WorldWideScience

Sample records for target diagnostic operations

  1. Radiation effects in IFMIF Li target diagnostic systems

    International Nuclear Information System (INIS)

    Molla, J.; Vila, R.; Shikama, T.; Horiike, H.; Simakov, S.; Ciotti, M.; Ibarra, A.

    2009-01-01

    Diagnostics for the lithium target will be crucial for the operation of IFMIF. Several parameters as the lithium temperature, target thickness or wave pattern must be monitored during operation. Radiation effects may produce malfunctioning in any of these diagnostics due to the exposure to high radiation fields. The main diagnostic systems proposed for the operation of IFMIF are reviewed in this paper from the point of view of radiation damage. The main tools for the assessment of the performance of these diagnostics are the neutronics calculations by using specialised codes and the information accumulated during the last decades on the radiation effects in functional materials, components and diagnostics for ITER. This analysis allows to conclude that the design of some of the diagnostic systems must be revised to assure the high availability required for the target system.

  2. Target diagnostic system for the National Ignition Facility (NIF)

    International Nuclear Information System (INIS)

    Leeper, R.J.; Chandler, G.A.; Cooper, G.W.; Derzon, M.S.

    1996-01-01

    A review of recent progress on the design of a diagnostic system proposed for ignition target experiments on the National Ignition Facility (NIF) will be presented. This diagnostic package contains an extensive suite of optical, x-ray, gamma-ray, and neutron diagnostics that enable measurements of the performance of both direct and indirect driven NIF targets. The philosophy used in designing all of the diagnostics in the set has emphasized redundant and independent measurement of fundamental physical quantities relevant to the operation of the NIF target. A unique feature of these diagnostics is that they are being designed to be capable of operating, in the high radiation, EMP, and debris backgrounds expected on the NIF facility. The diagnostic system proposed can be categorized into three broad areas: laser characterization, hohlraum characterization, and capsule performance diagnostics. The operating principles of a representative instrument from each class of diagnostic employed in this package will be summarized and illustrated with data obtained in recent prototype diagnostic tests

  3. ORION laser target diagnostics

    International Nuclear Information System (INIS)

    Bentley, C. D.; Edwards, R. D.; Andrew, J. E.; James, S. F.; Gardner, M. D.; Comley, A. J.; Vaughan, K.; Horsfield, C. J.; Rubery, M. S.; Rothman, S. D.; Daykin, S.; Masoero, S. J.; Palmer, J. B.; Meadowcroft, A. L.; Williams, B. M.; Gumbrell, E. T.; Fyrth, J. D.; Brown, C. R. D.; Hill, M. P.; Oades, K.

    2012-01-01

    The ORION laser facility is one of the UK's premier laser facilities which became operational at AWE in 2010. Its primary mission is one of stockpile stewardship, ORION will extend the UK's experimental plasma physics capability to the high temperature, high density regime relevant to Atomic Weapons Establishment's (AWE) program. The ORION laser combines ten laser beams operating in the ns regime with two sub ps short pulse chirped pulse amplification beams. This gives the UK a unique combined long pulse/short pulse laser capability which is not only available to AWE personnel but also gives access to our international partners and visiting UK academia. The ORION laser facility is equipped with a comprehensive suite of some 45 diagnostics covering optical, particle, and x-ray diagnostics all able to image the laser target interaction point. This paper focuses on a small selection of these diagnostics.

  4. ORION laser target diagnostics.

    Science.gov (United States)

    Bentley, C D; Edwards, R D; Andrew, J E; James, S F; Gardner, M D; Comley, A J; Vaughan, K; Horsfield, C J; Rubery, M S; Rothman, S D; Daykin, S; Masoero, S J; Palmer, J B; Meadowcroft, A L; Williams, B M; Gumbrell, E T; Fyrth, J D; Brown, C R D; Hill, M P; Oades, K; Wright, M J; Hood, B A; Kemshall, P

    2012-10-01

    The ORION laser facility is one of the UK's premier laser facilities which became operational at AWE in 2010. Its primary mission is one of stockpile stewardship, ORION will extend the UK's experimental plasma physics capability to the high temperature, high density regime relevant to Atomic Weapons Establishment's (AWE) program. The ORION laser combines ten laser beams operating in the ns regime with two sub ps short pulse chirped pulse amplification beams. This gives the UK a unique combined long pulse/short pulse laser capability which is not only available to AWE personnel but also gives access to our international partners and visiting UK academia. The ORION laser facility is equipped with a comprehensive suite of some 45 diagnostics covering optical, particle, and x-ray diagnostics all able to image the laser target interaction point. This paper focuses on a small selection of these diagnostics.

  5. Target Diagnostic Control System Implementation for the National Ignition Facility

    International Nuclear Information System (INIS)

    Shelton, R.T.; Kamperschroer, J.H.; Lagin, L.J.; Nelson, J.R.; O'Brien, D.W.

    2010-01-01

    The extreme physics of targets shocked by NIF's 192-beam laser are observed by a diverse suite of diagnostics. Many diagnostics are being developed by collaborators at other sites, but ad hoc controls could lead to unreliable and costly operations. A Diagnostic Control System (DCS) framework for both hardware and software facilitates development and eases integration. Each complex diagnostic typically uses an ensemble of electronic instruments attached to sensors, digitizers, cameras, and other devices. In the DCS architecture each instrument is interfaced to a low-cost Windows XP processor and Java application. Each instrument is aggregated with others as needed in the supervisory system to form an integrated diagnostic. The Java framework provides data management, control services and operator GUI generation. DCS instruments are reusable by replication with reconfiguration for specific diagnostics in XML. Advantages include minimal application code, easy testing, and high reliability. Collaborators save costs by assembling diagnostics with existing DCS instruments. This talk discusses target diagnostic instrumentation used on NIF and presents the DCS architecture and framework.

  6. Nova target diagnostics control system

    International Nuclear Information System (INIS)

    Severyn, J.R.

    1985-01-01

    During the past year the Nova target diagnostics control system was finished and put in service. The diagnostics loft constructed to the north of the target room provides the environmental conditions required to collect reliable target diagnostic data. These improvements include equipment cooling and isolation of the power source with strict control of instrumentation grounds to eliminate data corruption due to electromagnetic pulses from the laser power-conditioning system or from target implosion effects

  7. Target diagnostic control system implementation for the National Ignition Facility (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Shelton, R. T.; Kamperschroer, J. H.; Lagin, L. J.; Nelson, J. R.; O' Brien, D. W. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2010-10-15

    The extreme physics of targets shocked by NIF's 192-beam laser is observed by a diverse suite of diagnostics. Many diagnostics are being developed by collaborators at other sites, but ad hoc controls could lead to unreliable and costly operations. A diagnostic control system (DCS) framework for both hardware and software facilitates development and eases integration. Each complex diagnostic typically uses an ensemble of electronic instruments attached to sensors, digitizers, cameras, and other devices. In the DCS architecture each instrument is interfaced to a low-cost WINDOWS XP processor and JAVA application. Each instrument is aggregated with others as needed in the supervisory system to form an integrated diagnostic. The JAVA framework provides data management, control services, and operator graphical user interface generation. DCS instruments are reusable by replication with reconfiguration for specific diagnostics in extensible markup language. Advantages include minimal application code, easy testing, and high reliability. Collaborators save costs by assembling diagnostics with existing DCS instruments. This talk discusses target diagnostic instrumentation used on NIF and presents the DCS architecture and framework.

  8. Target diagnostic control system implementation for the National Ignition Facility (invited)

    International Nuclear Information System (INIS)

    Shelton, R. T.; Kamperschroer, J. H.; Lagin, L. J.; Nelson, J. R.; O'Brien, D. W.

    2010-01-01

    The extreme physics of targets shocked by NIF's 192-beam laser is observed by a diverse suite of diagnostics. Many diagnostics are being developed by collaborators at other sites, but ad hoc controls could lead to unreliable and costly operations. A diagnostic control system (DCS) framework for both hardware and software facilitates development and eases integration. Each complex diagnostic typically uses an ensemble of electronic instruments attached to sensors, digitizers, cameras, and other devices. In the DCS architecture each instrument is interfaced to a low-cost WINDOWS XP processor and JAVA application. Each instrument is aggregated with others as needed in the supervisory system to form an integrated diagnostic. The JAVA framework provides data management, control services, and operator graphical user interface generation. DCS instruments are reusable by replication with reconfiguration for specific diagnostics in extensible markup language. Advantages include minimal application code, easy testing, and high reliability. Collaborators save costs by assembling diagnostics with existing DCS instruments. This talk discusses target diagnostic instrumentation used on NIF and presents the DCS architecture and framework.

  9. Shiva and Argus target diagnostics vacuum systems

    International Nuclear Information System (INIS)

    Glaros, S.S.; Mayo, S.E.; Campbell, D.; Holeman, D.

    1978-09-01

    The normal operation of LLL's Argus and Shiva laser irradiation facilities demand a main vacuum system for the target chamber and a separate local vacuum system for each of the larger appendage dianostics. This paper will describe the Argus and Shiva main vacuum systems, their respective auxiliary vacuum systems and the individual diagnostics with their respective special vacuum requirements and subsequent vacuum systems. Our latest approach to automatic computer-controlled vacuum systems will be presented

  10. Target Diagnostics Supports NIF's Path to Ignition

    International Nuclear Information System (INIS)

    Shelton, R.

    2011-01-01

    The physics requirements derived from the National Ignition Facility (NIF) experimental campaigns are leading to a wide variety of target diagnostics. Software development for the control and analysis of these diagnostics is included in the NIF Integrated Computer Control System, Diagnostic Control System and Data Visualization. These projects implement the configuration, controls, data analysis and visual representation of most of these diagnostics. To date, over 40 target diagnostics have been developed to support NIF experiments. In 2011 diagnostics were developed or enhanced to measure Ignition performance in a high neutron yield environment. Performance is optimized around four key variables: Adiabat (a) which is the strength and timing of four shocks delivered to the target, Velocity (V) of the imploding target, Mix (M) is the uniformity of the burn, and the Shape (S) of the imploding Deuterium Tritium (DT) hot spot. The diagnostics used to measure each of these parameters is shown in figure 1. Adiabat is measured using the Velocity Interferometer System for Any Reflector (VISAR) diagnostic consisting of three streak cameras. To provide for more accurate adiabat measurements the VISAR streak cameras were enhanced in FY11 with a ten comb fiducial signal controller to allow for post shot correction of the streak camera sweep non-linearity. Mix is measured by the Neutron Time of Flight (NTOF) and Radiochemical Analysis of Gaseous Samples (RAGS) diagnostics. To accommodate high neutron yield shots, NTOF diagnostic controls are being modified to use Mach Zehnder interferometer signals to allow the digitizers to be moved from near the target chamber to the neutron shielded diagnostic mezzanine. In December 2011 the first phase of RAGS diagnostic commissioning will be completed. This diagnostic will analyze the tracers that are added to NIF target capsules that undergo nuclear reactions during the shot. These gases are collected and purified for nuclear counting by

  11. Los Alamos contribution to target diagnostics on the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Mack, J.M.; Baker, D.A.; Caldwell, S.E. [and others

    1994-07-01

    The National Ignition Facility (NIF) will have a large suite of sophisticated target diagnostics. This will allow thoroughly diagnosed experiments to be performed both at the ignition and pre-ignition levels. As part of the national effort Los Alamos National Laboratory will design, construct and implement a number of diagnostics for the NIF. This paper describes Los Alamos contributions to the ``phase I diagnostics.`` Phase I represents the most fundamental and basic measurement systems that will form the core for most work on the NIF. The Los Alamos effort falls into four categories: moderate to hard X-ray (time resolved imaging neutron spectroscopy- primarily with neutron time of flight devices; burn diagnostics utilizing gamma ray measurements; testing measurement concepts on the TRIDENT laser system at Los Alamos. Because of the high blast, debris and radiation environment, the design of high resolution X-ray imaging systems present significant challenges. Systems with close target proximity require special protection and methods for such protection is described. The system design specifications based on expected target performance parameters is also described. Diagnosis of nuclear yield and burn will be crucial to the NIF operation. Nuclear reaction diagnosis utilizing both neutron and gamma ray detection is discussed. The Los Alamos TRIDENT laser system will be used extensively for the development of new measurement concepts and diagnostic instrumentation. Some its potential roles in the development of diagnostics for NIF are given.

  12. Los Alamos contribution to target diagnostics on the National Ignition Facility

    International Nuclear Information System (INIS)

    Mack, J.M.; Baker, D.A.; Caldwell, S.E.

    1994-01-01

    The National Ignition Facility (NIF) will have a large suite of sophisticated target diagnostics. This will allow thoroughly diagnosed experiments to be performed both at the ignition and pre-ignition levels. As part of the national effort Los Alamos National Laboratory will design, construct and implement a number of diagnostics for the NIF. This paper describes Los Alamos contributions to the ''phase I diagnostics.'' Phase I represents the most fundamental and basic measurement systems that will form the core for most work on the NIF. The Los Alamos effort falls into four categories: moderate to hard X-ray (time resolved imaging neutron spectroscopy- primarily with neutron time of flight devices; burn diagnostics utilizing gamma ray measurements; testing measurement concepts on the TRIDENT laser system at Los Alamos. Because of the high blast, debris and radiation environment, the design of high resolution X-ray imaging systems present significant challenges. Systems with close target proximity require special protection and methods for such protection is described. The system design specifications based on expected target performance parameters is also described. Diagnosis of nuclear yield and burn will be crucial to the NIF operation. Nuclear reaction diagnosis utilizing both neutron and gamma ray detection is discussed. The Los Alamos TRIDENT laser system will be used extensively for the development of new measurement concepts and diagnostic instrumentation. Some its potential roles in the development of diagnostics for NIF are given

  13. METAL:LIC target failure diagnostics by means of liquid metal loop vibrations monitoring

    International Nuclear Information System (INIS)

    Dementjevs, S.; Barbagallo, F.; Wohlmuther, M.; Thomsen, K.; Zik, A.; Nikoluskins, R.

    2014-01-01

    A target mock-up, developed as an European Spallation Source comparative solution, (METAL:LIC) has been tested in a dedicated lead bismuth eutectic (LBE) loop in the Institute of Physics at the University of Latvia. In particular, the feasibility of diagnostic vibration monitoring has been investigated. The loop parameters were: operation temperature 300°C; tubing ∅100 mm, overall length 8 m; electromagnetic pump based on permanent magnets, flow rate 180 kg/s. With sufficient static pressure of a few bars, cavitation was avoided. The vibrations in the loop were measured and analyzed. Several vibrational characteristics of the set-up were derived including resonance frequencies and the dependence of excited vibrations on flow conditions and the pump rotation speed. A high sensitivity to obstructions in the loop has been confirmed, and several indicators for target failure diagnostics were tested and compared. A problem in the electromagnetic pump's gear box has been detected in a very early state long before it manifested itself in the operation of the loop. The vibration monitoring has been demonstrated as a sensitive and reliable probe for the target failure diagnostics. (author)

  14. Use of the target diagnostic control system in the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Shelton, R; Lagin, L; Nelson, J

    2011-07-25

    The extreme physics of targets shocked by NIF's 192-beam laser are observed by a diverse suite of diagnostics including optical backscatter, time-integrated, time resolved and gated X-ray sensors, laser velocity interferometry, and neutron time of flight. Diagnostics to diagnose fusion ignition implosion and neutron emissions have been developed. A Diagnostic Control System (DCS) for both hardware and software facilitates development and eases integration. Each complex diagnostic typically uses an ensemble of electronic instruments attached to sensors, digitizers, cameras, and other devices. In the DCS architecture each instrument is interfaced to a low-cost Window XP processor and Java application. Instruments are aggregated as needed in the supervisory system to form an integrated diagnostic. The Java framework provides data management, control services and operator GUI generation. During the past several years, over thirty-six diagnostics have been deployed using this architecture in support of the National Ignition Campaign (NIC). The DCS architecture facilitates the expected additions and upgrades to diagnostics as more experiments are performed. This paper presents the DCS architecture, framework and our experiences in using it during the NIC to operate, upgrade and maintain a large set of diagnostic instruments.

  15. Use of the target diagnostic control system in the National Ignition Facility

    International Nuclear Information System (INIS)

    Shelton, R.; Lagin, L.; Nelson, J.

    2011-01-01

    The extreme physics of targets shocked by NIF's 192-beam laser are observed by a diverse suite of diagnostics including optical backscatter, time-integrated, time resolved and gated X-ray sensors, laser velocity interferometry, and neutron time of flight. Diagnostics to diagnose fusion ignition implosion and neutron emissions have been developed. A Diagnostic Control System (DCS) for both hardware and software facilitates development and eases integration. Each complex diagnostic typically uses an ensemble of electronic instruments attached to sensors, digitizers, cameras, and other devices. In the DCS architecture each instrument is interfaced to a low-cost Window XP processor and Java application. Instruments are aggregated as needed in the supervisory system to form an integrated diagnostic. The Java framework provides data management, control services and operator GUI generation. During the past several years, over thirty-six diagnostics have been deployed using this architecture in support of the National Ignition Campaign (NIC). The DCS architecture facilitates the expected additions and upgrades to diagnostics as more experiments are performed. This paper presents the DCS architecture, framework and our experiences in using it during the NIC to operate, upgrade and maintain a large set of diagnostic instruments.

  16. Target Diagnostic Instrument-Based Controls Framework for the National Ignition Facility

    International Nuclear Information System (INIS)

    Shelton, R; O'Brien, D; Nelson, J; Kamperschroer, J

    2007-01-01

    NIF target diagnostics are being developed to observe and measure the extreme physics of targets irradiated by the 192-beam laser. The response time of target materials can be on the order of 100ps--the time it takes light to travel 3 cm--temperatures more than 100 times hotter than the surface of the sun, and pressures that exceed 109 atmospheres. Optical and x-ray diagnostics were developed and fielded to observe and record the results of the first 4-beam experiments at NIF. Hard and soft x-ray spectra were measured, and time-integrated and gated x-ray images of hydrodynamics experiments were recorded. Optical diagnostics recorded backscatter from the target, and VISAR laser velocimetry measurements were taken of laser-shocked target surfaces. Additional diagnostics are being developed and commissioned to observe and diagnose ignition implosions, including various neutron and activation diagnostics. NIF's diagnostics are being developed at LLNL and with collaborators at other sites. To accommodate the growing number of target diagnostics, an Instrument-Based Controls hardware-software framework has been developed to facilitate development and ease integration into the NIF Integrated Computer Control System (ICCS). Individual WindowsXP PC controllers for each digitizer, power supply and camera (i.e., instruments) execute controls software unique to each instrument model. Each hardware-software controller manages a single instrument, in contrast to the complexity of combining all the controls software needed for a diagnostic into a single controller. Because of this simplification, controllers can be more easily tested on the actual hardware, evaluating all normal and off-normal conditions. Each target diagnostic is then supported by a number of instruments, each with its own hardware-software instrument-based controller. Advantages of the instrument-based control architecture and framework include reusability, testability, and improved reliability of the deployed

  17. Target Diagnostic Instrument-Based Controls Framework for the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Shelton, R; O' Brien, D; Nelson, J; Kamperschroer, J

    2007-05-07

    NIF target diagnostics are being developed to observe and measure the extreme physics of targets irradiated by the 192-beam laser. The response time of target materials can be on the order of 100ps--the time it takes light to travel 3 cm--temperatures more than 100 times hotter than the surface of the sun, and pressures that exceed 109 atmospheres. Optical and x-ray diagnostics were developed and fielded to observe and record the results of the first 4-beam experiments at NIF. Hard and soft x-ray spectra were measured, and time-integrated and gated x-ray images of hydrodynamics experiments were recorded. Optical diagnostics recorded backscatter from the target, and VISAR laser velocimetry measurements were taken of laser-shocked target surfaces. Additional diagnostics are being developed and commissioned to observe and diagnose ignition implosions, including various neutron and activation diagnostics. NIF's diagnostics are being developed at LLNL and with collaborators at other sites. To accommodate the growing number of target diagnostics, an Instrument-Based Controls hardware-software framework has been developed to facilitate development and ease integration into the NIF Integrated Computer Control System (ICCS). Individual WindowsXP PC controllers for each digitizer, power supply and camera (i.e., instruments) execute controls software unique to each instrument model. Each hardware-software controller manages a single instrument, in contrast to the complexity of combining all the controls software needed for a diagnostic into a single controller. Because of this simplification, controllers can be more easily tested on the actual hardware, evaluating all normal and off-normal conditions. Each target diagnostic is then supported by a number of instruments, each with its own hardware-software instrument-based controller. Advantages of the instrument-based control architecture and framework include reusability, testability, and improved reliability of the

  18. National Ignition Facility subsystem design requirements target diagnostics subsystem SSDR 1.8.3

    International Nuclear Information System (INIS)

    Lee, D.

    1996-01-01

    This SSDR establishes the performance, design, development and test requirements for the Target Experimental System's Diagnostic, WBS 1.8. 3. This includes the individual diagnostic components, the Target Diagnostic Data Acquisition System (Target DAS), the diagnostic vacuum system, the timing/fiducial system, and the EMI protection system

  19. Nanoparticle functionalization for brain targeting drug delivery and diagnostic

    DEFF Research Database (Denmark)

    Gomes, Maria João; Mendes, Bárbara; Martins, Susana

    2016-01-01

    carriers to cross the BBB and achieve brain, and their functionalization strategies are described; and finally the delivery of nanoparticles to the target moiety, as diagnostics or therapeutics. Therefore, this chapter is focused on how the nanoparticle surface may be functionalized for drug delivery......Nanobiotechnology has been demonstrated to be an efficient tool for targeted therapy as well as diagnosis, with particular emphasis on brain tumor and neurodegenerative diseases. On this regard, the aim of this chapter is focused on engineered nanoparticles targeted to the brain, so that they have...... and diagnostics. Furthermore, it is also mentioned that some BBB targets were already used as transport mediators to central nervous system by functionalization on nanoparticles. It summarizes the nanoparticles potential in therapeutics and molecular targeting to BBB, and also an approach of the nanoparticle...

  20. Implementation of Targeted Next Generation Sequencing in Clinical Diagnostics

    DEFF Research Database (Denmark)

    Larsen, Martin Jakob; Burton, Mark; Thomassen, Mads

    Accurate mutation detection is essential in clinical genetic diagnostics of monogenic hereditary diseases. Targeted next generation sequencing (NGS) provides a promising and cost-effective alternative to Sanger sequencing and MLPA analysis currently used in most diagnostic laboratories. One...... of mutation positive controls previously characterized by Sanger/MLPA analysis. Agilent SureSelect Target-Enrichment kits were used for capturing a set of genes associated with hereditary breast and ovarian cancer syndrome and a compilation of genes involved in multiple rare single gene disorders......, respectively. For diagnostics, the sequencing coverage is essential, wherefore a minimum coverage of 30x per nucleotide in the coding regions was used as our primary quality criterion. For the majority of the included genes, we obtained adequate gene coverage, in which we were able to detect 100% of the known...

  1. Bacterial proteases: targets for diagnostics and therapy

    NARCIS (Netherlands)

    Kaman, W.E.; Hays, J.P.; Endtz, H.P.; Bikker, F.J.

    2014-01-01

    Proteases are essential for the proliferation and growth of bacteria, and are also known to contribute to bacterial virulence. This makes them interesting candidates as diagnostic and therapeutic targets for infectious diseases. In this review, the authors discuss the most recent developments and

  2. Companion diagnostics for the targeted therapy of gastric cancer.

    Science.gov (United States)

    Yoo, Changhoon; Park, Young Soo

    2015-10-21

    Gastric cancer is the fourth most common type of cancer and represents a major cause of cancer-related deaths worldwide. With recent biomedical advances in our understanding of the molecular characteristics of gastric cancer, many genetic alterations have been identified as potential targets for its treatment. Multiple novel agents are currently under development as the demand for active agents that improve the survival of gastric cancer patients constantly increases. Based on lessons from previous trials of targeted agents, it is now widely accepted that the establishment of an optimal diagnostic test to select molecularly defined patients is of equal importance to the development of active agents against targetable genetic alterations. Herein, we highlight the current status and future perspectives of companion diagnostics in the treatment of gastric cancer.

  3. Cell targeting peptides as smart ligands for targeting of therapeutic or diagnostic agents: a systematic review.

    Science.gov (United States)

    Mousavizadeh, Ali; Jabbari, Ali; Akrami, Mohammad; Bardania, Hassan

    2017-10-01

    Cell targeting peptides (CTP) are small peptides which have high affinity and specificity to a cell or tissue targets. They are typically identified by using phage display and chemical synthetic peptide library methods. CTPs have attracted considerable attention as a new class of ligands to delivery specifically therapeutic and diagnostic agents, because of the fact they have several advantages including easy synthesis, smaller physical sizes, lower immunogenicity and cytotoxicity and their simple and better conjugation to nano-carriers and therapeutic or diagnostic agents compared to conventional antibodies. In this systematic review, we will focus on the basic concepts concerning the use of cell-targeting peptides (CTPs), following the approaches of selecting them from peptide libraries. We discuss several developed strategies for cell-specific delivery of different cargos by CTPs, which are designed for drug delivery and diagnostic applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. First Wall and Operational Diagnostics

    International Nuclear Information System (INIS)

    Lasnier, C; Allen, S; Boedo, J; Groth, M; Brooks, N; McLean, A; LaBombard, B; Sharpe, J; Skinner, C; Whyte, D; Rudakov, D; West, W; Wong, C

    2006-01-01

    In this chapter we review numerous diagnostics capable of measurements at or near the first wall, many of which contribute information useful for safe operation of a tokamak. There are sections discussing infrared cameras, visible and VUV cameras, pressure gauges and RGAs, Langmuir probes, thermocouples, and erosion and deposition measurements by insertable probes and quartz microbalance. Also discussed are dust measurements by electrostatic detectors, laser scattering, visible and IR cameras, and manual collection of samples after machine opening. In each case the diagnostic is discussed with a view toward application to a burning plasma machine such as ITER

  5. Nova diagnostics summary

    International Nuclear Information System (INIS)

    Slivinsky, V.W.; Drake, R.P.

    1985-01-01

    The authors intend that Nova be the best diagnosed ICF research facility in operation today. The authors experience in providing advanced diagnostics for previous laser systems will be extended at Nova, and will be challenged by the development of new instrumentation to diagnose the more advanced targets made possible by this powerful laser. Previous experience has shown that to understand target performance, the authors must have as complete a set of diagnostics as possible. The Nova diagnostics are divided into two sets: the basic set required for the initial Nova experiments and the more advanced set for later, generally more complex, experiments. The basic set will be operational for the first Nova shots; it was a Nova line item funded with Nova construction money. This basic set is presented in a table

  6. The wireless diagnostic system for motor operated valves

    International Nuclear Information System (INIS)

    Ito, Haruo; Akiyama, Michiaki; Suzuki, Syunichi

    2010-01-01

    To aim at maintenance optimization, a motor operated valve (MOV) diagnostic system called 'MOVDAS' has been developed by using new sensor technologies incorporating torque sensor into the MOV. It has been introduced into nuclear power plants operated by Japan Atomic Power Company (JAPC) for the support of Condition Based Maintenance (CBM). This system, directly checking the torque behavior of the MOV, accurately diagnoses the condition of the MOV during plant operation. Further for the ease of data collection and manpower saving, the wireless diagnostic system based on MOVDAS utilizing Personal Handyphone System (PHS) has been recently introduced into nuclear power plants in JAPC. (author)

  7. Development of advanced diagnostic technologies for motor-operated valves

    International Nuclear Information System (INIS)

    Hegi, Kotaro; Shimizu, Shunichi; Higuma, Koji; Nishino, Koji; Osaki, Kenji; Watanabe, Kazumi; Hamano, Frank

    2010-01-01

    As use of condition-based maintenance is allowed in the new regulatory inspection system employed in Japan's nuclear power plants in 2009, development of advanced diagnostic technologies for motor-operated valves (MOVs) is now required. This report discusses advanced technologies in valve-setup verification, valve performance evaluation, monitoring of valve/actuator conditions by performance diagnostic system and moreover detection of stem crack by ultrasonic diagnostic system. (author)

  8. Application of diagnostics to determine motor operated valve operational readiness

    International Nuclear Information System (INIS)

    Eissenberg, D.M.

    1987-01-01

    ORNL has been carrying out an aging assessment of motor-operated valves (MOVs) with the primary objective of recommending diagnostic methods for detecting and trending aging. As a result of experimental investigations at ORNL, it was discovered that the motor current during a valve stroke was a very useful diagnostic parameter for detecting and trending many MOV drive train load variations. The motor current signatures were analyzed at four levels: mean value for a stroke, gross trends during a stroke, transients, and noise frequency spectra. Examples illustrating the use of this technique are presented. The use of motor current signature analysis was also shown to apply to other electric motor driven equipment. Future work includes developing a data base of MOV diagnostics, including criteria for determining the extent of degradation and application of the technique to other LWR motor driven safety equipment

  9. Application of diagnostics to determine motor-operated valve operational readiness

    International Nuclear Information System (INIS)

    Eissenberg, D.M.

    1986-01-01

    ORNL has been carrying out an aging assessment of motor-operated valves (MOVs) with the primary objective of recommending diagnostic methods for detecting and trending aging. As a result of experimental investigations at ORNL, it was discovered that the motor current during a valve stroke was a very useful diagnostic parameter for detecting and trending many MOV drive train load variations. The motor curent signatures were analyzed at four levels: mean value for a stroke, gross trends during a stroke, transients, and noise frequency spectra. Examples illustrating the use of this technique are presented. The use of motor current signature analysis was also shown to apply to other electric motor driven equipment. Future work includes developing a data base of MOV diagnostics, including criteria for determining the extent of degradation and application of the technique to other LWR motor driven safety equipment

  10. ISAC target operation with high proton currents

    CERN Document Server

    Dombsky, M; Schmor, P; Lane, M

    2003-01-01

    The TRIUMF-ISAC facility target stations were designed for ISOL target irradiations with up to 100 mu A proton beam currents. Since beginning operation in 1998, ISAC irradiation currents have progressively increased from initial values of approx 1 mu A to present levels of up to 40 mu A on refractory metal foil targets. In addition, refractory carbide targets have operated at currents of up to 15 mu A for extended periods. The 1-40 mu A operational regime is achieved by tailoring each target to the thermal requirements dictated by material properties such as beam power deposition, thermal conductivity and maximum operating temperature of the target material. The number of heat shields on each target can be varied in order to match the effective emissivity of the target surface for the required radiative power dissipation. Targets of different thickness, surface area and volume have been investigated to study the effect of diffusion and effusion delays on the yield of radioisotopes. For yields of short-lived p...

  11. Complete fabrication of target experimental chamber and implement initial target diagnostics to be used for the first target experiments in NDCX-1

    International Nuclear Information System (INIS)

    Bieniosek, F.M.; Bieniosek, F.M.; Dickinson, M.R.; Henestroza, E.; Katayanagi, T.; Jung, J.Y.; Lee, C.W.; Leitner, M.; Ni, P.; Roy, P.; Seidl, P.; Waldron, W.; Welch, D.

    2008-01-01

    The Heavy Ion Fusion Science Virtual National Laboratory (HIFS-VNL) has completed the fabrication of a new experimental target chamber facility for future Warm Dense Matter (WDM) experiments, and implemented initial target diagnostics to be used for the first target experiments in NDCX-1. The target chamber has been installed on the NDCX-I beamline. This achievement provides to the HIFS-VNL unique and state-of-the-art experimental capabilities in preparation for the planned target heating experiments using intense heavy ion beams

  12. Towards Verification of Operational Procedures Using Auto-Generated Diagnostic Trees

    Science.gov (United States)

    Kurtoglu, Tolga; Lutz, Robyn; Patterson-Hine, Ann

    2009-01-01

    The design, development, and operation of complex space, lunar and planetary exploration systems require the development of general procedures that describe a detailed set of instructions capturing how mission tasks are performed. For both crewed and uncrewed NASA systems, mission safety and the accomplishment of the scientific mission objectives are highly dependent on the correctness of procedures. In this paper, we describe how to use the auto-generated diagnostic trees from existing diagnostic models to improve the verification of standard operating procedures. Specifically, we introduce a systematic method, namely the Diagnostic Tree for Verification (DTV), developed with the goal of leveraging the information contained within auto-generated diagnostic trees in order to check the correctness of procedures, to streamline the procedures in terms of reducing the number of steps or use of resources in them, and to propose alternative procedural steps adaptive to changing operational conditions. The application of the DTV method to a spacecraft electrical power system shows the feasibility of the approach and its range of capabilities

  13. An Overview of the Target Fabrication Operations at Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    Hibbard, R L; Bono, M J

    2005-01-01

    The Target Engineering team at Lawrence Livermore National Laboratory (LLNL) builds precision laser targets for the National Ignition Facility (NIF) and the Omega Laser in Rochester, NY, and other experimental facilities. The physics requirements demand precision in these targets, which creates a constant need for innovative manufacturing processes. As experimental diagnostics improve, there is greater demand for precision in fabrication, assembly, metrology, and documentation of as-built targets. The team specializes in meso-scale fabrication with core competencies in diamond turning, assembly, and metrology. Figure 1 shows a typical diamond turning center. The team builds over 200 laser targets per year in batches of five to fifteen targets. Thus, all are small-lot custom builds, and most are novel designs requiring engineering and process development. Component materials are metals, polymers and low density aerogel foams. Custom fixturing is used to locate parts on the Diamond Turning Machines (DTM) and assembly stations. This ensures parts can be repeatably located during manufacturing operations. Most target builds involve a series of fabricating one surface with features and then relocating the components on another fixture to finish the opposite side of the component. These components are then assembled to complete multiple-component targets. These targets are typically built one at a time. Cost and efficiency are issues with production of targets, and the team is developing batch processing techniques to meet precision target specifications and cost goals. Three example target builds will highlight some of the fabrication and material issues faced at LLNL. A low temperature Rayleigh Taylor target shows how multiple precision targets can be fabricated out of a single large disk. The ignition double shell targets highlight the required manufacturing complexity. A low density aerogel target highlights some material handling and assembly issues. The metrology

  14. Impact of neutron and gamma radiation on the design of NIF diagnostics and target-bay systems

    Energy Technology Data Exchange (ETDEWEB)

    Eder, D.C.; Song, P.M.; Latkowski, J.F.; Reyes, S.; O' Brien, D.W.; Lee, F.D.; Young, B.K.; Koch, J.A.; Moran, M.J.; Watts, P.W.; Kimbrough, J.R.; Ng, E.W.; Landen, O.L.; MacGowan, B.J. [Lawrence Livermore National Lab., Livermore, CA (United States)

    2006-06-15

    The design of a wide range of components in and near the target bay of the National Ignition Facility (NIF) must allow for significant radiation from neutrons and gammas. Detailed 3-dimensional Monte Carlo simulations are critical to determine neutron and gamma fluxes for all target-bay components to allow optimization of location and auxiliary shielding. Demonstration of ignition poses unique challenges because of the large range (about 3 orders of magnitude) in the yield for any given attempt at ignition. Some diagnostics will provide data independent of yield, while others will provide data for lower yields and only survive high yields with little or no damage. In addition, for a given yield there is a more than 10 orders of magnitude range in neutron and gamma fluxes depending on location in the facility. For example, sensitive components in the diagnostic mezzanines and switchyards require auxiliary shielding for high-yield shots even though they are greater than 17 meters from target chamber center (TCC) and shielded by the 2 m-thick target-bay wall. In contrast, there are components 0.2 to 2 m from TCC with little or no shielding. For these components, particular attention is being made to use low-activation material because of the extremely high neutron loading levels. Many of the components closest to target center are designed to be single use to reduce worker dose from having to refurbish highly activated components. The cryogenic target positioner is an example where activation and ease of component replacement is an important part of the design. We are developing a design process for all target-bay systems that will assure reliable operation for the full range of planned yields. (authors)

  15. Impact of neutron and gamma radiation on the design of NIF diagnostics and target-bay systems

    Science.gov (United States)

    Eder, D. C.; Song, P. M.; Latkowski, J. F.; Reyes, S.; O'Brien, D. W.; Lee, F. D.; Young, B. K.; Koch, J. A.; Moran, M. J.; Watts, P. W.; Kimbrough, J. R.; Ng, E. W.; Landen, O. L.; MacGowan, B. J.

    2006-06-01

    The design of a wide range of components in and near the target bay of the National Ignition Facility (NIF) must allow for significant radiation from neutrons and gammas. Detailed 3D Monte Carlo simulations are critical to determine neutron and gamma fluxes for all target-bay components to allow optimization of location and auxiliary shielding. Demonstration of ignition poses unique challenges because of the large range (˜ 3 orders of magnitude) in the yield for any given attempt at ignition. Some diagnostics will provide data independent of yield, while others will provide data for lower yields and only survive high yields with little or no damage. In addition, for a given yield there is a more than 10 orders of magnitude range in neutron and gamma fluxes depending on location in the facility. For example, sensitive components in the diagnostic mezzanines and switchyards require auxiliary shielding for high-yield shots even though they are greater than 17 meters from target chamber center (TCC) and shielded by the 2 m-thick target-bay wall. In contrast, there are components 0.2 to 2 m from TCC with little or no shielding. For these components, particular attention is being made to use low-activation material because of the extremely high neutron loading levels. Many of the components closest to target center are designed to be single use to reduce worker dose from having to refurbish highly activated components. The cryogenic target positioner is an example where activation and ease of component replacement is an important part of the design. We are developing a design process for all target-bay systems that will assure reliable operation for the full range of planned yields.

  16. A novelty detection diagnostic methodology for gearboxes operating under fluctuating operating conditions using probabilistic techniques

    Science.gov (United States)

    Schmidt, S.; Heyns, P. S.; de Villiers, J. P.

    2018-02-01

    In this paper, a fault diagnostic methodology is developed which is able to detect, locate and trend gear faults under fluctuating operating conditions when only vibration data from a single transducer, measured on a healthy gearbox are available. A two-phase feature extraction and modelling process is proposed to infer the operating condition and based on the operating condition, to detect changes in the machine condition. Information from optimised machine and operating condition hidden Markov models are statistically combined to generate a discrepancy signal which is post-processed to infer the condition of the gearbox. The discrepancy signal is processed and combined with statistical methods for automatic fault detection and localisation and to perform fault trending over time. The proposed methodology is validated on experimental data and a tacholess order tracking methodology is used to enhance the cost-effectiveness of the diagnostic methodology.

  17. Targeted therapies with companion diagnostics in the management of breast cancer: current perspectives.

    Science.gov (United States)

    Myers, Meagan B

    2016-01-01

    Breast cancer is a multifaceted disease exhibiting both intertumoral and intratumoral heterogeneity as well as variable disease course. Over 2 decades of research has advanced the understanding of the molecular substructure of breast cancer, directing the development of new therapeutic strategies against these actionable targets. In vitro diagnostics, and specifically companion diagnostics, have been integral in the successful development and implementation of these targeted therapies, such as those directed against the human epidermal growth factor receptor 2. Lately, there has been a surge in the development, commercialization, and marketing of diagnostic assays to assist in breast cancer patient care. More recently, multigene signature assays, such as Oncotype DX, MammaPrint, and Prosigna, have been integrated in the clinical setting in order to tailor decisions on adjuvant endocrine and chemotherapy treatment. This review provides an overview of the current state of breast cancer management and the use of companion diagnostics to direct personalized approaches in the treatment of breast cancer.

  18. Influence of companion diagnostics on efficacy and safety of targeted anti-cancer drugs: systematic review and meta-analyses.

    Science.gov (United States)

    Ocana, Alberto; Ethier, Josee-Lyne; Díez-González, Laura; Corrales-Sánchez, Verónica; Srikanthan, Amirrtha; Gascón-Escribano, María J; Templeton, Arnoud J; Vera-Badillo, Francisco; Seruga, Bostjan; Niraula, Saroj; Pandiella, Atanasio; Amir, Eitan

    2015-11-24

    Companion diagnostics aim to identify patients that will respond to targeted therapies, therefore increasing the clinical efficacy of such drugs. Less is known about their influence on safety and tolerability of targeted anti-cancer agents. Randomized trials evaluating targeted agents for solid tumors approved by the US Food and Drug Administration since year 2000 were assessed. Odds ratios (OR) and and 95% confidence intervals (CI) were computed for treatment-related death, treatment-discontinuation related to toxicity and occurrence of any grade 3/4 adverse events (AEs). The 12 most commonly reported individual AEs were also explored. ORs were pooled in a meta-analysis. Analysis comprised 41 trials evaluating 28 targeted agents. Seventeen trials (41%) utilized companion diagnostics. Compared to control groups, targeted drugs in experimental arms were associated with increased odds of treatment discontinuation, grade 3/4 AEs, and toxic death irrespective of whether they utilized companion diagnostics or not. Compared to drugs without available companion diagnostics, agents with companion diagnostics had a lower magnitude of increased odds of treatment discontinuation (OR = 1.12 vs. 1.65, p diagnostics were greatest for diarrhea (OR = 1.29 vs. 2.43, p diagnostics are associated with improved safety, and tolerability. Differences were most marked for gastrointestinal, cutaneous and neurological toxicity.

  19. Air-operated valve diagnostics: requirements, programmes and experiences

    International Nuclear Information System (INIS)

    Cervilla, Remedios; Vallana, Fernando; Laporta, Jose Maria

    2014-01-01

    The aim of this paper is to present some elements in the field of air-operated valve (AOV) diagnostics from the perspective of Tecnatom, as a testing services provider in the national and international nuclear park. Throughout the following lines, we summarize the regulatory framework existing in Spain and the current practices in Spanish nuclear power plants regarding the AOV programs, the role of Tecnatom as a service provider and our testing techniques. Finally, a real test case is presented, to illustrate the value of diagnostic as predictive maintenance and early degradation detection tool. (authors)

  20. Supervisory Control and Diagnostics System Distributed Operating System

    International Nuclear Information System (INIS)

    McGoldrick, P.R.

    1979-01-01

    This paper contains a description of the Supervisory Control and Diagnostics System (SCDS) Distributed Operating System. The SCDS consists of nine 32-bit minicomputers with shared memory. The system's main purpose is to control a large Mirror Fusion Test Facility

  1. Application of diagnostics to determine operational readiness of aged motor-operated valves

    International Nuclear Information System (INIS)

    Eissenberg, D.M.

    1987-01-01

    Oak Ridge National Laboratory (ORNL) has been carrying out an aging assessment of motor-operated valves (MOVs) with the primary objective of recommending diagnostic methods for detecting and trending aging. As a result of experimental investigations at ORNL, it was discovered that the motor current during a valve stroke was a very useful diagnostic parameter for detecting and trending many MOV drive train load variations. The motor current signatures were analyzed at four levels: mean value for a stroke, gross trends during a stroke, transients, and noise frequency spectra. Examples illustrating the use of this technique are presented. The use of motor current signature analysis was also shown to apply to other electric motor driven equipment. Future work includes developing a data base of MOV diagnostics, including criteria for determining the extent of degradation and application of the technique to other LWR motor driven safety equipment

  2. Shiva optical diagnostics

    International Nuclear Information System (INIS)

    Rienecker, F.; Kobierecki, M.; Ozarski, R.; Seppala, L.; Manes, K.; Merritt, B.

    1977-01-01

    In the laser fusion program at Lawrence Livermore Laboratory, no target experiment is complete unless it is complemented by careful measurements of the laser pulse that irradiates the target. For this purpose, an incident beam diagnostics (IBD) package has been designed for the Shiva laser. The package will furnish data on items such as the total energy and the focusable energy out of the laser chain, and the spatial and temporal energy and power distribution at the target plane. Understanding laser-plasma interactions requires knowledge of the amount of 1.06 μm light energy that is scattered in various directions from the target. The light energy that is scattered toward the beam focusing lens is analyzed by a reflected beam diagnostic (RBD) package containing a calorimeter, a multiple image camera and a TV camera. This paper describes the detailed design and operation of the IBD and RBD packages as tools to align spatial filters and targets, as well as to diagnose the laser beams and target reflectivity

  3. Diagnostic yield of molecular autopsy in patients with sudden arrhythmic death syndrome using targeted exome sequencing

    DEFF Research Database (Denmark)

    Nunn, Laurence M; Lopes, Luis R; Syrris, Petros

    2016-01-01

    AIMS: The targeted genetic screening of Sudden Arrhythmic Death Syndrome (SADS) probands in a molecular autopsy has a diagnostic yield of up to 35%. Exome sequencing has the potential to improve this yield. The primary aim of this study is to examine the feasibility and diagnostic utility...... of targeted exome screening in SADS victims, utilizing familial clinical screening whenever possible. METHODS AND RESULTS: To determine the feasibility and diagnostic yield of targeted exome sequencing deoxyribonucleic acid (DNA) was isolated from 59 SADS victims (mean age 25 years, range 1-51 years...... previously published rare (0.02-0.5%) candidate mutations-a total yield of 29%. Co-segregation fully confirmed two private SCN5A Na channel mutations. Variants of unknown significance were detected in a further 34% of probands. CONCLUSION: Molecular autopsy using targeted exome sequencing has a relatively...

  4. Diagnostics design for steady-state operation of the Wendelstein 7-X stellarator

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, R.; Baldzuhn, J.; Biedermann, C.; Burhenn, R.; Bozhenkov, S.; Cantarini, J.; Dreier, H.; Endler, M.; Hartfuss, H.-J.; Hildebrandt, D.; Hirsch, M.; Jakubowski, M.; Kornejev, P.; Krychowiak, M.; Laqua, H. P.; Laux, M.; Pasch, E.; Richert, T.; Schneider, W.; Svensson, J. [Max-Planck-Institute fuer Plasmaphysik, EURATOM Association, Greifswald D-1749 (Germany); and others

    2010-10-15

    The status of the diagnostic developments for the quasistationary operable stellarator Wendelstein 7-X (maximum pulse length of 30 min at 10 MW ECRH heating at 140 GHz) will be reported on. Significant emphasis is being given to the issue of ECRH stray radiation shielding of in-vessel diagnostic components, which will be critical at high density operation requiring O2 and OXB heating.

  5. Dounreay Shuffler diagnostic software operations manual

    International Nuclear Information System (INIS)

    Eccleston, G.W.; Stuewe, B.; Klosterbuer, S.; Van Lyssel, T.

    1985-07-01

    This operations manual describes the test software for the Dounreay Shuffler. The Shuffler is an assay system, controlled by a Commodore PET computer, that measures the plutonium content in leached hulls at the fuel reprocessing plant in Dounreay, Scotland. The Shuffler contains a 252 Cf neutron source that is moved between storage and irradiation locations to obtain measurement data. A stepping motor control (SMC) module operates the Shuffler and accepts commands from the PET to move the source. This manual briefly describes the Shuffler and provides details on running and using the diagnostic software program. The communications protocol for message transmittal between the PET and SMC is defined and a detailed example of message sending is presented in an appendix

  6. A Three-Dimensional Receiver Operator Characteristic Surface Diagnostic Metric

    Science.gov (United States)

    Simon, Donald L.

    2011-01-01

    Receiver Operator Characteristic (ROC) curves are commonly applied as metrics for quantifying the performance of binary fault detection systems. An ROC curve provides a visual representation of a detection system s True Positive Rate versus False Positive Rate sensitivity as the detection threshold is varied. The area under the curve provides a measure of fault detection performance independent of the applied detection threshold. While the standard ROC curve is well suited for quantifying binary fault detection performance, it is not suitable for quantifying the classification performance of multi-fault classification problems. Furthermore, it does not provide a measure of diagnostic latency. To address these shortcomings, a novel three-dimensional receiver operator characteristic (3D ROC) surface metric has been developed. This is done by generating and applying two separate curves: the standard ROC curve reflecting fault detection performance, and a second curve reflecting fault classification performance. A third dimension, diagnostic latency, is added giving rise to 3D ROC surfaces. Applying numerical integration techniques, the volumes under and between the surfaces are calculated to produce metrics of the diagnostic system s detection and classification performance. This paper will describe the 3D ROC surface metric in detail, and present an example of its application for quantifying the performance of aircraft engine gas path diagnostic methods. Metric limitations and potential enhancements are also discussed

  7. Gaseous laser targets and optical diagnostics for studying compressible hydrodynamic instabilities

    International Nuclear Information System (INIS)

    Edwards, J M; Robey, H; Mackinnon, A

    2001-01-01

    Explore the combination of optical diagnostics and gaseous targets to obtain important information about compressible turbulent flows that cannot be derived from traditional laser experiments for the purposes of V and V of hydrodynamics models and understanding scaling. First year objectives: Develop and characterize blast wave-gas jet test bed; Perform single pulse shadowgraphy of blast wave interaction with turbulent gas jet as a function of blast wave Mach number; Explore double pulse shadowgraphy and image correlation for extracting velocity spectra in the shock-turbulent flow interaction; and Explore the use/adaptation of advanced diagnostics

  8. Incremental diagnostic value of targeted biopsy using mpMRI-TRUS fusion versus 14-fragments prostatic biopsy. A prospective controlled study

    International Nuclear Information System (INIS)

    Mariotti, Guilherme C.; Falsarella, Priscila M.; Garcia, Rodrigo G.; Queiroz, Marcos R.G.; Lemos, Gustavo C.; Baroni, Ronaldo H.

    2018-01-01

    To compare the incremental diagnostic value of targeted biopsy using real-time multiparametric magnetic resonance imaging and transrectal ultrasound (mpMRI-TRUS) fusion to conventional 14-cores biopsy. Uni-institutional, institutional review board (IRB) approved prospective blinded study comparing TRUS-guided random and targeted biopsy using mpMRI-TRUS fusion, in 100 consecutive men. We included men with clinical-laboratorial suspicious for prostate cancer and Likert score ≥ 3 mp-MRI. Patients previously diagnosed with prostate cancer were excluded. All patients were submitted to 14-cores TRUS-guided biopsy (mpMRI data operator-blinded), followed by targeted biopsy using mpMRI-TRUS fusion. There was an overall increase in cancer detection rate, from 56% with random technique to 62% combining targeted biopsy using mpMRI-TRUS fusion; incremental diagnosis was even more relevant for clinically significant lesions (Gleason ≥ 7), diagnosing 10% more clinically significant lesions with fusion biopsy technique. Diagnosis upgrade occurred in 5 patients that would have negative results in random biopsies and had clinically significant tumours with the combined technique, and in 5 patients who had the diagnosis of significant tumours after fusion biopsy and clinically insignificant tumours in random biopsies(p=0.0010). Targeted biopsy using mpMRI-TRUS fusion has incremental diagnostic value in comparison to conventional random biopsy, better detecting clinically significant prostate cancers. (orig.)

  9. Incremental diagnostic value of targeted biopsy using mpMRI-TRUS fusion versus 14-fragments prostatic biopsy. A prospective controlled study

    Energy Technology Data Exchange (ETDEWEB)

    Mariotti, Guilherme C.; Falsarella, Priscila M.; Garcia, Rodrigo G.; Queiroz, Marcos R.G. [Hospital Israelita Albert Einstein, Department of Interventional Radiology, Sao Paulo (Brazil); Lemos, Gustavo C. [Hospital Israelita Albert Einstein, Department of Urology, Sao Paulo (Brazil); Baroni, Ronaldo H. [Hospital Israelita Albert Einstein, Department of Radiology, Sao Paulo (Brazil)

    2018-01-15

    To compare the incremental diagnostic value of targeted biopsy using real-time multiparametric magnetic resonance imaging and transrectal ultrasound (mpMRI-TRUS) fusion to conventional 14-cores biopsy. Uni-institutional, institutional review board (IRB) approved prospective blinded study comparing TRUS-guided random and targeted biopsy using mpMRI-TRUS fusion, in 100 consecutive men. We included men with clinical-laboratorial suspicious for prostate cancer and Likert score ≥ 3 mp-MRI. Patients previously diagnosed with prostate cancer were excluded. All patients were submitted to 14-cores TRUS-guided biopsy (mpMRI data operator-blinded), followed by targeted biopsy using mpMRI-TRUS fusion. There was an overall increase in cancer detection rate, from 56% with random technique to 62% combining targeted biopsy using mpMRI-TRUS fusion; incremental diagnosis was even more relevant for clinically significant lesions (Gleason ≥ 7), diagnosing 10% more clinically significant lesions with fusion biopsy technique. Diagnosis upgrade occurred in 5 patients that would have negative results in random biopsies and had clinically significant tumours with the combined technique, and in 5 patients who had the diagnosis of significant tumours after fusion biopsy and clinically insignificant tumours in random biopsies(p=0.0010). Targeted biopsy using mpMRI-TRUS fusion has incremental diagnostic value in comparison to conventional random biopsy, better detecting clinically significant prostate cancers. (orig.)

  10. Development of wide area environment accelerator operation and diagnostics method

    Science.gov (United States)

    Uchiyama, Akito; Furukawa, Kazuro

    2015-08-01

    Remote operation and diagnostic systems for particle accelerators have been developed for beam operation and maintenance in various situations. Even though fully remote experiments are not necessary, the remote diagnosis and maintenance of the accelerator is required. Considering remote-operation operator interfaces (OPIs), the use of standard protocols such as the hypertext transfer protocol (HTTP) is advantageous, because system-dependent protocols are unnecessary between the remote client and the on-site server. Here, we have developed a client system based on WebSocket, which is a new protocol provided by the Internet Engineering Task Force for Web-based systems, as a next-generation Web-based OPI using the Experimental Physics and Industrial Control System Channel Access protocol. As a result of this implementation, WebSocket-based client systems have become available for remote operation. Also, as regards practical application, the remote operation of an accelerator via a wide area network (WAN) faces a number of challenges, e.g., the accelerator has both experimental device and radiation generator characteristics. Any error in remote control system operation could result in an immediate breakdown. Therefore, we propose the implementation of an operator intervention system for remote accelerator diagnostics and support that can obviate any differences between the local control room and remote locations. Here, remote-operation Web-based OPIs, which resolve security issues, are developed.

  11. Development of wide area environment accelerator operation and diagnostics method

    Directory of Open Access Journals (Sweden)

    Akito Uchiyama

    2015-08-01

    Full Text Available Remote operation and diagnostic systems for particle accelerators have been developed for beam operation and maintenance in various situations. Even though fully remote experiments are not necessary, the remote diagnosis and maintenance of the accelerator is required. Considering remote-operation operator interfaces (OPIs, the use of standard protocols such as the hypertext transfer protocol (HTTP is advantageous, because system-dependent protocols are unnecessary between the remote client and the on-site server. Here, we have developed a client system based on WebSocket, which is a new protocol provided by the Internet Engineering Task Force for Web-based systems, as a next-generation Web-based OPI using the Experimental Physics and Industrial Control System Channel Access protocol. As a result of this implementation, WebSocket-based client systems have become available for remote operation. Also, as regards practical application, the remote operation of an accelerator via a wide area network (WAN faces a number of challenges, e.g., the accelerator has both experimental device and radiation generator characteristics. Any error in remote control system operation could result in an immediate breakdown. Therefore, we propose the implementation of an operator intervention system for remote accelerator diagnostics and support that can obviate any differences between the local control room and remote locations. Here, remote-operation Web-based OPIs, which resolve security issues, are developed.

  12. Cancer-associated fibroblasts as target and tool in cancer therapeutics and diagnostics.

    Science.gov (United States)

    De Vlieghere, Elly; Verset, Laurine; Demetter, Pieter; Bracke, Marc; De Wever, Olivier

    2015-10-01

    Cancer-associated fibroblasts (CAFs) are drivers of tumour progression and are considered as a target and a tool in cancer diagnostic and therapeutic applications. An increased abundance of CAFs or CAF signatures are recognized as a bad prognostic marker in several cancer types. Tumour-environment biomimetics strongly improve our understanding of the communication between CAFs, cancer cells and other host cells. Several experimental drugs targeting CAFs are in clinical trials for multiple tumour entities; alternatively, CAFs can be exploited as a tool to characterize the functionality of circulating tumour cells or to capture them as a tool to prevent metastasis. The continuous interaction between tissue engineers, biomaterial experts and cancer researchers creates the possibility to biomimic the tumour-environment and provides new opportunities in cancer diagnostics and management.

  13. Targeting SR-BI for cancer diagnostics, imaging and therapy

    Directory of Open Access Journals (Sweden)

    Maneesha Amrita Rajora

    2016-09-01

    Full Text Available Scavenger receptor class B type I (SR-BI plays an important role in trafficking cholesteryl esters between the core of high density lipoprotein and the liver. Interestingly, this integral membrane protein receptor is also implicated in the metabolism of cholesterol by cancer cells, whereby overexpression of SR-BI has been observed in a number of tumours and cancer cell lines, including breast and prostate cancers. Consequently, SR-BI has recently gained attention as a cancer biomarker and exciting target for the direct cytosolic delivery of therapeutic agents. This brief review highlights these key developments in SR-BI-targeted cancer therapies and imaging probes. Special attention is given to the exploration of high density lipoprotein nanomimetic platforms that take advantage of upregulated SR-BI expression to facilitate targeted drug-delivery and cancer diagnostics, and promising future directions in the development of these agents.

  14. Technical Diagnostics of Ventilation Units for Energy Efficiency and Safety of Operation

    Directory of Open Access Journals (Sweden)

    Kuzin Evgeny

    2017-01-01

    Full Text Available The article considers the questions of application of technical diagnostics fan installations methods for providing safe operation, the system of the technical maintenance improvement and repair. Due to the feet that one of the most important aspects in fan operation in mining is energy efficiency and energy saving, the lack of the data in the control of the level in vibration of stationary sensors is shown. The necessity of taking into account the geometric parameters of the intake channel has been shown, and also the necessity of creation of the reference masks for the assessment of technical condition and energy efficiency when operating fan installations in mining. The results of technical diagnostics of the main fans using the methods of vibration diagnostics are provided. Aspects of vibration at characteristic points are shown. The necessity for further accumulation of data characterizing vibration for adjustment of the reference masks and more accurate detection of defects and deviations from the energy-efficient mode of operation of the fan installations is given.

  15. Technical Diagnostics of Ventilation Units for Energy Efficiency and Safety of Operation

    Science.gov (United States)

    Kuzin, Evgeny; Shahmanov, Vitality; Dubinkin, Dmitriy

    2017-11-01

    The article considers the questions of application of technical diagnostics fan installations methods for providing safe operation, the system of the technical maintenance improvement and repair. Due to the feet that one of the most important aspects in fan operation in mining is energy efficiency and energy saving, the lack of the data in the control of the level in vibration of stationary sensors is shown. The necessity of taking into account the geometric parameters of the intake channel has been shown, and also the necessity of creation of the reference masks for the assessment of technical condition and energy efficiency when operating fan installations in mining. The results of technical diagnostics of the main fans using the methods of vibration diagnostics are provided. Aspects of vibration at characteristic points are shown. The necessity for further accumulation of data characterizing vibration for adjustment of the reference masks and more accurate detection of defects and deviations from the energy-efficient mode of operation of the fan installations is given.

  16. Neutral Beam Source and Target Plasma for Development of a Local Electric Field Fluctuation Diagnostic

    Science.gov (United States)

    Bakken, M. R.; Burke, M. G.; Fonck, R. J.; Lewicki, B. T.; Rhodes, A. T.; Winz, G. R.

    2016-10-01

    A new diagnostic measuring local E-> (r , t) fluctuations is being developed for plasma turbulence studies in tokamaks. This is accomplished by measuring fluctuations in the separation of the π components in the Hα motional Stark spectrum. Fluctuations in this separation are expected to be Ẽ / ẼEMSE 10-3EMSE 10-3 . In addition to a high throughput, high speed spectrometer, the project requires a low divergence (Ω 0 .5°) , 80 keV, 2.5 A H0 beam and a target plasma test stand. The beam employs a washer-stack arc ion source to achieve a high species fraction at full energy. Laboratory tests of the ion source demonstrate repeatable plasmas with Te 10 eV and ne 1.6 ×1017 m-3, sufficient for the beam ion optics requirements. Te and ne scalings of the ion source plasma are presented with respect to operational parameters. A novel three-phase resonant converter power supply will provide 6 mA/cm2 of 80 keV H0 at the focal plane for pulse lengths up to 15 ms, with low ripple δV / 80 keV 0.05 % at 280 kHz. Diagnostic development and validation tests will be performed on a magnetized plasma test stand with 0.5 T field. The test chamber will utilize a washer-stack arc source to produce a target plasma comparable to edge tokamak plasmas. A bias-plate with programmable power supply will be used to impose Ẽ within the target plasma. Work supported by US DOE Grant DE-FG02-89ER53296.

  17. Development of PETAL diagnostics: PETAPhys project

    Science.gov (United States)

    Raffestin, D.; Boutoux, G.; Baggio, J.; Batani, D.; Blanchot, N.; Bretheau, D.; Hulin, S.; D'Humieres, E.; Granet, F.; Longhi, Th.; Meyer, Ch.; Moreno, Q.; Nuter, R.; Rault, J.; Tikhonchuk, V.; Universite de Bordeaux/Celia Team; CEA. DAM/Cesta Team

    2017-10-01

    Beginning of autumn 2017, PETAL, a Petawatt laser beam, will be operated for experiments on the LMJ facility at the CEA/ Cesta research center. The PETAPhys project provides a support to the qualification phase of the PETAL laser operation. Within the PETAPhys project, we are developing two simple and robust diagnostics permitting both to characterize the focal spot of the PETAL beam and to measure the hard X-ray spectrum at each shot. The first diagnostic consists in optical imaging of the PETAL beam focal spot in the spectral range of the second and third harmonic radiation emitted from the target. The second diagnostic is a hard X-ray dosimeter consisting in a stack of imaging plates (IP) and filters, either placed inside a re-entrant tube or inserted close to target. Numerical simulations as well as experiments on small scale facilities have been performed to design these diagnostics. If available, preliminary results from PETAL experiments will be discussed. We acknowledge the financial support from the French National Research Agency (ANR) in the framework of ``the investments for the future'' Programme IdEx Bordeaux-LAPHIA (ANR-10-IDEX-03-02).

  18. Polarized proton target-IV. Operations manual

    International Nuclear Information System (INIS)

    Hill, D.; Fletcher, O.; Moretti, A.; Onesto, F.

    1976-01-01

    Standard operating procedures are presented for the vacuum, cryogenic, and electronic systems of a polarized proton target. The systems are comprised of (1) a target cryostat; (2) a 4 He pumping system; (3) a 3 He pumping system; (4) a microwave system; (5) a magnet and power supply; (6) a computerized polarization monitor; and (7) miscellaneous auxiliary equipment

  19. Biomedical nanotechnology for molecular imaging, diagnostics, and targeted therapy.

    Science.gov (United States)

    Nie, Shuming

    2009-01-01

    Biomedical nanotechnology is a cross-disciplinary area of research in science, engineering and medicine with broad applications for molecular imaging, molecular diagnosis, and targeted therapy. The basic rationale is that nanometer-sized particles such as semiconductor quantum dots and iron oxide nanocrystals have optical, magnetic or structural properties that are not available from either molecules or bulk solids. When linked with biotargeting ligands such as monoclonal antibodies, peptides or small molecules, these nanoparticles can be used to target diseased cells and organs (such as malignant tumors and cardiovascular plaques) with high affinity and specificity. In the "mesoscopic" size range of 5-100 nm diameter, nanoparticles also have large surface areas and functional groups for conjugating to multiple diagnostic (e.g., optical, radioisotopic, or magnetic) and therapeutic (e.g., anticancer) agents.

  20. Target experimental area and systems of the Us national ignition facility

    International Nuclear Information System (INIS)

    Tobin, M.; Van Wonterghem, B.; MacGowan, B.J.; Hibbard, W.; Kalantar, D.; Lee, F.D.; Pittenger, L.; Wong, K.

    2000-01-01

    One of the major goals of the US National Ignition Facility is the demonstration of laser driven fusion ignition and burn of targets by inertial confinement and provide capability for a wide variety of high energy density physics experiments. The NIF target area houses the optical systems required to focus the 192 beamlets to a target precisely positioned at the center of the 10 meter diameter, 10-cm thick aluminum target chamber. The chamber serves as mounting surface for the 48 final optics assemblies, the target alignment and positioning equipment, and the target diagnostics. The internal surfaces of the chamber are protected by louvered steel beam dumps. The target area also provides the necessary shielding against target emission and environmental protection equipment. Despite its complexity, the design provides the flexibility to accommodate the needs of the various NIF user groups, such as direct and indirect drive irradiation geometries, modular final optics design, capability to handle cryogenic targets, and easily re-configurable diagnostic instruments. Efficient target area operations are ensured by using line-replaceable designs for systems requiring frequent inspection, maintenance and reconfiguration, such as the final optics, debris shields, phase plates and the diagnostic instruments. A precision diagnostic instrument manipulator (DIMS) allows fast removal and precise repositioning of diagnostic instruments. In addition we will describe several activities to enhance the target chamber availability, such as the target debris mitigation, the use of standard experimental configurations and the development of smart shot operations planning tools. (authors)

  1. Status of the diagnostics development for the first operation phase of the stellarator Wendelstein 7-X

    Energy Technology Data Exchange (ETDEWEB)

    König, R., E-mail: rlk@ipp.mpg.de; Biedermann, C.; Burhenn, R.; Endler, M.; Grulke, O.; Hathiramani, D.; Hirsch, M.; Jakubowski, M.; Kornejew, P.; Krychowiak, M.; Langenberg, A.; Laux, M.; Lorenz, A.; Otte, M.; Pasch, E.; Pedersen, T. S.; Schneider, W.; Thomsen, H.; Windisch, T.; Zhang, D. [Max Planck Institute for Plasma Physics, 17491 Greifswald (Germany); and others

    2014-11-15

    An overview of the diagnostics which are essential for the first operational phase of Wendelstein 7-X and the set of diagnostics expected to be ready for operation at this time are presented. The ongoing investigations of how to cope with high levels of stray Electron Cyclotron Resonance Heating (ECRH) radiation in the ultraviolet (UV)/visible/infrared (IR) optical diagnostics are described.

  2. NPP operator support in decision making - diagnostics of the operation failures using fuzzy logic

    International Nuclear Information System (INIS)

    Petruzela, I.

    2000-01-01

    In large complex systems such as nuclear power plants (NPP) and chemical industry plants, various subsystems fulfil the needs of process control and safety. Continued operation of these systems has both economic and safety implications. Electric utilities seek continuously to improve the operation of power generating stations. The improvement in the NPP Dukovany (4 x 440 MW) is related to the introduction of the plant to frequency control, meaning that the plant is operated not only in the base load operational mode but in the load follow mode as well. To achieve the improvement of plant operation, it was necessary to provide modifications to the plant control system, plant information system and diagnostics. This chapter deals with utilisation of artificial intelligence (AI) methods in implementation of these plant modifications. (orig.)

  3. Diagnostics Development towards Steady State Operation in Fusion Devices

    Energy Technology Data Exchange (ETDEWEB)

    Burhenn, R.; Baldzuhn, J.; Dreier, H.; Endler, M.; Hartfuss, H.J.; Hildebrandt, D.; Hirsch, M.; Koenig, R.; Kornejev, P.; Krychowiak, M.; Laqua, H.P.; Laux, M.; Oosterbeek, J.W.; Pasch, E.; Schneider, W.; Thomsen, H.; Weller, A.; Werner, A.; Wolf, R.; Zhang, D. [Max-Planck-Institute fuer Plasmaphysik, EURATOM Association, D-17491 Greifswald (Germany); Biel, W. [Institut fuer Energieforschung - Plasmaphysik, Forschungszentrum Juelich GmbH EURATOM Association, Trilateral Euregio Cluster, D-52425 Juelich (Germany)

    2011-07-01

    The stellarator Wendelstein 7-X (W7-X) is being presently under construction and is already equipped with superconducting coil systems and principally is capable of quasi-continuous operation. However, W7-X is faced with new enhanced technical requirements which have to be met by plasma facing components as well as the diagnostic systems in general. Depending on the available heating power, the continuous heat flux to plasma facing components during long pulse operation might lead to unacceptable local thermal overload and necessitates sufficient but often complicate active cooling precautions. Fusion devices with electron cyclotron frequency heating (ECRH) are concerned with significant stray radiation, depending on the chosen heating scheme and the plasma parameters. The required shielding is often not compatible with optimal UHV-consistent design and high intensity throughput. For machine safety, diagnostics are required which are able to identify enhanced plasma wall interaction on a fast time scale in order to prevent damage in time. For W7-X, video camera systems covering most of the inner wall, fast IR-camera systems with coating-resistant pinhole-optics for the observation of the divertor surface temperature and spectrometers with large spectral survey covering relevant spectral lines of all intrinsic impurities with sufficient spectral resolution and sensitivity are necessary. In combination with energy integrating but spatially resolving diagnostics like bolometers and soft-X cameras slow impurity accumulation phenomena on a time scale much larger than flat-top times typically achieved in short-pulse operation can be identified and a radiative plasma collapse possibly be avoided by counteractive measures. Longer port dimensions due to thermal insulation of the cryogenic coil system and high density operation with strong density gradients necessitate the choice of shorter wavelengths for interferometer laser beams. This complicates the avoidance of fringe

  4. Target experimental area and systems of the U.S. National Ignition Facility

    International Nuclear Information System (INIS)

    Tobin, M; Van Wonterghem, B; MacGowan, B J; Hibbard, W; Kalantar, D; Lee, F D; Pittenger, L; Wong, K

    1999-01-01

    One of the major goals of the US National Ignition Facility is the demonstration of laser driven fusion ignition and burn of targets by inertial confinement and provide capability for a wide variety of high energy density physics experiments. The NIF target area houses the optical systems required to focus the 192 beamlets to a target precisely positioned at the center of the 10 meter diameter, 10-cm thick aluminum target chamber. The chamber serves as mounting surface for the 48 final optics assemblies, the target alignment and positioning equipment, and the target diagnostics. The internal surfaces of the chamber are protected by louvered steel beam dumps. The target area also provides the necessary shielding against target emission and environmental protection equipment. Despite its complexity, the design provides the flexibility to accommodate the needs of the various NIF user groups, such as direct and indirect drive irradiation geometries, modular final optics design, capability to handle cryogenic targets, and easily re-configurable diagnostic instruments. Efficient target area operations are ensured by using line-replaceable designs for systems requiring frequent inspection, maintenance and reconfiguration, such as the final optics, debris shields, phase plates and the diagnostic instruments. A precision diagnostic instrument manipulator (DIMS) allows fast removal and precise repositioning of diagnostic instruments. In addition the authors describe several activities to enhance the target chamber availability, such as the target debris mitigation, the use of standard experimental configurations and the development of smart shot operations planning tools

  5. Diagnostic developments for quasicontinuous operation of the Wendelstein 7-X stellarator

    International Nuclear Information System (INIS)

    Koenig, R.; Cantarini, J.; Dreier, H.; Erckmann, V.; Hildebrandt, D.; Hirsch, M.; Kornejew, P.; Laux, M.; Laqua, H.; Pasch, E.; Thomsen, H.; Weller, A.; Werner, A.; Wolf, R.; Ye, M. Y.; Kocsis, G.; Recsei, S.; Zoletnik, S.; Szabo, V.

