  1. Assessment of diagnosing metastatic bone tumor on T2*-weighted images. Comparison between turbo spin echo (TSE) method and gradient echo (GE) method

    International Nuclear Information System (INIS)

    Hayashi, Takahiko; Sugiyama, Akira; Katayama, Motoyuki

    1996-01-01

    We examined the usefulness of T2 * weighted gradient field echo images for diagnosis for metastatic bone tumors in comparison with T2 weighted turbo spin echo (fast spin echo) images. In T2 * weighted gradient field echo sequence to obtain maximum contrast-to-noise ratio (CNR), we experimentally manipulated flip angle (FA) (5deg-90deg), repetition time (TR) (400, 700 msec), and echo time (TE) (10-50 msec). The best CNR was 16.4 in fast low angle shot (FLASH) (TE: 24 msec, TR: 700 msec, FA: 40deg). Magnetic resonance imaging was carried out in 28 patients with metastatic bone tumors. In addition to conventional T1 weighted spin echo images, T2 weighted turbo spin echo (fast spin echo images) and T2 * weighted gradient field echo images were obtained. T2 * weighted gradient field echo images were superior to T2 weighted turbo spin echo (fast spin echo) images in delineating the tumors, adjacent fat tissues, and bone marrow. (author)

  2. Optimal MR pulse sequences for hepatic hemangiomas : comparison of T2-weighted turbo-spin-echo, T2-weighted breath-hold turbo-spin-echo, and T1-weighted FLASH dynamic imaging

    International Nuclear Information System (INIS)

    Wang, Wen Chao; Choi, Byung Ihn; Han, Joon Koo; Kim, Tae Kyoung; Cho, Soon Gu

    1997-01-01

    To optimize MR imaging pulse sequences in the imaging of hepatic hemangioma and to evaluate on dynamic MR imaging the enhancing characteristics of the lesions. Twenty patients with 35 hemangiomas were studied by using Turbo-spin-echo (TSE) sequence (T2-weighted, T2- and heavily T2-weighted breath-hold) and T1-weighted FLASH imaging acquired before, immediately on, and 1, 3 and 5 minutes after injection of a bolus of Gd-DTPA (0.1mmol/kg). Phased-array multicoil was employed. Images were quantitatively analyzed for lesion-to-liver signal difference to noise ratios (SD/Ns), and lesion-to-liver signal ratios (H/Ls), and qualitatively analyzed for lesion conspicuity. The enhancing characteristics of the hemangiomas were described by measuring the change of signal intensity as a curve in T1-weighted FLASH dynamic imaging. For T2-weighted images, breath-hold T2-weighted TSE had a slightly higher SD/N than other pulse sequences, but there was no statistical difference in three fast pulse sequences (p=0.211). For lesion conspicuity, heavily T2-weighted breath-hold TSE images was superior to T2-weighted breath-hold or non-breath-hold TSE (H/L, 5.75, 3.81, 2.87, respectively, p<0.05). T2-weighted breath-hold TSE imaging was more effective than T2-weighted TSE imaging in removing lesion blurring or lack of sharpness, and there was a 12-fold decrease in acquisition time (20sec versus 245 sec). T1-weighted FLASH dynamic images of normal liver showed peak enhancement at less than 1 minute, and of hemangioma at more than 3 minutes;the degree of enhancement for hemangioma decreased after a 3 minute delay. T2-weighed breath-hold TSE imaging and Gd-DTPA enhanced FLASH dynamic imaging with 5 minutes delay are sufficient for imaging hepatic hemangiomas

  3. Usefulness of fluid attenuated inversion recovery(FLAIR) image in mesial temporal sclerosis : comparison with turbo spin-echo T2-weighted image

    Energy Technology Data Exchange (ETDEWEB)

    Son, Seok Hyun; Chang, Seung Kuk; Eun, Choong Ki [Pusan Paik Hospital, Inje Univ. College of Medicine, Kimhae (Korea, Republic of)

    1999-12-01

    To determine the usefulness of fluid attenuated inversion recovery(FLAIR) imaging for the in detection of high signal intensity of hippocampus or amygdala in mesial temporal sclerosis (MTS), compared with that of turbo spin-echo T2-weighted imaging. Two neuroradiologists independently analyzed randomly mixed MR images of 20 lesions of 17 patients in whom MTS had been diagnosed, and ten normal controls. All subjects underwent both who performed both FLAIR and turbo spin-echo T2-weighted imaging, in a blind fashion. In order to determine hippocampal morphology, oblique coronal images perpendicular to the long axis of the hippocampus were obtained. The detection rate of high signal intensity in hippocampus or amygdala, the radiologists' preferred imaging sequence, and intersubject consistency of detection were evaluated. Signal intensity in hippocampus or amygdala was considered high if substantially higher than signal intensity in the cortex of adjacent temporo-parietal lobe. In all normal controls, FLAIR and spin-echo T2-weighted images showed normal signal intensity in hippocampus or amygdala. In MTS, the mean detection rate of high signal intensity in hippocampus or amygdala, as seen on FLAIR images was 93%, compared with 43% on spin-echo T2-weighted images. In all cases in which signal intensity on FLAIR images was normal, signal intensity on spin-echo T2-weighted images was also normal. The radiologists preferred the contrast properties of FLAIR to those of spin-echo T2-weighted images. In the diagnosis of MTS using MRI, FLAIR images are more useful for the detection of high signal intensity of hippocampus or amygdala than are spin-echo T2-weighted images. In the diagnosis of MTS, FLAIR imaging is therefore a suitable alternative to spin-echo T2-weighted imaging.

  4. Usefulness of fluid attenuated inversion recovery(FLAIR) image in mesial temporal sclerosis : comparison with turbo spin-echo T2-weighted image

    International Nuclear Information System (INIS)

    Son, Seok Hyun; Chang, Seung Kuk; Eun, Choong Ki

    1999-01-01

    To determine the usefulness of fluid attenuated inversion recovery(FLAIR) imaging for the in detection of high signal intensity of hippocampus or amygdala in mesial temporal sclerosis (MTS), compared with that of turbo spin-echo T2-weighted imaging. Two neuroradiologists independently analyzed randomly mixed MR images of 20 lesions of 17 patients in whom MTS had been diagnosed, and ten normal controls. All subjects underwent both who performed both FLAIR and turbo spin-echo T2-weighted imaging, in a blind fashion. In order to determine hippocampal morphology, oblique coronal images perpendicular to the long axis of the hippocampus were obtained. The detection rate of high signal intensity in hippocampus or amygdala, the radiologists' preferred imaging sequence, and intersubject consistency of detection were evaluated. Signal intensity in hippocampus or amygdala was considered high if substantially higher than signal intensity in the cortex of adjacent temporo-parietal lobe. In all normal controls, FLAIR and spin-echo T2-weighted images showed normal signal intensity in hippocampus or amygdala. In MTS, the mean detection rate of high signal intensity in hippocampus or amygdala, as seen on FLAIR images was 93%, compared with 43% on spin-echo T2-weighted images. In all cases in which signal intensity on FLAIR images was normal, signal intensity on spin-echo T2-weighted images was also normal. The radiologists preferred the contrast properties of FLAIR to those of spin-echo T2-weighted images. In the diagnosis of MTS using MRI, FLAIR images are more useful for the detection of high signal intensity of hippocampus or amygdala than are spin-echo T2-weighted images. In the diagnosis of MTS, FLAIR imaging is therefore a suitable alternative to spin-echo T2-weighted imaging

  5. T2-weighted MR imaging of liver lesions: a prospective evaluation comparing turbo spin-echo, breath-hold turbo spin-echo and half-Fourier turbo spin-echo (HASTE) sequences

    International Nuclear Information System (INIS)

    Martin, J.; Villajos, M.; Oses, M. J.; Veintemillas, M.; Rue, M.; Puig, J.; Sentis, M.

    2000-01-01

    To compare turbo spin-echo (TSE), breath-hold TSE and half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequences quantitatively and qualitatively in T2-weighted images of liver lesions. The authors evaluated prospectively 89 liver lesions in 73 patients using a 1.0-T magnetic resonance system to compare TSE, breath-hold TSE and HASTE sequences. The quantitative parameters were: lesion-to-liver contrast and lesion-to-liver contrast-to-noise ratio. The qualitative analysis was performed by two observers in consensus who examined four parameters: respiratory artifacts, lesion edge definition, intrahepatic vessel definition and image quality. Repeated measures analysis of variance was utilized to compare the quantitative variables and Friedman's nonparametric test for the qualitative parameters. In quantitative terms, the lesion-to-liver contrast was similar in TSE and breath-hold TSE sequences (2.45±1.44 versus 2.60±1.66), both of which were significantly better than the HASTE sequence (1.12±0.72; p<0.001). The lesion-to-liver contrast-to-noise ratio was significantly higher in the TSE sequence (62.60±46.40 versus 40.22±25.35 versus 50.90±32.10 for TSE, breath-hold TSE and HASTE sequences, respectively; p<0.001). In the qualitative comparisons, the HASTE sequence was significantly better than the TSE and breath-hold TSE sequences (p<0.001) in terms of artifacts and definition of lesion edge and intrahepatic vessels. Image quality was also significantly greater in the HASTE sequence (p<0.001). In quantitative terms, the TSE sequence is better than the breath-hold TSE and HASTE sequences, but there are no movement artifacts in the HASTE sequence, which is also significantly superior to TSE and breath-hold TSE sequences in qualitative terms and, thus, can be employed for T2-weighted images in liver studies. (Author) 17 refs

  6. Contrast-enhanced Magnetic Resonance Imaging of Pelvic Bone Metastases at 3.0 T: Comparison Between 3-dimensional T1-weighted CAIPIRINHA-VIBE Sequence and 2-dimensional T1-weighted Turbo Spin-Echo Sequence.

    Science.gov (United States)

    Yoon, Min A; Hong, Suk-Joo; Lee, Kyu-Chong; Lee, Chang Hee

    2018-06-12

    This study aimed to compare 3-dimensional T1-weighted gradient-echo sequence (CAIPIRINHA-volumetric interpolated breath-hold examination [VIBE]) with 2-dimensional T1-weighted turbo spin-echo sequence for contrast-enhanced magnetic resonance imaging (MRI) of pelvic bone metastases at 3.0 T. Thirty-one contrast-enhanced MRIs of pelvic bone metastases were included. Two contrast-enhanced sequences were evaluated for the following parameters: overall image quality, sharpness of pelvic bone, iliac vessel clarity, artifact severity, and conspicuity and edge sharpness of the smallest metastases. Quantitative analysis was performed by calculating signal-to-noise ratio and contrast-to-noise ratio of the smallest metastases. Significant differences between the 2 sequences were assessed. CAIPIRINHA-VIBE had higher scores for overall image quality, pelvic bone sharpness, iliac vessel clarity, and edge sharpness of the metastatic lesions, and had less artifacts (all P 0.05). Our results suggest that CAIPIRINHA-VIBE may be superior to turbo spin-echo for contrast-enhanced MRI of pelvic bone metastases at 3.0 T.

  7. Endometrial cancer: preoperative staging using three-dimensional T2-weighted turbo spin-echo and diffusion-weighted MR imaging at 3.0 T: a prospective comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Hori, Masatoshi; Kim, Tonsok; Onishi, Hiromitsu; Nakamoto, Atsushi; Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Radiology, Suita, Osaka (Japan); Imaoka, Izumi; Kagawa, Yuki; Murakami, Takamichi [Kinki University School of Medicine, Department of Radiology, Osaka (Japan); Ueguchi, Takashi; Tatsumi, Mitsuaki [Osaka University Hospital, Department of Radiology, Osaka (Japan); Enomoto, Takayuki [Osaka University Graduate School of Medicine, Department of Obstetrics and Gynecology, Osaka (Japan); Niigata University School of Medicine, Department of Obstetrics and Gynecology, Niigata (Japan); Kimura, Tadashi [Osaka University Graduate School of Medicine, Department of Obstetrics and Gynecology, Osaka (Japan)

    2013-08-15

    To prospectively assess the efficacy of 3-T magnetic resonance (MR) imaging using the three-dimensional turbo spin-echo T2-weighted and diffusion-weighted technique (3D-TSE/DW) compared with that of conventional imaging using the two-dimensional turbo spin-echo T2-weighted and dynamic contrast-enhanced technique (2D-TSE/DCE) for the preoperative staging of endometrial cancer, with pathological analysis as the reference standard. Seventy-one women with endometrial cancer underwent MR imaging using 3D-TSE/DW (b = 1,000 s/mm{sup 2}) and 2D-TSE/DCE. Two radiologists independently assessed the two imaging sets. Accuracy, sensitivity, and specificity for staging were analysed with the McNemar test; the areas under the receiver operating characteristic curve (Az) were compared with a univariate z-score test. The results for assessing deep myometrial invasion, accuracy, sensitivity, specificity and Az, respectively, were as follows: 3D-TSE/DW - observer 1, 87 %, 95 %, 85 % and 0.96; observer 2, 92 %, 84 %, 94 % and 0.95; 2D-TSE/DCE - observer 1, 80 %, 79 %, 81 % and 0.89; observer 2, 86 %, 84 %, 87 % and 0.86. Most of the values were higher with 3D-TSE/DW without significant differences (P > 0.12). For assessing cervical stromal invasion, there were no significant differences in those values for both observers (P > 0.6). Accuracy of 3D-TSE/DW was at least equivalent to that of the conventional technique for the preoperative assessment of endometrial cancer. (orig.)

  8. [The use of the T2-weighted turbo-spin-echo sequence in studying the neurocranium. A comparison with the conventional T2-weighted spin-echo sequence].

    Science.gov (United States)

    Siewert, C; Hosten, N; Felix, R

    1994-07-01

    T2-weighted spin-echo imaging is the standard screening procedure in MR imaging of the neurocranium. We evaluated fast spin-echo T2-weighted imaging (TT2) of the neurocranium in comparison to conventional spin-echo T2-weighted imaging (T2). Signal-to-noise and contrast-to-noise ratio of normal brain tissues (basal ganglia, grey and white matter, CSF fluid) and different pathologies were calculated. Signal-to-noise ratio and contrast-to-noise ratio were significantly higher in TT2 than in T2 (with the exception of gray-to-white matter contrast). Tissues with increased content of water protons (mobile protons) showed the highest contrast to surrounding tissues. The increased signal intensity of fat must be given due attention in fatty lesions. Because the contrast-to-noise ratio between white matter and basal ganglia is less in TT2, Parkinson patients have to be examined by conventional T2. If these limitations are taken into account, fast spin-echo T2-weighted imaging is well appropriate for MR imaging of the neurocranium, resulting in heavy T2-weighting achieved in a short acquisition time.

  9. T2-weighted MR imaging of liver lesions: a prospective evaluation comparing turbo spin-echo, breath-hold turbo spin-echo and half-Fourier turbo spin-echo (HASTE) sequences; Estudio de lesiones hepaticas con imagenes de resonancia magnetica potenciadas en T2: evaluacion prospectiva comparando secuencias turbo eco del espin, turbo eco del espin con respiracion sostenida y half-Fourier turbo eco del espin (HASTE)

    Energy Technology Data Exchange (ETDEWEB)

    Martin, J.; Villajos, M.; Oses, M. J.; Veintemillas, M.; Rue, M.; Puig, J.; Sentis, M. [Fundacion Parc Tauli. Sabadell (Spain)

    2000-07-01

    To compare turbo spin-echo (TSE), breath-hold TSE and half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequences quantitatively and qualitatively in T2-weighted images of liver lesions. The authors evaluated prospectively 89 liver lesions in 73 patients using a 1.0-T magnetic resonance system to compare TSE, breath-hold TSE and HASTE sequences. The quantitative parameters were: lesion-to-liver contrast and lesion-to-liver contrast-to-noise ratio. The qualitative analysis was performed by two observers in consensus who examined four parameters: respiratory artifacts, lesion edge definition, intrahepatic vessel definition and image quality. Repeated measures analysis of variance was utilized to compare the quantitative variables and Friedman's nonparametric test for the qualitative parameters. In quantitative terms, the lesion-to-liver contrast was similar in TSE and breath-hold TSE sequences (2.45{+-}1.44 versus 2.60{+-}1.66), both of which were significantly better than the HASTE sequence (1.12{+-}0.72; p<0.001). The lesion-to-liver contrast-to-noise ratio was significantly higher in the TSE sequence (62.60{+-}46.40 versus 40.22{+-}25.35 versus 50.90{+-}32.10 for TSE, breath-hold TSE and HASTE sequences, respectively; p<0.001). In the qualitative comparisons, the HASTE sequence was significantly better than the TSE and breath-hold TSE sequences (p<0.001) in terms of artifacts and definition of lesion edge and intrahepatic vessels. Image quality was also significantly greater in the HASTE sequence (p<0.001). In quantitative terms, the TSE sequence is better than the breath-hold TSE and HASTE sequences, but there are no movement artifacts in the HASTE sequence, which is also significantly superior to TSE and breath-hold TSE sequences in qualitative terms and, thus, can be employed for T2-weighted images in liver studies. (Author) 17 refs.

  10. Carcinoma of the uterine cervix. High-resolution turbo spin-echo MR imaging with contrast-enhanced dynamic scanning and T2-weighting

    International Nuclear Information System (INIS)

    Abe, Y.; Yamashita, Y.; Namimoto, T.; Takahashi, M.; Katabuchi, H.; Tanaka, N.; Okamura, H.

    1998-01-01

    Purpose: To compare high-resolution contrast-enhanced (Gd-DTPA) dynamic MR imaging with T2-weighted turbo spin-echo (TSE) imaging in the evaluation of uterine cervical carcinoma. Material and Methods: Thirty-two patients with cervical carcinoma underwent MR imaging on a 1.5 T superconductive unit to have the extension of the disease assessed before treatment. A phased-array coil was used in all patients. In 25 patients, surgical confirmation of the diagnosis was obtained after imaging. Radiation therapy was selected for the remaining 7 patients with advanced carcinoma. Qualitative and quantitative image analyses were also performed. Results: The cervical carcinomas showed maximum contrast in the cervical stroma and myometrium in the early dynamic phase. The tumor/cervical-stroma contrast in the early dynamic phase obtained with the T1-weighted TSE technique (contrast-to-noise ratio 22.6) was significantly higher than that obtained in T2-weighted TSE imaging (contrast-to-noise ratio 4.3). In the evaluation of parametrial invasion, the accuracy of T2-weighted imaging was 71.8% and contrast-enhanced dynamic imaging 81.2%. Conclusion: High-resolution contrast-enhanced (Gd-DTPA) dynamic MR imaging in cervical cancer offers improved tumor/cervical-stroma contrast and provides useful information on parametrial invasion. (orig.)

  11. T2-Weighted Dixon Turbo Spin Echo for Accelerated Simultaneous Grading of Whole-Body Skeletal Muscle Fat Infiltration and Edema in Patients With Neuromuscular Diseases.

    Science.gov (United States)

    Schlaeger, Sarah; Klupp, Elisabeth; Weidlich, Dominik; Cervantes, Barbara; Foreman, Sarah C; Deschauer, Marcus; Schoser, Benedikt; Katemann, Christoph; Kooijman, Hendrik; Rummeny, Ernst J; Zimmer, Claus; Kirschke, Jan S; Karampinos, Dimitrios C

    2018-04-02

    The assessment of fatty infiltration and edema in the musculature of patients with neuromuscular diseases (NMDs) typically requires the separate performance of T1-weighted and fat-suppressed T2-weighted sequences. T2-weighted Dixon turbo spin echo (TSE) enables the generation of T2-weighted fat- and water-separated images, which can be used to assess both pathologies simultaneously. The present study examines the diagnostic performance of T2-weighted Dixon TSE compared with the standard sequences in 10 patients with NMDs and 10 healthy subjects. Whole-body magnetic resonance imaging was performed including T1-weighted Dixon fast field echo, T2-weighted short-tau inversion recovery, and T2-weighted Dixon TSE. Fatty infiltration and intramuscular edema were rated by 2 radiologists using visual semiquantitative rating scales. To assess intermethod and interrater agreement, weighted Cohen's κ coefficients were calculated. The ratings of fatty infiltration showed high intermethod and high interrater agreement (T1-weighted Dixon fast field echo vs T2-weighted Dixon TSE fat image). The evaluation of edematous changes showed high intermethod and good interrater agreement (T2-weighted short-tau inversion recovery vs T2-weighted Dixon TSE water image). T2-weighted Dixon TSE imaging is an alternative for accelerated simultaneous grading of whole-body skeletal muscle fat infiltration and edema in patients with NMDs.

  12. Contrast-enhanced turbo spin-echo(TSE) T1-weighted imaging: improved contrast of enhancing lesions

    International Nuclear Information System (INIS)

    Choi, Sung Wook; Lee, Ghi Jai; Shim, Jae Chan; Lee, Young Ju; Jeong, Se Hyung; Kim, Ho kyun

    1997-01-01

    The purpose of this study was to evaluate the effect of contrast improvement of enhancing brain lesions by inherent magnetization transfer effect in turbo spin-echo(TSE)T1-weighted MR imaging. Twenty-six enhancing lesions of 19 patients were included in this study. Using a 1.0T superconductive MR unit, contrast-enhanced SE T1-weighted images(TR=3D600 msec, TE=3D12 msec, NEX=3D2, acquistition time=3D4min 27sec) and contrast-enhanced TSE T1-weighted images(TR=3D600 msec, TE=3D12, acquistition time=3D1min 44sec) were obtained. Signal intensities at enhancing lesions and adjacent white matter were measured in the same regions of both images. Signal-to-noise ratio(SNR) of enhancing lesions and adjacent white matter, and con-trast-to-noise ratio(CNR) and lesion-to-background contrast (LBC) of enhancing lesions were calculated and statistically analysed using the paired t-test. On contrast-enhanced TSE T1-weighted images, SNR of enhancing lesions and adjacent white matter decreased by 18%(p<0.01) and 32%(p<0.01), respectively, compared to contrast-enhanced SE T1-weighted images. CNR and LBC of enhancing lesions increased by 16%(p<0.05) and 66%(p<0.01), respectively. Due to the proposed inherent magnetization transfer effects in TSE imaging, con-trast-enhanced T1-weighted TSE images demonstrated a statistically significant improvement in CNR and LBC, compared to conventional contrast-enhanced T1-weighted SE images, and scan time was much shorter

  13. Comparative study of image quality between axial T2-weighted BLADE and turbo spin-echo MRI of the upper abdomen on 3.0 T.

    Science.gov (United States)

    Zhang, Lin; Tian, ChunMei; Wang, PeiYuan; Chen, Liang; Mao, XiJin; Wang, ShanShan; Wang, Xu; Dong, JingMin; Wang, Bin

    2015-09-01

    To compare image quality of turbo spin-echo (TSE) with BLADE [which is also named periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER)] on magnetic resonance imaging (MRI) for upper abdomen. This study involved the retrospective evaluation of 103 patients (63 males, 40 females; age range 19-76 years; median age 53.8 years) who underwent 3.0 T MRI with both conventional TSE T2-weighted imaging (T2WI) and BLADE TSE T2WI. Two radiologists assessed respiratory motion, gastrointestinal peristalsis, and vascular pulsation artifacts, as well as the sharpness of the liver and pancreas edges. Scores for all magnetic resonance (MR) images were recorded. Wilcoxon's rank test was used to compare hierarchical data. Cohen's kappa coefficient was adopted to analyze interobserver consistency. Compared to TSE T2WI, BLADE TSE T2WI reduced all of the examined motion artifacts and increased the sharpness of the liver and pancreas edges (all P image quality.

  14. MR imaging findings of diffuse axonal injury: comparison of T2-weighted gradient images and T1- and T2-weighted spin-echo images

    Energy Technology Data Exchange (ETDEWEB)

    Park, Seo Young; Lee, Ghi Jai; Kim, Jeong Seok; Shim, Jae Chan; Kim, Ho Kyun [Inje Univ. College of Medicine, Seoul (Korea, Republic of)

    1998-10-01

    To compare T2-weighted images with spin-echo T1- and turbo spin-echo (TSE) T2-weighted images in patients with diffuse axonal injury(DAI). Using a 1.0T MR unit, SE T1-, TSE T2-, and and FLASH T2-weighted images were obtained from 69 patients with a history of head trauma. In 18MR images of 17 patients with imaging findings of DAI, T2-weighted images were retrospectively compared with SE T1- and TSE T2-weighted images. The interval between trauma and MR scan varied from 5 days to 24(mean, 11) months. Focusing on the number of lesions, and their location and signal intensity, as weel as associated findings, three images were simultaueously evaluated. In 18 MR images of 17 patients with MR imaging findings of DAI, 21 lesions were detected on T1-weighted images, 28 on TSE T2-weighted images, and 70 on T2-weighted images;the last of these revealed all lesions detected on the other two. Most lesions were hypointense on T1-weighted images(17/21), hyperintense on TSE T2-weighted (21/28), and hypointense on T2-weighted (63/70). Common locations for DAI were the frontal lobe (n=3D35) and corpus callosum (n=3D22). Associated brain injuries were cortical contusion (n=3D5), brainstem injury (n=3D3), deep gray matter injury (n=3D2), and subdural hematoma(n=3D1). In patients with DAI. T2-weighted images can detect more lesions and associated petechial hemorrhage than can TSE T2-weighted images. This modality is thus useful for the evaluation of patients with head trauma.=20.

  15. Acoustic noise reduction in T 1- and proton-density-weighted turbo spin-echo imaging.

    Science.gov (United States)

    Ott, Martin; Blaimer, Martin; Breuer, Felix; Grodzki, David; Heismann, Björn; Jakob, Peter

    2016-02-01

    To reduce acoustic noise levels in T 1-weighted and proton-density-weighted turbo spin-echo (TSE) sequences, which typically reach acoustic noise levels up to 100 dB(A) in clinical practice. Five acoustic noise reduction strategies were combined: (1) gradient ramps and shapes were changed from trapezoidal to triangular, (2) variable-encoding-time imaging was implemented to relax the phase-encoding gradient timing, (3) RF pulses were adapted to avoid the need for reversing the polarity of the slice-rewinding gradient, (4) readout bandwidth was increased to provide more time for gradient activity on other axes, (5) the number of slices per TR was reduced to limit the total gradient activity per unit time. We evaluated the influence of each measure on the acoustic noise level, and conducted in vivo measurements on a healthy volunteer. Sound recordings were taken for comparison. An overall acoustic noise reduction of up to 16.8 dB(A) was obtained by the proposed strategies (1-4) and the acquisition of half the number of slices per TR only. Image quality in terms of SNR and CNR was found to be preserved. The proposed measures in this study allowed a threefold reduction in the acoustic perception of T 1-weighted and proton-density-weighted TSE sequences compared to a standard TSE-acquisition. This could be achieved without visible degradation of image quality, showing the potential to improve patient comfort and scan acceptability.

  16. Three-dimensional isotropic T2-weighted cervical MRI at 3 T: Comparison with two-dimensional T2-weighted sequences

    International Nuclear Information System (INIS)

    Kwon, J.W.; Yoon, Y.C.; Choi, S.-H.

    2012-01-01

    Aim: To compare three-dimensional (3D) isotropic T2-weighted magnetic resonance imaging (MRI) sequences and reformation with two-dimensional (2D) T2-weighted sequences regarding image quality of the cervical spine at 3 T. Materials and methods: A phantom study was performed using a water-filled cylinder. The signal-to-noise and image homogeneity were evaluated. Fourteen (n = 14) volunteers were examined at 3 T using 3D isotropic T2-weighted sagittal and conventional 2D T2-weighted sagittal, axial, and oblique sagittal MRI. Multiplanar reformation (MPR) of the 3D T2-weighted sagittal dataset was performed simultaneously with image evaluation. In addition to artefact assessment, the visibility of anatomical structures in the 3D and 2D sequences was qualitatively assessed by two radiologists independently. Cohen’s kappa and Wilcoxon signed rank test were used for the statistical analysis. Result: The 3D isotropic T2-weighted sequence resulted in the highest signal-to-noise ratio (SNR) and lowest non-uniformity (NU) among the sequences in the phantom study. Quantitative evaluation revealed lower NU values of the cerebrospinal fluid (CSF) and muscles in 2D T2-weighted sagittal sequences compared to the 3D volume isotropic turbo spin-echo acquisition (VISTA) sequence. The other NU values revealed no statistically significant difference between the 2D turbo spin-echo (TSE) and 3D VISTA sequences (0.059 < p < 0.959). 3D VISTA images showed significantly fewer CSF flow artefacts (p < 0.001) and better delineated intradural nerve rootlets (p = 0.001) and neural foramina (p = 0.016) compared to 2D sequences. Conclusion: A 3D T2 weighted sequence is superior to conventional 2D sequences for the delineation of intradural nerve rootlets and neural foramina and is less affected by CSF flow artefacts.

  17. Application of fast spin-echo T[sub 2]-weighted imaging for examination of the neurocranium. Comparison with the conventional T[sub 2]-weighted spin-echo sequence. Die Anwendung der T[sub 2]-gewichteten Turbo-Spin-Echo-Sequenz zur Untersuchung des Neurokraniums. Vergleich mit der konventionellen T[sub 2]-gewichteten Spin-Echo-Sequenz

    Energy Technology Data Exchange (ETDEWEB)

    Siewert, C. (Strahlenklinik und Poliklinik, Universitaets-Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany)); Hosten, N. (Strahlenklinik und Poliklinik, Universitaets-Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany)); Felix, R. (Strahlenklinik und Poliklinik, Universitaets-Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany))

    1994-07-01

    T[sub 2]-weighted spin-echo imaging is the standard screening procedure in MR imaging of the neutrocranium. We evaluated fast spin-echo T[sub 2]-weighted imaging (TT[sub 2]) of the neurocranium in comparison to conventional spin-echo T[sub 2]-weighted imaging (T[sub 2]). Signal-to-noise and contrast-to-noise ratio of normal brain tissues (basal ganglia, grey and white matter, CSF fluid) and different pathologies were calculated. Signal-to-noise ratio and contrast-to-noise ratio were significantly higher than TT[sub 2] than in T[sub 2] (with the exception of grey-to-white matter contrast). Tissues with increased content of water protons (mobile protons) showed the highest contrast to surrounding tissues. The increased signal intensity of fat must be given due attention in fatty lesions. Because the contrast-to-noise ratio between white matter and basal ganglia is less in TT[sub 2], Parkinson patients have to be examined by conventional T[sub 2]. If these limitations are taken into account, fast spin-echo T[sub 2]-weighted imaging is well appropriate for MR imaging of the neurocranium, resulting in heavy T[sub 2]-weighting achieved in a short acquisition time. (orig.)

  18. Evaluation of the Subscapularis Tendon Tears on 3T Magnetic Resonance Arthrography: Comparison of Diagnostic Performance of T1-Weighted Spectral Presaturation with Inversion-Recovery and T2-Weighted Turbo Spin-Echo Sequences.

    Science.gov (United States)

    Lee, Hoseok; Ahn, Joong Mo; Kang, Yusuhn; Oh, Joo Han; Lee, Eugene; Lee, Joon Woo; Kang, Heung Sik

    2018-01-01

    To compare the T1-weighted spectral presaturation with inversion-recovery sequences (T1 SPIR) with T2-weighted turbo spin-echo sequences (T2 TSE) on 3T magnetic resonance arthrography (MRA) in the evaluation of the subscapularis (SSC) tendon tear with arthroscopic findings as the reference standard. This retrospective study included 120 consecutive patients who had undergone MRA within 3 months between April and December 2015. Two musculoskeletal radiologists blinded to the arthroscopic results evaluated T1 SPIR and T2 TSE images in separate sessions for the integrity of the SSC tendon, examining normal/articular-surface partial-thickness tear (PTTa)/full-thickness tear (FTT). Diagnostic performance of T1 SPIR and T2 TSE was calculated with arthroscopic results as the reference standard, and sensitivity, specificity, and accuracy were compared using the McNemar test. Interobserver agreement was measured with kappa (κ) statistics. There were 74 SSC tendon tears (36 PTTa and 38 FTT) confirmed by arthroscopy. Significant differences were found in the sensitivity and accuracy between T1 SPIR and T2 TSE using the McNemar test, with respective rates of 95.9-94.6% vs. 71.6-75.7% and 90.8-91.7% vs. 79.2-83.3% for detecting tear; 55.3% vs. 31.6-34.2% and 85.8% vs. 78.3-79.2%, respectively, for FTT; and 91.7-97.2% vs. 58.3-61.1% and 89% vs. 78-79.3%, respectively, for PTTa. Interobserver agreement for T1 SPIR was almost perfect for T1 SPIR (κ = 0.839) and substantial for T2 TSE (κ = 0.769). T1-weighted spectral presaturation with inversion-recovery sequences is more sensitive and accurate compared to T2 TSE in detecting SSC tendon tear on 3T MRA.

  19. Uterine cervical carcinoma: a comparison of two- and three-dimensional T2-weighted turbo spin-echo MR imaging at 3.0 T for image quality and local-regional staging

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Y.R. [The Catholic University of Korea, Department of Radiology, Seoul St. Mary' s Hospital, College of Medicine, 222, Banpo-daero, Seocho-gu, Seoul (Korea, Republic of); The Catholic University of Korea, Department of Radiology, Incheon St. Mary' s Hospital, College of Medicine, Bupyeong 6-dong, Bupyeong-gu, Incheon (Korea, Republic of); Rha, S.E.; Choi, B.G.; Oh, S.N.; Park, M.Y.; Byun, J.Y. [The Catholic University of Korea, Department of Radiology, Seoul St. Mary' s Hospital, College of Medicine, 222, Banpo-daero, Seocho-gu, Seoul (Korea, Republic of)

    2013-04-15

    To compare three-dimensional (3D) T2-weighted turbo spin-echo (TSE) with multiplanar two-dimensional (2D) T2-weighted TSE for the evaluation of invasive cervical carcinoma. Seventy-five patients with cervical carcinoma underwent MRI of the pelvis at 3.0 T, using both 5-mm-thick multiplanar 2D (total acquisition time = 12 min 25 s) and 1-mm-thick coronal 3D T2-weighted TSE sequences (7 min 20 s). Quantitative analysis of signal-to-noise ratio (SNR) and qualitative analysis of image quality were performed. Local-regional staging was performed in 45 patients who underwent radical hysterectomy. The estimated SNR of cervical carcinoma and the relative tumour contrast were significantly higher on 3D imaging (P < 0.0001). Tumour conspicuity was better with the 3D sequence, but the sharpness of tumour margin was better with the 2D sequence. No significant difference in overall image quality was noted between the two sequences (P = 0.38). There were no significant differences in terms of the diagnostic accuracy, sensitivity, and specificity of parametrial invasion, vaginal invasion, and lymph node metastases. Multiplanar reconstruction 3D T2-weighted imaging is largely equivalent to 2D T2-weighted imaging for overall image quality and staging accuracy of cervical carcinoma with a shorter MR data acquisition, but has limitations with regard to the sharpness of the tumour margin. circle 3D T2-weighted MR sequence is equivalent to 2D for cervical carcinoma staging. (orig.)

  20. Bone marrow lesions: evaluation with fat-suppression turbo spin echo MR imaging at 0.5T

    International Nuclear Information System (INIS)

    Chrysikopoulos, H.; Papazoglou, A.; Roussakis, A.; Andreou, J.

    1996-01-01

    The purpose of this study was the assessment of the diagnostic value of fat-suppression T2-weighted images for a variety of bone marrow lesions. We performed 40 studies of the axial or appendicular skeleton in 33 patients (age range 4-80 years) with neoplastic, inflammatory or traumatic lesions with a 0.5 T system (Gyroscan T5, Philips Medical Systems, Best, The Netherlands). Fat-suppression T2-weighted images [turbo spin echo (TSE) with spectral presaturation with inversion recovery (SPIR)] were obtained in addition to the routine T1-weighted SE and T2-weighted TSE sequences. Fat-suppression TSE T2-weighted images were better than standard TSE T2-weighted images in 25 studies. In 11 of them demonstration and characterization of the lesions (known from T1-weighted images) was possible only after fat suppression. In the other 14 patients demonstration of the full extent of the lesion especially to the nearby soft tissues was possible only after fat suppression. In 13 studies no advantage was conferred by SPIR, whereas in two instances T2-weighted images were better. Fat-suppression T2-weighted images are diagnostically useful in a variety of lesions of the musculoskeletal system, but their limitations should be known. (orig.)

  1. T2-weighted MR imaging of the liver: Qualitative and quantitative comparison of SPACE MR imaging with turbo spin-echo MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Dohan, Anthony, E-mail: anthony.dohan@lrb.aphp.fr [Department of Body and Interventional Imaging, Hôpital Lariboisière, AP-HP, 2 Rue Ambroise Paré, 75475 Paris Cedex 10 (France); Université Paris-Diderot, Sorbonne Paris Cité, 10 Rue de Verdun, 75010 Paris (France); UMR INSERM 965, Hôpital Lariboisière, 2 Rue Amboise Paré, 75010 Paris (France); Gavini, Jean-Philippe, E-mail: jpgavini@gmail.com [Department of Body and Interventional Imaging, Hôpital Lariboisière, AP-HP, 2 Rue Ambroise Paré, 75475 Paris Cedex 10 (France); Université Paris-Diderot, Sorbonne Paris Cité, 10 Rue de Verdun, 75010 Paris (France); Placé, Vinciane, E-mail: vinciane.place@gmail.com [Department of Body and Interventional Imaging, Hôpital Lariboisière, AP-HP, 2 Rue Ambroise Paré, 75475 Paris Cedex 10 (France); Sebbag, Delphine, E-mail: delphinesebbag@gmail.com [Department of Body and Interventional Imaging, Hôpital Lariboisière, AP-HP, 2 Rue Ambroise Paré, 75475 Paris Cedex 10 (France); Université Paris-Diderot, Sorbonne Paris Cité, 10 Rue de Verdun, 75010 Paris (France); Vignaud, Alexandre, E-mail: alexandre.vignaud@cea.fr [LRMN, Neurospin, CEA-SACLAY, Bâtiment 145, 91 191 Gif-sur-Yvette Cedex (France); and others

    2013-11-01

    Objective: To qualitatively and quantitatively compare T2-weighted MR imaging of the liver using volumetric spin-echo with sampling perfection with application-optimized contrast using different flip angle evolutions (SPACE) with conventional turbo spin-echo (TSE) sequence for fat-suppressed T2-weighted MR imaging of the liver. Materials and methods: Thirty-three patients with suspected focal liver lesions had SPACE MR imaging and conventional fat-suppressed TSE MR imaging. Images were analyzed quantitatively by measuring the lesion-to-liver contrast-to-noise ratio (CNR), and the signal-to-noise ratio (SNR) of main focal hepatic lesions, hepatic and splenic parenchyma and qualitatively by evaluating the presence of vascular, respiratory motion and cardiac artifacts. Wilcoxon signed rank test was used to search for differences between the two sequences. Results: SPACE MR imaging showed significantly greater CNR for focal liver lesions (median = 22.82) than TSE MR imaging (median = 14.15) (P < .001). No differences were found for SNR of hepatic parenchyma (P = .097), main focal hepatic lesions (P = .35), and splenic parenchyma (P = .25). SPACE sequence showed less artifacts than TSE sequence (vascular, P < .001; respiratory motion, P < .001; cardiac, P < .001) but needed a longer acquisition time (228.4 vs. 162.1 s; P < .001). Conclusion: SPACE MR imaging provides a significantly increased CNR for focal liver lesions and less artifacts by comparison with the conventional TSE sequence. These results should stimulate further clinical studies with a surgical standard of reference to compare the two techniques in terms of sensitivity for malignant lesions.

  2. Degenerative disc disease of the lumbar spine: a prospective comparison of fast T1-weighted fluid-attenuated inversion recovery and T1-weighted turbo spin echo MR imaging

    International Nuclear Information System (INIS)

    Erdem, L. Oktay; Erdem, C. Zuhal; Acikgoz, Bektas; Gundogdu, Sadi

    2005-01-01

    Objective: To compare fast T1-weighted fluid-attenuated inversion recovery (FLAIR) and T1-weighted turbo spin-echo (TSE) imaging of the degenerative disc disease of the lumbar spine. Materials and methods: Thirty-five consecutive patients (19 females, 16 males; mean age 41 years, range 31-67 years) with suspected degenerative disc disease of the lumbar spine were prospectively evaluated. Sagittal images of the lumbar spine were obtained using T1-weighted TSE and fast T1-weighted FLAIR sequences. Two radiologists compared these sequences both qualitatively and quantitatively. Results: On qualitative evaluation, CSF nulling, contrast at the disc-CSF interface, the disc-spinal cord (cauda equina) interface, and the spinal cord (cauda equina)-CSF interface of fast T1-weighted FLAIR images were significantly higher than those for T1-weighted TSE images (P < 0.001). On quantitative evaluation of the first 15 patients, signal-to-noise ratios of cerebrospinal fluid of fast T1-weighted FLAIR imaging were significantly lower than those for T1-weighted TSE images (P < 0.05). Contrast-to-noise ratios of spinal cord/CSF and normal bone marrow/disc for fast T1-weighted FLAIR images were significantly higher than those for T1-weighted TSE images (P < 0.05). Conclusion: Results in our study have shown that fast T1-weighted FLAIR imaging may be a valuable imaging modality in the armamentarium of lumbar spinal T1-weighted MR imaging, because the former technique has definite superior advantages such as CSF nulling, conspicuousness of the normal anatomic structures and changes in the lumbar spinal discogenic disease and image contrast and also almost equally acquisition times

  3. Degenerative disc disease of the lumbar spine: a prospective comparison of fast T1-weighted fluid-attenuated inversion recovery and T1-weighted turbo spin echo MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Erdem, L. Oktay [Department of Radiology, Zonguldak Karaelmas University, School of Medicine, 6700 Kozlu, Zonguldak (Turkey)]. E-mail: sunarerdem@yahoo.com; Erdem, C. Zuhal [Department of Radiology, Zonguldak Karaelmas University, School of Medicine, 6700 Kozlu, Zonguldak (Turkey); Acikgoz, Bektas [Department of Neurosurgery, Zonguldak Karaelmas University, School of Medicine, Zonguldak (Turkey); Gundogdu, Sadi [Department of Radiology, Zonguldak Karaelmas University, School of Medicine, 6700 Kozlu, Zonguldak (Turkey)

    2005-08-01

    Objective: To compare fast T1-weighted fluid-attenuated inversion recovery (FLAIR) and T1-weighted turbo spin-echo (TSE) imaging of the degenerative disc disease of the lumbar spine. Materials and methods: Thirty-five consecutive patients (19 females, 16 males; mean age 41 years, range 31-67 years) with suspected degenerative disc disease of the lumbar spine were prospectively evaluated. Sagittal images of the lumbar spine were obtained using T1-weighted TSE and fast T1-weighted FLAIR sequences. Two radiologists compared these sequences both qualitatively and quantitatively. Results: On qualitative evaluation, CSF nulling, contrast at the disc-CSF interface, the disc-spinal cord (cauda equina) interface, and the spinal cord (cauda equina)-CSF interface of fast T1-weighted FLAIR images were significantly higher than those for T1-weighted TSE images (P < 0.001). On quantitative evaluation of the first 15 patients, signal-to-noise ratios of cerebrospinal fluid of fast T1-weighted FLAIR imaging were significantly lower than those for T1-weighted TSE images (P < 0.05). Contrast-to-noise ratios of spinal cord/CSF and normal bone marrow/disc for fast T1-weighted FLAIR images were significantly higher than those for T1-weighted TSE images (P < 0.05). Conclusion: Results in our study have shown that fast T1-weighted FLAIR imaging may be a valuable imaging modality in the armamentarium of lumbar spinal T1-weighted MR imaging, because the former technique has definite superior advantages such as CSF nulling, conspicuousness of the normal anatomic structures and changes in the lumbar spinal discogenic disease and image contrast and also almost equally acquisition times.

  4. Evaluation of turbo spin echo sequences for MRI of focal liver lesions at 0.5 T

    International Nuclear Information System (INIS)

    Kreft, B.; Layer, G.; Steudel, A.; Spiller, L.; Heuck, A.; Mueller, A.; Gieseke, J.; Reiser, M.F.

    1994-01-01

    To determine whether turbo spin echo (TSE) sequences can replace conventional T2-weighted spin echo (SE) sequences in MRI of the liver, 40 patients with focal liver lesions were imaged at 0.5 T. A T2-weighted SE sequence (TR/TE 1800/90 ms, number of signals averaged [NEX] = 2, scan time 7:16 min), a TSE sequence (TR/TE 1800/90 ms, NEX = 4, number of echos per excitation = 13, echo spacing = 12.9 ms, scan time = 4:16 min) and a T1-weighted SE sequence (TR/TE 350/15 ms, NEX = 2, scan time = 4:21 min) were obtained and image quality, lesion detectability and lesion differentiation were evaluated qualitatively by subjective assessment using scores and quantitatively by lesion-liver contrast-to-noise (CNR) and tumour/liver signal intensity (SI) ratios. The image quality of the TSE sequence was substantially better compared with the T2-weighted SE sequence due to a reduction in motion artefacts and better delineation of anatomical details. Of a total of 158 visible lesions the T1-weighted SE, TSE and T2-weighted SE sequences showed 91 %, 81 % and 65 % of the lesions, respectively. Thus the TSE sequence depicted 24 % (P < 0.001) more lesions than the T2-weighted SE sequence. In all types of pathology the lesion-liver CNR of the TSE sequence was significantly (P < 0.001) higher compared to the CNR of the T2-weighted SE sequence ( +55-65 %), indicating superior lesion conspicuity. Lesion characterization was equally good on the two T2-weighted sequences with no difference in the tumour/liver SI ratio. Using a criterion of tumour/liver SI ratio equal to or higher than 2, haemangiomas larger than 1 cm in diameter could be differentiated from other lesions with a sensitivity and specificity of 95 % and 96 %, respectively. Our results indicate that the TSE sequence is suitable for replacing the conventional T2-weighted SE sequence in MRI of focal liver lesions. (orig.)

  5. Subjective and objective image qualities: a comparison of sagittal T2 weighted spin-echo and turbo-spin-eco sequences in magnetic resonance imaging of the spine by use of a subjective ranking system

    Energy Technology Data Exchange (ETDEWEB)

    Goerres, G. [Institut fuer diagnostische Radiologie, Departement Radiologie, Universitaetskliniken, Kantonsspital Basel (Switzerland); Mader, I. [Radiologische Gemeinschaftspraxis Dres. Siems, Grossmann, Bayreuth (Germany); Proske, M. [Klinikum Rosenheim (Germany). Inst. fuer Diagnostische Radiologie

    1998-12-31

    We evaluated the subjective image impression of two different magnetic resonance (MR) sequences by using a subjective ranking system. This ranking system was based on 20 criteria describing several tissue characteristics such as the signal intensity of normal anatomical structures and the changes of signal intensities and shape of lesions as well as artefacts. MR of the vertebral spine was performed in 48 female and 52 male patients (mean age 44.8 years) referred consecutively for investigation of a back problem. Ninety-six pathologies were found in 82 patients. Sagittal and axial T1 weighted spin-echo before and after administration of Gadolinium (Gd-DOTA), and sagittal T2 weighted spin-echo (T2wSE) and Turbo-spin-echo (TSE) sequences were performed by means of surface coils. Using the subjective ranking system the sagittal T2wSE and sagittal TSE were compared. Both sequences were suitable for identification of normal anatomy and pathologic changes and there was no trend for increased detection of disease by one imaging sequence over the other. We found that sagittal TSE sequences can replace sagittal T2wSE sequences in spinal MR and that artefacts at the cervical and lumbar spine are less frequent using TSE, thus confirming previous studies. In this study, our ranking system reveiled, that there are differences between the subjective judgement of image qualities and objective measurement of SNR. However, this approach may not be helpful to compare two different MR sequences as it is limited to the anatomical area investigated and is time consuming. The subjective image impression, i.e. the quality of images, may not always be represented by physical parameters such as a signal-to-noise ratio (SNR), radiologists should try to define influences of image quality also by subjective parameters. (orig.)

  6. Application of fast spin-echo T2-weighted imaging for examination of the neurocranium. Comparison with the conventional T2-weighted spin-echo sequence

    International Nuclear Information System (INIS)

    Siewert, C.; Hosten, N.; Felix, R.

    1994-01-01

    T 2 -weighted spin-echo imaging is the standard screening procedure in MR imaging of the neutrocranium. We evaluated fast spin-echo T 2 -weighted imaging (TT 2 ) of the neurocranium in comparison to conventional spin-echo T 2 -weighted imaging (T 2 ). Signal-to-noise and contrast-to-noise ratio of normal brain tissues (basal ganglia, grey and white matter, CSF fluid) and different pathologies were calculated. Signal-to-noise ratio and contrast-to-noise ratio were significantly higher than TT 2 than in T 2 (with the exception of grey-to-white matter contrast). Tissues with increased content of water protons (mobile protons) showed the highest contrast to surrounding tissues. The increased signal intensity of fat must be given due attention in fatty lesions. Because the contrast-to-noise ratio between white matter and basal ganglia is less in TT 2 , Parkinson patients have to be examined by conventional T 2 . If these limitations are taken into account, fast spin-echo T 2 -weighted imaging is well appropriate for MR imaging of the neurocranium, resulting in heavy T 2 -weighting achieved in a short acquisition time. (orig.) [de

  7. Whole-brain intracranial vessel wall imaging at 3 Tesla using cerebrospinal fluid-attenuated T1-weighted 3D turbo spin echo.

    Science.gov (United States)

    Fan, Zhaoyang; Yang, Qi; Deng, Zixin; Li, Yuxia; Bi, Xiaoming; Song, Shlee; Li, Debiao

    2017-03-01

    Although three-dimensional (3D) turbo spin echo (TSE) with variable flip angles has proven to be useful for intracranial vessel wall imaging, it is associated with inadequate suppression of cerebrospinal fluid (CSF) signals and limited spatial coverage at 3 Tesla (T). This work aimed to modify the sequence and develop a protocol to achieve whole-brain, CSF-attenuated T 1 -weighted vessel wall imaging. Nonselective excitation and a flip-down radiofrequency pulse module were incorporated into a commercial 3D TSE sequence. A protocol based on the sequence was designed to achieve T 1 -weighted vessel wall imaging with whole-brain spatial coverage, enhanced CSF-signal suppression, and isotropic 0.5-mm resolution. Human volunteer and pilot patient studies were performed to qualitatively and quantitatively demonstrate the advantages of the sequence. Compared with the original sequence, the modified sequence significantly improved the T 1 -weighted image contrast score (2.07 ± 0.19 versus 3.00 ± 0.00, P = 0.011), vessel wall-to-CSF contrast ratio (0.14 ± 0.16 versus 0.52 ± 0.30, P = 0.007) and contrast-to-noise ratio (1.69 ± 2.18 versus 4.26 ± 2.30, P = 0.022). Significant improvement in vessel wall outer boundary sharpness was observed in several major arterial segments. The new 3D TSE sequence allows for high-quality T 1 -weighted intracranial vessel wall imaging at 3 T. It may potentially aid in depicting small arteries and revealing T 1 -mediated high-signal wall abnormalities. Magn Reson Med 77:1142-1150, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  8. Detection of brain metastasis. Comparison of Turbo-FLAIR imaging, T2-weighted imaging and double-dose gadolinium-enhanced MR imaging

    International Nuclear Information System (INIS)

    Okubo, Toshiyuki; Hayashi, Naoto; Shirouzu, Ichiro; Abe, Osamu; Ohtomo, Kuni; Sasaki, Yasuhito; Aoki, Shigeki; Wada, Akihiko

    1998-01-01

    The purpose of this study was to compare Turbo-FLAIR imaging, T 2 -weighted imaging, and double-dose gadolinium-enhanced MR imaging in the detection of brain metastasis. Using the three sequences, 20 consecutive patients with brain metastases were prospectively studied with a 1.5-Tesla system. Three independent, blinded readers assessed the images for the presence, size, number, and location of metastatic lesions. In the detection of large lesions (>0.5 cm), Turbo-FLAIR imaging (38/48, 79%) was not significantly different from gadolinium-enhanced imaging (42/48, 88%) (p=0.273). T 2 -weighted imaging (31/48, 65%), however, was inferior to gadolinium-enhanced imaging (p<0.05). There was no difference between Turbo-FLAIR imaging and gadolinium-enhanced imaging in the accuracy of detecting solitary brain metastasis (4/4, 100%). In conclusion, Turbo-FLAIR imaging is a useful, noninvasive screening modality for brain metastasis. Its use may lead to cost savings in the diagnosis of brain metastases and may impact positively the cost-effectiveness of treatment. (author)

  9. Can a single-shot black-blood T2-weighted spin-echo echo-planar imaging sequence with sensitivity encoding replace the respiratory-triggered turbo spin-echo sequence for the liver? An optimization and feasibility study.

    Science.gov (United States)

    Hussain, Shahid M; De Becker, Jan; Hop, Wim C J; Dwarkasing, Soendersing; Wielopolski, Piotr A

    2005-03-01

    To optimize and assess the feasibility of a single-shot black-blood T2-weighted spin-echo echo-planar imaging (SSBB-EPI) sequence for MRI of the liver using sensitivity encoding (SENSE), and compare the results with those obtained with a T2-weighted turbo spin-echo (TSE) sequence. Six volunteers and 16 patients were scanned at 1.5T (Philips Intera). In the volunteer study, we optimized the SSBB-EPI sequence by interactively changing the parameters (i.e., the resolution, echo time (TE), diffusion weighting with low b-values, and polarity of the phase-encoding gradient) with regard to distortion, suppression of the blood signal, and sensitivity to motion. The influence of each change was assessed. The optimized SSBB-EPI sequence was applied in patients (N = 16). A number of items, including the overall image quality (on a scale of 1-5), were used for graded evaluation. In addition, the signal-to-noise ratio (SNR) of the liver was calculated. Statistical analysis was carried out with the use of Wilcoxon's signed rank test for comparison of the SSBB-EPI and TSE sequences, with P = 0.05 considered the limit for significance. The SSBB-EPI sequence was improved by the following steps: 1) less frequency points than phase-encoding steps, 2) a b-factor of 20, and 3) a reversed polarity of the phase-encoding gradient. In patients, the mean overall image quality score for the optimized SSBB-EPI (3.5 (range: 1-4)) and TSE (3.6 (range: 3-4)), and the SNR of the liver on SSBB-EPI (mean +/- SD = 7.6 +/- 4.0) and TSE (8.9 +/- 4.6) were not significantly different (P > .05). Optimized SSBB-EPI with SENSE proved to be feasible in patients, and the overall image quality and SNR of the liver were comparable to those achieved with the standard respiratory-triggered T2-weighted TSE sequence. (c) 2005 Wiley-Liss, Inc.

  10. Improved visualization of collateral ligaments of the ankle: multiplanar reconstructions based on standard 2D turbo spin-echo MR images

    International Nuclear Information System (INIS)

    Duc, Sylvain R.; Mengiardi, Bernard; Pfirrmann, Christian W.A.; Hodler, Juerg; Zanetti, Marco

    2007-01-01

    The purpose of the study was to evaluate the visualization of the collateral ankle ligaments on multiplanar reconstructions (MPR) based on standard 2D turbo spin-echo images. Coronal and axial T2-weighted turbo spin-echo and MPR angled parallel to the course of the ligaments of 15 asymptomatic and 15 symptomatic ankles were separately analyzed by two musculoskeletal radiologists. Image quality was assessed in the asymptomatic ankles qualitatively. In the symptomatic ankles interobserver agreement and reader confidence was determined for each ligament. On MPR the tibionavicular and calcaneofibular ligaments were more commonly demonstrated on a single image than on standard MR images (reader 1: 13 versus 0, P=0.002; reader 2: 14 versus 1, P=0.001 and reader 1: 13 versus 2, P=0.001; reader 2: 14 versus 0, P<0.001). The tibionavicular ligament was considered to be better delineated on MPR by reader 1 (12 versus 3, P=0.031). In the symptomatic ankles, reader confidence was greater with MPR for all ligaments except for the tibiocalcanear ligament (both readers) and the anterior and posterior talofibular ligaments (for reader 2). Interobserver agreement was increased with MPR for the tibionavicular ligament. Multiplanar reconstructions of 2D turbo spin-echo images improve the visualization of the tibionavicular and calcaneofibular ligaments and strengthen diagnostic confidence for these ligaments. (orig.)

  11. Diagnosis of nerve root compromise of the lumbar spine: Evaluation of the performance of three-dimensional isotropic T2-weighted turbo spin-echo SPACE sequence at 3T

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Jin Kyeong; Jee, Won Hee; Jung, Joon Yong; Jang, Jin Hee; Kim, Jin Sung; Kim, Young Hoon; Ha, Kee Yong [Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2017-01-15

    To explore the performance of three-dimensional (3D) isotropic T2-weighted turbo spin-echo (TSE) sampling perfection with application optimized contrasts using different flip angle evolution (SPACE) sequence on a 3T system, for the evaluation of nerve root compromise by disc herniation or stenosis from central to extraforaminal location of the lumbar spine, when used alone or in combination with conventional two-dimensional (2D) TSE sequence. Thirty-seven patients who had undergone 3T spine MRI including 2D and 3D sequences, and had subsequent spine surgery for nerve root compromise at a total of 39 nerve levels, were analyzed. A total of 78 nerve roots (48 symptomatic and 30 asymptomatic sites) were graded (0 to 3) using different MRI sets of 2D, 3D (axial plus sagittal), 3D (all planes), and combination of 2D and 3D sequences, with respect to the nerve root compromise caused by posterior disc herniations, lateral recess stenoses, neural foraminal stenoses, or extraforaminal disc herniations; grading was done independently by two readers. Diagnostic performance was compared between different imaging sets using the receiver operating characteristics (ROC) curve analysis. There were no statistically significant differences (p = 0.203 to > 0.999) in the ROC curve area between the imaging sets for both readers 1 and 2, except for combined 2D and 3D (0.843) vs. 2D (0.802) for reader 1 (p = 0.035), and combined 2D and 3D (0.820) vs. 3D including all planes (0.765) for reader 2 (p = 0.049). The performance of 3D isotropic T2-weighted TSE sequence of the lumbar spine, whether axial plus sagittal images, or all planes of images, was not significantly different from that of 2D TSE sequences, for the evaluation of nerve root compromise of the lumbar spine. Combining 2D and 3D might possibly improve the diagnostic accuracy compared with either one.

  12. Comparison of Diffusion-Weighted Imaging in the Human Brain Using Readout-Segmented EPI and PROPELLER Turbo Spin Echo With Single-Shot EPI at 7 T MRI.

    Science.gov (United States)

    Kida, Ikuhiro; Ueguchi, Takashi; Matsuoka, Yuichiro; Zhou, Kun; Stemmer, Alto; Porter, David

    2016-07-01

    The purpose of the present study was to compare periodically rotated overlapping parallel lines with enhanced reconstruction-type turbo spin echo diffusion-weighted imaging (pTSE-DWI) and readout-segmented echo planar imaging (rsEPI-DWI) with single-shot echo planar imaging (ssEPI-DWI) in a 7 T human MR system. We evaluated the signal-to-noise ratio (SNR), image distortion, and apparent diffusion coefficient values in the human brain. Six healthy volunteers were included in this study. The study protocol was approved by our institutional review board. All measurements were performed at 7 T using pTSE-DWI, rsEPI-DWI, and ssEPI-DWI sequences. The spatial resolution was 1.2 × 1.2 mm in-plane with a 3-mm slice thickness. Signal-to-noise ratio was measured using 2 scans. The ssEPI-DWI sequence showed significant image blurring, whereas pTSE-DWI and rsEPI-DWI sequences demonstrated high image quality with low geometrical distortion compared with reference T2-weighted, turbo spin echo images. Signal loss in ventral regions near the air-filled paranasal sinus/nasal cavity was found in ssEPI-DWI and rsEPI-DWI but not pTSE-DWI. The apparent diffusion coefficient values for ssEPI-DWI were 824 ± 17 × 10 and 749 ± 25 × 10 mm/s in the gray matter and white matter, respectively; the values obtained for pTSE-DWI were 798 ± 21 × 10 and 865 ± 40 × 10 mm/s; and the values obtained for rsEPI-DWI were 730 ± 12 × 10 and 722 ± 25 × 10 mm/s. The pTSE-DWI images showed no additional distortion comparison to the T2-weighted images, but had a lower SNR than ssEPI-DWI and rsEPI-DWI. The rsEPI-DWI sequence provided high-quality images with minor distortion and a similar SNR to ssEPI-DWI. Our results suggest that the benefits of the rsEPI-DWI and pTSE-DWI sequences, in terms of SNR, image quality, and image distortion, appear to outweigh those of ssEPI-DWI. Thus, pTSE-DWI and rsEPI-DWI at 7 T have great potential use for clinical diagnoses. However, it is noteworthy that both

  13. Analysis of artefacts and detail resolution of lung MRI with breath-hold T1-weighted gradient-echo and T2-weighted fast spin-echo sequences with respiratory triggering

    International Nuclear Information System (INIS)

    Biederer, J.; Reuter, M.; Both, M.; Grimm, J.; Heller, M.; Muhle, C.; Graessner, J.

    2002-01-01

    The aim of this study was to evaluate feasibility and limitations of two MR sequences for imaging of the lung using a semi-quantitative rating scale. Ten healthy volunteers were assessed with a breath-hold T1-weighted gradient-recalled-echo (TR/TE=129/2.2 ms, matrix 173 x 256) and a T2-weighted turbo spin-echo (TSE) sequence with respiratory triggering (TR/TE=3000-5000/120 ms, matrix 270 x 512) in axial 6-mm slices. The T1-weighted GRE protocol included a pre-saturation pulse over the mediastinal structures. Artefacts and resolution of vessel/airway structures in each lung segment were evaluated by two observers (10 volunteers, 180 segments). Cardiac and vessel pulsation artefacts predominated on T1-weighted GRE, respiration artefacts on T2-weighted TSE (lingula and middle lobe). Pre-saturation of the mediastinum reduced pulsation artefacts on T1-weighted GRE. T1-weighted GRE images were improved by bright flow signal of vessels, whereas image quality of T2-weighted TSE was reduced by black-blood effects in central parts of the lung. Delineation of lung periphery and the mediastinum was superior with T2-weighted TSE. Segmental/sub-segmental vessels (up to fourth/fifth order) and bronchi (up to third order) were identified. All 180 lung segments were imaged in diagnostic quality with at least one of the two sequences (T1-weighted GRE not diagnostic in 9 of 180, T2-weighted TSE in 4 of 180). Both sequences were found to be complementary: superior identification of gross lung anatomy with T1-weighted GRE and higher detail resolution in the periphery and the mediastinum with T2-weighted TSE. (orig.)

  14. Semicircular canal dehiscence: comparison of T2-weighted turbo spin-echo MRI and CT

    Energy Technology Data Exchange (ETDEWEB)

    Krombach, G.A.; Schmitz-Rode, T.; Haage, P.; Guenther, R.W. [Department of Diagnostic Radiology, University of Technology, Pauwelstrasse 30, 52057, Aachen (Germany); DiMartino, E. [Department of Otorhinolaryngology, University of Technology, Pauwelstrasse 30, 52057, Aachen (Germany); Prescher, A. [Department of Anatomy, University of Technology, Pauwelstrasse 30, 52057, Aachen (Germany); Kinzel, S. [Department of Experimental Veterinary Medicine, University of Technology, Pauwelstrasse 30, 52057, Aachen (Germany)

    2004-04-01

    We assessed the value of MRI for delineation of dehiscence of the superior or posterior semicircular canal, as compared with CT, the current standard study for this entity. We reviewed heavily T2-weighted fast spin-echo images and high-resolution CT of the temporal bones of 185 patients independently semicircular canal dehiscence and its extent. In 30 patients (19 men, 11 women) we identified dehiscence of the bone over the superior and/or posterior semicircular canal on MRI. In 27 of these cases CT also showed circumscribed bone defects. In one patient dehiscence of the superior semicircular canal was initially overlooked on MRI, but seen on CT. MRI imaging thus had a sensitivity of 96% and specificity of 98%. Knowledge of the appearances of this entity on MRI may contribute to early diagnosis in patients with vertigo due to semicircular canal dehiscence. (orig.)

  15. Semicircular canal dehiscence: comparison of T2-weighted turbo spin-echo MRI and CT

    International Nuclear Information System (INIS)

    Krombach, G.A.; Schmitz-Rode, T.; Haage, P.; Guenther, R.W.; DiMartino, E.; Prescher, A.; Kinzel, S.

    2004-01-01

    We assessed the value of MRI for delineation of dehiscence of the superior or posterior semicircular canal, as compared with CT, the current standard study for this entity. We reviewed heavily T2-weighted fast spin-echo images and high-resolution CT of the temporal bones of 185 patients independently semicircular canal dehiscence and its extent. In 30 patients (19 men, 11 women) we identified dehiscence of the bone over the superior and/or posterior semicircular canal on MRI. In 27 of these cases CT also showed circumscribed bone defects. In one patient dehiscence of the superior semicircular canal was initially overlooked on MRI, but seen on CT. MRI imaging thus had a sensitivity of 96% and specificity of 98%. Knowledge of the appearances of this entity on MRI may contribute to early diagnosis in patients with vertigo due to semicircular canal dehiscence. (orig.)

  16. Usefulness of turbo spin-echo MR imaging in meniscal tears of the knee

    International Nuclear Information System (INIS)

    Jeong, Gun Young; Choi, Chang Lak; Chung, Jin Young; Han, Tae Il; Jang, Hong Im; Kim, Ji Min; Han, Hyun Young; Song, Mun Kab; Yang, Chang Kyu

    1998-01-01

    To evaluate the usefulness and diagnostic accuracy of turbo spin-echo(TSE) proton-density and T2-weighted images of meniscal tears of the knee. We retrospectively evaluated the sensitivity, specificity, and accuracy of TSE proton density and T2-weighted images of meniscal tears confirmed arthroscopically or surgically in 47 patients(98 menisci). The routine TSE parameters used in all patients were the dual echo sequence with sagittal proton density and T2-weighed images(4000/16, 90/5/2 [TR/effectiveTE/ETL/NEX]), and fat-suppressed coronal proton density and T2-weighted images. The chi-square test was used for statistical analysis. The sensitivity, specificity, and accuracy of TSE proton density images for the detection of meniscal tears were 93.9%, 93.8%, and 93.9%, respectively, in the medial meniscus, and 92.9%, 91.4%, and 91.8% in the lateral. On T2-weighted images the corresponding figures were 87.9%, 8%, and 89.8%, respectively, in the medial meniscus, and 64.3%, 91.4%, and 83.7% in the lateral. With regard to sensitivity and accuracy, TSE proton density images of meniscal tears were superior to TSE T2-weighted images.=20

  17. Importance of T2*-weighted gradient-echo MRI for diagnosis of cortical vein thrombosis

    Energy Technology Data Exchange (ETDEWEB)

    Fellner, Franz A. [Institut fuer Radiologie, Landes-Nervenklinik Wagner Jauregg, Linz (Austria) and Zentrales Radiologie Institut, Allgemeines Krankenhaus der Stadt Linz, Krankenhausstr. 9, 4020 Linz (Austria)]. E-mail: franz.fellner@akh.linz.at; Fellner, Claudia [Institut fuer Radiologie, Landes-Nervenklinik Wagner Jauregg, Linz (Austria); Aichner, Franz T. [Abteilung fuer Neurologie, Landes-Nervenklinik Wagner-Jauregg, Linz (Austria); Moelzer, Guenther [Institut fuer Radiologie, Landes-Nervenklinik Wagner Jauregg, Linz (Austria)

    2005-11-01

    We examined six patients with isolated venous thrombosis (n = 2), or venous thrombosis combined with sinus thrombosis (n = 4) (CVT). The clinical symptoms were non-specific (acute cephalea, paresis, epileptic seizure, progressive speech disorder). All examinations were performed on a 1.5 T system (Magnetom Symphony, Siemens, Erlangen, Germany), maximum gradient field strength 30 mT/m, minimal gradient rise time 450 {mu}s, according to the following protocol: Transverse T2-weighted turbo spin-echo (TSE), fluid attenuated inversion recovery (FLAIR), T1-weighted spin-echo (SE), before and after administration of contrast medium, T2*-weighted conventional gradient-echo (GRE), T2*-weighted spin-echo echo planar imaging (SE EPI), both without and with diffusion weighting as well as two-dimensional (2D) venous time-of-flight (TOF) MRA. The venous thromboses were best detectable in the T2*-weighted conventional GRE sequence in all patients. In two patients, the CVT was discernible only in this sequence. The sinus thrombosis was well discernible only in the T2*-weighted GRE sequence in only one case; in the remaining cases it was detectable only with difficulty. For these cases, other sequences such as SE, diffusion-weighted, or 2D-TOF-MRA sequence were superior. The T2*-weighted conventional GRE sequence was superior to the T2*-weighted SE EPI sequence in all patients. To sum up, it can be concluded, that T2*-weighted conventional GRE sequences are possibly the best method of detection of acute cortical vein thromboses. Therefore, it seems to be of benefit to integrate a T2*-weighted conventional GRE sequence into the MR-protocol for the diagnosis of isolated cortical vein thrombosis.

  18. Importance of T2*-weighted gradient-echo MRI for diagnosis of cortical vein thrombosis

    International Nuclear Information System (INIS)

    Fellner, Franz A.; Fellner, Claudia; Aichner, Franz T.; Moelzer, Guenther

    2005-01-01

    We examined six patients with isolated venous thrombosis (n = 2), or venous thrombosis combined with sinus thrombosis (n = 4) (CVT). The clinical symptoms were non-specific (acute cephalea, paresis, epileptic seizure, progressive speech disorder). All examinations were performed on a 1.5 T system (Magnetom Symphony, Siemens, Erlangen, Germany), maximum gradient field strength 30 mT/m, minimal gradient rise time 450 μs, according to the following protocol: Transverse T2-weighted turbo spin-echo (TSE), fluid attenuated inversion recovery (FLAIR), T1-weighted spin-echo (SE), before and after administration of contrast medium, T2*-weighted conventional gradient-echo (GRE), T2*-weighted spin-echo echo planar imaging (SE EPI), both without and with diffusion weighting as well as two-dimensional (2D) venous time-of-flight (TOF) MRA. The venous thromboses were best detectable in the T2*-weighted conventional GRE sequence in all patients. In two patients, the CVT was discernible only in this sequence. The sinus thrombosis was well discernible only in the T2*-weighted GRE sequence in only one case; in the remaining cases it was detectable only with difficulty. For these cases, other sequences such as SE, diffusion-weighted, or 2D-TOF-MRA sequence were superior. The T2*-weighted conventional GRE sequence was superior to the T2*-weighted SE EPI sequence in all patients. To sum up, it can be concluded, that T2*-weighted conventional GRE sequences are possibly the best method of detection of acute cortical vein thromboses. Therefore, it seems to be of benefit to integrate a T2*-weighted conventional GRE sequence into the MR-protocol for the diagnosis of isolated cortical vein thrombosis

  19. Contrast-enhanced MR imaging of metastatic brain tumor at 3 Tesla. Utility of T1-weighted SPACE compared with 2D spin echo and 3D gradient echo sequence

    International Nuclear Information System (INIS)

    Komada, Tomohiro; Naganawa, Shinji; Ogawa, Hiroshi

    2008-01-01

    We evaluated the newly developed whole-brain, isotropic, 3-dimensional turbo spin-echo imaging with variable flip angle echo train (SPACE) for contrast-enhanced T 1 -weighted imaging in detecting brain metastases at 3 tesla (T). Twenty-two patients with suspected brain metastases underwent postcontrast study with SPACE, magnetization-prepared rapid gradient-echo (MP-RAGE), and 2-dimensional T 1 -weighted spin echo (2D-SE) imaging at 3 T. We quantitatively compared SPACE, MP-RAGE, and 2D-SE images by using signal-to-noise ratios (SNRs) for gray matter (GM) and white matter (WM) and contrast-to-noise ratios (CNRs) for GM-to-WM, lesion-to-GM, and lesion-to-WM. Two blinded radiologists evaluated the detection of brain metastases by segment-by-segment analysis and continuously-distributed test. The CNR between GM and WM was significantly higher on MP-RAGE images than on SPACE images (P 1 -weighted imaging. (author)

  20. Improved fat-suppression homogeneity with mDIXON turbo spin echo (TSE) in pediatric spine imaging at 3.0 T.

    Science.gov (United States)

    Pokorney, Amber L; Chia, Jonathan M; Pfeifer, Cory M; Miller, Jeffrey H; Hu, Houchun H

    2017-11-01

    Background Robust fat suppression remains essential in clinical MRI to improve tissue signal contrast, minimize fat-related artifacts, and enhance image quality. Purpose To compare fat suppression between mDIXON turbo spin echo (TSE) and conventional frequency-selective and inversion-recovery methods in pediatric spine MRI. Material and Methods Images from T1-weighted (T1W) and T2-weighted (T2W) TSE sequences coupled with conventional methods and the mDIXON technique were compared in 36 patients (5.8 ± 5.4 years) at 3.0 T. Images from 42 pairs of T1W (n = 16) and T2W (n = 26) scans were acquired. Two radiologists reviewed the data and rated images using a three-point scale in two categories, including the uniformity of fat suppression and overall diagnostic image quality. The Wilcoxon rank-sum test was used to compare the scores. Results The Cohen's kappa coefficient for inter-rater agreement was 0.69 (95% confidence interval [CI], 0.56-0.83). Images from mDIXON TSE were considered superior in fat suppression ( P 3.0 T and should be considered as a permanent replacement of traditional methods, in particular frequency-selective techniques.

  1. MR imaging of the knee: Improvement of signal and contrast efficiency of T1-weighted turbo spin echo sequences by applying a driven equilibrium (DRIVE) pulse

    Energy Technology Data Exchange (ETDEWEB)

    Radlbauer, Rudolf, E-mail: rudolf.radlbauer@stpoelten.lknoe.a [MR Physics Group, Department of Radiology, Landesklinikum St. Poelten, Propst Fuehrer Strasse 4, 3100 St. Poelten (Austria); Lomoschitz, Friedrich, E-mail: friedrich.lomoschitz@stpoelten.lknoe.a [MR Physics Group, Department of Radiology, Landesklinikum St. Poelten, Propst Fuehrer Strasse 4, 3100 St. Poelten (Austria); Salomonowitz, Erich, E-mail: erich.salomonowitz@stpoelten.lknoe.a [MR Physics Group, Department of Radiology, Landesklinikum St. Poelten, Propst Fuehrer Strasse 4, 3100 St. Poelten (Austria); Eberhardt, Knut E., E-mail: info@mrt-kompetenzzentrum.d [MRT Competence Center Schloss Werneck, Balthasar-Neumann-Platz 2, 97440 Werneck (Germany); Stadlbauer, Andreas, E-mail: andi@nmr.a [MR Physics Group, Department of Radiology, Landesklinikum St. Poelten, Propst Fuehrer Strasse 4, 3100 St. Poelten (Austria); Department of Neurosurgery, University of Erlangen-Nuremberg, Schwabachanlage 6, 91054 Erlangen (Germany)

    2010-08-15

    The purpose of this study was to assess the effect of a driven equilibrium (DRIVE) pulse incorporated in a standard T1-weighted turbo spin echo (TSE) sequence as used in our routine MRI protocol for examination of pathologies of the knee. Sixteen consecutive patients with knee disorders were examined using the routine MRI protocol, including T1-weighted TSE-sequences with and without a DRIVE pulse. Signal-to-noise ratios (SNRs) and contrast-to-noise ratio (CNR) of anatomical structures and pathologies were calculated and compared for both sequences. The differences in diagnostic value of the T1-weighted images with and without DRIVE pulse were assessed. SNR was significantly higher on images acquired with DRIVE pulse for fluid, effusion, cartilage and bone. Differences in the SNR of meniscus and muscle between the two sequences were not statistically significant. CNR was significantly increased between muscle and effusion, fluid and cartilage, fluid and meniscus, cartilage and meniscus, bone and cartilage on images acquired using the DRIVE pulse. Diagnostic value of the T1-weighted images was found to be improved for delineation of anatomic structures and for diagnosing a variety of pathologies when a DRIVE pulse is incorporated in the sequence. Incorporation of a DRIVE pulse into a standard T1-weighted TSE-sequence leads to significant increase of SNR and CNR of both, anatomical structures and pathologies, and consequently to an increase in diagnostic value within the same acquisition time.

  2. MR imaging of the knee: Improvement of signal and contrast efficiency of T1-weighted turbo spin echo sequences by applying a driven equilibrium (DRIVE) pulse

    International Nuclear Information System (INIS)

    Radlbauer, Rudolf; Lomoschitz, Friedrich; Salomonowitz, Erich; Eberhardt, Knut E.; Stadlbauer, Andreas

    2010-01-01

    The purpose of this study was to assess the effect of a driven equilibrium (DRIVE) pulse incorporated in a standard T1-weighted turbo spin echo (TSE) sequence as used in our routine MRI protocol for examination of pathologies of the knee. Sixteen consecutive patients with knee disorders were examined using the routine MRI protocol, including T1-weighted TSE-sequences with and without a DRIVE pulse. Signal-to-noise ratios (SNRs) and contrast-to-noise ratio (CNR) of anatomical structures and pathologies were calculated and compared for both sequences. The differences in diagnostic value of the T1-weighted images with and without DRIVE pulse were assessed. SNR was significantly higher on images acquired with DRIVE pulse for fluid, effusion, cartilage and bone. Differences in the SNR of meniscus and muscle between the two sequences were not statistically significant. CNR was significantly increased between muscle and effusion, fluid and cartilage, fluid and meniscus, cartilage and meniscus, bone and cartilage on images acquired using the DRIVE pulse. Diagnostic value of the T1-weighted images was found to be improved for delineation of anatomic structures and for diagnosing a variety of pathologies when a DRIVE pulse is incorporated in the sequence. Incorporation of a DRIVE pulse into a standard T1-weighted TSE-sequence leads to significant increase of SNR and CNR of both, anatomical structures and pathologies, and consequently to an increase in diagnostic value within the same acquisition time.

  3. A prospective comparison study of fast T1 weighted fluid attenuation inversion recovery and T1 weighted turbo spin echo sequence at 3 T in degenerative disease of the cervical spine.

    Science.gov (United States)

    Ganesan, K; Bydder, G M

    2014-09-01

    This study compared T1 fluid attenuation inversion recovery (FLAIR) and T1 turbo spin echo (TSE) sequences for evaluation of cervical spine degenerative disease at 3 T. 72 patients (44 males and 28 females; mean age of 39 years; age range, 27-75 years) with suspected cervical spine degenerative disease were prospectively evaluated. Sagittal images of the spine were obtained using T1 FLAIR and T1 TSE sequences. Two experienced neuroradiologists compared the sequences qualitatively and quantitatively. On qualitative evaluation, cerebrospinal fluid (CSF) nulling and contrast at cord-CSF, disc-CSF and disc-cord interfaces were significantly higher on fast T1 FLAIR images than on T1 TSE images (p degenerative disease, owing to higher cord-CSF, disc-cord and disc-CSF contrast. However, intrinsic cord contrast is low on T1 FLAIR images. T1 FLAIR is more promising and sensitive than T1 TSE for evaluation of degenerative spondyloarthropathy and may provide a foundation for development of MR protocols for early detection of degenerative and neoplastic diseases.

  4. Qualitative and quantitative assessment of wrist MRI at 3.0T - Comparison between isotropic 3D turbo spin echo and isotropic 3D fast field echo and 2D turbo spin echo

    International Nuclear Information System (INIS)

    Jung, Jee Young; Yoon, Young Cheol; Jung, Jin Young; Choe, Bong-Keun

    2013-01-01

    Background: Isotropic three-dimensional (3D) magnetic resonance imaging (MRI) has been applied to various joints. However, comparison for image quality between isotropic 3D MRI and two-dimensional (2D) turbo spin echo (TSE) sequence of the wrist at a 3T MR system has not been investigated. Purpose: To compare the image quality of isotropic 3D MRI including TSE intermediate-weighted (VISTA) sequence and fast field echo (FFE) sequence with 2D TSE intermediate-weighted sequence of the wrist joint at 3.0 T. Material and Methods: MRI was performed in 10 wrists of 10 healthy volunteers with isotropic 3D sequences (VISTA and FFE) and 2D TSE intermediate-weighted sequences at 3.0 T. The signal-to-noise ratio (SNR) was obtained by imaging phantom and noise-only image. Contrast ratios (CRs) were calculated between fluid and cartilage, triangular fibrocartilage complex (TFCC), and the scapholunate ligament. Two radiologists independently assessed the visibility of TFCC, carpal ligaments, cartilage, tendons and nerves with a four-point grading scale. Statistical analysis to compare CRs (one way ANOVA with a Tukey test) and grades of visibility (Kruskal-Wallis test) between three sequences and those for inter-observer agreement (kappa analysis) were performed. Results: The SNR of 2D TSE (46.26) was higher than those of VISTA (23.34) and 3D FFE (19.41). CRs were superior in 2D TSE than VISTA (P = 0.02) for fluid-cartilage and in 2D TSE than 3D FFE (P < 0.01) for fluid-TFCC. The visibility was best in 2D TSE (P < 0.01) for TFCC and in VISTA (P = 0.01) for scapholunate ligament. The visibility was better in 2D TSE and 3D FFE (P 0.04) for cartilage and in VISTA than 3D FFE (P < 0.01) for TFCC. The inter-observer agreement for the visibility of anatomic structures was moderate or substantial. Conclusion: Image quality of 2D TSE was superior to isotropic 3D MR imaging for cartilage, and TFCC. 3D FFE has better visibility for cartilage than VISTA and VISTA has superior visibility for

  5. Qualitative and quantitative assessment of wrist MRI at 3.0T - Comparison between isotropic 3D turbo spin echo and isotropic 3D fast field echo and 2D turbo spin echo

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Jee Young [Dept. of Radiology, Chungang Univ. Hospital, School of Medicine, Chungang Univ. (Korea, Republic of); Yoon, Young Cheol [Dept. of Radiology, Samsung Medical Center, School of Medicine, Sungkyunkwan Univ. (Korea, Republic of)], e-mail: ycyoon@skku.edu; Jung, Jin Young [Dept. of Radiology, Saint Paul' s Hospital, The Catholic Univ. (Korea, Republic of); Choe, Bong-Keun [Dept. of Preventive Medicine, School of Medicine, Kyung Hee Univ., Seoul (Korea, Republic of)

    2013-04-15

    Background: Isotropic three-dimensional (3D) magnetic resonance imaging (MRI) has been applied to various joints. However, comparison for image quality between isotropic 3D MRI and two-dimensional (2D) turbo spin echo (TSE) sequence of the wrist at a 3T MR system has not been investigated. Purpose: To compare the image quality of isotropic 3D MRI including TSE intermediate-weighted (VISTA) sequence and fast field echo (FFE) sequence with 2D TSE intermediate-weighted sequence of the wrist joint at 3.0 T. Material and Methods: MRI was performed in 10 wrists of 10 healthy volunteers with isotropic 3D sequences (VISTA and FFE) and 2D TSE intermediate-weighted sequences at 3.0 T. The signal-to-noise ratio (SNR) was obtained by imaging phantom and noise-only image. Contrast ratios (CRs) were calculated between fluid and cartilage, triangular fibrocartilage complex (TFCC), and the scapholunate ligament. Two radiologists independently assessed the visibility of TFCC, carpal ligaments, cartilage, tendons and nerves with a four-point grading scale. Statistical analysis to compare CRs (one way ANOVA with a Tukey test) and grades of visibility (Kruskal-Wallis test) between three sequences and those for inter-observer agreement (kappa analysis) were performed. Results: The SNR of 2D TSE (46.26) was higher than those of VISTA (23.34) and 3D FFE (19.41). CRs were superior in 2D TSE than VISTA (P = 0.02) for fluid-cartilage and in 2D TSE than 3D FFE (P < 0.01) for fluid-TFCC. The visibility was best in 2D TSE (P < 0.01) for TFCC and in VISTA (P = 0.01) for scapholunate ligament. The visibility was better in 2D TSE and 3D FFE (P 0.04) for cartilage and in VISTA than 3D FFE (P < 0.01) for TFCC. The inter-observer agreement for the visibility of anatomic structures was moderate or substantial. Conclusion: Image quality of 2D TSE was superior to isotropic 3D MR imaging for cartilage, and TFCC. 3D FFE has better visibility for cartilage than VISTA and VISTA has superior visibility for

  6. Differentiation between hepatic haemangiomas and cysts with an inversion recovery single-shot turbo spin-echo (SSTSE) sequence using the TI nulling value of hepatic haemangioma with sensitivity encoding

    International Nuclear Information System (INIS)

    Katada, Yoshiaki; Nozaki, Miwako; Yasumoto, Mayumi; Ishii, Chikako; Tanaka, Hiroshi; Nakamoto, Kazuya; Ohashi, Isamu

    2010-01-01

    To evaluate the additional value of inversion recovery (IR) single-shot turbo spin-echo (SSTSE) imaging with sensitivity encoding (SENSE) using the inversion time (TI) value of hepatic haemangioma as a supplement to conventional T2-weighted turbo spin-echo (TSE) imaging for the discrimination of hepatic haemangiomas and cysts. A total of 134 lesions (77 hepatic haemangiomas, 57 hepatic cysts) in 59 patients were evaluated. Three readers evaluated these images and used a five-point scale to evaluate the lesion status. A receiver operating characteristic (ROC) analysis and 2 x 2 table analysis were used. The ROC analysis for all the readers and all the cases revealed a significantly higher area under the curve (AUC) for the combination of moderately and heavily T2-weighted TSE with IR-SSTSE images (0.945) than for moderately and heavily T2-weighted TSE images alone (0.894) (P < 0.001). For the combination of T2-weighted TSE with IR-SSTSE versus T2-weighted TSE alone, the 2 x 2 table analysis revealed a higher true-positive rate; this difference was statistically significant (P < 0.0001). The introduction of IR-SSTSE with SENSE sequences significantly improves the diagnostic accuracy of the differentiation of hepatic haemangioma and cysts while increasing the time required for routine abdominal imaging by only 20 s. (orig.)

  7. Breath-hold dark-blood T{sub 2}-weighted MR imaging of the heart. Estimation of optimum preset repetition time

    Energy Technology Data Exchange (ETDEWEB)

    Sakuma, Toshiharu; Yamada, Naoaki; Yamasaki, Hidetoshi; Kita, Yoshinobu; Fujii, Hiroshi [National Cardiovascular Center, Suita, Osaka (Japan)

    1999-03-01

    It has recently become possible to obtain T{sub 2}-weighted images using turbo spin echo with a preparation pulse to inhibit the signal from flowing blood (dark blood turbo spin echo: DB-TSE) during breath holding. In order to obtain higher-quality T{sub 2}-weighted images of the heart, we assessed the optimum preset repetition time (TR preset), the interval between the dark blood preparation pulse and the end of data acquisition on DB-TSE. DB-TSE left ventricular short-axis images were obtained with varying TR presets in eight volunteers. Signal intensity was measured for the myocardium and blood in the left ventricular cavity, and the signal intensity ratio of myocardium to blood was calculated. The optimum TR preset was determined so as to give the highest signal intensity ratio of myocardium to blood. A comparison was made of the myocardium-to-blood ratios between the eight volunteers and nine patients. The optimum TR preset changed according to the cardiac cycle. By using the optimum TR preset, we obtained the peak signal intensity ratios in the volunteers and the patients. By using DB-TSE with the optimum TR preset for the cardiac cycle, we can obtain better quality T{sub 2}-weighted images of the heart. (author)

  8. MRT versus CT in the diagnosis of pneumonia. Evaluation of a T2-weighted utrafast turbo-spin-echo sequence (UTSE)

    International Nuclear Information System (INIS)

    Leutner, C.; Lutterbey, G.; Kuhl, C.K.; Flacke, S.; Schild, H.H.; Glasmacher, A.; Theisen, A.; Wardelmann, E.; Grohe, C.

    1999-01-01

    Purpose: To evaluate a T 2 -weighted URSE sequence for the assessment of pulmonary infiltrations in comparison to CT. Methods: 28 MRT scans of 22 patients with confirmed pneumonia were recorded on a 1.5 Tesla apparatus with an expiratory and diastolic triggered, T 2 -weighted ultrafast-spin-echo sequence in axial slice mode with the following parameters: TR eff /T E /Turbofactor 2000-4000/90 ms/21-23; slice thickness/separation 6/0.6 mm; FOV 360 mm; 24 slices. 24 spiral CTs (sice thickness/table advance: 1-2 mm/10 mm) were available for comparison. The separate evaluation of MRTs and CTs was performed by three radiologists in a consensus procedure with regard to pulmonary lesions (e.g., infiltration, round foci, net patterns) and image quality of the MRTs (4-step scale). Results: In 71% of the cases the CTs and MRTs agreed with the diagnosis and representation of the lesions, in 25% MRT was superior. MRT was better for the detection of pulmonary abscesses. In 93% the image quality of the MRT was very good to good. Conclusions: MRT in the technique presented here is in most cases equal to CT for the detection of pneumonia. Diagnosis of pulmonary abscesses seems to be better with MRT. (orig.) [de

  9. Usefulness of dual echo volumetric isotropic turbo spin echo acquisition (VISTA) in MR imaging of the temporomandibular joint

    International Nuclear Information System (INIS)

    Sugimori, Yuko; Tanaka, Shigeko; Naito, Yukari; Nishimura, Tetsuya; Yamamoto, Akira; Miki, Yukio; Ohfuji, Satoko; Katsumata, Yasutomo

    2013-01-01

    We investigated the ability to detect the articular disk and joint effusion of the temporomandibular joint (TMJ) of a method of dual echo volumetric isotropic turbo spin echo acquisition (DE-VISTA) additional fusion images (AFI). DE-VISTA was performed in the 26 TMJ of 13 volunteers and 26 TMJ of 13 patients. Two-dimensional (2D) dual echo turbo spin echo was performed in the 26 TMJ of 13 volunteers. On a workstation, we added proton density-weighted images (PDWI) and T 2 weighted images (T 2 WI) of the DE-VISTA per voxel to reconstruct DE-VISTA-AFI. Two radiologists reviewed these images visually and quantitatively. Visual evaluation of the articular disk was equivalent between DE-VISTA-AFI and 2D-PDWI. The sliding thin-slab multiplanar reformation (MPR) method of DE-VISTA-AFI could detect all articular disks. The ratio of contrast (CR) of adipose tissue by the articular disk to that of the articular disk itself was significantly higher in DE-VISTA-AFI than DE-VISTA-PDWI (P 2 WI but in only 3 of those joints in 2D-T 2 WI. The CR of joint effusion to adipose tissue on DE-VISTA-AFI did not differ significantly from that on DE-VISTA-PDWI. However, using DE-VISTA-T 2 WI in addition to DE-VISTA-PDWI, we could visually identify joint effusion on DE-VISTA-AFI that could not be identified on DE-VISTA-PDWI alone. DE-VISTA-AFI can depict the articular disk and a small amount of joint effusion by the required plane of MPR using the sliding thin-slab MPR method. (author)

  10. Assessment of the image quality and tumor detectability of breath-hold T2-weighted imaging of liver tumors using a fast gradient MR system

    International Nuclear Information System (INIS)

    Yoshida, Kotaro; Suto, Yuji; Sugihara, Shuji; Tokuda, Yukiko

    1996-01-01

    Fourteen patients with various types of focal liver tumors were imaged with turbo spin-echo (TSE), breath-hold TSE (BH-TSE) and half-Fourier single-shot TSE (HASTE) pulse sequences using a fast gradient magnetic resonance imaging (MRI) system. We compared the T2-weighted images of the liver with the TSE, BH-TSE, HASTE and conventional spin-echo (SE) pulse sequences in order to determine whether those fast T2-weighted images, including fat suppressed images, could replace SE images. In quantitative and qualitative analysis, the fast T2-weighted images were slightly superior to the SE images, but they were inferior in the conspicuousness of liver tumor to the SE images. These findings suggest that the fast T2-weighted images can shorten the examination time of the liver MRI, but cannot replace the T2-weighted SE images because of the low conspicuousness. (author)

  11. Evaluation of iron colloid-enhanced T{sub 2}-weighted fast MR imaging of hepatocellular carcinoma. Comparison of SE, TSE and TGSE sequences

    Energy Technology Data Exchange (ETDEWEB)

    Sugihara, Shuji; Suto, Yuji; Kamba, Masayuki; Yoshida, Kotarou; Ohta, Yoshio [Tottori Univ., Yonago (Japan). Faculty of Medicine

    1996-06-01

    We have applied chondroitin sulfate iron colloid (CSIC) as a contrast agent for MRI in detecting hepatocellular carcinoma (HCC) on conventional spin-echo sequences (SE). In this report, we evaluated CSIC-enhanced T{sub 2}-weighted fast MR imaging of HCC. MR imaging were performed before and after i.v. administration of CSIC in 15 patients with 46 HCCs. T{sub 2}-weighted SE (1800/80/2, 210 x 256 matrix), T{sub 2}-weighted turbo spin-echo (TSE1800) (1800/90/5, echo train length=7, 252 x 256 matrix), TSE (3500/90/5, echo train length=7, 252 x 256 matrix) (TSE7), TSE (3500/99/5, echo train length=11, 242 x 256 matrix) (TSE11) and T{sub 2}-weighted turbo-gradient spine-echo (TGSE) (4500/108/4, echo train length=33, 252 x 256 matrix) images were compared quantitatively and qualitatively. In all sequences, liver signal-to-noise ratio (SNR) was significantly decreased and lesion-to-liver contrast-to-noise ratio (CNR) was significantly increased after CSIC administration. Although decreased ratio in liver and tumor SNR caused by CSIC was smaller on TSE sequences compared with SE and TGSE, increased ratio in lesion-to-liver CNR was largest on TSE7. Either before or after i.v. administration of CSIC, the number of detectable lesions was largest on TSE7. TSE with used longer TR, TE and decreased echo factor was useful method for CSIC-enhanced abdominal MR imaging. (author)

  12. Comparison between T2-weighted MR and contrast-enhanced MR cholangiography in the evaluation of biliary anatomy in liver transplant donor candidates

    International Nuclear Information System (INIS)

    Wang Hong; Mu Xuetao; Wu Chunnan; Dong Yuru; Dong Yue; Zhang Huiqing; Zang Yunjin

    2008-01-01

    Objective: To compare conventional T 2 -weighted MR cholangiography (T 2 WI-MRC) with gadobenate dimeglumine enhanced T 1 -weighted MR cholangiography(CE-MRC) for evalution of biliary anatomy in liver transplant donor candidates. Methods: Thirty-two healthy liver transplant donor candidates were examined with two MR cholangiographic methods. For T 2 WI-MRC, a three-dimensional turbo spin-echo sequence and oblique coronal heavily T 2 -weighted thick-slab turbo spin-echo imaging sequence were performed. For CE-MRC, three-dimensional fat-suppressed spoiled gradient-echo sequences were performed, with a time delay of 60 minutes following the administration of gadobenate dimeglumine. To compare the depiction of biliary duct anatomy and the artifact caused by intestinal liquid and breathing between the two methods. Intraoperative cholangiography was the reference-standard examination. Results: The both methods depicted the biliary anatomy correctly in all 9 cases. The both methods showed the third branches of intrahepatic biliary duct clearly. T 2 WI-MRC showed interhepatic biliary duct before the third branches in 28 cases (87.5%), CE-MRC showed the same finding in 14 eases (43.8%). T 2 WI-MRC showed common bile ducts intermitantly in 2 cases, which were normal in CE-MRC and intraoperative cholangiography. Intestinal liquid affected the image quality of biliary duct in 6 cases (18.8%) performed with T 2 WI-MRC, but none with CE-MRC. The artifacts caused by breathing were not obvious in the either method. Conclusion: T 2 WI-MRC and CE-MRC both can be used to evaluate biliary anatomy of liver transplant donor candidates, but CE-MRC appears to be more accurate than T 2 WI-MRC. (authors)

  13. MRI of the lumbar spine: comparison of 3D isotropic turbo spin-echo SPACE sequence versus conventional 2D sequences at 3.0 T.

    Science.gov (United States)

    Lee, Sungwon; Jee, Won-Hee; Jung, Joon-Yong; Lee, So-Yeon; Ryu, Kyeung-Sik; Ha, Kee-Yong

    2015-02-01

    Three-dimensional (3D) fast spin-echo sequence with variable flip-angle refocusing pulse allows retrospective alignments of magnetic resonance imaging (MRI) in any desired plane. To compare isotropic 3D T2-weighted (T2W) turbo spin-echo sequence (TSE-SPACE) with standard two-dimensional (2D) T2W TSE imaging for evaluating lumbar spine pathology at 3.0 T MRI. Forty-two patients who had spine surgery for disk herniation and had 3.0 T spine MRI were included in this study. In addition to standard 2D T2W TSE imaging, sagittal 3D T2W TSE-SPACE was obtained to produce multiplanar (MPR) images. Each set of MR images from 3D T2W TSE and 2D TSE-SPACE were independently scored for the degree of lumbar neural foraminal stenosis, central spinal stenosis, and nerve compression by two reviewers. These scores were compared with operative findings and the sensitivities were evaluated by McNemar test. Inter-observer agreements and the correlation with symptoms laterality were assessed with kappa statistics. The 3D T2W TSE and 2D TSE-SPACE had similar sensitivity in detecting foraminal stenosis (78.9% versus 78.9% in 32 foramen levels), spinal stenosis (100% versus 100% in 42 spinal levels), and nerve compression (92.9% versus 81.8% in 59 spinal nerves). The inter-observer agreements (κ = 0.849 vs. 0.451 for foraminal stenosis, κ = 0.809 vs. 0.503 for spinal stenosis, and κ = 0.681 vs. 0.429 for nerve compression) and symptoms correlation (κ = 0.449 vs. κ = 0.242) were better in 3D TSE-SPACE compared to 2D TSE. 3D TSE-SPACE with oblique coronal MPR images demonstrated better inter-observer agreements compared to 3D TSE-SPACE without oblique coronal MPR images (κ = 0.930 vs. κ = 0.681). Isotropic 3D T2W TSE-SPACE at 3.0 T was comparable to 2D T2W TSE for detecting foraminal stenosis, central spinal stenosis, and nerve compression with better inter-observer agreements and symptom correlation. © The Foundation Acta Radiologica 2014 Reprints and

  14. Evaluation with fat-suppression fast spin-echo T2-weighted images for bone and soft tissue disorders

    International Nuclear Information System (INIS)

    Kakitsubata, Yousuke; Watanabe, Katsushi; Kakitsubata, Sachiko; Shimizu, Tokiyoshi.

    1997-01-01

    One hundred and sixty-four magnetic resonance (MR) studies of bone or soft tissue disorders were evaluated with T2-weighted fast spin echo (FSE) imaging and T2-weighted fat-suppressed FSE (FS-FSE) imaging. Fifty-two patients with bone contusion of the knee were also evaluated with conventional T2-weighted SE imaging and T2-weighted FS-FSE imaging. In 50 of 71 patients (70.4%), areas of high signal intensity in bone marrow were more clearly demonstrated on T2-weighted FS-FSE images than on T2-weighted FSE image. Edema or inflammation of soft tissues were also clearly revealed on T2-weighted FS-FSE images. In 27 of 32 patients (84%), bone contusions were more apparently shown on T2-weighted FS-FSE images than on conventional T2-weighted SE image. T2-weighted FS-FSE imaging is a sensitive method of evaluating the long T2 lesions of bone or soft tissue disorders. (author)

  15. Bilateral Pulvinar Signal Intensity Decrease on T2-Weighted Images in Patients with Aspartylglucosaminuria

    International Nuclear Information System (INIS)

    Autti, T.; Loennqvist, T.; Joensuu, R.

    2008-01-01

    Background: Aspartylglucosaminuria (AGU) is an autosomal recessive lysosomal disease caused by deficiency of aspartylglucosaminidase. A thalamic T2 signal intensity decrease is associated with lysosomal diseases. Purpose: To investigate thalamic signal intensity in AGU by performing a retrospective review of brain magnetic resonance (MR) imaging studies of AGU patients. Material and Methods: A total of 25 MR examinations were available for 11 patients aged between 3 and 32 years (four patients underwent bone marrow transplantation). Of these, 13 examinations were performed after bone marrow transplantation. Five patients had from two to six examinations, and six patients had one examination each. In every patient, the diagnosis of AGU was confirmed by blood and urine tests. Eighteen examinations were performed with a 1.0T imager including dual spin-echo T2 and proton density (PD) axial and coronal images, and 10 examinations also included T1-weighted images. Seven examinations were performed with a 1.5T imager including turbo spin-echo axial and coronal T2-weighted images and axial fluid-attenuated inversion recovery (FLAIR) images; three examinations included T1-weighted three-dimensional magnetization-prepared rapid acquisition gradient-echo (3D MPRAGE) images. The signal intensity of the thalamus and pulvinar in every sequence was compared to that of the putamina. Results: In AGU, thalamic alterations were first detectable on T2-weighted images (25 examinations in 11 patients) from the age of 3 years 6 months, showing decreased signal intensity in 21 of 24 examinations. T1-weighted images (13 examinations) showed slightly increased thalamic signal intensity in five out of seven examinations from the age of 7 years, and PD images (19 examinations) showed decreased signal intensity from the age of 16 years (three examinations). The pulvinar showed decreased signal intensity on spin-echo T2-weighted images for 14 of 18 examinations or on FLAIR sequences for seven

  16. Reticuloendothelial negative contrast media for hepatocellular carcinoma. Initial comparison of chondroitin sulfate iron colloid and Ferrixan in fast T2-weighted MR imaging

    International Nuclear Information System (INIS)

    Sugihara, Shuji; Suto, Yuji; Kamba, Masayuki; Yoshida, Kotaro

    1996-01-01

    Chondroitin sulfate iron colloid (CSIC), a paramagnetic substance, and Ferrixan (SHU555A), a superparamagnetic substance, were administered to 20 patients with 26 nodules of hepatocellular carcinoma, and the visualization of the lesions by fast T2-weighted magnetic resonance imaging (MRI) was quantitatively evaluated. Conventional spin-echo (CSE), turbo spin-echo (TSE), and turbo gradient spin-echo (TGSE) sequences were performed in all patients before and after the administration of the iron colloid preparations. The signal-to-noise ratio (SNR) in the liver decreased significantly after administration of iron colloid preparations by all sequences and at all doses. A reduction in SNR in the liver similar to that obtained with SHU555A could be obtained by increasing the dose of CSIC, which has a weaker T2-shortening effect. In the TSE sequence with a weaker susceptibility effect, the decrease in SNR in the liver tended to be equalized to those in the CSE or TGSE sequences by high dose administration of the iron colloid preparation. We think perhaps that the imaging ability for hepatocellular carcinoma, similar to that of superparamagnetic contrast media, can be obtained with paramagnetic CSIC by administering it at a higher dose. (author)

  17. Reticuloendothelial negative contrast media for hepatocellular carcinoma. Initial comparison of chondroitin sulfate iron colloid and Ferrixan in fast T2-weighted MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sugihara, Shuji; Suto, Yuji; Kamba, Masayuki; Yoshida, Kotaro [Tottori Univ., Yonago (Japan). Faculty of Medicine

    1996-11-01

    Chondroitin sulfate iron colloid (CSIC), a paramagnetic substance, and Ferrixan (SHU555A), a superparamagnetic substance, were administered to 20 patients with 26 nodules of hepatocellular carcinoma, and the visualization of the lesions by fast T2-weighted magnetic resonance imaging (MRI) was quantitatively evaluated. Conventional spin-echo (CSE), turbo spin-echo (TSE), and turbo gradient spin-echo (TGSE) sequences were performed in all patients before and after the administration of the iron colloid preparations. The signal-to-noise ratio (SNR) in the liver decreased significantly after administration of iron colloid preparations by all sequences and at all doses. A reduction in SNR in the liver similar to that obtained with SHU555A could be obtained by increasing the dose of CSIC, which has a weaker T2-shortening effect. In the TSE sequence with a weaker susceptibility effect, the decrease in SNR in the liver tended to be equalized to those in the CSE or TGSE sequences by high dose administration of the iron colloid preparation. We think perhaps that the imaging ability for hepatocellular carcinoma, similar to that of superparamagnetic contrast media, can be obtained with paramagnetic CSIC by administering it at a higher dose. (author)

  18. Value of Fat-Suppressed Proton-Density-Weighted Turbo Spin-Echo Sequences in Detecting Meniscal Lesions: Comparison with Arthroscopy

    International Nuclear Information System (INIS)

    Schaefer, F.K.W.; Schaefer, P.J.; Brossmann, J.; Frahm, C.; Hilgert, R.E.; Heller, M.; Jahnke, T.

