WorldWideScience

Sample records for tandem quadrupole mass

  1. Electrospray ionization quadrupole time-of-flight tandem mass spectrometric analysis of hexamethylenediamine-modified maltodextrin and dextran

    NARCIS (Netherlands)

    Sisu, E.; Bosker, W.T.E.; Norde, W.; Slaghek, T.M.; Timmermans, J.W.; Peter-Katalinić, J.; Cohen-Stuart, M.A.; Zamfir, A.D.

    2006-01-01

    A combined methodology for obtaining at the preparative scale and characterization by nanoelectrospray ionization (nanoESI) quadrupole time-of-flight (QTOF) mass spectrometry (MS) and tandem MS (MS/MS) of linear polysaccharides modified at the reducing end is presented. Two polydisperse

  2. Phosphopeptide detection and sequencing by matrix-assisted laser desorption/ionization quadrupole time-of-flight tandem mass spectrometry

    DEFF Research Database (Denmark)

    Bennett, Keiryn L; Stensballe, Allan; Podtelejnikov, Alexandre V

    2002-01-01

    A prototype matrix-assisted laser desorption/ionization quadrupole time-of-flight (MALDI-TOF) tandem mass spectrometer was used to sequence a series of phosphotyrosine-, phosphothreonine- and phosphoserine-containing peptides. The high mass resolution and mass accuracy of the instrument allowed...... ion at m/z 216.04 was observed in these MALDI low-energy CID tandem mass spectra. Elimination of phosphate groups was evident from the triphosphorylated peptide but not from the monophosphorylated species. The main fragmentation pathway for the synthetic phosphothreonine-containing peptide...

  3. [Determination of congo red in beef by high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry and ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry].

    Science.gov (United States)

    Lin, Hui; Xu, Chunxiang; Yan, Chunrong; Zhang, Zheng; Wang, Suilou

    2013-09-01

    A method was developed for the determination of congo red in beef. The analyte was identified by high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry (LC-QTOF MS) and quantitatively determined by ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry. After purified by liquid-liquid extraction, the congo red in the beef sample was separated on an Agilent ZORBAX Eclipse Plus C18 Rapid Resolution HD UPLC column (50 mm x 2.1 mm, 1.8 microm) HPLC , using 95% (volume percentage) methanol as the mobile phase at 0.2 mL/min. The detection was performed on an AB 4000 + triple quadrupole mass spectrometer utilizing electrospray ionization (ESI) interface operated in negative ion mode and multiple-reaction monitoring (MRM) mode. The results showed that the linear range of congo red mass concentration was 0.03 - 1 mg/L with the correlation coefficient of 0.999 8. The method had a good precision with the RSDs lower than 5% and the recoveries ranging from 88% to 91%. The limit of detection (LOD) of congo red was 0.01 mg/L. With good reproducibility, the method is simple, fast and effective for the determination of the illegally added congo red in beef and other meat products.

  4. Matrix interference evaluation employing GC and LC coupled to triple quadrupole tandem mass spectrometry.

    Science.gov (United States)

    Uclés, S; Lozano, A; Sosa, A; Parrilla Vázquez, P; Valverde, A; Fernández-Alba, A R

    2017-11-01

    Gas and liquid chromatography coupled to triple quadrupole tandem mass spectrometry are currently the most powerful tools employed for the routine analysis of pesticide residues in food control laboratories. However, whatever the multiresidue extraction method, there will be a residual matrix effect making it difficult to identify/quantify some specific compounds in certain cases. Two main effects stand out: (i) co-elution with isobaric matrix interferents, which can be a major drawback for unequivocal identification, and therefore false negative detections, and (ii) signal suppression/enhancement, commonly called the "matrix effect", which may cause serious problems including inaccurate quantitation, low analyte detectability and increased method uncertainty. The aim of this analytical study is to provide a framework for evaluating the maximum expected errors associated with the matrix effects. The worst-case study contrived to give an estimation of the extreme errors caused by matrix effects when extraction/determination protocols are applied in routine multiresidue analysis. Twenty-five different blank matrices extracted with the four most common extraction methods used in routine analysis (citrate QuEChERS with/without PSA clean-up, ethyl acetate and the Dutch mini-Luke "NL" methods) were evaluated by both GC-QqQ-MS/MS and LC-QqQ-MS/MS. The results showed that the presence of matrix compounds with isobaric transitions to target pesticides was higher in GC than under LC in the experimental conditions tested. In a second study, the number of "potential" false negatives was evaluated. For that, ten matrices with higher percentages of natural interfering components were checked. Additionally, the results showed that for more than 90% of the cases, pesticide quantification was not affected by matrix-matched standard calibration when an interferent was kept constant along the calibration curve. The error in quantification depended on the concentration level. In a

  5. A gas chromatography-tandem quadrupole mass spectrometric analysis of policosanols in commercial vegetable oils.

    Science.gov (United States)

    Jung, Dong Min; Lee, Mi Jin; Yoon, Suk Hoo; Jung, Mun Yhung

    2011-08-01

    Reportedly policosanols (PCs) have various beneficial functionalities on health. A gas chromatography-tandem mass spectrometry (GC-MS/MS) with a low limit of detection (LOD), and high specificity, recovery, and precision was successfully established for the PC analysis in vegetable oils. The LODs for the PCs were in the range of 0.002 to 0.016 μg/mL. The relative standard deviation (RSD) for the repeated analysis of PCs was less than 3.356%. The mean recoveries for spiked heptacosanol and octacosanol in vegetable oil were 102.3% and 106.3%, respectively. The total PC contents in the vegetable oils varied from 3.01 to 427.83 mg/kg oil. Perilla seed, grape seed, and rice bran oils were found to be highly rich sources of PCs, containing 427.83, 245.15, and 171.17 mg PCs/kg oil, respectively. Corn, sesame, and soybean oils contained only a negligible quantity of PCs. The PC composition in vegetable oils was greatly source dependent. In perilla seed oil, octacosanol was the single most predominant component, representing 55.93% of the total PC. In grape seed oil, however, hexacosanol is the most abundant PC, followed by octacosanol, tetracosanol, and triacontanol in a decreasing order. The major PCs in rice bran oil were triacontanol, octacosanol, hexacosanol, and tetracosanol, which constituted over 87.3% of the total PC. This represents the 1st report on the composition and contents of PC in most vegetable oils analyzed here. The information might be used for the development of vegetable oil products with beneficial functionality. © 2011 Institute of Food Technologists®

  6. Determination of polychlorinated biphenyls in ambient air by gas chromatography coupled to triple quadrupole tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Martinez Ocana, Rosa; Mena Granero, Angela; Egea Gonzalez, Francisco J.; Garrido Frenich, Antonia; Martinez Vidal, Jose L.; Plaza Bolanos, Patricia [University of Almeria, Department of Analytical Chemistry, Almeria (Spain)

    2008-03-15

    A multiresidue method for determining 22 polychlorinated biphenyls (PCBs) in air has been developed and validated by gas chromatography (GC) coupled to tandem mass spectrometry (MS/MS) using a triple quadrupole analyzer (QqQ). The method was validated in terms of both steps of sampling and analysis. The sampling method, which is based on active sampling using polyurethane foam (PUF) as adsorbent, was validated by generating standard atmospheres. The retention capacity of this sampling sorbent allows up to 5 m{sup 3} of air to be sampled without any breakthrough for most compounds. Two solvent extraction methods were compared: sonication and Soxhlet extraction with a mixture of n-hexane:diethyl ether (95:5 v/v). Both extraction methods yielded similar results, but the first one required less solvent and time. The method exhibited good accuracy (80.3-99.8%), precision (2.2-15.2%) and lower limits that allowed quantification and confirmation at levels as low as 0.008 ng/m{sup 3}. Finally, the method was applied to the analysis of PCBs in the air in areas near to a municipal solid-waste landfill and directly above the refuse in the landfill, where it indicated the presence of some of the target compounds. (orig.)

  7. Determinations of airborne synthetic musks by polyurethane foam coupled with triple quadrupole gas chromatography tandem mass spectrometer.

    Science.gov (United States)

    Wang, I-Ting Ivy; Cheng, Shu-Fang; Tsai, Shih-Wei

    2014-02-21

    Synthetic musk is widely used in various scented consumer products. However, the exposure via inhalation is often ignored due to pleasant smells. In addition, the information regarding the distribution of synthetic musk in air is limited. Hence, this research is aimed to develop a highly sensitive and widely applicable method for the determination of airborne synthetic musk. In this study, polyurethane foam (PUF) and filter were employed for active air sampling. Microwave assisted extraction (MAE) and nitrogen evaporator were performed for sample preparation. A gas chromatography coupled with triple quadrupole tandem mass spectrometer (GC/MS-MS) with specific multiple reaction monitoring (MRM) transition pairs was applied for sample analysis. Compared with using selected ion monitoring (SIM) mode traditionally, the sensitivities were improved in this study about an order at least. In terms of air concentration, as low as 0.48ngm(-3) can be determined when sampling at 3.5Lmin(-1) for 8h. The method established was further applied to the analysis of synthetic musk compounds in air samples collected in a cosmetics plant. The results showed that the airborne concentrations of gaseous polycyclic musk, gaseous nitro-musk, and particle-phase polycyclic musk were 6.4×10(2), 4.0×10(1) and 3.1×10(2)ngm(-3), respectively. Meanwhile, Cashmeran, Celstolide, Galaxolide, and Tonalide were found as the dominant musk compounds in the factory investigated. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Determination of Albendazole and Metabolites in Silkworm Bombyx mori Hemolymph by Ultrafast Liquid Chromatography Tandem Triple Quadrupole Mass Spectrometry

    Science.gov (United States)

    Li, Li; Xing, Dong-Xu; Li, Qing-Rong; Xiao, Yang; Ye, Ming-Qiang; Yang, Qiong

    2014-01-01

    Albendazole is a broad-spectrum parasiticide with high effectiveness and low host toxicity. No method is currently available for measuring albendazole and its metabolites in silkworm hemolymph. This study describes a rapid, selective, sensitive, synchronous and reliable detection method for albendazole and its metabolites in silkworm hemolymph using ultrafast liquid chromatography tandem triple quadrupole mass spectrometry (UFLC-MS/MS). The method is liquid-liquid extraction followed by UFLC separation and quantification in an MS/MS system with positive electrospray ionization in multiple reaction monitoring mode. Precursor-to-product ion transitions were monitored at 266.100 to 234.100 for albendazole (ABZ), 282.200 to 208.100 for albendazole sulfoxide (ABZSO), 298.200 to 159.100 for albendazole sulfone (ABZSO2) and 240.200 to 133.100 for albendazole amino sulfone (ABZSO2-NH2). Calibration curves had good linearities with R2 of 0.9905–0.9972. Limits of quantitation (LOQs) were 1.32 ng/mL for ABZ, 16.67 ng/mL for ABZSO, 0.76 ng/mL for ABZSO2 and 5.94 ng/mL for ABZSO2-NH2. Recoveries were 93.12%–103.83% for ABZ, 66.51%–108.51% for ABZSO, 96.85%–105.6% for ABZSO2 and 96.46%–106.14% for ABZSO2-NH2, (RSDs <8%). Accuracy, precision and stability tests showed acceptable variation in quality control (QC) samples. This analytical method successfully determined albendazole and its metabolites in silkworm hemolymph in a pharmacokinetic study. The results of single-dose treatment suggested that the concentrations of ABZ, ABZSO and ABZSO2 increased and then fell, while ABZSO2-NH2 level was low without obvious change. Different trends were observed for multi-dose treatment, with concentrations of ABZSO and ABZSO2 rising over time. PMID:25255321

  9. Analysis of caged xanthones from the resin of Garcinia hanburyi using ultra-performance liquid chromatography/electrospray ionization quadrupole time-of-flight tandem mass spectrometry.

    Science.gov (United States)

    Zhou, Yan; Liu, Xin; Yang, Jing; Han, Quan-Bin; Song, Jing-Zheng; Li, Song-Lin; Qiao, Chun-Feng; Ding, Li-Sheng; Xu, Hong-Xi

    2008-11-23

    On-line ultra high-performance liquid chromatography (UHPLC) coupled with electrospray quadrupole time-of-flight tandem mass spectrometry (ESI-QTOF-MS/MS/MS) has been developed for the analysis of a series of caged xanthones in the resin of Garcinia hanburyi. The fragmentation of protonated molecular ions for 12 known cadged xanthones was carried out using low-energy collision-induced electrospray ionization tandem mass spectrometry. It was found that Retro-Diels-Alder rearrangement occurred in the CID processes and produced the characteristic fragment ions, which are especially valuable for the identification of this class of xanthones. The fragmentation differential between some cis-, trans-isomers was uncovered. Computation methods were utilized to rationalize the observed MS behaviors. On-line UHPLC-ESI-MS/MS/MS method has proved to be rapid and efficient in that within 6min, 15 caged scaffold xanthones, including three pairs of epimers and four pairs of isomers in gamboges, were effectively separated and identified. Among them, two known, namely isogambogenin (13) and isomorellinol (14) and one likely new caged Garcinia xanthones from the Garcinia hanburyi were tentatively characterized based on the tandem mass spectra of known ones.

  10. Analysis of caged xanthones from the resin of Garcinia hanburyi using ultra-performance liquid chromatography/electrospray ionization quadrupole time-of-flight tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zhou Yan [Hong Kong Jockey Club Institute of Chinese Medicine, Shatin, Hong Kong (China); Liu Xin [Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu 610041, Sichuan Province (China); Yang Jing [School of Chemistry and Chemical Technology, Shanghai Jiao Tong University, Shanghai 200240 (China); Han Quanbin; Song Jingzheng; Li Songlin; Qiao Chunfeng [Hong Kong Jockey Club Institute of Chinese Medicine, Shatin, Hong Kong (China); Ding Lisheng [Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu 610041, Sichuan Province (China)], E-mail: lsding@cib.ac.cn; Xu Hongxi [Hong Kong Jockey Club Institute of Chinese Medicine, Shatin, Hong Kong (China)], E-mail: xuhongxi@hkjcicm.org

    2008-11-23

    On-line ultra high-performance liquid chromatography (UHPLC) coupled with electrospray quadrupole time-of-flight tandem mass spectrometry (ESI-QTOF-MS/MS/MS) has been developed for the analysis of a series of caged xanthones in the resin of Garcinia hanburyi. The fragmentation of protonated molecular ions for 12 known cadged xanthones was carried out using low-energy collision-induced electrospray ionization tandem mass spectrometry. It was found that Retro-Diels-Alder rearrangement occurred in the CID processes and produced the characteristic fragment ions, which are especially valuable for the identification of this class of xanthones. The fragmentation differential between some cis-, trans-isomers was uncovered. Computation methods were utilized to rationalize the observed MS behaviors. On-line UHPLC-ESI-MS/MS/MS method has proved to be rapid and efficient in that within 6 min, 15 caged scaffold xanthones, including three pairs of epimers and four pairs of isomers in gamboges, were effectively separated and identified. Among them, two known, namely isogambogenin (13) and isomorellinol (14) and one likely new caged Garcinia xanthones from the Garcinia hanburyi were tentatively characterized based on the tandem mass spectra of known ones.

  11. Metabolomic profiling of Campylobacter jejuni with resistance gene ermB by ultra-high performance liquid chromatography-quadrupole time-of-flight mass spectrometry and tandem quadrupole mass spectrometry.

    Science.gov (United States)

    Fu, Qin; Liu, Dejun; Wang, Yingyu; Li, Xiaowei; Wang, Lina; Yu, Fugen; Shen, Jianzhong; Xia, Xi

    2018-03-15

    The metabolome changes of Campylobacter jejuni with resistant gene ermB remain unclear. Here, we described an untargeted metabolomic workflow based on ultra-high performance liquid chromatography-quadrupole time-of-flight mass spectrometry to investigate the metabolites perturbations mediated by ermB in C. jejuni. After optimization of extractants and chromatographic conditions, the combination of 100% methanol extraction with a 12 min gradient by C18 column was adopted for untargeted metabolomic profiling in reversed phase separation. Meanwhile, 60% methanol extraction followed by a 14 min separation using hydrophilic interaction chromatography column was suitable to complementally expand the metabolite coverage of C. jejuni. Multivariate statistical analysis was performed by means of orthogonal projection to latent structures-discriminant analysis to select metabolic features. The selected features were further confirmed by ultra-high performance liquid chromatography-tandem quadrupole mass spectrometry. A total of thirty-six differential metabolites between the susceptible strain (C. jejuni NCTC 11168) and resistant stain (C. jejuni NCTC 11168 with ermB) were identified. These pivotal metabolites were primarily participated in biological processes as cell signaling, membrane integrity/stability, fuel and energy source/storage and nutrient. The biofilm formation capability of resistant strain was inferior to that of susceptible strain, confirming the influence of ermB on membrane integrity/stability of C. jejuni. Our findings revealed important metabolic regulatory pathways associated with resistant C. jejuni with ermB. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Differentially pumped dual linear quadrupole ion trap mass spectrometer

    Science.gov (United States)

    Owen, Benjamin C.; Kenttamaa, Hilkka I.

    2015-10-20

    The present disclosure provides a new tandem mass spectrometer and methods of using the same for analyzing charged particles. The differentially pumped dual linear quadrupole ion trap mass spectrometer of the present disclose includes a combination of two linear quadrupole (LQIT) mass spectrometers with differentially pumped vacuum chambers.

  13. Ion trajectories quadrupole mass filters

    International Nuclear Information System (INIS)

    Ursu, D.; Lupsa, N.; Muntean, F.

    1994-01-01

    The present paper aims at bringing some contributions to the understanding of ion motion in quadrupole mass filters. The theoretical treatment of quadrupole mass filter is intended to be a concise derivation of the important physical relationships using Mathieu functions. A simple iterative method of numerical computation has been used to simulate ion trajectories in an ideal quadrupole field. Finally, some examples of calculation are presented with the aid of computer graphics. (Author) 14 Figs., 1 Tab., 20 Refs

  14. Simultaneous determination of 9 heterocyclic aromatic amines in pork products by liquid chromatography coupled with triple quadrupole tandem mass spectrometry

    Science.gov (United States)

    Shen, X. C.; Zhang, Y. L.; Cui, Y. Q.; Xu, L. Y.; Li, X.; Qi, J. H.

    2017-07-01

    Heterocyclic aromatic amines (HAAs) are potent mutagens that formed at high temperature in cooked, protein-rich food. Owing to their frequent intake, an accurate method is essential to access human health risk of HAAs exposure through detecting these compounds in various heat-treated meat products. In this study, a liquid chromatography-electrospray tandem mass spectrometry (LC--ESI-MS/MS) method was developed to perform the determination of 9 mutagenic heterocyclic amines (HAAs) in meat samples with multiple reaction monitoring (MRM) mode. Ultrasound assisted extraction and diatomaceous earth was employed to extract HAAs from food samples, and the analytes were purified and enriched using tandem solid phase extraction, with propyl sulfonic acid coupled to a C18 cartridge. Two parameters, extraction time and eluent, were carefully optimized to improve the extraction and purification efficiency. The LC separation was carried out using a Zorbax SB-C18 (3.5 μm particle size, 2.1 × 150 mm i.d.) column and optimized some parameters, such as pH, concentration and volume. Under the optimal experimental conditions, recoveries ranged from 52.97% to 97.11% with good quality parameters: limit of detection values between 0.02 and 0.24 ng mL-1, linearity (R2>0.998), and run-to-run and day-to-day precisions lower than 9.81% achieved. To evaluate the performance of the method in high throughput analysis of complex meat samples, the LC-MS/MS method was applied to the analysis of HAAs in three food samples, and the results demonstrated that the method can be used for the trace determination of HAAs in pork samples.

  15. Global chemical profiling based quality evaluation approach of rhubarb using ultra performance liquid chromatography with tandem quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Zhang, Li; Liu, Haiyu; Qin, Lingling; Zhang, Zhixin; Wang, Qing; Zhang, Qingqing; Lu, Zhiwei; Wei, Shengli; Gao, Xiaoyan; Tu, Pengfei

    2015-02-01

    A global chemical profiling based quality evaluation approach using ultra performance liquid chromatography with tandem quadrupole time-of-flight mass spectrometry was developed for the quality evaluation of three rhubarb species, including Rheum palmatum L., Rheum tanguticum Maxim. ex Balf., and Rheum officinale Baill. Considering that comprehensive detection of chemical components is crucial for the global profile, a systemic column performance evaluation method was developed. Based on this, a Cortecs column was used to acquire the chemical profile, and Chempattern software was employed to conduct similarity evaluation and hierarchical cluster analysis. The results showed R. tanguticum could be differentiated from R. palmatum and R. officinale at the similarity value 0.65, but R. palmatum and R. officinale could not be distinguished effectively. Therefore, a common pattern based on three rhubarb species was developed to conduct the quality evaluation, and the similarity value 0.50 was set as an appropriate threshold to control the quality of rhubarb. A total of 88 common peaks were identified by their accurate mass and fragmentation, and partially verified by reference standards. Through the verification, the newly developed method could be successfully used for evaluating the holistic quality of rhubarb. It would provide a reference for the quality control of other herbal medicines. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Structural Characterization of New Peptide Variants Produced by Cyanobacteria from the Brazilian Atlantic Coastal Forest Using Liquid Chromatography Coupled to Quadrupole Time-of-Flight Tandem Mass Spectrometry.

    Science.gov (United States)

    Sanz, Miriam; Andreote, Ana Paula Dini; Fiore, Marli Fatima; Dörr, Felipe Augusto; Pinto, Ernani

    2015-06-18

    Cyanobacteria from underexplored and extreme habitats are attracting increasing attention in the search for new bioactive substances. However, cyanobacterial communities from tropical and subtropical regions are still largely unknown, especially with respect to metabolite production. Among the structurally diverse secondary metabolites produced by these organisms, peptides are by far the most frequently described structures. In this work, liquid chromatography/electrospray ionization coupled to high resolution quadrupole time-of-flight tandem mass spectrometry with positive ion detection was applied to study the peptide profile of a group of cyanobacteria isolated from the Southeastern Brazilian coastal forest. A total of 38 peptides belonging to three different families (anabaenopeptins, aeruginosins, and cyanopeptolins) were detected in the extracts. Of the 38 peptides, 37 were detected here for the first time. New structural features were proposed based on mass accuracy data and isotopic patterns derived from full scan and MS/MS spectra. Interestingly, of the 40 surveyed strains only nine were confirmed to be peptide producers; all of these strains belonged to the order Nostocales (three Nostoc sp., two Desmonostoc sp. and four Brasilonema sp.).

  17. Identification of acteoside and its major metabolites in rat urine by ultra-performance liquid chromatography combined with electrospray ionization quadrupole time-of-flight tandem mass spectrometry.

    Science.gov (United States)

    Qi, Meng; Xiong, Aizhen; Li, Pengfei; Yang, Qiming; Yang, Li; Wang, Zhengtao

    2013-12-01

    In this study, metabolites in the urine samples of rats orally administered with acteoside, a phenylethanoid glycoside compound, were detected and identified using ultra-performance liquid chromatography coupled with electrospray ionization quadrupole time-of-flight tandem mass spectrometry (UPLC/ESI-QTOF-MS) combined with an automated MS(E) technique. Up to 35 metabolites (19 metabolites of the parent drug and 16 metabolites of the degradation products) were observed, including processes of oxidization, glucuronidation, sulfation, and methyl conjugation. According to the metabolic pathways, acteoside mainly functioned as a prodrug and underwent hydrolysis before being absorbed into the blood. The degradation products, especially caffeic acid and hydroxytyrosol, were involved in further metabolism which was responsible for the low oral bioavailability but obvious pharmacological activities of acteoside. In summary, this work provided valuable information on acteoside metabolism through the rapid and reliable UPLC/ESI-QTOF-MS technique, which could be widely used for the investigation of natural product metabolites. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Hydrophilic interaction ultra-performance liquid chromatography coupled with triple-quadrupole tandem mass spectrometry for highly rapid and sensitive analysis of underivatized amino acids in functional foods.

    Science.gov (United States)

    Zhou, Guisheng; Pang, Hanqing; Tang, Yuping; Yao, Xin; Mo, Xuan; Zhu, Shaoqing; Guo, Sheng; Qian, Dawei; Qian, Yefei; Su, Shulan; Zhang, Li; Jin, Chun; Qin, Yong; Duan, Jin-ao

    2013-05-01

    This work presented a new analytical methodology based on hydrophilic interaction ultra-performance liquid chromatography coupled with triple-quadrupole tandem mass spectrometry in multiple-reaction monitoring mode for analysis of 24 underivatized free amino acids (FAAs) in functional foods. The proposed method was first reported and validated by assessing the matrix effects, linearity, limit of detections and limit of quantifications, precision, repeatability, stability and recovery of all target compounds, and it was used to determine the nutritional substances of FAAs in ginkgo seeds and further elucidate the nutritional value of this functional food. The result showed that ginkgo seed turned out to be a good source of FAAs with high levels of several essential FAAs and to have a good nutritional value. Furthermore, the principal component analysis was performed to classify the ginkgo seed samples on the basis of 24 FAAs. As a result, the samples could be mainly clustered into three groups, which were similar to areas classification. Overall, the presented method would be useful for the investigation of amino acids in edible plants and agricultural products.

  19. The application of headspace gas chromatography coupled to tandem quadrupole mass spectrometry for the analysis of furan in baby food samples.

    Science.gov (United States)

    Pugajeva, Iveta; Rozentale, Irina; Viksna, Arturs; Bartkiene, Elena; Bartkevics, Vadims

    2016-12-01

    Selective methodology employing a tandem quadrupole mass spectrometer coupled to a gas chromatograph with headspace autosampler (HS-GC-MS/MS) was elaborated in this study. Application of the elaborated procedure resulted in a limit of detection of 0.021μgkg(-1) and a limit of quantification of 0.071μgkg(-1). The mean recoveries during in-house validation ranged from 89% to 109%, and coefficients of variation for repeatability ranged from 4% to 11%. The proposed analytical method was applied for monitoring the furan content of 30 commercial baby food samples available on the Latvian retail market. The level of furan found in these samples varied from 0.45 to 81.9μgkg(-1), indicating that infants whose sole diet comprises baby food sold in jars and cans are exposed constantly to furan. Samples containing vegetables and meat had higher levels of furan than those containing only fruits. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Rapid separation and identification of major constituents in Pseudolarix kaempferi by ultra-performance liquid chromatography coupled with electrospray and quadrupole time-of-flight tandem mass spectrometry.

    Science.gov (United States)

    Ye, Xia; Tang, Minghai; Chen, Lijuan; Peng, Aihua; Ma, Liang; Ye, Haoyu

    2009-12-01

    A rapid and reliable method based on ultra-performance liquid chromatography (UPLC) coupled with photodiode-array detection (PDA) and electrospray ionization quadrupole time-of-flight tandem mass spectrometry (ESI-Q-TOF-MS/MS) has been developed for separation and identification of major constituents in extracts of root bark of Pseudolarix kaempferi Gordon (PKG). Identification of the constituents was carried out by interpretation of their retention times, UV absorption spectra, MS and MS/MS spectra, as well as the data provided by authentic standards and literatures. A total of 20 components were separated in only 8.0 min on a small particle size C18 column (1.7 microm). These components included nine diterpene acids, seven glycosides and four triterpenoids, among which pseudolaric acid C-O-beta-D-glucopyranoside and pseudolaric acid C2-O-beta-D-glucopyranoside were separated and identified for the first time in this study. Furthermore, the fragmentation patterns of the three types of compounds were elucidated for the first time. This established UPLC-PDA/Q-TOF-MS/MS method is reliable and effective for the separation and identification of the 20 compounds and will be useful for quality control of the crude materials of Pseudolarix kaempferi Gordon and their related preparations. Copyright 2009 John Wiley & Sons, Ltd.

  1. Metabolism of Genipin in Rat and Identification of Metabolites by Using Ultraperformance Liquid Chromatography/Quadrupole Time-of-Flight Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Yue Ding

    2013-01-01

    Full Text Available The in vivo and in vitro metabolism of genipin was systematically investigated in the present study. Urine, plasma, feces, and bile were collected from rats after oral administration of genipin at a dose of 50 mg/kg body weight. A rapid and sensitive method using ultraperformance liquid chromatography coupled with electrospray ionization quadrupole time-of-flight tandem mass spectrometry (UPLC-Q/TOF MS was developed for analysis of metabolic profile of genipin in rat biological samples (urine, plasma, feces, and bile. A total of ten metabolites were detected and identified by comparing their fragmentation patterns with that of genipin using MetaboLynx software tools. On the basis of the chromatographic peak area, the sulfated and glucuronidated conjugates of genipin were identified as major metabolites. And the existence of major metabolites G1 and G2 was confirmed by the in vitro enzymatic study further. Then, metabolite G1 was isolated from rat bile by semipreparative HPLC. Its structure was unambiguously identified as genipin-1-o-glucuronic acid by comparison of its UV, IR, ESI-MS, 1H-NMR, and 13C-NMR spectra with conference. In general, genipin was a very active compound that would transform immediately, and the parent form of genipin could not be observed in rats biological samples. The biotransformation pathways of genipin involved demethylated, ring-opened, cysteine-conjugated, hydroformylated, glucuronidated, and sulfated transformations.

  2. Determination of gamithromycin in an injection by ultra-performance liquid chromatography-tandem quadrupole-time-of-flight mass spectrometry.

    Science.gov (United States)

    Wu, Jia-Xin; Zhang, Gang; Song, Min; Liu, Min; Liang, Jing-Le; Xu, Jin-Lei; Shang, Fei; Qi, Peng

    2016-07-07

    In this study, a sensitive and precise method was developed for the determination of gamithromycin in an injection using ultra-performance liquid chromatography-tandem quadrupole-time-of-flight mass spectrometry (UPLC-QTOF-MS) and the results were compared with a similar analysis for the ion fragments of gamithromycin in MS/ MS. The sample was dissolved in methanol then filtered and separated on a C18 column using acetonitrile-0.1% formic acid (containing 2 mmol/L ammonium acetate) as the mobile phase. The flow rate was 0.4 mL/min and the column temperature was 40 °C. The mass spectrometry conditions were electrospray ionization (ESI) operated in positive ion full scan mode and quantified using external calibration. Subsequently, ion fragments of the MS/MS were compared and analyzed. The linear range was 10 ∼ 200 μg/L with a correlation coefficient of 0.9992. The limit of detection (LOD) was 0.77 μg/L and the limit of quantitation (LOQ) was 2.55 μg/L. The average recoveries of the intra-assay were 98.8%-105.6% with a relative standard deviation ranging from 1.79% to 2.38% and the inter-assay were 89.3%-110.7% with a relative standard deviation ranging from 4.93% to 6.27%. After the comparative analysis of the fragments with a Molecular Structure Correlator, the score of the total matching degree reached 83.19 and the scores of each ion fragment matching degree were all greater than 90, which supplied the basis for the confirmation of gamithromycin. The results indicated that the method was simple, sensitive and precise and could be applied in the determination of gamithromycin in real samples.

  3. Comparison of solid phase microextraction and hollow fiber liquid phase microextraction for the determination of pesticides in aqueous samples by gas chromatography triple quadrupole tandem mass spectrometry.

    Science.gov (United States)

    Garrido Frenich, Antonia; Romero-González, R; Martínez Vidal, José Luis; Martínez Ocaña, R; Baquero Feria, P

    2011-02-01

    This work compares two miniaturised sample preparation methods, solid phase microextraction (SPME) and hollow fiber liquid phase microextraction (HF-LPME), in combination with gas chromatography coupled to tandem mass spectrometry with a triple quadrupole analyzer for the determination of 77 pesticides in drinking water. In the case of SPME, extraction temperature and time were optimized by experimental design, although other parameters, as desorption time, pH, and ionic strength, were also evaluated. The extraction and desorption solvents [octanol/dihexyl ether (75:25, v/v) and cyclohexane, respectively], as well as the extraction and desorption time, ionic strength, and pH, were studied for the HF-LPME procedure. Under the optimal conditions, recoveries (70.2-113.5% for SPME and 70.0-119.5% for HF-LPME), intra-day precision (2.1-19.4% for SPME and 4.3-22.5% for HF-LPME), inter-day precision (5.2-21.5% for SPME and 8.4-27.3% for HF-LPME), and limits of detection, between 0.1 and 28.8 ng/L for SPME and 0.2 and 47.1 ng/L for HF-LPME and overall uncertainty (9.6-25.2% for SPME and 13.3-27.5% for HF-LPME) were established for both extraction procedures. Finally, the proposed methods were successfully applied to the analysis of 41 drinking water samples, and similar results were obtained with both extraction approaches.

  4. Identification and characterization of vilazodone metabolites in rats and microsomes by ultrahigh-performance liquid chromatography/quadrupole time-of-flight tandem mass spectrometry.

    Science.gov (United States)

    Chavan, Balasaheb B; Kalariya, Pradipbhai D; Tiwari, Shristy; Nimbalkar, Rakesh D; Garg, Prabha; Srinivas, R; Talluri, M V N Kumar

    2017-12-15

    Vilazodone is a selective serotonin reuptake inhibitor (SSRI) used for the treatment of major depressive disorder (MDD). An extensive literature search found few reports on the in vivo and in vitro metabolism of vilazodone. Therefore, we report a comprehensive in vivo and in vitro metabolic identification and structural characterization of vilazodone using ultrahigh-performance liquid chromatography/quadrupole time-of-flight tandem mass spectrometry (UPLC/Q-TOF/MS/MS) and in silico toxicity study of the metabolites. To identify in vivo metabolites of vilazodone, blood, urine and faeces samples were collected at different time intervals starting from 0 h to 48 h after oral administration of vilazodone to Sprague-Dawley rats. The in vitro metabolism study was conducted with human liver microsomes (HLM) and rat liver microsomes (RLM). The samples were prepared using an optimized sample preparation approach involving protein precipitation followed by solid-phase extraction. The metabolites have been identified and characterized by using LC/ESI-MS/MS. A total of 12 metabolites (M1-M12) were identified in in vivo and in vitro matrices and characterized by LC/ESI-MS/MS. The majority of the metabolites were observed in urine, while a few metabolites were present in faeces and plasma. Two metabolites were observed in the in vitro study. A semi-quantitative study based on percentage counts shows that metabolites M11, M6 and M8 were observed in higher amounts in urine, faeces and plasma, respectively. The structures of all the 12 metabolites were elucidated by using LC/ESI-MS/MS. The study suggests that vilazodone was metabolized via hydroxylation, dihydroxylation, glucuronidation, oxidative deamination, dealkylation, dehydrogenation and dioxidation. All the metabolites were screened for toxicity using an in silico tool. Copyright © 2017 John Wiley & Sons, Ltd.

  5. Development of a multi-residue screening method for the determination of pesticides in cereals and dry animal feed using gas chromatography-triple quadrupole tandem mass spectrometry.

    Science.gov (United States)

    Walorczyk, Stanisław

    2007-09-21

    A multi-residue screening method for simultaneous analysis of 122 gas chromatography amenable pesticides in dry matrices such as cereal grain and certain feedingstuffs was developed. The method entails a simple extraction of re-hydrated sample with acetonitrile followed by a dispersive solid phase extraction (dispersive-SPE) clean-up step prior to the final determination by gas chromatography/triple quadrupole tandem mass spectrometry (GC-MS/MS). Due to complexity of analyzed matrices, two MS/MS transitions were set for each pesticide to eliminate the need for re-analysis of potentially positive samples, and provide unequivocal identification of detected pesticides in accordance with recent guidelines, in a single analytical run. Thus, in the developed GC-MS/MS acquisition method, a total of 216 different multiple reactions monitoring (MRM) transitions were monitored in one set of experimental conditions. To evaluate performance of the method, validation experiments were carried out on wheat grain at three spiking levels (0.01, 0.02 and 0.05 mg kg(-1)). Additional recovery tests at 0.05 mg kg(-1) were carried out on several other matrices. The recoveries ranged between 73 and 129% with associated relative standard deviations between 1 and 29% for the majority of pesticides. Limits of detection were less or equal to 0.01 mg kg(-1) for approximately 68% of pesticides. The applicability of the proposed method to detect and quantify pesticide residues has been demonstrated in the analysis of 136 real samples. Additionally, the method was favorably compared with an acetone extraction method (accepted as a reference method by some of European and U.S. authorities) in the analysis of real samples known to contain pesticide residues.

  6. Analysis of 44 drugs of abuse and metabolites in wastewater and river water using a hybrid quadrupole time-of-flight tandem mass spectrometry

    Science.gov (United States)

    Andres-Costa, M. Jesus; Andreu, Vicente; Picó, Yolanda

    2016-04-01

    The presence of drugs of abuse in the aquatic environment has been recognized as an important issue for the ecosystem due their possible negative effect on it (Richardson, 2011). Incomplete removal of these substances during wastewater treatment could be one of the causes of their release in the environment (Zuccato and Castiglioni, 2009). Pollution by illicit drug residues at very low concentrations is generalized in populated areas, with potential risks for human health and the environment (Zuccato, 2008; Castiglioni et al 2007).The aim of this study was to screen and quantify 44 drugs of abuse and metabolites of wastewater samples using a hybrid quadrupole time-of-flight tandem mass spectrometry and furthermore carry out a post-target screening to identify additional compounds present in the water samples. Wastewater samples were collected from the influent and effluent of three wastewater treatment plants (WWTPs) in Valencia and river water samples form Turia River Basin. Illicit drugs were extracted by solid-phase extraction (SPE). The chromatography was performed with an Agilent 1260 Infinity ultra high performance liquid chromatography (UHPLC). The UHPLC system was coupled to a hybrid quadrupole time-of-flight ABSciex Triple TOFTM 5600. All analytes were analyzed in positive mode. Acquiring full scan MS data was employed for quantification of drugs of abuse, and automatic data dependent information product ion spectra (IDA-MS/MS) was checked for identifying emerging illicit drugs and other compounds in water samples. The use of a database containing 1212 compounds achieved high confidence results for a wide number of contaminants. In the present study, the presence of compounds that belong to amphetamines group (amphetamine, methamphetamine, ephedrine, MDMA, MDA and MDEA), tryptamines (bufotenine), pirrolidinophenone group (α-PVP and 4'-MePHP), arylcyclohexylamines (ketamine), cocainics (cocaine, benzoylecgonine, cocaethylene and ecgonine methyl ester) and

  7. Determination of volatile organic compounds in water by headspace solid-phase microextraction gas chromatography coupled to tandem mass spectrometry with triple quadrupole analyzer

    Energy Technology Data Exchange (ETDEWEB)

    Cervera, M.I. [Research Institute for Pesticides and Water, University Jaume I, Avda. Sos Baynat, E-12071 Castellon (Spain); Beltran, J., E-mail: joaquim.beltran@uji.es [Research Institute for Pesticides and Water, University Jaume I, Avda. Sos Baynat, E-12071 Castellon (Spain); Lopez, F.J.; Hernandez, F. [Research Institute for Pesticides and Water, University Jaume I, Avda. Sos Baynat, E-12071 Castellon (Spain)

    2011-10-17

    Highlights: {yields} Employing a statistical optimization improves results reducing experiments. {yields} Use of MS (QqQ) allows high sensitivity determination and improves identification capabilities. {yields} Using Q/q intensity ratios is a powerful tool to ensure compound identification. {yields} HS SPME GC-MS/MS method allows determination of VOCs in complex matrix water samples. - Abstract: In the present work, a rapid method with little sample handling has been developed for determination of 23 selected volatile organic compounds in environmental and wastewater samples. The method is based on headspace solid-phase microextraction (SPME) followed by gas chromatography coupled to tandem mass spectrometry (GC-MS/MS) determination using triple quadrupole analyzer (QqQ) in electron ionization mode. The best conditions for extraction were optimised with a factorial design taking into account the interaction between different parameters and not only individual effects of variables. In the optimized procedure, 4 mL of water sample were extracted using a 10 mL vial and adding 0.4 g NaCl (final NaCl content of 10%). An SPME extraction with carboxen/polydimethylsiloxane 75 {mu}m fiber for 30 min at 50 deg. C (with 5 min of previous equilibration time) with magnetic stirring was applied. Chromatographic determination was carried out by GC-MS/MS working in Selected Reaction Monitoring (SRM) mode. For most analytes, two MS/MS transitions were acquired, although for a few compounds it was difficult to obtain characteristic abundant fragments. In those cases, a pseudo selected reaction monitoring (pseudo-SRM) with three ions was used instead. The intensity ratio between quantitation (Q) and confirmation (q) signals was used as a confirmatory parameter. The method was validated by means of recovery experiments (n = 6) spiking mineral water samples at three concentration levels (0.1, 5 and 50 {mu}g L{sup -1}). Recoveries between 70% and 120% were generally obtained with

  8. Optimized Fast and Sensitive Acquisition Methods for Shotgun Proteomics on a Quadrupole Orbitrap Mass Spectrometer

    DEFF Research Database (Denmark)

    Kelstrup, Christian D; Young, Clifford; Lavallee, Richard

    2012-01-01

    Advances in proteomics are continually driven by the introduction of new mass spectrometric instrumentation with improved performances. The recently introduced quadrupole Orbitrap (Q Exactive) tandem mass spectrometer allows fast acquisition of high-resolution higher-energy collisional dissociation...

  9. Quadrupole Time-of-Flight Mass Spectrometer

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: The system generates superior quality mass spectrometry (MS) and tandem mass spectrometry (MS/MS) data from both atmospheric pressure ionization (API) and...

  10. Multi-residue method for the determination of organochlorine pesticides in fish feed based on a cleanup approach followed by gas chromatography-triple quadrupole tandem mass spectrometry.

    Science.gov (United States)

    Nardelli, Valeria; dell'Oro, Daniela; Palermo, Carmen; Centonze, Diego

    2010-07-23

    A multi-residue method for the determination of organochlorine pesticides in fish feed samples was developed and optimized. The method is based on a cleanup step of the extracted fat, carried out by liquid-liquid extraction on diatomaceous earth cartridge with n-hexane/acetonitrile (80/20, v/v) followed by solid phase extraction (SPE) with silica gel-SCX cartridge, before the identification and quantification of the residues by gas chromatography-triple quadrupole tandem spectrometry (GC-MS/MS). Performance characteristics, such as accuracy, precision, linear range, limits of detection (LOD) and quantification (LOQ), for each pesticide were determined. Instrumental LODs ranged from 0.01 to 0.11 microg L(-1), LOQs were in the range of 0.02-0.35 microg L(-1), and calibration curves were linear (r2>0.999) in the whole range of explored concentrations (5-100 microg L(-1)). Repeatability values were in the range of 3-15%, evaluated from the relative standard deviation of six samples spiked at 100 microg kg(-1) of fat, and in compliance with that derived by the Horwitz's equation. No matrix effects or interfering substances were observed in fish feed analyses. The proposed method allowed high recoveries (92-116%) of spiked extracted fat samples at 100 microg kg(-1), and very low LODs (between 0.02 and 0.63 microg kg(-1)) and LOQs (between 0.05 and 2.09 microg kg(-1)) determined in fish feed samples. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  11. Mechanism of Formation of the Major Estradiol Product Ions Following Collisional Activation of the Molecular Anion in a Tandem Quadrupole Mass Spectrometer

    Science.gov (United States)

    Wooding, Kerry M.; Barkley, Robert M.; Hankin, Joseph A.; Johnson, Christopher A.; Bradford, Andrew P.; Santoro, Nanette; Murphy, Robert C.

    2013-01-01

    The importance of the mass spectral product ion structure is highlighted in quantitative assays, which typically use MRM (multiple reaction monitoring), and in the discovery of novel metabolites. Estradiol is an important sex steroid whose quantitation and metabolite identification using tandem mass spectrometry has been widely employed in numerous clinical studies. Negative electrospray ionization tandem mass spectrometry of estradiol (E2) results in several product ions, including the abundant m/z 183 and m/z 169. While m/z 183 is one of the most abundant product ions used in many quantitative assays, the structure of m/z 183 has not been rigorously examined. We suggest a structure for m/z 183 and a mechanism of formation consistent with collision induced dissociation (CID) of E2 and several stable isotopes ([D4]-E2, [13C6]-E2, and [D1]-E2). An additional product ion from E2, namely m/z 169, has also been examined. MS3 experiments indicated that both m/z 183 and m/z 169 originate from only E2 [M-H]− m/z 271. These ions, m/z 183 and m/z 169, were also present in the collision induced decomposition mass spectra of other prominent estrogens, estrone (E1) and estriol (E3), indicating that these two product ions could be used to elucidate the estrogenic origin of novel metabolites. We propose two fragmentation schemes to explain the CID data and suggested a structure of m/z 183 and m/z 169 consistent with several isotopic variants and high resolution mass spectrometric measurements. PMID:23955001

  12. Quantification of urinary 0,0'-dityrosine, a biomarker for oxidative damage to proteins, by high performance liquid chromatography with triple quadrupole tandem mas spectrometry. A comparison with ion-trap tandem mass spectrometry.

    NARCIS (Netherlands)

    Orhan, H.; Coolen, S.; Meerman, J.H.N.

    2005-01-01

    We recently described an isotope dilution reversed-phase liquid chromatography-atmospheric pressure chemical ionization-ion-trap-tandem mass spectrometry (HPLC-APCI-MS/MS) method for the quantitative determination of oxidized amino acids in human urine, including o,o′-dityrosine, a specific marker

  13. Tandem mass spectrometry at low kinetic energy

    International Nuclear Information System (INIS)

    Cooks, R.G.; Hand, O.W.

    1987-01-01

    Recent progress in mass spectrometry, as applied to molecular analysis, is reviewed with emphasis on tandem mass spectrometry. Tandem instruments use multiple analyzers (sector magnets, quadrupole mass filters and time-of-flight devices) to select particular molecules in ionic form, react them in the gas-phase and then record the mass, momenta or kinetic energies of their products. The capabilities of tandem mass spectrometry for identification of individual molecules or particular classes of compounds in complex mixtures are illustrated. Several different types of experiments can be run using a tandem mass spectrometer; all share the feature of sifting the molecular mixture being analyzed on the basis of chemical properties expressed in terms of ionic mass, kinetic energy or charge state. Applications of mass spectrometry to biological problems often depend upon desorption methods of ionization in which samples are bombarded with particle beams. Evaporation of preformed charged species from the condensed phase into the vacuum is a particularly effective method of ionization. It is suggested that the use of accelerator mass spectrometers be extended to include problems of molecular analysis. In such experiments, low energy tandem mass spectrometry conducted in the eV or keV range of energies, would be followed by further characterization of the production ion beam using high selective MeV collision processes

  14. Application of high-performance liquid chromatography-tandem mass spectrometry with a quadrupole/linear ion trap instrument for the analysis of pesticide residues in olive oil.

    Science.gov (United States)

    Hernando, M D; Ferrer, C; Ulaszewska, M; García-Reyes, J F; Molina-Díaz, A; Fernández-Alba, A R

    2007-11-01

    This article describes the development of an enhanced liquid chromatography-mass spectrometry (LC-MS) method for the analysis of pesticides in olive oil. One hundred pesticides belonging to different classes and that are currently used in agriculture have been included in this method. The LC-MS method was developed using a hybrid quadrupole/linear ion trap (QqQ(LIT)) analyzer. Key features of this technique are the rapid scan acquisition times, high specificity and high sensitivity it enables when the multiple reaction monitoring (MRM) mode or the linear ion-trap operational mode is employed. The application of 5 ms dwell times using a linearly accelerating (LINAC) high-pressure collision cell enabled the analysis of a high number of pesticides, with enough data points acquired for optimal peak definition in MRM operation mode and for satisfactory quantitative determinations to be made. The method quantifies over a linear dynamic range of LOQs (0.03-10 microg kg(-1)) up to 500 microg kg(-1). Matrix effects were evaluated by comparing the slopes of matrix-matched and solvent-based calibration curves. Weak suppression or enhancement of signals was observed (ion (EPI) and MS3 were developed.

  15. Quantitative analysis of the major constituents in Chinese medicinal preparation SuoQuan formulae by ultra fast high performance liquid chromatography/quadrupole tandem mass spectrometry.

    Science.gov (United States)

    Chen, Feng; Li, Hai-Long; Li, Yong-Hui; Tan, Yin-Feng; Zhang, Jun-Qing

    2013-07-30

    The SuoQuan formulae containing Fructus Alpiniae Oxyphyllae has been used to combat the urinary incontinence symptoms including frequency, urgency and nocturia for hundreds of years in China. However, the chemical information was not well characterized. The quality control marker constituent only focused on one single compound in the current Chinese Pharmacopeia. Hence it is prudent to identify and quantify the main constituents in this herbal product. This study aimed to analyze the main constituents using ultra-fast performance liquid chromatography coupled to tandem mass spectrometry (UFLC-MS/MS). Fourteen phytochemicals originated from five chemical classes constituents were identified by comparing the molecular mass, fragmentation pattern and retention time with those of the reference standards. A newly developed UFLC-MS/MS was validated demonstrating that the new assay was valid, reproducible and reliable. This method was successfully applied to simultaneously quantify the fourteen phytochemicals. Notably, the content of these constituents showed significant differences in three pharmaceutical preparations. The major constituent originated from each of chemical class was isolinderalactone, norisoboldine, nootkatone, yakuchinone A and apigenin-4',7-dimethylther, respectively. The variation among these compounds was more than 1000 times. Furthermore, the significant content variation between the two different Suoquan pills was also observed. The proposed method is sensitive and reliable; hence it can be used to analyze a variety of SuoQuan formulae products produced by different pharmaceutical manufacturers.

  16. Multi-residue analysis of legacy POPs and emerging organic contaminants in Singapore's coastal waters using gas chromatography-triple quadrupole tandem mass spectrometry.

    Science.gov (United States)

    Zhang, Hui; Bayen, Stéphane; Kelly, Barry C

    2015-08-01

    A gas chromatography-triple quadrupole mass spectrometry (GC-MS/MS) based method was developed for determination of 86 hydrophobic organic compounds in seawater. Solid-phase extraction (SPE) was employed for sequestration of target analytes in the dissolved phase. Ultrasound assisted extraction (UAE) and florisil chromatography were utilized for determination of concentrations in suspended sediments (particulate phase). The target compounds included multi-class hydrophobic contaminants with a wide range of physical-chemical properties. This list includes several polycyclic and nitro-aromatic musks, brominated and chlorinated flame retardants, methyl triclosan, chlorobenzenes, organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs). Spiked MilliQ water and seawater samples were used to evaluate the method performance. Analyte recoveries were generally good, with the exception of some of the more volatile target analytes (chlorobenzenes and bromobenzenes). The method is very sensitive, with method detection limits typically in the low parts per quadrillion (ppq) range. Analysis of 51 field-collected seawater samples (dissolved and particulate-bound phases) from four distinct coastal sites around Singapore showed trace detection of several polychlorinated biphenyl congeners and other legacy POPs, as well as several current-use emerging organic contaminants (EOCs). Polycyclic and nitro-aromatic musks, bromobenzenes, dechlorane plus isomers (syn-DP, anti-DP) and methyl triclosan were frequently detected at appreciable levels (2-20,000pgL(-1)). The observed concentrations of the monitored contaminants in Singapore's marine environment were generally comparable to previously reported levels in other coastal marine systems. To our knowledge, these are the first measurements of these emerging contaminants of concern in Singapore or Southeast Asia. The developed method may prove beneficial for future environmental monitoring of hydrophobic organic contaminants

  17. A Tandem-electrostatic-quadrupole for accelerator-based BNCT

    International Nuclear Information System (INIS)

    Kreiner, A.J.; Kwan, J.W.; Burlon, A.A.; Di Paolo, H.; Henestroza, E.; Minsky, D.M.; Valda, A.A.; Debray, M.E.; Somacal, H.

    2007-01-01

    A project to develop a Tandem-electrostatic-quadrupole (TESQ) accelerator for accelerator-based boron neutron capture therapy (AB-BNCT) is described. A folded Tandem, with 1.25 MV terminal voltage, combined with an electrostatic quadrupole (ESQ) chain is being proposed. The project goal is a machine capable of delivering 30 mA of 2.5 MeV protons to be used in conjunction with a neutron production target based on the 7 Li(p, n) 7 Be reaction slightly beyond its resonance at 2.25 MeV. This machine is conceptually shown to be capable of accelerating a 30 mA proton beam to 2.5 MeV. These are the specifications needed to produce sufficiently intense and clean epithermal neutron beams, based on the 7 Li(p, n) 7 Be reaction, to perform BNCT treatment for deep-seated tumors in less than an hour. This electrostatic machine is the technologically simplest and cheapest solution for optimized AB-BNCT

  18. Determination of non-halogenated, chlorinated and brominated organophosphate flame retardants in herring gull eggs based on liquid chromatography-tandem quadrupole mass spectrometry.

    Science.gov (United States)

    Chen, Da; Letcher, Robert J; Chu, Shaogang

    2012-01-13

    Numerous triester organophosphate flame retardants (OPFRs) have been used for several decades and continue to be used in a variety of commercial products. We developed a sensitive quantitative method for the analysis of, seven non-halogenated, three chlorinated and two brominated OPFRs of known or possible environmental relevance in herring gull eggs. This method is based on a simple two-step sample extraction followed by liquid chromatography-electrospray ionization(+)-tandem mass spectrometry. Instrumental detection limits and method limits of quantification (MLOQs) among the 12 OPFRs ranged from 0.01 to 0.12 ng/mL and 0.06 to 0.20 ng/g, respectively. The mean OPFR recovery efficiencies of replicate analyses (n=6) were very quantitative and ranged from 89% to 104%, with the two brominated OPFRs being somewhat lower but reproducible, i.e., 67% and 72%, respectively. Essentially negligible matrix effects were indicated by a standard addition approach that revealed mean percent signal recoveries (n=5 replicates) of 89-106% for most OPFRs. In the analysis of n=13 herring gull eggs from the Channel-Shelter Island colony (Lake Huron), tris(2-chloroisopropyl) phosphate (

  19. Rapid analysis of multiclass antibiotic residues and some of their metabolites in hospital, urban wastewater and river water by ultra-high-performance liquid chromatography coupled to quadrupole-linear ion trap tandem mass spectrometry.

    Science.gov (United States)

    Gros, Meritxell; Rodríguez-Mozaz, Sara; Barceló, Damià

    2013-05-31

    The present work describes the development of a fast and robust analytical method for the determination of 53 antibiotic residues, covering various chemical groups and some of their metabolites, in environmental matrices that are considered important sources of antibiotic pollution, namely hospital and urban wastewaters, as well as in river waters. The method is based on automated off-line solid phase extraction (SPE) followed by ultra-high-performance liquid chromatography coupled to quadrupole linear ion trap tandem mass spectrometry (UHPLC-QqLIT). For unequivocal identification and confirmation, and in order to fulfill EU guidelines, two selected reaction monitoring (SRM) transitions per compound are monitored (the most intense one is used for quantification and the second one for confirmation). Quantification of target antibiotics is performed by the internal standard approach, using one isotopically labeled compound for each chemical group, in order to correct matrix effects. The main advantages of the method are automation and speed-up of sample preparation, by the reduction of extraction volumes for all matrices, the fast separation of a wide spectrum of antibiotics by using ultra-high-performance liquid chromatography, its sensitivity (limits of detection in the low ng/L range) and selectivity (due to the use of tandem mass spectrometry) The inclusion of β-lactam antibiotics (penicillins and cephalosporins), which are compounds difficult to analyze in multi-residue methods due to their instability in water matrices, and some antibiotics metabolites are other important benefits of the method developed. As part of the validation procedure, the method developed was applied to the analysis of antibiotics residues in hospital, urban influent and effluent wastewaters as well as in river water samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Chemical profiling of Re-Du-Ning injection by ultra-performance liquid chromatography coupled with electrospray ionization tandem quadrupole time-of-flight mass spectrometry through the screening of diagnostic Ions in MS(E mode.

    Directory of Open Access Journals (Sweden)

    Haibo Li

    Full Text Available The broad applications and mechanism explorations of traditional Chinese medicine prescriptions (TCMPs require a clear understanding of TCMP chemical constituents. In the present study, we describe an efficient and universally applicable analytical approach based on ultra-performance liquid chromatography coupled to electrospray ionization tandem quadrupole time-of-flight mass spectrometry (UPLC-ESI-Q/TOF-MS with the MS(E ((E denotes collision energy data acquisition mode, which allowed the rapid separation and reliable determination of TCMP chemical constituents. By monitoring diagnostic ions in the high energy function of MS(E, target peaks of analogous compounds in TCMPs could be rapidly screened and identified. "Re-Du-Ning" injection (RDN, a eutherapeutic traditional Chinese medicine injection (TCMI that has been widely used to reduce fever caused by viral infections in clinical practice, was studied as an example. In total, 90 compounds, including five new iridoids and one new sesquiterpene, were identified or tentatively characterized by accurate mass measurements within 5 ppm error. This analysis was accompanied by MS fragmentation and reference standard comparison analyses. Furthermore, the herbal sources of these compounds were unambiguously confirmed by comparing the extracted ion chromatograms (EICs of RDN and ingredient herbal extracts. Our work provides a certain foundation for further studies of RDN. Moreover, the analytical approach developed herein has proven to be generally applicable for profiling the chemical constituents in TCMPs and other complicated mixtures.

  1. Accurate determination of 3-alkyl-2-methoxypyrazines in wines by gas chromatography quadrupole time-of-flight tandem mass spectrometry following solid-phase extraction and dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Fontana, Ariel; Rodríguez, Isaac; Cela, Rafael

    2017-09-15

    A new reliable method for the determination 3-alkyl-2-methoxypyrazines (MPs) in wine samples based on the sequential combination of solid-phase extraction (SPE), dispersive liquid-liquid microextraction (DLLME) and gas chromatography (GC) quadrupole time-of-flight accurate tandem mass spectrometry (QTOF-MS/MS) is presented. Primary extraction of target analytes was carried out by using a reversed-phase Oasis HLB (200mg) SPE cartridge combined with acetonitrile as elution solvent. Afterwards, the SPE extract was submitted to DLLME concentration using 0.06mL carbon tetrachloride (CCl 4 ) as extractant. Under final working conditions, sample concentration factors above 379 times and limits of quantification (LOQs) between 0.3 and 2.1ngL -1 were achieved. Moreover, the overall extraction efficiency of the method was unaffected by the particular characteristics of each wine; thus, accurate results (relative recoveries from 84 to 108% for samples spiked at concentrations from 5 to 25ngL -1 ) were obtained using matrix-matched standards, without using standard additions over every sample. Highly selective chromatographic records were achieved considering a mass window of 5mDa, centered in the quantification product ion corresponding to each compound. Twelve commercial wines, elaborated with grapes from different varieties and geographical origins, were processed with the optimized method. The 2-isobutyl-3-methoxypyrazine (IBMP) was determined at levels above the LOQs of the method in half of the samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Chemical Profiling of Re-Du-Ning Injection by Ultra-Performance Liquid Chromatography Coupled with Electrospray Ionization Tandem Quadrupole Time-of-Flight Mass Spectrometry through the Screening of Diagnostic Ions in MSE Mode

    Science.gov (United States)

    Wang, Zhenzhong; Geng, Jianliang; Dai, Yi; Xiao, Wei; Yao, Xinsheng

    2015-01-01

    The broad applications and mechanism explorations of traditional Chinese medicine prescriptions (TCMPs) require a clear understanding of TCMP chemical constituents. In the present study, we describe an efficient and universally applicable analytical approach based on ultra-performance liquid chromatography coupled to electrospray ionization tandem quadrupole time-of-flight mass spectrometry (UPLC-ESI-Q/TOF-MS) with the MSE (E denotes collision energy) data acquisition mode, which allowed the rapid separation and reliable determination of TCMP chemical constituents. By monitoring diagnostic ions in the high energy function of MSE, target peaks of analogous compounds in TCMPs could be rapidly screened and identified. “Re-Du-Ning” injection (RDN), a eutherapeutic traditional Chinese medicine injection (TCMI) that has been widely used to reduce fever caused by viral infections in clinical practice, was studied as an example. In total, 90 compounds, including five new iridoids and one new sesquiterpene, were identified or tentatively characterized by accurate mass measurements within 5 ppm error. This analysis was accompanied by MS fragmentation and reference standard comparison analyses. Furthermore, the herbal sources of these compounds were unambiguously confirmed by comparing the extracted ion chromatograms (EICs) of RDN and ingredient herbal extracts. Our work provides a certain foundation for further studies of RDN. Moreover, the analytical approach developed herein has proven to be generally applicable for profiling the chemical constituents in TCMPs and other complicated mixtures. PMID:25875968

  3. Fast throughput determination of 21 allergenic disperse dyes from river water using reusable three-dimensional interconnected magnetic chemically modified graphene oxide followed by liquid chromatography-tandem quadrupole mass spectrometry.

    Science.gov (United States)

    Zhao, Yong-Gang; Li, Xiao-Ping; Yao, Shan-Shan; Zhan, Ping-Ping; Liu, Jun-Chao; Xu, Chang-Ping; Lu, Yi-Yu; Chen, Xiao-Hong; Jin, Mi-Cong

    2016-01-29

    We report the template-free fabrication of three-dimensional hierarchical nanostructures, i.e., three-dimensional interconnected magnetic chemically modified graphene oxide (3D-Mag-CMGO), through a simple and low-cost self-assembly process using one-pot reaction based on solvothermal method. The excellent properties of the 3D-Mag-CMGO are characterized by transmission electron microscopy (TEM), scanning electron microscopy (SEM), vibrating sample magnetometer (VSM), FTIR, elementary analyzer (EA) and X-ray photoelectron spectroscopy (XPS). The easiness-to-handle of the magnetic dispersive solid phase extraction (Mag-dSPE) procedure is developed for preconcentration of 21 allergenic disperse dyes from river water. The obtained results show the higher extraction capacity of 3D-Mag-CMGO with recoveries between 80.0-112.0%. Furthermore, an ultra-fast liquid chromatography-tandem quadrupole mass spectrometry (UFLC-MS/MS) method for determination of 21 allergenic disperse dyes in river at sub-ppt levels has been developed with pretreatment of the samples by Mag-dSPE. The limits of quantification (LOQs) for the allergenic disperse dyes are between 0.57-34.05ng/L. Validation results on linearity, specificity, trueness and precision, as well as on application to the analysis of 21 allergenic disperse dyes in fifty real samples demonstrate the applicability to environment monitoring analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Chemometrics for comprehensive analysis of nucleobases, nucleosides, and nucleotides in Siraitiae Fructus by hydrophilic interaction ultra high performance liquid chromatography coupled with triple-quadrupole linear ion-trap tandem mass spectrometry.

    Science.gov (United States)

    Zhou, Guisheng; Wang, Mengyue; Xu, Renjie; Li, Xiao-Bo

    2015-10-01

    A rapid and sensitive hydrophilic interaction ultra high performance liquid chromatography coupled with triple-quadrupole linear ion-trap tandem mass spectrometry method was validated for the simultaneous determination of 20 nucleobases, nucleosides, and nucleotides (within 3.5 min), and then was employed to test the functional food of Luo-Han-Guo samples. The analysis showed that the Luo-Han-Guo was rich in guanosine and uridine, but contained trace levels of the other target compounds. Chemometrics methods were employed to identify 40 batches of Luo-Han-Guo samples from different cultivated forms, regions and varieties. Unsupervised hierarchical cluster analysis and principal component analysis were used to classify Luo-Han-Guo samples based on the level of the 20 target compounds, and the supervised learning method of counter propagation artificial neural network was utilized to further separate clusters and validate the established model. As a result, the samples could be clustered into three primary groups, in which correlation with cultivated varieties was observed. The present strategy could be applied to the investigation of other edible plants containing nucleobases, nucleosides, or nucleotides. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Applicability of Gas Chromatography (GC) Coupled to Triple-Quadrupole (QqQ) Tandem Mass Spectrometry (MS/MS) for Polybrominated Diphenyl Ether (PBDE) and Emerging Brominated Flame Retardant (BFR) Determinations in Functional Foods Enriched in Omega-3.

    Science.gov (United States)

    García-Bermejo, Ángel; Mohr, Susana; Herrero, Laura; González, María-José; Gómara, Belén

    2016-09-28

    This paper reports on the optimization, characterization, and applicability of gas chromatography coupled to triple-quadrupole tandem mass spectrometry (GC-QqQ(MS/MS)) for the determination of 14 polybrominated diphenylethers (PBDEs) and 2 emerging brominated flame retardants, 1,2-bis(2,4,6-tribromophenoxy)ethane (BTBPE) and decabromodiphenylethane (DBDPE), in functional food samples. The method showed satisfactory precision and linearity with instrumental limits of detection (iLODs) ranging from 0.12 to 7.1 pg, for tri- to octa-BDEs and BTBPE, and equal to 51 and 20 pg for BDE-209 and DBDPE, respectively. The highest ΣBFR concentrations were found in fish oil supplements (924 pg/g fresh weight, fw), followed by biscuits (90 pg/g fw), vegetable oil supplements (46 pg/g fw), chicken eggs (45 pg/g fw), cow's milk (7.7 pg/g fw), and soy products (1.6 pg/g fw). BDE-47, BDE-99, and DBDPE were the most abundant compounds. Foodstuffs enriched with omega-3 presented concentrations similar to or even lower than those of conventional foods commercialized in Spain since 2000.

  6. Determination of sulfonamide antibiotics and metabolites in liver, muscle and kidney samples by pressurized liquid extraction or ultrasound-assisted extraction followed by liquid chromatography-quadrupole linear ion trap-tandem mass spectrometry (HPLC-QqLIT-MS/MS).

    Science.gov (United States)

    Hoff, Rodrigo Barcellos; Pizzolato, Tânia Mara; Peralba, Maria do Carmo Ruaro; Díaz-Cruz, M Silvia; Barceló, Damià

    2015-03-01

    Sulfonamides are widely used in human and veterinary medicine. The presence of sulfonamides residues in food is an issue of great concern. Throughout the present work, a method for the targeted analysis of 16 sulfonamides and metabolites residue in liver of several species has been developed and validated. Extraction and clean-up has been statistically optimized using central composite design experiments. Two extraction methods have been developed, validated and compared: i) pressurized liquid extraction, in which samples were defatted with hexane and subsequently extracted with acetonitrile and ii) ultrasound-assisted extraction with acetonitrile and further liquid-liquid extraction with hexane. Extracts have been analyzed by liquid chromatography-quadrupole linear ion trap-tandem mass spectrometry. Validation procedure has been based on the Commission Decision 2002/657/EC and included the assessment of parameters such as decision limit (CCα), detection capability (CCβ), sensitivity, selectivity, accuracy and precision. Method׳s performance has been satisfactory, with CCα values within the range of 111.2-161.4 µg kg(-1), limits of detection of 10 µg kg(-1) and accuracy values around 100% for all compounds. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Direct analysis of 18 flavonol glycosides, aglycones and terpene trilactones in Ginkgo biloba tablets by matrix solid phase dispersion coupled with ultra-high performance liquid chromatography tandem triple quadrupole mass spectrometry.

    Science.gov (United States)

    Liu, Xin-Guang; Yang, Hua; Cheng, Xiao-Lan; Liu, Lei; Qin, Yong; Wang, Qi; Qi, Lian-Wen; Li, Ping

    2014-08-01

    Analysis and quality control of Ginkgo biloba have been comprehensively studied. However, little attention has been devoted to the simultaneous extraction and analysis of flavonols and terpene trilactones, especially for direct quantification of flavonol glycosides. This work described a rapid strategy for one-step extraction and quantification of the components. A matrix solid phase dispersion (MSPD) method was designed for the extraction of ginkgo ingredients and compared with the heat-reflux and ultrasonic extraction methods. An ultra-high performance liquid chromatography (UHPLC)-tandem-triple-quadrupole-mass spectrometry (QQQ-MS) method was developed for detection of the 18 components, including 10 original flavonol glycosides, 3 aglycones, and 5 lactones. Subsequently, the proposed strategy was used for the analysis of 12 G. biloba tablets. Results showed that MSPD produced comparable extraction efficiency but consumed less time and required lower solvent volumes compared with conventional methods. Without hydrolysis, the concentration detected was much closer to the original in the sample. The total flavonol glycoside contents in ginkgo tablets ranged from 3.59 to 125.21μgmg(-1), and the terpene trilactone varied from 3.45 to 57.8μgmg(-1) among different manufacturers. In conclusion, the proposed MSPD and UHPLC-QQQ-MS is rapid and sensitive in providing comprehensive profile of chemical constituents especially the genuine flavonol glycosides for improved quality control of ginkgo products. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Application of characteristic ion filtering with ultra-high performance liquid chromatography quadrupole time of flight tandem mass spectrometry for rapid detection and identification of chemical profiling in Eucommia ulmoides Oliv.

    Science.gov (United States)

    He, Mingzhen; Jia, Jia; Li, Junmao; Wu, Bei; Huang, Wenping; Liu, Mi; Li, Yan; Yang, Shilin; Ouyang, Hui; Feng, Yulin

    2018-04-17

    Efficient targeted identification of chemical constituents from traditional Chinese medicine is still a major challenge. In this study, we used a characteristic ion filtering strategy to characterize compounds of Eucommia ulmoides Oliv. by ultra-high performance liquid chromatography quadrupole time of flight tandem mass spectrometry (UHPLC-ESI-Q-TOF-MS/MS). By using the ion filtering approach, target constituents of Eucommia ulmoides Oliv. were easily tentatively identified from the enormous LC/MS data set. The strategy consisted of the following three steps: 1) To establishing a characteristic ion database by diagnostic product ions or neutral loss fragments; 2) To evaluate the structural information of the compounds by high-resolution diagnostic characteristic ion filtering; 3) To confirm the different classes by chemical profiling according to their MS/MS spectra. In this study, characteristic ions are summarized as five major groups of compounds in Eucommia ulmoides Oliv. In total, 113 compounds were tentatively identified, including 23 potentially novel compounds. The results form a foundation for the quality control and chemical basis of Eucommia ulmoides Oliv. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Comparison of the quantitative performance of a Q-Exactive high-resolution mass spectrometer with that of a triple quadrupole tandem mass spectrometer for the analysis of illicit drugs in wastewater.

    Science.gov (United States)

    Fedorova, Ganna; Randak, Tomas; Lindberg, Richard H; Grabic, Roman

    2013-08-15

    Analysis of drugs in wastewater is gaining more interest, as new approaches to estimate drug consumption from the amount of drug residues in wastewater have been proposed. The aim of this study was to compare the quantitative performance of high-resolution mass spectrometry with that of triple quadrupole mass spectrometry. A Q-Exactive mass spectrometer was operated in full scan (HRFS) (70 000 FWHM) and product scan (HRPS) (17 500 FWHM) modes. The first and third quadrupoles of the QqQ MS/MS instrument were operated at 0.7 FWHM. A mass-extracted window of 5 ppm around the theoretical m/z of each analyte was used to construct chromatograms. An HESI-II ion source was used for the ionization of target compounds. In-line-SPE-LC configuration was used for the extraction and separation of target analytes. All three methods showed good linearity and repeatability. High-resolution detection of product ions exhibited better sensitivity and selectivity for some compounds. For most of the tested compounds, LOQs ranged from 0.46 to 20 ng L(-1) . Good agreement between measured and nominal concentrations was observed for most of the compounds at different levels of fortification. Both MS/MS methods showed good selectivity, while HRFS gave some false positive results. The Q-Exactive mass spectrometer proved to be suitable for trace detection and quantification of most of the tested drugs in wastewater, with performance comparable to that of the commonly used MS/MS triple quadrupole, but with better selectivity. Copyright © 2013 John Wiley & Sons, Ltd.

  10. Analysis of 3-chloro-4-(dichloromethyl)-5-hydroxy-2(5H)-furanone (MX) and its brominated analogues in chlorine-treated water by gas chromatography coupled to triple quadrupole tandem mass spectrometry (GC-QqQ-MS/MS).

    Science.gov (United States)

    Planas, Carles; Ventura, Francesc; Caixach, Josep; Martín, Jordi; Boleda, M Rosa; Paraira, Miquel

    2015-11-01

    A simple, selective and sensitive method for the analysis of the strong mutagen 3-chloro-4-(dichloromethyl)-5-hydroxy-2(5H)-furanone (MX) and its brominated analogues (BMXs) in chlorine-treated water has been developed. The method is based on gas chromatography coupled to triple quadrupole tandem mass spectrometry (GC-QqQ-MS/MS), previous liquid-liquid extraction (LLE) of a smaller sample volume compared to other methods and on-line derivatization with a silylation reactive. GC-QqQ-MS/MS has been raised as an alternative easier to perform than gas chromatography coupled to high resolution mass spectrometry (GC-HRMS) for the analysis of MX and BMXs, and it allows to achieve low LODs (0.3 ng/L for MX and 0.4-0.9 ng/L for BMXs). This technique had not been previously described for the analysis of MX and BMXs. Quality parameters were calculated and real samples related to 3 drinking water treatment plants (DWTPs), tap water and both untreated and chlorinated groundwater were analyzed. Concentrations of 0.3-6.6 ng/L for MX and 1.0-7.3 ng/L for BMXs were detected. Results were discussed according to five of the main factors affecting MX and BMXs formation in chlorine-treated water (organic precursors, influence of bromide ions, evolution of MX and BMXs in the drinking water distribution system, groundwater chlorination and infiltration of water coming from chlorination processes in groundwater). Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Ion guide quadrupole mass spectrometer at Jyvaeskylae

    International Nuclear Information System (INIS)

    Iivonen, A.; Saintola, R.; Valli, K.; Morita, K.; Yoshida, A.

    1991-01-01

    A new mass analyzing device consisting of an ion guide connected to a commercial quadrupole mass spectrometer is being developed at the Department of Physics, University of Jyvaeskylae. The new spectrometer is expected to have the similar properties to the present ion guide isotope separator on-line (IGISOL): excellent stability, similar separation efficiency for all chemical elements and short separation time. This ion guide mass spectrometer (IGQMS) is schematically shown. The IGQMS differs from the IGISOL in four essential ways: a squeezer ion guide, a differential pumping section, a transport section in which an electrostatic lens system brings ions into high vacuum, and a commercial quadrupole spectrometer used in place of a magnetic separator. The entire spectrometer became operational in the summer of 1990. The tests have been done with the alpha-active Po-215 ions released from an Ac-227 source in the target chamber. The squeezer, differential pumping section, transport section and quadrupole mass spectrometer of the IGQMS are described. The results of the measured transmission yield and the total yield of Po-215 and some merits of the IGQMS are reported. (K.I.)

  12. Hydrogen isotope analysis by quadrupole mass spectrometry

    International Nuclear Information System (INIS)

    Ellefson, R.E.; Moddeman, W.E.; Dylla, H.F.

    1981-03-01

    The analysis of isotopes of hydrogen (H, D, T) and helium ( 3 He, 4 He) and selected impurities using a quadrupole mass spectrometer (QMS) has been investigated as a method of measuring the purity of tritium gas for injection into the Tokamak Fusion Test Reactor (TFTR). A QMS was used at low resolution, m/Δm 3 He, and 4 He in HT/D 2

  13. Sensitive characterization of polyphenolic antioxidants in Polygonatum odoratum by selective solid phase extraction and high performance liquid chromatography-diode array detector-quadrupole time-of-flight tandem mass spectrometry.

    Science.gov (United States)

    Hu, Xin; Zhao, Huading; Shi, Shuyun; Li, Hui; Zhou, Xiaoling; Jiao, Feipeng; Jiang, Xinyu; Peng, Dongming; Chen, Xiaoqin

    2015-08-10

    The complexity of natural products always leads to the co-elution of interfering compounds with bioactive compounds, which then has a detrimental effect on structural elucidation. Here, a new method, based on selective solid phase extraction combined with 1,1-diphenyl-2-picrylhydrazyl radical (DPPH) spiking and high performance liquid chromatography-diode array detector-quadrupole time-of-flight tandem mass spectrometry (HPLC-DAD-QTOF-MS/MS), is described for sensitive screening, selective extraction and identification of polyphenolic antioxidants in Polygonatum odoratum. First, 25 polyphenolic antioxidants (1-25) were screened by DPPH spiking with HPLC. Second, polydopamine coated Fe3O4 microspheres (Fe3O4@PDA) were prepared to selectively extract target antioxidants with extraction efficiency from 55% to 100% when the amount of Fe3O4@PDA, extraction time, desorption solvent and time were 10mg, 20 min, acetonitrile, and 5 min. Third, 25 antioxidants (10 cinnamides and 15 homoisoflavanones) were identified by HPLC-DAD-QTOF-MS/MS. Furthermore, the DPPH scavenging activities of purified compounds (IC50, 1.6-32.8 μg/mL) validated the method. Among the identified antioxidants, four of them (12, 13, 18 and 19) were new compounds, four of them (2, 4, 8 and 14) were first obtained from family Liliaceae, five of them (1, 3, 5, 7 and 9) were first reported in genus Polygonatum, while one compound (24) was first identified in this species. The results indicated that the proposed method was an efficient and sensitive approach to explore polyphenolic antioxidants from complex natural products. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Identification of regioisomers of methylated kaempferol and quercetin by ultra high performance liquid chromatography quadrupole time-of-flight (UHPLC–QTOF) tandem mass spectrometry combined with diagnostic fragmentation pattern analysis

    International Nuclear Information System (INIS)

    Ma, Chengying; Lv, Haipeng; Zhang, Xinzhong; Chen, Zongmao; Shi, Jiang; Lu, Meiling; Lin, Zhi

    2013-01-01

    Highlights: •Found methane elimination is position-specific for methylated flavonols. •Found retro Diels–Alder fragments retained methoxy at original ring of flavonols. •Proposed a diagnostic pattern for discriminating regioisomers of flavonols. •Identified the specificity of three novel flavonol O-methyltransferases. •Identified six biologically active compounds and four new compounds. -- Abstract: The O-methylation of active flavonoids can enhance their antiallergic, anticancerous, and cardioprotective effects depending on the methylation position. Thus, it is biologically and pharmacologically important to differentiate methylated flavonoid regioisomers. In this study, we examined the regioisomers of methylated kaempferol and quercetin using ultra high performance liquid chromatography quadrupole time-of-flight tandem mass spectrometry. The methyl groups on the flavonoids can generally be cleaved as methyl radicals in a position-independent manner. We found that methyl groups can be cleaved as methane. If there are protons adjacent the methoxy on the flavonol rings, intra-molecule proton transfer can occur via collision-induced dissociation, and one molecule of methane can then be eliminated. The remaining charged fragment ([M+H−CH 4 ] + ) reflects the adjacent structure and is specific to the methoxy position. Furthermore, the retro Diels–Alder (RDA) fragmentation of methylated flavonols can generate fragments with the methoxy at the original methylated ring. Combining the position-specific [M+H−CH 4 ] + fragment with the RDA fragments provides a diagnostic pattern for rapidly identifying methylated regioisomeric flavonols. Along with their retention behaviour, we have successfully identified ten regioisomers of methylated kaempferol and quercetin, which include six compounds previously reported in plants and shown to be biologically active. The developed approach is sensitive, rapid, reliable, and requires few standard compounds. It is highly

  15. Development and validation of a simple solid-phase extraction method coupled with liquid chromatography-triple quadrupole tandem mass spectrometry for simultaneous determination of lincomycin, tylosin A and tylosin B in royal jelly.

    Science.gov (United States)

    Zheng, Weijia; Park, Jin-A; Abd El-Aty, A M; Kim, Seong-Kwan; Cho, Sang-Hyun; Choi, Jeong-Min; Warda, Mohamad; Wang, Jing; Shim, Jae-Han; Shin, Ho-Chul

    2018-04-01

    We have developed an analytical method for the determination of lincomycin, tylosin A and tylosin B residues in royal jelly using liquid chromatography-triple quadrupole tandem mass spectrometry analysis. For extraction and purification, we employed 1% trifluoroacetic acid and 0.1 m Na 2 EDTA solutions along with an Oasis HLB cartridge. The target antibiotics were well separated in a Kinetex EVO C 18 reversed-phase analytical column using a combination of 0.1% formate acid in ultrapure water (A) and acetonitrile (B) as the mobile phase. Good linearity was achieved over the tested concentration range (5-50 μg/kg) in matrix-matched standard calibration. The coefficients of determination (R 2 ) were 0.9933, 0.9933 and 0.996, for tylosin A, tylosin B and lincomycin, respectively. Fortified royal jelly spiked with three different concentrations of the tested antibiotics (5, 10 and 20 μg/kg) yielded recoveries in the range 80.94-109.26% with relative standard deviations ≤4%. The proposed method was applied to monitor 11 brand of royal jelly collected from domestic markets and an imported brand from New Zealand; all the samples tested negative for lincomycin, tylosin A and tylosin B residues. In conclusion, 1% trifluoroacetic acid and 0.1 m Na 2 EDTA aqueous solvents combined with solid-phase extraction could effectively complete the sample preparation process for royal jelly before analysis. The developed approach can be applied for a routine analysis of lincomycin, tylosin A and tylosin B residues in royal jelly. Copyright © 2017 John Wiley & Sons, Ltd.