    2008-01-01

    The stellarator Wendelstein 7-X will allow for quasicontinuous operation with the duration only being limited to two 30 min discharges per day, at a continuous heating power of 10 MW electron cyclotron resonance heating (ECRH) at 140 GHz, by the capacity of the cooling water reservoir. This will result in high thermal loads on all plasma facing components of 50-100 kW/m 2 from radiation alone and of up to about 500 kW/m 2 on components additionally exposed to convective loads. In high density scenarios toroidally varying ECRH stray radiation levels of 50-200 kW/m 2 need to be coped with, requiring careful material selection and different shielding and hardening techniques. Furthermore, a gradual buildup of coatings on plasma facing optical components, which without any measures being taken, would lead to high transmission losses already within a few days of long pulse operation (equivalent to about 1 year of operation in pulsed devices like JET or ASDEX-upgrade) and therefore needs to be prevented as much as possible. In addition in situ cleaning as well as absolute calibration techniques need to be developed for all plasma facing optical systems. Here we report about some of our efforts to find, for various types of diagnostics, ways to cope with these adverse effects. Moreover, we give a few examples for individual diagnostic specific issues with respect to quasicontinuous operation, such as the development of a special integrator for the magnetic diagnostics as well as special interferometer types which can cope with unavoidable vibrations and slow path length changes due to, e.g., thermal expansion of the plasma vessel.

  6. Enrichment of target sequences for next-generation sequencing applications in research and diagnostics.

    Science.gov (United States)

    Altmüller, Janine; Budde, Birgit S; Nürnberg, Peter

    2014-02-01

    Abstract Targeted re-sequencing such as gene panel sequencing (GPS) has become very popular in medical genetics, both for research projects and in diagnostic settings. The technical principles of the different enrichment methods have been reviewed several times before; however, new enrichment products are constantly entering the market, and researchers are often puzzled about the requirement to take decisions about long-term commitments, both for the enrichment product and the sequencing technology. This review summarizes important considerations for the experimental design and provides helpful recommendations in choosing the best sequencing strategy for various research projects and diagnostic applications.

  7. A phase angle based diagnostic scheme to planetary gear faults diagnostics under non-stationary operational conditions

    Science.gov (United States)

    Feng, Ke; Wang, Kesheng; Ni, Qing; Zuo, Ming J.; Wei, Dongdong

    2017-11-01

    Planetary gearbox is a critical component for rotating machinery. It is widely used in wind turbines, aerospace and transmission systems in heavy industry. Thus, it is important to monitor planetary gearboxes, especially for fault diagnostics, during its operational conditions. However, in practice, operational conditions of planetary gearbox are often characterized by variations of rotational speeds and loads, which may bring difficulties for fault diagnosis through the measured vibrations. In this paper, phase angle data extracted from measured planetary gearbox vibrations is used for fault detection under non-stationary operational conditions. Together with sample entropy, fault diagnosis on planetary gearbox is implemented. The proposed scheme is explained and demonstrated in both simulation and experimental studies. The scheme proves to be effective and features advantages on fault diagnosis of planetary gearboxes under non-stationary operational conditions.

  8. Software and hardware developments for remote participation in TJ-II operation. Proof of concept using the NPA diagnostic

    International Nuclear Information System (INIS)

    Lopez, A.; Vega, J.; Montoro, A.; Sanchez, E.; Encabo, J.; Portas, A.; Balbin, R.; Fontdecaba, J.M.; Jimenez, J.A.; Dies, J.

    2002-01-01

    The operation protocols for the TJ-II require that all diagnostics be controlled remotely during machine operation. For this reason, most diagnostics have control systems that permit remote actions to be performed on their various subsystems. An Internet browser, which connects to a server where the human machine interfaces (HMIs) for all diagnostics are situated, is used for this. Real time control has been resolved using programmable automates for each diagnostic. Dedicated application software is in operation to provide a user interface for programming digitisers, for signal visualisation and for data processing during TJ-II discharges. This software is an event-based application that can be remotely launched from any X terminal. Other resources provided to users are graphical and computational tools for data analysis, data compression, off-line access to databases, reception of data and its integration in the databases at any moment. Two neutral particle analysers (NPAs) are operating on TJ-II to measure the energy spectra of charge exchange (CX) neutral particles. Protocols require remote control over several actions and subsystems of this diagnostic. With all these tools a proof of the concept of remote participation has being performed during the present experimental campaign. The NPA diagnostic has been operated from UPC-ETSEIB in Barcelona, 600 km of distance from the machine

  9. LOFT advanced control room operator diagnostic and display system (ODDS)

    International Nuclear Information System (INIS)

    Larsen, D.G.; Robb, T.C.

    1980-01-01

    The Loss-of-Fluid Test (LOFT) Reactor Facility in Idaho includes a highly instrumented nuclear reactor operated by the Department of Energy for the purpose of establishing nuclear safety requirements. The results of the development and installation into LOFT of an Operator Diagnostic and Display System (ODDS) are presented. The ODDS is a computer-based graphics display system centered around a PRIME 550 computer with several RAMTEK color graphic display units located within the control room and available to the reactor operators. Use of computer-based color graphics to aid the reactor operator is discussed. A detailed hardware description of the LOFT data system and the ODDS is presented. Methods and problems of backfitting the ODDS equipment into the LOFT plant are discussed

  10. Implementation of the α-CHERS diagnostic for D-T operation of TFTR

    International Nuclear Information System (INIS)

    McKee, G.R.; Fonck, R.J.; Stratton, F.K.

    1995-01-01

    The α-CHERS diagnostic is a high throughput charge exchange recombination spectroscopy diagnostic designed to measure the density profile and time evolution of 0-500 keV alpha particles during D-T operation of TFTR. Following successful tests with a prototype (α-CHERS system, an improved, multi-channel system has been installed for D-T Operation. Three spatial channels may be observed simultaneously, and the spectral resolution of 0.5 nm permits increased alpha energy resolution and improved impurity line identification. More efficient coupling optics between the spectrometer and CCD detectors have increased the light throughput, and radiation shielding has been installed around the detectors and spectrometers to eliminate the neutron/gamma ray noise observed in high power D-D plasmas

  11. Radiolabelled multifunctional nanoparticles for targeted diagnostic and therapeutic applications in oncology

    International Nuclear Information System (INIS)

    Rangger, C.

    2013-01-01

    Nanoparticles, liposomes in particular, have gained great attention as easily engineerable nanoscale systems with distinct properties, offering an ideal platform for a variety of diagnostic and therapeutic applications. The aim of this PhD thesis was the design, synthesis as well as the in vitro and in vivo evaluation of several radiolabelled multifunctional liposomal nanoparticles for the targeted imaging of tumour cells and tumour-induced angiogenesis. Radiolabelling methods for different radionuclides were developed and the liposomes were functionalised with polyethylene glycol (PEG) to improve the pharmacokinetic profile. Targeting sequences such as the tripeptide Arg-Gly-Asp (RGD), the neuropeptide substance P (SP), the somatostatin analogue tyrosine-3-octreotide (TOC), and the vasoactive intestinal peptide (VIP) were tested for their applicability as tools for the targeted delivery of imaging agents. Finally, by the combination of two targeting sequences, namely RGD and SP, on one liposome multireceptor-targeting (hybrid-targeting) was investigated. These multifunctional vehicles were also functionalized with imaging labels for the detection and imaging of tumours by single photon emission computed tomography (SPECT), fluorescence microscopy as well as magnetic resonance (MR) imaging. The liposomes developed in this thesis showed multifunctional properties combining several imaging approaches with specific targeting for oncological applications. In vitro behaviour, e.g., receptor binding could be improved, resulting in optimised targeting shown both by the radiolabel and fluorescent label. However, the in vivo properties, especially the tumour targeting characteristics remained suboptimal, revealing the challenges of targeting approaches in nanoscience. Nonetheless, these results brought important insights for the development and optimisation of multifunctional nanocarriers. (author) [de

  12. On-line diagnostic techniques for air-operated control valves based on time series analysis

    International Nuclear Information System (INIS)

    Ito, Kenji; Matsuoka, Yoshinori; Minamikawa, Shigeru; Komatsu, Yasuki; Satoh, Takeshi.

    1996-01-01

    The objective of this research is to study the feasibility of applying on-line diagnostic techniques based on time series analysis to air-operated control valves - numerous valves of the type which are used in PWR plants. Generally the techniques can detect anomalies by failures in the initial stages for which detection is difficult by conventional surveillance of process parameters measured directly. However, the effectiveness of these techniques depends on the system being diagnosed. The difficulties in applying diagnostic techniques to air-operated control valves seem to come from the reduced sensitivity of their response as compared with hydraulic control systems, as well as the need to identify anomalies in low level signals that fluctuate only slightly but continuously. In this research, simulation tests were performed by setting various kinds of failure modes for a test valve with the same specifications as of a valve actually used in the plants. Actual control signals recorded from an operating plant were then used as input signals for simulation. The results of the tests confirmed the feasibility of applying on-line diagnostic techniques based on time series analysis to air-operated control valves. (author)

  13. Data driven approaches for diagnostics and optimization of NPP operation

    International Nuclear Information System (INIS)

    Pliska, J.; Machat, Z.

    2014-01-01

    The efficiency and heat rate is an important indicator of both the health of the power plant equipment and the quality of power plant operation. To achieve this challenges powerful tool is a statistical data processing of large data sets which are stored in data historians. These large data sets contain useful information about process quality and equipment and sensor health. The paper discusses data-driven approaches for model building of main power plant equipment such as condenser, cooling tower and the overall thermal cycle as well using multivariate regression techniques based on so called a regression triplet - data, model and method. Regression models comprise a base for diagnostics and optimization tasks. Diagnostics and optimization tasks are demonstrated on practical cases - diagnostics of main power plant equipment to early identify equipment fault, and optimization task of cooling circuit by cooling water flow control to achieve for a given boundary conditions the highest power output. (authors)

  14. The Increase of Operational Safety of Ships by Improving Diagnostic Methods for Marine Diesel Engine

    Directory of Open Access Journals (Sweden)

    Kazimierz Witkowski

    2017-06-01

    Full Text Available This article shows the importance of the diagnostic improvement methods of marine engines to boost the economy and safety of operation of marine cargo ships. The need to implement effective diagnostic methods is justified by presenting statistical data of marine diesel engines failure and the cost of their operation. Based on the own research has been proven, for the chosen example, that indicator diagrams and analysis of indicated parameters have limited utility in the diagnosis of damages of marine engine, although this is a method commonly used in operational practice. To achieve greater diagnostic effectiveness, when, based on indicator diagrams, are calculated and then the characteristics of heat release is analyzed - net of heat release characteristics and the intensity of the heat release, it was demonstrated. This procedure is particularly effective in the diagnosis of damage of injection system components marine diesel engine.

  15. Unilateral Opening of Rat Blood-Brain Barrier Assisted by Diagnostic Ultrasound Targeted Microbubbles Destruction.

    Science.gov (United States)

    Xu, Yali; Cui, Hai; Zhu, Qiong; Hua, Xing; Xia, Hongmei; Tan, Kaibin; Gao, Yunhua; Zhao, Jing; Liu, Zheng

    2016-01-01

    Objective. Blood-brain barrier (BBB) is a key obstacle that prevents the medication from blood to the brain. Microbubble-enhanced cavitation by focused ultrasound can open the BBB and proves to be valuable in the brain drug delivery. The study aimed to explore the feasibility, efficacy, and safety of unilateral opening of BBB using diagnostic ultrasound targeted microbubbles destruction in rats. Methods. A transtemporal bone irradiation of diagnostic ultrasound and intravenous injection of lipid-coated microbubbles were performed at unilateral hemisphere. Pathological changes were monitored. Evans Blue extravasation grades, extraction from brain tissue, and fluorescence optical density were quantified. Lanthanum nitrate was traced by transmission electron microscopy. Results. After diagnostic ultrasound mediated microbubbles destruction, Evans Blue extravasation and fluorescence integrated optical density were significantly higher in the irradiated hemisphere than the contralateral side (all p ultrasound-exposed hemisphere (4 ± 1, grade 2) while being invisible in the control side. Lanthanum nitrate tracers leaked through interendothelial cleft and spread to the nerve fiber existed in the irradiation side. Conclusions. Transtemporal bone irradiation under DUS mediated microbubble destruction provides us with a more accessible, safer, and higher selective BBB opening approach in rats, which is advantageous in brain targeted drugs delivery.

  16. Unilateral Opening of Rat Blood-Brain Barrier Assisted by Diagnostic Ultrasound Targeted Microbubbles Destruction

    Directory of Open Access Journals (Sweden)

    Yali Xu

    2016-01-01

    Full Text Available Objective. Blood-brain barrier (BBB is a key obstacle that prevents the medication from blood to the brain. Microbubble-enhanced cavitation by focused ultrasound can open the BBB and proves to be valuable in the brain drug delivery. The study aimed to explore the feasibility, efficacy, and safety of unilateral opening of BBB using diagnostic ultrasound targeted microbubbles destruction in rats. Methods. A transtemporal bone irradiation of diagnostic ultrasound and intravenous injection of lipid-coated microbubbles were performed at unilateral hemisphere. Pathological changes were monitored. Evans Blue extravasation grades, extraction from brain tissue, and fluorescence optical density were quantified. Lanthanum nitrate was traced by transmission electron microscopy. Results. After diagnostic ultrasound mediated microbubbles destruction, Evans Blue extravasation and fluorescence integrated optical density were significantly higher in the irradiated hemisphere than the contralateral side (all p<0.01. Erythrocytes extravasations were demonstrated in the ultrasound-exposed hemisphere (4±1, grade 2 while being invisible in the control side. Lanthanum nitrate tracers leaked through interendothelial cleft and spread to the nerve fiber existed in the irradiation side. Conclusions. Transtemporal bone irradiation under DUS mediated microbubble destruction provides us with a more accessible, safer, and higher selective BBB opening approach in rats, which is advantageous in brain targeted drugs delivery.

  17. Appropriate targeting of artemisinin-based combination therapy by community health workers using malaria rapid diagnostic tests

    DEFF Research Database (Denmark)

    Ndyomugyenyi, Richard; Magnussen, Pascal; Lal, Sham

    2016-01-01

    OBJECTIVE: To compare the impact of malaria rapid diagnostic tests (mRDTs), used by community health workers (CHWs), on the proportion of children ...-randomized trials were conducted in two contrasting areas of moderate-to-high and low malaria transmission in rural Uganda. Each trial examined the effectiveness of mRDTs in the management of malaria and targeting of ACTs by CHWs comparing two diagnostic approaches: (i) presumptive clinical diagnosis of malaria...

  18. Effects-Based Targeting: Application in Operation Desert Storm and Operation Iraqi Freedom

    National Research Council Canada - National Science Library

    Hansbarger, Thomas

    2004-01-01

    .... The United States military must be able to apply effects-based targeting to capitalize on improved capabilities in operational fires and application of national resources against a dynamic, adapting enemy...

  19. Non intrusive check valve diagnostics at Bruce A

    International Nuclear Information System (INIS)

    Marsch, S.P.

    1997-01-01

    Bruce A purchased non intrusive check valve diagnostic equipment in 1995 to ensure operability and availability of critical check valves in the Station. Diagnostics can be used to locate and monitor check valve degradation modes. Bruce A initiated a pilot program targeting check valves with flow through them and ones that completed open or close cycles. Approaches to determine how to confirm operability of passive check valves using non intrusive techniques were explored. A sample population of seventy-three check valves was selected to run the pilot program on prior to complete implementation. The pilot program produced some significant results and some inconclusive results. The program revealed a major finding that check valve performance modeling is required to ensure continuous operability of check valves. (author)

  20. Non intrusive check valve diagnostics at Bruce A

    Energy Technology Data Exchange (ETDEWEB)

    Marsch, S.P. [Ontario Hydro, Bruce Nuclear Generating Station A, Tiverton, ON (Canada)

    1997-07-01

    Bruce A purchased non intrusive check valve diagnostic equipment in 1995 to ensure operability and availability of critical check valves in the Station. Diagnostics can be used to locate and monitor check valve degradation modes. Bruce A initiated a pilot program targeting check valves with flow through them and ones that completed open or close cycles. Approaches to determine how to confirm operability of passive check valves using non intrusive techniques were explored. A sample population of seventy-three check valves was selected to run the pilot program on prior to complete implementation. The pilot program produced some significant results and some inconclusive results. The program revealed a major finding that check valve performance modeling is required to ensure continuous operability of check valves. (author)

  1. High speed photography diagnostics in laser-plasma interaction experiments

    International Nuclear Information System (INIS)

    Andre, M.L.

    1988-01-01

    The authors report on their effort in the development of techniques involved in laser-plasma experiments. This includes not only laser technology but also diagnostics studies and targets design and fabrication. Among the different kind of diagnostics currently used are high speed streak cameras, fast oscilloscopes and detectors sensitive in the i.r., visible, the u.v. region and the x-rays. In this presentation the authors describe the three high power lasers which are still in operation (P 102, OctAL and PHEBUS) and the main diagnostics used to characterize the plasma

  2. Regular pipeline maintenance of gas pipeline using technical operational diagnostics methods

    Energy Technology Data Exchange (ETDEWEB)

    Volentic, J [Gas Transportation Department, Slovensky plynarensky priemysel, Slovak Gas Industry, Bratislava (Slovakia)

    1998-12-31

    Slovensky plynarensky priemysel (SPP) has operated 17 487 km of gas pipelines in 1995. The length of the long-line pipelines reached 5 191 km, distribution network was 12 296 km. The international transit system of long-line gas pipelines ranged 1 939 km of pipelines of various dimensions. The described scale of transport and distribution system represents a multibillion investments stored in the ground, which are exposed to the environmental influences and to pipeline operational stresses. In spite of all technical and maintenance arrangements, which have to be performed upon operating gas pipelines, the gradual ageing takes place anyway, expressed in degradation process both in steel tube, as well as in the anti-corrosion coating. Within a certain time horizon, a consistent and regular application of methods and means of in-service technical diagnostics and rehabilitation of existing pipeline systems make it possible to save substantial investment funds, postponing the need in funds for a complex or partial reconstruction or a new construction of a specific gas section. The purpose of this presentation is to report on the implementation of the programme of in-service technical diagnostics of gas pipelines within the framework of regular maintenance of SPP s.p. Bratislava high pressure gas pipelines. (orig.) 6 refs.

  3. Regular pipeline maintenance of gas pipeline using technical operational diagnostics methods

    Energy Technology Data Exchange (ETDEWEB)

    Volentic, J. [Gas Transportation Department, Slovensky plynarensky priemysel, Slovak Gas Industry, Bratislava (Slovakia)

    1997-12-31

    Slovensky plynarensky priemysel (SPP) has operated 17 487 km of gas pipelines in 1995. The length of the long-line pipelines reached 5 191 km, distribution network was 12 296 km. The international transit system of long-line gas pipelines ranged 1 939 km of pipelines of various dimensions. The described scale of transport and distribution system represents a multibillion investments stored in the ground, which are exposed to the environmental influences and to pipeline operational stresses. In spite of all technical and maintenance arrangements, which have to be performed upon operating gas pipelines, the gradual ageing takes place anyway, expressed in degradation process both in steel tube, as well as in the anti-corrosion coating. Within a certain time horizon, a consistent and regular application of methods and means of in-service technical diagnostics and rehabilitation of existing pipeline systems make it possible to save substantial investment funds, postponing the need in funds for a complex or partial reconstruction or a new construction of a specific gas section. The purpose of this presentation is to report on the implementation of the programme of in-service technical diagnostics of gas pipelines within the framework of regular maintenance of SPP s.p. Bratislava high pressure gas pipelines. (orig.) 6 refs.

  4. MONITORING DIAGNOSTIC INDICATORS DURING OPERATION OF A PRINT MACHIN

    Directory of Open Access Journals (Sweden)

    Jozef Dobránsky

    2015-11-01

    Full Text Available This article deals with monitoring diagnostic indicators during the operation of a machine used for production of packing materials with a print. It analyses low-frequency vibrations measured in individual spherical roller bearings in eight print positions. The rollers in these positions have a different pressure based on positioning these rollers in relation to the central roller. As a result, the article also deals with a correlation of pressure and level of measured low-frequency vibrations. The speed of the print machine (the speed of a line in meters per minute is a very important variable during its operation, this is why it is important to verify the values of vibrations in various speeds of the line, what can lead to revelation of one or more resonance areas. Moreover, it examines vibrations of the central roller drive and measurement of backlash of transmission cogs of this drive. Based on performed analyses recommendations for an operator of the machine have been conceived.

  5. Diagnostics development for steady state operation of the stellarator wendelstein 7-x

    Energy Technology Data Exchange (ETDEWEB)

    Burhenn, R.; Baldzuhn, J.; Dreier, H.; Endler, M.; Jimenez-Gomez, R.; Grosser, K.; Hartfuss, H.J.; Hildebrandt, D.; Hirsch, M.; Koenig, R.; Kornejew, P.; Krychowiak, M.; Laqua, H.P.; Laux, M.; Oosterbeek, J.W.; Pasch, E.; Schneider, W.; Thomsen, H.; Weller, A.; Werner, A.; Wolf, R.; Zhang, D. [Max-Planck-Institute fuer Plasmaphysik, EURATOM Association, D-17491, Greifswald (Germany); Biel, W. [Institut fuer Energieforschung - Plasmaphysik, Forschungszentrum Juelich GmbH, EURATOM Association, Trilateral Euregio Cluster, D-52425 Juelich (Germany)

    2011-03-15

    The gain in experience with long-pulse operation under fusion relevant plasma conditions is an important step towards successful sustainment of future steady state reactor plasmas. The stellarator Wendelstein 7-X (W7-X) [1], presently being under construction, is already equipped with a superconducting coil system and principally capable of quasi-continuous operation. Like other long pulse devices, W7-X is faced with new enhanced technical requirements which have to be met by plasma facing components as well as the diagnostic systems in general. Water-cooled windows were qualified up to 60 kW/m{sup 2} thermal load, and shutters against evaporation of sensitive elements outside the attended time of the diagnostic as well as for baseline control had been developed. Shielding of in-vessel components against damage by absorption of microwave stray radiation originating from the heating systems appears to be one of the most challenging tasks. Experiments using a microwave test chamber identify critical materials and approved the necessity for careful shielding of both, sensitive diagnostics and cables. Spectroscopic systems for monitoring the impurity content and divertor load as well as for robust density measurement are presented (copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  6. Polarized proton Target-III operators manual, revision A

    International Nuclear Information System (INIS)

    Hill, D.; Moretti, A.; Onesto, F.; Rynes, P.

    1976-04-01

    A revision is given of a manual containing standard operating procedures for the vacuum, cryogenic, and electronic systems of a polarized proton target. The discussion includes the target cryostat, the 3 He and 4 He pumping systems, remote monitors and controls, the microwave system, the magnet and power supply, the computerized polarization monitor, the 4 He liquifier and gas recovery system, and miscellaneous auxiliary equipment

  7. Simulation-optimization model of reservoir operation based on target storage curves

    Directory of Open Access Journals (Sweden)

    Hong-bin Fang

    2014-10-01

    Full Text Available This paper proposes a new storage allocation rule based on target storage curves. Joint operating rules are also proposed to solve the operation problems of a multi-reservoir system with joint demands and water transfer-supply projects. The joint operating rules include a water diversion rule to determine the amount of diverted water in a period, a hedging rule based on an aggregated reservoir to determine the total release from the system, and a storage allocation rule to specify the release from each reservoir. A simulation-optimization model was established to optimize the key points of the water diversion curves, the hedging rule curves, and the target storage curves using the improved particle swarm optimization (IPSO algorithm. The multi-reservoir water supply system located in Liaoning Province, China, including a water transfer-supply project, was employed as a case study to verify the effectiveness of the proposed join operating rules and target storage curves. The results indicate that the proposed operating rules are suitable for the complex system. The storage allocation rule based on target storage curves shows an improved performance with regard to system storage distribution.

  8. Prostate Stem Cell Antigen: A Prospective Therapeutic and Diagnostic Target

    Science.gov (United States)

    Raff, Adam B.; Gray, Andrew; Kast, W. Martin

    2009-01-01

    The development of novel clinical tools to combat cancer is an intense field of research and recent efforts have been directed at the identification of proteins that may provide diagnostic, prognostic and/or therapeutic applications due to their restricted expression. To date, a number of protein candidates have emerged as potential clinical tools in the treatment of prostate cancer. Discovered over ten year ago, prostate stem cell antigen (PSCA) is a cell surface antigen that belongs to the Ly-6/Thy-1 family of glycosylphosphatidylinositol-anchored proteins. PSCA is highly overexpressed in human prostate cancer, with limited expression in normal tissues, making it an ideal target for both diagnosis and therapy. Several studies have now clearly correlated the expression of PSCA with relevant clinical benchmarks, such as Gleason score and metastasis, while others have demonstrated the efficacy of PSCA targeting in treatment through various modalities. The purpose of this review is to present the current body of knowledge about PSCA and its potential role in the treatment of human prostate cancer. PMID:18838214

  9. Multiple operating system rotation environment moving target defense

    Science.gov (United States)

    Evans, Nathaniel; Thompson, Michael

    2016-03-22

    Systems and methods for providing a multiple operating system rotation environment ("MORE") moving target defense ("MTD") computing system are described. The MORE-MTD system provides enhanced computer system security through a rotation of multiple operating systems. The MORE-MTD system increases attacker uncertainty, increases the cost of attacking the system, reduces the likelihood of an attacker locating a vulnerability, and reduces the exposure time of any located vulnerability. The MORE-MTD environment is effectuated by rotation of the operating systems at a given interval. The rotating operating systems create a consistently changing attack surface for remote attackers.

  10. The inextricable axis of targeted diagnostic imaging and therapy: An immunological natural history approach

    International Nuclear Information System (INIS)

    Cope, Frederick O.; Abbruzzese, Bonnie; Sanders, James; Metz, Wendy; Sturms, Kristyn; Ralph, David; Blue, Michael; Zhang, Jane; Bracci, Paige; Bshara, Wiam; Behr, Spencer; Maurer, Toby; Williams, Kenneth; Walker, Joshua; Beverly, Allison; Blay, Brooke; Damughatla, Anirudh; Larsen, Mark; Mountain, Courtney; Neylon, Erin

    2016-01-01

    Summary: In considering the challenges of approaches to clinical imaging, we are faced with choices that sometimes are impacted by rather dogmatic notions about what is a better or worse technology to achieve the most useful diagnostic image for the patient. For example, is PET or SPECT most useful in imaging any particular disease dissemination? The dictatorial approach would be to choose PET, all other matters being equal. But is such a totalitarian attitude toward imaging selection still valid? In the face of new receptor targeted SPECT agents one must consider the remarkable specificity and sensitivity of these agents. 99m Tc-Tilmanocept is one of the newest of these agents, now approved for guiding sentinel node biopsy (SLNB) in several solid tumors. Tilmanocept has a K d of 3 × 10 −11 M, and it specificity for the CD206 receptor is unlike any other agent to date. This coupled with a number of facts, that specific disease-associated macrophages express this receptor (100 to 150 thousand receptors), that the receptor has multiple binding sites for tilmanocept (> 2 sites per receptor) and that these receptors are recycled every 15 min to bind more tilmanocept (acting as intracellular “drug compilers” of tilmanocept into non-degraded vesicles), gives serious pause as to how we select our approaches to diagnostic imaging. Clinically, the size of SLNs varies greatly, some, anatomically, below the machine resolution of SPECT. Yet, with tilmanocept targeting, the SLNs are highly visible with macrophages stably accruing adequate 99m Tc-tilmanocept counting statistics, as high target-to-background ratios can compensate for spatial resolution blurring. Importantly, it may be targeted imaging agents per se, again such as tilmanocept, which may significantly shrink any perceived chasm between the imaging technologies and anchor the diagnostic considerations in the targeting and specificity of the agent rather than any lingering dogma about the hardware as the basis

  11. Real time diagnostic for operation at a CW low voltage FEL

    Energy Technology Data Exchange (ETDEWEB)

    Balfour, C.; Shaw, A.; Mayhew, S.E. [and others

    1995-12-31

    At Liverpool University, a system for single user control of an FEL has been designed to satisfy the low voltage FEL (ie 200kV) operational requirements. This system incorporates many aspects of computer automation for beam diagnostics, radiation detection and vacuum system management. In this paper the results of the development of safety critical control systems critical control systems are reported.

  12. Operators and scales: diagnostic and rating issues in psychiatric PET research

    International Nuclear Information System (INIS)

    Aagren, H.

    1992-01-01

    In psychiatric research that for various reasons has to restrict itself to a limited number of subjects, such as studies involving expensive positron emission tomography techniques, issues concerning the parsimonious description of patients gain in importance. The number of descriptive variables must be optimally small. This paper offers a conceptual back-ground for the choice of operators in operational diagnostic systems designed to delimit pathological types, and of rating scales designed to measure syndromal severity in a dimensional way. A practical suggestion in five tenets for the organization of clinical research of this kind is presented. (author)

  13. Operator support and diagnostic reasoning in an industrial process

    Energy Technology Data Exchange (ETDEWEB)

    Aaker, O.

    1996-12-31

    Efficient use of energy in production plants requires that the various processes are well controlled. The main focus of this doctoral thesis is on detection of errors and malfunctions using analytical redundancy and on state estimation using an open loop nonlinear model. A ``residual`` is present if a system does not behave as expected, or if a certain rule is violated. ``Reasoning`` is the action of finding process malfunctions based on observed residuals. The thesis applies a new formalism for comparing diagnostic reasoning methods both in terms of what knowledge is used and how it is used, and suggests a formal model of what is known about the process. The formalism is used to illustrate the difference between diagnostic reasoning based on physically interconnected process units and streams, and reasoning about goals and functions for finding a diagnosis. As an example of application, results and experiences from a test implementation using an open loop model for operator support in a complex fertilizer factory are reported. 108 refs., 61 figs., 37 tabs.

  14. Diagnostics and operative treatment of retrorectal cysts - description of five cases

    International Nuclear Information System (INIS)

    Kolodziejczak, M.; Grochowicz, M.; Kosim, A.; Stefanski, R.; Sudol-Szopinska, I.

    2005-01-01

    Background. Retrorectal cysts (RC) are unusual lesions. Publications on RC are very rare and describe a few cases at most. Methods. Authors describe five patients with RC. The diagnostics of RC was based on the medical history of the patients and the basic diagnostic investigation was trans rectal ultrasonography. An operation to remove the cysts from perineal access was the treatment administered in these cases. Results. In three cases the histopathological examination showed cystis epidermalis. In another case a cyst epithelialized with ciliated epithelium was found. In the last case bone tissue, fatty tissue and fibrous tissue were depicted, all in the state of chronic inflammation. Conclusions. Per rectum digital exam is the basic examination decisive in making the diagnosis. TRUS should be employed as the diagnostic investigation in order to estimate precisely the size of a cyst and its proportion to the rectum wall. Retrorectal cystectomy in perineal access is an effective method of treatment of this disease. This article, likewise other research works, describes a small group of patients, therefore, its conclusions should be treated as preliminary ones. (author)

  15. [Prostate cancer diagnostic by saturation randomized biopsy versus rigid targeted biopsy].

    Science.gov (United States)

    Defontaines, J; Salomon, L; Champy, C; Cholley, I; Chiaradia, M; de la Taille, A

    2017-12-01

    Optimal diagram teaming up randomized biopsy (BR) to targeted biopsy (BC) is still missing for the diagnostic of prostate cancer (CP). This study compares diagram of 6, 12 or 18 BR with or without BC rigid. Between January 2014 and May 2016, 120 patients had prostate biopsy BR and BC. Each patient had 18 BR and BC. Results compared sextant (6 BR), standard (12 BR) and saturation (18 BR) protocol with or without the adding of BC for the detection of CP. Rectal examination was normal, mean PSA at 8.99ng/mL and mean volume at 54cm 3 . It was first round for 48% of patients. Forty-four cancers were found by the group 18 BR+BC (control). The detection rate was respectively, for 6, 12 and 18 BR of 61%, 82% and 91%. The add of BC increased this detection of +27% for 6 BR+BC, +13% for 12 BR+BC and +9% for 18 BR+BC. BC found 70% of all CP. Nine percent of CP were missed by BR only. Significant CP (Gleason≥7) diagnostic was the same for 12 BR+BC and 18 BR+BC. The add of BC to BR increase the detection of CP by 10%. Twelve BR+BC is the optimal diagram for the diagnostic of CP finding 95% of CP and 97% of significant CP. 4. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  16. Preparing diagnostics for long pulse operation at W7-X

    Energy Technology Data Exchange (ETDEWEB)

    Neuner, Ulrich, E-mail: u.neuner@ipp.mpg.de [Max-Planck-Institut fuer Plasmaphysik EURATOM Association, Greifswald (Germany); Brucker, Bertram [Max-Planck-Institut fuer Plasmaphysik EURATOM Association, Greifswald (Germany); Cardella, Antonio [European Commision c/o W7-X, Max-Planck-Institut fuer Plasmaphysik EURATOM Association, Greifswald (Germany); Endler, Michael; Grosser, Klaus; Hathiramani, Dag; Hirsch, Matthias; Koenig, Ralf; Pasch, Ekkehard; Pilopp, Dirk; Schuelke, Matthias; Thiel, Stefan; Thomsen, Henning; Wolf, Robert; Zhang Daihong [Max-Planck-Institut fuer Plasmaphysik EURATOM Association, Greifswald (Germany)

    2012-08-15

    Highlights: Black-Right-Pointing-Pointer In long pulse fusion devices diagnostics are subject to severe heating. Black-Right-Pointing-Pointer Several concepts to reduce the heat influx were applied. Black-Right-Pointing-Pointer Heat conduction was improved to keep the temperature within acceptable limits. - Abstracts: Long pulse operation considerably increases the thermal load on in-vessel components. Diagnostic front-ends formerly employed at short pulse machines therefore have to be considerably re-designed for installation in the stellarator W7-X that is currently being built at Greifswald, Germany. The strategy applied to cope with the thermal load is threefold: to reduce the influx of heat on the component, to conduct the heat inside the component to suitable heat sinks and to choose suitable materials for sensitive components. The first is achieved by the shielding against microwave stray radiation, plasma radiation, thermal radiation and particle fluxes and by absorbing residual microwave stray radiation in the immediate vicinity of sensitive components. The second task, suitable heat conduction, enforces severe restrictions on the use of any thin parts like foils or meshes. Thirdly, in order for a component to survive the residual loads, materials must be chosen that absorb only a small fraction of the microwave stray radiation flux, conduct heat well enough, and survive high temperatures and large temperature gradients. Examples are provided from bolometry, magnetic diagnostics, soft X-ray diagnostics and Thomson scattering. Measurements of microwave stray radiation effects are presented, in particular the effectiveness of several shielding concepts.

  17. The next organizational challenge: finding and addressing diagnostic error.

    Science.gov (United States)

    Graber, Mark L; Trowbridge, Robert; Myers, Jennifer S; Umscheid, Craig A; Strull, William; Kanter, Michael H

    2014-03-01

    Although health care organizations (HCOs) are intensely focused on improving the safety of health care, efforts to date have almost exclusively targeted treatment-related issues. The literature confirms that the approaches HCOs use to identify adverse medical events are not effective in finding diagnostic errors, so the initial challenge is to identify cases of diagnostic error. WHY HEALTH CARE ORGANIZATIONS NEED TO GET INVOLVED: HCOs are preoccupied with many quality- and safety-related operational and clinical issues, including performance measures. The case for paying attention to diagnostic errors, however, is based on the following four points: (1) diagnostic errors are common and harmful, (2) high-quality health care requires high-quality diagnosis, (3) diagnostic errors are costly, and (4) HCOs are well positioned to lead the way in reducing diagnostic error. FINDING DIAGNOSTIC ERRORS: Current approaches to identifying diagnostic errors, such as occurrence screens, incident reports, autopsy, and peer review, were not designed to detect diagnostic issues (or problems of omission in general) and/or rely on voluntary reporting. The realization that the existing tools are inadequate has spurred efforts to identify novel tools that could be used to discover diagnostic errors or breakdowns in the diagnostic process that are associated with errors. New approaches--Maine Medical Center's case-finding of diagnostic errors by facilitating direct reports from physicians and Kaiser Permanente's electronic health record--based reports that detect process breakdowns in the followup of abnormal findings--are described in case studies. By raising awareness and implementing targeted programs that address diagnostic error, HCOs may begin to play an important role in addressing the problem of diagnostic error.

  18. Clustering methods and visualization algorithms to aid nuclear reactor operative diagnostics

    International Nuclear Information System (INIS)

    Pepelyshev, Yu.N.; Dzwinel, W.

    1990-01-01

    The software system developed plays the role of the aid to an operator for nuclear reactor diagnostics. The noise analysis of the reactor parameters such as power, temperature and coolant flow rate constitutes the basis of the system. Combination of data acquisition, data preprocessing, clustering and cluster visualization algorithms with heuristic techniques of results analysis, determine the way of its implementation. Two regimes are available. The first one - extended - is recommended for a long term investigations and the second - suppressed for the aid to the reactor operation monitoring. The system has been tested and developed at the JINR IBR-2 pulsed reactor. 13 refs.; 4 figs.; 2 tabs

  19. Validation and Application of a Custom-Designed Targeted Next-Generation Sequencing Panel for the Diagnostic Mutational Profiling of Solid Tumors.

    Directory of Open Access Journals (Sweden)

    Guy Froyen

    Full Text Available The inevitable switch from standard molecular methods to next-generation sequencing for the molecular profiling of tumors is challenging for most diagnostic laboratories. However, fixed validation criteria for diagnostic accreditation are not in place because of the great variability in methods and aims. Here, we describe the validation of a custom panel of hotspots in 24 genes for the detection of somatic mutations in non-small cell lung carcinoma, colorectal carcinoma and malignant melanoma starting from FFPE sections, using 14, 36 and 5 cases, respectively. The targeted hotspots were selected for their present or future clinical relevance in solid tumor types. The target regions were enriched with the TruSeq approach starting from limited amounts of DNA. Cost effective sequencing of 12 pooled libraries was done using a micro flow cell on the MiSeq and subsequent data analysis with MiSeqReporter and VariantStudio. The entire workflow was diagnostically validated showing a robust performance with maximal sensitivity and specificity using as thresholds a variant allele frequency >5% and a minimal amplicon coverage of 300. We implemented this method through the analysis of 150 routine diagnostic samples and identified clinically relevant mutations in 16 genes including KRAS (32%, TP53 (32%, BRAF (12%, APC (11%, EGFR (8% and NRAS (5%. Importantly, the highest success rate was obtained when using also the low quality DNA samples. In conclusion, we provide a workflow for the validation of targeted NGS by a custom-designed pan-solid tumor panel in a molecular diagnostic lab and demonstrate its robustness in a clinical setting.

  20. Design of the target area for the National Ignition Facility

    International Nuclear Information System (INIS)

    Foley, R.J.; Karpenko, V.P.; Adams, C.H.

    1997-01-01

    The preliminary design of the target area for the National Ignition Facility has been completed. The target area is required to meet a challenging set of engineering system design requirements and user needs. The target area must provide the appropriate conditions before, during, and after each shot. The repeated introduction of large amounts of laser energy into the chamber and subsequent target emissions represent new design challenges for ICF facility design. Prior to each shot, the target area must provide the required target illumination, target chamber vacuum, diagnostics, and optically stable structures. During the shot, the impact of the target emissions on the target chamber, diagnostics, and optical elements is minimized and the workers and public are protected from excessive prompt radiation doses. After the shot, residual radioactivation is managed to allow the required accessibility. Diagnostic data is retrieved, operations and maintenance activities are conducted, and the facility is ready for the next shot. The target area subsystems include the target chamber, target positioner, structural systems, target diagnostics, environmental systems, and the final optics assembly. The engineering design of the major elements of the target area requires a unique combination of precision engineering, structural analysis, opto-mechanical design, random vibration suppression, thermal stability, materials engineering, robotics, and optical cleanliness. The facility has been designed to conduct both x- ray driven targets and to be converted at a later date for direct drive experiments. The NIF has been configured to provide a wide range of experimental environments for the anticipated user groups of the facility. The design status of the major elements of the target area is described

  1. panelcn.MOPS: Copy-number detection in targeted NGS panel data for clinical diagnostics.

    Science.gov (United States)

    Povysil, Gundula; Tzika, Antigoni; Vogt, Julia; Haunschmid, Verena; Messiaen, Ludwine; Zschocke, Johannes; Klambauer, Günter; Hochreiter, Sepp; Wimmer, Katharina

    2017-07-01

    Targeted next-generation-sequencing (NGS) panels have largely replaced Sanger sequencing in clinical diagnostics. They allow for the detection of copy-number variations (CNVs) in addition to single-nucleotide variants and small insertions/deletions. However, existing computational CNV detection methods have shortcomings regarding accuracy, quality control (QC), incidental findings, and user-friendliness. We developed panelcn.MOPS, a novel pipeline for detecting CNVs in targeted NGS panel data. Using data from 180 samples, we compared panelcn.MOPS with five state-of-the-art methods. With panelcn.MOPS leading the field, most methods achieved comparably high accuracy. panelcn.MOPS reliably detected CNVs ranging in size from part of a region of interest (ROI), to whole genes, which may comprise all ROIs investigated in a given sample. The latter is enabled by analyzing reads from all ROIs of the panel, but presenting results exclusively for user-selected genes, thus avoiding incidental findings. Additionally, panelcn.MOPS offers QC criteria not only for samples, but also for individual ROIs within a sample, which increases the confidence in called CNVs. panelcn.MOPS is freely available both as R package and standalone software with graphical user interface that is easy to use for clinical geneticists without any programming experience. panelcn.MOPS combines high sensitivity and specificity with user-friendliness rendering it highly suitable for routine clinical diagnostics. © 2017 The Authors. Human Mutation published by Wiley Periodicals, Inc.

  2. Argus target chamber

    International Nuclear Information System (INIS)

    Rienecker, F. Jr.; Glaros, S.S.; Kobierecki, M.

    1975-01-01

    A target chamber for application in the laser fusion program must satisfy some very basic requirements. (1) Provide a vacuum on the order of 10 -6 torr. (2) Support a microscopically small target in a fixed point in space and verify its location within 5 micrometers. (3) Contain an adjustable beam focusing system capable of delivering a number of laser beams onto the target simultaneously, both in time and space. (4) Provide access for diagnostics to evaluate the results of target irradiation. (5) Have flexibility to allow changes in targets, focusing optics and number of beams. The ARGUS laser which is now under construction at LLL will have a target chamber which meets these requirements in a simple economic manner. The chamber and auxiliary equipment are described, with reference to two double beam focusing systems; namely, lenses and ellipsoidal mirrors. Provision is made for future operation with four beams, using ellipsoidal mirrors for two-sided illumination and lens systems for tetragonal and tetrahedral irradiation

  3. In Depth Diagnostics for RF System Operation in the PEP-II B Factory

    International Nuclear Information System (INIS)

    Van Winkle, Daniel; Fox, John; Teytelman, Dmitry; SLAC

    2005-01-01

    The PEP-II RF systems incorporate numerous feedback loops in the low-level processing for impedance control and operating point regulation. The interaction of the multiple loops with the beam is complicated, and the systems incorporate online diagnostic tools to configure the feedback loops as well as to record fault files in the case of an RF abort. Rapid and consistent analysis of the RF-related beam aborts and other failures is critical to the reliable operation of the B-Factory, especially at the recently achieved high beam currents. Procedures and algorithms used to extract diagnostic information from time domain fault files are presented and illustrated via example interpretations of PEP-II fault file data. Example faults presented will highlight the subtle interpretation required to determine the root cause. Some such examples are: abort kicker firing asynchronously, klystron and cavity arcs, beam loss leading to longitudinal instability, tuner read back jumps and poorly configured low-level RF feedback loop

  4. Development of the HERA-Β-target-control system and study of target operation at the HERA storage ring

    International Nuclear Information System (INIS)

    Issever, S.

    2001-03-01

    The HERA-B experiment investigates the physics of heavy quarks, which are produced in pN reactions of the 920 GeV protons of HERA with the HERA-B internal fixed target. It consists out of eight wires, which surround the proton beam from four sides and is a high luminosity particle source. As being the closest mechanical device to the proton beam, it has to be operated very carefully and thus needs a secure and automatic control system, which additionally must be efficient and reliable to guarantee an efficient HERA-B data taking. The implementation of the target control system and its performance as well as dedicated studies of target-beam physics are presented. These include the measurement of the aperture limitation, usual target operational position, target efficiency, target independent proton loss in HERA and the scrape velocity of the target. The source of rate fluctuations is investigated in detail; among many dependencies environmental noise has a major impact on the rate fluctuations. Further studies include the analysis of beam position fluctuations and its correlation to the rate fluctuations; the rate changes about a factor of 2, if the beam is changing its position by 10 μm. This rate sensitivity is also verified directly by means of step function measurements. Furthermore the step function measurements can be used to study target-beam dynamics on time scales as short as a second. Experiments to reduce the rate sensitivity - the so called beam tail shaping measurements - are presented as well. During target operation a current, which is proportional to the interaction rate, is measured and used to determine the rate of each single wire. It is shown, that the source of this current is delta electron production. Finally the multiwire performance of the target control system is presented. (orig.)

  5. An intelligent diagnostic aid (ida) based upon the simulated and operational experience

    International Nuclear Information System (INIS)

    Zuenkov, M.; Poletykin, A.; Marsiletti, M.

    1999-01-01

    A diagnostic system has been developed addressed to timely trouble shooting in process plants during all operational modes. The theory of this diagnostic system is related with the usage of learning methods for automatic generation of knowledge bases. This approach enables the conversion of 'cause to effect' relations into 'effect to possible causes' ones. As applied to technical diagnosis, this allows one to generate troubleshooting rules of the kind 'symptoms to possible diagnosis' through 'failure to symptoms' relations. The problem of diagnostic rule generation is, thus, reduced to obtaining samples of the symptoms, that is the well known problem of failure modelling. The diagnostic rules are derived from the operation of a simulator according to the following procedure: (a) identification of all initiating events and of the corresponding operational modes; (b) simulation of all the selected transients for a time sufficient to identify the uniqueness of the plant response under each of the initiating event; (c) automatic generation of the set of diagnostic rules that, through the use of temporal logic and a filtering Expert System, associate the evolution of the process parameters and their derivatives to the initial perturbation. The plant model running under the simulator is built-up by means of the LEGO code. The LEGO code is a modular package developed at the Research and Development Department of the Italian National Electricity Board (CRA-ENEL) to facilitate modelling of the dynamics of fossil-fuelled and nuclear power plants. The LEGO code consists of a library of pre-programmed, pre-tested and pre-validated modules, that represent power plant components and a master program which allows the user to build-up a model by automatically interconnecting the modules in the arrangement determined by the modeler. The reference plant is Sampierdarena power station, that is a combined cycle plant dedicated to produce both electrical and heat power. The following

  6. Beam Diagnostics Systems for the National Ignition Facility

    International Nuclear Information System (INIS)

    Demaret, R D; Boyd, R D; Bliss, E S; Gates, A J; Severyn, J R

    2001-01-01

    The National Ignition Facility (NIF) laser focuses 1.8 megajoules of ultraviolet light (wavelength 351 nanometers) from 192 beams into a 600-micrometer-diameter volume. Effective use of this output in target experiments requires that the power output from all of the beams match within 8% over their entire 20-nanosecond waveform. The scope of NIF beam diagnostics systems necessary to accomplish this task is unprecedented for laser facilities. Each beamline contains 110 major optical components distributed over a 510-meter path, and diagnostic tolerances for beam measurement are demanding. Total laser pulse energy is measured with 2.8% precision, and the interbeam temporal variation of pulse power is measured with 4% precision. These measurement goals are achieved through use of approximately 160 sensor packages that measure the energy at five locations and power at three locations along each beamline using 335 photodiodes, 215 calorimeters, and 36 digitizers. Successful operation of such a system requires a high level of automation of the widely distributed sensors. Computer control systems provide the basis for operating the shot diagnostics with repeatable accuracy, assisted by operators who oversee system activities and setup, respond to performance exceptions, and complete calibration and maintenance tasks

  7. Development of a Targeted Next-Generation Sequencing Assay to Detect Diagnostically Relevant Mutations of JAK2, CALR, and MPL in Myeloproliferative Neoplasms.

    Science.gov (United States)

    Frawley, Thomas; O'Brien, Cathal P; Conneally, Eibhlin; Vandenberghe, Elisabeth; Percy, Melanie; Langabeer, Stephen E; Haslam, Karl

    2018-02-01

    The classical Philadelphia chromosome-negative myeloproliferative neoplasms (MPNs), consisting of polycythemia vera, essential thrombocythemia, and primary myelofibrosis, are a heterogeneous group of neoplasms that harbor driver mutations in the JAK2, CALR, and MPL genes. The detection of mutations in these genes has been incorporated into the recent World Health Organization (WHO) diagnostic criteria for MPN. Given a pressing clinical need to screen for mutations in these genes in a routine diagnostic setting, a targeted next-generation sequencing (NGS) assay for the detection of MPN-associated mutations located in JAK2 exon 14, JAK2 exon 12, CALR exon 9, and MPL exon 10 was developed to provide a single platform alternative to reflexive, stepwise diagnostic algorithms. Polymerase chain reaction (PCR) primers were designed to target mutation hotspots in JAK2 exon 14, JAK2 exon 12, MPL exon 10, and CALR exon 9. Multiplexed PCR conditions were optimized by using qualitative PCR followed by NGS. Diagnostic genomic DNA from 35 MPN patients, known to harbor driver mutations in one of the target genes, was used to validate the assay. One hundred percent concordance was observed between the previously-identified mutations and those detected by NGS, with no false positives, nor any known mutations missed (specificity = 100%, CI = 0.96, sensitivity = 100%, CI = 0.89). Improved resolution of mutation sequences was also revealed by NGS analysis. Detection of diagnostically relevant driver mutations of MPN is enhanced by employing a targeted multiplex NGS approach. This assay presents a robust solution to classical MPN mutation screening, providing an alternative to time-consuming sequential analyses.

  8. Experiments on data presentation to process operators in diagnostic tasks

    DEFF Research Database (Denmark)

    Rasmussen, Jens; Goodstein, L. P.

    1972-01-01

    Safety and reliability considerations in modern power plants have prompted our interest in man as an information receiver - especially in diagnostic tasks where the growing complexity of process plants and hence the amount of data involved make it imperative to give the staff proper support....... The great flexibility and capacity of the process computer for data reduction and presentation and for storing information on plant structure and functions give the system designer great freedom in the layout of information display for the staff, but the problem for the designer is how to make proper use...... of this freedom to support the operators efficiently. This is especially important in connection with unique, high-risk, and generally improbable abnormalities in plant functioning. Operator tasks and mental models and the need for matching the encoded information about the plant to these models are treated...

  9. Aptamer-based radiopharmaceuticals for diagnostic imaging and targeted radiotherapy of epithelial tumors

    International Nuclear Information System (INIS)

    Missailidis, Sotiris; Perkins, Alan; Santos-Filho, Sebastiao David; Fonseca, Adenilson de Souza da; Bernardo-Filho, Mario

    2008-01-01

    In the continuous search for earlier diagnosis and improved therapeutic modalities against cancer, based on our constantly increasing knowledge of cancer biology, aptamers hold the promise to expand on current antibody success, but overcoming some of the problems faced with antibodies as therapeutic or delivery agents in cancer. However, as the first aptamer reached the market as an inhibitor against angiogenesis for the treatment of macular degeneration, aptamers have found only limited applications or interest in oncology, and even less as radiopharmaceuticals for diagnostic imaging and targeted radiotherapy of tumours. Yet, the chemistry for the labelling of aptamers and the options to alter their pharmacokinetic properties, to make them suitable for use as radiopharmaceuticals is now available and recent advances in their development can demonstrate that these molecules would make them ideal delivery vehicles for the development of targeted radiopharmaceuticals that could deliver their radiation load with accuracy to the tumour site, offering improved therapeutic properties and reduced side effects. (author)

  10. Aptamer-based radiopharmaceuticals for diagnostic imaging and targeted radiotherapy of epithelial tumors

    Energy Technology Data Exchange (ETDEWEB)

    Missailidis, Sotiris [The Open University, Milton Keynes (United Kingdom). Dept. of Chemistry and Analytical Sciences]. E-mail: s.missailidis@open.ac.uk; Perkins, Alan [University of Nottingham (United Kingdom). Dept. of Medical Physics; Santos-Filho, Sebastiao David; Fonseca, Adenilson de Souza da; Bernardo-Filho, Mario [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Inst. de Biologia Roberto Alcantara Gomes. Dept. de Biofisica e Biometria

    2008-12-15

    In the continuous search for earlier diagnosis and improved therapeutic modalities against cancer, based on our constantly increasing knowledge of cancer biology, aptamers hold the promise to expand on current antibody success, but overcoming some of the problems faced with antibodies as therapeutic or delivery agents in cancer. However, as the first aptamer reached the market as an inhibitor against angiogenesis for the treatment of macular degeneration, aptamers have found only limited applications or interest in oncology, and even less as radiopharmaceuticals for diagnostic imaging and targeted radiotherapy of tumours. Yet, the chemistry for the labelling of aptamers and the options to alter their pharmacokinetic properties, to make them suitable for use as radiopharmaceuticals is now available and recent advances in their development can demonstrate that these molecules would make them ideal delivery vehicles for the development of targeted radiopharmaceuticals that could deliver their radiation load with accuracy to the tumour site, offering improved therapeutic properties and reduced side effects. (author)

  11. PARAMETRIC DIAGNOSTICS OF THE CENTRIFUGAL SUPERCHARGER'S TECHNICAL CONDITION DURING OPERATION

    Directory of Open Access Journals (Sweden)

    Regina A. Khuramshina

    2017-01-01

    Full Text Available Abstract. Objectives The main aim is to develop a mathematical model of a centrifugal compressor and carry out a parametric diagnostics of a centrifugal supercharger's technical condition during operation. Methods  A model is proposed for calculating the thermodynamic properties of natural gas, reducing the parameters of a centrifugal compressor to the initial conditions and to the rotation frequency, as well as the integral indicators of the supercharger's technical state. The technical state of the gas path of the centrifugal supercharger of the compressor unit is determined by the parametric diagnostic method. Results  The software implementation of the mathematical model of centrifugal compressor is carried out using a DVIGwT PC. The analysis of calculations indicates that the model is appropriate, with the error being due to taking into account the properties of iso-butane and i-hexane, in contrast with the VNIIGAZ technique. The evaluation studies of a centrifugal compressor's state are indicative of the presence or absence of its defects. Conclusion  Among a number of the diagnostic methods for evaluating a centrifugal supercharger, the most effective is vibrodiagnostics. However, the search for malfunctions and nascent defects in the flowing part of the centrifugal compressor cannot be limited only to vibrodiagnostic data, which provides about 60% of the reliable information about the state of the gas-air tract. About 20% of the compressor's malfunctions and approximately half of the dangerous modes of the supercharger's flow-through part is detected using thermogasdynamic parametric analysis (parametric diagnostics. The main difficulty of the control over the technical state of the flow-through part of the centrifugal supercharger is in the complication of the quantitative evaluation of the processes taking place in the supercharger, which leads to problems in providing reliable diagnosis during a reasonable period of time.

  12. Operational experiences on the Borssele nuclear power plant using computer based surveillance and diagnostic system on-line

    International Nuclear Information System (INIS)

    Turkcan, E.; Quaadvliet, W.H.J.; Peeters, T.T.J.M.; Verhoef, J.P

    1991-06-01

    The on-line monitoring and diagnostics system of Borssele nuclear power plant (NPP), designed and established by the ECN Energy Research Foundation, has been operating continuously since 1983. The system is extended in form of multiprocessing, multi-tasking structure performing real-time monitoring, on-line reactor parameters' calculation, data-base preparation for expert systems and providing early information on possible malfunctions even in the incipient stage making alert by passive alarms. The system realized has already been operating in the course of 7 fuel cycles of the reactor starting from start-up through normal power operation. An expert system operating on the VAX work station is added to the surveillance and diagnostics system for data base management of the observed physical parameters relevant to the NPP under supervision. The paper highlights the surveillance and diagnostic modules involved, in their actual hierarchical form in use, presents theoretical considerations applied to the design of the surveillance system together with the results obtained through the 12th to 17th fuel cycles of the NPP including start-ups and shut-downs and reveals the experience thus gained by both utility and ECN through the application of the system described. (author). 19 refs.; 4 figs

  13. First set of gated x-ray imaging diagnostics for the Laser Megajoule facility

    Energy Technology Data Exchange (ETDEWEB)

    Rosch, R.; Trosseille, C.; Caillaud, T.; Allouche, V.; Bourgade, J. L.; Briat, M.; Brunel, P.; Burillo, M.; Casner, A.; Depierreux, S.; Gontier, D.; Jadaud, J. P.; Le Breton, J. P.; Llavador, P.; Loupias, B.; Miquel, J. L.; Oudot, G.; Perez, S.; Raimbourg, J.; Rousseau, A. [CEA-DAM Ile de France, Bruyères-le-Châtel, 91297 Arpajon Cedex (France); and others

    2016-03-15

    The Laser Megajoule (LMJ) facility located at CEA/CESTA started to operate in the early 2014 with two quadruplets (20 kJ at 351 nm) focused on target for the first experimental campaign. We present here the first set of gated x-ray imaging (GXI) diagnostics implemented on LMJ since mid-2014. This set consists of two imaging diagnostics with spatial, temporal, and broadband spectral resolution. These diagnostics will give basic measurements, during the entire life of the facility, such as position, structure, and balance of beams, but they will also be used to characterize gas filled target implosion symmetry and timing, to study x-ray radiography and hydrodynamic instabilities. The design requires a vulnerability approach, because components will operate in a harsh environment induced by neutron fluxes, gamma rays, debris, and shrapnel. Grazing incidence x-ray microscopes are fielded as far as possible away from the target to minimize potential damage and signal noise due to these sources. These imaging diagnostics incorporate microscopes with large source-to-optic distance and large size gated microchannel plate detectors. Microscopes include optics with grazing incidence mirrors, pinholes, and refractive lenses. Spatial, temporal, and spectral performances have been measured on x-ray tubes and UV lasers at CEA-DIF and at Physikalisch-Technische Bundesanstalt BESSY II synchrotron prior to be set on LMJ. GXI-1 and GXI-2 designs, metrology, and first experiments on LMJ are presented here.

  14. Modeling companion diagnostics in economic evaluations of targeted oncology therapies: systematic review and methodological checklist.

    Science.gov (United States)

    Doble, Brett; Tan, Marcus; Harris, Anthony; Lorgelly, Paula

    2015-02-01

    The successful use of a targeted therapy is intrinsically linked to the ability of a companion diagnostic to correctly identify patients most likely to benefit from treatment. The aim of this study was to review the characteristics of companion diagnostics that are of importance for inclusion in an economic evaluation. Approaches for including these characteristics in model-based economic evaluations are compared with the intent to describe best practice methods. Five databases and government agency websites were searched to identify model-based economic evaluations comparing a companion diagnostic and subsequent treatment strategy to another alternative treatment strategy with model parameters for the sensitivity and specificity of the companion diagnostic (primary synthesis). Economic evaluations that limited model parameters for the companion diagnostic to only its cost were also identified (secondary synthesis). Quality was assessed using the Quality of Health Economic Studies instrument. 30 studies were included in the review (primary synthesis n = 12; secondary synthesis n = 18). Incremental cost-effectiveness ratios may be lower when the only parameter for the companion diagnostic included in a model is the cost of testing. Incorporating the test's accuracy in addition to its cost may be a more appropriate methodological approach. Altering the prevalence of the genetic biomarker, specific population tested, type of test, test accuracy and timing/sequence of multiple tests can all impact overall model results. The impact of altering a test's threshold for positivity is unknown as it was not addressed in any of the included studies. Additional quality criteria as outlined in our methodological checklist should be considered due to the shortcomings of standard quality assessment tools in differentiating studies that incorporate important test-related characteristics and those that do not. There is a need to refine methods for incorporating the characteristics

  15. Description, operation, and diagnostic routines for the adaptive intrusion data system

    International Nuclear Information System (INIS)

    Corlis, N.E.; Johnson, C.S.

    1978-03-01

    An Adaptive Intrusion Data System (AIDS) was developed to collect data from intrusion alarm sensors as part of an evaluation system to improve sensor performance. AIDS is a unique digital data compression, storage, and formatting system. It also incorporates a capability for video selection and recording for assessment of the sensors monitored by the system. The system is software reprogrammable to numerous configurations that may be utilized for the collection of environmental, bi-metal, analog, and video data. This manual covers the procedures for operating AIDS. Instructions are given to guide the operator in software programming and control option selections required to program AIDS for data collection. Software diagnostic programs are included in this manual as a method of isolating system problems

  16. Simulated performance of the optical Thomson scattering diagnostic designed for the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Ross, J. S., E-mail: ross36@llnl.gov; Datte, P.; Divol, L.; Galbraith, J.; Hatch, B.; Landen, O.; Manuel, A. M.; Molander, W.; Moody, J. D.; Swadling, G. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Froula, D. H.; Katz, J. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623 (United States); Glenzer, S. H. [SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Kilkenny, J. [General Atomics, San Diego, California 92186 (United States); Montgomery, D. S. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Weaver, J. [Plasma Physics Division, Naval Research Laboratory, Washington, DC 20375 (United States)

    2016-11-15

    An optical Thomson scattering diagnostic has been designed for the National Ignition Facility to characterize under-dense plasmas. We report on the design of the system and the expected performance for different target configurations. The diagnostic is designed to spatially and temporally resolve the Thomson scattered light from laser driven targets. The diagnostic will collect scattered light from a 50 × 50 × 200 μm volume. The optical design allows operation with different probe laser wavelengths. A deep-UV probe beam (λ{sub 0} = 210 nm) will be used to Thomson scatter from electron plasma densities of ∼5 × 10{sup 20} cm{sup −3} while a 3ω probe will be used for plasma densities of ∼1 × 10{sup 19} cm{sup −3}. The diagnostic package contains two spectrometers: the first to resolve Thomson scattering from ion acoustic wave fluctuations and the second to resolve scattering from electron plasma wave fluctuations. Expected signal levels relative to background will be presented for typical target configurations (hohlraums and a planar foil).

  17. Surveillance and diagnostics in NPPs - progress made, operational needs, and perspective for future developments

    International Nuclear Information System (INIS)

    Wach, D.

    1996-01-01

    After a brief description of the broad and comprehensive knowledge base in incipient failure detection and on-line diagnostics at Institut fuer Sicherheitstechnologie ISTec, the international situation is reflected, and the operational needs as known from all the regular services of ISTec are discussed. ISTec has been involved in signal analyses, diagnosis support, and surveillance services. Long-term trending of signatures and features are performed, signature data banks with reference and fault-effected signatures were built up, a diagnosis center with advanced support tools has been established. The emphasis is placed on the development necessary in future to cope with the operator's interests. Most of the recent R and D work, aimed at the implementation of new information processing tools and techniques, will need time to be accepted in practice (long-term perspectives). Therefore, the actions and developments described under short-term perspectives should be pushed in order to progress in on-line NPP early failure diagnostics. (author)

  18. Clinical target volume delineation in glioblastomas: pre-operative versus post-operative/pre-radiotherapy MRI

    Science.gov (United States)

    Farace, P; Giri, M G; Meliadò, G; Amelio, D; Widesott, L; Ricciardi, G K; Dall'Oglio, S; Rizzotti, A; Sbarbati, A; Beltramello, A; Maluta, S; Amichetti, M

    2011-01-01

    Objectives Delineation of clinical target volume (CTV) is still controversial in glioblastomas. In order to assess the differences in volume and shape of the radiotherapy target, the use of pre-operative vs post-operative/pre-radiotherapy T1 and T2 weighted MRI was compared. Methods 4 CTVs were delineated in 24 patients pre-operatively and post-operatively using T1 contrast-enhanced (T1PRECTV and T1POSTCTV) and T2 weighted images (T2PRECTV and T2POSTCTV). Pre-operative MRI examinations were performed the day before surgery, whereas post-operative examinations were acquired 1 month after surgery and before chemoradiation. A concordance index (CI) was defined as the ratio between the overlapping and composite volumes. Results The volumes of T1PRECTV and T1POSTCTV were not statistically different (248 ± 88 vs 254 ± 101), although volume differences >100 cm3 were observed in 6 out of 24 patients. A marked increase due to tumour progression was shown in three patients. Three patients showed a decrease because of a reduced mass effect. A significant reduction occurred between pre-operative and post-operative T2 volumes (139 ± 68 vs 78 ± 59). Lack of concordance was observed between T1PRECTV and T1POSTCTV (CI = 0.67 ± 0.09), T2PRECTV and T2POSTCTV (CI = 0.39 ± 0.20) and comparing the portion of the T1PRECTV and T1POSTCTV not covered by that defined on T2PRECTV images (CI = 0.45 ± 0.16 and 0.44 ± 0.17, respectively). Conclusion Using T2 MRI, huge variations can be observed in peritumoural oedema, which are probably due to steroid treatment. Using T1 MRI, brain shifts after surgery and possible progressive enhancing lesions produce substantial differences in CTVs. Our data support the use of post-operative/pre-radiotherapy T1 weighted MRI for planning purposes. PMID:21045069

  19. Optical diagnostics of mercury jet for an intense proton target.

    Science.gov (United States)

    Park, H; Tsang, T; Kirk, H G; Ladeinde, F; Graves, V B; Spampinato, P T; Carroll, A J; Titus, P H; McDonald, K T

    2008-04-01

    An optical diagnostic system is designed and constructed for imaging a free mercury jet interacting with a high intensity proton beam in a pulsed high-field solenoid magnet. The optical imaging system employs a backilluminated, laser shadow photography technique. Object illumination and image capture are transmitted through radiation-hard multimode optical fibers and flexible coherent imaging fibers. A retroreflected illumination design allows the entire passive imaging system to fit inside the bore of the solenoid magnet. A sequence of synchronized short laser light pulses are used to freeze the transient events, and the images are recorded by several high speed charge coupled devices. Quantitative and qualitative data analysis using image processing based on probability approach is described. The characteristics of free mercury jet as a high power target for beam-jet interaction at various levels of the magnetic induction field is reported in this paper.

  20. Assessment of diagnostic methods for determining degradation of motor-operated valves

    International Nuclear Information System (INIS)

    Haynes, H.D.; Farmer, W.S.

    1992-01-01

    The Oak Ridge National Laboratory (ORNL) has carried out a comprehensive aging assessment of motor-operated valves (MOVs) in support of the Nuclear Plant Aging Research (NPAR) program. This paper provides a summary of the ORNL MOV aging assessment with emphasis on the identification, evaluation, and application of MOV monitoring methods and techniques. The diagnostic information available from any MOV measurable parameters was evaluated by ORNL using MOVs that were mounted on test stands. Those tests led to the conclusion that the single most informative MOV measurable parameter was also the one which was most easily acquired, namely the motor current. Motor current signature analysis (MCSA) was found to provide detailed information related to the condition of the motor, motor operator, and valve across a wide range of levels. As part of the MOV aging assessment, several tests were carried out by ORNL on MOVs having implanted defects and degradations. Tests were also performed on many MOVs located within a nuclear power plant. In addition, ORNL participated in the Gate Valve Flow Interruption Blowdown Test program carried out at Wyle Laboratories in Huntsville, Alabama. Results from all of these tests are summarized in this paper and several selected examples are given. Other areas covered in this paper include descriptions of relevant regulatory issues and activities, other related diagnostics research at ORNL, and interactions ORNL has had with outside organizations for the purpose of disseminating research results

  1. Numerical investigations of the WASA pellet target operation and proposal of a new technique for the PANDA pellet target

    International Nuclear Information System (INIS)

    Varentsov, Victor L.

    2011-01-01

    The conventional nozzle vibration technique of the hydrogen micro-droplet generation that is supposed to be used for internal pellet target production for the future PANDA experiment at the international FAIR facility in Darmstadtfor is described. The operation of this technique has been investigated by means of detailed computer simulations. Results of calculations for the geometry and operation conditions of the WASA pellet generator are presented and discussed. We have found that for every given pellet size, there is a set of operation parameters where the efficiency of the WASA hydrogen pellet target operation is considerably increased. Moreover, the results of presented computer simulations clearly show that the future PANDA pellet target setup can be realized with the use of much smaller (and cheaper) vacuum pumps than those used at present in the WASA hydrogen pellet target. To qualitatively improve the PANDA hydrogen pellet target performance we have proposed the use of a novel flow focusing method of Ganan-Calvo and Barreto (1997,1999) combined with the use of conventional vacuum injection capillary. Possibilities of this approach for the PANDA pellet target production have been also explored by means of computer simulations. The results of these simulations show that the use of this new approach looks very promising and in particular, there is no need here to use of expensive ultra-pure hydrogen to prevent nozzle clogging or freezing up due to impurities and it will allow simple, fast, smooth and a wide range of change of pellet sizes in accordance with requirements of different experiments at the PANDA detector. In this article we also propose and describe the idea of a new technique to break up a liquid microjet into microdroplets using a process of liquid jet evaporation under pulsed laser beam irradiation. This technique should be experimentally checked before it may be used in the design of the future PANDA pellet target setup.

  2. Numerical investigations of the WASA pellet target operation and proposal of a new technique for the PANDA pellet target

    Energy Technology Data Exchange (ETDEWEB)

    Varentsov, Victor L., E-mail: v.varentsov@gsi.de [Institute for Theoretical and Experimental Physics, B. Cheremushkinskaya 25, 117218 Moscow (Russian Federation)

    2011-08-01

    The conventional nozzle vibration technique of the hydrogen micro-droplet generation that is supposed to be used for internal pellet target production for the future PANDA experiment at the international FAIR facility in Darmstadtfor is described. The operation of this technique has been investigated by means of detailed computer simulations. Results of calculations for the geometry and operation conditions of the WASA pellet generator are presented and discussed. We have found that for every given pellet size, there is a set of operation parameters where the efficiency of the WASA hydrogen pellet target operation is considerably increased. Moreover, the results of presented computer simulations clearly show that the future PANDA pellet target setup can be realized with the use of much smaller (and cheaper) vacuum pumps than those used at present in the WASA hydrogen pellet target. To qualitatively improve the PANDA hydrogen pellet target performance we have proposed the use of a novel flow focusing method of Ganan-Calvo and Barreto (1997,1999) combined with the use of conventional vacuum injection capillary. Possibilities of this approach for the PANDA pellet target production have been also explored by means of computer simulations. The results of these simulations show that the use of this new approach looks very promising and in particular, there is no need here to use of expensive ultra-pure hydrogen to prevent nozzle clogging or freezing up due to impurities and it will allow simple, fast, smooth and a wide range of change of pellet sizes in accordance with requirements of different experiments at the PANDA detector. In this article we also propose and describe the idea of a new technique to break up a liquid microjet into microdroplets using a process of liquid jet evaporation under pulsed laser beam irradiation. This technique should be experimentally checked before it may be used in the design of the future PANDA pellet target setup.

  3. NIF diagnostic damage and design issues

    International Nuclear Information System (INIS)

    Landen, N.