    2006-01-01

    Purpose: To evaluate fat-suppressed (FS) proton-density-weighted (PDw) turbo spin-echo (TSE) magnetic resonance imaging (MRI) compared to arthroscopy in the detection of meniscal lesions. Material and Methods: In a prospective study, 31 knee joints were imaged on a 1.5T MR scanner before arthroscopy using the following sequences: (a) coronal and sagittal FS-PDw TSE (TR/TE: 4009/15 ms); (b) coronal T1w SE (TR/TE: 722/20 ms), and sagittal PDw TSE (TR/TE: 3800/15 ms). Other imaging parameters were: slice thickness 3 mm, FOV 160 mm, matrix 256x256. A total of 186 meniscal regions (62 menisci; anterior horn, body, posterior horn) were evaluated. Standard of reference was arthroscopy. Sensitivity, specificity, negative predictive value (npv), positive predictive value (ppv), and accuracy were calculated. Results: Arthroscopically, meniscal lesions were detected in 55/186 segments (35 medial and 20 lateral meniscal lesions). Sensitivity, specificity, npv, ppv, and accuracy for combination of coronal and sagittal FS PDw TSE were 91.4%, 98.3%, 95%, 97%, and 93.5% for the medial meniscus, and 90%, 98.6%, 97.3%, 94.7%, and 96.8% for the lateral. The results were comparable to the combination of coronal T1w SE and sagittal PDw TSE for the medial (88.6%, 98.3%, 93.4%, 96.9%, 91.4%) and the lateral (90%, 95.9%, 97.2%, 85.7%, 92.5%) meniscus. Conclusion: FS PDw TSE-MR sequences are an excellent alternative for the detection of meniscal lesions in comparison with diagnostic arthroscopy

  19. 3D isotropic T2-weighted fast spin echo (VISTA) versus 2D T2-weighted fast spin echo in evaluation of the calcaneofibular ligament in the oblique coronal plane.

    Science.gov (United States)

    Park, H J; Lee, S Y; Choi, Y J; Hong, H P; Park, S J; Park, J H; Kim, E

    2017-02-01

    To investigate whether the image quality of three-dimensional (3D) volume isotropic fast spin echo acquisition (VISTA) magnetic resonance imaging (MRI) of the calcaneofibular ligament (CFL) view is comparable to that of 2D fast spin echo T2-weighted images (2D T2 FSE) for the evaluation of the CFL, and whether 3D VISTA can replace 2D T2 FSE for the evaluation of CFL injuries. This retrospective study included 76 patients who underwent ankle MRI with CFL views of both 2D T2 FSE MRI and 3D VISTA. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of both techniques were measured. The anatomical identification score and diagnostic performances were evaluated by two readers independently. The diagnostic performances of 3D VISTA and 2D T2 FSE were analysed by sensitivity, specificity, and accuracy for diagnosing CFL injury with reference standards of surgically or clinically confirmed diagnoses. Surgical correlation was performed in 29% of the patients, and clinical examination was used in those who did not have surgery (71%). The SNRs and CNRs of 3D VISTA were significantly higher than those of 2D T2 FSE. The anatomical identification scores on 3D VISTA were inferior to those on 2D T2 FSE, and the differences were statistically significant (pT2 FSE for the anatomical evaluation of CFL, 3D VISTA has a diagnostic performance comparable to that of 2D T2 FSE for the diagnosis of CFL injuries. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  20. Improved imaging of cochlear nerve hypoplasia using a 3-Tesla variable flip-angle turbo spin-echo sequence and a 7-cm surface coil.

    Science.gov (United States)

    Giesemann, Anja M; Raab, Peter; Lyutenski, Stefan; Dettmer, Sabine; Bültmann, Eva; Frömke, Cornelia; Lenarz, Thomas; Lanfermann, Heinrich; Goetz, Friedrich

    2014-03-01

    Magnetic resonance imaging of the temporal bone has an important role in decision making with regard to cochlea implantation, especially in children with cochlear nerve deficiency. The purpose of this study was to evaluate the usefulness of the combination of an advanced high-resolution T2-weighted sequence with a surface coil in a 3-Tesla magnetic resonance imaging scanner in cases of suspected cochlear nerve aplasia. Prospective study. Seven patients with cochlear nerve hypoplasia or aplasia were prospectively examined using a high-resolution three-dimensional variable flip-angle turbo spin-echo sequence using a surface coil, and the images were compared with the same sequence in standard resolution using a standard head coil. Three neuroradiologists evaluated the magnetic resonance images independently, rating the visibility of the nerves in diagnosing hypoplasia or aplasia. Eight ears in seven patients with hypoplasia or aplasia of the cochlear nerve were examined. The average age was 2.7 years (range, 9 months-5 years). Seven ears had accompanying malformations. The inter-rater reliability in diagnosing hypoplasia or aplasia was greater using the high-resolution three-dimensional variable flip-angle turbo spin-echo sequence (fixed-marginal kappa: 0.64) than with the same sequence in lower resolution (fixed-marginal kappa: 0.06). Examining cases of suspected cochlear nerve aplasia using the high-resolution three-dimensional variable flip-angle turbo spin-echo sequence in combination with a surface coil shows significant improvement over standard methods. © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  1. Fast FLAIR MR imaging finidngs of cerebral infarction : comparison with T2-weighted spin echo imaging

    International Nuclear Information System (INIS)

    Kong, Keun Young; Choi, Woo Suk; Kim, Eui Jong

    1997-01-01

    To evaluate the utility of FLAIR(Fluid Attenuated Inversion Recovery) MR imaging in cerebral infarction by comparing its results with those of T2-weighted spin-echo imaging. We retrospectively evaluated fast FLAIR images and conventional spin echo images of 82 patients (47 men and 20 women ; median age 60.9 years) with cerebral infarction. MR imaging used a 1.5T MR unit with conventional T2(TR 3900, TE 90) and fast FLAIR sequence (TR 8000, TE 105, TI 2400). We analysed the size of the main lesion and number of lesions, and discrimination between old and new lesions and between small infarction and perivascular space. When T2-weighted and FLAIR imaging were compared, the latter showed that the main lesion was larger in 38 cases (46%), similar in 38 (46%), and smaller in six (7%). The number of lesions was greater in 23 cases(28%), similar in 52 (63%), and fewer in seven (9%). FLAIR images discriminated between old and new lesions in 31 cases ; perivascular space and small infarotion were differentiated in eight cases, and CSF inflowing artifact was observed in 66 (80%). In the diagnosis of cerebral infaretion, fast FLAIR provides images that are equal or superior to T2-weighted images. The fast FLAIR sequence may therefore be used as a part of routine MR brain study in the diagnosis of cerebral infarction

  2. Turbo-Proton Echo Planar Spectroscopic Imaging (t-PEPSI) MR technique in the detection of diffuse axonal damage in brain injury. Comparison with Gradient-Recalled Echo (GRE) sequence.

    Science.gov (United States)

    Giugni, E; Sabatini, U; Hagberg, G E; Formisano, R; Castriota-Scanderbeg, A

    2005-01-01

    Diffuse axonal injury (DAI) is a common type of primary neuronal injury in patients with severe traumatic brain injury, and is frequently accompanied by tissue tear haemorrhage. The T2*-weighted gradient-recalled echo (GRE) sequences are more sensitive than T2-weighted spin-echo images for detection of haemorrhage. This study was undertaken to determine whether turbo-PEPSI, an extremely fast multi-echo-planar-imaging sequence, can be used as an alternative to the GRE sequence for detection of DAI. Nineteen patients (mean age 24,5 year) with severe traumatic brain injury (TBI), occurred at least 3 months earlier, underwent a brain MRI study on a 1.5-Tesla scanner. A qualitative evaluation of the turbo-PEPSI sequences was performed by identifying the optimal echo time and in-plane resolution. The number and size of DAI lesions, as well as the signal intensity contrast ratio (SI CR), were computed for each set of GRE and turbo-PEPSI images, and divided according to their anatomic location into lobar and/or deep brain. There was no significant difference between GRE and turbo-PEPSI sequences in the total number of DAI lesions detected (283 vs 225 lesions, respectively). The GRE sequence identified a greater number of hypointense lesions in the temporal lobe compared to the t-PEPSI sequence (72 vs 35, pPEPSI than for the GRE sequence (pPEPSI sequence can be used as an alternative to the GRE to assess brain DAI in severe TBI patients, especially if uncooperative and medically unstable.

  3. Comparison of spin echo T1-weighted sequences versus fast spin-echo proton density-weighted sequences for evaluation of meniscal tears at 1.5 T

    International Nuclear Information System (INIS)

    Wolff, Andrew B.; Pesce, Lorenzo L.; Wu, Jim S.; Smart, L.R.; Medvecky, Michael J.; Haims, Andrew H.

    2009-01-01

    At our institution, fast spin-echo (FSE) proton density (PD) imaging is used to evaluate articular cartilage, while conventional spin-echo (CSE) T1-weighted sequences have been traditionally used to characterize meniscal pathology. We sought to determine if FSE PD-weighted sequences are equivalent to CSE T1-weighted sequences in the detection of meniscal tears, obviating the need to perform both sequences. We retrospectively reviewed the records of knee arthroscopies performed by two arthroscopy-focused surgeons from an academic medical center over a 2-year period. The preoperative MRI images were interpreted independently by two fellowship-trained musculoskeletal radiologists who graded the sagittal CSE T1 and FSE PD sequences at different sittings with grades 1-5, where 1 = normal meniscus, 2 = probable normal meniscus, 3 indeterminate, 4 = probable torn meniscus, and 5 = torn meniscus. Each meniscus was divided into an anterior and posterior half, and these halves were graded separately. Operative findings provided the gold standard. Receiver operating characteristic (ROC) analysis was performed to compare the two sequences. There were 131 tears in 504 meniscal halves. Using ROC analysis, the reader 1 area under curve for FSE PD was significantly better than CSE T1 (0.939 vs. 0.902, >95% confidence). For reader 2, the difference met good criteria for statistical non-inferiority but not superiority (0.913 for FSE PD and 0.908 for CSE T1; >95% non-inferiority for difference at most of -0.027). FSE PD-weighted sequences, using our institutional protocol, are not inferior to CSE T1-weighted sequences for the detection of meniscal tears and may be superior. (orig.)

  4. Comparison of fast spin echo, fast multiplanner spoiled gradient recalled and conventional T1 and T2 weighted imaging for experimentally induced hepatic tumors in rats

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myeong Jin; Lee, Jong Tae; Suh, Jin Suk; Choi, Pil Sik; Lee, Yeon Hee; Yoo, Hyung Sik; Kim, Ki Whang [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1994-10-15

    To compare the ability of tumor detection and the lesion conspicuity between T1- and T2-weighted fast scanning sequence and T1- and T2-weighted conventional spin echo techniques in MR imaging of hepatic tumors. Hepatic tumors were induced on 13 male Sprague-Dawley rats by feeding 3'-methyl-dimethylethyl aminoazobenzene mixed with Miller's III formula for 12 weeks. MR images were obtained with 1.5 T magnet with dual TMJ coil(Sigma, GE Medical systems, Milwaukee, USA). Animals were anesthetized with 150 mg/kg of ketamine hydrochloride. T2 weighted fast spin echo(FSE), conventional spin echo(CSE) T2- and T1WI, fast multiplanner spoiled gradient recalled(FMPSPGR) imaging were obtained. Number of detected tumors and contrast-to-noise ratio of the tumors were compared for each sequence. Overall 110 tumors were developed. 75% of the tumors were detected on FSE. 65% on FMPSPGR, 41% on conventional T2WI, and 41% on T1WI images. For tumors more than 5 mm in diameter, sensitivity was 88% on FMPSPGR, 65% on conventional T2WI, and 81% on T1WI images respectively. CNR of the tumor was 28.94 {+-} 21.6 on FSE, 13.57 {+-} 8.64 on FMPSPGR, 12.62 {+-} 10.65 on CSE T2WI, and 9.47 {+-} 8.05 on CSE T1WI images, which was significantly high on FSE(p<0.05). Fast spin echo T2WI shows highest sensitivity and tumor-to-liver contrast. FMPSPGR imaging is also favorably comparable with conventional T1WI. Therefore, these two pulse sequences can be useful in clinical condition for hepatic MR imaging.

  5. SLAP tears: diagnosis using 3-T shoulder MR arthrography with the 3D isotropic turbo spin-echo space sequence versus conventional 2D sequences

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Joon-Yong; Jee, Won-Hee; Park, Michael Yong [The Catholic University of Korea, Department of Radiology, Seoul St. Mary' s Hospital, College of Medicine, Seoul (Korea, Republic of); Lee, So-Yeon [Sungkyunkwan University School of Medicine, Department of Radiology, Kangbuk Samsung Hospital, Seoul (Korea, Republic of); Kim, Yang-Soo [The Catholic University of Korea, Department of Orthopaedic Surgery, Seoul St. Mary' s Hospital, College of Medicine, Seoul (Korea, Republic of)

    2013-02-15

    The aim of this study was to determine the accuracy and reliability of shoulder magnetic resonance (MR) arthrography with three-dimensional (3D) isotropic intermediate-weighted turbo spin-echo (TSE) sampling perfection with application-optimised contrasts using different flip angle evolution (SPACE) in the diagnosis of superior labrum anterior-to-posterior (SLAP) lesions compared with two-dimensional (2D) TSE at 3.0 T. MR arthrograms, including 2D TSE and 3D TSE-SPACE, in 87 patients who underwent arthroscopy were retrospectively analysed by two reviewers for the presence and type of SLAP lesions. Sensitivity and specificity were compared using McNemar's test, and inter-observer agreement was calculated using Cohen's kappa. Receiver operating characteristic (ROC) curve analyses were performed. The mean sensitivity, specificity and accuracy were 90%, 85% and 86% for 2D TSE, and 81%, 86% and 85% for 3D TSE-SPACE respectively, with no statistically significant differences. Inter-observer agreements were substantial in 2D TSE ({kappa} = 0.76) and 3D TSE-SPACE ({kappa} = 0.68). The areas under the ROC curves were 0.92 for 2D TSE and 0.90 for 3D TSE-SPACE, which were not significantly different. MR arthrography with 3D TSE-SPACE showed comparable accuracy and substantial inter-observer agreement for the diagnosis of SLAP lesions circle MR arthrography is regarded as the definitive method of shoulder imaging circle Different MR sequences are evolving for SLAP lesions circle 3D TSE-SPACE demonstrated comparable overall accuracy to 2D TSE for SLAP lesions. (orig.)

  6. Utility of dual echo T2-weighted turbo spin echo MR imaging for differentiation of solid, malignant hepatic lesions from nonsolid, benign hepatic lesions

    International Nuclear Information System (INIS)

    Yang, Dal Mo; Yoon, Myung Hwan; Kim, Hak Soo; Lee, Eun Joo; Kim, Jong Ho; Kim, Hyung Sik; Chung, Jin Woo

    1999-01-01

    To evaluate the additive value of multiphasic contrast-enhanced dynamic MR imaging as a supplement to dual-echo T2-weighted TSE MR imaging for the differentiation of solid, malignant hepatic lesions from nonsolid, benign hepatic lesions. Two radiologists retrospectively reviewed dual-echo T2-weighted TSE MR images and gadolinium-enhanced MR images in 51 patients with hepatic lesions (28 malignant, 69 benign). For the differentiation of malignant from benign lesions, as seen on dual-echo T2-weighted TSE MR images, we evaluated sensitivity, specificity, and accuracy, and compared with the results with those for dual echo T2-weighted MR images plus multiphasic contrast-enhanced dynamic MR images. In addition, Az values for dual echo T2-weighted MR images were compared with those for dual echo T2-weighted MR images plus multiphasic contrast-enhanced dynamic MR images. For the differentiation of malignant from benign hepatic lesions, as seen on dual-echo T2-weighted TSE images, sensitivity, specificity, and accuracy were 80.0%, 97.5%, and 93.9%, respectively, for lesions less than 3cm in diameter, and 92.3%, 95.0%, and 93.5%, respectively, for those that were 3cm or larger. The results for dual-echo T2-weighted MR imaging plus multiphasic contrast-enhanced dynamic MR imaging were 86.7%, 100.0%, and 97.3%, respectively, for lesions less than 3cm, and 92.3%, 100.0%, and 95.7%, respectively for those that were 3cm or larger. There were no significant differences in sensitivity, specificity, or accuracy between the results obtained using dual-echo T2-weighted MR imaging and those obtained with dual-echo T2-weighted MR imaging plus multiphasic contrast-enhanced dynamic MR imaging. Nor were these statistically significant differences in Az values between the two groups. For the differentiation of solid, malignant hepatic lesions from nonsolid, benign hepatic lesions, there is no difference in accuracy between dual-echo T2-weighted TSE MR imaging and the additional use of

  7. SNR-optimized phase-sensitive dual-acquisition turbo spin echo imaging: a fast alternative to FLAIR.

    Science.gov (United States)

    Lee, Hyunyeol; Park, Jaeseok

    2013-07-01

    Phase-sensitive dual-acquisition single-slab three-dimensional turbo spin echo imaging was recently introduced, producing high-resolution isotropic cerebrospinal fluid attenuated brain images without long inversion recovery preparation. Despite the advantages, the weighted-averaging-based technique suffers from noise amplification resulting from different levels of cerebrospinal fluid signal modulations over the two acquisitions. The purpose of this work is to develop a signal-to-noise ratio-optimized version of the phase-sensitive dual-acquisition single-slab three-dimensional turbo spin echo. Variable refocusing flip angles in the first acquisition are calculated using a three-step prescribed signal evolution while those in the second acquisition are calculated using a two-step pseudo-steady state signal transition with a high flip-angle pseudo-steady state at a later portion of the echo train, balancing the levels of cerebrospinal fluid signals in both the acquisitions. Low spatial frequency signals are sampled during the high flip-angle pseudo-steady state to further suppress noise. Numerical simulations of the Bloch equations were performed to evaluate signal evolutions of brain tissues along the echo train and optimize imaging parameters. In vivo studies demonstrate that compared with conventional phase-sensitive dual-acquisition single-slab three-dimensional turbo spin echo, the proposed optimization yields 74% increase in apparent signal-to-noise ratio for gray matter and 32% decrease in imaging time. The proposed method can be a potential alternative to conventional fluid-attenuated imaging. Copyright © 2012 Wiley Periodicals, Inc.

  8. High-resolution heavily T2-weighted magnetic resonance imaging for evaluation of the pituitary stalk in children with ectopic neurohypophysis

    Energy Technology Data Exchange (ETDEWEB)

    Sanharawi, Imane El; Tzarouchi, Loukia [Hopital Robert Debre, APHP, Service de Radiologie Pediatrique, Paris (France); Cardoen, Liesbeth [Hopital Robert Debre, APHP, Service de Radiologie Pediatrique, Paris (France); Universite Paris Diderot, Paris (France); Martinerie, Laetitia; Leger, Juliane; Carel, Jean-Claude [Universite Paris Diderot, Paris (France); Inserm U1141, DHU PROTECT, Paris (France); Hopital Robert Debre, APHP, Service d' Endocrinologie Pediatrique, Paris (France); Elmaleh-Berges, Monique [Hopital Robert Debre, APHP, Service de Radiologie Pediatrique, Paris (France); Inserm U1141, DHU PROTECT, Paris (France); Alison, Marianne [Hopital Robert Debre, APHP, Service de Radiologie Pediatrique, Paris (France); Universite Paris Diderot, Paris (France); Inserm U1141, DHU PROTECT, Paris (France)

    2017-05-15

    In anterior pituitary deficiency, patients with non visible pituitary stalk have more often multiple deficiencies and persistent deficiency than patients with visible pituitary stalk. To compare the diagnostic value of a high-resolution heavily T2-weighted sequence to 1.5-mm-thick unenhanced and contrast-enhanced sagittal T1-weighted sequences to assess the presence of the pituitary stalk in children with ectopic posterior pituitary gland. We retrospectively evaluated the MRI data of 14 children diagnosed with ectopic posterior pituitary gland between 2010 and 2014. We evaluated the presence of a pituitary stalk using a sagittal high-resolution heavily T2-weighted sequence and a 1.5-mm sagittal T1-weighted turbo spin-echo sequence before and after contrast medium administration. A pituitary stalk was present on at least one of the sequences in 10 of the 14 children (71%). T2-weighted sequence depicted the pituitary stalk in all 10 children, whereas the 1.5-mm-thick T1-weighted sequence depicted 2/10 (20%) before contrast injection and 8/10 (80%) after contrast injection (P=0.007). Compared with 1.5-mm-thick contrast-enhanced T1-weighted sequences, high-resolution heavily T2-weighted sequence demonstrates better sensitivity in detecting the pituitary stalk in children with ectopic posterior pituitary gland, suggesting that contrast injection is unnecessary to assess the presence of a pituitary stalk in this setting. (orig.)

  9. High-resolution heavily T2-weighted magnetic resonance imaging for evaluation of the pituitary stalk in children with ectopic neurohypophysis.

    Science.gov (United States)

    El Sanharawi, Imane; Tzarouchi, Loukia; Cardoen, Liesbeth; Martinerie, Laetitia; Leger, Juliane; Carel, Jean-Claude; Elmaleh-Berges, Monique; Alison, Marianne

    2017-05-01

    In anterior pituitary deficiency, patients with non visible pituitary stalk have more often multiple deficiencies and persistent deficiency than patients with visible pituitary stalk. To compare the diagnostic value of a high-resolution heavily T2-weighted sequence to 1.5-mm-thick unenhanced and contrast-enhanced sagittal T1-weighted sequences to assess the presence of the pituitary stalk in children with ectopic posterior pituitary gland. We retrospectively evaluated the MRI data of 14 children diagnosed with ectopic posterior pituitary gland between 2010 and 2014. We evaluated the presence of a pituitary stalk using a sagittal high-resolution heavily T2-weighted sequence and a 1.5-mm sagittal T1-weighted turbo spin-echo sequence before and after contrast medium administration. A pituitary stalk was present on at least one of the sequences in 10 of the 14 children (71%). T2-weighted sequence depicted the pituitary stalk in all 10 children, whereas the 1.5-mm-thick T1-weighted sequence depicted 2/10 (20%) before contrast injection and 8/10 (80%) after contrast injection (P=0.007). Compared with 1.5-mm-thick contrast-enhanced T1-weighted sequences, high-resolution heavily T2-weighted sequence demonstrates better sensitivity in detecting the pituitary stalk in children with ectopic posterior pituitary gland, suggesting that contrast injection is unnecessary to assess the presence of a pituitary stalk in this setting.

  10. High-resolution T{sub 2}-weighted cervical cancer imaging: a feasibility study on ultra-high-field 7.0-T MRI with an endorectal monopole antenna

    Energy Technology Data Exchange (ETDEWEB)

    Hoogendam, Jacob P.; Verheijen, Rene H.M.; Zweemer, Ronald P. [University Medical Centre Utrecht, Department of Gynaecological Oncology, UMC Utrecht Cancer Centre, PO Box 85500, Utrecht (Netherlands); Kalleveen, Irene M.L.; Castro, Catalina S.A. de; Raaijmakers, Alexander J.E.; Bosch, Maurice A.A.J. van den; Klomp, Dennis W.J.; Veldhuis, Wouter B. [University Medical Centre Utrecht, Department of Radiology, Utrecht (Netherlands)

    2017-03-15

    We studied the feasibility of high-resolution T{sub 2}-weighted cervical cancer imaging on an ultra-high-field 7.0-T magnetic resonance imaging (MRI) system using an endorectal antenna of 4.7-mm thickness. A feasibility study on 20 stage IB1-IIB cervical cancer patients was conducted. All underwent pre-treatment 1.5-T MRI. At 7.0-T MRI, an external transmit/receive array with seven dipole antennae and a single endorectal monopole receive antenna were used. Discomfort levels were assessed. Following individualised phase-based B{sub 1} {sup +} shimming, T{sub 2}-weighted turbo spin echo sequences were completed. Patients had stage IB1 (n = 9), IB2 (n = 4), IIA1 (n = 1) or IIB (n = 6) cervical cancer. Discomfort (ten-point scale) was minimal at placement and removal of the endorectal antenna with a median score of 1 (range, 0-5) and 0 (range, 0-2) respectively. Its use did not result in adverse events or pre-term session discontinuation. To demonstrate feasibility, T{sub 2}-weighted acquisitions from 7.0-T MRI are presented in comparison to 1.5-T MRI. Artefacts on 7.0-T MRI were due to motion, locally destructive B{sub 1} interference, excessive B{sub 1} under the external antennae and SENSE reconstruction. High-resolution T{sub 2}-weighted 7.0-T MRI of stage IB1-IIB cervical cancer is feasible. The addition of an endorectal antenna is well tolerated by patients. (orig.)

  11. Experimental acute intracerebral hemorrhage: Value of MR sequences for a safe diagnosis at 1.5 and 0.5 T

    International Nuclear Information System (INIS)

    Kueker, W.; Thron, A.; Thiex, R.; Rohde, I.; Rohde, V.

    2000-01-01

    To determine the detectability of intracerebral hematomas with MR imaging at 1.5 T and 0.5 T with fluid attenuated inversion recovery turbo spin-echo (FLAIR) and gradient-echo sequences. Material and Methods: Twenty-seven intracerebral hematomas were created in 25 piglets by injection of venous blood into the brain through a burr hole. All were imaged with T2*-weighted gradient echo sequences (fast field echo, FFE), T2-weighted fluid attenuated inversion recovery turbo spin-echo sequences (FLAIR), T2-weighted turbo spin-echo (TSE) and T1-weighted spin-echo sequences. Follow-up was performed on the 2nd, 4th and 10th postoperative days. Ten animals were additionally investigated with similar sequences at 0.5 T. Histologic correlation was obtained in all cases. Results: T2* FFE sequences detected all acute intracerebral hematomas and demonstrated the size correctly at 1.5 T and 0.5 T. The conspicuity was better at 1.5 T. FLAIR sequences were unreliable in the hyperacute phase at 1.5 T. However, subarachnoid and intraventricular extension was best appreciated with FLAIR images. T2 TSE images were incapable of detecting para ventricular and subarachnoid hemorrhages, but clearly demonstrated intracerebral blood in other locations. T1-weighted images were insensitive to hemorrhage in the acute state but very useful in subacute and chronic hematomas. Conclusion: The safe and reliable diagnosis of intracerebral hemorrhage is probably possible with MR imaging at 1.5 T and 0.5 T even of hematomas less than 90 min old, but requires the application of at least FLAIR, T2* FFE and T1 sequences and is therefore time consuming

  12. MRI of normal pancreas : comparison of T2-weighted pulse sequences using turbo spin echo, turbo spin echo with fat suppression, HASTE and HASTE with fat suppression

    International Nuclear Information System (INIS)

    Lee, Kyoung Ho; Kim, Tae Kyoung; Jang, Hyun Jung; Kim, Young Hoon; Han, Sang Wook; Han, Joon Koo; Choi, Byung Ihn

    1998-01-01

    To compare various breath-hold T2 weighted sequences in imaging normal pancreas with a phased-array coil. HASTE showed higher SD/N than TSE or FS-HASTE (p<0.01). TSE was superior to TSE in the delineation of pancreatic duct (p<0.001). TSE showed more artifacts than FS-TSE (p<0.001): HASTE and FS-HASTE showed no artifact. TSE is better than HASTE for the delineation of pancreatic margin but HASTE shows less artifacts and a more conspicuous pancreatic duct. Fat suppression decreases artifacts but makes the pancreatic margin indistinct. (author). 19 refs., 1 tab., 2 figs

  13. Comparison of 3D turbo spin-echo SPACE sequences with conventional 2D MRI sequences to assess the shoulder joint

    Energy Technology Data Exchange (ETDEWEB)

    Kloth, Jost Karsten, E-mail: jost.kloth@med.uni-heidelberg.de [Diagnostic and Interventional Radiology, University Hospital Heidelberg, Im Neuenheimer Feld 110, D-69120 Heidelberg (Germany); Winterstein, Marianne, E-mail: marianne.winterstein@med.uni-heidelberg.de [Diagnostic and Interventional Radiology, University Hospital Heidelberg, Im Neuenheimer Feld 110, D-69120 Heidelberg (Germany); Akbar, Michael, E-mail: michael.akbar@med.uni-heidelberg.de [Orthopedic and Trauma Surgery, University Hospital Heidelberg, Schlierbacher Landstraße 200a, D-69118 Heidelberg (Germany); Meyer, Esther, E-mail: esther.meyer@siemens.com [Siemens Healthcare, Erlangen (Germany); Paul, Dominik, E-mail: dominik.paul@siemens.com [Siemens Healthcare, Erlangen (Germany); Kauczor, Haus-Ulrich, E-mail: hans-ulrich.kauczor@med.uni-heidelberg.de [Diagnostic and Interventional Radiology, University Hospital Heidelberg, Im Neuenheimer Feld 110, D-69120 Heidelberg (Germany); Weber, Marc-André, E-mail: marcandre.weber@med.uni-heidelberg.de [Diagnostic and Interventional Radiology, University Hospital Heidelberg, Im Neuenheimer Feld 110, D-69120 Heidelberg (Germany)

    2014-10-15

    Highlights: • 3D SPACE and conventional 2D TSE MRI for assessment of the shoulder joint were compared. • Concordance for most pathologys was substantial to almost perfect. • Examination time could be reduced up to 8 min (27%). • Regarding rotator cuff injuries an additional sagittal T2w TSE sequence in 3D protocol is recommended. - Abstract: Purpose: To determine the accuracy and reliability of three-dimensional (3D) T1- and proton density (PD)-weighted turbo spin-echo (TSE) sampling perfection with application-optimized contrasts using different flip-angle evolution (SPACE) compared with conventional 2D sequences in assessment of the shoulder-joint. Materials and methods: Ninety-three subjects were examined on a 3-T MRI system with both conventional 2D-TSE sequences in T1-, T2- and PD-weighting and 3D SPACE sequences in T1- and PD-weighting. All examinations were assessed independently by two reviewers for common pathologies of the shoulder-joint. Agreement between 2D- and 3D-sequences and inter-observer-agreement was evaluated using kappa-statistics. Results: Using conventional 2D TSE sequences as standard of reference, sensitivity, specificity, and accuracy values of 3D SPACE were 81.8%, 95.1%, and 93.5% for injuries of the supraspinatus-tendon (SSP), 81.3%, 93.5%, and 91.4% for the cartilage layer and 82.4%, 98.5%, and 97.5% for the long biceps tendon. Concordance between 2D and 3D was almost perfect for tendinopathies of the SSP (κ = 0.85), osteoarthritis (κ = 1), luxation of the biceps tendon (κ = 1) and adjacent bone marrow (κ = 0.92). Inter-observer-agreement was generally higher for conventional 2D TSE sequences (κ, 0.23–1.0), when compared to 3D SPACE sequences (κ, −0.33 to 1.0) except for disorders of the long biceps tendon and supraspinatus tendon rupture. Conclusion: Because of substantial and almost perfect concordance with conventional 2D TSE sequences for common shoulder pathologies, MRI examination-time can be reduced by nearly 40

  14. Evaluation of myelination and myelination disorders with turbo inversion recovery magnetic resonance imaging

    International Nuclear Information System (INIS)

    Daldrup, H.E.; Schuierer, G.; Link, T.M.; Moeller, H.; Bick, U.; Peters, P.E.; Kurlemann, G.

    1997-01-01

    The aim of our work was to determine the efficacy of turbo inversion recovery spin echo (TIRSE) pulse sequences in differentiating patients with normal and abnormal myelination. Twenty neurological normal children (aged 5 months to 12 years) as well as 65 children presenting clinically with neurologic developmental deficits (aged 2 months to 10 years) were examined using TIRSE, T1-weighted SE, and T2-weighted turbo SE pulse sequences. Contrast-to-noise-ratio (CNR) between myelinated white and gray matter was compared for the different pulse sequences. In addition, two readers analyzed all images qualitatively by consensus. The CNR values were significantly higher on TIRSE images as compared with conventional images (p < 0.05). Forty-two neurologically abnormal patients displayed a normal myelination on all sequences, whereas 23 showed an abnormal myelination. The TIRSE sequence provided a sensitive and specific depiction of an abnormal myelination in all of these patients. The TIRSE sequence provided additional information to conventional pulse sequences in determining myelination disorders in children, especially in children older than 2 years. (orig.)

  15. Cortical T2 signal shortening in amyotrophic lateral sclerosis is not due to iron deposits

    Energy Technology Data Exchange (ETDEWEB)

    Hecht, M.J.; Neundoerfer, B. [University of Erlangen-Nurenberg, Department of Neurology, Erlangen (Germany); Fellner, C.; Fellner, F.A. [University of Erlangen-Nurenberg, Institute of Diagnostic Radiology, Erlangen (Germany); Landes-Nervenklinik Wagner-Jauregg, Institute of Radiology, Linz (Austria); Schmid, A. [University of Erlangen-Nurenberg, Institute of Diagnostic Radiology, Erlangen (Germany)

    2005-11-01

    Signal shortening of the motor cortex in T2-weighted MR images is a frequent finding in patients with amyotrophic lateral sclerosis (ALS). The cause of signal shortening in ALS is unknown, although iron deposits have been suggested. To test this hypothesis, we acquired T2*-weighted gradient-echo (GRE) MR images in addition to T2-weighted turbo spin-echo in 69 patients with ALS. Signal shortening in T2-weighted images was found in 31 patients. In T2*-weighted GRE images, only three patients had signal shortening. One patient with additional bifrontal haemorrhage had frontal but no motor cortex signal shortening. Iron deposits do not cause cortical signal shortening in patients with ALS predominantly. Other factors are presumably more important in the generation of cortical T2 shortening in ALS. (orig.)

  16. Cortical T2 signal shortening in amyotrophic lateral sclerosis is not due to iron deposits

    International Nuclear Information System (INIS)

    Hecht, M.J.; Neundoerfer, B.; Fellner, C.; Fellner, F.A.; Schmid, A.

    2005-01-01

    Signal shortening of the motor cortex in T2-weighted MR images is a frequent finding in patients with amyotrophic lateral sclerosis (ALS). The cause of signal shortening in ALS is unknown, although iron deposits have been suggested. To test this hypothesis, we acquired T2*-weighted gradient-echo (GRE) MR images in addition to T2-weighted turbo spin-echo in 69 patients with ALS. Signal shortening in T2-weighted images was found in 31 patients. In T2*-weighted GRE images, only three patients had signal shortening. One patient with additional bifrontal haemorrhage had frontal but no motor cortex signal shortening. Iron deposits do not cause cortical signal shortening in patients with ALS predominantly. Other factors are presumably more important in the generation of cortical T2 shortening in ALS. (orig.)

  17. Ultrashort turbo spinecho versus turbo spinecho in the evaluation of musculoskeletal diseases

    International Nuclear Information System (INIS)

    Breitenseher, M.; Kontaxis, G.; Fleischmann, D.; Rand, T.H.; Imhof, H.; Trattnig, S.

    1995-01-01

    Ultrashort turbo spin-echo sequence (TSE) has the advantage of shorter scan times, minimizing motion artifacts, but has the disadvantage of a lower signal-to-noise ratio and suffers from different artifacts. T2-weighted ultrashort TSE (echo train 24) and TSE (echo train 11) were compared in degenerative lesions of the spine (n=9) and ligamentous lesions associated with sprained ankle injuries (n=5). The imaging quality of ultrashort TSE was very similar to TSE. There was no difference in diagnostic reliability with ultrashort TSE compared to TSE in the spine or ankle. With regard to contrast properties a higher signal intensity of fatty bone marrow was obtained with ultrashort TSE, with consecutive lower contrast between fluid and edema on the one hand and fatty tissue on the other. (orig.) [de

  18. Assessment of arterial wall enhancement for differentiation of parent artery disease from small artery disease: Comparison between histogram analysis and visual analysis on 3 dimensional contrast-enhanced T1-weighted turbo spin echo MR images at 3T

    International Nuclear Information System (INIS)

    Jang, Jin Hee; Kim, Tae Won; Hwang, Eo Jin; Choi, Hyun Seok; Koo, Ja Seung; Shin, Yong Sam; Jung, So Lyung; Ahn, Kook Jin; Kim, Bum Soo

    2017-01-01

    The purpose of this study was to compare the histogram analysis and visual scores in 3T MRI assessment of middle cerebral arterial wall enhancement in patients with acute stroke, for the differentiation of parent artery disease (PAD) from small artery disease (SAD). Among the 82 consecutive patients in a tertiary hospital for one year, 25 patients with acute infarcts in middle cerebral artery (MCA) territory were included in this study including 15 patients with PAD and 10 patients with SAD. Three-dimensional contrast-enhanced T1-weighted turbo spin echo MR images with black-blood preparation at 3T were analyzed both qualitatively and quantitatively. The degree of MCA stenosis, and visual and histogram assessments on MCA wall enhancement were evaluated. A statistical analysis was performed to compare diagnostic accuracy between qualitative and quantitative metrics. The degree of stenosis, visual enhancement score, geometric mean (GM), and the 90th percentile (90P) value from the histogram analysis were significantly higher in PAD than in SAD (p = 0.006 for stenosis, < 0.001 for others). The receiver operating characteristic curve area of GM and 90P were 1 (95% confidence interval [CI], 0.86-1.00). A histogram analysis of a relevant arterial wall enhancement allows differentiation between PAD and SAD in patients with acute stroke within the MCA territory

  19. Assessment of arterial wall enhancement for differentiation of parent artery disease from small artery disease: Comparison between histogram analysis and visual analysis on 3 dimensional contrast-enhanced T1-weighted turbo spin echo MR images at 3T

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Jin Hee; Kim, Tae Won; Hwang, Eo Jin; Choi, Hyun Seok; Koo, Ja Seung; Shin, Yong Sam; Jung, So Lyung; Ahn, Kook Jin; Kim, Bum Soo [College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2017-04-15

    The purpose of this study was to compare the histogram analysis and visual scores in 3T MRI assessment of middle cerebral arterial wall enhancement in patients with acute stroke, for the differentiation of parent artery disease (PAD) from small artery disease (SAD). Among the 82 consecutive patients in a tertiary hospital for one year, 25 patients with acute infarcts in middle cerebral artery (MCA) territory were included in this study including 15 patients with PAD and 10 patients with SAD. Three-dimensional contrast-enhanced T1-weighted turbo spin echo MR images with black-blood preparation at 3T were analyzed both qualitatively and quantitatively. The degree of MCA stenosis, and visual and histogram assessments on MCA wall enhancement were evaluated. A statistical analysis was performed to compare diagnostic accuracy between qualitative and quantitative metrics. The degree of stenosis, visual enhancement score, geometric mean (GM), and the 90th percentile (90P) value from the histogram analysis were significantly higher in PAD than in SAD (p = 0.006 for stenosis, < 0.001 for others). The receiver operating characteristic curve area of GM and 90P were 1 (95% confidence interval [CI], 0.86-1.00). A histogram analysis of a relevant arterial wall enhancement allows differentiation between PAD and SAD in patients with acute stroke within the MCA territory.

  20. Comparison of different magnetic resonance cholangiography techniques in living liver donors including Gd-EOB-DTPA enhanced T1-weighted sequences.

    Directory of Open Access Journals (Sweden)

    Sonja Kinner

    Full Text Available Preoperative evaluation of potential living liver donors (PLLDs includes the assessment of the biliary anatomy to avoid postoperative complications. Aim of this study was to compare T2-weighted (T2w and Gd-EOB-DTPA enhanced T1-weighted (T1w magnetic resonance cholangiography (MRC techniques in the evaluation of PLLDs.30 PLLDs underwent MRC on a 1.5 T Magnetom Avanto (Siemens, Erlangen, Germany using (A 2D T2w HASTE (Half Fourier Acquisition Single Shot Turbo Spin Echo fat saturated (fs in axial plane, (B 2D T2w HASTE fs thick slices in coronal plane, (C free breathing 3D T2w TSE (turbo spin echo RESTORE (high-resolution navigator corrected plus (D maximum intensity projections (MIPs, (E T2w SPACE (sampling perfection with application optimized contrasts using different flip angle evolutions plus (F MIPs and (G T2w TSE BLADE as well as Gd-EOB-DTPA T1w images without (G and with (H inversion recovery. Contrast enhanced CT cholangiography served as reference imaging modality. Two independent reviewers evaluated the biliary tract anatomy on a 5-point scale subjectively and objectively. Data sets were compared using a Mann-Whitney-U-test. Kappa values were also calculated.Source images and maximum intensity projections of 3D T2w TSE sequences (RESTORE and SPACE proved to be best for subjective and objective evaluation directly followed by 2D HASTE sequences. Interobserver variabilities were good to excellent (k = 0.622-0.804.3D T2w sequences are essential for preoperative biliary tract evaluation in potential living liver donors. Furthermore, our results underline the value of different MRCP sequence types for the evaluation of the biliary anatomy in PLLDs including Gd-EOB-DTPA enhanced T1w MRC.

  1. Reducing contrast contamination in radial turbo-spin-echo acquisitions by combining a narrow-band KWIC filter with parallel imaging.

    Science.gov (United States)

    Neumann, Daniel; Breuer, Felix A; Völker, Michael; Brandt, Tobias; Griswold, Mark A; Jakob, Peter M; Blaimer, Martin

    2014-12-01

    Cartesian turbo spin-echo (TSE) and radial TSE images are usually reconstructed by assembling data containing different contrast information into a single k-space. This approach results in mixed contrast contributions in the images, which may reduce their diagnostic value. The goal of this work is to improve the image contrast from radial TSE acquisitions by reducing the contribution of signals with undesired contrast information. Radial TSE acquisitions allow the reconstruction of multiple images with different T2 contrasts using the k-space weighted image contrast (KWIC) filter. In this work, the image contrast is improved by reducing the band-width of the KWIC filter. Data for the reconstruction of a single image are selected from within a small temporal range around the desired echo time. The resulting dataset is undersampled and, therefore, an iterative parallel imaging algorithm is applied to remove aliasing artifacts. Radial TSE images of the human brain reconstructed with the proposed method show an improved contrast when compared with Cartesian TSE images or radial TSE images with conventional KWIC reconstructions. The proposed method provides multi-contrast images from radial TSE data with contrasts similar to multi spin-echo images. Contaminations from unwanted contrast weightings are strongly reduced. © 2014 Wiley Periodicals, Inc.

  2. MR imaging of articular cartilage : comparison of magnetization transfer contrast and fat-suppression in multiplanar and 3D gradient-echo, spin-echo, turbo spin-echo techniques

    International Nuclear Information System (INIS)

    Lee, Young Joon; Joo, Eun Young; Eun, Choong Ki

    1999-01-01

    The purpose of this study was to evaluate the effects of magnetization transfer contrast(MTC) and fat-suppression(FS) in variable spin-echo and gradient-echo sequences for articular cartilage imaging and to determine the optimal pulse sequences. Using variable 7-pulse sequences, the knees of 15 pigs were imaged Axial images were obtained using proton density and T2-weighted spin-echo (PDWSE and T2WSE), turbo spin-echo (TSE), multiplanar gradient-echo (MPGR), and 3D steady-state gradient-echo (3DGRE) sequences, and the same pulse sequences were then repeated using MTC. Also T1-weighted spin-echo(T1WSE) and 3D spoiled gradient-echo(3DSPGR) images of knees were also acquired, and the procedure was repeated using FS. For each knee, a total of 14 axial images were acquired, and using a 6-band scoring system, the visibility of and the visibilities of the the articular cartilage was analyzed. The visual effect of MTC and FS was scored using a 4-band scale. For each image, the signal intensities of articular cartilage, subchondral bone, muscles, and saline were measured, and signal-to-noise ratios(SNR) and contrast-to-noise ratios(CNR) were also calculated. Visibility of the cartilage was best when 3DSPGR and T1WSE sequences were used. MTC imaging increased the negative contrast between cartilage and saline, but FS imaging provided more positive contrast. CNR between cartilage and saline was highest when using TSE with FS(-351.1±15.3), though CNR between cartilage and bone then fell to -14.7±10.8. In MTC imaging using MPGR showed the greatest increase of negative contrast between cartilage and saline(CNR change=-74.7); the next highest was when 3DGRE was used(CNR change=-34.3). CNR between cartilage and bone was highest with MPGR(161.9±17.7), but with MTC, the greatest CNR decrease(-81.8) was observed. The greatest CNR increase between cartilage and bone was noted in T1WSE with FS. In all scans, FS provided a cartilage-only positive contrast image, though the absolute

  3. The usefulness of T2-weighted MR urography and contrast enhanced MR urography in the evaluation of obstructive uropathy: comparisonal study with antegrade pyelography

    International Nuclear Information System (INIS)

    Oh, Chang Hoon; Lee, Jeong Min; Jin, Kong Yong; Chung, Gyung Ho; Cho, Seung Il; Lee, Sang Hun; Kim, Young Kon; Oh, Gyung Jae

    2002-01-01

    To compare the efficacy of contrast-enhanced and T2-weighted magnetic resonance urography (MRU) for the depiction of obstruction and evaluation of the causes of obstructive uropathy with that of antegrade pyelography. Twenty-five patients with obstructive uropathy who underwent percutaneous nephrostomy (PCN) and antegrade pyelography( AGP) were included in the study. We performed MR urography, comprising half-Fourier acquisition single-shot turbo spin-echo (HASTE) T2- weighted imaging and 3-D fast imaging with steady state precession (3-D FISP) T1-weighted imaging after gadolinium enhancement and compared the quality of the images of both the HASTE and 3-D FISP MRU technique in terms of their depiction of the dilated pelvocalyceal system, and the level, type, and causes of obstruction. In terms of anatomical depiction of the pelvocalyceal system (p=0.002) and the causes of obstruction (p=0.003). T1-weighted MRU using 3D-FISP was significantly better than T2-weighted MRU using the HASTE sequence. Regarding level of obstruction, T2-weighted MRU using the HASTE sequence and contrast enhanced T1-weighted MRU using 3D-FISP showed an accuracy of 76% (19/25) and 84% (21/25), respectively. In terms of type of obstruction, the accuracy of T2-weighted MRU and T1-weighted CEMRU was 72% (18/25) and 88% (22/25), respectively. T2-weighted MRU and Ta-weighted CEMRU provided both anatomical information and that relating to impaired renal function. The two modelities played a complementary role and their use could decrease the unnecessary use of invasive diagnostic examination for the evaluation of obstructive uropathy

  4. MR imaging pulse sequence rationale: SD-, T1-, and T2-weighted images

    International Nuclear Information System (INIS)

    Sax, S.; Weathers, S.W.; Schneiders, N.J.; Horowitz, B.L.; Mawad, M.E.; Sandlin, M.E.; Blackwell, R.; Bryan, R.N.

    1986-01-01

    Over 500 patients have been examined with a pulse sequence designed to provide spin-density (SD)-weighted images (TR=3 sec, TE=35 msec), T1-weighted images (TR=0.3 sec, TE=35msec), and T2-weighted images (TR=3 sec, TE=105 msec) from which calculated ''synthesized'' images and SD, T1, and T2 calculated images could be obtained. Each image contributes unique information. SD-weighted images optimally display anatomy and often best highlight pathology. T1-weighted images are critical in assessing cerebral hemorrhages. T2-weighted images best display most lesions, but yield incomplete information in 35% of cases. All three types of ''weighted'' images are necessary to optimally display anatomy and fully characterize a lesion. Computerized calculations and simulations suggest that no other combination of pulse sequences yields equal information for a given examination time

  5. Fast spin-echo T2-weighted MR imaging of tongue cancer; the value of fat-suppression

    International Nuclear Information System (INIS)

    Kim, Zu Byoung; Na, Dong Gyu; Ryoo, Jae Wook; Kim, Kyeong Ah; Byun, Hong Sik; Baek, Chung Whan; Son, Yong Ik

    2000-01-01

    To compare the diagnostic efficacy of fast spin-echo (FSE) T2-weighted MR imaging with and without fat suppression. Twelve patients (7 men and 5 women; mean age, 48 years) with pathologically proven cancer of the tongue were included in this study. In all of these, FSE T2-weighted MR images with and without fat suppression were obtained in the same imaging planes before surgery or biopsy. Two radiologists visually compared the images thus obtained in terms of detection, extent, and conspicuity of the tumor, and the contrast-to-noise ratio (CNR) of each tumor was also calculated. In all patients, both imaging modalities were equal in terms of tumor detection. In 4 of 12(33%), the extent of the tumor was greater with fat suppression, while in eight (67%), it was almost the same both with and without. In ten patients (83%), the tumor was more conspicuous with fat suppression, and percentage CNRs were significantly higher with fat suppression than without (180±70% and 113±61%, respectively; p=0.02). For the evaluation of patients with tongue cancer, fat-suppressed FSE T2-weighted MR imaging is superior to its conventional equivalent

  6. Externally placed vs intravaginally positioned radio frequency coils for quantitative spin-spin relaxometry of ovarian follicular fluid

    International Nuclear Information System (INIS)

    Sarty, G.E.; Baerwald, A.R.; Loewy, J.; Pierson, R.A.

    2005-01-01

    To evaluate different imaging protocols, especially with respect to radio frequency (RF) receiver coil location, for Their suitability in providing least squares derived quantitative T 2 values of ovarian follicular fluid for investigations of basic ovarian physiology. Methods: The ovaries of 10 women were imaged via magnetic resonance imaging (MRI) using externally positioned and intravaginally placed RF receiver coils. Half-Fourier acquisition with single-shot turbo spin-echo (HASTE), multiple-echo T 2 , Dixon, turbo spin-echo, and 3-dimensional (3D) fast imaging with steady-state precession (FISP) and time-reversed FISP (PSIF) sequences were used. Quantitative T 2 nuclear spin relaxation rate information from the ovarian follicles between data acquired with the external and intravaginal coils were compared. Additionally, the amount of ovarian follicle and corpora lutea structural detail visible was qualitatively assessed. Results: The T 2 computations indicated that there was no difference in the follicular fluid T 2 values or in the heterogeneity (spatial variance) of the T 2 values between data acquired with the external RF coil and date acquired with the intravaginal RF coil. The best sequences for the visualization of ovarian internal structure were the 3D PSIF sequences and the multiple-echo T 2 -weighted images, confirming our earlier imaging work on excised cow ovaries. Conclusion: It is best to use an externally placed RF coil for quantitative MRI study of ovarian physiology given the lack of difference in quantitative T 2 information and the difficulty associated with imaging the ovaries using an intravaginal RF probe. (author)

  7. Revised PROPELLER for T2-weighted imaging of the prostate at 3 Tesla: impact on lesion detection and PI-RADS classification

    International Nuclear Information System (INIS)

    Meier-Schroers, Michael; Marx, Christian; Schmeel, Frederic Carsten; Wolter, Karsten; Block, Wolfgang; Sprinkart, Alois Martin; Traeber, Frank; Schild, Hans Heinz; Kukuk, Guido Matthias; Gieseke, Juergen; Willinek, Winfried

    2018-01-01

    To evaluate revised PROPELLER (RevPROP) for T2-weighted imaging (T2WI) of the prostate as a substitute for turbo spin echo (TSE). Three-Tesla MR images of 50 patients with 55 cancer-suspicious lesions were prospectively evaluated. Findings were correlated with histopathology after MRI-guided biopsy. T2 RevPROP, T2 TSE, diffusion-weighted imaging, dynamic contrast enhancement, and MR-spectroscopy were acquired. RevPROP was compared to TSE concerning PI-RADS scores, lesion size, lesion signal-intensity, lesion contrast, artefacts, and image quality. There were 41 carcinomas in 55 cancer-suspicious lesions. RevPROP detected 41 of 41 carcinomas (100%) and 54 of 55 lesions (98.2%). TSE detected 39 of 41 carcinomas (95.1%) and 51 of 55 lesions (92.7%). RevPROP showed fewer artefacts and higher image quality (each p < 0.001). No differences were observed between single and overall PI-RADS scores based on RevPROP or TSE (p = 0.106 and p = 0.107). Lesion size was not different (p = 0.105). T2-signal intensity of lesions was higher and T2-contrast of lesions was lower on RevPROP (each p < 0.001). For prostate cancer detection RevPROP is superior to TSE with respect to motion robustness, image quality and detection rates of lesions. Therefore, RevPROP might be used as a substitute for T2WI. (orig.)

  8. Revised PROPELLER for T2-weighted imaging of the prostate at 3 Tesla: impact on lesion detection and PI-RADS classification

    Energy Technology Data Exchange (ETDEWEB)

    Meier-Schroers, Michael; Marx, Christian; Schmeel, Frederic Carsten; Wolter, Karsten; Block, Wolfgang; Sprinkart, Alois Martin; Traeber, Frank; Schild, Hans Heinz; Kukuk, Guido Matthias [University Hospital Bonn, Department of Radiology, Bonn (Germany); Gieseke, Juergen [Philips Healthcare Germany, Hamburg (Germany); Willinek, Winfried [Hospital of Barmherzige Brueder, Department of Radiology, Neuroradiology, Sonography and Nuclear Medicine, Trier (Germany)

    2018-01-15

    To evaluate revised PROPELLER (RevPROP) for T2-weighted imaging (T2WI) of the prostate as a substitute for turbo spin echo (TSE). Three-Tesla MR images of 50 patients with 55 cancer-suspicious lesions were prospectively evaluated. Findings were correlated with histopathology after MRI-guided biopsy. T2 RevPROP, T2 TSE, diffusion-weighted imaging, dynamic contrast enhancement, and MR-spectroscopy were acquired. RevPROP was compared to TSE concerning PI-RADS scores, lesion size, lesion signal-intensity, lesion contrast, artefacts, and image quality. There were 41 carcinomas in 55 cancer-suspicious lesions. RevPROP detected 41 of 41 carcinomas (100%) and 54 of 55 lesions (98.2%). TSE detected 39 of 41 carcinomas (95.1%) and 51 of 55 lesions (92.7%). RevPROP showed fewer artefacts and higher image quality (each p < 0.001). No differences were observed between single and overall PI-RADS scores based on RevPROP or TSE (p = 0.106 and p = 0.107). Lesion size was not different (p = 0.105). T2-signal intensity of lesions was higher and T2-contrast of lesions was lower on RevPROP (each p < 0.001). For prostate cancer detection RevPROP is superior to TSE with respect to motion robustness, image quality and detection rates of lesions. Therefore, RevPROP might be used as a substitute for T2WI. (orig.)

  9. Evaluation of endometrial carcinoma by multislice dynamic MR imaging with Turbo FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Asakawa, Mari [Okayama Univ. (Japan). School of Medicine

    1995-04-01

    The purpose of this study was to investigate the usefulness of multislice dynamic MR imaging with Turbo FLASH in assessing myometrial invasion by endometrial carcinoma. Dynamic MR imaging was performed with bolus injection of Gd-DTPA and with 1.5-T Siemens Magnetom imager using Turbo FLASH. Thirty-six endometrial carcinomas were evaluated with pathologic correlation. Junctional zone showed more rapid contrast enhancement effects than myometrium even after menopause. Contrast to noise ratio between junctional zone and endometrial carcinoma was the highest about fifty seconds after bolus injection. Only at that time could the degree of invasion to junctional zone in post-menopausal women whose junctional zones could not be seen on T{sub 2}-weighted images or contrast-enhanced T{sub 1}-weighted images be evaluated correctly. The accuracy in assessing myometrial invasion with T{sub 2}-weighted images, postcontrast T{sub 1}-weighted images, and dynamic MR imaging was 75%, 81% and 89% respectively. Though there was no statistically significant difference, multislice dynamic imaging with Turbo FLASH technique is considered to be a useful imaging method for the pre-operative assessment of myometrial invasion by endometrial carcinoma. (author).

  10. Comparison of two-dimensional fast spin echo T2 weighted sequences and three-dimensional volume isotropic T2 weighted fast spin echo (VISTA) MRI in the evaluation of triangular fibrocartilage of the wrist.

    Science.gov (United States)

    Park, Hee Jin; Lee, So Yeon; Kang, Kyung A; Kim, Eun Young; Shin, Hun Kyu; Park, Se Jin; Park, Jai Hyung; Kim, Eugene

    2018-04-01

    To compare image quality of three-dimensional volume isotropic T 2 weighted fast spin echo (3D VISTA) and two-dimensional (2D) T 2 weighted images (T2WI) for evaluation of triangular fibrocartilage (TFC) and to investigate whether 3D VISTA can replace 2D T 2 WI in evaluating TFC injury. This retrospective study included 69 patients who received wrist MRIs using both 2D T 2 WI and 3D VISTA techniques for assessment of wrist pathology, including TFC injury. Two radiologists measured the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) of the two sequences. The anatomical identification score and diagnostic performance were independently assessed by two interpreters. The diagnostic abilities of 3D VISTA and 2D T 2 WI were analysed by sensitivity, specificity and accuracy for diagnosing TFC injury using surgically or clinically confirmed diagnostic reference standards. 17 cases (25%) were classified as having TFC injury. 2 cases (12%) were diagnosed surgically, and 15 cases (88%) were diagnosed by physical examination. 52 cases (75%) were diagnosed as having intact TFC. 8 of these cases (15%) were surgically confirmed, while the others were diagnosed by physical examination and clinical findings. The 3D VISTA images had significantly higher SNR and CNR values for the TFC than 2D T 2 WI images. The scores of 3D VISTA's total length, full width and sharpness were similar to those of 2D T 2 WI. We were unable to find a significant difference between 3D VISTA and 2D T 2 WI in the ability to diagnose TFC injury. 3D VISTA image quality is similar to that of 2D T 2 WI for TFC evaluation and is also excellent for tissue contrast. 3D VISTA can replace 2D images in TFC injury assessment. Advances in knowledge: 3D VISTA image quality is similar to that of 2D T 2 WI for TFC evaluation and is also excellent for tissue contrast. 3D VISTA can replace 2D images in TFC injury assessment.

  11. Quantitative evaluation of benign and malignant vertebral fractures with diffusion-weighted MRI: what is the optimum combination of b values for ADC-based lesion differentiation with the single-shot turbo spin-echo sequence?

    Science.gov (United States)

    Geith, Tobias; Schmidt, Gerwin; Biffar, Andreas; Dietrich, Olaf; Duerr, Hans Roland; Reiser, Maximilian; Baur-Melnyk, Andrea

    2014-09-01

    The purpose of our study was to determine the optimum combination of b values for calculating the apparent diffusion coefficient (ADC) using a diffusion-weighted (DW) single-shot turbo spin-echo (TSE) sequence in the differentiation between acute benign and malignant vertebral body fractures. Twenty-six patients with osteoporotic (mean age, 69 years; range, 31.5-86.2 years) and 20 patients with malignant vertebral fractures (mean age, 63.4 years; range, 24.7-86.4 years) were studied. T1-weighted, STIR, and T2-weighted sequences were acquired at 1.5 T. A DW single-shot TSE sequence at different b values (100, 250, 400, and 600 s/mm(2)) was applied. On the DW images for each evaluated fracture, an ROI was manually adapted to the area of hyperintense signal intensity on STIR-hypointense signal on T1-weighted images. For each ROI, nine different combinations of two, three, and four b values were used to calculate the ADC using a least-squares algorithm. The Student t test and Mann-Whitney U test were used to determine significant differences between benign and malignant fractures. An ROC analysis and the Youden index were used to determine cutoff values for assessment of the highest sensitivity and specificity for the different ADC values. The positive (PPV) and negative predictive values (NPV) were also determined. All calculated ADCs (except the combination of b = 400 s/mm(2) and b = 600 s/mm(2)) showed statistically significant differences between benign and malignant vertebral body fractures, with benign fractures having higher ADCs than malignant ones. The use of higher b values resulted in lower ADCs than those calculated with low b values. The highest AUC (0.85) showed the ADCs calculated with b = 100 and 400 s/mm(2), and the second highest AUC (0.829) showed the ADCs calculated with b = 100, 250, and 400 s/mm(2). The Youden index with equal weight given to sensitivity and specificity suggests use of an ADC calculated with b = 100, 250, and 400 s/mm(2) (cutoff

  12. Driven equilibrium (drive) MR imaging of the cranial nerves V-VIII: comparison with the T2-weighted 3D TSE sequence

    Energy Technology Data Exchange (ETDEWEB)

    Ciftci, E. E-mail: eciftcis7@hotmail.com; Anik, Yonca; Arslan, Arzu; Akansel, Gur; Sarisoy, Tahsin; Demirci, Ali

    2004-09-01

    Purpose: The aim of this study is to evaluate the efficacy of the driven equilibrium radio frequency reset pulse (DRIVE) on image quality and nerve detection when used in adjunction with T2-weighted 3D turbo spin-echo (TSE) sequence. Materials and methods: Forty-five patients with cranial nerve symptoms referable to the cerebellopontine angle (CPA) were examined using a T2-weighted 3D TSE pulse sequence with and without DRIVE. MR imaging was performed on a 1.5-T MRI scanner. In addition to the axial resource images, reformatted oblique sagittal, oblique coronal and maximum intensity projection (MIP) images of the inner ear were evaluated. The nerve identification and image quality were graded for the cranial nerves V-VIII as well as inner ear structures. These structures were chosen because fluid-solid interfaces existed due to the CSF around (the cranial nerves V-VIII) or the endolymph within (the inner ear structures). Statistical analysis was performed using the Wilcoxon test. P<0.05 was considered significant. Results: The addition of the DRIVE pulse shortens the scan time by 25%. T2-weighted 3D TSE sequence with DRIVE performed slightly better than the T2-weighted 3D TSE sequence without DRIVE in identifying the individual nerves. The image quality was also slightly better with DRIVE. Conclusion: The addition of the DRIVE pulse to the T2-weighted 3D TSE sequence is preferable when imaging the cranial nerves surrounded by the CSF, or fluid-filled structures because of shorter scan time and better image quality due to reduced flow artifacts.

  13. Driven equilibrium (drive) MR imaging of the cranial nerves V-VIII: comparison with the T2-weighted 3D TSE sequence

    International Nuclear Information System (INIS)

    Ciftci, E.; Anik, Yonca; Arslan, Arzu; Akansel, Gur; Sarisoy, Tahsin; Demirci, Ali

    2004-01-01

    Purpose: The aim of this study is to evaluate the efficacy of the driven equilibrium radio frequency reset pulse (DRIVE) on image quality and nerve detection when used in adjunction with T2-weighted 3D turbo spin-echo (TSE) sequence. Materials and methods: Forty-five patients with cranial nerve symptoms referable to the cerebellopontine angle (CPA) were examined using a T2-weighted 3D TSE pulse sequence with and without DRIVE. MR imaging was performed on a 1.5-T MRI scanner. In addition to the axial resource images, reformatted oblique sagittal, oblique coronal and maximum intensity projection (MIP) images of the inner ear were evaluated. The nerve identification and image quality were graded for the cranial nerves V-VIII as well as inner ear structures. These structures were chosen because fluid-solid interfaces existed due to the CSF around (the cranial nerves V-VIII) or the endolymph within (the inner ear structures). Statistical analysis was performed using the Wilcoxon test. P<0.05 was considered significant. Results: The addition of the DRIVE pulse shortens the scan time by 25%. T2-weighted 3D TSE sequence with DRIVE performed slightly better than the T2-weighted 3D TSE sequence without DRIVE in identifying the individual nerves. The image quality was also slightly better with DRIVE. Conclusion: The addition of the DRIVE pulse to the T2-weighted 3D TSE sequence is preferable when imaging the cranial nerves surrounded by the CSF, or fluid-filled structures because of shorter scan time and better image quality due to reduced flow artifacts

  14. Volumetric fat-water separated T2-weighted MRI

    International Nuclear Information System (INIS)

    Vasanawala, Shreyas S.; Sonik, Arvind; Madhuranthakam, Ananth J.; Venkatesan, Ramesh; Lai, Peng; Brau, Anja C.S.

    2011-01-01

    Pediatric body MRI exams often cover multiple body parts, making the development of broadly applicable protocols and obtaining uniform fat suppression a challenge. Volumetric T2 imaging with Dixon-type fat-water separation might address this challenge, but it is a lengthy process. We develop and evaluate a faster two-echo approach to volumetric T2 imaging with fat-water separation. A volumetric spin-echo sequence was modified to include a second shifted echo so two image sets are acquired. A region-growing reconstruction approach was developed to decompose separate water and fat images. Twenty-six children were recruited with IRB approval and informed consent. Fat-suppression quality was graded by two pediatric radiologists and compared against conventional fat-suppressed fast spin-echo T2-W images. Additionally, the value of in- and opposed-phase images was evaluated. Fat suppression on volumetric images had high quality in 96% of cases (95% confidence interval of 80-100%) and were preferred over or considered equivalent to conventional two-dimensional fat-suppressed FSE T2 imaging in 96% of cases (95% confidence interval of 78-100%). In- and opposed-phase images had definite value in 12% of cases. Volumetric fat-water separated T2-weighted MRI is feasible and is likely to yield improved fat suppression over conventional fat-suppressed T2-weighted imaging. (orig.)

  15. Simultaneous Measurement of T2 and Apparent Diffusion Coefficient (T2+ADC) in the Heart With Motion-Compensated Spin Echo Diffusion-Weighted Imaging

    Science.gov (United States)

    Aliotta, Eric; Moulin, Kévin; Zhang, Zhaohuan; Ennis, Daniel B.

    2018-01-01

    Purpose To evaluate a technique for simultaneous quantitative T2 and apparent diffusion coefficient (ADC) mapping in the heart (T2+ADC) using spin echo (SE) diffusion-weighted imaging (DWI). Theory and Methods T2 maps from T2+ADC were compared with single-echo SE in phantoms and with T2-prepared (T2-prep) balanced steady-state free precession (bSSFP) in healthy volunteers. ADC maps from T2+ADC were compared with conventional DWI in phantoms and in vivo. T2+ADC was also demonstrated in a patient with acute myocardial infarction (MI). Results Phantom T2 values from T2+ADC were closer to a single-echo SE reference than T2-prep bSSFP (−2.3 ± 6.0% vs 22.2 ± 16.3%; P T2 values from T2+ADC were significantly shorter than T2-prep bSSFP (35.8 ± 3.1 vs 46.8 ± 3.8 ms; P T2+ADC and conventional motion-compensated DWI (1.39 ± 0.18 vs 1.38 ± 0.18 mm2/ms; P = N.S.). In the patient, T2 and ADC were both significantly elevated in the infarct compared with remote myocardium (T2: 40.4 ± 7.6 vs 56.8 ± 22.0; P T2+ADC generated coregistered, free-breathing T2 and ADC maps in healthy volunteers and a patient with acute MI with no cost in accuracy, precision, or scan time compared with DWI. PMID:28516485

  16. MR Imaging of the Spine at 3.0T with T2-Weighted IDEAL Fast Recovery Fast Spin-Echo Technique

    International Nuclear Information System (INIS)

    Ren, Ai Jun; Guo, Yong; Tian, Shu Ping; Shi, Li Jing; Huang, Min Hua

    2012-01-01

    To compare the iterative decomposition of water and fat with echo asymmetry and the least-squares estimation (IDEAL) method with a fat-saturated T2-weighted (T2W) fast recovery fast spin-echo (FRFSE) imaging of the spine. Images acquired at 3.0 Tesla (T) in 35 patients with different spine lesions using fat-saturated T2W FRFSE imaging were compared with T2W IDEAL FRFSE images. Signal-to-noise ratio (SNR)-efficiencies measurements were made in the vertebral bodies and spinal cord in the mid-sagittal plane or nearest to the mid-sagittal plane. Images were scored with the consensus of two experienced radiologists on a four-point grading scale for fat suppression and overall image quality. Statistical analysis of SNR-efficiency, fat suppression and image quality scores was performed with a paired Student's t test and Wilcoxon's signed rank test. Signal-to-noise ratio-efficiency for both vertebral body and spinal cord was higher with T2W IDEAL FRFSE imaging (p < 0.05) than with T2W FRFSE imaging. T2W IDEAL FRFSE demonstrated superior fat suppression (p < 0.01) and image quality (p < 0.01) compared to fat-saturated T2W FRFSE. As compared with fat-saturated T2W FRFSE, IDEAL can provide a higher image quality, higher SNR-efficiency, and consistent, robust and uniform fat suppression. T2W IDEAL FRFSE is a promising technique for MR imaging of the spine at 3.0T.

  17. Moderately T2-weighted images obtained with the single-shot fast spin-echo technique. Differentiating between malignant and benign urinary obstructions

    International Nuclear Information System (INIS)

    Obuchi, Masao; Sugimoto, Hideharu; Kubota, Hayato; Yamamoto, Wakako; Kinebuchi, Yuko; Honda, Minoru; Takahara, Taro

    2002-01-01

    The purpose of this study was to determine whether a distinction could be made between benign and malignant urinary obstructions in moderately T 2 -weighted images obtained with the single-shot fast spin-echo technique. Forty-four lesions in 39 patients with urinary obstruction were evaluated with the single-shot fast spin-echo (SSFSE) technique with an effective TE of 90-100 ms and without fat saturation. Benign and malignant lesions were compared for the presence of ureteral wall thickening and a signal intensity relative to the proximal ureteral wall. Statistically significant differences were found between benign and malignant lesions in both morphologic change (P 2 -weighted SSFSE technique without fat saturation can accurately distinguish between benign and malignant urinary obstructions. (author)

  18. Peripheral nerve MRI: precision and reproducibility of T2*-derived measurements at 3.0-T. A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Tagliafico, Alberto [University of Genoa, Institute of Anatomy, Department of Experimental Medicine, Genoa (Italy); Bignotti, Bianca; Martinoli, Carlo [University of Genoa, Radiology Department, Genoa, Genova (Italy); Tagliafico, Giulio [CNR-IMATI, Consiglio Nazionale delle Ricerche, Istituto di Matematica Applicata e Tecnologie Informatiche, Genova (Italy)

    2015-05-01

    To prospectively evaluate the precision and reproducibility of T2*-derived measurements of the peripheral nerves. The study was approved by the local ethics committee and written informed consent was obtained. Bilateral upper and lower limb MRI examination was performed in 40 healthy subjects on a 3.0-T scanner. MRI protocol included T1-turbo spin-echo, T2-turbo spin-echo with fat suppression, and multiecho gradient recalled echo. Measurements of T2* times on T2* maps at different anatomical levels were performed. Three authors measured independently and in different sessions at baseline and after 4 weeks. Non-parametric tests and Bland-Altman statistics were used. Minimum and maximum percentage variability were 10 % and 19 % for T2* (84-91 % of reproducibility). Maximum values of minimum detectable differences between limbs was 16 % (with 95 % CI: 2-37). Intra- and inter-observer agreement of the three radiologists for T2* was considered good. Evaluating the combined influence of the observer and of the repeated measurements the reproducibility was 87-98 %. T2* measurement of the peripheral nerves is precise and reproducible. The healthy contralateral side can be used as an internal control. Variations in T2* values up to 16 % have to be considered. (orig.)

  19. Optimal control design of turbo spin-echo sequences with applications to parallel-transmit systems

    NARCIS (Netherlands)

    Sbrizzi, Alessandro; Hoogduin, Hans; Hajnal, Joseph V; van den Berg, CAT; Luijten, Peter R; Malik, Shaihan J

    PURPOSE: The design of turbo spin-echo sequences is modeled as a dynamic optimization problem which includes the case of inhomogeneous transmit radiofrequency fields. This problem is efficiently solved by optimal control techniques making it possible to design patient-specific sequences online.

  20. Supraspinatus tendon tears at 3.0 T shoulder MR arthrography: diagnosis with 3D isotropic turbo spin-echo SPACE sequence versus 2D conventional sequences

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Joon-Yong; Jee, Won-Hee; Park, Michael Y.; Lee, So-Yeon [Seoul St. Mary' s Hospital, The Catholic University of Korea, Department of Radiology, Seoul (Korea, Republic of); Kim, Yang-Soo [Seoul St. Mary' s Hospital, The Catholic University of Korea, Department of Orthopedic Surgery, Seoul (Korea, Republic of)

    2012-11-15

    To assess the diagnostic performance of shoulder MR arthrography with 3D isotropic fat-suppressed (FS) turbo spin-echo sequence (TSE-SPACE) for supraspinatus tendon tears in comparison with 2D conventional sequences at 3.0 T. The study was HIPAA-compliant and approved by the institutional review board with a waiver of informed consent. Eighty-seven arthroscopically confirmed patients who underwent 3.0 T shoulder MR arthrography with 2D sequences and 3D TSE-SPACE were included in a consecutive fashion from March 2009 to February 2010. Two reviewers independently analyzed 2D sequences and 3D TSE-SPACE. Sensitivity, specificity, accuracy, and interobserver agreement ({kappa}) were compared between 2D sequences and 3D TSE-SPACE for full-thickness and partial-thickness supraspinatus tendon tears together and for partial-thickness supraspinatus tendon tears alone. There were 33 full-thickness tears and 28 partial-thickness tears of supraspinatus tendons. For full-thickness and partial-thickness supraspinatus tendon tears together, the mean sensitivity, specificity, and accuracy of both readers were 96, 92, and 94% on 2D sequences and 91, 84, and 89% on 3D TSE-SPACE. For partial-thickness supraspinatus tendon tears alone, the mean sensitivity, specificity, and accuracy were 95, 92, and 94% on 2D sequences and 84, 85, and 84% on 3D TSE-SPACE. There was no statistical difference between 2D sequences and 3D TSE-SPACE. Interobserver agreements were almost perfect on 2D conventional sequences and substantial on 3D TSE-SPACE. Compared with 2D conventional sequences, MR arthrography using 3D TSE-SPACE was comparable for diagnosing supraspinatus tendon tears despite limitations in detecting small partial-thickness tears and in discriminating between full-thickness and deep partial-thickness tears. (orig.)

  1. Supraspinatus tendon tears at 3.0 T shoulder MR arthrography: diagnosis with 3D isotropic turbo spin-echo SPACE sequence versus 2D conventional sequences

    International Nuclear Information System (INIS)

    Jung, Joon-Yong; Jee, Won-Hee; Park, Michael Y.; Lee, So-Yeon; Kim, Yang-Soo

    2012-01-01

    To assess the diagnostic performance of shoulder MR arthrography with 3D isotropic fat-suppressed (FS) turbo spin-echo sequence (TSE-SPACE) for supraspinatus tendon tears in comparison with 2D conventional sequences at 3.0 T. The study was HIPAA-compliant and approved by the institutional review board with a waiver of informed consent. Eighty-seven arthroscopically confirmed patients who underwent 3.0 T shoulder MR arthrography with 2D sequences and 3D TSE-SPACE were included in a consecutive fashion from March 2009 to February 2010. Two reviewers independently analyzed 2D sequences and 3D TSE-SPACE. Sensitivity, specificity, accuracy, and interobserver agreement (κ) were compared between 2D sequences and 3D TSE-SPACE for full-thickness and partial-thickness supraspinatus tendon tears together and for partial-thickness supraspinatus tendon tears alone. There were 33 full-thickness tears and 28 partial-thickness tears of supraspinatus tendons. For full-thickness and partial-thickness supraspinatus tendon tears together, the mean sensitivity, specificity, and accuracy of both readers were 96, 92, and 94% on 2D sequences and 91, 84, and 89% on 3D TSE-SPACE. For partial-thickness supraspinatus tendon tears alone, the mean sensitivity, specificity, and accuracy were 95, 92, and 94% on 2D sequences and 84, 85, and 84% on 3D TSE-SPACE. There was no statistical difference between 2D sequences and 3D TSE-SPACE. Interobserver agreements were almost perfect on 2D conventional sequences and substantial on 3D TSE-SPACE. Compared with 2D conventional sequences, MR arthrography using 3D TSE-SPACE was comparable for diagnosing supraspinatus tendon tears despite limitations in detecting small partial-thickness tears and in discriminating between full-thickness and deep partial-thickness tears. (orig.)

  2. What is the most suitable MR signal index for quantitative evaluation of placental function using Half-Fourier acquisition single-shot turbo spin-echo compared with T2-relaxation time?

    Science.gov (United States)

    Kameyama, Kyoko Nakao; Kido, Aki; Himoto, Yuki; Moribata, Yusaku; Minamiguchi, Sachiko; Konishi, Ikuo; Togashi, Kaori

    2018-06-01

    Background Half-Fourier acquisition single-shot turbo spin-echo (HASTE) imaging is now widely used for placental and fetal imaging because of its rapidity and low sensitivity to fetal movement. If placental dysfunction is also predicted by quantitative value obtained from HASTE image, then it might be beneficial for evaluating placental wellbeing. Purpose To ascertain the most suitable magnetic resonance (MR) signal indexes reflecting placental function using HASTE imaging. Material and Methods This retrospective study included 37 consequent patients who had given informed consent to MR imaging (MRI) examinations. All had undergone MRI examinations between February 2014 and June 2015. First, the correlation between T2-relaxation time of normal placenta and gestational age (GA) was examined. Second, correlation between signal intensity ratios (SIRs) using HASTE imaging and placental T2-relaxation time were assessed. The SIRs were calculated using placental signal intensity (SI) relative to the SI of the amniotic fluid, fetal ocular globes, gastric fluid, bladder, maternal psoas major muscles, and abdominal subcutaneous adipose tissue. Results Among the 37 patients, the correlation between T2-relaxation time of the 25 normal placentas and GA showed a moderately strong correlation (Spearman rho = -0.447, P = 0.0250). The most significant correlation with placental T2-relaxation time was observed with the placental SIR relative to the maternal psoas major muscles (SIR pl./psoas muscle ) (Spearman rho = -0.531, P = 0.0007). Conclusion This study revealed that SIR pl./psoas muscle showed the best correlation to placental T2-relaxation time. Results show that SIR pl./psoas muscle might be optimal as a clinically available quantitative index of placental function.

  3. T2-weighted fast spin-echo MR imaging of the pelvis

    International Nuclear Information System (INIS)

    Francis, I.R.; Steiner, R.M.; Herfkens, R.J.; Jain, K.; Glover, G.H.

    1991-01-01

    A fast Se (FSE) sequence capable of acquiring SE images with a wide range of TRs and TEs in short imaging times has been recently introduced. I this paper, the authors evaluated the value of this technique compared with standard T2-weighted SE imaging. Twenty-five patients were evaluated with T2-weighted SE and FSE images on a 1.5-T GE Signa imager. Imaging times ranged from 3 to 5 minutes for the FSE acquisition and from 12 to 15 minutes for the SE images. Three observers performed a comparison by using a 10-point scale for organ definition and lesion conspicuity, with differences settled by consensus reading. Pelvic organ definition was superior and pelvic tumors and free fluid were also more conspicuous on FSE images. In 2/25 patients ringing artifacts were present

  4. Geometrically undistorted MRI in the presence of field inhomogeneities using compressed sensing accelerated broadband 3D phase encoded turbo spin-echo imaging

    International Nuclear Information System (INIS)

    Van Gorp, Jetse S; Bakker, Chris J G; Bouwman, Job G; Zijlstra, Frank; Seevinck, Peter R; Smink, Jouke

    2015-01-01

    In this study, we explore the potential of compressed sensing (CS) accelerated broadband 3D phase-encoded turbo spin-echo (3D-PE-TSE) for the purpose of geometrically undistorted imaging in the presence of field inhomogeneities. To achieve this goal 3D-PE-SE and 3D-PE-TSE sequences with broadband rf pulses and dedicated undersampling patterns were implemented on a clinical scanner. Additionally, a 3D multi-spectral spin-echo (ms3D-SE) sequence was implemented for reference purposes. First, we demonstrated the influence of susceptibility induced off-resonance effects on the spatial encoding of broadband 3D-SE, ms3D-SE, 3D-PE-SE and 3D-PE-TSE using a grid phantom containing a titanium implant (Δχ = 182 ppm) with x-ray CT as a gold standard. These experiments showed that the spatial encoding of 3D-PE-(T)SE was unaffected by susceptibility induced off-resonance effects, which caused geometrical distortions and/or signal hyper-intensities in broadband 3D-SE and, to a lesser extent, in ms3D-SE frequency encoded methods. Additionally, an SNR analysis was performed and the temporally resolved signal of 3D-PE-(T)SE sequences was exploited to retrospectively decrease the acquisition bandwidth and obtain field offset maps. The feasibility of CS acceleration was studied retrospectively and prospectively for the 3D-PE-SE sequence using an existing CS algorithm adapted for the reconstruction of 3D data with undersampling in all three phase encoded dimensions. CS was combined with turbo-acceleration by variable density undersampling and spherical stepwise T 2 weighting by randomly sorting consecutive echoes in predefined spherical k-space layers. The CS-TSE combination resulted in an overall acceleration factor of 60, decreasing the original 3D-PE-SE scan time from 7 h to 7 min. Finally, CS accelerated 3D-PE-TSE in vivo images of a titanium screw were obtained within 10 min using a micro-coil demonstrating the feasibility of geometrically undistorted MRI near severe

  5. Effectiveness of a Rapid Lumbar Spine MRI Protocol Using 3D T2-Weighted SPACE Imaging Versus a Standard Protocol for Evaluation of Degenerative Changes of the Lumbar Spine.

    Science.gov (United States)

    Sayah, Anousheh; Jay, Ann K; Toaff, Jacob S; Makariou, Erini V; Berkowitz, Frank

    2016-09-01

    Reducing lumbar spine MRI scanning time while retaining diagnostic accuracy can benefit patients and reduce health care costs. This study compares the effectiveness of a rapid lumbar MRI protocol using 3D T2-weighted sampling perfection with application-optimized contrast with different flip-angle evolutions (SPACE) sequences with a standard MRI protocol for evaluation of lumbar spondylosis. Two hundred fifty consecutive unenhanced lumbar MRI examinations performed at 1.5 T were retrospectively reviewed. Full, rapid, and complete versions of each examination were interpreted for spondylotic changes at each lumbar level, including herniations and neural compromise. The full examination consisted of sagittal T1-weighted, T2-weighted turbo spin-echo (TSE), and STIR sequences; and axial T1- and T2-weighted TSE sequences (time, 18 minutes 40 seconds). The rapid examination consisted of sagittal T1- and T2-weighted SPACE sequences, with axial SPACE reformations (time, 8 minutes 46 seconds). The complete examination consisted of the full examination plus the T2-weighted SPACE sequence. Sensitivities and specificities of the full and rapid examinations were calculated using the complete study as the reference standard. The rapid and full studies had sensitivities of 76.0% and 69.3%, with specificities of 97.2% and 97.9%, respectively, for all degenerative processes. Rapid and full sensitivities were 68.7% and 66.3% for disk herniation, 85.2% and 81.5% for canal compromise, 82.9% and 69.1% for lateral recess compromise, and 76.9% and 69.7% for foraminal compromise, respectively. Isotropic SPACE T2-weighted imaging provides high-quality imaging of lumbar spondylosis, with multiplanar reformatting capability. Our SPACE-based rapid protocol had sensitivities and specificities for herniations and neural compromise comparable to those of the protocol without SPACE. This protocol fits within a 15-minute slot, potentially reducing costs and discomfort for a large subgroup of

  6. Application of three-dimensional fast spin-echo T2-weighted image in lesions of the inner ear

    International Nuclear Information System (INIS)

    Xian Junfang; Wang Zhenchang; Yan Fei; Niu Yantao; Zhu Ye; Wang Yan; Tian Qichang; Lan Baosen

    1999-01-01

    Objective: To investigate the advantage of three-dimensional fast spin-echo T 2 -weighted image (3D FSE T 2 WI) in depicting normal structures and lesions of the inner ear. Methods: 3D FSE T 2 WI and 2D FSE T 2 WI were performed in 10 healthy volunteers and 20 cases with inner ear diseases. Advantages and disadvantages of the two techniques were compared. CT was performed in 6 cases with enlarged endo-lymphatic sac and 1 cases of Mondini malformation. Results: 3D FSE T 2 WI enabled visualization of detailed anatomic structures. Enlarged endo-lymphatic sacs were clearly revealed in 9 cases on 16 sides by 3D FSE T 2 WI, while only a part but not the whole of the enlarged endo-lymphatic sac could be shown on 2D FSE T 2 WI. In 6 cases, 3D FSE T 2 WI displayed enlarged endo-lymphatic sac on 11 sides and normal on 1 side; however, CT revealed enlarged vestibular aqueduct on all 12 sides. One case with small acoustic neuroma (only 4 mm in diameter) was clearly demonstrated on 3D FSE T 2 WI but not well shown on 2D FSE T 2 WI. One case with cochlear Mondini malformation associated with dysplasia of vestibule and semicircular canals was displayed more clearly on 3D FSE T 2 WI than on 2D FSE T 2 WI. Conclusions: 3D FSE T 2 WI can clearly display normal structures and lesions of the inner ear

  7. SU-E-J-157: Improving the Quality of T2-Weighted 4D Magnetic Resonance Imaging for Clinical Evaluation

    International Nuclear Information System (INIS)

    Du, D; Mutic, S; Hu, Y; Caruthers, S; Glide-Hurst, C; Low, D

    2014-01-01

    Purpose: To develop an imaging technique that enables us to acquire T2- weighted 4D Magnetic Resonance Imaging (4DMRI) with sufficient spatial coverage, temporal resolution and spatial resolution for clinical evaluation. Methods: T2-weighed 4DMRI images were acquired from a healthy volunteer using a respiratory amplitude triggered T2-weighted Turbo Spin Echo sequence. 10 respiratory states were used to equally sample the respiratory range based on amplitude (0%, 20%i, 40%i, 60%i, 80%i, 100%, 80%e, 60%e, 40%e and 20%e). To avoid frequent scanning halts, a methodology was devised that split 10 respiratory states into two packages in an interleaved manner and packages were acquired separately. Sixty 3mm sagittal slices at 1.5mm in-plane spatial resolution were acquired to offer good spatial coverage and reasonable spatial resolution. The in-plane field of view was 375mm × 260mm with nominal scan time of 3 minutes 42 seconds. Acquired 2D images at the same respiratory state were combined to form the 3D image set corresponding to that respiratory state and reconstructed in the coronal view to evaluate whether all slices were at the same respiratory state. 3D image sets of 10 respiratory states represented a complete 4D MRI image set. Results: T2-weighted 4DMRI image were acquired in 10 minutes which was within clinical acceptable range. Qualitatively, the acquired MRI images had good image quality for delineation purposes. There were no abrupt position changes in reconstructed coronal images which confirmed that all sagittal slices were in the same respiratory state. Conclusion: We demonstrated it was feasible to acquire T2-weighted 4DMRI image set within a practical amount of time (10 minutes) that had good temporal resolution (10 respiratory states), spatial resolution (1.5mm × 1.5mm × 3.0mm) and spatial coverage (60 slices) for future clinical evaluation

  8. The evaluation of fat saturation fast spin-echo T2W1 for patients with acute spinal trauma

    International Nuclear Information System (INIS)

    Kim, Sung Gyu; Lee, Chang Jun; Lee, Myung Joon; Kang, Ik Won; Yoo, Jeong Hyun

    2002-01-01

    To determine the usefulness of fat saturation fast spin-echo T2W1 for patients with mild acute trauma of the spine. Between July 1998 and June 2002, 36 patients with acute spinal trauma underwent MRI within four months of injury. One, whose clinal symptoms indicated neurological paralysis, was excluded form our study. A superconductive 1.0-T MRI scanner was used, and conventional T1W1, T2W1, and additional fat-saturation fast spin-echo T2W1 were performed. Two radiologists compared conventional T2-weighted sagittal imaging and fat-saturation T2-weighted sagittal imaging in terms of the extension of increased high signal intensities in soft tissue and vertebral bodies, bone marrow signal change, disk herniation, and signal change of the disk. The detection rate of focal high signal intensities in soft tissue and bone marrow was significantly higher at fat-saturation fast spin-echo T2W1 than at conventional T2W1. Fat-saturation fast spin-echo T2W1 is useful for the evaluation of patients with mild acute spinal trauma without neurological impairment

  9. The evaluation of fat saturation fast spin-echo T2WI for patients with acute spinal trauma

    International Nuclear Information System (INIS)

    Kim, Sung Gyu; Lee, Chang Jun; Lee, Myung Joon; Kang, Ik Won; Yoo, Jeong Hyun

    2002-01-01

    To determine the usefulness of fat saturation fast spin-echo T2WI for patients with mild acute trauma of the spine. Between July 1998 and June 2002, 36 patients with acute spinal trauma underwent MRI within four months of injury. One, whose clinal symptoms indicated neurological paralysis, was excluded form our study. A superconductive 1.0-T MRI scanner was used, and conventional T1W1, T2W1, and additional fat-saturation fast spin-echo T2W1 were performed. Two radiologists compared conventional T2-weighted sagittal imaging and fat-saturation T2-weighted sagittal imaging in terms of the extension of increased high signal intensities in soft tissue and vertebral bodies, bone marrow signal change, disk herniation, and signal change of the disk. The detection rate of focal high signal intensities in soft tissue and bone marrow was significantly higher at fat-saturation fast spin-echo T2W1 is useful the evaluation of patients with mild acute spinal trauma without neurological impairment

  10. MRI of acute cerebral infarction: a comparison of FLAIR and T2-weighted fast spin-echo imaging

    International Nuclear Information System (INIS)

    Noguchi, K.; Ogawa, T.; Inugami, A.; Fujita, H.; Hatazawa, J.; Shimosegawa, E.; Okudera, T.; Uemura, K.; Seto, H.

    1997-01-01

    Fluid-attenuated inversion-recovery (FLAIR) sequences have been reported to provide high sensitivity to a wide range of central nervous system diseases. To our knowledge, however, FLAIR sequences have not been used to study patients with acute cerebral infarcts. We evaluated the usefulness of FLAIR sequences in this context. FLAIR sequences were acquired on a 0.5 T superconducting unit within 8 h of the onset in 19 patients (aged 26-80 years) with a total of 23 ischaemic lesions. The images were reviewed retrospectively by three neuroradiologists, and the FLAIR images were compared with T2-weighted fast spin-echo images. All but one of the ischaemic lesions involving grey matter was clearly demonstrated on FLAIR images as increased signal intensity in cortical or central grey matter. FLAIR images were particularly useful for detecting the hyperacute cortical infarcts within 3 h of onset, which were not readily detected on the spin-echo images. In 9 of 11 patients with complete proximal occlusion, the distal portion of the cerebral artery was visible as an area of high signal intensity on FLAIR images. (orig.). With 4 figs., 1 tab

  11. Clinical utility of partial flip angle T2-weighted spin-echo imaging of the brain

    International Nuclear Information System (INIS)

    Chang, K.H.; Yi, J.G.; Han, M.H.; Han, M.C.; Kim, C.W.; Cho, M.H.; Cho, Z.H.

    1990-01-01

    To assess the clinical usefulness of partial flip angle (PFA) spin-echo (SE) brain imaging, a total of eighty patients were examined with both conventional double echo T2-weighted SE (2500/30, 80/90deg/one excitation) and PFA double echo SE (1200/30, 70/45deg/two excitations) on 2.0T system. Two comparative studies were performed: (1) In 65 patients PFA SE technique was compared with conventional SE without flow compensating gradients, and (2) in 15 patients the former was compared with the latter with flow compensating gradients. Imaging time was nearly identical in each sequence. In both studies we found that PFA T2-weighted SE images were almost identical to those obtained with the conventional SE technique in the contrast characteristics and the detection rate of the abnormalities (100%, 85/85 lesions), and more importantly, PFA SE revealed few flow artifacts in the brain stem, temporal lobes and basal ganglia which were frequently seen on conventional SE without flow compensating gradients. Additionally, PFA SE images demonstrated no suppression of CSF flow void in the aqueduct which was commonly seen on conventional SE with flow compensating gradients. In overall image quality, the PFA SE images, particularly the second echo images, were almost comparable with those of conventional SE with flow compensating gradients. A flip angle of 45deg seems to be close to Ernst angle, the angle at which maximum signal occurs, for a given TR of 1200 msec for CSF and most of the abnormalities containing higher water content. In conclusion, PFA SE sequence (i.e. 1200/30, 70/45deg/2) appears to be useful as a primary or an adjunctive technique in certain clinical circumstances, particularly in imaging of hydrocephalic patients for assessing aqueductal patency. (orig.)

  12. Evaluation of aqueductal patency in patients with hydrocephalus: Three-dimensional high-sampling efficiency technique(SPACE) versus two-dimensional turbo spin echo at 3 Tesla

    International Nuclear Information System (INIS)

    Ucar, Murat; Guryildirim, Melike; Tokgoz, Nil; Kilic, Koray; Borcek, Alp; Oner, Yusuf; Akkan, Koray; Tali, Turgut

    2014-01-01

    To compare the accuracy of diagnosing aqueductal patency and image quality between high spatial resolution three-dimensional (3D) high-sampling-efficiency technique (sampling perfection with application optimized contrast using different flip angle evolutions [SPACE]) and T2-weighted (T2W) two-dimensional (2D) turbo spin echo (TSE) at 3-T in patients with hydrocephalus. This retrospective study included 99 patients diagnosed with hydrocephalus. T2W 3D-SPACE was added to the routine sequences which consisted of T2W 2D-TSE, 3D-constructive interference steady state (CISS), and cine phase-contrast MRI (PC-MRI). Two radiologists evaluated independently the patency of cerebral aqueduct and image quality on the T2W 2D-TSE and T2W 3D-SPACE. PC-MRI and 3D-CISS were used as the reference for aqueductal patency and image quality, respectively. Inter-observer agreement was calculated using kappa statistics. The evaluation of the aqueductal patency by T2W 3D-SPACE and T2W 2D-TSE were in agreement with PC-MRI in 100% (99/99; sensitivity, 100% [83/83]; specificity, 100% [16/16]) and 83.8% (83/99; sensitivity, 100% [67/83]; specificity, 100% [16/16]), respectively (p < 0.001). No significant difference in image quality between T2W 2D-TSE and T2W 3D-SPACE (p = 0.056) occurred. The kappa values for inter-observer agreement were 0.714 for T2W 2D-TSE and 0.899 for T2W 3D-SPACE. Three-dimensional-SPACE is superior to 2D-TSE for the evaluation of aqueductal patency in hydrocephalus. T2W 3D-SPACE may hold promise as a highly accurate alternative treatment to PC-MRI for the physiological and morphological evaluation of aqueductal patency.

  13. Evaluation of aqueductal patency in patients with hydrocephalus: Three-dimensional high-sampling efficiency technique(SPACE) versus two-dimensional turbo spin echo at 3 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Ucar, Murat; Guryildirim, Melike; Tokgoz, Nil; Kilic, Koray; Borcek, Alp; Oner, Yusuf; Akkan, Koray; Tali, Turgut [School of Medicine, Gazi University, Ankara (Turkey)

    2014-12-15

    To compare the accuracy of diagnosing aqueductal patency and image quality between high spatial resolution three-dimensional (3D) high-sampling-efficiency technique (sampling perfection with application optimized contrast using different flip angle evolutions [SPACE]) and T2-weighted (T2W) two-dimensional (2D) turbo spin echo (TSE) at 3-T in patients with hydrocephalus. This retrospective study included 99 patients diagnosed with hydrocephalus. T2W 3D-SPACE was added to the routine sequences which consisted of T2W 2D-TSE, 3D-constructive interference steady state (CISS), and cine phase-contrast MRI (PC-MRI). Two radiologists evaluated independently the patency of cerebral aqueduct and image quality on the T2W 2D-TSE and T2W 3D-SPACE. PC-MRI and 3D-CISS were used as the reference for aqueductal patency and image quality, respectively. Inter-observer agreement was calculated using kappa statistics. The evaluation of the aqueductal patency by T2W 3D-SPACE and T2W 2D-TSE were in agreement with PC-MRI in 100% (99/99; sensitivity, 100% [83/83]; specificity, 100% [16/16]) and 83.8% (83/99; sensitivity, 100% [67/83]; specificity, 100% [16/16]), respectively (p < 0.001). No significant difference in image quality between T2W 2D-TSE and T2W 3D-SPACE (p = 0.056) occurred. The kappa values for inter-observer agreement were 0.714 for T2W 2D-TSE and 0.899 for T2W 3D-SPACE. Three-dimensional-SPACE is superior to 2D-TSE for the evaluation of aqueductal patency in hydrocephalus. T2W 3D-SPACE may hold promise as a highly accurate alternative treatment to PC-MRI for the physiological and morphological evaluation of aqueductal patency.

  14. T2-Weighted 4D Magnetic Resonance Imaging for Application in Magnetic Resonance–Guided Radiotherapy Treatment Planning

    Science.gov (United States)

    Freedman, Joshua N.; Collins, David J.; Bainbridge, Hannah; Rank, Christopher M.; Nill, Simeon; Kachelrieß, Marc; Oelfke, Uwe; Leach, Martin O.; Wetscherek, Andreas

    2017-01-01

    Objectives The aim of this study was to develop and verify a method to obtain good temporal resolution T2-weighted 4-dimensional (4D-T2w) magnetic resonance imaging (MRI) by using motion information from T1-weighted 4D (4D-T1w) MRI, to support treatment planning in MR-guided radiotherapy. Materials and Methods Ten patients with primary non–small cell lung cancer were scanned at 1.5 T axially with a volumetric T2-weighted turbo spin echo sequence gated to exhalation and a volumetric T1-weighted stack-of-stars spoiled gradient echo sequence with golden angle spacing acquired in free breathing. From the latter, 20 respiratory phases were reconstructed using the recently developed 4D joint MoCo-HDTV algorithm based on the self-gating signal obtained from the k-space center. Motion vector fields describing the respiratory cycle were obtained by deformable image registration between the respiratory phases and projected onto the T2-weighted image volume. The resulting 4D-T2w volumes were verified against the 4D-T1w volumes: an edge-detection method was used to measure the diaphragm positions; the locations of anatomical landmarks delineated by a radiation oncologist were compared and normalized mutual information was calculated to evaluate volumetric image similarity. Results High-resolution 4D-T2w MRI was obtained. Respiratory motion was preserved on calculated 4D-T2w MRI, with median diaphragm positions being consistent with less than 6.6 mm (2 voxels) for all patients and less than 3.3 mm (1 voxel) for 9 of 10 patients. Geometrical positions were coherent between 4D-T1w and 4D-T2w MRI as Euclidean distances between all corresponding anatomical landmarks agreed to within 7.6 mm (Euclidean distance of 2 voxels) and were below 3.8 mm (Euclidean distance of 1 voxel) for 355 of 470 pairs of anatomical landmarks. Volumetric image similarity was commensurate between 4D-T1w and 4D-T2w MRI, as mean percentage differences in normalized mutual information (calculated over all

  15. T2-Weighted 4D Magnetic Resonance Imaging for Application in Magnetic Resonance-Guided Radiotherapy Treatment Planning.