  16. Development of a multi-residue method for the determination of pesticides in cereals and dry animal feed using gas chromatography-tandem quadrupole mass spectrometry II. Improvement and extension to new analytes.

    Science.gov (United States)

    Walorczyk, Stanisław

    2008-10-24

    This paper describes the extension and re-validation of a previously published multi-residue method to currently 140 pesticides and 4 pesticide degradation products in cereals and feedingstuffs. The pesticides were extracted using buffered QuEChERS ("quick, easy, cheap, rugged, effective and safe") method and then cleaned up using dispersive solid-phase extraction with Bondesil PSA and C18 sorbents, and optionally by a freezing-out clean-up step. The final extracts were analyzed in a single injection gas chromatographic-tandem quadrupole mass spectrometric (GC-MS/MS) acquisition method. A high degree of confidence was achieved by entering two multiple reaction monitoring transitions per compound. In this way, quantification of analytical results and unequivocal identification of pesticide residues in compliance with the recent European Union criteria could be done in a single analysis. Thorough optimization of the GC-MS/MS acquisition conditions and application of an effective clean-up procedure has resulted in a remarkable enhancement of the validation parameters. The linearity of the calibration curves was excellent in matrix-matched standards, and yielded the coefficients of determination (R(2))> or =0.99 for approximately 96% of the target analytes. Average recoveries of the pesticides spiked at 0.01mgkg(-1) into a feed mixture and wheat grain were in the range 70-120% with associated RSD values feed mixtures and other samples such as malt, starch and dry vegetables have been analyzed. A total of 15 different pesticides have been detected, among which pirimiphos methyl (19 cases), deltamethrin (14 cases), tolylfluanid (5 cases), dichlofluanid (5 cases), and tebuconazole (4 cases) were the most frequently encountered ones.

  17. A new approach in proteomics of wheat gluten: combining chymotrypsin cleavage and matrix-assisted laser desorption/ionization quadrupole ion trap reflectron tandem mass spectrometry

    Czech Academy of Sciences Publication Activity Database

    Šalplachta, Jiří; Marchetti, M.; Chmelík, Josef; Allmaier, G.

    2005-01-01

    Roč. 19, č. 18 (2005), s. 2725-2728 ISSN 0951-4198 R&D Projects: GA MZe QD1023 Grant - others:Austrian Science Foundation(AT) P14181; Austrian Science Foundation;(AT) P15008 Institutional research plan: CEZ:AV0Z40310501 Keywords : wheat gluten * mass spectrometry * chymotrypsin Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.087, year: 2005

  18. Electrospray[+] tandem quadrupole mass spectrometry in the elucidation of ergot alkaloids chromatographed by HPLC: screening of grass or forage samples for novel toxic compounds.

    Science.gov (United States)

    Lehner, Andreas F; Craig, Morrie; Fannin, Neil; Bush, Lowell; Tobin, Tom

    2005-11-01

    Ergot alkaloids are mycotoxins generated by grass and grain pathogens such as Claviceps, for example. Ergot alkaloid-poisoning syndromes, such as tall fescue toxicosis from endophyte-infected tall fescue grass, are important veterinary problems for cattle, horses, sheep, pigs and chickens, with consequent impact on food, meat and dairy industries. Damage to livestock is of the order of a billion dollars a year in the United States alone. HPLC with UV and fluorescence detection are the predominant means of ergot alkaloid determination, with focus on quantitation of the marker compound ergovaline, although ELISA methods are undergoing investigation. These techniques are excellent for rapid detection, but of poor specificity in defining new or poorly characterized ergot alkaloids and related compounds. This paper demonstrates the facility of using electrospray(+) mass spectrometry with multiple reaction monitoring (MRM) detection during chromatographic examination of ergot alkaloid standards of lysergic acid, lysergol, ergonovine, ergovaline, ergotamine, ergocornine, ergocryptine and ergocrystine by HPLC. Ergoline-8 position epimers could be separated on the gradient HPLC system for ergocornine, ergocrystine and ergonovine and appeared as shoulders for ergotamine and ergovaline; epimers generally showed different patterns of relative intensity for specific MRM transitions. There was reasonable correspondence between retention of standards on the 2-mm ESI(+)MS phenyl-hexyl-based reverse phase column and those on the 4-mm C18-based column. Since up to 10% of clinical cases involving toxin exposure display unidentified chromatographic peaks, 11 samples of feed components associated with such cases were studied with developed MRM methods to attempt elucidation of crucial components if possible. Ergotamine appeared in all, ergovaline appeared in five and ergocornine appeared in six; ergonovine, ergocryptine, ergocrystine and lysergol also appeared in several. In addition

  19. Quality control and identification of steroid saponins in crude extracts from Dioscorea zingiberensis C. H. Wright by fingerprint with HPLC-ELSD and HPLC-ESI-Quadrupole/Time-of-fight tandem mass spectrometry

    Science.gov (United States)

    Zhang, Xinxin; Liang, Jinru; Liu, Jianli; Zhao, Ye; Gao, Juan; Sun, Wenji; Ito, Yoichiro

    2014-01-01

    In this study, a fingerprint of steroid saponins, the major bioactive constituents in the crude extracts from Dioscorea zingiberensis C. H. Wright (DZW), has been established for the first time by high-performance liquid chromatography coupled with evaporative light scattering detector (HPLC-ELSD) and the simultaneous characterization of the steroid saponins by high-performance liquid chromatography coupled with electrospray ionization-mass spectrometry and quadrupole tandem time-of-fight mass analyzers detection (HPLC-ESI-Q/TOF). These HPLC analyses were both carried out on a Welchrom C18 column (250 mm × 4.6 mm I.D., 5 μm) with a mobile phase composed of water and acetonitrile under gradient elution. There were 68 common characteristic peaks in the fingerprints, in which 12 of them were confirmed by comparing their mass spectra and retention times with those of the reference compounds. In order to identify the other unknown peaks, their fragmentation behaviors characteristic for the major groups of steroid saponins from DZW with six types of aglycone skeletons were discussed in detail, and possible MS/MS fragmentation pathways were proposed for aiding the structural identification of these components. According to the summarized fragmentation patterns, these peaks were tentatively assigned by matching their empirical molecular formula with those of the published compounds, or by elucidating their quasi-molecular ions and fragment ions referring to available literature information when the reference standards were unavailable. As a result, 22 steroid saponins were found in DZW for the first time. In addition, the quantitative analysis of the 12 known peaks was accomplished at the same time which indicated that there was a great variability in the amount of these active compounds in different batches in the crude extracts. This approach could demonstrate that the fingerprint could be considered to be a suitable tool to comprehensively improve the quality control

  20. Triple quadrupole tandem mass spectrometry: A real alternative to high resolution magnetic sector instrument for the analysis of polychlorinated dibenzo-p-dioxins, furans and dioxin-like polychlorinated biphenyls.

    Science.gov (United States)

    García-Bermejo, Ángel; Ábalos, Manuela; Sauló, Jordi; Abad, Esteban; González, María José; Gómara, Belén

    2015-08-19

    This paper reports on the optimisation, characterisation, validation and applicability of gas chromatography coupled to triple quadrupole mass spectrometry in its tandem operation mode (GC-QqQ(MS/MS) for the quantification of polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs, dioxins) and dioxin-like polychlorinated biphenyls (DL-PCBs) in environmental and food matrices. MS/MS parameters were selected to achieve the high sensitivity and selectivity required for the analysis of this type of compounds and samples. Good repeatability for areas (RSD = 1-10%, for PCDD/Fs and DL-PCBs) and for ion transition ratios (RSD = 0.3-10%, for PCDD/Fs, and 0.2-15%, for DL-PCBs) and low instrumental limits of detection, 0.07-0.75 pg μL(-1) (for dioxins) and 0.05-0.63 pg μL(-1) (for DL-PCBs), were obtained. A comparative study of the congener specific determination using both GC-QqQ(MS/MS) and gas chromatography-high resolution mass spectrometry (GC-HRMS) was also performed by analysing several fortified samples and certified reference materials (CRMs) with low (feed and foodstuffs), median (sewage sludge) and high (fly ash) toxic equivalency (TEQ) concentration levels, i.e. 0.60, 1.83, 72.9 and 3609 pg WHO-TEQ(PCDD/Fs) g(-1). The agreement between the results obtained for the total TEQs (dioxins) on GC-QqQ(MS/MS) and GC-HRMS in all the investigated samples were within the range of ±4%, and that of DL-PCBs at concentration levels of 0.84 pg WHO-TEQs (DL-PCBs) g(-1), in the case of feedstuffs, was 0.11%. Both instrumental methods have similar and comparable linearity, precision and accuracy. The GC-QqQ(MS/MS) sensitivity, lower than that of GC-HRMS, is good enough (iLODs in the down to low pg levels) to detect the normal concentrations of these compounds in food and environmental samples. These results make GC-QqQ(MS/MS) suitable for the quantitative analysis of dioxins and DL-PCBs and a real alternative tool to the reference sector HRMS instruments. Copyright © 2015 Elsevier

  1. Identification of regioisomers of methylated kaempferol and quercetin by ultra high performance liquid chromatography quadrupole time-of-flight (UHPLC–QTOF) tandem mass spectrometry combined with diagnostic fragmentation pattern analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Chengying; Lv, Haipeng; Zhang, Xinzhong; Chen, Zongmao; Shi, Jiang [Tea Research Institute, Chinese Academy of Agricultural Sciences, 9 Meiling South Road, Hangzhou, Zhejiang 310008 (China); Lu, Meiling, E-mail: meilinglu@hotmail.com [Chemical Analysis Group, Agilent Technologies, No. 3 Wangjing North Road, Chaoyang Distr., Beijing 100102 (China); Lin, Zhi, E-mail: linz@mail.tricaas.com [Tea Research Institute, Chinese Academy of Agricultural Sciences, 9 Meiling South Road, Hangzhou, Zhejiang 310008 (China)

    2013-09-17

    Highlights: •Found methane elimination is position-specific for methylated flavonols. •Found retro Diels–Alder fragments retained methoxy at original ring of flavonols. •Proposed a diagnostic pattern for discriminating regioisomers of flavonols. •Identified the specificity of three novel flavonol O-methyltransferases. •Identified six biologically active compounds and four new compounds. -- Abstract: The O-methylation of active flavonoids can enhance their antiallergic, anticancerous, and cardioprotective effects depending on the methylation position. Thus, it is biologically and pharmacologically important to differentiate methylated flavonoid regioisomers. In this study, we examined the regioisomers of methylated kaempferol and quercetin using ultra high performance liquid chromatography quadrupole time-of-flight tandem mass spectrometry. The methyl groups on the flavonoids can generally be cleaved as methyl radicals in a position-independent manner. We found that methyl groups can be cleaved as methane. If there are protons adjacent the methoxy on the flavonol rings, intra-molecule proton transfer can occur via collision-induced dissociation, and one molecule of methane can then be eliminated. The remaining charged fragment ([M+H−CH{sub 4}]{sup +}) reflects the adjacent structure and is specific to the methoxy position. Furthermore, the retro Diels–Alder (RDA) fragmentation of methylated flavonols can generate fragments with the methoxy at the original methylated ring. Combining the position-specific [M+H−CH{sub 4}]{sup +} fragment with the RDA fragments provides a diagnostic pattern for rapidly identifying methylated regioisomeric flavonols. Along with their retention behaviour, we have successfully identified ten regioisomers of methylated kaempferol and quercetin, which include six compounds previously reported in plants and shown to be biologically active. The developed approach is sensitive, rapid, reliable, and requires few standard

  2. Higher Order Parametric Excitation Modes for Spaceborne Quadrupole Mass Spectrometers

    Science.gov (United States)

    Gershman, D. J.; Block, B. P.; Rubin, M.; Benna, M.; Mahaffy, P. R.; Zurbuchen, T. H.

    2011-01-01

    This paper describes a technique to significantly improve upon the mass peak shape and mass resolution of spaceborne quadrupole mass spectrometers (QMSs) through higher order auxiliary excitation of the quadrupole field. Using a novel multiresonant tank circuit, additional frequency components can be used to drive modulating voltages on the quadrupole rods in a practical manner, suitable for both improved commercial applications and spaceflight instruments. Auxiliary excitation at frequencies near twice that of the fundamental quadrupole RF frequency provides the advantages of previously studied parametric excitation techniques, but with the added benefit of increased sensed excitation amplitude dynamic range and the ability to operate voltage scan lines through the center of upper stability islands. Using a field programmable gate array, the amplitudes and frequencies of all QMS signals are digitally generated and managed, providing a robust and stable voltage control system. These techniques are experimentally verified through an interface with a commercial Pfeiffer QMG422 quadrupole rod system.When operating through the center of a stability island formed from higher order auxiliary excitation, approximately 50% and 400% improvements in 1% mass resolution and peak stability were measured, respectively, when compared with traditional QMS operation. Although tested with a circular rod system, the presented techniques have the potential to improve the performance of both circular and hyperbolic rod geometry QMS sensors.

  3. First determination of C 60 and C 70 fullerenes and N-methylfulleropyrrolidine C 60 on the suspended material of wastewater effluents by liquid chromatography hybrid quadrupole linear ion trap tandem mass spectrometry

    Science.gov (United States)

    Farré, Marinella; Pérez, Sandra; Gajda-Schrantz, Krisztina; Osorio, Victoria; Kantiani, Lina; Ginebreda, Antoni; Barceló, Damià

    2010-03-01

    SummaryThe increasing use and production of carbon-based nanoparticles demands for new analytical approaches able to achieve sensitivities in the low ng/L range in order to assess their presence in environmental samples. This paper describes development, optimization and validation of a novel method for the analysis of C 60 and, C 70 fullerenes and N-methylfulleropyrrolidine C 60 in the environment. The method relies on ultrasonication extraction from suspended solids in wastewater, followed by liquid chromatography (LC) coupled to a hybrid triple quadrupole linear ion trap mass spectrometry (QqLIT-MS) for trace quantification. Recoveries obtained were generally higher than 60% for both surface water and wastewaters. The overall variability of the method was below 15%, for the three fullerenes and all tested matrices: ultra-pure water, surface water and wastewater. For the effluents of wastewater treatment plants the method quantification limits (MQL) ranged from 0.2 to 1 ng/L. The precision of the method, calculated as relative standard deviation (RSD), ranged from 1% to 2% and from 5% to 9% for intra and inter-day analysis, respectively. The developed analytical method was applied to the analysis of fullerenes in the effluents of 22 wastewater treatment plants in Catalonia (NE of Spain). 50% of the analyzed samples contained fullerenes, nine of them in the μg/L concentration range. This work constitutes the first report on the occurrence of fullerenes in suspended solids of wastewater effluents highlighting the need of nanotechnologies residues assessment for risk evaluation of nanoparticles in the environment.

  4. Quantification of bupivacaine hydrochloride and isoflupredone acetate residues in porcine muscle, beef, milk, egg, shrimp, flatfish, and eel using a simplified extraction method coupled with liquid chromatography-triple quadrupole tandem mass spectrometry.

    Science.gov (United States)

    Cho, Sang-Hyun; Park, Jin-A; Zheng, Weijia; Abd El-Aty, A M; Kim, Seong-Kwan; Choi, Jeong-Min; Yi, Hee; Cho, Soo-Min; Afifi, Nehal A; Shim, Jae-Han; Chang, Byung-Joon; Kim, Jin-Suk; Shin, Ho-Chul

    2017-10-15

    In this study, a simple analytical approach has been developed and validated for the determination of bupivacaine hydrochloride and isoflupredone acetate residues in porcine muscle, beef, milk, egg, shrimp, flatfish, and eel using liquid chromatography-tandem mass spectrometry (LC-MS/MS). A 0.1% solution of acetic acid in acetonitrile combined with n-hexane was used for deproteinization and defatting of all tested matrices and the target drugs were well separated on a Waters Xbridge™ C18 analytical column using a mobile phase consisting of 0.1% acetic acid (A) and 0.1% solution of acetic acid in methanol (B). The linearity estimated from six-point matrix-matched calibrations was good, with coefficients of determination ≥0.9873. The limits of quantification (LOQs) for bupivacaine hydrochloride and isoflupredone acetate were 1 and 2ngg -1 , respectively. Recovery percentages in the ranges of 72.51-112.39% (bupivacaine hydrochloride) and 72.58-114.56% (isoflupredone acetate) were obtained from three different fortification concentrations with relative standard deviations (RSDs) of bupivacaine hydrochloride and isoflupredone acetate from porcine muscle, beef, milk, egg, shrimp, flatfish, and eel samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Development of a Tandem-Electrostatic-Quadrupole facility for Accelerator-Based Boron Neutron Capture Therapy.

    Science.gov (United States)

    Kreiner, A J; Castell, W; Di Paolo, H; Baldo, M; Bergueiro, J; Burlon, A A; Cartelli, D; Vento, V Thatar; Kesque, J M; Erhardt, J; Ilardo, J C; Valda, A A; Debray, M E; Somacal, H R; Sandin, J C Suarez; Igarzabal, M; Huck, H; Estrada, L; Repetto, M; Obligado, M; Padulo, J; Minsky, D M; Herrera, M; Gonzalez, S J; Capoulat, M E

    2011-12-01

    We describe the present status of an ongoing project to develop a Tandem-ElectroStatic-Quadrupole (TESQ) accelerator facility for Accelerator-Based (AB)-BNCT. The project final goal is a machine capable of delivering 30 mA of 2.4 MeV protons to be used in conjunction with a neutron production target based on the (7)Li(p,n)(7)Be reaction. The machine currently being constructed is a folded TESQ with a high-voltage terminal at 0.6 MV. We report here on the progress achieved in a number of different areas. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. Development of a Tandem-Electrostatic-Quadrupole facility for Accelerator-Based Boron Neutron Capture Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kreiner, A.J., E-mail: kreiner@tandar.cnea.gov.ar [Gerencia de Investigacion y Aplicaciones, Comision Nacional de Energia Atomica, Av. Gral Paz 1499, 1650 San Martin, Buenos Aires (Argentina)] [Escuela de Ciencia y Tecnologia, Universidad Nacional de San Martin (Argentina)] [CONICET, Buenos Aires (Argentina); Castell, W. [Gerencia de Investigacion y Aplicaciones, Comision Nacional de Energia Atomica, Av. Gral Paz 1499, 1650 San Martin, Buenos Aires (Argentina); Di Paolo, H. [Gerencia de Investigacion y Aplicaciones, Comision Nacional de Energia Atomica, Av. Gral Paz 1499, 1650 San Martin, Buenos Aires (Argentina)] [Escuela de Ciencia y Tecnologia, Universidad Nacional de San Martin (Argentina); Baldo, M. [Gerencia de Investigacion y Aplicaciones, Comision Nacional de Energia Atomica, Av. Gral Paz 1499, 1650 San Martin, Buenos Aires (Argentina); Bergueiro, J. [Gerencia de Investigacion y Aplicaciones, Comision Nacional de Energia Atomica, Av. Gral Paz 1499, 1650 San Martin, Buenos Aires (Argentina)] [CONICET, Buenos Aires (Argentina)

    2011-12-15

    We describe the present status of an ongoing project to develop a Tandem-ElectroStatic-Quadrupole (TESQ) accelerator facility for Accelerator-Based (AB)-BNCT. The project final goal is a machine capable of delivering 30 mA of 2.4 MeV protons to be used in conjunction with a neutron production target based on the {sup 7}Li(p,n){sup 7}Be reaction. The machine currently being constructed is a folded TESQ with a high-voltage terminal at 0.6 MV. We report here on the progress achieved in a number of different areas.

  7. A robust platform based on ultra-high performance liquid chromatography Quadrupole time of flight tandem mass spectrometry with a two-step data mining strategy in the investigation, classification, and identification of chlorogenic acids in Ainsliaea fragrans Champ.

    Science.gov (United States)

    Ouyang, Hui; Li, Junmao; Wu, Bei; Zhang, Xiaoyong; Li, Yan; Yang, Shilin; He, Mingzhen; Feng, Yulin

    2017-06-16

    The chlorogenic acids are the major bioactive constituents of the whole plant of Ainsliaea fragrans Champ. (Xingxiang Tuerfeng). These compounds are usually present as isomeric forms in Xingxiang Tuerfeng. Therefore, an efficient approach should be developed for the rapid discovery and identification of chlorogenic acids isomers through the fragmentation pathway and rules. In this study, the collision induced dissociation tandem mass spectrometry (CID-MS/MS) fragmentation routes of chlorogenic acids were systematically investigated by UHPLC-QTOF-MS/MS in the negative ion mode using eight chlorogenic acids standards. As a result, diagnostic product ions for rapid discovery and classification of chlorogenic acids isomers were determined according to their MS/MS fragmentation patterns and intensity analysis. Based on these findings, a novel two-step data mining strategy was established. The first key step was to screen different kinds of substitution and the skeleton of the quinic acid using the characteristic product ions and neutral losses. The second key step was to screen and classify different types of chlorogenic acids using their diagnostic product ions. It was apply to the rapid investigation, classification, and identification of chlorogenic acids. And the same carbon skeletons from a complex extract of Ainsliaea fragrans Champ. were effectively identified. 88 constituents, including 14 chlorogenic acids types, were rapidly discovered and identified, and in particular, 12 types of chlorogenic acids, including p-CoQC, FQA, BQC, CQA-Glu, CFQA, p-Co-CQC, di-p-CoQC, BCQA, di-CQA-Glu, PCQA, tri-QCA, and P-di-CQA, were first discovered in Ainsliaea fragrans Champ. In conclusion, UHPLC-QTOF-MS/MS method together with a systematic two-step data mining strategy was established as a feasible, effective, and rational technique for analyzing chlorogenic acids. Additionally, this study laid a foundation for the study of the active substances and quality control of

  8. Targeted Proteomic Quantification on Quadrupole-Orbitrap Mass Spectrometer*

    Science.gov (United States)

    Gallien, Sebastien; Duriez, Elodie; Crone, Catharina; Kellmann, Markus; Moehring, Thomas; Domon, Bruno

    2012-01-01

    There is an immediate need for improved methods to systematically and precisely quantify large sets of peptides in complex biological samples. To date protein quantification in biological samples has been routinely performed on triple quadrupole instruments operated in selected reaction monitoring mode (SRM), and two major challenges remain. Firstly, the number of peptides to be included in one survey experiment needs to be increased to routinely reach several hundreds, and secondly, the degree of selectivity should be improved so as to reliably discriminate the targeted analytes from background interferences. High resolution and accurate mass (HR/AM) analysis on the recently developed Q-Exactive mass spectrometer can potentially address these issues. This instrument presents a unique configuration: it is constituted of an orbitrap mass analyzer equipped with a quadrupole mass filter as the front-end for precursor ion mass selection. This configuration enables new quantitative methods based on HR/AM measurements, including targeted analysis in MS mode (single ion monitoring) and in MS/MS mode (parallel reaction monitoring). The ability of the quadrupole to select a restricted m/z range allows one to overcome the dynamic range limitations associated with trapping devices, and the MS/MS mode provides an additional stage of selectivity. When applied to targeted protein quantification in urine samples and benchmarked with the reference SRM technique, the quadrupole-orbitrap instrument exhibits similar or better performance in terms of selectivity, dynamic range, and sensitivity. This high performance is further enhanced by leveraging the multiplexing capability of the instrument to design novel acquisition methods and apply them to large targeted proteomic studies for the first time, as demonstrated on 770 tryptic yeast peptides analyzed in one 60-min experiment. The increased quality of quadrupole-orbitrap data has the potential to improve existing protein

  9. A qualitative study of amlodipine and its related compounds by electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Gibbons, John; Pugh, Jonathan; Dimopoulos-Italiano, Gina; Pike, Richard

    2006-01-01

    A comprehensive structural analysis of amlodipine and certain related compounds was performed by electrospray ionization tandem mass spectrometry. Triple quadrupole and quadrupole time-of-flight instruments were used to provide collision-induced dissociation and accurate mass measurement for selected product and second-generation product ions. A unique ion rearrangement was observed, which was found to be characteristic of certain dihydropyridines. This study provides a fundamental understanding of the fragmentation of these compounds. The structural elucidation of an unknown impurity is presented as an example. Copyright (c) 2006 John Wiley & Sons, Ltd.

  10. Characterisation of fulvic acids by electrospray with quadrupole / time-of-flight mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Plancque, G. [Commissariat a l' Energie Atomique, Centre de Saclay, Direction de l' Energie Nucleaire / DPC / SECR / Lab. de Speciation des Radionucleides et des Molecules, Gif-sur-Yvette (France)

    2004-07-01

    Characterisation of fulvic and humic acids (FA and HA) - synthetic model substances M1 and M42 from FZR, FA and HA Gohy 573 from the Gorleben groundwaters from FZK and purified Aldrich HA from CTU - has been performed using a quadrupole time-of-flight (QTOF) mass spectrometer equipped with an electrospray ionisation interface. The same conclusions as for Mol fulvic acids, previously studied in the laboratory, can be drawn: molecular masses centred around 350 Da, sinusoidal spectral distributions, even and odd integral masses distributions and presence of dimmers (and possible trimmers) in negative-mode experiments have been observed for all humic substances. Tandem mass spectrometry (MS/MS) has also been used and experiments showed losses of 18 Da (H{sub 2}O), 28 Da (CO) and 44 Da (CO{sub 2}) as for Mol FA. No obvious differences, in terms of molecular structure, are observed compared to Mol FA. (orig.)

  11. A quadrupole mass spectrometer system for nuclear safeguards applications

    International Nuclear Information System (INIS)

    Evans, P.J.

    1987-12-01

    An on-line enrichment monitor for nuclear safeguards-related surveillance of a pilot-scale gas centrifuge plant is described. This monitor utilises a quadrupole mass spectrometer to measure the isotopic composition of UF 6 in the feed and product gas streams. Details of the design and construction are given, and several difficulties are identified and discussed. Finally, the performance of this system is illustrated with typical results

  12. Mass spectrometry by means of tandem accelerators

    International Nuclear Information System (INIS)

    Tuniz, C.

    1985-01-01

    Mass spectrometry based on an accelerator allows to measure rare cosmogenic isotopes found in natural samples with isotopic abundances up to 10E-15. The XTU Tandem of Legnaro National Laboratories can measure mean heavy isotopes (36Cl, 41Ca, 129I) in applications interesting cosmochronology and Medicine. The TTT-3 Tandem of the Naples University has been modified in view of precision studies of C14 in Archeology, Paleantology and Geology. In this paper a review is made of principles and methodologies and of some applicationy in the framework of the National Program for mass spectrametry research with the aid of accelerators

  13. Determination of phosphodiesterase type V inhibitors in wastewater by direct injection followed by liquid chromatography coupled to tandem mass spectrometry

    NARCIS (Netherlands)

    Causanilles, A.; Emke, E.; de Voogt, P.

    2016-01-01

    A simple, fast and reliable analytical method for the determination of phosphodiesterase type V inhibitors in wastewater was developed and validated. The method was based on direct injection followed by liquid chromatography coupled to tandem mass spectrometry with triple quadrupole as mass

  14. Homotopy analysis method to study a quadrupole mass filter.

    Science.gov (United States)

    Seddighi Chaharborj, S; Seddighi Chahrborj, S; Sadat Kiai, S M; Abu Bakar, M R; Ziaeian, I; Gheisari, Y

    2012-04-01

    The homotopy analysis method (HAM) is applied to study the behavior of a hyperbolic rods of quadrupole mass filter and a sinusoidal potential form V(ac)  cos(Ωt). Numerical computation method of a 20th-order HAM is employed to compare the physical properties of the confined ions with fifth-order Runge-Kutta method. Also, comparison is made for the first stability region, the ion trajectories in real time, the polar plots, and the ion trajectory in x - y plan. The results show that the two methods are fairly similar; therefore, the HAM method has potential application to solve linear and nonlinear equations of the charge particle confinement in quadrupole field. Copyright © 2012 John Wiley & Sons, Ltd.

  15. Application of a highly sensitive magnetic solid phase extraction for phytochemical compounds in medicinal plant and biological fluids by ultra-high performance liquid chromatography coupled with quadrupole time-of-flight tandem mass spectrometry.

    Science.gov (United States)

    Cao, Wan; Yi, Ling; Ye, Li-Hong; Cao, Jun; Hu, Shuai-Shuai; Xu, Jing-Jing; Peng, Li-Qing; Zhu, Qiong-Yao; Zhang, Qian-Yun

    2015-10-01

    A highly sensitive method using reduced graphene oxide with iron oxide (rGO/Fe3 O4 ) as the sorbent in magnetic SPE has been developed for the purification of five anthraquinones (emodin, rhein, aloeemodin, physcion, and chrysophanol) in rhubarb and rat urine by ultra-HPLC coupled with quadrupole TOF/MS. The extraction was accomplished by adding trace amount rGO/Fe3 O4 suspension to 200 mL of aqueous mixture, and the excellent adsorption capacity of the nanoparticles was fully demonstrated in this procedure. Under the optimized conditions, the calibration curves were linear in the concentration range of 0.05-27.77 ng/mL with correlation coefficients varying from 0.9902 to 0.9978. The LODs ranged from 0.28 to 58.99 pg/mL. The experimental results indicated that the proposed method was feasible for the analysis of anthraquinones in rhubarb and urine samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Quality evaluation of tandem mass spectral libraries.

    Science.gov (United States)

    Oberacher, Herbert; Weinmann, Wolfgang; Dresen, Sebastian

    2011-06-01

    Tandem mass spectral libraries are gaining more and more importance for the identification of unknowns in different fields of research, including metabolomics, forensics, toxicology, and environmental analysis. Particularly, the recent invention of reliable, robust, and transferable libraries has increased the general acceptance of these tools. Herein, we report on results obtained from thorough evaluation of the match reliabilities of two tandem mass spectral libraries: the MSforID library established by the Oberacher group in Innsbruck and the Weinmann library established by the Weinmann group in Freiburg. Three different experiments were performed: (1) Spectra of the libraries were searched against their corresponding library after excluding either this single compound-specific spectrum or all compound-specific spectra prior to searching; (2) the libraries were searched against each other using either library as reference set or sample set; (3) spectra acquired on different mass spectrometric instruments were matched to both libraries. Almost 13,000 tandem mass spectra were included in this study. The MSforID search algorithm was used for spectral matching. Statistical evaluation of the library search results revealed that principally both libraries enable the sensitive and specific identification of compounds. Due to higher mass accuracy of the QqTOF compared with the QTrap instrument, matches to the MSforID library were more reliable when comparing spectra with both libraries. Furthermore, only the MSforID library was shown to be efficiently transferable to different kinds of tandem mass spectrometers, including "tandem-in-time" instruments; this is due to the coverage of a large range of different collision energy settings-including the very low range-which is an outstanding characteristics of the MSforID library.

  17. Interpretation of tandem mass spectra of posttranslationally modified peptides

    DEFF Research Database (Denmark)

    Bunkenborg, J.; Matthiesen, R.

    2013-01-01

    Tandem mass spectrometry provides a sensitive means of analyzing the amino acid sequence of peptides and modified peptides by providing accurate mass measurements of precursor and fragment ions. Modern mass spectrometry instrumentation is capable of rapidly generating many thousands of tandem mas...... and validating tandem mass spectra and gives some useful tables to aid this process....

  18. Portable Tandem Mass Spectrometer Analyzer

    Science.gov (United States)

    1991-07-01

    FILE : MHCI TUNE TABLE 84 (SCANNING with PARENT) SCAN RANGE 10.9 TO 700.0 TUNE MASS 355.0 (AUTO) >LENS 1-3 -13. 88 0. 2: POFF - 1. 2 9: COFF - 4. 1 3...and 500 ng of caffeine in I uL of chloroform by GC/A?:,,MS using negative ions. Also analyzed were barbiturates, extracted from urine, in the 3-5 Mg

  19. FAST DETECTION OF ACETYLSALICYLIC ACID BY LIQUID CHROMATOGRAPHY TANDEM MASS SPECTROMETRY(LC-MSMS)

    OpenAIRE

    Abusoglu, Sedat; Unlu, Ali; Sivrikaya, Abdullah

    2018-01-01

    ObjectivesAcetylsalicylic acid (ASA) is themost widely used as an analgesic, anti-inflammatory and antipyretic drug, andalso used to inhibit cyclooxygenase dependent platelet aggregation.   The aimof this study was to develop a simple, fast and accurate tandem mass method fordetermination and quantification of ASA.  MethodsChromatographic seperation was performedusing an Shimadzu LC-20-AD (Kyoto, Japan) coupledwith a ABSCIEX API 3200 triple quadrupole massspectromete...

  20. Electrostatic design and beam transport for a folded tandem electrostatic quadrupole accelerator facility for accelerator-based boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Thatar Vento, V., E-mail: Vladimir.ThatarVento@gmail.com [Gerencia de Investigacion y Aplicaciones, CNEA, Av. Gral. Paz 1499 (1650), San Martin, Buenos Aires (Argentina)] [CONICET, Av. Rivadavia 1917 (1033), Ciudad Autonoma de Buenos Aires (Argentina); Bergueiro, J.; Cartelli, D. [Gerencia de Investigacion y Aplicaciones, CNEA, Av. Gral. Paz 1499 (1650), San Martin, Buenos Aires (Argentina)] [CONICET, Av. Rivadavia 1917 (1033), Ciudad Autonoma de Buenos Aires (Argentina); Valda, A.A. [Gerencia de Investigacion y Aplicaciones, CNEA, Av. Gral. Paz 1499 (1650), San Martin, Buenos Aires (Argentina)] [Escuela de Ciencia y Tecnologia, UNSAM, M. Irigoyen 3100 (1650), San Martin, Buenos Aires (Argentina); Kreiner, A.J. [Gerencia de Investigacion y Aplicaciones, CNEA, Av. Gral. Paz 1499 (1650), San Martin, Buenos Aires (Argentina)] [CONICET, Av. Rivadavia 1917 (1033), Ciudad Autonoma de Buenos Aires (Argentina)] [Escuela de Ciencia y Tecnologia, UNSAM, M. Irigoyen 3100 (1650), San Martin, Buenos Aires (Argentina)

    2011-12-15

    Within the frame of an ongoing project to develop a folded Tandem-Electrostatic-Quadrupole (TESQ) accelerator facility for Accelerator-Based Boron Neutron Capture Therapy (AB-BNCT), we discuss here the electrostatic design of the machine, including the accelerator tubes with electrostatic quadrupoles and the simulations for the transport and acceleration of a high intensity beam.

  1. Rapid Quadrupole-Time-of-Flight Mass Spectrometry Method Quantifies Oxygen-Rich Lignin Compound in Complex Mixtures

    Science.gov (United States)

    Boes, Kelsey S.; Roberts, Michael S.; Vinueza, Nelson R.

    2018-03-01

    Complex mixture analysis is a costly and time-consuming task facing researchers with foci as varied as food science and fuel analysis. When faced with the task of quantifying oxygen-rich bio-oil molecules in a complex diesel mixture, we asked whether complex mixtures could be qualitatively and quantitatively analyzed on a single mass spectrometer with mid-range resolving power without the use of lengthy separations. To answer this question, we developed and evaluated a quantitation method that eliminated chromatography steps and expanded the use of quadrupole-time-of-flight mass spectrometry from primarily qualitative to quantitative as well. To account for mixture complexity, the method employed an ionization dopant, targeted tandem mass spectrometry, and an internal standard. This combination of three techniques achieved reliable quantitation of oxygen-rich eugenol in diesel from 300 to 2500 ng/mL with sufficient linearity (R2 = 0.97 ± 0.01) and excellent accuracy (percent error = 0% ± 5). To understand the limitations of the method, it was compared to quantitation attained on a triple quadrupole mass spectrometer, the gold standard for quantitation. The triple quadrupole quantified eugenol from 50 to 2500 ng/mL with stronger linearity (R2 = 0.996 ± 0.003) than the quadrupole-time-of-flight and comparable accuracy (percent error = 4% ± 5). This demonstrates that a quadrupole-time-of-flight can be used for not only qualitative analysis but also targeted quantitation of oxygen-rich lignin molecules in complex mixtures without extensive sample preparation. The rapid and cost-effective method presented here offers new possibilities for bio-oil research, including: (1) allowing for bio-oil studies that demand repetitive analysis as process parameters are changed and (2) making this research accessible to more laboratories. [Figure not available: see fulltext.

  2. Rapid Quadrupole-Time-of-Flight Mass Spectrometry Method Quantifies Oxygen-Rich Lignin Compound in Complex Mixtures

    Science.gov (United States)

    Boes, Kelsey S.; Roberts, Michael S.; Vinueza, Nelson R.

    2017-12-01

    Complex mixture analysis is a costly and time-consuming task facing researchers with foci as varied as food science and fuel analysis. When faced with the task of quantifying oxygen-rich bio-oil molecules in a complex diesel mixture, we asked whether complex mixtures could be qualitatively and quantitatively analyzed on a single mass spectrometer with mid-range resolving power without the use of lengthy separations. To answer this question, we developed and evaluated a quantitation method that eliminated chromatography steps and expanded the use of quadrupole-time-of-flight mass spectrometry from primarily qualitative to quantitative as well. To account for mixture complexity, the method employed an ionization dopant, targeted tandem mass spectrometry, and an internal standard. This combination of three techniques achieved reliable quantitation of oxygen-rich eugenol in diesel from 300 to 2500 ng/mL with sufficient linearity (R2 = 0.97 ± 0.01) and excellent accuracy (percent error = 0% ± 5). To understand the limitations of the method, it was compared to quantitation attained on a triple quadrupole mass spectrometer, the gold standard for quantitation. The triple quadrupole quantified eugenol from 50 to 2500 ng/mL with stronger linearity (R2 = 0.996 ± 0.003) than the quadrupole-time-of-flight and comparable accuracy (percent error = 4% ± 5). This demonstrates that a quadrupole-time-of-flight can be used for not only qualitative analysis but also targeted quantitation of oxygen-rich lignin molecules in complex mixtures without extensive sample preparation. The rapid and cost-effective method presented here offers new possibilities for bio-oil research, including: (1) allowing for bio-oil studies that demand repetitive analysis as process parameters are changed and (2) making this research accessible to more laboratories. [Figure not available: see fulltext.

  3. Development of a tandem-electrostatic-quadrupole accelerator facility for BNCT.

    Science.gov (United States)

    Kreiner, A J; Thatar Vento, V; Levinas, P; Bergueiro, J; Di Paolo, H; Burlon, A A; Kesque, J M; Valda, A A; Debray, M E; Somacal, H R; Minsky, D M; Estrada, L; Hazarabedian, A; Johann, F; Suarez Sandin, J C; Castell, W; Davidson, J; Davidson, M; Giboudot, Y; Repetto, M; Obligado, M; Nery, J P; Huck, H; Igarzabal, M; Fernandez Salares, A

    2009-07-01

    In this work we describe the present status of an ongoing project to develop a tandem-electrostatic-quadrupole (TESQ) accelerator facility for accelerator-based (AB) BNCT at the Atomic Energy Commission of Argentina in Buenos Aires. The project final goal is a machine capable of delivering 30 mA of 2.4 MeV protons to be used in conjunction with a neutron production target based on the (7)Li(p,n)(7)Be reaction slightly beyond its resonance at 2.25 MeV. These are the specifications needed to produce sufficiently intense and clean epithermal neutron beams, based on the (7)Li(p,n)(7)Be reaction, to perform BNCT treatment for deep-seated tumors in less than an hour. An electrostatic machine is the technologically simplest and cheapest solution for optimized AB-BNCT. The machine being designed and constructed is a folded TESQ with a high-voltage terminal at 1.2 MV intended to work in air. Such a machine is conceptually shown to be capable of transporting and accelerating a 30 mA proton beam to 2.4 MeV. The general geometric layout, its associated electrostatic fields, and the acceleration tube are simulated using a 3D finite element procedure. The design and construction of the ESQ modules is discussed and their electrostatic fields are investigated. Beam transport calculations through the accelerator are briefly mentioned. Likewise, work related to neutron production targets, strippers, beam shaping assembly and patient treatment room is briefly described.

  4. Protein Sequencing with Tandem Mass Spectrometry

    Science.gov (United States)

    Ziady, Assem G.; Kinter, Michael

    The recent introduction of electrospray ionization techniques that are suitable for peptides and whole proteins has allowed for the design of mass spectrometric protocols that provide accurate sequence information for proteins. The advantages gained by these approaches over traditional Edman Degradation sequencing include faster analysis and femtomole, sometimes attomole, sensitivity. The ability to efficiently identify proteins has allowed investigators to conduct studies on their differential expression or modification in response to various treatments or disease states. In this chapter, we discuss the use of electrospray tandem mass spectrometry, a technique whereby protein-derived peptides are subjected to fragmentation in the gas phase, revealing sequence information for the protein. This powerful technique has been instrumental for the study of proteins and markers associated with various disorders, including heart disease, cancer, and cystic fibrosis. We use the study of protein expression in cystic fibrosis as an example.

  5. Screening of drugs and toxic compounds with liquid chromatography-linear ion trap tandem mass spectrometry.

    Science.gov (United States)

    Sauvage, François-Ludovic; Saint-Marcoux, Franck; Duretz, Bénédicte; Deporte, Didier; Lachatre, Gérard; Marquet, Pierre

    2006-09-01

    In clinical and forensic toxicology, general unknown screening is used to detect and identify exogenous compounds. In this study, we aimed to develop a comprehensive general unknown screening method based on liquid chromatography coupled with a hybrid triple-quadrupole linear ion trap mass spectrometer. After solid-phase extraction, separation was performed using gradient reversed-phase chromatography. The mass spectrometer was operated in the information-dependent acquisition mode, switching between a survey scan acquired in the Enhanced Mass Spectrometry mode with dynamic subtraction of background noise and a dependent scan obtained in the enhanced product ion scan mode. The complete cycle time was 1.36 s. A library of 1000 enhanced product ion-tandem mass spectrometry spectra in positive mode and 250 in negative mode, generated using 3 alternated collision tensions during each scan, was created by injecting pure solutions of drugs and toxic compounds. Comparison with HPLC-diode array detection and gas chromatography-mass spectrometry for the analysis of 36 clinical samples showed that linear ion trap tandem mass spectrometry could identify most of the compounds (94% of the total). Some compounds were detected only by 1 of the other 2 techniques. Specific clinical cases highlighted the advantages and limitations of the method. A unique combination of new operating modes provided by hybrid triple-quadrupole linear ion trap mass spectrometers and new software features allowed development of a comprehensive and efficient method for the general unknown screening of drugs and toxic compounds in blood or urine.

  6. High-sensitivity mass spectrometry with a tandem accelerator

    International Nuclear Information System (INIS)

    Henning, W.

    1984-01-01

    The characteristic features of accelerator mass spectrometry are discussed. A short overview is given of the current status of mass spectrometry with high-energy (MeV/nucleon) heavy-ion accelerators. Emphasis is placed on studies with tandem accelerators and on future mass spectrometry of heavier isotopes with the new generation of higher-voltage tandems

  7. SSC collider quadrupole cold mass design and development

    International Nuclear Information System (INIS)

    Farrell, R.A.; Murray, F.S.; Jonas, P.A.; Mischler, W.R.; Blecher, L.

    1992-01-01

    Approximately 1,664 focussing and defocussing superconducting quadrupoles are required for the two SSC collider rings. Collider quadruple magnets (CQMS) must satisfy stringent performance, reliability, life and low cost criteria. Performance requirements include field uniformity, training, quench, tracking, thermal cycling and alignment. The CQM cold mass design presented incorporates lessons IGC and Alsthom Intermagnetics S.A. (AISA), our joint venture with GEC-Alsthom, learned in the design, development and manufacture of 500 MRI, 160 high-field custom and 126 HERA quadruple superconducting magnets. This baseline design reflects careful quantitative assessment of coil winding placement and collar material, evaluation of field uniformity and mechanical performance of the magnet coil ends using 3-D modeling and analysis, and considers tolerance and process variability. Selected CQM cold mass design highlights and a proposed prototype development program that allows incorporation of test feedback into the design to minimize risk are detailed in this paper. This information may be helpful to SSCL in the design and development of prototype CQM'S

  8. High Energy Collisions on Tandem Time-of-Flight Mass Spectrometers

    Science.gov (United States)

    Cotter, Robert J.

    2013-05-01

    Long before the introduction of matrix-assisted laser desorption/ionization (MALDI), electrospray ionization (ESI), Orbitraps, and any of the other tools that are now used ubiquitously for proteomics and metabolomics, the highest performance mass spectrometers were sector instruments, providing high resolution mass measurements by combining an electrostatic energy analyzer (E) with a high field magnet (B). In its heyday, the four sector mass spectrometer (or EBEB) was the crown jewel, providing the highest performance tandem mass spectrometry using single, high energy collisions to induce fragmentation. During a time in which quadrupole and tandem triple quadrupole instruments were also enjoying increased usage and popularity, there were, nonetheless, some clear advantages for sectors over their low collision energy counterparts. Time-of-flight (TOF) mass spectrometers are high voltage, high vacuum instruments that have much in common with sectors and have inspired the development of tandem instruments exploiting single high energy collisions. In this retrospective, we recount our own journey to produce high performance TOFs and tandem TOFs, describing the basic theory, problems, and the advantages for such instruments. An experiment testing impulse collision theory (ICT) underscores the similarities with sector mass spectrometers where this concept was first developed. Applications provide examples of more extensive fragmentation, side chain cleavages, and charge-remote fragmentation, also characteristic of high energy sector mass spectrometers. Moreover, the so-called curved-field reflectron has enabled the design of instruments that are simpler, collect and focus all of the ions, and may provide the future technology for the clinic, for tissue imaging, and the characterization of microorganisms.

  9. Electrostatic design and beam transport for a folded tandem electrostatic quadrupole accelerator facility for accelerator-based boron neutron capture therapy.

    Science.gov (United States)

    Vento, V Thatar; Bergueiro, J; Cartelli, D; Valda, A A; Kreiner, A J

    2011-12-01

    Within the frame of an ongoing project to develop a folded Tandem-Electrostatic-Quadrupole (TESQ) accelerator facility for Accelerator-Based Boron Neutron Capture Therapy (AB-BNCT), we discuss here the electrostatic design of the machine, including the accelerator tubes with electrostatic quadrupoles and the simulations for the transport and acceleration of a high intensity beam. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Simultaneous Determination of 25 Common Pharmaceuticals in Whole Blood Using Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Marie Katrine Klose; Johansen, Sys Stybe

    2012-01-01

    An ultra-performance liquid chromatography-tandem mass spectrometry method was developed and validated for the quantification of 25 common pharmaceuticals in whole blood. The selected pharmaceuticals represent the most frequently detected drugs in our forensic laboratory with basic properties...... elution using a Waters ACQUITY Ultra-Performance Liquid Chromatography system. Quantification was performed on a Waters tandem quadrupole ACQUITY TQD using multiple reaction monitoring in positive mode. The analytes were eluted within 11 min. The limit of quantification (LOQ) ranged from 0.002 to 0.01 mg...

  11. Direct trace analysis of metals and alloys in a quadrupole ion-trap mass spectrometer

    CERN Document Server

    Song, K S; Yang, M; Cha, H K; Lee, J M; Lee, G H

    1999-01-01

    An ion-trap mass spectrometer adopting a quadrupole ion-trap and laser ablation/ionization method was constructed. The developed system was tested for composition analysis of some metals (Cu, stainless), and alloys (hastalloy C, mumetal) by mass spectrometry. Samples were analyzed by using laser ablation from a sample probe tip followed by a mass analysis with the quadrupole ion-trap. The quadrupole ion-trap was modified to enable laser ablation by a XeCl excimer laser pulse that passed radially through the ring electrode. A mass scan of the produced ions was performed in the mass selective instability mode wherein trapped ions were successively detected by increasing the rf voltage through the ring electrode. Factors affecting the mass resolution, such as pressure of buffer gas and ablation laser power, are discussed.

  12. Study of New Analytical Methodologies for the Analysis of Polychlorinated Dibenzo-P-Dioxins (PCDDs) and Polychlorinated Di benzofurans (PCDFs) by Quadrupole Ion Storage Tandem-in-time Mass Spectrometry. Application to Environmental Samples; Estudio de nuevas metodologias analiticas en la determinacion de policlorodibenzo-P-dioxinas (PCDDs) y policlosrodibenzofuranos (PCDFs) por espectrometria de masas con trampa ionica. Aplicacion a muestras medioambientales

    Energy Technology Data Exchange (ETDEWEB)

    Sanz Chichon, M. P.

    2008-07-01

    Two alternative analytical methodologies have been developed for the analysis of polychlorinated dibenzo-p-dioxins (PCDDs) and di benzofurans (PCDFs) in environmental samples. The techniques studied have been: Pressurized Fluid Extraction (PFE) and Microwave-Assisted Extraction (MAE) versus Soxhlet extraction; the automated system Power-PrepTM versus the conventional cleanup using open chromatographic columns with different adsorbents and the application of tandem mass spectrometry (HRGC-MS/MS) versus high resolution mass spectrometry (HRGC-HRMS) for PCDD/Fs detection and quantification. (Author) 233 refs.

  13. Analysis of posttranslational modifications of proteins by tandem mass spectrometry

    DEFF Research Database (Denmark)

    Larsen, Martin Røssel; Trelle, Morten B; Thingholm, Tine E

    2006-01-01

    -temporal distribution in cells and tissues. Most PTMs can be detected by protein and peptide analysis by mass spectrometry (MS), either as a mass increment or a mass deficit relative to the nascent unmodified protein. Tandem mass spectrometry (MS/MS) provides a series of analytical features that are highly useful...

  14. Doping control analysis of anabolic steroids in equine urine by gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Wong, April S Y; Leung, Gary N W; Leung, David K K; Wan, Terence S M

    2017-09-01

    Anabolic steroids are banned substances in equine sports. Gas chromatography-mass spectrometry (GC-MS) has been the traditional technique for doping control analysis of anabolic steroids in biological samples. Although liquid chromatography-mass spectrometry (LC/MS) has become an important technique in doping control, the detection of saturated hydroxysteroids by LC-MS remains a problem due to their low ionization efficiency under electrospray. The recent development in fast-scanning gas-chromatography-triple-quadrupole mass spectrometry (GC-MS/MS) has provided a better alternative with a significant reduction in chemical noise by means of selective reaction monitoring. Herein, we present a sensitive and selective method for the screening of over 50 anabolic steroids in equine urine using gas chromatography-tandem mass spectrometry (GC-MS/MS). Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  15. Multistage Fragmentation of Ion Trap Mass Spectrometry System and Pseudo-MS3 of Triple Quadrupole Mass Spectrometry Characterize Certain (E-3-(Dimethylamino-1-arylprop-2-en-1-ones: A Comparative Study

    Directory of Open Access Journals (Sweden)

    Ali S. Abdelhameed

    2014-01-01

    Full Text Available A new approach was recently introduced to improve the structure elucidation power of tandem mass spectrometry simulating the MS3 of ion trap mass spectrometry system overcoming the different drawbacks of the latter. The fact that collision induced dissociation in the triple quadrupole mass spectrometer system provides richer fragment ions compared to those achieved in the ion trap mass spectrometer system utilizing resonance excitation. Moreover, extracting comprehensive spectra in the ion trap needs multistage fragmentation, whereas similar fragment ions may be acquired from one stage product ion scan using the triple quadrupole mass spectrometer. The new strategy was proven to enhance the qualitative performance of tandem mass spectrometry for structural elucidation of different chemical entities. In the current study we are endeavoring to prove our hypothesis of the efficiency of the new pseudo-MS3 technique via its comparison with the MS3 mode of ion trap mass spectrometry system. Ten pharmacologically and synthetically important (E-3-(dimethylamino-1-arylprop-2-en-1-ones (enaminones 4a–j were chosen as model compounds for this study. This strategy permitted rigorous identification of all fragment ions using triple quadrupole mass spectrometer with sufficient specificity. It can be used to elucidate structures of different unknown components. The data presented in this paper provide clear evidence that our new pseudo-MS3 may simulate the MS3 of ion trap spectrometry system.

  16. Quantitative proteomics using the high resolution accurate mass capabilities of the quadrupole-orbitrap mass spectrometer.

    Science.gov (United States)

    Gallien, Sebastien; Domon, Bruno

    2014-08-01

    High resolution/accurate mass hybrid mass spectrometers have considerably advanced shotgun proteomics and the recent introduction of fast sequencing capabilities has expanded its use for targeted approaches. More specifically, the quadrupole-orbitrap instrument has a unique configuration and its new features enable a wide range of experiments. An overview of the analytical capabilities of this instrument is presented, with a focus on its application to quantitative analyses. The high resolution, the trapping capability and the versatility of the instrument have allowed quantitative proteomic workflows to be redefined and new data acquisition schemes to be developed. The initial proteomic applications have shown an improvement of the analytical performance. However, as quantification relies on ion trapping, instead of ion beam, further refinement of the technique can be expected.

  17. Mass peak shape improvement of a quadrupole mass filter when operating with a rectangular wave power supply.

    Science.gov (United States)

    Luo, Chan; Jiang, Dan; Ding, Chuan-Fan; Konenkov, Nikolai V

    2009-09-01

    Numeric experiments were performed to study the first and second stability regions and find the optimal configurations of a quadrupole mass filter constructed of circular quadrupole rods with a rectangular wave power supply. The ion transmission contours were calculated using ion trajectory simulations. For the first stability region, the optimal rod set configuration and the ratio r/r(0) is 1.110-1.115; for the second stability region, it is 1.128-1.130. Low-frequency direct current (DC) modulation with the parameters of m = 0.04-0.16 and nu = omega/Omega = 1/8-1/14 improves the mass peak shape of the circular rod quadrupole mass filter at the optimal r/r(0) ratio of 1.130. The amplitude modulation does not improve mass peak shape. Copyright (c) 2009 John Wiley & Sons, Ltd.

  18. Tandem Mass Spectrometry of Novel Ether-Linked Phospholipid Analogs of Anionic Pulmonary Surfactant Phospholipids

    Science.gov (United States)

    Fickes, Rachel; Voelker, Dennis R.; Berry, Karin Zemski; Murphy, Robert C.

    2016-01-01

    RATIONALE Structural analogs of the bioactive lipid, 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphoglycerol, were synthesized with a xylitol polar headgroup and both diacyl and diether radyl groups. Mass spectral characterization of xylitol phospholipids (PX) was carried out using collisional activation and high resolution mass measurements of positive molecular ion species and compared with the phosphatidylglycerol (PG) analogs. METHODS Xylitol phospholipids were synthesized using a transphosphatidylation reaction catalyzed by phospholipase D and purified by HPLC. Compounds were subjected to electrospray ionization and CID was performed using a tandem quadrupole mass spectrometer to generate positive and negative molecular ions. Diether phospholipids were additionally analyzed by high resolution mass spectrometry as protonated and sodiated molecular species in positive ion mode. RESULTS Ester linked xylitol phospholipid analogs behaved similar to PG after collisional activation of [M-H]−. The product ions formed by CID of the diether PG and PX negative ions only revealed information about the headgroup with no information about the aliphatic chains. In contrast, CID of protonated and sodiated diether phospholipid positive ions, revealed reactions corresponding to cleavage of the ether chain, likely occurring by charge driven reaction mechanisms. CONCLUSIONS Novel xylitol phospholipid analogs with diacyl and diether radyl substituents of the glycerol backbone were characterized by tandem mass spectrometry. These unique diether phospholipid analogs enabled exploration of ether cleavage reactions of the positive molecular ion species induced by collision induced decomposition. PMID:27689848

  19. Interfacing an aspiration ion mobility spectrometer to a triple quadrupole mass spectrometer

    International Nuclear Information System (INIS)

    Adamov, Alexey; Viidanoja, Jyrki; Kaerpaenoja, Esko; Paakkanen, Heikki; Ketola, Raimo A.; Kostiainen, Risto; Sysoev, Alexey; Kotiaho, Tapio

    2007-01-01

    This article presents the combination of an aspiration-type ion mobility spectrometer with a mass spectrometer. The interface between the aspiration ion mobility spectrometer and the mass spectrometer was designed to allow for quick mounting of the aspiration ion mobility spectrometer onto a Sciex API-300 triple quadrupole mass spectrometer. The developed instrumentation is used for gathering fundamental information on aspiration ion mobility spectrometry. Performance of the instrument is demonstrated using 2,6-di-tert-butyl pyridine and dimethyl methylphosphonate

  20. Quadrupole mass spectrometer for a mobile laboratory to measure isotope ratios

    Energy Technology Data Exchange (ETDEWEB)

    Walton, J.R.; Smith, D.H.; McKown, H.S.; Carter, J.A.

    1981-01-01

    A mobile laboratory has been assembled for on-site inspection of plant operations handlng special nuclear materials. The isotopic composition of U, Pu, and other elements can be analyzed using a quadrupole mass spectrometer. Some results of analysis of uranium and boron standards are given. (DLC)

  1. Triple Quadrupole Versus High Resolution Quadrupole-Time-of-Flight Mass Spectrometry for Quantitative LC-MS/MS Analysis of 25-Hydroxyvitamin D in Human Serum

    Science.gov (United States)

    Geib, Timon; Sleno, Lekha; Hall, Rabea A.; Stokes, Caroline S.; Volmer, Dietrich A.

    2016-08-01

    We describe a systematic comparison of high and low resolution LC-MS/MS assays for quantification of 25-hydroxyvitamin D3 in human serum. Identical sample preparation, chromatography separations, electrospray ionization sources, precursor ion selection, and ion activation were used; the two assays differed only in the implemented final mass analyzer stage; viz. high resolution quadrupole-quadrupole-time-of-flight (QqTOF) versus low resolution triple quadrupole instruments. The results were assessed against measured concentration levels from a routine clinical chemiluminescence immunoassay. Isobaric interferences prevented the simple use of TOF-MS spectra for extraction of accurate masses and necessitated the application of collision-induced dissociation on the QqTOF platform. The two mass spectrometry assays provided very similar analytical figures of merit, reflecting the lack of relevant isobaric interferences in the MS/MS domain, and were successfully applied to determine the levels of 25-hydroxyvitamin D for patients with chronic liver disease.

  2. Interpretation of Tandem Mass Spectrometry (MSMS) Spectra for Peptide Analysis

    DEFF Research Database (Denmark)

    Hjernø, Karin; Højrup, Peter

    2015-01-01

    The aim of this chapter is to give a short introduction to peptide analysis by mass spectrometry (MS) and interpretation of fragment mass spectra. Through examples and guidelines we demonstrate how to understand and validate search results and how to perform de novo sequencing based on the often...... very complex fragmentation pattern obtained by tandem mass spectrometry (also referred to as MSMS). The focus is on simple rules for interpretation of MSMS spectra of tryptic as well as non-tryptic peptides....

  3. Quadrupole mass spectrometer driver with higher signal levels

    Science.gov (United States)

    Chutjian, Ara (Inventor); Aalami, Dean (Inventor); Darrach, Murray (Inventor); Orient, Otto (Inventor)

    2003-01-01

    Driving a quadrapole mass spectrometer includes obtaining an air core transformer with a primary and a secondary, matching the secondary to the mass spectrometer, and driving the primary based on first and second voltage levels. Driving of the primary is via an isolating stage that minimizes low level drive signal coupling.

  4. Ultra Performance Liquid Chromatography Tandem Mass ...

    African Journals Online (AJOL)

    NICOLAAS

    drugs alone.16. After a single oral dose of 120–800 mg of NTB in healthy sub- jects in a fasting state the peak plasma NTB concentration (tmax) was found to be 4–7 h, with a half-life of approximately 9–17 h.17 ... performance liquid chromatography mass spectrometry/mass .... to the likely biological plasma constituents.

  5. [Application of tandem mass spectrometry in diagnosis of organic acidemias].

    Science.gov (United States)

    Han, Lian-shu; Gao, Xiao-lan; Ye, Jun; Qiu, Wen-juan; Gu, Xue-fan

    2005-05-01

    The diagnosis of organic acidemia is very difficult and needs special test methods. Recently the tandem mass spectrometry has been used in screening for and diagnosis of this inborn error of metabolism. The aim of the present study was to utilize a dry blood filter paper method for acylcarnitines profiles test using tandem mass spectrometry in diagnosis of organic acidemias in high risk children. One thousand patients (642 were males and 358 females) with high risk of inborn error of metabolism were studied, the median of their age was 2 years. The blood specimens were collected on filter paper, punched and extracted into methanol solution with stable isotope labeled internal standards of acylcarnitine, then derivatized with butanolic-HCI. After preparation, the samples were analyzed by tandem mass spectrometry. The volume of the acylcarnitines was calculated with special software. Forty patients (4.0%) were diagnosed as organic acidemias among the 1000 patients, including 20 methylmalonic acidemia, 6 propionic acidemia, 3 isovaleric acidemia, 3 glutaric acidemia type I, 3 glutaric acidemia type II, 2 biotinidas deficiency, 1 3-methylcrotonyl-CoA carboxylase deficiency, 1 3-hydroxy-3-methylglutaryl-CoA lyase deficiency, and 1 beta-keto thiolase deficiency. The common clinical symptoms and signs of these patients were motor and mental developmental retardation, spasm, lethargy, coma, hypotonia, vomiting, and feeding difficulty. Routine laboratory tests suggested metabolic acidosis, hyperammonemia, hyperlactacidemia, hypoglycemia, anemia, and abnormal liver function. A part of organic acidemias can be rapidly diagnosed by tandem mass spectrometry through acylcarnitine profiles analysis in dry blood filter paper. Combination of tandem mass spectrometry with urine gas chromatography mass spectrometry would improve more accurate diagnosis of organic acidemias.

  6. Tandem mass spectrometric analysis of novel peptide-modified gemini surfactants used as gene delivery vectors.

    Science.gov (United States)

    Al-Dulaymi, M; El-Aneed, A

    2017-06-01

    Diquaternary ammonium gemini surfactants have emerged as effective gene delivery vectors. A novel series of 11 peptide-modified compounds was synthesized, showing promising results in delivering genetic materials. The purpose of this work is to elucidate the tandem mass spectrometric (MS/MS) dissociation behavior of these novel molecules establishing a generalized MS/MS fingerprint. Exact mass measurements were achieved using a hybrid quadrupole orthogonal time-of-flight mass spectrometer, and a multi-stage MS/MS analysis was conducted using a triple quadrupole-linear ion trap mass spectrometer. Both instruments were operated in the positive ionization mode and are equipped with electrospray ionization. Abundant triply charged [M+H] 3+ species were observed in the single-stage analysis of all the evaluated compounds with mass accuracies of less than 8 ppm in mass error. MS/MS analysis showed that the evaluated gemini surfactants exhibited peptide-related dissociation characteristics because of the presence of amino acids within the compounds' spacer region. In particular, diagnostic product ions were originated from the neutral loss of ammonia from the amino acids' side chain resulting in the formation of pipecolic acid at the N-terminus part of the gemini surfactants. In addition, a charge-directed amide bond cleavage was initiated by the amino acids' side chain producing a protonated α-amino-ε-caprolactam ion and its complimentary C-terminus ion that contains quaternary amines. MS/MS and MS 3 analysis revealed common fragmentation behavior among all tested compounds, resulting in the production of a universal MS/MS fragmentation pathway. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  7. Annotating and Interpreting Linear and Cyclic Peptide Tandem Mass Spectra.

    Science.gov (United States)

    Niedermeyer, Timo Horst Johannes

    2016-01-01

    Nonribosomal peptides often possess pronounced bioactivity, and thus, they are often interesting hit compounds in natural product-based drug discovery programs. Their mass spectrometric characterization is difficult due to the predominant occurrence of non-proteinogenic monomers and, especially in the case of cyclic peptides, the complex fragmentation patterns observed. This makes nonribosomal peptide tandem mass spectra annotation challenging and time-consuming. To meet this challenge, software tools for this task have been developed. In this chapter, the workflow for using the software mMass for the annotation of experimentally obtained peptide tandem mass spectra is described. mMass is freely available (http://www.mmass.org), open-source, and the most advanced and user-friendly software tool for this purpose. The software enables the analyst to concisely annotate and interpret tandem mass spectra of linear and cyclic peptides. Thus, it is highly useful for accelerating the structure confirmation and elucidation of cyclic as well as linear peptides and depsipeptides.

  8. Analysis of posttranslational modifications of proteins by tandem mass spectrometry

    DEFF Research Database (Denmark)

    Larsen, Martin Røssel; Trelle, Morten B; Thingholm, Tine E

    2006-01-01

    -temporal distribution in cells and tissues. Most PTMs can be detected by protein and peptide analysis by mass spectrometry (MS), either as a mass increment or a mass deficit relative to the nascent unmodified protein. Tandem mass spectrometry (MS/MS) provides a series of analytical features that are highly useful...... for the characterization of modified proteins via amino acid sequencing and specific detection of posttranslationally modified amino acid residues. Large-scale, quantitative analysis of proteins by MS/MS is beginning to reveal novel patterns and functions of PTMs in cellular signaling networks and biomolecular structures....

  9. Effects of the source gap on transmission efficiency of a quadrupole mass spectrometer.

    Science.gov (United States)

    Antony Joseph, Mariya J; McIntosh, David; Gibson, Ray; Taylor, Stephen

    2018-02-28

    Recent trends towards miniature and portable quadrupole mass spectrometry (QMS) entail challenges in instrumental sensitivity, which is influenced by 3D fringe field effects on ion transmission in the Quadrupole Mass Filter (QMF). The relationship of these effects with the gap from the ion source to the QMF entrance (source gap) is significant and little explored. We examine transmission characteristics experimentally and use the results to test the predictive accuracy of a recently-developed 3D QMF simulation model. The model is then applied to directly investigate optimal transmission m/z ranges across multiple source gaps. Experimental: A portable single filter quadrupole mass spectrometer is used to analyse transmission characteristics across a range of common gases. We use an experimental approach originally proposed by Ehlert, enhanced with a novel method for absolute calibration of the transmission curve. Simulation: Custom QMF simulation software employs the boundary element method (BEM) to compute accurate 3D electric fields. This is used to study the effects of the source gap on transmission efficiency. Experimental findings confirm a centrally peaked transmission curve; simulations correctly predict the optimal transmission location (in m/z) and percentage, and extend the experimental trend. We compare several methods for determining fringe field length, demonstrating how the size of the physical source gap influences both the length and the intensity of the fringe field at the QMF entrance. A complex relationship with ion transmission is revealed in which different source gaps promote optimal transmission at differing m/z ranges. The presented results map the relationship between the source gap and transmission efficiency for the given instrument, using a simulation method transferrable to other setups. This is of importance to miniature and portable quadrupole mass spectrometers designed for specific applications, for the first time enabling the source

  10. Atmospheric pressure ionization-tandem mass spectrometry of the phenicol drug family.

    Science.gov (United States)

    Alechaga, Élida; Moyano, Encarnación; Galceran, M Teresa

    2013-11-01

    In this work, the mass spectrometry behaviour of the veterinary drug family of phenicols, including chloramphenicol (CAP) and its related compounds thiamphenicol (TAP), florfenicol (FF) and FF amine (FFA), was studied. Several atmospheric pressure ionization sources, electrospray (ESI), atmospheric pressure chemical ionization and atmospheric pressure photoionization were compared. In all atmospheric pressure ionization sources, CAP, TAP and FF were ionized in both positive and negative modes; while for the metabolite FFA, only positive ionization was possible. In general, in positive mode, [M + H](+) dominated the mass spectrum for FFA, while the other compounds, CAP, TAP and FF, with lower proton affinity showed intense adducts with species present in the mobile phase. In negative mode, ESI and atmospheric pressure photoionization showed the deprotonated molecule [M-H](-), while atmospheric pressure chemical ionization provided the radical molecular ion by electron capture. All these ions were characterized by tandem mass spectrometry using the combined information obtained by multistage mass spectrometry and high-resolution mass spectrometry in a quadrupole-Orbitrap instrument. In general, the fragmentation occurred via cyclization and losses or fragmentation of the N-(alkyl)acetamide group, and common fragmentation pathways were established for this family of compounds. A new chemical structure for the product ion at m/z 257 for CAP, on the basis of the MS(3) and MS(4) spectra is proposed. Thermally assisted ESI and selected reaction monitoring are proposed for the determination of these compounds by ultra high-performance liquid chromatography coupled to tandem mass spectrometry, achieving instrumental detection limits down to 0.1 pg. Copyright © 2013 John Wiley & Sons, Ltd.

  11. System Assessment and Calibrations of the Kundsen Effusion QuadrupoleMass Spectrometer

    OpenAIRE

    黄 錦涛; 古川 智弘

    2000-01-01

    A vapor pressure measurement instrument was set up by utilizing the "Microvision Plus(LM70)" quadrupole mass spectrometer combined with the Knudsen vapor effusion cell. The purpose of the vapor pressure measurement is to obtain reliable thermodynamic data of sodium-iron complex compounds. Then, the behaviors of these compounds in various environmental conditions can be investigated in detail for analysis of sodium-leak related accidents in fast breeder reactors(FBR). Therefore, the reliabilit...

  12. High-throughput shotgun lipidomics by quadrupole time-of-flight mass spectrometry

    DEFF Research Database (Denmark)

    Ståhlman, Marcus; Ejsing, Christer S.; Tarasov, Kirill

    2009-01-01

    the absolute quantification of hundreds of molecular glycerophospholipid species, glycerolipid species, sphingolipid species and sterol lipids. Future applications in clinical cohort studies demand detailed lipid molecule information and the application of high-throughput lipidomics platforms. In this review...... we describe a novel high-throughput shotgun lipidomic platform based on 96-well robot-assisted lipid extraction, automated sample infusion by mircofluidic-based nanoelectrospray ionization, and quantitative multiple precursor ion scanning analysis on a quadrupole time-of-flight mass spectrometer...

  13. Series fabrication of the main quadrupole cold masses for the LHC begins

    CERN Multimedia

    2003-01-01

    Three hundred and sixty main quadrupole (MQ) magnets will perform the principal beam focusing around the 27 km LHC ring. CERN and CEA-Saclay began collaborating on the development and prototyping of these magnets in 1989. This resulted in five highly successful quadrupole units - also known as short straight sections - one of which was integrated for testing in String 1, and two others of the final design in String 2. Once the tests had confirmed the validity of the design and realization, the fabrication of the 360 cold masses had to be transferred to industry.The German firm ACCEL Instruments was entrusted both with the construction of the quadrupole magnets themselves, and with their assembly into the cold masses together with various combinations of corrector magnets produced by other European manufacturers. Here we see the first of the cold masses containing the MQ magnet of the machine arcs together with two types of corrector magnet ready for shipping to CERN. This first unit was delivered on 12 Februa...

  14. Series fabrication of the main quadrupole cold masses for the LHC begins

    CERN Multimedia

    2003-01-01

    Three hundred and sixty main quadrupole (MQ) magnets will perform the principal beam focusing around the 27 km LHC ring. CERN and CEA-Saclay began collaborating on the development and prototyping of these magnets in 1989. This resulted in five highly successful quadrupole units - also known as short straight sections - one of which was integrated for testing in String 1, and two others of the final design in String 2. Once the tests had confirmed the validity of the design and realization, the fabrication of the 360 cold masses had to be transferred to industry.The German firm ACCEL Instruments was entrusted both with the construction of the quadrupole magnets themselves, and with their assembly into the cold masses together with various combinations of corrector magnets produced by other European manufacturers. Here we see the first of the cold masses containing the MQ magnet of the machine arcs together with two types of corrector magnet ready for shipping to CERN. Pictured with this first unit, delivered o...

  15. Identification of novel sites of O-N-acetylglucosamine modification of serum response factor using quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Chalkley, Robert J; Burlingame, A L

    2003-03-01

    The addition of a single N-acetylglucosamine moiety O-linked to serine and threonine residues of nuclear and cytoplasmic proteins is a widespread post-translational modification. The conventional method for detecting and locating sites of modification is through a multistep radioactivity-based approach. We have recently shown that sites of O-GlcNAc modification can be determined using quadrupole time-of-flight tandem mass spectrometry (Chalkley, R. J., and Burlingame, A. L. (2001) Identification of GlcNAcylation sites of peptides and alpha-crystallin using Q-TOF mass spectrometry. J. Am. Soc. Mass Spectrom. 12, 1106-1113). In this work utilization of this new approach has revealed previously undetected sites of O-GlcNAc modification of the transcription factor serum response factor.

  16. [Tandem mass spectrometry as screening for inborn errors of metabolism].

    Science.gov (United States)

    Campos H, Derbis

    2011-10-01

    The use of tandem mass spectrometry for the diagnosis of inborn errors of metabolism has the potential to expand the newborn screening panel to include a vast number of diseases. This technology allows the detection, in the same spot of dried blood on filter paper and during one single analytical run, of different metabolic diseases. Tandem mass spectrometry is rapidly replacing the classical screening techniques approach of one-metabolite detected per analysis per disease by its ability of simultaneous quantification of several metabolites as markers of many diseases, such as acylcarnitines and amino acids. It is clear that a single metabolite can be a biomarker for several diseases, so the multiplex approach of using tandem mass spectrometry enhances, on average, the sensitivity and specificity of the screening. However, there are differences for particular metabolites and the diseases they detect within the same method. Disorders such as the tyrosinemias and among the organic acidemias, the methylmalonic acidemias, have a substantially higher false-positive rate than other more common metabolic diseases such as medium-chain acyl-CoA dehydrogenase deficiency and phenylketonuria. Before introducing this technology into routine newborn screening programs it is necessary to consider the frequency of each disease, as well as the response to early treatment or variables related to the collection of the sample.

  17. Accelerator mass spectrometry with a coupled tandem-linac system

    International Nuclear Information System (INIS)

    Kutschera, W.

    1984-01-01

    A coupled system provides higher energies, which allows one to extend AMS to hitherto untouched mass regions. Another important argument is that the complexity, although bothersome for the operation, increases the selectivity of detecting a particular isotope. The higher-energy argument holds for any heavy-ion accelerator which is capable of delivering higher energy than a tandem. The present use of tandem-linac combinations for AMS, rather than cyclotrons, linacs or combinations of these machines, has mainly to do with the fact that this technique was almost exclusively developed around tandem accelerators. Therefore the tandem-linac combination is a natural extension to higher energies. The use of negative ions has some particular advantages in suppressing background from unwanted elements that do not form stable negative ions (e.g., N, Mg, Ar). On the other hand, this limits the detection of isotopes to elements which do form negative ions. For particular problems it may therefore be advantageous to use a positive-ion machine. What really matters most for choosing one or the other machine is to what extent the entire accelerator system can be operated in a truly quantiative way from the ion source to the detection system. 20 references, 4 figures

  18. Development of high intensity ion sources for a Tandem-Electrostatic-Quadrupole facility for Accelerator-Based Boron Neutron Capture Therapy

    International Nuclear Information System (INIS)

    Bergueiro, J.; Igarzabal, M.; Suarez Sandin, J.C.; Somacal, H.R.; Thatar Vento, V.; Huck, H.; Valda, A.A.; Repetto, M.

    2011-01-01

    Several ion sources have been developed and an ion source test stand has been mounted for the first stage of a Tandem-Electrostatic-Quadrupole facility For Accelerator-Based Boron Neutron Capture Therapy. A first source, designed, fabricated and tested is a dual chamber, filament driven and magnetically compressed volume plasma proton ion source. A 4 mA beam has been accelerated and transported into the suppressed Faraday cup. Extensive simulations of the sources have been performed using both 2D and 3D self-consistent codes.

  19. Development of high intensity ion sources for a Tandem-Electrostatic-Quadrupole facility for Accelerator-Based Boron Neutron Capture Therapy.

    Science.gov (United States)

    Bergueiro, J; Igarzabal, M; Sandin, J C Suarez; Somacal, H R; Vento, V Thatar; Huck, H; Valda, A A; Repetto, M; Kreiner, A J

    2011-12-01

    Several ion sources have been developed and an ion source test stand has been mounted for the first stage of a Tandem-Electrostatic-Quadrupole facility For Accelerator-Based Boron Neutron Capture Therapy. A first source, designed, fabricated and tested is a dual chamber, filament driven and magnetically compressed volume plasma proton ion source. A 4 mA beam has been accelerated and transported into the suppressed Faraday cup. Extensive simulations of the sources have been performed using both 2D and 3D self-consistent codes. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. Improved tandem mass spectrometer coupled to a laser vaporization cluster ion source

    Science.gov (United States)

    Förstel, Marko; Jaeger, Bertram K. A.; Schewe, Wolfgang; Sporkhorst, Philipp H. A.; Dopfer, Otto

    2017-12-01

    We describe two improvements to an existing tandem mass spectrometer coupled to a laser vaporization cluster ion source suitable for photodissociation spectroscopy: (i) cooling of the cluster source nozzle and (ii) mass selection prior to the photodissociation region via replacing an octupole ion guide by a quadrupole mass spectrometer. The improved sensitivity and transmission enable the production of larger heteroatomic clusters as well as rare gas solvated clusters. We present two examples demonstrating the new capabilities of the improved setup. In the first application, cooling of the cluster source nozzle produces Si+Arn and Si2+Arn cluster cations with n = 1-25. Magic numbers are extracted from the mass spectrum by applying a transmission function obtained via simulations. In the second example, the vibronic photodissociation spectrum of cold Au4+ cluster ions is recorded with unprecedented detail, resolution, and sensitivity. Such high-resolution optical excitation spectra of metal cluster cations may serve as a benchmark for the performance of Franck-Condon simulations based on quantum chemical calculations for excited states.

  1. Development of a totally computer-controlled triple quadrupole mass spectrometer system

    International Nuclear Information System (INIS)

    Wong, C.M.; Crawford, R.W.; Barton, V.C.; Brand, H.R.; Neufeld, K.W.; Bowman, J.E.

    1983-01-01

    A totally computer-controlled triple quadrupole mass spectrometer (TQMS) is described. It has a number of unique features not available on current commercial instruments, including: complete computer control of source and all ion axial potentials; use of dual computers for data acquisition and data processing; and capability for self-adaptive control of experiments. Furthermore, it has been possible to produce this instrument at a cost significantly below that of commercial instruments. This triple quadrupole mass spectrometer has been constructed using components commercially available from several different manufacturers. The source is a standard Hewlett-Packard 5985B GC/MS source. The two quadrupole analyzers and the quadrupole CAD region contain Balzers QMA 150 rods with Balzers QMG 511 rf controllers for the analyzers and a Balzers QHS-511 controller for the CAD region. The pulsed-positive-ion-negative-ion-chemical ionization (PPINICI) detector is made by Finnigan Corporation. The mechanical and electronics design were developed at LLNL for linking these diverse elements into a functional TQMS as described. The computer design for total control of the system is unique in that two separate LSI-11/23 minicomputers and assorted I/O peripherals and interfaces from several manufacturers are used. The evolution of this design concept from totally computer-controlled instrumentation into future self-adaptive or ''expert'' systems for instrumental analysis is described. Operational characteristics of the instrument and initial results from experiments involving the analysis of the high explosive HMX (1,3,5,7-Tetranitro-1,3,5,7-Tetrazacyclooctane) are presented

  2. Estimating the Efficiency of Phosphopeptide Identification by Tandem Mass Spectrometry

    Science.gov (United States)

    Hsu, Chuan-Chih; Xue, Liang; Arrington, Justine V.; Wang, Pengcheng; Paez Paez, Juan Sebastian; Zhou, Yuan; Zhu, Jian-Kang; Tao, W. Andy

    2017-06-01

    Mass spectrometry has played a significant role in the identification of unknown phosphoproteins and sites of phosphorylation in biological samples. Analyses of protein phosphorylation, particularly large scale phosphoproteomic experiments, have recently been enhanced by efficient enrichment, fast and accurate instrumentation, and better software, but challenges remain because of the low stoichiometry of phosphorylation and poor phosphopeptide ionization efficiency and fragmentation due to neutral loss. Phosphoproteomics has become an important dimension in systems biology studies, and it is essential to have efficient analytical tools to cover a broad range of signaling events. To evaluate current mass spectrometric performance, we present here a novel method to estimate the efficiency of phosphopeptide identification by tandem mass spectrometry. Phosphopeptides were directly isolated from whole plant cell extracts, dephosphorylated, and then incubated with one of three purified kinases—casein kinase II, mitogen-activated protein kinase 6, and SNF-related protein kinase 2.6—along with 16O4- and 18O4-ATP separately for in vitro kinase reactions. Phosphopeptides were enriched and analyzed by LC-MS. The phosphopeptide identification rate was estimated by comparing phosphopeptides identified by tandem mass spectrometry with phosphopeptide pairs generated by stable isotope labeled kinase reactions. Overall, we found that current high speed and high accuracy mass spectrometers can only identify 20%-40% of total phosphopeptides primarily due to relatively poor fragmentation, additional modifications, and low abundance, highlighting the urgent need for continuous efforts to improve phosphopeptide identification efficiency. [Figure not available: see fulltext.