    1999-01-01

    The NIF target environment is evaluated with respect to target and diagnostic debris and with respect to instrument survivability in the presence of target debris and radiation. Quantitative estimates are arrived at by extrapolating from Nova and Omega experience using simple scaling arguments. Specifically, we evaluate the closest distance of approach of various components of DIM-based diagnostics such as target mounted pinhole arrays, open detectors, filters, x-ray optics, and spectrometers. We also include constraints on achieving adequate signal-to-noise on x-ray diagnostics. Four of the most important conclusions are as follows: (1) The required full NIF stand-off distance for heavily filtered detectors (e.g. multi-keV x-ray and particle detectors) as determined by concerns of diagnostic debris and diagnostic survivability to debris and radiation is no more than 100 cm. (2) Target mounted pinhole arrays and slits mounted a few cm from chamber center at NIF will survive long enough to record data and should be an acceptable source of shrapnel debris. (3) DIM-based instrument stand-off distances are compatible with achieving the same photon statistics (or better with ongoing improvements in detector resolution and noise) than available with current Nova and Omega SIM- or TIM-based instrumentation. Section II reviews target and diagnostic debris with respect to final optics. Section III reviews debris and radiation with respect to all diagnostic components. The following laser scaling between Nova/Omega and NIF is used throughout unless otherwise specified: laser energy E = 100x, drive duration τ = 6x and hence for a given laser intensity or hohlraum temperature, target size r approximately √(E/τ) = 4x. The 100x increase in E accounts for the fact that many Nova shots were performed with only 20 kJ and all LLNL Omega shots were performed with only 15 kJ

  4. RTNS-II [Rotating Target Neutron Source II] operational summary

    International Nuclear Information System (INIS)

    Heikkinen, D.W.

    1988-09-01

    The Rotating Target Neutron Source II facility (RTNS-II) operated for over nine years. Its purpose was to provide high intensities of 14 MeV neutrons for materials studies in the fusion energy program. For the period from 1982-1987, the facility was supported by both the US (Department of Energy) and Japan (Ministry of Education, Culture, and Science). RTNS-II contains two accelerator-based neutron sources which use the T(d,n) 4 He reaction. In this paper, we will summarize the operational history of RTNS-II. Typical operating parameters are given. In addition, a brief description of the experimental program is presented. The current status and future options for the facility are discussed. 7 refs., 5 tabs

  5. A distributed computational search strategy for the identification of diagnostics targets: Application to finding aptamer targets for methicillin-resistant staphylococci

    Directory of Open Access Journals (Sweden)

    Flanagan Keith

    2014-06-01

    Full Text Available The rapid and cost-effective identification of bacterial species is crucial, especially for clinical diagnosis and treatment. Peptide aptamers have been shown to be valuable for use as a component of novel, direct detection methods. These small peptides have a number of advantages over antibodies, including greater specificity and longer shelf life. These properties facilitate their use as the detector components of biosensor devices. However, the identification of suitable aptamer targets for particular groups of organisms is challenging. We present a semi-automated processing pipeline for the identification of candidate aptamer targets from whole bacterial genome sequences. The pipeline can be configured to search for protein sequence fragments that uniquely identify a set of strains of interest. The system is also capable of identifying additional organisms that may be of interest due to their possession of protein fragments in common with the initial set. Through the use of Cloud computing technology and distributed databases, our system is capable of scaling with the rapidly growing genome repositories, and consequently of keeping the resulting data sets up-to-date. The system described is also more generically applicable to the discovery of specific targets for other diagnostic approaches such as DNA probes, PCR primers and antibodies.

  6. A distributed computational search strategy for the identification of diagnostics targets: application to finding aptamer targets for methicillin-resistant staphylococci.

    Science.gov (United States)

    Flanagan, Keith; Cockell, Simon; Harwood, Colin; Hallinan, Jennifer; Nakjang, Sirintra; Lawry, Beth; Wipat, Anil

    2014-06-30

    The rapid and cost-effective identification of bacterial species is crucial, especially for clinical diagnosis and treatment. Peptide aptamers have been shown to be valuable for use as a component of novel, direct detection methods. These small peptides have a number of advantages over antibodies, including greater specificity and longer shelf life. These properties facilitate their use as the detector components of biosensor devices. However, the identification of suitable aptamer targets for particular groups of organisms is challenging. We present a semi-automated processing pipeline for the identification of candidate aptamer targets from whole bacterial genome sequences. The pipeline can be configured to search for protein sequence fragments that uniquely identify a set of strains of interest. The system is also capable of identifying additional organisms that may be of interest due to their possession of protein fragments in common with the initial set. Through the use of Cloud computing technology and distributed databases, our system is capable of scaling with the rapidly growing genome repositories, and consequently of keeping the resulting data sets up-to-date. The system described is also more generically applicable to the discovery of specific targets for other diagnostic approaches such as DNA probes, PCR primers and antibodies.

  7. Opportunities and challenges for photon diagnostics at the soft X-ray FEL FLASH in simultaneous operation mode (Conference Presentation)

    Science.gov (United States)

    Kuhlmann, Marion; Treusch, Rolf; Plönjes-Palm, Elke; Faatz, Bart; Tiedtke, Kai; Braune, Markus; Keitel, Barbara

    2017-06-01

    FLASH operates two distinguished undulator sections driven by one linear accelerator. In the 11th year of user operation the grown demands for detailed photon beam performances are doubled approached. The more complex machine settings and setup times require a more and more efficient determination of its characteristics concerning electron- and photon-beams. The photon diagnostics systems, e.g. gas monitor detection, photon-ion spectroscopy, or diffractive tools, not only have to deal on a regular basis with fundamental wavelengths between 4nm and 90nm, also they have to be reliable from 1µJ up to 1mJ of average single pulse energy. For the success of the experiments the error bars of many diagnostics measurements need to be pushed into their current limits and developments to go further are always issued. Especial, the pulse duration in conjunction with the spectral width has been accessed in the last year. Direct approaches of fundamental wavelengths below the Nitrogene K-edge and higher harmonics in and below the water window were achieved. While in principal distinguished to each other, the photon diagnostics tools of FLASH1 and FLASH2 add-up to a more complete understanding of the other. Together they allow for a better perspective towards further developments and a more suitable use of beam times. The intermingled knowledge of electron- and photon-beams is essential for an FEL particular in simultaneous operation mode. Examples out of regular user operation and distinguished FEL-studies are given to illustrate the current state of the photon diagnostics at FLASH.

  8. Study on diagnostic plant analyzer method for support of emergency operation

    International Nuclear Information System (INIS)

    Yoshikawa, H.; Gofuku, A.; Itoh, K.; Wakabayashi, J.

    1986-01-01

    Methods of time-critical diagnostic plant analyzer are investigated which would serve as support to emergency operation of nuclear power plant. A faster-than-real-time simulator code TOKRAC is developed for analyzing PWR primary loop thermo-hydraulics of small-break LOCA and it is applied for a numerical experiment of initial phase of TMI-2 accident. TOKRAC resulted in a good agreement with a RELAP4/MOD6 calculation and the plant record with as fast as can one-tenth of real time. A real-time estimator of SG heat transfer rate based on Kalman filter is proposed and its applicability is verified using LOFT ATWS experimental data. With regards to how to integrate those methods into the software system in operation support center, a new concept of module-based simulation system is proposed which aims at offering a flexible and human-cognitive oriented environment for various analytical tool development

  9. Generic study on the design and operation of high power targets

    Directory of Open Access Journals (Sweden)

    A. Ahmad

    2014-02-01

    Full Text Available With the move towards beam power in the range of 1–10 MW, a thorough understanding of the response of target materials and auxiliary systems to high power densities and intense radiation fields is required. This paper provides insight into three major aspects related to the design and operation of high power solid targets: thermal stresses, coolant performance, and radiation damage. Where appropriate, a figure-of-merit approach is followed to facilitate the comparison between different target or coolant candidates. The section on radiation damage reports total and spatial variations of displacement-per-atom and helium production levels in different target materials.

  10. Target Product Profile for a Diagnostic Assay to Differentiate between Bacterial and Non-Bacterial Infections and Reduce Antimicrobial Overuse in Resource-Limited Settings: An Expert Consensus.

    Directory of Open Access Journals (Sweden)

    Sabine Dittrich

    Full Text Available Acute fever is one of the most common presenting symptoms globally. In order to reduce the empiric use of antimicrobial drugs and improve outcomes, it is essential to improve diagnostic capabilities. In the absence of microbiology facilities in low-income settings, an assay to distinguish bacterial from non-bacterial causes would be a critical first step. To ensure that patient and market needs are met, the requirements of such a test should be specified in a target product profile (TPP. To identify minimal/optimal characteristics for a bacterial vs. non-bacterial fever test, experts from academia and international organizations with expertise in infectious diseases, diagnostic test development, laboratory medicine, global health, and health economics were convened. Proposed TPPs were reviewed by this working group, and consensus characteristics were defined. The working group defined non-severely ill, non-malaria infected children as the target population for the desired assay. To provide access to the most patients, the test should be deployable to community health centers and informal health settings, and staff should require 90% and >80% for sensitivity and specificity, respectively. Other key characteristics, to account for the challenging environment at which the test is targeted, included: i time-to-result <10 min (but maximally <2 hrs; ii storage conditions at 0-40°C, ≤90% non-condensing humidity with a minimal shelf life of 12 months; iii operational conditions of 5-40°C, ≤90% non-condensing humidity; and iv minimal sample collection needs (50-100μL, capillary blood. This expert approach to define assay requirements for a bacterial vs. non-bacterial assay should guide product development, and enable targeted and timely efforts by industry partners and academic institutions.

  11. Development of an integrated condition monitoring and diagnostic system for motor-operated valves used in nuclear power plant

    International Nuclear Information System (INIS)

    Carneiro, Alvaro Luiz Guimaraes

    2003-01-01

    The reliability question of the components, specifically of motor operated valves, became one of the most important issues to be investigated in nuclear power plants, considering security and life plant extension. Therefore, the necessity of improvements in monitoring and diagnosis methods started to be of extreme relevance in the maintenance predictive field, establishing as main goal the reliability and readiness of the system components. Specially in nuclear power plants, the predictive maintenance contributes in the security factor in order to diagnosis in advance the occurrence of a possible failure, preventing severe situations. It also presents a contribution on the economic side by establishing a better maintenance programming, and reducing unexpected shutdown. The development of non intrusive monitoring and diagnostic method makes it possible to identify malfunctions in plant components during normal plant operation. This dissertation presents the development of an integrated condition monitoring system for motor-operated valves used in nuclear power plants. The methodology used in this project is based on the electric motor power signatures analysis, during the closing and opening stroke time of the valve. Once the measurements baseline diagnostic of the motor-operated valve is taken, it is possible to detect long-term deviations during valve lifetime, detecting in advance valve failures. The system implements two parallel techniques for detection and categorization of anomalies: expert system using fuzzy logic based on rules and knowledge base, providing a systematic approach for decision making, and the Wavelet Transform Technique, where the main goal is to obtain more detailed information contained in the measured data, identifying and characterizing the transients phenomena in the time and frequency domains, correlating them to failures situations in the incipient stage. The conditioning monitoring and diagnostic system was designed and implemented at

  12. Nova target experiments

    International Nuclear Information System (INIS)

    Drake, R.P.

    1985-11-01

    The Nova laser, at the Lawrence Livermore National Laboratory, provides unique opportunities for target experiments. It has unprecedented energy on target and significant flexibility. The paper presented by John Hunt described the capabilities and the status of Nova. This paper discusses plans for future experiments using Nova, and the present status of target experiments. We plan to perform high-quality physics experiments that exploit the unique capabilities of Nova. Because this is our goal, we are fielding an extensive array of well-characterized target diagnostics to measure the emissions from the target. The first section of this paper discusses the basic target diagnostics. We are also taking care to quantify the performance of the laser

  13. The Development of a Framework for Target Diagnostic Centralized Control System (TDCCS) in ICF Experiments

    International Nuclear Information System (INIS)

    Zhang Chi; Wang Jian; Yu Xiaoqi; Yang Dong

    2008-01-01

    A framework for target diagnostic centralized control system (TDCCS) in inertial confinement fusion (ICF) experiment has been developed. The developed framework is based on the common object request broker architecture (CORBA) standard and part of the concept from the ICFRoot (a framework based on ROOT for ICF experiments) framework design. This framework is of a component architecture, including a message bus, command executer, status processor, parser and proxy. To test the function of the framework, a simplified prototype of the TDCCS has been developed as well.

  14. Evaluation of Fibroblast Activation Protein-Alpha (FAP) as a Diagnostic Marker and Therapeutic Target in Prostate Cancer

    Science.gov (United States)

    2009-12-01

    low molecular weight recombinant human gelatin: development of a substitute for animal- derived gelatin with superior features, Protein Expr. Purif...by the honey - bee , could be modified to a form that was no longer hydro- lyzed by the native activator protease DPP4 but, instead, was hydrolyzed by...TITLE: Evaluation of Fibroblast Activation Protein -Alpha (FAP) as a Diagnostic Marker and Therapeutic Target in Prostate Cancer PRINCIPAL

  15. Diagnostic and therapeutic peroral cholangioscopy

    Directory of Open Access Journals (Sweden)

    Jong Ho Moon

    2012-01-01

    Full Text Available Peroral cholangioscopy (POC provides direct visualization of the bile duct and facilitates diagnostic or therapeutic intervention. The currently available single-operator POC systems are "Mother-baby" scope system, SpyGlass direct visualization system, and direct POC using a regular ultra-slim upper endoscope. Direct POC using an ultra-slim upper endoscope having a larger 2-mm working channel can provide a valuable and economic solution for evaluating bile-duct lesions. Main diagnostic procedures under direct POC are visual characterization and optically guided target biopsy for the indeterminate bile duct lesion. Image-enhanced endoscopy such as narrow-band imaging has shown promise for more detailed evaluation of mucosal abnormality and can be performed under direct POC. Intracorporeal lithotripsy such as electrohydraulic lithotripsy or laser lithotripsy is a main therapeutic intervention of direct POC for patients with bile duct stones that are resistant to conventional endoscopic stone-removal procedures. Besides, tumor ablation therapy, such as photodynamic therapy and argon plasma coagulation may be also performed using direct POC. Further developments of the endoscope and specialized accessories or devices are expected to facilitate diagnostic and therapeutic role of this cholangioscopic procedure.

  16. Overview of diagnostic performance and results for the first operation phase in Wendelstein 7-X (invited).

    Science.gov (United States)

    Krychowiak, M; Adnan, A; Alonso, A; Andreeva, T; Baldzuhn, J; Barbui, T; Beurskens, M; Biel, W; Biedermann, C; Blackwell, B D; Bosch, H S; Bozhenkov, S; Brakel, R; Bräuer, T; Brotas de Carvalho, B; Burhenn, R; Buttenschön, B; Cappa, A; Cseh, G; Czarnecka, A; Dinklage, A; Drews, P; Dzikowicka, A; Effenberg, F; Endler, M; Erckmann, V; Estrada, T; Ford, O; Fornal, T; Frerichs, H; Fuchert, G; Geiger, J; Grulke, O; Harris, J H; Hartfuß, H J; Hartmann, D; Hathiramani, D; Hirsch, M; Höfel, U; Jabłoński, S; Jakubowski, M W; Kaczmarczyk, J; Klinger, T; Klose, S; Knauer, J; Kocsis, G; König, R; Kornejew, P; Krämer-Flecken, A; Krawczyk, N; Kremeyer, T; Książek, I; Kubkowska, M; Langenberg, A; Laqua, H P; Laux, M; Lazerson, S; Liang, Y; Liu, S C; Lorenz, A; Marchuk, A O; Marsen, S; Moncada, V; Naujoks, D; Neilson, H; Neubauer, O; Neuner, U; Niemann, H; Oosterbeek, J W; Otte, M; Pablant, N; Pasch, E; Sunn Pedersen, T; Pisano, F; Rahbarnia, K; Ryć, L; Schmitz, O; Schmuck, S; Schneider, W; Schröder, T; Schuhmacher, H; Schweer, B; Standley, B; Stange, T; Stephey, L; Svensson, J; Szabolics, T; Szepesi, T; Thomsen, H; Travere, J-M; Trimino Mora, H; Tsuchiya, H; Weir, G M; Wenzel, U; Werner, A; Wiegel, B; Windisch, T; Wolf, R; Wurden, G A; Zhang, D; Zimbal, A; Zoletnik, S

    2016-11-01

    Wendelstein 7-X, a superconducting optimized stellarator built in Greifswald/Germany, started its first plasmas with the last closed flux surface (LCFS) defined by 5 uncooled graphite limiters in December 2015. At the end of the 10 weeks long experimental campaign (OP1.1) more than 20 independent diagnostic systems were in operation, allowing detailed studies of many interesting plasma phenomena. For example, fast neutral gas manometers supported by video cameras (including one fast-frame camera with frame rates of tens of kHz) as well as visible cameras with different interference filters, with field of views covering all ten half-modules of the stellarator, discovered a MARFE-like radiation zone on the inboard side of machine module 4. This structure is presumably triggered by an inadvertent plasma-wall interaction in module 4 resulting in a high impurity influx that terminates some discharges by radiation cooling. The main plasma parameters achieved in OP1.1 exceeded predicted values in discharges of a length reaching 6 s. Although OP1.1 is characterized by short pulses, many of the diagnostics are already designed for quasi-steady state operation of 30 min discharges heated at 10 MW of ECRH. An overview of diagnostic performance for OP1.1 is given, including some highlights from the physics campaigns.

  17. ICF in the U.S.: Facilities and diagnostics

    International Nuclear Information System (INIS)

    Coleman, L.W.

    1988-08-01

    In the last few years there has been significant progress in ICF research in laboratories in the United States and elsewhere. These advances have occurred in areas that range from demonstrating an innovative laser beam smoothing techniques important for both directly and indirectly driven ICF, to achieving a more complete understanding of capsule implosions and related physics. This progress has been possible because of the capabilities provided by the ICF laser-target facilities currently in operation and the new developments in diagnostics, particularly for measurements of the implosion process and the conditions in the compressed capsule core. Both of these topics, facilities and selected new diagnostics capabilities in the US ICF Program, are summarized in this paper. 32 refs., 19 figs., 6 tabs

  18. Diagnostic imaging strategy for MDCT- or MRI-detected breast lesions: use of targeted sonography

    International Nuclear Information System (INIS)

    Nakano, Satoko; Ohtsuka, Masahiko; Mibu, Akemi; Karikomi, Masato; Sakata, Hitomi; Yamamoto, Masahiro

    2012-01-01

    Leading-edge technology such as magnetic resonance imaging (MRI) or computed tomography (CT) often reveals mammographically and ultrasonographically occult lesions. MRI is a well-documented, effective tool to evaluate these lesions; however, the detection rate of targeted sonography varies for MRI detected lesions, and its significance is not well established in diagnostic strategy of MRI detected lesions. We assessed the utility of targeted sonography for multidetector-row CT (MDCT)- or MRI-detected lesions in practice. We retrospectively reviewed 695 patients with newly diagnosed breast cancer who were candidates for breast conserving surgery and underwent MDCT or MRI in our hospital between January 2004 and March 2011. Targeted sonography was performed in all MDCT- or MRI-detected lesions followed by imaging-guided biopsy. Patient background, histopathology features and the sizes of the lesions were compared among benign, malignant and follow-up groups. Of the 695 patients, 61 lesions in 56 patients were detected by MDCT or MRI. The MDCT- or MRI-detected lesions were identified by targeted sonography in 58 out of 61 lesions (95.1%). Patients with pathological diagnoses were significantly older and more likely to be postmenopausal than the follow-up patients. Pathological diagnosis proved to be benign in 20 cases and malignant in 25. The remaining 16 lesions have been followed up. Lesion size and shape were not significantly different among the benign, malignant and follow-up groups. Approximately 95% of MDCT- or MRI-detected lesions were identified by targeted sonography, and nearly half of these lesions were pathologically proven malignancies in this study. Targeted sonography is a useful modality for MDCT- or MRI-detected breast lesions

  19. Polarized proton target-III. Operations manual, revision B

    International Nuclear Information System (INIS)

    Hill, D.; Moretti, A.; Onesto, F.; Rynes, P.

    1978-01-01

    The manual presented contains certain standard operating procedures for the vacuum, cryogenic, and electronic systems of PPT-III. In total, these systems comprise the following major divisions: (1) the target cryostat; (2) the 4 He pumping system; (3) the 3 He pumping system; (4) the remote monitors and controls; (5) the microwave system; (6) the magnet and power supply; (7) the computerized polarization monitor; (8) the 4 He liquefier and gas recovery system; and (9) miscellaneous auxiliary equipment

  20. Diagnostic value of PET and MRI in the differential diagnosis of diseases of the pancreas - assessment of their operability

    International Nuclear Information System (INIS)

    Dobrowolski, F.; Ockert, D.; Saeger, H.D.; Bredow, J.; Kropp, J.; Johannsen, B.

    2002-01-01

    In many cases the diagnostic findings cannot provide exact information concerning the possibility of surgical treatment. The number of feasible operations is small, but there is, on the other hand, a high rate of explorative laparotomy. To estimate the diagnostic value of [ 18 F]-FDG PET in these patients (pts.), the results of MRI were registered and compared with the histological findings (''gold standard''). (orig.)

  1. Effective diagnostic DAQ systems to reduce unnecessary data in KSTAR

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Taegu, E-mail: glory@nfri.re.kr; Lee, Woongryol; Hong, Jaesic; Park, Kaprai

    2016-11-15

    Highlights: • When plasma shots do not successfully perform during the intended target time, the diagnostics systems continue to record these unusable data, contributing to increasing data size. • To overcome this problem, some KSTAR’s library were upgraded to monitor the plasma status in real-time. • With the real-time information of plasma status, some of the KSTAR diagnostic systems stop the acquisition process of unnecessary data. • We were able to reduce the refuse data of approximately 698 GByte in the KSTAR 7th campaign. • It was a very effective way to store useful data, and it was helpful to analysts after shot. - Abstract: The plasma status of Korea Superconducting Tokamak Advanced Research (KSTAR) is measured by various diagnostics systems. The measured data size has been increasing every year due to increasing plasma pulse lengths, higher diagnostics operating frequencies, the additions of new diagnostic systems, and an increasing number of diagnostics channels. At times, when plasma shots do not successfully perform during the intended target time, the diagnostics systems continue to record these unusable data, contributing to increasing data size. In addition, the analysis time was affected, as these data need to be separated from the relevant data set. To overcome this problem, KSTAR’s Standard Framework (SFW), Real Time Monitoring (RTMON), and Pulse Automation and Scheduling System (PASS) were upgraded to monitor the plasma status in real-time. When the plasma current is less than 200kA, RTMON sends the plasma status information every second to the SFW via EPICS Channel Access. With the real-time information on plasma status, some of the KSTAR diagnostic systems stop the acquisition process of unnecessary data. This paper describes a method for reducing the storage of unnecessary data and its results in the KSTAR 7th campaign.

  2. Optical diagnostics of CO2 laser-fusion targets using backscattered light

    International Nuclear Information System (INIS)

    Casperson, D.E.

    1981-01-01

    With the f/2.4 focusing optics on one of the eight Helios CO 2 laser beam lines, direct backscattered light from a variety of glass microballoon targets has been observed. The quantities that have been measured include: (1) the total backscattered energy; (2) relative amplitudes of the backscattered fundamental and low harmonics (n = 1, 2, 3) of the 10.6 μm incident light; (3) the 3/2 harmonic emission from a double pulse backscatter experiment; (4) the temporally resolved 10.6 μm light using a fast pyroelectric detector and a Los Alamos 5-GHz oscilloscope; and (5) the time-integrated spectrally resolved fundamental using a 3/4 meter spectrometer and a high resolution pyroelectric detector array (resolution approx. 40 A at 10.6 μm). The suitability of these diagnostics for evaluating the CO 2 laser plasma in terms of stimulated scattering processes, plasma density gradients, velocity of the critical surface, etc., is discussed

  3. Design of Diagnostics: Case Studies for Wendelstein 7-X

    International Nuclear Information System (INIS)

    Dreier, H.; Dinklage, A.; Fischer, R.; Hirsch, M.; Kornejew, P.; Pasch, E.

    2005-01-01

    The set of start-up diagnostics for Wendelstein 7-X is oriented to resolve physical issues of stellarator optimization [1]. The diagnostics philosophy of W7-X aims at extendable set-ups which are to be supplemented along the operation of the device. Planning diagnostics directly lead to the requirement to optimize their respective outcome. In many cases, the optimization is much restricted by technical constraints. But even in those cases, figures of robustness of the chosen design settings are beneficial for the diagnostic strategy. In this paper a framework for diagnostic design is presented employing the Bayesian probability theory. Part of the approach can be regarded as a virtual diagnostic, which describes the future experimental unit including its error statistics and is able to produce artificial data. The virtual diagnostic is fed with mock-up quantities of interest and hence it enables the designer to compare the outcome of the virtual diagnostic with its input. For the design of diagnostics in fusion experiments several figures of merit are possible, depend- ing on the optimization goal. Here physical questions like estimation of the density distribution or the density gradient are possible optimization targets as well as technical issues as the robustness of density measurements, e.g, for controlling purposes. Also the estimation of derived quantities - like gradients needed for modeling of the bootstrap current or of the radial electric field - might be considered to be the goal of a diagnostic design. (Author)

  4. Design criteria of the bolometer diagnostic for steady-state operation of the W7-X stellaratora

    NARCIS (Netherlands)

    Zhang, D.; Burhenn, R.; König, R.; Giannone, L.; Grodzki, P.A.; Klein, B.; Grosser, K.; Baldzuhn, J.; Ewert, K.; Erckmann, V.; Hirsch, M.; Laqua, H.P.; Oosterbeek, J.W.

    2010-01-01

    A bolometric diagnostic system with features necessary for steady-state operation in the superconducting stellarator W7-X was designed. During a pulse length of 1800 s with an ECRH (electron cyclotron resonance heating) power of 10 MW, the components suffer not only from a large thermal load but

  5. First meeting on the CRP 'standardized high current solid targets for cyclotron production of diagnostic and therapeutic radionuclides'

    International Nuclear Information System (INIS)

    Winkel, P. van den

    2000-01-01

    The Cyclotron Department of the VUB has three groups performing research in the field of target development, production of radionuclides and their application in nuclear medicine. 1. The Physics Group is busy on the optimization of beam parameters, on the determination of cross sections and on neutron spectrometry. 2. The Inorganic Radiochemistry Group performs research on solid target electroplating (Tl, Zn, Cd, Rh ... ), on optimisation of target carrier geometry and cooling and on automated PC-controlled radiochemistry (Tl-201, Ga-67, In-111) and recovery systems and the associated software written in Modula-2 and Visual Basic. 3. The Organic Radiochemistry Group develops new techniques for radiolabelling of organic molecules (fatty acids, neuroleptics, synthetic polypeptides...) useful in diagnostic and therapeutic nuclear medicine. All three groups take part in bulk productions of radionuclides

  6. Detection algorithm of infrared small target based on improved SUSAN operator

    Science.gov (United States)

    Liu, Xingmiao; Wang, Shicheng; Zhao, Jing

    2010-10-01

    The methods of detecting small moving targets in infrared image sequences that contain moving nuisance objects and background noise is analyzed in this paper. A novel infrared small target detection algorithm based on improved SUSAN operator is put forward. The algorithm selects double templates for the infrared small target detection: one size is greater than the small target point size and another size is equal to the small target point size. First, the algorithm uses the big template to calculate the USAN of each pixel in the image and detect the small target, the edge of the image and isolated noise pixels; Then the algorithm uses the another template to calculate the USAN of pixels detected in the first step and improves the principles of SUSAN algorithm based on the characteristics of the small target so that the algorithm can only detect small targets and don't sensitive to the edge pixels of the image and isolated noise pixels. So the interference of the edge of the image and isolate noise points are removed and the candidate target points can be identified; At last, the target is detected by utilizing the continuity and consistency of target movement. The experimental results indicate that the improved SUSAN detection algorithm can quickly and effectively detect the infrared small targets.

  7. EU 2030 targets 'unachievable' without long-term nuclear operation

    Energy Technology Data Exchange (ETDEWEB)

    Mitev, Lubomir [NucNet, Brussels (Belgium)

    2015-01-15

    Nuclear energy will continue to support greenhouse gas emission reduction targets until 2020, but without decisions on long-term operation of ageing reactors, it will be difficult for the EU to meet its 2030 targets, International Energy Agency (IEA) executive director Maria van der Hoeven, tells NucNet in an interview. The IEA has quite a few remarks and questions related to the EU goals of competitiveness, security of supply and sustainability. It is good to have these targets, but up until now the EU is missing the direct connection between the three goals. What is mostly needed to achieve the goals is to finalise the EU's internal energy market. Secondly cost-effective climate and energy policies are needed because it is not only about climate and energy, but also about economic development and competitiveness. The ageing EU reactor fleet requires country-level and owner/operator-level decisions in the short term regarding plant safety regulations, plant upgrades, uprates, lifetime extensions and licence renewals. Upgrading and uprating existing nuclear plants is one of the cheapest ways of producing carbon-free electricity in the EU. Without long-term operation, the IEA expects nuclear capacity in the EU could fall by a factor of six by 2030 and that will make it more difficult to achieve the EU's 2030 climate targets. Public opinion is an important topic for the acceptance of all energy sources and it is different in all IEA member countries. Europe is very sensitive to almost all forms of energy, including wind turbines and solar panels. This is linked to a lack of information, so we need more and better transparency on information for people.

  8. Tumor Microenvironment Modulation via Gold Nanoparticles Targeting Malicious Exosomes: Implications for Cancer Diagnostics and Therapy

    Directory of Open Access Journals (Sweden)

    Catarina Roma-Rodrigues

    2017-01-01

    Full Text Available Exosomes are nanovesicles formed in the endosomal pathway with an important role in paracrine and autocrine cell communication. Exosomes secreted by cancer cells, malicious exosomes, have important roles in tumor microenvironment maturation and cancer progression. The knowledge of the role of exosomes in tumorigenesis prompted a new era in cancer diagnostics and therapy, taking advantage of the use of circulating exosomes as tumor biomarkers due to their stability in body fluids and targeting malignant exosomes’ release and/or uptake to inhibit or delay tumor development. In recent years, nanotechnology has paved the way for the development of a plethora of new diagnostic and therapeutic platforms, fostering theranostics. The unique physical and chemical properties of gold nanoparticles (AuNPs make them suitable vehicles to pursuit this goal. AuNPs’ properties such as ease of synthesis with the desired shape and size, high surface:volume ratio, and the possibility of engineering their surface as desired, potentiate AuNPs’ role in nanotheranostics, allowing the use of the same formulation for exosome detection and restraining the effect of malicious exosomes in cancer progression.

  9. Tumor Microenvironment Modulation via Gold Nanoparticles Targeting Malicious Exosomes: Implications for Cancer Diagnostics and Therapy.

    Science.gov (United States)

    Roma-Rodrigues, Catarina; Raposo, Luís R; Cabral, Rita; Paradinha, Fabiana; Baptista, Pedro V; Fernandes, Alexandra R

    2017-01-14

    Exosomes are nanovesicles formed in the endosomal pathway with an important role in paracrine and autocrine cell communication. Exosomes secreted by cancer cells, malicious exosomes, have important roles in tumor microenvironment maturation and cancer progression. The knowledge of the role of exosomes in tumorigenesis prompted a new era in cancer diagnostics and therapy, taking advantage of the use of circulating exosomes as tumor biomarkers due to their stability in body fluids and targeting malignant exosomes' release and/or uptake to inhibit or delay tumor development. In recent years, nanotechnology has paved the way for the development of a plethora of new diagnostic and therapeutic platforms, fostering theranostics. The unique physical and chemical properties of gold nanoparticles (AuNPs) make them suitable vehicles to pursuit this goal. AuNPs' properties such as ease of synthesis with the desired shape and size, high surface:volume ratio, and the possibility of engineering their surface as desired, potentiate AuNPs' role in nanotheranostics, allowing the use of the same formulation for exosome detection and restraining the effect of malicious exosomes in cancer progression.

  10. Study on a self diagnostic monitoring system for an air-operated valve: development of a fault library

    International Nuclear Information System (INIS)

    Chai, Jang Bom; Kim, Yun Chul; Kim, Woo Shik; Cho, Hang Duke

    2004-01-01

    In the interest of nuclear power plant safety, a Self-Diagnostic Monitoring System (SDMS) is needed to monitor defects in safety-related components. An Air-Operated Valve (AOV) is one of the components to be monitored since the failure of its operation could potentially have catastrophic consequences. In this paper, a model of the AOV is developed with the parameters that affect the operational characteristics. The model is useful for both understanding the operation and correlating parameters and defects. Various defects are introduced in the experiments to construct a fault library, which will be used in a pattern recognition approach. Finally, the validity of the fault library is examined

  11. Target motion predictions for pre-operative planning during needle-based interventions

    NARCIS (Netherlands)

    op den Buijs, J.; Abayazid, Momen; de Korte, Chris L.; Misra, Sarthak

    During biopsies, breast tissue is subjected to displacement upon needle indentation, puncture, and penetration. Thus, accurate needle placement requires pre-operative predictions of the target motions. In this paper, we used ultrasound elastography measurements to non-invasively predict elastic

  12. Computer simulation for the effect of target angle in diagnostic x-ray tube output and half-value layer

    International Nuclear Information System (INIS)

    Hayami, Akimune; Fuchihata, Hajime; Yamazaki, Takeshi; Mori, Yoshinobu; Ozeki, Syuji.

    1980-01-01

    The change of target angle of X-ray tube plays an important role in changing both the output and the quality of X-rays. A computer simulation was made to estimate the effect of target angle on the output and the quality (half-value layer: HVL) in the central ray using Storm's semiempirical formula. The data here presented are the values of output and HVL for the target angles of 10, 15, 20 and 30 degrees and for the total filtrations of 1, 2, 3 and 4 mm Al eq., at an increment of 10 kV steps of applied voltage between 50 and 150 kV. The output values and HVL's as a function of target angle, applied voltage and total filtration are shown for a full-wave rectified diagnostic X-ray generator. As a result, changes ranging from 17 to 76% in the output and 5 to 66% in the HVL were noted by varying the target angle from 10 to 30 degrees. Therefore, the target angle of X-ray tube should be clearly stated whenever the output and the quality (HVL) of X-ray generator are discussed. (author)

  13. Rapid molecular diagnostics of severe primary immunodeficiency determined by using targeted next-generation sequencing.

    Science.gov (United States)

    Yu, Hui; Zhang, Victor Wei; Stray-Pedersen, Asbjørg; Hanson, Imelda Celine; Forbes, Lisa R; de la Morena, M Teresa; Chinn, Ivan K; Gorman, Elizabeth; Mendelsohn, Nancy J; Pozos, Tamara; Wiszniewski, Wojciech; Nicholas, Sarah K; Yates, Anne B; Moore, Lindsey E; Berge, Knut Erik; Sorte, Hanne; Bayer, Diana K; ALZahrani, Daifulah; Geha, Raif S; Feng, Yanming; Wang, Guoli; Orange, Jordan S; Lupski, James R; Wang, Jing; Wong, Lee-Jun

    2016-10-01

    Primary immunodeficiency diseases (PIDDs) are inherited disorders of the immune system. The most severe form, severe combined immunodeficiency (SCID), presents with profound deficiencies of T cells, B cells, or both at birth. If not treated promptly, affected patients usually do not live beyond infancy because of infections. Genetic heterogeneity of SCID frequently delays the diagnosis; a specific diagnosis is crucial for life-saving treatment and optimal management. We developed a next-generation sequencing (NGS)-based multigene-targeted panel for SCID and other severe PIDDs requiring rapid therapeutic actions in a clinical laboratory setting. The target gene capture/NGS assay provides an average read depth of approximately 1000×. The deep coverage facilitates simultaneous detection of single nucleotide variants and exonic copy number variants in one comprehensive assessment. Exons with insufficient coverage (diagnostic yield of severe primary immunodeficiency. Establishing a molecular diagnosis enables early immune reconstitution through prompt therapeutic intervention and guides management for improved long-term quality of life. Copyright © 2016 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  14. Optical diagnostics in the advanced test accelerator (ATA) environment

    International Nuclear Information System (INIS)

    Chong, Y.P.; Cornish, J.P.; Donnelly, D.

    1987-05-01

    The ATA is a 50-MeV, 10-kA, 70-ns pulsed electron beam accelerator that generates an extremely harsh environment for diagnostic measurements. Diagnostic targets placed in the beamline are subject to damage, frequently being destroyed by a single pulse. High radiation (x-ray, gamma, and neutron) and electromagnetic interference levels preclude placing components near the beamline that are susceptible to radiation damage. Examples of such components are integrated circuit elements, hydrocarbons such as Teflon insulation, and optical components that darken, resulting in transmission loss. Optical diagnostics play an important part in measuring experimental parameters such as the beam current density profile. A large number of optical lines of sight (LOS) are routinely deployed along the experimental beamlines that use the ATA beam. Gated TV cameras are located outside the accelerator tunnel, because the tunnel is inaccessible during operations. We will describe and discuss the difficulties, problems, and solutions encountered in making optical measurements in the ATA environment

  15. Plasma diagnostic development and UHV testing for the ALPHA collaboration at Marquette University

    Science.gov (United States)

    Tharp, T. D.; Alpha Collaboration

    2017-10-01

    At Marquette, we are developing the next generation of nonneutral plasma diagnostics for the ALPHA experiment at CERN. ALPHA is building a new vertical experiment to test the gravitational interaction of antihydrogen with Earth. This expansion requires significant changes to the design of our plasma diagnostic suites: the next generation of tools must be able to measure plasmas from two directions, and must be capable of operating in a horizontal position. The diagnostic suite includes measurements of plasma density, shape, and temperature. The hardware used includes a MicroChannel Plate (MCP), a Faraday Cup, and an electron gun. In addition, we are building a vacuum chamber to test the viability of 3-d printed components for UHV compatibility, with target pressures of 10-10 mbar.

  16. Repetitive laser fusion experiment and operation using a target injection system

    International Nuclear Information System (INIS)

    Nishimura, Yasuhiko; Komeda, Osamu; Mori, Yoshitaka

    2017-01-01

    Since 2008, a collaborative research project on laser fusion development based on a high-speed ignition method using repetitive laser has been carried out with several collaborative research institutes. This paper reports the current state of operation of high repetition laser fusion experiments, such as target introduction and control based on a target injection system that allows free falling under 1 Hz, using a high repetition laser driver that has been under research and development, as well as the measurement of targets that freely fall. The HAMA laser driver that enabled high repetition fusion experiments is a titanium sapphire laser using a diode-pumped solid-state laser KURE-I of green light output as a driver pump light source. In order to carry out high repetition laser fusion experiments, the target injection device allows free falling of deuterated polystyrene solid sphere targets of 1 mm in diameter under 1 Hz. The authors integrated the developed laser and injection system, and succeeded first in the world in making the nuclear fusion reaction continuously by hitting the target to be injected with laser, which is essential technology for future laser nuclear fusion reactor. In order to realize repetition laser fusion experiments, stable laser, target synchronization control, and target position measurement technologies are indispensable. (A.O.)

  17. Receiver operating characteristic analysis of eyewitness memory: comparing the diagnostic accuracy of simultaneous versus sequential lineups.

    Science.gov (United States)

    Mickes, Laura; Flowe, Heather D; Wixted, John T

    2012-12-01

    A police lineup presents a real-world signal-detection problem because there are two possible states of the world (the suspect is either innocent or guilty), some degree of information about the true state of the world is available (the eyewitness has some degree of memory for the perpetrator), and a decision is made (identifying the suspect or not). A similar state of affairs applies to diagnostic tests in medicine because, in a patient, the disease is either present or absent, a diagnostic test yields some degree of information about the true state of affairs, and a decision is made about the presence or absence of the disease. In medicine, receiver operating characteristic (ROC) analysis is the standard method for assessing diagnostic accuracy. By contrast, in the eyewitness memory literature, this powerful technique has never been used. Instead, researchers have attempted to assess the diagnostic performance of different lineup procedures using methods that cannot identify the better procedure (e.g., by computing a diagnosticity ratio). Here, we describe the basics of ROC analysis, explaining why it is needed and showing how to use it to measure the performance of different lineup procedures. To illustrate the unique advantages of this technique, we also report 3 ROC experiments that were designed to investigate the diagnostic accuracy of simultaneous versus sequential lineups. According to our findings, the sequential procedure appears to be inferior to the simultaneous procedure in discriminating between the presence versus absence of a guilty suspect in a lineup.

  18. Whole Genome Sequencing Increases Molecular Diagnostic Yield Compared with Current Diagnostic Testing for Inherited Retinal Disease.

    Science.gov (United States)

    Ellingford, Jamie M; Barton, Stephanie; Bhaskar, Sanjeev; Williams, Simon G; Sergouniotis, Panagiotis I; O'Sullivan, James; Lamb, Janine A; Perveen, Rahat; Hall, Georgina; Newman, William G; Bishop, Paul N; Roberts, Stephen A; Leach, Rick; Tearle, Rick; Bayliss, Stuart; Ramsden, Simon C; Nemeth, Andrea H; Black, Graeme C M

    2016-05-01

    To compare the efficacy of whole genome sequencing (WGS) with targeted next-generation sequencing (NGS) in the diagnosis of inherited retinal disease (IRD). Case series. A total of 562 patients diagnosed with IRD. We performed a direct comparative analysis of current molecular diagnostics with WGS. We retrospectively reviewed the findings from a diagnostic NGS DNA test for 562 patients with IRD. A subset of 46 of 562 patients (encompassing potential clinical outcomes of diagnostic analysis) also underwent WGS, and we compared mutation detection rates and molecular diagnostic yields. In addition, we compared the sensitivity and specificity of the 2 techniques to identify known single nucleotide variants (SNVs) using 6 control samples with publically available genotype data. Diagnostic yield of genomic testing. Across known disease-causing genes, targeted NGS and WGS achieved similar levels of sensitivity and specificity for SNV detection. However, WGS also identified 14 clinically relevant genetic variants through WGS that had not been identified by NGS diagnostic testing for the 46 individuals with IRD. These variants included large deletions and variants in noncoding regions of the genome. Identification of these variants confirmed a molecular diagnosis of IRD for 11 of the 33 individuals referred for WGS who had not obtained a molecular diagnosis through targeted NGS testing. Weighted estimates, accounting for population structure, suggest that WGS methods could result in an overall 29% (95% confidence interval, 15-45) uplift in diagnostic yield. We show that WGS methods can detect disease-causing genetic variants missed by current NGS diagnostic methodologies for IRD and thereby demonstrate the clinical utility and additional value of WGS. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  19. National NIF Diagnostic Program Interim Management Plan

    International Nuclear Information System (INIS)

    Warner, B

    2002-01-01

    The National Ignition Facility (NIF) has the mission of supporting Stockpile Stewardship and Basic Science research in high-energy-density plasmas. To execute those missions, the facility must provide diagnostic instrumentation capable of observing and resolving in time events and radiation emissions characteristic of the plasmas of interest. The diagnostic instrumentation must conform to high standards of operability and reliability within the NIF environment. These exacting standards, together with the facility mission of supporting a diverse user base, has led to the need for a central organization charged with delivering diagnostic capability to the NIF. The National NIF Diagnostics Program (NNDP) has been set up under the aegis of the NIF Director to provide that organization authority and accountability to the wide user community for NIF. The funds necessary to perform the work of developing diagnostics for NIF will be allocated from the National NIF Diagnostics Program to the participating laboratories and organizations. The participating laboratories and organizations will design, build, and commission the diagnostics for NIF. Restricted availability of funding has had an adverse impact, unforeseen at the time of the original decision to projectize NIF Core Diagnostics Systems and Cryogenic Target Handing Systems, on the planning and initiation of these efforts. The purpose of this document is to provide an interim project management plan describing the organizational structure and management processes currently in place for NIF Core Diagnostics Systems. Preparation of a Program Execution Plan for NIF Core Diagnostics Systems has been initiated and a current draft is provided as Attachment 1 to this document. The National NIF Diagnostics Program Interim Management Plan provides a summary of primary design criteria and functional requirements, current organizational structure, tracking and reporting procedures, and current planning estimates of project scope

  20. Study of time-critical diagnostic method for emergency operation of nuclear power plant

    International Nuclear Information System (INIS)

    Gofuku, A.; Yoshikawa, H.; Itoh, K.; Wakabayashi, J.

    1986-01-01

    In order to support the emergency operation of nuclear power plant, the method of time-critical diagnostic plant analyzer has been investigated. The conception of the emergency operation support center is proposed and two types of plant analyzer may be installed in this center. One analyzer is a real-time tracking simulation code using the observed signals and another is a fast trend-prediction code. A real-time tracking code, TOKRAC, has been developed for analyzing the PWR primary loop thermo-hydraulics at SBLOCA, and the applicability of this code was examined by the numerical experiments for the initial phase transient of both TMI-2 accident and 6% coldleg SBLOCA of a Westinghouse-type PWR plant. The results showed that fairly good tracking was carried out by TOKRAC. The CPU time of TOKRAC was about 12-14 percent of real-time

  1. Using Targeted Active-Learning Exercises and Diagnostic Question Clusters to Improve Students' Understanding of Carbon Cycling in Ecosystems

    Science.gov (United States)

    Maskiewicz, April Cordero; Griscom, Heather Peckham; Welch, Nicole Turrill

    2012-01-01

    In this study, we used targeted active-learning activities to help students improve their ways of reasoning about carbon flow in ecosystems. The results of a validated ecology conceptual inventory (diagnostic question clusters [DQCs]) provided us with information about students' understanding of and reasoning about transformation of inorganic and organic carbon-containing compounds in biological systems. These results helped us identify specific active-learning exercises that would be responsive to students' existing knowledge. The effects of the active-learning interventions were then examined through analysis of students' pre- and postinstruction responses on the DQCs. The biology and non–biology majors participating in this study attended a range of institutions and the instructors varied in their use of active learning; one lecture-only comparison class was included. Changes in pre- to postinstruction scores on the DQCs showed that an instructor's teaching method had a highly significant effect on student reasoning following course instruction, especially for questions pertaining to cellular-level, carbon-transforming processes. We conclude that using targeted in-class activities had a beneficial effect on student learning regardless of major or class size, and argue that using diagnostic questions to identify effective learning activities is a valuable strategy for promoting learning, as gains from lecture-only classes were minimal. PMID:22383618

  2. Using targeted active-learning exercises and diagnostic question clusters to improve students' understanding of carbon cycling in ecosystems.

    Science.gov (United States)

    Maskiewicz, April Cordero; Griscom, Heather Peckham; Welch, Nicole Turrill

    2012-01-01

    In this study, we used targeted active-learning activities to help students improve their ways of reasoning about carbon flow in ecosystems. The results of a validated ecology conceptual inventory (diagnostic question clusters [DQCs]) provided us with information about students' understanding of and reasoning about transformation of inorganic and organic carbon-containing compounds in biological systems. These results helped us identify specific active-learning exercises that would be responsive to students' existing knowledge. The effects of the active-learning interventions were then examined through analysis of students' pre- and postinstruction responses on the DQCs. The biology and non-biology majors participating in this study attended a range of institutions and the instructors varied in their use of active learning; one lecture-only comparison class was included. Changes in pre- to postinstruction scores on the DQCs showed that an instructor's teaching method had a highly significant effect on student reasoning following course instruction, especially for questions pertaining to cellular-level, carbon-transforming processes. We conclude that using targeted in-class activities had a beneficial effect on student learning regardless of major or class size, and argue that using diagnostic questions to identify effective learning activities is a valuable strategy for promoting learning, as gains from lecture-only classes were minimal.

  3. DIAGNOSTICS FOR ION BEAM DRIVEN HIGH ENERGY DENSITY PHYSICS EXPERIMENTS

    International Nuclear Information System (INIS)

    Bieniosek, F.M.; Henestroza, E.; Lidia, S.; Ni, P.A.

    2010-01-01

    Intense beams of heavy ions are capable of heating volumetric samples of matter to high energy density. Experiments are performed on the resulting warm dense matter (WDM) at the NDCX-I ion beam accelerator. The 0.3 MeV, 30-mA K + beam from NDCX-I heats foil targets by combined longitudinal and transverse neutralized drift compression of the ion beam. Both the compressed and uncompressed parts of the NDCX-I beam heat targets. The exotic state of matter (WDM) in these experiments requires specialized diagnostic techniques. We have developed a target chamber and fielded target diagnostics including a fast multi-channel optical pyrometer, optical streak camera, laser Doppler-shift interferometer (VISAR), beam transmission diagnostics, and high-speed gated cameras. We also present plans and opportunities for diagnostic development and a new target chamber for NDCX-II.

  4. SNS Diagnostics Tools for Data Acquisition and Display

    CERN Document Server

    Sundaram, Madhan; Long, Cary D

    2005-01-01

    The Spallation Neutron Source (SNS) accelerator systems will deliver a 1.0 GeV, 1.4 MW proton beam to a liquid mercury target for neutron scattering research. The accelerator complex consists of a 1.0 GeV linear accelerator, an accumulator ring and associated transport lines. The SNS diagnostics platform is PC-based and will run Windows for its OS and LabVIEW as its programming language. The diagnostics platform as well as other control systems and operator consoles use the Channel Access (CA) protocol of the Experimental Physics and Industrial Control System (EPICS) to communicate. This paper describes the tools created to evaluate the diagnostic instrument using our standard programming environment, LabVIEW. The tools are based on the LabVIEW Channel Access library and can run on Windows, Linux, and Mac OS X. The data-acquisition tool uses drop and drag to select process variables organized by instrument, accelerator component, or beam parameters. The data can be viewed on-line and logged to disk for later ...

  5. ITER diagnostic system: Vacuum interface

    Energy Technology Data Exchange (ETDEWEB)

    Patel, K.M., E-mail: Kaushal.Patel@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Udintsev, V.S.; Hughes, S.; Walker, C.I.; Andrew, P.; Barnsley, R.; Bertalot, L. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Drevon, J.M. [Bertin Technologies, BP 22, 13762 Aix-en Provence cedex 3 (France); Encheva, A. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Kashchuk, Y. [Institution “PROJECT CENTER ITER”, 1, Akademika Kurchatova pl., Moscow (Russian Federation); Maquet, Ph. [Bertin Technologies, BP 22, 13762 Aix-en Provence cedex 3 (France); Pearce, R.; Taylor, N.; Vayakis, G.; Walsh, M.J. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France)

    2013-10-15

    Diagnostics play an essential role for the successful operation of the ITER tokamak. They provide the means to observe control and to measure plasma during the operation of ITER tokamak. The components of the diagnostic system in the ITER tokamak will be installed in the vacuum vessel, in the cryostat, in the upper, equatorial and divertor ports, in the divertor cassettes and racks, as well as in various buildings. Diagnostic components that are placed in a high radiation environment are expected to operate for the life of ITER. There are approx. 45 diagnostic systems located on ITER. Some diagnostics incorporate direct or independently pumped extensions to maintain their necessary vacuum conditions. They require a base pressure less than 10{sup −7} Pa, irrespective of plasma operation, and a leak rate of less than 10{sup −10} Pa m{sup 3} s{sup −1}. In all the cases it is essential to maintain the ITER closed fuel cycle. These directly coupled diagnostic systems are an integral part of the ITER vacuum containment and are therefore subject to the same design requirements for tritium and active gas confinement, for all normal and accidental conditions. All the diagnostics, whether or not pumped, incorporate penetration of the vacuum boundary (i.e. window assembly, vacuum feedthrough etc.) and demountable joints. Monitored guard volumes are provided for all elements of the vacuum boundary that are judged to be vulnerable by virtue of their construction, material, load specification etc. Standard arrangements are made for their construction and for the monitoring, evacuating and leak testing of these volumes. Diagnostic systems are incorporated at more than 20 ports on ITER. This paper will describe typical and particular arrangements of pumped diagnostic and monitored guard volume. The status of the diagnostic vacuum systems, which are at the start of their detailed design, will be outlined and the specific features of the vacuum systems in ports and extensions

  6. ITER diagnostic system: Vacuum interface

    International Nuclear Information System (INIS)

    Patel, K.M.; Udintsev, V.S.; Hughes, S.; Walker, C.I.; Andrew, P.; Barnsley, R.; Bertalot, L.; Drevon, J.M.; Encheva, A.; Kashchuk, Y.; Maquet, Ph.; Pearce, R.; Taylor, N.; Vayakis, G.; Walsh, M.J.

    2013-01-01

    Diagnostics play an essential role for the successful operation of the ITER tokamak. They provide the means to observe control and to measure plasma during the operation of ITER tokamak. The components of the diagnostic system in the ITER tokamak will be installed in the vacuum vessel, in the cryostat, in the upper, equatorial and divertor ports, in the divertor cassettes and racks, as well as in various buildings. Diagnostic components that are placed in a high radiation environment are expected to operate for the life of ITER. There are approx. 45 diagnostic systems located on ITER. Some diagnostics incorporate direct or independently pumped extensions to maintain their necessary vacuum conditions. They require a base pressure less than 10 −7 Pa, irrespective of plasma operation, and a leak rate of less than 10 −10 Pa m 3 s −1 . In all the cases it is essential to maintain the ITER closed fuel cycle. These directly coupled diagnostic systems are an integral part of the ITER vacuum containment and are therefore subject to the same design requirements for tritium and active gas confinement, for all normal and accidental conditions. All the diagnostics, whether or not pumped, incorporate penetration of the vacuum boundary (i.e. window assembly, vacuum feedthrough etc.) and demountable joints. Monitored guard volumes are provided for all elements of the vacuum boundary that are judged to be vulnerable by virtue of their construction, material, load specification etc. Standard arrangements are made for their construction and for the monitoring, evacuating and leak testing of these volumes. Diagnostic systems are incorporated at more than 20 ports on ITER. This paper will describe typical and particular arrangements of pumped diagnostic and monitored guard volume. The status of the diagnostic vacuum systems, which are at the start of their detailed design, will be outlined and the specific features of the vacuum systems in ports and extensions will be described

  7. Evaluation of Radiation Exposure Hazard from Squaw Targets Used in Operations WIGWAM and HARDTACK-1

    Science.gov (United States)

    2016-07-01

    targets during hull-damage testing at the underwater nuclear detonation at Operation WIGWAM, a deep underwater nuclear test conducted as part of the...1945–1962 United States series of atmospheric nuclear tests (DTRA, 2014; USAF, 1955). In preparation for the Operation WIGWAM test, the three...Weary et al., 1981, Figure 1-4) 6 In 1958, SQUAW-29 was used again as a submerged target at a nuclear detonation . This took place at Enewetak

  8. Evaluation of Radiation Exposure Hazard from Squaw Targets Used in Operations WIGWAM and HARDTACK-I

    Science.gov (United States)

    2016-07-01

    targets during hull-damage testing at the underwater nuclear detonation at Operation WIGWAM, a deep underwater nuclear test conducted as part of the...1945–1962 United States series of atmospheric nuclear tests (DTRA, 2014; USAF, 1955). In preparation for the Operation WIGWAM test, the three...Weary et al., 1981, Figure 1-4) 6 In 1958, SQUAW-29 was used again as a submerged target at a nuclear detonation . This took place at Enewetak

  9. MicroRNAs as diagnostic markers and therapeutic targets for traumatic brain injury

    Directory of Open Access Journals (Sweden)

    Bridget Martinez

    2017-01-01

    Full Text Available Traumatic brain injury (TBI is characterized by primary damage to the brain from the external mechanical force and by subsequent secondary injury due to various molecular and pathophysiological responses that eventually lead to neuronal cell death. Secondary brain injury events may occur minutes, hours, or even days after the trauma, and provide valuable therapeutic targets to prevent further neuronal degeneration. At the present time, there is no effective treatment for TBI due, in part, to the widespread impact of numerous complex secondary biochemical and pathophysiological events occurring at different time points following the initial injury. MicroRNAs control a range of physiological and pathological functions such as development, differentiation, apoptosis and metabolism, and may serve as potential targets for progress assessment and intervention against TBI to mitigate secondary damage to the brain. This has implications regarding improving the diagnostic accuracy of brain impairment and long-term outcomes as well as potential novel treatments. Recent human studies have identified specific microRNAs in serum/plasma (miR-425-p, -21, -93, -191 and -499 and cerebro-spinal fluid (CSF (miR-328, -362-3p, -451, -486a as possible indicators of the diagnosis, severity, and prognosis of TBI. Experimental animal studies have examined specific microRNAs as biomarkers and therapeutic targets for moderate and mild TBI (e.g., miR-21, miR-23b. MicroRNA profiling was altered by voluntary exercise. Differences in basal microRNA expression in the brain of adult and aged animals and alterations in response to TBI (e.g., miR-21 have also been reported. Further large-scale studies with TBI patients are needed to provide more information on the changes in microRNA profiles in different age groups (children, adults, and elderly.

  10. User interface graphically improves generator AL diagnostics

    International Nuclear Information System (INIS)

    Gray, R.F.; King, I.J.

    1991-01-01

    In April of 1990, the recently developed Diagnostic Graphical User Interface (DGUI) was installed at a large nuclear power plant in the midwestern United States. Since 1988, the power plant has been using the Generator Artificial Intelligence Diagnostics (GenAID) System, which provides online diagnostic capability for the generator and generator auxiliaries through a plant data center (PDC) and communication link to the diagnostic operations center (DOC) in Orlando, Florida. The enhanced system provides the power plant control room operator with a comprehensive tool to understand and better utilize the information provided by the existing knowledge bases. This paper represents a significant improvement over existing technology by providing the power plant control room operator with the capability of interacting directly with the diagnostic system

  11. Companion diagnostics

    DEFF Research Database (Denmark)

    Jørgensen, Jan Trøst; Hersom, Maria

    2016-01-01

    of disease mechanisms, things are slowly changing. Within the last few years, we have seen an increasing number of predictive biomarker assays being developed to guide the use of targeted cancer drugs. This type of assay is called companion diagnostics and is developed in parallel to the drug using the drug-diagnostic...... co-development model. The development of companion diagnostics is a relatively new discipline and in this review, different aspects will be discussed including clinical and regulatory issues. Furthermore, examples of drugs, such as the ALK and PD-1/PD-L1 inhibitors, that have been approved recently....... Despite having discussed personalized medicine for more than a decade, we still see that most drug prescriptions for severe chronic diseases are largely based on 'trial and error' and not on solid biomarker data. However, with the advance of molecular diagnostics and a subsequent increased understanding...

  12. Comparative survey of site and personnel monitoring characteristics for operation of various types of diagnostic-X ray equipment

    International Nuclear Information System (INIS)

    Lyarskij, P.P.; Zol'nikova, N.I.

    1977-01-01

    Diagnostic X-ray machines in present use at medical facilities differ in design and operating parameters, this diversity producing, in turn, a variety of local radiological situations and levels of personnel exposure. Based on radiological safety characterization of working conditions, the authors present a breakdown of contemporary diagnostic X-ray equipment types, based on detailed examination of each group in terms of their associated site monitoring and dosimetry patterns. The paper reports data on personnel exposure levels not only as a function of equipment design and operating characteristics but also according to types of occupational activities for particular medical personnel groups (radiologists, surgeons, anesthesiologists, etc.). Included are health physics data for domestic and foreign X-ray equipment, levels of local and absorbed doses for radiologists, cardiovascular surgeons, neurosurgeons, urologists, traumatologists, anesthesiologists, etc. Measures are recommended for optimizing their activities from the standpoint of radiation safety. (author)

  13. Operation Request Gatekeeper: A software system for remote access control of diagnostic instruments in fusion experiments

    International Nuclear Information System (INIS)

    Abla, G.; Schissel, D. P.; Fredian, T. W.; Stillerman, J. A.; Greenwald, M. J.; Stepanov, D. N.; Ciarlette, D. J.

    2010-01-01

    Tokamak diagnostic settings are repeatedly modified to meet the changing needs of each experiment. Enabling the remote diagnostic control has significant challenges due to security and efficiency requirements. The Operation Request Gatekeeper (ORG) is a software system that addresses the challenges of remotely but securely submitting modification requests. The ORG provides a framework for screening all the requests before they enter the secure machine zone and are executed by performing user authentication and authorization, grammar validation, and validity checks. A prototype ORG was developed for the ITER CODAC that satisfies their initial requirements for remote request submission and has been tested with remote control of the KSTAR Plasma Control System. This paper describes the software design principles and implementation of ORG as well as worldwide test results.

  14. Heated probe diagnostic inside of the gas aggregation nanocluster source

    Science.gov (United States)

    Kolpakova, Anna; Shelemin, Artem; Kousal, Jaroslav; Kudrna, Pavel; Tichy, Milan; Biederman, Hynek; Surface; Plasma Science Team

    2016-09-01

    Gas aggregation cluster sources (GAS) usually operate outside common working conditions of most magnetrons and the size of nanoparticles created in GAS is below that commonly studied in dusty plasmas. Therefore, experimental data obtained inside the GAS are important for better understanding of process of nanoparticles formation. In order to study the conditions inside the gas aggregation chamber, special ``diagnostic GAS'' has been constructed. It allows simultaneous monitoring (or spatial profiling) by means of optical emission spectroscopy, mass spectrometry and probe diagnostic. Data obtained from Langmuir and heated probes map the plasma parameters in two dimensions - radial and axial. Titanium has been studied as an example of metal for which the reactive gas in the chamber starts nanoparticles production. Three basic situations were investigated: sputtering from clean titanium target in argon, sputtering from partially pre-oxidized target and sputtering with oxygen introduced into the discharge. It was found that during formation of nanoparticles the plasma parameters differ strongly from the situation without nanoparticles. These experimental data will support the efforts of more realistic modeling of the process. Czech Science Foundation 15-00863S.

  15. Cannonball target experiment with the GEKKO laser system at ILE Osaka

    International Nuclear Information System (INIS)

    Yamanaka, C.; Azechi, H.; Fujiwara, E.

    1985-01-01

    The GEKKO series glass laser systems are now in operation for the Cannonball target experiments. GEKKO XII is a twelve-beam 30 kJ, 50 TW laser provided with two target chambers. Three types of GEKKO lasers cover the UV, blue, green and red frequency ranges. The Cannonball target displays an excellent performance in implosion. Two kinds of Cannonball target are proposed: the plasma Cannonball and the radiation Cannonball. The neutron yield is 4x10 10 , and the DT fuel density attains 10 g.cm -3 . Laser-to-X-ray conversion has been investigated. Cryogenic target implosion has been performed by using a tailored laser pulse to produce the flush at the core. Various kinds of new diagnostics are being developed. (author)

  16. Diagnostic Strategy in APR1400

    International Nuclear Information System (INIS)

    Kim, Dongyoung; Kim, Jonghyun

    2013-01-01

    These features may bring out changes in operator tasks, changing the characteristics of tasks, or creating new tasks. Diagnostic strategy for identifying anomaly may be different especially in APR1400 from that in the analog control room due to the change of human-system interface, i.e. alarm system and display system. Since the first plant of APR1400 is being built at this moment, it is not known what strategies the operators will adopt in diagnosis tasks in the new operating environment. In this light, this paper aims at investigating operator's diagnostic strategies which are appropriate for APR1400. In order to collect data, several different approaches which are complementary are used to identify diagnostic strategies in the digital control room: analysis on audio/video recording of operation, observation in the simulator, and interview with the operators. The result shows that the digital control room introduces new strategies in the diagnosis, compared with the analog control room, and also changed the characteristics of strategies, mostly, by getting more support from the computerized system. This paper investigated how the digitalized control room may influence operator's diagnostic strategies. Several different approaches, i. e., audio/video record, observation of training, and the interview with operators, were used to gather information about the operator's behaviors. As a conclusion, this paper figured out that the digital control room introduces new strategies in the diagnosis, compared with the analog control room, and also changed the characteristics of the strategies, mostly, by getting more support from the computerized system. The operators interviewed also commented that the diagnosis in the APR1400 is quicker, more correct, and easier, compared with the analog control room

  17. Targeted neurosurgical outreach: 5-year follow-up of operative skill transfer and sustainable care in Lima, Peru.

    Science.gov (United States)

    Duenas, Vincent J; Hahn, Edward J; Aryan, Henry E; Levy, Michael V; Jandial, Rahul

    2012-08-01

    This study evaluates the efficacy of operative skill transfer in the context of targeted pediatric outreach missions. In addition, the ability to implement surgical care improvements that are sustainable is investigated. Three 1-week targeted neurosurgical missions were performed (2004-2006) to teach neuroendoscopy, which included donation of the necessary equipment so newly acquired surgical skills could be performed by local neurosurgeons in between and after the departure of the mission team. After the targeted missions were completed, 5 years of neuroendoscopy case follow-up data were obtained. After performing pediatric neurosurgery missions in 2004-2006, with a focus on teaching neuroendoscopy, the host team demonstrated the sustainability of our didactic efforts in the subsequent 5 years by performing cases independently for their citizens. To date, a total of 196 operations have been performed in the past 5 years independent of any visiting team. Effective operative skill transfer to host neurosurgeons can be accomplished with limited international team visits utilizing a targeted approach that minimizes expenditures on personnel and capital. With the priority being teaching of an operative technique, as opposed to perennially performing operations by the mission team, sustainable surgical care was achieved after missions officially concluded.

  18. Hybrid operating room concept for combined diagnostics, intervention and surgery in acute type A dissection.

    Science.gov (United States)

    Tsagakis, Konstantinos; Konorza, Thomas; Dohle, Daniel Sebastian; Kottenberg, Eva; Buck, Thomas; Thielmann, Matthias; Erbel, Raimund; Jakob, Heinz

    2013-02-01

    In acute type A dissection (AAAD), it is commonly decided to carry out immediate surgical repair without invasive diagnostics. The hybrid operating room (Hybrid OR) concept encompasses simultaneous haemodynamic control, non-invasive and invasive diagnostics and immediate surgical and/or interventional treatment. Results over a seven-year period are presented here. From March 2004 to March 2011, 1883 cardiological and surgical patients were treated in a Hybrid OR. Of these, 124 patients (age 60 ± 13, 64% male) diagnosed with AAAD were operated upon. External computed tomography (CT) was available for 87% (108/124) of cases and angiography in 15% (19/124). Preoperative transoesophageal echocardiography (TEE) was done in all patients and angiography in 57% (71/124). Surgery was performed without angiography in 27% (34/124), of which 14% (17/124) was due to shock. Postoperative control angiography followed in 18% (22/124) due to suspected ongoing malperfusion. Preoperative angiography was performed in 71 patients, and no angiography related complications were observed during the procedure. A total of 32% (23/71) of these underwent coronary artery bypass graft (CABG)--for newly-diagnosed coronary artery disease in 21% of cases and for coronary malperfusion in 11%. Visceral/peripheral malperfusion syndromes, necessitating primary endovascular intervention, were detected in 23% (16/71). Ascending aorta replacement was performed in 100% (124/124) of patients, arch replacement in 88% (109/124) and descending aorta repair in 35% (44/124). Five postoperative endovascular interventions became necessary due to persistent malperfusion. In-hospital mortality was 13% (12/90) in patients who had undergone preoperative invasive diagnostics and 24% (8/34) in patients who had not. The Hybrid OR concept enables the exact diagnosis of coronary status and downstream malperfusion sites and influences the design of surgical and/or endovascular treatment, without time delay and at

  19. Invasion-Related Factors as Potential Diagnostic and Therapeutic Targets in Oral Squamous Cell Carcinoma—A Review

    Science.gov (United States)

    Siriwardena, Samadarani B. S. M.; Tsunematsu, Takaaki; Qi, Guangying; Ishimaru, Naozumi; Kudo, Yasusei

    2018-01-01

    It is well recognized that the presence of cervical lymph node metastasis is the most important prognostic factor in oral squamous cell carcinoma (OSCC). In solid epithelial cancer, the first step during the process of metastasis is the invasion of cancer cells into the underlying stroma, breaching the basement membrane (BM)—the natural barrier between epithelium and the underlying extracellular matrix (ECM). The ability to invade and metastasize is a key hallmark of cancer progression, and the most complicated and least understood. These topics continue to be very active fields of cancer research. A number of processes, factors, and signaling pathways are involved in regulating invasion and metastasis. However, appropriate clinical trials for anti-cancer drugs targeting the invasion of OSCC are incomplete. In this review, we summarize the recent progress on invasion-related factors and emerging molecular determinants which can be used as potential for diagnostic and therapeutic targets in OSCC. PMID:29758011

  20. Intra-operative X-ray diagnostics in the detection and localization of residual concretions in the kidney

    International Nuclear Information System (INIS)

    Soekeland, J.; Degenhardt, W.

    1979-01-01

    Problems of intra-operative X-ray diagnostics in the detection and localization of residual concretions in the kidney are discussed, together with the limitations of image-intensifier techniques, automatic exposure control, and the use of modified dental X-ray equipment. A technique using a film-screen combination and X-ray tube designed for mammography is discussed, together with its applications and possible future development. (Auth.)

  1. Influence of ion source configuration and its operation parameters on the target sputtering and implantation process.

    Science.gov (United States)

    Shalnov, K V; Kukhta, V R; Uemura, K; Ito, Y

    2012-06-01

    In the work, investigation of the features and operation regimes of sputter enhanced ion-plasma source are presented. The source is based on the target sputtering with the dense plasma formed in the crossed electric and magnetic fields. It allows operation with noble or reactive gases at low pressure discharge regimes, and, the resulting ion beam is the mixture of ions from the working gas and sputtering target. Any conductive material, such as metals, alloys, or compounds, can be used as the sputtering target. Effectiveness of target sputtering process with the plasma was investigated dependently on the gun geometry, plasma parameters, and the target bias voltage. With the applied accelerating voltage from 0 to 20 kV, the source can be operated in regimes of thin film deposition, ion-beam mixing, and ion implantation. Multi-component ion beam implantation was applied to α-Fe, which leads to the surface hardness increasing from 2 GPa in the initial condition up to 3.5 GPa in case of combined N(2)-C implantation. Projected range of the implanted elements is up to 20 nm with the implantation energy 20 keV that was obtained with XPS depth profiling.

  2. Summary Report on Synchronization, Diagnostics and Instrumentation

    International Nuclear Information System (INIS)

    Arne Freyberger

    2005-01-01

    The proceedings of Working Group 4 of the 2005 Energy Recovery Linac (ERL) workshop are summarized. Working Group 4 dealt with the challenging topic of beam diagnostics for ERL machines. Energy Recovery Linacs represent a challenge for beam diagnostics from several perspectives; invasive versus non-invasive diagnostics, longitudinal and transverse beam diagnostics, overall machine timing/synchronization and machine protection. Beam diagnostics for an ERL can benefit strongly from the experience at third generation light sources, recirculating linacs and presently operating ERLs. During the workshop there were presentations from all these communities, representing a large range operation experience in beam diagnostics. A brief summary Working Group 4 discussion is presented in this paper

  3. Cognitive Function as a Trans-Diagnostic Treatment Target in Stimulant Use Disorders

    Science.gov (United States)

    Sofuoglu, Mehmet; DeVito, Elise E.; Waters, Andrew J.; Carroll, Kathleen M.

