; ten Brink, Uri S.; Pulliam, Jay

    2013-01-01

    Active tectonic regions where plate boundaries transition from subduction to strike slip can take several forms, such as triple junctions, acute, and obtuse corners. Well-documented slab tears that are associated with high rates of intermediate-depth seismicity are considered here: Gibraltar arc, the southern and northern ends of the Lesser Antilles arc, and the northern end of Tonga trench. Seismicity at each of these locations occurs, at times, in the form of swarms or clusters, and various authors have proposed that each marks an active locus of tear propagation. The swarms and clusters start at the top of the slab below the asthenospheric wedge and extend 30–60 km vertically downward within the slab. We propose that these swarms and clusters are generated by fluid-related embrittlement of mantle rocks. Focal mechanisms of these swarms generally fit the shear motion that is thought to be associated with the tearing process.

  1. Bilateral Giant Retinal Tear and Sequential Vitrectomy.

    Science.gov (United States)

    Mustapha, Mushawiahti; Roufail Franzco, Edward

    2017-01-01

    To describe the excellent outcome of surgery for bilateral giant retinal tears (GRTs) with better options of endotamponade. This is a case report of a 62-year-old man who presented with bilateral GRTs and associated retinal detachment. The tear in the right eye was supero-temporal and silicone oil was used as an endotamponade. The tear in the left eye was infero-temporal and perfluorocarbon liquid was used as an endotamponade. The outcome at 6 months after surgery was excellent with visual acuities of 6/6 in both eyes. Improved availability of endotamponade agents allows repair of bilateral GRTs to be done at the same time, with good surgical outcomes.

  2. Rotator cuff tear measurement by arthropneumotomography

    International Nuclear Information System (INIS)

    Kilcoyne, R.F.; Matsen, F.A. III

    1983-01-01

    Five years of experience with a method of shoulder arthrography using upright tomography in cases of suspected or known rotator cuff tears has demonstrated its effectiveness. The value of the procedure lies in its ability to demonstrate the size of the cuff tear and the thickness of the remaining cuff tissue. This information provides the surgeon with a preoperative estimate of the difficulty of the repair and the prognosis for a good functional recovery. In 33 cases, there was good correlation between the upright thin-section tomogram findings and the surgical results. The tomograms provided better information about the size of the tear and the quality of the remaining cuff than did plain arthrograms

  3. Meniscal Tear Film Fluid Dynamics Near Marx’s Line

    KAUST Repository

    Zubkov, V. S.; Breward, C. J. W.; Gaffney, E. A.

    2013-01-01

    meniscus. However, resolving tear film behaviour within the meniscus and especially its apices is required to characterise the flow dynamics where the tear film is especially thin, and thus most susceptible to evaporatively induced hyperosmolarity

  4. Introduction to the linear theory of tearing instabilities

    International Nuclear Information System (INIS)

    Hazeltine, R.D.

    1978-02-01

    The reasons why tearing instabilities might bear importantly on tokamak performance are considered. The mechanism of tearing is described and the method by which this mechanism is analyzed is outlined. A survey is given of typical growth rate predictions

  5. Superior labrum anterior-to-posterior tear.

    Science.gov (United States)

    Sum, Jonathan C; Omid, Reza

    2012-12-01

    The patient was a 25-year-old male college student with a chief complaint of right shoulder pain. The patient was initially diagnosed with bicipital tendinitis by his physician and had been treated for 4 weeks by a physical therapist. However, his symptoms did not improve and he was unable to return to his preinjury activity levels, so he sought the services of another physical therapist for a second opinion. Due to concern for a labrum tear, the physical therapist referred the patient to an orthopaedic surgeon. Magnetic resonance arthrography revealed findings consistent with a superior labrum anterior-to-posterior tear.

  6. On Classical Ideal Gases

    Directory of Open Access Journals (Sweden)

    Laurent Chusseau

    2013-02-01

    Full Text Available We show that the thermodynamics of ideal gases may be derived solely from the Democritean concept of corpuscles moving in vacuum plus a principle of simplicity, namely that these laws are independent of the laws of motion, aside from the law of energy conservation. Only a single corpuscle in contact with a heat bath submitted to a z and t-invariant force is considered. Most of the end results are known but the method appears to be novel. The mathematics being elementary, the present paper should facilitate the understanding of the ideal gas law and of classical thermodynamics even though not-usually-taught concepts are being introduced.

  7. Tear progression of symptomatic full-thickness and partial-thickness rotator cuff tears as measured by repeated MRI.

    Science.gov (United States)

    Kim, Yang-Soo; Kim, Sung-Eun; Bae, Sung-Ho; Lee, Hyo-Jin; Jee, Won-Hee; Park, Chang Kyun

    2017-07-01

    The purpose of this study was to analyse the natural course of symptomatic full-thickness and partial-thickness rotator cuff tears treated non-operatively and to identify risk factors affecting tear enlargement. One hundred and twenty-two patients who received non-surgical treatment for a partial- or full-thickness supraspinatus tear were included in this study. All rotator cuff tears were diagnosed with magnetic resonance imaging (MRI), and the same modality was used for follow-up studies. Follow-up MRI was performed after at least a 6-month interval. We evaluated the correlation between tear enlargement and follow-up duration. Eleven risk factors were analysed by both univariate and multivariate analyses to identify factors that affect enlargement of rotator cuff tears. The mean follow-up period was 24.4 ± 19.5 months. Out of 122 patients, 34 (27.9%) patients had an initial full-thickness tear and 88 (72.1%) patients had a partial-thickness tear. Considering all patients together, tear size increased in 51/122 (41.8%) patients, was unchanged in 65/122 (53.3%) patients, and decreased in 6/122 (4.9%) patients. Tear size increased for 28/34 (82.4%) patients with full-thickness tears and 23/88 (26.1%) patients with partial-thickness tears. From the two groups which were followed over 12 months, a higher rate of enlargement was observed in full-thickness tears than in partial-thickness tears (6-12 months, n.s.; 12-24 months, P = 0.002; over 24 months, P rotator cuff tears and 23/88 (26.1%) of symptomatic partial-thickness tears increased in size over a follow-up period of 6-100 months. Full-thickness tears showed a higher rate of enlargement than partial-thickness tears regardless of the follow-up duration. Univariate and multivariate analyses suggested that full-thickness tear was the most reliable risk factor for tear enlargement. The clinical relevance of these observations is that full-thickness rotator cuff tears treated conservatively should be

  8. Removing radioactive noble gases from nuclear process off-gases

    International Nuclear Information System (INIS)

    Lofredo, A.

    1977-01-01

    A system is claimed for separating, concentrating and storing radioactive krypton and xenon in the off-gases from a boiling water reactor, wherein adsorption and cryogenic distillation are both efficiently used for rapid and positive separation and removal of the radioactive noble gases, and for limiting such gases in circulation in the system to low inventory at all times, and wherein the system is self-regulating to eliminate operator options or attention

  9. A Controlled Study on the Correlation between Tear Film Volume and Tear Film Stability in Diabetic Patients.

    Science.gov (United States)

    Eissa, Iman M; Khalil, Noha M; El-Gendy, Heba A

    2016-01-01

    Purpose. To assess the tear film quantity and correlate it with the quality and stability of the tear film in diabetics and compare them to age matched controls. Introduction. Diabetes affects tear film parameters in multiple ways. Poor metabolic control and neuropathy are postulated factors. To further understand how diabetes affects tear film parameters this study was conducted. Subjects and Methods. Tear meniscus height was measured by anterior segment OCT, along with tear thinning time, a subtype of noninvasive tear break-up time, and blinking rate per minute which were all recorded for 22 diabetic patients. Correlations between these tear film parameters were studied and then compared to 16 age matched controls. Results. A statistically significant difference was found in blinking rate between the diabetic and the control group (P = 0.002), with higher blinking rate among diabetics. All tear film parameters were negatively correlated with duration of diabetes. A positive correlation was found between tear film volume and stability. Conclusion. Diabetes affects the tear film in various ways. Diabetics should be examined for dry eye signs even in absence of symptoms which may be masked by associated neuropathy. Duration of diabetes has an impact on tear film status.

  10. A Controlled Study on the Correlation between Tear Film Volume and Tear Film Stability in Diabetic Patients

    Directory of Open Access Journals (Sweden)

    Iman M. Eissa

    2016-01-01

    Full Text Available Purpose. To assess the tear film quantity and correlate it with the quality and stability of the tear film in diabetics and compare them to age matched controls. Introduction. Diabetes affects tear film parameters in multiple ways. Poor metabolic control and neuropathy are postulated factors. To further understand how diabetes affects tear film parameters this study was conducted. Subjects and Methods. Tear meniscus height was measured by anterior segment OCT, along with tear thinning time, a subtype of noninvasive tear break-up time, and blinking rate per minute which were all recorded for 22 diabetic patients. Correlations between these tear film parameters were studied and then compared to 16 age matched controls. Results. A statistically significant difference was found in blinking rate between the diabetic and the control group (P=0.002, with higher blinking rate among diabetics. All tear film parameters were negatively correlated with duration of diabetes. A positive correlation was found between tear film volume and stability. Conclusion. Diabetes affects the tear film in various ways. Diabetics should be examined for dry eye signs even in absence of symptoms which may be masked by associated neuropathy. Duration of diabetes has an impact on tear film status.

  11. Quasi-linear evolution of tearing modes

    International Nuclear Information System (INIS)

    Pellat, R.; Frey, M.; Tagger, M.

    1983-07-01

    The growth of a Tearing instability in Rutherford's nonlinear regime is investigated. Using a singular perturbation technique, lowest order Rutherford's result is recovered. To the following order it is shown that the mode generates a quasi-linear deformation of the equilibrium flux profile, whose resistive diffusion slows down the growth and shows the possibility of a saturation of the instability

  12. Simulation of saturated tearing modes in tokamaks

    International Nuclear Information System (INIS)

    Nguyen, Canh N.; Bateman, Glenn; Kritz, Arnold H.

    2004-01-01

    A quasi-linear model, which includes the effect of the neoclassical bootstrap current, is developed for saturated tearing modes in order to compute magnetic island widths in axisymmetric toroidal plasmas with arbitrary aspect ratio and cross-sectional shape. The model is tested in a simple stand-alone code and is implemented in the BALDUR [C. E. Singer et al., Comput. Phys. Commun. 49, 275 (1982)] predictive modeling code. It is found that the widths of tearing mode islands increase with decreasing aspect ratio and with increasing elongation. Also, the island widths increase when the gradient of the current density increases at the edge of the islands and when the current density inside the islands is suppressed, such as the suppression caused by the near absence of the bootstrap current within the islands. In simulations of tokamak discharges, it is found that tearing mode island widths oscillate in time in response to periodic sawtooth crashes. The local enhancements in the transport produced by magnetic islands have a noticeable effect on global plasma confinement in simulations of low aspect ratio, high beta tokamaks, where saturated tearing mode islands can occur with widths that are greater than 15% of the plasma minor radius

  13. Treatment for acute anterior cruciate ligament tear

    DEFF Research Database (Denmark)

    Frobell, Richard B; Roos, Harald P; Roos, Ewa M

    2013-01-01

    To compare, in young active adults with an acute anterior cruciate ligament (ACL) tear, the mid-term (five year) patient reported and radiographic outcomes between those treated with rehabilitation plus early ACL reconstruction and those treated with rehabilitation and optional delayed ACL...

  14. Glenohumeral stability in simulated rotator cuff tears

    NARCIS (Netherlands)

    Steenbrink, F.; Groot, J.H.; Veeger, H.E.J.; Helm, F.C.; Rozing, P.M.

    2009-01-01

    Rotator cuff tears disrupt the force balance in the shoulder and the glenohumeral joint in particular, resulting in compromised arm elevation torques. The trade-off between glenohumeral torque and glenohumeral stability is not yet understood. We hypothesize that compensation of lost abduction torque

  15. Acute compartment syndrome after medial gastrocnemius tear.

    Science.gov (United States)

    Sit, Yan Kit; Lui, Tun Hing

    2015-02-01

    Acute compartment syndrome after medial gastrocnemius tear is very rare. It can involve the superficial posterior compartment alone or progress to involve all the 4 compartments of the lower legs. Those patients with high pain tolerance and minor trauma can lead to delayed presentation. Immediate fasciotomy is the treatment of choice. Therapeutic Level IV, Case Study. © 2014 The Author(s).

  16. Evaporation-driven instability of the precorneal tear film.

    Science.gov (United States)

    Peng, Cheng-Chun; Cerretani, Colin; Braun, Richard J; Radke, C J

    2014-04-01

    Tear-film instability is widely believed to be a signature of eye health. When an interblink is prolonged, randomly distributed ruptures occur in the tear film. "Black spots" and/or "black streaks" appear in 15 to 40 s for normal individuals. For people who suffer from dry eye, tear-film breakup time (BUT) is typically less than a few seconds. To date, however, there is no satisfactory quantitative explanation for the origin of tear rupture. Recently, it was proposed that tear-film breakup is related to locally high evaporative thinning. A spatial variation in the thickness of the tear-film lipid layer (TFLL) may lead to locally elevated evaporation and subsequent tear-film breakup. We examine the local-evaporation-driven tear-film-rupture hypothesis in a one-dimensional (1-D) model for the evolution of a thin aqueous tear film overriding the cornea subject to locally elevated evaporation at its anterior surface and osmotic water influx at its posterior surface. Evaporation rate depends on mass transfer both through the coating lipid layer and through ambient air. We establish that evaporation-driven tear-film breakup can occur under normal conditions but only for higher aqueous evaporation rates. Predicted roles of environmental conditions, such as wind speed and relative humidity, on tear-film stability agree with clinical observations. More importantly, locally elevated evaporation leads to hyperosmolar spots in the tear film and, hence, vulnerability to epithelial irritation. In addition to evaporation rate, tear-film instability depends on the strength of healing flow from the neighboring region outside the breakup region, which is determined by the surface tension at the tear-film surface and by the repulsive thin-film disjoining pressure. This study provides a physically consistent and quantitative explanation for the formation of black streaks and spots in the human tear film during an interblink. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. MR accuracy and arthroscopic incidence of meniscal radial tears

    Energy Technology Data Exchange (ETDEWEB)

    Magee, Thomas; Shapiro, Marc; Williams, David [Department of Radiology, Neuroimaging Institute, 27 East Hibiscus Blvd., Melbourne, FL 32901 (United States)

    2002-12-01

    A meniscal radial tear is a vertical tear that involves the inner meniscal margin. The tear is most frequent in the middle third of the lateral meniscus and may extend outward in any direction. We report (1) the arthroscopic incidence of radial tears, (2) MR signs that aid in the detection of radial tears and (3) our prospective accuracy in detection of radial tears. Design and patients. Three musculoskeletal radiologists prospectively read 200 consecutive MR examinations of the knee that went on to arthroscopy by one orthopedic surgeon. MR images were assessed for location and MR characteristics of radial tears. MR criteria used for diagnosis of a radial tear were those outlined by Tuckman et al.: truncation, abnormal morphology and/or lack of continuity or absence of the meniscus on one or more MR images. An additional criterion used was abnormal increased signal in that area on fat-saturated proton density or T2-weighted coronal and sagittal images. Prospective MR readings were correlated with the arthroscopic findings.Results. Of the 200 consecutive knee arthroscopies, 28 patients had radial tears reported arthroscopically (14% incidence). MR readings prospectively demonstrated 19 of the 28 radial tears (68% sensitivity) when the criteria for diagnosis of a radial tear were truncation or abnormal morphology of the meniscus. With the use of the additional criterion of increased signal in the area of abnormal morphology on fat-saturated T2-weighted or proton density weighted sequences, the prospective sensitivity was 25 of 28 radial tears (89% sensitivity). There were no radial tears described in MR reports that were not demonstrated on arthroscopy (i.e., there were no false positive MR readings of radial tears in these 200 patients). Radial tears are commonly seen at arthroscopy. There was a 14% incidence in this series of 200 patients who underwent arthroscopy. Prospective detection of radial tears was 68% as compared with arthroscopy when the criteria as

  18. MR accuracy and arthroscopic incidence of meniscal radial tears

    International Nuclear Information System (INIS)

    Magee, Thomas; Shapiro, Marc; Williams, David

    2002-01-01

    A meniscal radial tear is a vertical tear that involves the inner meniscal margin. The tear is most frequent in the middle third of the lateral meniscus and may extend outward in any direction. We report (1) the arthroscopic incidence of radial tears, (2) MR signs that aid in the detection of radial tears and (3) our prospective accuracy in detection of radial tears. Design and patients. Three musculoskeletal radiologists prospectively read 200 consecutive MR examinations of the knee that went on to arthroscopy by one orthopedic surgeon. MR images were assessed for location and MR characteristics of radial tears. MR criteria used for diagnosis of a radial tear were those outlined by Tuckman et al.: truncation, abnormal morphology and/or lack of continuity or absence of the meniscus on one or more MR images. An additional criterion used was abnormal increased signal in that area on fat-saturated proton density or T2-weighted coronal and sagittal images. Prospective MR readings were correlated with the arthroscopic findings.Results. Of the 200 consecutive knee arthroscopies, 28 patients had radial tears reported arthroscopically (14% incidence). MR readings prospectively demonstrated 19 of the 28 radial tears (68% sensitivity) when the criteria for diagnosis of a radial tear were truncation or abnormal morphology of the meniscus. With the use of the additional criterion of increased signal in the area of abnormal morphology on fat-saturated T2-weighted or proton density weighted sequences, the prospective sensitivity was 25 of 28 radial tears (89% sensitivity). There were no radial tears described in MR reports that were not demonstrated on arthroscopy (i.e., there were no false positive MR readings of radial tears in these 200 patients). Radial tears are commonly seen at arthroscopy. There was a 14% incidence in this series of 200 patients who underwent arthroscopy. Prospective detection of radial tears was 68% as compared with arthroscopy when the criteria as

  19. The Tear Osmolarity Changes After Cataract Surgery

    Directory of Open Access Journals (Sweden)

    Banu Öncel

    2012-01-01

    Full Text Available Pur po se: To determine the tear osmolarity changes in patients who had undergone phacoemulsification surgery. Ma te ri al and Met hod: Tear osmolarity measurements were performed in 30 eyes of 30 patients who had undergone cataract surgery without any complication. Measurements were performed before surgery and consecutively at 1st month, 3rd month, and 6th month after the surgery. TearLab osmometer (TearLab Corporation, San Diego, CA, USA device was used for the measurements and paired ttest was used for statistical analysis. Re sults: The mean age of the patients was 72.3±3.7 (67-78 years. Thirteen patients were men and 17 patients were women. The mean osmolarity values were 305.8±6.5 mOsm/L before the surgery and 312.3±6.4 mOsm/L at 1st month, 307.5±5.1 mOsm/L at 3rd month and 305.1±5.7 at 6th month after the surgery. The difference between the values before surgery and at 1st month was found statistically significant (p=0.001. Dis cus si on: The tear osmolarity increases at the first month after surgery but decreases to the levels measured before surgery at the 3rd month. The increase at the first month may be due to the corneal incisions and medication used after the surgery. We think that we have to take into account this similarity increase in all cataract patients, especially in those who also have dry eye disease. (Turk J Ophthalmol 2012; 42: 35-7

  20. Posterior horn lateral meniscal tears simulating meniscofemoral ligament attachment in the setting of ACL tear: MRI findings

    International Nuclear Information System (INIS)

    Park, Lawrence S.; Jacobson, Jon A.; Jamadar, David A.; Caoili, Elaine; Kalume-Brigido, Monica; Wojtys, Edward

    2007-01-01

    We have noted apparent far lateral meniscal attachment of the meniscofemoral ligament (MFL) with an anterior cruciate ligament (ACL) tear. This study evaluates MFL attachment and association with posterior horn lateral meniscus (PHLM) tear. Nine months of knee arthroscopy reports were reviewed to classify the PHLM and ACL as torn or normal. After excluding those with prior knee surgery, MR images were reviewed by two radiologists to determine the number of images lateral to PCL, which showed the ligaments of Humphrey and Wrisberg visible as structures separate from the PHLM. Any patient with abnormal PHLM surface signal not continuous with the MFL was excluded. MRI findings were compared with arthroscopy using Student's t test and Fisher's exact test. Of the 54 participants, 5 had PHLM tears and 49 were normal. Twenty-one had ACL tears; all those with an PHLM tear had an ACL tear. The ligament of Humphrey inserted on average 0.9 consecutive images lateral to the PCL without an PHLM tear and 4.7 with an PHLM tear; the ligament of Wrisberg inserted on average 3.0 consecutive images without an PHLM tear and 4.5 with an PHLM tear (slice thickness/gap = 3 mm/0.5 mm). There was a significant association between PHLM tear and number of images (p = 0.0028), and between ACL tear and this type of PHLM tear (p = 0.0064). Apparent far lateral meniscal extension of a meniscofemoral ligament (greater than or equal to four images lateral to the PCL) should be considered as a possible PHLM tear, especially in the setting of an ACL tear. (orig.)

  1. [Alterations in tears aqueous layer during cytostatics treatment].

    Science.gov (United States)

    Wojciechowska, Katarzyna; Wieckowska-Szakiel, Marzena; Rózalska, Barbara; Jurowski, Piotr

    2013-01-01

    The aim of the study was to evaluate tears secretion, pH and lysozyme activity in tears aqueous layer during chemotherapy in lung, breast and bowel cancer. 36 patients were enrolled to the study. Depending on the type of cancer and type of chemotherapy patients were divided into three groups. Group I (12 patients) diagnosed with non-small-cell lung cancer treated with PE schema (cisplatin, etoposide), Group II (12 patients) with breast cancer treated with FAC schema (fluorouracil, doxorubicin, cyclophosphamide), Group III (12 patients) with bowel cancer treated with FU/LV schema (fluorouracil, leucovorin). In all the patients: Schirmer's I test, pH measurements and lysozyme test were performed. Patients were examined before chemotherapy, after 2nd, 4th, 6th cycle. In group I and II lowering of tears secretion (p tears secretion (p tears film in all groups (p tears aqueous layer causing alterations of tears secretions. PH alterations depending on type of chemotherapy was observed. Lowering of lysozyme activity in tears was observed. All the deteriorations aggravate with duration of chemotherapy. Alterations of tears film parameters during chemotherapy may influence upon eye surface homeostasis and infectious complication. tears aqueous layer, Schirmer's test, lysozyme activity, tears pH.

  2. Magnetic resonance imaging of meniscal bucket-handle tears

    International Nuclear Information System (INIS)

    Dfouni, N.; Garcia, J.; Kindynis, Ph.; Bosson, D.

    1997-01-01

    To define MR signs of meniscal bucket-handle tears and evaluate the diagnostic efficiency of this technique. Retrospective study of 30 patients with a meniscal bucket-handle tear and 30 with a different type of tear, all proven by arthroscopy. The following MR signs of a bucket-handle tear were evaluated: 'separate meniscal fragment, 'double posterior cruciate ligament', 'snake sign' and 'double anterior horn'. A correct diagnosis of a bucket-handle tear was only made in 18/30 of patients. Several of the MR signs were seen in the same patient in 17 cases. A double posterior cruciate ligament was present only in cases of medial meniscus tears. The 12 menisci without these signs, and therefore not diagnosed as bucket-handle tears, were all classified as meniscal tears on the basis of signal extending to the meniscal surface. Nine of these were not displaced into the inter-condylar notch at arthroscopy. The interobserver agreement was excellent: kappa 0.88. The diagnosis of a bucket-handle meniscal tear, if it is displaced, can be made when one or more of the four MR evaluated signs are present. Other forms of meniscal tears are only exceptionally diagnosed as bucket-handle tears. (authors)

  3. MR imaging-based diagnosis and classification of meniscal tears.

    Science.gov (United States)

    Nguyen, Jie C; De Smet, Arthur A; Graf, Ben K; Rosas, Humberto G

    2014-01-01

    Magnetic resonance (MR) imaging is currently the modality of choice for detecting meniscal injuries and planning subsequent treatment. A thorough understanding of the imaging protocols, normal meniscal anatomy, surrounding anatomic structures, and anatomic variants and pitfalls is critical to ensure diagnostic accuracy and prevent unnecessary surgery. High-spatial-resolution imaging of the meniscus can be performed using fast spin-echo and three-dimensional MR imaging sequences. Normal anatomic structures that can mimic a tear include the meniscal ligament, meniscofemoral ligaments, popliteomeniscal fascicles, and meniscomeniscal ligament. Anatomic variants and pitfalls that can mimic a tear include discoid meniscus, meniscal flounce, a meniscal ossicle, and chondrocalcinosis. When a meniscal tear is identified, accurate description and classification of the tear pattern can guide the referring clinician in patient education and surgical planning. For example, longitudinal tears are often amenable to repair, whereas horizontal and radial tears may require partial meniscectomy. Tear patterns include horizontal, longitudinal, radial, root, complex, displaced, and bucket-handle tears. Occasionally, meniscal tears can be difficult to detect at imaging; however, secondary indirect signs, such as a parameniscal cyst, meniscal extrusion, or linear subchondral bone marrow edema, should increase the radiologist's suspicion for an underlying tear. Awareness of common diagnostic errors can ensure accurate diagnosis of meniscal tears. Online supplemental material is available for this article. ©RSNA, 2014.

  4. Selective noble gases monitoring

    International Nuclear Information System (INIS)

    Janecka, S.; Jancik, O.; Kapisovsky, V.; Kubik, I.; Sevecka, S.

    1995-01-01

    The monitoring of leak releases from ventilation stack of NPP requires a system by several orders more sensitive then currently used radiometer Kalina, designed to cover the range up to a design-based accident. To reach this goal a noble gases monitor with a germanium detector (MPVG) has been developed. It enables nuclide selective monitoring of current value of volume activity of particular nuclides in ventilation stack and daily releases of noble gases (balancing). MPVG can be viewed as a system build of three levels of subsystem: measuring level; control level; presentation level. Measuring level consists of gamma-spectroscopy system and operational parameters monitoring unit (flow rate, temperature, humidity). Control level provides communication between presentation and measuring level, acquisition of operational parameters and power supply. The presentation level of MPVG enables: 1) the measured data storage in predetermined time intervals; 2) the presentation of measured and evaluated values of radiation characteristics. The monitored radionuclides - default set: argon-41, krypton-85m, krypton-87, krypton-88, krypton-89, xenon-131m, xenon-133, xenon-133m, xenon-135, xenon-135m, xenon-137 and xenon-138. The values of volume activities observed at maximum releases have been approximately ten times higher. In that case in balancing some other nuclides exceed corresponding detection limits: 88 Kr(67; 22) Bq/m 3 ; 85m Kr(17; 7) Bq/m 3 ; 135m Xe(7.1; 0.5) Bq/m 3 ; 138 Xe(5.9; 0.9) Bq/m 3 . (J.K.)

  5. Selective noble gases monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Janecka, S; Jancik, O; Kapisovsky, V; Kubik, I; Sevecka, S [Nuclear Power Plants Research Institute, a.s., Trnava (Slovakia)

    1996-12-31

    The monitoring of leak releases from ventilation stack of NPP requires a system by several orders more sensitive then currently used radiometer Kalina, designed to cover the range up to a design-based accident. To reach this goal a noble gases monitor with a germanium detector (MPVG) has been developed. It enables nuclide selective monitoring of current value of volume activity of particular nuclides in ventilation stack and daily releases of noble gases (balancing). MPVG can be viewed as a system build of three levels of subsystem: measuring level; control level; presentation level. Measuring level consists of gamma-spectroscopy system and operational parameters monitoring unit (flow rate, temperature, humidity). Control level provides communication between presentation and measuring level, acquisition of operational parameters and power supply. The presentation level of MPVG enables: 1) the measured data storage in predetermined time intervals; 2) the presentation of measured and evaluated values of radiation characteristics. The monitored radionuclides - default set: argon-41, krypton-85m, krypton-87, krypton-88, krypton-89, xenon-131m, xenon-133, xenon-133m, xenon-135, xenon-135m, xenon-137 and xenon-138. The values of volume activities observed at maximum releases have been approximately ten times higher. In that case in balancing some other nuclides exceed corresponding detection limits: {sup 88}Kr(67; 22) Bq/m{sup 3}; {sup 85m}Kr(17; 7) Bq/m{sup 3}; {sup 135m}Xe(7.1; 0.5) Bq/m{sup 3}; {sup 138}Xe(5.9; 0.9) Bq/m{sup 3}. (J.K.).

  6. Antioxidant content and ultraviolet absorption characteristics of human tears.

    Science.gov (United States)

    Choy, Camus Kar Man; Cho, Pauline; Benzie, Iris F F

    2011-04-01

    Dry eye syndrome is a common age-related disorder, and decreased antioxidant/ultraviolet (UV) radiation protection in tears may be part of the cause. This study aimed to compare the tear antioxidant content and flow rate in young and older adults. The total antioxidant content and UV absorbing properties of various commercially available ophthalmic solutions used to alleviate dry eye symptoms were also examined. Minimally stimulated tears were collected from 120 healthy Chinese adults with no ocular pathology. Two age groups were studied: 19 to 29 years (n = 58) and 50 to 75 years (n = 62). Tear samples from each subject and 13 ophthalmic solutions were analyzed for total antioxidant content (as the Ferric Reducing/Antioxidant Power value). Tear flow rates were estimated from time taken to collect a fixed volume of tear fluid. UV absorbance spectra of pooled fresh reflex tear fluid and the ophthalmic solutions were determined. Results showed that the antioxidant content of minimally stimulated tears from older subjects (398 ± 160 μmol/l) was not significantly lower than that of younger subjects (348 ± 159 μmol/l; p = 0.0915). However, there was a significant difference in the tear flow rates between the two groups (p tears. The effect of low flow rate on the dynamic antioxidant supply to the corneal surface indicates that older subjects have poorer overall defense against photooxidative and other oxidative processes. This could predispose older persons to corneal stress and development of dry eye syndrome. The commercially available artificial tears tested lack both the antioxidant content and UV absorbing characteristics of natural tears. Artificial tears formulations that help restore natural antioxidant and UV absorbing properties to the tear film of the aging eye may help prevent or improve dry eye symptoms and promote ocular health.

  7. Tear dysfunction and the cornea: LXVIII Edward Jackson Memorial Lecture.

    Science.gov (United States)

    Pflugfelder, Stephen C

    2011-12-01

    To describe the cause and consequence of tear dysfunction-related corneal disease. Perspective on effects of tear dysfunction on the cornea. Evidence is presented on the effects of tear dysfunction on corneal morphology, function, and health, as well as efficacy of therapies for tear dysfunction-related corneal disease. Tear dysfunction is a prevalent eye disease and the most frequent cause for superficial corneal epithelial disease that results in corneal barrier disruption, an irregular optical surface, light scattering, optical aberrations, and exposure and sensitization of pain-sensing nerve endings (nociceptors). Tear dysfunction-related corneal disease causes irritation and visual symptoms such as photophobia and blurred and fluctuating vision that may decrease quality of life. Dysfunction of 1 or more components of the lacrimal functional unit results in changes in tear composition, including elevated osmolarity and increased concentrations of matrix metalloproteinases, inflammatory cytokines, and chemokines. These tear compositional changes promote disruption of tight junctions, alter differentiation, and accelerate death of corneal epithelial cells. Corneal epithelial disease resulting from tear dysfunction causes eye irritation and decreases visual function. Clinical and basic research has improved understanding of the pathogenesis of tear dysfunction-related corneal epithelial disease, as well as treatment outcomes. Copyright © 2011 Elsevier Inc. All rights reserved.

  8. Evaluating tear clearance rate with optical coherence tomography.

    Science.gov (United States)

    Garaszczuk, Izabela K; Mousavi, Maryam; Cervino Exposito, Alejandro; Bartuzel, Maciej M; Montes-Micó, Robert; Iskander, D Robert

    2018-02-01

    To assess the early-phase of tear clearance rate (TCR) with anterior segment optical coherence tomography (OCT) and to determine the association between TCR and other clinical measures of the tear film in a group of young subjects with different levels of tear film quality. TCR was classified as the percentage decrease of subject's inferior tear meniscus height 30s after instillation of 5μl 0.9% saline solution. Fifty subjects (32F and 18M) aged (mean±standard deviation) 25.5±4.3 years volunteered for the study. It consisted of a review of medical history, Ocular Surface Disease Index (OSDI) questionnaire, tear film osmolarity measurements, slit lamp examination and TCR estimation based on dynamic measurements of the lower tear meniscus with OCT. Estimates of TCR were contrasted against subject age and tear film measures commonly used for dry eye diagnosis, which includes OSDI score, fluorescein tear film break-up time (FBUT), tear meniscus height (TMH), blinking frequency, tear film osmolarity and corneal staining. The group mean TCR was 29±13% and 36±19% respectively after 30 and 60s margin after saline solution instillation. Statistically significant correlations were found between TCR and FBUT (r 2 =0.319, placrimal functional unit. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  9. Treatment of the subject of tearing instability

    International Nuclear Information System (INIS)

    Paris, P.C.

    1977-07-01

    A simple approach is taken to the mechanics of potential instability associated with the steady tearing portion of J-Integral R-curves. The analysis is developed from simple examples of structural component (or test specimen) configurations with cracks, examining their instability possibilities individually, in order to draw more general conclusions about elastic-plastic cracking instability as contrasted to linear-elastic behavior. Finally, an attempt is made to model a more local cleavage-like instability for material in the fracture process zone just ahead of a crack tip. Results are then presented of a testing program which clearly demonstrates the appropriateness of the tearing instability analysis and which illustrates its broad potential for future application, as well as presenting guidelines for its further development. The material selected for analysis was Ni-Cr-Mo-V rotor steel

  10. Saturated tearing modes in tokamaks with divertors

    International Nuclear Information System (INIS)

    Bateman, G.

    1982-12-01

    We have developed a self-consistent theory of saturated tearing modes capable of predicting multiple magnetic island widths in tokamaks with no assumptions on the cross-sectional shape, aspect ratio, or plasma pressure. We are in the process of implementing this algorithm in the form of a computer code. We propose: (1) to complete, refine, document and publish this computer code; (2) to carry out a survey in which we vary the current profile, aspect ratio, cross-sectional shape, and pressure profile in order to determine their effect on saturated tearing mode magnetic island widths; and (3) to determine the effect of some externally applied magnetic perturbation harmonics on these magnetic island widths. Particular attention will be paid to the coupling between different helical harmonics, the effect of multiple magnetic islands on the profiles of temperature, pressure and current, and the potential of magnetic island overlap leading to a disruptive instability

  11. Stability of tearing modes in tokamak plasmas

    International Nuclear Information System (INIS)

    Hegna, C.C.; Callen, J.D.

    1994-02-01

    The stability properties of m ≥ 2 tearing instabilities in tokamak plasmas are analyzed. A boundary layer theory is used to find asymptotic solutions to the ideal external kink equation which are used to obtain a simple analytic expression for the tearing instability parameter Δ'. This calculation generalizes previous work on this topic by considering more general toroidal equilibria (however, toroidal coupling effects are ignored). Constructions of Δ' are obtained for plasmas with finite beta and for islands that have nonzero width. A simple heuristic estimate is given for the value of the saturated island width when the instability criterion is violated. A connection is made between the calculation of the asymptotic matching parameter in the finite beta and island width case to the nonlinear analog of the Glasser effect

  12. Geometrical influences on neoclassical magnetohydrodynamic tearing modes

    International Nuclear Information System (INIS)

    Kruger, S.E.; Hegna, C.C.; Callen, J.D.

    1997-07-01

    The influence of geometry on the pressure drives of nonideal magnetohydrodynamic tearing modes is presented. In order to study the effects of elongation, triangularity, and aspect ratio, three different machines are considered to provide a range of tokamak configurations: TFTR (circular), DIII-D (D-shaped), and Pegasus (extremely low aspect ratio). For large aspect ratio tokamaks, shaping does very little to influence the pressure gradient drives, while at low aspect ratios, a very strong sensitivity to the profiles is found. In particular, this sensitivity is connected to the strong dependence on the magnetic shear. This suggests that at low aspect ratio it may be possible to stabilize neoclassical tearing modes by flattening the q profile near low order rational surfaces (e.g., q = 2/1) using a combination of shaping and localized current drive, whereas at large aspect ratio it is more difficult

  13. Influence of preoperative artificial tears on tear film after phacoemulsification on dry eye of diabetes patients

    Directory of Open Access Journals (Sweden)

    Rui Su

    2015-05-01

    Full Text Available AIM: To discuss the artificial tears on the tear film of diabetic patients with dry eye preoperatively, and the influence on the tear film's fuctional after phacoemulsification.METHODS: Fifty-four diabetic patients with dry eye(60 eyeswere followed up before phacoemulsification. Preoperatively, group A(30 eyes in 28 caseswas treated with Hydroxyl Indican eye drops and group B(30 eyes in 26 caseswas not treated. Postoperatively, both group A and B were treated with Tobramycin Dexamethasone eye drops, Oprah Winfrey Ibuprofen eye drops and Hydroxyl Indican eye drops. Dry eye symptoms, break up time(BUT, Schirmer Ⅰ test(S Ⅰ t, fluorescein stain test(FIwere measured at 3d preoperatively, and 1, 7, 30, 90d postoperatively.RESULTS: At 3d preoperatively, there was no statistical differences between the two groups for dry eye symptoms, BUT, SⅠt, FI(P>0.05. At 1 and 7d postoperatively, there were significant statistical differents between the two groups for dry eye symptoms(PPP>0.05.CONCLUSION: Using artificial tears before phacoemulsification can improve symptoms of the diabetic patients with dry eye and accelerate the recovery of the tear film.

  14. Artificial tears potpourri: a literature review

    OpenAIRE

    Moshirfar, Majid; Pierson, Kasey; Hanamaikai, Kamalani; Santiago-Caban, Luis; Muthappan, Valliammai; Passi, Samuel F

    2014-01-01

    Majid Moshirfar,1 Kasey Pierson,2,* Kamalani Hanamaikai,3,* Luis Santiago-Caban,1 Valliammai Muthappan,1 Samuel F Passi11Department of Ophthalmology, John A Moran Eye Center, University of Utah, Salt Lake City, UT, USA; 2University of Arizona College of Medicine, Phoenix, Phoenix, AZ, USA; 3A T Still University, School of Osteopathic Medicine in Arizona, Mesa, AZ, USA *These authors contributed equally to this work Abstract: Numerous brands and types of artificial tears are available on the...

  15. Nonlinear growth of strongly unstable tearing modes

    International Nuclear Information System (INIS)

    Waelbroeck, F.L.

    1993-11-01

    Rutherford's theory of the tearing instability is extended to cases where current nonlinearities are important, such as long wavelength modes in current slabs and the m = 1 instability in tokamaks with moderately large aspect-ratios. Of particular interest is the possibility that the associated magnetic islands, as a result of secondary instabilities, have a singular response to the Ohmic diffusion of the current. A family of islands is used to test this possibility; it is found that the response remains bounded

  16. Magnetic resonance imaging of muscle tears

    International Nuclear Information System (INIS)

    De Smet, A.A.; Fisher, D.R.; Heiner, J.P.; Keene, J.S.

    1990-01-01

    Magnetic resonance scans were obtained on 17 patients with acute, subacute, or chronic muscle tears. These patients presented with complaints of persistent pain or a palpable mass. Magnetic resonance findings were characterized according to alterations in muscle shape and the presence of abnormal high signal within the injured muscle. These areas of high signal were noted on both T1-weighted and T2-weighted scans and were presumed to represent areas of intramuscular hemorrhage. (orig.)

  17. Small-scale tearing mode in tokamaks

    International Nuclear Information System (INIS)

    Ivanov, N.V.

    1983-01-01

    Considerations are given on the possible effect of small-scale tearing mode with m >> 1 on the plasma electron thermal conductivity in a tokamak. The estimate of the electron thermal conductivity coefficient is obtained. Calculation results are compared with experimental data. The calculated dependence of radial distribution of electron temperature is shown to vary weakly with the tn(m 2 /m 1 ) alteration everywhere, except for the vicinity of point r approximately 0

  18. Assessment of tear film osmolarity using the TearLab™ osmometer in normal dogs and dogs with keratoconjunctivitis sicca.

    Science.gov (United States)

    Sebbag, Lionel; Park, Shin Ae; Kass, Philip H; Maggs, David J; Attar, Mayssa; Murphy, Christopher J

    2017-07-01

    To evaluate repeatability and reproducibility of tear osmolarity measured using the TearLab ™ osmometer in normal dogs and to assess its diagnostic potential in dogs with keratoconjunctivitis sicca (KCS). Beagle dogs; six normal and five with KCS. Tear osmolarity and Schirmer tear test-1 (STT-1) values were obtained at various times. Normal dogs were assessed for diurnal variation and repeatability and reproducibility of measurements. Dogs with KCS were evaluated before and after 5 months' topical twice-daily therapy with 2% cyclosporine. Mean ± SD tear osmolarity (mOsm/L) was significantly higher in normal dogs (337.4 ± 16.2) than in dogs with KCS before therapy (306.2 ± 18.0; P dogs, tear osmolarity readings were stable during the daytime (P = 0.99). Repeated measurements revealed high variability and typically poor-to-moderate repeatability and reproducibility, although this was improved by taking three successive measurements at each session. Considering combined data from all dogs, a positive correlation existed between STT-1 and tear osmolarity measurements (Pearson's correlation test, P = 0.04, r = 0.62). Canine tear osmolarity as determined by TearLab ™ osmometer was variable, required multiple readings to be informative, and differed from values reported for humans. Dogs with KCS had a lower tear osmolarity than did normal dogs, and this increased following cyclosporine therapy. © 2016 American College of Veterinary Ophthalmologists.

  19. Canonical partition functions: ideal quantum gases, interacting classical gases, and interacting quantum gases

    Science.gov (United States)

    Zhou, Chi-Chun; Dai, Wu-Sheng

    2018-02-01

    In statistical mechanics, for a system with a fixed number of particles, e.g. a finite-size system, strictly speaking, the thermodynamic quantity needs to be calculated in the canonical ensemble. Nevertheless, the calculation of the canonical partition function is difficult. In this paper, based on the mathematical theory of the symmetric function, we suggest a method for the calculation of the canonical partition function of ideal quantum gases, including ideal Bose, Fermi, and Gentile gases. Moreover, we express the canonical partition functions of interacting classical and quantum gases given by the classical and quantum cluster expansion methods in terms of the Bell polynomial in mathematics. The virial coefficients of ideal Bose, Fermi, and Gentile gases are calculated from the exact canonical partition function. The virial coefficients of interacting classical and quantum gases are calculated from the canonical partition function by using the expansion of the Bell polynomial, rather than calculated from the grand canonical potential.

  20. Tearing modes with pressure gradient effect in pair plasmas

    International Nuclear Information System (INIS)

    Cai Huishan; Li Ding; Zheng Jian

    2009-01-01

    The general dispersion relation of tearing mode with pressure gradient effect in pair plasmas is derived analytically. If the pressure gradients of positron and electron are not identical in pair plasmas, the pressure gradient has significant influence at tearing mode in both collisionless and collisional regimes. In collisionless regime, the effects of pressure gradient depend on its magnitude. For small pressure gradient, the growth rate of tearing mode is enhanced by pressure gradient. For large pressure gradient, the growth rate is reduced by pressure gradient. The tearing mode can even be stabilized if pressure gradient is large enough. In collisional regime, the growth rate of tearing mode is reduced by the pressure gradient. While the positron and electron have equal pressure gradient, tearing mode is not affected by pressure gradient in pair plasmas.

  1. Age-related changes in the signal value of tears.

    Science.gov (United States)

    Zeifman, Debra M; Brown, Sarah A

    2011-08-12

    Emotional tears may be uniquely human and are an effective signal of distress in adults. The present study explored whether tears signal distress in younger criers and whether the effect of tears on observers is similar in magnitude across the life span. Participants rated photographs of crying infants, young children, and adults, with tears digitally removed or added. The effectiveness of tears in conveying sadness and eliciting sympathy was greatest for images of adults, intermediate for images of children, and least potent for images of infants. These findings suggest that the signal value of tears varies with the age of the crier. The results may shed light on the functional significance of crying at different stages of human development.

  2. Meniscus tears of the knee: Postarthrogram high resolution CT

    International Nuclear Information System (INIS)

    Kim, Jae Hyoung; Do, Young Soo; You, Jin Jong; Gong, Jae Chul; Kim, Hyung Jin; Chung, Sung Hoon

    1990-01-01

    Thirty-eight knees with clinically suspected meniscal tears were examined with high resolution computed tomography(HRCT) immediately following double contrast arthrography. All subsequently underwent arthroscopy. The findings of postarthrogram HRCT and arthroscopy were compared to evaluated the usefulness of postarthrogram HRCT in diagnosis of the meniscal tears. The sensitivity, specificity and accuracy of HRCT were 96.2%. 83.3% and 92.1% respectively. The anatomic details of the meniscal tears were clearly visible on the HRCT scans. Sagittal and coronal reformation views well visualized the horizontal tears and the relationship of torn meniscal fragments, and well differential the peripheral tears from the synovial recess. Our result indicate that postarthrogram HRCT not only is a sensitive and effective method for the detection and characterization of the meniscal tears, but also provides arthroscopists with the appropriate surgical plans

  3. Magnetic resonance imaging in acute and chronic rotator cuff tears

    International Nuclear Information System (INIS)

    Buirski, G.

    1990-01-01

    Magnetic resonance imaging has been assessed in patients with acute rotator cuff tears and normal radiographs (9 cases) and those with chronic tears and changes of cuff arthropathy (9 cases). All images were obtained using a low field strength system (FONAR 0.3 T). Particular attention was placed on the appearances of the tendon and the cuff muscles themselves. Six complete acute tears were clearly identified, but MRI failed to demonstrate two partial tears. Muscle bulk was preserved in all patients in this group. In contrast, all patients with cuff arthropathy had complete tears of the supraspinatus tendon with marked tendon retraction and associated muscle atrophy: These changes precluded primary surgical repair. MRI should be used to assess muscle atrophy preoperatively in those patients with acute tears. When plain radiographs demonstrate cuff arthropathy, the MRI appearances are predictable and primary repair is unlikely to be successful. Further imaging is therefore not indicated. (orig.)

  4. Economic Hazardous Gases Management for SOX Removal from Flue Gases

    International Nuclear Information System (INIS)

    Isaack, S.L.; Mohi, M.A.; Mohamed, S.T.

    1995-01-01

    Hazardous gases emerging from industries accumulate as pollutants in air and falls as acid rains resulting also in water and soil pollution. To minimize environmental pollution, the present process is suggested in order to desulfurize flue gases resulting from burning fuel oil in a 100/MWh steam power plant. The process makes use of the cheap Ca C O 3 powder as the alkaline material to sequistre the sulphur oxide gases. The resulting sulphur compounds, namely calcium sulphate and gypsum have a great market demand as reducing and sulphiting agents in paper industry and as an important building material. About 44000 ton of gypsum could be produced yearly when treating flue gases resulting from a 100 MWh unit burning fuel oil. Feasibility study shows that a great return on investment could be achieved when applying the process. 1 fig

  5. Anterior Segment Optical Coherence Tomography for Tear Meniscus Evaluation and its Correlation with other Tear Variables in Healthy Individuals

    Science.gov (United States)

    Dhasmana, Renu; Nagpal, Ramesh Chander

    2016-01-01

    Introduction Dry eye is one of the most common ocular diseases in this cyber era. Despite availability of multiple tests, no single test is accurate for the diagnosis of dry eye. Anterior segment optical coherence tomography is the recent tool which can be added in the armentarium of dry eye tests. Aim To evaluate tear meniscus with anterior segment optical coherence tomography and its correlation with other tear variables in normal healthy individuals. Materials and Methods In this prospective cross-sectional observational study, right eye of 203 consecutive patients were studied. All the patients were divided into three groups Group 1, 2 and 3 according to their age ≤20 years, 21-40 years and >40 years respectively. All patients underwent routine ophthalmologic examinations along with slit-lamp bio-microscopy for tear meniscus height measurement, tear film break up time, Schirmer’s I test (with anaesthesia) and optical coherence tomography imaging of inferior tear meniscus height. After focusing of the instrument with a Cross Line (CL) centered on lower tear meniscus at 6’0 clock of cornea, a 6 mm long scan was obtained. The tear meniscus height (μm) and tear meniscus area (mm2) were measured manually with help of callipers by joining upper corneo-meniscus junction to the lower lid-meniscus junction and tear meniscus height and area within the plotted line respectively and calculated by using the integrated analysis available in the custom software. Results There was significant decrease in the all tear variables with the increase in the age. According to age groups in group 1, the mean Schirmer’s (24.0±4.9)mm, tear film break up time (11.1±1.9) sec, tear meniscus height on slit lamp (600.2±167.3)mm were higher but decreased in group 2 (21.5±5.4,10.8±1.4, 597.5±186.3) and group 3 (19.8 ± 5.1, 10.2 ± 1.6, 485.6 ± 157.7) respectively. Schirmer’s test values and tear film break up time were similar in both sexes (p=0.1 and p= 0.9). Tear meniscus

  6. Avalanches in insulating gases

    International Nuclear Information System (INIS)

    Verhaart, H.F.A.

    1982-01-01

    Avalanches of charged particles in gases are often studied with the ''electrical method'', the measurement of the waveform of the current in the external circuit. In this thesis a substantial improvement of the time resolution of the measuring setup, to be used for the electrical method, is reported. The avalanche is started by an N 2 -laser with a pulse duration of only 0.6 ns. With this laser it is possible to release a high number of primary electrons (some 10 8 ) which makes it possible to obtain sizeable signals, even at low E/p values. With the setup it is possible to analyze current waveforms with a time resolution down to 1.4 ns, determined by both the laser and the measuring system. Furthermore it is possible to distinguish between the current caused by the electrons and the current caused by the ions in the avalanche and to monitor these currents simultaneously. Avalanche currents are measured in N 2 , CO 2 , O 2 , H 2 O, air of varying humidity, SF 6 and SF 6 /N 2 mixtures. Depending on the nature of the gas and the experimental conditions, processes as diffusion, ionization, attachment, detachment, conversion and secondary emission are observed. Values of parameters with which these processes can be described, are derived from an analysis of the current waveforms. For this analysis already published theories and new theories described in this thesis are used. The drift velocity of both the electrons and the ions could be easily determined from measured avalanche currents. Special attention is paid to avalanches in air becasue of the practical importance of air insulation. (Auth.)

  7. Noble gases solubility in water

    International Nuclear Information System (INIS)

    Crovetto, Rosa; Fernandez Prini, Roberto.

    1980-07-01

    The available experimental data of solubility of noble gases in water for temperatures smaller than 330 0 C have been critically surveyed. Due to the unique structure of the solvent, the solubility of noble gases in water decreases with temperature passing through a temperature of minimum solubility which is different for each gas, and then increases at higher temperatures. As aresult of the analysis of the experimental data and of the features of the solute-solvent interaction, a generalized equation is proposed which enables thecalculation of Henry's coefficient at different temperatures for all noble gases. (author) [es

  8. MR imaging of meniscal tears: correlation with history of trauma

    International Nuclear Information System (INIS)

    Choi, Jong Cheul; Yang, Seoung Oh; Choi, Sun Seob; Son, Seok Hyun; Lee, Yung Il; Chung, Duck Hwan; Kim, Kyung Taek; Sohn, Sung Keun; Lee, Jung Yoon

    1994-01-01

    The medial meniscus is injured much more than the lateral meniscus. Because the medial meniscus is much larger in diameter, is thinner in its periphery and narrower in body than the lateral meniscus, and dose not attach to either cruciate ligament. We evaluated correlations with sites of tear and history of trauma. We reviewed retrospectively in 43 patients with meniscal tears on MR(51 cases) and correlated them with history of trauma. The most common site of injury was the posterior horn of the medial meniscuc(32/51), but high incidence of lateral meniscal tear compared with previous reports was seen. In the cases which had history of trauma, the posterior horn of medial meniscus was most commonly injured(26/34) and 5 meniscal tears were combined with meniscal tear in the other site. The tear in the anterior horn of the medial meniscus was seen only in a patient which had history of trauma and combined with meniscal tear in the other site. But in the meniscal tears without definite history of trauma, the incidence of meniscal tear was different from the meniscal tear with history of trauma. The incidence of lateral meniscal tear(11/17) was higher than medial meniscal tear and the posterior horn of lateral meniscus was commonly injured. We concluded that the medial meniscus was commonly injured, especially posterior horn, but in the cases which had no definite history of trauma, the lateral meniscus was commonly injured. An awareness of prevalent site of meniscal injuries may be helpful in the diagnostic interpretation of MR imaging of knee

  9. Effect of blinking on tear elimination as evaluated by dacryoscintigraphy

    International Nuclear Information System (INIS)

    White, W.L.; Glover, A.T.; Buckner, A.B.

    1991-01-01

    To document the change in drainage of tears that occurs with blinking, the authors evaluated 17 lacrimal systems of 12 individuals with dacryoscintigraphy. A significant difference in tear drainage was found by keeping the eyelids closed during the first 2 minutes after drop placement (P less than 0.03), but not from 2 to 5 minutes (P greater than 0.4). Retardation of tear drainage after droplet placement can be achieved by simple eyelid closure for 2 minutes

  10. Changes of tear film after trabeculectomy in glaucoma

    Directory of Open Access Journals (Sweden)

    Xue-Jun Li

    2015-07-01

    Full Text Available AIM: To learn the changes of the tear film before and after the trabeculectomy of glaucoma and explore the incidence of dry eye and the prevention and control measures.METHODS: The 36 patients(60 eyesof glaucoma were examined in detail before 3d of trabeculectomy and after the surgery at 3, 7, 14 and 30d. The examinations include lower eyelid central river of tears, break-up time(BUT, Schirmer Ⅰ test(SⅠtand staining scores of corneal fluorescein under slit lamp microscope.RESULTS:The tear meniscus height of central lower eyelid was increased and the tear film BUT was shortened at the same time, the scores of SⅠt was reduced and corneal fluorescein staining score was increased at postoperative 3 and 7d compared with that of preoperation. The tear meniscus height of central lower eyelid, tear film BUT and SIt and score of corneal fluorescein staining began to recover in most of the affected eyes after surgery 14d. At 30d after surgery, 22% of patients tear film failed to recover to the preoperative level; dry eye occured in 18% preoperative eyes with normal tear film.CONCLUSION:Trabeculectomy of glaucoma may affect the stability of the tear film and some patients showeing obvious dry eye and should be intervened and treatmented timely.