  3. Characterization of ornidazole metabolites in human bile after intraveneous doses by ultraperformance liquid chromatography/quadrupole time-of-flight mass spectrometry

    Directory of Open Access Journals (Sweden)

    Jiangbo Du

    2012-04-01

    Full Text Available Ultraperformance liquid chromatography/quadrupole time-of-flight mass spectrometry (UPLC/Q-TOF MS was used to characterize ornidazole metabolites in human bile after intravenous doses. A liquid chromatography tandem mass spectrometry (LC–MS/MS assay was developed for the determination of the bile level of ornidazole. Bile samples, collected from four patients with T-tube drainage after biliary tract surgery, were prepared by protein precipitation with acetonitrile before analysis. A total of 12 metabolites, including 10 novel metabolites, were detected and characterized. The metabolites of ornidazole in human bile were the products of hydrochloride (HCl elimination, oxidative dechlorination, hydroxylation, sulfation, diastereoisomeric glucuronation, and substitution of NO2 or Cl atom by cysteine or N-acetylcysteine, and oxidative dechlorination followed by further carboxylation. The bile levels of ornidazole at 12 h after multiple intravenous infusions were well above its minimal inhibitory concentration for common strains of anaerobic bacteria.

  4. Comparison of ion coupling strategies for a microengineered quadrupole mass filter.

    Science.gov (United States)

    Wright, Steven; Syms, Richard R A; O'Prey, Shane; Hong, Guodong; Holmes, Andrew S

    2009-01-01

    The limitations of conventional machining and assembly techniques require that designs for quadrupole mass analyzers with rod diameters less than a millimeter are not merely scale versions of larger instruments. We show how silicon planar processing techniques and microelectromechanical systems (MEMS) design concepts can be used to incorporate complex features into the construction of a miniature quadrupole mass filter chip that could not easily be achieved using other microengineering approaches. Three designs for the entrance and exit to the filter consistent with the chosen materials and techniques have been evaluated. The differences between these seemingly similar structures have a significant effect on the performance. Although one of the designs results in severe attenuation of transmission with increasing mass, the other two can be scanned to m/z = 400 without any corruption of the mass spectrum. At m/z = 219, the variation in the transmission of the three designs was found to be approximately four orders of magnitude. A maximum resolution of M/DeltaM = 87 at 10% peak height has been achieved at m/z = 219 with a filter operated at 6 MHz and constructed using rods measuring (508 +/- 5) microm in diameter.

  5. Determination of 4-Methylimidazole in Ammonia Caramel Using Gas Chromatography–Tandem Mass Spectrometry (GC-MS/MS

    Directory of Open Access Journals (Sweden)

    Martyna N. Wieczorek

    2018-01-01

    Full Text Available One of Maillard reaction products formed in the production of ammonia caramel is 4(5-methylimidazole (4-MeI classified as carcinogen. A method of 4-MeI determination based on ion-pair extraction and derivatisation with isobutyl chloroformate with subsequent gas chromatography-tandem mass spectrometry analysis was proposed. Tandem mass spectrometry was applied to reduce the influence of matrix and increase the selectivity and sensitivity of the method. Triple quadrupole GC-MS system was used for this study. The collision energies were optimized for MRM mode. The detection (LOD and quantification limits (LOQ of the elaborated method were 17 and 37.8 μg kg−1, respectively, repeatability was <15% RSD for analyzed caramel samples, and the recovery for 4-MeI was 101%. Comparison of MS/MS with SIM detection on the same instrument proved almost 30 times lower LODs achieved by tandem mass spectrometry compared to SIM. Described method can be routinely used for monitoring 4-MeI as a quality and safety marker in the production of ammonia caramel.

  6. Portable, remotely operated, computer-controlled, quadrupole mass spectrometer for field use

    International Nuclear Information System (INIS)

    Friesen, R.D.; Newton, J.C.; Smith, C.F.

    1982-04-01

    A portable, remote-controlled mass spectrometer was required at the Nevada Test Site to analyze prompt post-event gas from the nuclear cavity in support of the underground testing program. A Balzers QMG-511 quadrupole was chosen for its ability to be interfaced to a DEC LSI-11 computer and to withstand the ground movement caused by this field environment. The inlet system valves, the pumps, the pressure and temperature transducers, and the quadrupole mass spectrometer are controlled by a read-only-memory-based DEC LSI-11/2 with a high-speed microwave link to the control point which is typically 30 miles away. The computer at the control point is a DEC LSI-11/23 running the RSX-11 operating system. The instrument was automated as much as possible because the system is run by inexperienced operators at times. The mass spectrometer has been used on an initial field event with excellent performance. The gas analysis system is described, including automation by a novel computer control method which reduces operator errors and allows dynamic access to the system parameters

  7. Tandem mass spectrometric studies of lanthanum-α-hydroxycarboxylate complexes

    International Nuclear Information System (INIS)

    Kumar, Pranaw; Telmore, V.M.; Jaison, P.G.; Sadhu, Biswajit; Sundararajan, Mahesh

    2017-01-01

    The complexation of lanthanides with hydroxycarboxylic acids is important to understand its separation behavior on liquid chromatography. Electrospray ionization mass spectrometry (ESI-MS) being the soft ionization technique is known for studying the speciation and stoichiometry of metal ligand species. The gentle ionization process of this technique is well suited for transferring the species from solution to gas phase with the retention of stoichiometry. The use of tandem mass spectrometric application has been utilized for studying the path of dissociation. The possible pathways of fragmentation and its geometry have been explained by using the density functional theory (OFT) in the gas phase. Present work describes integrated DFT and tandem mass spectrometric studies of La with α-hydroxyisobutyric acid (HIBA) along with their dissociation studies. In this study, unusual elimination of -CO with the loss of m/z 28 from the complex was observed. This fragmentation resulted the conversion of HIBA into acetone in the fragmented product. The possible fragmentation pathways with the energetic were identified

  8. Instruction manual for ORNL tandem high abundance sensitivity mass spectrometer

    International Nuclear Information System (INIS)

    Smith, D.H.; McKown, H.S.; Chrisite, W.H.; Walker, R.L.; Carter, J.A.

    1976-06-01

    This manual describes the physical characteristics of the tandem mass spectrometer built by Oak Ridge National Laboratory for the International Atomic Energy Agency. Specific requirements met include ability to run small samples, high abundance sensitivity, good precision and accuracy, and adequate sample throughput. The instrument is capable of running uranium samples as small as 10 -12 g and has an abundance sensitivity in excess of 10 6 . Precision and accuracy are enhanced by a special sweep control circuit. Sample throughput is 6 to 12 samples per day. Operating instructions are also given

  9. Characterization of the limonene oxidation products with liquid chromatography coupled to the tandem mass spectrometry

    Science.gov (United States)

    Witkowski, Bartłomiej; Gierczak, Tomasz

    2017-04-01

    Composition of the secondary organic aerosol (SOA) generated during ozonolysis of limonene was investigated with liquid chromatography coupled to the negative electrospray ionization (ESI), quadrupole tandem mass spectrometry (MS/MS) as well as high resolution Time-of-Flight mass spectrometry. Aerosol was generated in the flow-tube reactor. HR-MS/MS analysis allowed for proposing structures for the several up-to-date unknown limonene oxidation products. In addition to the low MW limonene oxidation products, significant quantities of oligomers characterized by elemental compositions: C19H30O5, C18H28O6, C19H28O7, C19H30O7 and C20H34O9 were detected in the SOA samples. It was concluded that these compounds are most likely esters, aldol reaction products and/or hemiacetals. In addition to detailed study of the limonene oxidation products, the reaction time as well as initial ozone concentration impact on the limonene SOA composition was investigated. The relative intensities of the two esters of the limonic acid and 7-hydroxy limononic acid increased as a result of lowering the initial ozone concentration and shortening the reaction time, indicating that esterification may be an important oligomerization pathway during limonene SOA formation.

  10. Quantitative analysis of mitragynine in human urine by high performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Lu, Shijun; Tran, Buu N; Nelsen, Jamie L; Aldous, Kenneth M

    2009-08-15

    Mitragynine is the primary active alkaloid extracted from the leaves of Mitragyna speciosa Korth, a plant that originates in South-East Asia and is commonly known as kratom in Thailand. Kratom has been used for many centuries for their medicinal and psychoactive qualities, which are comparable to that of opiate-based drugs. Kratom abuse can lead to a detectable content of mitragynine residue in urine. Ultra trace amount of mitragynine in human urine was determined by a high performance liquid chromatography coupled to an electrospray tandem mass spectrometry (HPLC-ESI/MS/MS). Mitragynine was extracted by methyl t-butyl ether (MTBE) and separated on a HILIC column. The ESI/MS/MS was accomplished using a triple quadrupole mass spectrometer in positive ion detection and multiple reactions monitoring (MRM) mode. Ajmalicine, a mitragynine's structure analog was selected as internal standard (IS) for method development. Quality control (QC) performed at three levels 0.1, 1 and 5 ng/ml of mitragynine in urine gave mean recoveries of 90, 109, and 98% with average relative standard deviation of 22, 12 and 16%, respectively. The regression linearity of mitragynine calibration ranged from 0.01 to 5.0 ng/ml was achieved with correlation coefficient greater than 0.995. A detection limit of 0.02 ng/ml and high precision data within-day and between days analysis were obtained.

  11. Accurate Identification of Deamidated Peptides in Global Proteomics using a Quadrupole Orbitrap Mass Spectrometer

    Science.gov (United States)

    Nepomuceno, Angelito I.; Gibson, Radiance J.; Randall, Shan M.; Muddiman, David C.

    2014-01-01

    Deamidation of asparagine and glutamine residues is a common post-translational modification. Researchers often rely on mass spectrometric based proteomic techniques for the identification of these post-translational sites. Mass spectral analysis of deamidated peptides is complicated and often misassigned due to overlapping 13C peak of the amidated form with the deamidated monoisotopic peak; these two peaks are only separated by 19.34 mDa. For proper assignment it is inherently important to use a mass spectrometer with high mass measurement accuracy and high resolving power. Herein, mouse brain tissue lysate was prepared using filter-aided sample preparation (FASP) method and Stage Tip fractionation followed by analysis on a nanoLC coupled to a quadrupole orbitrap (Q-Exactive) mass spectrometer to accurately identify more than 5400 proteins. Mass spectral data was processed using MASCOT and ProteoIQ for accurate identification of peptides and proteins. MASCOT search values for precursor and MS/MS mass tolerances were investigated, and it was determined data searched with greater than 5 ppm precursor mass tolerance resulted in the misassignment of deamidated peptides. Peptides that were identified with a mass measurement accuracy of ± 5 ppm were correctly assigned. PMID:24289162

  12. Determination of olanzapine in whole blood using simple protein precipitation and liquid chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Marie Katrine Klose; Johansen, Sys Stybe

    2009-01-01

    A simple, sensitive, and reproducible liquid chromatography-tandem mass spectrometry method has been developed and validated for the quantification of the antipsychotic drug olanzapine in whole blood using dibenzepine as internal standard (IS). After acidic methanol-induced protein precipitation...... of the whole blood samples, olanzapine and IS were chromatographed on a reversed-phase Zorbax Extend-C(18)-column at pH 9.0. Quantification was performed on a triple-quadrupole mass spectrometer employing electrospray ionization technique operating in multiple reaction monitoring and positive ion mode. Total...... chromatographic run time was 15 min, and calibration curve was linear over the concentration range of 0.005 to 0.50 mg/kg olanzapine in whole blood. The method was validated for selectivity, matrix interference, recovery, linearity, limit of detection, limit of quantitation (LOQ), accuracy, precision...

  13. Determination of the isotopic ratio 235U/238U in UF6 using quadrupole mass spectrometry

    International Nuclear Information System (INIS)

    Kusahara, Helena Sueco

    1979-01-01

    In this work measurements of isotope ratios 235 U / 23 '8U in uranium hexafluoride are carried out using a quadrupole mass spectrometer. The operational parameters, which affect the final precision of the results, are standardized. Optimized procedures for the preparation of uranium hexafluoride samples by fluorination of uranium oxides using cobalt trifluoride method are established. Careful attention is given to the process of purification of uranium hexafluoride samples by fractional distillation. Adequate statistical methods for analysing the results obtained for single ratio measurements as well as the ratio ' of isotopic ratios of sample and standard ar.e developed. A precision of about 10 -4 for single ratio measurements and accuracy of about 0,3% for the ratio of sample and standard ratios are obtained. These results agree with the values which have been obtained using magnetic mass spectrometers. The procedures and methods established in this work can be employed in the systematic uranium isotope analysis in UF 6 form. (author)

  14. Structural Characterisation of Acetogenins from Annona muricata by Supercritical Fluid Chromatography Coupled to High-Resolution Tandem Mass Spectrometry.

    Science.gov (United States)

    Laboureur, Laurent; Bonneau, Natacha; Champy, Pierre; Brunelle, Alain; Touboul, David

    2017-11-01

    Acetogenins are plant polyketides known to be cytotoxic and proposed as antitumor candidates. They are also suspected to be alimentary neurotoxins. Their occurrence as complex mixtures renders their dereplication and structural identification difficult using liquid chromatography coupled to tandem mass spectrometry and efforts are required to improve the methodology. To develop a supercritical fluid chromatography (SFC) high-resolution tandem mass spectrometry method, involving lithium post-column cationisation, for the structural characterisation of Annonaceous acetogenins in crude extracts. The seeds of Annona muricata L. were extracted with methanol. Supercritical fluid chromatography of the extract, using a 2-ethylpyridine stationary phase column, was monitored using a high-resolution quadrupole time-of-flight mass spectrometer. Lithium iodide was added post-column in the make-up solvent. For comparison, the same extract was analysed using high-pressure liquid chromatography coupled to the same mass spectrometer, with a column based on solid core particles. Sensitivity was similar for both HPLC and SFC approaches. Retention behaviour and fragmentation pathways of three different isomer groups are described. A previously unknown group of acetogenins was also evidenced for the first time. The use of SFC-MS/MS allows the reduction of the time of analysis, of environmental impact and an increase in the chromatographic resolution, compared to liquid chromatography. This new methodology enlightened a new group of acetogenins, isomers of montanacin-D. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  15. Expert systems technology applied to instrument operation and data acquisition of a triple quadrupole mass spectrometer (TQMS)

    International Nuclear Information System (INIS)

    Wong, C.M.

    1984-01-01

    This presentation covers the work done at Lawrence Livermore National Laboratory by some computer programmers and analytical chemists specializing in mass spectrometry to develop an expert system for real-time tuning and optimization of operations of a triple quadrupole mass spectrometer (TQMS). This capability is important to increase the sensitivity possible for selected compounds throughout the entire mass range of the instrument, rather than settling for the traditional normalized calibration which lowers sensitivity at both ends of the mass scale

  16. A versatile triple radiofrequency quadrupole system for cooling, mass separation and bunching of exotic nuclei

    Science.gov (United States)

    Haettner, Emma; Plaß, Wolfgang R.; Czok, Ulrich; Dickel, Timo; Geissel, Hans; Kinsel, Wadim; Petrick, Martin; Schäfer, Thorsten; Scheidenberger, Christoph

    2018-02-01

    The combination of in-flight separation with a gas-filled stopping cell has opened a new field for experiments with exotic nuclei. For instance, at the SHIP/SHIPTRAP facility at GSI in Darmstadt high-precision mass measurements of rare nuclei have been successfully performed. In order to extend the reach of SHIPTRAP to exotic nuclei that are produced together with high rates of unwanted reaction products, a novel compact radio frequency quadrupole (RFQ) system has been developed. It implements ion cooling, identification and separation according to mass numbers and bunching capabilities. The system has a total length of one meter only and consists of an RFQ cooler, an RFQ mass filter and an RFQ buncher. A mass resolving power (FWHM) of 240 at a transmission efficiency of 90% has been achieved. The suppression of contaminants from neighboring masses by more than four orders of magnitude has been demonstrated at rates exceeding 106 ions/s. A longitudinal emittance of 0.45 eV μs has been achieved with the RFQ buncher, which will enable improved time-of-flight mass spectrometry downstream of the device. With this triple RFQ system the measurement of e.g. N= Z nuclides in the region up to tin will become possible at SHIPTRAP. The technology is also well suited for other rare-isotope facilities with experimental setups behind a stopping cell, such as the fragment separator FRS with the FRS Ion Catcher at GSI.

  17. Measurement of tamsulosin in human serum by liquid chromatography–tandem mass spectrometry☆

    Science.gov (United States)

    Upreti, Rita; Homer, Natalie Z.M.; Naredo, Gregorio; Cobice, Diego F.; Hughes, Katherine A.; Stewart, Laurence H.; Walker, Brian R.; Andrew, Ruth

    2013-01-01

    A simple, sensitive and robust method to extract tamsulosin from human serum, and quantify by liquid chromatography–tandem mass spectrometry (LC–MS/MS) was developed and validated and is applicable as a measure of compliance in clinical research. Tamsulosin was extracted from human serum (100 μL) via liquid–liquid extraction with methyl tert-butyl ether (2 mL) following dilution with 0.1 M ammonium hydroxide (100 μL), achieving 99.9% analyte recovery. Internal standard, d9-finasteride, was synthesised in-house. Analyte and internal standard were separated on an Ascentis® Express C18 (100 mm × 3 mm, 2.7 μm) column using a gradient elution with mobile phases methanol and 2 mM aqueous ammonium acetate (5:95, v/v). Total run-time was 6 min. Tamsulosin was quantified using a triple quadrupole mass spectrometer operated in multi-reaction-monitoring (MRM) mode using positive electrospray ionisation. Mass transitions monitored for quantitation were: tamsulosin m/z 409 → 228 and d9-finasteride m/z 382 → 318, with the structural formulae of ions confirmed by Fourier transform ion cyclotron resonance mass spectrometry (within 10 ppm). The limit of quantitation was 0.2 ng/mL, and the method was validated in the linear range 0.2–50 ng/mL with acceptable inter- and intra-assay precision and accuracy and stability suitable for routine laboratory practice. The method was successfully applied to samples taken from research volunteers in a clinical study of benign prostatic hyperplasia. PMID:23743242

  18. TANDEM

    Data.gov (United States)

    Federal Laboratory Consortium — The Tandem Van de Graaff facility provides researchers with beams of more than 40 different types of ions - atoms that have been stripped of their electrons. One of...

  19. Determination of polar pesticides in olive oil and olives by hydrophilic interaction liquid chromatography coupled to tandem mass spectrometry and high resolution mass spectrometry.

    Science.gov (United States)

    Nortes-Méndez, Rocío; Robles-Molina, José; López-Blanco, Rafael; Vass, Andrea; Molina-Díaz, Antonio; Garcia-Reyes, Juan F

    2016-09-01

    This article reports the development of two HPLC-MS methods for the determination of polar pesticides in olive oil and olive samples by hydrophilic interaction liquid chromatography (HILIC) separation followed by mass spectrometry detection with tandem mass spectrometry using a triple quadrupole instrument operated in multiple reaction monitoring mode (HILIC-MS/MS) or electrospray time-of-flight mass spectrometry (HILIC-TOFMS). The selected polar pesticides included in the study were: amitrol, cyromazine, diquat, paraquat, mepiquat, trimethylsulfonium (trimesium, glyphosate counterion) and fosetyl aluminium. The simple sample treatment procedure was based on liquid partitioning with methanol. The performance of the sample extraction was evaluated in terms of recovery rates and matrix effects in both olive oil and olives matrices. The results obtained for olive oil were satisfactory while, due to the high complexity of olives, poor recovery rates were obtained for the extraction of diquat, paraquat and amitrol, although with a reasonable precision enabling its use in routine analysis. Similarly, matrix effects were minor in the case of olive oil (ca. 20% suppression average), while significantly higher suppression was observed for olives (30-50% suppression average). The studied approaches were found to be useful for the determination of the pesticides studied in olive oil and olives with limits of quantitation below 5µgkg(-1) in most cases when tandem mass spectrometry was used, thus being in compliance with MRLs set by current EU regulation. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Calibration of the Quadrupole Mass Spectrometer of the Sample Analysis at Mars Instrument Suite

    Science.gov (United States)

    Mahaffy, P. R.; Trainer, M. G.; Eigenbrode, J. L.; Franz, H. B.; Stern, J. C.; Harpold, D.; Conrad, P. G.; Raaen, E.; Lyness, E.

    2011-01-01

    The SAM suite of instruments on the "Curiosity" Rover of the Mars Science Laboratory (MSL) is designed to provide chemical and isotopic analysis of organic and inorganic volatiles for both atmospheric and solid samples. The mission of the MSL investigations is to advance beyond the successful search for aqueous transformation in surface environments at Mars toward a quantitative assessment of habitability and preservation through a series of chemical and geological measurements. The SAM suite was delivered in December 2010 (Figure 1) to the Jet Propulsion Laboratory for integration into the Curiosity Rover. We previously outlined the range of SAM solid and gas calibrations implemented or planned and here we discuss a specific set of calibration experiments to establish the response of the SAM Quadrupole Mass Spectrometer (QMS) to the four most abundant gases in the Martian atmosphere CO2, N2, Ar, and O2, A full SAM instrument description and calibration report is presently in preparation.

  1. Compositional characterisation of rare earth magnet materials by glow discharge quadrupole mass spectrometry

    International Nuclear Information System (INIS)

    Reddy, M.A.; Shekhar, R.; Kumar, Sunil Jai

    2014-01-01

    In this paper, glow discharge quadrupole mass spectrometric (GD-QMS) studies on Sm-Pr-Co compound magnetic materials are reported. The composition of these magnetic materials produced from different manufacturing routes (imported, indigenous) was determined. The results are compared with the results obtained by an alternative analytic technique, inductively coupled plasma atomic emission spectrometry (ICP-AES), after complete dissolution of the material in the appropriate acids. For perfectly homogeneous material both the wet chemical method and direct solid analysis method should give the same result. A close examination of both the results indicates that for imported materials the values obtained by wet chemical method and direct solid method are in close agreement. This indicates that the imported (solid) material is highly homogeneous. For indigenous materials, it shows a large difference in the values of Co and Sm. This reveals that the solid material prepared is not as homogenous as the imported materials

  2. Gibbs free energy of formation of lanthanum rhodate by quadrupole mass spectrometer

    International Nuclear Information System (INIS)

    Prasad, R.; Banerjee, Aparna; Venugopal, V.

    2003-01-01

    The ternary oxide in the system La-Rh-O is of considerable importance because of its application in catalysis. Phase equilibria in the pseudo-binary system La 2 O 3 -Rh 2 O 3 has been investigated by Shevyakov et. al. Gibbs free energy of LaRhO 3 (s) was determined by Jacob et. al. using a solid state Galvanic cell in the temperature range 890 to 1310 K. No other thermodynamic data were available in the literature. Hence it was decided to determine Gibbs free energy of formation of LaRhO 3 (s) by an independent technique, viz. quadrupole mass spectrometer (QMS) coupled with a Knudsen effusion cell and the results are presented

  3. On the adge field effect of a quadrupole mass spectrometer on a charged particle beam

    International Nuclear Information System (INIS)

    Usacheva, T.V.; Kuz'min, A.F.

    1982-01-01

    Functional parameter dependences of charged particle beam transport in the edge field of a quadrupole mass spectrometer on the parameters of the spectrometer and the potential are presented, making an assumption of linear potential change in the direction parallel to the spectrometer electrodes. Obtained are: inequality, convenient for the passage through the edge field of ion beams with point source vertex and axis of symmetry, parallel to the spectrometer electrodes; inequality, giving the upper bound of maximal ion approach to the spectrometer electrodes in the edge field; inequality, estimating the maximum value of charged particle velocity on a plane, being perpendicular to the spectrometer electrodes at the particle passage through the edge field. The inequalities obtained have been determined the relationships among the ion beam, the spectrometer and the edge field parameters

  4. Fast atom bombardment tandem mass spectrometry of carotenoids

    Energy Technology Data Exchange (ETDEWEB)

    van Breeman, R.B. [Univ. of Illinois, Chicago, IL (United States); Schmitz, H.H.; Schwartz, S.J. [North Carolina State Univ., Raleigh, NC (United States)

    1995-02-01

    Positive ion fast atom bombardment (FAB) tandem mass spectrometry (MS-MS) using a double-focusing mass spectrometer with linked scanning at constant B/E and high-energy collisionally activated dissociation (CAD) was used to differentiate 17 different cartenoids, including {beta}-apo-8{prime}- carotenal, astaxanthin, {alpha}-carotene, {beta}-carotene, {gamma}-carotene, {zeta}-carotene, canthaxanthin, {beta}-cryptoxanthin, isozeaxanthin bis (pelargonate), neoxanthin, neurosporene, nonaprene, lutein, lycopene, phytoene, phytofluene, and zeaxanthin. The carotenoids were either synthetic or isolated from plant tissues. The use of FAB ionization minimized degradation or rearrangement of the carotenoid structures due to the inherent thermal instability generally ascribed to these compounds. Instead of protonated molecules, both polar xanthophylls and nonpolar carotenes formed molecular ions, M{sup {center_dot}+}, during FAB ionization. Following collisionally activated dissociation, fragment ions of selected molecular ion precursors showed structural features indicative of the presence of hydroxyl groups, ring systems, ester groups, and aldehyde groups and the extent of aliphatic polyene conjugation. The fragmentation patterns observed in the mass spectra herein may be used as a reference for the structural determination of carotenoids isolated from plant and animal tissues. 18 refs., 4 figs.

  5. Simulation of Two Dimensional Electrophoresis and Tandem Mass Spectrometry for Teaching Proteomics

    Science.gov (United States)

    Fisher, Amanda; Sekera, Emily; Payne, Jill; Craig, Paul

    2012-01-01

    In proteomics, complex mixtures of proteins are separated (usually by chromatography or electrophoresis) and identified by mass spectrometry. We have created 2DE Tandem MS, a computer program designed for use in the biochemistry, proteomics, or bioinformatics classroom. It contains two simulations--2D electrophoresis and tandem mass spectrometry.…

  6. Quantification, confirmation and screening capability of UHPLC coupled to triple quadrupole and hybrid quadrupole time-of-flight mass spectrometry in pesticide residue analysis.

    Science.gov (United States)

    Grimalt, Susana; Sancho, Juan V; Pozo, Oscar J; Hernández, Félix

    2010-04-01

    The potential of three mass spectrometry (MS) analyzers (triple quadrupole, QqQ; time of flight, TOF; and quadrupole time of flight, QTOF) has been investigated and compared for quantification, confirmation and screening purposes in pesticide residue analysis of fruit and vegetable samples. For this purpose, analytical methodology for multiresidue determination of 11 pesticides, taken as a model, has been developed and validated in nine food matrices for the three mass analyzers coupled to ultra high pressure liquid chromatography. In all cases, limits of quantification around 0.01 mg/kg were reached, fulfilling the most restrictive case of baby-food analysis. Regarding absolute sensitivity, the lower limits of detection were obtained, as expected, for QqQ (100 fg), whereas slightly higher limits (300 fg) were obtained for both TOF and QTOF. Confirmative capacity of each analyzer was studied for each analyte based on the identification points (IPs) criterion, useful for a comprehensive comparison. QTOF mass analyzer showed the highest confirmatory capacity, although QqQ normally led to sufficient number of IPs, even at lower concentration levels. The potential of TOF MS was also investigated for screening purposes. To this aim, around 50 commercial fruits and vegetables samples were analyzed, searching for more than 400 pesticides. TOF MS proved to be an attractive analytical tool for rapid detection and reliable identification of a large number of pesticides thanks to the full spectrum acquisition at accurate mass with satisfactory sensitivity. This process is readily boosted when combined with specialized software packages, together with theoretical exact mass databases. Several pesticides (e.g. carbendazim in citrus and indoxacarb in grape) were detected in the samples. Further unequivocal confirmation of the identity was performed using reference standards and/or QTOF MS/MS experiments. Copyright 2010 John Wiley & Sons, Ltd.

  7. Gas chromatographic quadrupole time-of-flight full scan high resolution mass spectrometric screening of human urine in antidoping analysis

    NARCIS (Netherlands)

    Abushareeda, Wadha; Lyris, Emmanouil; Kraiem, Suhail; Wahaibi, Aisha Al; Alyazidi, Sameera; Dbes, Najib; Lommen, Arjen; Nielen, Michel; Horvatovich, Peter L.; Alsayrafi, Mohammed; Georgakopoulos, Costas

    2017-01-01

    This paper presents the development and validation of a high-resolution full scan (FS) electron impact ionization (EI) gas chromatography coupled to quadrupole Time-of-Flight mass spectrometry (GC/QTOF) platform for screening anabolic androgenic steroids (AAS) in human urine samples. The World

  8. Gas chromatographic quadrupole time-of-flight full scan high resolution mass spectrometric screening of human urine in antidoping analysis

    NARCIS (Netherlands)

    Abushareeda, Wadha; Lyris, Emmanouil; Kraiem, Suhail; Wahaibi, Aisha Al; Alyazidi, Sameera; Dbes, Najib; Lommen, Arjen; Nielen, Michel; Horvatovich, Peter L.; Alsayrafi, Mohammed; Georgakopoulos, Costas

    2017-01-01

    This paper presents the development and validation of a high-resolution full scan (FS) electron impact ionization (EI) gas chromatography coupled to quadrupole Time-of-Flight mass spectrometry (GC/QTOF) platform for screening anabolic androgenic steroids (AAS) in human urine samples. The World

  9. Characterization of lipopeptides produced by Bacillus licheniformis using liquid chromatography with accurate tandem mass spectrometry.

    Science.gov (United States)

    Favaro, Gabriella; Bogialli, Sara; Di Gangi, Iole Maria; Nigris, Sebastiano; Baldan, Enrico; Squartini, Andrea; Pastore, Paolo; Baldan, Barbara

    2016-10-30

    The plant endophyte Bacillus licheniformis, isolated from leaves of Vitis vinifera, was studied to individuate and characterize the presence of bioactive lipopeptides having amino acidic structures. Crude extracts of liquid cultures were analyzed by ultra-high-performance liquid chromatography (UHPLC) coupled to a quadrupole time-of-flight (QTOF) mass analyzer. Chromatographic conditions were optimized in order to obtain an efficient separation of the different isobaric lipopeptides, avoiding merged fragmentations of co-eluted isomeric compounds and reducing possible cross-talk phenomena. Composition of the amino acids was outlined through the interpretation of the fragmentation behavior in tandem high-resolution mass spectrometry (HRMS/MS) mode, which showed both common-class and peculiar fragment ions. Both [M + H](+) and [M + Na](+) precursor ions were fragmented in order to differentiate some isobaric amino acids, i.e. Leu/Ile. Neutral losses characteristic of the iso acyl chain were also evidenced. More than 90 compounds belonging to the classes of surfactins and lichenysins, known as biosurfactant molecules, were detected. Sequential LC/HRMS/MS analysis was used to identify linear and cyclic lipopeptides, and to single out the presence of a large number of isomers not previously reported. Some critical issues related to the simultaneous selection of different compounds by the quadrupole filter were highlighted and partially solved, leading to tentative assignments of several structures. Linear lichenysins are described here for the first time. The approach was proved to be useful for the characterization of non-target lipopeptides, and proposes a rationale MS experimental scheme aimed to investigate the difference in amino acid sequence and/or in the acyl chain of the various congeners, when standards are not available. Results expanded the knowledge about production of linear and cyclic bioactive compounds from Bacillus licheniformis, clarifying the

  10. Isotopic dependence of the giant quadrupole resonance in the stable even-mass molybdenum nuclei

    International Nuclear Information System (INIS)

    Moalem, A.; Gaillard, Y.; Bemolle, A.M.; Buenerd, M.; Chauvin, J.; Duhamel, G.; Lebrun, D.; Martin, P.; Perrin, G.; de Saintignon, P.

    1979-01-01

    Inelastic scattering of 110 MeV 3 He particles is used to probe the quadrupole strength in the even Mo isotopes. The peak position of the giant quadrupole resonance is found to decrease more rapidly than predicted by the A/sup -1/3/ law, a behavior very similar to that exhibited by the photonuclear giant dipole resonance. The width and strength of the giant quadrupole resonance are practically constant in 92 Mo through 100 Mo

  11. Characterization of cationic glycoporphyrins by electrospray tandem mass spectrometry.

    Science.gov (United States)

    Silva, Eduarda M P; Serra, Vanda Vaz; Ribeiro, Anderson O; Tomé, João P C; Domingues, Pedro; Faustino, M Amparo F; Neves, M Graça P M S; Tomé, Augusto C; Cavaleiro, José A S; Ferrer-Correia, António J; Iamamoto, Yassuko; Domingues, M Rosário M

    2006-01-01

    Novel cationic porphyrin derivatives having a galactose or a bis(isopropylidene)galactose unit linked directly to a pyridine or to an aminophenyl group were characterized by electrospray tandem mass spectrometry (ESI-MS/MS). The electrospray mass spectra (ESI-MS) show the M(+) ions, since these porphyrins are already monocharged in solution. The fragmentation of these ions under ESI-MS/MS conditions was studied and it was found that elimination of the sugar residue as a radical (-163 or -243 Da) is a common fragmentation pathway. Loss of the sugar unit as a neutral fragment (-162 or -242 Da) and cross-ring fragmentations typical of glyco-derivatives are also observed for the pyridinium glycoporphyrins, but they are absent in the case of ammonium glycoporphyrins. The cationic beta-pyridiniumvinyl porphyrins show an atypical fragmentation due to the cleavage of the C(5)-C(6) bond of the sugar unit. Overall, the different patterns of fragmentation observed in the ESI-MS/MS spectra of the sugar pyridinium porphyrins and of the sugar ammonium phenyl porphyrins can give important information about the type of spacer between the porphyrin and the sugar unit. Copyright (c) 2006 John Wiley & Sons, Ltd.

  12. Screening of carnitine and biotin deficiencies on tandem mass spectrometry.

    Science.gov (United States)

    Hagiwara, Shin-Ichiro; Kubota, Mitsuru; Nambu, Ryusuke; Kagimoto, Seiichi

    2017-04-01

    It is important to assess pediatric patients for nutritional deficiency when they are receiving specific interventions, such as enteral feeding. We focused on measurement of C0 and 3-hydroxyisovalerylcarnitine (C5-OH) with tandem mass spectrometry (MS/MS), which is performed as part of the newborn mass screening. The purpose of this study was to investigate the usefulness of MS/MS for screening carnitine and biotin deficiencies. Forty-two children (24 boys, 18 girls) were enrolled between December 2013 and December 2015. Blood tests, including measurement of serum free carnitine via the enzyme cycling method, and acylcarnitine analysis on MS/MS of dried blood spot (DBS), were performed for the evaluation of nutrition status. Median patient age was 2 years (range, 2 months-14 years). Mean serum free carnitine was 41.8 ± 19.2 μmol/L. In six of the 42 patients, serum free carnitine was 1.00 nmol/L. Therapy-resistant eczema was improved by treatment with additional biotin and a non-hydrolyzed formula. C0 and C5-OH, measured on MS/MS of DBS, were useful for screening carnitine and biotin deficiencies. © 2016 Japan Pediatric Society.

  13. Rapid comparison of diacetylmorphine on banknotes by tandem mass spectrometry.

    Science.gov (United States)

    Ebejer, Karl A; Brereton, Richard G; Carter, James F; Ollerton, Samantha L; Sleeman, Richard

    2005-01-01

    A procedure is described for the determination of the distribution of the contamination of banknotes with controlled drugs using tandem mass spectrometry. The method is illustrated using diacetylmorphine, which is the major active component of heroin. A series of banknotes is introduced into the mass spectrometer and the intensities of two product ions (m/z 328 and 268) derived from the precursor protonated molecule (m/z 370) are recorded. A banknote is considered contaminated if it shows a significant peak for both product ions, and if the ratio of intensities of these two peaks falls within accepted limits. The distribution of diacetylmorphine on sterling banknotes taken from general circulation within the UK can be modelled by an arcsin (square root) transformation of the data or by a log transformation of the data with a higher proportion of contamination. The two models were found to be in close agreement, predicting an upper limit (at 99.9% confidence) of contamination on banknotes from general circulation between 9 and 10%. The percentage contamination in a case study was calculated and compared to the background distribution using the two models proposed. This comparison revealed that the contamination present in the case study was inconsistent with that present on banknotes in general circulation. (c) 2005 John Wiley & Sons, Ltd.

  14. System assessment and calibrations of the Knudsen effusion quadrupole mass spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Jintao; Furukawa, Tomohiro [Japan Nuclear Cycle Development Inst., Oarai, Ibaraki (Japan). Oarai Engineering Center

    2000-08-01

    A vapor pressure measurement instrument was set up by utilizing the Microvision Plus (LM70)' quadrupole mass spectrometer combined with the Knudsen vapor effusion cell. The purpose of the vapor pressure measurement is to obtain reliable thermodynamic data of sodium-iron complex compounds. Then, the behaviors of these compounds in various environmental conditions can be investigated in detail for analysis of sodium-leak related accidents in fast breeder reactors (FBR). Therefore, the reliability of the measurement system is of great importance. The following major procedures were made step by step. (1) Vertical alignment arrangements (2) Alignment of the ion mass in Q-mass analyzer (3) 'True' signal identification (4) Noise reducing (5) Determination of electron impact conditions (6) Sensitivity improvement by adjusting parameters (7) Temperature calibration (8) Vapor pressure calibration. First, special attention was paid to the mechanical settlements, exploration of the parameters' effects, calibrations of temperature and pressure. Second, the vapor pressure measurement system was optimized for the specific requirements based on the extensive investigation in this study. Furthermore, it is confirmed that the measured pressures of the standard vapor species (silver and lead) are accurate. Finally, identical result can be reproduced in the same conditions so that the measurement system is believed to be reliable for the future researches. (author)

  15. USING AN ACCURATE MASS, TRIPLE QUADRUPOLE MASS SPECTROMETER AND AN ION CORRELATION PROGRAM TO IDENTIFY COMPOUNDS

    Science.gov (United States)

    Most compounds are not found in mass spectral libraries and must be identified by other means. Often, compound identities can be deduced from the compositions of the ions in their mass spectra and review of the chemical literature. Confirmation is provided by mass spectra and r...

  16. Determination of caprolactam and 6-aminocaproic acid in human urine using hydrophilic interaction liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Wu, Ya-Hsueh; Wu, Ming-Ling; Lin, Chun-Chi; Chu, Wei-Lan; Yang, Chen-Chang; Lin, Robert Tate; Deng, Jou-Fang

    2012-02-15

    A simple and rapid assay based on hydrophilic interaction liquid chromatography with tandem mass spectrometry has been first developed and validated for simultaneous determination of caprolactam (CA) and 6-aminocaproic acid (6-ANCA) in human urine using 8-aminocaprylic acid as internal standard. A 20μL aliquot of urine was injected directly into the liquid chromatography tandem mass spectrometry (LC-MS-MS) system. The analytes were separated on a Phenomenex Luna HILIC column with gradient elution. Detection was performed on Triple Quadrupole LC-MS in positive ions multiple reaction monitoring mode using electrospray ionization. The calibration curves were linear (r(2)≥0.995) over the concentration range from 62.5 to 1250ng/mL for CA and 31.25 to 1000ng/mL for 6-ANCA. The detection limits of CA and 6-ANCA were 62.5 and 15.6ng/mL, respectively. The intra-day and inter-day precisions were within 8.7% and 9.9%, respectively. The intra-day and inter-day accuracy were between 5.3% and 3.5%, and between 6.1% and 6.6%, respectively. The method proved to be simple and time efficient, and was successfully applied to evaluate the kinetics of caprolactam in one unusual case of caprolactam poisoning. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. Rapid Determination of Imatinib in Human Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Application to a Pharmacokinetic Study

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Jeong Soo; Cho, Eun Gi; Huh, Wooseong; Ko, Jaewook; Jung, Jin Ah; Lee, Sooyoun [Samsung Medical Center, Seoul (Korea, Republic of)

    2013-08-15

    A simple, fast and robust analytical method was developed to determine imatinib in human plasma using liquid chromatography-tandem mass spectrometry with electrospray ionization in the positive ion mode. Imatinib and labeled internal standard were extracted from plasma with a simple protein precipitation. The chromatographic separation was performed using an isocratic elution of mobile phase involving 5.0 mM ammonium formate in water -5.0 mM ammonium formate in methanol (30:70, v/v) over 3.0 min on reversed-stationary phase. The detection was performed using a triple-quadrupole tandem mass spectrometer in multiple-reaction monitoring mode. The developed method was validated with lower limit of quantification of 10 ng/mL. The calibration curve was linear over 10-2000 ng/mL (R{sup 2} > 0.99). The method validation parameters met the acceptance criteria. The spiked samples and standard solutions were stable under conditions for storage and handling. The reliable method was successfully applied to real sample analyses and thus a pharmacokinetic study in 27 healthy Korean male volunteers.

  18. Structural elucidation of metolachlor photoproducts by liquid chromatography/high-resolution tandem mass spectrometry.

    Science.gov (United States)

    Nicol, Édith; Genty, Christophe; Bouchonnet, Stéphane; Bourcier, Sophie

    2015-12-15

    Metolachlor is one of the most intensively used chloroacetanilide herbicides in agriculture. It has been detected in water; consequently, under UV-visible irradiation, it can be transformed in degradation products (TPs). The structures of TPs were elucidated by liquid chromatography/high-resolution tandem mass spectrometry (LC/HR-MS/MS). The potential toxicities of these TPs were estimated by in silico tests. Aqueous solutions of metolachlor were irradiated in a self-made reactor equipped with a mercury vapor lamp. Analyses were carried out using high-performance liquid chromatography coupled to quadrupole time-of-flight (QTOF) mass spectrometer. High-resolution m/z measurements, MS/MS and isotopic labeling experiments allowed structural elucidation of metolachlor TPs. Their toxicities were estimated in silico, using the T.E.S.T. Ten major metolachlor photoproducts were characterized by LC/MS/MS after irradiation of metolachlor in aqueous solution. Elucidation of their chemical structures was identified using high-resolution measurements and MS/MS experiments. They resulted from the combination of dehalogenation, hydroxylation and cyclisation processes. The potential oral rat lethal dose (LD50) was assessed with QSAR tests for metolachlor and each photoproduct. Results indicate that most of the TPs are much more toxic than metolachlor. UV-vis irradiation of metolachlor in aqueous solution leads to the formation of ten photoproducts. QSAR estimations show that the location of added hydroxyl group(s) is of key relevance as regards to biological activity and that routine water analysis should take into account the TPs are more toxic than the parent molecule. Copyright © 2015 John Wiley & Sons, Ltd.

  19. Multi-elemental analysis of aqueous geochemical samples by quadrupole inductively coupled plasma-mass spectrometry (ICP-MS)

    Science.gov (United States)

    Wolf, Ruth E.; Adams, Monique

    2015-01-01

    Typically, quadrupole inductively coupled plasma-mass spectrometry (ICP-MS) is used to determine as many as 57 major, minor, and trace elements in aqueous geochemical samples, including natural surface water and groundwater, acid mine drainage water, and extracts or leachates from geological samples. The sample solution is aspirated into the inductively coupled plasma (ICP) which is an electrodeless discharge of ionized argon gas at a temperature of approximately 6,000 degrees Celsius. The elements in the sample solution are subsequently volatilized, atomized, and ionized by the ICP. The ions generated are then focused and introduced into a quadrupole mass filter which only allows one mass to reach the detector at a given moment in time. As the settings of the mass analyzer change, subsequent masses are allowed to impact the detector. Although the typical quadrupole ICP-MS system is a sequential scanning instrument (determining each mass separately), the scan speed of modern instruments is on the order of several thousand masses per second. Consequently, typical total sample analysis times of 2–3 minutes are readily achievable for up to 57 elements.

  20. Separation of polychlorinated dibenzo-p-dioxins/furans, non-ortho/mono/di/tri/tetra-ortho-polychlorinated biphenyls, and polybrominated diphenyl ethers groups of compounds prior to their determination with large volume injection gas chromatography-Quadrupole ion storage tandem mass spectrometry.

    Science.gov (United States)

    Roszko, Marek; Szymczyk, Krystyna; Jędrzejczak, Renata

    2013-10-17

    Polychlorinated dibenzo-p-dioxins/furans (PCDD/Fs), polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs) are important environmental contaminants. Their maximum legally allowable levels in food and environment are in the low pg g(-1) range. Therefore some highly selective and sensitive analytical methods must be used to determine them. Prior to final determination by GC/MS the cleaned-up samples have to be split into some fractions in view of large differences in concentrations of various analytes and existence of numerous chromatographic co-elutions (which in any case cannot be fully avoided). The aim of this study was to: (i) develop a robust, time-saving analytical method to isolate, clean-up and fractionate PCBs, PBDEs and PCDD/Fs prior to their determination with gas chromatography/ion trap mass spectrometry; (ii) assess method performance using laboratory validation data and some certified reference materials; (iii) use the developed method to assess PCB/PBDE/PCDD/F levels in samples of commercially available food. A combination of alumina, florisil, modified silica gel and two carbon columns were used for sample cleanup and fractionation. Separate fractions containing dioxins/furans, PBDE, non-ortho, mono-ortho and di-/tri-/tetra-ortho PCBs were obtained. The method statistical parameters were compatible with 1883/2006 EC Regulation (80-120%, RSD below 15%). The method performance was successfully used to evaluation of some real life food samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Sensitive helium leak detection in a deuterium atmosphere using a high-resolution quadrupole mass spectrometer

    International Nuclear Information System (INIS)

    Hiroki, S.; Abe, T.; Murakami, Y.

    1996-01-01

    In fusion machines, realizing a high-purity plasma is a key to improving the plasma parameters. Thus, leak detection is a necessary part of reducing the leak rate to a tolerable level. However, a conventional helium ( 4 He) leak detector is useless in fusion machines with a deuterium (D 2 ) plasma, because retained D particles on the first walls release D 2 for a long period and the released D 2 interferes with the signals from the leaked 4 He due to the near identical masses of 4.0026 u ( 4 He) and 4.0282 u (D 2 ). A high-resolution quadrupole mass spectrometer (HR-QMS) that we have recently developed, can detect a 4 He + population as small as 10 -4 peak in a D 2 atmosphere. Thus, the HR-QMS has been applied to detect 4 He leaks. To improve the minimum detectable limit of 4 He leak, a differentially pumped HR-QMS analyzer was attached to a chamber of the 4 He leak detector. In conclusion, the improved 4 He leak detector could detect 4 He leaks of the order of 10 -10 Pa · m 3 /s in a D 2 atmosphere. (Author)

  2. A fragmentation study of kaempferol using electrospray quadrupole time-of-flight mass spectrometry at high mass resolution

    Science.gov (United States)

    March, Raymond E.; Miao, Xiu-Sheng

    2004-02-01

    A mass spectrometric method based on the combined use of electrospray ionization, collision-induced dissociation and tandem mass spectrometry at high mass resolution has been applied to an investigation of the structural characterization of protonated and deprotonated kaempferol (3,5,7,4'-tetrahydroxyflavone). Low-energy product ion mass spectra of [M+H]+ ions showed simple fragmentations of the C ring that permitted characterization of the substituents in the A and B rings. In addition, four rearrangement reactions accompanied by losses of C2H2O, CHO[radical sign], CO, and H2O were observed. Low-energy product ion mass spectra of [M-H]- ions showed only four rearrangement reactions accompanied by losses of OH[radical sign], CO, CH2O, and C2H2O. The use of elevated cone voltages permitted observation of product ion mass spectra of selected primary and secondary fragment ions so that each fragment ion reported was observed as a direct product of its immediate precursor ion. Product ion mass spectra examined at high mass resolution allowed unambiguous determination of the elemental composition of fragment ions and resolution of two pairs of isobars. Fragmentation mechanisms and ion structures have been proposed.

  3. Collision-induced dissociation pathways of yeast sphingolipids and their molecular profiling in total lipid extracts: a study by quadrupole TOF and linear ion trap-orbitrap mass spectrometry

    DEFF Research Database (Denmark)

    Ejsing, Christer S.; Moehring, Thomas; Bahr, Ute

    2006-01-01

    The yeast Saccharomyces cerevisiae synthesizes three classes of sphingolipids: inositolphosphoceramides (IPCs), mannosyl-inositolphosphoceramides (MIPCs), and mannosyl-diinositolphosphoceramides (M(IP)2C). Tandem mass spectrometry of their molecular anions on a hybrid quadrupole time-of-flight (Qq......TOF) instrument produced fragments of inositol-containing head groups, which were specific for each lipid class. MS(n) analysis performed on a hybrid linear ion trap-orbitrap (LTQ Orbitrap) mass spectrometer with better than 3 ppm mass accuracy identified fragment ions specific for the amide-linked fatty acid...... and the long chain base moieties in individual molecular species. By selecting m/z of class-specific fragment ions for multiple precursor ion scanning, we profiled yeast sphingolipids in total lipid extracts on a QqTOF mass spectrometer. Thus, a combination of QqTOF and LTQ Orbitrap mass spectrometry lends...

  4. Investigation of cannabis biomarkers and transformation products in waters by liquid chromatography coupled to time of flight and triple quadrupole mass spectrometry.

    Science.gov (United States)

    Boix, Clara; Ibáñez, María; Bijlsma, Lubertus; Sancho, Juan V; Hernández, Félix

    2014-03-01

    11-Nor-9-carboxy-Δ(9)-tetrahydrocannabinol (THC-COOH) is commonly selected as biomarker for the investigation of cannabis consumption through wastewater analysis. The removal efficiency of THC-COOH in wastewater treatment plants (WWTPs) has been reported to vary between 31% and 98%. Accordingly, possible transformation products (TPs) of this metabolite might be formed during treatment processes or in receiving surface water under environmental conditions. In this work, surface water was spiked with THC-COOH and subjected to hydrolysis, chlorination and photo-degradation (both ultraviolet and simulated sunlight) experiments under laboratory-controlled conditions. One hydrolysis, eight chlorination, three ultraviolet photo-degradation and seven sunlight photo-degradation TPs were tentatively identified by liquid chromatography coupled to quadrupole time-of-flight mass spectrometer (LC-QTOF MS). In a subsequent step, THC-COOH and the identified TPs were searched in wastewater samples using LC coupled to tandem mass spectrometry (LC-MS/MS) with triple quadrupole. THC-COOH was found in all influent and effluent wastewater samples analyzed, although at significant lower concentrations in the effluent samples. The removal efficiency of WWTP under study was approximately 86%. Furthermore, THC-COOH was also investigated in several surface waters, and it was detected in 50% of the samples analyzed. Regarding TPs, none were found in influent wastewater, while one hydrolysis and five photo-degradation (simulated sunlight) TPs were detected in effluent and surface waters. The most detected compound, resulting from sunlight photo-degradation, was found in 60% of surface waters analyzed. This fact illustrates the importance of investigating these TPs in the aquatic environment. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Evaluation of relative isotopic abundance measurements in a quadrupole time-of-flight mass spectrometer for elemental composition determination of natural products in traditional Chinese medicine.

    Science.gov (United States)

    Wu, Zhi-Jun; Huo, Jia-Li; Chen, Jian-Zhong; Li, Na; Fang, Dong-Mei; Chen, Xiao-Zhen; Zhang, Guo-Lin; Wang, Jian-Hua; Xu, Xiao-Ying

    2013-01-01

    The relative isotopic abundance (RIA) measurement errors of a quadrupole time-of-flight (Q-ToF) instrument incorporating analog-to-digital converter detectors were systemically evaluated by stochastically collecting about 200 data in positive ion mass spectrometry (MS) mode. Errors varied with peak intensities at definite spectral acquisition rates but were very close, even if peak intensities changed sharply at different spectral acquisition rates with the same concentration. Intensity thresholds were systematically defined at 1 Hz of spectral acquisition rates. RIA measurement errors were also evaluated using peak area. It seemed that peak area was better adapted for the high-intensity ions while peak intensity was suited for very low-intensity ions. Several known compounds were selected for RIA measurements for product ions in tandem mass spectropmetry (MS/MS) mode. An extract of a representative traditional Chinese medicinal, Paederia scandens was analyzed with high-performance liquid chromatography-electrospray ionization-QToF-MS/MS. The unique elemental compositions of some compounds could not be identified even with exact masses and MS/MS spectra of measured and reference compounds. RIA errors, especially of (M+2)M(-1), provided vital information for determining the elemental composition.

  6. Quadrupole-time-of-flight mass spectrometry screening for synthetic cannabinoids in herbal blends.

    Science.gov (United States)

    Ibáñez, María; Bijlsma, Lubertus; van Nuijs, Alexander L N; Sancho, Juan V; Haro, Gonzalo; Covaci, Adrian; Hernández, Félix

    2013-06-01

    'Legal highs' are novel substances which are intended to elicit a psychoactive response. They are sold from 'head shops', the internet and from street suppliers and may be possessed without legal restriction. Several months ago, a 19-year-old woman came searching for medical treatment as she had health problems caused by smoking legal highs. The substances were sold as herbal blends in plastic bags under four different labels. In this work, samples of these herbal blends have been analysed to investigate the presence of psychoactive substances without any reference standard being available at the laboratory. A screening strategy for a large number of synthetic and natural cannabinoids has been applied based on the use of ultra-high pressure liquid chromatography coupled to quadrupole-time of flight mass spectrometry (UHPLC-QTOF MS) under MS(E) mode. A customized home-made database containing literature-based exact masses for parent and product ions of around 200 synthetic and natural cannabinoids was compiled. The presence of the (de)protonated molecule measured at its accurate mass was evaluated in the samples. When a peak was detected, collision-induced dissociation fragments and characteristic isotopic ions were also evaluated and used for tentative identification. After this tentative identification, four synthetic cannabinoids (JWH-081, JWH-250, JWH-203 and JWH-019) were unequivocally confirmed by subsequent acquisition of reference standards. The presence in the herbal blends of these synthetic cannabinoids might explain the psychotic and catatonic symptoms observed in the patient, as JWH compounds could act as potent agonists of CB1 and CB2 receptors located in the Limbic System and Basal ganglia of the human brain. Copyright © 2013 John Wiley & Sons, Ltd.

  7. Ultrasensitive leak detection during ultrahigh vacuum evacuation by quadrupole mass spectrometer

    International Nuclear Information System (INIS)

    Chen Xu; Huang Tianbin; Wang Ligong; Jin Qiji; Cha Liangzhen

    2006-01-01

    One must do ultrasensitive leak detection during ultrahigh-vacuum (UHV) evacuation, especially just before the device is sealed off from the vacuum system, to guarantee the longevity of the sealed high-vacuum or even UHV devices with small volume. A quadrupole mass spectrometer (QMS) with an UHV evacuation system can be used under accumulation mode to do the testing. Possible accumulate modes, as well as their advantages and shortcomings, are studied experimentally and discussed in this paper. We found that the opening action of the metal valve during accumulation mode always severely affects the height of the peak indicated by QMS and causes considerable errors. If we determine the leak rate by the peak area instead of the peak height, the situation is much improved. This method has proven quite useful in ensuring the tightness quality for complex sealed UHV devices with small volumes. Ultrasensitive leak detection has been carried out for such real evacuating devices, and a leak rate of 2x10 -14 Pa·m 3 /s was detected, which is far lower than its dynamic mode and the detection limit of the current advanced commercial leak detectors

  8. Multiple Reaction Monitoring for Direct Quantitation of Intact Proteins Using a Triple Quadrupole Mass Spectrometer

    Science.gov (United States)

    Wang, Evelyn H.; Combe, Peter C.; Schug, Kevin A.

    2016-05-01

    Methods that can efficiently and effectively quantify proteins are needed to support increasing demand in many bioanalytical fields. Triple quadrupole mass spectrometry (QQQ-MS) is sensitive and specific, and it is routinely used to quantify small molecules. However, low resolution fragmentation-dependent MS detection can pose inherent difficulties for intact proteins. In this research, we investigated variables that affect protein and fragment ion signals to enable protein quantitation using QQQ-MS. Collision induced dissociation gas pressure and collision energy were found to be the most crucial variables for optimization. Multiple reaction monitoring (MRM) transitions for seven standard proteins, including lysozyme, ubiquitin, cytochrome c from both equine and bovine, lactalbumin, myoglobin, and prostate-specific antigen (PSA) were determined. Assuming the eventual goal of applying such methodology is to analyze protein in biological fluids, a liquid chromatography method was developed. Calibration curves of six standard proteins (excluding PSA) were obtained to show the feasibility of intact protein quantification using QQQ-MS. Linearity (2-3 orders), limits of detection (0.5-50 μg/mL), accuracy (protein. Sensitivities for different proteins varied considerably. Biological fluids, including human urine, equine plasma, and bovine plasma were used to demonstrate the specificity of the approach. The purpose of this model study was to identify, study, and demonstrate the advantages and challenges for QQQ-MS-based intact protein quantitation, a largely underutilized approach to date.

  9. Long-term changes in the sensitivity of quadrupole mass spectrometers

    International Nuclear Information System (INIS)

    Blanchard, W.R.; McCarthy, P.J.; Dylla, H.F.; LaMarche, P.H.; Simpkins, J.E.

    1986-02-01

    We routinely use quadrupole mass spectrometers (QMS) to monitor vacuum conditions, gas purity, and plasma-wall interactions in the Tokamak Fusion Test Reactor (TFTR) at Princeton. Two QMS systems have been operating on TFTR continuously for a two-year period. Both QMS systems are absolutely calibrated at weekly intervals using a six-part standard gas mixture. The calibration procedure is based on the use of transfer standards (ion gauge and capacitance manometer) that are calibrated against a primary standard (spinning rotor gauge) on an external vacuum system. We have identified variations in the efficiency of the QMS ionizer and drifts in the sensitivity of the electron multiplier ion detector to be the major reasons for the observed changes in overall OMS sensitivity. Weekly variations in sensitivity greater than 100% have been observed following system bakeout at 150 0 C and with the use of rhenium filaments which were initially in the QMS ionizer. Operation of the QMS systems with tungsten filaments and at constant temperature has yielded more stable operation with weekly sensitivity changes generally being less than 10%. 7 refs., 7 figs

  10. Early synthetic dyes--a challenge for tandem mass spectrometry.

    Science.gov (United States)

    Lech, Katarzyna; Wilicka, Ewa; Witowska-Jarosz, Janina; Jarosz, Maciej

    2013-02-01

    The present study concerns identification of early yellow synthetic dyes from silk fibers taken from the 1930 spring color palette of the Lyon Dyers' Guild (La Chambre Syndicale des Teinturiers). The identification was based mainly on the electrospray ionization tandem mass spectrometry spectra obtained in the positive and negative ion modes. This technique was combined with high-performance liquid chromatography, which enabled separation of the analyzed compounds. Spectra registered for each of the examined synthetic dye allowed identification of their lost fragments. Moreover, isotopic profiles and exact measurements of m/z by using time of flight analyzer made possible to evaluate their elemental composition. In consequence, all obtained data, including UV-vis spectra, allowed to reconstruct molecular structures of examined colorants. Due to the lack of standards, the identification of the dyes was based only on the registration of fragment and quasi-molecular ions, what is rather uncommon in such analysis and means groping for the correct structure rather than proving signal identity by comparison with standards. Depending on substituents present in dye molecules, the lost fragments of the examined compounds involved SO(2), NO(•), NO(2)(•), CH(4), C(2)H(4), C(2)H(5)(•), C(2)H(6), CH(2)=N-CH(3), (CH(3))(2)NH, CH(2)= NH, CH(3)-NH(2), as well as CO and CO(2). The performed study led to identification of various colorants: rhodamine 6 G, rhodamine B, malachite green, quinoline yellow, picric acid and acetoquinone yellow 5JZ. Copyright © 2013 John Wiley & Sons, Ltd.

  11. Tandem Mass Spectrometry of Modified and Platinated Oligoribonucleotides

    Science.gov (United States)

    Nyakas, Adrien; Stucki, Silvan R.; Schürch, Stefan

    2011-05-01

    Therapeutic approaches for treatment of various diseases aim at the interruption of transcription or translation. Modified oligonucleotides, such as 2'- O-methyl- and methylphosphonate-derivatives, exhibit high resistance against cellular nucleases, thus rendering application for, e.g., antigene or antisense purposes possible. Other approaches are based on administration of cross-linking agents, such as cis-diamminedichloroplatinum(II) (cisplatin, DDP), which is still the most widely used anticancer drug worldwide. Due to the formation of 1,2-intrastrand cross links at adjacent guanines, replication of the double-strand is disturbed, thus resulting in significant cytotoxicity. Evidence for the gas-phase dissociation mechanism of platinated RNA is given, based on nano-electrospray ionization high-resolution multistage tandem mass spectrometry (MS n ). Confirmation was found by investigating the fragmentation pattern of platinated and unplatinated 2'-methoxy oligoribonucleotide hexamers and their corresponding methylphosphonate derivatives. Platinated 2'-methoxy oligoribonucleotides exhibit a similar gas-phase dissociation behavior as the corresponding DNA and RNA sequences, with the 3'-C-O bond adjacent to the vicinal guanines being cleaved preferentially, leading to wx-ion formation. By examination of the corresponding platinated methylphosphonate derivatives of the 2'-methoxy oligoribonucleotides, the key role of the negatively charged phosphate oxygen atoms in direct proximity to the guanines was proven. The significant alteration of fragmentation due to platination is demonstrated by comparison of the fragment ion patterns of unplatinated and platinated 2'- O-methyl- and 2'- O-methyl methylphosphonate oligoribonucleotides, and the results obtained by H/D exchange experiments.

  12. A modified quadrupole mass spectrometer with custom RF link rods driver for remote operation

    Science.gov (United States)

    Tashbar, P. W.; Nisen, D. B.; Moore, W. W., Jr.

    1973-01-01

    A commercial quadrupole residual gas analyzer system has been upgraded for operation at extended cable lengths. Operation inside a vacuum chamber for the standard quadrupole nude head is limited to approximately 2 m from its externally located rf/dc generator because of the detuning of the rf oscillator circuits by the coaxial cable reactance. The advance of long distance remote operation inside a vacuum chamber for distances of 45 and 60 m was made possible without altering the quadrupole's rf/dc generator circuit by employing an rf link to drive the quadrupole rods. Applications of the system have been accomplished for in situ space simulation thermal/vacuum testing of sophisticated payloads.

  13. Stable chlorine isotope analysis of chlorinated acetic acids using gas chromatography/quadrupole mass spectrometry.

    Science.gov (United States)

    Miska, Milena E; Shouakar-Stash, Orfan; Holmstrand, Henry

    2015-12-30

    The environmental occurrence of chlorinated acetic acids (CAAs) has been extensively studied, but the sources and transport are still not yet fully understood. A promising approach for source apportionment and process studies is the isotopic characterization of target compounds. We present the first on-line stable chlorine isotope analysis of CAAs by use of gas chromatography/quadrupole mass spectrometry (GC/qMS). Following approved procedures for concentration analysis, CAAs extracted into MTBE were methylated to GC-amenable methyl esters (mCAAs). These mCAAs were then analyzed by GC/qMS for their stable chlorine isotope composition using a sample/standard-bracketing approach (CAA standards in the range δ(37) Cl -6.3 to -0.2 ‰, Standard Mean Ocean Chloride). Cross-calibration of the herein presented method with off-line reference methods (thermal ionization and continuous-flow GC isotope ratio mass spectrometry; TI-MS and CF-GC/IRMS, respectively) shows good agreement between the methods (regression slope for GC/qMS vs reference method data sets: 0.92 ± 0.29). Sample amounts as small as 10 pmol Cl can herewith be analyzed with a precision of 0.1 to 0.4 ‰. This method should be useful for environmental studies of CAAs at ambient concentrations in precipitations (<0.06 to 100 nmol L(-1) ), surface waters (<0.2 to 5 nmol L(-1) ) and soil (<0.6 to 2000 nmol kg(-1) dry soil) where conventional off-line methods cannot be applied. Copyright © 2015 John Wiley & Sons, Ltd.

  14. Silicon isotope ratio measurements by inductively coupled plasma tandem mass spectrometry for alteration studies of nuclear waste glasses.

    Science.gov (United States)

    Gourgiotis, Alkiviadis; Ducasse, Thomas; Barker, Evelyne; Jollivet, Patrick; Gin, Stéphane; Bassot, Sylvain; Cazala, Charlotte

    2017-02-15

    High-level, long-lived nuclear waste arising from spent fuel reprocessing is vitrified in silicate glasses for final disposal in deep geologic formations. In order to better understand the mechanisms driving glass dissolution, glass alteration studies, based on silicon isotope ratio monitoring of 29 Si-doped aqueous solutions, were carried out in laboratories. This work explores the capabilities of the new type of quadrupole-based ICP-MS, the Agilent 8800 tandem quadrupole ICP-MS/MS, for accurate silicon isotope ratio determination for alteration studies of nuclear waste glasses. In order to avoid silicon polyatomic interferences, a new analytical method was developed using O 2 as the reaction gas in the Octopole Reaction System (ORS), and silicon isotopes were measured in mass-shift mode. A careful analysis of the potential polyatomic interferences on SiO + and SiO 2 + ion species was performed, and we found that SiO + ion species suffer from important polyatomic interferences coming from the matrix of sample and standard solutions (0.5M HNO 3 ). For SiO 2 + , no interferences were detected, and thus, these ion species were chosen for silicon isotope ratio determination. A number of key settings for accurate isotope ratio analysis like, detector dead time, integration time, number of sweeps, wait time offset, memory blank and instrumental mass fractionation, were considered and optimized. Particular attention was paid to the optimization of abundance sensitivity of the quadrupole mass filter before the ORS. We showed that poor abundance sensitivity leads to a significant shift of the data away from the Exponential Mass Fractionation Law (EMFL) due to the spectral overlaps of silicon isotopes combined with different oxygen isotopes (i.e. 28 Si 16 O 18 O + , 30 Si 16 O 16 O + ). The developed method was validated by measuring a series of reference solutions with different 29 Si enrichment. Isotope ratio trueness, uncertainty and repeatability were found to be

  15. Silicon isotope ratio measurements by inductively coupled plasma tandem mass spectrometry for alteration studies of nuclear waste glasses

    Energy Technology Data Exchange (ETDEWEB)

    Gourgiotis, Alkiviadis, E-mail: alkiviadis.gourgiotis@irsn.fr [Institut de Radioprotection et de Sûreté Nucléaire (IRSN), PRP-DGE/SRTG/LT2S, Fontenay-aux-Roses (France); Ducasse, Thomas [CEA, DEN, DTCD, SECM, F-30207 Bagnols-sur-Cèze (France); Barker, Evelyne [Institut de Radioprotection et de Sûreté Nucléaire (IRSN), PRP-DGE/SRTG/LT2S, Fontenay-aux-Roses (France); Jollivet, Patrick; Gin, Stéphane [CEA, DEN, DTCD, SECM, F-30207 Bagnols-sur-Cèze (France); Bassot, Sylvain; Cazala, Charlotte [Institut de Radioprotection et de Sûreté Nucléaire (IRSN), PRP-DGE/SRTG/LT2S, Fontenay-aux-Roses (France)

    2017-02-15

    High-level, long-lived nuclear waste arising from spent fuel reprocessing is vitrified in silicate glasses for final disposal in deep geologic formations. In order to better understand the mechanisms driving glass dissolution, glass alteration studies, based on silicon isotope ratio monitoring of {sup 29}Si-doped aqueous solutions, were carried out in laboratories. This work explores the capabilities of the new type of quadrupole-based ICP-MS, the Agilent 8800 tandem quadrupole ICP-MS/MS, for accurate silicon isotope ratio determination for alteration studies of nuclear waste glasses. In order to avoid silicon polyatomic interferences, a new analytical method was developed using O{sub 2} as the reaction gas in the Octopole Reaction System (ORS), and silicon isotopes were measured in mass-shift mode. A careful analysis of the potential polyatomic interferences on SiO{sup +} and SiO{sub 2}{sup +} ion species was performed, and we found that SiO{sup +} ion species suffer from important polyatomic interferences coming from the matrix of sample and standard solutions (0.5M HNO{sub 3}). For SiO{sub 2}{sup +}, no interferences were detected, and thus, these ion species were chosen for silicon isotope ratio determination. A number of key settings for accurate isotope ratio analysis like, detector dead time, integration time, number of sweeps, wait time offset, memory blank and instrumental mass fractionation, were considered and optimized. Particular attention was paid to the optimization of abundance sensitivity of the quadrupole mass filter before the ORS. We showed that poor abundance sensitivity leads to a significant shift of the data away from the Exponential Mass Fractionation Law (EMFL) due to the spectral overlaps of silicon isotopes combined with different oxygen isotopes (i.e. {sup 28}Si{sup 16}O{sup 18}O{sup +}, {sup 30}Si{sup 16}O{sup 16}O{sup +}). The developed method was validated by measuring a series of reference solutions with different {sup 29}Si

  16. [Rapid simultaneous determination of 53 beta-lactam antibiotics and their metabolites in milk by ultra-performance liquid chromatography coupled with triple quadrupole mass spectrometry].

    Science.gov (United States)

    Zhang, Xiuyao; Cai, Xinxin

    2014-07-01

    A rapid method for the determination of 53 beta-lactams and their metabolites residues in milk was developed by ultra-performance liquid chromatography-triple quadrupole mass spectrometry (UPLC-MS/MS). The method was based on protein precipitation by adding equal quantity of acetonitrile, followed by the ultra filtration of the extracts. The analysis of the residues was achieved on an ACQUITY BEH C18 column with gradient elution using mobile phases of 0.1% formic acid in water and acetonitrile. The analytes were detected by positive electrospray ionization tandem mass spectrometry in the multiple reaction monitoring (MRM) mode, and quantified by matrix-matched internal standard calibration. The cycle time of each analysis was 10 min. Under the optimum operation conditions, excellent linear dynamic range was observed from the quantification limits to 200 microg/kg with the correlation coefficients better than 0.991 1 for all the compounds. The average recoveries for all the beta-lactams and their metabolites ranged from 71% to 121% with the relative standard deviations of 1.7%-19% (n = 6). This method enabled the screening for more than 50 samples per day by one person and also showed good performance for quantitation, and allowed the determination of the beta-lactams and their metabolites residues in milk below the maximum residue levels (MRLs) according to the Bulletin No. 235 (2002) of Ministry of Agriculture, P. R. China and EU Regulation 2377/90/EC (2008 Revised).

  17. Application of Gas Chromatography Coupled to Quadrupole-Orbitrap Mass Spectrometry for Pesticide Residue Analysis in Cereals and Feed Ingredients.

    Science.gov (United States)

    Tienstra, Marc; Mol, Hans G J

    2018-03-01

    A method for residue analysis of pesticides and polychlorinated biphenyls in cereals and feed ingredients based on QuEChERS extraction, programmed temperature vaporizer large-volume injection, and GC with electron ionization (EI) quadrupole Orbitrap full-scan high-resolution MS (60 000 full width at half-maximum at m/z 200) has been developed. In addition to full-scan acquisition, simultaneous full-scan and selected-ion monitoring acquisition was used to improve detectability in incidental cases in which analytes coeluted with intense signals from coextractants. The method was successfully validated down to 10 µg/kg for a single commodity (wheat) using matrix-matched calibration, and for multiple-feed matrixes using standard addition. Identification according to European Union requirements was achieved in >90% of the analyte/matrix combinations, and suggestions for further increasing identification rates have been made. Performance characteristics were compared to an existing method for residue analysis based on GC with EI tandem MS (triple quadrupole).

  18. Gas chromatography–triple quadrupole mass spectrometry for the determination of atmospheric polychlorinated naphthalenes

    Energy Technology Data Exchange (ETDEWEB)

    Li, Fang [Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, No. 457 Zhongshan Road, Dalian 116023 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Jin, Jing [Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, No. 457 Zhongshan Road, Dalian 116023 (China); Sun, Xiaoli [Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, No. 457 Zhongshan Road, Dalian 116023 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Wang, Xueli; Li, Yun; Shah, Syed Mazhar [Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, No. 457 Zhongshan Road, Dalian 116023 (China); Chen, Jiping, E-mail: chenjp@dicp.ac.cn [Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, No. 457 Zhongshan Road, Dalian 116023 (China)

    2014-09-15

    Highlights: • Atmospheric PCNs were detected by isotope-dilution GC–MS/MS. • The pollution levels of PCNs covering from mono- to octa-CNs were investigated comprehensively in air samples. • The dioxin-like toxicity and human exposure levels of PCNs in air samples were estimated. - Abstract: Atmospheric polychlorinated naphthalenes (PCNs) ranging from mono-CNs to octa-CNs were detected using isotope-dilution gas chromatography coupled with triple quadrupole mass spectrometry (GC–MS/MS). The developed instrumental method was successfully applied to the determination of PCNs in technical products. It was observed that there were significant differences in concentrations, homologue profiles, chlorinated contents and total toxic equivalents (∑TEQs) of PCNs for four Halowax products. Subsequently, the validation of the analytical method was evaluated for the determination of PCNs in air samples in terms of method detection limit (MDL), recovery and matrix effect. The results demonstrated that this method could provide satisfactory sensitivity and adequate selectivity with lower cost. It was conducted to comprehensively evaluate the levels, composition patterns, ∑TEQs, and daily intake exposure of PCNs in indoor and outdoor air samples. Concentrations and ∑TEQs of PCNs in air samples ranged 47.7–832.7 pg m{sup −3} and 1.31–5.99 fg m{sup −3}, respectively, and the predominant homologues were di- and tri-CNs in the gas phase. The results indicated that this analytical method was useful for the accurate and specific evaluation of dioxin-like toxicity and human exposure levels of PCNs in the atmosphere.

  19. Differential fragmentation patterns of pectin oligogalacturonides observed by nanoelectrospray quadrupole ion-trap mass spectrometry using automated spectra interpretation

    DEFF Research Database (Denmark)

    Mutenda, Kudzai E; Matthiesen, Rune; Roepstorff, Peter

    2007-01-01

    Oligogalacturonides of different degrees of polymerization (DP) and methyl esterification (DE) were structurally analyzed by nanoESI quadrupole ion-trap mass spectrometry. The fragmentation patterns of the oligogalacturonides were compared using the program 'Virtual Expert Mass Spectrometrist...... oligogalacturonides, cross-ring fragmentation gives more structural information than glycosidic bond cleavage. One implication of this is that more structural information is obtained when analyzing methyl-esterified oligogalacturonides than non-methyl-esterified ones in an ion-trap instrument. This is of particular...

  20. Simultaneous determination of four water-soluble vitamins in fortified infant foods by ultra-performance liquid chromatography coupled with triple quadrupole mass spectrometry.

    Science.gov (United States)

    Lu, Baiyi; Ren, Yiping; Huang, Baifen; Liao, Wenqun; Cai, Zengxuan; Tie, Xiaowei

    2008-03-01

    A novel ultra-performance liquid chromatography electrospray ionization tandem triple quadrupole mass spectrometry method for the simultaneous determination of four water-soluble vitamins, including vitamin B5 (VB5), vitamin B8 (VB8), vitamin B9 (VB9), and vitamin B12 (VB12) in fortified infant foods is developed and validated. A reverse phase UPLC separation system consisting of a Waters ACQUITY UPLC BEH C-18 column (2.1 mm x 100 mm i.d., 1.7 microm) and a binary gradient acetonitrile-water mobile phase is applied for the separation of the four water-soluble vitamins. Formic acid is spiked into the mobile phase to enhance the ionization efficiency. Tandem MS-MS analysis is performed in multi-reaction monitoring mode (MRM). Product-ion traces at m/z 220.1 --> 89.9 for VB5, 245.1 --> 227.1 for VB8, 442.3 --> 295.2 for VB9, and 678.9 --> 147.0 for VB12 are used for quantitation of the corresponding vitamins, and traces at m/z 455.5 --> 308.0 are used for methotrexate (internal standard). Limits of quantitation (LOQs) are 0.016, 0.090, 0.020, and 0.019 microg/L for VB5, VB8, VB9, and VB12, respectively. Intra- and inter-day precisions for the determination of the four vitamins are better than 6.84% and 12.26% in relative standard deviations, and recoveries for the four vitamins are in the range of 86.0~101.5%. The developed approach is applied for the determination of the trace amounts of the vitamins in fortified milk powers and fortified rice powers.

  1. [Determination of propargite, tebuconazole and bromopropylate pesticide residues in Taiwan green jujubes by gas chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Zhang, Qun; Liu, Chunhua; Wu, Nancun; Wu, Xiaofang; Li, Shuhuai

    2014-08-01

    An analytical method was established for the determination of propargite, tebuconazole and bromopropylate in Taiwan green jujubes (Zizyphus mauritiana Lam) by gas chromatography-tandem mass spectrometry (GC-MS/MS). The sample was extracted with acetonitrile from the Taiwan green jujubes after treated with a homogenizer. The organic phase was then separated from water phase by adding NaCl. The extract was further purified on a carbon/ NH2 cartridge with elution solvents of acetonitrile/toluene (3:1, v/v). Finally, the target analytes were separated by a capillary gas chromatographic column SLB-5MS (30 m x 0. 25 mm x 0. 25 μm). A tandem quadrupole mass spectrometer operated in either full scan mode or in MS/MS mode for multiple reaction monitoring (MRM) was used for the qualitative and quantitative analysis of the constituents, respectively. The results showed that the average recoveries of the three pesticides ranged from 75. 8% to 103. 6% with the RSDs of 1. 7%-9. 3% at the spiking levels from 0.01 mg/kg to 0. 50 mg/kg (n= 5). The calibration curves showed good linearity in the range of 0.01-0.50 mg/kg, with the determination coefficients over 0.99 (R2>0.99). The limits of quantification (LOQs) were 0.01 mg/kg for propargite, tebuconazole and bromopropylate in Taiwan green jujubes. The method is available for the determination of propargite, tebuconazole and bromopropylate pesticide residues in Taiwan green jujubes.

  2. Determination of Platycodin D and Platycodin D3 in Rat Plasma Using Liquid Chromatography-Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Tae-Hyun Kim

    2014-01-01

    Full Text Available Platycodon grandiflorum has long been used as a traditional oriental medicine for respiratory disorder. Platycodin D (PD is known as the main component isolated from the root of PG. A simple and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS method has been developed and validated for the quantitation of PD in rat plasma. Quantitation was performed on a triple quadrupole mass spectrometer employing electrospray ionization and multiple reaction monitoring in positive ion mode. The total chromatographic run time was 4.0 min, and the calibration curves of PD were linear over the concentration range of 50–10,000 ng/mL in rat plasma. The coefficient of variation and relative error at five QC levels were 1.0 to 8.8% and 0.7 to 8.7%, respectively. After a single oral administration of 500 mg/kg and a single intravenous administration of 25 mg/kg of 3% PD extract (a PG extract including 3% of PD, platycodin D and platycodin D3 were detected and pharmacokinetic parameters were estimated. The oral bioavailability of platycodin D and platycodin D3 was 0.29% and 1.35% in rats at 500 mg/kg of 3% PD extract of PG, respectively. The present method can be applied to pharmacokinetic analysis of platycodins and platycosides of the PG.