    Science.gov (United States)

    Freedman, Joshua N; Collins, David J; Bainbridge, Hannah; Rank, Christopher M; Nill, Simeon; Kachelrieß, Marc; Oelfke, Uwe; Leach, Martin O; Wetscherek, Andreas

    2017-10-01

    The aim of this study was to develop and verify a method to obtain good temporal resolution T2-weighted 4-dimensional (4D-T2w) magnetic resonance imaging (MRI) by using motion information from T1-weighted 4D (4D-T1w) MRI, to support treatment planning in MR-guided radiotherapy. Ten patients with primary non-small cell lung cancer were scanned at 1.5 T axially with a volumetric T2-weighted turbo spin echo sequence gated to exhalation and a volumetric T1-weighted stack-of-stars spoiled gradient echo sequence with golden angle spacing acquired in free breathing. From the latter, 20 respiratory phases were reconstructed using the recently developed 4D joint MoCo-HDTV algorithm based on the self-gating signal obtained from the k-space center. Motion vector fields describing the respiratory cycle were obtained by deformable image registration between the respiratory phases and projected onto the T2-weighted image volume. The resulting 4D-T2w volumes were verified against the 4D-T1w volumes: an edge-detection method was used to measure the diaphragm positions; the locations of anatomical landmarks delineated by a radiation oncologist were compared and normalized mutual information was calculated to evaluate volumetric image similarity. High-resolution 4D-T2w MRI was obtained. Respiratory motion was preserved on calculated 4D-T2w MRI, with median diaphragm positions being consistent with less than 6.6 mm (2 voxels) for all patients and less than 3.3 mm (1 voxel) for 9 of 10 patients. Geometrical positions were coherent between 4D-T1w and 4D-T2w MRI as Euclidean distances between all corresponding anatomical landmarks agreed to within 7.6 mm (Euclidean distance of 2 voxels) and were below 3.8 mm (Euclidean distance of 1 voxel) for 355 of 470 pairs of anatomical landmarks. Volumetric image similarity was commensurate between 4D-T1w and 4D-T2w MRI, as mean percentage differences in normalized mutual information (calculated over all respiratory phases and patients), between

  16. MRI of intracranial vertebral artery dissection: evaluation of intramural haematoma using a black blood, variable-flip-angle 3D turbo spin-echo sequence

    Energy Technology Data Exchange (ETDEWEB)

    Takano, Koichi; Yamashita, Shinnichi; Kuwabara, Yasuo; Yoshimitsu, Kengo [Fukuoka University, Department of Radiology, Faculty of Medicine, Fukuoka-shi, Fukuoka (Japan); Takemoto, Koichiro; Inoue, Tooru [Fukuoka University, Department of Neurosurgery, Faculty of Medicine, Fukuoka (Japan)

    2013-07-15

    We investigated the efficacy of three-dimensional black blood T1-weighted imaging (3D-BB-T1WI) using a variable refocusing flip angle turbo spin-echo sequence in the diagnosis of intracranial vertebral artery dissection (VAD). Sixteen consecutive patients diagnosed with intracranial VAD underwent magnetic resonance imaging that included 3D time-of-flight-MRA, axial spin-echo T1-weighted images (SE-T1WI) and oblique coronal 3D-BB-T1WI sequences. The visualization, morphology and extent of intramural haematomas were assessed and compared among the sequences. Results obtained by digital subtraction angiography (DSA), 3D-angiography and/or 3D-CT angiography (CTA) were used as standards of reference. 3D-BB-T1WI revealed intramural haematomas in all cases, whereas SE-T1WI and magnetic resonance angiography (MRA) failed to reveal a haematoma in one case and three cases, respectively. The mean visualization grading score for the intramural haematoma was the highest for 3D-BB-T1WI, and there was a statistically significant difference among the sequences (p < 0.001). At least a portion of the intramural haematoma was distinguishable from the lumen on 3D-BB-T1WI, whereas the haematomas were entirely indistinguishable from intraluminal signals on MRA in two cases (12.5 %) and on SE-T1WI in one case (6.3 %). 3D-BB-T1WI revealed the characteristic crescent shape of the intramural haematoma in 14 cases (87.5 %), whereas SE-T1WI and MRA revealed a crescent shape in only 7 cases (43.8 %) and 8 cases (50 %), respectively. In a consensus reading, 3D-BB-T1WI was considered the most consistent sequence in representing the extent and morphology of the lesion in 14 cases (87.5 %), compared to DSA and CTA. 3D-BB-T1WI is a promising method to evaluate intramural haematoma in patients with suspected intracranial VAD. (orig.)

  17. Comparison between gadolinium-enhanced 2D T1-weighted gradient-echo and spin-echo sequences in the detection of active multiple sclerosis lesions on 3.0T MRI

    Energy Technology Data Exchange (ETDEWEB)

    Aymerich, F.X. [Hospital Universitari Vall d' Hebron, Universitat Autonoma de Barcelona, MR Unit. Department of Radiology (IDI), Barcelona (Spain); Universitat Politecnica de Catalunya - Barcelona Tech (UPC), Department of Automatic Control (ESAII), Barcelona (Spain); Auger, C.; Alcaide-Leon, P.; Pareto, D.; Huerga, E.; Corral, J.F.; Mitjana, R.; Rovira, A. [Hospital Universitari Vall d' Hebron, Universitat Autonoma de Barcelona, MR Unit. Department of Radiology (IDI), Barcelona (Spain); Sastre-Garriga, J.; Montalban, X. [Hospital Universitari Vall d' Hebron, Universitat Autonoma de Barcelona, Centre d' Esclerosi Multiple de Catalunya (Cemcat), Department of Neurology/Neuroimmunology, Barcelona (Spain)

    2017-04-15

    To compare the sensitivity of enhancing multiple sclerosis (MS) lesions in gadolinium-enhanced 2D T1-weighted gradient-echo (GRE) and spin-echo (SE) sequences, and to assess the influence of visual conspicuity and laterality on detection of these lesions. One hundred MS patients underwent 3.0T brain MRI including gadolinium-enhanced 2D T1-weighted GRE and SE sequences. The two sets of contrast-enhanced scans were evaluated in random fashion by three experienced readers. Lesion conspicuity was assessed by the image contrast ratio (CR) and contrast-to-noise ratio (CNR). The intracranial region was divided into four quadrants and the impact of lesion location on detection was assessed in each slice. Six hundred and seven gadolinium-enhancing MS lesions were identified. GRE images were more sensitive for lesion detection (0.828) than SE images (0.767). Lesions showed a higher CR in SE than in GRE images, whereas the CNR was higher in GRE than SE. Most misclassifications occurred in the right posterior quadrant. The gadolinium-enhanced 2D T1-weighted GRE sequence at 3.0T MRI enables detection of enhancing MS lesions with higher sensitivity and better lesion conspicuity than 2D T1-weighted SE. Hence, we propose the use of gadolinium-enhanced GRE sequences rather than SE sequences for routine scanning of MS patients at 3.0T. (orig.)

  18. Role of EPI in diagnosing cavernous hemangioma and small HCC : comparison with fast T2-weighted MR Imaging

    International Nuclear Information System (INIS)

    Kim, Suk; Lee, Jun Woo; Kim, Chang Won; Jung, Hyun Woo; Choi, Sang Yoel; Lee, Suck Hong; Kim, Byung Soo

    1998-01-01

    The purpose of this study is to compare single-shot echo-planar MR imaging (EPI) with breath-hold fast T2-weighted imaging (HASTE or Turbo spin-echo T2WI) for evaluation of the role of EPI in distinguishing small hepatocellular carcinoma from cavernous hemangioma. We retrospectively evaluated MR images of 35 patients (21 cases of small HCC and 14 cases of cavernous hemangioma). EPI and breath-hold fast T2WI images were obtained and compared on the basis of lesion detection sensitivity, lesion-to-liver signal intensity ratio (SIR), contrast ratio (CR), and lesion-to-liver contrast to noise ratio (CNR). For the detection of small HCC, the sensitivity of EPI and breath-hold fast T2WI were equal in 14 of 21 cases (71.4%). The detection sensitivity of cavernous hemangioma with EPI and breath-hold fast T2WI was 100 % (14/14). Mean SIR on breath-hold fast T2WI was 2.02 ± 0.45 for small HCC and 3.65 ± 0.97 for cavernous hemangioma; on EPI, the corresponding figures were 2.91 ± 0.57 for cavernous hemangioma; On EPI, the figures obtained were 2.27 ± 0.52 and 6.26 ± 2.19, respectively. Mean CNR on breath-hold fast T2WI was 14.24 ± 4.098 for small HCC and 50.28 ± 10.96 for cavernous hemangioma, while on EPI, the corresponding figures were 13.84 ± 3.02 and 45.44 ± 11.21. In detecting focal hepatic mass, the sensitivity of EPI and breath-hold fast T2WI are comparable for the diagnosis of small HCC and cavernous hemangioma, EPI can provided additional information. (author). 20 refs., 2 tabs., 4 figs

  19. T2-weighted imaging of the heart—A pictorial review

    International Nuclear Information System (INIS)

    Mirakhur, Anirudh; Anca, Nicoleta; Mikami, Yoko; Merchant, Naeem

    2013-01-01

    Spin-Echo techniques in cardiovascular magnetic resonance (CMR) have been used for decades, primarily to image cardiac anatomy. More recently, T2-weighted (T2W) imaging has seen an increased role in CMR protocols, especially in tissue characterization in acute myocardial processes. This article will review current methodologies of cardiac T2W acquisition and their limitations, as well as approach to both semi-quantitative and quantitative analyses. The appearance and utility of T2W imaging in a myriad of pathologic myocardial processes such as acute myocardial infarction, acute viral myocarditis, reversible stress-related cardiomyopathy, hypertrophic cardiomyopathy, and cardiac sarcoidosis, will also be discussed

  20. MRI of the anterior talofibular ligament, talar cartilage and os subfibulare: Comparison of isotropic resolution 3D and conventional 2D T2-weighted fast spin-echo sequences at 3.0 T

    Energy Technology Data Exchange (ETDEWEB)

    Yi, Jisook; Cha, Jang Gyu [Soonchunhyang University Bucheon Hospital, Department of Radiology, Wonmi-gu, Bucheon-si (Korea, Republic of); Lee, Young Koo [Soonchunhyang University Bucheon Hospital, Department of Orthopedics, Wonmi-gu, Bucheon-si (Korea, Republic of); Lee, Bo Ra [Soonchunhyang University Bucheon Hospital, Department of Biomedical Statistics, Wonmi-gu, Bucheon-si (Korea, Republic of); Jeon, Chan Hong [Soonchunhyang University Bucheon Hospital, Division of Rheumatology, Department of Internal Medicine, Wonmi-gu, Bucheon-si (Korea, Republic of)

    2016-07-15

    To determine the accuracy of a three-dimensional (3D) T2-weighted fast spin-echo (FSE) magnetic resonance (MR) sequence compared with two-dimensional (2D) sequence for diagnosing anterior talofibular ligament (ATFL) tears, chondral lesion of the talus (CLT) and os subfibulare/avulsion fracture of the distal fibula (OSF). Thirty-five patients were included, who had undergone ankle MRI with 3D T2-weighted FSE and 2D T2-weighted FSE sequences, as well as subsequent ankle arthroscopy, between November 2013 and July 2014. Each MR imaging sequence was independently scored by two readers retrospectively for the presence of ATFL tears, CLT and OSF. The area under the receiver operating curve (AUC) was compared to determine the discriminatory power of the two image sequences. Interobserver agreement was expressed as unweighted kappa value. Arthroscopic findings confirmed 21 complete tears of the ATFL, 14 partial tears of the ATFL, 17 CLTs and 7 OSFs. There were no significant differences in the diagnoses of ATFL tears (p = 0.074-0.501), CLT (p = 0.090-0.450) and OSF (p = 0.317) obtained from the 2D and 3D sequences by either reader. The interobserver agreement rates between two readers using the 3D T2-weighted FSE sequence versus those obtained with the 2D sequence were substantial (κ = 0.659) versus moderate (κ = 0.553) for ATFL tears, moderate (κ = 0.499) versus substantial (κ = 0.676) for CLT and substantial (κ = 0.621) versus substantial (κ = 0.689) for OSF. Three-dimensional isotropic T2-weighted FSE MRI of the ankle resulted in no statistically significant difference in diagnostic performance compared to two-dimensional T2-weighted FSE MRI in the evaluation of ATFL tears, CLTs and OSFs. (orig.)

  1. MRI of the anterior talofibular ligament, talar cartilage and os subfibulare: Comparison of isotropic resolution 3D and conventional 2D T2-weighted fast spin-echo sequences at 3.0 T

    International Nuclear Information System (INIS)

    Yi, Jisook; Cha, Jang Gyu; Lee, Young Koo; Lee, Bo Ra; Jeon, Chan Hong

    2016-01-01

    To determine the accuracy of a three-dimensional (3D) T2-weighted fast spin-echo (FSE) magnetic resonance (MR) sequence compared with two-dimensional (2D) sequence for diagnosing anterior talofibular ligament (ATFL) tears, chondral lesion of the talus (CLT) and os subfibulare/avulsion fracture of the distal fibula (OSF). Thirty-five patients were included, who had undergone ankle MRI with 3D T2-weighted FSE and 2D T2-weighted FSE sequences, as well as subsequent ankle arthroscopy, between November 2013 and July 2014. Each MR imaging sequence was independently scored by two readers retrospectively for the presence of ATFL tears, CLT and OSF. The area under the receiver operating curve (AUC) was compared to determine the discriminatory power of the two image sequences. Interobserver agreement was expressed as unweighted kappa value. Arthroscopic findings confirmed 21 complete tears of the ATFL, 14 partial tears of the ATFL, 17 CLTs and 7 OSFs. There were no significant differences in the diagnoses of ATFL tears (p = 0.074-0.501), CLT (p = 0.090-0.450) and OSF (p = 0.317) obtained from the 2D and 3D sequences by either reader. The interobserver agreement rates between two readers using the 3D T2-weighted FSE sequence versus those obtained with the 2D sequence were substantial (κ = 0.659) versus moderate (κ = 0.553) for ATFL tears, moderate (κ = 0.499) versus substantial (κ = 0.676) for CLT and substantial (κ = 0.621) versus substantial (κ = 0.689) for OSF. Three-dimensional isotropic T2-weighted FSE MRI of the ankle resulted in no statistically significant difference in diagnostic performance compared to two-dimensional T2-weighted FSE MRI in the evaluation of ATFL tears, CLTs and OSFs. (orig.)

  2. Comparison of intravoxel incoherent motion diffusion-weighted imaging between turbo spin-echo and echo-planar imaging of the head and neck

    Energy Technology Data Exchange (ETDEWEB)

    Mikayama, Ryoji; Yabuuchi, Hidetake; Nagatomo, Kazuya; Kimura, Mitsuhiro; Kumazawa, Seiji [Kyushu University, Department of Health Sciences, Graduate School of Medical Sciences, Fukuoka (Japan); Sonoda, Shinjiro; Kobayashi, Koji [Kyushu University Hospital, Division of Radiology, Department of Medical Technology, Fukuoka (Japan); Kawanami, Satoshi; Kamitani, Takeshi; Honda, Hiroshi [Kyushu University, Department of Clinical Radiology, Graduate School of Medical Sciences, Fukuoka (Japan)

    2018-01-15

    To compare image quality, apparent diffusion coefficient (ADC), and intravoxel incoherent motion (IVIM)-derived parameters between turbo spin-echo (TSE)-diffusion-weighted imaging (DWI) and echo-planar imaging (EPI)-DWI of the head and neck. Fourteen volunteers underwent head and neck imaging using TSE-DWI and EPI-DWI. Distortion ratio (DR), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), ADC and IVIM-derived parameters were compared between the two techniques. Bland-Altman analysis was performed to analyse reproducibility between the quantitative parameters of TSE-DWI and EPI-DWI. DR of TSE-DWI was significantly smaller than that of EPI-DWI. SNR and CNR of TSE-DWI were significantly higher than those of EPI-DWI. ADC and IVIM-derived parameters of TSE-DWI showed higher values than those of EPI-DWI, although the difference was not significant. Bland-Altman analysis showed wide limits of agreement between the two sequences. TSE-DWI can produce better image quality than EPI-DWI, while TSE-DWI possibly exhibits different values of quantitative parameters. Therefore, TSE-DWI could be a good alternative to EPI-DWI for patients sensitive to distortion. However, it is not recommended to use both TSE-DWI and EPI-DWI on follow-up. (orig.)

  3. Functional evaluation of transplanted kidneys by Gd-DTPA enhanced turbo FLASH MR imaging

    International Nuclear Information System (INIS)

    Nakashima, Rumi; Yamashita, Yasuyuki; Tomiguchi, Seiji; Tsuji, Akinori; Takahashi, Mutsumasa

    1996-01-01

    We evaluated the usefulness of dynamic turbo FLASH MR imaging in the differential diagnosis of complications after renal transplantation in 17 patients (10 from living relatives and 7 from cadavers). Coronal turbo FLASH dynamic images were obtained every 5 sec for 5 min after an intravenous bolus injection of Gd-DTPA. Corticomedullary differentiation (CMD) on spin echo coronal T 1 -weighted images and MR renogram patterns of the renal cortex and medulla were obtained for quantitative analysis of the Gd-DTPA-enhanced dynamic turbo-FLASH images. The signal intensity ratio of the medulla to cortex after Gd-DTPA enhancement was compared among four groups: normal (n=9), acute tubular necrosis (ATN) or cyclosporine A (CyA) tubulopathy (n=6), acute rejection (AR) in the living related donor kidney (n=4), and AR in the cadaveric kidney (n=5). Although loss of CMD was seen in severe renal dysfunction in the transplanted kidneys, there was considerable overlap among the four groups. On dynamic study, there was significant differences in the signal intensity ratio of the medulla to cortex between normally functioning kidneys or ATN/CyA tubulopathy and AR (p<0.01). In patients with severe renal dysfunction, the arterial cortical peak was indistinct. In conclusion, MR renograms obtained from dynamic turbo FLASH MR imaging played a significant role in evaluating dysfunction of the renal transplant. (author)

  4. Clinical application of Half Fourier Acquisition Single Shot Turbo Spin Echo (HASTE) imaging accelerated by simultaneous multi-slice acquisition.

    Science.gov (United States)

    Schulz, Jenni; P Marques, José; Ter Telgte, Annemieke; van Dorst, Anouk; de Leeuw, Frank-Erik; Meijer, Frederick J A; Norris, David G

    2018-01-01

    As a single-shot sequence with a long train of refocusing pulses, Half-Fourier Acquisition Single-Shot Turbo-Spin-Echo (HASTE) suffers from high power deposition limiting use at high resolutions and high field strengths, particularly if combined with acceleration techniques such as simultaneous multi-slice (SMS) imaging. Using a combination of multiband (MB)-excitation and PINS-refocusing pulses will effectively accelerate the acquisition time while staying within the SAR limitations. In particular, uncooperative and young patients will profit from the speed of the MB-PINS HASTE sequence, as clinical diagnosis can be possible without sedation. Materials and MethodsMB-excitation and PINS-refocusing pulses were incorporated into a HASTE-sequence with blipped CAIPIRINHA and TRAPS including an internal FLASH reference scan for online reconstruction. Whole brain MB-PINS HASTE data were acquired on a Siemens 3T-Prisma system from 10 individuals and compared to a clinical HASTE protocol. ResultsThe proposed MB-PINS HASTE protocol accelerates the acquisition by about a factor 2 compared to the clinical HASTE. The diagnostic image quality proved to be comparable for both sequences for the evaluation of the overall aspect of the brain, the detection of white matter changes and areas of tissue loss, and for the evaluation of the CSF spaces although artifacts were more frequently encountered with MB-PINS HASTE. ConclusionsMB-PINS HASTE enables acquisition of slice accelerated highly T2-weighted images and provides good diagnostic image quality while reducing acquisition time. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Sub-Millimeter T2 Weighted fMRI at 7 T: Comparison of 3D-GRASE and 2D SE-EPI

    Directory of Open Access Journals (Sweden)

    Valentin G. Kemper

    2015-05-01

    Full Text Available Functional magnetic resonance imaging (fMRI allows studying human brain function non-invasively up to the spatial resolution of cortical columns and layers. Most fMRI acquisitions rely on the blood oxygenation level dependent (BOLD contrast employing T2* weighted 2D multi-slice echo-planar imaging (EPI. At ultra-high magnetic field (i.e. 7 T and above, it has been shown experimentally and by simulation, that T2 weighted acquisitions yield a signal that is spatially more specific to the site of neuronal activity at the cost of functional sensitivity. This study compared two T2 weighted imaging sequences, inner-volume 3D Gradient-and-Spin-Echo (3D-GRASE and 2D Spin-Echo EPI (SE-EPI, with evaluation of their imaging point-spread function, functional specificity, and functional sensitivity at sub-millimeter resolution. Simulations and measurements of the imaging point-spread function revealed that the strongest anisotropic blurring in 3D-GRASE (along the second phase-encoding direction was about 60 % higher than the strongest anisotropic blurring in 2D SE-EPI (along the phase-encoding direction In a visual paradigm, the BOLD sensitivity of 3D-GRASE was found to be superior due to its higher temporal signal-to-noise ratio. High resolution cortical depth profiles suggested that the contrast mechanisms are similar between the two sequences, however, 2D SE-EPI had a higher surface bias owing to the higher T2* contribution of the longer in-plane EPI echo-train for full field of view compared to the reduced field of view of zoomed 3D-GRASE.

  6. Comparison of T1-weighted fast spin-echo and T1-weighted fluid-attenuated inversion recovery images of the lumbar spine at 3.0 Tesla

    International Nuclear Information System (INIS)

    Lavdas, Eleftherios; Vlychou, Marianna; Arikidis, Nikos; Kapsalaki, Eftychia; Roka, Violetta; Fezoulidis, Ioannis V.

    2010-01-01

    Background: T1-weighted fluid-attenuated inversion recovery (FLAIR) sequence has been reported to provide improved contrast between lesions and normal anatomical structures compared to T1-weighted fast spin-echo (FSE) imaging at 1.5T regarding imaging of the lumbar spine. Purpose: To compare T1-weighted FSE and fast T1-weighted FLAIR imaging in normal anatomic structures and degenerative and metastatic lesions of the lumbar spine at 3.0T. Material and Methods: Thirty-two consecutive patients (19 females, 13 males; mean age 44 years, range 30-67 years) with lesions of the lumbar spine were prospectively evaluated. Sagittal images of the lumbar spine were obtained using T1-weighted FSE and fast T1-weighted FLAIR sequences. Both qualitative and quantitative analyses measuring the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and relative contrast (ReCon) between degenerative and metastatic lesions and normal anatomic structures were conducted, comparing these sequences. Results: On quantitative evaluation, SNRs of cerebrospinal fluid (CSF), nerve root, and fat around the root of fast T1-weighted FLAIR imaging were significantly lower than those of T1-weighted FSE images (P<0.001). CNRs of normal spinal cord/CSF and disc herniation/ CSF for fast T1-weighted FLAIR images were significantly higher than those for T1-weighted FSE images (P<0.001). ReCon of normal spinal cord/CSF, disc herniation/CSF, and vertebral lesions/CSF for fast T1-weighted FLAIR images were significantly higher than those for T1-weighted FSE images (P<0.001). On qualitative evaluation, it was found that CSF nulling and contrast at the spinal cord (cauda equina)/CSF interface for T1-weighted FLAIR images were significantly superior compared to those for T1-weighted FSE images (P<0.001), and the disc/spinal cord (cauda equina) interface was better for T1-weighted FLAIR images (P<0.05). Conclusion: The T1-weighted FLAIR sequence may be considered as the preferred lumbar spine imaging

  7. MRI of focal liver lesions using a 1.5T turbo-spinecho technique compared with spinecho technique; MRT fokaler Leberlaesionen bei 1,5T Turbo-Spinecho im Vergleich mit der Spinecho-Technik

    Energy Technology Data Exchange (ETDEWEB)

    Steiner, S. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Vogl, T.J. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Fischer, P. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Steger, W. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Neuhaus, P. [Chirurgische Klinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Keck, H. [Chirurgische Klinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany)

    1995-08-01

    In our study 35 patients with suspected focal liver lesions were examined. Standardised imaging protocol included a conventional T{sub 2}-weighted SE sequence (T{sub R}/T{sub E} = 2000/90/45, acquisition time = 10.20) as well as a T{sub 2}-weighted TSE sequence (T{sub R}/T{sub E} = 4700/90, acquisition time = 6.33). Calculation of S/N and C/N ratio as a basis of quantitative evaluation was done using standard methods. A diagnostic score was implemented to enable qualitative assessment. In 7% (n=2) the TSE sequence enabled detection of further liver lesions showing a size of less than 1 cm in diameter. Comparing anatomical details the TSE sequence was superior. S/N and C/N ratio of anatomic and pathologic structures of the TSE sequence were higher compared to results of the SE sequence. (orig./MG) [Deutsch] In einer prospektiven Studie wurden 35 Patienten mit fokalen Leberlaesionen untersucht. Das standardisierte Untersuchungsschema der Studie umfasste eine konventionelle SE-Sequenz mit T{sub R}/T{sub E} = 2000/90/45 (Akquisitionszeit = 10,20 min) sowie eine TSE-Sequenz mit T{sub R}/T{sub E} = 4700/90 (Akquisitionszeit = 6.33 min). Die Berechnung des S/R- sowie der K/R-Quotienten als Grundlage des quantitativen Vergleichs erfolgte nach Standardmethoden. Der qualitative Vergleich beider Sequenzen erfolgte durch Einschaetzung der Bildqualitaet anhand eines Stufenschemas. In 7% (n=2) konnten mit Hilfe der TSE-Sequenz mehr suspekte Laesionen detektiert werden. Ein Vergleich der Darstellung der anatomischen Detailerkennbarkeit zeigte Ueberlegenheit der TSE-Sequenz. Die S/R-Quotienten und K/R-Quotienten bezogen auf anatomische und pathologische Strukturen wiesen fuer die Turbo-Spinecho-Sequenz hoehere Werte auf. (orig./MG)

  8. Centrically reordered inversion recovery half-Fourier single-shot turbo spin-echo sequence: improvement of the image quality of oxygen-enhanced MRI

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Hatabu, Hiroto; Higashino, Takanori; Kawamitsu, Hideaki; Watanabe, Hirokazu; Takenaka, Daisuke; Cauteren, Marc van; Sugimura, Kazuro

    2004-01-01

    Purpose: The purpose of the study presented here was to determine the improvement in image quality of oxygen-enhanced magnetic resonance (MR) subtraction imaging obtained with a centrically reordered inversion recovery half-Fourier single-shot turbo spin-echo (c-IR-HASTE) sequence compared with that obtained with a conventional sequentially reordered inversion recovery single-shot HASTE (s-IR-HASTE) sequence for pulmonary imaging. Materials and methods: Oxygen-enhanced MR imaging using a 1.5 T whole body scanner was performed on 12 healthy, non-smoking volunteers. Oxygen-enhanced MR images were obtained with the coronal two-dimensional (2D) c-IR-HASTE sequence and 2D s-IR-HASTE sequence combined with respiratory triggering. For a 256x256 matrix, 132 phase-encoding steps were acquired including four steps for phase correction. Inter-echo spacing for each sequence was 4.0 ms. The effective echo time (TE) for c-IR-HASTE was 4.0 ms, and 16 ms for s-IR-HASTE. The inversion time (TI) was 900 ms. To determine the improvement in oxygen-enhanced MR subtraction imaging by c-IR-HASTE, CNRs of subtraction image, overall image quality, and image degradation of the c-IR-HASTE and s-IR-HASTE techniques were statistically compared. Results: CNR, overall image quality, and image degradation of c-IR-HASTE images showed significant improvement compared to those s-IR-HASTE images (P<0.05). Conclusion: Centrically reordered inversion recovery half-Fourier single-shot turbo spin-echo (c-IR-HASTE) sequence enhanced the signal from the lung and improved the image quality of oxygen-enhanced MR subtraction imaging

  9. Diagnosis of spinal dural arteriovenous fistula using 3D T2-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kralik, Stephen F.; Murph, Daniel; Mehta, Peter; O' Neill, Darren P. [Indiana University School of Medicine, Department of Radiology and Imaging Sciences, Indianapolis, IN (United States)

    2017-10-15

    To evaluate spinal MRIs without and with 3D T2W imaging among patients without and with spinal dural arteriovenous fistula (SDAVF) confirmed by spinal digital subtraction angiography (DSA). A retrospective case-control study was performed among patients without and with SDAVF who had both spinal MRIs and gold standard spinal DSA. Two neuroradiologists independently reviewed spinal MRIs that were performed with either sagittal T2W turbo spin echo (2D group) or sagittal 3D T2W sampling perfection with application-optimized contrasts using different flip-angle evolutions (SPACE) (3D group) and documented the presence or absence of SDAVF. Using spinal DSA diagnosis as a gold standard, the sensitivity, specificity, and interobserver agreement for the 2D-group and 3D-group MRI diagnosis were calculated. The 2D group consisted of 21 patients and the 3D group consisted of 16 patients. For both radiologists, the 2D group demonstrated a sensitivity of 100% and specificity of 100%. Interobserver agreement in the 2D group was perfect (k = 1.0). For both radiologists, the 3D group demonstrated sensitivity of 100.0% and specificity of 92.3%. Interobserver agreement in the 3D group was perfect (k = 1.0). While flow voids were considered more conspicuous, spinal cord signal abnormality was considered less conspicuous with 3D T2W SPACE compared with conventional 2D STIR sequence. 3D T2W SPACE should be used in conjunction with 2D T2W sequences to more accurately detect abnormal cord signal and determine when perimedullary flow voids are pathologically abnormal for the radiologic diagnosis of SDAVF. (orig.)

  10. Design of universal parallel-transmit refocusing kT -point pulses and application to 3D T2 -weighted imaging at 7T.

    Science.gov (United States)

    Gras, Vincent; Mauconduit, Franck; Vignaud, Alexandre; Amadon, Alexis; Le Bihan, Denis; Stöcker, Tony; Boulant, Nicolas

    2018-07-01

    T 2 -weighted sequences are particularly sensitive to the radiofrequency (RF) field inhomogeneity problem at ultra-high-field because of the errors accumulated by the imperfections of the train of refocusing pulses. As parallel transmission (pTx) has proved particularly useful to counteract RF heterogeneities, universal pulses were recently demonstrated to save precious time and computational efforts by skipping B 1 calibration and online RF pulse tailoring. Here, we report a universal RF pulse design for non-selective refocusing pulses to mitigate the RF inhomogeneity problem at 7T in turbo spin-echo sequences with variable flip angles. Average Hamiltonian theory was used to synthetize a single non-selective refocusing pulse with pTx while optimizing its scaling properties in the presence of static field offsets. The design was performed under explicit power and specific absorption rate constraints on a database of 10 subjects using a 8Tx-32Rx commercial coil at 7T. To validate the proposed design, the RF pulses were tested in simulation and applied in vivo on 5 additional test subjects. The root-mean-square rotation angle error (RA-NRMSE) evaluation and experimental data demonstrated great improvement with the proposed universal pulses (RA-NRMSE ∼8%) compared to the standard circularly polarized mode of excitation (RA-NRMSE ∼26%). This work further completes the spectrum of 3D universal pulses to mitigate RF field inhomogeneity throughout all 3D MRI sequences without any pTx calibration. The approach returns a single pulse that can be scaled to match the desired flip angle train, thereby increasing the modularity of the proposed plug and play approach. Magn Reson Med 80:53-65, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  11. Comparison of single-shot fast spin-echo sequence and T2-weighted fast spin-echo sequence in MR imaging of the brain

    International Nuclear Information System (INIS)

    Cha, Sung Ho; Seo, Jeong Jin; Jeong, Gwang Woo; Kim, Jae Kyu; Kim, Yun Hyeon; Jeong, Yong Yeon; Kang, Heoung Keun; Oh, Hee Yeon; Yoon, Jong Hoon

    1998-01-01

    The purpose of this study was to evaluate the usefulness of the single-shot fast spinecho (SS-FSE) sequence in comparison with the T2-weighted fast spin-echo (T2-FSE) sequence in brain MR imaging. In 41 patients aged 15-75 years with intracranial lesion, both SS-FSE and T2-FES images were obtained using a 1.5-T MR system. Lesions included cerebral ischemia or infarcts (n=3D23), tumors (n=3D10), hemorrhages (n=3D3), inflammatory diseases (n=3D2), arachnoid cysts(n=3D2), and vascular disease (n=3D1), and the MR images were retrospectively evaluated. To calculate contrast-to-noise ratio (CNR), percentage contrast, and signal-to-noise ratio (SNR)-and thus make a quantitative comparison-the mean signal intensities of lesions, normal brain tissue, and noise out-side the patient were measured. For qualitative comparison, the visibility, margin, and extent of the lesions were rated using a five-grade system, and the degree of MR artifacts was also evaluated. Wilcoxon's signed ranks test was used for statistical analysis. The mean CNR of lesions was significantly higher on SS-FSE (31.3) than on T2-FSE images (27.5) (p=3D0.0131). Mean percentage contrast was also higher on SS-FSE (159.0) than on T2-FSE images (108.5) (p=3D0.0222), but mean SNR was higher on T2-FSE (80.3) than on SS-FSE images (53.5) (p=3D0.0000). No significant differences in lesion visibility were observed between the two imaging sequences, though margin and extent of the lesion were worse on SS-FSE images. For MR artifacts, no significant differences were demonstrated. For the evaluation of most intracranial lesions, MR imaging using the SS-FSE sequence appears to be slightly inferior to the T2-FSE sequence, but may be useful where patients are ill or uncooperative, or where children require sedation.=20

  12. Comparison between T2*- and T2-weighted images in diagnosing rotator cuff tears

    International Nuclear Information System (INIS)

    Kumagai, Hideo; Ito, Hisao; Kubo, Atsushi.

    1995-01-01

    This study was performed to determine the merits of T2 * -weighted images in diagnosing rotator cuff tear, compared with T2-weighted images. T2- and T2 * -weighted images were obtained in 10 asymptomatic volunteers and 94 patients with symptoms referable to the rotator cuff. The increased signal with full thickness of the rotator cuff was not shown on either T2- or T2 * -weighted images in the volunteers. These findings on T2-weighted images and on T2 * -weighted images were observed in 33 and 58 of 94 patients with symptoms, respectively. Every patient who showed these abnormal findings on T2-weighted images had the abnormal findings on T2 * -weighted images. These findings on T2 * -weighted images were wider than those on T2-weighted images in 20 of 33 patients. Surgical findings were available in 21 of 94 patients. Rotator cuff tears were surgically confirmed in 20 patients whose MR images showed increased signal lesions on both T2- and T2 * -weighted images. On the other hand, one patient who did not have rotator cuff tear showed increased signal lesion with full thickness on T2 * -weighted images, but not on T2-weighted images. We think increased signal lesions on T2-weighted images may strongly suggest rotator cuff tear, whereas those on T2 * -weighted images are not specific. (author)

  13. BLADE acquisition method improves T2-weighted MR images of the female pelvis compared with a standard fast spin-echo sequence

    International Nuclear Information System (INIS)

    Fujimoto, Koji; Koyama, Takashi; Tamai, Ken; Morisawa, Nobuko; Okada, Tomohisa; Togashi, Kaori

    2011-01-01

    Purpose: To investigate feasibility of the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER or BLADE) T2-weighted imaging (T2WI) of the female pelvis by comparing it with standard fast spin-echo T2WI (STD-T2WI). Materials and methods: Sagittal STD-T2WI and BLADE-T2WI of the female pelvis were performed with (36 patients) or without (15 patients) administration of butylscopolamine on a 1.5 T MR unit. Two radiologists independently rated depiction of the uterus, ovary, intestines, bladder, gynecological lesions, overall quality, and artifacts using a four-point scale. Results were compared between STD-T2WI vs. BLADE-T2WI either with (B+) or without (B−) administration of butylscopolamine, BLADE-T2WI (B−) vs. BLADE-T2WI (B+), and STD-T2WI (B+) vs. BLADE-T2WI (B−). Results: When butylscopolamine was administrated, depiction of the uterus, ovary, intestines, gynecological lesions, and overall image quality was rated higher and artifacts were rated fewer for BLADE-T2WI with significance compared with STD-T2WI. When the drug was not administrated, significant difference was observed in depiction of the lesion, overall quality, and artifacts. Depiction of the uterus, gynecological lesion, and overall quality was rated significantly higher and artifacts were fewer in BLADE-T2WI (B+) than in BLADE-T2WI (B−). Conclusion: BLADE method was feasible for female pelvic MRI, with best image quality in BLADE-T2WI (B+).

  14. The Usefulness of Fast-Spin-Echo T2-Weighted MR Imaging in Nutcracker Syndrome: a Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Wong, Heong Leng; Chen, Matt Chiung Yu; Wu, Cgek Siung; Fu, Kuo An; Lin, Cheng Hao [Yuan' s General Hospital, Kaohsiung (China); Weng, Mei Jui; Liang, Huei Lung; Pan, Huay Ben [National Yang-Ming University, Taipei (Korea, Republic of)

    2010-06-15

    Nutcracker syndrome occurs when the left renal vein (LRV) is compressed between the superior mesenteric artery and the aorta, and this syndrome is often characterized by venous hypertension and related pathologies. However, invasive studies such as phlebography and measuring the reno-caval pressure gradient should be performed to identify venous hypertension. Here we present a case of Nutcracker syndrome where the LRV and intra-renal varicosities appeared homogeneously hyperintense on magnetic resonance (MR) fast-spin-echo T2- weighted imaging, which suggested markedly stagnant intravenous blood flow and the presence of venous hypertension. The patient was diagnosed and treated without obtaining the reno-caval pressure gradient. The discomfort of the patient lessened after treatment. Furthermore, on follow-up evaluation, the LRV displayed a signal void, and this was suggestive of a restoration of the normal LRV flow and a decrease in LRV pressure.

  15. SU-F-I-16: Short Breast MRI with High-Resolution T2-Weighted and Dynamic Contrast Enhanced T1-Weighted Images

    International Nuclear Information System (INIS)

    Ma, J; Son, J; Arun, B; Hazle, J; Hwang, K; Madewell, J; Yang, W; Dogan, B; Wang, K; Bayram, E

    2016-01-01

    Purpose: To develop and demonstrate a short breast (sb) MRI protocol that acquires both T2-weighted and dynamic contrast-enhanced T1-weighted images in approximately ten minutes. Methods: The sb-MRI protocol consists of two novel pulse sequences. The first is a flexible fast spin-echo triple-echo Dixon (FTED) sequence for high-resolution fat-suppressed T2-weighted imaging, and the second is a 3D fast dual-echo spoiled gradient sequence (FLEX) for volumetric fat-suppressed T1-weighted imaging before and post contrast agent injection. The flexible FTED sequence replaces each single readout during every echo-spacing period of FSE with three fast-switching bipolar readouts to produce three raw images in a single acquisition. These three raw images are then post-processed using a Dixon algorithm to generate separate water-only and fat-only images. The FLEX sequence acquires two echoes using dual-echo readout after each RF excitation and the corresponding images are post-processed using a similar Dixon algorithm to yield water-only and fat-only images. The sb-MRI protocol was implemented on a 3T MRI scanner and used for patients who had undergone concurrent clinical MRI for breast cancer screening. Results: With the same scan parameters (eg, spatial coverage, field of view, spatial and temporal resolution) as the clinical protocol, the total scan-time of the sb-MRI protocol (including the localizer, bilateral T2-weighted, and dynamic contrast-enhanced T1-weighted images) was 11 minutes. In comparison, the clinical breast MRI protocol took 43 minutes. Uniform fat suppression and high image quality were consistently achieved by sb-MRI. Conclusion: We demonstrated a sb-MRI protocol comprising both T2-weighted and dynamic contrast-enhanced T1-weighted images can be performed in approximately ten minutes. The spatial and temporal resolution of the images easily satisfies the current breast MRI accreditation guidelines by the American College of Radiology. The protocol has the

  16. SU-F-I-16: Short Breast MRI with High-Resolution T2-Weighted and Dynamic Contrast Enhanced T1-Weighted Images

    Energy Technology Data Exchange (ETDEWEB)

    Ma, J; Son, J; Arun, B; Hazle, J; Hwang, K; Madewell, J; Yang, W; Dogan, B [UT MD Anderson Cancer Center, Houston, TX (United States); Wang, K; Bayram, E [GE Healthcare Technologies, Waukesha, Wisconsin (United States)

    2016-06-15

    Purpose: To develop and demonstrate a short breast (sb) MRI protocol that acquires both T2-weighted and dynamic contrast-enhanced T1-weighted images in approximately ten minutes. Methods: The sb-MRI protocol consists of two novel pulse sequences. The first is a flexible fast spin-echo triple-echo Dixon (FTED) sequence for high-resolution fat-suppressed T2-weighted imaging, and the second is a 3D fast dual-echo spoiled gradient sequence (FLEX) for volumetric fat-suppressed T1-weighted imaging before and post contrast agent injection. The flexible FTED sequence replaces each single readout during every echo-spacing period of FSE with three fast-switching bipolar readouts to produce three raw images in a single acquisition. These three raw images are then post-processed using a Dixon algorithm to generate separate water-only and fat-only images. The FLEX sequence acquires two echoes using dual-echo readout after each RF excitation and the corresponding images are post-processed using a similar Dixon algorithm to yield water-only and fat-only images. The sb-MRI protocol was implemented on a 3T MRI scanner and used for patients who had undergone concurrent clinical MRI for breast cancer screening. Results: With the same scan parameters (eg, spatial coverage, field of view, spatial and temporal resolution) as the clinical protocol, the total scan-time of the sb-MRI protocol (including the localizer, bilateral T2-weighted, and dynamic contrast-enhanced T1-weighted images) was 11 minutes. In comparison, the clinical breast MRI protocol took 43 minutes. Uniform fat suppression and high image quality were consistently achieved by sb-MRI. Conclusion: We demonstrated a sb-MRI protocol comprising both T2-weighted and dynamic contrast-enhanced T1-weighted images can be performed in approximately ten minutes. The spatial and temporal resolution of the images easily satisfies the current breast MRI accreditation guidelines by the American College of Radiology. The protocol has the

  17. Basic evaluation of the new pulse sequence for simultaneous acquisition of T1- and T2-weighted images

    International Nuclear Information System (INIS)

    Kurose, Atsunari; Takahashi, Tohru; Ohishi, Tae; Ishikawa, Akihiro

    2006-01-01

    A novel pulse sequence that enables simultaneous acquisition of T1-weighted (T1W) and T2-weighted (T2W) images is presented. In this new technique, the inversion recovery (IR) pulse of conventional fast inversion recovery (Fast IR) is replaced with a pulse train that consists of a fast spin echo (FSE) and 180(y)+90(x) for driven inversion (DI). By using a shorter T1 and independent k-space ordering, the first part of the sequence provides T2W images and the second part provides T1W images, thereby enabling simultaneous acquisition in a single scan time comparable to that of Fast IR. Signal simulation also was conducted, and this was compared with conventional scanning techniques using normal volunteers. In the human studies, both T1W and T2W images showed the same image quality as conventional images, suggesting the potential for this technique to replace the combination of Fast IR and T2W FSE for scan-time reduction. (author)

  18. Magnetic resonance imaging of pulmonary infection in immunocompromised children: comparison with multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ozcan, H.N.; Gormez, Aysegul; Oguz, Berna; Haliloglu, Mithat [Hacettepe University School of Medicine, Department of Radiology, Ankara (Turkey); Ozsurekci, Yasemin; Ceyhan, Mehmet [Hacettepe University School of Medicine, Department of Pediatric Infectious Disease, Ankara (Turkey); Karakaya, Jale [Hacettepe University School of Medicine, Department of Biostatistics, Ankara (Turkey); Unal, Sule; Cetin, Mualla [Hacettepe University School of Medicine, Department of Pediatric Hematology, Ankara (Turkey)

    2017-02-15

    Computed tomography (CT) is commonly used to detect pulmonary infection in immunocompromised children. To compare MRI and multidetector CT findings of pulmonary abnormalities in immunocompromised children. Seventeen neutropaenic children (6 girls; ages 2-18 years) were included. Non-contrast-enhanced CT was performed with a 64-detector CT scanner. Axial and coronal non-enhanced thoracic MRI was performed using a 1.5-T scanner within 24 h of the CT examination (true fast imaging with steady-state free precession, fat-saturated T2-weighted turbo spin echo with motion correction, T2-weighted half-Fourier single-shot turbo spin echo [HASTE], fat-saturated T1-weighted spoiled gradient echo). Pulmonary abnormalities (nodules, consolidations, ground glass opacities, atelectasis, pleural effusion and lymph nodes) were evaluated and compared among MRI sequences and between MRI and CT. The relationship between MRI sequences and nodule sizes was examined by chi- square test. Of 256 CT lesions, 207 (81%, 95% confidence interval [CI] 76-85%) were detected at MRI. Of 202 CT-detected nodules, 157 (78%, 95% CI 71-83%) were seen at motion-corrected MRI. Of the 1-5-mm nodules, 69% were detected by motion-corrected T2-weighted MRI and 38% by HASTE MRI. Sensitivity of MRI (both axial fat-saturated T2-weighted turbo spin echo with variable phase encoding directions (BLADE) images and HASTE sequences) to detect pulmonary abnormalities is promising. (orig.)

  19. Magnetic resonance imaging of pulmonary infection in immunocompromised children: comparison with multidetector computed tomography.

    Science.gov (United States)

    Ozcan, H Nursun; Gormez, Ayşegul; Ozsurekci, Yasemin; Karakaya, Jale; Oguz, Berna; Unal, Sule; Cetin, Mualla; Ceyhan, Mehmet; Haliloglu, Mithat

    2017-02-01

    Computed tomography (CT) is commonly used to detect pulmonary infection in immunocompromised children. To compare MRI and multidetector CT findings of pulmonary abnormalities in immunocompromised children. Seventeen neutropaenic children (6 girls; ages 2-18 years) were included. Non-contrast-enhanced CT was performed with a 64-detector CT scanner. Axial and coronal non-enhanced thoracic MRI was performed using a 1.5-T scanner within 24 h of the CT examination (true fast imaging with steady-state free precession, fat-saturated T2-weighted turbo spin echo with motion correction, T2-weighted half-Fourier single-shot turbo spin echo [HASTE], fat-saturated T1-weighted spoiled gradient echo). Pulmonary abnormalities (nodules, consolidations, ground glass opacities, atelectasis, pleural effusion and lymph nodes) were evaluated and compared among MRI sequences and between MRI and CT. The relationship between MRI sequences and nodule sizes was examined by chi- square test. Of 256 CT lesions, 207 (81%, 95% confidence interval [CI] 76-85%) were detected at MRI. Of 202 CT-detected nodules, 157 (78%, 95% CI 71-83%) were seen at motion-corrected MRI. Of the 1-5-mm nodules, 69% were detected by motion-corrected T2-weighted MRI and 38% by HASTE MRI. Sensitivity of MRI (both axial fat-saturated T2-weighted turbo spin echo with variable phase encoding directions (BLADE) images and HASTE sequences) to detect pulmonary abnormalities is promising.

  20. Magnetic resonance imaging of pulmonary infection in immunocompromised children: comparison with multidetector computed tomography

    International Nuclear Information System (INIS)

    Ozcan, H.N.; Gormez, Aysegul; Oguz, Berna; Haliloglu, Mithat; Ozsurekci, Yasemin; Ceyhan, Mehmet; Karakaya, Jale; Unal, Sule; Cetin, Mualla

    2017-01-01

    Computed tomography (CT) is commonly used to detect pulmonary infection in immunocompromised children. To compare MRI and multidetector CT findings of pulmonary abnormalities in immunocompromised children. Seventeen neutropaenic children (6 girls; ages 2-18 years) were included. Non-contrast-enhanced CT was performed with a 64-detector CT scanner. Axial and coronal non-enhanced thoracic MRI was performed using a 1.5-T scanner within 24 h of the CT examination (true fast imaging with steady-state free precession, fat-saturated T2-weighted turbo spin echo with motion correction, T2-weighted half-Fourier single-shot turbo spin echo [HASTE], fat-saturated T1-weighted spoiled gradient echo). Pulmonary abnormalities (nodules, consolidations, ground glass opacities, atelectasis, pleural effusion and lymph nodes) were evaluated and compared among MRI sequences and between MRI and CT. The relationship between MRI sequences and nodule sizes was examined by chi- square test. Of 256 CT lesions, 207 (81%, 95% confidence interval [CI] 76-85%) were detected at MRI. Of 202 CT-detected nodules, 157 (78%, 95% CI 71-83%) were seen at motion-corrected MRI. Of the 1-5-mm nodules, 69% were detected by motion-corrected T2-weighted MRI and 38% by HASTE MRI. Sensitivity of MRI (both axial fat-saturated T2-weighted turbo spin echo with variable phase encoding directions (BLADE) images and HASTE sequences) to detect pulmonary abnormalities is promising. (orig.)

  1. Comparison of MR sequences in early cerebral infarction at 0.5 T

    International Nuclear Information System (INIS)

    Saatci, I.; Baskan, O.; Cekirge, H.S.; Besim, A.

    2000-01-01

    To compare the diagnostic values of fluid-attenuated inversion recovery (FLAIR) and gradient spin-echo (GRASE) with those of conventional spin-echo (SE) and fast SE T2-weighted sequences in the evaluation of acute cerebrovascular lesions at 0.5 T. Material and Methods: Twenty-two consecutive patients with the clinical diagnosis of acute cerebrovascular accident were examined by MR imaging within the first 48 h of ictus. MR examination included 5-mm axial conventional SE and turbo SE (TSE) T2-weighted, dual-echo GRASE and FLAIR sequences. The patients also had pre- and postcontrast T1-weighted axial images. Two examiners evaluated the images and scored the conspicuity of the acute lesions. Results: Regardless of location, FLAIR provided the best lesion conspicuity in the detection of acute infarcts, followed by the GRASE sequence. In the posterior fossa, TSE and SE demonstrated the lesions better than GRASE and FLAIR techniques. In the detection of hemorrhagic elements within the ischemic region, TSE demonstrated statistically significant superiority over other sequences. Conclusion: In the detection of acute ischemic lesions in locations other than the posterior fossa, FLAIR provided the best lesion conspicuity among four T2-weighted sequences, including SE, TSE, GRASE and FLAIR. However, for the posterior fossa examination, preference of SE or TSE T2-weighted sequences is suggested

  2. Comparison of MR sequences in early cerebral infarction at 0.5 T

    Energy Technology Data Exchange (ETDEWEB)

    Saatci, I.; Baskan, O.; Cekirge, H.S.; Besim, A. [Hacettepe Univ. Hospital, Ankara (Turkey). Radiology Dept.

    2000-11-01

    To compare the diagnostic values of fluid-attenuated inversion recovery (FLAIR) and gradient spin-echo (GRASE) with those of conventional spin-echo (SE) and fast SE T2-weighted sequences in the evaluation of acute cerebrovascular lesions at 0.5 T. Material and Methods: Twenty-two consecutive patients with the clinical diagnosis of acute cerebrovascular accident were examined by MR imaging within the first 48 h of ictus. MR examination included 5-mm axial conventional SE and turbo SE (TSE) T2-weighted, dual-echo GRASE and FLAIR sequences. The patients also had pre- and postcontrast T1-weighted axial images. Two examiners evaluated the images and scored the conspicuity of the acute lesions. Results: Regardless of location, FLAIR provided the best lesion conspicuity in the detection of acute infarcts, followed by the GRASE sequence. In the posterior fossa, TSE and SE demonstrated the lesions better than GRASE and FLAIR techniques. In the detection of hemorrhagic elements within the ischemic region, TSE demonstrated statistically significant superiority over other sequences. Conclusion: In the detection of acute ischemic lesions in locations other than the posterior fossa, FLAIR provided the best lesion conspicuity among four T2-weighted sequences, including SE, TSE, GRASE and FLAIR. However, for the posterior fossa examination, preference of SE or TSE T2-weighted sequences is suggested.

  3. 3D Ultrashort TE MRI for Evaluation of Cartilaginous Endplate of Cervical Disk In Vivo: Feasibility and Correlation With Disk Degeneration in T2-Weighted Spin-Echo Sequence.

    Science.gov (United States)

    Kim, Yeo Ju; Cha, Jang Gyu; Shin, Yoon Sang; Chaudhari, Akshay S; Suh, Young Ju; Hwan Yoon, Seung; Gold, Garry E

    2018-05-01

    The purpose of this study was to evaluate the feasibility of 3D ultrashort TE (UTE) MRI in depicting the cartilaginous endplate (CEP) and its abnormalities and to investigate the association between CEP abnormalities and disk degeneration on T2-weighted spin-echo (SE) MR images in cervical disks in vivo. Eight healthy volunteers and 70 patients were examined using 3-T MRI with the 3D UTE cones trajectory technique (TR/TE, 16.1/0.032, 6.6). In the volunteer study, quantitative and qualitative assessments of CEP depiction were conducted for the 3D UTE and T2-weighted SE imaging. In the patient study, CEP abnormalities were analyzed. Intersequence agreement between the images obtained with the first-echo 3D UTE sequence and the images created by subtracting the second-echo from the first-echo 3D UTE sequence (subtracted 3D UTE) and the intraobserver and interobserver agreements for 3D UTE overall were also tested. The CEP abnormalities on the 3D UTE images correlated with the Miyazaki grading of the T2-weighted SE images. In the volunteer study, the CEP was well visualized on 3D UTE images but not on T2-weighted SE images (p evaluation of CEP abnormalities, intersequence agreements were substantial to almost perfect, intraobserver agreements were substantial to almost perfect, and interobserver agreements were moderate to substantial (p T2-weighted SE MRI.

  4. Utility of single shot fast spin echo technique in evaluating pancreaticobiliary diseases: T2-weighted image and magnetic resonance cholangiopancreatography

    International Nuclear Information System (INIS)

    Choi, Byoung Wook; Kim, Myeong Jin; Chung, Jae Bok; Ko, Heung Kyu; Kim, Dong Joon; Kim, Joo Hee; Chung, Jae Joon; Yoo, Hyung Sik; Lee, Jong Tae

    1999-01-01

    To evaluate the accuracy of T2-weighted imaging an MR cholangiopancreatography using the single shot fast spin-echo technique for evaluating pancreaticobiliary disease. Between March and July 1997, axial and coronal T2-weighted images(TE: 80-200 msec) and MR cholangiopancreatograms (TE: 800-1200 msec) were obtained in two ways [single slab (thickness: 30-50 mm) and multislice acquisition under chemical fat saturation] using SSFSE pulse sequencing in 131 cases of suspected pancreati-cobiliary disease. The accuracy of SSFSE MR imaging was assessed in 89 lesions of 74 patients [male, 48; female, 26; age range, 30-86 (mean, 59) years] confirmed surgicopathologically (50 lesions in 39 patients) and clinically (39 lesions in 35 patients). Two radiologists reviewed the MR images and diagnosis was determined by consensus. Correct diagnosis was confirmed in 84 of 89 lesions (94%). Seven lesions were falsely interpreted, false positive and false negative results accounting for two and five cases, respectively. Two pancreatic cancers were misdiagnosed as pancreatitis and a cancer of the proximal common bile duct(CBD) was interpreted as a distal CBD cancer. The sensitivity of SSFSE MR imaging for malignancy was 93 %. One CBD stone revealed by endoscopic retrograde cholangiopancreatography (ERCP) was not detected on MR images. In contrast, a stone in the CBD seen on MR images was not apparent on subsequent ERCP. Sensitivity and specificity for calculous disease were 96% and 99.7%, respectively. A benign stricture of the ampulla of Vater was falsely interpreted as normal, and correct diagnosis was possible in two falsely diagnosed cases when MR images were reviewed retrospectively. The combination of T2-weighted and cholangiographic images using SSFSE is an accurate method for diagnosing pancreatcobiliary diseases

  5. Fat-suppressed fast spin-echo mid-TE (TE[effective]=34) MR images: comparison with fast spin-echo T2-weighted images for the diagnosis of tears and anatomic variants of the glenoid labrum

    Energy Technology Data Exchange (ETDEWEB)

    Tuite, M J [Dept. of Radiology, Univ. of Wisconsin School of Medicine, Madison (United States); University of Wisconsin Hospital and Clinics, Dept. of Radiology, Madison, WI (United States); Shinners, T J; Hollister, M C [Dept. of Radiology, Univ. of Wisconsin School of Medicine, Madison (United States); Orwin, J F [Dept. of Orthopedic Surgery, University of Wisconsin School of Medicine, Madison (United States)

    1999-12-01

    Objective. To compare the sensitivity, specificity, and accuracy of fat-suppressed fast spin-echo (FSE) mid-TE (TE[effective]=34) images with fat-suppressed FSE T2-weighted images for the diagnosis of labral abnormalities.Design and patients. The study included 27 consecutive patients who had axial fat-suppressed FSE T2-weighted and fat-suppressed FSE mid-TE MR images, and had labral abnormalities diagnosed at arthroscopy. The acquisition time was about 5 min for each sequence, but the mid-TE sequence allowed a higher spatial resolution than the T2-weighted images (256 x 256 versus 256 x 192). Twenty-eight age-matched patients with arthroscopically normal labra were included as a control group. The labrum was graded on the MR images as normal or abnormal separately by two musculoskeletal radiologists who were masked to the history and arthroscopic results. The surgical findings were used as the gold standard for calculating the sensitivity, specificity, and accuracy for interpreting the correct location of a labral abnormality. The sensitivity, specificity, and accuracy for the two sequences were compared with a McNemar test, and significance defined as P<0.05.Results. For observer 1, the sensitivity for labral abnormalities was 0.59 on the T2-weighted images, and 0.78 on the mid-TE images (P=0.12). The specificity was 0.54 for the T2-weighted, and 0.64 for the mid-TE images (P=0.51). The accuracy was 0.56 for the T2-weighted, and 0.71 for the mid-TE images (P=0.08). For observer 2, the sensitivity/specificity/accuracy was 0.67/0.93/0.80 for the T2-weighted, and 0.70/0.86/0.78 for the mid-TE images (all P>0.5).Conclusion. In this small study there is no statistically significant difference for demonstrating labral abnormalities between FSE T2-weighted images, and higher-resolution fat-suppressed FSE mid-TE (TE[effective]=34) images obtained with a similar acquisition time. Although there was a general trend toward higher sensitivity and accuracy with the mid

  6. 3.0T MR imaging of the ankle: Axial traction for morphological cartilage evaluation, quantitative T2 mapping and cartilage diffusion imaging-A preliminary study.

    Science.gov (United States)

    Jungmann, Pia M; Baum, Thomas; Schaeffeler, Christoph; Sauerschnig, Martin; Brucker, Peter U; Mann, Alexander; Ganter, Carl; Bieri, Oliver; Rummeny, Ernst J; Woertler, Klaus; Bauer, Jan S

    2015-08-01

    To determine the impact of axial traction during high resolution 3.0T MR imaging of the ankle on morphological assessment of articular cartilage and quantitative cartilage imaging parameters. MR images of n=25 asymptomatic ankles were acquired with and without axial traction (6kg). Coronal and sagittal T1-weighted (w) turbo spin echo (TSE) sequences with a driven equilibrium pulse and sagittal fat-saturated intermediate-w (IMfs) TSE sequences were acquired for morphological evaluation on a four-point scale (1=best, 4=worst). For quantitative assessment of cartilage degradation segmentation was performed on 2D multislice-multiecho (MSME) SE T2, steady-state free-precession (SSFP; n=8) T2 and SSFP diffusion-weighted imaging (DWI; n=8) images. Wilcoxon-tests and paired t-tests were used for statistical analysis. With axial traction, joint space width increased significantly and delineation of cartilage surfaces was rated superior (Pevaluation were smaller. Subchondral bone evaluation, motion artifacts and image quality were not significantly different between the acquisition methods (P>0.05). T2 values were lower at the tibia than at the talus (P<0.001). Reproducibility was better for images with axial traction. Axial traction increased the joint space width, allowed for better visualization of cartilage surfaces and improved compartment discrimination and reproducibility of quantitative cartilage parameters. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  7. MR imaging of the brachial plexus: comparison between 1.5-T and 3-T MR imaging: preliminary experience

    Energy Technology Data Exchange (ETDEWEB)

    Tagliafico, Alberto; Neumaier, Carlo Emanuele; Calabrese, Massimo [National Institute for Cancer Research, Department of Radiology, Genova (Italy); Succio, Giulia; Serafini, Giovanni; Ghidara, Matteo [Santa Corona Hospital, Radiology Department, Savona (Italy); Martinoli, Carlo [Universita di Genova, Radiology Department, Genova (Italy)

    2011-06-15

    To compare 1.5-T and 3-T magnetic resonance (MR) imaging of the brachial plexus. Institutional review board approval and informed consent were obtained from 30 healthy volunteers and 30 consecutive patients with brachial plexus disturbances. MR was prospectively performed with comparable sequence parameters and coils with a 1.5-T and a 3-T system. Imaging protocols at both field strengths included T1-weighted turbo spin-echo (tSE) sequences and T2-weighed turbo spin-echo (tSE) sequences with fat saturation. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) between muscle and nerve were calculated for both field strengths. The visibility of brachial plexus nerve at various anatomic levels (roots, interscalene area, costoclavicular space, and axillary level) was analyzed with a four-point grading scale by two radiologists. MR imaging diagnoses and pathological findings were also compared qualitatively. SNR and CNRs were significantly higher on 3-T MR images than on 1.5-T MR images (Friedman test) for all sequences. Nerve visibility was significantly better on 3-T MR images than on 1.5-T MR images (paired sign test). Pathological findings (n = 30/30) were seen equally well with both field strengths. MR imaging diagnoses did not differ for the 1.5- and 3-T protocols. High-quality MR images of the brachial plexus can be obtained with 3-T MR imaging by using sequences similar to those used at 1.5-T MR imaging. In patients and healthy volunteers, the visibility of nerve trunks and cords at 3-T MR imaging appears to be superior to that at 1.5-T MR imaging. (orig.)

  8. Comparison of Turbo Spin Echo and Echo Planar Imaging for intravoxel incoherent motion and diffusion tensor imaging of the kidney at 3 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Hilbert, Fabian; Wech, Tobias; Neubauer, Henning; Veldhoen, Simon; Bley, Thorsten Alexander; Koestler, Herbert [Wuerzburg Univ. (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie

    2017-10-01

    Echo Planar Imaging (EPI) is most commonly applied to acquire diffusion-weighted MR-images. EPI is able to capture an entire image in very short time, but is prone to distortions and artifacts. In diffusion-weighted EPI of the kidney severe distortions may occur due to intestinal gas. Turbo Spin Echo (TSE) is robust against distortions and artifacts, but needs more time to acquire an entire image compared to EPI. Therefore, TSE is more sensitive to motion during the readout. In this study we compare diffusion-weighted TSE and EPI of the human kidney with regard to intravoxel incoherent motion (IVIM) and diffusion tensor imaging (DTI). Images were acquired with b-values between 0 and 750 s/mm{sup 2} with TSE and EPI. Distortions were observed with the EPI readout in all volunteers, while the TSE images were virtually distortion-free. Fractional anisotropy of the diffusion tensor was significantly lower for TSE than for EPI. All other parameters of DTI and IVIM were comparable for TSE and EPI. Especially the main diffusion directions yielded by TSE and EPI were similar. The results demonstrate that TSE is a worthwhile distortion-free alternative to EPI for diffusion-weighted imaging of the kidney at 3 Tesla.

  9. Diagnostic performance of dark-blood T2-weighted CMR for evaluation of acute myocardial injury.

    Science.gov (United States)

    Srichai, Monvadi B; Lim, Ruth P; Lath, Narayan; Babb, James; Axel, Leon; Kim, Daniel

    2013-01-01

    We compared the image quality and diagnostic performance of 2 fat-suppression methods for black-blood T2-weighted fast spin-echo (FSE), which are as follows: (a) short T1 inversion recovery (STIR; FSE-STIR) and (b) spectral adiabatic inversion recovery (SPAIR; FSE-SPAIR), for detection of acute myocardial injury. Edema-sensitive T2-weighted FSE cardiac magnetic resonance (CMR) imaging is useful in detecting acute myocardial injury but may experience reduced myocardial signal and signal dropout. The SPAIR pulse aims to eliminate artifacts associated with the STIR pulse. A total of 65 consecutive patients referred for CMR evaluation of myocardial structure and function underwent FSE-STIR and FSE-SPAIR, in addition to cine and late gadolinium enhancement (LGE) CMR. T2-weighted FSE images were independently evaluated by 2 readers for image quality and artifacts (Likert scale of 1-5; best-worst) and presence of increased myocardial signal suggestive of edema. In addition, clinical CMR interpretation, incorporating all CMR sequences available, was recorded for comparison. Diagnostic performance of each T2-weighted sequence was measured using recent (T2, and wall motion. There was a statistically significant difference in sensitivity between the clinical interpretation and each of the T2-weighted sequences but not between each T2-weighted sequence. Although FSE-SPAIR demonstrated significantly improved image quality and decreased artifacts, isolated interpretations of each T2-weighted technique demonstrated high specificity but overall low sensitivity for the detection of myocardial injury, with no difference in accuracy between the techniques. However, real-world interpretation in combination with cine and LGE CMR methods significantly improves the overall sensitivity and diagnostic performance.

  10. Separate Turbo Code and Single Turbo Code Adaptive OFDM Transmissions

    Directory of Open Access Journals (Sweden)

    Lei Ye

    2009-01-01

    Full Text Available This paper discusses the application of adaptive modulation and adaptive rate turbo coding to orthogonal frequency-division multiplexing (OFDM, to increase throughput on the time and frequency selective channel. The adaptive turbo code scheme is based on a subband adaptive method, and compares two adaptive systems: a conventional approach where a separate turbo code is used for each subband, and a single turbo code adaptive system which uses a single turbo code over all subbands. Five modulation schemes (BPSK, QPSK, 8AMPM, 16QAM, and 64QAM are employed and turbo code rates considered are 1/2 and 1/3. The performances of both systems with high (10−2 and low (10−4 BER targets are compared. Simulation results for throughput and BER show that the single turbo code adaptive system provides a significant improvement.

  11. T2-weighted four dimensional magnetic resonance imaging with result-driven phase sorting

    International Nuclear Information System (INIS)

    Liu, Yilin; Yin, Fang-Fang; Cai, Jing; Czito, Brian G.; Bashir, Mustafa R.

    2015-01-01

    Purpose: T2-weighted MRI provides excellent tumor-to-tissue contrast for target volume delineation in radiation therapy treatment planning. This study aims at developing a novel T2-weighted retrospective four dimensional magnetic resonance imaging (4D-MRI) phase sorting technique for imaging organ/tumor respiratory motion. Methods: A 2D fast T2-weighted half-Fourier acquisition single-shot turbo spin-echo MR sequence was used for image acquisition of 4D-MRI, with a frame rate of 2–3 frames/s. Respiratory motion was measured using an external breathing monitoring device. A phase sorting method was developed to sort the images by their corresponding respiratory phases. Besides, a result-driven strategy was applied to effectively utilize redundant images in the case when multiple images were allocated to a bin. This strategy, selecting the image with minimal amplitude error, will generate the most representative 4D-MRI. Since we are using a different image acquisition mode for 4D imaging (the sequential image acquisition scheme) with the conventionally used cine or helical image acquisition scheme, the 4D dataset sufficient condition was not obviously and directly predictable. An important challenge of the proposed technique was to determine the number of repeated scans (N_R) required to obtain sufficient phase information at each slice position. To tackle this challenge, the authors first conducted computer simulations using real-time position management respiratory signals of the 29 cancer patients under an IRB-approved retrospective study to derive the relationships between N_R and the following factors: number of slices (N_S), number of 4D-MRI respiratory bins (N_B), and starting phase at image acquisition (P_0). To validate the authors’ technique, 4D-MRI acquisition and reconstruction were simulated on a 4D digital extended cardiac-torso (XCAT) human phantom using simulation derived parameters. Twelve healthy volunteers were involved in an IRB-approved study

  12. 3D hybrid profile order technique in a single breath-hold 3D T2-weighted fast spin-echo sequence: Usefulness in diagnosis of small liver lesions.

    Science.gov (United States)

    Hirata, Kenichiro; Nakaura, Takeshi; Okuaki, Tomoyuki; Tsuda, Noriko; Taguchi, Narumi; Oda, Seitaro; Utsunomiya, Daisuke; Yamashita, Yasuyuki

    2018-01-01

    We compared the efficacy of three-dimensional (3D) isotropic T2-weighted fast spin-echo imaging using a 3D hybrid profile order technique with a single-breath-hold (3D-Hybrid BH) with a two-dimensional (2D) T2-weighted fast spin-echo conventional respiratory-gated (2D-Conventional RG) technique for visualising small liver lesions. This study was approved by our institutional review board. The requirement to obtain written informed consent was waived. Fifty patients with small (≤15mm) hepatocellular carcinomas (HCC) (n=26), or benign cysts (n=24), had undergone hepatic MRI including both 2D-Conventional RG and 3D-Hybrid BH. We calculated the signal-to-noise ratio (SNR) and tumour-to-liver contrast (TLC). The diagnostic performance of the two protocols was analysed. The image acquisition time was 89% shorter with the 3D-Hybrid BH than with 2D-Conventional RG. There was no significant difference in the SNR between the two protocols. The area under the curve (AUC) of the TLC was significantly higher on 3D-Hybrid BH than on 2D-Conventional RG. The 3D-Hybrid BH sequence significantly improved diagnostic performance for small liver lesions with a shorter image acquisition time without sacrificing accuracy. Copyright © 2017. Published by Elsevier B.V.

  13. 3D Fast Spin Echo T2-weighted Contrast for Imaging the Female Cervix

    Science.gov (United States)

    Vargas Sanchez, Andrea Fernanda

    Magnetic Resonance Imaging (MRI) with T2-weighted contrast is the preferred modality for treatment planning and monitoring of cervical cancer. Current clinical protocols image the volume of interest multiple times with two dimensional (2D) T2-weighted MRI techniques. It is of interest to replace these multiple 2D acquisitions with a single three dimensional (3D) MRI acquisition to save time. However, at present the image contrast of standard 3D MRI does not distinguish cervical healthy tissue from cancerous tissue. The purpose of this thesis is to better understand the underlying factors that govern the contrast of 3D MRI and exploit this understanding via sequence modifications to improve the contrast. Numerical simulations are developed to predict observed contrast alterations and to propose an improvement. Improvements of image contrast are shown in simulation and with healthy volunteers. Reported results are only preliminary but a promising start to establish definitively 3D MRI for cervical cancer applications.

  14. Superparamagnetic iron oxide enhanced MR imaging: influence of hepatic dysfunction in cirrhotic patients

    International Nuclear Information System (INIS)

    Kwak, Hyo Sung; Lee, Jeong Min; Kim, Chong Soo; Ym, Seong Hee; Han, Hyun Young

    2000-01-01

    To determine the influence of liver dysfunction on the detection of focal hepatic nodules, and investigate the loss of signal intensity of hepatic parenchyma occurring after superparamagnetic iron oxide (SPIO)-induced contrast enhancement in patients with liver cirrhosis. In 68 patients with liver cirrhosis, we evaluated MR images before and after the administration of SPIO. /clinical information and laboratory data indicated that the liver was normal in ten patients (nine hemangiomas and one hepatic cyst), while Child's A was diagnosed in 25 cases (22 of which were hepatocellular carcinoma (HCCs)),Child's B in 15 (11 HCCs), and Child's C in 18 (10 HCCs).Before and after SPIO administration, conventional T2-weighted spin-echo, respiratory-triggered T2-weighted turbo spin-echo, and breathhold T2-weighted turbo spin-echo images were obtained. After the administration of SPIO, degrees of lever dysfunction and laboratory data were correlated with reductions in signal intensity of the liver, and in addition, the state of hepatic dysfunction was correlated with inhomogeneous parenchymal change and lesion conspicuity. After the administration of SPIO, percentage signal loss in liver parenchyma was significantly higher on conventional T2-weighted spin-echo images than on T2-weighted turbo spin-echo and breathhold T2-weighted turbo spin-echo (p less than 0.05). There was significant correlation between degree of liver dysfunction and of signal loss (p less than ).05), while percentage signal loss of the liver was lower in the Child's C group than in the other three. In addition, there was close correlation between percentage signal loss and laboratory data such as albumin and total bilirubin levels, and prothrombin time (p less than 0.05). Qualitative analysis showed that inhomogeneous enhancement due to fibrous septa and a regenerative nodule occurred more often in the Child's B and Child's C group than in the normal and Child's A group (p less than 0.0001). In terms of

  15. SPAMM, cine phase contrast imaging and fast spin-echo T2-weighted imaging in the study of intracranial cerebrospinal fluid (CSF) flow

    International Nuclear Information System (INIS)

    Connor, S.E.J.; O'Gorman, R.; Summers, P.; Simmons, A.; Moore, E.M.; Chandler, C.; Jarosz, J.M.

    2001-01-01

    AIM: To compare the qualitative assessment of cerebrospinal fluid (CSF) flow using a SPAMM (spatial modulation of magnetization) technique with cine phase contrast images (cine PC) and fast spin echo (FSE) T2-weighted images. MATERIALS AND METHODS: SPAMM, PC and T2-weighted sequences were performed on 22 occasions in 19 patients. Eleven of the studies were performed following a neuroendoscopic third ventriculostomy (NTV), and in these cases, the success of the NTV was determined by clinical follow-up. Two observers used consensus to grade the presence of CSF flow at nine different sites for each study. RESULTS: At 14 of the 178 matched sites, which could be assessed by both SPAMM and cine PC, SPAMM CSF flow grade was higher than that of cine PC. At a further 14/178 matched sites, the cine PC grade was higher than that of SPAMM. There was definite CSF flow at 113/182 (62%) of all the cine PC sites assessed, and 110/181 (61%) of all SPAMM sites assessed whilst 108/198 (54%) of FSE T2-weighted image sites demonstrated flow voids. Cine PC grades were higher than SPAMM at the cerebral aqueduct (P < 0.05, Wilcoxon sign rank test). Definite CSF flow within the anterior third ventricle was present in 4/5 (SPAMM) and 3/5 (cine PC) successful NTVs, 0/2 (SPAMM and cine PC) unsuccessful NTVs and 1/10 (SPAMM and cine PC) patients without NTV. CONCLUSION: SPAMM provides a comparable assessment of intracranial CSF flow to that of cine phase contrast imaging at all CSF sites except the cerebral aqueduct. Connor, S.E.J. et al. (2001)

  16. Paradoxical signal pattern of mediastinal cysts on T2-weighted MR imaging: phantom and clinical study

    Energy Technology Data Exchange (ETDEWEB)

    Ueda, Ken, E-mail: k-ueda@radiol.med.osaka-u.ac.jp [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Yanagawa, Masahiro [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Ueguchi, Takashi [Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Satoh, Yukihisa; Kawai, Misa; Gyobu, Tomoko; Sumikawa, Hiromitsu; Honda, Osamu; Tomiyama, Noriyuki [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan)

    2014-06-15

    Purpose: To evaluate the intracystic MRI (magnetic resonance imaging) signal intensity of mediastinal cystic masses on T2-weighted images. Materials and methods: A phantom study was performed to evaluate the signal intensity of a mediastinal cystic mass phantom (rubber balloon containing water) adjacent to a cardiac phantom pulsing at the rate of 60/min. T2-weighted images (sequence, fast spin echo [FSE] and single shot fast spin echo [SSFSE]) were acquired for the mediastinal cystic mass phantom. Further, a clinical study was performed in 33 patients (16 men, 17 women; age range, 19-85 years; mean, 65years) with thymic cysts or pericardial cysts. In all patients, T2-weighted images (FSE and SSFSE) were acquired. The signal intensity of cystic lesion was evaluated and was compared with that of muscle. A region of interest (ROI) was positioned on the standard MR console, and signal intensity of the cystic mass (cSI), that of the muscle (mSI), and the rate of absolute value of cSI–mSI to standard deviation (SD) of background noise (|cSI–mSI|/SD = CNR [contrast-to-noise ratio]) were measured. Results: The phantom study demonstrated that the rate phantom-ROI/saline-ROI was higher in SSFSE (0.36) than in FSE (0.19). In clinical cases, the degree of the signal intensity was higher in SSFSE than in FSE. The CNR was significantly higher in SSFSE (mean ± standard deviation, 111.0 ± 47.6) than in FSE (72.8 ± 36.6) (p < 0.001, Wilcoxon signed-rank test). Conclusions: Anterior mediastinal cysts often show lower signal intensity than the original signal intensity of water on T2-weighted images. SSFSE sequence reduces this paradoxical signal pattern on T2-weighted images, which may otherwise cause misinterpretation when assessing cystic lesions.

  17. Paradoxical signal pattern of mediastinal cysts on T2-weighted MR imaging: phantom and clinical study

    International Nuclear Information System (INIS)

    Ueda, Ken; Yanagawa, Masahiro; Ueguchi, Takashi; Satoh, Yukihisa; Kawai, Misa; Gyobu, Tomoko; Sumikawa, Hiromitsu; Honda, Osamu; Tomiyama, Noriyuki

    2014-01-01

    Purpose: To evaluate the intracystic MRI (magnetic resonance imaging) signal intensity of mediastinal cystic masses on T2-weighted images. Materials and methods: A phantom study was performed to evaluate the signal intensity of a mediastinal cystic mass phantom (rubber balloon containing water) adjacent to a cardiac phantom pulsing at the rate of 60/min. T2-weighted images (sequence, fast spin echo [FSE] and single shot fast spin echo [SSFSE]) were acquired for the mediastinal cystic mass phantom. Further, a clinical study was performed in 33 patients (16 men, 17 women; age range, 19-85 years; mean, 65years) with thymic cysts or pericardial cysts. In all patients, T2-weighted images (FSE and SSFSE) were acquired. The signal intensity of cystic lesion was evaluated and was compared with that of muscle. A region of interest (ROI) was positioned on the standard MR console, and signal intensity of the cystic mass (cSI), that of the muscle (mSI), and the rate of absolute value of cSI–mSI to standard deviation (SD) of background noise (|cSI–mSI|/SD = CNR [contrast-to-noise ratio]) were measured. Results: The phantom study demonstrated that the rate phantom-ROI/saline-ROI was higher in SSFSE (0.36) than in FSE (0.19). In clinical cases, the degree of the signal intensity was higher in SSFSE than in FSE. The CNR was significantly higher in SSFSE (mean ± standard deviation, 111.0 ± 47.6) than in FSE (72.8 ± 36.6) (p < 0.001, Wilcoxon signed-rank test). Conclusions: Anterior mediastinal cysts often show lower signal intensity than the original signal intensity of water on T2-weighted images. SSFSE sequence reduces this paradoxical signal pattern on T2-weighted images, which may otherwise cause misinterpretation when assessing cystic lesions

  18. Magnetic resonance imaging of anterior cruciate ligament of the knee: a comparison of four sequences; Valoracion del ligamento cruzado anterior de la rodilla con RM: comparacion de cuatro secuencias

    Energy Technology Data Exchange (ETDEWEB)

    Casillas, C.; Marti-Bonmati, L.; Molla, E.; Ferrer, P.; Dosda, R. [Clinical Quiron-ATQ. Valencia (Spain)

    1999-07-01

    To compare the diagnostic efficacy of the four magnetic resonance imaging (MRI) sequences that compose the standard protocol for the study of the knee in our center when employed in the examination of anterior cruciate ligament (ACL). A prospective study was carried out based on MRI findings in the knees of 326 consecutive patients. Sagittal [proton density (PD{sub w}eighted turbo-spin-echo and T2*-weighted gradient echo], coronal (PD-weighted turbo-spin-echo with fat suppression) and transverse (T2*-weighted gradient echo with magnetization transfer) images were evaluated. Each sequence was analyzed independently by two radiologists, while another two assessed all the sequences together with the clinical findings. Four categories were established: normal ACL, partially torn, completely torn and synovialized. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) with respect to the definitive diagnosis were calculated for each sequence. The statistical analysis of the findings for each category was done using the chi-squared test and the Kappa test was employed to assess the degree of agreement. According to the final diagnosis, 263 ACL were normal, 29 were partially torn, 33 were completely torn and there was 1 case of synovialization associated with a completely torn ACL. The relationship between the analysis of the ACL according to each sequence and the definitive diagnosis was very significant (p<0.001) and the agreement was excellent. All the sequences presented similar levels of diagnostic precision. The coronal sequence had least number of diagnostic errors (2.1%). The combinations of imaging techniques that resulted in the lowest error rate with respect to the definitive diagnosis were coronal PD-weighted turbo-spin-echo with fat suppression and sagittal PD-weighted turbo-spin-echo. Coronal images are highly precise in the evaluation of ACL. Sagittal sequences are the most valid for diagnosis of torn ACL

  19. “Hot cross bun” sign in multiple system atrophy with predominant cerebellar ataxia: A comparison between proton density-weighted imaging and T2-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kasahara, Seiko, E-mail: nuun077@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Miki, Yukio, E-mail: yukio.miki@med.osaka-cu.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Department of Radiology, Osaka City University Graduate School of Medicine, 1-4-3 Asahi-machi, Abeno-ku, Osaka 545–8585 (Japan); Kanagaki, Mitsunori, E-mail: mitsuk@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Kondo, Takayuki, E-mail: kondotak@kuhp.kyoto-u.ac.jp [Department of Neurology, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Yamamoto, Akira, E-mail: yakira@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Morimoto, Emiko, E-mail: foresta@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Okada, Tomohisa, E-mail: tomokada@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Ito, Hidefumi, E-mail: itohid@kuhp.kyoto-u.ac.jp [Department of Neurology, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Takahashi, Ryosuke, E-mail: ryosuket@kuhp.kyoto-u.ac.jp [Department of Neurology, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); and others

    2012-10-15

    Objective: To investigate whether proton density-weighted imaging can detect the “hot cross bun” sign in the pons in multiple system atrophy with predominant cerebellar ataxia significantly better than T2-weighted imaging at 3 T. Methods: Sixteen consecutive patients with multiple system atrophy with predominant cerebellar ataxia according to the Consensus Criteria were reviewed. Axial unenhanced proton density-weighted imaging and T2-weighted imaging were obtained using a dual-echo fast spin-echo sequence at 3 T. Two neuroradiologists independently evaluated visualisation of the abnormal pontine signal using a 4-point visual grade from Grade 0 (no “hot cross bun” sign) to Grade 3 (prominent “hot cross bun” sign on two or more sequential slices). Differences in grade between proton density-weighted imaging and T2-weighted imaging were statistically analysed using the Wilcoxon signed-rank test. Results: In 11 patients (69%), a higher grade was given for proton density-weighted imaging than T2-weighted imaging. In 1 patient (6%), grades were the same (Grade 3) on both images. In the remaining 4 patients (25%), signal abnormalities were not detected on either image (Grade 0). The “hot cross bun” sign was thus observed significantly better on proton density-weighted imaging than on T2-weighted imaging (P = 0.001). Conclusions: The “hot cross bun” sign considered diagnostic for multiple system atrophy with predominant cerebellar ataxia is significantly better visualised on proton density-weighted imaging than on T2-weighted imaging at 3 T.

  20. Gd-EOB-DTPA-Enhanced MR Imaging of the Liver: The Effect on T2 Relaxation Times and Apparent Diffusion Coefficient (ADC)

    International Nuclear Information System (INIS)

    Cieszanowski, Andrzej; Podgórska, Joanna; Rosiak, Grzegorz; Maj, Edyta; Grudziński, Ireneusz P.; Kaczyński, Bartosz; Szeszkowski, Wojciech; Milczarek, Krzysztof; Rowiński, Olgierd

    2016-01-01

    To investigate the effect of gadoxetic acid disodium (Gd-EOB-DTPA) on T2 relaxation times and apparent diffusion coefficient (ADC) values of the liver and focal liver lesions on a 1.5-T system. Magnetic resonance (MR) studies of 50 patients with 35 liver lesions were retrospectively analyzed. All examinations were performed at 1.5T and included T2-weighted turbo spin-echo (TSE) and diffusion-weighted (DW) images acquired before and after intravenous administration of Gd-EOB-DTPA. To assess the effect of this hepatobiliary contrast agent on T2-weighted TSE images and DW images T2 relaxation times and ADC values of the liver and FLLs were calculated and compared pre- and post-injection. The mean T2 relaxation times of the liver and focal hepatic lesions were lower on enhanced than on unenhanced T2-weighted TSE images (decrease of 2.7% and 3.6% respectively), although these differences were not statistically significant. The mean ADC values of the liver showed statistically significant decrease (of 4.6%) on contrast-enhanced DW images, compared to unenhanced images (P>0.05). The mean ADC value of liver lesions was lower on enhanced than on unenhanced DW images, but this difference (of 2.9%) did not reach statistical significance. The mean T2 relaxation times of the liver and focal liver lesions as well as the mean ADC values of liver lesions were not significantly different before and after administration of Gd-EOB-DTPA. Therefore, acquisition of T2-weighted and DW images between the dynamic contrast-enhanced examination and hepatobiliary phase is feasible and time-saving

  1. T2 relaxation time is related to liver fibrosis severity

    Science.gov (United States)

    Siqueira, Luiz; Uppal, Ritika; Alford, Jamu; Fuchs, Bryan C.; Yamada, Suguru; Tanabe, Kenneth; Chung, Raymond T.; Lauwers, Gregory; Chew, Michael L.; Boland, Giles W.; Sahani, Duhyant V.; Vangel, Mark; Hahn, Peter F.; Caravan, Peter

    2016-01-01

    echo T2 weighted data. Statistical comparison was performed using ANOVA. Results (I) Histopathologic evaluation of both rat and human livers demonstrated no evidence of steatosis or hemochromatosis There was a monotonic increase in mean T2 value with increasing degree of fibrosis (control 65.4±2.9 ms, n=6 patients); mild (Ishak 1–2) 66.7±1.9 ms (n=30); moderate (Ishak 3–4) 71.6±1.7 ms (n=26); severe (Ishak 5–6) 72.4±1.4 ms (n=61); with relatively low standard error (~2.9 ms). There was a statistically significant difference between degrees of mild (Ishak fibrosis (Ishak >4) (P=0.03) based on logistic regression of T2 and Ishak, which became insignificant (P=0.07) when using inflammatory markers as covariates. Expanding on this model using ordinal logistic regression, there was significance amongst all 4 groups comparing T2 to Ishak (P=0.01), with significance using inflammation as a covariate (P=0.03) and approaching statistical significance amongst all groups by ANOVA (P=0.07); (II) there was a monotonic increase in T2 and statistical significance (ANOVA Pliver (e.g., 20–100 ms), demonstrated no statistical difference between two point fits on turbo spin echo (TSE) data and multi-echo CPMG data (P=0.9). Conclusions The finding of increased T2 with liver fibrosis may relate to inflammation that may be an alternative or adjunct to other noninvasive MR imaging based approaches for assessing liver fibrosis. PMID:27190762

  2. T2*-weighted image/T2-weighted image fusion in postimplant dosimetry of prostate brachytherapy

    International Nuclear Information System (INIS)

    Katayama, Norihisa; Takemoto, Mitsuhiro; Yoshio, Kotaro

    2011-01-01

    Computed tomography (CT)/magnetic resonance imaging (MRI) fusion is considered to be the best method for postimplant dosimetry of permanent prostate brachytherapy; however, it is inconvenient and costly. In T2 * -weighted image (T2 * -WI), seeds can be easily detected without the use of an intravenous contrast material. We present a novel method for postimplant dosimetry using T2 * -WI/T2-weighted image (T2-WI) fusion. We compared the outcomes of T2 * -WI/T2-WI fusion-based and CT/T2-WI fusion-based postimplant dosimetry. Between April 2008 and July 2009, 50 consecutive prostate cancer patients underwent brachytherapy. All the patients were treated with 144 Gy of brachytherapy alone. Dose-volume histogram (DVH) parameters (prostate D90, prostate V100, prostate V150, urethral D10, and rectal D2cc) were prospectively compared between T2 * -WI/T2-WI fusion-based and CT/T2-WI fusion-based dosimetry. All the DVH parameters estimated by T2 * -WI/T2-WI fusion-based dosimetry strongly correlated to those estimated by CT/T2-WI fusion-based dosimetry (0.77≤ R ≤0.91). No significant difference was observed in these parameters between the two methods, except for prostate V150 (p=0.04). These results show that T2 * -WI/T2-WI fusion-based dosimetry is comparable or superior to MRI-based dosimetry as previously reported, because no intravenous contrast material is required. For some patients, rather large differences were observed in the value between the 2 methods. We thought these large differences were a result of seed miscounts in T2 * -WI and shifts in fusion. Improving the image quality of T2 * -WI and the image acquisition speed of T2 * -WI and T2-WI may decrease seed miscounts and fusion shifts. Therefore, in the future, T2 * -WI/T2-WI fusion may be more useful for postimplant dosimetry of prostate brachytherapy. (author)

  3. Partial flip angle spin-echo imaging to obtain T1 weighted images with electrocardiographic gating

    International Nuclear Information System (INIS)

    Kawamitsu, Hideaki; Sugimura, Kazuro; Kasai, Toshifumi; Kimino, Katsuji

    1993-01-01

    ECG-gated spin-echo (SE) imaging can reduce physiologic motion artifact. However, it does not provide strong T 1 -weighted images, because the repetition time (TR) depends on heart rate (HR). For odd-echo SE imaging, T 1 contrast can be maximized by using a smaller flip angle (FA) of initial excitation RF pulses. We investigated the usefulness of partial FA SE imaging in order to obtain more T 1 -dependent contrast with ECG gating and determined the optimal FA at each heart rate. In computer simulation and phantom study, the predicted image contrast and signal-to-noise ratio (SNR) obtained for each FA (0∼180deg) and each HR (55∼90 beats per minute (bpm)) were compared with those obtained with conventional T 1 -weighted SE imaging (TR=500 ms, TE=20 ms, FA=90deg). The optimal FA was decreased by reducing HR. The FA needed to obtain T 1 -dependent contrast identical to that with T 1 -weighted SE imaging was 43deg at a HR of 65 bpm, 53deg at 70 bpm, 60deg at 75 bpm. This predicted FA were in excellent agreement with that obtained with clinical evaluation. The predicted SNR was decreased by reducing FA. The SNR of partial FA SE imaging at HR of 65 bpm (FA=43deg) was 80% of that with conventional T 1 -weighted SE imaging. However, this imaging method presented no marked clinical problem. ECG-gated partial FA SE imaging provides better T 1 -dependent contrast than conventional ECG-gated SE imaging, especially for Gd-DTPA enhanced imaging. (author)

  4. Magnetic resonance imaging of anterior cruciate ligament of the knee: a comparison of four sequences

    International Nuclear Information System (INIS)

    Casillas, C.; Marti-Bonmati, L.; Molla, E.; Ferrer, P.; Dosda, R.

    1999-01-01

    To compare the diagnostic efficacy of the four magnetic resonance imaging (MRI) sequences that compose the standard protocol for the study of the knee in our center when employed in the examination of anterior cruciate ligament (ACL). A prospective study was carried out based on MRI findings in the knees of 326 consecutive patients. Sagittal [proton density (PD w eighted turbo-spin-echo and T2*-weighted gradient echo], coronal (PD-weighted turbo-spin-echo with fat suppression) and transverse (T2*-weighted gradient echo with magnetization transfer) images were evaluated. Each sequence was analyzed independently by two radiologists, while another two assessed all the sequences together with the clinical findings. Four categories were established: normal ACL, partially torn, completely torn and synovialized. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) with respect to the definitive diagnosis were calculated for each sequence. The statistical analysis of the findings for each category was done using the chi-squared test and the Kappa test was employed to assess the degree of agreement. According to the final diagnosis, 263 ACL were normal, 29 were partially torn, 33 were completely torn and there was 1 case of synovialization associated with a completely torn ACL. The relationship between the analysis of the ACL according to each sequence and the definitive diagnosis was very significant (p<0.001) and the agreement was excellent. All the sequences presented similar levels of diagnostic precision. The coronal sequence had least number of diagnostic errors (2.1%). The combinations of imaging techniques that resulted in the lowest error rate with respect to the definitive diagnosis were coronal PD-weighted turbo-spin-echo with fat suppression and sagittal PD-weighted turbo-spin-echo. Coronal images are highly precise in the evaluation of ACL. Sagittal sequences are the most valid for diagnosis of torn ACL. Transverse

  5. MR of normal pancreas : comparison of five pulse sequences and enhancing patterns on dynamic imaging

    International Nuclear Information System (INIS)

    Jang, Hyun Jung; Kim, Tae Kyoung; Hong, Sung Hwan; Han, Joon Koo; Choi, Byung Ihn

    1997-01-01

    To compare T1-weighted FLASH and turbo spin echo (SE) T2-weighted sequences with conventional T1- and T2-weighted sequences in imaging normal pancreas and to describe the enhancing patterns on dynamic MR imging. Forty-four patients with presumed hepatic hemangiomas were studied at 1.0T or 1.5T by using conventional SE sequences (T1-weighted, T2-weighted, and heavily T2-weighted), turbo-SE T2-weighted sequences, and breath-hold T1-weighted FLASH sequences acquired before, immediately on, and at 1, 2, 3, and 5 or 10 minutes after injection of a bolus of gadopentetate dimeglumine. No patients had either a history or its clinical features of pancreatic disease. Images were quantitatively analyzed for signal-difference-to noise ratios (SD/Ns) between the pancreas and peripancreatic fat. Percentage enhancement of the pancreas was measured on each dynamic MR image. Conspicuity of the pancreatic border was qualitatively evaluated according to a consensus, reached by three radiologists. Turbo-SE T2-weighted images had a significantly higher SD/N ratio (p<0.001) and better conspicuity of the pancreatic border (p<0.001) than SE T2- and heavily T2-weighted images;T1-weighted SE images had a significantly higher SD/N ratio than T1-weighted FLASH images (p<0.001), but there was no significant difference between tham in qualitative analysis (p=0.346). Percentage enhancement immediately on and at 1, 2, 3, 5, and 10 minutes after administration of contrast material was 39.9%, 44.5%, 42.9%, 40.8%, 36.3%, 29.9%, respectively, with peak enhancement at 1 minute. In MR imaging of normal pancreas, turbo-SE T2-weighted imaging is superior to SE T2- and heavily T2- weighted imaging, and SE T1-weighted imaging is superior to T1-weighted FLASH imaging. On serial gadolinium-enhanced FLASH imaging, normal pancreas shows peak enhancement at 1 minute

  6. Visualization of cranial nerves I-XII: value of 3D CISS and T2-weighted FSE sequences

    Energy Technology Data Exchange (ETDEWEB)

    Yousry, I.; Camelio, S.; Wiesmann, M.; Brueckmann, H.; Yousry, T.A. [Department of Neuroradiology, Klinikum Grosshadern, Ludwig-Maximilians University, Marchioninistrasse 15, D-81377 Munich (Germany); Schmid, U.D. [Neurosurgical Unit, Klinik im Park, 8000 Zurich (Switzerland); Horsfield, M.A. [Department of Medical Physics, University of Leicester, Leicester LE1 5WW (United Kingdom)

    2000-07-01

    The aim of this study was to evaluate the sensitivity of the three-dimensional constructive interference of steady state (3D CISS) sequence (slice thickness 0.7 mm) and that of the T2-weighted fast spin echo (T2-weighted FSE) sequence (slice thickness 3 mm) for the visualization of all cranial nerves in their cisternal course. Twenty healthy volunteers were examined using the T2-weighted FSE and the 3D CISS sequences. Three observers evaluated independently the cranial nerves NI-NXII in their cisternal course. The rates for successful visualization of each nerve for 3D CISS (and for T2-weighted FSE in parentheses) were as follows: NI, NII, NV, NVII, NVIII 40 of 40 (40 of 40), NIII 40 of 40 (18 of 40), NIV 19 of 40 (3 of 40), NVI 39 of 40 (5 of 40), NIX, X, XI 40 of 40 (29 of 40), and NXII 40 of 40 (4 of 40). Most of the cranial nerves can be reliably assessed when using the 3D CISS and the T2-weighted FSE sequences. Increasing the spatial resolution when using the 3D CISS sequence increases the reliability of the identification of the cranial nerves NIII-NXII. (orig.)

  7. Visualization of cranial nerves I-XII: value of 3D CISS and T2-weighted FSE sequences

    International Nuclear Information System (INIS)

    Yousry, I.; Camelio, S.; Wiesmann, M.; Brueckmann, H.; Yousry, T.A.; Schmid, U.D.; Horsfield, M.A.

    2000-01-01

    The aim of this study was to evaluate the sensitivity of the three-dimensional constructive interference of steady state (3D CISS) sequence (slice thickness 0.7 mm) and that of the T2-weighted fast spin echo (T2-weighted FSE) sequence (slice thickness 3 mm) for the visualization of all cranial nerves in their cisternal course. Twenty healthy volunteers were examined using the T2-weighted FSE and the 3D CISS sequences. Three observers evaluated independently the cranial nerves NI-NXII in their cisternal course. The rates for successful visualization of each nerve for 3D CISS (and for T2-weighted FSE in parentheses) were as follows: NI, NII, NV, NVII, NVIII 40 of 40 (40 of 40), NIII 40 of 40 (18 of 40), NIV 19 of 40 (3 of 40), NVI 39 of 40 (5 of 40), NIX, X, XI 40 of 40 (29 of 40), and NXII 40 of 40 (4 of 40). Most of the cranial nerves can be reliably assessed when using the 3D CISS and the T2-weighted FSE sequences. Increasing the spatial resolution when using the 3D CISS sequence increases the reliability of the identification of the cranial nerves NIII-NXII. (orig.)

  8. Conduction-band valley spin splitting in single-layer H-T l2O

    Science.gov (United States)

    Ma, Yandong; Kou, Liangzhi; Du, Aijun; Huang, Baibiao; Dai, Ying; Heine, Thomas

    2018-02-01

    Despite numerous studies, coupled spin and valley physics is currently limited to two-dimensional (2D) transition-metal dichalcogenides (TMDCs). Here, we predict an exceptional 2D valleytronic material associated with the spin-valley coupling phenomena beyond 2D TMDCs—single-layer (SL) H-T l2O . It displays large valley spin splitting (VSS), significantly larger than that of 2D TMDCs, and a finite band gap, which are both critically attractive for the integration of valleytronics and spintronics. More importantly, in sharp contrast to all the experimentally confirmed 2D valleytronic materials, where the strong valence-band VSS (0.15-0.46 eV) supports the spin-valley coupling, the VSS in SL H-T l2O is pronounced in its conduction band (0.61 eV), but negligibly small in its valence band (21 meV), thus opening a way for manipulating the coupled spin and valley physics. Moreover, SL H-T l2O possesses extremely high carrier mobility, as large as 9.8 ×103c m2V-1s-1 .

  9. Fat-suppressed MRI of musculoskeletal infection: fast T2-weighted techniques versus gadolinium-enhanced T1-weighted images

    International Nuclear Information System (INIS)

    Miller, T.T.; Randolph, D.A. Jr.; Staron, R.B.; Feldman, F.; Cushin, S.

    1997-01-01

    Purpose. To investigate gadolinium's role in imaging musculoskeletal infection by comparing the conspicuity and extent of inflammatory changes demonstrated on gadolinium-enhanced fat-suppressed T1-weighted images versus fat-suppressed fast T2-weighted sequences. Design. Eighteen patients with infection were imaged in a 1.5-T unit, using frequency-selective and/or inversion recovery fat-suppressed fast T2-weighted images (T2WI) and gadolinium-enhanced frequency-selective fat-suppressed T1-weighted images (T1WI). Thirty-four imaging planes with both a fat-suppressed gadolinium-enhanced T1-weighted sequence and a fat-suppressed T2-weighted sequence were obtained. Comparison of the extent and conspicuity of signal intensity changes was made for both bone and soft tissue in each plane. Results. In bone, inflammatory change was equal in extent and conspicuity on fat-suppressed T2WI and fat-suppressed T1WI with gadolinium in 19 planes, more extensive or conspicuous on T2WI in three planes, and less so on T2WI in two planes. Marrow was normal on all three sequences in 10 cases. In soft tissue, inflammatory change was seen equally well in 20 instances, more extensively or conspicuously on the T2WI in 11 instances, and less so on T2WI in 2 instances. One case had no soft tissue involvement on any of the sequences. Five abscesses and three joint effusions were present, all more conspicuously delineated from surrounding inflammatory change on the fat-saturated T1WI with gadolinium. The average imaging time for the fat-saturated T1WI with gadolinium was 6.75 min, while that of the T2-weighted sequences was 5.75 min. Conclusion. Routine use of gadolinium is not warranted. Instead, gadolinium should be reserved for clinically suspected infection in or around a joint, and in cases refractory to medical or surgical treatment due to possible abscess formation. (orig.)

  10. T2 image contrast evaluation using three dimension sampling perfection with application optimized contrasts using different flip angle evolution (3D-SPACE)

    International Nuclear Information System (INIS)

    Yamazaki, Ryo; Hiura, Yukikazu; Tsuji, Akio; Nishiki, Shigeo; Uchikoshi, Masato

    2011-01-01

    Sampling perfection with application optimized contrasts using different flip angle evolution (3D-SPACE) sequence enables one to decrease specific absorption rate (SAR) by using variable flip angle refocusing pulse. Therefore, it is expected that the contrast obtained with 3D-SPACE sequences is different from that of spin echo (SE) images and turbo spin echo (TSE) images. The purpose of this study was to evaluate the characteristics of the signal intensity and central nervous system (CNS) image contrast in T 2 weighted 3D-SPACE. Using 3 different sequences (SE, 3D-TSE and 3D-SPACE) with repetition time (TR)/ echo time (TE)=3500/70, 90 and 115 ms, we obtained T 2 weighted magnetic resonance (MR) images of inhouse phantom and five healthy volunteers' brain. Signal intensity of the phantom which contains various T 1 and T 2 value was evaluated. Tissue contrasts of white/gray matter, cerebrospinal fluid (CSF)/subcutaneous fat and gray matter/subcutaneous fat were evaluated for a clinical image study. The phantom study showed that signal intensity in 3D-SPACE significantly decreased under a T 1 value of 250 ms. It was markedly decreased in comparison to other sequences, as effective echo time (TE) was extended. White/gray matter contrast of 3D-SPACE was the highest in all sequences. On the other hand, CSF/fat and gray matter/fat contrast of 3D-SPACE was higher than TSE but lower than SE. CNS image contrasts of 3D-SPACE were comparable to that of SE. Signal intensity had decreased in the range where T 1 and T 2 values were extremely short. (author)

  11. Spin dependence in high $p^{2}_{T}$ elastic pp and np scattering

    CERN Document Server

    Crabb, D G; Hansen, P.H.; Hauser, J.; Krisch, A.D.; Sandler, B.; Shima, T.; Terwilliger, K.M.; Crosbie, E.A.; Ratner, L.G.; Schultz, P.F.; Thomas, G.H.; O'Fallon, J.R.; Lin, A.D.; Salthouse, A.J.; Linn, S.L.; Perlmutter, A.; Karmakar, N.L.; Kyberd, P.

    1979-01-01

    Using the polarized proton capability of the Argonne ZGS the authors recently made 90 degrees /sub cm/ measurements of elastic pp scattering from 6 to 11.75 GeV/c, determining the parallel and anti- parallel pure initial spin state cross sections and the associated spin-spin parameter A/sub nn/ with the spins normal to the scattering plane. They find that the parallel to anti-parallel cross section ratio rises dramatically from 1.2+or-.06 at p/sub t//sup 2/=3.3 (GeV /c)/sup 2/ to 3.2+or-.4 at 4.8 (GeV/c)/sup 2/, similar to the p/sub T //sup 2/ dependence previously observed at the fixed laboratory momentum of 11.75 GeV/c. They have also extended the measurements at 6 GeV/c and find that A/sub nn/ has a small but sharp rise at 90 degrees /sub cm/. In addition a month of 12 GeV/c polarized deuteron acceleration in the ZGS enabled them to measure two A/sub nn/ at two points at 6 GeV/c for np elastic scattering: A/sub nn/=-.17+or-.04 at p/sub T//sup 2/=.8, A/sub nn/=-.19+or-.05 at P/sub T//sup 2/=1.0. These value...