  11. Lipid peroxidation is increased in tears from the elderly.

    Science.gov (United States)

    Benlloch-Navarro, Soledad; Franco, Ilenia; Sánchez-Vallejo, Violeta; Silvestre, Dolores; Romero, Francisco Javier; Miranda, María

    2013-10-01

    We describe a procedure in which tears, obtained from Schirmer strips, are used to measure a marker of lipid peroxidation, malondialdehyde (MDA). We also compared the levels of proteins and MDA in tears from two groups of people: young adults (18-30 years old) and elderly adults (65-85 years old), because the data related to total protein concentration of human tears vary widely and because the majority of people over the age of 65 experience some symptoms of dry eyes and this condition has been recognized as an oxidative stress-induced disease. Our results show a significant difference in the protein concentration of the tears taken from the two age categories, younger adults (18-30 years old) and older adults (65-85 years old). Herein, we report for the first time an increase in MDA concentrations determined by HPLC in human tears based on age. It is possible that alterations in the tear lipid layer may lead to an increase in lipid peroxidation. Further studies are needed to understand the nature and function of tear film and stability in order to obtain new methods to analyze tears in patients with different diseases. In this sense, it would be interesting to compare MDA concentration in tears from control subjects and from people with meibomian gland dysfunction. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Effects of tear film dynamics on quality of vision.

    Science.gov (United States)

    Koh, Shizuka; Tung, Cynthia I; Inoue, Yasushi; Jhanji, Vishal

    2018-06-15

    The precorneal tear film is maintained by blinking and exhibits different phases in the tear cycle. The tear film serves as the most anterior surface of the eye and plays an important role as a first refractive component of the eye. Alterations in tear film dynamics may cause both vision-related and ocular surface-related symptoms. Although the optical quality associated with the tear film dynamics previously received little attention, objective measurements of optical quality using wavefront sensors have enabled us to quantify optical aberrations induced by the tear film. This has provided an objective method for assessing reduced optical quality in dry eye; thus, visual disturbances were included in the definition of dry eye disease in the 2007 Dry Eye Workshop report. In addition, sequential measurements of wavefront aberrations have provided us with valuable insights into the dynamic optical changes associated with tear film dynamics. This review will focus on the current knowledge of the mechanisms of wavefront variations that are caused by different aspects of tear film dynamics: specifically, quality, quantity and properties of the tear film, demonstrating the respective effects of dry eye, epiphora and instillation of eye drops on the quality of vision. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  13. Accuracy of MR imaging in partial tears of rotator cuff

    International Nuclear Information System (INIS)

    Eto, Masao; Ito, Nobuyuki; Tomonaga, Tadashi; Harada, Shin'ichi; Rabbi, M.E.; Iwasaki, Katsuro

    1997-01-01

    MRI is very useful for the diagnosis of the rotator cuff tear However. in case of partial tears it is sometimes controvertible. In this study, we studied the accuracy of MRI in the diagnosis of partial tears. 67 patients who underwent MRI investigation before operation were chosen for this study. There were 61 males and 6 females, ranging from 30 to 80 years (mean: 54.8 years at the time of operation). MRI was performed with 1.5T superconductive system with shoulder surface coil. MPGR T2-weighted images were performed in the coronal oblique and sagittal oblique planes. Complete tears were diagnosed when full thickness high intensity was observed in the rotator cuff, whereas with partial high intensity of the rotator cuff, was considered as partial tears. MRI demonstrated 77.8% sensitivity, 91.4% specificity and 89.6% accuracy in the diagnosis of partial tear. In 8 cases MRI had misinterpretation. In MPGR T2-weighted images, not only the partial tears but the degenerative changes also show high intensity of the rotator cuff. Therefore, it is difficult to differentiate and maybe this is the reason of misinterpretations of partial tears by MRI. MRI provided with useful pre-operative informations of partial tears of the rotator cuff. However, in few cases it is hard to differentiate for the degenerative changes of the rotator cuff. (author)

  14. Assessment and treatment strategies for rotator cuff tears

    Science.gov (United States)

    Al-Hakim, Wisam; Noorani, Ali

    2014-01-01

    Tears of the rotator cuff are common and becoming an increasingly frequent problem. There is a vast amount of literature on the merits and limitations of the various methods of clinical and radiological assessment of rotator cuff tears. This is also the case with regard to treatment strategies. Certain popular beliefs and principles practiced widely and the basis upon which they are derived may be prone to inaccuracy. We provide an overview of the historical management of rotator cuff tears, as well as an explanation for how and why rotator cuff tears should be managed, and propose a structured methodology for their assessment and treatment. PMID:27582960

  15. Progression of Fatty Muscle Degeneration in Atraumatic Rotator Cuff Tears.

    Science.gov (United States)

    Hebert-Davies, Jonah; Teefey, Sharlene A; Steger-May, Karen; Chamberlain, Aaron M; Middleton, William; Robinson, Kathryn; Yamaguchi, Ken; Keener, Jay D

    2017-05-17

    The purpose of this prospective study was to examine the progression of fatty muscle degeneration over time in asymptomatic shoulders with degenerative rotator cuff tears. Subjects with an asymptomatic rotator cuff tear in 1 shoulder and pain due to rotator cuff disease in the contralateral shoulder were enrolled in a prospective cohort. Subjects were followed annually with shoulder ultrasonography, which evaluated tear size, location, and fatty muscle degeneration. Tears that were either full-thickness at enrollment or progressed to a full-thickness defect during follow-up were examined. A minimum follow-up of 2 years was necessary for eligibility. One hundred and fifty-six shoulders with full-thickness rotator cuff tears were potentially eligible. Seventy shoulders had measurable fatty muscle degeneration of at least 1 rotator cuff muscle at some time point. Patients with fatty muscle degeneration in the shoulder were older than those without degeneration (mean, 65.8 years [95% confidence interval (CI), 64.0 to 67.6 years] compared with 61.0 years [95% CI, 59.1 to 62.9 years]; p tears at baseline was larger in shoulders with degeneration than in shoulders that did not develop degeneration (13 and 10 mm wide, respectively, and 13 and 10 mm long; p Tears with fatty muscle degeneration were more likely to have enlarged during follow-up than were tears that never developed muscle degeneration (79% compared with 58%; odds ratio, 2.64 [95% CI, 1.29 to 5.39]; p muscle degeneration occurred more frequently in shoulders with tears that had enlarged (43%; 45 of 105) than in shoulders with tears that had not enlarged (20%; 10 of 51; p tears with enlargement and progression of muscle degeneration were more likely to extend into the anterior supraspinatus than were those without progression (53% and 17%, respectively; p tear size (p = 0.56). The median time from tear enlargement to progression of fatty muscle degeneration was 1.0 year (range, -2.0 to 6.9 years) for the

  16. MR imaging of the traumatic triangular fibrocartilaginous complex tear

    Science.gov (United States)

    Griffith, James F.; Fung, Cindy S. Y.; Lee, Ryan K. L.; Tong, Cina S. L.; Wong, Clara W. Y.; Tse, Wing Lim; Ho, Pak Cheong

    2017-01-01

    Triangular fibrocartilage complex is a major stabilizer of the distal radioulnar joint (DRUJ). However, triangular fibrocartilage complex (TFCC) tear is difficult to be diagnosed on MRI for its intrinsic small and thin structure with complex anatomy. The purpose of this article is to review the anatomy of TFCC, state of art MRI imaging technique, normal appearance and features of tear on MRI according to the Palmar’s classification. Atypical tear and limitations of MRI in diagnosis of TFCC tear are also discussed. PMID:28932701

  17. Quotation systems for greenhouse gases

    International Nuclear Information System (INIS)

    Trong, Maj Dang

    2000-01-01

    The article surveys recommendations from a Norwegian committee for implementing at a national level, the Kyoto protocol aims for reducing the total emissions of greenhouse gases from the industrial countries through quotation systems

  18. Greenhouse gases and global warming

    International Nuclear Information System (INIS)

    1995-01-01

    From previous articles we have learned about the complexities of our environment, its atmosphere and its climate system. we have also learned that climate change and, therefore global warm and cool periods are naturally occurring phenomena. Moreover, all scientific evidence suggests that global warming, are likely to occur again naturally in the future. However, we have not yet considered the role of the rates of climate change in affecting the biosphere. It appears that how quickly the climate changes may be more important than the change itself. In light of this concern, let us now consider the possibility that, is due to human activity. We may over the next century experience global warming at rates and magnitudes unparalleled in recent geologic history. The following questions are answered; What can we learn from past climates? What do we know about global climates over the past 100 years? What causes temperature change? What are the greenhouse gases? How much have concentration of greenhouse gases increased in recent years? Why are increases in concentrations of greenhouse of concern? What is the e nhanced greenhouse effect ? How can human activity impact the global climate? What are some reasons for increased concentrations of greenhouse gases? What are fossil fuel and how do they transform into greenhouse gases? Who are the biggest emitters of greenhouse gases? Why are canada per capita emissions of greenhouse gases relatively high? (Author)

  19. Time course of changes in tear meniscus radius and blink rate after instillation of artificial tears.

    Science.gov (United States)

    Bandlitz, Stefan; Purslow, Christine; Murphy, Paul J; Pult, Heiko

    2014-08-26

    Using a novel digital meniscometer (PDM), alterations in tear meniscus radius (TMR) were measured simultaneously with blink rate (BR) following the instillation of artificial tears. Central TMR and BR of 22 subjects (11 male and 11 female; mean age, 24.3 ± 2.6 SD years) were measured at baseline, and 0, 1, 5, 10, and 30 minutes after instillation of an artificial tear containing hydroxypropyl-guar and glycol (SYS) or saline (SAL). A dose of 35 μL was applied in one eye in a randomized order with a washout period between each drop. For SAL, compared to baseline TMR (0.33 ± 0.08 mm), TMR significantly increased with drop instillation (1.55 ± 0.69 mm) and at 1 minute (0.66 ± 0.36 mm; P tears. Difference in residence time reflects the different viscosity of each drop. An overload with a large drop may result in an initially increased BR. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  20. MR Imaging of Rotator Cuff Tears: Correlation with Arthroscopy

    Science.gov (United States)

    Bhandary, Sudarshan; Khandige, Ganesh; Kabra, Utkarsh

    2017-01-01

    Introduction Rotator cuff tears are quite common and can cause significant disability. Magnetic Resonance Imaging (MRI) has now emerged as the modality of choice in the preoperative evaluation of patients with rotator cuff injuries, in view of its improved inherent soft tissue contrast and resolution. Aim To evaluate the diagnostic accuracy of routine MRI in the detection and characterisation of rotator cuff tears, by correlating the findings with arthroscopy. Materials and Methods This prospective study was carried out between July 2014 and August 2016 at the AJ Institute of Medical Sciences, Mangalore, Karnataka, India. A total of 82 patients were diagnosed with rotator cuff injury on MRI during this period, out of which 45 patients who underwent further evaluation with arthroscopy were included in this study. The data collected was analysed for significant correlation between MRI diagnosis and arthroscopic findings using kappa statistics. The sensitivity, specificity, predictive value and accuracy of MRI for the diagnosis of full and partial thickness tears were calculated using arthroscopic findings as the reference standard. Results There were 27 males and 18 females in this study. The youngest patient was 22 years and the oldest was 74 years. Majority of rotator cuff tears (78%) were seen in patients above the age of 40 years. MRI showed a sensitivity of 89.6%, specificity of 100%, positive predictive value of 100% and negative predictive value of 83.3% for the diagnosis of full thickness rotator cuff tears. For partial thickness tears, MRI showed a sensitivity of 100%, specificity of 86.6%, positive predictive value of 78.9% and negative predictive value of 100%. The accuracy was 93.1% for full thickness tears and 91.1% for partial thickness tears. The p-value was less than 0.01 for both full and partial thickness tears. There was good agreement between the MRI and arthroscopic findings, with kappa value of 0.85 for full thickness tears and 0.81 for partial

  1. Role of MRI in predicting meniscal tear reparability

    Energy Technology Data Exchange (ETDEWEB)

    Felisaz, Paolo Florent [Universita degli Studi di Pavia, Pavia (Italy); Fondazione IRCCS Policlinico San Matteo, Istituto di Radiologia, Pavia (Italy); Alessandrino, Francesco; Perelli, Simone [Universita degli Studi di Pavia, Pavia (Italy); Zanon, Giacomo; Benazzo, Francesco [Fondazione IRCCS Policlinico San Matteo, Clinica Ortopedica e Traumatologica, Pavia (Italy); Calliada, Fabrizio; Sammarchi, Luigi [Fondazione IRCCS Policlinico San Matteo Radiologia, Diagnostica per Immagini-Istituto di Radiologia, Pavia (Italy)

    2017-10-15

    To elucidate the role of MRI in predicting meniscal tear reparability according to tear type and location in relation to vascular zones. In this retrospective study, two readers evaluated 79 pre-surgical MRIs of meniscal tears arthroscopically treated with meniscectomy or meniscal repair. Tears were classified according to type into vertical, horizontal, radial, complex, flaps and bucket handle and were considered reparable if the distance measured from the tear to the menisco-capsular junction was less than or equal to 5 mm. Predictions were compared with the surgical procedure performed in arthroscopy. We assessed the diagnostic performance of MRI, agreement between MRI and arthroscopy, and interrater agreement. Then, we conducted an ROC analysis on the distances measured by the first reader and built a multivariate logistic regression model. MRI had a sensitivity, specificity, PPV, NPV and accuracy, respectively, of 85%, 79%, 86%, 76% and 83% in predicting meniscal tear reparability. Correct predictions for the specific tear pattern were 76% for vertical, 84% for horizontal, 88% for radial, 86% for complex, 84% for flaps and 86% for bucket handle. Agreement between the two readers' predictions and arthroscopy was good (k = 0.65 and 0.61, respectively). Inter-rater agreement was almost excellent (k = 0.79). The ROC analysis revealed sensitivity and specificity of 73% and 83% with a cutoff value of <4 mm (p < 0.001). Anterior cruciate ligament injury and medial meniscal tear increased the likelihood of meniscal tear reparability. MRI can be a reliable and accurate tool to predict the reparability of meniscal tears, with higher prediction rates for bucket-handle tears. (orig.)

  2. Long-Term MRI Findings in Operated Rotator Cuff Tear

    International Nuclear Information System (INIS)

    Kyroelae, K.; Niemitukia, L.; Jaroma, H.; Vaeaetaeinen, U.

    2004-01-01

    Purpose: To describe magnetic resonance imaging (MRI) findings at long-term follow-up after rotator cuff (RC) tear using standard MRI sequences without fat saturation. Material and Methods: Twenty-eight patients aged 55.8±7.6 underwent MRI examination 4.6±2.1 years after surgery for RC tear. Standard sequences in oblique coronal, oblique sagittal, and axial planes were obtained. The RC, including re-tears and tendon degeneration, was independently evaluated by two observers. Thickness of the supraspinatus tendon and narrowing of the subacromial space were measured. The clinical outcome was evaluated with the Constant score and compared with the MRI findings. Results: The RC tear was traumatic in 18 (64%) patients and degenerative in 10 (36%). At follow-up, 11 (39%) had normal RC tendons with good clinical outcome. Four (14%) patients had painful tendinosis without RC tear. A full-thickness RC tear was found in 7 (25%) patients and a partial tear in 6 (21%). In one patient with a full-thickness tear, and in two with partial tear, tendinosis was found in another of the RC tendons. The subacromial space was narrowed in 13 (46%) of the patients. A narrowing of the subacromial space correlated with re-tear (P<0.05). Conclusions: The RC may be evaluated with standard MRI sequences without fat saturation at long-term follow-up. A normal appearance of the RC is correlated with good clinical outcome, while re-tear and tendinosis are associated with pain

  3. SLAP tears of the glenoid labrum in contact athletes.

    Science.gov (United States)

    Funk, Lennard; Snow, Martyn

    2007-01-01

    To describe the distribution and clinical presentation of labral injuries in rugby players and the time taken for them to return to sports. Retrospective cohort study. Busy shoulder practice in the North West of England, treating a large number of professional athletes. A review of 51 shoulder arthroscopies performed on professional rugby players over a 35 month period. All patients diagnosed with a SLAP lesion at arthroscopy were identified. Eighteen patients had a documented SLAP tear; this group represented our study population. Arthroscopic debridement and/or stabilization was carried out for all labral injuries using Panaloc anchors and No. 2 PDS via a 2 portal technique. Classification of injury, Satisfaction, Time to return to play. The incidence of SLAP tears in our study population was 35%. There were 11 isolated SLAP tears (61%), 3 SLAP tears associated with a Bankart lesion (17%), 2 SLAP tears associated with a posterior labral lesion (11%), and 2 SLAP tears associated with an anterior and posterior labral injuries (11%). Of the 18 SLAP tears, 14 (78%) were type 2, 3 (17%) were type 3, and 1 (5%) was type 4. None of the patients with a SLAP tear presented with symptoms of instability. MR Arthrogram had a 76% sensitivity for detecting SLAP tears. By 6 months postsurgery, 89% of patients were satisfied. Patients with isolated SLAP tears were the quickest to return to sports, at an average of 2.6 months postsurgery. SLAP tears are a common injury in rugby players. These can often be diagnosed with MR arthrography. Arthroscopic repair is associated with excellent results and early return to sports.

  4. Treatment for acute anterior cruciate ligament tear

    DEFF Research Database (Denmark)

    Frobell, Richard B; Roos, Harald P; Roos, Ewa M

    2015-01-01

    STUDY QUESTION: In young active adults with an acute anterior cruciate ligament (ACL) rupture, do patient reported or radiographic outcomes after five years differ between those treated with rehabilitation plus early ACL reconstruction and those treated with rehabilitation and optional delayed AC...... AND WHAT THIS PAPER ADDS: The relative efficacy of surgical reconstruction and rehabilitation for short and long term outcomes of ACL rupture is debated. Clinicians and young active adult patients should consider rehabilitation as a primary treatment option following an acute ACL tear....

  5. Tearing instability in cylindrical plasma configuration

    International Nuclear Information System (INIS)

    Zelenyj, L.M.

    1979-01-01

    The effect of the neutral-layer cylindrical geometry on the development of the tearing instability has been investigated in detail. The increments of the instability for all the regimes have been found. The influence of cylindrical effects becomes manifesting itself at small, as compared to the layer characteristic thickness, distances from the axis, and, finally, the electron regime of the instability development transforms into an ion one. The results obtained are of interest for studying the plasma stability in the devices of the ''Astron'' type and in magnetospheres of cosmic objects

  6. [The correlations between corneal sensation, tear meniscus volume, and tear film osmolarity after femtosecond laser-assisted LASIK].

    Science.gov (United States)

    Zhang, Luyan; Sun, Xiyu; Yu, Ye; Xiong, Yan; Cui, Yuxin; Wang, Qinmei; Hu, Liang

    2016-01-01

    To investigate the correlations between corneal sensation, tear meniscus volume, and tear film osmolarity after femtosecond laser-assisted LASIK (FS-LASIK) surgery. In this prospective clinical study, 31 patients undergoing FS-LASIK for myopia were recruited. The upper and lower tear meniscus volumes (UTMV and LTMV) were measured by customized anterior segment optical coherence tomography, tear film osmolarity was measured by a TearLab Osmolarity test device, central corneal sensation was measured by a Cochet-Bonner esthesiometer preoperatively, at 1 week, 1 and 3 months postoperatively. Repeated measures analysis of variance was used to evaluate whether the tear film osmolarity, tear meniscus volume, and corneal sensation were changed after surgery. The correlations between these variables were analyzed by the Pearson correlation analysis. The tear film osmolarity was (310.03 ± 16.48) mOsms/L preoperatively, (323.51 ± 15.92) mOsms/L at 1 week, (319.93 ± 14.27) mOsms/L at 1 month, and (314.97±12.91) mOsms/L at 3 months. The UTMV was (0.42±0.15), (0.25± 0.09), (0.30±0.11), and (0.35±0.09) μL, respectively; the LTMV was (0.60±0.21),(0.37±0.08), (0.44± 0.14), and (0.52±0.17) μL, respectively. The tear film osmolarity was significantly higher at 1 week and 1 month postoperatively compared with the baseline (P=0.001, 0.004), and reduced to the preoperative level at 3 months (P=0.573). The UTMV, LTMV, and corneal sensation values presented significant decreases at all postoperative time points (all Psensation at 1 week after surgery (r=0.356,P=0.005). There were significant correlations between the preoperative LTMV and corneal sensation at 1 week, 1 and 3 months (respectively, r=0.422, 0.366, 0.352;P=0.001, 0.004, 0.006). No significant correlations were found between the tear film osmolarity, tear meniscus volume, and corneal sensation after surgery (all P>0.05). The tear film osmolarity, tear meniscus volume, and corneal sensation became aggravated due

  7. Rotator cuff tears: correlation between geometric tear patterns on MRI and arthroscopy and pre- and postoperative clinical findings.

    Science.gov (United States)

    Sela, Yaron; Eshed, Iris; Shapira, Shachar; Oran, Ariel; Vogel, Guy; Herman, Amir; Perry Pritsch, Moshe

    2015-02-01

    Magnetic resonance imaging (MRI) is considered to be the best non-invasive procedure for the evaluation of rotator cuff (RC) tendon tears. Burkhart's classification is a geometric classification of full-thickness RC tears on MRI. To correlate MRI and arthroscopic geometric full-thickness RC tears according to the Burkhart's classification with pre- and postoperative clinical findings. Patients who underwent arthroscopic RC repair between 2006 and 2010 were retrospectively evaluated. Preoperative MRI and arthroscopic surgical reports were reviewed for tear geometry (Burkhart's) by three (1 radiologist, 2 surgeons) and two (surgeons) readers. MRIs were also evaluated for tear size and change of tear size in successive sagittal sections and for muscle mass and fatty infiltration. Clinical examinations were performed preoperatively and at least 12 months afterwards. Postoperative function questionnaires were filled in by the patients. Forty-six patients (35 men, 11 women; mean age, 57 years; range, 41-72 years) were evaluated. Tears depicted on MRIs were classified as crescent in 11 patients (24%), longitudinal in three (6.5%), massive contracted in 29 (63%), and cuff arthropathy in three (6.5%). Muscle changes were noted almost exclusively in patients with massive tears and cuff arthropathy (16/32 patients, P = 0.013). MRIs and arthroscopic geometric classifications were in close agreement. Tear type did not correlate with pre- and postoperative physical examination or with postoperative clinical questionnaires scores. Geometric RC tear characterizations on preoperative MRIs were closely associated with arthroscopic findings. Postoperative results were not affected by the geometric pattern of the tears. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  8. Radioactive gases monitor system: tritium, radon, noble gases

    International Nuclear Information System (INIS)

    Egey, J.Z.; Matatagui, E.

    2015-01-01

    A system for monitoring the radioactive gases tritium, radon and noble gases is described. We present the description of the sensor and the associated electronics that have been developed to monitor the presence of radioactive gases in air or other gaseous effluents. The system has a high sensitivity and a wide range of operation. The sensor is an ionization chamber, featuring the internal circulation of the gas to monitor and the associated electronics has a resolution better than 10 E-15A (fA). It allows the detection of the individual pulses that are produced during the alpha decay of radon and its daughter elements. The measurement system is made up of a commercial data acquisition system connected to a computer. The acquired data is presented on a graphical display and it is stored for later processing and analysis. We have a system that is of simple construction and versatile. Here we present the experimental results. (authors) [es

  9. Tear film lipid layer: A molecular level view

    Czech Academy of Sciences Publication Activity Database

    Cwiklik, Lukasz

    2016-01-01

    Roč. 1858, č. 10 (2016), s. 2421-2430 ISSN 0005-2736 R&D Projects: GA ČR GA15-14292S Institutional support: RVO:61388955 Keywords : tear film * tear film lipid layer * molecular dynamics simulations Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 3.498, year: 2016

  10. Why only humans shed emotional tears : Evolutionary and cultural perspectives

    NARCIS (Netherlands)

    Gracanin, A.; Bylsma, L.M.; Vingerhoets, A.J.J.M.

    Producing emotional tears is a universal and uniquely human behavior. Until recently, tears have received little serious attention from scientists. Here, we summarize recent theoretical developments and research findings. The evolutionary approach offers a solid ground for the analysis of the

  11. Tearing mode stability of tokamak plasmas with elliptical cross section

    International Nuclear Information System (INIS)

    Carreras, B.A.; Holmes, J.A.; Hicks, H.R.; Lynch, V.E.

    1981-02-01

    The effect of the ellipticity of the plasma cross section on tearing mode stability is investigated. The induced coupling between modes is shown to be destabilizing; however, the modification of the equilibrium tends to stabilize the tearing modes. The net effect depends on the manner in which the equilibrium is modified as the plasma cross-section shape is changed

  12. The Effect of Polar Lipids on Tear Film Dynamics

    KAUST Repository

    Aydemir, E.; Breward, C. J. W.; Witelski, T. P.

    2010-01-01

    In this paper, we present a mathematical model describing the effect of polar lipids, excreted by glands in the eyelid and present on the surface of the tear film, on the evolution of a pre-corneal tear film. We aim to explain the interesting

  13. A study of re-tear cases after ARCR

    International Nuclear Information System (INIS)

    Ishida, Yasuyuki; Chosa, Etsuo; Yano, Hiroaki

    2011-01-01

    Recently, good clinical outcomes of arthroscopic rotator cuff repair (ARCR) are reported, but the re-tear rate of massive and large rotator cuff tears is still high. The purpose of this study is to review the clinical outcome and postoperative cuff integrity of ARCR in our hospital. We evaluated 80 shoulders (61 males, 19 females), whose age rauged from 30 to 78 (average: 61.8 years old). The size of tears were 8 small, 22 medium, 36 large, and 14 massive. We evaluated the pre-and postoperative Japanese Orthopedic Association (JOA) scored, and MRI findings 12 months postoperatively. We evaluated the cuff integrity and fatty degeneration of the ruptured cuff by Goutallier's classification. Postoperative MRI findings showed complete repair in 56 shoulders (70%) and re-tear in 24 shoulders (30%). Postoperative JOA score was poor in cases with large re-tears. Retear rates were high in large and massive tears, tears with advanced fatty degeneration, and subscapularis tears. As this operation is not a replacement procedure, the quality of the ruptured rotator cuff is important. Further discussion on the operative indication and method is necessary. (author)

  14. MRI evaluation of the posterior meniscus root tear

    International Nuclear Information System (INIS)

    Zhang Jianjun; Zheng Zhuozhao; Li Xuan

    2010-01-01

    Objective: To determine the value of MRI for diagnosing the posterior meniscus root tear. Methods: MR examinations of 30 patients with tear of the posterior meniscus root confirmed by knee arthroscopies were retrospectively reviewed. Of the 30 patients, 17 with posterior medial meniscus root tear (MMRT) and 13 with posterior lateral meniscus root tear (LMRT). The diagnostic sensitivity of' MRI for the posterior meniscus root tear was analyzed. Fisher's exact test was used to compare the detection rate of MRI for MMRT with that for LMRT. Results: All 17 cases with MMRT and 9 cases out of 13 with LMRT were correctly diagnosed by MRI and the diagnostic sensitivity of MRI for the posterior meniscus root tear was 86.7% (26/30). The main MR appearance of the posterior meniscus root tear was distortion of the meniscal root, with its low signal replaced by abnormal high signal. The detection rate of MRI for MMRT (17/17) was significantly greater than that for LMRT (9/13) (P=0.026). The prevalence of MMRT associated with meniscus extrusion (15/17) was significantly greater than that of LMRT (6/13) (P=0.020), but the prevalence of MMRT associated with anterior cruciate ligament (ACL) injury (5/17) was significantly lower than that of LMRT (11/13) (P=0.004). Conclusion: MRI is a relatively good method for detection of posterior meniscus root tears and associated injuries. (authors)

  15. Nonlinear tearing mode and vortex chains

    International Nuclear Information System (INIS)

    Jovanovic, D.; Vranjes, J.

    1996-01-01

    We study the nonlinear stage of a tearing mode, whose island width exceeds the tearing layer thickness, and the wavelength is of the order of collisionless skin depth. A coherent solution is found in the form of a moving vortex chain. It is the result of a self-organization process, which adjusts the profile of the sheared poloidal magnetic field and excites a localized perpendicular sheared plasma flow, consisting of three counterstreaming jets. A numerical solution shows a twin chain of plasma vortices, coupled with a single chain of magnetic islands, whose width is of the order of collisionless skin depth. Adiabatic evolution of the vortex chain in the presence of small viscosity reveals its finite lifetime. The chain destruction may occur either directly, or through a sequence of bifurcations (corresponding to abrupt changes of the vortex chain parameters) to magnetic field stochastization within a layer of the collisionless skin depth scale, which occurs before the magnetic island overlapping takes place. This provides a new mechanism for the anomalous transport. (orig.)

  16. Forced tearing of ductile and brittle thin sheets.

    Science.gov (United States)

    Tallinen, T; Mahadevan, L

    2011-12-09

    Tearing a thin sheet by forcing a rigid object through it leads to complex crack morphologies; a single oscillatory crack arises when a tool is driven laterally through a brittle sheet, while two diverging cracks and a series of concertinalike folds forms when a tool is forced laterally through a ductile sheet. On the other hand, forcing an object perpendicularly through the sheet leads to radial petallike tears in both ductile and brittle materials. To understand these different regimes we use a combination of experiments, simulations, and simple theories. In particular, we describe the transition from brittle oscillatory tearing via a single crack to ductile concertina tearing with two tears by deriving laws that describe the crack paths and wavelength of the concertina folds and provide a simple phase diagram for the morphologies in terms of the material properties of the sheet and the relative size of the tool.

  17. Gases and carbon in metals

    International Nuclear Information System (INIS)

    Jehn, H.; Fromm, E.; Hoerz, G.

    1978-01-01

    This issue is part of a series of data on 'gases and carbon in metals'. The present survey includes results from papers dealing with gases and carbon in actinides and recommends critically selected data for each element. Firstly data od binary systems are presented, starting with hydrogen and followed by carbon, nitrogen, oxygen, and rare gases. Within one metal-metalloid system the data are listed under topics such as solubility limit, dissociation pressure of compunds, vapour pressure of volatile oxides, thermodynamic data, diffusion, transport parameters (effective valence, heat of transport), permeation of gases through metals, gas adsorption and gas desorption kinetics, compound formation, precipitation kinetics, and property changes. Following the data on binary systems, the data of ternary systems are presented, beginning with systems which contain one metal and two gases or one gas and carbon and continuing with systems with two metals and one gas or carbon. Within a ternary system the topics are arranged in the same way as in binary systems. (HB) [de

  18. Impact of environmental adaptation on tear film assessments.

    Science.gov (United States)

    Fagehi, R

    2018-03-01

    The purpose of this study was to investigate the effect of ocular environmental adaptation on clinical tear film assessment. Thirty subjects (male, mean age 23±2.5) participated in this study. A number of clinical tear film tests were applied, including: fluorescein tear break-up time (FTBUT), Schirmer test and tear prism height test (TPH). The tear physiology of each subject was evaluated twice, once immediately when they arrived from the external environment, and then after 30minutes adaptation in the exam room environment. The mean values were: Schirmer test A (22.1±2.99), Schirmer test B (24.2±2.63), FTBUT A (8.00±1.94), FTBUT B (9.13±2.04), TPH A (0.179±0.026) and TPH B* (0.187±0.023). Statistical testing using Wilcoxon-signed rank test showed a significant difference between the Schirmer test results measured at the different times (P=0.008). Also, the FTBUT and tear prism height test results showed significant differences between the two evaluation times, (P=0.001, 0.011, respectively) (A: tear assessed when the subject comes from the outside environment, B: tear film assessed after 30min adaptation in the clinical environment). This study showed a significant difference between the tear film test results evaluated when the subjects were assessed immediately from the outside environment and after an adaptation time in the clinic environment. Practitioners must consider the effect of differences between external and clinical environment adaptation on clinical tear film physiology. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  19. Warm and touching tears: tearful individuals are perceived as warmer because we assume they feel moved and touched.

    Science.gov (United States)

    Zickfeld, Janis H; Schubert, Thomas W

    2018-01-31

    Recent work investigated the inter-individual functions of emotional tears in depth. In one study (Van de Ven, N., Meijs, M. H. J., & Vingerhoets, A. (2017). What emotional tears convey: Tearful individuals are seen as warmer, but also as less competent. British Journal of Social Psychology, 56(1), 146-160. Https://doi.org/10.1111/bjso.12162) tearful individuals were rated as warmer, and participants expressed more intentions to approach and help such individuals. Simultaneously, tearful individuals were rated as less competent, and participants expressed less intention to work with the depicted targets. While tearful individuals were perceived as sadder, perceived sadness mediated only the effect on competence, but not on warmth. We argue that tearful individuals might be perceived as warm because they are perceived as feeling moved and touched. We ran a pre-registered extended replication of Van de Ven et al. Results replicate the warmth and helping findings, but not the competence and work effects. The increase in warmth ratings was completely mediated by perceiving feeling moved and touched. Possible functions of feeling moved and touched with regard to emotional tears are discussed.

  20. Desulphurization of exhaust gases in chemical processes

    Energy Technology Data Exchange (ETDEWEB)

    Asperger, K.; Wischnewski, W.

    1981-01-01

    The sulfur content of exhaust gases can be reduced by: desulphurization of fuels; modification of processes; or treatment of resultant gases. In this paper a few selected examples from the chemical industry in the German Democratic Republic are presented. Using modified processes and treating the resultant gases, the sulphuric content of exhaust gases is effectively reduced. Methods to reduce the sulfur content of exhaust gases are described in the field of production of: sulphuric acid; viscose; fertilizers; and paraffin.

  1. Effects of topical cyclosporine a plus artificial tears versus artificial tears treatment on conjunctival goblet cell density in dysfunctional tear syndrome.

    Science.gov (United States)

    Demiryay, Elvan; Yaylali, Volkan; Cetin, Ebru Nevin; Yildirim, Cem

    2011-09-01

    The aim was to compare the effects of topical cyclosporine A and artificial tears combination with artificial tears alone in patients with dysfunctional tear syndrome (DTS). Forty-two eyes of 42 patients with DTS were enrolled in the study. The inclusion criteria for the study were Schirmer I (without anesthesia) scores below 10 mm/5 min and tear film break-up time (BUT) below 10 sec. The patients were randomly divided into two groups. The study group (22 patients) underwent 0.05% cyclosporine A treatment twice a day and preservative-free artificial tears for four times a day for 4 months. The control group (20 patients) was administered only preservative-free artificial tears four times a day for 4 months. The BUT, Schirmer test scores, corneal fluorescein staining, conjunctival lissamine green staining, and goblet cell density derived by impression cytology were recorded before and after treatment in each group. In the study group, all parameters improved statistically significantly after treatment at the 4-month follow-up compared with the pretreatment values (Ptears treatment significantly increases goblet cell density, decreases the signs of DTS, and improves ocular surface health.

  2. Process for separating radioactive gases

    International Nuclear Information System (INIS)

    Kimura, Shigeru; Awada, Yoshihisa.

    1976-01-01

    Object: To efficiently and safely separate and recover raw gases such as krypton which requires radioactive attenuation by a long term storage. Structure: A mixture of krypton and xenon is separated by liquefaction from raw gases at a first distillation column, using latent heat of liquid nitrogen. The krypton and xenon mixture separated by liquefaction at the first distillation column is separated into krypton and xenon, by controlling operation pressure of a second distillation column at about 3 - 5 atm., using sensible heat of low temperature nitrogen gas discharged from a top of the first distillation column and a condenser. (Aizawa, K.)

  3. The ideal gases of tachyons

    International Nuclear Information System (INIS)

    Mrowczynski, St.

    1984-01-01

    The formalism of statistical mechanics of particles slower than light has been considered from the point of view of the application of this formalism for the description of tachyons. Properties of ideal gases of tachyons have been discussed in detail. After finding general formulae for quantum, Bose and Fermi gases the classical limit has been considered. It has been shown that Bose-Einstein condensation occurs. The tachyon gas of bosons violates the third principle of thermodynamics. Degenerated Fermi gas has been considered and in this case the entropy vanishes at zero temperature. Difficulties of formulating covariant statistical mechanics have been discussed

  4. A microscope for Fermi gases

    International Nuclear Information System (INIS)

    Omran, Ahmed

    2016-01-01

    This thesis reports on a novel quantum gas microscope to investigate many-body systems of fermionic atoms in optical lattices. Single-site resolved imaging of ultracold lattice gases has enabled powerful studies of bosonic quantum many-body systems. The extension of this capability to Fermi gases offers new prospects to studying complex phenomena of strongly correlated systems, for which numerical simulations are often out of reach. Using standard techniques of laser cooling, optical trapping, and evaporative cooling, ultracold Fermi gases of 6 Li are prepared and loaded into a large-scale 2D optical lattice of flexible geometry. The atomic distribution is frozen using a second, short-scaled lattice, where we perform Raman sideband cooling to induce fluorescence on each atom while maintaining its position. Together with high-resolution imaging, the fluorescence signals allow for reconstructing the initial atom distribution with single-site sensitivity and high fidelity. Magnetically driven evaporative cooling in the plane allows for producing degenerate Fermi gases with almost unity filling in the initial lattice, allowing for the first microscopic studies of ultracold gases with clear signatures of Fermi statistics. By preparing an ensemble of spin-polarised Fermi gases, we detect a flattening of the density profile towards the centre of the cloud, which is a characteristic of a band-insulating state. In one set of experiments, we demonstrate that losses of atom pairs on a single lattice site due to light-assisted collisions are circumvented. The oversampling of the second lattice allows for deterministic separation of the atom pairs into different sites. Compressing a high-density sample in a trap before loading into the lattice leads to many double occupancies of atoms populating different bands, which we can image with no evidence for pairwise losses. We therefore gain direct access to the true number statistics on each lattice site. Using this feature, we can

  5. Posterior horn medial meniscal root tear: the prequel

    Energy Technology Data Exchange (ETDEWEB)

    Umans, H. [Albert Einstein College of Medicine, Bronx, NY (United States); Lenox Hill Radiology and Imaging Associates, New York, NY (United States); Morrison, W. [Thomas Jefferson University Hospital, Philadelphia, PA (United States); DiFelice, G.S. [Hospital for Special Surgery, New York, NY (United States); Vaidya, N. [Crystal Run Healthcare, Middletown, NY (United States); Winalski, C.S. [Cleveland Clinic, Imaging Institute, Department of Biomedical Engineering, Lerner Research Institute, Cleveland, OH (United States)

    2014-06-15

    To determine whether subarticular marrow changes deep to the posterior horn medial meniscal root anchor might predict subsequent medial meniscal root tear. Fifteen patients with MR-diagnosed posterior horn medial meniscal root (PHMMR) tear and a knee MRI antecedent to the tear were identified at three imaging centers over a 7-year period. The pre- and post-tear MR images were evaluated for marrow signal changes deep to the root anchor, meniscal root signal intensity, medial compartment articular cartilage thinning, and meniscal body extrusion. Images of 29 age- and gender-matched individuals with two MRIs of the same knee were reviewed as a control group. MRI in 11 of 15 (73 %) cases with subsequent PHMMR tear demonstrated linear subcortical marrow edema deep to the meniscal root anchor on the antecedent MRI compared to only 1 of 29 (3 %) non-tear controls (p < 0.0001). The abnormal signal resolved on post-tear MRI in all but two patients. Cyst-like changes deep to the PHMMR were present on initial MRI in three of 15 (23 %) cases and three of 29 (10 %) controls, persisting in all but one case on follow-up imaging. The PHMMR was gray on the initial MRI in seven of 15 (47 %) of cases that developed tears compared to four of 29 (14 %) controls (p < 0.0001). There was medial meniscal extrusion (MME) prior to tear in two of 15 (13 %) patients and in ten of 15 (67 %) patients after PHMMR failure. In the control group, MME was present in one (3 %) and three (10 %) of 29 subjects on the initial and follow-up MRIs, respectively. Articular cartilage loss was noted in two of 15 (15 %) cases before tear and nine of 15 (69 %) on follow-up imaging, as compared to one (3 %) and four (14 %) of 29 subjects in the control group. Subcortical marrow edema deep to the PHMMR may result from abnormal stresses and thus be a harbinger of meniscal root failure. This hypothesis is supported by resolution of these marrow signal changes after root tear. Following tear, extrusion of the

  6. Cytokine changes in tears and relationship to contact lens discomfort.

    Science.gov (United States)

    Willcox, Mark D P; Zhao, Zhenjun; Naduvilath, Thomas; Lazon de la Jara, Percy

    2015-01-01

    To determine the reproducibility of a multiplex bead assay for measuring cytokines in tears and correlations between ocular discomfort with or without contact lens wear and the concentration of cytokines in tears. Ninety participants (divided into two groups) were enrolled in this prospective study. They were asked to rate their ocular comfort and collect their tears in the morning and just before sleep for 10 days with or without contact lenses. The participants collected their tears using a glass microcapillary tube for both stages. Galyfilcon A lenses were worn on a daily disposable basis during the contact lens stage, and comfort scores and tears were collected before lens insertion and prior to lens removal at the end of the day. Tears were analyzed for cytokine concentrations using a 27-plex multibead assay. Correlations were sought between cytokine concentrations and comfort. There was a significant (p-0.5 Log pg/ml, p-0.2 Log pg/ml, ptears was correlated to ocular comfort, but this was not changed by contact lens wear. Ocular comfort during the day is magnified by contact lens wear. However, the increase in the change in comfort during lens wear was not associated with changes in 15 cytokines in the tear film.

  7. Relationships between rotator cuff tear types and radiographic abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Soo Hyun; Chun, Kyung Ah; Lee Soo Jung; Kang, Min Ho; Yi, Kyung Sik; Zhang, Ying [Dept. of Diagnostic Radiology, College of Medicine, Chungbuk National University, Cheongju (Korea, Republic of)

    2014-11-15

    To determine relationships between different types of rotator cuff tears and radiographic abnormalities. The shoulder radiographs of 104 patients with an arthroscopically proven rotator cuff tear were compared with similar radiographs of 54 age-matched controls with intact cuffs. Two radiologists independently interpreted all radiographs for; cortical thickening with subcortical sclerosis, subcortical cysts, osteophytes in the humeral greater tuberosity, humeral migration, degenerations of the acromioclavicular and glenohumeral joints, and subacromial spurs. Statistical analysis was performed to determine relationships between each type of rotator cuff tears and radiographic abnormalities. Inter-observer agreements with respect to radiographic findings were analyzed. Humeral migration and degenerative change of the greater tuberosity, including sclerosis, subcortical cysts, and osteophytes, were more associated with full-thickness tears (p < 0.01). Subacromial spurs were more common for full-thickness and bursal-sided tears (p < 0.01). No association was found between degeneration of the acromioclavicular or glenohumeral joint and the presence of a cuff tear. Different types of rotator cuff tears are associated with different radiographic abnormalities.

  8. Relationships between rotator cuff tear types and radiographic abnormalities

    International Nuclear Information System (INIS)

    Lee, Soo Hyun; Chun, Kyung Ah; Lee Soo Jung; Kang, Min Ho; Yi, Kyung Sik; Zhang, Ying

    2014-01-01

    To determine relationships between different types of rotator cuff tears and radiographic abnormalities. The shoulder radiographs of 104 patients with an arthroscopically proven rotator cuff tear were compared with similar radiographs of 54 age-matched controls with intact cuffs. Two radiologists independently interpreted all radiographs for; cortical thickening with subcortical sclerosis, subcortical cysts, osteophytes in the humeral greater tuberosity, humeral migration, degenerations of the acromioclavicular and glenohumeral joints, and subacromial spurs. Statistical analysis was performed to determine relationships between each type of rotator cuff tears and radiographic abnormalities. Inter-observer agreements with respect to radiographic findings were analyzed. Humeral migration and degenerative change of the greater tuberosity, including sclerosis, subcortical cysts, and osteophytes, were more associated with full-thickness tears (p < 0.01). Subacromial spurs were more common for full-thickness and bursal-sided tears (p < 0.01). No association was found between degeneration of the acromioclavicular or glenohumeral joint and the presence of a cuff tear. Different types of rotator cuff tears are associated with different radiographic abnormalities.

  9. Coupling of tearing modes in tokamaks

    International Nuclear Information System (INIS)

    Finn, J.M.

    1977-01-01

    The simultaneous presence of tearing modes of different helical pitches leads to the destruction of magnetic surfaces, which has been suggested as the mechanism leading to the onset of the disruptive instability in tokamaks. For current profiles in which the m = 2 mode is unstable, but the m = 3 is stable, the coupling of the m = 3 to the m = 2 through the poloidal variation of the toroidal field can drive the m = 3 amplitude psi 3 to order psi 2 times the inverse aspect ratio. Detailed calculations, both analytical and numerical, have been performed for two models for the equilibrium and m = 2 mode structure. A slab model and incompressible m = 3 perturbations are assumed. The m = 3 amplitude increases with shear, up to a point, showing that as the current channel shrinks, overlap of resonances becomes more likely. The results also apply qualitatively to other m, m +- 1 interactions

  10. Anterior cruciate ligament tears: MRI versus arthroscopy

    International Nuclear Information System (INIS)

    Tosch, U.; Felix, R.; Schauwecker, W.; Dreithaler, B.

    1992-01-01

    Because of suspected rupture of the anterior cruciate ligament sixteen acute traumatised patients were investigated by MR and arthroscopy. The MR diagnosis of a lesion of the anterior cruciate ligament proved to be correct by arthroscopy in fifteen of sixteen cases. Diagnostic criteria for lesions of the anterior cruciate ligament were: increased signal intensity in T 1 - and T 2 weighted images, increased volume and discontinuity of ligamentous structures. Additional MR findings of meniscal tears were correct in three of four cases laterally and in four of four cases medially. Femoral cartilage lesions were correctly identified by MR in three cases. MR normal findings proved to be correct by arthroscopy in another five cases. (orig.) [de

  11. Transport processes in ionized gases

    International Nuclear Information System (INIS)

    Kremer, G.M.

    1997-01-01

    Based on kinetic theory of gases and on the combined of Chapman-Enskog and Grad, the laws of Ohm, Fourier and Navier-Stokes are derived for a non-relativistic fully ionized gas. Moreover, the combined method is applied to the BGK model of the relativistic Boltzmann equation and the Ohm's law is derived for a relativistic fully ionized gas. (author)

  12. Stratospheric aerosols and precursor gases

    Science.gov (United States)

    1982-01-01

    Measurements were made of the aerosol size, height and geographical distribution, their composition and optical properties, and their temporal variation with season and following large volcanic eruptions. Sulfur-bearing gases were measured in situ in the stratosphere, and studied of the chemical and physical processes which control gas-to-particle conversion were carried out in the laboratory.

  13. Permeability of cork to gases.

    Science.gov (United States)

    Faria, David P; Fonseca, Ana L; Pereira, Helen; Teodoro, Orlando M N D

    2011-04-27

    The permeability of gases through uncompressed cork was investigated. More than 100 samples were assessed from different plank qualities to provide a picture of the permeability distribution. A novel technique based on a mass spectrometer leak detector was used to directly measure the helium flow through the central area of small disks 10 mm in diameter and 2 mm thick. The permeability for nitrogen, oxygen, and other gases was measured by the pressure rise technique. Boiled and nonboiled cork samples from different sections were evaluated. An asymmetric frequency distribution ranging 3 orders of magnitude (roughly from 1 to 1000 μmol/(cm·atm·day)) for selected samples without macroscopic defects was found, having a peak below 100 μmol/(cm·atm·day). Correlation was found between density and permeability: higher density samples tend to show lower permeability. However, boiled cork showed a mean lower permeability despite having a lower density. The transport mechanism of gases through cork was also examined. Calculations suggest that gases permeate uncompressed cork mainly through small channels between cells under a molecular flow regime. The diameter of such channels was estimated to be in the range of 100 nm, in agreement with the plasmodesmata size in the cork cell walls.

  14. Tear Mediators in Corneal Ectatic Disorders.

    Directory of Open Access Journals (Sweden)

    Dorottya Pásztor

    Full Text Available To compare the concentrations of 11 tear mediators in order to reveal the biochemical difference between pellucid marginal degeneration (PMD and keratoconus (KC.We have designed a cross-sectional study in which patients with corneal ectasia based on slit-lamp biomicroscopy and Pentacam HR (keratometry values (K1, K2, Kmax, astigmatism, minimal radius of curvature (Rmin, corneal thickness (Apex and Min, indices (surface variation, vertical asymmetry, keratoconus, central keratoconus, height asymmetry and decentration were enrolled. Eyes of keratoconic patients were similar to the PMD patients in age and severity (K2, Kmax and Rmin. Non-stimulated tear samples were collected from nine eyes of seven PMD patients, 55 eyes of 55 KC patients and 24 eyes of 24 healthy controls. The mediators' (interleukin -6, -10, chemokine ligand 5, -8, -10, matrix metalloproteinase (MMP -9, -13, tissue inhibitor of metalloproteinases (TIMP-1, tissue plasminogen activator, plasminogen activator inhibitor, nerve growth factor concentrations were measured using Cytometric Bead Array.MMP-9 was the only mediator which presented relevant variances between the two patient groups (p = 0.005. The ratios of MMP-9 and TIMP-1 were 2.45, 0.40 and 0.23 in PMD, KC and the controls, respectively.As far as we are aware, this is the first study that aims to reveal the biochemical differences between PMD and KC. Further studies of biomarkers to investigate the precise role of these mediators need to be defined, and it is important to confirm the observed changes in a larger study to gain further insights into the molecular alterations in PMD.

  15. The relationship between tear severity, fatty infiltration, and muscle atrophy in the supraspinatus.

    Science.gov (United States)

    Barry, Jeffrey J; Lansdown, Drew A; Cheung, Sunny; Feeley, Brian T; Ma, C Benjamin

    2013-01-01

    Fatty infiltration and muscle atrophy have been described as interrelated characteristic changes that occur within the muscles of the rotator cuff after cuff tears, and both are independently associated with poor outcomes after surgical repair. We hypothesize that fatty infiltration and muscle atrophy are two distinct processes independently associated with supraspinatus tears. A retrospective review of 377 patients who underwent shoulder magnetic resonance imaging at one institution was performed. Multivariate analysis was performed based on parameters including age, sex, rotator cuff tear severity, fatty infiltration grade, and muscle atrophy. A total of 116 patients (30.8%) had full-thickness tears of the supraspinatus, 153 (40.6%) had partial thickness tears, and 108 (28.7%) had no evidence of tear. With increasing tear severity, the prevalence of substantial fatty infiltration (grade ≥2) increased: 6.5% of patients with no tears vs 41.4% for complete tears (P tear severity: 36.1% of no tears vs 77.6% of complete tears (P muscle atrophy when taking into account sex, age, and tear severity. Fatty infiltration and muscle atrophy are independently associated processes. Fatty infiltration is also related to increasing age, muscle tear severity, and sex, whereas muscle atrophy is related to increasing age but not tear severity. In patients without rotator cuff tears, fatty infiltration and atrophy prevalence increased independently with increasing age. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  16. From current-driven to neoclassically driven tearing modes.

    Science.gov (United States)

    Reimerdes, H; Sauter, O; Goodman, T; Pochelon, A

    2002-03-11

    In the TCV tokamak, the m/n = 2/1 island is observed in low-density discharges with central electron-cyclotron current drive. The evolution of its width has two distinct growth phases, one of which can be linked to a "conventional" tearing mode driven unstable by the current profile and the other to a neoclassical tearing mode driven by a perturbation of the bootstrap current. The TCV results provide the first clear observation of such a destabilization mechanism and reconcile the theory of conventional and neoclassical tearing modes, which differ only in the dominant driving term.

  17. Experimental observations of the tearing of an electron current sheet

    International Nuclear Information System (INIS)

    Gekelman, W.; Pfister, H.

    1988-01-01

    A neutral magnetic sheet, in which the current is carried mainly by the electrons, is set up in a laboratory plasma. By forcing the current through a thin slot, the ratio of the length to height t of the sheet may be varied; the current is observed to tear when tapprox. >30. The structure of the magnetic islands and their associated currents is fully three dimensional, although a linear two-dimensional theory gives a very good estimate of the tearing mode growth time. Tearing is accompanied by the generation of significant Hall currents, and magnetic disturbances are observed to propagate at the whistler wave speed

  18. Non-linear evolution of double tearing modes in tokamaks

    International Nuclear Information System (INIS)

    Fredrickson, E.; Bell, M.; Budny, R.V.; Synakowski, E.

    1999-01-01

    The delta prime formalism with neoclassical modifications has proven to be a useful tool in the study of tearing modes in high beta, collisionless plasmas. In this paper the formalism developed for the inclusion of neoclassical effects on tearing modes in monotonic q-profile plasmas is extended to plasmas with hollow current profiles and double rational surfaces. First, the classical formalism of tearing modes in the Rutherford regime in low beta plasmas is extended to q profiles with two rational surfaces. Then it is shown that this formalism is readily extended to include neoclassical effects

  19. Tearing modes in tokamaks with lower hybrid current drive

    International Nuclear Information System (INIS)

    Xu, X.Q.

    1990-08-01

    In this paper, the effect of current drive on the tearing modes in the semi-collisional regime is analyzed using the drift-kinetic equation. A collisional operator is developed to model electron parallel conductivity. For the pure tearing modes the linear and quasilinear growth rates in the Rutherford regimes have been found to have roughly the same forms with a modified resistivity as without current drive. One interesting result is the prediction of a new instability. This instability, driven by the current gradient inside the tearing mode layer, is possibly related to MHD behavior observed in these experiments. 9 refs

  20. Threshold condition for nonlinear tearing modes in tokamaks

    International Nuclear Information System (INIS)

    Zabiego, M.F.; Callen, J.D.

    1996-03-01

    Low-mode-number tearing, mode nonlinear evolution is analyzed emphasizing the need for a threshold condition, to account for observations in tokamaks. The discussion is illustrated by two models recently introduced in the literature. The models can be compared with the available data and/or serve as a basis for planning some experiments in order to either test theory (by means of beta-limit scaling laws, as proposed in this paper) or attempt to control undesirable tearing modes. Introducing a threshold condition in the tearing mode stability analysis is found to reveal some bifurcation points and thus domains of intrinsic stability in the island dynamics operational space

  1. Diagnosis of subscapularis lesion in rotator cuff tears

    International Nuclear Information System (INIS)

    Terrier, F.; Wegmueller, H.; Vock, P.; Gerber, C.