  3. Liquid Chromatography with Tandem Mass Spectrometry: A Sensitive Method for the Determination of Dehydrodiisoeugenol in Rat Cerebral Nuclei

    Directory of Open Access Journals (Sweden)

    You-Bo Zhang

    2016-03-01

    Full Text Available A new liquid chromatography–tandem mass spectrometry (LC-MS/MS method is developed for the quantification of dehydrodiisoeugenol (DDIE in rat cerebral nuclei after single intravenous administration. DDIE and daidzein (internal standard were separated on a Diamonsil™ ODS C18 column with methanol–water containing 0.1% formic acid (81:19, v/v as a mobile phase. Detection of DDIE was performed on a positive electrospray ionization source using a triple quadrupole mass spectrometer. DDIE and daidzein were monitored at m/z 327.2→188.0 and m/z 255.0→199.2, respectively, in multiple reaction monitoring mode. This method enabled quantification of DDIE in various brain areas, including, cortex, hippocampus, striatum, hypothalamus, cerebellum and brainstem, with high specificity, precision, accuracy, and recovery. The data herein demonstrate that our new LC-MS/MS method is highly sensitive and suitable for monitoring cerebral nuclei distribution of DDIE.

  4. Atmospheric-pressure chemical ionization tandem mass spectrometry (APGC/MS/MS) an alternative to high-resolution mass spectrometry (HRGC/HRMS) for the determination of dioxins.

    Science.gov (United States)

    van Bavel, Bert; Geng, Dawei; Cherta, Laura; Nácher-Mestre, Jaime; Portolés, Tania; Ábalos, Manuela; Sauló, Jordi; Abad, Esteban; Dunstan, Jody; Jones, Rhys; Kotz, Alexander; Winterhalter, Helmut; Malisch, Rainer; Traag, Wim; Hagberg, Jessika; Ericson Jogsten, Ingrid; Beltran, Joaquim; Hernández, Félix

    2015-09-01

    The use of a new atmospheric-pressure chemical ionization source for gas chromatography (APGC) coupled with a tandem quadrupole mass spectrometry (MS/MS) system, as an alternative to high-resolution mass spectrometry (HRMS), for the determination of PCDDs/PCDFs is described. The potential of using atmospheric-pressure chemical ionization (APCI) coupled to a tandem quadrupole analyzer has been validated for the identification and quantification of dioxins and furans in different complex matrices. The main advantage of using the APCI source is the soft ionization at atmospheric pressure, which results in very limited fragmentation. APCI mass spectra are dominated by the molecular ion cluster, in contrast with the high energy ionization process under electron ionization (EI). The use of the molecular ion as the precursor ion in MS/MS enhances selectivity and, consequently, sensitivity by increasing the signal-to-noise ratios (S/N). For standard solutions of 2,3,7,8-TCDD, injections of 10 fg in the splitless mode on 30- or 60-m-length, 0.25 mm inner diameter (id), and 25 μm film thickness low-polarity capillary columns (DB5MS type), signal-to-noise (S/N) ratios of >10:1 were routinely obtained. Linearity was achieved in the region (correlation coefficient of r(2) > 0.998) for calibration curves ranging from 100 fg/μL to 1000 pg/μL. The results from a wide variety of complex samples, including certified and standard reference materials and samples from several QA/QC studies, which were previously analyzed by EI HRGC/HRMS, were compared with the results from the APGC/MS/MS system. Results between instruments showed good agreement both in individual congeners and toxic equivalence factors (TEQs). The data show that the use of APGC in combination with MS/MS for the analysis of dioxins has the same potential, in terms of sensitivity and selectivity, as the traditional HRMS instrumentation used for this analysis. However, the APCI/MS/MS system, as a benchtop system, is

  5. Selective separation and characterization of the stress degradation products of ondansetron hydrochloride by liquid chromatography with quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Talluri, Murali V N Kumar; Keshari, Kundan Kumar; Kalariya, Pradipbhai D; Srinivas, Ragampeta

    2015-05-01

    Ondansetron hydrochloride was subjected to forced degradation studies under various conditions of hydrolysis (acidic, basic, and neutral), oxidation, photolysis, and thermal as prescribed by International Conference on Harmonisation guideline Q1A (R2). A simple, selective, precise, and accurate high-performance liquid chromatography method was developed on a Waters Xterra C18 (150 × 4.6 mm id, 3.5 μm) column using 10 mM ammonium formate (pH 3.0)/methanol as a mobile phase in gradient elution mode at a flow rate of 0.6 mL/min. The method was extended to liquid chromatography quadrupole time-of-flight tandem mass spectrometry for identification and structural characterization of stress degradation products of ondansetron. The drug showed significant degradation in base hydrolytic and photolytic stress conditions in the liquid state, while it was found to be stable in neutral, acidic, thermal, and oxidative stress conditions. A total of five degradation products were characterized and most probable mechanisms for the formation of degradation products have been proposed on the basis of a comparison of the fragmentation of the [M + H](+) ions of the drug and its degradation products. Finally, the developed method was validated in terms of specificity, linearity, accuracy, precision, and robustness as per International Conference on Harmonisation guideline Q2 (R1). © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Application of ultra-performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry in identification of three isoflavone glycosides and their corresponding metabolites.

    Science.gov (United States)

    Xu, Xiafen; Li, Xinhui; Liang, Xianrui

    2018-02-15

    Metabolites of isoflavones have attracted much attention in recent years due to their potential bioactivities. However, the complex constituents of the metabolic system and the low level of metabolites make them difficult to analyze. A mass spectrometry (MS) method was applied in our identification of metabolites and study of their fragmentation pathways due to the advantages of rapidity, sensitivity, and low level of sample consumption. Three isoflavone glycosides and their metabolites were identified using ultra-performance liquid chromatography coupled with quadrupole time-of-flight tandem mass spectrometry (UPLC/QTOF-MS). These metabolites were obtained by anaerobically incubating three isoflavone glycosides with human intestinal flora. The characteristic fragments of isoflavone glycosides and their metabolites were used for the identification work. Two metabolites from ononin, three metabolites from irilone-4'-O-β-D-glucoside, and five metabolites from sissotrin were identified respectively by the retention time (RT), accurate mass, and mass spectral fragmentation patterns. The losses of the glucosyl group, CO from the [M+H] + ion were observed for all the three isoflavone glycosides. The characteristic retro-Diels-Alder (RDA) fragmentation patterns were used to differentiate the compounds. The metabolic pathways of the three isoflavone glycosides were proposed according to the identified chemical structures of the metabolites. A selective, sensitive and rapid method was established for detecting and identifying three isoflavone glycosides and their metabolites using UPLC/QTOF-MS. The established method can be used for further rapid structural identification studies of metabolites and natural products. Furthermore, the proposed metabolic pathways will be helpful for understanding the in vivo metabolic process of isoflavone. Copyright © 2017 John Wiley & Sons, Ltd.

  7. On-line immunoaffinity column-liquid chromatography-tandem mass spectrometry method for trace analysis of diuron in wastewater treatment plant effluent sample.

    Science.gov (United States)

    Zhang, Xiuli; Martens, Dieter; Krämer, Petra M; Kettrup, Antonius A; Liang, Xinmiao

    2006-11-10

    An on-line immunoaffinity column with liquid chromatography/tandem mass spectrometry (IAC-LC-MS/MS) method for the determination of diuron in water matrices was described. This method used a sol-gel immunoaffinity column (20 mm x 4 mm I.D.) for on-line sample cleanup and enrichment, a monolithic analytical column (100 mm x 4.6 mm I.D.) for separation, and a triple quadrupole mass spectrometer for quantitation. The major challenges for the on-line set-up were discussed. The optimized on-line protocol was emphasized by the fact that low limit of quantitation (LOQ) of 1.0 ng/L was achieved with only 2.5-mL sample. In addition, a satisfactory accuracy ( approximately 90% of recovery) and precision (effect, the on-line IAC-LC-MS/MS analysis method can reliably determine diuron in wastewater treatment plant effluent sample.

  8. Collision-induced dissociation pathways of H1-antihistamines by electrospray ionization quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Do, Jung-Ah; Noh, Eunyoung; Yoon, Soon-Byung; Lee, Ji Hyun; Park, Sung-Kwan; Mandava, Suresh; Baek, Sun Young; Lee, Jongkook

    2017-06-01

    Over the past decades, mass spectrometry technologies have been developed to obtain mass accuracies of one ppm or less. Of the newly developed technologies, quadrupole time-of-flight mass spectrometry (Q-TOF-MS) has emerged as being well suited to routine and high-throughput analyses of pharmaceuticals. Dietary supplements and functional foods have frequently been found to be contaminated with pharmaceuticals. In our continuous efforts to develop methodologies to protect public health against adulterated dietary supplements, we have constructed a mass spectral database for 21 H 1 -antihistamines encountered as adulterants by using liquid chromatography-electrospray ionization (LC-ESI)/Q-TOF-MS, and have proposed their possible collision-induced dissociation pathways. This database will be very useful for the rapid and accurate detection of H 1 -antihistamines (known) and their analogues (unknown) illegally added to dietary supplements as well as in other sample matrices.

  9. A multi-residue method for 17 anticoccidial drugs and ractopamine in animal tissues by liquid chromatography-tandem mass spectrometry and time-of-flight mass spectrometry.

    Science.gov (United States)

    Matus, Johanna L; Boison, Joe O

    2016-05-01

    A new and sensitive multi-residue liquid chromatography-tandem mass spectrometry (LC-MS/MS) and liquid chromatography-quadrupole time-of-flight-mass spectrometry (LC-QToF-MS) method was developed and validated for the determination and confirmation of residues of 17 anticoccidials, plus free ractopamine in poultry muscle and liver, and bovine muscle, liver, and kidney tissues. The 17 anticoccidials are lasalocid, halofuginone, narasin, monensin, semduramicin, ethopabate, robenidine, buquinolate, toltrazuril as its sulfone metabolite, maduramicin, salinomycin, diclazuril, amprolium, decoquinate, dinitolmide, clopidol, and the nicarbazin metabolite DNC (N,N1-bis(4-nitrophenyl)urea). The analytes were extracted and cleaned up within a 3-hour period by simply extracting the analytes into a solvent mixture with salts followed by centrifugation, dilution, and filtration. The validated method was used in a pilot study for the analysis of 173 samples that included quail liver, bovine kidney, liver, muscle, and horse muscle. The predominant residues found in this study were monensin, ractopamine, and lasalocid. The results of this pilot study showed that this new method is applicable to real samples, and is fit for use in a regulatory testing programme. © 2016 Her Majesty the Queen in Right of Canada. Drug Testing and Analysis. © 2016 John Wiley & Sons, Ltd. © 2016 Her Majesty the Queen in Right of Canada. Drug Testing and Analysis. © 2016 John Wiley & Sons, Ltd.

  10. Rapid Screening of Bovine Milk Oligosaccharides in a Whey Permeate Product and Domestic Animal Milks by Accurate Mass Database and Tandem Mass Spectral Library

    Science.gov (United States)

    Lee, Hyeyoung; Cuthbertson, Daniel J.; Otter, Don E.; Barile, Daniela

    2018-01-01

    A bovine milk oligosaccharide (BMO) library, prepared from cow colostrum, with 34 structures was generated and used to rapidly screen oligosaccharides in domestic animal milks and a whey permeate powder. The novel library was entered into a custom Personal Compound Database and Library (PCDL) and included accurate mass, retention time, and tandem mass spectra. Oligosaccharides in minute-sized samples were separated using nanoliquid chromatography (nanoLC) coupled to a high resolution and sensitive quadrupole-Time of Flight (Q-ToF) MS system. Using the PCDL, 18 oligosaccharides were found in a BMO-enriched product obtained from whey permeate processing. The usefulness of the analytical system and BMO library was further validated using milks from domestic sheep and buffaloes. Through BMO PCDL searching, 15 and 13 oligosaccharides in the BMO library were assigned in sheep and buffalo milks, respectively, thus demonstrating significant overlap between oligosaccharides in bovine (cow and buffalo) and ovine (sheep) milks. This method was shown to be an efficient, reliable, and rapid tool to identify oligosaccharide structures using automated spectral matching. PMID:27428379

  11. The analysis of diagnostic markers of genetic disorders in human blood and urine using tandem mass spectrometry with liquid secondary ion mass spectrometry

    Science.gov (United States)

    Millington, David S.; Kodo, Naoki; Terada, Naoto; Roe, Diane; Chace, Donald H.

    1991-12-01

    A method has been developed for the rapid diagnosis of metabolic diseases based on the analysis of characteristic metabolites in body fluids by fast atom bombardment or liquid secondary ion tandem mass spectrometry (FAB-MS--MS or LSIMS--MS). Acylcarnitine profiles were obtained from 100 [mu]l urine. 200 [mu]l plasma or 25 [mu]l whole blood spotted onto filter paper by simple solvent extraction, esterification and analysis using a precursor ion scan function on a triple quadrupole mass spectrometer. Specificity and sensitivity were improved by adding a small percentage of sodium octyl sulfate to the liquid matrix, which forms ion pairs with acylcarnitine esters. Acylglycines in urine were specifically detected as a group using a different precursor ion scan function. By forming methyl esters, metabolic profiles of both acylcarnitines and acylglycines were achieved in the same sample loading by application of alternating scan functions. Quantitative analysis of selected metabolites was achieved by use of stable isotope-labeled internal standards. Amino acid profiles were obtained from 100 [mu]l plasma and 25 [mu]l whole blood spots using butyl esters and a neutral loss scan function. The quantitative analysis of phenylalanine and tyrosine was achieved in these samples using stable isotope dilution. This capability will facilitate the diagnosis of phenylketonuria and other amino acidemias. These new methods have the requirements of speed, accuracy and capability for automation necessary for large-scale neonatal screening of inborn errors of matabolism.

  12. Authentication of Fish Products by Large-Scale Comparison of Tandem Mass Spectra

    DEFF Research Database (Denmark)

    Wulff, Tune; Nielsen, Michael Engelbrecht; Deelder, André M.

    2013-01-01

    Authentication of food is a major concern worldwide to ensure that food products are correctly labeled in terms of which animals are actually processed for consumption. Normally authentication is based on species recognition by comparison of selected sequences of DNA or protein. We here present...... a new robust, proteome-wide tandem mass spectrometry method for species recognition and food product authentication. The method does not use or require any genome sequences or selection of tandem mass spectra but uses all acquired data. The experimental steps were performed in a simple, standardized...... workflow including protein extraction, digestion, and data analysis. First, a set of reference spectral libraries was generated using unprocessed muscle tissue from 22 different fish species. Query tandem mass spectrometry data sets from “unknown” fresh muscle tissue samples were then searched against...

  13. Plasma Desorption Mass Spectrometry using TANDEM accelerator in National Industrial Research Inst. of Nagoya

    Energy Technology Data Exchange (ETDEWEB)

    Mizota, Takeshi; Nakao, Setsuo; Niwa, Hiroaki; Saito, Kazuo [Particle Beam Sceince Laboratory, Multi-Function Material Science Department, National Industrial Research Inst. of Nagoya, Nagoya (Japan)

    2001-02-01

    Plasma Desorption Mass Spectrometry (PDMS) analysis was studied using TANDEM accelerator. The heavy ions of MeV range emit the secondary ions of atoms, molecules, polymers and clusters from the irradiated samples without destruction. The analysis system of PDMS designed and set-up using a mass spectrometer of Time of Flight and the TANDEM accelerator. The system performance was tested for C-60 fullerene on the surface of the samples using 11.2 MeV {sup 28}Si beams produced by the TANDEM accelerator of 1.7MV. The result shows that the hydrogen and hydrocarbons can be analyzed in the range of 1amu unit. The resolution (M/{delta}M) of the Mass Spectrometry system is confirmed to be about 1000 from the separation of the 720 and 721amu peaks, which is attributed to the C-60 fullerene including {sup 13}C atoms. (H. Katsuta)

  14. Modified quadrupole mass analyzer RGA-100 for beam plasma research in forevacuum pressure range

    Energy Technology Data Exchange (ETDEWEB)

    Zolotukhin, D. B.; Tyunkov, A. V. [Tomsk State University of Control Systems and Radioelectronics, 40 Lenin Ave., Tomsk 634050 (Russian Federation); Yushkov, Yu. G., E-mail: yuyushkov@gmail.com [Tomsk State University of Control Systems and Radioelectronics, 40 Lenin Ave., Tomsk 634050 (Russian Federation); Tomsk Polytechnic University, 30 Lenin Ave., Tomsk 634050 (Russian Federation); Oks, E. M. [Tomsk State University of Control Systems and Radioelectronics, 40 Lenin Ave., Tomsk 634050 (Russian Federation); Institute of High Current Electronics SB RAS, 2/3, Akademichesky Ave., Tomsk 634055 (Russian Federation)

    2015-12-15

    The industrial quadrupole RGA-100 residual gas analyzer was modified for the research of electron beam-generated plasma at forevacuum pressure range. The standard ionizer of the RGA-100 was replaced by three electrode extracting unit. We made the optimization of operation parameters in order to provide the maximum values of measured currents of any ion species. The modified analyzer was successfully tested with beam plasma of argon, nitrogen, oxygen, and hydrocarbons.

  15. Orthogonal Injection Ion Funnel Interface Providing Enhanced Performance for Selected Reaction Monitoring-Triple Quadrupole Mass Spectrometry.

    Science.gov (United States)

    Chen, Tsung-Chi; Fillmore, Thomas L; Prost, Spencer A; Moore, Ronald J; Ibrahim, Yehia M; Smith, Richard D

    2015-07-21

    The electrodynamic ion funnel facilitates efficient focusing and transfer of charged particles in the higher-pressure regions (e.g., ion source interfaces) of mass spectrometers, thus providing increased sensitivity. An "off-axis" ion funnel design has been developed to reduce the source contamination and interferences from, e.g. ESI droplet residue and other poorly focused neutral or charged particles with very high mass-to-charge ratios. In this study, a dual ion funnel interface consisting of an orthogonal higher pressure electrodynamic ion funnel (HPIF) and an ion funnel trap combined with a triple quadrupole mass spectrometer was developed and characterized. An orthogonal ion injection inlet and a repeller plate electrode was used to direct ions to an ion funnel HPIF at a pressure of 9-10 Torr. Key factors for the HPIF performance characterized included the effects of RF amplitude, the DC gradient, and operating pressure. Compared to the triple quadrupole standard interface more than 4-fold improvement in the limit of detection for the direct quantitative MS analysis of low abundance peptides was observed. The sensitivity enhancement in liquid chromatography selected reaction monitoring (LC-SRM) analyses of low-abundance peptides spiked into a highly complex mixture was also compared with that obtained using both a commercial S-lens interface and an in-line dual-ion funnel interface.

  16. Large pore dermal microdialysis and liquid chromatography-tandem mass spectroscopy shotgun proteomic analysis: a feasibility study.

    Science.gov (United States)

    Petersen, Lars J; Sørensen, Mette A; Codrea, Marius C; Zacho, Helle D; Bendixen, Emøke

    2013-11-01

    The purpose of the present pilot study was to investigate the feasibility of combining large pore dermal microdialysis with shotgun proteomic analysis in human skin. Dialysate was recovered from human skin by 2000 kDa microdialysis membranes from one subject at three different phases of the study; trauma due to implantation of the dialysis device, a post implantation steady-state period, and after induction of vasodilatation and plasma extravasation. For shotgun proteomics, the proteins were extracted and digested with trypsin. Peptides were separated by capillary and nanoflow HPLC systems, followed by tandem mass spectrometry (MS/MS) on a Quadrupole-TOF hybrid instrument. The MS/MS spectra were merged and mapped to a human target protein database to achieve peptide identification and protein inference. Results showed variation in protein amounts and profiles for each of the different sampling phases. The total protein concentration was 1.7, 0.6, and 1.3 mg/mL during the three phases, respectively. A total of 158 different proteins were identified. Immunoglobulins and the major classes of plasma proteins, including proteases, coagulation factors, apolipoproteins, albumins, and complement factors, make up the major load of proteins in all three test conditions. Shotgun proteomics allowed the identification of more than 150 proteins in microdialysis samples from human skin. This highlights the opportunities of LC-MS/MS to study the complex molecular interactions in the skin. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Multi-residue determination of plant growth regulators in apples and tomatoes by liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Xue, Jiaying; Wang, Suli; You, Xiangwei; Dong, Jiannan; Han, Lijun; Liu, Fengmao

    2011-11-15

    A sensitive and rapid multi-residue analytical method for plant growth regulators (PGRs) (i.e., chlormequat, mepiquat, paclobutrazol, uniconazole, ethephon and flumetralin) in apples and tomatoes was developed using high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS). A homogenised sample was extracted with a mixture of methanol/water (90:10, v/v) and adjusted to pH <3 with formic acid. Primary secondary amine (PSA) adsorbent was used to clean up the sample. The determination was performed using electrospray ionisation (ESI) and a triple quadrupole (QqQ) analyser. Under the optimised method, the results showed that, except for ethephon, the recoveries were 81.8-98.1% in apples and tomatoes at the spiked concentrations of 0.005 to 2 mg/kg, with relative standard deviations (RSDs) of less than 11.7%. The limits of quantification (LOQs) were lower than their maximum residue limits (MRLs). The procedure was concluded as a practical method to determine the PGR residues in fruit and vegetables and is also suitable for the simultaneous analysis of the amounts of samples for routine monitoring. The analytical method described herein demonstrates a strong potential for its application in the field of PGR multi-residue analysis to help assure food safety. Copyright © 2011 John Wiley & Sons, Ltd.

  18. Pesticide residue determination in surface waters by stir bar sorptive extraction and liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Giordano, A; Fernández-Franzón, M; Ruiz, M J; Font, G; Picó, Y

    2009-03-01

    In this stir bar sorptive extraction (SBSE) method, 16 pesticides were extracted from surface water samples by sorption onto 1 mm polydimethylsiloxane layer coated on a 10-mm-length stir bar magnet. After liquid desorption of the analytes with 1 ml of methanol, the detection was performed on a liquid chromatography-tandem mass spectrometry with a triple quadrupole (QqQ) analyzer using selected reaction monitoring mode via electrospray ionization. Parameters affecting SBSE operation, including sample volume, salt addition, extraction time, stirring rate, and desorption conditions, have been evaluated. The optimized SBSE method required two 50 ml aliquots of surface water samples, one aliquot was added of 30% NaCl and stirred at 900 rpm during 1 h for testing five pesticides with log K(o/w) 3. The method was validated in spiked surface water samples at limits of quantifications (LOQs) and ten times the LOQs showing recoveries Albufera Lake and surrounding channels, showing that SBSE is a powerful tool for routine control analysis of pesticide residues in surface water.

  19. Tandem mass spectrometric analysis of novel diquaternary ammonium gemini surfactants and their bromide adducts in electrospray-positive ion mode ionization.

    Science.gov (United States)

    Buse, Joshua; Badea, Ildiko; Verrall, Ronald E; El-Aneed, Anas

    2011-10-01

    Gemini surfactants are cationic lipids which are utilized for both in vitro and in vivo gene delivery. Structurally, they are comprised of two hydrophobic tail regions with polar head termini that are attached to one another through a spacer region. Structural elucidation and characterization of 29 novel diquaternary ammonium gemini surfactant molecules were achieved using a quadrupole time-of-flight mass spectrometer (QqToF-MS) and a quadrupole-hexapole-quadrupole mass spectrometer (QhQ-MS). The tested compounds were categorized into four distinct structural families based upon the composition of the spacer region. Single stage (MS), tandem stage (MS/MS) and quasimulti-stage (quasi MS(3)) mass spectrometric analysis allowed for confirmation of each gemini surfactant's molecular composition and structure through the identification of common and unique product ions. Identification of similarities in the gemini surfactants' fragmentation behaviour resulted in the production of a universal fragmentation pathway that can assist in the future MS/MS analysis of novel quaternary ammonium gemini surfactants, with unique product ions being indicative of specific structural elements. Furthermore, evidence for the association of agemini surfactant with bromine counter ion was confirmed during MS analysis of tested gemini surfactants regardless of their chemical composition; previously, evidence for bromine and gemini surfactant association was only observed with compounds bearing short alkyl spacer regions. MS/MS analysis of the bromine adducts was also confirmatory to the molecular structure.Understanding the ionization and fragmentation behaviour of gemini surfactants, including bromine adducts, will allow for future qualitative and quantitative identification of these novel drug delivery agents within biological samples. Copyright © 2011 John Wiley & Sons, Ltd.

  20. Determination of vanillin, ethyl vanillin, and coumarin in infant formula by liquid chromatography-quadrupole linear ion trap mass spectrometry.

    Science.gov (United States)

    Shen, Yan; Han, Chao; Liu, Bin; Lin, Zhengfeng; Zhou, Xiujin; Wang, Chengjun; Zhu, Zhenou

    2014-02-01

    A simple, precise, accurate, and validated liquid chromatography-quadrupole linear ion trap mass spectrometry method was developed for the determination of vanillin, ethyl vanillin, and coumarin in infant formula samples. Following ultrasonic extraction with methanol/water (1:1, vol/vol), and clean-up on an HLB solid-phase extraction cartridge (Waters Corp., Milford, MA), samples were separated on a Waters XSelect HSS T3 column (150 × 2.1-mm i.d., 5-μm film thickness; Waters Corp.), with 0.1% formic acid solution-acetonitrile as mobile phase at a flow rate of 0.25 mL/min. Quantification of the target was performed by the internal standard approach, using isotopically labeled compounds for each chemical group, to correct matrix effects. Data acquisition was carried out in multiple reaction monitoring transitions mode, monitoring 2 multiple reaction monitoring transitions to ensure an accurate identification of target compounds in the samples. Additional identification and confirmation of target compounds were performed using the enhanced product ion modus of the linear ion trap. The novel liquid chromatography-quadrupole linear ion trap mass spectrometry platform offers the best sensitivity and specificity for characterization and quantitative determination of vanillin, ethyl vanillin, and coumarin in infant formula and fulfills the quality criteria for routine laboratory application. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  1. Tandem Mass Spectrometry on a Miniaturized Laser Desorption Time-of-Flight Mass Spectrometer

    Science.gov (United States)

    Li, Xiang; Cornish, Timothy; Getty, Stephanie A.; Brinckerhoff, William B.

    2016-01-01

    Tandem mass spectrometry (MSMS) is a powerful and widely-used technique for identifying the molecular structure of organic constituents of a complex sample. Application of MSMS to the study of unknown planetary samples on a remote space mission would contribute to our understanding of the origin, evolution, and distribution of extraterrestrial organics in our solar system. Here we report on the realization of MSMS on a miniaturized laser desorption time-of-flight mass spectrometer (LD-TOF-MS), which is one of the most promising instrument types for future planetary missions. This achievement relies on two critical components: a curved-field reflectron and a pulsed-pin ion gate. These enable use of the complementary post-source decay (PSD) and laser-assisted collision induced dissociation (L-CID) MSMS methods on diverse measurement targets with only modest investment in instrument resources such as volume and weight. MSMS spectra of selected molecular targets in various organic standards exhibit excellent agreement when compared with results from a commercial, laboratory-scale TOF instrument, demonstrating the potential of this powerful technique in space and planetary environments.

  2. Analysis of glyphosate and aminomethylphosphonic acid in leaves from Coffea arabica using high performance liquid chromatography with quadrupole mass spectrometry detection.

    Science.gov (United States)

    Schrübbers, Lars C; Masís-Mora, Mario; Rojas, Elizabeth Carazo; Valverde, Bernal E; Christensen, Jan H; Cedergreen, Nina

    2016-01-01

    Glyphosate is a commonly applied herbicide in coffee plantations. Because of its non-selective mode of action it can damage the crop exposed through spray drift. Therefore, it is of interest to study glyphosate fate in coffee plants. The aim of this study was to develop an analytical method for accurate and precise quantification of glyphosate and its main metabolite aminomethylphosphonic acid (AMPA) at trace levels in coffee leaves using liquid chromatography with single-quadrupole mass spectrometry detection. The method is based on a two-step solid phase extraction (SPE) with an intermediate derivatization reaction using 9-fluorenylmethylchloroformate (FMOC). An isotope dilution method was used to account for matrix effects and to enhance the confidence in analyte identification. The limit of quantification (LOQ) for glyphosate and AMPA in coffee leaves was 41 and 111 μg kg(-1) dry weight, respectively. For the method optimization a design of experiments (DOE) approach was used. The sample clean-up procedure can be simplified for the analysis of less challenging matrices, for laboratories having a tandem mass spectrometry detector and for cases in which quantification limits above 0.1 mg kg(-1) are acceptable, which is often the case for glyphosate. The method is robust, possesses high identification confidence, while being suitable for most commercial and academic laboratories. All leaf samples from five coffee fields analyzed (n=21) contained glyphosate, while AMPA was absent. The simplified clean-up procedure was successfully validated for coffee leaves, rice, black beans and river water. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Simultaneous identification and quantification of tetrodotoxin in fresh pufferfish and pufferfish-based products using immunoaffinity columns and liquid chromatography/quadrupole-linear ion trap mass spectrometry

    Science.gov (United States)

    Guo, Mengmeng; Wu, Haiyan; Jiang, Tao; Tan, Zhijun; Zhao, Chunxia; Zheng, Guanchao; Li, Zhaoxin; Zhai, Yuxiu

    2017-07-01

    In this study, we established a comprehensive method for simultaneous identification and quantification of tetrodotoxin (TTX) in fresh pufferfish tissues and pufferfish-based products using liquid chromatography/quadrupole-linear ion trap mass spectrometry (LC-QqLIT-MS). TTX was extracted by 1% acetic acid-methanol, and most of the lipids were then removed by freezing lipid precipitation, followed by purification and concentration using immunoaffinity columns (IACs). Matrix effects were substantially reduced due to the high specificity of the IACs, and thus, background interference was avoided. Quantitation analysis was therefore performed using an external calibration curve with standards prepared in mobile phase. The method was evaluated by fortifying samples at 1, 10, and 100 ng/g, respectively, and the recoveries ranged from 75.8%-107%, with a relative standard deviation of less than 15%. The TTX calibration curves were linear over the range of 1-1 000 μg/L, with a detection limit of 0.3 ng/g and a quantification limit of 1 ng/g. Using this method, samples can be further analyzed using an information-dependent acquisition (IDA) experiment, in the positive mode, from a single liquid chromatography-tandem mass spectrometry injection, which can provide an extra level of confirmation by matching the full product ion spectra acquired for a standard sample with those from an enhanced product ion (EPI) library. The scheduled multiple reaction monitoring method enabled TTX to be screened for, and TTX was positively identified using the IDA and EPI spectra. This method was successfully applied to analyze a total of 206 samples of fresh pufferfish tissues and pufferfish-based products. The results from this study show that the proposed method can be used to quantify and identify TTX in a single run with excellent sensitivity and reproducibility, and is suitable for the analysis of complex matrix pufferfish samples.

  4. Comprehensive multidimensional gas chromatography coupled to low resolution quadrupole mass spectrometry for the analysis of PCDDs, PCDFs and PCBs

    Energy Technology Data Exchange (ETDEWEB)

    Costa, J.P. [Universitat de Barcelona (Spain). Facultat de Quimica, Dept. de Quimica Analitica; Korytar, P.; Boer, J. de [Netherlands Institutes for Fisheries Research, Ijmuiden (Netherlands); Leonards, P. [Instituto Quimico de Sarria, Barcelona (Spain)

    2004-09-15

    Because of the high persistency and extreme toxicity of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) and so-called dioxin-like polychlorinated biphenyls (PCBs), their trace level determination is a topic of much interest. The typical concentrations of this compounds, sub-ng/kg, makes that they have to be clearly separated from other, less toxic, congeners present in the samples and from the matrix and the use of sensitive techniques is required for the quantification. The analyses of the compounds are usually done by high resolution gas chromatography coupled to high resolution mass spectrometry (HRGC-HRMS). Recently, alternative novel techniques have been developed which are improving the chromatographic separation, e.g. comprehensive multidimensional gas chromatography (GC x GC), for the analysis of the compounds. The aim of this work is to evaluate GC x GC coupled to a low resolution quadrupole mass spectrometer for the quantification of PCDDs, PCDFs and dioxin like PCBs.

  5. Silver/oxygen depth profile in coins by using laser ablation, mass quadrupole spectrometer and X-rays fluorescence

    International Nuclear Information System (INIS)

    Cutroneo, M.; Torrisi, L.; Caridi, F.; Sayed, R.; Gentile, C.; Mondio, G.; Serafino, T.; Castrizio, E.D.

    2013-01-01

    Silver coins belonging to different historical periods were investigated to determine the Ag/O atomic ratio depth profiles. Laser ablation has been employed to remove, in high vacuum, the first superficial layers of the coins. Mass quadrupole spectrometry has been used to detect the Ag and the O atomic elements vaporized from the coin surface. The depth profile allowed to determine the thickness of the oxidation layer indicating that, in general, it is high in old coins. A complementary technique, using scanning electron microscope and the associated XRF microprobe, have been devoted to confirm the measurements of Ag/O atomic ratio measured with the laser-coupled mass spectrometry. The oxidation layer thicknesses range between about 25 and 250 microns.

  6. [Structure identification of contaminants in a beverage product by liquid chromatography coupled with quadrupole time-of-flight mass spectrometry].

    Science.gov (United States)

    Miyamoto, Yasuhisa; Washida, Kazuto; Uyama, Atsuo; Mochizuki, Naoki

    2014-01-01

    The contaminants in a beverage product that had been reported to have a strange taste were identified. By comparative analysis with the normal product using liquid chromatography coupled with quadrupole time-of-flight mass spectrometry (LC-QTOF-MS), six unknown compounds were detected in the total ion current chromatograms of the product in question. Detailed analysis of the mass spectra and product ion spectra of these compounds strongly suggested that the compounds were capric acid diethanolamide, lauric acid diethanolamide, myristic acid diethanolamide, lauryl dimethylaminoacetic acid, lauryl sulfate, and lauric acid, all of which are surfactants commonly used as ingredients of household detergents and shampoos. We searched commercially available detergent products to check for the presence of these six surfactants, and identified products that might have been intentionally or unintentionally mixed into the beverage product after opening.

  7. Quantification and validation of ertapenem using a liquid chromatography-tandem mass spectrometry method

    NARCIS (Netherlands)

    van Rijn, S.P.; Wessels, A.M.A.; Greijdanus, B.; Touw, D.J.; Alffenaar, J.W.C.

    Ertapenem, a carbapenem, relies on time-dependent killing. Therapeutic drug monitoring (TDM) should be considered, when ertapenem is used in specific populations, to achieve optimal bactericidal activity and optimize drug-dosing regimens. No validated liquid chromatography-tandem mass spectrometry

  8. Determination of Bedaquiline in Human Serum Using Liquid Chromatography-Tandem Mass Spectrometry

    NARCIS (Netherlands)

    Alffenaar, Jan-Willem C.; Bolhuis, Mathieu; van Hateren, Kai; Sturkenboom, Marieke; Akkerman, Onno; de Lange, Wiel; Greijdanus, Ben; van der Werf, Tjip; Touw, Daan

    Bedaquiline, a diarylquinoline for the treatment of multidrug-resistant tuberculosis (TB), relies on exposure-dependent killing. As data on drug exposure in specific populations are scarce, pharmacokinetic studies may be of interest. No simple and robust validated liquid chromatography-tandem mass

  9. Liquid chromatographic-tandem mass spectrometric determination of selected sulphonamides in milk

    NARCIS (Netherlands)

    Rhijn, van J.A.; Lasaroms, J.J.P.; Berendsen, B.J.A.; Brinkman, U.A.Th.

    2002-01-01

    Liquid chromatography–tandem mass spectrometry is used for the quantitative analysis of selected sulphonamides in milk. Ultrafiltration is the only sample pre-treatment technique which is required. Consequently, sample throughput is much higher than with conventional procedures, and analyte

  10. Cytokinin profiling in plant tissues using ultra-performance liquid chromatography–electrospray tandem mass spectrometry

    Czech Academy of Sciences Publication Activity Database

    Novák, Ondřej; Hauserová, Eva; Amakorová, Petra; Doležal, Karel; Strnad, Miroslav

    2008-01-01

    Roč. 69, č. 11 (2008), s. 2214-2224 ISSN 0031-9422 R&D Projects: GA AV ČR KAN200380801 Institutional research plan: CEZ:AV0Z50380511 Keywords : Ultra-performance liquid chromatography (UPLC) * Tandem mass spectrometry (MS/MS) * Microextraction Subject RIV: EC - Immunology Impact factor: 2.946, year: 2008

  11. Rapid analysis of ß-agonists in urine by thermospray tandem mass spectrometry

    NARCIS (Netherlands)

    Rhijn, van J.A.; O'Keeffe, M.; Heskamp, H.H.; Collins, S.

    1995-01-01

    A method is described for the analysis of -agonists in urine of cattle. The method uses solid-phase extraction (SPE), followed by analysis of the resulting extract by flow injection thermospray tandem mass spectrometry (TSP-MS-MS). Sample preparation is performed using a mixed-bed SPE procedure

  12. Confirmatory analysis of acetylgestagens in plasma using liquid chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Mortensen, Sarah Kelly; Pedersen, Mikael

    2007-01-01

    -assisted liquid-liquid extraction (LLE) on Extrelut NT columns followed by C18 solid-phase extraction (SPE). Analytes were analysed using liquid chromatography-tandem mass spectrometry (I-C-MS/MS), and quantification was performed using matrix-matched calibration standards in combination with deuterated internal...

  13. Tandem mass spectrometry newborn screening for inborn errors of intermediary metabolism: abnormal profile interpretation.

    Science.gov (United States)

    Fernández-Lainez, C; Aguilar-Lemus, J J; Vela-Amieva, M; Ibarra-González, I

    2012-01-01

    Expanded newborn screening for inherited metabolic disorders using tandem mass spectrometry was introduced in 1990's and is widely used around the world. In contrast to conventional screening methods, tandem mass spectrometry does not measure single analytes but identifies and quantifies metabolite profiles; one single blood spot analyzed provides information of about 60 metabolites including amino acids, acylcarnitines and related ratios that enable the diagnosis of approximately 50 different diseases. However, the interpretation of these profiles can become quite complex. The aim of this work is to present in an easy and practical manner a comprehensive compilation of information needed for tandem mass neonatal screening profile interpretation, and basic actions for immediate follow up of abnormal results, including the tests that are required for confirmatory purposes. Other conditions not attributable to metabolic disorders which can lead to an abnormal profile of these markers are also described as well as a series of general recommendations which would be useful for health professionals who are beginning newborn screening for inborn errors of intermediary metabolism using tandem mass spectrometry.

  14. Direct sampling tandem mass spectrometry (MS/MS) and multiway calibration for isomer quantitation

    NARCIS (Netherlands)

    Zampronio, Cleidiane G.; Gurden, Stephen P.; Moraes, Luis Alberto B.; Eberlin, Marcos N.; Smilde, Age K.; Poppi, Ronei J.

    2002-01-01

    Direct sampling tandem mass spectrometry (MS/MS) was used for the quantitation of mixtures of the isomers 2-, 3- and 4-ethyl pyridine. The similarity between the analytes and the second-order nature of MS/MS data require the use of multivariate calibration techniques capable of handling multiway

  15. Comparison of negative and positive ion electrospray tandem mass spectrometry for the liquid chromatography tandem mass spectrometry analysis of oxidized deoxynucleosides.

    Science.gov (United States)

    Hua, Y; Wainhaus, S B; Yang, Y; Shen, L; Xiong, Y; Xu, X; Zhang, F; Bolton, J L; van Breemen, R B

    2001-01-01

    Oxidized deoxynucleosides are widely used as biomarkers for DNA oxidation and oxidative stress assessment. Although gas chromatography mass spectrometry is widely used for the measurement of multiple DNA lesions, this approach requires complex sample preparation contributing to possible artifactual oxidation. To address these issues, a high performance liquid chromatography (HPLC)-tandem mass spectrometric (LC-MS/MS) method was developed to measure 8-hydroxy-2'-deoxyguanosine (8-OH-dG), 8-hydroxy-2'-deoxyadenosine (8-OH-dA), 2-hydroxy-2'-deoxyadenosine (2-OH-dA), thymidine glycol (TG), and 5-hydroxy-methyl-2'-deoxyuridine (HMDU) in DNA samples with fast sample preparation. In order to selectively monitor the product ions of these precursors with optimum sensitivity for use during quantitative LC-MS/MS analysis, unique and abundant fragment ions had to be identified during MS/MS with collision-induced dissociation (CID). Positive and negative ion electrospray tandem mass spectra with CID were compared for the analysis of these five oxidized deoxynucleosides. The most abundant fragment ions were usually formed by cleavage of the glycosidic bond in both positive and negative ion modes. However, in the negative ion electrospray tandem mass spectra of 8-OH-dG, 2-OH-dA, and 8-OH-dA, cleavage of two bonds within the sugar ring produced abundant S1 type ions with loss of a neutral molecule weighing 90 u, [M - H - 90]-. The signal-to-noise ratio was similar for negative and positive ion electrospray MS/MS except in the case of thymidine glycol where the signal-to-noise was 100 times greater in negative ionization mode. Therefore, negative ion electrospray tandem mass spectrometry with CID would be preferred to positive ion mode for the analysis of sets of oxidized deoxynucleosides that include thymidine glycol. Investigation of the fragmentation pathways indicated some new general rules for the fragmentation of negatively charged oxidized nucleosides. When purine

  16. Quantitative analysis of phytosterols in edible oils using APCI liquid chromatography-tandem mass spectrometry

    OpenAIRE

    Mo, Shunyan; Dong, Linlin; Hurst, W. Jeffrey; van Breemen, Richard B.

    2013-01-01

    Previous methods for the quantitative analysis of phytosterols have usually used GC-MS and require elaborate sample preparation including chemical derivatization. Other common methods such as HPLC with absorbance detection do not provide information regarding the identity of the analytes. To address the need for an assay that utilizes mass selectivity while avoiding derivatization, a quantitative method based on LC-tandem mass spectrometry (LC-MS-MS) was developed and validated for the measur...

  17. Spray-inlet microwave plasma torch ionization tandem mass spectrometry for the direct detection of drug samples in liquid solutions.

    Science.gov (United States)

    Miao, Meng; Zhao, Gaosheng; Wang, Yaliang; Xu, Li; Dong, Junguo; Cheng, Ping

    2017-12-30

    Drug abuse or dependence results in a series of social problems, including crime and traffic accidents. Spray-inlet microwave plasma torch tandem mass spectrometry (MPT-MS/MS) was developed and used for the direct detection of such drugs in liquid solutions. Drug sample solutions were directly sprayed into the flame of an MPT by a sampling pump and the ions produced by Penning ionization and ion-molecule reactions were guided into a quadrupole time-of-flight (QTOF) tandem mass spectrometer for mass analysis. The MPT was operated at 40 W and 2.45 GHz in a 700 mL/min argon flow both for the inner and middle plasma. Intact quasi-molecular and molecular ions of various drugs were successfully characterized by spray-inlet MPT-MS/MS. The analysis of one sample was finished within 30 s. Furthermore, the method exhibited excellent efficiency, precision and sensitivity, and the limits of detection and limits of quantification of the samples in methanol were in the range of 5.25-60.0 and 17.5-200 ng g -1 , respectively. Excellent linearities with coefficients of determination (R 2 ) of 0.9627-0.9980 were verified in the range 0.05-50 μg g -1 . Four different beverages purchased locally were also analyzed with spray-inlet MPT-MS/MS, and caffeine was directly determined in two of the beverages. By adding six standard drug samples to sport drinks (each drug was 1 μg g -1 ) and Chinese spirit (each drug was 0.1 μg g -1 ), all the drugs except for caffeine were detected successfully. This study indicates that spay-inlet MPT-MS/MS is an effective method for direct and rapid identification of drug solutions, and it has substantial potential for fast and sensitive drug residue detection. Copyright © 2017 John Wiley & Sons, Ltd.

  18. Qualitative and Quantitative Analysis of Major Triterpenoids in Alismatis Rhizoma by High Performance Liquid Chromatography/Diode-Array Detector/Quadrupole-Time-of-Flight Mass Spectrometry and Ultra-Performance Liquid Chromatography/Triple Quadrupole Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Wanli Zhao

    2015-07-01

    Full Text Available Alismatis Rhizoma (AMR is a well-known natural medicine with a long history in Chinese medicine and has been commonly used for treating a wide range of ailments related to dysuria, edema, nephropathy, hyperlipidaemia, diabetes, inflammation as well as tumors in clinical applications. Most beneficial effects of AMR are attributed to the presence of protostane terpenoids, the major active ingredients of Alismatis Rhizoma (AMR. In this study, a systematic high performance liquid chromatography/diode-array detector/quadrupole-time-of-flight mass spectrometry (HPLC-DAD-Q-TOF MS and ultra-performance liquid chromatography/triple quadrupole mass spectrometry (UPLC-QqQ MS method was developed for qualitative and quantitative analyses of the major AMR triterpenoids. First, a total of 25 triterpenoid components, including 24 known compounds and one new compound were identified by comparison with UV spectra, molecular ions and fragmentation behaviors of reference standards or the literature. Second, an efficient method was established for the rapid simultaneous determination of 14 representative triterpenoids by UPLC-QqQ MS. Forty-three batches of AMR were analyzed with linearity (r, 0.9980–0.9999, intra-day precision (RSD, 1.18%–3.79%, inter-day precision (RSD, 1.53%–3.96%, stability (RSD, 1.32%–3.97%, repeatability (RSD, 2.21%–4.25%, and recovery (98.11%–103.8%. These results indicated that new approaches combining HPLC-DAD-Q-TOF MS and UPLC-QqQ MS are applicable in the qualitative and quantitative analysis of AMR.

  19. Determination of pesticide residues and related compounds in water and industrial effluent by solid-phase extraction and gas chromatography coupled to triple quadrupole mass spectrometry.

    Science.gov (United States)

    Martins, Manoel L; Donato, Filipe F; Prestes, Osmar D; Adaime, Martha B; Zanella, Renato

    2013-09-01

    Pollution of drinking water supplies from industrial waste is a result of several industrial processes and disposal practices, and the establishment of analytical methods for monitoring organic compounds related to environmental and health problems is very important. In this work, a method using solid-phase extraction (SPE) and gas chromatography coupled to triple quadrupole tandem mass spectrometry (GC-QqQ-MS/MS) was developed and validated for the simultaneous determination of pesticide residues and related compounds in drinking and surface water as well as in industrial effluent. Optimization of the method was achieved by using a central composite design approach on parameters such as the sample pH and SPE eluent composition. A single SPE consisting of the loading on a polymeric sorbent of 100 mL of sample adjusted to pH 3 and elution with methanol/methylene chloride (10:90, v/v) permitted the obtaining of acceptable recoveries in most cases. The concentration factor associated with sensitivity of the chromatographic analysis permitted the achievement of the method limit of detection values between 0.01 and 0.25 μg L(-1). Recovery assays presented mean recoveries between 70 and 120% for most of the compounds with very good precision, despite the different chemical nature of the compounds analyzed. The selectivity of the method, evaluated through the relative intensity of quantification and qualification ions obtained by GC-QqQ-MS/MS, was considered adequate. The developed method was finally applied to the determination of target analytes in real samples. River water and treated industrial effluent samples presented residues of some compounds, but no detectable residues were found in the drinking water samples evaluated.

  20. Determination of parabens in urine samples by microextraction using packed sorbent and ultra-performance liquid chromatography coupled to tandem mass spectrometry.

    Science.gov (United States)

    Cristina Jardim, Valeria; de Paula Melo, Lidervan; Soares Domingues, Diego; Costa Queiroz, Maria Eugênia

    2015-01-01

    A simple, sensitive, and selective method using ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS) was developed and validated for simultaneous determination of parabens [methyl paraben (MeP), ethyl paraben (EtP), propyl paraben (PrP), butyl paraben (BuP), and benzyl paraben (BzP)] in human urine samples. After microextraction by packed sorbent (MEPS) using a C18 phase, the parabens were separated on a Kinetex C18 column (100 mm × 2.1 mm × 1.7 μm) within 4.6 min using isocratic elution. These compounds were detected on a triple quadrupole tandem mass spectrometer using the multiple reactions monitoring (MRM) mode via an electrospray ionization source operating in the negative ionization mode. Important factors that influence MEPS performance were evaluated, such as the sample pH, draw-eject sample volume, clean-up step, and desorption conditions. The proposed MEPS/UPLC-MS/MS method presented a linear range from 0.5 ng mL(-1) (limit of quantification - LOQ) to 50 ng mL(-1), and interassay precision with coefficients of variation lower than 15%, and relative standard error values of the accuracy ranged from -8.8% to 15%. The MEPS/UPLC-MS/MS method was applied successfully to determine parabens in urine samples from 30 postpartum volunteers, enabling assessment of human exposure to these compounds. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Determination of cilnidipine, a new calcium antagonist, in human plasma using high performance liquid chromatography with tandem mass spectrometric detection.

    Science.gov (United States)

    Zhang, Xianhua; Zhai, Suodi; Zhao, Rongsheng; Ouyang, Jin; Li, Xiaoguang; Baeyens, Willy R G

    2007-09-26

    A rapid, sensitive and reliable high performance liquid chromatographic method coupled with tandem mass spectrometry (HPLC-MS/MS) has been developed and validated for the determination of cilnidipine, a relatively new calcium antagonist, in human plasma. The reversed-phase chromatographic system was interfaced with a TurboIonSpray (TIS) source. Nimodipine was employed as the internal standard (IS). Sample extracts following protein precipitation were injected into the HPLC-MS/MS system. The analyte and IS were eluted isocratically on a C18 column, with a mobile phase consisting of CH(3)OH and NH(4)Ac (96:4, v/v). The ions were detected by a triple quadrupole mass spectrometric detector in the negative mode. Quantification was performed using multiple reaction monitoring (MRM) of the transitions m/z 491.2-->122.1 and m/z 417.1-->122.1 for cilnidipine and for the IS, respectively. The analysis time for each run was 3.0 min. The calibration curve fitted well over the concentration range of 0.1-10 ngmL(-1), with the regression equation Y=(0.103+/-0.002)X+(0.014+/-0.003) (n=5), r=0.9994. The intra-day and inter-day R.S.D.% were less than 12.51% at all concentration levels within the calibration range. The recoveries were between 92.71% and 97.64%. The long-term stability and freeze-thaw stability were satisfying at each level. The present method provides a modern, rapid and robust tool for pharmacokinetic studies of cilnidipine.

  2. A dynamic programming approach to de novo peptide sequencing via tandem mass spectrometry.

    Science.gov (United States)

    Chen, T; Kao, M Y; Tepel, M; Rush, J; Church, G M

    2001-01-01

    Tandem mass spectrometry fragments a large number of molecules of the same peptide sequence into charged molecules of prefix and suffix peptide subsequences and then measures mass/charge ratios of these ions. The de novo peptide sequencing problem is to reconstruct the peptide sequence from a given tandem mass spectral data of k ions. By implicitly transforming the spectral data into an NC-spectrum graph G (V, E) where /V/ = 2k + 2, we can solve this problem in O(/V//E/) time and O(/V/2) space using dynamic programming. For an ideal noise-free spectrum with only b- and y-ions, we improve the algorithm to O(/V/ + /E/) time and O(/V/) space. Our approach can be further used to discover a modified amino acid in O(/V//E/) time. The algorithms have been implemented and tested on experimental data.

  3. Determination of thyroid hormones in placenta using isotope-dilution liquid chromatography quadrupole time-of-flight mass spectrometry

    DEFF Research Database (Denmark)

    Li, Zhong-Min; Giesert, Florian; Vogt-Weisenhorn, Daniela

    2018-01-01

    (13C6-T4, 13C6-T3, 13C6-rT3 and 13C6-T2) and recovery standard (13C12-T4) in combination with solid-liquid extraction, liquid-liquid extraction and solid phase extraction. The linearity was obtained in the range of 0.5-150 pg uL-1 with R2 values >0.99. The method detection limits (MDLs) ranged from 0......-l-thyronine (rT3), 3,3'-diiodo-l-thyronine (T2), 3,5-diiodo-l-thyronine (rT2), 3-iodo-l-thyronine (T1) and 3-iodothyronamine (T1AM), in placenta using isotope dilution liquid chromatography quadrupole time-of-flight mass spectrometry. We optimized the method using isotopically labeled quantification standards...

  4. Untargeted screening of sulfonamides and their metabolites in salmon using liquid chromatography coupled to quadrupole Orbitrap mass spectrometry.

    Science.gov (United States)

    Jia, Wei; Shi, Lin; Chu, Xiaogang

    2018-01-15

    An analytical method for the non-target screening of sulfonamides and metabolites in salmon was developed, using automated on-line extraction procedure followed by ultra-high performance liquid chromatography coupled to electrospray ionization quadrupole Orbitrap high-resolution mass spectrometry (UHPLC Q-Orbitrap), including three systematic workflows (i) fully non-targeted data acquisition with fragmentation, (ii) suspect library spectra searching followed by characteristic structural fragments filtering and (iii) confirmation of non-target analytes and structural characterization of unknown analytes based on the availability of reference standards. The estimated performance characteristics were satisfactory complying with the requirements of the guidelines specified in European Commission Decision 2002/657/EC. Four untargeted compounds were identified and confirmed from salmon samples of different origin taken from monitoring control program. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. A comparison of flavonoid glycosides by electrospray tandem mass spectrometry

    Science.gov (United States)

    March, Raymond E.; Lewars, Errol G.; Stadey, Christopher J.; Miao, Xiu-Sheng; Zhao, Xiaoming; Metcalfe, Chris D.

    2006-01-01

    A comparison is presented of product ion mass spectra of protonated and deprotonated molecules of kaempferol-3-O-glucoside, quercitin-3-O-glucoside (isoquercitrin), quercitin-3-O-galactoside (hyperoin), apigenin-7-O-glucoside, luteolin-7-O-glucoside, genistein-7-O-glucoside, naringenin-7-O-glucoside (prunin), luteolin-4'-O-glucoside, luteolin-6-C-glucoside (homoorientin, known also as isoorientin), apigenin-8-C-glucoside (vitexin), and luteolin-8-C-glucoside (orientin) together with the product ion mass spectrum of deprotonated kaempferol-7-O-glucoside. All isomeric ions were distinguishable on the basis of their product ion mass spectra. For protonated 3-O-, 7-O-, and 4'-O-glycosides at a collision energy of 46-47 eV, homolytic cleavage of the O-glycosidic bond yielded aglycon Y+ ions, whereas in deprotonated 3-O-, 7-O-, and 4'-O-glycosides, heterolytic and homolytic cleavage of the O-glycosidic bond yielded radical aglycon (Y-H)- and aglycon (Y-) ions. In each case, fragmentation of either the glycan or the aglycon or both was observed. For 6-C- and 8-C-glycosides at a collision energy of 46-47 eV, fragmentation was restricted almost exclusively to the glycan. For luteolin-6-C-glucoside, the integrity of the aglycon structure is preserved at the expense of the glycan for which some 30 fragmentations were observed. Breakdown curves were determined as a function of collision energy for protonated and deprotonated luteolin-6-C-glucoside. An attempt has been made to rationalize the product ion mass spectra derived from C-O- and C-C-luteolin glucosides in terms of computed structures that indicate significant intramolecular hydrogen bonding and rotation of the B-ring to form a coplanar luteolin structure. It is proposed that protonated and deprotonated luteolin-6-C-glucoside may afford examples of cooperative interactive bonding that plays a major role in directing fragmentation.

  6. Micro-pulverized extraction pretreatment for highly sensitive analysis of 11-nor-9-carboxy-Δ(9)-tetrahydrocannabinol in hair by liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Kuwayama, Kenji; Miyaguchi, Hajime; Yamamuro, Tadashi; Tsujikawa, Kenji; Kanamori, Tatsuyuki; Iwata, Yuko T; Inoue, Hiroyuki

    2015-11-30

    A primary metabolite of Δ(9) -tetrahydrocannabinol, 11-nor-9-carboxytetrahydrocannabinol (THC-COOH), serves as an effective indicator for cannabis intake. According to the recommendations of the Society of Hair Testing, at least 0.2 pg/mg of THC-COOH (cut-off level) must be present in a hair sample to constitute a positive result in a drug test. Typically, hair is digested with an alkaline solution and is subjected to gas chromatography/tandem mass spectrometry (GC/MS/MS) with negative ion chemical ionization (NICI). It is difficult to quantify THC-COOH at the cut-off level using liquid chromatography/tandem mass spectrometry (LC/MS/MS) without acquisition of second-generation product ions in triple quadrupole-ion trap mass spectrometers, because large amounts of matrix components in the low-mass range produced by digestion interfere with the THC-COOH peak. Using the typical pretreatment method (alkaline dissolution) and micro-pulverized extraction (MPE) with a stainless bullet, we compared the quantification of THC-COOH using GC/MS/MS and LC/MS/MS. MPE reduced the amount of matrix components in the low-mass range and enabled the quantification of THC-COOH at 0.2 pg/mg using a conventional triple quadrupole liquid chromatograph coupled to a mass spectrometer. On the other hand, the MPE pretreatment was unsuitable for GC/MS/MS, probably due to matrix components in the high-mass range. The proper combination of pretreatments and instrumental analyses was shown to be important for detecting trace amounts of THC-COOH in hair. In MPE, samples can be prepared rapidly, and LC/MS/MS is readily available, unlike GC/MS/MS with NICI. The combination of MPE and LC/MS/MS might therefore be used in the initial screening for THC-COOH in hair prior to confirmatory analysis using GC/MS/MS with NICI. Copyright © 2015 John Wiley & Sons, Ltd.

  7. Profiling the indole alkaloids in yohimbe bark with ultra-performance liquid chromatography coupled with ion mobility quadrupole time-of-flight mass spectrometry

    Science.gov (United States)

    An ultra-high performance liquid chromatography-ion mobility- quadrupole time-of-flight mass spectrometry (UHPLC-IM-QTOF-MS) method was developed for profiling the indole alkaloids in yohimbe bark. Many indole alkaloids with the yohimbine core structure, plus methylated, oxidized, and reduced speci...

  8. Validation of a qualitative screening method for pesticides in fruits and vegetables by gas chromatography quadrupole-time of flight mass spectrometry with atmospheric pressure chemical ionization

    NARCIS (Netherlands)

    Portoles, T.; Mol, J.G.J.; Sancho, J.V.; Lopez, F.J.; Hernandez, F.

    2014-01-01

    A wide-scope screening method was developed for the detection of pesticides in fruit and vegetables. The method was based on gas chromatography coupled to a hybrid quadrupole time-of-flight mass spectrometer with an atmospheric pressure chemical ionization source (GC-(APCI)QTOF MS). A non-target

  9. Metabolic profiling of Hoodia, Chamomile, Terminalia Species and evaluation of commercial preparations using Ultra-High Performance Quadrupole Time of Flight-Mass Spectrometry

    Science.gov (United States)

    Ultra-High Performance-Quadrupole Time of Flight Mass Spectrometr(UHPLC-QToF-MS)profiling has become an impattant tool for identification of marker compounds and generation of metabolic patterns that could be interrogated using chemometric modeling software. Chemometric approaches can be used to ana...

  10. On the isobaric space of 25-hydroxyvitamin D in human serum: potential for interferences in liquid chromatography/tandem mass spectrometry, systematic errors and accuracy issues.

    Science.gov (United States)

    Qi, Yulin; Geib, Timon; Schorr, Pascal; Meier, Florian; Volmer, Dietrich A

    2015-01-15

    Isobaric interferences in human serum can potentially influence the measured concentration levels of 25-hydroxyvitamin D [25(OH)D], when low resolving power liquid chromatography/tandem mass spectrometry (LC/MS/MS) instruments and non-specific MS/MS product ions are employed for analysis. In this study, we provide a detailed characterization of these interferences and a technical solution to reduce the associated systematic errors. Detailed electrospray ionization Fourier transform ion cyclotron resonance (FTICR) high-resolution mass spectrometry (HRMS) experiments were used to characterize co-extracted isobaric components of 25(OH)D from human serum. Differential ion mobility spectrometry (DMS), as a gas-phase ion filter, was implemented on a triple quadrupole mass spectrometer for separation of the isobars. HRMS revealed the presence of multiple isobaric compounds in extracts of human serum for different sample preparation methods. Several of these isobars had the potential to increase the peak areas measured for 25(OH)D on low-resolution MS instruments. A major isobaric component was identified as pentaerythritol oleate, a technical lubricant, which was probably an artifact from the analytical instrumentation. DMS was able to remove several of these isobars prior to MS/MS, when implemented on the low-resolution triple quadrupole mass spectrometer. It was shown in this proof-of-concept study that DMS-MS has the potential to significantly decrease systematic errors, and thus improve accuracy of vitamin D measurements using LC/MS/MS. Copyright © 2014 John Wiley & Sons, Ltd.

  11. Tandem Mass Spectrum Sequencing: An Alternative to Database Search Engines in Shotgun Proteomics.

    Science.gov (United States)

    Muth, Thilo; Rapp, Erdmann; Berven, Frode S; Barsnes, Harald; Vaudel, Marc

    2016-01-01

    Protein identification via database searches has become the gold standard in mass spectrometry based shotgun proteomics. However, as the quality of tandem mass spectra improves, direct mass spectrum sequencing gains interest as a database-independent alternative. In this chapter, the general principle of this so-called de novo sequencing is introduced along with pitfalls and challenges of the technique. The main tools available are presented with a focus on user friendly open source software which can be directly applied in everyday proteomic workflows.

  12. [Diagnosis of inborn errors of metabolism using tandem mass spectrometry and gas chromatography mass spectrometry].

    Science.gov (United States)

    Han, Lian-Shu; Ye, Jun; Qiu, Wen-Juan; Gao, Xiao-Lan; Wang, Yu; Jin, Jing; Gu, Xue-Fan

    2008-08-05

    To investigate the effects of tandem mass spectrometry (MS/MS) combined with gas chromatography mass spectrometry (GC-MS) in the diagnosis of inborn errors of metabolism in children. Amino acids and acylcarnitines in the dry blood filter papers were tested by MS/MS, and the organic acid profiles in urea were tested by GC-MS among 4981 children suspected to be with inborn errors of metabolism from more than 100 hospitals in China. A few pediatric patients underwent analysis of activity of enzyme and gene mutation analysis too. 319 of the 4981 children (6.4%) were diagnosed as with 24 kinds of diseases: 155 of the 319 cases (48.6%) with 8 kinds of amino acid diseases (97 with hyperphenylalaninemia, 14 with maple syrup urine disease 13 with ornithine transcarbamylase deficiency, 13 with citrullinemia type II, 10 with tyrosinemia type I, 5 with citrullinemia type I, 2 with homocystinuria, and 1 with arginasemia); 150 of the 319 cases (47.0%) were diagnosed as with 10 kinds of organic acidemias (81 with methylmalonic acidemia, 17 with propionic acidemia, 17 with multiple CoA carboxylase deficiency, 11 with glutaric acidemia type II, 8 with isovaleric acidemia, 6 with beta-keto thiolase deficiency, 5 with 3-methylcrotonyl-CoA carboxylase deficiency, and 3 with 3-hydroxy-3-methylglutaryl-CoA lyase deficiency); 14 cases (4.4%) were diagnosed as with 6 kinds of fatty acid disorders (5 with medium chain acyl-CoA dehydrogenase deficiency, 3 with very long chain acyl CoA dehydrogenase deficiency, 2 with short chain acyl-CoA dehydrogenase deficiency, 2 with multiple acyl-CoA dehydrogenase deficiency, 1 with carnitine palmitoyl transferase type II, and 1 with carnitine palmitoyl transferase type I). MS/MS is specific for amino acid diseases and fatty acid disorders. GC-MS is specific for detect organic acidemias. And the diagnoses of part of amino acid diseases need the combination of both methods.

  13. Effect of ion entry acceptance conditions on the performance of a quadrupole mass spectrometer operated in upper and lower stability regions

    International Nuclear Information System (INIS)

    Turner, P.; Taylor, S.; Gibson, J.R.

    2005-01-01

    Computer simulation of ion motion in a quadrupole mass spectrometer has been used to examine the effect of initial ion conditions on performance when operated in the first and third zones of the Mathieu stability diagram. Commercial instruments frequently use round electrodes instead of the better-performing hyperbolic electrodes because the cost of manufacturing is lower. However, adverse features are seen when using round electrodes. Here further insight is provided and a possible method of correction is suggested. For the first time, ion origin for the first stability region for a round electrode quadrupole has been reported

  14. LESSONS IN DE NOVO PEPTIDE SEQUENCING BY TANDEM MASS SPECTROMETRY

    Science.gov (United States)

    Medzihradszky, Katalin F.; Chalkley, Robert J.

    2015-01-01

    Mass spectrometry has become the method of choice for the qualitative and quantitative characterization of protein mixtures isolated from all kinds of living organisms. The raw data in these studies are MS/MS spectra, usually of peptides produced by proteolytic digestion of a protein. These spectra are “translated” into peptide sequences, normally with the help of various search engines. Data acquisition and interpretation have both been automated, and most researchers look only at the summary of the identifications without ever viewing the underlying raw data used for assignments. Automated analysis of data is essential due to the volume produced. However, being familiar with the finer intricacies of peptide fragmentation processes, and experiencing the difficulties of manual data interpretation allow a researcher to be able to more critically evaluate key results, particularly because there are many known rules of peptide fragmentation that are not incorporated into search engine scoring. Since the most commonly used MS/MS activation method is collision-induced dissociation (CID), in this article we present a brief review of the history of peptide CID analysis. Next, we provide a detailed tutorial on how to determine peptide sequences from CID data. Although the focus of the tutorial is de novo sequencing, the lessons learned and resources supplied are useful for data interpretation in general. PMID:25667941

  15. Fast Multi-blind Modification Search through Tandem Mass Spectrometry*

    Science.gov (United States)

    Na, Seungjin; Bandeira, Nuno; Paek, Eunok

    2012-01-01

    With great biological interest in post-translational modifications (PTMs), various approaches have been introduced to identify PTMs using MS/MS. Recent developments for PTM identification have focused on an unrestrictive approach that searches MS/MS spectra for all known and possibly even unknown types of PTMs at once. However, the resulting expanded search space requires much longer search time and also increases the number of false positives (incorrect identifications) and false negatives (missed true identifications), thus creating a bottleneck in high throughput analysis. Here we introduce MODa, a novel “multi-blind” spectral alignment algorithm that allows for fast unrestrictive PTM searches with no limitation on the number of modifications per peptide while featuring over an order of magnitude speedup in relation to existing approaches. We demonstrate the sensitivity of MODa on human shotgun proteomics data where it reveals multiple mutations, a wide range of modifications (including glycosylation), and evidence for several putative novel modifications. Based on the reported findings, we argue that the efficiency and sensitivity of MODa make it the first unrestrictive search tool with the potential to fully replace conventional restrictive identification of proteomics mass spectrometry data. PMID:22186716

  16. Proteomic characterization of wheat amyloplasts using identification of proteins by tandem mass spectrometry.

    Science.gov (United States)

    Andon, Nancy L; Hollingworth, Sarah; Koller, Antonius; Greenland, Andrew J; Yates, John R; Haynes, Paul A

    2002-09-01

    We describe the initial characterization of the wheat amyloplast proteome, consisting of the identification and classification of 171 proteins. Whole amyloplasts and purified amyloplast membranes were prepared from wheat (Triticum aestivum). Protein extracts were examined by one-dimensional and two-dimensional electrophoresis, followed by high performance liquid chromatography-tandem mass spectrometry of separated proteins. Tandem mass spectrometry data of individual peptides was then searched by SEQUEST, using a database containing known protein sequences from both wheat and other homologous cereal crops. Using this approach we identified 108 proteins from whole amyloplasts and 63 proteins from purified amyloplast membranes. The majority of protein identifications were derived from protein sequences from cereal crops other than wheat, for which relatively little gene sequence data is available. The highest percentage of protein identifications obtained from any individual species was 46% of the total number of proteins identified, using sequence data found in our proprietary rice (Oryza sativa) genome database.

  17. New Potential Biomarker for Methasterone Misuse in Human Urine by Liquid Chromatography Quadrupole Time of Flight Mass Spectrometry.

    Science.gov (United States)

    Zhang, Jianli; Lu, Jianghai; Wu, Yun; Wang, Xiaobing; Xu, Youxuan; Zhang, Yinong; Wang, Yan

    2016-09-24

    In this study, methasterone urinary metabolic profiles were investigated by liquid chromatography quadrupole time of flight mass spectrometry (LC-QTOF-MS) in full scan and targeted MS/MS modes with accurate mass measurement. A healthy male volunteer was asked to take the drug and liquid-liquid extraction was employed to process urine samples. Chromatographic peaks for potential metabolites were hunted out with the theoretical [M - H](-) as a target ion in a full scan experiment and actual deprotonated ions were studied in targeted MS/MS experiment. Fifteen metabolites including two new sulfates (S1 and S2), three glucuronide conjugates (G2, G6 and G7), and three free metabolites (M2, M4 and M6) were detected for methasterone. Three metabolites involving G4, G5 and M5 were obtained for the first time in human urine samples. Owing to the absence of helpful fragments to elucidate the steroid ring structure of methasterone phase II metabolites, gas chromatography mass spectrometry (GC-MS) was employed to obtain structural information of the trimethylsilylated phase I metabolite released after enzymatic hydrolysis and the potential structure was inferred using a combined MS method. Metabolite detection times were also analyzed and G2 (18-nor-17β-hydroxymethyl-2α, 17α-dimethyl-androst-13-en-3α-ol-ξ-O-glucuronide) was thought to be new potential biomarker for methasterone misuse which can be detected up to 10 days.

  18. Determination of triacylglycerol regioisomers using electrospray ionization-quadrupole ion trap mass spectrometry with a kinetic method.

    Science.gov (United States)

    Leveque, Nathalie L; Acheampong, Akwasi; Heron, Sylvie; Tchapla, Alain

    2012-04-13

    The kinetic method was applied to differentiate and quantify mixtures of regioisomeric triacylglycerols (TAGs) by generating and mass selecting alkali ion bound metal dimeric clusters with a TAG chosen as reference (ref) and examining their competitive dissociations in a quadrupole ion trap mass spectrometer. This methodology readily distinguished pairs of regioisomers (AAB/ABA) such as LLO/LOL, OOP/OPO and SSP/SPS and consequently distinguished sn-1/sn-3, sn-2 substituents on the glycerol backbone. The dimeric complex ions [ref, Li, TAG((AAB and/or ABA))](+) generated by electrospray ionization mass spectrometry were subjected to collision induced dissociation causing competitive loss of either the neutral TAG reference (ref) leading to [Li(AAB and/or ABA)](+) or the neutral TAG molecule (TAG((AAB and/or ABA))) leading to [ref, Li](+). The ratio of the two competitive dissociation rates, defined by the product ion branching ratio (R(iso)), was related via the kinetic method to the regioisomeric composition of the investigated TAG mixture. In this work, a linear correlation was established between composition of the mixture of each TAG regioisomer and the logarithm of the branching ratio for competitive fragmentation. Depending on the availability of at least one TAG regioisomer as standard, the kinetic method and the standard additions method led to the quantitative analysis of natural TAG mixtures. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. New Potential Biomarker for Methasterone Misuse in Human Urine by Liquid Chromatography Quadrupole Time of Flight Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Jianli Zhang

    2016-09-01

    Full Text Available In this study, methasterone urinary metabolic profiles were investigated by liquid chromatography quadrupole time of flight mass spectrometry (LC-QTOF-MS in full scan and targeted MS/MS modes with accurate mass measurement. A healthy male volunteer was asked to take the drug and liquid–liquid extraction was employed to process urine samples. Chromatographic peaks for potential metabolites were hunted out with the theoretical [M − H]− as a target ion in a full scan experiment and actual deprotonated ions were studied in targeted MS/MS experiment. Fifteen metabolites including two new sulfates (S1 and S2, three glucuronide conjugates (G2, G6 and G7, and three free metabolites (M2, M4 and M6 were detected for methasterone. Three metabolites involving G4, G5 and M5 were obtained for the first time in human urine samples. Owing to the absence of helpful fragments to elucidate the steroid ring structure of methasterone phase II metabolites, gas chromatography mass spectrometry (GC-MS was employed to obtain structural information of the trimethylsilylated phase I metabolite released after enzymatic hydrolysis and the potential structure was inferred using a combined MS method. Metabolite detection times were also analyzed and G2 (18-nor-17β-hydroxymethyl-2α, 17α-dimethyl-androst-13-en-3α-ol-ξ-O-glucuronide was thought to be new potential biomarker for methasterone misuse which can be detected up to 10 days.

  20. Comprehensive two-dimensional gas chromatography in combination with rapid scanning quadrupole mass spectrometry in perfume analysis.

    Science.gov (United States)

    Mondello, Luigi; Casillia, Alessandro; Tranchida, Peter Quinto; Dugo, Giovanni; Dugo, Paola

    2005-03-04

    Single column gas chromatography (GC) in combination with a flame ionization detector (FID) and/or a mass spectrometer is routinely employed in the determination of perfume profiles. The latter are to be considered medium to highly complex matrices and, as such, can only be partially separated even on long capillaries. Inevitably, several monodimensional peaks are the result of two or more overlapping components, often hindering reliable identification and quantitation. The present investigation is based on the use of a comprehensive GC (GC x GC) method, in vacuum outlet conditions, for the near to complete resolution of a complex perfume sample. A rapid scanning quadrupole mass spectrometry (qMS) system, employed for the assignment of GC x GC peaks, supplied high quality mass spectra. The validity of the three-dimensional (3D) GC x GC-qMS application was measured and compared to that of GC-qMS analysis on the same matrix. Peak identification, in all applications, was achieved through MS spectra library matching and the interactive use of linear retention indices (LRI).

  1. Targeted analysis with benchtop quadrupole-orbitrap hybrid mass spectrometer: application to determination of synthetic hormones in animal urine.

    Science.gov (United States)

    Kumar, Praveen; Rúbies, Antoni; Centrich, Francesc; Granados, Mercè; Cortés-Francisco, Nuria; Caixach, Josep; Companyó, Ramon

    2013-05-30

    Sensitive and unequivocal determination of analytes/contaminants in complex matrices is a challenge in the field of food safety control. In this study, various acquisition modes (Full MS/AIF, Full MS+tMS/MS, Full MS/dd MS/MS and tSIM/ddMS/MS) and parameters of a quadrupole-orbitrap hybrid mass spectrometer (Q Exactive) were studied in detail. One of the main conclusions has been that, reducing the scan range for Full MS (using the quadrupole) and targeted modes give higher signal-to-noise (S/N) ratios and thereby better detection limits for analytes in matrix. The use of Q Exactive in a complex case, for the confirmatory analysis of hormones in animal urine is presented. A targeted SIM data dependent MS/MS (tSIM/ddMS/MS) acquisition method for determination of eight synthetic hormones (trenbolone, 17α ethinylestradiol, zeranol, stanozolol, dienestrol, diethylstilbestrol, hexestrol, taleranol) and a naturally occurring hormone (zearalenone) in animal urine were optimized to have sensitive precursors from targeted SIM mode and trigger MS/MS scans over the entire chromatograph peak. The method was validated according to EC/657/2002. CCα (decision limit) for the analytes ranged between 0.11 μg L(-1) and 0.69 μg L(-1) and CCβ (detection capability) ranged between 0.29 μg L(-1) and 0.90 μg L(-1). Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Screening newborns for metabolic disorders based on targeted metabolomics using tandem mass spectrometry

    OpenAIRE

    Yoon, Hye-Ran

    2015-01-01

    The main purpose of newborn screening is to diagnose genetic, metabolic, and other inherited disorders, at their earliest to start treatment before the clinical manifestations become evident. Understanding and tracing the biochemical data obtained from tandem mass spectrometry is vital for early diagnosis of metabolic diseases associated with such disorders. Accordingly, it is important to focus on the entire diagnostic process, including differential and confirmatory diagnostic options, and ...

  3. Practical Limitations of Aerosol Separation by a Tandem Differential Mobility Analyzer-Aerosol Particle Mass Analyzer

    OpenAIRE

    Radney, James G.; Zangmeister, Christopher D.

    2016-01-01

    A cavity ring-down spectrometer and condensation particle counter were used to investigate the limitations in the separation of singly and multiply charged aerosol particles by a tandem differential mobility analyzer (DMA) and aerosol particle mass analyzer (APM). The impact of particle polydispersity and morphology was investigated using three materials: nearly-monodisperse polystyrene latex nanospheres (PSL); polydisperse, nearly-spherical ammonium sulfate (AS) and polydisperse lacey fracta...

  4. Rapid methods to determine procyanidins, anthocyanins, theobromine and caffeine in rat tissues by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Serra, Aida; Macià, Alba; Romero, Maria-Paz; Piñol, Carme; Motilva, Maria-José

    2011-06-01

    Rapid, selective and sensitive methods were developed and validated to determine procyanidins, anthocyanins and alkaloids in different biological tissues, such as liver, brain, the aorta vein and adipose tissue. For this purpose, standards of procyanidins (catechin, epicatechin, and dimer B(2)), anthocyanins (cyanidin-3-glucoside and malvidin-3-glucoside) and alkaloids (theobromine, caffeine and theophylline) were used. The methods included the extraction of homogenized tissues by off-line liquid-solid extraction, and then solid-phase extraction to analyze alkaloids, or microelution solid-phase extraction plate for the analysis of procyanidins and anthocyanins. The eluted extracts were then analyzed by ultra-performance liquid chromatography-electrospray ionization-tandem mass spectrometry, using a triple quadrupole as the analyzer. The optimum extraction solution was water/methanol/phosphoric acid 4% (94/4.5/1.5, v/v/v). The extraction recoveries were higher than 81% for all the studied compounds in all the tissues, except the anthocyanins, which were between 50 and 65% in the liver and brain. In order to show the applicability of the developed methods, different rat tissues were analyzed to determine the procyanidins, anthocyanins and alkaloids and their generated metabolites. The rats had previously consumed 1g of a grape pomace extract (to analyze procyanidins and anthocyanins) or a cocoa extract (to analyze alkaloids) per kilogram of body weight. Different tissues were extracted 4h after administration of the respective extracts. The analysis of the metabolites revealed a hepatic metabolism of procyanidins. The liver was the tissue which produced a greater accumulation of these metabolites. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. A microwave plasma torch quadrupole mass spectrometer for monitoring trace levels of lead and cadmium in water.

    Science.gov (United States)

    Zhu, Zhiqiang; Jiang, Tao; Xiong, Xiaohong; Zou, Wei

    2016-08-01

    The microwave plasma torch (MPT) is a low power-consumption and easily operated plasma generator. As an ambient ion source, the MPT can be coupled with various mass spectrometers and applied in real-time analysis of metal elements in water for the demands of environmental control and water quality inspection. We constructed a quadrupole mass spectrometer with an MPT as the ion source to detect directly trace levels of lead and cadmium in water. Without any pretreatments,water samples were first pneumatically nebulized with a desolvation unit, then flowed through the central tube of the MPT and finally entered the plasma. After that, the metal ions produced were introduced into the mass spectrometer to be analyzed via an atmospheric inlet of a stainless steel capillary tube. The MPT mass spectra of lead and cadmium ions were characterized with clear unit isotopic resolution. The sensitivity reached levels of 20 ng/L for lead and 72.7 ng/L for cadmium in water, respectively. The linear response range covered at least 2 orders of magnitude. Moreover, a single aqueous sample could be completely analyzed within 3 minutes, providing reasonably relative standard deviation values. Our results demonstrated that this MPT mass spectrometer is a useful tool for the monitoring of lead and cadmium ions in water, which makes it a potential alternative to ICP-MS, to be used in the fields of environmental control and water quality and foodstuff safety inspection. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  6. Gas chromatography quadrupole time-of-flight mass spectrometry determination of benzotriazole ultraviolet stabilizers in sludge samples.