  12. Improved abdominal MRI in non-breath-holding children using a radial k-space sampling technique

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Hyuk; Choi, Young Hun; Cheon, Jung Eun; Lee, So Mi; Cho, Hyun Hae; Kim, Woo Sun; Kim, In One [Seoul National University Children' s Hospital, Department of Radiology, Seoul (Korea, Republic of); Shin, Su Mi [SMG-SNU Boramae Medical Center, Department of Radiology, Seoul (Korea, Republic of)

    2015-06-15

    Radial k-space sampling techniques have been shown to reduce motion artifacts in adult abdominal MRI. To compare a T2-weighted radial k-space sampling MRI pulse sequence (BLADE) with standard respiratory-triggered T2-weighted turbo spin echo (TSE) in pediatric abdominal imaging. Axial BLADE and respiratory-triggered turbo spin echo sequences were performed without fat suppression in 32 abdominal MR examinations in children. We retrospectively assessed overall image quality, the presence of respiratory, peristaltic and radial artifact, and lesion conspicuity. We evaluated signal uniformity of each sequence. BLADE showed improved overall image quality (3.35 ± 0.85 vs. 2.59 ± 0.59, P < 0.001), reduced respiratory motion artifact (0.51 ± 0.56 vs. 1.89 ± 0.68, P < 0.001), and improved lesion conspicuity (3.54 ± 0.88 vs. 2.92 ± 0.77, P = 0.006) compared to respiratory triggering turbo spin-echo (TSE) sequences. The bowel motion artifact scores were similar for both sequences (1.65 ± 0.77 vs. 1.79 ± 0.74, P = 0.691). BLADE introduced a radial artifact that was not observed on the respiratory triggering-TSE images (1.10 ± 0.85 vs. 0, P < 0.001). BLADE was associated with diminished signal variation compared with respiratory triggering-TSE in the liver, spleen and air (P < 0.001). The radial k-space sampling technique improved the quality and reduced respiratory motion artifacts in young children compared with conventional respiratory-triggered turbo spin-echo sequences. (orig.)

  13. Are T2-weighted images necessary in renal mass characterization?

    International Nuclear Information System (INIS)

    Dann, Phoebe; Thakur, Ravi; Chin, Deanne; Krinsky, Glenn; Israel, Gary M.

    2006-01-01

    Objective: To determine what role T2-weighted images play in characterizing renal masses. Methods: Forty-four pathologically proven renal masses (34 renal cell carcinomas, 8 oncocytomas, 1 metanephric adenoma, 1 angiomyolipoma without macroscopic fat) and 38 simple renal cysts were evaluated with T1- and T2-weighted images at 1.5 T. Two independent and blinded readers initially characterized all masses using only the T1-weighed images (in- and opposed-phase chemical shift, unenhanced frequency-selective fat-suppressed, gadolinium-enhanced frequency-selective fat-suppressed and subtraction images) and placed each mass into one of three categories: nonsurgical, in need of follow-up, or surgical. The masses were then re-evaluated with the addition of the T2-weighted images. It was determined if the T2-weighted images changed the initial classification. Results: Forty-three of the 44 (98%) pathologically proven renal masses were characterized as a surgical mass using only the T1-weighted images. The remaining renal mass (a renal cell carcinoma) was characterized as a mass in which follow-up exams would be suggested. Thirty-eight of 38 (100%) simple renal cysts were correctly characterized using only the T1-weighted images. The T2-weighted images did not change the initial interpretation of the T1-weighted images in any of the cases. Conclusion: The results of this study suggest that T2-weighted images are not necessary in the evaluation of all renal masses and are specifically not necessary in the differentiation of solid and cystic renal neoplasms from simple renal cysts

  14. Agreement between T2 and haste sequences in the evaluation of thoracolumbar intervertebral disc disease in dogs.

    Science.gov (United States)

    Mankin, Joseph M; Hecht, Silke; Thomas, William B

    2012-01-01

    The purpose of this study was to compare half-Fourier-acquisition single-shot turbo spin-echo (HASTE) and T2-weighted (T2-W) sequences in dogs with thoracolumbar disc extrusion. MRI studies in 60 dogs (767 individual intervertebral disc spaces) were evaluated. Agreement between T2-W and HASTE sequences was assessed for two criteria: presence of an extradural lesion and treatment recommendation. There was moderate agreement between T2-W and HASTE sequences as to presence of an extradural lesion (kappa = 0.575). HASTE was in agreement in 96.1% of the sites where no extradural lesion was identified on T2-W images, but only in 58.1% of the sites where extradural lesions were identified on T2-W images. There was also moderate agreement between T2-W and HASTE sequences as to treatment recommendations (kappa = 0.476). HASTE was in agreement in 98.4% of the sites where a lesion was considered nonsurgical on T2 but only 82.1% of sites a lesion was considered surgical on T2. In 1.0% of sites considered not surgical and in 9.8% of sites considered equivocal based on T2-W images, a surgical lesion was identified on HASTE. Acquisition of a HASTE sequence in addition to conventional sequences may be beneficial in determining the severity of spinal cord compression in some cases when evaluating the canine spine.

  15. Calculation of T2 relaxation time from ultrafast single shot sequences for differentiation of liver tumors. Comparison of echo-planar, HASTE, and spin-echo sequences

    International Nuclear Information System (INIS)

    Abe, Yasuko; Yamashita, Yasuyuki; Tang, Yi; Namimoto, Tomohiro; Takahashi, Mutsumasa

    2000-01-01

    The purpose of this study was to evaluate the accuracy of T2 calculation from single shot imaging sequences such as echo-planar imaging (EPI) and half-Fourier single shot turbo spin-echo (HASTE) imaging. For the phantom study, we prepared vials containing different concentrations of agarose, copper sulfate, and nickel chloride. The temperature of the phantom was kept at 22 deg C. MR images were obtained with a 1.5-Tesla superconductive magnet. Spin-echo (SE)-type EPI and HASTE sequences with different TEs were obtained for T2 calculation, and the T2 values were compared with those obtained from the Carr-Purcell-Meiborm-Gill (CPMG) sequence. The clinical study group consisted of 30 consecutive patients referred for MR imaging to characterize focal liver lesions. A total of 40 focal liver lesions were evaluated, including 25 primary or metastatic solid masses and 15 non-solid lesions. Single shot SE-type EPI and HASTE were both performed with TEs of 64 and 90 msec. In the phantom study, the T2 values obtained from both single shot sequences showed significant correlations with those from the CPMG sequence (T2 on EPI vs. T2 on CPMG: r=0.98, p<0.01; T2 on HASTE vs. T2 on CPMG: r=0.99, p<0.01). In the clinical study, mean T2 values for liver calculated from EPI (42 msec) were significantly shorter than those calculated from the HASTE sequence (58 msec) (p<0.001). Mean T2 values for solid tumors were 95 msec with HASTE and 72 msec with EPI, and mean T2 values for non-solid lesions were 128 msec with HASTE and 159 msec with EPI. Although mean T2 values between solid and non-solid lesions were significantly different for both EPI and HASTE sequences (p=0.01 for HASTE, p<0.001 for EPI), the overlap of solid and non-solid lesions was less frequent in EPI than in HASTE. With single shot sequences, it is possible to obtain the T2 values that show excellent correlation with the CPMG sequence. Although both HASTE and EPI are useful to calculate T2 values, EPI appears to be more

  16. Abdominal applications of 3.0-T MR imaging: comparative review versus a 1.5-T system.

    Science.gov (United States)

    Choi, Jin-Young; Kim, Myeong-Jin; Chung, Yong Eun; Kim, Ji Youn; Jones, Alun C; de Becker, Jan; van Cauteren, Marc

    2008-01-01

    With the development of dedicated receiver coils and increased gradient performance, 3.0-T magnetic resonance (MR) systems are gaining wider acceptance in clinical practice. The expected twofold increase in signal-to-noise ratio (SNR) compared with that of 1.5-T MR systems may help improve spatial resolution or increase temporal resolution when used with parallel acquisition techniques. Several issues must be considered when applying 3.0-T MR in the abdomen, including the alteration of the radiofrequency field and relaxation time, increase in energy deposition and susceptibility effects, and problems associated with motion artifacts. For the evaluation of liver lesions, higher SNR and greater resolution achieved with the 3.0-T system could translate into better detection of malignant lesions on T2-weighted images obtained with adjusted imaging parameters. For the evaluation of pancreatic and biliary diseases, high-resolution T2-weighted imaging using single-shot turbo spin-echo sequences is useful; improvement in SNR was noticeable on two-dimensional MR cholangiopancreatographic images. For the preoperative imaging of rectal cancer, a single-shot sequence is useful for dramatically decreasing imaging time while maintaining image quality. Substantial modification of examination protocols, with optimized imaging parameters and sequence designs along with ongoing development of hardware, could contribute to an increased role of the 3.0-T system for abdominal MR examinations.

  17. Comparison of T1-weighted 2D TSE, 3D SPGR, and two-point 3D Dixon MRI for automated segmentation of visceral adipose tissue at 3 Tesla.

    Science.gov (United States)

    Fallah, Faezeh; Machann, Jürgen; Martirosian, Petros; Bamberg, Fabian; Schick, Fritz; Yang, Bin

    2017-04-01

    To evaluate and compare conventional T1-weighted 2D turbo spin echo (TSE), T1-weighted 3D volumetric interpolated breath-hold examination (VIBE), and two-point 3D Dixon-VIBE sequences for automatic segmentation of visceral adipose tissue (VAT) volume at 3 Tesla by measuring and compensating for errors arising from intensity nonuniformity (INU) and partial volume effects (PVE). The body trunks of 28 volunteers with body mass index values ranging from 18 to 41.2 kg/m 2 (30.02 ± 6.63 kg/m 2 ) were scanned at 3 Tesla using three imaging techniques. Automatic methods were applied to reduce INU and PVE and to segment VAT. The automatically segmented VAT volumes obtained from all acquisitions were then statistically and objectively evaluated against the manually segmented (reference) VAT volumes. Comparing the reference volumes with the VAT volumes automatically segmented over the uncorrected images showed that INU led to an average relative volume difference of -59.22 ± 11.59, 2.21 ± 47.04, and -43.05 ± 5.01 % for the TSE, VIBE, and Dixon images, respectively, while PVE led to average differences of -34.85 ± 19.85, -15.13 ± 11.04, and -33.79 ± 20.38 %. After signal correction, differences of -2.72 ± 6.60, 34.02 ± 36.99, and -2.23 ± 7.58 % were obtained between the reference and the automatically segmented volumes. A paired-sample two-tailed t test revealed no significant difference between the reference and automatically segmented VAT volumes of the corrected TSE (p = 0.614) and Dixon (p = 0.969) images, but showed a significant VAT overestimation using the corrected VIBE images. Under similar imaging conditions and spatial resolution, automatically segmented VAT volumes obtained from the corrected TSE and Dixon images agreed with each other and with the reference volumes. These results demonstrate the efficacy of the signal correction methods and the similar accuracy of TSE and Dixon imaging for automatic volumetry of VAT at 3 Tesla.

  18. Separate Turbo Code and Single Turbo Code Adaptive OFDM Transmissions

    Directory of Open Access Journals (Sweden)

    Burr Alister

    2009-01-01

    Full Text Available Abstract This paper discusses the application of adaptive modulation and adaptive rate turbo coding to orthogonal frequency-division multiplexing (OFDM, to increase throughput on the time and frequency selective channel. The adaptive turbo code scheme is based on a subband adaptive method, and compares two adaptive systems: a conventional approach where a separate turbo code is used for each subband, and a single turbo code adaptive system which uses a single turbo code over all subbands. Five modulation schemes (BPSK, QPSK, 8AMPM, 16QAM, and 64QAM are employed and turbo code rates considered are and . The performances of both systems with high ( and low ( BER targets are compared. Simulation results for throughput and BER show that the single turbo code adaptive system provides a significant improvement.

  19. Usefulness of IDEAL T2-weighted FSE and SPGR imaging in reducing metallic artifacts in the postoperative ankles with metallic hardware

    International Nuclear Information System (INIS)

    Lee, Jung Bin; Cha, Jang Gyu; Lee, Min Hee; Lee, Eun Hye; Lee, Young Koo; Jeon, Chan Hong

    2013-01-01

    The aim of this work is to prospectively compare the effectiveness of iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL), T2-weighted fast spin-echo (FSE), and spoiled gradient-echo (SPGR) MR imaging to frequency selective fat suppression (FSFS) protocols for minimizing metallic artifacts in postoperative ankles with metallic hardware. The T2-weighted and SPGR imaging with IDEAL and FSFS were performed on 21 ankles of 21 patients with metallic hardware. Two musculoskeletal radiologists independently analyzed techniques for visualization of ankle ligaments and articular cartilage, uniformity of fat saturation, and relative size of the metallic artifacts. A paired t test was used for statistical comparisons of MR images between IDEAL and FSFS groups. IDEAL T2-weighted FSE and SPGR images enabled significantly improved visualization of articular cartilage (p < 0.05), the size of metallic artifact (p < 0.05), and the uniformity of fat saturation (p < 0.05). However, no significant improvement was found in the visibility of ligaments. IDEAL T2-weighted FSE and SPGR imaging effectively reduces the degree of tissue-obscuring artifacts produced by fixation hardware in ankle joints and improves image quality compared to FSFS T2-weighted FSE and SPGR imaging. However, visibility of ligaments was not improved using IDEAL imaging. (orig.)

  20. Magnetic resonance imaging of the sacroiliac joints in patients with suspected spondyloarthritis. Comparison of turbo spin-echo and gradient-echo sequences for the detection of structural alterations

    International Nuclear Information System (INIS)

    Dornia, C.; Hoffstetter, P.; Asklepios Klinikum, Bad Abbach; Fleck, M.; Asklepios Klinikum, Bad Abbach; Hartung, W.; Niessen, C.; Stroszczynski, C.

    2015-01-01

    Magnetic resonance imaging (MRI) is the method of choice for the evaluation of spondyloarthritis (SpA). According to the guidelines of the Assessment of Spondyloarthritis International Society (ASAS) and Outcome Measures in Rheumatology (OMERACT), MRI findings in SpA of the spine and the sacroiliac joints (SIJ) are classified as inflammatory and structural alterations. Modern gradient-echo sequences (GRE) are recommended for optimized detection of structural alterations of the SIJ. We assess the benefit of GRE in the detection of structural alterations of the SIJ in comparison to conventional turbo spin-echo sequences (TSE). Retrospective study of 114 patients who received MRI of the SIJ for the evaluation of SpA. Structural alterations of the SIJ were assessed by two blinded readers separately for T1 TSE and T2 * GRE. The findings were classified according to a previously published chronicity score separately for both sides and sequences. Interobserver reliability was calculated with Cohen's Kappa, and the significance of findings was assessed with the Wilcoxon test. P-values * GRE showed a high interobserver reliability in the detection of structural alterations in patients with SpA. However, T2 * GRE detected significantly more structural alterations than T1 TSE and should be an integral part of a modern MRI protocol for the diagnostic workup of patients with suspected SpA.

  1. 3.0 T MR imaging of the ankle: Axial traction for morphological cartilage evaluation, quantitative T2 mapping and cartilage diffusion imaging—A preliminary study

    International Nuclear Information System (INIS)

    Jungmann, Pia M.; Baum, Thomas; Schaeffeler, Christoph; Sauerschnig, Martin; Brucker, Peter U.; Mann, Alexander; Ganter, Carl; Bieri, Oliver

    2015-01-01

    Highlights: • Axial traction is applicable during high resolution MR imaging of the ankle. • Axial traction during MR imaging oft the ankle improves cartilage surface delineation of the individual tibial and talar cartilage layer for better morphological evaluation without the need of intraarticular contrast agent application. • Coronal T1-weighted MR images with a driven equilibrium pulse performed best. • Axial traction during MR imaging of the ankle facilitates compartment discrimination for segmentation purposes resulting in better reproducibility. - Abstract: Purpose: To determine the impact of axial traction during high resolution 3.0 T MR imaging of the ankle on morphological assessment of articular cartilage and quantitative cartilage imaging parameters. Materials and Methods: MR images of n = 25 asymptomatic ankles were acquired with and without axial traction (6 kg). Coronal and sagittal T1-weighted (w) turbo spin echo (TSE) sequences with a driven equilibrium pulse and sagittal fat-saturated intermediate-w (IMfs) TSE sequences were acquired for morphological evaluation on a four-point scale (1 = best, 4 = worst). For quantitative assessment of cartilage degradation segmentation was performed on 2D multislice-multiecho (MSME) SE T2, steady-state free-precession (SSFP; n = 8) T2 and SSFP diffusion-weighted imaging (DWI; n = 8) images. Wilcoxon-tests and paired t-tests were used for statistical analysis. Results: With axial traction, joint space width increased significantly and delineation of cartilage surfaces was rated superior (P < 0.05). Cartilage surfaces were best visualized on coronal T1-w images (P < 0.05). Differences for cartilage matrix evaluation were smaller. Subchondral bone evaluation, motion artifacts and image quality were not significantly different between the acquisition methods (P > 0.05). T2 values were lower at the tibia than at the talus (P < 0.001). Reproducibility was better for images with axial traction. Conclusion

  2. 3.0 T MR imaging of the ankle: Axial traction for morphological cartilage evaluation, quantitative T2 mapping and cartilage diffusion imaging—A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Jungmann, Pia M., E-mail: pia.jungmann@tum.de [Department of Radiology, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Strasse 22, 81675 Munich (Germany); Baum, Thomas, E-mail: thomas.baum@tum.de [Department of Radiology, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Strasse 22, 81675 Munich (Germany); Schaeffeler, Christoph, E-mail: schaeffeler@me.com [Department of Radiology, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Strasse 22, 81675 Munich (Germany); Musculoskeletal Imaging, Kantonsspital Graubuenden, Loestrasse 170, CH-7000 Chur (Switzerland); Sauerschnig, Martin, E-mail: martin.sauerschnig@mri.tum.de [Department of Trauma Surgery, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Strasse 22, 81675 Munich (Germany); Department of Orthopaedic Sports Medicine, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Strasse 22, 81675 Munich (Germany); Brucker, Peter U., E-mail: peter.brucker@lrz.tu-muenchen.de [Department of Orthopaedic Sports Medicine, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Strasse 22, 81675 Munich (Germany); Mann, Alexander, E-mail: abmann@onlinemed.de [Department of Radiology, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Strasse 22, 81675 Munich (Germany); Department of Orthopaedic Sports Medicine, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Strasse 22, 81675 Munich (Germany); Ganter, Carl, E-mail: cganter@tum.de [Department of Radiology, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Strasse 22, 81675 Munich (Germany); Bieri, Oliver, E-mail: oliver.bieri@unibas.ch [Division of Radiological Physics, Department of Radiology, University of Basel Hospital, Petersgraben 4, 4031 Basel (Switzerland); and others

    2015-08-15

    Highlights: • Axial traction is applicable during high resolution MR imaging of the ankle. • Axial traction during MR imaging oft the ankle improves cartilage surface delineation of the individual tibial and talar cartilage layer for better morphological evaluation without the need of intraarticular contrast agent application. • Coronal T1-weighted MR images with a driven equilibrium pulse performed best. • Axial traction during MR imaging of the ankle facilitates compartment discrimination for segmentation purposes resulting in better reproducibility. - Abstract: Purpose: To determine the impact of axial traction during high resolution 3.0 T MR imaging of the ankle on morphological assessment of articular cartilage and quantitative cartilage imaging parameters. Materials and Methods: MR images of n = 25 asymptomatic ankles were acquired with and without axial traction (6 kg). Coronal and sagittal T1-weighted (w) turbo spin echo (TSE) sequences with a driven equilibrium pulse and sagittal fat-saturated intermediate-w (IMfs) TSE sequences were acquired for morphological evaluation on a four-point scale (1 = best, 4 = worst). For quantitative assessment of cartilage degradation segmentation was performed on 2D multislice-multiecho (MSME) SE T2, steady-state free-precession (SSFP; n = 8) T2 and SSFP diffusion-weighted imaging (DWI; n = 8) images. Wilcoxon-tests and paired t-tests were used for statistical analysis. Results: With axial traction, joint space width increased significantly and delineation of cartilage surfaces was rated superior (P < 0.05). Cartilage surfaces were best visualized on coronal T1-w images (P < 0.05). Differences for cartilage matrix evaluation were smaller. Subchondral bone evaluation, motion artifacts and image quality were not significantly different between the acquisition methods (P > 0.05). T2 values were lower at the tibia than at the talus (P < 0.001). Reproducibility was better for images with axial traction. Conclusion

  3. Isotropic resolution diffusion tensor imaging of lumbosacral and sciatic nerves using a phase-corrected diffusion-prepared 3D turbo spin echo.

    Science.gov (United States)

    Cervantes, Barbara; Van, Anh T; Weidlich, Dominik; Kooijman, Hendrick; Hock, Andreas; Rummeny, Ernst J; Gersing, Alexandra; Kirschke, Jan S; Karampinos, Dimitrios C

    2018-08-01

    To perform in vivo isotropic-resolution diffusion tensor imaging (DTI) of lumbosacral and sciatic nerves with a phase-navigated diffusion-prepared (DP) 3D turbo spin echo (TSE) acquisition and modified reconstruction incorporating intershot phase-error correction and to investigate the improvement on image quality and diffusion quantification with the proposed phase correction. Phase-navigated DP 3D TSE included magnitude stabilizers to minimize motion and eddy-current effects on the signal magnitude. Phase navigation of motion-induced phase errors was introduced before readout in 3D TSE. DTI of lower back nerves was performed in vivo using 3D TSE and single-shot echo planar imaging (ss-EPI) in 13 subjects. Diffusion data were phase-corrected per k z plane with respect to T 2 -weighted data. The effects of motion-induced phase errors on DTI quantification was assessed for 3D TSE and compared with ss-EPI. Non-phase-corrected 3D TSE resulted in artifacts in diffusion-weighted images and overestimated DTI parameters in the sciatic nerve (mean diffusivity [MD] = 2.06 ± 0.45). Phase correction of 3D TSE DTI data resulted in reductions in all DTI parameters (MD = 1.73 ± 0.26) of statistical significance (P ≤ 0.001) and in closer agreement with ss-EPI DTI parameters (MD = 1.62 ± 0.21). DP 3D TSE with phase correction allows distortion-free isotropic diffusion imaging of lower back nerves with robustness to motion-induced artifacts and DTI quantification errors. Magn Reson Med 80:609-618, 2018. © 2018 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. © 2018 The Authors Magnetic Resonance

  4. A comparison of lesion detection and conspicuity on T2-weighted images (T2 FFE), FLAIR and diffusion-weighted images in patients with traumatic brain injury

    International Nuclear Information System (INIS)

    Kwon, Eun Yong; Lee, Myeong sub; Kim, Myung Soon; Hong, In Soo; Kim, Young Ju; Whang, Gum

    2001-01-01

    To compare the lesion detectability and conspicuity in traumatic brain injury on T-2 FFE, FLAIR and diffusion weighted imaging (DWI) sequences. Thirty-three patients who underwent MR brain imaging after traumatic brain injury were reviewed. T-2 FFE, FLAIR and diffusion-weighted MR sequences were obtained and were compared in terms of the detectability and conspicuity of intra- and extra-axial lesions which showed abnormal signal intensities. Among 33 patients, a total of 108 lesions were found, T-2 FFE sequences detected 88(81%) of these, FLAIR sequences 91%(84%), and diffusion-weighted sequences 57(52%). In the case of petechial hemorrhagic lesions, 16 were detected by T-2 FFE imaging but only one by FLAIR and one by DWI. Sixteen extra-axial lesions (73%) were detected by T-2 FFE, 21 (95%) by FLAIR, and 11(50%) by DWI. Lesion conspicuity on FLAIR images was judged superior to that on T-2 FFE and diffusion-weighted images in 42 lesions (75%). Eleven extra-axial Lesions (92%) were more conspicuous on FLAIR than on T-2 FFE and DWI. For detecting traumatic brain lesions and determining their conspicuity, FLAIR imaging was more useful than T-2 FFE and diffusion weighting , while T-2 FFE imaging was more sensitive for the detecion of petechial hemorrhage. Although diffusion-weighted imaging was generally inferior to both FLAIR and T-2 FFE in terms of lesion detection and conspicuity, for some lesions it was superior. The results suggest that images obtained at each pulse sequence can be used as complementary imaging sequences, and that in traumatic brain injury, the acquisition of FLAIR, T-2 FFE and diffusion-weighted images is useful

  5. Progress of High Efficiency Centrifugal Compressor Simulations Using TURBO

    Science.gov (United States)

    Kulkarni, Sameer; Beach, Timothy A.

    2017-01-01

    Three-dimensional, time-accurate, and phase-lagged computational fluid dynamics (CFD) simulations of the High Efficiency Centrifugal Compressor (HECC) stage were generated using the TURBO solver. Changes to the TURBO Parallel Version 4 source code were made in order to properly model the no-slip boundary condition along the spinning hub region for centrifugal impellers. A startup procedure was developed to generate a converged flow field in TURBO. This procedure initialized computations on a coarsened mesh generated by the Turbomachinery Gridding System (TGS) and relied on a method of systematically increasing wheel speed and backpressure. Baseline design-speed TURBO results generally overpredicted total pressure ratio, adiabatic efficiency, and the choking flow rate of the HECC stage as compared with the design-intent CFD results of Code Leo. Including diffuser fillet geometry in the TURBO computation resulted in a 0.6 percent reduction in the choking flow rate and led to a better match with design-intent CFD. Diffuser fillets reduced annulus cross-sectional area but also reduced corner separation, and thus blockage, in the diffuser passage. It was found that the TURBO computations are somewhat insensitive to inlet total pressure changing from the TURBO default inlet pressure of 14.7 pounds per square inch (101.35 kilopascals) down to 11.0 pounds per square inch (75.83 kilopascals), the inlet pressure of the component test. Off-design tip clearance was modeled in TURBO in two computations: one in which the blade tip geometry was trimmed by 12 mils (0.3048 millimeters), and another in which the hub flow path was moved to reflect a 12-mil axial shift in the impeller hub, creating a step at the hub. The one-dimensional results of these two computations indicate non-negligible differences between the two modeling approaches.

  6. Difference between T1 and T2 weighted MR images in avascular necrosis of the femoral head

    International Nuclear Information System (INIS)

    Kokubo, Takashi; Yoshikawa, Koki; Itai, Yuzo; Iio, Masahiro; Takatori, Yoshio; Kamogawa, Morihide; Ninomiya, Setsuo

    1990-01-01

    T 1 and T 2 weighted MR images were compared in 32 hips with avascular necrosis, and the difference between them was discussed. In 27 of 32 hips, abnormal low intensity area in the affected femoral head is smaller in T 2 weighted images than in T 1 weighted images. The area of low intensity on T 1 weighted image and high on T 2 weighted image might be granuloma in reactive tissue and surrounding hyperemia. The difference between T 1 and T 2 weighted images must be taken into consideration especially in determination of the border of affected bone. (author)

  7. High-resolution T2-weighted MR imaging of the inner ear using a long echo-train-length 3D fast spin-echo sequence

    International Nuclear Information System (INIS)

    Naganawa, S.; Yamakawa, K.; Fukatsu, H.; Ishigaki, T.; Nakashima, T.; Sugimoto, H.; Aoki, I.; Miyazaki, M.; Takai, H.

    1996-01-01

    The purpose of this study was to assess the value of a long echo-train-length 3D fast spin-echo (3D-FSE) sequence in visualizing the inner ear structures. Ten normal ears and 50 patient ears were imaged on a 1.5T MR unit using a head coil. Axial high-resolution T2-weighted images of the inner ear and the internal auditory canal (IAC) were obtained in 15 min. In normal ears the reliability of the visualization for the inner ear structures was evaluated on original images and the targeted maximum intensity projection (MIP) images of the labyrinth. In ten normal ears, 3D surface display (3D) images were also created and compared with MIP images. On the original images the cochlear aqueduct, the vessels in the vicinity of the IAC, and more than three branches of the cranial nerves were visualized in the IAC in all the ears. The visibility of the endolympathic duct was 80%. On the MIP images the visibility of the three semicircular canals, anterior and posterior ampulla, and of more than two turns of the cochlea was 100%. The MIP images and 3D images were almost comparable. The visibility of the endolymphatic duct was 80% in normal ears and 0% in the affected ears of the patients with Meniere's disease (p<0.001). In one patient ear a small intracanalicular tumor was depicted clearly. In conclusion, the long echo train length T2-weighted 3D-FSE sequence enables the detailed visualization of the tiny structures of the inner ear and the IAC within a clinically acceptable scan time. Furthermore, obtaining a high contrast between the soft/bony tissue and the cerebrospinal/endolymph/perilymph fluid would be of significant value in the diagnosis of the pathologic conditions around the labyrinth and the IAC. (orig.)

  8. Dynamic T2-mapping during magnetic resonance guided high intensity focused ultrasound ablation of bone marrow

    International Nuclear Information System (INIS)

    Waspe, Adam C.; Looi, Thomas; Mougenot, Charles; Amaral, Joao; Temple, Michael; Sivaloganathan, Siv; Drake, James M.

    2012-01-01

    Focal bone tumor treatments include amputation, limb-sparing surgical excision with bone reconstruction, and high-dose external-beam radiation therapy. Magnetic resonance guided high intensity focused ultrasound (MR-HIFU) is an effective non-invasive thermotherapy for palliative management of bone metastases pain. MR thermometry (MRT) measures the proton resonance frequency shift (PRFS) of water molecules and produces accurate ( 2 , since T 2 increases linearly in fat during heating. T 2 -mapping using dual echo times during a dynamic turbo spin-echo pulse sequence enabled rapid measurement of T 2 . Calibration of T 2 -based thermal maps involved heating the marrow in a bovine femur and simultaneously measuring T 2 and temperature with a thermocouple. A positive T 2 temperature dependence in bone marrow of 20 ms/°C was observed. Dynamic T 2 -mapping should enable accurate temperature monitoring during MR-HIFU treatment of bone marrow and shows promise for improving the safety and reducing the invasiveness of pediatric bone tumor treatments.

  9. Development and tests of large nuclear turbo-generator welded rotors

    International Nuclear Information System (INIS)

    Colombie, H.; Thiery, M.; Rotzinger, R.; Pelissou, C.; Tabacco, C.; Fernagut, V.

    2015-01-01

    Turbo-generators require large forgings for the rotor and it is a worldwide practice to manufacture turbo-generator rotor bodies as single piece forgings. Rotors for nuclear applications (4-pole rotors design, 1500/1800 rpm) require forgings of up to 2.0 m diameter and ultra large ingots with weight more than 500 tons. Nowadays only few forge masters can deliver such forgings in the world. Based on the large welding experience Alstom has gained over decades on steam and gas turbines and Alstom's multi piece shrunk turbo-generator rotors, it was suggested to manufacture 4-pole turbo-generator rotors by welding the shaft from aligned cylindrical forgings. Compared to turbine welded rotors, the shaft of a turbo-generator rotor presents differences linked to dimensions/weight, weld depth and electrical application. The manufacture of a 2 disc model allowed to prove through electrical and mechanical analysis the reliability of the concept as well as the reliability of the manufacturing processes through material tests, micro sections, electrical component tests, weld geometry, welding processes (TIG,SAW,...), weld inspection (Ultrasonic testing, radiographic inspection,...) weld heat treatments and machining. Then a full rotor able to replace a single forging rotor was manufactured in order to validate and prove to potential customers the validity of the welded rotor technology. During the first order from EDF of a welded 900 MW spare rotor, the procedure for the Non Destructive Test on a slotted rotor was developed upon EDF request in order to compare future Non Destructive Testing with the finger print of the new rotor. This complete rotor was delivered to EDF in January 2013. This rotor is in operation in a nuclear unit since November 2013. (authors)

  10. Is there an added value of T1-weighted contrast-enhanced fat-suppressed spin-echo MR sequences compared to STIR sequences in MRI of the foot and ankle?

    Energy Technology Data Exchange (ETDEWEB)

    Zubler, Veronika; Zanetti, Marco; Dietrich, Tobias J.; Pfirrmann, Christian W.; Mamisch-Saupe, Nadja [University of Zurich, Faculty of Medicine, Zurich (Switzerland); Orthopedic University Hospital Balgrist, Department of Radiology, Zurich (Switzerland); Espinosa, Norman [University of Zurich, Faculty of Medicine, Zurich (Switzerland); Orthopedic University Hospital Balgrist, Orthopedic Surgery, Zurich (Switzerland)

    2017-08-15

    To prospectively compare T1-weighted fat-suppressed spin-echo magnetic resonance (MR) sequences after gadolinium application (T1wGdFS) to STIR sequences in patients with acute and chronic foot pain. In 51 patients referred for MRI of the foot and ankle, additional transverse and sagittal T1wGdFS sequences were obtained. Two sets of MR images (standard protocol with STIR or T1wGdFS) were analysed. Diagnosis, diagnostic confidence, and localization of the abnormality were noted. Standard of reference was established by an expert panel of two experienced MSK radiologists and one experienced foot surgeon based on MR images, clinical charts and surgical reports. Patients reported prospectively localization of pain. Descriptive statistics, McNemar test and Kappa test were used. Diagnostic accuracy with STIR protocol was 80% for reader 1, 67% for reader 2, with contrast-protocol 84%, both readers. Significance was found for reader 2. Diagnostic confidence for reader 1 was 1.7 with STIR, 1.3 with contrast-protocol; reader 2: 2.1/1.7. Significance was found for reader 1. Pain location correlated with STIR sequences in 64% and 52%, with gadolinium sequences in 70% and 71%. T1-weighted contrast material-enhanced fat-suppressed spin-echo magnetic resonance sequences improve diagnostic accuracy, diagnostic confidence and correlation of MR abnormalities with pain location in MRI of the foot and ankle. However, the additional value is small. (orig.)

  11. Is there an added value of T1-weighted contrast-enhanced fat-suppressed spin-echo MR sequences compared to STIR sequences in MRI of the foot and ankle?

    International Nuclear Information System (INIS)

    Zubler, Veronika; Zanetti, Marco; Dietrich, Tobias J.; Pfirrmann, Christian W.; Mamisch-Saupe, Nadja; Espinosa, Norman

    2017-01-01

    To prospectively compare T1-weighted fat-suppressed spin-echo magnetic resonance (MR) sequences after gadolinium application (T1wGdFS) to STIR sequences in patients with acute and chronic foot pain. In 51 patients referred for MRI of the foot and ankle, additional transverse and sagittal T1wGdFS sequences were obtained. Two sets of MR images (standard protocol with STIR or T1wGdFS) were analysed. Diagnosis, diagnostic confidence, and localization of the abnormality were noted. Standard of reference was established by an expert panel of two experienced MSK radiologists and one experienced foot surgeon based on MR images, clinical charts and surgical reports. Patients reported prospectively localization of pain. Descriptive statistics, McNemar test and Kappa test were used. Diagnostic accuracy with STIR protocol was 80% for reader 1, 67% for reader 2, with contrast-protocol 84%, both readers. Significance was found for reader 2. Diagnostic confidence for reader 1 was 1.7 with STIR, 1.3 with contrast-protocol; reader 2: 2.1/1.7. Significance was found for reader 1. Pain location correlated with STIR sequences in 64% and 52%, with gadolinium sequences in 70% and 71%. T1-weighted contrast material-enhanced fat-suppressed spin-echo magnetic resonance sequences improve diagnostic accuracy, diagnostic confidence and correlation of MR abnormalities with pain location in MRI of the foot and ankle. However, the additional value is small. (orig.)

  12. T2-weighted liver MRI using the multiVane technique at 3T: Comparison with conventional T2-weighted MRI

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Kyung A [Dept. of Radiology, Myongji Hospital, Seonam University College of Medicine, Goyang (Korea, Republic of); Kim, Young Kon; Jeong, Woo Kyoung; Choi, Dong Il; Lee, Won Jae [Dept. of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Kim, Eun Ju [Philips Healthcare Korea, Philips, Seoul (Korea, Republic of); Jung, Sin Ho; Baek, Sun Young [Biostatistics and Clinical Epidemiology Center, Samsung Medical Center, Seoul (Korea, Republic of)

    2015-10-15

    To assess the value of applying MultiVane to liver T2-weighted imaging (T2WI) compared with conventional T2WIs with emphasis on detection of focal liver lesions. Seventy-eight patients (43 men and 35 women) with 86 hepatic lesions and 20 pancreatico-biliary diseases underwent MRI including T2WIs acquired using breath-hold (BH), respiratory-triggered (RT), and MultiVane technique at 3T. Two reviewers evaluated each T2WI with respect to artefacts, organ sharpness, and conspicuity of intrahepatic vessels, hilar duct, and main lesion using five-point scales, and made pairwise comparisons between T2WI sequences for these categories. Diagnostic accuracy (Az) and sensitivity for hepatic lesion detection were evaluated using alternative free-response receiver operating characteristic analysis. MultiVane T2WI was significantly better than BH-T2WI or RT-T2WI for organ sharpness and conspicuity of intrahepatic vessels and main lesion in both separate reviews and pairwise comparisons (p < 0.001). With regard to motion artefacts, MultiVane T2WI or BH-T2WI was better than RT-T2WI (p < 0.001). Conspicuity of hilar duct was better with BH-T2WI than with MultiVane T2WI (p = 0.030) or RT-T2WI (p < 0.001). For detection of 86 hepatic lesions, sensitivity (mean, 97.7%) of MultiVane T2WI was significantly higher than that of BH-T2WI (mean, 89.5%) (p = 0.008) or RT-T2WI (mean, 84.9%) (p = 0.001). Applying the MultiVane technique to T2WI of the liver is a promising approach to improving image quality that results in increased detection of focal liver lesions compared with conventional T2WI.

  13. Gadolinium-enhanced T{sub 1}-weighted MR urography versus T{sub 2}-weighted (HASTE) MR urography in children; Kontrastangehobene T{sub 1}-gewichtete MR-Urographie versus T{sub 2}-gewichtete (HASTE) MR-Urographie im Kindesalter

    Energy Technology Data Exchange (ETDEWEB)

    Staatz, G.; Nolte-Ernsting, C.C.A.; Haage, P.; Tacke, J.; Guenther, R.W. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik; Rohrmann, D. [Technische Hochschule Aachen (Germany). Urologische Klinik; Stollbrink, C. [Technische Hochschule Aachen (Germany). Kinderklinik

    2001-11-01

    Purpose: To evaluate gadolinium-enhanced T{sub 1}-weighted excretory MR urography (EMRU) versus T{sub 2}-weighted (HASTE) MR urography in children with upper urinary tract abnormalities. Patients and Methods: In a prospective study 63 children, aged from 3 weeks to 15 years, underwent MR urography in a 1.5-T scanner. Before and after an intravenous injection of 0.05 mg/kg body weight of furosemide, respiratory-triggered HASTE images were obtained for T{sub 2}-weighted MR urography. EMRU was performed subsequent to i.v. gadolinium injection with respiratory-gated, coronal 3D-gradient-echo sequences. Results: Compared to T{sub 2}-weighted (HASTE) MR urography, gadolinium-enhanced MR urography revealed a superior diagnostic accuracy in non-dilated collecting systems (horseshoe kidneys, ectopic kidneys, duplex systems, single ectopic ureters, ureteroceles). EMRU and T{sub 2}-weighted (HASTE) MRU turned out to be equivalent in the assessment of obstructed but normal functioning upper urinary tracts (UPJ obstructions, megaureters). Non-functioning dilated collecting systems and multicystic dysplastic kidneys were best visualized with use of T{sub 2}-weighted (HASTE) MR urography. Conclusion: Respiratory-gated gadolinium-enhanced T{sub 1}-weighted MRU allows accurate evaluation of most upper urinary tract abnormalities. T{sub 2}-weighted (HASTE) MRU complements GMRU in the evaluation of non-functioning renal units and cystic disease of the kidneys. (orig.) [German] Ziel: Vergleich der kontrastangehobenen T{sub 1}-gewichteten MR-Urographie mit der T{sub 2}-gewichteten (HASTE) MR-Urographie bei Kindern mit Anomalien des oberen Harntraktes. Methoden: In einer prospektiven Studie wurde bei 63 Kindern (3 Wo. - 15J.) eine MR-Urographie (MRU) in einem 1,5-Tesla-Magneten durchgefuehrt. Die T{sub 2}-gewichtete MRU erfolgte vor und nach intravenoeser Injektion von 0,05 mg/kg KG Furosemid mit atemgetriggerten HASTE-Sequenzen. Fuer die T{sub 1}-gewichtete MRU wurden nach

  14. In Vivo Radiofrequency Heating in Swine in a 3T (123.2 MHz) Birdcage Whole-Body Coil

    Science.gov (United States)

    Shrivastava, Devashish; Utecht, Lynn; Tian, Jinfeng; Hughes, John; Vaughan, J. Thomas

    2014-01-01

    Purpose To study in vivo radiofrequency (RF) heating produced due to power deposition from a 3T (Larmour frequency = 123.2 MHz), birdcage, whole-body coil. Methods The RF heating was simulated in a digital swine by solving the mechanistic generic bioheat transfer model (GBHTM) and the conventional, empirical Pennes bioheat transfer equation for the following two cases: (1) when the porcine head was in the isocenter, and (2) when the porcine trunk was in the isocenter. The simulation results were validated by making direct fluoroptic temperature measurements in the skin, brain, simulated hot regions, and rectum of ten swine (Case 1, N= 5, mean animal weight = 84.03 ± 6.85 kg, Whole-body average SAR = 2.65 ± 0.22 W/kg; Case 2, N= 5, mean animal weight = 81.59 ± 6.23 kg, Whole-body average SAR = 2.77 ± 0.26 W/kg) during one hour of exposure to a turbo spin echo sequence. Results The GBHTM simulated the RF heating more accurately compared to the Pennes equation. In vivo temperatures exceeded safe temperature thresholds with allowable SAR exposures. Hot regions may be produced deep inside the body, away from the skin. Conclusion SAR exposures to produce safe temperature thresholds may need re-investigation. PMID:24259413

  15. Cerebral and meningeal manifestations of AIDS: comparison of plain T2-weighted images and Gd-DTPA enhanced T1-weighted images in 105 patients

    International Nuclear Information System (INIS)

    Jochens, R.; Henkes, H.; Steinkamp, H.J.; Terstegge, K.; Hosten, N.; Ruf, B.; Schoerner, W.

    1994-01-01

    The purpose of the present study was to evaluate the potential of T1-weighted Gd-DTPA enhanced MR imaging in the diagnosis of cerebral manifestations of AIDS. 105 patients with AIDS were imaged with plain T2-weighted images as well as with Gd-DTPA enhanced T1-weighted pulse sequences. Our study revealed comparable sensitivities in the detection of morphological changes as shown on plain T2-weighted images and Gd-DTPA enhanced T1-weighted images in 55% of patients (normal and pathologic findings). Plain T2-weighted images were superior in 28.5% and provided significantly better results in 8.5% of patients. Gd-DTPA enhanced T1-weighted images were superior in only 5% cases and revealed significantly better results in 3%. As a result, T2-weighted plain images were superior in approximately 40% of patients concerning detection of morphologic changes. In almost 10% of patients with parechymal and meningeal lesions, Gd-DTPA enhanced T1-weighted images, however, were superior or even significantly better compared to T2-weighted plain images. The detection of morphologic changes in MR imaging can be further increased with Gd-DTPA. With regard to differential diagnosis and diesease activity, plain T2-weighted images and Gd-DTPA enhanced T1-weighted images revealed comparable results in 42% of patients (normal and pathologic findings). T2-weighted plain images were superior in 2% of cases whereas Gd-DTPA enhanced T1-weighted images were superior in as much as 56% of patient. MR imaging enhanced with Gd-DTPA yielded additional information on disease activity in 73% of patients with pathologic findings in the cerebral parechyma and the meninges. The surplus of information also refers to the etiology of cerebral pathology and differential diagnosis. Because of the frequency of cerebral manifestations in AIDS, early diagnosis for initiation of therapy and follow-up studies to monitor therapy are crucial. (orig./MG) [de

  16. Interleaver Design for Turbo Coding

    DEFF Research Database (Denmark)

    Andersen, Jakob Dahl; Zyablov, Viktor

    1997-01-01

    By a combination of construction and random search based on a careful analysis of the low weight words and the distance properties of the component codes, it is possible to find interleavers for turbo coding with a high minimum distance. We have designed a block interleaver with permutations...

  17. Assessment of T2- and T1-weighted MRI brain lesion load in patients with subcortical vascular encephalopathy

    International Nuclear Information System (INIS)

    Gass, A.; Oster, M.; Cohen, S.; Daffertshofer, M.; Schwartz, A.; Hennerici, M.G.

    1998-01-01

    Previous cross-sectional studies in patients with subcortical vascular encephalopathy (SVE) have shown little or no correlation between brain lesion load and clinical disability, which could be due to the low specificity of T2-weighted MRI. Recent studies have indicated that T1-weighted MRI may be more specific than T2-weighted MRI for severe tissue destruction. We studied 37 patients with a diagnosis of SVE and 11 normal controls with standardised T1- and T2-weighted MRI. All patients underwent detailed clinical assessment including a neuropsychological test battery and computerised gait analysis. Both the T2- and T1-weighted total MRI lesion loads different between patients and controls different, particularly T1. The ratio of T2-/T1-weighted lesion load was lower in controls than in patients. There was no overall correlation of T1- or T2-weighted lesion load with clinical disability, but group comparison of patients with severe and mild clinical deficits showed different lesion loads. We suggest that T1- and T2-weighted MRI lesion loads demonstrate relevant structural abnormality in patients with SVE. (orig.)

  18. Combined use of T2-weighted and diffusion-weighted 3-T MR imaging for differentiating uterine sarcomas from benign leiomyomas

    International Nuclear Information System (INIS)

    Namimoto, Tomohiro; Yamashita, Yasuyuki; Awai, Kazuo; Nakaura, Takeshi; Yanaga, Yumi; Hirai, Toshinori; Saito, Tetsuo; Katabuchi, Hidetaka

    2009-01-01

    The objective of our study was to compare diffusion-weighted imaging (DWI) alone and DWI combined with T2-weighted MRI for the differentiation of uterine sarcomas from benign leiomyomas. T2-weighted imaging and DWI were performed in 103 patients with 103 myometrial tumours, including 8 uterine sarcomas and 95 benign leiomyomas on 3-T MR imaging. The signal intensity (SI) of the tumour on T2-weighted images was quantified as the tumour-myometrium contrast ratio (TCR) by using the following formula: (SI tumour - SI myometrium )/SI myometrium . The TCR or apparent diffusion coefficient (ADC) value alone and then the ADC value combined with T2-weighted imaging were evaluated for differentiation between sarcomas and leiomyomas. The mean ADC value of sarcomas was 0.86 ± 0.11 x 10 -3 m 2 /s, which was significantly lower than that of leiomyomas 1.18 ± 0.24 x 10 -3 m 2 /s; however, there was a substantial overlap. The mean TCR of sarcomas was 0.66 ± 0.71, which was significantly higher than that of the leiomyomas, -0.37 ± 0.34; however, again, there was a considerable overlap. When ADC was less than 1.05 x 10 -3 mm 2 /s and TCR was greater than 0 this condition was considered to confirm a sarcoma; a combination of ADC and TCR achieved a significant improvement without any overlap between sarcomas and leiomyomas (sensitivity 100%, specificity 100%). Our preliminary results indicate that combined DWI and T2-weighted MR imaging is better than DWI alone in the differentiation of uterine sarcomas from benign leiomyomas. (orig.)

  19. Proton T2 relaxation effect of superparamagnetic iron oxide. Comparison between fast spin echo and conventional spin echo sequence

    International Nuclear Information System (INIS)

    Tanimoto, Akihiro; Satoh, Yoshinori; Higuchi, Nobuya; Izutsu, Mutsumu; Yuasa, Yuji; Hiramatsu, Kyoichi

    1995-01-01

    Superparamagnetic iron oxide (SPIO) particles have been known to show a great T 2 relaxation effect in the liver, which contributes to significant liver signal decrease and detection of hepatic neoplasms. Recently, fast spin echo (FSE) sequence with less scanning time than conventional spin echo (SE) sequence has been rapidly introduced in clinical MR imaging. To investigate whether SPIO would show decreased T 2 relaxation effect on FSE, we obtained T 2 relaxivity (R2) of SPIO in vitro and liver signal decrease caused by SPIO in vivo. SPIO showed 20% less R2 on Carr-Purcell-Meiboom-Gill (CPMG) sequence than on SE. Relative liver signal-to-noise ratio (SNR) decrease caused by SPIO was significantly smaller (p 2 relaxation effect on FSE than on SE. However, further studies will be required to assess the diagnostic capability of SPIO on FSE, in the detection of hepatic neoplasms. (author)

  20. Performance of PROPELLER relative to standard FSE T2-weighted imaging in pediatric brain MRI

    Energy Technology Data Exchange (ETDEWEB)

    Vertinsky, A.T. [Vancouver General Hospital, Department of Radiology, Vancouver (Canada); University of British Columbia, Department of Radiology, Vancouver (Canada); Rubesova, Erika; Bammer, Sabine; White, Allan; Barnes, Patrick D. [Stanford University Medical Center, Lucile Salter Packard Children' s Hospital, Palo Alto, CA (United States); Krasnokutsky, Michael V. [Madigan Army Medical Center, Department of Radiology, Tacoma, WA (United States); Uniformed Services University of Health Sciences, Department of Radiology, Bethesda, MD (United States); Rosenberg, Jarrett; Bammer, Roland [Lucas Center, Stanford University, Department of Radiology, Palo Alto, CA (United States)

    2009-10-15

    T2-weighted fast spin-echo imaging (T2-W FSE) is frequently degraded by motion in pediatric patients. MR imaging with periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) employs alternate sampling of k-space to achieve motion reduction. To compare T2-W PROPELLER FSE (T2-W PROP) with conventional T2-W FSE for: (1) image quality; (2) presence of artefacts; and (3) ability to detect lesions. Ninety-five pediatric patients undergoing brain MRI (1.5 T) were evaluated with T2-W FSE and T2-W PROP. Three independent radiologists rated T2-W FSE and T2-W PROP, assessing image quality, presence of artefacts, and diagnostic confidence. Chi-square analysis and Wilcoxon signed rank test were used to assess the radiologists' responses. Compared with T2-W FSE, T2-W PROP demonstrated better image quality and reduced motion artefacts, with the greatest benefit in children younger than 6 months. Although detection rates were comparable for the two sequences, blood products were more conspicuous on T2-W FSE. Diagnostic confidence was higher using T2-W PROP in children younger than 6 months. Average inter-rater agreement was 87%. T2-W PROP showed reduced motion artefacts and improved diagnostic confidence in children younger than 6 months. Thus, use of T2-W PROP rather than T2-W FSE should be considered in routine imaging of this age group, with caution required in identifying blood products. (orig.)

  1. Performance of PROPELLER relative to standard FSE T2-weighted imaging in pediatric brain MRI

    International Nuclear Information System (INIS)

    Vertinsky, A.T.; Rubesova, Erika; Bammer, Sabine; White, Allan; Barnes, Patrick D.; Krasnokutsky, Michael V.; Rosenberg, Jarrett; Bammer, Roland

    2009-01-01

    T2-weighted fast spin-echo imaging (T2-W FSE) is frequently degraded by motion in pediatric patients. MR imaging with periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) employs alternate sampling of k-space to achieve motion reduction. To compare T2-W PROPELLER FSE (T2-W PROP) with conventional T2-W FSE for: (1) image quality; (2) presence of artefacts; and (3) ability to detect lesions. Ninety-five pediatric patients undergoing brain MRI (1.5 T) were evaluated with T2-W FSE and T2-W PROP. Three independent radiologists rated T2-W FSE and T2-W PROP, assessing image quality, presence of artefacts, and diagnostic confidence. Chi-square analysis and Wilcoxon signed rank test were used to assess the radiologists' responses. Compared with T2-W FSE, T2-W PROP demonstrated better image quality and reduced motion artefacts, with the greatest benefit in children younger than 6 months. Although detection rates were comparable for the two sequences, blood products were more conspicuous on T2-W FSE. Diagnostic confidence was higher using T2-W PROP in children younger than 6 months. Average inter-rater agreement was 87%. T2-W PROP showed reduced motion artefacts and improved diagnostic confidence in children younger than 6 months. Thus, use of T2-W PROP rather than T2-W FSE should be considered in routine imaging of this age group, with caution required in identifying blood products. (orig.)

  2. Comparison of STIR turbo SE imaging and diffusion-weighted imaging of the lung: capability for detection and subtype classification of pulmonary adenocarcinomas

    Energy Technology Data Exchange (ETDEWEB)

    Koyama, Hisanobu; Ohno, Yoshiharu; Onishi, Yumiko; Matsumoto, Keiko; Nogami, Munenobu; Takenaka, Daisuke; Sugimura, Kazuro [Kobe University Graduate School of Medicine, Department of Radiology, Kobe, Hyogo (Japan); Aoyama, Nobukazu [Kobe University Hospital, Division of Radiology, Kobe (Japan); Nishio, Wataru [Kobe University Graduate School of Medicine, Division of Cardiovascular, Thoracic and Pediatric Surgery, Kobe (Japan); Ohbayashi, Chiho [Hyogo Cancer Center, Division of Pathology, Akashi (Japan)

    2010-04-15

    The aim of the study was to evaluate the diagnostic performance of diffusion-weighted imaging (DWI) for detection and subtype classification in pulmonary adenocarcinomas through comparison with short TI inversion recovery turbo spin-echo imaging sequence (STIR). Thirty-two patients (mean age, 65.2 years) with 33 adenocarcinomas (mean diameter, 27.6 mm) were enrolled in this study. The detection rates of both sequences were compared. The ADC values on DWI and the contrast ratio (CR) between cancer and muscle on STIR were measured and those were compared across subtype classifications. Finally, ROC-based positive tests were performed to differentiate subtype classifications, and differentiation capabilities were compared. The DWI detection rate [85% (28/33)] was significantly lower than that of STIR [100% (33/33), P < 0.05]. The ADC values showed no significant difference regarding subtype classification; however, the CRs of bronchio-alveolar carcinomas (BACs) were significantly lower than those of other types (P < 0.05). When threshold values for differentiating BACs from others were adapted, the sensitivity and accuracy of DWI were significantly lower than those of STIR (P < 0.05). For differentiating adenocarcinomas with mixed subtypes from those with no BA component, there were no significant differences between the two sequences. STIR is more sensitive for detection and subtype classification than DWI. (orig.)

  3. Performance of JPEG Image Transmission Using Proposed Asymmetric Turbo Code

    Directory of Open Access Journals (Sweden)

    Siddiqi Mohammad Umar

    2007-01-01

    Full Text Available This paper gives the results of a simulation study on the performance of JPEG image transmission over AWGN and Rayleigh fading channels using typical and proposed asymmetric turbo codes for error control coding. The baseline JPEG algorithm is used to compress a QCIF ( "Suzie" image. The recursive systematic convolutional (RSC encoder with generator polynomials , that is, (13/11 in decimal, and 3G interleaver are used for the typical WCDMA and CDMA2000 turbo codes. The proposed asymmetric turbo code uses generator polynomials , that is, (13/11; 13/9 in decimal, and a code-matched interleaver. The effect of interleaver in the proposed asymmetric turbo code is studied using weight distribution and simulation. The simulation results and performance bound for proposed asymmetric turbo code for the frame length , code rate with Log-MAP decoder over AWGN channel are compared with the typical system. From the simulation results, it is observed that the image transmission using proposed asymmetric turbo code performs better than that with the typical system.

  4. Evaluation of T1/T2 ratios in a pilot study as a potential biomarker of biopsy: proven benign and malignant breast lesions in correlation with histopathological disease stage.

    Science.gov (United States)

    Malikova, Marina A; Tkacz, Jaroslaw N; Slanetz, Priscilla J; Guo, Chao-Yu; Aakil, Adam; Jara, Hernan

    2017-08-01

    Early breast cancer detection is important for intervention and prognosis. Advances in treatment and outcome require diagnostic tools with highly positive predictive value. To study the potential role of quantitative MRI (qMRI) using T1/T2 ratios to differentiate benign from malignant breast lesions. A cross-sectional study of 69 women with 69 known or suspicious breast lesions were scanned with mixed-turbo spin echo pulse sequence. Patients were grouped according to histopathological assessment of disease stage: untreated malignant tumor, treated malignancy and benign disease. Elevated T1/T2 means were observed for biopsy-proven malignant lesions and for malignant lesions treated prior to qMRI with chemotherapy and/or radiation, as compared with benign lesions. The qMRI-obtained T1/T2 ratios correlated with histopathology. Analysis revealed correlation between elevated T1/T2 ratio and disease stage. This could provide valuable complementary information on tissue properties as an additional diagnostic tool.

  5. Anteroinferior tears of the glenoid labrum: fat-suppressed fast spin-echo T2 versus gradient-recalled echo MR images

    Energy Technology Data Exchange (ETDEWEB)

    Tuite, M J [Department of Radiology, University of Wisconsin Hospital and Clinics, 600 Highland Avenue, Madison, WI 53792 (United States); De Smet, A A [Department of Radiology, University of Wisconsin Hospital and Clinics, 600 Highland Avenue, Madison, WI 53792 (United States); Norris, M A [Department of Radiology, University of Wisconsin Hospital and Clinics, 600 Highland Avenue, Madison, WI 53792 (United States); Orwin, J F [Department of Orthopedic Surgery, University of Wisconsin Hospital and Clinics, 600 Highland Avenue, Madison, WI 53792 (United States)

    1997-05-01

    Objective. To compare fat-suppressed fast spin-echo (FSE) T2-weighted images with gradient-recalled echo (GRE) T2*-weighted images in the evaluation of anteroinferior labral tears. Design. MR images were retrospectively reviewed by two radiologists masked to the history and arthroscopic findings. They separately interpreted the anteroinferior labrum as torn or intact, first on one pulse sequence and then, 4 weeks later, on the other sequence. The MR interpretations were correlated with the arthroscopic findings. Patients. Nine patients with anteroinferior labral tears, and nine similarly-aged patients with normal, labra were studied. Results and conclusions. Observer 1 had a sensitivity of 0.56 on the GRE images and 0.67 on the FSE images (P>0.5), with a specificity of 1.0 for both sequences. Observer 2 had a sensitivity of 0.78 and a specificity of 0.89 for both sequences. In this small study there is no significant difference between GRE and fat-suppressed FSE images in their ability to diagnose anteroinferior labral tears. When evaluating the labrum with conventional MRI, axial fat-suppressed FSE T2-weighted images can be used in place of GRE images without a loss of accuracy. (orig.). With 3 figs., 1 tab.

  6. The research of atmospheric 2D optical PPM CDMA system with turbo coding

    Science.gov (United States)

    Zhou, Xiuli; Li, Zaoxia

    2007-11-01

    The atmospheric two-dimensional optical code-division multiple-access (CDMA) systems using pulse-position modulation (PPM) and Turbo-coded were presented. We analyzed the bit-error rate (BER) of the proposed system using pulse-position modulation (PPM) with considering the effects of the scintillation, avalanche photodiode noise, thermal noise, and multi-user interference. We showed that the atmospheric two dimensional (2D) optical PPM CDMA systems can realize high-speed communications when the logarithm variance of the scintillation is less than 0.1, and the turbo-coded atmospheric optical CDMA system has better bit error rate(BER) performance than the atmospheric optical PPM CDMA systems without turbo-coded. We also showed that the turbo-coded system has better performance than the multi-user detection system.

  7. Comparison of axial T1 spin-echo and T1 fat-saturation magnetic resonance imaging techniques in the diagnosis of chondromalacia patellae.

    Science.gov (United States)

    Vanarthos, W J; Pope, T L; Monu, J U

    1994-12-01

    To test the diagnostic value of T1 spin-echo and T1 fat-saturated magnetic resonance images (MRIs), we reviewed axial T1-weighted images with and without fat saturation in 20 patients with clinically suspected chondromalacia of the patella. All scans were obtained on 1.5-MR units. The scans were randomly ordered and reviewed independently at different times by two radiologists without knowledge of the arthroscopy results. The sensitivity of the individual techniques for detecting grade 3 or 4 chondromalacia patellae was 92% for fat-saturated axial T1-weighted images alone, and 67% for axial T1-weighted images without fat saturation. The sensitivity of the combined techniques was 100% for grades 3 and 4 and 90% for all grades (0 to 4). Chondromalacia patellae is diagnosed more accurately by using T1 fat saturation than by using T1 spin-echo images. With a combination of the two techniques, accuracy is 90% to 100%.

  8. High-resolution STIR for 3-T MRI of the posterior fossa: visualization of the lower cranial nerves and arteriovenous structures related to neurovascular compression.

    Science.gov (United States)

    Hiwatashi, Akio; Yoshiura, Takashi; Yamashita, Koji; Kamano, Hironori; Honda, Hiroshi

    2012-09-01

    Preoperative evaluation of small vessels without contrast material is sometimes difficult in patients with neurovascular compression disease. The purpose of this retrospective study was to evaluate whether 3D STIR MRI could simultaneously depict the lower cranial nerves--fifth through twelfth--and the blood vessels in the posterior fossa. The posterior fossae of 47 adults (26 women, 21 men) without gross pathologic changes were imaged with 3D STIR and turbo spin-echo heavily T2-weighted MRI sequences and with contrast-enhanced turbo field-echo MR angiography (MRA). Visualization of the cranial nerves on STIR images was graded on a 4-point scale and compared with visualization on T2-weighted images. Visualization of the arteries on STIR images was evaluated according to the segments in each artery and compared with that on MRA images. Visualization of the veins on STIR images was also compared with that on MRA images. Statistical analysis was performed with the Mann-Whitney U test. There were no significant differences between STIR and T2-weighted images with respect to visualization of the cranial nerves (p > 0.05). Identified on STIR and MRA images were 94 superior cerebellar arteries, 81 anteroinferior cerebellar arteries, and 79 posteroinferior cerebellar arteries. All veins evaluated were seen on STIR and MRA images. There were no significant differences between STIR and MRA images with respect to visualization of arteries and veins (p > 0.05). High-resolution STIR is a feasible method for simultaneous evaluation of the lower cranial nerves and the vessels in the posterior fossa without the use of contrast material.

  9. Magnetic resonance imaging (MRI) and relaxation time mapping of concrete

    Science.gov (United States)

    Beyea, Steven Donald

    2001-07-01

    The use of Magnetic Resonance Imaging (MRI) of water in concrete is presented. This thesis will approach the problem of MR imaging of concrete by attempting to design new methods, suited to concrete materials, rather than attempting to force the material to suit the method. A number of techniques were developed, which allow the spatial observation of water in concrete in up to three dimensions, and permits the determination of space resolved moisture content, as well as local NMR relaxation times. These methods are all based on the Single-Point Imaging (SPI) method. The development of these new methods will be described, and the techniques validated using phantom studies. The study of one-dimensional moisture transport in drying concrete was performed using SPI. This work examined the effect of initial mixture proportions and hydration time on the drying behaviour of concrete, over a period of three months. Studies of drying concrete were also performed using spatial mapping of the spin-lattice (T1) and effective spin-spin (T2*) relaxation times, thereby permitting the observation of changes in the water occupied pore surface-to-volume ratio (S/V) as a function of drying. Results of this work demonstrated changes in the S/V due to drying, hydration and drying induced microcracking. Three-dimensional MRI of concrete was performed using SPRITE (Single-Point Ramped Imaging with T1 Enhancement) and turboSPI (turbo Single Point Imaging). While SPRITE allows for weighting of MR images using T 1 and T2*, turboSPI allows T2 weighting of the resulting images. Using relaxation weighting it was shown to be possible to discriminate between water contained within a hydrated cement matrix, and water in highly porous aggregates, used to produce low-density concrete. Three dimensional experiments performed using SPRITE and turboSPI examined the role of self-dessication, drying, initial aggregate saturation and initial mixture conditions on the transport of moisture between porous

  10. Lumbosacral lipoma : gadolinium-enhanced fat saturation T1 weighted MR image is necessary?

    International Nuclear Information System (INIS)

    Yoon, Man Won; Kim, Hyun Chul; Chung, Tae Woong; Seo, Jeong Jin; Chung, Gwang Woo; Kim, Yun Hyeon; Kim, Jae Kyu; Park, Jin Gyoon; Kang, Heoung Keun

    1999-01-01

    To evaluate the usefulness of contrast-enhanced fat saturation T1-weighted imaging for the evaluation of spinal lipoma, compared with clinical symptoms and surgical findings. Ten patients with lipomyelomeningocele, confirmed by surgery, were included in this study. In all cases, conventional spin echo T1-and T2-weighted MR imaging, and contrast-enhanced fat saturation T1-weighted imaging was performed to evaluate clinical symptoms, the position of the conus medullaris, the presence of cord tethering, and associated anomalies, and to compare the relative usefulness of the techniques. All ten patients were suffering from lipomyelomeningocele without filum terminale fibrolipoma or intradural lipoma. All cases were associated with cord tethering. As associated anomalies, there were seven cases of syringomyelia without hydrocephalus or anorectal anomaly. To evaluate the position of the spinal conus and the presence of cord tethering, conventional T1-weighted imaging was more useful than the contrast-enhanced fat saturation equivalent. In patients with early-stage spinal lipoma, MRI is useful for evaluation of the causes and position of cord tethering and associated anomalies Our results suggest that contrast-enhanced fat saturation T1-weighted images do not provide additional information concerning spinal lipoma, and that for the diagnosis of this condition, conventional T1 and T2-weighted images are more useful than those obtained by contrast-enhanced fat saturation T1-weighted imaging

  11. Fault diagnostics for turbo-shaft engine sensors based on a simplified on-board model.

    Science.gov (United States)

    Lu, Feng; Huang, Jinquan; Xing, Yaodong

    2012-01-01

    Combining a simplified on-board turbo-shaft model with sensor fault diagnostic logic, a model-based sensor fault diagnosis method is proposed. The existing fault diagnosis method for turbo-shaft engine key sensors is mainly based on a double redundancies technique, and this can't be satisfied in some occasions as lack of judgment. The simplified on-board model provides the analytical third channel against which the dual channel measurements are compared, while the hardware redundancy will increase the structure complexity and weight. The simplified turbo-shaft model contains the gas generator model and the power turbine model with loads, this is built up via dynamic parameters method. Sensor fault detection, diagnosis (FDD) logic is designed, and two types of sensor failures, such as the step faults and the drift faults, are simulated. When the discrepancy among the triplex channels exceeds a tolerance level, the fault diagnosis logic determines the cause of the difference. Through this approach, the sensor fault diagnosis system achieves the objectives of anomaly detection, sensor fault diagnosis and redundancy recovery. Finally, experiments on this method are carried out on a turbo-shaft engine, and two types of faults under different channel combinations are presented. The experimental results show that the proposed method for sensor fault diagnostics is efficient.

  12. Fault Diagnostics for Turbo-Shaft Engine Sensors Based on a Simplified On-Board Model

    Directory of Open Access Journals (Sweden)

    Yaodong Xing

    2012-08-01

    Full Text Available Combining a simplified on-board turbo-shaft model with sensor fault diagnostic logic, a model-based sensor fault diagnosis method is proposed. The existing fault diagnosis method for turbo-shaft engine key sensors is mainly based on a double redundancies technique, and this can’t be satisfied in some occasions as lack of judgment. The simplified on-board model provides the analytical third channel against which the dual channel measurements are compared, while the hardware redundancy will increase the structure complexity and weight. The simplified turbo-shaft model contains the gas generator model and the power turbine model with loads, this is built up via dynamic parameters method. Sensor fault detection, diagnosis (FDD logic is designed, and two types of sensor failures, such as the step faults and the drift faults, are simulated. When the discrepancy among the triplex channels exceeds a tolerance level, the fault diagnosis logic determines the cause of the difference. Through this approach, the sensor fault diagnosis system achieves the objectives of anomaly detection, sensor fault diagnosis and redundancy recovery. Finally, experiments on this method are carried out on a turbo-shaft engine, and two types of faults under different channel combinations are presented. The experimental results show that the proposed method for sensor fault diagnostics is efficient.

  13. Difference between T sub 1 and T sub 2 weighted MR images in avascular necrosis of the femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Kokubo, Takashi; Yoshikawa, Koki; Itai, Yuzo; Iio, Masahiro; Takatori, Yoshio; Kamogawa, Morihide; Ninomiya, Setsuo [Tokyo Univ. (Japan). Faculty of Medicine

    1990-01-01

    T{sub 1} and T{sub 2} weighted MR images were compared in 32 hips with avascular necrosis, and the difference between them was discussed. In 27 of 32 hips, abnormal low intensity area in the affected femoral head is smaller in T{sub 2} weighted images than in T{sub 1} weighted images. The area of low intensity on T{sub 1} weighted image and high on T{sub 2} weighted image might be granuloma in reactive tissue and surrounding hyperemia. The difference between T{sub 1} and T{sub 2} weighted images must be taken into consideration especially in determination of the border of affected bone. (author).

  14. Preliminary Validation and Verification of TURBO{sub D}ESIGN for S-CO{sub 2} Axial Compressor

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Je Kyoung; Lee, Jeong Ik; Ahn, Yoon Han; Kim, Seong Gu [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Yoon, Ho Joon; Addad, Yacine [Khalifa University of Science, Technology and Research, Abu Dhabi (United Arab Emirates)

    2012-05-15

    To use the advantages of Supercritical CO{sub 2}(S-CO{sub 2}) Brayton cycle for nuclear power plant, KAIST-Khalifa University joint research team has been focusing on S-CO{sub 2} turbomachinery development. TURBO{sub D}ESIGN code is one of the products of our researches to design a turbomachinery. The major feature of TURBO{sub D}ESIGN is that the formulation is based on the real gas and none of the ideal gas assumption was applied to the code. Thus, TURBO{sub D}ESIGN has high flexibility regarding the type of gases. In this paper, preliminary code validation and verification of TURBO{sub D}ESIGN will be discussed for axial type compressor design

  15. MRI T2 Mapping of the Knee Articular Cartilage Using Different Acquisition Sequences and Calculation Methods at 1.5 Tesla.

    Science.gov (United States)

    Mars, Mokhtar; Bouaziz, Mouna; Tbini, Zeineb; Ladeb, Fethi; Gharbi, Souha

    2018-06-12

    This study aims to determine how Magnetic Resonance Imaging (MRI) acquisition techniques and calculation methods affect T2 values of knee cartilage at 1.5 Tesla and to identify sequences that can be used for high-resolution T2 mapping in short scanning times. This study was performed on phantom and twenty-nine patients who underwent MRI of the knee joint at 1.5 Tesla. The protocol includes T2 mapping sequences based on Single Echo Spin Echo (SESE), Multi-Echo Spin Echo (MESE), Fast Spin Echo (FSE) and Turbo Gradient Spin Echo (TGSE). The T2 relaxation times were quantified and evaluated using three calculation methods (MapIt, Syngo Offline and monoexponential fit). Signal to Noise Ratios (SNR) were measured in all sequences. All statistical analyses were performed using the t-test. The average T2 values in phantom were 41.7 ± 13.8 ms for SESE, 43.2 ± 14.4 ms for MESE, 42.4 ± 14.1 ms for FSE and 44 ± 14.5 ms for TGSE. In the patient study, the mean differences were 6.5 ± 8.2 ms, 7.8 ± 7.6 ms and 8.4 ± 14.2 ms for MESE, FSE and TGSE compared to SESE respectively; these statistical results were not significantly different (p > 0.05). The comparison between the three calculation methods showed no significant difference (p > 0.05). t-Test showed no significant difference between SNR values for all sequences. T2 values depend not only on the sequence type but also on the calculation method. None of the sequences revealed significant differences compared to the SESE reference sequence. TGSE with its short scanning time can be used for high-resolution T2 mapping. ©2018The Author(s). Published by S. Karger AG, Basel.

  16. Seminal vesicle invasion in prostate cancer: prediction with combined T2-weighted and diffusion-weighted MR imaging

    International Nuclear Information System (INIS)

    Ren, Jing; Huan, Yi; Ge, YaLi; Chang, YingJuan; Yin, Hong; Sun, LiJun; Wang, He

    2009-01-01

    The aim of this study was to evaluate the usefulness of diffusion-weighted imaging (DWI) in detecting seminal vesicle invasion (SVI). A total of 283 patients underwent conventional MRI and DWI before prostate cancer surgery. The apparent diffusion coefficient (ADC) values of all PCa foci, SVI and seminal vesicle were measured. T2 images alone and then T2 images combined with DWI were scored for the likelihood of SVI. The area under the receiver operating characteristic curve (AUC) was used to assess accuracy. Statistical significance was inferred at P<0.05. On pathological analysis, 39 patients had SVI. The ADC values of SVI were significantly lower than those of SV. The AUC for T2-weighted imaging plus DW imaging (0.897) was significantly larger (P<0.05) than that for T2-weighted imaging alone (0.779). T2 images combined with DWI shows significantly higher accuracy than T2-weighted imaging alone in the detection of SVI. (orig.)

  17. Detectability of hepatocellular carcinoma: comparison of Gd-DTPA-enhanced and SPIO-enhanced MR imaging

    International Nuclear Information System (INIS)

    Kwak, Hyo Sung; Lee, Jeong Min; Kim In Hwan; Kim, Chong Soo; Han, Hyeun Young; Yoon, Kwon ha; Shin, Kyung Sook

    2000-01-01

    To compare the detectability of hepatocellular carcinoma (HCC) using superparamagnetic iron oxide (SPIO)-enhanced T2-weighted turbo spin echo (TSE), SPIO-enhanced T2-weighted FISP, and dynamic Gd-DTPA-enhanced fast low-angle shot (FLASH) MR images. In order to assess their hepatic lesions, 25 patients (20 men and 5 women) with HCC were enrolled in an MR study in which both gadolinium and Spiro were used. Since the lesions were most conspicuous during the phase of dynamic arterial dominant phase of dynamic gadolinium-enhanced imaging, this was the phase used for analysis. Images were analyzed qualitatively and quantitatively, and to compare the diagnostic value of gadolinium-enhanced imaging with that of SPIO-enhanced imaging for the detection of HCCs, a receiver-operated characteristic curve was obtained. Qualitative analysis revealed a significantly higher percentage of signal loss and a higher liver-lesion contrast-to-noise ratio on SPIO-enhanced FISP imaging than on SPIO-enhanced T2-weighted TSE imaging (p less than 0.05). It also showed that the lesions were most clearly visible on SPIO-enhanced FISP imaging (and significantly so), followed by SPIO-enhanced T2-weighted TSE imaging, and dynamic gadolinium-enhanced imaging. Imaging artifacts were more prominent on SPIO-enhanced T2-weighted TSE than on SPIO-enhanced PISF imaging or dynamic gadolinium-enhanced imaging (p less than 0.05). According to ROC analysis, SPIO-enhanced T2-weighted turbo spin echo (TSE) or SPIO-enhanced FISP imaging achieved higher accuracy than did dynamic gadolinium-enhanced FLASH imaging (p less than 0.05). For the detection of hepatocellular carcinomas, SPIO-enhanced MR imaging is better than gadolinium-enhanced FLASH imaging

  18. In vivo radiofrequency heating in swine in a 3T (123.2-MHz) birdcage whole body coil.

    Science.gov (United States)

    Shrivastava, Devashish; Utecht, Lynn; Tian, Jinfeng; Hughes, John; Vaughan, J Thomas

    2014-10-01

    To study in vivo radiofrequency (RF) heating produced due to power deposition from a 3T (Larmour frequency = 123.2 MHz), birdcage, whole body coil. The RF heating was simulated in a digital swine by solving the mechanistic generic bioheat transfer model (GBHTM) and the conventional, empirical Pennes bioheat transfer equation for two cases: 1) when the swine head was in the isocenter and 2) when the swine trunk was in the isocenter. The simulation results were validated by making direct fluoroptic temperature measurements in the skin, brain, simulated hot regions, and rectum of 10 swine (case 1: n = 5, mean animal weight = 84.03 ± 6.85 kg, whole body average SAR = 2.65 ± 0.22 W/kg; case 2: n = 5, mean animal weight = 81.59 ± 6.23 kg, whole body average SAR = 2.77 ± 0.26 W/kg) during 1 h of exposure to a turbo spin echo sequence. The GBHTM simulated the RF heating more accurately compared with the Pennes equation. In vivo temperatures exceeded safe temperature thresholds with allowable SAR exposures. Hot regions may be produced deep inside the body, away from the skin. SAR exposures that produce safe temperature thresholds need reinvestigation. Copyright © 2013 Wiley Periodicals, Inc.

  19. Analysis of the acoustic sound in MRI

    Energy Technology Data Exchange (ETDEWEB)

    Wada, Tetsuro; Hara, Akira; Kusakari, Jun; Yoshioka, Hiroshi; Niitsu, Mamoru; Itai, Yuji [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine; Ase, Yuji

    1999-04-01

    The noise level and power spectra of the acoustic sound exposed during the examination of Magnetic Resonance Imaging (MRI) using a MRI scanner (Philips Gyroscan 1.5 T) were measured at the position of the human auricle. The overall noise levels on T1-weighted images and T2-weighted images with Spin Echo were 105 dB and 98 dB, respectively. The overall noise level on T2-weighted images with Turbo Spin Echo was 110 dB. Fourier analysis revealed energy peaks ranging from 225 to 325 Hz and a steep high frequency cutoff for each pulse sequence. The MRI noise was not likely to cause permanent threshold shift. However, because of the inter-subject variation in susceptibility to acoustic trauma and to exclude the anxiety in patients, ear protectors were recommended for all patients during MRI testing. (author)

  20. MR contrast of ferritin and hemosiderin in the brain: comparison among gradient-echo, conventional spin-echo and fast spin-echo sequences

    Energy Technology Data Exchange (ETDEWEB)

    Haque, Tabassum Laz; Miki, Yukio; Kanagaki, Mitsunori; Takahashi, Takahiro; Yamamoto, Akira; Konishi, Junya; Nozaki, Kazuhiko; Hashimoto, Nobuo; Konishi, Junji

    2003-12-01

    Objective: To compare the magnetic resonance image contrasts due to ferritin and hemosiderin in the brain tissue among different pulse sequences. Materials and methods: Fourteen patients with cavernous hemangioma in the brain prospectively underwent MR imaging with T2*-weighted gradient-echo (GRE), T2-weighted conventional spin-echo (SE) and fast spin-echo (FSE) sequences. The relative contrast ratios (CRs) of the hypointense part of cavernous hemangioma, globus pallidus and putamen to the deep frontal white matter were measured on each pulse sequence and statistically analyzed using analysis of variance followed by paired t-test. Results: In the hypointense part of cavernous hemangioma, relative CRs were significantly lower on T2*-weighted GRE than on T2-weighted SE images (P=0.0001), and on T2-weighted SE than on T2-weighted FSE images (P=0.0001). In the globus pallidus, relative CRs were significantly lower on T2-weighted SE than on T2*-weighted GRE images (P=0.002), and on T2*-weighted GRE than on T2-weighted FSE images (P=0.0002). In the putamen, relative CRs were significantly lower on T2-weighted SE than on T2*-weighted GRE images (P=0.001), and there was no significant difference between CRs on T2-weighted FSE and T2*-weighted GRE images (P=0.90). Conclusion: Hemosiderin showed best image contrast on T2*-weighted GRE images but ferritin showed more prominent image contrast on T2-weighted SE than on T2*-weighted GRE images, which may help to determine an appropriate pulse sequence in neurological diseases associated with excessive ferritin accumulation.

  1. MR contrast of ferritin and hemosiderin in the brain: comparison among gradient-echo, conventional spin-echo and fast spin-echo sequences

    International Nuclear Information System (INIS)

    Haque, Tabassum Laz; Miki, Yukio; Kanagaki, Mitsunori; Takahashi, Takahiro; Yamamoto, Akira; Konishi, Junya; Nozaki, Kazuhiko; Hashimoto, Nobuo; Konishi, Junji

    2003-01-01

    Objective: To compare the magnetic resonance image contrasts due to ferritin and hemosiderin in the brain tissue among different pulse sequences. Materials and methods: Fourteen patients with cavernous hemangioma in the brain prospectively underwent MR imaging with T2*-weighted gradient-echo (GRE), T2-weighted conventional spin-echo (SE) and fast spin-echo (FSE) sequences. The relative contrast ratios (CRs) of the hypointense part of cavernous hemangioma, globus pallidus and putamen to the deep frontal white matter were measured on each pulse sequence and statistically analyzed using analysis of variance followed by paired t-test. Results: In the hypointense part of cavernous hemangioma, relative CRs were significantly lower on T2*-weighted GRE than on T2-weighted SE images (P=0.0001), and on T2-weighted SE than on T2-weighted FSE images (P=0.0001). In the globus pallidus, relative CRs were significantly lower on T2-weighted SE than on T2*-weighted GRE images (P=0.002), and on T2*-weighted GRE than on T2-weighted FSE images (P=0.0002). In the putamen, relative CRs were significantly lower on T2-weighted SE than on T2*-weighted GRE images (P=0.001), and there was no significant difference between CRs on T2-weighted FSE and T2*-weighted GRE images (P=0.90). Conclusion: Hemosiderin showed best image contrast on T2*-weighted GRE images but ferritin showed more prominent image contrast on T2-weighted SE than on T2*-weighted GRE images, which may help to determine an appropriate pulse sequence in neurological diseases associated with excessive ferritin accumulation

  2. Turbo coding, turbo equalisation and space-time coding for transmission over fading channels

    CERN Document Server

    Hanzo, L; Yeap, B

    2002-01-01

    Against the backdrop of the emerging 3G wireless personal communications standards and broadband access network standard proposals, this volume covers a range of coding and transmission aspects for transmission over fading wireless channels. It presents the most important classic channel coding issues and also the exciting advances of the last decade, such as turbo coding, turbo equalisation and space-time coding. It endeavours to be the first book with explicit emphasis on channel coding for transmission over wireless channels. Divided into 4 parts: Part 1 - explains the necessary background for novices. It aims to be both an easy reading text book and a deep research monograph. Part 2 - provides detailed coverage of turbo conventional and turbo block coding considering the known decoding algorithms and their performance over Gaussian as well as narrowband and wideband fading channels. Part 3 - comprehensively discusses both space-time block and space-time trellis coding for the first time in literature. Par...

  3. Hepatic hemangioma: Correlation of enhancement types with diffusion-weighted MR findings and apparent diffusion coefficients

    Energy Technology Data Exchange (ETDEWEB)

    Goshima, Satoshi [Department of Radiology, Gifu University Hospital, 1-1 Yanagido, Gifu 501-1194 (Japan)], E-mail: gossy@par.odn.ne.jp; Kanematsu, Masayuki [Department of Radiology, Gifu University Hospital, 1-1 Yanagido, Gifu 501-1194 (Japan); Department of Radiology Services, Gifu University Hospital, 1-1 Yanagido, Gifu 501-1194 (Japan); Kondo, Hiroshi [Department of Radiology, Gifu University Hospital, 1-1 Yanagido, Gifu 501-1194 (Japan); Yokoyama, Ryujiro; Kajita, Kimihiro [Department of Radiology Services, Gifu University Hospital, 1-1 Yanagido, Gifu 501-1194 (Japan); Tsuge, Yusuke [Department of Radiology, Gifu University Hospital, 1-1 Yanagido, Gifu 501-1194 (Japan); Shiratori, Yoshimune [Department of Medical Informatics, Gifu University School of Medicine, Gifu (Japan); Onozuka, Minoru [Department of Physiology and Neuroscience, Kanagawa Dental College, Yokosuka (Japan); Moriyama, Noriyuki [Research Center for Cancer Prevention and Screening, National Cancer Center Hospital, Tsukiji (Japan)

    2009-05-15

    Purpose: To correlate hepatic hemangioma enhancement types in gadolinium-enhanced magnetic resonance (MR) images with diffusion-weighted MR findings and apparent diffusion coefficients (ADCs). Materials and methods: Respiratory-triggered diffusion-weighted MR images (TR/TE, 2422/46 ms; parallel imaging factor, 2; b factor, 500 s/mm{sup 2}; number of averaging, 6) obtained in 35 patients with 44 hepatic hemangiomas diagnosed by gadolinium-enhanced MR and by follow-up imaging were retrospectively evaluated. Hemangiomas were classified into three enhancement types based on gadolinium-enhanced MR imaging findings: type I, early-enhancement type; type II, peripheral nodular enhancement type; type III, delayed enhancement type. Two blinded readers qualitatively assessed lesion sizes and signal intensities on T2-weighted turbo spin-echo and diffusion-weighted images. The ADCs of hemangiomas were also measured. Results: No significant difference was observed between the three enhancement types in terms of signal intensities on T2-weighted images. Signal intensities on diffusion-weighted images were lower in the order type I to III (P < .01), and mean ADCs were 2.18 x 10{sup -3}, 1.86 x 10{sup -3}, and 1.71 x 10{sup -3} mm{sup 2}/s for types I, II, and III, respectively (P < .01). No correlation was found between lesion sizes and ADCs. Conclusion: Hepatic hemangiomas were found to have enhancement type dependent signal intensities and ADCs on diffusion-weighted MR images. Further studies will have to substantiate that these diffusion patterns might reflect intratumoral blood flow or perfusion.

  4. Hypothalamic-pituitary vascularization in pituitary stalk transection syndrome: is the pituitary stalk really transected? The role of gadolinium-DTPA with spin-echo T1 imaging and turbo-FLASH technique

    International Nuclear Information System (INIS)

    Genovese, E.; Maghnie, M.; Beluffi, G.; Villa, A.; Sammarchi, L.; Severi, F.; Campani, R.

    1997-01-01

    We examined 14 patients, aged 10-25 years, with idiopathic hypopituitarism. All presented an ectopic posterior pituitary at the median eminence with a hypoplastic anterior pituitary on magnetic resonance imaging (MRI). Eight patients had isolated growth hormone deficit (IGHD) and six had multiple hormone deficits (MPHD). Unenhanced MRI showed the pituitary stalk, which was extremely thin, in only three patients, while T1-weighted images obtained after intravenous injection of gadopentetate dimeglumine (Gd-DTPA) showed a thin pituitary stalk in seven patients (six with IGHD and one with MPHD), demonstrating a preserved vascular component of the stalk. MRI with Gd-DTPA was more sensitive than unenhanced MRI in detecting the pituitary stalk in patients with hypopituitarism with an ectopic posterior pituitary: the stalk was demonstrated in 50 % of the cases (seven patients), versus 21.4 % (three patients) by unenhanced MRI. The dynamic study of the hypothalamo-hypophyseal axis performed with turbo-FLASH sequences after bolus injection of Gd-DTPA showed the residual anterior pituitary to have arterial enhancement times, which suggests that an arterial system compensates for the absent or diminished blood supply from the portal system, independent of stalk detection. (orig.). With 5 figs., 1 tab

  5. Hypothalamic-pituitary vascularization in pituitary stalk transection syndrome: is the pituitary stalk really transected? The role of gadolinium-DTPA with spin-echo T1 imaging and turbo-FLASH technique

    Energy Technology Data Exchange (ETDEWEB)

    Genovese, E. [Dept. of Radiology, IRCCS Policlinico S. Matteo, Pavia (Italy); Maghnie, M. [Dept. of Pediatrics, Univ. of Pavia (Italy); Beluffi, G. [Dept. of Radiodiagnosis, Section of Pediatric Radiology, IRCCS Policlinico S. Matteo, Pavia (Italy); Villa, A. [Dept. of Radiology, IRCCS Policlinico S. Matteo, Pavia (Italy); Sammarchi, L. [Dept. of Radiology, IRCCS Policlinico S. Matteo, Pavia (Italy); Severi, F. [Dept. of Pediatrics, Univ. of Pavia (Italy); Campani, R. [Dept. of Radiology, IRCCS Policlinico S. Matteo, Pavia (Italy)

    1997-01-01

    We examined 14 patients, aged 10-25 years, with idiopathic hypopituitarism. All presented an ectopic posterior pituitary at the median eminence with a hypoplastic anterior pituitary on magnetic resonance imaging (MRI). Eight patients had isolated growth hormone deficit (IGHD) and six had multiple hormone deficits (MPHD). Unenhanced MRI showed the pituitary stalk, which was extremely thin, in only three patients, while T1-weighted images obtained after intravenous injection of gadopentetate dimeglumine (Gd-DTPA) showed a thin pituitary stalk in seven patients (six with IGHD and one with MPHD), demonstrating a preserved vascular component of the stalk. MRI with Gd-DTPA was more sensitive than unenhanced MRI in detecting the pituitary stalk in patients with hypopituitarism with an ectopic posterior pituitary: the stalk was demonstrated in 50 % of the cases (seven patients), versus 21.4 % (three patients) by unenhanced MRI. The dynamic study of the hypothalamo-hypophyseal axis performed with turbo-FLASH sequences after bolus injection of Gd-DTPA showed the residual anterior pituitary to have arterial enhancement times, which suggests that an arterial system compensates for the absent or diminished blood supply from the portal system, independent of stalk detection. (orig.). With 5 figs., 1 tab.

  6. Pulsed arterial spin labeling using TurboFLASH with suppression of intravascular signal.

    Science.gov (United States)

    Pell, Gaby S; Lewis, David P; Branch, Craig A

    2003-02-01

    Accurate quantification of perfusion with the ADC techniques requires the suppression of the majority of the intravascular signal. This is normally achieved with the use of diffusion gradients. The TurboFLASH sequence with its ultrashort repetition times is not readily amenable to this scheme. This report demonstrates the implementation of a modified TurboFLASH sequence for FAIR imaging. Intravascular suppression is achieved with a modified preparation period that includes a driven equilibrium Fourier transform (DEFT) combination of 90 degrees-180 degrees-90 degrees hard RF pulses subsequent to the inversion delay. These pulses rotate the perfusion-prepared magnetization into the transverse plane where it can experience the suitably placed diffusion gradients before being returned to the longitudinal direction by the second 90 degrees pulse. A value of b = 20-30 s/mm(2) was thereby found to suppress the majority of the intravascular signal. For single-slice perfusion imaging, quantification is only slightly modified. The technique can be readily extended to multislice acquisition if the evolving flow signal after the DEFT preparation is considered. An advantage of the modified preparation scheme is evident in the multislice FAIR images by the preservation of the sign of the magnetization difference. Copyright 2003 Wiley-Liss, Inc.

  7. Measurements of $t\\overline{t}$ Spin Correlations in CMS

    CERN Document Server

    Beernaert, Kelly Simone

    2014-01-01

    We present an overview of the measurements of $t\\bar{t}$ spin correlations in the CMS Collaboration. We present two analyses both in the dilepton channel using proton-proton collisions at $\\sqrt{s}\\, =\\, 7$ TeV based on an integrated luminosity of 5.0 fb$^{-1}$. The spin correlations and polarization are measured using angular asymmetries. The results are consistent with unpolarized top quarks and Standard Model spin correlation. The second analysis sets a limit on the real part of the top-quark chromo-magnetic dipole moment of $-0.043\\, <\\, Re({\\hat{\\mu}}_{t})\\, <\\, 0.117$ at $95\\,%$ confidence level through the measured azimuthal angle difference between the two charged leptons from $t\\bar{t}$ production.

  8. Cardiac T2-mapping using a fast gradient echo spin echo sequence - first in vitro and in vivo experience

    OpenAIRE

    Baessler, Bettina; Schaarschmidt, Frank; Stehning, Christian; Schnackenburg, Bernhard; Maintz, David; Bunck, Alexander C.

    2015-01-01

    Background: The aim of this study was the evaluation of a fast Gradient Spin Echo Technique (GraSE) for cardiac T2-mapping, combining a robust estimation of T2 relaxation times with short acquisition times. The sequence was compared against two previously introduced T2-mapping techniques in a phantom and in vivo. Methods: Phantom experiments were performed at 1.5 T using a commercially available cylindrical gel phantom. Three different T2-mapping techniques were compared: a Multi Echo Spin Ec...

  9. Utility of two types of MR cisternography for patency evaluation of aqueduct and third ventriculostomy site: Three dimentsional sagittal fast spin echo sequence and steady-state coherent fast gradient echo sequence

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jung Hyun; Kim, Eun Hee; Park, Jong Bin; Kim, Jae Hyoung; Choi, Byung Se; Jung, Cheol Kyu; Bae, Yun Jung; Lee, Kyung Mi [Dept. of Radiology, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2015-07-15

    We aimed to evaluate the utility of two types of MR cisternography [fast spin echo sequence and steady-state coherent gradient echo (GRE) sequence] in addition to phase contrast-cine imaging (PC-cine), for assessing patency at the aqueduct and third ventriculostomy site. 43 patients (35 patients with suspected aqueductal stenosis and 8 patients with third ventriculostomy) were retrospectively analyzed. PC-cine, 3 dimensional sagittal fast spin echo sequence [driven-equilibrium imaging (DRIVE) or volumetric isotrophic T2-weighted acquisition (T2 VISTA)] and steady-state coherent fast GRE sequence (balanced turbo field echo; bTFE) imaging were performed in all patients. The patency of the aqueduct or third ventriculostomy site was scored. Some pitfalls of each sequence were also analyzed in individual cases. 93% of all cases showed consistent scores in PC-cine, DRIVE/T2 VISTA, and bTFE imaging. DRIVE/T2 VISTA imaging provided functional information of cerebrospinal fluid flow with flow-related artifacts, while bTFE imaging allowed direct visualization of the aqueduct or ventriculostomy site. However, evaluation of anatomical structures was difficult in three cases with strong flow-related artifacts on DRIVE/T2 VISTA and in 2 cases with susceptibility artifacts on bTFE. Both DRIVE/T2 VISTA and bTFE imaging have complementary roles in evaluating the patency of the aqueduct and 3rd ventriculostomy site.

  10. Utility of two types of MR cisternography for patency evaluation of aqueduct and third ventriculostomy site: Three dimentsional sagittal fast spin echo sequence and steady-state coherent fast gradient echo sequence

    International Nuclear Information System (INIS)

    Park, Jung Hyun; Kim, Eun Hee; Park, Jong Bin; Kim, Jae Hyoung; Choi, Byung Se; Jung, Cheol Kyu; Bae, Yun Jung; Lee, Kyung Mi

    2015-01-01

    We aimed to evaluate the utility of two types of MR cisternography [fast spin echo sequence and steady-state coherent gradient echo (GRE) sequence] in addition to phase contrast-cine imaging (PC-cine), for assessing patency at the aqueduct and third ventriculostomy site. 43 patients (35 patients with suspected aqueductal stenosis and 8 patients with third ventriculostomy) were retrospectively analyzed. PC-cine, 3 dimensional sagittal fast spin echo sequence [driven-equilibrium imaging (DRIVE) or volumetric isotrophic T2-weighted acquisition (T2 VISTA)] and steady-state coherent fast GRE sequence (balanced turbo field echo; bTFE) imaging were performed in all patients. The patency of the aqueduct or third ventriculostomy site was scored. Some pitfalls of each sequence were also analyzed in individual cases. 93% of all cases showed consistent scores in PC-cine, DRIVE/T2 VISTA, and bTFE imaging. DRIVE/T2 VISTA imaging provided functional information of cerebrospinal fluid flow with flow-related artifacts, while bTFE imaging allowed direct visualization of the aqueduct or ventriculostomy site. However, evaluation of anatomical structures was difficult in three cases with strong flow-related artifacts on DRIVE/T2 VISTA and in 2 cases with susceptibility artifacts on bTFE. Both DRIVE/T2 VISTA and bTFE imaging have complementary roles in evaluating the patency of the aqueduct and 3rd ventriculostomy site

  11. Value of different MR techniques in diagnosis of degenerative disorders of the hyaline cartilage - in vitro study on 50 joint specimens of the knee with 1.5 T; Vergleich von verschiedenen MRT-Techniken in der Diagnose von degenerativen Knorpelerkrankungen - in-vitro-Studie an 50 Gelenkpraeparaten des Knies bei 1,5 T

    Energy Technology Data Exchange (ETDEWEB)

    Bachmann, G. [Klinikum der Univ. Giessen (Germany). Abt. Diagnostische Radiologie; Heinrichs, C. [Klinikum der Univ. Giessen (Germany). Inst. fuer Pathologie; Juergensen, I. [Klinikum der Univ. Giessen (Germany). Orthopaedische Klinik; Rominger, M. [Klinikum der Univ. Giessen (Germany). Abt. Diagnostische Radiologie; Scheiter, A. [Klinikum der Univ. Giessen (Germany). Abt. Diagnostische Radiologie; Rau, W.S. [Klinikum der Univ. Giessen (Germany). Abt. Diagnostische Radiologie

    1997-05-01

    Purpose: An experimental study was performed on joint specimens of the knee to assess the advantages and disadvantages of 14 generally available sequences in cartilage imaging. Methods: Each of the 50 surgically exposed cadaveric joints of the knee was examined by the following sequences: T{sub 1}, proton- and T{sub 2} weighted spin echo(SE) sequences, proton- and T{sub 2} weighted Turbo-SE, T{sub 1} weighted SE with fat suppression, MTC combined with T{sub 1}-weighted SE and T{sub 2} weighted FLASH-2 D, STIR, FISP-3 D, FLASH-3 D (with fat suppression), and MR arthrography. We assessed the image quality by a scale, signal to noise-ratio of cartilage and joint fluid, and the accuracy in detection of cartilage lesions. Pathology and arthroscopy were reference methods to MRI, and demonstrated grade 1-4 lesions on 186 of 300 joint facettes. Results: Advanced stages of cartilage lesions (65 grade 3 and 4 lesions) were detected by standard SE sequences in 67-94%. Application of volume techniques (FISP-3 D, FLASH-3 D), high definition matrix (512 pixel), MTC with FLASH-2 D and MR-arthrography improved the sensitivity up to 82-100%. Superficial lesions (65 grade 2 lesions) were demonstrated in 3-38%, and on MR arthrography in 45%. Structural changes (56 Grade 1 lesions) were recorded on MRI in only 10%. Conclusions: With regard to standard SE sequences, the detectability of cartilage lesions can be improved by techniques that use 512 matrices, selective cartilage imaging, and volume acquisition. (orig.) [Deutsch] Ziel: In einer experimentellen Studie an Gelenkpraeparaten des Knies wurden die Vor- und Nachteile von 14 allgemein verfuegbaren MRT-Sequenzen in der Knorpeldiagnostik dargestellt. Methode: 50 chirurgisch exstirpierte Kniegelenkpraeparate wurden nacheinander mit folgenden Techniken untersucht: Klassische Spin-Echo(SE)-Sequenz in T{sub 1}-, Protonen- und T{sub 2}-Wichtung, Turbo-SE in Protonen- und T{sub 2}-Wichtung, Fettsuppression mit T{sub 1}-gew. SE, MTC in

  12. Fusion of High b-valve diffusion-weighted and T2-weighted MR images improves identification of lymph nodes in the pelvis

    International Nuclear Information System (INIS)

    Mir, N.; Sohaib, S.A.; Collins, D.; Koh, D.M.

    2010-01-01

    Full text: Accurate identification of lymph nodes facilities nodal assessment by size, morphological or MR lymphographic criteria. We compared the MR detection of lymph nodes in patients with pelvic cancers using T2-weighted imaging, and fusion of diffusion-weighted imaging (OWl) and T2-weighted imaging. Twenty patients with pelvic tumours underwent 5-mm axial T2-weighted and OWl (b-values 0-750 s/mm 2 ) on a L 5T system. Fusion images of b = 750 s/mm 2 diffusion-weighted MR and T2-weighted images were created. Two radiologists evaluated in consensus the T2-weighted images and fusion images independently. For each image set, the location and diameter of pelvic nodes were recorded, and nodal visibility was scored using a 4-point scale (0-3). Nodal visualisation was compared using Relative to an Identified Distribution (RIDIT) analysis. The mean RIDIT score describes the probability that a randomly selected node will be better visualised relative to the other image set. One hundred fourteen pelvic nodes (mean 5.9 mm; 2-10 mm) were identified on T2-weighted images and 161 nodes (mean 4.3 mm; 2-10 mm) on fusion images. Using fusion images, 47 additional nodes were detected compared with T2-weighted images alone (eight external iliac, 24 inguinal, 12 obturator, two peri-rectal, one presacral). Nodes detected only on fusion images were 2-9 mm (mean 3.7 mm). Nodal visualisation was better using fusion images compared with T2-weighted images (mean RIDIT score 0.689 vs 0.302). Fusion of diffusion-weighted MR with T2-weighted images improves identification of pelvic lymph nodes compared with T2-weighted images alone. The improved nodal identification may aid treatment planning and further nodal characterisation.

  13. Methods of fetal MR: beyond T2-weighted imaging

    International Nuclear Information System (INIS)

    Brugger, Peter C.; Stuhr, Fritz; Lindner, Christian; Prayer, Daniela

    2006-01-01

    The present work reviews the basic methods of performing fetal magnetic resonance imaging (MRI). Since fetal MRI differs in many respects from a postnatal study, several factors have to be taken into account to achieve satisfying image quality. Image quality depends on adequate positioning of the pregnant woman in the magnet, use of appropriate coils and the selection of sequences. Ultrafast T2-weighted sequences are regarded as the mainstay of fetal MR-imaging. However, additional sequences, such as T1-weighted images, diffusion-weighted images, echoplanar imaging may provide further information, especially in extra- central-nervous system regions of the fetal body

  14. Methods of fetal MR: beyond T2-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Brugger, Peter C. [Center of Anatomy and Cell Biology, Integrative Morphology Group, Medical University of Vienna, Waehringerstrasse 13, 1090 Vienna (Austria)]. E-mail: peter.brugger@meduniwien.ac.at; Stuhr, Fritz [Department of Radiology, Medical University of Vienna, Waehringerguertel 18-20, 1090 Vienna (Austria); Lindner, Christian [Department of Radiology, Medical University of Vienna, Waehringerguertel 18-20, 1090 Vienna (Austria); Prayer, Daniela [Department of Radiology, Medical University of Vienna, Waehringerguertel 18-20, 1090 Vienna (Austria)

    2006-02-15

    The present work reviews the basic methods of performing fetal magnetic resonance imaging (MRI). Since fetal MRI differs in many respects from a postnatal study, several factors have to be taken into account to achieve satisfying image quality. Image quality depends on adequate positioning of the pregnant woman in the magnet, use of appropriate coils and the selection of sequences. Ultrafast T2-weighted sequences are regarded as the mainstay of fetal MR-imaging. However, additional sequences, such as T1-weighted images, diffusion-weighted images, echoplanar imaging may provide further information, especially in extra- central-nervous system regions of the fetal body.