    2016-01-01

    Stimulant use disorder is an important public health problem, with an estimated 2.1 million current users in the United States alone. No pharmacological treatments are approved by the U.S. Food and Drug Administration (FDA) for stimulant use disorder and behavioral treatments have variable efficacy and limited availability. Most individuals with stimulant use disorder have other comorbidities, most with overlapping symptoms and cognitive impairments. The goal of this article is to present a rationale for cognition as a treatment target in stimulant use disorder, and to outline potential treatment approaches. Rates of lifetime comorbid psychiatric disorders among people with stimulant use disorders are estimated at 65% - 73%, with the most common being mood disorders (13% - 64%) and anxiety disorders (21% - 50%), as well as non-substance induced psychotic disorders (under 10%). There are several models of addictive behavior, but the dual process model particularly highlights the relevance of cognitive impairments and biases to the development and maintenance of addiction. This model explains addictive behavior as a balance between automatic processes and executive control, which in turn are related to individual (genetics, comorbid disorders, psychosocial factors) and other (craving, triggers, drug use) factors. Certain cognitive impairments, such as attentional bias and approach bias, are most relevant to automatic processes, while sustained attention, response inhibition, and working memory are primarily related to executive control. These cognitive impairments and biases are also common in disorders frequently comorbid with stimulant use disorder, and predict poor treatment retention and clinical outcomes. As such, they may serve as feasible trans-diagnostic treatment targets. There are promising pharmacological, cognitive, and behavioral approaches that aim to enhance cognitive function. Pharmacotherapies target cognitive impairments associated with executive

  4. Evaluation of the diagnostic performance and operational characteristics of four rapid immunochromatographic syphilis tests in Burkina Faso.

    Science.gov (United States)

    Bocoum, Fadima Yaya; Ouédraogo, Henri; Tarnagda, Grissoum; Kiba, Alice; Tiendrebeogo, Simon; Bationo, Fabrice; Liestman, Benjamin; Diagbouga, Serge; Zarowsky, Christina; Traoré, Ramata Ouédraogo; Kouanda, Séni

    2015-06-01

    Little information is available on the rapid diagnostic testing for syphilis in Burkina Faso. The objectives of the study were (i) to assess the sensitivity and specificity of four on site rapid tests in comparison with Treponema pallidum haemagglutination assay (TPHA) as a gold standard and (ii) to evaluate the operational characteristics of those tests among health workers in a maternity unit. Four rapid syphilis tests commercially available in Burkina Faso were evaluated using archived serum samples and Treponema pallidum hemagglutination assay (TPHA) as the gold standard. Blood samples were collected between November 2011 and June 2012 from blood donors at the Regional Blood Transfusion Center of Ouagadougou. The sensitivity and specificity of the tests were calculated. Evaluation of operational characteristics such as clarity of pamphlet, complexity of technique, duration, was conducted in a first-level healthcare center with health workers in maternity unit. Alere DetermineTM Syphilis was the most sensitive of the four rapid syphilis tests evaluated. It was followed by SD Bioline Syphilis 3.0, Cypress Diagnostics Syphilis Quick test and Accu-Tell ® Rapid Anti-TP, which was the least sensitive. The four tests demonstrated a good diagnostic specificity for syphilis (95-98%), and healthcare workers found them easy to use. The study allowed confirming the good performance of three of four rapid syphilis tests in Burkina Faso. More research will be conducted to assess the feasibility of introducing selected rapid tests for syphilis in antenatal care services.

  5. A pin diode x-ray camera for laser fusion diagnostic imaging: Final technical report

    International Nuclear Information System (INIS)

    Jernigan, J.G.

    1987-01-01

    An x-ray camera has been constructed and tested for diagnostic imaging of laser fusion targets at the Laboratory for Laser Energetics (LLE) of the University of Rochester. The imaging detector, developed by the Hughes Aircraft Company, is a germanium PIN diode array of 10 x 64 separate elements which are bump bonded to a silicon readout chip containing a separate low noise amplifier for each pixel element. The camera assembly consists of a pinhole alignment mechanism, liquid nitrogen cryostat with detector mount and a thin beryllium entrance window, and a shielded rack containing the analog and digital electronics for operations. This x-ray camera has been tested on the OMEGA laser target chamber, the primary laser target facility of LLE, and operated via an Ethernet link to a SUN Microsystems workstation. X-ray images of laser targets are presented. The successful operation of this particular x-ray camera is a demonstration of the viability of the hybrid detector technology for future imaging and spectroscopic applications. This work was funded by the Department of Energy (DOE) as a project of the National Laser Users Facility (NLUF)

  6. Nike Facility Diagnostics and Data Acquisition System

    Science.gov (United States)

    Chan, Yung; Aglitskiy, Yefim; Karasik, Max; Kehne, David; Obenschain, Steve; Oh, Jaechul; Serlin, Victor; Weaver, Jim

    2013-10-01

    The Nike laser-target facility is a 56-beam krypton fluoride system that can deliver 2 to 3 kJ of laser energy at 248 nm onto targets inside a two meter diameter vacuum chamber. Nike is used to study physics and technology issues related to laser direct-drive ICF fusion, including hydrodynamic and laser-plasma instabilities, material behavior at extreme pressures, and optical and x-ray diagnostics for laser-heated targets. A suite of laser and target diagnostics are fielded on the Nike facility, including high-speed, high-resolution x-ray and visible imaging cameras, spectrometers and photo-detectors. A centrally-controlled, distributed computerized data acquisition system provides robust data management and near real-time analysis feedback capability during target shots. Work supported by DOE/NNSA.

  7. Diagnostics for FIRE: A Status Report

    International Nuclear Information System (INIS)

    Kenneth M. Young

    2002-01-01

    The mission for the proposed FIRE (Fusion Ignition Research Experiment) device is to ''attain, explore, understand and optimize fusion-dominated plasmas.'' Operation at Q * 5, for 20 sec with a fusion power output of *150 MW is the major goal. Attaining this mission sets demands for plasma measurement that are at least as comprehensive as on present tokamaks, with the additional capabilities needed for control of the plasma and for understanding the effects of the alpha-particles. Because of the planned operation in advanced tokamak scenarios, with steep transport barriers, the diagnostic instrumentation must be able to provide fine spatial and temporal resolution. It must also be able to withstand the impact of the intense neutron and gamma irradiation. There are practical engineering issues of minimizing radiation streaming while providing essential diagnostic access to the plasma. Many components will operate close to the first wall, e.g. ceramics and mineral insulated cable for magnetic diagnostics and mirrors for optical diagnostics; these components must be selected and mounted so that they will operate and survive in fluxes which require special material selection. The measurement requirements have been assessed so that the diagnostics for the FIRE device can be defined. Clearly a better set of diagnostics of alpha-particles than that available for TFTR is essential, since the alpha-particles provide the dominant sources of heating and of instability-drive in the plasma

  8. Recent diagnostic developments on LHD

    International Nuclear Information System (INIS)

    Sudo, S.; Nagayama, Y.; Peterson, B.J.

    2003-01-01

    Standard diagnostics for fundamental plasma parameters and for plasma physics are routinely utilized for daily operation and physics study in the large helical device (LHD) with high reliability. Diagnostics for steady state plasma are intensively developed, especially for T e , n e (YAG laser Thomson, CO 2 laser polarimeter), data acquisition in steady state, heat resistant probes. To clarify the plasma property of the helical structure, 2-D or 3-D diagnostics are intensively developed: Tangential cameras (Fast SX TV, Photon counting CCD, H α TV); Tomography (Tangential SX CCD, Bolometer); Imaging (Bolometer, ECE, Reflectometer). Divertor and edge physics are one of important key issues for steady state operation. Diagnostics for neutral flux (H α array, Zeeman spectroscopy) and n e (Fast scanning probe, Li beam probe, Pulsed radar reflectometer). In addition to these, advanced diagnostics are being intensively developed with national and international collaborations in LHD. (author)

  9. An Estimation of Operator's Diagnostic Time for Feed-And-Bleed Operation under Various Scenarios

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bo Gyung; Kang, Hyun Gook [KAIST, Daejeon (Korea, Republic of); Yoon, Ho Joon [Khalifa University of Science, Abu Dhabi (United Arab Emirates)

    2015-10-15

    In order to assess realistic safety of plant, effects of interactions between components, operator, and plant condition are needed to be considered in the PSA model. One of the important issues to estimate the CDF is the estimation of human error probability (HEP). When an accident occurs, operators follow the emergency operating procedure and check various alarm, parameters, and signals. In the conventional Korean PSA model, the Korean standard HRA (K-HRA) method is used. In this method, the HEP is the sum of diagnosis error probability and execution error probability. A diagnosis error probability is expressed by the available time for diagnosis and adjusting performance shaping factors, and an execution error probability is a function of task type and stress level. Available time for diagnosis is very important factor of HEP. If the available time for diagnosis is short, the HEP becomes high. In order to obtain the realistic risk assessment results, we first focus on the estimation of HEP considering the plant dynamics under various scenarios. Target operation and scenarios are feed-and bleed operation (F and B operation) and total loss of feedwater (TLOFW) accident with/without loss of coolant accident (LOCA). One of the highest HEP is HEP of FnB operation. In additional, Scenarios, which are related to combination secondary heat removal failure and primary heat removal failure, are most critical core damage scenario of the combined accident except scenarios related to station black out (SBO). In these scenarios, the FnB operation is last resort to prevent core damage. To estimate available operator diagnosis time, we identify the relationship between accidents, mitigation function, and plant condition. Distribution of available time of diagnosis was estimated using the MOSAIQUE. The variables are break size, break timing, trip timing of RCP, and availability of high pressure safety injection (HPSI) pump under the TLOFW accident with LOCA. For Type 1 accident

  10. Cancer diagnostics: The journey from histomorphology to molecular profiling.

    Science.gov (United States)

    Ahmed, Atif A; Abedalthagafi, Malak

    2016-09-06

    Although histomorphology has made significant advances into the understanding of cancer etiology, classification and pathogenesis, it is sometimes complicated by morphologic ambiguities, and other shortcomings that necessitate the development of ancillary tests to complement its diagnostic value. A new approach to cancer patient management consists of targeting specific molecules or gene mutations in the cancer genome by inhibitory therapy. Molecular diagnostic tests and genomic profiling methods are increasingly being developed to identify tumor targeted molecular profile that is the basis of targeted therapy. Novel targeted therapy has revolutionized the treatment of gastrointestinal stromal tumor, renal cell carcinoma and other cancers that were previously difficult to treat with standard chemotherapy. In this review, we discuss the role of histomorphology in cancer diagnosis and management and the rising role of molecular profiling in targeted therapy. Molecular profiling in certain diagnostic and therapeutic difficulties may provide a practical and useful complement to histomorphology and opens new avenues for targeted therapy and alternative methods of cancer patient management.

  11. A Diagnostics Tool to detect ensemble forecast system anomaly and guide operational decisions

    Science.gov (United States)

    Park, G. H.; Srivastava, A.; Shrestha, E.; Thiemann, M.; Day, G. N.; Draijer, S.

    2017-12-01

    The hydrologic community is moving toward using ensemble forecasts to take uncertainty into account during the decision-making process. The New York City Department of Environmental Protection (DEP) implements several types of ensemble forecasts in their decision-making process: ensemble products for a statistical model (Hirsch and enhanced Hirsch); the National Weather Service (NWS) Advanced Hydrologic Prediction Service (AHPS) forecasts based on the classical Ensemble Streamflow Prediction (ESP) technique; and the new NWS Hydrologic Ensemble Forecasting Service (HEFS) forecasts. To remove structural error and apply the forecasts to additional forecast points, the DEP post processes both the AHPS and the HEFS forecasts. These ensemble forecasts provide mass quantities of complex data, and drawing conclusions from these forecasts is time-consuming and difficult. The complexity of these forecasts also makes it difficult to identify system failures resulting from poor data, missing forecasts, and server breakdowns. To address these issues, we developed a diagnostic tool that summarizes ensemble forecasts and provides additional information such as historical forecast statistics, forecast skill, and model forcing statistics. This additional information highlights the key information that enables operators to evaluate the forecast in real-time, dynamically interact with the data, and review additional statistics, if needed, to make better decisions. We used Bokeh, a Python interactive visualization library, and a multi-database management system to create this interactive tool. This tool compiles and stores data into HTML pages that allows operators to readily analyze the data with built-in user interaction features. This paper will present a brief description of the ensemble forecasts, forecast verification results, and the intended applications for the diagnostic tool.

  12. Preliminary evaluation of operational parameters in fixed x-ray diagnostics equipment

    International Nuclear Information System (INIS)

    Bacelar, Alexandre; Oliveira, Sandro Soletti de; Streck, Elaine E.; Furtado, Alvaro Porto Alegre; Pinto, Ana Lucia Acosta

    1998-01-01

    In this work they were appraised 22 fixed X-ray diagnostic equipment belonging to three great medical institutions in Porto Alegre - RS, Brazil, with the purpose of demonstrating the importance of the implementation of a Quality Warranty program, advised by a health physicist, in the performance of these equipment. For so some data of alignment and collimation of the beam, peak tube voltage, tube current, transportable charge and exposition time were collected. The results of the tests showed that in only one of the institutions all the equipment remained in operationally acceptable conditions, with relative percent errors below 10%, concerning to the analyzed parameters. This study also showed that the performance of the equipment of the three analyzed institutions is a direct reflex of the maintenance of a Quality Warranty Program, advised by a qualified professional. (author)

  13. Diagnostic Strategy in APR1400

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dongyoung; Kim, Jonghyun [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of)

    2013-05-15

    These features may bring out changes in operator tasks, changing the characteristics of tasks, or creating new tasks. Diagnostic strategy for identifying anomaly may be different especially in APR1400 from that in the analog control room due to the change of human-system interface, i.e. alarm system and display system. Since the first plant of APR1400 is being built at this moment, it is not known what strategies the operators will adopt in diagnosis tasks in the new operating environment. In this light, this paper aims at investigating operator's diagnostic strategies which are appropriate for APR1400. In order to collect data, several different approaches which are complementary are used to identify diagnostic strategies in the digital control room: analysis on audio/video recording of operation, observation in the simulator, and interview with the operators. The result shows that the digital control room introduces new strategies in the diagnosis, compared with the analog control room, and also changed the characteristics of strategies, mostly, by getting more support from the computerized system. This paper investigated how the digitalized control room may influence operator's diagnostic strategies. Several different approaches, i. e., audio/video record, observation of training, and the interview with operators, were used to gather information about the operator's behaviors. As a conclusion, this paper figured out that the digital control room introduces new strategies in the diagnosis, compared with the analog control room, and also changed the characteristics of the strategies, mostly, by getting more support from the computerized system. The operators interviewed also commented that the diagnosis in the APR1400 is quicker, more correct, and easier, compared with the analog control room.

  14. Category-based attentional guidance can operate in parallel for multiple target objects.

    Science.gov (United States)

    Jenkins, Michael; Grubert, Anna; Eimer, Martin

    2018-04-30

    The question whether the control of attention during visual search is always feature-based or can also be based on the category of objects remains unresolved. Here, we employed the N2pc component as an on-line marker for target selection processes to compare the efficiency of feature-based and category-based attentional guidance. Two successive displays containing pairs of real-world objects (line drawings of kitchen or clothing items) were separated by a 10 ms SOA. In Experiment 1, target objects were defined by their category. In Experiment 2, one specific visual object served as target (exemplar-based search). On different trials, targets appeared either in one or in both displays, and participants had to report the number of targets (one or two). Target N2pc components were larger and emerged earlier during exemplar-based search than during category-based search, demonstrating the superior efficiency of feature-based attentional guidance. On trials where target objects appeared in both displays, both targets elicited N2pc components that overlapped in time, suggesting that attention was allocated in parallel to these target objects. Critically, this was the case not only in the exemplar-based task, but also when targets were defined by their category. These results demonstrate that attention can be guided by object categories, and that this type of category-based attentional control can operate concurrently for multiple target objects. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Operational Benefits of Meeting California's Energy Storage Targets

    Energy Technology Data Exchange (ETDEWEB)

    Eichman, Josh; Denholm, Paul; Jorgenson, Jennie; Helman, Udi

    2016-05-01

    In October 2013, the California Public Utilities Commission (CPUC) finalized procurement targets and other requirements to its jurisdictional utilities for a minimum of 1,325 MW of 'viable and cost-effective' energy storage systems by 2020. The goal of this study is to explore several aspects of grid operations in California and the Western Interconnection resulting from meeting the CPUC storage targets. We perform this analysis using a set of databases and grid simulation tools developed and implemented by the CPUC, the California Independent System Operator (CAISO), and the California Energy Commission (CEC) for the CPUC's Long-term Procurement Plan (LTPP). The 2014 version of this database contains information about generators, storage, transmission, and electrical demand, for California in the year 2024 for both 33 percent and 40 percent renewable energy portfolios. We examine the value of various services provided by energy storage in these scenarios. Sensitivities were performed relating to the services energy storage can provide, the capacity and duration of storage devices, export limitations, and negative price floor variations. Results show that a storage portfolio, as outlined by the CPUC, can reduce curtailment and system-wide production costs for 33 percent and 40 percent renewable scenarios.

  16. Automated diagnostics scoping study. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Quadrel, R.W.; Lash, T.A.

    1994-06-01

    The objective of the Automated Diagnostics Scoping Study was to investigate the needs for diagnostics in building operation and to examine some of the current technologies in automated diagnostics that can address these needs. The study was conducted in two parts. In the needs analysis, the authors interviewed facility managers and engineers at five building sites. In the technology survey, they collected published information on automated diagnostic technologies in commercial and military applications as well as on technologies currently under research. The following describe key areas that the authors identify for the research, development, and deployment of automated diagnostic technologies: tools and techniques to aid diagnosis during building commissioning, especially those that address issues arising from integrating building systems and diagnosing multiple simultaneous faults; technologies to aid diagnosis for systems and components that are unmonitored or unalarmed; automated capabilities to assist cause-and-effect exploration during diagnosis; inexpensive, reliable sensors, especially those that expand the current range of sensory input; technologies that aid predictive diagnosis through trend analysis; integration of simulation and optimization tools with building automation systems to optimize control strategies and energy performance; integration of diagnostic, control, and preventive maintenance technologies. By relating existing technologies to perceived and actual needs, the authors reached some conclusions about the opportunities for automated diagnostics in building operation. Some of a building operator`s needs can be satisfied by off-the-shelf hardware and software. Other needs are not so easily satisfied, suggesting directions for future research. Their conclusions and suggestions are offered in the final section of this study.

  17. Targeted radionuclide therapy

    African Journals Online (AJOL)

    target for which a speci c treatment/drug is intended (Fig. 1). eranostics .... Using an anti-CD20 antibody as a delivery device to target the follicular ... systems combine diagnostic imaging (Ga-68-DOTATATE PET/CT) .... Intra-articular injected ...

  18. Some aspects of diagnostic systems perspective

    International Nuclear Information System (INIS)

    Korosec, D.

    1998-01-01

    The integrity and safety of all nuclear power plant systems and components is guaranteed by the high requirements to quality assurance during all phases of design, fabrication, construction and operation. Many of the countries operating nuclear facilities, introduced advanced, sophisticated diagnostic systems for continuous monitoring safety important process parameters. The licensee should perform an assessment of the existing diagnostic systems, often supplied by the original design, their reliability and the need for the introduction of the additional monitoring/diagnostic systems. The operating experience should be taken into account and the assessment of the further needs. On this field has to be made on the results of PSA studies. In addition to the cost benefit analysis the evaluation of the new diagnostic systems in the light of nuclear safety should be also made. Experience, gained from the utilities, which have already installed this kind of the equipment should be very useful. Introducing new diagnostic systems will require often a safety assessment of the necessary modifications. Licensing process should be based on the existing nuclear legislation with certain additional requirements. (author)

  19. Recent diagnostic developments on LHD

    International Nuclear Information System (INIS)

    Sudo, S; Ozaki, T; Ashikawa, N; Emoto, M; Goto, M; Hamada, Y; Ida, K; Ido, T; Iguchi, H; Inagaki, S; Isobe, M; Kawahata, K; Khlopenkov, K; Kobuchi, T; Liang, Y; Masuzaki, S; Minami, T; Morita, S; Muto, S; Nagayama, Y; Nakanishi, H; Narihara, K; Nishizawa, A; Ohdachi, S; Osakabe, M; Peterson, B J; Sakakibara, S; Sasao, M; Sato, K; Shoji, M; Tamura, N; Tanaka, K; Toi, K; Tokuzawa, T; Watanabe, K; Watanabe, T; Yamada, I; Goncharov, P; Ejiri, A; Okajima, S; Mase, A; Tsuji-Iio, S; Akiyama, T; Lyon, J F; Vyacheslavov, L N; Sanin, A

    2003-01-01

    The recent diagnostic developments on the large helical device (LHD) are described briefly. LHD is the largest helical machine with all superconducting coils, and its purpose is to prove the ability of a helical system to confine a fusion-relevant plasma in steady state. According to the missions of LHD research, the diagnostic devices are categorized as follows: diagnostics for (i) high nτ E T plasmas and transport physics; (ii) magnetohydrodynamic stability; (iii) long pulse operation and divertor function; and (iv) energetic particles. These are briefly described focusing on the recent developments of the devices. Since the LHD experiment started in March 1998, five series of experimental campaigns have been carried out. The LHD diagnostics during these periods were operated successfully, and contributed to the analysis of the experimental results

  20. Operational limit of a planar DC magnetron cluster source due to target erosion

    International Nuclear Information System (INIS)

    Rai, A.; Mutzke, A.; Bandelow, G.; Schneider, R.; Ganeva, M.; Pipa, A.V.; Hippler, R.

    2013-01-01

    The binary collision-based two dimensional SDTrimSP-2D model has been used to simulate the erosion process of a Cu target and its influence on the operational limit of a planar DC magnetron nanocluster source. The density of free metal atoms in the aggregation region influences the cluster formation and cluster intensity during the target lifetime. The density of the free metal atoms in the aggregation region can only be predicted by taking into account (i) the angular distribution of the sputtered flux from the primary target source and (ii) relative downwards shift of the primary source of sputtered atoms during the erosion process. It is shown that the flux of the sputtered atoms smoothly decreases with the target erosion

  1. In-service diagnostics of pumping facilities

    International Nuclear Information System (INIS)

    Jaros, I.

    1987-01-01

    The potential is discussed of technical diagnostics in increasing operating reliability of pumping facilities of conventional and nuclear power plants, and in rationalizing the system of their maintenance. Attention is focused on the selection of diagnostic parameters in which the so-called subjective expert methodology is applied, and on the diagnostic system design. At this stage, the construction of the respective facility and the analysis of the failure rate of its individual assemblies should be considered. The selection of diagnostic means directly depends on the selection of diagnostic parameters and is conditional on other factors, such as availability, cost, technical service, and operator's training. Briefly characterized are Czechoslovak standards assessing the mechanical condition of rotary machines from the measurement of the effective value of the rate of their oscillations. (Z.M.)

  2. Molecular diagnostics of periodontitis

    OpenAIRE

    Izabela Korona-Głowniak; Radosław Siwiec; Marcin Berger; Anna Malm; Jolanta Szymańska

    2017-01-01

    The microorganisms that form dental plaque are the main cause of periodontitis. Their identification and the understanding of the complex relationships and interactions that involve these microorganisms, environmental factors and the host’s health status enable improvement in diagnostics and targeted therapy in patients with periodontitis. To this end, molecular diagnostics techniques (both techniques based on the polymerase chain reaction and those involving nucleic acid analysis via hybridi...

  3. Development of new diagnostics for WEST

    International Nuclear Information System (INIS)

    Lotte, P.; Moreau, P.; Gil, C.

    2015-01-01

    WEST, the upgraded superconducting tokamak Tore Supra, will be an international experimental platform aimed to support ITER Physics program. The main objective of WEST is to provide relevant plasma conditions for validating plasma facing component (PFC) technology, in particular the actively cooled Tungsten divertor monoblocks, and also assessing high heat flux and high fluence plasma wall interactions with Tungsten in order to prepare ITER divertor operation. In parallel, WEST will also open new experimental opportunities for developing integrated H mode operation and exploring steady state scenarios in a metallic environment. In order to fulfil the Scientific Program of WEST, new diagnostics have been developed in addition to the already existing diagnostics of Tore Supra, modified and improved during the shutdown. For the PFC technology validation program, new tools have been implemented, like a full infrared survey of the PFC, a new calorimetry system, local temperature measurements (thermocouple and Bragg grating optical fiber), and several sets of Langmuir probes. For the analysis of long pulse H mode operation, new plasma diagnostics will be implemented, among which the Visible Spectroscopy diagnostic for W sources and transport studies, the Soft-Xray diagnostic based on gas electron multiplier detectors for transport and MHD studies, the X-ray imaging crystal spectroscopy diagnostic with advanced solid state detector properties for ion temperature, ion density and plasma rotation velocity measurements, and the ECE Imaging diagnostic for MHD and turbulence studies. Most of these new diagnostics are developed with the participation of French Universities or through international collaborations. This paper focuses on the description of these four plasma diagnostics. (author)

  4. Operative and diagnostic hysteroscopy: A novel learning model combining new animal models and virtual reality simulation.

    Science.gov (United States)

    Bassil, Alfred; Rubod, Chrystèle; Borghesi, Yves; Kerbage, Yohan; Schreiber, Elie Servan; Azaïs, Henri; Garabedian, Charles

    2017-04-01

    Hysteroscopy is one of the most common gynaecological procedure. Training for diagnostic and operative hysteroscopy can be achieved through numerous previously described models like animal models or virtual reality simulation. We present our novel combined model associating virtual reality and bovine uteruses and bladders. End year residents in obstetrics and gynaecology attended a full day workshop. The workshop was divided in theoretical courses from senior surgeons and hands-on training in operative hysteroscopy and virtual reality Essure ® procedures using the EssureSim™ and Pelvicsim™ simulators with multiple scenarios. Theoretical and operative knowledge was evaluated before and after the workshop and General Points Averages (GPAs) were calculated and compared using a Student's T test. GPAs were significantly higher after the workshop was completed. The biggest difference was observed in operative knowledge (0,28 GPA before workshop versus 0,55 after workshop, pvirtual reality simulation is an efficient model not described before. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Diagnostic radiopharmaceuticals for localization in target tissues exhibiting a regional pH shift relative to surrounding tissues

    International Nuclear Information System (INIS)

    Blau, M.; Kung, H.F.

    1985-01-01

    Diagnostic radiopharmaceutical compounds are provided which are capable of entering a target tissue or a target organ by passive diffusion through cell walls and which are effectively accumulated and retained within the target tissue or organ due to a regional pH shift. Such compounds are desirably readily accessible synthetically using readily available radionuclides. The compound comprises a radioactive isotope of an element in chemical combination with at least one amine group and preferably with at least two secondary or tertiary amine groups. The radioactive element is an element other than iodine emitting gamma ray, x-ray or positron radiation. When the element is a gamma ray emitting isotope, at least 75 percent of the number of emissions is emitted at energies of between 80 and 400 keV. The half-life of the isotope is usually between two minutes and 15 days. The compound has acid-base characteristics such that the state of ionization of the compound at the pH of the body is significantly different and usually less than its state of ionization at the intracellular pH of the target tissue. The compound has such lipid solubility characteristics that it is capable of ready penetration through cell walls, but within cells its lipid solubility is substantially decreased, whereby the ability of the compound to leave the target tissue is substantially diminished. Specific data relevant to di-beta-(piperidinoethyl)-selenide and di-beta-(morpholinoethyl)-selenide in rat brains are presented

  6. Studies of implosion dynamics of D3He gas-filled plastic targets using nuclear diagnostics at OMEGA

    International Nuclear Information System (INIS)

    Falk, Magnus

    2004-09-01

    Information about target-implosion dynamics is essential for understanding how assembly occurs. Without carefully tailored assembly of the fuel, hot-spot ignition on National Ignition Facility (NIF) will fail. Hot spot ignition relies on shock convergence to 'ignite' the hot spot (shock burn), followed by propagation of the burn into the compressed shell material (compressive burn). The relationship between these events must be understood to ensure the success of Inertial Confinement Fusion (ICF) ignition. To further improve our knowledge about the timing of these events, temporal evolution of areal density (density times radius, normally referred to as ρR) and burn of direct-drive, D 3 He gas-filled plastic target implosions have been studied using dd neutrons and d 3 He protons. The proton temporal diagnostic (PTD) code was developed for this purpose. ρR asymmetries were observed at shock-bang time (time of peak burn during shock phase) and grew approximately twice as fast as the average ρR, without any phase changes. Furthermore, it was observed that the shock-bang and compression-bang time occur earlier, and that the time difference between these events decreases for higher laser energy on target, which indicates that the compression-bang time is more sensitive to the variation of laser energy on target. It was also observed that the duration of shock and compression phase might decrease for higher laser energy on target

  7. Simultaneous detection of five different DNA targets by real-time Taqman PCR using the Roche LightCycler480: Application in viral molecular diagnostics

    NARCIS (Netherlands)

    Molenkamp, Richard; van der Ham, Alwin; Schinkel, Janke; Beld, Marcel

    2007-01-01

    One of the most interesting aspects of real-time PCR based on the detection of fluorophoric labeled oligonucleotides is the possibility of being able to detect conveniently multiple targets in the same PCR reaction. Recently, Roche Diagnostics launched a real-time PCR platform, the LightCycler480

  8. A management system of data for department of diagnostic radiology and patients using the personal computer

    International Nuclear Information System (INIS)

    Kim, Jin Hee; Park, Tae Joon; Choi, Tae Haing; Lim, Se Hwan; Joon Yang Noh; Kim, Sung Jin

    1996-01-01

    With the use of personal computers generalized, departmental society leveled computerization is going on in some other departments. So we tried to develop a program having a simple user interface, various retrieval functions and, analytic and statistic process system to effectively help patient care suitable for works concerned with department of diagnostic radiology and works of department. This program deals with such target works as department of diagnostic radiology and some works to need a lot of bookkeeping. It is deviced to operate with Windows (Microsoft, America), and central processing unit(486DX-2), memory unit(8 Mbyte). As a developmental tool, Foxpro 2.6 for windows R (Microsoft, America). This program can be easily accessed even by staffs poor at computer and it can make many books recording various check-ups and operations unnecessary, which were difficult to keep. Besides, it can keep data as a unified form, and so it provides patient care and other works with convenience and helps applying those stored data scientific research. The above result shows that works of department can be effectively controlled by analyzing or printing various check-up and operation done by department of diagnostic radiology

  9. European DEMO divertor target: Operational requirements and material-design interface

    Directory of Open Access Journals (Sweden)

    J.H. You

    2016-12-01

    Full Text Available Recently, an integrated program of conceptual design activities for the European DEMO reactor was launched in the framework of the EUROfusion Consortium, where reliable power handling capability was identified as one of the most critical scientific as well as technological challenges for a DEMO reactor. The divertor is the key in-vessel plasma-facing component being in charge of power exhaust and removal of impurity particles. The DEMO divertor target will have to withstand extreme thermal loads where the local peak heat flux is expected to reach up to 20 MW/m2 during slow transient events in DEMO. To assure sufficient heat removal capability of the divertor target against normal and transient operational scenarios under expected cumulative neutron dose of up to 13 dpa is one of the fundamental engineering challenges imposed on target design. To develop the design of the DEMO divertor and related technologies, an R&D work package ‘Divertor’ has been set up in this consortium. The subproject ‘Target Development’ is devoted to the development of the conceptual design and the core technologies of the plasma-facing target. Devising and implementing novel structural heat sink materials (e.g. W/Cu composites to advanced target design concepts is one of the major objectives of this subproject. In this paper, the underlying design requirements imposed by the envisaged power exhaust goal and the prominent material-design interface issues are discussed. In addition, the candidate design concepts being currently considered are presented together with the related material issues. Finally, the first results achieved so far are presented.

  10. Study of methodology diversification in diagnostics

    International Nuclear Information System (INIS)

    Suda, Kazunori; Yonekawa, Tsuyoshi; Yoshikawa, Shinji; Hasegawa, Makoto

    1999-03-01

    There are several research activities to enhance safety and reliability of nuclear power plant operation and maintenance. We are developing a concept of an autonomous operation system where the role of operators is replaced with artificial intelligence. The purpose of the study described in this report is to develop a operator support system in abnormal plant situations. Conventionally, diagnostic modules based on individual methodology such as expert system have been developed and verified. In this report, methodology diversification is considered to integrate diagnostic modules which performance are confirmed using information processing technique. Technical issues to be considered in diagnostic methodology diversification are; 1)reliability of input data, 2)diversification of knowledge models, algorithms and reasoning schemes, 3)mutual complement and robustness. The diagnostic module utilizing the different approaches defined along with strategy of diversification was evaluated using fast breeder plant simulator. As a result, we confirmed that any singular diagnostic module can not meet accuracy criteria for the entire set of anomaly events. In contrast with this, we confirmed that every abnormality could be precisely diagnosed by a mutual combination. In other words, legitimacy of approach selected by strategy of diversification was shown, and methodology diversification attained clear efficiency for abnormal diagnosis. It has been also confirmed that the diversified diagnostic system implemented in this study is able to maintain its accuracy even in case that encountered scale of abnormality is different from reference cases embedded in the knowledge base. (author)

  11. Diagnostics for the National Compact Stellarator Experiment

    International Nuclear Information System (INIS)

    Stratton, B.C.; Johnson, D.; Feder, R.; Fredrickson, E.; Neilson, H.; Takahashi, H.; Zarnstorf, M.; Cole, M.; Goranson, P.; Lazarus, E.; Nelson, B.

    2003-01-01

    The status of planning of the National Compact Stellarator Experiment (NCSX) diagnostics is presented, with the emphasis on resolution of diagnostics access issues and on diagnostics required for the early phases of operation

  12. Comprehensive diagnostic set for intense lithium ion hohlraum experiments on PBFA II

    International Nuclear Information System (INIS)

    Leeper, R.J.; Bailey, J.E.; Carlson, A.L.

    1994-01-01

    A review of the comprehensive diagnostic package developed at Sandia National Laboratories for intense lithium ion hohlraum target experiments on PBFA II will be presented. This package contains an extensive suite of x-ray spectral and imaging diagnostics that enable measurements of target radiation smoothing, hydro-motion, and temperature. The x-ray diagnostics include time-integrated and time-resolved pinhole cameras, energy-resolved 1-D streaked imaging diagnostics that enable measurements of target radiation smoothing, hydro-motion, and temperature. The x-ray diagnostics include time-integrated and time-resolved pinhole cameras, energy-resolved 1-D streaked imaging diagnostics, time-integrated and time-resolved grazing incidence spectrographs, a transmission grating spectrography, an elliptical crystal spectrograph, a bolometer array, an eleven element x-ray diode (XRD) array, and an eleven element PIN diode detector array. A hohlraum temperature measurement technique under development is a shock breakout diagnostic that measures the radiation pressure at the hohlraum wall. The incident Li beam symmetry and an estimate of incident Li beam power density are measured from ion beam-induced characteristic x-ray line and neutron emissions. An attempt to measure the Li beam intensity directly on target used Rutherford scattered ions into an ion movie camera and a magnetic spectrograph. The philosophy used in designing all the diagnostics in the set has emphasized redundant and independent measurements of fundamental physical quantities relevant to the performance of the target. Details of each diagnostic, its integration, data reduction procedures, and recent PBFA-II data will be discussed

  13. Utilization of diagnostic ultrasound and intravenous lipid-encapsulated perfluorocarbons in non-invasive targeted cardiovascular therapeutics.

    Science.gov (United States)

    Porter, Thomas R; Choudhury, Songita A; Xie, Feng

    2016-01-01

    Diagnostic ultrasound (DUS) pressures have the ability to induce inertial cavitation (IC) of systemically administered microbubbles; this bioeffect has many diagnostic and therapeutic implications in cardiovascular care. Diagnostically, commercially available lipid-encapsulated perfluorocarbons (LEP) can be utilized to improve endocardial and vascular border delineation as well as assess myocardial perfusion. Therapeutically, the liquid jets induced by IC can alter endothelial function and dissolve thrombi within the immediate vicinity of the cavitating microbubbles. The cavitating LEP can also result in the localized release of any bound therapeutic substance at the site of insonation. DUS-induced IC has been tested in pre-clinical studies to determine what effect it has on acute vascular and microvascular thrombosis as well as nitric oxide (NO) release. These pre-clinical studies have consistently shown that DUS-induced IC of LEP is effective in restoring coronary vascular and microvascular flow in acute ST segment elevation myocardial infarction (STEMI), with microvascular flow improving even if upstream large vessel flow has not been achieved. The initial clinical trials examining the efficacy of short pulse duration DUS high mechanical index impulses in patients with STEMI are underway, and preliminary studies have suggested that earlier epicardial vessel recanalization can be achieved prior to arriving in the cardiac catheterization laboratory. DUS high mechanical index impulses have also been effective in pre-clinical studies for targeting DNA delivery that has restored islet cell function in type I diabetes and restored vascular flow in the extremities downstream from a peripheral vascular occlusion. Improvements in this technique will come from three dimensional arrays for therapeutic applications, more automated delivery techniques that can be applied in the field, and use of submicron-sized acoustically activated LEP droplets that may better permeate the

  14. First operations with the new Collective Thomson Scattering diagnostic on the Frascati Tokamak Upgrade device

    Science.gov (United States)

    Bin, W.; Bruschi, A.; D'Arcangelo, O.; Castaldo, C.; De Angeli, M.; Figini, L.; Galperti, C.; Garavaglia, S.; Granucci, G.; Grosso, G.; Korsholm, S. B.; Lontano, M.; Mellera, V.; Minelli, D.; Moro, A.; Nardone, A.; Nielsen, S. K.; Rasmussen, J.; Simonetto, A.; Stejner, M.; Tartari, U.

    2015-10-01

    Anomalous emissions were found over the last few years in spectra of Collective Thomson Scattering (CTS) diagnostics in tokamak devices such as TEXTOR, ASDEX and FTU, in addition to real CTS signals. The signal frequency, down-shifted with respect to the probing one, suggested a possible origin in Parametric Decay Instability (PDI) processes correlated with the presence of magnetic islands and occurring for pumping wave power levels well below the threshold predicted by conventional models. A threshold below or close to the Electron Cyclotron Resonance Heating (ECRH) power levels could limit, under certain circumstances, the use of the ECRH in fusion devices. An accurate characterization of the conditions for the occurrence of this phenomenon and of its consequences is thus of primary importance. Exploiting the front-steering configuration available with the real-time launcher, the implementation of a new CTS setup now allows studying these anomalous emission phenomena in FTU under conditions of density and wave injection geometry that are more similar to those envisaged for CTS in ITER. The upgrades of the diagnostic are presented as well as a few preliminary spectra detected with the new system during the very first operations in 2014. The present work has been carried out under an EUROfusion Enabling Research project. A shorter version of this contribution is due to be published in PoS at: 1st EPS conference on Plasma Diagnostics

  15. THE SIMULATION DIAGNOSTIC METHODS AND REGENERATION WAYS OF REINFORCED - CONCRETE CONSTRUCTIONS OF BRIDGES IN PROVIDING THEIR OPERATING RELIABILITY AND LONGEVITY

    OpenAIRE

    B. V. Savchinskiy

    2010-01-01

    On the basis of analysis of existing diagnostic methods and regeneration ways of reinforced-concrete constructions of bridges the recommendations on introduction of new modern technologies of renewal of reinforced-concrete constructions of bridges in providing their operating reliability and longevity are offered.

  16. A Primer on Receiver Operating Characteristic Analysis and Diagnostic Efficiency Statistics for Pediatric Psychology: We Are Ready to ROC

    Science.gov (United States)

    2014-01-01

    Objective To offer a practical demonstration of receiver operating characteristic (ROC) analyses, diagnostic efficiency statistics, and their application to clinical decision making using a popular parent checklist to assess for potential mood disorder. Method Secondary analyses of data from 589 families seeking outpatient mental health services, completing the Child Behavior Checklist and semi-structured diagnostic interviews. Results Internalizing Problems raw scores discriminated mood disorders significantly better than did age- and gender-normed T scores, or an Affective Problems score. Internalizing scores 30 had a diagnostic likelihood ratio of 7.4. Conclusions This study illustrates a series of steps in defining a clinical problem, operationalizing it, selecting a valid study design, and using ROC analyses to generate statistics that support clinical decisions. The ROC framework offers important advantages for clinical interpretation. Appendices include sample scripts using SPSS and R to check assumptions and conduct ROC analyses. PMID:23965298

  17. Review of laser mega joule target area: Design and processes

    International Nuclear Information System (INIS)

    Geitzholz, M.; Lanternier, C.

    2006-01-01

    The Laser Mega Joule (LMJ) target area is currently designed to achieve ignition and significant fusion gain in laboratory. LMJ will be composed of 240 identical large 370 mm * 370 mm square laser beams. These beams will focus 2 mega-joules of energy at the wavelength of 351 nm on the center of an experiment chamber. Design studies for target equipment are well advanced, target chamber and target holder (concrete) works have already begun. A detailed overview of the target area equipment is presented: target chamber, frame, diagnostic inserter manipulator, final optic assembly, dual diagnostic and laser reference, non cryogenic target positioner. Recent technical and architectural choices are detailed including safety transfers and alignment processes (target, laser and diagnostic). All this target equipment allows us to optimize shot chrono-gram, from target metrology to the shot, including calibration process. (authors)

  18. Studying the effects of operators' problem solving behaviour when using a diagnostic expert system developed for the nuclear industry

    International Nuclear Information System (INIS)

    Holmstroem, C.B.O.; Volden, F.S.; Endestad, T.

    1992-01-01

    This paper describes an experiment with the purpose to also illustrate and discuss some of the methodological problems when empirically studying problem solving. The experiment which was the second in a series, conducted at the OECD Halden Reactor Project, aimed to assess the effect on nuclear power plant operators diagnostic behaviour when using a rule-based diagnostic expert system. The rule-based expert system used in the experiment is called DISKET (Diagnosis System Using Knowledge Engineering Technique) and was originally developed by the Japan Atomic Energy Research Institute (JAERI). The experiment was performed in the Halden man-machine laboratory using a full scope pressurized water reactor simulator. Existing data collection methods and experimental design principles includes possibilities but also limitations. This is discussed and experiences are presented. Operator performance in terms of quality of diagnosis is improved by the use of DISKET. The use of the DISKET system also influences operators problem solving behaviour. The main difference between the two experimental conditions can be characterized as while the DISKET users during the diagnosis process are following a strategy which is direct and narrowed, the non-DISKET users are using a much broader and less focused search when trying to diagnose a disturbance. (author)

  19. Inherited and Acquired Muscle Weakness: A Moving Target for Diagnostic Muscle Biopsy.

    Science.gov (United States)

    Stenzel, Werner; Schoser, Benedikt

    2017-08-01

    Inherited and acquired muscular weakness is caused by multiple conditions. While the inherited ones are mostly caused by mutations in genes coding for myopathic or neurogenic diseases, the acquired ones occur due to inflammatory, endocrine, or toxic etiologies. Precise diagnosis of a specific disease may be challenging and may require a multidisciplinary approach. What is the current place for a diagnostic biopsy of skeletal muscle? Diagnostic muscle biopsy lost in this context its first-tier place in the primary diagnostic workup for some diseases, but it is still mandatory for others. We here summarize conditions in which we believe a diagnostic sample is most relevant and mention those in which a biopsy may be secondary or can even be left out. We would like to stress that muscle biopsy nowadays has a new important place in description and definition of new diseases, for example, discovered by modern genetic approaches. Georg Thieme Verlag KG Stuttgart, New York.

  20. Efficient production and diagnostics of MeV proton beams from a cryogenic hydrogen ribbon

    International Nuclear Information System (INIS)

    Velyhan, A.; Giuffrida, L.; Scuderi, V.; Lastovicka, T.; Margarone, D.; Perin, J.P.; Chatain, D.; Garcia, S.; Bonnay, P.; Dostal, J.; Ullschmied, J.; Dudzak, R.; Krousky, E.; Cykhardt, J.; Prokupek, J.; Pfeifer, M.; Rosinski, M.; Krasa, J.; Brabcova, K.; Napoli, M. De

    2017-01-01

    A solid hydrogen thin ribbon, produced by the cryogenic system ELISE (Experiments on Laser Interaction with Solid hydrogEn) target delivery system, was experimentally used at the PALS kJ-laser facility to generate intense proton beams with energies in the MeV range. This sophisticated target system operating at cryogenic temperature (∼ 10 K) continuously producing a 62 μm thick target was combined with a 600 J sub-nanosecond laser pulse to generate a collimated proton stream. The accelerated proton beams were fully characterized by a number of diagnostics. High conversion efficiency of laser to energetic protons is of great interest for future potential applications in non-conventional proton therapy and fast ignition for inertial confinement fusion.

  1. Studies of implosion dynamics of D{sup 3}He gas-filled plastic targets using nuclear diagnostics at OMEGA

    Energy Technology Data Exchange (ETDEWEB)

    Falk, Magnus

    2004-09-01

    Information about target-implosion dynamics is essential for understanding how assembly occurs. Without carefully tailored assembly of the fuel, hot-spot ignition on National Ignition Facility (NIF) will fail. Hot spot ignition relies on shock convergence to 'ignite' the hot spot (shock burn), followed by propagation of the burn into the compressed shell material (compressive burn). The relationship between these events must be understood to ensure the success of Inertial Confinement Fusion (ICF) ignition. To further improve our knowledge about the timing of these events, temporal evolution of areal density (density times radius, normally referred to as {rho}R) and burn of direct-drive, D{sup 3}He gas-filled plastic target implosions have been studied using dd neutrons and d{sup 3}He protons. The proton temporal diagnostic (PTD) code was developed for this purpose. {rho}R asymmetries were observed at shock-bang time (time of peak burn during shock phase) and grew approximately twice as fast as the average {rho}R, without any phase changes. Furthermore, it was observed that the shock-bang and compression-bang time occur earlier, and that the time difference between these events decreases for higher laser energy on target, which indicates that the compression-bang time is more sensitive to the variation of laser energy on target. It was also observed that the duration of shock and compression phase might decrease for higher laser energy on target.

  2. Instrumentation for localized superconducting cavity diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Conway, Z. A. [Argonne National Lab. (ANL), Argonne, IL (United States). Physics Division; Ge, M. [Cornell Lab. for Accelerator-Based Sciences and Education, Ithaca, NY (United States); Iwashita, Y. [Kyoto Univ. (Japan)

    2017-01-12

    Superconducting accelerator cavities are now routinely operated at levels approaching the theoretical limit of niobium. To achieve these operating levels more information than is available from the RF excitation signal is required to characterize and determine fixes for the sources of performance limitations. This information is obtained using diagnostic techniques which complement the analysis of the RF signal. In this paper we describe the operation and select results from three of these diagnostic techniques: the use of large scale thermometer arrays, second sound wave defect location and high precision cavity imaging with the Kyoto camera.

  3. Development of a majority vote decision module for a self-diagnostic monitoring system for an air-operated valve system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Woo Shin [Dept. of Information and Communication Engineering, Sejong University, Seoul (Korea, Republic of); Chai, Jang Bom [Dept. of Mechanical Engineering, Ajou University, Suwon (Korea, Republic of); Kim, In Taek [Dept. of Information and Communication Engineering, Myongji University, Yongin (Korea, Republic of)

    2015-08-15

    A self-diagnostic monitoring system is a system that has the ability to measure various physical quantities such as temperature, pressure, or acceleration from sensors scattered over a mechanical system such as a power plant, in order to monitor its various states, and to make a decision about its health status. We have developed a self-diagnostic monitoring system for an air-operated valve system to be used in a nuclear power plant. In this study, we have tried to improve the self-diagnostic monitoring system to increase its reliability. We have implemented three different machine learning algorithms, i.e., logistic regression, an artificial neural network, and a support vector machine. After each algorithm performs the decision process independently, the decision-making module collects these individual decisions and makes a final decision using a majority vote scheme. With this, we performed some simulations and presented some of its results. The contribution of this study is that, by employing more robust and stable algorithms, each of the algorithms performs the recognition task more accurately. Moreover, by integrating these results and employing the majority vote scheme, we can make a definite decision, which makes the self-diagnostic monitoring system more reliable.

  4. Development of a majority vote decision module for a self-diagnostic monitoring system for an air-operated valve system

    International Nuclear Information System (INIS)

    Kim, Woo Shin; Chai, Jang Bom; Kim, In Taek

    2015-01-01

    A self-diagnostic monitoring system is a system that has the ability to measure various physical quantities such as temperature, pressure, or acceleration from sensors scattered over a mechanical system such as a power plant, in order to monitor its various states, and to make a decision about its health status. We have developed a self-diagnostic monitoring system for an air-operated valve system to be used in a nuclear power plant. In this study, we have tried to improve the self-diagnostic monitoring system to increase its reliability. We have implemented three different machine learning algorithms, i.e., logistic regression, an artificial neural network, and a support vector machine. After each algorithm performs the decision process independently, the decision-making module collects these individual decisions and makes a final decision using a majority vote scheme. With this, we performed some simulations and presented some of its results. The contribution of this study is that, by employing more robust and stable algorithms, each of the algorithms performs the recognition task more accurately. Moreover, by integrating these results and employing the majority vote scheme, we can make a definite decision, which makes the self-diagnostic monitoring system more reliable

  5. Preliminary design implications of SSC fixed-target operation

    International Nuclear Information System (INIS)

    Zisman, M.S.

    1984-06-01

    This paper covers some of the accelerator physics issues relevant to a possible fixed-target operating mode for the Superconducting Super Collider (SSC). In the brief time available, no attempt has been made to design this capability into the SSC. Rather, I have tried to evaluate what the performance of such a machine might be, and to indicate the hardware implications and extraction considerations that would be part of an actual design study. Where appropriate, parameters and properties of the present LBL design for the SSC have been used; these should be taken as being representative of the general class of small-aperture, high-field colliders being considered by the accelerator physics community. Thus, the numerical examples given here must ultimately be reexamined in light of the actual parameters of the particular accelerator being considered

  6. THE SIMULATION DIAGNOSTIC METHODS AND REGENERATION WAYS OF REINFORCED - CONCRETE CONSTRUCTIONS OF BRIDGES IN PROVIDING THEIR OPERATING RELIABILITY AND LONGEVITY

    Directory of Open Access Journals (Sweden)

    B. V. Savchinskiy

    2010-03-01

    Full Text Available On the basis of analysis of existing diagnostic methods and regeneration ways of reinforced-concrete constructions of bridges the recommendations on introduction of new modern technologies of renewal of reinforced-concrete constructions of bridges in providing their operating reliability and longevity are offered.

  7. Receiver operating characteristic (ROC) curves: review of methods with applications in diagnostic medicine

    Science.gov (United States)

    Obuchowski, Nancy A.; Bullen, Jennifer A.

    2018-04-01

    Receiver operating characteristic (ROC) analysis is a tool used to describe the discrimination accuracy of a diagnostic test or prediction model. While sensitivity and specificity are the basic metrics of accuracy, they have many limitations when characterizing test accuracy, particularly when comparing the accuracies of competing tests. In this article we review the basic study design features of ROC studies, illustrate sample size calculations, present statistical methods for measuring and comparing accuracy, and highlight commonly used ROC software. We include descriptions of multi-reader ROC study design and analysis, address frequently seen problems of verification and location bias, discuss clustered data, and provide strategies for testing endpoints in ROC studies. The methods are illustrated with a study of transmission ultrasound for diagnosing breast lesions.

  8. Plant diagnostics in power stations

    International Nuclear Information System (INIS)

    Sturm, A.; Doering, D.

    1985-01-01

    The method of noise diagnostics is dealt with as a part of plant diagnostics in nuclear power stations. The following special applications are presented: (1) The modular noise diagnostics system is used for monitoring primary coolant circuits and detecting abnormal processes due to mechanical vibrations, loose parts or leaks. (2) The diagnostics of machines and plants with antifriction bearings is based on bearing vibration measurements. (3) The measurement of the friction moment by means of acoustic emission analysis is used for evaluating the operational state of slide bearings

  9. Complex of electrostatic accelerators for simulation and diagnostics of radiation damage

    International Nuclear Information System (INIS)

    Antuf'ev, Yu.P.; Belyaev, V.Kh.; Vergunov, A.D.

    1983-01-01

    The installation for simulation and diagnostics of radiation damage of materials is described. The installation consists of two electrostatic accelerators of vertical type for 5 MV and horizontal type for 800 kV. The accelerating complex ensures accelerated ion beam production in the independent operation regime as well as in the two beams target simultaneous irradiation regime, energy range of accelerated single-charged ions is 80 keV ... 5 MeV, homogeneity is better than +-0.05%. Oilless vacuum pumping out system is realized at the accelerating complex

  10. [Adrenal tumors. Principles of diagnostics and operative treatment].

    Science.gov (United States)

    Gonsior, A; Pfeiffer, H; Führer, D; Liatsikos, E; Schwalenberg, T; Stolzenburg, J-U

    2010-05-01

    Adrenal masses are very heterogeneous and comprise benign or malignant tumors, unilateral or bilateral masses and variable endocrine activity. Because of these attributes adrenal gland masses are a clinical challenge. This article gives a summary of diagnostic steps and indications for adrenal surgery including perioperative management.

  11. An Advanced Diagnostic Display for Core Protection Calculator System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji-Hyeon; Jeong, See-Chae; Sohn, Se-Do [Korea Power Engineering Company, Daejeon (Korea, Republic of)

    2008-10-15

    The main purpose of a Nuclear Power Plant Instrumentation and Control (I and C) Display System is to provide operator's interface for I and C systems. The CPCS display(Shin-Kori 1 and 2) provides operators with 1) plant monitoring values of field input and algorithm variables that reflect the reactor core conditions, 2) operation values that operators can change and 3) CPCS status. It will be an optimal case if operators can understand the plant (including CPCS itself) condition intuitively with the displayed values but it is not easy in CPCS. For example, if the CPCS Channel Trouble light is lit, operators need some amount of time to investigate what caused the trouble light because there are more than hundred causes that can generate the channel trouble. If a Display supports diagnostic information that shows what cause the displayed alarms, it will greatly help operators in easy understanding the CPCS status. To provide these diagnostic information, this paper suggests an active self-explanatory display mechanism. This self-explanatory diagnostic display mechanism utilizes an ontology in XML that describes parent child, sibling relationships of display variables, through which in-depth, in-breadth diagnostic tracking is possible. This paper consists of two parts. First, the key features of CPCS Flat Panel Display System (FPDS) are described. Second, the features of active self explanatory diagnostic display are discussed.

  12. An Advanced Diagnostic Display for Core Protection Calculator System

    International Nuclear Information System (INIS)

    Kim, Ji-Hyeon; Jeong, See-Chae; Sohn, Se-Do

    2008-01-01

    The main purpose of a Nuclear Power Plant Instrumentation and Control (I and C) Display System is to provide operator's interface for I and C systems. The CPCS display(Shin-Kori 1 and 2) provides operators with 1) plant monitoring values of field input and algorithm variables that reflect the reactor core conditions, 2) operation values that operators can change and 3) CPCS status. It will be an optimal case if operators can understand the plant (including CPCS itself) condition intuitively with the displayed values but it is not easy in CPCS. For example, if the CPCS Channel Trouble light is lit, operators need some amount of time to investigate what caused the trouble light because there are more than hundred causes that can generate the channel trouble. If a Display supports diagnostic information that shows what cause the displayed alarms, it will greatly help operators in easy understanding the CPCS status. To provide these diagnostic information, this paper suggests an active self-explanatory display mechanism. This self-explanatory diagnostic display mechanism utilizes an ontology in XML that describes parent child, sibling relationships of display variables, through which in-depth, in-breadth diagnostic tracking is possible. This paper consists of two parts. First, the key features of CPCS Flat Panel Display System (FPDS) are described. Second, the features of active self explanatory diagnostic display are discussed

  13. IFMIF-LIPAc Beam Diagnostics. Profiling and Loss Monitoring Systems

    International Nuclear Information System (INIS)

    Egberts, J.

    2012-01-01

    The IFMIF accelerator will accelerate two 125 mA continuous wave (cw) deuteron beams up to 40 MeV and blasts them onto a liquid lithium target to release neutrons. The very high beam power of 10 MW pose unprecedented challenges for the accelerator development. Therefore, it was decided to build a prototype accelerator, the Linear IFMIF Prototype Accelerator (LIPAc), which has the very same beam characteristic, but is limited to 9 MeV only. In the frame of this thesis, diagnostics devices for IFMIF and LIPAc have been developed. The diagnostics devices consist of beam loss monitors and interceptive as well as non-interceptive profile monitors. For the beam loss monitoring system, ionization chambers and diamond detectors have been tested and calibrated for neutron and γ radiation in the energy range expected at LIPAc. During these tests, for the first time, diamond detectors were successfully operated at cryogenic temperatures. For the interceptive profilers, thermal simulations were performed to ensure safe operation. For the non-interceptive profiler, Ionization Profile Monitors (IPMs) were developed. A prototype has been built and tested, and based on the findings, the final IPMs were designed and built. To overcome the space charge of accelerator beam, a software algorithm was written to reconstruct the actual beam profile. (author) [fr

  14. Microfluidic Purification and Concentration of Malignant Pleural Effusions for Improved Molecular and Cytomorphological Diagnostics

    Science.gov (United States)

    Go, Derek E.; Talati, Ish; Ying, Yong; Rao, Jianyu; Kulkarni, Rajan P.; Di Carlo, Dino

    2013-01-01

    Evaluation of pleural fluids for metastatic cells is a key component of diagnostic cytopathology. However, a large background of smaller leukocytes and/or erythrocytes can make accurate diagnosis difficult and reduce specificity in identification of mutations of interest for targeted anti-cancer therapies. Here, we describe an automated microfluidic system (Centrifuge Chip) which employs microscale vortices for the size-based isolation and concentration of cancer cells and mesothelial cells from a background of blood cells. We are able to process non-diluted pleural fluids at 6 mL/min and enrich target cells significantly over the background; we achieved improved purity in all patient samples analyzed. The resulting isolated and viable cells are readily available for immunostaining, cytological analysis, and detection of gene mutations. To demonstrate the utility towards aiding companion diagnostics, we also show improved detection accuracy of KRAS gene mutations in lung cancer cells processed using the Centrifuge Chip, leading to an increase in the area under the curve (AUC) of the receiver operating characteristic from 0.90 to 0.99. The Centrifuge Chip allows for rapid concentration and processing of large volumes of bodily fluid samples for improved cytological diagnosis and purification of cells of interest for genetic testing, which will be helpful for enhancing diagnostic accuracy. PMID:24205153

  15. Beam Instrumentation and Diagnostics

    CERN Document Server

    Strehl, Peter

    2006-01-01

    This treatise covers all aspects of the design and the daily operations of a beam diagnostic system for a large particle accelerator. A very interdisciplinary field, it involves contributions from physicists, electrical and mechanical engineers and computer experts alike so as to satisfy the ever-increasing demands for beam parameter variability for a vast range of operation modi and particles. The author draws upon 40 years of research and work, most of them spent as the head of the beam diagnostics group at GSI. He has illustrated the more theoretical aspects with many real-life examples that will provide beam instrumentation designers with ideas and tools for their work.

  16. Low-temperature H2-4He and H2-3He targets for operation on an electron beam

    International Nuclear Information System (INIS)

    Gol'dshtejn, V.A.; Lubyanyj, V.V.

    1981-01-01

    Structures and basic characteristics of H 2 - 4 He and H 2 - 3 He low temperature targets are given. Technique of 3 He target filling is described. Initial target cooling up to liquid 4 He temperature and its filling up take near approximately 1 h, at that 4 He flow rate equals 15 l. Repeated filling up of 4 He takes 20 min, and target filling up with 3 He - 10-15 min. Good thermal insulation of a cryostat and targets permits the 4 He target to be operated with an electron beam of a mean current of up to 0.5 μA without filling up 4 He for 70 h. At that flow rate of liquid 4 He amounts to 0.2 l/h, and liquid hydrogen - 0.04 l/h. It is concluded that H 2 - 4 He and H 2 - 3 He targets are reliable and simple in operation and permit to work with accelerated particle beams of intensity corresponding to power release >= 0.5 W without corrections for density change [ru

  17. Diagnostics developments and applications for laser fusion experiments

    International Nuclear Information System (INIS)

    Coleman, L.W.

    1977-01-01

    Some diagnostics techniques applied to current laser fusion target experiments are reviewed. Specifically, holographic interferometry of target plasmas, coded aperture imaging of thermonuclear alpha-particles and neutron energy spectrum measurements are discussed

  18. Diagnostic efficacy of radiological examinations in clefts of the hard palate

    International Nuclear Information System (INIS)

    Cieslinska-Wilk, G.

    1992-01-01

    The aim of the work has been: 1) evaluating the efficiency of individual radiological methods in visualizing the bone structure of the hard palate; 2) elaboration of a method for skull examination, by means of which the hard palate region in patients would be best visible; 3) presentation of radiological symptomatology of hard palate clefts; 4) establishing algorithms of diagnostic procedure and determining the type of radiological examination most helpful in planning the treatment of this anomaly. Selected problems from normal anatomy of the hard palate are presented, and the technique of radiological examination in the form of occlusal radiograms, pantomography and computerized tomography (CT) are discussed. Clinical material encompassed the total of 312 patients. A total of 470 radiograms were performed, 150 occlusal ones of hard palate, 200 pantomograms (jointly with the control group) as well as 120 scannings during CT examination. It has been stated the greatest efficiency and effectiveness in planning the treatment are ascribed to computerized tomography, the second place goes to pantomography, on the third position are occlusal radiograms targeted at the region of the cleft. Algorithms have been provided for roentgen-diagnostic procedure in cases of the hard palate clefts, with an emphasis that the very first examination of a child should include the occlusal radiograms targeted at the cleft region and pantomogram; in the course of conservative treatment only pantomogram is proposed to be made, and in case of planned operative procedure - CT examination. For evaluating the calcification of the cleft, the best and with the least irradiation are the intraoral occlusal radiograms, targeted at the region of the cleft, performed 12 months after the operation. (author). 100 refs, 21 figs, 12 tabs

  19. Towards diagnostics for a fusion reactor

    International Nuclear Information System (INIS)

    Costley, A. E.

    2009-01-01

    The requirements for measurements on modern tokamak fusion plasmas are outlined, and the techniques and systems used to make the measurements, usually referred to as 'diagnostics', are introduced. The basics of three particular diagnostics - magnetics, neutron systems and a laser based optical system - are outlined as examples of modern diagnostic systems, and the implementation of these diagnostics on a current tokamak (JET) are described. The next major step in magnetic confinement fusion is the construction and operation of the International Thermonuclear Experimental Reactor (ITER), which is a joint project of China, Europe, Japan, India, Korea, the Russian Federation, and the United States. Construction has begun in Cadarache, France. It is expected that ITER will operate at the 500 MW level. Because of the harsh environment in the vacuum vessel where many diagnostic components are located, the development of diagnostics for ITER is a major challenge - arguably the most difficult challenge ever undertaken in the field of diagnostics. The main elements in the diagnostic step are outlined using the three chosen techniques as examples. Finally, the step beyond ITER to a demonstration reactor, DEMO, that is expected to produce several GWs of fusion power is considered and the impact on diagnostics outlined. It is shown that the applicability and development steps needed for the individual diagnostics techniques will differ. The challenges for DEMO diagnostics are substantial and a dedicated effort should be made to find and develop new techniques, and especially techniques appropriate to the DEMO environment. It is argued that the limitations and difficulties in diagnostics should be a consideration in the optimization and designs of DEMO. (author)

  20. It's diagnostics, stupid.

    Science.gov (United States)

    Bernards, René

    2010-04-02

    To stem the spiraling cost of cancer treatment, a concerted effort is urgently needed to develop molecular diagnostics to better identify the patients that respond to expensive targeted therapies. Opportunities and obstacles in the development of such drug response biomarkers are discussed here. Copyright 2010 Elsevier Inc. All rights reserved.

  1. Diagnostic system for primary circuits of pressurized-water reactors

    International Nuclear Information System (INIS)

    Liska, J.; Majer, J.

    1983-01-01

    The diagnostic system monitors the reactor, the main circulating pipe, the main circulating pump, the main shut-off valve, the steam generator and the pressurizer. Diagnostic signals are obtained from the sensors designed for operation measurements and from sensors for special diagnostic purposes. The following operations are carried out: detection of dangerous dynamic stress of components, detection of damage to functional surfaces of components, detection of occurrence and propagation of defects in component materials, detection of loose particles and foreign bodies, detection of coolant leakage, detection of coolant boiling in the core and detection of impermissible non-homogeneities of fields of physical quantities in the core. The diagnostic system comprises: monitoring, classification of properly investigated effects, periodical tracing and long-term tracing. The operational diagnostics system developed by the SKODA Concern consists of a vibration monitoring system, a spectral analysis system and a central evaluation system. (M.D.)

  2. NRC Information Notice No. 93-01: Accuracy of motor-operated valve diagnostic equipment manufactured by Liberty Technologies

    International Nuclear Information System (INIS)

    Grimes, B.K.

    1993-01-01

    Most licensees rely on MOV diagnostic equipment to provide information on the thrust delivered by the motor actuator in opening or closing its valve. The various types of MOV diagnostic equipment estimate valve stem thrust using different parameters, such as displacement of the spring pack or strain in the stem, mounting bolts, or yoke. Liberty Technologies has developed MOV diagnostic equipment, referred to as the Valve Operation Test and Evaluation System (VOTES), that estimates the thrust needed to open or close a valve based on strain of the valve yoke. The VOTES equipment derives thrust from yoke strain that has been calibrated to stem thrust using measured diametral strain of the valve stem and nominal engineering material properties. On October 2, 1992, Liberty Technologies notified the NRC that it had determined that two new factors can affect the thrust values obtained with its equipment. Those factors involve (1) the possible use of improper stem material constants and (2) the failure to account for a torque effect when the VOTES equipment is calibrated by measuring strain in the threaded portion of the valve stem. Liberty Technologies provided information on performing manual calculations to address these factors and stated that its new software, Version 2.3, assists in performing corrections to the thrust data

  3. Diagnostic Magnetic Resonance Imaging of Atherosclerosis in Apolipoprotein E Knockout Mouse Model Using Macrophage-Targeted Gadolinium-Containing Synthetic Lipopeptide Nanoparticles.

    Directory of Open Access Journals (Sweden)

    Zu T Shen

    Full Text Available Cardiovascular disease is the leading cause of death in Western cultures. The vast majority of cardiovascular events, including stroke and myocardial infarction, result from the rupture of vulnerable atherosclerotic plaques, which are characterized by high and active macrophage content. Current imaging modalities including magnetic resonance imaging (MRI aim to characterize anatomic and structural features of plaques rather than their content. Previously, we reported that macrophage-targeted delivery of gadolinium (Gd-based contrast agent (GBCA-HDL using high density lipoproteins (HDL-like particles significantly enhances the detection of plaques in an apolipoprotein (apo E knockout (KO mouse model, with an atherosclerotic wall/muscle normalized enhancement ratio (NER of 120% achieved. These particles are comprised of lipids and synthetic peptide fragments of the major protein of HDL, apo A-I, that contain a naturally occurring modification which targets the particles to macrophages. Targeted delivery minimizes the Gd dose and thus reduces the adverse effects of Gd. The aims of the current study were to test whether varying the GBCA-HDL particle shape and composition can further enhance atherosclerotic plaque MRI and control organ clearance of these agents. We show that the optimized GBCA-HDL particles are efficiently delivered intracellularly to and uptaken by both J774 macrophages in vitro and more importantly, by intraplaque macrophages in vivo, as evidenced by NER up to 160% and higher. This suggests high diagnostic power of our GBCA-HDL particles in the detection of vulnerable atherosclerotic plaques. Further, in contrast to discoidal, spherical GBCA-HDL exhibit hepatic clearance, which could further diminish adverse renal effects of Gd. Finally, activated macrophages are reliable indicators of any inflamed tissues and are implicated in other areas of unmet clinical need such as rheumatoid arthritis, sepsis and cancer, suggesting the

  4. Solid targets and irradiation facilities for production of diagnostic and therapeutic radionuclides at the Debrecen cyclotron

    International Nuclear Information System (INIS)

    Tarkanyi, F.; Ando, L.; Szucs, Z.; Mahunka, I.; Kovacs, Z.

    2000-01-01

    The MGC-20E (NIIEFA, Leningrad, USSR) variable energy compact cyclotron (k=20) was installed in ATOMKI (Debrecen, Hungary) in 1985. Protons, deuterons, 3 He- and α-particles can be accelerated with currents up to 300 μA for internal irradiation and up to 50 μA for external beams. The establishment of the Cyclotron Laboratory was partly supported by the International Atomic Energy Agency. The application of the cyclotron is multipurpose: basic nuclear research, application of activation technique for analytical and wear studies, application of intense fast neutron source for agro-biological, bio-medical application and for radiation damage test of electronic components, and finally radioisotope production for medical diagnostics and for other scientific and applied fields. The cyclotron laboratory has six target rooms, a radiochemistry laboratory and a medical unit equipped with PET

  5. Neutron time-of-flight ion temperature diagnostic for inertial confinement fusion experiments

    International Nuclear Information System (INIS)

    Chrien, R.E.; Simmons, D.F.; Holmberg, D.L.

    1992-01-01

    We are constructing a T i diagnostic for low neutron yield (5 x 10 7 to above 10 9 ) d-d and d-t targets in the Nova facility at Livermore. The diagnostic measures the neutron energy spread with 960 scintillator-photomultiplier detectors located 28 m from the target and operates in the single-hit mode. Each detector can measure a single neutron arrival with time resolution of 1 ns or better. The arrival time distribution is constructed from the results of typically 200--500 detector measurements. The ion temperature is determined from the spread in neutron energy ΔE n ∝ T i 1/2 , which is related to the arrival time spread by Δt/t = 1(1/2 ΔE n /E n ). Each neutron arrival is detected by using a photomultiplier tube to observe the recoil proton from elastic scattering in a fast plastic scintillator. The timing electronics for each channel consist of a novel constant fraction-like discriminator and a multiple hit time-to-digital converter (TDC). The overall system design, together with single channel performance data, is presented

  6. Safety-technical lay-out of the operational environment of a high-power spallation target system of the megawatt class with mercury as target material

    International Nuclear Information System (INIS)

    Butzek, M.