    Science.gov (United States)

    Casado, J; Rodríguez, I; Carpinteiro, I; Ramil, M; Cela, R

    2013-06-07

    In this research, a simplified procedure for the selective determination of nine benzotriazole UV stabilizers (BUVSs) in sludge from urban sewage treatment plants is presented. Analytes were extracted from the sample using the matrix solid-phase dispersion (MSPD) technique and further determined by gas chromatography (GC) with quadrupole time-of-flight mass spectrometry (QTOF-MS). Highly selective chromatographic records were attained considering a mass window of 0.005Da, centred in the quantification product ion corresponding to each compound. Moreover, the availability of accurate ion product scan MS/MS spectra permitted to confirm the identities of peaks observed in extracted ion MS/MS chromatograms. As a result, a straightforward sample preparation procedure combining extraction and clean-up in the same step, and consuming just 10mL of ethyl acetate, sufficed to deal with complex sludge samples. The developed method attained limits of quantification (LOQs) between 2ngg(-1) and 10ngg(-1), referred to freeze-dried sludge, and recoveries from 70% to 111%, with standard deviations from 2% to 13%. Analysis of sludge samples and certified reference materials confirmed the existence of residues of eight out of nine BUVSs. UV-326, UV-328 and UV-234 displayed the highest occurrence frequencies and individual concentrations above 100ngg(-1) in several samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Classifying wine according to geographical origin via quadrupole-based ICP-mass spectrometry measurements of boron isotope ratios

    Energy Technology Data Exchange (ETDEWEB)

    Coetzee, Paul P. [University of Johannesburg, Department of Chemistry, Johannesburg (South Africa); Vanhaecke, Frank [Institute for Nuclear Sciences, Laboratory of Analytical Chemistry Ghent University, Ghent (Belgium)

    2005-11-01

    The potential of quadrupole-based ICP-MS as a tool for B-isotopic analysis of wines and its usefulness in provenance determinations were assessed. A precision of 0.1-0.25% RSD (corresponding to a relative standard deviation of the mean of three replicate measurements of 0.06-0.12%) was sufficient to establish small differences in the B isotope ratios in wines from different geographical origins. Each sample measurement was bracketed by measurements of a standard and mass bias drift correction made by interpolation. Sample preparation was kept to a minimum to avoid possible fractionation. Dilution of the wine samples by a factor of 100 with 0.65% HNO{sub 3} was found to reduce matrix-induced mass discrimination substantially. Wines from three wine-producing regions, Stellenbosch, Robertson, and Swartland, in the Western Cape Province of South Africa, and wines from specific regions in France (Bergerac) and Italy (Valpolicella) were analyzed by ICP-QMS for their B-isotopic compositions. It was concluded that the {sup 11}B/{sup 10}B ratios can be used to characterize wines from different geographical origins. Average {sup 11}B/{sup 10}B ratios in red wines from South Africa (Stellenbosch), France (Bergerac), and Italy (Valpolicella) were found to differ by between 0.5 and 1.5%. (orig.)

  8. Identification of five Mitragyna alkaloids in urine using liquid chromatography-quadrupole/time of flight mass spectrometry.

    Science.gov (United States)

    Basiliere, Stephanie; Bryand, Kelsie; Kerrigan, Sarah

    2018-03-30

    Mitragyna speciosa (Kratom) is a psychoactive plant that has recently emerged as a recreational drug. Mitragyna alkaloids are not within the scope of traditional forensic toxicology screening methods, which may contribute to under-reporting. Solid phase extraction (SPE) and liquid chromatography-quadrupole/time of flight mass spectrometry (LC-Q/TOF-MS) were used to identify five alkaloids in urine. Target analytes included the two known psychoactive compounds, mitragynine and 7-hydroxymitragynine, in addition to speciociliatine, speciogynine, and paynantheine. Two deuterated internal standards (mitragynine-D 3 and 7-hydroxymitragynine-D 3 ) were employed. Using traditional reversed phase chromatography all compounds and isomers were separated in 10 min. The procedure was validated in accordance with the Scientific Working Group for Forensic Toxicology (SWGTOX) Standard Practices for Method Validation. Extraction efficiencies were 63-96% and limits of quantitation were 0.5-1 ng/mL. Precision, bias and matrix effects were all within acceptable thresholds, with the exception of 7-hydroxymitragynine, which is notably unstable and unsuitable for quantitative analysis. In this paper we present a simultaneous quantitative analytical method for mitragynine, speciociliatine, speciogynine and paynantheine, and a qualitative assay for 7-hydroxymitragynine in urine using high resolution mass spectrometry (HRMS). Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Classifying wine according to geographical origin via quadrupole-based ICP-mass spectrometry measurements of boron isotope ratios

    International Nuclear Information System (INIS)

    Coetzee, Paul P.; Vanhaecke, Frank

    2005-01-01

    The potential of quadrupole-based ICP-MS as a tool for B-isotopic analysis of wines and its usefulness in provenance determinations were assessed. A precision of 0.1-0.25% RSD (corresponding to a relative standard deviation of the mean of three replicate measurements of 0.06-0.12%) was sufficient to establish small differences in the B isotope ratios in wines from different geographical origins. Each sample measurement was bracketed by measurements of a standard and mass bias drift correction made by interpolation. Sample preparation was kept to a minimum to avoid possible fractionation. Dilution of the wine samples by a factor of 100 with 0.65% HNO 3 was found to reduce matrix-induced mass discrimination substantially. Wines from three wine-producing regions, Stellenbosch, Robertson, and Swartland, in the Western Cape Province of South Africa, and wines from specific regions in France (Bergerac) and Italy (Valpolicella) were analyzed by ICP-QMS for their B-isotopic compositions. It was concluded that the 11 B/ 10 B ratios can be used to characterize wines from different geographical origins. Average 11 B/ 10 B ratios in red wines from South Africa (Stellenbosch), France (Bergerac), and Italy (Valpolicella) were found to differ by between 0.5 and 1.5%. (orig.)

  10. Classifying wine according to geographical origin via quadrupole-based ICP-mass spectrometry measurements of boron isotope ratios.

    Science.gov (United States)

    Coetzee, Paul P; Vanhaecke, Frank

    2005-11-01

    The potential of quadrupole-based ICP-MS as a tool for B-isotopic analysis of wines and its usefulness in provenance determinations were assessed. A precision of 0.1-0.25% RSD (corresponding to a relative standard deviation of the mean of three replicate measurements of 0.06-0.12%) was sufficient to establish small differences in the B isotope ratios in wines from different geographical origins. Each sample measurement was bracketed by measurements of a standard and mass bias drift correction made by interpolation. Sample preparation was kept to a minimum to avoid possible fractionation. Dilution of the wine samples by a factor of 100 with 0.65% HNO3 was found to reduce matrix-induced mass discrimination substantially. Wines from three wine-producing regions, Stellenbosch, Robertson, and Swartland, in the Western Cape Province of South Africa, and wines from specific regions in France (Bergerac) and Italy (Valpolicella) were analyzed by ICP-QMS for their B-isotopic compositions. It was concluded that the 11B/10B ratios can be used to characterize wines from different geographical origins. Average 11B/10B ratios in red wines from South Africa (Stellenbosch), France (Bergerac), and Italy (Valpolicella) were found to differ by between 0.5 and 1.5%.

  11. Quantitative Caffeine Analysis Using a Surface Sampling Probe Electrospray Ionization Tandem Mass Spectrometry System

    Energy Technology Data Exchange (ETDEWEB)

    Ford, Michael J [ORNL; Deibel, Michael A. [Earlham College; Tomkins, Bruce A [ORNL; Van Berkel, Gary J [ORNL

    2005-01-01

    Quantitative determination of caffeine on reversed-phase C8 thin-layer chromatography plates using a surface sampling electrospray ionization system with tandem mass spectrometry detection is reported. The thin-layer chromatography/electrospray tandem mass spectrometry method employed a deuterium-labeled caffeine internal standard and selected reaction monitoring detection. Up to nine parallel caffeine bands on a single plate were sampled in a single surface scanning experiment requiring 35 min at a surface scan rate of 44 {mu}m/s. A reversed-phase HPLC/UV caffeine assay was developed in parallel to assess the mass spectrometry method performance. Limits of detection for the HPLC/UV and thin-layer chromatography/electrospray tandem mass spectrometry methods determined from the calibration curve statistics were 0.20 ng injected (0.50 {mu}L) and 1.0 ng spotted on the plate, respectively. Spike recoveries with standards and real samples ranged between 97 and 106% for both methods. The caffeine content of three diet soft drinks (Diet Coke, Diet Cherry Coke, Diet Pepsi) and three diet sport drinks (Diet Turbo Tea, Speed Stack Grape, Speed Stack Fruit Punch) was measured. The HPLC/UV and mass spectrometry determinations were in general agreement, and these values were consistent with the quoted values for two of the three diet colas. In the case of Diet Cherry Coke and the diet sports drinks, the determined caffeine amounts using both methods were consistently higher (by 8% or more) than the literature values.

  12. Development and Application of an MSALL-Based Approach for the Quantitative Analysis of Linear Polyethylene Glycols in Rat Plasma by Liquid Chromatography Triple-Quadrupole/Time-of-Flight Mass Spectrometry.

    Science.gov (United States)

    Zhou, Xiaotong; Meng, Xiangjun; Cheng, Longmei; Su, Chong; Sun, Yantong; Sun, Lingxia; Tang, Zhaohui; Fawcett, John Paul; Yang, Yan; Gu, Jingkai

    2017-05-16

    Polyethylene glycols (PEGs) are synthetic polymers composed of repeating ethylene oxide subunits. They display excellent biocompatibility and are widely used as pharmaceutical excipients. To fully understand the biological fate of PEGs requires accurate and sensitive analytical methods for their quantitation. Application of conventional liquid chromatography-tandem mass spectrometry (LC-MS/MS) is difficult because PEGs have polydisperse molecular weights (MWs) and tend to produce multicharged ions in-source resulting in innumerable precursor ions. As a result, multiple reaction monitoring (MRM) fails to scan all ion pairs so that information on the fate of unselected ions is missed. This Article addresses this problem by application of liquid chromatography-triple-quadrupole/time-of-flight mass spectrometry (LC-Q-TOF MS) based on the MS ALL technique. This technique performs information-independent acquisition by allowing all PEG precursor ions to enter the collision cell (Q2). In-quadrupole collision-induced dissociation (CID) in Q2 then effectively generates several fragments from all PEGs due to the high collision energy (CE). A particular PEG product ion (m/z 133.08592) was found to be common to all linear PEGs and allowed their total quantitation in rat plasma with high sensitivity, excellent linearity and reproducibility. Assay validation showed the method was linear for all linear PEGs over the concentration range 0.05-5.0 μg/mL. The assay was successfully applied to the pharmacokinetic study in rat involving intravenous administration of linear PEG 600, PEG 4000, and PEG 20000. It is anticipated the method will have wide ranging applications and stimulate the development of assays for other pharmaceutical polymers in the future.

  13. Rapid screening and identification of lycodine-type alkaloids in Lycopodiaceae and Huperziaceae plants by ultra-performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Shan, Si-Ming; Luo, Jian-Guang; Pan, Ke; Zou, Hong-Yan; Kong, Ling-Yi

    2016-11-01

    Lycodine-type alkaloids have gained significant interest owing to their unique skeletal characteristics and acetylcholinesterase activity. This study established a rapid and reliable method using ultra-performance liquid chromatography coupled with electrospray ionization quadrupole time-of-flight tandem mass spectrometry (UPLC-ESI-Q/TOF-MS/MS) for comprehensive characterization of lycodine-type alkaloids for the first time. The lycodine-type alkaloids were detected successfully from Lycopodiastrum casuarinoides, Huperzia serrata and Phlegmarirus carinatus in seven plants of the Lycopodiaceae and Huperziaceae families, based on the established characteristic MS fragmentation of five known alkaloids. Furthermore, a total of 13 lycodine-type alkaloids were identified, of which three pairs of isomers were structurally characterized and differentiated. This study further improves mass analysis of lycodine-type alkaloids and demonstrates the superiority of UPLC with a high-resolution mass spectrometer for the rapid and sensitive structural elucidation of other trace active compounds. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  14. Determination of four forms of vitamin B12 and other B vitamins in seawater by liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Heal, Katherine R; Carlson, Laura Truxal; Devol, Allan H; Armbrust, E Virginia; Moffett, James W; Stahl, David A; Ingalls, Anitra E

    2014-11-30

    Vitamin B(12) is an essential nutrient for more than half of surveyed marine algae species, but methods for directly measuring this important cofactor in seawater are limited. Current mass spectrometry methods do not quantify all forms of B(12), potentially missing a significant portion of the B(12) pool. We present a method to measure vitamins B(1), B(2), B(6), B(7) and four forms of B(12) dissolved in seawater. The method entails solid-phase extraction, separation by ultra-performance liquid chromatography, and detection by triple-quadrupole tandem mass spectrometry using stable-isotope-labeled internal standards. We demonstrated the use of this method in the environment by analyzing B(12) concentrations at different depths in the Hood Canal, part of the Puget Sound estuarine system in Washington State. Recovery of vitamin B(12) forms during the preconcentration steps was >71% and the limits of detection were B(12) in seawater at our field site. We developed a method for quantifying four forms of B(12) in seawater by liquid chromatography/mass spectrometry with the option of simultaneous analysis of vitamins B(1), B(2), B(6), and B(7). We validated the method and demonstrated its application in the field. Copyright © 2014 John Wiley & Sons, Ltd.

  15. Chemotaxonomic studies of nine Paris species from China based on ultra-high performance liquid chromatography tandem mass spectrometry and Fourier transform infrared spectroscopy.

    Science.gov (United States)

    Wang, Yuanzhong; Liu, Ehu; Li, Ping

    2017-06-05

    Paris species, which contain steroid saponins, have been used as herb folk medicines in Asia. In the present study, a comprehensive strategy based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) and Fourier transform infrared (FT-IR) spectroscopy was firstly proposed to evaluate the chemotaxonomic relationships of nine Paris species sampled from different geographical regions in China. Principle component analysis (PCA) based on FT-IR data revealed chemical similarities in term of the nine species and geographical regions, indicating the accumulation of metabolites affected by the combination of geographical factors and species. The chemotaxonomic relationships of four species supported the morphological taxonomy and implied ancestry from P. polyphylla. After high-efficiency chromatographic separation, ions trap/time-of-flight mass spectrometry (IT-TOFMS) and triple quadrupole mass spectrometry (QQQ-MS) were used to identify unknown metabolites and simultaneously determine six key compounds (polyphyllin I, II, V, VI, VII and gracillin) in Paris species, respectively. The tentative identification of 22 steroid saponins was indicative of a common biosynthetic pathway in Paris species. Phytoecdysones, gracillin and open-chain steroid saponins were considered as key precursors. According to Pearson's correlation analysis, an insignificant correlation was found between diosgenin-type and pennogenin-type saponins belonging to the same biosynthetic pathways in the current stage. Our results could provide a reasonable foundation for chemotaxonomy or further studies of Paris species. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Rapid identification of polymer additives by atmospheric solid analysis probe with quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Du, Zhenxia; Zhang, Yun; Li, Ailin; Lv, Surong

    2014-10-15

    A method using an atmospheric solid analysis probe (ASAP) combined with quadrupole time-of-flight mass spectrometry (QTOFMS) assisted by a pre-built MS library was found to be efficient in fast and direct analysis of additives for polymers. By this method, sample pretreatment could be eliminated from the additives identification process. Some crucial parameters, such as desolvation gas temperature, corona current, sample cone voltage and collision energy, should be optimized. A MS library of 100 polymer additives, including phenols (Irganox 1010, Irganox 1076), hydroxyl phenyl benzotriazole derivatives (Tinuvin 326, Tinuvin 327, Tinuvin 328), hindered amines (Tinuvin 944, Tinuvin 770) and plasticizers, was built based on the optimized conditions. To verify the application of the MS library, the ASAP-QTOFMS method was applied to identify complex additives, a simulated polypropylene (PP) sample and a real polymethylmethacrylate (PMMA) sample purchased from a local market. By searching the exact mass, and comparing the MS and MS/MS spectra of samples with standards in the MS library, complex additives such as Irganox GX 2921, as well as additives in PP and PMMA samples, could be identified quickly and easily. The determination of mass accuracy increased the confidence of peak identification as well. Moreover, the results also provided information of the characterization for PP and PMMA polymers. A rapid identification method has been developed for polymer additives by ASAP-QTOFMS. A MS library of 100 polymer additives was built by this method. Using ASAP-QTOFMS assisted by the pre-built MS library, polymer additives can be quickly identified. This method was found to be a promising tool in the rapid analysis of additives in polymers and polymer matrices. Copyright © 2014 John Wiley & Sons, Ltd.

  17. A column switching ultrahigh-performance liquid chromatography-tandem mass spectrometry method to determine anandamide and 2-arachidonoylglycerol in plasma samples.

    Science.gov (United States)

    Marchioni, Camila; de Souza, Israel Donizeti; Grecco, Caroline Fernandes; Crippa, José Alexandre; Tumas, Vitor; Queiroz, Maria Eugênia Costa

    2017-05-01

    This study reports a fast, sensitive, and selective column switching ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method to determine the endocannabinoids (eCBs), anandamide (AEA), and 2-arachidonoylglycerol (2-AG) in plasma samples. This bidimensional system used a restricted access media column (RP-8 ADS, 25 mm × 4 mm × 25 μM) in the first dimension and a core-shell Kinetex C18 (100 mm × 2, 1.7 mm × 1 μM) column in the second dimension, followed by detection in a mass spectrometer triple quadrupole (multiple reactions monitoring mode) operating in the positive mode. RP-8 ADS was used for trace enrichment of eCBs (reverse phase partitioning) and macromolecular matrix size exclusion; the core-shell column was used for the chromatographic separation. The column switching UHPLC-MS/MS method presented a linear range spanning from 0.1 ng mL -1 (LOQ) to 6 ng mL -1 for AEA and from 0.04 ng mL -1 (LOQ) to 10 ng mL -1 for 2-AG. Excluding the LLOQ values, the precision assays provided coefficients of variation lower than 8% and accuracy with relative standard error values lower than 14%. Neither carryover nor matrix effects were detected. This high-throughput column switching method compared to conventional methods is time saving as it involves fewer steps, consumes less solvent, and presents lower LLOQ. The column switching UHPLC-MS/MS method was successfully applied to determine AEA and 2-AG in plasma samples obtained from Alzheimer's disease patients. Graphical abstract A column switching ultra high-performance liquid chromatography-tandem mass spectrometry method using RP-8 ADS column and core shell column to determine endocannabinoids in plasma samples.

  18. Magnetic quadrupole and solenoidal spectrometers

    International Nuclear Information System (INIS)

    Laurent, H.; Schapira, J.P.

    1979-01-01

    General optical properties of magnetic quadrupole spectrometers are reviewed, together with experimental purposes for nuclear physics: background reduction, magnetic rigidity filtering for extreme forward angles measurements, light charged particle discrimination, ionic charge state separation, time of flight mass spectrometry and fast collection of radioactive nuclear reaction products. Possibility of alternative devices such as superconducting quadrupoles or solenoid spectrometers are discussed. (Auth.)

  19. A frequency and amplitude scanned quadrupole mass filter for the analysis of high m/z ions

    Science.gov (United States)

    Shinholt, Deven L.; Anthony, Staci N.; Alexander, Andrew W.; Draper, Benjamin E.; Jarrold, Martin F.

    2014-11-01

    Quadrupole mass filters (QMFs) are usually not used to analyze high m/z ions, due to the low frequency resonant circuit that is required to drive them. Here we describe a new approach to generating waveforms for QMFs. Instead of scanning the amplitude of a sine wave to measure the m/z spectrum, the frequency of a trapezoidal wave is digitally scanned. A synchronous, narrow-range (clock using a field programmable gate array. This signal drives integrating amplifiers which generate the trapezoidal waves. For a trapezoidal wave the harmonics can be minimized by selecting the appropriate rise and fall times. To achieve a high resolving power, the digital signal has low jitter, and the trapezoidal waveform is generated with high fidelity. The QMF was characterized with cesium iodide clusters. Singly and multiply charged clusters with z up to +5 were observed. A resolving power of ˜1200 (FWHM) was demonstrated over a broad m/z range. Resolution was lost above 20 000 Th, partly because of congestion due to overlapping multiply charged clusters. Ions were observed for m/z values well in excess of 150 000 Th.

  20. Trace determination of 13 haloacetamides in drinking water using liquid chromatography triple quadrupole mass spectrometry with atmospheric pressure chemical ionization.

    Science.gov (United States)

    Chu, Wenhai; Gao, Naiyun; Yin, Daqiang; Krasner, Stuart W; Templeton, Michael R

    2012-04-27

    The haloacetamides (HAcAms) are disinfection by-products (DBPs) in drinking water which are currently receiving increased scientific attention due to their elevated toxicity relative to regulated disinfection by-products. A simultaneous determination method of 13 HAcAms, combining solid-phase extraction (SPE) enrichment, liquid chromatographic (LC) separation, and triple quadrupole mass spectrometry (tqMS) detection with atmospheric pressure chemical ionization (APCI) using selective reaction monitoring in positive mode, was developed to measure HAcAms, including chlorinated, brominated, and iodinated analogs. Ammonium chloride and Oasis HLB were selected as the dechlorinating reagent and polymeric SPE sorbent of HAcAm samples. The used tqMS apparatus showed higher sensitivity for the studied HAcAms in the APCI mode than electrospray ionization. 13 HAcAms were separated by LC in 9.0 min, and the detection limits ranged from 7.6 to 19.7 ng/L. The SPE-LC/tqMS method was successfully applied to quantify 13 HAcAms in drinking water samples for the first time, and first indentified tribromoacetamide and chloroiodoacetamide as DBPs in drinking water. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Analysis of psychoactive substances in water by information dependent acquisition on a hybrid quadrupole time-of-flight mass spectrometer.

    Science.gov (United States)

    Andrés-Costa, María Jesús; Andreu, Vicente; Picó, Yolanda

    2016-08-26

    Emerging drugs of abuse, belonging to many different chemical classes, are attracting users with promises of "legal" highs and easy access via internet. Prevalence of their consumption and abuse through wastewater-based epidemiology can only be realized if a suitable analytical screening procedure exists to detect and quantify them in water. Solid-phase extraction and ultra-high performance liquid chromatography quadrupole time-of-flight-mass spectrometry (UHPLC-QqTOF-MS/MS) was applied for rapid suspect screening as well as for the quantitative determination of 42 illicit drugs and metabolites in water. Using this platform, we were able to identify amphetamines, tryptamines, piperazines, pyrrolidinophenones, arylcyclohexylamines, cocainics, opioids and cannabinoids. Additionally, paracetamol, carbamazepine, ibersartan, valsartan, sulfamethoxazole, terbumeton, diuron, etc. (including degradation products as 3-hydroxy carbamazepine or deethylterbuthylazine) were detected. This method encompasses easy sample preparation and rapid identification of psychoactive drugs against a database that cover more than 2000 compounds that ionized in positive mode, and possibility to identify metabolites and degradation products as well as unknown compounds. The method for river water, influent and effluents samples was fully validated for the target psychoactive substances including assessment of matrix effects (-88-67.8%), recovery (42-115%), precision (psychoactive drugs biomarkers and other water contaminants is demonstrated. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Verification of protein biomarker specificity for the identification of biological stains by quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Legg, Kevin M; Powell, Roger; Reisdorph, Nichole; Reisdorph, Rick; Danielson, Phillip B

    2017-03-01

    Advances in proteomics technology over the past decade offer forensic serologists a greatly improved opportunity to accurately characterize the tissue source from which a DNA profile has been developed. Such information can provide critical context to evidence and can help to prioritize downstream DNA analyses. Previous proteome studies compiled panels of "candidate biomarkers" specific to each of five body fluids (i.e., peripheral blood, vaginal/menstrual fluid, seminal fluid, urine, and saliva). Here, a multiplex quadrupole time-of-flight mass spectrometry assay has been developed in order to verify the tissue/body fluid specificity the 23 protein biomarkers that comprise these panels and the consistency with which they can be detected across a sample population of 50 humans. Single-source samples of these human body fluids were accurately identified by the detection of one or more high-specificity biomarkers. Recovery of body fluid samples from a variety of substrates did not impede accurate characterization and, of the potential inhibitors assayed, only chewing tobacco juice appeared to preclude the identification of a target body fluid. Using a series of 2-component mixtures of human body fluids, the multiplex assay accurately identified both components in a single-pass. Only in the case of saliva and peripheral blood did matrix effects appear to impede the detection of salivary proteins. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Identification of hyperoside metabolites in rat using ultra performance liquid chromatography/quadrupole-time-of-flight mass spectrometry.

    Science.gov (United States)

    Guo, Jianming; Xue, Caifu; Shang, Er-xin; Duan, Jin-ao; Tang, Yuping; Qian, Dawei

    2011-07-01

    In this paper, ultra performance liquid chromatography (UPLC)/quadrupole-time-of-flight mass spectrometry (QTOF) with automated data analysis software (Metabolynx™) were applied for fast analysis of hyperoside metabolites in rat after intravenous administration. MS(E) was used for simultaneous acquisition of precursor ion information and fragment ion data at high and low collision energy in one analytical run, which facilitated the fast structural characterization of 12 metabolites in rat plasma, urine and bile. The results indicated that methylation, sulfation and glucuronidation were the major metabolic pathways of hyperoside in vivo, and among them, 3'-O-methyl-hyperoside was confirmed by matching its fragmentation patterns with standard compound. The present study provided important information about the metabolism of hyperoside which will be helpful for fully understanding the mechanism of this compound's action. Furthermore, this work demonstrated the potential of the UPLC/QTOFMS approach using Metabolynx for fast and automated identification of metabolites of natural product. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Fast analysis of triterpenoids in Ganoderma lucidum spores by ultra-performance liquid chromatography coupled with triple quadrupole mass spectrometry.

    Science.gov (United States)

    Yan, Zhou; Xia, Bing; Qiu, Ming Hua; Li Sheng, Ding; Xu, Hong Xi

    2013-11-01

    A rapid and reliable method was established for simultaneous determination of main triterpenoids in Ganoderma lucidum spores using ultra-high-performance liquid chromatography coupled with triple quadrupole mass spectrometry (UPLC-TQ-MS). The established method was validated in terms of linearity, sensitivity, precision, accuracy and stability, and was successfully applied to determine the contents of 10 main triterpenoids in different batches of G. lucidum spores. The analysis results showed that moderate levels of triterpenoids were found in G. lucidum spores. In addition, a MS full scan with a daughter ion scan experiment was performed to identify the potential derivatives of triterpenoids present in G. lucidum spores. As a result, a total of 22 triterpenoids from different G. lucidum spores were unequivocally or tentatively identified via comparisons with authentic standards and literatures. This method provides both qualitative and quantitative results without the need for repetitive UPLC-MS analyses, thereby increasing efficiency and productivity, making it suitable for high-throughput applications. Copyright © 2013 John Wiley & Sons, Ltd.

  5. Profiling the Metabolism of Astragaloside IV by Ultra Performance Liquid Chromatography Coupled with Quadrupole/Time-of-Flight Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Xu-Dong Cheng

    2014-11-01

    Full Text Available Astragaloside IV is a compound isolated from the Traditional Chinese Medicine Astragalus membranaceus, that has been reported to have bioactivities against cardiovascular disease and kidney disease. There is limited information on the metabolism of astragaloside IV, which impedes comprehension of its biological actions and pharmacology. In the present study, an ultra-performance liquid chromatography coupled with quadrupole/time-of-flight mass spectrometry (UPLC-Q-TOF-MS/MS-based approach was developed to profile the metabolites of astragaloside IV in rat plasma, bile, urine and feces samples. Twenty-two major metabolites were detected. The major components found in plasma, bile, urine and feces included the parent chemical and phases I and II metabolites. The major metabolic reactions of astragaloside IV were hydrolysis, glucuronidation, sulfation and dehydrogenation. These results will help to improve understanding the metabolism and reveal the biotransformation profiling of astragaloside IV in vivo. The metabolic information obtained from our study will guide studies into the pharmacological activity and clinical safety of astragaloside IV.

  6. Quantitative analysis of cytokinins in plants by liquid chromatography single-quadrupole mass spectrometry

    Czech Academy of Sciences Publication Activity Database

    Novák, Ondřej; Tarkowski, Petr; Tarkowská, Danuše; Doležal, Karel; Lenobel, René; Strnad, Miroslav

    2003-01-01

    Roč. 480, č. 2 (2003), s. 207ů218 ISSN 0003-2670 R&D Projects: GA ČR GA522/01/0275 Grant - others: Volkswagen Stiftung(DE) I/76 865 Institutional research plan: CEZ:AV0Z5038910; CEZ:MSM 153100008 Keywords : Liquid chromatography mass spectrometry * Cytokinins Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 2.210, year: 2003

  7. [Determination of Total Sulfur Dioxide in Chinese Herbal Medicines via Triple Quadrupole Inductively Coupled Plasma Mass Spectrometry].

    Science.gov (United States)

    Wang, Xiao-wei; Liu, Jing-fu; Guan, Hong; Wang, Xiao-yan; Shag, Bing; Zhang, Jing; Liu, Li-ping; Zhang, Ni-na

    2016-02-01

    As an important treatment method, sulfur fumigation plays an essential role in the production and preservation of traditional Chinese herbal medicines. Although there is strict regulation on the use of sulfur dioxide, the abuse of sulfur dioxide still occurred from time to time. And the public faces a high risk of exposure. Because of the poor precision and tedious preparation procedures of traditional recommended titration, the accurate and convenient determination of sulfur dioxide in Chinese herbal medicines is still a critical analytical task for medicines safety and the public health. In this study, an accurate, high-throughput, and convenient method for the absolute determination of SO₂ in Chinese herbal medicines based on triple quadrupole inductively coupled plasma mass spectrometry (ICP-MS/MS) technique is developed. The study compared the quantitative ability for sulfur when the ICP-MS operated under traditional single quadrupole (QMS) mode and novel triple quadrupole (MS/MS) mode with three Reaction/Collision cell condition (no gas, helium, and oxygen). The result indicated that when the concentration of sulfate ranging from 0.5 to 100 mg · L⁻¹, isotopic ³⁴S can be selected as quantitative ion either the ICP-MS operated under the QMS mode or MS/MS mode. The use of helium in the Reaction/Collision cell decreased the single intensity of background ions. Better than QMS mode, the MS/MS mode can effectively reduced background interference. But there are no significant differences about the linear range and limit of detection. However, when the ICP-MS operated under MS/MS mode and oxygen was used as reaction gas in the Reaction/Collision cell, the ICP-MS/MS provided an interference-free performance, the linear range and limit of detection improved significantly. Either ³²S or ³⁴S exhibits an excellent linearity (r > 0.999) over the concentration range of 0.02-100 mg · L⁻¹, with a limit of detection of 5.48 and 9.76 µg · L⁻¹ for

  8. Ring positional differentiation of isomeric N-alkylated fluorocathinones by gas chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Westphal, Folker; Junge, Thomas

    2012-11-30

    In analogy to our previously published procedure for the differentiation of regioisomeric fluoroamphetamines a method was developed, to differentiate ring positional isomeric fluorocathinones by product ion spectrometry of ions generated by chemical ionization (CI) under GC-MS conditions using methane as reagent gas. N-alkylated ortho-, meta- and para-fluorocathinones could be unequivocally differentiated by product ion spectrometry of the hydrogen fluoride loss ions [M+H-HF](+) using a triple quadrupole mass spectrometer with argon as collision gas under normalized collision conditions. This method enables the differentiation of ring positional isomers of fluorocathinones even in complex mixtures and low concentrations. The applicability of the method was shown by the analysis of synthesized N-alkylated ortho-, meta- and para-fluorocathinones and seized designer drug mixtures. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  9. Accurate Mass GC/LC-Quadrupole Time of Flight Mass Spectrometry Analysis of Fatty Acids and Triacylglycerols of Spicy Fruits from the Apiaceae Family

    Directory of Open Access Journals (Sweden)

    Thao Nguyen

    2015-12-01

    Full Text Available The triacylglycerol (TAG structure and the regio-stereospecific distribution of fatty acids (FA of seed oils from most of the Apiaceae family are not well documented. The TAG structure ultimately determines the final physical properties of the oils and the position of FAs in the TAG molecule affects the digestion; absorption and metabolism; and physical and technological properties of TAGs. Fixed oils from the fruits of dill (Anethum graveolens, caraway (Carum carvi, cumin (Cuminum cyminum, coriander (Coriandrum sativum, anise (Pimpinella anisum, carrot (Daucus carota, celery (Apium graveolens, fennel (Foeniculum vulgare, and Khella (Ammi visnaga, all from the Apiaceae family, were extracted at room temperature in chloroform/methanol (2:1 v/v using percolators. Crude lipids were fractionated by solid phase extraction to separate neutral triacylglycerols (TAGs from other lipids components. Neutral TAGs were subjected to transesterification process to convert them to their corresponding fatty acids methyl esters (FAMES using 1% boron trifluoride (BF3 in methanol. FAMES were analyzed by gas chromatography-quadrupole time of flight (GC-QTOF mass spectrometry. Triglycerides were analyzed using high performance liquid chromatography-quadrupole time of flight (LC-QTOF mass spectrometry. Petroselinic acid was the major fatty acid in all samples ranging from 57% of the total fatty acids in caraway up to 82% in fennel. All samples contained palmitic (16:0, palmitoleic (C16:1n-9, stearic (C18:0, petroselinic (C18:1n-12, linoleic (C18:2n-6, linolinic (18:3n-3, and arachidic (C20:0 acids. TAG were analyzed using LC-QTOF for accurate mass identification and mass spectrometry/mass spectrometry (MS/MS techniques for regiospesific elucidation of the identified TAGs. Five major TAGs were detected in all samples but with different relative concentrations in all of the tested samples. Several other TAGs were detected as minor components and were present in some

  10. Chemical material basis study of Xuefu Zhuyu decoction by ultra-performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry

    Directory of Open Access Journals (Sweden)

    Lei Zhang

    2015-12-01

    Full Text Available Xuefu Zhuyu decoction, a classic prescription in traditional Chinese medicine, has been widely used in the clinical treatment of cardiovascular and cerebrovascular diseases. In order to profile the chemical material basis of this formula, an ultra-performance liquid chromatography (UPLC coupled with quadrupole time-of-flight mass spectrometry (Q/TOF MS method has been established for rapid separation and structural characterization of compounds in the decoction. As a result, 103 compounds including phenolic acids, spermidines, C-glycosyl quinochalcones, terpenoids, flavonoids, saponins, and others were detected; 35 of them were unambiguously identified, and 68 were tentatively characterized by comparing the retention time, MS data, characteristic MS fragmentation pattern and retrieving the literature. In conclusion, the UPLC coupled with quadrupole time-of-flight mass spectrometry method developed in this work is an efficient approach to perform chemical material basis studies of traditional Chinese medicine formulae.

  11. Gas chromatography/chemical ionization triple quadrupole mass spectrometry analysis of anabolic steroids: ionization and collision-induced dissociation behavior.

    Science.gov (United States)

    Polet, Michael; Van Gansbeke, Wim; Van Eenoo, Peter; Deventer, Koen

    2016-02-28

    The detection of new anabolic steroid metabolites and new designer steroids is a challenging task in doping analysis. Switching from electron ionization gas chromatography triple quadrupole mass spectrometry (GC/EI-MS/MS) to chemical ionization (CI) has proven to be an efficient way to increase the sensitivity of GC/MS/MS analyses and facilitate the detection of anabolic steroids. CI also extends the possibilities of GC/MS/MS analyses as the molecular ion is retained in its protonated form due to the softer ionization. In EI it can be difficult to find previously unknown but expected metabolites due to the low abundance or absence of the molecular ion and the extensive (and to a large extent unpredictable) fragmentation. The main aim of this work was to study the CI and collision-induced dissociation (CID) behavior of a large number of anabolic androgenic steroids (AAS) as their trimethylsilyl derivatives in order to determine correlations between structures and CID fragmentation. Clarification of these correlations is needed for the elucidation of structures of unknown steroids and new metabolites. The ionization and CID behavior of 65 AAS have been studied using GC/CI-MS/MS with ammonia as the reagent gas. Glucuronidated AAS reference standards were first hydrolyzed to obtain their free forms. Afterwards, all the standards were derivatized to their trimethylsilyl forms. Full scan and product ion scan analyses were used to examine the ionization and CID behavior. Full scan and product ion scan analyses revealed clear correlations between AAS structure and the obtained mass spectra. These correlations were confirmed by analysis of multiple hydroxylated, methylated, chlorinated and deuterated analogs. AAS have been divided into three groups according to their ionization behavior and into seven groups according to their CID behavior. Correlations between fragmentation and structure were revealed and fragmentation pathways were postulated. Copyright © 2016 John Wiley

  12. Determination of cyanuric acid residues in catfish, trout, tilapia, salmon and shrimp by liquid chromatography-tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Karbiwnyk, Christine M. [Animal Drugs Research Center, U.S. Food and Drug Administration, P.O. Box 25087, Denver, CO 80225-0087 (United States)], E-mail: christine.karbiwnyk@fda.hhs.gov; Andersen, Wendy C.; Turnipseed, Sherri B. [Animal Drugs Research Center, U.S. Food and Drug Administration, P.O. Box 25087, Denver, CO 80225-0087 (United States); Storey, Joseph M.; Madson, Mark R. [Denver District Laboratory, U.S. Food and Drug Administration, P.O. Box 25087, Denver, CO 80225-0087 (United States); Miller, Keith E. [Center for Veterinary Medicine, U.S. Food and Drug Administration, 8401 Muirkirk Road, Laurel, MD 20708 (United States); Gieseker, Charles M.; Miller, Ron A.; Rummel, Nathan G.; Reimschuessel, Renate [University of Denver, Department of Chemistry and Biochemistry, Denver, CO 80208 (United States)

    2009-04-01

    In May 2007, investigators discovered that waste material from the pet food manufacturing process contaminated with melamine (MEL) and/or cyanuric acid (CYA) had been added to hog and chicken feeds. At this time, investigators also learned that adulterated wheat gluten had been used in the manufacture of aquaculture feeds. Concern that the contaminated feed had been used in aquaculture and could enter the human food supply prompted the development of a method for the determination of CYA residues in the edible tissues of fish and shrimp. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) was employed as a sensitive technique for the analysis of CYA in catfish, tilapia, salmon, trout and shrimp tissue. CYA was extracted from ground fish or shrimp with an acetic acid solution, defatted with hexane, and isolated with a graphitic carbon black solid-phase extraction column. Residues were separated from matrix components using a porous graphitic carbon LC column, and then analyzed with electrospray ionization in negative ion mode on a triple quadrupole mass spectrometer. Selective reaction monitoring was performed on the [M-H]{sup -}m/z 128 ion resulting in the product ions m/z 85 and 42. Recoveries from catfish, tilapia and trout fortified with 10-100 {mu}g kg{sup -1} of CYA averaged 67% with a relative standard deviation (R.S.D.) of 18% (n = 107). The average method detection limit (MDL) for catfish, tilapia and trout is 3.5 {mu}g kg{sup -1}. An internal standard, {sup 13}C{sub 3}-labeled CYA, was used in the salmon and shrimp extractions. Average recovery of CYA from salmon was 91% (R.S.D. = 15%, n = 18) with an MDL of 7.4 {mu}g kg{sup -1}. Average recovery of CYA from shrimp was 85% (R.S.D. = 10%, n = 13) with an MDL of 3.5 {mu}g kg{sup -1}.

  13. Quantitative analysis of phytosterols in edible oils using APCI liquid chromatography-tandem mass spectrometry

    Science.gov (United States)

    Mo, Shunyan; Dong, Linlin; Hurst, W. Jeffrey; van Breemen, Richard B.

    2014-01-01

    Previous methods for the quantitative analysis of phytosterols have usually used GC-MS and require elaborate sample preparation including chemical derivatization. Other common methods such as HPLC with absorbance detection do not provide information regarding the identity of the analytes. To address the need for an assay that utilizes mass selectivity while avoiding derivatization, a quantitative method based on LC-tandem mass spectrometry (LC-MS-MS) was developed and validated for the measurement of six abundant dietary phytosterols and structurally related triterpene alcohols including brassicasterol, campesterol, cycloartenol, β-sitosterol, stigmasterol, and lupeol in edible oils. Samples were saponified, extracted with hexane and then analyzed using reversed phase HPLC with positive ion atmospheric pressure chemical ionization tandem mass spectrometry and selected reaction monitoring. The utility of the LC-MS-MS method was demonstrated by analyzing 14 edible oils. All six compounds were present in at least some of the edible oils. The most abundant phytosterol in all samples was β-sitosterol, which was highest in corn oil at 4.35 ± 0.03 mg/g, followed by campesterol in canola oil at 1.84 ± 0.01 mg/g. The new LC-MS-MS method for the quantitative analysis of phytosterols provides a combination of speed, selectivity and sensitivity that exceed those of previous assays. PMID:23884629

  14. Analysis of xyloglucans by ambient chloride attachment ionization tandem mass spectrometry.

    Science.gov (United States)

    Vinueza, Nelson R; Gallardo, Vanessa A; Klimek, John F; Carpita, Nicholas C; Kenttämaa, Hilkka I

    2013-10-15

    Xyloglucan oligomers obtained upon enzyme digestion from Hymenaea courbaril, Arabidopsis Columbia-0 and mur3 were ionized and analyzed by using chloride anion attachment electrospray ionization (ESI) and tandem mass spectrometry. MW determination and structural elucidation of several xyloglucan oligomers was performed directly from the mixture solutions without sample pretreatment or derivatization. Sodium cation attachment was used to determine the number of xyloglucans present in the mixtures and their MWs. However, tandem mass spectrometry results showed that structure elucidation based on the sodium adducts is ambiguous. Chloride anion also forms stable adducts with these xyloglucans upon ESI. These adducts can be readily identified due to the chlorine isotope pattern. The mass spectral profile of xyloglucans obtained for the mixtures matches the HPAEC results, thus validating this methodology for the determination of the xyloglucan composition and the MW of each xyloglucan. Upon collisional activation in MS(2) experiments, the chloride anion adducts readily lose HCl, which helps verify the molecular weight of each xyloglucan. Isolating the resulting anion (deprotonated oligomer) and subjecting it to further collision-activated dissociation experiments (MS(n); n=3-4) yields useful structural information that allows the differentiation between isomeric anions and hence determination of the sequence of the xyloglucan oligomers. The deprotonated oligomers fragment by a stepwise loss of sugar units from the reducing end. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

  15. Applications of Tandem Mass Spectrometry in the Structure Determination of Permethylated Sialic Acid-containing Oligosaccharides

    International Nuclear Information System (INIS)

    Yoo, Eun Sun; Yoon, In Mo

    2005-01-01

    Sets of sialic acid-containing trisaccharides having different internal and terminal linkages have been synthesized to develop a sensitive method for analysis of the reducing terminal linkage positions. The trisaccharides, sialyl(α 2-3)Gal(β 1-3)GalNAc and sialyl(α 2-3)Gal(β 1-X)GlcNAc where X=3, 4 and 6, were synthesized and examined using electrospray ionization (ESI)-collision induced dissociation (CID) tandem mass spectrometry (MS/MS). The compounds chosen for this study are related to terminal groups likely to be found on polylactosamine-like glycoproteins and glycolipids which occur on the surface of mammalian cells. The purpose of this study is to develop tandem mass spectrometral methods to determine detailed carbohydrate structures on permethylated or partially methylated oligosaccharides for future applications on biologically active glycoconjugates and to exploit a faster method of synthesizing a series of structural isomeric oligosaccharides to be used for further mass spectrometry and instrumental analysis

  16. The fragmentation mechanism of five-membered lactones by electrospray ionisation tandem mass spectrometry

    Science.gov (United States)

    Crotti, Antônio E. M.; Fonseca, Tatiana; Hong, Hui; Staunton, James; Galembeck, Sérgio E.; Lopes, Norberto P.; Gates, Paul J.

    2004-04-01

    A series of five-membered lactones (both saturated and unsaturated) and a lactam were analysed by electrospray ionisation tandem (ESI-MS/MS) and sequential mass spectrometry (ESI-MSn). It was observed that the main fragment ions were derived from neutral losses of CO and/or H2O (NH3 for the lactam). The fragmentation pathways followed are rationalised in terms of the resulting carbocation stability and the energy of the possible fragment ions, calculated by the CBS-Q composite method.

  17. Hybrid Quadrupole-Orbitrap mass spectrometry for quantitative measurement of quorum sensing inhibition.

    Science.gov (United States)

    Todd, Daniel A; Zich, David B; Ettefagh, Keivan A; Kavanaugh, Jeffrey S; Horswill, Alexander R; Cech, Nadja B

    2016-08-01

    Drug resistant bacterial infections cause significant morbidity and mortality worldwide, and new strategies are needed for the treatment of these infections. The anti-virulence approach, which targets non-essential virulence factors in bacteria, has been proposed as one way to combat the problem of antibiotic resistance. Virulence in methicillin-resistant Staphylococcus aureus (MRSA) and many other Gram-positive bacterial pathogens is controlled by the quorum sensing system. Thus, there is excellent therapeutic potential for compounds that target this system. With this project, we have developed and validated a novel approach for measuring quorum sensing inhibition in vitro. Ultraperformance liquid chromatography coupled to mass spectrometry (UPLC-MS) was employed to directly measure one of the important outputs of the quorum sensing system in MRSA, auto-inducing peptide I (AIP I) in bacterial cultures. The method for AIP detection was validated and demonstrated limits of detection and quantification of range of 0.0035μM and 0.10μM, respectively. It was shown that the known quorum sensing inhibitor ambuic acid inhibited AIP I production by a clinically relevant strain of MRSA, with an IC50 value of 2.6±0.2μM. The new method performed similarly to previously published methods using GFP reporter assays, but has the advantage of being applicable without the need for engineering of a reporter strain. Additionally, the mass spectrometry-based method could be applicable in situations where interference by the inhibitor prevents the application of fluorescence-based methods. Copyright © 2016. Published by Elsevier B.V.

  18. Differentiation of three pairs of Boc-beta,gamma- and gamma,beta-hybrid peptides by electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Ramesh, V; Srinivas, R; Sharma, G V M; Jayaprakash, P; Kunwar, A C

    2008-09-01

    A new series of Boc-N-beta(3), gamma(4)-/gamma(4), beta(3)-isomeric hybrid peptides (containing repeats of beta(3)-Caa and gamma(4)-Caa's, Caa = C-linked carbo beta(3)-/gamma(4)-amino acids derived from D-xylose) have been differentiated by both positive and negative ion electrospray ionization (ESI) ion-trap and high resolution quadrupole time-of-flight/tandem mass spectrometry (Q-TOF MS/MS). MS(n) of protonated isomeric peptides and [M+H-Boc+H](+) produce characteristic fragmentation involving the peptide backbone, the Boc-group, and the side chain. The positional isomers are differentiated from one another by the presence of y(n)(+), b(n)(+), and other fragment ions of different m/z values. It is observed that the peptides with beta-Caa at the N-terminus produce extensive fragmentation, whereas gamma-Caa gave rise to much less fragmentation. Peptides with gamma-Caa at the N-terminus lose NH(3), whereas this process is absent for the carbopeptides with beta-Caa at the N-terminus. Two pairs of dipeptide diastereomers are clearly differentiated by the collision-induced dissociation (CID) of their protonated molecules. The loss of 2-methylprop-1-ene is more pronounced for Boc-NH-(R)-beta-Caa-(R)-gamma-Caa-OCH(3) (6) and Boc-NH-(R)-gamma-Caa-(R)-beta-Caa-OCH(3) (12), whereas it is insignificant or totally absent for its protonated diastereomeric pair Boc-NH-(S)-beta-Caa-(S)-gamma-Caa-OCH(3) (1) and Boc-NH-(S)-gamma-Caa-(S)-beta-Caa-OCH(3) (7). Further, ESI negative ion tandem mass spectrometry has also been found to be useful for differentiating these isomeric peptide acids.

  19. Characterization of aromatic organosulfur model compounds relevant to fossil fuels by using atmospheric pressure chemical ionization with CS2 and high-resolution tandem mass spectrometry.

    Science.gov (United States)

    Tang, Weijuan; Sheng, Huaming; Jin, Chunfen; Riedeman, James S; Kenttämaa, Hilkka I

    2016-04-15

    The chemistry of desulfurization involved in processing crude oil is greatly dependent on the forms of sulfur in the oil. Sulfur exists in different chemical bonding environments in fossil fuels, including those in thiophenes and benzothiophenes, thiols, sulfides, and disulfides. In this study, the fragmentation behavior of the molecular ions of 17 aromatic organosulfur compounds with various functionalities was systematically investigated by using high-resolution tandem mass spectrometry. Multiple-stage tandem mass spectrometric experiments were carried out using a linear quadrupole ion trap (LQIT) equipped with an atmospheric pressure chemical ionization (APCI) source. (+)APCI/CS2 was used to generate stable dominant molecular ions for all the compounds studied except for three sulfides that also showed abundant fragment ions. The LQIT coupled with an orbitrap mass spectrometer was used for elemental composition analysis, which facilitated the identification of the neutral molecules lost during fragmentation. The characteristic fragment ions generated in MS(2) and MS(3) experiments provide clues for the chemical bonding environment of sulfur atoms in the examined compounds. Upon collision-induced dissociation (CID), the molecular ions can lose the sulfur atom in a variety of ways, including as S (32 Da), HS(•) (33 Da), H2 S (34 Da), CS (44 Da), (•) CHS (45 Da) and CH2 S (46 Da). These neutral fragments are not only indicative of the presence of sulfur, but also of the type of sulfur present in the compound. Generally, losses of HS(•) and H2 S were found to be associated with compounds containing saturated sulfur functionalities, while losses of S, CS and (•) CHS were more common for heteroaromatic sulfur compounds. High-resolution tandem mass spectrometry with APCI/CS2 ionization is a viable approach to determining the types of organosulfur compounds. It can potentially be applied to analysis of complex mixtures, which is beneficial to improving the

  20. Liquid chromatography tandem mass spectrometry determination of chemical markers and principal component analysis of Vitex agnus-castus L. fruits (Verbenaceae) and derived food supplements.

    Science.gov (United States)

    Mari, Angela; Montoro, Paola; Pizza, Cosimo; Piacente, Sonia

    2012-11-01

    A validated analytical method for the quantitative determination of seven chemical markers occurring in a hydroalcoholic extract of Vitex agnus-castus fruits by liquid chromatography electrospray triple quadrupole tandem mass spectrometry (LC/ESI/(QqQ)MSMS) is reported. To carry out a comparative study, five commercial food supplements corresponding to hydroalcoholic extracts of V. agnus-castus fruits were analysed under the same chromatographic conditions of the crude extract. Principal component analysis (PCA), based only on the variation of the amount of the seven chemical markers, was applied in order to find similarities between the hydroalcoholic extract and the food supplements. A second PCA analysis was carried out considering the whole spectroscopic data deriving from liquid chromatography electrospray linear ion trap mass spectrometry (LC/ESI/(LIT)MS) analysis. High similarity between the two PCA was observed, showing the possibility to select one of these two approaches for future applications in the field of comparative analysis of food supplements and quality control procedures. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Ultra-high performance liquid chromatography-tandem mass spectrometry in high-throughput confirmation and quantification of 34 anabolic steroids in bovine muscle.

    Science.gov (United States)

    Vanhaecke, Lynn; Vanden Bussche, Julie; Wille, Klaas; Bekaert, Karen; De Brabander, Hubert F

    2011-08-26

    An ultra-high performance liquid chromatography tandem mass spectrometry multi-residue method for the determination of 34 anabolic steroids (10 estrogens including stilbenes, 14 androgens and 10 gestagens) in meat of bovine origin is reported. The extraction and clean-up procedure involved homogenization with methanol, defatting with hexane, liquid/liquid extraction with diethylether and finally SPE clean-up with coupled Si and NH(2) cartridges. The analytes were separated on a 1.9 μm Hypersil Gold column (100×2.1 mm) and quantified on a triple quadrupole mass spectrometer (TSQ Vantage) operating simultaneously in both positive and negative atmospheric pressure chemical ionisation (APCI) modes. This analytical procedure was subsequently validated according to EU criteria (CD 2002/657/EC), resulting in decision limits and detection capabilities ranging between 0.04 and 0.88 μg kg(-1) and 0.12 and 1.9 μg kg(-1), respectively. The method obtained for all, natural and synthetic steroids, adequate precisions and intra-laboratory reproducibilities (relative standard deviation below 20%), and the linearity ranged between 0.991 and 0.999. The performance characteristics fulfill the recommended concentrations fixed by the Community Reference Laboratories. The developed analysis is sensitive, and robust and therefore useful for confirmation and quantification of anabolic steroids for research purposes and residue control programs. Copyright © 2010 Elsevier B.V. All rights reserved.

  2. Investigation of the effect of plasma albumin levels on regorafenib-induced hepatotoxicity using a validated liquid chromatography-tandem mass spectrometry method.

    Science.gov (United States)

    Pang, Yi Yun; Tan, Yeong Lan; Ho, Han Kiat

    2017-09-01

    Regorafenib is an oral multikinase inhibitor indicated for metastatic colorectal cancer and gastrointestinal stromal tumour. Due to its extensive plasma protein binding and low calculated hepatic extraction ratio, the hepatotoxicity observed with usage of the drug may be related to its plasma exposure. To investigate the highly dynamic free:bound drug concentration for regorafenib in the plasma, a bioanalytical liquid chromatography-tandem mass spectrometric assay was developed and validated in human plasma. The concentration range of the assay was 2-1000ng/mL. Sample preparation was via protein precipitation using acetonitrile with sorafenib as the internal standard. The supernatant was injected into an ultra-performance liquid chromatographic system coupled to a triple quadrupole mass spectrometer. The analytes were separated on an AQUITY UPLC BEH C 18 column (120Å, 1.7μm, 2.1mm×50mm) and eluted with a gradient elution system. The ions were detected in multiple reaction monitoring mode. The linearity, lower limit of quantification, intra-day and inter-day precision and accuracy conformed to FDA guidelines. The validated method was successfully applied to determine the effect of albumin levels in plasma on the extent of protein binding of regorafenib. The results indicated that physiologically-relevant levels of albumin were found to have no significant effect on the extent of protein binding of regorafenib, hence imposing minimal effect on drug disposition. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. A validated liquid chromatography tandem mass spectrometry method for quantification of erlotinib, OSI-420 and didesmethyl erlotinib and semi-quantification of erlotinib metabolites in human plasma.

    Science.gov (United States)

    Svedberg, Anna; Gréen, Henrik; Vikström, Anders; Lundeberg, Joakim; Vikingsson, Svante

    2015-03-25

    A liquid chromatography tandem mass spectrometry method was developed and validated for quantification of erlotinib and its metabolites in human plasma. The method is suitable for therapeutic drug monitoring and pharmacokinetic studies. The substances were extracted using protein precipitation, separated on a BEH XBridge C18 column (100 ×2.1 mm, 1.7 μm) by gradient elution at 0.7 mL/min of acetonitrile and 5 mM ammonium acetate. The concentration was determined using a Waters Xevo triple quadrupole mass spectrometer in a multi reaction monitoring mode. The total run time was 7 min. Deuterated erlotinib and OSI-597 were used as internal standard for erlotinib and its metabolites, respectively. Erlotinib, OSI-420 and didesmethyl erlotinib were quantified in the concentration range 25-5000 ng/mL, 0.5-500 ng/mL and 0.15-10 ng/mL, respectively. Precision and accuracy was OSI-420 at LLOQ (17%). Extraction recovery was above 89%, 99% and 89% for erlotinib, OSI-420 and didesmethyl erlotinib, respectively. The human liver microsomes generated 14 metabolites, three of them not previously reported. Twelve metabolites were measured semi-quantitatively and validated with respect to selectivity, precision and stability. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Pharmacokinetic study of 14-(3-methylbenzylmatrine and 14-(4-methylbenzylmatrine in rat plasma using liquid chromatography-tandem mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Minjie Jiang

    Full Text Available A rapid, sensitive and selective high-performance liquid chromatography-tandem mass spectrometric method (HPLC-MS was developed and validated to determine the 14-(3-methylbenzylmatrine (3MBM and 14-(4-methylbenzylmatrine (4MBM levels in rat plasma in the present study. The analytes were separated using a C18 column (1.9 μm, 2.1 mm × 100 mm equipped with a Security Guard C18 column (5 μm, 2.1 mm × 10 mm, followed by detection via triple-quadrupole mass spectrometry using an electrospray ionization (ESI source. Sample pretreatment involved one-step protein precipitation with isopropanol:ethyl acetate (v/v, 25:75, and pseudoephedrine hydrochloride was used as an internal standard. The method was linear in the concentration range of 5-2000 ng/ml for both compounds. The intra-day and inter-day relative standard deviations (RSDs were less than 15%, and all relative errors (REs were within 15%. The proposed method enables the unambiguous identification and quantification of these two compounds in vivo. This study is the first to determine the 3MBM and 4MBM levels in rat plasma after oral administration of these compounds. These results provide a meaningful basis for evaluating the clinical applications of these medicines.

  5. UV photodissociation action spectroscopy of haloanilinium ions in a linear quadrupole ion trap mass spectrometer.

    Science.gov (United States)

    Hansen, Christopher S; Kirk, Benjamin B; Blanksby, Stephen J; O'Hair, Richard A J; Trevitt, Adam J

    2013-06-01

    UV-vis photodissociation action spectroscopy is becoming increasingly prevalent because of advances in, and commercial availability of, ion trapping technologies and tunable laser sources. This study outlines in detail an instrumental arrangement, combining a commercial ion-trap mass spectrometer and tunable nanosecond pulsed laser source, for performing fully automated photodissociation action spectroscopy on gas-phase ions. The components of the instrumentation are outlined, including the optical and electronic interfacing, in addition to the control software for automating the experiment and performing online analysis of the spectra. To demonstrate the utility of this ensemble, the photodissociation action spectra of 4-chloroanilinium, 4-bromoanilinium, and 4-iodoanilinium cations are presented and discussed. Multiple photoproducts are detected in each case and the photoproduct yields are followed as a function of laser wavelength. It is shown that the wavelength-dependent partitioning of the halide loss, H loss, and NH3 loss channels can be broadly rationalized in terms of the relative carbon-halide bond dissociation energies and processes of energy redistribution. The photodissociation action spectrum of (phenyl)Ag2 (+) is compared with a literature spectrum as a further benchmark.

  6. A fast, comprehensive screening method for doping agents in urine by gas chromatography-triple quadrupole mass spectrometry.

    Science.gov (United States)

    Van Eenoo, Peter; Van Gansbeke, Wim; De Brabanter, Nik; Deventer, Koen; Delbeke, Frans T

    2011-05-27

    The use of performance enhancing drugs in sports is prohibited. For the detection of misuse of such substances gas chromatography or liquid chromatography coupled to mass spectrometry are the most frequently used detection techniques. In this work the development and validation of a fast gas chromatography tandem mass spectrometric method for the detection of a wide range of doping agents is described. The method can determine 13 endogenous steroids (the steroid profile), 19-norandrosterone, salbutamol and 11-nor-Δ9-tetrahydrocannabinol.9carboxylic acid in the applicable ranges and to detect qualitatively over 140 substances in accordance with the minimum required performance levels of the World Anti-Doping Agency in 1ml of urine. The classes of substances included in the method are anabolic steroids, β2-agonists, stimulants, narcotics, hormone antagonists and modulators and beta-blockers. Moreover, using a short capillary column and hydrogen as a carrier gas the run time of the method is less than 8min. Copyright © 2010 Elsevier B.V. All rights reserved.

  7. Detection of Chemical/Biological Agents and Stimulants using Quadrupole Ion Trap Mass Spectrometry

    International Nuclear Information System (INIS)

    Harmon, S.H.; Hart, K.J.; Vass, A.A.; Wise, M.B.; Wolf, D.A.

    1999-01-01

    Detection of Chemical/Biological Agents and Simulants A new detector for chemical and biological agents is being developed for the U. S. Army under the Chemical and Biological Mass Spectrometer Block II program. The CBMS Block II is designed to optimize detection of both chemical and biological agents through the use of direct sampling inlets[I], a multi- ported sampling valve and a turbo- based vacuum system to support chemical ionization. Unit mass resolution using air as the buffer gas[2] has been obtained using this design. Software to control the instrument and to analyze the data generated from the instrument has also been newly developed. Detection of chemical agents can be accomplished. using the CBMS Block II design via one of two inlets - a l/ I 6'' stainless steel sample line -Chemical Warfare Air (CW Air) or a ground probe with enclosed capillary currently in use by the US Army - CW Ground. The Block II design is capable of both electron ionization and chemical ionization. Ethanol is being used as the Cl reagent based on a study indicating best performance for the Biological Warfare (BW) detection task (31). Data showing good signal to noise for 500 pg of methyl salicylate injected into the CW Air inlet, 50 ng of dimethylmethylphosphonate exposed to the CW Ground probe and 5 ng of methyl stearate analyzed using the pyrolyzer inlet were presented. Biological agents are sampled using a ''bio-concentrator'' unit that is designed to concentrate particles in the low micron range. Particles are collected in the bottom of a quartz pyrolyzer tube. An automated injector is being developed to deliver approximately 2 pL of a methylating reagent, tetramethylamonium- hydroxide to 'the collected particles. Pyrolysis occurs by rapid heating to ca. 55OOC. Biological agents are then characterized by their fatty acid methyl ester profiles and by other biomarkers. A library of ETOH- Cl/ pyrolysis MS data of microorganisms used for a recently published study[3] has been

  8. Identification of Vitamin D3 Oxidation Products Using High-Resolution and Tandem Mass Spectrometry

    Science.gov (United States)

    Mahmoodani, Fatemeh; Perera, Conrad O.; Abernethy, Grant; Fedrizzi, Bruno; Greenwood, David; Chen, Hong

    2018-03-01

    In a successful fortification program, the stability of micronutrients added to the food is one of the most important factors. The added vitamin D3 is known to sometimes decline during storage of fortified milks, and oxidation through fatty acid lipoxidation could be suspected as the likely cause. Identification of vitamin D3 oxidation products (VDOPs) in natural foods is a challenge due to the low amount of their contents and their possible transformation to other compounds during analysis. The main objective of this study was to find a method to extract VDOPs in simulated whole milk powder and to identify these products using LTQ-ion trap, Q-Exactive Orbitrap and triple quadrupole mass spectrometry. The multistage mass spectrometry (MSn) spectra can help to propose plausible schemes for unknown compounds and their fragmentations. With the growth of combinatorial libraries, mass spectrometry (MS) has become an important analytical technique because of its speed of analysis, sensitivity, and accuracy. This study was focused on identifying the fragmentation rules for some VDOPs by incorporating MS data with in silico calculated MS fragmentation pathways. Diels-Alder derivatization was used to enhance the sensitivity and selectivity for the VDOPs' identification. Finally, the confirmed PTAD-derivatized target compounds were separated and analyzed using ESI(+)-UHPLC-MS/MS in multiple reaction monitoring (MRM) mode. [Figure not available: see fulltext.

  9. Identification of Vitamin D3 Oxidation Products Using High-Resolution and Tandem Mass Spectrometry.

    Science.gov (United States)

    Mahmoodani, Fatemeh; Perera, Conrad O; Abernethy, Grant; Fedrizzi, Bruno; Greenwood, David; Chen, Hong

    2018-03-19

    In a successful fortification program, the stability of micronutrients added to the food is one of the most important factors. The added vitamin D3 is known to sometimes decline during storage of fortified milks, and oxidation through fatty acid lipoxidation could be suspected as the likely cause. Identification of vitamin D3 oxidation products (VDOPs) in natural foods is a challenge due to the low amount of their contents and their possible transformation to other compounds during analysis. The main objective of this study was to find a method to extract VDOPs in simulated whole milk powder and to identify these products using LTQ-ion trap, Q-Exactive Orbitrap and triple quadrupole mass spectrometry. The multistage mass spectrometry (MS n ) spectra can help to propose plausible schemes for unknown compounds and their fragmentations. With the growth of combinatorial libraries, mass spectrometry (MS) has become an important analytical technique because of its speed of analysis, sensitivity, and accuracy. This study was focused on identifying the fragmentation rules for some VDOPs by incorporating MS data with in silico calculated MS fragmentation pathways. Diels-Alder derivatization was used to enhance the sensitivity and selectivity for the VDOPs' identification. Finally, the confirmed PTAD-derivatized target compounds were separated and analyzed using ESI(+)-UHPLC-MS/MS in multiple reaction monitoring (MRM) mode. Graphical Abstract ᅟ.

  10. Screening newborns for metabolic disorders based on targeted metabolomics using tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Hye-Ran Yoon

    2015-09-01

    Full Text Available The main purpose of newborn screening is to diagnose genetic, metabolic, and other inherited disorders, at their earliest to start treatment before the clinical manifestations become evident. Understanding and tracing the biochemical data obtained from tandem mass spectrometry is vital for early diagnosis of metabolic diseases associated with such disorders. Accordingly, it is important to focus on the entire diagnostic process, including differential and confirmatory diagnostic options, and the major factors that influence the results of biochemical analysis. Compared to regular biochemical testing, this is a complex process carried out by a medical physician specialist. It is comprised of an integrated program requiring multidisciplinary approach such as, pediatric specialist, expert scientist, clinical laboratory technician, and nutritionist. Tandem mass spectrometry is a powerful tool to improve screening of newborns for diverse metabolic diseases. It is likely to be used to analyze other treatable disorders or significantly improve existing newborn tests to allow broad scale and precise testing. This new era of various screening programs, new treatments, and the availability of detection technology will prove to be beneficial for the future generations.

  11. Techniques of tandem accelerator mass spectrometry and their applications to 14C measurements

    International Nuclear Information System (INIS)

    Nakamura, Toshio; Nakai, Nobuyuki; Furukawa, Michiaki

    1990-01-01

    A tandem accelerator mass spectrometer, named Tandetron was installed at Nagoya University in 1982 for 14 C measurement. The Tandetron spectrometer consists of a Cs sputter ion source to produce negative carbon ions, a Schenkel-type 2.2 MV tandem accelerator, an ion-beam analyzing apparatus with a charge-energy selector and mass spectrometer, and a heavy ion detector to identify and count 14 C 3+ ions from various background ions. The 14 C concentrations in pine needles, sampled at the Higashiyama Campus of Nagoya University, have been measured since 1984. The present article describes some of the measurements of 14 C in pine needles, focusing on the annual changes in the Δ 14 C value of atmospheric CO 2 , and on the effect upon 14 C concentrations for pine needles of a local 14 CO 2 emission from incineration of radioactive organic solvent wastes containing 14 C, at the Radioisotope Center in the Higashiyama Campus. The pine needles at some locations seemed to be influenced by local artificial CO 2 emission. The Δ 14 C values increased noticeably from 1956 to 1964 as a result of artificial 14 C produced in nuclear weapon tests. (N.K.)

  12. PepArML: A Meta-Search Peptide Identification Platform for Tandem Mass Spectra.

    Science.gov (United States)

    Edwards, Nathan J

    2013-12-01

    The PepArML meta-search peptide identification platform for tandem mass spectra provides a unified search interface to seven search engines; a robust cluster, grid, and cloud computing scheduler for large-scale searches; and an unsupervised, model-free, machine-learning-based result combiner, which selects the best peptide identification for each spectrum, estimates false-discovery rates, and outputs pepXML format identifications. The meta-search platform supports Mascot; Tandem with native, k-score and s-score scoring; OMSSA; MyriMatch; and InsPecT with MS-GF spectral probability scores—reformatting spectral data and constructing search configurations for each search engine on the fly. The combiner selects the best peptide identification for each spectrum based on search engine results and features that model enzymatic digestion, retention time, precursor isotope clusters, mass accuracy, and proteotypic peptide properties, requiring no prior knowledge of feature utility or weighting. The PepArML meta-search peptide identification platform often identifies two to three times more spectra than individual search engines at 10% FDR.

  13. Determination of parabens in serum by liquid chromatography-tandem mass spectrometry: Correlation with lipstick use.

    Science.gov (United States)

    Tahan, Gabriella Padovani; Santos, Nayara de Kássia Souza; Albuquerque, Ana Carolina; Martins, Isarita

    2016-08-01

    Parabens are the most widely used preservative and are considered to be relatively safe compounds. However, studies have demonstrated that they may have estrogenic activity, and there is ongoing debate regarding the safety and potential cancer risk of using products containing these compounds. In the present work, liquid chromatography-tandem mass spectrometry was applied to determine methylparaben and propylparaben concentrations in serum, and the results were correlated with lipstick application. Samples were analyzed using liquid-liquid extraction, followed by liquid chromatography-tandem mass spectrometry. The validation results demonstrated the linearity of the method over a range of 1-20 ng/mL, in addition to the method's precision and accuracy. A statistically significant difference was demonstrated between serum parabens in women who used lipstick containing these substances compared with those not using this cosmetic (p = 0.0005 and 0.0016, respectively), and a strong association was observed between serum parabens and lipstick use (Spearman correlation = 0.7202). Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Detection of various freshwater cyanobacterial toxins using ultra-performance liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Oehrle, Stuart A; Southwell, Ben; Westrick, Judy

    2010-05-01

    Several freshwater cyanobacteria species have the capability to produce toxic compounds, frequently referred to as cyanotoxins. The most prevalent of these cyanotoxins is microcystin LR. Recognizing the potential health risk, France, Italy, Poland, Australia, Canada, and Brazil have set either standards or guidelines for the amount of microcystin LR permissible in drinking water based on the World Health Organization guideline of one microg/L of microcystin LR. Recently, the United States Environmental Protection Agency has begun to evaluate the occurrence and health effects of cyanotoxins and their susceptibility to water treatment under the Safe Drinking Water Act through the Contaminant Candidate List (CCL). A recent update of the Contaminant Candidate List focuses research and data collection on the cyanotoxins microcystin LR, anatoxin-a, and cylindrospermopsin. Liquid Chromatography/Tandem-Mass Spectrometry (LC/MS/MS) is a powerful tool for the analysis of various analytes in a wide variety of matrices because of its sensitivity and selectivity. The use of smaller column media (sub 2 microm particles) was investigated to both improve the speed, sensitivity and resolution, and to quantify the CCL cyanotoxins, in a single analysis, using Ultra-Performance Liquid Chromatography (UPLC) combined with tandem mass spectrometry. Natural waters and spiked samples were analyzed to show proof-of-performance. The presented method was able to clearly resolve each of the cyanotoxins in less than eight minutes with specificity and high spike recoveries. Copyright 2009 Elsevier Ltd. All rights reserved.

  15. Confirmation of the structure of lipid A from Enterobacter agglomerans by electrospray ionization tandem mass spectrometry

    Science.gov (United States)

    Boue; Cole

    2000-03-01

    Electrospray ionization (ESI) combined with tandem mass spectrometry (MS/MS) was utilized for the structural confirmation of lipid A derived from Enterobacter agglomerans, a Gram-negative bacterium commonly found in field cotton. Previous ESI-MS studies conducted in our laboratory found that similarities exist between the fatty acid side-chains in the lipid A of E. agglomerans and that of Salmonella minnesota. It was noted that heterogeneity at the fatty acyl chain at position 3' of the diglucosamine backbone of E. agglomerans can take the form of either a myristyloxymyristyl group or, less commonly, a hydroxymyristyloxymyristyl moiety. In this work, tandem mass spectra obtained from heptaacyl and hexaacyl lipid A precursors derived from E. agglomerans and a known standard S. minnesota were compared to assist in structural elucidation. These ESI-MS/MS experiments confirmed the previously reported structure for lipid A derived from E. agglomerans. Moreover, MS/MS data indicated that the additional hydroxyl group of the 3'-position hydroxymyristyloxymyristyl moiety is present as the alpha-isomer.

  16. Determination of Sulfonamides in Chicken Muscle by Pulsed Direct Current Electrospray Ionization Tandem Mass Spectrometry.

    Science.gov (United States)

    Fu, Xian; Liang, Hengxing; Xia, Bing; Huang, Chunyan; Ji, Baocheng; Zhou, Yan

    2017-09-20

    A simple and rapid approach for the simultaneous detection of trace amounts of six sulfonamides in chicken muscle was developed using pulsed direct current electrospray ionization tandem mass spectrometry (pulsed-dc ESI-MS/MS). The pretreatment of chicken muscle samples consisted of two steps: acetonitrile extraction and n-hexane delipidation. Sulfonamides do not need to be derivatized or chromatographed prior to pulsed-dc ESI-MS/MS. The factors affecting the performance of pulsed-dc ESI-MS/MS were studied. Under optimum conditions, the quantitative performance of pulsed-dc ESI-MS/MS was validated according to European Union Decision 2002/657/EC, and the sensitivity of pulsed-dc ESI-MS/MS was 3 times higher than that of ultrahigh-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The limits of detection obtained by pulsed-dc ESI-MS/MS were in the range of 0.07-0.11 μg/kg. The proposed method was simple, rapid, and sensitive, and was successfully used for quantitation and rapid screening of sulfonamides in real chicken muscle samples.

  17. Detection of Inborn Errors of Metabolism using Tandem Mass Spectrometry among High-risk Omani Patients.

    Science.gov (United States)

    Al Riyami, Sulaiman; Al Maney, Matar; Joshi, Surendra Nath; Bayoumi, Riad

    2012-11-01

    This is a report on the types and patterns of inborn errors of metabolism (IEMs) of amino acids, organic acids and fatty acids oxidation detected by Tandem Mass Spectrometry for a period of 10 years (1998-2008) at Sultan Qaboos University Hospital (SQUH), the major centre for diagnosis and management of IEM in Oman. Tandem mass spectrometry (MS/MS) was used in the initial screening and diagnosis of IEMs in high risk neonatal and pediatric populations. Out of 1100 patients investigated, 119 were detected positive for IEM by MS/MS spectrometry. Twenty six different metabolic diseases were detected. Patients were categorized into three major groups: a) 54 with amino acids and urea cycle disorders, b) 35 with organic acid disorders, and c) 30 with fatty acid oxidation disorders. The commonest conditions encountered were maple syrup urine disease (MSUD), phenylketonuria (PKU), propionic and isovaleric acidurias, as well as HMG-CoA lyase deficiency and glutaric aciduria type II (GA-II). Most of these IEMs were over-represented in babies born to consanguineous parents, which is consistent with the recessive autosomal inheritance. This study shows that various types of IEMs, reported elsewhere, were also prevalent in Oman, but the pattern of prevalence and distribution is different. The situation, therefore, warrants the development of a nationwide screening and prevention program.

  18. Detection of Inborn Errors of Metabolism using Tandem Mass Spectrometry among High-risk Omani Patients

    Directory of Open Access Journals (Sweden)

    Sulaiman Al Riyami

    2012-11-01

    Full Text Available Objectives: This is a report on the types and patterns of inborn errors of metabolism (IEMs of amino acids, organic acids and fatty acids oxidation detected by Tandem Mass Spectrometry for a period of 10 years (1998-2008 at Sultan Qaboos University Hospital (SQUH, the major centre for diagnosis and management of IEM in Oman.Methods: Tandem mass spectrometry (MS/MS was used in the initial screening and diagnosis of IEMs in high risk neonatal and pediatric populations.Results: Out of 1100 patients investigated, 119 were detected positive for IEM by MS/MS spectrometry. Twenty six different metabolic diseases were detected. Patients were categorized into three major groups: a 54 with amino acids and urea cycle disorders, b 35 with organic acid disorders, and c 30 with fatty acid oxidation disorders. The commonest conditions encountered were maple syrup urine disease (MSUD, phenylketonuria (PKU, propionic and isovaleric acidurias, as well as HMG-CoA lyase deficiency and glutaric aciduria type II (GA-II. Most of these IEMs were over representedin babies born to consanguineous parents, which is consistent with the recessive autosomal inheritance.Conclusion: This study shows that various types of IEMs, reported elsewhere, were also prevalent in Oman, but the pattern of prevalence and distribution is different. The situation, therefore, warrants the development of a nationwide screening and prevention program.

  19. A radio frequency signal driver for quadrupole used in desktop orthogonal-injection time-of-flight mass spectrometer

    International Nuclear Information System (INIS)

    Guo, Changjuan; Jiang, Zhongyao; Xie, Chunguang; Zhu, Hui; Gao, Wei; Huang, Zhengxu; Cheng, Ping; Fu, Zhong; Zhou, Zhen

    2012-01-01

    According to the demand of home-made spectrometer, a radio frequency (RF) signal driver was developed. This RF signal driver is composed of signal generating circuit, signal amplification circuit and power output circuit, to drive the radio frequency quadrupole (RFQ). The designed RFQ is used to transfer ions generated in atmospheric pressure ion source to a home-made desktop orthogonal-injection time-of-flight mass analyzer. This signal driver is divided into low-frequency part and high-frequency part to support RFQ transferring ions of larger values (i.e., m/z=100–600) and smaller values (i.e., m/z=20–100) respectively. The low-frequency part of the RF signal driver can provide RF signals with resonance frequency of 1.43 MHz, peak to peak voltage V p–p of 0–1080 V, and the high-frequency part can provide RF signals with resonance frequency of 2.05 MHz, peak to peak voltage V p–p of 0–520 V. With the radio frequency signal driver described in this paper, ions in the range m/z 20–600 can be transmitted efficiently by RFQ. -- Highlights: ► According to the demand of home-made TOF MS, a radio frequency (RF) signal driver was developed. ► First, we calculated by the theory to determine the parameters, then based on the calculations designed the RF circuit and built it, finally tested the results. ► Found in practice, the theoretical calculations of the air core coil inductances are very close to the actual results. ► The RF circuit built is cheap, compact, stable, and easy to adjust according to the different needs of the TOF MS.

  20. Uncertainty propagation through correction methodology for the determination of rare earth elements by quadrupole based inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Raut, Narendra M.; Huang, L.-S.; Lin, K.-C.; Aggarwal, Suresh K.

    2005-01-01

    Determination of rare earth elements by quadrupole based inductively coupled plasma mass spectrometry (ICP-QMS) shows several spectroscopic overlaps from M + , MO + and MOH + ions. Especially, the spectroscopic interferences are observed from the atomic and molecular species of lighter rare earth elements including Ba during the determination of Eu, Gd and Tb. Mathematical correction methods, knowing the at.% abundances of different interfering isotopes, and the extent of formation of molecular species determined experimentally, have been used to account for various spectroscopic interferences. However, the uncertainty propagated through the mathematical correction limits its applicability. The uncertainty propagation increases with the increase in contribution from interfering species. However, for the same extent of total contribution, the overall error decreases when the interfering species are more than one. In this work, chondrite as well as a few geological reference materials containing different proportions of various rare earth elements have been used to study the contributions of different interfering species and the corresponding uncertainty in determining the concentrations of rare earth elements. A number of high abundant isotopes are proposed for determining the concentrations of various rare earth elements. The proposed isotopes are tested experimentally for determining the concentrations of different rare earth elements in two USGS reference materials AGV-1 and G-2. The interferences over those isotopes are corrected mathematically and the uncertainties propagated due to correction methodology are determined for those isotopes. The uncertainties in the determined concentrations of rare earth elements due to interference correction using the proposed isotopes are found to be comparable with those obtained by the commonly used isotopes for various rare earth elements

  1. Rapid and Accurate U-Th Dating of Ancient Carbonates using Inductively Coupled Plasma-Quadrupole Mass Spectrometry

    Science.gov (United States)

    Douville, Eric; Sallé, Eline; Frank, Norbert; Eisele, Markus; Pons-Branchu, Edwige; Ayrault, Sophie

    2010-05-01

    Here, the potential for rapid and accurate U-Th dating technique of marine aragonite skeletons (deep-sea corals, Lophelia pertusa) and secondary calcite deposits (speleothems and stalagmites) has been explored using inductively-coupled plasma-quadrupole mass spectrometry (ICP-QMS). The analytical procedure includes a largely simplified chemical separation technique for uranium (U) and thorium (Th) using UTEVA resin. The developed technique permits simultaneous quantification of uranium [238U] and thorium [232Th] concentrations and their respective isotopic composition, required for U-series disequilibrium dating. Up to 50 U-Th dates per day can be achieved through ICP-QMS with 234U and 230Th reproducibility (2sigma) of 3-4 permil and 1 percent, respectively. The high sensitivity (> 300 000 cps/ppb) together with low background (UTEVA with state-of-the-art ICP-QMS isotopic measurements that do not require a U-Th separation step now provides an extremely rapid and low-cost U-series dating technology. The level of precision is most convenient for numerous geochronological applications, such as the determination of climatic influences on ecosystem development and carbonate precipitation. As a first-example application we present ICP-QMS U-Th dates of North Atlantic deep-water coral fragments retrieved in the southeastern Porcupine Seabight (MD01-2463G, Mound Thérèse), indicating a purely interglacial growth of deep-water corals on so-called carbonate mounds over several climate cycles.