  15. The appearances of oesophageal carcinoma demonstrated on high-resolution, T2-weighted MRI, with histopathological correlation

    International Nuclear Information System (INIS)

    Riddell, A.M.; Allum, W.H.; Thompson, J.N.; Wotherspoon, A.C.; Richardson, C.; Brown, G.

    2007-01-01

    This paper describes the spectrum of imaging features of oesophageal adenocarcinoma seen using high-resolution T2-weighted (T2W) magnetic resonance imaging (MRI). Thirty-nine patients with biopsy-proven oesophageal adenocarcinoma were scanned using an external surface coil. A sagittal T2W sequence was used to localise the tumour and to plan axial images perpendicular to the tumour. Fast spin-echo (FSE) T2W axial sequence parameters were: TR/TE, 3,300-5,000 ms/120-80 ms; field of view (FOV) 225 mm, matrix 176 x 512(reconstructed) mm to 256 x 224 mm, giving an in-plane resolution of between 1.28 x 0.44 mm and 0.88 x 1.00 mm, with 3-mm slice thickness. Thirty-three patients underwent resection and the MR images were compared with the histological whole-mount sections. There were four T1, 12 T2, and 17 T3 tumours. The T2W high-resolution MRI sequences produced detailed images of the oesophageal wall and surrounding structures. Analysis of the imaging appearances for different tumour T stages enabled the development of imaging criteria for local staging of oesophageal cancer using high-resolution MRI. Our study illustrates the spectrum of appearances of oesophageal cancer on T2W high-resolution MRI, and using the criteria established in this study, demonstrates the potential of this technique as an alternative non-invasive method for local staging for oesophageal cancer. (orig.)

  16. Comparison between FLAIR images and T2-weighted fast spin-echo images of cerebral territory and lacunar infarction

    International Nuclear Information System (INIS)

    Paeng, Mi Hye; Choi, Hye-Young; Lim, Soo Mee; Lee, Jung Sik

    2003-01-01

    To assess the significance of fluid-attenuated inversion recovery (FLAIR) magnetic resonance (MR) imaging in the diagnosis of intracranial infarctions and to find out differential points between central lacunar infarctions and perivascular spaces. We consecutively selected 25 cases of territorial infarction in 20 patients, 37 cases of central infarction in 40 patients, and 30 patients with perivascular space. Signal intensity and lesion conspicuity were analyzed and compared between FLAIR and FSE T2-weighted images, and differences in signal intensity between central infarction and perivascular spaces were determined. Lesion conspicuity for FLAIR was better than for T2-weighted images in 12 and 15, worse in 4 and 24, and similar in 9 and 16 of territorial and central infarctions, respectively. In nine cases of territorial and one case of central infarction, there was associated hemorrhage. At FLAIR imaging, perivascular spaces showed a fine round low signal without a peripheral high signal rim in 17 patients but no demonstrable signals in 15. Differential diagnosis of perivascular spaces and central infarction was thus not difficult. FLAIR MRI was useful in the diagnosis of infarctions and in differentiating between central small lacular infarctions and perivascular spaces

  17. Magnetic resonance imaging metallic artifact of commonly encountered surgical implants and foreign material.

    Science.gov (United States)

    Sutherland-Smith, James; Tilley, Brenda

    2012-01-01

    Magnetic resonance imaging (MRI) artifacts secondary to metallic implants and foreign bodies are well described. Herein, we provide quantitative data from veterinary implants including total hip arthroplasty implants, cranial cruciate repair implants, surgical screws, a skin staple, ligation clips, an identification microchip, ameroid constrictor, and potential foreign bodies including air gun and BB projectiles and a sewing needle. The objects were scanned in a gelatin phantom with plastic grid using standardized T2-weighted turbo-spin echo (TSE), T1-weighted spin echo, and T2*-weighted gradient recalled echo (GRE) image acquisitions at 1.5 T. Maximum linear dimensions and areas of signal voiding and grid distortion were calculated using a DICOM workstation for each sequence and object. Artifact severity was similar between the T2-weighted TSE and T1-weighted images, while the T2*-weighted images were most susceptible to artifact. Metal type influenced artifact size with the largest artifacts arising from steel objects followed by surgical stainless steel, titanium, and lead. For animals with metallic surgical implants or foreign bodies, the quantification of the artifact size will help guide clinicians on the viability of MRI. © 2012 Veterinary Radiology & Ultrasound.

  18. Comparative study of fast T 2-weighted images using respiratory triggered, breath-hold, fat suppression and phased array multi coil for liver evaluation by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Abbehusen, Cristiane L.; D'Ippolito, Giuseppe; Palacio, Glaucia A.S.; Szejnfeld, Jacob

    2003-01-01

    The objective of this study was to compare both qualitatively and quantitatively six T 2-weighted turbo spin-echo sequences varying the respiratory compensation technique, associating or not fat tissue suppression and using different types of coils. We performed a prospective study of 71 consecutive patients that were submitted to MRI of the liver using a 1.5 T magnet. The six following pulse sequences were used: fat-suppressed respiratory triggered with conventional body coil; breath-hold fat-suppressed with conventional body coil; non-suppressed respiratory triggered with conventional body coil; breath-hold non fat-suppressed with conventional body coil; fat-suppressed respiratory triggered with phased-array multi coil; breath-hold fat-suppressed with phased-array multi coil. Images were analyzed quantitatively by measuring the signal-to-noise ratios and qualitatively by evaluating the sharpness of hepatic contours, visibility of intrahepatic vessels and other segmental landmarks, and the presence of artifacts. Results: the qualitative analysis showed that the mean values obtained with the six sequences were 7.8, 4.6, 7.9, 5.2, 6.7 and 4.6 respectively. The respiratory-triggered sequences were better than the breath-hold sequences in both qualitative and quantitative analysis (p < 0.001). No significant differences in the values of signal-to-noise ratios and in overall image quality were found between the sequences with and without fat suppression (p . 0.05). The sequences using the body coil were similar in terms of image quality (p . 0.05) and better regarding signal-to-noise ratios than those obtained with the phased=array multi coil (p ,0.001). Our qualitative and quantitative results suggest that the best MRI sequences for the valuation of the liver are the sequences with respiratory triggering using a conventional body coil, with or without fat suppression. (author)

  19. MR imaging of cranial nerve lesions using six different high-resolution T1- and T2(*)-weighted 3D and 2D sequences

    Energy Technology Data Exchange (ETDEWEB)

    Seitz, J.; Held, P.; Strotzer, M.; Voelk, M.; Nitz, W.R.; Dorenbeck, U.; Feuerbach, S. [Univ. Hospital of Regensburg (Germany). Dept. of Diagnostic Radiology; Stamato, S. [Univ. of California, San Diego, CA (United States). Dept. of Radiology

    2002-07-01

    Purpose: To find a suitable high-resolution MR protocol for the visualization of lesions of all 12 cranial nerves. Material and Methods: Thirty-eight pathologically changed cranial nerves (17 patients) were studied with MR imaging at 1.5T using 3D T2*-weighted CISS, T1-weighted 3D MP-RAGE (without and with i.v. contrast medium), T2-weighted 3D TSE, T2-weighted 2D TSE and T1-weighted fat saturation 2D TSE sequences. Visibility of the 38 lesions of the 12 cranial nerves in each sequence was evaluated by consensus of two radiologists using an evaluation scale from 1 (excellently visible) to 4 (not visible). Results: The 3D CISS sequence provided the best resolution of the cranial nerves and their lesions when surrounded by CSF. In nerves which were not surrounded by CSF, the 2D T1-weighted contrast-enhanced fat suppression technique was the best sequence. Conclusions: A combination of 3D CISS, the 2D T1-weighted fat suppressed sequence and a 3D contrast-enhanced MP-RAGE proved to be the most useful sequence to visualize all lesions of the cranial nerves. For the determination of enhancement, an additional 3D MP-RAGE sequence without contrast medium is required. This sequence is also very sensitive for the detection of hemorrhage.

  20. MR imaging of cranial nerve lesions using six different high-resolution T1- and T2(*)-weighted 3D and 2D sequences

    International Nuclear Information System (INIS)

    Seitz, J.; Held, P.; Strotzer, M.; Voelk, M.; Nitz, W.R.; Dorenbeck, U.; Feuerbach, S.; Stamato, S.

    2002-01-01

    Purpose: To find a suitable high-resolution MR protocol for the visualization of lesions of all 12 cranial nerves. Material and Methods: Thirty-eight pathologically changed cranial nerves (17 patients) were studied with MR imaging at 1.5T using 3D T2*-weighted CISS, T1-weighted 3D MP-RAGE (without and with i.v. contrast medium), T2-weighted 3D TSE, T2-weighted 2D TSE and T1-weighted fat saturation 2D TSE sequences. Visibility of the 38 lesions of the 12 cranial nerves in each sequence was evaluated by consensus of two radiologists using an evaluation scale from 1 (excellently visible) to 4 (not visible). Results: The 3D CISS sequence provided the best resolution of the cranial nerves and their lesions when surrounded by CSF. In nerves which were not surrounded by CSF, the 2D T1-weighted contrast-enhanced fat suppression technique was the best sequence. Conclusions: A combination of 3D CISS, the 2D T1-weighted fat suppressed sequence and a 3D contrast-enhanced MP-RAGE proved to be the most useful sequence to visualize all lesions of the cranial nerves. For the determination of enhancement, an additional 3D MP-RAGE sequence without contrast medium is required. This sequence is also very sensitive for the detection of hemorrhage

  1. Imaging of pediatric great vessel stents: Computed tomography or magnetic resonance imaging?

    Directory of Open Access Journals (Sweden)

    A M den Harder

    Full Text Available Complications might occur after great vessel stent implantation in children. Therefore follow-up using imaging is warranted.To determine the optimal imaging modality for the assessment of stents used to treat great vessel obstructions in children.Five different large vessel stents were evaluated in an in-vitro setting. All stents were expanded to the maximal vendor recommended diameter (20mm; n = 4 or 10mm; n = 1, placed in an anthropomorphic chest phantom and imaged with a 256-slice CT-scanner. MRI images were acquired at 1.5T using a multi-slice T2-weighted turbo spin echo, an RF-spoiled three-dimensional T1-weighted Fast Field Echo and a balanced turbo field echo 3D sequence. Two blinded observers assessed stent lumen visibility (measured diameter/true diameter *100% in the center and at the outlets of the stent. Reproducibility of diameter measurements was evaluated using the intraclass correlation coefficient for reliability and 95% limits of agreement for agreement analysis.Median stent lumen visibility was 88 (IQR 86-90% with CT for all stents at both the center and outlets. With MRI, the T2-weighted turbo spin echo sequence was preferred which resulted in 82 (78-84% stent lumen visibility. Interobserver reliability and agreement was good for both CT (ICC 0.997, mean difference -0.51 [-1.07-0.05] mm and MRI measurements (ICC 0.951, mean difference -0.05 [-2.52 --2.41] mm.Good in-stent lumen visibility was achievable in this in-vitro study with both CT and MRI in different great vessel stents. Overall reliability was good with clinical acceptable limits of agreement for both CT and MRI. However, common conditions such as in-stent stenosis and associated aneurysms were not tested in this in-vitro study, limiting the value of the in-vitro study.

  2. Imaging of pediatric great vessel stents: Computed tomography or magnetic resonance imaging?

    Science.gov (United States)

    den Harder, A M; Suchá, D; van Hamersvelt, R W; Budde, R P J; de Jong, P A; Schilham, A M R; Bos, C; Breur, J M P J; Leiner, T

    2017-01-01

    Complications might occur after great vessel stent implantation in children. Therefore follow-up using imaging is warranted. To determine the optimal imaging modality for the assessment of stents used to treat great vessel obstructions in children. Five different large vessel stents were evaluated in an in-vitro setting. All stents were expanded to the maximal vendor recommended diameter (20mm; n = 4 or 10mm; n = 1), placed in an anthropomorphic chest phantom and imaged with a 256-slice CT-scanner. MRI images were acquired at 1.5T using a multi-slice T2-weighted turbo spin echo, an RF-spoiled three-dimensional T1-weighted Fast Field Echo and a balanced turbo field echo 3D sequence. Two blinded observers assessed stent lumen visibility (measured diameter/true diameter *100%) in the center and at the outlets of the stent. Reproducibility of diameter measurements was evaluated using the intraclass correlation coefficient for reliability and 95% limits of agreement for agreement analysis. Median stent lumen visibility was 88 (IQR 86-90)% with CT for all stents at both the center and outlets. With MRI, the T2-weighted turbo spin echo sequence was preferred which resulted in 82 (78-84%) stent lumen visibility. Interobserver reliability and agreement was good for both CT (ICC 0.997, mean difference -0.51 [-1.07-0.05] mm) and MRI measurements (ICC 0.951, mean difference -0.05 [-2.52 --2.41] mm). Good in-stent lumen visibility was achievable in this in-vitro study with both CT and MRI in different great vessel stents. Overall reliability was good with clinical acceptable limits of agreement for both CT and MRI. However, common conditions such as in-stent stenosis and associated aneurysms were not tested in this in-vitro study, limiting the value of the in-vitro study.

  3. T violating neutron spin rotation asymmetry

    International Nuclear Information System (INIS)

    Masuda, Yasushiro.

    1993-01-01

    A new experiment on T-violation is proposed, where a spin-rotating-neutron transmission through a polarized nuclear target is measuered. The method to control the neutron spin is discussed for the new T-violation experiment. The present method has possibility to provide us more accurate T-violation information than the neutron EDM measurement

  4. Detection of prostate carcinomas with T1-weighted dynamic contrast-enhanced MRI. Value of two-compartment model

    International Nuclear Information System (INIS)

    Kiessling, F.; Lichy, M.; Farhan, N.; Delorme, S.; Kauczor, H.U.; Grobholz, R.; Heilmann, M.; Michel, M.S.; Trojan, L.; Werner, A.; Rabe, J.; Schlemmer, H.P.

    2003-01-01

    Aim The suitability of dynamic parameters of the two-compartment model for detecting prostate carcinomas and its correlation with tumor microvascular density were evaluated. The study included 43 patients with biopsy-proven prostate carcinoma: 28 were examined by 1.0-T MRI (Turbo-FLASH) and 15 by 1.5-T MRI (FLASH) with infusion of 0.1 mmol/kg Gd-DTPA. Signal time curves were parametrized with an open two-compartment model in amplitude and exchange rate constants (k ep ).The microvascular density of resected prostate carcinomas was determined. The microvascular density in the tumors was significantly higher than in the adjacent healthy prostate tissue and correlated in both sequences with k ep . Prostate carcinomas of the peripheral zone were demarcated by amplitude and k ep . In the Turbo-FLASH sequence there was a significant difference between the tumor tissue and healthy peripheral zone in terms of k ep and in the FLASH sequence in terms of amplitude. Prostate carcinomas can be visualized with dynamic T1-weighted MR sequences using a two-compartment model. Moreover, the parameter k ep reveals the microvascular density in the tumor and can thus provide valuable clinical information for characterizing the tumors. (orig.) [de

  5. MR fingerprinting for rapid quantification of myocardial T1 , T2 , and proton spin density.

    Science.gov (United States)

    Hamilton, Jesse I; Jiang, Yun; Chen, Yong; Ma, Dan; Lo, Wei-Ching; Griswold, Mark; Seiberlich, Nicole

    2017-04-01

    To introduce a two-dimensional MR fingerprinting (MRF) technique for quantification of T 1 , T 2 , and M 0 in myocardium. An electrocardiograph-triggered MRF method is introduced for mapping myocardial T 1 , T 2 , and M 0 during a single breath-hold in as short as four heartbeats. The pulse sequence uses variable flip angles, repetition times, inversion recovery times, and T 2 preparation dephasing times. A dictionary of possible signal evolutions is simulated for each scan that incorporates the subject's unique variations in heart rate. Aspects of the sequence design were explored in simulations, and the accuracy and precision of cardiac MRF were assessed in a phantom study. In vivo imaging was performed at 3 Tesla in 11 volunteers to generate native parametric maps. T 1 and T 2 measurements from the proposed cardiac MRF sequence correlated well with standard spin echo measurements in the phantom study (R 2  > 0.99). A Bland-Altman analysis revealed good agreement for myocardial T 1 measurements between MRF and MOLLI (bias 1 ms, 95% limits of agreement -72 to 72 ms) and T 2 measurements between MRF and T 2 -prepared balanced steady-state free precession (bias, -2.6 ms; 95% limits of agreement, -8.5 to 3.3 ms). MRF can provide quantitative single slice T 1 , T 2 , and M 0 maps in the heart within a single breath-hold. Magn Reson Med 77:1446-1458, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  6. First-pass myocardial perfusion MR imaging with gadolinium-enhanced turbo FLASH

    International Nuclear Information System (INIS)

    Teresi, L.M.; Smith, C.; Messenger, J.; Watanabe, A.; Herbst, M.; O'Sullivan, R.M.; Lee, R.; Remer, J.; Rappaport, A.; Bradley, W.G.

    1990-01-01

    This paper determines the efficacy of MR first-pass myocardial perfusion imaging using gadolinium-enhanced Turbo--fast low-angle shot (FLASH) ultrafast imaging combined with MR systolic wall thickening data for the determination of myocardial viability. Five normal volunteers and five patients with remote myocardial infarction were studied on a 1.5-T imaging system (Siemans, Ehrlangen, NJ). Turbo-FLASH imaging utilized a 180 degrees inversion pulse followed by a rapid gradient-echo sequence (TI 400 msec, TE2 msec, TR 4.9 msec, FA 8 degrees) with a complete 64 x 64 matrix image (300 mm FOV) being acquired in 300 msec. First-pass myocardial perfusion imaging was performed in the short-axis and long-axis oblique projections with a concantenated series of Turbo-FLASH images triggered to end-systole acquired immediately before and during a rapid bolus injection of 5cc gadolinium-DTPA

  7. High signals in the uterine cervix on T2-weighted MRI sequences

    International Nuclear Information System (INIS)

    Graef, De M.; Karam, R.; Daclin, P.Y.; Rouanet, J.P.; Juhan, V.; Maubon, A.J.

    2003-01-01

    The aim of this pictorial review was to illustrate the normal cervix appearance on T2-weighted images, and give a review of common or less common disorders of the uterine cervix that appear as high signal intensity lesions on T2-weighted sequences. Numerous aetiologies dominated by cervical cancer are reviewed and discussed. This gamut is obviously incomplete; however, radiologists who perform MR women's imaging should perform T2-weighted sequences in the sagittal plane regardless of the indication for pelvic MR. Those sequences will diagnose some previously unknown cervical cancers as well as many other unknown cervical or uterine lesions. (orig.)

  8. Intracranial cerebrospinal fluid spaces imaging using a pulse-triggered three-dimensional turbo spin echo MR sequence with variable flip-angle distribution

    International Nuclear Information System (INIS)

    Hodel, Jerome; Silvera, Jonathan; Bekaert, Olivier; Decq, Philippe; Rahmouni, Alain; Bastuji-Garin, Sylvie; Vignaud, Alexandre; Petit, Eric; Durning, Bruno

    2011-01-01

    To assess the three-dimensional turbo spin echo with variable flip-angle distribution magnetic resonance sequence (SPACE: Sampling Perfection with Application optimised Contrast using different flip-angle Evolution) for the imaging of intracranial cerebrospinal fluid (CSF) spaces. We prospectively investigated 18 healthy volunteers and 25 patients, 20 with communicating hydrocephalus (CH), five with non-communicating hydrocephalus (NCH), using the SPACE sequence at 1.5T. Volume rendering views of both intracranial and ventricular CSF were obtained for all patients and volunteers. The subarachnoid CSF distribution was qualitatively evaluated on volume rendering views using a four-point scale. The CSF volumes within total, ventricular and subarachnoid spaces were calculated as well as the ratio between ventricular and subarachnoid CSF volumes. Three different patterns of subarachnoid CSF distribution were observed. In healthy volunteers we found narrowed CSF spaces within the occipital aera. A diffuse narrowing of the subarachnoid CSF spaces was observed in patients with NCH whereas patients with CH exhibited narrowed CSF spaces within the high midline convexity. The ratios between ventricular and subarachnoid CSF volumes were significantly different among the volunteers, patients with CH and patients with NCH. The assessment of CSF spaces volume and distribution may help to characterise hydrocephalus. (orig.)

  9. Intracranial cerebrospinal fluid spaces imaging using a pulse-triggered three-dimensional turbo spin echo MR sequence with variable flip-angle distribution

    Energy Technology Data Exchange (ETDEWEB)

    Hodel, Jerome [Unite Analyse et Restauration du Mouvement, UMR-CNRS, 8005 LBM ParisTech Ensam, Paris (France); University Paris Est Creteil (UPEC), Creteil (France); Assistance Publique-Hopitaux de Paris, Paris (France); Hopital Henri Mondor, Department of Neuroradiology, Creteil (France); Hopital Henri Mondor, Creteil (France); Silvera, Jonathan [University Paris Est Creteil (UPEC), Creteil (France); Assistance Publique-Hopitaux de Paris, Paris (France); Hopital Henri Mondor, Department of Neuroradiology, Creteil (France); Bekaert, Olivier; Decq, Philippe [Unite Analyse et Restauration du Mouvement, UMR-CNRS, 8005 LBM ParisTech Ensam, Paris (France); University Paris Est Creteil (UPEC), Creteil (France); Assistance Publique-Hopitaux de Paris, Paris (France); Hopital Henri Mondor, Department of Neurosurgery, Creteil (France); Rahmouni, Alain [University Paris Est Creteil (UPEC), Creteil (France); Assistance Publique-Hopitaux de Paris, Paris (France); Hopital Henri Mondor, Department of Radiology, Creteil (France); Bastuji-Garin, Sylvie [University Paris Est Creteil (UPEC), Creteil (France); Assistance Publique-Hopitaux de Paris, Paris (France); Hopital Henri Mondor, Department of Public Health, Creteil (France); Vignaud, Alexandre [Siemens Healthcare, Saint Denis (France); Petit, Eric; Durning, Bruno [Laboratoire Images Signaux et Systemes Intelligents, UPEC, Creteil (France)

    2011-02-15

    To assess the three-dimensional turbo spin echo with variable flip-angle distribution magnetic resonance sequence (SPACE: Sampling Perfection with Application optimised Contrast using different flip-angle Evolution) for the imaging of intracranial cerebrospinal fluid (CSF) spaces. We prospectively investigated 18 healthy volunteers and 25 patients, 20 with communicating hydrocephalus (CH), five with non-communicating hydrocephalus (NCH), using the SPACE sequence at 1.5T. Volume rendering views of both intracranial and ventricular CSF were obtained for all patients and volunteers. The subarachnoid CSF distribution was qualitatively evaluated on volume rendering views using a four-point scale. The CSF volumes within total, ventricular and subarachnoid spaces were calculated as well as the ratio between ventricular and subarachnoid CSF volumes. Three different patterns of subarachnoid CSF distribution were observed. In healthy volunteers we found narrowed CSF spaces within the occipital aera. A diffuse narrowing of the subarachnoid CSF spaces was observed in patients with NCH whereas patients with CH exhibited narrowed CSF spaces within the high midline convexity. The ratios between ventricular and subarachnoid CSF volumes were significantly different among the volunteers, patients with CH and patients with NCH. The assessment of CSF spaces volume and distribution may help to characterise hydrocephalus. (orig.)

  10. [Comparison of 2D and 3D sequences for MRCP. Clinical value of the different techniques].

    Science.gov (United States)

    Wallnoefer, A M; Herrmann, K A; Beuers, U; Zech, C J; Gourtsoyianni, S; Reiser, M F; Schoenberg, S O

    2005-11-01

    Magnetic resonance cholangio-pancreaticograpy (MRCP) is a non-invasive imaging modality of the pancreatico-biliary system which plays an increasingly important role in the clinical and diagnostic workup of patients with biliary or pancreatic diseases. The present review is designed to give an overview of the currently available and appropriate sequences, their technical background, as well as new developments and their relevance to the various clinical issues and challenges. The impact of the latest technical innovations, such as integrated parallel imaging techniques and navigator-based respiratory triggering, on the diagnostic capacities of MRCP is discussed. In this context, the individual value of RARE, T2w single shot turbo/fast spin echo (SSFSE) and the recently introduced 3D T2w turbo/fast spin echo sequences (T2w 3D-T/FSE) is reviewed. RARE imaging may be preferred in severely ill patients with limitations in cooperation, SSFSE is particularly effective in differentiating benign and malignant stenosis, and 3D-FSE offers additional advantages in the detection of small biliary concrements.

  11. High resolution MR imaging of the anal sphincter using an intravaginal surface coil; Hochaufloesende Magnetresonanztomographie des Analsphinkters mit einer intravaginalen Oberflaechenspule

    Energy Technology Data Exchange (ETDEWEB)

    Mueller-Schimpfle, M. [Radiologische Klinik, Abt. fuer Radiologische Diagnostik, Tuebingen Univ. (Germany); Franz, H. [Frauenklinik, Tuebingen Univ. (Germany); Lobinger, B. [Radiologische Klinik, Abt. fuer Radiologische Diagnostik, Tuebingen Univ. (Germany); Claussen, C.D. [Radiologische Klinik, Abt. fuer Radiologische Diagnostik, Tuebingen Univ. (Germany)

    1995-06-01

    MR imaging was performed using a 1.0 T unit. In 10 females (6 nullipara, one primipara without and three primipara with postpartum faecal incontinence) a surface coil, originally designed for endorectal use, was placed into the vagina. Transverse oblique T{sub 1}-weighted spin echo and double echo turbo spin echo sequences with T{sub 2}- and proton density-weighting were acquired parallel to the puborectal, rectococcygeal and anorectal planes. Three readers analysed the images in consensus. The anatomic structures of the external and internal sphincter as well as the mucosa were differentiated in all cases with a good contrast. The best results were yielded by the proton density weighting. In one case of faecal incontinence a sphincter defect after repair of a complete rupture of the anal sphincter was shown. In another case irregularities in the structure of the external sphincter and perineum were visualised. (orig./MG) [Deutsch] Die Magnetresonanztomographie (MRT) wurde an einem 1,0-Tesla-Geraet durchgefuehrt. Bei 10 Frauen (6 Nulliparae, eine Primipara ohne und drei Primiparae mit postpartaler Stuhlinkontinenz) wurde eine Oberflaechenspule, die urspruenglich zur endorektalen Anwendung konzipiert war, intravaginal eingefuehrt. Es wurden T{sub 1}-gewichtete Spin-Echo-Sequenzen sowie Doppel-Echo-Turbo-Spin-Echo-Sequenzen mit T{sub 2}- und Protonendichtegewichtung parallel zur puborektalen, rektokokzygealen und anorektalen Ebene akquiriert. Drei Auswerter analysierten die Aufnahmen im Konsensmodus. Die anatomischen Strukturen des Musculus sphincter ani externus und internus sowie die Mukosa konnten in allen Faellen gut differenziert werden. Das beste Ergebnis wurde mit der Protonendichte-Gewichtung erzielt. In einem Fall von Stuhlinkontinenz zeigte sich ein kombinierter Defekt des M. sphincter ani internus und externus nach Naht eines Dammrisses III. Grades. In einem weiteren Fall waren Irregularitaeten im Perineum und externen Sphinkteranteil darzustellen. (orig./MG)

  12. Differentiating benign and malignant breast lesions with T2*-weighted first pass perfusion imaging

    International Nuclear Information System (INIS)

    Kvistad, K.A.; Smenes, E.; Haraldseth, O.; Lundgren, S.; Fjoesne, H.E.; Smethurst, H.B.

    1999-01-01

    Purpose: Invasive breast carcinomas and fibroadenomas are often difficult to differentiate in dynamic contrast-enhanced T1-weighted MR imaging of the breast, because both tumors can enhance strongly after contrast injection. The purpose of this study was to evaluate whether the addition of T2*-weighted first pass perfusion imaging can increase the differentiation of malignant from benign lesions. Material and Methods: Nine patients with invasive carcinomas and 10 patients with contrast enhancing fibroadenomas were examined by a dynamic contrast-enhanced T1-weighted 3D sequence immediately followed by a single slice T2*-weighted first pass perfusion sequence positioned in the contrast-enhancing lesion. Results: The carcinomas and the fibroadenomas were impossible to differentiate based on the contrast enhancement characteristics in the T1-weighted sequence. The signal loss in the T2*-weighted perfusion sequence was significantly stronger in the carcinomas than in the fibroadenomas (p=0.0004). Conclusion: Addition of a T2*-weighted first pass perfusion sequence with a high temporal resolution can probably increase the differentiation of fibroadenomas from invasive carcinomas in contrast-enhanced MR imaging of the breast. (orig.)

  13. A Prospective Evaluation of T2-Weighted First-Pass Perfusion MR Imaging In Diagnosing Breast Neoplasms

    Institute of Scientific and Technical Information of China (English)

    XiaoJuanUu; RenyouZhai; TaoJiang; LiWang

    2004-01-01

    OBJECTIVE To compare the results from breast cancer patients who undergo T2-weighted first-pass perfusion imaging after dynamic contrast-enhanced T1-weighted imaging during the same examination,and to evaluate if T2-weighted imaging can provide additional diagnostic information over that obtained with Tl-weiahted imaaina.METHODS Twenty-nine patients with breast lesions verified by pathology (benign 12, malignant 17) underwent MR imaging with dynamic contrast-enhanced Tl-weighted imaging of the entire breasts,immediately followed by 6-sections of T2-weighted first-pass perfusion imaging of the lesions. The diagnostic indices were acquired by individual 3D Tl-weighted enhancement rate criterion and the T2 signalintensity loss rate criterion. The sensitivity and specificity were calculated and the 2 methods were compared.RESULTS With the dynamic contrast-enhanced T1-weighted imaging there was a significant differences breast lesions (t=2.563, P=0.016)overlap between the signal intensitybetween the benign and malignant However we found a considerable increase in the carcinomas and thatin the benign lesions, for a sensitivity of 94% and a specificity of 25%.With T2-weighted first-pass perfusion imaging, there was a very significant difference between the benign and malignant breast lesions(t=4.777,P<0.001), and the overlap between the signal intensity decrease in the carcinomas and that of the benign lesions on the T2-weighted images was less pronounced than the overlap in the T1-weighted images, for a sensitivity of 88% and a specificity of 75%.CONCLUSION T2-weighted first-pass perfusion imaging may help differentiate between benign and malignant breast lesions with a higher level of specificity. The combination of T1-weighted and T2-weighted imaging is feasible in a single patient examination and may improve breast MR imaging.

  14. Myometrial invasion in endometrial cancer: diagnostic performance of diffusion-weighted MR imaging at 1.5-T

    International Nuclear Information System (INIS)

    Rechichi, Gilda; Sironi, Sandro; Galimberti, Stefania; Valsecchi, Maria Grazia; Signorelli, Mauro; Perego, Patrizia

    2010-01-01

    To determine the diagnostic accuracy of diffusion-weighted (DW) magnetic resonance (MR) imaging in the preoperative assessment of myometrial invasion by endometrial cancer. In this prospective study, 47 patients with histologically confirmed endometrial cancer underwent preoperative MR imaging and total hysterectomy. The MR protocol included spin-echo multishot T2-weighted, dynamic T1-weighted and DW images acquired with b-values of 0 and 500 s/mm 2 . Myometrial tumour spread was classified as superficial (<50%) or deep (≥50% myometrial thickness). Postoperative histopathological findings served as a reference standard. Indices of diagnostic performance were assessed for each sequence. At histopathological examination, superficial myometrial invasion was found in 34 patients and deep myometrial invasion in 13. In the assessment of tumour invasion, sensitivity, specificity, positive and negative predictive values of T2-weighted images were 92.3%, 76.5%, 60.0% and 96.3%, respectively. The corresponding values for dynamic images were 69.2%, 61.8%, 40.9% and 84.0%, and for DW images 84.6%, 70.6%, 52.4% and 92.3%. T2-weighted and DW imaging proved to be the most accurate techniques for tumour spread determination. DW imaging proved to be accurate in assessing myometrial invasion, and it could replace dynamic imaging as an adjunct to routine T2-weighted imaging for preoperative evaluation of endometrial cancer. (orig.)

  15. 3D T2-weighted imaging to shorten multiparametric prostate MRI protocols.

    Science.gov (United States)

    Polanec, Stephan H; Lazar, Mathias; Wengert, Georg J; Bickel, Hubert; Spick, Claudio; Susani, Martin; Shariat, Shahrokh; Clauser, Paola; Baltzer, Pascal A T

    2018-04-01

    To determine whether 3D acquisitions provide equivalent image quality, lesion delineation quality and PI-RADS v2 performance compared to 2D acquisitions in T2-weighted imaging of the prostate at 3 T. This IRB-approved, prospective study included 150 consecutive patients (mean age 63.7 years, 35-84 years; mean PSA 7.2 ng/ml, 0.4-31.1 ng/ml). Two uroradiologists (R1, R2) independently rated image quality and lesion delineation quality using a five-point ordinal scale and assigned a PI-RADS score for 2D and 3D T2-weighted image data sets. Data were compared using visual grading characteristics (VGC) and receiver operating characteristics (ROC)/area under the curve (AUC) analysis. Image quality was similarly good to excellent for 2D T2w (mean score R1, 4.3 ± 0.81; R2, 4.7 ± 0.83) and 3D T2w (mean score R1, 4.3 ± 0.82; R2, 4.7 ± 0.69), p = 0.269. Lesion delineation was rated good to excellent for 2D (mean score R1, 4.16 ± 0.81; R2, 4.19 ± 0.92) and 3D T2w (R1, 4.19 ± 0.94; R2, 4.27 ± 0.94) without significant differences (p = 0.785). ROC analysis showed an equivalent performance for 2D (AUC 0.580-0.623) and 3D (AUC 0.576-0.629) T2w (p > 0.05, respectively). Three-dimensional acquisitions demonstrated equivalent image and lesion delineation quality, and PI-RADS v2 performance, compared to 2D in T2-weighted imaging of the prostate. Three-dimensional T2-weighted imaging could be used to considerably shorten prostate MRI protocols in clinical practice. • 3D shows equivalent image quality and lesion delineation compared to 2D T2w. • 3D T2w and 2D T2w image acquisition demonstrated comparable diagnostic performance. • Using a single 3D T2w acquisition may shorten the protocol by 40%. • Combined with short DCE, multiparametric protocols of 10 min are feasible.

  16. Deformed Fredkin spin chain with extensive entanglement

    Science.gov (United States)

    Salberger, Olof; Udagawa, Takuma; Zhang, Zhao; Katsura, Hosho; Klich, Israel; Korepin, Vladimir

    2017-06-01

    We introduce a new spin chain which is a deformation of the Fredkin spin chain and has a phase transition between bounded and extensive entanglement entropy scaling. In this chain, spins have a local interaction of three nearest neighbors. The Hamiltonian is frustration-free and its ground state can be described analytically as a weighted superposition of Dyck paths that depends on a deformation parameter t. In the purely spin 1/2 case, whenever t\

  17. Assessment of T2-Weighted Coronal Magnetic Resonance Images in the Investigation of Pituitary Lesions

    International Nuclear Information System (INIS)

    Yuksekkaya, Ruken; Aggunlu, Levent; Oner, Yusuf; Celik, Halil; Akpek, Sergin; Celikyay, Fatih

    2014-01-01

    Magnetic resonance imaging is the most important diagnostic method in the investigation of the pituitary lesions. Our aim is to determine whether T2-weighted coronal images may be helpful in the evaluation of the pituitary gland with suspected pituitary adenomas. One hundred and sixty-seven patients were examined prospectively with T2-weighted coronal and T1-weighted coronal images enhanced with intravenous contrast material. The images were evaluated for the presence, the size, the location, and the ancillary signs including sellar floor erosion or ballooning, infindibulary deviation, convexity of the superior border of the gland, diffuse enlargement of the gland, and the invasion of the cavenous sinuses on both images. In forty-six (28%) patients lesions were revealed on both sequences. In twenty-one (12%) patients the lesions that were revealed on the T1-weighted images were not detected on the T2-weighted images. Positive predictive value, negative predictive value, sensitivity, specificity, and diagnostic accuracy rates of T2-weighted coronal images on the detection of the presence of lesions were 100%, 17.4%, 68.7%, 100%, and 87.4%, respectively. Both T2-weighted coronal and T1-weighted coronal images enhanced with intravenous gadolinium-based contrast material are important in the diagnosis of pituitary adenomas. T2-weighted coronal images could be used as a screening tool for the primary evaluation of the pituitary gland

  18. Mixed spin-3/2 and spin-5/2 Ising system on the Bethe lattice

    International Nuclear Information System (INIS)

    Albayrak, Erhan; Yigit, Ali

    2006-01-01

    In order to study the critical behaviors of the half-integer mixed spin-3/2 and spin-5/2 Blume-Capel Ising ferrimagnetic system, we have used the exact recursion relations on the Bethe lattice. The system was studied for the coordination numbers with q=3, 4, 5 and 6, and the obtained phase diagrams are illustrated on the (kT c /|J|,D A /|J|) plane for constant values of D B /|J|, the reduced crystal field of the sublattice with spin-5/2, and on the (kT c /|J|,D B /|J|) plane for constant values of D A /|J|, the reduced crystal field of the sublattice with spin-3/2, for q=3 only, since the cases corresponding to q=4, 5 and 6 reproduce results similar to the case for q=3. In addition we have also presented the phase diagram with equal strengths of the crystal fields for q=3, 4, 5 and 6. Besides the second- and first-order phase transitions, the system also exhibits compensation temperatures for appropriate values of the crystal fields. In this mixed spin system while the second-order phase transition lines never cut the reduced crystal field axes as in the single spin type spin-3/2 and spin-5/2 Ising models separately, the first-order phase transition lines never connect to the second-order phase transition lines and they end at the critical points, therefore the system does not give any tricritical points. In addition to this, this mixed-spin model exhibits one or two compensation temperatures depending on the values of the crystal fields, as a result the compensation temperature lines show reentrant behavior

  19. The value of diffusion-weighted imaging in combination with T2-weighted imaging for rectal cancer detection

    International Nuclear Information System (INIS)

    Rao Shengxiang; Zeng Mengsu; Chen Caizhong; Li Renchen; Zhang Shujie; Xu Jianming; Hou Yingyong

    2008-01-01

    Objective: To evaluate the clinical value of diffusion-weighted imaging (DWI) in combination with T 2 -weighted imaging (T 2 WI) for the detection of rectal cancer as compared with T 2 WI alone. Materials and methods: Forty-five patients with rectal cancer and 20 without rectal cancer underwent DWI with parallel imaging and T 2 WI on a 1.5 T scanner. Images were independently reviewed by two readers blinded to the results to determine the detectability of rectal cancer. The detectability of T 2 W imaging without and with DW imaging was assessed by means of receiver operating characteristic analysis. The interobserver agreement between the two readers was calculated with kappa statistics. Results: The ROC analysis showed that each of two readers achieved more accurate results with T 2 W imaging combined with DW imaging than with T 2 W imaging alone significantly. The A z values for the two readers for each T 2 WI and T 2 WI combined with DWI were 0.918 versus 0.991 (p = 0.0494), 0.934 versus 0.997 (p = 0.0475), respectively. The values of kappa were 0.934 for T 2 WI and 0.948 for T 2 WI combined with DWI between the two readers. Conclusion: The addition of DW imaging to conventional T 2 W imaging provides better detection of rectal cancer

  20. Algorithm for the generation of nuclear spin species and nuclear spin statistical weights

    International Nuclear Information System (INIS)

    Balasubramanian, K.

    1982-01-01

    A set of algorithms for the computer generation of nuclear spin species and nuclear spin statistical weights potentially useful in molecular spectroscopy is developed. These algorithms generate the nuclear spin species from group structures known as generalized character cycle indices (GCCIs). Thus the required input for these algorithms is just the set of all GCCIs for the symmetry group of the molecule which can be computed easily from the character table. The algorithms are executed and illustrated with examples

  1. SU-F-R-35: Repeatability of Texture Features in T1- and T2-Weighted MR Images

    International Nuclear Information System (INIS)

    Mahon, R; Weiss, E; Karki, K; Hugo, G; Ford, J

    2016-01-01

    Purpose: To evaluate repeatability of lung tumor texture features from inspiration/expiration MR image pairs for potential use in patient specific care models and applications. Repeatability is a desirable and necessary characteristic of features included in such models. Methods: T1-weighted Volumetric Interpolation Breath-Hold Examination (VIBE) and/or T2-weighted MRI scans were acquired for 15 patients with non-small cell lung cancer before and during radiotherapy for a total of 32 and 34 same session inspiration-expiration breath-hold image pairs respectively. Bias correction was applied to the VIBE (VIBE-BC) and T2-weighted (T2-BC) images. Fifty-nine texture features at five wavelet decomposition ratios were extracted from the delineated primary tumor including: histogram(HIST), gray level co-occurrence matrix(GLCM), gray level run length matrix(GLRLM), gray level size zone matrix(GLSZM), and neighborhood gray tone different matrix (NGTDM) based features. Repeatability of the texture features for VIBE, VIBE-BC, T2-weighted, and T2-BC image pairs was evaluated by the concordance correlation coefficient (CCC) between corresponding image pairs, with a value greater than 0.90 indicating repeatability. Results: For the VIBE image pairs, the percentage of repeatable texture features by wavelet ratio was between 20% and 24% of the 59 extracted features; the T2-weighted image pairs exhibited repeatability in the range of 44–49%. The percentage dropped to 10–20% for the VIBE-BC images, and 12–14% for the T2-BC images. In addition, five texture features were found to be repeatable in all four image sets including two GLRLM, two GLZSM, and one NGTDN features. No single texture feature category was repeatable among all three image types; however, certain categories performed more consistently on a per image type basis. Conclusion: We identified repeatable texture features on T1- and T2-weighted MRI scans. These texture features should be further investigated for use

  2. SU-F-R-35: Repeatability of Texture Features in T1- and T2-Weighted MR Images

    Energy Technology Data Exchange (ETDEWEB)

    Mahon, R; Weiss, E; Karki, K; Hugo, G [Virginia Commonwealth University, Richmond, VA (United States); Ford, J [University of Miami Miller School of Medicine, Miami, FL (United States)

    2016-06-15

    Purpose: To evaluate repeatability of lung tumor texture features from inspiration/expiration MR image pairs for potential use in patient specific care models and applications. Repeatability is a desirable and necessary characteristic of features included in such models. Methods: T1-weighted Volumetric Interpolation Breath-Hold Examination (VIBE) and/or T2-weighted MRI scans were acquired for 15 patients with non-small cell lung cancer before and during radiotherapy for a total of 32 and 34 same session inspiration-expiration breath-hold image pairs respectively. Bias correction was applied to the VIBE (VIBE-BC) and T2-weighted (T2-BC) images. Fifty-nine texture features at five wavelet decomposition ratios were extracted from the delineated primary tumor including: histogram(HIST), gray level co-occurrence matrix(GLCM), gray level run length matrix(GLRLM), gray level size zone matrix(GLSZM), and neighborhood gray tone different matrix (NGTDM) based features. Repeatability of the texture features for VIBE, VIBE-BC, T2-weighted, and T2-BC image pairs was evaluated by the concordance correlation coefficient (CCC) between corresponding image pairs, with a value greater than 0.90 indicating repeatability. Results: For the VIBE image pairs, the percentage of repeatable texture features by wavelet ratio was between 20% and 24% of the 59 extracted features; the T2-weighted image pairs exhibited repeatability in the range of 44–49%. The percentage dropped to 10–20% for the VIBE-BC images, and 12–14% for the T2-BC images. In addition, five texture features were found to be repeatable in all four image sets including two GLRLM, two GLZSM, and one NGTDN features. No single texture feature category was repeatable among all three image types; however, certain categories performed more consistently on a per image type basis. Conclusion: We identified repeatable texture features on T1- and T2-weighted MRI scans. These texture features should be further investigated for use

  3. Detection of hyperacute parenchymal hemorrhage of the brain using echo-planar T2{sup *}-weighted and diffusion-weighted MRI

    Energy Technology Data Exchange (ETDEWEB)

    Wiesmann, M. [Dept. of Radiology, Medizinische Universitaet zu Luebeck (Germany); Mayer, T.E.; Yousry, I.; Brueckmann, H. [Dept. of Neuroradiology, Klinikum Grosshadern, Ludwig-Maximilians-Universitaet, Muenchen (Germany); Hamann, G.F. [Dept. of Neurology, Klinikum Grosshadern, Ludwig-Maximilians-Universitaet, Muenchen (Germany)

    2001-05-01

    We investigated the usefulness of echo-planar imaging (EPI) as well as T2{sup *}-weighted and diffusion-weighted MRI (DWI) to identify hyperacute hemorrhage (within 24 h after ictus) in the brain. Seven patients were examined 3.5 to 24 h after onset of symptoms using a whole-body 1.5-T MR system. Two diffusion-weighted sequences were run to obtain isotropic and anisotropic diffusion images. Apparent diffusion coefficients (ADC) were calculated from the isotropic diffusion images. All DWI images as well as the T2*-weighted EPI images showed the hematomas as either discrete, deeply hypointense homogeneous lesions, or as lesions of mixed signal intensity containing hypointense areas. We conclude that even in the early phase after hemorrhage, sufficient amounts of paramagnetic deoxyhemoglobin are present in intracerebral hemorrhages to cause hypointensity on EPI T2{sup *}-weighted and DWI images; thus, use of ultrafast EPI allows identification of intracerebral hemorrhage. (orig.)

  4. NMR studies at high magnetic fields of LiVGe_2O_6, a quasi one-dimensional spin S=1 system

    Science.gov (United States)

    Vonlanthen, P.; Tanaka, K. B.; Clark, W. G.; Gavilano, J. L.; Ott, H. R.; Millet, P.; Mila, F.; Kuhns, P.; Reyes, A. P.; Moulton, W. G.

    2001-03-01

    We report ^7Li NMR studies of LiVGe_2O_6, a quasi one-dimensional spin S=1 system. Our measurements include NMR spectra, the spin-lattice relaxation rate, T_1-1, and the spin-spin relaxation rate, T_2-1, obtained at magnetic fields (B) of 9 and 23 T and temperatures (T) over the range 1.8 - 300 K. The 9 T NMR spectra show a continuous transfer of spectral weight from a paramagnetic phase to an antiferromagnetic one in a narrow temperature range of about 2 K around the transition temperature TN ≈ 25 K. Both phases coexist in this range. Below 10 K, well into the antiferromagnetic phase, the T_1-1 measurements are consistent with electron spin excitations across an energy gap (Δ) with Δ/k_B≈ 14 K at 9 T and 11 K at about 23 T; i.e., applying a large B slightly reduces Δ. Changing B from 9 to 23 T increases TN by 1 K. Thus, TN is influenced only marginally by B up to 23 Tesla. The UCLA part of the work was supported by NSF Grants DMR-9705369 and DMR-0072524.

  5. The gap of the area-weighted Motzkin spin chain is exponentially small

    Science.gov (United States)

    Levine, Lionel; Movassagh, Ramis

    2017-06-01

    We prove that the energy gap of the model proposed by Zhang et al (2016 arXiv:1606.07795) is exponentially small in the square of the system size. In Movassagh and Shor (2016 Proc. Natl Acad. Sci. USA) a class of exactly solvable quantum spin chain models was proposed that have integer spins (s), with a nearest neighbors Hamiltonian, and a unique ground state. The ground state can be seen as a uniform superposition of all s-colored Motzkin walks. The half-chain entanglement entropy provably violates the area law by a square root factor in the system’s size (˜\\sqrt{n} ) for s  >  1. For s  =  1, the violation is logarithmic (Bravyi et al 2012 Phys. Rev. Lett. 109 207202). Moreover in Movassagh and Shor (2016 Proc. Natl Acad. Sci. USA) it was proved that the gap vanishes polynomially and is O(n -c ) with c≥slant2 . Recently, a deformation of Movassagh and Shor (2016 Proc. Natl Acad. Sci. USA), which we call ‘weighted Motzkin quantum spin chain’ was proposed Zhang et al (2016 arXiv:1606.07795). This model has a unique ground state that is a superposition of the s-colored Motzkin walks weighted by tarea\\{Motzkin walk\\} with t  >  1. The most surprising feature of this model is that it violates the area law by a factor of n. Here we prove that the gap of this model is upper bounded by 8ns t-n2/3 for t  >  1 and s  >  1.

  6. Differentiation between cavernous hemangiomas and untreated malignant neoplasms of the liver with free-breathing diffusion-weighted MR imaging: Comparison with T2-weighted fast spin-echo MR imaging

    International Nuclear Information System (INIS)

    Soyer, Philippe; Corno, Lucie; Boudiaf, Mourad; Aout, Mounir; Sirol, Marc; Place, Vinciane; Duchat, Florent; Guerrache, Youcef; Fargeaudou, Yann; Vicaut, Eric; Pocard, Marc; Hamzi, Lounis

    2011-01-01

    Objective: To test interobserver variability of ADC measurements and compare the diagnostic performances of free-breathing diffusion-weighted (FBDW) with that of T2-weighted FSE (T2WFSE) MR imaging for differentiating between cavernous hemangiomas and untreated malignant hepatic neoplasms. Materials and methods: Thirty-five patients with cavernous hemangiomas and 35 with untreated hepatic malignant neoplasms had FBDW and T2WFSE MR imaging. Hepatic lesions were characterized with ADC measurement and visual evaluation. Interobserver agreement for ADC measurement was calculated. Association between ADC value and lesion type was assessed using univariate analysis. Sensitivity, specificity and accuracy of ADC values and visual evaluation of MR images for the diagnosis of untreated malignant hepatic neoplasm were compared. Results: ADC measurements showed excellent interobserver correlation (intraclass correlation coefficient = 0.980). Malignant neoplasms had lower ADC values than hemangiomas for the two observers (1.11 x 10 -3 mm 2 /s ± .21 x 10 -3 vs. 1.77 x 10 -3 mm 2 /s ± .29 x 10 -3 for observer 1 and 1.11 x 10 -3 mm 2 /s ± .19 x 10 -3 vs. 1.79 x 10 -3 mm 2 /s ± .32 x 10 -3 for observer 2) and univariate analysis found significant correlations between lesion type and ADC values. Depending on ADC threshold value, accuracy for the diagnosis of malignant neoplasm varied from 82.9% to 94.3%. Using visual evaluation, FBDW showed better specificity and accuracy than T2WFSE MR images for the diagnosis of malignant neoplasm (97.1% vs. 77.1% and 94.3% vs. 62.9%, respectively). Conclusion: FBDW imaging provides reproducible quantitative information and surpasses the value of T2WFSE MR imaging for differentiating between cavernous hemangiomas and untreated malignant hepatic neoplasms.

  7. T2-weighted MRI-derived textural features reflect prostate cancer aggressiveness: preliminary results

    NARCIS (Netherlands)

    Nketiah, G.; Elschot, M.; Kim, E.; Teruel, J.R.; Scheenen, T.W.J.; Bathen, T.F.; Selnaes, K.M.

    2017-01-01

    PURPOSE: To evaluate the diagnostic relevance of T2-weighted (T2W) MRI-derived textural features relative to quantitative physiological parameters derived from diffusion-weighted (DW) and dynamic contrast-enhanced (DCE) MRI in Gleason score (GS) 3+4 and 4+3 prostate cancers. MATERIALS AND METHODS:

  8. Impact of high field (3.0 T) magnetic resonance imaging on diagnosis of osteochondral defects in the ankle joint

    International Nuclear Information System (INIS)

    Schibany, N.; Ba-Ssalamah, A.; Marlovits, S.; Mlynarik, V.; Noebauer-Huhmann, I.M.; Striessnig, G.; Shodjai-Baghini, M.; Heinze, G.; Trattnig, S.

    2005-01-01

    Objective: To evaluate high field magnetic resonance (MR) imaging for imaging of osteochondral defects. Materials and methods: Nine osteochondral defects were simulated in three cadaveric talus specimens using a diamond drill. All specimens were examined on a 1.0 T MR unit and a 3.0 T MR unit. A T2-weighted turbo spin-echo (TSE) sequence with a 2 mm slice thickness and a 256 x 256 matrix size was used on both scanners. The visibility of the osteochondral separation and the presence of susceptibility artifacts at the drilling bores were scored on all images. Results: Compared to the 1.0 T MR unit, the protocol on the 3.0 T MR unit allowed a better delineation of the disruption of the articular cartilage and a better demarcation of the subchondral defect. Differences regarding the visualization of the subchondral defect were found to be statistically significant (P 0.05). The average SNR was higher using 3.0 T MRI (SNR = 12), compared to 1.0 T MRI (SNR = 7). Conclusion: High field MRI enables the acquisition of images with sufficient resolution and higher SNR and has therefore the potential to improve the staging of osteochondral defects

  9. Diffusion-weighted and T2-weighted MR imaging for colorectal liver metastases detection in a rat model at 7 T: a comparative study using histological examination as reference

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Mathilde; Ronot, Maxime; Vilgrain, Valerie; Beers, Bernard E. van [University Paris Diderot, Sorbonne Paris Cite, INSERM UMR 773, University Hospitals Paris Nord Val de Seine, Beaujon, Assistance Publique- Hopitaux de Paris, Laboratory of Physiological and Molecular Imaging of the Abdomen (IPMA) and Department of Radiology, Clichy Cedex (France); Maggiori, Leon; Panis, Yves [University Paris Diderot, Sorbonne Paris Cite, INSERM UMR 773, University Hospitals Paris Nord Val de Seine, Beaujon, Assistance Publique-Hopitaux de Paris, Department of Colorectal Surgery, Clichy (France); Paradis, Valerie [University Paris Diderot, Sorbonne Paris Cite, INSERM UMR 773, University Hospitals Paris Nord Val de Seine, Beaujon, Assistance Publique-Hopitaux de Paris, Department of Pathology, Clichy (France)

    2013-08-15

    To compare diffusion-weighted (DW) and T2-weighted MR imaging in detecting colorectal liver metastases in a rat model, using histological examination as a reference method. Eighteen rats had four liver injections of colon cancer cells. MR examinations at 7 T included FSE-T2-weighted imaging and SE-DW MR imaging (b = 0, 20 and 150 s/mm{sup 2}) and were analysed by two independent readers. Histological examination was performed on 0.4-mm slices. McNemar's test was used to compare the sensitivities and the Wilcoxon matched pairs test to compare the average number of false-positives per rat. One hundred and sixty-six liver metastases were identified on histological examination. The sensitivity in detecting liver metastases was significantly higher on DW MR than on T2-weighted images (99/166 (60 %) (reader 1) and 92/166 (55 %) (reader 2) versus 77/166 (46 %), P {<=} 0.001), without an increase in false-positives per rat (P = 0.773/P = 0.850). After stratification according to metastasis diameter, DW MR imaging had a significantly higher sensitivity than T2-weighted imaging only for metastases with a diameter (0.6-1.2 mm) similar to that of the spatial resolution of MR imaging in the current study. This MR study with histological correlations shows the higher sensitivity of DW relative to T2-weighted imaging at 7 T for detecting liver metastases, especially small ones. (orig.)

  10. High incidence of microbleeds in hemodialysis patients detected by T2*-weighted gradient-echo magnetic resonance imaging

    International Nuclear Information System (INIS)

    Yokoyama, Shunichi; Uomizu, Kenji; Kajiya, Yoriko; Tajitsu, Kenichiro; Kusumoto, Kazuhiro; Hirano, Hirofumi

    2005-01-01

    The incidence and characteristics of microbleeds in hemodialysis (HD) patients were investigated to elucidate the clinical significance with T 2 * -weighted gradient-echo magnetic resonance (MR) imaging. The 57 patients with chronic renal failure maintained by HD had no previous history of stroke. The control group consisted of 53 patients without previous history of stroke or chronic renal failure. The incidence and the number of microbleeds were assessed in the HD and control groups. The findings of microbleeds with T 2 * -weighted gradient-echo MR imaging were compared with those of T 1 - and T 2 -weighted MR imaging in HD patients. The incidence of microbleeds was significantly greater in the HD patients compared with the control patients. T 2 * -weighted gradient-echo imaging revealed a total of 44 microbleeds in 11 HD patients. T 2 -weighted imaging demonstrated 13 of 44 microbleeds as hyperintensity, whereas T 1 -weighted imaging demonstrated 12 lesions as hypointensity. T 2 - and T 1 -weighted imagings did not demonstrate any findings in 31 and 32 lesions, respectively. T 2 * -weighted gradient-echo MR imaging is effective to detect microbleeds which may be a predictor of intracerebral hemorrhage in HD patients and should be included in the protocol for the study of cerebrovascular disease, because T 2 - and T 1 -weighted MR imaging recognizes microbleeds as lacunar infarction. (author)

  11. T1-weighted vs. short-TE-long-TR images. Usefulness for knee MR examinations of ligament and meniscal lesions

    International Nuclear Information System (INIS)

    Endo, Hideho; Wada, Mitsuyoshi; Shiotani, Seiji; Niitsu, Mamoru; Itai, Yuji

    2000-01-01

    The purpose of this study was to compare short-TE-long-TR images with T1-weighed images in knee MR examinations. Sagittal MR images of the knee were obtained in 31 patients with knee pain. T1-weighted images were obtained by the spin-echo technique (TR/TE =350/15), and short-TE-long-TR images by fast spin-echo (TR/TE =1300/15) with an echo-train length of 5. Contrast-to-noise-ratios (CNRs) of the anterior cruciate ligament and synovial space, meniscus and articular cartilage, and meniscal lesion and normal meniscus were compared between short-TE-long-TR images and T1-weighted images. On each of the three examinations, short-TE-long-TR images provided significantly higher CNRs than T1-weighted images. It was concluded that short-TE-long-TR images can be a useful alternative to T1-weighted images in evaluating the anterior cruciate ligament and meniscal lesions. (author)

  12. T1-weighted vs. short-TE-long-TR images. Usefulness for knee MR examinations of ligament and meniscal lesions

    Energy Technology Data Exchange (ETDEWEB)

    Endo, Hideho; Wada, Mitsuyoshi; Shiotani, Seiji [Tsukuba Medical Center Hospital, Ibaraki (Japan); Niitsu, Mamoru; Itai, Yuji

    2000-11-01

    The purpose of this study was to compare short-TE-long-TR images with T1-weighed images in knee MR examinations. Sagittal MR images of the knee were obtained in 31 patients with knee pain. T1-weighted images were obtained by the spin-echo technique (TR/TE =350/15), and short-TE-long-TR images by fast spin-echo (TR/TE =1300/15) with an echo-train length of 5. Contrast-to-noise-ratios (CNRs) of the anterior cruciate ligament and synovial space, meniscus and articular cartilage, and meniscal lesion and normal meniscus were compared between short-TE-long-TR images and T1-weighted images. On each of the three examinations, short-TE-long-TR images provided significantly higher CNRs than T1-weighted images. It was concluded that short-TE-long-TR images can be a useful alternative to T1-weighted images in evaluating the anterior cruciate ligament and meniscal lesions. (author)

  13. Gelfand-Dickey algebra and higher spin symmetries on T2

    International Nuclear Information System (INIS)

    Sedra, M.B.

    2007-08-01

    We focus in this work to renew the interest in higher conformal spins symmetries and their relations to quantum field theories and integrable models. We consider the extension of the conformal Frappat et al. symmetries containing the Virasoro and the Antoniadis et al. algebras as particular cases describing geometrically special diffeomorphisms of the two dimensional torus T 2 . We show in a consistent way, and explicitly, how one can extract these generalized symmetries from the Gelfand-Dickey algebra. The link with Liouville and Toda conformal field theories is established and various important properties are discussed. (author)

  14. First Measurements of Spin Correlation Using Semi-leptonic $t\\bar{t}$ Events at ATLAS

    CERN Document Server

    Lemmer, Boris; The ATLAS collaboration

    2014-01-01

    The top quark decays before it hadronizes. Before its spin state can be changed in a process of strong interaction, it is directly transferred to the top quark decay products. The top quark spin can be deduced by studying angular distributions of the decay products. The Standard Model predicts the top/anti-top quark ($t\\bar{t}$) pairs to have correlated spins. The degree is sensitive to the spin and the production mechanisms of the top quark. Measuring the spin correlation allows to test the predictions. New physics effects can be reflected in deviations from the prediction. The measurement of the spin correlation of $t\\bar{t}$ pairs, produced at the LHC with a center-of-mass energy of $\\sqrt{s} = 7$ TeV and reconstructed with the ATLAS detector, is presented. The dataset corresponds to an integrated luminosity of 4.6 $\\textrm{fb}^{-1}$. $t\\bar{t}$ pairs are reconstructed in the $\\ell$+jets channel using a kinematic likelihood fit offering the identification of light up- and down-type quarks from the $t \\righ...

  15. What is the best MR sepuence to evaluate normal structures of kidney?

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Hwan Hoon; Seol, Young Hae; Park, Chul Min; Kim, Jung Hyuk; Kim, Yun Hwan; Lee, Nam Jun; Chung, Kyoo Byung; Suh, Won Hyuk [Korea Univ. College of Medicine, Seoul (Korea, Republic of)

    2001-01-01

    To determine the best MR sequence for evaluation of the anatomical structures of normal kidney. Twenty normal volunteers (M:F = 15:5) took part in this study, and for each, seven sequences were performed. The T1 weighed sequences were conventional spin echo T1 (Conv-SET1), turbo spin echo T1 (TSET1), and fast low angle shot (FLASH), while the T2 weighted sequences were turbo spin echo T2 (TSET2), half-Fourier acquisition single -shot turbo spin echo (HASTE), true-fast imaging with steadystate precession (True-FISP), and echoplanar imaging (EPI). The study involved quantitative and puantitative analysis. In quantitative analysis, CNRs between cortex and adjacent fat tissue, and between cortex and medulla were calculated from SNR (signal to noise ratio), and the CNRs of sequences were statistcally compared. In quantative analysis, three radiologists collectively evaluated kidney outline, cortico-medullary division, the renal vessels, the pelvis/ureter, and artifacts. For each sequence a grade was assigned, and for each parameter the grades were compared. Between cortex and adjacent fat, the highest CNR was shown by TSET1, followed by Conv-SET1, while among T2 sequences, the CNR shown by TSET2 was highest. Between cortex and medulla, the CNR demonstarted by the three T1 sequences showed no statistically significant differance. Among T2 sequences, however, HASTE showed the highest CNR, followed by EPI, and sttistcally, the findings for these two were significantly differnt from those of other T2 sepuences. Among T1 sequences, FLASH provided the best kidney outline, though among T2-sequences there was no statiscally significant difference. FLASH was also the best for cortico-medullary distinstion, while for tis purpose the best T2 sequence was HASTE. True -FISP was best for the evaluation of renal vessels, and HASTE for evaulating the pelvis and ureter. Artifacts were most prominent on Conv SET1. For evaluating the shape of the kidney, the best T2 sequence was TSET2

  16. What is the best MR sepuence to evaluate normal structures of kidney?

    International Nuclear Information System (INIS)

    Chung, Hwan Hoon; Seol, Young Hae; Park, Chul Min; Kim, Jung Hyuk; Kim, Yun Hwan; Lee, Nam Jun; Chung, Kyoo Byung; Suh, Won Hyuk

    2001-01-01

    To determine the best MR sequence for evaluation of the anatomical structures of normal kidney. Twenty normal volunteers (M:F = 15:5) took part in this study, and for each, seven sequences were performed. The T1 weighed sequences were conventional spin echo T1 (Conv-SET1), turbo spin echo T1 (TSET1), and fast low angle shot (FLASH), while the T2 weighted sequences were turbo spin echo T2 (TSET2), half-Fourier acquisition single -shot turbo spin echo (HASTE), true-fast imaging with steadystate precession (True-FISP), and echoplanar imaging (EPI). The study involved quantitative and puantitative analysis. In quantitative analysis, CNRs between cortex and adjacent fat tissue, and between cortex and medulla were calculated from SNR (signal to noise ratio), and the CNRs of sequences were statistcally compared. In quantative analysis, three radiologists collectively evaluated kidney outline, cortico-medullary division, the renal vessels, the pelvis/ureter, and artifacts. For each sequence a grade was assigned, and for each parameter the grades were compared. Between cortex and adjacent fat, the highest CNR was shown by TSET1, followed by Conv-SET1, while among T2 sequences, the CNR shown by TSET2 was highest. Between cortex and medulla, the CNR demonstarted by the three T1 sequences showed no statistically significant differance. Among T2 sequences, however, HASTE showed the highest CNR, followed by EPI, and sttistcally, the findings for these two were significantly differnt from those of other T2 sepuences. Among T1 sequences, FLASH provided the best kidney outline, though among T2-sequences there was no statiscally significant difference. FLASH was also the best for cortico-medullary distinstion, while for tis purpose the best T2 sequence was HASTE. True -FISP was best for the evaluation of renal vessels, and HASTE for evaulating the pelvis and ureter. Artifacts were most prominent on Conv SET1. For evaluating the shape of the kidney, the best T2 sequence was TSET2

  17. Canonical Drude Weight for Non-integrable Quantum Spin Chains

    Science.gov (United States)

    Mastropietro, Vieri; Porta, Marcello

    2018-03-01

    The Drude weight is a central quantity for the transport properties of quantum spin chains. The canonical definition of Drude weight is directly related to Kubo formula of conductivity. However, the difficulty in the evaluation of such expression has led to several alternative formulations, accessible to different methods. In particular, the Euclidean, or imaginary-time, Drude weight can be studied via rigorous renormalization group. As a result, in the past years several universality results have been proven for such quantity at zero temperature; remarkably, the proofs work for both integrable and non-integrable quantum spin chains. Here we establish the equivalence of Euclidean and canonical Drude weights at zero temperature. Our proof is based on rigorous renormalization group methods, Ward identities, and complex analytic ideas.

  18. T1-weighted fluid-attenuated inversion recovery and T1-weighted fast spin-echo contrast-enhanced imaging: a comparison in 20 patients with brain lesions

    International Nuclear Information System (INIS)

    Al-Saeed, O.; Athyal, R. P.; Ismail, M.; Rudwan, M.; Khafajee, S.

    2009-01-01

    Full text: Tl-weighted fluid-attenuated inversion recovery (FLAIR) sequence is a relatively new pulse sequence for intracranial MR imaging. This study was performed to compare the image quality of Tl-weighted FLAIR with the Tl-weighted FSE sequence. Twenty patients with brain lesions underwent Tl-weighted fast spin-echo (FSE) and Tl-weighted FLAIR during the same imaging session. Four quantitative and three qualitative criteria were used to compare the two sequences after contrast. Two of four quantitative criteria pertained to lesion characteristics: lesion to white matter (WM) contrast-to-noise ratio (CNR) and lesion to cerebrospinal fluid (CSF) CNR, and two related to signals from normal tissue: grey matter to WM CNR and WM to CSF CNR. The three qualitative criteria were conspicuousness of the lesion, the presence of image artefacts and the overall image contrast. Both Tl-weighted FSE and FLAIR images were effective in demonstrating lesions. Image contrast was superior in Tl-weighted FLAIR images with significantly improved grey matter-WM CNRs and CSF-WM CNRs. The overall image contrast was judged to be superior on Tl-weighted FLAIR images compared with Tl-weighted FSE images by all neuroradiologists. Two of three reviewers considered that the FLAIR images had slightly increased imaging artefacts that, however, did not interfere with image interpretation. Tl-weighted FLAIR imaging provides improved lesion-to-background and grey to WM contrast-to-noise ratios. Superior conspicuity of lesions and overall image contrast is obtained in comparable acquisition times. These indicate an important role for Tl-weighted FLAIR in intracranial imaging and highlight its advantage over the more widely practiced Tl-weighted FSE sequence

  19. Helium turbo-expander with an alternator

    International Nuclear Information System (INIS)

    Akiyama, Yoshitane

    1980-01-01

    Study was made on a helium turbo-expander, the heart of helium refrigerator systems, in order to develop a system which satisfies the required conditions. A helium turbo-expander with externally pressurized helium gas bearings at the temperature of liquid nitrogen and an alternator as a brake have been employed. The essential difference between a helium turbo-expander and a nitrogen turbo-expander was clarified. The gas bearing lubricated with nitrogen at room temperature and the gas bearing lubricated with helium at low temperature were tested. The flow rate of helium in a helium refrigerator for a large superconducting magnet is comparatively small, therefore a helium turbine must be small, but the standard for large turbine design can be applied to such small turbine. Using the alternator as a brake, the turbo-expander was easily controllable electrically. The prototype turbo-expander was made, and the liquefaction test with it and MHD power generation test were carried out. (Kako, I.)

  20. Can T1 w/T2 w ratio be used as a myelin-specific measure in subcortical structures? Comparisons between FSE-based T1 w/T2 w ratios, GRASE-based T1 w/T2 w ratios and multi-echo GRASE-based myelin water fractions.

    Science.gov (United States)

    Uddin, Md Nasir; Figley, Teresa D; Marrie, Ruth Ann; Figley, Chase R

    2018-03-01

    Given the growing popularity of T 1 -weighted/T 2 -weighted (T 1 w/T 2 w) ratio measurements, the objective of the current study was to evaluate the concordance between T 1 w/T 2 w ratios obtained using conventional fast spin echo (FSE) versus combined gradient and spin echo (GRASE) sequences for T 2 w image acquisition, and to compare the resulting T 1 w/T 2 w ratios with histologically validated myelin water fraction (MWF) measurements in several subcortical brain structures. In order to compare these measurements across a relatively wide range of myelin concentrations, whole-brain T 1 w magnetization prepared rapid acquisition gradient echo (MPRAGE), T 2 w FSE and three-dimensional multi-echo GRASE data were acquired from 10 participants with multiple sclerosis at 3 T. Then, after high-dimensional, non-linear warping, region of interest (ROI) analyses were performed to compare T 1 w/T 2 w ratios and MWF estimates (across participants and brain regions) in 11 bilateral white matter (WM) and four bilateral subcortical grey matter (SGM) structures extracted from the JHU_MNI_SS 'Eve' atlas. Although the GRASE sequence systematically underestimated T 1 w/T 2 w values compared to the FSE sequence (revealed by Bland-Altman and mountain plots), linear regressions across participants and ROIs revealed consistently high correlations between the two methods (r 2 = 0.62 for all ROIs, r 2 = 0.62 for WM structures and r 2 = 0.73 for SGM structures). However, correlations between either FSE-based or GRASE-based T 1 w/T 2 w ratios and MWFs were extremely low in WM structures (FSE-based, r 2 = 0.000020; GRASE-based, r 2 = 0.0014), low across all ROIs (FSE-based, r 2 = 0.053; GRASE-based, r 2 = 0.029) and moderate in SGM structures (FSE-based, r 2 = 0.20; GRASE-based, r 2 = 0.17). Overall, our findings indicated a high degree of correlation (but not equivalence) between FSE-based and GRASE-based T 1 w/T 2 w ratios, and low correlations between T 1 w/T 2 w ratios and MWFs. This

  1. Imaging of the brain using the fast-spin-echo and gradient-spin-echo techniques

    International Nuclear Information System (INIS)

    Umek, W.; Ba-Ssalamah, A.; Prokesch, R.; Mallek, R.; Heimberger, K.; Hittmair, K.

    1998-01-01

    The aim of our study was to compare gradient-spin-echo (GRASE) to fast-spin-echo (FSE) sequences for fast T2-weighted MR imaging of the brain. Thirty-one patients with high-signal-intensity lesions on T2-weighted images were examined on a 1.5-T MR system. The FSE and GRASE sequences with identical sequence parameters were obtained and compared side by side. Image assessment criteria included lesion conspicuity, contrast between different types of normal tissue, and image artifacts. In addition, signal-to-noise, contrast-to-noise, and contrast ratios and were determined. The FSE technique demonstrated more lesions than GRASE and with generally better conspicuity. Smaller lesions in particular were better demonstrated on FSE because of lower image noise and slightly weaker image artifacts. Gray-white differentiation was better on FSE. Ferritin and hemosiderin depositions appeared darker on GRASE, which resulted in better contrast. Fatty tissue was less bright on GRASE. With current standard hardware equipment, the FSE technique seems preferable to GRASE for fast T2-weighted routine MR imaging of the brain. For the assessment of hemosiderin or ferritin depositions, GRASE might be considered. (orig.)

  2. MR colonography with fecal tagging: comparison between 2D turbo FLASH and 3D FLASH sequences

    International Nuclear Information System (INIS)

    Papanikolaou, Nickolas; Grammatikakis, John; Maris, Thomas; Prassopoulos, Panos; Gourtsoyiannis, Nicholas; Lauenstein, Thomas

    2003-01-01

    The objective of this study was to compare inversion recovery turbo 2D fast low-angle shot (FLASH) and 3D FLASH sequences for fecal-tagged MR colonography studies. Fifteen consecutive patients with indications for colonoscopy underwent MR colonography with fecal tagging. An inversion recovery turbo-FLASH sequence was applied and compared in terms of artifacts presence, efficiency for masking residual stool, and colonic wall conspicuity with a fat-saturated 3D FLASH sequence. Both sequences were acquired following administration of paramagnetic contrast agent. Contrast-to-noise ratio and relative contrast between colonic wall and lumen were calculated and compared for both sequences. Turbo 2D FLASH provided fewer artifacts, higher efficiency for masking the residual stool, and colonic wall conspicuity equivalent to 3D FLASH. An inversion time of 10 ms provided homogeneously low signal intensity of the colonic lumen. Contrast to noise between colonic wall and lumen was significantly higher in the 3D FLASH images, whereas differences in relative contrast were not statistically significant. An optimized inversion-recovery 2D turbo-FLASH sequence provides better fecal tagging results and should be added to the 3D FLASH sequence when designing dark-lumen MR colonography examination protocols. (orig.)

  3. Physiological Background of Differences in Quantitative Diffusion-Weighted Magnetic Resonance Imaging Between Acute Malignant and Benign Vertebral Body Fractures: Correlation of Apparent Diffusion Coefficient With Quantitative Perfusion Magnetic Resonance Imaging Using the 2-Compartment Exchange Model.

    Science.gov (United States)

    Geith, Tobias; Biffar, Andreas; Schmidt, Gerwin; Sourbron, Steven; Dietrich, Olaf; Reiser, Maximilian; Baur-Melnyk, Andrea

    2015-01-01

    To test the hypothesis that apparent diffusion coefficient (ADC) in vertebral bone marrow of benign and malignant fractures is related to the volume of the interstitial space, determined with dynamic contrast-enhanced (DCE) magnetic resonance imaging. Patients with acute benign (n = 24) and malignant (n = 19) vertebral body fractures were examined at 1.5 T. A diffusion-weighted single-shot turbo-spin-echo sequence (b = 100 to 600 s/mm) and DCE turbo-FLASH sequence were evaluated. Regions of interest were manually selected for each fracture. Apparent diffusion coefficient was determined with a monoexponential decay model. The DCE magnetic resonance imaging concentration-time curves were analyzed using a 2-compartment tracer-kinetic model. Apparent diffusion coefficient showed a significant positive correlation with interstitial volume in the whole study population (Pearson r = 0.66, P correlation between ADC and the permeability-surface area product could be observed when analyzing the whole study population (Spearman rs = 0.40, P = 0.008), but not when separately examining the subgroups. Plasma flow showed a significant correlation with ADC in benign fractures (Pearson r = 0.23, P = 0.03). Plasma volume did not show significant correlations with ADC. The results support the hypothesis that the ADC of a lesion is inversely correlated to its cellularity. This explains previous observations that ADC is reduced in more malignant lesions.

  4. Variable-flip-angle spin-echo imaging (VFSE)

    International Nuclear Information System (INIS)

    Kasai, Toshifumi; Sugimura, Kazuro; Kawamitsu, Hideaki; Yasui, Kiyoshi; Ishida, Tetsuya; Tsukamoto, Tetsuji.

    1990-01-01

    T 2 weighted imaging provides images with high object contrast for pathologic conditions in which the water content of tissues is increased. The authors predicted theoretical analysis of the effects of changing flip angle, and analyzed the effects in MR imaging of both phantoms and humans. Variable flip angle spin echo MR imaging (VFSE) with a 1,000/80 (repetition time msec/echo time msec) can obtain T 2 weighted image when flip angle is smaller than 80 degrees. VFSE with 40 to 60 degrees flip angle have higher contrast than other flip angle images. Signal to noise ratio (S/N) of VFSE are 55% at a 30 degree, 76% at a 45 degree, 92% at a 60 degree respectively as compared with conventional spin echo image (2000/80, flip angle 90 degree). VFSE is applicable to obtain T 2 weighted image reduced imaging time. (author)

  5. Postero-anterior radiogram of the knee in weight-bearing and semiflexion. Comparison with MR imaging

    International Nuclear Information System (INIS)

    Boegaard, T.; Rudling, O.; Sanfridsson, J.; Jonsson, K.; Saxne, T.; Svensson, B.

    1997-01-01

    Purpose: The purpose was four-fold: to assess the reproducibility of p.a. weight-bearing radiograms of the knee and the minimal joint-space (MJS) width measurements in these radiograms; to compare the MJS with MR-detected cartilage defects; to evaluate the location of these cartilage defects; and to estimate the relation between meniscal abnormalities and joint-space narrowing. Material and Methods: Fifty-nine individuals, aged 41-58 years (mean 50), with chronic knee pain were examined by means of p.a. weight-bearing radiograms in semiflexion with fluoroscopic guidance of the knee joint. The MJS was measured with a standard ruler. On the same day MR imaging was performed with proton-density- and T2-weighted turbo spin-echo on a 1.0 T imager. Meniscal abnormalities and cartilage defects in the tibiofemoral joint (TFJ) were noted. Results and Conclusion: The p.a. view of the knee and the MJS measurements were reproducible. MJS of 3 mm is a limit in diagnosing joint-space narrowing in knees with MR-detected cartilage defects. There was a high proportion (p<0.001) of meniscal abnormality within the narrowed compartments in comparison with those that were not narrowed. A larger number of the cartilage defects (p<0.05) was found in the medial femoral condyle than in any of the other condyles of the TFJ. The defects had a dorsal location (p<0.001) as shown in the weight-bearing radiograms of the knee in semiflexion. (orig.)

  6. Signs of patellar chondromalacia on sagittal T2-weighted magnetic resonance imaging

    International Nuclear Information System (INIS)

    De Smet, A.A.; Monu, J.U.; Fisher, D.R.; Keene, J.S.; Graf, B.K.

    1992-01-01

    We incidentally noted distinctive high signal defects or fissures in the patellar articular cartilage on sagittal T2-weighted magnetic resonance (MR) images in 4 patients. At subsequent arthroscopy all 4 patients were found to have patellar chondromalacia. To determine the reliabilty of these signs, we retrospectively evaluated, in a blinded manner, sagittal T2-weighted MR images of the knee in 75 patients who were undergoing arthroscopic assessment of their patellar articular cartilage. We indentified high signal defects of fissures in the patellar cartilage of 5 patients. Patellar chondromalacia was noted at arthroscopy in all 5 patients. Arthroscopy demonstrated patellar chondromalacia in an additional 21 patients with normal MR images. We conclude that high signal defects or fissures on sagittal T2-weighted images are usefull signs of patellar chondromalacia. This single imaging sequence will, however, detect only a small number of the cartilage lesions that may be present. (orig.)

  7. Signs of patellar chondromalacia on sagittal T2-weighted magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    De Smet, A.A.; Monu, J.U.; Fisher, D.R. (Univ. of Wisconsin Hospital and Clinics, Dept. of Radiology, Madison, WI (United States)); Keene, J.S.; Graf, B.K. (Univ. of Wisconsin Hospital and Clinics, Div. of Orthopedic Surgery, Madison, WI (United States))

    1992-02-01

    We incidentally noted distinctive high signal defects or fissures in the patellar articular cartilage on sagittal T2-weighted magnetic resonance (MR) images in 4 patients. At subsequent arthroscopy all 4 patients were found to have patellar chondromalacia. To determine the reliabilty of these signs, we retrospectively evaluated, in a blinded manner, sagittal T2-weighted MR images of the knee in 75 patients who were undergoing arthroscopic assessment of their patellar articular cartilage. We indentified high signal defects of fissures in the patellar cartilage of 5 patients. Patellar chondromalacia was noted at arthroscopy in all 5 patients. Arthroscopy demonstrated patellar chondromalacia in an additional 21 patients with normal MR images. We conclude that high signal defects or fissures on sagittal T2-weighted images are usefull signs of patellar chondromalacia. This single imaging sequence will, however, detect only a small number of the cartilage lesions that may be present. (orig.).

  8. Detection of prostate carcinomas with T1-weighted dynamic contrast-enhanced MRI. Value of two-compartment model; Detektion von Prostatakarzinomen mit T1-gewichteter Kontrastmittel-unterstuetzter dynamischer MRT. Wertigkeit des Zweikompartimentemodells

    Energy Technology Data Exchange (ETDEWEB)

    Kiessling, F.; Lichy, M.; Farhan, N.; Delorme, S.; Kauczor, H.U. [Abteilung fuer Radiologie, Deutsches Krebsforschungszentrum (DKFZ) Heidelberg (Germany); Grobholz, R. [Abteilung fuer Pathologie, Universitaetsklinikum Mannheim (Germany); Heilmann, M. [Abteilung fuer Physik in der Radiologie, Deutsches Krebsforschungszentrum (DKFZ) Heidelberg (Germany); Michel, M.S.; Trojan, L. [Abteilung fuer Urologie, Universitaetsklinikum Mannheim (Germany); Werner, A.; Rabe, J. [Institut fuer Klinische Radiologie, Universitaetsklinikum Mannheim (Germany); Schlemmer, H.P. [Abteilung fuer Diagnostische Radiologie, Universitaetsklinikum Tuebingen (Germany)

    2003-06-01

    Aim The suitability of dynamic parameters of the two-compartment model for detecting prostate carcinomas and its correlation with tumor microvascular density were evaluated. The study included 43 patients with biopsy-proven prostate carcinoma: 28 were examined by 1.0-T MRI (Turbo-FLASH) and 15 by 1.5-T MRI (FLASH) with infusion of 0.1 mmol/kg Gd-DTPA. Signal time curves were parametrized with an open two-compartment model in amplitude and exchange rate constants (k{sub ep}).The microvascular density of resected prostate carcinomas was determined. The microvascular density in the tumors was significantly higher than in the adjacent healthy prostate tissue and correlated in both sequences with k{sub ep}. Prostate carcinomas of the peripheral zone were demarcated by amplitude and k{sub ep}. In the Turbo-FLASH sequence there was a significant difference between the tumor tissue and healthy peripheral zone in terms of k{sub ep} and in the FLASH sequence in terms of amplitude. Prostate carcinomas can be visualized with dynamic T1-weighted MR sequences using a two-compartment model. Moreover, the parameter k{sub ep} reveals the microvascular density in the tumor and can thus provide valuable clinical information for characterizing the tumors. (orig.) [German] Die Eignung dynamischer Parameter des Zweikompartimentemodells zur Erkennung von Prostatakarzinomen und deren Korrelation mit der Tumormikrogefaessdichte wurden evaluiert. 43 Patienten mit bioptisch gesichertem Prostatakarzinom wurden untersucht, 28 mit 1,0 T- (Turbo-FLASH-) und 15 bei 1,5-T-MRT (FLASH) unter Infusion von 0,1 mmol/kg Gd-DTPA. Signal-Zeit-Kurven wurden nach einem offenen Zweikompartimentemodell in Amplitude sowie Austauschratenkonstante (k{sub ep}) parametrisiert. An resezierten Prostatakarzinomen wurde die Mikrogefaessdichte bestimmt.Ergebnisse Die Mikrogefaessdichte in den Tumoren war signifikant hoeher als im angrenzenden gesunden Prostatagewebe und korrelierte bei beiden Sequenzen mit k{sub ep

  9. Microwave Amplitude Modulation Technique to Measure Spin-Lattice (T 1) and Spin-Spin (T 2) Relaxation Times

    Science.gov (United States)

    Misra, Sushil K.

    The measurement of very short spin-lattice, or longitudinal, relaxation (SLR) times (i.e., 10-10 Misra, 1998), and polymer resins doped with rare-earth ions (Pescia et al., 1999a; Pescia et al. 1999b). The ability to measure such fast SLR data on amorphous Si and copper-chromium-tin spinel led to an understanding of the role of exchange interaction in affecting spin-lattice relaxation, while the data on polymer resins doped with rare-earth ions provided evidence of spin-fracton relaxation (Pescia et al., 1999a, b). But such fast SLR times are not measurable by the most commonly used techniques of saturation- and inversion-recovery (Poole, 1982; Alger, 1968), which only measure spin-lattice relaxation times longer than 10-6 s. A summary of relevant experimental data is presented in Table 1.

  10. T2 black lesions on routine knee MRI: differential considerations

    International Nuclear Information System (INIS)

    Wadhwa, Vibhor; Cho, Gina; Moore, Daniel; Pezeshk, Parham; Coyner, Katherine; Chhabra, Avneesh

    2016-01-01

    The majority of abnormal findings or lesions on T2-weighted fast spin-echo (FSE) magnetic resonance imaging (MRI) are hyperintense due to increased perfusion or fluid content, such as infections, tumours or synovitis. Hypointense lesions on T2-weighted images (both fat-suppressed and non-fat-suppressed) are less common and can sometimes be overlooked. Such lesions have limited differential diagnostic possibilities, and include vacuum phenomenon, loose body, tenosynovial giant cell tumour, rheumatoid arthritis, haemochromatosis, gout, amyloid, chondrocalcinosis, hydroxyapetite deposition disease, lipoma arborescens, arthrofibrosis and iatrogenic lesions. These lesions often show characteristic appearances and predilections in the knee. In this article, the authors describe the MRI features of hypointense T2 lesions on routine knee MRI and outline a systematic diagnostic approach towards their evaluation. (orig.)

  11. A neurotological study of patients with pontine hyperintense lesions on T2 weighted MRI

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Toru; Tominaga, Satoru; Yukimasa, Akiko; Oku, Masaya; Sakagami, Masafumi [Hyogo Coll. of Medicine, Nishinomiya (Japan)

    2002-03-01

    Pontine hyperintense lesions seen on T2-weighted MRI were thought to be related to disequilibrium. Some of these lesions have a low signal on T1-weighted imaging, while others have an iso-signal. The purpose of this study was to clarify the relationship between neurological findings and pontine lesions detected by MRI. The subjects were 11 patients (6 males, 5 females; age range: 30 to 83 years [mean: 64.1 years]) with pontine hyperintense lesions identified on T2-weighted MRI. We compared the clinical signs and the MRI findings. Six of the patients had low-intensity areas on T1-weighted images, and the other 5 had iso-intensity areas. Six patients complained of vertigo, and 5 complained of dizziness. Eight complained of positionaly evoked disequilibrium. Positional nystagmus was seen in 4 patients. In 9 patients, abnormalities were found on the ENG test, including the saccadic eye movement test, ETT, and OKP. Numbness on the lips occurred in 2 patients, and cerebellar signs were present in 4. None of the patients had facial paralysis. Disequilibrium originating in the central nervous system was suggested in 10 patients. Clinical examinations revealed similar findings in patients with a low signal on T1-weighted MRI and those with an iso-signal. Our results indicate that pontine lesions identified by T2-weighted MRI cause vertigo or dizziness, and, in most cases, these lesions cause abnormal neurological or neurological abnormalities. (author)

  12. A neurotological study of patients with pontine hyperintense lesions on T2 weighted MRI

    International Nuclear Information System (INIS)

    Seo, Toru; Tominaga, Satoru; Yukimasa, Akiko; Oku, Masaya; Sakagami, Masafumi

    2002-01-01

    Pontine hyperintense lesions seen on T2-weighted MRI were thought to be related to disequilibrium. Some of these lesions have a low signal on T1-weighted imaging, while others have an iso-signal. The purpose of this study was to clarify the relationship between neurological findings and pontine lesions detected by MRI. The subjects were 11 patients (6 males, 5 females; age range: 30 to 83 years [mean: 64.1 years]) with pontine hyperintense lesions identified on T2-weighted MRI. We compared the clinical signs and the MRI findings. Six of the patients had low-intensity areas on T1-weighted images, and the other 5 had iso-intensity areas. Six patients complained of vertigo, and 5 complained of dizziness. Eight complained of positionaly evoked disequilibrium. Positional nystagmus was seen in 4 patients. In 9 patients, abnormalities were found on the ENG test, including the saccadic eye movement test, ETT, and OKP. Numbness on the lips occurred in 2 patients, and cerebellar signs were present in 4. None of the patients had facial paralysis. Disequilibrium originating in the central nervous system was suggested in 10 patients. Clinical examinations revealed similar findings in patients with a low signal on T1-weighted MRI and those with an iso-signal. Our results indicate that pontine lesions identified by T2-weighted MRI cause vertigo or dizziness, and, in most cases, these lesions cause abnormal neurological or neurological abnormalities. (author)

  13. A newly developed MR simulation system for intracavitary brachytherapy for cervical cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ebe, Kazuyu; Matsunaga, Naofumi [Yamaguchi Univ., Ube (Japan). School of Medicine

    1997-03-01

    We have developed a prototype system for a magnetic resonance (MR) simulation to accurately estimate radiation doses to the tumor and surrounding normal tissues during brachytherapy for cervical cancer. Six patients with cervical cancer underwent MR simulation prior to intracavitary high-dose-rate brachytherapy using Co-60 sources. Tandem and ovoid applicators filled with tap-water were placed in the uterine cavity and vaginal fornix, then MR imaging examinations were performed. Frontal and lateral images of maximum intensity projection (MIP) of applicators generated from a data set of half-Fourier single shot turbo spin-echo (HASTE) images were chosen for processing by the treatment planning computer system. Then, isodose curves on the coronal or sagittal plane of the tandem section were superimposed on corresponding T2-weighted images derived from a turbo spin-echo technique. Doses to the tumor, the posterior wall of the urinary bladder, the anterior wall of the rectum, and the urethra were read from isodose curves superimposed on the T2-weighted sagittal image. Phantom experiments were done to evaluate geometrical errors. The possible distortion of the lattice image on the phantom was small. This system promises to be useful in customizing the dose distribution corresponding to the tumor and surrounding normal tissues. (author)

  14. A newly developed MR simulation system for intracavitary brachytherapy for cervical cancer

    International Nuclear Information System (INIS)

    Ebe, Kazuyu; Matsunaga, Naofumi

    1997-01-01

    We have developed a prototype system for a magnetic resonance (MR) simulation to accurately estimate radiation doses to the tumor and surrounding normal tissues during brachytherapy for cervical cancer. Six patients with cervical cancer underwent MR simulation prior to intracavitary high-dose-rate brachytherapy using Co-60 sources. Tandem and ovoid applicators filled with tap-water were placed in the uterine cavity and vaginal fornix, then MR imaging examinations were performed. Frontal and lateral images of maximum intensity projection (MIP) of applicators generated from a data set of half-Fourier single shot turbo spin-echo (HASTE) images were chosen for processing by the treatment planning computer system. Then, isodose curves on the coronal or sagittal plane of the tandem section were superimposed on corresponding T2-weighted images derived from a turbo spin-echo technique. Doses to the tumor, the posterior wall of the urinary bladder, the anterior wall of the rectum, and the urethra were read from isodose curves superimposed on the T2-weighted sagittal image. Phantom experiments were done to evaluate geometrical errors. The possible distortion of the lattice image on the phantom was small. This system promises to be useful in customizing the dose distribution corresponding to the tumor and surrounding normal tissues. (author)

  15. High spatial resolution 3D MR cholangiography with high sampling efficiency technique (SPACE): Comparison of 3 T vs. 1.5 T

    Energy Technology Data Exchange (ETDEWEB)

    Arizono, Shigeki [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: arizono@kuhp.kyoto-u.ac.jp; Isoda, Hiroyoshi [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: sayuki@kuhp.kyoto-u.ac.jp; Maetani, Yoji S. [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: mbo@kuhp.kyoto-u.ac.jp; Hirokawa, Yuusuke [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: yuusuke@kuhp.kyoto-u.ac.jp; Shimada, Kotaro [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: kotaro@kuhp.kyoto-u.ac.jp; Nakamoto, Yuji [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: ynakamo1@kuhp.kyoto-u.ac.jp; Shibata, Toshiya [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: ksj@kuhp.kyoto-u.ac.jp; Togashi, Kaori [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: ktogashi@kuhp.kyoto-u.ac.jp

    2010-01-15

    Purpose: The aim of this study was to evaluate image quality of 3D MR cholangiography (MRC) using high sampling efficiency technique (SPACE) at 3 T compared with 1.5 T. Methods and materials: An IRB approved prospective study was performed with 17 healthy volunteers using both 3 and 1.5 T MR scanners. MRC images were obtained with free-breathing navigator-triggered 3D T2-weighted turbo spin-echo sequence with SPACE (TR, >2700 ms; TE, 780 ms at 3 T and 801 ms at 1.5 T; echo-train length, 121; voxel size, 1.1 mm x 1.0 mm x 0.84 mm). The common bile duct (CBD) to liver contrast-to-noise ratios (CNRs) were compared between 3 and 1.5 T. A five-point scale was used to compare overall image quality and visualization of the third branches of bile duct (B2, B6, and B8). The depiction of cystic duct insertion and the highest order of bile duct visible were also compared. The results were compared using the Wilcoxon signed-ranks test. Results: CNR between the CBD and liver was significantly higher at 3 T than 1.5 T (p = 0.0006). MRC at 3 T showed a significantly higher overall image quality (p = 0.0215) and clearer visualization of B2 (p = 0.0183) and B6 (p = 0.0106) than at 1.5 T. In all analyses of duct visibility, 3 T showed higher scores than 1.5 T. Conclusion: 3 T MRC using SPACE offered better image quality than 1.5 T. SPACE technique facilitated high-resolution 3D MRC with excellent image quality at 3 T.

  16. SU-E-J-224: Using UTE and T1 Weighted Spin Echo Pulse Sequences for MR-Only Treatment Planning; Phantom Study

    Energy Technology Data Exchange (ETDEWEB)

    Yu, H; Fatemi, A [Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada); Sahgal, A [University of Toronto, Toronto, ON (Canada)

    2015-06-15

    Purpose: Investigating a new approach in MRI based treatment planning using the combination of (Ultrashort Echo Time) UTE and T1 weighted spin echo pulse sequences to delineate air, bone and water (soft tissues) in generating pseudo CT images comparable with CT. Methods: A gel phantom containing chicken bones, ping pang balls filled with distilled water and air bubbles, was made. It scanned with MRI using UTE and 2D T1W SE pulse sequences with (in plane resolution= 0.53mm, slice thickness= 2 mm) and CT with (in plane resolution= 0.5 mm and slice thickness= 0.75mm) as a ground truth for geometrical accuracy. The UTE and T1W SE images were registered with CT using mutual information registration algorithm provided by Philips Pinnacle treatment planning system. The phantom boundaries were detected using Canny edge detection algorithm for CT, and MR images. The bone, air bubbles and water in ping pong balls were segmented from CT images using threshold 300HU, - 950HU and 0HU, respectively. These tissue inserts were automatically segmented from combined UTE and T1W SE images using edge detection and relative intensity histograms of the phantom. The obtained segmentations of air, bone and water inserts were evaluated with those obtained from CT. Results: Bone and air can be clearly differentiated in UTE images comparable to CT. Combining UTE and T1W SE images successfully segmented the air, bone and water. The maximum segmentation differences from combine MRI images (UTE and T1W SE) and CT are within 1.3 mm, 1.1mm for bone, air, respectively. The geometric distortion of UTE sequence is small less than 1 pixel (0.53 mm) of MR image resolution. Conclusion: Our approach indicates that MRI can be used solely for treatment planning and its quality is comparable with CT.

  17. MR imaging of intracerebral hemorrhage lesions: Comparison of 2.0 T and 0.5 T images

    International Nuclear Information System (INIS)

    Han, Moon Hee; Chang, Kee Hyun

    1990-01-01

    Seventeen patients with intracerebral hemorrhage lesions were examined with magnetic resonance imaging at both 2.0 T and 0.5 T, in order to evaluate the capability of detecting and characterizing the hemorrhagic lesions at each field strength and to compare the signal intensities of the hemorrhages between both field strengths. The intervals between two imagings were within 2 hours in all patients except for 4 patients with subacute hematoma and occult cerebrovascular malformations in whom the intervals were 1 to 4 days. At each field strength, both T1 and T2-weighted spin echo(SE) images were obtained in all patients. All the hemorrhagic lesions were readily detected and characterized as hemorrhagic lesions at 2.0 T, whereas one lesion of chronic hemorrhage was not detected, and three lesions(one acute hemorrhage, one chronic hemorrhage and one occult cerebrovascular malformation) could not be characterized as hemorrhagic lesions at 0.5 T. There were statistically significant differences in signal intensity of the hematomas between 2.0 T and 0.5 T on proton density-weighted and T2-weighted images in cases of acute intracerebral hematomas: the hematomas seen as low intensity at 2.0 T appeared iso-or slightly high at 0.5 T. In conclusion, the intracerebral hematomas may be difficult to detect and to characterize with SE technique at 0.5 T, and then the gradient echo technique may be useful at 0.5 T

  18. Turbo-machine deployment of HTR-10 GT

    International Nuclear Information System (INIS)

    Zhu Shutang; Wang Jie; Zhang Zhengming; Yu Suyuan

    2005-01-01

    As a testing project of gas turbine modular High Temperature Gas-cooled Reactor (HTGR), HTR-10GT has been studied and developed by Institute of Nuclear and New Energy Technology (INET) of Tsinghua University after the success of HTR-10 with steam turbine cycle. The main purposes of this project are to demonstrate the gas turbine modular HTGR, to optimize the deployment of Power Conversion Unit (PCU) and to verify the techniques of turbo-machine, operating modes and controlling measures. HTR-10GT is concentrated on the PCU design and the turbo-machine deployment. Possible turbo-machine deployments have been investigated and two of them are introduced in this paper. The preliminary design for the turbo-machine of HTR-10GT is single-shaft of vertical layout, arranged by the side of the reactor and the turbo-compressor rotary speed was selected to be 250 s -1 (15000 r/min) by considering the efficiency of turbo-compressor blade systems, the strength conditions and the mass and size characteristics of the turbo-compressor. The rotor system will be supported by electromagnetic bearings (EMBs) to curb the possible pollutions of the primary loop. Of all the components in this design, the high speed turbo-generator seems to be a world-wide technical nut. As an alternative design, a gearbox complex is used to reduce the rotary speed from the turbo-compressor 250 s -1 to 50 s -1 so that the ordinary generator can be used. (authors)

  19. Magnetic resonance imaging of the cranial nerves in the posterior fossa: a comparative study of t2-weighted spin-echo sequences at 1.5 and 3.0 tesla.

    Science.gov (United States)

    Fischbach, F; Müller, M; Bruhn, H

    2008-04-01

    High-field magnetic resonance imaging (MRI) at 3.0 Tesla (T) is rapidly gaining clinical acceptance. Whether doubling of the field strength of 1.5T and the subsequent increase in signal-to-noise ratio (SNR) leads to a significant improvement of image quality is not automatically given. To evaluate the depiction of fine anatomic detail in the posterior fossa, focusing on brain nerves, on T2-weighted imaging, and to define the potential advantage of imaging at 3.0T versus 1.5T. In total, 10 brainstem nerve pairs of 12 volunteers were identified on T2-weighted MR images of 2- and 5-mm section thickness acquired at 1.5T and 3.0T. The MR images were compared for each subject at both field strengths by three independent readers who rated image quality according to depiction of anatomic detail and contrast by using a rating scale. In general, MR images at 3.0T were considered more conspicuous and less noisy than images at 1.5T. The SNR value measured was almost doubled. With respect to structural identification and contrast according to the rating scale, observer scores were significantly improved both for standard imaging with 5-mm sections and high-resolution imaging with 2-mm sections at 3.0T. Direct comparison revealed a significant increase for evaluated image quality criteria and the number of nerves detected. The comparison revealed a clear advantage in favor of T2-weighted MRI at 3.0T vs. 1.5T in depicting the roots and course of brain nerves in the posterior fossa.

  20. Comparison of spin-echo and gradient recalled echo T1 weighted MR images for quantitative voxel-based clinical brain research

    International Nuclear Information System (INIS)

    Barnden, L.R.; Crouch, B.

    2010-01-01

    Full text: New methods to normalise inter-subject global variations in T 1 -weighted MR (T I w) signal levels have permitted their use in voxel based population studies of brain dysfunction. Here we address the question of whether a spin-echo (SE) or a gradient recalled echo (GRE) T I w sequence is better for this purpose. GRE images are commonly referred to as 3D MRL SE has superior signal/noise properties to GRE but is slower to acquire so that typical slice thicknesses are 3-5 mm compared to 1-2 mm for GRE. GRE has better grey/white matter contrast which should permit better spatial normalization. However, unlike SE, GRE is affected by subject-specific magnetic field inhomogeneities that distort the images. We acquired T I brain images for 25 chronic fatigue syndrome (CFS) patients and 25 normal controls (NC) with TRITE/flip-angle of 600 ms/l5 ms/90 deg for SE and 5.76 ms/1.9 ms/9 deg for GRE. For GRE, the magnetic field inhomogeneity related signal level distortions could be corrected, but not the spatial distortions. After spatial normalization we subjected them to voxel-based statistical analysis with adjustment for global signal level using the SPM5 package. Initially, the same spatial normalization deformations were applied to both SE and GRE after coregistering them. Although the SPM regressions of SE and GRE yielded similar spatial distributions of significance, the SE regressions were consistently statistically stronger. For example, in one strong regression, the corrected cluster P value was twenty times stronger (I.Oe-5 versus I.Oe-3). T I w SE have proved better than T I GRE images in quantitative analysis in a clinical research study. (author)

  1. Signatures of spin-orbital states of t2g 2 system in optical conductivity: R VO3 (R =Y and La)

    Science.gov (United States)

    Kim, Minjae

    2018-04-01

    We investigate signatures of the spin and orbital states of R VO3 (R =Y and La) in optical conductivity using density functional theory plus dynamical mean-field theory (DFT+DMFT). From the assignment of multiplet state configurations to optical transitions, the DFT+DMFT reproduces experimental temperature-dependent evolutions of optical conductivity for both YVO3 and LaVO3. We also show that the optical conductivity is a useful quantity to probe the evolution of the orbital state even in the absence of spin order. The result provides a reference to investigate the spin and orbital states of t2g 2 vanadate systems, which is an important issue for both fundamental physics on spin and orbital states and applications of vanadates by means of orbital state control.