    2005-06-01

    This thesis is concerning the safety relevant layout of the environment of a mercury based 5-Megawatt-spallation target. All safety relevant aspects related to construction, operation and dismantling as well as economical issues were taken into account. Safety concerns are basically driven by the toxic and radioactive inventory as well as the kind and intensity of radiation produced by the spallation process. Due to significant differences in inventory and radiation between a spallation source and a fission reactor, for the design of the spallation source mentioned above the safety philosophy of a fission reactor must not be used unchanged. Rather than this a systematic study of all safety related boundary conditions is necessary. Within this thesis all safety relevant boundary conditions for this specific type of machine are given. Beside the spatial distribution of different areas inside the target station, influence of medias to be used as well as arising radiation and handling requirements are discussed in detail. A general layout of the target station is presented, serving as a basis for all further component and system development. An enclosure concept for the target station was developed, taking into account the safety relevant issues concerning the mercury used as target materials, the water cooling loops containing massive amounts of tritium as well as the materials used for the moderators potentially forming explosive mixtures. Concept and detailed technical layout of the enclosure system was chosen to guarantee safe operation of the source as well as taking care of requirement arising for handling needs. For design of the shielding different suitable materials have been discussed. A design for assembling the shielding is shown taking into account the safety relevant requirements during operation as well as during dismantling. The neutron beam shutters, buried inside the shielding were designed to optimize handling and positioning issued of the inner part

  7. Diagnostics comparing sea surface temperature feedbacks from operational hurricane forecasts to observations

    Directory of Open Access Journals (Sweden)

    Ian D. Lloyd

    2011-11-01

    Full Text Available This paper examines the ability of recent versions of the Geophysical Fluid Dynamics Laboratory Operational Hurricane Forecast Model (GHM to reproduce the observed relationship between hurricane intensity and hurricane-induced Sea Surface Temperature (SST cooling. The analysis was performed by taking a Lagrangian composite of all hurricanes in the North Atlantic from 1998–2009 in observations and 2005–2009 for the GHM. A marked improvement in the intensity-SST relationship for the GHM compared to observations was found between the years 2005 and 2006–2009 due to the introduction of warm-core eddies, a representation of the loop current, and changes to the drag coefficient parameterization for bulk turbulent flux computation. A Conceptual Hurricane Intensity Model illustrates the essential steady-state characteristics of the intensity-SST relationship and is explained by two coupled equations for the atmosphere and ocean. The conceptual model qualitatively matches observations and the 2006–2009 period in the GHM, and presents supporting evidence for the conclusion that weaker upper oceanic thermal stratification in the Gulf of Mexico, caused by the introduction of the loop current and warm core eddies, is crucial to explaining the observed SST-intensity pattern. The diagnostics proposed by the conceptual model offer an independent set of metrics for comparing operational hurricane forecast models to observations.

  8. Theoretical studies of flash x-ray diagnostics for fuel motion experiments

    International Nuclear Information System (INIS)

    Halbleib, J.A. Sr.; Phillips, A.R.

    1975-09-01

    The results of preliminary theoretical studies concerning the possible employment of short-pulse, high-current field emission diodes as sources for the flash x-ray diagnostics of fuel-pin motion are reported. The predicted thick-target photon environments are obtained from state-of-the-art coupled electron/photon transport models. Through qualitative figures of merit these environments are used to study the importance of source current and voltage. For a selected experimental configuration a comparison is made between the absolute flash x-ray imaging signals predicted for these environments and Monte Carlo/analytic calculations of absolute fission-gamma backgrounds. These preliminary data suggest that field emission sources operating at voltages in the 1-to 5-MeV range and at currents of the order of 100-kA or greater may be adequate diagnostic sources for test-pin configurations as complex as a full LMFBR subassembly

  9. ICF gamma-ray reaction history diagnostics

    International Nuclear Information System (INIS)

    Herrmann, H W; Young, C S; Mack, J M; Kim, Y H; McEvoy, A; Evans, S; Sedillo, T; Batha, S; Schmitt, M; Wilson, D C; Langenbrunner, J R; Malone, R; Kaufman, M I; Cox, B C; Frogget, B; Tunnell, T W; Miller, E K; Ali, Z A; Stoeffl, W; Horsfield, C J

    2010-01-01

    Reaction history measurements, such as nuclear bang time and burn width, are fundamental components of diagnosing ICF implosions and will be employed to help steer the National Ignition Facility (NIF) towards ignition. Fusion gammas provide a direct measure of nuclear interaction rate (unlike x-rays) without being compromised by Doppler spreading (unlike neutrons). Gas Cherenkov Detectors that convert fusion gamma rays to UV/visible Cherenkov photons for collection by fast optical recording systems have established their usefulness in illuminating ICF physics in several experimental campaigns at OMEGA. In particular, bang time precision better than 25 ps has been demonstrated, well below the 50 ps accuracy requirement defined by the NIF. NIF Gamma Reaction History (GRH) diagnostics are being developed based on optimization of sensitivity, bandwidth, dynamic range, cost, and NIF-specific logistics, requirements and extreme radiation environment. Implementation will occur in two phases. The first phase consists of four channels mounted to the outside of the target chamber at ∼6 m from target chamber center (GRH-6m) coupled to ultra-fast photo-multiplier tubes (PMT). This system is intended to operate in the 10 13 -10 17 neutron yield range expected during the early THD campaign. It will have high enough bandwidth to provide accurate bang times and burn widths for the expected THD reaction histories (> 80 ps fwhm). Successful operation of the first GRH-6m channel has been demonstrated at OMEGA, allowing a verification of instrument sensitivity, timing and EMI/background suppression. The second phase will consist of several channels located just inside the target bay shield wall at 15 m from target chamber center (GRH-15m) with optical paths leading through the cement shield wall to well-shielded streak cameras and PMTs. This system is intended to operate in the 10 16 -10 20 yield range expected during the DT ignition campaign, providing higher temporal resolution

  10. ICF gamma-ray reaction history diagnostics

    Science.gov (United States)

    Herrmann, H. W.; Young, C. S.; Mack, J. M.; Kim, Y. H.; McEvoy, A.; Evans, S.; Sedillo, T.; Batha, S.; Schmitt, M.; Wilson, D. C.; Langenbrunner, J. R.; Malone, R.; Kaufman, M. I.; Cox, B. C.; Frogget, B.; Miller, E. K.; Ali, Z. A.; Tunnell, T. W.; Stoeffl, W.; Horsfield, C. J.; Rubery, M.

    2010-08-01

    Reaction history measurements, such as nuclear bang time and burn width, are fundamental components of diagnosing ICF implosions and will be employed to help steer the National Ignition Facility (NIF) towards ignition. Fusion gammas provide a direct measure of nuclear interaction rate (unlike x-rays) without being compromised by Doppler spreading (unlike neutrons). Gas Cherenkov Detectors that convert fusion gamma rays to UV/visible Cherenkov photons for collection by fast optical recording systems have established their usefulness in illuminating ICF physics in several experimental campaigns at OMEGA. In particular, bang time precision better than 25 ps has been demonstrated, well below the 50 ps accuracy requirement defined by the NIF. NIF Gamma Reaction History (GRH) diagnostics are being developed based on optimization of sensitivity, bandwidth, dynamic range, cost, and NIF-specific logistics, requirements and extreme radiation environment. Implementation will occur in two phases. The first phase consists of four channels mounted to the outside of the target chamber at ~6 m from target chamber center (GRH-6m) coupled to ultra-fast photo-multiplier tubes (PMT). This system is intended to operate in the 1013-1017 neutron yield range expected during the early THD campaign. It will have high enough bandwidth to provide accurate bang times and burn widths for the expected THD reaction histories (> 80 ps fwhm). Successful operation of the first GRH-6m channel has been demonstrated at OMEGA, allowing a verification of instrument sensitivity, timing and EMI/background suppression. The second phase will consist of several channels located just inside the target bay shield wall at 15 m from target chamber center (GRH-15m) with optical paths leading through the cement shield wall to well-shielded streak cameras and PMTs. This system is intended to operate in the 1016-1020 yield range expected during the DT ignition campaign, providing higher temporal resolution for the

  11. Development and improvement of the operating diagnostics systems of NPO CKTI works for turbine of thermal and nuclear power plants

    Science.gov (United States)

    Kovalev, I. A.; Rakovskii, V. G.; Isakov, N. Yu.; Sandovskii, A. V.

    2016-03-01

    The work results on the development and improvement of the techniques, algorithms, and software-hardware of continuous operating diagnostics systems of rotating units and parts of turbine equipment state are presented. In particular, to ensure the full remote service of monitored turbine equipment using web technologies, the web version of the software of the automated systems of vibration-based diagnostics (ASVD VIDAS) was developed. The experience in the automated analysis of data obtained by ASVD VIDAS form the basis of the new algorithm of early detection of such dangerous defects as rotor deflection, crack in the rotor, and strong misalignment of supports. The program-technical complex of monitoring and measuring the deflection of medium pressure rotor (PTC) realizing this algorithm will alert the electric power plant staff during a deflection and indicate its value. This will give the opportunity to take timely measures to prevent the further extension of the defect. Repeatedly, recorded cases of full or partial destruction of shrouded shelves of rotor blades of the last stages of low-pressure cylinders of steam turbines defined the need to develop a version of the automated system of blade diagnostics (ASBD SKALA) for shrouded stages. The processing, analysis, presentation, and backup of data characterizing the mechanical state of blade device are carried out with a newly developed controller of the diagnostics system. As a result of the implementation of the works, the diagnosed parameters determining the operation security of rotating elements of equipment was expanded and the new tasks on monitoring the state of units and parts of turbines were solved. All algorithmic solutions and hardware-software implementations mentioned in the article were tested on the test benches and applied at some power plants.

  12. Effects of TEL Confusers on Operator Target Acquisition Performance with SAR Imagery

    Science.gov (United States)

    1998-12-01

    efforts of everyone involved in the project; and Dr. Nick Patton, for providing assistance with several of the mathematical procedures in the document...processing known as the theory of signal detection (TSD) (Gescheider, 1985; Green & Swets, 1966; Macmillan & Creelman , 1991; Wilson, 1992). A TSD...localizations (Hacker & Ratcliff, 1979; Macmillan & Creelman , 1991). The index of bias in a target localization task provides a measure of the operator’s

  13. Summary receiver operating characteristic curves as a technique for meta-analysis of the diagnostic performance of duplex ultrasonography in peripheral arterial disease

    NARCIS (Netherlands)

    deVries, SO; Hunink, MGM; Polak, JF

    Rationale and Objectives. We summarized and compared the diagnostic performance of duplex and color-guided duplex ultrasonography in the evaluation of peripheral arterial disease. We present our research as an example of the use of summary receiver operating characteristic (ROC) curves in a

  14. Status of TMX upgrade diagnostics construction

    International Nuclear Information System (INIS)

    Hornady, R.S.; Davis, J.C.; Simonen, T.C.

    1981-01-01

    This report describes the status of the initial TMX Upgrade diagnostics and the state of development of additional diagnostics being prepared for later TMX Upgrade experiments. The initial diagnostic instrument set has been described in the TMX Upgrade Proposal. This set is required to get TMX Upgrade operational and to evaluate its initial performance. Additional diagnostic instruments are needed to then carry out the more detailed experiments outlined by the TMX Upgrade program milestones. The relation of these new measurements to the physics program is described in The TMX Upgrade Program Plan

  15. Radiation shielding for TFTR DT diagnostics

    International Nuclear Information System (INIS)

    Ku, L.P.; Johnson, D.W.; Liew, S.L.

    1994-01-01

    The authors illustrate the designs of radiation shielding for the TFTR DT diagnostics using the ACX and TVTS systems as specific examples. The main emphasis here is on the radiation transport analyses carried out in support of the designs. Initial results from the DT operation indicate that the diagnostics have been functioning as anticipated and the shielding designs are satisfactory. The experience accumulated in the shielding design for the TFTR DT diagnostics should be useful and applicable to future devices, such as TPX and ITER, where many similar diagnostic systems are expected to be used

  16. Diagnostic development

    International Nuclear Information System (INIS)

    Barnett, C.F.; Brisson, D.A.; Greco, S.E.

    1978-01-01

    During the past year the far-infrared or submillimeter diagnostic research program resulted in three major developments: (1) an optically pumped 0.385-μm D 2 O-laser oscillator-amplifier system was operated at a power level of 1 MW with a line width of less than 50 MHz; (2) a conical Pyrex submillimeter laser beam dump with a retention efficiency greater than 10 4 was developed for the ion temperature Thompson scattering experiment; and (3) a new diagnostic technique was developed that makes use of the Faraday rotation of a modulated submillimeter laser beam to determine plasma current profile. Measurements of the asymmetric distortion of the H/sub α/ (6563 A) spectral line profile show that the effective toroidal drift velocity, dv/sub two vertical bars i/dT/sub i/, may be used as an indicator of plasma quality and as a complement to other ion temperature diagnostics

  17. Impact of antepartum diagnostic amnioinfusion on targeted ultrasound imaging of pregnancies presenting with severe oligo- and anhydramnios: An analysis of 61 cases.

    Science.gov (United States)

    Vikraman, Seneesh Kumar; Chandra, Vipin; Balakrishnan, Bijoy; Batra, Meenu; Sethumadhavan, Sreeja; Patil, Swapneel Neelkanth; Nair, Sabila; Kannoly, Gopinathan

    2017-05-01

    The primary objective our study was to assess the role of diagnostic antepartum amnioinfusion on the yield from targeted ultrasounds performed in pregnancies with severe oligo- and anhydramnios. This was a retrospective and descriptive study, conducted in the fetal medicine units of two private tertiary care referral centers in south India. The details of all the cases of diagnostic amnioinfusion performed at these two centers from January 2009 to June 2016 were collected and analyzed. Inclusion criteria were pregnancies between 17 and 26 weeks of gestational age with severe oligo- or anhydramnios. Pregnancies with obvious preterm premature rupture of membranes (PPROM) were excluded. The primary outcome measure was the improvement in diagnostic information pertaining to cause of severe oligo- and anhydramnios, and the nature of such anomalies. A total of 61 cases of were identified. The median gestational age at performance of the procedure was 22 weeks [IQR, 19.5-23]. The mean volume of normal saline infused was 314±54ml. A significant increase in the single vertical pocket (SVP) was observed following the procedure (pre-procedure SVP=0.6±0.9cm, post procedure SVP=3.4±1.7; paired t test, pamnioinfusion is a valuable ancillary technique in prenatal diagnosis as it increases the diagnostic yield from pregnancies presenting with severe oligo- and anhydramnios. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. A universal molecular translator for non-nucleic acid targets that enables dynamic DNA assemblies and logic operations.

    Science.gov (United States)

    Tang, Wei; Hu, Shichao; Wang, Huaming; Zhao, Yan; Li, Na; Liu, Feng

    2014-11-28

    A universal molecular translator based on the target-triggered DNA strand displacement was developed, which was able to convert various kinds of non-nucleic acid targets into a unique output DNA. This translation strategy was successfully applied in directing dynamic DNA assemblies and in realizing three-input logic gate operations.

  19. Multifunctional Nanomaterials Utilizing Hybridization Chain Reaction for Molecular Diagnostics and Bioanalytical Applications

    Science.gov (United States)

    Rana, Md. Muhit

    DNA nanotechnology has shown great promise in molecular diagnostic, bioanalytical and biomedical applications. The great challenge of detecting target analytes, biomarkers and small molecules, in molecular diagnostics is low yield sensitivity. To address this challenge, different nanomaterials have been used for a long time and to date there is no such cost-effective bioanalytical technique which can detect these target biomarkers (DNA, RNA, circulating DNA/miRNA) or environmental heavy metal ions (Hg2+ and Ag+) in a cost-effective and efficient manner. Herein, we initially discuss two possible bioanalytical detection methods- a) colorimetric and b) fluorometric assays which are very popular nowadays due to their distinctive spectroscopic properties. Finally, we report the promising colorimetric assay using a novel DNA based amplification strategy know as hybridization chain reaction (HCR) for potential application in the visual detection of low copies of biomarkers (miRNAs as little as 20 femtomole in an RNA pool and cell extracts in seven different combinations and Ebola virus DNA as low as 400 attomoles in liquid biopsy mimics in sixteen different combinations), environmental and biological heavy metal ions (mercury and silver concentrations as low as 10 pM in water, soil and urine samples) and also successfully applied to a molecular logic gate operation to distinguish OR and AND logic gates. No results showed any false-positive or false-negative information. On the other hand, we also discuss the future possibilities of HCR amplification technology, which is very promising for fluorometric bioanalysis. The HCR based nanoprobe technology has numerous remarkable advantages over other methods. It is re-programmable, simple, inexpensive, easy to assemble and operate and can be performed with visual and spectroscopic read-outs upon recognition of the target analytes. This rapid, specific and sensitive approach for biomarkers and heavy metal ion detection generates

  20. Molecular Diagnostics, Targeted Therapy, and the Indication for Allogeneic Stem Cell Transplantation in Acute Lymphoblastic Leukemia

    Directory of Open Access Journals (Sweden)

    Anthony Oyekunle

    2011-01-01

    Full Text Available In recent years, the panel of known molecular mutations in acute lymphoblastic leukemia (ALL has been continuously increased. In Philadelphia-positive ALL, deletions of the IKZF1 gene were identified as prognostically adverse factors. These improved insights in the molecular background and the clinical heterogeneity of distinct cytogenetic subgroups may allow most differentiated therapeutic decisions, for example, with respect to the indication to allogeneic HSCT within genetically defined ALL subtypes. Quantitative real-time PCR allows highly sensitive monitoring of the minimal residual disease (MRD load, either based on reciprocal gene fusions or immune gene rearrangements. Molecular diagnostics provided the basis for targeted therapy concepts, for example, combining the tyrosine kinase inhibitor imatinib with chemotherapy in patients with Philadelphia-positive ALL. Screening for BCR-ABL1 mutations in Philadelphia-positive ALL allows to identify patients who may benefit from second-generation tyrosine kinase inhibitors or from novel compounds targeting the T315I mutation. Considering the central role of the molecular techniques for the management of patients with ALL, efforts should be made to facilitate and harmonize immunophenotyping, cytogenetics, and molecular mutation screening. Furthermore, the potential of high-throughput sequencing should be evaluated for diagnosis and follow-up of patients with B-lineage ALL.

  1. Gold-manganese nanoparticles for targeted diagnostic and imaging

    Energy Technology Data Exchange (ETDEWEB)

    Murph, Simona Hunyadi [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-11-10

    Imagine the possibility of non-invasive, non-radiation based Magnetic resonance imaging (MRI) in combating cardiac disease. Researchers at the Savannah River National Laboratory (SRNL) are developing a process that would use nanotechnology in a novel, targeted approach that would allow MRIs to be more descriptive and brighter, and to target specific organs. Researchers at SRNL have discovered a way to use multifunctional metallic gold-manganese nanoparticles to create a unique, targeted positive contrast agent. SRNL Senior Scientist Dr. Simona Hunyadi Murph says she first thought of using the nanoparticles for cardiac disease applications after learning that people who survive an infarct exhibit up to 15 times higher rate of developing chronic heart failure, arrhythmias and/or sudden death compared to the general population. Without question, nanotechnology will revolutionize the future of technology. The development of functional nanomaterials with multi-detection modalities opens up new avenues for creating multi-purpose technologies for biomedical applications.

  2. Transformer engineering design, technology, and diagnostics

    CERN Document Server

    Kulkarni, SV

    2012-01-01

    Transformer Engineering: Design, Technology, and Diagnostics, Second Edition helps you design better transformers, apply advanced numerical field computations more effectively, and tackle operational and maintenance issues. Building on the bestselling Transformer Engineering: Design and Practice, this greatly expanded second edition also emphasizes diagnostic aspects and transformer-system interactions. What's New in This Edition Three new chapters on electromagnetic fields in transformers, transformer-system interactions and modeling, and monitoring and diagnostics An extensively revised chap

  3. Mammary carcinoma diagnostics and therapy

    International Nuclear Information System (INIS)

    Fischer, Uwe; Baum, Friedemann

    2014-01-01

    The book on mammary carcinoma diagnostics and therapy covers the following issues: development, anatomy and physiology of the mammary glands, pathology of benign and malign mammary gland changes, non-imaging diagnostics; mammography; ultrasonic mammography; magnetic resonance tomography of the mammary glands; imaging diagnostics findings; mammary interventions; examination concepts; operative therapy of the mammary carcinoma; chemotherapy of the mammary carcinoma; radio-oncological therapy of the mammary carcinoma; logistics in a medical center for mammary gland diseases; logistics in an interdisciplinary center for mammary diseases; dialogue conduction and psycho-social attendance.

  4. Plasma Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Zaveryaev, V [Kurchatov Institute, Moscow (Russian Federation); others, and

    2012-09-15

    The success in achieving peaceful fusion power depends on the ability to control a high temperature plasma, which is an object with unique properties, possibly the most complicated object created by humans. Over years of fusion research a new branch of science has been created, namely plasma diagnostics, which involves knowledge of almost all fields of physics, from electromagnetism to nuclear physics, and up-to-date progress in engineering and technology (materials, electronics, mathematical methods of data treatment). Historically, work on controlled fusion started with pulsed systems and accordingly the methods of plasma parameter measurement were first developed for short lived and dense plasmas. Magnetically confined hot plasmas require the creation of special experimental techniques for diagnostics. The diagnostic set is the most scientifically intensive part of a plasma device. During many years of research operation some scientific tasks have been solved while new ones arose. New tasks often require significant changes in the diagnostic system, which is thus a very flexible part of plasma machines. Diagnostic systems are designed to solve several tasks. As an example here are the diagnostic tasks for the International Thermonuclear Experimental Reactor - ITER: (1) Measurements for machine protection and basic control; (2) Measurements for advanced control; (3) Additional measurements for performance evaluation and physics. Every new plasma machine is a further step along the path to the main goal - controlled fusion - and nobody knows in advance what new phenomena will be met on the way. So in the planning of diagnostic construction we should keep in mind further system upgrading to meet possible new scientific and technical challenges. (author)

  5. A free-jet Hg target operating in a high magnetic field intersecting a high-power proton beam

    Science.gov (United States)

    Van Graves; Spampinato, Philip; Gabriel, Tony; Kirk, Harold; Simos, Nicholas; Tsang, Thomas; McDonald, Kirk; Peter Titus; Fabich, Adrian; Haseroth, Helmut; Lettry, Jacques

    2006-06-01

    A proof-of-principal experiment to investigate the interaction of a proton beam, high magnetic field, and high- Z target is planned to take place at CERN in early 2007. This experiment is part of the Muon Collider Collaboration, with participants from Brookhaven National Laboratory, Princeton University, Massachusetts Institute Of Technology, European Organization for Nuclear Research-CERN, Rutherford Appleton Laboratory, and Oak Ridge National Laboratory. An unconstrained mercury jet target system that interacts with a high power (1 MW) proton beam in a high magnetic field (15 T) is being designed. The Hg jet diameter is 1-cm with a velocity up to 20 m/s. A laser optical diagnostic system will be incorporated into the target design to permit observation of the dispersal of the jet resulting from interaction with a 24 GeV proton beam with up to 20×10 12 ppp. The target system includes instruments for sensing mercury vapor, temperature, flow rate, and sump tank level, and the means to position the jet relative to the magnetic axis of a solenoid and the proton beam. The design considerations for the system include all issues dealing with safely handling approximately 23 l of Hg, transporting the target system and the mercury to CERN, decommissioning the experiment, and returning the mildly activated equipment and Hg to the US.

  6. Broadband Liner Optimization for the Source Diagnostic Test Fan

    Science.gov (United States)

    Nark, Douglas M.; Jones, Michael G.

    2012-01-01

    The broadband component of fan noise has grown in relevance with the utilization of increased bypass ratio and advanced fan designs. Thus, while the attenuation of fan tones remains paramount, the ability to simultaneously reduce broadband fan noise levels has become more appealing. This paper describes a broadband acoustic liner optimization study for the scale model Source Diagnostic Test fan. Specifically, in-duct attenuation predictions with a statistical fan source model are used to obtain optimum impedance spectra over a number of flow conditions for three liner locations in the bypass duct. The predicted optimum impedance information is then used with acoustic liner modeling tools to design liners aimed at producing impedance spectra that most closely match the predicted optimum values. Design selection is based on an acceptance criterion that provides the ability to apply increased weighting to specific frequencies and/or operating conditions. Typical tonal liner designs targeting single frequencies at one operating condition are first produced to provide baseline performance information. These are followed by multiple broadband design approaches culminating in a broadband liner targeting the full range of frequencies and operating conditions. The broadband liner is found to satisfy the optimum impedance objectives much better than the tonal liner designs. In addition, the broadband liner is found to provide better attenuation than the tonal designs over the full range of frequencies and operating conditions considered. Thus, the current study successfully establishes a process for the initial design and evaluation of novel broadband liner concepts for complex engine configurations.

  7. Diagnostics of plasma produced by femtosecond laser pulse impact upon a target with an internal nanostructure

    International Nuclear Information System (INIS)

    Skobelev, I. Yu.; Faenov, A. Ya.; Gasilov, S. V.; Pikuz, T. A.; Pikuz, S. A.; Magunov, A. I.; Boldarev, A. S.; Gasilov, V. A.

    2010-01-01

    X-ray diagnostics of the interaction of femtosecond laser pulses with intensities of 10 16 -10 18 W/cm 2 with CO 2 clusters and frozen nanosize water particles is carried out. The stage of cluster expansion and the formation of a plasma channel, which governs the parameters of the formed X-ray radiation source and accelerated ion flows, is studied. The measurements are based on recording spatially resolved X-ray spectra of H- and He-like oxygen ions. Utilization of Rydberg transitions for spectra diagnostics makes it possible to determine plasma parameters on a time scale of t ∼ 10 ps after the beginning of a femtosecond pulse. The role of the rear edge of the laser pulse in sustaining the plasma temperature at a level of ∼100 eV in the stage of a nonadiabatic cluster expansion is shown. The analysis of the profiles and relative intensities of spectral lines allows one to determine the temperature and density of plasma electrons and distinguish the populations of 'thermal' ions and ions that are accelerated up to energies of a few tens of kiloelectronvolts. It is shown that the use of solid clusters made of frozen nanoscale water droplets as targets leads to a substantial increase in the number of fast He-like ions. In this case, however, the efficiency of acceleration of H-like ions does not increase, because the time of their ionization in plasma exceeds the time of cluster expansion.

  8. Potential Diagnostic, Prognostic and Therapeutic Targets of MicroRNAs in Human Gastric Cancer

    Directory of Open Access Journals (Sweden)

    Ming-Ming Tsai

    2016-06-01

    Full Text Available Human gastric cancer (GC is characterized by a high incidence and mortality rate, largely because it is normally not identified until a relatively advanced stage owing to a lack of early diagnostic biomarkers. Gastroscopy with biopsy is the routine method for screening, and gastrectomy is the major therapeutic strategy for GC. However, in more than 30% of GC surgical patients, cancer has progressed too far for effective medical resection. Thus, useful biomarkers for early screening or detection of GC are essential for improving patients’ survival rate. MicroRNAs (miRNAs play an important role in tumorigenesis. They contribute to gastric carcinogenesis by altering the expression of oncogenes and tumor suppressors. Because of their stability in tissues, serum/plasma and other body fluids, miRNAs have been suggested as novel tumor biomarkers with suitable clinical potential. Recently, aberrantly expressed miRNAs have been identified and tested for clinical application in the management of GC. Aberrant miRNA expression profiles determined with miRNA microarrays, quantitative reverse transcription-polymerase chain reaction and next-generation sequencing approaches could be used to establish sample specificity and to identify tumor type. Here, we provide an up-to-date summary of tissue-based GC-associated miRNAs, describing their involvement and that of their downstream targets in tumorigenic and biological processes. We examine correlations among significant clinical parameters and prognostic indicators, and discuss recurrence monitoring and therapeutic options in GC. We also review plasma/serum-based, GC-associated, circulating miRNAs and their clinical applications, focusing especially on early diagnosis. By providing insights into the mechanisms of miRNA-related tumor progression, this review will hopefully aid in the identification of novel potential therapeutic targets.

  9. Multigigahertz beam diagnostics for laser fusion

    International Nuclear Information System (INIS)

    Smith, R.C.; Hodson, E.K.; Carlson, R.L.

    1981-01-01

    A system to make ultra wideband measurements of fast laser pulses and their induced target interactions at a distance of approximately 38 m from the target location is discussed. The system has demonstrated an overall bandwidth of 3 GHz with projected unfolding to 4 GHz. This system allows high resolution temporal history diagnostics in a remote location providing high EMI and radiation immunity

  10. IMPLEMENTATION OF TURNOUTS TECHNICAL DIAGNOSTICS SYSTEMS

    Directory of Open Access Journals (Sweden)

    S. YU. Buryak

    2015-06-01

    Full Text Available Purpose. In the paper it is necessary to: 1 find out the causes of turnouts faults to determine diagnostic features failures; 2 consider the requirements structure, purpose components of turnouts, work and technology of their maintenance to determine the construction of the economic activities related to system to the turnout’s maintenance; 3 substantiate the possibility, necessity and prospects of automated diagnostics turnout’s implementation; 4 elaborate a prototype of an automated hardware and software system for the turnouts control parameters and perform diagnostics on them. Methodology. In the paper possible turnouts faults were presented and manifestations and influence on its work were shown. According to the current technology works the process analyze of turnouts’ maintenance was conducted, were defined the basic performed operations during the examination of appearance, parameters and check the repair or replacement of parts and assemblies. Based on the analysis of reasons of turnouts malfunctioning and their fixes were systematized types of damages and ways to deal with them, an information scheme of troubleshooting were created, opportunities and limits of automating the process of diagnostics were identified and compared with the existing method of turnouts maintenance. A diagnostics system block diagram was created, an algorithm of its work was developed and established main basic principles of operation. Software and hardware to determine the turnout’s state considering diagnostic performance of points in use were applied. Findings. During the experiment was created a method of automated turnout’s diagnostics with AC electric drives, managed centrally. The results of automated hardware and software system make it possible to control turnout’s parameters and perform diagnostics on them. Originality. Authors created the method of turnout’s state determination by current curve and its spectral composition in the

  11. Residual heat removal system diagnostic advisor

    International Nuclear Information System (INIS)

    Tripp, L.

    1991-01-01

    This paper reports on the Residual Heat Removal System (RHRS) Diagnostic Advisor which is an expert system designed to alert the operators to abnormal conditions that exits in the RHRS and offer advice about the cause of the abnormal conditions. The Advisor uses a combination of rule-based and model-based diagnostic techniques to perform its functions. This diagnostic approach leads to a deeper understanding of the RHRS by the Advisor and consequently makes it more robust to unexpected conditions. The main window of the interactive graphic display is a schematic diagram of the RHRS piping system. When a conclusion about a failed component can be reached, the operator can bring up windows that describe the failure mode of the component and a brief explanation about how the Advisor arrived at its conclusion

  12. Diagnostic technology of PWR plant equipment failures

    International Nuclear Information System (INIS)

    Nakamura, Tetsuo; Tanaka, Mamoru; Okamachi, Masao; Taguchi, Shozo; Nagashima, Kazuhiro; Ishikawa, Satoshi

    1985-01-01

    To confirm the soundness of the important facilities in a nuclear power plant contributes to the reliability of the plant operations and improvement of its operation rate. For this purpose, the following diagnostic techniques have been developed. (1). Vibration and loose parts monitoring: Detection of abnormal structural vibrations in the reactor, estimation of its mode, detection of loose parts in the primary system, and estimation of the position and energy of their collisions against the reactor vessel or the like. (2). Valve leak monitoring: Detection of leaks from primary valves in the primary cooling boundary, such as the pressurizer relief valve and safety valve, and estimation of the form of the leaks. (3). Detector noise response diagnosis: Diagnosis of degradation of principal process detectors during plant operation. Furthermore, a diagnostic system incorporating the above diagnostic technology applicable to actual plants has been experimentally manufactured and successfully verified. (author)

  13. The National Ignition Facility (NIF) Diagnostic Set at the Completion of the National Ignition Campaign (NIC) September 2013

    Energy Technology Data Exchange (ETDEWEB)

    Kilkenny, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Bell, P. E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Bradley, D. K. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Bleuel, D. L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Caggiano, J. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Dewald, E. L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Hsing, W. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Kalantar, H. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Kauffman, R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Moody, J. D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Schneider, M. B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Shaughnessy, D. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Shelton, R. T. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Yeamans, C. B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Batha, S. H. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Grim, G. P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Herrmann, H. W. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Merrill, F. E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Leeper, R. J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Sangster, T. C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Edgell, D. H. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Glebov, V. Y. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Regan, S. P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Frenje, J. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Gatu-Johnson, M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Petrasso, R. D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Rindernecht, H. G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Zylstra, A. B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Cooper, G. W. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Ruiz, C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-01-05

    At the completion of the National Ignition Campaign NIF had about 36 different types of diagnostics. These were based on several decades of development on Nova and OMEGA and involved the whole US ICF community. A plan for a limited of NIF Diagnostics was documented by the Joint Central Diagnostic Team in the NIF Conceptual Design Report in 1994. These diagnostics and many more were installed diagnostics by two decades later. We give a short description of each of the 36 different types of NIC diagnostics grouped by the function of the diagnostics, namely target drive, target response and target assembly, stagnation and burn. A comparison of NIF diagnostics with the Nova diagnostics shows that the NIF diagnostic capability is broadly equivalent to that of Nova’s in 1999. NIF diagnostics have a much greater degree of automation and rigor than Nova’s and the NIF diagnostic suite incorporates some scientific innovation compared to Nova and OMEGA namely one much higher speed x-ray imager. Directions for future NIF diagnostics are discussed.

  14. A diagnostic signal selection scheme for planetary gearbox vibration monitoring under non-stationary operational conditions

    International Nuclear Information System (INIS)

    Feng, Ke; Wang, KeSheng; Zhang, Mian; Ni, Qing; Zuo, Ming J

    2017-01-01

    The planetary gearbox, due to its unique mechanical structures, is an important rotating machine for transmission systems. Its engineering applications are often in non-stationary operational conditions, such as helicopters, wind energy systems, etc. The unique physical structures and working conditions make the vibrations measured from planetary gearboxes exhibit a complex time-varying modulation and therefore yield complicated spectral structures. As a result, traditional signal processing methods, such as Fourier analysis, and the selection of characteristic fault frequencies for diagnosis face serious challenges. To overcome this drawback, this paper proposes a signal selection scheme for fault-emphasized diagnostics based upon two order tracking techniques. The basic procedures for the proposed scheme are as follows. (1) Computed order tracking is applied to reveal the order contents and identify the order(s) of interest. (2) Vold–Kalman filter order tracking is used to extract the order(s) of interest—these filtered order(s) constitute the so-called selected vibrations. (3) Time domain statistic indicators are applied to the selected vibrations for faulty information-emphasized diagnostics. The proposed scheme is explained and demonstrated in a signal simulation model and experimental studies and the method proves to be effective for planetary gearbox fault diagnosis. (paper)

  15. Gas targets for the production of 15O, 11C and 18F for PET studies

    International Nuclear Information System (INIS)

    Hichwa, R.D.; Hugel, E.A.; Moskwa, J.J.; Raylman, R.R.

    1987-01-01

    Production of 15 O, 11 C and 18 F is achieved with particle irradiation of gaseous targets. Design features for generalized targets include characterization of window materials and cooling, target size and shape, beam size and profile, and chamber cooling and operating pressure. A cylindrical design is employed that utilizes a C-ring for sealing the target window to the target body. Ultrapure materials are required for fabrication of 11 C and 18 F targets. Use of welded joints are to be limited on all targets and eliminated on 18 F systems. Tomographic techniques will be used to determine the cross-sectional temperature profile of target gases during bombardment. Mass species are measured with a sector focused mass spectrometer while the target undergoes particle irradiation for production of clinical agents. This diagnostic information is useful for tailoring the bombardment conditions to achieve optimal precursor production and the highest specific activity that may be obtained from the target. (orig.)

  16. High-Intensity Laser Diagnostics for OMEGA EP

    International Nuclear Information System (INIS)

    Bromage, J.; Zuegel, J.D.; Bahk, S.-W.; Vickery, D.S.; Waxer, L.J.; Irwin, D.; Bagnoud, V.; Boni, R.; Moore, M.D.; Junquist, R.; Stoeckl, C.

    2006-01-01

    OMEGA EP is a new high-energy petawatt laser system under construction at the University of Rochester's Laboratory for Laser Energetics. This paper describes our designs for two diagnostics critical to OMEGA EP's mission. The focal-spot diagnostic (FSD) is responsible for characterizing the focal spot of OMEGA EP's off-axis parabolic mirror at full energy. The ultrafast temporal diagnostic (UTD) is responsible for characterizing pulse shapes of full-energy target shots ranging in width from <1 to 100 ps as well as setting the desired pulse width before the shot. These diagnostics will enable, for the first time, complete spatial and temporal characterization of the focus of a high-energy petawatt laser at full energy

  17. Reversed field pinch diagnostics

    International Nuclear Information System (INIS)

    Weber, P.G.

    1986-01-01

    The Reversed Field Pinch (RFP) is a toroidal, axisymmetric magnetic confinement configuration characterized by a magnetic field configuration in which the toroidal magnetic field is of similar strength to the poloidal field, and is reversed at the edge compared to the center. The RFP routinely operates at high beta, and is a strong candidate for a compact fusion device. Relevant attributes of the configuration will be presented, together with an overview of present and planned experiments and their diagnostics. RFP diagnostics are in many ways similar to those of other magnetic confinement devices (such as tokamaks); these lectures will point out pertinent differences, and will present some diagnostics which provide special insights into unique attributes of the RFP

  18. Nuclear power plant diagnostics study at the Midland training simulator

    International Nuclear Information System (INIS)

    Reifman, J.; Rank, P.; Lee, J.C.

    1991-01-01

    Training simulators provide a real world environment for testing advanced diagnostic and control systems as an aid to nuclear power plant operators. The simulators not only duplicate the hardware din the actual control room, allowing for analysis of man-machine interface, but also represent the dynamic behavior of the reference plant in real-time, in a realistic manner. Training simulators provide the means to representing the reference plant operations in a wide range of operation conditions including off-normal and emergency conditions. Transient events with very low probability of occurrence can then be represented and used to test the capabilities of advanced diagnostic and control systems. For these reasons, full-scope operator training simulators have been used as a test bed for a number of advanced diagnostic concepts. The University of Michigan and Consumers Power Company have been collaborating in a program devoted to the development and study of advanced concepts for automatic diagnostics and control of nuclear power plants. The program has been focused on the use of the full-scope operator training Midland Nuclear Power Plant Unit 2 (MNP-2) Simulator for development, testing, and verification of advanced diagnostics concepts. In their current efforts, the authors have developed two artificial intelligent (AI) diagnostic concepts that have been applied to the MNP-2 Simulator: the systematic generation and updating of a rule-based knowledge system for nuclear power plant diagnostics and a nonlinear parameter estimation algorithm called the simulation filter. The simulation filter algorithm is used with the MNP-2 Simulator to improve the simulation of the Three Mile Island Unit 2 (TMI-2) accident. 11 refs., 4 figs

  19. Edge Thomson scattering diagnostic on COMPASS tokamak: Installation, calibration,operation, improvements

    Czech Academy of Sciences Publication Activity Database

    Böhm, Petr; Aftanas, Milan; Bílková, Petra; Štefániková, Estera; Mikulín, Ondřej; Melich, Radek; Janky, Filip; Havlíček, Josef; Šesták, David; Weinzettl, Vladimír; Stöckel, Jan; Hron, Martin; Pánek, Radomír; Scannell, R.; Frassinetti, L.; Fassina, A.; Naylor, G.; Walsh, M.J.

    2014-01-01

    Roč. 85, č. 11 (2014), 11E431-11E431 ISSN 0034-6748. [Topical Conference on High-Temperature Plasma Diagnostics/20./. Atlanta, Georgia, 01.06.2014-05.06.2014] R&D Projects: GA MŠk(CZ) LM2011021; GA ČR(CZ) GA14-35260S Institutional support: RVO:61389021 Keywords : plasma * tokamak * pedestal * Thomson scattering * diagnostic Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.614, year: 2014 http://scitation.aip.org/content/aip/journal/rsi/85/11/10.1063/1.4893995

  20. SNS Diagnostics

    International Nuclear Information System (INIS)

    Shea, T.J.; Cameron, P.; Doolittle, L.; Power, J.

    2000-01-01

    The Spallation Neutron Source (SNS) Project is a collaborative effort to build the next generation neutron science facility at Oak Ridge, TN. The facility will deliver a 2 MW proton beam to a liquid mercury target. Neutrons from this target will be moderated and sent to several state-of-the-art instruments. Six national laboratories are involved in SNS construction. Berkeley (LBNL) will build the front end that produces a 2.5 MeV, 52 mA H-beam. Los Alamos (LANL) is responsible for the 1 GeV linac with a superconducting section provided by Thomas Jefferson (JLab). Brookhaven (BNL) is building the transfer lines and accumulator ring. Oak Ridge (ORNL) and Argonne (ANL) have responsibility for the target and instruments. All activities are coordinated by the SNS project office at Oak Ridge. The high beam power, a desired availability of 95%, and an aggressive commissioning schedule lead to some interesting challenges in beam diagnostics

  1. Laser and plasma diagnostics for the OMEGA Upgrade Laser System (invited) (abstract)

    International Nuclear Information System (INIS)

    Letzring, S.A.

    1995-01-01

    The upgraded OMEGA laser system will be capable of delivering up to 30 kJ of 351-nm laser light with various temporal pulse shapes onto a variety of targets for both ICF and basic plasma physics experiments. ICF experiments will cover a wide parameter space up to near-ignition conditions, and basic interaction and plasma physics experiments will cover previously unattainable parameter spaces. The laser system is the tool with which the experiments are performed; the diagnostics, both of the laser system and the interaction between the laser and the target, form the heart of the experiment. A new suite of diagnostics is now being designed and constructed. Most of these are based on diagnostics previously fielded on the OMEGA laser system very successfully over the last ten years, but there are some new diagnostics, both for the laser and the interaction experiments, which have had to be invented. Laser system diagnostics include high-energy, full-beam calorimetry for all of the 60 beams of the upgrade; a novel, multispectral energy-measuring system for assessing the tuning of the frequency-multiplying crystals; a beam-balance diagnostic that forms the heart of the energy-balance system; and a peak power diagnostic that forms the heart of the power-balance system. Target diagnostics will include the usual time-integrated x-ray imaging systems, both pinhole cameras and x-ray microscopes; x-ray spectrometers, both imaging and spatially integrating; plamsa calorimeters, including x-ray calorimetry; and time-resolved x-ray diagnostics, both nonimaging and imaging in one and two dimensions. Neutron diagnostics will include several measurements of total yield, secondary, and possibly tertiary yield and neutron spectroscopy with several time-of-flight spectrometers. Other measurements will include ''knock-on'' particle measurements and neutron activation of shell materials as a diagnostic of compressed fuel and shell density

  2. A Report on Molecular Diagnostic Testing for Inherited Retinal Dystrophies by Targeted Genetic Analyses.

    Science.gov (United States)

    Ramkumar, Hema L; Gudiseva, Harini V; Kishaba, Kameron T; Suk, John J; Verma, Rohan; Tadimeti, Keerti; Thorson, John A; Ayyagari, Radha

    2017-02-01

    To test the utility of targeted sequencing as a method of clinical molecular testing in patients diagnosed with inherited retinal degeneration (IRD). After genetic counseling, peripheral blood was drawn from 188 probands and 36 carriers of IRD. Single gene testing was performed on each patient in a Clinical Laboratory Improvement Amendment (CLIA) certified laboratory. DNA was isolated, and all exons in the gene of interest were analyzed along with 20 base pairs of flanking intronic sequence. Genetic testing was most often performed on ABCA4, CTRP5, ELOV4, BEST1, CRB1, and PRPH2. Pathogenicity of novel sequence changes was predicted by PolyPhen2 and sorting intolerant from tolerant (SIFT). Of the 225 genetic tests performed, 150 were for recessive IRD, and 75 were for dominant IRD. A positive molecular diagnosis was made in 70 (59%) of probands with recessive IRD and 19 (26%) probands with dominant IRD. Analysis confirmed 12 (34%) of individuals as carriers of familial mutations associated with IRD. Thirty-two novel variants were identified; among these, 17 sequence changes in four genes were predicted to be possibly or probably damaging including: ABCA4 (14), BEST1 (2), PRPH2 (1), and TIMP3 (1). Targeted analysis of clinically suspected genes in 225 subjects resulted in a positive molecular diagnosis in 26% of patients with dominant IRD and 59% of patients with recessive IRD. Novel damaging mutations were identified in four genes. Single gene screening is not an ideal method for diagnostic testing given the phenotypic and genetic heterogeneity among IRD cases. High-throughput sequencing of all genes associated with retinal degeneration may be more efficient for molecular diagnosis.

  3. Tokamak physics experiment: Diagnostic windows study

    International Nuclear Information System (INIS)

    Merrigan, M.; Wurden, G.A.

    1995-11-01

    We detail the study of diagnostic windows and window thermal stress remediation in the long-pulse, high-power Tokamak Physics Experiment (TPX) operation. The operating environment of the TPX diagnostic windows is reviewed, thermal loads on the windows estimated, and cooling requirements for the windows considered. Applicable window-cooling technology from other fields is reviewed and its application to the TPX windows considered. Methods for TPX window thermal conditioning are recommended, with some discussion of potential implementation problems provided. Recommendations for further research and development work to ensure performance of windows in the TPX system are presented

  4. Design criteria of the bolometer diagnostic for steady-state operation of the W7-X stellarator

    International Nuclear Information System (INIS)

    Zhang, D.; Burhenn, R.; Koenig, R.; Giannone, L.; Grodzki, P. A.; Klein, B.; Grosser, K.; Baldzuhn, J.; Ewert, K.; Erckmann, V.; Hirsch, M.; Laqua, H. P.; Oosterbeek, J. W.

    2010-01-01

    A bolometric diagnostic system with features necessary for steady-state operation in the superconducting stellarator W7-X was designed. During a pulse length of 1800 s with an ECRH (electron cyclotron resonance heating) power of 10 MW, the components suffer not only from a large thermal load but also from stray radiation of the nonabsorbed isotropic microwaves. This paper gives an overview of the technical problems encountered during the design work and the solutions to individual problems to meet the special requirements in W7-X, e.g., component thermal protection, detector offset thermal drift suppression, as well as a microwave shielding technique.

  5. Design criteria of the bolometer diagnostic for steady-state operation of the W7-X stellaratora)

    Science.gov (United States)

    Zhang, D.; Burhenn, R.; Koenig, R.; Giannone, L.; Grodzki, P. A.; Klein, B.; Grosser, K.; Baldzuhn, J.; Ewert, K.; Erckmann, V.; Hirsch, M.; Laqua, H. P.; Oosterbeek, J. W.

    2010-10-01

    A bolometric diagnostic system with features necessary for steady-state operation in the superconducting stellarator W7-X was designed. During a pulse length of 1800 s with an ECRH (electron cyclotron resonance heating) power of 10 MW, the components suffer not only from a large thermal load but also from stray radiation of the nonabsorbed isotropic microwaves. This paper gives an overview of the technical problems encountered during the design work and the solutions to individual problems to meet the special requirements in W7-X, e.g., component thermal protection, detector offset thermal drift suppression, as well as a microwave shielding technique.

  6. The diagnostic odds ratio: a single indicator of test performance

    NARCIS (Netherlands)

    Glas, Afina S.; Lijmer, Jeroen G.; Prins, Martin H.; Bonsel, Gouke J.; Bossuyt, Patrick M. M.

    2003-01-01

    Diagnostic testing can be used to discriminate subjects with a target disorder from subjects without it. Several indicators of diagnostic performance have been proposed, such as sensitivity and specificity. Using paired indicators can be a disadvantage in comparing the performance of competing

  7. A Framework to Debug Diagnostic Matrices

    Science.gov (United States)

    Kodal, Anuradha; Robinson, Peter; Patterson-Hine, Ann

    2013-01-01

    Diagnostics is an important concept in system health and monitoring of space operations. Many of the existing diagnostic algorithms utilize system knowledge in the form of diagnostic matrix (D-matrix, also popularly known as diagnostic dictionary, fault signature matrix or reachability matrix) gleaned from physical models. But, sometimes, this may not be coherent to obtain high diagnostic performance. In such a case, it is important to modify this D-matrix based on knowledge obtained from other sources such as time-series data stream (simulated or maintenance data) within the context of a framework that includes the diagnostic/inference algorithm. A systematic and sequential update procedure, diagnostic modeling evaluator (DME) is proposed to modify D-matrix and wrapper logic considering least expensive solution first. This iterative procedure includes conditions ranging from modifying 0s and 1s in the matrix, or adding/removing the rows (failure sources) columns (tests). We will experiment this framework on datasets from DX challenge 2009.

  8. Operational evaluation of rapid diagnostic testing for Ebola Virus Disease in Guinean laboratories.

    Directory of Open Access Journals (Sweden)

    Amanda VanSteelandt

    Full Text Available Rapid Diagnostic Tests (RDTs for Ebola Virus Disease (EVD at the point of care have the potential to increase access and acceptability of EVD testing and the speed of patient isolation and secure burials for suspect cases. A pilot program for EVD RDTs in high risk areas of Guinea was introduced in October 2015. This paper presents concordance data between EVD RDTs and PCR testing in the field as well as an assessment of the acceptability, feasibility, and quality assurance of the RDT program.Concordance data were compiled from laboratory surveillance databases. The operational measures of the laboratory-based EVD RDT program were evaluated at all 34 sentinel sites in Guinea through: (1 a technical questionnaire filled by the lab technicians who performed the RDTs, (2 a checklist filled by the evaluator during the site visits, and (3 direct observation of the lab technicians performing the quality control test. Acceptability of the EVD RDT was good for technicians, patients, and families although many technicians (69.8% expressed concern for their safety while performing the test. The feasibility of the program was good based on average technician knowledge scores (6.6 out of 8 but basic infrastructure, equipment, and supplies were lacking. There was much room for improvement in quality assurance of the program.The implementation of new diagnostics in weak laboratory systems requires general training in quality assurance, biosafety and communication with patients in addition to specific training for the new test. Corresponding capacity building in terms of basic equipment and a long-term commitment to transfer supervision and quality improvement to national public health staff are necessary for successful implementation.

  9. The use of operator surveys by the CEGB to evaluate nuclear control room design and initiatives in the design of alarm systems and control room operating procedures

    International Nuclear Information System (INIS)

    Jackson, A.R.G.

    1988-01-01

    This paper reports on the use of operator surveys and trip report analysis methods which the Central Electricity Generating Board has developed to assess the extent and adequacy of operator support systems currently installed on its four twin-reactor, first generation Advanced Gas Cooled Reactor nuclear power plants. The survey consisted of a programme of structured interviews with control room engineers. The scope of the questions addressed; working environment, communications, man-machine interface, procedural information, and the diagnostic and predictive support system. The analysis of trip reports was targetted at identifying aspects of the performance of the operator support systems which might have been contributory to the cause of reactor trip. The results of this work are being used to assist in determining guidelines for the development of operator support systems, computerised controls and the structure of station operating procedures

  10. Multifunctional Nanocarriers for diagnostics, drug delivery and targeted treatment across blood-brain barrier: perspectives on tracking and neuroimaging

    Directory of Open Access Journals (Sweden)

    Estrada Giovani

    2010-03-01

    and hybrid contrast, such as fluorescent protein tomography and multispectral optoacoustic tomography. Overall, great potential is foreseen for nanocarriers in medical diagnostics, therapeutics and molecular targeting. A proposed roadmap for ongoing and future research directions is therefore discussed in detail with emphasis on the development of novel approaches for functionalization, targeting and imaging of nano-based drug delivery systems, a cutting-edge technology poised to change the ways medicine is administered.

  11. High-intensity laser diagnostics for OMEGA EP

    Energy Technology Data Exchange (ETDEWEB)

    Bromage, J.; Zuegel, J.D.; Bahk, S.W.; Vickery, D.S.; Waxer, L.J.; Irwin, D.; Bagnoud, V.; Boni, R.; Moore, M.D.; Jungquist, R.; Stoeckl, C. [Rochester Univ., Lab. for Laser Energetics, NY (United States)

    2006-06-15

    OMEGA EP (Extended Performance) is a new high-energy peta-watt laser system under construction at the University of Rochester's Laboratory for Laser Energetics. This paper describes our designs for two diagnostics critical to OMEGA EP's mission. The focal-spot diagnostic (FSD) is responsible for characterizing the focal spot of OMEGA EP's off-axis parabolic mirror at full energy. The ultrafast temporal diagnostic (UTD) is responsible for characterizing pulse shapes of full-energy target shots ranging in width from < 1 to 100 ps as well as setting the desired pulse width before the shot. These diagnostics will enable, for the first time, complete spatial and temporal characterization of the focus of a high-energy peta-watt laser at full energy. (authors)

  12. High-intensity laser diagnostics for OMEGA EP

    International Nuclear Information System (INIS)

    Bromage, J.; Zuegel, J.D.; Bahk, S.W.; Vickery, D.S.; Waxer, L.J.; Irwin, D.; Bagnoud, V.; Boni, R.; Moore, M.D.; Jungquist, R.; Stoeckl, C.

    2006-01-01

    OMEGA EP (Extended Performance) is a new high-energy peta-watt laser system under construction at the University of Rochester's Laboratory for Laser Energetics. This paper describes our designs for two diagnostics critical to OMEGA EP's mission. The focal-spot diagnostic (FSD) is responsible for characterizing the focal spot of OMEGA EP's off-axis parabolic mirror at full energy. The ultrafast temporal diagnostic (UTD) is responsible for characterizing pulse shapes of full-energy target shots ranging in width from < 1 to 100 ps as well as setting the desired pulse width before the shot. These diagnostics will enable, for the first time, complete spatial and temporal characterization of the focus of a high-energy peta-watt laser at full energy. (authors)

  13. Study for the design method of multi-agent diagnostic system to improve diagnostic performance for similar abnormality

    International Nuclear Information System (INIS)

    Minowa, Hirotsugu; Gofuku, Akio

    2014-01-01

    Accidents on industrial plants cause large loss on human, economic, social credibility. In recent, studies of diagnostic methods using techniques of machine learning such as support vector machine is expected to detect the occurrence of abnormality in a plant early and correctly. There were reported that these diagnostic machines has high accuracy to diagnose the operating state of industrial plant under mono abnormality occurrence. But the each diagnostic machine on the multi-agent diagnostic system may misdiagnose similar abnormalities as a same abnormality if abnormalities to diagnose increases. That causes that a single diagnostic machine may show higher diagnostic performance than one of multi-agent diagnostic system because decision-making considering with misdiagnosis is difficult. Therefore, we study the design method for multi-agent diagnostic system to diagnose similar abnormality correctly. This method aimed to realize automatic generation of diagnostic system where the generation process and location of diagnostic machines are optimized to diagnose correctly the similar abnormalities which are evaluated from the similarity of process signals by statistical method. This paper explains our design method and reports the result evaluated our method applied to the process data of the fast-breeder reactor Monju

  14. Using the Nova target chamber for high-yield targets

    International Nuclear Information System (INIS)

    Pitts, J.H.

    1987-01-01

    The existing 2.2-m-radius Nova aluminum target chamber, coated and lined with boron-seeded carbon shields, is proposed for use with 1000-MJ-yield targets in the next laser facility. The laser beam and diagnostic holes in the target chamber are left open and the desired 10 -2 Torr vacuum is maintained both inside and outside the target chamber; a larger target chamber room is the vacuum barrier to the atmosphere. The hole area available is three times that necessary to maintain a maximum fluence below 12 J/cm 2 on optics placed at a radius of 10 m. Maximum stress in the target chamber wall is 73 MPa, which complies with the intent of the ASME Pressure Vessel Code. However, shock waves passing through the inner carbon shield could cause it to comminute. We propose tests and analyses to ensure that the inner carbon shield survives the environment. 13 refs

  15. Software diagnostic aids on Aladdin

    International Nuclear Information System (INIS)

    Eisert, D.E.; Stott, J.P.

    1990-01-01

    The upgrade of the Aladdin control system included many enhancements in the software. Some of the new diagnostic aids provided are: intelligent temporary logging of all readbacks for at least the previous 12 hours, permanent logging of specified readbacks into disk files, temporary logging of beam positions at an operator-specified interval, an alarm system for all devices, including range limits for analogue readbacks that should remain fixed and window limits which automatically track readbacks that should decay or increase monotonically, automated checklists to verify the devices are within the specified operating range for a particular phase of operation, latched digital signals to capture momentary changes. The software has been designed to alert the operator when something is wrong, without generating a flood of unimportant messages, and to make it possible to observe and record readbacks over a range of time scales. The latter capability is essential for tracking down marginal components and correlating observed problems with possible causes. The algorithms used for these diagnostic aids, and how well they perform their desired tasks, are described in this paper. (orig.)

  16. Calibration issues for neutron diagnostics

    International Nuclear Information System (INIS)

    Sadler, G.J.; Adams, J.M.; Barnes, C.W.

    1997-10-01

    In order for ITER to meet its operational and programmatic goals, it will be necessary to measure a wide range of plasma parameters. Some of the required parameters e.g., neutron yield, fusion power and power density, ion temperature profile in the core plasma, and characteristics of confined and escaping alpha particle populations are best measured by fusion product diagnostic techniques. To make these measurements, ITER will have dedicated diagnostic systems, including radial and vertical neutron cameras, neutron and gamma ray spectrometers, internal and external fission chambers, a neutron activation system, and diagnostics for confined and escaping alpha particles. Engineering integration of many of these systems is in progress, and other systems are under investigation. This paper summarizes the present state of design of fusion product diagnostic systems for ITER and discusses expected measurement capability

  17. X-ray diagnostics in the laser-initiated fusion program

    International Nuclear Information System (INIS)

    Godwin, R.P.

    1975-08-01

    The high-density and high-temperature plasma conditions required for successful laser-initiated fusion make x-ray diagnostics a valuable tool in this exciting field. Measurements of the hard x-ray continuum emitted from laser targets provide insight into the complex laser-plasma coupling physics and the consequent energy transport through the bremsstrahlung signature of energetic electrons. X-ray techniques are important in the selection and assay of microballoon targets for current compression experiments. X-ray imaging experiments and diffraction spectroscopy of highly stripped atoms can provide information upon the symmetry, density and temperature of laser targets. Extremely high temporal and spatial resolution may be required for definitive diagnostic information on compressed targets. While laser-produced plasmas are interesting as possible intense x-ray sources and as a possible means of achieving x-ray lasing, those topics are outside the scope of this review. (auth)

  18. Evaluation of the optimal diagnostic criteria for regional lymph node metastases of lung cancer on MR imaging by receiver operating characteristic curve

    International Nuclear Information System (INIS)

    Iwai, Naomichi; Yamaguchi, Yutaka

    1991-01-01

    MRI was performed in 78 primary lung cancer cases to evaluate the optimal diagnostic criteria for regional lymph node metastases. Receiver operating characteristic (ROC) curve analysis for 262 lymph nodes of the hilar and mediastinal regions showed that the optimal size criterion is 10 mm in the mean axis of nodal diameter. Employing this criterion, the diagnostic rates for hilar and mediastinal lymph nodes had a sensitivity of 75%, a specificity of 82%, and an overall accuracy of 79%. However, the diagnostic rates for subaortic, paraaortic, and hilar lymph nodes using the same criterion showed lower specificities than those for other nodes. It was suggested that evaluation by coronal section made the diagnosis for subaortic lymph nodes more precise. In the ROC curve analysis for each histologic type, it was thought that the optimal criterion for adenocarcinoma was 10 mm in the mean axis, and that the criteria for squamous cell carcinoma were 11 mm in the mean axis and 10 mm in the sort axis. (author)

  19. Dementia diagnosis and post-diagnostic support in Scottish rural communities: experiences of people with dementia and their families.

    Science.gov (United States)

    Innes, Anthea; Szymczynska, Paulina; Stark, Cameron

    2014-03-01

    This paper explores the reported difficulties and satisfactions with diagnostic processes and post-diagnostic support offered to people with dementia and their families living in the largest remote and rural region in Scotland. A consultation with 18 participants, six people with dementia and 12 family members, was held using semi-structured interviews between September and November 2010. Three points in the diagnostic process were explored: events and experiences pre-diagnosis; the experience of the diagnostic process; and post-diagnostic support. Experiences of people with dementia and their carers varied at all three points in the diagnostic process. Participant experiences in this study suggest greater efforts are required to meet Government diagnosis targets and that post-diagnostic support needs to be developed and monitored to ensure that once a diagnosis is given people are well-supported. Without post-diagnostic provision Government targets for diagnosis are just that, quota targets, rather than a means to improve service experiences.

  20. Lithium Battery Transient Response as a Diagnostic Tool

    Science.gov (United States)

    Denisov, E.; Nigmatullin, R.; Evdokimov, Y.; Timergalina, G.

    2018-05-01

    Lithium batteries are currently used as the main energy storage for electronic devices. Progress in the field of portable electronic devices is significantly determined by the improvement of their weight/dimensional characteristics and specific capacity. In addition to the high reliability required of lithium batteries, in some critical applications proper diagnostics are required. Corresponding techniques allow prediction and prevention of operation interruption and avoidance of expensive battery replacement, and also provide additional benefits. Many effective diagnostic methods have been suggested; however, most of them require expensive experimental equipment, as well as interruption or strong perturbation of the operating mode. In the framework of this investigation, a simple diagnostic method based on analysis of transient processes is proposed. The transient response is considered as a reaction to an applied load variation that typically corresponds to normal operating conditions for most real applications. The transient response contains the same information as the impedance characteristic for the system operating in linear mode. Taking into account the large number of publications describing the impedance response associated with diagnostic methods, it can be assumed that the transient response contains a sufficient amount of information for creation of effective diagnostic systems. The proposed experimental installation is based on a controlled load, providing current variation, measuring equipment, and data processing electronics. It is proposed to use the second exponent parameters U 2 and β to estimate the state of charge for secondary lithium batteries. The proposed method improves the accuracy and reliability of a set of quantitative parameters associated with electrochemical energy sources.

  1. Diagnostics in the hostile environments of a prototype fusion reactor

    International Nuclear Information System (INIS)

    Osher, J.E.

    1982-01-01

    Various facets of a thermonuclear type plasma that will likely require special considerations or hardening of applied diagnostic instrumentation are reviewed. The discussion will include both on-line diagnostic instrumentation requirements for satisfactory operation and considerations to reduce integrated radiation damage sufficiently for a reasonable diagnostic lifetime. Several new diagnostics aimed specifically at measurements of the plasma characteristics most appropriate to a thermonculear reactor type plasma are discussed. This will include instrumentation needed to make quantitative energy flow measurements during long term operation with the expected high input power sources, and locally very high wall power loadings. The second part of this lecture will broaden diagnostics to include materials damage measurements needed for engineering design studies. This will include needed diagnostic instrumentation to assess first wall damage, sputtering erosion at walls (and high power beam dumps), and radiation damage to components such as insulators

  2. Power reactors operational diagnosis

    International Nuclear Information System (INIS)

    Dach, K.; Pecinka, L.

    1976-01-01

    The definition of reactor operational diagnostics is presented and the fundamental trends of research are determined. The possible sources of power reactor malfunctions, the methods of defect detection, the data evaluation and the analysis of the results are discussed in detail. In view of scarcity of a theoretical basis and of insufficient in-core instrumentation, operational diagnostics cannot be as yet incorporated in a computer-aided reactor control system. (author)

  3. Laser performance operations model (LPOM): a computational system that automates the setup and performance analysis of the national ignition facility

    Energy Technology Data Exchange (ETDEWEB)

    Shaw, M; House, R; Williams, W; Haynam, C; White, R; Orth, C; Sacks, R [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA, 94550 (United States)], E-mail: shaw7@llnl.gov

    2008-05-15

    The National Ignition Facility (NIF) is a stadium-sized facility containing a 192-beam, 1.8 MJ, 500-TW, 351-nm laser system together with a 10-m diameter target chamber with room for many target diagnostics. NIF will be the world's largest laser experimental system, providing a national center to study inertial confinement fusion and the physics of matter at extreme energy densities and pressures. A computational system, the Laser Performance Operations Model (LPOM) has been developed and deployed that automates the laser setup process, and accurately predict laser energetics. LPOM determines the settings of the injection laser system required to achieve the desired main laser output, provides equipment protection, determines the diagnostic setup, and supplies post shot data analysis and reporting.

  4. Design and integration of lower ports for ITER diagnostic systems

    Energy Technology Data Exchange (ETDEWEB)

    Casal, Natalia, E-mail: Natalia.casal@iter.org [ITER Organization, Route de Vinon-sur-Verdon – CS 90 046 – 13067 St Paul Lez Durance Cedex (France); Bertalot, Luciano; Cheng, Hao; Drevon, Jean Marc; Duckworth, Philip; Giacomin, Thibaud; Guirao, Julio; Iglesias, Silvia [ITER Organization, Route de Vinon-sur-Verdon – CS 90 046 – 13067 St Paul Lez Durance Cedex (France); Kochergin, Mikhail [IOFFE Institute, Saint Petersburg (Russian Federation); Martin, Alex [ITER Organization, Route de Vinon-sur-Verdon – CS 90 046 – 13067 St Paul Lez Durance Cedex (France); McCarron, Eddie [Oxford Technologies Ltd., Abingdon (United Kingdom); Mokeev, Alexander [Russian Federation Domestic Agency, Moscow (Russian Federation); Mota, Fernando [CIEMAT, Madrid (Spain); Penot, Christophe; Portales, Mickael [ITER Organization, Route de Vinon-sur-Verdon – CS 90 046 – 13067 St Paul Lez Durance Cedex (France); Kitazawa, Sin-iti [Japanese Domestic Agency, Naka (Japan); Sky, Jack [Oxford Technologies Ltd., Abingdon (United Kingdom); Suarez, Alejandro; Udintsev, Victor; Utin, Yuri [ITER Organization, Route de Vinon-sur-Verdon – CS 90 046 – 13067 St Paul Lez Durance Cedex (France); and others

    2015-10-15

    Highlights: • Lower port structures are in its conceptual design phase. • Electromagnetic and seismic loads, will dominate all other mechanical loads. • Design allows diagnostics support, neutron shielding while and signals transmission. • Installation and maintenance operations are fully remote handling compatible. - Abstract: All around the ITER vacuum vessel, forty-four ports will provide access to the vacuum vessel for remote handling operations, diagnostic systems, heating, and vacuum systems: 18 upper ports, 17 equatorial ports, and 9 lower ports. Among the lower ports, three of them will be used for the remote handling installation of the ITER divertor. Once the divertor is in place, these ports will host various diagnostic systems mounted in the so-called diagnostic racks. The diagnostic racks must allow the support and cooling of the diagnostics, extraction of the required diagnostic signals, and providing access and maintainability while minimizing the leakage of radiation toward the back of the port where the humans are allowed to enter. A fully integrated inner rack, carrying the near plasma diagnostic components, will be an stainless steel structure, 4.2 m long, with a maximum weight of 10 t. This structure brings water for cooling and baking at maximum temperature of 240 °C and provides connection with gas, vacuum and electric services. Additional racks (placed away from plasma and not requiring cooling) may be required for the support of some particular diagnostic components. The diagnostics racks and its associated ex vessel structures, which are in its conceptual design phase, are being designed to survive the lifetime of ITER of 20 years. This paper presents the current state of development including interfaces, diagnostic integration, operation and maintenance, shielding requirements, remote handling, loads cases and discussion of the main challenges coming from the severe environment and engineering requirements.

  5. Measuring diagnostic and predictive accuracy in disease management: an introduction to receiver operating characteristic (ROC) analysis.

    Science.gov (United States)

    Linden, Ariel

    2006-04-01

    Diagnostic or predictive accuracy concerns are common in all phases of a disease management (DM) programme, and ultimately play an influential role in the assessment of programme effectiveness. Areas, such as the identification of diseased patients, predictive modelling of future health status and costs and risk stratification, are just a few of the domains in which assessment of accuracy is beneficial, if not critical. The most commonly used analytical model for this purpose is the standard 2 x 2 table method in which sensitivity and specificity are calculated. However, there are several limitations to this approach, including the reliance on a single defined criterion or cut-off for determining a true-positive result, use of non-standardized measurement instruments and sensitivity to outcome prevalence. This paper introduces the receiver operator characteristic (ROC) analysis as a more appropriate and useful technique for assessing diagnostic and predictive accuracy in DM. Its advantages include; testing accuracy across the entire range of scores and thereby not requiring a predetermined cut-off point, easily examined visual and statistical comparisons across tests or scores, and independence from outcome prevalence. Therefore the implementation of ROC as an evaluation tool should be strongly considered in the various phases of a DM programme.

  6. Laser fusion diagnostics

    International Nuclear Information System (INIS)

    Coleman, L.W.

    1978-01-01

    The current status of the capability of laser fusion diagnostics is reviewed. Optical and infrared streak cameras provide one time resolution measurement capability of less than 10 ps, while x-ray streak cameras provide 15 ps time resolution in the range of about 1--30 keV presently. Time integrated spatial resolutions of 1 μm are provided with a variety of optical techniques. Ultraviolet holographic interferometry has measured electron densities above 10 21 cm -3 with 1 μm spatial resolution and 15 ps temporal resolution. X-ray microscopes provide 3 μm time integrated resolution and the x-ray streak pinhole camera has 6 μm spatial resolution. Development of the framing camera has thus far provided 50 μm spatial resolution with 125 ps frame duration and the third order reconstruction of zone plate images has provided 3 μm resolutions for alpha particles. Time integrated measurements of x-rays span the range shown. Finally, the new Shiva neutron spectrometer increases the energy resolution capability of that technique to 25 keV for 14-MeV neutrons. These combined capabilities provide a unique set of diagnostics for the detailed measurement of the interaction of laser light with targets and a subsequent performance of those targets

  7. Advance in study of intelligent diagnostic method for nuclear power plant

    International Nuclear Information System (INIS)

    Zhou Gang; Yang Li

    2008-01-01

    The advance of research on the application of three types of intelligent diagnostic approach based on neural network (ANN), fuzzy logic and expert system to the operation status monitoring and fault diagnosis of nuclear power plant (NPP) was reviewed. The research status and characters on status monitoring and fault diagnosis approaches based on neural network, fuzzy logic and expert system for nuclear power plant were analyzed. The development trend of applied research on intelligent diagnostic approaches for nuclear power plant was explored. The analysis results show that the research achievements on intelligent diagnostic approaches based on fuzzy logic and expert system for nuclear power plant are not much relatively. The research of intelligent diagnostic approaches for nuclear power plant concentrate on the aspect of operation status monitoring and fault diagnosis based on neural networks for nuclear power plant. The advancing tendency of intelligent diagnostic approaches for nuclear power plant is the combination of various intelligent diagnostic approaches, the combination of neural network diagnostic approaches and other diagnostic approaches as well as multiple neural network diagnostic approaches. (authors)

  8. X-ray diffraction diagnostic design for the National Ignition Facility

    Science.gov (United States)

    Ahmed, Maryum F.; House, Allen; Smith, R. F.; Ayers, Jay; Lamb, Zachary S.; Swift, David W.