  2. Effect of heating strategies on whey protein denaturation--Revisited by liquid chromatography quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Akkerman, M; Rauh, V M; Christensen, M; Johansen, L B; Hammershøj, M; Larsen, L B

    2016-01-01

    Previous standards in the area of effect of heat treatment processes on milk protein denaturation were based primarily on laboratory-scale analysis and determination of denaturation degrees by, for example, electrophoresis. In this study, whey protein denaturation was revisited by pilot-scale heating strategies and liquid chromatography quadrupole time-of-flight mass spectrometer (LC/MC Q-TOF) analysis. Skim milk was heat treated by the use of 3 heating strategies, namely plate heat exchanger (PHE), tubular heat exchanger (THE), and direct steam injection (DSI), under various heating temperatures (T) and holding times. The effect of heating strategy on the degree of denaturation of β-lactoglobulin and α-lactalbumin was determined using LC/MC Q-TOF of pH 4.5-soluble whey proteins. Furthermore, effect of heating strategy on the rennet-induced coagulation properties was studied by oscillatory rheometry. In addition, rennet-induced coagulation of heat-treated micellar casein concentrate subjected to PHE was studied. For skim milk, the whey protein denaturation increased significantly as T and holding time increased, regardless of heating method. High denaturation degrees were obtained for T >100°C using PHE and THE, whereas DSI resulted in significantly lower denaturation degrees, compared with PHE and THE. Rennet coagulation properties were impaired by increased T and holding time regardless of heating method, although DSI resulted in less impairment compared with PHE and THE. No significant difference was found between THE and PHE for effect on rennet coagulation time, whereas the curd firming rate was significantly larger for THE compared with PHE. Micellar casein concentrate possessed improved rennet coagulation properties compared with skim milk receiving equal heat treatment. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  3. Determination of pesticide residues in animal origin baby foods by gas chromatography coupled with triple quadrupole mass spectrometry.

    Science.gov (United States)

    Amendola, Graziella; Pelosi, Patrizia; Attard Barbini, Danilo

    2015-01-01

    A simple, fast and multiresidue method for the determination of pesticide residues in baby foods of animal origin has been developed in order to check the compliance with the Maximum Residue Levels (MRLs) set at a general value of 0.01 mg/kg by Commission Directive 2006/125/EC for infant foods. The main classes of organochlorine, organophosphorus and pyrethroid compounds have been considered, which are mainly fat soluble pesticides. The analytical procedure consists in the extraction of baby food samples by acetonitrile (ACN) followed by a clean up using C18 solid-phase extraction column eluted with ACN. The compounds were determined by gas chromatography-triple quadrupole mass spectrometry equipped with a Programmed Temperature Vaporizer (PTV) injection and a backflush system. In order to compensate for matrix effects PTV and matrix matched standard calibrations have been used. The method has been fully validated for 57 pesticides according to the Document SANCO/12571/2013. Accuracy and precision (repeatability) have been studied by recoveries at two spiking levels, the Limit of Quantitation (LOQ) (0.003-0.008 mg/kg) and 10 time greater (0.03-0.08 mg/kg), and the results were in the acceptable range of 70-120% with Relative Standards Deviations (RSD) ≤20%. Selectivity, linearity, LOQ and uncertainty of measurement were also determined for all the compounds. The method has been also applied for the analysis of 18 baby food animal origin samples, bought form the local market in Rome (Italy), and no pesticide in the scope of the method has been found above the MRL or the LOQ.

  4. Multiple heart-cutting two dimensional liquid chromatography quadrupole time-of-flight mass spectrometry of pyrrolizidine alkaloids.

    Science.gov (United States)

    van de Schans, Milou G M; Blokland, Marco H; Zoontjes, Paul W; Mulder, Patrick P J; Nielen, Michel W F

    2017-06-23

    Pyrrolizidine alkaloids (PAs) and their and the corresponding N-oxides (PAs-ox) are genotoxic plant metabolites which can be present as unwanted contaminants in food products of herbal origin like tea and food supplements. PAs and PAs-ox come in a wide variety of molecular structures including many structural isomers. For toxicity assessment it is important to determine the composition of a sample and to resolve all isomeric PAs and PAs-ox, which is currently not possible in one liquid or gas chromatographic (LC or GC) run. In this study an online two dimensional liquid chromatography quadrupole time-of-flight mass spectrometry (2D-LC QToF-MS) method was developed to resolve isomeric PAs and PAs-ox. After comprehensive column and mobile phase selection a polar endcapped C 18 column was used at pH 3 in the first dimension, and a cross-linked C 18 column at pH 10 in the second dimension. Injection solvents, column IDs, flow rates and temperatures were carefully optimized. The method with column selection valve switching described in this study was able to resolve and visualize 20 individual PAs/PAs-ox (6 sets of isomers) in one 2D-LC QToF-MS run. Moreover, it was shown that all isomeric PAs/PAs-ox could be unambiguously annotated. The method was shown to be applicable for the determination and quantification of isomeric PAs/PAs-ox in plant extracts and could be easily extended to include other PAs and PAs-ox. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Determination of clarithromycin in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Jiang, Yao; Wang, Jiang; Li, Hao; Wang, Yingwu; Gu, Jingkai

    2007-03-12

    A rapid and sensitive method has been developed for the determination of clarithromycin in human plasma with liquid chromatography-tandem mass spectrometry. Clarithromycin and the internal standard, telmisartan were precipitated from the matrix (50 microl) with 200 microl acetonitrile and separated by HPLC using formic acid:10 mM ammonium acetate:methanol (1:99:400, v/v/v) as the mobile phase. The assay based on detection by electrospray positive ionization mass spectrometry in the multiple-reaction monitoring mode was finished within 2.4 min. Linearity was over the concentration range 10-5000 ng/ml with a limit of detection of 0.50 ng/ml. Intra- and inter-day precision measured as relative standard deviation were bioequivalence study of two tablet formulations of clarithromycin.

  6. Liquid Chromatography-Tandem Mass Spectrometry: An Emerging Technology in the Toxicology Laboratory.

    Science.gov (United States)

    Zhang, Yan Victoria; Wei, Bin; Zhu, Yu; Zhang, Yanhua; Bluth, Martin H

    2016-12-01

    In the last decade, liquid chromatography-tandem mass spectrometry (LC-MS/MS) has seen enormous growth in routine toxicology laboratories. LC-MS/MS offers significant advantages over other traditional testing, such as immunoassay and gas chromatography-mass spectrometry methodologies. Major strengths of LC-MS/MS include improvement in specificity, flexibility, and sample throughput when compared with other technologies. Here, the basic principles of LC-MS/MS technology are reviewed, followed by advantages and disadvantages of this technology compared with other traditional techniques. In addition, toxicology applications of LC-MS/MS for simultaneous detection of large panels of analytes are presented. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Enhancing Accuracy in Molecular Weight Determination of Highly Heterogeneously Glycosylated Proteins by Native Tandem Mass Spectrometry.

    Science.gov (United States)

    Wang, Guanbo; de Jong, Rob N; van den Bremer, Ewald T J; Parren, Paul W H I; Heck, Albert J R

    2017-05-02

    The determination of molecular weights (MWs) of heavily glycosylated proteins is seriously hampered by the physicochemical characteristics and heterogeneity of the attached carbohydrates. Glycosylation impacts protein migration during sodium dodecyl sulfate (SDS)-polyacrylamide gel electrophoresis (PAGE) and size-exclusion chromatography (SEC) analysis. Standard electrospray ionization (ESI)-mass spectrometry does not provide a direct solution as this approach is hindered by extensive interference of ion signals caused by closely spaced charge states of broadly distributed glycoforms. Here, we introduce a native tandem MS-based approach, enabling charge-state resolution and charge assignment of protein ions including those that escape mass analysis under standard MS conditions. Using this method, we determined the MW of two model glycoproteins, the extra-cellular domains of the highly and heterogeneously glycosylated proteins CD38 and epidermal growth factor receptor (EGFR), as well as the overall MW and binding stoichiometries of these proteins in complex with a specific antibody.

  8. PECAN: library-free peptide detection for data-independent acquisition tandem mass spectrometry data

    Energy Technology Data Exchange (ETDEWEB)

    Ting, Ying S.; Egertson, Jarrett D.; Bollinger, James G.; Searle, Brian C.; Payne, Samuel H.; Noble, William Stafford; MacCoss, Michael J.

    2017-08-07

    Data-independent acquisition (DIA) is an emerging mass spectrometry (MS)-based technique for unbiased and reproducible measurement of protein mixtures. DIA tandem mass spectrometry spectra are often highly multiplexed, containing product ions from multiple cofragmenting precursors. Detecting peptides directly from DIA data is therefore challenging; most DIA data analyses require spectral libraries. Here we present PECECAN (http://pecan.maccosslab.org), a library-free, peptide-centric tool that robustly and accurately detects peptides directly from DIA data. PECECAN reports evidence of detection based on product ion scoring, which enables detection of low-abundance analytes with poor precursor ion signal. We demonstrate the chromatographic peak picking accuracy and peptide detection capability of PECECAN, and we further validate its detection with data-dependent acquisition and targeted analyses. Lastly, we used PECECAN to build a plasma proteome library from DIA data and to query known sequence variants.

  9. Retarding potential and induction charge detectors in tandem for measuring the charge and mass of nanodroplets

    International Nuclear Information System (INIS)

    Gamero-Castano, Manuel

    2009-01-01

    The determination of the mass of a nanoparticle via time-of-flight typically requires a direct measurement of its charge. This can be done with a differential retarding potential analyzer and an induction charge detector operating in tandem. The spectrometer described in this article selects a particle with a specified retarding potential from a beam and directs it to an induction charge detector where both its velocity and charge are measured. The retarding potential, velocity, and charge also yield the particle's mass. The particle is analyzed without the need to collect it, and therefore can be employed in a subsequent experiment. The high charge sensitivity of the induction charge detector and the capability for working at low retarding potentials make the characterization of electrosprayed nanodroplets possible for the first time.

  10. Evaluation of the performance of a tandem mass spectral library with mass spectral data extracted from literature.

    Science.gov (United States)

    Würtinger, Philipp; Oberacher, Herbert

    2012-01-01

    MSforID represents a database of tandem mass spectral data obtained from (quasi-)molecular ions produced by atmospheric pressure ionization methods. At the current stage of development the library contains 12 122 spectra of 1208 small (bio-)organic molecules. The present work was aimed to evaluate the performance of the MSforID library in terms of accuracy and transferability with a collection of fragment ion mass spectra from various compounds acquired on multiple instruments. A literature survey was conducted to collect the set of sample spectra. A total number of 554 spectra covering 291 compounds were extracted from 109 publications. The majority of spectra originated from publications on applications of LC/MS/MS in drug monitoring, pharmacokinetics, environmental analysis, forensic analysis as well as food analysis. Almost all types of tandem mass spectrometric instruments distributed by the five most important instrument vendors were included in the study. The overall sensitivity of library search was found to be 96.4%, which clearly proves that the MSforID library can successfully handle data from a huge variety of mass spectrometric instruments to allow accurate compound identification. Only for spectra containing three or more fragment ions, however, the rate of classified matches (= matches with a relative average match probability (ramp) score > 40.0) was 95%. Ambiguous or unclassified results were mainly obtained for searches with single precursor-to-fragment ion transitions due to the insufficient specificity of such a low amount of structural information to unequivocally define a single compound. Copyright © 2011 John Wiley & Sons, Ltd.

  11. Characterization of Disulfide-Linked Peptides Using Tandem Mass Spectrometry Coupled with Automated Data Analysis Software

    Science.gov (United States)

    Liang, Zhidan; McGuinness, Kenneth N.; Crespo, Alejandro; Zhong, Wendy

    2018-01-01

    Disulfide bond formation is critical for maintaining structure stability and function of many peptides and proteins. Mass spectrometry has become an important tool for the elucidation of molecular connectivity. However, the interpretation of the tandem mass spectral data of disulfide-linked peptides has been a major challenge due to the lack of appropriate tools. Developing proper data analysis software is essential to quickly characterize disulfide-linked peptides. A thorough and in-depth understanding of how disulfide-linked peptides fragment in mass spectrometer is a key in developing software to interpret the tandem mass spectra of these peptides. Two model peptides with inter- and intra-chain disulfide linkages were used to study fragmentation behavior in both collisional-activated dissociation (CAD) and electron-based dissociation (ExD) experiments. Fragments generated from CAD and ExD can be categorized into three major types, which result from different S-S and C-S bond cleavage patterns. DiSulFinder is a computer algorithm that was newly developed based on the fragmentation observed in these peptides. The software is vendor neutral and capable of quickly and accurately identifying a variety of fragments generated from disulfide-linked peptides. DiSulFinder identifies peptide backbone fragments with S-S and C-S bond cleavages and, more importantly, can also identify fragments with the S-S bond still intact to aid disulfide linkage determination. With the assistance of this software, more comprehensive disulfide connectivity characterization can be achieved. [Figure not available: see fulltext.

  12. Miniaturized GC/MS instrumentation for in situ measurements: micro gas chromatography coupled with miniature quadrupole array and paul ion trap mass spectrometers

    Science.gov (United States)

    Holland, P.; Chutjian, A.; Darrach, M.; Orient, O.

    2002-01-01

    Miniaturized chemical instrumentation is needed for in situ measurements in planetary exploration and other spaceflight applications where factors such as reduction in payload requirements and enhanced robustness are important. In response to this need, we are 'continuing to develop miniaturized GC/MS instrumentation which combines chemical separations by gas chromatography (GC) with mass spectrometry (MS) to provide positive identification of chemical compounds in complex mixtures of gases, such as those found in the International Space Station's cabin atmosphere. Our design approach utilizes micro gas chromatography components coupled with either a miniature quadrupole mass spectrometer array (QMSA) or compact, high-resolution Paul ion trap.

  13. Suspected-target pesticide screening using gas chromatography-quadrupole time-of-flight mass spectrometry with high resolution deconvolution and retention index/mass spectrum library.

    Science.gov (United States)

    Zhang, Fang; Wang, Haoyang; Zhang, Li; Zhang, Jing; Fan, Ruojing; Yu, Chongtian; Wang, Wenwen; Guo, Yinlong

    2014-10-01

    A strategy for suspected-target screening of pesticide residues in complicated matrices was exploited using gas chromatography in combination with hybrid quadrupole time-of-flight mass spectrometry (GC-QTOF MS). The screening workflow followed three key steps of, initial detection, preliminary identification, and final confirmation. The initial detection of components in a matrix was done by a high resolution mass spectrum deconvolution; the preliminary identification of suspected pesticides was based on a special retention index/mass spectrum (RI/MS) library that contained both the first-stage mass spectra (MS(1) spectra) and retention indices; and the final confirmation was accomplished by accurate mass measurements of representative ions with their response ratios from the MS(1) spectra or representative product ions from the second-stage mass spectra (MS(2) spectra). To evaluate the applicability of the workflow in real samples, three matrices of apple, spinach, and scallion, each spiked with 165 test pesticides in a set of concentrations, were selected as the models. The results showed that the use of high-resolution TOF enabled effective extractions of spectra from noisy chromatograms, which was based on a narrow mass window (5 mDa) and suspected-target compounds identified by the similarity match of deconvoluted full mass spectra and filtering of linear RIs. On average, over 74% of pesticides at 50 ng/mL could be identified using deconvolution and the RI/MS library. Over 80% of pesticides at 5 ng/mL or lower concentrations could be confirmed in each matrix using at least two representative ions with their response ratios from the MS(1) spectra. In addition, the application of product ion spectra was capable of confirming suspected pesticides with specificity for some pesticides in complicated matrices. In conclusion, GC-QTOF MS combined with the RI/MS library seems to be one of the most efficient tools for the analysis of suspected-target pesticide residues

  14. Mass Spectral Studies of 1-(2-Chloroethoxy)-2-[(2-chloroethyl)thio] Ethane and Related Compounds Using Gas ChromatographyMass Spectrometry and Gas ChromatographyTriple-Quadrupole Mass Spectrometry

    Science.gov (United States)

    2016-02-01

    characteristic ions. 15. SUBJECT TERMS Sulfur mustard Degradation product Tandem mass spectrometry (MS-MS) Fragmentation Gas chromatography (GC...MacIver, B.K.; Rohrbaugh, D.K.; Yang, Y.C. Thermal Degradation of Bis (2-Chloroethyl) Sulfide ( Mustard Gas ). Phosphorus Sulfur Silicon Relat. Elem...MASS SPECTRAL STUDIES OF 1-(2-CHLOROETHOXY)-2-[(2-CHLOROETHYL)THIO] ETHANE AND RELATED COMPOUNDS USING GAS

  15. Quantitation of α-Lactalbumin by Liquid Chromatography Tandem Mass Spectrometry in Medicinal Adjuvant Lactose

    Directory of Open Access Journals (Sweden)

    Rui Yan

    2014-01-01

    Full Text Available Lactose is a widely used pharmaceutical excipient, sometimes irreplaceable. Traces of residual proteins left during production of lactose are potential allergen to body. The present paper describes a sensitive and specific LC-MS method for the determination of α-lactalbumin (α-La in lactose samples. Chromatographic separation was performed on an Acquity UPLC BEH300 C18 column (2.1×150 mm, 1.7 μm with an isocratic mobile phase consisting of water containing 0.1% TFA and acetonitrile containing 0.1% TFA (80 : 20, v/v. Mass spectrometric detection was achieved by a triple-quadrupole mass spectrometer equipped with an ESI interface operating in positive ionization mode. Quantitation was performed using selected ion monitoring of m/z 2364 for α-La. The calibration curve was linear from 0.2 to 10 µg/mL. The intra- and interday precisions were less than 7.6% and the accuracy ranged from 96.4 to 104.5%. The limit of quantification (LOQ was 0.15 µg/mL and the limit of detection (LOD was 0.05 µg/mL. This method was then successfully applied to investigate 6 different lactose samples. The application can provide technical preparation for the development of specification of lactose.

  16. Diagnosing lysosomal storage diseases in a Brazilian non-newborn population by tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Guilherme Dotto Brand

    2013-11-01

    Full Text Available OBJECTIVES: High-throughput mass spectrometry methods have been developed to screen newborns for lysosomal storage disorders, allowing the implementation of newborn screening pilot studies in North America and Europe. It is currently feasible to diagnose Pompe, Fabry, Gaucher, Krabbe, and Niemann-Pick A/B diseases, as well as mucopolysaccharidosis I, by tandem mass spectrometry in dried blood spots, which offers considerable technical advantages compared with standard methodologies. We aimed to investigate whether the mass spectrometry methodology for lysosomal storage disease screening, originally developed for newborns, can also discriminate between affected patients and controls of various ages. METHODS: A total of 205 control individuals were grouped according to age and subjected to mass spectrometry quantification of lysosomal α-glucosidase, β-glucocerebrosidase, α-galactosidase, acid sphingomyelinase, galactocerebrosidase, and α−L-iduronidase activities. Additionally, 13 affected patients were analyzed. RESULTS: The median activities for each enzyme and each age group were determined. Enzyme activities were significantly lower in individuals aged older than 18 years compared with those in newborns. Affected patients presented enzymatic activities corresponding to less than 20% of the age-matched controls. CONCLUSIONS: Our data indicate that the mass spectrometry methodology can be used for the screening of lysosomal storage diseases in non-newborn patients. However, for some diseases, such as Fabry and mucopolysaccharidosis I, a combination of biochemical and clinical data may be necessary to achieve accurate diagnoses.

  17. Gas-Phase Fragmentation Behavior of Oxidized Prenyl Peptides by CID and ETD Tandem Mass Spectrometry

    Science.gov (United States)

    Bhawal, Ruchika P.; Shahinuzzaman, A. D. A.; Chowdhury, Saiful M.

    2017-04-01

    Farnesylation and geranylgeranylation are the two types of prenyl modification of proteins. Prenylated peptides are highly hydrophobic and their abundances in biological samples are low. In this report, we studied the oxidized prenylated peptides by electrospray ionization mass spectrometry and identified them by collision-induced dissociation (CID) and electron-transfer dissociation (ETD) tandem mass spectrometry. Modified prenyl peptides were generated utilizing strong and low strength oxidizing agents to selectively oxidize and epoxidize cysteine sulfur and prenyl side chain. We selected three peptides with prenyl motifs and synthesized their prenylated versions. The detailed characteristic fragmentations of oxidized and epoxidized farnesylated and geranylgeranylated peptides were studied side by side with two popular fragmentation techniques. CID and ETD mass spectrometry clearly distinguished the modified version of these peptides. ETD mass spectrometry provided sequence information of the highly labile modified prenyl peptides and showed different characteristic fragmentations compared with CID. A detailed fragmentation of modified geranylgeranylated peptides was compared by CID and ETD mass spectrometry for the first time.

  18. Advanced Laser Architecture for Two-Step Laser Tandem Mass Spectrometer

    Science.gov (United States)

    Fahey, Molly E.; Li, Steven X.; Yu, Anthony W.; Getty, Stephanie A.

    2016-01-01

    Future astrobiology missions will focus on planets with significant astrochemical or potential astrobiological features, such as small, primitive bodies and the icy moons of the outer planets that may host diverse organic compounds. These missions require advanced instrument techniques to fully and unambiguously characterize the composition of surface and dust materials. Laser desorptionionization mass spectrometry (LDMS) is an emerging instrument technology for in situ mass analysis of non-volatile sample composition. A recent Goddard LDMS advancement is the two-step laser tandem mass spectrometer (L2MS) instrument to address the need for future flight instrumentation to deconvolve complex organic signatures. The L2MS prototype uses a resonance enhanced multi-photon laser ionization mechanism to selectively detect aromatic species from a more complex sample. By neglecting the aliphatic and inorganic mineral signatures in the two-step mass spectrum, the L2MS approach can provide both mass assignments and clues to structural information for an in situ investigation of non-volatile sample composition. In this paper we will describe our development effort on a new laser architecture that is based on the previously flown Lunar Orbiter Laser Altimeter (LOLA) laser transmitter for the L2MS instrument. The laser provides two discrete midinfrared wavelengths (2.8 m and 3.4 m) using monolithic optical parametric oscillators and ultraviolet (UV) wavelength (266 nm) on a single laser bench with a straightforward development path toward flight readiness.

  19. [Values of tandem mass spectrometry in etiologic diagnosis of cerebral developmental retardation].

    Science.gov (United States)

    Zhang, Jian-ming; Gu, Xue-fan; Shao, Xin-hua; Song, Xiao-qing; Han, Lian-shu; Ye, Jun; Qiu, Wen-juan; Gao, Xiao-lan; Wang, Yu; Wang, Mei-xian

    2007-12-01

    To investigate the values of tandem mass spectrometry (MS/MS) in etiologic diagnosis and understanding therapeutic effect in cerebral developmental retardation, and to help patients in early diagnosis, treatment and favorable prognosis. One hundred and fifty-eight childhood patients with brain heteroplasia were tested from July 2004 to October 2006. The blood was collected on filter paper, punched and extracted into methanol solution with stable isotope labeled internal standards, then derivatized with butanolic-HCl. After preparation, the samples were analysed by tandem mass spectrometry. Eleven MS/MS-positive patients were further analyzed based on gas chromatography/mass spectrometry (GC/MS) analysis of urine, clinical course, and treatment outcome. Eleven of 158 patients (7.0%) with inborn metabolic error were confirmed, including five with methylmalonic acidemia, two with propionic acidemia, one with ornithine transcarbamylase deficiency, one with maple syrup urine disease, one with phenylketonuria, and one with biotinidase deficiency. Among them, five were male, six were female, aged from 4 days to 21 months. The clinical manifestations were diverse, including mental developmental retardation or degradation (11 cases), convulsion (5 cases), coma (4 cases), vomiting (4 cases), malnutrition (4 cases), lethargy (3 cases), repeated infection (3 cases), hypotonia (2 cases), etc. Laboratory findings showed metabolic acidosis, hyperammonemia, hyperlactacidemia, anemia, etc. MRI findings of the brain showed cerebral atrophy, a pattern of bilateral T(2)W high signal intensity or/and T(1)W low signal intensity in cerebral white matter and multiple encephalomalacia or vesicular change, ect. In methylmalonic acidemia patients, the early onset with severe acidosis and coma have had a poor prognosis. Improvement was observed in 8 cases after treatment with vitamin B(12), L-carnitine, special milk, low-protein diet or biotin, etc. However 3 MMA patients died. MS/MS was

  20. [Present status of expanded newborn screening project for inborn errors of metabolism by tandem mass spectrometry].

    Science.gov (United States)

    Kuhara, Tomiko

    2014-01-01

    In Japan, screening for six diseases including four inborn errors of metabolism has been performed since 1977 for all neonates to prevent severe mental handicaps or death. A rapid screening procedure for analysis of several amino acids and acylcarnitines in blood spots by tandem mass spectrometry was developed by Millington DS et al. in the early 1990s. Although it is called expanded (or extended) newborn screening, the procedure is insufficiently sensitive to or specific for several diseases. Screening for all diseases that can be screened using this procedure is suggested to be cost-ineffective. Many European countries target only two diseases: medium-chain acyl-CoA dehydrogenase deficiency and phenylketonuria; their prevalence in Caucasian populations is very high, but some countries target more than twenty diseases and others an intermediate number. A pilot study targeting 22 diseases suggests that the combined incidence is one per 9,000 (0.01%) in Japan. This primary screening requires secondary screening to confirm the disease using urine, and either organic acids with solvent extraction or metabolome without fractionation are analyzed by gas chromatography-mass spectrometry. There is no need for primary or secondary screening tests to be performed at the same laboratory because the skills required are quite different. Understanding of the methodological problems of tandem mass screening and amelioration of variation and false positivity rate of this screening method among laboratories are critical to the success of the screening system in Japan. GC/MS-based urine metabolomics is expected to become one of the primary screening methodologies for neonates/infants who are already ill.

  1. Quantitation of isobaric phosphatidylcholine species in human plasma using a hybrid quadrupole linear ion-trap mass spectrometer

    Czech Academy of Sciences Publication Activity Database

    Žáček, Petr; Bukowski, M.; Rosenberger, T. A.; Picklo, M.

    2016-01-01

    Roč. 57, č. 12 (2016), s. 2225-2234 ISSN 0022-2275 Institutional support: RVO:61388963 Keywords : shotgun lipidomics * triple quadrupole/ion-trap * human blood plasma * phosphatidylcholines Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 4.810, year: 2016 http://www.jlr.org/content/57/12/2225.full

  2. Quantitative analysis of flavanones from citrus fruits by using mesoporous molecular sieve-based miniaturized solid phase extraction coupled to ultrahigh-performance liquid chromatography and quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Cao, Wan; Ye, Li-Hong; Cao, Jun; Xu, Jing-Jing; Peng, Li-Qing; Zhu, Qiong-Yao; Zhang, Qian-Yun; Hu, Shuai-Shuai

    2015-08-07

    An analytical procedure based on miniaturized solid phase extraction (SPE) and ultrahigh-performance liquid chromatography coupled with quadrupole time-of-flight tandem mass spectrometry was developed and validated for determination of six flavanones in Citrus fruits. The mesoporous molecular sieve SBA-15 as a solid sorbent was characterised by Fourier transform-infrared spectroscopy and scanning electron microscopy. Additionally, compared with reported extraction techniques, the mesoporous SBA-15 based SPE method possessed the advantages of shorter analysis time and higher sensitivity. Furthermore, considering the different nature of the tested compounds, all of the parameters, including the SBA-15 amount, solution pH, elution solvent, and the sorbent type, were investigated in detail. Under the optimum condition, the instrumental detection and quantitation limits calculated were less than 4.26 and 14.29ngmL(-1), respectively. The recoveries obtained for all the analytes were ranging from 89.22% to 103.46%. The experimental results suggested that SBA-15 was a promising material for the purification and enrichment of target flavanones from complex citrus fruit samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Cyclodextrin-based miniaturized solid phase extraction for biopesticides analysis in water and vegetable juices samples analyzed by ultra-high-performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Peng, Li-Qing; Ye, Li-Hong; Cao, Jun; Chang, Yan-Xu; Li, Qin; An, Mingrui; Tan, Zhijing; Xu, Jing-Jing

    2017-07-01

    A cyclodextrin-based miniaturized solid-phase extraction was developed to extract biopesticides from water and vegetable juices. The analytes were detected by ultra-high-performance liquid chromatography coupled with quadrupole time-of-flight tandem mass spectrometry. In the solid-phase extraction (SPE) procedure, the liquid sample solution is passed through a packed column filled with 40mg of HP-β-CD, and then the target analytes are absorbed and finally eluted with methanol-acetic acid (90:10, v/v) into a collection tube. The limits of quantification ranged from 3.73 to 16.51ng/mL for a water matrix, from 2.62 to 13.23ng/mL for an orange juice matrix and from 1.76 to 10.35ng/mL for a tomato juice matrix, respectively. The average recovery values were in the range of 88.3-95.9% for the spiked samples. The established methodology was successfully applied to analyze sanguinarine, berberine, rotenone and osthole in water, orange juice and tomato juice. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Simultaneous determination of 17 disperse dyes in textile by ultra-high performance supercritical fluid chromatography combined with tandem mass spectrometry.

    Science.gov (United States)

    Zhou, Ying; Du, Zhenxia; Zhang, Yun

    2014-09-01

    A simple, highly sensitive and fast procedure for the control of 17 allergenic and prohibited disperse dyes in textile products was optimized. The method was based on ultrasound assisted extraction of textile samples with 10 mL of methanol under controlled conditions (30 min, 70°C). The extracts were analyzed by the ultra-high performance supercritical fluid chromatography (UHPSFC) system coupled with triple quadrupole tandem mass spectrometry (MS/MS). Four stationary phases (BEH, BEH 2-ethyl-pyridine, HSS C18 SB and CSH fluorophenyl) were screened as well as analytical conditions (modifier percentage, backpressure and column temperature) were investigated to improve the separation. All 17 disperse dyes were simultaneously separated and determined by UHPSFC-MS/MS in 5 min. The dyes were monitored via the ESI(+) ionization method and quantified by 3-channel multiple reaction monitoring (MRM). The calibrations were performed and good linear relationship (R≥0.99) was observed within the concentration range of 2-50 μg mL(-1). Satisfactory recoveries (70.55-103.03%) of all the disperse dyes spiked with standards at different levels were demonstrated. This is the first report on the simultaneous analysis of disperse dyes using UHPSFC-MS/MS. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Simultaneous analysis of eight phenolic environmental estrogens in blood using dispersive micro-solid-phase extraction combined with ultra fast liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Zhao, Yong-Gang; Chen, Xiao-Hong; Pan, Sheng-Dong; Zhu, Hao; Shen, Hao-Yu; Jin, Mi-Cong

    2013-10-15

    A novel, simple and sensitive method was developed for the simultaneous determination of eight phenolic environmental estrogens in blood by using the dispersive micro-solid-phase extraction (d-µ-SPE) procedure combined with ultra-fast liquid chromatography-tandem quadrupole mass spectrometry (UFLC-MS/MS). The excellent nanomaterials tetraethylenepentamine-functionalized magnetic polymer was used as an adsorbent, and the main factors affecting the extraction efficiency were investigated in detail. All target compounds showed good linearities in the tested range with correlation coefficients (r) higher than 0.999. The mean recoveries were in the range of 85.0-105.0%. The intra-day and inter-day relative standard deviations (RSDs) were lower than 4.9% and 5.2%, respectively. The limits of quantification for the eight phenolic environmental estrogens were between 0.075 and 0.42 µg L(-1). The developed method can be applied to the routine analyses for the determination of the eight phenolic environmental estrogens in blood samples. Crown Copyright © 2013 Published by Elsevier B.V. All rights reserved.

  6. Simultaneous determination of amino acids and neurotransmitters in plasma samples from schizophrenic patients by hydrophilic interaction liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Domingues, Diego Soares; Crevelin, Eduardo José; de Moraes, Luiz Alberto Beraldo; Cecilio Hallak, Jaime Eduardo; de Souza Crippa, José Alexandre; Costa Queiroz, Maria Eugênia

    2015-03-01

    A sensitive, reproducible, and rapid method was developed for the simultaneous determination of underivatized amino acids (aspartate, serine, glycine, alanine, methionine, leucine, tyrosine, and tryptophan) and neurotransmitters (glutamate and γ-aminobutyric acid) in plasma samples using hydrophilic interaction liquid chromatography coupled to triple quadrupole tandem mass spectrometry. The plasma concentrations of amino acids and neurotransmitters obtained from 35 schizophrenic patients in treatment with clozapine (27 patients) and olanzapine (eight patients) were compared with those obtained from 38 healthy volunteers to monitor the effectiveness of treatment. The chromatographic conditions separated ten target compounds within 3 min. This method presented linear ranges that varied from (lower limit of quantification: 9.7-13.3 nmol/mL) to (upper limit of quantification: 19.4-800 nmol/mL), intra- and interassay precision with coefficients of variation lower than 10%, and relative standard error values of the accuracy ranged from -2.1 to 9.9%. The proposed method appropriately determines amino acids and neurotransmitters in plasma from schizophrenic patients. Compared with the control group (healthy volunteers), the plasma levels of methionine in schizophrenic patients treated with olanzapine are statistically significantly higher. Moreover, schizophrenic patients treated with clozapine tend to have increased plasma levels of glutamate. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Development of a multi-residue method for fast screening and confirmation of 20 prohibited veterinary drugs in feedstuffs by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Zhang, Gui-Jun; Fang, Bing-Hu; Liu, Ya-Hong; Wang, Xu-Feng; Xu, Li-Xiao; Zhang, Ya-Ping; He, Li-Min

    2013-10-01

    A simple multiresidue method was developed for detecting and quantifying twenty analytes from 5 classes of prohibited veterinary drugs (β-agonists (9), anabolic hormones (4), quinoxalines (4), tranquilizers (1), cyproheptadine, and clonidine in animal feeds using a QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) approach. Feed samples were extracted by ultrasonic-assisted extraction with a mixture of methanol-acetonitrile (50:50, v/v), followed by a cleanup using a dispersive solid-phase extraction with PSA (primary secondary amine). Target compounds were separated and determined by a liquid chromatography tandem quadrupole mass spectrometer operating in positive electrospray ionization mode, using multiple reaction monitoring (MRM). The recoveries of these compounds were between 56.7% and 103% at three spiked levels. The repeatability was lower than 10%, whereas reproducibility was no more than 15% except for nandrolone (17% at 10μgkg(-1)) and diazepam (19% at 10μgkg(-1)). Decision limits (CCαs) and detection capabilities (CCβs) ranged from 0.42 to 5.74μgkg(-1) and 5.70-9.81μgkg(-1), respectively. The method was successfully applied to screening of real samples obtained from local feed markets and confirmation of the suspected target analytes. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Simultaneous determination of fumonisins B1, B2 and B3 contaminants in maize by ultra high-performance liquid chromatography tandem mass spectrometry

    International Nuclear Information System (INIS)

    Ren Yiping; Zhang Yu; Han Shiyun; Han Zheng; Wu Yongning

    2011-01-01

    The present work developed an analytical method for simultaneous determination of fumonisins B 1 , B 2 and B 3 residues in maize by ultra high-performance liquid chromatography combined with electrospray ionization triple quadrupole tandem mass spectrometry (UHPLC-MS/MS) under the multiple reaction monitoring (MRM) mode, and especially focused on the optimization of extraction, clean-up, UHPLC separation and MS/MS parameters. The method involves addition of fumonisins isotope internal standards, extraction with a mixture of acetonitrile and water and clean-up with solid-phase extraction (SPE) cartridges before UHPLC-MS/MS analysis. A single-laboratory method validation was conducted by testing three different spiking levels for repeatability and recovery according to International Union of Pure and Applied Chemistry (IUPAC) guidelines. The LOQ of FB 1 , FB 2 and FB 3 were 1.50, 1.65 and 0.4 μg kg -1 , respectively, which were lower than the criteria of EU, USA and other countries regarding minimum residue limits of fumonisins in foods including baby foods and feedstuffs. Recoveries of three fumonisins ranged from 80.9% to 97.0% with RSD values of 2.4-11.1%.The advantages of this method include simple pretreatment, rapid determination and high sensitivity, and it fulfills the requirements for food analysis with respect to minimum residue limits of fumonisins in various countries.

  9. Determination of per- and polyfluorinated substances in airborne particulate matter by microwave-assisted extraction and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Beser, Maria Isabel; Pardo, Olga; Beltrán, Joaquim; Yusà, Vicent

    2011-07-29

    A sensitive and confirmatory analytical method has been developed for the determination of 12 ionic per- and polyfluorinated alkyl substances (PFAS) in fine airborne particulate matter (PM2.5) at trace levels. The proposed method includes extraction of PM2.5-bound PFAS by microwave-assisted extraction (MAE) followed by centrifugation and injection into the liquid chromatograph coupled to a triple quadrupole tandem mass spectrometry system (LC-MS/MS). The main parameters affecting the performance of MAE were optimised using statistical design of experiments (DoE). Recoveries ranged from 83 to 120% and the method quantification limit (MQL) was 1.4 pg m(-3), when air volumes of 720 m(3) were sampled. This method was successfully applied to 41 samples collected from five stations of the monitoring network of the Valencian Regional Government (Spain) during April-July 2010. Eight out of 12 PFCs investigated were quantified in at least one sample (PFBA, PFPeA, PFHxS, 6:2 FTS, PFOA, PFNA, PFOS and PFDA). The measured concentrations ranged from 1.4 to 34.3 pg m(-3). Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Evaluating multiplexed quantitative phosphopeptide analysis on a hybrid quadrupole mass filter/linear ion trap/orbitrap mass spectrometer.

    Science.gov (United States)

    Erickson, Brian K; Jedrychowski, Mark P; McAlister, Graeme C; Everley, Robert A; Kunz, Ryan; Gygi, Steven P

    2015-01-20

    As a driver for many biological processes, phosphorylation remains an area of intense research interest. Advances in multiplexed quantitation utilizing isobaric tags (e.g., TMT and iTRAQ) have the potential to create a new paradigm in quantitative proteomics. New instrumentation and software are propelling these multiplexed workflows forward, which results in more accurate, sensitive, and reproducible quantitation across tens of thousands of phosphopeptides. This study assesses the performance of multiplexed quantitative phosphoproteomics on the Orbitrap Fusion mass spectrometer. Utilizing a two-phosphoproteome model of precursor ion interference, we assessed the accuracy of phosphopeptide quantitation across a variety of experimental approaches. These methods included the use of synchronous precursor selection (SPS) to enhance TMT reporter ion intensity and accuracy. We found that (i) ratio distortion remained a problem for phosphopeptide analysis in multiplexed quantitative workflows, (ii) ratio distortion can be overcome by the use of an SPS-MS3 scan, (iii) interfering ions generally possessed a different charge state than the target precursor, and (iv) selecting only the phosphate neutral loss peak (single notch) for the MS3 scan still provided accurate ratio measurements. Remarkably, these data suggest that the underlying cause of interference may not be due to coeluting and cofragmented peptides but instead from consistent, low level background fragmentation. Finally, as a proof-of-concept 10-plex experiment, we compared phosphopeptide levels from five murine brains to five livers. In total, the SPS-MS3 method quantified 38 247 phosphopeptides, corresponding to 11 000 phosphorylation sites. With 10 measurements recorded for each phosphopeptide, this equates to more than 628 000 binary comparisons collected in less than 48 h.

  11. Elucidation of urinary metabolites of fluoxymesterone by liquid chromatography-tandem mass spectrometry and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Pozo, Oscar J; Van Thuyne, Wim; Deventer, Koen; Van Eenoo, Peter; Delbeke, Frans T

    2008-03-01

    The suitability of liquid chromatography tandem mass spectrometry (LC-MS/MS) and gas chromatography mass spectrometry (GC-MS) for the elucidation of fluoxymesterone metabolism has been evaluated. Electrospray ionization (ESI) and collision induced dissociation (CID) fragmentation in LC-MS/MS and electron impact spectra (EI) in GC-MS have been studied for fluoxymesterone and two commercially available metabolites. MS(n) experiments and accurate mass measurements performed by an ion-trap analyser and a QTOF instrument respectively have been used for the elucidation of the fragmentation pathway. The neutral loss scan of 20 Da (loss of HF) in LC-MS/MS has been applied for the selective detection of fluoxymesterone metabolites. In a positive fluoxymesterone doping control sample, 9 different analytes have been detected including the parent compound. Seven of these metabolites were also confirmed by GC-MS including 5 previously unreported metabolites. On the basis of the ionization, the CID fragmentation, the accurate mass of the product ions and the EI spectra of these analytes, a tentative elucidation as well as a proposal for the metabolic pathway of fluoxymesterone has been suggested. The presence of these compounds has also been confirmed by the analysis of five other positive fluoxymesterone urine samples. Copyright (c) 2008 John Wiley & Sons, Ltd.

  12. Evaluation of the capabilities of atmospheric pressure chemical ionization source coupled to tandem mass spectrometry for the determination of dioxin-like polychlorobiphenyls in complex-matrix food samples.

    Science.gov (United States)

    Portolés, T; Sales, C; Abalos, M; Sauló, J; Abad, E

    2016-09-21

    The use of the novel atmospheric pressure chemical ionization (APCI) source for gas chromatography (GC) coupled to triple quadrupole using tandem mass spectrometry (MS/MS) and its potential for the simultaneous determination of the 12 dioxin-like polychlorobiphenyls (DL-PCBs) in complex food and feed matrices has been evaluated. In first place, ionization and fragmentation behavior of DL-PCBs on the APCI source under charge transfer conditions has been studied followed by their fragmentation in the collision cell. Linearity, repeatability and sensitivity have been studied obtaining instrumental limits of detection and quantification of 0.0025 and 0.005 pg μL(-1) (2.5 and 5 fg on column) respectively for every DL-PCB. Finally, application to real samples has been carried out and DL-PCB congeners (PCB 77, 81, 105, 114, 118, 123, 126, 156, 157, 167, 169, 189) have been detected in the different samples in the range of 0.40-10000 pg g(-1). GC-(APCI)MS/MS has been proved as a suitable alternative to the traditionally accepted confirmation method based on the use of high resolution mass spectrometry and other triple quadrupole tandem mass spectrometry techniques operating with electron ionization. The development of MS/MS methodologies for the analysis of dioxins and DL-PCBs is nowadays particularly important, since this technique was included as a confirmatory method in the present European Union regulations that establish the requirements for the determination of these compounds in food and feed matrices. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Practical Limitations of Aerosol Separation by a Tandem Differential Mobility Analyzer-Aerosol Particle Mass Analyzer.

    Science.gov (United States)

    Radney, James G; Zangmeister, Christopher D

    2016-01-01

    A cavity ring-down spectrometer and condensation particle counter were used to investigate the limitations in the separation of singly and multiply charged aerosol particles by a tandem differential mobility analyzer (DMA) and aerosol particle mass analyzer (APM). The impact of particle polydispersity and morphology was investigated using three materials: nearly-monodisperse polystyrene latex nanospheres (PSL); polydisperse, nearly-spherical ammonium sulfate (AS) and polydisperse lacey fractal soot agglomerates. PSL and AS particles were easily resolved as a function of charge. For fresh soot, the presence of multiply charged particles severely affects the isolation of the singly charged particles. In cases where the DMA-APM was unable to fully resolve the singly charged particles of interest, the peak mass deviated by up to 13 % leading to errors in the mass specific extinction cross section of over 100 %. For measurements of non-spherical particles, non-symmetrical distributions of concentration as a function of mass were a sign of the presence of multiply charged particles. Under these conditions, the effects of multiply charged particles can be reduced by using a second charge neutralizer after the DMA and prior to the APM. Dilution of the aerosol stream serves to decrease the total number concentration of particles and does not remove the contributions of multiply charged particles.

  14. Glucose and glycerol concentrations and their tracer enrichment measurements using liquid chromatography tandem mass spectrometry

    DEFF Research Database (Denmark)

    Bornø, Andreas; Foged, Lene; van Hall, Gerrit

    2014-01-01

    The present study describes a new liquid chromatography tandem mass spectrometry method for high-throughput quantification of glucose and glycerol in human plasma using stable isotopically labeled internal standards and is suitable for simultaneous measurements of glucose and glycerol enrichments...... in connection to in vivo metabolic studies investigating glucose turnover and lipolytic rate. Moreover, in order to keep up with this new fast analysis, simple derivatization procedures have been developed. Prior to analysis, glucose and glycerol were derivatized using benzoyl chloride in order to form...... benzoylated derivatives via new simplified fast procedures. For glucose, two internal standards were evaluated, [U-(13) C(6)]glucose and [U-(13) C(6), D(7)]glucose, and for glycerol, [U-(13) C(3), D(8)]glycerol was used. The method was validated by means of calibration curves, quality control samples...

  15. Analysis of bromate in drinking water using liquid chromatography-tandem mass spectrometry without sample pretreatment.

    Science.gov (United States)

    Kosaka, Koji; Asami, Mari; Takei, Kanako; Akiba, Michihiro

    2011-01-01

    An analytical method for determining bromate in drinking water was developed using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The (18)O-enriched bromate was used as an internal standard. The limit of quantification (LOQ) of bromate was 0.2 µg/L. The peak of bromate was separated from those of coexisting ions (i.e., chloride, nitrate and sulfate). The relative and absolute recoveries of bromate in two drinking water samples and in a synthesized ion solution (100 mg/L chloride, 10 mg N/L nitrate, and 100 mg/L sulfate) were 99-105 and 94-105%, respectively. Bromate concentrations in 11 drinking water samples determined by LC-MS/MS were water without sample pretreatment.

  16. Multiresidue determination of pesticides in fruit and vegetables by gas chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Gamón, M; Lleó, C; Ten, A; Mocholí, F

    2001-01-01

    Pesticide residues in fruit and vegetables were determined by gas chromatography/tandem mass spectrometry (GC/MS/MS). Electron impact (EI)/MS/MS and chemical ionization (CI)/MS/MS were developed for 80 compounds, including organochlorine, organophosphorus, organonitrogen, and pyrethroids, providing unambiguous spectral confirmation for these complex matrixes. Residues were extracted from samples with acetone followed by a mixture of dichloromethane-petroleum ether. Two injections per sample were required for analysis of the entire pesticide list by EI/MS/MS and CI/MS/MS. Initial steps involving cleanup and concentration of extracts were eliminated. The excellent selectivity and good linearity allowed quantification and identification of low levels of pesticides in the most difficult matrixes. The method has been used for routine analysis of many vegetables.

  17. Determination of dapsone in meat and milk by liquid chromatography tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Hadjigeorgiou, M. [State General Laboratory of Cyprus, Veterinary Drug Residues Lab, Kimonos 44, 1451 Nicosia (Cyprus)], E-mail: mhadjigeorgiou@sgl.moh.gov.cy; Papachrysostomou, Ch.; Theodorou, Z.; Kanari, P.; Constantinou, S. [State General Laboratory of Cyprus, Veterinary Drug Residues Lab, Kimonos 44, 1451 Nicosia (Cyprus)

    2009-04-01

    Within the EU the use of dapsone (4,4-diaminodiphenylsulfone) is prohibited in food-producing animals and consequently it's included in the Annex IV of the Directive 90/2377/EC. A quantitative confirmatory method has been developed and validated according to the criteria defined in the Commission Decision 2002/657/EC, for the determination of dapsone in meat and milk. Samples, after homogenization in alkaline conditions and organic solvent extraction, were purified on silica gel solid phase extraction cartridges. The eluate was evaporated and redissolved in mobile phase and was analysed by liquid chromatography tandem mass spectrometry (LC-MS/MS) in positive electrospray ionisation (ESI) using deuterium labelled Sulphadimidine-d7 as internal standard. The calculated value for, decision limit, CC{alpha} is 0.12 {mu}g kg{sup -1}, and the detection capability; CC{beta} value is 0.16 {mu}g kg{sup -1}.

  18. [Neonatal onset of organic acidemia (propionic) diagnosed by tandem mass spectrometry].

    Science.gov (United States)

    Cifuentes, Yolanda; De la Hoz, Isabel; Bermúdez, Martha; Arteaga, Clara

    2008-03-01

    Propionic acidemia is an autosomal recessive disorder as a result of a deficient activity of propionyl-CoA carboxylase. Propionyl CoA is metabolized by propionyl-CoA carboxylase to methylmalonyl CoA. Propionic acidemia is a major cause of ketotic hyperglycinemia. This disorder is characterized by episodic vomiting, dehydratation, feeding intolerante, lethargy, hypotonia, metabolic acidosis, ketosis and hyperammonemia. The patient presented herein was a full-term female newborn with encephalopathy in the first days of life. She presented hypoglycemia, metabolic acidosis with increased anion gap, ketosis, hyperammonemia, anemia, leukopenia and thrombocytopenia. The brain ultrasonography was normal. The tandem mass expectrometry done by Pediatrix was abnormal, with the acylcarnitine results consistent with an organic acidemia. The parents are consanguineus and have a history of abortus, miscarriage and neonatal death, characteristics suggestive of the presence of genetic defects.

  19. Determination of dapsone in meat and milk by liquid chromatography tandem mass spectrometry

    International Nuclear Information System (INIS)

    Hadjigeorgiou, M.; Papachrysostomou, Ch.; Theodorou, Z.; Kanari, P.; Constantinou, S.

    2009-01-01

    Within the EU the use of dapsone (4,4-diaminodiphenylsulfone) is prohibited in food-producing animals and consequently it's included in the Annex IV of the Directive 90/2377/EC. A quantitative confirmatory method has been developed and validated according to the criteria defined in the Commission Decision 2002/657/EC, for the determination of dapsone in meat and milk. Samples, after homogenization in alkaline conditions and organic solvent extraction, were purified on silica gel solid phase extraction cartridges. The eluate was evaporated and redissolved in mobile phase and was analysed by liquid chromatography tandem mass spectrometry (LC-MS/MS) in positive electrospray ionisation (ESI) using deuterium labelled Sulphadimidine-d7 as internal standard. The calculated value for, decision limit, CCα is 0.12 μg kg -1 , and the detection capability; CCβ value is 0.16 μg kg -1

  20. Pressurized liquid extraction followed by liquid chromatography with tandem mass spectrometry to determine pharmaceuticals in mussels.

    Science.gov (United States)

    Núñez, Mireia; Borrull, Francesc; Pocurull, Eva; Fontanals, Núria

    2016-02-01

    An analytical method based on pressurized liquid extraction and solid-phase extraction with a mixed-mode Oasis(®) MAX sorbent as cleanup, followed by liquid chromatography with electrospray ionization and tandem mass spectrometry was developed and validated for the determination of seven widely used pharmaceuticals in mussel species. The optimization of the pressurized liquid extraction and the solid-phase extraction parameters is described. The method provided extraction recoveries ranging from 61 to 90%, and limits of detection ranging from 2 to 50 ng/g (dry weight). The repeatability and reproducibility of the method, expressed as relative standard deviation, were lower than 15 and 19%, respectively. The method was successfully applied to the analysis of mussel samples from different locations. The analyses showed that salicylic acid was present in mussels at concentrations up to 177 ng/g (dry weight). © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Tandem Mass Spectrometry Detection of Quorum Sensing Activity in Multidrug Resistant Clinical Isolate Acinetobacter baumannii

    Directory of Open Access Journals (Sweden)

    Kok-Gan Chan

    2014-01-01

    Full Text Available Many Proteobacteria communicate via production followed by response of quorum sensing molecules, namely, N-acyl homoserine lactones (AHLs. These molecules consist of a lactone moiety with N-acyl side chain with various chain lengths and degrees of saturation at C-3 position. AHL-dependent QS is often associated with regulation of diverse bacterial phenotypes including the expression of virulence factors. With the use of biosensor and high resolution liquid chromatography tandem mass spectrometry, the AHL production of clinical isolate A. baumannii 4KT was studied. Production of short chain AHL, namely, N-hexanoyl-homoserine lactone (C6-HSL and N-octanoyl-homoserine lactone (C8-HSL, was detected.

  2. A dedicated AMS setup for medium mass isotopes at the Cologne FN tandem accelerator

    Science.gov (United States)

    Schiffer, M.; Altenkirch, R.; Feuerstein, C.; Müller-Gatermann, C.; Hackenberg, G.; Herb, S.; Bhandari, P.; Heinze, S.; Stolz, A.; Dewald, A.

    2017-09-01

    AMS measurements of medium mass isotopes, e.g. of 53Mn and 60Fe, are gaining interest in various fields of operation, especially geoscience. Therefore a dedicated AMS setup has been built at the Cologne 10 MV FN tandem accelerator. This setup is designed to obtain a sufficient suppression of the stable isobars at energies around 100 MeV. In this contribution we report on the actual status of the new setup and the first in-beam tests of its individual components. The isobar suppression is done with (dE/dx) techniques using combinations of energy degrader foils with an electrostatic analyzer (ESA) and a time of flight (ToF) system, as well as a (dE/dx),E gas ionization detector. Furthermore, the upgraded ion source and its negative ion yield measurement for MnO- are presented.

  3. Determination of ractopamine and salbutamol in pig hair by liquid chromatography tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Kai-Chun Chang

    2018-04-01

    Full Text Available A liquid chromatography tandem mass spectrometric method was developed for the determination of two β-agonists (ractopamine and salbutamol in pig hair samples. An isotope of ractopamine-d5 or salbutamol-d6 as an internal standard was used to carry out quantitative analysis. Concentrated sodium hydroxide was used to pretreat hair samples and then purified by the solid phase extraction (SPE procedure. The extracted solution was evaporated and reconstituted for injection in the instrument with electrospray ionization (ESI operating in a positive multiple-reaction-monitoring (MRM mode. Ractopamine and salbutamol separation were performed on C18 analytical column under gradient condition. The internal standard calibration curve was linear in the range of concentration from 0.5 to 100 ng mL−1 (R2 > 0.995. Recoveries of this method estimated at three spiked concentrations of 100, 250 and 500 ng mL−1 in pig hair samples, were 79–82% for ractopamine and 77–96% for salbutamol. The corresponding inter-day and intra-day precisions expressed as relative standard deviation (RSD % were 3.8–6.4% and 3.8–8.6%, respectively. The analytical time for one sample was 8 min. The detection limit of this method was 0.6 and 8.3 ng mL−1 for ractopamine and salbutamol, respectively. This developed method can be applied for monitoring the use of the β-agonists salbutamol and ractopamine in swine feed incurred pig hair. Keywords: Salbutamol, Ractopamine, Hair, Tandem mass

  4. Plasma free and total carnitine measured in children by tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    J.H. Osorio

    2002-11-01

    Full Text Available Free and total carnitine quantification is important as a complementary test for the diagnosis of unusual metabolic diseases, including fatty acid degradation disorders. The present study reports a new method for the quantification of free and total carnitine in dried plasma specimens by isotope dilution electrospray tandem mass spectrometry with sample derivatization. Carnitine is determined by looking for the precursor of ions of m/z = 103 of N-butylester derivative, and the method is validated by comparison with radioenzymatic assay. We obtained an inter- and intra-day assay coefficient of variation of 4.3 and 2.3, respectively. Free and total carnitine was analyzed in 309 dried plasma spot samples from children ranging in age from newborn to 14 years using the new method, which was found to be suitable for calculating reference age-related values for free and total carnitine (less than one month: 19.3 ± 2.4 and 23.5 ± 2.9; one to twelve months: 28.8 ± 10.2 and 35.9 ± 11.4; one to seven years: 30.7 ± 10.3 and 38.1 ± 11.9; seven to 14 years: 33.7 ± 11.6, and 43.1 ± 13.8 µM, respectively. No difference was found between males and females. A significant difference was observed between neonates and the other age groups. We compare our data with reference values in the literature, most of them obtained by radioenzymatic assay. However, this method is laborious and time consuming. The electrospray tandem mass spectrometry method presented here is a reliable, rapid and automated procedure for carnitine quantitation.

  5. Compound-specific chlorine isotope analysis: a comparison of gas chromatography/isotope ratio mass spectrometry and gas chromatography/quadrupole mass spectrometry methods in an interlaboratory study.

    Science.gov (United States)

    Bernstein, Anat; Shouakar-Stash, Orfan; Ebert, Karin; Laskov, Christine; Hunkeler, Daniel; Jeannottat, Simon; Sakaguchi-Söder, Kaori; Laaks, Jens; Jochmann, Maik A; Cretnik, Stefan; Jager, Johannes; Haderlein, Stefan B; Schmidt, Torsten C; Aravena, Ramon; Elsner, Martin

    2011-10-15

    Chlorine isotope analysis of chlorinated hydrocarbons like trichloroethylene (TCE) is of emerging demand because these species are important environmental pollutants. Continuous flow analysis of noncombusted TCE molecules, either by gas chromatography/isotope ratio mass spectrometry (GC/IRMS) or by GC/quadrupole mass spectrometry (GC/qMS), was recently brought forward as innovative analytical solution. Despite early implementations, a benchmark for routine applications has been missing. This study systematically compared the performance of GC/qMS versus GC/IRMS in six laboratories involving eight different instruments (GC/IRMS, Isoprime and Thermo MAT-253; GC/qMS, Agilent 5973N, two Agilent 5975C, two Thermo DSQII, and one Thermo DSQI). Calibrations of (37)Cl/(35)Cl instrument data against the international SMOC scale (Standard Mean Ocean Chloride) deviated between instruments and over time. Therefore, at least two calibration standards are required to obtain true differences between samples. Amount dependency of δ(37)Cl was pronounced for some instruments, but could be eliminated by corrections, or by adjusting amplitudes of standards and samples. Precision decreased in the order GC/IRMS (1σ ≈ 0.1‰), to GC/qMS (1σ ≈ 0.2-0.5‰ for Agilent GC/qMS and 1σ ≈ 0.2-0.9‰ for Thermo GC/qMS). Nonetheless, δ(37)Cl values between laboratories showed good agreement when the same external standards were used. These results lend confidence to the methods and may serve as a benchmark for future applications. © 2011 American Chemical Society

  6. mMass as a Software Tool for the Annotation of Cyclic Peptide Tandem Mass Spectra

    Czech Academy of Sciences Publication Activity Database

    Niedermeyer, T. H. J.; Strohalm, Martin

    2012-01-01

    Roč. 7, č. 9 (2012), e44913 E-ISSN 1932-6203 R&D Projects: GA MŠk(CZ) ME10013 Institutional research plan: CEZ:AV0Z50200510 Keywords : cyclic peptide s * nMass Subject RIV: CE - Biochemistry Impact factor: 3.730, year: 2012

  7. Monitoring salivary melatonin concentrations in children with sleep disorders using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Khan, Sohil A; George, Rani; Charles, Bruce G; Taylor, Paul J; Heussler, Helen S; Cooper, David M; McGuire, Treasure M; Pache, David; Norris, Ross L G

    2013-06-01

    Melatonin is synthesized in the pineal gland and is an important circadian phase marker, especially in the determination of sleep patterns. Both temporary and permanent abnormal sleep patterns occur in children; therefore, it is desirable to have methods for monitoring melatonin in biological fluids in the diagnosis and treatment of such disorders. The objective of the study is to develop a liquid chromatography-tandem mass spectrometry method for the determination of melatonin in saliva and to apply it to monitoring salivary concentrations in children with sleep disorders. A deuterated internal standard (d7-melatonin) was added to a diluted saliva sample (20 µL) in an autosampler vial insert, and 50 µL were injected. Plasticware was strictly avoided, and all glassware was scrupulously cleaned and then baked at 120°C for at least 48 hours to obtain satisfactory performance. Reverse-phase chromatography was performed on a C8 column using a linear gradient elution profile comprising mobile phases A (0.1% aqueous formic acid) and B (15% methanol in acetonitrile containing 0.1% formic acid), pumped at a total flow rate of 0.8 mL/min. The run time was 8 minutes. After atmospheric pressure chemical ionization, mass spectrometric detection was in positive ion mode. Mass detection was by selected reaction monitoring mode with the following mass transitions used for quantification: melatonin, m/z 233.0 → 173.8 and d7-melatonin, m/z 240.0 → 178.3. Linearity (r > 0.999) was established from 3.9 to 1000 pg/mL. Imprecision (coefficient of variation percent) was less than 11%, and accuracy was 100-105% (7.0-900 pg/mL). The method was selective, and the mean (range) ratio of the slopes of calibrations in water to those in daytime saliva samples collected from 10 healthy adult subjects was 0.989 (0.982-0.997), indicating negligible matrix effects. The application of the assay was demonstrated in healthy adults and in children being clinically investigated for sleep

  8. Use of liquid chromatography/electrospray ionization tandem mass spectrometry to study the degradation pathways of terbuthylazine (TER) by Typha latifolia in constructed wetlands: identification of a new TER metabolite.

    Science.gov (United States)

    Gikas, Evagelos; Papadopoulos, Nikolaos G; Bazoti, Fotini N; Zalidis, Georgios; Tsarbopoulos, Anthony

    2012-01-30

    S-Triazines are used worldwide as herbicides for agricultural and non-agricultural purposes. Although terbuthylazine (TER) is the second most frequently used S-triazine, there is limited information on its metabolism. For this reason, an analytical method based on liquid chromatography/electrospray ionization tandem mass spectrometry (LC-ESI MS/MS) has been developed aiming at the identification of TER and its five major metabolites (desisopropyl-hydroxy-atrazine, desethyl-hydroxy-terbuthylazine, desisopropyl-atrazine, hydroxy-terbuthylazine and desethyl-terbuthylazine) in constructed wetland water samples. The separation of TER and its major metabolites was performed by reversed-phase high-performance liquid chromatography (HPLC) on a C(8) column using a gradient elution of aqueous acetic acid 1% (solvent A) and acetonitrile (solvent B), followed by MS/MS analysis on a triple quadrupole mass spectrometer. The data-depended analysis (DDA) scan approach has been employed and the main degradation pathways of both hydroxyl and chloro (dealkylated and alkylated) metabolites are elucidated through the tandem mass spectral (MS/MS) interpretation of triazine fragments under CID conditions. In addition, another major metabolite of TER, namely N2-tert-butyl-N4-ethyl-6-methoxy-1,3,5-triazine-2,4-diamine, has been identified. This methodology can be further employed in biodegradation studies of TER, thus assisting the assessment of its environmental impact. Copyright © 2011 John Wiley & Sons, Ltd.

  9. Exploiting the multiplexing capabilities of tandem mass tags for high-throughput estimation of cellular protein abundances by mass spectrometry.

    Science.gov (United States)

    Ahrné, Erik; Martinez-Segura, Amalia; Syed, Afzal Pasha; Vina-Vilaseca, Arnau; Gruber, Andreas J; Marguerat, Samuel; Schmidt, Alexander

    2015-09-01

    The generation of dynamic models of biological processes critically depends on the determination of precise cellular concentrations of biomolecules. Measurements of system-wide absolute protein levels are particularly valuable information in systems biology. Recently, mass spectrometry based proteomics approaches have been developed to estimate protein concentrations on a proteome-wide scale. However, for very complex proteomes, fractionation steps are required, increasing samples number and instrument analysis time. As a result, the number of full proteomes that can be routinely analyzed is limited. Here we combined absolute quantification strategies with the multiplexing capabilities of isobaric tandem mass tags to determine cellular protein abundances in a high throughput and proteome-wide scale even for highly complex biological systems, such as a whole human cell line. We generated two independent data sets to demonstrate the power of the approach regarding sample throughput, dynamic range, quantitative precision and accuracy as well as proteome coverage in comparison to existing mass spectrometry based strategies. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Sensitive liquid chromatography-tandem mass spectrometry method for quantification of hydrochlorothiazide in human plasma.

    Science.gov (United States)

    Ramakrishna, N V S; Vishwottam, K N; Manoj, S; Koteshwara, M; Wishu, S; Varma, D P

    2005-12-01

    A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of hydrochlorothiazide (I), a common diuretic and anti-hypertensive agent. The analyte and internal standard, tamsulosin (II) were extracted by liquid-liquid extraction with diethyl ether-dichloromethane (70:30, v/v) using a Glas-Col Multi-Pulse Vortexer. The chromatographic separation was performed on a reversed-phase column (Waters symmetry C18) with a mobile phase of 10 mm ammonium acetate-methanol (15:85, v/v). The protonated analyte was quantitated in negative ionization by multiple reaction monitoring with a mass spectrometer. The mass transitions m/z 296.1 solidus in circle 205.0 and m/z 407.2 solidus in circle 184.9 were used to measure I and II, respectively. The assay exhibited a linear dynamic range of 0.5-200 ng/mL for hydrochlorothiazide in human plasma. The lower limit of quantitation was 500 pg/mL, with a relative standard deviation of less than 9%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. A run time of 2.5 min for each sample made it possible to analyze a throughput of more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies. (c) 2005 John Wiley & Sons, Ltd.

  11. Simultaneous determination of ramipril, ramiprilat and telmisartan in human plasma using liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Gupta, V K; Jain, Rajeev; Lukram, Ojitkumar; Agarwal, Shilpi; Dwivedi, Ashish

    2011-01-15

    A rapid and sensitive liquid chromatography tandem mass spectrometry method has been developed and validated for the simultaneous determination of ramipril, ramiprilat and telmisartan in human plasma. The solid-phase extraction technique was used for the extraction of ramipril, ramiprilat and telmisartan from human plasma. Trandolaprilat and hydrochlorothiazide were used as the internal standards (ISs). Chromatography was performed on a Hypurity C18, 5 μm, 50 mm × 4.6mm column, with the mobile phase consisting of ammonium acetate and acetonitrile (in a 20:80 ratio), followed by detection using mass spectrometry. The method involves a simple reversed isocratic chromatography condition and mass spectrometry detection, which enables detection at sub-nanogram levels. The method was validated and the lower limit of quantification for ramipril, ramiprilat and telmisartan was found to be 0.1 ng mL(-1), 0.1 ng mL(-1) and 2 ng mL(-1), respectively. The mean recovery for ramipril, ramiprilat and telmisartan ranged from 90.1 to 104.1%. This method increased the sensitivity and selectivity; resulting in high-throughput analysis of ramipril, ramiprilat and telmisartan using two different ISs in a single experiment for bioequivalence studies, with a chromatographic run time of 1.5 min only. Copyright © 2010 Elsevier B.V. All rights reserved.

  12. Characterization of N,N-dimethyl amino acids by electrospray ionization-tandem mass spectrometry.

    Science.gov (United States)

    Naresh Chary, V; Sudarshana Reddy, B; Kumar, Ch Dinesh; Srinivas, R; Prabhakar, S

    2015-05-01

    Methylation is an essential metabolic process for a number of critical reactions in the body. Methyl groups are involved in the healthy function of the body life processes, by conducting methylation process involving specific enzymes. In these processes, various amino acids are methylated, and the occurrence of methylated amino acids in nature is diverse. Nowadays, mass-spectrometric-based identification of small molecules as biomarkers for diseases is a growing research. Although all dimethyl amino acids are metabolically important molecules, mass spectral data are available only for a few of them in the literature. In this study, we report synthesis and characterization of all dimethyl amino acids, by electrospray ionization-tandem mass spectrometry (MS/MS) experiments on protonated molecules. The MS/MS spectra of all the studied dimethyl amino acids showed preliminary loss of H2O + CO to form corresponding immonium ions. The other product ions in the spectra are highly characteristic of the methyl groups on the nitrogen and side chain of the amino acids. The amino acids, which are isomeric and isobaric with the studied dimethyl amino acids, gave distinctive MS/MS spectra. The study also included MS/MS analysis of immonium ions of dimethyl amino acids that provide information on side chain structure, and it is further tested to determine the N-terminal amino acid of the peptides. Copyright © 2015 John Wiley & Sons, Ltd.

  13. Development and validation of liquid chromatography combined with tandem mass spectrometry methods for the quantitation of simalikalactone E in extracts of Quassia amara L. and in mouse blood.

    Science.gov (United States)

    Le, Hong Luyen; Jullian, Valérie; Claparols, Catherine; Vansteelandt, Marieke; Haddad, Mohamed; Cabou, Cendrine; Deharo, Eric; Fabre, Nicolas

    2015-01-01

    Simalikalactone E (SkE) from Quassia amara, has been proved to be a valuable anti-malarial and anti-cancer compound. As SkE is very scarce, methods of quantitation are needed in order to optimise its isolation process and to determine pharmacokinetic data. To validate methods using liquid chromatography coupled to mass spectrometry for the quantitation of SkE in plant extracts and in biological fluids. High- and ultrahigh-performance liquid chromatography (UHPLC) coupled to ion trap mass spectrometry (MS) with single ion monitoring detection and to triple quadrupole-linear ion trap tandem mass spectrometry with multiple reaction monitoring detection methods were developed. Validation procedure was realised according to the International Conference on Harmonisation guideline. Methanol extracts of dried Quassia amara leaves, and mouse-blood samples obtained after various routes of administration, were analysed for SkE. Methods were validated and gave similar results regarding the content of SkE expressed per kilogram of dry leaves in the traditional decoction (160 ± 12 mg/kg) and in the methanol extract (93 ± 2 mg/kg). The recovery of the analyte from mouse blood ranged from 80.7 to 119.8%. Simalikalactone E was only detected using UHPLC-MS/MS (0.2 ± 0.03 mg/L) in mouse blood after intravenous injection: none was detected following intraperitoneal or oral gavage administration of SkE. The LC-MS methods were used for the quantitation of SkE in plant extracts and in mouse blood. These methods open the way for further protocol optimisation of SkE extraction and the determination of its pharmacokinetic data. Copyright © 2014 John Wiley & Sons, Ltd.

  14. Sensitive and selective liquid chromatography-tandem mass spectrometry method for the determination of five ganoderic acids in Ganoderma lucidum and its related species.

    Science.gov (United States)

    Liu, Yongli; Liu, Youping; Qiu, Feng; Di, Xin

    2011-03-25

    The present paper describes a novel, sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous analysis of ganoderic acids C(2), B, A, H, D in Ganoderma lucidum and its related species. Ganoderma samples were prepared using simple ultrasonic extraction. Chromatographic separation was carried out on an Agilent Zorbax XDB C(18) column (250 mm × 4.6 mm i.d., 5μm) with an isocratic mobile phase consisting of acetonitrile, water and formic acid (42:58:0.5, v/v/v). Mass spectrometric detection was achieved by a triple-quadrupole mass spectrometer equipped with an atmospheric pressure chemical ionization (APCI) interface operating in negative and positive ionization mode via a single within-run polarity switching. Quantitation of five ganoderic acids was performed using selective reaction monitoring (SRM) mode. The intra- and inter-day precision was less than 6.2% and the accuracy ranged from 90.0% to 105.7%. The limit of quantification (LOQ) was 20.0-40.0 ng/mL and the limit of detection (LOD) was 3.0-25.0 ng/mL. With this method, low levels of ganoderic acids in the fruiting bodies of Ganoderma sinense and Ganoderma applanatum were accurately quantified for the first time. Importantly, the method allows unequivocal quantification of the five ganoderic acids in the spores and fruiting bodies of Ganoderma lucidum, whereas the previously published methods have lacked the capability. The method presented will be a powerful tool for quality control of Ganoderma lucidum and its related species. Copyright © 2010 Elsevier B.V. All rights reserved.

  15. Functional group composition of ambient and source organic aerosols determined by tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    J. Dron

    2010-08-01

    Full Text Available The functional group composition of various organic aerosols (OA is investigated using a recently developed analytical approach based on atmospheric pressure chemical ionisation-tandem mass spectrometry (APCI-MS/MS. The determinations of three functional groups contents are performed quantitatively by neutral loss (carboxylic and carbonyl groups, R-COOH and R-CO-R´ respectively and precursor ion (nitro groups, R-NO2 scanning modes of a tandem mass spectrometer. Major organic aerosol sources are studied: vehicular emission and wood combustion for primary aerosol sources; and a secondary organic aerosol (SOA produced through photooxidation of o-xylene. The results reveal significant differences in the functional group contents of these source aerosols. The laboratory generated SOA is dominated by carbonyls while carboxylics are preponderate in the wood combustion particles. On the other hand, vehicular emissions are characterised by a strong nitro content. The total amount of the three functional groups accounts for 1.7% (vehicular to 13.5% (o-xylene photooxidation of the organic carbon. Diagnostic functional group ratios are then used to tentatively discriminate sources of particles collected in an urban background environment located in an Alpine valley (Chamonix, France during a strong winter pollution event. The three functional groups under study account for a total functionalisation rate of 2.2 to 3.8% of the organic carbon in this ambient aerosol, which is also dominated by carboxylic moieties. In this particular case study of a deep alpine valley during winter, we show that the nitro- and carbonyl-to-carboxylic diagnostic ratios can be a useful tool to discriminate sources. In these conditions, the total OA concentrations are highly dominated by wood combustion OA. This result is confirmed by an organic markers source apportionment approach which assess a wood burning organic carbon contribution of about 60

  16. Functional group composition of ambient and source organic aerosols determined by tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Dron, J.; El Haddad, I.; Temime-Roussel, B.; Wortham, H.; Marchand, N. [Univ Aix Marseille, CNRS, Lab Chim Provence, Equipe Instrumentat and React Atmospher, UMR 6264, F-13331 Marseille 3 (France); Jaffrezo, J.L. [Univ Grenoble 1, CNRS, UMR 5183, Lab Glaciol and Geophys Environm, F-38402 St Martin Dheres (France)

    2010-07-01

    The functional group composition of various organic aerosols (OA) is investigated using a recently developed analytical approach based on atmospheric pressure chemical ionisation-tandem mass spectrometry (APCIMS/MS). The determinations of three functional groups contents are performed quantitatively by neutral loss (carboxylic and carbonyl groups, R-COOH and R-CO-R' respectively) and precursor ion (nitro groups, R-NO{sub 2}) scanning modes of a tandem mass spectrometer. Major organic aerosol sources are studied: vehicular emission and wood combustion for primary aerosol sources; and a secondary organic aerosol (SOA) produced through photooxidation of o-xylene. The results reveal significant differences in the functional group contents of these source aerosols. The laboratory generated SOA is dominated by carbonyls while carboxylics are preponderate in the wood combustion particles. On the other hand, vehicular emissions are characterised by a strong nitro content. The total amount of the three functional groups accounts for 1.7% (vehicular) to 13.5% (o-xylene photooxidation) of the organic carbon. Diagnostic functional group ratios are then used to tentatively discriminate sources of particles collected in an urban background environment located in an Alpine valley (Chamonix, France) during a strong winter pollution event. The three functional groups under study account for a total functionalization rate of 2.2 to 3.8% of the organic carbon in this ambient aerosol, which is also dominated by carboxylic moieties. In this particular case study of a deep alpine valley during winter, we show that the nitro- and carbonyl-to-carboxylic diagnostic ratios can be a useful tool to discriminate sources. In these conditions, the total OA concentrations are highly dominated by wood combustion OA. This result is confirmed by an organic markers source apportionment approach which assess a wood burning organic carbon contribution of about 60%. Finally, examples of functional

  17. Characterization of sulfur mustard induced structural modifications in human hemoglobin by liquid chromatography-tandem mass spectrometry

    NARCIS (Netherlands)

    Noort, D.; Verheij, E.R.; Hulst, A.G.; Jong, L.P.A. de; Benschop, H.P.

    1996-01-01

    In this paper we describe the use of tandem mass spectrometry to identify modified sites in human hemoglobin after in vitro exposure to bis(2- chloroethyl) sulfide (sulfur mustard). Globin isolated from human whole blood which had been exposed to sulfur mustard was degraded with trypsin, and the

  18. Clinical validation of cutoff target ranges in newborn screening of metabolic disorders by tandem mass spectrometry : A worldwide collaborative project

    NARCIS (Netherlands)

    McHugh, David M. S.; Cameron, Cynthia A.; Abdenur, Jose E.; Abdulrahman, Mahera; Adair, Ona; Al Nuaimi, Shahira Ahmed; Ahlman, Henrik; Allen, Jennifer J.; Antonozzi, Italo; Archer, Shaina; Au, Sylvia; Auray-Blais, Christiane; Baker, Mei; Bamforth, Fiona; Beckmann, Kinga; Pino, Gessi Bentz; Berberich, Stanton L.; Binard, Robert; Boemer, Francois; Bonham, Jim; Breen, Nancy N.; Bryant, Sandra C.; Caggana, Michele; Caldwell, S. Graham; Camilot, Marta; Campbell, Carlene; Carducci, Claudia; Cariappa, Rohit; Carlisle, Clover; Caruso, Ubaldo; Cassanello, Michela; Miren Castilla, Ane; Castineiras Ramos, Daisy E.; Chakraborty, Pranesh; Chandrasekar, Ram; Ramos, Alfredo Chardon; Cheillan, David; Chien, Yin-Hsiu; Childs, Thomas A.; Chrastina, Petr; Sica, Yuri Cleverthon; Cocho de Juan, Jose Angel; Elena Colandre, Maria; Cornejo Espinoza, Veronica; Corso, Gaetano; Currier, Robert; Cyr, Denis; Czuczy, Noemi; D'Apolito, Oceania; Davis, Tim; de Sain-Van der Velden, Monique G.; Delgado Pecellin, Carmen; Di Gangi, Iole Maria; Di Stefano, Cristina Maria; Dotsikas, Yannis; Downing, Melanie; Downs, Stephen M.; Dy, Bonifacio; Dymerski, Mark; Rueda, Inmaculada; Elvers, Bert; Eaton, Roger; Eckerd, Barbara M.; El Mougy, Fatma; Eroh, Sarah; Espada, Mercedes; Evans, Catherine; Fawbush, Sandy; Fijolek, Kristel F.; Fisher, Lawrence; Franzson, Leifur; Frazier, Dianne M.; Garcia, Luciana R. C.; Garcia-Valdecasas Bermejo, Maria Sierra; Gavrilov, Dimitar; Gerace, Rosemarie; Giordano, Giuseppe; Irazabal, Yolanda Gonzalez; Greed, Lawrence C.; Grier, Robert; Grycki, Elyse; Gu, Xuefan; Gulamali-Majid, Fizza; Hagar, Arthur F.; Han, Lianshu; Hannon, W. Harry; Haslip, Christa; Hassan, Fayza Abdelhamid; He, Miao; Hietala, Amy; Himstedt, Leslie; Hoffman, Gary L.; Hoffman, William; Hoggatt, Philis; Hopkins, Patrick V.; Hougaard, David M.; Hughes, Kerie; Hunt, Patricia R.; Hwu, Wuh-Liang; Hynes, June; Ibarra-Gonzalez, Isabel; Ingham, Cindy A.; Ivanova, Maria; Jacox, Ward B.; John, Catharine; Johnson, John P.; Jonsson, Jon J.; Karg, Eszter; Kasper, David; Klopper, Brenda; Katakouzinos, Dimitris; Khneisser, Issam; Knoll, Detlef; Kobayashi, Hirinori; Koneski, Ronald; Kozich, Viktor; Kouapei, Rasoul; Kohlmueller, Dirk; Kremensky, Ivo; la Marca, Giancarlo; Lavochkin, Marcia; Lee, Soo-Youn; Lehotay, Denis C.; Lemes, Aida; Lepage, Joyce; Lesko, Barbara; Lewis, Barry; Lim, Carol; Linard, Sharon; Lindner, Martin; Lloyd-Puryear, Michele A.; Lorey, Fred; Loukas, Yannis L.; Luedtke, Julie; Maffitt, Neil; Magee, J. Fergall; Manning, Adrienne; Manos, Shawn; Marie, Sandrine; Hadachi, Sonia Marchezi; Marquardt, Gregg; Martin, Stephen J.; Matern, Dietrich; Gibson, Stephanie K. Mayfield; Mayne, Philip; McCallister, Tonya D.; McCann, Mark; McClure, Julie; McGill, James J.; McKeever, Christine D.; McNeilly, Barbara; Morrissey, Mark A.; Moutsatsou, Paraskevi; Mulcahy, Eleanor A.; Nikoloudis, Dimitris; Norgaard-Pedersen, Bent; Oglesbee, Devin; Oltarzewski, Mariusz; Ombrone, Daniela; Ojodu, Jelili; Papakonstantinou, Vagelis; Reoyo, Sherly Pardo; Park, Hyung-Doo; Pasquali, Marzia; Pasquini, Elisabetta; Patel, Pallavi; Pass, Kenneth A.; Peterson, Colleen; Pettersen, Rolf D.; Pitt, James J.; Poh, Sherry; Pollak, Arnold; Porter, Cory; Poston, Philip A.; Price, Ricky W.; Queijo, Cecilia; Quesada, Jonessy; Randell, Edward; Ranieri, Enzo; Raymond, Kimiyo; Reddic, John E.; Reuben, Alejandra; Ricciardi, Charla; Rinaldo, Piero; Rivera, Jeff D.; Roberts, Alicia; Rocha, Hugo; Roche, Geraldine; Greenberg, Cheryl Rochman; Egea Mellado, Jose Maria; Jess Juan-Fita, Maria; Ruiz, Consuelo; Ruoppolo, Margherita; Rutledge, S. Lane; Ryu, Euijung; Saban, Christine; Sahai, Inderneel; Salazar Garcia-Blanco, Maria Isabel; Santiago-Borrero, Pedro; Schenone, Andrea; Schoos, Roland; Schweitzer, Barb; Scott, Patricia; Seashore, Margretta R.; Seeterlin, Mary A.; Sesser, David E.; Sevier, Darrin W.; Shone, Scott M.; Sinclair, Graham; Skrinska, Victor A.; Stanley, Eleanor L.; Strovel, Erin T.; Jones, April L. Studinski; Sunny, Sherlykutty; Takats, Zoltan; Tanyalcin, Tijen; Teofoli, Francesca; Thompson, J. Robert; Tomashitis, Kathy; Domingos, Mouseline Torquado; Torres, Jasmin; Torres, Rosario; Tortorelli, Silvia; Turi, Sandor; Turner, Kimberley; Tzanakos, Nick; Valiente, Alf G.; Vallance, Hillary; Vela-Amieva, Marcela; Vilarinho, Laura; von Doebeln, Ulrika; Vincent, Marie-Francoise; Vorster, B. Chris; Watson, Michael S.; Webster, Dianne; Weiss, Sheila; Wilcken, Bridget; Wiley, Veronica; Williams, Sharon K.; Willis, Sharon A.; Woontner, Michael; Wright, Katherine; Yahyaoui, Raquel; Yamaguchi, Seiji; Yssel, Melissa; Zakowicz, Wendy M.