  2. Morphological and functional MR imaging of the pharyngotympanic tube

    International Nuclear Information System (INIS)

    Krombach, G.A.; Nolte-Ernsting, C.; Schmitz-Rode, T.; Guenther, R.W.; Di Martino, E.; Westhofen, M.; Prescher, A.

    2000-01-01

    Purpose: To develop and evaluate a protocol for the anatomic depiction and functional testing of the auditory tube with the use of MR imaging. Methods: Eleven volunteers were included into this study. For the morphological assessment, the imaging protocol included axial and coronal T 2 -weighted turbo-spin echo sequences (T R /T E =3194/100 ms) and a T 1 -weighted gradient echo sequence (T R /T E =42/4.6 ms). For the functional test a dynamic turbo-gradient echo sequence (TFE) with spectral fat suppression (T R /T E =15/6,2 ms; 4 sec) was obtained using the single slice technique before and during the Valsalva manoeuvre. Results: With multi-slice sequences, the osseous part of the auditory tube, the tubal cartilage (middle and lateral lamina), the ciliated epithelium, Ostmann's adipose body and the levator and tensor veli palatini muscles were delineated in all cases. During the Valsalva test, opening of the auditory tube was demonstrated in 20 of the 22 investigated sides using the dynamic TFE single slice sequence. Conclusions: The introduced MRI protocol allow visualization of the opening of the auditory tube and provides detailed anatomical information of the nasopharynx. Comprehensive morphological and functional evaluation of the auditory tube becomes possible within a single examination. (orig.) [de

  3. List manipulation in Turbo Prolog

    Directory of Open Access Journals (Sweden)

    V.Cotelea

    1995-06-01

    Full Text Available The present paper is concerned with list processing in Turbo Prolog language. It doesn't claim to be an exhaustive description of operations which can be performed upon lists. Nevertheless adduced programs are most representative, more or less known to specialists in logic programming domain. By means of examples are explained the list manipulation techniques, use of recursion, declarative comparison of predicates, analysis and fixation of acceptable prototypes and some problems of predicates' inconsistency. Index terms. Prolog, list, recursion.

  4. Notes on T-invariance and polarization effects in the elastic scattering of a particle with spin 1/2 on the unpolarized target

    International Nuclear Information System (INIS)

    Lyuboshits, V.V.; Lyuboshits, V.L.

    1998-01-01

    In the frames of T-invariance the analysis of the general dependence of the elastic scattering effective cross section of a particle with spin 1/2 on the unpolarized target with arbitrary spin upon the initial and final polarizations of the particle has been performed. On the base of the T-symmetry of the differential scattering cross section only, without traditional consideration of the spin structure of scattering amplitudes, a simple proof of the Wolfenstein theorem is obtained (this theorem states that the degree of transverse polarization, arising in the elastic scattering of an unpolarized particle on the unpolarized target, is equal to the coefficient of left-right asymmetry in the elastic scattering of the same but transversally polarized particle on the same target). Meantime, it is ascertained that in the case of P-parity violation (conserving T-invariance) there exists no analogous universal relation between the degree of longitudinal polarization and the coefficient of P-odd spin asymmetry in the scattering of longitudinally polarized particles. It is shown, further, that under T-invariance the amplitude and cross section of 'backward' scattering of neutrons on zero-spin nuclei do not depend on spin, and the observation of such a dependence would testify unambiguously to the T-invariance violation. However, according to the fulfilled estimates, the T-noninvariant spin asymmetry in the 'backward' scattering is very small (about 10 -8 - 10 -7 )

  5. Intracranial arterial wall enhancement using gadolinium-enhanced 3D black-blood T1-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Takano, Koichi, E-mail: k-takano@fukuoka-u.ac.jp; Hida, Kosuke; Kuwabara, Yasuo; Yoshimitsu, Kengo

    2017-01-15

    Purpose: We investigated the enhancement of the intracranial arterial walls with gadolinium-enhanced, black-blood three-dimensional T1-weighted imaging (Gd-3DBB) by using an improved motion-sensitized driven-equilibrium (iMSDE)—prepared volumetric isotropic turbo spin-echo acquisition (VISTA). Methods: A total of 115 patients underwent FLAIR, 3D-TOF-MRA and Gd-3DBB with a 1.5-T scanner. The degree and distribution of the arterial wall enhancement on Gd-3DBB was assessed. The association of the degree of wall enhancement with brain infarction/ischemic lesions on FLAIR, luminal changes on 3D-TOF-MRA, and cardiovascular risk factors (CVRFs) was investigated by univariate and multiple logistic regression analyses. Results: Strong enhancement of the arterial walls was observed in 77 vertebral arteries (33.5%), 4 basilar arteries (3.5%), 31 supraclinoid internal carotid arteries (ICAs) (13.5%) and 8 middle cerebral arteries (3.5%). In addition, 221 intrapetrous ICAs (96.1%) showed strong enhancement. After adjusting for confounding factors, multivariate analyses showed that the patient age was independently associated with the strong wall enhancement of the arteries for both the posterior (OR, 1.088; 95% CI, 1.034–1.146) and the anterior circulation (OR, 1.098, 95% CI 1.029–1.172). In addition, the presence of the supratentorial brain infarctions was independently associated with the strong wall enhancement in the anterior circulation excluding the intrapetrous ICAs (OR, 4.097; 95% CI, 1.483–11.319). Conclusions: Although the arterial wall enhancement on the Gd-3DBB probably reflects normal aging, the enhancement in the anterior circulation might be related to brain infarctions. On the other hand, the intrapetrous ICA enhancement is considered a nonspecific finding and should not be mistaken for arterial pathologies such as atherosclerosis or arteritis.

  6. Intracranial arterial wall enhancement using gadolinium-enhanced 3D black-blood T1-weighted imaging

    International Nuclear Information System (INIS)

    Takano, Koichi; Hida, Kosuke; Kuwabara, Yasuo; Yoshimitsu, Kengo

    2017-01-01

    Purpose: We investigated the enhancement of the intracranial arterial walls with gadolinium-enhanced, black-blood three-dimensional T1-weighted imaging (Gd-3DBB) by using an improved motion-sensitized driven-equilibrium (iMSDE)—prepared volumetric isotropic turbo spin-echo acquisition (VISTA). Methods: A total of 115 patients underwent FLAIR, 3D-TOF-MRA and Gd-3DBB with a 1.5-T scanner. The degree and distribution of the arterial wall enhancement on Gd-3DBB was assessed. The association of the degree of wall enhancement with brain infarction/ischemic lesions on FLAIR, luminal changes on 3D-TOF-MRA, and cardiovascular risk factors (CVRFs) was investigated by univariate and multiple logistic regression analyses. Results: Strong enhancement of the arterial walls was observed in 77 vertebral arteries (33.5%), 4 basilar arteries (3.5%), 31 supraclinoid internal carotid arteries (ICAs) (13.5%) and 8 middle cerebral arteries (3.5%). In addition, 221 intrapetrous ICAs (96.1%) showed strong enhancement. After adjusting for confounding factors, multivariate analyses showed that the patient age was independently associated with the strong wall enhancement of the arteries for both the posterior (OR, 1.088; 95% CI, 1.034–1.146) and the anterior circulation (OR, 1.098, 95% CI 1.029–1.172). In addition, the presence of the supratentorial brain infarctions was independently associated with the strong wall enhancement in the anterior circulation excluding the intrapetrous ICAs (OR, 4.097; 95% CI, 1.483–11.319). Conclusions: Although the arterial wall enhancement on the Gd-3DBB probably reflects normal aging, the enhancement in the anterior circulation might be related to brain infarctions. On the other hand, the intrapetrous ICA enhancement is considered a nonspecific finding and should not be mistaken for arterial pathologies such as atherosclerosis or arteritis.

  7. PERFORMANCE EVALUATION OF TURBO CODED OFDM SYSTEMS AND APPLICATION OF TURBO DECODING FOR IMPULSIVE CHANNEL

    Directory of Open Access Journals (Sweden)

    Savitha H. M.

    2010-09-01

    Full Text Available A comparison of the performance of hard and soft-decision turbo coded Orthogonal Frequency Division Multiplexing systems with Quadrature Phase Shift Keying (QPSK and 16-Quadrature Amplitude Modulation (16-QAM is considered in the first section of this paper. The results show that the soft-decision method greatly outperforms the hard-decision method. The complexity of the demapper is reduced with the use of simplified algorithm for 16-QAM demapping. In the later part of the paper, we consider the transmission of data over additive white class A noise (AWAN channel, using turbo coded QPSK and 16-QAM systems. We propose a novel turbo decoding scheme for AWAN channel. Also we compare the performance of turbo coded systems with QPSK and 16-QAM on AWAN channel with two different channel values- one computed as per additive white Gaussian noise (AWGN channel conditions and the other as per AWAN channel conditions. The results show that the use of appropriate channel value in turbo decoding helps to combat the impulsive noise more effectively. The proposed model for AWAN channel exhibits comparable Bit error rate (BER performance as compared to AWGN channel.

  8. Contrast-enhanced dynamic MR nephrography using the TurboFLASH navigator-gating technique in children

    International Nuclear Information System (INIS)

    Boss, Andreas; Schaefer, Juergen F.; Claussen, Claus D.; Kueper, Klaus; Schlemmer, Heinz-Peter; Martirosian, Petros; Schick, Fritz; Hacker, Hans-Walter; Darge, Kassa

    2006-01-01

    The purpose of this work was to test the feasibility of an MR examination protocol for the comprehensive assessment of renal morphology, excretion and split renal function using a navigator-gated TurboFLASH sequence. A navigator-gated T1-weighted single-slice TurboFLASH sequence suitable for dynamic MR urography and nephrography was implemented. A protocol was developed allowing for assessment of urinary excretion and split renal function by recording the renal clearance of a gadolinium (Gd) diethylene-triamine-pentacetic-acid (DTPA) bolus. Ten patients aged between 14 months and 14 years (mean age 4.8±4.6 years) were evaluated with the following indications: pelvicalyceal dilatation (n=4), follow-up after pyeloplasty (n=1), duplex systems (n=3), large renal cyst (n=1), and renal insufficiency (n=1). Dynamic MR urography and MR split renal function were compared to MAG3 scintigraphy. Evaluation of morphology, excretion and function required 50-60 minutes examination time, plus 10 minutes for post-processing. The TurboFLASH sequence yielded image acquisition at nearly identical diaphragm positions allowing for accurate region-of-interest evaluation within the renal parenchyma and the urinary passage. Static and dynamic MR urography showed the morphology of the urinary tract and excretion with sufficient diagnostic imaging quality, and the results were in diagnostic compliance with scintigraphy. MRI and scintigraphy yielded similar results for split renal function with a correlation coefficient of R=0.968 determined by linear regression. Our conclusions were that the method is robust, easy to perform on a clinical 1.5 T MRI system, rapid to evaluate and post-process and, therefore, easy to incorporate into clinical routine. Compared to scintigraphy, the higher spatial resolution of the MR examination provides additional important information improving the management of the pediatric patients without the application of radioactive tracers. (orig.)

  9. Magnetic resonance enteroclysis in patients with Crohn's disease: fat saturated T2-weighted sequences for evaluation of inflammatory activity.

    Science.gov (United States)

    Grieser, Christian; Denecke, Timm; Steffen, Ingo G; Werner, Scarlett; Kröncke, Thomas; Guckelberger, Olaf; Pape, Ulrich-Frank; Meier, Johannes; Thiel, Regina; Kivelitz, Dietmar; Sturm, Andreas; Hamm, Bernd; Röttgen, Rainer

    2012-04-01

    To evaluate fat saturated (fs) T2-weighted (w) fast relaxation fast spin echo (FRFSE)-sequences compared to the standard protocol with contrast agent for the evaluation of inflammatory activity in patients with Crohn's Disease (CD). Fourty-eight patients (male, 17; female, 33; mean age, 37 years) with suspicion of inflammatory activity in proven CD who underwent MR enteroclysis (MRE) at 1.5T (GE Healthcare) were retrospectively included. Two blinded radiologists analyzed MRE images for presence and extent of CD lesions and degree of local inflammation for fsT2-w FRFSE and contrast enhanced T1-w images (T2-activity; T1-activity; score, 1-4) in consensus. Furthermore, mural signal intensity (SI) ratios (T2-ratio; T1-ratio) were recorded. Patient based MRE findings were correlated with endoscopic (45 patients), surgical (6 patients), histopathological, and clinical data (CDAI) as a surrogate reference standard. In total, 24 of 48 eligible patients presented with acute inflammatory activity with 123 affected bowel segments. ROC analysis of the total inflammatory score presented an AUC of 0.93 (pT2-activity (T1-activity, AUC 0.63; p=0.019). ROC analysis revealed an AUC of 0.76 (pT2-ratio (T1-ratio, AUC 0.51; p=0.93). General linear regression model revealed T2-activity (p=0.001) and age (p=0.024) as predictive factors of acute bowel inflammation. T2-w FRFSE-sequences can depict CD lesions and help to assess the inflammation activity, even with improved accuracy as compared to contrast-enhanced T1-w sequences. Copyright © 2011 European Crohn's and Colitis Organisation. Published by Elsevier B.V. All rights reserved.

  10. High-intensity facial nerve lesions on T2-weighted images in chronic persistent facial nerve palsy

    Energy Technology Data Exchange (ETDEWEB)

    Kinoshita, T. [Dept. of Radiology, Sendai City Hospital, Sendai (Japan); Dept. of Radiology, Tottori Univ. (Japan); Ishii, K. [Dept. of Radiology, Sendai City Hospital, Sendai (Japan); Okitsu, T. [Dept. of Otolaryngology, Sendai City Hospital (Japan); Ogawa, T. [Dept. of Radiology, Tottori Univ. (Japan); Okudera, T. [Dept. of Radiology, Research Inst. of Brain and Blood Vessels-Akita, Akita (Japan)

    2001-05-01

    Our aim was to estimate the value of MRI in detecting irreversibly paralysed facial nerves. We examined 95 consecutive patients with a facial nerve palsy (14 with a persistent palsy, and 81 with good recovery), using a 1.0 T unit, with T2-weighted and contrast-enhanced T1-weighted images. The geniculate ganglion and tympanic segment had gave high signal on T2-weighted images in the chronic stage of persistent palsy, but not in acute palsy. The enhancement pattern of the facial nerve in the chronic persistent facial nerve palsy is similar to that in the acute palsy with good recovery. These findings suggest that T2-weighted MRI can be used to show severely damaged facial nerves. (orig.)

  11. T2-enhanced tensor diffusion trace-weighted image in the detection of hyper-acute cerebral infarction: Comparison with isotropic diffusion-weighted image

    International Nuclear Information System (INIS)

    Chou, M.-C.; Tzeng, W.-S.; Chung, H.-W.; Wang, C.-Y.; Liu, H.-S.; Juan, C.-J.; Lo, C.-P.; Hsueh, C.-J.; Chen, C.-Y.

    2010-01-01

    Background and purpose: Although isotropic diffusion-weighted imaging (isoDWI) is very sensitive to the detection of acute ischemic stroke, it may occasionally show diffusion negative result in hyper-acute stroke. We hypothesize that high diffusion contrast diffusion trace-weighted image with enhanced T2 may improve stroke lesion conspicuity. Methods: Five hyper acute stroke patients (M:F = 0:5, average age = 61.8 ± 20.5 y/o) and 16 acute stroke patients (M:F = 11:5, average age = 67.7 ± 12 y/o) were examined six-direction tensor DWIs at b = 707 s/mm 2 . Three different diffusion-weighted images, including isotropic (isoDWI), diffusion trace-weighted image (trDWI) and T2-enhanced diffusion trace-weighted image (T2E t rDWI), were generated. Normalized lesion-to-normal ratio (nLNR) and contrast-to-noise ratio (CNR) of three diffusion images were calculated from each patient and statistically compared. Results: The trDWI shows better nLNR than isoDWI on both hyper-acute and acute stroke lesions, whereas no significant improvement in CNR. Nevertheless, the T2E t rDWI has statistically superior CNR and nLNR than those of isoDWI and trDWI in both hyper-acute and acute stroke. Conclusions: We concluded that tensor diffusion trace-weighted image with T2 enhancement is more sensitive to stroke lesion detection, and can provide higher lesion conspicuity than the conventional isotropic DWI for early stroke lesion delineation without the need of high-b-value technique.

  12. Bilateral hyperintense basal ganglia on T1-weighted image

    International Nuclear Information System (INIS)

    Baik, Seung Kug; Ahn, Woo Hyun; Choi, Han Yong; Kim, Bong Gi

    1994-01-01

    Bilateral high signal intensity in basal ganglia on T1-weighted images is unusual, the purpose of this study is to describe the pattern of high signal intensity and underlying disease. During the last three years, 8 patients showed bilateral high signal intensity in basal ganglia on T1-weighted image, as compared with cerebral white matter. Authors analyzed the images and underlying causes retrospectively. Of 8 patients, 5 were male and 3 were female. The age ranged from 15 days to 79 years. All patient were examined by a 0.5T superconductive MRI. Images were obtained by spin echo multislice technique. Underlying causes were 4 cases of hepatopathy, 2 cases of calcium metabolism disorder, and one case each of neurofibromatosis and hypoxic brain injury. These process were bilateral in all cases and usually symmetric. In all cases the hyperintense areas were generally homogenous without mass effect or edema, although somewhat nodular appearance was seen in neurofibromatosis. Lesions were located in the globus pallidus and internal capsule in hepatopathy and neurofibromatosis, head of the caudate nucleus in disorder of calcum metabolism, and the globus pallidus in hypoxic brain injury. Although this study is limited by its patient population, bilateral hyperintense basal ganglia is associated with various disease entities. On analysis of hyperintense basal ganglia lesion, the knowledge of clinical information improved diagnostic accuracy

  13. Optimized T1- and T2-weighted volumetric brain imaging as a diagnostic tool in very preterm neonates

    International Nuclear Information System (INIS)

    Nossin-Manor, Revital; Chung, Andrew D.; Morris, Drew; Thomas, Bejoy; Shroff, Manohar M.; Soares-Fernandes, Joao P.; Cheng, Hai-Ling M.; Whyte, Hilary E.A.; Taylor, Margot J.; Sled, John G.

    2011-01-01

    T1- and T2-W MR sequences used for obtaining diagnostic information and morphometric measurements in the neonatal brain are frequently acquired using different imaging protocols. Optimizing one protocol for obtaining both kinds of information is valuable. To determine whether high-resolution T1- and T2-W volumetric sequences optimized for preterm brain imaging could provide both diagnostic and morphometric value. Thirty preterm neonates born between 24 and 32 weeks' gestational age were scanned during the first 2 weeks after birth. T1- and T2-W high-resolution sequences were optimized in terms of signal-to-noise ratio, contrast-to-noise ratio and scan time and compared to conventional spin-echo-based sequences. No differences were found between conventional and high-resolution T1-W sequences for diagnostic confidence, image quality and motion artifacts. A preference for conventional over high-resolution T2-W sequences for image quality was observed. High-resolution T1 images provided better delineation of thalamic myelination and the superior temporal sulcus. No differences were found for detection of myelination and sulcation using conventional and high-resolution T2-W images. High-resolution T1- and T2-W volumetric sequences can be used in clinical MRI in the very preterm brain to provide both diagnostic and morphometric information. (orig.)

  14. MR urography (MRU) of non-dilated ureter with diuretic administration: Static fluid 2D FSE T2-weighted versus 3D gadolinium T1-weighted GE excretory MR

    International Nuclear Information System (INIS)

    Roy, C.; Ohana, M.; Host, Ph.; Alemann, G.; Labani, A.; Wattiez, A.; Lang, H.

    2014-01-01

    T2w-MRU with multiple orientations and diuretic is sufficient to identify non-dilated ureter.•T2w-MRU offers information on ureteral contractions and could be proposed to detect initial obstruction before hydronephrosis occurs (for instance in cases of endometriosis).•T2w-MRU could also be used to evaluate potential renal donors or in patients unable to receive gadolinium.•CE-MRU rapidly produces an overdistended bladder with a risk of false positive diagnosis of mild obstruction.•CE-MRU is less convenient for patients. T2w-MRU with multiple orientations and diuretic is sufficient to identify non-dilated ureter. T2w-MRU offers information on ureteral contractions and could be proposed to detect initial obstruction before hydronephrosis occurs (for instance in cases of endometriosis). T2w-MRU could also be used to evaluate potential renal donors or in patients unable to receive gadolinium. CE-MRU rapidly produces an overdistended bladder with a risk of false positive diagnosis of mild obstruction. CE-MRU is less convenient for patients. The goal of this prospective study was to compare the efficiency of two types of MRU after diuretic administration to identify the non-dilated ureter. MR pelvic examinations were performed in 126 patients after receiving furosemide. Each patient underwent in addition to their protocol for context, two types of MRU: 2D T2-weighted FSE (T2w-MRU) and 3D Gd T1-weighted GE (CE-MRU). Four segments were checked for each ureter. For the first part of the analysis, readers evaluated the whole image quality using a four points subjective scale and for the second part, they were asked to score separately each ureteral segment as present or absent. 1008 ureteral segments were checked. For the image quality, readers did not find any significant difference (3.8 ± 0.5 vs 3.6 ± 0.7, p value: 0.13) between MRU methods. The interobserver agreement was excellent with a κ correlation coefficient as high as 0.89 for T2w-MRU and 0.92 for CE

  15. Comparative study of fast T 2-weighted images using respiratory triggered, breath-hold, fat suppression and phased array multi coil for liver evaluation by magnetic resonance imaging; Estudo comparativo das sequencias rapidas ponderadas em T2, utilizando-se sincronizacao respiratoria, apneia, supressao de gordura, bobina de corpo e bobina de sinergia para a avaliacao do figado pela ressonancia magnetica

    Energy Technology Data Exchange (ETDEWEB)

    Abbehusen, Cristiane L.; D' Ippolito, Giuseppe; Palacio, Glaucia A.S.; Szejnfeld, Jacob [Universidade Federal de Sao Paulo (UNIFESP), SP (Brazil). Escola Paulista de Medicina (EPM). Dept. de Diagnostico por Imagem]. E-mail: cabbehusen@hotmail.com

    2003-10-01

    The objective of this study was to compare both qualitatively and quantitatively six T 2-weighted turbo spin-echo sequences varying the respiratory compensation technique, associating or not fat tissue suppression and using different types of coils. We performed a prospective study of 71 consecutive patients that were submitted to MRI of the liver using a 1.5 T magnet. The six following pulse sequences were used: fat-suppressed respiratory triggered with conventional body coil; breath-hold fat-suppressed with conventional body coil; non-suppressed respiratory triggered with conventional body coil; breath-hold non fat-suppressed with conventional body coil; fat-suppressed respiratory triggered with phased-array multi coil; breath-hold fat-suppressed with phased-array multi coil. Images were analyzed quantitatively by measuring the signal-to-noise ratios and qualitatively by evaluating the sharpness of hepatic contours, visibility of intrahepatic vessels and other segmental landmarks, and the presence of artifacts. Results: the qualitative analysis showed that the mean values obtained with the six sequences were 7.8, 4.6, 7.9, 5.2, 6.7 and 4.6 respectively. The respiratory-triggered sequences were better than the breath-hold sequences in both qualitative and quantitative analysis (p < 0.001). No significant differences in the values of signal-to-noise ratios and in overall image quality were found between the sequences with and without fat suppression (p . 0.05). The sequences using the body coil were similar in terms of image quality (p . 0.05) and better regarding signal-to-noise ratios than those obtained with the phased=array multi coil (p ,0.001). Our qualitative and quantitative results suggest that the best MRI sequences for the valuation of the liver are the sequences with respiratory triggering using a conventional body coil, with or without fat suppression. (author)

  16. Mapping pathological changes in brain structure by combining T1- and T2-weighted MR imaging data

    International Nuclear Information System (INIS)

    Ganzetti, Marco; Mantini, Dante; Wenderoth, Nicole

    2015-01-01

    A workflow based on the ratio between standardized T1-weighted (T1-w) and T2-weighted (T2-w) MR images has been proposed as a new tool to study brain structure. This approach was previously used to map structural properties in the healthy brain. Here, we evaluate whether the T1-w/T2-w approach can support the assessment of structural impairments in the diseased brain. We use schizophrenia data to demonstrate the potential clinical utility of the technique. We analyzed T1-w and T2-w images of 36 schizophrenic patients and 35 age-matched controls. These were collected for the Function Biomedical Informatics Research Network (fBIRN) collaborative project, which had an IRB approval and followed the HIPAA guidelines. We computed T1-w/T2-w images for each individual and compared intensities in schizophrenic and control groups on a voxel-wise basis, as well as in regions of interest (ROIs). Our results revealed that the T1-w/T2-w image permits to discriminate brain regions showing group-level differences between patients and controls with greater accuracy than conventional T1-w and T2-w images. Both the ROIs and the voxel-wise analysis showed globally reduced gray and white matter values in patients compared to controls. Significantly reduced values were found in regions such as insula, primary auditory cortex, hippocampus, inferior longitudinal fasciculus, and inferior fronto-occipital fasciculus. Our findings were consistent with previous meta-analyses in schizophrenia corroborating the hypothesis of a potential ''disconnection'' syndrome in conjunction with structural alterations in local gray matter regions. Overall, our study suggested that the T1-w/T2-w technique permits to reliably map structural differences between the brains of patients and healthy individuals. (orig.)

  17. Mapping pathological changes in brain structure by combining T1- and T2-weighted MR imaging data

    Energy Technology Data Exchange (ETDEWEB)

    Ganzetti, Marco; Mantini, Dante [ETH Zurich, Neural Control of Movement Laboratory, Department of Health Sciences and Technology, Zurich (Switzerland); University of Oxford, Department of Experimental Psychology, Oxford (United Kingdom); Wenderoth, Nicole [ETH Zurich, Neural Control of Movement Laboratory, Department of Health Sciences and Technology, Zurich (Switzerland); KU Leuven, Laboratory of Movement Control and Neuroplasticity, Faculty of Kinesiology and Rehabilitation Sciences, Leuven (Belgium)

    2015-09-15

    A workflow based on the ratio between standardized T1-weighted (T1-w) and T2-weighted (T2-w) MR images has been proposed as a new tool to study brain structure. This approach was previously used to map structural properties in the healthy brain. Here, we evaluate whether the T1-w/T2-w approach can support the assessment of structural impairments in the diseased brain. We use schizophrenia data to demonstrate the potential clinical utility of the technique. We analyzed T1-w and T2-w images of 36 schizophrenic patients and 35 age-matched controls. These were collected for the Function Biomedical Informatics Research Network (fBIRN) collaborative project, which had an IRB approval and followed the HIPAA guidelines. We computed T1-w/T2-w images for each individual and compared intensities in schizophrenic and control groups on a voxel-wise basis, as well as in regions of interest (ROIs). Our results revealed that the T1-w/T2-w image permits to discriminate brain regions showing group-level differences between patients and controls with greater accuracy than conventional T1-w and T2-w images. Both the ROIs and the voxel-wise analysis showed globally reduced gray and white matter values in patients compared to controls. Significantly reduced values were found in regions such as insula, primary auditory cortex, hippocampus, inferior longitudinal fasciculus, and inferior fronto-occipital fasciculus. Our findings were consistent with previous meta-analyses in schizophrenia corroborating the hypothesis of a potential ''disconnection'' syndrome in conjunction with structural alterations in local gray matter regions. Overall, our study suggested that the T1-w/T2-w technique permits to reliably map structural differences between the brains of patients and healthy individuals. (orig.)

  18. 3T MR Spin Echo T1 Weighted Image at Optimization of Flip Angle

    International Nuclear Information System (INIS)

    Lim, Chung Hwang; Bae, Sung Jin

    2009-01-01

    This study presents the optimization of flip angle (FA) to obtain higher contrast to noise ratio (CNR) and lower specific absorption rate (SAR). T1-weighted images of the cerebrum of brain were obtained from 50 degrees to 130 degrees FA with 10 interval. Signal to noise ratios (SNRs) were calculated for white matter (WM), gray matter (GM), and background noise. The proper FA was analyzed by T-test statistics and Kruskal-wallis analysis using R1 = 1- exp (-TR/T1) and Ernst angle cos = exp ((-TR/T1). The SNR of WM at 130 degrees FA is approximately 1.6 times higher than the SNR of WM at 50 degrees. The SNR of GM at 130 degrees FA is approximately 1.9 times higher than the SNR of GM at 50 degrees. Although the SNRs of WM and GM showed similar trends with the change of FA values, the slowdown point of decrease after linear fitting were different. While the SNR of WM started decreasing at 120 degrees FA, the SNR of GM started decreasing at less than 110 degrees. The highest SNRs of WM and GM were obtained at 130 degrees FA. The highest CNRs, however, were obtained at 80 degrees FA. Although SNR increased with the change of FA values from 50 degrees to 130 degrees at 3T SE T1WI, CNR was higher at 80 degrees FA than at the usually used 90 degrees FA. In addition, the SAR was decreased by using smaller FA. The CNR can be increased by using this optimized FA at 3T MR SE T1WI.

  19. MRI of the liver with the new contrast medium Gd-BOPTA

    International Nuclear Information System (INIS)

    Vogl, T.J.; Pegios, W.; Balzer, J.; Lissner, J.; Pirovano, G.

    1992-01-01

    A phase 1 study on 8 normals has been carried out to determine the effectiveness and safety during MRI of a new hepatobiliary contrast medium Gd-BOPTA for causing enhancement of the upper abdominal organs. Gradient echo sequences (flash), T 1 and T 2 -weighted spin echo sequences and turbo-flash sequences were used. The contrast medium was given as a single infusion in various concentrations (0.005, 0.05, 0.1 and 0.2 mmol/kg body weight). Optimal contrast of liver parenchyma was obtained with a dose of 0.05-0.1 mmol/kg body weight, resulting in contrast increase of 149.1% during gradient echo sequences and 107.8% during T 1 spin echo sequences. In general, the increased contrast lasted for about two hours. Because of the biliary and renal excretion there was an enormous increase in signal intensity of the bile ducts and a significant increase in the kidneys and ureters. The results of the first in-vivo-trial of Gd-BOPTA encourages the performance of further clinical studies of this new hepatobiliary contrast medium. (orig.) [de

  20. MR imaging of skeletal muscle injury in rabbit : comparison between diffusion and T2-weighted MR images

    International Nuclear Information System (INIS)

    Kim, Ki Jun; Lee, Sung Yong; Lee, Jae Hee; Kwon Oh Han; Lee, Jae Mun; Lim, Yeon Soo

    2000-01-01

    The purpose of this study was to apply the diffusion-weighted MR imaging technique to the early detection of skeletal muscle injury and to evaluate the usefulness of this imaging sequence. Thirty rabbits, divided into two groups, were included in this study . Skeletal muscle injury was experimentally induced in the right thigh muscles of each rabbit by clamping with a hemostat for one minute. Four-stage clamping was applied to the rabbits in group I, but for group II there was only one stage. Diffusion and T2-weighted MR images were obtained using a 1.5T MR unit. Serial 5-and 30-minute, and 2-, 24-, and 48- hour delayed images were obtained after injury. The initial time of signal intensity change was recorded and the signal intensities of the injured sites and corresponding normal sites were measured and compared. On 5-minute delayed images in group I, diffusion-weighted MR images showed signal intensity changes in injured muscle in all 15 cases, but on T2-weighted images, change was not detected in three cases. In group II, 5-minute delayed T2-weighted images failed to depict the lesion in six cases, but on diffusion-weighted images, all lesions were detected. In addition, one lesion was not detected on 30-minute delayed T2-weighted images. In group II, the sensitivity of lesion detection was significantly higher on diffusion-weighted than on T2-weighted images (p=3D0.0169). Diffusion-weighted MR imaging was shown to be more sensitive than T2-weighted imaging for the detection of signal intensity changes immediately after artificial injury, especially when this was of a lesser degree. These results suggest that diffusion-weighted MR imaging may be useful for the detection of early stage skeletal muscle injury. (author)

  1. Superconductivity and spin gap in the zigzag-chain t-J model simulating a CuO double chain in Pr2Ba4Cu7O15-δ

    International Nuclear Information System (INIS)

    Sano, Kazuhiro; Ono, Yoshiaki

    2007-01-01

    Using the numerical diagonalization method, we examine the one-dimensional t 1 -t 2 -J 1 -J 2 model (zigzag-chain t-J model) which is an effective model for metallic CuO double chains in the super-conductor Pr 2 Ba 4 Cu 7 O 15-δ . Based on the Tomonaga-Luttinger liquid theory, we calculate the Luttinger liquid parameter K ρ as a function of the electron density n. It is found that superconductivity is realized in the parameter region, which is in accordance with experimental results. We show the phase diagram of a spin gap in the t 2 /|t 1 |-n plane by analyzing the expectation value of the twist operator Z σ in the spin sector. The spin gap appears in the region with a large t 2 /|t 1 |, where the phase boundary at half filling is consistent with that of the known frustrated quantum spin system. The analysis also suggests that the estimated value of the spin gap reaches ∼100 K in the realistic parameter region of Pr 2 Ba 4 Cu 7 O 15-δ . (author)

  2. The image evaluation of iterative motion correction reconstruction algorithm PROPELLER T2-weighted imaging compared with MultiVane T2-weighted imaging

    Science.gov (United States)

    Lee, Suk-Jun; Yu, Seung-Man

    2017-08-01

    The purpose of this study was to evaluate the usefulness and clinical applications of MultiVaneXD which was applying iterative motion correction reconstruction algorithm T2-weighted images compared with MultiVane images taken with a 3T MRI. A total of 20 patients with suspected pathologies of the liver and pancreatic-biliary system based on clinical and laboratory findings underwent upper abdominal MRI, acquired using the MultiVane and MultiVaneXD techniques. Two reviewers analyzed the MultiVane and MultiVaneXD T2-weighted images qualitatively and quantitatively. Each reviewer evaluated vessel conspicuity by observing motion artifacts and the sharpness of the portal vein, hepatic vein, and upper organs. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated by one reviewer for quantitative analysis. The interclass correlation coefficient was evaluated to measure inter-observer reliability. There were significant differences between MultiVane and MultiVaneXD in motion artifact evaluation. Furthermore, MultiVane was given a better score than MultiVaneXD in abdominal organ sharpness and vessel conspicuity, but the difference was insignificant. The reliability coefficient values were over 0.8 in every evaluation. MultiVaneXD (2.12) showed a higher value than did MultiVane (1.98), but the difference was insignificant ( p = 0.135). MultiVaneXD is a motion correction method that is more advanced than MultiVane, and it produced an increased SNR, resulting in a greater ability to detect focal abdominal lesions.

  3. Computer-assisted analysis of peripheral zone prostate lesions using T2-weighted and dynamic contrast enhanced T1-weighted MRI

    Energy Technology Data Exchange (ETDEWEB)

    Vos, Pieter C; Hambrock, Thomas; Barenstz, Jelle O; Huisman, Henkjan J [Department of Radiology, Radboud University Medical Centre, Nijmegen, 6525GA (Netherlands)], E-mail: p.vos@rad.umcn.nl

    2010-03-21

    In this study, computer-assisted analysis of prostate lesions was researched by combining information from two different magnetic resonance (MR) modalities: T2-weighted (T2-w) and dynamic contrast-enhanced (DCE) T1-w images. Two issues arise when incorporating T2-w images in a computer-aided diagnosis (CADx) system: T2-w values are position as well as sequence dependent and images can be misaligned due to patient movement during the acquisition. A method was developed that computes T2 estimates from a T2-w and proton density value and a known sequence model. A mutual information registration strategy was implemented to correct for patient movement. Global motion is modelled by an affine transformation, while local motion is described by a volume preserving non-rigid deformation based on B-splines. The additional value to the discriminating performance of a DCE T1-w-based CADx system was evaluated using bootstrapped ROC analysis. T2 estimates were successfully computed in 29 patients. T2 values were extracted and added to the CADx system from 39 malignant, 19 benign and 29 normal annotated regions. T2 values alone achieved a diagnostic accuracy of 0.85 (0.77-0.92) and showed a significantly improved discriminating performance of 0.89 (0.81-0.95), when combined with DCE T1-w features. In conclusion, the study demonstrated a simple T2 estimation method that has a diagnostic performance such that it complements a DCE T1-w-based CADx system in discriminating malignant lesions from normal and benign regions. Additionally, the T2 estimate is beneficial to visual inspection due to the removed coil profile and fixed window and level settings.

  4. Differentiating laryngeal carcinomas from precursor lesions by diffusion-weighted magnetic resonance imaging at 3.0 T: a preliminary study.

    Directory of Open Access Journals (Sweden)

    De-Sheng Shang

    Full Text Available BACKGROUND: Diffusion-weighted magnetic resonance imaging (DWI has been introduced in head and neck cancers. Due to limitations in the performance of laryngeal DWI, including the complex anatomical structure of the larynx leading to susceptibility effects, the value of DWI in differentiating benign from malignant laryngeal lesions has largely been ignored. We assessed whether a threshold for the apparent diffusion coefficient (ADC was useful in differentiating preoperative laryngeal carcinomas from precursor lesions by turbo spin-echo (TSE DWI and 3.0-T magnetic resonance. METHODS: We evaluated DWI and the ADC value in 33 pathologically proven laryngeal carcinomas and 17 precancerous lesions. RESULTS: The sensitivity, specificity, and accuracy were 81.8%, 64.7%, 76.0% by laryngostroboscopy, respectively. The sensitivity, specificity, and accuracy of conventional magnetic resonance imaging were 90.9%, 76.5%, 86.0%, respectively. Qualitative DWI analysis produced sensitivity, specificity, and accuracy values of 100.0, 88.2, and 96.0%, respectively. The ADC values were lower for patients with laryngeal carcinoma (mean 1.195±0.32×10(-3 mm(2/s versus those with laryngeal precancerous lesions (mean 1.780±0.32×10(-3 mm(2/s; P<0.001. ROC analysis showed that the area under the curve was 0.956 and the optimum threshold for the ADC was 1.455×10(-3 mm(2/s, resulting in a sensitivity of 94.1%, a specificity of 90.9%, and an accuracy of 92.9%. CONCLUSIONS: Despite some limitations, including the small number of laryngeal carcinomas included, DWI may detect changes in tumor size and shape before they are visible by laryngostroboscopy. The ADC values were lower for patients with laryngeal carcinoma than for those with laryngeal precancerous lesions. The proposed cutoff for the ADC may help distinguish laryngeal carcinomas from laryngeal precancerous lesions.

  5. Dynamic T{sub 2}-mapping during magnetic resonance guided high intensity focused ultrasound ablation of bone marrow

    Energy Technology Data Exchange (ETDEWEB)

    Waspe, Adam C.; Looi, Thomas; Mougenot, Charles; Amaral, Joao; Temple, Michael; Sivaloganathan, Siv; Drake, James M. [Centre for Image Guided Innovation and Therapeutic Intervention, The Hospital for Sick Children, Toronto, ON, M5G 1X8 (Canada); Philips Healthcare Canada, Markham, ON, L6C 2S3 (Canada); Centre for Image Guided Innovation and Therapeutic Intervention, The Hospital for Sick Children, Toronto, ON, M5G 1X8 (Canada); Department of Applied Mathematics, University of Waterloo, Waterloo, ON, N2L 3G1 (Canada); Centre for Image Guided Innovation and Therapeutic Intervention, The Hospital for Sick Children, Toronto, ON, M5G 1X8 (Canada)

    2012-11-28

    Focal bone tumor treatments include amputation, limb-sparing surgical excision with bone reconstruction, and high-dose external-beam radiation therapy. Magnetic resonance guided high intensity focused ultrasound (MR-HIFU) is an effective non-invasive thermotherapy for palliative management of bone metastases pain. MR thermometry (MRT) measures the proton resonance frequency shift (PRFS) of water molecules and produces accurate (<1 Degree-Sign C) and dynamic (<5s) thermal maps in soft tissues. PRFS-MRT is ineffective in fatty tissues such as yellow bone marrow and, since accurate temperature measurements are required in the bone to ensure adequate thermal dose, MR-HIFU is not indicated for primary bone tumor treatments. Magnetic relaxation times are sensitive to lipid temperature and we hypothesize that bone marrow temperature can be determined accurately by measuring changes in T{sub 2}, since T{sub 2} increases linearly in fat during heating. T{sub 2}-mapping using dual echo times during a dynamic turbo spin-echo pulse sequence enabled rapid measurement of T{sub 2}. Calibration of T{sub 2}-based thermal maps involved heating the marrow in a bovine femur and simultaneously measuring T{sub 2} and temperature with a thermocouple. A positive T{sub 2} temperature dependence in bone marrow of 20 ms/ Degree-Sign C was observed. Dynamic T{sub 2}-mapping should enable accurate temperature monitoring during MR-HIFU treatment of bone marrow and shows promise for improving the safety and reducing the invasiveness of pediatric bone tumor treatments.

  6. Type Inference of Turbo Pascal

    DEFF Research Database (Denmark)

    Hougaard, Ole Ildsgaard; Schwartzbach, Michael I; Askari, Hosein

    1995-01-01

    of Turbo Pascal. It has the form of a preprocessor that analyzes programs in which the type annotations are only partial or even absent. The resulting program has full type annotations, will be accepted by the standard Turbo Pascal compiler, and has polymorphic use of procedures resolved by means of code...

  7. Evaluation of the SLAP lesion using a low-field (0.2T) magnetic resonance system

    International Nuclear Information System (INIS)

    Cho, Yong Soo; Back, Chang Hee; Lee, Kyung Rae; Shin, Yun Hack

    2007-01-01

    To evaluate the diagnostic capabilities of the low-field (0.2T) magnetic resonance (MR) system in the detection of the superior labrum anterior to posterior (SLAP) lesion. One hundred fifty patients underwent magnetic resonance imaging of the shoulder over a 7-month period. Forty-six patients underwent arthroscopic surgery, and the surgical results were correlated with the findings of the MR imaging. Arthroscopic procedures were performed within a mean of 8 days after MR imaging. MR imaging of the shoulder was conducted as follows: shoulder coil; T1-weighted spin echo, coronal-oblique images; T2-weighted gradient echo, coronal-oblique and axial images; and T2-weighted spin echo, coronal oblique and sagittal-oblique images. Prospectively, one radiologist interpreted the MR images. The results of surgery were as follow: SLAP II in 26 shoulders, SLAP III in 1 shoulder, SLAP IV in 1 shoulder, normal labrum in 6 shoulder. For SLAP lesions with a higher grade than type 2, the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of the low-field MRI were 85.7%, 55.5%. 75%, 71%, and 74%, respectively. There was relatively good agreement for the comparison of the MR results obtained using a low-field MR system with the surgical findings for identifying SLAP lesions

  8. MR findings in cases of suspected impacted fracture of the femoral neck

    International Nuclear Information System (INIS)

    Stiris, M.G.; Lilleaas, F.G.

    1997-01-01

    Purpose: To evaluate MR imaging of the hip in patients with a clinically suspected impacted fracture of the femoral neck in cases where conventional plain films show negative or equivocal findings. Material and Methods: Twenty-seven such patients were prospectively examined by MR imaging with a 1.0 T unit, within 24 hours of admittance to hospital. A coronal T1-weighted turbo spin-echo sequence (n=27), and a coronal STIR sequence (n=25) or a coronal T2-weighted turbo spin-echo fast saturation sequence (n=2) were used. The evaluations were made by 2 radiologists with experience in musculoskeletal radiology. Results: There were 6 patients with a petrochanteric fracture, 2 without and 4 with slight displacement. Five patients had an impacted fracture of the femoral neck, and 3 had a fracture of the superior pubic bone. Of 2 patients with advanced arthrosis, i had an impacted femoral neck fracture and the other a nondisplaced intertrochanteric fracture. There was 1 patient who had sustained a nondisplaced acetabular fracture with increased joint fluid and muscle contusions. Three patients had muscle contusions only. Two patients had bone marrow contusions only, while 2 others with advanced coxarthrosis had increased joint fluid only. Three patients showed normal findings. Our findings led to emergency surgery in 13 cases, and conservative measures directed to the specific MR findings in 14 patients. Conclusion: MR imaging should be the first modality of choice in examining patients with a clinically suspected impacted fracture of the femoral neck where conventional films show negative or equivocal findings. (orig.)

  9. MR findings in cases of suspected impacted fracture of the femoral neck

    Energy Technology Data Exchange (ETDEWEB)

    Stiris, M.G.; Lilleaas, F.G. [Aker Hospital, Oslo (Norway). Dept. of Diagnostic Radiology

    1997-09-01

    Purpose: To evaluate MR imaging of the hip in patients with a clinically suspected impacted fracture of the femoral neck in cases where conventional plain films show negative or equivocal findings. Material and Methods: Twenty-seven such patients were prospectively examined by MR imaging with a 1.0 T unit, within 24 hours of admittance to hospital. A coronal T1-weighted turbo spin-echo sequence (n=27), and a coronal STIR sequence (n=25) or a coronal T2-weighted turbo spin-echo fast saturation sequence (n=2) were used. The evaluations were made by 2 radiologists with experience in musculoskeletal radiology. Results: There were 6 patients with a petrochanteric fracture, 2 without and 4 with slight displacement. Five patients had an impacted fracture of the femoral neck, and 3 had a fracture of the superior pubic bone. Of 2 patients with advanced arthrosis, i had an impacted femoral neck fracture and the other a nondisplaced intertrochanteric fracture. There was 1 patient who had sustained a nondisplaced acetabular fracture with increased joint fluid and muscle contusions. Three patients had muscle contusions only. Two patients had bone marrow contusions only, while 2 others with advanced coxarthrosis had increased joint fluid only. Three patients showed normal findings. Our findings led to emergency surgery in 13 cases, and conservative measures directed to the specific MR findings in 14 patients. Conclusion: MR imaging should be the first modality of choice in examining patients with a clinically suspected impacted fracture of the femoral neck where conventional films show negative or equivocal findings. (orig.).

  10. CISS MR imaging findings of epidermoid tumor : comparison with spin-echo images

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Woo; Kim, Hak Jin; Choi, Sang Yoel; Heo, Jin Sam; Jung, Hoon Sik; Lee, Suck Hong; Kim, Byung Soo [Pusan National Univ. College of Medicine, Pusan (Korea, Republic of); Lee, Jong Wha [Ulsan Univ. Hospital, Ulsan (Korea, Republic of)

    1999-03-01

    To evaluate CISS MR imaging findings of epidermoid tumor in comparison with conventional spin-echo images. We studied 6 cases of epidermoid tumor in the subarachnoid space. We used a 1.5T MR unit to obtain CISS images(TR/TE/FA ; 12.3msec/5.9 msec/700) and T1- and T2- weighted spin-echo images. CISS MR imaging findings were evaluated with respect to tumor's signal intensity , contour, and relation with adjacent structures. Conspicuity of the tumor was compared between CISS and spin-echo images. A quantitative analysis was performed by measuring tumor to CSF contrast. In qualitative analysis, three radiologists independently compared CISS image and conventional spin-echo images for visibility of the tumor and graded them into three categories( poor, good, and excellent). Epidermoid tumors were located in the cerebellopontine angle in 4 cases, the prepontine cisstern in 1 case, and the cerebellopontine angle-prepontine cistern in 1 case. The tumors were hyperintense relative to brain parenchyma and hypointense relative to CSF on CISS images, were lobulated, encased adjacent cranial nerve and vessels, and invaginated into brain parenchyma. In qualitative analysis, CISS images showed clear demarcation between tumor and CSF, exact tumor extension, and tumor's relation with cranial nerves and vessels better than conventional spin-echo images. In quantitative analysis, the mean contrast values of tumor to CSF on T1-, T2-weighted images, and CISS images were 0.12, 0.06, and 0.52, respectively. The contrast value for CISS images was significantly higher than that for T1-and T2-weighted images(p<0.05). Epidermoid tumors in the subarachnoid space are better demonstrated on CISS images than on conventional spin-echo images. This special MR sequence can be added as a routine protocol in the diagnosis of subarachnoid epidermoid tumor.

  11. Magnetic properties of the spin-density wave in (TMTSF)2X and (TMTTF)2Br

    International Nuclear Information System (INIS)

    Matsunaga, N.; Hosokawa, Y.; Iwasaki, H.; Nomura, K.; Nakamura, T.; Takahashi, T.; Saito, G.

    1999-01-01

    Magnetic properties of the spin density wave (SDW) phase in (TMTSF) 2 X (X=AsF 6 , PF 6 ) and (TMTTF) 2 Br were investigated through analyses of 1 H-NMR and static magnetization measurements. A divergent peak was observed, at the temperature T * well below the SDW transition temperature, in the 1 H spin-lattice relaxation rate in the incommensurate SDW phase of (TMTSF) 2 X. A decrease of the differential magnetic susceptibility of (TMTSF) 2 X with the field parallel to the a-axis was observed around T * . This anomaly indicates a difference of the spin canting above and below T * which divides the SDW phase. In the measurements of magnetic susceptibility on the commensurate SDW phase of (TMTTF) 2 Br, a large decrease of the spin susceptibility was observed above T SDW and non-activated type behavior in the b'-axis susceptibility is observed below the spin-flop field at low temperature. The data are discussed on the basis of commensurability. (orig.)

  12. Drude weight and optical conductivity of a two-dimensional heavy-hole gas with k-cubic spin-orbit interactions

    Energy Technology Data Exchange (ETDEWEB)

    Mawrie, Alestin; Ghosh, Tarun Kanti [Department of Physics, Indian Institute of Technology-Kanpur, Kanpur 208 016 (India)

    2016-01-28

    We present a detailed theoretical study on zero-frequency Drude weight and optical conductivity of a two-dimensional heavy-hole gas (2DHG) with k-cubic Rashba and Dresselhaus spin-orbit interactions. The presence of k-cubic spin-orbit couplings strongly modifies the Drude weight in comparison to the electron gas with k-linear spin-orbit couplings. For large hole density and strong k-cubic spin-orbit couplings, the density dependence of Drude weight deviates from the linear behavior. We establish a relation between optical conductivity and the Berry connection. Unlike two-dimensional electron gas with k-linear spin-orbit couplings, we explicitly show that the optical conductivity does not vanish even for equal strength of the two spin-orbit couplings. We attribute this fact to the non-zero Berry phase for equal strength of k-cubic spin-orbit couplings. The least photon energy needed to set in the optical transition in hole gas is one order of magnitude smaller than that of electron gas. Types of two van Hove singularities appear in the optical spectrum are also discussed.

  13. MRI of intracerebral haematoma at low field (0.15T) using T2 dependent partial saturation sequences

    International Nuclear Information System (INIS)

    Bydder, G.M.; Pennock, J.M.; Porteous, R.; Dubowitz, L.M.S.; Gadian, D.G.; Young, I.R.

    1988-01-01

    Results of MRI at 0.15T in twelve successive patients with intracerebral haematoma are reviewed. Using T 2 weighted spin echo (SE) and partial saturation (PS without a refocussing 180 0 pulse) sequences, low intensity areas were seen in eleven of the twelve cases. These included central regions (three cases), a peripheral rim (seven cases) and more diffuse patterns involving the brainstem and cerebral hemispheres (two cases). One case initially displayed a peripheral rim and later a central low intensity region. Central low intensity regions were seen in acute, subacute, and chronic cases. Follow up in five cases displayed an increase in signal within the haematoma in three cases and a decrease in signal intensity in two cases. Low signal intensity areas can be seen within and around intracerebral haematomas imaged with T 2 weighted sequences at low field strength. (orig.)

  14. Evaluation of renal function with dynamic MRI-T2-weighted gradient echo technique

    International Nuclear Information System (INIS)

    Kato, Katsuya

    1995-01-01

    To evaluate the usefulness of dynamic MRI of kidneys in healthy volunteers and patients with different 24-hour creatinine clearance (Ccr) levels, a dynamic study that employed the T2 weighted gradient echo technique (FLASH: TR/TE=34/25 msec, flip angle= 20 degrees) with single images during breathhold was performed on 10 healthy volunteers and 35 patients, all examined for the Ccr and suspected of having renal parenchymal disease after a phantom study. T1-weighted and dynamic MR imagings were obtained with a 1.5T imager. I analyzed the time-intensity curve of renal cortex and medulla, and defined a cortex decreased ratio (CDR) and medulla decreased ratio (MDR) in comparison with the Ccr. The cortico-medullary difference ratio (CMDR) of T1WI was also compared with the Ccr. The parameters of the T2 dynamic MRI study (CDR, MDR) better correlated with the Ccr than CMDR. Renal function can be quantitatively evaluated with the T2 dynamic MRI and there is a possibility that we can qualitatively evaluate the renal dysfunction and estimate its cause. (author)

  15. Suppression of spin fluctuations in TiBe2 by high magnetic fields

    International Nuclear Information System (INIS)

    Stewart, G.R.; Smith, J.L.; Brandt, B.L.

    1982-01-01

    Measurement of the low-temperature specific heat of a well-characterized 15.6-mg sample of TiBe 2 was performed in magnetic fields of 0, 6.5, 11.4, 14.2, and 17.0 T. The results indicate a striking depression of the spin-fluctuation-caused upturn with increasing field in the lower-temperature specific heat and very little change at higher temperatures where the spin fluctuations are less predominant. A field for full suppression of the spin fluctuations is extrapolated to be above about 25 T. The field at which the onset of spin-fluctuation depression occurs is 5.2 +- 0.3 T, suggesting that the previously observed anomalies in the susceptibility and differential susceptibility of TiBe 2 at 5.5 T are connected to the onset of the depression of spin fluctuations. Furthermore, this onset of spin-fluctuation depression at 5.2 +- 0.3 T coupled with the extrapolation to full suppression above 25 T serves to unify the interpretations of previous data on TiBe 2 by Wohlfarth, by Acker et al., and by van Deursen et al. which were previously thought to be in contradiction

  16. Fat-suppressed T2-weighted MRI appearance of subchondral insufficiency fracture of the femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Sonoda, Kazuhiko; Yamamoto, Takuaki; Motomura, Goro; Karasuyama, Kazuyuki; Kubo, Yusuke; Iwamoto, Yukihide [Kyushu University, Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Higashi-ku, Fukuoka (Japan)

    2016-11-15

    Our aims were to investigate the imaging appearance of subchondral insufficiency fracture (SIF) of the femoral head based on fat-suppressed T2-weighted MRI, and evaluate its correlation with the clinical outcomes following conservative treatment. We retrospectively evaluated 40 hips in 37 patients with SIF of the femoral head (12 males and 25 females; mean age 55.8 years, range 22-78 years). MRI examinations were performed within 3 months after the onset of hip pain. Using fat-suppressed T2-weighted imaging, we evaluated the hips for the intensity of the subchondral bone (corresponding to the area superior to the low intensity band on T1-weighted images) as well as bone marrow edema, joint effusion, and presence of the band lesion. We then correlated the intensity of the subchondral bone with clinical outcomes. The hips were classified into three types based on subchondral intensity on fat-suppressed T2-weighted images: type 1 (21 hips) showed high intensity, type 2 (eight hips) showed heterogeneous intensity, and type 3 (11 hips) showed low intensity. The mean period between pain onset and MRI examination was significantly longer for type 2 hips than for type 1. Healing rates were 86 % for type 1, 75 % for type 2, and 18 % for type 3. SIF cases were classified into three types based on subchondral intensity on fat-suppressed T2-weighted imaging performed within 3 months after pain onset. Type 3 SIF tended to be intractable to conservative treatment compared to type 1 and type 2. (orig.)

  17. T2 Mapping of the Sacroiliac Joints With 3-T MRI: A Preliminary Study.

    Science.gov (United States)

    Lefebvre, Guillaume; Bergère, Antonin; Rafei, Mazen El; Duhamel, Alain; Teixeira, Pedro; Cotten, Anne

    2017-08-01

    The objective of this study was to assess the feasibility of T2 relaxation time measurements of the sacroiliac joints. The sacroiliac joints of 40 patients were imaged by 3-T MRI using an oblique axial multislice multiecho spin-echo T2-weighted sequence. Manual plotting and automatic subdivision of ROIs allowed us to obtain T2 values for up to 48 different areas per patient (posterior and anterior parts, sacral, intermediate, and iliac parts). Intraand interobserver reproducibility of T2 values were calculated after independent assessment by two musculoskeletal radiologists. A total of 1656 measurement sites could be analyzed. Mean (± SD) T2 values were 40.6 ± 6.7 ms and 41.2 ± 6.3 ms for observer 1 and 39.9 ± 6.6 ms for observer 2. The intraobserver intraclass correlation coefficient was 0.72 (95% CI, 0.70-0.74), and the interobserver intraclass correlation coefficient was 0.71 (95% CI, 0.68-0.72). Our study shows the feasibility of T2 relaxation time measurements at the sacroiliac joints.

  18. Optimisation of T2*-weighted MRI for the detection of small veins in multiple sclerosis at 3 T and 7 T

    International Nuclear Information System (INIS)

    Dixon, Jennifer Elizabeth; Simpson, Ashley; Mistry, Niraj; Evangelou, Nikos; Morris, Peter Gordon

    2013-01-01

    T 2 * -weighted magnetic resonance imaging at 7 T has recently been shown to allow differentiation between white-matter multiple sclerosis lesions and asymptomatic white-matter lesions, by the presence or absence of a detectable central blood vessel. The aim of the present work is to improve the technique by increasing the sensitivity to veins at both 3 T and 7 T, and to assess the benefit of ultra-high-field imaging. Signal-to-noise ratio (SNR) measurements and simulations are used to compare the sensitivity of magnitude T 2 * -weighted and susceptibility-weighted images for the detection of small veins (<1 pixel in diameter), both with and without the use of gadolinium. The simulations are used to predict the optimal scanning parameters in order to increase the sensitivity to these veins at both field strengths, and to reduce the inherent dependence on vessel orientation. The sensitivities of the sequences at both field strengths are compared, theoretically and experimentally, in order to quantify the benefit of imaging at ultra-high-field. Subjects with multiple sclerosis (MS) are scanned at both field strengths, using the optimised sequence parameters, as well as those used in previously published work, and the optimisation is shown to improve the detection of veins within lesions

  19. Visual analysis of serial T2-weighted MRI in multiple sclerosis: intra- and interobserver reproducibility

    International Nuclear Information System (INIS)

    Molyneux, P.D.; Miller, D.H.; Filippi, M.; Yousry, T.A.; Radue, E.W.; Ader, H.J.; Barkhof, F.

    1999-01-01

    We evaluated the effect of consensus formation and training on the agreement between observers in scoring the number of new and enlarging multiple sclerosis (MS) lesions on serial T2-weighted MRI studies. The baseline and month 9 MRI studies of 16 patients with a range of MRI activity were used (dual-echo conventional spin-echo sequence, TR 2000, TE 34 and 90 ms, 5 mm contiguous slices, in-plane resolution 1 mm). First, the serial studies were visually analysed for the presence of new and enlarging lesions, on two occasions, by five experienced observers, without adopting any consensus strategy and in isolation. Next, the observers met to identify the common sources of inconsistencies in reporting between observers and formulate consensus rules. Finally, a further independent reading session was performed on the same MRI dataset, this time applying the consensus rules. Agreement between observers was assessed using kappa scores. Without the consensus rules, interobserver kappa scores for the first and second reading sessions for new lesions were only 0.51 and 0.39 respectively; agreement for enlarging lesions was even worse. The mean intraobserver kappa score for new lesions was higher at 0.72, reflecting the fact that the observers were consistently applying their individual assessment strategies. Application of the consensus rules did not lead to a significant improvement in inter observer kappas; the kappa scores adopting the guidelines were 0.46 and 0.21 for new and enlarging lesions respectively. Consensus guidelines thus did not improve the reproducibility of visual analysis of serial T2-weighted MRI, and the level of agreement between observers remained only moderate. Suboptimal repositioning is likely to be a major source of residual variability and this suggests a future role for image registration strategies; until then, a single observer, or pair of observers working in consensus, should be used in MS studies. (orig.)

  20. Fast spin-echo MR imaging of the eye

    International Nuclear Information System (INIS)

    Hosten, N.; Lemke, A.J.; Bornfeld, N.; Wassmuth, R.; Schweiger, U.; Terstegge, K.; Felix, R.

    1996-01-01

    Magnetic resonance imaging of the eye usually includes T2-weighted images both for screening purposes and for characterization of melanoma. Conventional T2-weighted spin-echo (SE) imaging suffers both from long acquisition times and incomplete recovery of the virteous' signal. A fast SE sequence was therefore compared prospectively with conventional sequences in 29 consecutive patients with lesions of the eye. Fast SE images delineated melanoma and other lesions of the eye from vitreous better than conventional T2-weighted images. Image quality and lesion conspicuity were improved on the fast sequence. Whereas melanoma appeared hypointense to vitreous on both types of images, subretinal effusion was hypointense on fast images and hyperintense on conventional T2-weighted images. Ghosting of the globe, which, however, did not decrease diagnostic value, was more pronounced on fast images. Conventional T2-weighted images may be replaced by fast SE images in MR studies of the eye with a gain in lesion conspicuity and significant time saving. (orig.)

  1. Clinical Study White Matter Atrophy in Patients with Mesial Temporal Lobe Epilepsy: Voxel-Based Morphometry Analysis of T1- and T2-Weighted MR Images

    International Nuclear Information System (INIS)

    Braga, B.; Yasuda, C.L.; Cendes, F.

    2012-01-01

    Introduction. Mesial temporal lobe epilepsy (MTLE) associated with hippocampal sclerosis is highly refractory to clinical treatment. MRI voxel-based morphometry (VBM) of T1-weighted images has revealed a widespread pattern of gray matter (GM) and white matter (WM) atrophy in MTLE. Few studies have investigated the role of T2-weighted images in revealing WM atrophy using VBM. Objectives. To compare the results of WM atrophy between T1- and T2-weighted images through VBM. Methods. We selected 28 patients with left and 27 with right MTLE and 60 normal controls. We analyzed T1- and T2- weighted images with SPM8, using VBM/DARTEL algorithm to extract maps of GM and WM. The second level of SPM was used to investigate areas of WM atrophy among groups. Results. Both acquisitions showed bilateral widespread WM atrophy. T1-weighted images showed higher sensibility to detect areas of WM atrophy in both groups of MTLE. T2-weighted images also showed areas of WM atrophy in a more restricted pattern, but still bilateral and with a large area of superposition with T1-weighted images. Conclusions. In MTLE, T1-weighted images are more sensitive to detect subtle WM abnormalities using VBM, compared to T2 images, although both present a good superposition of statistical maps. 1. Introduction The mesial temporal lobe epilepsy (MTLE) is highly refractory to pharmacological treatment [1], and it is the main group of epilepsy referred to the tertiary care hospitals for surgical treatment [2]. MTLE shows a good surgical prognosis, with satisfactory seizures control in 60-80% of the patients [3]. In approximately 65%

  2. Relationship between levels of serum creatinine and perirenal hyperintensity on heavily T2-weighted MR images

    Energy Technology Data Exchange (ETDEWEB)

    Erden, Ayse, E-mail: ayse.erden@medicine.ankara.edu.tr [Ankara University, School of Medicine, Department of Radiology, Talatpasa Bulvari, Sihhiye, 06100 Ankara (Turkey); Sahin, Burcu Savran, E-mail: bsavrans@hotmail.com [Ankara University, School of Medicine, Department of Radiology, Talatpasa Bulvari, Sihhiye, 06100 Ankara (Turkey); Orgodol, Horolsuren, E-mail: hoogii99@yahoo.com [Ankara University, School of Medicine, Department of Radiology, Talatpasa Bulvari, Sihhiye, 06100 Ankara (Turkey); Erden, Ilhan, E-mail: erden@medicine.ankara.edu.tr [Ankara University, School of Medicine, Department of Radiology, Talatpasa Bulvari, Sihhiye, 06100 Ankara (Turkey); Biyikli, Zeynep, E-mail: zeynep.biyikli@gmail.com [Ankara University, School of Medicine, Department of Biostatistics, Talatpasa Bulvari, Sihhiye, 06100 Ankara (Turkey)

    2011-11-15

    Objective: To determine the frequency of perirenal hyperintensity on heavily T2-weighted images and to evaluate its relationship with serum creatinine levels. Subjects and methods: Axial and coronal single-shot fast spin-echo images which have been originally obtained for MR cholangiopancreatography in 150 subjects were examined by two observers individually for the presence of perirenal hyperintensity. The morphologic properties of perirenal hyperintensity (peripheral rim-like, discontinuous, polar) were recorded. Chi square test was used to test whether the frequencies of bilateral perirenal hyperintensity differ significantly in subjects with high serum creatinine levels and those with normal creatinine levels. This test was also used to compare the frequencies of perirenal hyperintensity in patients with and without renal cysts and in patients with and without corticomedullary differentiation. A p value of less than 0.05 was considered to be statistically significant. Results: The perirenal hyperintensity was identified in 40 of 150 cases (26.6%) on heavily T2-weighted image. Serum creatinine levels were high in 18 of 150 cases (12%). The perirenal hyperintensity was present in 11 of 18 subjects (61%) with high serum creatinine levels and 26 of 132 subjects (19.7%) with normal creatinine levels. The difference of rates in two groups was statistically significant. Odds ratio was 6407 (95% confidence interval 2264-18,129). The frequency of perirenal hyperintensity was also significantly higher in subjects with renal cyst or cysts in whom serum creatinine levels were normal (p < 0.05) (37.5% vs. 11.8%). Conclusion: Perirenal hyperintensities are more frequent in patients with high serum creatinine levels. They are also more common in patients with simple renal cysts.

  3. Relationship between levels of serum creatinine and perirenal hyperintensity on heavily T2-weighted MR images

    International Nuclear Information System (INIS)

    Erden, Ayse; Sahin, Burcu Savran; Orgodol, Horolsuren; Erden, Ilhan; Biyikli, Zeynep

    2011-01-01

    Objective: To determine the frequency of perirenal hyperintensity on heavily T2-weighted images and to evaluate its relationship with serum creatinine levels. Subjects and methods: Axial and coronal single-shot fast spin-echo images which have been originally obtained for MR cholangiopancreatography in 150 subjects were examined by two observers individually for the presence of perirenal hyperintensity. The morphologic properties of perirenal hyperintensity (peripheral rim-like, discontinuous, polar) were recorded. Chi square test was used to test whether the frequencies of bilateral perirenal hyperintensity differ significantly in subjects with high serum creatinine levels and those with normal creatinine levels. This test was also used to compare the frequencies of perirenal hyperintensity in patients with and without renal cysts and in patients with and without corticomedullary differentiation. A p value of less than 0.05 was considered to be statistically significant. Results: The perirenal hyperintensity was identified in 40 of 150 cases (26.6%) on heavily T2-weighted image. Serum creatinine levels were high in 18 of 150 cases (12%). The perirenal hyperintensity was present in 11 of 18 subjects (61%) with high serum creatinine levels and 26 of 132 subjects (19.7%) with normal creatinine levels. The difference of rates in two groups was statistically significant. Odds ratio was 6407 (95% confidence interval 2264-18,129). The frequency of perirenal hyperintensity was also significantly higher in subjects with renal cyst or cysts in whom serum creatinine levels were normal (p < 0.05) (37.5% vs. 11.8%). Conclusion: Perirenal hyperintensities are more frequent in patients with high serum creatinine levels. They are also more common in patients with simple renal cysts.

  4. Kinetics of a mixed spin-1/2 and spin-3/2 Ising ferrimagnetic model

    International Nuclear Information System (INIS)

    Deviren, Bayram; Keskin, Mustafa; Canko, Osman

    2009-01-01

    We present a study, within a mean-field approach, of the kinetics of a mixed ferrimagnetic model on a square lattice in which two interpenetrating square sublattices have spins that can take two values, σ=±1/2 , alternated with spins that can take the four values, S=±3/2 ,±1/2 . We use the Glauber-type stochastic dynamics to describe the time evolution of the system with a crystal-field interaction in the presence of a time-dependent oscillating external magnetic field. The nature (continuous and discontinuous) of transition is characterized by studying the thermal behaviors of average order parameters in a period. The dynamic phase transition points are obtained and the phase diagrams are presented in the reduced magnetic field amplitude (h) and reduced temperature (T) plane, and in the reduced temperature and interaction parameter planes, namely in the (h, T) and (d, T) planes, d is the reduced crystal-field interaction. The phase diagrams always exhibit a tricritical point in (h, T) plane, but do not exhibit in the (d, T) plane for low values of h. The dynamic multicritical point or dynamic critical end point exist in the (d, T) plane for low values of h. Moreover, phase diagrams contain paramagnetic (p), ferromagnetic (f), ferrimagnetic (i) phases, two coexistence or mixed phase regions, (f+p) and (i+p), that strongly depend on interaction parameters

  5. Kinetics of a mixed spin-1/2 and spin-3/2 Ising ferrimagnetic model

    Energy Technology Data Exchange (ETDEWEB)

    Deviren, Bayram [Institute of Science, Erciyes University, 38039 Kayseri (Turkey); Keskin, Mustafa [Department of Physics, Erciyes University, 38039 Kayseri (Turkey)], E-mail: keskin@erciyes.edu.tr; Canko, Osman [Department of Physics, Erciyes University, 38039 Kayseri (Turkey)

    2009-03-15

    We present a study, within a mean-field approach, of the kinetics of a mixed ferrimagnetic model on a square lattice in which two interpenetrating square sublattices have spins that can take two values, {sigma}={+-}1/2 , alternated with spins that can take the four values, S={+-}3/2 ,{+-}1/2 . We use the Glauber-type stochastic dynamics to describe the time evolution of the system with a crystal-field interaction in the presence of a time-dependent oscillating external magnetic field. The nature (continuous and discontinuous) of transition is characterized by studying the thermal behaviors of average order parameters in a period. The dynamic phase transition points are obtained and the phase diagrams are presented in the reduced magnetic field amplitude (h) and reduced temperature (T) plane, and in the reduced temperature and interaction parameter planes, namely in the (h, T) and (d, T) planes, d is the reduced crystal-field interaction. The phase diagrams always exhibit a tricritical point in (h, T) plane, but do not exhibit in the (d, T) plane for low values of h. The dynamic multicritical point or dynamic critical end point exist in the (d, T) plane for low values of h. Moreover, phase diagrams contain paramagnetic (p), ferromagnetic (f), ferrimagnetic (i) phases, two coexistence or mixed phase regions, (f+p) and (i+p), that strongly depend on interaction parameters.

  6. Population structure and accompanying biota of the snail Turbo (Callopoma funiculosus (Gastropoda: Turbinidae, on Socorro Island, Revillagigedo Archipelago, Mexico

    Directory of Open Access Journals (Sweden)

    Oscar E Holguin Quiñones

    2006-12-01

    Full Text Available The porcelain snail, Turbo funiculosus, is a potential fishery resource that almost has not been studied or used commercially. In March of 1992, we sampled T. funiculosus in Bahía Binners and Bahía Blanca, Socorro Island, Revillagigedo Archipelago, using 25 m² quadrants. We found that total length varies between 3.0 and 85 mm, proportional weight between 3.0 and 228 g, and density between 6.21 and 9.87 ind/m². The largest organisms (over 50 mm contain 30.6 % of soft parts. Porcelain snail populations remain unexploited on Revillagedo Archipelago and could be a potential resource under an adequate management strategy. Rev. Biol. Trop. 54 (4: 1079-1084. Epub 2006 Dec. 15.El caracol porcelana, Turbo funiculosus, es un recurso pesquero potencial que casi no ha sido estudiado ni se ha utilizado comercialmente. En marzo de 1992, se realizó un muestreo de T. funiculosus en Bahía Binners y Bahía Blanca, isla Socorro, archipiélago Revillagigedo, empleando cuadrantes de 25 m2. Se encontraron variaciones en la longitud total entre 3.0 y 85 mm, el peso proporcional entre 3.0 y 228 g, y la densidad entre 6.21 y 9.87 ind/m2. Los organismos de mayor tamaño (más de 50 mm contienen 30.6 % de partes suaves. Las poblaciones del caracol porcelana siguen siendo inexplotadas en el archipiélago Revillagedo y podrían ser un recurso potencial de la industria pesquera bajo un adecuado plan de manejo.

  7. TurboSP and the Topological Trigger

    CERN Document Server

    Belavin, Vladislav

    2016-01-01

    TurboSP was originally proposed as an alternative to Full stream in LHCb data flow. TurboSP is a data flow strategy which not only selects events that should be preserved, like in Full stream, but also provides selective persistence. This is achieved by saving candidates and subset of the reconstruction. During this summer project we investigated the physics viability of using TurboSP with the topological lines and found out a possibility to reduce the number of kept tracks per event by two times while keeping a ratio of fully picked up interesting decay modes on $\\sim 97 \\%$ level.

  8. Thirty Minutes of Running Exercise Decreases T2 Signal Intensity but Not Thickness of the Knee Joint Cartilage: A 3.0-T Magnetic Resonance Imaging Study.

    Science.gov (United States)

    Karanfil, Yiğitcan; Babayeva, Naila; Dönmez, Gürhan; Diren, H Barış; Eryılmaz, Muzaffer; Doral, Mahmut Nedim; Korkusuz, Feza

    2018-04-01

    Objective Recent studies showed a potential of magnetic resonance imaging (MRI), which can be used as an additional tool for diagnosing cartilage degeneration in the early stage. We designed a cross-sectional study in order to evaluate knee joint cartilage adaptation to running, using 3.0-T MRI equipped with the 3-dimensional turbo spin echo (VISTA = Volume ISotropic Turbo spin echo Acquisition) software. By this thickness (mm) and signal intensity (mean pixel value) can be quantified, which could be closely related to the fluid content of the knee joint cartilage, before and after running. Methods A total of 22 males, aged 18 to 35 years, dominant (right) and nondominant (left) knees were assessed before and after 30 minutes of running. Cartilage thickness and signal intensity of surfaces of the patella, medial and lateral femoral and tibial condyles were measured. Results Cartilage thickness of the lateral condyle decreased at the dominant knee, while it increased at the medial tibial plateau. Signal intensity decreased at all locations, except the lateral patella in both knees. The most obvious decrease in signal intensity (10.6%) was at the medial tibial plateau from 949.8 to 849.0 of the dominant knee. Conclusion There was an increase in thickness measurements and decrease in signal intensity in medial tibial plateau of the dominant knee after 30 minutes of running. This outcome could be related to fluid outflow from the tissue. Greater reductions in the medial tibial plateau cartilage indicate greater load sharing by these areas of the joint during a 30-minute running.

  9. The Case for Distributed Engine Control in Turbo-Shaft Engine Systems

    Science.gov (United States)

    Culley, Dennis E.; Paluszewski, Paul J.; Storey, William; Smith, Bert J.

    2009-01-01

    The turbo-shaft engine is an important propulsion system used to power vehicles on land, sea, and in the air. As the power plant for many high performance helicopters, the characteristics of the engine and control are critical to proper vehicle operation as well as being the main determinant to overall vehicle performance. When applied to vertical flight, important distinctions exist in the turbo-shaft engine control system due to the high degree of dynamic coupling between the engine and airframe and the affect on vehicle handling characteristics. In this study, the impact of engine control system architecture is explored relative to engine performance, weight, reliability, safety, and overall cost. Comparison of the impact of architecture on these metrics is investigated as the control system is modified from a legacy centralized structure to a more distributed configuration. A composite strawman system which is typical of turbo-shaft engines in the 1000 to 2000 hp class is described and used for comparison. The overall benefits of these changes to control system architecture are assessed. The availability of supporting technologies to achieve this evolution is also discussed.

  10. Evaluation of neonatal brain myelination using the T1- and T2-weighted MRI ratio.

    Science.gov (United States)

    Soun, Jennifer E; Liu, Michael Z; Cauley, Keith A; Grinband, Jack

    2017-09-01

    To validate the T1- and T2-weighted (T1w/T2w) MRI ratio technique in evaluating myelin in the neonatal brain. T1w and T2w MR images of 10 term neonates with normal-appearing brain parenchyma were obtained from a single 1.5 Tesla MRI and retrospectively analyzed. T1w/T2w ratio images were created with a postprocessing pipeline and qualitatively compared with standard clinical sequences (T1w, T2w, and apparent diffusion coefficient [ADC]). Quantitative assessment was also performed to assess the ratio technique in detecting areas of known myelination (e.g., posterior limb of the internal capsule) and very low myelination (e.g., optic radiations) using linear regression analysis and the Michelson Contrast equation, a measure of luminance contrast intensity. The ratio image provided qualitative improvements in the ability to visualize regional variation in myelin content of neonates. Linear regression analysis demonstrated a significant inverse relationship between the ratio intensity values and ADC values in the posterior limb of the internal capsule and the optic radiations (R 2  = 0.96 and P ratio images were 1.6 times higher than T1w, 2.6 times higher than T2w, and 1.8 times higher than ADC (all P ratio improved visualization of the corticospinal tract, one of the earliest myelinated pathways. The T1w/T2w ratio accentuates contrast between myelinated and less myelinated structures and may enhance our diagnostic ability to detect myelination patterns in the neonatal brain. 2 Technical Efficacy: Stage2 J. MAGN. RESON. IMAGING 2017;46:690-696. © 2016 International Society for Magnetic Resonance in Medicine.

  11. T2-weighted MRI-derived textural features reflect prostate cancer aggressiveness: preliminary results.

    Science.gov (United States)

    Nketiah, Gabriel; Elschot, Mattijs; Kim, Eugene; Teruel, Jose R; Scheenen, Tom W; Bathen, Tone F; Selnæs, Kirsten M

    2017-07-01

    To evaluate the diagnostic relevance of T2-weighted (T2W) MRI-derived textural features relative to quantitative physiological parameters derived from diffusion-weighted (DW) and dynamic contrast-enhanced (DCE) MRI in Gleason score (GS) 3+4 and 4+3 prostate cancers. 3T multiparametric-MRI was performed on 23 prostate cancer patients prior to prostatectomy. Textural features [angular second moment (ASM), contrast, correlation, entropy], apparent diffusion coefficient (ADC), and DCE pharmacokinetic parameters (K trans and V e ) were calculated from index tumours delineated on the T2W, DW, and DCE images, respectively. The association between the textural features and prostatectomy GS and the MRI-derived parameters, and the utility of the parameters in differentiating between GS 3+4 and 4+3 prostate cancers were assessed statistically. ASM and entropy correlated significantly (p textural features correlated insignificantly with K trans and V e . GS 4+3 cancers had significantly lower ASM and higher entropy than 3+4 cancers, but insignificant differences in median ADC, K trans , and V e . The combined texture-MRI parameters yielded higher classification accuracy (91%) than the individual parameter sets. T2W MRI-derived textural features could serve as potential diagnostic markers, sensitive to the pathological differences in prostate cancers. • T2W MRI-derived textural features correlate significantly with Gleason score and ADC. • T2W MRI-derived textural features differentiate Gleason score 3+4 from 4+3 cancers. • T2W image textural features could augment tumour characterization.

  12. The value of fat-suppressed T2 or STIR sequences in distinguishing lipoma from well-differentiated liposarcoma

    Energy Technology Data Exchange (ETDEWEB)

    Galant, J. [Servicio de Radiodiagnostico, Hospital Universitario San Juan de Alicante, Ctra. Nacional 332 Alicante-Valencia s/n, 03550 San Juan de Alicante (Spain); Resonancia Magnetica del Sureste, Murcia (Spain); Marti-Bonmati, L. [Department of Radiology, Hospital Universitario Dr. Peset, Valencia (Spain); Saez, F. [Department of Radiology, Hospital Cruces de Baracaldo, Vizcaya (Spain); Soler, R. [Department of Radiology, Hospital Juan Canalejo, A Coruna (Spain); Alcala-Santaella, R. [Department of Traumatology, Hospital Universitario San Juan de Alicante, Ctra. Nacional 332 Alicante-Valencia s/n, 03550 San Juan de Alicante (Spain); Navarro, M. [Servicio de Radiodiagnostico, Hospital Universitario San Juan de Alicante, Ctra. Nacional 332 Alicante-Valencia s/n, 03550 San Juan de Alicante (Spain)

    2003-02-01

    The objective of this study was to evaluate the diagnostic value of fat-suppressed T2-weighted (FS-T2) images or short tau inversion recovery (STIR) imaging in distinguishing lipoma from lipoma-like subtype of well-differentiated liposarcoma. Spin-echo T1-weighted and STIR or fat-suppression T2-weighted sequences were performed in 60 lipomas and 32 lipoma-like well-differentiated liposarcomas, histologically proven, looking for thick septa or nodules in T1-weighted images and linear, nodular, or amorphous hyperintensities on FS-T2/STIR sequences. Fourteen lipomas (23.3%) showed thick septa and/or nodules on T1, whereas on FS-T2 or STIR sequences only seven (11.7%) displayed hyperintense nodules and/or septa. All well-differentiated liposarcomas contained these signs on FS-T2 or STIR sequences. The presence of hyperintense septa or nodules in a predominantly lipomatous tumor on FS-T2/STIR sequences helps to differentiate malignant tumors from lipomas. Employing the presence of hyperintense nodules and/or septa as criteria of malignancy specificity was 76.6% and sensitivity 100%. Overdiagnoses of well-differentiated liposarcoma can occur due to the presence of non-lipomatous areas within lipomas. (orig.)

  13. The value of fat-suppressed T2 or STIR sequences in distinguishing lipoma from well-differentiated liposarcoma

    International Nuclear Information System (INIS)

    Galant, J.; Marti-Bonmati, L.; Saez, F.; Soler, R.; Alcala-Santaella, R.; Navarro, M.

    2003-01-01

    The objective of this study was to evaluate the diagnostic value of fat-suppressed T2-weighted (FS-T2) images or short tau inversion recovery (STIR) imaging in distinguishing lipoma from lipoma-like subtype of well-differentiated liposarcoma. Spin-echo T1-weighted and STIR or fat-suppression T2-weighted sequences were performed in 60 lipomas and 32 lipoma-like well-differentiated liposarcomas, histologically proven, looking for thick septa or nodules in T1-weighted images and linear, nodular, or amorphous hyperintensities on FS-T2/STIR sequences. Fourteen lipomas (23.3%) showed thick septa and/or nodules on T1, whereas on FS-T2 or STIR sequences only seven (11.7%) displayed hyperintense nodules and/or septa. All well-differentiated liposarcomas contained these signs on FS-T2 or STIR sequences. The presence of hyperintense septa or nodules in a predominantly lipomatous tumor on FS-T2/STIR sequences helps to differentiate malignant tumors from lipomas. Employing the presence of hyperintense nodules and/or septa as criteria of malignancy specificity was 76.6% and sensitivity 100%. Overdiagnoses of well-differentiated liposarcoma can occur due to the presence of non-lipomatous areas within lipomas. (orig.)

  14. Optimization image of magnetic resonance imaging (MRI) T2 fast spin echo (FSE) with variation echo train length (ETL) on the rupture tendon achilles case

    International Nuclear Information System (INIS)

    Muzamil, Akhmad; Firmansyah, Achmad Haries

    2017-01-01

    The research was done the optimization image of Magnetic Resonance Imaging (MRI) T2 Fast Spin Echo (FSE) with variation Echo Train Length (ETL) on the Rupture Tendon Achilles case. This study aims to find the variations Echo Train Length (ETL) from the results of ankle’s MRI image and find out how the value of Echo Train Length (ETL) works on the MRI ankle to produce optimal image. In this research, the used ETL variations were 12 and 20 with the interval 2 on weighting T2 FSE sagittal. The study obtained the influence of Echo Train Length (ETL) on the quality of ankle MRI image sagittal using T2 FSE weighting and analyzed in 25 images of five patients. The data analysis has done quantitatively with the Region of Interest (ROI) directly on computer MRI image planes which conducted statistical tests Signal to Noise Ratio (SNR) and Contras to Noise Ratio (CNR). The Signal to Noise Ratio (SNR) was the highest finding on fat tissue, while the Contras to Noise Ratio (CNR) on the Tendon-Fat tissue with ETL 12 found in two patients. The statistics test showed the significant SNR value of the 0.007 (p<0.05) of Tendon tissue, 0.364 (p>0.05) of the Fat, 0.912 (p>0.05) of the Fibula, and 0.436 (p>0.05) of the Heel Bone. For the contrast to noise ratio (CNR) of the Tendon-FAT tissue was about 0.041 (p>0.05). The results of the study showed that ETL variation with T2 FSE sagittal weighting had difference at Tendon tissue and Tendon-Fat tissue for MRI imaging quality. SNR and CNR were an important aspect on imaging optimization process to give the diagnose information. (paper)

  15. Anomalous quantum critical spin dynamics in YFe2Al10

    Science.gov (United States)

    Huang, K.; Tan, C.; Zhang, J.; Ding, Z.; MacLaughlin, D. E.; Bernal, O. O.; Ho, P.-C.; Baines, C.; Wu, L. S.; Aronson, M. C.; Shu, L.

    2018-04-01

    We report results of a muon spin relaxation (μ SR ) study of YFe2Al10 , a quasi-two-dimensional (2D) nearly ferromagnetic metal in which unconventional quantum critical behavior is observed. No static Fe2 + magnetism, with or without long-range order, is found down to 19 mK. The dynamic muon spin relaxation rate λ exhibits power-law divergences in temperature and magnetic field, the latter for fields that are too weak to affect the electronic spin dynamics directly. We attribute this to the proportionality of λ (ωμ,T ) to the dynamic structure factor S (ωμ,T ) , where ωμ≈105-107s-1 is the muon Zeeman frequency. These results suggest critical divergences of S (ωμ,T ) in both temperature and frequency. Power-law scaling and a 2D dissipative quantum XY model both yield forms for S (ω ,T ) that agree with neutron scattering data (ω ≈1012s-1 ). Extrapolation to μ SR frequencies agrees semiquantitatively with the observed temperature dependence of λ (ωμ,T ) , but predicts frequency independence for ωμ≪T , in extreme disagreement with experiment. We conclude that the quantum critical spin dynamics of YFe2Al10 is not well understood at low frequencies.

  16. Quantitative analysis of MR perfusion/diffusion images in a dog model of renal artery stenosis with microsphere correlation

    International Nuclear Information System (INIS)

    Lorens, C.H.; Powers, T.A.; Holburn, G.E.; Price, R.R.

    1990-01-01

    This paper compares MR perfusion/diffusion-derived parameters with microsphere determination of asymmetry of renal perfusion in a dog model of renal artery stenosis. A left renal artery stenosis was created by placement of a silk ligature. Nb-95-labeled microspheres were injected into the left ventricle, and a reference blood sample was drawn. The dog was imaged in a 1.5-T MR imager with both spin-echo and turbo-FLASH perfusion/diffusion-sensitive pulse sequences. The kidneys were excised, weighted, divided into sections, and counted. Two dogs have been studied to date. In dog 1, left renal blood flow (RBF) was 42 mL/min/100g and right RBF was 337 mL/min/100g. In dog 2 left RBF was 444 mL/min/100g and right RBF was 608 mL/min/100g. The apparent diffusion coefficients (ADC) reflected the asymmetry of flow in dog 1 for both spin-echo and turbo-FLASH sequences (RADC/LADC = 1.7) and showed essentially equal flow in dog 2(RADC/LADC = 0.7)

  17. Turbo-generator control with variable valve actuation

    Science.gov (United States)

    Vuk, Carl T [Denver, IA

    2011-02-22

    An internal combustion engine incorporating a turbo-generator and one or more variably activated exhaust valves. The exhaust valves are adapted to variably release exhaust gases from a combustion cylinder during a combustion cycle to an exhaust system. The turbo-generator is adapted to receive exhaust gases from the exhaust system and rotationally harness energy therefrom to produce electrical power. A controller is adapted to command the exhaust valve to variably open in response to a desired output for the turbo-generator.

  18. Magnetic resonance imaging in cadaver dogs with metallic vertebral implants at 3 Tesla: evaluation of the WARP-turbo spin echo sequence.

    Science.gov (United States)

    Griffin, John F; Archambault, Nicholas S; Mankin, Joseph M; Wall, Corey R; Thompson, James A; Padua, Abraham; Purdy, David; Kerwin, Sharon C

    2013-11-15

    Laboratory investigation, ex vivo. Postoperative complications are common after spinal implantation procedures, and magnetic resonance imaging (MRI) would be the ideal modality to image these patients. Unfortunately, the implants cause artifacts that can render MRI nondiagnostic. The WARP-turbo spin echo (TSE) sequence has been developed to mitigate artifacts caused by metal. The objective of this investigation was to evaluate the performance of the WARP-TSE sequence in canine cadaver specimens after implantation with metallic vertebral implants. Magnetic field strength, implant type, and MRI acquisition technique all play a role in the severity of susceptibility artifacts. The WARP-TSE sequence uses increased bandwidth, view angle tilting, and SEMAC (slice-encoding metal artifact correction) to correct for susceptibility artifact. The WARP-TSE technique has outperformed conventional techniques in patients, after total hip arthroplasty. However, published reports of its application in subjects with vertebral column implants are lacking. Ex vivo anterior stabilization of the atlantoaxial joint was performed on 6 adult small breed (implantation with stainless steel implants. N/A.

  19. T1ρ-weighted Dynamic Glucose-enhanced MR Imaging in the Human Brain.

    Science.gov (United States)

    Paech, Daniel; Schuenke, Patrick; Koehler, Christina; Windschuh, Johannes; Mundiyanapurath, Sibu; Bickelhaupt, Sebastian; Bonekamp, David; Bäumer, Philipp; Bachert, Peter; Ladd, Mark E; Bendszus, Martin; Wick, Wolfgang; Unterberg, Andreas; Schlemmer, Heinz-Peter; Zaiss, Moritz; Radbruch, Alexander

    2017-12-01

    Purpose To evaluate the ability to detect intracerebral regions of increased glucose concentration at T1ρ-weighted dynamic glucose-enhanced (DGE) magnetic resonance (MR) imaging at 7.0 T. Materials and Methods This prospective study was approved by the institutional review board. Nine patients with newly diagnosed glioblastoma and four healthy volunteers were included in this study from October 2015 to July 2016. Adiabatically prepared chemical exchange-sensitive spin-lock imaging was performed with a 7.0-T whole-body unit with a temporal resolution of approximately 7 seconds, yielding the time-resolved DGE contrast. T1ρ-weighted DGE MR imaging was performed with injection of 100 mL of 20% d-glucose via the cubital vein. Glucose enhancement, given by the relative signal intensity change at T1ρ-weighted MR imaging (DGEρ), was quantitatively investigated in brain gray matter versus white matter of healthy volunteers and in tumor tissue versus normal-appearing white matter of patients with glioblastoma. The median signal intensities of the assessed brain regions were compared by using the Wilcoxon rank-sum test. Results In healthy volunteers, the median signal intensity in basal ganglia gray matter (DGEρ = 4.59%) was significantly increased compared with that in white matter tissue (DGEρ = 0.65%) (P = .028). In patients, the median signal intensity in the glucose-enhanced tumor region as displayed on T1ρ-weighted DGE images (DGEρ = 2.02%) was significantly higher than that in contralateral normal-appearing white matter (DGEρ = 0.08%) (P brain glucose physiology and pathophysiologically increased glucose uptake and may have the potential to provide information about glucose metabolism in tumor tissue. © RSNA, 2017 Online supplemental material is available for this article.

  20. Fat suppression at three-dimensional T1-weighted MR imaging of the hands: Dixon method versus CHESS technique.

    Science.gov (United States)

    Kirchgesner, T; Perlepe, V; Michoux, N; Larbi, A; Vande Berg, B

    2018-01-01

    To compare the effectiveness of fat suppression and the image quality of the Dixon method with those of the chemical shift-selective (CHESS) technique in hands of normal subjects at non-enhanced three-dimensional (3D) T1-weighted MR imaging. Both hands of 14 healthy volunteers were imaged with 3D fast spoiled gradient echo (FSPGR) T1-weighted Dixon, 3D FSPGR T1-weighted CHESS and 3D T1-weighted fast spin echo (FSE) CHESS sequences in a 1.5T MR scanner. Three radiologists scored the effectiveness of fat suppression in bone marrow (EFS BM ) and soft tissues (EFS ST ) in 20 joints per subject. One radiologist measured the signal-to-noise ratio (SNR) in 10 bones per subject. Statistical analysis used two-way ANOVA with random effects (PCHESS sequence and the 3D FSE T1-weighted CHESS sequence (PCHESS sequence (PCHESS sequence in the axial plane (P=0.0028). Mean SNR was statistically significantly higher for 3D FSPGR T1-weighted Dixon sequence than for 3D FSPGR T1-weighted CHESS and 3D FSE T1-weighted CHESS sequences (PCHESS technique at 3D T1-weighted MR imaging of the hands. Copyright © 2017 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  1. Joint research for innovative turbo machines in power stations

    Energy Technology Data Exchange (ETDEWEB)

    Wiedermann, Alexander [MAN Diesel und Turbo SE, Oberhausen (Germany). AG Turbo; Jeschke, Peter [RWTH, Aachen (Germany). AG Turbo; Goldschmidt, Dirk [SIEMENS AG, Muelheim a.d. Ruhr (Germany). AG Turbo

    2013-04-01

    AG Turbo, established about 25 years ago, is a platform where pre-competitive, application-oriented turbo machinery research in Germany is agreed and coordinated. Focus of the research is on turbo machines which are responsible for energy conversion in conventional fossil-fired or combined cycle power plants (CCGT), as well as compressor trains for capturing and transporting the greenhouse gas CO{sub 2}. At all stages of the technical process - from gas compression through combustion in gas turbine combustors to expansion in the turbine - innovations are needed to actually meet the targets for efficiency, reliability, as well as protection of the climate and environment. Research results achieved will be presented using selected examples and an outlook at future activities will be given.

  2. MR urography (MRU of non-dilated ureter with diuretic administration: Static fluid 2D FSE T2-weighted versus 3D gadolinium T1-weighted GE excretory MR

    Directory of Open Access Journals (Sweden)

    C. Roy

    2014-01-01

    Conclusion: T2-weighted MRU with multiple orientations and diuretic is sufficient to identify the non-dilated ureter. It offers information on ureteral peristaltism. It can be suggested that this sequence is able to detect an initial obstruction before hydronephrosis occurs.

  3. Evaluation of diffusivity in the anterior lobe of the pituitary gland: 3D turbo field echo with diffusion-sensitized driven-equilibrium preparation.

    Science.gov (United States)

    Hiwatashi, A; Yoshiura, T; Togao, O; Yamashita, K; Kikuchi, K; Kobayashi, K; Ohga, M; Sonoda, S; Honda, H; Obara, M

    2014-01-01

    3D turbo field echo with diffusion-sensitized driven-equilibrium preparation is a non-echo-planar technique for DWI, which enables high-resolution DWI without field inhomogeneity-related image distortion. The purpose of this study was to evaluate the feasibility of diffusion-sensitized driven-equilibrium turbo field echo in evaluating diffusivity in the normal pituitary gland. First, validation of diffusion-sensitized driven-equilibrium turbo field echo was attempted by comparing it with echo-planar DWI. Five healthy volunteers were imaged by using diffusion-sensitized driven-equilibrium turbo field echo and echo-planar DWI. The imaging voxel size was 1.5 × 1.5 × 1.5 mm(3) for diffusion-sensitized driven-equilibrium turbo field echo and 1.5 × 1.9 × 3.0 mm(3) for echo-planar DWI. ADCs measured by the 2 methods in 15 regions of interests (6 in gray matter and 9 in white matter) were compared by using the Pearson correlation coefficient. The ADC in the pituitary anterior lobe was then measured in 10 volunteers by using diffusion-sensitized driven-equilibrium turbo field echo, and the results were compared with those in the pons and vermis by using a paired t test. The ADCs from the 2 methods showed a strong correlation (r = 0.79; P pituitary gland were 1.37 ± 0.13 × 10(-3) mm(2)/s, which were significantly higher than those in the pons (1.01 ± 0.24 × 10(-3) mm(2)/s) and the vermis (0.89 ± 0.25 × 10(-3) mm(2)/s, P pituitary gland.

  4. Semi-automatic segmentation of myocardium at risk in T2-weighted cardiovascular magnetic resonance.

    Science.gov (United States)

    Sjögren, Jane; Ubachs, Joey F A; Engblom, Henrik; Carlsson, Marcus; Arheden, Håkan; Heiberg, Einar

    2012-01-31

    T2-weighted cardiovascular magnetic resonance (CMR) has been shown to be a promising technique for determination of ischemic myocardium, referred to as myocardium at risk (MaR), after an acute coronary event. Quantification of MaR in T2-weighted CMR has been proposed to be performed by manual delineation or the threshold methods of two standard deviations from remote (2SD), full width half maximum intensity (FWHM) or Otsu. However, manual delineation is subjective and threshold methods have inherent limitations related to threshold definition and lack of a priori information about cardiac anatomy and physiology. Therefore, the aim of this study was to develop an automatic segmentation algorithm for quantification of MaR using anatomical a priori information. Forty-seven patients with first-time acute ST-elevation myocardial infarction underwent T2-weighted CMR within 1 week after admission. Endocardial and epicardial borders of the left ventricle, as well as the hyper enhanced MaR regions were manually delineated by experienced observers and used as reference method. A new automatic segmentation algorithm, called Segment MaR, defines the MaR region as the continuous region most probable of being MaR, by estimating the intensities of normal myocardium and MaR with an expectation maximization algorithm and restricting the MaR region by an a priori model of the maximal extent for the user defined culprit artery. The segmentation by Segment MaR was compared against inter observer variability of manual delineation and the threshold methods of 2SD, FWHM and Otsu. MaR was 32.9 ± 10.9% of left ventricular mass (LVM) when assessed by the reference observer and 31.0 ± 8.8% of LVM assessed by Segment MaR. The bias and correlation was, -1.9 ± 6.4% of LVM, R = 0.81 (p Segment MaR, -2.3 ± 4.9%, R = 0.91 (p Segment MaR and manually assessed MaR in T2-weighted CMR. Thus, the proposed algorithm seems to be a promising, objective method for standardized MaR quantification in T2

  5. Fast T1- and T2-weighted pulmonary MR-imaging in patients with bronchial carcinoma

    International Nuclear Information System (INIS)

    Both, M.; Schultze, J.; Reuter, M.; Bewig, B.; Hubner, R.; Bobis, I.; Noth, R.; Heller, M.; Biederer, J.

    2005-01-01

    Purpose: A prospective study to evaluate the diagnostic potential and limitations of three fast MRI sequences in patients with bronchial carcinoma based on the comparison with spiral CT. Material and methods: Three fast chest MRI sequences from 20 patients with central or peripheral bronchial carcinoma were evaluated by two observers for relation of tumour to adjacent structures, lymph node enlargement, additional pulmonary lesions and artefacts. The information from MR-imaging was compared with the results from spiral CT. MRI comprised a T1-3D-GRE breath-hold examination ('VIBE', TR/TE 4.5/1.9 ms, flip-angle 12 deg., matrix 502 x 512, 2.5 mm coronal slices), a breath-hold, T2-HASTE sequence (TR/TE 2000/43 ms, matrix 192 x 256, 10 mm coronal slices) and a respiration-triggered T2-TSE sequence (TR/TE 3000-6000/120 ms, matrix 270 x 512, 6 mm transverse slices). The FOV was adapted individually (380-480 mm). Results: The presence of the primary bronchial carcinoma and infiltration of thoracic structures by tumour tissue could be demonstrated by all sequences. VIBE sequence was more suitable for detecting small pulmonary nodules than the other MRI examinations, but compared to CT still 20% of these lesions were missed. Contrary to VIBE and T2-weighted TSE scans, HASTE sequence was limited in imaging mediastinal lymph nodes due to missing relevant findings in 2/20 patients. HASTE images significantly provided the lowest rate of artefacts in imaging lung parenchyma (P < 0.001 in peripheral parenchyma), but spatial resolution was limited in this sequence. Concerning the differentiation between tumour and adjacent atelectasis (n = 8), T2-weighted TSE imaging was superior to CT and VIBE in all cases and to HASTE sequence in 4/8 patients. Conclusion: The combination of VIBE and HASTE sequence allows for an adequate imaging of thoracic processes in patients with bronchial carcinoma, limited only in visualizing small pulmonary nodules. To obtain more detail resolution and to

  6. A comparison of multi-echo spin-echo and triple-echo steady-state T2 mapping for in vivo evaluation of articular cartilage

    International Nuclear Information System (INIS)

    Juras, Vladimir; Szomolanyi, Pavol; Bohndorf, Klaus; Kronnerwetter, Claudia; Hager, Benedikt; Zbyn, Stefan; Heule, Rahel; Bieri, Oliver; Trattnig, Siegfried

    2016-01-01

    To assess the clinical relevance of T 2 relaxation times, measured by 3D triple-echo steady-state (3D-TESS), in knee articular cartilage compared to conventional multi-echo spin-echo T 2 -mapping. Thirteen volunteers and ten patients with focal cartilage lesions were included in this prospective study. All subjects underwent 3-Tesla MRI consisting of a multi-echo multi-slice spin-echo sequence (CPMG) as a reference method for T 2 mapping, and 3D TESS with the same geometry settings, but variable acquisition times: standard (TESSs 4:35min) and quick (TESSq 2:05min). T 2 values were compared in six different regions in the femoral and tibial cartilage using a Wilcoxon signed ranks test and the Pearson correlation coefficient (r). The local ethics committee approved this study, and all participants gave written informed consent. The mean quantitative T 2 values measured by CPMG (mean: 46±9ms) in volunteers were significantly higher compared to those measured with TESS (mean: 31±5ms) in all regions. Both methods performed similarly in patients, but CPMG provided a slightly higher difference between lesions and native cartilage (CPMG: 90ms→61ms [31%],p=0.0125;TESS 32ms→24ms [24%],p=0.0839). 3D-TESS provides results similar to those of a conventional multi-echo spin-echo sequence with many benefits, such as shortening of total acquisition time and insensitivity to B 1 and B 0 changes. (orig.)

  7. High signal in the spinal cord on T2-weighted images in rapidly progressive tropical spastic paraparesis

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, M.; Hara, A.; Murakami, T.; Ando, Y.; Uyama, E.; Mita, S.; Uchino, M. [Kumamoto Univ. (Japan). School of Medicine; Yamashita, T. [Kumamoto Univ. (Japan). School of Medicine; Dept. of Neurology, Kumamoto Univ. (Japan)

    2001-03-01

    We report a 59-year-old woman with human T-cell lymphotrophic virus type-I (HTLV-I) associated myelopathy/tropical spastic paraparesis who showed high signal in the cervical and thoracic spinal cord on T2-weighted and contrast enhancement on T1-weighted images. (orig.)