    2013-09-01

    This paper describes the design considerations for Target Diffraction In-Situ (TARDIS), an x-ray diffraction diagnostic at the National Ignition Facility. A crystal sample is ramp-compressed to peak pressures between 10 and 30 Mbar and, during a pressure hold period, is probed with quasi-monochromatic x-rays emanating from a backlighter source foil. The crystal spectrography diffraction lines are recorded onto image plates. The crystal sample, filter, and image plates are packaged into one assembly, allowing for accurate and repeatable target to image plate registration. Unconverted laser light impinges upon the device, generating debris, the effects of which have been mitigated. Dimpled blast shields, high strength steel alloy, and high-z tungsten are used to shield and protect the image plates. A tapered opening was designed to provide adequate thickness of shielding materials without blocking the drive beams or x-ray source from reaching the crystal target. The high strength steel unit serves as a mount for the crystal target and x-ray source foil. A tungsten body contains the imaging components. Inside this sub-assembly, there are three image plates: a 160 degree field of view curved plate directly opposite the target opening and two flat plates for the top and bottom. A polycarbonate frame, coated with the appropriate filter material and embedded with registration features for image plate location, is inserted into the diagnostic body. The target assembly is metrologized and then the diagnostic assembly is attached.

  9. Media Smart-Targeted: Diagnostic outcomes from a two-country pragmatic online eating disorder risk reduction trial for young adults.

    Science.gov (United States)

    Wilksch, Simon M; O'Shea, Anne; Wade, Tracey D

    2018-03-01

    Diagnostic outcomes in eating disorder (ED) risk reduction trials are important but rarely reported. An online pragmatic randomized-controlled trial was conducted with young-adult women in Australia and New Zealand seeking to improve their body image. Media Smart-Targeted (MS-T) was a 9-module program released weekly while control participants received tips for positive body image. Eating Disorder Examination-Questionnaire (EDE-Q) scores from baseline and 12-month follow-up were used to investigate two outcomes: ED onset in those who were asymptomatic at baseline (prevention effects); and, ED remission in those who met diagnosis at baseline (treatment effects). MS-T participants were 66% less likely than controls to develop an ED by 12-month follow-up (nonsignificant). MS-T participants who met ED criteria at baseline were 75% less likely than controls to still meet diagnostic criteria at follow-up. This effect was significant and remained so for both those who did and who did not access external face-to-face ED treatment during the trial. While further investigations are necessary, MS-T has fully automated procedures, low implementation costs, the potential to be delivered at-scale to assist those assist those where face-to-face services are limited or not available (e.g., remote areas). © 2018 Wiley Periodicals, Inc.

  10. Outer Membrane Protein A Conservation among Orientia tsutsugamushi Isolates Suggests Its Potential as a Protective Antigen and Diagnostic Target

    Directory of Open Access Journals (Sweden)

    Sean M. Evans

    2018-06-01

    Full Text Available Scrub typhus threatens one billion people in the Asia-Pacific area and cases have emerged outside this region. It is caused by infection with any of the multitude of strains of the bacterium Orientia tsutsugamushi. A vaccine that affords heterologous protection and a commercially-available molecular diagnostic assay are lacking. Herein, we determined that the nucleotide and translated amino acid sequences of outer membrane protein A (OmpA are highly conserved among 51 O. tsutsugamushi isolates. Molecular modeling revealed the predicted tertiary structure of O. tsutsugamushi OmpA to be very similar to that of the phylogenetically-related pathogen, Anaplasma phagocytophilum, including the location of a helix that contains residues functionally essential for A. phagocytophilum infection. PCR primers were developed that amplified ompA DNA from all O. tsutsugamushi strains, but not from negative control bacteria. Using these primers in quantitative PCR enabled sensitive detection and quantitation of O. tsutsugamushi ompA DNA from organs and blood of mice that had been experimentally infected with the Karp or Gilliam strains. The high degree of OmpA conservation among O. tsutsugamushi strains evidences its potential to serve as a molecular diagnostic target and justifies its consideration as a candidate for developing a broadly-protective scrub typhus vaccine.

  11. Diagnostic value of adenosine deaminase in ascites for tuberculosis ascites: a meta-analysis.

    Science.gov (United States)

    Tao, Lin; Ning, Hong-Jian; Nie, Hai-Ming; Guo, Xiao-Yun; Qin, Shan-Yu; Jiang, Hai-Xing

    2014-05-01

    The diagnosis of tuberculosis (TB) ascites using standard diagnostic tools is difficult. The aim of the present meta-analysis was to establish the overall diagnostic accuracy of adenosine deaminase (ADA) levels in ascites for diagnosing TB ascites. A systematic review was performed of English language publications prior to April 2013. Sensitivity, specificity, and other measures of the accuracy of ADA for the diagnosis of TB ascites using ascites fluid were summarized using a random-effects model or a fixed-effects model. Receiver operating characteristic curves were used to summarize overall test performance. Seventeen studies involving 1797 subjects were eligible for the analysis. The summary estimates of sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, and the area under cure of overall analysis were: 0.93, 0.94, 13.55, 0.11, 169.83, and 0.976, respectively; the results of sensitivity analysis of studies that used Giusti method were 0.94, 0.94, 12.99, 0.08, 183.18, and 0.977, respectively. Our results suggest that ADA in the ascites can be a sensitive and specific target and a critical criterion for the diagnosis of TB ascites. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Molecular diagnostics for human leptospirosis.

    Science.gov (United States)

    Waggoner, Jesse J; Pinsky, Benjamin A

    2016-10-01

    The definitive diagnosis of leptospirosis, which results from infection with spirochetes of the genus Leptospira, currently relies on the use of culture, serological testing (microscopic agglutination testing), and molecular detection. The purpose of this review is to describe new molecular diagnostics for Leptospira and discuss advancements in the use of available methods. Efforts have been focused on improving the clinical sensitivity of Leptospira detection using molecular methods. In this review, we describe a reoptimized pathogenic species-specific real-time PCR (targeting lipL32) that has demonstrated improved sensitivity, findings by two groups that real-time reverse-transcription PCR assays targeting the 16S rrs gene can improve detection, and two new loop-mediated amplification techniques. Quantitation of leptospiremia, detection in different specimen types, and the complementary roles played by molecular detection and microscopic agglutination testing will be discussed. Finally, a protocol for Leptospira strain subtyping using variable number tandem repeat targets and high-resolution melting will be described. Molecular diagnostics have an established role for the diagnosis of leptospirosis and provide an actionable diagnosis in the acute setting. The use of real-time reverse-transcription PCR for testing serum/plasma and cerebrospinal fluid, when available, may improve the detection of Leptospira without decreasing clinical specificity.

  13. Low activation diagnostic equipment design studies

    International Nuclear Information System (INIS)

    Hopkins, G.R.; Cheng, E.T.; Fisher, R.K.

    1985-01-01

    The low activation fusion concept has been applied to the diagnostic equipment in a fusion reactor. The components where fabrication from low activation materials is feasible have been identified. Other systems where higher activation elements are required can have their activation reduced by design approaches which include shielding and operation only in low flux regions of the reactor. Some components will not operate in a high flux so activation is not a major concern. This low activation diagnostic equipment study completes a series of low activation studies where all the components in a fusion power reactor have now been evaluated. It is concluded that a completely low activation fusion reactor is feasible with all components meeting the functional requirements. This provides an environmentally benign energy source with a high confidence level in meeting safety criteria in operation, maintenance and waste disposal

  14. A preface on advances in diagnostics for infectious and parasitic diseases: detecting parasites of medical and veterinary importance.

    Science.gov (United States)

    Stothard, J Russell; Adams, Emily

    2014-12-01

    There are many reasons why detection of parasites of medical and veterinary importance is vital and where novel diagnostic and surveillance tools are required. From a medical perspective alone, these originate from a desire for better clinical management and rational use of medications. Diagnosis can be at the individual-level, at close to patient settings in testing a clinical suspicion or at the community-level, perhaps in front of a computer screen, in classification of endemic areas and devising appropriate control interventions. Thus diagnostics for parasitic diseases has a broad remit as parasites are not only tied with their definitive hosts but also in some cases with their vectors/intermediate hosts. Application of current diagnostic tools and decision algorithms in sustaining control programmes, or in elimination settings, can be problematic and even ill-fitting. For example in resource-limited settings, are current diagnostic tools sufficiently robust for operational use at scale or are they confounded by on-the-ground realities; are the diagnostic algorithms underlying public health interventions always understood and well-received within communities which are targeted for control? Within this Special Issue (SI) covering a variety of diseases and diagnostic settings some answers are forthcoming. An important theme, however, throughout the SI is to acknowledge that cross-talk and continuous feedback between development and application of diagnostic tests is crucial if they are to be used effectively and appropriately.

  15. Resilient actions in the diagnostic process and system performance.

    Science.gov (United States)

    Smith, Michael W; Davis Giardina, Traber; Murphy, Daniel R; Laxmisan, Archana; Singh, Hardeep

    2013-12-01

    Systemic issues can adversely affect the diagnostic process. Many system-related barriers can be masked by 'resilient' actions of frontline providers (ie, actions supporting the safe delivery of care in the presence of pressures that the system cannot readily adapt to). We explored system barriers and resilient actions of primary care providers (PCPs) in the diagnostic evaluation of cancer. We conducted a secondary data analysis of interviews of PCPs involved in diagnostic evaluation of 29 lung and colorectal cancer cases. Cases covered a range of diagnostic timeliness and were analysed to identify barriers for rapid diagnostic evaluation, and PCPs' actions involving elements of resilience addressing those barriers. We rated these actions according to whether they were usual or extraordinary for typical PCP work. Resilient actions and associated barriers were found in 59% of the cases, in all ranges of timeliness, with 40% involving actions rated as beyond typical. Most of the barriers were related to access to specialty services and coordination with patients. Many of the resilient actions involved using additional communication channels to solicit cooperation from other participants in the diagnostic process. Diagnostic evaluation of cancer involves several resilient actions by PCPs targeted at system deficiencies. PCPs' actions can sometimes mitigate system barriers to diagnosis, and thereby impact the sensitivity of 'downstream' measures (eg, delays) in detecting barriers. While resilient actions might enable providers to mitigate system deficiencies in the short run, they can be resource intensive and potentially unsustainable. They complement, rather than substitute for, structural remedies to improve system performance. Measures to detect and fix system performance issues targeted by these resilient actions could facilitate diagnostic safety.

  16. A Survey On Mean Glandular Dose From Full-Field Digital Mammography Systems, Operate Using Mo/ Mo And W/Rh Target/ Filter Combinations

    International Nuclear Information System (INIS)

    Noriah Jamal; Siti Selina Abdul Hamid; Humairah Samad Cheung; Siti Kamariah Che Mohamed; Ellyda Muhammed Nordin; Radhiana Hassan; Rehir Dahalan

    2013-01-01

    We had conducted a survey on Mean Glandular Dose (MGD) from Full-Field Digital Mammography systems (FFDM) operate using Molybdenum/ Molybdenum (Mo/ Mo) and Tungsten/ Rhodium (W/ Rh) target/ filter combinations. A survey was carried out at two randomly selected mammography centres in Malaysia, namely National Cancer Society and International Islamic University of Malaysia. The first centre operates using a W/ Rh, while the second centre operates using an Mo/ Mo target/ filter combinations. On the basis of recorded information, data on mammographic views, MGD, age and Compressed Breast Thickness (CBT) were recorded for 100 patients, for each mammographic centre respectively. The MGD data were analyzed for variation with age group, with 5 years increment. The MGD data were also analyzed for variation with CBT, with 5 mm increment. We found that for both CC and MLO views, FFDM systems operated using Mo/ Mo and W/ Rh target/ filter combinations present the same trend on MGD. The average MGD decreases as age increases. While average MGD increases with the increasing of CBT. However, FFDM system operates using Mo/ Mo gives higher MGD as compared with FFDM system operates using W/ Rh. (author)

  17. Progress in diagnostics of the COMPASS tokamak

    Science.gov (United States)

    Weinzettl, V.; Adamek, J.; Berta, M.; Bilkova, P.; Bogar, O.; Bohm, P.; Cavalier, J.; Dejarnac, R.; Dimitrova, M.; Ficker, O.; Fridrich, D.; Grover, O.; Hacek, P.; Havlicek, J.; Havranek, A.; Horacek, J.; Hron, M.; Imrisek, M.; Komm, M.; Kovarik, K.; Krbec, J.; Markovic, T.; Matveeva, E.; Mitosinkova, K.; Mlynar, J.; Naydenkova, D.; Panek, R.; Paprok, R.; Peterka, M.; Podolnik, A.; Seidl, J.; Sos, M.; Stockel, J.; Tomes, M.; Varavin, M.; Varju, J.; Vlainic, M.; Vondracek, P.; Zajac, J.; Zacek, F.; Stano, M.; Anda, G.; Dunai, D.; Krizsanoczi, T.; Refy, D.; Zoletnik, S.; Silva, A.; Gomes, R.; Pereira, T.; Popov, Tsv.; Sarychev, D.; Ermak, G. P.; Zebrowski, J.; Jakubowski, M.; Rabinski, M.; Malinowski, K.; Nanobashvili, S.; Spolaore, M.; Vianello, N.; Gauthier, E.; Gunn, J. P.; Devitre, A.

    2017-12-01

    The COMPASS tokamak at IPP Prague is a small-size device with an ITER-relevant plasma geometry and operating in both the Ohmic as well as neutral beam assisted H-modes since 2012. A basic set of diagnostics installed at the beginning of the COMPASS operation has been gradually broadened in type of diagnostics, extended in number of detectors and collected channels and improved by an increased data acquisition speed. In recent years, a significant progress in diagnostic development has been motivated by the improved COMPASS plasma performance and broadening of its scientific programme (L-H transition and pedestal scaling studies, magnetic perturbations, runaway electron control and mitigation, plasma-surface interaction and corresponding heat fluxes, Alfvenic and edge localized mode observations, disruptions, etc.). In this contribution, we describe major upgrades of a broad spectrum of the COMPASS diagnostics and discuss their potential for physical studies. In particular, scrape-off layer plasma diagnostics will be represented by a new concept for microsecond electron temperature and heat flux measurements - we introduce a new set of divertor Langmuir and ball-pen probe arrays, newly constructed probe heads for reciprocating manipulators as well as several types of standalone probes. Among optical tools, an upgraded high-resolution edge Thomson scattering diagnostic for pedestal studies and a set of new visible light and infrared (plasma-surface interaction investigations) cameras will be described. Particle and beam diagnostics will be covered by a neutral particle analyzer, diagnostics on a lithium beam, Cherenkov detectors (for a direct detection of runaway electrons) and neutron detectors. We also present new modifications of the microwave reflectometer for fast edge density profile measurements.

  18. Deposition Diagnostics for Next-step Devices

    International Nuclear Information System (INIS)

    Skinner, C.H.; Roquemore, A.L.; Bader, A.; Wampler, W.R.

    2004-01-01

    The scale-up of deposition in next-step devices such as ITER will pose new diagnostic challenges. Codeposition of hydrogen with carbon needs to be characterized and understood in the initial hydrogen phase in order to mitigate tritium retention and qualify carbon plasma facing components for DT operations. Plasma facing diagnostic mirrors will experience deposition that is expected to rapidly degrade their reflectivity, posing a new challenge to diagnostic design. Some eroded particles will collect as dust on interior surfaces and the quantity of dust will be strictly regulated for safety reasons - however diagnostics of in-vessel dust are lacking. We report results from two diagnostics that relate to these issues. Measurements of deposition on NSTX with 4 Hz time resolution have been made using a quartz microbalance in a configuration that mimics that of a typical diagnostic mirror. Often deposition was observed immediately following the discharge suggesting that diagnostic shutters should be closed as soon as possible after the time period of interest. Material loss was observed following a few discharges. A novel diagnostic to detect surface particles on remote surfaces was commissioned on NSTX

  19. MCNPX simulations of fast neutron diagnostics for accelerator-driven systems

    Energy Technology Data Exchange (ETDEWEB)

    Habob, Moinul

    2005-12-15

    In accelerator-driven systems, the neutron spectrum will extend all the way up to the incident beam energy, i.e., several hundred MeV or even up to GeV energies. The high neutron energy allows novel diagnostics with a set of measurement techniques that can be used in a sub-critical reactor environment. Such measurements are primarily connected to system safety and validation. This report shows that in-core fast-neutron diagnostics can be employed to monitor changes in the position of incidence of the primary proton beam onto the neutron production target. It has also been shown that fast neutrons can be used to detect temperature-dependent density changes in a liquid lead-bismuth target. Fast neutrons can escape the system via the beam pipe for the incident proton beam. Out-of-core monitoring of these so called back-streaming neutrons could potentially be used to monitor beam changes if the target has a suitable shape. Moreover, diagnostics of back-streaming neutrons might be used for validation of the system design.

  20. MCNPX simulations of fast neutron diagnostics for accelerator-driven systems

    International Nuclear Information System (INIS)

    Habib, Moinul

    2005-12-01

    In accelerator-driven systems, the neutron spectrum will extend all the way up to the incident beam energy, i.e., several hundred MeV or even up to GeV energies. The high neutron energy allows novel diagnostics with a set of measurement techniques that can be used in a sub-critical reactor environment. Such measurements are primarily connected to system safety and validation. This report shows that in-core fast-neutron diagnostics can be employed to monitor changes in the position of incidence of the primary proton beam onto the neutron production target. It has also been shown that fast neutrons can be used to detect temperature-dependent density changes in a liquid lead-bismuth target. Fast neutrons can escape the system via the beam pipe for the incident proton beam. Out-of-core monitoring of these so called back-streaming neutrons could potentially be used to monitor beam changes if the target has a suitable shape. Moreover, diagnostics of back-streaming neutrons might be used for validation of the system design

  1. Performance diagnostic system for emergency diesel generators

    International Nuclear Information System (INIS)

    Logan, K.P.

    1991-01-01

    Diesel generators are commonly used for emergency backup power at nuclear stations. Emergency diesel generators (EDGs) are subject to both start-up and operating failures, due to infrequent and fast-start use. EDG reliability can be critical to plant safety, particularly when station blackout occurs. This paper describes an expert diagnostic system designed to consistently evaluate the operating performance of diesel generators. The prototype system is comprised of a suite of sensor monitoring, cylinder combustion analyzing, and diagnostic workstation computers. On-demand assessments of generator and auxiliary equipment performance are provided along with color trend displays comparing measured performance to reference-normal conditions

  2. In-operation diagnostic system for reactor coolant pump

    International Nuclear Information System (INIS)

    Sugiyama, Mitsunobu; Hasegawa, Ichiro; Kitahara, Hiromichi; Shimamura, Kazuo; Yasuda, Chiaki; Ikeda, Yasuhiro; Kida, Yasuo.

    1996-01-01

    A reactor coolant pump (RCP) is one of the most important rotating machines in the primary loop nuclear power plants. To improve the reliability and of nuclear power plants, a new diagnostic system that enables early detection of RCP faults has been developed. This system is based on continuous monitoring of vibration and other process data. Vibration is an important indicator of mechanical faults providing information on physical phenomena such as changes in dynamic characteristics and excitation forces changes that signal failure or incipient failure. This new system features comparative vibration analysis and simulation to anticipate equipment failure. (author)

  3. Technology Issues of Burning Plasma Diagnostics

    International Nuclear Information System (INIS)

    Kaye, A. S.

    2008-01-01

    The ITER Tokamak will require many diagnostics both for safe and reliable operation of the machine and for understanding of the physics underlying the performance. The design of these diagnostics raises many challenging technical issues not faced on smaller machines. These arise partly from the increase demands on established diagnostics arising from the increased size, higher magnetic field, large heating power, and in particular the dramatically longer pulse duration of ITER, which make issue such as power loading on first wall components more challenging. The demands on reliability and availability of the machine in order to achieve the objectives within the agreed time schedule also place severe additional demands on the design, quality assurance and maintainability of diagnostics. ITER will produce many orders of magnitude more neutrons than previous Tokamaks and will be a licensed nuclear facility. This has important implications for the traceability, quality assurance and availability of safety critical diagnostics, and for the control of the design and procurement of all diagnostics. The high neutron flux/fluence also constrains the design of diagnostics, which must offer shielding consistent with the allowable dose rates on critical components of the Tokamak, and themselves be tolerant of the radiation level at the diagnostic. This paper presents an overview of the more critical issues for ITER diagnostics

  4. Intense ion beam diagnostics for light ion inertial fusion experiments on PBFA 2

    International Nuclear Information System (INIS)

    Leeper, R.J.; Stygar, W.A.; Bailey, J.E.; Baldwin, G.T.; Bloomquist, D.D.; Carlson, A.L.; Chandler, G.; Crist, C.E.; Cooper, G.; Derszon, M.S.; Dukart, R.J.; Fehl, D.L.; Hebron, D.E.; Johnson, D.J.; Kensek, R.P.; Landron, C.O.; Lee, J.R.; Lockner, T.R.; Mattson, C.R.; Matzen, M.K.; Maenchen, J.; Mehlhorn, T.A.; Mix, L.P.; Muron, D.J.; Nash, T.; Nelson, W.E.; Reyes, P.; Rockett, P.; Ruiz, C.L.; Schmidlapp, A.; Stinnett, R.W.; Sujka, B.; Wenger, D.F.

    1991-01-01

    A review of recent developments in intense ion beam diagnostics used in the light ion inertial confinement fusion (ICF) program on the PBFA-2 accelerator at Sandia National Laboratories will be presented. These developments have occurred in each of several generic classes of diagnostics, namely, imaging diagnostics, particle spectrograph diagnostics, nuclear activation, and visible spectroscopy. Critical beam parameters measured by the diagnostic include spatial profile, absolute number, species, anode plasma temperature and density, beam divergence, and beam voltage current density, and power density. A unique feature of these diagnostics is that they are capable of operating in hard (multi-Mev) X-ray (bremsstrahlung) backgrounds of some 10 10 - 10 12 rad/s. The operating principles of each diagnostic will be summarized in the paper, with examples of how the diagnostics may be integrated together to form a complete diagnostic system. The paper will close with a discussion of several near diagnostic systems that are presently being developed. 13 refs., 6 figs

  5. Diagnostic radionuclide imaging of amyloid: biological targeting by circulating human serum amyloid P component

    Energy Technology Data Exchange (ETDEWEB)

    Hawkins, P.N.; Lavender, J.P.; Myers, M.J.; Pepys, M.B.

    1988-06-25

    The specific molecular affinity of the normal plasma protein, serum amyloid P component (SAP), for all known types of amyloid fibrils was used to develop a new general diagnostic method for in-vivo radionuclide imaging of amyloid deposits. After intravenous injection of /sup 123/I-labelled purified human SAP there was specific uptake into amyloid deposits in all affected patients, 7 with systematic AL amyloid, 5 with AA amyloid, and 2 with ..beta../sub 2/M amyloid, in contrast to the complete absence of any tissue localisation in 5 control subjects. Distinctive high-resolution scintigraphic images, even of minor deposits in the carpal regions, bone marrow, or adrenals, were obtained. This procedure should yield much information on the natural history and the management of amyloidosis, the presence of which has hitherto been confirmed only by biopsy. Clearance and metabolic studies indicated that, in the presence of extensive amyloidosis, the rate of synthesis of SAP was greatly increased despite maintenance of normal plasma levels. Futhermore, once localised to amyloid deposits the /sup 123/I-SAP persisted for long periods and was apparently protected from its normal rapid degradation. These findings shed new light on the pathophysiology of amyloid and may have implications for therapeutic strategies based upon specific molecular targeting with SAP.

  6. Robotic vehicle uses acoustic sensors for voice detection and diagnostics

    Science.gov (United States)

    Young, Stuart H.; Scanlon, Michael V.

    2000-07-01

    An acoustic sensor array that cues an imaging system on a small tele- operated robotic vehicle was used to detect human voice and activity inside a building. The advantage of acoustic sensors is that it is a non-line of sight (NLOS) sensing technology that can augment traditional LOS sensors such as visible and IR cameras. Acoustic energy emitted from a target, such as from a person, weapon, or radio, will travel through walls and smoke, around corners, and down corridors, whereas these obstructions would cripple an imaging detection system. The hardware developed and tested used an array of eight microphones to detect the loudest direction and automatically setter a camera's pan/tilt toward the noise centroid. This type of system has applicability for counter sniper applications, building clearing, and search/rescue. Data presented will be time-frequency representations showing voice detected within rooms and down hallways at various ranges. Another benefit of acoustics is that it provides the tele-operator some situational awareness clues via low-bandwidth transmission of raw audio data for the operator to interpret with either headphones or through time-frequency analysis. This data can be useful to recognize familiar sounds that might indicate the presence of personnel, such as talking, equipment, movement noise, etc. The same array also detects the sounds of the robot it is mounted on, and can be useful for engine diagnostics and trouble shooting, or for self-noise emanations for stealthy travel. Data presented will characterize vehicle self noise over various surfaces such as tiles, carpets, pavement, sidewalk, and grass. Vehicle diagnostic sounds will indicate a slipping clutch and repeated unexpected application of emergency braking mechanism.

  7. Receiver operating characteristic (ROC) curves and the definition of threshold levels to diagnose coronary artery disease on electrocardiographic stress testing. Part I: The use of ROC curves in diagnostic medicine and electrocardiographic markers of ischaemia.

    Science.gov (United States)

    Barnabei, Luca; Marazìa, Stefania; De Caterina, Raffaele

    2007-11-01

    A common problem in diagnostic medicine, when performing a diagnostic test, is to obtain an accurate discrimination between 'normal' cases and cases with disease, owing to the overlapping distributions of these populations. In clinical practice, it is exceedingly rare that a chosen cut point will achieve perfect discrimination between normal cases and those with disease, and one has to select the best compromise between sensitivity and specificity by comparing the diagnostic performance of different tests or diagnostic criteria available. Receiver operating characteristic (or receiver operator characteristic, ROC) curves allow systematic and intuitively appealing descriptions of the diagnostic performance of a test and a comparison of the performance of different tests or diagnostic criteria. This review will analyse the basic principles underlying ROC curves and their specific application to the choice of optimal parameters on exercise electrocardiographic (ECG) stress testing. Part I will focus on theoretical description and analysis along with reviewing the common problems related to the diagnosis of myocardial ischaemia by means of exercise ECG stress testing. Part II will be devoted to applying ROC curves to available diagnostic criteria through the analysis of ECG stress test parameters.

  8. Fast infectious diseases diagnostics based on microfluidic biochip system

    Directory of Open Access Journals (Sweden)

    Qin Huang

    2017-03-01

    Full Text Available Molecular diagnostics is one of the most important tools currently in use for clinical pathogen detection due to its high sensitivity, specificity, and low consume of sample and reagent is keyword to low cost molecular diagnostics. In this paper, a sensitive DNA isothermal amplification method for fast clinical infectious diseases diagnostics at aM concentrations of DNA was developed using a polycarbonate (PC microfluidic chip. A portable confocal optical fluorescence detector was specifically developed for the microfluidic chip that was capable of highly sensitive real-time detection of amplified products for sequence-specific molecular identification near the optical diffraction limit with low background. The molecular diagnostics of Listeria monocytogenes with nucleic acid extracted from stool samples was performed at a minimum DNA template concentration of 3.65aM, and a detection limit of less than five copies of genomic DNA. Contrast to the general polymerase chain reaction (PCR at eppendorf (EP tube, the detection time in our developed method was reduced from 1.5h to 45min for multi-target parallel detection, the consume of sample and reagent was dropped from 25μL to 1.45μL. This novel microfluidic chip system and method can be used to develop a micro total analysis system as a clinically relevant pathogen molecular diagnostics method via the amplification of targets, with potential applications in biotechnology, medicine, and clinical molecular diagnostics.

  9. Operational Benefits of Meeting California's Energy Storage Targets

    Energy Technology Data Exchange (ETDEWEB)

    Eichman, Josh [National Renewable Energy Lab. (NREL), Golden, CO (United States); Denholm, Paul [National Renewable Energy Lab. (NREL), Golden, CO (United States); Jorgenson, Jennie [National Renewable Energy Lab. (NREL), Golden, CO (United States); Helman, Udi [Helman Analytics, San Francisco, CA (United States)

    2015-12-18

    In October 2013, the California Public Utilities Commission (CPUC) finalized procurement targets and other requirements to its jurisdictional utilities for a minimum of 1,325 MW of 'viable and cost-effective' energy storage systems by 2020. The goal of this study is to explore several aspects of grid operations in California and the Western Interconnection resulting from meeting the CPUC storage targets. We perform this analysis using a set of databases and grid simulation tools developed and implemented by the CPUC, the California Independent System Operator (CAISO), and the California Energy Commission (CEC) for the CPUC's Long-term Procurement Plan (LTPP). The 2014 version of this database contains information about generators, storage, transmission, and electrical demand, for California in the year 2024 for both 33% and 40% renewable energy portfolios. We examine the value of various services provided by energy storage in these scenarios. Sensitivities were performed relating to the services energy storage can provide, the capacity and duration of storage devices, export limitations, and negative price floor variations. Results show that a storage portfolio, as outlined by the CPUC, can reduce curtailment and system-wide production costs for 33% and 40% renewable scenarios. A storage device that can participate in energy and ancillary service markets provides the grid with the greatest benefit; the mandated storage requirement of 1,325 MW was estimated to reduce the total cost of production by about 78 million per year in the 33% scenario and 144 million per year in the 40% scenario. Much of this value is derived from the avoided start and stop costs of thermal generators and provision of ancillary services. A device on the 2024 California grid and participating in only ancillary service markets can provide the system with over 90% of the value as the energy and ancillary service device. The analysis points to the challenge of new storage

  10. 21 CFR 886.1880 - Fusion and stereoscopic target.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fusion and stereoscopic target. 886.1880 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1880 Fusion and stereoscopic target. (a) Identification. A fusion and stereoscopic target is a device intended for use as a viewing object...

  11. Advanced diagnostic graphics

    International Nuclear Information System (INIS)

    Bray, M.A.; Petersen, R.J.; Clark, M.T.; Gertman, D.I.

    1981-01-01

    This paper reports US NRC-sponsored research at the Idaho National Engineering Laboratory (INEL) involving evaluation of computer-based diagnostic graphics. The specific targets of current evaluations are multivariate data display formats which may be used in Safety Parameter Display Systems (SPDS) being developed for nuclear power plant control rooms. The purpose of the work is to provide a basis for NRC action in regulating licensee SPDSs or later computer/cathode ray tube (CRT) applications in nuclear control rooms

  12. Plasmon-Based Colorimetric Nanosensors for Ultrasensitive Molecular Diagnostics.

    Science.gov (United States)

    Tang, Longhua; Li, Jinghong

    2017-07-28

    Colorimetric detection of target analytes with high specificity and sensitivity is of fundamental importance to clinical and personalized point-of-care diagnostics. Because of their extraordinary optical properties, plasmonic nanomaterials have been introduced into colorimetric sensing systems, which provide significantly improved sensitivity in various biosensing applications. Here we review the recent progress on these plasmonic nanoparticles-based colorimetric nanosensors for ultrasensitive molecular diagnostics. According to their different colorimetric signal generation mechanisms, these plasmonic nanosensors are classified into two categories: (1) interparticle distance-dependent colorimetric assay based on target-induced forming cross-linking assembly/aggregate of plasmonic nanoparticles; and (2) size/morphology-dependent colorimetric assay by target-controlled growth/etching of the plasmonic nanoparticles. The sensing fundamentals and cutting-edge applications will be provided for each of them, particularly focusing on signal generation and/or amplification mechanisms that realize ultrasensitive molecular detection. Finally, we also discuss the challenge and give our future perspective in this emerging field.

  13. Toward a new and noninvasive diagnostic method of papillary thyroid cancer by using peptide vectorized contrast agents targeted to galectin-1.

    Science.gov (United States)

    Fanfone, Deborah; Despretz, Nadège; Stanicki, Dimitri; Rubio-Magnieto, Jenifer; Fossépré, Mathieu; Surin, Mathieu; Rorive, Sandrine; Salmon, Isabelle; Vander Elst, Luce; Laurent, Sophie; Muller, Robert N; Saussez, Sven; Burtea, Carmen

    2017-10-06

    The incidence of papillary thyroid cancer has increased these last decades due to a better detection. High prevalence of nodules combined with the low incidence of thyroid cancers constitutes an important diagnostic challenge. We propose to develop an alternative diagnostic method to reduce the number of useless and painful thyroidectomies using a vectorized contrast agent for magnetic resonance imaging. Galectin-1 (gal-1), a protein overexpressed in well-differentiated thyroid cancer, has been targeted with a randomized linear 12-mer peptide library using the phage display technique. Selected peptides have been conjugated to ultrasmall superparamagnetic particles of iron oxide (USPIO). Peptides and their corresponding contrast agents have been tested in vitro for their specific binding and toxicity. Two peptides (P1 and P7) were selected according to their affinity toward gal-1. Their binding has been revealed by immunohistochemistry on human thyroid cancer biopsies, and they were co-localized with gal-1 by immunofluorescence on TPC-1 cell line. Both peptides induce a decrease in TPC-1 cells' adhesion to gal-1 immobilized on culture plates. After coupling to USPIO, the peptides preserved their affinity toward gal-1. Their specific binding has been corroborated by co-localization with gal-1 expressed by TPC-1 cells and by their ability to compete with anti-gal-1 antibody. The peptides and their USPIO derivatives produce no toxicity in HepaRG cells as determined by MTT assay. The vectorized contrast agents are potential imaging probes for thyroid cancer diagnosis. Moreover, the two gal-1-targeted peptides prevent cancer cell adhesion by interacting with the carbohydrate-recognition domain of gal-1.

  14. Symptom based diagnostic system using artificial neural networks

    International Nuclear Information System (INIS)

    Santosh; Vinod, Gopika; Saraf, R.K.

    2003-01-01

    Nuclear power plant experiences a number of transients during its operations. In case of such an undesired plant condition generally known as an initiating event, the operator has to carry out diagnostic and corrective actions. The operator's response may be too late to mitigate or minimize the negative consequences in such scenarios. The objective of this work is to develop an operator support system based on artificial neural networks that will assist the operator to identify the initiating events at the earliest stages of their developments. A symptom based diagnostic system has been developed to investigate the initiating events. Neutral networks are utilized for carrying out the event identification by continuously monitoring process parameters. Whenever an event is detected, the system will display the necessary operator actions along with the initiating event. The system will also show the graphical trend of process parameters that are relevant to the event. This paper describes the features of the software that is used to monitor the reactor. (author)

  15. Diagnostics for induction accelerators

    International Nuclear Information System (INIS)

    Fessenden, T.J.

    1996-04-01

    The induction accelerator was conceived by N. C. Christofilos and first realized as the Astron accelerator that operated at LLNL from the early 1960's to the end of 1975. This accelerator generated electron beams at energies near 6 MeV with typical currents of 600 Amperes in 400 ns pulses. The Advanced Test Accelerator (ATA) built at Livermore's Site 300 produced 10,000 Ampere beams with pulse widths of 70 ns at energies approaching 50 MeV. Several other electron and ion induction accelerators have been fabricated at LLNL and LBNL. This paper reviews the principal diagnostics developed through efforts by scientists at both laboratories for measuring the current, position, energy, and emittance of beams generated by these high current, short pulse accelerators. Many of these diagnostics are closely related to those developed for other accelerators. However, the very fast and intense current pulses often require special diagnostic techniques and considerations. The physics and design of the more unique diagnostics developed for electron induction accelerators are presented and discussed in detail

  16. Comparison with myocardial perfusion MRI and myocardial perfusion SPECT in the diagnostic performance of coronary artery disease. A meta-analysis

    International Nuclear Information System (INIS)

    Iwata, Kunihiro; Kubota, Makoto; Ogasawara, Katsuhiko

    2008-01-01

    We compared the diagnostic abilities of stress myocardial perfusion MRI (myocardial perfusion MRI) and myocardial perfusion single photon emission computed tomography (SPECT), using a meta-analysis method. We investigated the diagnostic abilities of MRI and SPECT in similar subject groups in reports written in English or Japanese. The reports to be used for analysis were selected according to a ''screening standard,'' which was established in advance. After consolidating the data from the selected reports, we compared the integrated odds ratio, the point estimation values of sensibility/specificity, and the summary receiver operating characteristic (ROC) curve. For the analysis, six reports were selected (subjects: 153, coronary-artery target sites: 447). Meta-analysis revealed that the diagnostic ability of myocardial perfusion MRI was superior to that of myocardial perfusion SPECT regarding each of the parameters. This is considered to be supportive evidence of the usefulness of myocardial perfusion MRI. (author)

  17. Recent developments of ECE diagnostics at JET

    Energy Technology Data Exchange (ETDEWEB)

    Luna, E. de la; Sanchez, J. [Association Euratom-Ciemat para Fusion, Ciemant (Spain); Cientoli, C.; Blanchard, P.; Joffrin, E.; Mazon, D. [Association Euratom-ENEA sulla Fusione, IFP-CNR, Milano (Italy); Riva, M.; Zerbini, M. [Association Euratom-ENEA sulla Fusione Centro Ricerche Energia Frascati (Italy); Conway, G. [IPP-Euratom Association, Garching (Germany); Felton, R.; Fessey, J.; Gowers, C. [Euratom/UKAEA Fusion Association, Culham Science Centre, Abingdon (United Kingdom); Murari, A. [Consorzio RFX, Association Euratom-ENEA sulla Fusione, Padova (Italy)

    2004-07-01

    In JET, two types of ECE (electron cyclotron emission) instruments are routinely operated to provide electron temperature measurements: a Michelson interferometer and a heterodyne radiometer. ECE diagnostics are able to provide time-resolved electron temperature profiles with high spatial and temporal resolution, and have proven to play a fundamental role in the investigation and development of internal transport barriers (ITBs) in JET. In this paper we report on the major upgrade of the ECE diagnostics systems currently in progress at JET. Diagnostic developments include an upgrade of the multi-channel heterodyne radiometer, aimed at extending the radial region over which T{sub e} measurement can be performed, and the installation of a new Michelson interferometer with fast scanning capability, to improve the frequency and temporal resolution of the multi-harmonic ECE measurements at JET. Moreover, a future extension of the ECE system, an oblique ECE diagnostic to measure the ECE spectra at different angles with respect to the normal to the magnetic field, is being developed. This diagnostic is expected to give valuable insight into the interpretation of ECE measurements in high T{sub e}-plasmas and should be available for measurements once JET resumes operation in 2005.In this paper, the recent developments in the JET ECE diagnostic system will be described and illustrated with some recent results, with an emphasis on issues related with calibration stability, high-Te plasmas and ITB studies. Some of these issues will be discussed in the context of ITER.

  18. Cable Diagnostic Focused Initiative

    Energy Technology Data Exchange (ETDEWEB)

    Hartlein, R.A.; Hampton, R.N.

    2010-12-30

    This report summarizes an extensive effort made to understand how to effectively use the various diagnostic technologies to establish the condition of medium voltage underground cable circuits. These circuits make up an extensive portion of the electric delivery infrastructure in the United States. Much of this infrastructure is old and experiencing unacceptable failure rates. By deploying efficient diagnostic testing programs, electric utilities can replace or repair circuits that are about to fail, providing an optimal approach to improving electric system reliability. This is an intrinsically complex topic. Underground cable systems are not homogeneous. Cable circuits often contain multiple branches with different cable designs and a range of insulation materials. In addition, each insulation material ages differently as a function of time, temperature and operating environment. To complicate matters further, there are a wide variety of diagnostic technologies available for assessing the condition of cable circuits with a diversity of claims about the effectiveness of each approach. As a result, the benefits of deploying cable diagnostic testing programs have been difficult to establish, leading many utilities to avoid the their use altogether. This project was designed to help address these issues. The information provided is the result of a collaborative effort between Georgia Tech NEETRAC staff, Georgia Tech academic faculty, electric utility industry participants, as well as cable system diagnostic testing service providers and test equipment providers. Report topics include: •How cable systems age and fail, •The various technologies available for detecting potential failure sites, •The advantages and disadvantages of different diagnostic technologies, •Different approaches for utilities to employ cable system diagnostics. The primary deliverables of this project are this report, a Cable Diagnostic Handbook (a subset of this report) and an online

  19. A Self-Diagnostic System for the M6 Accelerometer

    Science.gov (United States)

    Flanagan, Patrick M.; Lekki, John

    2001-01-01

    The design of a Self-Diagnostic (SD) accelerometer system for the Space Shuttle Main Engine is presented. This retrofit system connects diagnostic electronic hardware and software to the current M6 accelerometer system. This paper discusses the general operation of the M6 accelerometer SD system and procedures for developing and evaluating the SD system. Signal processing techniques using M6 accelerometer diagnostic data are explained. Test results include diagnostic data responding to changing ambient temperature, mounting torque and base mounting impedance.

  20. A near infra-red video system as a protective diagnostic for electron cyclotron resonance heating operation in the Wendelstein 7-X stellarator

    Energy Technology Data Exchange (ETDEWEB)

    Preynas, M.; Laqua, H. P.; Marsen, S.; Reintrog, A. [Max-Planck-Institut für Plasmaphysik (IPP), D-17491 Greifswald (Germany); Corre, Y.; Moncada, V.; Travere, J.-M. [IRFM, CEA-Cadarache, 13108 Saint Paul lez Durance Cedex (France)

    2015-11-15

    The Wendelstein 7-X stellarator is a large nuclear fusion device based at Max-Planck-Institut für Plasmaphysik in Greifswald in Germany. The main plasma heating system for steady state operation in W7-X is electron cyclotron resonance heating (ECRH). During operation, part of plama facing components will be directly heated by the non-absorbed power of 1 MW rf beams of ECRH. In order to avoid damages of such components made of graphite tiles during the first operational phase, a near infra-red video system has been developed as a protective diagnostic for safe and secure ECRH operation. Both the mechanical design housing the camera and the optical system are very flexible and respect the requirements of steady state operation. The full system including data acquisition and control system has been successfully tested in the vacuum vessel, including on-line visualization and data storage of the four cameras equipping the ECRH equatorial launchers of W7-X.

  1. Use of diagnostic dynamic contrast-enhanced (DCE)-MRI for targeting of soft tissue tumour biopsies at 3T: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Noebauer-Huhmann, Iris-Melanie [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Neuroradiology and Musculoskeletal Radiology, Vienna (Austria); Medical University of Vienna, High Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Medical University of Vienna/Vienna General Hospital, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Amann, Gabriele [Medical University of Vienna, Clinical Institute for Pathology, Vienna (Austria); Krssak, Martin [Medical University of Vienna, High Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Medical University of Vienna, Department of Internal Medicine III, Endocrinology and Metabolism, Vienna (Austria); Panotopoulos, Joannis; Funovics, Philipp; Windhager, Reinhard [Medical University of Vienna, Department of Orthopaedics, Vienna (Austria); Szomolanyi, Pavol [Medical University of Vienna, High Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Slovak Academy of Sciences, Department of Imaging Methods, Institute of Measurement Science, Bratislava (Slovakia); Weber, Michael; Czerny, Christian; Nemec, Stefan [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Neuroradiology and Musculoskeletal Radiology, Vienna (Austria); Breitenseher, Martin [Landesklinikum Waldviertel Horn, Horn (Austria); Grabner, Guenther; Bogner, Wolfgang [Medical University of Vienna, High Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Dominkus, Martin [Orthopaedics Hospital Speising, Vienna (Austria); Trattnig, Siegfried [Medical University of Vienna, High Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Ludwig Boltzmann Institute for Experimental and Clinical Traumatology, Austrian Cluster for Tissue Regeneration, Vienna (Austria)

    2015-07-15

    To test the feasibility and accuracy of MR-guided soft tissue tumour biopsy at 3T, using the dynamic contrast-enhanced (DCE) information from staging MRI for intralesional targeting. After obtaining written informed consent for this institutional review board-approved study, 53 patients with suspected soft tissue tumours prospectively underwent preoperative staging MRI at 3T, including DCE, and subsequent MR-guided core needle biopsy. In 44/53 cases, DCE was heterogeneous and was used for intralesional biopsy targeting. Surgical, whole-specimen histology was used as the gold standard in 43/44 patients and revealed 42 soft tissue tumours (24 men; 18 women; mean age, 52 years; range, 19 - 84). Final surgical histology revealed eight benign lesions, six tumours of intermediate dignity, and 28 malignancies. All malignancies had shown heterogeneous DCE. The diagnostic yield of the biopsies was 100 % (42/42). Histological accuracy rates of biopsy were 100 % in predicting the dignity (42/42; 95 % CI [0.916 - 1.000]), 95.2 % for the tissue-specific entity (40/42; 95 % CI [0.847 - 0.987]), and 90.5 % for the tumour grade (38/42; 95 % CI [0.779 - 0.962]). Our preliminary study indicates that biopsy of soft tissue tumours can be performed accurately and safely with DCE targeted MR-guidance at 3T, using a combined staging/biopsy MRI protocol. (orig.)

  2. Use of diagnostic dynamic contrast-enhanced (DCE)-MRI for targeting of soft tissue tumour biopsies at 3T: preliminary results

    International Nuclear Information System (INIS)

    Noebauer-Huhmann, Iris-Melanie; Amann, Gabriele; Krssak, Martin; Panotopoulos, Joannis; Funovics, Philipp; Windhager, Reinhard; Szomolanyi, Pavol; Weber, Michael; Czerny, Christian; Nemec, Stefan; Breitenseher, Martin; Grabner, Guenther; Bogner, Wolfgang; Dominkus, Martin; Trattnig, Siegfried

    2015-01-01

    To test the feasibility and accuracy of MR-guided soft tissue tumour biopsy at 3T, using the dynamic contrast-enhanced (DCE) information from staging MRI for intralesional targeting. After obtaining written informed consent for this institutional review board-approved study, 53 patients with suspected soft tissue tumours prospectively underwent preoperative staging MRI at 3T, including DCE, and subsequent MR-guided core needle biopsy. In 44/53 cases, DCE was heterogeneous and was used for intralesional biopsy targeting. Surgical, whole-specimen histology was used as the gold standard in 43/44 patients and revealed 42 soft tissue tumours (24 men; 18 women; mean age, 52 years; range, 19 - 84). Final surgical histology revealed eight benign lesions, six tumours of intermediate dignity, and 28 malignancies. All malignancies had shown heterogeneous DCE. The diagnostic yield of the biopsies was 100 % (42/42). Histological accuracy rates of biopsy were 100 % in predicting the dignity (42/42; 95 % CI [0.916 - 1.000]), 95.2 % for the tissue-specific entity (40/42; 95 % CI [0.847 - 0.987]), and 90.5 % for the tumour grade (38/42; 95 % CI [0.779 - 0.962]). Our preliminary study indicates that biopsy of soft tissue tumours can be performed accurately and safely with DCE targeted MR-guidance at 3T, using a combined staging/biopsy MRI protocol. (orig.)

  3. Aircraft gas turbine engine vibration diagnostics

    OpenAIRE

    Stanislav Fábry; Marek Češkovič

    2017-01-01

    In the Czech and Slovak aviation are in service elderly aircrafts, usually produced in former Soviet Union. Their power units can be operated in more efficient way, in case of using additional diagnostic methods that allow evaluating their health. Vibration diagnostics is one of the methods indicating changes of rotational machine dynamics. Ground tests of aircraft gas turbine engines allow vibration recording and analysis. Results contribute to airworthiness evaluation and making corrections...

  4. Evaluating Diagnostic Point-of-Care Tests in Resource-Limited Settings

    Science.gov (United States)

    Drain, Paul K; Hyle, Emily P; Noubary, Farzad; Freedberg, Kenneth A; Wilson, Douglas; Bishai, William; Rodriguez, William; Bassett, Ingrid V

    2014-01-01

    Diagnostic point-of-care (POC) testing is intended to minimize the time to obtain a test result, thereby allowing clinicians and patients to make an expeditious clinical decision. As POC tests expand into resource-limited settings (RLS), the benefits must outweigh the costs. To optimize POC testing in RLS, diagnostic POC tests need rigorous evaluations focused on relevant clinical outcomes and operational costs, which differ from evaluations of conventional diagnostic tests. Here, we reviewed published studies on POC testing in RLS, and found no clearly defined metric for the clinical utility of POC testing. Therefore, we propose a framework for evaluating POC tests, and suggest and define the term “test efficacy” to describe a diagnostic test’s capacity to support a clinical decision within its operational context. We also proposed revised criteria for an ideal diagnostic POC test in resource-limited settings. Through systematic evaluations, comparisons between centralized diagnostic testing and novel POC technologies can be more formalized, and health officials can better determine which POC technologies represent valuable additions to their clinical programs. PMID:24332389

  5. Targets of operation monitoring

    International Nuclear Information System (INIS)

    Wenger, H.

    1997-01-01

    The condition monitoring system of a nuclear power plant should be an assurance for the user and the authorities that the safety of the installation constantly corresponds to the nominal condition. As soon as deviations from these conditions occur, it should quickly provide fundamentals for corrective measures. It contributes to a high degree of availability of the installation and makes safe and economical operation throughout the whole life of the installation possible. (author) 1 fig

  6. Enhanced NIF neutron activation diagnostics.

    Science.gov (United States)

    Yeamans, C B; Bleuel, D L; Bernstein, L A

    2012-10-01

    The NIF neutron activation diagnostic suite relies on removable activation samples, leading to operational inefficiencies and a fundamental lower limit on the half-life of the activated product that can be observed. A neutron diagnostic system measuring activation of permanently installed samples could remove these limitations and significantly enhance overall neutron diagnostic capabilities. The physics and engineering aspects of two proposed systems are considered: one measuring the (89)Zr/(89 m)Zr isomer ratio in the existing Zr activation medium and the other using potassium zirconate as the activation medium. Both proposed systems could improve the signal-to-noise ratio of the current system by at least a factor of 5 and would allow independent measurement of fusion core velocity and fuel areal density.

  7. Shiva target irradiation facility

    International Nuclear Information System (INIS)

    Manes, K.R.; Ahlstrom, H.G.; Coleman, L.W.; Storm, E.K.; Glaze, J.A.; Hurley, C.A.; Rienecker, F.; O'Neal, W.C.

    1977-01-01

    The first laser/plasma studies performed with the Shiva laser system will be two sided irradiations extending the data obtained by other LLL lasers to higher powers. The twenty approximately 1 TW laser pulses will reach the target simultaneously from above and below in nested pentagonal clusters. The upper and lower clusters of ten beams each are radially polarized so that they strike the target in p-polarization and maximize absorption. This geometry introduces laser system isolation problems which will be briefly discussed. The layout and types of target diagnostics will be described and a brief status report on the facility given

  8. Diagnostic performance of a novel loop-mediated isothermal amplification (LAMP) assay targeting the apicoplast genome for malaria diagnosis in a field setting in sub-Saharan Africa.

    Science.gov (United States)

    Oriero, Eniyou C; Okebe, Joseph; Jacobs, Jan; Van Geertruyden, Jean-Pierre; Nwakanma, Davis; D'Alessandro, Umberto

    2015-10-09

    New diagnostic tools to detect reliably and rapidly asymptomatic and low-density malaria infections are needed as their treatment could interrupt transmission. Isothermal amplification techniques are being explored for field diagnosis of malaria. In this study, a novel molecular tool (loop-mediated isothermal amplification-LAMP) targeting the apicoplast genome of Plasmodium falciparum was evaluated for the detection of asymptomatic malaria-infected individuals in a rural setting in The Gambia. A blood was collected from 341 subjects (median age 9 years, range 1-68 years) screened for malaria. On site, a rapid diagnostic test (RDT, SD Bioline Malaria Antigen P.f) was performed, thick blood films (TBF) slides for microscopy were prepared and dry blood spots (DBS) were collected on Whatman(®) 903 Specimen collection paper. The TBF and DBS were transported to the field laboratory where microscopy and LAMP testing were performed. The latter was done on DNA extracted from the DBS using a crude (methanol/heating) extraction method. A laboratory-based PCR amplification was done on all the samples using DNA extracted with the Qiagen kit and its results were taken as reference for all the other tests. Plasmodium falciparum malaria prevalence was 37 % (127/341) as detected by LAMP, 30 % (104/341) by microscopy and 37 % (126/341) by RDT. Compared to the reference PCR method, sensitivity was 92 % for LAMP, 78 % for microscopy, and 76 % for RDT; specificity was 97 % for LAMP, 99 % for microscopy, and 88 % for RDT. Area under the receiver operating characteristic (ROC) curve in comparison with the reference standard was 0.94 for LAMP, 0.88 for microscopy and 0.81 for RDT. Turn-around time for the entire LAMP assay was approximately 3 h and 30 min for an average of 27 ± 9.5 samples collected per day, compared to a minimum of 10 samples an hour per operator by RDT and over 8 h by microscopy. The LAMP assay could produce reliable results the same day of the screening. It could

  9. SNS Diagnostics Timing Integration

    CERN Document Server

    Long, Cary D; Murphy, Darryl J; Pogge, James; Purcell, John D; Sundaram, Madhan

    2005-01-01

    The Spallation Neutron Source (SNS) accelerator systems will deliver a 1.0 GeV, 1.4 MW proton beam to a liquid mercury target for neutron scattering research. The accelerator complex consists of a 1 GeV linear accelerator, an accumulator ring and associated transport lines. The SNS diagnostics platform is PC-based running Windows XP Embedded for its OS and LabVIEW as its programming language. Coordinating timing among the various diagnostics instruments with the generation of the beam pulse is a challenging task that we have chosen to divide into three phases. First, timing was derived from VME based systems. In the second phase, described in this paper, timing pulses are generated by an in house designed PCI timing card installed in ten diagnostics PCs. Using fan-out modules, enough triggers were generated for all instruments. This paper describes how the Timing NAD (Network Attached Device) was rapidly developed using our NAD template, LabVIEW's PCI driver wizard, and LabVIEW Channel Access library. The NAD...

  10. Molecular diagnostics of periodontitis.

    Science.gov (United States)

    Korona-Głowniak, Izabela; Siwiec, Radosław; Berger, Marcin; Malm, Anna; Szymańska, Jolanta

    2017-01-28

    The microorganisms that form dental plaque are the main cause of periodontitis. Their identification and the understanding of the complex relationships and interactions that involve these microorganisms, environmental factors and the host's health status enable improvement in diagnostics and targeted therapy in patients with periodontitis. To this end, molecular diagnostics techniques (both techniques based on the polymerase chain reaction and those involving nucleic acid analysis via hybridization) come increasingly into use. On the basis of a literature review, the following methods are presented: polymerase chain reaction (PCR), real-time polymerase chain reaction (real-time PCR), 16S rRNA-encoding gene sequencing, checkerboard and reverse-capture checkerboard hybridization, microarrays, denaturing gradient gel electrophoresis (DGGE), temperature gradient gel electrophoresis (TGGE), as well as terminal restriction fragment length polymorphism (TRFLP) and next generation sequencing (NGS). The advantages and drawbacks of each method in the examination of periopathogens are indicated. The techniques listed above allow fast detection of even small quantities of pathogen present in diagnostic material and prove particularly useful to detect microorganisms that are difficult or impossible to grow in a laboratory.

  11. Studies on WWER core diagnostics

    International Nuclear Information System (INIS)

    Lunin, G.L.; Mitin, V.I.; Bulavin, V.V.

    1987-01-01

    The reliability and safety of nuclear power plants have decisive meaning under the situation that nuclear power generation steadily increases, and among various measures aiming at ensuring the reliability and safety in the operation of nuclear power plants, the countermeasures for protecting reactor core, main process equipment and high pressure circuits from damage have the important role, and the monitoring of condition and the organization of forecast, which are carried out continuously or periodically during the operation of nuclear power stations using the diagnostic expert system specially developed for the purpose, are included in them. Such monitoring enables the early detection of mechanical damage, increase of vibration, defects caused during operation and so on in reactor cores and primary and secondary circuits, and the continuous watching of defect developments. Also boiling in a core is detected, the place of abnormality occurrence is identified, and the intensity and characteristics of boiling are determined, thus the occurrence of dangerous condition is prevented. The developments of an in-core monitoring system and noise diagnostic systems are reported. (Kako, I.)

  12. A PC-PCL-based control system for the high-voltage pulsed-power operation of the Intense Diagnostic Neutral Beam (IDNB) Experiment

    International Nuclear Information System (INIS)

    Gribble, R.

    1993-06-01

    A stand-alone, semiautomated control system for the high-voltage pulsed-power energy sources on the Intense Diagnostic Neutral Beam Experiment at Los Alamos National Laboratory using personal computer (PC) and programmable logic controller (PLC) technology has been developed and implemented. The control system, consisting of a PC with the graphic operator interface, the network connecting the PC to the PLC, the PLC, the PLC I/O modules, fiber-optic interfaces and software, is described

  13. Combining a thermal-imaging diagnostic with an existing imaging VISAR diagnostic at the National Ignition Facility (NIF)

    International Nuclear Information System (INIS)

    Robert M, Malone; John R, Celesteb; Peter M, Celliers; Brent C, Froggeta; Robert L, Guyton; Morris I, Kaufman; Tony L, Lee; Brian J, MacGowan; Edmund W, Ng; Imants P, Reinbachs; Ronald B, Robinson; Lynn G, Seppala; Tom W, Tunnell; Phillip W, Watts

    2005-01-01

    Optical diagnostics are currently being designed to analyze high-energy density physics experiments at the National Ignition Facility (NIF). Two independent line-imaging Velocity Interferometer System for Any Reflector (VISAR) interferometers have been fielded to measure shock velocities, breakout times, and emission of targets having sizes of 1-5 mm. An 8-inch-diameter, fused silica triplet lens collects light at f/3 inside the 30-foot-diameter NIF vacuum chamber. VISAR recordings use a 659.5-nm probe laser. By adding a specially coated beam splitter to the interferometer table, light at wavelengths from 540 to 645 nm is spilt into a thermal-imaging diagnostic. Because fused silica lenses are used in the first triplet relay, the intermediate image planes for different wavelengths separate by considerable distances. A corrector lens on the interferometer table reunites these separated wavelength planes to provide a good image. Thermal imaging collects light at f/5 from a 2-mm object placed at Target Chamber Center (TCC). Streak cameras perform VISAR and thermal-imaging recording. All optical lenses are on kinematic mounts so that pointing accuracy of the optical axis may be checked. Counter-propagating laser beams (orange and red) are used to align both diagnostics. The red alignment laser is selected to be at the 50 percent reflection point of the beam splitter. This alignment laser is introduced at the recording streak cameras for both diagnostics and passes through this special beam splitter on its way into the NIF vacuum chamber

  14. Fielding of the on-axis diagnostic package at Z

    International Nuclear Information System (INIS)

    Hurst, M.J.; Nash, T.J.; Derzon, M.; Kellogg, J.W.; Torres, J.; McGurn, J.; Seaman, J.; Jobe, D.; Lazier, S.E.

    1998-06-01

    The authors have developed a comprehensive diagnostic package for observing z-pinch radiation along the pinch axis on the Z accelerator. The instrumentation, which was fielded on the axial package, are x-ray diagnostics requiring direct lines of sight to the target. The diagnostics require vacuum access to the center of the accelerator. The environment is a hostile one, where one must deal with an intense, energetic photon flux (>100 keV), EMP, debris (e.g. bullets or shrapnel), and mechanical shock in order for the diagnostics to survive. In addition, practical constraints require the package be refurbished and utilized on a once a day shot schedule. In spite of this harsh environment, the authors have successfully fielded the diagnostic package with a high survivability of the data and the instruments. In this paper, they describe the environment and issues related to the re-entrant diagnostic package's implementation and maintenance

  15. Optomechanical considerations for the VISAR diagnostic at the National Ignition Facility (NIF)

    International Nuclear Information System (INIS)

    Morris I. Kaufman, John R. Celeste, Brent C. Frogget, Tony L. Lee, Brian J. GacGowan, Robert M. Malone, Edmund W. Ng, Tom W. Tunnell, Phillip W. Watts

    2006-01-01

    The National Ignition Facility (NIF) requires optical diagnostics for measuring shock velocities in shock physics experiments. The velocity interferometer for any reflector measures shock velocities at a location remote to the NIF target chamber. Our team designed two systems, one for a polar port orientation, and the other to accommodate two equatorial ports. The polar-oriented design requires a 48-m optical relay to move the light from inside the target chamber to a separately housed measurement and laser illumination station. The currently operational equatorial design requires a much shorter relay of 21 m. Both designs posed significant optomechanical challenges due to the long optical path length, large quantity of optical elements, and stringent NIF requirements. System design had to tightly control the use of lubricants and materials, especially those inside the vacuum chamber; tolerate earthquakes and radiation; and consider numerous other tolerance, alignment, and steering adjustment issues. To ensure compliance with NIF performance requirements, we conducted a finite element analysis

  16. Chasing down the triple-negative myeloproliferative neoplasms: Implications for molecular diagnostics.

    Science.gov (United States)

    Langabeer, Stephen E

    2016-01-01

    The majority of patients with classical myeloproliferative neoplasms (MPN) of polycythemia vera, essential thrombocythemia, and primary myelofibrosis harbor distinct disease-driving mutations within the JAK2 , CALR , or MPL genes. The term triple-negative has been recently applied to those MPN without evidence of these consistent mutations, prompting whole or targeted exome sequencing approaches to determine the driver mutational status of this subgroup. These strategies have identified numerous novel mutations that occur in alternative exons of both JAK2 and MPL , the majority of which result in functional activation. Current molecular diagnostic approaches may possess insufficient coverage to detect these alternative mutations, prompting further consideration of targeted exon sequencing into routine diagnostic practice. How to incorporate these illuminating findings into the expanding molecular diagnostic algorithm for MPN requires continual attention.

  17. An expression meta-analysis of predicted microRNA targets identifies a diagnostic signature for lung cancer

    Directory of Open Access Journals (Sweden)

    Liang Yu

    2008-12-01

    Full Text Available Abstract Background Patients diagnosed with lung adenocarcinoma (AD and squamous cell carcinoma (SCC, two major histologic subtypes of lung cancer, currently receive similar standard treatments, but resistance to adjuvant chemotherapy is prevalent. Identification of differentially expressed genes marking AD and SCC may prove to be of diagnostic value and help unravel molecular basis of their histogenesis and biologies, and deliver more effective and specific systemic therapy. Methods MiRNA target genes were predicted by union of miRanda, TargetScan, and PicTar, followed by screening for matched gene symbols in NCBI human sequences and Gene Ontology (GO terms using the PANTHER database that was also used for analyzing the significance of biological processes and pathways within each ontology term. Microarray data were extracted from Gene Expression Omnibus repository, and tumor subtype prediction by gene expression used Prediction Analysis of Microarrays. Results Computationally predicted target genes of three microRNAs, miR-34b/34c/449, that were detected in human lung, testis, and fallopian tubes but not in other normal tissues, were filtered by representation of GO terms and their ability to classify lung cancer subtypes, followed by a meta-analysis of microarray data to classify AD and SCC. Expression of a minimal set of 17 predicted miR-34b/34c/449 target genes derived from the developmental process GO category was identified from a training set to classify 41 AD and 17 SCC, and correctly predicted in average 87% of 354 AD and 82% of 282 SCC specimens from total 9 independent published datasets. The accuracy of prediction still remains comparable when classifying 103 AD and 79 SCC samples from another 4 published datasets that have only 14 to 16 of the 17 genes available for prediction (84% and 85% for AD and SCC, respectively. Expression of this signature in two published datasets of epithelial cells obtained at bronchoscopy from cigarette

  18. Review of operational aids for nuclear plant operators

    International Nuclear Information System (INIS)

    Kisner, R.A.

    1983-01-01

    Many approaches are being explored to improve the safety of nuclear plant operations. One approach is to supply high-quality, relevant information by means of computer-based diagnostic systems to assist plant operators in performing their operational and safety-related roles. The evaluation of operational aids to ensure safe plant operations is a necessary function of NRC. This work has two purposes: to collect limited data on a diversity of operational aids, and to provide a method for evaluating the safety implications of the functions of proposed operational aids. After a discussion of the method evaluation now under study, this paper outlines this data collection to date

  19. Targeting Accuracy, Procedure Times and User Experience of 240 Experimental MRI Biopsies Guided by a Clinical Add-On Navigation System.

    Science.gov (United States)

    Busse, Harald; Riedel, Tim; Garnov, Nikita; Thörmer, Gregor; Kahn, Thomas; Moche, Michael

    2015-01-01

    MRI is of great clinical utility for the guidance of special diagnostic and therapeutic interventions. The majority of such procedures are performed iteratively ("in-and-out") in standard, closed-bore MRI systems with control imaging inside the bore and needle adjustments outside the bore. The fundamental limitations of such an approach have led to the development of various assistance techniques, from simple guidance tools to advanced navigation systems. The purpose of this work was to thoroughly assess the targeting accuracy, workflow and usability of a clinical add-on navigation solution on 240 simulated biopsies by different medical operators. Navigation relied on a virtual 3D MRI scene with real-time overlay of the optically tracked biopsy needle. Smart reference markers on a freely adjustable arm ensured proper registration. Twenty-four operators - attending (AR) and resident radiologists (RR) as well as medical students (MS) - performed well-controlled biopsies of 10 embedded model targets (mean diameter: 8.5 mm, insertion depths: 17-76 mm). Targeting accuracy, procedure times and 13 Likert scores on system performance were determined (strong agreement: 5.0). Differences in diagnostic success rates (AR: 93%, RR: 88%, MS: 81%) were not significant. In contrast, between-group differences in biopsy times (AR: 4:15, RR: 4:40, MS: 5:06 min:sec) differed significantly (p<0.01). Mean overall rating was 4.2. The average operator would use the system again (4.8) and stated that the outcome justifies the extra effort (4.4). Lowest agreement was reported for the robustness against external perturbations (2.8). The described combination of optical tracking technology with an automatic MRI registration appears to be sufficiently accurate for instrument guidance in a standard (closed-bore) MRI environment. High targeting accuracy and usability was demonstrated on a relatively large number of procedures and operators. Between groups with different expertise there were

  20. Targeting Accuracy, Procedure Times and User Experience of 240 Experimental MRI Biopsies Guided by a Clinical Add-On Navigation System.

    Directory of Open Access Journals (Sweden)

    Harald Busse

    Full Text Available MRI is of great clinical utility for the guidance of special diagnostic and therapeutic interventions. The majority of such procedures are performed iteratively ("in-and-out" in standard, closed-bore MRI systems with control imaging inside the bore and needle adjustments outside the bore. The fundamental limitations of such an approach have led to the development of various assistance techniques, from simple guidance tools to advanced navigation systems. The purpose of this work was to thoroughly assess the targeting accuracy, workflow and usability of a clinical add-on navigation solution on 240 simulated biopsies by different medical operators.Navigation relied on a virtual 3D MRI scene with real-time overlay of the optically tracked biopsy needle. Smart reference markers on a freely adjustable arm ensured proper registration. Twenty-four operators - attending (AR and resident radiologists (RR as well as medical students (MS - performed well-controlled biopsies of 10 embedded model targets (mean diameter: 8.5 mm, insertion depths: 17-76 mm. Targeting accuracy, procedure times and 13 Likert scores on system performance were determined (strong agreement: 5.0.Differences in diagnostic success rates (AR: 93%, RR: 88%, MS: 81% were not significant. In contrast, between-group differences in biopsy times (AR: 4:15, RR: 4:40, MS: 5:06 min:sec differed significantly (p<0.01. Mean overall rating was 4.2. The average operator would use the system again (4.8 and stated that the outcome justifies the extra effort (4.4. Lowest agreement was reported for the robustness against external perturbations (2.8.The described combination of optical tracking technology with an automatic MRI registration appears to be sufficiently accurate for instrument guidance in a standard (closed-bore MRI environment. High targeting accuracy and usability was demonstrated on a relatively large number of procedures and operators. Between groups with different expertise there were

  1. An overview of SST-1 diagnostics and results from recent campaigns

    International Nuclear Information System (INIS)

    Kumar, Ajai; Adhiya, Asha N.; Joshi, Hemchandra C.

    2015-01-01

    SST-1 is a large aspect ratio tokomak with superconducting magnets designed to operate in steady-state mode for around 1000 seconds. All essential diagnostics for the machine operation and advance diagnostics are commissioned in SST-1 during the different phases of its operation. This report describes the various diagnostics in SST-1 and the results of recent SST-1 campaign with Plasma Facing components. The chord averaged electron density of SST-1 plasma is recorded in the range of 2-5 x 10 12 /cc and the electron temperature is estimated around 100 eV. Various spectral line emissions from plasma and temporal evolutions of some of them have been recorded by spectroscopy diagnostics to understand the impurity behaviour in the SST-1 plasma. The radiation power loss and the power deposited on limiter has been estimated using bolometry and IR thermography respectively. Plasma evolution recorded using visible imaging diagnostics. The energy distribution of non-thermal electron has been characterised using LaBr spectrometer and NaI detector. This article will also be discussing about the possible additions and modification planned for the near future. (author)

  2. Inservice diagnostic methods for solenoid-operated valves

    International Nuclear Information System (INIS)

    Kryter, R.C.

    1993-01-01

    Solenoid-operated valves (SOVs) were studied at Oak Ridge National Laboratory as part of the USNRC Nuclear Plant Aging Research (NPAR) Program. The primary objective of the study was to identify, evaluate, and recommend methods for inspection, surveillance, monitoring, and maintenance of SOVs that can help ensure their operational readiness-that is, their ability to perform required safety functions under all anticipated operating conditions, since failure of one of these small and relatively inexpensive devices could have serious consequences under certain circumstances. An earlier (Phase 1) NPAR program study described SOV failure modes and causes and had identified measurable parameters thought to be linked to the progression of everpresent degradation mechanisms that may ultimately result in functional failure of the valve. Using this earlier work as a guide, the present (Phase 11) study focused on devising and then demonstrating the effectiveness of techniques and equipment with which to measure performance parameters that show promise for detecting the presence and trending the progress of such degradations before they reach a critical stage. Intrusive techniques requiring the addition of magnetic or acoustic sensors or the application of special test signals were investigated briefly, but major emphasis was placed on the examination of condition-indicating techniques that can be applied with minimal cost and impact on plant operation. Experimental results are presented that demonstrate the technical feasibility and practicality of the monitoring techniques assessed in the study, and recommendations for further work are provided

  3. Nanomedicine: Drug Delivery Systems and Nanoparticle Targeting

    International Nuclear Information System (INIS)

    Youn, Hye Won; Kang, Keon Wook; Chung, Jun Key; Lee, Dong Soo

    2008-01-01

    Applications of nanotechnology in the medical field have provided the fundamentals of tremendous improvement in precise diagnosis and customized therapy. Recent advances in nanomedicine have led to establish a new concept of theragnosis, which utilizes nanomedicines as a therapeutic and diagnostic tool at the same time. The development of high affinity nanoparticles with large surface area and functional groups multiplies diagnostic and therapeutic capacities. Considering the specific conditions related to the disease of individual patient, customized therapy requires the identification of disease target at the cellular and molecular level for reducing side effects and enhancing therapeutic efficiency. Well-designed nanoparticles can minimize unnecessary exposure of cytotoxic drugs and maximize targeted localization of administrated drugs. This review will focus on major pharmaceutical nanomaterials and nanoparticles as key components of designing and surface engineering for targeted theragnostic drug development

  4. MOLECULAR DIAGNOSTICS OF YERSINIA RUCKERI

    Directory of Open Access Journals (Sweden)

    Yu. Rud

    2014-06-01

    Full Text Available Purpose. The analysis of nucleotide sequences of the 16S rDNA gene of virulent strains of Yersinia ruckeri and to develop the method of molecular diagnostic of enteric redmouth disease. Methodology. By the method of CLUSTALW algorithm in MEGA software version 6.0 the nucleotide sequences of the 16S rDNA gene of virulent strains of Yersinia ruckeri were analysed. For development of molecular diagnostic of Y. ruckeri the method of polymerase chain reaction (PCR was used. Primer selection was carried out in software VectorNTI11 and on-line-service BLAST. The PCR products were investigated by the methods of sequencing and nucleotide analysis. Findings. Based on PCR assay the method of molecular diagnostic of enteric redmouth disease agent, bacterium Y. ruckeri was developed. It was shown that specific oligonucleotide primers generated PCR products in size of 600 base pairs. PCR products were investigated by the sequencing that showed right targeting of primers in reaction. Originality. Among high-conservative gene of 16S rDNA of Y. ruckeri the fragment of DNA was determined to which the specific primers for rapid diagnostic of virulent strains were selected. Practical Value. Rapid diagnostic of yersiniosis will allow to identify an agent of this infectious disease, bacterium Y. ruckeri, and to provide the prophylactic or medical measures in the fish farming of Ukraine.