    1989-01-01

    In rotator cuff tears, the subscapularis tendon is more often involved than previously suspected, and this lesion is often missed at arthrography. Because preoperative diagnosis is important for planning surgical repair, the authors have evaluated MR imaging and US in the detection of subscapularis tears. Fifteen patients with clinically suspected rotator cuff tears underwent MR imaging and US. Ten of 15 patients were treated surgically, and the other five were treated conservatively. MR imaging was performed with a 1.5-T Signa MR system. T1-weighted spin-echo (SE) and T2-weighted gradient-echo (GE) images were obtained

  2. Quadriceps Strength and Endurance After Posterior Cruciate Ligament Tears Versus Matched Group With Anterior Cruciate Ligament Tears.

    Science.gov (United States)

    Lee, Dae-Hee; Han, Seung-Beom; Lee, Jin-Hyuck; Lee, Seok-Joo; Suh, Dong-Won; Jeong, Hye-Jin

    2015-06-01

    This study was designed to compare the preoperative strengths and endurances of the quadriceps and hamstring muscles in patients with anterior cruciate ligament (ACL) versus posterior cruciate ligament (PCL) tears. Quadriceps and hamstring muscle strength and endurance were compared between 20 prospectively enrolled patients with isolated PCL tears and a retrospective, matched control group of 20 patients with isolated ACL tears. The maximal torque (60°/s) and total work (180°/s) of the quadriceps and hamstring were evaluated with an isokinetic testing device. Total work (1,094.4 ± 505.8 J v 797.5 ± 332.7 J, P = .035) and peak torque (129.9 ± 56.2 N ∙ m v 98.2 ± 37.4 N ∙ m, P = .046) of the quadriceps muscle on the involved side were higher in the PCL tear group than in the ACL tear group. However, there were no significant differences between the PCL tear group and ACL tear group in hamstring muscle strength (45.8 ± 42.3 N ∙ m and 46.0 ± 24.4 N ∙ m, respectively; P = .940) and endurance (429.3 ± 238.9 J and 382.4 ± 256.1 J, respectively; P = .574) on the involved side. The strength and endurance of the quadriceps muscle of the injured limb were greater after PCL tears than after ACL tears. However, there were no significant between-group differences in hamstring muscle strength and endurance on the involved side. Level III, retrospective comparative study. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  3. MR Imaging of a Posterior Root Tear of the Medial Meniscus: Diagnostic Accuracy of Various Tear Configurations and Associated Knee Abnormalities

    International Nuclear Information System (INIS)

    Lee, Hyang Mi; Shim, Jae Chan; Kim, Jin Goo; Lee, Jae Myeong; Nam, Mee Young; Lee, Ghi Jai; Kim, Ho Kyun; Suh, Jung Ho

    2010-01-01

    To evaluate the diagnostic accuracy of the various tear configurations in a medial meniscal posterior horn root tear and assess whether any correlation exists with other associated knee abnormalities in MR imaging. A retrospective review of 146 preoperative knee MR images were performed by one experienced musculoskeletal radiologist. The tear configuration and other abnormalities were evaluated. Sensitivity, specificity, and diagnostic accuracy of each configuration in the medial meniscal posterior horn root tear were calculated. A total of 48 medial meniscal posterior horn root tears including 38 full-thickness radial, 7 partial-thickness radial, and 3 complex tears were confirmed during arthroscopy. Overall, the sensitivity, specificity, and accuracy for the detection of medial meniscal posterior horn root tear were 92% (44/48), 99% (97/98), and 97% (141/146), respectively. For each tear configuration, sensitivity, specificity, and accuracy were 82% (31/38), 97% (105/108), and 93% (136/146) for full-thickness radial tears, respectively, and 43% (3/7), 94% (131/139), and 91% (134/146) for partial-thickness radial tears, respectively. The incidence of degenerative joint disease was 85% (41/48) for the tear group, revealing a strong association. In patients with a root tear and with degenerative joint disease, the incidence of high grade cartilage defects involving the medial femoral condyle was at 80% (33/41), compared to 56% (23/41) for the presence of medial meniscal extrusion. In contrast, a similar comparison of incidence for patients with no root tears but with degenerative joint disease was at 68% (17/25) and 26% (8/31), respectively. MR imaging is very sensitive for the detection of medial meniscal root tears, but has reduced the accuracy with regard to each tear configuration. Medial meniscal root tears showed a strong association with degenerative joint disease. High grade cartilage defects of the medial femoral condyle and medial meniscal extrusions also

  4. MR Imaging of a Posterior Root Tear of the Medial Meniscus: Diagnostic Accuracy of Various Tear Configurations and Associated Knee Abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyang Mi; Shim, Jae Chan; Kim, Jin Goo; Lee, Jae Myeong; Nam, Mee Young; Lee, Ghi Jai; Kim, Ho Kyun; Suh, Jung Ho [Inje University College of Medicine, Seoul Paik Hospital, Seoul (Korea, Republic of)

    2010-11-15

    To evaluate the diagnostic accuracy of the various tear configurations in a medial meniscal posterior horn root tear and assess whether any correlation exists with other associated knee abnormalities in MR imaging. A retrospective review of 146 preoperative knee MR images were performed by one experienced musculoskeletal radiologist. The tear configuration and other abnormalities were evaluated. Sensitivity, specificity, and diagnostic accuracy of each configuration in the medial meniscal posterior horn root tear were calculated. A total of 48 medial meniscal posterior horn root tears including 38 full-thickness radial, 7 partial-thickness radial, and 3 complex tears were confirmed during arthroscopy. Overall, the sensitivity, specificity, and accuracy for the detection of medial meniscal posterior horn root tear were 92% (44/48), 99% (97/98), and 97% (141/146), respectively. For each tear configuration, sensitivity, specificity, and accuracy were 82% (31/38), 97% (105/108), and 93% (136/146) for full-thickness radial tears, respectively, and 43% (3/7), 94% (131/139), and 91% (134/146) for partial-thickness radial tears, respectively. The incidence of degenerative joint disease was 85% (41/48) for the tear group, revealing a strong association. In patients with a root tear and with degenerative joint disease, the incidence of high grade cartilage defects involving the medial femoral condyle was at 80% (33/41), compared to 56% (23/41) for the presence of medial meniscal extrusion. In contrast, a similar comparison of incidence for patients with no root tears but with degenerative joint disease was at 68% (17/25) and 26% (8/31), respectively. MR imaging is very sensitive for the detection of medial meniscal root tears, but has reduced the accuracy with regard to each tear configuration. Medial meniscal root tears showed a strong association with degenerative joint disease. High grade cartilage defects of the medial femoral condyle and medial meniscal extrusions also

  5. Sonographic Visualization of the Rotator Cable in Patients With Symptomatic Full-Thickness Rotator Cuff Tears: Correlation With Tear Size, Muscular Fatty Infiltration and Atrophy, and Functional Outcome.

    Science.gov (United States)

    Bureau, Nathalie J; Blain-Paré, Etienne; Tétreault, Patrice; Rouleau, Dominique M; Hagemeister, Nicola

    2016-09-01

    To assess the prevalence of sonographic visualization of the rotator cable in patients with symptomatic full-thickness rotator cuff tears and asymptomatic controls and to correlate rotator cable visualization with tear size, muscular fatty infiltration and atrophy, and the functional outcome in the patients with rotator cuff tears. Fifty-seven patients with rotator cuff tears and 30 asymptomatic volunteers underwent shoulder sonography for prospective assessment of the rotator cable and rotator cuff tear and responded to 2 functional outcome questionnaires (shortened Disabilities of the Arm, Shoulder, and Hand [QuickDASH] and Constant). In the patients with rotator cuff tears, appropriate tests were used to correlate rotator cable visualization with the tear size, functional outcome, muscular fatty infiltration, and atrophy. The patients with rotator cuff tears included 25 women and 32 men (mean age,57 years; range, 39-67 years), and the volunteers included 13 women and 17 men (mean age, 56 years; range, 35-64 years). The rotator cable was identified in 77% (23 of 30) of controls and 23% (13 of 57) of patients with rotator cuff tears. In the patients, nonvisualization of the rotator cable correlated with larger tears (P tears than asymptomatic controls and was associated with a larger tear size and greater supraspinatus fatty infiltration and atrophy. Diligent assessment of the supraspinatus muscle should be done in patients with rotator cuff tears without a visible rotator cable, as the integrity of these anatomic structures may be interdependent.

  6. Anterior versus posterior, and rim-rent rotator cuff tears: prevalence and MR sensitivity

    International Nuclear Information System (INIS)

    Tuite, M.J.; Turnbull, J.R.; Orwin, J.F.

    1998-01-01

    Purpose. To determine the relative distribution of the locations of rotator cuff tears, and the sensitivity of anterior versus posterior tears on MR images. Patients and methods. We identified 110 consecutive patients who had a shoulder MR and either a partial-thickness or a small full-thickness rotator cuff tear diagnosed at arthroscopy. MR sensitivity and patient age were compared between patients with tears in the anterior and posterior halves of the cuff. In addition, in patients with partial tears less than 2 cm in diameter, an age comparison between those with tears in the critical zone and those with articular surface tears adjacent to the bony insertion (rim-rent tear) was performed. Results. The tear was centered in the anterior half of the rotator cuff in 79% of the patients younger than 36 years old, and in 89% of the patients 36 years old and over. The average age of the patients with tears in the anterior half (44 years) was not significantly different from the average age of those with posterior tears (40 years). The sensitivity of MR for anterior tears was 0.69, and for posterior tears it was 0.56. Five of the nine rim-rent tears (0.56) were interpreted correctly on the original MR report; two of the other tears were misinterpreted as intratendinous fluid but were diagnosable in retrospect. Conclusion. Even in patients less than 36 years old, most partial and small full-thickness rotator cuff tears are centered in the anterior half of the supraspinatus. Although our figure for MR sensitivity for these tears is lower than in recent articles, we found no significant difference between the sensitivity of MR for diagnosing posterior tears versus tears in the anterior half of the supraspinatus tendon. Rim-rent tears can be mistaken for intratendinous signal, and should be carefully looked for in younger patients with shoulder pain. (orig.)

  7. The Effect of Polar Lipids on Tear Film Dynamics

    KAUST Repository

    Aydemir, E.

    2010-06-17

    In this paper, we present a mathematical model describing the effect of polar lipids, excreted by glands in the eyelid and present on the surface of the tear film, on the evolution of a pre-corneal tear film. We aim to explain the interesting experimentally observed phenomenon that the tear film continues to move upward even after the upper eyelid has become stationary. The polar lipid is an insoluble surface species that locally alters the surface tension of the tear film. In the lubrication limit, the model reduces to two coupled non-linear partial differential equations for the film thickness and the concentration of lipid. We solve the system numerically and observe that increasing the concentration of the lipid increases the flow of liquid up the eye. We further exploit the size of the parameters in the problem to explain the initial evolution of the system. © 2010 Society for Mathematical Biology.

  8. the effect of acetaminophen (paracetamol ) on tear production abstract

    African Journals Online (AJOL)

    LIVINGSTON

    cox-1 and cox-2 has long been known to be the mechanism of action ... effects typical of NSAIDS . Chronic excessive alcohol consumption can ... The effect of acetaminophen (paracetamol ) on the tear production of 100 young healthy subjects ...

  9. Early Vitrectomy for Vitreous Hemorrhage Associated With Retinal Tears

    NARCIS (Netherlands)

    Tan, H. Stevie; Mura, Marco; Bijl, Heico M.

    2010-01-01

    PURPOSE: To evaluate outcome of early surgery in vitreous hemorrhage, presumably associated with retinal tears. DESIGN: Retrospective, noncomparative interventional case series. METHODS: We included 40 consecutive cases in 39 patients treated with early vitrectomy for vitreous hemorrhage. Main

  10. Tearing mode dynamics and sawtooth oscillation in Hall-MHD

    Science.gov (United States)

    Ma, Zhiwei; Zhang, Wei; Wang, Sheng

    2017-10-01

    Tearing mode instability is one of the most important dynamic processes in space and laboratory plasmas. Hall effects, resulted from the decoupling of electron and ion motions, could cause the fast development and perturbation structure rotation of the tearing mode and become non-negligible. We independently developed high accuracy nonlinear MHD code (CLT) to study Hall effects on the dynamic evolution of tearing modes with Tokamak geometries. It is found that the rotation frequency of the mode in the electron diamagnetic direction is in a good agreement with analytical prediction. The linear growth rate increases with increase of the ion inertial length, which is contradictory to analytical solution in the slab geometry. We further find that the self-consistently generated rotation largely alters the dynamic behavior of the double tearing mode and the sawtooth oscillation. National Magnetic Confinement Fusion Science Program of China under Grant No. 2013GB104004 and 2013GB111004.

  11. Progression from calcifying tendinitis to rotator cuff tear

    Energy Technology Data Exchange (ETDEWEB)

    Gotoh, Masafumi; Higuchi, Fujio; Suzuki, Ritsu; Yamanaka, Kensuke [Department of Orthopaedic Surgery, Medical Center of Kurume University, 155-1 Kokubu-machi, Kurume City, Fukuoka 839-0862 (Japan)

    2003-02-01

    This report documents the clinical, radiographic and histologic findings in a 46-year-old man with calcifying tendinitis in his left shoulder which progressed to rotator cuff tear. The patient had a 1-year history of repeated calcifying tendinitis before being referred to our hospital. On the initial visit, radiographs and magnetic resonance imaging (MRI) revealed calcium deposition localized in the supraspinatus tendon without apparent tear. Three months after the first visit, MRI revealed a partial-thickness rotator cuff tear at the site of calcium deposition. Surgical and histologic findings demonstrated that calcium deposition was the cause of cuff rupture. To our knowledge, based on a review of the English literature, this is the first case report in which the progression from calcifying tendinitis to rotator cuff tear has been serially observed. (orig.)

  12. Progression from calcifying tendinitis to rotator cuff tear

    International Nuclear Information System (INIS)

    Gotoh, Masafumi; Higuchi, Fujio; Suzuki, Ritsu; Yamanaka, Kensuke

    2003-01-01

    This report documents the clinical, radiographic and histologic findings in a 46-year-old man with calcifying tendinitis in his left shoulder which progressed to rotator cuff tear. The patient had a 1-year history of repeated calcifying tendinitis before being referred to our hospital. On the initial visit, radiographs and magnetic resonance imaging (MRI) revealed calcium deposition localized in the supraspinatus tendon without apparent tear. Three months after the first visit, MRI revealed a partial-thickness rotator cuff tear at the site of calcium deposition. Surgical and histologic findings demonstrated that calcium deposition was the cause of cuff rupture. To our knowledge, based on a review of the English literature, this is the first case report in which the progression from calcifying tendinitis to rotator cuff tear has been serially observed. (orig.)

  13. Isolated medial meniscal tear in a Border Collie.

    Science.gov (United States)

    Ridge, P A

    2006-01-01

    A three-year-old, female Border Collie was successfully treated for an isolated, torn, medial meniscus by arthroscopic meniscal tear resection. The dog returned to agility competition without recurrence of lameness.

  14. Peroneus longus tears associated with pathology of the os peroneum.

    Science.gov (United States)

    Stockton, Kristopher G; Brodsky, James W

    2014-04-01

    There is a range of different types of tears and pathology of the peroneal tendons. One of the least common types is the tear of the peroneus longus associated with fracture, enlargement, or entrapment at the cuboid tunnel of the os peroneum. The purpose of this study was to evaluate the pathologic patterns of these uncommon peroneal tendon tears, to review the treatment, and to report the patient outcomes following treatment with excision of the os peroneum, debridement, and tenodesis of the peroneus longus to the peroneus brevis. A 5-year retrospective review of all patients with peroneal tendon tears identified 12 patients operatively treated for peroneus longus tendon tears with associated pathology of the os peroneum, and in whom there was a viable peroneus brevis. All patients were treated with an operative procedure consisting of excision of the os peroneum, debridement, and tenodesis of the peroneus longus to the peroneus brevis. Mean age was 51.5 (range, 33 to 73) years, including 7 males and 5 females. Operative and radiographic records were reviewed to characterize the nature of the peroneus longus tears and associated pathology. Preoperative and postoperative AOFAS hindfoot, SF-36 questionnaires, and Visual Analog Scale (VAS) pain scores were compiled and patient records were reviewed for complications. Mean follow-up after surgery was 63.3 (range, 12 to 114) months. All of the patients had an os peroneum associated with a complex, irreparable tear of the peroneus longus tendon. The peroneus longus was typically enlarged, fibrotic, and adhered to the surrounding tissues. In 8 patients, the peroneus longus tendon tear was associated with a fracture of the os peroneum, and in 4 patients with an enlarged and entrapped os peroneum which prevented movement at the cuboid tunnel. Of the 12 patients, 9 had partial tears of the peroneus brevis, which were treated with debridement and suture repair. AOFAS hindfoot scores increased from a preoperative mean of 61

  15. Comparison of Medial and Lateral Meniscus Root Tears.

    Directory of Open Access Journals (Sweden)

    Ji Hyun Koo

    Full Text Available The meniscus root plays an essential role in maintaining the circumferential hoop tension and preventing meniscal displacement. Studies on meniscus root tears have investigated the relationship of osteoarthritis and an anterior cruciate ligament tear. However, few studies have directly compared the medial and lateral root tears. To assess the prevalence of meniscal extrusion and its relationship with clinical features in medial and lateral meniscus root tears, we performed a retrospective review of the magnetic resonance imaging (MRI results of 42 knee patients who had meniscus posterior horn root tears and who had undergone arthroscopic operations. The presence of meniscal extrusion was evaluated and the exact extent was measured from the tibial margin. The results were correlated with arthroscopic findings. Clinical features including patients' ages, joint abnormalities, and previous trauma histories were evaluated. Twenty-two patients had medial meniscus root tears (MMRTs and twenty patients had lateral meniscus root tears (LMRTs. Meniscal extrusion was present in 18 MMRT patients and one LMRT patient. The mean extent of extrusion was 4.2mm (range, 0.6 to 7.8 in the MMRT group and 0.9mm (range, -1.9 to 3.4 in the LMRT group. Five patients with MMRT had a history of trauma, while 19 patients with LMRT had a history of trauma. Three patients with MMRT had anterior cruciate ligament (ACL tears, while 19 patients with LMRT had ACL tears. The mean age of the patients was 52 years (range: 29-71 years and 30 years (range: 14-62 years in the MMRT and LMRT group, respectively. There was a significant correlation between a MMRT and meniscal extrusion (p<0.0001, and between an ACL tear and LMRT (p<0.0001. A history of trauma was significantly common in LMRT (p<0.0001. LMRT patients were significantly younger than MMRT patients (p<0.0001. Kellgren-Lawrence (K-L grade differed significantly between MMRT and LMRT group (p<0.0001. Meniscal extrusion is

  16. MR imaging of delamination tears of the rotator cuff tendons

    International Nuclear Information System (INIS)

    Walz, Daniel M.; Chen, Steven; Miller, Theodore T.; Hofman, Josh

    2007-01-01

    The objective was to describe the imaging appearances and location of delamination tears of the rotator cuff tendons on non-contrast conventional MR imaging. This study was reviewed and approved by our Institutional Review Board. The reports of 548 consecutive MR examinations of the shoulder were reviewed, looking for mention or description of delamination tears of the rotator cuff. The images of the identified cases were then reviewed by two radiologists to confirm the findings. Correlation with surgical and arthroscopic information was then performed. Delamination tears were defined as horizontal retraction of either the bursal or articular surface of the tendon, manifest as thickening of the torn retracted edge, and/or interstitial splitting of the tendon, manifest as fluid-like high signal intensity on fat-suppressed T2-weighted oblique coronal images. Fourteen cases of delamination tears were identified in 13 patients. Ten of the cases involved the supraspinatus tendon, all with articular surface involvement. Nine of these supraspinatus cases were isolated tears and one occurred as part of a full thickness tear. All 10 of these supraspinatus cases showed medial retraction of the articular surface of the tendon, with thickening of the retracted edge, and 5 of the 10 had a demonstrable horizontal cleft in the interstitium. Four cases involved the subscapularis tendon, with articular surface disruption in three and pure interstitial delamination in one. Medial subluxation of the tendon of the long head of the biceps was present in all four cases. No delamination tears occurred on the bursal surface. Only three of the 14 shoulders underwent surgical repair with one confirmation of supraspinatus delamination, one confirmation of a subscapularis tear that had become a full thickness tear 10 months after initial imaging and another interstitial subscapularis delamination that was not identified arthroscopically. Delamination tears occur most often in the

  17. MR imaging of delamination tears of the rotator cuff tendons

    Energy Technology Data Exchange (ETDEWEB)

    Walz, Daniel M.; Chen, Steven [North Shore University Hospital, Department of Radiology, Manhasset, NY (United States); Miller, Theodore T. [Hospital for Special Surgery, Department of Radiology and Imaging, New York, NY (United States); Hofman, Josh [Long Island Jewish Medical Center, New Hyde Park, NY (United States)

    2007-05-15

    The objective was to describe the imaging appearances and location of delamination tears of the rotator cuff tendons on non-contrast conventional MR imaging. This study was reviewed and approved by our Institutional Review Board. The reports of 548 consecutive MR examinations of the shoulder were reviewed, looking for mention or description of delamination tears of the rotator cuff. The images of the identified cases were then reviewed by two radiologists to confirm the findings. Correlation with surgical and arthroscopic information was then performed. Delamination tears were defined as horizontal retraction of either the bursal or articular surface of the tendon, manifest as thickening of the torn retracted edge, and/or interstitial splitting of the tendon, manifest as fluid-like high signal intensity on fat-suppressed T2-weighted oblique coronal images. Fourteen cases of delamination tears were identified in 13 patients. Ten of the cases involved the supraspinatus tendon, all with articular surface involvement. Nine of these supraspinatus cases were isolated tears and one occurred as part of a full thickness tear. All 10 of these supraspinatus cases showed medial retraction of the articular surface of the tendon, with thickening of the retracted edge, and 5 of the 10 had a demonstrable horizontal cleft in the interstitium. Four cases involved the subscapularis tendon, with articular surface disruption in three and pure interstitial delamination in one. Medial subluxation of the tendon of the long head of the biceps was present in all four cases. No delamination tears occurred on the bursal surface. Only three of the 14 shoulders underwent surgical repair with one confirmation of supraspinatus delamination, one confirmation of a subscapularis tear that had become a full thickness tear 10 months after initial imaging and another interstitial subscapularis delamination that was not identified arthroscopically. Delamination tears occur most often in the

  18. Soliton Gases and Generalized Hydrodynamics

    Science.gov (United States)

    Doyon, Benjamin; Yoshimura, Takato; Caux, Jean-Sébastien

    2018-01-01

    We show that the equations of generalized hydrodynamics (GHD), a hydrodynamic theory for integrable quantum systems at the Euler scale, emerge in full generality in a family of classical gases, which generalize the gas of hard rods. In this family, the particles, upon colliding, jump forward or backward by a distance that depends on their velocities, reminiscent of classical soliton scattering. This provides a "molecular dynamics" for GHD: a numerical solver which is efficient, flexible, and which applies to the presence of external force fields. GHD also describes the hydrodynamics of classical soliton gases. We identify the GHD of any quantum model with that of the gas of its solitonlike wave packets, thus providing a remarkable quantum-classical equivalence. The theory is directly applicable, for instance, to integrable quantum chains and to the Lieb-Liniger model realized in cold-atom experiments.

  19. Noble Gases in Lakes and Ground Waters

    OpenAIRE

    Kipfer, Rolf; Aeschbach-Hertig, Werner; Peeters, Frank; Stute, Marvin

    2002-01-01

    In contrast to most other fields of noble gas geochemistry that mostly regard atmospheric noble gases as 'contamination,' air-derived noble gases make up the far largest and hence most important contribution to the noble gas abundance in meteoric waters, such as lakes and ground waters. Atmospheric noble gases enter the meteoric water cycle by gas partitioning during air / water exchange with the atmosphere. In lakes and oceans noble gases are exchanged with the free atmosphere at the surface...

  20. Threshold condition for nonlinear tearing modes in tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Zabiego, M.F. [Association Euratom-CEA, Centre d`Etudes de Cadarache, 13 - Saint-Paul-lez-Durance (France). Dept. de Recherches sur la Fusion Controlee; Callen, J.D. [Wisconsin Univ., Madison, WI (United States). Dept. of Nuclear Engineering and Engineering Physics

    1996-04-01

    Low-mode-number tearing mode nonlinear evolution is analyzed emphasizing the need for a threshold condition, to account for observations in tokamaks. The discussion is illustrated by two models recently introduced in the literature. Introducing a threshold condition in the tearing mode stability analysis is found to reveal some bifurcation points and thus domains of intrinsic stability in the island dynamics operational space. (author). 19 refs.

  1. Predictive MRI correlates of lesser metatarsophalangeal joint plantar plate tear

    Energy Technology Data Exchange (ETDEWEB)

    Umans, Rachel L. [Cornell University Medical College, New York, NY (United States); Umans, Benjamin D. [Harvard University, Cambridge, MA (United States); Umans, Hilary [Albert Einstein College of Medicine, Bronx, NY (United States); Lenox Hill Radiology and Imaging Associates, New York, NY (United States); Elsinger, Elisabeth [Albert Einstein College of Medicine, Bronx, NY (United States); Montefiore Medical Center, Bronx, NY (United States)

    2016-07-15

    To identify correlated signs on non-enhanced MRI that might improve diagnostic detection of plantar plate (PP) tear. We performed an IRB-approved, HIPAA-compliant retrospective analysis of 100 non-contrast MRI (50 PP tear, 50 controls). All were anonymized, randomized, and reviewed; 20 were duplicated to assess consistency. One musculoskeletal radiologist evaluated qualitative variables. A trained non-physician performed measurements. Consistency and concordance were assessed. Pearson's Chi-square test was used to test the correlation between qualitative findings and PP tear status. Correlation between measurements and PP status was assessed using t tests and Wilcoxon's rank-sum test (p values < 0.05 considered significant). Classification and regression trees were utilized to identify attributes that, taken together, would consistently distinguish PP tear from controls. Quantitative measurements were highly reproducible (concordance 0.88-0.99). Elevated 2nd MT protrusion, lesser MT supination and rotational divergence of >45 between the 1st-2nd MT axis correlated with PP tear. Pericapsular soft tissue thickening correlated most strongly with PP tear, correctly classifying 95 % of cases and controls. Excluding pericapsular soft tissue thickening, sequential assessment of 2nd toe enthesitis, 2nd flexor tendon subluxation, and splaying of the second and third toes accurately classified PP status in 92 %. Pericapsular soft tissue thickening most strongly correlated with PP tear. For cases in which it might be difficult to distinguish pericapsular fibrosis from neuroma, sequential assessment of 2nd toe enthesitis, flexor tendon subluxation and splaying of the 2nd and 3rd toe is most helpful for optimizing accurate diagnosis of PP tear. (orig.)

  2. Review of tearing mode stabilization by RF power in tokamaks

    International Nuclear Information System (INIS)

    Giruzzi, G.; Zabiego, M.; Zohm, H.

    1999-01-01

    Control of tearing modes by means of heating and current drive inside the magnetic islands is one of the most important applications of RF power in tokamak reactors. The theoretical basis of this concept is reviewed, focusing on aspects related to RF-plasma interaction. Applications to the stabilization of neoclassical tearing modes in ITER by Electron Cyclotron Current Drive are presented to illustrate the basic physical dependences. The most significant experimental results and prospects for future applications are also discussed

  3. Saturated tearing modes in tokamaks. Renewal proposal, progress report

    International Nuclear Information System (INIS)

    Bateman, G.

    1984-01-01

    We have completed a computer code (GTOR) implementing our quasilinear method for determining saturated tearing mode magnetic island widths in axisymmetric toroidal plasmas. With this code we have surveyed the effect of current profile, aspect ratio and plasma elongation on saturated tearing modes. Current peaking within the islands is found to have a particularly large effect. In support of this research, we have developed a direct method for computing Hamada coordinates from harmonics of the inverse Grad-Shafranov equation

  4. Threshold condition for nonlinear tearing modes in tokamaks

    International Nuclear Information System (INIS)

    Zabiego, M.F.; Callen, J.D.

    1996-04-01

    Low-mode-number tearing mode nonlinear evolution is analyzed emphasizing the need for a threshold condition, to account for observations in tokamaks. The discussion is illustrated by two models recently introduced in the literature. Introducing a threshold condition in the tearing mode stability analysis is found to reveal some bifurcation points and thus domains of intrinsic stability in the island dynamics operational space. (author)

  5. Centrifugal separation of mixture gases

    International Nuclear Information System (INIS)

    Zhou, M.S.; Chen, W.N.; Yin, Y.T.

    2008-01-01

    An attempt for single centrifugal separation of mixtures with different molecular formula was presented in this paper. The mixtures of SF 6 and CCl 3 F, and SF 6 and CCl 4 were chosen as the processing gases, which were prepared in three mass ratios, 0.5, 0.8 and 0.2, respectively. The separating characteristics such as the overall separation factors and the variation of cuts were studied. (author)

  6. Readability of Online Sources Regarding Meniscal Tears.

    Science.gov (United States)

    Hodax, Jonathan D; Baird, Grayson L; McBride, Trevor; Owens, Brett D

    2017-09-01

    Meniscal injuries are extremely common, with an incidence of 8.3 per 1,000 person/years in young, active individuals. Patients often turn to the internet to glean information about their injuries, and even to guide decision making about treatment. Much research has been done demonstrating that a reading level of eighth grade or lower is appropriate for accurately communicating written information to patients, yet medical practitioners often fail to meet this requirement. To better examine the information patients receive about meniscal injuries, we set out to evaluate the reading level and content of three commonly used search terms on the three search engines with the largest market share. The authors examined the keywords "meniscus tear," "meniscus tear treatment," and "knee pain meniscus" on the three highest market share search engines. The top 10 results from each search were included, and redundancies identified. Unique Web sites were evaluated for source, word count, reading level, and content including advertisements, diagrams, photographs, nonoperative and operative options, and accurate medical information. A total of 23 unique Web sites were identified in our search, including 13 public education sources, 6 academic institutions, and 4 private physicians/groups. Average grade levels of articles ranged from 9.4 to 14.2 (mean, 11.14; standard deviation [SD] 1.46), and Flesch-Kincaid reading ease scores ranged from 23.9 to 68.7 (mean, 55.31; SD, 10.11). Pages from public sources required the highest level of readability (11.6, 95% confidence interval [CI]: 9.8-13.2), which was significantly higher than private (11.0, 95% CI: 9.3, 12.7]) and academic (10.9, 95% CI: 8.9-12.9), p  = 0.007 and p  = 0.002, respectively. Further efforts to make appropriate health information available to patients are needed. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  7. Medialized repair for retracted rotator cuff tears.

    Science.gov (United States)

    Kim, Young-Kyu; Jung, Kyu-Hak; Won, Jun-Sung; Cho, Seung-Hyun

    2017-08-01

    The purpose of this study was to evaluate the functional outcomes of medialized rotator cuff repair and the continuity of repaired tendon in chronic retracted rotator cuff tears. Thirty-five consecutive patients were selected from 153 cases that underwent arthroscopic rotator cuff repair for more than medium-sized posterosuperior rotator cuff tears between July 2009 and July 2012 performed with the medialized repair. All cases were available for at least 2 years of postoperative follow-up. The visual analog scale of pain, muscle strength, Constant score, American Shoulder and Elbow Surgeons (ASES) score, and University of California-Los Angeles score were evaluated. At the final follow-up, all clinical outcomes were significantly improved. The visual analog scale score for pain improved from 6 ± 1 preoperatively to 2 ± 1 postoperatively. The range of motion increased from preoperatively to postoperatively: active forward elevation, from 134° ± 49° to 150° ± 16°; active external rotation at the side, from 47° ± 15° to 55° ± 10°; and active internal rotation, from L3 to L1. The shoulder score also improved: Constant score, from 53.5 ± 16.7 to 79 ± 10; American Shoulder and Elbow Surgeons score, from 51 ± 15 to 82 ± 8; and University of California-Los Angeles score, from 14 ± 4 to 28 ± 4. The retear cases at the final follow-up were 6 (17%). Medialized repair may be useful in cases in which anatomic bone-to-tendon repair would be difficult because of the excessive tension of the repaired tendon and a torn tendon that does not reach the anatomic insertion. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  8. Landfill gases and some effects on vegetation

    Science.gov (United States)

    Franklin B. Flower; Ida A. Leone; Edward F. Gilman; John J. Arthur

    1977-01-01

    Gases moving from refuse landfills through soil were studied in New Jersey. The gases, products of anaerobic decomposition of organic matter in the refuse, caused injury and death of peach trees, ornamentals, and commercial farm crops, and create possible hazards to life and property because of the entrance of combustible gases into residences. Remedial measures are...

  9. MRI diagnosis in meniscal tears: a Meta analysis

    International Nuclear Information System (INIS)

    Liu Xiaosheng; Xu Jianrong; Hua Jia; Wang Baisong

    2007-01-01

    Objective: To perform a Meta-analysis to evaluate the overall diagnostic value of magnetic resonance imaging (MRI) in patients with suspected meniscal tears. Methods: All the papers concerning the diagnosis of meniscal tears using MRI in both English and Chinese published from 1998 to 2004 had been searched and reviewed, and the studies with the arthroscopy as the gold standard were adopted as eligible. Statistical analysis was performed employing SAS 8.0. Heterogeneity of the included articles was tested, which was used to select proper effect model to calculate pooled weighted sensitivity, specificity and accuracy. Summary receiver operating characteristic (SROC) analyses were performed for tears of both menisci. Finally, subgroup analysis on magnetic field strength was performed. Results: Totally 11 studies were met the inclusion criteria with a total of 1221 patients. The pooled indexes of diagnostic performance and SROC demonstrated a high discriminatory power for detecting tears of the medial and lateral menisci. The value of TPR * for medial and lateral menisci showed no significant difference (0.90, 0.86, respectively, Z=0.11, P>0.05). Subgroup analysis demonstrated no statistically significant difference on diagnostic performance for various magnetic field strength (P>0.05). Conclusion: MRI is a highly accurate diagnostic tool for detecting tears of the medial and lateral menisci. At present, there is no evidence to ascertain that higher magnetic field strength improves discriminatory power for meniscal tears. (authors)

  10. Meniscal Tear Film Fluid Dynamics Near Marx’s Line

    KAUST Repository

    Zubkov, V. S.

    2013-07-03

    Extensive studies have explored the dynamics of the ocular surface fluid, though theoretical investigations are typically limited to the use of the lubrication approximation, which is not guaranteed to be uniformly valid a-priori throughout the tear meniscus. However, resolving tear film behaviour within the meniscus and especially its apices is required to characterise the flow dynamics where the tear film is especially thin, and thus most susceptible to evaporatively induced hyperosmolarity and subsequent epithelial damage. Hence, we have explored the accuracy of the standard lubrication approximation for the tear film by explicit comparisons with the 2D Navier-Stokes model, considering both stationary and moving eyelids. Our results demonstrate that the lubrication model is qualitatively accurate except in the vicinity of the eyelids. In particular, and in contrast to lubrication theory, the solution of the full Navier-Stokes equations predict a distinct absence of fluid flow, and thus convective mixing in the region adjacent to the tear film contact line. These observations not only support emergent hypotheses concerning the formation of Marx\\'s line, a region of epithelial cell staining adjacent to the contact line on the eyelid, but also enhance our understanding of the pathophysiological consequences of the flow profile near the tear film contact line. © 2013 Society for Mathematical Biology.

  11. [Evaluation of chemokines in tears of patients with infectious keratitis].

    Science.gov (United States)

    Hori, Shinsuke; Shoji, Jun; Inada, Noriko; Sawa, Mitsuru

    2013-02-01

    To investigate the chemokine profile in tears of patients with infectious keratitis. Subjects were 32 eyes of 16 patients with infectious keratitis and 5 eyes of 5 healthy volunteers as a control. The patients with infectious keratitis were classified into two groups of eyes: 10 with bacterial keratitis and 6 with Acanthamoeba keratitis. Tear fluid was obtained from both eyes of the patients with infectious keratitis and from the right eyes of the control subjects using filter paper. Chemokine concentration (unit: Odu/mm2) and its profile in tears was analyzed using an antibody-array. In terms of chemokine profile in the bacterial keratitis group, the expression volume of interleukin-8 (IL-8) and monocyte chemoattractant protein-1 (MCP-1) in the diseased eyes was significantly higher than in the healthy eyes (p tears of the Acanthamoeba keratitis group. Regarding the chemokine ratio, the IL-8/MEC ratio in the diseased eyes of the Pseudomonas keratitis group and the MCP-1/IL-8 in the diseased eyes of the Acanthamoeba keratitis group showed a significantly high level (p tears of infectious keratitis patients is useful as a clinical tear laboratory test to interpret the pathologic condition of infectious keratitis

  12. Artificially modified collagen fibril orientation affects leather tear strength.

    Science.gov (United States)

    Kelly, Susyn J; Wells, Hannah C; Sizeland, Katie H; Kirby, Nigel; Edmonds, Richard L; Ryan, Tim; Hawley, Adrian; Mudie, Stephen; Haverkamp, Richard G

    2018-07-01

    Ovine leather has around half the tear strength of bovine leather and is therefore not suitable for high-value applications such as shoes. Tear strength has been correlated with the natural collagen fibril alignment (orientation index, OI). It is hypothesized that it could be possible to artificially increase the OI of the collagen fibrils and that an artificial increase in OI could increase tear strength. Ovine skins, after pickling and bating, were strained biaxially during chrome tanning. The strain ranged from 2 to 15% of the initial sample length, either uniformly in both directions by 10% or with 3% in one direction and 15% in the other. Once tanned, the leather tear strengths were measured and the collagen fibril orientation was measured using synchrotron-based small-angle X-ray scattering. The OI increased as a result of strain during tanning from 0.48 to 0.79 (P = 0.001) measured edge-on and the thickness-normalized tear strength increased from 27 to 43 N mm -1 (P leather was strained 10% in two orthogonal directions. This is evidence to support a causal relationship between high OI (measured edge-on), highly influenced by thickness, and tear strength. It also provides a method to produce stronger leather. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  13. On tear film breakup (TBU): dynamics and imaging.

    Science.gov (United States)

    Braun, Richard J; Driscoll, Tobin A; Begley, Carolyn G; King-Smith, P Ewen; Siddique, Javed I

    2018-06-13

    We report the results of some recent experiments to visualize tear film dynamics. We then study a mathematical model for tear film thinning and tear film breakup (TBU), a term from the ocular surface literature. The thinning is driven by an imposed tear film thinning rate which is input from in vivo measurements. Solutes representing osmolarity and fluorescein are included in the model. Osmolarity causes osmosis from the model ocular surface, and the fluorescein is used to compute the intensity corresponding closely to in vivo observations. The imposed thinning can be either one-dimensional or axisymmetric, leading to streaks or spots of TBU, respectively. For a spatially-uniform (flat) film, osmosis would cease thinning and balance mass lost due to evaporation; for these space-dependent evaporation profiles TBU does occur because osmolarity diffuses out of the TBU into the surrounding tear film, in agreement with previous results. The intensity pattern predicted based on the fluorescein concentration is compared with the computed thickness profiles; this comparison is important for interpreting in vivo observations. The non-dimensionalization introduced leads to insight about the relative importance of the competing processes; it leads to a classification of large vs small TBU regions in which different physical effects are dominant. Many regions of TBU may be considered small, revealing that the flow inside the film has an appreciable influence on fluorescence imaging of the tear film.

  14. Comparison of non-invasive tear film stability measurement techniques.

    Science.gov (United States)

    Wang, Michael Tm; Murphy, Paul J; Blades, Kenneth J; Craig, Jennifer P

    2018-01-01

    Measurement of tear film stability is commonly used to give an indication of tear film quality but a number of non-invasive techniques exists within the clinical setting. This study sought to compare three non-invasive tear film stability measurement techniques: instrument-mounted wide-field white light clinical interferometry, instrument-mounted keratoscopy and hand-held keratoscopy. Twenty-two subjects were recruited in a prospective, randomised, masked, cross-over study. Tear film break-up or thinning time was measured non-invasively by independent experienced examiners, with each of the three devices, in a randomised order, within an hour. Significant correlation was observed between instrument-mounted interferometric and keratoscopic measurements (p 0.05). Tear film stability values obtained from the hand-held device were significantly shorter and demonstrated narrower spread than the other two instruments (all p 0.05). Good clinical agreement exists between the instrument-mounted interferometric and keratoscopic measurements but not between the hand-held device and either of the instrument-mounted techniques. The results highlight the importance of specifying the instrument employed to record non-invasive tear film stability. © 2017 Optometry Australia.

  15. Determination of Ductile Tearing Resistance Curve in Weld Joints

    International Nuclear Information System (INIS)

    Marie, S.; Gilles, P.; Ould, P.

    2010-01-01

    Steels present in the ductile domain a tearing resistance which increase with the crack propagation up to the failure. This ductile tearing resistance is in general characterised with curves giving the variation of a global parameter (opening displacement at the crack tip delta, integral J) versus the crack extension Delta a. These global approaches depend more or less on the specimen geometry and on the type of the imposed loading. Local approaches based on the description of the ductile tearing mechanisms provide reliable solution to the transferability problem (from the lab specimen to the component) but are complex and costly to use and are not codified. These problems get worse in the case of a weld joint where no standard is available for the measurement of their ductile tearing resistance. But the welded joints are often the weak point of the structure because of greater risk of defects, the heterogeneity of the microstructure of the weld, deformation along the interface between two materials with different yield stress (mismatch).... After briefly recalling the problems of transferability of the ductile tearing resistance curves obtained on lab specimen to the case of components, this article identifies the factors complicating the determination of the toughness in the welded joints and gives recommendations for the experimental determination of ductile tearing resistance curves of welded joints

  16. Epidemiology, natural history, and indications for treatment of rotator cuff tears.

    Science.gov (United States)

    Tashjian, Robert Z

    2012-10-01

    The etiology of rotator cuff disease is likely multifactorial, including age-related degeneration and microtrauma and macrotrauma. The incidence of rotator cuff tears increases with aging with more than half of individuals in their 80s having a rotator cuff tear. Smoking, hypercholesterolemia, and genetics have all been shown to influence the development of rotator cuff tearing. Substantial full-thickness rotator cuff tears, in general, progress and enlarge with time. Pain, or worsening pain, usually signals tear progression in both asymptomatic and symptomatic tears and should warrant further investigation if the tear is treated conservatively. Larger (>1-1.5 cm) symptomatic full-thickness cuff tears have a high rate of tear progression and, therefore, should be considered for earlier surgical repair in younger patients if the tear is reparable and there is limited muscle degeneration to avoid irreversible changes to the cuff, including tear enlargement and degenerative muscle changes. Smaller symptomatic full-thickness tears have been shown to have a slower rate of progression, similar to partial-thickness tears, and can be considered for initial nonoperative treatment due to the limited risk for rapid tear progression. In both small full-thickness tears and partial-thickness tears, increasing pain should alert physicians to obtain further imaging as it can signal tear progression. Natural history data, along with information on factors affecting healing after rotator cuff repair, can help guide surgeons in making appropriate decisions regarding the treatment of rotator cuff tears. The management of rotator cuff tears should be considered in the context of the risks and benefits of operative versus nonoperative treatment. Tear size and acuity, the presence of irreparable changes to the rotator cuff or glenohumeral joint, and patient age should all be considered in making this decision. Initial nonoperative care can be safely undertaken in older patients (>70

  17. Effects of amino acids enriched tears substitutes on the cornea of patients with dysfunctional tear syndrome.

    Science.gov (United States)

    Aragona, Pasquale; Rania, Laura; Roszkowska, Anna M; Spinella, Rosaria; Postorino, Elisa; Puzzolo, Domenico; Micali, Antonio

    2013-09-01

    To evaluate the effect of aminoacid enriched artificial tears on the ocular surface of patients with dysfunctional tear syndrome (DTS). Forty patients were divided into two groups: group 1 treated for 90 days with sodium hyaluronate (SH) 0.15% 1 drop × 5 times/day; group 2 treated for 90 days with SH 0.15% + aminoacids mixture 1 drop × 5 times/day. Symptom score questionnaire, tear break-up time (TBUT), corneal fluorescein stain, Shirmer's I test and confocal microscopy were performed at baseline and after 30 and 90 days. Confocal images underwent morphometric analysis. Both treatments improved symptoms after 1 month. Group 2 patients showed at 1 month an improvement of TBUT and corneal stain, maintained throughout the study. Also Shirmer's I test improved after 3 months. In group 1, an improvement of TBUT and corneal stain was observed after 3 months. The morphometric analysis of confocal images demonstrated at month 1 an improvement of nerve tortuosity in group 2; after 3 months both groups showed a significant improvement versus baseline. The epithelium showed, in both groups, a reduction in hyperreflective large cells starting from 1 month; the area of the cells was significantly reduced after 3 months, with a significant higher reduction in group 2. The perineural stromal opacity was significantly increased after 3 months, particularly in group 2. This is the first study addressing corneal changes after amino acids administration in a DTS population. The treatment with amino acids enriched SH can be considered a useful tool in the treatment of DTS. © 2013 The Authors Acta Ophthalmologica © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by Blackwell Publishing Ltd.

  18. Hemi-bucket-handle tears of the meniscus: appearance on MRI and potential surgical implications

    Energy Technology Data Exchange (ETDEWEB)

    Engstrom, Bjorn I.; Vinson, Emily N.; Helms, Clyde A. [Duke University Medical Center, Department of Radiology, Box 3808, Durham, NC (United States); Taylor, Dean C.; Garrett, William E. [Duke University Medical Center, Department of Orthopaedics, Box 3810, Durham, NC (United States)

    2012-08-15

    To describe a type of meniscus flap tear resembling a bucket-handle tear, named a ''hemi-bucket-handle'' tear; to compare its imaging features with those of a typical bucket-handle tear; and to discuss the potential therapeutic implications of distinguishing these two types of tears. Five knee MR examinations were encountered with a type of meniscus tear consisting of a flap of tissue from the undersurface of the meniscus displaced toward the intercondylar notch. A retrospective analysis of 100 MR examinations prospectively interpreted as having bucket-handle type tears yielded 10 additional cases with this type of tear. Cases of hemi-bucket-handle tears were reviewed for tear location and orientation, appearance of the superior articular surface of the meniscus, presence and location of displaced meniscal tissue, and presence of several classic signs of bucket-handle tears. A total of 15/15 tears involved the medial meniscus, had tissue displaced toward the notch, and were mainly horizontal in orientation. The superior surface was intact in 11/15 (73.3%). In 1/15 (6.7%) there was an absent-bow-tie sign; 6/15 (40%) had a double-PCL sign; 14/15 (93.3%) had a double-anterior horn sign. We describe a type of undersurface flap tear, named a hemi-bucket-handle tear, which resembles a bucket-handle tear. Surgeons at our institution feel this tear would likely not heal if repaired given its predominantly horizontal orientation, and additionally speculate the tear could be overlooked at arthroscopy. Thus, we feel it is important to distinguish this type of tear from the typical bucket-handle tear. (orig.)

  19. Hemi-bucket-handle tears of the meniscus: appearance on MRI and potential surgical implications

    International Nuclear Information System (INIS)

    Engstrom, Bjorn I.; Vinson, Emily N.; Helms, Clyde A.; Taylor, Dean C.; Garrett, William E.

    2012-01-01

    To describe a type of meniscus flap tear resembling a bucket-handle tear, named a ''hemi-bucket-handle'' tear; to compare its imaging features with those of a typical bucket-handle tear; and to discuss the potential therapeutic implications of distinguishing these two types of tears. Five knee MR examinations were encountered with a type of meniscus tear consisting of a flap of tissue from the undersurface of the meniscus displaced toward the intercondylar notch. A retrospective analysis of 100 MR examinations prospectively interpreted as having bucket-handle type tears yielded 10 additional cases with this type of tear. Cases of hemi-bucket-handle tears were reviewed for tear location and orientation, appearance of the superior articular surface of the meniscus, presence and location of displaced meniscal tissue, and presence of several classic signs of bucket-handle tears. A total of 15/15 tears involved the medial meniscus, had tissue displaced toward the notch, and were mainly horizontal in orientation. The superior surface was intact in 11/15 (73.3%). In 1/15 (6.7%) there was an absent-bow-tie sign; 6/15 (40%) had a double-PCL sign; 14/15 (93.3%) had a double-anterior horn sign. We describe a type of undersurface flap tear, named a hemi-bucket-handle tear, which resembles a bucket-handle tear. Surgeons at our institution feel this tear would likely not heal if repaired given its predominantly horizontal orientation, and additionally speculate the tear could be overlooked at arthroscopy. Thus, we feel it is important to distinguish this type of tear from the typical bucket-handle tear. (orig.)

  20. Linear neoclassical tearing mode in tokamaks

    International Nuclear Information System (INIS)

    Shaing, K. C.

    2007-01-01

    The growth rate of linear tearing modes in tokamaks is calculated including the neoclassical dissipation mechanism. It is found that when the growth rate is much smaller than the ion-ion collision frequency, the growth rate is reduced approximately by a factor of (B p /B) 2/5 from its standard value, and when the growth rate is much larger than the ion-ion collision frequency, the growth rate is reduced by a factor [√(ε)/(1.6q 2 )] 1/5 . Here, B p is the poloidal magnetic field strength, B is the magnetic field strength, ε is the inverse aspect ratio, and q is the safety factor. The width of the resistive layer is broadened when compared to that of the standard theory. In both limits, the growth rate and the resistive layer width only depend on B p and are independent of B. The growth rates in the plateau regime and for the inertia dominant modes are also presented

  1. Meniscus tear surgery and meniscus replacement

    Science.gov (United States)

    Vaquero, Javier; Forriol, Francisco

    2016-01-01

    Summary Objective the menisci are easily injured and difficult to repair. The aim of this study was to analyze the current state of meniscal surgery aimed at preserving morphology and conserving the biomechanics of the knee to prevent joint degeneration. Methodology a search of the electronic medical literature database Medline was conducted, from http://www.ncbi.nlm.nih.gov/pubmed. The search was not limited by language. Candidate articles were identified by searching for those that included the keywords meniscus, surgery, suture, implant, allograft. The limits were included for clinical research and clinical trials. Basic research was not included. The studies selected were evaluated and classified in three different categories: basic science, reconstruction (suture and meniscectomy) and implants (scaffolds and allograft). Results the consequences of meniscectomy performed at a young age can lead to a joint cartilage degeneration twenty years later. There are few surgical options for the repair of meniscal injuries in order both to preserve the meniscus and to ensure the long term survival of the knee joint, meniscectomy, repair, suturing the tear, or reconstruction, when a meniscal allograft or synthetic substitute is used to replace the meniscus, but the biomechanical properties of the native meniscus are not reproduced entirely by the scaffolds that exist today. Conclusion therapies that successfully repair or replace the meniscus are therefore likely to prevent or delay osteoarthritis progression. PMID:27331034

  2. Comparative study of lubricating properties of tear substitutes Systane® Ultra and Visine® Clear Tears

    Directory of Open Access Journals (Sweden)

    Yu. A. Pavlova

    2013-01-01

    Full Text Available Purpose: To compare tear substitutive properties of Systane® Ultra and Visine® Clear Tears in dry eye therapy.Methods: 20 patients with dry eye due to chronic blepharoconjunctivitis and 20 patients with neurotrophic dry eye following corneal refractive surgery were examined. Treatment schedule was the following: in the first 7 days, Systane® Ultra was instilled in the right eye and Visine® Clear Tears was instilled in the left eye, while from day 8 to day 30, only one medicine selected by the patient was applied. Their efficacy was measured by tear film stability and patients’ subjective sensations.Results: Norn test results improved to day 7 in patients with dry eye following corneal refractive surgery and to day 30 in patients with dry eye due to blepharoconjunctivitis regardless of eye drops used. As to patients’ comfort, Systane® Ultra is preferable to Visine® Clear Tears.Conclusion: Systane® Ultra is therapeutically similar to but preferable to Visine® Clear Tears due to good tolerability.

  3. Chemosignalling effects of human tears revisited: Does exposure to female tears decrease males' perception of female sexual attractiveness?

    Science.gov (United States)

    Gračanin, Asmir; van Assen, Marcel A L M; Omrčen, Višnja; Koraj, Ivana; Vingerhoets, Ad J J M

    2017-01-01

    Gelstein et al. reported the results of three experiments suggesting a dampening influence of inhalation of female emotional tears on males' arousal and perception of female sexual attractiveness, specifically in non-sexual situations. This prompted the hypothesis that crying exerts its influence on others not only via the auditory and visual mode but also via chemosignals. In three studies, we attempted to replicate and extend Gelstein et al.'s findings by including an additional condition with irritant tears, by using pictures of sexually attractive women, and by testing related hypotheses on the pro-social effects of exposure to tears. All three studies, separately or combined in a meta-analysis, failed to replicate the original inhibitory effects of tears. In addition, sniffing tears did not affect measures of connectedness, aggression and pro-social behaviour. It is concluded that the effects of female tears on male arousal and perception of female sexual attractiveness, if any, are very weak at best. Rather, it seems that crying exerts its strong inter-personal effects through the visual and auditory sensory channels.

  4. Comparative study of lubricating properties of tear substitutes Systane® Ultra and Visine® Clear Tears

    Directory of Open Access Journals (Sweden)

    Yu. A. Pavlova

    2014-07-01

    Full Text Available Purpose: To compare tear substitutive properties of Systane® Ultra and Visine® Clear Tears in dry eye therapy.Methods: 20 patients with dry eye due to chronic blepharoconjunctivitis and 20 patients with neurotrophic dry eye following corneal refractive surgery were examined. Treatment schedule was the following: in the first 7 days, Systane® Ultra was instilled in the right eye and Visine® Clear Tears was instilled in the left eye, while from day 8 to day 30, only one medicine selected by the patient was applied. Their efficacy was measured by tear film stability and patients’ subjective sensations.Results: Norn test results improved to day 7 in patients with dry eye following corneal refractive surgery and to day 30 in patients with dry eye due to blepharoconjunctivitis regardless of eye drops used. As to patients’ comfort, Systane® Ultra is preferable to Visine® Clear Tears.Conclusion: Systane® Ultra is therapeutically similar to but preferable to Visine® Clear Tears due to good tolerability.