    Purpose: To achieve clinical validation of cutoff values for newborn screening by tandem mass spectrometry through a worldwide collaborative effort. Methods: Cumulative percentiles of amino acids and acylcarnitines in dried blood spots of approximately 25-30 million normal newborns and 10,742

  19. Quantification of antidepressants and antipsychotics in human serum by precipitation and ultra high pressure liquid chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Hasselstrøm, Jørgen Bo

    2011-01-01

    precipitated with zinc sulphate and methanol containing a stable isotope labelled analog for each analyte. Quantitative analysis was performed by ultra high pressure liquid chromatography combined with a tandem mass spectrometer using a Zorbax SB-C8 column (2.0×50mm; 1.8m) with a mobile phase consisting of 0...

  20. Profiling ABA metabolites in Nicotiana tabacum L. leaves by ultra-performance liquid chromatography–electrospray tandem mass spectrometry

    Czech Academy of Sciences Publication Activity Database

    Turečková, Veronika; Novák, Ondřej; Strnad, Miroslav

    2009-01-01

    Roč. 80, č. 1 (2009), s. 390-399 ISSN 0039-9140 R&D Projects: GA AV ČR KAN200380801 Institutional research plan: CEZ:AV0Z50380511 Keywords : Abscisic acid * Ultra-performance liquid chromatography (UPLC) * Tandem mass spectrometry (MS/MS) Subject RIV: EC - Immunology Impact factor: 3.290, year: 2009

  1. Liquid chromatography coupled with tandem mass spectrometry for the quantitative analysis of anticancer drugs in biological matrices

    NARCIS (Netherlands)

    Stokvis, Ellen

    2004-01-01

    In this thesis, the development and validation of liquid chromatography tandem mass spectrometric (LC-MS/MS) methods for the quantitative bioanalysis of anticancer drugs are described. The monitoring of these drugs in biological fluids and tissues is important during both pre-clinical and clinical

  2. Generic solid phase extraction-liquid chromatography-tandem mass spectrometry method for fast determination of drugs in biological fluids

    NARCIS (Netherlands)

    Schellen, A.; Ooms, B.; Lagemaat, D. van de; Vreeken, R.; Dongen, W.D. van

    2003-01-01

    A generic method was developed for the fast determination of a wide range of drugs in serum or plasma. The methodology comprises generic solid-phase extraction, on-line coupled to gradient HPLC with tandem mass spectrometric detection (SPE-LC-MS/MS). The individual components of the SPE-LC-MS/MS

  3. Determination of olanzapine in whole blood using simple protein precipitation and liquid chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Marie Katrine Klose; Johansen, Sys Stybe

    2009-01-01

    A simple, sensitive, and reproducible liquid chromatography-tandem mass spectrometry method has been developed and validated for the quantification of the antipsychotic drug olanzapine in whole blood using dibenzepine as internal standard (IS). After acidic methanol-induced protein precipitation...

  4. Structure of [M + H − H2O]+ from Protonated Tetraglycine Revealed by Tandem Mass Spectrometry and IRMPD Spectroscopy

    NARCIS (Netherlands)

    Bythell, B. J.; Dain, Ryan P.; Curtice, Stephanie S.; Oomens, Jos; Steill, Jeffrey D.; Groenewold, Gary S.; la Paizs, Bé; van Stipdonk, M. J.

    2010-01-01

    Multiple-stage tandem mass spectrometry and collision-induced dissociation were used to investigate loss of H2O or CH3OH from protonated versions of GGGX (where X = G, A, and V), GGGGG, and the methyl esters of these peptides. In addition, wavelength-selective infrared multiple photon dissociation

  5. Simultaneous determination of estrogens and progestogens in honey using high performance liquid chromatography-tandem mass spectrometry

    Science.gov (United States)

    This work describes the development and validation of a method for the simultaneous determination of 13 estrogens and progestogens in honey by high performance liquid chromatography-tandem mass spectrometry. The target compounds were preconcentrated by solid phase extraction. Pretreatment variables ...

  6. Liquid chromatography-tandem mass spectrometric assay for the nucleoside reverse transcriptase inhibitor emtricitabine in human plasma

    NARCIS (Netherlands)

    Sparidans, Rolf W.; Prins, Jan M.; Schellens, Jan H. M.; Beijnen, Jos H.

    2007-01-01

    A liquid chromatography-tandem mass spectrometric assay for the determination of the antiretroviral nucleoside emtricitabine in human plasma was developed and validated using a simple sample pre-treatment procedure. After addition of 5'-deoxy-5-fluorocytidine as the internal standard and protein

  7. Determination of kava lactones in food supplements by liquid chromatography-atmospheric pressure chemical ionisation tandem mass spectrometry

    NARCIS (Netherlands)

    Bobeldijk, I.; Boonzaaijer, G.; Spies-Faber, E.J.; Vaes, W.H.J.

    2005-01-01

    Reversed-phase liquid chromatography and detection with atmospheric pressure chemical ionisation tandem mass spectrometry was used for the determination of kava extracts in herbal mixtures. One percent of kava extract can be detected, corresponding to approximately 0.05-0.2 mg/g of the individual

  8. Inborn errors of metabolism detectable by tandem mass spectrometry in Egypt: The first newborn screening pilot study.

    Science.gov (United States)

    Hassan, Fayza A; El-Mougy, Fatma; Sharaf, Sahar A; Mandour, Iman; Morgan, Marian F; Selim, Laila A; Hassan, Sawsan A; Salem, Fadia; Oraby, Azza; Girgis, Marian Y; Mahmoud, Iman G; El-Badawy, Amira; El-Nekhely, Ibrahim; Moharam, Nadia; Mehaney, Dina A; Elmonem, Mohamed A

    2016-09-01

    To estimate the burden of metabolic disorders detectable by tandem mass spectrometry in Egypt, through a pilot expanded newborn screening programme at Cairo University Children's Hospital in 2008, and examining the results of 3,900 clinically at-risk children, investigated at Cairo University Children's Hospital for the same disorders over the past 7 years using the same technology. Dried blood spots of 25,276 healthy newborns from three governorates in Upper, Middle, and Lower Egypt were screened, to give a representative sample of the Egyptian newborn population. Based on the pilot study outcomes and the results of clinically suspected children, we estimated the total birth prevalence of tandem mass spectrometry detectable metabolic disorders, and the relative frequency of several individual disorders. Among the healthy newborns, 13 metabolic disorder cases (five phenylketonuria [1:5,000], two methylmalonic acidemia, and isovaleric acidemia [1:12,500], one each of maple syrup urine disease, propionic acidemia, β-ketothiolase deficiency, and primary carnitine deficiency [1:25,000]) were confirmed, giving a total birth prevalence of 1:1944 live births. Among the clinically suspected children, 235 cases were diagnosed, representing a much wider disease spectrum. Egypt has one of the highest reported birth prevalence rates for metabolic disorders detectable by tandem mass spectrometry. Early diagnosis and management are crucial for the survival and well-being of affected children. A nationwide NBS programme by tandem mass spectrometry is recommended. © The Author(s) 2016.

  9. Determination of bovine lactoferrin in dairy products by ultra-high performance liquid chromatography–tandem mass spectrometry based on tryptic signature peptides employing an isotope-labeled winged peptide as internal standard

    International Nuclear Information System (INIS)

    Zhang, Jingshun; Lai, Shiyun; Cai, Zengxuan; Chen, Qi; Huang, Baifen; Ren, Yiping

    2014-01-01

    Highlights: • A UHPLC–MS/MS method for quantification of bovine lactoferrin was developed. • Tryptic fragment LRPVAAEIYGTK was chosen as signature peptide of bovine lactoferrin. • A winged peptide containing isotopically-labeled signature peptide was designed as internal standard. • The method for determining lactoferrin does not discriminate between the different forms of lactoferrin. • Meet the growing demand to quantify bovine lactoferrin in different dairy products. - Abstract: A new and sensitive determination method was developed for bovine lactoferrin in dairy products including infant formulas based on the signature peptide by ultra high-performance liquid chromatography and triple-quadrupole tandem mass spectrometry under the multiple reaction monitoring mode. The simple pretreatment procedures included the addition of a winged peptide containing the isotope-labeled signature peptide as internal standard, followed by an enzymatic digestion with trypsin. The signature peptide was chosen and identified from the tryptic hydrolyzates of bovine lactoferrin by ultra high-performance liquid chromatography and quadrupole-time-of-flight tandem mass spectrometry based on sequence database search. Analytes were separated on an ACQUITY UPLC BEH 300 C18 column and monitored by MS/MS in seven minutes. Quantitative result bias due to matrix effect and tryptic efficiency was corrected through the use of synthetic isotope-labeled standards. The limit of detection and limit of quantification were 0.3 mg/100 g and 1.0 mg/100 g, respectively. Bovine lactoferrin within the concentration range of 10–1000 nmol L −1 showed a strong linear relationship with a linear correlation coefficient (r) of >0.998. The intra- and inter-day precision of the method were RSD < 6.5% and RSD < 7.1%, respectively. Excellent repeatability (RSD < 6.4%) substantially supported the application of this method for the determination of bovine lactoferrin in dairy samples. The present

  10. Determination of bovine lactoferrin in dairy products by ultra-high performance liquid chromatography–tandem mass spectrometry based on tryptic signature peptides employing an isotope-labeled winged peptide as internal standard

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jingshun [Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou 310051 (China); Lai, Shiyun [Beingmate Research Institute, Beingmate Baby and Child Food Co., Ltd., Hangzhou 310007 (China); Cai, Zengxuan [Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou 310051 (China); Chen, Qi [Beingmate Research Institute, Beingmate Baby and Child Food Co., Ltd., Hangzhou 310007 (China); Huang, Baifen [Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou 310051 (China); Ren, Yiping, E-mail: renyiping@263.net [Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou 310051 (China)

    2014-06-01

    Highlights: • A UHPLC–MS/MS method for quantification of bovine lactoferrin was developed. • Tryptic fragment LRPVAAEIYGTK was chosen as signature peptide of bovine lactoferrin. • A winged peptide containing isotopically-labeled signature peptide was designed as internal standard. • The method for determining lactoferrin does not discriminate between the different forms of lactoferrin. • Meet the growing demand to quantify bovine lactoferrin in different dairy products. Abstract: A new and sensitive determination method was developed for bovine lactoferrin in dairy products including infant formulas based on the signature peptide by ultra high-performance liquid chromatography and triple-quadrupole tandem mass spectrometry under the multiple reaction monitoring mode. The simple pretreatment procedures included the addition of a winged peptide containing the isotope-labeled signature peptide as internal standard, followed by an enzymatic digestion with trypsin. The signature peptide was chosen and identified from the tryptic hydrolyzates of bovine lactoferrin by ultra high-performance liquid chromatography and quadrupole-time-of-flight tandem mass spectrometry based on sequence database search. Analytes were separated on an ACQUITY UPLC BEH 300 C18 column and monitored by MS/MS in seven minutes. Quantitative result bias due to matrix effect and tryptic efficiency was corrected through the use of synthetic isotope-labeled standards. The limit of detection and limit of quantification were 0.3 mg/100 g and 1.0 mg/100 g, respectively. Bovine lactoferrin within the concentration range of 10–1000 nmol L⁻¹ showed a strong linear relationship with a linear correlation coefficient (r) of >0.998. The intra- and inter-day precision of the method were RSD < 6.5% and RSD < 7.1%, respectively. Excellent repeatability (RSD < 6.4%) substantially supported the application of this method for the determination of bovine lactoferrin in dairy samples. The present method

  11. Experimental design for the optimization and robustness testing of a liquid chromatography tandem mass spectrometry method for the trace analysis of the potentially genotoxic 1,3-diisopropylurea.

    Science.gov (United States)

    Székely, György; Henriques, Bruno; Gil, Marco; Alvarez, Carlos

    2014-09-01

    This paper discusses a design of experiments (DoE) assisted optimization and robustness testing of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method development for the trace analysis of the potentially genotoxic 1,3-diisopropylurea (IPU) impurity in mometasone furoate glucocorticosteroid. Compared to the conventional trial-and-error method development, DoE is a cost-effective and systematic approach to system optimization by which the effects of multiple parameters and parameter interactions on a given response are considered. The LC and MS factors were studied simultaneously: flow (F), gradient (G), injection volume (Vinj), cone voltage (E(con)), and collision energy (E(col)). The optimization was carried out with respect to four responses: separation of peaks (Sep), peak area (A(p)), length of the analysis (T), and the signal-to-noise ratio (S/N). An optimization central composite face (CCF) DoE was conducted leading to the early discovery of carry-over effect which was further investigated in order to establish the maximum injectable sample load. A second DoE was conducted in order to obtain the optimal LC-MS/MS method. As part of the validation of the obtained method, its robustness was determined by conducting a fractional factorial of resolution III DoE, wherein column temperature and quadrupole resolution were considered as additional factors. The method utilizes a common Phenomenex Gemini NX C-18 HPLC analytical column with electrospray ionization and a triple quadrupole mass detector in multiple reaction monitoring (MRM) mode, resulting in short analyses with a 10-min runtime. The high sensitivity and low limit of quantification (LOQ) was achieved by (1) MRM mode (instead of single ion monitoring) and (2) avoiding the drawbacks of derivatization (incomplete reaction and time-consuming sample preparation). Quantitatively, the DoE method development strategy resulted in the robust trace analysis of IPU at 1.25 ng/mL absolute concentration

  12. Evaluating the accuracy of uranium isotope amount ratio measurements performed by a quadrupole and a multi-collector magnetic sector inductively coupled plasma mass spectrometers for nuclear safeguards

    International Nuclear Information System (INIS)

    Pereira de Oliveira, O. Jr.; Sarkis, J.E.S.; Ponzevera, E.; Alonso, A.; De Bolle, W.; Quetel, C.

    2008-01-01

    The n(U 235 )/n(U 238 ) isotope amount ratio in a set of samples was measured using two modern analytical techniques: quadrupole inductively coupled plasma mass spectrometry (ICP-QMS) and multi-collector magnetic sector inductively coupled plasma mass spectrometry (MC-ICPMS). The measured ratios were compared to the certified ratios provided by the high accuracy gas source mass spectrometry (GSMS). The components of the uncertainty were identified and their contribution to the combined standard uncertainty was estimated using the recommendations of the ISO-GUM guide. The values of the measurement uncertainty and bias were determined and then compared to the International Target Values for Measurement Uncertainties in Safeguarding Nuclear Materials. It appears that only the measurements performed by MC-ICPMS can meet the stringent requirements of international nuclear safeguards. (authors)

  13. A First Step in the Quest for the Active Constituents in Filipendula ulmaria (Meadowsweet): Comprehensive Phytochemical Identification by Liquid Chromatography Coupled to Quadrupole-Orbitrap Mass Spectrometry.

    Science.gov (United States)

    Bijttebier, Sebastiaan; Van der Auwera, Anastasia; Voorspoels, Stefan; Noten, Bart; Hermans, Nina; Pieters, Luc; Apers, Sandra

    2016-04-01

    Filipendula ulmaria (meadowsweet) is traditionally used for the treatment of inflammatory diseases and as a diuretic and antirheumatic. Extracts of Filipendulae herba are on the market in the European Union as food supplements. Nevertheless, its active constituents remain to be revealed. During this study, the phytochemical composition of Filipendulae Ulmariae Herba was comprehensively characterised for the first time with two complementary generic ultrahigh-performance liquid chromatography-photodiode array-accurate mass mass spectrometry methods. Selective ion fragmentation experiments with a hybrid quadrupole-orbital trap mass spectrometer significantly contributed to compound identification: a total of 119 compounds were tentatively identified, 69 new to F. ulmaria. A rich diversity of phenolic constituents was detected and only a few non-phenolic phytochemicals were observed. Metabolisation and pharmacological studies should be conducted to investigate which of these constituents or metabolites there of contribute to the activity of F. ulmaria after oral intake. Georg Thieme Verlag KG Stuttgart · New York.

  14. Value of tandem mass spectrometry in etiological diagnosis of cholestasis in infants

    Directory of Open Access Journals (Sweden)

    XU Lingfen

    2015-08-01

    Full Text Available Objective To investigate the value of tandem mass spectrometry (MS/MS in the etiological diagnosis of cholestasis in infants. Methods A total of 153 infants with cholestasis who visited the Department of Pediatrics, Shengjing Hospital, China Medical University, from January 2013 to March 2015 were studied. All of them underwent blood and urine examinations by MS/MS. The patients′ medical history and physical examination characteristics were recorded. Clinical examination results in biochemistry, etiology, and imageology were analyzed. Blood test and urine test were carried out by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS and gas chromatography-mass spectrometry (GC-MS, respectively. For the patients with abnormal blood or urine MS/MS results, potential pathogenic genes were determined. Comparison of continuous data was made by non-parametric Mann-Whitney U test and comparison of categorical data was made by chi-square test. Results Among the 153 infants with cholestasis, 19 (12.4% had abnormal blood or urine MS/MS results. According to clinical data and gene analysis, 15 infants among them were diagnosed with neonatal intrahepatic cholestasis caused by citrin deficiency, 2 infants with tyrosinemia, 1 infant with methioninemia, and another 1 infant with propionic acidemia. Compared with the normal MS/MS group of infants, the abnormal MS/MS group had significantly longer jaundice duration (Z=-2.227, P<0.05 and significantly higher levels of alkaline phosphatase, gamma-glutamyl transferase, and total bile acids (830.0 vs 523.0 U/L, Z=-3.185, P<0.05; 215.0 vs 160.0 U/L, Z=-2.130, P<0.05; 174.8 vs 125.7 μmol/L, Z=-2.351, P<0.05 Significant differences were also found in prothrombin time and activated partial thromboplastin time (Z=-4.300, P<0.001; Z=-3.526, P<0.001Cytomegalovirus was detected in 58.8% (90/153 of all patients and in 78.9% (15/19 of patients with abnormal MS/MS results Conclusions Given the

  15. Planetary In Situ Sample Analysis with Tandem Two-Step Laser Mass Spectrometry

    Science.gov (United States)

    Brinckerhoff, W. B.; Getty, S. A.; Cornish, T. J.; Ecelberger, S. A.; Li, X.; Merrill Floyd, M. A.; Arevalo, R.; Elsila, J.; Callahan, M. P.

    2012-12-01

    -) and organic moieties. Second, by focusing a separate "post-ionization" laser pulse just above the sample surface, we can achieve two-step laser mass spectrometry, or L2MS, in the same highly-miniaturized TOF-MS. L2MS enables selective analysis of aromatic organics even in the presence of a complex mineral matrix. Finally, by introducing an ion optical gate in the flight path, we are able to take advantage of the broad focusing capabilities of the "curved field" reflectron at the core of the TOF-MS to achieve pseudo-tandem structural analysis of selected organics. The high-speed gate is used to admit only the molecular ion/s of interest into the reflectron. Diagnostic fragments of the ion/s obtained through metastable decay or active collision-induced dissociation (CID) remain in focus despite having widely variable velocities and masses. As such even molecular isomers with differing fragmentation pathways may be distinguished through a series of pseudo-tandem mass spectra that could be obtained in an automatic process during a mission. The "real-world" benefits of these enhancements are being fully characterized using a set of synthetic and natural standard samples as well as several planetary analogs and meteorites.

  16. [Rapid determination of 8 urinary carbamate pesticides by liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Liu, Hualiang; Wang, Yuan; Zhu, Baoli

    2015-11-01

    To establish a method for simultaneously determining the urinary concentrations of 8 carbamate pesticides. After being purified by acetonitrile precipitation, urine samples were transferred to a liquid chromatography-tandem mass spectrometry system, and the concentrations of 8 carbamate pesticides were determined by external standard method. A C18 column was used for ultra-high-performance liquid chromatography; methanol/ammonium acetate solution was used as the mobile phase for gradient elution; the mass spectrometer was operated in a multi-reaction monitoring mode. The calibration curves were linear when the urinary concentrations of these carbamate pesticides were 20~800 µg/L, and the recovery rates were 61.0%~121% at spiked levels of 20, 200 and 800 µg/L, with a relative standard deviation of 1.7%~5.5%. This determination method meets the Guide for establishing occupational health standards-part 5: Determination methods of chemicals in biological materials, and can be used for simultaneous determination of 8 carbamate pesticides in the urine of poisoning patients.

  17. Absolute quantification method and validation of airborne snow crab allergen tropomyosin using tandem mass spectrometry.

    Science.gov (United States)

    Abdel Rahman, Anas M; Lopata, Andreas L; Randell, Edward W; Helleur, Robert J

    2010-11-29

    Measuring the levels of the major airborne allergens of snow crab in the workplace is very important in studying the prevalence of crab asthma in workers. Previously, snow crab tropomyosin (SCTM) was identified as the major aeroallergen in crab plants and a unique signature peptide was identified for this protein. The present study advances our knowledge on aeroallergens by developing a method of quantification of airborne SCTM by using isotope dilution mass spectrometry. Liquid chromatography tandem mass spectrometry was developed for separation and analysis of the signature peptides. The tryptic digestion conditions were optimized to accomplish complete digestion. The validity of the method was studied using international conference on harmonization protocol, Where 2-9% for CV (precision) and 101-110% for accuracy, at three different levels of quality control. Recovery of the spiked protein from PTFE and TopTip filters was measured to be 99% and 96%, respectively. To further demonstrate the applicability and the validity of the method for real samples, 45 kg of whole snow crab were processed in an enclosed (simulated) crab processing line and air samples were collected. The levels of SCTM ranged between 0.36-3.92 μg m(-3) and 1.70-2.31 μg m(-3) for butchering and cooking stations, respectively. Crown Copyright © 2010. Published by Elsevier B.V. All rights reserved.

  18. Integrated gas and liquid chromatography tandem mass spectrometry for forensic engine lubricating oil identification

    International Nuclear Information System (INIS)

    Shang, D.; McPherson, B.

    2009-01-01

    This paper presented a method for rapid chemical characterization of engine lubricating oils. Motor oils typically contain up to 5 per cent additives, such as detergent, antifoamant, dispersant, emulsifier, antioxidant, friction modifier, colour stabilizer and corrosion inhibitors. Different lube oil products usually have either different additives in various concentrations. As such, the formulation of additives in lube oil products should provide fingerprint information for forensic oil identification. The characterization method used in this study was based on a newly developed fast solvent liquid-liquid sample extraction procedure that combined the use of both liquid chromatography tandem mass spectrometry (LC-MS) and gas chromatography-mass spectrometry (GC-MS) simultaneously together with gas chromatography flame ionization detection (GC-FID). The method was used on a blind sample testing of commercially available engine lubricating products. The sample extraction procedure involved extraction of additives into acidified acetonitrile, two hexane washes of hydrophobic components of lube oil, filtration, and dilution with solvents for GC and LC analysis. The new method proved to be rapid and easy to use. It enabled the identification of unknown additives and hydrocarbons in many different types of fresh lube oils. Further tests will be needed to determine if this method can be used on real-world weathered samples. The method is part of an ongoing effort to deal with mysterious chemical spills, an important aspect of environmental protection and emergency preparedness. 8 refs., 7 figs

  19. Microfluidic platform for liquid chromatography-tandem mass spectrometry analyses of complex peptide mixtures.

    Science.gov (United States)

    Xie, Jun; Miao, Yunan; Shih, Jason; Tai, Yu-Chong; Lee, Terry D

    2005-11-01

    A microfluidic chip that integrates all the fluidic components of a gradient liquid chromatography (LC) system is described. These chips were batch-fabricated on a silicon wafer using photolithographic processes and with Parylene as the main structural material. The fabricated chip includes three electrolysis-based electrochemical pumps, one for loading the sample and the other two for delivering the solvent gradient; platinum electrodes for delivering current to the pumps and establishing the electrospray potential; a low-volume static mixer; a column packed with silica-based reversed-phase support; integrated frits for bead capture; and an electrospray nozzle. The fabricated structures were able to withstand pressures in excess of 250 psi. The device was used to perform a liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis of a mixture of peptides from the trypsin digestion of bovine serum albumen (BSA). Gradient elution through the 1.2-cm column was performed at a flow rate of 80 nL/min. Compared to the analysis of the same sample using a commercial nanoflow LC system, the chromatographic resolution was nearly as good, and the total cycle time was significantly reduced because of the minimal volume between the pumps and the column. Results demonstrate the potential of mass-produced, low-cost microfluidic systems capable of performing LC separations for proteomics applications.

  20. Redefining the Breast Cancer Exosome Proteome by Tandem Mass Tag Quantitative Proteomics and Multivariate Cluster Analysis.

    Science.gov (United States)

    Clark, David J; Fondrie, William E; Liao, Zhongping; Hanson, Phyllis I; Fulton, Amy; Mao, Li; Yang, Austin J

    2015-10-20

    Exosomes are microvesicles of endocytic origin constitutively released by multiple cell types into the extracellular environment. With evidence that exosomes can be detected in the blood of patients with various malignancies, the development of a platform that uses exosomes as a diagnostic tool has been proposed. However, it has been difficult to truly define the exosome proteome due to the challenge of discerning contaminant proteins that may be identified via mass spectrometry using various exosome enrichment strategies. To better define the exosome proteome in breast cancer, we incorporated a combination of Tandem-Mass-Tag (TMT) quantitative proteomics approach and Support Vector Machine (SVM) cluster analysis of three conditioned media derived fractions corresponding to a 10 000g cellular debris pellet, a 100 000g crude exosome pellet, and an Optiprep enriched exosome pellet. The quantitative analysis identified 2 179 proteins in all three fractions, with known exosomal cargo proteins displaying at least a 2-fold enrichment in the exosome fraction based on the TMT protein ratios. Employing SVM cluster analysis allowed for the classification 251 proteins as "true" exosomal cargo proteins. This study provides a robust and vigorous framework for the future development of using exosomes as a potential multiprotein marker phenotyping tool that could be useful in breast cancer diagnosis and monitoring disease progression.

  1. Analysis of 2-methylthio-derivatives of isoprenoid cytokinins by liquid chromatography-tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Tarkowski, Petr, E-mail: petr.tarkowski@upol.cz [Laboratory of Growth Regulators, Palacky University and Institute of Experimental Botany ASCR, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Department of Biochemistry, Faculty of Science, Palacky University, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Vaclavikova, Katerina, E-mail: katka.vaclavik@seznam.cz [Laboratory of Growth Regulators, Palacky University and Institute of Experimental Botany ASCR, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Department of Biochemistry, Faculty of Science, Palacky University, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Novak, Ondrej, E-mail: ondrej.novak@upol.cz [Laboratory of Growth Regulators, Palacky University and Institute of Experimental Botany ASCR, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Pertry, Ine, E-mail: ine.pertry@ugent.BE [Department of Plant Biotechnology and Genetics, Ghent University, K.L.Ledeganckstraat 35, B-9000 Gent (Belgium); Hanus, Jan, E-mail: helehan@seznam.cz [Isotope Laboratory, Institute of Experimental Botany ASCR, Videnska 1083, 142 20 Prague (Czech Republic); Whenham, Robert [Apex Organics, Devon, England (United Kingdom); Vereecke, Danny, E-mail: danny.vereecke@hogent.BE [Department of Plant Production, University College Ghent, Ghent University, Schoonmeersstraat 52, B-9000 Gent (Belgium); Sebela, Marek, E-mail: marek.sebela@upol.cz [Department of Biochemistry, Faculty of Science, Palacky University, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Strnad, Miroslav, E-mail: miroslav.strnad@upol.cz [Laboratory of Growth Regulators, Palacky University and Institute of Experimental Botany ASCR, Slechtitelu 11, 783 71 Olomouc (Czech Republic)

    2010-11-08

    A sensitive and reliable high-performance liquid chromatographic method with tandem mass spectrometric detection has been developed and used for the determination of 2-methylthio-cytokinin derivatives produced by the phytopathogenic actinomycete Rhodococcus fascians. The cultivation medium containing secreted cytokinins was concentrated and subjected to a solid-phase extraction (C18 and ion-exchange). The purified samples were further separated and analyzed by HPLC-ESI-MS/MS. This allowed to achieve chromatographic resolution of six highly hydrophobic cytokinin species including 2-methylthio-isopentenyladenine, 2-methylthio-isopentenyladenosine, 2-methylthio-trans-zeatin and 2-methylthio-trans-zeatin riboside and their cis-isomers when a reversed-phase chromatographic column (C4) and a mobile phase consisting of acetonitrile and 20 mM ammonium formate, pH 5, were used. Quantification was performed by a standard isotope dilution method using a multiple-reaction monitoring (MRM) mode. In the MRM mode, limits of detection reached 20-30 fmol and linear ranges spanned four orders of magnitude. Recovery values were between 35% and 65% and the analytical accuracy between 95% and 149%. The proposed bioanalytical method, which takes advantage of effective chromatographic separation of six 2-methyltio-derivatives (including isomers of zeatin-type cytokinins) and sensitive mass spectrometric detection, may become useful for plant biologists studying the significance of these substances in plant-microbe interactions.

  2. Determination of synthetic dyes in bean and meat products by liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Li, Juan; Ding, Xiaoming; Zheng, Jiaxin; Liu, Dandan; Guo, Fei; Liu, Hongmin; Zhang, Yanbing

    2014-09-01

    A sensitive and efficient method was developed for the simultaneous determination of eight synthetic dyes (Chrysoidin, Auramine O, Sudan(I-IV), Para Red, and Rhodamine B) in bean and meat products using high-performance liquid chromatography with tandem mass spectrometry. A simple extraction procedure using acetonitrile has been applied for the extraction of these dyes from spiked bean and meat samples. Chromatographic separation was achieved on a Waters XTerra C18 column (2.1 × 150 mm, 5 μm) with a multistep gradient elution. Detection and quantification were performed using mass spectrometry in multiple reaction monitoring mode. Linear calibrations were obtained with correlation coefficients R(2) > 0.99. The limits of detection and quantification for the eight dyes were in the ranges of 0.03-0.75 and 0.1-2.0 μg/kg depending on matrices, respectively. The recoveries of these dyes in different food matrices were between 71.2 and 116.9% with relative standard deviations dyes at trace levels in bean and meat products. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Accelerator mass spectrometry of the heaviest long-lived radionuclides with a 3-MV tandem accelerator

    Science.gov (United States)

    Vockenhuber, Christof; Golser, Robin; Kutschera, Walter; Priller, Alfred; Steier, Peter; Winkler, Stephan; Liechtenstein, Vitaly

    2002-12-01

    A 3-MV pelletron tandem accelerator is the heart of the Vienna environmental research accelerator (VERA). The original design of the beam transport components allows the transport of ions of all elements, from the lightest to the heaviest. For light ions the suppression of neighboring masses was sufficient to measure isotopic ratios of {(14}) C/{(12}) C and {(26}) Al/{(27}) Al as low as 10{(-15}) and {(10}) Be/{(9}) Be down to 10{(-13}) . To suppress neighboring masses for the heaviest radionuclides in the energy range of 10-20 MeV, the resolution of VERA was increased both by improving the ion optics of existing elements at the injection side and by installing a new high-resolution electrostatic separator at the high-energy side. Interfering ions which pass all beam filters are identified with a Bragg-type ionization detector and a high-resolution time-of-flight system. Two ultra-thin diamond-like carbon (DLC) foils are used in the start and stop detector, which substantially reduces losses due to beam straggling. This improved set up enables us to measure even the heaviest long-lived radionuclides, where stable isobaric interferences are absent (e.g. {(236}) U and {(244}) Pu), down to environmental levels. Moreover, the advantage of a `small' and well manageable machine like VERA lies in its higher stability and reliability which allows to measure these heavy radionuclides more accurately, and also a large number of samples.

  4. Liquid chromatography-tandem mass spectrometry for analysis of intestinal permeability of loperamide in physiological buffer.

    Directory of Open Access Journals (Sweden)

    Miriam S Rubelt

    Full Text Available Analysis of in vitro samples with high salt concentrations represents a major challenge for fast and specific quantification with liquid chromatography-tandem mass spectrometry (LC-MS/MS. To investigate the intestinal permeability of opioids in vitro employing the Ussing chamber technique, we developed and validated a fast, sensitive and selective method based on LC-MS/MS for the determination of loperamide in HEPES-buffered Ringer's solution. Chromatographic separation was achieved with an Atlantis dC18 column, 2.1 mm×20 mm, 3 µm particle size and a gradient consisting of methanol/0.1% formic acid and ammonium acetate. The flow rate was 0.7 ml/min, and the total run time was 3 min. For quantification, two mass transitions for loperamide and a deuterated internal standard (methadone-d(3 were used. The lower limit of loperamide quantification was 0.2 ng/ml. This new LC-MS/MS method can be used for the detection of loperamide in any experimental setup using HEPES-buffered Ringer's solution as a matrix compound.

  5. Dynamic Bayesian Network for Accurate Detection of Peptides from Tandem Mass Spectra.

    Science.gov (United States)

    Halloran, John T; Bilmes, Jeff A; Noble, William S

    2016-08-05

    A central problem in mass spectrometry analysis involves identifying, for each observed tandem mass spectrum, the corresponding generating peptide. We present a dynamic Bayesian network (DBN) toolkit that addresses this problem by using a machine learning approach. At the heart of this toolkit is a DBN for Rapid Identification (DRIP), which can be trained from collections of high-confidence peptide-spectrum matches (PSMs). DRIP's score function considers fragment ion matches using Gaussians rather than fixed fragment-ion tolerances and also finds the optimal alignment between the theoretical and observed spectrum by considering all possible alignments, up to a threshold that is controlled using a beam-pruning algorithm. This function not only yields state-of-the art database search accuracy but also can be used to generate features that significantly boost the performance of the Percolator postprocessor. The DRIP software is built upon a general purpose DBN toolkit (GMTK), thereby allowing a wide variety of options for user-specific inference tasks as well as facilitating easy modifications to the DRIP model in future work. DRIP is implemented in Python and C++ and is available under Apache license at http://melodi-lab.github.io/dripToolkit .

  6. Analysis of 2-methylthio-derivatives of isoprenoid cytokinins by liquid chromatography-tandem mass spectrometry

    International Nuclear Information System (INIS)

    Tarkowski, Petr; Vaclavikova, Katerina; Novak, Ondrej; Pertry, Ine; Hanus, Jan; Whenham, Robert; Vereecke, Danny; Sebela, Marek; Strnad, Miroslav

    2010-01-01

    A sensitive and reliable high-performance liquid chromatographic method with tandem mass spectrometric detection has been developed and used for the determination of 2-methylthio-cytokinin derivatives produced by the phytopathogenic actinomycete Rhodococcus fascians. The cultivation medium containing secreted cytokinins was concentrated and subjected to a solid-phase extraction (C18 and ion-exchange). The purified samples were further separated and analyzed by HPLC-ESI-MS/MS. This allowed to achieve chromatographic resolution of six highly hydrophobic cytokinin species including 2-methylthio-isopentenyladenine, 2-methylthio-isopentenyladenosine, 2-methylthio-trans-zeatin and 2-methylthio-trans-zeatin riboside and their cis-isomers when a reversed-phase chromatographic column (C4) and a mobile phase consisting of acetonitrile and 20 mM ammonium formate, pH 5, were used. Quantification was performed by a standard isotope dilution method using a multiple-reaction monitoring (MRM) mode. In the MRM mode, limits of detection reached 20-30 fmol and linear ranges spanned four orders of magnitude. Recovery values were between 35% and 65% and the analytical accuracy between 95% and 149%. The proposed bioanalytical method, which takes advantage of effective chromatographic separation of six 2-methyltio-derivatives (including isomers of zeatin-type cytokinins) and sensitive mass spectrometric detection, may become useful for plant biologists studying the significance of these substances in plant-microbe interactions.

  7. Use of liquid chromatography hybrid triple-quadrupole mass spectrometry for the detection of emodin metabolites in rat bile and urine.

    Science.gov (United States)

    Wu, Songyan; Zhang, Yaqing; Zhang, Zunjian; Song, Rui

    2017-10-01

    Emodin is the representative form of rhubarb, which is widely used in traditional Chinese medicine for the treatment of purgative, anti-inflammatory, antioxidative and antiviral, etc. Previous reports demonstrated that emodin glucuronide was the major metabolite in plasma. Owing to the extensive conjugation reactions of polyphenols, the aim of this study was to identify the metabolites of emodin in rat bile and urine. Neutral loss and precursor ion scan methods of triple-quadrupole mass spectrometer revealed 13 conjugated metabolites in rat bile and 22 metabolites in rat urine, which included four phase I and 18 phase II metabolites. The major metabolites in rat biosamples were emodin glucuronoconjugates. Moreover, rhein monoglucuronide, chrysophanol monoglucuronide and rhein sulfate were proposed for the first time after oral administration of emodin. Overall, liquid chromatography hybrid triple-quadrupole mass spectrometry analysis leads to the discovery of several novel emodin metabolites in rat bile and urine and underscores that conjugated with glucuronic acid is the main metabolic pathway. Copyright © 2017 John Wiley & Sons, Ltd.

  8. Qualitative and quantitative determination of YiXinShu Tablet using ultra high performance liquid chromatography with Q Exactive hybrid quadrupole orbitrap high-resolution accurate mass spectrometry.

    Science.gov (United States)

    Sun, Zhi; Li, Zhuolun; Zuo, Lihua; Wang, Zhenhui; Zhou, Lin; Shi, Yingying; Kang, Jian; Zhu, Zhenfeng; Zhang, Xiaojian

    2017-11-01

    To clarify and quantify the chemical profile of YiXinShu Tablet rapidly, a feasible and accurate strategy was developed by applying ultra high performance liquid chromatography with Q Exactive hybrid quadrupole orbitrap high-resolution accurate mass spectrometry. A total of 105 components were identified, including 25 phenanthraquinones, 11 lactones, 19 lignans, 24 acids, and 26 other compounds. Among them, 26 major compounds were unambiguously detected by comparing with reference standards. And 19 of these compounds in three batches of YiXinShu Tablet were selected for quantitative determination. (Z)-Ligustilide, salvianic acid A, salvianolic acid A, salvianolic acid B, and rosmarinic acid were abundant in these three batches with contents over 1 mg/g. The established analysis methods were examined to be accurate and feasible. The results show that the ultra high performance liquid chromatography with Q Exactive hybrid quadrupole orbitrap high-resolution accurate mass spectrometry method has a powerful qualitative ability and promising quantitative application. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Proposal for the award of a contract for the supply of the main superconducting quadrupoles and assembly of the cold masses of the LHC short straight sections

    CERN Document Server

    2000-01-01

    This document concerns the award of a contract for the supply of the main superconducting quadrupoles and assembly of the cold masses of the LHC Short Straight Sections. Following a market survey carried out among 21 firms in ten Member States and one firm in Japan, a call for tenders (IT-2455/LHC/LHC) was sent on 21 October 1999 to six firms and one consortium consisting of two firms in five Member States. By the closing date, CERN had received six tenders. The Finance Committee is invited to agree to the negotiation of a contract with the firm ACCEL INSTRUMENTS (DE), the lowest bidder, for the supply of the main superconducting quadrupoles and the assembly of the cold masses of the LHC Short Straight Sections for a total amount of 60 209 516 Deutschmarks (49 458 600 Swiss francs), subject to revision for contractual deliveries after 31 December 2001. The above amount in Swiss francs has been calculated using the rate of exchange stipulated in the tender. The firm ACCEL INSTRUMENTS has declared the following...

  10. Sensitive and convenient method for the quantification of clonidine in serum of pediatric patients using liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Müller, C; Ramic, M; Harlfinger, S; Hünseler, C; Theisohn, M; Roth, B

    2007-01-19

    An improved and easy to use liquid chromatography/tandem mass spectrometric (LC/MS/MS) method in human serum was developed for the quantification of clonidine (CLD), an alpha2-/alpha1-adrenoceptor agonist, used for analgo-sedation and the therapy of opioid withdrawal in pediatric patients. Sample preparation consisted of precipitation of serum proteins by adding acetonitrile and centrifugation of the sample subsequently. [(2)H4]Clonidine (CLD4) served as internal standard. Chromatographic separation of the supernatant was achieved using a 100mmx3mm, 5microm Thermo Electron BetaBasic C4 column with isocratic flow and elution consisting of 0.1% formic acid/acetonitrile (85/15, v/v) and a flow-rate of 350microl/min resulting in a column pressure of 280-420kPa. LC/MS/MS detection was performed by using a triple-stage quadrupole mass spectrometer (TSQ Quantum, Thermo Electron) working in selected reaction monitoring mode with positive electrospray ionization. The analyte was quantified in a single run within 5min. Linearity was demonstrated over the expected concentration range 0.15-50microg/l CLD. The lower limit of quantification (LLOQ) and the limit of detection were 0.1microg/l and 0.01microg/l, respectively. None of the drugs used concomitantly during analgesic therapy interfered in the assay in vitro. Intra-day precision expressed as RSD was 9.6% or less for CLD, while inter-day result was 10.0% or less for CLD. Intra-day and inter-day accuracy was within +/-4.9% and +/-1.8%, respectively. The method was validated according to the international guidelines of the International Conference on Harmonisation (ICH) and the US Food and Drugs Administration (FDA). The described method is suitable to analyse serum samples with very small volumes and sets the stage for pharmacokinetic studies in pediatric studies.

  11. A liquid chromatography-tandem mass spectrometric method for quantitative determination of native 5-methyltetrahydrofolate and its polyglutamyl derivatives in raw vegetables.

    Science.gov (United States)

    Wang, Chao; Riedl, Ken M; Schwartz, Steven J

    2010-11-01

    Folate deficiency is a prevalent phenomenon worldwide especially in underprivileged countries. Polyglutamyl 5-methyltetrahydrofolate (5MTHF) species are the naturally occurring principle folate in store-bought vegetables. Here we report a simple and complete extraction method for the determination of native polyglutamyl 5-methyltetrahydrofolate in vegetables using high performance liquid chromatography with tandem mass spectrometric detection (HPLC-MS/MS). Coarsely chopped samples (18 different vegetables) were steamed to inactivate glutamylase enzymes and liberate folate from binding proteins and extracted in a reducing buffer with (13)C(5) 5MTHF stable isotope added as internal standard. The polyglutamyl 5-methyltetrahydrofolate species were separated in 9 min on a C(18) column using a reversed phase system. HPLC eluate was interfaced with a triple quadrupole mass spectrometer operated in electrospray positive mode. The respective pseudomolecular cation of each polyglutamyl 5-methyltetrahydrofolate species was selected for fragmentation to a common daughter ion for detection. We quantitated polyglutamyl 5-methyltetrahydrofolate in store-bought vegetables from families Brassicaceae, Asteraceae and Amaranthaceae (including mustard greens, romaine lettuce and Swiss chard) of which most have not been quantitated previously. Most vegetables from Asteraceae and those from Amaranthaceae contained similar amounts of monoglutamyl 5MTHF and polyglutamyl 5MTHF while Brassicaceae were dominated by polyglutamyls and endive species (Asteraceae) contained mainly monoglutamyl 5MTHF. The precision of the method for the various polyglutamyl 5-methyltetrahydrofolate forms was 1-9% RSD, recovery 84-91%, limit of detection 64-658 fmol and limit of quantitation 193-1994 fmol. Herein we describe a rapid, sensitive and selective HPLC-MS/MS technique to quantitate polyglutamyl 5-methyltetrahydrofolate species. This method may be suitable for analyzing the polyglutamyl 5

  12. A liquid chromatography–tandem mass spectrometric method for quantitative determination of native 5-methyltetrahydrofolate and its polyglutamyl derivatives in raw vegetables

    Science.gov (United States)

    Wang, Chao; Riedl, Ken M.; Schwartz, Steven J.

    2013-01-01

    Folate deficiency is a prevalent phenomenon worldwide especially in underprivileged countries. Polyglutamyl 5-methyltetrahydrofolate (5MTHF) species are the naturally occurring principle folate in store-bought vegetables. Here we report a simple and complete extraction method for the determination of native polyglutamyl 5-methyltetrahydrofolate in vegetables using high performance liquid chromatography with tandem mass spectrometric detection (HPLC–MS/MS). Coarsely chopped samples (18 different vegetables) were steamed to inactivate glutamylase enzymes and liberate folate from binding proteins and extracted in a reducing buffer with 13C5 5MTHF stable isotope added as internal standard. The polyglutamyl 5-methyltetrahydrofolate species were separated in 9 min on a C18 column using a reversed phase system. HPLC eluate was interfaced with a triple quadrupole mass spectrometer operated in electrospray positive mode. The respective pseudomolecular cation of each polyglutamyl 5-methyltetrahydrofolate species was selected for fragmentation to a common daughter ion for detection. We quantitated polyglutamyl 5-methyltetrahydrofolate in store-bought vegetables from families Brassicaceae, Asteraceae and Amaranthaceae (including mustard greens, romaine lettuce and Swiss chard) of which most have not been quantitated previously. Most vegetables from Asteraceae and those from Amaranthaceae contained similar amounts of monoglutamyl 5MTHF and polyglutamyl 5MTHF while Brassicaceae were dominated by polyglutamyls and endive species (Asteraceae) contained mainly monoglutamyl 5MTHF. The precision of the method for the various polyglutamyl 5-methyltetrahydrofolate forms was 1–9% RSD, recovery 84–91%, limit of detection 64–658 fmol and limit of quantitation 193–1994 fmol. Herein we describe a rapid, sensitive and selective HPLC–MS/MS technique to quantitate polyglutamyl 5-methyltetrahydrofolate species. This method may be suitable for analyzing the polyglutamyl 5

  13. A novel liquid chromatography/tandem mass spectrometry method for the quantification of glycine as biomarker in brain microdialysis and cerebrospinal fluid samples within 5min.

    Science.gov (United States)

    Voehringer, Patrizia; Fuertig, René; Ferger, Boris

    2013-11-15

    Glycine is an important amino acid neurotransmitter in the central nervous system (CNS) and a useful biomarker to indicate biological activity of drugs such as glycine reuptake inhibitors (GRI) in the brain. Here, we report how a liquid chromatography/tandem mass spectrometry (LC-MS/MS) method for the fast and reliable analysis of glycine in brain microdialysates and cerebrospinal fluid (CSF) samples has been established. Additionally, we compare this method with the conventional approach of high performance liquid chromatography (HPLC) coupled to fluorescence detection (FD). The present LC-MS/MS method did not require any derivatisation step. Fifteen microliters of sample were injected for analysis. Glycine was detected by a triple quadrupole mass spectrometer in the positive electrospray ionisation (ESI) mode. The total running time was 5min. The limit of quantitation (LOQ) was determined as 100nM, while linearity was given in the range from 100nM to 100μM. In order to demonstrate the feasibility of the LC-MS/MS method, we measured glycine levels in striatal in vivo microdialysates and CSF of rats after administration of the commercially available glycine transporter 1 (GlyT1) inhibitor LY 2365109 (10mg/kg, p.o.). LY 2365109 produced 2-fold and 3-fold elevated glycine concentrations from 1.52μM to 3.6μM in striatal microdialysates and from 10.38μM to 36μM in CSF, respectively. In conclusion, we established a fast and reliable LC-MS/MS method, which can be used for the quantification of glycine in brain microdialysis and CSF samples in biomarker studies. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Simultaneous determination of morinidazole, its N-oxide, sulfate, and diastereoisomeric N(+)-glucuronides in human plasma by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Gao, Ruina; Zhong, Dafang; Liu, Ke; Xia, Yu; Shi, Rongwei; Li, Hua; Chen, Xiaoyan

    2012-11-01

    Morinidazole is a new third-generation 5-nitroimidazole antimicrobial drug. To investigate the pharmacokinetic profiles of morinidazole and its major metabolites in humans, a liquid chromatography-tandem mass spectrometry method was developed and validated for simultaneous determination of morinidazole, its N-oxide metabolite (M4-1), a sulfate conjugate (M7), and two diastereoisomeric N(+)-glucuronides (M8-1 and M8-2) in human plasma. A simple acetonitrile-induced protein precipitation was employed to extract five analytes and internal standard metronidazole from 50μL human plasma. To avoid the interference from the in-source dissociation of the sulfate and achieve the baseline-separation of diastereoisomeric N(+)-glucuronides, all the analytes were separated from each other with the mobile phase consisting of 10mM ammonium formate and acetonitrile using gradient elution on a Hydro-RP C(18) column (50mm×2mm, 4μm) with a total run time of 5min. The API 4000 triple quadrupole mass spectrometer was operated under the multiple reaction-monitoring mode using the electrospray ionization technique. The developed method was linear in the concentration ranges of 10.0-12,000ng/mL for morinidazole, 1.00-200ng/mL for M4-1, 2.50-500ng/mL for M7, 3.00-600ng/mL for M8-1, and 10.0-3000ng/mL for M8-2. The intra- and inter-day precisions for each analyte met the accepted value. Results of the stability of morinidazole and its metabolites in human plasma were also presented. The method was successfully applied to the clinical pharmacokinetic studies of morinidazole injection in healthy subjects, patients with moderate hepatic insufficiency, and patients with severe renal insufficiency, respectively. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Potential of atmospheric pressure chemical ionization source in gas chromatography tandem mass spectrometry for the screening of urinary exogenous androgenic anabolic steroids.

    Science.gov (United States)

    Raro, M; Portolés, T; Pitarch, E; Sancho, J V; Hernández, F; Garrostas, L; Marcos, J; Ventura, R; Segura, J; Pozo, O J

    2016-02-04

    The atmospheric pressure chemical ionization (APCI) source for gas chromatography-mass spectrometry analysis has been evaluated for the screening of 16 exogenous androgenic anabolic steroids (AAS) in urine. The sample treatment is based on the strategy currently applied in doping control laboratories i.e. enzymatic hydrolysis, liquid-liquid extraction (LLE) and derivatization to form the trimethylsilyl ether-trimethylsilyl enol ether (TMS) derivatives. These TMS derivatives are then analyzed by gas chromatography tandem mass spectrometry using a triple quadrupole instrument (GC-QqQ MS/MS) under selected reaction monitoring (SRM) mode. The APCI promotes soft ionization with very little fragmentation resulting, in most cases, in abundant [M + H](+) or [M + H-2TMSOH](+) ions, which can be chosen as precursor ions for the SRM transitions, improving in this way the selectivity and sensitivity of the method. Specificity of the transitions is also of great relevance, as the presence of endogenous compounds can affect the measurements when using the most abundant ions. The method has been qualitatively validated by spiking six different urine samples at two concentration levels each. Precision was generally satisfactory with RSD values below 25 and 15% at the low and high concentration level, respectively. Most the limits of detection (LOD) were below 0.5 ng mL(-1). Validation results were compared with the commonly used method based on the electron ionization (EI) source. EI analysis was found to be slightly more repeatable whereas lower LODs were found for APCI. In addition, the applicability of the developed method has been tested in samples collected after the administration of 4-chloromethandienone. The highest sensitivity of the APCI method for this compound, allowed to increase the period in which its administration can be detected. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Analysis of 17 neurotransmitters, metabolites and precursors in zebrafish through the life cycle using ultrahigh performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Santos-Fandila, A; Vázquez, E; Barranco, A; Zafra-Gómez, A; Navalón, A; Rueda, R; Ramírez, M

    2015-09-15

    An ultrahigh performance liquid chromatography-tandem mass spectrometry method for the identification and quantification of neurotransmitters, metabolites and precursors at different stages in zebrafish life was developed. Betaine, glutamine, glutamic acid, γ-aminobutyric acid, phosphocholine, glycerophosphocholine, cytidine 5'-diphosphocholine, choline, acetylcholine, dopamine, norepinephrine, serotonin, tyrosine, epinephrine, tryptophan, 5-hydroxyindolacetic acid and agmatine were selected as analytes. The method consisted of a simple deproteinization of samples using methanol and formic acid, subsequent injection onto the chromatographic equipment and quantification with a triple quadrupole mass spectrometer detector using an electrospray ionization interface in positive mode. Limits of detection ranged from 0.02 to 11ngmL(-1) and limits of quantification from 0.1 to 38ngmL(-1), depending on the analyte. The method was validated according to US Food and Drugs Administration (FDA) guideline for bioanalytical assays. Precision, expressed as relative standard deviation (%RSD), was lower than 15% in all cases, and the determination coefficient (R(2)) was equal or higher than 99.0% with a residual deviation for each calibration point lower than ±25%. Mean recoveries were between 85% and 115%. The method was applied to determine of these compounds in zebrafish from early stages of development to adulthood and showed the time-course of neurotransmitters and others neurocompounds through the life cycle. The possibility of measuring up to 17 compounds related with the main neurotransmitter systems in a simple analytical method will complement and reinforce the use of zebrafish in multiple applications in the field of neurosciences. The proposed method will facilitate future studies related with brain development. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. A liquid chromatography with tandem mass spectrometry method for simultaneous determination of UTL-5g and its metabolites in human plasma.

    Science.gov (United States)

    Shaw, Jiajiu; Wiegand, Richard; Wu, Jianmei; Bao, Xun; Valeriote, Frederick; Li, Jing

    2015-06-01

    UTL-5g is a novel small-molecule TNF-α inhibitor under investigation as both a chemoprotective and radioprotective agent. Animal studies showed that pretreatment of UTL-5g protected kidney, liver, and platelets from cisplatin-induced toxicity. In addition, UTL-5g reduced liver and lung injuries induced by radiation in vivo. Although a number of preclinical studies have been conducted, a validated bioanalytical method for UTL-5g in human plasma has not been published. In this work, a sensitive and reproducible reverse-phase liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) assay was developed and validated for the determination of UTL-5g and its metabolites, 5-methylisoxazole-3-carboxylic acid (ISOX) and 2,4-dichloroaniline (DCA), in human plasma. The method involves a simple methanol precipitation step followed by injection of the supernatant onto a Waters 2695 HPLC system coupled with a Waters Quattro Micro™ triple quadrupole mass spectrometer. Chromatographic separation was accomplished using a Waters Nova-Pak C18 column maintained at 30°C, running at gradient mode with mobile phase consisting of 0.1% formic acid in water and 0.1% formic acid in methanol at a flow rate of 0.2mL/min. The analytes were monitored under positive electrospray ionization (ESI). Quantitation of these compounds in plasma was linear from 0.05 to 10μM. The lower limit of quantitation (LLOQ) was 0.05, 0.1, and 0.2μM for UTL-5g, ISOX and DCA, respectively. The accuracy and intra-and inter-day precisions were within the generally accepted criteria for bioanalytical method (5g and its metabolites, ISOX and DCA. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. High-throughput determination of cortisol, cortisone, and melatonin in oral fluid by on-line turbulent flow liquid chromatography interfaced with liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Fustinoni, Silvia; Polledri, Elisa; Mercadante, Rosa

    2013-07-15

    Cortisol, cortisone, and melatonin (CORTol, CORTone, and MELA, respectively) are hormones related to stress and sleep disorders. Their detection is relevant to epidemiological studies aimed at investigating the effects of circadian cycle disruption. The aim of this study was to develop and evaluate a high-throughput assay for the detection of CORTol, CORTone, and MELA concentrations in non-invasively collected oral fluid samples. A liquid chromatography/tandem mass spectrometry (LC/MS/MS) method to measure levels of CORTol, CORTone, and MELA in oral fluid samples in the presence of deuterated analogs was optimized and validated. A 50 μL aliquot of oral fluid sample, obtained by centrifugation of a chewed swab, was purified using on-line turbulent flow liquid chromatography. Analytes were then separated using C18 reversed-phase chromatography, subjected to positive ionization using an electrospray source, then quantitated using a triple quadrupole mass detector in the selected reaction monitoring mode. Limits of quantification and linear dynamic ranges were found to be 0.55 nmol/L, 5.5 nmol/L, and 0.004 nmol/L, and up to 28 nmol/L, 277 nmol/L, and 0.43 nmol/L for CORTol, CORTone, and MELA, respectively. Inter- and intra-run precisions as relative standard deviation values were <5%, and accuracies were within 95-106% of theoretical concentrations. An evaluation of matrix effects showed that the use of deuterated analogs controlled sources of bias. Furthermore, the total analysis time per sample was 13 min, resulting in a throughput of approximately 100 samples/day. To our knowledge, this is the first automated, high-throughput assay for the simultaneous quantification of CORTol, CORTone, and MELA in oral fluid specimens. Copyright © 2013 John Wiley & Sons, Ltd.

  19. Development and validation of an assay for the simultaneous determination of zidovudine, abacavir, emtricitabine, lamivudine, tenofovir and ribavirin in human plasma using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Kromdijk, W; Pereira, S A; Rosing, H; Mulder, J W; Beijnen, J H; Huitema, A D R

    2013-03-01

    This paper describes the development and validation of an assay for the simultaneous quantification of the antiviral and antiretroviral drugs zidovudine, abacavir, emtricitabine, lamivudine, tenofovir and ribavirin in human plasma using liquid chromatography coupled to tandem mass spectrometry. Sample pretreatment consisted of protein precipitation with 0.1% (v/v) formic acid in methanol, evaporation and reconstitution. Chromatographic separation was performed on a Synergy Polar reversed phase C18 column (150 mm × 2.0 mm ID, particle size 4 μm) using a stepwise gradient with 0.1% (v/v) formic acid in water and 0.1% (v/v) formic acid in methanol at a flow rate of 300 μL/min. A triple quadrupole mass spectrometer operating in the positive ionization mode was used for drug detection and quantification. Isotopically labeled zidovudine, lamivudine, tenofovir and ribavirin were used as internal standards. The method was validated over a clinical range of 20-2500 ng/mL for zidovudine, lamivudine and tenofovir, 4-500 ng/mL for abacavir and emtricitabine and 160-20,000 ng/mL for ribavirin. The inter and intra-assay accuracies and precisions were between -8.47% and 14.2% for zidovudine, emtricitabine and ribavirin. For abacavir, lamivudine and tenofovir, the inter and intra-assay accuracies and precisions at the lower limit of quantification were between -11.0% and 18.3%, whereas at all other levels these accuracies and precisions were between -11.7% and 12.0%. The described method is suitable for the determination of zidovudine, abacavir, emtricitabine, lamivudine, tenofovir and ribavirin in human plasma in clinical practice to monitor plasma concentrations in selected cases to optimize therapy. Copyright © 2013. Published by Elsevier B.V.

  20. Sorption of Aldrich humic acid onto hematite: Insights into fractionation phenomena by electro-spray ionization with quadrupole time-of-flight mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Reiller, Pascal; Amekraz, Badia; Moulin, Christophe [CEA, CE Saclay, Nuclear Energy Division, DANS/DPC/SECR, Laboratoire de Speciation des Radionucleides et des Molecules, Batiment 391, BP 11, F-91191 Gif sur Yvette Cedex (France)

    2006-07-01

    Sorption induced fractionation of purified Aldrich humic acid (PAHA) on hematite is studied through the modification of electro-spray ionization (ESI) quadrupole time-of-flight (QToF) mass spectra of supernatants from retention experiments. The ESI mass spectra show an increase of the 'mean molecular masses' of the molecules that constitutes humic aggregates. The low molecular weight fraction (LMWF; m/z {<=} 600 Da) is preferentially sorbed compared to two other fractions. The resolution provided by ESI-QToF mass spectrometer in the low-mass range provided evidence of further fractionation induced by sorption within the LMWF. Among the two latter fractions, the high molecular weight fraction (HMWF; m/z {approx_equal} 1700 Da) seems to be more prone to sorption compared to the intermediate molecular weight fraction (IMWF; m/z {approx_equal} 900 Da). The IMWF seems to be more hydrophilic as it should be richer in O, N, and alkyl C from the proportion of even mass, and poorer in aromatic structures from mass defect analysis in ESI mass spectra. (authors)

  1. Analysis of perfluoroalkyl substances in cord blood by turbulent flow chromatography coupled to tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Llorca, Marta; Perez, Francisca [Department of Environmental Chemistry, IDAEA-CSIC, Barcelona (Spain); Farre, Marinella, E-mail: mfuqam@cid.csic.es [Department of Environmental Chemistry, IDAEA-CSIC, Barcelona (Spain); Agramunt, Silvia [Centre for Research in Environmental Epidemiology (CREAL), Barcelona (Spain); IMIM (Hospital del Mar Research Institute), Barcelona (Spain); Kogevinas, Manolis [Centre for Research in Environmental Epidemiology (CREAL), Barcelona (Spain); IMIM (Hospital del Mar Research Institute), Barcelona (Spain); CIBER Epidemiologia y Salud Publica (CIBERESP), Barcelona (Spain); National School of Public Health, Athens (Greece); Barcelo, Damia [Department of Environmental Chemistry, IDAEA-CSIC, Barcelona (Spain); Catalan Institute for Water Research (ICRA), Girona (Spain); King Saud University, Riyadh (Saudi Arabia)

    2012-09-01

    A fast on-line analytical method based on turbulent flow chromatography (TFC) in combination with tandem mass spectrometry has been applied for the first time for the analysis of eighteen perfluoroalkyl substances (PFASs), in cord blood. A simple and rapid sample pre-treatment was optimised consisting on protein precipitation of 100 {mu}L of sample with acetonitrile (1:1) followed by centrifugation during 10 min. The method was adapted to be sensitive enough and robust with minimum sample injection volume requirements (20 {mu}L). The optimised methodology presented method limits of detection (MLOD) between 0.031 and 0.76 {mu}g/L, detection capabilities (CC{alpha}) in the range between 0.005 and 0.99 {mu}g/L and decision limits (CC{beta}) ranging from 0.006 to 1.16 {mu}g/L. The recoveries in blank blood were calculated by spiking experiments with a mixture of 18 PFASs and established between 70 and 126% for most of compounds. Isotopic dilution was carried out for quantification of selected analytes. In-house validation of this new approach was carried out according to the requirements in the 2002/657/EC Decision. Finally the good applicability of this new approach was proved by the analysis of 60 cord blood samples from two different Mediterranean cities, Barcelona (Spain) and Heraklion (Greece). Ions perfluorohexanesulfonate (PFHxS) and perfluorooctanesulfonate (PFOS) were found at highest concentration and the more frequently compounds were PFHxS, PFOS and perfluorooctanoic acid (PFOA). The newly developed method proved to be suitable for large-scale epidemiologic studies, and to the data on PFASs exposure during pregnancy. -- Highlights: Black-Right-Pointing-Pointer An on-line method has been developed for the analysis of 18 perfluoroalkyl substances. Black-Right-Pointing-Pointer The method is based on turbulent flow chromatography tandem mass spectrometry. Black-Right-Pointing-Pointer The method was applied in 60 cord blood samples from 2 Mediterranean cities

  2. Analysis of perfluoroalkyl substances in cord blood by turbulent flow chromatography coupled to tandem mass spectrometry

    International Nuclear Information System (INIS)

    Llorca, Marta; Pérez, Francisca; Farré, Marinella; Agramunt, Sílvia; Kogevinas, Manolis; Barceló, Damià

    2012-01-01

    A fast on-line analytical method based on turbulent flow chromatography (TFC) in combination with tandem mass spectrometry has been applied for the first time for the analysis of eighteen perfluoroalkyl substances (PFASs), in cord blood. A simple and rapid sample pre-treatment was optimised consisting on protein precipitation of 100 μL of sample with acetonitrile (1:1) followed by centrifugation during 10 min. The method was adapted to be sensitive enough and robust with minimum sample injection volume requirements (20 μL). The optimised methodology presented method limits of detection (MLOD) between 0.031 and 0.76 μg/L, detection capabilities (CCα) in the range between 0.005 and 0.99 μg/L and decision limits (CCβ) ranging from 0.006 to 1.16 μg/L. The recoveries in blank blood were calculated by spiking experiments with a mixture of 18 PFASs and established between 70 and 126% for most of compounds. Isotopic dilution was carried out for quantification of selected analytes. In-house validation of this new approach was carried out according to the requirements in the 2002/657/EC Decision. Finally the good applicability of this new approach was proved by the analysis of 60 cord blood samples from two different Mediterranean cities, Barcelona (Spain) and Heraklion (Greece). Ions perfluorohexanesulfonate (PFHxS) and perfluorooctanesulfonate (PFOS) were found at highest concentration and the more frequently compounds were PFHxS, PFOS and perfluorooctanoic acid (PFOA). The newly developed method proved to be suitable for large-scale epidemiologic studies, and to the data on PFASs exposure during pregnancy. -- Highlights: ► An on-line method has been developed for the analysis of 18 perfluoroalkyl substances. ► The method is based on turbulent flow chromatography tandem mass spectrometry. ► The method was applied in 60 cord blood samples from 2 Mediterranean cities. ► Acidic compounds were more frequently found and the method was proved to be suitable for

  3. Comprehensive lipidome analysis by shotgun lipidomics on a hybrid quadrupole-orbitrap-linear ion trap mass spectrometer

    DEFF Research Database (Denmark)

    Almeida, Reinaldo; Pauling, Josch Konstantin; Sokol, Elena

    2015-01-01

    , including its high resolution power unsurpassed by any other contemporary Orbitrap instrumentation, its dynamic quantification range and its efficacy for in-depth structural characterization of molecular lipid species by quadrupole-based higher-energy collisional dissociation (HCD), and ion trap...... and CID and ITMS(3) analysis utilizing dual CID for in-depth structural characterization of molecular glycerophospholipid species. The performance of the MS(ALL) method was benchmarked in a comparative analysis of mouse cerebellum and hippocampus. This analysis demonstrated extensive lipidome...

  4. Matrix effect on the determination of synthetic corticosteroids and diuretics by liquid chromatography-tandem mass spectrometry

    Science.gov (United States)

    Dikunets, M. A.; Appolonova, S. A.; Rodchenkov, G. M.

    2009-04-01

    This work presents a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) procedure for selective and reliable screening of corticosteroids and diuretics in human urine. Sample preparation included the extraction, evaporation of the organic extract under nitrogen, and solution of the dry residue. The extract was analyzed by HPLC combined with tandem mass spectrometry using electro-spraying ionization at atmospheric pressure with negative ion recording. The mass spectra of all compounds were recorded, and the characteristic ions, retention times, and detection limits were determined. The procedure was validated by evaluating the degree of the matrix suppression of ionization, extraction of analytes from human biological liquid, and the selectivity and specificity of determination.

  5. Similarity of High-Resolution Tandem Mass Spectrometry Spectra of Structurally Related Micropollutants and Transformation Products

    Science.gov (United States)

    Schollée, Jennifer E.; Schymanski, Emma L.; Stravs, Michael A.; Gulde, Rebekka; Thomaidis, Nikolaos S.; Hollender, Juliane

    2017-12-01

    High-resolution tandem mass spectrometry (HRMS2) with electrospray ionization is frequently applied to study polar organic molecules such as micropollutants. Fragmentation provides structural information to confirm structures of known compounds or propose structures of unknown compounds. Similarity of HRMS2 spectra between structurally related compounds has been suggested to facilitate identification of unknown compounds. To test this hypothesis, the similarity of reference standard HRMS2 spectra was calculated for 243 pairs of micropollutants and their structurally related transformation products (TPs); for comparison, spectral similarity was also calculated for 219 pairs of unrelated compounds. Spectra were measured on Orbitrap and QTOF mass spectrometers and similarity was calculated with the dot product. The influence of different factors on spectral similarity [e.g., normalized collision energy (NCE), merging fragments from all NCEs, and shifting fragments by the mass difference of the pair] was considered. Spectral similarity increased at higher NCEs and highest similarity scores for related pairs were obtained with merged spectra including measured fragments and shifted fragments. Removal of the monoisotopic peak was critical to reduce false positives. Using a spectral similarity score threshold of 0.52, 40% of related pairs and 0% of unrelated pairs were above this value. Structural similarity was estimated with the Tanimoto coefficient and pairs with higher structural similarity generally had higher spectral similarity. Pairs where one or both compounds contained heteroatoms such as sulfur often resulted in dissimilar spectra. This work demonstrates that HRMS2 spectral similarity may indicate structural similarity and that spectral similarity can be used in the future to screen complex samples for related compounds such as micropollutants and TPs, assisting in the prioritization of non-target compounds. [Figure not available: see fulltext.

  6. Rapid Screening of Multiclass Syrup Adulterants in Honey by Ultrahigh-Performance Liquid Chromatography/Quadrupole Time of Flight Mass Spectrometry.

    Science.gov (United States)

    Du, Bing; Wu, Liming; Xue, Xiaofeng; Chen, Lanzhen; Li, Yi; Zhao, Jing; Cao, Wei

    2015-07-29

    Honey adulteration with sugar syrups is a widespread problem. Several types of syrups have been used in honey adulteration, and there is no available method that can simultaneously detect all of these adulterants. In this study, we generated a small-scale database containing the specific chromatographic and mass spectrometry information on sugar syrup markers and developed a simple, rapid, and effective ultrahigh-performance liquid chromatography/quadrupole time-of-flight mass spectrometry (UHPLC/Q-TOF-MS) method for the detection of adulterated honey. Corn syrup, high-fructose corn syrup, inverted syrup, and rice syrup were used as honey adulterants; polysaccharides, difructose anhydrides, and 2-acetylfuran-3-glucopyranoside were used as detection markers. The presence of 10% sugar syrup in honey could be easily detected in <30 min using the developed method. The results revealed that UHPLC/Q-TOF-MS was simple and rapid.

  7. Highly informative multiclass profiling of lipids by ultra-high performance liquid chromatography - Low resolution (quadrupole) mass spectrometry by using electrospray ionization and atmospheric pressure chemical ionization interfaces.

    Science.gov (United States)

    Beccaria, Marco; Inferrera, Veronica; Rigano, Francesca; Gorynski, Krzysztof; Purcaro, Giorgia; Pawliszyn, Janusz; Dugo, Paola; Mondello, Luigi

    2017-08-04

    A simple, fast, and versatile method, using an ultra-high performance liquid chromatography system coupled with a low resolution (single quadrupole) mass spectrometer was optimized to perform multiclass lipid profiling of human plasma. Particular attention was made to develop a method suitable for both electrospray ionization and atmospheric pressure chemical ionization interfaces (sequentially in positive- and negative-ion mode), without any modification of the chromatographic conditions (mobile phase, flow-rate, gradient, etc.). Emphasis was given to the extrapolation of the structural information based on the fragmentation pattern obtained using atmospheric pressure chemical ionization interface, under each different ionization condition, highlighting the complementary information obtained using the electrospray ionization interface, of support for related molecule ions identification. Furthermore, mass spectra of phosphatidylserine and phosphatidylinositol obtained using the atmospheric pressure chemical ionization interface are reported and discussed for the first time. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. High performance liquid chromatography-tandem mass spectrometric assay of dexmedetomidine in plasma, urine and amniotic fluid samples for pregnant ewe model.

    Science.gov (United States)

    Cui, Z; Chow, D S-L; Wu, L; Lazar, D A; Rodrigo, R; Olutoye, O O; Olutoye, O A

    2014-06-15

    Dexmedetomidine (DEX; Precedex(®)), approved by the Food and Drug Administration (FDA) in 1999 as a sedative for use in the intensive care unit, is a potent and highly selective α2-adrenoceptor agonist with significant sedative, analgesic and anxiolytic effects. However, the research of DEX use during pregnancy is limited and the impact of DEX on the fetal development is unclear. This article describes a high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) assay suitable for various biomatrices of plasma, urine and amniotic fluid, as a prerequisite for pharmacokinetic characterization of DEX in the pregnant ewe model. DEX and testosterone (internal standard; IS) were extracted from 200μL of plasma, urine or amniotic fluid with ethyl acetate. The HPLC resolution was achieved on an Agilent ZORBAX SB-CN column with a gradient elution at a flow rate of 0.5mL/min using a mobile phase of 5-100% of acetonitrile with 0.5% formic acid (mobile phase B) in water (mobile phase A). The detection was performed by a triple quadrupole tandem mass spectrometer with positive electrospray ionization. The precursor/product transitions (m/z) in the positive ion mode [M+H](+) were m/z 201.5→95.4 for DEX and m/z 289.2→109.1 for IS. The method was validated in the concentration range of 25 (lower limit of quantification; LLOQ)-5000pg/mL for both maternal and fetal plasma, and of 50 (LLOQ)-5000pg/mL for urine and amniotic fluid, respectively. The intra- and inter-day precision and accuracy were within ±9%. The overall recoveries of DEX were 82.9-87.2%, 85.7-88.4%, 86.2-89.7% and 83.7-88.1% for maternal plasma, urine, fetal plasma and amniotic fluid, respectively. The percentage matrix factors in different biomatrices were less than 120%. Stability studies demonstrated that DEX was stable after three freeze/thaw cycles, in the autosampler tray at 20°C for 24h and during the 3h sample preparation at room temperature. The validated HPLC-MS/MS method has been

  9. Assesment of endocrinal and biochemical entities through liquid chromatography?tandem mass spectrometry/mass spectrometer: Inter-relative investigation of the interaction based cardiovascular formulation

    OpenAIRE

    Das, Rakesh; Pal, Tapan Kumar

    2015-01-01

    Background: Combinatory oral dosage treatment of atorvastatin (ATVS) and olmesartan (OLM) drugs to cardiovascular patients reflects unpredicted results instead of its individual therapy, which was accessed on quantification of endocrinal and biochemicals of plasma through liquid chromatography-tandem mass spectrometry/mass spectrometer (LCMS/MS). Objective: Mission was to track the remarkable biochemical variation in the plasma after induction of the combined formulation, to evaluate the phar...

  10. Determination of ractopamine in pig hair using liquid chromatography with tandem mass spectrometric detection.

    Science.gov (United States)

    Wu, Junlin; Liu, Xiaoyun; Peng, Yunping

    2014-01-01

    A quantitative analytical procedure for the determination of ractopamine in pig hair has been developed and validated. The hair samples were washed and incubated at 75°C with isoxuprine and hair extraction buffer. The drug present was quantified using mixed solid-phase extraction and liquid chromatography with tandem mass spectrometric detection. The limit of quantization (LOQ) was 10pg/mg and the intra-day precision at 25pg/mg and 750pg/mg was 0.49% and 2.8% respectively. Inter-day precision was 0.88% and 3.52% at the same concentrations. The hair extraction percentage recovery at 25pg/mg and 50ng/mL was 99.47% and 103.83% respectively. The extraction percentage recovery at 25pg/mg and 50ng/mg was 93.52% and 100.26% respectively. Our results showed that ractopamine residues persist in hair in 24days of withdrawal and also showed the possibility to test ractopamine from pig hair samples. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Determination of trinexapac in wheat by liquid chromatography-electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Hiemstra, Maurice; de Kok, André

    2003-09-24

    A quantitative and confirmatory method for the analysis of trinexapac (free acid metabolite of trinexapac-ethyl) in wheat is described. Residues were extracted from wheat with acetonitrile in aqueous phosphate buffer (pH 7) overnight. The extract was directly injected into the HPLC system. Chromatographic separation was achieved on an octadecylsilica column, and detection was performed by negative ion electrospray ionization tandem mass spectrometry. The precursor ion of trinexapac [M - H](-) at m/z 223 was subjected to collisional fragmentation with argon to yield two intense diagnostic product ions at m/z 135 and 179, respectively. Accuracy and specificity for routine analysis of trinexapac were demonstrated. The validated concentration range was 10-200 microg/kg based on a 0.10 g/mL wheat sample extract. Recoveries were within the range of 71-94%, with associated relative standard deviations better than 10%. The limit of detection for trinexapac in wheat was estimated at 5 microg/kg. The method has been applied to a survey of 100 samples of wheat. In 46% of the samples analyzed, a quantifiable amount of trinexapac was detected, ranging from 10 to 110 microg/kg. It has been demonstrated that analyses of trinexapac accurately reflect the total amount of residues of the plant growth regulator, trinexapac-ethyl, in the wheat samples following field application. No residues of the parent compound, trinexapac-ethyl, in wheat were detected.

  12. Liquid chromatography/electrospray ionisation tandem mass spectrometric study of sitagliptin and its stressed degradation products.

    Science.gov (United States)

    Vishnuvardhan, C; Radhakrishnanand, P; Navalgund, S G; Satheeshkumar, N

    2014-12-01

    A sensitive UPLC positive ion electrospray tandem mass spectrometry method was developed and validated for identification of degradation products of sitagliptin formed during stress study. Six of the major degradants were identi-fied with the proposed method. The separation of sitagliptin and its degradation products was achieved on a Acquity BEH C-18 column (50×2.1 mm, 1.7 µm) using a gradient programme. The mobile phase consists of solvent A (10 mM ammonium formate, pH 6.4 adjusted with formic acid) and solvent B (acetonitrile) and quantitative evaluation was performed at 267 nm with a flow rate of 0.15 mL min(-1). Suitability of this method for the quantitative determination of the drugs was proved by validation in accordance with International Conference on Harmonization (ICH) guidelines and can be used for routine analysis of sitagliptin formulations in quality control. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Identification of Protein Complexes from Tandem Affinity Purification/Mass Spectrometry Data via Biased Random Walk.

    Science.gov (United States)

    Cai, Bingjing; Wang, Haiying; Zheng, Huiru; Wang, Hui

    2015-01-01

    Systematic identification of protein complexes from protein-protein interaction networks (PPIs) is an important application of data mining in life science. Over the past decades, various new clustering techniques have been developed based on modelling PPIs as binary relations. Non-binary information of co-complex relations (prey/bait) in PPIs data derived from tandem affinity purification/mass spectrometry (TAP-MS) experiments has been unfairly disregarded. In this paper, we propose a Biased Random Walk based algorithm for detecting protein complexes from TAP-MS data, resulting in the random walk with restarting baits (RWRB). RWRB is developed based on Random walk with restart. The main contribution of RWRB is the incorporation of co-complex relations in TAP-MS PPI networks into the clustering process, by implementing a new restarting strategy during the process of random walk. Through experimentation on un-weighted and weighted TAP-MS data sets, we validated biological significance of our results by mapping them to manually curated complexes. Results showed that, by incorporating non-binary, co-membership information, significant improvement has been achieved in terms of both statistical measurements and biological relevance. Better accuracy demonstrates that the proposed method outperformed several state-of-the-art clustering algorithms for the detection of protein complexes in TAP-MS data.