  8. Value of fat-suppressed PD-weighted TSE-sequences for detection of anterior and posterior cruciate ligament lesions-Comparison to arthroscopy

    International Nuclear Information System (INIS)

    Schaefer, Fritz K.W.; Schaefer, Philipp J.; Brossmann, Joachim; Frahm, Christian; Muhle, Claus; Hilgert, Ralf Erik; Heller, Martin; Jahnke, Thomas

    2006-01-01

    Objective: To evaluate fat-suppressed (FS) proton-density-weighted (PDw) turbo spin-echo (TSE) magnetic resonance imaging for the detection of anterior and posterior cruciate ligament lesions in comparison to arthroscopy. Materials and methods: In a prospective study 31 knee joints were imaged on a 1.5 T MR scanner (Vision[reg], Siemens, Erlangen) prior to arthroscopy using following sequences: (a) sagittal FS-PDw/T2w TSE (TR/TE: 4009/15/105 ms); (b) sagittal PDw/T2w TSE (TR/TE:3800/15/105 ms). Further imaging parameters: slice thickness 3 mm, FOV 160 mm, matrix 256 x 256. A total of 62 anterior and posterior cruciate ligaments (ACL/PCL) were evaluated, standard of reference was arthroscopy. Sensitivity, specificity, positive (ppv) and negative predictive value (npv) and accuracy were calculated. Results: Twenty-one cruciate ligament ruptures were detected in arthroscopy, 19 ACL- and 2 PCL-ruptures (on MRI 34/124, 25/62 ACL, 9/62 PCL lesions). For all four sequences in the 31 patients with arthroscopic correlation sensitivity, specificity, ppv, npv and accuracy were 86%, 98%, 95%, 93% and 94% for detection of tears, and 84%, 100%, 100%, 80% and 90% for ACL-ruptures respectively. The two PCL-ruptures were true positive in all sequences, one intact PCL was diagnosed as torn (false positive). Conclusions: Fat-suppressed PDw/T2w TSE-MR sequences are comparable to PDw TSE sequences for the detection of ACL/PCL-lesions

  9. MR imaging of the temporomandibular joint: comparison between acquisitions at 7.0 T using dielectric pads and 3.0 T.

    Science.gov (United States)

    Kuhn, Felix P; Spinner, Georg; Del Grande, Filippo; Wyss, Michael; Piccirelli, Marco; Erni, Stefan; Pfister, Pascal; Ho, Michael; Sah, Bert-Ram; Filli, Lukas; Ettlin, Dominik A; Gallo, Luigi M; Andreisek, Gustav; Manoliu, Andrei

    2017-01-01

    To qualitatively and quantitatively compare MRI of the temporomandibular joint (TMJ) at 7.0 T using high-permittivity dielectric pads and 3.0 T using a clinical high-resolution protocol. Institutional review board-approved study with written informed consent. 12 asymptomatic volunteers were imaged at 7.0 and 3.0 T using 32-channel head coils. High-permittivity dielectric pads consisting of barium titanate in deuterated suspension were used for imaging at 7.0 T. Imaging protocol consisted of oblique sagittal proton density weighted turbo spin echo sequences. For quantitative analysis, pixelwise signal-to-noise ratio maps of the TMJ were calculated. For qualitative analysis, images were evaluated by two independent readers using 5-point Likert scales. Quantitative and qualitative results were compared using t-tests and Wilcoxon signed-rank tests, respectively. TMJ imaging at 7.0 T using high-permittivity dielectric pads was feasible in all volunteers. Quantitative analysis showed similar signal-to-noise ratio for both field strengths (mean ± SD; 7.0 T, 13.02 ± 3.92; 3.0 T, 14.02 ± 3.41; two-sample t-tests, p = 0.188). At 7.0 T, qualitative analysis yielded better visibility of all anatomical subregions of the temporomandibular disc (anterior band, intermediate zone and posterior band) than 3.0 T (Wilcoxon signed-rank tests, p 3.0 T.

  10. Clinical characteristics in normal healthy adults with microbleeds on echo-planar gradient-echo T2*-weighted MRI

    International Nuclear Information System (INIS)

    Takahashi, Wakoh; Ide, Michiru; Ohnuki, Tomohide; Takagi, Shigeharu; Shinohara, Yukito

    2004-01-01

    The gradient-echo T 2 * -weighted sequence in magnetic resonance imaging is known to be useful for detecting microbleeds (MBs) in patients with intracranial hemorrhage or lacunar stroke. We investigated the characteristics of apparently healthy adults with MBs but without stroke, employing echo-planar gradient-echo T 2 * -weighted MRI. The subjects were recruited from among 3,537 participants who underwent brain check-ups at the HIMEDIC Imaging Center. Of the 3,537 participants, 3,296 (mean age, 55±11 years) without any history of cerebrovascular disease or apparent focal neurological manifestations were selected for the present study. MBs on echo-planar gradient-echo T 2 * -weighted MRI were observed in 74 (2.2%) of the 3,296 subjects. Of a total of 133 lesions found in these 74 persons, 31 were located in the basal ganglia or cortico-subcortical regions. Thirty were in the deep white matter, 19 in the thalamus, 16 in the cerebellum, and 6 in the brain stem. The subjects with MBs were significantly older than the subjects without MBs, and the mean values for their systolic and diastolic blood pressures were higher than those in the subjects without MBs. Asymptomatic cerebral infarction, periventricular hyperintensity, and deep and subcortical white matter hyperintensity on T 1 - and T 2 -weighted MRI were more frequent in the subjects with MBs, as compared with those without MBs. Asymptomatic cerebral infarction, periventricular hyperintensity, and deep and subcortical white matter hyperintensity on T 1 - and T 2 -weighted MRI were more frequent in the subjects with MBs of the basal ganglia or thalamus than in those with MBs in other regions. MBs on echo-planar gradient-echo T 2 * -weighted MRI were thus relatively rare in apparently healthy adults. However, MBs in the basal ganglia or thalamus are suggested to be closely related to intracerebral microangiopathy. Persons with MBs in such regions should therefore be carefully checked for cerebrovascular risk

  11. Evaluation of crosstalk effect on spin-echo images at 1.5 and 3 T

    International Nuclear Information System (INIS)

    Kajisako, Masaaki; Taniguchi, Masahiro; Koizumi, Koji; Hiraga, Akira; Miyati, Tosiaki; Syakudo, Yuko; Miki, Yukio

    2011-01-01

    The purpose of this study is to evaluate the crosstalk effect on spin-echo (SE) images at 1.5 and 3 T MRI. We examined the influence of crosstalk by comparing the full width at half-maximum (FWHM) and slice profile of images of a wedge-shaped phantom for various slice gaps. We also assessed crosstalk effect in the brain by comparing image contrast among healthy volunteers (n=8). Among the subjects, the shapes of the slice profiles at 1.5 T were similar to those at 3 T for long repetition times (TRs); however, at shorter TRs, differences in slice profiles were observed among the subjects and were more apparent at 3 than at 1.5 T. The relative contrast between white matter and gray matter on T 1 -weighted images was lower at 3 than at 1.5 T. The crosstalk effect was strongest when the TR of the excitation pulse was short. The influence of the adjacent excitation pulse is important in the process of T 1 relaxation because T 1 values are greater at 3 T. In conclusion, the influence of crosstalk on SE T 1 -weighted images is greater at 3 than at 1.5 T. (author)

  12. MRI of focal liver lesions using a 1.5T turbo-spinecho technique compared with spinecho technique

    International Nuclear Information System (INIS)

    Steiner, S.; Vogl, T.J.; Fischer, P.; Steger, W.; Neuhaus, P.; Keck, H.

    1995-01-01

    In our study 35 patients with suspected focal liver lesions were examined. Standardised imaging protocol included a conventional T 2 -weighted SE sequence (T R /T E = 2000/90/45, acquisition time = 10.20) as well as a T 2 -weighted TSE sequence (T R /T E = 4700/90, acquisition time = 6.33). Calculation of S/N and C/N ratio as a basis of quantitative evaluation was done using standard methods. A diagnostic score was implemented to enable qualitative assessment. In 7% (n=2) the TSE sequence enabled detection of further liver lesions showing a size of less than 1 cm in diameter. Comparing anatomical details the TSE sequence was superior. S/N and C/N ratio of anatomic and pathologic structures of the TSE sequence were higher compared to results of the SE sequence. (orig./MG) [de

  13. Semi-automatic segmentation of myocardium at risk in T2-weighted cardiovascular magnetic resonance

    Directory of Open Access Journals (Sweden)

    Sjögren Jane

    2012-01-01

    Full Text Available Abstract Background T2-weighted cardiovascular magnetic resonance (CMR has been shown to be a promising technique for determination of ischemic myocardium, referred to as myocardium at risk (MaR, after an acute coronary event. Quantification of MaR in T2-weighted CMR has been proposed to be performed by manual delineation or the threshold methods of two standard deviations from remote (2SD, full width half maximum intensity (FWHM or Otsu. However, manual delineation is subjective and threshold methods have inherent limitations related to threshold definition and lack of a priori information about cardiac anatomy and physiology. Therefore, the aim of this study was to develop an automatic segmentation algorithm for quantification of MaR using anatomical a priori information. Methods Forty-seven patients with first-time acute ST-elevation myocardial infarction underwent T2-weighted CMR within 1 week after admission. Endocardial and epicardial borders of the left ventricle, as well as the hyper enhanced MaR regions were manually delineated by experienced observers and used as reference method. A new automatic segmentation algorithm, called Segment MaR, defines the MaR region as the continuous region most probable of being MaR, by estimating the intensities of normal myocardium and MaR with an expectation maximization algorithm and restricting the MaR region by an a priori model of the maximal extent for the user defined culprit artery. The segmentation by Segment MaR was compared against inter observer variability of manual delineation and the threshold methods of 2SD, FWHM and Otsu. Results MaR was 32.9 ± 10.9% of left ventricular mass (LVM when assessed by the reference observer and 31.0 ± 8.8% of LVM assessed by Segment MaR. The bias and correlation was, -1.9 ± 6.4% of LVM, R = 0.81 (p Conclusions There is a good agreement between automatic Segment MaR and manually assessed MaR in T2-weighted CMR. Thus, the proposed algorithm seems to be a

  14. Zero-field NMR study on a spin glass: iron-doped 2H-niobium diselenide

    International Nuclear Information System (INIS)

    Chen, M.C.

    1982-01-01

    Spin echoes are used to study the 93 Nb NQR in 2H-NbSe 2 Fe/sub x/. Measured are (intensity) x (temperature), and T/sub 1P/ (spin-lattice relaxation parameter) and T 2 (spin-spin relaxation time) as a function of temperature. Data reveal dramatic differences between non-spin glass samples (x = 0, 0.25%, 1% and 5%) and spin glass samples (x = 8%, 10% and 12%). All of the NQR results and the model calculation of the correlation times of Fe spins are best described by the phase transition picture of spin glasses

  15. Mean-Field Studies of a Mixed Spin-3/2 and Spin-2 and a Mixed Spin-3/2 and Spin-5/2 Ising System with Different Anisotropies

    International Nuclear Information System (INIS)

    Wei Guozhu; Miao Hailing

    2009-01-01

    The magnetic properties of a mixed spin-3/2 and spin-2 and a mixed spin-3/2 and spin-5/2 Ising ferromagnetic system with different anisotropies are studied by means of mean-field theory (MFT). The dependence of the phase diagram on single-ion anisotropy strengths is studied too. In the mixed spin-3/2 and spin-2 Ising model, besides the second-order phase transition, the first order-disorder phase transition and the tricritical line are found. In the mixed spin-3/2 and spin-5/2 Ising model, there is no first-order transition and tricritical line. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  16. Optimizing T2-weighted magnetic resonance sequences for surface coil microimaging of the eye with regard to lid, eyeball and head moving artifacts.

    Science.gov (United States)

    Obata, Takayuki; Uemura, Koji; Nonaka, Hiroi; Tamura, Mitsuru; Tanada, Shuji; Ikehira, Hiroo

    2006-01-01

    To acquire high-resolution magnetic resonance (MR) images, we developed a new blinking artifact reduced pulse (BARP) sequence with a surface coil specialized for microscopic imaging (47 mm in diameter). To reduce eye movement, we ascertained that the subjects' eyes were kept open and fixated to the target in the 1.5-T MR gantry. To reduce motion artifacts from blinking, we inserted rest periods for blinking (1.5 s within every 5 s) during MR scanning (T2-weighted fast spin echo; repetition time, 5 s; echo time, 100 ms; echo train, 11; matrix, 256 x 128; field of view, 5 cm; 1-mm thickness x 30 slices). Three scans (100 s x 3) were performed for each normal subject, and they were added together after automatic adjustment for location to reduce quality loss caused by head motion. T2-weighted MR images were acquired with a high resolution and a high signal-to-noise ratio. Motion artifacts were reduced with BARP, as compared with those with random blinking. Intraocular structures such as the iris and ciliary muscles were clearly visualized. Because the whole eye can be covered with a 1-mm thickness by this method, three-dimensional maps can easily be generated from the obtained images. The application of BARP with a surface coil of the human eye might become a useful and widely adopted procedure for MR microimaging.

  17. Optimisation of T{sub 2}{sup *}-weighted MRI for the detection of small veins in multiple sclerosis at 3 T and 7 T

    Energy Technology Data Exchange (ETDEWEB)

    Dixon, Jennifer Elizabeth, E-mail: jennifer.dixon@nottingham.ac.uk [Sir Peter Mansfield Magnetic Resonance Centre, University of Nottingham, Nottingham, NG7 2RD (United Kingdom); Simpson, Ashley, E-mail: ashley.simpson@nhs.net [Academic Division of Clinical Neurology, University of Nottingham, Queen' s Medical Centre, Nottingham, NG7 2UH (United Kingdom); Mistry, Niraj, E-mail: niraj.mistry@nottingham.ac.uk [Academic Division of Clinical Neurology, University of Nottingham, Queen' s Medical Centre, Nottingham, NG7 2UH (United Kingdom); Evangelou, Nikos, E-mail: nikos.evangelou@nuh.nhs.uk [Academic Division of Clinical Neurology, University of Nottingham, Queen' s Medical Centre, Nottingham, NG7 2UH (United Kingdom); Morris, Peter Gordon, E-mail: peter.morris@nottingham.ac.uk [Sir Peter Mansfield Magnetic Resonance Centre, University of Nottingham, Nottingham, NG7 2RD (United Kingdom)

    2013-05-15

    T{sub 2}{sup *}-weighted magnetic resonance imaging at 7 T has recently been shown to allow differentiation between white-matter multiple sclerosis lesions and asymptomatic white-matter lesions, by the presence or absence of a detectable central blood vessel. The aim of the present work is to improve the technique by increasing the sensitivity to veins at both 3 T and 7 T, and to assess the benefit of ultra-high-field imaging. Signal-to-noise ratio (SNR) measurements and simulations are used to compare the sensitivity of magnitude T{sub 2}{sup *}-weighted and susceptibility-weighted images for the detection of small veins (<1 pixel in diameter), both with and without the use of gadolinium. The simulations are used to predict the optimal scanning parameters in order to increase the sensitivity to these veins at both field strengths, and to reduce the inherent dependence on vessel orientation. The sensitivities of the sequences at both field strengths are compared, theoretically and experimentally, in order to quantify the benefit of imaging at ultra-high-field. Subjects with multiple sclerosis (MS) are scanned at both field strengths, using the optimised sequence parameters, as well as those used in previously published work, and the optimisation is shown to improve the detection of veins within lesions.

  18. Electrical detection of spin-momentum locking in Bi2Se3(Conference Presentation)

    Science.gov (United States)

    Jonker, Berend T.; Li, Connie H.; van't Erve, Olaf M.; Liu, Y.; Li, Y. Y.; Li, Lian

    2016-10-01

    Topological insulators (TIs) exhibit topologically protected metallic surface states populated by massless Dirac fermions with spin-momentum locking - the carrier spin lies in-plane, locked at right angle to the carrier momentum. An unpolarized charge current should thus create a net spin polarization. Here we show direct electrical detection of this bias current induced spin polarization as a voltage measured on a ferromagnetic (FM) metal tunnel barrier surface contact [1]. The voltage measured at this contact is proportional to the projection of the TI spin polarization onto this axis, and similar data are obtained for two different FM contact structures, Fe/Al2O3 and Co/MgO/graphene. From measurements of the carrier type and sign of the spin voltage for n-Bi2Se3 and p-Sb2Te3, we show that transport measurements can be used to determine the chirality of the spin texture [2]. The chirality inverts as one crosses the Dirac point, so that the carrier spin-momentum locking follows a left-hand rule (clockwise chirality) when the Fermi level is above the Dirac point, and right-hand rule below (counter-clockwise chirality). These results demonstrate simple and direct electrical access to the TI Dirac surface state spin system, provide clear evidence for the spin-momentum locking and bias current-induced spin polarization, and enable utilization of these remarkable properties for future technological applications. [1] C. H. Li, O. M. J. van `t Erve, J. T. Robinson, Y. Liu, L. Li , and B. T. Jonker, Nature Nanotech. 9, 218 (2014). [2] C. H. Li, O. M. J. van `t Erve, Y. Y. Li, L. Li and B. T. Jonker, under review.

  19. Acquired degenerative changes of the intervertebral segments at and suprajacent to the lumbosacral junction A radioanatomic analysis of the nondiscal structures of the spinal column and perispinal soft tissues

    International Nuclear Information System (INIS)

    Jinkins, J. Randy

    2004-01-01

    A review of the imaging features of normal and degenerative anatomy of the spine on medical imaging studies shows features that have been largely overlooked or poorly understood by the imaging community in recent years. The imaging methods reviewed included computed tomography (CT) with multiplanar reconstructions and magnetic resonance imaging (MRI). A routine part of the MRI examination included fat-suppressed T2 weighted fast-spin- or turbo-spin-echo acquisitions. As compared to the normal features in asymptomatic volunteers, alterations in the observed CT/MRI morphology and MR signal characteristics were sought in symptomatic individuals. Findings in symptomatic subjects which departed from the normal anatomic features of the posterior spinal elements in asymptomatic volunteers included: rupture of the interspinous ligament(s), neoarthrosis of the interspinous space with perispinous cyst formation, posterior spinal facet (zygapophyseal joint) arthrosis, related central spinal canal, lateral recess (subarticular zone) and neural foramen stenosis, posterior element alterations associated with various forms of spondylolisthesis, and perispinal muscle rupture/degeneration. These findings indicate that the posterior elements are major locations of degenerative spinal and perispinal disease that may accompany or even precede degenerative disc disease. Although not as yet proven as a reliable source of patient signs and symptoms in all individuals, because these observations may be seen in patients with radicular, referred and/or local low back pain, they should be considered in the evaluation of the symptomatic patient presenting with a clinical lumbosacral syndrome. Imaging recommendations, in addition to the usual close scrutiny of these posterior spinal elements and perispinal soft tissues on CT and MRI, include the acquisition of high-resolution multiplanar CT reconstructions, and fat-suppressed T2 weighted fast-spin- or turbo-spin-echo sequence MRI in at least

  20. Acquired degenerative changes of the intervertebral segments at and suprajacent to the lumbosacral junction A radioanatomic analysis of the nondiscal structures of the spinal column and perispinal soft tissues

    Energy Technology Data Exchange (ETDEWEB)

    Jinkins, J. Randy E-mail: jrjinkins@aol.com

    2004-05-01

    A review of the imaging features of normal and degenerative anatomy of the spine on medical imaging studies shows features that have been largely overlooked or poorly understood by the imaging community in recent years. The imaging methods reviewed included computed tomography (CT) with multiplanar reconstructions and magnetic resonance imaging (MRI). A routine part of the MRI examination included fat-suppressed T2 weighted fast-spin- or turbo-spin-echo acquisitions. As compared to the normal features in asymptomatic volunteers, alterations in the observed CT/MRI morphology and MR signal characteristics were sought in symptomatic individuals. Findings in symptomatic subjects which departed from the normal anatomic features of the posterior spinal elements in asymptomatic volunteers included: rupture of the interspinous ligament(s), neoarthrosis of the interspinous space with perispinous cyst formation, posterior spinal facet (zygapophyseal joint) arthrosis, related central spinal canal, lateral recess (subarticular zone) and neural foramen stenosis, posterior element alterations associated with various forms of spondylolisthesis, and perispinal muscle rupture/degeneration. These findings indicate that the posterior elements are major locations of degenerative spinal and perispinal disease that may accompany or even precede degenerative disc disease. Although not as yet proven as a reliable source of patient signs and symptoms in all individuals, because these observations may be seen in patients with radicular, referred and/or local low back pain, they should be considered in the evaluation of the symptomatic patient presenting with a clinical lumbosacral syndrome. Imaging recommendations, in addition to the usual close scrutiny of these posterior spinal elements and perispinal soft tissues on CT and MRI, include the acquisition of high-resolution multiplanar CT reconstructions, and fat-suppressed T2 weighted fast-spin- or turbo-spin-echo sequence MRI in at least

  1. A comparison of multi-echo spin-echo and triple-echo steady-state T2 mapping for in vivo evaluation of articular cartilage.

    Science.gov (United States)

    Juras, Vladimir; Bohndorf, Klaus; Heule, Rahel; Kronnerwetter, Claudia; Szomolanyi, Pavol; Hager, Benedikt; Bieri, Oliver; Zbyn, Stefan; Trattnig, Siegfried

    2016-06-01

    To assess the clinical relevance of T2 relaxation times, measured by 3D triple-echo steady-state (3D-TESS), in knee articular cartilage compared to conventional multi-echo spin-echo T2-mapping. Thirteen volunteers and ten patients with focal cartilage lesions were included in this prospective study. All subjects underwent 3-Tesla MRI consisting of a multi-echo multi-slice spin-echo sequence (CPMG) as a reference method for T2 mapping, and 3D TESS with the same geometry settings, but variable acquisition times: standard (TESSs 4:35min) and quick (TESSq 2:05min). T2 values were compared in six different regions in the femoral and tibial cartilage using a Wilcoxon signed ranks test and the Pearson correlation coefficient (r). The local ethics committee approved this study, and all participants gave written informed consent. The mean quantitative T2 values measured by CPMG (mean: 46±9ms) in volunteers were significantly higher compared to those measured with TESS (mean: 31±5ms) in all regions. Both methods performed similarly in patients, but CPMG provided a slightly higher difference between lesions and native cartilage (CPMG: 90ms→61ms [31%],p=0.0125;TESS 32ms→24ms [24%],p=0.0839). 3D-TESS provides results similar to those of a conventional multi-echo spin-echo sequence with many benefits, such as shortening of total acquisition time and insensitivity to B1 and B0 changes. • 3D-TESS T 2 mapping provides clinically comparable results to CPMG in shorter scan-time. • Clinical and investigational studies may benefit from high temporal resolution of 3D-TESS. • 3D-TESS T 2 values are able to differentiate between healthy and damaged cartilage.

  2. An overview of turbo decoding on fading channels

    OpenAIRE

    ATILGAN, Doğan

    2009-01-01

    A review of turbo coding and decoding has been presented in the literature [1]. In that paper, turbo coding and decoding on AWGN (Additive White Gaussian Noise) channels has been elaborated. In wireless communications, a phenomennon called multipath fading is frequently encountered. Therefore, investigation of efficient techniques to tackle with the destructive effects of fading is essential. Turbo coding has been proven as an efficient channel coding technique for AWGN channels. Some of the ...

  3. Functional MR imaging of the Eustachian tube in patients with clinically proven dysfunction: correlation with lesions detected on MR images

    Energy Technology Data Exchange (ETDEWEB)

    Luekens, Anna; Guenther, Rolf W. [University Hospital, University of Technology (RWTH) Aachen, Department of Diagnostic Radiology, Aachen (Germany); DiMartino, Ercole [Ev. Diakonie-Krankenhaus, Department of Otolaryngology and Head- and Neck-Surgery, Bremen (Germany); Krombach, Gabriele A. [University Hospital, University of Technology (RWTH) Aachen, Department of Diagnostic Radiology, Aachen (Germany); University Hospital Giessen, University Giessen, Department of Diagnostic and Interventional Radiology, Giessen (Germany)

    2012-03-15

    To visualise the function of the Eustachian tube by MRI and assess the effect of surrounding lesions. Using 1.5 T MRI, 32 Eustachian tubes of 16 patients with clinically proven dysfunction (clinical symptoms, such as autophonia and fullness and non-opening at tympanometry) were investigated. For depiction of the anatomy and associated abnormalities, coronal and axial T2-weighted turbo spin echo sequences and a T1-weighted-2D-gradient echo sequences were acquired. Eustachian tube opening was analysed with real time turbo-gradient echo sequences during a Valsalva manoeuvre. Dysfunction, that is, failure of opening of the Eustachian tube as shown by MRI, correlated in all patients with tympanometry. Lesions detected included nasopharyngeal carcinoma in 4 patients. Mucosal swelling in the paranasal sinus was present in 9 patients. One patient had postoperative defects. In two patients both pharyngotympanic tubes did not open although no structural abnormalities could be depicted. The opening of the Eustachian tubes during the Valsalva manoeuvre is assessable on MRI. Failure of opening may be due to swelling of the mucosa and may be also associated with tumours. MRI assessment may be helpful in patients with chronic otitis media, where the information about tubal function is important in preoperative planning. (orig.)

  4. Colorectal carcinoma: Ex vivo evaluation using 3-T high-spatial-resolution quantitative T2 mapping and its correlation with histopathologic findings.

    Science.gov (United States)

    Yamada, Ichiro; Yoshino, Norio; Hikishima, Keigo; Miyasaka, Naoyuki; Yamauchi, Shinichi; Uetake, Hiroyuki; Yasuno, Masamichi; Saida, Yukihisa; Tateishi, Ukihide; Kobayashi, Daisuke; Eishi, Yoshinobu

    2017-05-01

    In this study, we aimed to evaluate the feasibility of determining the mural invasion depths of colorectal carcinomas using high-spatial-resolution (HSR) quantitative T2 mapping on a 3-T magnetic resonance (MR) scanner. Twenty colorectal specimens containing adenocarcinomas were imaged on a 3-T MR system equipped with a 4-channel phased-array surface coil. HSR quantitative T2 maps were acquired using a spin-echo sequence with a repetition time/echo time of 7650/22.6-361.6ms (16 echoes), 87×43.5-mm field of view, 2-mm section thickness, 448×224 matrix, and average of 1. HSR fast-spin-echo T2-weighted images were also acquired. Differences between the T2 values (ms) of the tumor tissue, colorectal wall layers, and fibrosis were measured, and the MR images and histopathologic findings were compared. In all specimens (20/20, 100%), the HSR quantitative T2 maps clearly depicted an 8-layer normal colorectal wall in which the T2 values of each layer differed from those of the adjacent layer(s) (PT2 maps and histopathologic data yielded the same findings regarding the tumor invasion depth. Our results indicate that 3-T HSR quantitative T2 mapping is useful for distinguishing colorectal wall layers and differentiating tumor and fibrotic tissues. Accordingly, this technique could be used to determine mural invasion by colorectal carcinomas with a high level of accuracy. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. T2-weighted MRI-derived textural features reflect prostate cancer aggressiveness: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Nketiah, Gabriel; Elschot, Mattijs; Kim, Eugene; Teruel, Jose R. [NTNU, Norwegian University of Science and Technology, Department of Circulation and Medical Imaging, Faculty of Medicine, Trondheim (Norway); Scheenen, Tom W. [Radboud University Medical Center, Department of Radiology and Nuclear Medicine, Nijmegen (Netherlands); Bathen, Tone F.; Selnaes, Kirsten M. [NTNU, Norwegian University of Science and Technology, Department of Circulation and Medical Imaging, Faculty of Medicine, Trondheim (Norway); St. Olavs Hospital, Trondheim University Hospital, Trondheim (Norway)

    2017-07-15

    To evaluate the diagnostic relevance of T2-weighted (T2W) MRI-derived textural features relative to quantitative physiological parameters derived from diffusion-weighted (DW) and dynamic contrast-enhanced (DCE) MRI in Gleason score (GS) 3+4 and 4+3 prostate cancers. 3T multiparametric-MRI was performed on 23 prostate cancer patients prior to prostatectomy. Textural features [angular second moment (ASM), contrast, correlation, entropy], apparent diffusion coefficient (ADC), and DCE pharmacokinetic parameters (K{sup trans} and V{sub e}) were calculated from index tumours delineated on the T2W, DW, and DCE images, respectively. The association between the textural features and prostatectomy GS and the MRI-derived parameters, and the utility of the parameters in differentiating between GS 3+4 and 4+3 prostate cancers were assessed statistically. ASM and entropy correlated significantly (p < 0.05) with both GS and median ADC. Contrast correlated moderately with median ADC. The textural features correlated insignificantly with K{sup trans} and V{sub e}. GS 4+3 cancers had significantly lower ASM and higher entropy than 3+4 cancers, but insignificant differences in median ADC, K{sup trans}, and V{sub e}. The combined texture-MRI parameters yielded higher classification accuracy (91%) than the individual parameter sets. T2W MRI-derived textural features could serve as potential diagnostic markers, sensitive to the pathological differences in prostate cancers. (orig.)

  6. Assessment of Silent T1-weighted head imaging at 7 T

    Energy Technology Data Exchange (ETDEWEB)

    Costagli, Mauro; Tiberi, Gianluigi; Tosetti, Michela [Imago7 Foundation, Pisa (Italy); IRCCS Stella Maris, Laboratory of Medical Physics and Biotechnologies for Magnetic Resonance, Pisa (Italy); Symms, Mark R. [GE Applied Science Laboratory, Pisa (Italy); Angeli, Lorenzo [University of Pisa, Department of Translational Research and New Technologies in Medicine and Surgery, Pisa (Italy); Kelley, Douglas A.C. [GE Healthcare Technologies, San Francisco, CA (United States); Biagi, Laura [IRCCS Stella Maris, Laboratory of Medical Physics and Biotechnologies for Magnetic Resonance, Pisa (Italy); Farnetani, Andrea [University of Ferrara, Engineering Department, Ferrara (Italy); Materiacustica s.r.l., Ferrara (Italy); Rua, Catarina [University of Pisa, Department of Physics, Pisa (Italy); Donatelli, Graziella [Azienda Ospedaliero-Universitaria Pisana (AOUP), Neuroradiology Unit, Department of Diagnostic and Interventional Radiology, Pisa (Italy); Cosottini, Mirco [Imago7 Foundation, Pisa (Italy); University of Pisa, Department of Translational Research and New Technologies in Medicine and Surgery, Pisa (Italy)

    2016-06-15

    This study aimed to assess the performance of a ''Silent'' zero time of echo (ZTE) sequence for T1-weighted brain imaging using a 7 T MRI system. The Silent sequence was evaluated qualitatively by two neuroradiologists, as well as quantitatively in terms of tissue contrast, homogeneity, signal-to-noise ratio (SNR) and acoustic noise. It was compared to conventional T1-weighted imaging (FSPGR). Adequacy for automated segmentation was evaluated in comparison with FSPGR acquired at 7 T and 1.5 T. Specific absorption rate (SAR) was also measured. Tissue contrast and homogeneity in Silent were remarkable in deep brain structures and in the occipital and temporal lobes. Mean tissue contrast was significantly (p < 0.002) higher in Silent (0.25) than in FSPGR (0.11), which favoured automated tissue segmentation. On the other hand, Silent images had lower SNR with respect to conventional imaging: average SNR of FSPGR was 2.66 times that of Silent. Silent images were affected by artefacts related to projection reconstruction, which nevertheless did not compromise the depiction of brain tissues. Silent acquisition was 35 dB(A) quieter than FSPGR and less than 2.5 dB(A) louder than ambient noise. Six-minute average SAR was <2 W/kg. The ZTE Silent sequence provides high-contrast T1-weighted imaging with low acoustic noise at 7 T. (orig.)

  7. Low flip angle spin-echo MR imaging to obtain better Gd-DTPA enhanced imaging with ECG gating

    International Nuclear Information System (INIS)

    Sugimura, Kazuro; Kawamitsu, Hideaki; Yoshikawa, Kazuaki; Kasai, Toshifumi; Yuasa, Koji; Ishida, Tetsuya

    1992-01-01

    ECG-gated spin-echo imaging (ECG-SE) can reduce physiological motion artifact. However, ECG-SE does not provide strong T1-weighted images because repetition time (TR) depends on heart rate (HR). We investigated the usefulness of low flip angle spin-echo imaging (LFSE) in obtaining more T1-dependent contrast with ECG gating. In computer simulation, the predicted image contrast and single-to-noise ratio (SNR) obtained for each flip angle (0-180deg) and each TR (300 msec-1200 msec) were compared with those obtained by conventional T1-weighted spin-echo imaging (CSE: TR=500 msec, TE=20 msec). In clinical evaluation, tissue contrast [contrast index (CI): (SI of lesion-SI of muslce) 2* 100/SI of muscle] obtained by CSE and LFSE were compared in 17 patients. At a TR of 1,000 msec, T1-dependent contrast increased with decreasing flip angle and that at 38deg was identical to that with T1-weighted spin-echo. SNR increased with the flip angle until 100deg, and that at 53deg was identical to that with T1-weighted spin-echo. CI on LFSE (74.0±52.0) was significantly higher than CI on CSE (40.9±35.9). ECG-gated LFSE imaging provides better T1-dependent contrast than conventional ECG-SE. This method was especially useful for Gd-DTPA enhanced MR imaging. (author)

  8. A comparison of multi-echo spin-echo and triple-echo steady-state T2 mapping for in vivo evaluation of articular cartilage

    Energy Technology Data Exchange (ETDEWEB)

    Juras, Vladimir; Szomolanyi, Pavol [Medical University of Vienna, High Field MR Centre, Department of Biomedical Imaging and Image-Guided Therapy, Vienna (Austria); Institute of Measurement Science, Department of Imaging Methods, Bratislava (Slovakia); Bohndorf, Klaus; Kronnerwetter, Claudia; Hager, Benedikt; Zbyn, Stefan [Medical University of Vienna, High Field MR Centre, Department of Biomedical Imaging and Image-Guided Therapy, Vienna (Austria); Heule, Rahel; Bieri, Oliver [University of Basel Hospital, Division of Radiological Physics, Department of Radiology, Basel (Switzerland); Trattnig, Siegfried [Medical University of Vienna, High Field MR Centre, Department of Biomedical Imaging and Image-Guided Therapy, Vienna (Austria); Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna (Austria); Ludwig Boltzmann Institute for Experimental and Clinical Traumatology, Austrian Cluster for Tissue Regeneration, Vienna (Austria)

    2016-06-15

    To assess the clinical relevance of T{sub 2} relaxation times, measured by 3D triple-echo steady-state (3D-TESS), in knee articular cartilage compared to conventional multi-echo spin-echo T{sub 2}-mapping. Thirteen volunteers and ten patients with focal cartilage lesions were included in this prospective study. All subjects underwent 3-Tesla MRI consisting of a multi-echo multi-slice spin-echo sequence (CPMG) as a reference method for T{sub 2} mapping, and 3D TESS with the same geometry settings, but variable acquisition times: standard (TESSs 4:35min) and quick (TESSq 2:05min). T{sub 2} values were compared in six different regions in the femoral and tibial cartilage using a Wilcoxon signed ranks test and the Pearson correlation coefficient (r). The local ethics committee approved this study, and all participants gave written informed consent. The mean quantitative T{sub 2} values measured by CPMG (mean: 46±9ms) in volunteers were significantly higher compared to those measured with TESS (mean: 31±5ms) in all regions. Both methods performed similarly in patients, but CPMG provided a slightly higher difference between lesions and native cartilage (CPMG: 90ms→61ms [31%],p=0.0125;TESS 32ms→24ms [24%],p=0.0839). 3D-TESS provides results similar to those of a conventional multi-echo spin-echo sequence with many benefits, such as shortening of total acquisition time and insensitivity to B{sub 1} and B{sub 0} changes. (orig.)

  9. Reduction of respiratory ghosting motion artifacts in conventional two-dimensional multi-slice Cartesian turbo spin-echo: which k-space filling order is the best?

    Science.gov (United States)

    Inoue, Yuuji; Yoneyama, Masami; Nakamura, Masanobu; Takemura, Atsushi

    2018-06-01

    The two-dimensional Cartesian turbo spin-echo (TSE) sequence is widely used in routine clinical studies, but it is sensitive to respiratory motion. We investigated the k-space orders in Cartesian TSE that can effectively reduce motion artifacts. The purpose of this study was to demonstrate the relationship between k-space order and degree of motion artifacts using a moving phantom. We compared the degree of motion artifacts between linear and asymmetric k-space orders. The actual spacing of ghost artifacts in the asymmetric order was doubled compared with that in the linear order in the free-breathing situation. The asymmetric order clearly showed less sensitivity to incomplete breath-hold at the latter half of the imaging period. Because of the actual number of partitions of the k-space and the temporal filling order, the asymmetric k-space order of Cartesian TSE was superior to the linear k-space order for reduction of ghosting motion artifacts.

  10. Comparison of 3 T and 7 T MRI clinical sequences for ankle imaging

    Energy Technology Data Exchange (ETDEWEB)

    Juras, Vladimir, E-mail: vladimir.juras@meduniwien.ac.at [Medical University of Vienna, Department of Radiology, Vienna General Hospital, Waeringer Guertel 18-20, A-1090 Vienna (Austria); Slovak Academy of Sciences, Institute of Measurement Science, Dubravska cesta 9, 84104 Bratislava (Slovakia); Welsch, Goetz, E-mail: welsch@bwh.harvard.edu [Medical University of Vienna, Department of Radiology, Vienna General Hospital, Waeringer Guertel 18-20, A-1090 Vienna (Austria); Baer, Peter, E-mail: baerpeter@siemens.com [Siemens Healthcare, Richard-Strauss-Strasse 76, D81679 Munich (Germany); Kronnerwetter, Claudia, E-mail: claudia.kronnerwetter@meduniwien.ac.at [Medical University of Vienna, Department of Radiology, Vienna General Hospital, Waeringer Guertel 18-20, A-1090 Vienna (Austria); Fujita, Hiroyuki, E-mail: hiroyuki.fujita@qualedyn.com [Quality Electrodynamics, LCC, 777 Beta Dr, Cleveland, OH 44143-2336 (United States); Trattnig, Siegfried, E-mail: siegfried.trattnig@meduniwien.ac.at [Medical University of Vienna, Department of Radiology, Vienna General Hospital, Waeringer Guertel 18-20, A-1090 Vienna (Austria)

    2012-08-15

    The purpose of this study was to compare 3 T and 7 T signal-to-noise and contrast-to noise ratios of clinical sequences for imaging of the ankles with optimized sequences and dedicated coils. Ten healthy volunteers were examined consecutively on both systems with three clinical sequences: (1) 3D gradient-echo, T{sub 1}-weighted; (2) 2D fast spin-echo, PD-weighted; and (3) 2D spin-echo, T{sub 1}-weighted. SNR was calculated for six regions: cartilage; bone; muscle; synovial fluid; Achilles tendon; and Kager's fat-pad. CNR was obtained for cartilage/bone, cartilage/fluid, cartilage/muscle, and muscle/fat-pad, and compared by a one-way ANOVA test for repeated measures. Mean SNR significantly increased at 7 T compared to 3 T for 3D GRE, and 2D TSE was 60.9% and 86.7%, respectively. In contrast, an average SNR decrease of almost 25% was observed in the 2D SE sequence. A CNR increase was observed in 2D TSE images, and in most 3D GRE images. There was a substantial benefit from ultra high-field MR imaging of ankles with routine clinical sequences at 7 T compared to 3 T. Higher SNR and CNR at ultra-high field MR scanners may be useful in clinical practice for ankle imaging. However, carefully optimized protocols and dedicated extremity coils are necessary to obtain optimal results.

  11. Structural dynamics of turbo-machines

    CERN Document Server

    Rangwala, AS

    2009-01-01

    The book presents a detailed and comprehensive treatment of structural vibration evaluation of turbo-machines. Starting with the fundamentals of the theory of vibration as related to various aspects of rotating machines, the dynamic analysis procedures of a broad spectrum of turbo-machines is covered. An in-depth procedure for analyzing the torsional and flexural oscillations of the components and of the rotor-bearing system is presented. The latest trends in design and analysis are presented, chief among them: Blade and coupled disk-blade mod

  12. Performance improvement of standard turbo-compressor; Han`yo turbo asshukuki no seino kaizen

    Energy Technology Data Exchange (ETDEWEB)

    Hokari, T.; Hasegawa, K.; Ozaki, S.; Majima, K. [Ishikawajima-Harima Heavy Industries Co. Ltd., Tokyo (Japan)

    1999-05-01

    Abradable materials are soft and cause no contact damage to the impeller of the turbo-compressor. Using such materials for the inlet casing facing to the impeller allows very small clearances between the impeller and inlet casing, thus improving the compressor efficiency by 10% over conventional types. Changing the area of abradable material applied to the inlet casing identified the optimum area in which decrease of the compressor surge margin is minimized and efficiency is improved by 10%. As a result, turbo-compressors have the best performance when the abradable materials are applied from the impeller outlet to two-thirds of the forward location of the inlet casing. (author)

  13. Registration of T2-weighted and diffusion-weighted MR images of the prostate: comparison between manual and landmark-based methods

    Science.gov (United States)

    Peng, Yahui; Jiang, Yulei; Soylu, Fatma N.; Tomek, Mark; Sensakovic, William; Oto, Aytekin

    2012-02-01

    Quantitative analysis of multi-parametric magnetic resonance (MR) images of the prostate, including T2-weighted (T2w) and diffusion-weighted (DW) images, requires accurate image registration. We compared two registration methods between T2w and DW images. We collected pre-operative MR images of 124 prostate cancer patients (68 patients scanned with a GE scanner and 56 with Philips scanners). A landmark-based rigid registration was done based on six prostate landmarks in both T2w and DW images identified by a radiologist. Independently, a researcher manually registered the same images. A radiologist visually evaluated the registration results by using a 5-point ordinal scale of 1 (worst) to 5 (best). The Wilcoxon signed-rank test was used to determine whether the radiologist's ratings of the results of the two registration methods were significantly different. Results demonstrated that both methods were accurate: the average ratings were 4.2, 3.3, and 3.8 for GE, Philips, and all images, respectively, for the landmark-based method; and 4.6, 3.7, and 4.2, respectively, for the manual method. The manual registration results were more accurate than the landmark-based registration results (p < 0.0001 for GE, Philips, and all images). Therefore, the manual method produces more accurate registration between T2w and DW images than the landmark-based method.

  14. Iterative Estimation in Turbo Equalization Process

    Directory of Open Access Journals (Sweden)

    MORGOS Lucian

    2014-05-01

    Full Text Available This paper presents the iterative estimation in turbo equalization process. Turbo equalization is the process of reception in which equalization and decoding are done together, not as separate processes. For the equalizer to work properly, it must receive before equalization accurate information about the value of the channel impulse response. This estimation of channel impulse response is done by transmission of a training sequence known at reception. Knowing both the transmitted and received sequence, it can be calculated estimated value of the estimated the channel impulse response using one of the well-known estimation algorithms. The estimated value can be also iterative recalculated based on the sequence data available at the output of the channel and estimated sequence data coming from turbo equalizer output, thereby refining the obtained results.

  15. The value of T1-weighted images in the differentiation between MS, white matter lesions, and subcortical arteriosclerotic encephalopathy (SAE)

    Energy Technology Data Exchange (ETDEWEB)

    Uhlenbrock, D.; Sehlen, S.

    1989-07-01

    The aim of the study was to define reliable criteria for the differentiation of MR imaging between patients with MS and with 'vascular' white matter lesions/SAE. We examined 35 patients with proven MS according to the Poser criteria and 35 patients with other white matter lesions and/or SAE. The result is that with MR a differentiation can be achieved provided that T1-weighted spin-echo sequences are included and the different pattern of distribution is considered. MS plaques are predominantly located in the subependymal region, vascular white matter lesions are mainly located in the water-shed of the superficial middle cerebral branches and the deep perforating long medullary vessels in the centrum semiovale. Infratentorial lesions are more often seen in MS. Confluence at the lateral ventricles is frequently accompanied by confluent abnormalities around the third ventricle, Sylvian aqueduct, and fourth ventricle, which is uncommon in SAE. In MS many lesions visible on T2-weighted images have a cellular or intracellular composition that renders them visible also on T1-weighted ones as regions with low signal intensity and more or less distinct boundary. 'Vascular' white matter lesions and SAE mainly represent demyelination and can therefore be seen on T2-weighted images, but corresponding low signal intensity lesions on T1-weighted images are uncommon. In some exceptions there are such lesions with low signal representing lacunar infarcts or widened Virchow-Robin-spaces. (orig.).

  16. T2-weighted endorectal magnetic resonance imaging of prostate cancer after external beam radiation therapy

    International Nuclear Information System (INIS)

    Westphalen, Antonio C.; Kurhanewicz, John; Cunha, Rui M.G.; Hsu, I-Chow; Kornak, John; Zhao, Shoujun; Coakley, Fergus V.

    2009-01-01

    Purpose: To retrospectively determine the accuracy of T2-weighted endorectal MR imaging in the detection of prostate cancer after external beam radiation therapy and to investigate the relationship between imaging accuracy and time since therapy. Materials and Methods: Institutional review board approval was obtained and the study was HIPPA compliant. We identified 59 patients who underwent 1.5 Tesla endorectal MR imaging of the prostate between 1999 and 2006 after definitive external beam radiation therapy for biopsy-proven prostate cancer. Two readers recorded the presence or absence of tumor on T2-weighted images. Logistic regression and Fisher's exact tests for 2x2 tables were used to determine the accuracy of imaging and investigate if accuracy differed between those imaged within 3 years of therapy (n = 25) and those imaged more than 3 years after therapy (n = 34). Transrectal biopsy was used as the standard of reference for the presence or absence of recurrent cancer. Results: Thirty-four of 59 patients (58%) had recurrent prostate cancer detected on biopsy. The overall accuracy of T2-weighted MR imaging in the detection cancer after external beam radiation therapy was 63% (37/59) for reader 1 and 71% for reader 2 (42/59). For both readers, logistic regression showed no difference in accuracy between those imaged within 3 years of therapy and those imaged more than 3 years after therapy (p = 0.86 for reader 1 and 0.44 for reader 2). Conclusion: T2-weighted endorectal MR imaging has low accuracy in the detection of prostate cancer after external beam radiation therapy, irrespective of the time since therapy. (author)

  17. Magnetic resonance imaging of the sacroiliac joints in patients with suspected spondyloarthritis. Comparison of turbo spin-echo and gradient-echo sequences for the detection of structural alterations; MRT-Bildgebung der Sakroiliakalgelenke bei Verdacht auf Spondyloarthritis. Vergleich von Turbospinecho- und Gradientenechosequenzen zum Nachweis struktureller Veraenderungen

    Energy Technology Data Exchange (ETDEWEB)

    Dornia, C.; Hoffstetter, P. [Universitaetsklinikum Regensburg (Germany). Inst. fuer Roentgendiagnostik; Asklepios Klinikum, Bad Abbach (Germany). Inst. fuer Roentgendiagnostik; Fleck, M. [Universitaetsklinikum Regensburg (Germany). Klinik fuer Innere Medizin I; Asklepios Klinikum, Bad Abbach (Germany). Klinik fuer Rheumatologie und Klinische Immunologie; Hartung, W. [Asklepios Klinikum, Bad Abbach (Germany). Klinik fuer Rheumatologie und Klinische Immunologie; Niessen, C.; Stroszczynski, C. [Universitaetsklinikum Regensburg (Germany). Inst. fuer Roentgendiagnostik

    2015-02-15

    Magnetic resonance imaging (MRI) is the method of choice for the evaluation of spondyloarthritis (SpA). According to the guidelines of the Assessment of Spondyloarthritis International Society (ASAS) and Outcome Measures in Rheumatology (OMERACT), MRI findings in SpA of the spine and the sacroiliac joints (SIJ) are classified as inflammatory and structural alterations. Modern gradient-echo sequences (GRE) are recommended for optimized detection of structural alterations of the SIJ. We assess the benefit of GRE in the detection of structural alterations of the SIJ in comparison to conventional turbo spin-echo sequences (TSE). Retrospective study of 114 patients who received MRI of the SIJ for the evaluation of SpA. Structural alterations of the SIJ were assessed by two blinded readers separately for T1 TSE and T2{sup *} GRE. The findings were classified according to a previously published chronicity score separately for both sides and sequences. Interobserver reliability was calculated with Cohen's Kappa, and the significance of findings was assessed with the Wilcoxon test. P-values < 0.05 were required for statistical significance. 68 of 114 (60%) patients showed SpA-typical findings of the SIJ. The average chronicity score for GRE (score 3.3) was significantly higher than for TSE (score 2.6), p=0.001. The Kappa-values for the interobserver reliability were 0.86-0.90 without any statistically significant differences between both sides and sequences. Both T1 TSE and T2{sup *} GRE showed a high interobserver reliability in the detection of structural alterations in patients with SpA. However, T2{sup *} GRE detected significantly more structural alterations than T1 TSE and should be an integral part of a modern MRI protocol for the diagnostic workup of patients with suspected SpA.

  18. A new look at the fetus: Thick-slab T2-weighted sequences in fetal MRI

    International Nuclear Information System (INIS)

    Brugger, Peter C.; Mittermayer, Christoph; Prayer, Daniela

    2006-01-01

    Although magnetic resonance imaging (MRI) of the fetus is considered an established adjunct to fetal ultrasound, stacks of images alone cannot provide an overall impression of the fetus. The present study evaluates the use of thick-slab T2-weighted MR images to obtain a three-dimensional impression of the fetus using MRI. A thick-slab T2-weighted sequence was added to the routine protocol in 100 fetal MRIs obtained for various indications (19th to 37th gestational weeks) on a 1.5 T magnet using a five-element phased-array surface coil. Slice thickness adapted to fetal size and uterine geometry varied between 25 and 50 mm, as did the field of view (250-350 mm). Acquisition of one image took less than 1 s. The pictorial essay shows that these images visualize fetal anatomy in a more comprehensive way than is possible with a series of 3-4 mm thick slices. These thick-slab images facilitate the assessment of the whole fetus, fetal proportions, surface structures, and extremities. Fetal pathology may be captured in one image. Thick-slab T2-weighted images provide additional information that cannot be gathered from a series of images and are considered a valuable adjunct to conventional 2D MR images

  19. A new look at the fetus: Thick-slab T2-weighted sequences in fetal MRI

    Energy Technology Data Exchange (ETDEWEB)

    Brugger, Peter C. [Center of Anatomy and Cell Biology, Integrative Morphology Group, Medical University of Vienna, Vienna (Austria)]. E-mail: peter.brugger@meduniwien.ac.at; Mittermayer, Christoph [Department of Neonatology and Intensive Care, University Hospital of Vienna (Austria); Prayer, Daniela [Department of Neuroradiology, University Clinics of Radiodiagnostics, Medical University of Vienna, Vienna (Austria)

    2006-02-15

    Although magnetic resonance imaging (MRI) of the fetus is considered an established adjunct to fetal ultrasound, stacks of images alone cannot provide an overall impression of the fetus. The present study evaluates the use of thick-slab T2-weighted MR images to obtain a three-dimensional impression of the fetus using MRI. A thick-slab T2-weighted sequence was added to the routine protocol in 100 fetal MRIs obtained for various indications (19th to 37th gestational weeks) on a 1.5 T magnet using a five-element phased-array surface coil. Slice thickness adapted to fetal size and uterine geometry varied between 25 and 50 mm, as did the field of view (250-350 mm). Acquisition of one image took less than 1 s. The pictorial essay shows that these images visualize fetal anatomy in a more comprehensive way than is possible with a series of 3-4 mm thick slices. These thick-slab images facilitate the assessment of the whole fetus, fetal proportions, surface structures, and extremities. Fetal pathology may be captured in one image. Thick-slab T2-weighted images provide additional information that cannot be gathered from a series of images and are considered a valuable adjunct to conventional 2D MR images.

  20. Usefulness of metal artifact reduction with WARP technique at 1.5 and 3T MRI in imaging metal-on-metal hip resurfacings

    Energy Technology Data Exchange (ETDEWEB)

    Lazik, Andrea; Lauenstein, Thomas C.; Theysohn, Jens M. [University Hospital Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Landgraeber, Stefan; Schulte, Patrick [University Hospital Essen, Department of Orthopedics, Essen (Germany); Kraff, Oliver [University of Duisburg-Essen, Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany)

    2015-03-25

    To evaluate the usefulness of the metal artifact reduction technique ''WARP'' in the assessment of metal-on-metal hip resurfacings at 1.5 and 3T in the context of image quality and imaging speed. Nineteen patients (25 hip resurfacings) were randomized for 1.5 and 3T MRI, both including T1 and T2 turbo spin-echo as well as turbo inversion recovery magnitude sequences with and without view angle tilting and high bandwidth. Additional 3T sequences were acquired with a reduced number of averages and using the parallel acquisition technique for accelerating imaging speed. Artifact size (diameter, area), image quality (5-point scale) and delineation of anatomical structures were compared among the techniques, sequences and field strengths using the Wilcoxon sign-rank and paired t-test with Bonferroni correction. At both field strengths, WARP showed significant superiority over standard sequences regarding image quality, artifact size and delineation of anatomical structures. At 3T, artifacts were larger compared to 1.5T without affecting diagnostic quality, and scanning time could be reduced by up to 64 % without quality degradation. WARP proved useful in imaging metal-on-metal hip resurfacings at 1.5T as well as 3T with better image quality surrounding the implants. At 3T imaging could be considerably accelerated without losing diagnostic quality. (orig.)

  1. Usefulness of metal artifact reduction with WARP technique at 1.5 and 3T MRI in imaging metal-on-metal hip resurfacings

    International Nuclear Information System (INIS)

    Lazik, Andrea; Lauenstein, Thomas C.; Theysohn, Jens M.; Landgraeber, Stefan; Schulte, Patrick; Kraff, Oliver

    2015-01-01

    To evaluate the usefulness of the metal artifact reduction technique ''WARP'' in the assessment of metal-on-metal hip resurfacings at 1.5 and 3T in the context of image quality and imaging speed. Nineteen patients (25 hip resurfacings) were randomized for 1.5 and 3T MRI, both including T1 and T2 turbo spin-echo as well as turbo inversion recovery magnitude sequences with and without view angle tilting and high bandwidth. Additional 3T sequences were acquired with a reduced number of averages and using the parallel acquisition technique for accelerating imaging speed. Artifact size (diameter, area), image quality (5-point scale) and delineation of anatomical structures were compared among the techniques, sequences and field strengths using the Wilcoxon sign-rank and paired t-test with Bonferroni correction. At both field strengths, WARP showed significant superiority over standard sequences regarding image quality, artifact size and delineation of anatomical structures. At 3T, artifacts were larger compared to 1.5T without affecting diagnostic quality, and scanning time could be reduced by up to 64 % without quality degradation. WARP proved useful in imaging metal-on-metal hip resurfacings at 1.5T as well as 3T with better image quality surrounding the implants. At 3T imaging could be considerably accelerated without losing diagnostic quality. (orig.)

  2. Primary biliary cirrhosis: Evaluation with T2-weighted MR imaging and MR cholangiopancreatography

    Energy Technology Data Exchange (ETDEWEB)

    Haliloglu, Nuray [Ankara University, Faculty of Medicine, Department of Radiology, Ibni Sina Hospital, 06100 Ankara (Turkey)], E-mail: nurayunsal2@hotmail.com; Erden, Ayse; Erden, Ilhan [Ankara University, Faculty of Medicine, Department of Radiology, Ibni Sina Hospital, 06100 Ankara (Turkey)

    2009-03-15

    Purpose: The aim of this retrospective study is to evaluate the role of T2-weighted MR imaging (MRI) and MR cholangiopancreatography (MRCP) findings in the diagnosis of primary biliary cirrhosis (PBC). Materials and methods: The following T2-weighted MRI and MRCP findings: segmental hepatic atrophy/hypertrophy, irregular liver surface, parenchymal lace-like fibrosis, rounded low signal intensity lesions centering portal vein branches (periportal halo sign), periportal hyperintensity (cuffing), splenomegaly, ascites, lymphadenopathy, venous collaterals, and the configuration of intrahepatic biliary ducts were reviewed for their diagnostic significance by two observers in 13 female patients (mean age: 49 years) with PBC. Discordant readings of the observers were resolved at consensus. Results: When parenchymal lace-like fibrosis and periportal halo sign were seen together the sensitivity of T2-weighted MR images was 69%. In six cases periportal hyperintensity (cuffing) and periportal halo sign were seen together. Segmental hypertrophy was present in nine patients and hepatic surface irregularity due to regenerative nodules were present in 10 patients. Lymphadenopathy was seen in 10, splenomegaly was seen in 5, collateral vascular structures were seen in 2 and minimal perihepatic free fluid was seen in 2 patients. MRCP images revealed various mild irregularity in the intrahepatic bile ducts in 8 patients and focal narrowing at the common bile duct level in 1 patient. Conclusion: MRI and MRCP may support the clinical and laboratory findings of PBC even in the early stages of the disease. MRI can also be a choice of method for the recommended prolonged follow up.

  3. Primary biliary cirrhosis: Evaluation with T2-weighted MR imaging and MR cholangiopancreatography

    International Nuclear Information System (INIS)

    Haliloglu, Nuray; Erden, Ayse; Erden, Ilhan

    2009-01-01

    Purpose: The aim of this retrospective study is to evaluate the role of T2-weighted MR imaging (MRI) and MR cholangiopancreatography (MRCP) findings in the diagnosis of primary biliary cirrhosis (PBC). Materials and methods: The following T2-weighted MRI and MRCP findings: segmental hepatic atrophy/hypertrophy, irregular liver surface, parenchymal lace-like fibrosis, rounded low signal intensity lesions centering portal vein branches (periportal halo sign), periportal hyperintensity (cuffing), splenomegaly, ascites, lymphadenopathy, venous collaterals, and the configuration of intrahepatic biliary ducts were reviewed for their diagnostic significance by two observers in 13 female patients (mean age: 49 years) with PBC. Discordant readings of the observers were resolved at consensus. Results: When parenchymal lace-like fibrosis and periportal halo sign were seen together the sensitivity of T2-weighted MR images was 69%. In six cases periportal hyperintensity (cuffing) and periportal halo sign were seen together. Segmental hypertrophy was present in nine patients and hepatic surface irregularity due to regenerative nodules were present in 10 patients. Lymphadenopathy was seen in 10, splenomegaly was seen in 5, collateral vascular structures were seen in 2 and minimal perihepatic free fluid was seen in 2 patients. MRCP images revealed various mild irregularity in the intrahepatic bile ducts in 8 patients and focal narrowing at the common bile duct level in 1 patient. Conclusion: MRI and MRCP may support the clinical and laboratory findings of PBC even in the early stages of the disease. MRI can also be a choice of method for the recommended prolonged follow up.

  4. Magnetic structure and spin dynamics of the quasi-one-dimensional spin-chain antiferromagnet BaCo2V2O8

    DEFF Research Database (Denmark)

    Kawasaki, Yu; Gavilano, Jorge L.; Keller, Lukas

    2011-01-01

    ,0,1), independent of external magnetic fields for fields below a critical value H-c(T). The ordered moments of 2.18 mu(B) per Co ion are aligned along the crystallographic c axis. Within the screw chains, along the c axis, the moments are arranged antiferromagnetically. In the basal planes the spins are arranged......We report a neutron diffraction and muon spin relaxation mu SR study of static and dynamical magnetic properties of BaCo2V2O8, a quasi-one-dimensional spin-chain system. A proposed model for the antiferromagnetic structure includes: a propagation vector (k) over right arrow (AF) = (0...

  5. Spin-glass behavior in the S=1/2 fcc ordered perovskite Sr2CaReO6

    International Nuclear Information System (INIS)

    Wiebe, C.R.; Greedan, J.E.; Luke, G.M.; Gardner, J.S.

    2002-01-01

    The ordered perovskite Sr 2 CaReO 6 of monoclinic symmetry [space group P2 1 /n,a=5.7556(3) A,b=5.8534(3) A,c=8.1317(4) A,β=90.276(5) deg. at T=4 K] has been synthesized using standard solid-state chemistry techniques. The difference in the size and charge of the cations induces an ordering of the B site Ca 2+ and Re 6+ ions which leads to a distorted fcc lattice of spin-(1/2) Re 6+ (5d 1 ) moments. dc magnetic susceptibility measurements indicate a maximum at T G ∼14 K and an irreversibility in the field-cooled and zero-field-cooled data at ∼22 K that is believed to be caused by the geometric frustration inherent in the fcc structure. Neutron-scattering measurements confirm the absence of magnetic long-range order, and muon spin relaxation experiments indicate the presence of an abrupt spin freezing at T G . Specific heat measurements reveal a broad anomaly typical of spin glasses and no sharp feature. 65% of the spin entropy is released at low temperatures. The low-temperature data do not show the expected linear temperature dependence, but rather a T 3 relationship, as is observed, typically, for antiferromagnetic spin waves. The material is characterized as an unconventional, essentially disorder-free, spin glass

  6. Utility of re-windowing for MR T2-weighted images in differentiating between benign tumors and cysts

    International Nuclear Information System (INIS)

    Yamamoto, A.; Nishikawa, K.; Otonari-Yamamoto, M.; Sano, T.

    2009-01-01

    Both benign tumors and cysts in the oral and maxillofacial region show clear borders and homogeneously high signal intensity on magnetic resonance (MR T2-weighted images, making differentiation difficult without contrast enhancement. Windowing for brightness and contrast adjustment may be helpful in interpreting relative signal intensities on MR images. This study was performed to determine whether re-windowing against targeted lesions on T2-weighted images was a useful procedure that would enhance differentiation without invasive contrast enhancement. Twenty-six lesions (13 benign tumors, 13 cysts) that showed clear borders and homogeneously high signal intensity on T2-weighted images were examined. The windowing parameters of axial images were readjusted to emphasize contrast only inside the lesions using automatic density adjustment. Re-windowed images were reviewed by three experienced oral radiologists and categorized based on the internal homogeneity of the lesion into four grades: 0, heterogeneous; 1, slightly heterogeneous; 2, slightly homogeneous; 3, homogeneous. Re-windowing was then evaluated for its usefulness in differentiating between benign tumors and cysts. For cysts, the rates of homogeneous (grades 3 and 2) and heterogeneous intensity (grades 1 and 0) were 66.7 (26/39) and 33.3% (13/39), respectively. For benign tumors, these rates were 33.3 (13/39) and 66.7% (26/39), respectively. Cysts showed a higher rate of homogeneous intensity, while the opposite was true for benign tumors. A significant difference in distribution was observed between cysts and benign tumors (P 2 test). Re-windowing for T2-weighted images is helpful in differentiating between benign tumors and cysts with clear borders and homogeneously high signal intensity on T2-weighted images. (author)

  7. Collinear order in the frustrated spin-(1)/(2) antiferromagnet Li{sub 2}CuW{sub 2}O{sub 8}

    Energy Technology Data Exchange (ETDEWEB)

    Tsirlin, Alexander A. [NICPB, Tallinn (Estonia); Nath, Ramesh; Ranjith, Kumar [Indian Institute of Science Education and Research, Trivandrum (India); Kasinathan, Deepa [MPI CPfS, Dresden (Germany); Skoulatos, Markos [Laboratory of Neutron Scattering, PSI, Villigen (Switzerland)

    2015-07-01

    Li{sub 2}CuW{sub 2}O{sub 8} is a three-dimensional spin-(1)/(2) antiferromagnet that features collinear spin order despite abundant magnetic frustration that would normally trigger a non-collinear incommensurate order, at least on the classical level. Using density-functional calculations, we establish the spin lattice comprising two non-coplanar triangular networks that introduce frustration along all three crystallographic directions. Magnetic susceptibility and heat capacity reveal a 1D-like magnetic response, which is, however, inconsistent with the naive spin-chain model. Moreover, the high saturation field of 29 T compared to the susceptibility maximum at as low as 8.5 K give strong evidence for the importance of interchain couplings and the magnetic frustration. Below T{sub N} ≅ 3.9 K, Li{sub 2}CuW{sub 2}O{sub 8} develops collinear magnetic order with parallel spins along a and c and antiparallel spins along b. The ordered moment is about 0.7 μ{sub B} according to neutron powder diffraction. This qualifies Li{sub 2}CuW{sub 2}O{sub 8} as a unique three-dimensional spin-(1)/(2) antiferromagnet, where collinear magnetic order is stabilized by quantum fluctuations.

  8. Effective S =2 antiferromagnetic spin chain in the salt (o -MePy-V)FeCl4

    Science.gov (United States)

    Iwasaki, Y.; Kida, T.; Hagiwara, M.; Kawakami, T.; Hosokoshi, Y.; Tamekuni, Y.; Yamaguchi, H.

    2018-02-01

    We present a model compound for the S =2 antiferromagnetic (AF) spin chain composed of the salt (o -MePy-V ) FeCl4 . Ab initio molecular-orbital calculations indicate the formation of a partially stacked two-dimensional (2D) spin model comprising five types of exchange interactions between S =1 /2 and S =5 /2 spins, which locate on verdazyl radical and Fe ion, respectively. The magnetic properties of the synthesized crystals indicate that the dominant interaction between the S =1 /2 and S =5 /2 spins stabilizes an S =2 spin in the low-temperature region, and an effective S =2 AF chain is formed for T ≪10 K and H chain. At higher fields above quantitatively 4 T, the magnetization curve assumes two-thirds of the full saturation value for fields between 4 and 20 T, and approaches saturation at ˜40 T. The spin model in the high-field region can be considered as a quasi-2D S =1 /2 honeycomb lattice under an effective internal field caused by the fully polarized S =5 /2 spin.

  9. Value of multiparametric prostate MRI of the peripheral zone

    Energy Technology Data Exchange (ETDEWEB)

    Weidner, Anja M.; Michaely, Henrik J.; Schoenberg, Stefan O.; Dinter, Dietmar J. [University Medical Center Mannheim, Mannheim (Germany). Dept. of Clinical Radiology and Nuclear Medicine; Lemke, Andreas [Heidelberg Univ., Mannheim (Germany). Computer Assisted Clinical Medicine; Breitinger, Lutz [Privatpraxis fuer Urologie Dr. med. Lutz Breitinger, Mannheim (Germany); Wenz, Frederik [University Medical Center Mannheim, Mannheim (Germany). Dept. of Radiation Oncology; Marx, Alexander [University Hospital Mannheim, Mannheim (Germany). Dept. of Pathology

    2011-07-01

    Rationale and Objectives: MRI of the prostate offers the possibility to localize and stage prostate cancer and may improve detection of disease. Currently, T2-weighted images and spectroscopy are the most commonly used MRI techniques. To assess the value of prostate MRI and its different modalities in the process of diagnosis, the currently available MRI techniques were compared. Materials and Methods: 16 patients were examined on a 1.5 T MR system. All patients underwent the same MR protocol using an endorectal coil: T2-weighted triplanar turbo-spin-echo (TSE), axial echo-planar diffusion-weighted imaging (DWI), 3D chemical-shift imaging MR spectroscopy (MRS) and axial dynamic-contrast-enhanced TurboFLASH (DCE). Parametric maps of the choline+creatine/citrate ratio (CC-CR), apparent diffusion coefficient (ADC) and plasma flow/mean transit time (PF/MTT) were calculated. Additionally, average time for reading and scanning were evaluated. As reference, biopsy results were used. Results: Sensitivity/specificity were 50.0-85.7%/44.4-72.2% for the T2 weighted images, 78.6-100.0%/38.9-55.6% for the ADC maps, 71.4-85.7%/44.4-55.6% for the PF/MTT maps and 64.3-78.6%/50.0-77.8% for the CC-CR. Average scan and reading time were 8:46/1:54 min for T2, 1:28/3:17 min for DWI, 8:41/2:12 min for DCE and 11:36/3:47 for spectroscopy. Conclusion: We found no significant differences in accuracy between the modalities. We observed DWI to be advantageous in examination and reading compared to DCE and MRS, therefore it might be the preferred modality when a shortened protocol is needed. (orig.)

  10. Characteristic signal changes in the pontine base on T2- and multishot diffusion-weighted images in spinocerebellar ataxia type 1

    International Nuclear Information System (INIS)

    Adachi, M.; Kawanami, T.; Ohshima, H.; Hosoya, T.

    2006-01-01

    The aim of the present study was to demonstrate characteristic signal changes of the pontine base on T2-weighted images of patients with SCA 1, and to elucidate the relationship between abnormal high-intensities of the pontine base on T2-weighted images and the findings on multishot diffusion-weighted images. We assessed abnormal signals of the pontine base on T2-weighted images from 50 controls and six patients with SCA 1 diagnosed by genetic analysis. At the same time, we evaluated the degeneration of the transverse pontine fibers in the pontine base by multishot diffusion-weighted imaging. A midline high-intensity was seen in the pontine base on T2-weighted images in two of the 50 controls and five of the six patients with SCA 1. The midline high-intensity had a sensitivity of 83.3% for patients and a specificity of 96.0% for controls. Multishot diffusion-weighted imaging demonstrated the degeneration - the amorphous-pattern signal - of the transverse pontine fibers in four (66.7%) of the six patients. In the other two patients, the zebra-pattern signal was seen in the pontine base. The midline high-intensity on T2-weighted images appears to be one of characteristic MRI findings of SCA 1. Multishot diffusion-weighted imaging suggested that the midline high-intensity should reflect the degeneration of the transverse pontine fibers. (orig.)

  11. In vitro of quantitative MR imaging of early degenerative changes in human articular cartilage

    International Nuclear Information System (INIS)

    Kim, Ok Wha; Lee, Young Jun; Cha, Sung Suk; Hwa, Ryu Ji

    2004-01-01

    To assess the applicability of quantitative MR microscopy for the detection of glycosaminoglycan (GAG) depletion as an early sign of degeneration in the articular cartilage of humans treated by trypsin. Four cartilage-bone blocks were obtained from the patient who had suffered from osteoarthritis of the knee and underwent a total knee replacement arthroscopy. Each articular cartilage segment was resected as to a round disk shape (8 mm in diameter) with a remnant of subchondral bone 1 mm in thickness. Four different culture solutions were prepared, and these solutions were 0.2 mg/ml of trypsin solution (group 1), 1 mM of Gd (DTPA) 2-mixed trypsin solution (group 2), phosphate buffered saline (PBS) (group 3), and 1 mM of Gd (DTPA) 2-mixed PBS (group 4). The cartilages were cultured and then MR imagings were performed every hour for 5 hrs, and we continued the additional cultures of 24 hrs, 36 hrs and 48 hrs. Three imaging sequences were used: T1-weighted spin echo (TR/TE, 450/22), proton density turbo spin echo with fat suppression (TR/TE, 3000/25), and CPMG (Carr-Purcell-Meiboom-Gill) (TR/TE/TI, 760/21-168, 360). MR imaging data were analyzed with pixel-by-pixel comparisons in all groups. The GAG loss in the articular cartilage was increased proportionately to the culture duration. Mean changes of T1 relaxation time were 1.2% for group 1, -1.9% for group 3, -54.7% for group 2 and -64.2% for group 4 (p< 0.05). When comparing by linear profile on the T1-weighted images, SNR increased and T1 relaxation time decreased for group 2 and 4, as the culture duration increased (p< 0.05). On the correlation analysis, there is significant correlation between GAG loss and Gd (DTPA) 2-enhancement for group 2 (p=0.0431), but there was no significant difference for group 4 (p=0.0918). More enhancement with Gd (DTPA) 2-was noted for group 2 than for group 4. Group 2 showed a diffuse enhancement in all the layers of cartilage, but for group 4, prominent enhancement was noted only in

  12. Evaluation of T1ρ as a potential MR biomarker for liver cirrhosis: Comparison of healthy control subjects and patients with liver cirrhosis

    International Nuclear Information System (INIS)

    Rauscher, Isabel; Eiber, Matthias; Ganter, Carl; Martirosian, Petros; Safi, Wajima; Umgelter, Andreas; Rummeny, Ernst J.; Holzapfel, Konstantin

    2014-01-01

    Objectives: The purpose of this study was to compare mean liver T 1ρ values in patients with liver cirrhosis and healthy control subjects in order to evaluate T 1ρ as a potential MR biomarker for liver cirrhosis. Materials and methods: Ten healthy control subjects (mean age 42.7 years; 6 female, 4 male) and 21 patients with clinically diagnosed liver cirrhosis (mean age 56.5 years; 5 female, 16 male) were examined at 1.5 T (Magnetom Avanto, Siemens). T 1ρ -weighted images were acquired using a 2D TurboFLASH sequence (TR/TE 3/1.31 ms, FA 8°, FoV 309 × 380 mm, resolution 2 × 2 × 6 mm, acquisition time 15 s, slice thickness 6 mm) with spin-lock preparation. T 1ρ maps were calculated from five breath-hold measurements, performed with different spin-lock times (4, 8, 16, 32 and 48 ms). Mean liver T 1ρ values of healthy control subjects and patients with liver cirrhosis were calculated and compared using Student t-test. In addition, a receiver operating characteristic (ROC) curve analysis was performed to evaluate the utility of mean liver T 1ρ values for the prediction of liver cirrhosis. Results: Mean liver T 1ρ values in patients with liver cirrhosis (57.4 ± 7.4 ms) were significantly higher than those of healthy subjects (47.8 ± 4.2 ms; p = 0.0007). According to the ROC analysis at a threshold value of 50.1 ms the sensitivity and specificity of mean liver T 1ρ in predicting liver cirrhosis were 90.5% and 90%, respectively. The area under the ROC curve was 0.90. Conclusion: Mean liver T 1ρ values in patients with liver cirrhosis were significantly higher than those in healthy subjects suggesting a potential role of liver T 1ρ as a MR biomarker for liver cirrhosis

  13. TU-EF-BRA-02: Longitudinal Proton Spin Relaxation and T1-Imaging

    International Nuclear Information System (INIS)

    Lemen, L.

    2015-01-01

    NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common

  14. TU-EF-BRA-02: Longitudinal Proton Spin Relaxation and T1-Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lemen, L. [Univ Cincinnati (United States)

    2015-06-15

    NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common

  15. Photoinduced Spin Disorder in Half-Metal CrO2 films

    Institute of Scientific and Technical Information of China (English)

    WU Xue-Wei; NIU Dong-Lin; LIU Xiao-Jun

    2006-01-01

    @@ We investigate the photoinduced effects on the spin state for half-metallic ferromagnet CrO2 (TC~390 K), in which the conducting electrons are totally polarized, by means of the time-resolved pump-probe method at the temperature range from 300K to 470K. A significant negative change △T/T for the transmittance spectrum at 1.55eV under photo-excitation is found. The △T/T value monotonically decreases on approaching to TC from the low temperature side, suggesting a photoinduced spin disorder state. Furthermore, we calculate the saturation magnetization MS of CrO2 in both the ground and photo-excited states by using the local-spin-density approximation plus U (LSDA+U) method, and find a decrease of the MS-value in the photo-excited state. The suppressed MS-value in the photo-excited state is consistent with the experimental data.

  16. Dynamic MR imaging of pancreatic cancer

    International Nuclear Information System (INIS)

    Akaki, Shiro; Kohno, Yoshihiro; Gohbara, Hideo

    1994-01-01

    Dynamic MRI was performed on 21 patients with pancreatic duct cell carcinoma. Turbo-FLASH or FLASH3D was performed immediately following rapid bolus injection of gadopentetate dimeglumine, and these FLASH images and conventional spin echo images were evaluated about detectability of the lesion. All images were classified into three groups of detectability of the lesion ; good, fair, and poor. On T 1 weighted image, 23% of cases were 'good' and 48% were evaluated as 'fair'. On the other hand, on dynamic MRI, 62% of cases were 'good' and 33% of cases were evaluated as 'fair'. Both T 2 weighted image and enhanced T 1 weighted image were not useful for depiction of the lesion. Direct comparison between T 1 weighted image and dynamic MRI was also done. In 55% of cases, dynamic MRI was superior to T 1 weighted image and in 40% of cases, dynamic MRI was equal to T 1 weighted image. Thus, dynamic MRI was superior to conventional spin echo images for detection of duct cell carcinoma. In 17 patients of duct cell carcinoma who underwent FLASH3D, contrast/noise ratio (CNR) was calculated before and after injection of gadopentetate dimeglumine. The absolute value of CNR became significantly larger by injection of contrast material. In nine resectable pancreatic carcinomas, two cases of INF α and two cases of medullary type were well depicted. It was concluded that dynamic MRI was useful for evaluation of pancreatic carcinoma. (author)

  17. Diagnostic accuracy of dynamic contrast-enhanced MR imaging of renal masses with rapid-acquisition spin-echo technique

    International Nuclear Information System (INIS)

    Eilenberg, S.S.; Lee, J.K.T.; Brown, J.J.; Heiken, J.P.; Mirowitz, S.A.

    1990-01-01

    This paper compares the diagnostic accuracy of Gd-DTPA-enhanced rapid-acquisition spin-echo (RASE) imaging with standard spin-echo techniques for detecting renal cysts and solid renal neoplasms. RASE imaging combines a short TR (275 msec)/short TE (10 msec), single excitation pulse sequence with half-Fourier data sampling. Eighteen patients with CT evidence of renal masses were first evaluated with standard T1-and T2-weighted SE sequences. Pre- and serial postcontrast (Cd-DTPA, 0.1 mmol./kg) RASE sequences were then performed during suspended respiration. A final set of postcontrast images was obtained with the standard T1-weighted SE sequence. Each set of MR images was first reviewed separately (ie, T1, T2, pre- and post-contrast RASE, etc)

  18. Phase diagrams of a nonequilibrium mixed spin-3/2 and spin-2 Ising system in an oscillating magnetic field

    International Nuclear Information System (INIS)

    Keskin, Mustafa; Polat, Yasin

    2009-01-01

    The phase diagrams of the nonequilibrium mixed spin-3/2 and spin-2 Ising ferrimagnetic system on square lattice under a time-dependent external magnetic field are presented by using the Glauber-type stochastic dynamics. The model system consists of two interpenetrating sublattices of spins σ=3/2 and S=2, and we take only nearest-neighbor interactions between pairs of spins. The system is in contact with a heat bath at absolute temperature T abs and the exchange of energy with the heat bath occurs via one-spin flip of the Glauber dynamics. First, we investigate the time variations of average order parameters to find the phases in the system and then the thermal behavior of the dynamic order parameters to obtain the dynamic phase transition (DPT) points as well as to characterize the nature (first- or second-order) phase transitions. The dynamic phase diagrams are presented in two different planes. Phase diagrams contain paramagnetic (p), ferrimagnetic (i 1 , i 2 , i 3 ) phases, and three coexistence or mixed phase regions, namely i 1 +p, i 2 +p and i 3 +p mixed phases that strongly depend on interaction parameters.

  19. Phase diagrams of a nonequilibrium mixed spin-3/2 and spin-2 Ising system in an oscillating magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Keskin, Mustafa [Department of Physics, Erciyes University, 38039 Kayseri (Turkey)], E-mail: keskin@erciyes.edu.tr; Polat, Yasin [Institutes of Science, Erciyes University, 38039 Kayseri (Turkey)

    2009-12-15

    The phase diagrams of the nonequilibrium mixed spin-3/2 and spin-2 Ising ferrimagnetic system on square lattice under a time-dependent external magnetic field are presented by using the Glauber-type stochastic dynamics. The model system consists of two interpenetrating sublattices of spins {sigma}=3/2 and S=2, and we take only nearest-neighbor interactions between pairs of spins. The system is in contact with a heat bath at absolute temperature T{sub abs} and the exchange of energy with the heat bath occurs via one-spin flip of the Glauber dynamics. First, we investigate the time variations of average order parameters to find the phases in the system and then the thermal behavior of the dynamic order parameters to obtain the dynamic phase transition (DPT) points as well as to characterize the nature (first- or second-order) phase transitions. The dynamic phase diagrams are presented in two different planes. Phase diagrams contain paramagnetic (p), ferrimagnetic (i{sub 1}, i{sub 2}, i{sub 3}) phases, and three coexistence or mixed phase regions, namely i{sub 1}+p, i{sub 2}+p and i{sub 3}+p mixed phases that strongly depend on interaction parameters.

  20. Diagnosis of partial and complete rotator cuff tears using combined gradient echo and spin echo imaging

    International Nuclear Information System (INIS)

    Tuite, M.J.; Yandow, D.R.; DeSmet, A.A.; Orwin, J.F.; Quintana, F.A.

    1994-01-01

    Most magnetic resonance (MR) studies evaluating the rotator cuff for tears have used T2-weighted imaging in the coronal oblique and sagittal oblique planes. T2 * -weighted gradient echo imaging, however, has advantages over spin echo imaging, including contiguous slices without cross-talk, high contrast around the cuff, and intrinsically shorter imaging times which can be used to increase the number of signals averaged and thus improve the signal-to-noise ratio. We reviewed the shoulder MR scans of 87 consecutive patients who underwent both a MR scan and a shoulder arthroscopy during which the size of tears, if present, was graded. The reviewers were blinded as to the history and arthroscopic results. The MR scans included oblique coronal T2 * -weighted gradient echo and oblique sagittal T2-weighted spin echo images. MR cuff grades were correlated with arthroscopic findings. For complete tears, the sensitivity of MR was 0.91 and the specificity 0.95. For partial tears, the sensitivity was 0.74 and the specificity 0.87. This accuracy is similar to two-plane T2-weighted imaging as previously reported in the literature. There was a statistically significant correlation (p < 0.0005) between the cuff grade as determined by MR and the arthroscopic findings. (orig.)

  1. Diagnosis of partial and complete rotator cuff tears using combined gradient echo and spin echo imaging

    Energy Technology Data Exchange (ETDEWEB)

    Tuite, M J [Dept. of Radiology, Univ. of Wisconsin, Madison, WI (United States); Yandow, D R [Dept. of Radiology, Univ. of Wisconsin, Madison, WI (United States); DeSmet, A A [Dept. of Radiology, Univ. of Wisconsin, Madison, WI (United States); Orwin, J F [Div. of Orthopedic Surgery, Univ. of Wisconsin, Madison, WI (United States); Quintana, F A [Dept. of Biostatistics, Univ. of Wisconsin, Madison, WI (United States)

    1994-10-01

    Most magnetic resonance (MR) studies evaluating the rotator cuff for tears have used T2-weighted imaging in the coronal oblique and sagittal oblique planes. T2{sup *}-weighted gradient echo imaging, however, has advantages over spin echo imaging, including contiguous slices without cross-talk, high contrast around the cuff, and intrinsically shorter imaging times which can be used to increase the number of signals averaged and thus improve the signal-to-noise ratio. We reviewed the shoulder MR scans of 87 consecutive patients who underwent both a MR scan and a shoulder arthroscopy during which the size of tears, if present, was graded. The reviewers were blinded as to the history and arthroscopic results. The MR scans included oblique coronal T2{sup *}-weighted gradient echo and oblique sagittal T2-weighted spin echo images. MR cuff grades were correlated with arthroscopic findings. For complete tears, the sensitivity of MR was 0.91 and the specificity 0.95. For partial tears, the sensitivity was 0.74 and the specificity 0.87. This accuracy is similar to two-plane T2-weighted imaging as previously reported in the literature. There was a statistically significant correlation (p < 0.0005) between the cuff grade as determined by MR and the arthroscopic findings. (orig.)

  2. Improving 3D-Turbo Code's BER Performance with a BICM System over Rayleigh Fading Channel

    Directory of Open Access Journals (Sweden)

    R. Yao

    2016-12-01

    Full Text Available Classical Turbo code suffers from high error floor due to its small Minimum Hamming Distance (MHD. Newly-proposed 3D-Turbo code can effectively increase the MHD and achieve a lower error floor by adding a rate-1 post encoder. In 3D-Turbo codes, part of the parity bits from the classical Turbo encoder are further encoded through the post encoder. In this paper, a novel Bit-Interleaved Coded Modulation (BICM system is proposed by combining rotated mapping Quadrature Amplitude Modulation (QAM and 3D-Turbo code to improve the Bit Error Rate (BER performance of 3D-Turbo code over Raleigh fading channel. A key-bit protection scheme and a Two-Dimension (2D iterative soft demodulating-decoding algorithm are developed for the proposed BICM system. Simulation results show that the proposed system can obtain about 0.8-1.0 dB gain at BER of 10^{-6}, compared with the existing BICM system with Gray mapping QAM.

  3. Determination of vitality in myocardial infarction. Comparison of single- and multi-slice MRI techniques with TurboFlash and TrueFISP sequences

    International Nuclear Information System (INIS)

    Huber, A.; Schoenberg, S.O.; Spannagl, B.; Rieber, J.; Klauss, V.; Reiser, M.F.

    2004-01-01

    The aim of the study was to compare the diagnostic accuracy in imaging viability of the myocardium with a multislice inversions recovery 2D single shot TrueFISP sequence and an established inversion recovery TurboFlash sequence. Twelve patients with myocardial infarction were examined at a 1.5 tesla MR system (Sonata, Siemens, Medical Systems) 10 min after application of a single dose multihance (0,1 mmol/kg body weight) with a 2D multislice technique (inversion recovery single shot TrueFISP), that allows to image the entire short axis during one breathhold and a 2D single slice technique (inversion recovery TurboFlash), that requires one breathhold per slice. Signal intensity was determined in normal myocardium, in the infarcted myocardium and in the left ventricle. The contrast/noise ratio of normal and infarcted myocardium was determined. The areas of hyperintense infarction were compared for both sequence techniques. The multislice single shot 2D IR-TrueFisp sequence has a lower contrast/noise ratio than the IR-TurboFlash sequence (mean values 6.9 vs. 12.5) for viable and non viable myocardium. The assessment of the volume of the infarction is possible with excellent correlation of both techniques (r=0.97, p [de

  4. High-speed imaging at 3 tesla. A technical and clinical review with an emphasis on whole-brain 3D imaging

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Kawai, Hisashi; Fukatsu, Hiroshi; Ishigaki, Takeo; Komada, Tomomi

    2005-01-01

    Improvements to the inherently high specific-absorption rate (SAR) of high-speed imaging at 3T are necessary in order to render this method clinically feasible. Various efforts have been undertaken to improve the associated hardware and software. In this review, we focus on whole-brain isotropic 3D imaging with a turbo spin-echo sequence with variable flip-angle echo trains (3D-TSE-VFL) and present its technical and clinical features. This sequence can be used to acquire images of various contrasts including T 2 -weighted, fat-suppressed T 2 -weighted, fluid-attenuated inversion recovery (FLAIR), fat-suppressed FLAIR, and STIR (short tau inversion recovery). Various aspects of 3D-TSE-VFL are discussed, including CSF (cerebrospinal fluid) and metal artifacts, STIR contrast, small-part visualization other than brain, and the possibility of serial subtraction. Some images from clinical cases are presented. (author)

  5. Visual discrimination among patients with depression and schizophrenia and healthy individuals using semiquantitative color-coded fast spin-echo T1-weighted magnetic resonance imaging

    International Nuclear Information System (INIS)

    Sasaki, Makoto; Kudo, Kohsuke; Narumi, Shinsuke; Shibata, Eri; Ohtsuka, Kotaro; Endoh, Jin; Sakai, Akio

    2010-01-01

    Fast spin-echo (FSE) T1-weighted (T1W) magnetic resonance imaging (MRI) at 3T, which is sensitive to neuromelanin-related contrast, can quantitatively detect signal alterations in the locus ceruleus (LC) and the substantia nigra pars compacta (SNc) of depressive and schizophrenic patients; however, its qualitative diagnostic performance remains unknown. We investigated whether visual interpretation of semiquantitative color maps can be used for discriminating between depressive and schizophrenic patients and healthy individuals. We retrospectively examined 23 patients with major depression, 23 patients with schizophrenia, and 23 age-matched healthy controls by using a FSE-T1W MRI technique. Semiquantitative color maps of sections through the LC and SNc were visually interpreted by nine raters using a continuous confidence rating scale for receiver operating characteristic (ROC) analysis. The area under the ROC curve (Az), which reflects the performance in differentiating between depressive patients and controls, was 0.88, and the sensitivity and specificity at the maximum likelihood were 76% and 83%, respectively. In contrast, the Az value, sensitivity, and specificity values between schizophrenics and controls and between depressives and schizophrenics were 0.66 and 0.69, 42% and 48%, and 82% and 84%, respectively. Semiquantitative, color-coded FSE-T1W MRI at 3T can be used for visually differentiating depressive patients from healthy individuals with a substantially high likelihood, but this technique cannot be applied to distinguish schizophrenic patients from the other two groups. (orig.)

  6. Visual discrimination among patients with depression and schizophrenia and healthy individuals using semiquantitative color-coded fast spin-echo T1-weighted magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, Makoto; Kudo, Kohsuke; Narumi, Shinsuke [Iwate Medical University, Advanced Medical Research Center, Morioka (Japan); Shibata, Eri; Ohtsuka, Kotaro; Endoh, Jin; Sakai, Akio [Iwate Medical University, Department of Neuropsychiatry, Morioka (Japan)

    2010-02-15

    Fast spin-echo (FSE) T1-weighted (T1W) magnetic resonance imaging (MRI) at 3T, which is sensitive to neuromelanin-related contrast, can quantitatively detect signal alterations in the locus ceruleus (LC) and the substantia nigra pars compacta (SNc) of depressive and schizophrenic patients; however, its qualitative diagnostic performance remains unknown. We investigated whether visual interpretation of semiquantitative color maps can be used for discriminating between depressive and schizophrenic patients and healthy individuals. We retrospectively examined 23 patients with major depression, 23 patients with schizophrenia, and 23 age-matched healthy controls by using a FSE-T1W MRI technique. Semiquantitative color maps of sections through the LC and SNc were visually interpreted by nine raters using a continuous confidence rating scale for receiver operating characteristic (ROC) analysis. The area under the ROC curve (Az), which reflects the performance in differentiating between depressive patients and controls, was 0.88, and the sensitivity and specificity at the maximum likelihood were 76% and 83%, respectively. In contrast, the Az value, sensitivity, and specificity values between schizophrenics and controls and between depressives and schizophrenics were 0.66 and 0.69, 42% and 48%, and 82% and 84%, respectively. Semiquantitative, color-coded FSE-T1W MRI at 3T can be used for visually differentiating depressive patients from healthy individuals with a substantially high likelihood, but this technique cannot be applied to distinguish schizophrenic patients from the other two groups. (orig.)

  7. Diagnostic value of combined magnetic resonance imaging examination of brachial plexus and electrophysiological studies in multifocal motor neuropathy

    Directory of Open Access Journals (Sweden)

    Basta Ivana

    2014-01-01

    Full Text Available Background/Aim. Multifocal motor neuropathy (MMN is an immune-mediated disorder characterized by slowly progressive asymetrical weakness of limbs without sensory loss. The objective of this study was to investigate the involvement of brachial plexus using combined cervical magnetic stimulation and magnetic resonance imaging (MRI of plexus brachialis in patients with MMN. We payed special attention to the nerve roots forming nerves inervating weak muscles, but without detectable conduction block (CB using conventional nerve conduction studies. Methods. Nine patients with proven MMN were included in the study. In all of them MRI of the cervical spine and brachial plexus was performed using a Siemens Avanto 1.5 T unit, applying T1 and turbo spinecho T1 sequence, axial turbo spin-echo T2 sequence and a coronal fat-saturated turbo spin-echo T2 sequence. Results. In all the patients severe asymmetric distal weakness of muscles inervated by radial, ulnar, median and peroneal nerves was observed and the most striking presentation was bilateral wrist and finger drop. Three of them had additional proximal weakness of muscles inervated by axillar and femoral nerves. The majority of the patients had slightly increased cerebrospinal fluid (CSF protein content. Six of the patients had positive serum polyclonal IgM anti-GM1 antibodies. Electromyoneurography (EMG showed neurogenic changes, the most severe in distal muscles inervated by radial nerves. All the patients had persistent partial CBs outside the usual sites of nerve compression in radial, ulnar, median and peroneal nerves. In three of the patients cervical magnetic stimulation suggested proximal CBs between cervical root emergence and Erb’s point (prolonged motor root conduction time. In all the patients T2-weighted MRI revealed increased signal intensity in at least one cervical root, truncus or fasciculus of brachial plexus. Conclusion. We found clinical correlation between muscle weakness

  8. Urinary bladder cancer T-staging from T2-weighted MR images using an optimal biomarker approach

    Science.gov (United States)

    Wang, Chuang; Udupa, Jayaram K.; Tong, Yubing; Chen, Jerry; Venigalla, Sriram; Odhner, Dewey; Guzzo, Thomas J.; Christodouleas, John; Torigian, Drew A.

    2018-02-01

    Magnetic resonance imaging (MRI) is often used in clinical practice to stage patients with bladder cancer to help plan treatment. However, qualitative assessment of MR images is prone to inaccuracies, adversely affecting patient outcomes. In this paper, T2-weighted MR image-based quantitative features were extracted from the bladder wall in 65 patients with bladder cancer to classify them into two primary tumor (T) stage groups: group 1 - T stage T2, with primary tumor locally confined to the bladder, and group 2 - T stage T2, with primary tumor locally extending beyond the bladder. The bladder was divided into 8 sectors in the axial plane, where each sector has a corresponding reference standard T stage that is based on expert radiology qualitative MR image review and histopathologic results. The performance of the classification for correct assignment of T stage grouping was then evaluated at both the patient level and the sector level. Each bladder sector was divided into 3 shells (inner, middle, and outer), and 15,834 features including intensity features and texture features from local binary pattern and gray-level co-occurrence matrix were extracted from the 3 shells of each sector. An optimal feature set was selected from all features using an optimal biomarker approach. Nine optimal biomarker features were derived based on texture properties from the middle shell, with an area under the ROC curve of AUC value at the sector and patient level of 0.813 and 0.806, respectively.

  9. Detection of hypoxic-ischemic brain injury with 3D-enhanced T2* weighted angiography (ESWAN) imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gang, QiangQiang, E-mail: rousikang@163.com; Zhang, Jianing, E-mail: 1325916060@qq.com; Hao, Peng, E-mail: 1043600590@qq.com; Xu, Yikai, E-mail: yikaivip@163.com

    2013-11-01

    Objective: To demonstrate the use of 3D-enhanced T2* weighted angiography (ESWAN) imaging for the observation and quantification of the evolution of brain injury induced by a recently developed model of hypoxic-ischemic brain injury (HI/R) in neonatal piglets. Methods: For these experiments, newborn piglets were subjected to HI/R injury, during which ESWAN scanning was performed, followed by H and E staining and immunohistochemistry of AQP-4 expression. Results: In the striatum, values from T2* weighted magnetic resonance imaging (MRI) increased and reached their highest level at 3 days post injury, whereas T2* values increased and peaked at 24 h in the subcortical region. The change in T2* values was concordant with brain edema. Phase values in the subcortical border region were not dependent on time post-injury. Magnitude values were significantly different from the control group, and increased gradually over time in the subcortical border region. Susceptibility-weighted images (SWI) indicated small petechial hemorrhages in the striatum and thalamus, as well as dilated intramedullary veins. Conclusion: SWI images can be used to detect white and gray matter microhemorrhages and dilated intramedullary veins. The T2*, phase, and magnitude map can also reflect the development of brain injury. Our data illustrate that ESWAN imaging can increase the diagnostic sensitivity and specificity of MRI in neonatal hypoxic-ischemic encephalopathy.

  10. Detection of hypoxic-ischemic brain injury with 3D-enhanced T2* weighted angiography (ESWAN) imaging

    International Nuclear Information System (INIS)

    Gang, QiangQiang; Zhang, Jianing; Hao, Peng; Xu, Yikai

    2013-01-01

    Objective: To demonstrate the use of 3D-enhanced T2* weighted angiography (ESWAN) imaging for the observation and quantification of the evolution of brain injury induced by a recently developed model of hypoxic-ischemic brain injury (HI/R) in neonatal piglets. Methods: For these experiments, newborn piglets were subjected to HI/R injury, during which ESWAN scanning was performed, followed by H and E staining and immunohistochemistry of AQP-4 expression. Results: In the striatum, values from T2* weighted magnetic resonance imaging (MRI) increased and reached their highest level at 3 days post injury, whereas T2* values increased and peaked at 24 h in the subcortical region. The change in T2* values was concordant with brain edema. Phase values in the subcortical border region were not dependent on time post-injury. Magnitude values were significantly different from the control group, and increased gradually over time in the subcortical border region. Susceptibility-weighted images (SWI) indicated small petechial hemorrhages in the striatum and thalamus, as well as dilated intramedullary veins. Conclusion: SWI images can be used to detect white and gray matter microhemorrhages and dilated intramedullary veins. The T2*, phase, and magnitude map can also reflect the development of brain injury. Our data illustrate that ESWAN imaging can increase the diagnostic sensitivity and specificity of MRI in neonatal hypoxic-ischemic encephalopathy

  11. Comparison of 2D and 3D sequences for MRCP. Clinical value of the different techniques; Vergleich von 2D- und 3D-Sequenzen fuer die MRCP. Klinischer Stellenwert der einzelnen Techniken

    Energy Technology Data Exchange (ETDEWEB)

    Wallnoefer, A.M.; Herrmann, K.A.; Zech, C.J.; Gourtsoyianni, S.; Reiser, M.F.; Schoenberg, S.O. [Klinikum Grosshadern der Ludwig-Maximilian-Universitaet Muenchen (Germany). Institut fuer Klinische Radiologie; Beuers, U. [Klinikum Grosshadern der Ludwig-Maximilian-Universitaet Muenchen (Germany). Klinik fuer Innere Medizin II

    2005-11-01

    Magnetic resonance cholangio-pancreaticograpy (MRCP) is a non-invasive imaging modality of the pancreatico-biliary system which plays an increasingly important role in the clinical and diagnostic workup of patients with biliary or pancreatic diseases. The present review is designed to give an overview of the currently available and appropriate sequences, their technical background, as well as new developments and their relevance to the various clinical issues and challenges. The impact of the latest technical innovations, such as integrated parallel imaging techniques and navigator-based respiratory triggering, on the diagnostic capacities of MRCP is discussed. In this context, the individual value of RARE, T2w single shot turbo/fast spin echo (SSFSE) and the recently introduced 3D T2w turbo/fast spin echo sequences (T2w 3D-T/FSE) is reviewed. RARE imaging may be preferred in severely ill patients with limitations in cooperation, SSFSE is particularly effective in differentiating benign and malignant stenosis, and 3D-FSE offers additional advantages in the detection of small biliary concrements. (orig.) [German] Die Magnetresonanzcholangiopankreatikographie (MRCP) ist eine nichtinvasive Untersuchungsmethode des pankreatikobiliaeren Systems, die heute einen festen Platz in der klinischen Diagnostik eingenommen hat. Die vorliegende Arbeit gibt einen Ueberblick ueber die derzeit gaengigen Sequenzen, ihre technischen Grundlagen sowie ihre jeweilige Bedeutung in den verschiedenen klinischen Einsatzgebieten und Fragestellungen. Darueber hinaus werden die Bedeutung der parallelen Bildgebung, der navigatorbasierten Atemtriggerung und der neu eingefuehrten dreidimensionalen Sequenzen fuer die MRCP sowie ihre moeglichen Einsatzgebiete behandelt. Fuer die MRCP haben die 3 gaengigen Sequenzen, die SS-RARE-Sequenz, die T2w-single-shot-fast-spin-echo- (SSFSE) und die 3D-FSE-Sequenz spezifische Vor- und Nachteile. Die SS-RARE-Sequenz ist aufgrund der sehr kurzen Messzeit bei

  12. Assessment of Myocardial Fibrosis in Mice Using a T2*-Weighted 3D Radial Magnetic Resonance Imaging Sequence.

    Directory of Open Access Journals (Sweden)

    Bastiaan J van Nierop

    Full Text Available Myocardial fibrosis is a common hallmark of many diseases of the heart. Late gadolinium enhanced MRI is a powerful tool to image replacement fibrosis after myocardial infarction (MI. Interstitial fibrosis can be assessed indirectly from an extracellular volume fraction measurement using contrast-enhanced T1 mapping. Detection of short T2* species resulting from fibrotic tissue may provide an attractive non-contrast-enhanced alternative to directly visualize the presence of both replacement and interstitial fibrosis.To goal of this paper was to explore the use of a T2*-weighted radial sequence for the visualization of fibrosis in mouse heart.C57BL/6 mice were studied with MI (n = 20, replacement fibrosis, transverse aortic constriction (TAC (n = 18, diffuse fibrosis, and as control (n = 10. 3D center-out radial T2*-weighted images with varying TE were acquired in vivo and ex vivo (TE = 21 μs-4 ms. Ex vivo T2*-weighted signal decay with TE was analyzed using a 3-component model. Subtraction of short- and long-TE images was used to highlight fibrotic tissue with short T2*. The presence of fibrosis was validated using histology and correlated to MRI findings.Detailed ex vivo T2*-weighted signal analysis revealed a fast (T2*fast, slow (T2*slow and lipid (T2*lipid pool. T2*fast remained essentially constant. Infarct T2*slow decreased significantly, while a moderate decrease was observed in remote tissue in post-MI hearts and in TAC hearts. T2*slow correlated with the presence of diffuse fibrosis in TAC hearts (r = 0.82, P = 0.01. Ex vivo and in vivo subtraction images depicted a positive contrast in the infarct co-localizing with the scar. Infarct volumes from histology and subtraction images linearly correlated (r = 0.94, P<0.001. Region-of-interest analysis in the in vivo post-MI and TAC hearts revealed significant T2* shortening due to fibrosis, in agreement with the ex vivo results. However, in vivo contrast on subtraction images was rather poor

  13. The association between Placental T2* measured by MRI in dichorionic twin pregnancies and intertwin birth weight differences

    DEFF Research Database (Denmark)

    Sørensen, Anne Nødgaard Weidemann; Sinding, Marianne Munk; Peters, David Alberg

    ABSTRACT FINAL ID: P22.06 TITLE: The association between Placental T2* measured by MRI in dichorionic twin pregnancies and intertwin birth weight differences AUTHORS (FIRST NAME, LAST NAME): Anne Sørensen1, 2, Marianne Sinding1, David Peters3, Jens B. Frøkjær4, 2, Astrid Petersen6, Niels Uldbjerg5...... with an increased risk of adverse neonatal outcome, and new methods to predict the intertwin birth weight difference are highly clinical relevant. The Magnetic Resonance Imaging (MRI) variable placentalT2* reflects placental oxygenation and thereby placental function. Therefore, we aimed to investigate...... the association between the intertwin placental T2* difference and the intertwin birth weight difference Methods: A total of 21 dichorionic twin pregnancies (gestational age 20.1 – 34.1 weeks) were included in this study and placental T2* was measured using a gradient recalled echo MRI sequence with readout at 16...