  5. Effectiveness of Combined Tear Film Therapy in Patients with Evaporative Dry Eye with Short Tear Film Breakup Time.

    Science.gov (United States)

    Kim, Yung Hui; Kang, Yeon Soo; Lee, Hyo Seok; Choi, Won; You, In Cheon; Yoon, Kyung Chul

    2017-10-01

    The aim of this study was to evaluate the effectiveness of combined tear film therapy targeted to aqueous, mucin, and lipid layers in patients with refractory evaporative dry eye (EDE) with short tear film breakup time (TBUT). The patients who had EDE with short TBUT and severe symptoms refractory to artificial tears were treated with hyaluronic acid (HA) 0.15% and diquafosol tetrasodium (DQS) 3% (Group 1), HA and carbomer-based lipid-containing eyedrops (Liposic EDO Gel, LPO) (Group 2), or HA, DQS, and LPO (Group 3). Ocular Surface Disease Index (OSDI) score, visual analog scale (VAS) symptom score, TBUT, Schirmer score, and corneal and conjunctival staining scores were evaluated, and noninvasive tear film breakup time (NIBUT) and tear meniscus height were measured using Keratograph ® 5 M before and 1 and 3 months after treatment. OSDI scores, VAS scores, TBUT, and NIBUT were improved at 1 and 3 months after treatment in all groups (all P film layers was most effective in improving ocular symptoms and tear film quality.

  6. Glycan involvement in the adhesion of Pseudomonas aeruginosa to tears.

    Science.gov (United States)

    Kautto, Liisa; Nguyen-Khuong, Terry; Everest-Dass, Arun; Leong, Andrea; Zhao, Zhenjun; Willcox, Mark D P; Packer, Nicolle H; Peterson, Robyn

    2016-04-01

    The human eye is constantly bathed by tears, which protect the ocular surface via a variety of mechanisms. The O-linked glycans of tear mucins have long been considered to play a role in binding to pathogens and facilitating their removal in the tear flow. Other conjugated glycans in tears could similarly contribute to pathogen binding and removal but have received less attention. In the work presented here we assessed the contribution of glycan moieties, in particular the protein attached N-glycans, presented by the broad complement of tear proteins to the adhesion of the opportunistic pathogen Pseudomonas aeruginosa, a leading cause of microbial keratitis and ulceration of the cornea. Our adhesion assay involved immobilising the macromolecular components of tears into the wells of a polyvinyl difluoride (PVDF) microtitre filter plate and probing the binding of fluorescently labelled bacteria. Three P. aeruginosa strains were studied: a cytotoxic strain (6206) and an invasive strain (6294) from eye infections, and an invasive strain (320) from a urinary tract infection (UTI). The ocular isolates adhered two to three times more to human tears than to human saliva or porcine gastric mucin, suggesting ocular niche-specific adaptation. Support for the role of the N-glycans carried by human tear proteins in the binding and removal of P. aeruginosa from the eye was shown by: 1) pre-incubation of the bacteria with free component sugars, galactose, mannose, fucose and sialyl lactose (or combination thereof) inhibiting adhesion of all the P. aeruginosa strains to the immobilised tear proteins, with the greatest inhibition of binding of the ocular cytotoxic 6206 and least for the invasive 6294 strain; 2) pre-incubation of the bacteria with N-glycans released from the commercially available human milk lactoferrin, an abundant protein that carries N-linked glycans in tears, inhibiting the adhesion to tears of the ocular bacteria by up to 70%, which was significantly more

  7. Supraspinatus tendon tears: comparison of 3D US and MR arthrography with surgical correlation

    International Nuclear Information System (INIS)

    Kang, Chang Ho; Kim, Sam Soo; Kim, Jung Hyuk; Chung, Kyoo Byung; Kim, Yun Hwan; Oh, Yu-Whan; Jeong, Woong-Kyo; Kim, Baek Hyun

    2009-01-01

    The objective of the study was to compare the diagnostic reliability of 3D US with MR arthrography in diagnosing supraspinatus tendon tears, with arthroscopic findings used as the standard. In a prospective study 50 patients who later underwent arthroscopic surgery of the rotator cuff were examined pre-operatively by 3D US with MR arthrography. The presence or absence of a full- or partial-thickness supraspinatus tendon tear and the tear size as demonstrated by each imaging and arthroscopy was recorded. The tear size was divided into three grades: small ( 3 cm). The arthroscopic diagnosis was a full-thickness tear in 40 patients, partial-thickness tears in 5, and intact supraspinatus tendon in 5. 3D US correctly diagnosed 35 out of 40 full-thickness tears and MR arthrography 39 out of 40 full-thickness tears. Regarding partial-thickness tears, 3D US underestimated 2 cases as no tear and overestimated 1 case as a full-thickness tear. MR arthrography underestimated 1 case as a partial-thickness tear and overestimated 2 cases as full-thickness and partial-thickness tears respectively. 3D US and MR arthrography yield a sensitivity for full-thickness tears of 87.5% and 97.5% with specificity of 90.0% and 90.0%. Based on the grading system, 3D US measurements correctly predicted the tear size of 23 (65.7%) of the 35 full-thickness tears and MR arthrography 30 (75.0%) of the 39 full-thickness tears. Three-dimensional ultrasound seems to be a promising imaging modality comparable to MR arthrography for the assessment of the supraspinatus tendon tears. (orig.)

  8. Supraspinatus tendon tears: comparison of 3D US and MR arthrography with surgical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Chang Ho [Kangwon National University Hospital, Department of Radiology, Kangwon-do (Korea); Korea University Anam Hospital, Korea University College of Medicine, Department of Radiology, Seoul (Korea); Kim, Sam Soo [Kangwon National University Hospital, Department of Radiology, Kangwon-do (Korea); Kim, Jung Hyuk; Chung, Kyoo Byung; Kim, Yun Hwan; Oh, Yu-Whan [Korea University Anam Hospital, Korea University College of Medicine, Department of Radiology, Seoul (Korea); Jeong, Woong-Kyo [Korea University Anam Hospital, Korea University College of Medicine, Orthopaedic Surgery, Seoul (Korea); Kim, Baek Hyun [Korea University Ansan Hospital, Korea University College of Medicine, Department of Radiology, Ansan City (Korea)

    2009-11-15

    The objective of the study was to compare the diagnostic reliability of 3D US with MR arthrography in diagnosing supraspinatus tendon tears, with arthroscopic findings used as the standard. In a prospective study 50 patients who later underwent arthroscopic surgery of the rotator cuff were examined pre-operatively by 3D US with MR arthrography. The presence or absence of a full- or partial-thickness supraspinatus tendon tear and the tear size as demonstrated by each imaging and arthroscopy was recorded. The tear size was divided into three grades: small (<1 cm), medium (1-3 cm), and large (>3 cm). The arthroscopic diagnosis was a full-thickness tear in 40 patients, partial-thickness tears in 5, and intact supraspinatus tendon in 5. 3D US correctly diagnosed 35 out of 40 full-thickness tears and MR arthrography 39 out of 40 full-thickness tears. Regarding partial-thickness tears, 3D US underestimated 2 cases as no tear and overestimated 1 case as a full-thickness tear. MR arthrography underestimated 1 case as a partial-thickness tear and overestimated 2 cases as full-thickness and partial-thickness tears respectively. 3D US and MR arthrography yield a sensitivity for full-thickness tears of 87.5% and 97.5% with specificity of 90.0% and 90.0%. Based on the grading system, 3D US measurements correctly predicted the tear size of 23 (65.7%) of the 35 full-thickness tears and MR arthrography 30 (75.0%) of the 39 full-thickness tears. Three-dimensional ultrasound seems to be a promising imaging modality comparable to MR arthrography for the assessment of the supraspinatus tendon tears. (orig.)

  9. Hot tearing susceptibility of binary Mg–Y alloy castings

    International Nuclear Information System (INIS)

    Wang, Zhi; Huang, Yuanding; Srinivasan, Amirthalingam; Liu, Zheng; Beckmann, Felix; Kainer, Karl Ulrich; Hort, Norbert

    2013-01-01

    Highlights: ► Quantitatively and qualitatively assessing hot tearing susceptibility for different alloys. ► Monitoring the hot tearing propagation process. ► Detecting the hot tearing initiation/onset temperature. ► Recording the stress and strain evolution during the casting solidification and the subsequent cooling. - Abstract: The influence of Y content on the hot tearing susceptibility (HTS) of binary Mg–Y alloys has been predicted using thermodynamic calculations based on Clyne and Davies model. The calculated results are compared with experimental results determined using a constrained rod casting (CRC) apparatus with a load cell and data acquisition system. Both thermodynamic calculations and experimental measurements indicate that the hot tearing susceptibility as a function of Y content follows the “λ” shape. The experimental results show that HTS first increases with increase in Y content, reaches the maximum at about 0.9 wt.%Y and then decreases with further increase the Y content. The maximum susceptibility observed in Mg–0.9 wt.%Y alloy is attributed to its coarsened columnar microstructure, large solidification range and small amount of eutectic at the time of hot tearing. The initiation of hot cracks is monitored during CRC experiments. It corresponds to a drop in load increment on the force curves. The critical solid fractions at which the hot cracks are initiated are in the range from 0.9 to 0.99. It is also found that it decreases with increasing the content of Y. The hot cracks propagate along the dendritic or grain boundaries through the interdendritic separation or tearing of interconnected dendrites. Some of the formed cracks are possible to be healed by the subsequent refilling of the remained liquids

  10. Greenhouse Gases and Animal Agriculture

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, J. (ed.) [Department of Animal Science, Obihiro University of Agriculture and Veterinary Medicine, Obihiro, Hokkaido (Japan); Young, B.A. (ed.) [The University of Queensland, Gatton, Queensland 4343 (Australia)

    2002-07-01

    Reports from interdisciplinary areas including microbiology, biochemistry, animal nutrition, agricultural engineering and economics are integrated in this proceedings. The major theme of this book is environmental preservation by controlling release of undesirable greenhouse gases to realize the sustainable development of animal agriculture. Technology exists for the effective collection of methane generated from anaerobic fermentation of animal effluent and its use as a biomass energy source. Fossil fuel consumption can be reduced and there can be increased use of locally available energy sources. In addition, promoting environmentally-conscious agriculture which does not rely on the chemical fertilizer can be realized by effective use of animal manure and compost products.

  11. Mechanics of liquids and gases

    CERN Document Server

    Loitsyanskii, L G; Jones, W P

    1966-01-01

    Mechanics of Liquids and Gases, Second Edition is a 10-chapter text that covers significant revisions concerning the dynamics of an ideal gas, a viscous liquid and a viscous gas.After an expanded introduction to the fundamental properties and methods of the mechanics of fluids, this edition goes on dealing with the kinetics and general questions of dynamics. The next chapters describe the one-dimensional pipe flow of a gas with friction, the elementary theory of the shock tube; Riemann's theory of the wave propagation of finite intensity, and the theory of plane subsonic and supersonic flows.

  12. T-Fix endoscopic meniscal repair: technique and approach to different types of tears.

    Science.gov (United States)

    Barrett, G R; Richardson, K; Koenig, V

    1995-04-01

    Endoscopic meniscus repair using the T-Fix suture device (Acufex Microsurgical, Inc, Mansfield, MA) allows ease of suture placement for meniscus stability without the problems associated with ancillary incisions such as neurovascular compromise. It is ideal for the central posterior horn tears that are difficult using conventional techniques. Vertical tears, bucket handle tears, flap tears, and horizontal tears can be approached using a temporary "anchor stitch" to stabilize the meniscus before T-Fix repair. The basic method of repair and our approach to these different types of tears is presented.

  13. A prospective evaluation of survivorship of asymptomatic degenerative rotator cuff tears.

    Science.gov (United States)

    Keener, Jay D; Galatz, Leesa M; Teefey, Sharlene A; Middleton, William D; Steger-May, Karen; Stobbs-Cucchi, Georgia; Patton, Rebecca; Yamaguchi, Ken

    2015-01-21

    The purpose of this prospective study was to report the long-term risks of rotator cuff tear enlargement and symptom progression associated with degenerative asymptomatic tears. Subjects with an asymptomatic rotator cuff tear in one shoulder and pain due to rotator cuff disease in the contralateral shoulder enrolled as part of a prospective longitudinal study. Two hundred and twenty-four subjects (118 initial full-thickness tears, fifty-six initial partial-thickness tears, and fifty controls) were followed for a median of 5.1 years. Validated functional shoulder scores were calculated (visual analog pain scale, American Shoulder and Elbow Surgeons [ASES], and simple shoulder test [SST] scores). Subjects were followed annually with shoulder ultrasonography and clinical evaluations. Tear enlargement was seen in 49% of the shoulders, and the median time to enlargement was 2.8 years. The occurrence of tear-enlargement events was influenced by the severity of the final tear type, with enlargement of 61% of the full-thickness tears, 44% of the partial-thickness tears, and 14% of the controls (p tear enlargement. One hundred subjects (46%) developed new pain. The final tear type was associated with a greater risk of pain development, with the new pain developing in 28% of the controls, 46% of the shoulders with a partial-thickness tear, and 50% of those with a full-thickness tear (p tear enlargement was associated with the onset of new pain (p muscle were associated with tear enlargement, with supraspinatus muscle degeneration increasing in 4% of the shoulders with a stable tear compared with 30% of the shoulders with tear enlargement (p tear showed increased infraspinatus muscle degeneration compared with 28% of those in which the tear had enlarged (p = 0.07). This study demonstrates the progressive nature of degenerative rotator cuff disease. The risk of tear enlargement and progression of muscle degeneration is greater for shoulders with a full-thickness tear, and tear

  14. Diagnostic value of self-reported mechanical symptoms for diagnosing large meniscal tears in patients aged 40 years or older with meniscal tears

    DEFF Research Database (Denmark)

    Pihl, Kenneth; Englund, Martin; Lohmander, Stefan

    2017-01-01

    Purpose: Meniscal tears, which are longitudinal-vertical tears (e.g. bucket-handle tears) and/or involve all three meniscal sub regions (anterior horn, body and posterior horn), are typically large and assumed to cause patient perceived mechanical knee symptoms (knee grinding or clicking and knee...... catching or locking). However, whether the presence of such mechanical symptoms is useful for diagnosing these forms of meniscus tears is unknown. Therefore, we investigated the diagnostic values of having mechanical symptoms in diagnosing a bucket-handle tear and/or a tear involving all three meniscal sub...... regions in middle-aged and older patients undergoing arthroscopic meniscal surgery. Methods: This study is a secondary analysis of Pihl et al. OARSI 2017. The study included patients aged 40 years or older undergoing surgery for a meniscal tear from Knee Arthroscopy Cohort Southern Denmark (KACS...

  15. Acetabular labral tears in patients with sports injury.

    Science.gov (United States)

    Kang, Chan; Hwang, Deuk-Soo; Cha, Soo-Min

    2009-12-01

    We wanted to investigate acetabular labral tears and their correlation with femoroacetabular impingement in patients with sports injury. Among 111 patients who were diagnosed with the acetabular labral tears after arthroscopic treatment from January 2004 to December 2007, we selected 41 patients with sports injury. There were 12 cases of Taekwondo injury, 5 of golf injury, 4 of soccer injury, 3 of gymnastics injury, 2 of Hapkido injury, 2 of aerobics injury, 2 of rock-climbing injury, 2 of fitness training injury and 9 of other sports injuries. We checked the subtypes of acetabular labral tears and the accompanying femoroacetabular impingement. For the cases with accompanying femoroacetabular impingement, we investigated the subtypes according to the types of sports, gender and age. At last follow-up, we checked the Harris Hip Score (HHS), the Hip Outcome Score (HOS) sports scale and the percentage of patients who returned to their sports activity. The average age of symptomatic onset was 26 years (range, 12 to 65 years). The ratio of males to females was 29 : 12. An average duration of the hip pain was 17 months (range, 1 to 60 months). The degenerative type of acetabular labral tears was the most prevalent with 32 cases (78%), and there were 9 cases (22%) of the partial tear type. Thirty cases (73%) were accompanied by femoroacetabular impingement. The average age of the 23 cases (56%) of the cam-type was 23 years (range, 12 to 48 years), and it was more likely to occur in men (87%) and for people practicing martial arts such as Taekwondo or Hapkido. An average age of the 5 cases (12%) of the pincer-type was 26 (range, 16 to 43 years), it usually occurred in women (60%) and for non-martial arts such as golf and gymnastics. There were 2 cases of the mixed type (cam + pincer-type). At 27 months follow-up, the HHS was 61 to 92 points, the HOS sports scale increased 43 to 75%, and the rate of returning to sports was 71%. In spite of the early expression of symptoms

  16. Immunoglobulin Concentration in Tears of Contact Lens Wearers

    Science.gov (United States)

    Maurya, Rajendra P.; Bhushan, Prashant; Singh, Virendra P.; Singh, Mahendra K.; Kumar, Prakash; Bhatia, Ravindra P.S.; Singh, Usha

    2014-01-01

    Purpose: To evaluate changes in the concentration of tear immunoglobulins in contact lens wearers. Methods: A total of 45 cases including 23 contact lens wearers (43 eyes) and 22 age and sex matched healthy controls having no ocular pathology were studied for immunoglobulins (IgA, IgG, IgM) in their tears by single radial immunodiffusion method. Results: Most of the cases used soft (56.6%) and semi-soft gas permeable (30.4%) contact lenses. Tear IgM was detected in only 17.4% and tear IgG in 43.6% of contact lens wearers, while in controls IgG was detected in 9.1% but none of the controls had IgM. There was a significant rise in total tear IgA (13.17 ± 4.44 mg/dl) in contact lens wearer as compared to controls (8.93 ± 3.79 mg/dl). Rise of tear IgA was more in symptomatic patients (15.38 ± 5.28 mg/dl) and in those wearing hard (19.73 ± 5.43 mg/dl) and semi-soft contact lenses (13.31 ± 5.43 mg/dl). A significant increase in tear IgA was noticed in subjects wearing lenses for >3 years (15.69 ± 5.39 mg/dl). About 43.4% of lens wearers were symptomatic and 80% of their lenses showed deposits and/or haziness. All cases with IgM in tear were symptomatic. Conclusion: The relation of immunoglobulin concentration with increasing duration of wear and material of contact lens shows that tear immunoglobulin rise accrues due to mechanical stimulation, hence contact lenses should not be used for a long period and lenses of hard nature should be discouraged. The maintenance, cleaning and deproteinization of the lenses are of high importance to avoid immunostimulation. PMID:25667732

  17. Tearing resistance of some co-polyester sheets

    International Nuclear Information System (INIS)

    Kim, Ho Sung; Karger-Kocsis, Jozsef

    2004-01-01

    A three-zone model consisting of initial, evolutionary and stabilised plastic zones for tearing resistance was proposed for polymer sheets. An analysis with the model, based on the essential work of fracture (EWF) approach, was demonstrated to be capable for predicting specific total work of fracture along the tear path across all the plastic zones although accuracy of specific essential work of fracture is subject to improvement. Photo-elastic images were used for identification of plastic deformation sizes and profiles. Fracture mode change during loading was described in relation with the three zones. Tearing fracture behaviour of extruded mono- and bi-layer sheets of different types of amorphous co-polyesters and different thicknesses was investigated. Thick material exhibited higher specific total work of tear fracture than thin mono-layer sheet in the case of amorphous polyethylene terephthalate (PET). This finding was explained in terms of plastic zone size formed along the tear path, i.e., thick material underwent larger plastic deformation than thin material. When PET and polyethylene terephthalate glycol (PETG) were laminated with each other, specific total work of fracture of the bi-layer sheets was not noticeably improved over that of the constituent materials

  18. Contact Lens-Induced Discomfort and Protein Changes in Tears.

    Science.gov (United States)

    Masoudi, Simin; Stapleton, Fiona Jane; Willcox, Mark Duncan Perry

    2016-08-01

    Ocular discomfort is among the main causes of contact lens wear discontinuation. This study investigated the association between subjective ocular comfort ratings and diurnal changes in tear protein concentrations with and without contact lens wear. The study was a prospective, open-label, single-group two-staged investigation. Basal tears were collected from 30 experienced contact lens wearers twice a day (morning and evening) using a noninvasive method without lens wear (stage 1) and during wear of Etafilcon A contact lenses (stage 2) for 7 to 10 days. Subjects rated their ocular comfort on a scale of 1 to 100 (with 100 as extremely comfortable) at each time of tear collection. Tears were analyzed using liquid quadrupole mass spectrometry in conjunction with selected reaction monitoring (SRM) method. End-of-day comfort was reduced when wearing lenses (87.8 ± 14.3 AM vs. 79.2 ± 16.6 PM) compared to no lens wear (88.3 ± 12.6 AM vs. 84.7 ± 13.3 PM) (AM vs. PM, p tears (p < 0.05, r = -0.29). Only the absolute concentration of prolactin-induced protein correlated with subjective comfort ratings. Taking into consideration that prolactin-induced protein can be associated with disruption in water transport in lacrimal glands, our findings may indicate that changes to aqueous secretion are associated with contact lens discomfort.

  19. Postanaesthetic tear production and ocular irritation in cats.

    Science.gov (United States)

    Peche, N; Köstlin, R; Reese, S; Pieper, K

    2015-01-01

    General anaesthesia significantly reduces tear production and normal values are not immediately re-established on ending anaesthesia. Therefore, adequate protection of the cornea has to be assured during the perianaesthetic period. There are various methods available, including taping of the eyelids and the application of eye ointments, gels and drops. In human medicine studies, different formulations were found to induce signs of ocular irritation. The aim of the present study was to determine tear production in cats after general anaesthesia, and to identify possible causes of irritation. Tear production was determined in 41 cats after general anaesthesia and eyes were examined for signs of irritation. Two different anaesthetic protocols were used. To protect the cornea, an ointment and gel were applied to the right and left eyes, respectively. Postoperatively, tear production was significantly reduced for 6 hours and 18 hours in the right and left eyes, respectively. Two hours after anaesthesia, blepharospasm of the right eye was observed in 92.7% (n = 38) of the cats. In contrast, the left eye was always held open. This study demonstrated that tear production in cats is significantly decreased both during and after anaesthesia. The degree of reduction was independent of the anaesthetic protocol. Both the eye ointment and gel proved effective in protecting the corneal surface. However, eye gel use is recommended because the eye ointment consistently caused an irritation comparable to the foreign-body sensation reported in humans.

  20. Local effect of equilibrium current on tearing mode stability

    International Nuclear Information System (INIS)

    Cozzani, F.

    1985-12-01

    The local effect of the equilibrium current on the linear stability of low poloidal number tearing modes in tokamaks is investigated analytically. The plasma response inside the tearing layer is derived from fluid theory and the local equilibrium current is shown to couple to the mode dynamics through its gradient, which is proportional to the local electron temperature gradient under the approximations used in the analysis. The relevant eigenmode equations, expressing Ampere's law and the plasma quasineutrality condition, respectively, are suitably combined in a single integral equation, from which a variational principle is formulated to derive the mode dispersion relations for several cases of interest. The local equilibrium current is treated as a small perturbation of the known results for the m greater than or equal to 2 and the m = 1 tearing modes in the collisional regime, and the m greater than or equal to 2 tearing mode in the semicollisional regime; its effect is found to enhance stabilization for the m greater than or equal to 2 drift-tearing mode in the collisional regime, whereas the m = 1 growth rate is very slightly increased and the stabilizing effect of the parallel thermal conduction on the m greater than or equal to 2 mode in the semicollisional regime is slightly reduced

  1. Preference direction study of Job’s-tears ice cream

    Directory of Open Access Journals (Sweden)

    Wiwat Wangcharoen

    2007-09-01

    Full Text Available Job's-tears (Coix lachryma-jobi L. is a kind of cereal commonly used in Asia as food and medicine, but it is still not widely consumed in Thailand. Four prototype products of Job’s-tears ice cream were developed by varying 2 levels of glucose syrup (16 and 32% of Job's-tears used and coconut milk (50 and 100 % of Job's-tears used. Their sensory attribute profiles were evaluated by 3 groups of 10 selected panelists using Ratio profile test (RPT, and their acceptances, hedonic scores, were evaluated by 100 consumers. Results showed that there were significant effects of coconut milk quantity on several attributes, such as appearance (whiteness, texture (hardness, smoothness, and flavour (coconut milk aroma, sweetness, saltiness, but the effect of glucose syrup quantity was significant on hardness only. Acceptance data were analyzed by cluster analysis to find out the difference of preference directions and 3 clusters (n1 = 39, n2 = 25, n3 = 36 were found. The first cluster preferred Job's tears ice cream containing high glucose syrup and low coconut milk, whilst the second preferred high level of only one of these two ingredients, and the third preferred high level of both ingredients. External preference maps were created from RPT and acceptance data to express the preference direction of each cluster.

  2. Complex descemet′s membrane tears and detachment during phacoemulsification

    Directory of Open Access Journals (Sweden)

    Faik Orucoglu

    2015-01-01

    Full Text Available Purpose: To report a case of complex Descemet′s membrane detachment (DMD and tears during phacoemulsification cataract surgery. Case Report: A 64-year-old woman underwent phacoemulsification surgery in her right eye and developed tears and partial loss of Descemet′s membrane (DM while the aspiration port was inserted through the main incision. Massive corneal edema obscured the view and the anterior chamber was barely visible the following day. Scheimpflug imaging was used to complement slit lamp examination in the postoperative period. Frequent topical corticosteroid drops were initiated. After 5 days of treatment, multiple tears and detachment of DM were visible and the anterior chamber was filled with air. After 5 weeks, the cornea regained much of its clarity despite large DM tears and focal loss of DM. Conclusion: Despite partial loss of DM, the corneal edema mostly disappeared after 5 weeks of air bubble injection. Scheimpflug imaging was beneficial in the diagnosis and monitoring of DM tears and detachments.

  3. Partial and complete tear of the anterior cruciate ligament. Direct and indirect MR signs

    International Nuclear Information System (INIS)

    Chen, W.T.; Tu, H.Y.; Chen, R.C.; Shih, T.T.F.; Shau, W.Y.

    2002-01-01

    Purpose: To analyze MR direct and indirect signs for knees with anterior cruciate ligament (ACL) partial or complete tear. Material and Methods: According to documented MR direct and indirect signs for ACL tear, we retrospectively reviewed the incidence of those signs in 15 partial ACL tear and 17 complete ACL tear patients. The findings were also compared with duration of injury (less or more than 6 weeks, as acute or chronic stages). Results: A residual straight and tight ACL fiber in at least one pulse sequence was more frequently detected in partial ACL tears. The empty notch sign, a wavy contour of ACL, bone contusion at lateral compartment and lateral meniscus posterior horn tear were significantly more frequently seen in complete tear cases. The posterior cruciate ligament angle in chronic complete ACL tear cases (109 deg ±20 deg) had a tendency to be less than in chronic partial ACL tear cases (119 deg ±18 deg). Conclusion: The empty notch sign, a wavy ACL, bone contusion, and posterior horn of lateral meniscus tears are suggestive of a complete ACL tear. A residual straight and tight ACL fiber seen in at least one image section is a helpful sign to diagnosis of partial ACL tear. In the acute ACL injury stage, a focal increase of the ACL signal intensity is more suggestive of a partial ACL tear

  4. Rotator cuff tears in children and adolescents: experience at a large pediatric hospital

    International Nuclear Information System (INIS)

    Zbojniewicz, Andrew M.; Emery, Kathleen H.; Maeder, Matthew E.; Salisbury, Shelia R.

    2014-01-01

    Prior literature, limited to small case series and case reports, suggests that rotator cuff tears are rare in adolescents. However, we have identified rotator cuff tears in numerous children and adolescents who have undergone shoulder MRI evaluation. The purpose of this study is to describe the prevalence and characteristics of rotator cuff tears in children and adolescents referred for MRI evaluation of the shoulder at a large pediatric hospital and to correlate the presence of rotator cuff tears with concurrent labral pathology, skeletal maturity and patient activity and outcomes. We reviewed reports from 455 consecutive non-contrast MRI and magnetic resonance arthrogram examinations of the shoulder performed during a 2-year period, and following exclusions we yielded 205 examinations in 201 patients (ages 8-18 years; 75 girls, 126 boys). Rotator cuff tears were classified by tendon involved, tear thickness (partial or full), surface and location of tear (when partial) and presence of delamination. We recorded concurrent labral pathology when present. Physeal patency of the proximal humerus was considered open, closing or closed. Statistical analysis was performed to evaluate for a relationship between rotator cuff tears and degree of physeal patency. We obtained patient activity at the time of injury, surgical reports and outcomes from clinical records when available. Twenty-five (12.2%) rotator cuff tears were identified in 17 boys and 7 girls (ages 10-18 years; one patient had bilateral tears). The supraspinatus tendon was most frequently involved (56%). There were 2 full-thickness and 23 partial-thickness tears with articular-side partial-thickness tears most frequent (78%). Insertional partial-thickness tears were more common (78%) than critical zone tears (22%) and 10 (43%) partial-thickness tears were delamination tears. Nine (36%) patients with rotator cuff tears had concurrent labral pathology. There was no statistically significant relationship between

  5. Rotator cuff tears in children and adolescents: experience at a large pediatric hospital

    Energy Technology Data Exchange (ETDEWEB)

    Zbojniewicz, Andrew M.; Emery, Kathleen H. [University of Cincinnati College of Medicine, Department of Radiology, Cincinnati Children' s Hospital Medical Center, Cincinnati, OH (United States); Maeder, Matthew E. [University of Cincinnati College of Medicine, Department of Radiology, Cincinnati Children' s Hospital Medical Center, Cincinnati, OH (United States); Lenox Hill Hospital, Department of Radiology, New York, NY (United States); Salisbury, Shelia R. [University of Cincinnati College of Medicine, Division of Biostatistics and Epidemiology, Cincinnati Children' s Hospital Medical Center, Cincinnati, OH (United States)

    2014-06-15

    Prior literature, limited to small case series and case reports, suggests that rotator cuff tears are rare in adolescents. However, we have identified rotator cuff tears in numerous children and adolescents who have undergone shoulder MRI evaluation. The purpose of this study is to describe the prevalence and characteristics of rotator cuff tears in children and adolescents referred for MRI evaluation of the shoulder at a large pediatric hospital and to correlate the presence of rotator cuff tears with concurrent labral pathology, skeletal maturity and patient activity and outcomes. We reviewed reports from 455 consecutive non-contrast MRI and magnetic resonance arthrogram examinations of the shoulder performed during a 2-year period, and following exclusions we yielded 205 examinations in 201 patients (ages 8-18 years; 75 girls, 126 boys). Rotator cuff tears were classified by tendon involved, tear thickness (partial or full), surface and location of tear (when partial) and presence of delamination. We recorded concurrent labral pathology when present. Physeal patency of the proximal humerus was considered open, closing or closed. Statistical analysis was performed to evaluate for a relationship between rotator cuff tears and degree of physeal patency. We obtained patient activity at the time of injury, surgical reports and outcomes from clinical records when available. Twenty-five (12.2%) rotator cuff tears were identified in 17 boys and 7 girls (ages 10-18 years; one patient had bilateral tears). The supraspinatus tendon was most frequently involved (56%). There were 2 full-thickness and 23 partial-thickness tears with articular-side partial-thickness tears most frequent (78%). Insertional partial-thickness tears were more common (78%) than critical zone tears (22%) and 10 (43%) partial-thickness tears were delamination tears. Nine (36%) patients with rotator cuff tears had concurrent labral pathology. There was no statistically significant relationship between

  6. Comparisons of the Various Partial-Thickness Rotator Cuff Tears on MR Arthrography and Arthroscopic Correlation

    International Nuclear Information System (INIS)

    Chun, Kyung Ah; Kim, Min Sung; Kim, Young Joo

    2010-01-01

    To assess the diagnostic performance of MR arthrography in the diagnosis of the various types of partial-thickness rotator cuff tears by comparing the MR imaging findings with the arthroscopic findings. The series of MR arthrography studies included 202 patients consisting of 100 patients with partial-thickness rotator cuff tears proved by arthroscopy and a control group of 102 patients with arthroscopically intact rotator cuffs, which were reviewed in random order. At arthroscopy, 54 articularsided, 26 bursal-sided, 20 both articular- and bursal-sided partial-thickness tears were diagnosed. The MR arthrographies were analyzed by two radiologists for articular-sided tears, bursal-sided tears, and both articular- and bursal-sided tears of the rotator cuff. The sensitivity and specificity of each type of partial-thickness tears were determined. Kappa statistics was calculated to determine the interand intra-observer agreement of the diagnosis of partial-thickness rotator cuff tears. The sensitivity and specificity of the various types of rotator cuff tears were 85% and 90%, respectively for articular-sided tears, 62% and 95% for bursal- sided tears, as well as 45% and 99% for both articular- and bursal-sided tears. False-negative assessments were primarily observed in the diagnosis of bursal-sided tears. Conversely, both articular- and bursal-sided tears were overestimated as full-thickness tears. Inter-observer agreement was excellent for the diagnosis of articular-sided tears (k = 0.70), moderate (k = 0.59) for bursal-sided tears, and fair (k = 0.34) for both articular- and bursal-sided tears, respectively. Intra-observer agreement for the interpretation of articular- and bursal-sided tears was excellent and good, respectively, whereas intra-observer agreement for both articular- and bursal-sided tears was moderate. MR arthrography is a useful diagnostic tool for partial-thickness rotator cuff tears, but has limitations in that it has low sensitivity in bursal- and

  7. Comparisons of the Various Partial-Thickness Rotator Cuff Tears on MR Arthrography and Arthroscopic Correlation

    Energy Technology Data Exchange (ETDEWEB)

    Chun, Kyung Ah; Kim, Min Sung; Kim, Young Joo [Catholic University of Korea Uijeongbu St.Mary' s Hospital, Uijeongbu (Korea, Republic of)

    2010-10-15

    To assess the diagnostic performance of MR arthrography in the diagnosis of the various types of partial-thickness rotator cuff tears by comparing the MR imaging findings with the arthroscopic findings. The series of MR arthrography studies included 202 patients consisting of 100 patients with partial-thickness rotator cuff tears proved by arthroscopy and a control group of 102 patients with arthroscopically intact rotator cuffs, which were reviewed in random order. At arthroscopy, 54 articularsided, 26 bursal-sided, 20 both articular- and bursal-sided partial-thickness tears were diagnosed. The MR arthrographies were analyzed by two radiologists for articular-sided tears, bursal-sided tears, and both articular- and bursal-sided tears of the rotator cuff. The sensitivity and specificity of each type of partial-thickness tears were determined. Kappa statistics was calculated to determine the interand intra-observer agreement of the diagnosis of partial-thickness rotator cuff tears. The sensitivity and specificity of the various types of rotator cuff tears were 85% and 90%, respectively for articular-sided tears, 62% and 95% for bursal- sided tears, as well as 45% and 99% for both articular- and bursal-sided tears. False-negative assessments were primarily observed in the diagnosis of bursal-sided tears. Conversely, both articular- and bursal-sided tears were overestimated as full-thickness tears. Inter-observer agreement was excellent for the diagnosis of articular-sided tears (k = 0.70), moderate (k = 0.59) for bursal-sided tears, and fair (k = 0.34) for both articular- and bursal-sided tears, respectively. Intra-observer agreement for the interpretation of articular- and bursal-sided tears was excellent and good, respectively, whereas intra-observer agreement for both articular- and bursal-sided tears was moderate. MR arthrography is a useful diagnostic tool for partial-thickness rotator cuff tears, but has limitations in that it has low sensitivity in bursal- and

  8. Anterior versus posterior, and rim-rent rotator cuff tears: prevalence and MR sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Tuite, M J; Turnbull, J R; Orwin, J F [Wisconsin Univ., Madison, WI (United States). Dept. of Radiology

    1998-05-01

    Purpose. To determine the relative distribution of the locations of rotator cuff tears, and the sensitivity of anterior versus posterior tears on MR images. Patients and methods. We identified 110 consecutive patients who had a shoulder MR and either a partial-thickness or a small full-thickness rotator cuff tear diagnosed at arthroscopy. From the arthroscopy videotapes, we classified the tears as centered in the anterior or posterior half of the cuff, and as either in the critical zone or adjacent to the bony insertion. The original MR interpretation was compared with the arthroscopic findings. MR sensitivity and patient age were compared between patients with tears in the anterior and posterior halves of the cuff. In addition, in patients with partial tears less than 2 cm in diameter, an age comparison between those with tears in the critical zone and those with articular surface tears adjacent to the bony insertion (rim-rent tear) was performed. Results. The tear was centered in the anterior half of the rotator cuff in 79% of the patients younger than 36 years old, and in 89% of the patients 36 years old and over. The average age of the patients with tears in the anterior half (44 years) was not significantly different from the average age of those with posterior tears (40 years)(P=0.23). The sensitivity of MR for anterior tears was 0.69, and for posterior tears it was 0.56 (P=0.17). The average age of the 9 patients with rim-rent tears was 31 years, while that of the 28 patients with similarly-sized partial tears not involving the insertion was 40 years old (P=0.048). Five of the nine rim-rent tears (0.56) were interpreted correctly on the original MR report; two of the other tears were misinterpreted as intratendinous fluid but were diagnosable in retrospect. Conclusion. Even in patients less than 36 years old, most partial and small full-thickness rotator cuff tears are centered in the anterior half of the supraspinatus. Although our figure for MR sensitivity

  9. Pele's tears and spheres: Examples from Kilauea Iki

    Science.gov (United States)

    Porritt, L. A.; Russell, J. K.; Quane, S. L.

    2012-06-01

    Pele's tears are a well known curiosity commonly associated with low viscosity basaltic explosive eruptions. However, detailed studies of these pyroclasts are rare and, thus, there is no full explanation for their formation. These intriguing pyroclasts have smooth glassy surfaces, vesiculated interiors (∼30%), and fluidal morphologies trending towards teardrops and then spheres as they decrease in size to Pele's tears from the 1959 fire-fountaining eruption of Kilauea Iki has led to a reassessment of the mechanisms of magma disruption and fragmentation, timescales of relaxation, and cooling rates that are responsible for their formation. We conclude that the particle size distributions and vesicularities of Pele's tears are representative of the magma properties at the moment of explosive disruption. However, the morphology of these unique pyroclasts results from reshaping through viscous relaxation, driven by surface tension forces, on a time scale fast enough to compete with cooling times.

  10. Treatment of Refractory Filamentary Keratitis With Autologous Serum Tears.

    Science.gov (United States)

    Read, Sarah P; Rodriguez, Marianeli; Dubovy, Sander; Karp, Carol L; Galor, Anat

    2017-09-01

    To report a case of filamentary keratitis (FK) successfully treated with autologous serum tears and to review the pathogenesis and management of FK. Case report including high-resolution anterior segment optical coherence tomography and filament histopathology. A 61-year-old Hispanic man presented with pain and photophobia of the right eye. He was found to have a corneal epithelial defect and a small peripheral infiltrate 4 months after Laser Assisted in situ Keratomileusis. After resolution of the epithelial defect, he developed FK. Over a 4-month period, conservative management with aggressive lubrication, lid hygiene, topical corticosteroids, topical cyclosporine, bandage contact lenses, and oral doxycycline failed to resolve the corneal filaments. Notably, treatment with 20% autologous serum tears, four times daily, led to a sustained resolution of the FK within 1 week. This case demonstrates the complexity of FK management and introduces autologous serum tears as a viable management option when conservative approaches to this condition fail.

  11. Risk Factors, Pathobiomechanics and Physical Examination of Rotator Cuff Tears

    Science.gov (United States)

    Moulton, Samuel G.; Greenspoon, Joshua A.; Millett, Peter J.; Petri, Maximilian

    2016-01-01

    Background: It is important to appreciate the risk factors for the development of rotator cuff tears and specific physical examination maneuvers. Methods: A selective literature search was performed. Results: Numerous well-designed studies have demonstrated that common risk factors include age, occupation, and anatomic considerations such as the critical shoulder angle. Recently, research has also reported a genetic component as well. The rotator cuff axially compresses the humeral head in the glenohumeral joint and provides rotational motion and abduction. Forces are grouped into coronal and axial force couples. Rotator cuff tears are thought to occur when the force couples become imbalanced. Conclusion: Physical examination is essential to determining whether a patient has an anterosuperior or posterosuperior tear. Diagnostic accuracy increases when combining a series of examination maneuvers. PMID:27708731

  12. Throat gases against the CO2

    International Nuclear Information System (INIS)

    Michaut, C.

    2006-01-01

    The steel production needs carbon consumption and generates carbon dioxide, the main greenhouse gases. It represents about 6 % of the greenhouse gases emissions in the world. That is why the steel industry began last year a research program, Ideogaz, to reduce its CO 2 releases. The first results on the throat gases recovery seems very promising: it uses 25 % less of carbon. The author presents the program and the main technical aspects of the method. (A.L.B.)

  13. Optical Lattice Gases of Interacting Fermions

    Science.gov (United States)

    2015-12-02

    interacting Fermi gases has topological properties similar to the conventional chiral p- wave state. These include a non-zero Chern number and the...interacting cold gases with broad impacts on the interfaces with condensed matter and particle physics . Applications and experiments of some of the physics ...AFRL-AFOSR-VA-TR-2016-0016 Optical Lattice Gases of Interacting Fermions Wensheng Vincent Liu UNIVERSITY OF PITTSBURGH Final Report 12/02/2015

  14. Cytokine and chemokine levels in tears from healthy subjects.

    Science.gov (United States)

    Carreño, Ester; Enríquez-de-Salamanca, Amalia; Tesón, Marisa; García-Vázquez, Carmen; Stern, Michael E; Whitcup, Scott M; Calonge, Margarita

    2010-11-01

    There is growing evidence for the existence of an 'immune tone' in normal tears. The aim of this study was to determine the levels of a large panel of cytokines and chemokines in tears obtained from healthy subjects. These levels can then serve as baseline values for comparison with patients suffering from ocular surface diseases. Nine healthy subjects participated in this study, and normal ocular surface health was documented by the results of a dry eye questionnaire, Schirmer strip wetting, and vital staining of the cornea. Four microliters of tears were collected from each eye and analysed separately with multiplex bead-based assays for the concentration of 30 cytokines and chemokines. Twenty-five cytokines/chemokines were detected. CCL11/Eotaxin1, GM-CSF, G-CSF, IFN-γ, IL-2, IL-3, IL-4, IL-5, IL-10, IL-13, IL-12p70, IL-15, CX3CL1/Fractalkine, TNF-α, epidermal growth factor, and CCL4/MIP-1β were present at 5-100 pg/ml. IL-1β, IL-6, IL-7A, CXCL8/IL-8, and CCL2/MCP-1 were present at 100-400 pg/ml. IL-1Ra, CXCL10/IP-10 and vascular endothelial growth factor were present at more than 1000 pg/ml. Multiplex bead-based assays are convenient for cytokine/chemokine detection in tears. Fracktalkine has been detected in human healthy tears for the first time. The knowledge of cytokine/chemokine concentrations in tears from normal subjects is an important reference for further comparison with patients suffering from ocular surface diseases. Variability in their levels can reflect a phenomenon of potential importance for the understanding of the ocular surface cytokine pattern. © 2010 The Authors. Journal compilation © 2010 Acta Ophthalmol.

  15. Rotator cuff tears noncontrast MRI compared to MR arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Hyun; Yoon, Young Cheol [Sungkyunkwan University, School of Medicine, Department of Radiology, Samsung Medical Center, Gangnam-gu, Seoul (Korea, Republic of); Jung, Jee Young [Chungang University School of Medicine, Department of Radiology, Chungang University Hospital, Seoul (Korea, Republic of); Yoo, Jae Chul [Sungkyunkwan University, School of Medicine, Department of Orthopedic Surgery, Samsung Medical Center, Seoul (Korea, Republic of)

    2015-12-15

    To compare the accuracy of indirect magnetic resonance arthrography and noncontrast magnetic resonance imaging for diagnosing rotator cuff tears. In total, 333 patients who underwent noncontrast magnetic resonance imaging or indirect magnetic resonance arthrography were included retrospectively. Two musculoskeletal radiologists evaluated the images for the presence of supraspinatus-infraspinatus and subscapularis tendon tears. The overall diagnostic performance was calculated using the arthroscopic findings as the reference standard. Statistical differences between the diagnostic performances of the two methods were analyzed. Ninety-six and 237 patients who underwent noncontrast magnetic resonance imaging and indirect magnetic resonance arthrography were assigned into groups A and B, respectively. Sensitivity for diagnosing articular-surface partial-thickness supraspinatus-infraspinatus tendon tear was slightly higher in group B than in group A. Statistical significance was confirmed by multivariate analysis using the generalized estimating equation (p = 0.046). The specificity for diagnosing subscapularis tendon tear (85 % vs. 68 %, p = 0.012) and grading accuracy (57 % vs. 40 %, p = 0.005) was higher in group B than in group A; the differences were statistically significant for one out of two readers. Univariate analysis using the generalized estimating equation showed that the accuracy for diagnosing subscapularis tendon tear in group B was higher than in group A (p = 0.042). There were no statistically significant differences between the diagnostic performances of both methods for any other parameters. Indirect magnetic resonance arthrography may facilitate more accurate diagnosis and grading of subscapularis tendon tears compared with noncontrast magnetic resonance imaging. (orig.)

  16. Is nonoperative management of partial distal biceps tears really successful?

    Science.gov (United States)

    Bauer, Tyler M; Wong, Justin C; Lazarus, Mark D

    2018-04-01

    The current treatment of partial distal biceps tears is a period of nonoperative management, followed by surgery, if symptoms persist. Little is known about the success rate and outcomes of nonoperative management of this illness. We identified 132 patients with partial distal biceps tears through an International Classification of Diseases, Ninth Revision code query of our institution's database. Patient records were reviewed to abstract demographic information and confirm partial tears of the distal biceps tendon based on clinical examination findings and confirmatory magnetic resonance imaging (MRI). Seventy-four patients completed an outcome survey. In our study, 55.7% of the contacted patients who tried a nonoperative course (34 of 61 patients) ultimately underwent surgery, and 13 patients underwent immediate surgery. High-need patients, as defined by occupation, were more likely to report that they recovered ideally if they underwent surgery, as compared with those who did not undergo surgery (odds ratio, 11.58; P = .0138). For low-need patients, the same analysis was not statistically significant (P = .139). There was no difference in satisfaction scores between patients who tried a nonoperative course before surgery and those who underwent immediate surgery (P = .854). An MRI-diagnosed tear of greater than 50% was a predictor of needing surgery (odds ratio, 3.0; P = .006). This study has identified clinically relevant information for the treatment of partial distal biceps tears, including the following: the failure rate of nonoperative treatment, the establishment of MRI percent tear as a predictor of failing nonoperative management, the benefit of surgery for the high-need occupational group, and the finding that nonoperative management does not negatively affect outcome if subsequent surgery is necessary. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  17. Tear film proteome in age-related macular degeneration.

    Science.gov (United States)

    Winiarczyk, Mateusz; Kaarniranta, Kai; Winiarczyk, Stanisław; Adaszek, Łukasz; Winiarczyk, Dagmara; Mackiewicz, Jerzy

    2018-06-01

    Age-related macular degeneration (AMD) is the main reason for blindness in elderly people in the developed countries. Current screening protocols have limitations in detecting the early signs of retinal degeneration. Therefore, it would be desirable to find novel biomarkers for early detection of AMD. Development of novel biomarkers would help in the prevention, diagnostics, and treatment of AMD. Proteomic analysis of tear film has shown promise in this research area. If an optimal set of biomarkers could be obtained from accessible body fluids, it would represent a reliable way to monitor disease progression and response to novel therapies. Tear films were collected on Schirmer strips from a total of 22 patients (8 with wet AMD, 6 with dry AMD, and 8 control individuals). 2D electrophoresis was used to separate tear film proteins prior to their identification with matrix-assisted laser desorption/ionization time of flight spectrometer (MALDI-TOF/TOF) and matching with functional databases. A total of 342 proteins were identified. Most of them were previously described in various proteomic studies concerning AMD. Shootin-1, histatin-3, fidgetin-like protein 1, SRC kinase signaling inhibitor, Graves disease carrier protein, actin cytoplasmic 1, prolactin-inducible protein 1, and protein S100-A7A were upregulated in the tear film samples isolated from AMD patients and were not previously linked with this disease in any proteomic analysis. The upregulated proteins supplement our current knowledge of AMD pathogenesis, providing evidence that certain specific proteins are expressed into the tear film in AMD. As far we are aware, this is the first study to have undertaken a comprehensive in-depth analysis of the human tear film proteome in AMD patients.

  18. Rotator cuff tears noncontrast MRI compared to MR arthrography

    International Nuclear Information System (INIS)

    Lee, Ji Hyun; Yoon, Young Cheol; Jung, Jee Young; Yoo, Jae Chul

    2015-01-01

    To compare the accuracy of indirect magnetic resonance arthrography and noncontrast magnetic resonance imaging for diagnosing rotator cuff tears. In total, 333 patients who underwent noncontrast magnetic resonance imaging or indirect magnetic resonance arthrography were included retrospectively. Two musculoskeletal radiologists evaluated the images for the presence of supraspinatus-infraspinatus and subscapularis tendon tears. The overall diagnostic performance was calculated using the arthroscopic findings as the reference standard. Statistical differences between the diagnostic performances of the two methods were analyzed. Ninety-six and 237 patients who underwent noncontrast magnetic resonance imaging and indirect magnetic resonance arthrography were assigned into groups A and B, respectively. Sensitivity for diagnosing articular-surface partial-thickness supraspinatus-infraspinatus tendon tear was slightly higher in group B than in group A. Statistical significance was confirmed by multivariate analysis using the generalized estimating equation (p = 0.046). The specificity for diagnosing subscapularis tendon tear (85 % vs. 68 %, p = 0.012) and grading accuracy (57 % vs. 40 %, p = 0.005) was higher in group B than in group A; the differences were statistically significant for one out of two readers. Univariate analysis using the generalized estimating equation showed that the accuracy for diagnosing subscapularis tendon tear in group B was higher than in group A (p = 0.042). There were no statistically significant differences between the diagnostic performances of both methods for any other parameters. Indirect magnetic resonance arthrography may facilitate more accurate diagnosis and grading of subscapularis tendon tears compared with noncontrast magnetic resonance imaging. (orig.)

  19. Muscle architectural changes after massive human rotator cuff tear.

    Science.gov (United States)

    Gibbons, Michael C; Sato, Eugene J; Bachasson, Damien; Cheng, Timothy; Azimi, Hassan; Schenk, Simon; Engler, Adam J; Singh, Anshuman; Ward, Samuel R

    2016-12-01

    Rotator cuff (RC) tendon tears lead to negative structural and functional changes in the associated musculature. The structural features of muscle that predict function are termed "muscle architecture." Although the architectural features of "normal" rotator cuff muscles are known, they are poorly understood in the context of cuff pathology. The purpose of this study was to investigate the effects of tear and repair on RC muscle architecture. To this end thirty cadaveric shoulders were grouped into one of four categories based on tear magnitude: Intact, Full-thickness tear (FTT), Massive tear (MT), or Intervention if sutures or hardware were present, and key parameters of muscle architecture were measured. We found that muscle mass and fiber length decreased proportionally with tear size, with significant differences between all groups. Conversely, sarcomere number was reduced in both FTT and MT with no significant difference between these two groups, in large part because sarcomere length was significantly reduced in MT but not FTT. The loss of muscle mass in FTT is due, in part, to subtraction of serial sarcomeres, which may help preserve sarcomere length. This indicates that function in FTT may be impaired, but there is some remaining mechanical loading to maintain "normal" sarcomere length-tension relationships. However, the changes resulting from MT suggest more severe limitations in force-generating capacity because sarcomere length-tension relationships are no longer normal. The architectural deficits observed in MT muscles may indicate deeper deficiencies in muscle adaptability to length change, which could negatively impact RC function despite successful anatomical repair. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:2089-2095, 2016. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  20. Supraspinatus tendon tears: comparison of US and MR arthrography with surgical correlation

    International Nuclear Information System (INIS)

    Ferrari, Francesco S.; Governi, Simone; Burresi, Francesca; Vigni, Francesco; Stefani, Paolo

    2002-01-01

    The aim of this study was to compare the diagnostic reliability of US with MR arthrography in diagnosing supraspinatus tendon tears. Surgical findings were used as the gold standard in detecting tears. A total of 44 patients were assessed with transverse and longitudinal US scans with respect to the long axis of the rotator cuff tendons and then examined with MR arthrography. This technique involved free-hand injection of contrast medium into the shoulder joint. At surgery 20 incomplete and 24 complete tears were observed. Ultrasound offered good results for the large tears, but its sensitivity decreased proportionally with the size of the tears. Magnetic resonance arthrography correctly diagnosed 43 tears, whereas only one false-negative diagnosis of tendinosis was made for a partial tear on the bursal side. Since it improves the diagnosis of small tears, MR arthrography must be performed on all patients for whom surgical repair is necessary in order to restore normal functions. (orig.)

  1. Supraspinatus tendon tears: comparison of US and MR arthrography with surgical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Ferrari, Francesco S.; Governi, Simone; Burresi, Francesca; Vigni, Francesco; Stefani, Paolo [Department of Radiologic and Orthopaedic-Rehabilitative Sciences, University Hospital Siena (Italy)

    2002-05-01

    The aim of this study was to compare the diagnostic reliability of US with MR arthrography in diagnosing supraspinatus tendon tears. Surgical findings were used as the gold standard in detecting tears. A total of 44 patients were assessed with transverse and longitudinal US scans with respect to the long axis of the rotator cuff tendons and then examined with MR arthrography. This technique involved free-hand injection of contrast medium into the shoulder joint. At surgery 20 incomplete and 24 complete tears were observed. Ultrasound offered good results for the large tears, but its sensitivity decreased proportionally with the size of the tears. Magnetic resonance arthrography correctly diagnosed 43 tears, whereas only one false-negative diagnosis of tendinosis was made for a partial tear on the bursal side. Since it improves the diagnosis of small tears, MR arthrography must be performed on all patients for whom surgical repair is necessary in order to restore normal functions. (orig.)