  5. Hardware design of a microcomputer controlled diagnostic vacuum controller

    International Nuclear Information System (INIS)

    Marsala, R.J.

    1983-01-01

    The TFTR diagnostic vacuum controller (DVC) has been designed and built to control and monitor the pumps, valves and gauges which comprise a diagnostic vacuum system. The DVC is a microcomputer based self-contained controller with battery backup which may be controlled manually from front panel controls or remotely via CICADA. The DVC implements all pump and valve sequencing and provides protection against incorrect operation. There are presently two versions of the DVC operating on TFTR and a third version being used on the S-1 machine

  6. A flexible simulator for training an early fault diagnostic system

    International Nuclear Information System (INIS)

    Marsiletti, M.; Santinelli, A.; Zuenkov, M.; Poletykin, A.

    1997-01-01

    An early fault diagnostic system has been developed addressed to timely trouble shooting in process plants during any operational modes. The theory of this diagnostic system is related with the usage of learning methods for automatic generation of knowledge bases. This approach enables the conversion of ''cause→effect'' relations into ''effect→possible-causes'' ones. The diagnostic rules are derived from the operation of a plant simulator according to a specific procedure. Flexibility, accuracy and high speed are the major characteristics of the training simulator, used to generate the diagnostic knowledge base. The simulator structure is very flexible, being based on LEGO code but allowing the use of practically any kind of FORTRAN routines (recently also ACSL macros has been introduced) as plant modules: this permits, when needed, a very accurate description of the malfunctions the diagnostic system should ''known''. The high speed is useful to shorten the ''learning'' phase of the diagnostic system. The feasibility of the overall system has been assessed, using as reference plant the conventional Sampierdarena (Italy) power station, that is a combined cycle plant dedicated to produce both electrical and heat power. The hardware configuration of this prototype system was made up of a network of a Hewlett-Packard workstation and a Digital VAX-Station. The paper illustrates the basic structure of the simulator used for this diagnostic system training purpose, as well as the theoretical background on which the diagnostic system is based. Some evidence of the effectiveness of the concept through the application to Sampierdarena 40 MW cogeneration plant is reported. Finally an outline of an ongoing application to a WWER-1000 plant is given; the operating system is, in this case, UNIX. (author)

  7. 76 FR 23825 - Study Methodologies for Diagnostics in the Postmarket Setting; Public Workshop

    Science.gov (United States)

    2011-04-28

    ... understanding of the performance of diagnostics at the postmarket settings. II. Who is the target audience for... interested parties. The target audience is professionals in the scientific community with experience in...

  8. Diagnostics for induction accelerators

    International Nuclear Information System (INIS)

    Fessenden, T.J.

    1997-01-01

    The induction accelerator was conceived by N. C. Christofilos and first realized as the Astron accelerator that operated at Lawrence Livermore National Laboratory (LLNL) from the early 1960s to the end of 1975. This accelerator generated electron beams at energies near 6 MeV with typical currents of 600 Amperes in 400-ns pulses. The Advanced Test Accelerator (ATA) built at Livermore close-quote s Site 300 produced 10,000-Ampere beams with pulse widths of 70 ns at energies approaching 50 MeV. Several other electron and ion induction accelerators have been fabricated at LLNL and Lawrence Berkeley National Laboratory (LBNL). This paper reviews the principal diagnostics developed through efforts by scientists at both laboratories for measuring the current, position, energy, and emittance of beams generated by these high-current, short-pulse accelerators. Many of these diagnostics are closely related to those developed for other accelerators. However, the very fast and intense current pulses often require special diagnostic techniques and considerations. The physics and design of the more unique diagnostics developed for electron induction accelerators are presented and discussed in detail. copyright 1997 American Institute of Physics

  9. Diagnostics for pellet experiments

    International Nuclear Information System (INIS)

    Johnson, R.R.

    1978-01-01

    The target diagnostics which are being used and planned in current laser driven ICF Experiments are described. Most of these diagnostics can be easily applied to future ion-beam fusion experiments. The status of laser fusion diagnostics has been much improved in the last 5 years and further improvements can be expected and should be available when the first ICF experiments using ion beams are performed. As an example, x-ray temporal and spatial resolutions are now approximately 5 psec and 3 μm, which is approximately a factor of 4 better than the resolution reported in the first implosion experiments. As one plans ahead for ion-beam fusion experiments it should be emphasized that high yield experiments are easier to diagnose provided adequate shielding is employed. However, in the event that the first high yield experiments fail it will be necessary to have diagnostics available to determine where the problems lie. In laser fusion it is interesting to note that higher laser powers are required now for breakeven experiments than first anticipated, mainly because some aspects of the laser-interaction physics were not recognized until the experiments were carefully diagnosed. Thus as has been pointed out, it may be necessary to increase the energy of the ion-beam driver to enable us to do breakeven experiments with high confidence

  10. Neutron calorimeter as a fusion diagnostic

    International Nuclear Information System (INIS)

    Proctor, A.E.; Nieschmidt, E.B.

    1986-01-01

    A calorimeter is described which is applicable as a fusion neutron diagnostic. The device has the following distinct advantages: low sensitivity to thermal neutrons, large dynamic range, small mass resulting in fair time resolution, small physical size, independent calibration, little shielding required, no heat loss to surroundings, and low cost. The heat generation is provided by neutron induced fissions in a foil of 235 U or 238 U. The effects, advantages, and disadvantages of these target materials are discussed. The expected time resolution and dynamic range are estimated for both target materials

  11. Flexible human machine interface for process diagnostics

    International Nuclear Information System (INIS)

    Reifman, J.; Graham, G.E.; Wei, T.Y.C.; Brown, K.R.; Chin, R.Y.

    1996-01-01

    A flexible human machine interface to design and display graphical and textual process diagnostic information is presented. The system operates on different computer hardware platforms, including PCs under MS Windows and UNIX Workstations under X-Windows, in a client-server architecture. The interface system is customized for specific process applications in a graphical user interface development environment by overlaying the image of the process piping and instrumentation diagram with display objects that are highlighted in color during diagnostic display. Customization of the system is presented for Commonwealth Edison's Braidwood PWR Chemical and Volume Control System with transients simulated by a full-scale operator-training simulator and diagnosed by a computer-based system

  12. Diagnostic Accuracy of Multiparametric Magnetic Resonance Imaging and Fusion Guided Targeted Biopsy Evaluated by Transperineal Template Saturation Prostate Biopsy for the Detection and Characterization of Prostate Cancer.

    Science.gov (United States)

    Mortezavi, Ashkan; Märzendorfer, Olivia; Donati, Olivio F; Rizzi, Gianluca; Rupp, Niels J; Wettstein, Marian S; Gross, Oliver; Sulser, Tullio; Hermanns, Thomas; Eberli, Daniel

    2018-02-21

    We evaluated the diagnostic accuracy of multiparametric magnetic resonance imaging and multiparametric magnetic resonance imaging/transrectal ultrasound fusion guided targeted biopsy against that of transperineal template saturation prostate biopsy to detect prostate cancer. We retrospectively analyzed the records of 415 men who consecutively presented for prostate biopsy between November 2014 and September 2016 at our tertiary care center. Multiparametric magnetic resonance imaging was performed using a 3 Tesla device without an endorectal coil, followed by transperineal template saturation prostate biopsy with the BiopSee® fusion system. Additional fusion guided targeted biopsy was done in men with a suspicious lesion on multiparametric magnetic resonance imaging, defined as Likert score 3 to 5. Any Gleason pattern 4 was defined as clinically significant prostate cancer. The detection rates of multiparametric magnetic resonance imaging and fusion guided targeted biopsy were compared with the detection rate of transperineal template saturation prostate biopsy using the McNemar test. We obtained a median of 40 (range 30 to 55) and 3 (range 2 to 4) transperineal template saturation prostate biopsy and fusion guided targeted biopsy cores, respectively. Of the 124 patients (29.9%) without a suspicious lesion on multiparametric magnetic resonance imaging 32 (25.8%) were found to have clinically significant prostate cancer on transperineal template saturation prostate biopsy. Of the 291 patients (70.1%) with a Likert score of 3 to 5 clinically significant prostate cancer was detected in 129 (44.3%) by multiparametric magnetic resonance imaging fusion guided targeted biopsy, in 176 (60.5%) by transperineal template saturation prostate biopsy and in 187 (64.3%) by the combined approach. Overall 58 cases (19.9%) of clinically significant prostate cancer would have been missed if fusion guided targeted biopsy had been performed exclusively. The sensitivity of

  13. 30 CFR 250.522 - When do I have to repeat casing diagnostic testing?

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false When do I have to repeat casing diagnostic... Operations Casing Pressure Management § 250.522 When do I have to repeat casing diagnostic testing? Casing diagnostic testing must be repeated according to the following table: When * * * you must repeat diagnostic...

  14. Expert system for fast reactor diagnostic

    International Nuclear Information System (INIS)

    Parcy, J.P.

    1982-09-01

    A general description of expert systems is given. The operation of a fast reactor is reviewed. The expert system to the diagnosis of breakdowns limited to the reactor core. The structure of the system is described: specification of the diagnostics; structure of the data bank and evaluation of the rules; specification of the prediagnostics and evaluation; explanation of the diagnostics; time evolution of the system; comparison with other expert systems. Applications to some cases of faults are finally presented [fr

  15. WE-AB-206-01: Diagnostic Ultrasound Imaging Quality Assurance

    Energy Technology Data Exchange (ETDEWEB)

    Zagzebski, J. [University of Wisconsin (United States)

    2016-06-15

    The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. The goal of this ultrasound hands-on workshop is to demonstrate quality control (QC) testing in diagnostic ultrasound and to provide updates in ACR ultrasound accreditation requirements. The first half of this workshop will include two presentations reviewing diagnostic ultrasound QA/QC and ACR ultrasound accreditation requirements. The second half of the workshop will include live demonstrations of basic QC tests. An array of ultrasound testing phantoms and ultrasound scanners will be available for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations and on-site instructors. The targeted attendees are medical physicists in diagnostic imaging. Learning Objectives: Gain familiarity with common elements of a QA/QC program for diagnostic ultrasound imaging dentify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools Learn ACR ultrasound accreditation requirements Jennifer Walter is an employee of American College of Radiology on Ultrasound Accreditation.

  16. WE-AB-206-01: Diagnostic Ultrasound Imaging Quality Assurance

    International Nuclear Information System (INIS)

    Zagzebski, J.

    2016-01-01

    The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. The goal of this ultrasound hands-on workshop is to demonstrate quality control (QC) testing in diagnostic ultrasound and to provide updates in ACR ultrasound accreditation requirements. The first half of this workshop will include two presentations reviewing diagnostic ultrasound QA/QC and ACR ultrasound accreditation requirements. The second half of the workshop will include live demonstrations of basic QC tests. An array of ultrasound testing phantoms and ultrasound scanners will be available for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations and on-site instructors. The targeted attendees are medical physicists in diagnostic imaging. Learning Objectives: Gain familiarity with common elements of a QA/QC program for diagnostic ultrasound imaging dentify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools Learn ACR ultrasound accreditation requirements Jennifer Walter is an employee of American College of Radiology on Ultrasound Accreditation.

  17. Advanced Light Source beam diagnostics systems

    International Nuclear Information System (INIS)

    Hinkson, J.

    1993-10-01

    The Advanced Light Source (ALS), a third-generation synchrotron light source, has been recently commissioned. Beam diagnostics were very important to the success of the operation. Each diagnostic system is described in this paper along with detailed discussion of its performance. Some of the systems have been in operation for two years. Others, in the storage ring, have not yet been fully commissioned. These systems were, however, working well enough to provide the essential information needed to store beam. The devices described in this paper include wall current monitors, a beam charge monitor, a 50 ohm Faraday cup, DC current transformers, broad-hand striplines, fluorescence screens, beam collimators and scrapers, and beam position monitors. Also, the means by which waveforms are digitized and displayed in the control room is discussed

  18. Chapter 7: Diagnostics [Progress in the ITER Physics Basis (PIPB)

    International Nuclear Information System (INIS)

    Donne, A.J.H.; Costley, A.E.; Barnsley, R.

    2007-01-01

    In order to support the operation of ITER and the planned experimental programme an extensive set of plasma and first wall measurements will be required. The number and type of required measurements will be similar to those made on the present-day large tokamaks while the specification of the measurements-time and spatial resolutions, etc-will in some cases be more stringent. Many of the measurements will be used in the real time control of the plasma driving a requirement for very high reliability in the systems (diagnostics) that provide the measurements. The implementation of diagnostic systems on ITER is a substantial challenge. Because of the harsh environment (high levels of neutron and gamma fluxes, neutron heating, particle bombardment) diagnostic system selection and design has to cope with a range of phenomena not previously encountered in diagnostic design. Extensive design and R and D is needed to prepare the systems. In some cases the environmental difficulties are so severe that new diagnostic techniques are required. The starting point in the development of diagnostics for ITER is to define the measurement requirements and develop their justification. It is necessary to include all the plasma parameters needed to support the basic and advanced operation (including active control) of the device, machine protection and also those needed to support the physics programme. Once the requirements are defined, the appropriate (combination of) diagnostic techniques can be selected and their implementation onto the tokamak can be developed. The selected list of diagnostics is an important guideline for identifying dedicated research and development needs in the area of ITER diagnostics. This paper gives a comprehensive overview of recent progress in the field of ITER diagnostics with emphasis on the implementation issues. After a discussion of the measurement requirements for plasma parameters in ITER and their justifications, recent progress in the field of

  19. Misfire: An Operational Critique of Operation Iraqi Freedom (OIF) Targeting Strategy

    National Research Council Canada - National Science Library

    Martin, John D

    2005-01-01

    ...." However, while PGMs were instrumental in accomplishing the primary national-strategic objective of regime removal in OIF, targeting concentrated exclusively on leadership, command and control (C2...

  20. Diagnostics carried by a light multipurpose deployer for vacuum vessel interventions

    Energy Technology Data Exchange (ETDEWEB)

    Houry, M., E-mail: Michael.houry@cea.fr [CEA-IRFM, F-13108 Saint-Paul-Lez-Durance (France); Gargiulo, L.; Balorin, C.; Bruno, V.; Keller, D.; Roche, H. [CEA-IRFM, F-13108 Saint-Paul-Lez-Durance (France); Kammerer, N.; Measson, Y. [CEA, LIST, F-92265 Fontenay-aux-Roses (France); Carrel, F.; Schoepff, V. [CEA, LIST, F-91191 Gif-sur-Yvette (France)

    2011-10-15

    ITER will greatly rely on remote-handling operations to accomplish its scientific missions. Robotic systems will also be required to operate inside vacuum vessels in order to limit or replace human access, to intervene quickly between experimental sessions for in-vessel inspections and measurements, and to preserve the machine conditioning and thus improve machine availability. In this prospect, a multipurpose carrier prototype called Articulated Inspection Arm (AIA) was developed by CEA laboratories within the European work program. With an embedded camera, it successfully demonstrated close inspection feasibility inside Tore Supra tokamak. The AIA robot was designed for mini-invasive operations with interchangeable diagnostics to be plugged at its head. This covers various applications for the safety, the operation and the scientific mission (in-vessel inspection, plasma diagnostics calibrations or inner components analysis and treatments). This paper presents recent analysis and results obtain with diagnostics developed by CEA for in-vessel remote-handling intervention.

  1. Diagnostics carried by a light multipurpose deployer for vacuum vessel interventions

    International Nuclear Information System (INIS)

    Houry, M.; Gargiulo, L.; Balorin, C.; Bruno, V.; Keller, D.; Roche, H.; Kammerer, N.; Measson, Y.; Carrel, F.; Schoepff, V.

    2011-01-01

    ITER will greatly rely on remote-handling operations to accomplish its scientific missions. Robotic systems will also be required to operate inside vacuum vessels in order to limit or replace human access, to intervene quickly between experimental sessions for in-vessel inspections and measurements, and to preserve the machine conditioning and thus improve machine availability. In this prospect, a multipurpose carrier prototype called Articulated Inspection Arm (AIA) was developed by CEA laboratories within the European work program. With an embedded camera, it successfully demonstrated close inspection feasibility inside Tore Supra tokamak. The AIA robot was designed for mini-invasive operations with interchangeable diagnostics to be plugged at its head. This covers various applications for the safety, the operation and the scientific mission (in-vessel inspection, plasma diagnostics calibrations or inner components analysis and treatments). This paper presents recent analysis and results obtain with diagnostics developed by CEA for in-vessel remote-handling intervention.

  2. Expert system applications in support of system diagnostics and prognostics at EBR-II

    International Nuclear Information System (INIS)

    Lehto, W.K.; Gross, K.C.

    1989-01-01

    Expert systems have been developed to aid in the monitoring and diagnostics of the Experimental Breeder Reactor-II (EBR-II) at the Idaho National Engineering Laboratory (INEL) in Idaho Falls, Idaho. Systems have been developed for failed fuel surveillance and diagnostics and reactor coolant pump monitoring and diagnostics. A third project is being done jointly by ANL-W and EG ampersand G Idaho to develop a transient analysis system to enhance overall plant diagnostic and prognostic capability. The failed fuel surveillance and diagnosis system monitors, processes, and interprets information from nine key plant sensors. It displays to the reactor operator diagnostic information needed to make proper decisions regarding technical specification conformance during reactor operation with failed fuel. 8 refs., 9 figs., 2 tabs

  3. Diagnostic systems developed in NPPRI (VUJE) Trnava Inc. for NPPs

    International Nuclear Information System (INIS)

    Kucharek, P.

    1998-01-01

    Since foundation of Nuclear Power Plant Research Institute (NPPRI) in 1977, the department of diagnostics has been dealt with problems related to the theoretical, practical and organizatory questions of operational diagnostics connected with PWR type nuclear components. This department acts directly in locality of NPP Jaslovske Bohunice, but there are performances for all NPP in Slovak or Czech Republic (Dukovany, Mochovce, and Temelin). Besides direct services and achievements for NPP there exist advisory, experts and research activities for the government and supervising authorities, too. In 1985, NPPRI began systematically construct and verify technical means for operational diagnostics of main circulating pumps (MCP) with good results, based on own rich practical experiences and contacts with organisations abroad. In recent years NPPRI as one of recognised qualified and authorised institutions in Slovak Republic has begun to develop a new generation of diagnostic systems for NPP on high technical level but with lower procuring costs in comparison with western countries products. This contribution deals with four following types of diagnostic systems which were not only developed but also delivered and installed on Slovak and Czech nuclear units: - Loose part monitoring system (LPMS), - Humidity monitoring system (HUMON), - Reactor coolant pumps monitoring system (RCPMS), - Primary circuit vibration monitoring system (VMS). Main features of new generation from middle of 1990's of these systems are described in this paper and operational experiences with them too. (author)

  4. The IHS diagnostic X-ray equipment radiation protection program

    International Nuclear Information System (INIS)

    Knapp, A.; Byrns, G.; Suleiman, O.

    1994-01-01

    The Indian Health Service (IHS) operates or contracts with Tribal groups to operate 50 hospitals and approximately 165 primary ambulatory care centers. These facilities contain approximately 275 medical and 800 dental diagnostic x-ray machines. IHS environmental health personnel in collaboration with the Food and Drug Administration's (FDA) Center for Devices and Radiological Health (CDRH) developed a diagnostic x-ray protection program including standard survey procedures and menu-driven calculations software. Important features of the program include the evaluation of equipment performance collection of average patient entrance skin exposure (ESE) measurements for selected procedures, and quality assurance. The ESE data, collected using the National Evaluation of X-ray Trends (NEXT) protocol, will be presented. The IHS Diagnostic X-ray Radiation Protection Program is dynamic and is adapting to changes in technology and workload

  5. Optical fibres for fusion plasma diagnostics systems

    International Nuclear Information System (INIS)

    Brichard, B.

    2005-01-01

    The condition to achieve and maintain the ignition of a thermonuclear fusion plasma ignition calls for the construction of a large scale fusion reactor, namely ITER. This reactor is designed to deliver an average fusion power of 500 MW. The burning of fusion plasma at such high power level will release a tremendous amount of energy in the form of particle fluxes and ionising radiation. This energy release, primarily absorbed by the plasma facing components, can significantly degrade the performances of the plasma diagnostic equipment surrounding the machine. To ensure a correct operation of the Tokamak we need to develop highly radiation-resistance devices. In plasma diagnostic systems, optical fibre is viewed as a convenient tool to transport light from the plasma edge to the diagnostic area. Radiation affects the optical performances of the fibre mainly by the occurrence of radiation-induced absorption and luminescence. Both effects degrade the light signal used for plasma diagnostic. SCK-CEN is currently assessing radiation-resistant glasses for optical fibres and is developing the associated qualification procedure. The main objectives of this study were to increase the lifetime of optical components in high radiation background and to develop a radiation resistance optical fibre capable to operate in the radiation background of ITER

  6. Cancer pancreatis, diagnostic procedures

    International Nuclear Information System (INIS)

    Graadal, Oe.; Schlichting, E.; Aasen, A.O.; Stadaas, J.O.

    1990-01-01

    151 patients treated for carcinoma of the pancreas at Ullevaal Hospital (Oslo University) during the period 1980-89 were studied. The most common initial symptom was abdominal pain. Other frequent debut symptoms were loss of weight and jaundice. ERCP and PTC were found to be the best diagnostic procedures. CT or ultrasonography were normal in 10-20% of the patients. Nearly all tumors of the pancreas were found by the ERCP procedure. Also angiography was used to evaluate operability of the pancreas tumor, but was found to be a very uncertain diagnostic method. This method will not be used in the future evaluation of patients with cancer of the pancreas. 13 refs., 1 fig., 2 tabs

  7. Comparative guide to emerging diagnostic tools for large commercial HVAC systems

    Energy Technology Data Exchange (ETDEWEB)

    Friedman, Hannah; Piette, Mary Ann

    2001-05-01

    This guide compares emerging diagnostic software tools that aid detection and diagnosis of operational problems for large HVAC systems. We have evaluated six tools for use with energy management control system (EMCS) or other monitoring data. The diagnostic tools summarize relevant performance metrics, display plots for manual analysis, and perform automated diagnostic procedures. Our comparative analysis presents nine summary tables with supporting explanatory text and includes sample diagnostic screens for each tool.

  8. Autonomous Diagnostic Imaging Performed by Untrained Operators using Augmented Reality as a Form of "Just-in-Time" Training

    Science.gov (United States)

    Martin, D. S.; Wang, L.; Laurie, S. S.; Lee, S. M. C.; Fleischer, A. C.; Gibson, C. R.; Stenger, M. B.

    2017-01-01

    We will address the Human Factors and Performance Team, "Risk of performance errors due to training deficiencies" by improving the JIT training materials for ultrasound and OCT imaging by providing advanced guidance in a detailed, timely, and user-friendly manner. Specifically, we will (1) develop an audio-visual tutorial using AR that guides non-experts through an abdominal trauma ultrasound protocol; (2) develop an audio-visual tutorial using AR to guide an untrained operator through the acquisition of OCT images; (3) evaluate the quality of abdominal ultrasound and OCT images acquired by untrained operators using AR guidance compared to images acquired using traditional JIT techniques (laptop-based training conducted before image acquisition); and (4) compare the time required to complete imaging studies using AR tutorials with images acquired using current JIT practices to identify areas for time efficiency improvements. Two groups of subjects will be recruited to participate in this study. Operator-subjects, without previous experience in ultrasound or OCT, will be asked to perform both procedures using either the JIT training with AR technology or the traditional JIT training via laptop. Images acquired by inexperienced operator-subjects will be scored by experts in that imaging modality for diagnostic and research quality; experts will be blinded to the form of JIT used to acquire the images. Operator-subjects also will be asked to submit feedback to improve the training modules used during the scans to improve future training modules. Scanned-subjects will be a small group individuals from whom all images will be acquired.

  9. Autonomous Diagnostic Imaging Performed by Untrained Operator Using Augmented Reality as a Form of "Just-in-Time" Training

    Science.gov (United States)

    Martin, David S.; Wang, Lui; Laurie, Steven S.; Lee, Stuart M. C.; Stenger, Michael B.

    2017-01-01

    We will address the Human Factors and Performance Team, "Risk of performance errors due to training deficiencies" by improving the JIT training materials for ultrasound and OCT imaging by providing advanced guidance in a detailed, timely, and user-friendly manner. Specifically, we will (1) develop an audio-visual tutorial using AR that guides non-experts through an abdominal trauma ultrasound protocol; (2) develop an audio-visual tutorial using AR to guide an untrained operator through the acquisition of OCT images; (3) evaluate the quality of abdominal ultrasound and OCT images acquired by untrained operators using AR guidance compared to images acquired using traditional JIT techniques (laptop-based training conducted before image acquisition); and (4) compare the time required to complete imaging studies using AR tutorials with images acquired using current JIT practices to identify areas for time efficiency improvements. Two groups of subjects will be recruited to participate in this study. Operator-subjects, without previous experience in ultrasound or OCT, will be asked to perform both procedures using either the JIT training with AR technology or the traditional JIT training via laptop. Images acquired by inexperienced operator-subjects will be scored by experts in that imaging modality for diagnostic and research quality; experts will be blinded to the form of JIT used to acquire the images. Operator-subjects also will be asked to submit feedback to improve the training modules used during the scans to improve future training modules. Scanned-subjects will be a small group individuals from whom all images will be acquired.

  10. Data mining approach to model the diagnostic service management.

    Science.gov (United States)

    Lee, Sun-Mi; Lee, Ae-Kyung; Park, Il-Su

    2006-01-01

    Korea has National Health Insurance Program operated by the government-owned National Health Insurance Corporation, and diagnostic services are provided every two year for the insured and their family members. Developing a customer relationship management (CRM) system using data mining technology would be useful to improve the performance of diagnostic service programs. Under these circumstances, this study developed a model for diagnostic service management taking into account the characteristics of subjects using a data mining approach. This study could be further used to develop an automated CRM system contributing to the increase in the rate of receiving diagnostic services.

  11. Molecular diagnostics of periodontitis

    Directory of Open Access Journals (Sweden)

    Izabela Korona-Głowniak

    2017-01-01

    Full Text Available The microorganisms that form dental plaque are the main cause of periodontitis. Their identification and the understanding of the complex relationships and interactions that involve these microorganisms, environmental factors and the host’s health status enable improvement in diagnostics and targeted therapy in patients with periodontitis. To this end, molecular diagnostics techniques (both techniques based on the polymerase chain reaction and those involving nucleic acid analysis via hybridization come increasingly into use. On the basis of a literature review, the following methods are presented: polymerase chain reaction (PCR, real-time polymerase chain reaction (real-time PCR, 16S rRNA-encoding gene sequencing, checkerboard and reverse-capture checkerboard hybridization, microarrays, denaturing gradient gel electrophoresis (DGGE, temperature gradient gel electrophoresis (TGGE, as well as terminal restriction fragment length polymorphism (TRFLP and next generation sequencing (NGS. The advantages and drawbacks of each method in the examination of periopathogens are indicated. The techniques listed above allow fast detection of even small quantities of pathogen present in diagnostic material and prove particularly useful to detect microorganisms that are difficult or impossible to grow in a laboratory.

  12. Integrated Laser-Target Interaction Experiments on the RAL Petawatt Laser

    International Nuclear Information System (INIS)

    Patel, P. K.; Key, M. H.; Mackinnon, A. J.; Akli, K.; Berry, R.; Borghesi, M.; Brummit, P. A.; Chambers, D.; Clarke, R. J.; Damian, C.; Chen, H.; Eagleton, R.; Freeman, R.; Glenzer, S.; Gregori, G.; Heathcote, R.; Izumi, N.; Kar, S.; King, J. A.; Kock, J.; Kuba, J.; May, M.; Moon, S.; Neely, D.; Neville, D. R.; Nikroo, A.; Niles, A.; Pasley, J.; Patel, N.; Park, H. S.; Romagnani, L.; Shepherd, R.; Snavely, R. A.; Stephens, R.; Stoeckl, C.; Storm, M.; Theobald, W.; Van Maren, R.; Wilks, S. C.; Zhang, B.

    2005-01-01

    We report on two recent experimental campaigns performed on the new Petawatt laser at the Rutherford Appleton Laboratory in the UK.The laser has recently demonstrated performance characteristics of 400 J of laser energy being delivered on target in a sub 400 fs pulse, reaching a peak focal intensity on the order of 10''21 W/cm''2. The experiments covered multiplic areas of investigation including hot electron transport in planar foil and cone focus geometries, relativistic laser-solid interactions proton beam focusing and heating, and high energy K-alpha production and radiography. A somewhat novel approach was taken to the experiments in that all of the diagnostics required for the different areas of study were fielded simultaneously and operated on all shots. Thus, we were able to obtain extensive sets of measurements on a single-shot basis which provides significant benefit to our understanding of the laser-target interaction conditions and plasma properties. (Author)

  13. Training diagnostic skills for nuclear power plants

    International Nuclear Information System (INIS)

    Goodstein, L.P.

    1986-11-01

    Operators of large-scale industrial process plants such as nuclear power stations and chemical plants are faced with a critical and complex task when confronted with disturbances in normal operation caused by technical failures or mainte- nances errors. Great care must be taken to prepare and support the operators during such situations. Procedural systems are provided, trained on full-scale highfidelity simulators is often a prerequisite and decision-support systems are starting to be incorporated, especially in modern control rooms. During recent years, it has become increasingly clear from ''real-life'' studies in complex production and transport industries that professional highly skilled troubleshooters can develop effective general purpose search strategies for locating and dealing with faults and, most importantly, with new and not previously experienced faults. This research has indicated that means for training of these general diagnostic abilities can be developed. In addition, other work has dealt with the problem of observing and analyzing operator behaviour in coping with disturbances. The NKA/LIT-4 project has continued these efforts in studying methods for training diagnostic skills as well as for observing and testing operator behaviour on training simulators. (author)

  14. HTCAP-1: a program for calcuating operating temperatures in HFIR target irradiation experiments

    International Nuclear Information System (INIS)

    Kania, M.J.; Howard, A.M.

    1980-06-01

    The thermal modeling code, HTCAP-1, calculates in-reactor operating temperatures of fueled specimens contained in the High Flux Isotope Reactor (HFIR) target irradiation experiments (HT-series). Temperature calculations are made for loose particle and bonded fuel rod specimens. Maximum particle surface temperatures are calculated for the loose particles and centerline and surface temperatures for the fuel rods. Three computational models are employed to determine fission heat generation rates, capsule heat transfer analysis, and specimen temperatures. This report is also intended to be a users' manual, and the application of HTCAP-1 to the HT-34 irradiation capsule is presented

  15. Technology strategy for integrated operations and real time reservoir management; Technology Target Areas; TTA5 - Integrated operations and RTRM

    Energy Technology Data Exchange (ETDEWEB)

    2007-07-01

    In Norway Integrated Operations (IO) is a concept which in the first phase (G1) has been used to describe how to integrate processes and people onshore and offshore using ICT solutions and facilities that improve onshore's ability to support offshore operationally. The second generation (G2) Integrated Operations aims to help operators utilize vendors' core competencies and services more efficiently. Utilizing digital services and vendor products, operators will be able to update reservoir models, drilling targets and well trajectories as wells are drilled, manage well completions remotely, optimize production from reservoir to export lines, and implement condition-based maintenance concepts. The total impact on production, recovery rates, costs and safety will be profound. When the international petroleum business moves to the Arctic region the setting is very different from what is the case on the Norwegian Continental Shelf (NCS) and new challenges will arise. The Norwegian Ministry of Environment has recently issued an Integrated Management Plan for the Barents Sea where one focus is on 'Monitoring of the Marine Environment in the North'. The Government aims to establish a new and more coordinated system for monitoring the marine ecosystems in the north. A representative group consisting of the major Operators, the Service Industry, Academia and the Authorities have developed the enclosed strategy for the OG21 Integrated Operations and Real Time Reservoir Management (IO and RTRM) Technology Target Area (TTA). Major technology and work process research and development gaps have been identified in several areas: Bandwidth down-hole to surface; Sensor development including Nano-technology; Cross discipline use of Visualisation, Simulation and model development particularly in Drilling and Reservoir management areas; Software development in terms of data handling, model updating and calculation speed; Enabling reliable and robust communications particularly for

  16. Technology strategy for integrated operations and real time reservoir management; Technology Target Areas; TTA5 - Integrated operations and RTRM

    Energy Technology Data Exchange (ETDEWEB)

    2007-07-01

    In Norway Integrated Operations (IO) is a concept which in the first phase (G1) has been used to describe how to integrate processes and people onshore and offshore using ICT solutions and facilities that improve onshore's ability to support offshore operationally. The second generation (G2) Integrated Operations aims to help operators utilize vendors' core competencies and services more efficiently. Utilizing digital services and vendor products, operators will be able to update reservoir models, drilling targets and well trajectories as wells are drilled, manage well completions remotely, optimize production from reservoir to export lines, and implement condition-based maintenance concepts. The total impact on production, recovery rates, costs and safety will be profound. When the international petroleum business moves to the Arctic region the setting is very different from what is the case on the Norwegian Continental Shelf (NCS) and new challenges will arise. The Norwegian Ministry of Environment has recently issued an Integrated Management Plan for the Barents Sea where one focus is on 'Monitoring of the Marine Environment in the North'. The Government aims to establish a new and more coordinated system for monitoring the marine ecosystems in the north. A representative group consisting of the major Operators, the Service Industry, Academia and the Authorities have developed the enclosed strategy for the OG21 Integrated Operations and Real Time Reservoir Management (IO and RTRM) Technology Target Area (TTA). Major technology and work process research and development gaps have been identified in several areas: Bandwidth down-hole to surface; Sensor development including Nano-technology; Cross discipline use of Visualisation, Simulation and model development particularly in Drilling and Reservoir management areas; Software development in terms of data handling, model updating and calculation speed; Enabling reliable and robust communications

  17. Preventive maintenance program of motorized operated valves (MOV) at Cernavoda NPP

    International Nuclear Information System (INIS)

    Groza, M.; Moldoveanu, Edy

    2001-01-01

    This is a Power Point presentation. The following objectives are addressed: A. Determine the target of MOV program; B. Define the strategy for MOV; C. Establish the MOV program execution phases; D. Identification of key parameters; E. Examples. The target of MOV program is to improve the safety by ensuring the adequacy of safety valves and the reliability of safety equipment and, subsequently, to ensure the economic operation of the plant. Consequences of MV malfunction are indicated. The strategy for MOV program development is both general, namely, to define the minimal requirements of preventive /corrective maintenance activities for all MOV's according to design/ manufacture specification and particular, namely to identify MV's specific problems and the need for increasing/decreasing the preventing maintenance tasks or frequency established in 'general' MOV program. Strategy for MOV program development implies: - Establish MOV program applicability; - Develop diagnostic strategy (define key parameters ); - Perform program for engineering review; - Establish program for preventive maintenance; - Revise procedures for operating and maintenance tests; - Dynamic evaluation of MOV. The program execution phases are listed as follows: 1. Perform risk assessment of the MOV's to determine criticality level (program applicability); 2. Collect data to fill in MOV Application Data Sheet; 3. Perform engineering review to determine functional parameters acceptable range and determine key parameters; 4. Analysis for maintenance tasks / frequencies selection and determination of implementing actions (engineer review); 5. Prepare work packages for availability confirmation; 6. Schedule and plan corrective actions or provide input to other programs; 7. Schedule and plan implementing actions in preparation for program field execution; 8. Program field implementation; 9. Program monitoring, evaluation and optimization. The criteria defining the key operational and maintenance

  18. A single blood test adjusted for different liver fibrosis targets improves fibrosis staging and especially cirrhosis diagnosis.

    Science.gov (United States)

    Calès, Paul; Boursier, Jérôme; Oberti, Frédéric; Moal, Valérie; Fouchard Hubert, Isabelle; Bertrais, Sandrine; Hunault, Gilles; Rousselet, Marie Christine

    2018-04-01

    Fibrosis blood tests are usually developed using significant fibrosis, which is a unique diagnostic target; however, these tests are employed for other diagnostic targets, such as cirrhosis. We aimed to improve fibrosis staging accuracy by simultaneously targeting biomarkers for several diagnostic targets. A total of 3,809 patients were included, comprising 1,012 individuals with chronic hepatitis C (CHC) into a derivation population and 2,797 individuals into validation populations of different etiologies (CHC, chronic hepatitis B, human immunodeficiency virus/CHC, nonalcoholic fatty liver disease, alcohol) using Metavir fibrosis stages as reference. FibroMeter biomarkers were targeted for different fibrosis-stage combinations into classical scores by logistic regression. Independent scores were combined into a single score reflecting Metavir stages by linear regression and called Multi-FibroMeter Version Second Generation (V2G). The primary objective was to combine the advantages of a test targeted for significant fibrosis (FibroMeter V2G ) with those of a test targeted for cirrhosis (CirrhoMeter V2G ). In the derivation CHC population, we first compared Multi-FibroMeter V2G to FibroMeter V2G and observed significant increases in the cirrhosis area under the receiver operating characteristic curve (AUROC), Obuchowski index (reflecting all fibrosis-stage AUROCs), and classification metric (six classes expressed as a correctly classified percentage) and a nonsignificant increase in significant fibrosis AUROC. Thereafter, we compared it to CirroMeter V2G and observed a nonsignificant increase in the cirrhosis AUROC. In all 3,809 patients, respective accuracies for Multi-FibroMeter V2G and FibroMeter V2G were the following: cirrhosis AUROC, 0.906 versus 0.878 ( P fibrosis AUROC, 0.833 versus 0.832 ( P = 0.366). Multi-FibroMeter V2G had the highest correlation with the area of portoseptal fibrosis and the highest reproducibility over time. Correct classification rates

  19. The Diagnostic System of A – 604 Automatic Transmission

    Directory of Open Access Journals (Sweden)

    Czaban Jaroslaw

    2014-09-01

    Full Text Available Automatic gearbox gains increasing popularity in Europe. Little interest in diagnosis of such type of transmission in Poland results from the fact of small share in the whole market of operated cars, so there is a lack of availability of special diagnostic devices. These factors cause issues of expensive repairs, often involving a replacement of subassembly to new or aftermarket one. To a small extent some prophylactic diagnostic tests are conducted, which can eliminate future gearbox system failures. In the paper, the proposition of diagnostic system of popular A - 604 gearbox was presented. The authors are seeking for the possibility of using such type of devices to functional elaboration of gearboxes after renovation. The built system pursues the drive of the researched object, connected with simulated load, where special controller, replacing the original one, is responsible for controlling gearbox operation. This way is used to evaluate the mechanic and hydraulic parts' state. Analysis of signal runs, registered during measurements lets conclude about operation correctness, where as comparison with stock data verifies the technical state of an automatic gearbox.

  20. Implications of improved diagnostic imaging of small nodal metastases in head and neck cancer: Radiotherapy target volume transformation and dose de-escalation.

    Science.gov (United States)

    van den Bosch, Sven; Vogel, Wouter V; Raaijmakers, Cornelis P; Dijkema, Tim; Terhaard, Chris H J; Al-Mamgani, Abrahim; Kaanders, Johannes H A M

    2018-05-03

    Diagnostic imaging continues to evolve, and now has unprecedented accuracy for detecting small nodal metastasis. This influences the tumor load in elective target volumes and subsequently has consequences for the radiotherapy dose required to control disease in these volumes. Small metastases that used to remain subclinical and were included in elective volumes, will nowadays be detected and included in high-dose volumes. Consequentially, high-dose volumes will more often contain low-volume disease. These target volume transformations lead to changes in the tumor burden in elective and "gross" tumor volumes with implications for the radiotherapy dose prescribed to these volumes. For head and neck tumors, nodal staging has evolved from mere palpation to combinations of high-resolution imaging modalities. A traditional nodal gross tumor volume in the neck typically had a minimum diameter of 10-15 mm, while nowadays much smaller tumor deposits are detected in lymph nodes. However, the current dose levels for elective nodal irradiation were empirically determined in the 1950s, and have not changed since. In this report the radiobiological consequences of target volume transformation caused by modern imaging of the neck are evaluated, and theoretically derived reductions of dose in radiotherapy for head and neck cancer are proposed. The concept of target volume transformation and subsequent strategies for dose adaptation applies to many other tumor types as well. Awareness of this concept may result in new strategies for target definition and selection of dose levels with the aim to provide optimal tumor control with less toxicity. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  1. Verification and Diagnostics Framework in ATLAS Trigger/DAQ

    CERN Document Server

    Barczyk, M.; Caprini, M.; Da Silva Conceicao, J.; Dobson, M.; Flammer, J.; Jones, R.; Kazarov, A.; Kolos, S.; Liko, D.; Lucio, L.; Mapelli, L.; Soloviev, I.; Hart, R.; Amorim, A.; Klose, D.; Lima, J.; Pedro, J.; Wolters, H.; Badescu, E.; Alexandrov, I.; Kotov, V.; Mineev, M.; Ryabov, Yu.; Ryabov, Yu.

    2003-01-01

    Trigger and data acquisition (TDAQ) systems for modern HEP experiments are composed of thousands of hardware and software components depending on each other in a very complex manner. Typically, such systems are operated by non-expert shift operators, which are not aware of system functionality details. It is therefore necessary to help the operator to control the system and to minimize system down-time by providing knowledge-based facilities for automatic testing and verification of system components and also for error diagnostics and recovery. For this purpose, a verification and diagnostic framework was developed in the scope of ATLAS TDAQ. The verification functionality of the framework allows developers to configure simple low-level tests for any component in a TDAQ configuration. The test can be configured as one or more processes running on different hosts. The framework organizes tests in sequences, using knowledge about components hierarchy and dependencies, and allowing the operator to verify the fun...

  2. Internal targets for LEAR

    International Nuclear Information System (INIS)

    Kilian, K.; Gspann, J.; Mohl, D.; Poth, H.

    1984-01-01

    This chapter considers the use of thin internal targets in conjunction with phase-space cooling at the Low-Energy Antiproton Ring (LEAR). Topics considered include the merits of internal target operation; the most efficient use of antiprotons and of proton synchrotron (PS) protons, highest center-of-mass (c.m.) energy resolution; highest angular resolution and access to extreme angles; the transparent environment for all reaction products; a windowless source and pure targets; highest luminosity and count rates; access to lowest energies with increasing resolution; internal target thickness and vacuum requirements; required cooling performance; and modes of operation. It is demonstrated that an internal target in conjunction with phase-space cooling has the potential of better performance in terms of the economic use of antiprotons and consequently of PS protons; energy resolution; angular resolution; maximum reaction rate capability (statistical precision); efficient parasitic operation; transparency of the target for reaction products; access to low energies; and the ease of polarized target experiments. It is concluded that all p - experiments which need high statistics and high p - flux, such as studies of rare channels or broad, weak resonance structures, would profit from internal targets

  3. Overview of ion source characterization diagnostics in INTF

    Science.gov (United States)

    Bandyopadhyay, M.; Sudhir, Dass; Bhuyan, M.; Soni, J.; Tyagi, H.; Joshi, J.; Yadav, A.; Rotti, C.; Parmar, Deepak; Patel, H.; Pillai, S.; Chakraborty, A.

    2016-02-01

    INdian Test Facility (INTF) is envisaged to characterize ITER diagnostic neutral beam system and to establish the functionality of its eight inductively coupled RF plasma driver based negative hydrogen ion source and its beamline components. The beam quality mainly depends on the ion source performance and therefore, its diagnostics plays an important role for its safe and optimized operation. A number of diagnostics are planned in INTF to characterize the ion source performance. Negative ions and its cesium contents in the source will be monitored by optical emission spectroscopy (OES) and cavity ring down spectroscopy. Plasma near the extraction region will be studied using standard electrostatic probes. The beam divergence and negative ion stripping losses are planned to be measured using Doppler shift spectroscopy. During initial phase of ion beam characterization, carbon fiber composite based infrared imaging diagnostics will be used. Safe operation of the beam will be ensured by using standard thermocouples and electrical voltage-current measurement sensors. A novel concept, based on plasma density dependent plasma impedance measurement using RF electrical impedance matching parameters to characterize the RF driver plasma, will be tested in INTF and will be validated with OES data. The paper will discuss about the overview of the complete INTF diagnostics including its present status of procurement, experimentation, interface with mechanical systems in INTF, and integration with INTF data acquisition and control systems.

  4. Tribological diagnostics as a precondition for maintenance

    International Nuclear Information System (INIS)

    Jolevski, Tome

    1999-01-01

    The concept of maintenance in one industrial system usually represents a sum of constructions and rules that point out to several facts: 1) over which technical system the maintenance should be applied, 2) when it should be applied and 3) on which way it should be organized. In our real industrial systems the contemporary maintenance of the technical systems is not enough. Also, other contemporary measures whose basic task is to prevent unplanned stoppages as well as damages in the production process are insufficient. The equipment of the technical systems with devices for permanent monitoring of the condition, in other words with devices for technical diagnostic is unsatisfactorily, with a small exemption of the devices for vibration diagnostic monitoring of the condition in real time. The tribological diagnostics, using the procedures and methods without destroying as well as measuring and monitoring the condition of the lubrication devices, allows to find out the real status of the technical systems in operation. On that basic it is possible to undertake correct maintenance measures which would provide promising and safe operation of the technical systems. (Author)

  5. Role of simulator training in developing teamwork and diagnostic skills

    International Nuclear Information System (INIS)

    Grimme, W.E.

    1987-01-01

    A review of the evolution of the control room team is necessary to understand team training needs. As control room responsibilities have increased and members have been added to the operating crews, teamwork and strong leadership has become crucial to the efficiency of these operating crews. In order to conduct effective team training in a simulated control room, it is essential that the fundamental principles of role definition and common team values are fully developed. The diagnostics model used to develop problem-solving skills must be adaptable to the dynamic environment of the control room. Once the fundamental principles of team building and a good diagnostics model are mastered, many training techniques using a simulator are available to perfect the development of team building and diagnostic skills

  6. Beam diagnostic system for SSC on HIRFL central console

    International Nuclear Information System (INIS)

    Zhang Guixu; Wang Zhen; Huang Tuanhua

    1998-01-01

    The SSC ion beam diagnostic system on the console of HIRFL in institute of modern physics is presented. The information between console and diagnostic system can be transferred via DECnet communication. The central computer for HIRFL console is VAX-8350, the working computer of diagnostic system is changed from IBM PC/XT to COMPAQ 486, and the operating program is rewritten from FORTRAN to C. In order to communicate information, DECnet TTT function is put into both programs on the VAX and PC

  7. Diagnostics in Japan's microgravity experiments

    Science.gov (United States)

    Kadota, Toshikazu

    1995-01-01

    The achievement of the combustion research under microgravity depends substantially on the availability of diagnostic systems. The non-intrusive diagnostic systems are potentially applicable for providing the accurate, realistic and detailed information on momentum, mass and energy transport, complex gas phase chemistry, and phase change in the combustion field under microgravity. The non-intrusive nature of optical instruments is essential to the measurement of combustion process under microgravity which is very nervous to any perturbation. However, the implementation of the non-intrusive combustion diagnostic systems under microgravity is accompanied by several constraints. Usually, a very limited space is only available for constructing a highly sophisticated system which is so sensitive that it is easily affected by the magnitude of the gravitational force, vibration and heterogeneous field of temperature and density of the environments. The system should be properly adjusted prior to the experiment. Generally, it is quite difficult to tune the instruments during measurements. The programmed sequence of operation should also be provided. Extensive effort has been toward the development of non-intrusive diagnostic systems available for the combustion experiments under microgravity. This paper aims to describe the current art and the future strategy on the non-intrusive diagnostic systems potentially applicable to the combustion experiments under microgravity in Japan.

  8. Model-based Diagnostics for Propellant Loading Systems

    Data.gov (United States)

    National Aeronautics and Space Administration — The loading of spacecraft propellants is a complex, risky operation. Therefore, diagnostic solutions are neces- sary to quickly identify when a fault occurs, so that...

  9. Neutron Radiation Shielding For The NIF Streaked X-Ray Detector (SXD) Diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Song, P; Holder, J; Young, B; Kalantar, D; Eder, D; Kimbrough, J

    2006-11-02

    The National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL) is preparing for the National Ignition Campaign (NIC) scheduled in 2010. The NIC is comprised of several ''tuning'' physics subcampaigns leading up to a demonstration of Inertial Confinement Fusion (ICF) ignition. In some of these experiments, time-resolved x-ray imaging of the imploding capsule may be required to measure capsule trajectory (shock timing) or x-ray ''bang-time''. A capsule fueled with pure tritium (T) instead of a deutriun-tritium (DT) mixture is thought to offer useful physics surrogacy, with reduced yields of up to 5e14 neutrons. These measurements will require the use of the NIF streak x-ray detector (SXD). The resulting prompt neutron fluence at the planned SXD location ({approx}1.7 m from the target) would be {approx}1.4e9/cm{sup 2}. Previous measurements suggest the onset of significant background at a neutron fluence of {approx} 1e8/cm{sup 2}. The radiation damage and operational upsets which starts at {approx}1e8 rad-Si/sec must be factored into an integrated experimental campaign plan. Monte Carlo analyses were performed to predict the neutron and gamma/x-ray fluences and radiation doses for the proposed diagnostic configuration. A possible shielding configuration is proposed to mitigate radiation effects. The primary component of this shielding is an 80 cm thickness of Polyethylene (PE) between target chamber center (TCC) and the SXD diagnostic. Additionally, 6-8 cm of PE around the detector provide from the large number of neutrons that scatter off the inside of the target chamber. This proposed shielding configuration reduces the high-energy neutron fluence at the SXD by approximately a factor {approx}50.

  10. Neutron Radiation Shielding For The NIF Streaked X-Ray Detector (SXD) Diagnostic

    International Nuclear Information System (INIS)

    Song, P; Holder, J; Young, B; Kalantar, D; Eder, D; Kimbrough, J

    2006-01-01

    The National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL) is preparing for the National Ignition Campaign (NIC) scheduled in 2010. The NIC is comprised of several ''tuning'' physics subcampaigns leading up to a demonstration of Inertial Confinement Fusion (ICF) ignition. In some of these experiments, time-resolved x-ray imaging of the imploding capsule may be required to measure capsule trajectory (shock timing) or x-ray ''bang-time''. A capsule fueled with pure tritium (T) instead of a deutriun-tritium (DT) mixture is thought to offer useful physics surrogacy, with reduced yields of up to 5e14 neutrons. These measurements will require the use of the NIF streak x-ray detector (SXD). The resulting prompt neutron fluence at the planned SXD location (∼1.7 m from the target) would be ∼1.4e9/cm 2 . Previous measurements suggest the onset of significant background at a neutron fluence of ∼ 1e8/cm 2 . The radiation damage and operational upsets which starts at ∼1e8 rad-Si/sec must be factored into an integrated experimental campaign plan. Monte Carlo analyses were performed to predict the neutron and gamma/x-ray fluences and radiation doses for the proposed diagnostic configuration. A possible shielding configuration is proposed to mitigate radiation effects. The primary component of this shielding is an 80 cm thickness of Polyethylene (PE) between target chamber center (TCC) and the SXD diagnostic. Additionally, 6-8 cm of PE around the detector provide from the large number of neutrons that scatter off the inside of the target chamber. This proposed shielding configuration reduces the high-energy neutron fluence at the SXD by approximately a factor ∼50

  11. Diagnostic system for combine cycle power plant

    International Nuclear Information System (INIS)

    Shimizu, Yujiro; Nomura, Masumi; Tanaka, Satoshi; Ito, Ryoji; Kita, Yoshiyuki

    2000-01-01

    We developed the Diagnostic System for Combined Cycle Power Plant which enables inexperienced operators as well as experienced operators to cope with abnormal conditions of Combined Cycle Power Plant. The features of this system are the Estimate of Emergency Level for Operation and the Prediction of Subsequent Abnormality, adding to the Diagnosis of Cause and the Operation Guidance. Moreover in this system, Diagnosis of Cause was improved by using our original method and support screens can be displayed for educational means in normal condition as well. (Authors)

  12. Final design of the generic equatorial port plug structure for ITER diagnostic systems

    International Nuclear Information System (INIS)

    Udintsev, V.S.; Maquet, P.; Alexandrov, E.; Casal, N.; Cuenca, D.; Drevon, J.-M.; Feder, R.; Friconneau, J.P.; Giacomin, T.; Guirao, J.; Iglesias, S.; Josseaume, F.; Levesy, B.; Loesser, D.; Ordieres, J.; Quinn, E.; Pak, S.; Penot, C.; Pitcher, C.S.; Portalès, M.

    2015-01-01

    The Diagnostic Generic Equatorial Port Plug (GEPP) is designed to be common to all equatorial port-based diagnostic systems. It is designed to survive throughout the lifetime of ITER for 20 years, 30,000 discharges, and 3000 disruptions. The EPP structure dimensions (without Diagnostic First Walls and Diagnostic Shield Modules) are L2.9 × W1.9 × H2.4 m"3. The length of the fully integrated EPP is 3174 mm. The weight of the EPP structure is about 15 t, whereas the total weight of the integrated EPP may be up to 45 t. The EPP structure provides a flexible platform for a variety of diagnostics. The Diagnostic Shield Module assemblies, or drawers, allow a modular approach with respect to diagnostic integration and maintenance. In the nuclear phase of ITER operations, they will be remotely inserted into the EPP structure in the Hot Cell Facility. The port plug structure must also contribute to the nuclear shielding, or plugging, of the port and further contain circulated water to allow cooling during operation and heating during bake-out. The Final Design of the GEPP has been successfully passed in late 2013 and is now heading toward manufacturing. The final design of the GEPP includes interfaces, manufacturing, R&D, operation and maintenance, load cases and analysis of failure modes.

  13. X-ray imaging diagnostics for the inertial confinement fusion experiments

    International Nuclear Information System (INIS)

    Aglitskiy, Y.; Lehecka, T.; Obenschain, S.; Pawley, C.; Sethian, J.; Koch, J.A.; Holland, G.

    2000-01-01

    We report on our continued development of the advanced x-ray plasma diagnostics based on spherically curved crystals. The diagnostics include x-ray spectroscopy with 1-D spatial resolution, 2-D monochromatic self-imaging and back-lighting, and can be extended to the x-ray collimating and 2-D absorption and emission spectroscopy. The system is currently used, but not limited to the diagnostics of the targets ablatively accelerated by the NRL Nike KrF laser. In cooperation with LLNL a comprehensive test of the NIF prototype spherically curved crystal assembly has been performed on the Nova laser. (authors)

  14. X-ray imaging diagnostics for the inertial confinement fusion experiments

    Energy Technology Data Exchange (ETDEWEB)

    Aglitskiy, Y.; Lehecka, T. [Science Applications International Corp., McLean, VA (United States); Obenschain, S.; Pawley, C.; Sethian, J. [Naval Research Lab., Washington, DC (United States). Plasma Physics Div; Brown, C.M.; Seely, J. [Naval Research Lab., Space Sciences Div, Washington, DC (United States); Koch, J.A. [Lawrence Livermore National Lab., CA (United States); Holland, G. [SFA, Landover MD (United States)

    2000-07-01

    We report on our continued development of the advanced x-ray plasma diagnostics based on spherically curved crystals. The diagnostics include x-ray spectroscopy with 1-D spatial resolution, 2-D monochromatic self-imaging and back-lighting, and can be extended to the x-ray collimating and 2-D absorption and emission spectroscopy. The system is currently used, but not limited to the diagnostics of the targets ablatively accelerated by the NRL Nike KrF laser. In cooperation with LLNL a comprehensive test of the NIF prototype spherically curved crystal assembly has been performed on the Nova laser. (authors)

  15. Studies of a Target System for a 4-MW, 24-GeV Proton Beam

    CERN Multimedia

    2002-01-01

    We propose to perform a proof-of-principle test of a target station suitable for a Neutrino Factory or Muon Collider source using a 24-GeV proton beam incident on a target consisting of a free mercury jet that is inside a 15- T capture solenoid magnet. This test could be performed in the TT2A tunnel of the nTOF proton line (upstream of the spallation target). The tests would require only $\\approx$ 100 fast-extracted pulses of full PS intensity, delivered in a pulse-on-demand mode of operation over about 2 weeks. The main piece of apparatus is the LN2-precooled, 15- T copper magnet of total volume slightly over 1 m$^{3}$ with a 15-cm-diameter warm bore. The principle diagnostic is a high-speed optical camera. The mercury jet is part of a closed mercury loop that includes an insert into the bore of the magnet.

  16. Results of Scientific and Technical Supervision of Hydraulic Fracturing Operations

    Directory of Open Access Journals (Sweden)

    I.Kh. Makhmutov

    2017-11-01

    Full Text Available The paper presents actual results of the research conducted as part of a field pilot project which consisted in interpretation of minifrac test data and evaluation of the efficiency of the scientific and technical supervision of fracking operations. The research program involved 11 wells targeting Devonian terrigenous reservoirs. Minifrac tests in one perforation interval were performed only in seven wells, that is approximately in 64% of total well count. A reliable fracture closure estimate was obtained only in six wells (55%, beginning of pseudoradial flow was observed only in one well out of 11 wells (9%. Hence, conventional minifrac tests should be supplemented with other diagnostic injection tests. Analysis of the performance of hydraulic fracturing operations conducted according to this pilot project plan indicates that fracture modelling, and scientific and technical supervision of fracking operations performed by Hydrofrac Research Laboratory of Institute TatNIPIneft Tatneft PJSC have yielded beneficial effects, namely 1.44 times increase in oil production rates.

  17. Evaluating Utility in Diagnostic Decision Making.

    Science.gov (United States)

    Harber, Jean R.

    1981-01-01

    The utility of the procedures special educators apply in making decisions about the identification of handicapped individuals has not been thoroughly studied. The paper examines the utility of diagnostic decision making from the perspective of receiver operating curve analysis. (Author)

  18. Diagnostic application of Ga-67 scintigraphy in primary lung cancer, hepatoma and abdominal abscess. On surgical operation

    Energy Technology Data Exchange (ETDEWEB)

    Oshiumi, Yoshihiko (National Central Hospital of Fukuoka (Japan))

    1983-05-01

    It is difficult to detect tumor lesions by /sup 67/Ga-scintigraphy, though it is named as a tumor scintigraphy. Recently, /sup 67/Ga-scintigraphy is well used in the detection of inflammatic lesions. This paper is to discuss the detectability of lesions and diagnostic limitation on operability by /sup 67/Ga-scintigraphy to primary lung cancer, minute hepatoma and abdominal abscess. Primary lung cancer: In detecting metastatic hilar lymph nodes, the sensitivity is 54%, and the specificity is 78%. In detecting metastatic mediastinal lymph nodes, the sensitivity is 32% and the specificity is 89%. Minute hepatoma : The detectability depended on the size of the lesion. It is hard to detect lesions with under 2 cm by /sup 67/Ga-scintigraphy. Abdominal abscess : The sensitivity is 88%, and the specificity is 92%.

  19. Diagnostic imaging of craniopharyngioma

    International Nuclear Information System (INIS)

    Gradzki, J.; Nowak, S.; Paprzycki, W.

    1993-01-01

    40 patients have been examined with operational and histological confirmation of craniopharyngioma. CT image and X-ray plane of skull were performed in case all of these patients. TMR was conformed to examine 4 patients. X-ray planes was compared to CT. CT permits tumor cyst detection. The efficacy of mentioned above diagnostic techniques was compared with surgical findings. (author)

  20. Experimental Investigation on Admittance-Based Piezoelectric Sensor Diagnostic Process

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Hyejin; Park, Tongil; Park, Gyuhae [Chonnam National University, Gwangju (Korea, Republic of)

    2015-01-15

    Structural health monitoring (SHM) techniques based on the use of active-sensing piezoelectric (PZT) materials have received considerable attention. The validation of the PZT functionality during SHM operation is critical to successfully implementing a reliable SHM system. In this study, we investigated several parameters that affect the admittance-based sensor diagnostic process. We experimentally identified the temperature dependency of the active-sensor diagnostic process. We found that the admittance-based sensor diagnostic process can differentiate the adhesion conditions of bonding materials that are used to install a PZT on a structure, which is important when designing a sensor diagnostic process for an SHM system.

  1. uPAR as anti-cancer target

    DEFF Research Database (Denmark)

    Lund, Ida K; Illemann, Martin; Thurison, Tine

    2011-01-01

    , and a potential diagnostic and predictive impact of the different uPAR forms has been reported. Hence, pericellular proteolysis seems to be a suitable target for anti-cancer therapy and numerous approaches have been pursued. Targeting of this process may be achieved by preventing the binding of uPA to u...... using mouse monoclonal antibodies (mAbs) against mouse uPA or uPAR. These reagents will target uPA and uPAR in both stromal cells and cancer cells, and their therapeutic potential can now be assessed in syngenic mouse cancer models....

  2. Time-resolved x-ray diagnostics

    International Nuclear Information System (INIS)

    Lyons, P.B.

    1981-01-01

    Techniques for time-resolved x-ray diagnostics will be reviewed with emphasis on systems utilizing x-ray diodes or scintillators. System design concerns for high-bandwidth (> 1 GHz) diagnostics will be emphasized. The limitations of a coaxial cable system and a technique for equalizing to improve bandwidth of such a system will be reviewed. Characteristics of new multi-GHz amplifiers will be presented. An example of a complete operational system on the Los Alamos Helios laser will be presented which has a bandwidth near 3 GHz over 38 m of coax. The system includes the cable, an amplifier, an oscilloscope, and a digital camera readout

  3. Ignition analysis for burn control and diagnostic developments in ITER

    International Nuclear Information System (INIS)

    Mitarai, O.; Muraoka, K.

    1997-01-01

    The temporal evolutions of the operating point during the ignition access and ignited operation phases are analysed on the basis of zero dimensional (0-D) equations in order to clarify the requirements for safe control of ignited operation and for the development of diagnostic systems in ITER. A stable and safe method of reaching the ignited operating point is identified as the 'higher temperature access' method, being compatible with the H mode power threshold constraints. It is found that the ignition boundary can be experimentally determined by a 'thermonuclear oscillation' of the operating point without knowing the power balance equation. On the other hand, the ignition boundary determined by the power balance equation has a larger error bar depending on the accuracy of the diagnostic system. The plasma waveform response to sudden changes in the various plasma parameters during ignited operation is also calculated, and fusion power regulation is demonstrated by feedback control of the fuelling and auxiliary heating power. (author)

  4. Diagnostic x-ray equipment and its use

    International Nuclear Information System (INIS)

    1993-01-01

    The guide contains the requirements for the use, structure and operation of diagnostic x-ray equipment necessary to ensure the radiation safety of workers and patients. The guide is intended for the party responsible for operating the x-ray units, the staff operating, installing and maintaining x-ray examination equipment, and companies manufacturing and selling such equipment. Special requirements for mammographic and dental x-ray equipments are given in separate ST guides. (5 refs., 1 figs., 2 tabs.)

  5. Diagnostics and required R and D for control of DEMO grade plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hyeon K., E-mail: hyeonpark@unist.ac.kr [Fusion Plasma Stability and Confinement Research Center, UNIST, 50 Unist-gil, Ulju-gun, Ulsan (Korea, Republic of)

    2014-08-21

    Even if the diagnostics of ITER performs as expected, installation and operation of the diagnostic systems in Demo device will be much harsher than those of the present ITER device. In order to operate the Demo grade plasmas, which may have a higher beta limit, safely with very limited number of simple diagnostic system, it requires a well defined predictable plasma modelling in conjunction with the reliable control system for burn control and potential harmful instabilities. Development of such modelling in ITER is too risky and the logical choice would be utilization of the present day steady state capable devices such as KSTAR and EAST. In order to fulfill this mission, sophisticated diagnostic systems such as 2D/3D imaging systems can validate the physics in the theoretical modeling and challenge the predictable capability.

  6. Optimized acoustic biochip integrated with microfluidics for biomarkers detection in molecular diagnostics.

    Science.gov (United States)

    Papadakis, G; Friedt, J M; Eck, M; Rabus, D; Jobst, G; Gizeli, E

    2017-09-01

    The development of integrated platforms incorporating an acoustic device as the detection element requires addressing simultaneously several challenges of technological and scientific nature. The present work was focused on the design of a microfluidic module, which, combined with a dual or array type Love wave acoustic chip could be applied to biomedical applications and molecular diagnostics. Based on a systematic study we optimized the mechanics of the flow cell attachment and the sealing material so that fluidic interfacing/encapsulation would impose minimal losses to the acoustic wave. We have also investigated combinations of operating frequencies with waveguide materials and thicknesses for maximum sensitivity during the detection of protein and DNA biomarkers. Within our investigations neutravidin was used as a model protein biomarker and unpurified PCR amplified Salmonella DNA as the model genetic target. Our results clearly indicate the need for experimental verification of the optimum engineering and analytical parameters, in order to develop commercially viable systems for integrated analysis. The good reproducibility of the signal together with the ability of the array biochip to detect multiple samples hold promise for the future use of the integrated system in a Lab-on-a-Chip platform for application to molecular diagnostics.

  7. Development of a Diagnostic Complexity Questionnaire

    International Nuclear Information System (INIS)

    Collier, Steve

    1998-02-01

    The HRP human error analysis project has for some time been investigating what makes certain fault scenarios difficult for operators. One line of research has been to develop a questionnaire to measure diagnostic complexity. This report concerns some theoretical and experimental work underpinning the development of the questionnaire. A study of the literature reviewed the factors or components thought to contribute to difficulty in diagnosing and problem-solving. Two experimental studies of complexity were carried out using two versions of a questionnaire based on the review. The studies were simulator based, using scenarios designed to be diagnostically challenging. A factor-analytic approach to the analysis of the study data was suggested in the literature review. This is reported here (together with other analyses) though the factor analysis did not produce so clear results as was hoped. The present analysis found no clear factor structure with the first version of the complexity questionnaire used in experiment I. Partly because of this result, a factor-analytic approach to a second version of the questionnaire used in experiment II was not considered appropriate. A descriptive and qualitative analysis of the two questionnaire studies and a synthesis of the results from them both was promising. There were indications of components of complexity and some indications of what contributes to a personal perception of high or low diagnostic difficulty in fault scenarios. Components adding to diagnostic difficulty were tentatively named 'severity', 'need for co-operation', 'stress' and 'spread of changes'. Components not adding to difficulty were 'directness of indications', 'familiarity' and 'lack of stress'. There was some evidence of different responses to these components in a comparison of rule-based vs. knowledge-based diagnostic scenarios. These findings and experience with analysis techniques will feed into the design of further work on the human error

  8. Nuclear based diagnostics in high-power laser applications

    Energy Technology Data Exchange (ETDEWEB)

    Guenther, Marc; Sonnabend, Kerstin; Harres, Knut; Otten, Anke; Roth, Markus [TU Darmstadt, Institut fuer Kernphysik, Darmstadt (Germany); Vogt, Karsten; Bagnoud, Vincent [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany)

    2010-07-01

    High-power lasers allow focused intensities of >10{sup 18} W/cm{sup 2}. During the laser-solid interaction, an intense relativistic electron current is injected from the plasma into the target. One challenge is to characterize the electron dynamic close to the interaction region. Moreover, next generation high-power laser proton acceleration leads to high proton fluxes, which require novel, nuclear diagnostic techniques. We present an activation-based nuclear pyrometry for the investigation of electrons generated in relativistic laser-solid interactions. We use novel activation targets consisting of several isotopes with different photo-neutron disintegration thresholds. The electrons are decelerated inside the target via bremsstrahlung processes. The high-energy bremsstrahlung induces photo-nuclear reactions. In this energy range no disturbing low energy effects are important. Via the pyrometry the Reconstruction of the absolute yield, spectral and spatial distribution of the electrons is possible. For the characterization of proton beams we present a nuclear activation imaging spectroscopy (NAIS). The diagnostic is based on proton-neutron disintegration reactions of copper stacked in consecutive layers. An autoradiography of copper layers leads to spectrally and spatially reconstruction of the beam profile.

  9. Diagnostic efficacy of radiological examinations in clefts of the hard palate; Skutecznosc diagnostyczna badan rentgenowskich w rozszczepach podniebienia twardego

    Energy Technology Data Exchange (ETDEWEB)

    Cieslinska-Wilk, G. [Pomorska Akademia Medyczna, Szczecin (Poland)

    1992-12-31

    The aim of the work has been: (1) evaluating the efficiency of individual radiological methods in visualizing the bone structure of the hard palate; (2) elaboration of a method for skull examination, by means of which the hard palate region in patients would be best visible; (3) presentation of radiological symptomatology of hard palate clefts; (4) establishing algorithms of diagnostic procedure and determining the type of radiological examination most helpful in planning the treatment of this anomaly. Selected problems from normal anatomy of the hard palate are presented, and the technique of radiological examination in the form of occlusal radiograms, pantomography and computerized tomography (CT) are discussed. Clinical material encompassed the total of 312 patients. A total of 470 radiograms were performed, 150 occlusal ones of hard palate, 200 pantomograms (jointly with the control group) as well as 120 scannings during CT examination. It has been stated the greatest efficiency and effectiveness in planning the treatment are ascribed to computerized tomography, the second place goes to pantomography, on the third position are occlusal radiograms targeted at the region of the cleft. Algorithms have been provided for roentgen-diagnostic procedure in cases of the hard palate clefts, with an emphasis that the very first examination of a child should include the occlusal radiograms targeted at the cleft region and pantomogram; in the course of conservative treatment only pantomogram is proposed to be made, and in case of planned operative procedure - CT examination. For evaluating the calcification of the cleft, the best and with the least irradiation are the intraoral occlusal radiograms, targeted at the region of the cleft, performed 12 months after the operation. (author). 100 refs, 21 figs, 12 tabs.

  10. A gas turbine diagnostic approach with transient measurements.

    OpenAIRE

    Li, Y. G.

    2003-01-01

    Most gas turbine performance analysis based diagnostic methods use the information from steady state measurements. Unfortunately, steady state measurement may not be obtained easily in some situations, and some types of gas turbine fault contribute little to performance deviation at steady state operating conditions but significantly during transient processes. Therefore, gas turbine diagnostics with transient measurement is superior to that with steady state measurement. In this paper, an ac...