  14. Optimized experimental workflow for tandem mass spectrometry molecular networking in metabolomics.

    Science.gov (United States)

    Olivon, Florent; Roussi, Fanny; Litaudon, Marc; Touboul, David

    2017-09-01

    New omics sciences generate massive amounts of data, requiring to be sorted, curated, and statistically analyzed by dedicated software. Data-dependent acquisition mode including inclusion and exclusion rules for tandem mass spectrometry is routinely used to perform such analyses. While acquisition parameters are well described for proteomics, no general rule is currently available to generate reliable metabolomic data for molecular networking analysis on the Global Natural Product Social Molecular Networking platform (GNPS). Following on from an exploration of key parameters influencing the quality of molecular networks, universal optimal acquisition conditions for metabolomic studies are suggested in the present paper. The benefit of data pre-clustering before initiating large datasets for GNPS analyses is also demonstrated. Moreover, an efficient workflow dedicated to Agilent Technologies instruments is described, making the dereplication process easier by unambiguously distinguishing isobaric isomers eluted at different retention times, annotating the molecular networks with chemical formulas, and giving access to semi-quantitative data. This specific workflow foreshadows future developments of the GNPS platform.

  15. Glycerophospholipid analysis of Eastern red bat (Lasiurus borealis) hair by electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Pannkuk, Evan L; McGuire, Liam P; Gilmore, David F; Savary, Brett J; Risch, Thomas S

    2014-03-01

    Pilosebaceous units found in the mammalian integument are composed of a hair follicle, the proximal portion of the hair shaft, a sebaceous gland, and the erector pili muscle. Pilosebaceous units release protective oils, or sebum, by holocrine secretion onto skin and hair through rupturing of sebocytes. Sebum is composed largely of polar and neutral lipids including glycerolipids, free fatty acids, sterols, wax esters, sterol esters, and squalene. In addition to these lipid classes, there is a small proportion of ionic/anionic glycerophospholipids (GPs). Composition of GPs on hair is rarely addressed despite their broad biological activities as signaling molecules and membrane stability. Furthermore, knowledge on GP composition in bats is lacking. Bat GP composition is important to document due to GP roles ranging from decreasing drag during migration to interaction with the integumentary microbiome. In this study, we analyzed GP molecular composition with liquid chromatography electrospray ionization tandem mass spectrometry and compared GP content to previous literature. A total of 152 GPs were detected. Broad GP classes identified include lysophosphatidylcholine, phosphatidylcholine (PC), lysophosphatidylethanolamine, phosphatidylethanolamine, phosphatidylinositol, phosphatidylserine, phosphatidic acid, and phosphatidylglycerol, with PC being the most abundant class. The acyl components were consistent with fatty acid methyl esters and triacylglyceride moieties found in Eastern red bat sebum. Glycerophospholipid proportions of the hair surface were different from a previous study on bat lung surfactants. This study determined the broad class and molecular species of bat sebum GPs that may be used in future ecological studies in vespertilionid bats.

  16. Targeted liquid chromatography tandem mass spectrometry to quantitate wheat gluten using well-defined reference proteins.

    Directory of Open Access Journals (Sweden)

    Kathrin Schalk

    Full Text Available Celiac disease (CD is an inflammatory disorder of the upper small intestine caused by the ingestion of storage proteins (prolamins and glutelins from wheat, barley, rye, and, in rare cases, oats. CD patients need to follow a gluten-free diet by consuming gluten-free products with gluten contents of less than 20 mg/kg. Currently, the recommended method for the quantitative determination of gluten is an enzyme-linked immunosorbent assay (ELISA based on the R5 monoclonal antibody. Because the R5 ELISA mostly detects the prolamin fraction of gluten, a new independent method is required to detect prolamins as well as glutelins. This paper presents the development of a method to quantitate 16 wheat marker peptides derived from all wheat gluten protein types by liquid chromatography tandem mass spectrometry (LC-MS/MS in the multiple reaction monitoring mode. The quantitation of each marker peptide in the chymotryptic digest of a defined amount of the respective reference wheat protein type resulted in peptide-specific yields. This enabled the conversion of peptide into protein type concentrations. Gluten contents were expressed as sum of all determined protein type concentrations. This new method was applied to quantitate gluten in wheat starches and compared to R5 ELISA and gel-permeation high-performance liquid chromatography with fluorescence detection (GP-HPLC-FLD, which resulted in a strong correlation between LC-MS/MS and the other two methods.

  17. Analysis of nerve agent metabolites from nail clippings by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Appel, Amanda S; Logue, Brian A

    2016-09-15

    While several methods for the bioanalysis of nerve agents or their metabolites have been developed for the verification of nerve agent exposure, these methods are generally limited in the amount of time after an exposure that markers of exposure can be detected (due to rapid metabolism from biological matrices). In this study, a method for the analysis of nerve agent hydrolysis products from nail clippings was developed to allow evaluation of nails as a long-term repository of these markers. Pinacolyl methylphosphonic acid (PMPA) and isopropyl methylphosphonic acid (IMPA) were extracted from nail samples with N,N-dimethylformamide and subsequently analyzed by liquid chromatography-tandem mass spectrometry. Limits of detection for PMPA and IMPA were 0.3μg/kg and 7.5μg/kg and linear ranges were 0.75-300μg/kg and 30-1500μg/kg, respectively. Precision was within 10% and 8% for PMPA and IMPA, respectively, and accuracy was 100±12% for both analytes. The approach presented here is complementary to current methods for nerve agent exposure verification, and should allow for long-term determination of nerve agent poisoning. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Glycoalkaloid content in pet food by UPLC-tandem mass spectrometry.

    Science.gov (United States)

    Sheridan, Robert S; Kemnah, Jennifer L

    2010-11-01

    The glycoalkaloid content of pet food containing potatoes is investigated using a liquid-liquid solvent extraction followed by analysis by ultra-high pressure liquid chromatography tandem mass spectrometry (UPLC-MS-MS). Pet food samples are homogenized and extracted with a solution of 50:50 (v/v) acetonitrile-deionized water containing 5% acetic acid. Following vortexing and centrifugation, 3 mL of the supernatant is filtered and diluted in deionized water. The extract is injected onto a reverse phase C18 UPLC column with an initial mobile phase composed of 0.15% acetic acid in water (A) and 0.15% acetic acid in methanol (B) in a ratio of 70:30, respectively. The mobile phase reaches a final concentration of 15% A and 85% B over 10 min, at which point it is returned to the initial conditions. α-Solanine is measured by monitoring transitions m/z = 868.50 → 398.40 and 868.50 → 722.50, while α-chaconine is measure by monitoring transitions m/z = 852.60 → 97.80 and 852.60 → 706.50. Each analyte is measured and combined to determine total glycoalkaloid content (TGA). The results of the analysis of 52 pet food samples indicate both glycoalkaloids are present in all samples and two pet foods were found to contain > 100 μg/g total glycoalkaloid.

  19. Development of a dedicated peptide tandem mass spectral library for conservation science.

    Science.gov (United States)

    Fremout, Wim; Dhaenens, Maarten; Saverwyns, Steven; Sanyova, Jana; Vandenabeele, Peter; Deforce, Dieter; Moens, Luc

    2012-05-30

    In recent years, the use of liquid chromatography tandem mass spectrometry (LC-MS/MS) on tryptic digests of cultural heritage objects has attracted much attention. It allows for unambiguous identification of peptides and proteins, and even in complex mixtures species-specific identification becomes feasible with minimal sample consumption. Determination of the peptides is commonly based on theoretical cleavage of known protein sequences and on comparison of the expected peptide fragments with those found in the MS/MS spectra. In this approach, complex computer programs, such as Mascot, perform well identifying known proteins, but fail when protein sequences are unknown or incomplete. Often, when trying to distinguish evolutionarily well preserved collagens of different species, Mascot lacks the required specificity. Complementary and often more accurate information on the proteins can be obtained using a reference library of MS/MS spectra of species-specific peptides. Therefore, a library dedicated to various sources of proteins in works of art was set up, with an initial focus on collagen rich materials. This paper discusses the construction and the advantages of this spectral library for conservation science, and its application on a number of samples from historical works of art. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. GLYCEROPHOSPHOLIPID ANALYSIS OF EASTERN RED BAT (Lasiurus borealis) HAIR BY ELECTROSPRAY IONIZATION TANDEM MASS SPECTROMET

    Science.gov (United States)

    Pannkuk, Evan L.; McGuire, Liam P.; Gilmore, David F.; Savary, Brett J.; Risch, Thomas S.

    2014-01-01

    Pilosebaceous units found in the mammalian integument are composed of a hair follicle, the proximal portion of the hair shaft, a sebaceous gland, and the erector pili muscle. Pilosebaceous units release protective oils, or sebum, by holocrine secretion onto skin and hair through rupturing of sebocytes. Sebum is largely composed of polar and neutral lipids including glycerolipids, free fatty acids, sterols, wax esters, sterol esters, and squalene. In addition to these lipid classes, there is a small proportion of ionic/anionic glycerophospholipids (GPs). Composition of GPs on hair is rarely addressed despite their broad biological activities as signaling molecules and membrane stability. Furthermore, knowledge on GP composition in bats is lacking. Bat GP composition is important to document due to GP roles ranging from decreasing drag during migration to interaction with the integumentary microbiome. In this study, we analyzed GP molecular composition with liquid chromatography electrospray ionization tandem mass spectrometry and compared GP content to previous literature. A total of 152 GPs were detected. Broad GP classes identified include lysophosphatidylcholine, phosphatidylcholine (PC), lysophosphatidylethanolamine, phosphatidylethanolamine, phosphatidylinositol, phosphatidylserine, phosphatidic acid, and phosphatidylglycerol, with PC being the most abundant class. The acyl components were consistent with fatty acid methyl esters and triacylglyceride moieties found in Eastern red bat sebum. GP proportions of the hair surface were different from a previous study on bat lung surfactants. This study determined the broad class and molecular species of bat sebum GPs that may be used in future ecological studies in vespertilionid bats. PMID:24532214

  1. [Determination of amitrole in agricultural products by high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Li, Li; Fu, Jian; Gao, Hongliang; Ren, Haitao; Lou, Xishan; Guan, Lihui

    2010-03-01

    A high performance liquid chromatography-tandem mass spectrometry method (HPLC-MS/MS) was developed for the analysis of amitrole residues in agricultural products. The samples were extracted by 25% acetone for wheat, fish, pork and liver samples, 1% acetic acid-25% acetone for maize and peanut samples, 1% acetic acid solution for honeysuckle, the powder of ginger, the powder of bunge prickly ash and tea leaves samples, 1% acetic acid solution-dichloromethane for apple, pineapple, spinach, carrot, perilla leaves samples, respectively, followed by liquid-liquid extraction with dichloromethane. The samples were then cleaned up by PCX or Envi-Carb solid-phase extraction cartridge. The amitrole was determined and confirmed by HPLC-MS/MS. The results showed a linear relationship in the range of 0.005 -0.1 mg/kg for amitrole. The correlation coefficient was 0.999 7. The average recoveries of amitrole in wheat, maize, peanut, pineapple, apple, carrot, spinach, pork, the powder of ginger, the powder of bunge prickly ash, perilla, liver, fish, honeysuckle and tea were 67.5% - 98.1%. The relative standard deviations (RSDs) were 1.0% - 9.8%. The limits of quantitation were 10 microg/kg for wheat, maize, peanut, pineapple, apple, carrot, spinach, pork, perilla, liver, fish, honeysuckle and 20 microg/kg for the powder of bunge prickly ash, the powder of ginger and tea, respectively. The method is simple, sensitive and accurate.

  2. Correction of errors in tandem mass spectrum extraction enhances phosphopeptide identification.

    Science.gov (United States)

    Hao, Piliang; Ren, Yan; Tam, James P; Sze, Siu Kwan

    2013-12-06

    The tandem mass spectrum extraction of phosphopeptides is more difficult and error-prone than that of unmodified peptides due to their lower abundance, lower ionization efficiency, the cofragmentation with other high-abundance peptides, and the use of MS(3) on MS(2) fragments with neutral losses. However, there are still no established methods to evaluate its correctness. Here we propose to identify and correct these errors via the combinatorial use of multiple spectrum extraction tools. We evaluated five free and two commercial extraction tools using Mascot and phosphoproteomics raw data from LTQ FT Ultra, in which RawXtract 1.9.9.2 identified the highest number of unique phosphopeptides (peptide expectation value exporting MS/MS fragments. We then corrected the errors by selecting the best extracted MGF file for each spectrum among the three tools for another database search. With the errors corrected, it results in the 22.4 and 12.2% increase in spectrum matches and unique peptide identification, respectively, compared with the best single method. Correction of errors in spectrum extraction improves both the sensitivity and confidence of phosphopeptide identification. Data analysis on nonphosphopeptide spectra indicates that this strategy applies to unmodified peptides as well. The identification of errors in spectrum extraction will promote the improvement of spectrum extraction tools in future.

  3. Liquid chromatography coupled to tandem mass spectrometry for detecting ten allergens in complex and incurred foodstuffs.

    Science.gov (United States)

    Planque, M; Arnould, T; Dieu, M; Delahaut, P; Renard, P; Gillard, N

    2017-12-29

    Food allergy is a considerable heath problem, as undesirable contaminations by allergens during food production are still widespread and may be dangerous for human health. To protect the population, laboratories need to develop reliable analytical methods in order to detect allergens in various food products. Currently, a large majority of allergen-related food recalls concern bakery products. It is therefore essential to detect allergens in unprocessed and processed foodstuffs. In this study, we developed a method for detecting ten allergens in complex (chocolate, ice cream) and processed (cookie, sauce) foodstuffs, based on ultra-high performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS). Using a single protocol and considering a signal-to-noise ratio higher than 10 for the most abundant multiple reaction monitoring (MRM) transition, we were able to detect target allergens at 0.5mg/kg for milk proteins, 2.5mg/kg for peanut, hazelnut, pistachio, and cashew proteins, 3mg/kg for egg proteins, and 5mg/kg for soy, almond, walnut, and pecan proteins. The ability of the method to detect 10 allergens with a single protocol in complex and incurred food products makes it an attractive alternative to the ELISA method for routine laboratories. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. [Determination of 25 quinolones in cosmetics by liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Lin, Li; Zhang, Yi; Tu, Xiaoke; Xie, Liqi; Yue, Zhenfeng; Kang, Haining; Wu, Weidong; Luo, Yao

    2015-03-01

    An analytical method was developed for the simultaneous determination of 25 quinolones, including danofloxacin mesylate, enrofloxacin, flumequine, oxloinic acid, ciprofloxacin, sarafloxacin, nalidixic acid, norfloxacin, and ofloxacin etc in cosmetics using direct extraction and liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). Cosmetic sample was extracted by acidified acetonitrile, defatted by n-hexane and separated on Poroshell EC-C18 column with gradient elution program using acetonitrile and water (both containing 0. 1% formic acid) as the mobile phases and analyzed by LC-ESI-MS/MS under the positive mode using multiple reaction monitoring (MRM). The interference of matrix was reduced by the matrix-matched calibration standard curve. The method showed good linearities over the range of 1-200 mg/kg for the 25 quinolones with good linear correlation coefficients (r ≥ 0.999). The method detection limit of the 25 quinolones was 1.0 mg/kg, and the recoveries of all analytes in lotion, milky and cream cosmetics matrices ranged from 87.4% to 105% at the spiked levels of 1, 5 and 10 mg/kg with the relative standard deviations (RSD) of 4.54%-19.7% (n = 6). The results indicated that this method is simple, fast and credible, and suitable for the simultaneous determination of the quinolones in the above three types of cosmetics.

  5. Capillary-HPLC with tandem mass spectrometry in analysis of alkaloid dyestuffs - a new approach.

    Science.gov (United States)

    Dąbrowski, Damian; Lech, Katarzyna; Jarosz, Maciej

    2017-11-10

    Development of the identification method of alkaloid compounds in Amur cork tree as well as not examined so far Oregon grape and European Barberry shrubs are presented. The novel approach to separation of alkaloids was applied and the capillary-high-performance liquid chromatography (capillary-HPLC) system was used, which has never previously been reported for alkaloid-based dyestuffs analysis. Its optimization was conducted with three different stationary phases (unmodified octadecylsilane-bonded silica, octadecylsilane modified with polar groups and silica-bonded pentaflourophenyls) as well as with different solvent buffers. Detection of the isolated compounds was carried out using diode-array detector (DAD) and tandem mass spectrometer with electrospray ionization (ESI MS/MS). The working parameters of ESI were optimized, whereas the multiple reactions monitoring (MRM) parameters of MS/MS detection were chosen based on the product ion spectra of the quasi-molecular ions. Calibration curve of berberine has been estimated (y = 1712091x + 4785.03 with the correlation coefficient 0.9999). Limit of detection and limit of quantification were calculated to be 3.2 and 9.7 ng/mL, respectively. Numerous alkaloids (i.e., berberine, jatrorrhizine and magnoflorine, as well as phellodendrine, menisperine and berbamine) were identified in the extracts from alkaloid plants and silk and wool fibers dyed with these dyestuffs, among them their markers. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Sensitive quantification of diphemanil methyl sulphate in human plasma by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Do, B; Goulay-Dufaÿ, S; Le Hoang, M D; Adoui, N; Graffard, H; Guyon, F; Pradeau, D

    2007-01-01

    A simple detection system with a high-performance liquid chromatography (HPLC) with positive ionisation-tandem mass spectrometry (ESI-MS/MS) for determining diphemanil methylsulphate (DMS) levels in human plasma using 4-diphemanylmethylene,1-methylpiperidine as an internal standard (I.S.), is proposed. The acquisition was performed with the multiple reactional monitoring (MRM) mode, by monitoring the transitions: m/z 278>262 for DMS and m/z 263>247 for the I.S. The method involved a simple single-step deproteinisation with acetonitrile. The analyte was chromatographed on a Zorbax C18 reversed-phase chromatographic column by isocratic elution with 10(-3)M ammonium acetate and 10(-3)M hexafluorobutyric acid, adjusted to pH 7.0 with ammoniac/acetonitrile (40/60, v/v). The results were linear over the studied range (0.5-50.0 ng mL(-1)) and the total analysis time for each run was 10 min. The mean extraction apparent recoveries expressed at the 95% intervals of confidence were 94-104% for DMS and 92-106% for the I.S. The intra- and inter-assay precisions were 4.6-8.4% and 2.9-10.6%, respectively. The limit of quantification was 0.15 ng mL(-1). The devised assay was successfully applied to the residual concentrations monitoring in infant.

  7. Real-time hydrogen/deuterium exchange kinetics via supercharged electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Sterling, Harry J; Williams, Evan R

    2010-11-01

    Amide hydrogen/deuterium exchange (HDX) rate constants of bovine ubiquitin in an ammonium acetate solution containing 1% of the electrospray ionization (ESI) "supercharging" reagent m-nitrobenzyl alcohol (m-NBA) were obtained using top-down, electron transfer dissociation (ETD) tandem mass spectrometry (MS). The supercharging reagent replaces the acid and temperature "quench" step in the conventional MS approach to HDX experiments by causing rapid protein denaturation to occur in the ESI droplet. The higher charge state ions that are produced with m-NBA are more unfolded, as measured by ion mobility, and result in higher fragmentation efficiency and higher sequence coverage with ETD. Single amino acid resolution was obtained for 44 of 72 exchangeable amide sites, and summed kinetic data were obtained for regions of the protein where adjacent fragment ions were not observed, resulting in an overall spatial resolution of 1.3 residues. Comparison of these results with previous values from NMR indicates that the supercharging reagent does not cause significant structural changes to the protein in the initial ESI solution and that scrambling or back-exchange is minimal. This new method for top-down HDX-MS enables real-time kinetic data measurements under physiological conditions, similar to those obtained using NMR, with comparable spatial resolution and significantly better sensitivity.

  8. Technological Journey From Colorimetric to Tandem Mass Spectrometric Measurements in the Diagnostic Investigation for Phenylketonuria

    Directory of Open Access Journals (Sweden)

    Donald H. Chace PhD

    2016-10-01

    Full Text Available Phenylalanine analysis for phenylketonuria (PKU detection in newborn screening (NBS was chosen as the model system to describe how advancements in laboratory technology improved laboratory performance. These advancements have made NBS programs better and have improved the health outcomes of the affected newborn through improvements in accurate early detection over the past 50 years. The most current state-of-the-art technology, tandem mass spectrometry (MS/MS, has proven that it is now the choice in almost all modern NBS facilities because it is a versatile instrument that continues to grow in its application not just for amino acid and acylcarnitine detection but for other metabolites and disorders such as lysosomal storage diseases and second-tier detection of some screen-positive results. The use of MS/MS will continue to expand, even with the anticipated introduction and expansion of molecular screening methods into NBS programs. Regarding technological advancements, the future of NBS will include even newer technologies and approaches that will enhance the detection and treatment of newborns affected by PKU and other inborn errors of metabolism.

  9. Next generation offline approaches to trace organic compound speciation: Approaching comprehensive speciation with soft ionization and very high resolution tandem mass spectrometry

    Science.gov (United States)

    Khare, P.; Marcotte, A.; Sheu, R.; Ditto, J.; Gentner, D. R.

    2017-12-01

    Intermediate- and semi-volatile organic compounds (IVOCs and SVOCs) have high secondary organic aerosol (SOA) yields, as well as significant ozone formation potentials. Yet, their emission sources and oxidation pathways remain largely understudied due to limitations in current analytical capabilities. Online mass spectrometers are able to collect real time data but their limited mass resolving power renders molecular level characterization of IVOCs and SVOCs from the unresolved complex mixture unfeasible. With proper sampling techniques and powerful analytical instrumentation, our offline tandem mass spectrometry (i.e. MS×MS) techniques provide molecular-level and structural identification over wide polarity and volatility ranges. We have designed a novel analytical system for offline analysis of gas-phase SOA precursors collected on custom-made multi-bed adsorbent tubes. Samples are desorbed into helium via a gradual temperature ramp and sample flow is split equally for direct-MS×MS analysis and separation via gas chromatography (GC). The effluent from GC separation is split again for analysis via atmospheric pressure chemical ionization quadrupole time-of-flight mass spectrometry (APCI-Q×TOF) and traditional electron ionization mass spectrometry (EI-MS). The compounds for direct-MS×MS analysis are delivered via a transfer line maintained at 70ºC directly to APCI-Q×TOF, thus preserving the molecular integrity of thermally-labile, or other highly-reactive, organic compounds. Both our GC-MS×MS and direct-MS×MS analyses report high accuracy parent ion masses as well as information on molecular structure via MS×MS, which together increase the resolution of unidentified complex mixtures. We demonstrate instrument performance and present preliminary results from urban atmospheric samples collected from New York City with a wide range of compounds including highly-functionalized organic compounds previously understudied in outdoor air. Our work offers new

  10. Trace analysis of total naphthenic acids in aqueous environmental matrices by liquid chromatography/mass spectrometry-quadrupole time of flight mass spectrometry direct injection.

    Science.gov (United States)

    Brunswick, Pamela; Shang, Dayue; van Aggelen, Graham; Hindle, Ralph; Hewitt, L Mark; Frank, Richard A; Haberl, Maxine; Kim, Marcus

    2015-07-31

    A rapid and sensitive liquid chromatography quadrupole time of flight method has been established for the determination of total naphthenic acid concentrations in aqueous samples. This is the first methodology that has been adopted for routine, high resolution, high throughput analysis of total naphthenic acids at trace levels in unprocessed samples. A calibration range from 0.02 to 1.0μgmL(-1) total Merichem naphthenic acids was validated and demonstrated excellent accuracy (97-111% recovery) and precision (1.9% RSD at 0.02μgmL(-1)). Quantitative validation was also demonstrated in a non-commercial oil sands process water (OSPW) acid extractable organics (AEOs) fraction containing a higher percentage of polycarboxylic acid isomers than the Merichem technical mix. The chromatographic method showed good calibration linearity of ≥0.999 RSQ to 0.005μgmL(-1) total naphthenic acids with a precision <3.1% RSD and a calculated detection limit of 0.0004μgmL(-1) employing Merichem technical mix reference material. The method is well suited to monitoring naturally occurring and industrially derived naphthenic acids (and other AEOs) present in surface and ground waters in the vicinity of mining developments. The advantage of the current method is its direct application to unprocessed environmental samples and to examine natural naphthenic acid isomer profiles. It is noted that where the isomer profile of samples differs from that of the reference material, results should be considered semi-quantitative due to the lack of matching isomer content. The fingerprint profile of naphthenic acids is known to be transitory during aging and the present method has the ability to adapt to monitoring of these changes in naphthenic acid content. The method's total ion scan approach allows for data previously collected to be examined retrospectively for specific analyte mass ions of interest. A list of potential naphthenic acid isomers that decrease in response with aging is proposed

  11. Identification and Quantification of Glucosinolates in Kimchi by Liquid Chromatography-Electrospray Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Ho Jin Kim

    2017-01-01

    Full Text Available A novel and simple method for detecting five glucosinolates (glucoalyssin, gluconapin, glucobrassicanapin, glucobrassicin, and 4-methoxyglucobrassicin in kimchi was developed using liquid chromatography-electrospray tandem mass spectrometry (LC-MS/MS. The chromatographic peaks of the five glucosinolates were successfully identified by comparing their retention times, mass spectra. The mobile phase was composed of A (acetonitrile and B (water. As for glucosinolate, the relative quantities were found through sinigrin, and five different compounds that have not been previously discovered in kimchi were observed. Monitoring was carried out on the glucosinolate in 20 kimchis distributed in markets, and this study examined the various quality and quantity compositions of the five components. The glucoalyssin content ranged from 0.00 to 7.07 μmol/g of day weight (DW, with an average content of 0.86 μmol/g of DW, whereas the gluconapin content ranged from 0.00 to 5.85 μmol/g of DW, with an average of 1.17 μmol/g of DW. The content of glucobrassicanapin varied between 0.00 and 11.87 μmol/g of DW (average = 3.03 μmol/g of DW, whereas that of glucobrassicin varied between 0.00 and 0.42 μmol/g of DW (average = 0.06 μmol/g of DW. The 4-methoxyglucobrassicin content ranged from 0.12 to 9.36 μmol/g of DW (average = 3.52 μmol/g of DW. A comparison of the contents revealed that, in most cases, the content of 4-methoxyglucobrassicin was the highest.

  12. Computational refinement of post-translational modifications predicted from tandem mass spectrometry.

    Science.gov (United States)

    Chung, Clement; Liu, Jian; Emili, Andrew; Frey, Brendan J

    2011-03-15

    A post-translational modification (PTM) is a chemical modification of a protein that occurs naturally. Many of these modifications, such as phosphorylation, are known to play pivotal roles in the regulation of protein function. Henceforth, PTM perturbations have been linked to diverse diseases like Parkinson's, Alzheimer's, diabetes and cancer. To discover PTMs on a genome-wide scale, there is a recent surge of interest in analyzing tandem mass spectrometry data, and several unrestrictive (so-called 'blind') PTM search methods have been reported. However, these approaches are subject to noise in mass measurements and in the predicted modification site (amino acid position) within peptides, which can result in false PTM assignments. To address these issues, we devised a machine learning algorithm, PTMClust, that can be applied to the output of blind PTM search methods to improve prediction quality, by suppressing noise in the data and clustering peptides with the same underlying modification to form PTM groups. We show that our technique outperforms two standard clustering algorithms on a simulated dataset. Additionally, we show that our algorithm significantly improves sensitivity and specificity when applied to the output of three different blind PTM search engines, SIMS, InsPecT and MODmap. Additionally, PTMClust markedly outperforms another PTM refinement algorithm, PTMFinder. We demonstrate that our technique is able to reduce false PTM assignments, improve overall detection coverage and facilitate novel PTM discovery, including terminus modifications. We applied our technique to a large-scale yeast MS/MS proteome profiling dataset and found numerous known and novel PTMs. Accurately identifying modifications in protein sequences is a critical first step for PTM profiling, and thus our approach may benefit routine proteomic analysis. Our algorithm is implemented in Matlab and is freely available for academic use. The software is available online from http://genes.toronto.edu.

  13. Characterisation of polyacetylenes isolated from carrot (Daucus carota) extracts by negative ion tandem mass spectrometry.

    Science.gov (United States)

    Rai, Dilip K; Brunton, Nigel P; Koidis, Anastasios; Rawson, Ashish; McLoughlin, Padraig; Griffiths, William J

    2011-08-15

    The potential use of negative electrospray ionisation mass spectrometry (ESI-MS) in the characterisation of the three polyacetylenes common in carrots (Daucus carota) has been assessed. The MS scans have demonstrated that the polyacetylenes undergo a modest degree of in-source decomposition in the negative ionisation mode while the positive ionisation mode has shown predominantly sodiated ions and no [M+H](+) ions. Tandem mass spectrometric (MS/MS) studies have shown that the polyacetylenes follow two distinct fragmentation pathways: one that involves cleavage of the C3-C4 bond and the other with cleavage of the C7-C8 bond. The cleavage of the C7-C8 bond generated product ions m/z 105.0 for falcarinol, m/z 105/107.0 for falcarindiol, m/z 147.0/149.1 for falcarindiol-3-acetate. In addition to these product ions, the transitions m/z 243.2 → 187.1 (falcarinol), m/z 259.2 → 203.1 (falcarindiol), m/z 301.2 → 255.2/203.1 (falcarindiol-3-acetate), mostly from the C3-C4 bond cleavage, can form the basis of multiple reaction monitoring (MRM)-quantitative methods which are poorly represented in the literature. The 'MS(3) ' experimental data confirmed a less pronounced homolytic cleavage site between the C11-C12 bond in the falcarinol-type polacetylenes. The optimised liquid chromatography (LC)/MS conditions have achieved a baseline chromatographic separation of the three polyacetylenes investigated within 40 min total run-time. Copyright © 2011 John Wiley & Sons, Ltd.

  14. A rapid quantitative analysis of bile acids, lysophosphatidylcholines and polyunsaturated fatty acids in biofluids based on ultraperformance liquid chromatography coupled with triple quadrupole tandem massspectrometry.

    Science.gov (United States)

    Peng, Zhangxiao; Zhang, Qian; Mao, Ziming; Wang, Jie; Liu, Chunying; Lin, Xuejing; Li, Xin; Ji, Weidan; Fan, Jianhui; Wang, Maorong; Su, Changqing

    2017-11-15

    Much evidence suggested that quantitative analysis of bile acids (BAs), lysophosphatidylcholines (LPCs), and polyunsaturated fatty acids (PUFAs) in biofluids may be very useful for diagnosis and prevention of hepatobiliary disease with a non-invasive manner. However, simultaneously fast analysis of these metabolites has been challenging for their huge differences of physicochemical properties and concentration levels in biofluids. In this study, we present a liquid chromatography-mass spectrometry method with a high throughput analytical cycle (10min) to fast and accurately quantify fifteen potential biomarkers (eight BAs, four LPCs and three PUFAs) of hepatobiliary disease. The accuracy for the fifteen analytes in plasma and urine matrices was 80.45%-118.99% and 84.55%-112.66%, respectively. The intra- and inter- precisions for the fifteen analytes in plasma and urine matrices were all less than 20% and the lower limit of quantification (LLOQ) of analytes is up to 0.0283-8.2172nmol/L. Therefore, this method is fast, sensitive and accurate for the quantitative analysis of BAs, LPCs and PUFAs in biofluids. Moreover, the stability and concentration differences of the analytes in plasma and serum were evaluated, and the results demonstrated that LPCs is stable, but PUFAs is very unstable in freeze and thaw cycles, and the concentrations of the analytes in serum were slightly higher than those in plasma. We suggested plasma may be a kind of better bio-sample than serum using for quantitative analysis of metabolites in blood, due to the characteristics of plasma are more close to blood than those of serum. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Direct determination of trace phthalate esters in alcoholic spirits by spray-inlet microwave plasma torch ionization tandem mass spectrometry.

    Science.gov (United States)

    Miao, Meng; Zhao, Gaosheng; Xu, Li; Dong, Junguo; Cheng, Ping

    2018-03-01

    A direct analytical method based on spray-inlet microwave plasma torch tandem mass spectrometry was applied to simultaneously determine 4 phthalate esters (PAEs), namely, benzyl butyl phthalate, diethyl phthalate, dipentyl phthalate, and dodecyl phthalate with extremely high sensitivity in spirits without sample treatment. Among the 4 brands of spirit products, 3 kinds of PAE compounds were directly determined at very low concentrations from 1.30 to 114 ng·g -1 . Compared with other online and off-line methods, the spray-inlet microwave plasma torch tandem mass spectrometry technique is extremely simple, rapid, sensitive, and high efficient, providing an ideal screening tool for PAEs in spirits. Copyright © 2017 John Wiley & Sons, Ltd.

  16. Direct Analysis in Real Time (DART) of an Organothiophosphate at Ultrahigh Resolution by Fourier Transform Ion Cyclotron Resonance Mass Spectrometry and Tandem Mass Spectrometry.

    Science.gov (United States)

    Prokai, Laszlo; Stevens, Stanley M

    2016-01-16

    Direct analysis in real time (DART) is a recently developed ambient ionization technique for mass spectrometry to enable rapid and sensitive analyses with little or no sample preparation. After swab-based field sampling, the organothiophosphate malathion was analyzed using DART-Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry (MS) and tandem mass spectrometry (MS/MS). Mass resolution was documented to be over 800,000 in full-scan MS mode and over 1,000,000 for an MS/MS product ion produced by collision-induced dissociation of the protonated analyte. Mass measurement accuracy below 1 ppm was obtained for all DART-generated ions that belonged to the test compound in the mass spectra acquired using only external mass calibration. This high mass measurement accuracy, achievable at present only through FTMS, was required for unequivocal identification of the corresponding molecular formulae.

  17. A high-resolution tandem mass spectrometer for the collision-induced dissociation of large molecule ions

    International Nuclear Information System (INIS)

    Ouwerkerk, C.E.D.

    1988-01-01

    Instrumental development in the field of tandem mass spectrometry is described in order to use the technique for the analysis of large organic molecules. Experiments are also described in which the process of collision-induced dissociation (CID) is investigated. The fragmentation pattern of CH 4 + has been measured for three different target gases He, Ar and Xe. From these measurements fragmentation cross sections are calculated. 192 refs.; 47 figs.; 6 tabs

  18. Characterization of bisphenol A metabolites produced by Portulaca oleracea cv. by liquid chromatography coupled with tandem mass spectrometry.

    Science.gov (United States)

    Watanabe, Ippei; Harada, Kazuo; Matsui, Takeshi; Miyasaka, Hitoshi; Okuhata, Hiroshi; Tanaka, Satoshi; Nakayama, Hideki; Kato, Ko; Bamba, Takeshi; Hirata, Kazumasa

    2012-01-01

    The garden plant portulaca (Portulaca oleracea cv.) efficiently removes bisphenol A (BPA), an endocrine-disrupting chemical, from a hydroponic solution, but the molecular mechanisms underlying BPA metabolism by portulaca remain unclear. In this study, BPA metabolites converted by portulaca were analyzed by liquid chromatography coupled with tandem mass spectrometry. We observed the hydroxylation of BPA and the oxidization of it to quinone. Polyphenol oxidases are likely to contribute to BPA degradation by portulaca.

  19. Determination of ∆-9-Tetrahydrocannabinol (THC), 11-hydroxy-THC, 11-nor-9-carboxy-THC and Cannabidiol in Human Plasma using Gas Chromatography-Tandem Mass Spectrometry.

    Science.gov (United States)

    Andrenyak, David M; Moody, David E; Slawson, Matthew H; O'Leary, Daniel S; Haney, Margaret

    2017-05-01

    Two marijuana compounds of particular medical interest are delta-9-tetrahydrocannabinol (THC) and cannabidiol (CBD). A gas chromatography-tandem mass spectrometry (GC-MS-MS) method was developed to test for CBD, THC, hydroxy-THC (OH-THC) and carboxy-THC (COOH-THC) in human plasma. Calibrators (THC and OH-THC, 0.1 to 100; CBD, 0.25 to 100; COOH-THC, 0.5-500 ng/mL) and controls (0.3, 5 and 80 ng/mL, except COOH-THC at 1.5, 25 and 400 ng/mL) were prepared in blank matrix. Deuterated (d3) internal standards were added to 1-mL samples. Preparation involved acetonitrile precipitation, liquid-liquid extraction (hexane:ethyl acetate, 9:1), and MSTFA derivatization. An Agilent 7890 A GC was interfaced with an Agilent 7000 MS Triple Quadrupole. Selected reaction monitoring was employed. Blood samples were provided from a marijuana smoking study (two participants) and a CBD ingestion study (eight participants). Three analytes with the same transitions (THC, OH-THC and COOH-THC) were chromatographically separated. Matrix selectivity studies showed endogenous chromatographic peak area ratios (PAR) at the analyte retention times were THC, OH-THC and COOH-THC were seen; low concentrations of CBD were detected at early time points. In moderate users who had not smoked for at least 9 hours before ingesting an 800 mg oral dose of CBD, the method was sensitive enough to follow residual concentrations of THC and OH-THC; sustained COOH-THC concentrations over 50 ng/mL validated its higher analytical range. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Graphene based solid phase extraction combined with ultra high performance liquid chromatography-tandem mass spectrometry for carbamate pesticides analysis in environmental water samples.

    Science.gov (United States)

    Shi, Zhihong; Hu, Junda; Li, Qi; Zhang, Shulan; Liang, Yuhuan; Zhang, Hongyi

    2014-08-15

    In this paper, graphene, a new sorbent material, was synthesized and used for solid-phase extraction (SPE) of the six carbamate pesticides (pirimicarb, baygon, carbaryl, isoprocarb, baycarb and diethofencarb) in environmental water samples. The target analytes can be extracted on the graphene-packed SPE cartridge, and then eluted with acetone. The eluate was collected and dried by high purity nitrogen gas at room temperature. 1mL of 20% (v/v) acetonitrile aqueous solution was used to redissolve the residue. The final sample solution was analyzed by ultra performance liquid chromatography-tandem quadrupole mass spectrometry (UPLC-MS/MS) system. Under optimum conditions, good linearity was obtained for the carbamates with correlation coefficient in the range of 0.9992-0.9998. The limits of detection (S/N=3) for the six carbamate pesticides were in the range of 0.5-6.9ngL(-1). Relative standard deviations (RSD) for five replicate determinations were below 5.54%. RSD values for cartridge-to-cartridge precision (n=7) were in the range of 1.27-8.13%. After proper regeneration, the graphene-packed SPE cartridge could be re-used over 100 times for standard solution without significant loss of performance. The enrichment factors for the target analytes were in the range of 34.2-51.7. The established method has been successfully applied to the determination of carbamate pesticide residues in environmental water samples such as river water, well water and lake water. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Measurement of tissue azithromycin levels in self-collected vaginal swabs post treatment using liquid chromatography and tandem mass spectrometry (LC-MS/MS).

    Science.gov (United States)

    Vodstrcil, Lenka A; Rupasinghe, Thusitha W T; Kong, Fabian Y S; Tull, Dedreia; Worthington, Karen; Chen, Marcus Y; Huston, Wilhelmina M; Timms, Peter; McConville, Malcolm J; Fairley, Christopher K; Bradshaw, Catriona S; Tabrizi, Sepehr N; Hocking, Jane S

    2017-01-01

    Azithromycin is recommended for the treatment of uncomplicated urogenital chlamydia infection although the standard 1gram dose sometimes fails to eradicate the infection (treatment failure). One hypothesis proposed for treatment failure has been insufficient levels of the antibiotic at the site of infection. We developed an assay using liquid chromatography and tandem mass spectrometry (LC-MS/MS) to measure azithromycin concentration in high-vaginal swabs and monitor how concentration changes over time following routine azithromycin treatment. Azithromycin concentrations were measured in two groups of women either within the first 24h of taking a 1g dose (N = 11) or over 9 days (N = 10). Azithromycin concentrations were normalised to an internal standard (leucine enkephalin), and the bulk lipid species phosphatidylcholine [PC(34:1)], using an Agilent 6490 triple quadrupole instrument in positive ionisation mode. The abundances of azithromycin, PC(34:1), and leu-enkephalin were determined by multiple reaction monitoring and absolute levels of azithromycin estimated using standard curves prepared on vaginal specimens. Vaginal azithromycin concentrations of women were rapidly obtained after 5h post-treatment (mean concentration = 1031mcg/mg of lipid, range = 173-2693mcg/mg). In women followed for 9 days, peak concentrations were highest after day 2 (mean concentration = 2206mcg/mg, range = 721-5791mcg/mg), and remained high for at least 9 days with a mean concentration of 384mcg/mg (range = 139-1024mcg/mg) on day 9. Our study confirmed that a single 1g dose of azithromycin is rapidly absorbed and remains in the vagina at relatively high levels for at least a week, suggesting that poor antibiotic absorption is unlikely to be an explanation for treatment failure.

  2. Broad screening of illicit ingredients in cosmetics using ultra-high-performance liquid chromatography-hybrid quadrupole-Orbitrap mass spectrometry with customized accurate-mass database and mass spectral library.

    Science.gov (United States)

    Meng, Xianshuang; Bai, Hua; Guo, Teng; Niu, Zengyuan; Ma, Qiang

    2017-12-15

    Comprehensive identification and quantitation of 100 multi-class regulated ingredients in cosmetics was achieved using ultra-high-performance liquid chromatography (UHPLC) coupled with hybrid quadrupole-Orbitrap high-resolution mass spectrometry (Q-Orbitrap HRMS). A simple, efficient, and inexpensive sample pretreatment protocol was developed using ultrasound-assisted extraction (UAE), followed by dispersive solid-phase extraction (dSPE). The cosmetic samples were analyzed by UHPLC-Q-Orbitrap HRMS under synchronous full-scan MS and data-dependent MS/MS (full-scan MS 1 /dd-MS 2 ) acquisition mode. The mass resolution was set to 70,000 FWHM (full width at half maximum) for full-scan MS 1 and 17,500 FWHM for dd-MS 2 stage with the experimentally measured mass deviations of less than 2ppm (parts per million) for quasi-molecular ions and 5ppm for characteristic fragment ions for each individual analyte. An accurate-mass database and a mass spectral library were built in house for searching the 100 target compounds. Broad screening was conducted by comparing the experimentally measured exact mass of precursor and fragment ions, retention time, isotopic pattern, and ionic ratio with the accurate-mass database and by matching the acquired MS/MS spectra against the mass spectral library. The developed methodology was evaluated and validated in terms of limits of detection (LODs), limits of quantitation (LOQs), linearity, stability, accuracy, and matrix effect. The UHPLC-Q-Orbitrap HRMS approach was applied for the analysis of 100 target illicit ingredients in 123 genuine cosmetic samples, and exhibited great potential for high-throughput, sensitive, and reliable screening of multi-class illicit compounds in cosmetics. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. A novel scoring schema for peptide identification by searching protein sequence databases using tandem mass spectrometry data

    Directory of Open Access Journals (Sweden)

    Yu Chungong

    2006-04-01

    Full Text Available Abstract Background Tandem mass spectrometry (MS/MS is a powerful tool for protein identification. Although great efforts have been made in scoring the correlation between tandem mass spectra and an amino acid sequence database, improvements could be made in three aspects, including characterization ofpeaks in spectra, adoption of effective scoring functions and access to thereliability of matching between peptides and spectra. Results A novel scoring function is presented, along with criteria to estimate the performance confidence of the function. Through learning the typesof product ions and the probability of generating them, a hypothetic spectrum was generated for each candidate peptide. Then relative entropy was introduced to measure the similarity between the hypothetic and the observed spectra. Based on the extreme value distribution (EVD theory, a threshold was chosen to distinguish a true peptide assignment from a random one. Tests on a public MS/MS dataset demonstrated that this method performs better than the well-known SEQUEST. Conclusion A reliable identification of proteins from the spectra promises a more efficient application of tandem mass spectrometry to proteomes with high complexity.

  4. Liquid chromatography quadrupole time-of-flight mass spectrometry determination of six pharmaceuticals in vegetal biota. Uptake study in Lavandula dentata.

    Science.gov (United States)

    Barreales-Suárez, Sofía; Callejón-Mochón, Manuel; Azoulay, Stéphane; Bello-López, Miguel Ángel; Fernández-Torres, Rut

    2018-05-01

    A procedure based on microwave assisted extraction for the determination of 6 pharmaceuticals in samples of Lavandula dentata, Salicornia ramosissima and Juncus sp. by liquid chromatography-quadrupole time of flight mass spectrometry (LC-QTOF/MS) was optimized and validated. Best results were obtained using microwave assisted extraction of 1.0g of homogeneous lyophilized samples and 5mL of a mixture ACN:H 2 O (1:1 v/v) as extracting solvent. Analytical recoveries ranged from 60 to 107% with relative standard deviation (RSD) lower than 15%. Limits of quantitation (LOQ) for the 6 pharmaceuticals flumequine (FLM), carbamazepine (CBZ), ciprofloxacin (CPR), enrofloxacin (ENR), diclofenac (DCL), and ibuprofen (IBU) were in the range 20.8-125ngg -1 . The method was satisfactory applied for an uptake study in Lavandula dentata samples finding quantifying concentrations of FLM and CBZ in roots, leaf and stem. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. High-throughput screening of vitamins and natural antioxidants in nutraceuticals from green tea extracts by liquid chromatography coupled to quadrupole orbitrap mass spectrometry.

    Science.gov (United States)

    Jia, Wei; Chu, Xiaogang; Chang, James; Zhang, Feng

    2015-08-07

    A new analytical method was developed and validated for simultaneous analysis of 52 vitamins and natural antioxidants in nutraceutical products obtained from green tea (Camellia sinensis) extracts. The automated extraction procedure was achieved in a simple disposable pipet extraction. Ultra-high performance liquid chromatography and electrospray ionization quadrupole-Orbitrap high-resolution mass spectrometry (UHPLC Q-Orbitrap) was used for the separation and detection of all the analytes. The method was validated by taking into consideration the guidelines specified in European SANCO/12571/2013 Guideline 2013 and Commission Decision 2002/657/EC. The extraction recoveries were in a range of 84.9-112.7%, with coefficient of variation 0.99. This validated method has been successfully applied on screening of vitamins and natural antioxidants in 136 different commercial nutraceutical products from green tea extracts. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Tandem mass spectrometry of isomeric aniline-labeled N-glycans separated on porous graphitic carbon: Revealing the attachment position of terminal sialic acids and structures of neutral glycans.

    Science.gov (United States)

    Michael, Claudia; Rizzi, Andreas M

    2015-07-15

    Quantitative monitoring of changes in the N-glycome upon disease has gained significance in the context of biomarker discovery. Separation and quantification of isobaric glycan isomers can be attained by using high-performance liquid chromatography/electrospray ionization mass spectrometry (HPLC/ESI-MS). Collision-induced dissociation (CID)-based fragmentation of separated isobaric glycans is evaluated in respect to its potential of providing fragment ions specific for the linkage positions of terminal sialic acids and the presence of intersecting GlcNAc moieties, respectively. N-Glycans were labeled via reductive amination using (12)C6-aniline and (13)C6-aniline as isotope-coded labeling reagents. The differently labeled glycans were merged and separated into various species using a porous graphitic carbon (PGC) stationary phase. Identification of structural features of separated isobaric isomers was performed by CID-based tandem mass spectrometry (MS/MS) carried out in a quadrupole time-of-flight (QqTOF) or a quadrupole ion-trap (IT) mass spectrometer. Working in the negative ion mode, new diagnostic CID fragment ions could be found that are indicative for the α2,6-type linkage of sialic acids. Other diagnostic ions, identified before as being indicative for the substitution of the 6-antenna, could be confirmed as being of relevance also in the case of aniline labeling. In the positive ion mode, CID fragment ions indicative for the structure of short neutral N-glycans were identified. One new diagnostic ion specific for the linkage position of the terminal sialic acids and one for the presence of bisecting GlcNAc in N-glycans were identified. The aniline label introduced for improved relative quantitation in MS(1) was found not to significantly alter the CID fragmentation patterns that were reported previously by other authors for unlabeled/reduced glycans or for glycans with more polar labels. Copyright © 2015 John Wiley & Sons, Ltd.

  7. Determination of ractopamine and salbutamol in pig hair by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Chang, Kai-Chun; Chang, Yu-Ting; Tsai, Chin-En

    2018-04-01

    A liquid chromatography tandem mass spectrometric method was developed for the determination of two β-agonists (ractopamine and salbutamol) in pig hair samples. An isotope of ractopamine-d5 or salbutamol-d6 as an internal standard was used to carry out quantitative analysis. Concentrated sodium hydroxide was used to pretreat hair samples and then purified by the solid phase extraction (SPE) procedure. The extracted solution was evaporated and reconstituted for injection in the instrument with electrospray ionization (ESI) operating in a positive multiple-reaction-monitoring (MRM) mode. Ractopamine and salbutamol separation were performed on C18 analytical column under gradient condition. The internal standard calibration curve was linear in the range of concentration from 0.5 to 100 ng mL -1  (R 2  > 0.995). Recoveries of this method estimated at three spiked concentrations of 100, 250 and 500 ng mL -1 in pig hair samples, were 79-82% for ractopamine and 77-96% for salbutamol. The corresponding inter-day and intra-day precisions expressed as relative standard deviation (RSD %) were 3.8-6.4% and 3.8-8.6%, respectively. The analytical time for one sample was 8 min. The detection limit of this method was 0.6 and 8.3 ng mL -1 for ractopamine and salbutamol, respectively. This developed method can be applied for monitoring the use of the β-agonists salbutamol and ractopamine in swine feed incurred pig hair. Copyright © 2017. Published by Elsevier B.V.

  8. On-line high speed lipid extraction for nanoflow liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Lee, Ju Yong; Yang, Joon Seon; Park, Se Mi; Byeon, Seul Kee; Moon, Myeong Hee

    2016-09-16

    An on-line lipid extraction method is introduced by utilizing a short capillary extraction column using HILIC and C4 particles prior to nanoflow liquid chromatography-tandem mass spectrometry (nLC-MS/MS). The on-line extraction using a urine sample spiked with PL standards showed similar or slightly higher recovery values (86%-96%) of phospholipids (PLs) compared to those obtained by the conventional off-line extraction based on the Folch method with or without using the air-exposed drying process. In this study, we demonstrated that PL oxidation can occur during the air-exposed drying process of lipid extracts in standard liquid-liquid extraction procedures, which was confirmed by the oxidized PL (OxPL) molecules that were generated from an off-line extraction using a few PL standards. Quantitative comparison of these OxPL species between on- and off-line extraction followed by nLC-MS/MS with multiple reaction monitoring (MRM) analysis showed a significant decrease (2-10 fold) in unwanted OxPL species when on-line extraction was employed. While the number of identified PLs from a urine sample was somewhat lower than those by off-line extraction, the number of OxPLs was significantly reduced (from 70 to 22) with on-line extraction. The new method offers high speed (∼5min) automated extraction of PLs with nLC-MS/MS analysis and presents the possibility of handling a biological sample with a very limited amount of lipids. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Simultaneous quantification of Pacific ciguatoxins in fish blood using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Mak, Yim Ling; Wu, Jia Jun; Chan, Wing Hei; Murphy, Margaret B; Lam, James C W; Chan, Leo L; Lam, Paul K S

    2013-04-01

    Ciguatera fish poisoning (CFP) is a food intoxication caused by exposure to ciguatoxins (CTXs) in coral reef fish. Rapid analytical methods have been developed recently to quantify Pacific-CTX-1 (P-CTX-1) in fish muscle, but it is destructive and can cause harm to valuable live coral reef fish. Also fish muscle extract was complex making CTX quantification challenging. Not only P-CTX-1, but also P-CTX-2 and P-CTX-3 could be present in fish, contributing to ciguatoxicity. Therefore, an analytical method for simultaneous quantification of P-CTX-1, P-CTX-2, and P-CTX-3 in whole blood of marketed coral reef fish using sonication, solid-phase extraction (SPE), and liquid chromatography tandem mass spectrometry (LC-MS/MS) was developed. The optimized method gave acceptable recoveries of P-CTXs (74-103 %) in fish blood. Matrix effects (6-26 %) in blood extracts were found to be significantly reduced compared with those in muscle extracts (suppressed by 34-75 % as reported in other studies), thereby minimizing potential for false negative results. The target P-CTXs were detectable in whole blood from four coral reef fish species collected in a CFP-endemic region. Similar trends in total P-CTX levels and patterns of P-CTX composition profiles in blood and muscle of these fish were observed, suggesting a relationship between blood and muscle levels of P-CTXs. This optimized method provides an essential tool for studies of P-CTX pharmacokinetics and pharmacodynamics in fish, which are needed for establishing the use of fish blood as a reliable sample for the assessment and control of CFP.

  10. Newborn screening of inherited metabolic disorders by tandem mass spectrometry: past, present and future

    Directory of Open Access Journals (Sweden)

    G. Scaturro

    2013-04-01

    Full Text Available Inborn errors of metabolism are inherited biochemical disorders caused by lack of a functional enzyme, transmembrane transporter, or similar protein, which then results in blockage of the corresponding metabolic pathway. Taken individually, inborn errors of metabolism are rare. However, as a group these diseases are relatively frequent and they may account for most of neonatal mortality and need of health resources. The detection of genetic metabolic disorders should occur in a pre-symptomatic phase. Recently, the introduction of the tandem mass spectrometric methods for metabolite analysis has changed our ability to detect intermediates of metabolism in smaller samples and provides the means to detect a large number of metabolic disorders in a single analytical run. Screening panels now include a large number of disorders that may not meet all the criteria that have been used as a reference for years. The rationale behind inclusion or exclusion of a respective disorder is difficult to understand in most cases and it may impose an ethical dilemma. The current organization is an important tool of secondary preventive medicine, essential for children’s healthcare, but the strong inhomogeneity of the regional models of screening applied today create in the Italian neonatal population macroscopic differences with regards to healthcare, which is in effect mainly diversified by the newborn’s place of birth, in possible violation of the universal criterion of the equality of all citizens. Carefully weighed arguments are urgently needed since patient organizations, opinion leaders and politicians are pressing to proceed with expansion of neonatal population screening.

  11. Analysis of drugs of abuse in wastewater by hydrophilic interaction liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    van Nuijs, Alexander L N; Tarcomnicu, Isabela; Bervoets, Lieven; Blust, Ronny; Jorens, Philippe G; Neels, Hugo; Covaci, Adrian

    2009-10-01

    The simultaneous analysis of nine drugs of abuse (DOAs) and their metabolites (amphetamine, methamphetamine, methylenedioxymethamphetamine, methadone, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine, cocaine, benzoylecgonine, ecgonine methyl ester and 6-monoacetylmorphine) in wastewater based on hydrophilic interaction liquid chromatography (HILIC) coupled to tandem mass spectrometry (MS/MS) was optimised and validated. For each analyte, the deuterated analogue was used for quantification. The separation by HILIC showed good performance for all compounds, especially for the hydrophilic compounds, which elute early (amphetamine-like stimulants) or show no retention (ecgonine methyl ester) in reversed-phase liquid chromatography. Sample preparation based on solid-phase extraction was optimised by comparing Oasis HLB and Oasis MCX sorbents for various parameters such as sample pH, amount of sorbent bed and washing solvent. The method was validated for each compound by assessing the following parameters (following International Conference on Harmonisation guidelines): specificity, limit of quantification (LOQ), linearity, accuracy, precision, recovery and matrix effects. LOQs were 2 ng/L for 6-monoacetylmorphine, ecgonine methyl ester and amphetamine and 1 ng/L for the rest of the compounds, corresponding with the lowest point in the calibration curve. Except for 6-monoacetylmorphine, all compounds were detected from 1 to 819 ng/L in influent wastewater samples (n = 12) collected from 11 different wastewater treatment plants across Belgium. The presence of ecgonine methyl ester in wastewater could be demonstrated for the first time. In the future, the new HILIC-MS/MS method will be applied to assess the use of DOAs in Belgium using the "sewage epidemiology" approach.

  12. Identification of proteomic biomarkers of preeclampsia using protein microarray and tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Karol Charkiewicz

    2015-05-01

    Full Text Available Preeclampsia (PE is the leading cause of death of the fetus and the mother. The exact pathomechanism has not so far been clarified. PE coexists with many other diseases, but it is often difficult to explain the association between them and find a clear reason for their occurrence. There are many predictive factors, but none are highly specific in preeclampsia. The diagnosis of preeclampsia seems to be very complex, which is another argument for the exploration of knowledge on this subject. Although many of the discoveries have hitherto been made in the field of proteomics, still no single specific biomarker of preeclampsia has been discovered. Research at the genome level is important because it can help us understand the genetic predisposition of patients affected by this disease. Nevertheless, researchers have recently become more interested in the pathophysiology of PE, and they are trying to answer the question: what is the real, direct cause of preeclampsia? Thus, the discovery of a protein that is a good predictor of preeclampsia development would significantly accelerate the medical care of pregnant women, and consequently reduce the risk of occurrence of HELLP syndrome and fetal death. Apart from the predictive and diagnostic function, such a discovery would help us to better understand the pathogenesis of preeclampsia and to find in the future a medical drug to suppress this disease. In order to make a breakthrough in this field, scientists need to use the most modern methods of proteomics, which allow for the analysis of small amounts of biological material in the shortest possible time, thereby giving a lot of information about existing proteins in the sample. Such optimization allows two methods, most commonly used by researchers: tandem mass spectrometry and protein microarray technique.

  13. Applying liquid chromatography-tandem mass spectrometry to assess endodontic sealer microleakage

    Directory of Open Access Journals (Sweden)

    André Luiz da Costa MICHELOTTO

    2015-01-01

    Full Text Available The objective of this study was to describe a new method for the quantitative analysis of a microleakage of endodontic filling materials. Forty extracted single-rooted teeth were randomly divided into three experimental groups. After root canal shaping, the experimental groups were filled using the lateral condensation technique with the Epiphany system (G1, with gutta-percha + Sealapex (G2, and with gutta-percha + AH Plus (G3. Each root was mounted on a modified leakage testing device, and caffeine solution was used as a tracer (2000 ng mL-1, pH 6.0, applied in the coronal direction towards the tooth apex, creating a hydrostatic pressure of 2.55 kPa. Presence of caffeine in the receiving solution was measured after 10, 30, and 60 days, using high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS. None of the groups presented microleakage at 10 days. At 30 days, G2 and G3 showed similar infiltration patterns (means: 16.0 and 13.9 ng mL-1, respectively, whereas G1 showed significantly higher values (mean: 105.2 ng mL-1. At 60 days, leakage values were 182.6 ng mL-1for G1, 139.0 ng mL-1 for G2, and 53.5 ng mL-1 for G3. AH Plus showed the best sealing ability and HPLC-MS/MS showed high sensitivity and specificity for tracer quantification.

  14. Nitroproteins in Human Astrocytomas Discovered by Gel Electrophoresis and Tandem Mass Spectrometry

    Science.gov (United States)

    Peng, Fang; Li, Jianglin; Guo, Tianyao; Yang, Haiyan; Li, Maoyu; Sang, Shushan; Li, Xuejun; Desiderio, Dominic M.; Zhan, Xianquan

    2015-12-01

    Protein tyrosine nitration is involved in the pathogenesis of highly fatal astrocytomas, a type of brain cancer. To understand the molecular mechanisms of astrocytomas and to discover new biomarkers/therapeutic targets, we sought to identify nitroproteins in human astrocytoma tissue. Anti-nitrotyrosine immunoreaction-positive proteins from a high-grade astrocytoma tissue were detected with two-dimensional gel electrophoresis (2DGE)-based nitrotyrosine immunoblots, and identified with liquid chromatography-tandem mass spectrometry (LC-MS/MS). Fifty-seven nitrotyrosine immunopositive protein spots were detected. A total of 870 proteins (nitrated and non-nitrated) in nitrotyrosine-immunopositive 2D gel spots were identified, and 18 nitroproteins and their 20 nitrotyrosine sites were identified with MS/MS analysis. These nitroproteins participate in multiple processes, including drug-resistance, signal transduction, cytoskeleton, transcription and translation, cell proliferation and apoptosis, immune response, phenotypic dedifferentiation, cell migration, and metastasis. Among those nitroproteins that might play a role in astrocytomas was nitro-sorcin, which is involved in drug resistance and metastasis and might play a role in the spread and treatment of an astrocytoma. Semiquantitative immune-based measurements of different sorcin expressions were found among different grades of astrocytomas relative to controls, and a semiquantitative increased nitration level in high-grade astrocytoma relative to control. Nitro-β-tubulin functions in cytoskeleton and cell migration. Semiquantitative immunoreactivity of β-tubulin showed increased expression among different grades of astrocytomas relative to controls and semiquantitatively increased nitration level in high-grade astrocytoma relative to control. Each nitroprotein was rationalized and related to the corresponding functional system to provide new insights into tyrosine nitration and its potential role in the

  15. Ion Mobility and Tandem Mass Spectrometry of Phosphatidylglycerol and Bis(monoacylglycerol)phosphate (BMP)

    Science.gov (United States)

    Hankin, Joseph A.; Murphy, Robert C.; Barkley, Robert M.; Gijón, Miguel A.

    2014-01-01

    The tandem mass spectrometry, ion mobility, and normal phase HPLC of isomeric phosphatidylglycerol (PG) and bis(monoacylglycerol)phosphate (BMP) have been investigated in this study with the objective of differentiating these unique classes of lipids. Measurement of ion mobility using the traveling wave method for negative molecular and product ions from isomeric PG and BMP yielded identical results, but different ion mobilities were observed for positive product ions arising from collision-induced dissociation (CID). The fastest moving positive product ions from the ion mobility analysis of BMP(18:1/18:1) were monoglyceride-like, and the slowest moving product ions from this BMP corresponded to [M+H-2H2O]+, which were readily observed for BMP but were only at very low abundance in the CID spectra of PG. The major product ions observed from the sodium adduct of PG(18:1/18:1) were consistent with diglyceride-like ion formation, but for BMP(18:1/18:1) only monoglyceride-like product ions were formed. The usefulness of ion mobility separation was tested with the selection of positive product ions derived from the isomeric PG and BMP molecular species in the lipid extract of RAW 264.7 cells. The ion mobility spectra of monoglyceride-like ions derived from BMP species with various esterified fatty acyl groups displayed some separation in ion mobility based on fatty acyl chain length and presence of a double bond in the acyl chain. The mechanism of ion formation of the diglyceride- and monoglyceride-like ions from PG and BMP respectively was examined using deuterium-labeled species including PG(D3116:0/18:1) and PG and BMP labeled by deuterium exchange. PMID:25883529

  16. Validated method for determination of mazindol in human plasma by liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Kim, Sung-Su; Lee, Heon-Woo; Lee, Kyung-Tae

    2009-04-01

    A simple liquid chromatography/tandem mass spectrometry (LC/MS/MS) method with electrospray ionization in positive ion multiple reaction monitoring mode was developed for the quantification of mazindol (an anorectic agent) in human plasma. Fluoxetine was adopted as an internal standard (IS), and sample preparation involved one-step liquid/liquid extraction using ethyl acetate. The transition monitored were m/z 285>44 for mazindol and m/z 310>44 for IS. Chromatographic separation was achieved on a Capcell Pak MGII C(18) column using an isocratic mobile phase, consisting of acetonitrile-20mM ammonium formate in water (50:50, v/v, adjusted to pH 3.5 with formic acid) at a flow-rate of 0.2mL/min. The retention times of mazindol and fluoxetine were 1.03min and 1.45min, respectively. The lower limit of quantitation (LLOQ) was 0.1ng/mL using 200microL of plasma, and no interferences were detected in chromatograms. The bench top stability of mazindol was evaluated in buffered and non-buffered plasma. The selectivity, linearity, precision, accuracy, recovery, and stability of the devised method were fully validated and absolute and relative matrix effects were evaluated. The described method provides a fast and sensitive analytical tool for determining mazindol levels in plasma, and was successfully applied to a pharmacokinetic study in 24 healthy human subjects after oral administration of 2mg tablet formulation of mazindol under fasting conditions.

  17. Determination of spinetoram in leafy vegetable crops using liquid chromatography and confirmation via tandem mass spectrometry.

    Science.gov (United States)

    Liu, Xue; Abd El-Aty, A M; Park, Ji-Yeon; Park, Jong-Hyouk; Cho, Soon-Kil; Shin, Ho-Chul; Shim, Jae-Han

    2011-10-01

    Spinetoram is a second-generation member of the spinosyn class, all members of which have been shown to be effective in insect control via a novel mode of action. Spinetoram is a mixture of 3'-O-ethyl-5, 6-dihydro spinosyn J (XDE-175-J) and 3'-O-ethyl spinosyn L (XDE-175-L). In order to establish a determination method for the analysis of spinetoram residues in crops, commercial product (5% suspension concentrate spinetoram) was applied to two leafy vegetables (Garland chrysanthemum and Aster scaber) on different spraying schedules. The analytical method used herein was based on a reversed-phase separation on a C(18) column, isocratic elution and UV detection. The analytes were confirmed via tandem mass spectrometry. The method was linear over a concentration range of 0.05-10 ppm with a correlation coefficient in excess of 0.9998. The recoveries of XDE-175-J and XDE-175-L from the two vegetables ranged between 86.04 and 98.87% at spiking levels of 1 and 5 ppm. The relative standard deviations were no more than 7% for all recovery tests conducted herein. The calculated limits of detection and quantification were 0.01 and 0.03 ppm for both XDE-175-J and XDE-175-L. The levels of residues in two vegetables treated under a fixed schedule in the greenhouse were 6.21-0.55 ppm (maximum residue limit (MRL) = 7 ppm). In sum, this method constitutes an easy and reliable technique for the determination of spinetoram in leafy vegetables. Copyright © 2011 John Wiley & Sons, Ltd.

  18. Deriving the probabilities of water loss and ammonia loss for amino acids from tandem mass spectra.

    Science.gov (United States)

    Sun, Shiwei; Yu, Chungong; Qiao, Yantao; Lin, Yu; Dong, Gongjin; Liu, Changning; Zhang, Jingfen; Zhang, Zhuo; Cai, Jinjin; Zhang, Hong; Bu, Dongbo

    2008-01-01

    In protein identification through tandem mass spectrometry, it is critical to accurately predict the theoretical spectrum for a peptide sequence. The widely used prediction models, such as SEQUEST and MASCOT, ignore the intensity of the ions with important neutral losses, including water loss and ammonia loss. However, ignoring these neutral losses results in a significant deviation between the predicted theoretical spectrum and its experimental counterpart. Here, based on the "one peak, multiple explanations" observation, we proposed an expectation-maximization (EM) method to automatically learn the probabilities of water loss and ammonia loss for each amino acid. Then we employed these probabilities to design an improved statistical model for theoretical spectrum prediction. We implemented these methods and tested them on practical data. On a training set containing 1803 spectra, the experimental results show a good agreement with some known knowledge about neutral losses, such as the tendency of water loss from Asp, Glu, Ser, and Thr. Furthermore, on a testing set containing 941 spectra, the improved similarity between the experimental and predicted spectra demonstrates that this method can generate more reasonable predictions relative to the model that ignores neutral losses. As an application of the derived probabilities, we implemented a database searching method adopting the improved theoretical spectrum model with neutral loss ions estimated. Experimental results on Keller's data set demonstrate that this method can identify peptides more accurately than SEQUEST. In another application to validate SEQUEST's results, the reported peptide-spectrum pairs are reranked with respect to the similarity between experimental and predicted spectra. Experimental results on both LTQ and QSTAR data sets suggest that this reranking strategy can effectively distinguish the false negative predictions reported by SEQUEST.

  19. Rapid determination of 18 glucocorticoids in serum using reusable on-line SPE polymeric monolithic column coupled with LC-quadrupole/orbitrap high-resolution mass spectrometer.

    Science.gov (United States)

    Li, Hui; Ai, Lianfeng; Fan, Sufang; Wang, Yan; Sun, Dianxing

    2017-10-15

    A simple, rapid and sensitive method for the simultaneous determination of 18 glucocorticoids in serum was developed by coupling on-line solid-phase extraction (SPE) polymeric monolithic column to a liquid chromatography-quadrupole/orbitrap high-resolution mass spectrometer. A simple poly(ethylene glycol dimethacrylate) monolith column (10mm×2.1mm i.d.) was fabricated, and the morphology, surface area and extraction performance of the monolithic column were characterized. Serum samples were extracted by acetonitrile (ACN). Then, online SPE was achieved on the synthesized monolithic column using a 10mmol/L ammonium acetate solution as the loading solvent. After the transfer from the monolith into analytical column (Capcell Pak ADME column) using ACN, the adsorbed analytes were separated on the analytical column and detected with a high-resolution hybrid quadrupole/orbitrap mass spectrometer with full scan/ddMS 2 scan mode Under optimized conditions, the method was linear with target linear correlation coefficient (R 2 ) higher than 0.995. Detection limits were in range of 0.1-0.6ng/mL, and the quantification limits were 0.3-1.5ng/mL. The recovery was between 71.9% and 89.2% in three spike levels with precision (n=5) of 5.40-12.1%. The serum sample was directly analyzed after a simple extraction procedure, and the on-line SPE and determination were achieved within only 16min. The method was used to analyze the dynamic contents variation of cortisone and hydrocortisone in serum before and after the surgery. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Optimization of a liquid chromatography-tandem mass spectrometry method for quantification of the plant lignans secoisolariciresinol, matairesinol, lariciresinol and pinoresinol in foods

    NARCIS (Netherlands)

    Milder, I.E.J.; Arts, I.C.W.; Venema, D.P.; Lasaroms, J.J.P.; Wähälä, K.; Hollman, P.C.H.

    2004-01-01

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the quantification of the four major enterolignan precursors [secoisolariciresinol, matairesinol, lariciresinol, and pinoresinol] in foods. The method consists of alkaline methanolic extraction, followed by

  1. Thermogravimetry coupled to single photon ionization quadrupole mass spectrometry: a tool to investigate the chemical signature of thermal decomposition of polymeric materials.

    Science.gov (United States)

    Saraji-Bozorgzad, M; Geissler, R; Streibel, T; Mühlberger, F; Sklorz, M; Kaisersberger, E; Denner, T; Zimmermann, R

    2008-05-01

    Mass spectrometry (MS) is an established analytical technique to analyze evolved gas in thermogravimetry (TG). In this study, for the first time a novel SPI-MS technique using an electron beam pumped VUV excimer lamp as photon source (lambda = 126 nm) was employed in conjunction with thermogravimetry. The coupling was achieved with an improved heated interface and adjacent transfer capillary between TG and ion source of a quadrupole mass spectrometer. The feasibility of this approach was proven by investigating semivolatile substances such as long-chain alkanes (heptadecane C17H36), polymers, e.g., polystyrene, polycarbonate, and acrylonitrile-butadiene-styrene, polymer mixtures and blends. Mass spectra with almost no fragmentation were obtained, and quantification of selected substances could be achieved. Polymer mixtures could be distinguished by their SPI mass spectra, and the effect of premixing of polymers has been accessed. Its unique attributes render the TA-SPI-MS method a promising new tool for quantitative and qualitative evaluation of complex organic thermal degradation products.

  2. A practical strategy for the characterization of coumarins in Radix Glehniae by liquid chromatography coupled with triple quadrupole-linear ion trap mass spectrometry.

    Science.gov (United States)

    Yang, Wei; Ye, Min; Liu, Man; Kong, Dezhi; Shi, Rui; Shi, Xiaowei; Zhang, Kerong; Wang, Qiao; Lantong, Zhang

    2010-07-02

    The aim of the present study was to develop a practical method for the characterization of coumarins in Radix Glehniae by liquid chromatography-mass spectrometry (LC-MS). First, 10 coumarin standards (including two pairs of isomers) were studied, and mass spectrometry fragmentation patterns and elution time rules for the coumarins were found. Then, an extract of Radix Glehniae was analyzed by the combination of two scan modes, i.e., multiple ion monitoring-information-dependent acquisition-enhanced product ion mode (MIM-IDA-EPI) and precursor scan information-dependent acquisition-enhanced product ion mode (PREC-IDA-EPI) on a hybrid triple quadrupole-linear ion trap mass spectrometer. A total of 41 coumarins were identified on the basis of their mass spectrometry fragmentation patterns. This is the first time that these two scan modes have been combined to characterize chemical constituents in traditional Chinese medicine. This new method allowed the identification of coumarins in Radix Glehniae in trace amounts. The methodology proposed in this study could be valuable for the structural characterization of coumarins from complex natural and synthetic sources. Copyright 2010 Elsevier B.V. All rights reserved.

  3. Non-targeted acquisition strategy for screening doping compounds based on GC-EI-hybrid quadrupole-Orbitrap mass spectrometry: A focus on exogenous anabolic steroids.

    Science.gov (United States)

    de Albuquerque Cavalcanti, Gustavo; Rodrigues, Lucas Martins; Dos Santos, Leonardo; Zheng, Xin; Gujar, Amit; Cole, Jason; Padilha, Monica Costa; de Aquino Neto, Francisco Radler

    2018-03-01

    This is a first look at a non-targeted screening method based on Orbitrap gas chromatography-mass spectrometry (GC-MS) technology for a large number of banned compounds in sports found in urine, including exogenous anabolic steroids, β-agonists, narcotics, stimulants, hormone modulators, and diuretics. A simple sample preparation was processed in four steps: an enzymatic hydrolysis, liquid-liquid extraction, evaporation, and trimethylsilylation. All compounds were able to meet the World Anti-Doping Agency's sensitivity criteria with mass accuracies less than 1 ppm and with sufficient points across the peak by running the Orbitrap GC-MS in full-scan mode. In addition, we discuss our initial findings of using a full-scan selected ion monitoring-tandem mass spectrometry (SIM-MS/MS) approach as a way to obtain lower detection limits and reach desirable selectivity for some exogenous anabolic steroids. Copyright © 2017 John Wiley & Sons, Ltd.

  4. Analysis of a series of chlorogenic acid isomers using differential ion mobility and tandem mass spectrometry.

    Science.gov (United States)

    Willems, Jamie L; Khamis, Mona M; Mohammed Saeid, Waleed; Purves, Randy W; Katselis, George; Low, Nicholas H; El-Aneed, Anas

    2016-08-24

    Chlorogenic acids are among the most abundant phenolics found in the human diet. Of these, the mono-caffeoylquinic acids are the predominant phenolics found in fruits, such as apples and pears, and products derived from them. In this research, a comprehensive study of the electrospray ionization (ESI) tandem mass spectrometric (MS/MS) dissociation behavior of the three most common mono-caffeoylquinic acids, namely 5-O-caffeoylquinic acid (5-CQA), 3-O-caffeoylquinic acid (3-CQA) and 4-O-caffeoylquinic acid (4-CQA), were determined using both positive and negative ionization. All proposed structures of the observed product ions were confirmed with second-generation MS(3) experiments. Similarities and differences between the dissociation pathways in the positive and negative ion modes are discussed, confirming the proposed structures and the established MS/MS fingerprints. MS/MS dissociation was primarily driven via the cleavage of the ester bond linking the quinic acid moiety to the caffeic acid moiety within tested molecules. Despite being structural isomers with the same m/z values and dissociation behaviors, the MS/MS data in the negative ion mode was able to differentiate the three isomers based on ion intensity for the major product ions, observed at m/z 191, 179 and 173. This differentiation was consistent among various MS instruments. In addition, ESI coupled with high-field asymmetric waveform ion mobility spectrometry-mass spectrometry (ESI-FAIMS-MS) was employed for the separation of these compounds for the first time. By combining MS/MS data and differential ion mobility, a method for the separation and identification of mono-caffeoylquinic in apple/pear juice samples was developed with a run time of less than 1 min. It is envisaged that this methodology could be used to identify pure juices based on their chlorogenic acid profile (i.e., metabolomics), and could also be used to detect juice-to-juice adulteration (e.g., apple juice addition to pear juice

  5. Quantification of Galactose-1-Phosphate Uridyltransferase Enzyme Activity by Liquid Chromatography–Tandem Mass Spectrometry

    Science.gov (United States)

    Li, Yijun; Ptolemy, Adam S.; Harmonay, Lauren; Kellogg, Mark; Berry, Gerard T.

    2013-01-01

    Background The diagnosis of galactosemia usually involves the measurement of galactose-1-phosphate uridyltransferase (GALT) activity. Traditional radioactive and fluorescent GALT assays are nonspecific, laborious, and/or lack sufficient analytical sensitivity. We developed a liquid chromatography–tandem mass spectrometry (LC-MS/MS)–based assay for GALT enzyme activity measurement. Method Our assay used stable isotope-labeled α-galactose-1-phosphate ([13C6]-Gal-1-P) as an enzyme substrate. Sample cleanup and separation were achieved by reversed-phase ion-pair chromatography, and the enzymatic product, isotope-labeled uridine diphosphate galactose ([13C6]-UDPGal), was detected by MS/MS at mass transition (571 > 323) and quantified by use of [13C6]-Glu-1-P (265 > 79) as an internal standard. Results The method yielded a mean (SD) GALT enzyme activity of 23.8 (3.8) µmol · (gHgb)−1 · h−1 in erythrocyte extracts from 71 controls. The limit of quantification was 0.04 µmol · (g Hgb)−1 · h−1 (0.2% of normal control value). Intraassay imprecision was determined at 4 different levels (100%, 25%, 5%, and 0.2% of the normal control values), and the CVs were calculated to be 2.1%, 2.5%, 4.6%, and 9.7%, respectively (n = 3). Interassay imprecision CVs were 4.5%, 6.7%, 8.2%, and 13.2% (n = 5), respectively. The assay recoveries at the 4 levels were higher than 90%. The apparent Km of the 2 substrates, Gal-1-P and UDPGlc, were determined to be 0.38 mmol/L and 0.071 mmol/L, respectively. The assay in erythrocytes of 33 patients with classical galactosemia revealed no detectable activity. Conclusions This LC-MS/MS–based assay for GALT enzyme activity will be useful for the diagnosis and study of biochemically heterogeneous patients with galactosemia, especially those with uncommon genotypes and detectable but low residual activities. PMID:20348403

  6. Quantification of galactose-1-phosphate uridyltransferase enzyme activity by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Li, Yijun; Ptolemy, Adam S; Harmonay, Lauren; Kellogg, Mark; Berry, Gerard T

    2010-05-01

    The diagnosis of galactosemia usually involves the measurement of galactose-1-phosphate uridyltransferase (GALT) activity. Traditional radioactive and fluorescent GALT assays are nonspecific, laborious, and/or lack sufficient analytical sensitivity. We developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based assay for GALT enzyme activity measurement. Our assay used stable isotope-labeled alpha- galactose-1-phosphate ([(13)C(6)]-Gal-1-P) as an enzyme substrate. Sample cleanup and separation were achieved by reversed-phase ion-pair chromatography, and the enzymatic product, isotope-labeled uridine diphosphate galactose ([(13)C(6)]-UDPGal), was detected by MS/MS at mass transition (571 > 323) and quantified by use of [(13)C(6)]-Glu-1-P (265 > 79) as an internal standard. The method yielded a mean (SD) GALT enzyme activity of 23.8 (3.8) mumol x (g Hgb)(-1) x h(-1) in erythrocyte extracts from 71 controls. The limit of quantification was 0.04 micromol x (g Hgb)(-1) x h(-1) (0.2% of normal control value). Intraassay imprecision was determined at 4 different levels (100%, 25%, 5%, and 0.2% of the normal control values), and the CVs were calculated to be 2.1%, 2.5%, 4.6%, and 9.7%, respectively (n = 3). Interassay imprecision CVs were 4.5%, 6.7%, 8.2%, and 13.2% (n = 5), respectively. The assay recoveries at the 4 levels were higher than 90%. The apparent K(m) of the 2 substrates, Gal-1-P and UDPGlc, were determined to be 0.38 mmol/L and 0.071 mmol/L, respectively. The assay in erythrocytes of 33 patients with classical galactosemia revealed no detectable activity. This LC-MS/MS-based assay for GALT enzyme activity will be useful for the diagnosis and study of biochemically heterogeneous patients with galactosemia, especially those with uncommon genotypes and detectable but low residual activities.

  7. Preferential alkali metal adduct formation by cis geometrical isomers of dicaffeoylquinic acids allows for efficient discrimination from their trans isomers during ultra-high-performance liquid chromatography/quadrupole time-of-flight mass spectrometry

    CSIR Research Space (South Africa)

    Makola, MM

    2016-03-01

    Full Text Available discrimination of the geometrical isomers of these molecules has proven to be an elusive task. UV-irradiated methanolic solutions of diCQA were analyzed using an ultra-high-performance liquid chromatography/quadrupole time-of-flight mass spectrometry (UHPLC...

  8. Quantitative analysis of hindered amine li