  2. Arthroscopic repair of large U-shaped rotator cuff tears without margin convergence versus repair of crescent- or L-shaped tears.

    Science.gov (United States)

    Park, Jin-Young; Jung, Seok Won; Jeon, Seung-Hyub; Cho, Hyoung-Weon; Choi, Jin-Ho; Oh, Kyung-Soo

    2014-01-01

    For large-sized tears of the rotator cuff, data according to the tear shape have not yet been reported for repair methodology, configuration, and subsequent integrity. The retear rate after the repair of large mobile tears, such as crescent- or L-shaped tears, is believed to be lower compared with retear rates after the repair of large U-shaped tears that are accompanied by anterior or posterior leaves of the rotator cuff. Cohort study; Level of evidence, 3. Data were collected and analyzed from 95 consecutive patients with a large-sized rotator cuff tear who underwent arthroscopic suture-bridge repair. Patients were divided into 2 groups: those having crescent- or L-shaped tears (mobile tear group, 53 patients) and those having U-shaped tears (U-shaped tear group, 42 patients). The integrity of the repaired constructs was determined by ultrasonography at 4.5, 12, and 24 months. Moreover, clinical evaluations were performed by using the Constant score, the American Shoulder and Elbow Surgeons (ASES) score, and muscle strength at intervals of 3, 6, 12, and 24 months postoperatively. On ultrasonography at 4.5, 12, and 24 months, a retear was detected in 6, 2, and 1 patients in the mobile tear group and in 5, 2, and 1 patients in the U-shaped tear group, respectively. Significant differences in retear rates were not detected between the groups overall or at each time point. Moreover, clinical scores were similar between groups, except for the presence of a temporarily higher Constant score at 12 months in the mobile tear group. With regard to shoulder strength, between-group comparisons indicated no statistically significant difference, either in abduction or external rotation, except for the presence of temporarily higher external rotation strength at 3 months in the mobile tear group. Arthroscopic repair of large-sized rotator cuff tears yielded substantial improvements in shoulder function, regardless of tear retraction, during midterm follow-up. Moreover, the

  3. Noble gases in nuclear medicine

    International Nuclear Information System (INIS)

    Calderon, M.; Burdine, J.A.

    1973-01-01

    Radioactive noble gases have made a significant contribution to diagnostic nuclear medicine. In the area of regional assessment of pulmonary function, 133 Xe has had its greatest clinical impact. Following a breath of 133 Xe gas, pulmonary ventilation can be measured using a scintillation camera or other appropriate radiation detector. If 133 Xe dissolved in saline is injected intravenously, both pulmonary capillary perfusion and ventilation can be measured since 90 percent of the highly insoluble xenon escapes into the alveoli during the first passage through the lungs. Radionuclide pulmonary function tests provide the first qualitative means of assessing lung ventilation and blood flow on a regional basis, and have recently been extended to include quantification of various parameters of lung function by means of a small computer interfaced to the scintillation camera. 133 Xe is also used in the measurement of organ blood flow following injection into a vessel leading into an organ such as the brain, heart kidneys, or muscles

  4. Tear osmolarity and dry eye symptoms in diabetics

    Directory of Open Access Journals (Sweden)

    Fuerst N

    2014-03-01

    Full Text Available Nicole Fuerst,1 Nicole Langelier,1 Mina Massaro-Giordano,1 Maxwell Pistilli,1 Kalliopi Stasi,1 Carrie Burns,2 Serena Cardillo,2 Vatinee Y Bunya1 1Department of Ophthalmology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA; 2Division of Endocrinology, Diabetes, and Metabolism, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA Purpose: To assess the relationship between tear osmolarity and dry eye symptoms in patients with diabetes. Patients and methods: Fifty patients with diabetes were enrolled. Demographic information and past medical history were recorded. Symptoms were assessed using the ocular surface disease index (OSDI. Tear osmolarity of each eye was measured with the TearLab® Osmolarity System. Results: The majority of the subjects were female (76%, African American (56%, and/or had a diagnosis of type 2 diabetes (82%. The mean ± standard deviation (SD for age was 54.6±13.4, and maximum tear osmolarity was 304.6±12.7 mOsm/L. Men had higher osmolarity than women (mean ± standard error (SE 311.8±4.0 mOsm/L versus 302.3±1.9 mOsm/L, P=0.02. Age, race, use of artificial tears, years of diabetes, and hemoglobin A1c did not have a statistically significant association with tear osmolarity. Longer duration of diabetes was associated with lower (less severe OSDI scores (r=-0.35, P=0.01. Higher tear osmolarity was associated with lower (less severe OSDI scores (r=-0.29, P=0.04. Conclusion: Approximately half of the diabetic subjects in our study had elevated tear osmolarity, and half of our population also reported symptoms consistent with dry eye disease. However, the two were slightly inversely related in that those with higher osmolarity reported fewer symptoms. Subjects with a longer duration of diabetes also reported fewer dry eye symptoms. Therefore, health care providers should be aware that patients who are most likely to have ocular surface disease, including those with

  5. Daytime Variations of Tear Osmolarity Measurement in Dry Eye Patients

    Directory of Open Access Journals (Sweden)

    Ulviye Yiğit

    2013-12-01

    Full Text Available Purpose: We have targeted primarily to show the variations of tear osmolarity during the daytime period in subjects with dry eyes and non-dry eyes and, secondarily, to evaluate the relationship of these variations with Schirmer’s test and break-up time (BUT. Material and Method: Twenty newly diagnosed dry eye patients and 20 healthy voluntary subjects with similar age and gender were included in this prospective study. In addition to the full ophthalmic examination, Schirmer’s test and BUT test were applied to all participants. Tear osmolarity measurements were done after pre-examination but in different day. The measurements were registered with TearLab Osmolarity System (TearLab Corporation, San Diego, CA, USA every 3 hours within 8:00 AM and 5:00 PM. The results were evaluated statistically. Results: No statistically significant difference was found between the mean age and gender of dry eye syndrome (DES and control groups (p>0.05. The mean measurements of Schirmer’s test and BUT in the DES group were statistically significantly lower than those in the control group (p=0.0001. The mean measurements of tear osmolarity at 8:00 AM, 11:00 AM, 2:00 PM, and 5:00 PM in the DES group were statistically significantly higher than those in the control group (p=0.001, p=0.0001. No statistically significant difference in tear osmolarity at 8:00 AM, 11: 00 AM, 2:00 PM, and 5:00 PM was found between the groups, and within DES and control groups (p>0.05. Discussion: We did not determine significant change in daytime variations of the tear osmolarity in dry eye patients and healthy subjects. As a secondary result, we can conclude that there is no difference among tear osmolarity, Shirmer’s and BUT tests in the diagnosis of DES. (Turk J Ophthalmol 2013; 43: 437-41

  6. Hyper-resistivity produced by tearing mode turbulence

    International Nuclear Information System (INIS)

    Strauss, H.R.

    1986-01-01

    Tearing mode turbulence produces a hyper-resistivity or effective anomalous electron viscosity. The hyper-resistivity is calculated for the mean magnetic field quasilinearly, and for long-wavelength modes using the direct interaction approximation. The hyper-resistivity accounts for current relaxation in reversed-field pinch experiments, and gives a magnetic fluctuation sealing of S -1 /sup // 3 . It causes enhanced tearing mode growth rates in the turbulent phase of tokamak disruptions. In astrophysics, it limits magnetic energy growth due to the dynamo effect, and may explain rapid reconnection phenomena such as solar flares

  7. Mode coupling trigger of neoclassical magnetohydrodynamic tearing modes in tokamaks

    International Nuclear Information System (INIS)

    Gianakon, T.A.; Hegna, C.C.; Callen, J.D.

    1997-05-01

    Numerical studies of the nonlinear evolution of coupled magnetohydrodynamic - type tearing modes in three-dimensional toroidal geometry with neoclassical effects are presented. The inclusion of neoclassical physics introduces an additional free-energy source for the nonlinear formation of magnetic islands through the effects of a bootstrap current in Ohm's law. The neoclassical tearing mode is demonstrated to be destabilized in plasmas which are otherwise Δ' stable, albeit once a threshold island width is exceeded. A possible mechanism for exceeding or eliminating this threshold condition is demonstrated based on mode coupling due to toroidicity with a pre-existing instability at the q = 1 surface

  8. Winging of scapula due to serratus anterior tear

    Directory of Open Access Journals (Sweden)

    Varun Singh Kumar

    2014-10-01

    Full Text Available 【Abstract】Winging of scapula occurs most commonly due to injury to long thoracic nerve supplying serratus anterior muscle. Traumatic injury to serratus anterior muscle itself is very rare. We reported a case of traumatic winging of scapula due to tear of serratus anterior muscle in a 19-year-old male. Winging was present in neutral position and in extension of right shoulder joint but not on "push on wall" test. Patient was managed conservatively and achieved satisfactory result. Key words: Serratus anterior tear; Scapula; Wounds and injuries

  9. Stability of short wavelength tearing and twisting modes

    International Nuclear Information System (INIS)

    Waelbroeck, F.L.

    1998-01-01

    The stability and mutual interaction of tearing and twisting modes in a torus is governed by matrices that generalize the well-known Δ' stability index. The diagonal elements of these matrices determine the intrinsic stability of modes that reconnect the magnetic field at a single resonant surface. The off-diagonal elements indicate the strength of the coupling between the different modes. The author shows how the elements of these matrices can be evaluated, in the limit of short wavelength, from the free energy driving radially extended ballooning modes. The author applies the results by calculating the tearing and twisting Δ' for a model high-beta equilibrium with circular flux surfaces

  10. Electron diamagnetism and toroidal coupling of tearing modes

    International Nuclear Information System (INIS)

    Cowley, S.C.; Hastie, R.J.

    1987-10-01

    Using a simple model for the layer of the tearing mode, we demonstrate that toroidally coupled tearing modes with two rational surfaces are most unstable when the ω*'s of the electrons at the rational surfaces are equal. The onset of instability may then occur because of the tuning of ω* rather than the passage of Δ'-like quantities through zero. This mechanism for the onset of instability is sharp since the resonance is narrow. The effect of toroidal rotation is also discussed. 7 refs., 2 figs

  11. Energy efficiency and greenhouse gases

    International Nuclear Information System (INIS)

    Hamburg, A.; Martins, A.; Pesur, A.; Roos, I.

    1996-01-01

    Estonia's energy balance for 1990 - 1994 is characterized by the dramatic changes in the economy after regaining independence in 1991. In 1990 - 1993, primary energy supply decreased about 1.9 times. The reasons were a sharp decrease in exports of electric energy and industrial products, a steep increase in fuel prices and the transition from the planned to a market-oriented economy. Over the same period, the total amount of emitted greenhouse gases decreased about 45%. In 1993, the decrease in energy production and consumption stopped, and in 1994, a moderate increase occurred (about 6%), which is a proof stabilizing economy. Oil shale power engineering will remain the prevailing energy resource for the next 20 - 25 years. After stabilization, the use of oil shale will rise in Estonia's economy. Oil shale combustion in power plants will be the greatest source of greenhouse gases emissions in near future. The main problem is to decrease the share of CO 2 emissions from the decomposition of carbonate part of oil shale. This can be done by separating limestone particles from oil shale before its burning by use of circulating fluidized bed combustion technology. Higher efficiency of oil shale power plants facilitates the reduction of CO 2 emissions per generated MWh electricity considerably. The prognoses for the future development of power engineering depend essentially on the environmental requirements. Under the highly restricted development scenario, which includes strict limitations to emissions (CO 2 , SO 2 , thermal waste) and a severe penalty system, the competitiveness of nuclear power will increase. The conceptual steps taken by the Estonian energy management should be in compliance with those of neighboring countries, including the development programs of the other Baltic states

  12. Skin tears: care and management of the older adult at home.

    Science.gov (United States)

    Holmes, Regina F; Davidson, Martha W; Thompson, Bonnie J; Kelechi, Teresa J

    2013-02-01

    Skin tears experienced by older adults require special skills to promote healing. Home healthcare providers are in key positions to manage skin tears and prevent further skin trauma. Several guidelines, risk assessments, classifications, and products exist to manage high-risk patients. Frequent evaluation of the effectiveness of the treatment and prevention strategies in an overall skin care protocol for home care patients is critical to reduce skin tear incidence and promote prompt healing when skin tears are present.

  13. Increasing age and tear size reduce rotator cuff repair healing rate at 1 year.

    Science.gov (United States)

    Rashid, Mustafa S; Cooper, Cushla; Cook, Jonathan; Cooper, David; Dakin, Stephanie G; Snelling, Sarah; Carr, Andrew J

    2017-12-01

    Background and purpose - There is a need to understand the reasons why a high proportion of rotator cuff repairs fail to heal. Using data from a large randomized clinical trial, we evaluated age and tear size as risk factors for failure of rotator cuff repair. Patients and methods - Between 2007 and 2014, 65 surgeons from 47 hospitals in the National Health Service (NHS) recruited 447 patients with atraumatic rotator cuff tendon tears to the United Kingdom Rotator Cuff Trial (UKUFF) and 256 underwent rotator cuff repair. Cuff integrity was assessed by imaging in 217 patients, at 12 months post-operation. Logistic regression analysis was used to determine the influence of age and intra-operative tear size on healing. Hand dominance, sex, and previous steroid injections were controlled for. Results - The overall healing rate was 122/217 (56%) at 12 months. Healing rate decreased with increasing tear size (small tears 66%, medium tears 68%, large tears 47%, and massive tears 27% healed). The mean age of patients with a healed repair was 61 years compared with 64 years for those with a non-healed repair. Mean age increased with larger tear sizes (small tears 59 years, medium tears 62 years, large tears 64 years, and massive tears 66 years). Increasing age was an independent factor that negatively influenced healing, even after controlling for tear size. Only massive tears were an independent predictor of non-healing, after controlling for age. Interpretation - Although increasing age and larger tear size are both risks for failure of rotator cuff repair healing, age is the dominant risk factor.

  14. Comparison of low-abundance biomarker levels in capillary-collected nonstimulated tears and washout tears of aqueous-deficient and normal patients.

    Science.gov (United States)

    Guyette, Nicole; Williams, Larezia; Tran, My-Tho; Than, Tammy; Bradley, John; Kehinde, Lucy; Edwards, Clara; Beasley, Mark; Fullard, Roderick

    2013-05-01

    Low tear volume limits the use of nonstimulated (NS) microcapillary tear collection in aqueous-deficient (AD) patients. Adding a small amount of "washout" fluid to the eye prior to tear collection is a potentially viable alternative method for abundant proteins, but is relatively untested for low-abundance biomarkers. This study determined the feasibility of the washout (WO) method as an NS alternative for low-abundance biomarkers. NS and WO biomarker profiles were compared between AD patients and non-AD controls to determine if the two methods identify the same intergroup differences. Matching NS and WO tears were collected from 48 patients by micropipette, the WO sample after instillation of 10 μL saline. Tear cytokine levels were measured by 27-Plex Bio-Rad assay. Bland-Altman analyses for each biomarker determined the agreement between tear sample types. Patients were grouped as AD or non-AD based on Schirmer score to determine if NS profile between-group differences were preserved in WO tears. Bland-Altman plots showed good biomarker level agreement between NS and WO tears for most cytokines. Five biomarkers, among those most often cited as differing in AD dry eye, differed significantly between non-AD and AD groups in both tear types. Additional biomarker differences were seen in NS tears only. The WO tear collection method is a viable alternative to NS tears for many low-abundance biomarkers and is able to replicate major NS tear differences between dry eye groups. More subtle intergroup differences are lost in WO samples because of reduced statistical power.

  15. The natural course of nonoperatively treated rotator cuff tears: an 8.8-year follow-up of tear anatomy and clinical outcome in 49 patients.

    Science.gov (United States)

    Moosmayer, Stefan; Gärtner, Anne V; Tariq, Rana

    2017-04-01

    The natural course of nonoperatively treated rotator cuff tears is not fully understood. We explored the long-term development of tear anatomy and assessed functional outcomes. Eighty-nine small to medium-sized full-thickness tears of the rotator cuff, all primarily treated by physiotherapy, were identified retrospectively. Twenty-three tears needed surgical treatment later on, and 17 patients were unable to meet for follow-up. The remaining 49 still unrepaired tears were re-examined after 8.8 (8.2-11.0) years with sonography. Re-examination by magnetic resonance imaging was possible for 37 patients. Shoulder function was assessed with shoulder scores. Primary outcome measures were progression of tear size, muscle atrophy, and fatty degeneration and the Constant score (CS). Mean tear size increased by 8.3 mm in the anterior-posterior plane (P = .001) and by 4.5 mm in the medial-lateral plane (P = .001). Increase of tear size was -5 to +9.9 mm in 33 patients, 10 to 19.9 mm in 8 patients, and ≥20 mm in 8 patients. The CS was 81 points for tear increases Muscle atrophy and fatty degeneration progressed in 18 and 15 of the 37 patients, respectively. In tears with no progression of atrophy, the CS was 82 points compared with 75.5 points in tears with progression (P = .04). Anatomic tear deterioration was found in the majority of patients, but it was often moderate. Large tear size increases and progression of muscle atrophy were correlated to a poorer functional outcome. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  16. Instability threshold of neoclassical tearing mode, double tearing mode and off-axis sawteeth crash in tokamaks

    International Nuclear Information System (INIS)

    Li, D.

    2001-01-01

    The neoclassical and double tearing modes have been analyzed with related new phenomena in the reversed magnetic shear tokamak plasmas. The instability threshold, and the linear and nonlinear evolution are derived for the neoclassical tearing modes. It is found that the perturbed bootstrap current in the resistive layer has a stabilizing effect while the equilibrium bootstrap current in the outer region can destabilize the modes. The dispersion relation is derived for the double tearing mode. It is found that the onset of ''annular crash'' is due to the fast reconnection of the hot and cold islands, triggered by the interaction of both branches. The onset of ''core crash'' is mainly due to the coalescence between the hot islands, triggered by the explosive growth of the inner branch. (author)

  17. Instability threshold of neoclassical tearing mode, double tearing mode and off-axis sawteeth crash in tokamaks

    International Nuclear Information System (INIS)

    Li Ding

    1999-01-01

    The neoclassical and double tearing modes have been analyzed with related new phenomena in the reversed magnetic shear tokamak plasmas. The instability threshold, and the linear and nonlinear evolution are derived for the neoclassical tearing modes. It is found that the perturbed bootstrap current in the resistive layer has a stabilizing effect while the equilibrium bootstrap current in the outer region can destabilize the modes. The dispersion relation is derived for the double tearing mode. It is found that the onset of 'annular crash' is due to the fast reconnection of the hot and cold islands, triggered by the interaction of both branches. The onset of 'core crash' is mainly due to the coalescence between the hot islands, triggered by the explosive growth of the inner branch. (author)

  18. Spectral-domain optical coherence tomography study on dynamic changes of human tears after instillation of artificial tears.

    Science.gov (United States)

    Napoli, Pietro Emanuele; Satta, Giovanni Maria; Coronella, Franco; Fossarello, Maurizio

    2014-07-01

    To analyze in vivo the dynamic changes induced by different artificial tears (ATs) in the precorneal tear film (PCTF) and lower tear meniscus (LTM) by using spectral-domain (SD) anterior segment optical coherence tomography (OCT). We prospectively examined 42 normal human eyes by using SD-OCT imaging. On the day before OCT imaging, all enrolled subjects were evaluated for abnormalities of ocular surface. All tear film images were obtained before and after instillation of three different types of ATs (mucomimetic, lipid-based, and saline) in five serial scans: immediately (within 30 seconds), at the first, fifth, 10th, and 20th minute. Subjects received a drop of 35 μL in one randomly selected eye. All examinations were conducted in the same conditions of temperature, brightness, humidity, and time of day. Changes in the morphological pattern of both LTM and PCTF were associated with the type of artificial tear instilled on the ocular surface. Similarly, the radius of curvature (rc), the height (h), and the depth (d) showed dynamic variations depending on treatment. Although by the 20th minute, both h and d returned to baseline values in all groups, a significant difference in rc (compared with baseline) was detected for mucomimetic ATs (P = 0.04) and lipid ATs (P = 0.02). Spectral-domain OCT imaging has preliminarily proved to be a noninvasive tool to evaluate, in real time, the different changes induced by ATs instillation. An important stride in understanding the clinical response to various tear substitutes can be achieved by this objective and quantitative approach. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  19. Evaluation of the tear film stability after laser in situ keratomileusis using the tear film stability analysis system.

    Science.gov (United States)

    Goto, Tomoko; Zheng, Xiaodong; Klyce, Stephen D; Kataoka, Hisashi; Uno, Toshihiko; Yamaguchi, Masahiko; Karon, Mike; Hirano, Sumie; Okamoto, Shigeki; Ohashi, Yuichi

    2004-01-01

    To evaluate the tear film stability of patients before and after laser in situ keratomileusis (LASIK) using the tear film stability analysis system (TSAS). Prospective observational case series. New videokeratography software for a topographic modeling system (TMS-2N) was developed that can automatically capture consecutive corneal surface images every second for 10 seconds. Thirty-four subjects (64 eyes) who underwent myopia LASIK were enrolled in this study. All subjects were examined with the new system before LASIK and at 1 week, 1 month, 3 months, and 6 months after the surgery. Corneal topographs were analyzed for tear breakup time (TMS breakup time) and breakup area (TMS breakup area). Based on pre-LASIK TSAS analysis, subjects were separated into normal and abnormal TSAS value groups. The criteria for the normal group were either TMS breakup time more than 5 seconds or TMS breakup area less than 0.2. The percentage of the occurrence of superficial punctuate keratitis was compared between the two groups with regard to subject's dry eye signs and symptoms. Tear film stability decreased significantly during the early period after LASIK, as indexed by decreased TMS breakup time and increased TMS breakup area. Tear film instability resolved at 6 months after surgery. Before LASIK, 22 subjects (43 eyes) had normal TSAS evaluation and 12 subjects (21 eyes) were abnormal. After LASIK, among normal TSAS value eyes, 8 of 43 (18.6%) eyes developed superficial punctuate keratitis. In sharp contrast, 14 of 21 (66.7%) eyes in the abnormal group displayed superficial punctuate keratitis, correlating well with the patients' dry eye symptoms. The difference in the presence of superficial punctuate keratitis after LASIK between normal and abnormal TSAS value groups was statistically significant (P <.001). Subjects with abnormal TSAS evaluation also displayed resistance to dry eye treatment and had extended period of recovery. Tear film stability analysis can be a useful

  20. Detection of endogenous cortisol in equine tears and blood at rest and after simulated stress.

    Science.gov (United States)

    Monk, Caroline S; Hart, Kelsey A; Berghaus, Roy D; Norton, Natalie A; Moore, Phillip A; Myrna, Kathern E

    2014-07-01

    To determine whether cortisol is present in equine tears at rest and during simulated stress and compare tear cortisol to serum free and total cortisol. Fourteen healthy adult horses were included. Paired tear total cortisol and serum total and free cortisol concentrations were measured with ELISA, chemiluminescent immunoassay, and ultrafiltration methodology, respectively, in 10 horses at rest once daily for five consecutive days. In an additional four horses, paired tear and serum samples were collected for cortisol measurement before and after adrenocorticotropic hormone (ACTH) stimulation (cosyntropin, 1 μg/kg IV). Cortisol was detectable in equine tears at rest. Following ACTH stimulation, tear cortisol increased significantly from baseline at 60-120 min (P ≤ 0.001). Serum total and free cortisol also increased significantly at 30-180 min after ACTH stimulation (P ≤ 0.001). Both serum and tear cortisol returned to baseline concentrations by 360 min. Changes in tear cortisol were similarly associated with changes in serum total and free cortisol, although high tear cortisol concentrations suggest a portion of tear cortisol may be protein-bound. Cortisol is present in equine tears and increases in concert with serum cortisol following ACTH stimulation. Further study is needed to determine whether endogenous cortisol in tears contributes to ocular pathology. © 2013 American College of Veterinary Ophthalmologists.

  1. Association of Strength Measurement with Rotator Cuff Tear in Patients with Shoulder Pain: The ROW Study

    Science.gov (United States)

    Miller, Jennifer Earle; Higgins, Laurence D.; Dong, Yan; Collins, Jamie E.; Bean, Jonathan F.; Seitz, Amee L.; Katz, Jeffrey N.; Jain, Nitin B.

    2016-01-01

    Objective This study examines the association between strength measurements and supraspinatus tear in patients with shoulder pain. This study characterized determinants of abduction strength among patients with tears. Design Two-hundred and eight patients with shoulder pain (69 with and 110 without tear) were recruited. Strength was tested using hand-held dynamometer. Supraspinatus tears were diagnosed by combination of clinical assessment and blinded MRI review. Associations of supraspinatus tear with patient characteristics and strength measurements (abduction, internal rotation and external rotation) were assessed using multivariable logistic regression models. Results Patients with supraspinatus tear had decreased abduction strength (p=0.02) and decreased external rotation strength (ptear laterality, and BMI, decreased abduction strength (OR= 1.18 per kg, 95% C.I.=1.06–1.32) and decreased external rotation strength (OR=1.29 per kg, 95% C.I.=1.14–1.48) were associated with supraspinatus tear. In patients with tear, age ≥60 years, female sex, and VAS pain score were significantly associated with decreased abduction strength but tear size, fatty infiltration, and atrophy were not. Conclusions Decreased abduction and external rotation strength were associated with supraspinatus tear in patients with shoulder pain. In this cohort, the abduction strength of patients with tears, was influenced by demographic factors but not tear characteristics. PMID:26098921

  2. The relation between invasive and non-invasive tear break-up time ...

    African Journals Online (AJOL)

    Tear stability normal to Nigerians with consideration of gender and age has not been reported. Tear stability in young adults was measured using invasive and non-invasive tear break-up time (TBUT and NIBUT). Forty –five subjects aged 20 to 30 years were selected from among the students of University of. Benin, Edo ...

  3. MR imaging of the combined anterior and posterior cruciate ligament tears: focussing on the ratterns of injuries and associated findings

    International Nuclear Information System (INIS)

    Kwon, Seon Young; Choi, Chang Lak; Park, Dal Soo; Park, Eun Hee; Lee, Sang Ho; Song, Mun Kab; Lee, Kwang Won; Kwon, Soon Tae

    1997-01-01

    To evaluate the patterns of injuries and frequency of associated findings on MR imaging in patients with both anterior cruciate ligament (ACL) and posterior cruciate ligament (PCL)tears;to compare the associated findings, as seen on MR imaging, in cases with both ACL and PCL tears with those with ACL or PCL tears. Ten patients with compbined ACL and PCL tears, 16 with ACL tears and 18 with PCL tears, all confirmed by arthroscopy or open surgery, were involved in this study. To identify the associated knee injuries, MR images were retrospectively evaluated. In ten patients with combined ACL and PCL tears, open surgery led to the identification of six complete ACL tears (60%), four partial ACL tears (40%), eitht complete PCL tears (80%) and two partial PCL tears (20%). Injuries associated with these combined tears, and revealed by MR imaging, comprised six medial collateral ligament injuries (60%), six lateral collateral ligament jnjuries (60%), five medial meniscal injuries (50%), three lateral meniscal injuries (30%), nine bony injuries (90%), two posterior capsular injuries (20%), and three popliteus muscle injuries (30%). The frequency of popliteus muscle injury was significantly different (p<0.05, Fisher's exact test) between the group with both ACL and PCL tears and that with ACL or PCL tears. Associated findings in patients with combined ACL and PCL tears are more frequent than in those with ACL or PCL tears. In cases involving combined ACL and PCL tears, associated findings-as seen on MR images-should thus be carefully examined

  4. 40 CFR 89.312 - Analytical gases.

    Science.gov (United States)

    2010-07-01

    ... determined to calibration gas tolerances by chromatographic analysis of total hydrocarbons plus impurities or.... (2) Mixtures of gases having the following chemical compositions shall be available: (i) C3H8 and... check gases shall contain propane with 350 ppmC ±75 ppmC hydrocarbon. The three oxygen interference...

  5. Greenhouse Gases Concentrations in the Atmosphere Along ...

    African Journals Online (AJOL)

    This study investigated effect of vehicular emission on greenhouse gases concentrations along selected roads of different traffic densities in Abeokuta, Ogun State, Nigeria. Nine roads comprised highway, commercial and residential were selected. Greenhouse Gases (GHGs) were determined from both sides of the roads by ...

  6. Specific heats of degenerate ideal gases

    OpenAIRE

    Caruso, Francisco; Oguri, Vitor; Silveira, Felipe

    2017-01-01

    From arguments based on Heisenberg's uncertainty principle and Pauli's exclusion principle, the molar specific heats of degenerate ideal gases at low temperatures are estimated, giving rise to values consistent with the Nerst-Planck Principle (third law of Thermodynamics). The Bose-Einstein condensation phenomenon based on the behavior of specific heat of massive and non-relativistic boson gases is also presented.

  7. Method for storing radioactive rare gases

    International Nuclear Information System (INIS)

    Watabe, Atsushi; Nagao, Hiroyuki; Takiguchi, Yukio; Kanazawa, Toshio; Soya, Masataka.

    1975-01-01

    Object: To safely and securely store radioactive rare gases for a long period of time. Structure: The waste gases produced in nuclear power plant are cooled by a cooler and then introduced into a low temperature adsorbing device so that the gases are adsorbed by adsorbents, and then discharged into atmosphere through the purifying gas discharge line. When the radioactive rare gases reach a level of saturation in the amount of adsorption, they are heated and extracted by a suction pump and heated by a heater. The gases are then introduced into an oxygen-impurity removing device and the purified rare gases containing no oxygen and impurities are cooled by a cooler and fed into a gas holder. When the amount of radioactive rare gases stored within the gas holder reaches a given level, they are compressed and sealed by a compressure into a storing cylinder and residual gases in the piping are sucked and recovered into the gas holder, after which the cylinder is removed and stored in a fixed room. (Kamimura, M.)

  8. Conversion of the dominantly ideal perturbations into a tearing mode

    NARCIS (Netherlands)

    Igochine, V.; Gude, A.; Günter, S.; Lackner, K.; Yu, Q; Barrera Orte, L.; Bogomolov, A.; Classen, I.G.J.; McDermott, R.M.; Luhmann, N.C.

    2014-01-01

    Forced magnetic reconnection is a topic of common interest in astrophysics, space science, and magnetic fusion research. The tearing mode formation process after sawtooth crashes implies the existence of this type of magnetic reconnection and is investigated in great detail in the ASDEX Upgrade

  9. Equilibrium current-driven tearing mode in the hydrodynamic regime

    International Nuclear Information System (INIS)

    Cozzani, F.; Mahajan, S.

    1984-12-01

    The effect of the parallel equilibrium current on the linear stability of the drift-tearing mode in the collisional regime is investigated analytically. In the appropriate parameter regime, a new unstable mode, driven by equilibrium current, is found and its relevance to tokamak discharges is discussed

  10. Fighting, Anger, Frustration and Tears: Matthew's Story of Hegemonic Masculinity

    Science.gov (United States)

    Keddie, Amanda

    2006-01-01

    This paper draws on Matthew's story to illustrate the conflicting discourses of being a boy and being a student. Matthew is 12 years old and in Grade Six, his final year at Banrock Primary (a K-6 Australian State School). School is far from a happy place for Matthew--his tearful accounts of his combative relationships with his peers and his…

  11. Observations on Mode I ductile tearing in sheet metals

    DEFF Research Database (Denmark)

    El-Naaman, Salim Abdallah; Nielsen, Kim Lau

    2013-01-01

    Cracked ductile sheet metals, subject to Mode I tearing, have been observed to display a variety of fracture surface morphologies depending on the material properties, and a range of studies on the fracture surface appearance have been published in the literature. Whereas classical fractures...

  12. Assisted crack tip flipping under Mode I thin sheet tearing

    DEFF Research Database (Denmark)

    Felter, Christian Lotz; Nielsen, Kim Lau

    2017-01-01

    Crack tip flipping, where the fracture surface alternates from side to side in roughly 45° shear bands, seems to be an overlooked propagation mode in Mode I thin sheet tearing. In fact, observations of crack tip flipping is rarely found in the literature. Unlike the already established modes...

  13. Immunoglobulin Concentration in Tears of Contact Lens Wearers

    Directory of Open Access Journals (Sweden)

    Rajendra P Maurya

    2014-01-01

    Conclusion: The relation of immunoglobulin concentration with increasing duration of wear and material of contact lens shows that tear immunoglobulin rise accrues due to mechanical stimulation, hence contact lenses should not be used for a long period and lenses of hard nature should be discouraged. The maintenance, cleaning and deproteinization of the lenses are of high importance to avoid immunostimulation.

  14. Crack Tip Flipping Under Mode I/III Tearing

    DEFF Research Database (Denmark)

    Felter, Christian Lotz; Specht Jensen, Lasse; Nielsen, Kim Lau

    Crack tip flipping, where the fracture surface alternates from side to side in 45° shear bands, seems to be an overlooked propagation mode in Mode I sheet tearing often disregarded as  “transitional” or tied to randomness in the material. In fact, such observations rarely make it to the literature...

  15. Fracture Surface Morphology Under Ductile Tearing of Metal Plates

    DEFF Research Database (Denmark)

    Kacar, Muhammet F.; Tekoglu, Cihan; Nielsen, Kim Lau

    2017-01-01

    The present work takes as offset the hypothesis that microstructural parameters, related to particle size and distribution, govern the transition between crack surface morphologies observed in experiments. The key question is; why does tearing of a given metal plate leave a specific morphology...

  16. Tear Gas, Expanding Bullets and Plain-Clothed Personnel

    DEFF Research Database (Denmark)

    Wiesener, Cornelius Rust

    2017-01-01

    This article examines the interplay between human rights law and humanitarian law in relation to riot control agents (such as tear gas), expanding bullets and plain-clothed forces. While outlawed under humanitarian law, they are widely used by police in peace time and not subject to similar bans...

  17. A new algebraic growth of nonlinear tearing mode

    International Nuclear Information System (INIS)

    Li, D.

    1995-01-01

    It is found that the quasilinear modification of magnetic field produces a nonlinear Lorentz force opposing the linear driving force and slowing down the vortex flow. A new algebraic growth appears due to this damping mechanism to oppose the linear growth of the tearing mode. This effect was eliminated in Rutherford's model [Phys. Fluids 16, 1903 (1973)] under the flux average operation and the assumption ∂/∂t much-lt η/δ 2 (here η is the resistivity, δ is the resistive layer width). A unified analytical model is developed by using standard perturbation theory for the linear and nonlinear growth of the tearing mode. The inertia effect and quasilinear effects of both the current density and the magnetic field have been included. A nonlinear evolution equation is analytically derived for the tearing mode to describe the linear growth, Rutherford's behavior, and the new behavior. The classical linear result is exactly recovered as the quasilinear effects are negligible. It is shown that a more slowly algebraic growth like Ψ 1 ∝t can become dominant in the nonlinear phase instead of Rutherford behavior like Ψ 1 ∝t 2 , provided the tearing mode in the linear phase is strongly unstable. Here Ψ 1 is the magnetic flux perturbation. copyright 1995 American Institute of Physics

  18. Stop the Tears of Drug and Alcohol Abuse

    Science.gov (United States)

    Shimon, Jane; Gibson, Terry-Ann; Spear, Caile

    2009-01-01

    Objectives: By participating in this Stop the Tears teaching strategy, students will be able to: (1) analyze how alcohol and drug abuse could affect their lives as well as the lives of their friends and family and, (2) create a media message, such as a poster, pamphlet, poem, or song, in which alcohol and drug prevention is advocated specific to…

  19. Compensatory muscle activation in patients with glenohumeral cuff tears

    NARCIS (Netherlands)

    Steenbrink, Franciscus

    2010-01-01

    Patients suffering tendon tears in the glenohumeral cuff muscles show activation of muscles which pull the arm downwards during arm elevation tasks. This so-called co-activation deviates from healthy controls and is triggered by pain. Goal of this thesis was to demonstrate that deviating muscle

  20. THE EFFECT OF LOCAL ANESTHETICS ON TEAR PRODUCTION

    African Journals Online (AJOL)

    that local anesthetics measure only basic secretion thus reducing normal tear production/secretion, which is both reflex and basic. This could be attributed to the fact that local anesthetics have an adrenergic potentiating effects and because lacrimal fluid receive a preganglionic parasympathetic supply from lacrimal muscles ...

  1. Degenerative full thickness rotator cuff tears : Towards optimal management

    NARCIS (Netherlands)

    Lambers Heerspink, Frederik

    2016-01-01

    The shoulder is one of the most complex joints in the body. Besides a wide range of motion it also has to be stable. The rotator cuff is a major stabiliser of the glenohumoral joint. With increasing age rotator cuff tears are common. Successful treatment is described following surgical (rotator cuff

  2. Method of contacting solids and gases

    Energy Technology Data Exchange (ETDEWEB)

    1942-08-06

    A continuous method is described for contacting solids and gases. The process involves passing a confined stream of gases through an extended path including a treating zone and imposing a pressure on the stream of gases at least sufficient to overcome the resistence of said path to the flow of said gases. A solid in finely divided form is then introduced into said stream of gases, maintaining a vertical column of finely divided solid in fluidized state of a height which will produce a pressure at the column bottom at least equal to the gas pressure at the point of entry of the solids into the stream. The solids then pass from the bottom of the column into the stream.

  3. Transient Tear Film Dysfunction after Cataract Surgery in Diabetic Patients.

    Directory of Open Access Journals (Sweden)

    Donghong Jiang

    Full Text Available Diabetes mellitus is an increasingly common systemic disease. Many diabetic patients seek cataract surgery for a better visual acuity. Unlike in the general population, the influence of cataract surgery on tear film function in diabetic patients remains elusive. The aim of this study was to evaluate the tear function in diabetic and nondiabetic patients following cataract surgery.In this prospective, interventional case series, 174 diabetic patients without dry eye syndrome (DES and 474 age-matched nondiabetic patients as control who underwent phacoemulsification were enrolled at two different eye centers between January 2011 and January 2013. Patients were followed up at baseline and at 7 days, 1 month, and 3 months postoperatively. Ocular symptom scores (Ocular Surface Disease Index, OSDI and tear film function including tear film stability (tear film break-up time, TBUT, corneal epithelium integrity (corneal fluorescein staining, CFS, and tear secretion (Schirmer's I test, SIT were evaluated.In total, 83.9% of the diabetic patients (146 cases with 185 eyes and 89.0% of the nondiabetic patients (422 cases with 463 eyes completed all check-ups after the interventions (P = 0.095. The incidence of DES was 17.1% in the diabetic patients and 8.1% in the nondiabetic patients at 7 days after cataract surgery. In the diabetic patients, the incidence of DES remained 4.8% at 1 month postoperatively and decreased to zero at 3 months after surgery. No DES was diagnosed in nondiabetic patients at either the 1-month or 3-month follow-up. Compared with the baseline, the diabetic patients had worse symptom scores and lower TBUT values at 7 days and 1 month but not at 3 months postoperatively. In the nondiabetic patients, symptom scores and TBUT values had returned to preoperative levels at 1-month check-up. CFS scores and SIT values did not change significantly postoperatively in either group (P = 0.916 and P = 0.964, respectively.Diabetic patients undergoing

  4. Tearing relaxation and the globalization of transport in field-reversed configurations

    International Nuclear Information System (INIS)

    Steinhauer, Loren; Barnes, D. C.

    2009-01-01

    Tearing instability of field-reversed configurations (FRC) is investigated using the method of neighboring equilibria. It is shown that the conducting wall position in experiment lies very close to the location needed for tearing stability. This strongly suggests that vigorous but benign tearing modes, acting globally, are the engine of continual self-organization in FRCs, i.e., tearing relaxation. It also explains the ''profile consistency'' and anomalous loss rate of magnetic flux. In effect, tearing globalizes the effect of edge-driven transport.

  5. 3D Strain Modelling of Tear Fault Analogues

    Science.gov (United States)

    Hindle, D.; Vietor, T.

    2005-12-01

    Tear faults can be described as vertical discontinuities, with near fault parallel displacements terminating on some sort of shallow detachment. As such, they are difficult to study in "cross section" i.e. 2 dimensions as is often the case for fold-thrust systems. Hence, little attempt has been made to model the evolution of strain around tear faults and the processes of strain localisation in such structures due to the necessity of describing these systems in 3 dimensions and the problems this poses for both numerical and analogue modelling. Field studies suggest that strain in such regions can be distributed across broad zones on minor tear systems, which are often not easily mappable. Such strain is probably assumed to be due to distributed strain and to displacement gradients which are themselves necessary for the initiation of the tear itself. We present a numerical study of the effects of a sharp, basal discontinutiy parallel to the transport direction in a shortening wedge of material. The discontinuity is represented by two adjacent basal surfaces with strongly contrasting (0.5 and 0.05) friction coefficient. The material is modelled using PFC3D distinct element software for simulating granular material, whose properties are chosen to simulate upper crustal, sedimentary rock. The model geometry is a rectangular bounding box, 2km x 1km, and 0.35-0.5km deep, with a single, driving wall of constant velocity. We show the evolution of strain in the model in horizontal and vertical sections, and interpret strain localization as showing the spontaneous development of tear fault like features. The strain field in the model is asymmetrical, rotated towards the strong side of the model. Strain increments seem to oscillate in time, suggesting achievement of a steady state. We also note that our model cannot be treated as a critical wedge, since the 3rd dimension and the lateral variations of strength rule out this type of 2D approximation.

  6. Effect of viscosity on tear drainage and ocular residence time.

    Science.gov (United States)

    Zhu, Heng; Chauhan, Anuj

    2008-08-01

    An increase in residence time of dry eye medications including artificial tears will likely enhance therapeutic benefits. The drainage rates and the residence time of eye drops depend on the viscosity of the instilled fluids. However, a quantitative understanding of the dependence of drainage rates and the residence time on viscosity is lacking. The current study aims to develop a mathematical model for the drainage of Newtonian fluids and also for power-law non-Newtonian fluids of different viscosities. This study is an extension of our previous study on the mathematical model of tear drainage. The tear drainage model is modified to describe the drainage of Newtonian fluids with viscosities higher than the tear viscosity and power-law non-Newtonian fluids with rheological parameters obtained from fitting experimental data in literature. The drainage rate through canaliculi was derived from the modified drainage model and was incorporated into a tear mass balance to calculate the transients of total solute quantity in ocular fluids and the bioavailability of instilled drugs. For Newtonian fluids, increasing the viscosity does not affect the drainage rate unless the viscosity exceeds a critical value of about 4.4 cp. The viscosity has a maximum impact on drainage rate around a value of about 100 cp. The trends are similar for shear thinning power law fluids. The transients of total solute quantity, and the residence time agrees at least qualitatively with experimental studies. A mathematical model has been developed for the drainage of Newtonian fluids and power-law fluids through canaliculi. The model can quantitatively explain different experimental observations on the effect of viscosity on the residence of instilled fluids on the ocular surface. The current study is helpful for understanding the mechanism of fluid drainage from the ocular surface and for improving the design of dry eye treatments.

  7. A new method for tear film stability analysis using videokeratography.

    Science.gov (United States)

    Goto, Tomoko; Zheng, Xiaodong; Klyce, Stephen D; Kataoka, Hisashi; Uno, Toshihiko; Karon, Mike; Tatematsu, Yoshiyuki; Bessyo, Takeo; Tsubota, Kazuo; Ohashi, Yuichi

    2003-05-01

    To report a new tear film stability analysis system using videokeratography. Observational case series. New videokeratography software for TMS-2N (topographic modeling system; TOMEY Corporation, Nagoya, Japan) was developed that can automatically capture consecutive corneal surface images every second for 10 seconds. Forty-eight adult volunteers (80 eyes) were recruited for this study, and all subjects were examined with the new system. Corneal topographs were analyzed for tear breakup time (TMS-BUT) and the ratio of breakup area to entire color-code area (TMS-BUA) was calculated. Routine methods for tear film breakup time evaluation using slit-lamp microscope and fluorescence staining (SLE-BUT) were performed for comparison purposes. Regressive correlations of TMS-BUT or TMS-BUA with SLE-BUT were analyzed. Based on SLE results, subjects were separated into two groups with normal and short BUT, respectively. TMS-BUT and TMS-BUA were compared with SLE-BUT data with regard to the sensitivity and specificity of evaluation of dry eye symptoms. Topographic modeling system-tear breakup time (TMS-BUT) had a positive correlation with SLE-BUT (R = 0.7219, P TMS-BUA showed a negative correlation (R = 0.6317, P TMS-BUT, 9 (81.82%) of which were associated with dry eye symptoms. The sensitivities of TMS-BUT and TMS-BUA were 97.5% and 95%, respectively, significantly higher than that of SLE-BUT (75%), with P =.008 and 0.01, respectively. Topographic modeling system-BUT and TMS-BUA displayed a similar rate of specificity in comparison with SLE-BUT. This new videokeratography system is a noninvasive and objective method with increased sensitivity for tear film stability analysis.

  8. Tear trough – Anatomy and treatment by autologous fat grafting

    Directory of Open Access Journals (Sweden)

    Chang Yung Chia

    2016-07-01

    Full Text Available Tear trough is the main irregularity at midface, of which treatment is difficult. There is no agreement in literature about its anatomy and best treatment. The author presented an anatomical study and personal autologous fat grafting technique for tear trough treatment. Anatomical dissections were done on two fresh cadavers to examine the skin, subcutaneous, muscle and bone layers, spaces, and attachments. Safety and efficacy were evaluated via retrospective analysis of the last 200 consecutive procedures performed by the author. Tear trough is caused by the abrupt transition of the palpebral orbicular oculi muscle (OOM (i.e., thin skin without subcutaneous fat compartment to the orbital OOM (i.e., thicker skin with malar fat compartment. The tear trough region is located at the OOM bony origin at the medial canthus where no specific ligament was found. The grafted fat volume stabilized at two or three months after the procedure, instead of six months as stated in literature, with excellent results and no severe complications. Tear trough is a personal characteristic, a natural anatomical depression caused by subcutaneous irregularity and can worsen with age. The lack of volume is not effectively corrected by surgeries and thus it must be filled. Fat grafting has several advantages over alloplastic fillers, although it may be more difficult. Fat graft is autologous and abundant, and tissue transplantation could enhance skin quality. Fat grafting is a simple, safe, and effective solution for adding extra volume to correct the deflation phenomenon of the midface aging process. There is no specific anatomical plane for volume injection; the fat graft must be evenly distributed in the deep and superficial plane for uniformity.

  9. Kinetic Theory of Granular Gases

    Energy Technology Data Exchange (ETDEWEB)

    Trizac, Emmanuel [Center of Theoretical Biological Physics, UC San Diego, La Jolla, CA 92093-0374 (United States); Laboratoire de Physique Theorique et Modeles Statistiques, Campus Universitaire, 91405 Orsay (France)

    2005-11-25

    Granular gases are composed of macroscopic bodies kept in motion by an external energy source such as a violent shaking. The behaviour of such systems is quantitatively different from that of ordinary molecular gases: due to the size of the constituents, external fields have a stronger effect on the dynamics and, more importantly, the kinetic energy of the gas is no longer a conserved quantity. The key role of the inelasticity of collisions has been correctly appreciated for about fifteen years, and the ensuing consequences in terms of phase behaviour or transport properties studied in an increasing and now vast body of literature. The purpose of this book is to help the newcomer to the field in acquiring the essential theoretical tools together with some numerical techniques. As emphasized by the authors-who were among the pioneers in the domain- the content could be covered in a one semester course for advanced undergraduates, or it could be incorporated in a more general course dealing with the statistical mechanics of dissipative systems. The book is self-contained, clear, and avoids mathematical complications. In order to elucidate the main physical ideas, heuristic points of views are sometimes preferred to a more rigorous route that would lead to a longer discussion. The 28 chapters are short; they offer exercises and worked examples, solved at the end of the book. Each part is supplemented with a relevant foreword and a useful summary including take-home messages. The editorial work is of good quality, with very few typographical errors. In spite of the title, kinetic theory stricto sensu is not the crux of the matter covered. The authors discuss the consequences of the molecular chaos assumption both at the individual particle level and in terms of collective behaviour. The first part of the book addresses the mechanics of grain collisions. It is emphasized that considering the coefficient of restitution {epsilon} -a central quantity governing the

  10. Kinetic Theory of Granular Gases

    International Nuclear Information System (INIS)

    Trizac, Emmanuel

    2005-01-01

    Granular gases are composed of macroscopic bodies kept in motion by an external energy source such as a violent shaking. The behaviour of such systems is quantitatively different from that of ordinary molecular gases: due to the size of the constituents, external fields have a stronger effect on the dynamics and, more importantly, the kinetic energy of the gas is no longer a conserved quantity. The key role of the inelasticity of collisions has been correctly appreciated for about fifteen years, and the ensuing consequences in terms of phase behaviour or transport properties studied in an increasing and now vast body of literature. The purpose of this book is to help the newcomer to the field in acquiring the essential theoretical tools together with some numerical techniques. As emphasized by the authors-who were among the pioneers in the domain- the content could be covered in a one semester course for advanced undergraduates, or it could be incorporated in a more general course dealing with the statistical mechanics of dissipative systems. The book is self-contained, clear, and avoids mathematical complications. In order to elucidate the main physical ideas, heuristic points of views are sometimes preferred to a more rigorous route that would lead to a longer discussion. The 28 chapters are short; they offer exercises and worked examples, solved at the end of the book. Each part is supplemented with a relevant foreword and a useful summary including take-home messages. The editorial work is of good quality, with very few typographical errors. In spite of the title, kinetic theory stricto sensu is not the crux of the matter covered. The authors discuss the consequences of the molecular chaos assumption both at the individual particle level and in terms of collective behaviour. The first part of the book addresses the mechanics of grain collisions. It is emphasized that considering the coefficient of restitution ε -a central quantity governing the inelasticity of

  11. The storage of greenhouse gases

    International Nuclear Information System (INIS)

    Herzog, H.; Kaarstad, O.; Eliasson, B

    2000-01-01

    Since 1850, that is to say the beginning of the industrial era,the concentration of carbon dioxide in the atmosphere has risen from 280 ppm to 370 ppm, this increase is mainly due to the combustion of fossil fuels. Today fossil fuels represent 85% of all the energy used in the world. Fearing progressive climatic changes, more and more governments become aware of the necessity of reducing the emission of greenhouse gases. A more efficient use of energy and the promoting of renewable energies and of the nuclear energy are the most evident solutions but they appear to be insufficient. A third solution is the storage of carbon dioxide in geological layers. This technique has been put into use since 1996 in Norway. An off-shore natural gas platform injects carbon dioxide in a geological reservoir situated 1000 meters below the ocean bed. The injection of CO 2 could be used in oil fields in order to facilitate the extraction of petroleum. Far more large and efficient reservoirs would be the oceans, they already hold up 40000 10 9 tons of dissolved CO 2 . Even if the double of the carbon dioxide accumulated in the atmosphere since 1850 were injected, the concentration of carbon in sea waters would rise by less than 2%. The safety of CO 2 storage and the impact on the environment of ocean injection sites are being studied. (A.C.)

  12. Greenhouse gases and emissions trading

    International Nuclear Information System (INIS)

    LeBlanc, A.; Dudek, D.J.

    1993-01-01

    Global cooperation is essential in cutting greenhouse-gas emissions, say Alice LeBlanc and Daniel J. Dudek of the Environmental Defense in New York City. The first step, they continue, is agreement among nations on an overall global limit for all greenhouse gases, followed by an allocation of the global limit among nations. The agreements must contain effective reporting and monitoring systems and enforcement provisions, they add. The Framework Convention on Climate Change, signed by most nations of the world in Brazil in 1992, provides the foundation for such an agreement, LeBlanc and Dudek note. open-quotes International emissions trading is a way to lower costs and expand reduction options for the benefit of all,close quotes they contend. Under such an arrangement, an international agency would assign allowances, stated in tons of carbon dioxide. Countries would be free to buy and sell allowances, but no country could exceed, in a given year, the total allowances it holds. By emitting less than its allowed amount, a country would accumulate more allowances, which it could sell. The authors claim such a system would offer benefits to the world economy by saving billions of dollars in pollution-reduction costs while still achieving emission limits established in an international agreement

  13. Chemosignalling effects of human tears revisited: Does exposure to female tears decrease males' perception of female sexual attractiveness?

    NARCIS (Netherlands)

    Gračanin, Asmir; van Assen, Marcel A L M|info:eu-repo/dai/nl/407629971; Omrčen, Višnja; Koraj, Ivana; Vingerhoets, Ad J J M

    2016-01-01

    Gelstein et al. reported the results of three experiments suggesting a dampening influence of inhalation of female emotional tears on males' arousal and perception of female sexual attractiveness, specifically in non-sexual situations. This prompted the hypothesis that crying exerts its influence on

  14. Chemosignalling effects of human tears revisited : Does exposure to female tears decrease males' perception of female sexual attractiveness?

    NARCIS (Netherlands)

    Gracanin, A.; van Assen, M.A.L.M.; Omrčen, Višnja; Koraj, Ivana; Vingerhoets, A.J.J.M.