  11. Comparative guide to emerging diagnostic tools for large commercial HVAC systems; TOPICAL

    International Nuclear Information System (INIS)

    Friedman, Hannah; Piette, Mary Ann

    2001-01-01

    This guide compares emerging diagnostic software tools that aid detection and diagnosis of operational problems for large HVAC systems. We have evaluated six tools for use with energy management control system (EMCS) or other monitoring data. The diagnostic tools summarize relevant performance metrics, display plots for manual analysis, and perform automated diagnostic procedures. Our comparative analysis presents nine summary tables with supporting explanatory text and includes sample diagnostic screens for each tool

  12. Nuclear Diagnostics at the National Ignition Facility, 2013-2015

    Science.gov (United States)

    Yeamans, C. B.; Cassata, W. S.; Church, J. A.; Fittinghoff, D. N.; Gatu Johnson, M.; Gharibyan, N.; Határik, R.; Sayre, D. B.; Sio, H. W.; Bionta, R. M.; Bleuel, D. L.; Caggiano, J. A.; Cerjan, C. J.; Cooper, G. W.; Eckart, M. J.; Edwards, E. R.; Faye, S. A.; Forrest, C. J.; Frenje, J. A.; Glebov, V. Yu; Grant, P. M.; Grim, G. P.; Hartouni, E. P.; Herrmann, H. W.; Kilkenny, J. D.; Knauer, J. P.; Mackinnon, A. J.; Merrill, F. E.; Moody, K. J.; Moran, M. J.; Petrasso, R. D.; Phillips, T. W.; Rinderknecht, H. G.; Schneider, D. H. G.; Sepke, S. M.; Shaughnessy, D. A.; Stoeffl, W.; Velsko, C. A.; Volegov, P.

    2016-05-01

    The National Ignition Facility (NIF) relies on a suite of nuclear diagnostics to measure the neutronic output of experiments. Neutron time-of-flight (NTOF) and neutron activation diagnostics (NAD) provide performance metrics of absolute neutron yield and neutron spectral content: spectral width and non-thermal content, from which implosion physical quantities of temperature and scattering mass are inferred. Spatially-distributed flange- mounted NADs (FNAD) measure, with nearly identical systematic uncertainties, primary DT neutron emission to infer a whole-sky neutron field. An automated FNAD system is being developed. A magnetic recoil spectrometer (MRS) shares few systematics with comparable NTOF and NAD devices, and as such is deployed for independent measurement of the primary neutronic quantities. The gas-Cherenkov Gamma Reaction History (GRH) instrument records four energy channels of time-resolved gamma emission to measure nuclear bang time and burn width, as well as to infer carbon areal density in experiments utilizing plastic or diamond capsules. A neutron imaging system (NIS) takes two images of the neutron source, typically gated to create coregistered 13-15 MeV primary and 6-12 MeV downscattered images. The radiochemical analysis of gaseous samples (RAGS) instrument pumps target chamber gas to a chemical reaction and fractionation system configured with gamma counters, allowing measurement of radionuclides with half-lives as short as 8 seconds. Solid radiochemistry collectors (SRC) with backing NAD foils collect target debris, where activated materials from the target assembly are used as indicators of neutron spectrum content, and also serve as the primary diagnostic for nuclear forensic science experiments. Particle time-of-flight (PTOF) measures compression-bang time using DT- or DD-neutrons, as well as shock bang-time using D3He-protons for implosions with lower x-ray background. In concert, these diagnostics serve to measure the basic and advanced

  13. Plasma diagnostics in compact torus of UNICAMP (Campinas state university)

    International Nuclear Information System (INIS)

    Ueda, M; Doi, Y.; Aramaki, E.A.; Porto, P.; Berni, L.; Machida, M.

    1989-08-01

    This paper which describes experiments carried out in the Compact Torus of UNICAMP (TC-1) is divided into 3 parts: 1) summary of TC-1 characteristics and its operation mode; 2) description of diagnostics in use and ones to be installed, 3) recent experimental results using optical and electromagnetical diagnostics. (author)

  14. Report on the diagnostics for control of the fusion DEMO reactors

    International Nuclear Information System (INIS)

    2014-05-01

    The range of diagnostics that can be used in DEMO will be severely restricted compared to that used in the current experiments or to be used in ITER. Therefore, a study is planned on the technical feasibility of sensors and diagnostics on the basis of specific tokamak and helical DEMO designs, with the involvement of a wide range of specialists covering reactor design, diagnostics, neutronics, reactor structure, remote maintenance, plasma physics, plasma and machine control, and computer simulation. Topics included typical characteristic times of target plasma behavior, diagnostics tools with their resolution and lifetime, response time of actuators, and plasmas. Through these studies, possible candidates for DEMO diagnostics were identified. The outcome of two years of activities is summarized in this report with a recommendation to the government of Japan. (J.P.N.)

  15. The future of targeted peptidomics.

    Science.gov (United States)

    Findeisen, Peter

    2013-12-01

    Targeted MS is becoming increasingly important for sensitive and specific quantitative detection of proteins and respective PTMs. In this article, Ceglarek et al. [Proteomics Clin. Appl. 2013, 7, 794-801] present an LC-MS-based method for simultaneous quantitation of seven apolipoproteins in serum specimens. The assay fulfills many necessities of routine diagnostic applications, namely, low cost, high throughput, and good reproducibility. We anticipate that validation of new biomarkers will speed up with this technology and the palette of laboratory-based diagnostic tools will hopefully be augmented significantly in the near future. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Diagnostic reasoning strategies and diagnostic success.

    Science.gov (United States)

    Coderre, S; Mandin, H; Harasym, P H; Fick, G H

    2003-08-01

    Cognitive psychology research supports the notion that experts use mental frameworks or "schemes", both to organize knowledge in memory and to solve clinical problems. The central purpose of this study was to determine the relationship between problem-solving strategies and the likelihood of diagnostic success. Think-aloud protocols were collected to determine the diagnostic reasoning used by experts and non-experts when attempting to diagnose clinical presentations in gastroenterology. Using logistic regression analysis, the study found that there is a relationship between diagnostic reasoning strategy and the likelihood of diagnostic success. Compared to hypothetico-deductive reasoning, the odds of diagnostic success were significantly greater when subjects used the diagnostic strategies of pattern recognition and scheme-inductive reasoning. Two other factors emerged as independent determinants of diagnostic success: expertise and clinical presentation. Not surprisingly, experts outperformed novices, while the content area of the clinical cases in each of the four clinical presentations demonstrated varying degrees of difficulty and thus diagnostic success. These findings have significant implications for medical educators. It supports the introduction of "schemes" as a means of enhancing memory organization and improving diagnostic success.

  17. DIAGNOSTIC OF CNC LATHE WITH QC 20 BALLBAR SYSTEM

    Directory of Open Access Journals (Sweden)

    Jerzy Józwik

    2015-11-01

    Full Text Available This paper presents the evaluation of the influence of the feedmotion speed on the value of selected geometric errors of CNC lathe CTX 310 eco by DMG, indentified by QC 20 Ballbar system. Diagnostically evaluated were: the deviation of the axis squareness, reversal spike, and backlash. These errors determine the forming of the dimensional and shape accuracy of a machine tool. The article discusses the process of the CNC diagnostic test, the diagnostic evaluation and formulates guidelines on further CNC operation. The results of measurements were presented in tables and diagrams.

  18. Diagnostic accuracy of touch imprint cytology for head and neck malignancies: a useful intra-operative tool in resource limited countries.

    Science.gov (United States)

    Naveed, Hania; Abid, Mariam; Hashmi, Atif Ali; Edhi, Muhammad Muzammamil; Sheikh, Ahmareen Khalid; Mudassir, Ghazala; Khan, Amir

    2017-01-01

    Intraoperative consultation is an important tool for the evaluation of the upper aerodigestive tract (UAT) malignancies. Although frozen section analysis is a preferred method of intra-operative consultation, however in resource limited countries like Pakistan, this facility is not available in most institutes; therefore, we aimed to evaluate the diagnostic accuracy of touch imprint cytology for UAT malignancies using histopathology of the same tissue as gold standard. The study involved 70 cases of UAT lesions operated during the study period. Intraoperatively, after obtaining the fresh biopsy specimen and prior to placing them in fixative, each specimen was imprinted on 4-6 glass slides, fixed immediately in 95% alcohol and stained with Hematoxylin and Eosin stain. After completion of the cytological procedure, the surgical biopsy specimen was processed. The slides of both touch Imprint cytology and histopathology were examined by two consultant histopathologists. The result of touch imprint cytology showed that touch imprint cytology was diagnostic in 68 cases (97.1%), 55 (78.6%) being malignant, 2 cases (2.9%) were suspicious for malignancy, 11 cases (15.7%) were negative for malignancy while 2 cases (2.9%) were false negative. Amongst the 70 cases, 55 cases (78.6%) were malignant showing squamous cell carcinoma in 49 cases (70%), adenoid cystic carcinoma in 2 cases (2.9%), non-Hodgkin lymphoma 2 cases (2.9%), Mucoepidermoid carcinoma 1 case (1.4%), spindle cell sarcoma in 1 case (1.4%). Two cases (2.9%) were suspicious of malignancy showing atypical squamoid cells on touch imprint cytology, while 13 cases (18.6%) were negative for malignancy, which also included 2 false negative cases. The overall diagnostic accuracy of touch imprint cytology came out to be 96.7% with a sensitivity and specificity of 96 and 100%, respectively while PPV and NPV of touch imprint cytology was found to be 100 and 84%, respectively. Our experience in this study has demonstrated

  19. Comparative Evaluation of the Diagnostic Performance of the Prototype Cepheid GeneXpert Ebola Assay

    Science.gov (United States)

    Jansen van Vuren, Petrus; Grobbelaar, Antoinette; Storm, Nadia; Conteh, Ousman; Konneh, Kelfala; Kamara, Abdul; Sanne, Ian

    2015-01-01

    The Ebola virus disease (EVD) outbreak in West Africa has highlighted an urgent need for point-of-care (POC) assays for the diagnosis of this devastating disease in resource-limited African countries. The diagnostic performance characteristics of a prototype Cepheid GeneXpert Ebola POC used to detect Ebola virus (EBOV) in stored serum and plasma samples collected from suspected EVD cases in Sierra Leone in 2014 and 2015 was evaluated. The GeneXpert Ebola POC is a self-contained single-cartridge automated system that targets the glycoprotein (GP) and nucleoprotein (NP) genes of EBOV and yields results within 90 min. Results from 281 patient samples were compared to the results of a TaqMan real-time reverse transcription-PCR (RT-PCR) targeting the polymerase gene and performed on two real-time PCR machines. Agreement between the three platforms was 100% at cycle threshold (CT) values of ≤34.99, but discordant results were noted between CT values of 35 and 45.The diagnostic sensitivity of the three platforms was 100% in 91 patient samples that were confirmed to be infectious by virus isolation. All three molecular platforms detected viral EBOV RNA in additional samples that did not contain viable EBOV. The analytical sensitivity of the GeneXpert Ebola POC for the detection of NP was higher, and comparable to that of polymerase gene detection, than that for the detection of GP when using a titrated laboratory stock of EBOV. There was no detectable cross-reactivity with other hemorrhagic fever viruses or arboviruses. The GeneXpert Ebola POC offers an easy to operate and sensitive diagnostic tool that can be used for the rapid screening of suspected EVD cases in treatment or in holding centers during EVD outbreaks. PMID:26637383

  20. 14th Biennial conference on reactor operating experience plant operations: The human element

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    Separate abstracts were prepared for the papers presented in the following areas of interest: enhancing operator performance; structured approaches to maintenance standards and reliability-centered maintenance; human issues in plant operations and management; test, research, and training reactor utilization; methods and applications of root-cause analysis; emergency operating procedure enhancement programs; test, research, and training reactor upgrades; valve maintenance and diagnostics; recent operating experiences; and current maintenance issues

  1. Equipment for isotope diagnostics

    International Nuclear Information System (INIS)

    Platz, W.

    1976-01-01

    The invention concerns an improvement of equipment for isotope diagnostics allowing to mark special intensity ranges of the recorded measurements by means of different colors. For undisturbed operation it is of advantage to avoid electric circuits between movable and unmovable parts of the color recorder. According to the invention, long gear wheels of glass fiber-reinforced polyamide are used for these connections. (ORU) [de

  2. Screening of potential diagnostic markers and therapeutic targets against colorectal cancer

    Directory of Open Access Journals (Sweden)

    Tian XQ

    2015-07-01

    Full Text Available XiaoQing Tian, DanFeng Sun, ShuLiang Zhao, Hua Xiong, JingYuan Fang Department of Gastroenterology and Hepatology, Renji Hospital, School of Medicine, Shanghai Institute of Digestive Disease, Shanghai Jiao Tong University, Shanghai, People’s Republic of China Objective: To identify genes with aberrant promoter methylation for developing novel diagnostic markers and therapeutic targets against primary colorectal cancer (CRC. Methods: Two paired CRC and adjacent normal tissues were collected from two CRC patients. A Resi: MBD2b protein-sepharose-4B column was used to enrich the methylated DNA fragments. Difference in the average methylation level of each DNA methylation region between the tumor and control samples was determined by log2 fold change (FC in each patient to screen the differentially methylated DNA regions. Genes with log2FC value ≥4 or ≤-4 were identified to be hypermethylated and hypomethylated, respectively. Then, the underlying functions of methylated genes were speculated by Gene Ontology database and pathway enrichment analyses. Furthermore, a protein–protein interaction network was built using Search Tool for the Retrieval of Interacting Genes/Proteins database, and the transcription factor binding sites were screened via the Encyclopedia of DNA Elements (ENCODE database. Results: Totally, 2,284 and 1,142 genes were predicted to have aberrant promoter hypermethylation or hypomethylation, respectively. MAP3K5, MAP3K8, MAPK14, and MAPK9 with promoter hypermethylation functioned via MAPK signaling pathway, focal adhesion, or Wnt signaling pathway, whereas MAP2K1, MAPK3, MAPK11, and MAPK7 with promoter hypomethylation functioned via TGF-beta signaling pathway, neurotrophin signaling pathway, and chemokine signaling pathway. CREBBP, PIK3R1, MAPK14, APP, ESR1, MAPK3, and HRAS were the seven hubs in the constructed protein–protein interaction network. RPL22, RPL36, RPLP2, RPS7, and RPS9 were commonly regulated by

  3. Guide to good practices for teamwork training and diagnostic skills development

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-06-01

    This guide provides assistance in the development, implementation, and improvement of training on teamwork and diagnostics. DOE and contractor representatives identified the need for teamwork and diagnostics training guidance. This need was based on the increasing emphasis of properly applying knowledge and skills to complete assigned tasks. Teamwork and diagnostic skills have become a focal point because of the impact they have on effective facility operation and safety.

  4. Recent progress in nanomedicine: therapeutic, diagnostic and theranostic applications

    NARCIS (Netherlands)

    Rizzo, L.Y.; Theek, B.; Storm, Gerrit; Kiessling, F.; Lammers, Twan Gerardus Gertudis Maria

    2013-01-01

    In recent years, the use of nanomedicine formulations for therapeutic and diagnostic applications has increased exponentially. Many different systems and strategies have been developed for drug targeting to pathological sites, as well as for visualizing and quantifying important (patho-)

  5. Prioritic directions of inculcation of diagnostic equipment at NPP

    International Nuclear Information System (INIS)

    Morozov, V.I.

    2000-01-01

    The diagnostic provision creates the conditions for increasing the safety and reliability of the NPP functioning, technical service and maintenance by the actual state. With an account of the large number of the NPP equipment elements, limitedness of financial resources, different technical-economical effect from diagnostics determination of the priority directions for introduction of technical diagnostic means into the operational practice is one of the main factors. The method for determining the above-mentioned priorities is proposed. The main aspects of the method and mathematical models, based on the logical-probabilistic modeling, are presented. The essence of the method consists in ranging the technical-economical effect from introduction of various factors of the diagnostic equipment [ru

  6. Optical beam diagnostics on PEP

    International Nuclear Information System (INIS)

    Sabersky, A.P.

    1981-02-01

    In designing the PEP optical diagnostics we have been able to build on the experience gained with SPEAR. Most of the problems at SPEAR could be traced to the optical diagnostic system being inside the tunnel. A machine shutdown is required for any maintenance or modification. This implies that in order to make such an instrument successful, a large engineering effort must be mounted to ensure 100% operation at startup. The functions that do not work at startup may never be made to work; this has happened at several machines. Experimental setups are likewise risky and time consuming. A point which has been borne out in both SPEAR and PEP is that the mechanical part of the instrument, the special vacuum chamber, the optical mounts, the alignment and adjustments, require approximately 60% of the effort and cost of the optical diagnostics. It is far better to economize on detectors and electronics than on mechanical and optical essentials

  7. Static and dynamic scintigraphy in radioisotope cardiology diagnostics

    International Nuclear Information System (INIS)

    Waligorski, M.; Zolna, J.; Strzelecki, A.; Pasyk, S.

    1981-01-01

    A review of the applications of scintigraphy in cardiac diagnosis is given. The principle of operation of the gamma-camera and of the scintigraphic system, the handling of data and the so-called gated scintigraphy are discussed. Characteristics of some radioisotopes applied in nuclear cardiology are given. The most frequent clinical states are discussed in which isotope diagnostics may be useful. Attention is drawn to the advantages of nuclear cardiology methods over conventional diagnostics. (author)

  8. Aircraft gas turbine engine vibration diagnostics

    Directory of Open Access Journals (Sweden)

    Stanislav Fábry

    2017-11-01

    Full Text Available In the Czech and Slovak aviation are in service elderly aircrafts, usually produced in former Soviet Union. Their power units can be operated in more efficient way, in case of using additional diagnostic methods that allow evaluating their health. Vibration diagnostics is one of the methods indicating changes of rotational machine dynamics. Ground tests of aircraft gas turbine engines allow vibration recording and analysis. Results contribute to airworthiness evaluation and making corrections, if needed. Vibration sensors distribution, signal recording and processing are introduced in a paper. Recorded and re-calculated vibration parameters are used in role of health indicators.

  9. Charcot-Marie-Tooth disease: The development of a diagnostic platform using next generation sequencing

    DEFF Research Database (Denmark)

    Christensen, Rikke; Væth, Signe; Thorsen, Kasper

    , Sanger sequencing of 4 genes have led to a diagnosis in approximately 30% of the patients. Aims: 1) Development of a targeted NGS platform containing 63 genes that currently are found to be associated with CMT. 2) Analysis of the increased diagnostic yield using this platform to analyze 200 CMT samples...... previously analyzed using Sanger sequencing without identification of a disease causing mutation. Materials and Methods: Libraries for 200 patient samples obtained for CMT diagnostics were prepared using Illumina Truseq and target enrichment using SeqCap EZ Choise Library (Nimblegen). The libraries were...

  10. Calibration issues for neutron diagnostics

    International Nuclear Information System (INIS)

    Sadler, G.J.; Adams, J.M.; Barnes, C.W.

    1997-01-01

    The performance of diagnostic systems are limited by their weakest constituents, including their calibration issues. Neutron diagnostics are notorious for problems encountered while determining their absolute calibrations, due mainly to the nature of the neutron transport problem. In order to facilitate the determination of an accurate and precise calibration, the diagnostic design should be such as to minimize the scattered neutron flux. ITER will use a comprehensive set of neutron diagnostics--comprising radial and vertical neutron cameras, neutron spectrometers, a neutron activation system and internal and external fission chambers--to provide accurate measurements of fusion power and power densities as a function of time. The calibration of such an important diagnostic system merits careful consideration. Some thoughts have already been given to this subject during the conceptual design phase in relation to the time-integrated neutron activation and time-dependent neutron yield monitors. However, no overall calibration strategy has been worked out so far. This paper represents a first attempt to address this vital issue. Experience gained from present large tokamaks (JET, TFTR and JT60U) and proposals for ITER are reviewed. The need to use a 14-MeV neutron generator as opposed to radioactive sources for in-situ calibration of D-T diagnostics will be stressed. It is clear that the overall absolute determination of fusion power will have to rely on a combination of nuclear measuring techniques, for which the provision of accurate and independent calibrations will constitute an ongoing process as ITER moves from one phase of operation to the next

  11. Realization of process improvement at a diagnostic radiology department with aid of simulation modeling.

    Science.gov (United States)

    Oh, Hong-Choon; Toh, Hong-Guan; Giap Cheong, Eddy Seng

    2011-11-01

    Using the classical process improvement framework of Plan-Do-Study-Act (PDSA), the diagnostic radiology department of a tertiary hospital identified several patient cycle time reduction strategies. Experimentation of these strategies (which included procurement of new machines, hiring of new staff, redesign of queue system, etc.) through pilot scale implementation was impractical because it might incur substantial expenditure or be operationally disruptive. With this in mind, simulation modeling was used to test these strategies via performance of "what if" analyses. Using the output generated by the simulation model, the team was able to identify a cost-free cycle time reduction strategy, which subsequently led to a reduction of patient cycle time and achievement of a management-defined performance target. As healthcare professionals work continually to improve healthcare operational efficiency in response to rising healthcare costs and patient expectation, simulation modeling offers an effective scientific framework that can complement established process improvement framework like PDSA to realize healthcare process enhancement. © 2011 National Association for Healthcare Quality.

  12. Modification of the Integrated Sasang Constitutional Diagnostic Model

    Directory of Open Access Journals (Sweden)

    Jiho Nam

    2017-01-01

    Full Text Available In 2012, the Korea Institute of Oriental Medicine proposed an objective and comprehensive physical diagnostic model to address quantification problems in the existing Sasang constitutional diagnostic method. However, certain issues have been raised regarding a revision of the proposed diagnostic model. In this paper, we propose various methodological approaches to address the problems of the previous diagnostic model. Firstly, more useful variables are selected in each component. Secondly, the least absolute shrinkage and selection operator is used to reduce multicollinearity without the modification of explanatory variables. Thirdly, proportions of SC types and age are considered to construct individual diagnostic models and classify the training set and the test set for reflecting the characteristics of the entire dataset. Finally, an integrated model is constructed with explanatory variables of individual diagnosis models. The proposed integrated diagnostic model significantly improves the sensitivities for both the male SY type (36.4% → 62.0% and the female SE type (43.7% → 64.5%, which were areas of limitation of the previous integrated diagnostic model. The ideas of these new algorithms are expected to contribute not only to the scientific development of Sasang constitutional medicine in Korea but also to that of other diagnostic methods for traditional medicine.

  13. Conserved B-cell epitopes among human bocavirus species indicate potential diagnostic targets.

    Directory of Open Access Journals (Sweden)

    Zhuo Zhou

    Full Text Available BACKGROUND: Human bocavirus species 1-4 (HBoV1-4 have been associated with respiratory and enteric infections in children. However, the immunological mechanisms in response to HBoV infections are not fully understood. Though previous studies have shown cross-reactivities between HBoV species, the epitopes responsible for this phenomenon remain unknown. In this study, we used genomic and immunologic approaches to identify the reactive epitopes conserved across multiple HBoV species and explored their potential as the basis of a novel diagnostic test for HBoVs. METHODOLOGY/PRINCIPAL FINDINGS: We generated HBoV1-3 VP2 gene fragment phage display libraries (GFPDLs and used these libraries to analyze mouse antisera against VP2 protein of HBoV1, 2, and 3, and human sera positive for HBoVs. Using this approach, we mapped four epitope clusters of HBoVs and identified two immunodominant peptides--P1 (¹MSDTDIQDQQPDTVDAPQNT²⁰, and P2 (¹⁶²EHAYPNASHPWDEDVMPDL¹⁸⁰--that are conserved among HBoV1-4. To confirm epitope immunogenicity, we immunized mice with the immunodominant P1 and P2 peptides identified in our screen and found that they elicited high titer antibodies in mice. These two antibodies could only recognize the VP2 of HBoV 1-4 in Western blot assays, rather than those of the two other parvoviruses human parvovirus B19 and human parvovirus 4 (PARV4. Based on our findings, we evaluated epitope-based peptide-IgM ELISAs as potential diagnostic tools for HBoVs IgM antibodies. We found that the P1+P2-IgM ELISA showed a higher sensitivity and specificity in HBoVs IgM detection than the assays using a single peptide. CONCLUSIONS/SIGNIFICANCE: The identification of the conserved B-cell epitopes among human bocavirus species contributes to our understanding of immunological cross-reactivities of HBoVs, and provides important insights for the development of HBoV diagnostic tools.

  14. Methodology of diagnostic tests in hepatology

    DEFF Research Database (Denmark)

    Christensen, Erik

    2009-01-01

    The performance of diagnostic tests can be assessed by a number of methods. These include sensitivity, specificity,positive and negative predictive values, likelihood ratios and receiver operating characteristic (ROC) curves. This paper describes the methods and explains which information...... they provide. Sensitivity and specificity provides measures of the diagnostic accuracy of a test in diagnosing the condition. The positive and negative predictive values estimate the probability of the condition from the test-outcome and the condition's prevalence. The likelihood ratios bring together......' and plotting sensitivity as a function of 1-specificity. The ROC-curve can be used to define optimal cut-off values for a test, to assess the diagnostic accuracy of the test, and to compare the usefulness of different tests in the same patients. Under certain conditions it may be possible to utilize a test...

  15. Remote operation and maintenance support services for nuclear power plants

    International Nuclear Information System (INIS)

    Yamamoto, Hiroki; Higuma, Koji; Shimizu, Shunichi; Sakuma, Masatake; Sonoda, Yukio; Kanemoto, Shigeru

    2004-01-01

    Toshiba Corporation constructed e-Toshiba Operating Plant Service (e-TOPS TM ) system and began remote operation and maintenance support service for nuclear power plants. The service put into practice remote operation and maintenance by harmony of information technologies such as internet and mobile, and nuclear power measurement/diagnostic technologies and security techniques. Outline of e-TOPS TM , remote-control service, -inspection system, -diagnostic service and technologies support service are explained. Construction, objects and application effects of e-TOPS TM , remote diagnostic system using image treatment techniques, construction of device record card control system are illustrated. (S.Y.)

  16. Development of gyrotrons for plasma diagnostics (invited)

    International Nuclear Information System (INIS)

    Woskoboinikow, P.

    1986-01-01

    Recent advances in high-frequency (>100 GHz) gyrotron technology are reviewed and application to millimeter/submillimeter wave plasma diagnostics is discussed. Gyrotrons have useful capabilities of high-power (>1 kW), long pulse/cw operation, narrow linewidth (<100 kHz), and good spatial mode quality with efficient (--90%) mode converters. These capabilities could be used to significantly improve collective Thomson scattering diagnostics for the study of instabilities, plasma waves, turbulence, and thermal ion fluctuations. Imaging applications with many detector arrays of plasma density, field direction, and microinstabilities may be possible with gyrotons. In a high-field compact ignition tokamak experiment a possible millimeter wave diagnostics window could be exploited by a gyrotron to measure a number of parameters, including alpha particle density and velocity distribution

  17. Status of the SLAC SNOOP diagnostic module for FASTBUS

    International Nuclear Information System (INIS)

    Walz, H.V.; Gustavson, D.B.

    1983-03-01

    A SNOOP Diagnostic Module for FASTBUS is under development at SLAC. The SNOOP Module resides on a FASTBUS crate segment and provides diagnostic monitoring and testing capability. It consists of a high-speed ECL front-end to monitor and single-step segment operations, a simple master interface, and a control processor with two serial communication ports. Module features and specifications are summrized, and prototype hardware is shown

  18. Diagnostics Beamline for the SRF Gun Project

    CERN Document Server

    Kamps, T; Goldammer, K; Krämer, Dietrich; Kuske, P; Kuszynski, J; Lipka, D; Marhauser, F; Quast, T; Richter, R

    2005-01-01

    A superconducting rf photo electron injector (SRF gun) is currently under construction by a collaboration between BESSY, DESY, FZR and MBI. The project aims at the design and setup of an CW SRF gun including a diagnostics beamline for the ELBE FEL and to address R&D issues on low emittance injectors for future light sources such as the BESSY FEL. Of critical importance for the injector performance is the control of the electron beam parameters. For this reason a compact diagnostics beamline is under development serving a multitude of operation settings ranging from low-charge (77pC), low-emittance (1 pi mm mrad) mode to high-charge (2.5nC) operation of the gun. For these operation modes beam dynamics simulations are resulting in boundary conditions for the beam instrumentation. Proven and mature technology is projected wherever possible, for example for current and beam position monitoring. The layout of the beam profile and emittance measurement systems is described. For the bunch length, which varies be...

  19. Dynamic Visualization of SNS Diagnostics Summary Report and System Status

    CERN Document Server

    Blokland, Willem; Long, Cary D; Murphy, Darryl J; Purcell, John D; Sundaram, Madhan

    2005-01-01

    The Spallation Neutron Source (SNS) accelerator systems will deliver a 1.0 GeV, 1.4 MW proton beam to a liquid mercury target for neutron scattering research. The accelerator complex consists of a 1 GeV linear accelerator, an accumulator ring and associated transport lines. The SNS diagnostics platform is PC-based running Embedded Windows XP and LabVIEW. The diagnostics instruments communicate with the control system using the Channel Access (CA) protocol of the Experimental Physics and Industrial Control System (EPICS). This paper describes the Diagnostics Group's approach to collecting data from the instruments, processing it, and presenting live in a summarized way over the web. Effectively, adding a supervisory level to the diagnostics instruments. One application of this data mining is the "Diagnostics Status Page" that summarizes the insert-able devices, transport efficiencies, and the mode of the accelerator in a compact webpage. The displays on the webpage change automatically to show the latest and/o...

  20. Multi-method automated diagnostics of rotating machines

    Science.gov (United States)

    Kostyukov, A. V.; Boychenko, S. N.; Shchelkanov, A. V.; Burda, E. A.

    2017-08-01

    The automated machinery diagnostics and monitoring systems utilized within the petrochemical plants are an integral part of the measures taken to ensure safety and, as a consequence, the efficiency of these industrial facilities. Such systems are often limited in their functionality due to the specifics of the diagnostic techniques adopted. As the diagnostic techniques applied in each system are limited, and machinery defects can have different physical nature, it becomes necessary to combine several diagnostics and monitoring systems to control various machinery components. Such an approach is inconvenient, since it requires additional measures to bring the diagnostic results in a single view of the technical condition of production assets. In this case, we mean by a production facility a bonded complex of a process unit, a drive, a power source and lines. A failure of any of these components will cause an outage of the production asset, which is unacceptable. The purpose of the study is to test a combined use of vibration diagnostics and partial discharge techniques within the diagnostic systems of enterprises for automated control of the technical condition of rotating machinery during maintenance and at production facilities. The described solutions allow you to control the condition of mechanical and electrical components of rotating machines. It is shown that the functionality of the diagnostics systems can be expanded with minimal changes in technological chains of repair and operation of rotating machinery. Automation of such systems reduces the influence of the human factor on the quality of repair and diagnostics of the machinery.

  1. Mobile operators have set ambitious targets – Is it possible to boost network capacity while reducing its energy consumption?

    DEFF Research Database (Denmark)

    Micallef, Gilbert; Mogensen, Preben; Scheck, Hans-Otto

    2012-01-01

    While operators have to upgrade the capacity of their networks, they have committed themselves to reduce their CO2 emissions, partly by reducing their energy consumption. This article investigates the challenges faced by operators and quantifies, through a number of case studies, the impact...... the possible savings by adopting an energy-efficient capacity evolution together with an equipment replacement and site upgrade strategy. Results show that network operators can get relatively close to their targets, with energy reductions of up to 40% noted. While this can be improved further through software...... based energy saving features, further CO2 emissions can be offset through carbon-neutral energy sources....

  2. RFQ1 diagnostic devices

    International Nuclear Information System (INIS)

    Chidley, B.G.; Arbique, G.M.; de Jong, M.S.; McMichael, G.E.; Michel, W.L.; Smith, B.H.

    1991-01-01

    The diagnostic devices in use on RFQ1 will be described. They consist of a double-slit emittance-measuring unit, a 45 degree deflection energy-analysis magnet, parametric current transformers, optical beam sensors, beam-stop current monitors, and an x-ray end-point analyzer. All of these devices are able to operate up to the full output current of RFQ1 (75 mA cw at 0.6 MeV)

  3. Forge: a short pulse x-ray diagnostic development facility

    International Nuclear Information System (INIS)

    Stradling, G.L.; Hurry, T.R.; Denbow, E.R.; Selph, M.M.; Ameduri, F.P.

    1985-01-01

    A new short pulse x-ray calibration facility has been brought on line at Los Alamos. This facility is being used for the development, testing and calibration of fast x-ray diagnostic systems. The x-ray source consists of a moderate size, sub-nanosecond laser focused at high intensity on an appropriate target material to generate short pulses of x-ray emission from the resulting plasma. Dynamic performance parameters of fast x-ray diagnostic instruments, such as x-ray streak cameras, can be conveniently measured using this facility

  4. Applications of ROC analysis in diagnostic image evaluation

    International Nuclear Information System (INIS)

    Metz, C.E.

    1979-01-01

    The need for Receiver Operating Characteristic (ROC) analysis is indicated by a discussion of the limitations of accuracy and of sensitivity and specificity as indices of diagnostic detection or discrmination performance. The concept of a variable decision threshold is shown to lead in a natural way to the ROC curve as a means for specifying diagnostic performance. Practical techniques for measuring ROC curves are described, and directions for possible generalizations of conventional ROC analysis are indicated

  5. [Molecular and immunohistochemical diagnostics in melanoma].

    Science.gov (United States)

    Schilling, B; Griewank, K G

    2016-07-01

    To provide appropriate therapy and follow-up to patients with malignant melanoma, proper diagnostics are of critical importance. Targeted therapy of advanced melanoma is based on the molecular genetic analyses of tumor tissue. In addition, sequencing of genes and other genetic approaches can provide insight into the origin of melanocytic tumors and can aid in distinguishing benign from malignant lesions. In this regard, spizoid neoplasms remain a challenging entity. Aside from genetic analyses of tumor tissue, immunohistochemistry remains an essential tool in melanoma diagnostics and TNM classification. With new immunotherapies being approved for advanced melanoma, immunohistochemistry to determine PD-L1 expression has gained clinical interest. While PD-L1 expression is associated with response to PD-1 blockade, a substantial number of patients without PD-L1 expression can still experience tumor remission upon treatment. In this review, current and future developments in melanoma diagnostics with regard to molecular genetics and immunohistochemistry are summarized. The utilization of such analyses in clinical decision making is also discussed.

  6. Molecular diagnostics for lassa fever at Irrua specialist teaching hospital, Nigeria: lessons learnt from two years of laboratory operation.

    Directory of Open Access Journals (Sweden)

    Danny A Asogun

    Full Text Available BACKGROUND: Lassa fever is a viral hemorrhagic fever endemic in West Africa. However, none of the hospitals in the endemic areas of Nigeria has the capacity to perform Lassa virus diagnostics. Case identification and management solely relies on non-specific clinical criteria. The Irrua Specialist Teaching Hospital (ISTH in the central senatorial district of Edo State struggled with this challenge for many years. METHODOLOGY/PRINCIPAL FINDINGS: A laboratory for molecular diagnosis of Lassa fever, complying with basic standards of diagnostic PCR facilities, was established at ISTH in 2008. During 2009 through 2010, samples of 1,650 suspected cases were processed, of which 198 (12% tested positive by Lassa virus RT-PCR. No remarkable demographic differences were observed between PCR-positive and negative patients. The case fatality rate for Lassa fever was 31%. Nearly two thirds of confirmed cases attended the emergency departments of ISTH. The time window for therapeutic intervention was extremely short, as 50% of the fatal cases died within 2 days of hospitalization--often before ribavirin treatment could be commenced. Fatal Lassa fever cases were older (p = 0.005, had lower body temperature (p<0.0001, and had higher creatinine (p<0.0001 and blood urea levels (p<0.0001 than survivors. Lassa fever incidence in the hospital followed a seasonal pattern with a peak between November and March. Lassa virus sequences obtained from the patients originating from Edo State formed--within lineage II--a separate clade that could be further subdivided into three clusters. CONCLUSIONS/SIGNIFICANCE: Lassa fever case management was improved at a tertiary health institution in Nigeria through establishment of a laboratory for routine diagnostics of Lassa virus. Data collected in two years of operation demonstrate that Lassa fever is a serious public health problem in Edo State and reveal new insights into the disease in hospitalized patients.

  7. Targets development at Sandia National Laboratories

    International Nuclear Information System (INIS)

    Smith, M.L.; Hebron, D.; Derzon, M.; Olson, R.; Alberts, T.

    1997-01-01

    For many years, Sandia National Laboratories under contract to the Department of Energy has produced targets designed to understand complex ion beam and z-pinch plasma physics. This poster focuses on the features of target designs that make them suitable for Z-pinch plasma physics applications. Precision diagnostic targets will prove critical in understanding the plasma physics model needed for future ion beam and z-pinch design. Targets are designed to meet specific physics needs; in this case the authors have fabricated targets to maximize information about the end-on versus side-on x-ray emission and z-pinch hohlraum development. In this poster, they describe the fabrication and characterization techniques. They include discussion of current targets under development as well as target fabrication capabilities. Advanced target designs are fabricated by Sandia National Laboratories in cooperation with General Atomics of San Diego, CA and W.J. Schafer Associates, Inc. of Livermore, CA

  8. Development of procedures to ensure quality and integrity in Tandem Mirror Experiment-Upgrade (TMX-U) diagnostics systems

    International Nuclear Information System (INIS)

    Coutts, G.W.; Coon, M.L.; Hinz, A.F.; Hornady, R.S.; Lang, D.D.; Lund, N.P.

    1983-01-01

    The diagnostic systems for Tandem Mirror Experiment-Upgrade (TMX-U) have grown from eleven initial systems to more than twenty systems. During operation, diagnostic system modifications are sometimes required to complete experimental objectives. Also, during operations new diagnostic systems are being developed and implemented. To ensure and maintain the quality and integrity of the data signals, a set of plans and systematic actions are being developed. This paper reviews the procedures set in place to maintain the integrity of existing data systems and ensure the performance objectives of new diagnostics being added

  9. Pilots' Attention Distributions Between Chasing a Moving Target and a Stationary Target.

    Science.gov (United States)

    Li, Wen-Chin; Yu, Chung-San; Braithwaite, Graham; Greaves, Matthew

    2016-12-01

    Attention plays a central role in cognitive processing; ineffective attention may induce accidents in flight operations. The objective of the current research was to examine military pilots' attention distributions between chasing a moving target and a stationary target. In the current research, 37 mission-ready F-16 pilots participated. Subjects' eye movements were collected by a portable head-mounted eye-tracker during tactical training in a flight simulator. The scenarios of chasing a moving target (air-to-air) and a stationary target (air-to-surface) consist of three operational phases: searching, aiming, and lock-on to the targets. The findings demonstrated significant differences in pilots' percentage of fixation during the searching phase between air-to-air (M = 37.57, SD = 5.72) and air-to-surface (M = 33.54, SD = 4.68). Fixation duration can indicate pilots' sustained attention to the trajectory of a dynamic target during air combat maneuvers. Aiming at the stationary target resulted in larger pupil size (M = 27,105, SD = 6565), reflecting higher cognitive loading than aiming at the dynamic target (M = 23,864, SD = 8762). Pilots' visual behavior is not only closely related to attention distribution, but also significantly associated with task characteristics. Military pilots demonstrated various visual scan patterns for searching and aiming at different types of targets based on the research settings of a flight simulator. The findings will facilitate system designers' understanding of military pilots' cognitive processes during tactical operations. They will assist human-centered interface design to improve pilots' situational awareness. The application of an eye-tracking device integrated with a flight simulator is a feasible and cost-effective intervention to improve the efficiency and safety of tactical training.Li W-C, Yu C-S, Braithwaite G, Greaves M. Pilots' attention distributions between chasing a moving target and a stationary target. Aerosp Med

  10. Evaluation of the diagnostic performance and operational ...

    African Journals Online (AJOL)

    The objectives of the study were (i) to assess the sensitivity and specificity of four on site rapid tests in comparison with Treponema pallidum haemagglutination assay (TPHA) as a gold standard and (ii) to evaluate the operational characteristics of those tests among health workers in a maternity unit. Methods: Four rapid ...

  11. Overview of data acquisition system for SST-1 diagnostics

    International Nuclear Information System (INIS)

    Sharma, Manika; Mansuri, Imran; Raval, Tushar; Sharma, A.L; Pradhan, S.

    2016-01-01

    Highlights: • An account of architecture and data acquisition activities of SST-1 data acquisition system (DAS) for SST-1 diagnostics and subsystems. • PXI based Data acquisition system and CAMAC based Data acquisition system for slow and fast plasma diagnostics. • SST-1 DAS interface and its communication with SST-1 central control system. Integration of SST-1 DAS with timing system. • SST-1 DAS data archival and data analysis. - Abstract: The recent first phase operations of SST-1 in short pulse mode have provided an excellent opportunity for the essential initial tests and benchmark of the SST-1 Data Acquisition System. This paper describes the SST-1 Data Acquisition systems (DAS), which with its heterogeneous composition and distributed architecture, aims to cover a wide range of slow to fast channels interfaced with a large set of diagnostics. The DAS also provides the essential user interface for data acquisition to cater both on and off-line data usage. The central archiving and retrieval service is based on a dual step architecture involving a combination of Network Attached Server (NAS) and a Storage Area Network (SAN). SST-1 Data Acquisition Systems have been reliably operated in the SST-1 experimental campaigns. At present different distributed DAS caters the need of around 130 channels from different SST-1 diagnostics and its subsystems. PXI based DAS and CAMAC based DAS have been chosen to cater the need, with sampling rates varying from 10Ksamples/sec to 1Msamples/sec. For these large sets of channels acquiring from individual diagnostics and subsystems has been a combined setup, subjected to a gradual phase of optimization and tests resulting into a series of improvisations over the recent operations. In order to facilitate a reliable data acquisition, the model further integrates the objects of the systems with the Central Control System of SST-1 using the TCP/IP communication. The associated DAS software essentially addresses the

  12. Overview of data acquisition system for SST-1 diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Manika, E-mail: bithi@ipr.res.in; Mansuri, Imran; Raval, Tushar; Sharma, A.L; Pradhan, S.

    2016-11-15

    Highlights: • An account of architecture and data acquisition activities of SST-1 data acquisition system (DAS) for SST-1 diagnostics and subsystems. • PXI based Data acquisition system and CAMAC based Data acquisition system for slow and fast plasma diagnostics. • SST-1 DAS interface and its communication with SST-1 central control system. Integration of SST-1 DAS with timing system. • SST-1 DAS data archival and data analysis. - Abstract: The recent first phase operations of SST-1 in short pulse mode have provided an excellent opportunity for the essential initial tests and benchmark of the SST-1 Data Acquisition System. This paper describes the SST-1 Data Acquisition systems (DAS), which with its heterogeneous composition and distributed architecture, aims to cover a wide range of slow to fast channels interfaced with a large set of diagnostics. The DAS also provides the essential user interface for data acquisition to cater both on and off-line data usage. The central archiving and retrieval service is based on a dual step architecture involving a combination of Network Attached Server (NAS) and a Storage Area Network (SAN). SST-1 Data Acquisition Systems have been reliably operated in the SST-1 experimental campaigns. At present different distributed DAS caters the need of around 130 channels from different SST-1 diagnostics and its subsystems. PXI based DAS and CAMAC based DAS have been chosen to cater the need, with sampling rates varying from 10Ksamples/sec to 1Msamples/sec. For these large sets of channels acquiring from individual diagnostics and subsystems has been a combined setup, subjected to a gradual phase of optimization and tests resulting into a series of improvisations over the recent operations. In order to facilitate a reliable data acquisition, the model further integrates the objects of the systems with the Central Control System of SST-1 using the TCP/IP communication. The associated DAS software essentially addresses the

  13. Blood culture-negative endocarditis: Improving the diagnostic yield using new diagnostic tools.

    Science.gov (United States)

    Fournier, Pierre-Edouard; Gouriet, Frédérique; Casalta, Jean-Paul; Lepidi, Hubert; Chaudet, Hervé; Thuny, Franck; Collart, Frédéric; Habib, Gilbert; Raoult, Didier

    2017-11-01

    Blood culture-negative endocarditis (BCNE) may represent up to 70% of all endocarditis cases, depending on series. From 2001 to 2009, we implemented in our laboratory a multimodal diagnostic strategy for BCNE that included systematized testing of blood, and when available, valvular biopsy specimens using serological, broad range molecular, and histopathological assays. A causative microorganism was identified in 62.7% of patients.In this study from January 2010 to December 2015, in an effort to increase the number of identified causative microorganisms, we prospectively added to our diagnostic protocol specific real-time (RT) polymerase chain reaction (PCR) assays targeting various endocarditis agents, and applied them to all patients with BCNE admitted to the 4 public hospitals in Marseille, France.A total of 283 patients with BCNE were included in the study. Of these, 177 were classified as having definite endocarditis. Using our new multimodal diagnostic strategy, we identified an etiology in 138 patients (78.0% of cases). Of these, 3 were not infective (2.2%) and 1 was diagnosed as having Mycobacterium bovis BCG endocarditis. By adding specific PCR assays from blood and valvular biopsies, which exhibited a significantly greater sensitivity (P < 10) than other methods, causative agents, mostly enterococci, streptococci, and zoonotic microorganisms, were identified in an additional 27 patients (14 from valves only, 11 from blood only, and 2 from both). Finally, in another 107 patients, a pathogen was detected using serology in 37, valve culture in 8, broad spectrum PCR from valvular biopsies and blood in 19 and 2, respectively, immunohistochemistry from valves in 3, and a combination of several assays in 38.By adding specific RT-PCR assays to our systematic PCR testing of patients with BCNE, we increased the diagnostic efficiency by 24.3%, mostly by detecting enterococci and streptococci that had not been detected by other diagnostic methods, but also agents

  14. Liquid helium target

    International Nuclear Information System (INIS)

    Fujii, Y.; Kitami, T.; Torikoshi, M.

    1984-12-01

    A liquid helium target system has been built and used for the experiment on the reaction 4 He(γ, p). The target system has worked satisfactorily; the consumption rate of liquid helium is 360 ml/h and the cryogenic system retains liquid helium for about ten hours. The structure, operation and performance of the target system are reported. (author)

  15. Principles of validation of diagnostic assays for infectious diseases

    International Nuclear Information System (INIS)

    Jacobson, R.H.

    1998-01-01

    Assay validation requires a series of inter-related processes. Assay validation is an experimental process: reagents and protocols are optimized by experimentation to detect the analyte with accuracy and precision. Assay validation is a relative process: its diagnostic sensitivity and diagnostic specificity are calculated relative to test results obtained from reference animal populations of known infection/exposure status. Assay validation is a conditional process: classification of animals in the target population as infected or uninfected is conditional upon how well the reference animal population used to validate the assay represents the target population; accurate predictions of the infection status of animals from test results (PV+ and PV-) are conditional upon the estimated prevalence of disease/infection in the target population. Assay validation is an incremental process: confidence in the validity of an assay increases over time when use confirms that it is robust as demonstrated by accurate and precise results; the assay may also achieve increasing levels of validity as it is upgraded and extended by adding reference populations of known infection status. Assay validation is a continuous process: the assay remains valid only insofar as it continues to provide accurate and precise results as proven through statistical verification. Therefore, the work required for validation of diagnostic assays for infectious diseases does not end with a time-limited series of experiments based on a few reference samples rather, to assure valid test results from an assay requires constant vigilance and maintenance of the assay, along with reassessment of its performance characteristics for each unique population of animals to which it is applied. (author)

  16. Diagnostics of Primary Immunodeficiencies through Next Generation Sequencing

    Directory of Open Access Journals (Sweden)

    Vera Gallo

    2016-11-01

    Full Text Available Background: Recently, a growing number of novel genetic defects underlying primary immunodeficiencies (PID have been identified, increasing the number of PID up to more than 250 well-defined forms. Next-generation sequencing (NGS technologies and proper filtering strategies greatly contributed to this rapid evolution, providing the possibility to rapidly and simultaneously analyze large numbers of genes or the whole exome. Objective: To evaluate the role of targeted next-generation sequencing and whole exome sequencing in the diagnosis of a case series, characterized by complex or atypical clinical features suggesting a PID, difficult to diagnose using the current diagnostic procedures.Methods: We retrospectively analyzed genetic variants identified through targeted next-generation sequencing or whole exome sequencing in 45 patients with complex PID of unknown etiology. Results: 40 variants were identified using targeted next-generation sequencing, while 5 were identified using whole exome sequencing. Newly identified genetic variants were classified into 4 groups: I variations associated with a well-defined PID; II variations associated with atypical features of a well-defined PID; III functionally relevant variations potentially involved in the immunological features; IV non-diagnostic genotype, in whom the link with phenotype is missing. We reached a conclusive genetic diagnosis in 7/45 patients (~16%. Among them, 4 patients presented with a typical well-defined PID. In the remaining 3 cases, mutations were associated with unexpected clinical features, expanding the phenotypic spectrum of typical PIDs. In addition, we identified 31 variants in 10 patients with complex phenotype, individually not causative per se of the disorder.Conclusion: NGS technologies represent a cost-effective and rapid first-line genetic approaches for the evaluation of complex PIDs. Whole exome sequencing, despite a moderate higher cost compared to targeted, is

  17. The diagnostic adaptive behavior scale: evaluating its diagnostic sensitivity and specificity.

    Science.gov (United States)

    Balboni, Giulia; Tassé, Marc J; Schalock, Robert L; Borthwick-Duffy, Sharon A; Spreat, Scott; Thissen, David; Widaman, Keith F; Zhang, Dalun; Navas, Patricia

    2014-11-01

    The Diagnostic Adaptive Behavior Scale (DABS) was constructed with items across three domains--conceptual, social, and practical adaptive skills--and normed on a representative sample of American individuals from 4 to 21 years of age. The DABS was developed to focus its assessment around the decision point for determining the presence or absence of significant limitations of adaptive behavior for the diagnosis of Intellectual Disability (ID). The purpose of this study, which was composed of 125 individuals with and 933 without an ID-related diagnosis, was to determine the ability of the DABS to correctly identify the individuals with and without ID (i.e., sensitivity and specificity). The results indicate that the DABS sensitivity coefficients ranged from 81% to 98%, specificity coefficients ranged from 89% to 91%, and that the Area Under the Receiver Operating Characteristic Curve were excellent or good. These results indicate that the DABS has very good levels of diagnostic efficiency. Copyright © 2014. Published by Elsevier Ltd.

  18. Companion diagnostics and molecular imaging-enhanced approaches for oncology clinical trials.

    Science.gov (United States)

    Van Heertum, Ronald L; Scarimbolo, Robert; Ford, Robert; Berdougo, Eli; O'Neal, Michael

    2015-01-01

    In the era of personalized medicine, diagnostic approaches are helping pharmaceutical and biotechnology sponsors streamline the clinical trial process. Molecular assays and diagnostic imaging are routinely being used to stratify patients for treatment, monitor disease, and provide reliable early clinical phase assessments. The importance of diagnostic approaches in drug development is highlighted by the rapidly expanding global cancer diagnostics market and the emergent attention of regulatory agencies worldwide, who are beginning to offer more structured platforms and guidance for this area. In this paper, we highlight the key benefits of using companion diagnostics and diagnostic imaging with a focus on oncology clinical trials. Nuclear imaging using widely available radiopharmaceuticals in conjunction with molecular imaging of oncology targets has opened the door to more accurate disease assessment and the modernization of standard criteria for the evaluation, staging, and treatment responses of cancer patients. Furthermore, the introduction and validation of quantitative molecular imaging continues to drive and optimize the field of oncology diagnostics. Given their pivotal role in disease assessment and treatment, the validation and commercialization of diagnostic tools will continue to advance oncology clinical trials, support new oncology drugs, and promote better patient outcomes.

  19. Diagnostic accuracy of organ electrodermal diagnostics | Szopinski ...

    African Journals Online (AJOL)

    Objective. To estimate the diagnostic accuracy as well as the scope of utilisation of a new bio-electronic method of organ diagnostics. Design. Double-blind comparative study of the diagnostic results obtained by means of organ electrodermal diagnostics (OED) and clinical diagnoses, as a criterion standard. Setting.

  20. Primary myelofibrosis: own experience and news from diagnostic and treatment

    Directory of Open Access Journals (Sweden)

    K. M. Abdulkadyrov

    2015-06-01

    Full Text Available The newest advances in primary myelofibrosis (PMF pathogenesis study, diagnostic and treatment approaches are presented in this article. The JAK-STAT signal pathway activation now recognized as main pathogenesis mechanism of PMF, it caused by JAK2, CALR, MPL genes mutations. Authors demonstrate their own data about epidemiology, clinical signs, diagnostic and treatment results of 315 PMF patients. The most frequent clinical symptoms are: anemia, leukocytosis, thrombocytosis, splenomegaly, constitutional symptoms. Diagnostic criteria, prognostic scales (including cytogenetic and molecular features issues are reviewed. Intermediate-1 risk grade is in the most proportion of patients. Therecommended PMF treatment algorithm is listed. The treatment methods, target drugs (Janus kinases inhibitors trials results are discussed.

  1. Primary myelofibrosis: own experience and news from diagnostic and treatment

    Directory of Open Access Journals (Sweden)

    K. M. Abdulkadyrov

    2015-01-01

    Full Text Available The newest advances in primary myelofibrosis (PMF pathogenesis study, diagnostic and treatment approaches are presented in this article. The JAK-STAT signal pathway activation now recognized as main pathogenesis mechanism of PMF, it caused by JAK2, CALR, MPL genes mutations. Authors demonstrate their own data about epidemiology, clinical signs, diagnostic and treatment results of 315 PMF patients. The most frequent clinical symptoms are: anemia, leukocytosis, thrombocytosis, splenomegaly, constitutional symptoms. Diagnostic criteria, prognostic scales (including cytogenetic and molecular features issues are reviewed. Intermediate-1 risk grade is in the most proportion of patients. Therecommended PMF treatment algorithm is listed. The treatment methods, target drugs (Janus kinases inhibitors trials results are discussed.

  2. Radiation hardening of diagnostics

    International Nuclear Information System (INIS)

    Siemon, R.E.

    1991-01-01

    The world fusion program has advanced to the stage where it is appropriate to construct a number of devices for the purpose of burning DT fuel. In these next-generation experiments, the expected flux and fluence of 14 MeV neutrons and associated gamma rays will pose a significant challenge to the operation and diagnostics of the fusion device. Radiation effects include structural damage to materials such as vacuum windows and seals, modifications to electrical properties such as electrical conductivity and dielectric strength and impaired optical properties such as reduced transparency and luminescence of windows and fiber optics during irradiation. In preparation for construction and operation of these new facilities, the fusion diagnostics community needs to work with materials scientists to develop a better understanding of radiation effects, and to undertake a testing program aimed at developing workable solutions for this multi-faceted problem. A unique facility to help in this regard is the Los Alamos Spallation Radiation Effects Facility, a neutron source located at the beam stop of the world's most powerful accelerator, the Los Alamos Meson Physics Facility (LAMPF). The LAMPF proton beam generates 10 16 neutrons per second because of ''spallation'' reactions when the protons collide with the copper nuclei in the beam stop

  3. Nanoparticles for therapeutic and diagnostic applications

    OpenAIRE

    Chiu, Yin To

    2014-01-01

    Nanomedicine focuses on the development and engineering of novel and unique therapeutic and diagnostic agents that can overcome the challenges associated with using traditional modalities. Nanoparticles (NPs) in the size range between 1 and 1000 nm have many advantages for use in these applications, such as, low polydispersity, established characterization methodologies, and the ability to be loaded with therapeutics for diseases, conjugated to targeting ligands to enhance specificity, and co...

  4. Electron beam diagnostic system using computed tomography and an annular sensor

    Science.gov (United States)

    Elmer, John W.; Teruya, Alan T.

    2014-07-29

    A system for analyzing an electron beam including a circular electron beam diagnostic sensor adapted to receive the electron beam, the circular electron beam diagnostic sensor having a central axis; an annular sensor structure operatively connected to the circular electron beam diagnostic sensor, wherein the sensor structure receives the electron beam; a system for sweeping the electron beam radially outward from the central axis of the circular electron beam diagnostic sensor to the annular sensor structure wherein the electron beam is intercepted by the annular sensor structure; and a device for measuring the electron beam that is intercepted by the annular sensor structure.

  5. Advances in point-of-care technologies for molecular diagnostics.

    Science.gov (United States)

    Zarei, Mohammad

    2017-12-15

    Advances in miniaturization, nanotechnology, and microfluidics, along with developments in cloud-connected point-of-care (POC) diagnostics technologies are pushing the frontiers of POC devices toward low-cost, user-friendly, and enhanced sensitivity molecular-level diagnostics. The combination of various bio-sensing platforms within smartphone-integrated electronic readers provides accurate on-site and on-time diagnostics based on various types of chemical and biological targets. Further, 3D printing technology shows a huge potential toward fabrication and improving the performance of POC devices. Integration of skin-like flexible sensors with wireless communication technology creates a unique opportunity for continuous, real-time monitoring of patients for both preventative healthcare and during disease outbreaks. Here, we review recent developments and advances in POC technologies and describe how these advances enhance the performance of POC platforms. Also, this review describes challenges, directions, and future trends on application of emerging technologies in POC diagnostics. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Mammary carcinoma diagnostics and therapy; Diagnostik und Therapie des Mammakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, Uwe; Baum, Friedemann (eds.) [Diagnostisches Brustzentrum Goettingen BZG, Goettingen(Germany)

    2014-11-01

    The book on mammary carcinoma diagnostics and therapy covers the following issues: development, anatomy and physiology of the mammary glands, pathology of benign and malign mammary gland changes, non-imaging diagnostics; mammography; ultrasonic mammography; magnetic resonance tomography of the mammary glands; imaging diagnostics findings; mammary interventions; examination concepts; operative therapy of the mammary carcinoma; chemotherapy of the mammary carcinoma; radio-oncological therapy of the mammary carcinoma; logistics in a medical center for mammary gland diseases; logistics in an interdisciplinary center for mammary diseases; dialogue conduction and psycho-social attendance.

  7. The Effect of Molecular Diagnostics on the Treatment of Glioma.

    Science.gov (United States)

    Bush, Nancy Ann Oberheim; Butowski, Nicholas

    2017-04-01

    This review summarizes the use of molecular diagnostics in glioma and its effect on the development of novel therapeutics and management decisions. Genomic and proteomic profiling of brain tumors has provided significant expansion of our understanding of oncogenesis, characterization, and prognostication of brain tumors. Molecular markers such as MGMT, EGFR, IDH, 1p19q, ATRX, TERT, FGFR-TACC, and BRAF are now being used to classify brain tumors as well as influence management decisions. Several of these markers are also being used as therapeutic targets. We review the use of several molecular diagnostics in gliomas and discuss their impact on drug development and clinical trial design. In the future, molecular characterization based on a specific genomic, proteomic as well as transcriptomes for bioformatics analysis will provide clinicians the ability to rationally select drugs with actionable targets for each patient.

  8. Development and implementation of plant diagnostic skills training

    International Nuclear Information System (INIS)

    Iwatare, K.; Noji, K.

    2010-01-01

    It was learned from the July 2007 Chuetsu-oki Earthquake that a need exists for simulator training methods to be revised to include the assumption of multiple failures such as those which may occur during a large earthquake. At BWR Operator Training Center Corp., multiple failure team training which focuses on plant diagnostic skills (Plant Diagnostic Skills Training) has been developed and implemented since September 2008. The contents of this training along with the results are presented and considered in this paper. (author)

  9. Evidence-based medical research on diagnostic criteria and screening technique of vascular mild cognitive impairment

    Directory of Open Access Journals (Sweden)

    Xia-wei LIU

    2015-07-01

    Full Text Available Background Vascular mild cognitive impairment (VaMCI is the prodromal syndrome of vascular dementia (VaD and key target for drug treatment. There is controversy over the diagnostic criteria and screening tools of VaMCI, which affects its clinical diagnosis. This paper aims to explore the clinical features, diagnostic criteria and screening technique of VaMCI.  Methods Taking "vascular mild cognitive impairment OR vascular cognitive impairment no dementia" as retrieval terms, search in PubMed database from January 1997 to March 2015 and screen relevant literatures concerning VaMCI. According to Guidance for the Preparation of Neurological Management Guidelines revised by European Federation of Neurological Societies (EFNS in 2004, evidence grading was performed on literatures. Results A total of 32 literatures in English were selected according to inclusion and exclusion criteria, including 3 guidelines and consensus and 29 clinical studies. Seven literatures (2 on Level Ⅰ, 5 on Level Ⅱ studied on neuropsychological features in VaMCI patients and found reduced processing speed and executive function impairment were main features. Two literatures reported the diagnostic criteria of VaMCI, including VaMCI criteria published by American Heart Association (AHA/American Stroke Association (ASA in 2011 and "Diagnostic Criteria for Vascular Cognitive Disorders" published by International Society for Vascular Behavioral and Cognitive Disorders (VASCOG in 2014. Fifteen literatures (4 on LevelⅠ, 11 on Level Ⅱ described the diagnostic criteria of VaMCI used in clinical research, from which 6 operational diagnostic items were extracted. Fourteen literatures (4 on Level Ⅰ, 10 on Level Ⅱ described neuropsychological assessment tools for VaMCI screening, and found the 5-minute protocol recommended by National Institute of Neurological Disorders and Stroke-Canadian Stroke Network (NINDS-CSN was being good consistency with other neuropsychological

  10. Dentistry 4. X-ray diagnostics

    International Nuclear Information System (INIS)

    2014-01-01

    DIN pocketbook 267/4 gives an overview of the normative requirements of the new X-Ray and Radiation Protection Ordinance, which has been in effect since 1 November 2011. This DIN pocketbook is intended for anyone charged with professional responsibility for the use of ionizing radiation in dentistry, operators and users of x-ray devices, radiation protection officers, accredited experts, manufacturers as well as for anyone with an interest in radiation protection or optimal radiological diagnostics. It contains standards relating to the following areas: acceptance and constancy testing; devices for evaluating findings (monitors, film viewing devices), films, printers; archiving, designating, labelling. Adherence to the standards makes it possible to avoid distractive artefacts in x-ray images and optimise the quality of x-ray diagnostics in dentistry.

  11. CIT diagnostic computer interface studies

    International Nuclear Information System (INIS)

    Rauch, W.; Hayes, S.; Lowrance, J.; Oliaro, G.; Sauthoff, N.; Sichta, P.; Stark, W.

    1987-01-01

    This paper presents the on-going work performed in proposing instrumentation equipment and communications networks for the Diagnostic Data Acquisition and Diagnostic Instrumentation and Control System for the Compact Ignition Torus (CIT), which will begin operation in 1993. Consideration is given to the system criteria and requirements and their influence on the appropriate application of instrumentation and communication technologies to the system. This paper concentrates on the investigation of the bus communication technologies as they apply to the CIT data acquisition system. It compares CAMAC, VME, and FASTBUS as standards for data acquisition. The paper describes the connectivity between VAX equipment and CAMAC and VME instrumentation systems. Instrumentation and communication functionality and performance levels are presented as factors important to the overall data acquisition system performance

  12. Why Won't You Drop, Damn YouZ? An Examination of the Targeting Process in Operation Enduring Freedom and its Implications

    National Research Council Canada - National Science Library

    Kindley, David

    2004-01-01

    ...?. This paper will examine the decision making process for rapid targeting in OEF from the strike fighter pilot through the watch officer in the Combined Air Operations Center at Prince Sultan Air Base...

  13. Investigations with diagnostic fuel rod bundles on Rheinsberg NPP

    International Nuclear Information System (INIS)

    Krauze, F.; Rudolf, G.; Shajfler, V.; Tsimke, K.

    1982-01-01

    In 70MW pressurized water reactor of Rheinsberg NPP diagnostic fuel rod bundles have been installed: first of DK 1 type and then of DK 2 advanced type. Three rounds of measurement were run with DK 1 bundle and one with DK 2. The diagnostic bundles are equiped with various sensors for temperature, pressure, neutron flux and mechanical stress measurements as well as with special flow rate control system which allows to reach coolant boiling within the bundle. Qualitative and quantitative description of the sensors performance during reactor operation is given. The presented experimental results are connected with: 1) working capability of the measuring devices and their calibration; 2) throttling and boiling in two regimes: a) stationary and non-stationary flow rate throbgh DK during stationary reactor operation; b) various constant levels of flow rate through DK during non-stationary reactor operation regime [ru

  14. Integration of the ITER diagnostic plant systems with CODAC

    International Nuclear Information System (INIS)

    Simrock, S.; Barnsley, R.; Bertalot, L.; Hansalia, C.; Klotz, W.D.; Makijarvi, P.; Reichle, R.; Vayakis, G.; Yonekawa, I.; Walker, C.; Wallander, A.; Walsh, M.; Winter, A.

    2011-01-01

    ITER requires extensive diagnostic systems in order to meet the requirements for machine operation, protection, plasma control and physics studies. The realization of these systems is a major challenge not only because of the harsh environment and the nuclear requirements but also with respect to Instrumentation and Control (I and C) of all the 59 diagnostics plants. The Plant Systems I and C are mostly 'in-kind', i.e. procured by the seven ITER Domestic Agencies (DAs), while the Central I and C Systems are 'in-fund', i.e. procured by ITER Organization (IO). Standardization of Plant Systems I and C is of primary importance and has been one of the highest priority tasks of CODAC. The standards are published in the Plant Control Design Handbook (PCDH) which will be followed to ensure a homogeneous design, guarantee high availability and simplify maintenance and support future upgrades. Most important for a successful commissioning and operation of the ITER facility are the concepts of interfacing the diagnostics plant systems with CODAC and the standards for instrumentation and control which must be followed all contributing parties. In this paper, we will elaborate on the concepts of interfacing the diagnostics plant systems with CODAC and the standards that must be followed for the design.

  15. Point-of-care technologies for molecular diagnostics using a drop of blood.

    Science.gov (United States)

    Song, Yujun; Huang, Yu-Yen; Liu, Xuewu; Zhang, Xiaojing; Ferrari, Mauro; Qin, Lidong

    2014-03-01

    Molecular diagnostics is crucial for prevention, identification, and treatment of disease. Traditional technologies for molecular diagnostics using blood are limited to laboratory use because they rely on sample purification and sophisticated instruments, are labor and time intensive, expensive, and require highly trained operators. This review discusses the frontiers of point-of-care (POC) diagnostic technologies using a drop of blood obtained from a finger prick. These technologies, including emerging biotechnologies, nanotechnologies, and microfluidics, hold the potential for rapid, accurate, and inexpensive disease diagnostics. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Targeted Therapies for Myeloma and Metastatic Bone Cancers

    Science.gov (United States)

    2010-09-01

    Cancer J Clin 2003; 53:5. Kasugai S, Fujisawa R, Waki Y, Miyamoto K, Ohya K 2000 Selective drug delivery system to bone: small peptide (Asp)6...page. Bone targeted nanoparticles , bone cancer myeloma, mice studies, PLGA , Biodegradable materials. Targeted Therapies for Myeloma and Metastatic Bone...present results from this program at talk at the Particles 2006 –Medical/Biochemical Diagnostic , Pharmaceutical, and Drug Delivery . 3

  17. 30 CFR 250.520 - When do I have to perform a casing diagnostic test?

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false When do I have to perform a casing diagnostic... Operations Casing Pressure Management § 250.520 When do I have to perform a casing diagnostic test? (a) You must perform a casing diagnostic test within 30 days after first observing or imposing casing pressure...

  18. Bi-photon imaging and diagnostics using ultra-small diagnostic probes engineered from semiconductor nanocrystals and single-domain antibodies

    Science.gov (United States)

    Hafian, Hilal; Sukhanova, Alyona; Chames, Patrick; Baty, Daniel; Pluot, Michel; Cohen, Jacques H. M.; Nabiev, Igor R.; Millot, Jean-Marc

    2012-10-01

    Semiconductor fluorescent quantum dots (QDs) have just demonstrated their numerous advantages over organic dyes in bioimaging and diagnostics. One of characteristics of QDs is a very large cross section of their twophoton absorption. A common approach to biodetection by means of QDs is to use monoclonal antibodies (mAbs) for targeting. Recently, we have engineered ultrasmall diagnostic nanoprobes (sdAb-QD) based on highly oriented conjugates of QDs with the single-domain antibodies (sdAbs) against cancer biomarkers. With a molecular weight of only 13 kDa (12-fold smaller than full-size mAbs) and extreme stability and capacity to refolding, sdAbs are the smallest functional Ab fragments capable of binding antigens with affinities comparable to those of conventional Abs. Ultrasmall diagnostic sdAb-QD nanoprobes were engineered through oriented conjugation of QDs with sdAbs. This study is the first to demonstrate the possibility of immunohistochemical imaging of colon carcinoma biomarkers with sdAb-QD conjugates by means of two-photon excitation. The optimal excitation conditions for imaging of the markers in clinical samples with sdAb-QD nanoprobes have been determined. The absence of sample autofluorescence significantly improves the sensitivity of biomarker detection with the use of the two-photon excitation diagnostic setup.

  19. Podocytes from the diagnostic and therapeutic point of view.

    Science.gov (United States)

    Müller-Deile, Janina; Schiffer, Mario

    2017-08-01

    The central role of podocytes in glomerular diseases makes this cell type an interesting diagnostic tool as well as a therapeutic target. In this review, we discuss the current literature on the use of podocytes and podocyte-specific markers as non-invasive diagnostic tools in different glomerulopathies. Furthermore, we highlight the direct effects of drugs currently used to treat primary glomerular diseases and describe their direct cellular effects on podocytes. A new therapeutic potential is seen in drugs targeting the podocytic actin cytoskeleton which is essential for podocyte foot process structure and function. Incubation of cultured human podocyte cell lines with sera from patients with active glomerular diseases is currently also used to identify novel circulating factors with pathophysiological relevance for the glomerular filtration barrier. In addition, treatment of detached urinary podocytes from patients with substances that restore their cytoskeleton might serve as a novel personalized tool to estimate their potential for podocyte recovery ex vivo.

  20. GPIB based instrumentation and control system for ADITYA Thomson Scattering Diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Kiran, E-mail: kkpatel@ipr.res.in; Pillai, Vishal; Singh, Neha; Chaudhary, Vishnu; Thomas, Jinto; Kumar, Ajai

    2016-11-15

    The ADITYA Thomson Scattering Diagnostic is a single point Ruby laser based system with a spectrometer for spectral dispersion and photomultiplier tubes for the detection of scattered light. The system uses CAMAC (Computer Automated Measurement And Control) based control and data acquisition system, which synchronizes the Ruby laser, detectors and the digitizer. Previously used serial based CAMAC controller is upgraded to GPIB (General Purpose Interface Bus) based CAMAC controller for configuration and data transfer. The communication protocols for different instruments are converted to a single GPIB based for better interface. The entire control and data acquisition program is developed on LabVIEW platform for versatile operation of diagnostics with improved user friendly GUI (Graphical User Interfaces) and allows user to remotely update the laser firing time with respect to the plasma shot. The software is in handshake with the Tokamak main control program through network to minimize manual interventions for the operation of the diagnostics. The upgraded system improved the performance of the diagnostics in comparison to earlier in terms of better data transmission rate, easy to maintain and program is upgradable.