  14. Robust T1-weighted structural brain imaging and morphometry at 7T using MP2RAGE.

    Directory of Open Access Journals (Sweden)

    Kieran R O'Brien

    Full Text Available PURPOSE: To suppress the noise, by sacrificing some of the signal homogeneity for numerical stability, in uniform T1 weighted (T1w images obtained with the magnetization prepared 2 rapid gradient echoes sequence (MP2RAGE and to compare the clinical utility of these robust T1w images against the uniform T1w images. MATERIALS AND METHODS: 8 healthy subjects (29.0 ± 4.1 years; 6 Male, who provided written consent, underwent two scan sessions within a 24 hour period on a 7T head-only scanner. The uniform and robust T1w image volumes were calculated inline on the scanner. Two experienced radiologists qualitatively rated the images for: general image quality; 7T specific artefacts; and, local structure definition. Voxel-based and volume-based morphometry packages were used to compare the segmentation quality between the uniform and robust images. Statistical differences were evaluated by using a positive sided Wilcoxon rank test. RESULTS: The robust image suppresses background noise inside and outside the skull. The inhomogeneity introduced was ranked as mild. The robust image was significantly ranked higher than the uniform image for both observers (observer 1/2, p-value = 0.0006/0.0004. In particular, an improved delineation of the pituitary gland, cerebellar lobes was observed in the robust versus uniform T1w image. The reproducibility of the segmentation results between repeat scans improved (p-value = 0.0004 from an average volumetric difference across structures of ≈ 6.6% to ≈ 2.4% for the uniform image and robust T1w image respectively. CONCLUSIONS: The robust T1w image enables MP2RAGE to produce, clinically familiar T1w images, in addition to T1 maps, which can be readily used in uniform morphometry packages.

  15. BER performance comparison of optical CDMA systems with/without turbo codes

    Science.gov (United States)

    Kulkarni, Muralidhar; Chauhan, Vijender S.; Dutta, Yashpal; Sinha, Ravindra K.

    2002-08-01

    In this paper, we have analyzed and simulated the BER performance of a turbo coded optical code-division multiple-access (TC-OCDMA) system. A performance comparison has been made between uncoded OCDMA and TC-OCDMA systems employing various OCDMA address codes (optical orthogonal codes (OOCs), Generalized Multiwavelength Prime codes (GMWPC's), and Generalized Multiwavelength Reed Solomon code (GMWRSC's)). The BER performance of TC-OCDMA systems has been analyzed and simulated by varying the code weight of address code employed by the system. From the simulation results, it is observed that lower weight address codes can be employed for TC-OCDMA systems that can have the equivalent BER performance of uncoded systems employing higher weight address codes for a fixed number of active users.

  16. 'Turbo' coding for deep space applications

    DEFF Research Database (Denmark)

    Andersen, Jakob Dahl

    1995-01-01

    The performance of the `turbo' coding scheme is measured and an error floor is discovered. These residual errors are corrected with an outer BCH code. The complexity of the system is discussed, and for low data rates a realizable system operating at Eb/N0 below 0.2 dB is presented...

  17. Initial experience with 3D isotropic high-resolution 3 T MR arthrography of the wrist.

    Science.gov (United States)

    Sutherland, John K; Nozaki, Taiki; Kaneko, Yasuhito; J Yu, Hon; Rafijah, Gregory; Hitt, David; Yoshioka, Hiroshi

    2016-01-16

    Our study was performed to evaluate the image quality of 3 T MR wrist arthrograms with attention to ulnar wrist structures, comparing image quality of isotropic 3D proton density fat suppressed turbo spin echo (PDFS TSE) sequence versus standard 2D 3 T sequences as well as comparison with 1.5 T MR arthrograms. Eleven consecutive 3 T MR wrist arthrograms were performed and the following sequences evaluated: 3D isotropic PDFS, repetition time/echo time (TR/TE) 1400/28.3 ms, voxel size 0.35x0.35x0.35 mm, acquisition time 5 min; 2D coronal sequences with slice thickness 2 mm: T1 fat suppressed turbo spin echo (T1FS TSE) (TR/TE 600/20 ms); proton density (PD) TSE (TR/TE 3499/27 ms). A 1.5 T group of 18 studies with standard sequences were evaluated for comparison. All MR imaging followed fluoroscopically guided intra-articular injection of dilute gadolinium contrast. Qualitative assessment related to delineation of anatomic structures between 1.5 T and 3 T MR arthrograms was carried out using Mann-Whitney test and the differences in delineation of anatomic structures among each sequence in 3 T group were analyzed with Wilcoxon signed-rank test. Quantitative assessment of mean relative signal intensity (SI) and relative contrast measurements was performed using Wilcoxon signed-rank test. Mean qualitative scores for 3 T sequences were significantly higher than 1.5 T (p < 0.01), with isotropic 3D PDFS sequence having highest mean qualitative scores (p < 0.05). Quantitative analysis demonstrated no significant difference in relative signal intensity among the 3 T sequences. Significant differences were found in relative contrast between fluid-bone and fluid-fat comparing 3D and 2D PDFS (p < 0.01). 3D isotropic PDFS sequence showed promise in both qualitative and quantitative assessment, suggesting this may be useful for MR wrist arthrograms at 3 T. Primary reasons for diagnostic potential include the ability to make reformations in any

  18. Research on Development of Turbo-generator with Partial Admission Nozzle for Supercritical CO{sub 2} Power Generation

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Junhyun; Shin, Hyung-ki; Lee, Gilbong; Baik, Young-Jin [Korea Institute of Energy Research (KIER), Daejeon (Korea, Republic of); Kang, Young-Seok [Korea Aerospace Research Institute (KARI), Daejeon (Korea, Republic of); Kim, Byunghui [InGineers Ltd., Seoul (Korea, Republic of)

    2017-04-15

    A Sub-kWe small-scale experimental test loop was manufactured to investigate characteristics of the supercritical carbon dioxide power cycle. A high-speed turbo-generator was also designed and manufactured. The designed rotational speed of this turbo-generator was 200,000 rpm. Because of the low expansion ratio through the turbine and low mass flowrate, the rotational speed of the turbo-generator was high. Therefore, it was difficult to select the rotating parts and design the turbine wheel, axial force balance and rotor dynamics in the lab-scale experimental test loop. Using only one channel of the nozzle, the partial admission method was adapted to reduce the rotational speed of the rotor. This was the world’s first approach to the supercritical carbon dioxide turbo-generator. A cold-run test using nitrogen gas under an atmospheric condition was conducted to observe the effect of the partial admission nozzle on the rotor dynamics. The vibration level of the rotor was obtained using a gap sensor, and the results showed that the effect of the partial admission nozzle on the rotor dynamics was allowable.

  19. Image quality and cancer visibility of T2-weighted Magnetic Resonance Imaging of the prostate at 7 Tesla

    NARCIS (Netherlands)

    Vos, E.K.; Lagemaat, M.W.; Barentsz, J.O.; Futterer, J.J.; Zamecnik, P.; Roozen, H.; Orzada, S.; Bitz, A.K.; Maas, M.C.; Scheenen, T.W.J.

    2014-01-01

    To assess the image quality of T2-weighted (T2w) magnetic resonance imaging of the prostate and the visibility of prostate cancer at 7 Tesla (T).Seventeen prostate cancer patients underwent T2w imaging at 7T with only an external transmit/receive array coil. Three radiologists independently scored

  20. Propagation of error from parameter constraints in quantitative MRI: Example application of multiple spin echo T2 mapping.

    Science.gov (United States)

    Lankford, Christopher L; Does, Mark D

    2018-02-01

    Quantitative MRI may require correcting for nuisance parameters which can or must be constrained to independently measured or assumed values. The noise and/or bias in these constraints propagate to fitted parameters. For example, the case of refocusing pulse flip angle constraint in multiple spin echo T 2 mapping is explored. An analytical expression for the mean-squared error of a parameter of interest was derived as a function of the accuracy and precision of an independent estimate of a nuisance parameter. The expression was validated by simulations and then used to evaluate the effects of flip angle (θ) constraint on the accuracy and precision of T⁁2 for a variety of multi-echo T 2 mapping protocols. Constraining θ improved T⁁2 precision when the θ-map signal-to-noise ratio was greater than approximately one-half that of the first spin echo image. For many practical scenarios, constrained fitting was calculated to reduce not just the variance but the full mean-squared error of T⁁2, for bias in θ⁁≲6%. The analytical expression derived in this work can be applied to inform experimental design in quantitative MRI. The example application to T 2 mapping provided specific cases, depending on θ⁁ accuracy and precision, in which θ⁁ measurement and constraint would be beneficial to T⁁2 variance or mean-squared error. Magn Reson Med 79:673-682, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  1. Evaluation of patellar chondromalacia with MR: comparison between T2-weighted FSE SPIR and GE MTC.

    Science.gov (United States)

    Macarini, Luca; Perrone, Alessandra; Murrone, Mario; Marini, Stefania; Stefanelli, Michele

    2004-09-01

    To compare two different MR sequences to tissue signal suppression in the study of patellar cartilage abnormalities. We examined 26 patients with magnetic resonance (MR) imaging: sequences included spectral presaturation with inversion recovery (SPIR), with fat suppression and T2-weighted images, magnetization transfer contrast (MTC) sequences, T1-weighted and T2-weighted spin-echo sequences. All patients underwent conventional knee arthroscopy and in all patients a hyaline cartilage lesion was assessed in three articular zones: the patellar medial facet, the lateral facet and the patellar crista. Was assessed 78 articular facets. The lesions were classified using a standard arthroscopic grading system adapted to MR imaging: normal cartilage that corresponds to the grade 0 according to the Noyes grading system, low grade lesions that correspond to the grade I e IIa and high grade lesions that correspond to grades IIb and III. The arthroscopic results were compared with MR images. We assessed the MR diagnostic accuracy, sensitivity, specificity and MR positive predictive value and negative predictive value of the two sequences taking into consideration total lesions, and high-grade and low grade lesions separately. Twenty-four low grade lesions (16 grade I e 8 grade IIa) and 18 high grade lesions (10 grade IIb e 8 grade III) were diagnosed by arthroscopy. Regarding low grade and high-grade lesions together, the accuracy was 77% for MTC sequences and 90% for SPIR sequences. In identifying low-grade lesions, the sensitivity was 88% for SPIR sequence and 42% for MTC sequences. Specificity for the detection of all lesions was 89% for the SPIR sequences and 94% for the MTC sequences. The SPIR sequence visualised water content abnormalities in degenerating cartilage, which are representative of low-grade lesions. The sensitivity of the sequence enabled us to obtain improved contrast for detecting cartilage surface irregularities. The MTC sequences allowed us to grade high

  2. Designing in-plane heterostructures of quantum spin Hall insulators from first principles: 1T'-MoS2 with adsorbates

    DEFF Research Database (Denmark)

    Olsen, Thomas

    2016-01-01

    opportunity to change the local topology by adsorption of atoms or molecules and thus comprise an ideal platform for designing topological heterostructures. Here we apply first-principles calculations to show that the quantum spin Hall insulator 1T'-MoS2 exhibits a phase transition to a trivial insulator upon....... This is in sharp contrast to topological edge states, which typically exhibit strong dispersion that are sensitive to a particular edge termination. The heterostructure is also suggestive of a simple design of one-dimensional metallic networks in sheets of 1T'-MoS2....

  3. C -P -T anomaly matching in bosonic quantum field theory and spin chains

    Science.gov (United States)

    Sulejmanpasic, Tin; Tanizaki, Yuya

    2018-04-01

    We consider the O (3 ) nonlinear sigma model with the θ term and its linear counterpart in 1+1D. The model has discrete time-reflection and space-reflection symmetries at any θ , and enjoys the periodicity in θ →θ +2 π . At θ =0 ,π it also has a charge-conjugation C symmetry. Gauging the discrete space-time reflection symmetries is interpreted as putting the theory on the nonorientable R P2 manifold, after which the 2 π periodicity of θ and the C symmetry at θ =π are lost. We interpret this observation as a mixed 't Hooft anomaly among charge-conjugation C , parity P , and time-reversal T symmetries when θ =π . Anomaly matching implies that in this case the ground state cannot be trivially gapped, as long as C ,P , and T are all good symmetries of the theory. We make several consistency checks with various semiclassical regimes, and with the exactly solvable XYZ model. We interpret this anomaly as an anomaly of the corresponding spin-half chains with translational symmetry, parity, and time reversal [but not involving the SO(3)-spin symmetry], requiring that the ground state is never trivially gapped, even if SO(3) spin symmetry is explicitly and completely broken. We also consider generalizations to C PN -1 models and show that the C -P -T anomaly exists for even N .

  4. MRI of the cervical spine with 3D gradient echo sequence at 3 T: initial experience

    International Nuclear Information System (INIS)

    Xiao, L.; Siu, C.W.J.; Yeung, K.; Leung, A.; Yuen, M.K.; Wong, Y.C.

    2015-01-01

    Aim: The aim of this study was to compare three-dimensional (3D) high resolution T2*-weighted gradient echo (3D FFE) magnetic resonance (MR) sequence with conventional 2D T2-weighted turbo spin echo (TSE) MR sequence for imaging of the cervical spine, especially to assess the detectability of the internal anatomy of the cervical spinal cord, i.e. to distinguish the grey and white matter. Methods: Fifteen volunteers were examined at 3.0T MR unit. Signal-to-noise (SNR), contrast-to-noise (CNR) and image homogeneity were evaluated. In the visual analysis, the visibility of anatomical structures of the cervical spine and artifacts were assessed. The nonparametric method of paired sample t-test was adopted to evaluate the differences between the sequences. Results: The 3D FFE sequence provided better results for CNR, cerebrospinal fluid (CSF) versus white matter, grey matter, disk and bone. Moreover, it yielded good results for the CNR grey matter versus white matter. The butterfly-shaped “H” is clearly displayed in the 3D FFE sequence. The statistical analysis revealed the statistically significant difference between the 2D TSE and 3D FFE sequences for the contrast of CSF versus spinal cord (both grey matter and white matter). Conclusion: The 3D FFE sequence in MR imaging of the cervical spinal cord is superior in delineation of spinal cord anatomical structures compared to 2D TSE sequence. -- Highlights: •We investigate the potential of 3D FFE sequence to distinguish the grey-white of the cervical spinal cord at 3T MRI system. •We optimized The 3D FFE sequence was optimized to increase the grey-white contrast. •Utilizing medium TE for T2W and the shortest TR for reduction of susceptibility related artifacts and motion artefacts. •This technique may increase the confidence in the diagnosis of disease with the improved delineation of cord anatomy

  5. Structural, thermal and photomagnetic properties of spin crossover [Fe(bpp)2]2+ salts bearing [Cr(L)(ox)2]- anions.

    Science.gov (United States)

    Clemente-León, Miguel; Coronado, Eugenio; Giménez-López, M Carmen; Romero, Francisco M; Asthana, Saket; Desplanches, Cédric; Létard, Jean-François

    2009-10-14

    This paper is divided into two parts: in the first part, the influence of solvate molecules on the magnetic properties of spin crossover salts of [Fe(bpp)(2)][Cr(L)(ox)(2)]ClO(4) x nS (bpp = 2,6-bis(pyrazol-3yl)pyridine; L = 2,2'-bipyridine (bpy) or 1,10-phenanthroline (phen); ox = oxalate dianion; S = solvent) is analyzed. The second part is devoted to the photomagnetic properties of the previously reported [Fe(bpp)(2)][Cr(L)(ox)(2)](2) family of compounds. The study describes the crystal structure, differential scanning calorimetry (DSC) and magnetic properties of [Fe(bpp)(2)][Cr(bpy)(ox)(2)]ClO(4) x EtOH x 4 H(2)O (1) and [Fe(bpp)(2)][Cr(phen)(ox)(2)]ClO(4) x 1.5 EtOH x 4 H(2)O (2). Both salts are high-spin (HS) compounds. Desolvation of 1 yields a material exhibiting a gradual spin crossover that involves 50% of the Fe(2+) cations. Rehydration of this desolvated salt induces a significant increase in the low-spin (LS) population. Desolvation of 2 affords a material showing a more abrupt spin crossover with thermal hysteresis (T(1/2)(increasing) = 286 K and T(1/2)(decreasing) = 273 K). This material is not very sensitive to rehydration. The anhydrous compounds [Fe(bpp)(2)][Cr(bpy)(ox)(2)](2) (3) and [Fe(bpp)(2)][Cr(phen)(ox)(2)](2) (4) display some quantitative photomagnetic conversion with T(LIESST) values of 41 and 51 K, respectively. Kinetic parameters governing the photo-induced HS-LS relaxation process have been determined and used to reproduce the T(LIESST) curves.

  6. Artifact free T2*-weighted imaging at high spatial resolution using segmented EPI sequences

    International Nuclear Information System (INIS)

    Heiler, Patrick Michael; Schad, Lothar Rudi; Schmitter, Sebastian

    2010-01-01

    The aim of this work was the development of novel measurement techniques that acquire high resolution T2 * -weighted datasets in measurement times as short as possible without suffering from noticeable blurring and ghosting artifacts. Therefore, two new measurement techniques were developed that acquire a smoother k-space than generic multi shot echo planar imaging sequences. One is based on the principle of echo train shifting, the other on the reversed gradient method. Simulations and phantom measurements demonstrate that echo train shifting works properly and reduces artifacts in multi shot echo planar imaging. For maximum SNR-efficiency this technique was further improved by adding a second contrast. Both contrasts can be acquired within a prolongation in measurement time by a factor of 1.5, leading to an SNR increase by approximately √2. Furthermore it is demonstrated that the reversed gradient method remarkably reduces artifacts caused by a discontinuous k-space weighting. Assuming sequence parameters as feasible for fMRI experiments, artifact free T2 * -weighted images with a matrix size of 256 x 256 leading to an in-plane resolution in the submillimeter range can be obtained in about 2 s per slice. (orig.)

  7. Preoperative local MRI-staging of patients with a suspected pancreatic mass.

    Science.gov (United States)

    Fischer, U; Vosshenrich, R; Horstmann, O; Becker, H; Salamat, B; Baum, F; Grabbe, E

    2002-02-01

    The aim of this study was to define the value of MRI of the pancreas for preoperative local staging of patients with a suspected pancreatic mass. Ninety-four patients (41 women, 53 men; age range 32-87 years) with a suspected pancreatic tumor underwent preoperative staging with MRI on a 1.5-T system. The MRI protocol included breath-hold MR cholangiopancreatography in turbo spin-echo technique, biphasic contrast-enhanced 3D MR angiography, and MRI of the upper abdomen with breath-hold T2-weighted half-Fourier acquired single-shot turbo spin-echo and T1-weighted fast-low-angle-shot (pre- and postcontrast) sequences. Data were collected prospectively and analyzed by two radiologists in agreement modality. Evaluation criteria were vascular involvement, resectability, and a characterization benign vs malignant. Results were compared to histopathology in 78 patients. Sixteen patients were followed-up. In 74 of 94 patients a solid tumor or an inflammation of the pancreas ( n=62) or the papilla ( n=12) was detected. In this group, MRI had a sensitivity of 98%, a specificity of 92%, and an accuracy of 96% in the characterization of malignant tumors. Regarding only the solid tumors, the positive predictive value of MRI was 87% with respect to resectability. Other pathologic findings included adenoma or inflammation of the duodenum ( n=5), carcinoma or benign stenosis of the choledochus duct ( n=7) and carcinoma of the gall bladder ( n=2). In 6 patients MRI did not depict any pathologic findings, and follow-up confirmed this interpretation. Magnetic resonance imaging allows a local preoperative staging in patients with suspected pancreatic tumor. Limitations, however, concern to the diagnostics of peritoneal and/or liver metastases.

  8. Some problems raised by the operation of large nuclear turbo-generator sets. Automatic control system for steam turbo-generator units

    International Nuclear Information System (INIS)

    Cecconi, F.

    1976-01-01

    The design of an appropriate automatic system was found to be useful to improve the control of large size turbo-generator units so as to provide easy and efficient control and monitoring. The experience of the manufacturer of these turbo-generator units allowed a system well suited for this function to be designed [fr

  9. Value of T2-weighted MR imaging in differentiating low-fat renal angiomyolipomas from other renal tumors

    International Nuclear Information System (INIS)

    Choi, Hyuck Jae; Kim, Jeong Kon; Kim, Mi-Hyun; Cho, Kyoung-Sik; Ahn, Hanjong; Kim, Choung-Soo

    2011-01-01

    Background: Accurate preoperative diagnosis of fat scanty angiomyolipomas is an important clinical issue. By evaluating the low signal intensity of angiomyolipomas in MR T2-weighted images the diagnostic accuracy can be elevated. Purpose: To retrospectively assess the usefulness of T2-weighted MR imaging for differentiating low-fat angiomyolipomas (AMLs) from other renal tumors. Material and Methods: We retrospectively evaluated 71 patients with surgically proven renal masses (10 AMLs, 57 renal cell carcinomas [RCCs], and four oncocytomas), all of which showed no visible fat as well as gradual enhancement patterns on contrast-enhanced CT. Signal intensity was measured in each renal mass and in the spleen on T2-weighted images, and each signal intensity ratio (SIR) was calculated; SIR values were then compared in the AML and non-AML groups. Receiver operating characteristic (ROC) analysis was used to evaluate the diagnostic performance of the two parameters for differentiating the two groups. Results: The SIR values (77 ± 24% vs. 162 ± 79%, p = 0.002) were significantly lower in the AML than in the non-AML group. The area under the ROC curve was 0.926 for SIR. The sensitivity and specificity in the diagnosis of AMLs were 90% and 90.2%, using SIR cut-off of 92.5%. Conclusion: Signal intensity measurements on T2-weighted MR images can differentiate AML from non-AML in the kidney

  10. Spin-echo and STIR MR imaging of sports-related muscle injuries at 1.5 T

    International Nuclear Information System (INIS)

    Greco, A.; McNamara, M.T.; Escher, R.M.B.; Trifilio, G.; Parienti, J.

    1990-01-01

    This paper assesses the value of T2-weighted and short T1 inversion recovery (Stir 1,800,170,27) sequences in the MR diagnosis and follow-up of muscle strain injuries. Fifty-six athletes with clinically diagnosed traumatic muscular damage were studied at 1.5 T with SE T1-weighted, double T2-weighted, and STIR techniques. Images were evaluated in order to detect the presence of muscle tear with associated edema, muscle hemorrhage (focal or diffuse), and perimuscular hemorrhage. The relative conspicuity of muscle injuries on T2-weighted and STIR images was assessed. All acute and subacute muscle injuries were detected on both SE T2-weighted and STIR images, muscle edema and subacute hemorrhage appearing hyperintense to normal muscle. Acute hemorrhage could appear hypointense on T2-weighted images but was always hyperintense on STIR images

  11. Musculoskeletal MRI at 3.0 T and 7.0 T: A comparison of relaxation times and image contrast

    International Nuclear Information System (INIS)

    Jordan, Caroline D.; Saranathan, Manojkumar; Bangerter, Neal K.; Hargreaves, Brian A.; Gold, Garry E.

    2013-01-01

    Objective: The purpose of this study was to measure and compare the relaxation times of musculoskeletal tissues at 3.0 T and 7.0 T, and to use these measurements to select appropriate parameters for musculoskeletal protocols at 7.0 T. Materials and methods: We measured the T 1 and T 2 relaxation times of cartilage, muscle, synovial fluid, bone marrow and subcutaneous fat at both 3.0 T and 7.0 T in the knees of five healthy volunteers. The T 1 relaxation times were measured using a spin-echo inversion recovery sequence with six inversion times. The T 2 relaxation times were measured using a spin-echo sequence with seven echo times. The accuracy of both the T 1 and T 2 measurement techniques was verified in phantoms at both magnetic field strengths. We used the measured relaxation times to help design 7.0 T musculoskeletal protocols that preserve the favorable contrast characteristics of our 3.0 T protocols, while achieving significantly higher resolution at higher SNR efficiency. Results: The T 1 relaxation times in all tissues at 7.0 T were consistently higher than those measured at 3.0 T, while the T 2 relaxation times at 7.0 T were consistently lower than those measured at 3.0 T. The measured relaxation times were used to help develop high resolution 7.0 T protocols that had similar fluid-to-cartilage contrast to that of the standard clinical 3.0 T protocols for the following sequences: proton-density-weighted fast spin-echo (FSE), T 2 -weighted FSE, and 3D-FSE-Cube. Conclusion: The T 1 and T 2 changes were within the expected ranges. Parameters for musculoskeletal protocols at 7.0 T can be optimized based on these values, yielding improved resolution in musculoskeletal imaging with similar contrast to that of standard 3.0 T clinical protocols

  12. NMR studies of spin excitations in superconducting Bi2Sr2CaCu2O8+δ single crystals

    Science.gov (United States)

    Takigawa, M.; Mitzi, D. B.

    1994-08-01

    The oxygen NMR shift and the Cu nuclear spin-lattice relaxation rate (1/T1) were measured in Bi2.1Sr1.9Ca0.9Cu2.1O8+δ single crystals. While both the shift and 1/(T1T) decrease sharply near Tc, 1/(T1T) becomes nearly constant at low temperatures, indicating a gapless superconducting state with finite density of states at the Fermi level. From the oxygen shift data, the residual spin susceptibility at T=0 is estimated to be 10% of the value at room temperature. Our results are most consistent with a d-wave pairing model with strong (resonant) impurity scattering.

  13. Prediction of low birth weight: the placental T2* estimated by MRI versus the uterine artery pulsatility index

    DEFF Research Database (Denmark)

    Sinding, Marianne Munk; Peters, David Alberg; Frøkjær, Jens Brøndum

    (MRI) variable T2* reflects the placental oxygenation and thereby placental function. Therefore, we aimed to evaluate the performance of placental T2* in the prediction of low birth weight using the uterine artery (UtA) pulsatility index (PI) as gold standard. Methods: The study population......CONTROL ID: 2516296 ABSTRACT FINAL ID: P22.05 TITLE: Prediction of low birth weight: the placental T2* estimated by MRI versus the uterine artery pulsatility index AUTHORS (FIRST NAME, LAST NAME): Marianne Sinding1, David Peters2, Jens B. Frøkjær3, 4, Ole B. Christiansen1, 4, Astrid Petersen5...... had an EFW T2* was measured by MRI at 1.5T. A gradient recalled echo MRI sequence with readout at 16 echo times was used, and the placental T2* value was obtained by fitting the signal intensity as a function of the echo times...

  14. Rational examination of the greater abdominal veins with 2D-TOF- and turbo-spin-echo sequences

    International Nuclear Information System (INIS)

    Lutterbey, G.; Sommer, T.; Keller, E.; Kuhl, C.; Schild, H.H.

    1998-01-01

    Purpose: Development of a fast and reliable protocol for the detection and exclusion of abdominal venous thrombosis with an optimised T 2 -TSE- and 2D-TOF sequence. Results: The most effective combination of strong flow-void phenomena, signal/noise ratio and scan time was found with the following parameters: T E 120 ms, T R 2000 ms, 5 mm slice gap. In the patient group two complete and two partial thromboses were diagnosed with both sequences. One wrong positive thrombosis occurred in a stenotic anastomosis with the 2D-inflow sequence. Conclusion: With optimum parameters the T 2 -TSE sequence produces a strong 'flow-void' phenomenon suitable for 'black-blood'-MRA. The use of this sequence alone or in combination with 2D-inflow MRA, if 'bright-blood' MRA is recommended, allows a reliable evaluation of thrombosis in abdominal veins without high-tech MRA equipment and contrast media. (orig./AJ) [de

  15. Forensic age assessment by 3.0T MRI of the knee: proposal of a new MRI classification of ossification stages.

    Science.gov (United States)

    Vieth, Volker; Schulz, Ronald; Heindel, Walter; Pfeiffer, Heidi; Buerke, Boris; Schmeling, Andreas; Ottow, Christian

    2018-03-13

    To explore the possibility of determining majority via a morphology-based examination of the epiphyseal-diaphyseal fusion by 3.0 T magnetic resonance imaging (MRI), a prospective cross-sectional study developing and applying a new stage classification was conducted. 344 male and 350 female volunteers of German nationality between the ages of 12-24 years were scanned between May 2013 and June 2015. A 3.0 T MRI scanner was used, acquiring a T1-weighted (T1-w) turbo spin-echo sequence (TSE) and a T2-weighted (T2-w) TSE sequence with fat suppression by spectral pre-saturation with inversion recovery (SPIR). The gathered information was sifted and a five-stage classification was formulated as a hypothesis. The images were then assessed using this classification. The relevant statistics were defined, the intra- and interobserver agreements were determined, and the differences between the sexes were analysed. The application of the new classification made it possible to correctly assess majority in both sexes by the examination of the epiphyses of the knee joint. The intra- and interobserver agreement levels were very good (κ > 0.80). The Mann-Whitney-U Test implied significant sex-related differences for most stages. Applying the presented MRI classification, it is possible to determine the completion of the 18th year of life in either sex by 3.0 T MRI of the knee joint. • Based on prospective referential data a new MRI classification was formulated. • The setting allows assessment of the age of an individual's skeletal development. • The classification scheme allows the reliable determination of majority in both sexes. • The staging shows a high reproducibility for instructed and trained professional personnel. • The proposed classification is likely to be adaptable to other long bone epiphyses.

  16. Fast spin-echo imaging

    International Nuclear Information System (INIS)

    Mackey, K.; Zoarski, G.; Bentson, J.R.; Lufkin, R.B.; Melki, P.; Jolesz, F.

    1991-01-01

    This paper reports on a partial radio-frequency (RF) echo-planar pulse sequence called contiguous slice fast spin echo (CSFSE) which is undergoing clinical trials for spine MR imaging. In this variation of rapid acquisition relaxation enhanced (RARE) spin-echo imaging, rapid 180 degrees RF pulse generated refocused echoes, producing T2-weighted images in about one-third the time of conventional double-echo technique. Forty patients with suspected pathology of the spine were imaged with conventional double-echo and closely matched CSFSE techniques on a GE Signa 1.5-T Advantage system. Cases were reviewed by two board-certified neuroradiologists. In all cases the CSFSE images were of equal or superior quality compared with those obtained with the conventional double-echo technique. Pathologic processes that were imaged consisted of inflammatory, neoplastic, posttraumatic, and degenerative conditions

  17. The facial nerve in the temporal bone as visualised via thin-layer paratransversal and sagittal MR tomographic images by means of T1 spin-echo and FLASH sequences

    International Nuclear Information System (INIS)

    Mueller-Lisse, U.; Jaeger, L.J.E.; Bruegel, F.J.; Grevers, G.; Reiser, M.F.

    1995-01-01

    It is difficult to effect visualization and delineation of the facial nerve and its neighbouring structures in the temporal bone with conventional MRI examination protocols. We tested temporal bone MRI with 2 mm slices and compared T 1 -weighted FLASH (T R =400 ms, T E =10 ms, 90 flip angle) and spin-echo (T R =540 ms, T E =15 ms) sequences. 5 volunteers and 14 patients were examined with the head coil of a 1.0 T whole body MRI scanner (Impact, Siemens, Erlangen) with para-transversal images orientated parallel to the inferior outline of the clivus and sagittal images orientated along the brainstem. The facial nerve and its neighbouring structures could be reliably visualized and differentiated along its entire course. The FLASH sequence was superior to the spin-echo sequence. 8 of 11 patients with peripheral facial nerve palsy showed contrast enhancement. In two patients, local swelling of the affected facial nerve was evident. (orig./MG) [de

  18. A comparative analysis of double inversion recovery TFE and TSE sequences on carotid artery wall imaging

    International Nuclear Information System (INIS)

    Chen Jun; Di Yujin; Bu Chunqing; Zhang Yanfeng; Li Shuhua

    2012-01-01

    Objective: To analyze the characteristics of double inversion recovery (DIR) turbo field echo (TFE) and turbo spin echo (TSE) sequences and explore the value of double inversion recovery TFE sequence on carotid artery wall imaging. Patients and methods: 56 patients (32 males and 24 females, aged 31–76 years with a mean age of 53 years) were performed with DIR TFE and DIR TSE T1 weighted imaging (T1WI) sequences on carotid artery bifurcations. Image quality acquired by different techniques were evaluated and scored by two physicians. Whether there is significant difference is determined by SPSS 11.0 software. Paired-samples t test was used for statistics. Results: There was no significant difference in the image quality scores between two sequences (t = 0.880, P = 0.383 > 0.05). Conclusions: DIR TFE sequence has short scanning time and high spatial resolution. DIR TFE sequence can be used as the preferred sequence for screening carotid atherosclerotic plaque compared with DIR TSE sequence.

  19. Repeatability of magnetic resonance fingerprinting T1 and T2 estimates assessed using the ISMRM/NIST MRI system phantom.

    Science.gov (United States)

    Jiang, Yun; Ma, Dan; Keenan, Kathryn E; Stupic, Karl F; Gulani, Vikas; Griswold, Mark A

    2017-10-01

    The purpose of this study was to evaluate accuracy and repeatability of T 1 and T 2 estimates of a MR fingerprinting (MRF) method using the ISMRM/NIST MRI system phantom. The ISMRM/NIST MRI system phantom contains multiple compartments with standardized T 1 , T 2 , and proton density values. Conventional inversion-recovery spin echo and spin echo methods were used to characterize the T 1 and T 2 values in the phantom. The phantom was scanned using the MRF-FISP method over 34 consecutive days. The mean T 1 and T 2 values were compared with the values from the spin echo methods. The repeatability was characterized as the coefficient of variation of the measurements over 34 days. T 1 and T 2 values from MRF-FISP over 34 days showed a strong linear correlation with the measurements from the spin echo methods (R 2  = 0.999 for T 1 ; R 2  = 0.996 for T 2 ). The MRF estimates over the wide ranges of T 1 and T 2 values have less than 5% variation, except for the shortest T 2 relaxation times where the method still maintains less than 8% variation. MRF measurements of T 1 and T 2 are highly repeatable over time and across wide ranges of T 1 and T 2 values. Magn Reson Med 78:1452-1457, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  20. Histological evaluation of lung cancer with T2-weighted magnetic resonance images

    International Nuclear Information System (INIS)

    Ohta, Takashi; Matsuura, Yoshifumi; Shioya, Sumie; Ohta, Yasuyo

    1995-01-01

    We investigated the differences in signal intensity of lung cancer tissue and non-cancerous lung tissues on T 2 -weighted magnetic resonance (MR) images. MR images were obtained from patients with squamous cell carcinoma (n=6), adenocarcinoma (n=5), small cell carcinoma (n=5), and large cell carcinoma (n=1). To compare the MR signal intensity between tissues, we calculated the signal intensity ratios for tumor/skeletal muscle and lung/skeletal muscle. The MR signal intensity for each tissue was measured with a densitometer and T 2 -weighted MR images with a similar window and a center. The value of the signal intensity ratio for squamous cell carcinoma (3.26±0.76) was greater than those for adenocarcinoma (1.99±0.50, p<0.05), small cell carcinoma (2.35±0.60), large cell carcinoma (2.46), and non-cancerous lung tissues (1.70±0.68, p<0.02). The values of the MR signal intensity ratio for non-cancerous lung tissues were 2.00 for a collapsed lung, 0.93 for a fibrotic lung, and 2.18 for a fibrotic lung with obstructive pneumonia. The results suggest that the MR signal intensity ratio for pathologic tissues/normal skeletal muscle can be a useful indicator for qualitative and quantitative MR imaging diagnosis. (author)

  1. T2 mapping of articular cartilage of the glenohumeral joint at 3.0 T in healthy volunteers: a feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yusuhn [Seoul National University Bundang Hospital, Department of Radiology, Seongnam-si, Gyeonggi-do (Korea, Republic of); Choi, Jung-Ah [Seoul National University Bundang Hospital, Department of Radiology, Seongnam-si, Gyeonggi-do (Korea, Republic of); Hallym University Dongtan Sacred Heart Hospital, Department of Radiology, Hwaseong, Gyeonggi-do (Korea, Republic of)

    2016-07-15

    The purpose of this study was to assess the T2 values of the glenohumeral joint cartilage in healthy asymptomatic individuals at 3.0 T and to analyze the T2 profile of the humeral cartilage. This prospective study was approved by our institutional review board and written informed consent was obtained. Thirteen subjects (mean age, 28.6 years; age range, 24-33 years) were included and underwent multiecho spin-echo T2-weighted MR imaging and T2 mapping was acquired. Regions of interest were placed on the humeral cartilage and glenoid cartilage on oblique coronal images. T2 profiles of humeral cartilage were measured from the bone-cartilage interface to the articular surface. Intra-observer agreement was analyzed using intraclass correlation coefficient (ICC). All 13 joints showed normal appearance on conventional T2-weighted images. The mean T2 values of humeral and glenoid cartilage were 50.5 ± 12.1 and 49.0 ± 9.9 ms, respectively. Intra-observer agreement was good, as determined by ICC (0.736). Longer T2 values were observed at the articular surface with a tendency to decrease toward the bone-cartilage interface. The mean cartilage T2 value was 69.03 ± 21.2 ms at the articular surface and 46.99 ± 19.6 ms at the bone-cartilage interface. T2 values of the glenohumeral joint cartilage were similar to reported values of cartilage in the knee. The T2 profile of normal humeral cartilage showed a spatial variation with an increase in T2 values from the subchondral bone to the articular surface. (orig.)

  2. Non-contrast magnetic resonance imaging for bladder cancer: fused high b value diffusion-weighted imaging and T2-weighted imaging helps evaluate depth of invasion

    International Nuclear Information System (INIS)

    Lee, Minsu; Oh, Young Taik; Jung, Dae Chul; Park, Sung Yoon; Shin, Su-Jin; Cho, Nam Hoon; Choi, Young Deuk

    2017-01-01

    To investigate the utility of fused high b value diffusion-weighted imaging (DWI) and T2-weighted imaging (T2WI) for evaluating depth of invasion in bladder cancer. We included 62 patients with magnetic resonance imaging (MRI) and surgically confirmed urothelial carcinoma in the urinary bladder. An experienced genitourinary radiologist analysed the depth of invasion (T stage <2 or ≥2) using T2WI, DWI, T2WI plus DWI, and fused DWI and T2WI (fusion MRI). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy were investigated. Area under the curve (AUC) was analysed to identify T stage ≥2. The rate of patients with surgically confirmed T stage ≥2 was 41.9% (26/62). Sensitivity, specificity, PPV, NPV and accuracy were 50.0%, 55.6%, 44.8%, 60.6% and 53.2%, respectively, with T2WI; 57.7%, 77.8%, 65.2%, 71.8% and 69.4%, respectively, with DWI; 65.4%, 80.6%, 70.8%, 76.3% and 74.2%, respectively, with T2WI plus DWI and 80.8%, 77.8%, 72.4%, 84.9% and 79.0%, respectively, with fusion MRI. AUC was 0.528 with T2WI, 0.677 with DWI, 0.730 with T2WI plus DWI and 0.793 with fusion MRI for T stage ≥2. Fused high b value DWI and T2WI may be a promising non-contrast MRI technique for assessing depth of invasion in bladder cancer. (orig.)

  3. Non-contrast magnetic resonance imaging for bladder cancer: fused high b value diffusion-weighted imaging and T2-weighted imaging helps evaluate depth of invasion

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Minsu; Oh, Young Taik; Jung, Dae Chul; Park, Sung Yoon [Yonsei University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Shin, Su-Jin [Yonsei University College of Medicine, Department of Pathology, Seoul (Korea, Republic of); Hanyang University College of Medicine, Department of Pathology, Seoul (Korea, Republic of); Cho, Nam Hoon [Yonsei University College of Medicine, Department of Pathology, Seoul (Korea, Republic of); Choi, Young Deuk [Yonsei University College of Medicine, Department of Urology, Seoul (Korea, Republic of)

    2017-09-15

    To investigate the utility of fused high b value diffusion-weighted imaging (DWI) and T2-weighted imaging (T2WI) for evaluating depth of invasion in bladder cancer. We included 62 patients with magnetic resonance imaging (MRI) and surgically confirmed urothelial carcinoma in the urinary bladder. An experienced genitourinary radiologist analysed the depth of invasion (T stage <2 or ≥2) using T2WI, DWI, T2WI plus DWI, and fused DWI and T2WI (fusion MRI). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy were investigated. Area under the curve (AUC) was analysed to identify T stage ≥2. The rate of patients with surgically confirmed T stage ≥2 was 41.9% (26/62). Sensitivity, specificity, PPV, NPV and accuracy were 50.0%, 55.6%, 44.8%, 60.6% and 53.2%, respectively, with T2WI; 57.7%, 77.8%, 65.2%, 71.8% and 69.4%, respectively, with DWI; 65.4%, 80.6%, 70.8%, 76.3% and 74.2%, respectively, with T2WI plus DWI and 80.8%, 77.8%, 72.4%, 84.9% and 79.0%, respectively, with fusion MRI. AUC was 0.528 with T2WI, 0.677 with DWI, 0.730 with T2WI plus DWI and 0.793 with fusion MRI for T stage ≥2. Fused high b value DWI and T2WI may be a promising non-contrast MRI technique for assessing depth of invasion in bladder cancer. (orig.)

  4. Evidence for power-law spin-correlation decay from muon spin relaxation in AgMn spin-glass

    International Nuclear Information System (INIS)

    MacLaughlin, D.E.; Gupta, L.C.; Cooke, D.W.; Heffner, R.H.; Leon, M.; Schillaci, M.E.

    1983-01-01

    Muon spin relaxation measurements have been carried out below the ''glass'' temperature T/sub g/ in AgMn spin-glasses. The muon spin-lattice relaxation rate varies with field H as H/sup -0.46plus-or-minus0.05/ for 0.30< or =T/T/sub g/< or =0.66. This suggests that impurity-spin correlations decay with time as t/sup -nu/, νapprox. =0.54 +- 0.05, in contrast to the more usual exponential decay. The present data therefore agree quantitatively with the prediction νapprox. =(1/2) of mean-field dynamic theories

  5. Performance test of a ceramic turbo-viscous pump

    International Nuclear Information System (INIS)

    Abe, Tetsuya; Hiroki, Seiji; Murakami, Yoshio; Shiraishi, Shigeyuki; Totoura, Sadayuki; Ohtaki, Takashi.

    1994-01-01

    In the special fields of nuclear fusion facilities and semiconductor production installation, the development of new vacuum pumps which can cope with strong magnetic fields, high temperature gas and corrosive gas is demanded. Mitsubishi Heavy Industries Ltd. has advanced the development of ceramic turbo-molecular pumps and ceramic turbo-viscous pumps, which use ceramic rotors and gas bearings since 1985. The evaluation test of the ceramic turbo-viscous vacuum pump CT-3000H which can evacuate from atmospheric pressure to high vacuum with one pump was carried out, and the experimental results on the performance and the reliability were obtained, therefore, those are reported in this paper. The structure, specification and features of the CT-3000H are shown. The exhaust performance test of the pump was carried out in conformity with the standard of the Vacuum Society of Japan, JVIS 005 'Method of performance test for turbo-molecular pumps'. The gases used were nitrogen and helium. The results are shown. The exhaust test from atmospheric pressure was carried out by two methods, and the results are shown. (K.I.)

  6. Dental MRI using a dedicated RF-coil at 3 Tesla.

    Science.gov (United States)

    Prager, Marcel; Heiland, Sabine; Gareis, Daniel; Hilgenfeld, Tim; Bendszus, Martin; Gaudino, Chiara

    2015-12-01

    To assess the benefit of a dedicated surface coil to visualize dental structures in comparison to standard head/neck coil. Measurements were performed using the standard head/neck coil and a dedicated array coil for dental MRI at 3 T. As MRI methods, we used a T1-weighted spin-echo sequence with and without spectral fat saturation, a T2-weighted turbo-spin-echo sequence and a 3-dimensional T2-weighted SPACE sequence. Measurements were performed in a phantom to examine sensitivity profiles. Then the signal gain in dental structures was examined in volunteers and in a patient. As expected for a surface coil, the signal gain of the dental coil was highest at the surface of the phantom and decreased with increasing distance to the coil; it was >120% even at a depth of 30 mm, measured from the centre of the coil. The signal gain within the pulp of the volunteers ranged between 236 and 413%. The dedicated array coil offers a significantly higher signal within the region of interest for dental MR imaging thus allowing for better depiction of pathologies within the periodontium and for delineation and tracking of the branches of the maxillary and mandibular nerves. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  7. Comparison of peritoneal tumor imaging using conventional MR imaging and diffusion-weighted MR imaging with different b values

    Energy Technology Data Exchange (ETDEWEB)

    Bozkurt, Mahmut [Buhara Private Hospital Department of Radiology, Erzurum (Turkey); Doganay, Selim [Erciyes University, School of Medicine, Department of Radiology, Kayseri (Turkey); Kantarci, Mecit, E-mail: akkanrad@hotmail.com [Atatuerk University, School of Medicine, Department of Radiology, Erzurum (Turkey); Yalcin, Ahmet; Eren, Suat [Atatuerk University, School of Medicine, Department of Radiology, Erzurum (Turkey); Atamanalp, S. Selcuk [Atatuerk University, School of Medicine, Department of General Surgery, Erzurum (Turkey); Yuce, Ihsan [Atatuerk University, School of Medicine, Department of Radiology, Erzurum (Turkey); Yildirgan, M. Ilhan [Atatuerk University, School of Medicine, Department of General Surgery, Erzurum (Turkey)

    2011-11-15

    Purpose: The aim of this study was to evaluate the utility of DW MRI with two different b values in identifying peritoneal tumors in oncology patients. Materials and methods: Nineteen patients with known malignancy underwent abdominal and pelvic MRI before surgery. MRI included free-breathing DWI with b values of 400 and 800 s/mm{sup 2}, T1-weighted fat-suppressed spoiled gradient-echo, T2-weighted fat-saturated turbo spin-echo, and 5-min delayed gadolinium-enhanced imaging. Two observers reviewed images for peritoneal tumors at ten anatomic sites within consensus. The results of laparatomy and histopathological evaluation were compared with MRI results. Sensitivity, specificity, and accuracy of identifying peritoneal metastases were calculated for conventional MRI, combined DWI with a b value of 400 s/mm{sup 2} and conventional MRI, and combined DWI with a b value of 800 s/mm{sup 2} and conventional MRI by consensus of two observers. Results: One-hundred and twenty-five peritoneal metastasis sites were confirmed by surgical and histopathological findings. Conventional MRI alone identified 72 peritoneal metastases (sensitivity, 0.58; specificity, 0.87; accuracy, 0.67). Combined DWI with a b value of 400 s/mm{sup 2} and conventional MRI revealed 106 peritoneal metastases (sensitivity, 0.85; specificity, 0.88; accuracy, 0.85). Finally, combined DWI with a b value of 800 s/mm{sup 2} and conventional MRI revealed 103 peritoneal metastases (sensitivity, 0.83; specificity, 0.94; accuracy, 0.86). Conclusion: DWI with a high b value provides complementary information that can improve the detection of peritoneal tumors when combined with conventional MRI. We recommend combined MRI and DWI with a high b value for increasing the sensitivity and accuracy of the preoperative detection of peritoneal tumors.

  8. Comparison of peritoneal tumor imaging using conventional MR imaging and diffusion-weighted MR imaging with different b values

    International Nuclear Information System (INIS)

    Bozkurt, Mahmut; Doganay, Selim; Kantarci, Mecit; Yalcin, Ahmet; Eren, Suat; Atamanalp, S. Selcuk; Yuce, Ihsan; Yildirgan, M. Ilhan

    2011-01-01

    Purpose: The aim of this study was to evaluate the utility of DW MRI with two different b values in identifying peritoneal tumors in oncology patients. Materials and methods: Nineteen patients with known malignancy underwent abdominal and pelvic MRI before surgery. MRI included free-breathing DWI with b values of 400 and 800 s/mm 2 , T1-weighted fat-suppressed spoiled gradient-echo, T2-weighted fat-saturated turbo spin-echo, and 5-min delayed gadolinium-enhanced imaging. Two observers reviewed images for peritoneal tumors at ten anatomic sites within consensus. The results of laparatomy and histopathological evaluation were compared with MRI results. Sensitivity, specificity, and accuracy of identifying peritoneal metastases were calculated for conventional MRI, combined DWI with a b value of 400 s/mm 2 and conventional MRI, and combined DWI with a b value of 800 s/mm 2 and conventional MRI by consensus of two observers. Results: One-hundred and twenty-five peritoneal metastasis sites were confirmed by surgical and histopathological findings. Conventional MRI alone identified 72 peritoneal metastases (sensitivity, 0.58; specificity, 0.87; accuracy, 0.67). Combined DWI with a b value of 400 s/mm 2 and conventional MRI revealed 106 peritoneal metastases (sensitivity, 0.85; specificity, 0.88; accuracy, 0.85). Finally, combined DWI with a b value of 800 s/mm 2 and conventional MRI revealed 103 peritoneal metastases (sensitivity, 0.83; specificity, 0.94; accuracy, 0.86). Conclusion: DWI with a high b value provides complementary information that can improve the detection of peritoneal tumors when combined with conventional MRI. We recommend combined MRI and DWI with a high b value for increasing the sensitivity and accuracy of the preoperative detection of peritoneal tumors.

  9. Study of two-stage turbine characteristic and its influence on turbo-compound engine performance

    International Nuclear Information System (INIS)

    Zhao, Rongchao; Zhuge, Weilin; Zhang, Yangjun; Yang, Mingyang; Martinez-Botas, Ricardo; Yin, Yong

    2015-01-01

    Highlights: • An analytical model was built to study the interactions between two turbines in series. • The impacts of HP VGT and LP VGT on turbo-compound engine performance were investigated. • The fuel reductions obtained by HP VGT at 1900 rpm and 1000 rpm are 3.08% and 7.83% respectively. • The optimum value of AR ranged from 2.0 to 2.5 as the turbo-compound engine speed decreases. - Abstract: Turbo-compounding is an effective way to recover waste heat from engine exhaust and reduce fuel consumption for internal combustion engine (ICE). The characteristics of two-stage turbine, including turbocharger turbine and power turbine, have significant effects on the overall performance of turbo-compound engine. This paper investigates the interaction between two turbines in a turbo-compound engine and its impact on the engine performance. Firstly an analytical model is built to investigate the effects of turbine equivalent flow area on the two-stage turbine characteristics, including swallowing capacity and load split. Next both simulation and experimental method are carried out to study the effects of high pressure variable geometry turbine (HP VGT), low pressure variable geometry turbine (LP VGT) and combined VGT on the engine overall performance. The results show that the engine performance is more sensitive to HP VGT compared with LP VGT at all the operation conditions, which is caused by the larger influences of HP VGT on the total expansion ratio and engine air–fuel ratio. Using the HP VGT method, the fuel reductions of the turbo-compound engine at 1900 rpm and 1000 rpm are 3.08% and 7.83% respectively, in comparison with the baseline engine. The corresponding optimum values of AR are 2.0 and 2.5

  10. Magnetization transfer on T2-weighted image : magnetization Transfer ratios in normal brain and cerebral lesions

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Myung Kwan; Roh, Hong Gee; Suh, Chang Hae; Cho, Young Kook; Kim, Hyung Jin; Kim, Jin Hee; Kim, Sung Tae; Choi, Sung Kyu [Inha Univ. College of Medicine, Incheon (Korea, Republic of)

    1998-07-01

    To evaluate the magnetization transfer ratio(MTR) of various normal structures and pathologic lesions, as seen on magnetization transfer T2-weighted images (MT+T2WI). Materials and Methods : In ten normal volunteers, T2-weighted images without MT (MT-T2WI) and with MT(MT+T2WI) were obtained. Off-set pulses used in MT+T2WI were 400, 600, 1000, 1500, and 2000Hz. In 60 clinical cases infarction(n=10), brain tumors(n=5), traumatic hematomas(n=5), other hematomas(n=3) vascular malformation(n=2) white matter disease(n=2) normal(n=31) and others(n=2), both MT-T2WI and MT+T2WI images were obtained using an off-set pulse of 600 Hz. In all volunteers and patients, MTR in various normal brain parenchyma and abnormal areas was measured. Results : The MTRs of white and gray matter were 48% and 45% respectively at 400 Hz, 26% and 22% at 600Hz, 12% and 11% of 1000Hz, 10% and 9% 1500HZ, and 9% and 8% at 2000Hz of RF. The MTR of CSF was 43% at 400 Hz of off-resonance RF, while the contrast resolution of T2WI was poor. An off-resonance of 600Hz appeared to be the optimal frequency. In diseased areas,MTRs varied but were usually similar to or lower than those of brain parenchyma. Conclusion : The optimal off-resonance RF on MT+T2WI appears to be 600 Hz for relatively high MTR of brain parenchyma and low MTR of CSF,in which MTRs of white and gray matter were 26% and 22%, respectively, of 600Hz off-set pulse. The MTRs of cerebral lesions varied and further studies of various cerebral lesions are needed.

  11. T2[sup *] weighted MR imaging for the diagnosis of the perforation of triangular fibrocartilage; Comparison with arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Taro; Nakamura, Eiziro; Ahsoh, Kuniichi; Masumi, Shogo (Oita Medical Univ., Takatsuki (Japan))

    1994-05-01

    Perforation of the triangular fibrocartilage (TFC) has been considered an important factor in the etiology of pain in the ulnar wrist joint, and arthrography has been used conventionally to diagnose the perforation. Recently, magnetic resonance imaging (MRI) has been used to diagnose TFC perforation. Gundy et al. examined cadaver wrists with Tl weighted imaging and arthrography, and obtained findings suggesting that arthrography provides a more accurate diagnosis of the TFC perforation. To our knowledge, no comparison has yet been made between T2[sup *] weighted imaging and arthrography in the diagnosis of TFC perforation. The present study compared the usefulness of T2[sup *]-weighted imaging and arthrography in the diagnosis of TFC perforation in 22 wrist joints of 11 cadavers (5 males and 6 females with ages ranging from 61 to 92 years and an average age of 78.8 years) fixed in 60% formalin. The specimens were firstly analyzed by a T2[sup *]-weighted 0.5T MRI scan and subsequently by arthrography. After diagnosing the image obtained by the two methods, the accuracy of the diagnosis was determined by comparison with the macroscopic findings of autopsy, including the presence and degree of TFC perforation. A T2[sup *]-weighted MRI scan of the TFC perforation showed high-intensity areas over the distal radio-ulnar joint, and demonstrated the same diagnostic accuracy as arthrography, providing correct diagnoses in all cases other than linear perforation. However, neither of the image diagnostic methods allowed definition of the type of perforation. (author).

  12. A Theoretical Framework for Soft-Information-Based Synchronization in Iterative (Turbo Receivers

    Directory of Open Access Journals (Sweden)

    Lottici Vincenzo

    2005-01-01

    Full Text Available This contribution considers turbo synchronization, that is to say, the use of soft data information to estimate parameters like carrier phase, frequency, or timing offsets of a modulated signal within an iterative data demodulator. In turbo synchronization, the receiver exploits the soft decisions computed at each turbo decoding iteration to provide a reliable estimate of some signal parameters. The aim of our paper is to show that such "turbo-estimation" approach can be regarded as a special case of the expectation-maximization (EM algorithm. This leads to a general theoretical framework for turbo synchronization that allows to derive parameter estimation procedures for carrier phase and frequency offset, as well as for timing offset and signal amplitude. The proposed mathematical framework is illustrated by simulation results reported for the particular case of carrier phase and frequency offsets estimation of a turbo-coded 16-QAM signal.

  13. Isolated neurosarcoidosis - MR findings and pathologic correlation. A case report

    Energy Technology Data Exchange (ETDEWEB)

    Bode, M.K.; Tikkakoski, T.; Tuisku, S.; Kronqvist, E. [Keski-Pohjanmaa Central Hospital, Kokkola (Finland); Tuominen, H. [Oulu Univ. Hospital (Finland). Dept. of Pathology

    2001-11-01

    Neurosarcoidosis is a diagnostic challenge, especially if systemic symptoms are absent. We present a 49-year-old woman with isolated neurosarcoidosis. The main symptom was loss of vision in the left eye. Brain MR imaging showed 6 high-signal white matter lesions frontotemporally on proton density and T2-weighted turbo spin-echo images. Coronal fat-saturated turbo FLAIR images of the orbits showed a swollen left optic nerve with increased signal intensity, which finding has not been previously published in sarcoid optic neuropathy. A control MR examination showed meningeal enhancement of the left optic nerve and leptomeningeal enhancing lesions around the brain stem. Spinal MR revealed leptomeningeal enhancement throughout the spinal cord and asymptomatic enhancing cauda equina lesions, mimicking subarachnoid tumour seeding, and an enhancing nerve root mass at Th12/L1. Biopsy of the latter lesion revealed non-caseating granulomas consistent with sarcoidosis.

  14. Isolated neurosarcoidosis - MR findings and pathologic correlation. A case report

    International Nuclear Information System (INIS)

    Bode, M.K.; Tikkakoski, T.; Tuisku, S.; Kronqvist, E.; Tuominen, H.

    2001-01-01

    Neurosarcoidosis is a diagnostic challenge, especially if systemic symptoms are absent. We present a 49-year-old woman with isolated neurosarcoidosis. The main symptom was loss of vision in the left eye. Brain MR imaging showed 6 high-signal white matter lesions frontotemporally on proton density and T2-weighted turbo spin-echo images. Coronal fat-saturated turbo FLAIR images of the orbits showed a swollen left optic nerve with increased signal intensity, which finding has not been previously published in sarcoid optic neuropathy. A control MR examination showed meningeal enhancement of the left optic nerve and leptomeningeal enhancing lesions around the brain stem. Spinal MR revealed leptomeningeal enhancement throughout the spinal cord and asymptomatic enhancing cauda equina lesions, mimicking subarachnoid tumour seeding, and an enhancing nerve root mass at Th12/L1. Biopsy of the latter lesion revealed non-caseating granulomas consistent with sarcoidosis

  15. TurboTech Technical Evaluation Automated System

    Science.gov (United States)

    Tiffany, Dorothy J.

    2009-01-01

    TurboTech software is a Web-based process that simplifies and semiautomates technical evaluation of NASA proposals for Contracting Officer's Technical Representatives (COTRs). At the time of this reporting, there have been no set standards or systems for training new COTRs in technical evaluations. This new process provides boilerplate text in response to interview style questions. This text is collected into a Microsoft Word document that can then be further edited to conform to specific cases. By providing technical language and a structured format, TurboTech allows the COTRs to concentrate more on the actual evaluation, and less on deciding what language would be most appropriate. Since the actual word choice is one of the more time-consuming parts of a COTRs job, this process should allow for an increase in quantity of proposals evaluated. TurboTech is applicable to composing technical evaluations of contractor proposals, task and delivery orders, change order modifications, requests for proposals, new work modifications, task assignments, as well as any changes to existing contracts.

  16. 3 T MRI of hepatocellular carcinomas in patients with cirrhosis: Does T2-weighted imaging provide added value?

    International Nuclear Information System (INIS)

    Guo, L.; Liang, C.; Yu, T.; Wang, G.; Li, N.; Sun, H.; Gao, F.; Liu, C.

    2012-01-01

    Aim: To assess whether T2-weighted imaging (T2WI) provides any added value for the detection of hepatocellular carcinoma (HCC) in patients with cirrhosis, especially for lesions smaller than 2 cm. Materials and methods: Sixty-five patients with cirrhosis underwent liver 3 T MRI. Images were qualitatively analysed independently by two observers in two separate sessions, including a dynamic enhanced session and a combination of dynamic and T2WI. The diagnostic accuracy was evaluated using the alternating free-response receiver operating characteristic. Sensitivity and positive predictive values were calculated for all HCCs and for the subgroup of HCCs that were smaller than 2 cm. Additionally, artefacts on T2WI were evaluated by two observers in consensus. Results: Ninety HCCs (>2 cm n = 36; ≤2 cm n = 54) were detected in 46 patients. For all HCCs and for lesions smaller than 2 cm, the sensitivities were significantly higher for the combined session than the dynamic session alone (p < 0.05). Conversely, for the Az and positive predictive values, there was no significant difference between the two sessions. For smaller HCC, 9% (5/54) and 7% (4/54) of the 54 HCCs were correctly interpreted by observers 1 and 2, respectively, only when T2WI was included. Three false-positive lesions (≤2 cm) were correctly diagnosed by one of the observers after combining T2WI. Conspicuity of only one large HCC was severely reduced by the artefacts from massive ascites. Conclusion: At 3 T liver imaging, combining with T2WI can improve the sensitivity of detection of HCC compared with dynamic MRI alone by increasing observer confidence, especially for lesions smaller than 2 cm. Additionally, T2 image quality was not significantly affected by artefacts.

  17. 3 T MRI of hepatocellular carcinomas in patients with cirrhosis: Does T2-weighted imaging provide added value?

    Energy Technology Data Exchange (ETDEWEB)

    Guo, L.; Liang, C.; Yu, T.; Wang, G.; Li, N.; Sun, H.; Gao, F. [Shandong Medical Imaging Research Institute, Shandong University, Jinan (China); Liu, C., E-mail: liucheng1025@163.com [Shandong Medical Imaging Research Institute, Shandong University, Jinan (China)

    2012-04-15

    Aim: To assess whether T2-weighted imaging (T2WI) provides any added value for the detection of hepatocellular carcinoma (HCC) in patients with cirrhosis, especially for lesions smaller than 2 cm. Materials and methods: Sixty-five patients with cirrhosis underwent liver 3 T MRI. Images were qualitatively analysed independently by two observers in two separate sessions, including a dynamic enhanced session and a combination of dynamic and T2WI. The diagnostic accuracy was evaluated using the alternating free-response receiver operating characteristic. Sensitivity and positive predictive values were calculated for all HCCs and for the subgroup of HCCs that were smaller than 2 cm. Additionally, artefacts on T2WI were evaluated by two observers in consensus. Results: Ninety HCCs (>2 cm n = 36; {<=}2 cm n = 54) were detected in 46 patients. For all HCCs and for lesions smaller than 2 cm, the sensitivities were significantly higher for the combined session than the dynamic session alone (p < 0.05). Conversely, for the Az and positive predictive values, there was no significant difference between the two sessions. For smaller HCC, 9% (5/54) and 7% (4/54) of the 54 HCCs were correctly interpreted by observers 1 and 2, respectively, only when T2WI was included. Three false-positive lesions ({<=}2 cm) were correctly diagnosed by one of the observers after combining T2WI. Conspicuity of only one large HCC was severely reduced by the artefacts from massive ascites. Conclusion: At 3 T liver imaging, combining with T2WI can improve the sensitivity of detection of HCC compared with dynamic MRI alone by increasing observer confidence, especially for lesions smaller than 2 cm. Additionally, T2 image quality was not significantly affected by artefacts.

  18. MRI findings of radiation encephalopathy of brain stem after radiotherapy for nasopharyngeal cancer

    International Nuclear Information System (INIS)

    Liang Changhong; Li Guoye; Huang Biao; Huang Meiping; Zheng Junhui; Tan Shaoheng; Zeng Qiongxin

    1998-01-01

    Purpose: To study MRI findings and clinical manifestation of radiation encephalopathy (RE) of brain stem. Methods: MRI findings and clinical symptoms in 51 patients with RE of brain stem after radiotherapy for nasopharyngeal cancer were reviewed. Results: Clinical symptoms included number weakness or paralysis in the limbs and symptoms of damaged cranial nerves. All lesions appeared hypo- or iso-intense on spin echo(SE) T 1 -weighted images and inhomogeneous and mixed hyper- and iso-intense on Turbo spin echo (TSE) T 2 -weighted images. The lesions were located in mesencephalon, pons, medulla, basilar part of pons, basilar part of pons and medulla oblongata in 2,7,3,9 and 30 patients respectively. The enhancement patterns included irregular rings in 39 patients, spotty in 3 and no enhancement in 9 patients. Mass effect was minimal in all patients. On follow-up MRI, the lesions disappeared in 4 patients, did not change in size and shape in 8 patients and enlarged in 2 patients. Conclusion: MRI could demonstrate the characteristic findings of RE of brain stem. MRI findings sometimes are not consistent with the clinical symptoms

  19. Three-dimensional susceptibility-weighted imaging and two-dimensional T2*-weighted gradient-echo imaging of intratumoral hemorrhages in pediatric diffuse intrinsic pontine glioma

    International Nuclear Information System (INIS)

    Loebel, Ulrike; Sedlacik, Jan; Sabin, Noah D.; Hillenbrand, Claudia M.; Patay, Zoltan; Kocak, Mehmet; Broniscer, Alberto

    2010-01-01

    We compared the sensitivity and specificity of T2*-weighted gradient-echo imaging (T2*-GRE) and susceptibility-weighted imaging (SWI) in determining prevalence and cumulative incidence of intratumoral hemorrhages in children with diffuse intrinsic pontine glioma (DIPG) undergoing antiangiogenic and radiation therapy. Patients were recruited from an institutional review board-approved prospective phase I trial of vandetanib administered in combination with radiation therapy. Patient consent was obtained before enrollment. Consecutive T2*-GRE and SWI exams of 17 patients (F/M: 9/8; age 3-17 years) were evaluated. Two reviewers (R1 and R2) determined the number and size of hemorrhages at baseline and multiple follow-ups (92 scans, mean 5.4/patient). Statistical analyses were performed using descriptive statistics, graphical tools, and mixed-effects Poisson regression models. Prevalence of hemorrhages at diagnosis was 41% and 47%; the cumulative incidences of hemorrhages at 6 months by T2*-GRE and SWI were 82% and 88%, respectively. Hemorrhages were mostly petechial; 9.7% of lesions on T2*-GRE and 5.2% on SWI were hematomas (>5 mm). SWI identified significantly more hemorrhages than T2*-GRE did. Lesions were missed or misinterpreted in 36/39 (R1/R2) scans by T2*-GRE and 9/3 scans (R1/R2) by SWI. Hemorrhages had no clinically significant neurological correlates in patients. SWI is more sensitive than T2*-GRE in detecting hemorrhages and differentiating them from calcification, necrosis, and artifacts. Also, petechial hemorrhages are more common in DIPG at diagnosis than previously believed and their number increases during the course of treatment; hematomas are rare. (orig.)

  20. Proton T2 Relaxation effect of superparamagnetic iron oxide on fast spin echo sequence. Influence of echo number (even or odd) of effective TE

    International Nuclear Information System (INIS)

    Tsuchihashi, Toshio; Maki, Toshio; Kitagawa, Matsuo; Suzuki, Takeshi; Fujita, Isao

    1999-01-01

    The T 2 relaxation effect of the fast spin echo sequence (FSE) was investigated using superparamagnetic iron oxide (SPIO) particles. When even echoes were used as the effective TE of FSE, the signal intensity ratio [signal intensity of FSE/signal intensity of conventional spin echo sequence (CSE)] of FSE and CSE increased, whereas the T 2 relaxation effect of SPIO with FSE was reduced. However, when odd echoes were used, neither signal intensity changed, and weakening of the T 2 relaxation effect, considered a problem with FSE, was reduced. This phenomenon was not observed when the refocusing flip angle was changed to 30 and 60 degrees. However, it was observed when the refocusing flip angle was 120 and 150 degrees. Thus, this phenomenon can be considered to be related to oscillation in longitudinal magnetization when using the Carr-Purcell-Meiboom-Gill (CPMG) technique. (author)

  1. Comparison of a T1-weighted inversion-recovery-, gradient-echo- and spin-echo sequence for imaging of the brain at 3.0 Tesla

    International Nuclear Information System (INIS)

    Stehling, C.; Niederstadt, T.; Kraemer, S.; Kugel, H.; Schwindt, W.; Heindel, W.; Bachmann, R.

    2005-01-01

    Purpose: The increased T1 relaxation times at 3.0 Tesla lead to a reduced T1 contrast, requiring adaptation of imaging protocols for high magnetic fields. This prospective study assesses the performance of three techniques for T1-weighted imaging (T1w) at 3.0 T with regard to gray-white differentiation and contrast-to-noise-ratio (CNR). Materials and Methods: Thirty-one patients were examined at a 3.0 T system with axial T1 w inversion recovery (IR), spin-echo (SE) and gradient echo (GE) sequences and after contrast enhancement (CE) with CE-SE and CE-GE sequences. For qualitative analysis, the images were ranked with regard to artifacts, gray-white differentiation, image noise and overall diagnostic quality. For quantitative analysis, the CNR was calculated, and cortex and basal ganglia were compared with the white matter. Results: In the qualitative analysis, IR was judged superior to SE and GE for gray-white differentiation, image noise and overall diagnostic quality, but inferior to the GE sequence with regard to artifacts. CE-GE proved superior to CE-SE in all categories. In the quantitative analysis, CNR of the based ganglia was highest for IR, followed by GE and SE. For the CNR of the cortex, no significant difference was found between IR (16.9) and GE (15.4) but both were superior to the SE (9.4). The CNR of the cortex was significantly higher for CE-GE compared to CE-SE (12.7 vs. 7.6, p<0.001), but the CNR of the basal ganglia was not significantly different. Conclusion: For unenhanced T1w imaging at 3.0 T, the IR technique is, despite increased artifacts, the method of choice due to its superior gray-white differentiation and best overall image quality. For CE-studies, GE sequences are recommended. For cerebral imaging, SE sequences give unsatisfactory results at 3.0 T. (orig.)

  2. Leak detection in turbo group condensers using helium

    International Nuclear Information System (INIS)

    Gomez Cores, C.; Lloret, J.

    1997-01-01

    This method allows a rapid location of leaks (small or not) in the pipelines of a turbo group condenser, before opening the condenser boxes and no need of stooping the turbo group operation. This operation can last two hours maximum depending on the volume of the box or semi box. The technique consists of injecting helium into the water side and detecting it in the steam side, in the outlet of not condensable gases of the ejector. In the same way, probable air inlet to the condenser can be proved (auxiliary systems, turbo group joints to the condenser, etc.) in order to improve the vacuum and/or reduce the quantity of oxygen dissolved in the water of the steam side. (author) [es

  3. Hydrogen-bonded networks of [Fe(bpp)2]2+ spin crossover complexes and dicarboxylate anions: structural and photomagnetic properties.

    Science.gov (United States)

    Jornet-Mollá, Verónica; Duan, Yan; Giménez-Saiz, Carlos; Waerenborgh, João C; Romero, Francisco M

    2016-11-28

    The paper reports the syntheses, crystal structures, thermal and (photo)magnetic properties of spin crossover salts of formula [Fe(bpp) 2 ](C 6 H 8 O 4 )·4H 2 O (1·4H 2 O), [Fe(bpp) 2 ](C 8 H 4 O 4 )·2CH 3 OH·H 2 O (2·2MeOH·H 2 O) and [Fe(bpp) 2 ](C 8 H 4 O 4 )·5H 2 O (2·5H 2 O) (bpp = 2,6-bis(pyrazol-3yl)pyridine; C 6 H 8 O 4 = adipate dianion; C 8 H 4 O 4 = terephthalate dianion). The salts exhibit an intricate network of hydrogen bonds between low-spin iron(ii) complexes and carboxylate dianions, with solvent molecules sitting in the voids. Desolvation is accompanied by a low-spin (LS) to high-spin (HS) transformation in the materials. The dehydrated phase 2 undergoes a two-step transition with a second step showing thermal hysteresis (T 1/2 ↑ = 139 K and T 1/2 ↓ = 118 K). 2 displays a quantitative LS to HS photomagnetic conversion, with a T(LIESST) value of 63 K.

  4. Spin correlation in t anti t production from p anti p collisions at √s = 1.8 TeV

    International Nuclear Information System (INIS)

    Suyong Choi

    2000-01-01

    The Standard Model predicts that the lifetime of the top quark is shorter than the typical time scale at which hadronization process occurs, and the spin information at its production is preserved. Spin correlation of the t anti t system from p anti p collisions at the Tevatron is analyzed using 6 events in the dilepton channels collected using the D0 detector. Spin correlation factor of κ > minus 0.25 at 68% CL is obtained from the data

  5. Diffusion-weighted single shot echo planar imaging of colorectal cancer using a sensitivity-encoding technique

    International Nuclear Information System (INIS)

    Nasu, Katsuhiro; Kuroki, Yoshihumi; Murakami, Koji; Nawano, Shigeru; Kuroki, Seiko; Moriyama, Noriyuki

    2004-01-01

    We wanted to determine the feasibility of diffusion-weighted single shot echo planar imaging using a sensitivity encoding diffusion weighted imaging (SENSE-DWI) technique in depicting colorectal cancer. Forty-two patients with sigmoid colon cancer and rectal cancer, all proven pathologically, were examined on T2-turbo spin echo (TSE) and SENSE-DWI. No bowel preparation was performed before examination. The b-factors used in SENSE-DWI were zero and 1000 s/mm 2 . In 10 randomly selected cases, the images whose b-factors were 250 and 500 s/mm 2 were also obtained. The reduction factor of SENSE was 2.0 in all sequences. Two radiologists evaluated the obtained images from the viewpoints of tumor detectability, image distortion and misregistration of the tumors. The apparent diffusion coefficients (ADCs) of the tumors and urine in the urinary bladders in each patient were measured to evaluate the correlation between ADC and pathological classification of each tumor. All tumors were depicted hyperintensely on SENSE-DWI. Even though single shot echo planar imaging (EPI) was used, the image distortion and misregistration was quite pronounced because of simultaneous use of SENSE. On SENSE-DWI whose b-factor was 1000 s/mm 2 , the normal colon wall and feces were always hypointense and easily differentiated from the tumors. The mean ADC value of each tumor was 1.02±0.1 (x 10 -3 ) mm 2 /s. No overt correlation can be pointed out between ADC and pathological classification of each tumor. SENSE-DWI is a feasible method for depicting colorectal cancer. SENSE-DWI provides strong contrast among colorectal cancers, normal rectal wall and feces. (authors)

  6. SU-E-J-217: Multiparametric MR Imaging of Cranial Tumors On a Dedicated 1.0T MR Simulator Prior to Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Wen, N; Glide-Hurst, C; Liu, M; Hearshen, D; Brown, S; Siddiqui, S; Chetty, I [Henry Ford Health System, Detroit, MI (United States)

    2015-06-15

    Purpose: Quantitative magnetic resonance imaging (MRI) of cranial lesions prior to stereotactic radiosurgery (SRS) may improve treatment planning and provide potential prognostic value. The practicality and logistics of acquiring advanced multiparametric MRI sequences to measure vascular and cellular properties of cerebral tumors are explored on a 1.0 Tesla MR Simulator. Methods: MR simulation was performed immediately following routine CT simulation on a 1T MR Simulator. MR sequences used were in the order they were performed: T2-Weighted Turbo Spin Echo (T2W-TSE), T2 FLAIR, Diffusion-weighted (DWI, b = 0, 800 to generate an apparent diffusion coefficient (ADC) map), 3D T1-Weighted Fast Field Echo (T1W-FFE), Dynamic Contrast Enhanced (DCE) and Post Gadolinium Contrast Enhanced 3D T1W-FFE images. T1 pre-contrast values was generated by acquiring six different flip angles. The arterial input function was derived from arterial pixels in the perfusion images selected manually. The extended Tofts model was used to generate the permeability maps. Routine MRI scans took about 30 minutes to complete; the additional scans added 12 minutes. Results: To date, seven patients with cerebral tumors have been imaged and tumor physiology characterized. For example, on a glioblastoma patient, the volume contoured on T1 Gd images, ADC map and the pharmacokinetic map (Ktrans) were 1.9, 1.4, and 1.5 cc respectively with strong spatial correlation. The mean ADC value of the entire volume was 1141 μm2/s while the value in the white matter was 811 μm2/s. The mean value of Ktrans was 0.02 min-1 in the tumor volume and 0.00 in the normal white matter. Conclusion: Our initial results suggest that multiparametric MRI sequences may provide a more quantitative evaluation of vascular and tumor properties. Implementing functional imaging during MR-SIM may be particularly beneficial in assessing tumor extent, differentiating radiation necrosis from tumor recurrence, and establishing reliable

  7. 3T MRI of the knee with optimised isotropic 3D sequences. Accurate delineation of intra-articular pathology without prolonged acquisition times

    Energy Technology Data Exchange (ETDEWEB)

    Abdulaal, Osamah M.; Rainford, Louise; Galligan, Marie; McGee, Allison [University College Dublin, Radiography and Diagnostic Imaging, School of Medicine, Belfield, Dublin (Ireland); MacMahon, Peter; Kavanagh, Eoin [Mater Misericordiae University Hospital, Department of Radiology, Dublin (Ireland); University College Dublin, School of Medicine, Dublin (Ireland); Cashman, James [Mater Misericordiae University Hospital, Department of Orthopaedics, Dublin (Ireland); University College Dublin, School of Medicine, Dublin (Ireland)

    2017-11-15

    To investigate optimised isotropic 3D turbo spin echo (TSE) and gradient echo (GRE)-based pulse sequences for visualisation of articular cartilage lesions within the knee joint. Optimisation of experimental imaging sequences was completed using healthy volunteers (n=16) with a 3-Tesla (3T) MRI scanner. Imaging of patients with knee cartilage abnormalities (n=57) was then performed. Acquired sequences included 3D proton density-weighted (PDW) TSE (SPACE) with and without fat-suppression (FS), and T2*W GRE (TrueFISP) sequences, with acquisition times of 6:51, 6:32 and 5:35 min, respectively. One hundred sixty-one confirmed cartilage lesions were detected and categorised (Grade II n=90, Grade III n=71). The highest sensitivity and specificity for detecting cartilage lesions were obtained with TrueFISP with values of 84.7% and 92%, respectively. Cartilage SNR mean for PDW SPACE-FS was the highest at 72.2. TrueFISP attained the highest CNR means for joint fluid/cartilage (101.5) and joint fluid/ligament (156.5), and the lowest CNR for cartilage/meniscus (48.5). Significant differences were identified across the three sequences for all anatomical structures with respect to SNR and CNR findings (p-value <0.05). Isotropic TrueFISP at 3T, optimised for acquisition time, accurately detects cartilage defects, although it demonstrated the lowest contrast between cartilage and meniscus. (orig.)

  8. Artifact free T2{sup *}-weighted imaging at high spatial resolution using segmented EPI sequences

    Energy Technology Data Exchange (ETDEWEB)

    Heiler, Patrick Michael; Schad, Lothar Rudi [Heidelberg Univ., Mannheim (Germany). Computer Assisted Clinical Medicine; Schmitter, Sebastian [German Cancer Research Center, Heidelberg (Germany). Dept. of Medical Physics in Radiology

    2010-07-01

    The aim of this work was the development of novel measurement techniques that acquire high resolution T2{sup *}-weighted datasets in measurement times as short as possible without suffering from noticeable blurring and ghosting artifacts. Therefore, two new measurement techniques were developed that acquire a smoother k-space than generic multi shot echo planar imaging sequences. One is based on the principle of echo train shifting, the other on the reversed gradient method. Simulations and phantom measurements demonstrate that echo train shifting works properly and reduces artifacts in multi shot echo planar imaging. For maximum SNR-efficiency this technique was further improved by adding a second contrast. Both contrasts can be acquired within a prolongation in measurement time by a factor of 1.5, leading to an SNR increase by approximately {radical}2. Furthermore it is demonstrated that the reversed gradient method remarkably reduces artifacts caused by a discontinuous k-space weighting. Assuming sequence parameters as feasible for fMRI experiments, artifact free T2{sup *}-weighted images with a matrix size of 256 x 256 leading to an in-plane resolution in the submillimeter range can be obtained in about 2 s per slice. (orig.)

  9. Three-dimensional gradient echo versus spin echo sequence in contrast-enhanced imaging of the pituitary gland at 3 T

    Energy Technology Data Exchange (ETDEWEB)

    Kakite, Suguru, E-mail: sugkaki@med.tottori-u.ac.jp [Division of Radiology, Department of Pathophysiological and Therapeutic Science, Faculty of Medicine, Tottori University, 36-1, Nishicho, Yonago 683-8503 (Japan); Fujii, Shinya [Division of Radiology, Department of Pathophysiological and Therapeutic Science, Faculty of Medicine, Tottori University, 36-1, Nishicho, Yonago 683-8503 (Japan); Kurosaki, Masamichi [Department of Neurosurgery, Faculty of Medicine, Tottori University, 36-1, Nishicho, Yonago 683-8503 (Japan); Kanasaki, Yoshiko; Matsusue, Eiji; Kaminou, Toshio; Ogawa, Toshihide [Division of Radiology, Department of Pathophysiological and Therapeutic Science, Faculty of Medicine, Tottori University, 36-1, Nishicho, Yonago 683-8503 (Japan)

    2011-07-15

    Introduction: To clarify whether a three-dimensional-gradient echo (3D-GRE) or spin echo (SE) sequence is more useful for evaluating sellar lesions on contrast-enhanced T1-weighted MR imaging at 3.0 Tesla (T). Methods: We retrospectively assessed contrast-enhanced T1-weighted images using 3D-GRE and SE sequences at 3.0 T obtained from 33 consecutive patients with clinically suspected sellar lesions. Two experienced neuroradiologists evaluated the images qualitatively in terms of the following criteria: boundary edge of the cavernous sinus and pituitary gland, border of sellar lesions, delineation of the optic nerve and cranial nerves within the cavernous sinus, susceptibility and flow artifacts, and overall image quality. Results: At 3.0 T, 3D-GRE provided significantly better images than the SE sequence in terms of the border of sellar lesions, delineation of cranial nerves, and overall image quality; there was no significant difference regarding the boundary edge of the cavernous sinus and pituitary gland. In addition, the 3D-GRE sequence showed fewer pulsation artifacts but more susceptibility artifacts. Conclusion: Our results indicate that 3D-GRE is the more suitable sequence for evaluating sellar lesions on contrast-enhanced T1-weighted imaging at 3.0 T.

  10. Biologically aggressive regions within glioblastoma identified by spin-lock contrast T1 relaxation in the rotating frame (T1ρ MRI

    Directory of Open Access Journals (Sweden)

    Ramon Francisco Barajas, Jr., MD

    2017-12-01

    Full Text Available Spin-lattice relaxation in the rotating frame magnetic resonance imaging allows for the quantitative assessment of spin-lock contrast within tissues. We describe the utility of spin-lattice relaxation in the rotating frame metrics in characterizing glioblastoma biological heterogeneity. A 84-year-old man presented to our institution with a right frontal temporal mass. Prior tissue sampling from a peripheral nonenhancing lesion was nondiagnostic. Stereotactic image-guided tissue sampling of the nonenhancing T2-fluid-attenuated inversion recovery hyperintense region involving the anterior cingulate gyrus with elevated spin-lattice relaxation in the rotating frame metrics provided a pathologic diagnosis of glioblastoma. This case illustrates the utility of spin-lattice relaxation in the rotating frame magnetic resonance imaging in identifying biologically aggressive regions within glioblastoma.

  11. Signatures of a gearwheel quantum spin liquid in a spin-1/2 pyrochlore molybdate Heisenberg antiferromagnet

    Science.gov (United States)

    Iqbal, Yasir; Müller, Tobias; Riedl, Kira; Reuther, Johannes; Rachel, Stephan; Valentí, Roser; Gingras, Michel J. P.; Thomale, Ronny; Jeschke, Harald O.

    2017-12-01

    We theoretically investigate the low-temperature phase of the recently synthesized Lu2Mo2O5N2 material, an extraordinarily rare realization of a S =1 /2 three-dimensional pyrochlore Heisenberg antiferromagnet in which Mo5 + are the S =1 /2 magnetic species. Despite a Curie-Weiss temperature (ΘCW) of -121 (1 ) K, experiments have found no signature of magnetic ordering or spin freezing down to T*≈0.5 K. Using density functional theory, we find that the compound is well described by a Heisenberg model with exchange parameters up to third nearest neighbors. The analysis of this model via the pseudofermion functional renormalization group method reveals paramagnetic behavior down to a temperature of at least T =| ΘCW|/100 , in agreement with the experimental findings hinting at a possible three-dimensional quantum spin liquid. The spin susceptibility profile in reciprocal space shows momentum-dependent features forming a "gearwheel" pattern, characterizing what may be viewed as a molten version of a chiral noncoplanar incommensurate spiral order under the action of quantum fluctuations. Our calculated reciprocal space susceptibility maps provide benchmarks for future neutron scattering experiments on single crystals of Lu2Mo2O5N2 .

  12. Fat suppression with short inversion time inversion-recovery and chemical-shift selective saturation: a dual STIR-CHESS combination prepulse for turbo spin echo pulse sequences.

    Science.gov (United States)

    Tanabe, Koji; Nishikawa, Keiichi; Sano, Tsukasa; Sakai, Osamu; Jara, Hernán

    2010-05-01

    To test a newly developed fat suppression magnetic resonance imaging (MRI) prepulse that synergistically uses the principles of fat suppression via inversion recovery (STIR) and spectral fat saturation (CHESS), relative to pure CHESS and STIR. This new technique is termed dual fat suppression (Dual-FS). To determine if Dual-FS could be chemically specific for fat, the phantom consisted of the fat-mimicking NiCl(2) aqueous solution, porcine fat, porcine muscle, and water was imaged with the three fat-suppression techniques. For Dual-FS and STIR, several inversion times were used. Signal intensities of each image obtained with each technique were compared. To determine if Dual-FS could be robust to magnetic field inhomogeneities, the phantom consisting of different NiCl(2) aqueous solutions, porcine fat, porcine muscle, and water was imaged with Dual-FS and CHESS at the several off-resonance frequencies. To compare fat suppression efficiency in vivo, 10 volunteer subjects were also imaged with the three fat-suppression techniques. Dual-FS could suppress fat sufficiently within the inversion time of 110-140 msec, thus enabling differentiation between fat and fat-mimicking aqueous structures. Dual-FS was as robust to magnetic field inhomogeneities as STIR and less vulnerable than CHESS. The same results for fat suppression were obtained in volunteers. The Dual-FS-STIR-CHESS is an alternative and promising fat suppression technique for turbo spin echo MRI. Copyright 2010 Wiley-Liss, Inc.

  13. Intensity of prolactinoma on T2-weighted magnetic resonance imaging: towards another gender difference

    International Nuclear Information System (INIS)

    Kreutz, Julie; Vroonen, Laurent; Petrossians, Patrick; Rostomyan, Liliya; Beckers, Albert; Cattin, Francoise; Thiry, Albert; Tshibanda, Luaba; Bonneville, Jean-Francois

    2015-01-01

    Clinical presentations of prolactinomas are quite different between genders. In comparison with women's prolactinoma, those in men showed predominance of large tumors with high prolactin (PRL) levels. This preponderance could be attributed to a greater proliferative potential of the tumors. Differences in magnetic resonance imaging (MRI) signal at diagnosis have not been yet clearly evaluated. We conduct a retrospective study comparing MRI signal intensity (SI) on T2-weighted images (T2-WI) between 41 men and 41 women to investigate whether or not men prolactinoma present specific features. In addition to the size of the adenoma and PRL levels (P < 0001), prolactinomas in men also exhibit differences from those in women in signal on T2-WI on MRI (P < 0001). Women's prolactinomas are mostly of high SI on T2-WI while men's prolactinomas exhibit a more heterogeneous pattern of SI on T2-WI. Prolactinomas presenting with low SI on T2-WI are almost exclusively encountered in men. Presence of T2-WI hypointensities in pituitary adenoma can be predictive of a different subtype of prolactinoma almost encountered in men and possibly translate the presence of spherical amyloid deposits, in agreement with the literature. (orig.)

  14. Intensity of prolactinoma on T2-weighted magnetic resonance imaging: towards another gender difference

    Energy Technology Data Exchange (ETDEWEB)

    Kreutz, Julie [University Hospital Sart-Tilman, Department of Radiology, Liege (Belgium); Centre Hospitalier Universitaire de Liege, Domaine Universitaire du Sart Tilman, Service d' Imagerie Medicale, Liege (Belgium); Vroonen, Laurent; Petrossians, Patrick; Rostomyan, Liliya; Beckers, Albert [University Hospital Sart-Tilman, Department of Endocrinology, Liege (Belgium); Cattin, Francoise [University Hospital Besancon, Department of Radiology, Besancon (France); Thiry, Albert [University Hospital Sart-Tilman, Department of Pathology, Liege (Belgium); Tshibanda, Luaba [University Hospital Sart-Tilman, Department of Radiology, Liege (Belgium); Bonneville, Jean-Francois [University Hospital Sart-Tilman, Department of Radiology, Liege (Belgium); University Hospital Sart-Tilman, Department of Endocrinology, Liege (Belgium)

    2015-07-15

    Clinical presentations of prolactinomas are quite different between genders. In comparison with women's prolactinoma, those in men showed predominance of large tumors with high prolactin (PRL) levels. This preponderance could be attributed to a greater proliferative potential of the tumors. Differences in magnetic resonance imaging (MRI) signal at diagnosis have not been yet clearly evaluated. We conduct a retrospective study comparing MRI signal intensity (SI) on T2-weighted images (T2-WI) between 41 men and 41 women to investigate whether or not men prolactinoma present specific features. In addition to the size of the adenoma and PRL levels (P < 0001), prolactinomas in men also exhibit differences from those in women in signal on T2-WI on MRI (P < 0001). Women's prolactinomas are mostly of high SI on T2-WI while men's prolactinomas exhibit a more heterogeneous pattern of SI on T2-WI. Prolactinomas presenting with low SI on T2-WI are almost exclusively encountered in men. Presence of T2-WI hypointensities in pituitary adenoma can be predictive of a different subtype of prolactinoma almost encountered in men and possibly translate the presence of spherical amyloid deposits, in agreement with the literature. (orig.)

  15. Spin wave collapse and incommensurate fluctuations in URu2Si2

    DEFF Research Database (Denmark)

    Buyers, W.J.L.; Tun, Z.; Petersen, T.

    1994-01-01

    To test if the T(N) = 17.7 K transition in URu2Si2 is driven by a divergence of a magnetic order parameter we performed high-resolution neutron scattering. At the ordering wave vector the spin-wave energy collapsed. and the susceptibility diverged as T(N) was approached. This confirms that the or...... that the order parameter is the magnetic dipole, as shown by recent symmetry arguments and polarized neutron experiments [1]. We also observe incommensurate fluctuations, suggesting that competing temperature-dependent interactions may influence this weak-moment transition.......To test if the T(N) = 17.7 K transition in URu2Si2 is driven by a divergence of a magnetic order parameter we performed high-resolution neutron scattering. At the ordering wave vector the spin-wave energy collapsed. and the susceptibility diverged as T(N) was approached. This confirms...

  16. SU-E-T-661: Quantitative MRI Assessment of a Novel Direction-Modulated Brachytherapy Tandem Applicator for Cervical Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Soliman, A; Elzibak, A; Fatemi, A; Safigholi, H; Leung, E; Ravi, A; Song, W [Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada); Han, D [Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada); University of California, San Diego, La Jolla, CA (United States)

    2015-06-15

    Purpose: To quantitatively evaluate the MR image quality of a novel direction modulated brachytherapy (DMBT) tandem applicator for cervical cancer, using the clinical MRI scanning protocol for image guided brachytherapy. Methods: The tungsten alloy-based applicator was placed in a water phantom and clinical imaging protocol was performed. Axial images were acquired using 2D turbo-spin echo (TSE) T2-weighted sequence on a 1.5T GE 450w MR scanner and an 8-channel body coil. As multi-channel receiver coil was used, inhomogeneities in the B1 receive field must be considered before performing the quantification process. Therefore the applicator was removed from the phantom and the whole imaging session was performed again for the water phantom with the same parameters. Images from the two scans were then subtracted, resulting in a difference image that only shows the applicator with its surrounding magnetic susceptibility dipole artifact. Line profiles were drawn and plotted on the difference image at various angles and locations along the tandem. Full width at half maximum (FWHM) was measured at all the line profiles to quantify the extent of the artifact. Additionally, the extent of the artifact along the diameter of the tandem was measured at various angles and locations. Results: After removing the background inhomogeneities of the receiver coil, FWHM of the tandem measured 5.75 ± 0.35 mm (the physical tandem diameter is 5.4 mm). The average extent of the artifacts along the diameter of the tandem measured is 2.14 ± 0.56 mm. In contrast to CT imaging of the same applicator (not shown here), the tandem can be easily identified without additional correction algorithms. Conclusion: This work demonstrated that the novel DMBT tandem applicator has minimal susceptibility artifact in T2-weighted images employed in clinical practice for MRI-guided brachytherapy of cervical cancer.

  17. Usefulness of magnetic resonance cholangiography and additional T2-weighted axial image in evaluating focaI intrahepatic ductal dilatation

    International Nuclear Information System (INIS)

    Park, Yeong Mi; Cha, Sung Sook; Lee, Jong Yuk

    2004-01-01

    To evaluate the value of MR cholangiography (MRC) and MRC with additional T2-weighted axial imaging for evaluating the cause and determining the therapeutic plan in patients with a focal dilatation of the intrahepatic bile ducts(IHBD). Forty nine patients (male, 27; female, 22; age range, 12-72 (mean, 51) years) with a focal intrahepatic ductal dilatation confirmed surgically and pathologically (lobectomy, 34; biopsy, 7; surgical finding and T-tube cholangiography, 7; percutaneous transhepatic biliary drainage with bile cytology, 1) underwent MRC and T2-weighted axial imaging. The MRC were obtained in one of two ways (a single slab or multislice acquisition under chemical fat saturation) using RARE (31 patients, source images and single slice images), or TSE (18 patients, source images and MIP reconstruction images). Two radiologists reviewed the MRC images alone, and the MRC images with the T2-weighted axial images. A diagnosis was determined by consensus. In 37 out of 49 patients, the causes of a bile duct dilation were benign diseases (IHBD stones in 33 cases, liver abscesses with IHBD stones in three cases, one inflammatory pseudotumor). Twelve patients had cholangiocarcinomas (mass-forming type in seven cases, intraductal type in three cases, and periductaI infiltrating type in two cases). A correct diagnosis was confirmed in 47 out of 49 cases(96.0%), i.e. all the 37 benign lesions and 10 out of 12 malignant lesions. The addition of the T2-weighted axial image to the MRC did not alter the diagnosis of the causes of the focal intrahepatic ductal dilatation, but was helpful in 10 cases (20.4%). Nine cases (7 cholangiocarcinomas and 2 abscesses), in which MRC showed masses, were visualized more definitely on the additional T2-weighted axial images to the MRC than on the MRC alone. The remaining cases were hepatolithiasis, where stones could be easily differentiated from air by the air-fluid level on the axial images. MRC is a good diagnostic modality for

  18. MR relaxometry in chronic liver diseases: Comparison of T1 mapping, T2 mapping, and diffusion-weighted imaging for assessing cirrhosis diagnosis and severity

    Energy Technology Data Exchange (ETDEWEB)

    Cassinotto, Christophe, E-mail: christophe.cassinotto@chu-bordeaux.fr [Department of Diagnostic and Interventional Imaging, Hôpital Haut-Lévêque, Centre Hospitalier Universitaire et Université de Bordeaux, 1 Avenue de Magellan, 33604 Pessac (France); INSERM U1053, Université Bordeaux, Bordeaux (France); Feldis, Matthieu, E-mail: matthieu.feldis@chu-bordeaux.fr [Department of Diagnostic and Interventional Imaging, Hôpital Haut-Lévêque, Centre Hospitalier Universitaire et Université de Bordeaux, 1 Avenue de Magellan, 33604 Pessac (France); Vergniol, Julien, E-mail: julien.vergniol@chu-bordeaux.fr [Centre D’investigation de la Fibrose Hépatique, Hôpital Haut-Lévêque, Centre Hospitalier Universitaire de Bordeaux, 1 Avenue de Magellan, 33604 Pessac (France); Mouries, Amaury, E-mail: amaury.mouries@chu-bordeaux.fr [Department of Diagnostic and Interventional Imaging, Hôpital Haut-Lévêque, Centre Hospitalier Universitaire et Université de Bordeaux, 1 Avenue de Magellan, 33604 Pessac (France); Cochet, Hubert, E-mail: hubert.cochet@chu-bordeaux.fr [Department of Diagnostic and Interventional Imaging, Hôpital Haut-Lévêque, Centre Hospitalier Universitaire et Université de Bordeaux, 1 Avenue de Magellan, 33604 Pessac (France); and others

    2015-08-15

    Highlights: • The use of MR to classify cirrhosis in different stages is a new interesting field. • We compared liver and spleen T1 mapping, T2 mapping and diffusion-weighted imaging. • MR relaxometry using liver T1 mapping is accurate for the diagnosis of cirrhosis. • Liver T1 mapping shows that values increase with the severity of cirrhosis. • Diffusion-weighted imaging is less accurate than T1 mapping while T2 mapping is not reliable. - Abstract: Background: MR relaxometry has been extensively studied in the field of cardiac diseases, but its contribution to liver imaging is unclear. We aimed to compare liver and spleen T1 mapping, T2 mapping, and diffusion-weighted MR imaging (DWI) for assessing the diagnosis and severity of cirrhosis. Methods: We prospectively included 129 patients with normal (n = 40) and cirrhotic livers (n = 89) from May to September 2014. Non-enhanced liver T1 mapping, splenic T2 mapping, and liver and splenic DWI were measured and compared for assessing cirrhosis severity using Child-Pugh score, MELD score, and presence or not of large esophageal varices (EVs) and liver stiffness measurements using Fibroscan{sup ®} as reference. Results: Liver T1 mapping was the only variable demonstrating significant differences between normal patients (500 ± 79 ms), Child-Pugh A patients (574 ± 84 ms) and Child-Pugh B/C patients (690 ± 147 ms; all p-values <0.00001). Liver T1 mapping had a significant correlation with Child-Pugh score (Pearson's correlation coefficient of 0.46), MEDL score (0.30), and liver stiffness measurement (0.52). Areas under the receiver operating characteristic curves of liver T1 mapping for the diagnosis of cirrhosis (O.85; 95% confidence intervals (CI), 0.77–0.91), Child-Pugh B/C cirrhosis (0.87; 95%CI, 0.76–0.93), and large EVs (0.75; 95%CI, 0.63–0.83) were greater than that of spleen T2 mapping, liver and spleen DWI (all p-values < 0.01). Conclusion: Liver T1 mapping is a promising new diagnostic

  19. MR relaxometry in chronic liver diseases: Comparison of T1 mapping, T2 mapping, and diffusion-weighted imaging for assessing cirrhosis diagnosis and severity

    International Nuclear Information System (INIS)

    Cassinotto, Christophe; Feldis, Matthieu; Vergniol, Julien; Mouries, Amaury; Cochet, Hubert

    2015-01-01

    Highlights: • The use of MR to classify cirrhosis in different stages is a new interesting field. • We compared liver and spleen T1 mapping, T2 mapping and diffusion-weighted imaging. • MR relaxometry using liver T1 mapping is accurate for the diagnosis of cirrhosis. • Liver T1 mapping shows that values increase with the severity of cirrhosis. • Diffusion-weighted imaging is less accurate than T1 mapping while T2 mapping is not reliable. - Abstract: Background: MR relaxometry has been extensively studied in the field of cardiac diseases, but its contribution to liver imaging is unclear. We aimed to compare liver and spleen T1 mapping, T2 mapping, and diffusion-weighted MR imaging (DWI) for assessing the diagnosis and severity of cirrhosis. Methods: We prospectively included 129 patients with normal (n = 40) and cirrhotic livers (n = 89) from May to September 2014. Non-enhanced liver T1 mapping, splenic T2 mapping, and liver and splenic DWI were measured and compared for assessing cirrhosis severity using Child-Pugh score, MELD score, and presence or not of large esophageal varices (EVs) and liver stiffness measurements using Fibroscan ® as reference. Results: Liver T1 mapping was the only variable demonstrating significant differences between normal patients (500 ± 79 ms), Child-Pugh A patients (574 ± 84 ms) and Child-Pugh B/C patients (690 ± 147 ms; all p-values <0.00001). Liver T1 mapping had a significant correlation with Child-Pugh score (Pearson's correlation coefficient of 0.46), MEDL score (0.30), and liver stiffness measurement (0.52). Areas under the receiver operating characteristic curves of liver T1 mapping for the diagnosis of cirrhosis (O.85; 95% confidence intervals (CI), 0.77–0.91), Child-Pugh B/C cirrhosis (0.87; 95%CI, 0.76–0.93), and large EVs (0.75; 95%CI, 0.63–0.83) were greater than that of spleen T2 mapping, liver and spleen DWI (all p-values < 0.01). Conclusion: Liver T1 mapping is a promising new diagnostic tool for

  20. Image quality and cancer visibility of T2-weighted Magnetic Resonance Imaging of the prostate at 7 Tesla

    International Nuclear Information System (INIS)

    Vos, E.K.; Lagemaat, M.W.; Barentsz, J.O.; Fuetterer, J.J.; Zamecnik, P.; Roozen, H.; Maas, M.C.; Orzada, S.; Bitz, A.K.; Scheenen, T.W.J.

    2014-01-01

    To assess the image quality of T2-weighted (T2w) magnetic resonance imaging of the prostate and the visibility of prostate cancer at 7 Tesla (T). Seventeen prostate cancer patients underwent T2w imaging at 7T with only an external transmit/receive array coil. Three radiologists independently scored images for image quality, visibility of anatomical structures, and presence of artefacts. Krippendorff's alpha and weighted kappa statistics were used to assess inter-observer agreement. Visibility of prostate cancer lesions was assessed by directly linking the T2w images to the confirmed location of prostate cancer on histopathology. T2w imaging at 7T was achievable with 'satisfactory' (3/5) to 'good' (4/5) quality. Visibility of anatomical structures was predominantly scored as 'satisfactory' (3/5) and 'good' (4/5). If artefacts were present, they were mostly motion artefacts and, to a lesser extent, aliasing artefacts and noise. Krippendorff's analysis revealed an α = 0.44 between three readers for the overall image quality scores. Clinically significant cancer lesions in both peripheral zone and transition zone were visible at 7T. T2w imaging with satisfactory to good quality can be routinely acquired, and cancer lesions were visible in patients with prostate cancer at 7T using only an external transmit/receive body array coil. (orig.)