    2017-01-01

    Gelstein et al. reported the results of three experiments suggesting a dampening influence of inhalation of female emotional tears on males' arousal and perception of female sexual attractiveness, specifically in non-sexual situations. This prompted the hypothesis that crying exerts its influence on

  15. Cemental tear: To know what we have neglected in dental practice

    Directory of Open Access Journals (Sweden)

    Po-Yuan Jeng

    2018-04-01

    Full Text Available Cemental tear is a special kind of root surface fracture, contributing to periodontal and periapical breakdown. However, it is a challenge for doctors to diagnose, resulting in delayed or improper treatment. We reviewed the predisposing factors, location, radiographic/clinical characteristics, diagnosis and treatments of cemental tears. From the literature, patients with cemental tear were mainly males, over 60 year-old. Possible predisposing factors include gender, age, tooth type, traumatic occlusal force and vital teeth. Cemental tears were common in upper and lower anterior teeth, single or multiple, and can be present in cervical, middle and apical third of roots. Morphology of cemental tears can be either piece-shaped or U-shaped. Clinically, cemental tear shows a unitary periodontal pocket and signs/symptoms mimicking localized periodontitis, apical periodontitis and vertical root fractures. Treatment of cemental tears include scaling, root planning, root canal treatment, periodontal/periapical surgery, guided tissue regeneration, bone grafting, and intentional replantation. Recurrence of cemental tear is possible especially when the fracture involves root apex. Extraction is recommended for teeth with poor prognosis. In conclusion, cemental tears can involve both periodontal and periapical area. Dentists should understand the predisposing factors and clinical features of cemental tears for early diagnosis/treatment to prevent bone loss/tooth extraction. Keywords: Cemental tear, Clinical characteristics, Surface root fracture, Periodontal/periapical breakdown, Recurrence, Predisposing factors

  16. Acute and chronic tears of anterior cruciate ligament : role of gadolinium-enhanced MR imaging

    International Nuclear Information System (INIS)

    Lee, Eun Jung; Jee, Won Hee; Im, Soo A; Chun, Ho Jong; Jung, Hyun Seouk; Kim, Soo Young; Kwon, Tae An; Song, Sun Wha; Choi, Kyu Ho

    1998-01-01

    To evaluate the efficacy of fat-suppressed gadolinium-enhanced MR imaging in differentiating acute from chronic ligament tears of anterior cruciate ligament. Materials and Methods : MR images of 22 patients with arthroscopically proven complete tear of the anterior cruciate ligament were retrospectively reviewed. The interval between injury and MR examination was one day to seven years. When ligament tear was detected on MR image with three months of injury, the case was considered acute;if detected after three months had elapsed, it was judged to be chronic. The extent of contrast enhancement was graded as 1, 2 or 3; grade 1, enhancement was confined to the expected ligament region; grade 2, enhancement extended to the joint capsule; grade 3, enhancement extended beyond the joint capsule. The grades of contrast enhancement correlated with the acute and chronic stages of ligament tears. Associated bone bruise and/or adjacent soft tissue edema were also evaluated. Results : Among 15 patients with acute ligament tear, nine (60%) showed grade 3 enhancement; among seven in whom tearing was chronic, four (57%) showed grade 1 enhancement. Bone bruising was present in 100% of acute tears (15/15) and 29 % of chronic tears (2/7). Soft tissue edema was associated in 87% of acute tears (13/15) and 29% of chronic tears(2/7). Conclusion : Fat-suppressed gadolinium-enhanced MR imaging could help differentiate acute from chronic tears of anterior cruciate ligament, as well as bone bruising and tissue edema

  17. Prevalence of triceps tendon tears on MRI of the elbow and clinical correlation

    International Nuclear Information System (INIS)

    Koplas, Monica C.; Schneider, Erika; Sundaram, Murali

    2011-01-01

    Triceps tendon injuries are reported to be very rare. To our knowledge, there have been no studies describing its prevalence or injury patterns on MR imaging. The purpose of this retrospective study was to determine the prevalence and patterns of triceps injuries based on a large series of consecutive MR examinations. Clinical correlation was obtained. From 801 consecutive elbow MR examinations over a 15-year period, 28 patients with 30 triceps tendon injuries were identified and graded as partial tendon tear and complete tendon tear. The patients' medical records were reviewed to determine age, gender, cause of tears, and management. The prevalence of triceps tendon injuries was 3.8%. There were 5 women and 23 men with partial or complete tears (mean age: 46.6 years; range: 2.7 to 75.1 years). The most common injury was partial tear, found in 18 patients. There were 10 patients with 12 complete tears (2 had re-torn following surgical repair). A tear was suspected in 12 out 28 (43%) patients prior to the MRI. The most common presenting symptom was pain. The most common cause was athletic injury (8 patients [29%], including weightlifting [2 patients]). Tendon tear was found to be a complication of infection in 6 patients, and in 3 patients the tears were a complication of steroid use. Thirteen tendon tears were surgically repaired (8 of these were complete tears). Triceps tendon injury is not as rare as commonly reported and may often be clinically underdiagnosed. (orig.)

  18. Prevalence of triceps tendon tears on MRI of the elbow and clinical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Koplas, Monica C. [University of Mississippi Medical Center, Section of Musculoskeletal Radiology, Department of Radiology, Jackson, MS (United States); Schneider, Erika [Cleveland Clinic, Imaging Institute, Cleveland, OH (United States); Sundaram, Murali [Cleveland Clinic, Section of Musculoskeletal Radiology, Imaging Institute, Cleveland, OH (United States)

    2011-05-15

    Triceps tendon injuries are reported to be very rare. To our knowledge, there have been no studies describing its prevalence or injury patterns on MR imaging. The purpose of this retrospective study was to determine the prevalence and patterns of triceps injuries based on a large series of consecutive MR examinations. Clinical correlation was obtained. From 801 consecutive elbow MR examinations over a 15-year period, 28 patients with 30 triceps tendon injuries were identified and graded as partial tendon tear and complete tendon tear. The patients' medical records were reviewed to determine age, gender, cause of tears, and management. The prevalence of triceps tendon injuries was 3.8%. There were 5 women and 23 men with partial or complete tears (mean age: 46.6 years; range: 2.7 to 75.1 years). The most common injury was partial tear, found in 18 patients. There were 10 patients with 12 complete tears (2 had re-torn following surgical repair). A tear was suspected in 12 out 28 (43%) patients prior to the MRI. The most common presenting symptom was pain. The most common cause was athletic injury (8 patients [29%], including weightlifting [2 patients]). Tendon tear was found to be a complication of infection in 6 patients, and in 3 patients the tears were a complication of steroid use. Thirteen tendon tears were surgically repaired (8 of these were complete tears). Triceps tendon injury is not as rare as commonly reported and may often be clinically underdiagnosed. (orig.)

  19. Prevalence of triceps tendon tears on MRI of the elbow and clinical correlation.

    Science.gov (United States)

    Koplas, Monica C; Schneider, Erika; Sundaram, Murali

    2011-05-01

    Triceps tendon injuries are reported to be very rare. To our knowledge, there have been no studies describing its prevalence or injury patterns on MR imaging. The purpose of this retrospective study was to determine the prevalence and patterns of triceps injuries based on a large series of consecutive MR examinations. Clinical correlation was obtained. From 801 consecutive elbow MR examinations over a 15-year period, 28 patients with 30 triceps tendon injuries were identified and graded as partial tendon tear and complete tendon tear. The patients' medical records were reviewed to determine age, gender, cause of tears, and management. The prevalence of triceps tendon injuries was 3.8%. There were 5 women and 23 men with partial or complete tears (mean age: 46.6 years; range: 2.7 to 75.1 years). The most common injury was partial tear, found in 18 patients. There were 10 patients with 12 complete tears (2 had re-torn following surgical repair). A tear was suspected in 12 out 28 (43%) patients prior to the MRI. The most common presenting symptom was pain. The most common cause was athletic injury (8 patients [29%], including weightlifting [2 patients]). Tendon tear was found to be a complication of infection in 6 patients, and in 3 patients the tears were a complication of steroid use. Thirteen tendon tears were surgically repaired (8 of these were complete tears). Triceps tendon injury is not as rare as commonly reported and may often be clinically underdiagnosed.

  20. Bucket handle tears of the medial meniscus: meniscal intrusion rather than meniscal extrusion

    International Nuclear Information System (INIS)

    Schlossberg, S.; Umans, H.; Flusser, G.; DiFelice, G.S.; Lerer, D.B.

    2007-01-01

    To determine the frequency of medial meniscal extrusion (MME) versus ''medial meniscal intrusion'' in the setting of bucket handle tears. Images were evaluated for previously reported risk factors for MME, including: medial meniscal root tear, radial tear, degenerative joint disease and joint effusion. Forty-one consecutive cases of bucket handle tear of the medial meniscus were reviewed by consensus by two musculoskeletal radiologists. Imaging was performed using a 1.5 GE Signa MR unit. Patient age, gender, medial meniscal root integrity, MME, medial meniscal intrusion, degenerative joint disease, effusion and anterior cruciate ligament (ACL) tear were recorded. Thirteen females and 27 males (age 12-62 years, median=30 years) were affected; one had bucket handle tear of each knee. Effusion was small in 13, moderate in 9 and large in 18. Degenerative joint disease was mild in three, moderate in two and severe in one. 26 ACL tears included three partial and three chronic. Medial meniscal root tear was complete in one case and partial thickness in two. None of the 40 cases with an intact or partially torn medial meniscal root demonstrated MME. MME of 3.1 mm was seen in the only full-thickness medial meniscal root tear, along with chronic ACL tear, moderate degenerative joint disease and large effusion. Medial meniscal intrusion of the central bucket handle fragment into the intercondylar notch was present in all 41 cases. Given an intact medial meniscal root in the setting of a ''pure'' bucket handle tear, there is no MME. (orig.)

  1. Relationship between massive chronic rotator cuff tear pattern and loss of active shoulder range of motion.

    Science.gov (United States)

    Collin, Philippe; Matsumura, Noboru; Lädermann, Alexandre; Denard, Patrick J; Walch, Gilles

    2014-08-01

    Management of massive chronic rotator cuff tears remains controversial, with no clearly defined clinical presentation as yet. The purpose of the study was to evaluate the effect of tear size and location on active motion in patients with chronic and massive rotator cuff tears with severe muscle degeneration. One hundred patients with massive rotator cuff tears accompanied by muscle fatty infiltration beyond Goutallier stage 3 were prospectively included in this study. All patients were divided into 5 groups on the basis of tear pattern (supraspinatus, superior subscapularis, inferior subscapularis, infraspinatus, and teres minor). Active range of shoulder motion was assessed in each group and differences were analyzed. Active elevation was significantly decreased in patients with 3 tear patterns involved. Pseudoparalysis was found in 80% of the cases with supraspinatus and complete subscapularis tears and in 45% of the cases with tears involving the supraspinatus, infraspinatus, and superior subscapularis. Loss of active external rotation was related to tears involving the infraspinatus and teres minor; loss of active internal rotation was related to tears of the subscapularis. This study revealed that dysfunction of the entire subscapularis and supraspinatus or 3 rotator cuff muscles is a risk factor for pseudoparalysis. For function to be preserved in patients with massive chronic rotator cuff tears, it may be important to avoid fatty infiltration with anterior extension into the lower subscapularis or involvement of more than 2 rotator cuff muscles. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  2. Tear function and ocular surface after Muller muscle-conjunctival resection.

    Science.gov (United States)

    Uğurbaş, Suat Hayri; Alpay, Atilla; Bahadır, Burak; Uğurbaş, Sılay Cantürk

    2014-05-01

    Muller muscle-conjunctival resection (MCR) is a surgical technique to correct mild and moderate ptosis. In this study, tear function tests and ocular surface are evaluated in patients who underwent unilateral surgery. Sixteen patients with normal preoperative tear function who underwent unilateral MCR were evaluated prospectively. The fellow eyes of the patients were taken as the control group. A dry eye assessment questionnaire, Schirmer testing, tear film break-up time, fluorescein stain, Rose-Bengal stain, and conjunctival impression cytology were used to assess the tear film functions and ocular surface changes in the operated and non-operated eyes. There was no statistically significant difference in the tear function tests and goblet cell densities between the operated and non-operated eyes. The results indicate that an MCR procedure has no apparent effect on tear function tests and goblet cell density in patients with normal preoperative tear function.

  3. Rotator cuff tears: assessment with MR arthrography in 275 patients with arthroscopic correlation

    International Nuclear Information System (INIS)

    Waldt, S.; Bruegel, M.; Mueller, D.; Holzapfel, K.; Rummeny, E.J.; Woertler, K.; Imhoff, A.B.

    2007-01-01

    We assessed the diagnostic performance of magnetic resonance (MR) arthrography in the diagnosis of articular-sided partial-thickness and full-thickness rotator cuff tears in a large symptomatic population. MR arthrograms obtained in 275 patients including a study group of 139 patients with rotator cuff tears proved by arthroscopy and a control group of 136 patients with arthroscopically intact rotator cuff tendons were reviewed in random order. MR imaging was performed on a 1.0 T system (Magnetom Expert, Siemens). MR arthrograms were analyzed by two radiologists in consensus for articular-sided partial-thickness and full-thickness tears of the supraspinatus, infraspinatus, and subscapularis tendons. At arthroscopy, 197 rotator cuff tears were diagnosed, including 105 partial-thickness (93 supraspinatus, nine infraspinatus, three subscapularis) and 92 full-thickness (43 supraspinatus, 20 infraspinatus, 29 subscapularis) tendon tears. For full-thickness tears, sensitivity, specificity, and accuracy were 96%, 99%, and 98%, respectively, and for partial tears 80%, 97%, and 95%, respectively. False negative and positive assessments in the diagnosis of articular-sided partial-thickness tears were predominantly [78% (35/45)] observed with small articular-sided (Ellman grade1) tendon tears. MR arthrography is highly accurate in the diagnosis of full-thickness rotator cuff tears and is accurate in the diagnosis of articular-sided partial-thickness tears. Limitations in the diagnosis of partial-thickness tears are mainly restricted to small articular-sided tears (Ellman grade 1) due to difficulties in differentiation between fiber tearing, tendinitis, synovitic changes, and superficial fraying at tendon margins. (orig.)

  4. Kissing contusion between the posterolateral tibial plateau and lateral femoral condyle: associated ligament and meniscal tears

    International Nuclear Information System (INIS)

    Hong, Hyun Pyo; Lee, Jae Gue; Park, Ji Seon; Ryu, Kyung Nam

    2004-01-01

    Kissing contusion between the posterolateral tibial plateau and lateral femoral condyle is frequently found in association with a tear of the anterior cruciate liagment (ACL). The purpose of this study was to determine which ligamentous and meniscal tears are associated with kissing contusion. We retrospectively reviewed the findings depicted by 323 consecutive MR images of the knee and confirmed at arthroscopy. For the diagnosis of disruption, ligaments, medial menisci (MM) and lateral menisci (LM) were evaluated using accepted criteria. We compared the prevalence and location of meniscal and ligamentous tears between group I (44 knees with kissing contusion) and group II (279 knees without kissing contusion). For statistical analysis the chi-square test was used. ACLs were torn in all 44 knees (100%) with kissing contusion, and 78 (28%) of 279 without kissing contusion. There were ten medial collateral ligament (MCL) tears (23%) in group I, and 17 MCL tears (6%), five lateral collateral ligament (LCL) tears (2%) and ten posterior cruciate ligament (PCL) tears (4%) in group II. In group I, meniscal tears were found in 22 MM (50%) and in 19 LM (43%), while in group II, they occurred in 128 MM (46%) and 128 LM (46%), In group I, 17 (77%) of 22 MM tears and 13 (68%) of 19 LM tears were located in the posterior horn, while in group II, the corresponding figures were 97/128 (76%) and 60 of 128 (47%). The differing prevalence of ACL and MCL tears between the groups was statistically significant (p 0.05). Although kissing contusion was a highly specific sign of ACL tears, its presence was also significant among MCL tears. There was no significant difference in meniscal tears with or without kissing contusion

  5. Goldmann tonometry tear film error and partial correction with a shaped applanation surface.

    Science.gov (United States)

    McCafferty, Sean J; Enikov, Eniko T; Schwiegerling, Jim; Ashley, Sean M

    2018-01-01

    The aim of the study was to quantify the isolated tear film adhesion error in a Goldmann applanation tonometer (GAT) prism and in a correcting applanation tonometry surface (CATS) prism. The separation force of a tonometer prism adhered by a tear film to a simulated cornea was measured to quantify an isolated tear film adhesion force. Acrylic hemispheres (7.8 mm radius) used as corneas were lathed over the apical 3.06 mm diameter to simulate full applanation contact with the prism surface for both GAT and CATS prisms. Tear film separation measurements were completed with both an artificial tear and fluorescein solutions as a fluid bridge. The applanation mire thicknesses were measured and correlated with the tear film separation measurements. Human cadaver eyes were used to validate simulated cornea tear film separation measurement differences between the GAT and CATS prisms. The CATS prism tear film adhesion error (2.74±0.21 mmHg) was significantly less than the GAT prism (4.57±0.18 mmHg, p film adhesion error was independent of applanation mire thickness ( R 2 =0.09, p =0.04). Fluorescein produces more tear film error than artificial tears (+0.51±0.04 mmHg; p film adhesion error (1.40±0.51 mmHg) was significantly less than that of the GAT prism (3.30±0.38 mmHg; p =0.002). Measured GAT tear film adhesion error is more than previously predicted. A CATS prism significantly reduced tear film adhesion error bŷ41%. Fluorescein solution increases the tear film adhesion compared to artificial tears, while mire thickness has a negligible effect.

  6. Rotator cuff tears: assessment with MR arthrography in 275 patients with arthroscopic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Waldt, S.; Bruegel, M.; Mueller, D.; Holzapfel, K.; Rummeny, E.J.; Woertler, K. [Technische Universitaet Muenchen, Department of Radiology, Munich (Germany); Imhoff, A.B. [Technische Universitaet Muenchen, Department of Sports Orthopedics, Munich (Germany)

    2007-02-15

    We assessed the diagnostic performance of magnetic resonance (MR) arthrography in the diagnosis of articular-sided partial-thickness and full-thickness rotator cuff tears in a large symptomatic population. MR arthrograms obtained in 275 patients including a study group of 139 patients with rotator cuff tears proved by arthroscopy and a control group of 136 patients with arthroscopically intact rotator cuff tendons were reviewed in random order. MR imaging was performed on a 1.0 T system (Magnetom Expert, Siemens). MR arthrograms were analyzed by two radiologists in consensus for articular-sided partial-thickness and full-thickness tears of the supraspinatus, infraspinatus, and subscapularis tendons. At arthroscopy, 197 rotator cuff tears were diagnosed, including 105 partial-thickness (93 supraspinatus, nine infraspinatus, three subscapularis) and 92 full-thickness (43 supraspinatus, 20 infraspinatus, 29 subscapularis) tendon tears. For full-thickness tears, sensitivity, specificity, and accuracy were 96%, 99%, and 98%, respectively, and for partial tears 80%, 97%, and 95%, respectively. False negative and positive assessments in the diagnosis of articular-sided partial-thickness tears were predominantly [78% (35/45)] observed with small articular-sided (Ellman grade1) tendon tears. MR arthrography is highly accurate in the diagnosis of full-thickness rotator cuff tears and is accurate in the diagnosis of articular-sided partial-thickness tears. Limitations in the diagnosis of partial-thickness tears are mainly restricted to small articular-sided tears (Ellman grade 1) due to difficulties in differentiation between fiber tearing, tendinitis, synovitic changes, and superficial fraying at tendon margins. (orig.)

  7. The Relationship Between Intraoperative Tear Dimensions and Postoperative Pain in 1624 Consecutive Arthroscopic Rotator Cuff Repairs.

    Science.gov (United States)

    Yeo, Daniel Y T; Walton, Judie R; Lam, Patrick; Murrell, George A C

    2017-03-01

    Rotator cuff repair often results in significant pain postoperatively, the cause of which is undetermined. Purpose/Hypothesis: The aim of this study was to evaluate the relationship between rotator cuff tear area and postoperative pain in patients who had undergone arthroscopic rotator cuff repair. We hypothesized that larger tears would be more painful because of elevated repair tension at 1 week postoperatively but that smaller tears would be more painful because of a greater healing response, especially from 6 weeks postoperatively. Cohort study; Level of evidence, 3. A total of 1624 patients who underwent arthroscopic rotator cuff repair were included in this study. Exclusion criteria were moderate to severe osteoarthritis, isolated subscapularis repair, calcific tendinitis, synthetic patch repair, revision surgery, and retears on ultrasound at 6 months after surgery. Rotator cuff tears were subdivided into groups based on the tear size and retear rate found for each group. A modified L'Insalata questionnaire was given before surgery and at 1 week, 6 weeks, 3 months, and 6 months after surgery. Pearson and Spearman correlation coefficient tests were performed between rotator cuff tear areas and pain scores. Intraoperative rotator cuff tear areas did not correlate with pain scores preoperatively or at 1 week after surgery. A smaller tear area was associated with more frequent and severe pain with overhead activities, at rest, and during sleep as well as a poorer perceived overall shoulder condition at 6 weeks, 3 months, and 6 months after repair ( r = 0.11-0.23, P 8 cm 2 . There were fewer retears with smaller tears, but they were more painful than large tears postoperatively from 6 weeks to 6 months after surgery. Smaller tears may heal more vigorously, causing more pain. Patients with smaller tears experienced more pain after rotator cuff repair compared with patients with larger tears. These findings are contrary to previous ideas about tear size and

  8. Greenhouse gases study in Amazonia

    International Nuclear Information System (INIS)

    D'Amelio, Monica Tais Siqueira

    2006-01-01

    The Amazon plays an important role on the global carbon cycle, as changing as carbon storage, since Amazon Basin is the biggest area of tropical forest, around 50% of global. Natural's process, deforestation, and use land are CO 2 sources. The Amazon forest is a significant source of N 2 O by soil process, and CH 4 by anaerobic process like flooded areas, rice cultures, and others sources. This project is part of the LBA project (Large-Scale Biosphere Atmosphere Experiment in Amazonia), and this project is 'Vertical profiles of carbon dioxide and other trace gas species over the Amazon basin using small aircraft'. Since December 2000 vertical profiles of CO 2 , CH 4 , CO, H 2 , N 2 O and SF 6 have been measured above central Amazonia. The local sampling was over Tapajos National Forest, a primary forest in Para State, where had a CO 2 flux tower and an east impact area with sources like animals, rice cultivation, biomass burning, etc, to compare the influence of an impact area and a preserved area in the profiles. The Reserva Biologica de Cuieiras, at Amazon State, is the other studied place, where there already exists a CO 2 flux tower, and an east preserved area at this State, to compare with the Cuieiras. The sampling has been carried out on vertical profile from 1000 ft up to 12000 ft using a semi-automated sampling package developed at GMD/NOAA and a small aircraft. The analysis uses the MAGICC system (Multiple Analysis of Gases Influence Climate Change) which is installed at the Atmospheric Chemistry Laboratory (LQA) in IPEN (Instituto de Pesquisas Energeticas e Nucleares). The results showed that all gases studied, except H 2 gas, has been following the global trend. At the Para State, for the studied years, the Amazonian Forest performed as small CO 2 sink. To compare Wet and Dry Seasons, subtracted the Ascension concentration values in the period to remove the global influence. So that, in the 2004 and 2005 wet seasons and 2004 dry season comparison it was

  9. Dipolar quantum gases of erbium

    International Nuclear Information System (INIS)

    Frisch, A.

    2014-01-01

    Since the preparation of the first Bose-Einstein condensate about two decades ago and the first degenerate Fermi gas following four years later a plethora of fascinating quantum phenomena have been explored. The vast majority of experiments focused on quantum degenerate atomic gases with short-range contact interaction between particles. Atomic species with large magnetic dipole moments, such as chromium, dysprosium, and erbium, offer unique possibilities to investigate phenomena arising from dipolar interaction. This kind of interaction is not only long-range but also anisotropic in character and imprints qualitatively novel features on the system. Prominent examples are the d-wave collapse of a dipolar Bose-Einstein condensate of chromium atoms realized by the group in Stuttgart, the spin magnetization and demagnetization dynamics observed by groups in Stuttgart, Paris, and Stanford, and the deformation of the Fermi surface observed by our group in Innsbruck. This thesis reports on the creation and study of the first Bose-Einstein condensate and degenerate Fermi gas of erbium atoms. Erbium belongs to the lanthanide group of elements and has a large magnetic moment of seven Bohr magneton. In particular, this thesis describes the experimental apparatus and the sequence for producing a dipolar quantum gas. There is an emphasis on the production of the narrow-line magneto-optical trap of erbium since this represents a very efficient and robust laser-cooling scheme that greatly simplifies the experimental procedure. After describing the experimental setup this thesis focuses on several fundamental questions related to the dipolar character of erbium and to its lanthanide nature. A first set of studies centers on the scattering properties of ultracold erbium atoms, including the elastic and the inelastic cross section and the spectrum of Feshbach resonances. Specifically, we observe that identical dipolar fermions do collide and rethermalize even at low temperatures

  10. ProTec Tear-Offs: A Preliminary Assessment

    International Nuclear Information System (INIS)

    Peeler, D

    2005-01-01

    The Savannah River National Laboratory (SRNL) has conducted a series of ''scoping'' tests (referred to as Phase 1) to assess the potential use of a Mylar(reg s ign) tear-off system as a primary or secondary protective barrier to minimize acid etching (''frosting''), accidental scratching, and/or radiation damage for shielded cells windows. Conceptually, thin, multi-layered sheets of Mylar (referred to as a ''tear-off'' system) could be directly applied to the Lexan(reg s ign) sheet or glovebox/hood sash window to serve as a secondary (or primary) barrier. Upon degradation of visual clarity due to accidental scratching, spills/splatters, and/or radiation damage, the outer layer (or sheet) of Mylar could be removed ''refreshing'' or restoring the view. Due to the multi-layer aspect, the remaining Mylar layers would provide continued protection for the window from potential reoccurrences (which could be immediate or after some extended time period). Although the concept of using a tear-off system as a protective barrier was conceptually enticing, potential technical issues were identified and addressed as part of this Phase 1 feasibility study. These included resistance to: (1) acid(s) (concentrated (28.9 M) HF, concentrated (15.9M) HNO 3 , 6M HCl, and 0.6M H 3 BO 3 ), (2) base (a simulated sludge with pH of 12.9), (3) gamma radiation (cumulative dose of ∼200,000 rad), and (4) scratch resistance (simulating accidental scratching with the manipulators). Not only can these four factors play a significant role in determining the visual clarity of the integrated system, they can also contribute to the mechanical integrity issues which could dictate the ability to remove the outer layer when visual clarity has degraded. The results of the Phase 1 study clearly indicate that the Mylar tear-off concept (as a primary or secondary protective barrier) is a potential technical solution to prevent or retard excessive damage that would result from acid etching, base damage (as a

  11. Thermodynamics of ultracold Fermi gases

    International Nuclear Information System (INIS)

    Nascimbene, Sylvain

    2010-01-01

    Complex Hamiltonians from condensed matter, such as the Fermi-Hubbard model, can be experimentally studied using ultracold gases. This thesis describes a new method for determining the equation of state of an ultracold gas, making the comparison with many-body theories straightforward. It is based on the measurement of the local pressure inside a trapped gas from the analysis of its in situ image. We first apply this method to the study of a Fermi gas with resonant interactions, a weakly-interacting 7 Li gas acting as a thermometer. Surprisingly, none of the existing many-body theories of the unitary gas accounts for the equation of state deduced from our study over its full range. The virial expansion extracted from the high-temperature data agrees with the resolution of the three-body problem. At low temperature, we observe, contrary to some previous studies, that the normal phase behaves as a Fermi liquid. Finally we obtain the critical temperature for superfluidity from a clear signature on the equation of state. We also measure the pressure of the ground state as a function of spin imbalance and interaction strength - measure directly relevant to describe the crust of neutron stars. Our data validate Monte-Carlo simulations and quantify the Lee-Huang-Yang corrections to mean-field interactions in low-density fermionic or bosonic superfluids. We show that, in most cases, the partially polarized normal phase can be described as a Fermi liquid of polarons. The polaron effective mass extracted from the equation of state is in agreement with a study of collective modes. (author)

  12. Rare gases in Samoan xenoliths

    Science.gov (United States)

    Poreda, R. J.; Farley, K. A.

    1992-09-01

    The rare gas isotopic compositions of residual harzburgite xenoliths from Savai'i (SAV locality) and an unnamed seamount south of the Samoan chain (PPT locality) provide important constraints on the rare gas evolution of the mantle and atmosphere. Despite heterogeneous trace element compositions, the rare gas characteristics of the xenoliths from each of the two localities are strikingly similar. SAV and PPT xenoliths have 3He/ 4He ratios of11.1 ± 0.5 R A and21.6 ± 1 R A, respectively; this range is comparable to the 3He/ 4He ratios in Samoan lavas and clearly demonstrates that they have trapped gases from a relatively undegassed reservoir. The neon results are not consistent with mixing between MORB and a plume source with an atmospheric signature. Rather, the neon isotopes reflect either a variably degassed mantle (with a relative order of degassing of Loihi Honda et al. that the 20Ne/ 22Ne ratio in the mantle more closely resembles the solar ratio than the atmospheric one. 40Ar/ 36Ar ratios in the least contaminated samples range from 4,000 to 12,000 with the highest values in the 22 RA PPT xenoliths. There is no evidence for atmospheric 40Ar/ 36Ar ratios in the mantle source of these samples, which indicates that the lower mantle may have 40Ar/ 36Ar ratios in excess of 5,000. Xenon isotopic anomalies in 129Xe and 136Xe are as high as 6%, or about half of the maximum MORB excess and are consistent with the less degassed nature of the Samoan mantle source. These results contradict previous suggestions that the high 3He/ 4He mantle has a near-atmospheric heavy rare gas isotopic composition.

  13. Diagnostic accuracy of 3T conventional shoulder MRI in the detection of the long head of the biceps tendon tears associated with rotator cuff tendon tears

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ro Woon; Choi, Soo-Jung; Ahn, Jae Hong; Shin, Dong Rock; Kang, Chae Hoon [University of Ulsan, College of Medicine, Department of Radiology, Asan Foundation, Gangneung Asan Hospital, Gangneung-si, Gangwon-do (Korea, Republic of); Lee, Man Ho [Andong Medical Center, Department of Radiology, Andong-si, Gyeongsangbuk-do (Korea, Republic of); Lee, Ki Won [University of Ulsan, College of Medicine, Department of Orthopedic Surgery, Asan Foundation, Gangneung Asan Hospital, Gangneung-si, Gangwon-do (Korea, Republic of)

    2016-12-15

    To evaluate the diagnostic performance (DP) of 3T (3 Tesla field strength) conventional shoulder magnetic resonance imaging (MRI) in detecting the long head of the biceps tendon (LHBT) tears in association with rotator cuff tendon tears. This study included 80 consecutive patients who underwent arthroscopic surgery for rotator cuff tendon tears. Two radiologists independently evaluated the preoperative 3T shoulder MRI for the presence of LHBT tears. The DP of MRI was evaluated using the results of arthroscopy as the reference standard. We also evaluated the DP of several MR signs of LHBT in detection of partial LHBT tears. Arthroscopic examination revealed 35 partial and 5 complete tears. According to the results of evaluation by reviewers 1 and 2, shoulder MRI exhibited sensitivities of 77.14 and 80 % and specificities of 71.11 and 73.33 % in detection of partial LHBT tears and sensitivities of 80 and 100 % and a specificity of 100% (both) in detection of complete LHBT tears. In detecting partial LHBT tears, increased T2 signal intensity of the LHBT exhibited high sensitivities (reviewers 1 and 2; 82.85 and 80 %, respectively) and the presence of intratendinous defects or C-signs exhibited the highest specificities (reviewers 1 and 2; 95.55 and 93.33 %, respectively), followed by abnormalities in shape and outer margins of the LHBT (reviewers 1 and 2; 91.11 and 82 %; 91.11 and 86.66 %, respectively). Non-contrast-enhanced 3T shoulder MRI is potentially highly accurate in detection of complete LHBT tears, but moderately accurate in detection of partial LHBT tears. (orig.)

  14. Diagnostic accuracy of 3T conventional shoulder MRI in the detection of the long head of the biceps tendon tears associated with rotator cuff tendon tears

    International Nuclear Information System (INIS)

    Lee, Ro Woon; Choi, Soo-Jung; Ahn, Jae Hong; Shin, Dong Rock; Kang, Chae Hoon; Lee, Man Ho; Lee, Ki Won

    2016-01-01

    To evaluate the diagnostic performance (DP) of 3T (3 Tesla field strength) conventional shoulder magnetic resonance imaging (MRI) in detecting the long head of the biceps tendon (LHBT) tears in association with rotator cuff tendon tears. This study included 80 consecutive patients who underwent arthroscopic surgery for rotator cuff tendon tears. Two radiologists independently evaluated the preoperative 3T shoulder MRI for the presence of LHBT tears. The DP of MRI was evaluated using the results of arthroscopy as the reference standard. We also evaluated the DP of several MR signs of LHBT in detection of partial LHBT tears. Arthroscopic examination revealed 35 partial and 5 complete tears. According to the results of evaluation by reviewers 1 and 2, shoulder MRI exhibited sensitivities of 77.14 and 80 % and specificities of 71.11 and 73.33 % in detection of partial LHBT tears and sensitivities of 80 and 100 % and a specificity of 100% (both) in detection of complete LHBT tears. In detecting partial LHBT tears, increased T2 signal intensity of the LHBT exhibited high sensitivities (reviewers 1 and 2; 82.85 and 80 %, respectively) and the presence of intratendinous defects or C-signs exhibited the highest specificities (reviewers 1 and 2; 95.55 and 93.33 %, respectively), followed by abnormalities in shape and outer margins of the LHBT (reviewers 1 and 2; 91.11 and 82 %; 91.11 and 86.66 %, respectively). Non-contrast-enhanced 3T shoulder MRI is potentially highly accurate in detection of complete LHBT tears, but moderately accurate in detection of partial LHBT tears. (orig.)

  15. Verification of gyrokinetic particle simulation of current-driven instability in fusion plasmas. II. Resistive tearing mode

    International Nuclear Information System (INIS)

    Liu, Dongjian; Zhang, Wenlu; McClenaghan, Joseph; Wang, Jiaqi; Lin, Zhihong

    2014-01-01

    Global gyrokinetic particle simulation of resistive tearing modes has been developed and verified in the gyrokinetic toroidal code (GTC). GTC linear simulations in the fluid limit of the kink-tearing and resistive tearing modes in the cylindrical geometry agree well with the resistive magnetohydrodynamic eigenvalue and initial value codes. Ion kinetic effects are found to reduce the radial width of the tearing modes. GTC simulations of the resistive tearing modes in the toroidal geometry find that the toroidicity reduces the growth rates

  16. Anaesthetic gases: environmental impact and alternatives

    African Journals Online (AJOL)

    Little consideration has been given to the environmental impact of anaesthetic gas .... our practice to select gases with a lower environmental impact is also ... is used as raw material for new anaesthetics. ... none in the pipeline.1. Conclusion.

  17. Voluntary reporting of greenhouse gases, 1995

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-07-01

    The Voluntary Reporting Program for greenhouse gases is part of an attempt by the U.S. Government to develop innovative, low-cost, and nonregulatory approaches to limit emissions of greenhouse gases. It is one element in an array of such programs introduced in recent years as part of the effort being made by the United States to comply with its national commitment to stabilize emissions of greenhouse gases under the Framework Convention on Climate Change. The Voluntary Reporting Program, developed pursuant to Section 1605(b) of the Energy Policy Act of 1992, permits corporations, government agencies, households, and voluntary organizations to report to the Energy Information Administration (EIA) on actions taken that have reduced or avoided emissions of greenhouse gases.

  18. Granular Gases: Probing the Boundaries of Hydrodynamics

    International Nuclear Information System (INIS)

    Goldhirsch, I.

    1999-01-01

    The dissipative nature of the particle interactions in granular systems renders granular gases mesoscopic and bearing some similarities to regular gases in the ''continuum transition regime'' where shear rates and/or thermal gradients are very large). The following properties of granular gases support the above claim: (i). Mean free times are of the same order as macroscopic time scales (inverse shear rates); (ii). Mean free paths can be macroscopic and comparable to the system's dimensions; (iii). Typical flows are supersonic; (iv). Shear rates are typically ''large''; (v). Stress fields are scale (resolution) dependent; (vi). Burnett and super-Burnett corrections to both the constitutive relations and the boundary conditions are of importance; (vii). Single particle distribution functions can be far from Gaussian. It is concluded that while hydrodynamic descriptions of granular gases are relevant, they are probing the boundaries of applicability of hydrodynamics and perhaps slightly beyond

  19. Greenhouse gases - observed tendencies contra scenarios

    International Nuclear Information System (INIS)

    Groenaas, Sigbjoern

    2006-01-01

    The article presents a study of the increase in greenhouse gases and concludes that it will be necessary to substantially reduce the CO2 concentrations in the atmosphere in order to avoid serious climatic changes

  20. Climate Change, Greenhouse Gases and Aerosols

    Indian Academy of Sciences (India)

    user

    their radiative properties are similar to the glass used in a green- house. Greenhouse gases in the Earth's atmosphere absorb 90% of the radiation emitted .... and wind speed and direction in each box is calculated using the physical laws gov-.

  1. Roadside management strategies to reduce greenhouse gases.

    Science.gov (United States)

    2010-06-01

    Californias Global Warming Solutions Act of 2006 (AB 32), Sustainable Communities and Climate Protection Act : (SB 375), and Executive Order S-14-08 direct Caltrans to develop actions to reduce greenhouse gases (GHGs). Air : pollution reduction is...

  2. Gases for an SSC muon detector

    International Nuclear Information System (INIS)

    Christophorou, L.G.; Datskos, P.G.; Carter, J.G.; Tennessee Univ., Knoxville, TN

    1990-01-01

    Recent measurements of electron drift velocities as a function of the density-reduced electric field E/N are reported for a number of unitary gases and the mixtures CO 2 /CH 4 and NH 3 /CF 4 /Ar. Calculated values of the mean electron energy as a function of E/N are also reported for unitary gases and mixtures of CO 2 /CH 4 . 7 refs., 5 figs

  3. Flux Jacobian Matrices For Equilibrium Real Gases

    Science.gov (United States)

    Vinokur, Marcel

    1990-01-01

    Improved formulation includes generalized Roe average and extension to three dimensions. Flux Jacobian matrices derived for use in numerical solutions of conservation-law differential equations of inviscid flows of ideal gases extended to real gases. Real-gas formulation of these matrices retains simplifying assumptions of thermodynamic and chemical equilibrium, but adds effects of vibrational excitation, dissociation, and ionization of gas molecules via general equation of state.

  4. Pseudogap phenomena in ultracold atomic Fermi gases

    OpenAIRE

    Chen, Qijin; Wang, Jibiao

    2014-01-01

    The pairing and superfluid phenomena in a two-component ultracold atomic Fermi gas is an analogue of Cooper pairing and superconductivity in an electron system, in particular, the high $T_c$ superconductors. Owing to the various tunable parameters that have been made accessible experimentally in recent years, atomic Fermi gases can be explored as a prototype or quantum simulator of superconductors. It is hoped that, utilizing such an analogy, the study of atomic Fermi gases may shed light to ...

  5. Comparative studies of MRI and operative findings in rotator cuff tear

    International Nuclear Information System (INIS)

    Yamakawa, Seigo; Ichikawa, Norikazu; Itadera, Eichi; Hashizume, Hiroyuki; Inoue, Hajime

    2001-01-01

    A prospective study was performed to determine the accuracy of magnetic resonance imaging (MRI) compared with operative findings in the evaluation of patients associated with rotator cuff tears. Fifty-four of 60 shoulders (58 patients) examined by MRI were confirmed as full-thickness tears and 6 as partial-thickness tears at the time of surgery. The oblique coronal, oblique sagittal, and axial planes of T2-weighted images with the 0.5 tesla MRI system were obtained preoperatively and compared with operative findings. MRI correctly identified 46 of 54 full-thickness rotator cuff tears and 5 of 6 partial-thickness tears. A comparison of MRI and operative findings in full-thickness cuff tears showed a sensitivity of 85%, a specificity of 83%, and a positive prospective value (PPV) of 99%. A comparison of partial-thickness tears showed a sensitivity of 83%, a specificity of 85%, and PPV of 39%. Linear regression analysis showed an excellent correlation between the MRI assessment and measurement at the time of surgery (r=0.90, P<0.01). MRI was useful in evaluating large and medium-sized rotator cuff tears, but less useful in distinguishing small full-thickness tears from partial-thickness tears. (author)

  6. Emotional tears facilitate the recognition of sadness and the perceived need for social support.

    Science.gov (United States)

    Balsters, Martijn J H; Krahmer, Emiel J; Swerts, Marc G J; Vingerhoets, Ad J J M

    2013-02-12

    The tearing effect refers to the relevance of tears as an important visual cue adding meaning to human facial expression. However, little is known about how people process these visual cues and their mediating role in terms of emotion perception and person judgment. We therefore conducted two experiments in which we measured the influence of tears on the identification of sadness and the perceived need for social support at an early perceptional level. In two experiments (1 and 2), participants were exposed to sad and neutral faces. In both experiments, the face stimuli were presented for 50 milliseconds. In experiment 1, tears were digitally added to sad faces in one condition. Participants demonstrated a significant faster recognition of sad faces with tears compared to those without tears. In experiment 2, tears were added to neutral faces as well. Participants had to indicate to what extent the displayed individuals were in need of social support. Study participants reported a greater perceived need for social support to both sad and neutral faces with tears than to those without tears. This study thus demonstrated that emotional tears serve as important visual cues at an early (pre-attentive) level.

  7. Two types of peak emotional responses to music: The psychophysiology of chills and tears

    Science.gov (United States)

    Mori, Kazuma; Iwanaga, Makoto

    2017-01-01

    People sometimes experience a strong emotional response to artworks. Previous studies have demonstrated that the peak emotional experience of chills (goose bumps or shivers) when listening to music involves psychophysiological arousal and a rewarding effect. However, many aspects of peak emotion are still not understood. The current research takes a new perspective of peak emotional response of tears (weeping, lump in the throat). A psychophysiological experiment showed that self-reported chills increased electrodermal activity and subjective arousal whereas tears produced slow respiration during heartbeat acceleration, although both chills and tears induced pleasure and deep breathing. A song that induced chills was perceived as being both happy and sad whereas a song that induced tears was perceived as sad. A tear-eliciting song was perceived as calmer than a chill-eliciting song. These results show that tears involve pleasure from sadness and that they are psychophysiologically calming; thus, psychophysiological responses permit the distinction between chills and tears. Because tears may have a cathartic effect, the functional significance of chills and tears seems to be different. We believe that the distinction of two types of peak emotions is theoretically relevant and further study of tears would contribute to more understanding of human peak emotional response. PMID:28387335

  8. Behavioral and neural responses to infant and adult tears: The impact of maternal love withdrawal.

    Science.gov (United States)

    Riem, Madelon M E; van IJzendoorn, Marinus H; De Carli, Pietro; Vingerhoets, Ad J J M; Bakermans-Kranenburg, Marian J

    2017-09-01

    The current study examined behavioral and neural responses to infant and adult tears, taking into account childhood experiences with parental love-withdrawal. With functional MRI (fMRI), we measured neural reactivity to pictures of infants and adults with and without tears on their faces in nulliparous women with varying childhood experiences of maternal use of love withdrawal. Behavioral responses to infant and adult tears were measured with an approach-avoidance task. We found that individuals with experiences of love withdrawal showed less amygdala and insula reactivity to adult tears, but love withdrawal did not affect amygdala and insula reactivity to infant tears. During the approach-avoidance task, individuals responded faster to adult tears in the approach condition compared with the avoidance condition, indicating that adult tears facilitate approach behavior. Individuals responded faster to infant tears than to adult tears, regardless of approach or avoidance condition. Our findings suggest that infant tears are highly salient and may, therefore, overrule the effects of contextual and personal characteristics that influence the perception of adult crying. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  9. Two types of peak emotional responses to music: The psychophysiology of chills and tears.

    Science.gov (United States)

    Mori, Kazuma; Iwanaga, Makoto

    2017-04-07

    People sometimes experience a strong emotional response to artworks. Previous studies have demonstrated that the peak emotional experience of chills (goose bumps or shivers) when listening to music involves psychophysiological arousal and a rewarding effect. However, many aspects of peak emotion are still not understood. The current research takes a new perspective of peak emotional response of tears (weeping, lump in the throat). A psychophysiological experiment showed that self-reported chills increased electrodermal activity and subjective arousal whereas tears produced slow respiration during heartbeat acceleration, although both chills and tears induced pleasure and deep breathing. A song that induced chills was perceived as being both happy and sad whereas a song that induced tears was perceived as sad. A tear-eliciting song was perceived as calmer than a chill-eliciting song. These results show that tears involve pleasure from sadness and that they are psychophysiologically calming; thus, psychophysiological responses permit the distinction between chills and tears. Because tears may have a cathartic effect, the functional significance of chills and tears seems to be different. We believe that the distinction of two types of peak emotions is theoretically relevant and further study of tears would contribute to more understanding of human peak emotional response.

  10. MRI diagnosis of ACL bundle tears: value of oblique axial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ng, Alex W.H.; Griffith, James F.; Hung, Esther H.Y. [Chinese University of Hong Kong, Department of Imaging and Interventional Radiology, Prince of Wales Hospital, Shatin, NT, Hong Kong SAR (China); Law, Kan Yip; Yung, Patrick S.H. [Chinese University of Hong Kong, Department of Orthopedics and Traumatology, Prince of Wales Hospital, Shatin, NT, Hong Kong SAR (China)

    2013-02-15

    To investigate the diagnostic accuracy of oblique axial intermediate weighting MR imaging in detecting partial thickness anterior cruciate ligament (ACL) bundle tears. The study protocol was approved by the institutional ethics committee. Sixty-one subjects (43 male, 18 female; mean age 27.4 years; range 9 to 57 years) with clinically suspected ACL tear or meniscal tear between September 2009 and January 2011 were studied with MRI and arthroscopy. Detection of partial tear for the ACL as a whole and for each ACL bundle by protocol A (standard orthogonal sequences) and protocol B (standard orthogonal sequences plus oblique axial intermediate weighted imaging) was compared in a blinded fashion. Performance characteristics for protocol A and protocol B were compared using sensitivity, specificity, accuracy and ROC curves. A two-tailed p value of <0.05 indicated statistical significance. Fifteen (24.6%) normal, 15 (24.6%) partial and 31 complete tears were diagnosed by arthroscopy. Sensitivity, specificity and accuracy of protocol A for the diagnosis of partial tear of the ACL was 33%, 87% and 74%, while for protocol B the values were 87%, 87% and 87% respectively. The area under the curve (AUC) for the diagnosis of partial ACL tear and individual bundle tear was higher for protocol B, although this difference did not reach statistical significance (p > 0.05). The addition of oblique axial imaging to standard MR imaging improves diagnostic accuracy for detecting partial tears of the ACL as well as individual bundle tears of the ACL. (orig.)

  11. A review of patient and skin characteristics associated with skin tears.

    Science.gov (United States)

    Rayner, R; Carville, K; Leslie, G; Roberts, P

    2015-09-01

    Skin tears are the most common wound among the elderly and have the potential to cause infection, form chronic wounds, reduce quality of life and increase health-care costs. Our aim was to identify studies that reviewed patient and skin characteristics associated with skin tears. A review of skin tear studies reported in the English literature between 1980 and 2013 was undertaken using the following electronic databases: PubMed, Medline, CINAHL, Embase, Scopus, Evidence Based and Medicine Reviews (EBM). Search terms included aged, skin, tears or lacerations, skin tearing, geri tear, epidermal tear and prevalence. There were 343 articles found with using the search terms. After abstract review nine were found to be relevant to the search. The principle findings from these eight published articles and one unpublished study revealed that the most common patient characteristics were a history of skin tears, impaired mobility and impaired cognition. Skin characteristics associated with skin tears included senile purpura, ecchymosis and oedema. This review provides an overview of identified patient and skin characteristics that predispose the elderly to skin tears and exposes the lack of research within this domain. R. Rayner is a recipient of a 2013 Australian Postgraduate Award, Curtin University Postgraduate Scholarship and a Wound Management Cooperative Research Centre (CRC) PhD stipend. The School of Nursing, Midwifery and Paramedicine, Curtin University and the Silver Chain Group, Western Australia are participants in the Wound Management Innovation CRC. No conflict of interest exists among the authors.

  12. Tearing instability in a tokamak with a noncircular cross section

    Energy Technology Data Exchange (ETDEWEB)

    Arsenin, V. V., E-mail: arsenin-vv@nrcki.ru; Skovoroda, A. A., E-mail: skovoroda-aa@nrcki.ru [National Research Center Kurchatov Institute (Russian Federation)

    2016-12-15

    Using a straight-column model to describe tokamak plasma with a noncircular cross section, it is shown how to (i) find the boundary of tearing instability from the condition of existence of a magnetohydrodynamic plasma equilibrium different from that of a straight cylinder by solving a two-dimensional linear boundary-value problem with a second-order equation with respect to the flux coordinate and (ii) find the spatial structure of the tearing mode and the corresponding effective Δ' when there is only one resonance magnetic surface in the plasma for a given axial wavenumber by solving some kind of a boundary-value problem for the perturbation. The proposed approach is illustrated by numerical calculations for the case of an elliptical cross section as an example.

  13. I.S.Mu.L.T - Rotator Cuff Tears Guidelines

    Science.gov (United States)

    Oliva, Francesco; Piccirilli, Eleonora; Bossa, Michela; Via, Alessio Giai; Colombo, Alessandra; Chillemi, Claudio; Gasparre, Giuseppe; Pellicciari, Leonardo; Franceschetti, Edoardo; Rugiero, Clelia; Scialdoni, Alessandro; Vittadini, Filippo; Brancaccio, Paola; Creta, Domenico; Buono, Angelo Del; Garofalo, Raffaele; Franceschi, Francesco; Frizziero, Antonio; Mahmoud, Asmaa; Merolla, Giovanni; Nicoletti, Simone; Spoliti, Marco; Osti, Leonardo; Padulo, Johnny; Portinaro, Nicola; Tajana, Gianfranco; Castagna, Alex; Foti, Calogero; Masiero, Stefano; Porcellini, Giuseppe; Tarantino, Umberto; Maffulli, Nicola

    2015-01-01

    Despite the high level achieved in the field of shoulder surgery, a global consensus on rotator cuff tears management is lacking. This work is divided into two main sessions: in the first, we set questions about hot topics involved in the rotator cuff tears, from the etiopathogenesis to the surgical treatment. In the second, we answered these questions by mentioning Evidence Based Medicine. The aim of the present work is to provide easily accessible guidelines: they could be considered as recommendations for a good clinical practice developed through a process of systematic review of the literature and expert opinion, in order to improve the quality of care and rationalize the use of resources. PMID:26958532

  14. The role of biomaterials in the treatment of meniscal tears

    Directory of Open Access Journals (Sweden)

    Crystal O. Kean

    2017-11-01

    Full Text Available Extensive investigations over the recent decades have established the anatomical, biomechanical and functional importance of the meniscus in the knee joint. As a functioning part of the joint, it serves to prevent the deterioration of articular cartilage and subsequent osteoarthritis. To this end, meniscus repair and regeneration is of particular interest from the biomaterial, bioengineering and orthopaedic research community. Even though meniscal research is previously of a considerable volume, the research community with evolving material science, biology and medical advances are all pushing toward emerging novel solutions and approaches to the successful treatment of meniscal difficulties. This review presents a tactical evaluation of the latest biomaterials, experiments to simulate meniscal tears and the state-of-the-art materials and strategies currently used to treat tears.

  15. Deformation behavior of curling strips on tearing tubes

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Ji Won; Kwon, Tae Soo; Jung, Hyun Seung; Kim, Jin Sung [Dept. of Robotics and Virtual Engineering, Korea University of Science and Technology, Seoul (Korea, Republic of)

    2015-10-15

    This paper discusses the analysis of the curl deformation behavior when a dynamic force is applied to a tearing tube installed on a flat die to predict the energy absorption capacity and deformation behavior. The deformation of the tips of the curling strips was obtained when the curl tips and tube body are in contact with each other, and a formula describing the energy dissipation rate caused by the deformation of the curl tips is proposed. To improve this formula, we focused on the variation of the curl radius and the reduced thickness of the tube. A formula describing the mean curl radius is proposed and verified using the curl radius measurement data of collision test specimens. These improved formulas are added to the theoretical model previously proposed by Huang et al. and verified from the collision test results of a tearing tube.

  16. The growth of the tearing mode - Boundary and scaling effects

    Science.gov (United States)

    Steinolfson, R. S.; Van Hoven, G.

    1983-01-01

    A numerical model of resistive magnetic tearing is developed in order to verify and relate the results of the principal approximations used in analytic analyses and to investigate the solutions and their growth-rate scalings over a large range of primary parameters which include parametric values applicable to the solar atmosphere. The computations cover the linear behavior for a variety of boundary conditions, emphasizing effects which differentiate magnetic tearing in astrophysical situations from that in laboratory devices. Eigenfunction profiles for long and short wavelengths are computed and the applicability of the 'constant psi' approximation is investigated. The growth rate is computed for values of the magnetic Reynolds number up to a trillion and of the dimensionless wavelength parameter down to 0.001. The analysis predicts significant effects due to differing values of the magnetic Reynolds number.

  17. Influence of toroidal rotation on resistive tearing modes in tokamaks

    International Nuclear Information System (INIS)

    Wang, S.; Ma, Z. W.

    2015-01-01

    Influence of toroidal equilibrium plasma rotation on m/n = 2/1 resistive tearing modes is studied numerically using a 3D toroidal MHD code (CLT). It is found that the toroidal rotation with or without shear can suppress the tearing instability and the Coriolis effect in the toroidal geometry plays a dominant role on the rotation induced stabilization. For a high viscosity plasma (τ R /τ V  ≫ 1, where τ R and τ V represent resistive and viscous diffusion time, respectively), the effect of the rotation shear combined with the viscosity appears to be stabilizing. For a low viscosity plasmas (τ R /τ V  ≪ 1), the rotation shear shows a destabilizing effect when the rotation is large

  18. Influence of toroidal rotation on resistive tearing modes in tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Wang, S.; Ma, Z. W., E-mail: zwma@zju.edu.cn [Institute for Fusion Theory and Simulation, Zhejiang University, Hangzhou 310027 (China)

    2015-12-15

    Influence of toroidal equilibrium plasma rotation on m/n = 2/1 resistive tearing modes is studied numerically using a 3D toroidal MHD code (CLT). It is found that the toroidal rotation with or without shear can suppress the tearing instability and the Coriolis effect in the toroidal geometry plays a dominant role on the rotation induced stabilization. For a high viscosity plasma (τ{sub R}/τ{sub V} ≫ 1, where τ{sub R} and τ{sub V} represent resistive and viscous diffusion time, respectively), the effect of the rotation shear combined with the viscosity appears to be stabilizing. For a low viscosity plasmas (τ{sub R}/τ{sub V} ≪ 1), the rotation shear shows a destabilizing effect when the rotation is large.

  19. Effects of toroidal coupling on the stability of tearing modes

    International Nuclear Information System (INIS)

    Carreras, B.; Hicks, H.R.; Lee, D.K.

    1980-06-01

    The time evolution of tearing modes in toroidal geometry is studied in the low-β and large aspect ratio limit. An initial value three-dimensional computer code, which numerically advances the reduced set of resistive magnetohydrodynamic equations is employed. Toroidicity has, in general, a destabilizing effect on tearing modes in this limit. A generalization of the Δ' formalism can be used to study the linear regime. The results obtained in this way are in very good agreement with the results from the initial value code. The nonlinear phase of the evolution is also followed numerically. In the case of strong interaction of different helicities, a larger region of stochastic magnetic field lines results than in the cylindrical geometry case

  20. Proteases, proteolysis and inflammatory molecules in the tears of people with keratoconus.

    Science.gov (United States)

    Balasubramanian, Sivaraman Arumugam; Mohan, Sujatha; Pye, David Cecil; Willcox, Mark Duncan Perry

    2012-06-01

    To investigate the expression of proteases, proteolytic activity and cytokines in the tear film of people with keratoconus. Basal tears from people with keratoconus, from individuals who had undergone corneal collagen cross-linking for the treatment of keratoconus, and from normal controls were collected using a capillary tube. Corneal curvature of each subject was mapped. The total protein in tears was estimated. Levels and activity of proteases in the tears were analysed using specific antibody arrays and activity assays. The total tear protein level was significantly reduced in keratoconus (4.1 ± 0.9 mg/ml) compared with normals (6.7 ± 1.4 mg/ml) (p tear expression of matrix metalloproteinases (MMP) -1, -3, -7, -13, interleukins (IL) -4, -5, -6, -8 and tumour necrosis factor (TNF) -α, -β were evident in keratoconus. Tear IL-6 was the only cytokine significantly (p tears of keratoconus subjects compared with the collagen cross-linked group. No significant difference in tear proteases were observed between the normal and the cross-linked groups, although the expression of TNF-α was significantly (p tears from keratoconus compared with normal subjects. The activity of tear gelatinases (69.6 ± 22.2 FIU) and collagenases (5.7 ± 3.3 FIU) in the collagen cross-linked group was not significantly different compared with either keratoconus or normals. Tears of people with keratoconus had 1.9 times higher levels of proteolytic activity and over expression of several MMPs and cytokines compared with tears from controls. Further investigations are required to study the possible implications of these changes and whether they can be used to monitor disease progression or determine the success of corneal collagen cross-linking. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.

  1. Analysis of electron interactions in dielectric gases

    International Nuclear Information System (INIS)

    Olivet, Aurelio; Duque, Daniel; Vega, Lourdes F.

    2007-01-01

    We present and discuss results concerning electron interactions processes of dielectric gases and their relationship with the macroscopic behavior of these gases, in particular, with their dielectric strength. Such analysis is based on calculating energies of reactions for molecular ionization, dissociative ionization, parent negative ion formation, and dissociative electron attachment processes. We hypothesize that the estimation of the required energy for a reduced number of processes that take place in electrically stressed gases could be related to the gas' capability to manage the electron flow during an electrical discharge. All calculations were done with semiempirical quantum chemistry methods, including an initial optimization of molecular geometry and heat of formation of the dielectric gases and all of species that appear during electron interaction reactions. The performance of semiempirical methods Austin model 1 and Parametric model 3 (PM3) was compared for several compounds, PM3 being superior in most cases. Calculations performed for a sample of nine dielectric gases show that electron attachment and detachment processes occur in different energy bands that do not overlap for any value of the dielectric strength. We have also analyzed the relationship between dielectric strength and two physical properties: electron affinity and ionization energy. Calculations performed for 43 dielectric gases show no clear correlation between them, although certain guidelines for the qualitative estimation of dielectric strength can still be assessed

  2. Gases and carbon in metals. Pt. 14

    International Nuclear Information System (INIS)

    Jehn, H.; Speck, H.; Hehn, W.; Fromm, E.; Hoerz, G.

    1981-01-01

    This issue is part of a series of data on 'Gases and Carbon in Metals' which supplements the data compilation in the book 'Gase und Kohlenstoff in Metallen' (Gases and Carbon in Metals), edited by E. Fromm and E. Gebhardt, Springer-Verlag, Berlin 1976. The present survey includes results from papers published after the copy deadline and recommends critically selected data. Furthermore, it comprises a bibliography of relevant literature. For each element, firstly data on binary systems are presented, starting with hydrogen and followed by carbon, nitrogen, oxygen, and rare gases. Within one metal-metalloid system the data are listed under topics such as solubility, solubility limit, dissociation pressure of compounds, vapour pressure of volatile oxides, thermodynamic data, diffusion, transport parameters (effective valence, heat of transport), permeation of gases through metals, gas absorption and gas desorption kinetics, compound formation kinetics, precipitation kinetics, and property changes. Following the data on binary systems, the data of ternary systems are presented, beginning with systems which contain one metal and two gases or one gas and carbon and continuing with systems with two metals and one gas or carbon. (orig./GE)

  3. Adsorption of human tear lipocalin to human meibomian lipid films.

    Science.gov (United States)

    Millar, Thomas J; Mudgil, Poonam; Butovich, Igor A; Palaniappan, Chendur K

    2009-01-01

    Tear lipocalin (Tlc) is a major lipid binding protein in tears and is thought to have an important role in stabilizing the Meibomian lipid layer by transferring lipids to it from the aqueous layer or ocular surface, or by adsorbing to it directly. These possible roles have been investigated in vitro using human Tlc. Tlc was purified from human tears by size exclusion chromatography followed by ion exchange chromatography. Three additional samples of the Tlc were prepared by lipidation, delipidation, and relipidation. The lipids extracted from the purified Tlc were analyzed by HPLC-MS followed by fragmentation. Adsorption of these different forms of Tlc to a human Meibomian lipid film spread on the surface of an artificial tear buffer in a Langmuir trough were observed by recording changes in the pressure with time (Pi-T profile) and monitoring the appearance of the film microscopically. These results were compared with similar experiments using a bovine Meibomian lipid film. The results indicated that Tlc binds slowly to a human Meibomian lipid film compared with lysozyme or lactoferrin, even at 37 degrees C. The adsorption of Tlc to a human Meibomian lipid film was very different from its adsorption to a bovine Meibomian lipid film, indicating the nature of the lipids in the film is critical to the adsorption process. Similarly, the different forms of Tlc had quite distinct adsorption patterns, as indicated both by changes in Pi-T profiles and the microscopic appearance of the films. It was concluded that human Tlc was capable of adsorbing to and penetrating into a Meibomian lipid layer, but this process is very complex and depends on both the types of lipids bound to Tlc and the lipid complement comprising the Meibomian lipid film.

  4. Adsorption of Human Tear Lipocalin to Human Meibomian Lipid Films

    Science.gov (United States)

    Millar, Thomas J.; Mudgil, Poonam; Butovich, Igor A.; Palaniappan, Chendur K.

    2009-01-01

    Purpose Tear lipocalin (Tlc) is a major lipid binding protein in tears and is thought to have an important role in stabilizing the Meibomian lipid layer by transferring lipids to it from the aqueous layer or ocular surface, or by adsorbing to it directly. These possible roles have been investigated in vitro using human Tlc. Methods Tlc was purified from human tears by size exclusion chromatography followed by ion exchange chromatography. Three additional samples of the Tlc were prepared by lipidation, delipidation, and relipidation. The lipids extracted from the purified Tlc were analyzed by HPLC-MS followed by fragmentation. Adsorption of these different forms of Tlc to a human Meibomian lipid film spread on the surface of an artificial tear buffer in a Langmuir trough were observed by recording changes in the pressure with time (∏-T profile) and monitoring the appearance of the film microscopically. These results were compared with similar experiments using a bovine Meibomian lipid film. Results The results indicated that Tlc binds slowly to a human Meibomian lipid film compared with lysozyme or lactoferrin, even at 37°C. The adsorption of Tlc to a human Meibomian lipid film was very different from its adsorption to a bovine Meibomian lipid film, indicating the nature of the lipids in the film is critical to the adsorption process. Similarly, the different forms of Tlc had quite distinct adsorption patterns, as indicated both by changes in ∏-T profiles and the microscopic appearance of the films. Conclusions It was concluded that human Tlc was capable of adsorbing to and penetrating into a Meibomian lipid layer, but this process is very complex and depends on both the types of lipids bound to Tlc and the lipid complement comprising the Meibomian lipid film. PMID:18757516

  5. Toroidal coupling and frequency spectrum of tearing modes

    International Nuclear Information System (INIS)

    Edery, D.; Samain, A.

    1989-05-01

    The frequency spectrum of tearing modes is analyzed with the help of a mode coupling model including toroidal effects in the MHD regions and various non linear effects in the resonant layers. In particular it is shown that the sudden damping of the mode rotation and the simultaneous enhancement of the growth rate observed in tokamak, could be explained as a bifurcating solution of the dispersion equation

  6. Stability of multihelical tearing modes in shaped tokamaks

    International Nuclear Information System (INIS)

    Kerner, W.; Tasso, H.

    1982-03-01

    The stability of multihelical tearing modes in tokamaks with shaped cross-sections is determined numerically. The method allows inclusion of a large number of singular surfaces resolved with high accuracy. Poloidal and radial couplings are discussed and the convergence is well understood. High poloidal m number modes are found to be unstable for typical equilibria. Completely stable current distributions have been constructed for D-shaped plasmas. (orig.)

  7. [Neuronal and hormonal regulatory mechanisms of tears production and secretion].

    Science.gov (United States)

    Mrugacz, Małgorzata; Zywalewska, Nella; Bakunowicz-Lazarczyk, Alina

    2005-01-01

    The ocular surface, tear film, lacrimal glands act as a functional unit to preserve the quality of the refractive surface of the eye, and to resist injury and protect the eye against bodily and environmental conditions. Homeostasis of this functional unit involves neuronal and hormonal regulatory mechanisms. The eye appears to be a target organ for sex hormones particulary the androgen, as they modulate the immune system and trophic functions of the lacrimal and Meibomian glands.

  8. [Characteristics of exosomes andmicroparticles discovered in human tears].

    Science.gov (United States)

    Grigor'eva, A E; Tamkovich, S N; Eremina, A V; Tupikin, A E; Kabilov, M R; Chernykh, V V; Vlassov, V V; Laktionov, P P; Ryabchikova, E I

    2016-01-01

    Exosomes represent a sort of extracellular vesicles, which transfer molecular signals in organism and possess markers of producing cells. Our study was aimed at search of exosomes in the tears of healthy humans, confirmation of their nature and examination of exosome morphological and molecular-biological characteristics. The tears (110-340 ml) were collected from 24 healthy donors (aged 46-60 years); individual probes were centrifuged at 20000 g for 15 min to pellet cell debris. The supernatants were examined in electron microscope using negative staining; and they were also used for isolation and purification of the exosomes by filtration (100 nm pore-size) and double ultracentrifugation (90 min at 100000 g, 4°C). The "pellets" were subjected to electron microscopy, immunolabeling. The RNA and DNA were isolated from the samples, and their sizes were evaluated by capillary electrophoresis, the concentration and localization of nucleic acids were determined. Sequencing of DNA was performed using MiSeq ("Illumina", USA), data were analyzed using CLC GW 7.5 ("Qiagen", USA). Sequences were mapped on human genome (hg19). Electron microscopy revealed in supernatants of the tears cell debris, spherical microparticles (20-40 nm), membrane vesicles and macromolecular aggregates. The "pellets" obtained after ultracentrifugation, contained microparticles (17%), spherical and cup-shaped EVs (40-100 nm, 83%), which were positive for CD63, CD9 and CD24 receptors (specific markers of exosomes). Our study showed presence of high amount of exosomes in human tears, and relation of the exosomes with RNA (size less than 200 nt) and DNA (size was 3-9 kb). Sequencing of the DNA showed that about 92% of the reads mapped to human genome.

  9. Diadenosine polyphosphates in the tears of aniridia patients.

    Science.gov (United States)

    Peral, Assumpta; Carracedo, Gonzalo; Pintor, Jesús

    2015-08-01

    To quantify diadenosine polyphosphate levels in tears of congenital aniridia patients to estimate the ocular surface changes associated with congenital aniridia compared to normal individuals. Fifteen patients diagnosed with congenital aniridia and a control group of forty volunteers were studied. Tears were collected to quantify the levels of diadenosine polyphosphates Ap4 A and Ap5 A by high-performance liquid chromatography (H.P.L.C). Break-up time (BUT), corneal staining, McMonnies questionnaire and the Schirmer I test were applied to both groups. Dinucleotides in congenital aniridia patients were higher than in control subjects. For the congenital aniridia group, under 15 years old, the values were 0.77 ± 0.01 μm and 0.17 ± 0.02 μm for Ap4 A and Ap5 A, respectively. The group aged from 15 to 40 years old provided concentrations of 4.37 ± 0.97 μm and 0.46 ± 0.05 μm for Ap4 A and Ap5 A, the group over 40 gave concentrations of 11.17 ± 5.53 μm and 0.68 ± 0.17 μm for Ap4 A and Ap5 A. Dinucleotide concentrations increased with age, being statistically significant different among the three age groups (p tear secretion and no dry eye McMonnies scores, except for the group over 40 years old. BUT values decreased and corneal staining increased with age and correlated with the levels of diadenosine polyphosphates (p tears increase in aniridia patients compared with healthy subjects, and they seem to be related with the progression of corneal disorders in aniridia patients, both of which increase with ageing. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  10. A novel turbulence trigger for neoclassical tearing modes in tokamaks

    International Nuclear Information System (INIS)

    Itoh, Sanae-I.; Yagi, Masatoshi; Itoh, Kimitaka

    2003-07-01

    Stochastic trigger by microturbulence for neoclassical tearing mode (NTM) is studied. NTM induces topological change of magnetic structure and has subcritical nature. Transition rate of probability density function for and statistically-averaged amplitude of NTM are obtained. Boundary in the phase diagram is determined as the statistical long time average of the transition conditions. NTM can be excited by crossing this boundary even in the absence of other global instabilities. (author)

  11. The tearing mode in the long wavelenght limit

    International Nuclear Information System (INIS)

    Paris, R.B.

    1981-06-01

    The value of the logarithmic derivative Δ' in the boundary layer for the plane symmetric resistive tearing mode is calculted analytically for arbitrary wavelength parameter α approximately<1. Its value is given. The familiar 'constant-psi' approximation corresponding to lambda approximately 0 is discussed. The analytic forms in the boundary layer of the normalized magnetic field and velocity perturbations psi and U are obtained

  12. 3-D nonlinear calculations of resistive tearing modes

    International Nuclear Information System (INIS)

    Hicks, H.R.; Holmes, J.A.; Lee, D.K.; Carreras, B.; Waddell, B.V.

    1981-03-01

    Recent numerical calculations of the evolution of resistive tearing modes have been central to the understanding of magnetohydrodynamic activity and disruptions in tokamaks. The nonlinear, 3-D, initial-value computer code RSF has provided many of these results. This code assumes cylindrical geometry with a Fourier series representation in the two periodic coordinates and a finite-difference representation in the radial direction. This choice makes RSF considerably more accurate and efficient than previous codes

  13. Retinal tear presenting in a patient with ectrodactyly ectodermal dysplasia.

    Science.gov (United States)

    Grogg, Jane Ann; Port, Nicholas; Graham, Trevor

    2014-04-01

    This article aims to report a case of known ectrodactyly ectodermal dysplasia in a young male patient who subsequently was found to have a retinal tear and localized retinal detachment. This is a case report of a 22-year-old white male patient with a history of ectrodactyly ectodermal dysplasia. Our patient initially presented with an acute exacerbation of bilateral, red, irritated eyes. No recent changes in vision were reported. The patient's ocular surface disease was consistent with ectrodermal dysplasia syndrome. However, a dilated fundus examination revealed an asymptomatic retinal tear with a surrounding localized retinal detachment. In this case, the patient presented with longstanding ocular surface disease known to be associated with this patient's inherited ectoderm disorder. In addition, this patient revealed a retinal tear, raising the possibility that patients with inherited congenital ectodermal dysplasia could be at risk for damaged structures originating from the neural ectoderm. In this heterogeneous disease, we are contributing to the existing literature a case of ectodermal dysplasia syndrome with obvious ectodermal complications that also had retinal findings leading us to speculate question if neural ectoderm could also be involved in this inherited disease.

  14. Short Term Results of Arthroscopic Repair of Subscapularis Tendon Tear

    Directory of Open Access Journals (Sweden)

    Zohreh Zafarani

    2009-11-01

    Full Text Available Background:Despite being the largest rotator cuff tendon of the shoulder,the function and clinical relevance of subscapularis pathology has been largely ignored in the literature.Although many studies have focused on subscapularis tears recently,majority of them reported techniques for open repair. The advent of arthroscopy and   arthroscopic repair techniques has opened new frontiers in the diagnosis and repair of torn rotator cuff tendons, including the subscapularis.In this article,we review shortterm results of arthroscopic subscapularis repair. Method: Ten patients with subscapularis tendon tear of the rotator cuff were studied   prospectively including 8 men and 2 women with an average age of 49.7±12.8 years and an average delay in treatment of 23.3 months. Clinical outcomes, including the UCLAscore were assessed in all patients after 3 months of the surgery. Results: 6 patients were followed regularly for more than 6 months,while other 4 patients had a follow-up period of more than a year. The pain score improved from 1.75 to 9 and the UCLA score from 8.8 to 30.6.Conclusions: rthroscopic repair of subscapularis tendon tear results in significant subjective and objective improvement and high levels of patient satisfaction.  

  15. Stability of coupled tearing and twisting modes in tokamaks

    International Nuclear Information System (INIS)

    Fitzpatrick, R.

    1994-03-01

    A dispersion relation is derived for resistive modes of arbitrary parity in a tokamak plasma. At low mode amplitude, tearing and twisting modes which have nonideal MHD behavior at only one rational surface at a time in the plasma are decoupled via sheared rotation and diamagnetic flows. At higher amplitude, more unstable open-quote compound close-quote modes develop which have nonideal behavior simultaneously at many surfaces. Such modes possess tearing parity layers at some of the nonideal surfaces, and twisting parity layers at others, but mixed parity layers are generally disallowed. At low mode number, open-quote compound close-quote modes are likely to have tearing parity layers at all of the nonideal surfaces in a very low-β plasma, but twisting parity layers become more probable as the plasma β is increased. At high mode number, unstable twisting modes which exceed a critical amplitude drive conventional magnetic island chains on alternate rational surfaces, to form an interlocking structure in which the O-points and X-points of neighboring chains line up

  16. The resistive tearing instability for generalized resistivity models: Applications

    International Nuclear Information System (INIS)

    Birk, G.T.; Otto, A.

    1991-01-01

    The dispersion relation for the resistive tearing mode is investigated with a general form of the resistivity that allows for evaluating the dependence of the mode on the anomalous dissipation caused by the lower-hybrid-drift turbulence and the ion-acoustic turbulence. The coupling of the plasma dynamic and radiative processes due to a temperature-dependent Spitzer resistivity are also discussed. The dispersion relation is solved numerically for two-dimensional equilibrium configurations with applications to the Earth's magnetosphere and the solar corona. In the case of the parameter regimes of the magnetopause and the solar corona, growth rates that result in realistic time scales for the respective dynamic processes as flux transfer events and solar flares were found. Moreover, the influence of a nonvanishing component of the magnetic field normal to the current sheet on the dispersion relation is examined. The normal field component leads to overstable modes and the growth rate of the pure tearing mode is not altered, whereas the radiative tearing mode is damped effectively

  17. Nonlinear tearing modes in the reversed field pinch

    International Nuclear Information System (INIS)

    Miller, G.

    1989-01-01

    Finite-amplitude islands, which are the saturated states of tearing modes in the reversed field pinch, are calculated. These states are bifurcated noncylindrical equilibrium states. With σ(r) (σequivalentj x B/B 2 ) nonuniform across the plasma, as is consistent with experiment, a variety of m = 1 and m = 0 bifurcated equilibria are possible, instead of just the m = 1 helix calculated for uniform σ(r) by Taylor [in Pulsed High Beta Plasmas, edited by D. Evans (Pergamon, Oxford, 1976), p. 59]. Assuming the magnetic field lines in the reversed field pinch are weakly stochastic, the growth time of an unstable tearing mode is on the inertial time scale, as in the Taylor model, in constrast to growth on the resistive time scale predicted from nonlinear tearing mode theory when magnetic surfaces exist. The dependence of the saturated island width on radius of a conducting shell is investigated. Islands in the reversed field pinch often have magnetic wells in the island interior, which may result in improved confinement in the island regions

  18. Prediction of Hot Tearing Using a Dimensionless Niyama Criterion

    Science.gov (United States)

    Monroe, Charles; Beckermann, Christoph

    2014-08-01

    The dimensionless form of the well-known Niyama criterion is extended to include the effect of applied strain. Under applied tensile strain, the pressure drop in the mushy zone is enhanced and pores grow beyond typical shrinkage porosity without deformation. This porosity growth can be expected to align perpendicular to the applied strain and to contribute to hot tearing. A model to capture this coupled effect of solidification shrinkage and applied strain on the mushy zone is derived. The dimensionless Niyama criterion can be used to determine the critical liquid fraction value below which porosity forms. This critical value is a function of alloy properties, solidification conditions, and strain rate. Once a dimensionless Niyama criterion value is obtained from thermal and mechanical simulation results, the corresponding shrinkage and deformation pore volume fractions can be calculated. The novelty of the proposed method lies in using the critical liquid fraction at the critical pressure drop within the mushy zone to determine the onset of hot tearing. The magnitude of pore growth due to shrinkage and deformation is plotted as a function of the dimensionless Niyama criterion for an Al-Cu alloy as an example. Furthermore, a typical hot tear "lambda"-shaped curve showing deformation pore volume as a function of alloy content is produced for two Niyama criterion values.

  19. Isolated Subscapularis Tendon Tear in a Skeletally Immature Soccer Player.

    Science.gov (United States)

    Avanzi, Paolo; Dei Giudici, Luca; Giovarruscio, Roberto; Gigante, Antonio; Zorzi, Claudio

    2018-03-01

    Subscapularis injury in adolescents, usually associated to an avulsion fracture of the lesser humeral tuberosity, accounts for less than 2% of all fractures of the proximal humerus. Isolated tears of the subscapularis tendon without a history of dislocation and associated avulsion fractures are an even rarer occurrence, and treatment is controversial. This article describes a rare case of a 12-year-old suffering from an isolated subscapularis tear and discusses its management. The patient was evaluated at presentation, and at 1 to 2.5 months after he underwent a cuff tear arthroscopic repair with a single "all suture" anchor loaded with two wires, active/passive range of motion (A/PROM), Constant-Murley score, and American Shoulder and Elbow Surgeons (ASES) score were noted. Patient reported an excellent outcome, recovered the whole ROM, was pain free, and returned to the previous level of activity. Isolated avulsion of the subscapularis tendon requires a high index of suspicion for a proper diagnosis as early treatment is required for a good recovery. Arthroscopy reserves more advantages in proper hands, restoring the previous levels of function and activity. An increase in attention for this condition is mandatory in a society where many adolescents are getting more and more active in high levels of sport activities.

  20. Recurrent rotator cuff tear: is ultrasound imaging reliable?

    Science.gov (United States)

    Gilat, Ron; Atoun, Ehud; Cohen, Ornit; Tsvieli, Oren; Rath, Ehud; Lakstein, Dror; Levy, Ofer

    2018-02-02

    The diagnostic workup of the painful shoulder after rotator cuff repair (RCR) can be quite challenging. The aim of this study was to assess the reliability of ultrasonography (US) for the detection of recurrent rotator cuff tears in patients with shoulder pain after RCR. We hypothesized that US for the diagnosis of recurrent rotator cuff tear after RCR would not prove to be reliable when compared with surgical arthroscopic confirmation (gold standard). In this cohort study (diagnosis), we retrospectively analyzed the data of 39 patients with shoulder pain after arthroscopic RCR who had subsequently undergone US, followed by revision arthroscopy. The rotator cuff was evaluated first using US for the presence of retears. Thereafter, revision arthroscopy was performed, and the diagnosis was either established or disproved. The sensitivity and specificity of US were assessed in reference to revision arthroscopy (gold standard). A rotator cuff retear was indicated by US in 21 patients (54%) and by revision arthroscopy in 26 patients (67%). US showed a sensitivity of 80.8% and specificity of 100% in the diagnosis of rotator cuff retears. Omission of partial rotator cuff retears resulted in a spike in sensitivity to 94.7%, with 100% specificity remaining. US imaging is a highly sensitive and specific test for the detection of recurrent rotator cuff tears, as confirmed by revision arthroscopy, in patients with a painful shoulder after primary RCR. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  1. Diagnosis and rehabilitation of gastrocnemius muscle tear: a case report.

    Science.gov (United States)

    Nsitem, Virginia

    2013-12-01

    This case study presents the epidemiology, etiology, diagnostic criteria, and therapeutic interventions for a common clinical condition - gastrocnemius injury. A 44-year old male presented with acute calf pain with a palpable defect, loss of range of motion, and loss of strength after sustaining a soft tissue injury to the lower leg. The differential diagnosis of tear of the medial head of the gastrocnemius was confirmed by physical examination and diagnostic ultrasound imaging. The patient was treated over a 6 week period. Initially, rehabilitation was approached using the PRICE principles for symptomatic relief, followed by stretching, strengthening, proprioception, and conditioning exercises. At 9-month follow-up post injury, there was no residual impairment in the gastrocnemius muscle function. This case demonstrates the importance of epidemiology, clinical assessment, and the use of diagnostic ultrasound and MRI imaging in the diagnosis of a tear of the medial head of the gastrocnemius muscle. With an accurate diagnosis and comprehension of classification of muscle injuries, management of gastrocnemius tears is straightforward.

  2. Nonlinear dynamics of single-helicity neoclassical MHD tearing instabilities

    International Nuclear Information System (INIS)

    Spong, D.A.; Shaing, K.C.; Carreras, B.A.; Callen, J.D.; Garcia, L.

    1988-10-01

    Neoclassical magnetohydrodynamic (MHD) effects can significantly alter the nonlinear evolution of resistive tearing instabilities. This is studied numerically by using a flux-surface-averaged set of evolution equations that includes the lowest-order neoclassical MHD effects. The new terms in the equations are fluctuating bootstrap current, neoclassical modification of the resistivity, and neoclassical damping of the vorticity. Single-helicity tearing modes are studied in a cylindrical model over a range of neoclassical viscosities (μ/sub e//ν/sup e/) and values of the Δ' parameter of tearing mode theory. Increasing the neoclassical viscosity leads to increased growth rate and saturated island width as predicted analytically. The larger island width is caused by the fluctuating bootstrap current contribution in Ohm's law. The Δ' parameter no longer solely determines the island width, and finite-width saturated islands may be obtained even when Δ' is negative. The importance of the bootstrap current (/approximately/∂/rho///partial derivative/psi/) in the nonlinear dynamics leads us to examine the sensitivity of the results with respect to different models for the density evolution. 11 refs., 8 figs

  3. [Effects of acupuncture on lactoferrin content in tears and tear secretion in patients suffering from dry eyes: a randomized controlled trial].

    Science.gov (United States)

    Shi, Jing-lin; Miao, Wan-hong

    2012-09-01

    With the understanding of the immune inflammatory response in the pathogenesis of dry eyes, and the limitations of widely used artificial tears and numerous pharmaceuticals and methods to promote tear secretion, clinicians pay more attention to the therapies that can promote tear secretion actively. Acupuncture treatment for dry eye may meet this requirement. To observe the clinical efficacy of acupuncture treatment on dry eye and the effects on duration, and to examine the mechanisms of acupuncture in treating patients with dye eyes. The study was performed at Department of Ophthalmology, Shuguang Hospital, Shanghai University of Traditional Chinese Medicine from August 2010 to May 2011. Patients with the primary diagnosis of dry eye were enrolled. Sixty-five patients were randomly divided into treatment group and control group, and were given 3 weeks of acupuncture treatment or artificial tear therapy respectively. The enzyme-linked immunosorbent assay was used to detect the lactoferrin content of the tears before and after treatment. In order to evaluate the efficacy of the treatment methods, the Schirmer I test and break-up time were also measured. Compared with before treatment, the lactoferrin content in the tears of patients in the treatment group increased, break-up time was prolonged and the result of the Schirmer I test showed improvement after 3 weeks of treatment. The indexes mentioned above did not change in the control group after treatment. There were no significant differences in tear lactoferrin and Schirmer I test between one week after treatment and after 3-week treatment in the treatment group, but break-up time was significantly shortened. The result of Schirmer I test in the treatment group was significantly higher than that in the control group one week after treatment. Acupuncture can increase tear lactoferrin level, extend tear film break-up time and promote tear secretion in patients with dry eye in a time-limited trial. With the end of

  4. Goldmann tonometry tear film error and partial correction with a shaped applanation surface

    Directory of Open Access Journals (Sweden)

    McCafferty SJ

    2018-01-01

    Full Text Available Sean J McCafferty,1–4 Eniko T Enikov,5 Jim Schwiegerling,2,3 Sean M Ashley1,3 1Intuor Technologies, 2Department of Ophthalmology, University of Arizona College of Medicine, 3University of Arizona College of Optical Science, 4Arizona Eye Consultants, 5Department of Mechanical and Aerospace, University of Arizona College of Engineering, Tucson, AZ, USA Purpose: The aim of the study was to quantify the isolated tear film adhesion error in a Goldmann applanation tonometer (GAT prism and in a correcting applanation tonometry surface (CATS prism.Methods: The separation force of a tonometer prism adhered by a tear film to a simulated cornea was measured to quantify an isolated tear film adhesion force. Acrylic hemispheres (7.8 mm radius used as corneas were lathed over the apical 3.06 mm diameter to simulate full applanation contact with the prism surface for both GAT and CATS prisms. Tear film separation measurements were completed with both an artificial tear and fluorescein solutions as a fluid bridge. The applanation mire thicknesses were measured and correlated with the tear film separation measurements. Human cadaver eyes were used to validate simulated cornea tear film separation measurement differences between the GAT and CATS prisms.Results: The CATS prism tear film adhesion error (2.74±0.21 mmHg was significantly less than the GAT prism (4.57±0.18 mmHg, p<0.001. Tear film adhesion error was independent of applanation mire thickness (R2=0.09, p=0.04. Fluorescein produces more tear film error than artificial tears (+0.51±0.04 mmHg; p<0.001. Cadaver eye validation indicated the CATS prism’s tear film adhesion error (1.40±0.51 mmHg was significantly less than that of the GAT prism (3.30±0.38 mmHg; p=0.002.Conclusion: Measured GAT tear film adhesion error is more than previously predicted. A CATS prism significantly reduced tear film adhesion error by ~41%. Fluorescein solution increases the tear film adhesion compared to

  5. HIGH-RESOLUTION ULTRASONOGRAPHY OF SHOULDER FOR ROTATOR CUFF TEAR: CORRELATION WITH ARTHROSCOPIC FINDINGS

    Directory of Open Access Journals (Sweden)

    Vishnumurthy H. Y

    2016-09-01

    Full Text Available INTRODUCTION Rotator cuff disease is the most common cause of shoulder pain. Ultrasonography being non-invasive, widely available, more cost-effective method and is the first choice in imaging of rotator cuff tears. Arthroscopy of shoulder is considered as the gold standard for diagnosis of rotator cuff tears. Objective of this study was to compare the diagnostic accuracy of high-resolution ultrasonography of shoulder for rotator cuff tears with arthroscopy of shoulder. METHODS Thirty patients clinically suspected to have rotator cuff tear who underwent ultrasonography and arthroscopy of shoulder were included in the study. Duration of study was for two years. All ultrasonography examinations were conducted in ultrasound machine using GE Voluson 730 PRO high frequency (10-12 MHz linear array transducer done by two experienced radiologists. Arthroscopies were done by two experienced shoulder arthroscopic surgeons. RESULTS Age of the patients with rotator cuff tears ranged from 40 to 80 years. 57% were females and 43% were males among the patients who had rotator cuff tears. 71.43% of the rotator cuff tears were found in the dominant arm. 64.28% of patients with rotator cuff tear had given history of fall or trauma to the corresponding shoulder within 6 months prior to presentation. 39.28% of patients who had rotator cuff tears were known diabetics. Supraspinatus tendon was the most commonly affected tendon, followed by infraspinatus and subscapularis tendons. For overall detection of rotator cuff tears, ultrasonography in comparison with the arthroscopy has sensitivity and specificity of 92.85% and 100%. For detection of full thickness rotator cuff tear, its sensitivity and specificity was 94.73% and 100% and for partial thickness rotator cuff tears 76.92% and 100%. Ultrasonography has 100% sensitivity and specificity for detection of supraspinatus full thickness tear. For supraspinatus partial thickness tear, sensitivity and specificity was 88

  6. The Relationship Between Tear Ferning Patterns and Non-invasive Tear Break-up Time in Normal Asian Population.

    Science.gov (United States)

    Sharanjeet-Kaur; Ho, Chien Yee; Mutalib, Haliza Abdul; Ghazali, Ahmad Rohi

    2016-01-01

    To investigate the relationship between tear ferning patterns (TFP) and non-invasive tear break-up time (NIBUT) in normal Asian subjects. One hundred and forty-five adults with no ocular surface disorders were recruited. TFP and NIBUT were determined. Tears were collected using a capillary tube and allowed to air dry at room temperature for 10min. TFP was later observed using a light microscope and classified according to Rolando's classification. Measurement for NIBUT was obtained using a Tearscope with the slit lamp magnification. It was found that there is no significant difference between gender in TFP (Z=-1.77, P>.05) and NIBUT (Z=-1.475, P>.05). There is also no significant difference between Malay, Chinese, Indian, and other races in TFP, (H(3)=4.85, P>.05) and NIBUT (H(3)=2.18, P>.05). However, there is a significant difference between age groups of 20-29, 30-39, 40-49,and 50-60 years old in both TFP (H(3)=28.25, P<.01) and NIBUT (H(3)=36.50, P<.001). Spearman's correlation showed there was a significant relationship between TFP and NIBUT (r=-0.55, P<.001), age and NIBUT (r=-0.50, P<.001), age and TFP (r=0.41, P<.001), McMonnies score and NIBUT (r=-0.40, P<.001), McMonnies score and TFP (r=0.31, P<.001), as well as age and McMonnies score (r=0.52, P<.001). TFP and NIBUT was age dependent but not gender and race dependent. Older subjects had higher grade of TFP and McMonnies questionnaire score but lower NIBUT value. TFP and NIBUT can be used to assess the tear film quality. Copyright © 2015 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  7. The impact of lipid composition on the stability of the tear fluid lipid layer

    DEFF Research Database (Denmark)

    Kulovesi, P.; Telenius, J.; Koivuniemi, A.

    2012-01-01

    The tear fluid protects the corneal epithelium from drying and pathogens and it also provides nutrients to these cells. Tear fluid is composed of an aqueous layer as well as a lipid layer that resides at the air-tear interface. The function of the lipid layer is to lower the surface tension of th......-neutral lipid ratio. The results provide a plausible rationale for the development of dry eye syndrome in blepharitis patients.......The tear fluid protects the corneal epithelium from drying and pathogens and it also provides nutrients to these cells. Tear fluid is composed of an aqueous layer as well as a lipid layer that resides at the air-tear interface. The function of the lipid layer is to lower the surface tension...

  8. Prevalence of skin tears in the extremities among elderly residents at a nursing home in Denmark

    DEFF Research Database (Denmark)

    Skiveren, J; Wahlers, B; Bermark, S

    2017-01-01

    OBJECTIVE: The aim of the study was to determine the prevalence of skin tears in the extremities and explore factors in relation to skin tears in elderly residents at a Danish nursing home. METHOD: The study was designed as a point prevalence survey and conducted at a nursing home with 140...... residents >65 years of age. The residents were assessed for presence, number and location of skin tears. Data were collected using a data collection sheet developed for this study. The survey team consisted of four expert nurses from a university hospital (two dermatology and two wound care nurses). Data...... were collected over a period of 10 hours spread over two days. RESULTS: Of the 128 participating residents six had skin tears, yielding a prevalence of 4.6 %. In total, 10 skin tears were observed in the 6 residents. The frequency of previous skin tears was 19.5 %. This frequency was significantly...

  9. Interaction of lysozyme with a tear film lipid layer model: A molecular dynamics simulation study.

    Science.gov (United States)

    Wizert, Alicja; Iskander, D Robert; Cwiklik, Lukasz

    2017-12-01

    The tear film is a thin multilayered structure covering the cornea. Its outermost layer is a lipid film underneath of which resides on an aqueous layer. This tear film lipid layer (TFLL) is itself a complex structure, formed by both polar and nonpolar lipids. It was recently suggested that due to tear film dynamics, TFLL contains inhomogeneities in the form of polar lipid aggregates. The aqueous phase of tear film contains lachrymal-origin proteins, whereby lysozyme is the most abundant. These proteins can alter TFLL properties, mainly by reducing its surface tension. However, a detailed nature of protein-lipid interactions in tear film is not known. We investigate the interactions of lysozyme with TFLL in molecular details by employing coarse-grained molecular dynamics simulations. We demonstrate that lysozyme, due to lateral restructuring of TFLL, is able to penetrate the tear lipid film embedded in inverse micellar aggregates. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Differences in Risk Factors for Rotator Cuff Tears between Elderly Patients and Young Patients.

    Science.gov (United States)

    Watanabe, Akihisa; Ono, Qana; Nishigami, Tomohiko; Hirooka, Takahiko; Machida, Hirohisa

    2018-02-01

    It has been unclear whether the risk factors for rotator cuff tears are the same at all ages or differ between young and older populations. In this study, we examined the risk factors for rotator cuff tears using classification and regression tree analysis as methods of nonlinear regression analysis. There were 65 patients in the rotator cuff tears group and 45 patients in the intact rotator cuff group. Classification and regression tree analysis was performed to predict rotator cuff tears. The target factor was rotator cuff tears; explanatory variables were age, sex, trauma, and critical shoulder angle≥35°. In the results of classification and regression tree analysis, the tree was divided at age 64. For patients aged≥64, the tree was divided at trauma. For patients agedrotator cuff tears in this study. However, these risk factors showed different trends according to age group, not a linear relationship.

  11. The Influence of Alloy Composition on the Hot Tear Susceptibility of the Al-Zn-Mg-Cu Alloy System

    International Nuclear Information System (INIS)

    Kim, Jee-Hun; Jo, Jae-Sub; Sim, Woo-Jeong; Im, Hang-Joon

    2012-01-01

    Hot tearing was the most significant casting defect when the castability evaluation of the Al- Zn-Mg-Cu alloy system was conducted. It was related to the solidification range of the alloy. Therefore, the hot tear susceptibility of the AA7075 alloy, whose solidification range is the widest, was evaluated. The hot tear susceptibility was evaluated by using a mold for a hot tearing test designed to create the condition for the occurrence of hot tear in 8 steps. According to the tearing location and shape, a hot tear susceptibility index (HTS) score was measured. The solidification range of each alloy and hot tear susceptibility was compared and thereafter the microstructure of a near tear defect was observed. As a result, the HTS of the AA7075 alloy was found to be 67. Also, the HTS in relation to a change in Zn, Mg, Cu composition showed a difference of about 6-11% compared to the AA7075 alloy.

  12. Ultrasonography versus magnetic resonance imaging in detecting and grading common extensor tendon tear in chronic lateral epicondylitis.

    Directory of Open Access Journals (Sweden)

    Artur Bachta

    Full Text Available To investigate the diagnostic performance and reliability of ultrasonography (US in detecting and grading common extensor tendon (CET tear in patients with chronic lateral epicondylitis (LE, using magnetic resonance imaging (MRI as the reference standard.The study comprised fifty-eight chronic LE patients. Each patient underwent US and MRI. CET status was classified as: high-grade tear (≥50% thickness, low-grade tear (<50% thickness, suspected tear (possible but not evident tear, no tear. Additionally, the following dichotomous scale was used: confirmed or unconfirmed CET tear. Relative US parameters (versus MRI for detecting CET tear included: sensitivity, specificity, positive predictive value (PPV, negative predictive value (NPV and accuracy. The agreement between US and MRI findings was measured using the weighted Cohen kappa coefficient (κ.US showed moderate agreement with MRI in detecting and grading CET tear (κ = 0.49. Sensitivity, specificity, and accuracy in CET tear detecting by US were 64.52%, 85.19%, and 72.73%, respectively. PPV and NPV of US were 83.33% and 67.65%, respectively. No patient with unconfirmed CET tear on US had high-grade CET tear on MRI.Ultrasonography is a valuable imaging modality that can be used as a screening tool to exclude high-grade CET tear in chronic LE patients. Once a tear is evident on US, MRI should be considered to assess precisely the extent of tendon injury.

  13. Two-Tunnel Transtibial Repair of Radial Meniscus Tears Produces Comparable Results to Inside-Out Repair of Vertical Meniscus Tears.

    Science.gov (United States)

    Cinque, Mark E; Geeslin, Andrew G; Chahla, Jorge; Dornan, Grant J; LaPrade, Robert F

    2017-08-01

    Radial meniscus tears disrupt the circumferential fibers and thereby compromise meniscus integrity. Historically, radial tears were often treated with meniscectomy because of an incomplete understanding of the biomechanical consequences of these tears, limited information regarding the biomechanical performance of repair, and the technical difficulty associated with repair. There is a paucity of studies on the outcomes of the repair of radial meniscus tears. Purpose/Hypothesis: The purpose was to determine the outcomes of 2-tunnel transtibial repair of radial meniscus tears and compare these results to the outcomes of patients who underwent the repair of vertical meniscus tears with a minimum of 2-year follow-up. The hypothesis was that radial and vertical meniscus tear repair outcomes were comparable. Cohort study; Level of evidence, 3. Patients who underwent 2-tunnel transtibial pullout repair for a radial meniscus tear were included in this study and compared with patients who underwent inside-out repair for a vertical meniscus tear. Subjective questionnaires were administered preoperatively and at a minimum of 2-year follow-up, including the Lysholm score, the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the Short Form-12 (SF-12) physical component summary (PCS), the Tegner activity scale, and patient satisfaction. Analysis of covariance was used to compare postoperative outcome scores between the meniscus repair groups while accounting for baseline scores. Adjusted mean effects relative to the radial repair group were reported with 95% CIs. Twenty-seven patients who underwent 2-tunnel transtibial pullout repair for radial meniscus tears and 33 patients who underwent inside-out repair for vertical meniscus tears were available for follow-up at a mean of 3.5 years (range, 2.0-5.4 years). No preoperative outcome score significantly differed between the groups. There were no significant group differences for any of the 2-year

  14. HIGH-RESOLUTION ULTRASONOGRAPHY OF SHOULDER FOR ROTATOR CUFF TEAR: CORRELATION WITH ARTHROSCOPIC FINDINGS

    OpenAIRE

    Vishnumurthy H. Y; Jagdeesh K. S; Anand K; Ranoji Mane; Sanath G. Kamte; Fathima Zohra; Banerji B. H; Sathish Servegar

    2016-01-01

    INTRODUCTION Rotator cuff disease is the most common cause of shoulder pain. Ultrasonography being non-invasive, widely available, more cost-effective method and is the first choice in imaging of rotator cuff tears. Arthroscopy of shoulder is considered as the gold standard for diagnosis of rotator cuff tears. Objective of this study was to compare the diagnostic accuracy of high-resolution ultrasonography of shoulder for rotator cuff tears with arthroscopy of shoulder. METHODS...

  15. Ahaustral colonic segment following trauma: a possible sign of seromuscular tear

    International Nuclear Information System (INIS)

    Webster, H.L.; Johnson, J.F. III; Torres, C.M.

    2001-01-01

    Although traumatic seromuscular tears of the colon are often managed conservatively, it is pertinent to detect the tear since it poses a risk for acute or delayed perforation. Unfortunately, clinical findings are inadequate for detecting and monitoring this lesion. Therefore, this complication has not been recognized prior to laporatomy. We have noted that an ahaustral colonic segment following trauma may be a potential marker for seromuscular tear. (orig.)

  16. The importance of the precorneal tear film for the quality of optical imaging.

    OpenAIRE

    Rieger, G

    1992-01-01

    The optical function of the eye critically depends on the presence of an intact precorneal tear film. Abnormalities of the tear film such as those occurring in the dry eye syndrome or in otherwise irritated eyes may interfere with vision. In 30 patients with dry eyes artificial tears were found to produce statistically significant improvement of vision (p less than 0.001) while no significant changes were seen in the untreated partner eyes. Static perimetry in another 30 patients using the 'm...

  17. Pectoralis major tears: anatomy, classification, and diagnosis with ultrasound and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Chiavaras, Mary M. [McMaster University, Department of Radiology, Hamilton, ON (Canada); Jacobson, Jon A. [University of Michigan, Department of Radiology, Ann Arbor, MI (United States); Smith, Jay [Department of Physical Medicine and Rehabilitation, Mayo Clinic, Rochester, MN (United States); Department of Radiology, Mayo Clinic, Rochester, MN (United States); Department of Anatomy, Mayo Clinic, Rochester, MN (United States); Dahm, Diane L. [Department of Orthopaedic Surgery, Mayo Clinic, Rochester, MN (United States)

    2014-09-09

    Accurate characterization of pectoralis major tears is important to guide management. Imaging evaluation with ultrasound and MR imaging can be difficult given the complex regional anatomy. In addition, recent literature has redefined the anatomy of the distal pectoralis major. The purpose of this study is to review pectoralis major injuries taking into account new anatomic descriptions using ultrasound and MR imaging, including cadaveric dissection, surgically produced pectoralis tears, and clinical pectoralis tendon tear with surgical correlation. (orig.)

  18. Tears of anterior cruciate ligament and associated injury in the knee joint: MR imaging

    International Nuclear Information System (INIS)

    Kim, Eui Jong; Ryu, Kyung Nam; Ahn, Jin Whan; Yoon, Yup

    1994-01-01

    The objective of the study was to evaluate the characteristic findings in tears of the anterior cruciate ligament(ACL) and associated injury at MR imaging. We reviewed the findings of MR images and the corresponding arthroscopic results of 32 patients with ACL tears. We evaluated the signal intensity and contour of ACL surrounding bony structures, menisci and associated injury of the knee joint. Complete ACL tears were present in 25 patients and partial ACL tears were in 7 patients. Complete ACL tears showed heterogenously increased signal intensity with contour bulging of the ACL in 14 patients (56%) and without bulging or absence in 11 patients(44%). Most patients torn ACL with contour bulging(12/14) had bone bruise, but only one patient torn ACL without bulging contour had bone bruise. ACL with thin continuous low signal band surrounding heterogenously increased signal intensity suggests partial tear which was seen in three patients of seven proved partial ACL tears. Combined bone injury in ACL tear were in 23 patients (73%) and most of these(22/23) were at midportion of lateral notch of femur and/or posterior portion of lateral tibial plateu. Deepening of lateral notch of femur were noted in 17 patients(53%). Associated injuries of the other ligaments of knee joint were buckling of the posterior cruciate ligament(16/32, 50%) and tears of the medial collateral ligament(11/32, 34%). Posterior horns of menisci were more frequent site of combined injury within menisci in patients with ACL tear. Acute tearing of ACL in MRI is seen as heterogenously increased signal intensity with contour bulging of ACL and combined bone bruises. Patients with torn ACL frequently have various combined injury. In patient with knee injury, these associated or ancillary findings suggest that ACL tear is present

  19. A New Criterion for Prediction of Hot Tearing Susceptibility of Cast Alloys

    Science.gov (United States)

    Nasresfahani, Mohamad Reza; Niroumand, Behzad

    2014-08-01

    A new criterion for prediction of hot tearing susceptibility of cast alloys is suggested which takes into account the effects of both important mechanical and metallurgical factors and is believed to be less sensitive to the presence of volume defects such as bifilms and inclusions. The criterion was validated by studying the hot tearing tendency of Al-Cu alloy. In conformity with the experimental results, the new criterion predicted reduction of hot tearing tendency with increasing the copper content.

  20. The Effect Of Weave Construction On Tear Strength Of Woven Fabrics

    Directory of Open Access Journals (Sweden)

    Eryuruk Selin Hanife

    2015-09-01

    Full Text Available The tear strength of a woven fabric is very important, since it is more closely related to serviceability of the fabric. Tearing strength of the fabrics depend on the mobility of the yarn within the fabric structure. In this study, the tearing strength of four types of fabrics warp rib, weft rib, ripstop and plain weave were analysed, which were produced in different densities and with filament and texturised polyester yarns.

  1. Development and modeling of hot tearing test in TIG welding of aluminum alloy 6056

    OpenAIRE

    Niel , Aurélie; Fras , Gilles; Deschaux-Beaume , Frédéric; Bordreuil , Cyril

    2010-01-01

    International audience; TIG welding process is widely used in the aeronautic industry. However, the increase of productivity which generally require an increase of welding speed is limited by the appearance of defects, such as hot tearing. This study focuses on the analysis of hot tearing in TIG welding on a 6056 aluminum alloy, used in aircraft manufacturing. Thanks to the developpement of an original hot tearing test and to numerical simulation of welding process, the influence of various p...

  2. Isolated Traumatic Brachialis Muscle Tear: A Case Report and Review of Literature

    OpenAIRE

    Sharma, Pankaj; Mehta, Nishank; Narayan, Amit

    2017-01-01

    Isolated traumatic brachialis muscle tears are uncommonly reported – leading to occasional misdiagnosis and misdirected treatment. The rarity of brachialis muscle tear may promote misdiagnosis or mistreatment of this injury. We report an isolated brachialis muscle tear in a young female, possibly caused by strenuous exercise in the gymnasium. The diagnosis was made clinically and confirmed by magnetic resonance imaging. The patient was subsequently managed adequately with conservative treatme...

  3. Pectoralis major tears: anatomy, classification, and diagnosis with ultrasound and MR imaging

    International Nuclear Information System (INIS)

    Chiavaras, Mary M.; Jacobson, Jon A.; Smith, Jay; Dahm, Diane L.

    2015-01-01

    Accurate characterization of pectoralis major tears is important to guide management. Imaging evaluation with ultrasound and MR imaging can be difficult given the complex regional anatomy. In addition, recent literature has redefined the anatomy of the distal pectoralis major. The purpose of this study is to review pectoralis major injuries taking into account new anatomic descriptions using ultrasound and MR imaging, including cadaveric dissection, surgically produced pectoralis tears, and clinical pectoralis tendon tear with surgical correlation. (orig.)

  4. MR imaging appearance of 180-360 labral tears of the shoulder

    International Nuclear Information System (INIS)

    Lindauer, Kelly R.; Major, Nancy M.; Rougier-Chapman, Duncan P.; Helms, Clyde A.

    2005-01-01

    Glenoid labral tears exceeding 180 are an uncommon entity in which characteristic clinical and MR imaging features can lead to a more accurate preoperative diagnosis. We provide a description of glenoid labral tears that exceed 180 , and their characteristic magnetic resonance imaging features. In the young, heavily muscled male athlete, the identification of multiple sites of labral pathology and isolated, extensive posterior labral injuries are features that should raise suspicion for labral tears that exceed 180 . (orig.)

  5. Shale gases, a windfall for France?

    International Nuclear Information System (INIS)

    Tonnac, Alain de; Perves, Jean-Pierre

    2013-11-01

    After having recalled the definition and origin of shale gases, the different non conventional gases and their exploitation techniques (hydraulic fracturing and horizontal drilling) this report examines whether these gases are an opportunity for France. Some characteristics and data of the fossil and gas markets are presented and commented: world primary energy consumption, proved reserves of non conventional gases and their locations, European regions which may possess reserves of shale gases and coal-bed methane, origins of gas imports in France. The second part addresses shale gas deposits and their exploitation: discussion of the influence of the various rock parameters, evolution of production. The third part discusses the exploitation techniques and specific drilling tools. The issue of exploitation safety and security is addressed as well as the associated controversies: about the pollution of underground waters, about the fact that deep drillings result in pollution, about the risks associated with hydraulic fracturing and injections of chemical products, about the hold on ground and site degradation, about water consumption, about pollution due to gas pipeline leakage, about seismic risk, about noise drawbacks, about risks for health, about exploration and production authorization and license, and about air pollution and climate. The last part addresses the French situation and its future: status of the energy bill, recommendations made by a previous government, cancellation of authorizations, etc. Other information are provided in appendix about non conventional hydrocarbons, about shale gas exploitation in the USA, and about the Lacq gas

  6. A very rare case of bloody tears with enigmatic epistaxis and haematuria.

    Science.gov (United States)

    Ho, Jason Z S; de Silva, Julian; Olver, Jane

    2011-03-01

    Bloody tears are a rare symptom that can be caused by local or systemic pathology. We describe a very rare case of bloody tears that resulted from hyperthyroidism. A 15-year-old female patient presented with a 6-month history of bloody tears and epistaxis. Examination excluded local ocular and nasal pathology, including neoplasm and coagulopathy. Systemic investigations identified elevated thyroid function and following treatment her symptoms resolved. We discuss the mechanism by which hyperthyroidism may induce haemostatic dysfunction. We present the first case of bloody tears secondary to thyroid dysfunction.

  7. The Impact of Ceramic Shell Strength on Hot Tearing during Investment Casting

    International Nuclear Information System (INIS)

    Norouzi, Saeid; Farhangi, Hassan

    2011-01-01

    The effect of ceramic shell strength on hot tearing susceptibility during solidification was inspected practicing investment casting of the cobalt-base superalloy samples with the same casting conditions, but different ceramic shell systems. Results showed that the lower the ceramic shell strength upon using polymer additives, the lower the hindered contraction rate, and the lower the hindered contraction rate, the smaller the hot tearing tendency. Optical microscopy and electron microscopy scanning revealed that the hot tear propagated along the last solidified interdendritic phase, and that the hot tear surface had two major modes: 1) the ductile region in the outer layer; and 2) the inner region of liquid embrittlement.

  8. Facile Determination of Sodium Ion and Osmolarity in Artificial Tears by Sequential DNAzymes.

    Science.gov (United States)

    Kim, Eun Hye; Lee, Eun-Song; Lee, Dong Yun; Kim, Young-Pil

    2017-12-07

    Despite high relevance of tear osmolarity and eye abnormality, numerous methods for detecting tear osmolarity rely upon expensive osmometers. We report a reliable method for simply determining sodium ion-based osmolarity in artificial tears using sequential DNAzymes. When sodium ion-specific DNAzyme and peroxidase-like DNAzyme were used as a sensing and detecting probe, respectively, the concentration of Na⁺ in artificial tears could be measured by absorbance or fluorescence intensity, which was highly correlated with osmolarity over the diagnostic range ( R ² > 0.98). Our approach is useful for studying eye diseases in relation to osmolarity.

  9. Signs of knee osteoarthritis common in 620 patients undergoing arthroscopic surgery for meniscal tear

    DEFF Research Database (Denmark)

    Pihl, Kenneth; Englund, Martin; Lohmander, L. Stefan

    2017-01-01

    Background and purpose - Recent evidence has questioned the effect of arthroscopic knee surgery for middle-aged and older patients with degenerative meniscal tears with or without concomitant radiographic knee osteoarthritis (OA). We investigated the prevalence of early or more established knee OA...... and patients' characteristics in a cohort of patients undergoing arthroscopic surgery for a meniscal tear. Patients and methods - 641 patients assigned for arthroscopy on suspicion of meniscus tear were consecutively recruited from February 2013 through January 2015. Of these, 620 patients (mean age 49 (18...... established knee OA was present in 43% of patients undergoing knee arthroscopy for meniscal tear....

  10. Ultrasonography of symptomatic rotator cuff tears compared with MR imaging and surgery

    International Nuclear Information System (INIS)

    Fotiadou, Anastasia N.; Vlychou, Marianna; Papadopoulos, Periklis; Karataglis, Dimitrios S.; Palladas, Panagiotis; Fezoulidis, Ioannis V.

    2008-01-01

    Purpose: To compare the accuracy of ultrasonography and magnetic resonance imaging in the detection of rotator cuff tears. Materials and methods: Ninety-six patients with clinically suspected rotator cuff pathology underwent ultrasonography and magnetic resonance imaging of the shoulder. The findings in 88 patients were compared with arthroscopy or open surgery. Results: Full-thickness tear was confirmed in 57 cases, partial-thickness tear in 30 cases and degenerative changes without tear in 1. In all 57 cases of full-thickness tear and in 28 out of 30 cases of partial-thickness tear the supraspinatus tendon was involved. The accuracy in the detection of full-thickness tears was 98 and 100% for ultrasonography and magnetic resonance imaging, respectively. The accuracy in the detection of bursal or articular partial-thickness tears was 87 and 90% for ultrasonography and magnetic resonance imaging, respectively. Conclusions: In experienced hands ultrasonography should be considered as an accurate modality for the initial investigation of rotator cuff, especially supraspinatus, tears

  11. Hyperosmolar Tears Induce Functional and Structural Alterations of Corneal Nerves: Electrophysiological and Anatomical Evidence Toward Neurotoxicity.

    Science.gov (United States)

    Hirata, Harumitsu; Mizerska, Kamila; Marfurt, Carl F; Rosenblatt, Mark I

    2015-12-01

    In an effort to elucidate possible neural mechanisms underlying diminished tearing in dry eye disease, this study sought to determine if hyperosmolar tears, a ubiquitous sign of dry eye disease, produce functional changes in corneal nerve responses to drying of the cornea and if these changes correlate with alterations in corneal nerve morphology. In vivo extracellular electrophysiological recordings were performed in rat trigeminal ganglion neurons that innervated the cornea before, and up to 3 hours after, the ocular application of continuous hyperosmolar tears or artificial tears. In corollary experiments, immunohistochemical staining was performed to compare corneal nerve morphology in control and in eyes treated with hyperosmolar solutions. Our previous studies identified a population of corneal afferents, dry-sensitive neurons that are strongly excited by corneal dessication ("dry response"), a response thought to trigger the lacrimation reflex. In the present study, we found that the dry responses of corneal dry-sensitive neurons were depressed or even completely abolished by hyperosmolar tears in a time- (30 minutes to 3 hours) and dose (450- to 1000-mOsm solutions)-dependent manner. Furthermore, eyes treated with hyperosmolar tears for 3 hours contained large numbers of morphologically abnormal (granular, fragmented, or prominently beaded) subbasal nerves that appeared to be undergoing degeneration. These results demonstrate that tear hyperosmolarity, considered to be a "core" mechanism of dry eye disease, significantly decreases physiological sensitivity and morphologic integrity of the corneal nerves important in tear production. These alterations might contribute to the diminished tearing seen clinically in dry eye patients.

  12. Interferometer for measuring the dynamic surface topography of a human tear film

    Science.gov (United States)

    Primeau, Brian C.; Greivenkamp, John E.

    2012-03-01

    The anterior refracting surface of the eye is the thin tear film that forms on the surface of the cornea. Following a blink, the tear film quickly smoothes and starts to become irregular after 10 seconds. This irregularity can affect comfort and vision quality. An in vivo method of characterizing dynamic tear films has been designed based upon a near-infrared phase-shifting interferometer. This interferometer continuously measures light reflected from the tear film, allowing sub-micron analysis of the dynamic surface topography. Movies showing the tear film behavior can be generated along with quantitative metrics describing changes in the tear film surface. This tear film measurement allows analysis beyond capabilities of typical fluorescein visual inspection or corneal topography and provides better sensitivity and resolution than shearing interferometry methods. The interferometer design is capable of identifying features in the tear film much less than a micron in height with a spatial resolution of about ten microns over a 6 mm diameter. This paper presents the design of the tear film interferometer along with the considerations that must be taken when designing an interferometer for on-eye diagnostics. Discussions include eye movement, design of null optics for a range of ocular geometries, and laser emission limits for on-eye interferometry.

  13. Magnetic resonance imaging appearance of partial latissimus dorsi muscle tendon tear

    International Nuclear Information System (INIS)

    Le, Huy B.Q.; Lee, Steven T.; Lane, Michael D.; Munk, Peter L.; Malfair, David; Blachut, Piotr A.

    2009-01-01

    There is still a paucity of information about the clinical presentation, treatment and imaging findings of latissimus muscle tears. Only one study has specifically described the magnetic resonance imaging (MRI) features of latissimus tendon tears. We describe a case of a high-grade tear in the latissimus muscle tendon in an active water skier with no significant prior medical history. MRI demonstrated at least a 50% tear of the latissimus tendon, manifesting as increased signal intensity on T2-weighted sequences and surrounding edema, as well as a diminutive tendon at the humeral insertion. (orig.)

  14. Isolated Traumatic Brachialis Muscle Tear: A Case Report and Review of Literature.

    Science.gov (United States)

    Sharma, Pankaj; Mehta, Nishank; Narayan, Amit

    2017-10-01

    Isolated traumatic brachialis muscle tears are uncommonly reported - leading to occasional misdiagnosis and misdirected treatment. The rarity of brachialis muscle tear may promote misdiagnosis or mistreatment of this injury. We report an isolated brachialis muscle tear in a young female, possibly caused by strenuous exercise in the gymnasium. The diagnosis was made clinically and confirmed by magnetic resonance imaging. The patient was subsequently managed adequately with conservative treatment. We herein present a 35-year-old woman who was diagnosed with an acute brachialis muscle tear being diagnosed with a combination of clinical signs and imaging and successfully managed non-operatively. A chronologically arranged review of literature is also presented.

  15. Ultrasonography of symptomatic rotator cuff tears compared with MR imaging and surgery

    Energy Technology Data Exchange (ETDEWEB)

    Fotiadou, Anastasia N. [Radiology Department, University Hospital of Larissa, Mezourlo 41110, Larissa (Greece); Radiology Department, G. Papanikolaou Hospital, Exochi 32100, Thessaloniki (Greece)], E-mail: natfot@yahoo.gr; Vlychou, Marianna [Radiology Department, University Hospital of Larissa, Mezourlo 41110, Larissa (Greece)], E-mail: mvlychou@med.uth.gr; Papadopoulos, Periklis [University Orthopaedic Clinic, G. Papanikolaou Hospital, Exochi 32100, Thessaloniki (Greece)], E-mail: perpap@otenet.gr; Karataglis, Dimitrios S. [University Orthopaedic Clinic, G. Papanikolaou Hospital, Exochi 32100, Thessaloniki (Greece)], E-mail: dkarataglis@yahoo.gr; Palladas, Panagiotis [Radiology Department, G. Papanikolaou Hospital, Exochi 32100, Thessaloniki (Greece)], E-mail: palladaspan@in.gr; Fezoulidis, Ioannis V. [Radiology Department, University Hospital of Larissa, Mezourlo 41110, Larissa (Greece)], E-mail: oswestanast@yahoo.gr

    2008-10-15

    Purpose: To compare the accuracy of ultrasonography and magnetic resonance imaging in the detection of rotator cuff tears. Materials and methods: Ninety-six patients with clinically suspected rotator cuff pathology underwent ultrasonography and magnetic resonance imaging of the shoulder. The findings in 88 patients were compared with arthroscopy or open surgery. Results: Full-thickness tear was confirmed in 57 cases, partial-thickness tear in 30 cases and degenerative changes without tear in 1. In all 57 cases of full-thickness tear and in 28 out of 30 cases of partial-thickness tear the supraspinatus tendon was involved. The accuracy in the detection of full-thickness tears was 98 and 100% for ultrasonography and magnetic resonance imaging, respectively. The accuracy in the detection of bursal or articular partial-thickness tears was 87 and 90% for ultrasonography and magnetic resonance imaging, respectively. Conclusions: In experienced hands ultrasonography should be considered as an accurate modality for the initial investigation of rotator cuff, especially supraspinatus, tears.

  16. Radial tear of posterior horn of the medial meniscus and osteonecrosis of the knee

    International Nuclear Information System (INIS)

    Motoyama, Tatsuo; Ihara, Hidetoshi; Kawashima, Mahito

    2003-01-01

    We studied the relation between a radial tear of the posterior horn of the medial meniscus and osteonecrosis of the knee. Thirty-eight knees of 37 patients were diagnosed as medial meniscus tear and received arthroscopic knee surgery. We divided them into two groups: knees having radial tear of the posterior horn of the medial meniscus (posterior horn group) and knees containing radial tear except for posterior horn, horizontal tear, degenerative tear, and flap tear of the medial meniscus (non-posterior horn group). The posterior horn group consisted of 14 knees (average age: 65.1 years old) and the non-posterior horn group consisted of 24 knees (average age: 59.6 years old). All cases underwent MRI before arthroscopy. MRI findings were classified into three types (typical osteonecrosis, small osteonecrosis, and non-osteonecrosis). In the posterior horn group, typical osteonecrosis were five knees and small osteonecrosis were five knees, while in the non-posterior horn group only three knees were small osteonecrosis. These findings suggest the relevance between radial tear of the posterior horn of the medial meniscus and osteonecrosis of the knee (Mann-Whitney test p<0.01). The etiology of spontaneous osteonecrosis of the knee joint is unknown, however one etiology could be the radial tear of the posterior horn of the medial meniscus. (author)

  17. Posterior meniscus root tears: associated pathologies to assist as diagnostic tools.

    Science.gov (United States)

    Matheny, Lauren M; Ockuly, Andrew C; Steadman, J Richard; LaPrade, Robert F

    2015-10-01

    The purpose of this study was to investigate associated pathologies identified at arthroscopy in patients with meniscus root tears. This study was Institutional Review Board approved. All patients who underwent arthroscopic knee surgery where a complete meniscus root tear was identified were included in this study. Concurrent ligament tears and articular cartilage changes ≥Outerbridge grade 2 were recorded and stored in a data registry. Fifty patients (28 males, 22 females) [mean age = 36.5 years (range 17.1-68.1 years)] who were diagnosed with a medial or lateral meniscus root tear at arthroscopy were included in this study out of 673 arthroscopic surgeries (prevalence 7.4 %). Twenty-three (46 %) patients had a medial meniscus root tear, 26 (52 %) patients had a lateral meniscus root tear and one (2 %) patient had both. Thirty-four per cent of patients (n = 17) underwent partial meniscectomy, while 60 % (n = 31) underwent suture repair. During arthroscopy, 60 % (n = 30) of patients were diagnosed with an anterior cruciate ligament (ACL) tear. Patients with lateral meniscus root tears were 10.3 times (95 % CI 2.6-42.5) more likely to have ACL tears than patients with medial meniscus root tears (p = 0.012). Patients who had medial meniscus root tears were 5.8 times (95 % CI 1.6-20.5) more likely to have chondral defects than patients who had lateral meniscus root tears (p = 0.044). In this study, patients' preoperative functional scores and activity levels were low. Patients with lateral meniscal root tears were more likely to have an ACL tear. Patients with medial meniscal root tears were more likely to have an knee articular cartilage defect with an Outerbridge grade 2 or higher chondral defect. This study confirms the importance of comprehensive assessment of concurrent injuries to properly diagnose meniscus root tears. IV.

  18. Tears from children with chronic hepatitis B virus (HBV) infection are infectious vehicles of HBV transmission: experimental transmission of HBV by tears, using mice with chimeric human livers.

    Science.gov (United States)

    Komatsu, Haruki; Inui, Ayano; Sogo, Tsuyoshi; Tateno, Akihiko; Shimokawa, Reiko; Fujisawa, Tomoo

    2012-08-15

    Body fluids such as saliva, urine, sweat, and tears from hepatitis B virus (HBV) carriers are potential sources of HBV transmission. Thirty-nine children and 8 adults who were chronically infected with HBV were enrolled. Real-time polymerase chain reaction was used for the quantification of HBV DNA. HBV DNA was detected in 73.7% of urine samples (14 of 19), 86.8% of saliva samples (33 of 38), 100% of tear samples (11 of 11), and 100% of sweat samples (9 of 9). Mean HBV DNA levels (±SD) in urine, saliva, tears, and sweat were 4.3 ± 1.1 log copies/mL, 5.9 ± 1.2 log copies/mL, 6.2 ± 0.7 log copies/mL, and 5.2 ± 0.6 log copies/mL, respectively. A statistically significant correlation was observed between the HBV DNA level in serum specimens and HBV DNA levels in saliva and tear specimens (r = 0.88; P Tear specimens from a child were injected intravenously into 2 human hepatocyte-transplanted chimeric mice. One week after inoculation, both chimeric mice had serum positive for HBV DNA. The levels of HBV DNA in tear specimens from young children were high. Tears were confirmed to be infectious, using chimeric mice. Strict precautions should be taken against direct contact with body fluids from HBV carriers with high-level viremia.

  19. Advanced Rotator Cuff Tear Score (ARoCuS): a multi-scaled tool for the classification and description of rotator cuff tears.

    Science.gov (United States)

    Walter, S G; Stadler, T; Thomas, T S; Thomas, W

    2018-03-02

    To introduce a (semi-)quantitative surgical score for the classification of rotator cuff tears. A total of 146 consecutive patients underwent rotator cuff repair and were assessed using the previously defined Advanced Rotator Cuff Tear Score (ARoCuS) criteria: muscle tendon, size, tissue quality, pattern as well as mobilization of the tear. The data set was split into a training (125 patients) and a testing set (21 patients). The training data set fitted a nonlinear predictive model of the tear score based on the ARoCuS criteria, while the testing data served as control. Based on the scoring results, rotator cuff tears were assigned to one of four categories (ΔV I-IV) and received a stage-adapted treatment. For statistical analysis, mean values ± standard deviation, interclass correlation coefficients (ICC) and kappa values were calculated. Overall, 32 patients were classified as ΔV I, 68 as ΔV II and 37 as ΔV III. Nine patients showed ΔV IV tears. Patients of all ΔV groups improved significantly their Constant scores (p tears in a standardized and reproducible manner.

  20. Bose-Einstein condensation of atomic gases

    International Nuclear Information System (INIS)

    Anglin, J. R.; Ketterle, W.

    2003-01-01

    The early experiments on Bose-Einstein condensation in dilute atomic gases accomplished three longstanding goals. First, cooling of neutral atoms into their motional state, thus subjecting them to ultimate control, limited only by Heisenberg uncertainty relation. Second, creation of a coherent sample of atoms, in which all occupy the same quantum states, and the realization of atom lasers - devices that output coherent matter waves. And third, creation of gaseous quantum fluid, with properties that are different from the quantum liquids helium-3 and helium-4. The field of Bose-Einstein condensation of atomic gases has continued to progress rapidly, driven by the combination of new experimental techniques and theoretical advances. The family of quantum degenerate gases has grown, and now includes metastable and fermionic atoms. condensates have become an ultralow-temperature laboratory for atom optics, collisional physics and many-body physics, encompassing phonons, superfluidity, quantized vortices, Josephson junctions and quantum phase transitions. (author)

  1. Density Fluctuations in Uniform Quantum Gases

    International Nuclear Information System (INIS)

    Bosse, J.; Pathak, K. N.; Singh, G. S.

    2011-01-01

    Analytical expressions are given for the static structure factor S(k) and the pair correlation function g(r) for uniform ideal Bose-Einstein and Fermi-Dirac gases for all temperatures. In the vicinity of Bose Einstein condensation (BEC) temperature, g(r) becomes long ranged and remains so in the condensed phase. In the dilute gas limit, g(r) of bosons and fermions do not coincide with Maxwell-Boltzmann gas but exhibit bunching and anti-bunching effect respectively. The width of these functions depends on the temperature and is scaled as √(inverse atomic mass). Our numerical results provide the precise quantitative values of suppression/increase (antibunching and bunching) of the density fluctuations at small distances in ideal quantum gases in qualitative agreement with the experimental observation for almost non-trapped dilute gases.

  2. Method of processing radioactive rare gase

    International Nuclear Information System (INIS)

    Tagusagawa, Atsushi; Tuda, Kazuaki.

    1988-01-01

    Purpose: To obtain a safety processing method without using mechanical pumps or pressure-proof containers and, accordingly, with no risk for the leakage of radioactive rare gas. Method: A container filled with zeolige is inserted with a cover being opened into an autoclave. Meanwhile, krypton-containing gases are supplied to an adsorption tower filled with adsorbents, cooled, adsorbed and then heated to desorb adsorbed krypton. The krypton-containing gases are introduced due to the pressure difference to the autoclave thereby causing krypton to adsorb at ambient temperature to zeolite. Then, the inside of the autoclave is heated to desorb krypton and adsorbed moistures from zeolite and the pressure is elevated. After sending the gases under pressure to the adsorption tower, the zeolite-filled container is taken out from the autoclave, tightly closed and then transferred to a predetermined site. (Takahashi, M.)

  3. GREENHOUSE GASES AND MEANS OF PREVENTION

    Directory of Open Access Journals (Sweden)

    Dušica Stojanović

    2013-09-01

    Full Text Available The greenhouse effect can be defined as the consequence of increased heating of the Earth's surface, as well as the lower atmosphere by carbon dioxide, water vapor, and other trace amounts gases. It is well-known that human industrial activities have released large amounts of greenhouse gases in the atmosphere, about 900 billion tons of carbon dioxide, and it is estimated that up to 450 billion are still in the atmosphere. In comparison to greenhouse gases water vapor is one of the greatest contributors to the greenhouse effect on Earth. Many projects, as does the PURGE project, have tendences to build on the already conducted research and to quantify the positive and negative impacts on health and wellbeing of the population with greenhouse gas reduction strategies that are curently being implemented and should be increasingly applied in various sectors and urban areas, having offices in Europe, China and India.

  4. Dark lump excitations in superfluid Fermi gases

    Science.gov (United States)

    Xu, Yan-Xia; Duan, Wen-Shan

    2012-11-01

    We study the linear and nonlinear properties of two-dimensional matter-wave pulses in disk-shaped superfluid Fermi gases. A Kadomtsev—Petviashvili I (KPI) solitary wave has been realized for superfluid Fermi gases in the limited cases of Bardeen—Cooper—Schrieffer (BCS) regime, Bose—Einstein condensate (BEC) regime, and unitarity regime. One-lump solution as well as one-line soliton solutions for the KPI equation are obtained, and two-line soliton solutions with the same amplitude are also studied in the limited cases. The dependence of the lump propagating velocity and the sound speed of two-dimensional superfluid Fermi gases on the interaction parameter are investigated for the limited cases of BEC and unitarity.

  5. Dark lump excitations in superfluid Fermi gases

    International Nuclear Information System (INIS)

    Xu Yan-Xia; Duan Wen-Shan

    2012-01-01

    We study the linear and nonlinear properties of two-dimensional matter-wave pulses in disk-shaped superfluid Fermi gases. A Kadomtsev—Petviashvili I (KPI) solitary wave has been realized for superfluid Fermi gases in the limited cases of Bardeen—Cooper—Schrieffer (BCS) regime, Bose—Einstein condensate (BEC) regime, and unitarity regime. One-lump solution as well as one-line soliton solutions for the KPI equation are obtained, and two-line soliton solutions with the same amplitude are also studied in the limited cases. The dependence of the lump propagating velocity and the sound speed of two-dimensional superfluid Fermi gases on the interaction parameter are investigated for the limited cases of BEC and unitarity

  6. Gases and vacua handbook of vacuum physics

    CERN Document Server

    Beck, A H

    2013-01-01

    Handbook of Vacuum Physics, Volume 1: Gases and Vacua presents three major topics, which are the fourth to sixth parts of this volume. These topics are the remarks on units of physical quantities; kinetic theory of gases and gaseous flow; and theory of vacuum diffusion pumps. The first topic aims to present concisely the significance of units of physical quantities, catering the need and interest of those who take measurements and make calculations in different fields of vacuum sciences. The technique and applications of this particular topic are also provided. The second main topic focuses sp

  7. Measuring Viscosities of Gases at Atmospheric Pressure

    Science.gov (United States)

    Singh, Jag J.; Mall, Gerald H.; Hoshang, Chegini

    1987-01-01

    Variant of general capillary method for measuring viscosities of unknown gases based on use of thermal mass-flowmeter section for direct measurement of pressure drops. In technique, flowmeter serves dual role, providing data for determining volume flow rates and serving as well-characterized capillary-tube section for measurement of differential pressures across it. New method simple, sensitive, and adaptable for absolute or relative viscosity measurements of low-pressure gases. Suited for very complex hydrocarbon mixtures where limitations of classical theory and compositional errors make theoretical calculations less reliable.

  8. Origins of geothermal gases at Yellowstone

    Science.gov (United States)

    Lowenstern, Jacob B.; Bergfeld, Deborah; Evans, William C.; Hunt, Andrew G.

    2015-01-01

    Gas emissions at the Yellowstone Plateau Volcanic Field (YPVF) reflect open-system mixing of gas species originating from diverse rock types, magmas, and crustal fluids, all combined in varying proportions at different thermal areas. Gases are not necessarily in chemical equilibrium with the waters through which they vent, especially in acid sulfate terrain where bubbles stream through stagnant acid water. Gases in adjacent thermal areas often can be differentiated by isotopic and gas ratios, and cannot be tied to one another solely by shallow processes such as boiling-induced fractionation of a parent liquid. Instead, they inherit unique gas ratios (e.g., CH4/He) from the dominant rock reservoirs where they originate, some of which underlie the Quaternary volcanic rocks. Steam/gas ratios (essentially H2O/CO2) of Yellowstone fumaroles correlate with Ar/He and N2/CO2, strongly suggesting that H2O/CO2 is controlled by addition of steam boiled from water rich in atmospheric gases. Moreover, H2O/CO2 varies systematically with geographic location, such that boiling is more enhanced in some areas than others. The δ13C and 3He/CO2 of gases reflect a dominant mantle origin for CO2 in Yellowstone gas. The mantle signature is most evident at Mud Volcano, which hosts gases with the lowest H2O/CO2, lowest CH4 concentrations and highest He isotope ratios (~16Ra), consistent with either a young subsurface intrusion or less input of crustal and meteoric gas than any other location at Yellowstone. Across the YPVF, He isotope ratios (3He/4He) inversely vary with He concentrations, and reflect varied amounts of long- stored, radiogenic He added to the magmatic endmember within the crust. Similarly, addition of CH4 from organic-rich sediments is common in the eastern thermal areas at Yellowstone. Overall, Yellowstone gases reflect addition of deep, high-temperature magmatic gas (CO2-rich), lower-temperatures crustal gases (4He- and CH4-bearing), and those gases (N2, Ne, Ar) added

  9. Itinerant Ferromagnetism in Ultracold Fermi Gases

    DEFF Research Database (Denmark)

    Heiselberg, Henning

    2012-01-01

    Itinerant ferromagnetism in cold Fermi gases with repulsive interactions is studied applying the Jastrow-Slater approximation generalized to finite polarization and temperature. For two components at zero temperature a second order transition is found at akF ≃ 0.90 compatible with QMC. Thermodyna......Itinerant ferromagnetism in cold Fermi gases with repulsive interactions is studied applying the Jastrow-Slater approximation generalized to finite polarization and temperature. For two components at zero temperature a second order transition is found at akF ≃ 0.90 compatible with QMC...

  10. Flammability characteristics of combustible gases and vapors

    Energy Technology Data Exchange (ETDEWEB)

    Zabetakis, M. G. [Bureau of Mines, Pittsburgh, PA (United States)

    1964-05-01

    This is a summary of the available limit of flammability, autoignition and burning-rate data for more than 200 combustible gases and vapors in air and other oxidants, as well as of empirical rules and graphs that can be used to predict similar data for thousands of other combustibles under a variety of environmental conditions. Spec$c data are presented on the paraffinic, unsaturated, aromatic, and alicyclic hydrocarbons, alcohols, ethers, aldehydes, ketones, and sulfur compounds, and an assortment of fuels, fuel blends, hydraulic fluids, engine oils, and miscellaneous combustible gases and vapors.

  11. Investigations into electrical discharges in gases

    CERN Document Server

    Klyarfel'D, B N

    2013-01-01

    Investigations into Electrical Discharges in Gases is a compilation of scientific articles that covers the advances in the investigation of the fundamental processes occurring in electrical discharges in gases and vapors. The book details the different aspects of the whole life cycle of an arc, which include the initiation of a discharge, its transition into an arc, the lateral spread of the arc column, and the recovery of electric strength after extinction of an arc. The text also discusses the methods for the dynamic measurement of vapor density in the vicinity of electrical discharges, alon

  12. Nanoclusters and Microparticles in Gases and Vapors

    CERN Document Server

    Smirnov, Boris M

    2012-01-01

    Research of processes involving Nanoclusters and Microparticleshas been developing fastin many fields of rescent research, in particular in materials science. To stay at the cutting edge of this development, a sound understanding of the processes is needed. In this work, several processes involving small particles are described, such as transport processes in gases, charging of small particles in gases, chemical processes, atom attachment and quenching of excited atomic particles on surfaces, nucleation, coagulation, coalescence and growth processes for particles and aggregates. This work pres

  13. Indoor air pollution caused by geothermal gases

    International Nuclear Information System (INIS)

    Durand, Michael

    2006-01-01

    This paper discusses the little-known but potentially serious indoor air quality problems that may occur where buildings are constructed on geothermal ground. The main problems are related to seepage of carbon dioxide, hydrogen sulphide, radon and other gases from soil cavities directly into indoor air through perforations in the structure. These gases present a health hazard, and hydrogen sulphide, which is particularly corrosive, may cause problems electrical and electronic systems. Counter-measures are not always effective, so developments in such areas should only be undertaken with a clear understanding of site-specific issues and their possible solutions. (author)

  14. Ultracold Dipolar Gases in Optical Lattices

    OpenAIRE

    Trefzger, C.; Menotti, C.; Capogrosso-Sansone, B.; Lewenstein, M.

    2011-01-01

    This tutorial is a theoretical work, in which we study the physics of ultra-cold dipolar bosonic gases in optical lattices. Such gases consist of bosonic atoms or molecules that interact via dipolar forces, and that are cooled below the quantum degeneracy temperature, typically in the nK range. When such a degenerate quantum gas is loaded into an optical lattice produced by standing waves of laser light, new kinds of physical phenomena occur. These systems realize then extended Hubbard-type m...

  15. Structural Characteristics Are Not Associated With Pain and Function in Rotator Cuff Tears: The ROW Cohort Study.

    Science.gov (United States)

    Curry, Emily J; Matzkin, Elizabeth E; Dong, Yan; Higgins, Laurence D; Katz, Jeffrey N; Jain, Nitin B

    2015-05-01

    Structural characteristics of rotator cuff tears are used in surgical decision making. However, data on the association of tear size with patient-reported pain and function are sparse. To assess the association of tear size, fatty infiltration, and muscle atrophy with shoulder pain/function in patients with cuff tears undergoing operative and nonoperative treatment. Cross-sectional study; Level of evidence, 3. A total of 67 patients with rotator cuff tears were recruited for this longitudinal cohort study. Patients were determined to have a cuff tear using clinical assessment and blinded magnetic resonance imaging review. The Shoulder Pain and Disability Index (SPADI) was used as a measure of shoulder pain and function. Tear size and thickness were not significantly associated with pain (SPADI pain score, 60.6 [95% CI, 49.8-71.5] for partial-thickness tear; 56.8 [95% CI, 42.8-70.7] for tear; 60.4 [95% CI, 51.7-69.0] for ≥2 cm full-thickness tear). Tear size and thickness were not associated with function (SPADI disability score, 42.7 [95% CI, 29.8-55.6] for partial-thickness tear; 37.6 [95% CI, 23.9-51.4] for tear; 45.1 [95% CI, 35.4-54.8] for ≥2 cm full-thickness tear). Fatty infiltration, muscle atrophy, and tendon retraction were also not significantly associated with SPADI pain and disability scores. A Mental Health Index score of tears undergoing operative and nonoperative treatment, pain and functional status were not associated with tear size and thickness, fatty infiltration, and muscle atrophy. Conversely, factors unrelated to cuff anatomy such as mental health, comorbidities, age, and sex were associated with pain/function. These findings have clinical implications during surgical decision making and suggest that pain and functional disability in patients with rotator cuff tears is multifactorial and should not solely be attributed to structural characteristics.

  16. Tear film and ocular surface assessment in psoriasis.

    Science.gov (United States)

    Aragona, Emanuela; Rania, Laura; Postorino, Elisa Imelde; Interdonato, Alberto; Giuffrida, Roberta; Cannavò, Serafinella Patrizia; Puzzolo, Domenico; Aragona, Pasquale

    2018-03-01

    Psoriasis is a skin disease with also systemic involvement: its impact on the eye is not well established and often clinically underestimated. Aim of this study was to investigate the presence of ocular discomfort symptoms and of ocular surface changes in a population of patients with psoriasis. For this cross-sectional, comparative study, 66 patients with psoriasis were subdivided according to the presence of arthritis and to the use of biological therapy. All patients underwent clinical evaluation with the following tests: Ocular Surface Disease Index Questionnaire, Tearscope examination, meibometry, tear film breakup time, corneal and conjunctival fluorescein staining, Schirmer I test, corneal aesthesiometry, meibomian gland dysfunction (MGD) assessment and conjunctival impression cytology. 28 healthy subjects were also enrolled and treated with the same clinical tests. A statistical analysis of the results was performed. Patients with psoriasis showed a significant deterioration of the ocular surface tests, if compared with healthy subjects, demonstrated by tear film lipid layer alteration, tear film instability, corneal and conjunctival epithelial suffering and mild squamous metaplasia at impression cytology. No differences were found in ocular surface test results of the psoriatic group when patients were divided according to the presence of arthritis, whereas the anti-inflammatory treatment with biological drugs demonstrated a significant improvement of corneal stain and MGD. Our findings suggest that the ocular surface involvement in patients with psoriasis indicates the need of periodic ophthalmological examinations to diagnose the condition and allow a proper treatment, so contributing to the amelioration of patients' quality of life. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. MRI in diagnosing partial thickness tears of the rotator cuff

    International Nuclear Information System (INIS)

    Ogawa, Takeshi

    2000-01-01

    In this study 270 patients who had been treated for 10 years and had suspected rupture of the tendon and complete or partial thickness tears of the rotator cuff were diagnosed. Among these patients, MRI images in 50 cases were investigated to establish the diagnostic criteria for partial thickness tears of the rotator cuff. The rupture sites included the bursal surface in 15 shoulders, the articular surface in 30 shoulders, complicated cases of both surfaces in five shoulders with no intrasubstance. As for the imaging method, T2-weighted images were employed and the oblique coronary section, which is parallel to the scapula, was used as a imaging plane. From the results of the variation of the MRI signal intensity in the tendon, it was found that the signal intensity increased to 80% in the rupture of the bursal surface and 93.3% in the rupture of the articular surface. As for sites where the signals in the tendon increased, these were found at the bursal side in 83.3% of rupture at the bursal surface, and at the articular side in 100% of rupture at the articular surface. From these findings, the MRI-diagnostic criteria of partial thickness tears of the rotator cuff was defined as those cases which show a localized increase in signal intensity on the oblique coronary surface of T2 weighted images, but not in whole layers of the tendon. A high diagnostic rate with these criteria could be obtained with a sensitivity of 82.0%, specificity 90.9%, accuracy 84.7%, and positive predictive value 95.3%. (author)

  18. Validating a new device for measuring tear evaporation rates.

    Science.gov (United States)

    Rohit, Athira; Ehrmann, Klaus; Naduvilath, Thomas; Willcox, Mark; Stapleton, Fiona

    2014-01-01

    To calibrate and validate a commercially available dermatology instrument to measure tear evaporation rate of contact lens wearers. A dermatology instrument was modified by attaching a swim goggle cup such that the cup sealed around the eye socket. Results for the unmodified instrument are dependent on probe area and enclosed volume. Calibration curves were established using a model eye, to account for individual variations in chamber volume and exposed area. Fifteen participants were recruited and the study included a contact lens wear and a no contact lens wear stage. Day and diurnal variation of the measurements were assessed by taking the measurement three times a day over 2 days. The coefficient of repeatability of the measurement was calculated and a linear mixed model assessed the influence of humidity, temperature, contact lens wear, day and diurnal variations on tear evaporation rate. The associations between variables were assessed using Pearson correlation coefficient. Absolute evaporation rates with and without contact lens wear were calculated based on the new calibration. The measurements were most repeatable during the evening with no lens wear (COR = 49 g m⁻² h) and least repeatable during the evening with contact lens wear (COR = 93 g m⁻² h). Humidity (p = 0.007), and contact lens wear (p evaporation rate. However, temperature (p = 0.54) diurnal variation (p = 0.85) and different days (p = 0.65) had no significant effect after controlling for humidity. Tear evaporation rates can be measured using a modified dermatology instrument. Measurements were higher and more variable with lens wear consistent with previous literature. Control of environmental conditions is important as a higher humidity results in a reduced evaporation rate. © 2013 The Authors Ophthalmic & Physiological Optics © 2013 The College of Optometrists.

  19. Relationship of Tear Size and Location to Fatty Degeneration of the Rotator Cuff

    Science.gov (United States)

    Kim, H. Mike; Dahiya, Nirvikar; Teefey, Sharlene A.; Keener, Jay D.; Galatz, Leesa M.; Yamaguchi, Ken

    2010-01-01

    Background: Fatty degeneration of the rotator cuff muscles may have detrimental effects on both anatomical and functional outcomes following shoulder surgery. The purpose of this study was to investigate the relationship between tear geometry and muscle fatty degeneration in shoulders with a deficient rotator cuff. Methods: Ultrasonograms of both shoulders of 262 patients were reviewed to assess the type of rotator cuff tear and fatty degeneration in the supraspinatus and infraspinatus muscles. The 251 shoulders with a full-thickness tear underwent further evaluation for tear size and location. The relationship of tear size and location to fatty degeneration of the supraspinatus and infraspinatus muscles was investigated with use of statistical comparisons and regression models. Results: Fatty degeneration was found almost exclusively in shoulders with a full-thickness rotator cuff tear. Of the 251 shoulders with a full-thickness tear, eighty-seven (34.7%) had fatty degeneration in either the supraspinatus or infraspinatus, or both. Eighty-two (32.7%) of the 251 full-thickness tears had a distance of 0 mm between the biceps tendon and anterior margin of the tear. Ninety percent of the full-thickness tears with fatty degeneration in both muscles had a distance of 0 mm posterior from the biceps, whereas only 9% of those without fatty degeneration had a distance of 0 mm. Tears with fatty degeneration had significantly greater width and length than those without fatty degeneration (p Tears with fatty degeneration had a significantly shorter distance posterior from the biceps than those without fatty degeneration (p tear width and length were found to be the most important predictors for infraspinatus fatty degeneration. Conclusions: Fatty degeneration of the rotator cuff muscles is closely associated with tear size and location. The finding of this study suggests that the integrity of the anterior supraspinatus tendon is important to the development of fatty

  20. MRI study of associated shoulder pathology in patients with full-thickness subscapularis tendon tears.

    Science.gov (United States)

    Li, Xinning; Fallon, Jonathan; Egge, Natalie; Curry, Emily J; Patel, Ketan; Owens, Brett D; Busconi, Brian D

    2013-01-01

    Subscapularis tendon tears are a well-established cause of shoulder pain. The objective of the current study was to evaluate the associated shoulder pathology in patients with full-thickness subscapularis tendon tears using magnetic resonance imaging. Forty-seven magnetic resonance imaging studies taken between 2008 and 2009 with a diagnosis of full-thickness subscapularis tendon tears were reviewed. The size of the subscapularis tendon tear, amount of muscle volume loss, Goutallier grade, biceps tendon pathology, coracohumeral distance, and associated rotator cuff tears were recorded. Statistical analysis was performed. Patients 55 years and older vs those 54 years and younger had an average subscapularis tear size of 35 vs 19 mm, an average Goutallier grade of 2.7 vs 0.8, and a total muscle volume loss of 25% vs 5%, respectively. Patients with a dislocated vs normal biceps tendons had an average subscapularis tear size of 37 vs 23 mm, an average Goutallier grade of 3 vs 0.9, and a total muscle volume loss of 28% vs 7%, respectively. Patients with vs without concomitant rotator cuff tears had an average subscapularis tear size of 32 vs 17 mm, an average Goutallier grade of 2.3 vs 0.6, and a total muscle volume loss of 21% vs 3%, respectively. Overall average coracohumeral distance measured in the axial plane was 10.8±4.6 mm. Average coracaohumeral distance was 14.8 vs 8.1 mm in patients with a Goutallier grade of 0 vs 3 or 4, resepectively, and 13.6 vs 8.5 mm in patients with no rotator cuff tear vs those with a supra- and infraspinatus tear, respectively. Increased age, dislocated biceps tendons, and concomitant rotator cuff tears in patients with full-thickness subscapularis tendon tears are associated with larger subscapularis tendon tear size, higher Goutallier grades, and increased subscapularis muscle volume loss. Decreased coracohumeral distance is associated with a higher Goutallier grade and rotator cuff tears. Copyright 2013, SLACK Incorporated.

  1. RETINAL PIGMENT EPITHELIAL TEAR AFTER INTRAVITREAL RANIBIZUMAB TREATMENT FOR NEOVASCULAR AGE-RELATED MACULAR DEGENERATION.

    Science.gov (United States)

    Cho, Han Joo; Kim, Hyoung Seok; Yoo, Seul Gi; Han, Jung Il; Lew, Young Ju; Cho, Sung Won; Lee, Tae Gon; Kim, Jong Woo

    2016-10-01

    To evaluate the risk factors for retinal pigment epithelium (RPE) tears after intravitreal ranibizumab injections in neovascular age-related macular degeneration (nAMD) and to determine the efficacy of continued ranibizumab treatment after RPE tears. A total of 407 treatment-naïve eyes (377 patients) with nAMD were retrospectively included. All patients were treated with an initial series of 3 monthly loading injections, followed by further injections as required. Baseline characteristics and pigment epithelial detachment (PED) lesion features were evaluated as potential risk factors for RPE tear. The visual and anatomical outcomes after treatment during 12 months were also evaluated. By 12 months, RPE tears developed in 32 eyes (7.9%). Pigment epithelial detachment height was associated with a higher risk of RPE tear (odds ratio [OR], 1.318; 95% confidence interval [CI], 1.217-2.031, P = 0.018). Fibrovascular PED compared with serous PED had a higher risk of developing tears (OR, 9.129; 95% CI, 6.228-32.124, P = 0.039), and typical nAMD (OR, 4.166; 95% CI, 2.030-14.913, P = 0.031) and retinal angiomatous proliferation (OR, 3.778; 95% CI, 2.185-9.277, P = 0.040) had a higher risk of developing tears compared with polypoidal choroidal vasculopathy. Mean best-corrected visual acuity (BCVA) of RPE tear patients showed no significant improvement after treatment at 12 months; however, patients with RPE tears without foveal involvement (19 eyes) showed significant BCVA improvement at 12 months (P = 0.034). PED type and nAMD subtype are associated with the development of RPE tears after intravitreal ranibizumab injections. Continued ranibizumab therapy after RPE tear development can maintain visual acuity when the fovea is not involved.

  2. Stabilization of tearing modes to suppress major disruptions in tokamaks

    International Nuclear Information System (INIS)

    Holmes, J.A.; Carreras, B.; Hicks, H.R.; Lynch, S.J.; Waddell, B.V.

    1979-02-01

    It is shown, for q-profiles which lead to a disruption, that the control of the amplitude of the 2/1 tearing mode avoids the disruption. Q-profiles measured in T-4 and PLT before a major disruption were studied. Two methods of controlling the 2/1 mode amplitude have been considered: (1) Feedback stabilization with the feedback signal locked in phase with the 2/1 mode. (2) Heating slightly outside the q = 2 surface. In both cases it is only necessary to decrease the 2/1 mode amplitude to suppress the disruption. It is not always necessary to stabilize the unstable modes fully

  3. Hypodense bubbles in acute extradural haematomas following venous sinus tear

    International Nuclear Information System (INIS)

    Chee, C.P.; Habib, Z.A.

    1991-01-01

    Between January 1982 and December 1989, 12 patients with 13 acute extradural haematomas as a result of injury involving the venous sinuses were treated by the first author. The CT scan apperances in 6 cases were remarkable in that there were large bubbles of low density in the hyperdense haematomas and liquid blood was found during the operation. The possible underlying pathophysiological changes that gave rise this appearance are discussed. The CT scan appearance and the proximity of the clot to the venous sinuses should alert the neurosurgeon to the high probabilities of venous sinus tear such that proper treatment can be offered. (orig.)

  4. Hypodense bubbles in acute extradural haematomas following venous sinus tear

    Energy Technology Data Exchange (ETDEWEB)

    Chee, C.P.; Habib, Z.A. (Malaya Univ. Hospital, Kuala Lumpur (Malaysia). Neurosurgical and Radiological Services)

    1991-04-01

    Between January 1982 and December 1989, 12 patients with 13 acute extradural haematomas as a result of injury involving the venous sinuses were treated by the first author. The CT scan apperances in 6 cases were remarkable in that there were large bubbles of low density in the hyperdense haematomas and liquid blood was found during the operation. The possible underlying pathophysiological changes that gave rise this appearance are discussed. The CT scan appearance and the proximity of the clot to the venous sinuses should alert the neurosurgeon to the high probabilities of venous sinus tear such that proper treatment can be offered. (orig.).

  5. Curvature effect on tearing modes in presence of neoclassical friction

    Energy Technology Data Exchange (ETDEWEB)

    Maget, Patrick; Mellet, Nicolas; Meshcheriakov, Dmytro; Garbet, Xavier [CEA, IRFM, F-13108 Saint Paul-lez-Durance (France); Lütjens, Hinrich [Centre de Physique Théorique, Ecole Polytechnique, CNRS (France)

    2013-11-15

    Neoclassical physics (here associated to the poloidal variation of the magnetic field strength along field lines in a tokamak) is well known for driving self-generated plasma current and nonlinear magnetic islands associated to it in high performance, ITER relevant plasma discharges. It is demonstrated that the neoclassical friction between a magnetic perturbation and plasma flow already impacts magnetic islands in the linear regime, by inducing a weakening of curvature stabilization for tearing modes. This conclusion holds in particular for regimes where convection is influencing the pressure dynamics, as shown using a simple analytical model and confirmed in full Magneto-Hydro-Dynamics simulations.

  6. Effect of ion viscosity on neoclassical tearing mode

    International Nuclear Information System (INIS)

    Yoshida, Shigeki; Itoh, Sanae-I.; Yagi, Masatoshi; Azumi, Masafumi

    2004-01-01

    Linear stability analysis of neoclassical tearing mode (NTM) is performed on the basis of four-field reduced magnetohydrodynamic (MHD) model which takes account of fluctuating ion parallel flow and ion neoclassical viscosity. The dependence of the growth rate on the kinetic effects is investigated. It is shown that the linear NTM is stabilized by ion neoclassical viscosity and that the stabilizing effect of ion parallel compressibility is weak in the banana-plateau regime. It is found that not only ion neoclassical viscosity but also both ion and electron diamagnetic effects are important for the stabilization of NTM. (author)

  7. Tearing-mode stability of a forming Spheromak plasma

    International Nuclear Information System (INIS)

    Heidbrink, W.W.; Jardin, S.C.; Chance, M.S.

    1981-10-01

    The results of numerical calculations of Δ' for a class of equilibria typical of those encountered during the early formation stage of the S1 Spheromak are presented. The equilibrium plasma is assumed to be cylindrically symmetric and pressureless. It encloses a current carrying perfect conductor (flux core) and is surrounded by a vacuum with zero longitudinal field. Stability boundaries in the space formed by the equilibrium parameters are mapped. The plasma is tearing mode stable provided B/sub z//B/sub theta/ at the flux core is below a certain critical value which depends on the equilibrium parameters. For typical equilibria, this critical value is 0.65

  8. Supraspinatus Intramuscular Calcified Hematoma or Necrosis Associated with Tendon Tear

    Directory of Open Access Journals (Sweden)

    Alexandre Lädermann

    2015-01-01

    Full Text Available Introduction. Rotator cuff intramuscular calcification is a rare condition usually caused by heterotopic ossification and myositis ossificans. Case Presentation. We describe a patient with voluminous calcified mass entrapped in supraspinatus muscle associated with corresponding tendon tear. Histological examination corresponded to a calcified hematoma or necrosis. Patient was surgically managed with open excision of the calcified hematoma and rotator cuff arthroscopic repair. At 6 months, supraspinatus muscle was healed, and functional outcome was good. Discussion and Conclusion. We hypothesized that supraspinatus intramuscular calcified hematoma was responsible for mechanical stress on the tendon. This association has never been described.

  9. Shear flows induced by nonlinear evolution of double tearing modes

    International Nuclear Information System (INIS)

    Wang Zhengxiong; Kishimoto, Y.; Li, J. Q.; Wang Xiaogang; Dong, J. Q.

    2008-01-01

    Shear flows induced by nonlinear evolution of double tearing modes are investigated in a resistive magnetohydrodynamic model with slab geometry. It is found that intensive and thin poloidal shear flow layers are generated in the magnetic island region driven by coupled reconnection process at both rational surfaces. The structure of the flow layers keeps evolving after the merging of magnetic separatrices and forms a few narrow vortices along the open field lines in the final stage of magnetic reconnection. The effects of the distance between both rational surfaces and the initial magnetic shear on the nonlinear evolution of the plasma flows are also taken into consideration and the relevant mechanism is discussed

  10. Neoclassical tearing mode stabilization by ECCD in ITER

    International Nuclear Information System (INIS)

    Giruzzi, G.; Zabiego, M.

    2001-01-01

    A dynamic model, based on a 3-D Fokker-Planck code coupled to the island evolution equations, is used to evaluate the feasibility of active control of Neoclassical Tearing modes by Electron Cyclotron Current Drive (ECCD) in International Thermonuclear Experimental Reactor (ITER). The parameters of the present version of ITER, i.e., RTO/RC ITER (IAM option) are used. Both m=3, n=2 and m=2, n=1 modes are considered. It is shown that an Electron Cyclotron wave system at 140 GHz, with toroidally steerable antennas, can stabilize both modes simultaneously if a power ≥30 MW is available

  11. A theorem for non-linear stability to tearing modes

    International Nuclear Information System (INIS)

    Avinash, K.

    1992-12-01

    Within the reduced MHD approximation it is shown that dJ z /dΨ≤0 [J z is z component of the current density and Ψ is the helical flux] is a sufficient condition for the equilibrium to be non-linearly stable to tearing mode. It is further shown that this is also a sufficient condition for an equilibrium to be axisymmetric, hence helical equilibrium consistent with this condition cannot be constructed. However a class of axisymmetric equilibrium with hollow current profile is shown to satisfy the stability criterion. (author). 16 refs, 2 figs

  12. Ultrasonographic features of an adductor longus tear: case report

    Energy Technology Data Exchange (ETDEWEB)

    Goh, Lesley-Ann Hui-huan [Tan Tock Seng Hospital (Singapore); Rethy, C.K.; Wang Shih-chang [National Univ. Hospital (Singapore); Tho Kam San [Alexandra Hospital (Singapore)

    2001-08-01

    Muscle strain of the lower extremities is among the most common injuries in sports. Excessive force, rather than direct trauma, causes disruption of the muscle-tendon unit, usually at the myotendinous junction, and improper rest and rehabilitation of a minor strain can often lead to a far more disabling injury. High-resolution ultrasonography is useful for direct imaging of muscle injuries. We present a case where ultrasonography was used to detect, treat and follow-up an adductor longus tear in a soccer player. (author)

  13. Ultrasonographic features of an adductor longus tear: case report

    International Nuclear Information System (INIS)

    Goh, Lesley-Ann Hui-huan; Rethy, C.K.; Wang Shih-chang; Tho Kam San

    2001-01-01

    Muscle strain of the lower extremities is among the most common injuries in sports. Excessive force, rather than direct trauma, causes disruption of the muscle-tendon unit, usually at the myotendinous junction, and improper rest and rehabilitation of a minor strain can often lead to a far more disabling injury. High-resolution ultrasonography is useful for direct imaging of muscle injuries. We present a case where ultrasonography was used to detect, treat and follow-up an adductor longus tear in a soccer player. (author)

  14. Dynamic modelling of tearing mode stabilization by RF current drive

    International Nuclear Information System (INIS)

    Giruzzi, G.; Zabiego, M.; Gianakon, T.A.; Garbet, X.; Bernabei, S.

    1998-01-01

    The theory of tearing mode stabilization in toroidal plasmas by RF-driven currents that are modulated in phase with the island rotation is investigated. A time scale analysis of the phenomena involved indicates that transient effects, such as finite time response of the driven currents, island rotation during the power pulses, and the inductive response of the plasma, are intrinsically important. A dynamic model of such effects is developed, based on a 3-D Fokker-Planck code coupled to both the electric field diffusion and the island evolution equations. Extensive applications to both Electron Cyclotron and Lower Hybrid current drive in ITER are presented. (author)

  15. Atomic physics effects on tokamak edge drift-tearing modes

    International Nuclear Information System (INIS)

    Hahm, T.S.

    1993-01-01

    The effects of ionization and charge exchange on the linear stability of drift-tearing modes are analytically investigated. In particular, the linear instability threshold Δ Th , produced by ion sound wave coupling [Phys. Rev. Lett. 40, 1500 (1978)] is modified. In the strongly collisional regime, the ionization breaks up the near cancellation of the perturbed electric field and the pressure gradient along the magnetic field, and increases the threshold. In the semicollisional regime, both ionization and charge exchange act as drag on the ion parallel velocity [Phys. Fluids B 4, 2567 (1992)], and consequently decrease the threshold by reducing the effectiveness of ion sound wave propagation

  16. Fate of Gases generated from Nuclear Wastes

    Energy Technology Data Exchange (ETDEWEB)

    Srinivasulu, M.; Francis, A. J. [Pohang Univ. of Science and Technology, Pohang (Korea, Republic of); Francis, A. J. [Brookhaven National Laboratory, New York (United States)

    2013-05-15

    The backfill materials such as cement, bentonite or crushed rock are used as engineered barriers against groundwater infiltration and radionuclide transport. Gas generation from radioactive wastes is attributed to radiolysis, corrosion of metals, and degradation of organic materials. Corrosion of steel drums and biodegradation of organic materials in L/ILW can generate gas which causes pressure build up and has the potential to compromise the integrity of waste containers and release the radionuclides and other contaminants into the environment. Performance assessment therefore requires a detailed understanding of the source and fate of gas generation and transport within the disposal system. Here we review the sources and fate of various type of gases generated from nuclear wastes and repositories. Studies on modeling of the fate and transport of repository gases primarily deal with hydrogen and CO{sub 2}. Although hydrogen and carbon dioxide are the major gases of concern, microbial transformations of these gases in the subterranean environments could be significant. Metabolism of hydrogen along with the carbon dioxide results in the formation of methane, low molecular weight organic compounds and cell biomass and thus could affect the total inventory in a repository environment. Modeling studies should take into consideration of both the gas generation and consumption processes over the long-term.

  17. Electron-Atom Collisions in Gases

    Science.gov (United States)

    Kraftmakher, Yaakov

    2013-01-01

    Electron-atom collisions in gases are an aspect of atomic physics. Three experiments in this field employing a thyratron are described: (i) the Ramsauer-Townsend effect, (ii) the excitation and ionization potentials of xenon and (iii) the ion-electron recombination after interrupting the electric discharge.

  18. Acid dew point measurement in flue gases

    Energy Technology Data Exchange (ETDEWEB)

    Struschka, M.; Baumbach, G.

    1986-06-01

    The operation of modern boiler plants requires the continuous measurement of the acid dew point in flue gases. An existing measuring instrument was modified in such a way that it can determine acid dew points reliably, reproduceably and continuously. The authors present the mechanisms of the dew point formation, the dew point measuring principle, the modification and the operational results.

  19. Properties and Bibliography of GaSe

    Science.gov (United States)

    1994-02-01

    Musaev, A. E. Bakhyshev, N. M. Gasanly and L. G. Musaeva . (1975). "Anisotropy of the optical constants of GaS and GaSe near the absorption edge." Sov...Phys. Semiconductors. 9 94-95 Russian ref.: Fiz. Tekh. Poluprovodn. 9 142-145 (January 1975). Akhundov, G. A., L. G. Musaeva and M. D. Khomutova

  20. Mitigation of greenhouse gases from agriculture

    DEFF Research Database (Denmark)

    Schils, R.L.M.; Ellis, J. L.; de Klein, C. A. M.

    2013-01-01

    Models are widely used to simulate the emission of greenhouse gases (GHG). They help to identify knowledge gaps, estimate total emissions for inventories, develop mitigation options and policies, raise awareness and encourage adoption. These models vary in scale, scope and methodological approach...